WorldWideScience

Sample records for survey instrument consisting

  1. Measuring teamwork in health care settings: a review of survey instruments.

    Science.gov (United States)

    Valentine, Melissa A; Nembhard, Ingrid M; Edmondson, Amy C

    2015-04-01

    Teamwork in health care settings is widely recognized as an important factor in providing high-quality patient care. However, the behaviors that comprise effective teamwork, the organizational factors that support teamwork, and the relationship between teamwork and patient outcomes remain empirical questions in need of rigorous study. To identify and review survey instruments used to assess dimensions of teamwork so as to facilitate high-quality research on this topic. We conducted a systematic review of articles published before September 2012 to identify survey instruments used to measure teamwork and to assess their conceptual content, psychometric validity, and relationships to outcomes of interest. We searched the ISI Web of Knowledge database, and identified relevant articles using the search terms team, teamwork, or collaboration in combination with survey, scale, measure, or questionnaire. We found 39 surveys that measured teamwork. Surveys assessed different dimensions of teamwork. The most commonly assessed dimensions were communication, coordination, and respect. Of the 39 surveys, 10 met all of the criteria for psychometric validity, and 14 showed significant relationships to nonself-report outcomes. Evidence of psychometric validity is lacking for many teamwork survey instruments. However, several psychometrically valid instruments are available. Researchers aiming to advance research on teamwork in health care should consider using or adapting one of these instruments before creating a new one. Because instruments vary considerably in the behavioral processes and emergent states of teamwork that they capture, researchers must carefully evaluate the conceptual consistency between instrument, research question, and context.

  2. Applications of Calendar Instruments in Social Surveys: a review

    NARCIS (Netherlands)

    Glasner, T.J.; Vaart, van der W.

    2009-01-01

    Retrospective reports in survey interviews and questionnaires are subject to many types of recall error, which affect completeness, consistency, and dating accuracy. Concerns about this problem have led to the development of so-called calendar instruments, or timeline techniques. These aided recall

  3. Lateral Violence in Nursing Survey: Instrument Development and Validation

    Directory of Open Access Journals (Sweden)

    Lynne S. Nemeth

    2017-07-01

    Full Text Available An examination of the psychometric properties of the Lateral Violence in Nursing Survey (LVNS, an instrument previously developed to measure the perceived incidence and severity of lateral violence (LV in the nursing workplace, was carried out. Conceptual clustering and principal components analysis were used with survey responses from 663 registered nurses and ancillary nursing staff in a southeastern tertiary care medical center. Where appropriate, Cronbach’s alpha (α evaluated internal consistency. The prevalence/severity of lateral violence items constitute two distinct subscales (LV by self and others with Cronbach’s alpha of 0.74 and 0.86, respectively. The items asking about potential causes of LV are unidimensional and internally consistent (alpha = 0.77 but there is no conceptually coherent theme underlying the various causes. Respondents rating a potential LV cause as “major” scored higher on both prevalence/severity subscales than those rating it a “minor” cause or not a cause. Subsets of items on the LVNS are internally reliable, supporting construct validity. Revisions of the original LVNS instrument will improve its use in future work.

  4. Calibration of dosemeters and survey instruments for photon

    International Nuclear Information System (INIS)

    Alamares, A.L.; Caseria, E.S.

    1995-01-01

    The Philippine Nuclear Research Institute (PNRI), the country's regulatory agency, through its Radiation Protection Unit of the Nuclear Regulations Licensing and Safeguard Division provides the calibration services of nuclear instruments used by various institutions. The periodic calibration and standardization of radiation and protection survey instruments are done to insure correct and valid radiation readings. It is also a regulatory requirement for radiation workers to use only operable and precalibrated survey instruments for their work with radioactive materials. The PNRI maintains and operates the Secondary Standard Dosimetry Laboratory (SSDL). It provides the periodic calibration and standardization of radiation monitoring and protection survey instruments, and also the radiological hazard and performance evaluation surveys of radiotherapy facilities and others. For the calibration of survey instruments, the standard sources of Cs-137 and Co-60 are used. The calibration procedures for survey meters and pocket dosimeters are explained. The clients served are shown. The personnel dosimetry using film badges, the application of ICRU operational quantities, and the problems encountered and recommendations are reported. (K.I.)

  5. Regulatory requirements on the calibration and use of survey instruments

    International Nuclear Information System (INIS)

    Domondon, D.B.

    1989-01-01

    Regulatory requirements on the provision, calibration and occasions of use of survey instruments are enumerated for a number of licensed activities. Two methods of calibrating survey instruments are described. Factors that must be taken into consideration in conducting calibrations, contents of calibration reports and of the sticker attached to the instrument which are needed for the correct use of the instrument are discussed. The precautions to be observed in order to insure correct use of survey instruments are described. (Auth.)

  6. The Karen instruments for measuring quality of nursing care: construct validity and internal consistency.

    Science.gov (United States)

    Lindgren, Margareta; Andersson, Inger S

    2011-06-01

    Valid and reliable instruments for measuring the quality of care are needed for evaluation and improvement of nursing care. Previously developed and evaluated instruments, the Karen-patient and the Karen-personnel based on Donabedian's Structure-Process-Outcome triad (S-P-O triad) had promising content validity, discriminative power and internal consistency. The objective of this study was to further develop the instruments with regard to construct validity and internal consistency. This prospective study was carried out in medical and surgical wards at a hospital in Sweden. A total of 95 patients and 120 personnel were included. The instruments were tested for construct validity by performing factor analyses in two steps and for internal consistency using Cronbach's alpha coefficient. The first confirmatory factor analyses, with a pre-determined three-factor solution did not load well according to the S-P-O triad, but the second exploratory factor analysis with a six-factor solution appeared to be more coherent and the distribution of variables seemed to be logical. The reliability, i.e. internal consistency, was good in both factor analyses. The Karen-patient and the Karen-personnel instruments have achieved acceptable levels of construct validity. The internal consistency of the instruments is good. This indicates that the instruments may be suitable to use in clinical practice for measuring the quality of nursing care.

  7. Instrument evaluation no. 33. Automess Szintomat 6134 radiation survey meter

    International Nuclear Information System (INIS)

    McClure, D.R.

    1986-04-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This instrument evaluation report deals with the Automess Szintomat 6134 Radiation Survey Meter

  8. International Survey on agriculture-climate change policy instruments

    Energy Technology Data Exchange (ETDEWEB)

    Fernagut, M.; Priem, M.; Sorgeloos, L.

    2011-09-15

    The title study provides an international overview of agriculture-climate change policy instruments for the reduction of methane and nitrous oxide emissions. The aim of this study is to clarify how national and/or international agriculture-climate-policies could or should be instrumented during the coming three to five years to achieve significant emission reductions of methane and nitrous oxide in the Dutch agricultural sector by 2020. The study includes an international survey, a quick-scan inventory of useful and inspiring examples of policy and reduction measures to reduce non CO2 greenhouse gases. ERM used an approach consisting out of three phases. In the first phase countries were selected on the basis of emissions and Kyoto protocol targets. In the second phase policy measures of these countries were listed, based on publicly available national and international sources. In a third phase a sub-set of this selection was analyzed in-depth through communications with local focal points and additional review of policy documents, to enhance the understanding of context, impact and results of each of these policies and measures.

  9. Item-level psychometrics of the ADL instrument of the Korean National Survey on persons with physical disabilities.

    Science.gov (United States)

    Hong, Ickpyo; Lee, Mi Jung; Kim, Moon Young; Park, Hae Yean

    2017-10-01

    The aim of this study is to investigate the psychometrics of the 12 items of an instrument assessing activities of daily living (ADL) using an item response theory model. A total of 648 adults with physical disabilities and having difficulties in ADLs were retrieved from the 2014 Korean National Survey on People with Disabilities. The psychometric testing included factor analysis, internal consistency, precision, and differential item functioning (DIF) across categories including sex, older age, marital status, and physical impairment area. The sample had a mean age of 69.7 years old (SD = 13.7). The majority of the sample had lower extremity impairments (62.0%) and had at least 2.1 chronic conditions. The instrument demonstrated unidimensional construct and good internal consistency (Cronbach's alpha = 0.95). The instrument precisely estimated person measures within a wide range of theta values (-2.22 logits  5.0%). Our findings indicate that the dressing item would need to be modified to improve its psychometrics. Overall, the ADL instrument demonstrates good psychometrics, and thus, it may be used as a standardized instrument for measuring disability in rehabilitation contexts. However, the findings are limited to adults with physical disabilities. Future studies should replicate psychometric testing for survey respondents with other disorders and for children.

  10. Digital readout alpha survey instrument

    International Nuclear Information System (INIS)

    Jacobs, M.E.

    1976-01-01

    A prototype solid-state digital readout alpha particle survey instrument has been designed and constructed. The meter incorporates a Ludlum alpha scintillator as a detector, digital logic circuits for control and timing, and a Digilin counting module with reflective liquid crystal display. The device is used to monitor alpha radiation from a surface. Sample counts are totalized over 10-second intervals and displayed digitally in counts per minute up to 19,999. Tests over source samples with counts to 15,600 cpm have shown the device to be rapid, versatile and accurate. The instrument can be fabricated in one man-week and requires about $835 in material costs. A complete set of drawings is included

  11. Instrument and Survey Analysis Technical Report: Program Implementation Survey. Technical Report #1112

    Science.gov (United States)

    Alonzo, Julie; Tindal, Gerald

    2011-01-01

    This technical document provides guidance to educators on the creation and interpretation of survey instruments, particularly as they relate to an analysis of program implementation. Illustrative examples are drawn from a survey of educators related to the use of the easyCBM learning system. This document includes specific sections on…

  12. Technical evaluation of available state of Nevada survey instruments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-02-01

    Argonne National Laboratory (ANL) is reviewing the survey research studies completed by Mountain West Research (1987-1989) for the state of Nevada`s Nuclear Waste Project Office. In this research, 14 survey instruments were used to seek data on whether perceptions of risk could be associated with the possible siting of a high-level radioactive waste repository in Nevada and could be a dominant source of potential, significant, adverse economic impacts. This report presents results from phase 1 of the review, in which ANL contracted with the National Opinion Research Center (NORC) at the University of Chicago to evaluate the technical merits of the nine survey instruments that ANL had been able to acquire. The scope of NORC`s work was limited to rating the questions and stating their strengths and weaknesses. NORC concluded that the surveys could provide valuable data about risk perceptions and potential behavioral responses. NORC identified a few minor problems with a number of questions and the calculated response rates but claimed these problems would probably not have any major biasing effect. The NORC evaluation would have been more complete if the terms used in the questionnaires had been defined, all survey instruments had been acquired, and all data had been made available to the public.

  13. Technical evaluation of available state of Nevada survey instruments

    International Nuclear Information System (INIS)

    1993-02-01

    Argonne National Laboratory (ANL) is reviewing the survey research studies completed by Mountain West Research (1987-1989) for the state of Nevada's Nuclear Waste Project Office. In this research, 14 survey instruments were used to seek data on whether perceptions of risk could be associated with the possible siting of a high-level radioactive waste repository in Nevada and could be a dominant source of potential, significant, adverse economic impacts. This report presents results from phase 1 of the review, in which ANL contracted with the National Opinion Research Center (NORC) at the University of Chicago to evaluate the technical merits of the nine survey instruments that ANL had been able to acquire. The scope of NORC's work was limited to rating the questions and stating their strengths and weaknesses. NORC concluded that the surveys could provide valuable data about risk perceptions and potential behavioral responses. NORC identified a few minor problems with a number of questions and the calculated response rates but claimed these problems would probably not have any major biasing effect. The NORC evaluation would have been more complete if the terms used in the questionnaires had been defined, all survey instruments had been acquired, and all data had been made available to the public

  14. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    Energy Technology Data Exchange (ETDEWEB)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides. (JGB)

  15. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    International Nuclear Information System (INIS)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides

  16. Survey of beam instrumentation used in SLC

    International Nuclear Information System (INIS)

    Ecklund, S.D.

    1991-03-01

    A survey of beam instruments used at SLAC in the SLC machine is presented. The basic utility and operation of each device is briefly described. The various beam instruments used at the Stanford Linear Collider (SLC), can be classified by the function they perform. Beam intensity, position and size are typical of the parameters of beam which are measured. Each type of parameter is important for adjusting or tuning the machine in order to achieve optimum performance. 39 refs

  17. International Energy Agency instrumented facilities survey for solar assisted low energy dwellings

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-02-01

    Compiled are surveys outlining the instrumentation of 38 active and passive solar projects in 9 countries (Denmark, Italy, Japan, Netherlands, Sweden, Switzerland, United Kingdom, United States, and West Germany). After the surveys themselves are presented, the data are rearranged to compare answers from similar survey questions for each of the projects. These questions address building, solar system and instrumentation descriptions and meteorological, solar system and building system instrumentatation capabilities. (LEW)

  18. Measuring determinants of career satisfaction of anesthesiologists: validation of a survey instrument.

    Science.gov (United States)

    Afonso, Anoushka M; Diaz, James H; Scher, Corey S; Beyl, Robbie A; Nair, Singh R; Kaye, Alan David

    2013-06-01

    To measure the parameter of job satisfaction among anesthesiologists. Survey instrument. Academic anesthesiology departments in the United States. 320 anesthesiologists who attended the annual meeting of the ASA in 2009 (95% response rate). The anonymous 50-item survey collected information on 26 independent demographic variables and 24 dependent ranked variables of career satisfaction among practicing anesthesiologists. Mean survey scores were calculated for each demographic variable and tested for statistically significant differences by analysis of variance. Questions within each domain that were internally consistent with each other within domains were identified by Cronbach's alpha ≥ 0.7. P-values ≤ 0.05 were considered statistically significant. Cronbach's alpha analysis showed strong internal consistency for 10 dependent outcome questions in the practice factor-related domain (α = 0.72), 6 dependent outcome questions in the peer factor-related domain (α = 0.71), and 8 dependent outcome questions in the personal factor-related domain (α = 0.81). Although age was not a variable, full-time status, early satisfaction within the first 5 years of practice, working with respected peers, and personal choice factors were all significantly associated with anesthesiologist job satisfaction. Improvements in factors related to job satisfaction among anesthesiologists may lead to higher early and current career satisfaction. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Study Abroad Survey Instruments: A Comparison of Survey Types and Experiences

    Science.gov (United States)

    Durrant, Marie Bradshaw; Dorius, Cassandra Rasmussen

    2007-01-01

    This study examines different survey instruments used to assess the experiences of U.S. study abroad participants. The intended audience is international and area study practitioners interested in assessing study abroad programs through postprogram interviews. An interview with the top 20 universities for number of students sent on study abroad…

  20. Proceedings of the workshop on radiation survey instruments and calibrations

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Vallario, E.J.; Murphy, B.L.

    1985-11-01

    The workshop was held to discuss two topics: first, a performance standard for radiation survey instruments and the potential for a testing program based on that standard; and second, a system of secondary standards laboratories to provide instrument calibrations and related services. Separate abstracts have been prepared for the individual presentations

  1. A Survey on Nickel Titanium Rotary Instruments and their Usage Techniques by Endodontists in India.

    Science.gov (United States)

    Patil, Thimmanagowda N; Saraf, Prahlad A; Penukonda, Raghavendra; Vanaki, Sneha S; Kamatagi, Laxmikant

    2017-05-01

    The preference and usage of nickel titanium rotary instruments varies from individual to individual based on their technique, experience with the rotary systems and the clinical situation. Very limited information is available to explain the adoption of changing concepts with respect to nickel titanium rotary instruments pertaining to the endodontists in India. The aim of this study was to conduct a questionnaire survey to acquire the knowledge concerning different NiTi rotary instruments and their usage techniques by endodontists in India. A Survey questionnaire was designed which consisted of 32 questions regarding designation, demographics, experience with rotary instruments, usage of different file systems, usage techniques, frequency of reuse, occurrence of file fracture, reasons and their management was distributed by hand in the national postgraduate convention and also disseminated via electronic medium to 400 and 600 endodontists respectively. Information was collected from each individual to gain insight into the experiences and beliefs of endodontists concerning the new endodontic technology of rotary NiTi instrumentation based on their clinical experience with the rotary systems. The questions were designed to ascertain the problems, patterns of use and to identify areas of perceived or potential concern regarding the rotary instruments and the data acquired was statistically evaluated using Fisher's-exact test and the Chi-Square test. Overall 63.8% (638) endodontists responded. ProTaper was one of the most commonly used file system followed by M two and ProTaper Next. There was a significant co relation between the years of experience and the file re use frequency, preparation technique, file separation, management of file separation. A large number of Endodontists prefer to reuse the rotary NiTi instruments. As there was an increase in the experience, the incidence of file separation reduced with increasing number of re use frequency and with

  2. Instrumental motives in negative emotion regulation in daily life: Frequency, consistency, and predictors.

    Science.gov (United States)

    Kalokerinos, Elise K; Tamir, Maya; Kuppens, Peter

    2017-06-01

    People regulate their emotions not only for hedonic reasons but also for instrumental reasons, to attain the potential benefits of emotions beyond pleasure and pain. However, such instrumental motives have rarely been examined outside the laboratory as they naturally unfold in daily life. To assess whether and how instrumental motives operate outside the laboratory, it is necessary to examine them in response to real and personally relevant stimuli in ecologically valid contexts. In this research, we assessed the frequency, consistency, and predictors of instrumental motives in negative emotion regulation in daily life. Participants (N = 114) recalled the most negative event of their day each evening for 7 days and reported their instrumental motives and negative emotion goals in that event. Participants endorsed performance motives in approximately 1 in 3 events and social, eudaimonic, and epistemic motives in approximately 1 in 10 events. Instrumental motives had substantially higher within- than between-person variance, indicating that they were context-dependent. Indeed, although we found few associations between instrumental motives and personality traits, relationships between instrumental motives and contextual variables were more extensive. Performance, social, and epistemic motives were each predicted by a unique pattern of contextual appraisals. Our data demonstrate that instrumental motives play a role in daily negative emotion regulation as people encounter situations that pose unique regulatory demands. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  3. Chemical ionisation mass spectrometry: a survey of instrument technology

    International Nuclear Information System (INIS)

    Mather, R.E.; Todd, J.F.J.

    1979-01-01

    The purpose of this review is to survey the innovations and improvements which have been made in both instrumentation and methodology in chemical ionization mass spectrometry in the past ten years. (Auth.)

  4. Practical implications of neutron survey instrument performance

    International Nuclear Information System (INIS)

    Tanner, R. J.; Bartlett, D. T.; Hager, I. G.; Jones, I. N.; Molinos, C.; Roberts, N. J.; Taylor, G. C.; Thomas, D. J.

    2004-01-01

    Improvements have been made to the Monte Carlo modelling used to calculate the response of the neutron survey instruments most commonly used in the UK, for neutron energies up to 20 MeV. The improved modelling of the devices includes the electronics and battery pack, allowing better calculations of both the energy and angle dependence of response. These data are used to calculate the response of the instruments in rotationally and fully isotropic, as well as unidirectional fields. Experimental measurements with radionuclide sources and monoenergetic neutron fields have been, and continue to be made, to test the calculated response characteristics. The enhancements to the calculations have involved simulation of the sensitivity of the response to variations in instrument manufacture, and will include the influence of the user and floor during measurements. The practical implications of the energy and angle dependence of response, variations in manufacture, and the influence of the user are assessed by folding the response characteristics with workplace energy and direction distributions. (authors)

  5. Comparing NICU teamwork and safety climate across two commonly used survey instruments.

    Science.gov (United States)

    Profit, Jochen; Lee, Henry C; Sharek, Paul J; Kan, Peggy; Nisbet, Courtney C; Thomas, Eric J; Etchegaray, Jason M; Sexton, Bryan

    2016-12-01

    Measurement and our understanding of safety culture are still evolving. The objectives of this study were to assess variation in safety and teamwork climate and in the neonatal intensive care unit (NICU) setting, and compare measurement of safety culture scales using two different instruments (Safety Attitudes Questionnaire (SAQ) and Hospital Survey on Patient Safety Culture (HSOPSC)). Cross-sectional survey study of a voluntary sample of 2073 (response rate 62.9%) health professionals in 44 NICUs. To compare survey instruments, we used Spearman's rank correlation coefficients. We also compared similar scales and items across the instruments using t tests and changes in quartile-level performance. We found significant variation across NICUs in safety and teamwork climate scales of SAQ and HSOPSC (pteamwork scales (teamwork climate and teamwork within units) of the two instruments correlated strongly (safety r=0.72, pteamwork r=0.67, p<0.001). However, the means and per cent agreements for all scale scores and even seemingly similar item scores were significantly different. In addition, comparisons of scale score quartiles between the two instruments revealed that half of the NICUs fell into different quartiles when translating between the instruments. Large variation and opportunities for improvement in patient safety culture exist across NICUs. Important systematic differences exist between SAQ and HSOPSC such that these instruments should not be used interchangeably. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  6. Measurements with the new PHE neutron survey instrument

    International Nuclear Information System (INIS)

    Eakins, J.S.; Tanner, R.J.; Hager, L.G.

    2014-01-01

    A novel design of survey instrument has been developed to accurately estimate ambient dose equivalent from neutrons with energies in the range from thermal to 20 MeV. The device features moderating and attenuating layers to ease measurement of fast and intermediate energy neutrons, combined with guides that channel low-energy neutrons to the single, central detector. A prototype of this device has been constructed and exposed to a set of calibration fields: the resulting measured responses are presented and discussed here, and compared against Monte Carlo data. A simple simulated workplace neutron field has also been developed to test the device. Measured response data have been determined for a prototype design of neutron survey instrument, using facilities at PHE and NPL. In general, the results demonstrated good directional invariance and agreed well with data obtained by Monte Carlo modelling, raising confidence in the accuracy of the response characteristics expected for the device. A simple simulated workplace field has also been developed and characterised, and the performance of the device assessed in it: agreement between measured and modelled results suggests that the device would behave as anticipated in real workplace fields. These performances will be investigated further in the future, as the design makes the transition from a research prototype to a commercially available instrument. (authors)

  7. Principles of survey development for telemedicine applications.

    Science.gov (United States)

    Demiris, George

    2006-01-01

    Surveys can be used in the evaluation of telemedicine applications but they must be properly designed, consistent and accurate. The purpose of the survey and the resources available will determine the extent of testing that a survey instrument should undergo prior to its use. The validity of an instrument is the correspondence between what is being measured and what was intended to be measured. The reliability of an instrument describes the 'consistency' or 'repeatability' of the measurements made with it. Survey instruments should be designed and tested following basic principles of survey development. The actual survey administration also requires consideration, for example data collection and processing, as well as the interpretation of the findings. Surveys are of two different types. Either they are self-administered, or they are administered by interview. In the latter case, they may be administered by telephone or in a face-to-face meeting. It is important to design a survey instrument based on a detailed definition of what it intends to measure and to test it before administering it to the larger sample.

  8. [French residents' training in instrumental deliveries: A national survey].

    Science.gov (United States)

    Saunier, C; Raimond, E; Dupont, A; Pelissier, A; Bonneau, S; Gabriel, R; Graesslin, O

    2016-11-01

    To evaluate French residents in Obstetrics and Gynaecology's training in instrumental deliveries in 2015. We conducted a national descriptive survey among 758 residents between December 2014 and January 2015. Respondents were invited by email to specify their University Hospital, their current university term, the number of instrumental deliveries performed by vacuum extractor, forceps or spatulas, and whether they made systematic ultrasound exams before performing the extraction. Response rate was 34.7 % (n=263). There were important differences between regions in terms of type of instruments used. Vacuum extractor was the most commonly used instrument for instrumental deliveries by French residents (56.9 %), more than forceps (25.2 %) and spatulas (17.9 %). At the end of the residency, all the residents had been trained in instrumental deliveries with at least two instruments. The training of difficult techniques as well as their perfect control is required for instrumental deliveries. Yet, we are forced to note that there are substantial differences in the French residents' training in instrumental deliveries depending on their region. So, teaching at least two techniques seems essential as well as improving the training capacities and standardizing practices. A greater systematization of the teaching of the mechanics and obstetric techniques might be a solution to be considered too. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  9. Reliability and Validity of Survey Instruments to Measure Work-Related Fatigue in the Emergency Medical Services Setting: A Systematic Review.

    Science.gov (United States)

    Patterson, P Daniel; Weaver, Matthew D; Fabio, Anthony; Teasley, Ellen M; Renn, Megan L; Curtis, Brett R; Matthews, Margaret E; Kroemer, Andrew J; Xun, Xiaoshuang; Bizhanova, Zhadyra; Weiss, Patricia M; Sequeira, Denisse J; Coppler, Patrick J; Lang, Eddy S; Higgins, J Stephen

    2018-02-15

    This study sought to systematically search the literature to identify reliable and valid survey instruments for fatigue measurement in the Emergency Medical Services (EMS) occupational setting. A systematic review study design was used and searched six databases, including one website. The research question guiding the search was developed a priori and registered with the PROSPERO database of systematic reviews: "Are there reliable and valid instruments for measuring fatigue among EMS personnel?" (2016:CRD42016040097). The primary outcome of interest was criterion-related validity. Important outcomes of interest included reliability (e.g., internal consistency), and indicators of sensitivity and specificity. Members of the research team independently screened records from the databases. Full-text articles were evaluated by adapting the Bolster and Rourke system for categorizing findings of systematic reviews, and the rated data abstracted from the body of literature as favorable, unfavorable, mixed/inconclusive, or no impact. The Grading of Recommendations, Assessment, Development and Evaluation (GRADE) methodology was used to evaluate the quality of evidence. The search strategy yielded 1,257 unique records. Thirty-four unique experimental and non-experimental studies were determined relevant following full-text review. Nineteen studies reported on the reliability and/or validity of ten different fatigue survey instruments. Eighteen different studies evaluated the reliability and/or validity of four different sleepiness survey instruments. None of the retained studies reported sensitivity or specificity. Evidence quality was rated as very low across all outcomes. In this systematic review, limited evidence of the reliability and validity of 14 different survey instruments to assess the fatigue and/or sleepiness status of EMS personnel and related shift worker groups was identified.

  10. A survey on the VXIbus and validity analyses for instrumentation and control in NPPs

    International Nuclear Information System (INIS)

    Kwon, Kee Choon; Park, Won Man

    1997-06-01

    This document presents the technical status of the VXIbus system and its interface. VMEbus, while developed as a backplane for Motorola processors, can be used for data acquisition, control and other instrumentation applications. The VXIbus and its associated standard for form, fit, and electrical interface have simplified the process of putting together automated instrumentation systems. The VXIplug and play system alliance was founded in 1993, the alliance's charter to improve the effectiveness of VXI-based solutions by increasing ease-of-use and improving the interoperability of mainframes, computers, instrumentations, and software through open, multivendor standards and practices. This technical report surveys surveys the instrumentation and control in NPPs apply to the VXI-based instruments which are studied expendability, interoperability, maintainability and other features. (author). 10 refs., 4 tabs., 25 figs

  11. Assessing the Learning Environment for Medical Students: An Evaluation of a Novel Survey Instrument in Four Medical Schools.

    Science.gov (United States)

    Pololi, Linda H; Evans, Arthur T; Nickell, Leslie; Reboli, Annette C; Coplit, Lisa D; Stuber, Margaret L; Vasiliou, Vasilia; Civian, Janet T; Brennan, Robert T

    2017-06-01

    A practical, reliable, and valid instrument is needed to measure the impact of the learning environment on medical students' well-being and educational experience and to meet medical school accreditation requirements. From 2012 to 2015, medical students were surveyed at the end of their first, second, and third year of studies at four medical schools. The survey assessed students' perceptions of the following nine dimensions of the school culture: vitality, self-efficacy, institutional support, relationships/inclusion, values alignment, ethical/moral distress, work-life integration, gender equity, and ethnic minority equity. The internal reliability of each of the nine dimensions was measured. Construct validity was evaluated by assessing relationships predicted by our conceptual model and prior research. Assessment was made of whether the measurements were sensitive to differences over time and across institutions. Six hundred and eighty-six students completed the survey (49 % women; 9 % underrepresented minorities), with a response rate of 89 % (range over the student cohorts 72-100 %). Internal consistency of each dimension was high (Cronbach's α 0.71-0.86). The instrument was able to detect significant differences in the learning environment across institutions and over time. Construct validity was supported by demonstrating several relationships predicted by our conceptual model. The C-Change Medical Student Survey is a practical, reliable, and valid instrument for assessing the learning environment of medical students. Because it is sensitive to changes over time and differences across institution, results could potentially be used to facilitate and monitor improvements in the learning environment of medical students.

  12. Human factors survey of advanced instrumentation and controls

    International Nuclear Information System (INIS)

    Carter, R.J.

    1989-01-01

    A survey oriented towards identifying the human factors issues in regard to the use of advanced instrumentation and controls (I ampersand C) in the nuclear industry was conducted. A number of United States (US) and Canadian nuclear vendors and utilities were participants in the survey. Human factors items, subsumed under the categories of computer-generated displays (CGD), controls, organizational support, training, and related topics, were discussed. The survey found the industry to be concerned about the human factors issues related to the implementation of advanced I ampersand C. Fifteen potential human factors problems were identified. They include: the need for an advanced I ampersand C guideline equivalent to NUREG-0700; a role change in the control room from operator to supervisor; information overload; adequacy of existing training technology for advanced I ampersand C; and operator acceptance and trust. 11 refs., 1 tab

  13. Developing a Survey Instrument for Evaluating the Effectiveness of Data Management Training Materials

    Science.gov (United States)

    Hou, C. Y.; Soyka, H.; Hutchison, V.; Budden, A. E.

    2016-12-01

    Education and training resources that focus on best practices and guidelines for working with data such as: data management, data sharing, quality metadata creation, and maintenance for reuse, have vital importance not only to the users of Data Observation Network for Earth (DataONE), but also to the broader scientific, research, and academic communities. However, creating and maintaining relevant training/educational materials that remain sensitive and responsive to community needs is dependent upon careful evaluations of the current landscape in order to promote and support thoughtful development of new resources. Using DataONE's existing training/educational resources as the basis for this project, the authors have worked to develop an evaluation instrument that can be used to evaluate the effectiveness of data management training/education resources. The evaluation instrument is in the form of a digital questionnaire/survey. The evaluation instrument also includes the structure and content as recommended by the best practices/guidelines of questionnaire/survey design, based on a review of the literature. Additionally, the evaluation instrument can be customized to evaluate various training/education modalities and be implemented using a web-based questionnaire/survey platform. Finally, the evaluation instrument can be used for site-wide evaluation of DataONE teaching materials and resources, and once made publicly available and openly accessible, other organizations may also utilize the instrument. One key outcome of developing the evaluation instrument is to help in increasing the effectiveness of data management training/education resources across the Earth/Geoscience community. Through this presentation, the authors will provide the full background and motivations for creating an instrument for evaluating the effectiveness of data management training/education resources. The presentation will also discuss in detail the process and results of the current

  14. A Survey Instrument for Measuring the Experiential Value of Employee-Tourist Encounters

    DEFF Research Database (Denmark)

    Mattsson, Jan; Sørensen, Flemming; Jensen, Jens Friis

    In this paper, we develop and test a survey instrument that aims at estimating the experiential value of employee-tourist encounters in destination-based tourism companies, as well as the characteristics of encounters that affect such experiential value. We suggest that such an instrument can...... for their visitors, rather than simply delivering service quality....

  15. OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. I. INSTRUMENT DESCRIPTION AND FIRST RESULTS

    International Nuclear Information System (INIS)

    Horch, Elliott P.; Veillette, Daniel R.; Shah, Sagar C.; O'Rielly, Grant V.; Baena Galle, Roberto; Van Altena, William F.

    2009-01-01

    First results of a new speckle imaging system, the Differential Speckle Survey Instrument, are reported. The instrument is designed to take speckle data in two filters simultaneously with two independent CCD imagers. This feature results in three advantages over other speckle cameras: (1) twice as many frames can be obtained in the same observation time which can increase the signal-to-noise ratio for astrometric measurements, (2) component colors can be derived from a single observation, and (3) the two colors give substantial leverage over atmospheric dispersion, allowing for subdiffraction-limited separations to be measured reliably. Fifty-four observations are reported from the first use of the instrument at the Wisconsin-Indiana-Yale-NOAO 3.5 m Telescope 9 The WIYN Observatory is a joint facility of the University of Wisconsin-Madison, Indiana University, Yale University, and the National Optical Astronomy Observatories. in 2008 September, including seven components resolved for the first time. These observations are used to judge the basic capabilities of the instrument.

  16. A new design of neutron survey instrument

    International Nuclear Information System (INIS)

    Tanner, R.J.; Eakins, J.S.; Hager, L.G.

    2010-01-01

    A novel design of neutron survey instrument has been developed. The moderator has been modified via the use of 'neutron guides', which help thermal neutrons reach the central proportional counter. This innovation has allowed the variations in the energy dependence of ambient dose equivalent response to be reduced compared to prior single-detector designs, whilst maintaining a relatively light moderator and simple construction. In particular, the design has a relatively small over-response to neutrons with energies around 5 keV, when compared to prior designs. The final optimized design has been verified using MCNP5 calculations to ensure that the response is relatively independent of the energy and direction of the incident neutron. This has required the ends of the guides to be structured so that unidirectional and isotropic neutron fields have closely matched responses, as is necessary in the workplace. The reading of the instrument in workplace fields is calculated via folding and the suitability of the design for use in the workplace discussed.

  17. Report of the Survey on the Design Review of New Reactor Applications. Volume 1 - Instrumentation and Control

    International Nuclear Information System (INIS)

    Downey, Steven

    2014-06-01

    At the tenth meeting of the CNRA Working Group on the Regulation of New Reactors (WGRNR) in March 2013, the members agreed to present the responses to the Second Phase, or Design Phase, of the Licensing Process Survey as a multi-volume text. As such, each report will focus on one of the eleven general technical categories covered in the survey. The general technical categories were selected to conform to the topics covered in the International Atomic Energy Agency (IAEA) Safety Guide GS-G-4.1. This report, which is the first volume, provides a discussion of the survey responses related to Instrumentation and Control (I and C). The Instrumentation and Control category includes the twelve following technical topics: Reactor trip system, actuation systems for Engineered Safety Features (ESF), safe shutdown system, safety-related display instrumentation, information and interlock systems important to safety, controls systems, main control room, supplementary control room, diverse I and C systems, data communication systems, software reliability and cyber-security. For each technical topic, the member countries described the information provided by the applicant, the scope and level of detail of the technical review, the technical basis for granting regulatory authorisation, the skill sets required and the Level of effort needed to perform the review. Based on a comparison of the information provided in response to the survey, the following observations were made: - Among the regulatory organisations that responded to the survey, there are similarities in the design information provided by an applicant. In most countries, the design information provided by an applicant includes, but is not limited to, a description of the I and C system design and functions, a description of the verification and validation programmes, and provisions for analysis, testing, and inspection of various I and C systems. - In addition to the regulations, it is a common practice for countries

  18. Human factors survey of advanced instrumentation and controls technologies in nuclear plants

    International Nuclear Information System (INIS)

    Carter, R.J.

    1992-01-01

    A survey of advanced instrumentation and controls (I ampersand C) technologies and associated human factors issues in the US and Canadian nuclear industries was carried out by a team from Oak Ridge national laboratory to provide background for the development of regulatory policy, criteria, and guides for review of advanced I ampersand C systems as well as human engineering guidelines for evaluating these systems. The survey found those components of the US nuclear industry surveyed to be quite interested in advanced I ampersand C, but very cautious in implementing such systems in nuclear facilities and power plants. The trend in the facilities surveyed is to experiment cautiously when there is an intuitive advantage or short-term payoff. In the control room, the usual practice is direct substitution of digital and microprocessor-based instruments or systems that are functionally identical to the analog instruments or systems being replaced. The most advanced I ampersand C systems were found in the Canadian CANDU plants, where the newest plant has digital system in almost 100% of its control systems and in over 70% of its plant protection system. The hypothesis that properly 'introducing digital systems increases safety' is supported by the Canadian experience. The performance of these digital systems was achieved using an appropriate quality assurance program for the software development. The ability of digital systems to detect impending failures and initiate a fail-safe action, is a significant safety issue that should be of special interest to every US utility as well as to the US Nuclear Regulatory Commission. (orig.)

  19. Designing, Testing, and Validating an Attitudinal Survey on an Environmental Topic: A Groundwater Pollution Survey Instrument for Secondary School Students

    Science.gov (United States)

    Lacosta-Gabari, Idoya; Fernandez-Manzanal, Rosario; Sanchez-Gonzalez, Dolores

    2009-01-01

    Research in environmental attitudes' assessment has significantly increased in recent years. The development of specific attitude scales for specific environmental problems has often been proposed. This paper describes the Groundwater Pollution Test (GPT), a 19-item survey instrument using a Likert-type scale. The survey has been used with…

  20. Ethical issues in palliative care for nursing homes: Development and testing of a survey instrument.

    Science.gov (United States)

    Preshaw, Deborah Hl; McLaughlin, Dorry; Brazil, Kevin

    2018-02-01

    To develop and psychometrically assess a survey instrument identifying ethical issues during palliative care provision in nursing homes. Registered nurses and healthcare assistants have reported ethical issues in everyday palliative care provision. Identifying these issues provides evidence to inform practice development to support healthcare workers. Cross-sectional survey of Registered nurses and healthcare assistants in nursing homes in one region of the UK. A survey instrument, "Ethical issues in Palliative Care for Nursing homes", was developed through the findings of qualitative interviews with Registered nurses and healthcare assistants in nursing homes and a literature review. It was reviewed by an expert panel and piloted prior to implementation in a survey in 2015 with a convenience sample of 596 Registered nurses and healthcare assistants. Descriptive and exploratory factor analyses were used to assess the underlying structure of the Frequency and Distress Scales within the instrument. Analysis of 201 responses (response rate = 33.7%) revealed four factors for the Frequency Scale and five factors for the Distress Scale that comprise the Ethical issues in Palliative Care for Nursing homes. Factors common to both scales included "Processes of care," "Resident autonomy" and "Burdensome treatment." Additionally, the Frequency Scale included "Competency," and the Distress Scale included "Quality of care" and "Communication." The Ethical issues in Palliative Care for Nursing homes instrument has added to the palliative care knowledge base by considering the ethical issues experienced specifically by Registered nurses and healthcare assistants within the nursing home. This research offers preliminary evidence of the psychometric properties of the Ethical issues in Palliative Care for Nursing homes survey instrument. The two largest factors highlight the need to address the organisational aspects of caring and provide training in negotiating conflicting

  1. Survey and analysis of radiation safety management systems at medical institutions. Second report. Radiation measurement, calibration of radiation survey meters, and periodic check of installations, equipment, and protection instruments

    International Nuclear Information System (INIS)

    Ohba, Hisateru; Ogasawara, Katsuhiko; Aburano, Tamio

    2006-01-01

    We carried out a questionnaire survey to determine the actual situation of radiation safety management measures in all medical institutions in Japan that had nuclear medicine facilities. The questionnaire consisted of questions concerning the evaluation of shielding capacity; radiation measurement; periodic checks of installations, equipment, and protection instruments; and the calibration of radiation survey meters. The analysis was undertaken according to region, type of establishment, and number of beds. The overall response rate was 60 percent. For the evaluation of shielding capacity, the outsourcing rate was 53 percent of the total. For the radiation measurements of ''leakage radiation dose and radioactive contamination'' and contamination of radioactive substances in the air'', the outsourcing rates were 28 percent and 35 percent of the total, respectively (p<0.001, according to region and establishment). For the periodic check of radiation protection instruments, the implementation rate was 98 percent, and the outsourcing rate was 32 percent for radiation survey meters and 47 percent for lead aprons. The non-implemented rate for calibration of radiation survey meters was 25 percent of the total (p<0.001, according to region and establishment). The outsourcing rate for calibration of radiation survey meters accounted for 87 percent of the total, and of these medical institutions, 72 percent undertook annual calibration. The implementation rate for patient exposure measurement was 20 percent of the total (p<0.001, according to number of beds), and of these medical institutions 46 percent recorded measurement outcome. (author)

  2. Consistency of policy instruments. How the EU could move to a -30% greenhouse gas reduction target

    Energy Technology Data Exchange (ETDEWEB)

    Hoehne, N.; Hagemann, M.; Moltmann, S.; Escalante, D. [Ecofys Germany, Berlin (Germany)

    2011-04-15

    The report provides options for how to achieve a 30% reduction in greenhouse gas emissions, in the EU, from 1990 to 2020. The EU has agreed a set of goals (objectives) and related instruments for 2020. The most significant objectives are the 20% or 30% reduction of greenhouse gases (all emissions, both within and outside the Emissions Trading System), the 20% improvement of energy efficiency and the 20% of renewable energy use by 2020. The stringency of the instruments used to reach these goals, must be set carefully to ensure overall consistency. Particularly after the economic crisis of 2008/2009, the Climate and Energy Package has to be 'tuned' again to be fully consistent, e.g. fast take up of renewable energy and fewer emissions due to the recession may cause an over-allocation in the EU-ETS.

  3. Identifying the Barriers to Using Games and Simulations in Education: Creating a Valid and Reliable Survey Instrument

    Science.gov (United States)

    Justice, Lenora Jean

    2012-01-01

    The purpose of this study was to create a valid and reliable instrument to measure teacher perceived barriers to the adoption of games and simulations in instruction. Previous research, interviews with educators, a focus group, an expert review, and a think aloud protocol were used to design a survey instrument. After finalization, the survey was…

  4. Development and validation of a survey instrument to measure children's advertising literacy

    NARCIS (Netherlands)

    Rozendaal, E.; Opree, S.J.; Buijzen, M.A.

    2016-01-01

    The aim of this study was to develop and validate a survey measurement instrument for children's advertising literacy. Based on the multidimensional conceptualization of advertising literacy by 0056"> Rozendaal, Lapierre, Van Reijmersdal, and Buijzen (2011), 39 items were created to measure two

  5. Status of ART-XC/SRG Instrument

    Science.gov (United States)

    Pavlinsky, M.; Akimov, V.; Levin, V.; Lapshov, I.; Tkachenko, A.; Semena, N.; Buntov, M.; Glushenko, A.; Arefiev, V.; Yaskovich, A.; hide

    2014-01-01

    Spectrum Roentgen Gamma (SRG) is an X-ray astrophysical observatory, developed by Russia in collaboration with Germany. The mission will be launched in March 2016 from Baikonur, by a Zenit rocket with a Fregat booster and placed in a 6-month-period halo orbit around L2. The scientific payload consists of two independent telescopes - a soft-x-ray survey instrument, eROSITA, being provided by Germany and a medium-x-ray-energy survey instrument ART-XC being developed by Russia. ART-XC will consist of seven independent, but co-aligned, telescope modules. The NASA Marshall Space Flight Center (MSFC) is fabricating the flight mirror modules for the ART-XC/SRG. Each mirror module will be aligned with a focal plane CdTe double-sided strip detectors which will operate over the energy range of 6-30 keV, with an angular resolution of less than 1', a field of view of approximately 34' and an expected energy resolution of about 10 percent at 14 keV.

  6. Economic instruments for obesity prevention: results of a scoping review and modified delphi survey

    Directory of Open Access Journals (Sweden)

    LaFrance Jeffrey

    2011-10-01

    Full Text Available Abstract Background Comprehensive, multi-level approaches are required to address obesity. One important target for intervention is the economic domain. The purpose of this study was to synthesize existing evidence regarding the impact of economic policies targeting obesity and its causal behaviours (diet, physical activity, and to make specific recommendations for the Canadian context. Methods Arksey and O'Malley's (2005 methodological framework for conducting scoping reviews was adopted for this study and this consisted of two phases: 1 a structured literature search and review, and 2 consultation with experts in the research field through a Delphi survey and an in-person expert panel meeting in April 2010. Results Two key findings from the scoping review included 1 consistent evidence that weight outcomes are responsive to food and beverage prices. The debate on the use of food taxes and subsidies to address obesity should now shift to how best to address practical issues in designing such policies; and 2 very few studies have examined the impact of economic instruments to promote physical activity and clear policy recommendations cannot be made at this time. Delphi survey findings emphasised the relatively modest impact any specific economic instrument would have on obesity independently. Based on empirical evidence and expert opinion, three recommendations were supported. First, to create and implement an effective health filter to review new and current agricultural polices to reduce the possibility that such policies have a deleterious impact on population rates of obesity. Second, to implement a caloric sweetened beverage tax. Third, to examine how to implement fruit and vegetable subsidies targeted at children and low income households. Conclusions In terms of economic interventions, shifting from empirical evidence to policy recommendation remains challenging. Overall, the evidence is not sufficiently strong to provide clear policy

  7. Development of a Conceptual Model and Survey Instrument to Measure Conscientious Objection to Abortion Provision.

    Directory of Open Access Journals (Sweden)

    Laura Florence Harris

    Full Text Available Conscientious objection to abortion, clinicians' refusal to perform legal abortions because of their religious or moral beliefs, has been the subject of increasing debate among bioethicists, policymakers, and public health advocates in recent years. Conscientious objection policies are intended to balance reproductive rights and clinicians' beliefs. However, in practice, clinician objection can act as a barrier to abortion access-impinging on reproductive rights, and increasing unsafe abortion and related morbidity and mortality. There is little information about conscientious objection from a medical or public health perspective. A quantitative instrument is needed to assess prevalence of conscientious objection and to provide insight on its practice. This paper describes the development of a survey instrument to measure conscientious objection to abortion provision.A literature review, and in-depth formative interviews with stakeholders in Colombia were used to develop a conceptual model of conscientious objection. This model led to the development of a survey, which was piloted, and then administered, in Ghana.The model posits three domains of conscientious objection that form the basis for the survey instrument: 1 beliefs about abortion and conscientious objection; 2 actions related to conscientious objection and abortion; and 3 self-identification as a conscientious objector.The instrument is intended to be used to assess prevalence among clinicians trained to provide abortions, and to gain insight on how conscientious objection is practiced in a variety of settings. Its results can inform more effective and appropriate strategies to regulate conscientious objection.

  8. Calibration of the GNU and HSREM neutron survey instruments

    International Nuclear Information System (INIS)

    Eakins, J.S.; Hager, L.G.; Leake, J.W.; Mason, R.S.; Tanner, R.J.

    2017-01-01

    Two innovative designs of neutron survey instrument have recently been developed to estimate ambient dose equivalent in the workplace: the GNU has an improved energy-independence of response in the meV to TeV range; the HSREM is a comparatively lightweight device covering the meV to 10 MeV range. Both designs offer good detection sensitivity, allowing measurements to be made efficiently and thereby minimizing the exposure to their users. Prototypes of both devices have been constructed and exposed to sets of well-characterized reference fields: the resulting measured responses are presented and discussed here, compared against comprehensive Monte Carlo data.

  9. Calibration of the GNU and HSREM neutron survey instruments

    Energy Technology Data Exchange (ETDEWEB)

    Eakins, J.S., E-mail: jonathan.eakins@phe.gov.uk [Public Health England, CRCE, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom); Hager, L.G. [Public Health England, CRCE, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom); Leake, J.W.; Mason, R.S. [Sherwood Nutec Scientific Ltd., Kent (United Kingdom); Tanner, R.J. [Public Health England, CRCE, Chilton, Didcot, Oxon OX11 0RQ (United Kingdom)

    2017-04-21

    Two innovative designs of neutron survey instrument have recently been developed to estimate ambient dose equivalent in the workplace: the GNU has an improved energy-independence of response in the meV to TeV range; the HSREM is a comparatively lightweight device covering the meV to 10 MeV range. Both designs offer good detection sensitivity, allowing measurements to be made efficiently and thereby minimizing the exposure to their users. Prototypes of both devices have been constructed and exposed to sets of well-characterized reference fields: the resulting measured responses are presented and discussed here, compared against comprehensive Monte Carlo data.

  10. ARABIC TRANSLATION AND ADAPTATION OF THE HOSPITAL CONSUMER ASSESSMENT OF HEALTHCARE PROVIDERS AND SYSTEMS (HCAHPS) PATIENT SATISFACTION SURVEY INSTRUMENT.

    Science.gov (United States)

    Dockins, James; Abuzahrieh, Ramzi; Stack, Martin

    2015-01-01

    To translate and adapt an effective, validated, benchmarked, and widely used patient satisfaction measurement tool for use with an Arabic-speaking population. Translation of survey's items, survey administration process development, evaluation of reliability, and international benchmarking Three hundred-bed tertiary care hospital in Jeddah, Saudi Arabia. 645 patients discharged during 2011 from the hospital's inpatient care units. INTERVENTIONS; The Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) instrument was translated into Arabic, a randomized weekly sample of patients was selected, and the survey was administered via telephone during 2011 to patients or their relatives. Scores were compiled for each of the HCAHPS questions and then for each of the six HCAHPS clinical composites, two non-clinical items, and two global items. Clinical composite scores, as well as the two non-clinical and two global items were analyzed for the 645 respondents. Clinical composites were analyzed using Spearman's correlation coefficient and Cronbach's alpha to demonstrate acceptable internal consistency for these items and scales demonstrated acceptable internal consistency for the clinical composites. (Spearman's correlation coefficient = 0.327 - 0.750, P quarterly to US national averages with results that closely paralleled the US benchmarks. . The Arabic translation and adaptation of the HCAHPS is a valid, reliable, and feasible tool for evaluation and benchmarking of inpatient satisfaction in Arabic speaking populations.

  11. The Dark Energy Survey instrument design

    International Nuclear Information System (INIS)

    Flaugher, B.; Fermilab

    2006-01-01

    We describe a new project, the Dark Energy Survey (DES), aimed at measuring the dark energy equation of state parameter, w, to a statistical precision of ∼5%, with four complementary techniques. The survey will use a new 3 sq. deg. mosaic camera (DECam) mounted at the prime focus of the Blanco 4m telescope at the Cerro-Tololo International Observatory (CTIO). DECam includes a large mosaic camera, a five element optical corrector, four filters (g,r,i,z), and the associated infrastructure for operation in the prime focus cage. The focal plane consists of 62 2K x 4K CCD modules (0.27''/pixel) arranged in a hexagon inscribed within the 2.2 deg. diameter field of view. We plan to use the 250 micron thick fully-depleted CCDs that have been developed at the Lawrence Berkeley National Laboratory (LBNL). At Fermilab, we will establish a packaging factory to produce four-side buttable modules for the LBNL devices, as well as to test and grade the CCDs. R and D is underway and delivery of DECam to CTIO is scheduled for 2009

  12. Construction Of Critical Thinking Skills Test Instrument Related The Concept On Sound Wave

    Science.gov (United States)

    Mabruroh, F.; Suhandi, A.

    2017-02-01

    This study aimed to construct test instrument of critical thinking skills of high school students related the concept on sound wave. This research using a mixed methods with sequential exploratory design, consists of: 1) a preliminary study; 2) design and review of test instruments. The form of test instruments in essay questions, consist of 18 questions that was divided into 5 indicators and 8 sub-indicators of the critical thinking skills expressed by Ennis, with questions that are qualitative and contextual. Phases of preliminary study include: a) policy studies; b) survey to the school; c) and literature studies. Phases of the design and review of test instruments consist of two steps, namely a draft design of test instruments include: a) analysis of the depth of teaching materials; b) the selection of indicators and sub-indicators of critical thinking skills; c) analysis of indicators and sub-indicators of critical thinking skills; d) implementation of indicators and sub-indicators of critical thinking skills; and e) making the descriptions about the test instrument. In the next phase of the review test instruments, consist of: a) writing about the test instrument; b) validity test by experts; and c) revision of test instruments based on the validator.

  13. Consistency of students’ conceptions of wave propagation: Findings from a conceptual survey in mechanical waves

    Directory of Open Access Journals (Sweden)

    Apisit Tongchai

    2011-07-01

    Full Text Available We recently developed a multiple-choice conceptual survey in mechanical waves. The development, evaluation, and demonstration of the use of the survey were reported elsewhere [A. Tongchai et al., Developing, evaluating and demonstrating the use of a conceptual survey in mechanical waves, Int. J. Sci. Educ. 31, 2437 (2009ISEDEB0950-069310.1080/09500690802389605]. We administered the survey to 902 students from seven different groups ranging from high school to second year university. As an outcome of that analysis we were able to identify several conceptual models which the students seemed to be using when answering the questions in the survey. In this paper we attempt to investigate the strength with which the students were committed to these conceptual models, as evidenced by the consistency with which they answered the questions. For this purpose we focus on the patterns of student responses to questions in one particular subtopic, wave propagation. This study has three main purposes: (1 to investigate the consistency of student conceptions, (2 to explore the relative usefulness of different analysis techniques, and (3 to determine what extra information a study of consistency can give about student understanding of basic concepts. We used two techniques: first, categorizing and counting, which is widely used in the science education community, and second, model analysis, recently introduced into physics education research. The manner in which categorizing and counting is used is very diverse while model analysis has been employed only in prescriptive ways. Research studies have reported that students often use their conceptual models inconsistently when solving a series of questions that test the same idea. Our results support their conclusions. Moreover, our findings suggest that students who have had more experiences in physics learning seem to use the scientifically accepted models more consistently. Further, the two analysis techniques

  14. Two new portable survey instruments: the field phoswich detector and the Wee Pee Pee

    International Nuclear Information System (INIS)

    Umbarger, C.J.; Wolf, M.A.

    1978-01-01

    As part of a continuing program to upgrade the health physics survey instrumentation at Los Alamos, we have recently developed two new portable instruments. The first is a fully portable phoswich detector for low energy photons from small amounts of plutonium and americium in the field. The instrument has a background that is 2 to 3 times lower than an equivalent thin NaI detector. The instrument features an aural popper, analogue rate meter, and timer/scaler with liquid crystal display. The second instrument, called the ''Wee Pee Wee,'' is an alpha air proportional probe with complete electronics and readout package mounted on the probe itself. The entire package has a mass of 0.66 kg (1.45 lb) and is carried and operated in one hand. For monitoring shoes and other places where it is difficult to read the count-rate meter, the meter is made detachable for clipping to a shirt pocket, etc. An audio popper, range scales to 100 K cpm, and visual checks for high voltage and battery levels are also included

  15. The ART-XC Instrument on Board the SRG Mission

    Science.gov (United States)

    Pavlinksy, M.; Akimov, V.; Levin, V.; Lapshov, I.; Tkachenko, A.; Semena, N.; Buntov, M.; Glushenko, A.; Arefiev, V.; Yaskovish, A.; hide

    2012-01-01

    Spectrum Roentgen Gamma (SRG) is an X-ray astrophysical observatory, developed by Russia in collaboration with Germany. The mission will be launched in 2014 from Baikonur, by a Zenit rocket with a Fregat booster and placed in a 6-month-period halo orbit around L2. The scientific payload consists of two independent telescopes . a soft-x-ray survey instrument, eROSITA, being provided by Germany and a medium-x-ray-energy survey instrument ART-XC being developed by Russia. ART-XC will consist of seven independent, but co-aligned, telescope modules with seven corresponding cadmium-telluride focal plane detectors. Each will operate over the approximate energy range of 6- 30 keV, with an angular resolution of <1 ', a field of view of 30 ' and an energy resolution about 10% at 14 keV. The NASA Marshall Space Flight Center (MSFC) will fabricate some of the mirror modules, to complement others fabricated by VNIIEF in Russia.

  16. New-generation low-power radiation survey instruments

    International Nuclear Information System (INIS)

    Waechter, D.A.; Bjarke, G.O.; Wolf, M.A.; Trujillo, F.; Umbarger, C.J.

    1983-01-01

    A number of new, ultra-low-powered radiation instruments have recently been developed at Los Alamos. Among these are two instruments which use a novel power source to eliminate costly batteries. The newly developed gamma detecting radiac, nicknamed the Firefly, and the alpha particle detecting instrument, called the Simple Cordless Alpha Monitor, both use recent advances in miniaturization and power-saving electronics to yield devices which are small, rugged, and very power-frugal. The two instruments consume so little power that the need for batteries to run them is eliminated. They are, instead, powered by a charged capacitor which will operate the instruments for an hour or more. Both line power and mechanical sources are used to charge the storage capacitors which power the instruments

  17. New generation low power radiation survey instruments

    International Nuclear Information System (INIS)

    Waechter, D.A.; Bjarke, G.O.; Trujillo, F.; Umbarger, C.J.; Wolf, M.A.

    1984-01-01

    A number of new, ultra-low-powered radiation instruments have recently been developed at Los Alamos. Among these are two instruments which use a novel power source to eliminate costly batteries. The newly developed gamma detecting radiac, nicknamed the Firefly, and the alpha particle detecting instrument, called the Simple Cordless Alpha Monitor, both use recent advances in miniaturization and powersaving electronics to yield devices which are small, rugged, and very power-frugal. The two instruments consume so little power that the need for batteries to run them is eliminated. They are, instead, powered by a charged capacitor which will operate the instruments for an hour or more. Use of a capacitor as a power source eliminates many problems commonly associated with battery-operated instruments, such as having to open the case to change batteries, battery storage life, availability of batteries in the field, and some savings in weight. Both line power and mechanical sources are used to charge the storage capacitors which power the instruments

  18. Design and use of concrete pads for the calibration of radiometric survey instrumentation

    International Nuclear Information System (INIS)

    Loevborg, L.

    1984-10-01

    A gamma-ray spectrometer for use in geological exploration possesses four stripping ratios and three window sensitivities which must be determined to make the instrumentation applicable for field assay or airborne measurement of potassium, uranium, and thorium contents in the ground. Survey organizations in many parts of the world perform the instrument calibration using large pads of concrete which simulate a plane ground of known radioelement concentration. Calibration and monitoring trials with twelve facilities in ten countries prove that moisture absorption, radon exhalation, and particle-size effects can offset a radiometric grade assigned to concrete whose aggregate contains an embedded radioactive mineral. These and other calibration problems are discussed from a combined theoretical and practical viewpoint

  19. Calibrate the aerial surveying instrument by the limited surface source and the single point source that replace the unlimited surface source

    CERN Document Server

    Lu Cun Heng

    1999-01-01

    It is described that the calculating formula and surveying result is found on the basis of the stacking principle of gamma ray and the feature of hexagonal surface source when the limited surface source replaces the unlimited surface source to calibrate the aerial survey instrument on the ground, and that it is found in the light of the exchanged principle of the gamma ray when the single point source replaces the unlimited surface source to calibrate aerial surveying instrument in the air. Meanwhile through the theoretical analysis, the receiving rate of the crystal bottom and side surfaces is calculated when aerial surveying instrument receives gamma ray. The mathematical expression of the gamma ray decaying following height according to the Jinge function regularity is got. According to this regularity, the absorbing coefficient that air absorbs the gamma ray and the detective efficiency coefficient of the crystal is calculated based on the ground and air measuring value of the bottom surface receiving cou...

  20. Worldwide distribution of Total Reflection X-ray Fluorescence instrumentation and its different fields of application: A survey

    Energy Technology Data Exchange (ETDEWEB)

    Klockenkämper, Reinhold, E-mail: reinhold.klockenkaemper@isas.de; Bohlen, Alex von

    2014-09-01

    A survey was carried out with users and manufacturers of Total Reflection X-ray Fluorescence instrumentation in order to demonstrate the worldwide distribution of TXRF equipment and the different fields of applications. In general, TXRF users come from universities and scientific institutes, from working places at synchrotron beam-lines, or laboratories in semiconductor fabs. TXRF instrumentation is distributed in more than 50 countries on six continents and is applied at about 200 institutes and laboratories. The number of running desktop instruments amounts to nearly 300 units. About 60 beamlines run working places dedicated to TXRF. About 300 floor-mounted instruments are estimated to be used in about 150 fabs of the semiconductor industry. In total, 13 different fields of applications could be registered statistically from three different aspects. - Highlights: • According to the survey world maps show the distribution of TXRF equipment. • Nearly 700 individual units are running actually in 57 countries of 6 continents. • Users work at 200 universities, 60 synchrotron-beamlines, and 150 semiconductor fabs. • 13 fields of applications (e.g. environmental, chemical) are evaluated statistically. • Manufacturers, conference members and authors lead to 3 different pie-charts.

  1. K-Band Radio frequency Interference Survey of Southeastern Michigan

    DEFF Research Database (Denmark)

    Curry, Shannon; Ahlers, Michael Faursby; Elliot, Harvey

    2010-01-01

    The Radio frequency Interference Survey of Earth (RISE) is a new type of instrument used to survey and characterize the presence of Radio Frequency Interference (RFI) that can affect microwave radiometers. It consists of a combined microwave radiometer and kurtosis spectrometer with broad frequen...

  2. Mechanical Design of NESSI: New Mexico Tech Extrasolar Spectroscopic Survey Instrument

    Science.gov (United States)

    Santoro, Fernando G.; Olivares, Andres M.; Salcido, Christopher D.; Jimenez, Stephen R.; Jurgenson, Colby A.; Hrynevych, Michael A.; Creech-Eakman, Michelle J.; Boston, Penny J.; Schmidt, Luke M.; Bloemhard, Heather; hide

    2011-01-01

    NESSI: the New Mexico Tech Extrasolar Spectroscopic Survey Instrument is a ground-based multi-object spectrograph that operates in the near-infrared. It will be installed on one of the Nasmyth ports of the Magdalena Ridge Observatory (MRO) 2.4-meter Telescope sited in the Magdalena Mountains, about 48 km west of Socorro-NM. NESSI operates stationary to the telescope fork so as not to produce differential flexure between internal opto-mechanical components during or between observations. An appropriate mechanical design allows the instrument alignment to be highly repeatable and stable for both short and long observation timescales, within a wide-range of temperature variation. NESSI is optically composed of a field lens, a field de-rotator, re-imaging optics, an auto-guider and a Dewar spectrograph that operates at LN2 temperature. In this paper we report on NESSI's detailed mechanical and opto-mechanical design, and the planning for mechanical construction, assembly, integration and verification.

  3. Research in radiation monitoring survey instrumentation. Final report

    International Nuclear Information System (INIS)

    Blalock, T.V.; Kennedy, E.J.; Phillips, R.G.; Walker, E.W. Jr.

    1978-01-01

    Two low-power solid-state prototype readout units were developed, an LED display and a LCD display. This display output was in a bar-graph format, covering four-decades of information, with 10-segments per decade. The displays accept a frequency input, which is standardly available from several portable radiation-survey instruments. Both readout units will operate on two D-cell batteries (3.0 Volt), with a typical current drain requirement of 0.3 MA for the LED display and 30μA for the LCD display. A wide-range electrometer circuit was also developed. The circuit covers an input current range from 10 -13 A to 10 -8 A. The output signal is a pulse whose frequency is directly proportional to input current. The circuit requires no high-megohm resistors, and is autoranging. Several candidate input amplifiers were analyzed and evaluated for use with the electrometer circuit

  4. A Scintillometer Assembly for Geological Survey

    Energy Technology Data Exchange (ETDEWEB)

    Dissing, E; Landstroem, O

    1965-12-15

    An instrument for gamma radiation measurements in connection with geological survey is described. It consists of a scintillation detector with a 5x6 inch sodium iodide crystal and a pulse height analyzer with four independent channels. In field survey work these channels are usually set in fixed positions to record different components of the gamma radiation simultaneously in order to facilitate an identification of the radioactive mineral from which the radiation originates. However, the instrument can also be used for more detailed study of gamma spectra either in the field or in the laboratory. The methods for interpretation of gamma spectra from radioactive ores are briefly reviewed, and a few typical results are given from car-borne and air-borne surveys.

  5. A Scintillometer Assembly for Geological Survey

    International Nuclear Information System (INIS)

    Dissing, E.; Landstroem, O.

    1965-12-01

    An instrument for gamma radiation measurements in connection with geological survey is described. It consists of a scintillation detector with a 5x6 inch sodium iodide crystal and a pulse height analyzer with four independent channels. In field survey work these channels are usually set in fixed positions to record different components of the gamma radiation simultaneously in order to facilitate an identification of the radioactive mineral from which the radiation originates. However, the instrument can also be used for more detailed study of gamma spectra either in the field or in the laboratory. The methods for interpretation of gamma spectra from radioactive ores are briefly reviewed, and a few typical results are given from car-borne and air-borne surveys

  6. Evaluation and Monte Carlo modelling of the response function of the Leake neutron area survey instrument

    International Nuclear Information System (INIS)

    Tagziria, H.; Tanner, R.J.; Bartlett, D.T.; Thomas, D.J.

    2004-01-01

    All available measured data for the response characteristics of the Leake counter have been gathered together. These data, augmented by previously unpublished work, have been compared to Monte Carlo simulations of the instrument's response characteristics in the energy range from thermal to 20 MeV. A response function has been derived, which is recommended as the best currently available for the instrument. Folding this function with workplace energy distributions has enabled an assessment of the impact of this new response function to be made. Similar work, which will be published separately, has been carried out for the NM2 and the Studsvik 2202D neutron area survey instruments

  7. Construct validity and internal consistency in the Leisure Practices Scale (EPL) for adults.

    Science.gov (United States)

    Andrade, Rubian Diego; Schwartz, Gisele Maria; Tavares, Giselle Helena; Pelegrini, Andreia; Teixeira, Clarissa Stefani; Felden, Érico Pereira Gomes

    2018-02-01

    This study proposes and analyzes the construct validity and internal consistency of the Leisure Practices Scale (EPL). This survey seeks to identify the preferences and involvement in in different leisure practices in adults. The instrument was formed based on the cultural leisure content (artistic, manual, physical, sports, intellectual, social, tourist, virtual and contemplation/leisure). The validation process was conducted with: a) content analysis by leisure experts, who evaluated the instrument for clarity of language and practical relevance, which allowed the calculation of the content validity coefficient (CVC); b) reproducibility test-retest with 51 subjects to calculate the temporal variation coefficient; c) internal consistency analysis with 885 participants. The evaluation presented appropriate coefficients, both with respect to language clarity (CVCt = 0.883) and practical relevance (CVCt = 0.879). The reproducibility coefficients were moderate to excellent. The scale showed adequate internal consistency (0.72). The EPL has psychometric quality and acceptable values in its structure, and can be used to investigate adult involvement in leisure activities.

  8. Instrumentation for environmental monitoring: biomedical

    International Nuclear Information System (INIS)

    1979-05-01

    An update is presented to Volume four of the six-volume series devoted to a survey of instruments useful for measurements in biomedicine related to environmental research and monitoring. Results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Methods of detection and analysis of gaseous organic pollutants and metals, including Ni and As are presented. Instrument techniques and notes are included on atomic spectrometry and uv and visible absorption instrumentation

  9. Consistency of students’ conceptions of wave propagation: Findings from a conceptual survey in mechanical waves

    Directory of Open Access Journals (Sweden)

    Chernchok Soankwan

    2011-07-01

    Full Text Available We recently developed a multiple-choice conceptual survey in mechanical waves. The development, evaluation, and demonstration of the use of the survey were reported elsewhere [ A. Tongchai et al. Int. J. Sci. Educ. 31 2437 (2009]. We administered the survey to 902 students from seven different groups ranging from high school to second year university. As an outcome of that analysis we were able to identify several conceptual models which the students seemed to be using when answering the questions in the survey. In this paper we attempt to investigate the strength with which the students were committed to these conceptual models, as evidenced by the consistency with which they answered the questions. For this purpose we focus on the patterns of student responses to questions in one particular subtopic, wave propagation. This study has three main purposes: (1 to investigate the consistency of student conceptions, (2 to explore the relative usefulness of different analysis techniques, and (3 to determine what extra information a study of consistency can give about student understanding of basic concepts. We used two techniques: first, categorizing and counting, which is widely used in the science education community, and second, model analysis, recently introduced into physics education research. The manner in which categorizing and counting is used is very diverse while model analysis has been employed only in prescriptive ways. Research studies have reported that students often use their conceptual models inconsistently when solving a series of questions that test the same idea. Our results support their conclusions. Moreover, our findings suggest that students who have had more experiences in physics learning seem to use the scientifically accepted models more consistently. Further, the two analysis techniques have different advantages and disadvantages. Our findings show that model analysis can be used in more diverse ways, provides

  10. CARMENES instrument overview

    Science.gov (United States)

    Quirrenbach, A.; Amado, P. J.; Caballero, J. A.; Mundt, R.; Reiners, A.; Ribas, I.; Seifert, W.; Abril, M.; Aceituno, J.; Alonso-Floriano, F. J.; Ammler-von Eiff, M.; Antona Jiménez, R.; Anwand-Heerwart, H.; Azzaro, M.; Bauer, F.; Barrado, D.; Becerril, S.; Béjar, V. J. S.; Benítez, D.; Berdiñas, Z. M.; Cárdenas, M. C.; Casal, E.; Claret, A.; Colomé, J.; Cortés-Contreras, M.; Czesla, S.; Doellinger, M.; Dreizler, S.; Feiz, C.; Fernández, M.; Galadí, D.; Gálvez-Ortiz, M. C.; García-Piquer, A.; García-Vargas, M. L.; Garrido, R.; Gesa, L.; Gómez Galera, V.; González Álvarez, E.; González Hernández, J. I.; Grözinger, U.; Guàrdia, J.; Guenther, E. W.; de Guindos, E.; Gutiérrez-Soto, J.; Hagen, H.-J.; Hatzes, A. P.; Hauschildt, P. H.; Helmling, J.; Henning, T.; Hermann, D.; Hernández Castaño, L.; Herrero, E.; Hidalgo, D.; Holgado, G.; Huber, A.; Huber, K. F.; Jeffers, S.; Joergens, V.; de Juan, E.; Kehr, M.; Klein, R.; Kürster, M.; Lamert, A.; Lalitha, S.; Laun, W.; Lemke, U.; Lenzen, R.; López del Fresno, Mauro; López Martí, B.; López-Santiago, J.; Mall, U.; Mandel, H.; Martín, E. L.; Martín-Ruiz, S.; Martínez-Rodríguez, H.; Marvin, C. J.; Mathar, R. J.; Mirabet, E.; Montes, D.; Morales Muñoz, R.; Moya, A.; Naranjo, V.; Ofir, A.; Oreiro, R.; Pallé, E.; Panduro, J.; Passegger, V.-M.; Pérez-Calpena, A.; Pérez Medialdea, D.; Perger, M.; Pluto, M.; Ramón, A.; Rebolo, R.; Redondo, P.; Reffert, S.; Reinhardt, S.; Rhode, P.; Rix, H.-W.; Rodler, F.; Rodríguez, E.; Rodríguez-López, C.; Rodríguez-Pérez, E.; Rohloff, R.-R.; Rosich, A.; Sánchez-Blanco, E.; Sánchez Carrasco, M. A.; Sanz-Forcada, J.; Sarmiento, L. F.; Schäfer, S.; Schiller, J.; Schmidt, C.; Schmitt, J. H. M. M.; Solano, E.; Stahl, O.; Storz, C.; Stürmer, J.; Suárez, J. C.; Ulbrich, R. G.; Veredas, G.; Wagner, K.; Winkler, J.; Zapatero Osorio, M. R.; Zechmeister, M.; Abellán de Paco, F. J.; Anglada-Escudé, G.; del Burgo, C.; Klutsch, A.; Lizon, J. L.; López-Morales, M.; Morales, J. C.; Perryman, M. A. C.; Tulloch, S. M.; Xu, W.

    2014-07-01

    This paper gives an overview of the CARMENES instrument and of the survey that will be carried out with it during the first years of operation. CARMENES (Calar Alto high-Resolution search for M dwarfs with Exoearths with Near-infrared and optical Echelle Spectrographs) is a next-generation radial-velocity instrument under construction for the 3.5m telescope at the Calar Alto Observatory by a consortium of eleven Spanish and German institutions. The scientific goal of the project is conducting a 600-night exoplanet survey targeting ~ 300 M dwarfs with the completed instrument. The CARMENES instrument consists of two separate echelle spectrographs covering the wavelength range from 0.55 to 1.7 μm at a spectral resolution of R = 82,000, fed by fibers from the Cassegrain focus of the telescope. The spectrographs are housed in vacuum tanks providing the temperature-stabilized environments necessary to enable a 1 m/s radial velocity precision employing a simultaneous calibration with an emission-line lamp or with a Fabry-Perot etalon. For mid-M to late-M spectral types, the wavelength range around 1.0 μm (Y band) is the most important wavelength region for radial velocity work. Therefore, the efficiency of CARMENES has been optimized in this range. The CARMENES instrument consists of two spectrographs, one equipped with a 4k x 4k pixel CCD for the range 0.55 - 1.05 μm, and one with two 2k x 2k pixel HgCdTe detectors for the range from 0.95 - 1.7μm. Each spectrograph will be coupled to the 3.5m telescope with two optical fibers, one for the target, and one for calibration light. The front end contains a dichroic beam splitter and an atmospheric dispersion corrector, to feed the light into the fibers leading to the spectrographs. Guiding is performed with a separate camera; on-axis as well as off-axis guiding modes are implemented. Fibers with octagonal cross-section are employed to ensure good stability of the output in the presence of residual guiding errors. The

  11. Personal assistance, income and employment: the spinal injuries survey instrument (SISI) and its application in a sample of people with quadriplegia.

    Science.gov (United States)

    Rowell, D; Connelly, L B

    2008-06-01

    Our aim was to ascertain what effect access to personal care package (PCP) has on the labour market activities of people who have a spinal cord injury (SCI). We developed a new instrument called the spinal injuries survey instrument (SISI). The SISI is a 35-item instrument, which contains items on health, education, employment, along with measures of personal assistance, mobility and psychological attribution style. The SISI was administered, with the Short Form 36 (SF-36) health status instrument, to 250 people with an SCI. The response rate was 72%. A retrospective, matched case-control sampling approach matched individuals who received a PCP, with a cohort who did not. The matching criteria included the site and severity of spinal lesion, age and gender. Although data on the reliability of the instrument are currently lacking, our empirical results are consistent with other studies: (1) mean annual health care costs (AUD$8741) are comparable with Walsh's estimates (2) SF-36 data support Kreuter's contention that mental health is resilient to SCI and (3) a post-injury employment rate of 29.7% corroborates Murphy et al. We present additional data describing income, educational attainment and family support. Our discussion borrows a conceptualization of disability by Sen, that includes both an 'earning handicap' (an impediment to earn income) and a 'conversion handicap' (an impediment to the enjoyment of income). Our application of the SISI provides evidence of both. The labour income of people with quadriplegia is AUD$10,007 per annum, while diminished health status, increased out-of-pocket health expenditure and loss of time suggest a conversion handicap.

  12. Survey of instruments for micrometeorology

    National Research Council Canada - National Science Library

    Monteith, John Lennox

    1972-01-01

    ... have been developed for micrometeorological measurements. Many of these instruments can be used by ecologists to measure and define the environment of plants and animals and to explore the ways in which organisms modify the environment they are exposed...

  13. Instrument evaluation no. 5. Wallac OY universal radiation survey meter type RD-8

    International Nuclear Information System (INIS)

    White, D.F.; Blundell, D.R.; Callowhill, K.; Iles, W.J.

    1976-05-01

    The Wallace RD-8 is a portable, battery-operated survey meter covering an exposure rate range from 0.01 mR/h to 300 R/h. The instrument was designed specifically for military and civil defence applications and is accordingly of particularly rugged construction and claimed to be both waterproof and shockproof. This instrument is unusual in that it has two internally mounted radiation detectors. An end-window GM tube is used to cover the range from 0.01 to 300 mR/h, and a GM tube covers the range from 0.01 to 300 R/h. Both tubes have energy compensation sheaths for the measurement of photon radiation in the forward direction. Only the first tube permits the measurement of β-radiation. The information is given under the following headings; Facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; summary of performance; calibration procedure; conclusions. (U.K.)

  14. Calibrate the aerial surveying instrument by the limited surface source and the single point source that replace the unlimited surface source

    International Nuclear Information System (INIS)

    Lu Cunheng

    1999-01-01

    It is described that the calculating formula and surveying result is found on the basis of the stacking principle of gamma ray and the feature of hexagonal surface source when the limited surface source replaces the unlimited surface source to calibrate the aerial survey instrument on the ground, and that it is found in the light of the exchanged principle of the gamma ray when the single point source replaces the unlimited surface source to calibrate aerial surveying instrument in the air. Meanwhile through the theoretical analysis, the receiving rate of the crystal bottom and side surfaces is calculated when aerial surveying instrument receives gamma ray. The mathematical expression of the gamma ray decaying following height according to the Jinge function regularity is got. According to this regularity, the absorbing coefficient that air absorbs the gamma ray and the detective efficiency coefficient of the crystal is calculated based on the ground and air measuring value of the bottom surface receiving count rate (derived from total receiving count rate of the bottom and side surface). Finally, according to the measuring value, it is proved that imitating the change of total receiving gamma ray exposure rate of the bottom and side surfaces with this regularity in a certain high area is feasible

  15. Automated testing of health physics instruments

    International Nuclear Information System (INIS)

    Swinth, K.L.; Endres, A.W.; Hadley, R.T.; Kenoyer, J.L.

    1983-12-01

    A microcomputer controlled CAMAC system has been adapted for automated testing of health physics survey instruments. Once the survey instrument is positioned, the system automatically performs tests for angular dependence or battery lifetime. Rotation of the instrument is performed by a computer controlled stepping motor while readout is performed by an auto ranging digital volt meter and data stored on computer disks

  16. Marine oil pollution and beached bird surveys: the development of a sensitive monitoring instrument

    International Nuclear Information System (INIS)

    Camphuysen, C.J.; Heubeck, M.

    2001-01-01

    One of the most obvious adverse effects of (chronic) pollution of the world's oceans and seas with mineral oil is the mortality of seabirds. Systematic surveys of beachcast corpses of birds ('beached bird surveys') have been used in many parts of the world to document the effect of oil pollution, but particularly so in Western Europe and in parts of North America. In this paper, the history, current schemes, methods and possible (future) use of beached bird surveys are described and discussed, because the value of beached bird surveys has been hotly disputed. Oil pollution is known since the late 19 th century, while the first beached bird surveys were conducted in the 1920s. Due to the amount of man-power needed for these surveys, most beached bird survey programs thrived only through the work of a large number of volunteers. However, most programs have resulted in substantial amounts of high quality data, often covering many consecutive years. One of the main shortcomings of many beached bird survey programs was the emphasis on stranded bird numbers rather than on relative measures, such as oil rates (percentage of corpses oiled of all corpses found). Sources of pollution, particularly so in chronically polluted regions such as the North Sea, the Baltic, the Mediterranean and the waters around Newfoundland, are insufficiently known, but could be studied through a sampling program connected to beached bird surveys. Suggestions for standardization of methods are presented, which could lead to a global and highly sensitive monitoring instrument of marine oil pollution. (Author)

  17. A 'hybrid' neutron area survey instrument for the determination of neutron dose quantities in the workplace

    International Nuclear Information System (INIS)

    Tanner, R.J.; Jenkins, R.; Lowe, T.; Silvie, J.; Joyce, M.J.; Winsby, A.; Molinos, C.

    2005-01-01

    Full text: Neutron survey instruments are used routinely to determine the dose rates in areas where persons may be occupationally exposed. With a few exceptions, these instruments generally use a proportional counter with a high thermal neutron response located in a moderating sphere of CH 2 . The moderating sphere in such designs contains a thermal neutron absorber to reduce the over-response to thermal and intermediate energy neutrons. However, the commercially available examples of such instruments tend to have strongly energy dependent ambient dose equivalent response characteristics. In particular, they often over-respond in the energy range between 1 eV and 10 keV. A prototype of a novel design has been produced that uses seven detectors located in a moderating sphere of CH 2 , six near the surface to detect thermal and epithermal neutrons, and one in the centre to detect fast neutrons. This has been characterized using a combination of MCNP modelling and measurements to produce an instrument that has improved energy dependence of response characteristics. Additionally, the use of seven detectors offers direction and field hardness information. The design and calibration of the instrument are described and its response in workplaces calculated. (author)

  18. Assessment of instruments in facilitating investment in off-grid renewable energy projects

    International Nuclear Information System (INIS)

    Shi, Xunpeng; Liu, Xiying; Yao, Lixia

    2016-01-01

    Renewable off-grid solution plays a critical role in supporting rural electrification. However, off-grid Renewable Energy (OGRE) project financing faces significant challenges due to limited financing access, low affordability of consumers, high transactions costs and etc. Various supporting instruments have been implemented to facilitate OGRE investment. This study assesses the effectiveness of those instruments with a framework consists of three dimensions: feasibility, sustainability and replicability. The weights of each dimension in the framework and the scores of each instrument are assessed by expert surveys based on the Delphi method. It is suggested that all the three dimensions should be taken into consideration while assessing the instruments, among which feasibility and sustainability are considered as the most important dimensions in the assessment framework. Furthermore, the top-5 most effective instruments in facilitating OGRE investment are local engagement in operation and maintenance, loan guarantee, start-up grant, end user financing, and concessional finance. Developing countries that need to increase electrification, such as most of the ASEAN member states, could use these top scored instruments despite of their limited amount of public finance. - Highlights: •Assess the effectiveness of instruments for promoting financing for OGRE projects. •A three-dimension assessment framework: feasibility, sustainability, replicability. •Use online surveys and the Delphi method to collect experts’ assessment. •The most effective instruments: local engagement, loan guarantee, and start-up grant.

  19. Upward Transfer in STEM Fields of Study: A New Conceptual Framework and Survey Instrument for Institutional Research

    Science.gov (United States)

    Wang, Xueli

    2016-01-01

    This chapter describes a new conceptual framework that informs research on factors influencing transfer in STEM fields of study from 2-year to 4-year institutions, presents a new survey instrument based on the framework, and offers directions for future research in this area.

  20. A frailty instrument for primary care: findings from the Survey of Health, Ageing and Retirement in Europe (SHARE).

    LENUS (Irish Health Repository)

    Romero-Ortuno, Roman

    2010-01-01

    A frailty paradigm would be useful in primary care to identify older people at risk, but appropriate metrics at that level are lacking. We created and validated a simple instrument for frailty screening in Europeans aged ≥50. Our study is based on the first wave of the Survey of Health, Ageing and Retirement in Europe (SHARE, http:\\/\\/www.share-project.org), a large population-based survey conducted in 2004-2005 in twelve European countries.

  1. Inexpensive microwave survey instruments: an evaluation

    International Nuclear Information System (INIS)

    Herman, W.A.; Witters, D.M. Jr.

    1979-11-01

    Instruments were tested. Depending upon the oven modulation and leak location these tests show that the Micromate will yield a warning reading at levels from 0.6 to 1.9 mW/cm 2 , when the effects of modulation sensitivity and polarization ellipticity are considered. It is to be expected, then, that this instrument will yield warning readings even when the oven emission being measured lies well within applicable standards. Its apparent susceptibility to overload damage, however, could decrease its sensitivity with no clue to the user as to what had happened. Given the same considerations and parameters, the tests show that the Guard-Rod will yield a warning reading at levels from 3.7 to 47 mW/cm 2 , depending on which measurement surface is used. This instrument will sometimes yield warnings for oven emissions lying within applicable standards, and sometimes will fail to yield such warnings for emissions 10 times greater than allowable levels. The same considerations show that the Interceptor/Microscan units will light up at levels from as low as 0.7 to 0.8 mW/cm 2 or may require levels of 7 to 9 mW/cm 2 . At levels of 28 to 52 mW/cm 2 or higher, however, the warning LED does not light. If part of the field is cross-polarized, this threshold of extinction may be greater. In any case, there is no apparent way for the user to discern the presence of some potentially hazardous fields, and no way to distinguish such fields from a very low-level field. In summary, instruments of the Interceptor/Microscan design may light up at very low power densities, but fail to light at very high power densities. Clearly, this characteristic is extremely undesirable and potentially dangerous to a user relying on such a device.All of these values assume that the instruments are used in accordance with manufacturer's instructions. Otherwise, results may be worse. Moreover, the range of values given take little or no account of unit-to-unit variation, which may be considerable

  2. Survey and analysis on environmental and electromagnetic effect on instrumentation and control equipment of nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, In Koo; Lee, Dong Young; Cha, Kyung Ho

    2001-03-01

    As the instrumentation and control (I and C) equipment suppliers tend to provide digital components rather than conventional analog type components for instrumentation and control systems of nuclear power plants(NPPs), it is unavoidable to adopt digital equipment for safety I and C systems as well as non-safety systems. However, the full introduction of digital equipment for I and C systems of nuclear power plants raises several concerns which have not been considered in conventional analog I and C equipment. The two major examples of the issues of digital systems are environmental/electromagnetic compatibility (EMC) and software reliability. This report presents the survey and research results on environmental and electromagnetic effect on I and C equipment of nuclear power plants to give a guideline for aging management and design process. Electromagnetic site surveys were conducted to be used as a part of technical basis to demonstrate that I and C systems are compatible with the ambient electromagnetic noise in Korean nuclear power plants.

  3. The Community College Survey of Men: An Initial Validation of the Instrument's Non-Cognitive Outcomes Construct

    Science.gov (United States)

    Wood, J. \\Luke; Harris, Frank, III.

    2013-01-01

    The purpose of this manuscript is to discuss the utility of the Community College Survey of Men (CCSM[c]), an instrument designed to examine predictors of student success for men in community colleges. The authors highlight initial validation results from a recent pilot of the CCSM[c], with a focus on the non-cognitive outcomes construct employed…

  4. Organizational Member Involvement in Physical Activity Coalitions across the United States: Development and Testing of a Novel Survey Instrument for Assessing Coalition Functioning

    Science.gov (United States)

    Bornstein, Daniel B.; Pate, Russell R.; Beets, Michael W.; Saunders, Ruth P.; Blair, Steven N.

    2015-01-01

    Introduction: Coalitions are often composed of member organizations. Member involvement is thought to be associated with coalition success. No instrument currently exists for evaluating organizational member involvement in physical activity coalitions. This study aimed to develop a survey instrument for evaluating organizational member involvement…

  5. A Protocol for Advanced Psychometric Assessment of Surveys

    Science.gov (United States)

    Squires, Janet E.; Hayduk, Leslie; Hutchinson, Alison M.; Cranley, Lisa A.; Gierl, Mark; Cummings, Greta G.; Norton, Peter G.; Estabrooks, Carole A.

    2013-01-01

    Background and Purpose. In this paper, we present a protocol for advanced psychometric assessments of surveys based on the Standards for Educational and Psychological Testing. We use the Alberta Context Tool (ACT) as an exemplar survey to which this protocol can be applied. Methods. Data mapping, acceptability, reliability, and validity are addressed. Acceptability is assessed with missing data frequencies and the time required to complete the survey. Reliability is assessed with internal consistency coefficients and information functions. A unitary approach to validity consisting of accumulating evidence based on instrument content, response processes, internal structure, and relations to other variables is taken. We also address assessing performance of survey data when aggregated to higher levels (e.g., nursing unit). Discussion. In this paper we present a protocol for advanced psychometric assessment of survey data using the Alberta Context Tool (ACT) as an exemplar survey; application of the protocol to the ACT survey is underway. Psychometric assessment of any survey is essential to obtaining reliable and valid research findings. This protocol can be adapted for use with any nursing survey. PMID:23401759

  6. Measuring children's self-reported sport participation, risk perception and injury history: development and validation of a survey instrument.

    Science.gov (United States)

    Siesmaa, Emma J; Blitvich, Jennifer D; White, Peta E; Finch, Caroline F

    2011-01-01

    Despite the health benefits associated with children's sport participation, the occurrence of injury in this context is common. The extent to which sport injuries impact children's ongoing involvement in sport is largely unknown. Surveys have been shown to be useful for collecting children's injury and sport participation data; however, there are currently no published instruments which investigate the impact of injury on children's sport participation. This study describes the processes undertaken to assess the validity of two survey instruments for collecting self-reported information about child cricket and netball related participation, injury history and injury risk perceptions, as well as the reliability of the cricket-specific version. Face and content validity were assessed through expert feedback from primary and secondary level teachers and from representatives of peak sporting bodies for cricket and netball. Test-retest reliability was measured using a sample of 59 child cricketers who completed the survey on two occasions, 3-4 weeks apart. Based on expert feedback relating to face and content validity, modification and/or deletion of some survey items was undertaken. Survey items with low test-retest reliability (κ≤0.40) were modified or deleted, items with moderate reliability (κ=0.41-0.60) were modified slightly and items with higher reliability (κ≥0.61) were retained, with some undergoing minor modifications. This is the first survey of its kind which has been successfully administered to cricketers aged 10-16 years to collect information about injury risk perceptions and intentions for continued sport participation. Implications for its generalisation to other child sport participants are discussed. Copyright © 2010 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  7. Development of a Survey to Assess the Acceptability of an Innovative Contraception Practice among Rural Pharmacists

    Directory of Open Access Journals (Sweden)

    Michael Wong

    2014-03-01

    Full Text Available Improved access to effective contraceptive methods is needed in Canada, particularly in rural areas, where unintended pregnancy rates are high and specific sexual health services may be further away. A rural pharmacist may be the most accessible health care professional. Pharmacy practice increasingly incorporates cognitive services. In Canada many provinces allow pharmacists to independently prescribe for some indications, but not for hormonal contraception. To assess the acceptability for the implementation of this innovative practice in Canada, we developed and piloted a survey instrument. We chose questions to address the components for adoption and change described in Rogers’ “diffusion of innovations” theory. The proposed instrument was iteratively reviewed by 12 experts, then focus group tested among eight pharmacists or students to improve the instrument for face validity, readability, consistency and relevancy to community pharmacists in the Canadian context. We then pilot tested the survey among urban and rural pharmacies. 4% of urban and 35% of rural pharmacies returned pilot surveys. Internal consistency on repeated re-phrased questions was high (Cronbach’s Alpha = 0.901. We present our process for the development of a survey instrument to assess the acceptability and feasibility among Canadian community pharmacists for the innovative practice of the independent prescribing of hormonal contraception.

  8. High School and Beyond. 1980 Senior Coort. Third-Follow-Up (1986). Data File User's Manual. Volume II: Survey Instruments. Contractor Report.

    Science.gov (United States)

    Sebring, Penny; And Others

    Survey instruments used in the collection of data for the High School and Beyond base year (1980) through the third follow-up surveys (1986) are provided as Volume II of a user's manual for the senior cohort data file. The complete user's manual is designed to provide the extensive documentation necessary for using the cohort data files. Copies of…

  9. [Validity of an instrument for assessing food consumption, food habits and cooking skills in 8-11 years old students].

    Science.gov (United States)

    Lera, Lydia; Fretes, Gabriela; González, Carmen Gloria; Salinas, Judith; Vio del Rio, Fernando

    2015-05-01

    An instrument to measure food knowledge, food consumption, cooking skills, food habits and food expenses at school is necessary to assess changes in food practices. To validate an instrument to measure changes in food knowledge, food consumption, cooking skills, food habits and food expenses in Chilean school children 8 - 11 years from third to fifth grade. A validation of a questionnaire with 42 questions was conducted in two stages: the first to assess temporal stability, concordance and internal consistency in 45 children. The second one to apply the survey, modified with the results of the first stage, in 90 children assessing internal consistency. The first survey with 42 questions showed a reasonable temporal stability, concordance and internal consistency for cooking skills, habits and food expenditure at school. Internal consistency was good for food consumption, but not so good for food knowledge. In the final validation with 90 children, there was good consistency for food consumption but bad for food knowledge. Besides, children with cooking skills ate more healthy food and those who expended more money at school, consumed less healthy food. Food knowledge questions were eliminated from the instrument, which was elaborated with 28 questions about food consumption, cooking skills, food habits and food expenses at school. This instrument is useful to assess changes in food and nutrition education interventions in 8 -11 years children, in particular to measure cooking skills and food expenses at school. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  10. Reliability and Validity of Survey Instruments to Measure Work-Related Fatigue in the Emergency Medical Services Setting: A Systematic Review

    Science.gov (United States)

    2018-01-11

    Background: This study sought to systematically search the literature to identify reliable and valid survey instruments for fatigue measurement in the Emergency Medical Services (EMS) occupational setting. Methods: A systematic review study design wa...

  11. Use and maintenance of nuclear medicine instruments in Southeast Asia

    International Nuclear Information System (INIS)

    1983-02-01

    Nuclear medicine instruments are rather sophisticated. They are difficult to maintain in effective working condition, especially in developing countries. The present document describes a survey conducted in Bangladesh, India, Malaysia, Pakistan, Philippines, Singapore, Sri Lanka and Thailand from October 1977 to March 1978, on the use and maintenance of nuclear medicine equipment. The survey evaluated the existing problems of instrument maintenance in the 8 countries visited. The major instruments in use were (1) scintillation probe counters, (2) well scintillation counters and (3) rectilinear cameras. Gamma camera was not widely available in the region at the time of the survey. Most of the surveyed instruments were kept in a detrimental environment resulting in a high failure rate, that caused the relatively high instrument unavailability of 11%. Insufficient bureaucratic handling of repair cases, difficulties with the supply of spare- and replacement parts and lack of training proved to be the main reasons for long periods of instrument inoperation. Remedial actions, based on the survey data, have been initiated

  12. The Therapeutic Environment Screening Survey for Nursing Homes (TESS-NH): an observational instrument for assessing the physical environment of institutional settings for persons with dementia.

    Science.gov (United States)

    Sloane, Philip D; Mitchell, C Madeline; Weisman, Gerald; Zimmerman, Sheryl; Foley, Kristie M Long; Lynn, Mary; Calkins, Margaret; Lawton, M Powell; Teresi, Jeanne; Grant, Leslie; Lindeman, David; Montgomery, Rhonda

    2002-03-01

    To develop an observational instrument that describes the ability of physical environments of institutional settings to address therapeutic goals for persons with dementia. A National Institute on Aging workgroup identified and subsequently revised items that evaluated exit control, maintenance, cleanliness, safety, orientation/cueing, privacy, unit autonomy, outdoor access, lighting, noise, visual/tactile stimulation, space/seating, and familiarity/homelikeness. The final instrument contains 84 discrete items and one global rating. A summary scale, the Special Care Unit Environmental Quality Scale (SCUEQS), consists of 18 items. Lighting items were validated using portable light meters. Concurrent criterion validation compared SCUEQS scores with the Professional Environmental Assessment Protocol (PEAP). Interrater kappa statistics for 74% of items were above.60. For another 10% of items, kappas could not be calculated due to empty cells, but interrater agreement was above 80%. The SCUEQS demonstrated an interrater reliability of.93, a test--retest reliability of.88, and an internal consistency of.81--.83. Light meter ratings correlated significantly with the Therapeutic Environment Screening Survey for Nursing Homes (TESS-NH) lighting items (r =.29--.38, p =.01--.04), and the SCUEQS correlated significantly with global PEAP ratings (r =.52, p TESS-NH efficiently assesses discrete elements of the physical environment and has strong reliability and validity. The SCUEQS provides a quantitative measure of environmental quality in institutional settings.

  13. Development and validation of an instrument to measure nurse educator perceived confidence in clinical teaching.

    Science.gov (United States)

    Nguyen, Van N B; Forbes, Helen; Mohebbi, Mohammadreza; Duke, Maxine

    2017-12-01

    Teaching nursing in clinical environments is considered complex and multi-faceted. Little is known about the role of the clinical nurse educator, specifically the challenges related to transition from clinician, or in some cases, from newly-graduated nurse to that of clinical nurse educator, as occurs in developing countries. Confidence in the clinical educator role has been associated with successful transition and the development of role competence. There is currently no valid and reliable instrument to measure clinical nurse educator confidence. This study was conducted to develop and psychometrically test an instrument to measure perceived confidence among clinical nurse educators. A multi-phase, multi-setting survey design was used. A total of 468 surveys were distributed, and 363 were returned. Data were analyzed using exploratory and confirmatory factor analyses. The instrument was successfully tested and modified in phase 1, and factorial validity was subsequently confirmed in phase 2. There was strong evidence of internal consistency, reliability, content, and convergent validity of the Clinical Nurse Educator Skill Acquisition Assessment instrument. The resulting instrument is applicable in similar contexts due to its rigorous development and validation process. © 2017 The Authors. Nursing & Health Sciences published by John Wiley & Sons Australia, Ltd.

  14. New instrument for measuring student beliefs about physics and learning physics: The Colorado Learning Attitudes about Science Survey

    Science.gov (United States)

    Adams, W. K.; Perkins, K. K.; Podolefsky, N. S.; Dubson, M.; Finkelstein, N. D.; Wieman, C. E.

    2006-06-01

    The Colorado Learning Attitudes about Science Survey (CLASS) is a new instrument designed to measure student beliefs about physics and about learning physics. This instrument extends previous work by probing additional aspects of student beliefs and by using wording suitable for students in a wide variety of physics courses. The CLASS has been validated using interviews, reliability studies, and extensive statistical analyses of responses from over 5000 students. In addition, a new methodology for determining useful and statistically robust categories of student beliefs has been developed. This paper serves as the foundation for an extensive study of how student beliefs impact and are impacted by their educational experiences. For example, this survey measures the following: that most teaching practices cause substantial drops in student scores; that a student’s likelihood of becoming a physics major correlates with their “Personal Interest” score; and that, for a majority of student populations, women’s scores in some categories, including “Personal Interest” and “Real World Connections,” are significantly different from men’s scores.

  15. a Circleless "2D/3D Total STATION": a Low Cost Instrument for Surveying, Recording Point Clouds, Documentation, Image Acquisition and Visualisation

    Science.gov (United States)

    Scherer, M.

    2013-07-01

    Hardware and software of the universally applicable instrument - referred to as a 2D/3D total station - are described here, as well as its practical use. At its core it consists of a 3D camera - often also called a ToF camera, a pmd camera or a RIM-camera - combined with a common industrial 2D camera. The cameras are rigidly coupled with their optical axes in parallel. A new type of instrument was created mounting this 2D/3D system on a tripod in a specific way. Because of it sharing certain characteristics with a total station and a tacheometer, respectively, the new device was called a 2D/3D total station. It may effectively replace a common total station or a laser scanner in some respects. After a brief overview of the prototype's features this paper then focuses on the methodological characteristics for practical application. Its usability as a universally applicable stand-alone instrument is demonstrated for surveying, recording RGB-coloured point clouds as well as delivering images for documentation and visualisation. Because of its limited range (10m without reflector and 150 m to reflector prisms) and low range accuracy (ca. 2 cm to 3 cm) compared to present-day total stations and laser scanners, the practical usage of the 2D/3D total station is currently limited to acquisition of accidents, forensic purpuses, speleology or facility management, as well as architectural recordings with low requirements regarding accuracy. However, the author is convinced that in the near future advancements in 3D camera technology will allow this type of comparatively low cost instrument to replace the total station as well as the laser scanner in an increasing number of areas.

  16. Psychometric Evaluation of a New Instrument to Evaluate School Nurses' Perceptions on Concussion Care Management.

    Science.gov (United States)

    Schneider, Kathleen H

    2017-10-01

    The rate of concussions in adolescents has risen over the last decade, resulting in cognitive and emotional problems. Neurologists recommend cognitive and physical rest during the recovery period, followed by a transitional return-to-classroom protocol. The purpose of the study was to develop and test an instrument that explores the beliefs and roles of school nurses in concussion care management. The instrument was a cross-sectional descriptive survey based on the theory of planned behavior, using Qualtrics®. The psychometric properties of the instrument were assessed through exploratory factor analysis with orthogonal rotation. The reliability of the instrument was assessed for internal consistency reliability using Cronbach's α. Kaiser-Meyer-Olkin for sample adequacy was .8; Cronbach's α strong (.851).

  17. Quality of persian addiction websites: a survey based on silberg, discern and wqet instruments (2011).

    Science.gov (United States)

    Zahedi, Razieh; Taheri, Behjat; Shahrzadi, Leila; Tazhibi, Mehdi; Ashrafi-rizi, Hasan

    2013-03-01

    Nowadays, World Wide Web is an accessible and widespread resource to attain medical information. So physicians and health institutions try to inform patients about different domains of medicine through Web. Addiction is a noteworthy subject in medicine and a controversial issue among them. However, quality of health information on the internet is doubtful. The objective of this study is to determine the quality of Persian addiction websites to offer recommendation for their improvement. This was survey and an applied study that the study population was all Persian addiction websites. Sample of this study was 28 Persian addiction website which were chosen by searching Persian equivalences of 7 key terms (addiction, addict, addiction center, drug, treatment of addiction, recovery of addiction, addiction withdrawal) into the Google and Yahoo search engines. Finally, the websites were ranked based on the Silberg, DISCERN and WQET instruments. Data were analyzed with Excel software using descriptive statistics. The overall mean of websites in Silberg, DISCERN and WQET instruments were 1.42, 41.89, 64.57. Also the results showed that "Unit of Substance Abuse Treatment" belonging to Mashhad University of Medical Sciences was ranked first based on the Silberg, DISCERN and WQET instruments. 5 (from total of 9), 60 (from total of 80) and 82 (from total of normalized grade 82) were grades for this website for these instruments respectively. It showed that the quality of Persian websites according to Silberg, DISCERN and WQET instruments was "low", "more than half" and "very good" respectively. Not assigning date of entering data, author names, and references of information (authority) were most important missing characteristics of these websites. In addition, lack of interactive opportunities like chat rooms was another problem that leads to dissatisfaction of users.

  18. Pancreatitis Quality of Life Instrument: Development of a new instrument

    Directory of Open Access Journals (Sweden)

    Wahid Wassef

    2014-02-01

    Full Text Available Objectives: The goal of this project was to develop the first disease-specific instrument for the evaluation of quality of life in chronic pancreatitis. Methods: Focus groups and interview sessions were conducted, with chronic pancreatitis patients, to identify items felt to impact quality of life which were subsequently formatted into a paper-and-pencil instrument. This instrument was used to conduct an online survey by an expert panel of pancreatologists to evaluate its content validity. Finally, the modified instrument was presented to patients during precognitive testing interviews to evaluate its clarity and appropriateness. Results: In total, 10 patients were enrolled in the focus groups and interview sessions where they identified 50 items. Once redundant items were removed, the 40 remaining items were made into a paper-and-pencil instrument referred to as the Pancreatitis Quality of Life Instrument. Through the processes of content validation and precognitive testing, the number of items in the instrument was reduced to 24. Conclusions: This marks the development of the first disease-specific instrument to evaluate quality of life in chronic pancreatitis. It includes unique features not found in generic instruments (economic factors, stigma, and spiritual factors. Although this marks a giant step forward, psychometric evaluation is still needed prior to its clinical use.

  19. Academic Research Equipment in the Physical and Computer Sciences and Engineering. An Analysis of Findings from Phase I of the National Science Foundation's National Survey of Academic Research Instruments and Instrumentation Needs.

    Science.gov (United States)

    Burgdorf, Kenneth; White, Kristine

    This report presents information from phase I of a survey designed to develop quantitative indicators of the current national stock, cost/investment, condition, obsolescence, utilization, and need for major research instruments in academic settings. Data for phase I (which focused on the physical and computer sciences and engineering) were…

  20. The Gaia spectrophotometric standard stars survey: II. Instrumental effects of six ground-based observing campaigns

    Science.gov (United States)

    Altavilla, G.; Marinoni, S.; Pancino, E.; Galleti, S.; Ragaini, S.; Bellazzini, M.; Cocozza, G.; Bragaglia, A.; Carrasco, J. M.; Castro, A.; Di Fabrizio, L.; Federici, L.; Figueras, F.; Gebran, M.; Jordi, C.; Masana, E.; Schuster, W.; Valentini, G.; Voss, H.

    2015-08-01

    The Gaia SpectroPhotometric Standard Stars (SPSS) survey started in 2006, was awarded almost 450 observing nights and accumulated almost 100 000 raw data frames with both photometric and spectroscopic observations. Such large observational effort requires careful, homogeneous, and automatic data reduction and quality control procedures. In this paper, we quantitatively evaluate instrumental effects that might have a significant (i.e., ≥ 1 %) impact on the Gaia SPSS flux calibration. The measurements involve six different instruments, monitored over the eight years of observations dedicated to the Gaia flux standards campaigns: DOLORES@TNG in La Palma, EFOSC2@NTT and ROSS@REM in La Silla, CAFOS@2.2 m in Calar Alto, BFOSC@Cassini in Loiano, and LaRuca@1.5 m in San Pedro Mártir. We examine and quantitatively evaluate the following effects: CCD linearity and shutter times, calibration frames stability, lamp flexures, second order contamination, light polarization, and fringing. We present methods to correct for the relevant effects which can be applied to a wide range of observational projects at similar instruments. Based on data obtained with BFOSC@Cassini in Loiano, Italy; EFOSC2@NTT in La Silla, Chile; DOLORES@TNG in La Palma, Spain; CAFOS@2.2 m in Calar Alto, Spain; LaRuca@1.5 m in San Pedro Mártir, Mexico (see acknowledgements for more details).

  1. Psychometric Analysis and Qualitative Review of an Outpatient Radiology-Specific Patient Satisfaction Survey: A Call for Collaboration in Validating a Survey Instrument.

    Science.gov (United States)

    Dibble, Elizabeth H; Baird, Grayson L; Swenson, David W; Healey, Terrance T

    2017-10-01

    The aim of this study was to perform a psychometric analysis of the constructs and reliability of an outpatient radiology-specific patient satisfaction survey and identify factors that drive patient experience so that radiology practices can improve the quality of their diagnostic imaging services. This retrospective study examined responses to eight patient satisfaction questions from a survey originally developed by a nascent marketing team and then administered at five outpatient imaging centers from January 7, 2013, to November 11, 2015. Patients' responses were reviewed to identify factors that affected patient experience, and a psychometric analysis of the survey instrument itself was performed, including exploratory factor analyses and reliability testing. Patient responses were compared among sites, examination types, and questions. Free-text comments were qualitatively categorized and compared by examination type. In total, 6,512 surveys were completed among 137,059 patient encounters. Using exploratory factor analyses of the eight survey questions, three relevant patient experience constructs were derived: (1) front office experience, (2) intake experience, and (3) examination experience. Overall, good scale reliability was observed. Perceived quality of care had the most positive ratings; wait time had the most nonpositive ratings. Of 2,024 free-text comments, 1,859 were positive (most pertaining to staff), and 155 were negative (most pertaining to convenience). MRI patients were most likely to share negative comments, typically regarding the examination experience itself. Psychometric analysis of a patient survey derived three core patient experience constructs: front office experience, intake experience, and examination experience. The survey indicates the need to decrease wait times, streamline the registration process, and improve patient comfort during MRI examinations. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All

  2. An Attitude Scale on Individual Instrument and Individual Instrument Course: Validity-Reliability Research

    Science.gov (United States)

    Kuçukosmanoglu, Hayrettin Onur

    2015-01-01

    The main purpose of this study is to develop a scale to determine students' attitude levels on individual instruments and individual instrument courses in instrument training, which is an important dimension of music education, and to conduct a validity-reliability research of the scale that has been developed. The scale consists of 16 items. The…

  3. A summary of the performance of exposure rate and dose rate instruments contained in instrument evaluation reports NRPB-IE1 to NRPB-IE13

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1979-06-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This report provides a concise summary of measurements of the more important performance characteristics of radiation protection dose rate or exposure rate survey instruments which have been assessed by NRPB as part

  4. Impact of instrument response variations on health physics measurements

    International Nuclear Information System (INIS)

    Armantrout, G.A.

    1984-10-01

    Uncertainties in estimating the potential health impact of a given radiation exposure include instrument measurement error in determining exposure and difficulty in relating this exposure to an effective dose value. Instrument error can be due to design or manufacturing deficiencies, limitations of the sensing element used, and calibration and maintenance of the instrument. This paper evaluates the errors which can be introduced by design deficiencies and limitations of the sensing element for a wide variety of commonly used survey instruments. The results indicate little difference among sensing element choice for general survey work, with variations among specific instrument designs being the major factor. Ion chamber instruments tend to be the best for all around use, while scintillator-based units should not be used where accurate measurements are required. The need to properly calibrate and maintain an instrument appears to be the most important factor in instrument accuracy. 8 references, 6 tables

  5. Patient experience and satisfaction with inpatient service: development of short form survey instrument measuring the core aspect of inpatient experience.

    Directory of Open Access Journals (Sweden)

    Eliza L Y Wong

    Full Text Available Patient experience reflects quality of care from the patients' perspective; therefore, patients' experiences are important data in the evaluation of the quality of health services. The development of an abbreviated, reliable and valid instrument for measuring inpatients' experience would reflect the key aspect of inpatient care from patients' perspective as well as facilitate quality improvement by cultivating patient engagement and allow the trends in patient satisfaction and experience to be measured regularly. The study developed a short-form inpatient instrument and tested its ability to capture a core set of inpatients' experiences. The Hong Kong Inpatient Experience Questionnaire (HKIEQ was established in 2010; it is an adaptation of the General Inpatient Questionnaire of the Care Quality Commission created by the Picker Institute in United Kingdom. This study used a consensus conference and a cross-sectional validation survey to create and validate a short-form of the Hong Kong Inpatient Experience Questionnaire (SF-HKIEQ. The short-form, the SF-HKIEQ, consisted of 18 items derived from the HKIEQ. The 18 items mainly covered relational aspects of care under four dimensions of the patient's journey: hospital staff, patient care and treatment, information on leaving the hospital, and overall impression. The SF-HKIEQ had a high degree of face validity, construct validity and internal reliability. The validated SF-HKIEQ reflects the relevant core aspects of inpatients' experience in a hospital setting. It provides a quick reference tool for quality improvement purposes and a platform that allows both healthcare staff and patients to monitor the quality of hospital care over time.

  6. Dental Management Survey Brazil (DMS-BR): creation and validation of a management instrument

    Science.gov (United States)

    Gonzales, Paola Sampaio; Martins, Ismar Eduardo; Biazevic, Maria Gabriela Haye; Silva, Paulo Roberto da; Michel-Crosato, Edgard

    2017-04-10

    Questionnaires for the assessment of knowledge and self-perception can be useful to diagnose what a dentist knows about management and administration. The aim of the present study was to create and validate the Dental Management Survey Brazil (DMS-BR) scale, based on meetings with experts in the field. After having elaborated the first version, 10 audits were performed in dental offices in order to produce the final version, which included nine dimensions: location, patient, finance, marketing, competition, quality, staff, career, and productivity. The accuracy of the instrument was measured by intrarater and interrater reliability. In the validation phase, 247 Brazilian dentists answered a web-based questionnaire. The data were processed using Stata 13.0 and the significance level was set at 95%. The instrument had intrarater and interrater reliability (ICC-0.93 and 0.94). The overall average of respondents for the DMS-BR scale was 3.77 (SD = 0.45). Skewness and kurtosis were below absolute values 3 and 7, respectively. Internal validity measured by Cronbach's alpha was 0.925 and the correlation of each dimension with the final result of the DMS-BR ranged between 0.606 and 0.810. Correlation with the job satisfaction scale was 0.661. The SEM data ranged between 0.80 and 0.56. The questionnaire presented satisfactory indicators of dentists' self-perception about management and administration activities.

  7. Instrument Psychometrics: Parental Satisfaction and Quality Indicators of Perinatal Palliative Care.

    Science.gov (United States)

    Wool, Charlotte

    2015-10-01

    Despite a life-limiting fetal diagnosis, prenatal attachment often occurs in varying degrees resulting in role identification by an individual as a parent. Parents recognize quality care and report their satisfaction when interfacing with health care providers. The aim was to test an instrument measuring parental satisfaction and quality indicators with parents electing to continue a pregnancy after learning of a life-limiting fetal diagnosis. A cross sectional survey design gathered data using a computer-mediated platform. Subjects were parents (n=405) who opted to continue a pregnancy affected by a life-limiting diagnosis. Factor analysis using principal component analysis with Varimax rotation was used to validate the instrument, evaluate components, and summarize the explained variance achieved among quality indicator items. The Prenatal Scale was reduced to 37 items with a three-component solution explaining 66.19% of the variance and internal consistency reliability of 0.98. The Intrapartum Scale included 37 items with a four-component solution explaining 66.93% of the variance and a Cronbach α of 0.977. The Postnatal Scale was reduced to 44 items with a six-component solution explaining 67.48% of the variance. Internal consistency reliability was 0.975. The Parental Satisfaction and Quality Indicators of Perinatal Palliative Care Instrument is a valid and reliable measure for parent-reported quality care and satisfaction. Use of this instrument will enable clinicians and researchers to measure quality indicators and parental satisfaction. The instrument is useful for assessing, analyzing, and reporting data on quality for care delivered during the prenatal, intrapartum, and postnatal periods.

  8. Implementation of graduate employability skills SJT instrument in Universiti Utara Malaysia

    Science.gov (United States)

    Zakaria, Mohd Hafiz; Yatim, Bidin; Ismail, Suzilah

    2014-12-01

    Assessing graduate employability skills before they enter the job market is very important because if they are lacking certain skills, improvement can be made through the process of training. In this study, a valid and reliable new instrument for measuring graduate employability skills using Situational Judgement Test (SJT) approach was implemented. The instrument consisted of 12 items representing five employability skills namely communication skill, professional ethics & morality, entrepreneurial skill, critical thinking in problem solving and personal quality. The purpose was to obtain a norm score for each of these skills. A survey was conducted using the SJT instrument on 1012 Universiti Utara Malaysia (UUM) local undergraduate final year students. The norm score was generated by employing BCA bootstrap technique. Scores guideline was created based on three levels (low, moderate and high). The outcomes indicated that the students possessed moderate level of communicationskill, entrepreneurial skill, critical thinking in problem solving and personal quality but has high professional ethics & morality.

  9. Peer Learning in Instrumental Practicing.

    Science.gov (United States)

    Nielsen, Siw G; Johansen, Guro G; Jørgensen, Harald

    2018-01-01

    In higher music education (HME), the notion of "private teaching, private learning" has a long tradition, where the learning part rests on the student's individual practicing between instrumental lessons. However, recent research suggests that collaborative learning among peers is beneficial in several aspects, such as sense of belonging, motivation and self-efficacy. This is consistent with the concept of vicarious learning. In this study, we conducted a survey among bachelor music students in church music, performance or music education programs enrolled in a music academy ( N = 96), where parts of the questionnaire addressed peer learning and peer's influence on the students's instrumental practicing, and the degree of satisfaction with their practicing. These issues were seen in relation to gender, musical genre and study program. Overall, the students reported engaging in peer learning related to their instrumental practicing, to various degrees. This involved discussing practicing matters with peers, and practicing together with peers. However, student's reports of their views on peer learning, show that they perceive it more beneficial than the amount of time reported doing it would indicate. No significant gender differences were found, but students within improvised music/jazz engaged the most in peer learning, and church music students the least. Neither the degree of engaging in peer learning nor reported influence from peers correlated significantly with the degree of satisfaction. We discuss whether a general dissatisfaction is caused by being in a competitive learning environment combined with a privatized culture for learning. Finally, we suggest that collaborative forums for instrumental practicing within HME institutions can function as constructive and supportive arenas to enhance students learning and inner motivation.

  10. Peer Learning in Instrumental Practicing

    Science.gov (United States)

    Nielsen, Siw G.; Johansen, Guro G.; Jørgensen, Harald

    2018-01-01

    In higher music education (HME), the notion of “private teaching, private learning” has a long tradition, where the learning part rests on the student's individual practicing between instrumental lessons. However, recent research suggests that collaborative learning among peers is beneficial in several aspects, such as sense of belonging, motivation and self-efficacy. This is consistent with the concept of vicarious learning. In this study, we conducted a survey among bachelor music students in church music, performance or music education programs enrolled in a music academy (N = 96), where parts of the questionnaire addressed peer learning and peer's influence on the students's instrumental practicing, and the degree of satisfaction with their practicing. These issues were seen in relation to gender, musical genre and study program. Overall, the students reported engaging in peer learning related to their instrumental practicing, to various degrees. This involved discussing practicing matters with peers, and practicing together with peers. However, student's reports of their views on peer learning, show that they perceive it more beneficial than the amount of time reported doing it would indicate. No significant gender differences were found, but students within improvised music/jazz engaged the most in peer learning, and church music students the least. Neither the degree of engaging in peer learning nor reported influence from peers correlated significantly with the degree of satisfaction. We discuss whether a general dissatisfaction is caused by being in a competitive learning environment combined with a privatized culture for learning. Finally, we suggest that collaborative forums for instrumental practicing within HME institutions can function as constructive and supportive arenas to enhance students learning and inner motivation. PMID:29599738

  11. Peer Learning in Instrumental Practicing

    Directory of Open Access Journals (Sweden)

    Siw G. Nielsen

    2018-03-01

    Full Text Available In higher music education (HME, the notion of “private teaching, private learning” has a long tradition, where the learning part rests on the student's individual practicing between instrumental lessons. However, recent research suggests that collaborative learning among peers is beneficial in several aspects, such as sense of belonging, motivation and self-efficacy. This is consistent with the concept of vicarious learning. In this study, we conducted a survey among bachelor music students in church music, performance or music education programs enrolled in a music academy (N = 96, where parts of the questionnaire addressed peer learning and peer's influence on the students's instrumental practicing, and the degree of satisfaction with their practicing. These issues were seen in relation to gender, musical genre and study program. Overall, the students reported engaging in peer learning related to their instrumental practicing, to various degrees. This involved discussing practicing matters with peers, and practicing together with peers. However, student's reports of their views on peer learning, show that they perceive it more beneficial than the amount of time reported doing it would indicate. No significant gender differences were found, but students within improvised music/jazz engaged the most in peer learning, and church music students the least. Neither the degree of engaging in peer learning nor reported influence from peers correlated significantly with the degree of satisfaction. We discuss whether a general dissatisfaction is caused by being in a competitive learning environment combined with a privatized culture for learning. Finally, we suggest that collaborative forums for instrumental practicing within HME institutions can function as constructive and supportive arenas to enhance students learning and inner motivation.

  12. Development of aerial gamma radiation survey system, 1

    International Nuclear Information System (INIS)

    Tsutsumi, Masahiro; Saito, Komei; Sakamoto, Ryuichi; Nagaoka, Toshi; Moriuchi, Shigeru

    1986-05-01

    JAERI has started to develop an aerial gamma radiation survey system by a helicopter in 1980. The development of measuring instruments, the experiments in the field of natural and artificial radiation sources, and the imaginary emergency survey at a real site, were executed. This report describes mainly about the hardware and software of this system. The system consists of gamma-ray measuring instruments with NaI(Tl) scintillation detectors, microwave positioning instruments, and a data processing system for postflight data. A foreign-made geological survey system is improved on for radiation measurements. For covering the wide radiation range, detectors of various shapes and sizes are prepared, from a large volume detector, DET-1024 - four 4'' x 4'' x 16'' crystals assembly - to a 2'' diameter x 2'' NaI(Tl) crystal. Radiation and position data are recorded on a magnetic tape, and computer-processed afterwards. Moreover, scene below flight courses and internal communication are recorded on video tape with the information of clock and position superimposed. In consequence of field experiments carried out five times, basic radiation data for evaluating airborne acquired data are accumulated, and flight survey procedures are established. As more practical use, a system has been produced more compactly and functionally. Exposure rates (> 1 mR/h), energy distribution spectra, and energy window counts are obtained for radiation data. Using the Spectrum-Dose Conversion Method, the accurate exposure rates are directly calculated from pulse height spectra. Numerical tables of G(E) function converting pulse height spectra into exposures are shown in this report. As regards the analysis of survey data, process codes have been completed with either large-computer or mini-computer. (author)

  13. Gender, Sexual Orientation, and Rape Myth Acceptance: Preliminary Findings From a Sample of Primarily LGBQ-Identified Survey Respondents.

    Science.gov (United States)

    Schulze, Corina; Koon-Magnin, Sarah

    2017-02-01

    This study is among the first to examine the relationship between sexual orientation and rape myth adherence using a nationwide survey of primarily lesbian, gay, bisexual, and queer (LGBQ) respondents (n = 184). The more established Illinois Rape Myth Acceptance Scale and a modified Male Rape Survey serve as the primary instruments to test both rape myth adherence and instrument-appropriateness. Results suggest that respondents were most likely to support myths that discredit sexual assault allegations or excuse rape as a biological imperative and least likely to support myths related to physical resistance. Consistent with previous work, men exhibited higher levels of rape myth adherence than women. Regarding sexual orientation, respondents who identified as queer consistently exhibited lower levels of rape myth adherence than respondents who identified as gay.

  14. Nuclear instrument maintenance - problems, solutions, and obstacles

    International Nuclear Information System (INIS)

    Vuister, P.H.

    1983-01-01

    In 200 laboratories of South-East Asia, Latin America and Africa a survey was made of the state of instrumentation for nuclear medicine. The principal cause of failures and defects was inadequate quality control and preventive maintenance. On the basis of the survey coordinated research programs were compiled for the maintenance of nuclear instruments. The four principal points of the programs are: to safeguard quality and stable electric power supplies for the instruments, to safeguard permanent temperature and humidity in the environment in which the equipment is operated, effective maintenance, and training of personnel. In the years 1981 and 1982, 14 local training courses were run in which emphasis was put on practicals and tests in mechanics and electronics

  15. Developing a survey instrument to assess the readiness of primary care data, genetic and disease registries to conduct linked research: TRANSFoRm International Research Readiness (TIRRE survey instrument

    Directory of Open Access Journals (Sweden)

    Emily Leppenwell

    2013-05-01

    Full Text Available Background Clinical data are collected for routine care in family practice; there are also a growing number of genetic and cancer registry data repositories. The Translational Research and Patient Safety in Europe (TRANSFoRm project seeks to facilitate research using linked data from more than one source. We performed a requirements analysis which identified a wide range of data and business process requirements that need to be met before linking primary care and either genetic or disease registry data.Objectives To develop a survey to assess the readiness of data repositories to participate in linked research – the Transform International Research Readiness (TIRRE survey.Method We develop the questionnaire based on our requirement analysis; with questions at micro-, meso- and macro levels of granularity, study-specific questions about diabetes and gastro-oesophageal reflux disease (GORD, and research track record. The scope of the data required was extensive. We piloted this instrument, conducting ten preliminary telephone interviews to evaluate the response to the questionnaire.Results Using feedback gained from these interviews we revised the questionnaire; clarifying questions that were difficult to answer and utilising skip logic to create different series of questions for the various types of data repository. We simplified the questionnaire replacing free-text responses with yes/no or picking list options, wherever possible. We placed the final questionnaire online and encouraged its use (www.clininf.eu/jointirre/info.html.Conclusion Limited field testing suggests that TIRRE is capable of collecting comprehensive and relevant data about the suitability and readiness of data repositories to participate in linked data research.

  16. On a Modular Approach to the Design of Integrated Social Surveys

    Directory of Open Access Journals (Sweden)

    Ioannidis Evangelos

    2016-06-01

    Full Text Available This article considers a modular approach to the design of integrated social surveys. The approach consists of grouping variables into ‘modules’, each of which is then allocated to one or more ‘instruments’. Each instrument is then administered to a random sample of population units, and each sample unit responds to all modules of the instrument. This approach offers a way of designing a system of integrated social surveys that balances the need to limit the cost and the need to obtain sufficient information. The allocation of the modules to instruments draws on the methodology of split questionnaire designs. The composition of the instruments, that is, how the modules are allocated to instruments, and the corresponding sample sizes are obtained as a solution to an optimisation problem. This optimisation involves minimisation of respondent burden and data collection cost, while respecting certain design constraints usually encountered in practice. These constraints may include, for example, the level of precision required and dependencies between the variables. We propose using a random search algorithm to find approximate optimal solutions to this problem. The algorithm is proved to fulfil conditions that ensure convergence to the global optimum and can also produce an efficient design for a split questionnaire.

  17. Portable radiation instrumentation traceability of standards and measurements

    International Nuclear Information System (INIS)

    Wiserman, A.; Walke, M.

    1995-01-01

    Portable radiation measuring instruments are used to estimate and control doses for workers. Calibration of these instruments must be sufficiently accurate to ensure that administrative and legal dose limits are not likely to be exceeded due to measurement uncertainties. An instrument calibration and management program is established which permits measurements made with an instrument to be traced to a national standard. This paper describes the establishment and maintenance of calibration standards for gamma survey instruments and an instrument management program which achieves traceability of measurement for uniquely identified field instruments. (author)

  18. Instrumental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-15

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  19. Instrumental analysis

    International Nuclear Information System (INIS)

    Kim, Seung Jae; Seo, Seong Gyu

    1995-03-01

    This textbook deals with instrumental analysis, which consists of nine chapters. It has Introduction of analysis chemistry, the process of analysis and types and form of the analysis, Electrochemistry on basic theory, potentiometry and conductometry, electromagnetic radiant rays and optical components on introduction and application, Ultraviolet rays and Visible spectrophotometry, Atomic absorption spectrophotometry on introduction, flame emission spectrometry and plasma emission spectrometry. The others like infrared spectrophotometry, X-rays spectrophotometry and mass spectrometry, chromatography and the other instrumental analysis like radiochemistry.

  20. The Nursing Performance Instrument: Exploratory and Confirmatory Factor Analyses in Registered Nurses.

    Science.gov (United States)

    Sagherian, Knar; Steege, Linsey M; Geiger-Brown, Jeanne; Harrington, Donna

    2018-04-01

    The optimal performance of nurses in healthcare settings plays a critical role in care quality and patient safety. Despite this importance, few measures are provided in the literature that evaluate nursing performance as an independent construct from competencies. The nine-item Nursing Performance Instrument (NPI) was developed to fill this gap. The aim of this study was to examine and confirm the underlying factor structure of the NPI in registered nurses. The design was cross-sectional, using secondary data collected between February 2008 and April 2009 for the "Fatigue in Nursing Survey" (N = 797). The sample was predominantly dayshift female nurses working in acute care settings. Using Mplus software, exploratory and confirmatory factor analyses were applied to the NPI data, which were divided into two equal subsamples. Multiple fit indices were used to evaluate the fit of the alternative models. The three-factor model was determined to fit the data adequately. The factors that were labeled as "physical/mental decrements," "consistent practice," and "behavioral change" were moderately to strongly intercorrelated, indicating good convergent validity. The reliability coefficients for the subscales were acceptable. The NPI consists of three latent constructs. This instrument has the potentialto be used as a self-monitoring instrument that addressesnurses' perceptions of performance while providing patient care.

  1. Development and psychometric evaluation of an information literacy self-efficacy survey and an information literacy knowledge test.

    Science.gov (United States)

    Tepe, Rodger; Tepe, Chabha

    2015-03-01

    To develop and psychometrically evaluate an information literacy (IL) self-efficacy survey and an IL knowledge test. In this test-retest reliability study, a 25-item IL self-efficacy survey and a 50-item IL knowledge test were developed and administered to a convenience sample of 53 chiropractic students. Item analyses were performed on all questions. The IL self-efficacy survey demonstrated good reliability (test-retest correlation = 0.81) and good/very good internal consistency (mean κ = .56 and Cronbach's α = .92). A total of 25 questions with the best item analysis characteristics were chosen from the 50-item IL knowledge test, resulting in a 25-item IL knowledge test that demonstrated good reliability (test-retest correlation = 0.87), very good internal consistency (mean κ = .69, KR20 = 0.85), and good item discrimination (mean point-biserial = 0.48). This study resulted in the development of three instruments: a 25-item IL self-efficacy survey, a 50-item IL knowledge test, and a 25-item IL knowledge test. The information literacy self-efficacy survey and the 25-item version of the information literacy knowledge test have shown preliminary evidence of adequate reliability and validity to justify continuing study with these instruments.

  2. OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. V. TOWARD AN EMPIRICAL METAL-POOR MASS–LUMINOSITY RELATION

    International Nuclear Information System (INIS)

    Horch, Elliott P.; Van Altena, William F.; Demarque, Pierre; Howell, Steve B.; Everett, Mark E.; Ciardi, David R.; Teske, Johanna K.; Henry, Todd J.; Winters, Jennifer G.

    2015-01-01

    In an effort to better understand the details of the stellar structure and evolution of metal-poor stars, the Gemini North telescope was used on two occasions to take speckle imaging data of a sample of known spectroscopic binary stars and other nearby stars in order to search for and resolve close companions. The observations were obtained using the Differential Speckle Survey Instrument, which takes data in two filters simultaneously. The results presented here are of 90 observations of 23 systems in which one or more companions was detected, and six stars where no companion was detected to the limit of the camera capabilities at Gemini. In the case of the binary and multiple stars, these results are then further analyzed to make first orbit determinations in five cases, and orbit refinements in four other cases. The mass information is derived, and since the systems span a range in metallicity, a study is presented that compares our results with the expected trend in total mass as derived from the most recent Yale isochrones as a function of metal abundance. These data suggest that metal-poor main-sequence stars are less massive at a given color than their solar-metallicity analogues in a manner consistent with that predicted from the theory

  3. The Iranian version of 12-item Short Form Health Survey (SF-12: factor structure, internal consistency and construct validity

    Directory of Open Access Journals (Sweden)

    Mousavi Sayed

    2009-09-01

    Full Text Available Abstract Background The 12-item Short Form Health Survey (SF-12 as a shorter alternative of the SF-36 is largely used in health outcomes surveys. The aim of this study was to validate the SF-12 in Iran. Methods A random sample of the general population aged 15 years and over living in Tehran, Iran completed the SF-12. Reliability was estimated using internal consistency and validity was assessed using known groups comparison and convergent validity. In addition, the factor structure of the questionnaire was extracted by performing both exploratory factor analysis (EFA and confirmatory factor analysis (CFA. Results: In all, 5587 individuals were studied (2721 male and 2866 female. The mean age and formal education of the respondents were 35.1 (SD = 15.4 and 10.2 (SD = 4.4 years respectively. The results showed satisfactory internal consistency for both summary measures, that are the Physical Component Summary (PCS and the Mental Component Summary (MCS; Cronbach's α for PCS-12 and MCS-12 was 0.73 and 0.72, respectively. Known-groups comparison showed that the SF-12 discriminated well between men and women and those who differed in age and educational status (P Conclusion In general the findings suggest that the SF-12 is a reliable and valid measure of health related quality of life among Iranian population. However, further studies are needed to establish stronger psychometric properties for this alternative form of the SF-36 Health Survey in Iran.

  4. Assessment of the Measurement Properties of the NHCAHPS Family Survey: A Rasch Scaling Approach

    Science.gov (United States)

    O'Connor, Matthew S.

    2013-01-01

    The introduction of the Consumer Assessment of Healthcare Providers and Systems (CAHPS), a family of survey instruments designed to capture and report people's experiences obtaining health care could soon add satisfaction as a consistent dimension of quality that skilled nursing facilities (SNFs) are required to assess and report. The SNF setting…

  5. An instrument to measure passenger satisfaction of a public transport system

    Directory of Open Access Journals (Sweden)

    Viviane Leite Dias de Mattos

    2017-03-01

    Full Text Available This study proposes an instrument, based on fuzzy logic, to measure the satisfaction with the public transport. It is based on previous studies, expert opinion and results of two surveys conducted among the data samples of the studied population: a university community. Qualitative techniques (questionaries and interviews were used for validating content, while the construct validation uses quantitative techniques (Factor Analysis and Reliability Analysis. An experiment is also performed to define some properties of fuzzy controllers: membership function and method of defuzzification. The final instrument consists of twenty items in four dimensions, namely: service, stops/terminals, vehicle and safety. It is considered valid and reliable by the present study. It can be used as a tool to understand the satisfaction of the passengers of public transport system investigated. It can also provide subsidies for managers to improve their work quality.

  6. INSTRUMENTATION FOR ENVIRONMENTAL MONITORING--Radiation--Vol3Pt1

    Energy Technology Data Exchange (ETDEWEB)

    Authors, Various

    1972-01-02

    A comprehensive survey of instrumentation for environmental monitoring is being carried out by the Lawrence Berkeley Laboratory originally under a grant from the National Science Foundation and now by the Office of Health and Environmental Research of the Department of Energy. Instruments being investigated are those useful for measurements in Air Quality, Water Quality, Radiation, and Biomedicine related to environmental research and monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to this work. The results of the survey are given as (a) descriptions of the physical and operating characteristics of available instruments, (b) critical comparisons among instrumentation methods, and (c) recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored: their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls.

  7. Smart instrumentation development at Los Alamos

    International Nuclear Information System (INIS)

    Erkkila, B.

    1984-01-01

    For several years Los Alamos has incorporated microprocessors into instruments to expand the capability of portable survey type equipment. Beginning with portable pulse height analyzers, the developments have expanded to small dedicated instruments which handle the measurement and interpretation of various radiation fields. So far, instruments to measure gamma rays, neutrons, and beta particles have been produced. The computer capability built into these instruments provides significant computational power into the instruments. Capability unheard of a few years ago in small portable instruments is routine today. Large computer-based laboratory measurement systems which required much space and electrical power can now be incorporated in a portable hand-held instrument. The microprocessor developments at Los Alamos are now restricted to radiation monitoring equipment but can be expanded to chemical and biological applications as well. Applications for radiation monitoring equipment and others are discussed

  8. Update of Earthquake Strong-Motion Instrumentation at Lawrence Livermore National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Murray, Robert C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-09-01

    Following the January 1980 earthquake that was felt at Lawrence Livermore National Laboratory (LLNL), a network of strong-motion accelerographs was installed at LLNL. Prior to the 1980 earthquake, there were no accelerographs installed. The ground motion from the 1980 earthquake was estimated from USGS instruments around the Laboratory to be between 0.2 – 0.3 g horizontal peak ground acceleration. These instruments were located at the Veterans Hospital, 5 miles southwest of LLNL, and in San Ramon, about 12 miles west of LLNL. In 2011, the Department of Energy (DOE) requested to know the status of our seismic instruments. We conducted a survey of our instrumentation systems and responded to DOE in a letter. During this survey, it was found that the recorders in Buildings 111 and 332 were not operational. The instruments on Nova had been removed, and only three of the 10 NIF instruments installed in 2005 were operational (two were damaged and five had been removed from operation at the request of the program). After the survey, it was clear that the site seismic instrumentation had degraded substantially and would benefit from an overhaul and more attention to ongoing maintenance. LLNL management decided to update the LLNL seismic instrumentation system. The updated system is documented in this report.

  9. Practical guidelines for developing a smartphone-based survey instrument

    DEFF Research Database (Denmark)

    Ohme, Jakob; de Vreese, Claes Holger; Albæk, Erik

    The increasing relevance of mobile surveys makes it important to gather empirical evidence on designs of such surveys. This research note presents the results of a test study conducted to identify the best set-up for a smartphone-based survey. We base our analysis on a random sample of Danish...

  10. Interfacing to accelerator instrumentation

    International Nuclear Information System (INIS)

    Shea, T.J.

    1995-01-01

    As the sensory system for an accelerator, the beam instrumentation provides a tremendous amount of diagnostic information. Access to this information can vary from periodic spot checks by operators to high bandwidth data acquisition during studies. In this paper, example applications will illustrate the requirements on interfaces between the control system and the instrumentation hardware. A survey of the major accelerator facilities will identify the most popular interface standards. The impact of developments such as isochronous protocols and embedded digital signal processing will also be discussed

  11. Evaluating the Relational Coordination instrument

    DEFF Research Database (Denmark)

    Edwards, Kasper; Lundstrøm, Sanne Lykke

    2014-01-01

    consistency, interrater agreement and reliability, structural validity, content validity. However as relational coordination is being used as a diagnostics tool it is important to examine further if the instrument can measure changes. Indeed we need to know how precise and sensitive the instrument is when....... We distinguish between statistical and clinical significance. Statistical significance is calculated using T-test. Clinical significance is the minimal amount of change in relational coordination score that is not considered noise. Sensitivity of the instrument i.e. the ability of the instrument...

  12. Reliability of AOFAS diabetic foot questionnaire in Charcot arthropathy: stability, internal consistency, and measurable difference.

    Science.gov (United States)

    Dhawan, Vibhu; Spratt, Kevin F; Pinzur, Michael S; Baumhauer, Judith; Rudicel, Sally; Saltzman, Charles L

    2005-09-01

    The development of Charcot changes is known to be associated with a high rate of recurrent ulceration and amputation. Unfortunately, the effect of Charcot arthropathy on quality of life in diabetic patients has not been systematically studied because of a lack of a disease-specific instrument. The purpose of this study was to develop and test an instrument to evaluate the health-related quality of life of diabetic foot disease. Subjects diagnosed with Charcot arthropathy completed a patient self-administered questionnaire, and clinicians completed an accompanying observational survey. The patient self-administered questionnaire was organized into five general sections: demographics, general health, diabetes-related symptoms, comorbidities, and satisfaction. The scales measured the effect in six health domains: 1) general health, 2) care, 3) worry, 4) sleep, 5) emotion, and 6) physicality. The psychometric properties of the scales were evaluated and the summary scores for the Short-Form Health Survey (SF-36) were compared to published norms for other major medical illnesses. Of the 89 enrolled patients, 57 who completed the questionnaire on enrollment returned a second completed form at 3-month followup. Over the 3-month followup period most of the patients showed an improvement in the Eichenholtz staging. The internal consistency of most was moderate to high and, in general, the scale scores were stable over 3 months. However, several of the scales suffered from low-ceiling or high-floor effects. Patients with Charcot arthropathy had a much lower physical component score on enrollment than the reported norms for other disease conditions, including diabetes. Quality of life represents an important set of outcomes when evaluating the effectiveness of treatment for patients with Charcot arthropathy. This study represents an initial attempt to develop a standardized survey for use with this patient population. Further studies need to be done with larger groups of

  13. Two-Sample Two-Stage Least Squares (TSTSLS estimates of earnings mobility: how consistent are they?

    Directory of Open Access Journals (Sweden)

    John Jerrim

    2016-08-01

    Full Text Available Academics and policymakers have shown great interest in cross-national comparisons of intergenerational earnings mobility. However, producing consistent and comparable estimates of earnings mobility is not a trivial task. In most countries researchers are unable to observe earnings information for two generations. They are thus forced to rely upon imputed data from different surveys instead. This paper builds upon previous work by considering the consistency of the intergenerational correlation (ρ as well as the elasticity (β, how this changes when using a range of different instrumental (imputer variables, and highlighting an important but infrequently discussed measurement issue. Our key finding is that, while TSTSLS estimates of β and ρ are both likely to be inconsistent, the magnitude of this problem is much greater for the former than it is for the latter. We conclude by offering advice on estimating earnings mobility using this methodology.

  14. Aspects of progress in neutron instrumentation

    International Nuclear Information System (INIS)

    Carlile, C.J.

    1999-01-01

    The capability of neutron instrumentation in coming years will depend upon many factors, the main ones being the neutron source the instrument is sited on, the quality of the instrument itself, the quality of the support provided and the protocol for instrument operation. All of these factors must be optimised and improved upon to ensure consistently high quality scientific exploitation of an instrument. Examples of progress in each of these fields are given and a subjective view of possible future trends are hazarded. (author)

  15. PEP Laser Surveying System

    International Nuclear Information System (INIS)

    Lauritzen, T.; Sah, R.C.

    1979-03-01

    A Laser Surveying System has been developed to survey the beam elements of the PEP storage ring. This system provides automatic data acquisition and analysis in order to increase survey speed and to minimize operator error. Two special instruments, the Automatic Readout Micrometer and the Small Automatic Micrometer, have been built for measuring the locations of fiducial points on beam elements with respect to the light beam from a laser. These instruments automatically encode offset distances and read them into the memory of an on-line computer. Distances along the beam line are automatically encoded with a third instrument, the Automatic Readout Tape Unit. When measurements of several beam elements have been taken, the on-line computer analyzes the measured data, compared them with desired parameters, and calculates the required adjustments to beam element support stands

  16. Preventing intentional food contamination: a survey to assess restaurant preparedness.

    Science.gov (United States)

    Xirasagar, Sudha; Kanwat, C P; Qu, Haiyan; Smith, Lillian U; Patterson, Nathaniel J; Shewchuk, Richard M

    2010-01-01

    In the age of preparedness, public health agencies are concerned with intentional acts of food contamination in restaurants, in addition to food safety. Food safety consists of applying standard norms of practice and infrastructure, which, if violated, cause food-borne illness. In contrast, food defense requires an institutionalized mindset of informed alertness to unusual variations from the norms, combined with preemptive practices best suited to each restaurant. Therefore, while food safety lends itself to regulation to ensure standard practices, food defense is best served by advisory guidelines for autonomous application, preserving the restaurant industry's core values of hospitality and customer service. To address this challenge, public health agencies need survey tools that can yield action-relevant data on the knowledge and practice gaps in food defense preparedness and on educational messages and support services to be developed for maximum impact potential. This article presents a mail survey instrument, developed using qualitative research to ensure content and face validity. Instrument development involved drafting the survey on the basis of expert consultations, validating its content by using focus groups (representing all restaurant categories and geographic regions), and ensuring face validity through cognitive interviews. The resulting survey remains sensitive to the hospitality industry while encompassing all vulnerable points.

  17. Assessment of Customer Service in Academic Health Care Libraries (ACSAHL): an instrument for measuring customer service.

    Science.gov (United States)

    Crossno, J E; Berkins, B; Gotcher, N; Hill, J L; McConoughey, M; Walters, M

    2001-04-01

    In a pilot study, the library had good results using SERVQUAL, a respected and often-used instrument for measuring customer satisfaction. The SERVQUAL instrument itself, however, received some serious and well-founded criticism from the respondents to our survey. The purpose of this study was to test the comparability of the results of SERVQUAL with a revised and shortened instrument modeled on SERVQUAL. The revised instrument, the Assessment of Customer Service in Academic Health Care Libraries (ACSAHL), was designed to better assess customer service in academic health care libraries. Surveys were sent to clients who had used the document delivery services at three academic medical libraries in Texas over the previous twelve to eighteen months. ACSAHL surveys were sent exclusively to clients at University of Texas (UT) Southwestern, while the client pools at the two other institutions were randomly divided and provided either SERVQUAL or ACSAHL surveys. Results indicated that more respondents preferred the shorter ACSAHL instrument to the longer and more complex SERVQUAL instrument. Also, comparing the scores from both surveys indicated that ACSAHL elicited comparable results. ACSAHL appears to measure the same type of data in similar settings, but additional testing is recommended both to confirm the survey's results through data replication and to investigate whether the instrument applies to different service areas.

  18. OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. II. HIPPARCOS STARS OBSERVED IN 2010 JANUARY AND JUNE

    International Nuclear Information System (INIS)

    Horch, Elliott P.; Gomez, Shamilia C.; Anderson, Lisa M.; Sherry, William H.; Howell, Steve B.; Ciardi, David R.; Van Altena, William F.

    2011-01-01

    The results of 497 speckle observations of Hipparcos stars and selected other targets are presented. Of these, 367 were resolved into components and 130 were unresolved. The data were obtained using the Differential Speckle Survey Instrument at the WIYN 3.5 m Telescope. (The WIYN Observatory is a joint facility of the University of Wisconsin-Madison, Indiana University, Yale University, and the National Optical Astronomy Observatories.) Since the first paper in this series, the instrument has been upgraded so that it now uses two electron-multiplying CCD cameras. The measurement precision obtained when comparing to ephemeris positions of binaries with very well known orbits is approximately 1-2 mas in separation and better than 0. 0 6 in position angle. Differential photometry is found to be in very good agreement with Hipparcos measures in cases where the comparison is most relevant. We derive preliminary orbits for two systems.

  19. Instrumental analysis, second edition

    International Nuclear Information System (INIS)

    Christian, G.D.; O'Reilly, J.E.

    1988-01-01

    The second edition of Instrumental Analysis is a survey of the major instrument-based methods of chemical analysis. It appears to be aimed at undergraduates but would be equally useful in a graduate course. The volume explores all of the classical quantitative methods and contains sections on techniques that usually are not included in a semester course in instrumentation (such as electron spectroscopy and the kinetic methods). Adequate coverage of all of the methods contained in this book would require several semesters of focused study. The 25 chapters were written by different authors, yet the style throughout the book is more uniform than in the earlier edition. With the exception of a two-chapter course in analog and digital circuits, the book purports to de-emphasize instrumentation, focusing more on the theory behind the methods and the application of the methods to analytical problems. However, a detailed analysis of the instruments used in each method is by no means absent. The book has the favor of a user's guide to analysis

  20. GRIP LIGHTNING INSTRUMENT PACKAGE (LIP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Lightning Instrument Package (LIP) dataset was collected by the Lightning Instrument Package (LIP), which consists of 6 rotating vane type electric field...

  1. The one square meter hard X-ray (15-200 KeV) sky survey

    International Nuclear Information System (INIS)

    Ubertini, P.; Bazzano, A.; La Padula, C.D.; Polcaro, V.F.

    1981-01-01

    A long term program was started at I.A.S. since 1979 to perform a survey of the hard X-ray sky using multiwire high pressure Xenon filled Spectroscopic Proportional Counters (SPC). The first payload consisting of two very large area SPC (2,700 cm 2 each) was flown during summer 1980 from the Milo Base (Sicily, Italy). The instrument duplicated to reach 10,800 cm 2 geometric area is expected to fly from northern (1981), southern (1982) and equatorial (1983) bases to perform a deep sky survey

  2. Atomic absorption instrument functional description

    International Nuclear Information System (INIS)

    Bystroff, R.I.; Boyle, W.G. Jr.; Barton, G.W. Jr.

    1976-01-01

    This report describes a proposed system for automating atomic absorption analysis. The system consists of two atomic absorption instruments and an automatic sampler that can be attached to either instrument. A computer program controls the sampling and gathers data. The program then uses the data to perform bookkeeping, data processing, and report writing

  3. An inquiry into chiropractors' intention to treat adolescent idiopathic scoliosis: a telephone survey.

    Science.gov (United States)

    Feise, R J

    2001-01-01

    The primary aim of this study was to (1) determine the clinical management approach of practicing chiropractors with regard to patients with adolescent idiopathic scoliosis and (2) measure the response rate of a telephone survey. A survey instrument was developed and pretested, and a case-specific clinical vignette was generated for a hypothetical typical 12-year-old girl with adolescent idiopathic scoliosis. The instrument addressed 3 domains: the specific management of idiopathic scoliosis, elements guiding the general selection of treatment recommendations, and demographics of respondents. The sample frame consisted of 62,000 US chiropractors, of whom 165 were randomly selected for the survey sample. Interviews were conducted by telephone through use of the tested survey instrument. The response rate was 69% (114/165). Of the 51 nonrespondents, 15 did not have a listed business telephone number and 24 were not in active practice. The response rate of those who met the inclusion criteria (practicing chiropractor with a listed telephone number) was 90% (114/126). The gender, chiropractic college, and years in practice of respondents in this survey were similar to those of respondents in 3 other national surveys. In general, the respondents would provide 6 months of "intensive" chiropractic therapy, then follow the patient for 4 years (near skeletal maturity). Eighty-two percent of respondents named diversified technique as their primary adjustive treatment, 87% would use exercise, and 30% would use electric muscle stimulation as an adjunct to manual therapy. Most surveyed chiropractors would use similar methods (frequency and length of treatment, manipulation technique, and exercise) in the treatment of patients with adolescent idiopathic scoliosis. A high response rate to a national survey can be achieved through use of telephone contact.

  4. GRIP LIGHTNING INSTRUMENT PACKAGE (LIP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The Lightning Instrument Package (LIP) consists of 6 rotating vane type electric field sensors along with a central computer to record and monitor the instruments....

  5. Construction and validation of the South African version of the Fear Survey Schedule for Children: an exploratory factor analysis.

    Science.gov (United States)

    Burkhardt, Käthe; Loxton, Helene; Kagee, Ashraf; Ollendick, Thomas H

    2012-09-01

    The Fear Survey Schedule for Children-Revised (Ollendick, 1983) is an 80-item self-report instrument that has been used internationally to asses the number of fears and general level of fearfulness among children. Despite its widespread use, this instrument has not been adapted to the South African context. The present study addressed this gap by means of a 2-phase investigation aimed at developing a South African version of the instrument. In Phase 1, semistructured interviews were conducted with 40 children (7 to 13 years of age). Qualitative data obtained from these interviews were used to construct additional items for inclusion in the South African Fear Survey Schedule for Children-Revised. The modified scale, consisting of 97 items, was then administered to a sample of 646 children between the ages of 7 and 13 years. Further psychometric considerations resulted in the final version of the scale consisting of 74 items with high internal consistency (α=.97). The factor structure was explored by means of principal component analysis with varimax rotation and a 5-factor solution was found to provide the best conceptual fit. The factors identified were as follows: Fear of Death and Danger; Fear of the Unknown; Fear of Small Animals and Minor Threats to Self; Large Animal Fears; and Situational Fears. Differences between the South African version and the original Fear Survey Schedule for Children-Revised are noted and implications for the study of fear in South Africa and other countries are discussed. Copyright © 2012. Published by Elsevier Ltd.

  6. Policy consistency and the achievement of Nigeria's foreign policy ...

    African Journals Online (AJOL)

    This study is an attempt to investigate the policy consistency of Nigeria‟s foreign policy and to understand the basis for this consistency; and also to see whether peacekeeping/peace-enforcement is key instrument in the achievement of Nigeria‟s foreign policy goals. The objective of the study was to examine whether the ...

  7. Psychometric Properties of an Instrument to Measure Mother-Infant Togetherness After Childbirth.

    Science.gov (United States)

    Lawrence, Carol L; Norris, Anne E

    2016-01-01

    The purpose of this research was to evaluate the psychometric properties of a new instrument to measure mother-infant togetherness, Mother-Infant Togetherness Survey (MITS). Stage 1 examined content validity. Stage 2 pretested the readability and understandability and further examined content validity. Stage 3 examined women's ability to accurately self-report on the Delivery Events subscale. Stages 4 and 5 examined construct validity. Good content validity was obtained at the scale/subscale level (CVI = .91-1.00). Internal consistency reliability was evaluated at the scale/subscale level (α = .62-.89). Construct validity was supported with known groups testing and factor analysis. Study findings provide support for the reliability and validity of the MITS. Future research should be done to improve the internal consistency reliability of the Postpartum Events subscale.

  8. Safety climate in Swiss hospital units: Swiss version of the Safety Climate Survey

    Science.gov (United States)

    Gehring, Katrin; Mascherek, Anna C.; Bezzola, Paula

    2015-01-01

    Abstract Rationale, aims and objectives Safety climate measurements are a broadly used element of improvement initiatives. In order to provide a sound and easy‐to‐administer instrument for the use in Swiss hospitals, we translated the Safety Climate Survey into German and French. Methods After translating the Safety Climate Survey into French and German, a cross‐sectional survey study was conducted with health care professionals (HCPs) in operating room (OR) teams and on OR‐related wards in 10 Swiss hospitals. Validity of the instrument was examined by means of Cronbach's alpha and missing rates of the single items. Item‐descriptive statistics group differences and percentage of ‘problematic responses’ (PPR) were calculated. Results 3153 HCPs completed the survey (response rate: 63.4%). 1308 individuals were excluded from the analyses because of a profession other than doctor or nurse or invalid answers (n = 1845; nurses = 1321, doctors = 523). Internal consistency of the translated Safety Climate Survey was good (Cronbach's alpha G erman = 0.86; Cronbach's alpha F rench = 0.84). Missing rates at item level were rather low (0.23–4.3%). We found significant group differences in safety climate values regarding profession, managerial function, work area and time spent in direct patient care. At item level, 14 out of 21 items showed a PPR higher than 10%. Conclusions Results indicate that the French and German translations of the Safety Climate Survey might be a useful measurement instrument for safety climate in Swiss hospital units. Analyses at item level allow for differentiating facets of safety climate into more positive and critical safety climate aspects. PMID:25656302

  9. Traceability of radiation protection instruments

    Science.gov (United States)

    Hino, Y.; Kurosawa, T.

    2007-08-01

    Radiation protection instruments are used in daily measurement of dose and activities in workplaces and environments for safety management. The requirements for calibration certificates with traceability are increasing for these instruments to ensure the consistency and reliabilities of the measurement results. The present traceability scheme of radiation protection instruments for dose and activity measurements is described with related IEC/ISO requirements. Some examples of desirable future calibration systems with recent new technologies are also discussed to establish the traceability with reasonable costs and reliabilities.

  10. Development and Psychometric Evaluation of the HPV Clinical Trial Survey for Parents (CTSP-HPV) Using Traditional Survey Development Methods and Community Engagement Principles.

    Science.gov (United States)

    Cunningham, Jennifer; Wallston, Kenneth A; Wilkins, Consuelo H; Hull, Pamela C; Miller, Stephania T

    2015-12-01

    This study describes the development and psychometric evaluation of HPV Clinical Trial Survey for Parents with Children Aged 9 to 15 (CTSP-HPV) using traditional instrument development methods and community engagement principles. An expert panel and parental input informed survey content and parents recommended study design changes (e.g., flyer wording). A convenience sample of 256 parents completed the final survey measuring parental willingness to consent to HPV clinical trial (CT) participation and other factors hypothesized to influence willingness (e.g., HPV vaccine benefits). Cronbach's a, Spearman correlations, and multiple linear regression were used to estimate internal consistency, convergent and discriminant validity, and predictively validity, respectively. Internal reliability was confirmed for all scales (a ≥ 0.70.). Parental willingness was positively associated (p < 0.05) with trust in medical researchers, adolescent CT knowledge, HPV vaccine benefits, advantages of adolescent CTs (r range 0.33-0.42), supporting convergent validity. Moderate discriminant construct validity was also demonstrated. Regression results indicate reasonable predictive validity with the six scales accounting for 31% of the variance in parents' willingness. This instrument can inform interventions based on factors that influence parental willingness, which may lead to the eventual increase in trial participation. Further psychometric testing is warranted. © 2015 Wiley Periodicals, Inc.

  11. A survey on the high reliability software verification and validation technology for instrumentation and control in NPP.

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kee Choon; Lee, Chang Soo; Dong, In Sook [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-01-01

    This document presents the technical status of the software verification and validation (V and V) efforts to support developing and licensing digital instrumentation and control (I and C) systems in nuclear power plants. We have reviewed codes and standards to be concensus criteria among vendor, licensee and licenser. Then we have described the software licensing procedures under 10 CFR 50 and 10 CFR 52 of the United States cope with the licensing barrier. At last, we have surveyed the technical issues related to developing and licensing the high integrity software for digital I and C systems. These technical issues let us know the development direction of our own software V and V methodology. (Author) 13 refs., 2 figs.,.

  12. Policy Instruments to Improve Energy Performance of Existing Owner Occupied Dwellings

    Directory of Open Access Journals (Sweden)

    Lorraine Colette Murphy

    2016-11-01

    complete range of national instruments available at the time of the survey were studied to present a complete picture. A more detailed description of the methodologies adopted is presented below. Methodology An aim of research was to offer qualified accounts and a deeper analysis of how instruments for energy performance improvement in existing dwellings function. Research components focused on both individual instruments and combinations using a triangulation of methods and sources: expert interviews, a survey and literature review. The first step towards meeting the aim of research was to characterise and assess national instruments in the Netherlands. In the absence of an assessment framework for policy instruments in this domain one was created using elements of the theory based evaluation method and concepts from literature. All national energy performance instruments operating at the time that could influence energy performance improvement for space and water heating in existing dwellings were included in the evaluation. Data was obtained from face to face semi-structured interviews with 19 stakeholders involved in lobbying, designing, implementing and evaluating instruments. Interviewee data was complemented with secondary sources, including; evaluations of the national climate change programme, evaluations of individual instruments, cross country evaluations and European projects in which the Netherlands participated. An online survey of owner-occupiers covering the same instruments as the characterization and assessment of instruments described above was conducted to expand the investigation into instruments. More than 5,000 Dutch owner-occupiers participated in the survey. The survey consisted of 96 questions about energy saving measures adopted within the years preceding the survey. The focus lay on measures that involved significant investment to reduce energy consumed for space and water heating. The questionnaire consisted of multiple choice and open ended

  13. Development of a quality instrument for assessing the spontaneous reports of ADR/ADE using Delphi method in China.

    Science.gov (United States)

    Chen, Lixun; Jiang, Ling; Shen, Aizong; Wei, Wei

    2016-09-01

    The frequently low quality of submitted spontaneous reports is of an increasing concern; to our knowledge, no validated instrument exists for assessing case reports' quality comprehensively enough. This work was conducted to develop such a quality instrument for assessing the spontaneous reports of adverse drug reaction (ADR)/adverse drug event (ADE) in China. Initial evaluation indicators were generated using systematic and literature data analysis. Final indicators and their weights were identified using Delphi method. The final quality instrument was developed by adopting the synthetic scoring method. A consensus was reached after four rounds of Delphi survey. The developed quality instrument consisted of 6 first-rank indicators, 18 second-rank indicators, and 115 third-rank indicators, and each rank indicator has been weighted. It evaluates the quality of spontaneous reports of ADR/ADE comprehensively and quantitatively on six parameters: authenticity, duplication, regulatory, completeness, vigilance level, and reporting time frame. The developed instrument was tested with good reliability and validity, which can be used to comprehensively and quantitatively assess the submitted spontaneous reports of ADR/ADE in China.

  14. Status of aerial survey emergency preparedness and ground support equipment, calibration, and sensitivities

    International Nuclear Information System (INIS)

    Dahlstrom, T.S.

    1986-01-01

    During the course of EG and G Energy Measurements, Inc. history in aerial surveillance, the scope of response has broadened from routine surveys and accident response with aerial systems, to being prepared to respond to any radiological incident with aerial, ground mobile, and hand-held instrumentation. The aerial survey system presently consists of four MBB BO-105 helicopters outfitted with gamma pods and specialized navigation systems (MRS or URS) that allow the operator and pilot to fly well-defined survey lines. Minimum detectable activities (MDA) for various isotopes range from a few tenths of a mCi to 100 mCI for point sources and from 1 to 200 pCi/g for volume sources

  15. Recent high precision surveys at PEP

    International Nuclear Information System (INIS)

    Sah, R.C.

    1980-12-01

    The task of surveying and aligning the components of PEP has provided an opportunity to develop new instruments and techniques for the purpose of high precision surveys. The new instruments are quick and easy to use, and they automatically encode survey data and read them into the memory of an on-line computer. When measurements of several beam elements have been taken, the on-line computer analyzes the measured data, compares them with desired parameters, and calculates the required adjustments to beam element support stands

  16. Assessment of Customer Service in Academic Health Care Libraries (ACSAHL): an instrument for measuring customer service*†

    Science.gov (United States)

    Crossno, Jon E.; Berkins, Brenda; Gotcher, Nancy; Hill, Judith L.; McConoughey, Michelle; Walters, Mitchel

    2001-01-01

    Objectives: In a pilot study, the library had good results using SERVQUAL, a respected and often-used instrument for measuring customer satisfaction. The SERVQUAL instrument itself, however, received some serious and well-founded criticism from the respondents to our survey. The purpose of this study was to test the comparability of the results of SERVQUAL with a revised and shortened instrument modeled on SERVQUAL. The revised instrument, the Assessment of Customer Service in Academic Health Care Libraries (ACSAHL), was designed to better assess customer service in academic health care libraries. Methods: Surveys were sent to clients who had used the document delivery services at three academic medical libraries in Texas over the previous twelve to eighteen months. ACSAHL surveys were sent exclusively to clients at University of Texas (UT) Southwestern, while the client pools at the two other institutions were randomly divided and provided either SERVQUAL or ACSAHL surveys. Results: Results indicated that more respondents preferred the shorter ACSAHL instrument to the longer and more complex SERVQUAL instrument. Also, comparing the scores from both surveys indicated that ACSAHL elicited comparable results. Conclusions: ACSAHL appears to measure the same type of data in similar settings, but additional testing is recommended both to confirm the survey's results through data replication and to investigate whether the instrument applies to different service areas. PMID:11337948

  17. Developments in the use of economic instruments in OECD countries

    International Nuclear Information System (INIS)

    Opschoor, H.

    1994-01-01

    For the period 1987-1993, developments in the environmental policies of OECD countries with respect to the use of economic instruments are compared and the differences analyzed. The focus is on applications in the field of air pollution policies. The comparison is made on the basis of two surveys. To complete the descriptive part, a brief survey is also presented of currently discussed and recently introduced economic instruments. A description of economic instruments as such and a review of rationales for employing economic and financial incentives precede this analysis. The analysis shows that the use of economic instruments has indeed increased since 1987, but the development has not been spectacular. Possible explanations for this are presented. Also, some types of instrument have advanced more than others and the changes differ from one set of countries to another. Product charges (including air pollution-related ones) have become more widely used, especially in Scandinavian countries. Moreover, growing attention is being paid to the use of economic instruments at the international level. The incentive impacts of economic (and other) instruments appear to have received relatively little empirical attention, even though these are an important policy-relevant feature in instrument choice. 23 refs., 5 tabs

  18. Evaluation of psychometric properties of the German Hospital Survey on Patient Safety Culture and its potential for cross-cultural comparisons: a cross-sectional study.

    Science.gov (United States)

    Gambashidze, Nikoloz; Hammer, Antje; Brösterhaus, Mareen; Manser, Tanja

    2017-11-09

    To study the psychometric characteristics of German version of the Hospital Survey on Patient Safety Culture and to compare its dimensionality to other language versions in order to understand the instrument's potential for cross-national studies. Cross-sectional multicentre study to establish psychometric properties of German version of the survey instrument. 73 units from 37 departments of two German university hospitals. Clinical personnel (n=995 responses, response rate 39.6%). Psychometric properties (eg, model fit, internal consistency, construct validity) of the instrument and comparison of dimensionality across different language translations. The instrument demonstrated acceptable to good internal consistency (Cronbach's alpha 0.64-0.88). Confirmatory factor analysis of the original 12-factor model resulted in marginally satisfactory model fit (root mean square error of approximation (RMSEA)=0.05; standardised root mean residual (SRMR)=0.05; comparative fit index (CFI)=0.90; goodness of fit index (GFI)=0.88; Tucker-Lewis Index (TLI)=0.88). Exploratory factor analysis resulted in an alternative eight-factor model with good model fit (RMSEA=0.05; SRMR=0.05; CFI=0.95; GFI=0.91; TLI=0.94) and good internal consistency (Cronbach's alpha 0.73-0.87) and construct validity. Analysis of the dimensionality compared with models from 10 other language versions revealed eight dimensions with relatively stable composition and appearance across different versions and four dimensions requiring further improvement. The German version of Hospital Survey on Patient Safety Culture demonstrated satisfactory psychometric properties for use in German hospitals. However, our comparison of instrument dimensionality across different language versions indicates limitations concerning cross-national studies. Results of this study can be considered in interpreting findings across national contexts, in further refinement of the instrument for cross-national studies and in better

  19. Fragrance allergy and quality of life - development and validation of a disease-specific quality of life instrument.

    Science.gov (United States)

    Heisterberg, Maria V; Menné, Torkil; Johansen, Jeanne D

    2014-02-01

    Fragrance allergy is a lifelong condition that may give rise to permanent or recurrent contact dermatitis and may affect quality of life (QoL). The effect on QoL has not yet been investigated, and no disease-specific QoL instrument for fragrance allergy exists. To develop and validate a disease-specific instrument to investigate QoL among fragrance-allergic subjects. A fragrance QoL instrument (FQL index) was developed on the basis of narratives from 68 fragrance-allergic subjects, and consisted of 13 items. It was tested in a postal survey among 1650 participants patch tested at Gentofte University Hospital (2000–2010). The survey included other QoL instruments [Dermatology Life Quality Index (DLQI) and Short Form 36 (SF36) version 2] and questions on eczema severity (response rate of 66%). A retest was conducted after 3–6 months (response rate of 72.5%). The FQL index showed a significant and strong correlation with the DLQI (rS = 0.70), and disease severity, but a weak correlation with SF36 [mental component summary score, rS = − 0.22; physical component summary score, rS = − 0.31]. Good reliability and responsiveness to changes in disease severity were seen. The FQL index is a good instrument with which to investigate QoL in subjects with fragrance allergy. Good correlations with the DLQI and self-estimated disease severity were seen, and it showed good reliability, reproducibility and ability to distinguish changes in disease severity.

  20. Characterization of HPGe gamma spectrometric detectors systems for Instrumental Neutron Activation Analysis (INAA) at the Colombian Geological Survey

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, O., E-mail: osierra@sgc.gov.co; Parrado, G., E-mail: gparrado@sgc.gov.co; Cañón, Y.; Porras, A.; Alonso, D.; Herrera, D. C.; Peña, M., E-mail: mlpena@sgc.gov.co; Orozco, J. [Colombian Geological Survey, Nuclear Affairs Technical Division, Neutron Activation Analysis Laboratory, Bogota D. C. (Colombia)

    2016-07-07

    This paper presents the progress made by the Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey (SGC in its Spanish acronym), towards the characterization of its gamma spectrometric systems for Instrumental Neutron Activation Analysis (INAA), with the aim of introducing corrections to the measurements by variations in sample geometry. Characterization includes the empirical determination of the interaction point of gamma radiation inside the Germanium crystal, through the application of a linear model and the use of a fast Monte Carlo N-Particle (MCNP) software to estimate correction factors for differences in counting efficiency that arise from variations in sample density between samples and standards.

  1. Tomographic intensity mapping versus galaxy surveys: observing the Universe in H α emission with new generation instruments

    Science.gov (United States)

    Silva, B. Marta; Zaroubi, Saleem; Kooistra, Robin; Cooray, Asantha

    2018-04-01

    The H α line emission is an important probe for a number of fundamental quantities in galaxies, including their number density, star formation rate (SFR), and overall gas content. A new generation of low-resolution intensity mapping (IM) probes, e.g. SPHEREx and CDIM, will observe galaxies in H α emission over a large fraction of the sky from the local Universe till a redshift of z ˜ 6 - 10, respectively. This will also be the target line for observations by the high-resolution Euclid and WFIRST instruments in the z ˜ 0.7-2 redshift range. In this paper, we estimate the intensity and power spectra of the H α line in the z ˜ 0-5 redshift range using observed line luminosity functions (LFs), when possible, and simulations, otherwise. We estimate the significance of our predictions by accounting for the modelling uncertainties (e.g. SFR, extinction, etc.) and observational contamination. We find that IM surveys can make a statistical detection of the full H α emission between z ˜ 0.8 and 5. Moreover, we find that the high-frequency resolution and the sensitivity of the planned CDIM surveys allow for the separation of H α emission from several interloping lines. We explore ways to use the combination of these line intensities to probe galaxy properties. As expected, our study indicates that galaxy surveys will only detect bright galaxies that contribute up to a few per cent of the overall H α intensity. However, these surveys will provide important constraints on the high end of the H α LF and put strong constraints on the active galactic nucleus LF.

  2. [Development of an instrument for the surveillance of quality indicators in specialized training in Preventive Medicine and Public Health].

    Science.gov (United States)

    Gil-Borrelli, Christian Carlo; Latasa, Pello; Reques, Laura; Alemán, Guadalupe

    2015-01-01

    This study describes the process of developing an instrument intended for use in assessing satisfaction with the quality of training in preventive medicine and public health for resident physicians. To develop this instrument, the National Survey of Satisfaction with Medical Residency was adapted by an expert panel consisting of 23 resident physicians in preventive medicine and public health belonging to 9 autonomous communities in Spain. The adaptation of the survey to the specialty rotations included new dimensions and items and was evaluated with a 5-point Likert scale. The most important dimensions were planning and the achievement of specific objectives, supervision, delegation of responsibilities, resources and work environment, personal assessment, encouragement, support, and whether the rotation resulted in a publication or research project, etc. The development and utilization of this tool will enable future trainees in preventive medicine and public health to make an informed choice about their training itineraries. Copyright © 2015 SESPAS. Published by Elsevier Espana. All rights reserved.

  3. The knowledge, efficacy, and practices instrument for oral health providers: a validity study with dental students.

    Science.gov (United States)

    Behar-Horenstein, Linda S; Garvan, Cyndi W; Moore, Thomas E; Catalanotto, Frank A

    2013-08-01

    Valid and reliable instruments to measure and assess cultural competence for oral health care providers are scarce in the literature, and most published scales have been contested due to a lack of item analysis and internal estimates of reliability. The purposes of this study were, first, to develop a standardized instrument to measure dental students' knowledge of diversity, skills in culturally competent patient-centered communication, and use of culture-centered practices in patient care and, second, to provide preliminary validity support for this instrument. The initial instrument used in this study was a thirty-six-item Likert-scale survey entitled the Knowledge, Efficacy, and Practices Instrument for Oral Health Providers (KEPI-OHP). This instrument is an adaption of an initially thirty-three-item version of the Multicultural Awareness, Knowledge, and Skills Scale-Counselor Edition (MAKSS-CE), a scale that assesses factors related to social justice, cultural differences among clients, and cross-cultural client management. After the authors conducted cognitive and expert interviews, focus groups, pilot testing, and item analysis, their initial instrument was reduced to twenty-eight items. The KEPI-OHP was then distributed to 916 dental students (response rate=48.6 percent) across the United States to measure its reliability and assess its validity. Both exploratory and confirmatory factor analyses were conducted to test the scale's validity. The modification of the survey into a sensible instrument with a relatively clear factor structure using factor analysis resulted in twenty items. A scree test suggested three expressive factors, which were retained for rotation. Bentler's comparative fit and Bentler and Bonnett's non-normed indices were 0.95 and 0.92, respectively. A three-factor solution, including efficacy of assessment, knowledge of diversity, and culture-centered practice subscales, comprised of twenty-items was identified. The KEPI-OHP was found to

  4. The development of two postnatal health instruments: one for mothers (M-PHI) and one for fathers (F-PHI) to measure health during the first year of parenting.

    Science.gov (United States)

    Jones, G L; Morrell, C J; Cooke, J M; Speier, D; Anumba, D; Stewart-Brown, S

    2011-09-01

    To develop and psychometrically evaluate two questionnaires measuring both positive and negative postnatal health of mothers (M-PHI) and fathers (F-PHI) during the first year of parenting. The M-PHI and the F-PHI were developed in four stages. Stage 1: Postnatal women's focus group (M-PHI) and postnatal fathers' postal questionnaire (F-PHI); Stage 2: Qualitative interviews; Stage 3: Pilot postal survey and main postal survey; and Stage 4: Test-retest postal survey. The M-PHI consisted of a 29-item core questionnaire with six main scales and five conditional scales. The F-PHI consisted of a 27-item questionnaire with six main scales. All scales achieved good internal reliability (Cronbach's α 0.66-0.87 for M-PHI, 0.72-0.90 for F-PHI). Intraclass correlation coefficients demonstrated high test-retest reliability (0.60-0.88). Correlation coefficients supported the criterion validity of the M-PHI and the F-PHI when tested against the Short-Form-12 (SF-12), Edinburgh Postnatal Depression Scale (EPDS) and the Warwick and Edinburgh Mental Well-Being Scale (WEMWBS). The M-PHI and F-PHI are valid, reliable, parent-generated instruments. These unique instruments will be invaluable for practitioners wishing to promote family-centred care and for trialists and other researchers requiring a validated instrument to measure both positive and negative health during the first postnatal year, as to date no such measurement has existed.

  5. MITS instrumentation error analysis report

    International Nuclear Information System (INIS)

    Nelson, D.W.; Hillon, D.D.

    1980-01-01

    The MITS (Machine Interface Test System) installation consists of three types of process monitoring and control instrumentation: flow, pressure, and temperature. An effort has been made to assess the various instruments used and assign a value to the accuracy that can be expected. Efforts were also made to analyze the calibration and installation procedures to be used and determine how these might effect the system accuracy

  6. Consistency argued students of fluid

    Science.gov (United States)

    Viyanti; Cari; Suparmi; Winarti; Slamet Budiarti, Indah; Handika, Jeffry; Widyastuti, Fatma

    2017-01-01

    Problem solving for physics concepts through consistency arguments can improve thinking skills of students and it is an important thing in science. The study aims to assess the consistency of the material Fluid student argmentation. The population of this study are College students PGRI Madiun, UIN Sunan Kalijaga Yogyakarta and Lampung University. Samples using cluster random sampling, 145 samples obtained by the number of students. The study used a descriptive survey method. Data obtained through multiple-choice test and interview reasoned. Problem fluid modified from [9] and [1]. The results of the study gained an average consistency argmentation for the right consistency, consistency is wrong, and inconsistent respectively 4.85%; 29.93%; and 65.23%. Data from the study have an impact on the lack of understanding of the fluid material which is ideally in full consistency argued affect the expansion of understanding of the concept. The results of the study as a reference in making improvements in future studies is to obtain a positive change in the consistency of argumentations.

  7. Developing and testing the CHORDS: Characteristics of Responsible Drinking Survey.

    Science.gov (United States)

    Barry, Adam E; Goodson, Patricia

    2011-01-01

    Report on the development and psychometric testing of a theoretically and evidence-grounded instrument, the Characteristics of Responsible Drinking Survey (CHORDS). Instrument subjected to four phases of pretesting (cognitive validity, cognitive and motivational qualities, pilot test, and item evaluation) and a final posttest implementation. Large public university in Texas. Randomly selected convenience sample (n  =  729) of currently enrolled students. This 78-item questionnaire measures individuals' responsible drinking beliefs, motivations, intentions, and behaviors. Cronbach α, split-half reliability, principal components analysis and Spearman ρ were conducted to investigate reliability, stability, and validity. Measures in the CHORDS exhibited high internal consistency reliability and strong correlations of split-half reliability. Factor analyses indicated five distinct scales were present, as proposed in the theoretical model. Subscale composite scores also exhibited a correlation to alcohol consumption behaviors, indicating concurrent validity. The CHORDS represents the first instrument specifically designed to assess responsible drinking beliefs and behaviors. It was found to elicit valid and reliable data among a college student sample. This instrument holds much promise for practitioners who desire to empirically investigate dimensions of responsible drinking.

  8. Critical review of directional neutron survey meters

    International Nuclear Information System (INIS)

    Balmer, Matthew J.I.; Gamage, Kelum A.A.; Taylor, Graeme C.

    2014-01-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument. -- Highlights: • We critically review the existing literature into directional survey meters. • Instruments which could be adapted for this purpose are also reviewed. • Investigate the potential of much lighter portable real-time instrument. • Improvements to existing instruments are suggested to improve their design. • Boron-Doped liquid scintillator design is the most promising, but needs further work

  9. Development of an instrument to measure health center (HC) personnel's computer use, knowledge and functionality demand for HC computerized information system in Thailand.

    Science.gov (United States)

    Kijsanayotin, Boonchai; Pannarunothai, Supasit; Speedie, Stuart

    2005-01-01

    Knowledge about socio-technical aspects of information technology (IT) is vital for the success of health IT projects. The Thailand health administration anticipates using health IT to support the recently implemented national universal health care system. However, the national knowledge associate with the socio-technical aspects of health IT has not been studied in Thailand. A survey instrument measuring Thai health center (HC) personnel's computer use, basic IT knowledge and HC computerized information system functionality needs was developed. The instrument reveals acceptable test-retest reliability and reasonable internal consistency of the measures. The future nation-wide demonstration study will benefit from this study.

  10. LUPIN, a new instrument for pulsed neutron fields

    Energy Technology Data Exchange (ETDEWEB)

    Caresana, M. [Politecnico di Milano, Department of Energy, Via Ponzio 34/3, 20133 Milan (Italy); Ferrarini, M. [Politecnico di Milano, Department of Energy, Via Ponzio 34/3, 20133 Milan (Italy); CNAO, Via Privata Campeggi, 27100 Pavia (Italy); Manessi, G.P., E-mail: giacomo.paolo.manessi@cern.ch [CERN, 1211 Geneva 23 (Switzerland); University of Liverpool, Department of Physics, L69 7ZE Liverpool (United Kingdom); Silari, M. [CERN, 1211 Geneva 23 (Switzerland); Varoli, V. [Politecnico di Milano, Department of Energy, Via Ponzio 34/3, 20133 Milan (Italy)

    2013-06-01

    A number of studies focused in the last decades on the development of survey meters to be used in pulsed radiation fields. This is a topic attracting widespread interest for applications such as radiation protection and beam diagnostics in accelerators. This paper describes a new instrument specifically conceived for applications in pulsed neutron fields (PNF). The detector, called LUPIN, is a rem counter type instrument consisting of a {sup 3}He proportional counter placed inside a spherical moderator. It works in current mode with a front-end electronics consisting of a current–voltage logarithmic amplifier, whose output signal is acquired with an ADC and processed on a PC. This alternative signal processing allows the instrument to be used in PNF without being affected by saturation effects. Moreover, it has a measurement capability ranging over many orders of burst intensity. Despite the fact that it works in current mode, it can measure a single neutron interaction. The LUPIN was first calibrated in CERN's calibration laboratory with a PuBe source. Measurements were carried out under various experimental conditions at the Helmholtz-Zentrum in Berlin, in the stray field at various locations of the CERN Proton Synchrotron complex and around a radiotherapy linear accelerator at the S. Raffaele hospital in Milan. The detector can withstand single bursts with values of H⁎(10) up to 16 nSv/burst without showing any saturation effect. It efficiently works in pulsed stray fields, where a conventional rem-counter underestimates by a factor of 2. It is also able to reject the very intense and pulsed photon contribution that often accompanies the neutron field with good reliability. -- Highlights: ► LUPIN is a new detector specifically conceived to work in neutron pulsed fields. ► The detector is a rem counter type instrument working in current mode. ► The performances of the detectors were studied under various experimental conditions. ► The detector

  11. Development and Validation of Culture-Sensitive Physics Learning Environment Survey (CS-PLES

    Directory of Open Access Journals (Sweden)

    Marie Paz E. Morales

    2014-05-01

    Full Text Available The study combined qualitative approaches with quantitative research design to come up with a survey instrument called Culture-Sensitive Physics Learning Environment Survey (CS-PLES.This survey instrument is intended to extract the learners’ beliefs and expectations on the integration of culture and language in the teaching and learning process of physics concepts. Significant contribution of the instrument can be traced to establishing and defining the constructs and categories on how curriculum localization and context-based science learning can be developed aligned with students’ expectations and beliefs. The development process employed non-conventional processes adopted from literature which included pilot study to identify pre-deterministic constructs and specific categories for the items to be included in the survey. Data analysis included descriptive statistics and factor analysis to establish the categories or constructs of the survey instruments. Reliability measures of the instrument and its respective constructs were established for standardization. These categories were intended to aid researchers for an in-depth analysis when the instrument is administered for its purpose. The raw statistical categories were qualitatively paralleled with the pre-deterministic constructs to establish congruence of the survey tool to Instructional Congruence Framework (ICF.

  12. WFIRST: Data/Instrument Simulation Support at IPAC

    Science.gov (United States)

    Laine, Seppo; Akeson, Rachel; Armus, Lee; Bennett, Lee; Colbert, James; Helou, George; Kirkpatrick, J. Davy; Meshkat, Tiffany; Paladini, Roberta; Ramirez, Solange; Wang, Yun; Xie, Joan; Yan, Lin

    2018-01-01

    As part of WFIRST Science Center preparations, the IPAC Science Operations Center (ISOC) maintains a repository of 1) WFIRST data and instrument simulations, 2) tools to facilitate scientific performance and feasibility studies using the WFIRST, and 3) parameters summarizing the current design and predicted performance of the WFIRST telescope and instruments. The simulation repository provides access for the science community to simulation code, tools, and resulting analyses. Examples of simulation code with ISOC-built web-based interfaces include EXOSIMS (for estimating exoplanet yields in CGI surveys) and the Galaxy Survey Exposure Time Calculator. In the future the repository will provide an interface for users to run custom simulations of a wide range of coronagraph instrument (CGI) observations and sophisticated tools for designing microlensing experiments. We encourage those who are generating simulations or writing tools for exoplanet observations with WFIRST to contact the ISOC team so we can work with you to bring these to the attention of the broader astronomical community as we prepare for the exciting science that will be enabled by WFIRST.

  13. Overview of intercalibration of satellite instruments

    Science.gov (United States)

    Chander, G.; Hewison, T.J.; Fox, N.; Wu, X.; Xiong, X.; Blackwell, W.J.

    2013-01-01

    Inter-calibration of satellite instruments is critical for detection and quantification of changes in the Earth’s environment, weather forecasting, understanding climate processes, and monitoring climate and land cover change. These applications use data from many satellites; for the data to be inter-operable, the instruments must be cross-calibrated. To meet the stringent needs of such applications requires that instruments provide reliable, accurate, and consistent measurements over time. Robust techniques are required to ensure that observations from different instruments can be normalized to a common scale that the community agrees on. The long-term reliability of this process needs to be sustained in accordance with established reference standards and best practices. Furthermore, establishing physical meaning to the information through robust Système International d'unités (SI) traceable Calibration and Validation (Cal/Val) is essential to fully understand the parameters under observation. The processes of calibration, correction, stability monitoring, and quality assurance need to be underpinned and evidenced by comparison with “peer instruments” and, ideally, highly calibrated in-orbit reference instruments. Inter-calibration between instruments is a central pillar of the Cal/Val strategies of many national and international satellite remote sensing organizations. Inter-calibration techniques as outlined in this paper not only provide a practical means of identifying and correcting relative biases in radiometric calibration between instruments but also enable potential data gaps between measurement records in a critical time series to be bridged. Use of a robust set of internationally agreed upon and coordinated inter-calibration techniques will lead to significant improvement in the consistency between satellite instruments and facilitate accurate monitoring of the Earth’s climate at uncertainty levels needed to detect and attribute the mechanisms

  14. Proceedings of the Scientific Meeting in Nuclear Instrumentation Engineering

    International Nuclear Information System (INIS)

    Achmad Suntoro; Rony Djokorayono; Ferry Sujatno; Utaja

    2010-11-01

    The Proceeding of the Scientific Meeting in Nuclear Instrumentation Engineering held on Nov, 30, 2010 by the Centre for Nuclear Instrumentation Engineering - National Nuclear Energy Agency. The Proceedings of the Scientific Contains 40 papers Consist of Nuclear Instrumentation Engineering for Industry, Environment, and Nuclear Facilities. (PPIKSN)

  15. Robust Instrumentation[Water treatment for power plant]; Robust Instrumentering

    Energy Technology Data Exchange (ETDEWEB)

    Wik, Anders [Vattenfall Utveckling AB, Stockholm (Sweden)

    2003-08-01

    Cementa Slite Power Station is a heat recovery steam generator (HRSG) with moderate steam data; 3.0 MPa and 420 deg C. The heat is recovered from Cementa, a cement industry, without any usage of auxiliary fuel. The Power station commenced operation in 2001. The layout of the plant is unusual, there are no similar in Sweden and very few world-wide, so the operational experiences are limited. In connection with the commissioning of the power plant a R and D project was identified with the objective to minimise the manpower needed for chemistry management of the plant. The lean chemistry management is based on robust instrumentation and chemical-free water treatment plant. The concept with robust instrumentation consists of the following components; choice of on-line instrumentation with a minimum of O and M and a chemical-free water treatment. The parameters are specific conductivity, cation conductivity, oxygen and pH. In addition to that, two fairly new on-line instruments were included; corrosion monitors and differential pH calculated from specific and cation conductivity. The chemical-free water treatment plant consists of softening, reverse osmosis and electro-deionisation. The operational experience shows that the cycle chemistry is not within the guidelines due to major problems with the operation of the power plant. These problems have made it impossible to reach steady state and thereby not viable to fully verify and validate the concept with robust instrumentation. From readings on the panel of the online analysers some conclusions may be drawn, e.g. the differential pH measurements have fulfilled the expectations. The other on-line analysers have been working satisfactorily apart from contamination with turbine oil, which has been noticed at least twice. The corrosion monitors seem to be working but the lack of trend curves from the mainframe computer system makes it hard to draw any clear conclusions. The chemical-free water treatment has met all

  16. The Measurement of Sexual Harassment: Comparison of the Results of Three Different Instruments

    NARCIS (Netherlands)

    Junger, Marianne

    1990-01-01

    This study examines the results of three instruments developed to measure sexual harassment. Two instruments were used in the Dutch national victimization survey: an oral interview and a written questionnaire. Three issues will be discussed: (1) do both instruments produce the same victimization

  17. SSCL RFQ-DTL Matching Section instrumentation

    International Nuclear Information System (INIS)

    Datte, P.; Aielo, R.; Hayworth, M.

    1993-11-01

    A description of the SSCL RFQ-DTL Matching Section instrumentation is presented with emphasis on design issues and early instrumentation commissioning results. The H - beam energy through the RFQ-DTL matching section is 2.5 MeV, the beam current is 27 mA with a pulse width of 35 Its. The typical beam diameter is 3 mm. The instrumentation consists of three beam position monitors (BPM), a wire scanner, beam loss monitors (BLM), a slit and collector emittance measurement unit (EMU), a current toroid, and a Faraday cup. The instruments were designed to accommodate high current densities, have a large dynamic range with moderate bandwidths, and fit congested spaces

  18. The Iranian version of 12-item Short Form Health Survey (SF-12): factor structure, internal consistency and construct validity.

    Science.gov (United States)

    Montazeri, Ali; Vahdaninia, Mariam; Mousavi, Sayed Javad; Omidvari, Speideh

    2009-09-16

    The 12-item Short Form Health Survey (SF-12) as a shorter alternative of the SF-36 is largely used in health outcomes surveys. The aim of this study was to validate the SF-12 in Iran. A random sample of the general population aged 15 years and over living in Tehran, Iran completed the SF-12. Reliability was estimated using internal consistency and validity was assessed using known groups comparison and convergent validity. In addition, the factor structure of the questionnaire was extracted by performing both exploratory factor analysis (EFA) and confirmatory factor analysis (CFA). In all, 5587 individuals were studied (2721 male and 2866 female). The mean age and formal education of the respondents were 35.1 (SD = 15.4) and 10.2 (SD = 4.4) years respectively. The results showed satisfactory internal consistency for both summary measures, that are the Physical Component Summary (PCS) and the Mental Component Summary (MCS); Cronbach's alpha for PCS-12 and MCS-12 was 0.73 and 0.72, respectively. Known-groups comparison showed that the SF-12 discriminated well between men and women and those who differed in age and educational status (P < 0.001). In addition, correlations between the SF-12 scales and single items showed that the physical functioning, role physical, bodily pain and general health subscales correlated higher with the PCS-12 score, while the vitality, social functioning, role emotional and mental health subscales more correlated with the MCS-12 score lending support to its good convergent validity. Finally the principal component analysis indicated a two-factor structure (physical and mental health) that jointly accounted for 57.8% of the variance. The confirmatory factory analysis also indicated a good fit to the data for the two-latent structure (physical and mental health). In general the findings suggest that the SF-12 is a reliable and valid measure of health related quality of life among Iranian population. However, further studies are needed to

  19. Development and testing of the Youth Alcohol Norms Survey (YANS) instrument to measure youth alcohol norms and psychosocial influences.

    Science.gov (United States)

    Burns, Sharyn K; Maycock, Bruce; Hildebrand, Janina; Zhao, Yun; Allsop, Steve; Lobo, Roanna; Howat, Peter

    2018-05-14

    This study aimed to develop and validate an online instrument to: (1) identify common alcohol-related social influences, norms and beliefs among adolescents; (2) clarify the process and pathways through which proalcohol norms are transmitted to adolescents; (3) describe the characteristics of social connections that contribute to the transmission of alcohol norms; and (4) identify the influence of alcohol marketing on adolescent norm development. The online Youth Alcohol Norms Survey (YANS) was administered in secondary schools in Western Australia PARTICIPANTS: Using a 2-week test-retest format, the YANS was administered to secondary school students (n=481, age=13-17 years, female 309, 64.2%). The development of the YANS was guided by social cognitive theory and comprised a systematic multistage process including evaluation of content and face validity. A 2-week test-retest format was employed. Exploratory factor analysis was conducted to determine the underlying factor structure of the instrument. Test-retest reliability was examined using intraclass correlation coefficient (ICC) and Cohen's kappa. A five-factor structure with meaningful components and robust factorial loads was identified, and the five factors were labelled as 'individual attitudes and beliefs', 'peer and community identity', 'sibling influences', 'school and community connectedness' and 'injunctive norms', respectively. The instrument demonstrated stability across the test-retest procedure (ICC=0.68-0.88, Cohen's kappa coefficient=0.69) for most variables. The results support the reliability and factorial validity of this instrument. The YANS presents a promising tool, which enables comprehensive assessment of reciprocal individual, behavioural and environmental factors that influence alcohol-related norms among adolescents. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise

  20. Measuring decision quality: psychometric evaluation of a new instrument for breast cancer surgery

    Directory of Open Access Journals (Sweden)

    Sepucha Karen R

    2012-06-01

    Full Text Available Abstract Background The purpose of this paper is to examine the acceptability, feasibility, reliability and validity of a new decision quality instrument that assesses the extent to which patients are informed and receive treatments that match their goals. Methods Cross-sectional mail survey of recent breast cancer survivors, providers and healthy controls and a retest survey of survivors. The decision quality instrument includes knowledge questions and a set of goals, and results in two scores: a breast cancer surgery knowledge score and a concordance score, which reflects the percentage of patients who received treatments that match their goals. Hypotheses related to acceptability, feasibility, discriminant validity, content validity, predictive validity and retest reliability of the survey instrument were examined. Results We had responses from 440 eligible patients, 88 providers and 35 healthy controls. The decision quality instrument was feasible to implement in this study, with low missing data. The knowledge score had good retest reliability (intraclass correlation coefficient = 0.70 and discriminated between providers and patients (mean difference 35%, p  Conclusions The decision quality instrument met the criteria of feasibility, reliability, discriminant and content validity in this sample. Additional research to examine performance of the instrument in prospective studies and more diverse populations is needed.

  1. Robotic and Survey Telescopes

    Science.gov (United States)

    Woźniak, Przemysław

    Robotic telescopes are revolutionizing the way astronomers collect their dataand conduct sky surveys. This chapter begins with a discussion of principles thatguide the process of designing, constructing, and operating telescopes andobservatories that offer a varying degree of automation, from instruments remotelycontrolled by observers to fully autonomous systems requiring no humansupervision during their normal operations. Emphasis is placed on designtrade-offs involved in building end-to-end systems intended for a wide range ofscience applications. The second part of the chapter contains descriptions ofseveral projects and instruments, both existing and currently under development.It is an attempt to provide a representative selection of actual systems thatillustrates state of the art in technology, as well as important ideas and milestonesin the development of the field. The list of presented instruments spans the fullrange in size starting from small all-sky monitors, through midrange robotic andsurvey telescopes, and finishing with large robotic instruments and surveys.Explosive growth of telescope networking is enabling entirely new modesof interaction between the survey and follow-up observing. Increasingimportance of standardized communication protocols and software is stressed.These developments are driven by the fusion of robotic telescope hardware,massive storage and databases, real-time knowledge extraction, and datacross-correlation on a global scale. The chapter concludes with examplesof major science results enabled by these new technologies and futureprospects.

  2. Developing a theoretical model and questionnaire survey instrument to measure the success of electronic health records in residential aged care.

    Science.gov (United States)

    Yu, Ping; Qian, Siyu

    2018-01-01

    Electronic health records (EHR) are introduced into healthcare organizations worldwide to improve patient safety, healthcare quality and efficiency. A rigorous evaluation of this technology is important to reduce potential negative effects on patient and staff, to provide decision makers with accurate information for system improvement and to ensure return on investment. Therefore, this study develops a theoretical model and questionnaire survey instrument to assess the success of organizational EHR in routine use from the viewpoint of nursing staff in residential aged care homes. The proposed research model incorporates six variables in the reformulated DeLone and McLean information systems success model: system quality, information quality, service quality, use, user satisfaction and net benefits. Two variables training and self-efficacy were also incorporated into the model. A questionnaire survey instrument was designed to measure the eight variables in the model. After a pilot test, the measurement scale was used to collect data from 243 nursing staff members in 10 residential aged care homes belonging to three management groups in Australia. Partial least squares path modeling was conducted to validate the model. The validated EHR systems success model predicts the impact of the four antecedent variables-training, self-efficacy, system quality and information quality-on the net benefits, the indicator of EHR systems success, through the intermittent variables use and user satisfaction. A 24-item measurement scale was developed to quantitatively evaluate the performance of an EHR system. The parsimonious EHR systems success model and the measurement scale can be used to benchmark EHR systems success across organizations and units and over time.

  3. Multiagency radiation survey and site investigation manual (MARSSIM): Survey design

    International Nuclear Information System (INIS)

    Abelquist, E.W.; Berger, J.D.

    1996-01-01

    This paper describes the MultiAgency Radiation Survey and Site Investigation Manual (MARSSIM) strategy for designing a final status survey. The purpose of the final status survey is to demonstrate that release criteria established by the regulatory agency have been met. Survey design begins with identification of the contaminants and determination of whether the radionuclides of concern exist in background. The decommissioned site is segregated into Class 1, Class 2, and Class 3 areas, based on contamination potential, and each area is further divided into survey units. Appropriate reference areas for indoor and outdoor background measurements are selected. Survey instrumentation and techniques are selected in order to assure that the instrumentation is capable of detecting the contamination at the derived concentration guideline level (DCGL). Survey reference systems are established and the number of survey data points is determined-with the required number of data points distributed on a triangular grid Pattern. Two suitistical tests are used to evaluate data from final status surveys. For contaminants that are b, present in background, the Wilcoxon Rank Sum test is used; for contaminants that are not present in background, the Wilcoxon Signed Rank (or Sign) test is used. The number of data points needed to satisfy these nonparametric tests is based on the contaminant DCGL value, the expected Standard deviation of the contaminant in background and in the survey unit, and the acceptable probability of making Type I and Type II decision errors. The MARSSIM also requires a reasonable level of assurance that any small areas of elevated residual radioactivity that could be significant relative to regulatory limits are not missed during the final status survey. Measurements and sampling on a specified grid size are used to obtain an adequate assurance level that small locations of elevated radioactivity will Still satisfy DCGLs-applicable to small areas

  4. An Instrument to Measure Dental Students' Communication Skills With Patients in Six Specific Circumstances: An Exploratory Factor Analysis.

    Science.gov (United States)

    Aalboe, Joanna A; Schumacher, Mitzi M

    2016-01-01

    The aim of this study was to explore the internal structure of an instrument assessing dental students' confidence in their ability to communicate with patients in six specific circumstances (anxious, in pain, etc.) using exploratory factor analysis. In a Communication in the Dental Health Care Setting course at a U.S. dental school, second-year dental students in two years (2013 and 2014) responded to the six items on a survey instrument. Of the total 123 students, 122 fully completed the instrument, for a response rate of 99%. Analysis of the results identified a unidimensional scale with regards to patient-specific communication self-efficacy and explained 74% of the total variance. The scale had good internal consistency reflected by high Cronbach's alpha (α=0.929, 95% CI [0.907, 0.947]). These findings suggest the instrument may be a useful tool in assessing the development of patient communication skills in second-year dental students following a course in communication. Further exploration utilizing confirmatory analysis, determining predictive validity, and assessing convergent and discriminant evidence is warranted.

  5. Technical requirements on knowledge base and instrumentation system for decision making in plant operation and maintenance

    International Nuclear Information System (INIS)

    Kitamura, Masaharu; Yoshikawa, Shinji; Hasegawa, Makoto

    1998-03-01

    A series of technical surveys and studies are described in this report to examine and identify technical requirements to be posed on knowledge base and instrumentation system as the fundamental in high reliability computational decision making in operation and maintenance of nuclear power plants. Monitoring and diagnosis are focused as the important tasks among the operation/maintenance-related tasks. A concrete monitoring and diagnosis system configuration has been proposed consisting of distributed symptom database and of on-demand measurement subsystem. An prototype of the proposed system configuration has been successfully verified. (author)

  6. Calibration methodology for instruments utilized in X radiation beams, diagnostic level

    International Nuclear Information System (INIS)

    Penha, M. da; Potiens, A.; Caldas, L.V.E.

    2004-01-01

    Methodologies for the calibration of diagnostic radiology instruments were established at the Calibration Laboratory of IPEN. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. The established qualities are recommended by the international standards IEC 1267 and ISO 4037-3. Two ionization chambers were used as reference systems, one with a volume of 30 cm 3 for radiation protection measurements, and the other with a volume of 1 cm 3 for direct beam measurements. Both are traceable to the German Primary Laboratory of Physikalisch-Technische Bundesanstalt (PTB). In the case of calibration of quality control instruments, a non-invasive method using the measurement of the spectrum endpoint was established with a portable gamma and X-ray Intertechnique spectrometer system. The methods were applied to survey meters (radiation protection measurements), ionization chambers (direct beam measurements) and k Vp meters (invasive and non-invasive instruments). (Author)

  7. Calibration methodology for instruments utilized in X radiation beams, diagnostic level

    Energy Technology Data Exchange (ETDEWEB)

    Penha, M. da; Potiens, A.; Caldas, L.V.E. [Instituto de Pesquisas Energeticas e Nucleares, Comissao Nacional de Energia Nuclear, Sao Paulo (Brazil)]. E-mail: mppalbu@ipen.br

    2004-07-01

    Methodologies for the calibration of diagnostic radiology instruments were established at the Calibration Laboratory of IPEN. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. The established qualities are recommended by the international standards IEC 1267 and ISO 4037-3. Two ionization chambers were used as reference systems, one with a volume of 30 cm{sup 3} for radiation protection measurements, and the other with a volume of 1 cm{sup 3} for direct beam measurements. Both are traceable to the German Primary Laboratory of Physikalisch-Technische Bundesanstalt (PTB). In the case of calibration of quality control instruments, a non-invasive method using the measurement of the spectrum endpoint was established with a portable gamma and X-ray Intertechnique spectrometer system. The methods were applied to survey meters (radiation protection measurements), ionization chambers (direct beam measurements) and k Vp meters (invasive and non-invasive instruments). (Author)

  8. Measuring medical students' attitudes and knowledge about geriatrics and gerontology in Brazilian medical students: A comparison of instruments.

    Science.gov (United States)

    Lucchetti, Alessandra Lg; da S Ezequiel, Oscarina; Moreira-Almeida, Alexander; Lucchetti, Giancarlo

    2018-04-14

    To compare instruments available for evaluating attitudes and knowledge about geriatrics and gerontology. This cross-sectional study investigated 83 third-year Brazilian medical students (with exposure to geriatrics and gerontology) and 75 incoming students (with no exposure to this content). We used the University of California at Los Angeles Geriatrics Attitudes Scale, Palmore's Facts on Aging Quiz, modified Maxwell-Sullivan Attitude Survey, Aging Semantic Differential Scale and an instrument assessing their cognitive knowledge in geriatrics. The instruments investigated had moderate-to-high correlations when evaluating similar constructs, had satisfactory or borderline internal consistency for the most part (Cronbach's α: 0.62-0.94) and were capable of discriminating between students exposed or not to practical and theoretical content. Our findings reinforce previous studies that these scales are capable of differentiating students who have or have not had exposure/intervention and, in general, seem to be assessing different constructs. © 2018 AJA Inc.

  9. Gender and Participation in High School and College Instrumental Jazz Ensembles

    Science.gov (United States)

    McKeage, Kathleen M.

    2004-01-01

    This study is an examination of the relationship between gender and participation in high school and college instrumental jazz ensembles. Student demographic and attitudinal information was collected using the researcher-designed Instrumental Jazz Participation Survey (IJPS). Undergraduate college band students (N = 628) representing 15 programs…

  10. Swift Burst Alert Telescope (BAT) Instrument Response

    International Nuclear Information System (INIS)

    Parsons, A.; Barthelmy, S.; Cummings, J.; Gehrels, N.; Hullinger, D.; Krimm, H.; Markwardt, C.; Tueller, J.; Fenimore, E.; Palmer, D.; Sato, G.; Takahashi, T.; Nakazawa, K.; Okada, Y.; Takahashi, H.; Suzuki, M.; Tashiro, M.

    2004-01-01

    The Burst Alert Telescope (BAT), a large coded aperture instrument with a wide field-of-view (FOV), provides the gamma-ray burst triggers and locations for the Swift Gamma-Ray Burst Explorer. In addition to providing this imaging information, BAT will perform a 15 keV - 150 keV all-sky hard x-ray survey based on the serendipitous pointings resulting from the study of gamma-ray bursts, and will also monitor the sky for transient hard x-ray sources. For BAT to provide spectral and photometric information for the gamma-ray bursts, the transient sources and the all-sky survey, the BAT instrument response must be determined to an increasingly greater accuracy. This paper describes the spectral models and the ground calibration experiments used to determine the BAT response to an accuracy suitable for gamma-ray burst studies

  11. Development and evaluation of an instrument to measure community pharmacists' self-efficacy beliefs about communicating with Spanish-speaking patients.

    Science.gov (United States)

    Young, Henry N; Hwang, Monica J; Dilworth, Thomas J; Mott, David; Cox, Elizabeth D; Moreno, Megan A

    2011-12-01

    Hispanics are the largest growing population in the United States, and their use of prescription medications can be influenced by the education and counseling they receive from pharmacists. However, little is known about pharmacists' communication with patients who speak Spanish or factors that can influence such communication. The objective of the study was to develop and validate an instrument to measure pharmacists' self-efficacy in communicating with Spanish-speaking patients. An initial pool of 15 items developed from previous research and suggestions from communication experts and practicing pharmacists was subjected to cognitive interviewing. Nine retained items were administered to 1022 licensed pharmacists by mail survey. Summary statistics and exploratory factor analysis (EFA) were conducted. Retained factors were determined by the examination of eigenvalues and scree test results. Cronbach's alpha coefficients were calculated to assess internal consistency. A total of 540 community pharmacists completed the survey. Item means ranged from 2.93±1.47 to 1.58±0.88 based on a 5-point scale (1: not at all confident to 5: extremely confident). EFA resulted in a 2-factor solution, accounting for 71% of the variance. The 2 factors consisted of health and drug information (alpha=0.92) and opening the encounter (alpha=0.75). The alpha for the overall scale was 0.88. The results provide evidence to support the reliability and validity of an instrument to measure pharmacists' self-efficacy beliefs about communicating with Spanish-speaking patients in community practice. Practitioners and researchers may use this instrument to inform pharmacy education, pharmacy practice improvement, and research efforts around communicating with Spanish-speaking clients. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. CRiSP: An Instrument for Assessing Student Perceptions of Classroom Response Systems

    Science.gov (United States)

    Richardson, Alice M.; Dunn, Peter K.; McDonald, Christine; Oprescu, Florin

    2015-08-01

    This paper describes the development and validation of an instrument for evaluating classroom response systems (CRS). While a number of studies evaluating CRS have been published to date, no standardised instrument exists as a means of evaluating the impact of using the CRS. This means that comparing the different systems, or evaluating the benefits of using the CRS in different ways or settings, is very difficult despite the number of published reports, as indicated by Kay and LeSage (2009). An instrument was developed, called the classroom response system perceptions (CRiSP) questionnaire, which allows the evaluation of varied CRS on three scales: the usability; the impact on student engagement; and the impact on student learning. The development of CRiSP was undertaken in three universities, using different CRS, and evaluated through focus groups, one-on-one interviews and a factor analysis of the survey responses. We found no evidence of difference on the scales according to gender or age groups. The final CRiSP questionnaire consists of 26 base questions, with additional optional questions available. This paper proposes that the CRiSP Questionnaire could, in its current state or with minor changes, be used to evaluate the impact on learning of other classroom technologies also.

  13. Big Surveys, Big Data Centres

    Science.gov (United States)

    Schade, D.

    2016-06-01

    Well-designed astronomical surveys are powerful and have consistently been keystones of scientific progress. The Byurakan Surveys using a Schmidt telescope with an objective prism produced a list of about 3000 UV-excess Markarian galaxies but these objects have stimulated an enormous amount of further study and appear in over 16,000 publications. The CFHT Legacy Surveys used a wide-field imager to cover thousands of square degrees and those surveys are mentioned in over 1100 publications since 2002. Both ground and space-based astronomy have been increasing their investments in survey work. Survey instrumentation strives toward fair samples and large sky coverage and therefore strives to produce massive datasets. Thus we are faced with the "big data" problem in astronomy. Survey datasets require specialized approaches to data management. Big data places additional challenging requirements for data management. If the term "big data" is defined as data collections that are too large to move then there are profound implications for the infrastructure that supports big data science. The current model of data centres is obsolete. In the era of big data the central problem is how to create architectures that effectively manage the relationship between data collections, networks, processing capabilities, and software, given the science requirements of the projects that need to be executed. A stand alone data silo cannot support big data science. I'll describe the current efforts of the Canadian community to deal with this situation and our successes and failures. I'll talk about how we are planning in the next decade to try to create a workable and adaptable solution to support big data science.

  14. Challenges in Cultivating EOSDIS User Survey Participation

    Science.gov (United States)

    Boquist, C. L.; Sofinowski, E. J.; Walter, S.

    2011-12-01

    Since 2004 NASA has surveyed users of its Earth Observing System Data and Information System (EOSDIS) to determine user satisfaction with its services. The surveys have been conducted by CFI Group under contract with the Federal Consulting Group, Executive Agent in government for the American Customer Satisfaction Index (ACSI). The purpose of these annual surveys is to help EOSDIS and the data centers assess current status and improve future services. The survey questions include demographic and experiential questions in addition to the ACSI and EOSDIS specific rating questions. In addition to customer satisfaction, analysis of each year's results has provided insight into the survey process. Although specific questions have been added, modified, or deleted to reflect changes to the EOSDIS system and processes, the model rating questions have remained the same to ensure consistency for evaluating cross year trends. Working with the CFI Group, we have refined the invitation and questions to increase clarity and address the different ways diverse groups of users access services at EOSDIS data centers. We present challenges in preparing a single set of questions that go to users with backgrounds in many Earth science disciplines. These users may have contacted any of the 12 EOSDIS data centers for information or may have accessed data or data products from many kinds of aircraft and satellite instruments. We discuss lessons learned in preparing the invitation and survey questions and the steps taken to make the survey easier to complete and to encourage increased participation.

  15. Development and validation of a new survey: Perceptions of Teaching as a Profession (PTaP)

    Science.gov (United States)

    Adams, Wendy

    2017-01-01

    To better understand the impact of efforts to train more science teachers such as the PhysTEC Project and to help with early identification of future teachers, we are developing the survey of Perceptions of Teaching as a Profession (PTaP) to measure students' views of teaching as a career, their interest in teaching and the perceived climate of physics departments towards teaching as a profession. The instrument consists of a series of statements which require a response using a 5-point Likert-scale and can be easily administered online. The survey items were drafted by a team of researchers and physics teacher candidates and then reviewed by an advisory committee of 20 physics teacher educators and practicing teachers. We conducted 27 interviews with both teacher candidates and non-teaching STEM majors. The survey was refined through an iterative process of student interviews and item clarification until all items were interpreted consistently and answered for consistent reasons. In this presentation the preliminary results from the student interviews as well as the results of item analysis and a factor analysis on 900 student responses will be shared.

  16. Human factors aspects of advanced instrumentation in the nuclear industry

    International Nuclear Information System (INIS)

    Carter, R.J.

    1989-01-01

    An important consideration in regards to the use of advanced instrumentation in the nuclear industry is the interface between the instrumentation system and the human. A survey, oriented towards identifying the human factors aspects of digital instrumentation, was conducted at a number of United States (US) and Canadian nuclear vendors and utilities. Human factors issues, subsumed under the categories of computer-generated displays, controls, organizational support, training, and related topics were identified. 20 refs., 2 tabs

  17. Automated extinction monitor for the NLOT site survey

    Science.gov (United States)

    Kumar Sharma, Tarun

    In order to search a few potential sites for the National Large Optical Telescope (NLOT) project, we have initiated a site survey program. Since, most of instruments used for the site survey are custom made, we also started developing our own site characterization instruments. In this process we have designed and developed a device called Automated Extinction Monitor (AEM) and installed the same at IAO, Hanle. The AEM is a small wide field robotic telescope, dedicated to record atmospheric extinction in one or more photometric bands. It gives very accurate statistics of the distribution of photometric nights. In addition to this, instrument also provides the measurement of sky brightness. Here we briefly describe overall instrument and initial results obtained.

  18. Development of a patient safety climate survey for Chinese hospitals: cross-national adaptation and psychometric evaluation.

    Science.gov (United States)

    Zhu, Junya; Li, Liping; Zhao, Hailei; Han, Guangshu; Wu, Albert W; Weingart, Saul N

    2014-10-01

    Existing patient safety climate instruments, most of which have been developed in the USA, may not accurately reflect the conditions in the healthcare systems of other countries. To develop and evaluate a patient safety climate instrument for healthcare workers in Chinese hospitals. Based on a review of existing instruments, expert panel review, focus groups and cognitive interviews, we developed items relevant to patient safety climate in Chinese hospitals. The draft instrument was distributed to 1700 hospital workers from 54 units in six hospitals in five Chinese cities between July and October 2011, and 1464 completed surveys were received. We performed exploratory and confirmatory factor analyses and estimated internal consistency reliability, within-unit agreement, between-unit variation, unit-mean reliability, correlation between multi-item composites, and association between the composites and two single items of perceived safety. The final instrument included 34 items organised into nine composites: institutional commitment to safety, unit management support for safety, organisational learning, safety system, adequacy of safety arrangements, error reporting, communication and peer support, teamwork and staffing. All composites had acceptable unit-mean reliabilities (≥0.74) and within-unit agreement (Rwg ≥0.71), and exhibited significant between-unit variation with intraclass correlation coefficients ranging from 9% to 21%. Internal consistency reliabilities ranged from 0.59 to 0.88 and were ≥0.70 for eight of the nine composites. Correlations between composites ranged from 0.27 to 0.73. All composites were positively and significantly associated with the two perceived safety items. The Chinese Hospital Survey on Patient Safety Climate demonstrates adequate dimensionality, reliability and validity. The integration of qualitative and quantitative methods is essential to produce an instrument that is culturally appropriate for Chinese hospitals

  19. Validation of an instrument to measure older adults' expectations regarding movement (ERM.

    Directory of Open Access Journals (Sweden)

    Nabila Dahodwala

    Full Text Available BACKGROUND: Many individuals with Parkinson's disease are not diagnosed and treated. Attitudes about aging and related help-seeking may affect the timely diagnosis of Parkinson's disease. Our objectives were to develop measures of older adults' expectations regarding movement with aging, specifically related to parkinsonism, and their beliefs about seeking healthcare for the diagnosis and treatment of parkinsonism. METHODS: We established content and face validity from interviews with experts, review of the literature, and pre-testing with key informants. Two 9-item instruments resulted: Expectations Regarding Movement (ERM and Healthcare Seeking Beliefs for parkinsonism (HSB. These instruments were administered to 210 older adults at senior centers to investigate internal consistency and construct validity. RESULTS: 192 (91% of the older adults completed more than 90% of the survey. The mean age was 76; 17 (9% reported parkinsonism. Both scales demonstrated good internal consistency (α = 0.90. Factor analysis supported construct validity of the ERM and HSB scores. Older age, lower education, worse self-reported health and African American race each were associated with lower ERM scores, but not HSB scores. CONCLUSION: The ERM, a brief measure of expectations regarding movement with aging, shows reliability and validity. This scale may be useful in identifying older adults at increased risk for under-identification of Parkinson's disease. Further work is needed to measure healthcare seeking for parkinsonism.

  20. Research and Development on a Public Attitude Instrument for Stuttering

    Science.gov (United States)

    St. Louis, Kenneth O.

    2012-01-01

    This paper summarizes research associated with the development of the "Public Opinion Survey of Human Attributes-Stuttering" ("POSHA-S"), a survey instrument designed to provide a worldwide standard measure of public attitudes toward stuttering. Pilot studies with early experimental prototypes of the "POSHA-S" are summarized that relate to…

  1. Non-process instrumentation surveillance and test reduction

    International Nuclear Information System (INIS)

    Ferrell, R.; LeDonne, V.; Donat, T.; Thomson, I.; Sarlitto, M.

    1993-12-01

    Analysis of operating experience, instrument failure modes, and degraded instrument performance has led to a reduction in Technical Specification surveillance and test requirements for nuclear power plant process instrumentation. These changes have resulted in lower plant operations and maintenance (O ampersand M) labor costs. This report explores the possibility of realizing similar savings by reducing requirements for non-process instrumentation. The project team reviewed generic Technical Specifications for the four major US nuclear steam supply system (NSSS) vendors (Westinghouse, General Electric, Combustion Engineering, and Babcock ampersand Wilcox) to identify nonprocess instrumentation for which surveillance/test requirements could be reduced. The team surveyed 10 utilities to identify specific non-process instrumentation at their plants for which requirements could be reduced. The team evaluated utility analytic approaches used to justify changes in surveillance/test requirements for process equipment to determine their applicability to non-process instrumentation. The report presents a prioritized list of non-process instrumentation systems suitable for surveillance/test requirements reduction. The top three systems in the list are vibration monitors, leak detection monitors, and chemistry monitors. In general, most non-process instrumentation governed by Technical Specification requirements are candidates for requirements reduction. If statistical requirements are somewhat relaxed, the analytic approaches previously used to reduce requirements for process instrumentation can be applied to non-process instrumentation. The report identifies as viable the technical approaches developed and successfully used by Southern California Edison, Arizona Public Service, and Boston Edison

  2. Argonne National Laboratory's thermal plume measurements: instruments and techniques

    International Nuclear Information System (INIS)

    Van Loon, L.S.; Frigo, A.A.; Paddock, R.A.

    1977-12-01

    Instrumentation and techniques were developed at Argonne National Laboratory for measuring the three-dimensional temperature structure of thermal plumes from power plants, along with the limnological, meteorological, and plant operating conditions affecting their behavior. The equipment and procedures were designed to provide field data for use in evaluating predictive models that describe thermal plume behavior, and over 100 sets of these data have been collected. The instrument systems and techniques employed in a typical thermal discharge survey are highly integrated. Continuous monitoring of ambient and plant conditions is coupled with plume mapping from a moving survey boat. The instantaneous location of the boat together with subsurface temperature measurements from a towed thermistor chain provide a quasisynoptic view of the plume structure. Real-time, onboard display of the boat path and vertical temperatures supply feedback to investigators for determining the extent and spatial resolution of measurements required. The unique design, reliability, accuracy, calibration, and historical development of the components of these integrated systems are described. Survey system interfaces with data handling and processing techniques are also explained. Special supportive studies to investigate plume dynamics, values of eddy diffusivities, time-temperature histories of water parcels in thermal plumes, and rapid changes in plume shape are also described along with instrumentation used

  3. Plane and geodetic surveying

    CERN Document Server

    Johnson, Aylmer

    2014-01-01

    IntroductionAim And ScopeClassification Of SurveysThe Structure Of This BookGeneral Principles Of SurveyingErrorsRedundancyStiffnessAdjustmentPlanning And Record KeepingPrincipal Surveying ActivitiesEstablishing Control NetworksMappingSetting OutResectioningDeformation MonitoringAngle MeasurementThe Surveyor's CompassThe ClinometerThe Total StationMaking ObservationsChecks On Permanent AdjustmentsDistance MeasurementGeneralTape MeasurementsOptical Methods (Tachymetry)Electromagnetic Distance Measurement (EDM)Ultrasonic MethodsGNSSLevellingTheoryThe InstrumentTechniqueBookingPermanent Adjustmen

  4. Instrument specifications and geophysical records for airborne electromagnetic survey of parts of Iron, Baraga, and Dickson Counties, Michigan

    Science.gov (United States)

    Heran, William D.; Smith, Bruce D.

    1980-01-01

    The data presented herein is from an airborne electromagnetic INPUT* survey conducted by Geoterrex Limited of Canada for the U.S. Geological Survey. The survey area is located in the central part of the Upper Peninsula of Michigan, within parts of Iron, Baraga, and Dickinson Counties. The general area covered is between 46°00' and 46°30' latitude and 88°00' and 88°30' longitude (fig. 1).The INPUT survey was flown as part of a U.S. Geological Survey CUSMAP (Conterminous United States Mineral Appraisal Program) project focusing on the Iron River 2° quadrangle. The survey was flown in order to provide geophysical information which will aid in an integrated geological assessment of mineral potentials of this part of the Iron River 2° quadrangle. The flight line spacing was chosen to maximize the areal coverage without a loss of resolution of major lithologic and structural features.East-west flight lines were flown 400 feet above ground at 1/2 mile intervals. Aerial photos were used for navigation, and the flight path was recorded on continuous-strip film. A continuously recording total field ground magnetic station was used to monitor variations in the Earth's magnetic field. One north-south line was flown to provide a tie for the magnetic data, which was recorded simultaneously with the electromagnetic data by a sensor mounted in the tail of the aircraft. This report is one of two open-file reports. The map in the other report Heran and Smith (1980) shows locations of the fiducial points, the flight lines, preliminary locations of anomalies and conductive zones; all plotted on an air photomosaic. The latitude and longitude ticks marked on this map are only approximate due to distortion in air photos used to recover the flight line position. This map is preliminary and is not to be considered a final interpretation. The present report contains a description of the instrument specifications, a copy of the ground station magnetic data, and a record of the

  5. Ethical Considerations for Data Collection Using Surveys.

    Science.gov (United States)

    Hammer, Marilyn J

    2017-03-01

    Surveys are widely used instruments to collect research data. Although surveys may appear relatively benign and easily unlinked to participants, considerations for the ethical conduct of research with surveys are important. Maintaining scientific rigor is essential. This article explores ethical tenets in relation to informed consent and scientific consent when using surveys.

  6. Calibration of a radiation survey meter using Cs-137 gamma source

    International Nuclear Information System (INIS)

    Khalid, R. O.

    2005-07-01

    The survey instrument smartIon was calibrated at the Secondary Standard Dosimetry Laboratory, Sudan Atomic Energy Commission, in terms of kerma, free in air using Cs-137 gamma radiation. All the calibrations were performed using the reference instrument spherical ionization chamber LS-01. This reference instrument has been calibrated at the International Atomic Energy Agency, Vienna for x-rays, 137 Cs and 60 Co gamma radiation. The air kerma calibration factors for the instrument were determined as the ratio of the dose rates obtained with the reference standard chamber LS-01 and the dose rates of the instrument under calibration. The uncertainties for the survey meter smartIon and another survey meter RADOS were obtained and the results compared with the uncertainty for the reference standard chamber. Also, the values of dose rates were obtained for various angles of the incident beam, by changing the angle by which the radiation was incident on the sensitive point of the instrument.(Author)

  7. ICA Communication Audit Survey Instrument: 1977 Organizational Norms.

    Science.gov (United States)

    Goldhaber, Gerald M.; And Others

    Section one of this paper describes the history and development of the "communicaton audit," a system for assessing communication effectiveness in organizations, by the International Communication Association. Section two describes the 16 audits conducted so far and the overall demographic characteristics of the current survey data bank.…

  8. TROPOMI and TROPI: UV/VIS/NIR/SWIR instruments

    NARCIS (Netherlands)

    Levelt, P.F.; Oord, G.H.J. van den; Dobber, M.; Eskes, H.; Weele, M. van; Veefkind, P.; Oss, R. van; Aben, I.; Jongma, R.T.; Landgraf, J.; Vries, J. de; Visser, H.

    2006-01-01

    TROPOMI (Tropospheric Ozone-Monitoring Instrument) is a five-channel UV-VIS-NIR-SWIR non-scanning nadir viewing imaging spectrometer that combines a wide swath (114°) with high spatial resolution (10 × 10 km 2). The instrument heritage consists of GOME on ERS-2, SCIAMACHY on Envisat and, especially,

  9. Minimum detectable activities of contamination control survey equipment

    International Nuclear Information System (INIS)

    Goles, R.W.; Baumann, B.L.; Johnson, M.L.

    1991-08-01

    The Instrumentation ampersand External Dosimetry (I ampersand ED) Section of the Health Physics Department at the Pacific Northwest Laboratory (PNL) has performed a series of tests to determine the ability of portable survey instruments used at Hanford to detect radioactive contamination at levels required by DOE 5480.11. This semi-empirical study combines instrumental, statistical, and human factors as necessary to derive operational detection limits. These threshold detection values have been compared to existing contamination control requirements, and detection deficiencies have been identified when present. Portable survey instruments used on the Hanford Site identify the presence of radioactive surface contamination based on the detection of α-, β-, γ-, and/or x-radiation. However, except in some unique circumstances, most contamination monitors in use at Hanford are configured to detect either α-radiation alone or β- and γ-radiation together. Testing was therefore conducted on only these two categories of radiation detection devices. Nevertheless, many of the results obtained are generally applicable to all survey instruments, allowing performance evaluations to be extended to monitoring devices which are exclusively γ- and/or x-ray- sensitive. 6 figs., 2 tabs

  10. Radiation survey meters used for environmental monitoring

    International Nuclear Information System (INIS)

    Bjerke, H.; Sigurdsson, T.; Meier Pedersen, K.; Grindborg, J.-E.; Persson, L.; Siiskonen, T.; Hakanen, A.; Kosunen, A.

    2012-01-01

    The Nordic dosimetry group set up the GammaRate project to investigate how its expertise could be used to assure appropriate usage of survey meters in environmental monitoring. Considerable expertise in calibrating radiation instruments exists in the Nordic radiation protection authorities. The Swedish, Finnish, Danish and Norwegian authorities operate Secondary Standard Dosimetry Laboratories (SSDLs) that provide users with calibration traceable to internationally recognised primary standards. These authorities together with the Icelandic authorities have formally cooperated since 2002 in the field of radiation dosimetry. Dosimetry is the base for assesment of risk from ionising radiation and calibration of instruments is an imported part in dosimetry. The Nordic dosimetry group has been focused on cancer therapy. This work extends the cooperation to the dosimetry of radiation protection and environmental monitoring. This report contains the formal, theoretical and practical background for survey meter measurements. Nordic standards dosimetry laboratories have the capability to provide traceable calibration of instruments in various types of radiation. To verify and explore this further in radiation protection applications a set of survey instruments were sent between the five Nordic countries and each of the authority asked to provide a calibration coefficient for all instruments. The measurement results were within the stated uncertainties, except for some results from NRPA for the ionchamber based instrument. The comparison was shown to be a valuable tool to harmonize the calibration of radiation protection instruments in the Nordic countries. Dosimetry plays an important role in the emergency situations, and it is clear that better traceability and harmonised common guidelines will improve the emergency preparedness and health. (Author)

  11. Radiation survey meters used for environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bjerke, H. (ed.) (Norwegian Radiation Protection Authority, NRPA (Norway)); Sigurdsson, T. (Icelandic Radiation Safety Authority, Geislavarnir Rikisins, GR (IS)); Meier Pedersen, K. (National Board of Health, Statens Institut for Straalebeskyttelse (SIS) (Denmark)); Grindborg, J.-E.; Persson, L. (Swedish Radiation Safety Authority, Straalsaekerhetsmyndigheten (SSM) (Sweden)); Siiskonen, T.; Hakanen, A.; Kosunen, A. (Radiation and Nuclear Safety Authority, Saeteilyturvakeskus (STUK) (Finland))

    2012-01-15

    The Nordic dosimetry group set up the GammaRate project to investigate how its expertise could be used to assure appropriate usage of survey meters in environmental monitoring. Considerable expertise in calibrating radiation instruments exists in the Nordic radiation protection authorities. The Swedish, Finnish, Danish and Norwegian authorities operate Secondary Standard Dosimetry Laboratories (SSDLs) that provide users with calibration traceable to internationally recognised primary standards. These authorities together with the Icelandic authorities have formally cooperated since 2002 in the field of radiation dosimetry. Dosimetry is the base for assesment of risk from ionising radiation and calibration of instruments is an imported part in dosimetry. The Nordic dosimetry group has been focused on cancer therapy. This work extends the cooperation to the dosimetry of radiation protection and environmental monitoring. This report contains the formal, theoretical and practical background for survey meter measurements. Nordic standards dosimetry laboratories have the capability to provide traceable calibration of instruments in various types of radiation. To verify and explore this further in radiation protection applications a set of survey instruments were sent between the five Nordic countries and each of the authority asked to provide a calibration coefficient for all instruments. The measurement results were within the stated uncertainties, except for some results from NRPA for the ionchamber based instrument. The comparison was shown to be a valuable tool to harmonize the calibration of radiation protection instruments in the Nordic countries. Dosimetry plays an important role in the emergency situations, and it is clear that better traceability and harmonised common guidelines will improve the emergency preparedness and health. (Author)

  12. Chinese version of the Global Youth Tobacco Survey: cross-cultural instrument adaptation

    Directory of Open Access Journals (Sweden)

    Chiou Hung-Yi

    2008-04-01

    Full Text Available Abstract Background Tobacco smoking poses public health concerns because of its high risk for many chronic diseases. Most smokers begin using tobacco in their teens and recent reports indicate that smoking prevalence is climbing among youth. The Global Youth Tobacco Survey (GYTS is a worldwide, school-based, tobacco-specific survey, but cross-cultural differences limit its effectiveness in international studies. Specifically, the GYTS assesses not only the prevalence of smoking, but also tobacco-related attitudes, school curricula, and advertisements, which are culturally influenced. Therefore, we conducted this study to develop a Chinese version of the GYTS for both national surveillance and international comparison. Methods The original English GYTS was translated and back translated using a cross-cultural adaptation process. The comprehensiveness and feasibility of using the Chinese-version GYTS were reviewed by a panel of 6 tobacco-control experts. The understandability and cultural relevance of the Chinese-version GYTS were discussed in a focus group of 5 schoolteachers and 8 students. The expert and focus group feedback was incorporated into a final Chinese version of the GYTS, which was administered to 382 students throughout Taiwan by multi-stage sampling from 10 randomly selected schools. Results The internal consistency (Cronbach's alpha for the GYTS subscales (smoking susceptibility, attitude toward smoking, and media messages about smoking ranged from 0.70 to 0.94. The internal logical agreement of responses ranged from 85.3 to 99.2%. Conclusion The Chinese version of the GYTS has good reliability and validity and can serve as the foundation for international comparison and tobacco control in Chinese-speaking communities.

  13. Consistency of Students' Conceptions of Wave Propagation: Findings from a Conceptual Survey in Mechanical Waves

    Science.gov (United States)

    Tongchai, Apisit; Sharma, Manjula Devi; Johnston, Ian D.; Arayathanitkul, Kwan; Soankwan, Chernchok

    2011-01-01

    We recently developed a multiple-choice conceptual survey in mechanical waves. The development, evaluation, and demonstration of the use of the survey were reported elsewhere [A. Tongchai et al. Int. J. Sci. Educ. 31 2437 (2009)]. We administered the survey to 902 students from seven different groups ranging from high school to second year…

  14. Community Collectivization and Consistent Condom Use Among Female Sex Workers in Southern India: Evidence from Two Rounds of Behavioral Tracking Surveys.

    Science.gov (United States)

    Vejella, Shanti; Patel, Sangram Kishor; Saggurti, Niranjan; Prabhakar, Parimi

    2016-04-01

    Community collectivization is an integral part of condom use and HIV risk reduction interventions among key population. This study assesses community collectivization among female sex workers (FSWs), and explores its relationship with sex workers' consistent condom use (CCU) with different partners considering the interaction effect of time and collectivization. Data were drawn from two rounds of cross-sectional surveys collected during 2010 (N1 = 1986) and 2012 (N2 = 1973) among FSWs in Andhra Pradesh, India. Results of the multiple logistic regression analysis show that, CCU with regular and occasional clients increased over the inter-survey period among FSWs with a high collective efficacy (AOR 2.9 and 6.1) and collective agency (AOR 14.4 and 19.0) respectively. The association of high levels of collectivization with CCU and self-efficacy for condom use are central to improve the usefulness and sustainability of HIV prevention programs worldwide.

  15. The relevance of surveying content in mining engineering education

    African Journals Online (AJOL)

    Tomi Oshokoya

    The paper will highlight the surveying content that is relevant to the mining engineering ... This article attempts to answer the question as to what ... mechanical and electrical engineering, surveying, marketing and financial .... an overview of what surveying is, its principles, surveying instrumentation and surveying.

  16. Towards an Enterprise Architecture Benefits Measurement Instrument

    NARCIS (Netherlands)

    Dr.ir. Raymond Slot; Henk Plessius; Marlies Steenbergen, van

    2015-01-01

    Author supplied: Based on the Enterprise Architecture Value Framework (EAVF) - a generic framework to classify benefits of Enterprise Architecture (EA) - a measurement instrument for EA benefits has been developed and tested in a survey with 287 respondents. In this paper we present the results of

  17. Development of an instrument to measure student attitudes toward science fairs

    Science.gov (United States)

    Huddleston, Claudia A.

    Science fairs are woven into the very fabric of science instruction in the United States and in other countries. Even though thousands of students participate in science fairs every year, no instrument to measure student attitudes toward partaking in this hands-on learning experience has been fully developed and available for school administrators and teachers to assess the perceived value that current students attribute to participation in science fairs. Therefore, the purpose of this study was to continue the development and refinement of an instrument that measured student attitudes towards science fairs based on an unpublished instrument created by Michael (2005). The instrument developed and tested using 110 students at two different middle schools in southwest Virginia. The instrument consisted of 45 questions. After applying a principal component factor analysis, the instrument was reduced to two domains, enjoyment and value. The internal consistency of the instrument was calculated using Cronbach's alpha and showed good internal consistency of .89 between the two domains. Further analysis was conducted using a Pearson product-moment test and showed a significant positive correlation between enjoyment and value (r = .78). Demographic information was explored concerning the domains using a series of statistical tests, and results revealed no significant differences among race and science fair category. However, a significant difference was found among gender and students who won awards and those who did not. The conclusion was that further development and refinement of the instrument should be conducted.

  18. A guide on instrument of biochemistry and molecular biology

    International Nuclear Information System (INIS)

    1995-10-01

    This book is about instrument on biochemistry and molecular biology, which consists of six chapters. It deals with introduction of advanced bio-instrument, common utilization and maintain, explanation of each instrument like capillary electrophoresis, interactive laser cytometer, personal computer and software, an electron microscope and DNA/RNS synthesis instrument, large equipment and special system like information system and network, analysis system for genome and large spectro graph, outside donation, examples for common utilization and appendix on data like application form for use.

  19. Borehole instrument for scintillation gamma spectrometer

    International Nuclear Information System (INIS)

    Sinitsyn, A.Ya.; Gabitov, R.M.

    1979-01-01

    Described are a schematic diagram and main specifications of a borehole instrument with autostabilization of energy scale measure by gamma bench-mark of 137 Cs, intended for the application in a logging gamma spectrometer to determine separately the concentrations of nature radioactive elements. The instrument may be connected to the KOBDFM-2 cable of 600 m length. It contains a scintillation counter for gamma quanta consisting of 30x70 mm NaI(Tl) crystal and a FEU-85 photoamplifier, an input conforming stage, a diagram of threshold pulse formation and regulating high-voltage generator. The borehole instrument has been proved under laboratory and field conditions at 10-40 deg C

  20. Research on Web-Based Networked Virtual Instrument System

    International Nuclear Information System (INIS)

    Tang, B P; Xu, C; He, Q Y; Lu, D

    2006-01-01

    The web-based networked virtual instrument (NVI) system is designed by using the object oriented methodology (OOM). The architecture of the NVI system consists of two major parts: client-web server interaction and instrument server-virtual instrument (VI) communication. The web server communicates with the instrument server and the clients connected to it over the Internet, and it handles identifying the user's name, managing the connection between the user and the instrument server, adding, removing and configuring VI's information. The instrument server handles setting the parameters of VI, confirming the condition of VI and saving the VI's condition information into the database. The NVI system is required to be a general-purpose measurement system that is easy to maintain, adapt and extend. Virtual instruments are connected to the instrument server and clients can remotely configure and operate these virtual instruments. An application of The NVI system is given in the end of the paper

  1. An intelligent instrument for measuring the dynamic parameters of groundwater

    International Nuclear Information System (INIS)

    Du Guoping

    2002-01-01

    An intelligent instrument was developed for measuring direction and velocity of the groundwater, permeability coefficient, hydraulic transmitting coefficient, static level, hydraulic gradient and flow direction of each layer. The instrument can be widely applied for detecting seepage of abutment and river bank, exploitation of groundwater, conservation of water and soil, water surging in mine, survey of groundwater resource and environment protection etc

  2. A Life in the Universe Survey

    Science.gov (United States)

    LoPresto, Michael C.; Hubble-Zdanowski, Jennifer

    2012-01-01

    The "Life in the Universe Survey" is a twelve-question assessment instrument. Largely based on the factors of the Drake equation, it is designed to survey students' initial estimates of its factors and to gauge how estimates change with instruction. The survey was used in sections of a seminar course focusing specifically on life in the universe…

  3. Instrumentation for PSD based neutron diffractometers at Dhruva reactor

    International Nuclear Information System (INIS)

    Pande, S.S.; Borkar, S.P.; Prafulla, S.; Srivastava, V.D.; Behare, A.; Mukhopadhyay, P.K.; Ghodgaonkar, M.D.; Kataria, S.K.

    2004-01-01

    Linear position sensitive detectors (PSDs) are widely used to configure neutron diffractometers and other instruments. Necessary front-end electronics and a data acquisition system is developed to cater to such instruments built around the Dhruva research reactor in BARC. These include three diffractometers with multiple PSDs and four with single PSD. The front-end electronics consists of high voltage units, preamplifiers, shaping amplifiers, ratio ADCs (RDC). The data acquisition system consists of an interface card and software. Commercially available hardware like temperature controller or stepper motor controller connected over GPIB or RS232 are also integrated in the data acquisition system. The data acquisition is automated so that it can continue unattended for control parameter like temperature, thus enabling optimum utilization of available beam time. The instrumentation is scalable and can be easily configured for various instrumental requirements. The front-end electronics and the data acquisition system are described here. (author)

  4. SHOCKED POSTSTARBUST GALAXY SURVEY. I. CANDIDATE POST-STARBUST GALAXIES WITH EMISSION LINE RATIOS CONSISTENT WITH SHOCKS

    Energy Technology Data Exchange (ETDEWEB)

    Alatalo, Katherine; Rich, Jeffrey A. [Observatories of the Carnegie Institution of Washington, 813 Santa Barbara Street, Pasadena, CA 91101 (United States); Cales, Sabrina L. [Yale Center for Astronomy and Astrophysics, Physics Department, Yale University, New Haven, CT 06511 (United States); Appleton, Philip N.; Lanz, Lauranne [Infrared Processing and Analysis Center, California Institute of Technology, Pasadena, CA 91125 (United States); Kewley, Lisa J.; Medling, Anne M. [Research School of Astronomy and Astrophysics, Australian National University, Cotter Road, Weston ACT 2611 (Australia); Lacy, Mark; Nyland, Kristina, E-mail: kalatalo@carnegiescience.edu [National Radio Astronomy Observatory, 520 Edgemont Road, Charlottesville, VA 22903 (United States)

    2016-06-01

    There are many mechanisms by which galaxies can transform from blue, star-forming spirals, to red, quiescent early-type galaxies, but our current census of them does not form a complete picture. Recent observations of nearby case studies have identified a population of galaxies that quench “quietly.” Traditional poststarburst searches seem to catch galaxies only after they have quenched and transformed, and thus miss any objects with additional ionization mechanisms exciting the remaining gas. The Shocked POststarburst Galaxy Survey (SPOGS) aims to identify transforming galaxies, in which the nebular lines are excited via shocks instead of through star formation processes. Utilizing the Oh-Sarzi-Schawinski-Yi (OSSY) measurements on the Sloan Digital Sky Survey Data Release 7 catalog, we applied Balmer absorption and shock boundary criteria to identify 1067 SPOG candidates (SPOGs*) within z = 0.2. SPOGs* represent 0.2% of the OSSY sample galaxies that exceed the continuum signal-to-noise cut (and 0.7% of the emission line galaxy sample). SPOGs* colors suggest that they are in an earlier phase of transition than OSSY galaxies that meet an “E+A” selection. SPOGs* have a 13% 1.4 GHz detection rate from the Faint Images of the Radio Sky at Twenty Centimeters Survey, higher than most other subsamples, and comparable only to low-ionization nuclear emission line region hosts, suggestive of the presence of active galactic nuclei (AGNs). SPOGs* also have stronger Na i D absorption than predicted from the stellar population, suggestive of cool gas being driven out in galactic winds. It appears that SPOGs* represent an earlier phase in galaxy transformation than traditionally selected poststarburst galaxies, and that a large proportion of SPOGs* also have properties consistent with disruption of their interstellar media, a key component to galaxy transformation. It is likely that many of the known pathways to transformation undergo a SPOG phase. Studying this sample of

  5. Neighborhood Disadvantage, Residential Stability, and Perceptions of Instrumental Support among New Mothers

    Science.gov (United States)

    Turney, Kristin; Harknett, Kristen

    2010-01-01

    Using longitudinal data from the Fragile Families and Child Wellbeing survey (N = 4,211), this study examines neighborhood disadvantage and perceptions of instrumental support among mothers with young children. The authors find that (a) living in a disadvantaged neighborhood is associated with less instrumental support, particularly financial…

  6. Return to sports after surgery to correct adolescent idiopathic scoliosis: a survey of the Spinal Deformity Study Group.

    Science.gov (United States)

    Lehman, Ronald A; Kang, Daniel G; Lenke, Lawrence G; Sucato, Daniel J; Bevevino, Adam J

    2015-05-01

    There are no guidelines for when surgeons should allow patients to return to sports and athletic activities after spinal fusion for adolescent idiopathic scoliosis (AIS). Current recommendations are based on anecdotal reports and a survey performed more than a decade ago in the era of first/second-generation posterior implants. To identify current recommendations for return to sports and athletic activities after surgery for AIS. Questionnaire-based survey. Adolescent idiopathic scoliosis after corrective surgery. Type and time to return to sports. A survey was administered to members of the Spinal Deformity Study Group. The survey consisted of surgeon demographic information, six clinical case scenarios, three different construct types (hooks, pedicle screws, hybrid), and questions regarding the influence of lowest instrumented vertebra (LIV) and postoperative physical therapy. Twenty-three surgeons completed the survey, and respondents were all experienced expert deformity surgeons. Pedicle screw instrumentation allows earlier return to noncontact and contact sports, with most patients allowed to return to running by 3 months, both noncontact and contact sports by 6 months, and collision sports by 12 months postoperatively. For all construct types, approximately 20% never allow return to collision sports, whereas all surgeons allow eventual return to contact and noncontact sports regardless of construct type. In addition to construct type, we found progressively distal LIV resulted in more surgeons never allowing return to collision sports, with 12% for selective thoracic fusion to T12/L1 versus 33% for posterior spinal fusion to L4. Most respondents also did not recommend formal postoperative physical therapy (78%). Of all surgeons surveyed, there was only one reported instrumentation failure/pullout without neurologic deficit after a patient went snowboarding 2 weeks postoperatively. Modern posterior instrumentation allows surgeons to recommend earlier return

  7. A method to automate the radiological survey process

    International Nuclear Information System (INIS)

    Berven, B.A.; Blair, M.S.

    1987-01-01

    This document describes the USRAD system, a hardware/software ranging and data transmission system, that provides real-time position data and combines it with other portable instrument measurements. Live display of position data and onsite data reduction, presentation, and formatting for reports and automatic transfer into databases are among the unusual attributes of USRADS. Approximately 25% of any survey-to-survey report process is dedicated to data recording and formatting, which is eliminated by USRADS. Cost savings are realized by the elimination of manual transcription of instrument readout in the field and clerical formatting of data in the office. Increased data reliability is realized by ensuring complete survey coverage of an area in the field, by elimination of mathematical errors in conversion of instrument readout to unit concentration, and by elimination of errors associated with transcribing data from the field into report format. The USRAD system can be adapted to measure other types of pollutants or physical/chemical/geological/biological conditions in which portable instrumentation exists. 2 refs., 2 figs

  8. User's guide for survey-meter- and film-badge-dosimetry data bases

    International Nuclear Information System (INIS)

    Phillips, W.G.; Sherman, S.; Young, R.

    1981-05-01

    This manual describes the data storage and retrieval system designed by Environmental Monitoring Systems Laboratory Las Vegas (EMSL-LV) for radiation exposure data recorded in offsite areas during and after nuclear weapons tests conducted at the Nevada Test Site in the 1950's and early 1960's. Referred to hereinafter as the EMSL-LV system, this system contains two distinct subsets of offsite radiological measurements collected during early nuclear atmospheric tests at the Nevada Test Site. The purpose of the manual is to present the methods for using the EMSL-LV system to examine all or any portion of either data subset. The two distinct subsets which comprise the EMSL-LV system are survey meter data and film badge dosimetry data. The survey meter data consist of readings obtained from portable radiation monitoring instruments used around the Nevada Test Site during the 1950's and early 1960's to measure radiation exposure rates resulting from the nuclear testing program. The dosimetry data consist of measurements of integrated radiation exposure made with film badge type dosimeters in areas surrounding the Nevada Test Site

  9. A measuring instrument for evaluation of quality systems.

    NARCIS (Netherlands)

    Wagner, C.; Bakker, D.H. de; Groenewegen, P.P.

    1999-01-01

    Objective: To develop an instrument for provider organizations, consumers, purchasers, and policy makers to measure and compare the development of quality systems in provider organizations. Design: Cross-sectional study of provider organizations using a structured questionnaire to survey managers.

  10. Validation of the National Institutes of Health Patient-Reported Outcomes Measurement Information System Survey as a Quality-of-Life Instrument for Patients with Malignant Brain Tumors and Their Caregivers.

    Science.gov (United States)

    Romero, Melissa M; Flood, Lisa Sue; Gasiewicz, Nanci K; Rovin, Richard; Conklin, Samantha

    2015-12-01

    At present there is a lack of well-validated surveys used to measure quality of life in patients with malignant brain tumors and their caregivers. The main objective of this pilot study was to validate the National Institutes of Health Patient-Reported Outcomes Measurement Information System (NIH PROMIS) survey for use as a quality-of-life measure in this population. This article presents the rationale for using the NIH PROMIS instrument as a quality-of-life measure for patients with malignant brain tumors and their caregivers. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Digital Education Governance: Data Visualization, Predictive Analytics, and "Real-Time" Policy Instruments

    Science.gov (United States)

    Williamson, Ben

    2016-01-01

    Educational institutions and governing practices are increasingly augmented with digital database technologies that function as new kinds of policy instruments. This article surveys and maps the landscape of digital policy instrumentation in education and provides two detailed case studies of new digital data systems. The Learning Curve is a…

  12. Translation and cross-cultural adaptation of the Brazilian Portuguese version of the Driving Behavior Survey (DBS

    Directory of Open Access Journals (Sweden)

    Jessye Almeida Cantini

    2013-12-01

    Full Text Available BACKGROUND: Fear of driving has been recognized as a complex diagnostic entity. For this reason, the use of psychometric instruments is fundamental to advancing research in this area. Psychometric instruments are also necessary for clinical care, as they can help conceptualize the disorder and plan adequate treatment. OBJECTIVE: To describe the cross-cultural adaptation of a Brazilian version of the Driving Behavior Survey (DBS. Methods: The process consisted of: 1 two translations and back-translations carried out by independent evaluators; 2 development of a brief version by four bilingual experts in mental health; 3 experimental application; and 4 investigation of operational equivalence. RESULTS: The adaptation process is described and a final Brazilian version of the DBS is presented. CONCLUSION: A new instrument is now available to assess the driving behaviors of the Brazilian population, facilitating research in this field.

  13. Rethinking Traditional Methods of Survey Validation

    Science.gov (United States)

    Maul, Andrew

    2017-01-01

    It is commonly believed that self-report, survey-based instruments can be used to measure a wide range of psychological attributes, such as self-control, growth mindsets, and grit. Increasingly, such instruments are being used not only for basic research but also for supporting decisions regarding educational policy and accountability. The…

  14. Reliability and concurrent validity of the Dutch hip and knee replacement expectations surveys.

    Science.gov (United States)

    van den Akker-Scheek, Inge; van Raay, Jos J A M; Reininga, Inge H F; Bulstra, Sjoerd K; Zijlstra, Wiebren; Stevens, Martin

    2010-10-19

    Preoperative expectations of outcome of total hip and knee arthroplasty are important determinants of patients' satisfaction and functional outcome. Aims of the study were (1) to translate the Hospital for Special Surgery Hip Replacement Expectations Survey and Knee Replacement Expectations Survey into Dutch and (2) to study test-retest reliability and concurrent validity. Patients scheduled for total hip (N = 112) or knee replacement (N = 101) were sent the Dutch Expectations Surveys twice with a 2 week interval to determine test-retest reliability. To determine concurrent validity, the Expectation WOMAC was sent. The results for the Dutch Hip Replacement Expectations Survey revealed good test-retest reliability (ICC 0.87), no bias and good internal consistency (alpha 0.86) (N = 72). The correlation between the Hip Expectations Score and the Expectation WOMAC score was 0.59 (N = 86). The results for the Dutch Knee Replacement Expectations Survey revealed good test-retest reliability (ICC 0.79), no bias and good internal consistency (alpha 0.91) (N = 46). The correlation with the Expectation WOMAC score was 0.52 (N = 57). Both Dutch Expectations Surveys are reliable instruments to determine patients' expectations before total hip or knee arthroplasty. As for concurrent validity, the correlation between both surveys and the Expectation WOMAC was moderate confirming that the same construct was determined. However, patients scored systematically lower on the Expectation WOMAC compared to the Dutch Expectation Surveys. Research on patients' expectations before total hip and knee replacement has only been performed in a limited amount of countries. With the Dutch Expectations Surveys it is now possible to determine patients' expectations in another culture and healthcare setting.

  15. Endotoxins in surgical instruments of hip arthroplasty

    Directory of Open Access Journals (Sweden)

    Vania Regina Goveia

    2016-06-01

    Full Text Available Abstract OBJECTIVE To investigate endotoxins in sterilized surgical instruments used in hip arthroplasties. METHOD A descriptive exploratory study conducted in a public teaching hospital. Six types of surgical instruments were selected, namely: acetabulum rasp, femoral rasp, femoral head remover, chisel box, flexible bone reamer and femoral head test. The selection was based on the analysis of the difficulty in removing bone and blood residues during cleaning. The sample was made up of 60 surgical instruments, which were tested for endotoxins in three different stages. The EndosafeTM Gel-Clot LAL (Limulus Amebocyte Lysate method was used. RESULT There was consistent gel formation with positive analysis in eight instruments, corresponding to 13.3%, being four femoral rasps and four bone reamers. CONCLUSION Endotoxins in quantity ≥0.125 UE/mL were detected in 13.3% of the instruments tested.

  16. Survey of instrumentation used for monitoring metals in water

    Energy Technology Data Exchange (ETDEWEB)

    Quinby-Hunt, M.S.

    1978-06-01

    A study was conducted of instrumentation used to determine metals in water. Several of the techniques most commonly used for analysis and routine determinations of metals in water are shown in Table 1. They are atomic absorption spectroscopy, both flame and flameless, atomic emission spectroscopy using conventional flame sources and inductively-coupled plasma sources, and ultraviolet-visible absorption techniques. Other less frequently employed methods are x-ray fluorescence analysis using both photon and charged particle excitation with energy-dispersive and wavelength-dispersive spectral analysis. Also electrochemical techniques and activation analysis are studied.

  17. Instrumentation for PSD-based neutron diffractometers at Dhruva reactor

    Science.gov (United States)

    Pande, S. S.; Borkar, S. P.; Prafulla, S.; Srivastava, V. D.; Behare, A.; Mukhopadhyay, P. K.; Ghodgaonkar, M. D.; Kataria, S. K.

    2004-08-01

    Linear position sensitive detectors (PSDs) are widely used to configure neutron diffractometers and other instruments. Necessary front-end electronics and a data acquisition system [1] is developed to cater to such instruments built around the Dhruva research reactor in BARC. These include three diffractometers with multiple PSDs and four with single PSD. The front-end electronics consists of high voltage units, preamplifiers [2], shaping amplifiers, ratio ADCs (RDC) [3]. The data acquisition system consists of an interface card and software. Commercially available hardware like temperature controller or stepper motor controller connected over GPIB or RS232 are also integrated in the data acquisition system. The data acquisition is automated so that it can continue unattended for control parameter like temperature, thus enabling optimum utilization of available beam time. The instrumentation is scalable and can be easily configured for various instrumental requirements. The front-end electronics and the data acquisition system are described here.

  18. Normalization of energy-dependent gamma survey data.

    Science.gov (United States)

    Whicker, Randy; Chambers, Douglas

    2015-05-01

    Instruments and methods for normalization of energy-dependent gamma radiation survey data to a less energy-dependent basis of measurement are evaluated based on relevant field data collected at 15 different sites across the western United States along with a site in Mongolia. Normalization performance is assessed relative to measurements with a high-pressure ionization chamber (HPIC) due to its "flat" energy response and accurate measurement of the true exposure rate from both cosmic and terrestrial radiation. While analytically ideal for normalization applications, cost and practicality disadvantages have increased demand for alternatives to the HPIC. Regression analysis on paired measurements between energy-dependent sodium iodide (NaI) scintillation detectors (5-cm by 5-cm crystal dimensions) and the HPIC revealed highly consistent relationships among sites not previously impacted by radiological contamination (natural sites). A resulting generalized data normalization factor based on the average sensitivity of NaI detectors to naturally occurring terrestrial radiation (0.56 nGy hHPIC per nGy hNaI), combined with the calculated site-specific estimate of cosmic radiation, produced reasonably accurate predictions of HPIC readings at natural sites. Normalization against two to potential alternative instruments (a tissue-equivalent plastic scintillator and energy-compensated NaI detector) did not perform better than the sensitivity adjustment approach at natural sites. Each approach produced unreliable estimates of HPIC readings at radiologically impacted sites, though normalization against the plastic scintillator or energy-compensated NaI detector can address incompatibilities between different energy-dependent instruments with respect to estimation of soil radionuclide levels. The appropriate data normalization method depends on the nature of the site, expected duration of the project, survey objectives, and considerations of cost and practicality.

  19. Developing, testing, and implementing a survey of scientist mentoring teachers as part of an RET: The GABI RET mentor survey.

    Science.gov (United States)

    Davey, B.

    2017-12-01

    The impacts of mentoring in education have been well established. Mentors have a large impact on their mentees and have been show to affect mentee attitudes towards learning, interest in subjects, future success, and more. While mentoring has a well-documented impact on the mentees, mentoring also has an impact on the mentors themselves. However, little has been studied empirically about these impacts. When we looked for a validated instrument that measured the impact of mentoring on the scientists working with the teachers, we found many anecdotal reports but no instruments that meet our specific needs. To this end, we developed, tested, and implemented our own instrument for measuring the impacts of mentoring on our scientist mentors. Our instrument contained both quantitative and qualitative items designed to reveal the effects of mentoring in two areas: 1) cognitive domain (mentoring, teaching, understanding K-12) and 2) affective domain (professional, personal, participation). We first shared our survey with experts in survey development and mentoring, gathered their feedback, and incorporated their suggestions into our instrument. We then had a subsection of our mentors complete the survey and then complete it again three to four days later (test-retest). Our survey has a high correlation for the test-retest quantitative items (0.93) and a high correlation (0.90) between the three reviewers of the qualitative items. From our findings, we feel we have a validated instrument (face, content, and contruct validity) that answers our research questions reliably. Our contribution to the study of mentoring of science teachers reveals a broad range of impacts on the mentors themselves including an improved understanding of the challenges of classroom teaching, a recognition of the importance of scientists working with science teachers, an enhanced ability to communicate their research and findings, and an increased interest and excitement for their own work.

  20. Determinants of National Health Insurance enrolment in Ghana across the life course: Are the results consistent between surveys?

    Science.gov (United States)

    van der Wielen, Nele; Falkingham, Jane; Channon, Andrew Amos

    2018-04-23

    Ghana is currently undergoing a profound demographic transition, with large increases in the number of older adults in the population. Older adults require greater levels of healthcare as illness and disability increase with age. Ghana therefore provides an important and timely case study of policy implementation aimed at improving equal access to healthcare in the context of population ageing. This paper examines the determinants of National Health Insurance (NHIS) enrolment in Ghana, using two different surveys and distinguishing between younger and older adults. Two surveys are used in order to investigate consistency in insurance enrolment. The comparison between age groups is aimed at understanding whether determinants differ for older adults. Previous studies have mainly focused on the enrolment of young and middle aged adults; thus by widening the focus to include older adults and taking into account differences in their demographic and socio-economic characteristics this paper provides a unique contribution to the literature. Using data from the 2007-2008 Study on Global Ageing and Adult Health (SAGE) and the 2012-2013 Ghanaian Living Standards Survey (GLSS) the determinants of NHIS enrolment among younger adults (aged 18-49) and older adults (aged 50 and over) are compared. Logistic regression explores the socio-economic and demographic determinants of NHIS enrolment and multinomial logistic regression investigates the correlates of insurance drop out. Similar results for people aged 18-49 and people aged 50 plus were revealed, with older adults having a slightly lower probability of dropping out of insurance coverage compared to younger adults. Both surveys confirm that education and wealth increase the likelihood of NHIS affiliation. Further, residential differences in insurance coverage are found, with greater NHIS coverage in urban areas. The findings give assurance that both datasets (SAGE and GLSS) are suitable for research on insurance affiliation

  1. On-line instrument for control of water and steam quality at energy production plants - a market survey

    International Nuclear Information System (INIS)

    Fahlgren, N.; Persson, F.

    1988-10-01

    Instruments for on-line measuring are today available for all water analyses that can be of intrerest in power stations. For some of the analyses instruments have been in operation for many years e.g. for determination of silica, sodium and oxygen. For other analyses no instruments or only a few have been in operation. Many instruments are developed under the last years. Operation experiences for many instruments are therefore limited. For mostly all instruments, also for instruments that have been in operation a long time, operation experiences from the same type of instruments differ from plant to plant. The reson is that most of the instruments need daily or weekly maintenance and that has not always been aquainted. The time for necessary maintenance is however not so long that it is deterrent. The time for necessary maintenance for an instrument is normally 1-2 hours a week. On-line measuring, improve supervision and reliability of service and are therefore to recommend in both big and small plants. In small plants it is very important to have a good supervision of pH-value, conductivity, harness and the content of oxygen in feed water. (authors)

  2. Trends in instrumentation for environmental radiation measurements at Los Alamos Scientific Laboratory

    International Nuclear Information System (INIS)

    Hiebert, R.D.; Wolf, M.A.

    1980-01-01

    Recent instruments developed to fulfill radiation monitoring needs at Los Alamos Scientific Laboratory are described. Laboratory instruments that measure tritium gas effluents alone, or in the presence of activated air from D-T fusion reactors are discussed. Fully portable systems for gamma, x-ray, and alpha analyses in the field are described. Also included are descriptions of survey instruments that measure low levels of transuranic contaminants and that measure pulsed-neutron dose rates

  3. The Development of Precise Engineering Surveying Technology

    Directory of Open Access Journals (Sweden)

    LI Guangyun

    2017-10-01

    Full Text Available With the construction of big science projects in China, the precise engineering surveying technology developed rapidly in the 21th century. Firstly, the paper summarized up the current development situation for the precise engineering surveying instrument and theory. Then the three typical cases of the precise engineering surveying practice such as accelerator alignment, industry measurement and high-speed railway surveying technology are focused.

  4. NEW INSTRUMENTS FOR SURVEY: ON LINE SOFTWARES FOR 3D RECONTRUCTION FROM IMAGES

    Directory of Open Access Journals (Sweden)

    E. Fratus de Balestrini

    2012-09-01

    Full Text Available 3d scanning technologies had a significant development and have been widely used in documentation of cultural, architectural and archeological heritages. Modern methods of three-dimensional acquiring and modeling allow to represent an object through a digital model that combines visual potentialities of images (normally used for documentation to the accuracy of the survey, becoming at the same time support for the visualization that for metric evaluation of any artefact that have an historical or artistic interest, opening up new possibilities for cultural heritage's fruition, cataloging and study. Despite this development, because of the small catchment area and the 3D laser scanner's sophisticated technologies, the cost of these instruments is very high and beyond the reach of most operators in the field of cultural heritages. This is the reason why they have appeared low-cost technologies or even free, allowing anyone to approach the issues of acquisition and 3D modeling, providing tools that allow to create three-dimensional models in a simple and economical way. The research, conducted by the Laboratory of Photogrammetry of the University IUAV of Venice, of which we present here some results, is intended to figure out whether, with Arc3D, it is possible to obtain results that can be somehow comparable, in therms of overall quality, to those of the laser scanner, and/or whether it is possible to integrate them. They were carried out a series of tests on certain types of objects, models made with Arc3D, from raster images, were compared with those obtained using the point clouds from laser scanner. We have also analyzed the conditions for an optimal use of Arc3D: environmental conditions (lighting, acquisition tools (digital cameras and type and size of objects. After performing the tests described above, we analyzed the patterns generated by Arc3D to check what other graphic representations can be obtained from them: orthophotos and drawings

  5. Considerations in comparing the U.S. Geological Survey one‐year induced‐seismicity hazard models with “Did You Feel It?” and instrumental data

    Science.gov (United States)

    White, Isabel; Liu, Taojun; Luco, Nicolas; Liel, Abbie

    2017-01-01

    The recent steep increase in seismicity rates in Oklahoma, southern Kansas, and other parts of the central United States led the U.S. Geological Survey (USGS) to develop, for the first time, a probabilistic seismic hazard forecast for one year (2016) that incorporates induced seismicity. In this study, we explore a process to ground‐truth the hazard model by comparing it with two databases of observations: modified Mercalli intensity (MMI) data from the “Did You Feel It?” (DYFI) system and peak ground acceleration (PGA) values from instrumental data. Because the 2016 hazard model was heavily based on earthquake catalogs from 2014 to 2015, this initial comparison utilized observations from these years. Annualized exceedance rates were calculated with the DYFI and instrumental data for direct comparison with the model. These comparisons required assessment of the options for converting hazard model results and instrumental data from PGA to MMI for comparison with the DYFI data. In addition, to account for known differences that affect the comparisons, the instrumental PGA and DYFI data were declustered, and the hazard model was adjusted for local site conditions. With these adjustments, examples at sites with the most data show reasonable agreement in the exceedance rates. However, the comparisons were complicated by the spatial and temporal completeness of the instrumental and DYFI observations. Furthermore, most of the DYFI responses are in the MMI II–IV range, whereas the hazard model is oriented toward forecasts at higher ground‐motion intensities, usually above about MMI IV. Nevertheless, the study demonstrates some of the issues that arise in making these comparisons, thereby informing future efforts to ground‐truth and improve hazard modeling for induced‐seismicity applications.

  6. ProtoDESI: First On-Sky Technology Demonstration for the Dark Energy Spectroscopic Instrument

    Science.gov (United States)

    Fagrelius, Parker; Abareshi, Behzad; Allen, Lori; Ballester, Otger; Baltay, Charles; Besuner, Robert; Buckley-Geer, Elizabeth; Butler, Karen; Cardiel, Laia; Dey, Arjun; Duan, Yutong; Elliott, Ann; Emmet, William; Gershkovich, Irena; Honscheid, Klaus; Illa, Jose M.; Jimenez, Jorge; Joyce, Richard; Karcher, Armin; Kent, Stephen; Lambert, Andrew; Lampton, Michael; Levi, Michael; Manser, Christopher; Marshall, Robert; Martini, Paul; Paat, Anthony; Probst, Ronald; Rabinowitz, David; Reil, Kevin; Robertson, Amy; Rockosi, Connie; Schlegel, David; Schubnell, Michael; Serrano, Santiago; Silber, Joseph; Soto, Christian; Sprayberry, David; Summers, David; Tarlé, Greg; Weaver, Benjamin A.

    2018-02-01

    The Dark Energy Spectroscopic Instrument (DESI) is under construction to measure the expansion history of the universe using the baryon acoustic oscillations technique. The spectra of 35 million galaxies and quasars over 14,000 square degrees will be measured during a 5-year survey. A new prime focus corrector for the Mayall telescope at Kitt Peak National Observatory will deliver light to 5,000 individually targeted fiber-fed robotic positioners. The fibers in turn feed ten broadband multi-object spectrographs. We describe the ProtoDESI experiment, that was installed and commissioned on the 4-m Mayall telescope from 2016 August 14 to September 30. ProtoDESI was an on-sky technology demonstration with the goal to reduce technical risks associated with aligning optical fibers with targets using robotic fiber positioners and maintaining the stability required to operate DESI. The ProtoDESI prime focus instrument, consisting of three fiber positioners, illuminated fiducials, and a guide camera, was installed behind the existing Mosaic corrector on the Mayall telescope. A fiber view camera was mounted in the Cassegrain cage of the telescope and provided feedback metrology for positioning the fibers. ProtoDESI also provided a platform for early integration of hardware with the DESI Instrument Control System that controls the subsystems, provides communication with the Telescope Control System, and collects instrument telemetry data. Lacking a spectrograph, ProtoDESI monitored the output of the fibers using a fiber photometry camera mounted on the prime focus instrument. ProtoDESI was successful in acquiring targets with the robotically positioned fibers and demonstrated that the DESI guiding requirements can be met.

  7. Backscattering at a pulsed neutron source, the MUSICAL instrument

    International Nuclear Information System (INIS)

    Alefeld, B.

    1995-01-01

    In the first part the principles of the neutron backscattering method are described and some simple considerations about the energy resolution and the intensity are presented. A prototype of a backscattering instrument, the first Juelich instrument, is explained in some detail and a representative measurement is shown which was performed on the backscattering instrument IN10 at the ILL in Grenoble. In the second part a backscattering instrument designed for a pulsed neutron source is proposed. It is shown that a rather simple modification, which consists in the replacement of the Doppler drive of the conventional backscattering instrument by a multi silicon monochromator crystal (MUSICAL) leads to a very effective instrument, benefitting from the peak flux of the pulsed source. ((orig.))

  8. The Development of a Tactical-Level Full Range Leadership Measurement Instrument

    Science.gov (United States)

    2010-03-01

    full range leadership theory has become established as the predominant and most widely researched theory on leadership . The most commonly used survey...instrument to assess full range leadership theory is the Multifactor Leadership Questionnaire, originally developed by Bass in 1985. Although much...existing literature to develop a new full range leadership theory measurement instrument that effectively targets low- to mid-level supervisors, or

  9. OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. III. MEASURES BELOW THE DIFFRACTION LIMIT OF THE WIYN TELESCOPE

    International Nuclear Information System (INIS)

    Horch, Elliott P.; Van Altena, William F.; Howell, Steve B.; Sherry, William H.; Ciardi, David R.

    2011-01-01

    In this paper, we study the ability of CCD- and electron-multiplying-CCD-based speckle imaging to obtain reliable astrometry and photometry of binary stars below the diffraction limit of the WIYN 3.5 m Telescope. We present a total of 120 measures of binary stars, 75 of which are below the diffraction limit. The measures are divided into two groups that have different measurement accuracy and precision. The first group is composed of standard speckle observations, that is, a sequence of speckle images taken in a single filter, while the second group consists of paired observations where the two observations are taken on the same observing run and in different filters. The more recent paired observations were taken simultaneously with the Differential Speckle Survey Instrument, which is a two-channel speckle imaging system. In comparing our results to the ephemeris positions of binaries with known orbits, we find that paired observations provide the opportunity to identify cases of systematic error in separation below the diffraction limit and after removing these from consideration, we obtain a linear measurement uncertainty of 3-4 mas. However, if observations are unpaired or if two observations taken in the same filter are paired, it becomes harder to identify cases of systematic error, presumably because the largest source of this error is residual atmospheric dispersion, which is color dependent. When observations are unpaired, we find that it is unwise to report separations below approximately 20 mas, as these are most susceptible to this effect. Using the final results obtained, we are able to update two older orbits in the literature and present preliminary orbits for three systems that were discovered by Hipparcos.

  10. High-performance instruments in neutron arena of JHP. Preliminary version

    International Nuclear Information System (INIS)

    Furusaka, M.; Itoh, S.; Otomo, T.; Arai, M.

    1996-05-01

    This report is a preliminary report of high-performance instruments in neutron arena of JHP (Japan Hadron Project). This report consists of as follows; neutron intensity of neutron arena, development of neutron sources in neutron arena, experimental devices and instrumentation. (J.P.N.)

  11. Towards the development of an outcome instrument for spinal trauma: an international survey of spinal surgeons.

    Science.gov (United States)

    Oner, F Cumhur; Sadiqi, Said; Lehr, A Mechteld; Dvorak, Marcel F; Aarabi, Bizhan; Chapman, Jens R; Fehlings, Michael G; Kandziora, Frank; Rajasekaran, S; Vaccaro, Alexander R

    2015-01-15

    International web-based survey. To identify the most relevant aspects of human function and health status from the perspective of health care professionals involved in the treatment of spinal trauma patients. There is no universally accepted outcome instrument available that is specifically designed or validated for spinal trauma patients, contributing to controversies related to the optimal treatment and evaluation of many types of spinal injuries. Therefore, the AOSpine Knowledge Forum Trauma aims to develop such an instrument using the International Classification of Functioning, Disability, and Health (ICF) as its basis. Experts from the 5 AOSpine International world regions were asked to give their opinion on the relevance of a compilation of 143 ICF categories for spinal trauma patients on a 3-point scale: "not relevant," "probably relevant," or "definitely relevant." The responses were analyzed using frequency analysis. Possible differences in responses between the 5 world regions were analyzed with the Fisher exact test and descriptive statistics. Of the 895 invited AOSpine International members, 150 (16.8%) participated in this study. A total of 13 (9.1%) ICF categories were identified as definitely relevant by more than 80% of the participants. Most of these categories were related to the ICF component "activities and participation" (n = 8), followed by "body functions" (n = 4), and "body structures" (n = 1). Only some minor regional differences were observed in the pattern of answers. More than 80% of an international group of health care professionals experienced in the clinical care of adult spinal trauma patients indicated 13 of 143 ICF categories as definitely relevant to measure outcomes after spinal trauma. This study creates an evidence base to define a core set of ICF categories for outcome measurement in adult spinal trauma patients.

  12. A positioning and data logging system for surface geophysical surveys

    International Nuclear Information System (INIS)

    Nyquist, J.E.; Blair, M.S.

    1988-01-01

    The Ultrasonic Ranging and Data System (USRADS) developed at ORNL is being adapted to work with two commercially available geophysical instruments: a magnetometer and an EM31 terrain conductivity meter. Geophysical surveys have proven an important preliminary step in investigating hazardous waste sites. Magnetometers and terrain conductivity meters are used to locate buried drums, trenches, conductive contaminant plumes and map regional changes in geology. About half the field time of a typical geophysical investigation is spent surveying the position of the grid points at which the measurements will be made. Additional time is lost and errors may be made recording instrument values in field notebooks and transcribing the data to a computer. Developed for gamma radiation surveys, the USRAD system keeps track of the surveyor's position automatically by triangulating on an ultrasonic transmitter carried in a backpack. The backpack also contains a radio transmitter that sends the instrument's reading coincident with the ultrasonic pulse. The surveyor's position and the instrument's reading are recorded by a portable computer which can plot the data to check the survey's progress. Electronic files are stored in a form compatible with AutoCAD to speed report writing. 7 refs., 3 figs

  13. Optimising the effect of policy instruments

    DEFF Research Database (Denmark)

    Pedersen, Anders Branth; Nielsen, Helle Ørsted; Christensen, Tove

    2012-01-01

    Economic modelling generally assumes that businesses are profit maximisers. However, behavioural economics holds that businesses pursue multiple objectives and may even sacrifice some profit. This has implications for the effectiveness of incentive-based environmental policies. Using Danish farme...... to policy instruments; farmers who focus on yield indicate less responsiveness to economic policy instruments. The results imply that it is important to implement a broad array of policy instruments to match different farmer rationales.......Economic modelling generally assumes that businesses are profit maximisers. However, behavioural economics holds that businesses pursue multiple objectives and may even sacrifice some profit. This has implications for the effectiveness of incentive-based environmental policies. Using Danish farmers...... as a case, this paper examines whether non-economic rationales may trump economic ones in farmer decisions, and, unlike previous research, we quantify how widespread non-economic values are compared to more economic values. Data derive from a survey (1164 responses) of Danish conventional farmers' decision...

  14. A New Automated Instrument Calibration Facility at the Savannah River Site

    International Nuclear Information System (INIS)

    Polz, E.; Rushton, R.O.; Wilkie, W.H.; Hancock, R.C.

    1998-01-01

    The Health Physics Instrument Calibration Facility at the Savannah River Site in Aiken, SC was expressly designed and built to calibrate portable radiation survey instruments. The facility incorporates recent advances in automation technology, building layout and construction, and computer software to improve the calibration process. Nine new calibration systems automate instrument calibration and data collection. The building is laid out so that instruments are moved from one area to another in a logical, efficient manner. New software and hardware integrate all functions such as shipping/receiving, work flow, calibration, testing, and report generation. Benefits include a streamlined and integrated program, improved efficiency, reduced errors, and better accuracy

  15. Polyphonic pitch detection and instrument separation

    Science.gov (United States)

    Bay, Mert; Beauchamp, James W.

    2005-09-01

    An algorithm for polyphonic pitch detection and musical instrument separation is presented. Each instrument is represented as a time-varying harmonic series. Spectral information is obtained from a monaural input signal using a spectral peak tracking method. Fundamental frequencies (F0s) for each time frame are estimated from the spectral data using an Expectation Maximization (EM) algorithm with a Gaussian mixture model representing the harmonic series. The method first estimates the most predominant F0, suppresses its series in the input, and then the EM algorithm is run iteratively to estimate each next F0. Collisions between instrument harmonics, which frequently occur, are predicted from the estimated F0s, and the resulting corrupted harmonics are ignored. The amplitudes of these corrupted harmonics are replaced by harmonics taken from a library of spectral envelopes for different instruments, where the spectrum which most closely matches the important characteristics of each extracted spectrum is chosen. Finally, each voice is separately resynthesized by additive synthesis. This algorithm is demonstrated for a trio piece that consists of 3 different instruments.

  16. Victimisation surveys: What are they good for?

    Directory of Open Access Journals (Sweden)

    Aromaa Kauko

    2012-01-01

    Full Text Available The author analyzes the usefulness of victimization surveys. The paper is focused of surveys in which nationally representative population samples are surveyed for their personal victimisation experiences, and their attitudes and opinions of issues related to crime and crime control. The author points out the benefits of using victimization surveys, but also explains why most countries have failed to make systematic use of this instrument.

  17. THE SPITZER DEEP, WIDE-FIELD SURVEY

    International Nuclear Information System (INIS)

    Ashby, M. L. N.; Brodwin, M.; Stern, D.; Griffith, R.; Eisenhardt, P.; Gorjian, V.; Kozlowski, S.; Kochanek, C. S.; Bock, J. J.; Borys, C.; Brand, K.; Grogin, N. A.; Brown, M. J. I.; Cool, R.; Cooray, A.; Croft, S.; Dey, A.; Eisenstein, D.; Gonzalez, A. H.; Ivison, R. J.

    2009-01-01

    The Spitzer Deep, Wide-Field Survey (SDWFS) is a four-epoch infrared survey of 10 deg. 2 in the Booetes field of the NOAO Deep Wide-Field Survey using the IRAC instrument on the Spitzer Space Telescope. SDWFS, a Spitzer Cycle 4 Legacy project, occupies a unique position in the area-depth survey space defined by other Spitzer surveys. The four epochs that make up SDWFS permit-for the first time-the selection of infrared-variable and high proper motion objects over a wide field on timescales of years. Because of its large survey volume, SDWFS is sensitive to galaxies out to z ∼ 3 with relatively little impact from cosmic variance for all but the richest systems. The SDWFS data sets will thus be especially useful for characterizing galaxy evolution beyond z ∼ 1.5. This paper explains the SDWFS observing strategy and data processing, presents the SDWFS mosaics and source catalogs, and discusses some early scientific findings. The publicly released, full-depth catalogs contain 6.78, 5.23, 1.20, and 0.96 x 10 5 distinct sources detected to the average 5σ, 4''-diameter, aperture-corrected limits of 19.77, 18.83, 16.50, and 15.82 Vega mag at 3.6, 4.5, 5.8, and 8.0 μm, respectively. The SDWFS number counts and color-color distribution are consistent with other, earlier Spitzer surveys. At the 6 minute integration time of the SDWFS IRAC imaging, >50% of isolated Faint Images of the Radio Sky at Twenty cm radio sources and >80% of on-axis XBooetes sources are detected out to 8.0 μm. Finally, we present the four highest proper motion IRAC-selected sources identified from the multi-epoch imaging, two of which are likely field brown dwarfs of mid-T spectral class.

  18. Pilot information needs survey regarding climate relevant technologies

    International Nuclear Information System (INIS)

    Van Berkel, R.; Van Roekel, A.

    1997-02-01

    The objective of this pilot survey was to arrive at a preliminary understanding of the initial technology and technology information needs in non-Annex II countries in order to support international efforts to facilitate the transfer of technologies and know-how conducive to mitigating and adapting to climate change. The study encompassed two main components, i.e. the development of a survey instrument and the execution of a pilot survey among selected non-Annex II countries. The survey instrument addresses the present status of enabling activities; technology and technology information needs; and issues related to information supply and accessibility. The survey was distributed to national focal points in 20 non-Annex II countries and to at least 35 other stakeholders in five of these non-Annex II countries. A total of 27 completed questionnaires were received, covering 10 non-Annex II countries. 3 refs

  19. Pilot information needs survey regarding climate relevant technologies

    Energy Technology Data Exchange (ETDEWEB)

    Van Berkel, R.; Van Roekel, A.

    1997-02-01

    The objective of this pilot survey was to arrive at a preliminary understanding of the initial technology and technology information needs in non-Annex II countries in order to support international efforts to facilitate the transfer of technologies and know-how conducive to mitigating and adapting to climate change. The study encompassed two main components, i.e. the development of a survey instrument and the execution of a pilot survey among selected non-Annex II countries. The survey instrument addresses the present status of enabling activities; technology and technology information needs; and issues related to information supply and accessibility. The survey was distributed to national focal points in 20 non-Annex II countries and to at least 35 other stakeholders in five of these non-Annex II countries. A total of 27 completed questionnaires were received, covering 10 non-Annex II countries. 3 refs.

  20. The positive mental health instrument: development and validation of a culturally relevant scale in a multi-ethnic asian population

    Directory of Open Access Journals (Sweden)

    Vaingankar Janhavi

    2011-10-01

    Full Text Available Abstract Background Instruments to measure mental health and well-being are largely developed and often used within Western populations and this compromises their validity in other cultures. A previous qualitative study in Singapore demonstrated the relevance of spiritual and religious practices to mental health, a dimension currently not included in exiting multi-dimensional measures. The objective of this study was to develop a self-administered measure that covers all key and culturally appropriate domains of mental health, which can be applied to compare levels of mental health across different age, gender and ethnic groups. We present the item reduction and validation of the Positive Mental Health (PMH instrument in a community-based adult sample in Singapore. Methods Surveys were conducted among adult (21-65 years residents belonging to Chinese, Malay and Indian ethnicities. Exploratory and confirmatory factor analysis (EFA, CFA were conducted and items were reduced using item response theory tests (IRT. The final version of the PMH instrument was tested for internal consistency and criterion validity. Items were tested for differential item functioning (DIF to check if items functioned in the same way across all subgroups. Results: EFA and CFA identified six first-order factor structure (General coping, Personal growth and autonomy, Spirituality, Interpersonal skills, Emotional support, and Global affect under one higher-order dimension of Positive Mental Health (RMSEA = 0.05, CFI = 0.96, TLI = 0.96. A 47-item self-administered multi-dimensional instrument with a six-point Likert response scale was constructed. The slope estimates and strength of the relation to the theta for all items in each six PMH subscales were high (range:1.39 to 5.69, suggesting good discrimination properties. The threshold estimates for the instrument ranged from -3.45 to 1.61 indicating that the instrument covers entire spectrums for the six dimensions. The

  1. Consistent Valuation across Curves Using Pricing Kernels

    Directory of Open Access Journals (Sweden)

    Andrea Macrina

    2018-03-01

    Full Text Available The general problem of asset pricing when the discount rate differs from the rate at which an asset’s cash flows accrue is considered. A pricing kernel framework is used to model an economy that is segmented into distinct markets, each identified by a yield curve having its own market, credit and liquidity risk characteristics. The proposed framework precludes arbitrage within each market, while the definition of a curve-conversion factor process links all markets in a consistent arbitrage-free manner. A pricing formula is then derived, referred to as the across-curve pricing formula, which enables consistent valuation and hedging of financial instruments across curves (and markets. As a natural application, a consistent multi-curve framework is formulated for emerging and developed inter-bank swap markets, which highlights an important dual feature of the curve-conversion factor process. Given this multi-curve framework, existing multi-curve approaches based on HJM and rational pricing kernel models are recovered, reviewed and generalised and single-curve models extended. In another application, inflation-linked, currency-based and fixed-income hybrid securities are shown to be consistently valued using the across-curve valuation method.

  2. Corporate Entrepreneurship Assessment Instrument (CEAI): Refinement and Validation of a Survey Measure

    National Research Council Canada - National Science Library

    Cates, Michael S

    2007-01-01

    .... The measurement instrument known as the Corporate Entrepreneurship Assessment Index (CEAI) has been designed to tap the climate-related organizational factors that represent and potentially encourage corporate entrepreneurship...

  3. Impact of Alzheimer's Disease on Caregiver Questionnaire: internal consistency, convergent validity, and test-retest reliability of a new measure for assessing caregiver burden.

    Science.gov (United States)

    Cole, Jason C; Ito, Diane; Chen, Yaozhu J; Cheng, Rebecca; Bolognese, Jennifer; Li-McLeod, Josephine

    2014-09-04

    There is a lack of validated instruments to measure the level of burden of Alzheimer's disease (AD) on caregivers. The Impact of Alzheimer's Disease on Caregiver Questionnaire (IADCQ) is a 12-item instrument with a seven-day recall period that measures AD caregiver's burden across emotional, physical, social, financial, sleep, and time aspects. Primary objectives of this study were to evaluate psychometric properties of IADCQ administered on the Web and to determine most appropriate scoring algorithm. A national sample of 200 unpaid AD caregivers participated in this study by completing the Web-based version of IADCQ and Short Form-12 Health Survey Version 2 (SF-12v2™). The SF-12v2 was used to measure convergent validity of IADCQ scores and to provide an understanding of the overall health-related quality of life of sampled AD caregivers. The IADCQ survey was also completed four weeks later by a randomly selected subgroup of 50 participants to assess test-retest reliability. Confirmatory factor analysis (CFA) was implemented to test the dimensionality of the IADCQ items. Classical item-level and scale-level psychometric analyses were conducted to estimate psychometric characteristics of the instrument. Test-retest reliability was performed to evaluate the instrument's stability and consistency over time. Virtually none (2%) of the respondents had either floor or ceiling effects, indicating the IADCQ covers an ideal range of burden. A single-factor model obtained appropriate goodness of fit and provided evidence that a simple sum score of the 12 items of IADCQ can be used to measure AD caregiver's burden. Scales-level reliability was supported with a coefficient alpha of 0.93 and an intra-class correlation coefficient (for test-retest reliability) of 0.68 (95% CI: 0.50-0.80). Low-moderate negative correlations were observed between the IADCQ and scales of the SF-12v2. The study findings suggest the IADCQ has appropriate psychometric characteristics as a

  4. Critical review of directional neutron survey meters

    Science.gov (United States)

    Balmer, Matthew J. I.; Gamage, Kelum A. A.; Taylor, Graeme C.

    2014-01-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument.

  5. Critical Review of Directional Neutron Survey Meters

    International Nuclear Information System (INIS)

    Balmer, M.J.I.; Gamage, K.A.A.; Taylor, G.C.

    2013-06-01

    Having been overlooked for many years, research is now starting to take into account the directional distribution of the neutron work place field. The impact of not taking this into account has led to overly conservative estimates of dose in neutron workplace fields. This paper provides a critical review of this existing research into directional survey meters which could improve these estimates of dose. Instruments which could be adapted for use as directional neutron survey meters are also considered within this review. Using Monte-Carlo techniques, two of the most promising existing designs are evaluated; a boron-doped liquid scintillator and a multi-detector directional spectrometer. As an outcome of these simulations, possible adaptations to these instruments are suggested with a view to improving the portability of the instrument. (authors)

  6. The Complexity integrated-Instruments components media of IPA at Elementary School

    Directory of Open Access Journals (Sweden)

    Angreni Siska

    2018-01-01

    Full Text Available This research aims at describing the complexity of Integrated Instrument Components media (CII in learning of science at Elementary schools in District Siulak Mukai and at Elementary schools in District Siulak. The research applied a descriptive method which included survey forms. Instruments used were observation sheets. The result of the research showed Integrated Instrument Components media (CII natural science that complexity at primary school district Siulak was more complex compared with that at primary school district Siulak Mukai. is better than from primary school district Mukai

  7. Consistency vs. Diversity in Tournament Events: A Survey of Coaches and Competitors.

    Science.gov (United States)

    Manchester, Bruce B.; Friedley, Sheryl A.

    Noting the diversity in the nature and format of individual events in debate tournaments, a study surveyed the reactions of individual events coaches and students to the events offered at tournaments, the descriptions, and the time limits. Thirty-one coaches and 71 students from colleges and universities in the eastern United States responded to a…

  8. Design and development of control instrumentation for the superconducting Linear Accelerator

    International Nuclear Information System (INIS)

    Joshi, Gopal; Kapatral, R.S.; Jha, K.; Rathod, N.C.; Sujo, C.I.; Ananthakrishnan, T.S.; Narsaiah, A.; Ghodgaonkar, M.D.; Kataria, S.K.; Singh, S.K.

    2001-01-01

    Electronics Division, BARC is developing the required control instrumentation for the Linear Accelerator (LINAC) coming up at TIFR. This consists of RF systems, CAMAC instruments and the Control and Information System. The control system consists of several identical Local Control Stations (LCS) connected over a LAN to a Main Control Station (MCS). Each LCS consists of a PC, CAMAC crates with functional Modules and RF systems. The MCS will contain two PCs running identical software. Each LCS will cater to two LINAC module each consisting of one cryostat and four resonators. This paper discusses different systems developed and under development in the Electronics Division which play an important role in the control of the LINAC. (author)

  9. Liquid scintillation spectrometer survey 155Eu liquid activity

    International Nuclear Information System (INIS)

    Zhang Zuhua

    2002-01-01

    In the countrywide contrasting survey of 155 Eu activity, 155 Eu liquid activity was determined for the first time through using liquid scintillation spectrometer survey 155 Eu β ray. In survey total uncertainty, determining activity accord with determining activity average value of all a wide variety of survey instrument entering into contrasting survey. But using liquid scintillation spectrometer survey, it is simple and save time, is beyond compare for other survey method. It indicate liquid scintillation spectrometer survey β-γ nuclide activity is effective as well

  10. Technological considerations in emergency instrumentation preparedness. Phase II-D. Evaluation testing and calibration methodology for emergency radiological instrumentation

    International Nuclear Information System (INIS)

    Bramson, P.E.; Andersen, B.V.; Fleming, D.M.; Kathren, R.L.; Mulhern, O.R.; Newton, C.E.; Oscarson, E.E.; Selby, J.M.

    1976-09-01

    In response to recommendations from the Advisory Committee on Reactor Safeguards, the Division of Operational Safety, U.S. ERDA has contracted with Battelle, Pacific Northwest Laboratories to survey the adequacy of existing instrumentation at nuclear fuel cycle facilities to meet emergency requirements and to develop technical criteria for instrumentation systems to be used in assessment of environmental conditions following plant emergencies. This report, the fifth in a series, provides: (1) calibration methods to assure the quality of radiological measurements and (2) testing procedures for determining whether an emergency radiological instrument meets the performance specifications. Three previous reports in this series identified the emergency instrumentation needs for power reactors, mixed oxide fuel plants, and fuel reprocessing facilities. Each of these three reports contains a Section VI, which sets forth applicable radiological instrument performance criteria and calibration requirements. Testing and calibration procedures in this report have been formatted in two parts: IV and V, each divided into three subsections: (1) Power Reactors, (2) Mixed Oxide Fuel Plants, and (3) Fuel Reprocessing Facilities. The three performance criteria subsections directly coincide with the performance criteria sections of the previous reports. These performance criteria sections have been reproduced in this report as Part III with references of ''required action'' added

  11. Inter-rater and test-retest reliability, internal consistency, and factorial structure of the instrument for forensic treatment evaluation

    NARCIS (Netherlands)

    Schuringa, E.; Spreen, M.; Bogaerts, S.

    2014-01-01

    In this study, the Instrument for Forensic Treatment Evaluation (IFTE) is introduced. The IFTE includes 14 dynamic items of the risk assessment scheme HKT-R and eight items specifically related to the treatment of forensic psychiatric patients. The items are divided over three factors: protective

  12. Trace Gas Retrievals from the GeoTASO Aircraft Instrument

    Science.gov (United States)

    Nowlan, C. R.; Liu, X.; Leitch, J. W.; Liu, C.; Gonzalez Abad, G.; Chance, K.; Cole, J.; Delker, T.; Good, W. S.; Murcray, F.; Ruppert, L.; Soo, D.; Loughner, C.; Follette-Cook, M. B.; Janz, S. J.; Kowalewski, M. G.; Pickering, K. E.; Zoogman, P.; Al-Saadi, J. A.

    2015-12-01

    The Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) instrument is a passive remote sensing instrument capable of making 2-D measurements of trace gases and aerosols from aircraft. The instrument measures backscattered UV and visible radiation, allowing the retrieval of trace gas amounts below the aircraft at horizontal resolutions on the order of 250 m x 250 m. GeoTASO was originally developed under NASA's Instrument Incubator Program as a test-bed instrument for the Geostationary Coastal and Air Pollution Events (GEO-CAPE) decadal survey mission, and is now also part of risk reduction for the upcoming Tropospheric Emissions: Monitoring of Pollution (TEMPO) and Geostationary Environment Monitoring Spectrometer (GEMS) geostationary satellite missions. We present spatially resolved observations of ozone, nitrogen dioxide, formaldehyde and sulfur dioxide over urban areas and power plants from flights during the DISCOVER-AQ field campaigns in Texas and Colorado, as well as comparisons with observations made by ground-based Pandora spectrometers, in situ monitoring instruments and other aircraft instruments deployed during these campaigns. These measurements at various times of day are providing a very useful data set for testing and improving TEMPO and GEMS retrieval algorithms, as well as demonstrating prototype validation strategies.

  13. Advanced Technologies and Instrumentation at the National Science Foundation

    Science.gov (United States)

    Kurczynski, Peter; Neff, James E.

    2018-01-01

    Over its more than thirty-year history, the Advanced Technologies and Instrumentation (ATI) program within the Division of Astronomical Sciences has provided grants to support the development and deployment of detectors and instrumentation for ground-based astronomy. This program has enabled scientific advances in diverse fields from solar physics to exoplanets to cosmology. ATI has provided instrumentation for both small and large observatories from radio through visible wavebands. It has played a role in the early development of major initiatives such as the Large Synoptic Survey Telescope. Technology development for astronomy unfolds over a longer period than the lifetime of a single grant. This review will consider ATI from an historical perspective to assess its impact on astronomy.

  14. 21 CFR 882.4560 - Stereotaxic instrument.

    Science.gov (United States)

    2010-04-01

    ...) Identification. A stereotaxic instrument is a device consisting of a rigid frame with a calibrated guide mechanism for precisely positioning probes or other devices within a patient's brain, spinal cord, or other part of the nervous system. (b) Classification. Class II (performance standards). ...

  15. Benefits of extensive recruitment effort persist during follow-ups and are consistent across age group and survey method. The TRAILS study.

    Science.gov (United States)

    Nederhof, Esther; Jörg, Frederike; Raven, Dennis; Veenstra, René; Verhulst, Frank C; Ormel, Johan; Oldehinkel, Albertine J

    2012-07-02

    assessment wave of a prospective population based cohort study has long lasting positive effects. Second, characteristics of hard-to-recruit responders are largely consistent across age groups and survey methods.

  16. Increased Science Instrumentation Funding Strengthens Mars Program

    Science.gov (United States)

    Graham, Lee D.; Graff, T. G.

    2012-01-01

    As the strategic knowledge gaps mature for the exploration of Mars, Mars sample return (MSR), and Phobos/Deimos missions, one approach that becomes more probable involves smaller science instrumentation and integrated science suites. Recent technological advances provide the foundation for a significant evolution of instrumentation; however, the funding support is currently too small to fully utilize these advances. We propose that an increase in funding for instrumentation development occur in the near-term so that these foundational technologies can be applied. These instruments would directly address the significant knowledge gaps for humans to Mars orbit, humans to the Martian surface, and humans to Phobos/ Deimos. They would also address the topics covered by the Decadal Survey and the Mars scientific goals, objectives, investigations and priorities as stated by the MEPAG. We argue that an increase of science instrumentation funding would be of great benefit to the Mars program as well as the potential for human exploration of the Mars system. If the total non-Earth-related planetary science instrumentation budget were increased 100% it would not add an appreciable amount to the overall NASA budget and would provide the real potential for future breakthroughs. If such an approach were implemented in the near-term, NASA would benefit greatly in terms of science knowledge of the Mars, Phobos/Deimos system, exploration risk mitigation, technology development, and public interest.

  17. Ninth Triennial Toxicology Salary Survey.

    Science.gov (United States)

    Gad, Shayne Cox; Sullivan, Dexter Wayne

    2016-01-01

    This survey serves as the ninth in a series of toxicology salary surveys conducted at 3-year intervals and beginning in 1988. An electronic survey instrument was distributed to 5919 individuals including members of the Society of Toxicology, American College of Toxicology, and 23 additional professional organizations. Question items inquired about gender, age, degree, years of experience, certifications held, areas of specialization, society membership, employment and income. Overall, 1293 responses were received (response rate 21.8%). The results of the 2014 survey provide insight into the job market and career path for current and future toxicologists. © The Author(s) 2016.

  18. Providing Consistent (A)ATSR Solar Channel Radiometry for Climate Studies

    Science.gov (United States)

    Smith, D.; Latter, B. G.; Poulsen, C.

    2012-04-01

    Data from the solar reflectance channels of the Along Track Scanning Radiometer (ATSR) series of instruments are being used in applications for monitoring trends in clouds and aerosols. In order to provide quantitative information, the radiometric calibrations of the sensors must be consistent, stable and ideally traced to international standards. This paper describes the methods used to monitor the calibrations of the ATSR instruments to provide consistent Level 1b radiometric data sets. Comparisons of the in-orbit calibrations are made by reference to data from quasi stable sites such as DOME-C in Antarctica or Saharan Desert sites. Comparisons are performed either by time coincident match-ups of the radiometric data for sensors having similar spectral bands and view/solar geometry and overpass times as for AATSR and MERIS; or via a reference BRDF model derived from averages of measurements over the site from a reference sensor where there is limited or no temporal overlap (e.g. MODIS-Aqua, ATSR-1 and ATSR-2). The results of the intercomparisons provide values of the long term calibration drift and systematic biases between the sensors. Look-up tables based on smoothed averages of the drift measurements are used to provide the corrections to Level 1b data. The uncertainty budgets for the comparisons are provided. It is also possible to perform comparisons of measurements against high spectral resolution instruments that are co-located on the same platform, i.e. AATSR/SCIA on ENVISAT and ATSR-2/GOME on ERS-2. The comparisons are performed by averaging the spectrometer data to the spectral response of the filter radiometer, and averaging the radiometer data to the spatial resolution of the spectrometer. In this paper, the authors present the results of the inter-comparisons to achieve a consistent calibration for the solar channels of the complete ATSR dataset. An assessment of the uncertainties associated with the techniques will be discussed. The impacts of the

  19. Instrument evaluation no. 10. Scanray radiation meter type 751

    CERN Document Server

    Burgess, P H; White, D F

    1978-01-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the a...

  20. Implementation Of Carlson Survey Software2009 In Survey Works And Comparison With CDS Software

    Directory of Open Access Journals (Sweden)

    Mohamed Faraj EL Megrahi

    2017-02-01

    Full Text Available The automation surveying is one of the most influential changes to surveying concept and profession has had to go through, this has taken effect in two major courses, hardware (instrumentation used in data collection and presentation, and the software (the applications used in data processing and manipulation. Automation is majorly computer based and just like all such systems is subject to improvement often; this is manifested in the new kinds of instrumentation models every few years such as total station and newer versions of software’s. The software that has the potential to completely affect survey automation is Carlson Surveying Software. This when coupled with total station as data processing and collection methods respectively; is capable of greatly improving productivity while reducing time and cost required in the long run. However, it is only natural for users to desire a competent software and be able to choose from what is available on the market based on guided research and credible information from previous researches. Such studies not only help in choice of software but are also handy when it comes to testing approaches and recommending improvements based on advantages and disadvantages to the manufacturers to help in advancement in the software industry for better and more comfortable use. The expected outcome of the research is a successful implementation of Carlson survey 2009 software in survey works and a comparison with other existing software like Civil Design Software (CDS was highlighted its advantages and disadvantages.

  1. Metallurgical characterization of controlled memory wire nickel-titanium rotary instruments.

    Science.gov (United States)

    Shen, Ya; Zhou, Hui-Min; Zheng, Yu-Feng; Campbell, Les; Peng, Bin; Haapasalo, Markus

    2011-11-01

    To improve the fracture resistance of nickel-titanium (NiTi) files, manufacturers have introduced new alloys and developed new manufacturing processes for the fabrication of NiTi files. This study aimed to examine the phase transformation behavior and microstructure of NiTi instruments from a novel controlled memory NiTi wire (CM wire). Instruments of EndoSequence (ES), ProFile (PF), ProFile Vortex (Vortex), Twisted Files (TF), Typhoon (TYP), and Typhoon™ CM (TYP CM), all size 25/.04, were examined by differential scanning calorimetry (DSC) and x-ray diffraction (XRD). Microstructures of etched instruments were observed by optical microscopy and scanning electron microscopy with x-ray energy-dispersive spectrometric (EDS) analyses. The DSC analyses showed that each segment of the TYP CM and Vortex instruments had an austenite transformation completion or austenite-finish (A(f)) temperature exceeding 37°C, whereas the NiTi instruments made from conventional superelastic NiTi wire (ES, PF, and TYP) and TF had A(f) temperatures substantially below mouth temperature. The higher A(f) temperature of TYP CM instruments was consistent with a mixture of austenite and martensite structure, which was observed at room temperature with XRD. All NiTi instruments had room temperature martensite microstructures consisting of colonies of lenticular features with substantial twinning. EDS analysis indicated that the precipitates in all NiTi instruments were titanium-rich, with an approximate composition of Ti(2)Ni. The TYP CM and Vortex instruments with heat treatment contribute to increase austenite transformation temperature. The CM instrument has significant changes in the phase transformation behavior, compared with conventional superelastic NiTi instruments. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. Validation of the "Quality of Life in School" instrument in Canadian elementary school students.

    Science.gov (United States)

    Ghotra, Satvinder; McIsaac, Jessie-Lee D; Kirk, Sara F L; Kuhle, Stefan

    2016-01-01

    Background. School is an integral component of the life of a child, and thus quality of school life is an important part of the overall quality of life experienced by a child. There are a few instruments available to measure the quality of school life but they are often not available in English, or they are not appropriate for use alongside other instruments in a survey of young children. The Quality of Life in School (QoLS) instrument is a short, self-report measure to assess elementary school students' perception of their quality of school life in four domains. The instrument was developed in Israel and has been validated among Hebrew-speaking children. The aim of the current study was to evaluate the psychometric properties of the QoLS measure in Canadian elementary school children. Methods. A total of 629 children attending grades 4-6 were recruited in a population-based cross-sectional study. The QoLS measure was administered to participating children by trained research assistants. In addition, their socio-demographic details and academic data were also obtained. The psychometric testing included exploratory factor analysis and reliability estimation using internal consistency (Cronbach's Alpha). Construct validity was investigated using the known groups comparisons for discriminative validity and via convergent validity. Results. A four-factor structure was generated explaining 39% of the total variance in the model. The results showed good internal consistency and acceptable floor and ceiling effects. Cronbach's Alpha ranged from 0.75 to 0.93. Known groups comparisons showed that the QoLS measure discriminated well between subgroups on the basis of gender, grade, and academic achievement, thus providing evidence of construct validity. The convergent validity was also appropriate with all the four domains demonstrating moderate to strong correlations to each other and to the total QoLS score. Conclusions. QoLS appears to be a valid and reliable measure for

  3. Moving beyond Traditional Methods of Survey Validation

    Science.gov (United States)

    Maul, Andrew

    2017-01-01

    In his focus article, "Rethinking Traditional Methods of Survey Validation," published in this issue of "Measurement: Interdisciplinary Research and Perspectives," Andrew Maul wrote that it is commonly believed that self-report, survey-based instruments can be used to measure a wide range of psychological attributes, such as…

  4. Measuring Instrument Constructs of Return Factors for Green Office Building Investments Variables Using Rasch Measurement Model

    Directory of Open Access Journals (Sweden)

    Isa Mona

    2016-01-01

    Full Text Available This paper is a preliminary study on rationalising green office building investments in Malaysia. The aim of this paper is attempt to introduce the application of Rasch measurement model analysis to determine the validity and reliability of each construct in the questionnaire. In achieving this objective, a questionnaire survey was developed consists of 6 sections and a total of 106 responses were received from various investors who own and lease office buildings in Kuala Lumpur. The Rasch Measurement analysis is used to measure the quality control of item constructs in the instrument by measuring the specific objectivity within the same dimension, to reduce ambiguous measures, and a realistic estimation of precision and implicit quality. The Rasch analysis consists of the summary statistics, item unidimensionality and item measures. A result shows the items and respondent (person reliability is at 0.91 and 0.95 respectively.

  5. The UV Survey Mission Concept, CETUS

    Science.gov (United States)

    Heap, Sara; and the CETUS Team

    2018-01-01

    In March 2017, NASA selected CETUS for study of a Probe-class mission concept. W. Danchi is the CETUS PI, and S. Heap is the Science PI. CETUS is primarily a UV survey telescope to complement survey telescopes of the 2020’s including E-ROSITA, Subaru Hyper Suprime Cam and Prime-Focus Spectrograph, WFIRST, and the Square Kilometer Array. CETUS comprises a 1.5-m wide-field telescope and three science instruments: a wide-field (1045” on a side) far-UV and near-UV camera; a similarly wide-field near-UV multi-object spectrograph utilizing a next-generation micro-shutter array; and a single-object spectrograph with options of spectral region (far-UV or near-UV) and spectral resolving power (2,000 or 40,000). The survey instruments will operate simultaneously thereby producing wide-field images in the near-UV and far-UV and a spectrogram containing near-UV spectra of up to 100 sources free of spectral overlap and astronomical background. ln concert with other survey telescopes, CETUS will focus on understanding galaxy evolution at cosmic noon (z~1-2).

  6. Robotic thin layer chromatography instrument for synthetic chemistry

    International Nuclear Information System (INIS)

    Corkan, L.A.; Haynes, E.; Kline, S.; Lindsey, J.S.

    1991-01-01

    We have constructed a second generation instrument for performing automated thin layer chromatography (TLC), The TLC instrument Consists of four dedicated stations for (1) plate dispensing, (2) sample application, (3) plate development, and (4) densitometry. A robot is used to move TLC plates among stations. The TLC instrument functions either as a stand-alone unit or as one analytical module in a robotic workstation for synthetic chemistry. An integrated hardware and software architecture enables automatic TLC analysis of samples produced concurrently from synthetic reactions in progress on the workstation. The combination of fixed automation and robotics gives a throughput of 12 TLC samples per hour. From these results a blueprint has emerged for an advanced automated TLC instrument with far greater throughput and analytical capabilities

  7. Programming for a nuclear reactor instrument simulator

    International Nuclear Information System (INIS)

    Cohn, C.E.

    1989-01-01

    A new computerized control system for a transient test reactor incorporates a simulator for pre-operational testing of control programs. The part of the simulator pertinent to the discussion here consists of two microprocessors. An 8086/8087 reactor simulator calculates simulated reactor power by solving the reactor kinetics equations. An 8086 instrument simulator takes the most recent power value developed by the reactor simulator and simulates the appropriate reading on each of the eleven reactor instruments. Since the system is required to run on a one millisecond cycle, careful programming was required to take care of all eleven instruments in that short time. This note describes the special programming techniques used to attain the needed performance

  8. Development and validation of a survey to measure features of clinical networks.

    Science.gov (United States)

    Brown, Bernadette Bea; Haines, Mary; Middleton, Sandy; Paul, Christine; D'Este, Catherine; Klineberg, Emily; Elliott, Elizabeth

    2016-09-30

    Networks of clinical experts are increasingly being implemented as a strategy to improve health care processes and outcomes and achieve change in the health system. Few are ever formally evaluated and, when this is done, not all networks are equally successful in their efforts. There is a need to formatively assess the strategic and operational management and leadership of networks to identify where functioning could be improved to maximise impact. This paper outlines the development and psychometric evaluation of an Internet survey to measure features of clinical networks and provides descriptive results from a sample of members of 19 diverse clinical networks responsible for evidence-based quality improvement across a large geographical region. Instrument development was based on: a review of published and grey literature; a qualitative study of clinical network members; a program logic framework; and consultation with stakeholders. The resulting domain structure was validated for a sample of 592 clinical network members using confirmatory factor analysis. Scale reliability was assessed using Cronbach's alpha. A summary score was calculated for each domain and aggregate level means and ranges are reported. The instrument was shown to have good construct validity across seven domains as demonstrated by a high level of internal consistency, and all Cronbach's α coefficients were equal to or above 0.75. In the survey sample of network members there was strong reported commitment and belief in network-led quality improvement initiatives, which were perceived to have improved quality of care (72.8 %) and patient outcomes (63.2 %). Network managers were perceived to be effective leaders and clinical co-chairs were perceived as champions for change. Perceived external support had the lowest summary score across the seven domains. This survey, which has good construct validity and internal reliability, provides a valid instrument to use in future research related to

  9. [Diffusion of clinical governance among the Italian Local Health Units (LHUs). Analysis of the Health Surveys, the Firm Acts and the Health Plans].

    Science.gov (United States)

    de Belvis, A G; Biasco, A; Pelone, F; Romaniello, A; De Micco, F; Volpe, M; Ricciardi, W

    2009-01-01

    The objective of our research is to report on the diffusion of Clinical Governance, as introduced with the National Health Plan 2006-2008, by analysing the planning instruments set up by each Region (Regional Health Plans and Emergency Plans in regions with budget deficit), the organizational frameworks (Atti Aziendali, firm acts), and the surveys on performance and quality of healthcare among the Italian Local Health Units (Health Surveys). Our research was realized on September-December 2007 and consisted of the collection of all retrieved documents available on the web and on the online public access catalog (OPAC SBN) of the National Library Service. Futhermore, each document has been classified and analysed according to Chambers' Clinical Governance definition. A descriptive statistical and inferential analysis by applying the Chi-2 Test was performed to test the correlation between the diffusion of such a classified documents and the geographical partition of each LHU. Our results show a scarce diffusion of Firm acts (43%) and Health Surveys (24.9% of the total). Any remind to Clinical Governance instruments and methods inside each document resulted even poorer among both the organizational and performance surveys and the regional health planning frameworks, respectively.

  10. Review of decametric radio astronomy - instruments and science

    International Nuclear Information System (INIS)

    Erickson, W.C.; Cane, H.V.

    1987-01-01

    The techniques and instruments used in Galactic and extragalactic radio astronomy at dkm wavelengths are surveyed, and typical results are summarized. Consideration is given to the large specialized phased arrays used for early surveys, the use of wideband elements to increase frequency agility, experimental VLBI observations, and limitations on ground-based observations below about 10 MHz (where the proposed LF Space Array, with resolution 0.5-5 arcmin, could make a major contribution). Observations discussed cover the Galactic center, the Galactic background radiation, SNRs, compact Galactic sources, the ISM, and large extragalactic sources. 38 references

  11. Measuring quality in community based housing support - the QPC-H instrument.

    Science.gov (United States)

    Lundqvist, Lars-Olov; Rask, Mikael; Brunt, David; Ivarsson, Ann-Britt; Schröder, Agneta

    2016-04-18

    Purpose - The purpose of this paper is to test the psychometric properties and dimensionality of the instrument Quality in Psychiatric Care-Housing (QPC-H) and briefly describe the residents' perception of quality of housing support. Design/methodology/approach - A sample of 174 residents from 22 housing support services in nine Swedish municipalities participated in the study. Confirmatory factor analysis (CFA) revealed that the QPC-H consisted of six dimensions and had a factor structure largely corresponding to that found among other instruments in the Quality in Psychiatric Care (QPC) family of instruments. Findings - CFA revealed that the QPC-H consisted of six dimensions and had a factor structure largely corresponding to that found among other instruments in the QPC family of instruments. The internal consistency of the factors was acceptable except in the case of secure and secluded environment, probably due to few numbers of items. With this exception, the QPC-H shows adequate psychometric properties. Social implications - The residents' ratings of quality of housing service were generally high; the highest rating was for secluded environment and the lowest for participation. This dimension would thus seem to indicate an important area for improvement. Originality/value - The QPC-H includes important aspects of residents' assessment of quality of housing service and offers a simple and inexpensive way to evaluate housing support services from the residents' perspective.

  12. Human performance in radiological survey scanning

    International Nuclear Information System (INIS)

    Brown, W.S.; Abelquist, E.W.

    1998-03-01

    The probability of detecting residual contamination in the field using portable radiological survey instruments depends not only on the sensitivity of the instrumentation used in scanning, but also on the surveyor's performance. This report provides a basis for taking human performance into account in determining the minimum level of activity detectable by scanning. A theoretical framework was developed (based on signal detection theory) which allows influences on surveyors to be anticipated and understood, and supports a quantitative assessment of performance. The performance of surveyors under controlled yet realistic field conditions was examined to gain insight into the task and to develop means of quantifying performance. Then, their performance was assessed under laboratory conditions to quantify more precisely their ability to make the required discriminations. The information was used to characterize surveyors' performance in the scanning task and to provide a basis for predicting levels of radioactivity that are likely to be detectable under various conditions by surveyors using portable survey instruments

  13. Human performance in radiological survey scanning

    Energy Technology Data Exchange (ETDEWEB)

    Brown, W.S. [Brookhaven National Lab., Upton, NY (United States); Abelquist, E.W. [Oak Ridge Inst. for Science and Education, TN (United States)

    1998-03-01

    The probability of detecting residual contamination in the field using portable radiological survey instruments depends not only on the sensitivity of the instrumentation used in scanning, but also on the surveyor`s performance. This report provides a basis for taking human performance into account in determining the minimum level of activity detectable by scanning. A theoretical framework was developed (based on signal detection theory) which allows influences on surveyors to be anticipated and understood, and supports a quantitative assessment of performance. The performance of surveyors under controlled yet realistic field conditions was examined to gain insight into the task and to develop means of quantifying performance. Then, their performance was assessed under laboratory conditions to quantify more precisely their ability to make the required discriminations. The information was used to characterize surveyors` performance in the scanning task and to provide a basis for predicting levels of radioactivity that are likely to be detectable under various conditions by surveyors using portable survey instruments.

  14. Using XML and Java for Astronomical Instrumentation Control

    Science.gov (United States)

    Ames, Troy; Koons, Lisa; Sall, Ken; Warsaw, Craig

    2000-01-01

    Traditionally, instrument command and control systems have been highly specialized, consisting mostly of custom code that is difficult to develop, maintain, and extend. Such solutions are initially very costly and are inflexible to subsequent engineering change requests, increasing software maintenance costs. Instrument description is too tightly coupled with details of implementation. NASA Goddard Space Flight Center is developing a general and highly extensible framework that applies to any kind of instrument that can be controlled by a computer. The software architecture combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML), a human readable and machine understandable way to describe structured data. A key aspect of the object-oriented architecture is software that is driven by an instrument description, written using the Instrument Markup Language (IML). ]ML is used to describe graphical user interfaces to control and monitor the instrument, command sets and command formats, data streams, and communication mechanisms. Although the current effort is targeted for the High-resolution Airborne Wideband Camera, a first-light instrument of the Stratospheric Observatory for Infrared Astronomy, the framework is designed to be generic and extensible so that it can be applied to any instrument.

  15. Results of the 2013 CASE Europe Salary Survey

    Science.gov (United States)

    Paradise, Andrew

    2013-01-01

    CASE has conducted salary surveys to track trends in the profession and to help members benchmark salaries since 1982. Following CASE's major overhaul of the survey instrument and data collection system, CASE Europe fielded a European version of the salary survey for the second time in October 2012. All individual CASE Europe members at colleges,…

  16. How Affectively-Based and Cognitively-Based Attitudes Drive Intergroup Behaviours: The Moderating Role of Affective-Cognitive Consistency

    Science.gov (United States)

    Zhou, Jie; Dovidio, John; Wang, Erping

    2013-01-01

    The moderating role of affective-cognitive consistency in the effects of affectively-based and cognitively-based attitudes on consummatory and instrumental behaviors was explored using two experimental studies in the intergroup context. Study 1 revealed that affectively-based attitudes were better predictors than cognitively-based attitudes regardless of affective-cognitive consistency for consummatory behaviors (e.g., undergraduates’ supportive behaviors toward government officials). Study 2, which investigated task groups’ supportive behaviors toward an immediate supervisory group, found that for these instrumental behaviors cognitively-based attitudes were better predictors than affectively-based attitudes only when affective-cognitive consistency was high. The present research also examined the mechanism by which affective-cognitive consistency moderates the relative roles of affectively-based and cognitively-based attitudes in attitude-behavior consistency. Results indicated that attitude-behavior consistency is eroded primarily because of the weaker relationship of affective or cognitive components to behaviors than to general attitudes. The reciprocal implications of research on attitudes and work on intergroup relations are considered. PMID:24244751

  17. Racial/ethnic differences in health insurance adequacy and consistency among children: Evidence from the 2011/12 National Survey of Children’s Health

    Directory of Open Access Journals (Sweden)

    Tulay G. Soylu

    2018-04-01

    Full Text Available Background: Surveillance of disparities in healthcare insurance, services and quality of care among children are critical for properly serving the medical/healthcare needs of underserved populations. The purpose of this study was to assess racial/ethnic differences in children’s (0 to 17 years old health insurance adequacy and consistency (child has insurance coverage for the last 12 months. Design and methods: We used data from the 2011/2012 National Survey of Children’s Health (n=79,474. Descriptive statistics and logistic regression analyses were conducted to examine the distribution and influence of several sociodemographic/family related factors on insurance adequacy and consistency across different racial/ethnic groups. Results: Stratified analyses by race/ethnicity revealed that white and black children living in households at or below 299% of the Federal Poverty Level (FPL were approximately 29 to 42% less likely to have adequate insurance compared to children living in families of higher income levels. Regardless of race/ethnicity, we found that children with public health insurance were more likely to have adequate insurance than their privately insured counterparts, while adolescents were at greater risk of inadequate coverage. Hispanic and black children were more likely to lack consistent insurance coverage. Conclusions: This study provides evidence that racial/ethnic differences in adequate and consistent health insurance exists with both white and minority children being affected adversely by poverty. Establishing outreach programs for low income families, and cross-cultural education for healthcare providers may help increase health insurance adequacy and consistency within certain underserved populations.

  18. Instrumental nuclear physics: elements for a proper choice

    International Nuclear Information System (INIS)

    1994-01-01

    This report consists of 11 documents about instrumental nuclear physics. It describes several detectors and data analysis techniques. Separate abstracts were prepared for all the papers in this volume. (TEC)

  19. The Aalborg Survey / Part 1 - Web Based Survey

    DEFF Research Database (Denmark)

    Harder, Henrik; Christensen, Cecilie Breinholm

    Background and purpose The Aalborg Survey consists of four independent parts: a web, GPS and an interview based survey and a literature study, which together form a consistent investigation and research into use of urban space, and specifically into young people’s use of urban space: what young......) and the research focus within the cluster of Mobility and Tracking Technologies (MoTT), AAU. Summary / Part 1 Web Base Survey The 1st part of the research project Diverse Urban Spaces (DUS) has been carried out during the period from December 1st 2007 to February 1st 2008 as a Web Based Survey of the 27.040 gross...... [statistikbanken.dk, a] young people aged 14-23 living in Aalborg Municipality in 2008. The web based questionnaire has been distributed among the group of young people studying at upper secondary schools in Aalborg, i.e. 7.680 young people [statistikbanken.dk, b]. The resulting data from those respondents who...

  20. The Aalborg Survey / Part 3 - Interview Based Survey

    DEFF Research Database (Denmark)

    Harder, Henrik; Christensen, Cecilie Breinholm; Jensen, Maria Vestergaard

    Background and purpose The Aalborg Survey consists of four independent parts: a web, GPS and an interview based survey and a literature study, which together form a consistent investigation and research into use of urban space, and specifically into young people’s use of urban space: what young...... people do in urban spaces, where they are in the urban spaces and when the young people are in the urban spaces. The answers to these questions form the framework and enable further academic discussions and conclusions in relation to the overall research project Diverse Urban Spaces (DUS). The primary......) and the research focus within the cluster of Mobility and Tracking Technologies (MoTT), AAU. Summary / Part 3 - Interview Based Survey The 3rd part of the DUS research project has been carried out during the fall of 2009 and the summer and fall of 2010 as an interview based survey of 18 selected participants (nine...

  1. Instrumental neutron activation analysis in environmental studies of trace elements

    International Nuclear Information System (INIS)

    Salmon, L.

    1975-06-01

    The application of a routine instrumental nuclear method is described in relation to environmental surveys and studies. A working rather than formal review is made of the techniques applied with particular reference to the data processing methods involved. The elements measured by instrumental activation analysis were: Ag, Al, As, Au, Ba, Br, Ca, Ce, Cl, Cd, Co, Cr, Cs, Cu, Fe, Hg, I, In, La, Mn, Na, Ni, Pb, Rb, Sb, Sc, Se, Th, Ti, U, V, W, Zn. (author)

  2. Satisfaction measurement instruments for healthcare service users: a systematic review

    OpenAIRE

    Almeida, Renato Santos de; Bourliataux-Lajoinie, Stephane; Martins, Mônica

    2015-01-01

    Patient satisfaction surveys can be an interesting way to improve quality and discuss the concept of patient-centered care. This study aimed to conduct a systematic review of the validated patient satisfaction measurement instruments applied in healthcare. The systematic review searched the MEDLINE/PubMed, LILACS, SciELO, Scopus and Web of Knowledge. The search strategy used the terms: "Patient Satisfaction" AND "Patient centered care" AND "Healthcare survey OR Satisfaction questionnaire" AND...

  3. Scientific instruments, scientific progress and the cyclotron

    International Nuclear Information System (INIS)

    Baird, David; Faust, Thomas

    1990-01-01

    Philosophers speak of science in terms of theory and experiment, yet when they speak of the progress of scientific knowledge they speak in terms of theory alone. In this article it is claimed that scientific knowledge consists of, among other things, scientific instruments and instrumental techniques and not simply of some kind of justified beliefs. It is argued that one aspect of scientific progress can be characterized relatively straightforwardly - the accumulation of new scientific instruments. The development of the cyclotron is taken to illustrate this point. Eight different activities which promoted the successful completion of the cyclotron are recognised. The importance is in the machine rather than the experiments which could be run on it and the focus is on how the cyclotron came into being, not how it was subsequently used. The completed instrument is seen as a useful unit of scientific progress in its own right. (UK)

  4. Survey Research: Methods, Issues and the Future

    Science.gov (United States)

    Brewer, Ernest W.; Torrisi-Steele, Geraldine; Wang, Victor C. X.

    2015-01-01

    Survey research is prevalent among many professional fields. Both cost effective and time efficient, this method of research is commonly used for the purposes of gaining insight into the attitudes, thoughts, and opinions of populations. Additionally, because there are several types of survey research designs and data collection instruments, the…

  5. Nuclear instrumentation for uranium exploration

    International Nuclear Information System (INIS)

    Sarma, Ch. V.N.; Sarma, C.V.R.; Sreehari, R.

    1999-01-01

    Instrumentation required for uranium exploration may be broadly classified based on surface and sub-surface measurement of gamma-ray intensity. Surface measurement of gross and spectral gamma intensity are carried out by employing portable Geiger Mueller/scintillation counters and four-channel spectrometers. Measurement of thoron ( 220 Rn) and radon ( 222 Rn) in the soil gas is being carried out by closed circuit technique using radon measuring system. Radiometric mapping of trenches, pits and mine-faces are carried out using shielded probe with 2π source geometry, whereas logging sonde with instruments through the steel armoured cable are employed for point to 4π geometry. Spectral borehole logging system with built-in multi-channel analyser (MCA) has been developed for the uranium exploration programme for AMD. Note-book PC based high sensitivity air-borne gamma-ray spectrometric survey system has been designed, developed and test flown. (author)

  6. A Frailty Instrument for primary care: findings from the Survey of Health, Ageing and Retirement in Europe (SHARE

    Directory of Open Access Journals (Sweden)

    Romero-Ortuno Roman

    2010-08-01

    Full Text Available Abstract Background A frailty paradigm would be useful in primary care to identify older people at risk, but appropriate metrics at that level are lacking. We created and validated a simple instrument for frailty screening in Europeans aged ≥50. Our study is based on the first wave of the Survey of Health, Ageing and Retirement in Europe (SHARE, http://www.share-project.org, a large population-based survey conducted in 2004-2005 in twelve European countries. Methods Subjects: SHARE Wave 1 respondents (17,304 females and 13,811 males. Measures: five SHARE variables approximating Fried's frailty definition. Analyses (for each gender: 1 estimation of a discreet factor (DFactor model based on the frailty variables using LatentGOLD®. A single DFactor with three ordered levels or latent classes (i.e. non-frail, pre-frail and frail was modelled; 2 the latent classes were characterised against a biopsychosocial range of Wave 1 variables; 3 the prospective mortality risk (unadjusted and age-adjusted for each frailty class was established on those subjects with known mortality status at Wave 2 (2007-2008 (11,384 females and 9,163 males; 4 two web-based calculators were created for easy retrieval of a subject's frailty class given any five measurements. Results Females: the DFactor model included 15,578 cases (standard R2 = 0.61. All five frailty indicators discriminated well (p N = 10,420; 66.9%, pre-frail (N = 4,025; 25.8%, and frail (N = 1,133; 7.3%. Relative to the non-frail class, the age-adjusted Odds Ratio (with 95% Confidence Interval for mortality at Wave 2 was 2.1 (1.4 - 3.0 in the pre-frail and 4.8 (3.1 - 7.4 in the frail. Males: 12,783 cases (standard R2 = 0.61, all frailty indicators had p N = 10,517; 82.3%, pre-frail (N = 1,871; 14.6%, and frail (N = 395; 3.1%; age-adjusted OR (95% CI for mortality: 3.0 (2.3 - 4.0 in the pre-frail, 6.9 (4.7 - 10.2 in the frail. Conclusions The SHARE Frailty Instrument has sufficient construct and

  7. The Prospects of Musical Instruments For People with Physical Disabilities

    DEFF Research Database (Denmark)

    Larsen, Jeppe Veirum; Overholt, Daniel; Moeslund, Thomas B.

    2016-01-01

    Many forms of enabling technologies exist today. While technologies aimed at enabling basic tasks in everyday life (locomotion, eating, etc.) are more common, musical instruments for people with disabilities can provide a chance for emotional enjoyment, as well as improve physical conditions thro...... instruments, music-supported therapy, and recent trends in the area. The overview is extrapolated to look at where the research is headed, providing insights for potential future work.......Many forms of enabling technologies exist today. While technologies aimed at enabling basic tasks in everyday life (locomotion, eating, etc.) are more common, musical instruments for people with disabilities can provide a chance for emotional enjoyment, as well as improve physical conditions...... through therapeutic use. The field of musical instruments for people with physical disabilities, however, is still an emerging area of research. In this article, we look at the current state of developments, including a survey of custom designed instruments, augmentations / modifications of existing...

  8. Quality Control in Survey Design: Evaluating a Survey of Educators’ Attitudes Concerning Differentiated Compensation

    OpenAIRE

    Kelly D. Bradley; Michael Peabody; Shannon O. Sampson

    2015-01-01

    This study utilized the Rasch model to assess the quality of a survey instrument designed to measure attitudes of administrators and teachers concerning a differentiated teacher compensation program piloted in Kentucky.  Researchers addressing potentially contentious issues should ensure their methods stand up to rigorous criticism.  The results indicate that the rating scale does not function as expected, with items being too easy to endorse.  Future iterations of this survey should be revis...

  9. Measuring participants' immersion in healthcare simulation: the development of an instrument.

    Science.gov (United States)

    Hagiwara, Magnus Andersson; Backlund, Per; Söderholm, Hanna Maurin; Lundberg, Lars; Lebram, Mikael; Engström, Henrik

    2016-01-01

    Immersion is important for simulation-based education; however, questionnaire-based instruments to measure immersion have some limitations. The aim of the present work is to develop a new instrument to measure immersion among participants in healthcare simulation scenarios. The instrument was developed in four phases: trigger identification, content validity scores, inter-rater reliability analysis and comparison with an existing immersion measure instrument. A modified Delphi process was used to develop the instrument and to establish validity and reliability. The expert panel consisted of 10 researchers. All the researchers in the team had previous experience of simulation in the health and/or fire and rescue services as researchers and/or educators and simulation designers. To identify triggers, the panel members independently screened video recordings from simulation scenarios. Here, a trigger is an event in a simulation that is considered a sign of reduced or enhanced immersion among simulation participants. The result consists of the Immersion Score Rating Instrument (ISRI). It contains 10 triggers, of which seven indicate reduced and three enhanced immersion. When using ISRI, a rater identifies trigger occurrences and assigns them strength between 1 and 3. The content validity analysis shows that all the 10 triggers meet an acceptable content validity index for items (I-CVI) standard. The inter-rater reliability (IRR) among raters was assessed using a two-way mixed, consistency, average-measures intra-class correlation (ICC). The ICC for the difference between weighted positive and negative triggers was 0.92, which indicates that the raters are in agreement. Comparison with results from an immersion questionnaire mirrors the ISRI results. In conclusion, we present a novel and non-intrusive instrument for identifying and rating the level of immersion among participants in healthcare simulation scenarios.

  10. CARMENES instrument control system and operational scheduler

    Science.gov (United States)

    Garcia-Piquer, Alvaro; Guàrdia, Josep; Colomé, Josep; Ribas, Ignasi; Gesa, Lluis; Morales, Juan Carlos; Pérez-Calpena, Ana; Seifert, Walter; Quirrenbach, Andreas; Amado, Pedro J.; Caballero, José A.; Reiners, Ansgar

    2014-07-01

    The main goal of the CARMENES instrument is to perform high-accuracy measurements of stellar radial velocities (1m/s) with long-term stability. CARMENES will be installed in 2015 at the 3.5 m telescope in the Calar Alto Observatory (Spain) and it will be equipped with two spectrographs covering from the visible to the near-infrared. It will make use of its near-IR capabilities to observe late-type stars, whose peak of the spectral energy distribution falls in the relevant wavelength interval. The technology needed to develop this instrument represents a challenge at all levels. We present two software packages that play a key role in the control layer for an efficient operation of the instrument: the Instrument Control System (ICS) and the Operational Scheduler. The coordination and management of CARMENES is handled by the ICS, which is responsible for carrying out the operations of the different subsystems providing a tool to operate the instrument in an integrated manner from low to high user interaction level. The ICS interacts with the following subsystems: the near-IR and visible channels, composed by the detectors and exposure meters; the calibration units; the environment sensors; the front-end electronics; the acquisition and guiding module; the interfaces with telescope and dome; and, finally, the software subsystems for operational scheduling of tasks, data processing, and data archiving. We describe the ICS software design, which implements the CARMENES operational design and is planned to be integrated in the instrument by the end of 2014. The CARMENES operational scheduler is the second key element in the control layer described in this contribution. It is the main actor in the translation of the survey strategy into a detailed schedule for the achievement of the optimization goals. The scheduler is based on Artificial Intelligence techniques and computes the survey planning by combining the static constraints that are known a priori (i.e., target

  11. Designing an Instrument to Measure the QoS of a Spanish Virtual Store

    Science.gov (United States)

    de Abajo, Beatriz Sainz; de La Torre Díez, Isabel; Salcines, Enrique García; Fernández, Javier Burón; Pernas, Francisco Díaz; Coronado, Miguel López; de Castro Lozano, Carlos

    This article describes the development of an instrument, in the form of a survey, which is distributed to users of a B2C website selling electronic books in order to ascertain their satisfaction. The opinions compiled from a pilot sample and the exploratory factor analysis carried out point to factors that best summarise the quality of the application analysed here. Analysis of the initial survey, with a total of 40 items, shaped the final instrument, encompassing 18 items divided into 6 dimensions, which measure the perceptions of users of the application in order to improve the contents of the website. Subsequently, a confirmatory factorial analysis is performed, ensuring the reliability of the study and which confirms that the structure of the instrument developed truly measures service quality in accordance with the requirements of the website in terms of offering a space that fulfils consumer expectations in the Information Society.

  12. Engineering surveying theory and examination problems for students

    CERN Document Server

    Schofield, W

    2013-01-01

    Engineering Surveying: Theory and Examination Problems for Students, Volume 1, Third Edition discusses topics concerning engineering surveying techniques and instrumentations. The book is comprised of eight chapters that cover several concerns in engineering survey. Chapter 1 discusses the basic concepts of surveying. Chapter 2 deals with simple and precise leveling, while Chapter 3 covers earthworks. The book also talks about the theodolite and its applications, and then discusses optical distance measurement. Curves, underground and hydrographic surveying, and aspects of dimensional control

  13. Aerial radiological survey of the area surrounding the Edwin I. Hatch Nuclear Plant, Baxley, Georgia

    International Nuclear Information System (INIS)

    Hilton, L.K.

    1978-11-01

    An airborne radiological survey of a 2146 km 2 area surrounding the Edwin I. Hatch Nuclear Plant was made 28-31 March 1977. Detected radioisotopes, and their associated gamma ray exposure rates, were consistent with that expected from the normal background emitters. Count rates observed at 152 m altitude are converted to equivalent exposure rates at 1 m above the ground, and are presented in the form of an isopleth map. Exposure rates measured with small portable instruments and soil sample analysis showed agreement with the airborne data

  14. Cosmological consistency tests of gravity theory and cosmic acceleration

    Science.gov (United States)

    Ishak-Boushaki, Mustapha B.

    2017-01-01

    Testing general relativity at cosmological scales and probing the cause of cosmic acceleration are among the important objectives targeted by incoming and future astronomical surveys and experiments. I present our recent results on consistency tests that can provide insights about the underlying gravity theory and cosmic acceleration using cosmological data sets. We use statistical measures, the rate of cosmic expansion, the growth rate of large scale structure, and the physical consistency of these probes with one another.

  15. Internally consistent gamma ray burst time history phenomenology

    International Nuclear Information System (INIS)

    Cline, T.L.

    1985-01-01

    A phenomenology for gamma ray burst time histories is outlined. Order of their generally chaotic appearance is attempted, based on the speculation that any one burst event can be represented above 150 keV as a superposition of similarly shaped increases of varying intensity. The increases can generally overlap, however, confusing the picture, but a given event must at least exhibit its own limiting characteristic rise and decay times if the measurements are made with instruments having adequate temporal resolution. Most catalogued observations may be of doubtful or marginal utility to test this hypothesis, but some time histories from Helios-2, Pioneer Venus Orbiter and other instruments having one-to several-millisecond capabilities appear to provide consistency. Also, recent studies of temporally resolved Solar Maximum Mission burst energy spectra are entirely compatible with this picture. The phenomenology suggested here, if correct, may assist as an analytic tool for modelling of burst processes and possibly in the definition of burst source populations

  16. PEP surveying procedures and equipment

    International Nuclear Information System (INIS)

    Linker, F.

    1982-06-01

    The PEP Survey and Alignment System, which employs both laser-based and optical survey methods, is described. The laser is operated in conjunction with the Tektronix 4051 computer and surveying instruments such as ARM and SAM, system which is designed to automate data input, reduction, and production of alignment instructions. The laser system is used when surveying ring quadrupoles, main bend magnets, sextupoles, and is optional when surveying RF cavities and insertion quadrupoles. Optical methods usually require that data be manually entered into the computer for alignment, but in some cases, an element can be aligned using nominal values of fiducial locations without use of the computer. Optical surveying is used in the alignment of NIT and SIT, low field bend magnets, wigglers, RF cavities, and insertion quadrupoles

  17. Validation of the Care-Related Quality of Life Instrument in different study settings: findings from The Older Persons and Informal Caregivers Survey Minimum DataSet (TOPICS-MDS).

    Science.gov (United States)

    Lutomski, J E; van Exel, N J A; Kempen, G I J M; Moll van Charante, E P; den Elzen, W P J; Jansen, A P D; Krabbe, P F M; Steunenberg, B; Steyerberg, E W; Olde Rikkert, M G M; Melis, R J F

    2015-05-01

    Validity is a contextual aspect of a scale which may differ across sample populations and study protocols. The objective of our study was to validate the Care-Related Quality of Life Instrument (CarerQol) across two different study design features, sampling framework (general population vs. different care settings) and survey mode (interview vs. written questionnaire). Data were extracted from The Older Persons and Informal Caregivers Minimum DataSet (TOPICS-MDS, www.topics-mds.eu ), a pooled public-access data set with information on >3,000 informal caregivers throughout the Netherlands. Meta-correlations and linear mixed models between the CarerQol's seven dimensions (CarerQol-7D) and caregiver's level of happiness (CarerQol-VAS) and self-rated burden (SRB) were performed. The CarerQol-7D dimensions were correlated to the CarerQol-VAS and SRB in the pooled data set and the subgroups. The strength of correlations between CarerQol-7D dimensions and SRB was weaker among caregivers who were interviewed versus those who completed a written questionnaire. The directionality of associations between the CarerQol-VAS, SRB and the CarerQol-7D dimensions in the multivariate model supported the construct validity of the CarerQol in the pooled population. Significant interaction terms were observed in several dimensions of the CarerQol-7D across sampling frame and survey mode, suggesting meaningful differences in reporting levels. Although good scientific practice emphasises the importance of re-evaluating instrument properties in individual research studies, our findings support the validity and applicability of the CarerQol instrument in a variety of settings. Due to minor differential reporting, pooling CarerQol data collected using mixed administration modes should be interpreted with caution; for TOPICS-MDS, meta-analytic techniques may be warranted.

  18. Benefits of extensive recruitment effort persist during follow-ups and are consistent across age group and survey method. The TRAILS study

    Directory of Open Access Journals (Sweden)

    Nederhof Esther

    2012-07-01

    . Conclusions First, extensive recruitment effort at the first assessment wave of a prospective population based cohort study has long lasting positive effects. Second, characteristics of hard-to-recruit responders are largely consistent across age groups and survey methods.

  19. Benefits of extensive recruitment effort persist during follow-ups and are consistent across age group and survey method. The TRAILS study

    Science.gov (United States)

    2012-01-01

    recruitment effort at the first assessment wave of a prospective population based cohort study has long lasting positive effects. Second, characteristics of hard-to-recruit responders are largely consistent across age groups and survey methods. PMID:22747967

  20. Tesla VUPJT instruments for radiation monitoring of working environment and selected aplications

    International Nuclear Information System (INIS)

    Slezak, V.; Kula, J.; Novakova, O.; Jursova, L.; Severa, L.

    1986-01-01

    A survey is presented of the current state of development and production of instruments for ionizing radiation monitoring and detection, also listing possible applications in the national economy. (author)

  1. FY 2000 report on the results of the research and development project for the photon-aided instrumentation and processing technologies. R and D of the photon-aided instrumentation and processing technologies; 2000 nendo photon keisoku kako gijutsu seika hokokusho. Photon keisoku kako gijutsu no kenkyu kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Described herein are the FY 2000 results of development of the photon-aided instrumentation and processing technologies. The technological and R and D trends of the photon-aided instrumentation and processing technologies are surveyed, in order to clarify the directions of their impacts and ripple effects on creation of new industries and development of the existing industries. The survey committee is organized, for exchanging opinions and information, and collection of information. For the trends of the photon-aided processing technologies, information on the elementary and peripheral technologies is collected by literature survey and academic meetings for processing, applied instrumentation and analysis, and photon generation/controlling, to grasp, analyze and study the latest trends. For the photon-utilizing technologies, information is collected viewed from their application to wide industrial areas, e.g., medical, diagnostic, communication/transmission, multimedia and chemical areas, other than those for instrumentation and processing. Also surveyed and analyzed/studied are the technologies for environmental protection, sensing, information, and the new areas, e.g., terahertz photonics and agriculture. (NEDO)

  2. LAMOST spectral survey — An overview

    International Nuclear Information System (INIS)

    Zhao Gang; Zhao Yongheng; Chu Yaoquan; Deng Licai; Jing Yipeng

    2012-01-01

    LAMOST (Large sky Area Multi-Object fiber Spectroscopic Telescope) is a Chinese national scientific research facility operated by National Astronomical Observatories, Chinese Academy of Sciences (NAOC). After two years of commissioning beginning in 2009, the telescope, instruments, software systems and operations are nearly ready to begin the main science survey. Through a spectral survey of millions of objects in much of the northern sky, LAMOST will enable research in a number of contemporary cutting edge topics in astrophysics, such as discovery of the first generation stars in the Galaxy, pinning down the formation and evolution history of galaxies — especially the Milky Way and its central massive black hole, and looking for signatures of the distribution of dark matter and possible sub-structures in the Milky Way halo. To maximize the scientific potential of the facility, wide national participation and international collaboration have been emphasized. The survey has two major components: the LAMOST ExtraGAlactic Survey (LEGAS) and the LAMOST Experiment for Galactic Understanding and Exploration (LEGUE). Until LAMOST reaches its full capability, the LEGUE portion of the survey will use the available observing time, starting in 2012. An overview of the LAMOST project and the survey that will be carried out in the next five to six years is presented in this paper. The science plan for the whole LEGUE survey, instrumental specifications, site conditions, and the descriptions of the current on-going pilot survey, including its footprints and target selection algorithm, will be presented as separate papers in this volume.

  3. Development and pilot of an international survey: 'Radiation Therapists and Psychosocial Support'.

    Science.gov (United States)

    Elsner, Kelly L; Naehrig, Diana; Halkett, Georgia K B; Dhillon, Haryana M

    2018-06-07

    Up to one third of radiation therapy patients are reported to have unmet psychosocial needs. Radiation therapists (RTs) have daily contact with patients and can provide daily psychosocial support to reduce patient anxiety, fear and loneliness. However, RTs vary in their values, skills, training, knowledge and involvement in providing psychosocial support. The aims of this study were to: (1) develop an online survey instrument to explore RT values, skills, training and knowledge regarding patient anxiety and psychosocial support, and (2) pilot the instrument with RT professionals to assess content validity, functionality and length. An online cross-sectional survey, titled 'Radiation therapists and psychosocial support' was developed. Items included patient vignettes, embedded items from RT research, and the Professional Quality of Life Scale (ProQOL5). Four radiation oncology departments volunteered to pilot the survey; each nominated four RT staff to participate. Survey data were analysed descriptively and qualitative feedback grouped and coded to determine whether the survey needed to be refined. Thirteen of sixteen RTs completed the pilot survey and feedback form. Median time to completion was 35 mins, with 54% of respondents stating this was too long. Respondents reported content, questions and response options were relevant and appropriate. Feedback was used to: refine the survey instrument, minimise responder burden and drop out and improve functionality and quality of data collection. This pilot of the 'Radiation therapists and psychosocial support' survey instrument demonstrated content validity and usability. The main survey will be circulated to a representative sample of RTs for completion. © 2018 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology.

  4. Concurrent validation of two key health literacy instruments in a South Eastern European population.

    Science.gov (United States)

    Toçi, Ervin; Burazeri, Genc; Sørensen, Kristine; Kamberi, Haxhi; Brand, Helmut

    2015-06-01

    Public health practice has come to increasing recognition of health promotion and the central role of knowledge, attitude, beliefs and practices in achieving health promotion. Health literacy (HL) is an under-explored topic in South Eastern European countries. There are no HL reports from Albania to date. The aim of this study was to assess the concurrent validity of the European Health Literacy Survey Questionnaire (HLS-EU-Q) and the Test of Functional Health Literacy in Adults (TOFHLA) in a population-based sample of adults in Albania. A cross-sectional study was conducted in 2013 in Tirana, Albania, including 239 individuals aged ≥ 18 years (61% women; 87% response). A structured interviewer-administered questionnaire was applied twice (test and retest procedure after 2 weeks) including HLS-EU-Q and TOFHLA instruments. The internal consistency was high for both instruments (Cronbach's alpha for the test procedure was 0.92 for TOFHLA and 0.98 for HLS-EU-Q). Both tools exhibited a high stability over time (Spearman's rho: 0.88 for TOFHLA and 0.87 for HLS-EU). Mean values of both instruments were similar in men and women (mean score for TOFHLA: 76.0 vs. 76.5, P = 0.83; mean score for HLS-EU-Q: 32.2 vs. 32.6, P = 0.63). For both instruments, higher HL scores were significantly associated with younger age, higher educational and economic level and lower body mass index. Our study provides valuable novel evidence on concurrent validation of two major HL instruments in a South Eastern European population-based sample. Future studies should be conducted in order to confirm and expand our findings. © The Author 2014. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.

  5. Evaluation of a draft standard on performance specifications for health physics instrumentation. Initial results for radiological tests

    International Nuclear Information System (INIS)

    Swinth, K.L.; Kenoyer, J.L.; Mileham, A.P.; Kathren, R.L.; Selby, J.M.

    1983-06-01

    The draft ANSI standard N42.17D2 on performance specifications for health physics instrumentation is currently being evaluated by the Pacific Northwest Laboratory. The primary objective of the project is the evaluation of the applicability and practicality of the proposed standard through testing of a cross-section of currently available commercial instruments to determine how well they conform to the standard. The standard is being tested against instruments such as ionization chambers, G.M. detectors, alpha survey meters, and neutron dose equivalent survey meters. This paper presents results of the preliminary radiological performance tests on ionization chambers and G.M. detectors. This includes both the data generated during the tests and a discussion of procedures developed to perform the testing. Results are reported for response time, accuracy, precision, radiation overloads, and angular dependence. In addition, results are reported for parameters that affect instrument performance including battery lifetime, geotropism and stability. Initial test indicates that some of the instruments will not meet the criteria specified in ANSI N42.17D2. Results cover approximately 40 instruments that have been obtained by direct purchase, by loan from instrument vendors or by loan from others including DOE licensees

  6. Novel seismic instrumentation for nuclear power plants

    International Nuclear Information System (INIS)

    Bolleter, W.; Savary, C.

    1998-01-01

    Conforming to the latest issues of the Nuclear Regulatory Commission Regulatory Guide, a novel hardware and software solution for seismic instrumentation is presented. Both instrumentation and PC-based data evaluation software for post-earthquake actions are type-tested and approved by the German TUeV. Reference installations replacing obsolete analog instrumentation were successfully completed and are presented. The instrumentation consists of highly linear, solid-state capacitive accelerometers as well as digital recorders storing the signals from the sensors in situ. These recorders are linked in a star-topology network to a central unit that permanently communicates with them via fiber-optic cable or current-loop links. The central unit is responsible for alerting and synchronizes all recorders which otherwise act autonomously. Data evaluation is handled by a PC-based software package. It includes automatic data evaluation after earthquakes (batch mode), interactive data evaluation software for detailed data analysis, and software tools for remote operation, maintenance and data storage. (author)

  7. Feedback to Managers, Volume II: A Review and Comparison of Sixteen Multi-Rater Feedback Instruments.

    Science.gov (United States)

    Van Velsor, Ellen; Leslie, Jean Brittain

    "Feedback to Managers" is a two-volume report. Volume 2 compares 16 of the better feedback instruments available. The following are the instruments: (1) ACUMEN Group Feedback; (2) BENCHMARKS; (3) the Campbell Leadership Index; (4) COMPASS: the Managerial Practices Survey; (5) the Executive Success Profile; (6) Leader Behavior Analysis…

  8. the research quality plus (rq+) assessment instrument

    International Development Research Centre (IDRC) Digital Library (Canada)

    Thomas Schwandt

    THE RESEARCH QUALITY PLUS (RQ+) ASSESSMENT INSTRUMENT ... consistent way to allow for further meta-analysis about research quality over time. ... Addresses complex and integrative problems, requiring systems-based approaches ..... benefits or financial costs for participants that might not be appropriate in the ...

  9. The Basic Design Report of the 40M SANS Instrument

    Energy Technology Data Exchange (ETDEWEB)

    Han, Young Soo; Lee, Chang Hee; Hwang, Dong Gil; Kim, Hak Rho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Tae Hwan; Choi, Sung Min [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2006-04-15

    The HANARO cold neutron research facility project was launched on July 1, 2003. A state of the art SANS instrument was selected as a top-priority instrument by an instrument selection committee, which consisted of domestic users and HANARO personnel. An instrument development team and an international and domestic instrument advisory team were formulated. The guide and the instrument simulation were performed using Vitess software and the optimum basic design was completed based on the simulation results and the international advisory team reviews. The optimum design of the guide for the 40M SANS instrument was completed and the optimum basic design of the 40M the SANS instrument was also completed based on the Vitess simulation results. The Q range of the instrument will cover from 0.0008 to 1.0 A-1 and the maximum flux at a sample position can reach about 5.5x10 7 n/cm2sec. The simulation results and the basic design product will be used for the detailed design and the construction of the SANS instrument. The simulation results could be applied to the development of the other instrument.

  10. The Ostomy-Q: Development and Psychometric Validation of an Instrument to Evaluate Outcomes Associated with Ostomy Appliances.

    Science.gov (United States)

    Nafees, Beenish; Rasmussen, Mikkel; LLoyd, Andrew

    2017-01-01

    Using an ostomy appliance can affect many aspects of a person's health-related quality of life (HRQL). A 2-part, descrip- tive study was designed to develop and validate an instrument to assess quality-of-life outcomes related to ostomy ap- pliance use. Study inclusion/exclusion criteria stipulated participants should be 18 to 85 years of age, have an ileostomy or colostomy, used an appliance for a minimum of 3 months without assistance, and able to complete an online survey. All participants provided sociodemographic and clinical information. In phase 1, a literature search was conducted and existing instruments used to measure HRQL in persons with an ostomy were assessed. Subsequently, the Ostomy-Q, a 23-item, Likert-response type questionnaire, divided into 4 domains (Discreetness, Comfort, Confidence, and Social Life), was developed based on published evidence and existing ostomy-related HRQL tools. Seven (7) participants re- cruited from a manufacturer user panel took part in exploratory/cognitive qualitative interviews to refine the new quality- of-life questionnaire. In phase 2, the instrument was tested to assess item variability and conceptual structure, item-total correlation, internal consistency, test-retest reliability, sensitivity, and minimal important difference (MID) in an online validation study among 200 participants from the manufacturer's user panel (equally divided by gender, 125 [62.5%] >50 years old, 128 [64%] with an ileostomy). This exercise also included completion of the Stoma Quality of Life Question- naire and 2 domains from the Ostomy Adjustment Inventory-23 to assess convergent validity. Eighty-two (82) participants recompleted these study instruments 2 weeks later to assess test-retest reliability. Sociodemographic and clinical data were assessed using descriptive statistics; Cronbach's alpha was used for internal consistency (minimum 0.70), principle component analysis for item variability/conceptual structure, and item

  11. Development and Psychometric Evaluation of an Instrument to Assess Cross-Cultural Competence of Healthcare Professionals (CCCHP)

    Science.gov (United States)

    Bernhard, Gerda; Knibbe, Ronald A.; von Wolff, Alessa; Dingoyan, Demet; Schulz, Holger; Mösko, Mike

    2015-01-01

    Background Cultural competence of healthcare professionals (HCPs) is recognized as a strategy to reduce cultural disparities in healthcare. However, standardised, valid and reliable instruments to assess HCPs’ cultural competence are notably lacking. The present study aims to 1) identify the core components of cultural competence from a healthcare perspective, 2) to develop a self-report instrument to assess cultural competence of HCPs and 3) to evaluate the psychometric properties of the new instrument. Methods The conceptual model and initial item pool, which were applied to the cross-cultural competence instrument for the healthcare profession (CCCHP), were derived from an expert survey (n = 23), interviews with HCPs (n = 12), and a broad narrative review on assessment instruments and conceptual models of cultural competence. The item pool was reduced systematically, which resulted in a 59-item instrument. A sample of 336 psychologists, in advanced psychotherapeutic training, and 409 medical students participated, in order to evaluate the construct validity and reliability of the CCCHP. Results Construct validity was supported by principal component analysis, which led to a 32-item six-component solution with 50% of the total variance explained. The different dimensions of HCPs’ cultural competence are: Cross-Cultural Motivation/Curiosity, Cross-Cultural Attitudes, Cross-Cultural Skills, Cross-Cultural Knowledge/Awareness and Cross-Cultural Emotions/Empathy. For the total instrument, the internal consistency reliability was .87 and the dimension’s Cronbach’s α ranged from .54 to .84. The discriminating power of the CCCHP was indicated by statistically significant mean differences in CCCHP subscale scores between predefined groups. Conclusions The 32-item CCCHP exhibits acceptable psychometric properties, particularly content and construct validity to examine HCPs’ cultural competence. The CCCHP with its five dimensions offers a comprehensive

  12. Development and Psychometric Evaluation of an Instrument to Assess Cross-Cultural Competence of Healthcare Professionals (CCCHP).

    Science.gov (United States)

    Bernhard, Gerda; Knibbe, Ronald A; von Wolff, Alessa; Dingoyan, Demet; Schulz, Holger; Mösko, Mike

    2015-01-01

    Cultural competence of healthcare professionals (HCPs) is recognized as a strategy to reduce cultural disparities in healthcare. However, standardised, valid and reliable instruments to assess HCPs' cultural competence are notably lacking. The present study aims to 1) identify the core components of cultural competence from a healthcare perspective, 2) to develop a self-report instrument to assess cultural competence of HCPs and 3) to evaluate the psychometric properties of the new instrument. The conceptual model and initial item pool, which were applied to the cross-cultural competence instrument for the healthcare profession (CCCHP), were derived from an expert survey (n = 23), interviews with HCPs (n = 12), and a broad narrative review on assessment instruments and conceptual models of cultural competence. The item pool was reduced systematically, which resulted in a 59-item instrument. A sample of 336 psychologists, in advanced psychotherapeutic training, and 409 medical students participated, in order to evaluate the construct validity and reliability of the CCCHP. Construct validity was supported by principal component analysis, which led to a 32-item six-component solution with 50% of the total variance explained. The different dimensions of HCPs' cultural competence are: Cross-Cultural Motivation/Curiosity, Cross-Cultural Attitudes, Cross-Cultural Skills, Cross-Cultural Knowledge/Awareness and Cross-Cultural Emotions/Empathy. For the total instrument, the internal consistency reliability was .87 and the dimension's Cronbach's α ranged from .54 to .84. The discriminating power of the CCCHP was indicated by statistically significant mean differences in CCCHP subscale scores between predefined groups. The 32-item CCCHP exhibits acceptable psychometric properties, particularly content and construct validity to examine HCPs' cultural competence. The CCCHP with its five dimensions offers a comprehensive assessment of HCPs' cultural competence, and has the

  13. The Hyper Suprime-Cam SSP Survey: Overview and survey design

    Science.gov (United States)

    Aihara, Hiroaki; Arimoto, Nobuo; Armstrong, Robert; Arnouts, Stéphane; Bahcall, Neta A.; Bickerton, Steven; Bosch, James; Bundy, Kevin; Capak, Peter L.; Chan, James H. H.; Chiba, Masashi; Coupon, Jean; Egami, Eiichi; Enoki, Motohiro; Finet, Francois; Fujimori, Hiroki; Fujimoto, Seiji; Furusawa, Hisanori; Furusawa, Junko; Goto, Tomotsugu; Goulding, Andy; Greco, Johnny P.; Greene, Jenny E.; Gunn, James E.; Hamana, Takashi; Harikane, Yuichi; Hashimoto, Yasuhiro; Hattori, Takashi; Hayashi, Masao; Hayashi, Yusuke; Hełminiak, Krzysztof G.; Higuchi, Ryo; Hikage, Chiaki; Ho, Paul T. P.; Hsieh, Bau-Ching; Huang, Kuiyun; Huang, Song; Ikeda, Hiroyuki; Imanishi, Masatoshi; Inoue, Akio K.; Iwasawa, Kazushi; Iwata, Ikuru; Jaelani, Anton T.; Jian, Hung-Yu; Kamata, Yukiko; Karoji, Hiroshi; Kashikawa, Nobunari; Katayama, Nobuhiko; Kawanomoto, Satoshi; Kayo, Issha; Koda, Jin; Koike, Michitaro; Kojima, Takashi; Komiyama, Yutaka; Konno, Akira; Koshida, Shintaro; Koyama, Yusei; Kusakabe, Haruka; Leauthaud, Alexie; Lee, Chien-Hsiu; Lin, Lihwai; Lin, Yen-Ting; Lupton, Robert H.; Mandelbaum, Rachel; Matsuoka, Yoshiki; Medezinski, Elinor; Mineo, Sogo; Miyama, Shoken; Miyatake, Hironao; Miyazaki, Satoshi; Momose, Rieko; More, Anupreeta; More, Surhud; Moritani, Yuki; Moriya, Takashi J.; Morokuma, Tomoki; Mukae, Shiro; Murata, Ryoma; Murayama, Hitoshi; Nagao, Tohru; Nakata, Fumiaki; Niida, Mana; Niikura, Hiroko; Nishizawa, Atsushi J.; Obuchi, Yoshiyuki; Oguri, Masamune; Oishi, Yukie; Okabe, Nobuhiro; Okamoto, Sakurako; Okura, Yuki; Ono, Yoshiaki; Onodera, Masato; Onoue, Masafusa; Osato, Ken; Ouchi, Masami; Price, Paul A.; Pyo, Tae-Soo; Sako, Masao; Sawicki, Marcin; Shibuya, Takatoshi; Shimasaku, Kazuhiro; Shimono, Atsushi; Shirasaki, Masato; Silverman, John D.; Simet, Melanie; Speagle, Joshua; Spergel, David N.; Strauss, Michael A.; Sugahara, Yuma; Sugiyama, Naoshi; Suto, Yasushi; Suyu, Sherry H.; Suzuki, Nao; Tait, Philip J.; Takada, Masahiro; Takata, Tadafumi; Tamura, Naoyuki; Tanaka, Manobu M.; Tanaka, Masaomi; Tanaka, Masayuki; Tanaka, Yoko; Terai, Tsuyoshi; Terashima, Yuichi; Toba, Yoshiki; Tominaga, Nozomu; Toshikawa, Jun; Turner, Edwin L.; Uchida, Tomohisa; Uchiyama, Hisakazu; Umetsu, Keiichi; Uraguchi, Fumihiro; Urata, Yuji; Usuda, Tomonori; Utsumi, Yousuke; Wang, Shiang-Yu; Wang, Wei-Hao; Wong, Kenneth C.; Yabe, Kiyoto; Yamada, Yoshihiko; Yamanoi, Hitomi; Yasuda, Naoki; Yeh, Sherry; Yonehara, Atsunori; Yuma, Suraphong

    2018-01-01

    Hyper Suprime-Cam (HSC) is a wide-field imaging camera on the prime focus of the 8.2-m Subaru telescope on the summit of Mauna Kea in Hawaii. A team of scientists from Japan, Taiwan, and Princeton University is using HSC to carry out a 300-night multi-band imaging survey of the high-latitude sky. The survey includes three layers: the Wide layer will cover 1400 deg2 in five broad bands (grizy), with a 5 σ point-source depth of r ≈ 26. The Deep layer covers a total of 26 deg2 in four fields, going roughly a magnitude fainter, while the UltraDeep layer goes almost a magnitude fainter still in two pointings of HSC (a total of 3.5 deg2). Here we describe the instrument, the science goals of the survey, and the survey strategy and data processing. This paper serves as an introduction to a special issue of the Publications of the Astronomical Society of Japan, which includes a large number of technical and scientific papers describing results from the early phases of this survey.

  14. Quasiparticle self-consistent GW method: a short summary

    International Nuclear Information System (INIS)

    Kotani, Takao; Schilfgaarde, Mark van; Faleev, Sergey V; Chantis, Athanasios

    2007-01-01

    We have developed a quasiparticle self-consistent GW method (QSGW), which is a new self-consistent method to calculate the electronic structure within the GW approximation. The method is formulated based on the idea of a self-consistent perturbation; the non-interacting Green function G 0 , which is the starting point for GWA to obtain G, is determined self-consistently so as to minimize the perturbative correction generated by GWA. After self-consistency is attained, we have G 0 , W (the screened Coulomb interaction) and G self-consistently. This G 0 can be interpreted as the optimum non-interacting propagator for the quasiparticles. We will summarize some theoretical discussions to justify QSGW. Then we will survey results which have been obtained up to now: e.g., band gaps for normal semiconductors are predicted to a precision of 0.1-0.3 eV; the self-consistency including the off-diagonal part is required for NiO and MnO; and so on. There are still some remaining disagreements with experiments; however, they are very systematic, and can be explained from the neglect of excitonic effects

  15. Double-theodolite measurement system used in the image calibration of space photographic instrument

    Institute of Scientific and Technical Information of China (English)

    LI Yan; QIAO Yan-feng; SU Wan-xin; LIU Ze-xun

    2005-01-01

    The purpose of characterizing the image of space photographic instrument is to gain the space included angles from three coordinate axes in the three-dimensional coordinate of the image and the directionality of the three axes of coordinate in the frame of axes of the instrument. The two reference frames will keep in the same direction finally by adjusting according to space angles. This problem was solved by a new high-precision measurement system composed of a double-theodolite and a set of communication system. In the survey system, two TDA5005 total stations from Leica Company will be selected as the double-theodolite and the interdependence of both coordinate systems can be achieved by moving the stations only at one time. Therefore, this measurement system provides a highly efficient and high-precision surveying method to the image calibration of the space photographic instrument. According to the experiment, its measuring accuracy can reach arc-second level.

  16. Psychological ownership: Development of an instrument

    Directory of Open Access Journals (Sweden)

    Chantal Olckers

    2013-10-01

    Purpose: The purpose of this study was to develop an instrument to measure psychological ownership in a South African context. Motivation for the study: It was found that previous instruments for the measurement of psychological ownership lacked the ability to grasp the extensive reach of psychological ownership. Research design, approach and method: A quantitative cross-sectional survey was conducted on a non-probability convenience sample of 713 skilled, highly-skilled and professional employees from various organisations in both the private and public sectors in South Africa. Main findings: Although a 69-item measurement instrument was developed in order to capture the proposed seven-dimensional psychological ownership construct, it became evident when analysing the data that a four-factor model comprising 35 items was suitable. Practical/managerial implications: If a sense of psychological ownership toward an organisation could be established amongst its employees by addressing the factors as measured by the South African Psychological Ownership Questionnaire, organisations could become enhanced workplaces and, as a result, sustainable performance could be promoted and staff could be retained. Contribution/value-add: The instrument for measuring psychological ownership in a South African context could serve as a diagnostic tool that would allow human resource professionals and managers to determine employees’ sense of psychological ownership regarding their organisation and to focus specifically on weak dimensional areas that could be improved.

  17. Indexing contamination surveys

    International Nuclear Information System (INIS)

    Brown, R.L.

    1998-01-01

    The responsibility for safely managing the Tank Farms at Hanford belongs to Lockheed Martin Hanford Corporation which is part of the six company Project Hanford Management Team led by Fluor Daniel Hanford, Inc.. These Tank Farm Facilities contain numerous outdoor contamination areas which are surveyed at a periodicity consistent with the potential radiological conditions, occupancy, and risk of changes in radiological conditions. This document describes the survey documentation and data tracking method devised to track the results of contamination surveys this process is referred to as indexing. The indexing process takes a representative data set as an indicator for the contamination status of the facility. The data are further manipulated into a single value that can be tracked and trended using standard statistical methodology. To report meaningful data, the routine contamination surveys must be performed in a manner that allows the survey method and the data collection process to be recreated. Three key criteria are necessary to accomplish this goal: Accurate maps, consistent documentation, and consistent consolidation of data meeting these criteria provides data of sufficient quality to be tracked. Tracking of survey data is accomplished by converting the individual survey results into a weighted value, corrected for the actual number of survey points. This information can be compared over time using standard statistical analysis to identify trends. At the Tank Farms, the need to track and trend the facility's radiological status presents unique challenges. Many of these Tank Farm facilities date back to the second world war. The Tank Farm Facilities are exposed to weather extremes, plant and animal intrusion, as well as all of the normal challenges associated with handling radiological waste streams. Routine radiological surveys did not provide a radiological status adequate for continuing comparisons

  18. Development and evaluation of a new survey instrument to measure the quality of colorectal cancer screening decisions.

    Science.gov (United States)

    Sepucha, Karen R; Feibelmann, Sandra; Cosenza, Carol; Levin, Carrie A; Pignone, Michael

    2014-08-20

    Guidelines for colorectal cancer screening recommend that patients be informed about options and be able to select preferred method of screening; however, there are no existing measures available to assess whether this happens. Colorectal Cancer Screening Decision Quality Instrument (CRC-DQI) includes knowledge items and patients' goals and concerns. Items were generated through literature review and qualitative work with patients and providers. Hypotheses relating to the acceptability, feasibility, discriminant validity and retest reliability of the survey were examined using data from three studies: (1) 2X2 randomized study of participants recruited online, (2) cross-sectional sample of patients recruited in community health clinics, and (3) cross-sectional sample of providers recruited from American Medical Association Master file. 338 participants were recruited online, 94 participants were recruited from community health centers, and 115 physicians were recruited. The CRC-DQI was feasible and acceptable with low missing data and high response rates for both online and paper-based administrations. The knowledge score was able to discriminate between those who had seen a decision aid or not (84% vs. 64%, p quality decisions about colon cancer screening.

  19. Analysis and protective measures of sharp instrument injury causes of sterilization and supply center

    Directory of Open Access Journals (Sweden)

    Hua YANG

    2014-11-01

    Full Text Available Objective: To analyze the causes of sharp injury in the sterilization and supply center, take protective measures, effectively avoid sharp instrument injury, and guarantee staff safety. Methods: Adopt a retrospective survey method, summarize sharp instrument injury data of sterilization and supply center in 2013, analyze the reasons of the occurrence of sharp instrument injury, and make protective countermeasures. Results: Sharp instrument injuries occurred mainly in the device classification, manual cleaning and device packaging process. Conclusion: Poor consciousness of occupational protection of the staff in the sterilization and supply center, nonstandard operation, and lack of training and supervision in place are the main reasons of occurrence of sharp instrument injury.

  20. Developing of Individual Instrument Performance Anxiety Scale: ValidityReliability Study

    Directory of Open Access Journals (Sweden)

    Esra DALKIRAN

    2016-07-01

    Full Text Available In this study, it is intended to develop a scale unique to our culture, concerning individual instrument performance anxiety of the students who are getting instrument training in the Department of Music Education. In the study, the descriptive research model is used and qualitative research techniques are utilized. The study population consists of the students attending the 23 universities which has Music Education Department. The sample of the study consists of 438 girls and 312 boys, totally 750 students who are studying in the Department of Music Education of randomly selected 10 universities. As a result of the explanatory and confirmatory factor analyses that were performed, a onedimensional structure consisting of 14 items was obtained. Also, t-scores and the coefficient scores of total item correlation concerning the distinguishing power of the items, the difference in the scores of the set of lower and upper 27% was calculated, and it was observed that the items are distinguishing as a result of both analyses. Of the scale, Cronbach's alpha coefficient of internal consistency was calculated as .94, and test-retest reliability coefficient was calculated as .93. As a result, a valid and reliable assessment and evaluation instrument that measures the exam performance anxiety of the students studying in the Department of Music Education, has been developed.

  1. 36 CFR 223.218 - Consistency with plans, environmental standards, and other management requirements.

    Science.gov (United States)

    2010-07-01

    ..., environmental standards, and other management requirements. 223.218 Section 223.218 Parks, Forests, and Public... Special Forest Products § 223.218 Consistency with plans, environmental standards, and other management... with applicable land management plans. Each contract, permit, or other authorizing instrument shall...

  2. Validation of a survey instrument to assess home environments for physical activity and healthy eating in overweight children

    Directory of Open Access Journals (Sweden)

    Crane Lori A

    2008-01-01

    Full Text Available Abstract Background Few measures exist to measure the overall home environment for its ability to support physical activity (PA and healthy eating in overweight children. The purpose of this study was to develop and test the reliability and validity of such a measure. Methods The Home Environment Survey (HES was developed to reflect availability, accessibility, parental role modelling, and parental policies related to PA resources, fruits and vegetables (F&V, and sugar sweetened drinks and snacks (SS. Parents of overweight children (n = 219 completed the HES and concurrent behavioural assessments. Children completed the Block Kids survey and wore an accelerometer for one week. A subset of parents (n = 156 completed the HES a second time to determine test-retest reliability. Finally, 41 parent dyads living in the same home (n = 41 completed the survey to determine inter-rater reliability. Initial psychometric analyses were completed to trim items from the measure based on lack of variability in responses, moderate or higher item to scale correlation, or contribution to strong internal consistency. Inter-rater and test-retest reliability were completed using intraclass correlation coefficients. Validity was assessed using Pearson correlations between the HES scores and child and parent nutrition and PA. Results Eight items were removed and acceptable internal consistency was documented for all scales (α = .66–84 with the exception of the F&V accessibility. The F&V accessibility was reduced to a single item because the other two items did not meet reliability standards. Test-retest reliability was high (r > .75 for all scales. Inter-rater reliability varied across scales (r = .22–.89. PA accessibility, parent role modelling, and parental policies were all related significantly to child (r = .14–.21 and parent (r = .15–.31 PA. Similarly, availability of F&V and SS, parental role modelling, and parental policies were related to child (r

  3. Development of an instrument for community-level health related social capital among Japanese older people: The JAGES Project.

    Science.gov (United States)

    Saito, Masashige; Kondo, Naoki; Aida, Jun; Kawachi, Ichiro; Koyama, Shihoko; Ojima, Toshiyuki; Kondo, Katsunori

    2017-05-01

    We developed and validated an instrument to measure community-level social capital based on data derived from older community dwellers in Japan. We used cross-sectional data from the Japan Gerontological Evaluation Study, a nationwide survey involving 123,760 functionally independent older people nested within 702 communities (i.e., school districts). We conducted exploratory and confirmatory factor analyses on survey items to determine the items in a multi-dimensional scale to measure community social capital. Internal consistency was checked with Cronbach's alpha. Convergent construct validity was assessed via correlating the scale with health outcomes. From 53 candidate variables, 11 community-level variables were extracted: participation in volunteer groups, sports groups, hobby activities, study or cultural groups, and activities for teaching specific skills; trust, norms of reciprocity, and attachment to one's community; received emotional support; provided emotional support; and received instrumental support. Using factor analysis, these variables were determined to belong to three sub-scales: civic participation (eigenvalue = 3.317, α = 0.797), social cohesion (eigenvalue = 2.633, α = 0.853), and reciprocity (eigenvalue = 1.424, α = 0.732). Confirmatory factor analysis indicated the goodness of fit of this model. Multilevel Poisson regression analysis revealed that civic participation score was robustly associated with individual subjective health (Self-Rated Health: prevalence ratio [PR] 0.96; 95% confidence interval [CI], 0.94-0.98; Geriatric Depression Scale [GDS]: PR 0.95; 95% CI, 0.93-0.97). Reciprocity score was also associated with individual GDS (PR 0.98; 95% CI, 0.96-1.00). Social cohesion score was not consistently associated with individual health indicators. Our scale for measuring social capital at the community level might be useful for future studies of older community dwellers. Copyright © 2016 The Authors. Production and

  4. Development of an instrument for community-level health related social capital among Japanese older people: The JAGES Project

    Directory of Open Access Journals (Sweden)

    Masashige Saito

    2017-05-01

    Full Text Available Background: We developed and validated an instrument to measure community-level social capital based on data derived from older community dwellers in Japan. Methods: We used cross-sectional data from the Japan Gerontological Evaluation Study, a nationwide survey involving 123,760 functionally independent older people nested within 702 communities (i.e., school districts. We conducted exploratory and confirmatory factor analyses on survey items to determine the items in a multi-dimensional scale to measure community social capital. Internal consistency was checked with Cronbach's alpha. Convergent construct validity was assessed via correlating the scale with health outcomes. Results: From 53 candidate variables, 11 community-level variables were extracted: participation in volunteer groups, sports groups, hobby activities, study or cultural groups, and activities for teaching specific skills; trust, norms of reciprocity, and attachment to one's community; received emotional support; provided emotional support; and received instrumental support. Using factor analysis, these variables were determined to belong to three sub-scales: civic participation (eigenvalue = 3.317, α = 0.797, social cohesion (eigenvalue = 2.633, α = 0.853, and reciprocity (eigenvalue = 1.424, α = 0.732. Confirmatory factor analysis indicated the goodness of fit of this model. Multilevel Poisson regression analysis revealed that civic participation score was robustly associated with individual subjective health (Self-Rated Health: prevalence ratio [PR] 0.96; 95% confidence interval [CI], 0.94–0.98; Geriatric Depression Scale [GDS]: PR 0.95; 95% CI, 0.93–0.97. Reciprocity score was also associated with individual GDS (PR 0.98; 95% CI, 0.96–1.00. Social cohesion score was not consistently associated with individual health indicators. Conclusions: Our scale for measuring social capital at the community level might be useful for future studies of older community dwellers.

  5. Real-time instrument-failure detection in the LOFT pressurizer using functional redundancy

    International Nuclear Information System (INIS)

    Tylee, J.L.

    1982-07-01

    The functional redundancy approach to detecting instrument failures in a pressurized water reactor (PWR) pressurizer is described and evaluated. This real-time method uses a bank of Kalman filters (one for each instrument) to generate optimal estimates of the pressurizer state. By performing consistency checks between the output of each filter, failed instruments can be identified. Simulation results and actual pressurizer data are used to demonstrate the capabilities of the technique

  6. Development of the Human Factors Skills for Healthcare Instrument: a valid and reliable tool for assessing interprofessional learning across healthcare practice settings.

    Science.gov (United States)

    Reedy, Gabriel B; Lavelle, Mary; Simpson, Thomas; Anderson, Janet E

    2017-10-01

    A central feature of clinical simulation training is human factors skills, providing staff with the social and cognitive skills to cope with demanding clinical situations. Although these skills are critical to safe patient care, assessing their learning is challenging. This study aimed to develop, pilot and evaluate a valid and reliable structured instrument to assess human factors skills, which can be used pre- and post-simulation training, and is relevant across a range of healthcare professions. Through consultation with a multi-professional expert group, we developed and piloted a 39-item survey with 272 healthcare professionals attending training courses across two large simulation centres in London, one specialising in acute care and one in mental health, both serving healthcare professionals working across acute and community settings. Following psychometric evaluation, the final 12-item instrument was evaluated with a second sample of 711 trainees. Exploratory factor analysis revealed a 12-item, one-factor solution with good internal consistency (α=0.92). The instrument had discriminant validity, with newly qualified trainees scoring significantly lower than experienced trainees ( t (98)=4.88, pSkills for Healthcare Instrument provides a reliable and valid method of assessing trainees' human factors skills self-efficacy across acute and mental health settings. This instrument has the potential to improve the assessment and evaluation of human factors skills learning in both uniprofessional and interprofessional clinical simulation training.

  7. The Job Training and Job Satisfaction Survey Technical Manual

    Science.gov (United States)

    Schmidt, Steven W.

    2004-01-01

    Job training has become an important aspect of an employee's overall job experience. However, it is not often called out specifically on instruments measuring job satisfaction. This technical manual details the processes used in the development and validation of a survey instrument to measure job training satisfaction and overall job…

  8. Content validation: clarity/relevance, reliability and internal consistency of enunciative signs of language acquisition.

    Science.gov (United States)

    Crestani, Anelise Henrich; Moraes, Anaelena Bragança de; Souza, Ana Paula Ramos de

    2017-08-10

    To analyze the results of the validation of building enunciative signs of language acquisition for children aged 3 to 12 months. The signs were built based on mechanisms of language acquisition in an enunciative perspective and on clinical experience with language disorders. The signs were submitted to judgment of clarity and relevance by a sample of six experts, doctors in linguistic in with knowledge of psycholinguistics and language clinic. In the validation of reliability, two judges/evaluators helped to implement the instruments in videos of 20% of the total sample of mother-infant dyads using the inter-evaluator method. The method known as internal consistency was applied to the total sample, which consisted of 94 mother-infant dyads to the contents of the Phase 1 (3-6 months) and 61 mother-infant dyads to the contents of Phase 2 (7 to 12 months). The data were collected through the analysis of mother-infant interaction based on filming of dyads and application of the parameters to be validated according to the child's age. Data were organized in a spreadsheet and then converted to computer applications for statistical analysis. The judgments of clarity/relevance indicated no modifications to be made in the instruments. The reliability test showed an almost perfect agreement between judges (0.8 ≤ Kappa ≥ 1.0); only the item 2 of Phase 1 showed substantial agreement (0.6 ≤ Kappa ≥ 0.79). The internal consistency for Phase 1 had alpha = 0.84, and Phase 2, alpha = 0.74. This demonstrates the reliability of the instruments. The results suggest adequacy as to content validity of the instruments created for both age groups, demonstrating the relevance of the content of enunciative signs of language acquisition.

  9. Structural Consistency, Consistency, and Sequential Rationality.

    OpenAIRE

    Kreps, David M; Ramey, Garey

    1987-01-01

    Sequential equilibria comprise consistent beliefs and a sequentially ra tional strategy profile. Consistent beliefs are limits of Bayes ratio nal beliefs for sequences of strategies that approach the equilibrium strategy. Beliefs are structurally consistent if they are rationaliz ed by some single conjecture concerning opponents' strategies. Consis tent beliefs are not necessarily structurally consistent, notwithstan ding a claim by Kreps and Robert Wilson (1982). Moreover, the spirit of stru...

  10. Consistency of performance of robot-assisted surgical tasks in virtual reality.

    Science.gov (United States)

    Suh, I H; Siu, K-C; Mukherjee, M; Monk, E; Oleynikov, D; Stergiou, N

    2009-01-01

    The purpose of this study was to investigate consistency of performance of robot-assisted surgical tasks in a virtual reality environment. Eight subjects performed two surgical tasks, bimanual carrying and needle passing, with both the da Vinci surgical robot and a virtual reality equivalent environment. Nonlinear analysis was utilized to evaluate consistency of performance by calculating the regularity and the amount of divergence in the movement trajectories of the surgical instrument tips. Our results revealed that movement patterns for both training tasks were statistically similar between the two environments. Consistency of performance as measured by nonlinear analysis could be an appropriate methodology to evaluate the complexity of the training tasks between actual and virtual environments and assist in developing better surgical training programs.

  11. Virtual Sensor Test Instrumentation

    Science.gov (United States)

    Wang, Roy

    2011-01-01

    Virtual Sensor Test Instrumentation is based on the concept of smart sensor technology for testing with intelligence needed to perform sell-diagnosis of health, and to participate in a hierarchy of health determination at sensor, process, and system levels. A virtual sensor test instrumentation consists of five elements: (1) a common sensor interface, (2) microprocessor, (3) wireless interface, (4) signal conditioning and ADC/DAC (analog-to-digital conversion/ digital-to-analog conversion), and (5) onboard EEPROM (electrically erasable programmable read-only memory) for metadata storage and executable software to create powerful, scalable, reconfigurable, and reliable embedded and distributed test instruments. In order to maximize the efficient data conversion through the smart sensor node, plug-and-play functionality is required to interface with traditional sensors to enhance their identity and capabilities for data processing and communications. Virtual sensor test instrumentation can be accessible wirelessly via a Network Capable Application Processor (NCAP) or a Smart Transducer Interlace Module (STIM) that may be managed under real-time rule engines for mission-critical applications. The transducer senses the physical quantity being measured and converts it into an electrical signal. The signal is fed to an A/D converter, and is ready for use by the processor to execute functional transformation based on the sensor characteristics stored in a Transducer Electronic Data Sheet (TEDS). Virtual sensor test instrumentation is built upon an open-system architecture with standardized protocol modules/stacks to interface with industry standards and commonly used software. One major benefit for deploying the virtual sensor test instrumentation is the ability, through a plug-and-play common interface, to convert raw sensor data in either analog or digital form, to an IEEE 1451 standard-based smart sensor, which has instructions to program sensors for a wide variety of

  12. Cross-cultural equivalence of the organisational culture survey in Australia

    Directory of Open Access Journals (Sweden)

    R. Erwee

    2001-09-01

    Full Text Available The aim of this study is to assess whether the cross-cultural equivalence of the Organisational Culture Survey (OCS persist in an Australian context. The nature of the instrument is presented which includes a clear statement of its South African origin and its’ place within a logical positivist paradigm. The sample consisted of 326 respondents from a population of managers of the Australian Institute of Management. This study confirms the instrument’s validity and internal consistency within an Australian context, but that further research is required into the functional and conceptual equivalence of the survey items and dimensions underpinning the items to conclusively establish its utility. Finally, aspects of the ‘organisational culture’ construct underlying the survey need revision given recent trends in related systems, complexity and chaos theories. Opsomming Technikons propageer die beoefening van ko˛peratiewe onderwys,’n opvoedkundige strategiewat leer deur produktiewewerkservaring integreermet die teoretiese kurrikulum. ByTechnikon SAegter, het slegs sowat 35% van die formele programme ’n verpligte leerervarings komponent.Teoretiese-begrondings navorsingsmetodologie is gebruik omsekere basiese veronderstellings van akademiese personeel te bepaal. Eerder as om’n spesifieke navorsingsprobleemas vertrekpunt te gebruik, ondersoek teoretiese-begronding’n areavan belang en laat die metodiek die relevante sake toe omte voorskyn te kom. Semi-gestruktureerde onderhoude,met vier ope vrae, is gevoer met ’n gestratifiseerde eweskansige steekproef van 25 akademiese personeellede vanTechnikon SA. Daar is bevind dat alhoewel daar beperkte oortuiging en gewillige uitlewing van kooperatiewe onderwys is, is dit nie beduidend as kenmerkend van die organisasie kultuur vanTechnikon SA nie.

  13. Diagnosing paratonia in the demented elderly: reliability and validity of the Paratonia Assessment Instrument (PAI).

    Science.gov (United States)

    Hobbelen, Johannes S M; Koopmans, Raymond T C M; Verhey, Frans R J; Habraken, Kitty M; de Bie, Rob A

    2008-08-01

    Paratonia is one of the associated movement disorders characteristic of dementia. The aim of this study was to develop an assessment tool (the Paratonia Assessment Instrument, PAI), based on the new consensus definition of paratonia. An additional aim was to investigate the reliability and validity of the PAI. A three-phase cross-sectional survey was conducted. In the first two phases, the PAI was developed and validated. In the third phase, the inter-observer reliability and feasibility of the instrument was tested. The original PAI consisted of five criteria that all needed to be met in order to make the diagnosis. On the basis of a qualitative analysis, one criterion was reformulated and another was removed. Following this, inter-observer reliability between the two assessors resulted in an improvement of Cohen's kappa from 0.532 in the initial phase to 0.677 in the second phase. This improvement was substantiated in the third phase by two independent assessors with Cohen's kappa ranging from 0.625 to 1. The PAI is a reliable and valid assessment tool for diagnosing paratonia in elderly people with dementia that can be applied easily in daily practice.

  14. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. An inspector-instrument interface design that allows communication of procedures, responses, and results between the instrument and user is presented. This capability has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  15. Inspector-instrument interface in portable NDA instrumentation

    International Nuclear Information System (INIS)

    Halbig, J.K.; Klosterbuer, S.F.

    1981-01-01

    Recent electronics technology advances make it possible to design sophisticated instruments in small packages for convenient field implementation. This report describes an inspector-instrument interface design which allows communication of procedures, responses, and results between the instrument and user. The interface has been incorporated into new spent-fuel instrumentation and a battery-powered multichannel analyzer

  16. Investigation of four self-report instruments (FABT, TSK-HC, Back-PAQ, HC-PAIRS) to measure healthcare practitioners' attitudes and beliefs toward low back pain: Reliability, convergent validity and survey of New Zealand osteopaths and manipulative physiotherapists.

    Science.gov (United States)

    Moran, Robert W; Rushworth, Wendy M; Mason, Jesse

    2017-12-01

    Healthcare practitioner beliefs influence advice and management provided to patients with back pain. Several instruments measuring practitioner beliefs have been developed but psychometric properties for some have not been investigated. To investigate internal consistency, test-retest reliability and convergent validity of the Fear Avoidance Beliefs Tool (FABT), the Tampa Scale of Kinesiophobia for Health Care Providers (TSK-HC), the Back Pain Attitudes Questionnaire (Back-PAQ), and the Health Care Pain and Impairment Relationship Scale (HC-PAIRS). A secondary aim was to explore beliefs of New Zealand osteopaths and physiotherapists regarding low back pain. FABT, TSK-HC, Back-PAQ, and HC-PAIRS were administered twice, 14 days apart. Data from 91 osteopaths and 35 physiotherapists were analysed. The FABT, TSK-HC and Back-PAQ each demonstrated excellent internal consistency, (Cronbach's α = 0.92, 0.91, and 0.91 respectively), and excellent test-retest reliability (lower limit of 95% CI for intraclass correlation coefficient >0.75). Correlations between instruments (Pearson's r = 0.51 to 0.77, p  0.47) for mean differences in scores, for all instruments, between professions. This study found excellent internal consistency, test-retest reliability and good convergent validity for the FABT, TSK-HC, and Back-PAQ. Previously reported internal consistency, test-retest and convergent validity of the HC-PAIRS were confirmed, and test-retest reliability was excellent. There were significant scoring differences on each instrument between professions, and while both groups demonstrated fear avoidant beliefs, physiotherapist respondent scores indicated that as a group, they held fewer fear-avoidant beliefs than osteopath respondents. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. The EyeHarp: A Gaze-Controlled Digital Musical Instrument.

    Science.gov (United States)

    Vamvakousis, Zacharias; Ramirez, Rafael

    2016-01-01

    We present and evaluate the EyeHarp, a new gaze-controlled Digital Musical Instrument, which aims to enable people with severe motor disabilities to learn, perform, and compose music using only their gaze as control mechanism. It consists of (1) a step-sequencer layer, which serves for constructing chords/arpeggios, and (2) a melody layer, for playing melodies and changing the chords/arpeggios. We have conducted a pilot evaluation of the EyeHarp involving 39 participants with no disabilities from both a performer and an audience perspective. In the first case, eight people with normal vision and no motor disability participated in a music-playing session in which both quantitative and qualitative data were collected. In the second case 31 people qualitatively evaluated the EyeHarp in a concert setting consisting of two parts: a solo performance part, and an ensemble (EyeHarp, two guitars, and flute) performance part. The obtained results indicate that, similarly to traditional music instruments, the proposed digital musical instrument has a steep learning curve, and allows to produce expressive performances both from the performer and audience perspective.

  18. Advances in constant-velocity Moessbauer instrumentation

    International Nuclear Information System (INIS)

    Veiga, A.; Martinez, N.; Zelis, P. Mendoza; Pasquevich, G. A.; Sanchez, F. H.

    2006-01-01

    A prototype of a programmable constant-velocity scaler is presented. This instrument allows the acquisition of partial Moessbauer spectra in selected energy regions using standard drivers and transducers. It can be fully operated by a remote application, thus data acquisition can be automated. The instrument consists of a programmable counter and a constant-velocity reference. The reference waveform generator is amplitude modulated with 13-bit resolution, and is programmable in a wide range of frequencies and waveforms in order to optimize the performance of the transducer. The counter is compatible with most standard SCA, and is configured as a rate-meter that provides counts per selectable time slice at the programmed velocity. As a demonstration of the instrument applications, a partial Moessbauer spectrum of a natural iron foil was taken. Only positive energies were studied in 512 channels, accumulating 20 s per channel. A line width of 0.20 mm/s was achieved, performing with an efficiency of 80%.

  19. The Survey of Treatment Entry Pressures (STEP): identifying client's reasons for entering substance abuse treatment.

    Science.gov (United States)

    Dugosh, Karen Leggett; Festinger, David S; Lynch, Kevin G; Marlowe, Douglas B

    2014-10-01

    Systematically identifying reasons that clients enter substance abuse treatment may allow clinicians to immediately focus on issues of greatest relevance to the individual and enhance treatment engagement. We developed the Survey of Treatment Entry Pressures (STEP) to identify the specific factors that precipitated an individual's treatment entry. The instrument contains 121 items from 6 psychosocial domains (i.e., family, financial, social, medical, psychiatric, legal). The current study examined the STEP's psychometric properties. A total of 761 participants from various treatment settings and modalities completed the STEP prior to treatment admission and 4-7 days later. Analyses were performed to examine the instrument's psychometric properties including item response rates, test-retest reliability, internal consistency, and factor structure. The items displayed adequate test-retest reliability and internal consistency within each psychosocial domain. Generally, results from exploratory and confirmatory factor analyses support a 2-factor structure reflecting type of reinforcement schedule. The study provides preliminary support for the psychometric properties of the STEP. The STEP may provide a reliable way for clinicians to characterize and capitalize on a client's treatment motivation early on which may serve to improve treatment retention and therapeutic outcomes. © 2014 Wiley Periodicals, Inc.

  20. Field measurements and interpretation of TMI-2 instrumentation: IC-10-dPT

    International Nuclear Information System (INIS)

    Jones, J.E.; Smith, J.T.; Mathis, M.V.

    1982-01-01

    This report describes the measurements and results of the Control Rod Drive Bypass Flow IC-10-dPT. This instrument consists of a Bailey Type BY Process Computer Transmitter connected to a readout module by approximately 500 feet of cable through a penetration junction and an instrument mounting junction. The status of this instrument is uncertain, but it was producing a reasonable output reading of zero flow which could indicate it had not failed. As a result, measurements on this instrument were designed to determine if it were properly functioning

  1. Instrument calls and real-time code for laboratory automation

    International Nuclear Information System (INIS)

    Taber, L.; Ames, H.S.; Yamauchi, R.K.; Barton, G.W. Jr.

    1978-01-01

    These programs are the result of a joint Lawrence Livermore Laboratory and Environmental Protection Agency project to automate water quality laboratories. They form the interface between the analytical instruments and the BASIC language programs for data reduction and analysis. They operate on Data General NOVA 840's at Cincinnati and Chicago and on a Data General ECLIPSE C330 at Livermore. The operating system consists of unmodified RDOS, Data General's disk operating system, and Data General's multiuser BASIC modified to provide the instrument CALLs and other functions described. Instruments automated at various laboratories include Technicon AutoAnalyzers, atomic absorption spectrophotometers, total organic carbon analyzers, an emission spectrometer, an electronic balance, sample changers, and an optical spectrophotometer. Other instruments may be automated using these same CALLs, or new CALLs may be written as described

  2. Linguistic Validation and Cultural Adaptation of Bulgarian Version of Hospital Survey on Patient Safety Culture (HSOPSC).

    Science.gov (United States)

    Stoyanova, Rumyana; Dimova, Rositsa; Tarnovska, Miglena; Boeva, Tatyana

    2018-05-20

    Patient safety (PS) is one of the essential elements of health care quality and a priority of healthcare systems in most countries. Thus the creation of validated instruments and the implementation of systems that measure patient safety are considered to be of great importance worldwide. The present paper aims to illustrate the process of linguistic validation, cross-cultural verification and adaptation of the Bulgarian version of the Hospital Survey on Patient Safety Culture (B-HSOPSC) and its test-retest reliability. The study design is cross-sectional. The HSOPSC questionnaire consists of 42 questions, grouped in 12 different subscales that measure patient safety culture. Internal con-sistency was assessed using Cronbach's alpha. The Wilcoxon signed-rank test and the split-half method were used; the Spear-man-Brown coefficient was calculated. The overall Cronbach's alpha for B-HSOPSC is 0.918. Subscales 7 Staffing and 12 Overall perceptions of safety had the lowest coefficients. The high reliability of the instrument was confirmed by the Split-half method (0.97) and ICC-coefficient (0.95). The lowest values of Spearmen-Broun coefficients were found in items A13 and A14. The study offers an analysis of the results of the linguistic validation of the B-HSOPSC and its test-retest reliability. The psychometric characteristics of the questions revealed good validity and reliability, except two questions. In the future, the instrument will be administered to the target population in the main study so that the psychometric properties of the instrument can be verified.

  3. The design and implementation of the Dynamic Ionosphere Cubesat Experiment (DICE) science instruments

    Science.gov (United States)

    Burr, Steven Reed

    Dynamic Ionosphere Cubesat Experiment (DICE) is a satellite project funded by the National Science Foundation (NSF) to study the ionosphere, more particularly Storm Enhanced Densities (SED) with a payload consisting of plasma diagnostic instrumentation. Three instruments onboard DICE include an Electric Field Probe (EFP), Ion Langmuir Probe (ILP), and Three Axis Magnetometer (TAM). The EFP measures electric fields from +/-8V and consists of three channels a DC to 40Hz channel, a Floating Potential Probe (FPP), and an spectrographic channel with four bands from 16Hz to 512Hz. The ILP measures plasma densities from 1x104 cm--3 to 2x107 cm--3. The TAM measures magnetic field strength with a range +/-0.5 Gauss with a sensitivity of 2nT. To achieve desired mission requirements careful selection of instrument requirements and planning of the instrumentation design to achieve mission success. The analog design of each instrument is described in addition to the digital framework required to sample the science data at a 70Hz rate and prepare the data for the Command and Data Handing (C&DH) system. Calibration results are also presented and show fulfillment of the mission and instrumentation requirements.

  4. Are Canadian clinicians providing consistent sport-related concussion management advice?

    Science.gov (United States)

    Carson, James D; Rendely, Alexandra; Garel, Alisha; Meaney, Christopher; Stoller, Jacqueline; Kaicker, Jatin; Hayden, Leigh; Moineddin, Rahim; Frémont, Pierre

    2016-06-01

    To compare the knowledge and use of recommendations for the management of sport-related concussion (SRC) among sport and exercise medicine physicians (SEMPs) and emergency department physicians (EDPs) to assess the success of SRC knowledge transfer across Canada. A self-administered, multiple-choice survey accessed via e-mail by SEMPs and EDPs. The survey had been assessed for content validity. Canada. The survey was completed between May and July 2012 by SEMPs who had passed the diploma examination of the Canadian Academy of Sport and Exercise Medicine and by EDPs who did not hold this diploma. Knowledge and identification of sources of concussion management information, use of concussion diagnosis strategies, and whether physicians use common and consistent terminology when explaining cognitive rest strategies to patients after an SRC. There was a response rate of 28% (305 of 1085). The SEMP and EDP response rates were 41% (147 of 360) and 22% (158 of 725), respectively. Of the responses, 41% of EDPs and 3% of SEMPs were unaware of any consensus statements on concussion in sport; 74% of SEMPs used the Sport Concussion Assessment Tool, version 2 (SCAT2), "usually or always," whereas 88% of EDPs never used the SCAT2. When queried about how cognitive rest could best be achieved after an SRC, no consistent answer was documented. Differences and a lack of consistency in the implementation of recommendations for SRC patients were identified for SEMPs and EDPs. It appears that the SCAT2 is used more in the SEMP setting than in the emergency context. Further knowledge transfer efforts and research should address the barriers to achieving more consistent advice given by physicians who attend SRC patients. Copyright© the College of Family Physicians of Canada.

  5. Progress in XRCS-Survey plant instrumentation and control design for ITER

    International Nuclear Information System (INIS)

    Varshney, Sanjeev; Jha, Shivakant; Simrock, Stefan; Barnsley, Robin; Martin, Vincent; Mishra, Sapna; Patil, Prabhakant; Patel, Shreyas; Kumar, Vinay

    2016-01-01

    Highlights: • An identification of the major process functions system compliant to Plant Control Design Handbook (PCDH) has been made for XRCS-Survey plant I&C. • I&C Functional Breakdown Structure (FBS) and Operation Procedure (OP) have been drafted using Enterprise architect (EA). • I&C architecture, interface with ITER networks and Plants, configuration of cubicles are discussed towards nine design review deliverables. - Abstract: A real time, plasma impurity survey system based on X-ray Crystal Spectroscopy (XRCS) has been designed for ITER and will be made available in the set of first plasma diagnostics for measuring impurity ion concentrations and their in-flux. For the purpose of developing a component level design of XRCS-Survey plant I&C system that is compliant to the rules and guidelines defined in the Plant Control Design Handbook (PCDH), firstly an identification of the major process functions has been made. The preliminary plant I&C Functional Breakdown Structure (FBS) and Operation Procedure (OP) have been drafted using a system engineering tool, Enterprise Architect (EA). Conceptual I&C architecture, interface with the ITER networks and other Plants have been discussed along with the basic configuration of I&C cubicles aiming towards nine I&C deliverables for the design review.

  6. Progress in XRCS-Survey plant instrumentation and control design for ITER

    Energy Technology Data Exchange (ETDEWEB)

    Varshney, Sanjeev, E-mail: sanjeev.varshney@iter-india.org [ITER-India, Institute for Plasma Research, Bhat, Gandhinagar, 382 428 (India); Jha, Shivakant [ITER-India, Institute for Plasma Research, Bhat, Gandhinagar, 382 428 (India); Simrock, Stefan; Barnsley, Robin; Martin, Vincent [ITER-Organization, Route de Vinon sur Verdon, CS 90 046, 13067 St. Paul-Lez-Durance, Cedex (France); Mishra, Sapna [ITER-India, Institute for Plasma Research, Bhat, Gandhinagar, 382 428 (India); Patil, Prabhakant [ITER-Organization, Route de Vinon sur Verdon, CS 90 046, 13067 St. Paul-Lez-Durance, Cedex (France); Patel, Shreyas; Kumar, Vinay [ITER-India, Institute for Plasma Research, Bhat, Gandhinagar, 382 428 (India)

    2016-11-15

    Highlights: • An identification of the major process functions system compliant to Plant Control Design Handbook (PCDH) has been made for XRCS-Survey plant I&C. • I&C Functional Breakdown Structure (FBS) and Operation Procedure (OP) have been drafted using Enterprise architect (EA). • I&C architecture, interface with ITER networks and Plants, configuration of cubicles are discussed towards nine design review deliverables. - Abstract: A real time, plasma impurity survey system based on X-ray Crystal Spectroscopy (XRCS) has been designed for ITER and will be made available in the set of first plasma diagnostics for measuring impurity ion concentrations and their in-flux. For the purpose of developing a component level design of XRCS-Survey plant I&C system that is compliant to the rules and guidelines defined in the Plant Control Design Handbook (PCDH), firstly an identification of the major process functions has been made. The preliminary plant I&C Functional Breakdown Structure (FBS) and Operation Procedure (OP) have been drafted using a system engineering tool, Enterprise Architect (EA). Conceptual I&C architecture, interface with the ITER networks and other Plants have been discussed along with the basic configuration of I&C cubicles aiming towards nine I&C deliverables for the design review.

  7. Instrument evaluation no. 11. ESI nuclear model 271 C contamination monitor

    CERN Document Server

    Burgess, P H

    1978-01-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to he carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the a...

  8. Instrument evaluation no. 17. Wallac automatic alarm dosimeter type RAD21

    CERN Document Server

    Burgess, P H

    1980-01-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the a...

  9. Probabilistic safety assessment for instrumentation and control systems in nuclear power plants. A literature survey

    International Nuclear Information System (INIS)

    Lu, Lixuan; Jiang, Jin

    2003-01-01

    Deregulation in electricity market will create a great deal of challenges for Nuclear Power Plants (NPP). To stay competitive, NPP will need to find new ways to reduce their operation costs. In NPP, Instrumentation and Control (I and C) systems play an important role in reducing the cost of producing electricity while maintaining and/or enhancing safety. Therefore, it is extremely important that one should manage the I and C systems more efficiently and economically. Meanwhile, obsolescence problem associated with I and C systems encouraged the usage of advanced digital techniques in I and C systems. Thus, new methodologies are needed to analyze the reliability and determine the maintenance strategy for the digital I and C systems. Probabilistic Safety Assessment (PSA) has been probed to be a promising method to deal with this issue. This paper provides a literature survey on the development of digital I and C systems in NPP, followed by a detailed review of PSA including its benefits, limitations and the future direction of its development. Most importantly, potential applications of PSA in various aspects of I and C systems are brought into perspective throughout the paper. Furthermore, the applicability of PSA in the regulation of safety-related I and C systems is demonstrated. Detailed information on PSA applications in 1) the resource allocation for I and C systems: 2) the determination of surveillance testing strategies; and 3) I and C system designs, is provided. (author)

  10. Robotic thin layer chromatography instrument for synthetic chemistry

    International Nuclear Information System (INIS)

    Corkan, L.A.; Lindsey, J.S.

    1990-01-01

    One of our long-term goals is to develop robotic workstations for automated synthetic chemistry. Toward that goal we have constructed a 2nd generation instrument for performing TLC analysis. TLC has important advantages (over HPLC and GC) in analysis of crude reaction samples and parallel sample development. The TLC instrument consist of four dedicated stations for (1) plate dispensing, (2) sample application, (3) plate development, and (4) plate densitometry. A robot is used to move plates among stations. The combination of fixed automation and robotics gives high sample throughout (up to 10 samples per hour). A second robot performs reaction chemistry and feeds samples to the TLC instrument, thus enabling TLC analysis at the same time as synthetic reactions proceed on the workstation

  11. Operational problems with radiation survey meters - The University and Accelerator perspectives

    International Nuclear Information System (INIS)

    McCall, R.C.

    1984-06-01

    This article describes problems encountered with commercial survey meters. The desired qualities of such instruments for use around accelerators are listed. Attempts to meet the accelerator monitoring needs by modifying commercial instruments and by in-house research and development are described

  12. Cavity-enhanced quantum-cascade laser-based instrument for carbon monoxide measurements.

    Science.gov (United States)

    Provencal, Robert; Gupta, Manish; Owano, Thomas G; Baer, Douglas S; Ricci, Kenneth N; O'Keefe, Anthony; Podolske, James R

    2005-11-01

    An autonomous instrument based on off-axis integrated cavity output spectroscopy has been developed and successfully deployed for measurements of carbon monoxide in the troposphere and tropopause onboard a NASA DC-8 aircraft. The instrument (Carbon Monoxide Gas Analyzer) consists of a measurement cell comprised of two high-reflectivity mirrors, a continuous-wave quantum-cascade laser, gas sampling system, control and data-acquisition electronics, and data-analysis software. CO measurements were determined from high-resolution CO absorption line shapes obtained by tuning the laser wavelength over the R(7) transition of the fundamental vibration band near 2172.8 cm(-1). The instrument reports CO mixing ratio (mole fraction) at a 1-Hz rate based on measured absorption, gas temperature, and pressure using Beer's Law. During several flights in May-June 2004 and January 2005 that reached altitudes of 41,000 ft (12.5 km), the instrument recorded CO values with a precision of 0.2 ppbv (1-s averaging time) and an accuracy limited by the reference CO gas cylinder (uncertainty < 1.0%). Despite moderate turbulence and measurements of particulate-laden airflows, the instrument operated consistently and did not require any maintenance, mirror cleaning, or optical realignment during the flights.

  13. Survey and alignment of the Fermilab recycler antiproton storage ring

    International Nuclear Information System (INIS)

    Arics, Babatunde O.O.

    1999-01-01

    In June of 1999 Fermilab commissioned a newly constructed antiproton storage ring, the 'Recycler Ring', in the Main Injector tunnel directly above the Main Injector beamline. The Recycler Ring is a fixed 8 GeV kinetic energy storage ring and is constructed of strontium ferrite permanent magnets. The 3319.4-meter-circumference Recycler Ring consists of 344 gradient magnets and 100 quadrupoles all of which are permanent magnets. This paper discusses the methods employed to survey and align these permanent magnets within the Recycler Ring with the specified accuracy. The Laser Tracker was the major instrument used for the final magnet alignment. The magnets were aligned along the Recycler Ring with a relative accuracy of ±0.25 mm. (author)

  14. Mandolin Family Instruments

    Science.gov (United States)

    Cohen, David J.; Rossing, Thomas D.

    The mandolin family of instruments consists of plucked chordophones, each having eight strings in four double courses. With the exception of the mandobass, the courses are tuned in intervals of fifths, as are the strings in violin family instruments. The soprano member of the family is the mandolin, tuned G3-D4-A4-E5. The alto member of the family is the mandola, tuned C3-G3-D4-A4. The mandola is usually referred to simply as the mandola in the USA, but is called the tenor mandola in Europe. The tenor member of the family is the octave mandolin, tuned G2-D3-A3-E4. It is referred to as the octave mandolin in the USA, and as the octave mandola in Europe. The baritone member of the family is the mandocello, or mandoloncello, tuned C2-G2-D3-A3. A variant of the mandocello not common in the USA is the five-course liuto moderno, or simply liuto, designed for solo repertoire. Its courses are tuned C2-G2-D3-A3-E4. A mandobass was also made by more than one manufacturer during the early twentieth century, though none are manufactured today. They were fretted instruments with single string courses tuned E1-A1-D2-G2. There are currently a few luthiers making piccolo mandolins, tuned C4-G4-D5-A5.

  15. Consistently low prevalence of syphilis among female sex workers in Jinan, China: findings from two consecutive respondent driven sampling surveys.

    Directory of Open Access Journals (Sweden)

    Meizhen Liao

    Full Text Available BACKGROUND: Routine surveillance using convenient sampling found low prevalence of HIV and syphilis among female sex workers in China. Two consecutive surveys using respondent driven sampling were conducted in 2008 and 2009 to examine the prevalence of HIV and syphilis among female sex workers in Jinan, China. METHODS: A face-to-face interview was conducted to collect demographic, behavioral and service utilization information using a structured questionnaire. Blood samples were drawn for serological tests of HIV-1 antibody and syphilis antibody. Respondent Driven Sampling Analysis Tool was used to generate population level estimates. RESULTS: In 2008 and in 2009, 363 and 432 subjects were recruited and surveyed respectively. Prevalence of syphilis was 2.8% in 2008 and 2.2% in 2009, while no HIV case was found in both years. Results are comparable to those from routine sentinel surveillance system in the city. Only 60.8% subjects in 2008 and 48.3% in 2009 reported a consistent condom use with clients during the past month. Over 50% subjects had not been covered by any HIV-related services in the past year, with only 15.6% subjects in 2008 and 13.1% in 2009 ever tested for HIV. CONCLUSIONS: Despite the low prevalence of syphilis and HIV, risk behaviors are common. Targeted interventions to promote the safe sex and utilization of existing intervention services are still needed to keep the epidemic from growing.

  16. Qualifying instrument for evaluation of food and nutritional care in hospital.

    Science.gov (United States)

    Díez García, R W; Souza, A A; Proença, R P C

    2012-01-01

    Establishing criteria for hospital nutrition care ensures that quality care is delivered to patients. The responsibility of the Hospital Food and Nutrition Service (HFNS) is not always well defined, despite efforts to establish guidelines for patient clinical nutrition practice. This study describes the elaboration of an Instrument for Evaluation of Food and Nutritional Care (IEFNC) aimed at directing the actions of the Hospital Food and Nutrition Service. This instrument was qualified by means of a comparative analysis of the categories related to hospital food and nutritional care, published in the literature. Elaboration of the IEFNC comprised the following stages: (a) a survey of databases and documents for selection of the categories to be used in nutrition care evaluation, (b) a study of the institutional procedures for nutrition practice at two Brazilian hospitals, in order to provide a description of the sequence of actions that should be taken by the HFNS as well as other services participating in nutrition care, (c) design of the IEFNC based on the categories published in the literature, adapted to the sequence of actions observed in the routines of the hospitals under study, (d) application of the questionnaire at two different hospitals that was mentioned in the item (b), in order to assess the time spent on its application, the difficulties in phrasing the questions, and the coverage of the instrument, and (e) finalization of the instrument. The IEFNC consists of 50 open and closed questions on two areas of food and nutritional care in hospital: inpatient nutritional care and food service quality. It deals with the characterization and structure of hospitals and their HFNS, the actions concerning the patients' nutritional evaluation and monitoring, the meal production system, and the hospital diets. "This questionnaire is a tool that can be seen as a portrait of the structure and characteristics of the HFNS and its performance in clinical and meal

  17. [Development of MEDUC-PG14 survey to assess postgraduate teaching in medical specialties].

    Science.gov (United States)

    Pizarro, Margarita; Solís, Nancy; Rojas, Viviana; Díaz, Luis Antonio; Padilla, Oslando; Letelier, Luz María; Aizman, Andrés; Sarfatis, Alberto; Olivos, Trinidad; Soza, Alejandro; Delfino, Alejandro; Latorre, Gonzalo; Ivanovic-Zuvic, Danisa; Hoyl, Trinidad; Bitran, Marcela; Arab, Juan Pablo; Riquelme, Arnoldo

    2015-08-01

    Feedback is one of the most important tools to improve teaching in medical education. To develop an instrument to assess the performance of clinical postgraduate teachers in medical specialties. A qualitative methodology consisting in interviews and focus-groups followed by a quantitative methodology to generate consensus, was employed. After generating the instrument, psychometric tests were performed to assess the construct validity (factor analysis) and reliability (Cronbach’s alpha). Experts in medical education, teachers and residents of a medical school participated in interviews and focus groups. With this information, 26 categories (79 items) were proposed and reduced to 14 items (Likert scale 1-5) by an expert’s Delphi panel, generating the MEDUC-PG14 survey, which was answered by 123 residents from different programs of medical specialties. Construct validity was carried out. Factor analysis showed three domains: Teaching and evaluation, respectful behavior towards patients and health care team, and providing feedback. The global score was 4.46 ± 0.94 (89% of the maximum). One teachers’ strength, as evaluated by their residents was “respectful behavior” with 4.85 ± 0.42 (97% of the maximum). “Providing feedback” obtained 4.09 ± 1.0 points (81.8% of the maximum). MEDUC-PG14 survey had a Cronbach’s alpha coefficient of 0.947. MEDUC-PG14 survey is a useful and reliable guide for teacher evaluation in medical specialty programs. Also provides feedback to improve educational skills of postgraduate clinical teachers.

  18. TCSP ER-2 LIGHTNING INSTRUMENT PACKAGE (LIP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The TCSP ER-2 Lightning Instrument Package (LIP) consists of 7 rotating vane type electric field sensors and a two channel conductivity probe along with a central...

  19. Uranium Mill Tailings Remedial Action Program. Partial radiological survey of Shiprock vicinity property SH14 Shiprock, New Mexico, October-November 1982

    International Nuclear Information System (INIS)

    Flynn, K.F.; Justus, A.L.; Sholeen, C.M.; Smith, W.H.; Wynveen, R.A.

    1984-06-01

    As part of a detailed radiological assessment of the vicinity properties at Shiprock, a comprehensive survey of the vicinity property designated as SH14 was initiated during October and November 1982. At the time of the survey, vicinity property SH14 consisted of about 20 acres of open lands to the northeast of, and directly across the San Juan River from, the upper tailings pile at Shiprock. The lands consisted of a sandy soil, sparsley covered with trees and other vegetation. The partial assessment activities included determination of surface radiation levels on about a 2-meter grid spacing through direct instrument surveys and analysis of a soil sample collected from the area. The partial radiological assessment indicated elevated levels of radioactivity at several general areas within the open lands. Radiochemical analyses of the soil sample collected from one of these areas indicated a radium concentration of 18 +- 2 pCi/g, which is in excess of the limit of 5 pCi/g above background, averaged over the first 15 cm of soil below the surface, as specified in the EPA Standard (40 CFR 192). Subsurface soil sampling was not conducted, and thus the vertical extent of the radiological contamination is not known. Further measurements required to completely determine and accurately report the radiological status of this vicinity property, including additional direct instrument surveys, collection and analyses of soil samples, and the establishment of a 200-ft grid system, were planned for the final phase of this assessment. However, that phase of the program was cancelled before these measurements were accomplished. The total extent of the radiological contamination of vicinity property SH14 is presently unknown. Nonetheless, since the surface soil contamination levels exceeded the limits specified in the EPA Standard, remedial action for this vicinity site should be considered

  20. Using Cognitive Interviews to Pilot an International Survey of Principal Preparation: A Western Australian Perspective

    Science.gov (United States)

    Wildy, Helen; Clarke, Simon

    2009-01-01

    This paper provides an example of the application of the cognitive interview, a qualitative tool for pre-testing a survey instrument to check its cognitive validity, that is, whether the items mean to respondents what they mean to the item designers. The instrument is the survey used in the final phase of the International Study of Principal…

  1. Measurement equivalence of the food related lifestyle instrument (FRL) in Ireland and Great Britain

    DEFF Research Database (Denmark)

    O´Sullivan, C.; Scholderer, Joachim; Cowan, Cathal

    2005-01-01

    The food-related lifestyle instrument (FRL) is tested for cross-cultural validity. Representative consumer samples from the UK 1998 ( N = 1000) and Ireland 2001 (N = 1024) are compared using multi-sample confirmatory factor analysis with structured means. The results suggest that, in all five FRL...... domains, the measurement characteristics of the survey instrument were completely invariant across the two cultures. No indication was found of any bias. Regarding future applications of the FRL, it can be concluded that the instrument has identical measurement characteristics when applied to consumer...

  2. Policy instruments to decrease the climate impact of housing, personal transport and food. Detailed instrument descriptions; Ohjauskeinoja asumisen, henkiloeliikenteen ja ruoan ilmastovaikutusten hillintaeaen. Yksityiskohtaiset ohjauskeinokuvaukset

    Energy Technology Data Exchange (ETDEWEB)

    Heiskanen, E.; Perrels, A.; Nissinen, A.; Berghaell, E.; Liesimaa, V.; Mattinen, M. (eds.)

    2012-03-15

    Reducing consumption volumes or introducing climate conscious consumption patterns can be efficient ways to mitigate climate change. Twenty existing policy instruments affecting the greenhouse gas emissions of housing, passenger traffic and food are described in this report of the KUILU-project. The policy instruments and the possibilities to develop effective instrument packages were discussed in two expert workshops, the results of which are presented in annexes of this report. There are already several policy instruments that target on housing and passenger traffic. Their differences in estimated emission reductions are large, which can ease the prioritization and selection of the instruments for further development. So far, only one policy instrument exists that aims to reduce the climate impacts of food choices, namely a Council of State Decision of Principle on Promoting Sustainability in Public Purchasing. However, it includes several measures that can be used to influence private companies and citizens, and thus it opens the field of policy instrument for mitigation of climate impacts of food. According to the expert survey, the most effective policy instrument involved in the analysis was building regulations, and the four most effective instruments after this were the following: gradated procurement tax of cars based on emissions, gradation of car tax, taxation of transport fuels, energy taxes of housing, and the effect of ecodesign directive on appliances. The effectiveness of policy instruments related to food was assessed to be on average level. The five least effective instruments were: EU energy label, voluntary energy experts, the tax of beverage packing, energy certificates, and subsidies for energy efficiency reparation in buildings. However, the expert opinions on the effectiveness of the policy instruments varied significantly. After this report, the KUILU project continued with an analysis of the policy instrument packages and with suggestions

  3. Policy instruments to decrease the climate impact of housing, personal transport and food. Detailed instrument descriptions; Ohjauskeinoja asumisen, henkiloeliikenteen ja ruoan ilmastovaikutusten hillintaeaen. Yksityiskohtaiset ohjauskeinokuvaukset

    Energy Technology Data Exchange (ETDEWEB)

    Heiskanen, E.; Perrels, A.; Nissinen, A.; Berghaell, E.; Liesmaa, V.; Mattinen, M. (eds.)

    2012-07-01

    Reducing consumption volumes or introducing climate conscious consumption patterns can be efficient ways to mitigate climate change. Twenty existing policy instruments affecting the greenhouse gas emissions of housing, passenger traffic and food are described in this report of the KUILU-project. The policy instruments and the possibilities to develop effective instrument packages were discussed in two expert workshops, the results of which are presented in annexes of this report. There are already several policy instruments that target on housing and passenger traffic. Their differences in estimated emission reductions are large, which can ease the prioritization and selection of the instruments for further development. So far, only one policy instrument exists that aims to reduce the climate impacts of food choices, namely a Council of State Decision of Principle on Promoting Sustainability in Public Purchasing. However, it includes several measures that can be used to influence private companies and citizens, and thus it opens the field of policy instrument for mitigation of climate impacts of food. According to the expert survey, the most effective policy instrument involved in the analysis was building regulations, and the four most effective instruments after this were the following: gradated procurement tax of cars based on emissions, gradation of car tax, taxation of transport fuels, energy taxes of housing, and the effect of ecodesign directive on appliances. The effectiveness of policy instruments related to food was assessed to be on average level. The five least effective instruments were: EU energy label, voluntary energy experts, the tax of beverage packing, energy certificates, and subsidies for energy efficiency reparation in buildings. However, the expert opinions on the effectiveness of the policy instruments varied significantly. After this report, the KUILU project continued with an analysis of the policy instrument packages and with suggestions

  4. The Next Generation Transit Survey (NGTS)

    Science.gov (United States)

    Wheatley, Peter J.; West, Richard G.; Goad, Michael R.; Jenkins, James S.; Pollacco, Don L.; Queloz, Didier; Rauer, Heike; Udry, Stéphane; Watson, Christopher A.; Chazelas, Bruno; Eigmüller, Philipp; Lambert, Gregory; Genolet, Ludovic; McCormac, James; Walker, Simon; Armstrong, David J.; Bayliss, Daniel; Bento, Joao; Bouchy, François; Burleigh, Matthew R.; Cabrera, Juan; Casewell, Sarah L.; Chaushev, Alexander; Chote, Paul; Csizmadia, Szilárd; Erikson, Anders; Faedi, Francesca; Foxell, Emma; Gänsicke, Boris T.; Gillen, Edward; Grange, Andrew; Günther, Maximilian N.; Hodgkin, Simon T.; Jackman, James; Jordán, Andrés; Louden, Tom; Metrailler, Lionel; Moyano, Maximiliano; Nielsen, Louise D.; Osborn, Hugh P.; Poppenhaeger, Katja; Raddi, Roberto; Raynard, Liam; Smith, Alexis M. S.; Soto, Maritza; Titz-Weider, Ruth

    2018-04-01

    We describe the Next Generation Transit Survey (NGTS), which is a ground-based project searching for transiting exoplanets orbiting bright stars. NGTS builds on the legacy of previous surveys, most notably WASP, and is designed to achieve higher photometric precision and hence find smaller planets than have previously been detected from the ground. It also operates in red light, maximizing sensitivity to late K and early M dwarf stars. The survey specifications call for photometric precision of 0.1 per cent in red light over an instantaneous field of view of 100 deg2, enabling the detection of Neptune-sized exoplanets around Sun-like stars and super-Earths around M dwarfs. The survey is carried out with a purpose-built facility at Cerro Paranal, Chile, which is the premier site of the European Southern Observatory (ESO). An array of twelve 20 cm f/2.8 telescopes fitted with back-illuminated deep-depletion CCD cameras is used to survey fields intensively at intermediate Galactic latitudes. The instrument is also ideally suited to ground-based photometric follow-up of exoplanet candidates from space telescopes such as TESS, Gaia and PLATO. We present observations that combine precise autoguiding and the superb observing conditions at Paranal to provide routine photometric precision of 0.1 per cent in 1 h for stars with I-band magnitudes brighter than 13. We describe the instrument and data analysis methods as well as the status of the survey, which achieved first light in 2015 and began full-survey operations in 2016. NGTS data will be made publicly available through the ESO archive.

  5. Developing an Instrument to Measure Autonomous Adaptive Capacity to Climate Change among Urban Households

    Directory of Open Access Journals (Sweden)

    Kathryn R. Selm

    2018-02-01

    Full Text Available The capacity of households in urban environments to adapt and react to climate change can affect the resilience of the whole community, and instruments for systematically measuring that capacity are needed. We used Raleigh, NC as a case study to explore the dimensions of autonomous adaptive capacity of urban households and to create a scale and associated survey instrument to measure them. Our approach was guided by four capitals that support human livelihoods: social, human, physical, and financial. We surveyed 200 households in Raleigh, NC, and used a principal components analysis to test the scale and survey instrument. Results suggest the scale is a useful and concise tool. Three major dimensions were present among the scale items: financial capital, political awareness, and access to resources. Together, these three dimensions can be used to measure adaptive capacity among different households. These findings are supported by similar work illustrating the value of income inequality and political awareness as indicators of adaptive capacity. Our results also demonstrate that complex relationships among the livelihood capitals may confound our ability to measure financial, physical, and human capitals separately. This framework for assessing adaptive capacity of households, with further refinement and testing, may be used in urban areas to evaluate programs designed to impact resilience to climate change.

  6. World Health Organization quality of life instrument-brief and Short Form-36 in patients with coronary artery disease: do they measure similar quality of life concepts?

    Science.gov (United States)

    Cruz, Luciane Nascimento; Camey, Suzi Alves; Fleck, Marcelo Pio; Polanczyk, Carisi Anne

    2009-10-01

    This study aimed to assess the validity and reliability of World Health Organization Quality of Life Instrument (WHOQOL)-brief and SF-36 in patients with coronary artery disease (CAD). Considering that depression is known to be associated with bad outcomes in CAD and it is highly associated with poor Quality of Life (QOL), we tested the correlation between WHOQOL and SF-36 and an instrument to screen depressive symptoms. It is a cross-sectional survey conducted in 103 patients with documented CAD. QOL was measured through WHOQOL-brief and SF-36 and depressive symptoms were assessed by the Beck Depression Inventory (BDI). To evaluate convergent validity, the correlations between both QOL assessment instruments were examined; discriminant validity was assessed through BDI and QOL instruments correlations. Coefficient Cronbach's alpha was used to test reliability. Percentages of floor and ceiling effects were higher in SF-36 scores than the WHOQOL-brief ones. Although WHOQOL-brief showed a maximum of 1% of floor effect and 9% of ceiling effect, SF-36 presented 40 and 32%, respectively. Internal consistency reliability ranged from 0.65 to 0.85 for the WHOQOL-brief and 0.57 to 0.89 for the SF-36. Correlations between subscales of WHOQOL-brief and BDI ranged from -0.74 to -0.61 and correlations between subscales of SF-36 and BDI ranged from -0.68 to -0.26. SF-36 and WHOQOL-brief seem to be valid and consistent QOL measures in patients with CAD. Researchers should define the aims of their studies before choosing which instrument to use, because they appear to measure different constructs of QOL.

  7. Practical considerations in developing an instrument-maintenance plan--

    International Nuclear Information System (INIS)

    Guth, M.A.S.

    1989-01-01

    The author develops a general set of considerations to explain how a consistent, well-organized, prioritized, and adequate time-allowance program plan for routine maintenance can be constructed. The analysis is supplemented with experience from the high flux isotope reactor (HFIR) at US Oak Ridge National Laboratory (ORNL). After the preventive maintenance (PM) problem was defined, the instruments on the schedule were selected based on the manufacturer's design specifications, quality-assurance requirements, prior classifications, experiences with the incidence of breakdowns or calibration, and dependencies among instruments. The effects of repair error in PM should be also studied. The HFIR requires three full-time technicians to perform both PM and unscheduled maintenance. A review is presented of concepts from queuing theory to determine anticipated breakdown patterns. In practice, the pneumatic instruments have a much longer lifetime than the electric/electronic instruments on various reactors at ORNL. Some special considerations and risk aversion in choosing a maintenance schedule

  8. An instrument to assess subjective task value beliefs regarding the decision to pursue postgraduate training.

    Science.gov (United States)

    Hagemeier, Nicholas E; Murawski, Matthew M

    2014-02-12

    To develop and validate an instrument to assess subjective ratings of the perceived value of various postgraduate training paths followed using expectancy-value as a theoretical framework; and to explore differences in value beliefs across type of postgraduate training pursued and type of pharmacy training completed prior to postgraduate training. A survey instrument was developed to sample 4 theoretical domains of subjective task value: intrinsic value, attainment value, utility value, and perceived cost. Retrospective self-report methodology was employed to examine respondents' (N=1,148) subjective task value beliefs specific to their highest level of postgraduate training completed. Exploratory and confirmatory factor analytic techniques were used to evaluate and validate value belief constructs. Intrinsic, attainment, utility, cost, and financial value constructs resulted from exploratory factor analysis. Cross-validation resulted in a 26-item instrument that demonstrated good model fit. Differences in value beliefs were noted across type of postgraduate training pursued and pharmacy training characteristics. The Postgraduate Training Value Instrument demonstrated evidence of reliability and construct validity. The survey instrument can be used to assess value beliefs regarding multiple postgraduate training options in pharmacy and potentially inform targeted recruiting of individuals to those paths best matching their own value beliefs.

  9. VARIABILITY OF OPTICAL COUNTERPARTS IN THE CHANDRA GALACTIC BULGE SURVEY

    Energy Technology Data Exchange (ETDEWEB)

    Britt, C. T.; Hynes, R. I.; Johnson, C. B.; Baldwin, A.; Collazzi, A.; Gossen, L. [Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA 70803-4001 (United States); Jonker, P. G.; Torres, M. A. P. [SRON, Netherlands Institute for Space Research, Sorbonnelaan 2, 3584 CA Utrecht (Netherlands); Nelemans, G. [Department of Astrophysics, IMAPP, Radboud University Nijmegen, Heyendaalseweg 135, 6525 AJ, Nijmegen (Netherlands); Maccarone, T. [Department of Physics, Texas Tech University, Box 41051, Science Building, Lubbock, TX 79409-1051 (United States); Steeghs, D.; Greiss, S. [Astronomy and Astrophysics, Department of Physics, University of Warwick, Coventry, CV4 7AL (United Kingdom); Heinke, C. [Department of Physics, University of Alberta, CCIS 4-183, Edmonton, AB T6G 2E1 (Canada); Bassa, C. G. [Jodrell Bank Centre for Astrophysics, School of Physics and Astronomy, University of Manchester, Manchester M13 9PL (United Kingdom); Villar, A. [Department of Physics, Massachussettes Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139-4307 (United States); Gabb, M. [Department of Physics, Florida Atlantic University, 777 Glades Road, Boca Raton, FL 33431-0991 (United States)

    2014-09-01

    We present optical light curves of variable stars consistent with the positions of X-ray sources identified with the Chandra X-ray Observatory for the Chandra Galactic Bulge Survey (GBS). Using data from the Mosaic-II instrument on the Blanco 4 m Telescope at CTIO, we gathered time-resolved photometric data on timescales from ∼2 hr to 8 days over the 3/4 of the X-ray survey containing sources from the initial GBS catalog. Among the light curve morphologies we identify are flickering in interacting binaries, eclipsing sources, dwarf nova outbursts, ellipsoidal variations, long period variables, spotted stars, and flare stars. Eighty-seven percent of X-ray sources have at least one potential optical counterpart. Twenty-seven percent of these candidate counterparts are detectably variable; a much greater fraction than expected for randomly selected field stars, which suggests that most of these variables are real counterparts. We discuss individual sources of interest, provide variability information on candidate counterparts, and discuss the characteristics of the variable population.

  10. Flood damage curves for consistent global risk assessments

    Science.gov (United States)

    de Moel, Hans; Huizinga, Jan; Szewczyk, Wojtek

    2016-04-01

    Assessing potential damage of flood events is an important component in flood risk management. Determining direct flood damage is commonly done using depth-damage curves, which denote the flood damage that would occur at specific water depths per asset or land-use class. Many countries around the world have developed flood damage models using such curves which are based on analysis of past flood events and/or on expert judgement. However, such damage curves are not available for all regions, which hampers damage assessments in those regions. Moreover, due to different methodologies employed for various damage models in different countries, damage assessments cannot be directly compared with each other, obstructing also supra-national flood damage assessments. To address these problems, a globally consistent dataset of depth-damage curves has been developed. This dataset contains damage curves depicting percent of damage as a function of water depth as well as maximum damage values for a variety of assets and land use classes (i.e. residential, commercial, agriculture). Based on an extensive literature survey concave damage curves have been developed for each continent, while differentiation in flood damage between countries is established by determining maximum damage values at the country scale. These maximum damage values are based on construction cost surveys from multinational construction companies, which provide a coherent set of detailed building cost data across dozens of countries. A consistent set of maximum flood damage values for all countries was computed using statistical regressions with socio-economic World Development Indicators from the World Bank. Further, based on insights from the literature survey, guidance is also given on how the damage curves and maximum damage values can be adjusted for specific local circumstances, such as urban vs. rural locations, use of specific building material, etc. This dataset can be used for consistent supra

  11. Assessing the local windfield with instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Zambrano, T.G.

    1980-10-01

    This report concerns the development and testing of a technique for the initial screening and evaluation of potential sites for wind-energy conversion systems (WECS). The methodology was developed through a realistic siting exercise. The siting exercise involved measurements of winds along the surface and winds aloft using a relatively new instrument system, the Tethered Aerodynamic Lifting Anemometer (TALA) kite; notation of ecological factors such as vegetation flagging, soil erosion and site exposure, and verification of an area best suited for wind-energy development by establishing and maintaining a wind monitoring network. The siting exercise was carried out in an approximately 100-square-mile region of the Tehachapi Mountains of Southern California. The results showed that a comprehensive site survey involving field measurements, ecological survey, and wind-monitoring can be an effective tool for preliminary evaluation of WECS sites.

  12. Instrumentation for Basic Research in Communication and Hearing Protection Systems

    National Research Council Canada - National Science Library

    Ray, Laura

    2004-01-01

    .... The instrumentation provided by this grant consists of an Artificial Head Measurement System, a Low Frequency Acoustic Test Cell, a vibration isolation table, and digital signal processing equipment...

  13. Using New Technologies for Time Diary Data Collection: Instrument Design and Data Quality Findings from a Mixed-Mode Pilot Survey.

    Science.gov (United States)

    Chatzitheochari, Stella; Fisher, Kimberly; Gilbert, Emily; Calderwood, Lisa; Huskinson, Tom; Cleary, Andrew; Gershuny, Jonathan

    2018-01-01

    Recent years have witnessed a steady growth of time-use research, driven by the increased research and policy interest in population activity patterns and their associations with long-term outcomes. There is recent interest in moving beyond traditional paper-administered time diaries to use new technologies for data collection in order to reduce respondent burden and administration costs, and to improve data quality. This paper presents two novel diary instruments that were employed by a large-scale multi-disciplinary cohort study in order to obtain information on the time allocation of adolescents in the United Kingdom. A web-administered diary and a smartphone app were created, and a mixed-mode data collection approach was followed: cohort members were asked to choose between these two modes, and those who were unable or refused to use the web/app modes were offered a paper diary. Using data from a pilot survey of 86 participants, we examine diary data quality indicators across the three modes. Results suggest that the web and app modes yield an overall better time diary data quality than the paper mode, with a higher proportion of diaries with complete activity and contextual information. Results also show that the web and app modes yield a comparable number of activity episodes to the paper mode. These results suggest that the use of new technologies can improve diary data quality. Future research using larger samples should systematically investigate selection and measurement effects in mixed-mode time-use survey designs.

  14. Measuring stakeholder participation in evaluation: an empirical validation of the Participatory Evaluation Measurement Instrument (PEMI).

    Science.gov (United States)

    Daigneault, Pierre-Marc; Jacob, Steve; Tremblay, Joël

    2012-08-01

    Stakeholder participation is an important trend in the field of program evaluation. Although a few measurement instruments have been proposed, they either have not been empirically validated or do not cover the full content of the concept. This study consists of a first empirical validation of a measurement instrument that fully covers the content of participation, namely the Participatory Evaluation Measurement Instrument (PEMI). It specifically examines (1) the intercoder reliability of scores derived by two research assistants on published evaluation cases; (2) the convergence between the scores of coders and those of key respondents (i.e., authors); and (3) the convergence between the authors' scores on the PEMI and the Evaluation Involvement Scale (EIS). A purposive sample of 40 cases drawn from the evaluation literature was used to assess reliability. One author per case in this sample was then invited to participate in a survey; 25 fully usable questionnaires were received. Stakeholder participation was measured on nominal and ordinal scales. Cohen's κ, the intraclass correlation coefficient, and Spearman's ρ were used to assess reliability and convergence. Reliability results ranged from fair to excellent. Convergence between coders' and authors' scores ranged from poor to good. Scores derived from the PEMI and the EIS were moderately associated. Evidence from this study is strong in the case of intercoder reliability and ranges from weak to strong in the case of convergent validation. Globally, this suggests that the PEMI can produce scores that are both reliable and valid.

  15. Consistent dynamical and statistical description of fission and comparison

    Energy Technology Data Exchange (ETDEWEB)

    Shunuan, Wang [Chinese Nuclear Data Center, Beijing, BJ (China)

    1996-06-01

    The research survey of consistent dynamical and statistical description of fission is briefly introduced. The channel theory of fission with diffusive dynamics based on Bohr channel theory of fission and Fokker-Planck equation and Kramers-modified Bohr-Wheeler expression according to Strutinsky method given by P.Frobrich et al. are compared and analyzed. (2 figs.).

  16. Factorial Validity and Internal Consistency of Malaysian Adapted Depression Anxiety Stress Scale - 21 in an Adolescent Sample

    OpenAIRE

    Hairul Anuar Hashim; Freddy Golok; Rosmatunisah Ali

    2011-01-01

    Background: Psychometrically sound measurement instrument is a fundamental requirement across broad range of research areas. In negative affect research, Depression Anxiety Stress Scale (DASS) has been identified as a psychometrically sound instrument to measure depression, anxiety and stress, especially the 21-item version. However, its psychometric properties in adolescents have been less consistent. Objectives: Thus, the present study sought to examine the factorial validity and internal c...

  17. Instruments and Taxonomy of Workplace Bullying in Health Care Organizations

    Directory of Open Access Journals (Sweden)

    Eun-Jun Park, PhD, RN

    2017-12-01

    Full Text Available Summary: Purpose: This study was aimed to evaluate the methodological issues and comprehensiveness of workplace bullying instruments and to suggest a taxonomy of psychological abuse. Methods: Nineteen instruments applied in health care organizations and 469 questionnaire items mainly regarding psychological abuse were collected through a literature review. Three researchers classified the questionnaire items according to a “taxonomy of psychological abuse in the workplace.” Results: Many instruments of workplace bullying were developed in the 2000s using a reflective measurement model, but their psychometric property was not sufficient and the measurement model is questioned. Based on the questionnaire items, the “taxonomy of psychological abuse in the workplace” was modified by adding two new subcategories (unachievable work and unfair treatment and clarifying some operational definitions. According to the modified taxonomy of 11 (subcategories, the reviewed instruments assessed 6.5 (subcategories on average. No instrument measured all (subcategories. Category 4.2 (disrespect, humiliation, and rejection of the person was measured in all instruments, followed by Categories 5 (professional discredit and denigration and 1.2 (social isolation behaviors. Conclusion: The current instruments are not comprehensive enough. It is suggested that the modified taxonomy is verified and guide more reliable and inclusive instruments in the future. Furthermore, a formative measurement model, which defines a bullying as an inventory of different types of behaviors, should be used. Keywords: aggression, bullying, hostility, mobbing, surveys and questionnaires

  18. Instrumentation

    International Nuclear Information System (INIS)

    Prieur, G.; Nadi, M.; Hedjiedj, A.; Weber, S.

    1995-01-01

    This second chapter on instrumentation gives little general consideration on history and classification of instrumentation, and two specific states of the art. The first one concerns NMR (block diagram of instrumentation chain with details on the magnets, gradients, probes, reception unit). The first one concerns precision instrumentation (optical fiber gyro-meter and scanning electron microscope), and its data processing tools (programmability, VXI standard and its history). The chapter ends with future trends on smart sensors and Field Emission Displays. (D.L.). Refs., figs

  19. Applying improved instrumentation and computer control systems

    International Nuclear Information System (INIS)

    Bevilacqua, F.; Myers, J.E.

    1977-01-01

    In-core and out-of-core instrumentation systems for the Cherokee-I reactor are described. The reactor has 61m-core instrument assemblies. Continuous computer monitoring and processing of data from over 300 fixed detectors will be used to improve the manoeuvering of core power. The plant protection system is a standard package for the Combustion Engineering System 80, consisting of two independent systems, the reactor protection system and the engineering safety features activation system, both of which are designed to meet NRC, ANS and IEEE design criteria or standards. The plants protection system has its own computer which provides plant monitoring, alarming, logging and performance calculations. (U.K.)

  20. Calibration through on-line monitoring of instruments channels

    International Nuclear Information System (INIS)

    James, R.W.

    1996-01-01

    Plant technical specifications require periodic calibration of instrument channels, and this has traditionally meant calibration at fixed time intervals for nearly all instruments. Experience has shown that unnecessarily frequent calibrations reduce channel availability and reliability, impact outage durations, and increase maintenance costs. An alternative approach to satisfying existing requirements for periodic calibration consists of on-line monitoring and quantitative comparison of instrument channels during operation to identify instrument degradation and failure. A Utility Working Group has been formed by EPRI to support the technical activities necessary to achieve generic NRC acceptance of on-line monitoring of redundant instrument channels as a basis for determining when to perform calibrations. A topical report proposing NRC acceptance of this approach was submitted in August 1995, and the Working Group is currently resolving NRC technical questions. This paper describes the proposed approach and the current status of the topical report with regard to NRC review. While these activities will not preclude utilities from continuing to use existing calibration approaches, successful acceptance of this performance-based approach will allow utilities to substantially reduce the number of calibrations which are performed. Concurrent benefits will include reduced I ampersand C impact on outage durations and improved sensitivity to instrument channel performance

  1. Calibration procedure for Slocum glider deployed optical instruments.

    Science.gov (United States)

    Cetinić, Ivona; Toro-Farmer, Gerardo; Ragan, Matthew; Oberg, Carl; Jones, Burton H

    2009-08-31

    Recent developments in the field of the autonomous underwater vehicles allow the wide usage of these platforms as part of scientific experiments, monitoring campaigns and more. The vehicles are often equipped with sensors measuring temperature, conductivity, chlorophyll a fluorescence (Chl a), colored dissolved organic matter (CDOM) fluorescence, phycoerithrin (PE) fluorescence and spectral volume scattering function at 117 degrees, providing users with high resolution, real time data. However, calibration of these instruments can be problematic. Most in situ calibrations are performed by deploying complementary instrument packages or water samplers in the proximity of the glider. Laboratory calibrations of the mounted sensors are difficult due to the placement of the instruments within the body of the vehicle. For the laboratory calibrations of the Slocum glider instruments we developed a small calibration chamber where we can perform precise calibrations of the optical instruments aboard our glider, as well as sensors from other deployment platforms. These procedures enable us to obtain pre- and post-deployment calibrations for optical fluorescence instruments, which may differ due to the biofouling and other physical damage that can occur during long-term glider deployments. We found that biofouling caused significant changes in the calibration scaling factors of fluorescent sensors, suggesting the need for consistent and repetitive calibrations for gliders as proposed in this paper.

  2. An Exploratory Survey of Teachers' Attitudes toward Sex-Stereotyping.

    Science.gov (United States)

    Minix, Nancy A.; And Others

    This survey examined the attitudes of teachers in southwestern Kentucky toward sex-stereotyping in the classroom. A random sample of 35 teachers of grades kindergarten through adult completed a written survey instrument that asked them to read statements regarding sex-stereotyping and to rate themselves regarding their own classroom practices.…

  3. Adaptation and testing of psychosocial assessment instruments for cross-cultural use: an example from the Thailand Burma border.

    Science.gov (United States)

    Haroz, Emily E; Bass, Judith K; Lee, Catherine; Murray, Laura K; Robinson, Courtland; Bolton, Paul

    2014-01-01

    The purpose of this study was to develop valid and reliable instruments to assess priority psychosocial problems and functioning among adult survivors of systematic violence from Burma living in Thailand. The process involved four steps: 1) instrument drafting and piloting; 2) reliability and validity testing; 3) instrument revision; and 4) retesting revised instrument. A total of N = 158 interviews were completed. Overall subscales showed good internal consistency (0.73-0.92) and satisfactory combined test-retest/inter rater reliability (0.63-0.84). Criterion validity, was not demonstrated for any scale. The alcohol and functioning scales underperformed and were revised (step 3) and retested (step 4). Upon retesting, the function scale showed good internal consistency reliability (0.91-0.92), and the alcohol scale showed acceptable internal consistency (0.79) and strong test-retest/inter-rater reliability (0.86-0.89). This paper describes the importance and process of adaptation and testing, illustrated by the experiences and results for selected instruments in this population.

  4. New analytical portable instrument for microchip electrophoresis with electrochemical detection.

    Science.gov (United States)

    Fernández-la-Villa, Ana; Pozo-Ayuso, Diego F; Castaño-Alvarez, Mario

    2010-08-01

    A new portable instrument that includes a high voltage power supply, a bipotentiostat, and a chip holder has been especially developed for using microchips electrophoresis with electrochemical detection. The main unit of the instrument has dimensions of 150 x 165 x 70 mm (wxdxh) and consists of a four-outputs high voltage power supply with a maximum voltage of +/-3 KV and an acquisition system with two channels for dual amperometric (DC or pulsed amperometric detection) detection. Electrochemical detection has been selected as signal transduction method because it is relatively easily implemented, since nonoptical elements are required. The system uses a lithium-ion polymer battery and it is controlled from a desktop or laptop PC with a graphical user interface based on LabVIEW connected by serial RS232 or Bluetooth. The last part of the system consists of a reusable chip holder for housing the microchips, which contain all the electrical connections and reservoirs for making the work with microchips easy. The performance of the new instrument has been evaluated and compared with other commercially available apparatus using single- and dual-channel pyrex microchips for the separation of the neurotransmitters dopamine, epinephrine, and 3,4-dihydroxy-L-phenyl-alanine. The reduction of the size of the instrument has not affected the good performance of the separation and detection using microchips electrophoresis with electrochemical detection. Moreover, the new portable instrument paves the way for in situ analysis making the use of microchips electrophoresis easier.

  5. Methodology for performing surveys for fixed contamination

    International Nuclear Information System (INIS)

    Durham, J.S.; Gardner, D.L.

    1994-10-01

    This report describes a methodology for performing instrument surveys for fixed contamination that can be used to support the release of material from radiological areas, including release to controlled areas and release from radiological control. The methodology, which is based on a fast scan survey and a series of statistical, fixed measurements, meets the requirements of the U.S. Department of Energy Radiological Control Manual (RadCon Manual) (DOE 1994) and DOE Order 5400.5 (DOE 1990) for surveys for fixed contamination and requires less time than a conventional scan survey. The confidence interval associated with the new methodology conforms to the draft national standard for surveys. The methodology that is presented applies only to surveys for fixed contamination. Surveys for removable contamination are not discussed, and the new methodology does not affect surveys for removable contamination

  6. Assessing an organizational culture instrument based on the Competing Values Framework: Exploratory and confirmatory factor analyses

    Science.gov (United States)

    Helfrich, Christian D; Li, Yu-Fang; Mohr, David C; Meterko, Mark; Sales, Anne E

    2007-01-01

    Background The Competing Values Framework (CVF) has been widely used in health services research to assess organizational culture as a predictor of quality improvement implementation, employee and patient satisfaction, and team functioning, among other outcomes. CVF instruments generally are presented as well-validated with reliable aggregated subscales. However, only one study in the health sector has been conducted for the express purpose of validation, and that study population was limited to hospital managers from a single geographic locale. Methods We used exploratory and confirmatory factor analyses to examine the underlying structure of data from a CVF instrument. We analyzed cross-sectional data from a work environment survey conducted in the Veterans Health Administration (VHA). The study population comprised all staff in non-supervisory positions. The survey included 14 items adapted from a popular CVF instrument, which measures organizational culture according to four subscales: hierarchical, entrepreneurial, team, and rational. Results Data from 71,776 non-supervisory employees (approximate response rate 51%) from 168 VHA facilities were used in this analysis. Internal consistency of the subscales was moderate to strong (α = 0.68 to 0.85). However, the entrepreneurial, team, and rational subscales had higher correlations across subscales than within, indicating poor divergent properties. Exploratory factor analysis revealed two factors, comprising the ten items from the entrepreneurial, team, and rational subscales loading on the first factor, and two items from the hierarchical subscale loading on the second factor, along with one item from the rational subscale that cross-loaded on both factors. Results from confirmatory factor analysis suggested that the two-subscale solution provides a more parsimonious fit to the data as compared to the original four-subscale model. Conclusion This study suggests that there may be problems applying conventional

  7. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  8. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2001-01-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor

  9. A borehole instrumentation program for characterization of unsaturated-zone percolation

    International Nuclear Information System (INIS)

    Kume, J.; Rousseau, J.P.

    1994-01-01

    A borehole instrumentation and monitoring program has been designed by the US Geological Survey to support site characterization of unsaturated-zone percolation at Yucca Mountain, Nye County, Nevada. This program provides a means of defining the unsaturated-zone fluid flow (liquid and gas) potential field in a setting that incorporates large-scale stratigraphic and structural features, and the influences of geothermal heat flow and atmospheric pressure changes. Data derived from this program will be used to evaluate the suitability of Yucca Mountain as a mined geologic-repository for the storage of high-level, radioactive waste. These data include in-situ temperature, pneumatic pressure, and water potential. In addition, the instrumentation program provides facilities for gas-sampling, gas-tracer diffusion testing, water-injection testing, water-level monitoring, neutron moisture-meter monitoring, temperature profiling, and in-situ recalibration of the downhole sensors. The program included testing and development of: (1) precision sensors for measurement; (2) a downhole instrumentation-station-apparatus to house the sensors, recalibrate sensors in-situ, and allow access to instrument stations for other testing purposes; and (3) surface-based support and instrumentation facilities

  10. Development and initial validation of the Pharmacist Frequency of Interprofessional Collaboration Instrument (FICI-P) in primary care.

    Science.gov (United States)

    Van, Connie; Costa, Daniel; Mitchell, Bernadette; Abbott, Penny; Krass, Ines

    2012-01-01

    Existing validated measures of pharmacist-physician collaboration focus on measuring attitudes toward collaboration and do not measure frequency of collaborative interactions. To develop and validate an instrument to measure the frequency of collaboration between pharmacists and general practitioners (GPs) from the pharmacist's perspective. An 11-item Pharmacist Frequency of Interprofessional Collaboration Instrument (FICI-P) was developed and administered to 586 pharmacists in 8 divisions of general practice in New South Wales, Australia. The initial items were informed by a review of the literature in addition to interviews of pharmacists and GPs. Items were subjected to principal component and Rasch analyses to determine each item's and the overall measure's psychometric properties and for any needed refinements. Two hundred and twenty four (38%) of pharmacist surveys were completed and returned. Principal component analysis suggested removal of 1 item for a final 1-factor solution. The refined 10-item FICI-P demonstrated internal consistency reliability at Cronbach's alpha=0.90. After collapsing the original 5-point response scale to a 4-point response scale, the refined FICI-P demonstrated fit to the Rasch model. Criterion validity of the FICI-P was supported by the correlation of FICI-P scores with scores on a previously validated Physician-Pharmacist Collaboration Instrument. Validity was also supported by predicted differences in FICI-P scores between subgroups of respondents stratified on age, colocation with GPs, and interactions during the intern-training period. The refined 10-item FICI-P was shown to have good internal consistency, criterion validity, and fit to the Rasch model. The creation of such a tool may allow for the measure of impact in the evaluation of interventions designed to improve interprofessional collaboration between GPs and pharmacists. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Instruments Measuring Integrated Care: A Systematic Review of Measurement Properties.

    Science.gov (United States)

    Bautista, Mary Ann C; Nurjono, Milawaty; Lim, Yee Wei; Dessers, Ezra; Vrijhoef, Hubertus Jm

    2016-12-01

    -centered care (49%); fewer studies measured care continuity/comprehensive care (15%) and care coordination/case management (3%). We mapped 84% of the measured constructs to the clinical integration domain of the RMIC, with fewer constructs related to the domains of professional (3.7%), organizational (3.4%), and functional (0.5%) integration. Only 8% of the instruments were mapped to a combination of domains; none were mapped exclusively to the system or normative integration domains. The majority of instruments were administered to either patients (60%) or health care providers (20%). Of the measurement properties, responsiveness (4%), measurement error (7%), and criterion (12%) and cross-cultural validity (14%) were less commonly reported. We found measurement properties. Only a minority of index instruments showed strong evidence of positive findings for internal consistency (15%), content validity (19%), and structural validity (7%); with moderate evidence of positive findings for internal consistency (14%) and construct validity (14%). Our results suggest that the quality of measurement properties of instruments measuring integrated care is in need of improvement with the less-studied constructs and domains to become part of newly developed instruments. © 2016 Milbank Memorial Fund.

  12. Instruments Measuring Integrated Care: A Systematic Review of Measurement Properties

    Science.gov (United States)

    BAUTISTA, MARY ANN C.; NURJONO, MILAWATY; DESSERS, EZRA; VRIJHOEF, HUBERTUS JM

    2016-01-01

    integration (33%) and patient‐centered care (49%); fewer studies measured care continuity/comprehensive care (15%) and care coordination/case management (3%). We mapped 84% of the measured constructs to the clinical integration domain of the RMIC, with fewer constructs related to the domains of professional (3.7%), organizational (3.4%), and functional (0.5%) integration. Only 8% of the instruments were mapped to a combination of domains; none were mapped exclusively to the system or normative integration domains. The majority of instruments were administered to either patients (60%) or health care providers (20%). Of the measurement properties, responsiveness (4%), measurement error (7%), and criterion (12%) and cross‐cultural validity (14%) were less commonly reported. We found measurement properties. Only a minority of index instruments showed strong evidence of positive findings for internal consistency (15%), content validity (19%), and structural validity (7%); with moderate evidence of positive findings for internal consistency (14%) and construct validity (14%). Conclusions Our results suggest that the quality of measurement properties of instruments measuring integrated care is in need of improvement with the less‐studied constructs and domains to become part of newly developed instruments. PMID:27995711

  13. Instrument accuracy in reactor vessel inventory tracking systems

    International Nuclear Information System (INIS)

    Anderson, J.L.; Anderson, R.L.; Morelock, T.C.; Hauang, T.L.; Phillips, L.E.

    1986-01-01

    Instrumentation needs for detection of inadequate core cooling. Studies of the Three Mile Island accident identified the need for additional instrumentation to detect inadequate core cooling (ICC) in nuclear power plants. Industry studies by plant owners and reactor vendors supported the conclusion that improvements were needed to help operators diagnose the approach to or existence of ICC as well as to provide more complete information for operator control of safety injection flow to minimize the consequences of such an accident. In 1980, the US Nuclear Regulatory Commission (NRC) required further studies by the industry and described ICC instrumentation design requirements that included human factors and environmental considerations. On December 10, 1982, NRC issued to Babcock and Wilcox (B and W) licensees orders for Modification of License and transmitted to pressurized water reactor licensees Generic Letter 82-28 to inform them of the revised NRC requirements. The instrumentation requirements include upgraded subcooling margin monitors (SMM), upgraded core exit thermocouples (CET), and installation of a reactor coolant inventory tracking system. NRC Regulatory Guide 1.97, which covers accident monitoring instrumentation, was revised (Rev. 3) to be consistent with the requirements of item II.F.2 of NUREG-0737

  14. An OECD comparison of wind power and photovoltaics - approach to a consistent survey

    International Nuclear Information System (INIS)

    Wagner, H.J.; Ziemons, S.

    1996-01-01

    Adequate solutions are expected from renewable energy sources that may stop ozone depletion and contribute to resource conservation. Almost any OECD country is making efforts to promote photovoltaics and wind power. To give a survey of the measures taken and results obtained promotion programs are compared and the success achieved in the individual OECD countries is outlined. National energy institutions were interviewed and their 1993/94 programs were evaluated. Some of the data and statements are incomplete. (orig.) [de

  15. A new algorithm to build bridges between two patient-reported health outcome instruments: the MOS SF-36® and the VR-12 Health Survey.

    Science.gov (United States)

    Selim, Alfredo; Rogers, William; Qian, Shirley; Rothendler, James A; Kent, Erin E; Kazis, Lewis E

    2018-04-19

    To develop bridging algorithms to score the Veterans Rand-12 (VR-12) scales for comparability to those of the SF-36® for facilitating multi-cohort studies using data from the National Cancer Institute Surveillance, Epidemiology, and End Results Program (SEER) linked to Medicare Health Outcomes Survey (MHOS), and to provide a model for minimizing non-statistical error in pooled analyses stemming from changes to survey instruments over time. Observational study of MHOS cohorts 1-12 (1998-2011). We modeled 2-year follow-up SF-36 scale scores from cohorts 1-6 based on baseline SF-36 scores, age, and gender, yielding 100 clusters using Classification and Regression Trees. Within each cluster, we averaged follow-up SF-36 scores. Using the same cluster specifications, expected follow-up SF-36 scores, based on cohorts 1-6, were computed for cohorts 7-8 (where the VR-12 was the follow-up survey). We created a new criterion validity measure, termed "extensibility," calculated from the square root of the mean square difference between expected SF-36 scale averages and observed VR-12 item score from cohorts 7-8, weighted by cluster size. VR-12 items were rescored to minimize this quantity. Extensibility of rescored VR-12 items and scales was considerably improved from the "simple" scoring method for comparability to the SF-36 scales. The algorithms are appropriate across a wide range of potential subsamples within the MHOS and provide robust application for future studies that span the SF-36 and VR-12 eras. It is possible that these surveys in a different setting outside the MHOS, especially in younger age groups, could produce somewhat different results.

  16. PreCam: A Precursor Observational Campaign for Calibration of the Dark Energy Survey

    Energy Technology Data Exchange (ETDEWEB)

    Kuehn, K.; Kuhlmann, S.; Allam, S.; Annis, J. T.; Bailey, T.; Balbinot, E.; Bernstein, J. P.; Biesiadzinski, T.; Burke, D. L.; Butner, M.; Camargo, J. I. B.; da Costa, L. A. N.; DePoy, D.; Diehl, H. T.; Dietrich, J. P.; Estrada, J.; Fausti, A.; Gerke, B.; Guarino, V.; Head, H. H.; Kessler, R.; Lin, H.; Lorenzon, W.; Maia, M. A. G.; Maki, L.; Marshall, J.; Nord, B.; Neilsen, E.; Ogando, R. L. C.; Park, D.; Peoples, J.; Rastawicki, D.; Rheault, J. -P.; Santiago, B.; Schubnell, M.; Seitzer, P.; Smith, J. A.; Spinka, H.; Sypniewski, A.; Tarle, G.; Tucker, D. L.; Walker, A. R.; Wester, W.

    2013-04-01

    PreCam, a precursor observational campaign supporting the Dark Energy Survey (DES), is designed to produce a photometric and astrometric catalog of nearly a hundred thousand standard stars within the DES footprint, while the PreCam instrument also serves as a prototype testbed for the Dark Energy Camera's hardware and software. This catalog represents a potential 100-fold increase in Southern Hemisphere photometric standard stars, and therefore will be an important component in the calibration of the Dark Energy Survey. We provide details on the PreCam instrument's design, construction, and testing, as well as results from a subset of the 51 nights of PreCam survey observations on the University of Michigan Department of Astronomy's Curtis-Schmidt telescope at Cerro Tololo Inter-American Observatory (CTIO). We briefly describe the preliminary data processing pipeline that has been developed for PreCam data and the preliminary results of the instrument performance, as well as astrometry and photometry of a sample of stars previously included in other southern sky surveys.

  17. A multi-criteria evaluation method for climate change mitigation policy instruments

    International Nuclear Information System (INIS)

    Konidari, Popi; Mavrakis, Dimitrios

    2007-01-01

    This paper presents an integrated multi-criteria analysis method for the quantitative evaluation of climate change mitigation policy instruments. The method consists of: (i) a set of criteria supported by sub-criteria, all of which describe the complex framework under which these instruments are selected by policy makers and implemented, (ii) an Analytical Hierarchy Process (AHP) process for defining weight coefficients for criteria and sub-criteria according to the preferences of three stakeholders groups and (iii) a Multi-Attribute Theory (MAUT)/Simple Multi-Attribute Ranking Technique (SMART) process for assigning grades to each instrument that is evaluated for its performance under a specific sub-criterion. Arguments for the selected combination of these standard methods and definitions for criteria/sub-criteria are quoted. Consistency and robustness tests are performed. The functionality of the proposed method is tested by assessing the aggregate performances of the EU emission trading scheme at Denmark, Germany, Greece, Italy, Netherlands, Portugal, Sweden and United Kingdom. Conclusions are discussed

  18. Reliability, precision, and measurement in the context of data from ability tests, surveys, and assessments

    International Nuclear Information System (INIS)

    Fisher, W P Jr; Elbaum, B; Coulter, A

    2010-01-01

    Reliability coefficients indicate the proportion of total variance attributable to differences among measures separated along a quantitative continuum by a testing, survey, or assessment instrument. Reliability is usually considered to be influenced by both the internal consistency of a data set and the number of items, though textbooks and research papers rarely evaluate the extent to which these factors independently affect the data in question. Probabilistic formulations of the requirements for unidimensional measurement separate consistency from error by modelling individual response processes instead of group-level variation. The utility of this separation is illustrated via analyses of small sets of simulated data, and of subsets of data from a 78-item survey of over 2,500 parents of children with disabilities. Measurement reliability ultimately concerns the structural invariance specified in models requiring sufficient statistics, parameter separation, unidimensionality, and other qualities that historically have made quantification simple, practical, and convenient for end users. The paper concludes with suggestions for a research program aimed at focusing measurement research more on the calibration and wide dissemination of tools applicable to individuals, and less on the statistical study of inter-variable relations in large data sets.

  19. Independent Orbiter Assessment (IOA): Assessment of instrumental subsystem FMEA/CIL

    Science.gov (United States)

    Gardner, J. R.; Addis, A. W.

    1988-01-01

    The McDonnell Douglas Astronautics Company (MDAC) was selected in June 1986 to perform an Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL). The IOA effort first completed an analysis of the Instrumentation hardware, generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the NASA FMEA/CIL baseline. A resolution of each discrepancy from the comparison is provided through additional analysis as required. The results of that comparison for the Orbiter Instrumentation hardware are documented. The IOA product for Instrumentation analysis consisted of 107 failure mode worksheets that resulted in 22 critical items being identified. Comparison was made to the Pre 51-L NASA baseline with 14 Post 51-L FMEAs added, which consists of 96 FMEAs and 18 CIL items. This comparison produced agreement on all but 25 FMEAs which caused differences in 5 CIL items.

  20. Testing concordance of instrumental variable effects in generalized linear models with application to Mendelian randomization

    Science.gov (United States)

    Dai, James Y.; Chan, Kwun Chuen Gary; Hsu, Li

    2014-01-01

    Instrumental variable regression is one way to overcome unmeasured confounding and estimate causal effect in observational studies. Built on structural mean models, there has been considerale work recently developed for consistent estimation of causal relative risk and causal odds ratio. Such models can sometimes suffer from identification issues for weak instruments. This hampered the applicability of Mendelian randomization analysis in genetic epidemiology. When there are multiple genetic variants available as instrumental variables, and causal effect is defined in a generalized linear model in the presence of unmeasured confounders, we propose to test concordance between instrumental variable effects on the intermediate exposure and instrumental variable effects on the disease outcome, as a means to test the causal effect. We show that a class of generalized least squares estimators provide valid and consistent tests of causality. For causal effect of a continuous exposure on a dichotomous outcome in logistic models, the proposed estimators are shown to be asymptotically conservative. When the disease outcome is rare, such estimators are consistent due to the log-linear approximation of the logistic function. Optimality of such estimators relative to the well-known two-stage least squares estimator and the double-logistic structural mean model is further discussed. PMID:24863158

  1. Results of an EMI/RFI plant survey

    International Nuclear Information System (INIS)

    Shankar, R.; Mollerus, F.J.

    1993-01-01

    This paper summarizes the results of a telephone survey to collect information concerning electromagnetic interference/radio frequency interference (EMI/RFI) problems primarily at nuclear power plants. The survey found that problem sources such as two-way radios and welding have been largely resolved by procedural control and use of sound-power phone systems. Additional investigation and testing appear appropriate for noise interference related to grounding of electrical equipment and instrumentation

  2. Survey, applications, and prospects of Johnson noise thermometry

    International Nuclear Information System (INIS)

    Blalock, T.V.; Shepard, R.L.

    1981-01-01

    Significant progress in the field of Johnson noise thermometry has occurred since the 1971 survey of Kamper. This paper will review the foundation work of Johnson noise thermometry, survey the basic methods which do not utilize quantum devices for noise thermometry for industrial temperatures, and present some applications of noise thermometry in temperature scale metrology and process temperature instrumentation. 35 references

  3. The Development of the STEM Career Interest Survey (STEM-CIS)

    Science.gov (United States)

    Kier, Meredith W.; Blanchard, Margaret R.; Osborne, Jason W.; Albert, Jennifer L.

    2014-06-01

    Internationally, efforts to increase student interest in science, technology, engineering, and mathematics (STEM) careers have been on the rise. It is often the goal of such efforts that increased interest in STEM careers should stimulate economic growth and enhance innovation. Scientific and educational organizations recommend that efforts to interest students in STEM majors and careers begin at the middle school level, a time when students are developing their own interests and recognizing their academic strengths. These factors have led scholars to call for instruments that effectively measure interest in STEM classes and careers, particularly for middle school students. In response, we leveraged the social cognitive career theory to develop a survey with subscales in science, technology, engineering, and mathematics. In this manuscript, we detail the six stages of development of the STEM Career Interest Survey. To investigate the instrument's reliability and psychometric properties, we administered this 44-item survey to over 1,000 middle school students (grades 6-8) who primarily were in rural, high-poverty districts in the southeastern USA. Confirmatory factor analyses indicate that the STEM-CIS is a strong, single factor instrument and also has four strong, discipline-specific subscales, which allow for the science, technology, engineering, and mathematics subscales to be administered separately or in combination. This instrument should prove helpful in research, evaluation, and professional development to measure STEM career interest in secondary level students.

  4. A review of instruments to measure interprofessional team-based primary care.

    Science.gov (United States)

    Shoemaker, Sarah J; Parchman, Michael L; Fuda, Kathleen Kerwin; Schaefer, Judith; Levin, Jessica; Hunt, Meaghan; Ricciardi, Richard

    2016-07-01

    Interprofessional team-based care is increasingly regarded as an important feature of delivery systems redesigned to provide more efficient and higher quality care, including primary care. Measurement of the functioning of such teams might enable improvement of team effectiveness and could facilitate research on team-based primary care. Our aims were to develop a conceptual framework of high-functioning primary care teams to identify and review instruments that measure the constructs identified in the framework, and to create a searchable, web-based atlas of such instruments (available at: http://primarycaremeasures.ahrq.gov/team-based-care/ ). Our conceptual framework was developed from existing frameworks, the teamwork literature, and expert input. The framework is based on an Input-Mediator-Output model and includes 12 constructs to which we mapped both instruments as a whole, and individual instrument items. Instruments were also reviewed for relevance to measuring team-based care, and characterized. Instruments were identified from peer-reviewed and grey literature, measure databases, and expert input. From nearly 200 instruments initially identified, we found 48 to be relevant to measuring team-based primary care. The majority of instruments were surveys (n = 44), and the remainder (n = 4) were observational checklists. Most instruments had been developed/tested in healthcare settings (n = 30) and addressed multiple constructs, most commonly communication (n = 42), heedful interrelating (n = 42), respectful interactions (n = 40), and shared explicit goals (n = 37). The majority of instruments had some reliability testing (n = 39) and over half included validity testing (n = 29). Currently available instruments offer promise to researchers and practitioners to assess teams' performance, but additional work is needed to adapt these instruments for primary care settings.

  5. [Psychometric properties of an instrument for assessing cyber-sex addiction].

    Science.gov (United States)

    Ballester Arnal, Rafael; Gil Llario, Ma Dolores; Gómez Martínez, Sandra; Gil Juliá, Beatriz

    2010-11-01

    Psychometric properties of an instrument for assessing cyber-sex addiction. Cyber-sex addiction is a «new pathology» whose prevalence has grown rapidly in recent years. Therefore, it is important to have validated assessment instruments. The aim of this study was the adaptation and validation of the Internet Sex Screening Test (ISST) for its use in a Spanish population. The instrument was administered to 1239 Spanish college students. The results yielded five components that account for 47.5% of the variance. Internal consistency was .88 and temporal stability was .84. Moreover, the instrument had adequate convergent and discriminant validity and was related to other behaviors such as the use of pornography, internet addiction, number of hours online and sexual frequency. Therefore, this tool is proposed as an appropriate measure to assess cyber-sex addiction.

  6. Measuring decision quality: psychometric evaluation of a new instrument for breast cancer chemotherapy.

    Science.gov (United States)

    Lee, Clara N; Wetschler, Matthew H; Chang, Yuchiao; Belkora, Jeffrey K; Moy, Beverly; Partridge, Ann; Sepucha, Karen R

    2014-08-20

    Women diagnosed with early stage (I or II) breast cancer face a highly challenging decision - whether or not to undergo adjuvant chemotherapy. We developed a decision quality instrument for chemotherapy for early stage breast cancer and sought to evaluate its performance. Cross-sectional, mailed survey of recent breast cancer survivors, providers, and healthy controls and a retest survey of survivors. The decision quality instrument includes questions on knowledge and personal goals. It results in a knowledge score and concordance score, which reflects the percentage of patients who received treatments that match their goals. Hypotheses related to acceptability, feasibility, validity, and reliability of the survey instrument were examined. Responses were received from 352 patients, 89 providers and 35 healthy controls. The decision quality instrument was feasible to implement with few missing data. The knowledge scores had good retest reliability (intraclass correlation coefficient (ICC) =0.75). Knowledge scores discriminated between providers and patients (mean difference 31.1%, 95% CI 26.9, 35.3) and between patients and healthy controls (mean difference 11.2, 95% CI 5.4, 17.1). Most providers reported that the knowledge items covered essential content. Two of the five goal items had a ceiling effect, and one goal had low content validity. The goal items had moderate retest reliability (ICC's 0.57 to 0.78). In the multivariable model of treatment, none of the patient goals was associated with receipt of chemotherapy. Age and hormone receptor status were the only variables independently associated with chemotherapy. Most patients (77.6%) had treatment concordant with that predicted by the model. Patients who had concordant treatment had similar levels of confidence and regret as those who did not. The Decision Quality Instrument is a reliable and valid measure of patient knowledge about chemotherapy, but its ability to measure concordance with patient goals is

  7. Fine-scale environmental effects on Cape hake survey catch rates in the Northern Benguela, using data from a trawl-mounted instrument package

    DEFF Research Database (Denmark)

    Kainge, Paulus Inekela; Wieland, Kai

    2017-01-01

    We investigated fine-scale effects of environmental variables associated with habitat distribution for 4 size groups of Cape hakes, Merluccius capensis and M. paradoxus, using generalized additive models (GAMs) with a negative binominal error distribution. This study took place during the Namibian...... hake trawl survey of 2016, and was made possible for the first time in Namibia by collecting oceanographic information with a trawl-mounted instrument package concurrently with the catch data. Depth, geographical position, bottom oxygen and bottom temperature had the most pronounced effect on the catch...... rates of both hake species, whereas solar zenith angle representing diel effects and surface layer chlorophyll appeared to be less important. The explained deviance for the best models ranged from 71.4% for M. capensis to 92.7% for M. paradoxus between 43 and 57 cm in length. Differences in catch rates...

  8. Comparison of Satellite Surveying to Traditional Surveying Methods for the Resources Industry

    Science.gov (United States)

    Osborne, B. P.; Osborne, V. J.; Kruger, M. L.

    Modern ground-based survey methods involve detailed survey, which provides three-space co-ordinates for surveyed points, to a high level of accuracy. The instruments are operated by surveyors, who process the raw results to create survey location maps for the subject of the survey. Such surveys are conducted for a location or region and referenced to the earth global co- ordinate system with global positioning system (GPS) positioning. Due to this referencing the survey is only as accurate as the GPS reference system. Satellite survey remote sensing utilise satellite imagery which have been processed using commercial geographic information system software. Three-space co-ordinate maps are generated, with an accuracy determined by the datum position accuracy and optical resolution of the satellite platform.This paper presents a case study, which compares topographic surveying undertaken by traditional survey methods with satellite surveying, for the same location. The purpose of this study is to assess the viability of satellite remote sensing for surveying in the resources industry. The case study involves a topographic survey of a dune field for a prospective mining project area in Pakistan. This site has been surveyed using modern surveying techniques and the results are compared to a satellite survey performed on the same area.Analysis of the results from traditional survey and from the satellite survey involved a comparison of the derived spatial co- ordinates from each method. In addition, comparisons have been made of costs and turnaround time for both methods.The results of this application of remote sensing is of particular interest for survey in areas with remote and extreme environments, weather extremes, political unrest, poor travel links, which are commonly associated with mining projects. Such areas frequently suffer language barriers, poor onsite technical support and resources.

  9. Validity of instruments to assess students' travel and pedestrian safety.

    Science.gov (United States)

    Mendoza, Jason A; Watson, Kathy; Baranowski, Tom; Nicklas, Theresa A; Uscanga, Doris K; Hanfling, Marcus J

    2010-05-18

    Safe Routes to School (SRTS) programs are designed to make walking and bicycling to school safe and accessible for children. Despite their growing popularity, few validated measures exist for assessing important outcomes such as type of student transport or pedestrian safety behaviors. This research validated the SRTS school travel survey and a pedestrian safety behavior checklist. Fourth grade students completed a brief written survey on how they got to school that day with set responses. Test-retest reliability was obtained 3-4 hours apart. Convergent validity of the SRTS travel survey was assessed by comparison to parents' report. For the measure of pedestrian safety behavior, 10 research assistants observed 29 students at a school intersection for completion of 8 selected pedestrian safety behaviors. Reliability was determined in two ways: correlations between the research assistants' ratings to that of the Principal Investigator (PI) and intraclass correlations (ICC) across research assistant ratings. The SRTS travel survey had high test-retest reliability (kappa = 0.97, n = 96, p < 0.001) and convergent validity (kappa = 0.87, n = 81, p < 0.001). The pedestrian safety behavior checklist had moderate reliability across research assistants' ratings (ICC = 0.48) and moderate correlation with the PI (r = 0.55, p = < 0.01). When two raters simultaneously used the instrument, the ICC increased to 0.65. Overall percent agreement (91%), sensitivity (85%) and specificity (83%) were acceptable. These validated instruments can be used to assess SRTS programs. The pedestrian safety behavior checklist may benefit from further formative work.

  10. Validation of an instrument for mathematics enhancement teaching efficacy of Pacific Northwest agricultural educators

    Science.gov (United States)

    Jansen, Daniel J.

    Teacher efficacy continues to be an important area of study in educational research. This study tested an instrument designed to assess the perceived efficacy of agricultural education teachers when engaged in lessons involving mathematics instruction. The study population of Oregon and Washington agricultural educators utilized in the validation of the instrument revealed important demographic findings and specific results related to teacher efficacy for the study population. An instrument was developed from the assimilation of three scales previously used and validated in efficacy research. Participants' mathematics teaching efficacy was assessed using a portion of the Mathematics Teaching Efficacy Beliefs Instrument (MTEBI), and personal mathematics efficacy was evaluated by the mathematics self-belief instrument which was derived from the Betz and Hackett's Mathematics Self-Efficacy Scale. The final scale, the Teachers' Sense of Efficacy Scale (TSES) created by Tschannen-Moran and Woolfolk Hoy, examined perceived personal teaching efficacy. Structural equation modeling was used as the statistical analyses tool to validate the instrument and examine correlations between efficacy constructs used to determine potential professional development needs of the survey population. As part of the data required for validation of the Mathematics Enhancement Teaching Efficacy instrument, demographic information defining the population of Oregon and Washington agricultural educators was obtained and reported. A hypothetical model derived from teacher efficacy literature was found to be an acceptable model to verify construct validity and determine strength of correlations between the scales that defined the instrument. The instrument produced an alpha coefficient of .905 for reliability. Both exploratory and confirmatory factor analyses were used to verify construct and discriminate validity. Specifics results related to the survey population of agricultural educators

  11. Evaluation of construct and criterion validity for the 'Liverpool Osteoarthritis in Dogs' (LOAD clinical metrology instrument and comparison to two other instruments.

    Directory of Open Access Journals (Sweden)

    Myles Benjamin Walton

    Full Text Available To test the 'Liverpool Osteoarthritis in Dogs' (LOAD questionnaire for construct and criterion validity, and to similarly test the Helsinki Chronic Pain Index (HCPI and the Canine Brief Pain Inventory (CBPI.Prospective Study.222 dogs with osteoarthritis.Osteoarthritis was diagnosed in a cohort of dogs on the basis of clinical history and orthopedic examination. Force-platform analysis was performed and a "symmetry index" for peak vertical force (PVF was calculated. Owners completed LOAD, CBPI and HCPI instruments. As a test of construct validity, inter-instrument correlations were calculated. As a test of criterion validity, the correlations between instrument scores and PVF symmetry scores were calculated. Additionally, internal consistency of all instruments was calculated and compared to those previously reported. Factor analysis is reported for the first time for LOAD, and is compared to that previously reported for CBPI and HCPI.Significant moderate correlations were found between all instruments, implying construct validity for all instruments. Significant weak correlations were found between LOAD scores and PVF symmetry index, and between CBPI scores and PVF symmetry index.LOAD is an owner-completed clinical metrology instrument that can be recommended for the measurement of canine osteoarthritis. It is convenient to use, validated and, as demonstrated here for the first time, has a correlation with force-platform data.

  12. Safety Evaluation of Kartini Reactor Based on Instrumentation System Design

    International Nuclear Information System (INIS)

    Tjipta Suhaemi; Djen Djen Dj; Itjeu K; Johnny S; Setyono

    2003-01-01

    The safety of Kartini reactor has been evaluated based on instrumentation system aspect. The Kartini reactor is designed by BATAN. Design power of the reactor is 250 kW, but it is currently operated at 100 kW. Instrumentation and control system function is to monitor and control the reactor operation. Instrumentation and control system consists of safety system, start-up and automatic power control, and process information system. The linear power channel and logarithmic power channel are used for measuring power. There are 3 types of control rod for controlling the power, i.e. safety rod, shim rod, and regulating rod. The trip and interlock system are used for safety. There are instrumentation equipment used for measuring radiation exposure, flow rate, temperature and conductivity of fluid The system of Kartini reactor has been developed by introducing a process information system, start-up system, and automatic power control. It is concluded that the instrumentation of Kartini reactor has followed the requirement and standard of IAEA. (author)

  13. Victoreen panoramic 470 A survey meter

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-07-01

    This instrument is a portable, battery powered, survey meter covering an exposure rate range from 0 to 1000 R h -1 . and an exposure range of 0 to 1000 mR. It is designed to measure X- and γ-radiation over a wide range of energies and angular distributions, and also to detect alpha and beta radiation. The radiation detector is an unsealed ionisation chamber. The report describes the instrument under the following headings: facilities and controls; radiation characteristics; electrical characteristics; environmental characteristics; mechanical characteristics; the manual; summary of performance. (U.K.)

  14. Development of an instrument designed to measure employees' perceptions of workplace breastfeeding support.

    Science.gov (United States)

    Greene, Sally W; Olson, Beth H

    2008-09-01

    Breastfeeding rates remain low in the United States, especially among working women. Unfortunately, no quantitative instrument exists to facilitate the examination of why women who return to work discontinue breastfeeding sooner than the general population. The objective of this study was to develop an instrument to measure female employees' perceptions of breastfeeding support in the workplace, which would be suitable for piloting with the target population. Examination of the literature, reviews with experts, and one-on-one interviews with women who had experience combining breastfeeding and work were used to create the instrument subscales and items. Examination of the literature was used to develop four subscales: company policies/work culture, manager support, co-worker support, and workflow. Expert review resulted in the addition of a fifth subscale, the physical environment of the breastfeeding space. One-on-one interviews were used to ensure that the item wording was appropriate for the target population. Eighteen items were added, and 15 were reworded based on comments from the expert review and from the interviews. The resulting survey contained 54 items that required either categorical yes/no or Likert scale responses. Results from this process indicate the survey subscales and items adequately reflect women's perceptions of breastfeeding support in the workplace and the instrument is appropriate for piloting with new mother employees.

  15. Validity and reliability of the Mastication Observation and Evaluation (MOE) instrument.

    Science.gov (United States)

    Remijn, Lianne; Speyer, Renée; Groen, Brenda E; van Limbeek, Jacques; Nijhuis-van der Sanden, Maria W G

    2014-07-01

    The Mastication Observation and Evaluation (MOE) instrument was developed to allow objective assessment of a child's mastication process. It contains 14 items and was developed over three Delphi rounds. The present study concerns the further development of the MOE using the COSMIN (Consensus based Standard for the Selection of Measurement Instruments) and investigated the instrument's internal consistency, inter-observer reliability, construct validity and floor and ceiling effects. Consumption of three bites of bread and biscuit was evaluated using the MOE. Data of 59 healthy children (6-48 mths) and 38 children (bread) and 37 children (biscuit) with cerebral palsy (24-72 mths) were used. Four items were excluded before analysis due to zero variance. Principal Components Analysis showed one factor with 8 items. Internal consistency was >0.70 (Chronbach's alpha) for both food consistencies and for both groups of children. Inter-observer reliability varied from 0.51 to 0.98 (weighted Gwet's agreement coefficient). The total MOE scores for both groups showed normal distribution for the population. There were no floor or ceiling effects. The revised MOE now contains 8 items that (a) have a consistent concept for mastication and can be scored on a 4-point scale with sufficient reliability and (b) are sensitive to stages of chewing development in young children. The removed items are retained as part of a criterion referenced list within the MOE. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Psychometric Evaluation of the Hospital Culture of Transitions Survey.

    Science.gov (United States)

    McClelland, Mark; Bena, James; Albert, Nancy M; Pines, Jesse M

    2017-10-01

    Ineffective or inefficient transitions threaten patient safety, hinder communication, and worsen patient outcomes. The Hospital Culture of Transitions (H-CulT) survey was designed to assess a hospital's organizational culture related to within-hospital transitions in care involving patient movement. In this article, psychometric properties of the H-CulT survey were examined to assess and refine the hospital culture of transitions. A cross-sectional, multicenter, multidisciplinary correlational design and survey methods were used to examine the psychometric properties of the H-CulT survey. Exploratory factor analysis was used to quantify the accuracy of the previously identified structure. Specifically, the analysis involved the principal axis factor method with an oblique rotation, based on a polychoric correlation matrix. A sample of 492 respondents from 13 diverse hospitals participated. Cronbach's alpha for the instrument was 0.88, indicating strong internal consistency. Seven subscales emerged and were labeled: Hospital Leadership, Unit Leadership, My Unit's Culture, Other Units' Culture, Busy Workload, Priority of Patient Care, and Use of Data. Correlations between subscales ranged from 0.07 to 0.52, providing evidence that the subscales did not measure the same construct. Subscale correlations with the total score were near or above 0.50 (p <0.001). Use of a factor-loading cutoff of 0.40 resulted in the elimination of 12 items because of weak associations with the topic. The H-CulT is a psychometrically sound and practical survey for assessing hospital culture related to patient flow during transitions in care. Survey results may prompt quality improvement interventions that enhance in-hospital transitions and improve staff satisfaction and patient satisfaction with care. Copyright © 2017 The Joint Commission. Published by Elsevier Inc. All rights reserved.

  17. Proceedings of the spring meeting of the Study Group for Electronic Instrumentation on April 3-5, 1995 in Juelich

    International Nuclear Information System (INIS)

    1995-06-01

    The 17 papers presented at the meeting give a survey of recent progress in the field of electronic instrumentation of scientific and technical measuring instruments, achieved at the research centers of KFA Juelich, TU Graz, HMI Berlin, Karlsruhe FZ, and Rossendorf FZ. (DG) [de

  18. An instrument to characterize the environment for residents' evidence-based medicine learning and practice.

    Science.gov (United States)

    Mi, Misa; Moseley, James L; Green, Michael L

    2012-02-01

    Many residency programs offer training in evidence-based medicine (EBM). However, these curricula often fail to achieve optimal learning outcomes, perhaps because they neglect various contextual factors in the learning environment. We developed and validated an instrument to characterize the environment for EBM learning and practice in residency programs. An EBM Environment Scale was developed following scale development principles. A survey was administered to residents across six programs in primary care specialties at four medical centers. Internal consistency reliability was analyzed with Cronbach's coefficient alpha. Validity was assessed by comparing predetermined subscales with the survey's internal structure as assessed via factor analysis. Scores were also compared for subgroups based on residency program affiliation and residency characteristics. Out of 262 eligible residents, 124 completed the survey (response rate 47%). The overall mean score was 3.89 (standard deviation=0.56). The initial reliability analysis of the 48-item scale had a high reliability coefficient (Cronbach α=.94). Factor analysis and further item analysis resulted in a shorter 36-item scale with a satisfactory reliability coefficient (Cronbach α=.86). Scores were higher for residents with prior EBM training in medical school (4.14 versus 3.62) and in residency (4.25 versus 3.69). If further testing confirms its properties, the EBM Environment Scale may be used to understand the influence of the learning environment on the effectiveness of EBM training. Additionally, it may detect changes in the EBM learning environment in response to programmatic or institutional interventions.

  19. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  20. ECLSS Integration Analysis: Advanced ECLSS Subsystem and Instrumentation Technology Study for the Space Exploration Initiative

    Science.gov (United States)

    1990-01-01

    In his July 1989 space policy speech, President Bush proposed a long range continuing commitment to space exploration and development. Included in his goals were the establishment of permanent lunar and Mars habitats and the development of extended duration space transportation. In both cases, a major issue is the availability of qualified sensor technologies for use in real-time monitoring and control of integrated physical/chemical/biological (p/c/b) Environmental Control and Life Support Systems (ECLSS). The purpose of this study is to determine the most promising instrumentation technologies for future ECLSS applications. The study approach is as follows: 1. Precursor ECLSS Subsystem Technology Trade Study - A database of existing and advanced Atmosphere Revitalization (AR) and Water Recovery and Management (WRM) ECLSS subsystem technologies was created. A trade study was performed to recommend AR and WRM subsystem technologies for future lunar and Mars mission scenarios. The purpose of this trade study was to begin defining future ECLSS instrumentation requirements as a precursor to determining the instrumentation technologies that will be applicable to future ECLS systems. 2. Instrumentation Survey - An instrumentation database of Chemical, Microbial, Conductivity, Humidity, Flowrate, Pressure, and Temperature sensors was created. Each page of the sensor database report contains information for one type of sensor, including a description of the operating principles, specifications, and the reference(s) from which the information was obtained. This section includes a cursory look at the history of instrumentation on U.S. spacecraft. 3. Results and Recommendations - Instrumentation technologies were recommended for further research and optimization based on a consideration of both of the above sections. A sensor or monitor technology was recommended based on its applicability to future ECLS systems, as defined by the ECLSS Trade Study (1), and on whether its

  1. Measuring Diversity and Inclusion in Academic Medicine: The Diversity Engagement Survey (DES)

    Science.gov (United States)

    Person, Sharina D.; Jordan, C. Greer; Allison, Jeroan J.; Fink Ogawa, Lisa M.; Castillo-Page, Laura; Conrad, Sarah; Nivet, Marc A.; Plummer, Deborah L.

    2018-01-01

    Purpose To produce a physician and scientific workforce capable of delivering high quality, culturally competent health care and research, academic medical centers must assess their capacity for diversity and inclusion and respond to identified opportunities. Thus, the Diversity Engagement Survey (DES) is presented as a diagnostic and benchmarking tool. Method The 22-item DES connects workforce engagement theory with inclusion and diversity constructs. Face and content validity were established based on decades of previous work to promote institutional diversity. The survey was pilot tested at a single academic medical center and subsequently administered at 13 additional academic medical centers. Cronbach alphas assessed internal consistency and Confirmatory Factor Analysis (CFA) established construct validity. Criterion validity was assessed by observed separation in scores for groups traditionally recognized to have less workforce engagement. Results The sample consisted of 13,694 individuals at 14 medical schools from across the U.S. who responded to the survey administered between 2011– 2012. The Cronbach alphas for inclusion and engagement factors (range: 0.68 to 0.85), CFA fit indices, and item correlations with latent constructs, indicated an acceptable model fit and that questions measured the intended concepts. DES scores clearly distinguished higher and lower performing institutions. The DES detected important disparities for black, women, and those who did not have heterosexual orientation. Conclusions This study demonstrated that the DES is a reliable and valid instrument for internal assessment and evaluation or external benchmarking of institutional progress in building inclusion and engagement. PMID:26466376

  2. Intelligent type sodium instrumentations for LMFR

    International Nuclear Information System (INIS)

    Daolong Chen

    1996-01-01

    The constructions and their performances of a lot of newly developed intelligent type sodium instrumentations that consist of the intelligent type sodium flowmeter, the intelligent type immersed sodium flowmeter, the intelligent type sodium manometer and the intelligent type sodium level gauge are described. The graduation characteristic equations for corresponding transducer using the medium temperature as the parameter are given. Because the operating temperature limit of measured medium (sodium) is wide, so the on-line compensation of the temperature effect of their graduation characteristics much be considered. The tests show that these intelligent type sodium instrumentations possess of good linearity. The accurate sodium process parameter (flowrate, pressure and level) measurement data can be obtained by means of their on-line compensation function of the temperature effect. Moreover, these intelligent type sodium instrumentations possess of the self-inspection, the electric shutoff protection, the setting of full-scale, the setting of alarm limits (two upper limits and two lower limits alarms), the thermocouple breaking alarm, each other isolative the 0-10V direct-current analogue output and CENTRONICS standard digital output, and the alarm relay contact output. These intelligent type sodium instrumentations are suitable particularly for the instrument, control and protective systems of LMFR by means of these excellent functions based on microprocessor. The basic error of the intelligent type sodium flowmeter, immersed sodium flowmeter, sodium manometer and sodium level gauge is respectively ±2%, ±2.3%, ±0.3% and ±1.9% of measuring range. (author). 4 refs, 9 figs

  3. Designing and conducting survey research a comprehensive guide

    CERN Document Server

    Rea, Louis M

    2014-01-01

    The industry standard guide, updated with new ideas and SPSS analysis techniques Designing and Conducting Survey Research: A Comprehensive Guide Fourth Edition is the industry standard resource that covers all major components of the survey process, updated to include new data analysis techniques and SPSS procedures with sample data sets online. The book offers practical, actionable guidance on constructing the instrument, administrating the process, and analyzing and reporting the results, providing extensive examples and worksheets that demonstrate the appropriate use of survey and data tech

  4. The market for process control instrumentation in France. Foreign market survey report

    International Nuclear Information System (INIS)

    1977-04-01

    The market research was undertaken to study the present and potential US share of the market in France for process control instrumentation; to examine growth trends in French end-user industries over the next few years; to identify specific product categories that offer the most promising export potential for US companies; and to provide basic data which will assist US suppliers in determining current and potential sales and marketing opportunities. The trade promotional and marketing techniques were also reviewed

  5. The use of economic instruments for environmental policy: a half-hearted affair

    DEFF Research Database (Denmark)

    Andersen, Mikael Skou

    1995-01-01

    their use of economic instruments, but with a few exceptions it has been a somewhat half-hearted affair. Economic imstruments have often been applied on the basis of the principle of the least political resistance. Using Wilson's regulation theory (1980), this paper analyses how the costs and benefits......As a key to a more sustainable development the use of economic instruments for environmental policy has been on the agenda for about eight years. Despite of that, a recent OECD survey recorded only a modest increase in their use since the mid-1980s. In particular the Nordic counries have increased...... of regulations and particular policy-instruments affect the use and design of economic instruments. The outcome has been green taxes that are often fiscally biased , which are too low compared with the externalities they should price and which address the smaller rather than the larger polluters, granting...

  6. An Ethnobotanical Survey on Fuel Wood and Timber plant Species ...

    African Journals Online (AJOL)

    A survey was conducted to explore the fuel wood species and timber producing species of Kaghan valleys, Pakistan. Consumption pattern and impact on the forest resources were also taken into consideration. A questionnaire was used as a survey instrument to obtain desired data. For this study, 10 villages were randomly ...

  7. Instrument pre-development activities for FLEX

    Science.gov (United States)

    Pettinato, L.; Fossati, E.; Coppo, P. M.; Taiti, A.; Labate, D.; Capanni, A.; Taccola, M.; Bézy, J. L.; Francois, M.; Meynart, R.; Erdmann, L.; Triebel, P.

    2017-09-01

    The FLuorescence Imaging Spectrometer (FLORIS) is the payload of the FLuorescence Explorer Mission (FLEX) of the European Space Agency. The mission objective is to perform quantitative measurements of the solar induced vegetation fluorescence to monitor photosynthetic activity. FLORIS works in a push-broom configuration and it is designed to acquire data in the 500-780 nm spectral range, with a sampling of 0.1 nm in the oxygen bands (759-769 nm and 686- 697 nm) and 0.5-2.0 nm in the red edge, chlorophyll absorption and Photochemical Reflectance Index bands. FLEX will fly in formation with Sentinel-3 to benefit of the measurements made by the Sentinel-3 instruments OLCI and SLSTR, particularly for cloud screening, proper characterization of the atmospheric state and determination of the surface temperature. The instrument concept is based on a common telescope and two modified Offner spectrometers with reflective concave gratings both for the High Resolution (HR) and Low Resolution (LR) spectrometers. In the frame of the instrument pre-development Leonardo Company (I) has built and tested an elegant breadboard of the instrument consisting of the telescope and the HR spectrometer. The development of the LR spectrometer is in charge of OHB System AG (D) and is currently in the manufacturing phase. The main objectives of the activity are: anticipate the development of the instrument and provide early risk retirement of critical components, evaluate the system performances such as imaging quality parameters, straylight, ghost, polarization sensitivity and environmental influences, verify the adequacy of critical tests such as spectral characterization and straylight, define and optimize instrument alignment procedures. Following a brief overview of the FLEX mission, the paper will cover the design and the development of the optics breadboard with emphasis on the results obtained during the tests and the lessons learned for the flight unit.

  8. Emotional support, instrumental support, and gambling participation among Filipino Americans.

    Science.gov (United States)

    Kim, Isok; Kim, Wooksoo; Nochajski, Thomas H

    2014-08-01

    Using representative survey data of Filipino Americans in Honolulu and San Francisco (SF) (N = 2,259), we examined the roles of emotional support and instrumental support on gambling participation. With considerable difference in gambling environments between two regions, we conducted two sets of hierarchical regression analyses for Honolulu sample, which has restricted gambling laws, and SF sample, which has legal gambling environment, and compared the effects of two types of social support on gambling participation. The results indicated that emotional support was positively and instrumental support was negatively associated with gambling participation among Filipino Americans in Honolulu. However, neither type of social support was significantly associated with gambling participation among Filipino Americans living in SF. This study highlights the differing roles and effects of instrumental and emotional support on gambling where gambling is restricted. It also suggests that gambling behaviors of Filipino Americans are subject to situation- and environment-specific factors.

  9. Instrument Remote Control via the Astronomical Instrument Markup Language

    Science.gov (United States)

    Sall, Ken; Ames, Troy; Warsaw, Craig; Koons, Lisa; Shafer, Richard

    1998-01-01

    The Instrument Remote Control (IRC) project ongoing at NASA's Goddard Space Flight Center's (GSFC) Information Systems Center (ISC) supports NASA's mission by defining an adaptive intranet-based framework that provides robust interactive and distributed control and monitoring of remote instruments. An astronomical IRC architecture that combines the platform-independent processing capabilities of Java with the power of Extensible Markup Language (XML) to express hierarchical data in an equally platform-independent, as well as human readable manner, has been developed. This architecture is implemented using a variety of XML support tools and Application Programming Interfaces (API) written in Java. IRC will enable trusted astronomers from around the world to easily access infrared instruments (e.g., telescopes, cameras, and spectrometers) located in remote, inhospitable environments, such as the South Pole, a high Chilean mountaintop, or an airborne observatory aboard a Boeing 747. Using IRC's frameworks, an astronomer or other scientist can easily define the type of onboard instrument, control the instrument remotely, and return monitoring data all through the intranet. The Astronomical Instrument Markup Language (AIML) is the first implementation of the more general Instrument Markup Language (IML). The key aspects of our approach to instrument description and control applies to many domains, from medical instruments to machine assembly lines. The concepts behind AIML apply equally well to the description and control of instruments in general. IRC enables us to apply our techniques to several instruments, preferably from different observatories.

  10. A survey of environmental exposure amongst locoshed workers by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Singh, V.K.N.; Garg, A.N.

    1995-01-01

    Instrumental neutron activation analysis (INAA) has been used for the determination of 16 elements in hair of locoshed workers (n=10) to study environmental exposure. A comparison of mean elemental contents with control (n=11) shows a significant enhancement for Cr, Th, Ca, Se and Na whereas Br and Sb show a declining trend. (author). 4 refs., 1 tab

  11. Lessons learnt on recruitment and fieldwork from a pilot European human biomonitoring survey

    DEFF Research Database (Denmark)

    Fiddicke, Ulrike; Becker, Kerstin; Schwedler, Gerda

    2015-01-01

    , training of interviewers in all issues of recruitment, fieldwork and sampling through information material and training sessions is crucial. A survey involving many European countries needs time for preparation and conduct. Materials for quality control prepared for all steps of recruitment, fieldwork...... biomonitoring (HBM) survey which came into action as the pilot study DEMOCOPHES (DEMOnstration of a study to COordinate and Perform Human biomonitoring on a European Scale). Seventeen European countries conducted a survey with harmonized instruments for, inter alia, recruitment, fieldwork and sampling......, in autumn/winter 2011/2012. Based on the countries' experiences of conducting the pilot study, following lessons learnt were compiled: the harmonized fieldwork instruments (basic questionnaire, urine and hair sampling) turned out to be very valuable for future HBM surveys on the European scale. A school...

  12. Safety Assessment of Two Hybrid Instrumentation Techniques in a Dental Student Endodontic Clinic: A Retrospective Study.

    Science.gov (United States)

    Coelho, Marcelo Santos; Card, Steven John; Tawil, Peter Zahi

    2017-03-01

    The aim of this study was to retrospectively assess the safety potential of a hybrid technique combining nickel-titanium (NiTi) reciprocating and rotary instruments by third- and fourth-year dental students in the predoctoral endodontics clinic at one U.S. dental school. For the study, 3,194 root canal treatments performed by 317 dental students from 2012 through 2015 were evaluated for incidence of ledge creation and instrument separation. The hybrid reciprocating and rotary technique (RRT) consisted of a glide path creation with stainless steel hand files up to size 15/02, a crown down preparation with a NiTi reciprocating instrument, and an apical preparation with NiTi rotary instruments. The control was a traditional rotary and hand technique (RHT) that consisted of the same glide path procedure followed by a crown down preparation with NiTi rotary instruments and an apical preparation with NiTi hand instruments. The results showed that the RHT technique presented a rate of ledge creation of 1.4% per root and the RRT technique was 0.5% per root (protary technique for root canal instrumentation by these dental students provided good safety. This hybrid technique offered a low rate of ledge creation along with no NiTi instrument separation.

  13. Implementing a cornerstone of culture change: Consistent staff assignment in VHA community living centers.

    Science.gov (United States)

    Lemke, Sonne; Brennan, Penny L; SooHoo, Sonya; Schutte, Kathleen K

    2017-08-01

    In 2011, the Veterans Health Administration (VHA) began implementing consistent staff assignment in its nursing homes (called Community Living Centers or CLCs). Consistent assignment, a cornerstone of culture change, minimizes the number of staff who provide a resident's care. The present research assessed the level and stability of consistent assignment in units within VHA CLCs and identified unit characteristics related to implementation of this staff assignment model. Schedulers in 185 of 335 organizational units that make up VHA CLCs completed a Staffing Practices Survey. For the month prior to the survey, 53% of CLC units had full implementation of consistent assignment. Tracked back over time, 37% of CLC units had stable high consistent assignment, 29% had stable low consistent assignment, and 34% were variable. Units with stable high consistent assignment were most likely to use care teams with stable membership and to obtain staff input for care assignments. Schedulers in these units reported more positive experiences with consistent staff assignment and better unit functioning in terms of staff absences, complaints about workload fairness, and resolution of scheduling problems. Units with stable low and variable consistent assignment were similar in most of these respects; however, units with variable consistent assignment made greater use of stable care teams and were less likely to change assignments at a staff member's request. Overall, consistent assignment implementation was not related to unit size, nursing hours per resident day, or specialty focus. Findings can help guide consistent staff assignment implementation in VHA and community nursing homes. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  14. Instrument to determine prestress remaining in a damaged bridge girder

    Science.gov (United States)

    Civjan, Scott A.; Jirsa, James O.; Carrasquillo, Ramon L.; Fowler, David W.

    1998-03-01

    An instrument has been developed to estimate stress levels in prestress strands in existing members. The prototype instrument applies a lateral load to an exposed prestressing strand and measures the resulting displacements. The instrument was calibrated for 0.5-inch (12.7 mm) diameter seven-wire strand with exposed lengths of 1.5 feet (0.46 m) to 3.75 feet (1.14 m). It was tested to determine its accuracy, precision, and usefulness in the field. Strand forces were consistently estimated to within ten percent of the actual load. The device was also utilized in the placement of strand splices and was found to be more reliable in checking induced strand tensions than the standard torque wrench method.

  15. Development and application of a novel crop stress and quality instrument

    Science.gov (United States)

    Huang, Wengjiang; Sun, Gang; Wang, Jihua; Liu, Liangyun; Zheng, Wengang

    2005-12-01

    In this paper, a portable diagnostic instrument for crop quality analysis was designed and tested, which can measure the normalized difference vegetation index (PRI) and structure insensitive pigment index (NRI) of crop canopy in the field. The instrument have a valid survey area of 1m×1m when the height between instrument and the ground was fixed to 1.3 meter. The crop quality can be assessed based on their PRI and NRI values, so it will be very important for crop management to get these values. The instrument uses sunlight as its light source. There are six special different photoelectrical detectors within red, blue and near infrared bands, which are used for detecting incidence sunlight and reflex light from the canopy of crop. This optical instrument includes photoelectric detector module, signal process and A/D convert module, the data storing and transmission module and human-machine interface module. The detector is the core of the instrument which measures the spectrums at special bands. The microprocessor calculates the NDVI and SIPI value based on the A/D value. And the value can be displayed on the instrument's LCD, stored in the flash memory of instrument and can also be uploaded to PC through the PC's RS232 serial interface. The prototype was tested in the crop field at different view directions. It reveals the on-site and non-sampling mode of crop growth monitoring by fixed on the agricultural machine traveling in the field. Such simple instruments can diagnose the plant growth status by the acquired spectral response.

  16. Instrumentation project of 3rd desalination plant at Tuas (Singapore)

    OpenAIRE

    Charco Iniesta, Sara

    2016-01-01

    This project consists on the description of instrumentation used in Tuas III desalination plant at Singapore and its flow process description. The project has been developed as part of the work of the instrumentation department of the responsible company of the engineering design of Tuas III desalination plant. First of all is important to know the water problems which suffer all the people who live in Singapore. Singapore is a city-state and is home to 5.5 million residents. The coun...

  17. Reliability of Instruments Measuring At-Risk and Problem Gambling Among Young Individuals

    DEFF Research Database (Denmark)

    Edgren, Robert; Castrén, Sari; Mäkelä, Marjukka

    2016-01-01

    This review aims to clarify which instruments measuring at-risk and problem gambling (ARPG) among youth are reliable and valid in light of reported estimates of internal consistency, classification accuracy, and psychometric properties. A systematic search was conducted in PubMed, Medline, and Psyc......Info covering the years 2009–2015. In total, 50 original research articles fulfilled the inclusion criteria: target age under 29 years, using an instrument designed for youth, and reporting a reliability estimate. Articles were evaluated with the revised Quality Assessment of Diagnostic Accuracy Studies tool....... Reliability estimates were reported for five ARPG instruments. Most studies (66%) evaluated the South Oaks Gambling Screen Revised for Adolescents. The Gambling Addictive Behavior Scale for Adolescents was the only novel instrument. In general, the evaluation of instrument reliability was superficial. Despite...

  18. Using XML and Java Technologies for Astronomical Instrument Control

    Science.gov (United States)

    Ames, Troy; Case, Lynne; Powers, Edward I. (Technical Monitor)

    2001-01-01

    Traditionally, instrument command and control systems have been highly specialized, consisting mostly of custom code that is difficult to develop, maintain, and extend. Such solutions are initially very costly and are inflexible to subsequent engineering change requests, increasing software maintenance costs. Instrument description is too tightly coupled with details of implementation. NASA Goddard Space Flight Center, under the Instrument Remote Control (IRC) project, is developing a general and highly extensible framework that applies to any kind of instrument that can be controlled by a computer. The software architecture combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML), a human readable and machine understandable way to describe structured data. A key aspect of the object-oriented architecture is that the software is driven by an instrument description, written using the Instrument Markup Language (IML), a dialect of XML. IML is used to describe the command sets and command formats of the instrument, communication mechanisms, format of the data coming from the instrument, and characteristics of the graphical user interface to control and monitor the instrument. The IRC framework allows the users to define a data analysis pipeline which converts data coming out of the instrument. The data can be used in visualizations in order for the user to assess the data in real-time, if necessary. The data analysis pipeline algorithms can be supplied by the user in a variety of forms or programming languages. Although the current integration effort is targeted for the High-resolution Airborne Wideband Camera (HAWC) and the Submillimeter and Far Infrared Experiment (SAFIRE), first-light instruments of the Stratospheric Observatory for Infrared Astronomy (SOFIA), the framework is designed to be generic and extensible so that it can be applied to any instrument. Plans are underway to test the framework

  19. Factor Structure, Internal Consistency, and Screening Sensitivity of the GARS-2 in a Developmental Disabilities Sample

    Directory of Open Access Journals (Sweden)

    Martin A. Volker

    2016-01-01

    Full Text Available The Gilliam Autism Rating Scale-Second Edition (GARS-2 is a widely used screening instrument that assists in the identification and diagnosis of autism. The purpose of this study was to examine the factor structure, internal consistency, and screening sensitivity of the GARS-2 using ratings from special education teaching staff for a sample of 240 individuals with autism or other significant developmental disabilities. Exploratory factor analysis yielded a correlated three-factor solution similar to that found in 2005 by Lecavalier for the original GARS. Though the three factors appeared to be reasonably consistent with the intended constructs of the three GARS-2 subscales, the analysis indicated that more than a third of the GARS-2 items were assigned to the wrong subscale. Internal consistency estimates met or exceeded standards for screening and were generally higher than those in previous studies. Screening sensitivity was .65 and specificity was .81 for the Autism Index using a cut score of 85. Based on these findings, recommendations are made for instrument revision.

  20. Age Weights for Health Services Derived from the Relative Social Willingness-to-Pay Instrument.

    Science.gov (United States)

    Richardson, Jeff; McKie, John; Iezzi, Angelo; Maxwell, Aimee

    2017-04-01

    The effect of a patient's age on the social valuation of health services remains controversial, with empirical results varying in magnitude and implying a different age-value profile. This article employs a new methodology to re-examine these questions. Data were obtained from 2 independent Web-based surveys that administered the Relative Social Willingness to Pay instrument. In the first survey, the age of the patient receiving a life-saving service was varied. Patients were left with either poor mental or physical health. In the second survey, patient age was varied for a service that fully cured the patient's poor mental or physical health. In total, therefore, 4 sets of age weights were obtained: weights for life-extending services with poor physical or mental health outcomes and weights for quality-of-life improvement for patients in poor mental or physical health. Results were consistent. Increasing age was associated in each case with a monotonic decrease in the social valuation of the services. The decrease in value was quantitatively small until age 60 years. By age 80 years, the social value of services had declined by about 50%. The decline commenced at an earlier age in the context of physical health, although the magnitude of the decrement by age 80 years was unrelated to the type of service. With 1 exception, there was little difference in the valuation of services by the age of the survey respondent. Respondents aged >60 years placed a lower, not higher, value on quality-of-life improvement for elderly individuals than other respondents. There was no difference in the valuation of life-extending services.

  1. Mobile Music, Sensors, Physical Modeling, and Digital Fabrication: Articulating the Augmented Mobile Instrument

    Directory of Open Access Journals (Sweden)

    Romain Michon

    2017-12-01

    Full Text Available Two concepts are presented, extended, and unified in this paper: mobile device augmentation towards musical instruments design and the concept of hybrid instruments. The first consists of using mobile devices at the heart of novel musical instruments. Smartphones and tablets are augmented with passive and active elements that can take part in the production of sound (e.g., resonators, exciter, etc., add new affordances to the device, or change its global aesthetics and shape. Hybrid instruments combine physical/acoustical and “physically informed” virtual/digital elements. Recent progress in physical modeling of musical instruments and digital fabrication is exploited to treat instrument parts in a multidimensional way, allowing any physical element to be substituted with a virtual one and vice versa (as long as it is physically possible. A wide range of tools to design mobile hybrid instruments is introduced and evaluated. Aesthetic and design considerations when making such instruments are also presented through a series of examples.

  2. The HIFI spectral survey of AFGL 2591 (CHESS). II. Summary of the survey

    Science.gov (United States)

    Kaźmierczak-Barthel, M.; van der Tak, F. F. S.; Helmich, F. P.; Chavarría, L.; Wang, K.-S.; Ceccarelli, C.

    2014-07-01

    Aims: This paper presents the richness of submillimeter spectral features in the high-mass star forming region AFGL 2591. Methods: As part of the Chemical Herschel Survey of Star Forming Regions (CHESS) key programme, AFGL 2591 was observed by the Herschel (HIFI) instrument. The spectral survey covered a frequency range from 480 to 1240 GHz as well as single lines from 1267 to 1901 GHz (i.e. CO, HCl, NH3, OH, and [CII]). Rotational and population diagram methods were used to calculate column densities, excitation temperatures, and the emission extents of the observed molecules associated with AFGL 2591. The analysis was supplemented with several lines from ground-based JCMT spectra. Results: From the HIFI spectral survey analysis a total of 32 species were identified (including isotopologues). Although the lines are mostly quite weak (∫TmbdV ~ few K km s-1), 268 emission and 16 absorption lines were found (excluding blends). Molecular column densities range from 6 × 1011 to 1 × 1019 cm-2 and excitation temperatures from 19 to 175 K. Cold (e.g. HCN, H2S, and NH3 with temperatures below 70 K) and warm species (e.g. CH3OH, SO2) in the protostellar envelope can be distinguished. Herschel is an ESA space observatory with science instruments provided by European-led Principal Investigator consortia and with important participation from NASA.Appendix A is available in electronic form at http://www.aanda.org

  3. Confirmatory factor analysis of teaching and learning guiding principles instrument among teacher educators in higher education institutions

    Science.gov (United States)

    Masuwai, Azwani; Tajudin, Nor'ain Mohd; Saad, Noor Shah

    2017-05-01

    The purpose of this study is to develop and establish the validity and reliability of an instrument to generate teaching and learning guiding principles using Teaching and Learning Guiding Principles Instrument (TLGPI). Participants consisted of 171 Malaysian teacher educators. It is an essential instrument to reflect in generating the teaching and learning guiding principles in higher education level in Malaysia. Confirmatory Factor Analysis has validated all 19 items of TLGPI whereby all items indicated high reliability and internal consistency. A Confirmatory Factor Analysis also confirmed that a single factor model was used to generate teaching and learning guiding principles.

  4. Core outcome measurement instruments for clinical trials in non-specific low back pain

    DEFF Research Database (Denmark)

    Chiarotto, Alessandro; Boers, Maarten; Deyo, Richard A

    2017-01-01

    Disability Index version 2.1a (ODI 2.1a) for physical functioning (78% agreement) and the Numeric Rating Scale (NRS) for pain intensity (75% agreement). No consensus was achieved on any HRQoL instrument, although the Short Form 12 (SF12) approached the consensus threshold (64% agreement). In Round 2...... COSMIN methodology. Researchers, clinicians and patients (n = 207) were invited in a two-round Delphi survey to generate consensus ( ≥ 67% agreement among participants) on which instruments to endorse. Response rates were 44% and 41%, respectively. In Round 1, consensus was achieved on the Oswestry......, consensus was reached on a NRS version with a 1-week recall period (96% agreement). Various participants requested one free-to-use instrument per domain. Considering all issues together, recommendations on core instruments were formulated: ODI 2.1a or 24-item Roland-Morris Disability Questionnaire...

  5. Status of the JWST Integrated Science Instrument Module

    Science.gov (United States)

    Greenhouse, Matthew A.; Dunn, Jamie; Kimble, Randy A.; Lambros, Scott; Lundquist, Ray; Rauscher, Bernard J.; Van Campen, Julie

    2015-01-01

    The James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM) is the science instrument payload of the JWST. It is one of three system elements that comprise the JWST space vehicle. It consists of four science sensors, a fine guidance sensor, and nine other subsystems that support them. At 1.4 metric tons, it comprises approximately 20% of the JWST mass. The ISIM is currently at 100% integration and has completed 2 of 3 planned element-level space simulation tests. The ISIM is on schedule to be delivered for integration with the Optical Telescope Element during 2015. In this poster, we present an overview of the ISIM and its status.

  6. Determination of uranium and thorium in rock samples from Harargaj Anticline by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Rahman, M.; Molla, N.I.; Sharif, A.K.M.; Basunia, S.; Islam, S.; Miah, R.U.; Hossain, S.M.; Chowdhury, M.I.; Bhuiyan, A.D.; Stegnar, P.

    1993-01-01

    Uranium and thorium were determined in geological materials such as radioactive rock samples collected from the Harargaj Anticline in Moulavi Bazar. The pure instrumental neutron activation analysis (INAA) technique was used in qualitative and quantitative analysis of the rock samples for U and Th. The samples were properly prepared together with their standards and simultaneously irradiated in a neutron flux of the order of 10 12 n*cm -2 *s -1 using the TRIGA MARK II research reactor facility at the AERE, Savar, Dhaka. After activation the samples were subjected to γ-ray spectrometry using a high purity germanium detection system. As a result of the analysis, U and Th could be determined. The data are consistent with the values reported by the ground radiometric survey group for some of the samples. (author) 7 refs.; 1 fig.; 2 tabs

  7. Instrumentation

    International Nuclear Information System (INIS)

    Umminger, K.

    2008-01-01

    A proper measurement of the relevant single and two-phase flow parameters is the basis for the understanding of many complex thermal-hydraulic processes. Reliable instrumentation is therefore necessary for the interaction between analysis and experiment especially in the field of nuclear safety research where postulated accident scenarios have to be simulated in experimental facilities and predicted by complex computer code systems. The so-called conventional instrumentation for the measurement of e. g. pressures, temperatures, pressure differences and single phase flow velocities is still a solid basis for the investigation and interpretation of many phenomena and especially for the understanding of the overall system behavior. Measurement data from such instrumentation still serves in many cases as a database for thermal-hydraulic system codes. However some special instrumentation such as online concentration measurement for boric acid in the water phase or for non-condensibles in steam atmosphere as well as flow visualization techniques were further developed and successfully applied during the recent years. Concerning the modeling needs for advanced thermal-hydraulic codes, significant advances have been accomplished in the last few years in the local instrumentation technology for two-phase flow by the application of new sensor techniques, optical or beam methods and electronic technology. This paper will give insight into the current state of instrumentation technology for safety-related thermohydraulic experiments. Advantages and limitations of some measurement processes and systems will be indicated as well as trends and possibilities for further development. Aspects of instrumentation in operating reactors will also be mentioned.

  8. Patient Safety Culture Survey in Pediatric Complex Care Settings: A Factor Analysis.

    Science.gov (United States)

    Hessels, Amanda J; Murray, Meghan; Cohen, Bevin; Larson, Elaine L

    2017-04-19

    Children with complex medical needs are increasing in number and demanding the services of pediatric long-term care facilities (pLTC), which require a focus on patient safety culture (PSC). However, no tool to measure PSC has been tested in this unique hybrid acute care-residential setting. The objective of this study was to evaluate the psychometric properties of the Nursing Home Survey on Patient Safety Culture tool slightly modified for use in the pLTC setting. Factor analyses were performed on data collected from 239 staff at 3 pLTC in 2012. Items were screened by principal axis factoring, and the original structure was tested using confirmatory factor analysis. Exploratory factor analysis was conducted to identify the best model fit for the pLTC data, and factor reliability was assessed by Cronbach alpha. The extracted, rotated factor solution suggested items in 4 (staffing, nonpunitive response to mistakes, communication openness, and organizational learning) of the original 12 dimensions may not be a good fit for this population. Nevertheless, in the pLTC setting, both the original and the modified factor solutions demonstrated similar reliabilities to the published consistencies of the survey when tested in adult nursing homes and the items factored nearly identically as theorized. This study demonstrates that the Nursing Home Survey on Patient Safety Culture with minimal modification may be an appropriate instrument to measure PSC in pLTC settings. Additional psychometric testing is recommended to further validate the use of this instrument in this setting, including examining the relationship to safety outcomes. Increased use will yield data for benchmarking purposes across these specialized settings to inform frontline workers and organizational leaders of areas of strength and opportunity for improvement.

  9. Using computer-assisted survey instruments instead of paper and pencil increased completeness of self-administered sexual behavior questionnaires.

    Science.gov (United States)

    Spark, Simone; Lewis, Dyani; Vaisey, Alaina; Smyth, Eris; Wood, Anna; Temple-Smith, Meredith; Lorch, Rebecca; Guy, Rebecca; Hocking, Jane

    2015-01-01

    To compare the data quality, logistics, and cost of a self-administered sexual behavior questionnaire administered either using a computer-assisted survey instrument (CASI) or by paper and pencil in a primary care clinic. A self-administered sexual behavior questionnaire was administered to 16-29 year olds attending general practice. Questionnaires were administered by either paper and pencil (paper) or CASI. A personal digital assistant was used to self-administer the CASI. A total of 4,491 people completed the questionnaire, with 46.9% responses via CASI and 53.2% by paper. Completion of questions was greater for CASI than for paper for sexual behavior questions: number of sexual partners [odds ratio (OR), 6.85; 95% confidence interval (CI): 3.32, 14.11] and ever having had sex with a person of the same gender (OR, 2.89; 95% CI: 1.52, 5.49). The median number of questions answered was higher for CASI than for paper (17.6 vs. 17.2; P questionnaire compared with $11.83 for paper. Electronic devices using CASI are a tool that can increase participants' questionnaire responses and deliver more complete data for a sexual behavior questionnaire in primary care clinics. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. The Servant Leadership Survey: Development and Validation of a Multidimensional Measure.

    Science.gov (United States)

    van Dierendonck, Dirk; Nuijten, Inge

    2011-09-01

    PURPOSE: The purpose of this paper is to describe the development and validation of a multi-dimensional instrument to measure servant leadership. DESIGN/METHODOLOGY/APPROACH: Based on an extensive literature review and expert judgment, 99 items were formulated. In three steps, using eight samples totaling 1571 persons from The Netherlands and the UK with a diverse occupational background, a combined exploratory and confirmatory factor analysis approach was used. This was followed by an analysis of the criterion-related validity. FINDINGS: The final result is an eight-dimensional measure of 30 items: the eight dimensions being: standing back, forgiveness, courage, empowerment, accountability, authenticity, humility, and stewardship. The internal consistency of the subscales is good. The results show that the Servant Leadership Survey (SLS) has convergent validity with other leadership measures, and also adds unique elements to the leadership field. Evidence for criterion-related validity came from studies relating the eight dimensions to well-being and performance. IMPLICATIONS: With this survey, a valid and reliable instrument to measure the essential elements of servant leadership has been introduced. ORIGINALITY/VALUE: The SLS is the first measure where the underlying factor structure was developed and confirmed across several field studies in two countries. It can be used in future studies to test the underlying premises of servant leadership theory. The SLS provides a clear picture of the key servant leadership qualities and shows where improvements can be made on the individual and organizational level; as such, it may also offer a valuable starting point for training and leadership development.

  11. National Chemistry Teacher Safety Survey

    Science.gov (United States)

    Plohocki, Barbra A.

    This study evaluated the status of secondary school instructional chemistry laboratory safety using a survey instrument which focused on Teacher background Information, Laboratory Safety Equipment, Facility Safety, General Safety, and a Safety Content Knowledge Survey. A fifty question survey instrument based on recent research and questions developed by the researcher was mailed to 500 secondary school chemistry teachers who participated in the 1993 one-week Woodrow Wilson National Fellowship Foundation Chemistry Institute conducted at Princeton University, New Jersey. The data received from 303 respondents was analyzed by t tests and Analysis of Variance (ANOVA). The level of significance for the study was set at ~\\ performance on the Safety Content Knowledge Survey and secondary school chemistry teachers who have had undergraduate and/or graduate safety training and those who have not had undergraduate and/or graduate safety training. Secondary school chemistry teachers who attended school district sponsored safety inservices did not score higher on the Safety Content Knowledge Survey than teachers who did not attend school district sponsored safety inservice sessions. The type of school district (urban, suburban, or rural) had no significant correlation to the type of laboratory safety equipment found in the instructional chemistry laboratory. The certification area (chemistry or other type of certificate which may or may not include chemistry) of the secondary school teacher had no significant correlation to the type of laboratory equipment found in the instructional chemistry laboratory. Overall, this study indicated a majority of secondary school chemistry teachers were interested in attending safety workshops applicable to chemistry safety. Throughout this research project, many teachers indicated they were not adequately instructed on the collegiate level in science safety and had to rely on common sense and self-study in their future teaching careers.

  12. Development and reliability testing of a self-report instrument to measure the office layout as a correlate of occupational sitting

    Directory of Open Access Journals (Sweden)

    Duncan Mitch J

    2013-02-01

    Full Text Available Abstract Background Spatial configurations of office environments assessed by Space Syntax methodologies are related to employee movement patterns. These methods require analysis of floors plans which are not readily available in large population-based studies or otherwise unavailable. Therefore a self-report instrument to assess spatial configurations of office environments using four scales was developed. Methods The scales are: local connectivity (16 items, overall connectivity (11 items, visibility of co-workers (10 items, and proximity of co-workers (5 items. A panel cohort (N = 1154 completed an online survey, only data from individuals employed in office-based occupations (n = 307 were used to assess scale measurement properties. To assess test-retest reliability a separate sample of 37 office-based workers completed the survey on two occasions 7.7 (±3.2 days apart. Redundant scale items were eliminated using factor analysis; Chronbach’s α was used to evaluate internal consistency and test re-test reliability (retest-ICC. ANOVA was employed to examine differences between office types (Private, Shared, Open as a measure of construct validity. Generalized Linear Models were used to examine relationships between spatial configuration scales and the duration of and frequency of breaks in occupational sitting. Results The number of items on all scales were reduced, Chronbach’s α and ICCs indicated good scale internal consistency and test re-test reliability: local connectivity (5 items; α = 0.70; retest-ICC = 0.84, overall connectivity (6 items; α = 0.86; retest-ICC = 0.87, visibility of co-workers (4 items; α = 0.78; retest-ICC = 0.86, and proximity of co-workers (3 items; α = 0.85; retest-ICC = 0.70. Significant (p ≤ 0.001 differences, in theoretically expected directions, were observed for all scales between office types, except overall connectivity. Significant associations were

  13. Validation of the malaysian versions of parents and children health survey for asthma by using rasch-model.

    Science.gov (United States)

    Hussein, Maryam Se; Akram, Waqas; Mamat, Mohd Nor; Majeed, Abu Bakar Abdul; Ismail, Nahlah Elkudssiah Binti

    2015-04-01

    In recent years, health-related quality of life (HRQOL) has become an important outcome measure in epidemiologic studies and clinical trials. For patients with asthma there are many instruments but most of them have been developed in English. With the increase in research project, researchers working in other languages have two options; either to develop a new measure or to translate an already developed measure. Children Health Survey for Asthma is developed by American Academy of Paediatrics which has two versions one for the parents (CHSA) and the other for the child (CHSA-C). However, there is no Malay version of the CHSA or the CHSA-C. The aim of this study was to translate and determine the validity and reliability of the Malaysian versions of Parent and Children Health Survey for Asthma. Questionnaires were translated to Bahasa Malayu using previously established guidelines, data from 180 respondents (asthmatic children and their parent) were analysed using Rasch-Model; as, it is an approach that has been increasingly used in health field and also it explores the performance of each item rather than total set score. The internal consistency was high for the parent questionnaire (CHSA) (reliability score for persons = 0.88 and for items was 0.97), and good for child questionnaire (CHSA-C) (reliability score for persons = 0.83 and for items was 0.94). Also, this study shows that all items measure for both questionnaires (CHSA and CHSA-C) are fitted to Rasch-Model. This study produced questionnaires that are conceptually equivalent to the original, easy to understand for the children and their parents, and good in terms of internal consistency. Because of the questionnaire has two versions one for the child and the other for the parents, they could be used in clinical practice to measure the effect of asthma on the child and their families. This current research had translated two instruments to other language (BahasaMalayu) and evaluated their reliability and

  14. Portable instrumentation for quantitatively measuring radioactive surface contaminations, including 90Sr

    International Nuclear Information System (INIS)

    Brodzinski, R.L.

    1983-10-01

    In order to measure the effectiveness of decontamination efforts, a quantitative analysis of the radiocontamination is necessary, both before and after decontamination. Since it is desirable to release the decontaminated material for unrestricted use or disposal, the assay equipment must provide adequate sensitivity to measure the radioactivity at or below the release limit. In addition, the instrumentation must be capable of measuring all kinds of radiocontaminants including fission products, activation products, and transuranic materials. Finally, the survey instrumentation must be extremely versatile in order to assay the wide variety of contaminated surfaces in many environments, some of which may be extremely hostile or remote. This communication describes the development and application of portable instrumentation capable of quantitatively measuring most transuranics, activation products, and fission products, including 90 Sr, on almost any contaminated surface in nearly any location

  15. Reliability of a Retail Food Store Survey and Development of an Accompanying Retail Scoring System to Communicate Survey Findings and Identify Vendors for Healthful Food and Marketing Initiatives

    Science.gov (United States)

    Ghirardelli, Alyssa; Quinn, Valerie; Sugerman, Sharon

    2011-01-01

    Objective: To develop a retail grocery instrument with weighted scoring to be used as an indicator of the food environment. Participants/Setting: Twenty six retail food stores in low-income areas in California. Intervention: Observational. Main Outcome Measure(s): Inter-rater reliability for grocery store survey instrument. Description of store…

  16. Instrument evaluation no. 13. Nuclear enterprises portable meter type PDR

    International Nuclear Information System (INIS)

    Burgess, P.H.; Iles, W.J.

    1978-06-01

    The various radiations encountered in radiological protection cover a wide range of energies and radiation measurements have to be carried out under an equally broad spectrum of environmental conditions. This report is one of a series intended to give information on the performance characteristics of radiological protection instruments, to assist in the selection of appropriate instruments for a given purpose, to interpret the results obtained with such instruments, and, in particular, to know the likely sources and magnitude of errors that might be associated with measurements in the field. The radiation, electrical and environmental characteristics of radiation protection instruments are considered together with those aspects of the construction which make an instrument convenient for routine use. To provide consistent criteria for instrument performance, the range of tests performed on any particular class of instrument, the test methods and the criteria of acceptable performance are based broadly on the appropriate Recommendations of the International Electrotechnical Commission. The radiations in the tests are, in general, selected from the range of reference radiations for instrument calibration being drawn up by the International Standards Organisation. Normally, each report deals with the capabilities and limitations of one model of instrument and no direct comparison with other instruments intended for similar purposes is made, since the significance of particular performance characteristics largely depends on the radiations and environmental conditions in which the instrument is to be used. The results quoted here have all been obtained from tests on instruments in routine production, with the appropriate measurements being made by the NRPB. This report deals with the evaluation of Nuclear Enterprises Portable Dose Rate Meter Type PDR 2

  17. Design and validation of portable optical instrument for crop diagnose

    Science.gov (United States)

    Sun, Gang; Zheng, Wengang; Huang, Wengjiang; Wan, Huawei; Liu, Liangyun

    2005-12-01

    In this paper, a portable diagnostic instrument was designed and tested, which can measure the normalized difference vegetation index (NDVI) and structure insensitive pigment index (SIPI) of crop canopy in field. The instrument have a valid survey area of 1 m*1 m when the height between instrument and the ground was fixed to 1.3 meter The crop growth condition can be assessed based on their NDVI and SIPI values, so it will be very important for crop management to get these values. The instrument uses sunlight as its light source. There are six special different photoelectrical detectors within red, blue and near infrared bands, which are used for detecting incidence sunlight and reflex light from the canopy of crop. This optical instrument includes photoelectric detector module, signal process and A/D convert module, the data storing and transmission module and human-machine interface module. The detector is the core of the instrument which measures the spectrums at special bands. The microprocessor calculates the NDVI and SIPI value based on the A/D value. And the value can be displayed on the instrument's LCD, stored in the flash memory of instrument and can also be uploaded to PC through the PC's RS232 serial interface. The prototype was tested in the crop field at different view directions. This paper also provided the method of calibration, the results showed that the average measurement error to SIPI value of instrument was 5.25% and the average measurement error to NDVI value in vegetation-covered region is 6.40%. It reveals the on-site and non-sampling mode of crop growth monitoring by fixed on the agricultural machine traveling in the field.

  18. A framework for assessing Health Economic Evaluation (HEE) quality appraisal instruments.

    Science.gov (United States)

    Langer, Astrid

    2012-08-16

    Health economic evaluations support the health care decision-making process by providing information on costs and consequences of health interventions. The quality of such studies is assessed by health economic evaluation (HEE) quality appraisal instruments. At present, there is no instrument for measuring and improving the quality of such HEE quality appraisal instruments. Therefore, the objectives of this study are to establish a framework for assessing the quality of HEE quality appraisal instruments to support and improve their quality, and to apply this framework to those HEE quality appraisal instruments which have been subject to more scrutiny than others, in order to test the framework and to demonstrate the shortcomings of existing HEE quality appraisal instruments. To develop the quality assessment framework for HEE quality appraisal instruments, the experiences of using appraisal tools for clinical guidelines are used. Based on a deductive iterative process, clinical guideline appraisal instruments identified through literature search are reviewed, consolidated, and adapted to produce the final quality assessment framework for HEE quality appraisal instruments. The final quality assessment framework for HEE quality appraisal instruments consists of 36 items organized within 7 dimensions, each of which captures a specific domain of quality. Applying the quality assessment framework to four existing HEE quality appraisal instruments, it is found that these four quality appraisal instruments are of variable quality. The framework described in this study should be regarded as a starting point for appraising the quality of HEE quality appraisal instruments. This framework can be used by HEE quality appraisal instrument producers to support and improve the quality and acceptance of existing and future HEE quality appraisal instruments. By applying this framework, users of HEE quality appraisal instruments can become aware of methodological deficiencies

  19. Novel reconfigurable wide-beam radio interferometer for space physics instrumentation

    Science.gov (United States)

    Dekoulis, George; Honary, Farideh

    2008-07-01

    This paper describes the instrumentation design of a novel wide-beam interferometer system for radio astronomy studies. The system measures the Earth's or another planet's atmospheric layers attenuation of the highly energetic galactic electron emissions superimposed on the Cosmic Microwave Background (CMB) and other last scattering surface galactic and extragalactic radio astronomical background emissions. Right ascension coordinates are surveyed in a unique manner in terms of digital signal processing flexibility, compared to existing wide-beam instrumentations, allowing higher resolution analysis of the captured Space Physics events. The system provides a prototyping platform for other Space Physics projects, since a modular software and hardware design approach has been followed. The system is reconfigurable to meet a variety of testing scenarios.

  20. Instruments of Inquiry: Understanding the Nature and Role of Design Tools

    DEFF Research Database (Denmark)

    Dalsgaard, Peter

    2017-01-01

    Designers employ a range of tools in most design projects, yet there are few frameworks for understanding how and why they work. On the basis of a well-established school of thought, pragmatism, this paper contributes with a coherent conceptualisation of tools in design, which I label instruments...... of inquiry. This perspective underscores the crucial role that instruments play in design, and the ways in which they scaffold design creativity and exploration. In particular, it highlights that instruments not only augment our capabilities for carrying out intended actions, they also guide our perception...... and understanding of design problems and solutions. I present and discuss a framework consisting of five qualities of instruments of inquiry, which make them valuable in designerly inquiry: perception, conception, externalisation, knowing-through-action, and mediation....

  1. X-ray powder crystallography with vertex instrumentation

    International Nuclear Information System (INIS)

    Chatzisotiriou, V.; Christofis, I.; Dimitriou, N.; Karvelas, S.; Karydas, A.G.; Loukas, D.; Pavlidis, A.; Spirou, S.; Dre, C.; Haralabidis, N.; Misiakos, K.; Tsoi, E.; Perdikatsis, V.; Psycharis, V.; Terzis, A.; Turchetta, R.

    1998-01-01

    An X-ray Diffractometer for Powder Crystallography is described along with experimental results and future plans. This is an intermediate instrument toward a long linear array system. Three channels of a silicon microstrip detector, are the detecting elements in the present instrument. Each detector channel is followed by a VLSI readout chain, which consists of a charge preamplifier with pulse shaping circuitry, a discriminator, and a 16-bit counter. Control and data acquisition is performed with a custom made PC readout card. A motorized goniometer scans the angle range of interest. Calibration of the system is done with reference samples and data which are captured with a one-channel conventional NaI detector. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  2. Consistency relations in effective field theory

    Energy Technology Data Exchange (ETDEWEB)

    Munshi, Dipak; Regan, Donough, E-mail: D.Munshi@sussex.ac.uk, E-mail: D.Regan@sussex.ac.uk [Astronomy Centre, School of Mathematical and Physical Sciences, University of Sussex, Brighton BN1 9QH (United Kingdom)

    2017-06-01

    The consistency relations in large scale structure relate the lower-order correlation functions with their higher-order counterparts. They are direct outcome of the underlying symmetries of a dynamical system and can be tested using data from future surveys such as Euclid. Using techniques from standard perturbation theory (SPT), previous studies of consistency relation have concentrated on continuity-momentum (Euler)-Poisson system of an ideal fluid. We investigate the consistency relations in effective field theory (EFT) which adjusts the SPT predictions to account for the departure from the ideal fluid description on small scales. We provide detailed results for the 3D density contrast δ as well as the scaled divergence of velocity θ-bar . Assuming a ΛCDM background cosmology, we find the correction to SPT results becomes important at k ∼> 0.05 h/Mpc and that the suppression from EFT to SPT results that scales as square of the wave number k , can reach 40% of the total at k ≈ 0.25 h/Mpc at z = 0. We have also investigated whether effective field theory corrections to models of primordial non-Gaussianity can alter the squeezed limit behaviour, finding the results to be rather insensitive to these counterterms. In addition, we present the EFT corrections to the squeezed limit of the bispectrum in redshift space which may be of interest for tests of theories of modified gravity.

  3. Consistent mutational paths predict eukaryotic thermostability

    Directory of Open Access Journals (Sweden)

    van Noort Vera

    2013-01-01

    Full Text Available Abstract Background Proteomes of thermophilic prokaryotes have been instrumental in structural biology and successfully exploited in biotechnology, however many proteins required for eukaryotic cell function are absent from bacteria or archaea. With Chaetomium thermophilum, Thielavia terrestris and Thielavia heterothallica three genome sequences of thermophilic eukaryotes have been published. Results Studying the genomes and proteomes of these thermophilic fungi, we found common strategies of thermal adaptation across the different kingdoms of Life, including amino acid biases and a reduced genome size. A phylogenetics-guided comparison of thermophilic proteomes with those of other, mesophilic Sordariomycetes revealed consistent amino acid substitutions associated to thermophily that were also present in an independent lineage of thermophilic fungi. The most consistent pattern is the substitution of lysine by arginine, which we could find in almost all lineages but has not been extensively used in protein stability engineering. By exploiting mutational paths towards the thermophiles, we could predict particular amino acid residues in individual proteins that contribute to thermostability and validated some of them experimentally. By determining the three-dimensional structure of an exemplar protein from C. thermophilum (Arx1, we could also characterise the molecular consequences of some of these mutations. Conclusions The comparative analysis of these three genomes not only enhances our understanding of the evolution of thermophily, but also provides new ways to engineer protein stability.

  4. Status and needs for seismic instrumentation of structures along the Hayward fault

    Science.gov (United States)

    Kalkan, Erol; Çelebi, Mehmet

    2008-01-01

    The inventory of structures in heavily urbanized communities within the greater San Francisco (SF) Bay area that will experience strong ground motions from the rupture of the Hayward Fault includes a variety of types of recent and older structures built with a variety of materials and to different code standards. Those who remember the effects of the 1989 Loma Prieta earthquake on structures in the San Francisco Bay area also remember the collapse of one upper-deck segment of the Bay Bridge that halted transportation for approximately five weeks. In order to understand how these structures respond to earthquake motions and to improve building practices to resist these strong motions it is imperative that owners of these structures as well as governmental organizations acquire shaking response data from instrumented (or yet to be instrumented structures) during the forecast events. Within California, such data are acquired mainly by California Geological Survey and the United States Geological Survey. A small number of private owners contribute to this effort. The inventory of existing instrumented structures is much less than 0.1% of the total, and thus statistically it is not sufficient. For example, some of the existing important regular or lifeline structures are not instrumented(e.g. Bart Trans-Bay Tunnel, many segments of the Bart elevated structures in the proximity of the Hayward Fault, the yet to be completed eastern part of San Francisco Bay Bridge, Hetch-Hetchy pipeline system crossing the Hayward Fault)even though attempts and proposals have been developed to do so in the past. This paper presents a critical assessment of the status quo and the future needs for instrumentation of structures in the greater SF Bay area that includes the Hayward Fault. There are many new attempts and successes in instrumentation of structures in this region. Two successful examples are provided here, but more needs to be done. The paper does not present new research results

  5. Evaluation of a draft standard on performance specifications for health physics instrumentation - program overview

    International Nuclear Information System (INIS)

    Kathren, R.L.; Selby, J.M.; Kenoyer, J.L.; Swinth, K.L.

    1983-01-01

    The draft ANSI Standard N42.17 on performance specifications for health physics instrumentation was written in 1981 by a task group that included both manufacturers and users of these instruments as well as representation from the regulatory bodies; the second draft of this standard is currently being evaluated by Pacific Northwest Laboratory. Objectives of this project include the evaluation of the applicability and practicality of the proposed standard and the determination of the degree of conformance of a cross-section of currently available commercial instruments to the proposed standard. This standard is being tested against such instruments as ionization chambers. G.M. detectors, alpha survey meters, and neutron dose equivalent survey meters. Radiological, electrical, mechanical, safety, and environmental performance criteria are specified and tests to evaluate conformance are detailed. Specific criteria which are discussed in this draft standard include inspection tests (e.g., readout units, scaling and zero set, decontamination, moisture protection, alarm threshold, battery status indication), AC and battery power requirements, alarm reset, stability, geotropism, response time, accuracy, precision, IER, beta, and neutron energy dependence, radiation overloads, angular dependence, extracameral response, nonionizing electromagnetic radiations, magnetic fields, interfering ionizing radiations, and effect of temperature, humidity, ambient pressure, shock, and vibration. The testing procedures were developed with emphasis on the requirements found in ANSI N42.17 with additional criteria from other draft and current ANSI and IEC standards

  6. Instrumental interaction

    OpenAIRE

    Luciani , Annie

    2007-01-01

    International audience; The expression instrumental interaction as been introduced by Claude Cadoz to identify a human-object interaction during which a human manipulates a physical object - an instrument - in order to perform a manual task. Classical examples of instrumental interaction are all the professional manual tasks: playing violin, cutting fabrics by hand, moulding a paste, etc.... Instrumental interaction differs from other types of interaction (called symbolic or iconic interactio...

  7. SEQUenCE: a service user-centred quality of care instrument for mental health services.

    Science.gov (United States)

    Hester, Lorraine; O'Doherty, Lorna Jane; Schnittger, Rebecca; Skelly, Niamh; O'Donnell, Muireann; Butterly, Lisa; Browne, Robert; Frorath, Charlotte; Morgan, Craig; McLoughlin, Declan M; Fearon, Paul

    2015-08-01

    To develop a quality of care instrument that is grounded in the service user perspective and validate it in a mental health service. The instrument (SEQUenCE (SErvice user QUality of CarE)) was developed through analysis of focus group data and clinical practice guidelines, and refined through field-testing and psychometric analyses. All participants were attending an independent mental health service in Ireland. Participants had a diagnosis of bipolar affective disorder (BPAD) or a psychotic disorder. Twenty-nine service users participated in six focus group interviews. Seventy-one service users participated in field-testing: 10 judged the face validity of an initial 61-item instrument; 28 completed a revised 52-item instrument from which 12 items were removed following test-retest and convergent validity analyses; 33 completed the resulting 40-item instrument. Test-retest reliability, internal consistency and convergent validity of the instrument. The final instrument showed acceptable test-retest reliability at 5-7 days (r = 0.65; P Service Satisfaction Scale (r = 0.84, P internal consistency (Cronbach's alpha = 0.87). SEQUenCE is a valid, reliable scale that is grounded in the service user perspective and suitable for routine use. It may serve as a useful tool in individual care planning, service evaluation and research. The instrument was developed and validated with service users with a diagnosis of either BPAD or a psychotic disorder; it does not yet have established external validity for other diagnostic groups. © The Author 2015. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.

  8. [Development of an evaluation instrument for service quality in nursing homes].

    Science.gov (United States)

    Lee, Jia; Ji, Eun Sun

    2011-08-01

    The purposes of this study were to identify the factors influencing service quality in nursing homes, and to develop an evaluation instrument for service quality. A three-phase process was employed for the study. 1) The important factors to evaluate the service quality in nursing homes were identified through a literature review, panel discussion and focus group interview, 2) the evaluation instrument was developed, and 3) validity and reliability of the study instrument were tested by factor analysis, Pearson correlation coefficient, Cronbach's α and Cohen's Kappa. Factor analysis showed that the factors influencing service quality in nursing homes were healthcare, diet/assistance, therapy, environment and staff. To improve objectivity of the instrument, quantitative as well as qualitative evaluation approaches were adopted. The study instrument was developed with 30 items and showed acceptable construct validity. The criterion-related validity was a Pearson correlation coefficient of .85 in 151 care facilities. The internal consistency was Cronbach's α=.95. The instrument has acceptable validity and a high degree of reliability. Staff in nursing homes can continuously improve and manage their services using the results of the evaluation instrument.

  9. Planck 2013 results. XXXI. Consistency of the Planck data

    CERN Document Server

    Ade, P A R; Ashdown, M; Aumont, J; Baccigalupi, C; Banday, A.J; Barreiro, R.B; Battaner, E; Benabed, K; Benoit-Levy, A; Bernard, J.P; Bersanelli, M; Bielewicz, P; Bond, J.R; Borrill, J; Bouchet, F.R; Burigana, C; Cardoso, J.F; Catalano, A; Challinor, A; Chamballu, A; Chiang, H.C; Christensen, P.R; Clements, D.L; Colombi, S; Colombo, L.P.L; Couchot, F; Coulais, A; Crill, B.P; Curto, A; Cuttaia, F; Danese, L; Davies, R.D; Davis, R.J; de Bernardis, P; de Rosa, A; de Zotti, G; Delabrouille, J; Desert, F.X; Dickinson, C; Diego, J.M; Dole, H; Donzelli, S; Dore, O; Douspis, M; Dupac, X; Ensslin, T.A; Eriksen, H.K; Finelli, F; Forni, O; Frailis, M; Fraisse, A A; Franceschi, E; Galeotta, S; Ganga, K; Giard, M; Gonzalez-Nuevo, J; Gorski, K.M.; Gratton, S.; Gregorio, A; Gruppuso, A; Gudmundsson, J E; Hansen, F.K; Hanson, D; Harrison, D; Henrot-Versille, S; Herranz, D; Hildebrandt, S.R; Hivon, E; Hobson, M; Holmes, W.A.; Hornstrup, A; Hovest, W.; Huffenberger, K.M; Jaffe, T.R; Jaffe, A.H; Jones, W.C; Keihanen, E; Keskitalo, R; Knoche, J; Kunz, M; Kurki-Suonio, H; Lagache, G; Lahteenmaki, A; Lamarre, J.M; Lasenby, A; Lawrence, C.R; Leonardi, R; Leon-Tavares, J; Lesgourgues, J; Liguori, M; Lilje, P.B; Linden-Vornle, M; Lopez-Caniego, M; Lubin, P.M; Macias-Perez, J.F; Maino, D; Mandolesi, N; Maris, M; Martin, P.G; Martinez-Gonzalez, E; Masi, S; Matarrese, S; Mazzotta, P; Meinhold, P.R; Melchiorri, A; Mendes, L; Mennella, A; Migliaccio, M; Mitra, S; Miville-Deschenes, M.A; Moneti, A; Montier, L; Morgante, G; Mortlock, D; Moss, A; Munshi, D; Murphy, J A; Naselsky, P; Nati, F; Natoli, P; Norgaard-Nielsen, H.U; Noviello, F; Novikov, D; Novikov, I; Oxborrow, C.A; Pagano, L; Pajot, F; Paoletti, D; Partridge, B; Pasian, F; Patanchon, G; Pearson, D; Pearson, T.J; Perdereau, O; Perrotta, F; Piacentini, F; Piat, M; Pierpaoli, E; Pietrobon, D; Plaszczynski, S; Pointecouteau, E; Polenta, G; Ponthieu, N; Popa, L; Pratt, G.W; Prunet, S; Puget, J.L; Rachen, J.P; Reinecke, M; Remazeilles, M; Renault, C; Ricciardi, S.; Ristorcelli, I; Rocha, G.; Roudier, G; Rubino-Martin, J.A; Rusholme, B; Sandri, M; Scott, D; Stolyarov, V; Sudiwala, R; Sutton, D; Suur-Uski, A.S; Sygnet, J.F; Tauber, J.A; Terenzi, L; Toffolatti, L; Tomasi, M; Tristram, M; Tucci, M; Valenziano, L; Valiviita, J; Van Tent, B; Vielva, P; Villa, F; Wade, L.A; Wandelt, B.D; Wehus, I K; White, S D M; Yvon, D; Zacchei, A; Zonca, A

    2014-01-01

    The Planck design and scanning strategy provide many levels of redundancy that can be exploited to provide tests of internal consistency. One of the most important is the comparison of the 70 GHz (amplifier) and 100 GHz (bolometer) channels. Based on different instrument technologies, with feeds located differently in the focal plane, analysed independently by different teams using different software, and near the minimum of diffuse foreground emission, these channels are in effect two different experiments. The 143 GHz channel has the lowest noise level on Planck, and is near the minimum of unresolved foreground emission. In this paper, we analyse the level of consistency achieved in the 2013 Planck data. We concentrate on comparisons between the 70, 100, and 143 GHz channel maps and power spectra, particularly over the angular scales of the first and second acoustic peaks, on maps masked for diffuse Galactic emission and for strong unresolved sources. Difference maps covering angular scales from 8°...

  10. Trace Gas Measurements from the GeoTASO and GCAS Airborne Instruments: An Instrument and Algorithm Test-Bed for Air Quality Observations from Geostationary Orbit

    Science.gov (United States)

    Nowlan, C. R.; Liu, X.; Janz, S. J.; Leitch, J. W.; Al-Saadi, J. A.; Chance, K.; Cole, J.; Delker, T.; Follette-Cook, M. B.; Gonzalez Abad, G.; Good, W. S.; Kowalewski, M. G.; Loughner, C.; Pickering, K. E.; Ruppert, L.; Soo, D.; Szykman, J.; Valin, L.; Zoogman, P.

    2016-12-01

    The Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) and the GEO-CAPE Airborne Simulator (GCAS) instruments are pushbroom sensors capable of making remote sensing measurements of air quality and ocean color. Originally developed as test-bed instruments for the Geostationary Coastal and Air Pollution Events (GEO-CAPE) decadal survey, these instruments are now also part of risk reduction for the upcoming Tropospheric Emissions: Monitoring of Pollution (TEMPO) and Geostationary Environment Monitoring Spectrometer (GEMS) geostationary satellite missions, and will provide validation capabilities after the satellite instruments are in orbit. GeoTASO and GCAS flew on two different aircraft in their first intensive air quality field campaigns during the DISCOVER-AQ missions over Texas in 2013 and Colorado in 2014. GeoTASO was also deployed in 2016 during the KORUS-AQ field campaign to make measurements of trace gases and aerosols over Korea. GeoTASO and GCAS collect spectra of backscattered solar radiation in the UV and visible that can be used to derive 2-D maps of trace gas columns below the aircraft at spatial resolutions on the order of 250 x 500 m. We present spatially resolved maps of trace gas retrievals of ozone, nitrogen dioxide, formaldehyde and sulfur dioxide over urban areas and power plants from flights during the field campaigns, and comparisons with data from ground-based spectrometers, in situ monitoring instruments, and satellites.

  11. Consumer preferences for reduced packaging under economic instruments and recycling policy.

    Science.gov (United States)

    Yamaguchi, Keiko; Takeuchi, Kenji

    2016-02-01

    This study was conducted using a web-based survey and bidding game in contingent valuation method to evaluate consumer preferences for packaging with less material. Results revealed that people who live in a municipality implementing unit-based pricing of waste have a higher willingness-to-pay (WTP) for a product. Economic instruments can affect the purchase of products with reduced packaging because a higher disposal cost increases the attractiveness of source reduction. However, unit-based pricing combined with plastic separation for recycling reduces WTP. This result suggests that recycling policy weakens the effect of economic instruments on source reduction of waste. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Instrumentation development

    International Nuclear Information System (INIS)

    Ubbes, W.F.; Yow, J.L. Jr.

    1988-01-01

    Instrumentation is developed for the Civilian Radioactive Waste Management Program to meet several different (and sometimes conflicting) objectives. This paper addresses instrumentation development for data needs that are related either directly or indirectly to a repository site, but does not touch on instrumentation for work with waste forms or other materials. Consequently, this implies a relatively large scale for the measurements, and an in situ setting for instrument performance. In this context, instruments are needed for site characterization to define phenomena, develop models, and obtain parameter values, and for later design and performance confirmation testing in the constructed repository. The former set of applications is more immediate, and is driven by the needs of program design and performance assessment activities. A host of general technical and nontechnical issues have arisen to challenge instrumentation development. Instruments can be classed into geomechanical, geohydrologic, or other specialty categories, but these issues cut across artificial classifications. These issues are outlined. Despite this imposing list of issues, several case histories are cited to evaluate progress in the area

  13. Instrumentation

    International Nuclear Information System (INIS)

    Decreton, M.

    2002-01-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described

  14. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  15. Cryogenic instrumentation needs in the controlled thermonuclear research program

    International Nuclear Information System (INIS)

    Walstrom, P.L.

    1976-01-01

    The magnet development effort for the controlled thermonuclear research program will require extensive testing of superconducting coils at various sizes from small-scale models to full-size prototypes. Extensive use of diagnostic instrumentation will be required and to make detailed comparisons of predicted and actual performance in magnet tests and to monitor the test facility for incipient failure modes. At later stages of the program, cryogenic instrumentation will be required to monitor magnet system performance in fusion power reactors. Measured quantities may include temperature, strain, deflection, coil resistance, helium coolant pressure and flow, current, voltages, etc. The test environment, which includes high magnetic fields (up to 8-10 T) and low temperature, makes many commercial measuring devices inoperative or at least inaccurate. In order to ensure reliable measurements, careful screening of commercial devices for performance in the test environment will be required. A survey of potentially applicable instrumentation is presented along with available information on operation in the test environment based on experimental data or on analysis of the physical characteristics of the device. Areas where further development work is needed are delineated

  16. The Student Actions Coding Sheet (SACS): An instrument for illuminating the shifts toward student-centered science classrooms

    Science.gov (United States)

    Erdogan, Ibrahim; Campbell, Todd; Hashidah Abd-Hamid, Nor

    2011-07-01

    This study describes the development of an instrument to investigate the extent to which student-centered actions are occurring in science classrooms. The instrument was developed through the following five stages: (1) student action identification, (2) use of both national and international content experts to establish content validity, (3) refinement of the item pool based on reviewer comments, (4) pilot testing of the instrument, and (5) statistical reliability and item analysis leading to additional refinement and finalization of the instrument. In the field test, the instrument consisted of 26 items separated into four categories originally derived from student-centered instruction literature and used by the authors to sort student actions in previous research. The SACS was administered across 22 Grade 6-8 classrooms by 22 groups of observers, with a total of 67 SACS ratings completed. The finalized instrument was found to be internally consistent, with acceptable estimates from inter-rater intraclass correlation reliability coefficients at the p Observation Protocol. Based on the analyses completed, the SACS appears to be a useful instrument for inclusion in comprehensive assessment packages for illuminating the extent to which student-centered actions are occurring in science classrooms.

  17. Evaluating Temporal Consistency in Marine Biodiversity Hotspots.

    Science.gov (United States)

    Piacenza, Susan E; Thurman, Lindsey L; Barner, Allison K; Benkwitt, Cassandra E; Boersma, Kate S; Cerny-Chipman, Elizabeth B; Ingeman, Kurt E; Kindinger, Tye L; Lindsley, Amy J; Nelson, Jake; Reimer, Jessica N; Rowe, Jennifer C; Shen, Chenchen; Thompson, Kevin A; Heppell, Selina S

    2015-01-01

    With the ongoing crisis of biodiversity loss and limited resources for conservation, the concept of biodiversity hotspots has been useful in determining conservation priority areas. However, there has been limited research into how temporal variability in biodiversity may influence conservation area prioritization. To address this information gap, we present an approach to evaluate the temporal consistency of biodiversity hotspots in large marine ecosystems. Using a large scale, public monitoring dataset collected over an eight year period off the US Pacific Coast, we developed a methodological approach for avoiding biases associated with hotspot delineation. We aggregated benthic fish species data from research trawls and calculated mean hotspot thresholds for fish species richness and Shannon's diversity indices over the eight year dataset. We used a spatial frequency distribution method to assign hotspot designations to the grid cells annually. We found no areas containing consistently high biodiversity through the entire study period based on the mean thresholds, and no grid cell was designated as a hotspot for greater than 50% of the time-series. To test if our approach was sensitive to sampling effort and the geographic extent of the survey, we followed a similar routine for the northern region of the survey area. Our finding of low consistency in benthic fish biodiversity hotspots over time was upheld, regardless of biodiversity metric used, whether thresholds were calculated per year or across all years, or the spatial extent for which we calculated thresholds and identified hotspots. Our results suggest that static measures of benthic fish biodiversity off the US West Coast are insufficient for identification of hotspots and that long-term data are required to appropriately identify patterns of high temporal variability in biodiversity for these highly mobile taxa. Given that ecological communities are responding to a changing climate and other

  18. Quality appraisal of generic self-reported instruments measuring health-related productivity changes: a systematic review

    Science.gov (United States)

    2014-01-01

    Background Health impairments can result in disability and changed work productivity imposing considerable costs for the employee, employer and society as a whole. A large number of instruments exist to measure health-related productivity changes; however their methodological quality remains unclear. This systematic review critically appraised the measurement properties in generic self-reported instruments that measure health-related productivity changes to recommend appropriate instruments for use in occupational and economic health practice. Methods PubMed, PsycINFO, Econlit and Embase were systematically searched for studies whereof: (i) instruments measured health-related productivity changes; (ii) the aim was to evaluate instrument measurement properties; (iii) instruments were generic; (iv) ratings were self-reported; (v) full-texts were available. Next, methodological quality appraisal was based on COSMIN elements: (i) internal consistency; (ii) reliability; (iii) measurement error; (iv) content validity; (v) structural validity; (vi) hypotheses testing; (vii) cross-cultural validity; (viii) criterion validity; and (ix) responsiveness. Recommendations are based on evidence syntheses. Results This review included 25 articles assessing the reliability, validity and responsiveness of 15 different generic self-reported instruments measuring health-related productivity changes. Most studies evaluated criterion validity, none evaluated cross-cultural validity and information on measurement error is lacking. The Work Limitation Questionnaire (WLQ) was most frequently evaluated with moderate respectively strong positive evidence for content and structural validity and negative evidence for reliability, hypothesis testing and responsiveness. Less frequently evaluated, the Stanford Presenteeism Scale (SPS) showed strong positive evidence for internal consistency and structural validity, and moderate positive evidence for hypotheses testing and criterion validity. The

  19. Instrumentation for medical diagnosis and research with radionuclides in the developing countries. Progress report, June 1, 1977--May 31, 1978

    Energy Technology Data Exchange (ETDEWEB)

    Dudley, R.A.

    1978-07-01

    This project seeks to bring about a more effective use of nuclear instruments in medical applications of radionuclides in developing countries by facilitating selection of appropriate applications, by stimulating the design of instruments capable of performing these applications satisfactorily under the conditions prevailing, and by encouraging improved maintenance. A pilot cost-effectiveness analysis of nuclear medicine applications has been completed, suggesting two topics for further investigation and demonstrating that such analyses can yield useful insights. In the realm of instrument design, we have further developed our prototype well scintillation counter, provided three such instruments for tests in the field, and encouraged its production by others. In addition, we have examined design issues for liquid scintillation counters, radiorespirometry counting devices, whole-body counters, and electrical power supplies. We have completed a survey of maintenance in 8 countries in Southeast Asia and are analyzing the results. Preparations are underway for surveys in three further regions.

  20. Availability and accessibility of e-books in Nigerian libraries: a survey

    African Journals Online (AJOL)

    This paper investigates availability and accessibility of e-books in Nigeria Libraries. A social survey method of research was adopted for the study and the questionnaire as a research instrument was used. A systematic random sampling technique was used to determine respondents in the survey. The result shows that ...