WorldWideScience

Sample records for survey instrument comprised

  1. Operating device for laparoscopic surgery training instrument, comprises body movable over flat surface and used to supply movement signals to instrument

    NARCIS (Netherlands)

    Wentink, M.

    2002-01-01

    The operating device (1) comprises a body (2) which can be moved over the surface of a flat panel or tabletop (3) and is provided with a displacement sensor for converting a displacement of the body over this surface into electric signals, which are supplied to the instrument via a connecting cable

  2. Development of the physician satisfaction survey instrument.

    Science.gov (United States)

    Soo Hoo, W E; Ramer, L

    1998-01-01

    Continuous quality improvement (CQI) activities depend on valid and reliable instruments to generate data. An evaluation of internal and external customer satisfaction is one of the pillars of the CQI process. This article describes the development of a valid and reliable instrument for measuring physicians' satisfaction with the orthopedic nursing units at a major medical trauma center. The physician satisfaction survey instrument was found to be internally consistent (alpha = .95). Confirmatory factor analysis revealed that 68% of the variance in physician satisfaction scores (eigenvalue = 8.14) was explained by using a single-factor model.

  3. Star Formation & Stellar Evolution: Future Surveys & Instrumentation

    CERN Document Server

    Evans, C J

    2015-01-01

    The next generation of multi-object spectrographs (MOS) will deliver comprehensive surveys of the Galaxy, Magellanic Clouds and nearby dwarfs. These will provide us with the vast samples, spanning the full extent of the Hertzsprung-Russell diagram, that are needed to explore the chemistry, history and dynamics of their host systems. Further ahead, the Extremely Large Telescopes (ELTs) will have sufficient sensitivity and angular resolution to extend stellar spectroscopy well beyond the Local Group, opening-up studies of the chemical evolution of galaxies across a broad range of galaxy types and environments. In this contribution I briefly reflect on current and future studies of stellar populations, and introduce plans for the MOSAIC instrument for the European ELT.

  4. Measuring teamwork in health care settings: a review of survey instruments.

    Science.gov (United States)

    Valentine, Melissa A; Nembhard, Ingrid M; Edmondson, Amy C

    2015-04-01

    Teamwork in health care settings is widely recognized as an important factor in providing high-quality patient care. However, the behaviors that comprise effective teamwork, the organizational factors that support teamwork, and the relationship between teamwork and patient outcomes remain empirical questions in need of rigorous study. To identify and review survey instruments used to assess dimensions of teamwork so as to facilitate high-quality research on this topic. We conducted a systematic review of articles published before September 2012 to identify survey instruments used to measure teamwork and to assess their conceptual content, psychometric validity, and relationships to outcomes of interest. We searched the ISI Web of Knowledge database, and identified relevant articles using the search terms team, teamwork, or collaboration in combination with survey, scale, measure, or questionnaire. We found 39 surveys that measured teamwork. Surveys assessed different dimensions of teamwork. The most commonly assessed dimensions were communication, coordination, and respect. Of the 39 surveys, 10 met all of the criteria for psychometric validity, and 14 showed significant relationships to nonself-report outcomes. Evidence of psychometric validity is lacking for many teamwork survey instruments. However, several psychometrically valid instruments are available. Researchers aiming to advance research on teamwork in health care should consider using or adapting one of these instruments before creating a new one. Because instruments vary considerably in the behavioral processes and emergent states of teamwork that they capture, researchers must carefully evaluate the conceptual consistency between instrument, research question, and context.

  5. Higher Education and Students with Orthopedic Disabilities: A Survey Instrument.

    Science.gov (United States)

    Singh, Delar K.

    A survey instrument is presented that was used in a national survey of 160 colleges and universities to explore facilities and services to students with orthopedic disabilities. The survey contains 33 items that focus on the following areas: structural accessibility, academic accessibility, dorm-living, and recreational opportunities. The total…

  6. Urbis: Instrument ofr local environmental survey

    NARCIS (Netherlands)

    Borst, H.C.

    2000-01-01

    TNO has developed a GIS based instrument, named Urbis, which makes it possible to assess the noise situation in a municipality or region as a whole, with a high level of detail. On the basis of activity or emission data (road-traffic intensities, acoustical reports, etc.), noise loads are calculated

  7. Development of an RDECOM Workforce Motivational Survey Instrument

    Science.gov (United States)

    2016-09-01

    compensation and workplace environment structure to motivate the target generational workforce demographic to improve productivity. The deliverables from this...factors. We developed a closed-loop survey instrument and analysis methodology to identify distinct generational workforce motivational factors. Nine...United States Army Research Development and Engineering Command (RDECOM) supervisory engineers, General Schedule (GS) 14 and 15, reviewed the survey

  8. Inertial instrument system for aerial surveying

    Science.gov (United States)

    Brown, R.H.; Chapman, W.H.; Hanna, W.F.; Mongan, C.E.; Hursh, J.W.

    1985-01-01

    An inertial guidance system for aerial surveying has been developed under contract to the U.S. Geological Survey. This prototype system, known as the aerial profiling of terrain (APT) system, is designed to determine continuously the positions of points along an aircraft flight path, or the underlying terrain profile, to an accuracy of + or - 0.5 ft (15 cm) vertically and + or - 2 ft (61 cm) horizontally. The system 's objective thus is to accomplish, from a fixed-wing aircraft, what would traditionally be accomplished from ground-based topographic surveys combined with aerial photography and photogrammetry. The two-part strategy for measuring the terrain profile entails: (1) use of an inertial navigator for continuous determination of the three-coordinate position of the aircraft, and (2) use of an eye-safe pulsed laser profiler for continuous measurement of the vertical distance from aircraft to land surface, so that the desired terrain profile can then be directly computed. The APT system, installed in a DeHavilland Twin Otter aircraft, is typically flown at a speed of 115 mph (105 knots) at an altitude of 2,000 ft (610 m) above the terrain. Performance-evaluation flights have shown that the vertical and horizontal accuracy specifications are met. (USGS)

  9. Survey Instrument Validity Part I: Principles of Survey Instrument Development and Validation in Athletic Training Education Research

    Science.gov (United States)

    Burton, Laura J.; Mazerolle, Stephanie M.

    2011-01-01

    Context: Instrument validation is an important facet of survey research methods and athletic trainers must be aware of the important underlying principles. Objective: To discuss the process of survey development and validation, specifically the process of construct validation. Background: Athletic training researchers frequently employ the use of…

  10. Instrumentation

    Institute of Scientific and Technical Information of China (English)

    2015-01-01

    Journal Scope:Instrumentation is a high quality open access peer reviewed research journal.Authors are solicited to contribute to these journals by submitting articles that illustrate most up-to-date research results,projects,surveying works and industrial experiences that describe significant advances in the instrumental science.The mission of the Instrumentation is

  11. [French residents' training in instrumental deliveries: A national survey].

    Science.gov (United States)

    Saunier, C; Raimond, E; Dupont, A; Pelissier, A; Bonneau, S; Gabriel, R; Graesslin, O

    2016-11-01

    To evaluate French residents in Obstetrics and Gynaecology's training in instrumental deliveries in 2015. We conducted a national descriptive survey among 758 residents between December 2014 and January 2015. Respondents were invited by email to specify their University Hospital, their current university term, the number of instrumental deliveries performed by vacuum extractor, forceps or spatulas, and whether they made systematic ultrasound exams before performing the extraction. Response rate was 34.7 % (n=263). There were important differences between regions in terms of type of instruments used. Vacuum extractor was the most commonly used instrument for instrumental deliveries by French residents (56.9 %), more than forceps (25.2 %) and spatulas (17.9 %). At the end of the residency, all the residents had been trained in instrumental deliveries with at least two instruments. The training of difficult techniques as well as their perfect control is required for instrumental deliveries. Yet, we are forced to note that there are substantial differences in the French residents' training in instrumental deliveries depending on their region. So, teaching at least two techniques seems essential as well as improving the training capacities and standardizing practices. A greater systematization of the teaching of the mechanics and obstetric techniques might be a solution to be considered too. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  12. Applications of Calendar Instruments in Social Surveys: a review

    NARCIS (Netherlands)

    Glasner, T.J.; Vaart, van der W.

    2009-01-01

    Retrospective reports in survey interviews and questionnaires are subject to many types of recall error, which affect completeness, consistency, and dating accuracy. Concerns about this problem have led to the development of so-called calendar instruments, or timeline techniques. These aided recall

  13. The Undergraduate Instrumental Analysis Course: A Survey of Available Equipment.

    Science.gov (United States)

    Leggett, D. J.

    1981-01-01

    Reports results of a survey in which 110 universities were selected to respond to questions regarding approximate age and cost of the instruments used in three major areas: separations, spectroscopy, and electroanalysis. Respondents (N=41) also indicated which pieces of equipment were used in undergraduate courses or were used for research. (CS)

  14. Technical evaluation of available state of Nevada survey instruments

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-02-01

    Argonne National Laboratory (ANL) is reviewing the survey research studies completed by Mountain West Research (1987-1989) for the state of Nevada`s Nuclear Waste Project Office. In this research, 14 survey instruments were used to seek data on whether perceptions of risk could be associated with the possible siting of a high-level radioactive waste repository in Nevada and could be a dominant source of potential, significant, adverse economic impacts. This report presents results from phase 1 of the review, in which ANL contracted with the National Opinion Research Center (NORC) at the University of Chicago to evaluate the technical merits of the nine survey instruments that ANL had been able to acquire. The scope of NORC`s work was limited to rating the questions and stating their strengths and weaknesses. NORC concluded that the surveys could provide valuable data about risk perceptions and potential behavioral responses. NORC identified a few minor problems with a number of questions and the calculated response rates but claimed these problems would probably not have any major biasing effect. The NORC evaluation would have been more complete if the terms used in the questionnaires had been defined, all survey instruments had been acquired, and all data had been made available to the public.

  15. Antisocial sport behaviors survey: instrument development and initial validation.

    Science.gov (United States)

    Kaye, Miranda P; Hoar, Sharleen

    2015-04-01

    The development of a self-report instrument to measure antisocial sport behavior, labeled the Antisocial Sport Behavior Survey (ASBS), among large and diverse samples of athletes is reported. Grounded in the social cognitive theory of moral thought and action (Bandura, 1991) and interpersonal theory (Horowitz, 2004), this instrument was developed and tested in accordance with the traditions of construct validity and classical test theory (Gehlback & Brinkworth, 2011). In Phase 1, 272 college-aged competitive sport participants confirmed a theoretical structure of antisocial sport behavior including eight factors (hypercompetitive, intimidating, antagonistic, disrespectful, exploitable, overly accommodating, abetting, and melodramatic). Phase 2 reports on item development and the response structure of the instrument. In Phase 3, evidence of structural validity and external validity for the ASBS was established with 340 college-aged competitive sport participants. The ASBS presents as a promising new instrument to advance understanding of antisocial sport behavior acts committed by competitive athletes.

  16. Instrumentation

    Institute of Scientific and Technical Information of China (English)

    2016-01-01

    Journal Scope:Instrumentation is a high quality open access peer reviewed research journal.Authors are solicited to contribute to these journals by submitting articles that illustrate most up-to-date research results,projects,surveying works and industrial experiences that describe significant advances in the instrumental science.The mission of the Instrumentation is to provide a platform for the researchers,academicians,

  17. Instrument and Survey Analysis Technical Report: Program Implementation Survey. Technical Report #1112

    Science.gov (United States)

    Alonzo, Julie; Tindal, Gerald

    2011-01-01

    This technical document provides guidance to educators on the creation and interpretation of survey instruments, particularly as they relate to an analysis of program implementation. Illustrative examples are drawn from a survey of educators related to the use of the easyCBM learning system. This document includes specific sections on…

  18. Human factors survey of advanced instrumentation and controls

    Energy Technology Data Exchange (ETDEWEB)

    Carter, R.J.

    1989-01-01

    A survey oriented towards identifying the human factors issues in regard to the use of advanced instrumentation and controls (I C) in the nuclear industry was conducted. A number of United States (US) and Canadian nuclear vendors and utilities were participants in the survey. Human factors items, subsumed under the categories of computer-generated displays (CGD), controls, organizational support, training, and related topics, were discussed. The survey found the industry to be concerned about the human factors issues related to the implementation of advanced I C. Fifteen potential human factors problems were identified. They include: the need for an advanced I C guideline equivalent to NUREG-0700; a role change in the control room from operator to supervisor; information overload; adequacy of existing training technology for advanced I C; and operator acceptance and trust. 11 refs., 1 tab.

  19. Weak Lensing from Space I: Instrumentation and Survey Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Rhodes, Jason; Refregier, Alexandre; Massey, Richard; Albert, Justin; Bacon, David; Bernstein, Gary; Ellis, Richard; Jain, Bhuvnesh; Kim, Alex; Lampton, Mike; McKay, Tim; Akerlof, C.; Aldering, G.; Amanullah, R.; Astier, P.; Barrelet, E.; Bebek, C.; Bergstrom, L.; Bercovitz, J.; Bester, M.; Bonissent, A.; Bower, C.; Carithers, W.; Commins, E.; Day, C.; Deustua, S.; DiGennaro, R.; Ealet, A.; Eriksson, M.; Fruchter, A.; Genat, J.-F.; Goldhaber, G.; Goobar, A.; Groom, D.; Harris, S.; Harvey, P.; Heetderks, H.; Holland, S.; Huterer, D.; Karcher, A.; Kolbe, W.; Kreiger, B.; Lafever, R.; Lamoureux, J.; Levi, M.; Devin, D.; Linder, E.; Loken, S.; Malina, R.; McKee, S.; Miquel, R.; Mortsell, E.; Mostek, N.; Mufson, S.; Musser, J.; Nugent, P.; Oluseyi, H.; Pain, R.; Palaio, N.; Pankow, D.; Perlmutter, S.; Pratt, R.; Prieto, E.; Robinson, K.; Roe, N.; Sholl, M.; Schubnell, M.; Smadja, G.; Smoot, G.; Spadafora, A.; Tarle, G.; Tomasch, A.; von der Lippe, H.; Vincent, D.; Walder, J.-P.; Wang, G.

    2003-04-23

    A wide field space-based imaging telescope is necessary to fully exploit the technique of observing dark matter via weak gravitational lensing. This first paper in a three part series outlines the survey strategies and relevant instrumental parameters for such a mission. As a concrete example of hardware design, we consider the proposed Supernova/Acceleration Probe (SNAP). Using SNAP engineering models, we quantify the major contributions to this telescope's Point Spread Function (PSF). These PSF contributions are relevant to any similar wide field space telescope. We further show that the PSF of SNAP or a similar telescope will be smaller than current ground-based PSFs, and more isotropic and stable over time than the PSF of the Hubble Space Telescope. We outline survey strategies for two different regimes - a ''wide'' 300 square degree survey and a ''deep'' 15 square degree survey that will accomplish various weak lensing goals including statistical studies and dark matter mapping.

  20. Lateral Violence in Nursing Survey: Instrument Development and Validation

    Directory of Open Access Journals (Sweden)

    Lynne S. Nemeth

    2017-07-01

    Full Text Available An examination of the psychometric properties of the Lateral Violence in Nursing Survey (LVNS, an instrument previously developed to measure the perceived incidence and severity of lateral violence (LV in the nursing workplace, was carried out. Conceptual clustering and principal components analysis were used with survey responses from 663 registered nurses and ancillary nursing staff in a southeastern tertiary care medical center. Where appropriate, Cronbach’s alpha (α evaluated internal consistency. The prevalence/severity of lateral violence items constitute two distinct subscales (LV by self and others with Cronbach’s alpha of 0.74 and 0.86, respectively. The items asking about potential causes of LV are unidimensional and internally consistent (alpha = 0.77 but there is no conceptually coherent theme underlying the various causes. Respondents rating a potential LV cause as “major” scored higher on both prevalence/severity subscales than those rating it a “minor” cause or not a cause. Subsets of items on the LVNS are internally reliable, supporting construct validity. Revisions of the original LVNS instrument will improve its use in future work.

  1. Instrumentation

    Institute of Scientific and Technical Information of China (English)

    2015-01-01

    Journal Scope:Instrumentation is a high quality open access peer reviewed research journal,Authors are solicited to contribute to these journals by submitting articles that illustrate most up-to-date research results,projects,surveying works and industrial

  2. Star Formation and Stellar Evolution: Future Surveys and Instrumentation

    Science.gov (United States)

    Evans, C. J.

    2016-10-01

    The next generation of multi-object spectrographs (MOS) will deliver comprehensive surveys of the Galaxy, Magellanic Clouds and nearby dwarfs. These will provide us with the vast samples, spanning the full extent of the Hertzsprung-Russell diagram, that are needed to explore the chemistry, history and dynamics of their host systems. Further ahead, the Extremely Large Telescopes (ELTs) will have sufficient sensitivity and angular resolution to extend stellar spectroscopy well beyond the Local Group, opening-up studies of the chemical evolution of galaxies across a broad range of galaxy types and environments. In this contribution I briefly reflect on current and future studies of stellar populations, and introduce plans for the MOSAIC instrument for the European ELT.

  3. New hydrologic instrumentation in the U.S. Geological Survey

    Science.gov (United States)

    Latkovich, V.J.; Shope, W.G.; ,

    1991-01-01

    New water-level sensing and recording instrumentation is being used by the U.S. Geological Survey for monitoring water levels, stream velocities, and water-quality characteristics. Several of these instruments are briefly described. The Basic Data Recorder (BDR) is an electronic data logger, that interfaces to sensor systems through a serial-digital interface standard (SDI-12), which was proposed by the data-logger industry; the Incremental Shaft Encoder is an intelligent water-level sensor, which interfaces to the BDR through the SDI-12; the Pressure Sensor is an intelligent, nonsubmersible pressure sensor, which interfaces to the BDR through the SDI-12 and monitors water levels from 0 to 50 feet; the Ultrasonic Velocity Meter is an intelligent, water-velocity sensor, which interfaces to the BDR through the SDI-12 and measures the velocity across a stream up to 500 feet in width; the Collapsible Hand Sampler can be collapsed for insertion through holes in the ice and opened under the ice to collect a water sample; the Lighweight Ice Auger, weighing only 32 pounds, can auger 6- and 8-inch holes through approximately 3.5 feet of ice; and the Ice Chisel has a specially hardened steel blade and 6-foot long, hickory D-handle.

  4. Predictions for surveys with the SPICA Mid-infrared Instrument

    CERN Document Server

    Bonato, M; Cai, Z -Y; De Zotti, G; Bressan, A; Wada, T; Kohno, K; Maiolino, R; Gruppioni, C; Pozzi, F; Lapi, A

    2015-01-01

    We present predictions for number counts and redshift distributions of galaxies detectable in continuum and in emission lines with the Mid-infrared (MIR) Instrument (SMI) proposed for the Space Infrared Telescope for Cosmology and Astrophysics (SPICA). We have considered 24 MIR fine-structure lines, four Polycyclic Aromatic Hydrocarbon (PAH) bands (at 6.2, 7.7, 8.6 and 11.3$\\mu$m) and two silicate bands (in emission and in absorption) at 9.7$\\mu$m and 18.0$\\mu$m. Six of these lines are primarily associated with Active Galactic Nuclei (AGNs), the others with star formation. A survey with the SMI spectrometers of 1 hour integration per field-of-view (FoV) over an area of $1\\,\\hbox{deg}^2$ will yield $5\\,\\sigma$ detections of $\\simeq 140$ AGN lines and of $\\simeq 5.2\\times10^{4}$ star-forming galaxies, $\\simeq 1.6\\times10^{4}$ of which will be detected in at least two lines. The combination of a shallow ($20.0\\,\\hbox{deg}^{2}$, $1.4\\times10^{-1}$ h integration per FoV) and a deep survey ($6.9\\times10^{-3}\\,\\hbox...

  5. Survey Instrument Validity Part II: Validation of a Survey Instrument Examining Athletic Trainers' Knowledge and Practice Beliefs Regarding Exertional Heat Stroke

    Science.gov (United States)

    Burton, Laura J.; Mazerolle, Stephanie M.

    2011-01-01

    Objective: The purpose of this article is to discuss the process of developing and validating an instrument to investigate an athletic trainer's attitudes and behaviors regarding the recognition and treatment of exertional heat stroke. Background: Following up from our initial paper, which discussed the process of survey instrument design and…

  6. Parents' childhood fever management: community survey and instrument development.

    Science.gov (United States)

    Walsh, Anne; Edwards, Helen; Fraser, Jenny

    2008-08-01

    This paper is a report of a study to explore Australian parents' knowledge, beliefs, practices and information sources about fever management and develop a scale to measure parents' fever management practices. Parental fever phobia and overuse of antipyretics to reduce fever continue. No scales to measure parents' fever management practices are available. A community-based, postal survey was carried out in 2005 with 401 Australian parents of well children aged 6 months-5 years. Respondents were recruited through advertising (48.4%), face-to-face (26.4%) and snowball (24.4%) methods. A 33-item instrument was developed; construct and content validity were determined by an expert panel and item reliability by test-retest. Moderate fever (40.0 +/- 1.0 degrees C) was reported to be harmful (88%), causing febrile convulsions (77.7%). Usual practices targeted temperature reduction, antipyretic administration (87.8%), temperature monitoring (52.5%). Fewer evidence-based practices, such as encouraging fluids (49.0%) and light clothing (43.8%), were reported. Positive changes over time (36.4%) included less concern and delayed or reduced antipyretic use. Negative practice changes (22.7%) included greater concern and increased antipyretic use. Medical advice was sought for illness symptoms (48.7%) and high (37.4%) or persistent (41.5%) fevers. Fever management was learnt from doctors, family and friends and working experience, while receiving conflicting information (41.9%) increased concerns and created uncertainty about best practice. Parents need consistent evidence-based information about childhood fever management. The Parental Fever Management Scale requires further testing with different populations and in different cultures and healthcare systems to evaluate its usefulness in nursing practice and research.

  7. Surveying Instruments: Their History and Classroom Use. National Council of Teachers of Mathematics, Yearbook 19 [1947].

    Science.gov (United States)

    Kiely, Edmond R.

    The first four chapters trace the history of surveying instruments from beginnings in Egypt, China, and Babylonia to Greece and Rome, then Europe, Islam, and India and finally in the Renaissance in Europe. The organization of these chapters is generally by the major areas of leveling instruments, right-angle instruments, staff combinations, and…

  8. Survey of instrumentation for environmental monitoring: major update. Volume 3. Radiation

    Energy Technology Data Exchange (ETDEWEB)

    1979-09-01

    This is the third volume of a four-volume (seven-part) series, the culmination of a comprehensive survey of instrumentation for environmental monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to radiation monitoring. The results of the survey are given as descriptions of the physical and operating characteristics of available instruments, critical comparisons among instrumentation methods, and recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored, their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls. The discussion is presented under sections entitled radiation sources; instrumentation: by type of radiation or instrument type; and, instrumentation for specific radionuclides. (JGB)

  9. Designing, Testing, and Validating an Attitudinal Survey on an Environmental Topic: A Groundwater Pollution Survey Instrument for Secondary School Students

    Science.gov (United States)

    Lacosta-Gabari, Idoya; Fernandez-Manzanal, Rosario; Sanchez-Gonzalez, Dolores

    2009-01-01

    Research in environmental attitudes' assessment has significantly increased in recent years. The development of specific attitude scales for specific environmental problems has often been proposed. This paper describes the Groundwater Pollution Test (GPT), a 19-item survey instrument using a Likert-type scale. The survey has been used with…

  10. Designing, Testing, and Validating an Attitudinal Survey on an Environmental Topic: A Groundwater Pollution Survey Instrument for Secondary School Students

    Science.gov (United States)

    Lacosta-Gabari, Idoya; Fernandez-Manzanal, Rosario; Sanchez-Gonzalez, Dolores

    2009-01-01

    Research in environmental attitudes' assessment has significantly increased in recent years. The development of specific attitude scales for specific environmental problems has often been proposed. This paper describes the Groundwater Pollution Test (GPT), a 19-item survey instrument using a Likert-type scale. The survey has been used with…

  11. Survey instruments used in clinical and epidemiological research on waterpipe tobacco smoking: a systematic review

    Directory of Open Access Journals (Sweden)

    Gunukula Sameer K

    2010-07-01

    Full Text Available Abstract Background The primary objective was to systematically review the medical literature for instruments validated for use in epidemiological and clinical research on waterpipe smoking. Methods We searched the following databases: MEDLINE, EMBASE, and ISI the Web of Science. We selected studies using a two-stage duplicate and independent screening process. We included papers reporting on the development and/or validation of survey instruments to measure waterpipe tobacco consumption or related concepts. Two reviewers used a standardized and pilot tested data abstraction form to collect data from each eligible study using a duplicate and independent screening process. We also determined the percentage of observational studies assessing the health effects of waterpipe tobacco smoking and the percentage of studies of prevalence of waterpipe tobacco smoking that have used validated survey instruments. Results We identified a total of five survey instruments. One instrument was designed to measure knowledge, attitudes, and waterpipe use among pregnant women and was shown to have internal consistency and content validity. Three instruments were designed to measure waterpipe tobacco consumption, two of which were reported to have face validity. The fifth instrument was designed to measure waterpipe dependence and was rigorously developed and validated. One of the studies of prevalence and none of the studies of health effects of waterpipe smoking used validated instruments. Conclusions A number of instruments for measuring the use of and dependence on waterpipe smoking exist. Future research should study content validity and cross cultural adaptation of these instruments.

  12. BUSINESS SURVEYS-EVALUATION INSTRUMENT OF THE EUROPEAN ECONOMIC CLIMATE

    Directory of Open Access Journals (Sweden)

    SECAREANU CONSTANTIN

    2010-07-01

    Full Text Available Business surveys or conjuncture surveys are specific statiostical researches, but complementary to traditional, official statistics.While official statistics provide quantitive information regardin the level,structure and evolution of varied economic process and phenomena, business surveys offer quality information, essential to the short term evolutional analysis of economic indicators: the diagnosis of the current situation, the timely detection of inflexion points within the economic cycle and the rapid estimation of short term tendencies of the main macroeconomic indicators (the dynamics of the gross domestic product, the index of industrial production, etc.

  13. Measuring Quality of Life: A New and Practical Survey Instrument.

    Science.gov (United States)

    Greenley, James R.; Greenberg, Jan Steven; Brown, Roger

    1997-01-01

    Presents a new, short, self-administered questionnaire that assesses the quality of life in seven areas. Evidence for the reliability and validity of the questionnaire was based on data gathered from 971 clients; results indicate instrument reliability. The questionnaire features low-cost administration and valid psychometric properties. (RJM)

  14. Language Awareness Surveys: A Rationale and Three Instruments.

    Science.gov (United States)

    Belanger, Joe

    Noting that language study (one leg of the traditional English tripod of language, literature, and composition) has received mixed attention internationally and is almost forgotten in North America, this paper presents a rationale for researching language awareness and three instruments that can be used in such research. The paper begins with…

  15. The SAMI Galaxy Survey: instrument specification and target selection

    CERN Document Server

    Bryant, J J; Robotham, A S G; Croom, S M; Driver, S P; Drinkwater, M J; Lorente, N P F; Cortese, L; Scott, N; Colless, M; Schaefer, A; Taylor, E N; Konstantopoulos, I S; Allen, J T; Baldry, I; Barnes, L; Bauer, A E; Bland-Hawthorn, J; Bloom, J V; Brooks, A M; Brough, S; Cecil, G; Couch, W; Croton, D; Davies, R; Ellis, S; Fogarty, L M R; Foster, C; Glazebrook, K; Goodwin, M; Green, A; Gunawardhana, M L; Hampton, E; Ho, I -T; Hopkins, A M; Kewley, L; Lawrence, J S; Leon-Saval, S G; Leslie, S; Lewis, G; Liske, J; Lopez-Sanchez, A R; Mahajan, S; Medling, A M; Metcalfe, N; Meyer, M; Mould, J; Obreschkow, D; O'Toole, S; Pracy, M; Richards, S N; Shanks, T; Sharp, R; Sweet, S M; Thomas, A D; Tonini, C; Walcher, C J

    2014-01-01

    The SAMI Galaxy Survey will observe 3400 galaxies with the Sydney-AAO Multi-object Integral-field spectrograph (SAMI) on the Anglo-Australian Telescope (AAT) in a 3-year survey which began in 2013. We present the throughput of the SAMI system, the science basis and specifications for the target selection, the survey observation plan and the combined properties of the selected galaxies. The survey includes four volume limited galaxy samples based on cuts in a proxy for stellar mass, along with low-stellar mass dwarf galaxies all selected from the Galaxy And Mass Assembly (GAMA) survey. The GAMA regions were selected because of the vast array of ancillary data available, including ultraviolet through to radio bands. These fields are on the celestial equator at 9, 12, and 14.5 hours, and cover a total of 144 square degrees (in GAMA-I). Higher density environments are also included with the addition of eight clusters. The clusters have spectroscopy from 2dFGRS and SDSS and photometry in regions covered by the Slo...

  16. Site survey instrumentation for the National New Technology Telescope (NNTT)

    Science.gov (United States)

    Forbes, F. F.; Morse, D. A.; Poczulp, G. A.

    1988-10-01

    The characterization of atmospheric turbulence at and above the two candidate sites for the 15 m National New Technology Telescope (NNTT) has required the development of specialized measurement techniques. The equipment used to measure astronomical seeing, microthermals, water vapor, and temperature is discussed, along with sample data and calibration results. By use of instruments with overlapping altitude coverage, it has been possible to 'bookkeep' qualitatively all of the sources of innate degradation, especially near the ground.

  17. School Leadership Preparation and Practice Survey Instruments and Their Uses

    Science.gov (United States)

    Pounder, Diana

    2012-01-01

    This article addresses the leadership preparation line of inquiry developed in the past decade by the University Council for Educational Administration/Learning and Teaching in Educational Leadership Special Interest Group Taskforce on Evaluating Leadership Preparation Programs, and it particularly addresses the series of survey instruments…

  18. Survey of instrumentation used for monitoring metals in water

    Energy Technology Data Exchange (ETDEWEB)

    Quinby-Hunt, M.S.

    1978-06-01

    A study was conducted of instrumentation used to determine metals in water. Several of the techniques most commonly used for analysis and routine determinations of metals in water are shown in Table 1. They are atomic absorption spectroscopy, both flame and flameless, atomic emission spectroscopy using conventional flame sources and inductively-coupled plasma sources, and ultraviolet-visible absorption techniques. Other less frequently employed methods are x-ray fluorescence analysis using both photon and charged particle excitation with energy-dispersive and wavelength-dispersive spectral analysis. Also electrochemical techniques and activation analysis are studied.

  19. The New Mexico Tech Extrasolar Spectroscopic Survey Instrument (NESSI)

    Science.gov (United States)

    Creech-Eakman, Michelle J.; Jurgenson, C.; Vasisht, G.; Swain, M.; Boston, P.; Santoro, F.

    2010-01-01

    We present the design and scientific objectives behind NESSI, a near-infrared spectroscopic purpose-built for studying exoplanet atmospheres. This instrument is being designed and assembled by a team of scientists and engineers at New Mexico Tech (NMT), the Magdalena Ridge Observatory (MRO) and NASA's Jet Propulsion Lab (JPL), and is scheduled for deployment in late 2010 at the MRO 2.4m telescope. NESSI's unique design is driven by recent space and ground-based NIR spectroscopy of exoplanet atmospheres by members of our team. Optimization of the instrument to achieve 0.01% relative accuracies in spectra of exoplanetary molecular constituents requires careful attention to certain design features and a new technical approach. We present an overview of NESSI's design, including the four major subassemblies: 1) a field derotator, 2) a reimaging module, 3) an optical guiding module, and 4) a multi-object spectrograph subassembly. We also present an overview of our science program specifically designed to build the community of exoplanet researchers and students in NM. The financial support of our team and NESSI itself have been made possible by a NM NASA EPSCoR grant, matching funds from the NMT administration, and internal support for the NESSI hardware from Dr. Van Romero, NMT's Research Vice-President.

  20. The Multi-sensor Airborne Radiation Survey (MARS) Instrument

    Energy Technology Data Exchange (ETDEWEB)

    Fast, James E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Aalseth, Craig E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Asner, David M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bonebrake, Christopher A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Day, Anthony R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Dorow, Kevin E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fuller, Erin S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Glasgow, Brian D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hossbach, Todd W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hyronimus, Brian J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jensen, Jeffrey L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Johnson, Kenneth I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jordan, David V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Morgen, Gerald P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Morris, Scott J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mullen, O Dennis [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Myers, Allan W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Pitts, W. Karl [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rohrer, John S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Runkle, Robert C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Seifert, Allen [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Shergur, Jason M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Stave, Sean C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tatishvili, Gocha [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Thompson, Robert C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Todd, Lindsay C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Warren, Glen A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Willett, Jesse A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wood, Lynn S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2013-01-11

    The Multi-sensor Airborne Radiation Survey (MARS) project has developed a new single cryostat detector array design for high purity germanium (HPGe) gama ray spectrometers that achieves the high detection efficiency required for stand-off detection and actionable characterization of radiological threats. This approach, we found, is necessary since a high efficiency HPGe detector can only be built as an array due to limitations in growing large germanium crystals. Moreover, the system is ruggedized and shock mounted for use in a variety of field applications, including airborne and maritime operations.

  1. Two valuation questions in one survey: Is it a recipe for sequencing and instrument context effects?

    Science.gov (United States)

    Giraud, K.L.; Loomis, J.B.; Johnson, R.L.

    1999-01-01

    Economic theory suggests that willingness to pay for two goods independently offered should remain unchanged when the survey instrument changes slightly. Four survey treatments consisting of comprehensive good and a subset of that good were used. The surveys alternated in the question ordering and in the embedded good which accompanied the comprehensive good. We tested for sequencing and instrument context effects using both a combined and split sample designs. In the combined sample case we found some evidence to sequencing effects in the data containing the first subset good. Likelihood ratio tests indicated that sequencing did not effect scale or location of parameters. In the test for instrument context effects, evidence was found indicating context does effect willingness to pay estimates.

  2. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2001-04-01

    SCK-CEN's research and development programme on instrumentation involves the assessment and the development of sensitive measurement systems used within a radiation environment. Particular emphasis is on the assessment of optical fibre components and their adaptability to radiation environments. The evaluation of ageing processes of instrumentation in fission plants, the development of specific data evaluation strategies to compensate for ageing induced degradation of sensors and cable performance form part of these activities. In 2000, particular emphasis was on in-core reactor instrumentation applied to fusion, accelerator driven and water-cooled fission reactors. This involved the development of high performance instrumentation for irradiation experiments in the BR2 reactor in support of new instrumentation needs for MYRRHA, and for diagnostic systems for the ITER reactor.

  3. Using Moodle as On-line Survey Instrument in Medical Education

    Directory of Open Access Journals (Sweden)

    Dan ISTRATE

    2013-02-01

    Full Text Available One of the principal issues in any university community is the lack of communication between community categories – leadership, administration, teaching staff and students. Sometimes is important to know in a short time the opinion of one particular group, without investing a lot of resources and without being extremely formal. The aim of this study was to test if an open-source platform – Moodle – can be used for quick surveys inside the Faculty of Medicine, UMF “Iuliu Hatieganu” Cluj-Napoca community. For this, on existing Moodle platform was installed one specific survey instrument – a questionnaire module and a survey containing a real life issue to the students of Faculty of Medicine was launched. The researchers have focused on how the specific problems of a survey - preparing of the survey, the survey process and the analysis of the results can be handle in Moodle. The pilot survey was a success; the conclusion of the study was that Moodle can be used as on-line survey instrument for that community.

  4. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2002-04-01

    SCK-CEN's R and D programme on instrumentation involves the development of advanced instrumentation systems for nuclear applications as well as the assessment of the performance of these instruments in a radiation environment. Particular emphasis is on the use of optical fibres as umbilincal links of a remote handling unit for use during maintanance of a fusion reacor, studies on the radiation hardening of plasma diagnostic systems; investigations on new instrumentation for the future MYRRHA accelerator driven system; space applications related to radiation-hardened lenses; the development of new approaches for dose, temperature and strain measurements; the assessment of radiation-hardened sensors and motors for remote handling tasks and studies of dose measurement systems including the use of optical fibres. Progress and achievements in these areas for 2001 are described.

  5. Instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    2000-07-01

    SCK-CEN's research and development programme on instrumentation aims at evaluating the potentials of new instrumentation technologies under the severe constraints of a nuclear application. It focuses on the tolerance of sensors to high radiation doses, including optical fibre sensors, and on the related intelligent data processing needed to cope with the nuclear constraints. Main achievements in these domains in 1999 are summarised.

  6. Development and validation of a survey instrument to measure children's advertising literacy

    NARCIS (Netherlands)

    Rozendaal, E.; Opree, S.J.; Buijzen, M.A.

    2016-01-01

    The aim of this study was to develop and validate a survey measurement instrument for children's advertising literacy. Based on the multidimensional conceptualization of advertising literacy by 0056"> Rozendaal, Lapierre, Van Reijmersdal, and Buijzen (2011), 39 items were created to measure two d

  7. Establishing Educational Priorities through the Illinois Problems Index. Survey Instruments [and] User's Manual.

    Science.gov (United States)

    Illinois State Board of Education, Springfield.

    The Illinois Problems Index (IPI), a process with supporting survey instruments, enables local school districts to assess and evaluate the adequacy of current programs and services and plan improvements where problems exist. A User's Manual provides a step-by-step "walk through" of the process, while permitting alternative techniques for…

  8. Development and validation of a survey instrument to measure children's advertising literacy

    NARCIS (Netherlands)

    Rozendaal, E.; Opree, S.J.; Buijzen, M.A.

    2016-01-01

    The aim of this study was to develop and validate a survey measurement instrument for children's advertising literacy. Based on the multidimensional conceptualization of advertising literacy by 0056"> Rozendaal, Lapierre, Van Reijmersdal, and Buijzen (2011), 39 items were created to measure two

  9. Comparing NICU teamwork and safety climate across two commonly used survey instruments.

    Science.gov (United States)

    Profit, Jochen; Lee, Henry C; Sharek, Paul J; Kan, Peggy; Nisbet, Courtney C; Thomas, Eric J; Etchegaray, Jason M; Sexton, Bryan

    2016-12-01

    Measurement and our understanding of safety culture are still evolving. The objectives of this study were to assess variation in safety and teamwork climate and in the neonatal intensive care unit (NICU) setting, and compare measurement of safety culture scales using two different instruments (Safety Attitudes Questionnaire (SAQ) and Hospital Survey on Patient Safety Culture (HSOPSC)). Cross-sectional survey study of a voluntary sample of 2073 (response rate 62.9%) health professionals in 44 NICUs. To compare survey instruments, we used Spearman's rank correlation coefficients. We also compared similar scales and items across the instruments using t tests and changes in quartile-level performance. We found significant variation across NICUs in safety and teamwork climate scales of SAQ and HSOPSC (pteamwork scales (teamwork climate and teamwork within units) of the two instruments correlated strongly (safety r=0.72, pteamwork r=0.67, p<0.001). However, the means and per cent agreements for all scale scores and even seemingly similar item scores were significantly different. In addition, comparisons of scale score quartiles between the two instruments revealed that half of the NICUs fell into different quartiles when translating between the instruments. Large variation and opportunities for improvement in patient safety culture exist across NICUs. Important systematic differences exist between SAQ and HSOPSC such that these instruments should not be used interchangeably. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  10. Instruments

    Energy Technology Data Exchange (ETDEWEB)

    Buehrer, W. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1996-12-31

    The present paper mediates a basic knowledge of the most commonly used experimental techniques. We discuss the principles and concepts necessary to understand what one is doing if one performs an experiment on a certain instrument. (author) 29 figs., 1 tab., refs.

  11. Understanding Teachers' Conceptions of Classroom Inquiry With a Teaching Scenario Survey Instrument

    Science.gov (United States)

    Kang, Nam-Hwa; Orgill, Marykay; Crippen, Kent J.

    2008-08-01

    A survey instrument using everyday teaching scenarios was developed to measure teacher conceptions of inquiry. Validity of the instrument was established by comparing responses for a group of secondary teachers to narrative writing and group discussion. Participating teachers used only three of the five essential features of inquiry detailed in the standards documents (NRC 2000) when expressing their ideas of classroom inquiry. The features of ‘evaluating explanations in connection with scientific knowledge’ and ‘communicating explanations’ were rarely mentioned. These missing components indicate a gap between the teachers’ conceptions of inquiry and the ideals of the reform movement.

  12. Evaluation of a Brief Survey Instrument for Assessing Subtle Differences in Cognitive Function Among Older Adults.

    Science.gov (United States)

    Kotwal, Ashwin A; Schumm, Philip; Kern, David W; McClintock, Martha K; Waite, Linda J; Shega, Joseph W; Huisingh-Scheetz, Megan J; Dale, William

    2015-01-01

    Most measures of cognitive function used in large-scale surveys of older adults have limited ability to detect subtle differences across cognitive domains, and standard clinical instruments are impractical to administer in general surveys. The Montreal Cognitive Assessment (MoCA) can address this need, but has limitations in a survey context. Therefore, we developed a survey adaptation of the MoCA, called the MoCA-SA, and describe its psychometric properties in a large national survey. Using a pretest sample of older adults (n=120), we reduced MoCA administration time by 26%, developed a model to accurately estimate full MoCA scores from the MoCA-SA, and tested the model in an independent clinical sample (n=93). The validated 18-item MoCA-SA was then administered to community-dwelling adults aged 62 to 91 as part of the National Social life Health and Aging Project Wave 2 sample (n=3196). In National Social life Health and Aging Project Wave 2, the MoCA-SA had good internal reliability (Cronbach α=0.76). Using item-response models, survey-adapted items captured a broad range of cognitive abilities and functioned similarly across sex, education, and ethnic groups. Results demonstrate that the MoCA-SA can be administered reliably in a survey setting while preserving sensitivity to a broad range of cognitive abilities and similar performance across demographic subgroups.

  13. Advanced Camera for Surveys Instrument Handbook for Cycle 25 v. 16.0

    Science.gov (United States)

    Avila, R. J.

    2017-01-01

    The Advanced Camera for Surveys (ACS), a third-generation instrument, was installed in the Hubble Space Telescope during Servicing Mission 3B, on March 7, 2002. Its primary purpose was to increase HST imaging discovery efficiency by about a factor of 10, with a combination of detector area and quantum efficiency that surpasses previous instruments. ACS has three independent cameras that have provided wide-field, high resolution, and ultraviolet imaging capabilities respectively, using a broad assortment of filters designed to address a large range of scientific goals. In addition, coronagraphic, polarimetric, and grism capabilities have made the ACS a versatile and powerful instrument. The ACS Instrument Handbook, which is maintained by the ACS Team at STScI, descr ibes the instrument properties, performance, operations, and calibration. It is the basic technical reference manual for the instrument, and should be used with other documents (listed in Table 1.1) for writing Phase I proposals, detailed Phase II programs, and for data analysis. (See Figure 1.1). In May 2009, Servicing Mission 4 (SM4) successfully restored the ACS Wide Field Camera (WFC) to regular service after its failure in January 2007. Unfortunately, the ACS High Resolution Camera (HRC) was not restored to operation during SM4, so it cannot be proposed for new observations. Nevertheless, this handbook retains description of the HRC to support analysis of archived observations. The ACS Solar Blind Channel (SBC) was unaffected by the January 2007 failure of WFC and HRC. The SBC has remained in steady operation, and was not serviced during SM4. It remains available for new observations.

  14. The Dark Energy Spectroscopic Instrument (DESI): Science from the DESI Survey

    Science.gov (United States)

    Eisenstein, Daniel; DESI Collaboration

    2015-01-01

    The Dark Energy Spectroscopic Instrument (DESI) will enable an ambitious redshift survey to probe dark energy by the baryon acoustic oscillation and redshift-space distortion methods. The same data set will serve numerous other goals in cosmology and astrophysics. Using a new 5000-fiber instrument and 8 square degree field of view at the Mayall telescope, the DESI survey plans to cover 14,000 square degrees and about 25 million high-redshift objects. The targets include 4M luminous red galaxies (redshift 0.4-1.0), 18M emission line galaxies (redshift 0.6-1.6), and 2.4M quasars, including 0.7M Lyman-alpha forest sight lines. With this, DESI can map the expansion history of the Universe to redshift 3, achieving unprecedented performance from the baryon acoustic oscillation method. We will describe the present state of the survey design and the cosmological forecasts for dark energy, inflation, and neutrino physics. We also give an update on the DESI Science Collaboration.

  15. The Application of Surveying Biochemistry Light Instrument in the Reaction System of Starch with Mn3+

    Institute of Scientific and Technical Information of China (English)

    Gu Zhengbiao; Wu Jiagen

    2000-01-01

    The possibility of the application of Surveying Biochemistry Light Instrument (SBLI) in the reaction system of starch with Mn3+was studied. The results showed: neither starch nor initiator(Mn3+) could produce light because no factor that could produce light existed in them. But starch could produce light when it was acted by Mn3 + and the intensity of light depended on the kind and concentration of starch, the amount of Mn3 +, the temperature and pH of the reaction system. In addition, the intensity of light decreased with the reaction time because of the gradual disappearance of starch free radicals.

  16. Creation and Use of a Survey Instrument for Comparing Mobile Computing Devices

    Science.gov (United States)

    Macri, Jennifer M.; Lee, Paul P.; Silvey, Garry M.; Lobach, David F.

    2005-01-01

    Both personal digital assistants (PDAs) and tablet computers have emerged to facilitate data collection at the point of care. However, little research has been reported comparing these mobile computing devices in specific care settings. In this study we present an approach for comparing functionally identical applications on a Palm operating system-based PDA and a Windows-based tablet computer for point-of-care documentation of clinical observations by eye care professionals when caring for patients with diabetes. Eye-care professionals compared the devices through focus group sessions and through validated usability surveys. This poster describes the development and use of the survey instrument used for comparing mobile computing devices. PMID:16779327

  17. Assessing or Reaffirming Accreditation Criteria for the Southern Association of Colleges and Schools (SACS): Development of an Alumni Survey Instrument.

    Science.gov (United States)

    Johnson, William L.; Johnson, Annabel M.

    The "Criteria for Accreditation" (1991) and reaffirmation published by the Southern Association of Colleges and Schools were validated through a survey of alumni. The criteria were developed to assist institutions in evaluating their effectiveness. In all, 2,300 survey instruments were mailed to college alumni in the United States. Of…

  18. Predicting Student Performance in Web-Based Distance Education Courses Based on Survey Instruments Measuring Personality Traits and Technical Skills

    Science.gov (United States)

    Hall, Michael

    2008-01-01

    Two common web-based surveys, "Is Online Learning Right for Me?' and "What Technical Skills Do I Need?", were combined into a single survey instrument and given to 228 on-campus and 83 distance education students. The students were enrolled in four different classes (business, computer information services, criminal justice, and…

  19. Psychometric properties of the Dutch version of the hospital-level consumer assessment of health plans survey (R) instrument

    NARCIS (Netherlands)

    O.A. Arah; A.H.A. ten Asbroek; D.M.J. Delnoij; J.S. de Koning; P.J.A. Stam; A.H. Poll; B. Vriens; P.F. Schmidt; N.S. Klazinga

    2006-01-01

    Objectives. To assess the reliability and validity of a translated version of the American Hospital-level Consumer Assessment of Health Plans Survey (R) (H-CAHPS) instrument for use in Dutch health care. Data Sources/Study Setting. Primary survey data from adults aged 18 years or more who were recen

  20. BALLISTIC RESISTANT ARTICLES COMPRISING TAPES

    NARCIS (Netherlands)

    VAN DER EEM, JORIS; HARINGS, JULES; JANSE, GERARDUS; TJADEN, HENDRIK

    2015-01-01

    The invention pertains to a ballistic-resistant moulded article comprising a compressed stack of sheets comprising reinforcing tapes having a tensile strength of at least 1.0 GPa, a tensile modulus of at least 40 GPa, and a tensile energy-to-break of at least 15 J/g, the direction of the tapes withi

  1. BALLISTIC RESISTANT ARTICLES COMPRISING TAPES

    NARCIS (Netherlands)

    VAN DER EEM, JORIS; HARINGS, JULES; JANSE, GERARDUS; TJADEN, HENDRIK

    2015-01-01

    The invention pertains to a ballistic-resistant moulded article comprising a compressed stack of sheets comprising reinforcing tapes having a tensile strength of at least 1.0 GPa, a tensile modulus of at least 40 GPa, and a tensile energy-to-break of at least 15 J/g, the direction of the tapes

  2. Measuring determinants of career satisfaction of anesthesiologists: validation of a survey instrument.

    Science.gov (United States)

    Afonso, Anoushka M; Diaz, James H; Scher, Corey S; Beyl, Robbie A; Nair, Singh R; Kaye, Alan David

    2013-06-01

    To measure the parameter of job satisfaction among anesthesiologists. Survey instrument. Academic anesthesiology departments in the United States. 320 anesthesiologists who attended the annual meeting of the ASA in 2009 (95% response rate). The anonymous 50-item survey collected information on 26 independent demographic variables and 24 dependent ranked variables of career satisfaction among practicing anesthesiologists. Mean survey scores were calculated for each demographic variable and tested for statistically significant differences by analysis of variance. Questions within each domain that were internally consistent with each other within domains were identified by Cronbach's alpha ≥ 0.7. P-values ≤ 0.05 were considered statistically significant. Cronbach's alpha analysis showed strong internal consistency for 10 dependent outcome questions in the practice factor-related domain (α = 0.72), 6 dependent outcome questions in the peer factor-related domain (α = 0.71), and 8 dependent outcome questions in the personal factor-related domain (α = 0.81). Although age was not a variable, full-time status, early satisfaction within the first 5 years of practice, working with respected peers, and personal choice factors were all significantly associated with anesthesiologist job satisfaction. Improvements in factors related to job satisfaction among anesthesiologists may lead to higher early and current career satisfaction. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Survey Instruments for Knowledge, Skills, Attitudes and Behaviour Related to Evidence-based Practice in Occupational Therapy: A Systematic Review.

    Science.gov (United States)

    Buchanan, Helen; Siegfried, Nandi; Jelsma, Jennifer

    2016-06-01

    The purpose of this study was to evaluate, through a systematic review, assessment instruments for evidence-based practice (EBP). The specific objectives were to (1) identify survey instruments testing EBP knowledge, skills, attitudes and behaviour; (2) determine the attributes measured by each instrument; (3) evaluate the psychometric properties of the instruments; and (4) evaluate the methodological quality of the instruments. Using the Cochrane approach, searches were conducted in Pubmed, EBSCOHost and Scopus from inception to February 2014. Papers were screened by two independent assessors, and data were extracted by one researcher. Forty papers reporting 34 instruments met the inclusion criteria and were included in the qualitative synthesis. Most instruments measured EBP behaviour (n = 33) and attitudes (n = 21). This review provides a single source of information to enable researchers to select the most robust descriptive instruments to measure EBP learner attributes. Instruments used only with occupational therapists may have resulted in some instruments being missed. For further research, it is recommended that attention is given to developing objective instruments with a focus on knowledge and skills. Copyright © 2015 John Wiley & Sons, Ltd.

  4. Development and validation of a survey instrument for assessing prescribers' perception of computerized drug-drug interaction alerts.

    Science.gov (United States)

    Zheng, Kai; Fear, Kathleen; Chaffee, Bruce W; Zimmerman, Christopher R; Karls, Edward M; Gatwood, Justin D; Stevenson, James G; Pearlman, Mark D

    2011-12-01

    To develop a theoretically informed and empirically validated survey instrument for assessing prescribers' perception of computerized drug-drug interaction (DDI) alerts. The survey is grounded in the unified theory of acceptance and use of technology and an adapted accident causation model. Development of the instrument was also informed by a review of the extant literature on prescribers' attitude toward computerized medication safety alerts and common prescriber-provided reasons for overriding. To refine and validate the survey, we conducted a two-stage empirical validation study consisting of a pretest with a panel of domain experts followed by a field test among all eligible prescribers at our institution. The resulting survey instrument contains 28 questionnaire items assessing six theoretical dimensions: performance expectancy, effort expectancy, social influence, facilitating conditions, perceived fatigue, and perceived use behavior. Satisfactory results were obtained from the field validation; however, a few potential issues were also identified. We analyzed these issues accordingly and the results led to the final survey instrument as well as usage recommendations. High override rates of computerized medication safety alerts have been a prevalent problem. They are usually caused by, or manifested in, issues of poor end user acceptance. However, standardized research tools for assessing and understanding end users' perception are currently lacking, which inhibits knowledge accumulation and consequently forgoes improvement opportunities. The survey instrument presented in this paper may help fill this methodological gap. We developed and empirically validated a survey instrument that may be useful for future research on DDI alerts and other types of computerized medication safety alerts more generally.

  5. Measuring social exclusion in routine public health surveys: construction of a multidimensional instrument.

    Directory of Open Access Journals (Sweden)

    Addi P L van Bergen

    Full Text Available INTRODUCTION: Social exclusion is considered a major factor in the causation and maintenance of health inequalities, but its measurement in health research is still in its infancy. In the Netherlands the Institute for Social Research (SCP developed an instrument to measure the multidimensional concept of social exclusion in social and economic policy research. Here, we present a method to construct a similar measure of social exclusion using available data from public health surveys. METHODS: Analyses were performed on data from the health questionnaires that were completed by 20,877 adults in the four largest cities in the Netherlands. From each of the four questionnaires we selected the items that corresponded to those of the SCP-instrument. These were entered into a nonlinear canonical correlation analysis. The measurement properties of the resulting indices and dimension scales were assessed and compared to the SCP-instrument. RESULTS: The internal consistency of the indices and most of the dimension scales were adequate and the internal structure of the indices was as expected. Both generalisabiliy and construct validity were good: in all datasets strong associations were found between the index and a number of known risk factors of social exclusion. A limitation of content validity was that the dimension "lack of normative integration" could not be measured, because no relevant items were available. CONCLUSIONS: Our findings indicate that a measure for social exclusion can be constructed with available health questionnaires. This provides opportunities for application in public health surveillance systems in the Netherlands and elsewhere in the world.

  6. The Gaia spectrophotometric standard stars survey -II. Instrumental effects of six ground-based observing campaigns

    CERN Document Server

    Altavilla, G; Pancino, E; Galleti, S; Ragaini, S; Bellazzini, M; Cocozza, G; Bragaglia, A; Carrasco, J M; Castro, A; Di Fabrizio, L; Federici, L; Figueras, F; Gebran, M; Jordi, C; Masana, E; Schuster, W; Valentini, G; Voss, H

    2015-01-01

    The Gaia SpectroPhotometric Standard Stars (SPSS) survey started in 2006, it was awarded almost 450 observing nights, and accumulated almost 100,000 raw data frames, with both photometric and spectroscopic observations. Such large observational effort requires careful, homogeneous, and automated data reduction and quality control procedures. In this paper, we quantitatively evaluate instrumental effects that might have a significant (i.e.,$\\geq$1%) impact on the Gaia SPSS flux calibration. The measurements involve six different instruments, monitored over the eight years of observations dedicated to the Gaia flux standards campaigns: DOLORES@TNG in La Palma, EFOSC2@NTT and ROSS@REM in La Silla, CAFOS@2.2m in Calar Alto, BFOSC@Cassini in Loiano, and LaRuca@1.5m in San Pedro Martir. We examine and quantitatively evaluate the following effects: CCD linearity and shutter times, calibration frames stability, lamp flexures, second order contamination, light polarization, and fringing. We present methods to correct ...

  7. Dental Management Survey Brazil (DMS-BR): creation and validation of a management instrument

    Science.gov (United States)

    Gonzales, Paola Sampaio; Martins, Ismar Eduardo; Biazevic, Maria Gabriela Haye; Silva, Paulo Roberto da; Michel-Crosato, Edgard

    2017-04-10

    Questionnaires for the assessment of knowledge and self-perception can be useful to diagnose what a dentist knows about management and administration. The aim of the present study was to create and validate the Dental Management Survey Brazil (DMS-BR) scale, based on meetings with experts in the field. After having elaborated the first version, 10 audits were performed in dental offices in order to produce the final version, which included nine dimensions: location, patient, finance, marketing, competition, quality, staff, career, and productivity. The accuracy of the instrument was measured by intrarater and interrater reliability. In the validation phase, 247 Brazilian dentists answered a web-based questionnaire. The data were processed using Stata 13.0 and the significance level was set at 95%. The instrument had intrarater and interrater reliability (ICC-0.93 and 0.94). The overall average of respondents for the DMS-BR scale was 3.77 (SD = 0.45). Skewness and kurtosis were below absolute values 3 and 7, respectively. Internal validity measured by Cronbach's alpha was 0.925 and the correlation of each dimension with the final result of the DMS-BR ranged between 0.606 and 0.810. Correlation with the job satisfaction scale was 0.661. The SEM data ranged between 0.80 and 0.56. The questionnaire presented satisfactory indicators of dentists' self-perception about management and administration activities.

  8. Mechanical Design of NESSI: New Mexico Tech Extrasolar Spectroscopic Survey Instrument

    Science.gov (United States)

    Santoro, Fernando G.; Olivares, Andres M.; Salcido, Christopher D.; Jimenez, Stephen R.; Jurgenson, Colby A.; Hrynevych, Michael A.; Creech-Eakman, Michelle J.; Boston, Penny J.; Schmidt, Luke M.; Bloemhard, Heather; Rodeheffer, Dan; Vaive, Genevieve; Vasisht, Gautam; Swain, Mark R.; Deroo, Pieter

    2011-01-01

    NESSI: the New Mexico Tech Extrasolar Spectroscopic Survey Instrument is a ground-based multi-object spectrograph that operates in the near-infrared. It will be installed on one of the Nasmyth ports of the Magdalena Ridge Observatory (MRO) 2.4-meter Telescope sited in the Magdalena Mountains, about 48 km west of Socorro-NM. NESSI operates stationary to the telescope fork so as not to produce differential flexure between internal opto-mechanical components during or between observations. An appropriate mechanical design allows the instrument alignment to be highly repeatable and stable for both short and long observation timescales, within a wide-range of temperature variation. NESSI is optically composed of a field lens, a field de-rotator, re-imaging optics, an auto-guider and a Dewar spectrograph that operates at LN2 temperature. In this paper we report on NESSI's detailed mechanical and opto-mechanical design, and the planning for mechanical construction, assembly, integration and verification.

  9. A frailty instrument for primary care: findings from the Survey of Health, Ageing and Retirement in Europe (SHARE).

    LENUS (Irish Health Repository)

    Romero-Ortuno, Roman

    2010-01-01

    A frailty paradigm would be useful in primary care to identify older people at risk, but appropriate metrics at that level are lacking. We created and validated a simple instrument for frailty screening in Europeans aged ≥50. Our study is based on the first wave of the Survey of Health, Ageing and Retirement in Europe (SHARE, http:\\/\\/www.share-project.org), a large population-based survey conducted in 2004-2005 in twelve European countries.

  10. Economic instruments for obesity prevention: results of a scoping review and modified delphi survey

    Directory of Open Access Journals (Sweden)

    LaFrance Jeffrey

    2011-10-01

    Full Text Available Abstract Background Comprehensive, multi-level approaches are required to address obesity. One important target for intervention is the economic domain. The purpose of this study was to synthesize existing evidence regarding the impact of economic policies targeting obesity and its causal behaviours (diet, physical activity, and to make specific recommendations for the Canadian context. Methods Arksey and O'Malley's (2005 methodological framework for conducting scoping reviews was adopted for this study and this consisted of two phases: 1 a structured literature search and review, and 2 consultation with experts in the research field through a Delphi survey and an in-person expert panel meeting in April 2010. Results Two key findings from the scoping review included 1 consistent evidence that weight outcomes are responsive to food and beverage prices. The debate on the use of food taxes and subsidies to address obesity should now shift to how best to address practical issues in designing such policies; and 2 very few studies have examined the impact of economic instruments to promote physical activity and clear policy recommendations cannot be made at this time. Delphi survey findings emphasised the relatively modest impact any specific economic instrument would have on obesity independently. Based on empirical evidence and expert opinion, three recommendations were supported. First, to create and implement an effective health filter to review new and current agricultural polices to reduce the possibility that such policies have a deleterious impact on population rates of obesity. Second, to implement a caloric sweetened beverage tax. Third, to examine how to implement fruit and vegetable subsidies targeted at children and low income households. Conclusions In terms of economic interventions, shifting from empirical evidence to policy recommendation remains challenging. Overall, the evidence is not sufficiently strong to provide clear policy

  11. Ergonomics and design of laparoscopic instruments: results of a survey among laparoscopic surgeons.

    Science.gov (United States)

    Van Veelen, M A; Meijer, D W

    1999-12-01

    This study determined which types of laparoscopic instruments are most often used in Europe, why they are being used, and what problems exist while using the instruments. The handles were also evaluated according to ergonomic design criteria. A questionnaire was send to 62 experienced surgeons in 19 countries. The laparoscopic instruments were divided into four groups: instruments with similar functionality and handgrip model were grouped together. Eight questions were asked for every group about the type of instrument (disposable, reusable, or semireusable), the type of handle, the reason for using a specific instrument, and the experience of discomfort while using the instrument. The handles of the instruments of the group that were associated with the greatest discomfort were ergonomically evaluated on eight aspects (dimensions, angles, and control). Half of the questionnaires were returned. In every group, about 80% of the instruments the surgeons employed were reusable. The chief reason for using a specific type was the good cost-quality of the product and satisfying experiences with other products of the brand. The discomfort was pressure on thumb and fingers (scissors handle) and fixating the tip (ratchet). The handle of the instruments that causes the most discomfort met only three of the eight ergonomic requirements. Most of the laparoscopic instruments employed by surgeons in Europe are reusable. A significant number of the instruments cause discomfort. These instruments do not meet standard ergonomic requirements.

  12. Articles comprising ferritic stainless steels

    Energy Technology Data Exchange (ETDEWEB)

    Rakowski, James M.

    2016-06-28

    An article of manufacture comprises a ferritic stainless steel that includes a near-surface region depleted of silicon relative to a remainder of the ferritic stainless steel. The article has a reduced tendency to form an electrically resistive silica layer including silicon derived from the steel when the article is subjected to high temperature oxidizing conditions. The ferritic stainless steel is selected from the group comprising AISI Type 430 stainless steel, AISI Type 439 stainless steel, AISI Type 441 stainless steel, AISI Type 444 stainless steel, and E-BRITE.RTM. alloy, also known as UNS 44627 stainless steel. In certain embodiments, the article of manufacture is a fuel cell interconnect for a solid oxide fuel cell.

  13. Avionics Instrument Systems Specialist Career Ladder: AFSCs 32531, 32551, 31571, and 32591. Occupational Survey Report.

    Science.gov (United States)

    Air Force Occupational Measurement Center, Lackland AFB, TX.

    The Avionics Instrument Systems career ladder (AFSC 325X1) provides flight line and shop maintenance training on aircraft instrument systems, electromechancial instruments, components, and test equipment. Duties involve inspecting, removing, installing, repairing, operating, troubleshooting, overhauling, and modifying systems such as flight and…

  14. GASS: The Parkes Galactic All-Sky Survey. Update: improved correction for instrumental effects and new data release

    CERN Document Server

    Kalberla, Peter M W

    2015-01-01

    The Galactic All-Sky Survey is a survey of Galactic atomic hydrogen emission in the southern sky observed with the Parkes 64-m Radio Telescope. The first data release (GASS I) concerned survey goals and observing techniques, the second release (GASS II) focused on stray radiation and instrumental corrections. We seek to remove the remaining instrumental effects and present a third data release. We use the HEALPix tessellation concept to grid the data on the sphere. Individual telescope records are compared with averages on the nearest grid position for significant deviations. All averages are also decomposed into Gaussian components with the aim of segregating unacceptable solutions. Improved priors are used for an iterative baseline fitting and cleaning. In the last step we generate 3-D FITS data cubes and examine them for remaining problems. We have removed weak, but systematic baseline offsets with an improved baseline fitting algorithm. We have unraveled correlator failures that cause time dependent oscil...

  15. Development and measurement properties of the Orthotics and Prosthetics Users' Survey (OPUS): a comprehensive set of clinical outcome instruments.

    Science.gov (United States)

    Heinemann, A W; Bode, R K; O'Reilly, C

    2003-12-01

    The need to measure and evaluate orthotics and prosthetics (O&P) practice has received growing recognition in the past several years. Reliable and valid self-report instruments are needed that can help facilities evaluate patient outcomes. The objective of this project was to develop a set of self-report instruments that assess functional status, quality of life, and satisfaction with devices and services that can be used in an orthotics and prosthetics clinic. Selecting items from a variety of existing instruments, the authors developed and revised four instruments that differentiate patients with varying levels of lower limb function, quality of life, and satisfaction with devices and services. Evidence of construct validity is provided by hierarchies of item difficulty that are consistent with clinical experience. For example, with the lower limb function instrument, running one block was much more difficult than walking indoors. The instruments demonstrate adequate internal consistency (0.88 for lower limb function, 0.88 for quality of life, 0.74 for service satisfaction, 0.78 for device satisfaction). The next steps in their research programme are to evaluate sensitivity and construct validity. The Orthotics and Prosthetics Users' Survey (OPUS) is a promising self-report instrument which may, with further development, allow orthotic and prosthetic practitioners to evaluate the quality and effectiveness of their services as required by accreditation standards such as those of the American Board for Certification in Orthotics and Prosthetics that mandate quality assessment.

  16. New Instruments for Survey: on Line Softwares for 3d Recontruction from Images

    Science.gov (United States)

    Fratus de Balestrini, E.; Guerra, F.

    2011-09-01

    3d scanning technologies had a significant development and have been widely used in documentation of cultural, architectural and archeological heritages. Modern methods of three-dimensional acquiring and modeling allow to represent an object through a digital model that combines visual potentialities of images (normally used for documentation) to the accuracy of the survey, becoming at the same time support for the visualization that for metric evaluation of any artefact that have an historical or artistic interest, opening up new possibilities for cultural heritage's fruition, cataloging and study. Despite this development, because of the small catchment area and the 3D laser scanner's sophisticated technologies, the cost of these instruments is very high and beyond the reach of most operators in the field of cultural heritages. This is the reason why they have appeared low-cost technologies or even free, allowing anyone to approach the issues of acquisition and 3D modeling, providing tools that allow to create three-dimensional models in a simple and economical way. The research, conducted by the Laboratory of Photogrammetry of the University IUAV of Venice, of which we present here some results, is intended to figure out whether, with Arc3D, it is possible to obtain results that can be somehow comparable, in therms of overall quality, to those of the laser scanner, and/or whether it is possible to integrate them. They were carried out a series of tests on certain types of objects, models made with Arc3D, from raster images, were compared with those obtained using the point clouds from laser scanner. We have also analyzed the conditions for an optimal use of Arc3D: environmental conditions (lighting), acquisition tools (digital cameras) and type and size of objects. After performing the tests described above, we analyzed the patterns generated by Arc3D to check what other graphic representations can be obtained from them: orthophotos and drawings. The research

  17. NEW INSTRUMENTS FOR SURVEY: ON LINE SOFTWARES FOR 3D RECONTRUCTION FROM IMAGES

    Directory of Open Access Journals (Sweden)

    E. Fratus de Balestrini

    2012-09-01

    Full Text Available 3d scanning technologies had a significant development and have been widely used in documentation of cultural, architectural and archeological heritages. Modern methods of three-dimensional acquiring and modeling allow to represent an object through a digital model that combines visual potentialities of images (normally used for documentation to the accuracy of the survey, becoming at the same time support for the visualization that for metric evaluation of any artefact that have an historical or artistic interest, opening up new possibilities for cultural heritage's fruition, cataloging and study. Despite this development, because of the small catchment area and the 3D laser scanner's sophisticated technologies, the cost of these instruments is very high and beyond the reach of most operators in the field of cultural heritages. This is the reason why they have appeared low-cost technologies or even free, allowing anyone to approach the issues of acquisition and 3D modeling, providing tools that allow to create three-dimensional models in a simple and economical way. The research, conducted by the Laboratory of Photogrammetry of the University IUAV of Venice, of which we present here some results, is intended to figure out whether, with Arc3D, it is possible to obtain results that can be somehow comparable, in therms of overall quality, to those of the laser scanner, and/or whether it is possible to integrate them. They were carried out a series of tests on certain types of objects, models made with Arc3D, from raster images, were compared with those obtained using the point clouds from laser scanner. We have also analyzed the conditions for an optimal use of Arc3D: environmental conditions (lighting, acquisition tools (digital cameras and type and size of objects. After performing the tests described above, we analyzed the patterns generated by Arc3D to check what other graphic representations can be obtained from them: orthophotos and drawings

  18. Understanding nature's particle accelerators using high energy gamma-ray survey instruments

    Science.gov (United States)

    Abeysekara, Anushka Udara

    Nature's particle accelerators, such as Pulsars, Pulsar Wind Nebulae, Active Galactic Nuclei and Supernova Remnants accelerate charged particles to very high energies that then produce high energy photons. The particle acceleration mechanisms and the high energy photon emission mechanisms are poorly understood phenomena. These mechanisms can be understood either by studying individual sources in detail or, alternatively, using the collective properties of a sample of sources. Recent development of GeV survey instruments, such as Fermi-LAT, and TeV survey instruments, such as Milagro, provides a large sample of high energy gamma-ray flux measurements from galactic and extra-galactic sources. In this thesis I provide constraints on GeV and TeV radiation mechanisms using the X-ray-TeV correlations and GeV-TeV correlations. My data sample was obtained from three targeted searches for extragalactic sources and two targeted search for galactic sources, using the existing Milagro sky maps. The first extragalactic candidate list consists of Fermi-LAT GeV extragalactic sources, and the second extragalactic candidate list consists of TeVCat extragalactic sources that have been detected by Imaging Atmospheric Cerenkov Telescopes (IACTs). In both extragalactic candidate lists Markarian 421 was the only source detected by Milagro. A comparison between the Markarian 421 time-averaged flux, measured by Milagro, and the flux measurements of transient states, measured by IACTs, is discussed. The third extragalactic candidate list is a list of potential TeV emitting BL Lac candidates that was synthesized using X-ray observations of BL Lac objects and a Synchrotron Self-Compton model. Milagro's sensitivity was not sufficient to detect any of those candidates. However, the 95% confidence flux upper limits of those sources were above the predicted flux. Therefore, these results provide evidence to conclude that the Synchrotron Self-Compton model for BL Lac objects is still a viable

  19. Development and Validation of an Instrument for Assessing Climate Change Knowledge and Perceptions: The Climate Stewardship Survey (CSS)

    OpenAIRE

    Scott L. WALKER; McNeal, Karen S

    2013-01-01

    The Climate Stewardship Survey (CSS) was developed to measure knowledge and perceptions of global climate change, while also considering information sources that respondents ‘trust.’ The CSS was drafted using a three-stage approach: development of salient scales, writing individual items, and field testing and analyses. Construct validity and alpha-level reliability was conducted on the 122-item test instrument to produce a refined 84-item CSS.  The field tested C...

  20. Temperature performance of portable radiation survey instruments used for environmental monitoring and clean-up activities in Fukushima

    Science.gov (United States)

    Saegusa, Jun; Yanagisawa, Kayo; Hasumi, Atsushi; Shimizu, Takenori; Uchita, Yoshiaki

    2017-08-01

    Following the Fukushima Dai-ichi Nuclear Power Plant accident in March 2011, extensive radiation monitoring and environmental clean-up activities have been conducted throughout the Fukushima region. Outside air temperatures there reach 40 °C in summer and -20 °C in winter, which are beyond the quoted operational range of many radiation survey instruments. Herein, temperature performance of four types of portable Japanese radiation survey instruments widely used in Fukushima was experimentally investigated using a temperature-controlled chamber. They included two ionization chamber type instruments, Fuji NHA1 and Aloka ICS-323C, and two NaI(Tl) scintillation type ones, Fuji NHC7 and Aloka TCS-172B. Experimental results showed significantly diverse characteristics on the temperature dependences from one type of instrument to another. For example, NHA1 overestimated the ambient dose-equivalent rate by as much as 17% at -30 °C and 10% at 40 °C, whereas the TCS-172B readings underestimated the rate by 30% at -30 °C and 7% at 40 °C.

  1. Program Evaluation Using the Project Dakota Parent Satisfaction Survey. A Manual for Administration and Interpretation of Findings Using a Validated Instrument.

    Science.gov (United States)

    Kovach, JoAnne; Jacks, Robert

    This manual presents an instrument (the Dakota Parent Satisfaction Survey) and procedures for evaluating parent satisfaction with early intervention programs. The survey procedures have been used to evaluate seven early intervention programs each year since 1985. Development of the Survey is discussed, including the identification of program…

  2. Nutrition knowledge and Mediterranean diet adherence in the southeast United States: Validation of a field-based survey instrument.

    Science.gov (United States)

    Bottcher, Mary Rose; Marincic, Patricia Z; Nahay, Katie L; Baerlocher, Brittany E; Willis, Amy W; Park, Jieun; Gaillard, Philippe; Greene, Michael W

    2017-04-01

    The Mediterranean diet (MD) can reduce chronic disease risk and is a recommended diet for prevention and management of diabetes. Adherence to the MD in the southeast United States where obesity and diabetes are highly prevalent is unknown. The purpose of the present study was to: 1) construct a survey instrument relevant to the general population integrating both MD related nutrition knowledge and adherence questions from previously validated instruments, and 2) assess MD related nutrition knowledge and adherence in a sample population in the southest United States. Adherance was assessed using the validated short MD Adherence Screener (MEDAS). A MD nutrition knowledge (MDNK) questionnaire was developed from previously validated general nutrition knowledge questionnaires and was validated using 127 university students enrolled in three courses with varying levels of nutrition education. Cronbach's α for internal validity of MDNK was acceptable for a short questionnaire (0.653). Test-retest reliability was established (r = 0.853). Field validation of the three-part survey instrument (MEDAS, MDNK and demographic questions) was subsequently performed in 230 adults shopping at supermarkets and farmers markets in eastern Alabama. Total MDNK and MEDAS scores were significantly higher in students with formal nutrition education and in patrons of farmers markets. Greater MD adherence, assessed by dividing MEDAS scores into thirds, was found with increasing formal nutrition education in university students (p = 0.002) and in farmers market participants (p < 0.001). There was a weak but significant association between MDNK and MEDAS scores within university students and participants in the field. Together, the MDNK-MEDAS survey instrument is an effective tool for assessing baseline knowledge and adherence and can be used to target nutritional interventions to improve MD adherence for prevention and management of diabetes and other chronic disease.

  3. Measuring children's self-reported sport participation, risk perception and injury history: development and validation of a survey instrument.

    Science.gov (United States)

    Siesmaa, Emma J; Blitvich, Jennifer D; White, Peta E; Finch, Caroline F

    2011-01-01

    Despite the health benefits associated with children's sport participation, the occurrence of injury in this context is common. The extent to which sport injuries impact children's ongoing involvement in sport is largely unknown. Surveys have been shown to be useful for collecting children's injury and sport participation data; however, there are currently no published instruments which investigate the impact of injury on children's sport participation. This study describes the processes undertaken to assess the validity of two survey instruments for collecting self-reported information about child cricket and netball related participation, injury history and injury risk perceptions, as well as the reliability of the cricket-specific version. Face and content validity were assessed through expert feedback from primary and secondary level teachers and from representatives of peak sporting bodies for cricket and netball. Test-retest reliability was measured using a sample of 59 child cricketers who completed the survey on two occasions, 3-4 weeks apart. Based on expert feedback relating to face and content validity, modification and/or deletion of some survey items was undertaken. Survey items with low test-retest reliability (κ≤0.40) were modified or deleted, items with moderate reliability (κ=0.41-0.60) were modified slightly and items with higher reliability (κ≥0.61) were retained, with some undergoing minor modifications. This is the first survey of its kind which has been successfully administered to cricketers aged 10-16 years to collect information about injury risk perceptions and intentions for continued sport participation. Implications for its generalisation to other child sport participants are discussed.

  4. Assessing the Learning Environment for Medical Students: An Evaluation of a Novel Survey Instrument in Four Medical Schools.

    Science.gov (United States)

    Pololi, Linda H; Evans, Arthur T; Nickell, Leslie; Reboli, Annette C; Coplit, Lisa D; Stuber, Margaret L; Vasiliou, Vasilia; Civian, Janet T; Brennan, Robert T

    2017-06-01

    A practical, reliable, and valid instrument is needed to measure the impact of the learning environment on medical students' well-being and educational experience and to meet medical school accreditation requirements. From 2012 to 2015, medical students were surveyed at the end of their first, second, and third year of studies at four medical schools. The survey assessed students' perceptions of the following nine dimensions of the school culture: vitality, self-efficacy, institutional support, relationships/inclusion, values alignment, ethical/moral distress, work-life integration, gender equity, and ethnic minority equity. The internal reliability of each of the nine dimensions was measured. Construct validity was evaluated by assessing relationships predicted by our conceptual model and prior research. Assessment was made of whether the measurements were sensitive to differences over time and across institutions. Six hundred and eighty-six students completed the survey (49 % women; 9 % underrepresented minorities), with a response rate of 89 % (range over the student cohorts 72-100 %). Internal consistency of each dimension was high (Cronbach's α 0.71-0.86). The instrument was able to detect significant differences in the learning environment across institutions and over time. Construct validity was supported by demonstrating several relationships predicted by our conceptual model. The C-Change Medical Student Survey is a practical, reliable, and valid instrument for assessing the learning environment of medical students. Because it is sensitive to changes over time and differences across institution, results could potentially be used to facilitate and monitor improvements in the learning environment of medical students.

  5. The Mathematics Attitudes and Perceptions Survey: an instrument to assess expert-like views and dispositions among undergraduate mathematics students

    Science.gov (United States)

    Code, Warren; Merchant, Sandra; Maciejewski, Wes; Thomas, Matthew; Lo, Joseph

    2016-08-01

    One goal of an undergraduate education in mathematics is to help students develop a productive disposition towards mathematics. A way of conceiving of this is as helping mathematical novices transition to more expert-like perceptions of mathematics. This conceptualization creates a need for a way to characterize students' perceptions of mathematics in authentic educational settings. This article presents a survey, the Mathematics Attitudes and Perceptions Survey (MAPS), designed to address this need. We present the development of the MAPS instrument and its validation on a large (N = 3411) set of student data. Results from various MAPS implementations corroborate results from analogous instruments in other STEM disciplines. We present these results and highlight some in particular: MAPS scores correlate with course grades; students tend to move away from expert-like orientations over a semester or year of taking a mathematics course; and interactive-engagement type lectures have less of a negative impact, but no positive impact, on students' overall orientations than traditional lecturing. We include the MAPS instrument in this article and suggest ways in which it may deepen our understanding of undergraduate mathematics education.

  6. Nearest Neighbor Averaging and its Effect on the Critical Level and Minimum Detectable Concentration for Scanning Radiological Survey Instruments that Perform Facility Release Surveys.

    Energy Technology Data Exchange (ETDEWEB)

    Fournier, Sean Donovan; Beall, Patrick S; Miller, Mark L

    2014-08-01

    Through the SNL New Mexico Small Business Assistance (NMSBA) program, several Sandia engineers worked with the Environmental Restoration Group (ERG) Inc. to verify and validate a novel algorithm used to determine the scanning Critical Level (L c ) and Minimum Detectable Concentration (MDC) (or Minimum Detectable Areal Activity) for the 102F scanning system. Through the use of Monte Carlo statistical simulations the algorithm mathematically demonstrates accuracy in determining the L c and MDC when a nearest-neighbor averaging (NNA) technique was used. To empirically validate this approach, SNL prepared several spiked sources and ran a test with the ERG 102F instrument on a bare concrete floor known to have no radiological contamination other than background naturally occurring radioactive material (NORM). The tests conclude that the NNA technique increases the sensitivity (decreases the L c and MDC) for high-density data maps that are obtained by scanning radiological survey instruments.

  7. Use of electronic microprocessor-based instrumentation by the U.S. geological survey for hydrologic data collection

    Science.gov (United States)

    Shope, William G.; ,

    1991-01-01

    The U.S. Geological Survey is acquiring a new generation of field computers and communications software to support hydrologic data-collection at field locations. The new computer hardware and software mark the beginning of the Survey's transition from the use of electromechanical devices and paper tapes to electronic microprocessor-based instrumentation. Software is being developed for these microprocessors to facilitate the collection, conversion, and entry of data into the Survey's National Water Information System. The new automated data-collection process features several microprocessor-controlled sensors connected to a serial digital multidrop line operated by an electronic data recorder. Data are acquired from the sensors in response to instructions programmed into the data recorder by the user through small portable lap-top or hand-held computers. The portable computers, called personal field computers, also are used to extract data from the electronic recorders for transport by courier to the office computers. The Survey's alternative to manual or courier retrieval is the use of microprocessor-based remote telemetry stations. Plans have been developed to enhance the Survey's use of the Geostationary Operational Environmental Satellite telemetry by replacing the present network of direct-readout ground stations with less expensive units. Plans also provide for computer software that will support other forms of telemetry such as telephone or land-based radio.

  8. A systematic survey instrument translation process for multi-country, comparative health workforce studies

    NARCIS (Netherlands)

    Squires, A.; Aiken, L.H.; Heede, K. Van den; Sermeus, W.; Bruyneel, L.; Lindqvist, R.; Schoonhoven, L.; Stromseng, I.; Busse, R.; Brzostek, T.; Ensio, A.; Moreno-Casbas, M.; Rafferty, A.M.; Schubert, M.; Zikos, D.; Matthews, A.

    2013-01-01

    BACKGROUND: As health services research (HSR) expands across the globe, researchers will adopt health services and health worker evaluation instruments developed in one country for use in another. This paper explores the cross-cultural methodological challenges involved in translating HSR in the

  9. Measuring patient experiences with diabetes care in The Netherlands: the validity of a new survey instrument.

    NARCIS (Netherlands)

    Asbroek, G. ten; Delnoij, D.M.J.; Arah, O.A.; Sixma, H.; Koning, J.S. de; Rupp, I.; Poll, A.; Stam, P.J.A.; Schmidt, P.; Vriens, B.; Klazinga, N.S.

    2005-01-01

    Background: The introduction of market mechanisms in Dutch healthcare engages insurance companies in competition. Patient experience surveys are increasingly applied to generate performance information guiding consumers and insurers to choose and contract high performers, as well as holding them acc

  10. GASS: The Parkes Galactic All-Sky Survey. Update: improved correction for instrumental effects and new data release

    Science.gov (United States)

    Kalberla, P. M. W.; Haud, U.

    2015-06-01

    Context. The Galactic All-Sky Survey (GASS) is a survey of Galactic atomic hydrogen (H i) emission in the southern sky observed with the Parkes 64-m Radio Telescope. The first data release (GASS I) concerned survey goals and observing techniques, the second release (GASS II) focused on stray radiation and instrumental corrections. Aims: We seek to remove the remaining instrumental effects and present a third data release. Methods: We use the HEALPix tessellation concept to grid the data on the sphere. Individual telescope records are compared with averages on the nearest grid position for significant deviations. All averages are also decomposed into Gaussian components with the aim of segregating unacceptable solutions. Improved priors are used for an iterative baseline fitting and cleaning. In the last step we generate 3D FITS data cubes and examine them for remaining problems. Results: We have removed weak, but systematic baseline offsets with an improved baseline fitting algorithm. We have unraveled correlator failures that cause time dependent oscillations; errors cause stripes in the scanning direction. The remaining problems from radio frequency interference (RFI) are spotted. Classifying the severeness of instrumental errors for each individual telescope record (dump) allows us to exclude bad data from averages. We derive parameters that allow us to discard dumps without compromising the noise of the resulting data products too much. All steps are reiterated several times: in each case, we check the Gaussian parameters for remaining problems and inspect 3D FITS data cubes visually. We find that in total ~1.5% of the telescope dumps need to be discarded in addition to ~0.5% of the spectral channels that were excluded in GASS II. Conclusions: The new data release (GASS III) facilitates data products with improved quality. A new web interface, compatible with the previous version, is available for download of GASS III FITS cubes and spectra.

  11. Survey Instrument Development for Consumer Perception Testing to RTE Product in Convenience Store

    Directory of Open Access Journals (Sweden)

    Dyah Lestari Widaningrum

    2015-09-01

    Full Text Available Global trade and the abolition of trade barriers lead to the proliferation of imported food products such as various types of fast food products (RTE: ready-to-eat food sold by convenience stores mainly scattered in Jakarta. The question is what causes consumers choose certain convenience store to buy RTE Product and not choose another outlet category. To understand consumer perceptions, it is necessary to develop an instrument for measuring consumer perceptions of the option to purchase RTE Product at convenience stores. Variables used in this research are the perception and knowledge of the public/consumers against food safety, store attributes, service, and product attributes. The instrument used in this study is a questionnaire with a scalemeasuring1-5 to see the relationship between variables, we used the method of Structural Equation Modeling (SEM. The sample used in this study was 223 respondents that were divided into five areas in Jakarta, namely Central Jakarta, West Jakarta, South Jakarta, East Jakarta, and North Jakarta. The final outcome of the instrument development process was 25 observed variables, consisting of 4 indicators, which valid and reliable, with T-values for each observed variable is above 2,58, and Construct Reliability values range between 0,76 to 0,853.

  12. Proposing a survey instrument for measuring operational, formal, information and strategic Internet skills

    NARCIS (Netherlands)

    Deursen, van A.J.A.M.; Dijk, van J.A.G.M.; Peters, O.

    2012-01-01

    Observational studies prove to be very suitable to provide a realistic view of people's Internet skills. However, their cost and time are a strong limitation for large-scale data gathering. A useful addition to the measurement of Internet skills would be the development of survey questions for measu

  13. The Calern Asteroid Polarimetric Survey using the Torino polarimeter: assessment of instrument performances and first scientific results

    Science.gov (United States)

    Devogèle, M.; Cellino, A.; Bagnulo, S.; Rivet, J. P.; Bendjoya, P.; Abe, L.; Pernechele, C.; Massone, G.; Vernet, D.; Tanga, P.; Dimur, C.

    2017-03-01

    A new polarimeter based on the wedged double Wollaston concept has been built at the Torino Observatory and installed on a 1-m telescope at the Calern observing station of the Observatoire de la Côte d'Azur, France. Its main purpose is to carry out a polarimetric survey of minor Solar system objects, which is called the Calern Asteroid Polarimetric Survey. In this paper, we describe the new Torino polarimeter and the results of preliminary scientific validation tests. A number of standard stars with known polarization states, as well as a number of asteroids for which the polarimetric properties are known, have been observed in order to assess the instrument's accuracy. The instrumental polarization has been found to be stable within a few 10-4 units. A total of 124 new polarimetric observation of 78 asteroids are presented. In the case of asteroids already observed in the past, the new data are in agreement with available phase-polarization curves with error bars smaller than most previously published data. We also present data for 21 asteroids that have never been observed before in polarimetry.

  14. Survey of Hospitals and Manufacturers of Biomedical Instrumentation Concerning Variables Related to the Development and Implementation of a Bio-Med Instrumentation Technologist Curriculum.

    Science.gov (United States)

    Schaumberg, Gary F.

    The Bio-Med Instrumentation Technologist Questionnaire was sent to 105 hospitals in the Southern California area that had electronic instrumentation for patient monitoring purposes. Sixty completed questionnaires were returned. Twenty manufacturers of bio-medical instrumentation were sent the questionnaires and seven responded. Some of the…

  15. Development and testing of a survey instrument to measure benefits of a nursing information system.

    Science.gov (United States)

    Abdrbo, Amany A; Zauszniewski, Jaclene A; Hudak, Christine A; Anthony, Mary K

    2011-01-01

    Information systems (IS) benefits for nurses are outcomes related to the tangible products or improvements that nurses realize from using IS. This study examined the development and psychometric testing of a measure of nurses' benefits from IS. A random sample of 570 nurses working in hospitals, providing direct patient care, and using IS completed the study questionnaire. The internal consistency reliability of the results was .97. Exploratory factor analysis, using principal components extraction and varimax rotation, revealed items loaded on four factors (saving time and efficiency, quality of care, charting, and professional practice) that were confirmed by confirmatory factor analysis. Continued refinement of the instrument is needed with more diverse samples of nurses.

  16. Organizational member involvement in physical activity coalitions across the United States: development and testing of a novel survey instrument for assessing coalition functioning.

    Science.gov (United States)

    Bornstein, Daniel B; Pate, Russell R; Beets, Michael W; Saunders, Ruth P; Blair, Steven N

    2015-06-01

    Coalitions are often composed of member organizations. Member involvement is thought to be associated with coalition success. No instrument currently exists for evaluating organizational member involvement in physical activity coalitions. This study aimed to develop a survey instrument for evaluating organizational member involvement in physical activity coalitions. The study was carried out in three phases: (a) developing a draft survey, (b) assessing the content validity of the draft survey, and (c) assessing the underlying factor structure, reliability, and validity of the survey. A cross-sectional design was employed. In Phase 1, a team of experts in survey development produced a draft survey. In Phase 2, the content validity of the draft survey was evaluated by a panel of individuals with expertise in physical activity coalitions. In Phase 3, the survey was administered to 120 individuals on local-, state-, and national-level physical activity coalitions. Responses were subjected to an exploratory factor analysis in order to determine the survey's underlying factor structure, reliability, and validity. Phases 1 and 2yielded a survey instrument with demonstrated content validity. Phase 3 yielded a three-factor model with three subscales: Strategic Alignment, Organizational Alignment, and Providing Input. Each subscale demonstrated high internal consistency reliability and construct validity. The survey instrument developed here demonstrated sound psychometric properties and provides new insight into organizational member involvement in physical activity coalitions. This instrument may be an important tool in developing a more complete picture of coalition functioning in physical activity coalitions specifically and health-based coalitions overall. © 2014 Society for Public Health Education.

  17. Development of a respiratory protection survey instrument for occupational health nurses: an educational project.

    Science.gov (United States)

    Taormina, Deborah; Burgel, Barbara J

    2013-02-01

    The Institute of Medicine (2011) report Occupational Health Nurses and Respiratory Protection: Improving Education and Training outlined seven recommendations to improve the competency of occupational health nurses in respiratory protection. An advisory group was convened in December 2011, with stakeholder representation from the Centers for Disease Control and Prevention/National Institute for Occupational Safety and Health/National Personal Protective Technology Laboratory, American Association of Occupational Health Nurses, Inc., American Board for Occupational Health Nurses, Inc., Association of Occupational Health Professionals in Healthcare, American Nurses Association, and Institute of Medicine Standing Committee on Personal Protective Equipment for Workplace Safety and Health. The initial work of the advisory group included developing and administering a survey to assess current occupational health nurse roles and responsibilities relevant to respiratory protection. Development of the survey was led by a master's student and advisor who worked with the advisory group. The process of tool development and preliminary findings are presented in this article.

  18. A Survey of Commercially Available Chemical Agent Instrumentation for Use in the Field

    Energy Technology Data Exchange (ETDEWEB)

    Haas, J S; Alcaraz, A; Andresen, B D; Pruneda, C O

    2002-03-01

    Lawrence Livermore National Laboratory's (LLNL) Forensic Science Center (FSC) has extensive experience and capabilities in the analysis of chemical agents (CA) and related compounds as well as experience in identifying these materials in the field (i.e. samples such as those found in soils, liquids, gases). An open source survey was performed to determine viable, commercially available technology that can detect, in situ, CA and also meet field-use performance criteria as specified by the Program Management Consultant (PMC). The performance requirements of the technology include accuracy, reliability, integration onto robotics, and chemical detection sensitivities that meet required specifications. Not included in this survey are technologies and methodologies to detect CA decomposition products and related waste streams.

  19. NEW INSTRUMENTS FOR SURVEY: ON LINE SOFTWARES FOR 3D RECONTRUCTION FROM IMAGES

    OpenAIRE

    E. Fratus de Balestrini; Guerra, F.

    2012-01-01

    3d scanning technologies had a significant development and have been widely used in documentation of cultural, architectural and archeological heritages. Modern methods of three-dimensional acquiring and modeling allow to represent an object through a digital model that combines visual potentialities of images (normally used for documentation) to the accuracy of the survey, becoming at the same time support for the visualization that for metric evaluation of any artefact that have an historic...

  20. Measuring stigma among abortion providers: assessing the Abortion Provider Stigma Survey instrument.

    Science.gov (United States)

    Martin, Lisa A; Debbink, Michelle; Hassinger, Jane; Youatt, Emily; Eagen-Torkko, Meghan; Harris, Lisa H

    2014-01-01

    We explored the psychometric properties of 15 survey questions that assessed abortion providers' perceptions of stigma and its impact on providers' professional and personal lives referred to as the Abortion Provider Stigma Survey (APSS). We administered the survey to a sample of abortion providers recruited for the Providers' Share Workshop (N = 55). We then completed analyses using Stata SE/12.0. Exploratory factor analysis, which resulted in 13 retained items and identified three subscales: disclosure management, resistance and resilience, and discrimination. Stigma was salient in abortion provider's lives: they identified difficulties surrounding disclosure (66%) and felt unappreciated by society (89%). Simultaneously, workers felt they made a positive contribution to society (92%) and took pride in their work (98%). Paired t-test analyses of the pre- and post-Workshop APSS scores showed no changes in the total score. However, the Disclosure Management subscale scores were significantly lower (indicating decreased stigma) for two subgroups of participants: those over the age of 30 and those with children. This analysis is a promising first step in the development of a quantitative tool for capturing abortion providers' experiences of and responses to pervasive abortion stigma.

  1. [First stage of the cross-cultural adaptation of the instrument The Vulnerable Elders Survey (VES-13) to Portuguese].

    Science.gov (United States)

    Luz, Laércio Lima; Santiago, Lívia Maria; Silva, João Francisco Santos da; Mattos, Inês Echenique

    2013-03-01

    The aim of this study was to describe the initial stages of the cross-cultural adaptation of the instrument The Vulnerable Elders Survey (VES-13) for use in the context of cancer care in Brazil. Two translations into Portuguese and two back-translations into English were carried out independently, and a formal assessment of the general and referential meanings was performed in order to obtain a synthesis version. Understanding of the synthesis version was evaluated in a pretest applied to 33 patients in an oncologic hospital of the Brazilian Unified National Health System (SUS). The version was easily applied in the intended context and was well-accepted by elders. The Portuguese version of the VES-13 proved to be well understood and adequate for testing its psychometric qualities. The latter step is currently in the final phase.

  2. A survey on the high reliability software verification and validation technology for instrumentation and control in NPP.

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kee Choon; Lee, Chang Soo; Dong, In Sook [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-01-01

    This document presents the technical status of the software verification and validation (V and V) efforts to support developing and licensing digital instrumentation and control (I and C) systems in nuclear power plants. We have reviewed codes and standards to be concensus criteria among vendor, licensee and licenser. Then we have described the software licensing procedures under 10 CFR 50 and 10 CFR 52 of the United States cope with the licensing barrier. At last, we have surveyed the technical issues related to developing and licensing the high integrity software for digital I and C systems. These technical issues let us know the development direction of our own software V and V methodology. (Author) 13 refs., 2 figs.,.

  3. Modified ERT instrumentation for geo-scientific surveys in the historical centre of Mesagne (Brindisi, Southern Italy)

    Science.gov (United States)

    Leucci, Giovanni; De Giorgi, Lara; Terenzio Gizzi, Fabrizio; Persico, Raffaele

    2016-04-01

    The town of Mesagne is one of the sites at greatest geological risk in the north Salento peninsula. In the last few decades, the historical centre of Mesagne has been affected by a series of subsidence events, which have, in some cases, resulted in the partial collapse of buildings and road surfaces. The last event was in the January 2014. It caused subsidence phenomenon in a wide area and many families have been forced from their homes. These events have had both social repercussions, causing alarm and emergency situations, and economic repercussions in terms of the expense of restoration. In order to determine the causes of the ground subsidence events, integrated geophysical surveys were undertaken in the historical centre of Mesagne. In addition, the analysis of several wells allowed the 3D model reconstruction related both to the geology and to the groundwater depth in the surveyed areas. With the purpose of estimating the dimensions of the phenomenon and its possible relationship with both specific environmental conditions (for instance groundwater depth variation) and anthropic conditions (for instance the losses in water supply and sanitation) some geophysical measurements were repeated in the time. For this purpose a modified ERT instrumentation together GPR were used. The study led to the production of a detailed description of the subsidence causes that allows a quick action to restore security conditions in the area.

  4. Energy system comprising an electrochemical energy source

    NARCIS (Netherlands)

    Roozeboom, F.; Notten, P.

    2010-01-01

    The invention relates to an energy system comprising an electrochemical energy source, wherein said electrochemical energy source comprises at least one assembly of a first electrode, a second electrode, and an intermediate solid-state electrolyte separating said first electrode and said second elec

  5. Pressurizable structures comprising different surface sections

    NARCIS (Netherlands)

    Koussios, S.; Bergsma, O.K.; Beukers, A.

    2004-01-01

    The invention relates to composite pressurizable structures which are overwound with fibres or are braided. The pressurizable structures comprise axial sections which in turn comprise both concave and convex surfaces. The shape characteristics are related to geodesic as well as non-geodesic trajecto

  6. Developing a survey instrument to assess the readiness of primary care data, genetic and disease registries to conduct linked research: TRANSFoRm International Research Readiness (TIRRE survey instrument

    Directory of Open Access Journals (Sweden)

    Emily Leppenwell

    2013-05-01

    Full Text Available Background Clinical data are collected for routine care in family practice; there are also a growing number of genetic and cancer registry data repositories. The Translational Research and Patient Safety in Europe (TRANSFoRm project seeks to facilitate research using linked data from more than one source. We performed a requirements analysis which identified a wide range of data and business process requirements that need to be met before linking primary care and either genetic or disease registry data.Objectives To develop a survey to assess the readiness of data repositories to participate in linked research – the Transform International Research Readiness (TIRRE survey.Method We develop the questionnaire based on our requirement analysis; with questions at micro-, meso- and macro levels of granularity, study-specific questions about diabetes and gastro-oesophageal reflux disease (GORD, and research track record. The scope of the data required was extensive. We piloted this instrument, conducting ten preliminary telephone interviews to evaluate the response to the questionnaire.Results Using feedback gained from these interviews we revised the questionnaire; clarifying questions that were difficult to answer and utilising skip logic to create different series of questions for the various types of data repository. We simplified the questionnaire replacing free-text responses with yes/no or picking list options, wherever possible. We placed the final questionnaire online and encouraged its use (www.clininf.eu/jointirre/info.html.Conclusion Limited field testing suggests that TIRRE is capable of collecting comprehensive and relevant data about the suitability and readiness of data repositories to participate in linked data research.

  7. Patient experience and satisfaction with inpatient service: development of short form survey instrument measuring the core aspect of inpatient experience.

    Directory of Open Access Journals (Sweden)

    Eliza L Y Wong

    Full Text Available Patient experience reflects quality of care from the patients' perspective; therefore, patients' experiences are important data in the evaluation of the quality of health services. The development of an abbreviated, reliable and valid instrument for measuring inpatients' experience would reflect the key aspect of inpatient care from patients' perspective as well as facilitate quality improvement by cultivating patient engagement and allow the trends in patient satisfaction and experience to be measured regularly. The study developed a short-form inpatient instrument and tested its ability to capture a core set of inpatients' experiences. The Hong Kong Inpatient Experience Questionnaire (HKIEQ was established in 2010; it is an adaptation of the General Inpatient Questionnaire of the Care Quality Commission created by the Picker Institute in United Kingdom. This study used a consensus conference and a cross-sectional validation survey to create and validate a short-form of the Hong Kong Inpatient Experience Questionnaire (SF-HKIEQ. The short-form, the SF-HKIEQ, consisted of 18 items derived from the HKIEQ. The 18 items mainly covered relational aspects of care under four dimensions of the patient's journey: hospital staff, patient care and treatment, information on leaving the hospital, and overall impression. The SF-HKIEQ had a high degree of face validity, construct validity and internal reliability. The validated SF-HKIEQ reflects the relevant core aspects of inpatients' experience in a hospital setting. It provides a quick reference tool for quality improvement purposes and a platform that allows both healthcare staff and patients to monitor the quality of hospital care over time.

  8. A Frailty Instrument for primary care: findings from the Survey of Health, Ageing and Retirement in Europe (SHARE

    Directory of Open Access Journals (Sweden)

    Romero-Ortuno Roman

    2010-08-01

    Full Text Available Abstract Background A frailty paradigm would be useful in primary care to identify older people at risk, but appropriate metrics at that level are lacking. We created and validated a simple instrument for frailty screening in Europeans aged ≥50. Our study is based on the first wave of the Survey of Health, Ageing and Retirement in Europe (SHARE, http://www.share-project.org, a large population-based survey conducted in 2004-2005 in twelve European countries. Methods Subjects: SHARE Wave 1 respondents (17,304 females and 13,811 males. Measures: five SHARE variables approximating Fried's frailty definition. Analyses (for each gender: 1 estimation of a discreet factor (DFactor model based on the frailty variables using LatentGOLD®. A single DFactor with three ordered levels or latent classes (i.e. non-frail, pre-frail and frail was modelled; 2 the latent classes were characterised against a biopsychosocial range of Wave 1 variables; 3 the prospective mortality risk (unadjusted and age-adjusted for each frailty class was established on those subjects with known mortality status at Wave 2 (2007-2008 (11,384 females and 9,163 males; 4 two web-based calculators were created for easy retrieval of a subject's frailty class given any five measurements. Results Females: the DFactor model included 15,578 cases (standard R2 = 0.61. All five frailty indicators discriminated well (p N = 10,420; 66.9%, pre-frail (N = 4,025; 25.8%, and frail (N = 1,133; 7.3%. Relative to the non-frail class, the age-adjusted Odds Ratio (with 95% Confidence Interval for mortality at Wave 2 was 2.1 (1.4 - 3.0 in the pre-frail and 4.8 (3.1 - 7.4 in the frail. Males: 12,783 cases (standard R2 = 0.61, all frailty indicators had p N = 10,517; 82.3%, pre-frail (N = 1,871; 14.6%, and frail (N = 395; 3.1%; age-adjusted OR (95% CI for mortality: 3.0 (2.3 - 4.0 in the pre-frail, 6.9 (4.7 - 10.2 in the frail. Conclusions The SHARE Frailty Instrument has sufficient construct and

  9. Composition comprising lignin and antidi arrheal component

    DEFF Research Database (Denmark)

    2008-01-01

    The present invention relates to a composition comprising lignin and at least one compound selected from the group consisting of bromelain, papain, tannin, carvacrol, thymol, alliin, allicin, fenugreek seed, egg, poppy, poppy seeds, humic acid, roots, kaolin, catechu, cellulase, flavonoid...

  10. An optically guided microdevice comprising a nanowire

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to a microdevice (100) for emitting electromagnetic radiation onto an associated object. Simultaneous non-contact spatial control over the microdevice in terms of translational movement in three dimensions, and rotational movement around at least two axes, preferably...... three axes, is possible. The microdevice further comprises a nanowire (150) being arranged for emitting electromagnetic radiation onto said associated object. This is advantageous for obtaining better spatial control of the microdevice comprising the nanowire, and this enables that light could more...

  11. Engineering surveying theory and examination problems for students

    CERN Document Server

    Schofield, W

    2013-01-01

    Engineering Surveying: Theory and Examination Problems for Students, Volume 1, Third Edition discusses topics concerning engineering surveying techniques and instrumentations. The book is comprised of eight chapters that cover several concerns in engineering survey. Chapter 1 discusses the basic concepts of surveying. Chapter 2 deals with simple and precise leveling, while Chapter 3 covers earthworks. The book also talks about the theodolite and its applications, and then discusses optical distance measurement. Curves, underground and hydrographic surveying, and aspects of dimensional control

  12. Hearing aid comprising an array of microphones

    NARCIS (Netherlands)

    Boone, M.M.; Berkhout, A.J.; Merks, I.L.D.M.

    1999-01-01

    Hearing aid for improving the hearing ability of the hard of hearing, comprising an array of microphones, the electrical output signals of which are fed to at least one transmission path belonging to an ear. Means are provided for deriving two array output signals from the output signals of the micr

  13. Synthetic thermoelectric materials comprising phononic crystals

    Science.gov (United States)

    El-Kady, Ihab F; Olsson, Roy H; Hopkins, Patrick; Reinke, Charles; Kim, Bongsang

    2013-08-13

    Synthetic thermoelectric materials comprising phononic crystals can simultaneously have a large Seebeck coefficient, high electrical conductivity, and low thermal conductivity. Such synthetic thermoelectric materials can enable improved thermoelectric devices, such as thermoelectric generators and coolers, with improved performance. Such synthetic thermoelectric materials and devices can be fabricated using techniques that are compatible with standard microelectronics.

  14. Biocatalytic material comprising multilayer enzyme coated fiber

    Science.gov (United States)

    Kim, Jungbae [Richland, WA; Kwak, Ja Hun [Richland, WA; Grate, Jay W [West Richland, WA

    2009-11-03

    The present invention relates generally to high stability, high activity biocatalytic materials and processes for using the same. The materials comprise enzyme aggregate coatings having high biocatalytic activity and stability useful in heterogeneous environment. These new materials provide a new biocatalytic immobilized enzyme system with applications in bioconversion, bioremediation, biosensors, and biofuel cells.

  15. Development and pilot testing of an Internet-based survey instrument to measure the alcohol brand preferences of U.S. youth.

    Science.gov (United States)

    Siegel, Michael; DiLoreto, Joanna; Johnson, Andrea; Fortunato, Erin K; DeJong, William

    2011-04-01

    Although we know a great deal about the percentage of youth who drink alcohol, we know very little about the specific brands they choose to drink. This information gap needs to be addressed if public health officials are to develop more effective interventions. Unfortunately, there are no national youth surveys that collect data on alcohol brand consumption. In this paper, we describe the development and pilot testing of what we believe to be the first comprehensive, Internet-based youth survey of brand-specific alcohol use. We used online advertising in 3 U.S. cities to recruit a convenience sample of 241 respondents, ages 16 to 18 years. We used Craigslist, a network of online communities that features local classified advertisements, to recruit the sample. We used SurveyGizmo, an online software program for designing Internet surveys, collecting data, and performing basic analysis, to survey these respondents about their brand-specific alcohol consumption patterns. The survey instrument assessed each respondent's 30-day drinking history, including the frequency of consumption for each alcohol brand. Using Internet survey technology, we were able to collect information on 366 brands and still have respondents complete the instrument quickly and easily. The total number of brands consumed in the past 30 days ranged from 1 to 18, with a median of 4 brands. The top 5 brands consumed were beer brands, as were eleven of the top 15 brands. The remaining 4 brands in the top 15 included 3 brands of flavored alcoholic beverages and 1 brand of mixed drink. Among the top 15 alcohol brands consumed during heavy drinking episodes were 8 brands of beer, 4 brands of flavored alcoholic beverages, 2 brands of wine, and 1 brand of mixed drink. This pilot study helps establish the feasibility of including brand-specific questions on federal or other national youth alcohol surveys. Copyright © 2011 by the Research Society on Alcoholism.

  16. Results of a healthcare worker (HCW) survey on environmental awareness as an instrument for the preparation of an environmental report for the University Medicine Greifswald.

    Science.gov (United States)

    Heiden, Jens-Uwe; Kramer, Axel; Bornewasser, Manfred; Lemanski, Sandra; Below, Harald

    2011-01-01

    Environmental reporting is increasingly important for medical facilities. Currently, hospitals can determine the content of an environmental report as they see fit. To examine the utility and scope of an employee survey as an instrument for the preparation of an environmental report at the University Hospital Greifswald. For this purpose a questionnaire was developed with a focus on environmental behaviour and the significance attached to the protection of the environment. The employees of the University Medicine Greifswald attach an unexpectedly high significance to the protection of the environment. Based on this finding, this potential should be used to promote the optimal implementation of ecological-economic behaviour within the University Medicine. An employee survey is a useful instrument in the preparation of an environmental report.

  17. Nanophosphor composite scintillators comprising a polymer matrix

    Science.gov (United States)

    Muenchausen, Ross Edward; Mckigney, Edward Allen; Gilbertson, Robert David

    2010-11-16

    An improved nanophosphor composite comprises surface modified nanophosphor particles in a solid matrix. The nanophosphor particle surface is modified with an organic ligand, or by covalently bonding a polymeric or polymeric precursor material. The surface modified nanophosphor particle is essentially charge neutral, thereby preventing agglomeration of the nanophosphor particles during formation of the composite material. The improved nanophosphor composite may be used in any conventional scintillator application, including in a radiation detector.

  18. Evaluation of the two non-consecutive 24-h recall instrument for pan-European food consumption surveys

    NARCIS (Netherlands)

    Crispim, S.P.

    2011-01-01

    Background: The comparability of food consumption data originating from national nutritional surveys in Europe is currently hampered because of different methodologies used. Therefore, experts in the European Food Consumption Survey Method (EFCOSUM) consortium proposed to use two non-consecutive

  19. Method of forming a nanocluster-comprising dielectric layer and device comprising such a layer

    NARCIS (Netherlands)

    Kochupurackal, J.B.P.; Besling, W.F.A.; Klootwijk, J.H.; Wolters, A.M.; Roozeboom, F.

    2012-01-01

    A method of forming a dielectric layer on a further layer of a semiconductor device is disclosed. The method comprises depositing a dielectric precursor compound and a further precursor compound over the further layer, the dielectric precursor compound comprising a metal ion from the group consistin

  20. Conference Discussion: The Challenges in Multi-Object Spectroscopy Instrument and Survey Design, and in Data Processing and Analysis

    Science.gov (United States)

    Balcells, M.; Skillen, I.

    2016-10-01

    The final session of the conference Multi-Object Spectroscopy in the Next Decade: Big Questions, Large Surveys, and Wide Fields, held in La Palma 2-6 March 2015, was devoted to a discussion of the challenges in designing and operating the next-generation survey spectrographs, and planning and carrying out their massive surveys. The wide-ranging 1.5-hour debate was recorded on video tape, and in this paper we report the edited transcription of the dialog.

  1. Evaluation of the two non-consecutive 24-h recall instrument for pan-European food consumption surveys

    NARCIS (Netherlands)

    Crispim, S.P.

    2011-01-01

    Background: The comparability of food consumption data originating from national nutritional surveys in Europe is currently hampered because of different methodologies used. Therefore, experts in the European Food Consumption Survey Method (EFCOSUM) consortium proposed to use two non-consecutive 24-

  2. Insulating Materials Comprising Polysilazane, Methods of Forming Such Insulating Materials, and Precursor Formulations Comprising Polysilazane

    Science.gov (United States)

    Larson, Robert S. (Inventor); Fuller, Michael E. (Inventor)

    2013-01-01

    Methods of forming an insulating material comprising combining a polysilazane, a cross-linking compound, and a gas-generating compound to form a reaction mixture, and curing the reaction mixture to form a modified polysilazane. The gas-generating compound may be water, an alcohol, an amine, or combinations thereof. The cross-linking compound may be an isocyanate, an epoxy resin, or combinations thereof. The insulating material may include a matrix comprising one of a reaction product of a polysilazane and an isocyanate and a reaction product of a polysilazane and an epoxy resin. The matrix also comprises a plurality of interconnected pores produced from one of reaction of the polysilazane and the isocyanate and from reaction of the polysilazane and the epoxy resin. A precursor formulation that comprises a polysilazane, a cross-linking compound, and a gas-generating compound is also disclosed.

  3. Trends in caesarean section and instrumental deliveries in relation to Body Mass Index: a clinical survey during 1978 - 2001

    Directory of Open Access Journals (Sweden)

    Josefsson Ann

    2010-07-01

    Full Text Available Abstract Background During the last 20 years the rate of CS has increased in Sweden as it has in many other countries. The proportion of pregnant women suffering from a high BMI has also increased rapidly during the same time period. It would therefore be of interest to study both how and if these two observations are related to each other. The aim was therefore to study trends in mode of caesarean section (CS and instrumental deliveries among women in three BMI groups over a time span of almost 25 years with special focus on the observed body weight of pregnant women. Method The design is a retrospective cohort study using medical records of consecutively delivered women at two delivery wards in South East Sweden during the years 1978, 1986, 1992, 1997 and 2001. Results No significant time-trends were found for CS and instrumental delivery within each BMI-group for the time period studied. The proportion of women with BMI ≥ 25 delivered by means of CS or instrumental delivery increased quite dramatically from 1978 to 2001 (χ2 test for trend; p Conclusion Overweight and obese pregnant women constitute a rapidly growing proportion of the total number of CS and instrumental deliveries. Planning and allocation of health resources must be adjusted to this fact and its implications.

  4. The Development of a Survey Instrument on South Dakota's School District Leadership Climate as Related to Deming's Fourteen Points.

    Science.gov (United States)

    Holmes, Lawrence W. O.; And Others

    Development of an instrument to measure baseline levels of applied Total Quality Management (TQM) practices in South Dakota before the introduction and dissemination of TQM theory to the state's educational leaders is described. Using the interpretation of Deming's 14 points that was developed by J. J. Bonstigl, a 115-item initial item pool was…

  5. The balanced scorecard as a potential instrument for supporting planning and improvement in accounting education: Comparative survey findings

    Directory of Open Access Journals (Sweden)

    CJ Cronje

    2015-04-01

    Full Text Available This paper is firstly a comparison of the components of a potential balanced scorecard for accounting departments of universities in South Africa and Australia. Secondly, the various suggested measurement criteria of the balanced scorecard components are also compared. The findings of the research paper indicate no significant differences. The conclusion is that the balanced scorecard constitutes a potential instrument for supporting the planning and improvement of the accounting education environment.

  6. Market assessment for active solar heating and cooling products. Category B: A survey of decision makers in the HVAC market place. Survey instruments

    Energy Technology Data Exchange (ETDEWEB)

    Lilien, G. L.; Johnston, P. E.

    1980-09-01

    Telephone screener questionnaires and mail-out questionnaires for marketing surveys for solar heating and cooling equipment are presented. Questionnaires are included for the residential segment, industrial segment, HVAC professionals segment, builder/developer segment, and the commercial segment. No results are reported. (WHK)

  7. Development of a Survey Instrument to Measure TEFL Academics' Perceptions about, Individual and Workplace Characteristics for Conducting Research

    Science.gov (United States)

    Bai, Li; Hudson, Peter; Millwater, Jan; Tones, Megan

    2013-01-01

    A 30-item survey was devised to determine Chinese TEFL (Teaching English as a Foreign Language) academics' potential for conducting research. A five-part Likert scale was used to gather data from 182 academics on four factors: (1) perceptions on teaching-research nexus, (2) personal perspectives for conducting research, (3) predispositions for…

  8. Relationships Among the Knowledge, Efficacy, and Practices Instrument, Color-Blind Racial Attitudes Scale, Deamonte Driver Survey, and Defining Issues Test 2.

    Science.gov (United States)

    Behar-Horenstein, Linda S; Garvan, Cynthia W

    2016-03-01

    Concordance studies indicate the degree to which instruments measure the same or similar constructs or something different. The aims of this study were to identify the factor structure of the Deamonte Driver Survey and determine the relationship between the Deamonte Driver (a measure of social class stereotyping), the Defining Issues Test 2 (DIT2; a measure of ethical sensitivity), the Color-Blind Racial Attitudes Scale (CoBRAS; a measure of racial stereotyping), and the Knowledge, Efficacy, and Practices Instrument (KEPI; a measure of cultural competence). The results showed a three-factor solution for the Deamonte Driver Survey and significant relationships between CoBRAS and DIT2 subscales and between CoBRAS and Deamonte Driver subscales. Significant relationships between the measures and exploratory variables, underrepresented minority status, age, citizenship, marital status, political stance, English as a first language, and gender were found. The lack of a significant relationship between the KEPI and Deamonte Driver, DIT2, or CoBRAS subscales suggests that the KEPI is measuring a unique construct. These findings showed how these scales contributed to the assessment of cultural competence among dental students and faculty.

  9. An analysis of determinants influencing use of ayurvedic medication in Pune region utilizing a questionnaire survey instrument

    Directory of Open Access Journals (Sweden)

    Vyawahare Neeraj

    2009-01-01

    The survey revealed that consumption of Ayurvedic medication in Pune region is increasing, wherein safety and faith are important parameters, however, like allopathic medication; people usually stick to the prescription issued by the physician. The increasing trend of self medication and lack of knowledge of herb drug interaction especially in non graduates are the major concerns need to be addressed for better outcome of the therapy.

  10. Validation of a survey instrument to assess home environments for physical activity and healthy eating in overweight children

    Directory of Open Access Journals (Sweden)

    Crane Lori A

    2008-01-01

    Full Text Available Abstract Background Few measures exist to measure the overall home environment for its ability to support physical activity (PA and healthy eating in overweight children. The purpose of this study was to develop and test the reliability and validity of such a measure. Methods The Home Environment Survey (HES was developed to reflect availability, accessibility, parental role modelling, and parental policies related to PA resources, fruits and vegetables (F&V, and sugar sweetened drinks and snacks (SS. Parents of overweight children (n = 219 completed the HES and concurrent behavioural assessments. Children completed the Block Kids survey and wore an accelerometer for one week. A subset of parents (n = 156 completed the HES a second time to determine test-retest reliability. Finally, 41 parent dyads living in the same home (n = 41 completed the survey to determine inter-rater reliability. Initial psychometric analyses were completed to trim items from the measure based on lack of variability in responses, moderate or higher item to scale correlation, or contribution to strong internal consistency. Inter-rater and test-retest reliability were completed using intraclass correlation coefficients. Validity was assessed using Pearson correlations between the HES scores and child and parent nutrition and PA. Results Eight items were removed and acceptable internal consistency was documented for all scales (α = .66–84 with the exception of the F&V accessibility. The F&V accessibility was reduced to a single item because the other two items did not meet reliability standards. Test-retest reliability was high (r > .75 for all scales. Inter-rater reliability varied across scales (r = .22–.89. PA accessibility, parent role modelling, and parental policies were all related significantly to child (r = .14–.21 and parent (r = .15–.31 PA. Similarly, availability of F&V and SS, parental role modelling, and parental policies were related to child (r

  11. Effect of survey instrument on participation in a follow-up study: a randomization study of a mailed questionnaire versus a computer-assisted telephone interview

    Directory of Open Access Journals (Sweden)

    Rocheleau Carissa M

    2012-07-01

    Full Text Available Abstract Background Many epidemiological and public health surveys report increasing difficulty obtaining high participation rates. We conducted a pilot follow-up study to determine whether a mailed or telephone survey would better facilitate data collection in a subset of respondents to an earlier telephone survey conducted as part of the National Birth Defects Prevention Study. Methods We randomly assigned 392 eligible mothers to receive a self-administered, mailed questionnaire (MQ or a computer-assisted telephone interview (CATI using similar recruitment protocols. If mothers gave permission to contact the fathers, fathers were recruited to complete the same instrument (MQ or CATI as mothers. Results Mothers contacted for the MQ, within all demographic strata examined, were more likely to participate than those contacted for the CATI (86.6% vs. 70.6%. The median response time for mothers completing the MQ was 17 days, compared to 29 days for mothers completing the CATI. Mothers completing the MQ also required fewer reminder calls or letters to finish participation versus those assigned to the CATI (median 3 versus 6, though they were less likely to give permission to contact the father (75.0% vs. 85.8%. Fathers contacted for the MQ, however, had higher participation compared to fathers contacted for the CATI (85.2% vs. 54.5%. Fathers recruited to the MQ also had a shorter response time (median 17 days and required fewer reminder calls and letters (median 3 reminders than those completing the CATI (medians 28 days and 6 reminders. Conclusions We concluded that offering a MQ substantially improved participation rates and reduced recruitment effort compared to a CATI in this study. While a CATI has the advantage of being able to clarify answers to complex questions or eligibility requirements, our experience suggests that a MQ might be a good survey option for some studies.

  12. The Swiss Health Literacy Survey: development and psychometric properties of a multidimensional instrument to assess competencies for health

    Science.gov (United States)

    Wang, Jen; Thombs, Brett D.; Schmid, Margareta R.

    2012-01-01

    Abstract Background  Growing recognition of the role of citizens and patients in health and health care has placed a spotlight on health literacy and patient education. Objective  To identify specific competencies for health in definitions of health literacy and patient‐centred concepts and empirically test their dimensionality in the general population. Methods  A thorough review of the literature on health literacy, self‐management, patient empowerment, patient education and shared decision making revealed considerable conceptual overlap as competencies for health and identified a corpus of 30 generic competencies for health. A questionnaire containing 127 items covering the 30 competencies was fielded as a telephone interview in German, French and Italian among 1255 respondents randomly selected from the resident population in Switzerland. Findings  Analyses with the software MPlus to model items with mixed response categories showed that the items do not load onto a single factor. Multifactorial models with good fit could be erected for each of five dimensions defined a priori and their corresponding competencies: information and knowledge (four competencies, 17 items), general cognitive skills (four competencies, 17 items), social roles (two competencies, seven items), medical management (four competencies, 27 items) and healthy lifestyle (two competencies, six items). Multiple indicators and multiple causes models identified problematic differential item functioning for only six items belonging to two competencies. Conclusions  The psychometric analyses of this instrument support broader conceptualization of health literacy not as a single competence but rather as a package of competencies for health. PMID:22390287

  13. Hydrocarbon recovery comprising injecting a slug comprising oil soluble alkoxylated surfactants from lignin

    Energy Technology Data Exchange (ETDEWEB)

    Naae, D.G.; DaGue, M.G.; Dunn, N.G.

    1993-07-27

    A method is described of recovering hydrocarbons from an underground hydrocarbon formation penetrated by at least one injection well and at least one production well, which comprises: injecting into the formation through an injection well a surfactant slug comprising about 0.1% to about 10% by weight of oil soluble surfactants produced from lignin, said oil soluble surfactants produced by placing lignin in contact with water, converting the lignin into relatively low molecular weight lignin phenols by reducing the lignin in the presence of a reducing agent of carbon monoxide or hydrogen, said reduction occurring at a temperature greater than about 200 C and a pressure greater than about 100 psi, recovering the oil soluble lignin phenols from the reaction mixture, alkoxylating the lignin phenols by reacting the lignin phenols with an a-olefin epoxide having about 6 to about 20 carbon atoms at about 100 to about 200 C for about 1 to about 3 hours in an organic solvent, and changing the alkoxylated lignin phenols into oil soluble lignin surfactants by a reaction selected from the group consisting of sulfonation, sulfation, and alkoxysulfation; injecting into the formation through the injection well a drive fluid to push the surfactant slug towards a production well; and recovering hydrocarbons at the production well.

  14. Development and testing of the Survey of Family Environment (SFE): a novel instrument to measure family functioning and needs for family support.

    Science.gov (United States)

    Hohashi, Naohiro; Honda, Junko

    2012-01-01

    Hohashi's Concentric Sphere Family Environment Model (CSFEM; Hohashi & Honda, 2011) is a newly proposed family nursing theory for holistically understanding the family environment that acts on family well-being. The purpose of this article is to develop and psychometrically test the Japanese version of the Survey of Family Environment (SFE-J), grounded in the CSFEM, for measuring family's perceived family functioning and family's perceived needs for family support. The SFE-J is a 30-item self-administered instrument that assesses five domains (suprasystem, macrosystem, microsystem, family internal environment system, and chronosystem) and has been subjected to rigorous reliability and validity investigations among paired partners in child-rearing families (N of family = 1,990). Internal consistency reliability was high as measured by Cronbach's alpha coefficients. Temporal stability over a 2-week interval was supported by high (substantial or perfect) and significant intraclass correlation coefficients. The total score for the SFE-J was significantly correlated with the Japanese version of the Feetham Family Functioning Survey (FFFS-J), indicating an acceptable concurrent validity. Construct validity was supported by a confirmatory factor analysis that evaluated the five-factor structure to measure the concept of CSFEM. Results also demonstrate that the SFE-J family functioning scores show no significant differences between paired partners. The SFE-J is a reliable and valid instrument to assess not only intrafamily functioning but also interfamily functioning and, by identifying items/domains with high requirements for family support, serves to facilitate the providing of appropriate support to families.

  15. Compositions Comprising Nickel-Titanium, Methods Manufacture Thereof and Articles Comprising the Same

    Science.gov (United States)

    Glennon, Glenn N. (Inventor); DellaCorte, Christopher (Inventor)

    2016-01-01

    Disclosing herein is a method for manufacturing nickel-titanium compositions. The method includes disposing a powdered composition in a mold; the powdered composition comprising nickel and titanium; the titanium being present in an amount of about 38 to about 42 wt % and the nickel being present in an amount of about 58 to about 62 wt %; sintering the powdered composition to produce a sintered preform; compacting the preform; machining the preform to form an article; heat treating the article; the annealing being conducted at a temperature of about 1650.degree. F. to about 1900.degree. F. at a pressure of about 3 Torr to about 5 Kg-f/cm.sup.2 for a time period of about 10 minutes to about 5 hours; and quenching the article.

  16. Instrumentation in Earthquake Seismology

    Science.gov (United States)

    Havskov, Jens; Alguacil, Gerardo

    Here is unique and comprehensive coverage of modern seismic instrumentation, based on the authors' practical experience of a quarter-century in seismology and geophysics. Their goal is to provide not only detailed information on the basics of seismic instruments but also to survey equipment on the market, blending this with only the amount of theory needed to understand the basic principles. Seismologists and technicians working with seismological instruments will find here the answers to their practical problems.

  17. [Survey of analytical works for drugs at emergency and critical care centers with high-performance instruments provided by the Ministry of Health and Welfare (at present: Ministry of Health, Labour, and Welfare) in fiscal 1998--continuation of survey with 2008 survey results as point of reference].

    Science.gov (United States)

    Saito, Takeshi; Tominaga, Aya; Nozawa, Mayu; Unei, Hiroko; Hatano, Yayoi; Fujita, Yuji; Iseki, Ken; Hori, Yasushi

    2013-09-01

    In a 2008 survey of the 73 emergency and critical care centers around the nation that were equipped with the drug and chemical analytical instrument provided by the Ministry of Welfare (currently the Ministry of Health, Labour, and Welfare) in 1998, 36 of those facilities were using the analytical instruments. Of these 36 facilities, a follow-up survey of the 17 facilities that recorded 50 or analyses per year. Responses were gained from 16 of the facilities and we learned that of those, 14 facilities (87.5%) were conducting analyses using the instrument. There was a positive mutual correlation between the annual number of cases of the 14 facilities conducting analyses with the instrument and the number of work hours. Depending on the instrument in use, average analytical instrument parts and maintenance expenses were roughly three million yen and consumables required a maximum three million yen for analysis of 51-200 cases per year. From this, we calculate that such expenses can be covered under the allowed budget for advanced emergency and critical care centers of 5,000 NHI points (1 point = 10 yen). We found there were few facilities using the instrument for all 15 of the toxic substances recommended for testing by the Japanese Society for Clinical Toxicology. There tended to be no use of the analytical instrument for compounds with no toxicology cases. However, flexible responses were noted at each facility in relation to frequently analyzed compounds. It is thought that a reevaluation of compounds subject to analysis is required.

  18. Coated silicon comprising material for protection against environmental corrosion

    Science.gov (United States)

    Hazel, Brian Thomas (Inventor)

    2009-01-01

    In accordance with an embodiment of the invention, an article is disclosed. The article comprises a gas turbine engine component substrate comprising a silicon material; and an environmental barrier coating overlying the substrate, wherein the environmental barrier coating comprises cerium oxide, and the cerium oxide reduces formation of silicate glass on the substrate upon exposure to corrodant sulfates.

  19. Jones' instrument technology

    CERN Document Server

    Jones, Ernest Beachcroft; Kingham, Edward G; Radnai, Rudolf

    1985-01-01

    Jones' Instrument Technology, Volume 5: Automatic Instruments and Measuring Systems deals with general trends in automatic instruments and measuring systems. Specific examples are provided to illustrate the principles of such devices. A brief review of a considerable number of standards is undertaken, with emphasis on the IEC625 Interface System. Other relevant standards are reviewed, including the interface and backplane bus standards. This volume is comprised of seven chapters and begins with a short introduction to the principles of automatic measurements, classification of measuring system

  20. SURVEY

    DEFF Research Database (Denmark)

    SURVEY er en udbredt metode og benyttes inden for bl.a. samfundsvidenskab, humaniora, psykologi og sundhedsforskning. Også uden for forskningsverdenen er der mange organisationer som f.eks. konsulentfirmaer og offentlige institutioner samt marketingsafdelinger i private virksomheder, der arbejder...... med surveys. Denne bog gennemgår alle surveyarbejdets faser og giver en praktisk indføring i: • design af undersøgelsen og udvælgelse af stikprøver, • formulering af spørgeskemaer samt indsamling og kodning af data, • metoder til at analysere resultaterne...

  1. OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. V. TOWARD AN EMPIRICAL METAL-POOR MASS–LUMINOSITY RELATION

    Energy Technology Data Exchange (ETDEWEB)

    Horch, Elliott P. [Department of Physics, Southern Connecticut State University, 501 Crescent Street, New Haven, CT 06515 (United States); Van Altena, William F.; Demarque, Pierre [Department of Astronomy, Yale University P.O. Box 208101, New Haven, CT 06520-8101 (United States); Howell, Steve B. [NASA Ames Research Center, Moffett Field, CA 94035 (United States); Everett, Mark E. [National Optical Astronomy Observatory, 950 North Cherry Avenue, Tucson, AZ 85719 (United States); Ciardi, David R. [NASA Exoplanet Science Institute, California Institute of Technology, 770 South Wilson Avenue, Mail Code 100-22, Pasadena, CA 91125 (United States); Teske, Johanna K. [Department of Terrestrial Magnetism and Carnegie Observatories, Carnegie Institute of Washington, 5241 Broad Branch Road, NW, Washington, DC 20015 (United States); Henry, Todd J.; Winters, Jennifer G., E-mail: horche2@southernct.edu, E-mail: william.vanaltena@yale.edu, E-mail: pierre.demarque@yale.edu, E-mail: steve.b.howell@nasa.gov, E-mail: everett@noao.edu, E-mail: ciardi@ipac.caltech.edu, E-mail: jteske@carnegiescience.edu, E-mail: thenry@astro.gsu.edu, E-mail: winters@astro.gsu.edu [Department of Physics and Astronomy, Georgia State University, Atlanta, GA 30302 (United States)

    2015-05-15

    In an effort to better understand the details of the stellar structure and evolution of metal-poor stars, the Gemini North telescope was used on two occasions to take speckle imaging data of a sample of known spectroscopic binary stars and other nearby stars in order to search for and resolve close companions. The observations were obtained using the Differential Speckle Survey Instrument, which takes data in two filters simultaneously. The results presented here are of 90 observations of 23 systems in which one or more companions was detected, and six stars where no companion was detected to the limit of the camera capabilities at Gemini. In the case of the binary and multiple stars, these results are then further analyzed to make first orbit determinations in five cases, and orbit refinements in four other cases. The mass information is derived, and since the systems span a range in metallicity, a study is presented that compares our results with the expected trend in total mass as derived from the most recent Yale isochrones as a function of metal abundance. These data suggest that metal-poor main-sequence stars are less massive at a given color than their solar-metallicity analogues in a manner consistent with that predicted from the theory.

  2. Observations of Binary Stars with the Differential Speckle Survey Instrument. V. Toward an Empirical Metal-Poor Mass-Luminosity Relation

    Science.gov (United States)

    Horch, Elliott P.; van Altena, William F.; Demarque, Pierre; Howell, Steve B.; Everett, Mark E.; Ciardi, David R.; Teske, Johanna K.; Henry, Todd J.; Winters, Jennifer G.

    2015-05-01

    In an effort to better understand the details of the stellar structure and evolution of metal-poor stars, the Gemini North telescope was used on two occasions to take speckle imaging data of a sample of known spectroscopic binary stars and other nearby stars in order to search for and resolve close companions. The observations were obtained using the Differential Speckle Survey Instrument, which takes data in two filters simultaneously. The results presented here are of 90 observations of 23 systems in which one or more companions was detected, and six stars where no companion was detected to the limit of the camera capabilities at Gemini. In the case of the binary and multiple stars, these results are then further analyzed to make first orbit determinations in five cases, and orbit refinements in four other cases. The mass information is derived, and since the systems span a range in metallicity, a study is presented that compares our results with the expected trend in total mass as derived from the most recent Yale isochrones as a function of metal abundance. These data suggest that metal-poor main-sequence stars are less massive at a given color than their solar-metallicity analogues in a manner consistent with that predicted from the theory.

  3. Observations of Binary Stars with the Differential Speckle Survey Instrument. V. Toward an Empirical Metal-Poor Mass-Luminosity Relation

    CERN Document Server

    Horch, Elliott P; Demarque, Pierre; Howell, Steve B; Everett, Mark E; Ciardi, David R; Teske, Johanna K; Henry, Todd J; Winters, Jennifer G

    2015-01-01

    In an effort to better understand the details of the stellar structure and evolution of metal poor stars, the Gemini North telescope was used on two occasions to take speckle imaging data of a sample of known spectroscopic binary stars and other nearby stars in order to search for and resolve close companions. The observations were obtained using the Differential Speckle Survey Instrument, which takes data in two filters simultaneously. The results presented here are of 90 observations of 23 systems in which one or more companions was detected, and 6 stars where no companion was detected to the limit of the camera capabilities at Gemini. In the case of the binary and multiple stars, these results are then further analyzed to make first orbit determinations in five cases, and orbit refinements in four other cases. Mass information is derived, and since the systems span a range in metallicity, a study is presented that compares our results with the expected trend in total mass as derived from the most recent Ya...

  4. Compositions comprising enhanced graphene oxide structures and related methods

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Priyank Vijaya; Bardhan, Neelkanth M.; Belcher, Angela; Grossman, Jeffrey

    2016-12-27

    Embodiments described herein generally relate to compositions comprising a graphene oxide species. In some embodiments, the compositions advantageously have relatively high oxygen content, even after annealing.

  5. Compositions comprising enhanced graphene oxide structures and related methods

    Science.gov (United States)

    Kumar, Priyank Vijaya; Bardhan, Neelkanth M.; Belcher, Angela; Grossman, Jeffrey

    2016-12-27

    Embodiments described herein generally relate to compositions comprising a graphene oxide species. In some embodiments, the compositions advantageously have relatively high oxygen content, even after annealing.

  6. Validity and reliability of the Patient-Reported Arthralgia Inventory: validation of a newly-developed survey instrument to measure arthralgia

    Directory of Open Access Journals (Sweden)

    Castel LD

    2015-07-01

    Full Text Available Liana D Castel,1 Kenneth A Wallston,2 Benjamin R Saville,3 JoAnn R Alvarez,3 Bradley D Shields,4 Irene D Feurer,3 David Cella5 1Meharry-Vanderbilt Alliance, Nashville, TN, USA; 2Psychology in Nursing, Vanderbilt University School of Nursing, Nashville, TN, USA; 3Surgery and Biostatistics, Vanderbilt University School of Medicine, Nashville, TN, USA; 4Medical Sciences, University of Arkansas School of Medicine, Little Rock, AR, USA; 5Medical Social Sciences, Northwestern University Feinberg School of Medicine, Chicago, IL, USA Background: There is a need for a survey instrument to measure arthralgia (joint pain that has been psychometrically validated in the context of existing reference instruments. We developed the 16-item Patient-Reported Arthralgia Inventory (PRAI to measure arthralgia severity in 16 joints, in the context of a longitudinal cohort study to assess aromatase inhibitor-associated arthralgia in breast cancer survivors and arthralgia in postmenopausal women without breast cancer. We sought to evaluate the reliability and validity of the PRAI instrument in these populations, as well as to examine the relationship of patient-reported morning stiffness and arthralgia. Methods: We administered the PRAI on paper in 294 women (94 initiating aromatase inhibitor therapy and 200 postmenopausal women without breast cancer at weeks 0, 2, 4, 6, 8, 12, 16, and 52, as well as once in 36 women who had taken but were no longer taking aromatase inhibitor therapy. Results: Cronbach's alpha was 0.9 for internal consistency of the PRAI. Intraclass correlation coefficients of test-retest reliability were in the range of 0.87–0.96 over repeated PRAI administrations; arthralgia severity was higher in the non-cancer group at baseline than at subsequent assessments. Women with joint comorbidities tended to have higher PRAI scores than those without (estimated difference in mean scores: -0.3, 95% confidence interval [CI] -0.5, -0.2; P<0.001. The PRAI was

  7. Radioisotope instruments

    CERN Document Server

    Cameron, J F; Silverleaf, D J

    1971-01-01

    International Series of Monographs in Nuclear Energy, Volume 107: Radioisotope Instruments, Part 1 focuses on the design and applications of instruments based on the radiation released by radioactive substances. The book first offers information on the physical basis of radioisotope instruments; technical and economic advantages of radioisotope instruments; and radiation hazard. The manuscript then discusses commercial radioisotope instruments, including radiation sources and detectors, computing and control units, and measuring heads. The text describes the applications of radioisotop

  8. Charge pump DC-DC converter comprising solid state batteries

    NARCIS (Netherlands)

    Reefman, D.; Roozeboom, F.; Notten, P.H.L.; Klootwijk, J.H.

    2013-01-01

    An electronic device is provided which comprises a DC-DC converter. The DC-DC converter comprises at least one solid-state rechargeable battery (B1, B2) for storing energy for the DC-DC conversion and an output capacitor (C2).

  9. Medical preparation container comprising microwave powered sensor assembly

    DEFF Research Database (Denmark)

    2016-01-01

    The present invention relates to a medical preparation container which comprises a microwave powered sensor assembly. The microwave powered sensor assembly comprises a sensor configured to measure a physical property or chemical property of a medical preparation during its heating in a microwave...

  10. Immunogenic compositions comprising human immunodeficiency virus (HIV) mosaic Nef proteins

    Science.gov (United States)

    Korber, Bette T [Los Alamos, NM; Perkins, Simon [Los Alamos, NM; Bhattacharya, Tanmoy [Los Alamos, NM; Fischer, William M [Los Alamos, NM; Theiler, James [Los Alamos, NM; Letvin, Norman [Boston, MA; Haynes, Barton F [Durham, NC; Hahn, Beatrice H [Birmingham, AL; Yusim, Karina [Los Alamos, NM; Kuiken, Carla [Los Alamos, NM

    2012-02-21

    The present invention relates to mosaic clade M HIV-1 Nef polypeptides and to compositions comprising same. The polypeptides of the invention are suitable for use in inducing an immune response to HIV-1 in a human.

  11. An endoplasmic reticulum (ER)-directed fusion protein comprising a ...

    African Journals Online (AJOL)

    An endoplasmic reticulum (ER)-directed fusion protein comprising a bacterial subtilisin ... which are used for the commercial production of therapeutic proteins. ... expression platforms) to purify recombinant proteins in crude plant extracts.

  12. Metal-polymer composites comprising nanostructures and applications thereof

    Science.gov (United States)

    Wang, Hsing-Lin; Jeon, Sea Ho; Mack, Nathan H.

    2011-08-02

    Metal-polymer composites, and methods of making and use thereof, said composites comprising a thermally-cured dense polyaniline substrate; an acid dopant; and, metal nanostructure deposits wherein the deposits have a morphology dependent upon the acid dopant.

  13. Dielectric electroactive polymers comprising an ionic supramolecular structure

    DEFF Research Database (Denmark)

    2014-01-01

    The present invention relates to an ionic interpenetrating polymer network comprising at least one elastomer and an ionic supramolecular structure comprising the reaction product of at least two chemical compounds wherein each of said compounds has at least two functional groups and wherein said ...... compounds are able to undergo Lewis acid-base reactions. The interpenetrating polymer network may be used as dielectric electroactive polymers (DEAPs) having a high dielectric permittivity....

  14. 星源通掌上森林调查仪面积测量精度研究%A Study of Area Survey Precision Based on Xingyuantong Handhold Forest Inventory Instrument

    Institute of Scientific and Technical Information of China (English)

    李崇贵; 陈华安; 李春干

    2005-01-01

    Xingyuangtong handhold forest inventory instrument is a microcomputer-based Hi-tech product integrating remote sensing, mobile GIS and GPS, which is developed by 3S research center of Shenzhen Polytechnic. It can be used in forest resource inventory, area calculation on map, area survey on the spot, compartment and sub-compartment mapping and editing based on remote sensing images or scanned relief maps, interactive query and amendment between graphics and its attributes,etc. On the basis of theory analysis of area survey principle, the practical area survey precision of nine different-sized plots in different period of time and under different interfered conditions is analyzed in order to study the possible precision of area survey on the spot by using this product. It is demonstrated that Xinyuantong handhold forest resource inventory instrument can meet the precision needs of returning the grain plots to forestry, acceptance check of forestation land, area survey of compartment and subcompartment, etc. This product can be widely used in forest resource inventory.

  15. Compositions, methods, and systems comprising fluorous-soluble polymers

    Science.gov (United States)

    Swager, Timothy M.; Lim, Jeewoo; Takeda, Yohei

    2015-10-13

    The present invention generally relates to compositions, methods, and systems comprising polymers that are fluorous-soluble and/or organize at interfaces between a fluorous phase and a non-fluorous phase. In some embodiments, emulsions or films are provided comprising a polymer. The polymers, emulsions, and films can be used in many applications, including for determining, treating, and/or imaging a condition and/or disease in a subject. The polymer may also be incorporated into various optoelectronic device such as photovoltaic cells, organic light-emitting diodes, organic field effect transistors, or the like. In some embodiments, the polymers comprise pi-conjugated backbones, and in some cases, are highly emissive.

  16. Thermoacoustic refrigerators and engines comprising cascading stirling thermodynamic units

    Energy Technology Data Exchange (ETDEWEB)

    Backhaus, Scott; Swift, Greg

    2013-06-25

    The present invention includes a thermoacoustic assembly and method for improved efficiency. The assembly has a first stage Stirling thermal unit comprising a main ambient heat exchanger, a regenerator and at least one additional heat exchanger. The first stage Stirling thermal unit is serially coupled to a first end of a quarter wavelength long coupling tube. A second stage Stirling thermal unit comprising a main ambient heat exchanger, a regenerator, and at least one additional heat exchanger, is serially coupled to a second end of the quarter wavelength long coupling tube.

  17. Thermoacoustic refrigerators and engines comprising cascading stirling thermodynamic units

    Science.gov (United States)

    Backhaus, Scott; Swift, Greg

    2013-06-25

    The present invention includes a thermoacoustic assembly and method for improved efficiency. The assembly has a first stage Stirling thermal unit comprising a main ambient heat exchanger, a regenerator and at least one additional heat exchanger. The first stage Stirling thermal unit is serially coupled to a first end of a quarter wavelength long coupling tube. A second stage Stirling thermal unit comprising a main ambient heat exchanger, a regenerator, and at least one additional heat exchanger, is serially coupled to a second end of the quarter wavelength long coupling tube.

  18. Instrumentation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — Provides instrumentation support for flight tests of prototype weapons systems using a vast array of airborne sensors, transducers, signal conditioning and encoding...

  19. DC-to-DC converter comprising a reconfigurable capacitor unit

    NARCIS (Netherlands)

    Klootwijk, J.H.; Bergveld, H.J.; Roozeboom, F.; Reefman, D.; Ruigrok, J.

    2013-01-01

    The present invention relates to a configurable trench multi-capacitor device comprising a trench in a semiconductor substrate. The trench has a lateral extension exceeding 10 micrometer and a trench filling includes a number of at least four electrically conductive capacitor-electrode layers. A

  20. Method of treating ammonia-comprising waste water

    NARCIS (Netherlands)

    Van Loosdrecht, M.C.M.; Jetten, M.S.M.

    1998-01-01

    The invention relates to a method of treating ammonia-comprising waste water in which the bicarbonate ion is the counter ion of the ammonium ion present in the waste water. According to the invention half the ammonium is converted into nitrite, yielding an ammonia- and nitrite-containing solution, a

  1. Non-cementitious compositions comprising vaterite and methods thereof

    Energy Technology Data Exchange (ETDEWEB)

    Devenney, Martin; Fernandez, Miguel; Morgan, Samuel O.

    2015-09-15

    Non-cementitious compositions and products are provided. The compositions of the invention include a carbonate additive comprising vaterite such as reactive vaterite. Additional aspects of the invention include methods of making and using the non-cementitious compositions and products.

  2. Hetdex: Virus Instrument

    Science.gov (United States)

    Lee, Hanshin; Hill, G. J.; DePoy, D. L.; Tuttle, S.; Marshall, J. L.; Vattiat, B. L.; Prochaska, T.; Chonis, T. S.; Allen, R.; HETDEX Collaboration

    2012-01-01

    The Visible Integral-field-unit Replicable Unit Spectrograph (VIRUS) instrument is made up of 150+ individually compact and identical spectrographs, each fed by a fiber integral-field unit. The instrument provides integral field spectroscopy at wavelengths between 350nm and 550nm of over 33,600 spatial elements per observation, each 1.8 sq. arcsec on the sky, at R 700. The instrument will be fed by a new wide-field corrector (WFC) of the Hobby-Eberly Telescope (HET) with increased science field of view as large as 22arcmin diameter and telescope aperture of 10m. This will enable the HETDEX, a large area blind survey of Lyman-alpha emitting galaxies at redshift z VIRUS instrument construction is summarized.

  3. Surveys: an introduction.

    Science.gov (United States)

    Rubenfeld, Gordon D

    2004-10-01

    Surveys are a valuable research tool for studying the knowledge, attitudes, and behavior of a study population. This article explores quantitative analyses of written questionnaires as instruments for survey research. Obtaining accurate and precise information from a survey requires minimizing the possibility of bias from inappropriate sampling or a flawed survey instrument, and this article describes strategies to minimize sampling bias by increasing response rates, comparing responders to nonresponders, and identifying the appropriate sampling population. It is crucial that the survey instrument be valid, meaning that it actually measures what the investigator intends it to measure. In developing a valid survey instrument, it can be useful to adapt survey instruments that were developed by other researchers and to conduct extensive pilot-testing of your survey instrument.

  4. Reading Attitudes of Middle School Students: Results of a U.S. Survey

    Science.gov (United States)

    McKenna, Michael C.; Conradi, Kristin; Lawrence, Camille; Jang, Bong Gee; Meyer, J. Patrick

    2012-01-01

    To examine the current state of reading attitudes among middle school students in the United States, a survey was developed and administered to 4,491 students in 23 states plus the District of Columbia. The instrument comprised four subscales measuring attitudes toward: recreational reading in print settings, recreational reading in digital…

  5. Reading Attitudes of Middle School Students: Results of a U.S. Survey

    Science.gov (United States)

    McKenna, Michael C.; Conradi, Kristin; Lawrence, Camille; Jang, Bong Gee; Meyer, J. Patrick

    2012-01-01

    To examine the current state of reading attitudes among middle school students in the United States, a survey was developed and administered to 4,491 students in 23 states plus the District of Columbia. The instrument comprised four subscales measuring attitudes toward: recreational reading in print settings, recreational reading in digital…

  6. Islamic Astronomical Instruments and Observatories

    Science.gov (United States)

    Heidarzadeh, Tofigh

    This chapter is a brief survey of astronomical instruments being used and developed in Islamic territories from the eighth to the fifteenth centuries as well as a concise account of major observatories and observational programs in this period.

  7. Recyclable organic solar cells on substrates comprising cellulose nanocrystals (CNC)

    Energy Technology Data Exchange (ETDEWEB)

    Kippelen, Bernard; Fuentes-Hernandez, Canek; Zhou, Yinhua; Moon, Robert; Youngblood, Jeffrey P

    2015-12-01

    Recyclable organic solar cells are disclosed herein. Systems and methods are further disclosed for producing, improving performance, and for recycling the solar cells. In certain example embodiments, the recyclable organic solar cells disclosed herein include: a first electrode; a second electrode; a photoactive layer disposed between the first electrode and the second electrode; an interlayer comprising a Lewis basic oligomer or polymer disposed between the photoactive layer and at least a portion of the first electrode or the second electrode; and a substrate disposed adjacent to the first electrode or the second electrode. The interlayer reduces the work function associated with the first or second electrode. In certain example embodiments, the substrate comprises cellulose nanocrystals that can be recycled. In certain example embodiments, one or more of the first electrode, the photoactive layer, and the second electrode may be applied by a film transfer lamination method.

  8. A Survey of Florida High School Instrumental Music Programs: Rationale for the Inclusion of Jazz Ensemble Experience in Music Teacher Training

    Science.gov (United States)

    Hinkle, Jonathan R.

    2011-01-01

    During the past 60 years, jazz music has slowly become recognized as a genre worthy of study in high school music programs throughout the United States. Only a few researchers have analyzed large samples of jazz-related instruction in instrumental music programs, and of these studies no data were collected to investigate the inclusion of jazz in…

  9. A Survey of Florida High School Instrumental Music Programs: Rationale for the Inclusion of Jazz Ensemble Experience in Music Teacher Training

    Science.gov (United States)

    Hinkle, Jonathan R.

    2011-01-01

    During the past 60 years, jazz music has slowly become recognized as a genre worthy of study in high school music programs throughout the United States. Only a few researchers have analyzed large samples of jazz-related instruction in instrumental music programs, and of these studies no data were collected to investigate the inclusion of jazz in…

  10. The Student Human Papillomavirus Survey: Nurse-Led Instrument Development and Psychometric Testing to Increase Human Papillomavirus Vaccine Series Completion in Young Adults.

    Science.gov (United States)

    Thomas, Tami; Dalmida, Safyia; Higgins, Melinda

    2016-01-01

    The Student Human Papillomavirus Survey (SHPVS) was developed to examine students' perceived benefits or barriers to human papillomavirus (HPV) vaccination. Survey development included (a) 2-phase integrative literature reviews; (b) draft of survey items based on the literature; (c) critique of survey items by young adults, nursing and psychology faculty, and health care providers; and (d) pilot testing. The psychometric properties of the SHPVS were evaluated using classical item analysis and exploratory factor analysis (EFA) among a sample of 527 university students' ages 18-24 years. The estimated Cronbach's alpha for the SHPVS is .74. The SHPVS is a measure of young adults HPV perceived vulnerability, perceived severity, perceived barriers, and perceived benefits of HPV vaccination.

  11. Luminescence Instrumentation

    DEFF Research Database (Denmark)

    Jain, Mayank; Bøtter-Jensen, Lars

    2014-01-01

    This chapter gives an introduction to instrumentation for stimulated luminescence studies, with special focus on luminescence dating using the natural dosimeters, quartz and feldspars. The chapter covers basic concepts in luminescence detection, and thermal and optical stimulation, and reference...

  12. Electrochemical cell comprising stable hydride-forming material

    Energy Technology Data Exchange (ETDEWEB)

    Willems, J. J. G. S. A.; van Beek, J. R. G. C. M.; Buschow, K. H. J.

    1984-12-11

    An electrochemical cell having a negative electrode comprising a compound derived from LaNi/sub 5/, in which La is optionally substituted by a plateau pressure-increasing element and in which Ni is substituted entirely or partly by a plateau pressure-reducing element, for example, Co and/or Cu, with the object of considerably reducing volume steps and hence crack formation of the intermetallic compound during charging and discharging. Moreover, the corrosion of the intermetallic compound is counteracted by adding small quantities of Al, Cr and/or Si, Which metals enhance the formation of a protecting oxide layer.

  13. Multilayer Electroactive Polymer Composite Material Comprising Carbon Nanotubes

    Science.gov (United States)

    Ounaies, Zoubeida (Inventor); Park, Cheol (Inventor); Harrison, Joycelyn S. (Inventor); Holloway, Nancy M. (Inventor); Draughon, Gregory K. (Inventor)

    2009-01-01

    An electroactive material comprises multiple layers of electroactive composite with each layer having unique dielectric, electrical and mechanical properties that define an electromechanical operation thereof when affected by an external stimulus. For example, each layer can be (i) a 2-phase composite made from a polymer with polarizable moieties and an effective amount of carbon nanotubes incorporated in the polymer for a predetermined electromechanical operation, or (ii) a 3-phase composite having the elements of the 2-phase composite and further including a third component of micro-sized to nano-sized particles of an electroactive ceramic incorporated in the polymer matrix.

  14. Photovoltaic device comprising compositionally graded intrinsic photoactive layer

    Science.gov (United States)

    Hoffbauer, Mark A; Williamson, Todd L

    2013-04-30

    Photovoltaic devices and methods of making photovoltaic devices comprising at least one compositionally graded photoactive layer, said method comprising providing a substrate; growing onto the substrate a uniform intrinsic photoactive layer having one surface disposed upon the substrate and an opposing second surface, said intrinsic photoactive layer consisting essentially of In.sub.1-xA.sub.xN,; wherein: i. 0.ltoreq.x.ltoreq.1; ii. A is gallium, aluminum, or combinations thereof; and iii. x is at least 0 on one surface of the intrinsic photoactive layer and is compositionally graded throughout the layer to reach a value of 1 or less on the opposing second surface of the layer; wherein said intrinsic photoactive layer is isothermally grown by means of energetic neutral atom beam lithography and epitaxy at a temperature of 600.degree. C. or less using neutral nitrogen atoms having a kinetic energy of from about 1.0 eV to about 5.0 eV, and wherein the intrinsic photoactive layer is grown at a rate of from about 5 nm/min to about 100 nm/min.

  15. Study Project Comprising Two Surveys on Behalf of the National Association of State Boating Law Administrators.

    Science.gov (United States)

    1975-06-01

    units been involved in a search for persons thought to be lost in the water? Boat Swimmer Hunter-Fisherman Aircraft Total 11 Would staff of your SAR...Governors Island. Our search plan coincides with standard procedures (i.e.) expanded search, etc. 5. Occurrences involving swimmers and surfers have...0 :D 4Jf 10 OU 4 PC to 41N~ 0~ 0 lue ~ --4 0 0 m4O0 ~ 4~ Z) ts Z 0 - - imt < U- 4 ") 4H 0 u0 u i 69 CD 00 o 0000 0 0 0 S0cJ N Oa O 0 %D %.0~o o..-r O

  16. Instrumented SSH

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Scott; Campbell, Scott

    2009-05-27

    NERSC recently undertook a project to access and analyze Secure Shell (SSH) related data. This includes authentication data such as user names and key fingerprints, interactive session data such as keystrokes and responses, and information about noninteractive sessions such as commands executed and files transferred. Historically, this data has been inaccessible with traditional network monitoring techniques, but with a modification to the SSH daemon, this data can be passed directly to intrusion detection systems for analysis. The instrumented version of SSH is now running on all NERSC production systems. This paper describes the project, details about how SSH was instrumented, and the initial results of putting this in production.

  17. Dynamical Configurations of Celestial Systems Comprised of Multiple Irregular Bodies

    CERN Document Server

    Jiang, Yu; Baoyin, Hexi; Li, Junfeng

    2016-01-01

    This manuscript considers the main features of the nonlinear dynamics of multiple irregular celestial body systems. The gravitational potential, static electric potential, and magnetic potential are considered. Based on the three established potentials, we show that three conservative values exist for this system, including a Jacobi integral. The equilibrium conditions for the system are derived and their stability analyzed. The equilibrium conditions of a celestial system comprised of n irregular bodies are reduced to 12n minus 9 equations. The dynamical results are applied to simulate the motion of multiple-asteroid systems. The simulation is useful for the study of the stability of multiple irregular celestial body systems and for the design of spacecraft orbits to triple asteroid systems discovered in the solar system. The dynamical configurations of the five triple-asteroid systems 45 Eugenia, 87 Sylvia, 93 Minerva, 216 Kleopatra, and 136617 1994CC, and the six-body system 134340 Pluto are calculated and...

  18. Solid polymer electrolyte composite membrane comprising laser micromachined porous support

    Science.gov (United States)

    Liu, Han [Waltham, MA; LaConti, Anthony B [Lynnfield, MA; Mittelsteadt, Cortney K [Natick, MA; McCallum, Thomas J [Ashland, MA

    2011-01-11

    A solid polymer electrolyte composite membrane and method of manufacturing the same. According to one embodiment, the composite membrane comprises a rigid, non-electrically-conducting support, the support preferably being a sheet of polyimide having a thickness of about 7.5 to 15 microns. The support has a plurality of cylindrical pores extending perpendicularly between opposing top and bottom surfaces of the support. The pores, which preferably have a diameter of about 5 microns, are made by laser micromachining and preferably are arranged in a defined pattern, for example, with fewer pores located in areas of high membrane stress and more pores located in areas of low membrane stress. The pores are filled with a first solid polymer electrolyte, such as a perfluorosulfonic acid (PFSA) polymer. A second solid polymer electrolyte, which may be the same as or different than the first solid polymer electrolyte, may be deposited over the top and/or bottom of the first solid polymer electrolyte.

  19. Complete Recycling of Composite Material Comprising Polybutylene Terephthalate and Copper

    Directory of Open Access Journals (Sweden)

    Fabian Knappich

    2017-06-01

    Full Text Available Composite materials comprising plastic and metal parts generate a large amount of waste containing valuable components that are difficult to separate and recycle. We therefore developed an economical solvent-based process for the recovery of costly manufactured composite materials comprising several copper panels over-moulded with a polymeric matrix of polybutylene terephthalate (PBT. We applied the CreaSolv® Process, which uses proprietary formulations with a low risk to user and environment, in order to dissolve the polymer and retain the inert copper. After separating the metal from the solution, solvent recovery was achieved by means of vacuum distillation and melt degassing extrusion. The recovered solvent was collected and recycled while maintaining its original properties. We tested two candidate solvents with PBT, measuring their impact on the molecular weight (Mw and polydispersity of the polymer at different residence times and dissolution temperatures. We found that increasing the temperature-time-load had a negative effect on the Mw. Both solvents we tested were able to dissolve the polymeric matrix within 30 min and with moderate energy consumption. Furthermore, we found that the exclusion of oxygen during dissolution significantly increases the quality of the recovered polymer and metal. We transferred the process from the laboratory scale to the small-technical scale and produced material for large analytical and mechanical quality evaluation, revealing no decline in the polymer quality by blending with new plastic. The recovered copper met virgin material properties. Therefore, both components of the original composite material have been recovered in a form suitable for reuse.

  20. [Evaluation of the level of dependency of persons placed in establishments for chronic patients. Development of a survey instrument and studies of validity, pertinence and performance].

    Science.gov (United States)

    Lehmann, P; Martin, J

    1984-01-01

    With the aim to achieve a more equitable budgetary allocation to nursing homes, an instrument for the evaluation of the patients' dependency has been developed and tested in 55 institutions, for a total of about 23000 observations. Statistical analyses show that the internal validity of the gathered data is quite good. The tool criteria are judged relevant by experts, and the tool performance is adequate: its use should permit the constitution of groups (clustering) of nursing homes homogeneous from the point of view of their nursing care load.

  1. Validation of the Care-Related Quality of Life Instrument in different study settings: findings from The Older Persons and Informal Caregivers Survey Minimum DataSet (TOPICS-MDS).

    Science.gov (United States)

    Lutomski, J E; van Exel, N J A; Kempen, G I J M; Moll van Charante, E P; den Elzen, W P J; Jansen, A P D; Krabbe, P F M; Steunenberg, B; Steyerberg, E W; Olde Rikkert, M G M; Melis, R J F

    2015-05-01

    Validity is a contextual aspect of a scale which may differ across sample populations and study protocols. The objective of our study was to validate the Care-Related Quality of Life Instrument (CarerQol) across two different study design features, sampling framework (general population vs. different care settings) and survey mode (interview vs. written questionnaire). Data were extracted from The Older Persons and Informal Caregivers Minimum DataSet (TOPICS-MDS, www.topics-mds.eu ), a pooled public-access data set with information on >3,000 informal caregivers throughout the Netherlands. Meta-correlations and linear mixed models between the CarerQol's seven dimensions (CarerQol-7D) and caregiver's level of happiness (CarerQol-VAS) and self-rated burden (SRB) were performed. The CarerQol-7D dimensions were correlated to the CarerQol-VAS and SRB in the pooled data set and the subgroups. The strength of correlations between CarerQol-7D dimensions and SRB was weaker among caregivers who were interviewed versus those who completed a written questionnaire. The directionality of associations between the CarerQol-VAS, SRB and the CarerQol-7D dimensions in the multivariate model supported the construct validity of the CarerQol in the pooled population. Significant interaction terms were observed in several dimensions of the CarerQol-7D across sampling frame and survey mode, suggesting meaningful differences in reporting levels. Although good scientific practice emphasises the importance of re-evaluating instrument properties in individual research studies, our findings support the validity and applicability of the CarerQol instrument in a variety of settings. Due to minor differential reporting, pooling CarerQol data collected using mixed administration modes should be interpreted with caution; for TOPICS-MDS, meta-analytic techniques may be warranted.

  2. Active instruments

    DEFF Research Database (Denmark)

    Lim, Miguel Antonio; Ørberg, Jakob Williams

    2017-01-01

    ) show the dynamic nature of policy processes, and (3) consider the search for policy reference points among the different actors. We present rankers in motion, policies in motion, and finally the complex nature of the ranking device that needs to be both a relevant and malleable policy instrument...

  3. A test instrument for palliative care.

    NARCIS (Netherlands)

    Adriaansen, M.J.M.; Achterberg, T. van

    2004-01-01

    This article describes a methodological study concerning the development of a test instrument that can be used for measuring the effects of a course in palliative care on registered nurses and licensed practical nurses. This test instrument is comprised of two parts: an expertise and insight test an

  4. A test instrument for palliative care.

    NARCIS (Netherlands)

    Adriaansen, M.J.M.; Achterberg, T. van

    2004-01-01

    This article describes a methodological study concerning the development of a test instrument that can be used for measuring the effects of a course in palliative care on registered nurses and licensed practical nurses. This test instrument is comprised of two parts: an expertise and insight test

  5. Parental Human Papillomavirus Vaccine Survey (PHPVS): nurse-led instrument development and psychometric testing for use in research and primary care screening.

    Science.gov (United States)

    Thomas, Tami Lynn; Strickland, Ora L; DiClemente, Ralph; Higgins, Melinda; Williams, Bryan; Hickey, Kathleen

    2013-01-01

    Human papillomavirus (HPV) vaccine was approved for girls aged 9-24 years in 2006 to prevent HPV infection and cervical cancer. The Parental Human Papillomavirus Survey (PHPVS) was framed on theoretical constructs of the health belief model (HBM) and developed to survey parents regarding their HPV knowledge, attitudes, and intent to vaccinate. We evaluated the psychometric properties of the PHPVS using classical item analysis and exploratory factor analysis (EFA) among a sample of 200 parents/caregivers. The EFA yielded a 4-factor unidimensional model that explained between 62% and 68% of the total variance depending on the extraction method used. The estimated Cronbach's alpha for the PHPVS was .96. The PHPVS is a reliable measure of HPV knowledge, attitudes, and intent to vaccinate.

  6. STREPTOMYCES SPECIES COMPRISING THE BLUE-SPORE SERIES.

    Science.gov (United States)

    TREJO, W H; BENNETT, R E

    1963-03-01

    Trejo, W. H. (Squibb Institute for Medical Research, New Brunswick, N.J.) and R. E. Bennett. Streptomyces species comprising the blue-spore series. J. Bacteriol. 85:676-690. 1963.-The objective of this study was to define and delimit the streptomycetes of the blue-spored (Viridochromogenes) series. The series, as defined in this study, includes 11 blue and blue-green species. The green-spored species were excluded on the basis of morphology as well as color. It was proposed that NRRL B-1511 be designated as the neotype strain of Streptomyces viridochromogenes (Krainsky) Waksman and Henrici, and that IMRU 3761 be designated as the neotype for Streptomyces cyaneus (Krassilnikov) Waksman. Evidence was presented to show that physiological criteria cannot be used to differentiate these organisms below the series level. The major characteristics of the Viridochromogenes series are blue to blue-green spores borne in spirals, and chromogenicity (melanin-positive). Reverse color and spore morphology provide a basis for separation below the series level.

  7. Solid polymer electrolyte composite membrane comprising plasma etched porous support

    Science.gov (United States)

    Liu, Han; LaConti, Anthony B.

    2010-10-05

    A solid polymer electrolyte composite membrane and method of manufacturing the same. According to one embodiment, the composite membrane comprises a rigid, non-electrically-conducting support, the support preferably being a sheet of polyimide having a thickness of about 7.5 to 15 microns. The support has a plurality of cylindrical pores extending perpendicularly between opposing top and bottom surfaces of the support. The pores, which preferably have a diameter of about 0.1 to 5 microns, are made by plasma etching and preferably are arranged in a defined pattern, for example, with fewer pores located in areas of high membrane stress and more pores located in areas of low membrane stress. The pores are filled with a first solid polymer electrolyte, such as a perfluorosulfonic acid (PFSA) polymer. A second solid polymer electrolyte, which may be the same as or different than the first solid polymer electrolyte, may be deposited over the top and/or bottom of the first solid polymer electrolyte.

  8. The rat pineal gland comprises an endocannabinoid system.

    Science.gov (United States)

    Koch, Marco; Habazettl, Iris; Dehghani, Faramarz; Korf, Horst-Werner

    2008-11-01

    In the mammalian pineal gland, the rhythm in melatonin biosynthesis depends on the norepinephrine (NE)-driven regulation of arylalkylamine N-acetyltransferase (AANAT), the penultimate enzyme of melatonin biosynthesis. A recent study showed that phytocannabinoids like tetrahydrocannabinol reduce AANAT activity and attenuate NE-induced melatonin biosynthesis in rat pineal glands, raising the possibility that an endocannabinoid system is present in the pineal gland. To test this hypothesis, we analyzed cannabinoid (CB) receptors and specific enzymes for endocannabinoid biosynthesis or catabolism in rat pineal glands and cultured pinealocytes. Immunohistochemical and immunoblot analyses revealed the presence of CB1 and CB2 receptor proteins, of N-acyl phosphatidyl ethanolamine hydrolyzing phospholipase D (NAPE-PLD), an enzyme catalyzing endocannabinoid biosynthesis and of fatty acid amide hydrolase (FAAH), an endocannabinoid catabolizing enzyme, in pinealocytes, and in pineal sympathetic nerve fibers identified by double immunofluorescence with an antibody against tyrosine hydroxylase. The immunosignals for the CB2 receptor, NAPE-PLD, and FAAH found in pinealocytes did not vary under a 12 hr light:12 hr dark cycle. The CB1 receptor immunoreaction in pinealocytes was significantly reduced at the end of the light phase [zeitgeber time (ZT) 12]. The immunosignal for NAPE-PLD found in pineal sympathetic nerve fibers was reduced in the middle of the dark phase (ZT 18). Stimulation of cultured pinealocytes with NE affected neither the subcellular distribution nor the intensity of the immunosignals for the investigated CB receptors and enzymes. In summary, the pineal gland comprises indispensable compounds of the endocannabinoid system indicating that endocannabinoids may be involved in the control of pineal physiology.

  9. Pancreatitis Quality of Life Instrument: Development of a new instrument

    Directory of Open Access Journals (Sweden)

    Wahid Wassef

    2014-02-01

    Full Text Available Objectives: The goal of this project was to develop the first disease-specific instrument for the evaluation of quality of life in chronic pancreatitis. Methods: Focus groups and interview sessions were conducted, with chronic pancreatitis patients, to identify items felt to impact quality of life which were subsequently formatted into a paper-and-pencil instrument. This instrument was used to conduct an online survey by an expert panel of pancreatologists to evaluate its content validity. Finally, the modified instrument was presented to patients during precognitive testing interviews to evaluate its clarity and appropriateness. Results: In total, 10 patients were enrolled in the focus groups and interview sessions where they identified 50 items. Once redundant items were removed, the 40 remaining items were made into a paper-and-pencil instrument referred to as the Pancreatitis Quality of Life Instrument. Through the processes of content validation and precognitive testing, the number of items in the instrument was reduced to 24. Conclusions: This marks the development of the first disease-specific instrument to evaluate quality of life in chronic pancreatitis. It includes unique features not found in generic instruments (economic factors, stigma, and spiritual factors. Although this marks a giant step forward, psychometric evaluation is still needed prior to its clinical use.

  10. Coseismic Deformations Associated with the M=7.2, April 04, 2010, El Mayor-Cucapah Earthquake, Observed from Leveling Survey, Geotechnical Instruments and Water Level Changes in the Mexicali Valley

    Science.gov (United States)

    Glowacka, E.; Robles, B.; Vázquez, R.; Sarychikhina, O.; Suárez-Vidal, F.; Ramirez, J.; Nava Pichardo, F. A.; Farfan, F.; Diaz de Cossio, G.

    2010-12-01

    A first order, second class leveling survey in the Mexicali Valley had been just finished in February 2010, for a project carried out by CICESE (Center for Scientific Research and Higher Education of Ensenada), IMTA (Mexican Institute of Water Technology) and CONAGUA (National Water Comission). Immediately after the M=7.2 earthquake the survey was repeated along 240 km of the profiles in the area of the Cerro Prieto pull-apart basin. The leveling started at the LN00 GPS monument in La Puerta. Overall, an uplift of about 30 cm towards the NE, along the 38 km line, in direction SW-NE is observed with larger gradient to the South of the area. Three subsidence bowls differ from this general pattern. One, south from Ejido Saltillo, with the relative subsidence of 19 cm (considering the displacement at LN00 as zero subsidence), probably reflects subsidence of the Saltillo-Guerrero graben; the second, with a subsidence of 23 cm, is situated south from Ejido Nuevo Leon and can be related to the subsidence triggered by the earthquake in the production area of Cerro Prieto IV. For the third one, with relative depth of 36 cm, situated close to Zacamoto, the southeastern limit cannot be determined, so only a comparison with other methods can explain the origin of this anomaly. All the subsidence bowls are associated with liquefaction observed in the area, with more liquefaction observed close to Zacamoto. Since 1996, CICESE has been operating a network of geotechnical instruments (REDECVAM) for continuous recording of deformation related to tectonic (seismic and interseismic) phenomena, as well as anthropogenic deformation caused by the deep fluid extraction at the Cerro Prieto Geothermal Field. The instruments are installed along the faults which limit the Cerro Prieto pull-apart basin at a distance from 8 to 15 km from the epicenter. Coseismic step-like groundwater level changes ranging from 0.4 to 5.0 meters were recorded at 4 wells in the Cerro Prieto Pull apart

  11. Policy Dialogue and Engagement between Non-Governmental Organizations and Government: A Survey of Processes and Instruments of Canadian Policy Workers

    Directory of Open Access Journals (Sweden)

    Bryan Mitchell Evans

    2013-07-01

    Full Text Available Various analysts have raised concerns respecting declining research, evaluation and analytical capacities within public services. Typically, the decline is attributed to reforms associated with neoliberal restructuring of the state and its concomitant managerial expression in New Public Management (NPM.  This has given rise to a conceptual shift now commonly captured as a movement from ‘government’ to ‘governance’. Policy advising from a new governance perspective entails an image of a more distributed policy advisory system where a plurality of actors, including non-state actors, engages with government in deliberating policy interventions to address collective problems.The original research presented here suggests that those responsible for policy work across four policy communities in the three Canadian provinces surveyed differ in terms of their capacities, depth of commitment to a specific policy file/field, roles and functions, as well as perceptions of the policy work that they undertake. Over the past several years, a number of primarily quantitative analyses examining the processes, tools and perspectives of Canadian federal and provincial government policy analysts have been published.  Consequently, a significant knowledge-base has been acquired respecting what government policy analysts do and their attitudes toward their work but very little is known about external interactions with non-governmental organizations (NGOs.

  12. Optical Instruments

    Science.gov (United States)

    1990-01-01

    Precision Lapping and Optical Co. has developed a wide variety of hollow retroreflector systems for applications involving the entire optical spectrum; they are, according to company literature, cheaper, more accurate, lighter and capable of greater size than solid prisms. Precision Lapping's major customers are aerospace and defense companies, government organizations, R&D and commercial instrument companies. For example, Precision Lapping supplies hollow retroreflectors for the laser fire control system of the Army's Abrams tank, and retroreflectors have been and are being used in a number of space tests relative to the Air Force's Strategic Defense Initiative research program. An example of a customer/user is Chesapeake Laser Systems, producer of the Laser Tracker System CMS-2000, which has applications in SDI research and industrial robotics. Another customer is MDA Scientific, Inc., manufacturer of a line of toxic gas detection systems used to monitor hazardous gases present in oil fields, refineries, offshore platforms, chemical plants, waste storage sites and other locations where gases are released into the environment.

  13. CARMENES instrument overview

    Science.gov (United States)

    Quirrenbach, A.; Amado, P. J.; Caballero, J. A.; Mundt, R.; Reiners, A.; Ribas, I.; Seifert, W.; Abril, M.; Aceituno, J.; Alonso-Floriano, F. J.; Ammler-von Eiff, M.; Antona Jiménez, R.; Anwand-Heerwart, H.; Azzaro, M.; Bauer, F.; Barrado, D.; Becerril, S.; Béjar, V. J. S.; Benítez, D.; Berdiñas, Z. M.; Cárdenas, M. C.; Casal, E.; Claret, A.; Colomé, J.; Cortés-Contreras, M.; Czesla, S.; Doellinger, M.; Dreizler, S.; Feiz, C.; Fernández, M.; Galadí, D.; Gálvez-Ortiz, M. C.; García-Piquer, A.; García-Vargas, M. L.; Garrido, R.; Gesa, L.; Gómez Galera, V.; González Álvarez, E.; González Hernández, J. I.; Grözinger, U.; Guàrdia, J.; Guenther, E. W.; de Guindos, E.; Gutiérrez-Soto, J.; Hagen, H.-J.; Hatzes, A. P.; Hauschildt, P. H.; Helmling, J.; Henning, T.; Hermann, D.; Hernández Castaño, L.; Herrero, E.; Hidalgo, D.; Holgado, G.; Huber, A.; Huber, K. F.; Jeffers, S.; Joergens, V.; de Juan, E.; Kehr, M.; Klein, R.; Kürster, M.; Lamert, A.; Lalitha, S.; Laun, W.; Lemke, U.; Lenzen, R.; López del Fresno, Mauro; López Martí, B.; López-Santiago, J.; Mall, U.; Mandel, H.; Martín, E. L.; Martín-Ruiz, S.; Martínez-Rodríguez, H.; Marvin, C. J.; Mathar, R. J.; Mirabet, E.; Montes, D.; Morales Muñoz, R.; Moya, A.; Naranjo, V.; Ofir, A.; Oreiro, R.; Pallé, E.; Panduro, J.; Passegger, V.-M.; Pérez-Calpena, A.; Pérez Medialdea, D.; Perger, M.; Pluto, M.; Ramón, A.; Rebolo, R.; Redondo, P.; Reffert, S.; Reinhardt, S.; Rhode, P.; Rix, H.-W.; Rodler, F.; Rodríguez, E.; Rodríguez-López, C.; Rodríguez-Pérez, E.; Rohloff, R.-R.; Rosich, A.; Sánchez-Blanco, E.; Sánchez Carrasco, M. A.; Sanz-Forcada, J.; Sarmiento, L. F.; Schäfer, S.; Schiller, J.; Schmidt, C.; Schmitt, J. H. M. M.; Solano, E.; Stahl, O.; Storz, C.; Stürmer, J.; Suárez, J. C.; Ulbrich, R. G.; Veredas, G.; Wagner, K.; Winkler, J.; Zapatero Osorio, M. R.; Zechmeister, M.; Abellán de Paco, F. J.; Anglada-Escudé, G.; del Burgo, C.; Klutsch, A.; Lizon, J. L.; López-Morales, M.; Morales, J. C.; Perryman, M. A. C.; Tulloch, S. M.; Xu, W.

    2014-07-01

    This paper gives an overview of the CARMENES instrument and of the survey that will be carried out with it during the first years of operation. CARMENES (Calar Alto high-Resolution search for M dwarfs with Exoearths with Near-infrared and optical Echelle Spectrographs) is a next-generation radial-velocity instrument under construction for the 3.5m telescope at the Calar Alto Observatory by a consortium of eleven Spanish and German institutions. The scientific goal of the project is conducting a 600-night exoplanet survey targeting ~ 300 M dwarfs with the completed instrument. The CARMENES instrument consists of two separate echelle spectrographs covering the wavelength range from 0.55 to 1.7 μm at a spectral resolution of R = 82,000, fed by fibers from the Cassegrain focus of the telescope. The spectrographs are housed in vacuum tanks providing the temperature-stabilized environments necessary to enable a 1 m/s radial velocity precision employing a simultaneous calibration with an emission-line lamp or with a Fabry-Perot etalon. For mid-M to late-M spectral types, the wavelength range around 1.0 μm (Y band) is the most important wavelength region for radial velocity work. Therefore, the efficiency of CARMENES has been optimized in this range. The CARMENES instrument consists of two spectrographs, one equipped with a 4k x 4k pixel CCD for the range 0.55 - 1.05 μm, and one with two 2k x 2k pixel HgCdTe detectors for the range from 0.95 - 1.7μm. Each spectrograph will be coupled to the 3.5m telescope with two optical fibers, one for the target, and one for calibration light. The front end contains a dichroic beam splitter and an atmospheric dispersion corrector, to feed the light into the fibers leading to the spectrographs. Guiding is performed with a separate camera; on-axis as well as off-axis guiding modes are implemented. Fibers with octagonal cross-section are employed to ensure good stability of the output in the presence of residual guiding errors. The

  14. The integration of similar clinical research data collection instruments.

    Science.gov (United States)

    Cohen, Dorothy B; Frawley, Sandra J; Shifman, Mark A; Miller, Perry L; Brandt, Cynthia

    2003-01-01

    We devised an algorithm for integrating similar clinical research data collection instruments to create a common measurement instrument. We tested this algorithm using questions from several similar surveys. We encountered differing levels of granularity among questions and responses across surveys resulting in either the loss of granularity or data. This algorithm may make survey integration more systematic and efficient.

  15. The wide field imager instrument for Athena

    Science.gov (United States)

    Meidinger, Norbert; Eder, Josef; Eraerds, Tanja; Nandra, Kirpal; Pietschner, Daniel; Plattner, Markus; Rau, Arne; Strecker, Rafael

    2016-07-01

    The WFI (Wide Field Imager) instrument is planned to be one of two complementary focal plane cameras on ESA's next X-ray observatory Athena. It combines unprecedented survey power through its large field of view of 40 amin x 40 amin together with excellent count rate capability (>= 1 Crab). The energy resolution of the silicon sensor is state-of-the-art in the energy band of interest from 0.2 keV to 15 keV, e.g. the full width at half maximum of a line at 7 keV will be pixel sensors with a pixel size of 130 μm x 130 μm well suited to the on-axis angular resolution of 5 arcsec half energy width (HEW) of the mirror system. Each DEPFET pixel is a combined sensor-amplifier structure with a MOSFET integrated onto a fully depleted 450 μm thick silicon bulk. Two detectors are planned for the WFI instrument: A large-area detector comprising four sensors with a total of 1024 x 1024 pixels and a fast detector optimized for high count rate observations. This high count rate capable detector permits for bright point sources with an intensity of 1 Crab a throughput of more than 80% and a pile-up of less than 1%. The fast readout of the DEPFET pixel matrices is facilitated by an ASIC development, called VERITAS-2. Together with the Switcher-A, a control ASIC that allows for operation of the DEPFET in rolling shutter mode, these elements form the key components of the WFI detectors. The detectors are surrounded by a graded-Z shield, which has in particular the purpose to avoid fluorescence lines that would contribute to the instrument background. Together with ultra-thin coating of the sensor and particle identification by the detector itself, the particle induced background shall be minimized in order to achieve the scientific requirement of a total instrumental background value smaller than 5 x 10-3 cts/cm2/s/keV. Each detector has its dedicated detector electronics (DE) for supply and data acquisition. Due to the high frame rate in combination with the large pixel array

  16. Science with OCTOCAM: a new workhorse instrument proposed for Gemini

    Science.gov (United States)

    Thöne, Christina C.; de Ugarte Postigo, Antonio; van der Horst, Alexander; Roming, Pete

    2016-08-01

    OCTOCAM is an 8-channel VIS-IR (g to K-band) simultaneous imager and medium-resolution spectrograph proposed as new workhorse instrument for the 8m Gemini telescopes. It also offers additional observing modes of high time resolution, integral-field spectroscopy and spectropolarimetry, making it a very versatile instrument for many science cases in the 2020ies. A special focus of OCTOCAM will be the detection and follow-up of transient sources such as gamma-ray bursts, supernovae, magnetars, active galactic nuclei and yet to be discovered new objects, delivered by large-scale surveys like LSST available in the 2020ies. The diverse nature of transients will require the full range of OCTOCAM capabilities allowing more information in very short time about the source than with any other current instrument and adaptable almost in real time. Another main science topic will be to probe the high redshift Universe and the first stars for which OCTOCAM will be highly suited due to its wide wavelength coverage and high sensitivity. However, OCTOCAM is also suited for a large range of other science cases including transneptunian objects, exoplanets, stellar evolution and supermassive black holes. Our science team comprises more than 50 researchers reflecting the large interest of the Gemini community in the capabilities of OCTOCAM. We will highlight a few important science cases demonstrating the different capabilities of OCTOCAM and their need for the scientific community.

  17. Plane and geodetic surveying

    CERN Document Server

    Johnson, Aylmer

    2004-01-01

    Plane and Geodetic Surveying blends theory and practice, conventional techniques and GPS, to provide the ideal book for students of surveying.Detailed guidance is given on how and when the principle surveying instruments (theodolites, Total Stations, levels and GPS) should be used. Concepts and formulae needed to convert instrument readings into useful results are explained. Rigorous explanations of the theoretical aspects of surveying are given, while at the same time a wealth of useful advice about conducting a survey in practice is provided. An accompanying least squares adjustment program

  18. Optimising the effect of policy instruments

    DEFF Research Database (Denmark)

    Pedersen, Anders Branth; Nielsen, Helle Ørsted; Christensen, Tove

    2012-01-01

    as a case, this paper examines whether non-economic rationales may trump economic ones in farmer decisions, and, unlike previous research, we quantify how widespread non-economic values are compared to more economic values. Data derive from a survey (1164 responses) of Danish conventional farmers' decision...... to policy instruments; farmers who focus on yield indicate less responsiveness to economic policy instruments. The results imply that it is important to implement a broad array of policy instruments to match different farmer rationales....

  19. Instrumentation for Environmental Monitoring: Water, Volume 2.

    Science.gov (United States)

    California Univ., Berkeley. Lawrence Berkeley Lab.

    This volume is one of a series discussing instrumentation for environmental monitoring. Each volume contains an overview of the basic problems, comparisons among the basic methods of sensing and detection, and notes that summarize the characteristics of presently available instruments and techniques. The text of this survey discusses the…

  20. The 4MOST instrument concept overview

    NARCIS (Netherlands)

    Haynes, Roger; Barden, Samuel; de Jong, Roelof; Schnurr, Olivier; Bellido, Olga; Walcher, Jakob; Haynes, Dionne; Winkler, Roland; Bauer, Svend-Marian; Dionies, Frank; Saviauk, Allar; Chiappini, Cristina; Schwope, Axel; Brynnel, Joar; Steinmetz, Matthias; McMahon, Richard; Feltzing, Sofia; Francois, Patrick; Trager, Scott; Parry, Ian; Irwin, Mike; Walton, Nicholas; King, David; Sun, David; Gonzalez-Solares, Eduaro; Tosh, Ian; Dalton, Gavin; Middleton, Kevin; Bonifacio, Piercarlo; Jagourel, Pascal; Mignot, Shan; Cohen, Mathieu; Amans, Jean-Philippe; Royer, Frederic; Sartoretti, Paola; Pragt, Johan; Gerlofsma, Gerrit; Roelfsema, Ronald; Navarro, Ramon; Thimm, Guido; Seifert, Walter; Christlieb, Norbert; Mandel, Holger; Trifonov, Trifon; Xu, Wenli; Lang-Bardl, Florian; Muschielok, Bernard; Schlichter, Jörg; Hess, Hans-Joachim; Grupp, Frank; Boehringer, Hans; Boller, Thomas; Dwelly, Tom; Bender, Ralf; Rosati, Piero; Iwert, Olaf; Finger, Gert; Lizon L'Allemand, Jean-Louis; Saunders, Will; Sheinis, Andrew; Frost, Gabriella; Farrell, Tony; Waller, Lewis; Depagne, Eric; Laurent, Florence; Caillier, Patrick; Kosmalski, Johan; Richard, Johan; Bacon, Roland; Ansorge, Wolfgang

    2014-01-01

    The 4MOST[1] instrument is a concept for a wide-field, fibre-fed high multiplex spectroscopic instrument facility on the ESO VISTA telescope designed to perform a massive (initially >25x106 spectra in 5 years) combined all-sky public survey. The main science drivers are: Gaia follow up of chemo-dyna

  1. 浅谈新技术、新仪器在城市测绘中的应用%Discussion on New Technologies and New Instruments in Urban Surveying Applications

    Institute of Scientific and Technical Information of China (English)

    侯惠儒

    2012-01-01

    伴随着测绘科学技术的不断进步发展,城市测绘涌现出很多新技术、新仪器。GPS网络RTK技术、电子水准仪、三维全景采集车、数字城市、探地雷达、三维地下管线信息系统正是这些科技发展的前沿。介绍了这几种常见新技术、新仪器在城市测绘中的应用。%With the development of science and technology of surveying, lots of new technologies and new instruments come out. This paper introduces the following information--GPS network RTK technology, electronic level, 3D panoramic acquisition vehicle, digital city, Ground Penetrating Radar, 3D underground pipeline integrated management system, which are the forefront development of the science and technology.

  2. Development and psychometric testing of an instrument to measure safety climate perceptions in community pharmacy.

    Science.gov (United States)

    Newham, Rosemary; Bennie, Marion; Maxwell, David; Watson, Anne; de Wet, Carl; Bowie, Paul

    2014-12-01

    A positive and strong safety culture underpins effective learning from patient safety incidents in health care, including the community pharmacy (CP) setting. To build this culture, perceptions of safety climate must be measured with context-specific and reliable instruments. No pre-existing instruments were specifically designed or suitable for CP within Scotland. We therefore aimed to develop a psychometrically sound instrument to measure perceptions of safety climate within Scottish CPs. The first stage, development of a preliminary instrument, comprised three steps: (i) a literature review; (ii) focus group feedback; and (iii) content validation. The second stage, psychometric testing, consisted of three further steps: (iv) a pilot survey; (v) a survey of all CP staff within a single health board in NHS Scotland; and (vi) application of statistical methods, including principal components analysis and calculation of Cronbach's reliability coefficients, to derive the final instrument. The preliminary questionnaire was developed through a process of literature review and feedback. This questionnaire was completed by staff in 50 CPs from the 131 (38%) sampled. 250 completed questionnaires were suitable for analysis. Psychometric evaluation resulted in a 30-item instrument with five positively correlated safety climate factors: leadership, teamwork, safety systems, communication and working conditions. Reliability coefficients were satisfactory for the safety climate factors (α > 0.7) and overall (α = 0.93). The robust nature of the technical design and testing process has resulted in the development of an instrument with sufficient psychometric properties, which can be implemented in the community pharmacy setting in NHS Scotland. © 2014 John Wiley & Sons, Ltd.

  3. Evaluation of an immunosuppressant side effect instrument.

    Science.gov (United States)

    Winsett, Rebecca P; Arheart, Kris; Stratta, Robert J; Alloway, Rita; Wicks, Mona N; Gaber, A Osama; Hathaway, Donna K

    2004-09-01

    Clinicians continue to be compelled to evaluate the impact of immunosuppressive medication side effects on the quality of life of transplant recipients. We Were asked to develop an instrument to measure side effects in immunosuppressed transplant recipients. To construct an instrument that measures the impact and severity of side effects of immunosuppressive medications used in transplantation and to assess the reliability and validity of the newly developed instrument called the Memphis Survey. The instrument was constructed by a panel of physicians, nurses, and pharmacists with experience in treating transplant recipients. A small group of kidney transplant recipients (n= 13) provided pilot data for refining and testing the instrument. A national sample of kidney, liver, and heart transplant recipients (n = 505) provided data that were used to further develop the instrument. Factor analysis was used to determine the psychological dimensions underlying the instrument and to guide the construction of scales from the survey items. The instrument scales were then computed from the dataset of 505 transplant recipients to quantify the impact of immunosuppressant side effects on the quality of life of transplant recipients. Analyses showed the final instrument scales to be valid and reliable. Exploratory analysis suggests the need for further testing of the instrument to determine gender differences.

  4. Z-Spec: A broadband spectrometer for millimeter-wave astrophysics---Instrument development and results of a molecular line survey of nearby star-forming galaxy NGC 253

    Science.gov (United States)

    Earle, Lieko

    We have built Z-Spec, a broadband spectrometer for millimeter-wave astrophysics. The instrument's instantaneous bandwidth of 185-305 GHz covers the entire 1 millimeter atmospheric transmission window with a moderate resolving power ( R = n/Dn) of 250-350. The spectrometer employs a novel architecture called WaFIRS (Waveguide Far-Infrared Spectrometer) which confines the light propagation for a curved diffraction grating within a parallel-plate waveguide, resulting in a minimum mechanical envelope. An array of 160 silicon- nitride micromesh bolometers is cooled to 60 mK via an adiabatic demagnetization refrigerator (ADR) backed by a closed-cycle 3 He- 4 He sorption pump refrigerator. Z-Spec's compact design serves as a concept demonstration for a future far-infrared spectrometer aboard a cold telescope in space. Routine observations with Z-Spec from the Caltech Submillimeter Observatory on Mauna Kea have been conducted since April 2006, and the instrument currently achieves good sensitivities that are within a factor of two of the photon background limit set by the atmosphere and telescope. Z-Spec's primary science objectives are to determine the redshifts of faint submillimeter galaxies using the 12 CO rotational ladder, and to conduct systematic line surveys of local galaxies. The millimeter waveband hosts low- to mid- J rotational transitions for several molecular species which trace the dense interstellar gas associated with active star formation. Z-Spec's bandwidth offers a unique advantage over the traditional single-dish heterodyne approach: the spectral lines and the corresponding continua are all observed simultaneously, greatly reducing relative uncertainties in flux calibration and line-to-continuum ratios. The starburst galaxy NGC 253 was observed with Z-Spec in November 2006, for a total integration of 3.49 hours over two nights. NGC 253 is one of the brightest neighbors outside the Local Group of galaxies and its compact nuclear region is a site of

  5. Apparatus and method of navigating an instrument

    NARCIS (Netherlands)

    Bakker, N.H.; Den Heeten, G.J.

    2004-01-01

    An apparatus to be used with navigating an instrument in a vascular tree of a patient, comprises a patient's examination table, a C-arm, mounted to which is an X-ray source and an image recorder for registering first X-ray images of the patient, obtained by the use of the X-ray source, and a process

  6. Application of super total station instrument technology in the complex topographic survey%超站仪技术在复杂地形测量中的应用研究

    Institute of Scientific and Technical Information of China (English)

    李国明; 李国庆; 吕健; 吴晓萍

    2011-01-01

    In recent years, due to the rapid development of infrastructure and the conduct of the 5. 12 post-disaster reconstruction in China, topographic measurements increased significantly. However, as many of the construction area of the terrain is more complicated, for measurements made new demands, in addition to improving the conventional measurement methods, more efficient e-quipment are also needed to provide technical support. In this paper, taking Xianxugou 1:500 post-earthquake Geological Disaster Engineering Projects in Jiuzhaigou County of Sichuan Province for example, it introduced the principle of super total station in topographic measurement Combined with the construction area, it discussed the implementation methods, notes, measuring result' s repeatability and reproducibility and so on were analyzed. Finally, a method of measuring in complex terrain was taken. Super total station had more advantage than common measurement instruments in complex topographical surveys. This method would have a significant impact on other surveys.%由于很多施工区域的地形较为复杂,对测量工作提出了新的要求,除改进常规测量方法外,同时需要更高效的仪器提供技术保障.本文以震后四川省九寨沟县鲜浒沟地质灾害工程1:500地形测绘项目为例,介绍了超站仪在地形测量中的应用原理,结合施工区,讨论了其实施方法、注意事项、对测量成果的重复性、复现性等问题进行了分析,提出了复杂地形测量的新方法.实践证明,超站仪在复杂地形测量工作中较常规测量仪器有较大的优势.

  7. Incontinence Symptom Index-Pediatric: development and initial validation of a urinary incontinence instrument for the older pediatric population.

    Science.gov (United States)

    Nelson, Caleb P; Park, John M; Bloom, David A; Wan, Julian; Dunn, Rodney L; Wei, John T

    2007-10-01

    Although urinary incontinence is common in children, no validated pediatric instruments exist for measuring urinary incontinence symptoms and bother. We developed and validated a patient reported pediatric survey for urinary incontinence measurement. The Incontinence Symptom Index-Pediatric is an 11-item instrument comprising 2 domains, that is 1) impairment and 2) symptom severity, including subdomains for stress urinary incontinence, urge urinary incontinence, insensate urinary incontinence, nocturnal urinary incontinence and pad use. The survey was self-administered twice, 2 weeks apart, to boys and girls ages 11 to 17 years. Children completed the survey independently. Cases consisted of patients presenting to pediatric urology clinic with the chief complaint of urinary incontinence. Controls consisted of healthy children presenting for evaluation up at a general pediatric practice. Formal validation analysis was performed. A total of 19 subjects per arm completed at least 1 survey. Internal consistency was good with a Cronbach's alpha of 0.84 for the complete instrument. Item-scale correlations were greater than 0.60 for all except 1 item. Test-retest reliability was also good (r = 0.97, p <0.0001). Discriminative validity was good with a total severity scale score of 9.3 in wet children and 0.7 in controls (p <0.0001). Impairment scale scores differed by 2.2 points (p <0.0001). Mean scores differed significantly between subscales for all domains except pad use. The most dramatic difference was in the urge urinary incontinence domain, which differed by a mean of 3.6 points (p = 0.0002). This pilot study provides initial validation of a survey instrument for urinary incontinence in children and adolescents. This instrument can be used in children ages 11 to 17 years to objectively and reproducibly measure patient reported urinary incontinence.

  8. Evaluating musical instruments

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, D. Murray

    2014-04-01

    Scientific measurements of sound generation and radiation by musical instruments are surprisingly hard to correlate with the subtle and complex judgments of instrumental quality made by expert musicians.

  9. IOT Overview: IR Instruments

    Science.gov (United States)

    Mason, E.

    In this instrument review chapter the calibration plans of ESO IR instruments are presented and briefly reviewed focusing, in particular, on the case of ISAAC, which has been the first IR instrument at VLT and whose calibration plan served as prototype for the coming instruments.

  10. A keyboard for dynamic display and a system comprising the keyboard

    DEFF Research Database (Denmark)

    2011-01-01

    The invention relates to a dynamic display keyboard comprising a plurality of key elements, each key element comprises a transmitting part capable of transmitting at least a part of light incident on the transmitting part; an elastic mat comprising a plurality of elevated elements capable...... keyboard is able to provide a tactile feedback in response to a user action directed towards a key of the keyboard....

  11. Rate Gyroscopic Wellbore Survey System

    Institute of Scientific and Technical Information of China (English)

    Sheng Limin

    1997-01-01

    @@ The rate gyroscopic wellbore survey system as a new type of survey instruments adopts the inertial-grade rate gyro and quartz flexible accelerometers to compose a gyrocompassing system, transiting data to surface instrument by single core cable. The azimuth, inclination and tool-face angle can be computed from these data by surface computer.

  12. Compositions comprising a polypeptide having cellulolytic enhancing activity and a quinone compound and uses thereof

    Energy Technology Data Exchange (ETDEWEB)

    Quinlan, Jason; Xu, Feng; Sweeney, Matthew

    2017-09-05

    The present invention relates to compositions comprising: a polypeptide having cellulolytic enhancing activity and a quinone compound. The present invention also relates to methods of using the compositions.

  13. Compositions comprising a polypeptide having cellulolytic enhancing activity and a bicycle compound and uses thereof

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Feng; Sweeney, Matthew; Quinlan, Jason

    2015-06-16

    The present invention relates to compositions comprising: a polypeptide having cellulolytic enhancing activity and a bicyclic compound. The present invention also relates to methods of using the compositions.

  14. Compositions comprising a polypeptide having cellulolytic enhancing activity and a bicyclic compound and uses thereof

    Energy Technology Data Exchange (ETDEWEB)

    Quinlan, Jason; Xu, Feng; Sweeney, Matthew

    2016-10-04

    The present invention relates to compositions comprising: a polypeptide having cellulolytic enhancing activity and a bicyclic compound. The present invention also relates to methods of using the compositions.

  15. Compositions comprising a polypeptide having cellulolytic enhancing activity and a heterocyclic compound and uses thereof

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Feng; Sweeney, Matthew; Quinlan, Jason

    2016-08-02

    The present invention relates to compositions comprising: a polypeptide having cellulolytic enhancing activity and a heterocyclic compound. The present invention also relates to methods of using the compositions.

  16. Development of the emergency physician job satisfaction measurement instrument.

    Science.gov (United States)

    Lloyd, S; Streiner, D; Hahn, E; Shannon, S

    1994-01-01

    The objective of this study was to develop a valid and reliable instrument to measure the job satisfaction of physicians practicing emergency medicine. A prospective survey involving four separate stages (an item evaluation and reduction stage, a factor analysis stage, a construct validity stage, and a reliability stage) was distributed in Canada to full-time emergency physicians. Three separate survey instruments were administered (an initial draft instrument with 228 items, a pilot instrument with 142 items, and the final instrument with 79 items). Construct validity of the final instrument was tested by evaluating the correlation between physician scores on the instrument, and scores on two instruments measuring the same construct, and three measuring different but related constructs. A draft instrument with 228 items and six hypothetical domains was tested on 61 physicians. Evaluation for frequency endorsement, redundancy, and homogeneity reduced the item pool to 157. The remaining 157 items were used as a pilot instrument and tested on 223 physicians. Factor analysis eliminated 66 items from the pilot instrument, creating a final instrument with 79 items, 11 factors, and six domains. Cronbach's coefficient alpha for the final instrument domains is 0.81, and all domain-total correlations are greater than 0.4. All correlations between the final instrument and the construct validity instruments were statistically significant (P job satisfaction, which is both internally consistent and stable.

  17. Method and apparatus for separating a non-ferrous metal-comprising fraction from ferrous scrap

    NARCIS (Netherlands)

    Rem, P.C.; Berkhout, S.P.M.

    2010-01-01

    Method for separating a non-ferrous metal-comprising fraction from ferrous scrap, wherein the ferrous scrap is conveyed to a processing device for separating the non-ferrous metal-comprising fraction from the remainder of the ferrous scrap. The processing device supplies a beam of water, and the fer

  18. Polymer coating comprising 2-methoxyethyl acrylate units synthesized by surface-initiated atom transfer radical polymerization

    DEFF Research Database (Denmark)

    2011-01-01

    Source: US2012184029A The present invention relates to preparation of a polymer coating comprising or consisting of polymer chains comprising or consisting of units of 2-methoxyethyl acrylate synthesized by Surface-Initiated Atom Transfer Radical Polymerization (SI ATRP) such as ARGET SI ATRP...... or AGET SI ATRP and uses of said polymer coating....

  19. Method for recovering aroma concentrate from a caffeine- or theobromine-comprising food base material

    NARCIS (Netherlands)

    Kattenberg, H.R.; Willemsen, J.H.A.; Starmans, D.A.J.; Hoving, H.D.; Winters, M.G.M.

    2002-01-01

    Described is a method for recovering aroma concentrate from a caffeine- or theobromine-comprising food base material, such as coffee or tea, and in particular cocoa, at least comprising the steps of: introducing the food base material into an aqueous extractant and incubating the food base material

  20. Molecular sleds comprising a positively -charged amino acid sequence and a molecular cargo and uses thereof

    NARCIS (Netherlands)

    MANGEL, WALTER, F; BLAINEY, PAUL; GRAZIANO, VITO; HERRMANN, ANDREAS; MCGRATH, WILLIAM, J; VAN OIJEN, ANTONIUS, MARTINUS; XIE, XIAOLIANG, SUNNEY

    2014-01-01

    The present invention relates to compositions which may comprise a molecular sled linked to cargo and uses thereof. In particular, the present invention relates to a non-naturally occurring or engineered composition which may comprise a molecular sled, linkers and a molecular cargo connected to the

  1. Ball bearings comprising nickel-titanium and methods of manufacture thereof

    Science.gov (United States)

    DellaCorte, Christopher (Inventor); Glennon, Glenn N. (Inventor)

    2012-01-01

    Disclosed herein is a friction reducing nickel-titanium composition. The nickel-titanium composition includes a first phase that comprises nickel and titanium in an atomic ratio of about 0.45:0.55 to about 0.55:0.45; a second phase that comprises nickel and titanium in an atomic ratio of about 0.70:0.30 to about 0.80:0.20; and a third phase that comprises nickel and titanium in an atomic ratio of about 0.52:0.48 to about 0.62:0.38. A bearing for reducing friction comprising a nickel-titanium composition comprising a first phase that comprises nickel and titanium in an atomic ratio of about 0.45:0.55 to about 0.55:0.45; a second phase that comprises nickel and titanium in an atomic ratio of about 0.70:0.30 to about 0.80:0.20; and a third phase that comprises nickel and titanium in an atomic ratio of about 0.52:0.48 to about 0.62:0.38; where the bearing is free from voids and pinholes.

  2. Electrode material comprising graphene-composite materials in a graphite network

    Energy Technology Data Exchange (ETDEWEB)

    Kung, Harold H.; Lee, Jung K.

    2017-08-08

    A durable electrode material suitable for use in Li ion batteries is provided. The material is comprised of a continuous network of graphite regions integrated with, and in good electrical contact with a composite comprising graphene sheets and an electrically active material, such as silicon, wherein the electrically active material is dispersed between, and supported by, the graphene sheets.

  3. Electrode material comprising graphene-composite materials in a graphite network

    Energy Technology Data Exchange (ETDEWEB)

    Kung, Harold H.; Lee, Jung K.

    2014-07-15

    A durable electrode material suitable for use in Li ion batteries is provided. The material is comprised of a continuous network of graphite regions integrated with, and in good electrical contact with a composite comprising graphene sheets and an electrically active material, such as silicon, wherein the electrically active material is dispersed between, and supported by, the graphene sheets.

  4. Method and apparatus for separating a non-ferrous metal-comprising fraction from ferrous scrap

    NARCIS (Netherlands)

    Rem, P.C.; Berkhout, S.P.M.

    2010-01-01

    Method for separating a non-ferrous metal-comprising fraction from ferrous scrap, wherein the ferrous scrap is conveyed to a processing device for separating the non-ferrous metal-comprising fraction from the remainder of the ferrous scrap. The processing device supplies a beam of water, and the

  5. Graduate Assessment Survey Report.

    Science.gov (United States)

    Santa Fe Community Coll., Gainesville, FL. Office of Institutional Research and Planning.

    Determines the degree to which Santa Fe Community College (Florida) is providing quality educational programs and services to its students. Surveys outgoing students to gather their opinions and perceptions of the educational experiences and services they received while attending the college. The survey instrument is divided into three sections:…

  6. Instrument Modeling and Synthesis

    Science.gov (United States)

    Horner, Andrew B.; Beauchamp, James W.

    During the 1970s and 1980s, before synthesizers based on direct sampling of musical sounds became popular, replicating musical instruments using frequency modulation (FM) or wavetable synthesis was one of the “holy grails” of music synthesis. Synthesizers such as the Yamaha DX7 allowed users great flexibility in mixing and matching sounds, but were notoriously difficult to coerce into producing sounds like those of a given instrument. Instrument design wizards practiced the mysteries of FM instrument design.

  7. Performing the Super Instrument

    DEFF Research Database (Denmark)

    Kallionpaa, Maria

    2016-01-01

    The genre of contemporary classical music has seen significant innovation and research related to new super, hyper, and hybrid instruments, which opens up a vast palette of expressive potential. An increasing number of composers, performers, instrument designers, engineers, and computer programmers...... provides the performer extensive virtuoso capabilities in terms of instrumental range, harmony, timbre, or spatial, textural, acoustic, technical, or technological qualities. The discussion will be illustrated by a composition case study involving augmented musical instrument electromagnetic resonator...

  8. Performing the Super Instrument

    DEFF Research Database (Denmark)

    Kallionpaa, Maria

    2016-01-01

    provides the performer extensive virtuoso capabilities in terms of instrumental range, harmony, timbre, or spatial, textural, acoustic, technical, or technological qualities. The discussion will be illustrated by a composition case study involving augmented musical instrument electromagnetic resonator......The genre of contemporary classical music has seen significant innovation and research related to new super, hyper, and hybrid instruments, which opens up a vast palette of expressive potential. An increasing number of composers, performers, instrument designers, engineers, and computer programmers...

  9. Aeroacoustics of Musical Instruments

    NARCIS (Netherlands)

    Fabre, B.; Gilbert, J.; Hirschberg, A.; Pelorson, X.

    2012-01-01

    We are interested in the quality of sound produced by musical instruments and their playability. In wind instruments, a hydrodynamic source of sound is coupled to an acoustic resonator. Linear acoustics can predict the pitch of an instrument. This can significantly reduce the trial-and-error process

  10. [Survey of analytical work done for drugs at the emergency and critical care centers equipped with high-performance instruments provided by the Ministry of Health and Welfare (at present: Ministry of Health, Labour and Welfare) in fiscal 1998].

    Science.gov (United States)

    Hori, Yasushi; Iseki, Ken; Suzuki, Koichiro; Namera, Akira; Fukumoto, Mariko; Fuke, Chiaki; Mori, Hiromi; Soma, Kazui

    2010-09-01

    A questionnaire was sent to 73 emergency and critical care centers where high-performance instruments for analyzing drugs and chemicals were provided by the Ministry of Health and Welfare (currently Ministry of Health, Labour and Welfare) in fiscal 1998. 52 centers (71.2%) responded to the questionnaire. Among these, the instruments have been in operation at 36 centers. This means that analytical work has been performed in at least 49.3% (36/73) of facilities with the instruments. A positive correlation was observed between the annual number of patients tested for drugs and chemicals and analytical work hours at the 36 facilities. The results indicated that 150 cases may be tested for drugs and chemicals in a year on the condition that 100 hours a month of analytical work are secured, and 200 or more cases may be tested if 200 hours a month are secured. As for the running costs required for the operation of the instruments, the instrument maintenance and repair cost was estimated at 2 million yen a year, and it was calculated that 100 cases could be handled with a maximum annual supply expense of 1 million yen and 150 cases could be handled with a maximum annual supply expense of 2 million yen. These results suggest that the instrument running cost would be fully covered at nationwide emergency and critical care centers if the additional 5,000 NHI points (1 point = 10 yen) for hospital admission, which is approved for advanced emergency and critical care centers, were applicable to all facilities. Among the 36 facilities, the implementation of analysis varied for each of the 15 toxic substances recommended for analysis by the Japanese Society for Clinical Toxicology. Further research will be necessary to investigate and assess the frequency of analysis requests and combination of simple qualitative and instrumental analyses for each of the 15 substances, in order to evaluate the approach to the 15 substances in analytical work.

  11. Nanolipoprotein particles comprising a natural rubber biosynthetic enzyme complex and related products, methods and systems

    Energy Technology Data Exchange (ETDEWEB)

    Hoeprich, Paul D.; Whalen, Maureen

    2016-04-05

    Provided herein are nanolipoprotein particles that comprise a biosynthetic enzyme more particularly an enzyme capable of catalyzing rubber or other rubbers polymerization, and related assemblies, devices, methods and systems.

  12. Alignment of Carbon Nanotubes Comprising Magnetically Sensitive Metal Oxides in Nanofluids

    Science.gov (United States)

    Hong, Haiping (Inventor); Peterson, G. P. " Bud" (Inventor)

    2016-01-01

    The present invention is a nanoparticle mixture or suspension or nanofluid comprising nonmagnetically sensitive nanoparticles, magnetically sensitive nanoparticles, and surfactant(s). The present invention also relates to methods of preparing and using the same.

  13. Thermally stable drilling fluid additive comprised of a copolymer of catechol-based monomer

    Energy Technology Data Exchange (ETDEWEB)

    Patel, A.D.

    1986-06-17

    A water soluble polymer is described having thermal stability and exhibiting utility as an aqueous drilling fluid additive comprising: (a) a major portion of a catechol based monomer; (b) a minor portion of a dicarboxylic acid monomer.

  14. Pharmaceutical compositions comprising lubricants for preventing or reducing aseptic loosening in a subject

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to pharmaceutical compositions comprising one or more amphiphilic polymer lubricants for use in association with artificial orthopaedic implants. Additionally, the invention relates to medical use of the lubricants of the invention in connection with conditions...... associated with artificial5 orthopaedic implants. The invention furthermore relates to artificial joint implants comprising the polymer lubricants according to the invention and methods for preparing such implants....

  15. Industry survey of the need for a Federal grant-assisted geothermal demonstration power plant. Final report

    Energy Technology Data Exchange (ETDEWEB)

    1978-06-01

    Findings are presented from two separate studies: a preliminary study of leaders of the geothermal industry and a second study of a ten percent representative sample of other firms. The studies are intended to determine if a need still exists for a federal grant-assisted geothermal demonstration power plant. The following are included: selection of the survey samples from the population comprising the geothermal industry; the development of the survey instrument; the collection and analysis of the results; and a summary. The responses of financial firms are discussed. (MHR)

  16. Development of the European Health Interview Survey - Physical Activity Questionnaire (EHIS-PAQ) to monitor physical activity in the European Union

    OpenAIRE

    Finger, Jonas D.; Tafforeau, Jean; Gisle, Lydia; Oja, Leila; Ziese, Thomas; Thelen, Juergen; Mensink, Gert B. M.; Lange, Cornelia

    2015-01-01

    Background A domain-specific physical activity questionnaire (EHIS-PAQ) was developed in the framework of the second wave of the European Health Interview Survey (EHIS). This article presents the EHIS-PAQ and describes its development and evaluation processes. Methods Research institutes from Belgium, Estonia and Germany participated in the Improvement of the EHIS (ImpEHIS) Grant project issued by Eurostat. The instrument development process comprised a non-systematic literature review and a ...

  17. The Dark Energy Spectroscopic Instrument (DESI)

    Science.gov (United States)

    Flaugher, Brenna; Bebek, Chris

    2014-07-01

    The Dark Energy Spectroscopic Instrument (DESI) is a Stage IV ground-based dark energy experiment that will study baryon acoustic oscillations (BAO) and the growth of structure through redshift-space distortions with a wide-area galaxy and quasar spectroscopic redshift survey. The DESI instrument consists of a new wide-field (3.2 deg. linear field of view) corrector plus a multi-object spectrometer with up to 5000 robotically positioned optical fibers and will be installed at prime focus on the Mayall 4m telescope at Kitt Peak, Arizona. The fibers feed 10 three-arm spectrographs producing spectra that cover a wavelength range from 360-980 nm and have resolution of 2000-5500 depending on the wavelength. The DESI instrument is designed for a 14,000 sq. deg. multi-year survey of targets that trace the evolution of dark energy out to redshift 3.5 using the redshifts of luminous red galaxies (LRGs), emission line galaxies (ELGs) and quasars. DESI is the successor to the successful Stage-III BOSS spectroscopic redshift survey and complements imaging surveys such as the Stage-III Dark Energy Survey (DES, currently operating) and the Stage-IV Large Synoptic Survey Telescope (LSST, planned start early in the next decade).

  18. Public surveys at ESO

    Science.gov (United States)

    Arnaboldi, Magda; Delmotte, Nausicaa; Hilker, Michael; Hussain, Gaitee; Mascetti, Laura; Micol, Alberto; Petr-Gotzens, Monika; Rejkuba, Marina; Retzlaff, Jörg; Mieske, Steffen; Szeifert, Thomas; Ivison, Rob; Leibundgut, Bruno; Romaniello, Martino

    2016-07-01

    ESO has a strong mandate to survey the Southern Sky. In this article, we describe the ESO telescopes and instruments that are currently used for ESO Public Surveys, and the future plans of the community with the new wide-field-spectroscopic instruments. We summarize the ESO policies governing the management of these projects on behalf of the community. The on-going ESO Public Surveys and their science goals, their status of completion, and the new projects selected during the second ESO VISTA call in 2015/2016 are discussed. We then present the impact of these projects in terms of current numbers of refereed publications and the scientific data products published through the ESO Science Archive Facility by the survey teams, including the independent access and scientific use of the published survey data products by the astronomical community.

  19. Marine chemistry, fish / shell-fish surveys, benthic organisms, and marine toxic substances and pollutants data from current meter and other instruments in the Gulf of Mexico from 26 January 1993 to 13 June 1994 (NODC Accession 9500088)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Marine chemistry, fish / shell-fish surveys, benthic organisms, and marine toxic substances and pollutants data were collected using current meter and other...

  20. VIRUS instrument enclosures

    Science.gov (United States)

    Prochaska, T.; Allen, R.; Mondrik, N.; Rheault, J. P.; Sauseda, M.; Boster, E.; James, M.; Rodriguez-Patino, M.; Torres, G.; Ham, J.; Cook, E.; Baker, D.; DePoy, Darren L.; Marshall, Jennifer L.; Hill, G. J.; Perry, D.; Savage, R. D.; Good, J. M.; Vattiat, Brian L.

    2014-08-01

    The Visible Integral-Field Replicable Unit Spectrograph (VIRUS) instrument will be installed at the Hobby-Eberly Telescope† in the near future. The instrument will be housed in two enclosures that are mounted adjacent to the telescope, via the VIRUS Support Structure (VSS). We have designed the enclosures to support and protect the instrument, to enable servicing of the instrument, and to cool the instrument appropriately while not adversely affecting the dome environment. The system uses simple HVAC air handling techniques in conjunction with thermoelectric and standard glycol heat exchangers to provide efficient heat removal. The enclosures also provide power and data transfer to and from each VIRUS unit, liquid nitrogen cooling to the detectors, and environmental monitoring of the instrument and dome environments. In this paper, we describe the design and fabrication of the VIRUS enclosures and their subsystems.

  1. Gemini Instrument Upgrade Program

    Science.gov (United States)

    Diaz, Ruben; Goodsell, Stephen; Kleinman, Scot

    2016-08-01

    The Gemini Observatory* remains committed to keeping its operational instrumentation competitive and serving the needs of its user community. Currently the observatory operates a 4 instruments + 1 AO system at each site. At Gemini North the GMOS-N, GNIRS, NIFS and NIRI instruments are offered supported by the ALTAIR AO system. In the south, GMOS-S, F-2, GPI and GSAOI are offered instrumentation and GeMS is the provided AO System. This paper reviews our strategy to keep our instrumentation suite competitive, examines both our current funded upgrade projects and our potential future enhancements. We summarize the work done and the results so far obtained within the instrument upgrade program.

  2. Instrumentation a reader

    CERN Document Server

    Pope, P

    1990-01-01

    This book contains a selection of papers and articles in instrumentation previously pub­ lished in technical periodicals and journals of learned societies. Our selection has been made to illustrate aspects of current practice and applications of instrumentation. The book does not attempt to be encyclopaedic in its coverage of the subject, but to provide some examples of general transduction techniques, of the sensing of particular measurands, of components of instrumentation systems and of instrumentation practice in two very different environments, the food industry and the nuclear power industry. We have made the selection particularly to provide papers appropriate to the study of the Open University course T292 Instrumentation. The papers have been chosen so that the book covers a wide spectrum of instrumentation techniques. Because of this, the book should be of value not only to students of instrumen­ tation, but also to practising engineers and scientists wishing to glean ideas from areas of instrumen...

  3. Towards an Enterprise Architecture Benefits Measurement Instrument

    NARCIS (Netherlands)

    Plessius, Henk; Steenbergen, van Marlies; Slot, Raymond

    2015-01-01

    Author supplied: Based on the Enterprise Architecture Value Framework (EAVF) - a generic framework to classify benefits of Enterprise Architecture (EA) - a measurement instrument for EA benefits has been developed and tested in a survey with 287 respondents. In this paper we present the results of

  4. Locating Tests and Measurement Instruments for Assessment

    Science.gov (United States)

    Mastel, Kristen; Morris-Knower, Jim; Marsalis, Scott

    2016-01-01

    Extension educators, staff, and specialists need to use surveys and other measurement instruments to assess their programming and conduct other research. Challenges in locating tests and measurement tools, however, include lack of time and lack of familiarity with techniques that can be used to find them. This article discusses library resources…

  5. Aircrew Screening Instruments Review

    Science.gov (United States)

    2007-09-01

    available tools . Several vendors indicated that they will have new selection instruments available within a few months. These are not listed. As noted...AFCAPS-FR-2011-0012 AIRCREW SCREENING INSTRUMENTS REVIEW Diane L. Damos Damos Aviation Services, Inc...June 2007 – August 2007 4. TITLE AND SUBTITLE Aircrew Screening Instruments Review 5a. CONTRACT NUMBER FA3089-06-F-0385 5b. GRANT NUMBER 5c

  6. [Controlling instruments in radiology].

    Science.gov (United States)

    Maurer, M

    2013-10-01

    Due to the rising costs and competitive pressures radiological clinics and practices are now facing, controlling instruments are gaining importance in the optimization of structures and processes of the various diagnostic examinations and interventional procedures. It will be shown how the use of selected controlling instruments can secure and improve the performance of radiological facilities. A definition of the concept of controlling will be provided. It will be shown which controlling instruments can be applied in radiological departments and practices. As an example, two of the controlling instruments, material cost analysis and benchmarking, will be illustrated.

  7. Ocean Optics Instrumentation Systems

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Provides instrumentation suites for a wide variety of measurements to characterize the ocean’s optical environment. These packages have been developed to...

  8. Networked Instrumentation Element

    Data.gov (United States)

    National Aeronautics and Space Administration — Armstrong researchers have developed a networked instrumentation system that connects modern experimental payloads to existing analog and digital communications...

  9. Satellite oceanography - The instruments

    Science.gov (United States)

    Stewart, R. H.

    1981-01-01

    It is pointed out that no instrument is sensitive to only one oceanographic variable; rather, each responds to a combination of atmospheric and oceanic phenomena. This complicates data interpretation and usually requires that a number of observations, each sensitive to somewhat different phenomena, be combined to provide unambiguous information. The distinction between active and passive instruments is described. A block diagram illustrating the steps necessary to convert data from satellite instruments into oceanographic information is included, as is a diagram illustrating the operation of a radio-frequency radiometer. Attention is also given to the satellites that carry the various oceanographic instruments.

  10. PEP Laser Surveying System

    Energy Technology Data Exchange (ETDEWEB)

    Lauritzen, T.; Sah, R.C.

    1979-03-01

    A Laser Surveying System has been developed to survey the beam elements of the PEP storage ring. This system provides automatic data acquisition and analysis in order to increase survey speed and to minimize operator error. Two special instruments, the Automatic Readout Micrometer and the Small Automatic Micrometer, have been built for measuring the locations of fiducial points on beam elements with respect to the light beam from a laser. These instruments automatically encode offset distances and read them into the memory of an on-line computer. Distances along the beam line are automatically encoded with a third instrument, the Automatic Readout Tape Unit. When measurements of several beam elements have been taken, the on-line computer analyzes the measured data, compared them with desired parameters, and calculates the required adjustments to beam element support stands.

  11. Apparatus comprising trace element dosage and method for treating raw water in biofilter

    DEFF Research Database (Denmark)

    2015-01-01

    : - the filter comprises a filter material (4) including a porous filter material and a microbial biomass, the filter material is either stationary relative to the volume or comprises a particulate material, the filter material (4) is inserted in a fluid flow path generated by water flowing in direction from...... the inlet (2) to the outlet (3) or in the reverse direction, - the trace element dosage device (13) is positioned upstream of the porous filter material and microbial biomass and is configured to dose trace element(s) to the water flowing through the filter. A method for treating raw water by microbial...

  12. Structural tensegrity module and two-layer structural mesh comprising said module

    OpenAIRE

    Gómez Jáuregui, Valentín; Otero González, César Antonio; Arias Fernández, Rubén; Manchado del Val, Cristina

    2013-01-01

    ABSTRACT. The invention relates to a structural tensegrity module contained in a prism defined by a lower base and an upper base having 2n sides, comprising 2n lower corner nodes aligned with the vertices of the lower base and 2n lower intermediate nodes aligned with the mid-point of each side of the lower base, and 2n upper corner nodes aligned with the vertices of the upper base and 2n upper intermediate nodes aligned with the mid-point of each side of the upper base. The module comprises a...

  13. Method and apparatus for separating a non-ferrous metal-comprising fraction from ferrous scrap

    OpenAIRE

    Rem, P.C.; Berkhout, S.P.M.

    2010-01-01

    Method for separating a non-ferrous metal-comprising fraction from ferrous scrap, wherein the ferrous scrap is conveyed to a processing device for separating the non-ferrous metal-comprising fraction from the remainder of the ferrous scrap. The processing device supplies a beam of water, and the ferrous scrap is conveyed and released into the waterbeam so as to cause that the ferrous scrap is allowed to fall and move further, subject to the forces of gravity and the waterbeam.

  14. Instrumentation Design and Development Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — RTTC has facilities for design, development and fabrication of: custominstrumentation, mobile instrumentation, miniaturized instrumentation, wirelessinstrumentation,...

  15. BAA instrument no. 93

    Science.gov (United States)

    Marriott, R. A.

    2006-12-01

    Instrument no. 93 has been in almost continual use for more than a hundred years. Since it left the workshop of its maker, George Calver, it has kept company with several other notable instruments and has been used by many eminent astronomers. It was added to the Association's collection in 1945.

  16. Instrumentation in endourology

    OpenAIRE

    Khanna, Rakesh; Monga,Manoj

    2011-01-01

    Success with endourological procedures requires expertise and instrumentation. This review focuses on the instrumentation required for ureteroscopy and percutaneous nephrolithotomy, and provides a critical assessment of in vitro and clinical studies that have evaluated the comparative effectiveness of these medical devices.

  17. Photomlxer for terahertz electromagnetic wave emission comprising quantum dots in a laser cavity

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to a photomixer for generating terahertz electromagnetic radiation in response to illumination by a time-modulated optical signal. The photomixer (300) comprises a carrier substrate (310) with a plurality of quantum dots arranged in an emission region (308) thereof...

  18. Palladium catalyst system comprising zwitterion and/or acid-​functionalized ionic liquid

    DEFF Research Database (Denmark)

    2011-01-01

    The present invention concerns a catalyst system in particular a catalyst system comprising Palladium (Pd), a zwitterion and/or an acid-functionalized ionic liquid, and one or more phosphine ligands, wherein the Pd catalyst can be provided by a complex precursor, such as Pd(CH3COO)2, PdCI2, Pd(CH3...

  19. Palladium catalyst system comprising zwitterion and/or acid-functionalized ionic liquid

    DEFF Research Database (Denmark)

    2011-01-01

    The present invention concerns a catalyst system in particular a catalyst system comprising Palladium (Pd), a zwitterion and/or an acid-functionalized ionic liquid, and one or more phosphine ligands, wherein the Pd catalyst can be provided by a complex precursor, such as Pd(CH3COO)2, PdCI2, Pd(CH3...

  20. Non-aqueous liquid compositions comprising ion exchange polymers reference to related application

    Science.gov (United States)

    Kim; Yu Seung , Lee; Kwan-Soo , Rockward; Tommy Q. T.

    2012-08-07

    Compositions, and methods of making thereof, comprising from about 1% to about 5% of a perfluorinated sulfonic acid ionomer or a hydrocarbon-based ionomer; and from about 95% to about 99% of a solvent, said solvent consisting essentially of a polyol; wherein said composition is substantially free of water and wherein said ionomer is uniformly dispersed in said solvent.

  1. Combination Comprising Parthenolide For Use In The Treatment Of Alzheimer's Disease And Other Neurodegenerative Disorders

    KAUST Repository

    Bajic, Vladimir B.

    2015-06-18

    The present invention generally concerns particular methods and compositions for treatment of a neurodegenerative disease, such as Alzheimer\\'s Disease. In particular embodiments, there is a composition comprising Parthenolide and a second agent, including an inhibitor of TLR4/MD-2/CD14, nAChR agonist, Resatorvid, Curcumin, Tilorone or a Tilorone analog, or a combination thereof.

  2. Polymer foam comprising a polymer and nanoparticles, and nanoparticles for the manufacture of such foam.

    NARCIS (Netherlands)

    Vancso, Gyula J.; Duvigneau, Joost; Nederkoorn, P.H.J.; Wassing, T.

    2014-01-01

    A polymer foam is produced comprising a polymer and nanoparticles having a maximum dimensionof 750 nm, which foam has cells with an average cell size of at most 1 µm and a cell density of at least 1012 cells/ml, wherein polymeric grafts have been attached to the nanoparticles. The nanoparticles may

  3. Polymer foam comprising a polymer and nanoparticles, and nanoparticles for the manufacture of such foam.

    NARCIS (Netherlands)

    Vancso, G.J.; Duvigneau, J.; Nederkoorn, P.H.J.; Wassing, T.

    2014-01-01

    A polymer foam is produced comprising a polymer and nanoparticles having a maximum dimensionof 750 nm, which foam has cells with an average cell size of at most 1 µm and a cell density of at least 1012 cells/ml, wherein polymeric grafts have been attached to the nanoparticles. The nanoparticles may

  4. Light source comprising a common substrate, a first led device and a second led device

    Science.gov (United States)

    Choong, Vi-En

    2010-02-23

    At least one stacked organic or polymeric light emitting diode (PLEDs) devices to comprise a light source is disclosed. At least one of the PLEDs includes a patterned cathode which has regions which transmit light. The patterned cathodes enable light emission from the PLEDs to combine together. The light source may be top or bottom emitting or both.

  5. The minimal essential unit for cadherin-mediated intercellular adhesion comprises extracellular domains 1 and 2

    DEFF Research Database (Denmark)

    Shan, Weisong; Yagita, Yoshiki; Wang, Zhaohui

    2004-01-01

    N-cadherin comprises five homologous extracellular domains, a transmembrane, and a cytoplasmic domain. The extracellular domains of N-cadherin play important roles in homophilic cell adhesion, but the contribution of each domain to this phenomenon has not been fully evaluated. In particular, the ...

  6. New mesogenic Schiff base esters comprising benzothiazole moiety:Synthesis and mesomorphic properties

    Institute of Scientific and Technical Information of China (English)

    Sie Tiong Ha; Teck Ming Koh; Guan Yeow Yeap; Hong Cheu Lin; Jun Kit Beh; Yip Foo Win; Peng Lim Boey

    2009-01-01

    A homologous series of Schiff base esters,6-methoxy-2-(2-hydroxy-4-alkanoyloxybenzylidenamino)benzothiazoles,comprising a benzothiazole moiety as the core was synthesized.All the members of this series exhibited an enantiotropic nematic phase.The azomethine linkage along with the lateral hydroxyl and terminal methoxyl groups were found to exert an effect on the mesomorphic properties.

  7. Intraoral Pressure in Ethnic Wind Instruments

    CERN Document Server

    Goss, Clinton F

    2013-01-01

    High intraoral pressure generated when playing some wind instruments has been linked to a variety of health issues. Prior research has focused on Western classical instruments, but no work has been published on ethnic wind instruments. This study measured intraoral pressure when playing six classes of ethnic wind instruments (N = 149): Native American flutes (n = 71) and smaller samples of ethnic duct flutes, reed instruments, reedpipes, overtone whistles, and overtone flutes. Results are presented in the context of a survey of prior studies, providing a composite view of the intraoral pressure requirements of a broad range of wind instruments. Mean intraoral pressure was 8.37 mBar across all ethnic wind instruments and 5.21 +/- 2.16 mBar for Native American flutes. The range of pressure in Native American flutes closely matches pressure reported in other studies for normal speech, and the maximum intraoral pressure, 20.55 mBar, is below the highest subglottal pressure reported in other studies during singing...

  8. INSTRUMENTATION FOR ENVIRONMENTAL MONITORING--Radiation--Vol3Pt1

    Energy Technology Data Exchange (ETDEWEB)

    Authors, Various

    1972-01-02

    A comprehensive survey of instrumentation for environmental monitoring is being carried out by the Lawrence Berkeley Laboratory originally under a grant from the National Science Foundation and now by the Office of Health and Environmental Research of the Department of Energy. Instruments being investigated are those useful for measurements in Air Quality, Water Quality, Radiation, and Biomedicine related to environmental research and monitoring. Consideration is given to instruments and techniques presently in use and to those developed for other purposes but having possible applications to this work. The results of the survey are given as (a) descriptions of the physical and operating characteristics of available instruments, (b) critical comparisons among instrumentation methods, and (c) recommendations of promising methodology and development of new instrumentation. Information is also given regarding the pollutants to be monitored: their characteristics and forms, their sources and pathways, their effects on the ecosystem, and the means of controlling them through process and regulatory controls.

  9. Human factors aspects of advanced instrumentation in the nuclear industry

    Energy Technology Data Exchange (ETDEWEB)

    Carter, R.J.

    1989-01-01

    An important consideration in regards to the use of advanced instrumentation in the nuclear industry is the interface between the instrumentation system and the human. A survey, oriented towards identifying the human factors aspects of digital instrumentation, was conducted at a number of United States (US) and Canadian nuclear vendors and utilities. Human factors issues, subsumed under the categories of computer-generated displays, controls, organizational support, training, and related topics were identified. 20 refs., 2 tabs.

  10. Instrumentation reference book

    CERN Document Server

    Boyes, Walt

    2002-01-01

    Instrumentation is not a clearly defined subject, having a 'fuzzy' boundary with a number of other disciplines. Often categorized as either 'techniques' or 'applications' this book addresses the various applications that may be needed with reference to the practical techniques that are available for the instrumentation or measurement of a specific physical quantity or quality. This makes it of direct interest to anyone working in the process, control and instrumentation fields where these measurements are essential.* Comprehensive and authoritative collection of technical information* Writte

  11. Medical instruments in museums

    DEFF Research Database (Denmark)

    Söderqvist, Thomas; Arnold, Ken

    2011-01-01

    This essay proposes that our understanding of medical instruments might benefit from adding a more forthright concern with their immediate presence to the current historical focus on simply decoding their meanings and context. This approach is applied to the intriguingly tricky question of what...... actually is meant by a "medical instrument." It is suggested that a pragmatic part of the answer might lie simply in reconsidering the holdings of medical museums, where the significance of the physical actuality of instruments comes readily to hand....

  12. Mass spectrometers: instrumentation

    Science.gov (United States)

    Cooks, R. G.; Hoke, S. H., II; Morand, K. L.; Lammert, S. A.

    1992-09-01

    Developments in mass spectrometry instrumentation over the past three years are reviewed. The subject is characterized by an enormous diversity of designs, a high degree of competition between different laboratories working with either different or similar techniques and by extremely rapid progress in improving analytical performance. Instruments can be grouped into genealogical charts based on their physical and conceptual interrelationships. This is illustrated using mass analyzers of different types. The time course of development of particular instrumental concepts is illustrated in terms of the s-curves typical of cell growth. Examples are given of instruments which are at the exponential, linear and mature growth stages. The prime examples used are respectively: (i) hybrid instruments designed to study reactive collisions of ions with surfaces: (ii) the Paul ion trap; and (iii) the triple quadrupole mass spectrometer. In the area of ion/surface collisions, reactive collisions such as hydrogen radical abstraction from the surface by the impinging ion are studied. They are shown to depend upon the chemical nature of the surface through the use of experiments which utilize self-assembled monolayers as surfaces. The internal energy deposited during surface-induced dissociation upon collision with different surfaces in a BEEQ instrument is also discussed. Attention is also given to a second area of emerging instrumentation, namely technology which allows mass spectrometers to be used for on-line monitoring of fluid streams. A summary of recent improvements in the performance of the rapidly developing quadrupole ion trap instrument illustrates this stage of instrument development. Improvements in resolution and mass range and their application to the characterization of biomolecules are described. The interaction of theory with experiment is illustrated through the role of simulations of ion motion in the ion trap. It is emphasized that mature instruments play a

  13. Manual of Surgical Instruments

    Directory of Open Access Journals (Sweden)

    Olga Lidia Sánchez Sarría

    2014-10-01

    Full Text Available Surgical instruments are the group of tools used in surgical procedures. They are very expensive and sophisticated. Consequently, a standardized and meticulous care is essential; they should go through the decontamination, cleaning and sterilization process. These instruments are designed in order to provide surgeons with tools that help them to perform a basic surgical procedure; there are multiple variations and the design depends on their function. This paper aims at showing all surgical instruments that can be used in an operating room during surgery and are not generally included in the medical literature.

  14. Biomedical Sensors and Instruments

    CERN Document Server

    Tagawa, Tatsuo

    2011-01-01

    The living body is a difficult object to measure: accurate measurements of physiological signals require sensors and instruments capable of high specificity and selectivity that do not interfere with the systems under study. As a result, detailed knowledge of sensor and instrument properties is required to be able to select the "best" sensor from one of the many designed to meet these challenges. From the underlying principles to practical applications, this updated edition of Biomedical Sensors and Instruments provides an easy-to-understand introduction to the various kinds of biome

  15. Canadian contributions studies for the WFIRST instruments

    Science.gov (United States)

    Lavigne, J.-F.; Rowlands, N.; Grandmont, F. J.; Lafrenière, D.; Marois, C.; Daigle, O.; Thibault, S.; Schade, D.; Artigau, É.; Brousseau, D.; Maire, J.; Cretot-Richert, G.; Ducharme, M.-È.; Levesque, L. E.; Laurin, D.; Dupuis, J.

    2016-07-01

    WFIRST-AFTA is the NASA's highest ranked astrophysics mission for the next decade that was identified in the New World, New Horizon survey. The mission scientific drivers correspond to some of the deep questions identified in the Canadian LRP2010, and are also of great interest for the Canadian scientists. Given that there is also a great interest in having an international collaboration in this mission, the Canadian Space Agency awarded two contracts to study a Canadian participation in the mission, one related to each instrument. This paper presents a summary of the technical contributions that were considered for a Canadian contribution to the coronagraph and wide field instruments.

  16. The DESI Experiment Part II: Instrument Design

    OpenAIRE

    DESI Collaboration; Aghamousa, Amir; Aguilar, Jessica; Ahlen, Steve; Alam, Shadab; Allen, Lori E.; Prieto, Carlos Allende; Annis, James; Bailey, Stephen; Balland, Christophe; Ballester, Otger; Baltay, Charles; Beaufore, Lucas; Bebek, Chris; Beers, Timothy C.

    2016-01-01

    DESI (Dark Energy Spectropic Instrument) is a Stage IV ground-based dark energy experiment that will study baryon acoustic oscillations and the growth of structure through redshift-space distortions with a wide-area galaxy and quasar redshift survey. The DESI instrument is a robotically-actuated, fiber-fed spectrograph capable of taking up to 5,000 simultaneous spectra over a wavelength range from 360 nm to 980 nm. The fibers feed ten three-arm spectrographs with resolution $R= \\lambda/\\Delta...

  17. Microchannel apparatus comprising plural microchannels and methods of conducting unit operations

    Science.gov (United States)

    Wegeng, Robert S [Richland, WA; TeGrotenhuis, Ward E [Kennewick, WA; Whyatt, Greg A [West Richland, WA

    2009-03-10

    Microchannel apparatus comprising a header and plural flow microchannels is described in which orifices connect the header and the flow microchannels. The orifices constrict flow. The ratio of the cross-sectional area of each of the orifices to the cross-sectional area of the flow microchannels connected to the orifices is between 0.0005 and 0.1. Also described is microchannel apparatus for conducting unit operations in which a device comprises two arrays of microchannels, and a unit operation is conducted on a fluid as it passes through the first set of microchannels and into a header where a second unit operation is performed, and then the fluid stream passes into the second array of microchannels where the first unit operation is again performed. Methods of conducting unit operations in the apparatuses are also described.

  18. A construction and a tension element comprising a cable and one or more strakes

    DEFF Research Database (Denmark)

    2014-01-01

    The invention provides a construction comprising a structural element and at least one cable (101) arranged in tension to carry at least a part of the weight of the structural element. The cable defines an outer surface (102) onto which at least one strake (104) forms a protrusion for reducing rain...... and wind induced vibrations. The strake has a height being a distance from a strake root part connected to the outer surface of the cable and a strake end part terminating the strake outwards away from the cable, and the strake has a width being transverse to the height, the width decreasing...... in the direction from the strake root part towards the strake end part. The height is less than 5 percent of the diameter of the cable. Furthermore, the strake comprises a first strake surface portion facing away from the cable, which first strake surface portion is concave or straight....

  19. Energy storage systems having an electrode comprising Li.sub.xS.sub.y

    Science.gov (United States)

    Xiao, Jie; Zhang, Jiguang; Graff, Gordon L.; Liu, Jun; Wang, Wei; Zheng, Jianming; Xu, Wu; Shao, Yuyan; Yang, Zhenguo

    2016-08-02

    Improved lithium-sulfur energy storage systems can utilizes Li.sub.xS.sub.y as a component in an electrode of the system. For example, the energy storage system can include a first electrode current collector, a second electrode current collector, and an ion-permeable separator separating the first and second electrode current collectors. A second electrode is arranged between the second electrode current collector and the separator. A first electrode is arranged between the first electrode current collector and the separator and comprises a first condensed-phase fluid comprising Li.sub.xS.sub.y. The energy storage system can be arranged such that the first electrode functions as a positive or a negative electrode.

  20. DC high voltage to drive helium plasma jet comprised of repetitive streamer breakdowns

    CERN Document Server

    Wang, Xingxing

    2016-01-01

    This paper demonstrates and studies helium atmospheric pressure plasma jet comprised of series of repetitive streamer breakdowns, which is driven by a pure DC high voltage (auto-oscillations). Repetition frequency of the breakdowns is governed by the geometry of discharge electrodes/surroundings and gas flow rate. Each next streamer is initiated when the electric field on the anode tip recovers after the previous breakdown and reaches the breakdown threshold value of about 2.5 kV/cm. Repetition frequency of the streamer breakdowns excited using this principle can be simply tuned by reconfiguring the discharge electrode geometry. This custom-designed type of the helium plasma jet, which operates on the DC high voltage and is comprised of the series of the repetitive streamer breakdowns at frequency about 13 kHz, is demonstrated.

  1. Lateral acoustic wave resonator comprising a suspended membrane of low damping resonator material

    Science.gov (United States)

    Olsson, Roy H.; El-Kady; , Ihab F.; Ziaei-Moayyed, Maryam; Branch; , Darren W.; Su; Mehmet F.,; Reinke; Charles M.,

    2013-09-03

    A very high-Q, low insertion loss resonator can be achieved by storing many overtone cycles of a lateral acoustic wave (i.e., Lamb wave) in a lithographically defined suspended membrane comprising a low damping resonator material, such as silicon carbide. The high-Q resonator can sets up a Fabry-Perot cavity in a low-damping resonator material using high-reflectivity acoustic end mirrors, which can comprise phononic crystals. The lateral overtone acoustic wave resonator can be electrically transduced by piezoelectric couplers. The resonator Q can be increased without increasing the impedance or insertion loss by storing many cycles or wavelengths in the high-Q resonator material, with much lower damping than the piezoelectric transducer material.

  2. Challenges in marine instrumentation

    Digital Repository Service at National Institute of Oceanography (India)

    Afzulpurkar, S.; Desa, E.; Joseph, A.; Chakraborty, B.; Nayak, M.R.; Ranade, G.

    . Acoustic and optical instrumentation combined on the same platform would be able to address these problems. For this autonomous vehicles with extremely low power requirements, long term deployment and data transmission capability via satellites after...

  3. UV and EUV Instruments

    CERN Document Server

    Werner, K

    2010-01-01

    We describe telescopes and instruments that were developed and used for astronomical research in the ultraviolet (UV) and extreme ultraviolet (EUV) regions of the electromagnetic spectrum. The wavelength ranges covered by these bands are not uniquely defined. We use the following convention here: The EUV and UV span the regions ~100-912 and 912-3000 Angstroem respectively. The limitation between both ranges is a natural choice, because the hydrogen Lyman absorption edge is located at 912 Angstroem. At smaller wavelengths, astronomical sources are strongly absorbed by the interstellar medium. It also marks a technical limit, because telescopes and instruments are of different design. In the EUV range, the technology is strongly related to that utilized in X-ray astronomy, while in the UV range the instruments in many cases have their roots in optical astronomy. We will, therefore, describe the UV and EUV instruments in appropriate conciseness and refer to the respective chapters of this volume for more technic...

  4. Fiber Optics Instrumentation Development

    Science.gov (United States)

    Chan, Patrick Hon Man; Parker, Allen R., Jr.; Richards, W. Lance

    2010-01-01

    This is a general presentation of fiber optics instrumentation development work being conducted at NASA Dryden for the past 10 years and recent achievements in the field of fiber optics strain sensors.

  5. Instrumentation for Materials Research

    Science.gov (United States)

    Claassen, Richard S.

    1976-01-01

    Discusses how sophisticated instrumentation techniques yield practical results in three typical materials problems: fracture analysis, joining, and compatibility. Describes techniques such as scanning and transmission electron microscopy, and Auger spectroscopy. (MLH)

  6. Orifice plate for controlling solids flow, methods of use thereof and articles comprising the same

    Energy Technology Data Exchange (ETDEWEB)

    Jukkola, Glen D.; Teigen, Bard C.

    2017-01-31

    Disclosed herein is an orifice plate comprising one or more plates having orifices disposed therein; the orifices being operative to permit the flow of solids from a moving bed heat exchanger to a solids flow control system; where the orifice plate is downstream of a tube bundle of the moving bed heat exchanger and upstream of the solids flow control system and wherein the orifice plate is operative to evenly distribute the flow of solids in the solids flow control system.

  7. Transgenic Carrot Expressing Fusion Protein Comprising M. tuberculosis Antigens Induces Immune Response in Mice

    OpenAIRE

    Natalia V. Permyakova; Zagorskaya, Alla A.; Belavin, Pavel A.; Elena A. Uvarova; Nosareva, Olesya V.; Nesterov, Andrey E.; Novikovskaya, Anna A.; Evgeniy L. Zav’yalov; Mikhail P Moshkin; Deineko, Elena V.

    2015-01-01

    Tuberculosis remains one of the major infectious diseases, which continues to pose a major global health problem. Transgenic plants may serve as bioreactors to produce heterologous proteins including antibodies, antigens, and hormones. In the present study, a genetic construct has been designed that comprises the Mycobacterium tuberculosis genes cfp10, esat6 and dIFN gene, which encode deltaferon, a recombinant analog of the human γ-interferon designed for expression in plant tissues. This co...

  8. VIRUS instrument collimator assembly

    Science.gov (United States)

    Marshall, Jennifer L.; DePoy, Darren L.; Prochaska, Travis; Allen, Richard D.; Williams, Patrick; Rheault, Jean-Philippe; Li, Ting; Nagasawa, Daniel Q.; Akers, Christopher; Baker, David; Boster, Emily; Campbell, Caitlin; Cook, Erika; Elder, Alison; Gary, Alex; Glover, Joseph; James, Michael; Martin, Emily; Meador, Will; Mondrik, Nicholas; Rodriguez-Patino, Marisela; Villanueva, Steven; Hill, Gary J.; Tuttle, Sarah; Vattiat, Brian; Lee, Hanshin; Chonis, Taylor S.; Dalton, Gavin B.; Tacon, Mike

    2014-07-01

    The Visual Integral-Field Replicable Unit Spectrograph (VIRUS) instrument is a baseline array 150 identical fiber fed optical spectrographs designed to support observations for the Hobby-Eberly Telescope Dark Energy Experiment (HETDEX). The collimator subassemblies of the instrument have been assembled in a production line and are now complete. Here we review the design choices and assembly practices used to produce a suite of identical low-cost spectrographs in a timely fashion using primarily unskilled labor.

  9. Modeling of Musical Instruments

    Science.gov (United States)

    Bader, Rolf; Hansen, Uwe

    Signal processing techniques in acoustics address many concerns. Included are such things as wave propagation variables, amplitude considerations, spectral content, wavelength, and phase. Phase is primarily of concern when waves interact with each other, as well as with a medium, and the imposition of boundary conditions leads to normal mode vibrations. Such conditions are prevalent in all musical instruments, and thus relevant signal processing techniques are essential to both understanding and modeling the structure of musical instruments and the sound radiated.

  10. A reconfigurable on-line learning spiking neuromorphic processor comprising 256 neurons and 128K synapses.

    Science.gov (United States)

    Qiao, Ning; Mostafa, Hesham; Corradi, Federico; Osswald, Marc; Stefanini, Fabio; Sumislawska, Dora; Indiveri, Giacomo

    2015-01-01

    Implementing compact, low-power artificial neural processing systems with real-time on-line learning abilities is still an open challenge. In this paper we present a full-custom mixed-signal VLSI device with neuromorphic learning circuits that emulate the biophysics of real spiking neurons and dynamic synapses for exploring the properties of computational neuroscience models and for building brain-inspired computing systems. The proposed architecture allows the on-chip configuration of a wide range of network connectivities, including recurrent and deep networks, with short-term and long-term plasticity. The device comprises 128 K analog synapse and 256 neuron circuits with biologically plausible dynamics and bi-stable spike-based plasticity mechanisms that endow it with on-line learning abilities. In addition to the analog circuits, the device comprises also asynchronous digital logic circuits for setting different synapse and neuron properties as well as different network configurations. This prototype device, fabricated using a 180 nm 1P6M CMOS process, occupies an area of 51.4 mm(2), and consumes approximately 4 mW for typical experiments, for example involving attractor networks. Here we describe the details of the overall architecture and of the individual circuits and present experimental results that showcase its potential. By supporting a wide range of cortical-like computational modules comprising plasticity mechanisms, this device will enable the realization of intelligent autonomous systems with on-line learning capabilities.

  11. Alcohol dose dumping: The influence of ethanol on hot-melt extruded pellets comprising solid lipids.

    Science.gov (United States)

    Jedinger, N; Schrank, S; Mohr, S; Feichtinger, A; Khinast, J; Roblegg, E

    2015-05-01

    The objective of the present study was to investigate interactions between alcohol and hot-melt extruded pellets and the resulting drug release behavior. The pellets were composed of vegetable calcium stearate as matrix carrier and paracetamol or codeine phosphate as model drugs. Two solid lipids (Compritol® and Precirol®) were incorporated into the matrix to form robust/compact pellets. The drug release characteristics were a strong function of the API solubility, the addition of solid lipids, the dissolution media composition (i.e., alcohol concentration) and correspondingly, the pellet wettability. Pellets comprising paracetamol, which is highly soluble in ethanol, showed alcohol dose dumping regardless of the matrix composition. The wettability increased with increasing ethanol concentrations due to higher paracetamol solubilities yielding increased dissolution rates. For pellets containing codeine phosphate, which has a lower solubility in ethanol than in acidic media, the wettability was a function of the matrix composition. Dose dumping occurred for formulations comprising solid lipids as they showed increased wettabilities with increasing ethanol concentrations. In contrast, pellets comprising calcium stearate as single matrix component showed robustness in alcoholic media due to wettabilities that were not affected by the addition of ethanol. The results clearly indicate that the physico-chemical properties of the drug and the matrix systems are crucial for the design of ethanol-resistant dosage forms. Moreover, hydrophobic calcium stearate can be considered a suitable matrix system that minimizes the risk of ethanol-induced dose dumping for certain API's.

  12. Assessing an organizational culture instrument based on the Competing Values Framework: Exploratory and confirmatory factor analyses

    Directory of Open Access Journals (Sweden)

    Mohr David C

    2007-04-01

    Full Text Available Abstract Background The Competing Values Framework (CVF has been widely used in health services research to assess organizational culture as a predictor of quality improvement implementation, employee and patient satisfaction, and team functioning, among other outcomes. CVF instruments generally are presented as well-validated with reliable aggregated subscales. However, only one study in the health sector has been conducted for the express purpose of validation, and that study population was limited to hospital managers from a single geographic locale. Methods We used exploratory and confirmatory factor analyses to examine the underlying structure of data from a CVF instrument. We analyzed cross-sectional data from a work environment survey conducted in the Veterans Health Administration (VHA. The study population comprised all staff in non-supervisory positions. The survey included 14 items adapted from a popular CVF instrument, which measures organizational culture according to four subscales: hierarchical, entrepreneurial, team, and rational. Results Data from 71,776 non-supervisory employees (approximate response rate 51% from 168 VHA facilities were used in this analysis. Internal consistency of the subscales was moderate to strong (α = 0.68 to 0.85. However, the entrepreneurial, team, and rational subscales had higher correlations across subscales than within, indicating poor divergent properties. Exploratory factor analysis revealed two factors, comprising the ten items from the entrepreneurial, team, and rational subscales loading on the first factor, and two items from the hierarchical subscale loading on the second factor, along with one item from the rational subscale that cross-loaded on both factors. Results from confirmatory factor analysis suggested that the two-subscale solution provides a more parsimonious fit to the data as compared to the original four-subscale model. Conclusion This study suggests that there may be problems

  13. MC and A instrumentation catalog

    Energy Technology Data Exchange (ETDEWEB)

    Neymotin, L. [ed.] [Brookhaven National Lab., Upton, NY (United States); Sviridova, V. [ed.] [All-Russian Research Inst. of Automatics, Moscow (Russian Federation)

    1998-06-01

    In 1981 and 1985, two editions of a catalog of non-destructive nuclear measurement instrumentation, and material control and surveillance equipment, were published by Brookhaven National Laboratory (BNL). The last edition of the catalog included one hundred and twenty-five entries covering a wide range of devices developed in the US and abroad. More than ten years have elapsed since the publication of the more recent Catalog. Devices described in it have undergone significant modifications, and new devices have been developed. Therefore, in order to assist specialists in the field of Material Control and Accounting (MC and A), a new catalog has been created. Work on this instrumentation catalog started in 1997 as a cooperative effort of Brookhaven National Laboratory (BNL), operated by Brookhaven Science Associates under contract to the US Department of Energy, and the All-Russian Research Institute of Automatics (VNIIA), subordinate institute of the Atomic Energy Ministry of the Russian Federation, within the collaborative US-Russia Material Protection, Control, and Accounting (MPC and A) Program. Most of the equipment included in the Catalog are non-destructive assay (NDA) measurement devices employed for purposes of accounting, confirmation, and verification of nuclear materials. Other devices also included in the Catalog are employed in the detection and deterrence of unauthorized access to or removal of nuclear materials (material control: containment and surveillance). Equipment found in the Catalog comprises either: (1) complete devices or systems that can be used for MC and A applications; or (2) parts or components of complete systems, such as multi-channel analyzers, detectors, neutron generators, and software. All devices are categorized by their status of development--from prototype to serial production.

  14. The Survey Questionnaire

    Science.gov (United States)

    Ritter, Lois A. Ed.; Sue, Valerie M., Ed.

    2007-01-01

    Internet-based surveys are still relatively new, and researchers are just beginning to articulate best practices for questionnaire design. Online questionnaire design has generally been guided by the principles applying to other self-administered instruments, such as paper-based questionnaires. Web-based questionnaires, however, have the potential…

  15. Increased Science Instrumentation Funding Strengthens Mars Program

    Science.gov (United States)

    Graham, Lee D.; Graff, T. G.

    2012-01-01

    As the strategic knowledge gaps mature for the exploration of Mars, Mars sample return (MSR), and Phobos/Deimos missions, one approach that becomes more probable involves smaller science instrumentation and integrated science suites. Recent technological advances provide the foundation for a significant evolution of instrumentation; however, the funding support is currently too small to fully utilize these advances. We propose that an increase in funding for instrumentation development occur in the near-term so that these foundational technologies can be applied. These instruments would directly address the significant knowledge gaps for humans to Mars orbit, humans to the Martian surface, and humans to Phobos/ Deimos. They would also address the topics covered by the Decadal Survey and the Mars scientific goals, objectives, investigations and priorities as stated by the MEPAG. We argue that an increase of science instrumentation funding would be of great benefit to the Mars program as well as the potential for human exploration of the Mars system. If the total non-Earth-related planetary science instrumentation budget were increased 100% it would not add an appreciable amount to the overall NASA budget and would provide the real potential for future breakthroughs. If such an approach were implemented in the near-term, NASA would benefit greatly in terms of science knowledge of the Mars, Phobos/Deimos system, exploration risk mitigation, technology development, and public interest.

  16. Plane and geodetic surveying

    CERN Document Server

    Johnson, Aylmer

    2014-01-01

    IntroductionAim And ScopeClassification Of SurveysThe Structure Of This BookGeneral Principles Of SurveyingErrorsRedundancyStiffnessAdjustmentPlanning And Record KeepingPrincipal Surveying ActivitiesEstablishing Control NetworksMappingSetting OutResectioningDeformation MonitoringAngle MeasurementThe Surveyor's CompassThe ClinometerThe Total StationMaking ObservationsChecks On Permanent AdjustmentsDistance MeasurementGeneralTape MeasurementsOptical Methods (Tachymetry)Electromagnetic Distance Measurement (EDM)Ultrasonic MethodsGNSSLevellingTheoryThe InstrumentTechniqueBookingPermanent Adjustmen

  17. Research and Development on a Public Attitude Instrument for Stuttering

    Science.gov (United States)

    St. Louis, Kenneth O.

    2012-01-01

    This paper summarizes research associated with the development of the "Public Opinion Survey of Human Attributes-Stuttering" ("POSHA-S"), a survey instrument designed to provide a worldwide standard measure of public attitudes toward stuttering. Pilot studies with early experimental prototypes of the "POSHA-S" are summarized that relate to…

  18. Research and Development on a Public Attitude Instrument for Stuttering

    Science.gov (United States)

    St. Louis, Kenneth O.

    2012-01-01

    This paper summarizes research associated with the development of the "Public Opinion Survey of Human Attributes-Stuttering" ("POSHA-S"), a survey instrument designed to provide a worldwide standard measure of public attitudes toward stuttering. Pilot studies with early experimental prototypes of the "POSHA-S" are summarized that relate to…

  19. Method of converting a carbon-comprising material, method of operating a fuel cell stack, and a fuel cell

    NARCIS (Netherlands)

    Hemmes, K.

    1999-01-01

    The invention relates to a method of converting a carbon-comprising material at elevated temperature in the presence of a molecule that comprises at least one oxygen atom. According to the invention the carbon-comprising material in the fuel cell is converted substantially to carbon monoxide in a re

  20. Method of converting a carbon-comprising material, method of operating a fuel cell stack, and a fuel cell

    NARCIS (Netherlands)

    Hemmes, K.

    1999-01-01

    The invention relates to a method of converting a carbon-comprising material at elevated temperature in the presence of a molecule that comprises at least one oxygen atom. According to the invention the carbon-comprising material in the fuel cell is converted substantially to carbon monoxide in a

  1. Towards an instrument targeting mobility-related participation

    DEFF Research Database (Denmark)

    Brandt, Ase; Löfqvist, Charlotte; Jónsdottir, Inga

    2008-01-01

    OBJECTIVE: To investigate test-retest reliability and internal consistency of a new instrument for evaluation of mobility device interventions. MATERIAL AND METHODS: The instrument comprised 4 scales and one summed index. Two test-retest interviews involved 147 mobility device users (mean age 60......-retest reliability of all but one of the scales of the new instrument was substantial to almost perfect, this study demonstrated that revision is required. The challenges identified were probably due to the highly complex relationship between outdoor participation while using mobility devices and accessibility...... to the outdoor physical environment. Thus, based on the results of this study the instrument will be revised and subsequently launched as the "Nordic mobility-related participation outcome evaluation of assistive device intervention" (NOMO instrument). More research on the concept of mobility...

  2. Construct distinctiveness and variance composition of multi-dimensional instruments: Three short-form masculinity measures.

    Science.gov (United States)

    Levant, Ronald F; Hall, Rosalie J; Weigold, Ingrid K; McCurdy, Eric R

    2015-07-01

    Focusing on a set of 3 multidimensional measures of conceptually related but different aspects of masculinity, we use factor analytic techniques to address 2 issues: (a) whether psychological constructs that are theoretically distinct but require fairly subtle discriminations by survey respondents can be accurately captured by self-report measures, and (b) how to better understand sources of variance in subscale and total scores developed from such measures. The specific measures investigated were the: (a) Male Role Norms Inventory-Short Form (MRNI-SF); (b) Conformity to Masculine Norms Inventory-46 (CMNI-46); and (c) Gender Role Conflict Scale-Short Form (GRCS-SF). Data (N = 444) were from community-dwelling and college men who responded to an online survey. EFA results demonstrated the discriminant validity of the 20 subscales comprising the 3 instruments, thus indicating that relatively subtle distinctions between norms, conformity, and conflict can be captured with self-report measures. CFA was used to compare 2 different methods of modeling a broad/general factor for each of the 3 instruments. For the CMNI-46 and MRNI-SF, a bifactor model fit the data significantly better than did a hierarchical factor model. In contrast, the hierarchical model fit better for the GRCS-SF. The discussion addresses implications of these specific findings for use of the measures in research studies, as well as broader implications for measurement development and assessment in other research domains of counseling psychology which also rely on multidimensional self-report instruments. (c) 2015 APA, all rights reserved).

  3. The keyboard instruments.

    Science.gov (United States)

    Manchester, Ralph A

    2014-06-01

    Now that the field of performing arts medicine has been in existence for over three decades, we are approaching a key point: we should start to see more articles that bring together the data that have been collected from several studies in order to draw more robust conclusions. Review articles and their more structured relative, the meta-analysis, can help to improve our understanding of a particular topic, comparing and synthesizing the results of previous research that has been done on that subject area. One way this could be done would be to review the research that has been carried out on the performance-related problems associated with playing a particular instrument or group of instruments. While I am not going to do that myself, I hope that others will. In this editorial, I will do a very selective review of the playing-related musculoskeletal disorders (PRMDs) associated with one instrument group (the keyboard instruments), focusing on the most played instrument in that group (the piano;).

  4. Cobalamin status during normal pregnancy and postpartum: a longitudinal study comprising 406 danish women

    DEFF Research Database (Denmark)

    Milman, N; Byg, KE; Bergholt, T

    2006-01-01

    OBJECTIVES: To assess cobalamin (vitamin B(12)) status during normal pregnancy and postpartum in a longitudinal setting. METHODS: This study was performed in 1995-1996. It comprised 406 healthy, pregnant Danish Caucasian women, living in Copenhagen County. Cobalamin status, i.e. plasma (P...... in late pregnancy. The recommendations for periconceptional vitamin B(12) supplementation should be reconsidered.......-) cobalamin, P-methylmalonic acid and P-homocysteine was measured at 18, 32 and 39 wk gestation and 8 wk postpartum during lactation. RESULTS: P-cobalamin showed a gradual, significant decline during pregnancy (P

  5. Composites comprising novel RTIL-based polymers, and methods of making and using same

    Energy Technology Data Exchange (ETDEWEB)

    Gin, Douglas; Carlisle, Trevor; Noble, Richard; Nicodemus, Garret; McDanel, William; Cowan, Matthew

    2017-06-27

    The invention includes compositions comprising curable imidazolium-functionalized poly(room-temperature ionic liquid) copolymers and homopolymers. The invention further includes methods of preparing and using the compositions of the invention. The invention further includes novel methods of preparing thin, supported, room-temperature ionic liquid-containing polymeric films on a porous support. In certain embodiments, the methods of the invention avoid the use of a gutter layer, which greatly reduces the overall gas permeance and selectivity of the composite membrane. In other embodiments, the films of the invention have increased gas selectivity and permeance over films prepared using methods described in the prior art.

  6. The Electrical Properties for Phenolic Isocyanate-Modified Bisphenol-Based Epoxy Resins Comprising Benzoate Group.

    Science.gov (United States)

    Lee, Eun Yong; Chae, Il Seok; Park, Dongkyung; Suh, Hongsuk; Kang, Sang Wook

    2016-03-01

    Epoxy resin has been required to have a low dielectric constant (D(k)), low dissipation factor (Df), low coefficient of thermal expansion (CTE), low water absorption, high mechanical, and high adhesion properties for various applications. A series of novel phenolic isocyanate-modified bisphenol-based epoxy resins comprising benzoate group were prepared for practical electronic packaging applications. The developed epoxy resins showed highly reduced dielectric constants (D(k)-3.00 at 1 GHz) and low dissipation values (Df-0.014 at 1 GHz) as well as enhanced thermal properties.

  7. Quantum correlations and entanglement in a model comprised of a short chain of nonlinear oscillators

    Science.gov (United States)

    Kalaga, J. K.; Kowalewska-Kudłaszyk, A.; Leoński, W.; Barasiński, A.

    2016-09-01

    We discuss a model comprised of a chain of three Kerr-like nonlinear oscillators pumped by two modes of external coherent field. We show that the system can be treated as nonlinear quantum scissors and behave as a three-qubit model. For such situation, different types of tripartite entangled states can be generated, even when damping effects are present in the system. Some amount of such entanglement can survive even in a long-time limit. The flow of bipartite entanglement between subsystems of the model and relations among first-order correlations, second-order correlations, and the entanglement are discussed.

  8. IDIOMS THAT COMPRISE THE PRESENCE OF TURKISH WORDS IN GREEK CYPRIOT LANGUAGE

    OpenAIRE

    Şevket ÖZNUR; Mahmut İSLÂMOĞLU

    2010-01-01

    In this communiqué again we preferred to present some examples from the effects of Turkish Cypriot Culture. For a few years, we have concentrated on our culture’s effect on other cultures in Cyprus. Bearing in mind that we have lived together for hundreds of years with other societies, we have seen fit to give examples of the cultural interaction between other cultures and Turkish Cypriot culture. Our communiqué mostly comprises the effects of Turkish Culture. We have found it convenient to p...

  9. Structures and Energetic Properties of Two New Salts Comprising the 5,5'-Azotetrazolate Dianion

    Directory of Open Access Journals (Sweden)

    Raik Deblitz

    2015-09-01

    Full Text Available Two new potentially energetic salts comprising the 5,5'-azotetrazolate dianion have been prepared and structurally characterized. The new azotetrazolates are tetraphenylphosphonium-5,5'-azotetrazolate (1 and 1H-1,2,4-triazole-1-carboxamidine-5,5'-azotetrazolate (2. The crystal structures of both compounds have been determined by single-crystal X-ray diffraction and their energetic properties have been tested. Due to its high nitrogen-content of 73.14%, compound 2 was found to be significantly impact-sensitive.

  10. HVDC Solution for Offshore Wind Park Comprising Turbines Equipped with Full-Range Converters

    DEFF Research Database (Denmark)

    Sharma, Ranjan; Rasmussen, Tonny Wederberg; Jensen, Kim Høj

    2010-01-01

    of a HVDC transmission system. The power system under study includes an offshore wind farm comprising turbines equipped with full range converters. The collection network is a local AC grid. Power transmission is done through HVDC system. The grid side VSC (voltage source converter) controls the DC voltage...... a voltage drop is created at the collection grid, the wind turbines go into fault-ride-through mode. The power output from each of the wind turbines is thus reduced to balance the system power. The detailed explanation of the strategy is presented in the paper. Matlab simulation model was prepared and some...

  11. Magnetoresistive sensors for string instruments

    Science.gov (United States)

    Lenssen, K.-M. H.; Somers, G. H. J.; van Zon, J. B. A. D.

    2002-05-01

    Pickup elements for string instruments, in particular for electric guitars, represent a new application area for magnetoresistive sensors. Recently we developed a sensor configuration with permanent magnets for this purpose. For the first experiments we used commercial anisotropic magnetoresistance sensors (Philips KMZ10) mounted on small ferrite bias magnets. Recently we equipped an electric guitar with prototypes comprising giant magnetoresistance (GMR) sensors. These prototype MR pickup elements showed several clear advantages compared to the presently commonly used inductive pickup units. They are much less sensitive to disturbing electromagnetic fields (>1000×at 5 kHz), mainly because their active sensor area is several orders of magnitude smaller (a few mm2 instead of cm2). Also the larger freedom in the choice of the permanent magnets (due to the larger sensitivity of the GMR elements) is advantageous: employing smaller magnets reduces the damping and thus significantly improves the sustain, the magnets can be less expensive and more stable magnet materials can be chosen so that aging effects are eliminated.

  12. A review of health-related workplace productivity loss instruments.

    Science.gov (United States)

    Lofland, Jennifer H; Pizzi, Laura; Frick, Kevin D

    2004-01-01

    The objective of this review was to identify health-related workplace productivity loss survey instruments, with particular emphasis on those that capture a metric suitable for direct translation into a monetary figure. A literature search using Medline, HealthSTAR, PsycINFO and Econlit databases between 1966 and 2002, and a telephone-administered survey of business leaders and researchers, were conducted to identify health-related workplace productivity measurement survey instruments. This review was conducted from the societal perspective. Each identified instrument was reviewed for the following: (i). reliability; (ii). content validity; (iii). construct validity; (iv). criterion validity; (v). productivity metric(s); (vi). instrument scoring technique; (vii). suitability for direct translation into a monetary figure; (viii). number of items; (ix). mode(s) of administration; and (x). disease state(s) in which it had been tested. Reliability and validity testing have been performed for 8 of the 11 identified surveys. Of the 11 instruments identified, six captured metrics that are suitable for direct translation into a monetary figure. Of those six, one instrument measured absenteeism, while the other five measured both absenteeism and presenteeism. All of the identified instruments except for one were available as paper, self-administered questionnaires and many were available in languages other than English. This review provides a comprehensive overview of the published, peer-reviewed survey instruments available to measure health-related workplace productivity loss. As the field of productivity measurement matures, tools may be developed that will allow researchers to accurately calculate lost productivity costs when performing cost-effectiveness and cost-benefit analyses. Using data captured by these instruments, society and healthcare decision makers will be able to make better informed decisions concerning the value of the medications, disease management and

  13. Biochemistry Instrumentation Core Technology Center

    Data.gov (United States)

    Federal Laboratory Consortium — The UCLA-DOE Biochemistry Instrumentation Core Facility provides the UCLA biochemistry community with easy access to sophisticated instrumentation for a wide variety...

  14. Heat Flux Instrumentation Laboratory (HFIL)

    Data.gov (United States)

    Federal Laboratory Consortium — Description: The Heat Flux Instrumentation Laboratory is used to develop advanced, flexible, thin film gauge instrumentation for the Air Force Research Laboratory....

  15. ONLINE INSTRUMENTS IN QUANTITATIVE MARKETING RESEARCH

    OpenAIRE

    STOICA, Ivona

    2011-01-01

    The Internet has brought great benefits, revolutionizing the world of marketing instruments used for advertising, bringing new areas such as search engine marketing, online marketing research, is a mediator of diverse individuals gathered in communities where borders no longer matter, and information is immeasurable. The impact of Internet use in marketing research refers to collecting data through online quantitative survey. This paper has its duty to reveal the importance of online cantitat...

  16. Aethalometer™ Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Sedlacek, Arthur J [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-04-01

    The Aethalometer is an instrument that provides a real-time readout of the concentration of “Black” or “Elemental” carbon aerosol particles (BC or E) in an air stream (see Figure 1 and Figure 2). It is a self-contained instrument that measures the rate of change of optical transmission through a spot on a filter where aerosol is being continuously collected and uses the information to calculate the concentration of optically absorbing material in the sampled air stream. The instrument measures the transmitted light intensities through the “sensing” portion of the filter, on which the aerosol spot is being collected, and a “reference” portion of the filter as a check on the stability of the optical source. A mass flowmeter monitors the sample air flow rate. The data from these three measurements is used to determine the mean BC content of the air stream.

  17. 3D Spectroscopic Instrumentation

    CERN Document Server

    Bershady, Matthew A

    2009-01-01

    In this Chapter we review the challenges of, and opportunities for, 3D spectroscopy, and how these have lead to new and different approaches to sampling astronomical information. We describe and categorize existing instruments on 4m and 10m telescopes. Our primary focus is on grating-dispersed spectrographs. We discuss how to optimize dispersive elements, such as VPH gratings, to achieve adequate spectral resolution, high throughput, and efficient data packing to maximize spatial sampling for 3D spectroscopy. We review and compare the various coupling methods that make these spectrographs ``3D,'' including fibers, lenslets, slicers, and filtered multi-slits. We also describe Fabry-Perot and spatial-heterodyne interferometers, pointing out their advantages as field-widened systems relative to conventional, grating-dispersed spectrographs. We explore the parameter space all these instruments sample, highlighting regimes open for exploitation. Present instruments provide a foil for future development. We give an...

  18. Micro mushroom instrumentation system

    Science.gov (United States)

    Davidson, W. F.

    1986-01-01

    An electronics circuit which provides for the recording of instrumentation data on an optical disk is disclosed. The optical disk is formatted in a spiral format instead of concentric tracks. The spiral format allows data to be recorded without the gaps that would be associated with concentric tracks. The instrumentation system provides each channel with a program instrumentation amplifier, a six pole lowpass switched capacitor filter, a sample and hold amplifier, and a digital to analog converter to provide automatic offset capability. Since each channel has its own components, simultaneous samples of every channel can be captured. All of the input signal's channel variables can be captured. All of the input signal's channel variables can be changed under software control without hardware changes. A single board computer is used for a system controller.

  19. ISSUERS OF FINANCIAL INSTRUMENTS

    Directory of Open Access Journals (Sweden)

    Cristian GHEORGHE

    2016-05-01

    Full Text Available The rules laid down by Romanian Capital Market Law and the regulations put in force for its implementation apply to issuers of financial instruments admitted to trading on the regulated market established in Romania. But the issuers remain companies incorporated under Company Law of 1990. Such dual regulations need increased attention in order to observe the legal status of the issuers/companies and financial instruments/shares. Romanian legislator has chosen to implement in Capital Market Law special rules regarding the administration of the issuers of financial instruments, not only rules regarding admitting and maintaining to a regulated market. Thus issuers are, in Romanian Law perspective, special company that should comply special rule regarding board of administration and general shareholders meeting.

  20. Calibration of Geodetic Instruments

    Directory of Open Access Journals (Sweden)

    Marek Bajtala

    2005-06-01

    Full Text Available The problem of metrology and security systems of unification, correctness and standard reproducibilities belong to the preferred requirements of theory and technical practice in geodesy. Requirements on the control and verification of measured instruments and equipments increase and the importance and up-to-date of calibration get into the foreground. Calibration possibilities of length-scales (of electronic rangefinders and angle-scales (of horizontal circles of geodetic instruments. Calibration of electronic rangefinders on the linear comparative baseline in terrain. Primary standard of planar angle – optical traverse and its exploitation for calibration of the horizontal circles of theodolites. The calibration equipment of the Institute of Slovak Metrology in Bratislava. The Calibration process and results from the calibration of horizontal circles of selected geodetic instruments.

  1. Virtual Sensor Test Instrumentation

    Science.gov (United States)

    Wang, Roy

    2011-01-01

    Virtual Sensor Test Instrumentation is based on the concept of smart sensor technology for testing with intelligence needed to perform sell-diagnosis of health, and to participate in a hierarchy of health determination at sensor, process, and system levels. A virtual sensor test instrumentation consists of five elements: (1) a common sensor interface, (2) microprocessor, (3) wireless interface, (4) signal conditioning and ADC/DAC (analog-to-digital conversion/ digital-to-analog conversion), and (5) onboard EEPROM (electrically erasable programmable read-only memory) for metadata storage and executable software to create powerful, scalable, reconfigurable, and reliable embedded and distributed test instruments. In order to maximize the efficient data conversion through the smart sensor node, plug-and-play functionality is required to interface with traditional sensors to enhance their identity and capabilities for data processing and communications. Virtual sensor test instrumentation can be accessible wirelessly via a Network Capable Application Processor (NCAP) or a Smart Transducer Interlace Module (STIM) that may be managed under real-time rule engines for mission-critical applications. The transducer senses the physical quantity being measured and converts it into an electrical signal. The signal is fed to an A/D converter, and is ready for use by the processor to execute functional transformation based on the sensor characteristics stored in a Transducer Electronic Data Sheet (TEDS). Virtual sensor test instrumentation is built upon an open-system architecture with standardized protocol modules/stacks to interface with industry standards and commonly used software. One major benefit for deploying the virtual sensor test instrumentation is the ability, through a plug-and-play common interface, to convert raw sensor data in either analog or digital form, to an IEEE 1451 standard-based smart sensor, which has instructions to program sensors for a wide variety of

  2. The DESI Experiment Part II: Instrument Design

    CERN Document Server

    Aghamousa, Amir; Ahlen, Steve; Alam, Shadab; Allen, Lori E; Prieto, Carlos Allende; Annis, James; Bailey, Stephen; Balland, Christophe; Ballester, Otger; Baltay, Charles; Beaufore, Lucas; Bebek, Chris; Beers, Timothy C; Bell, Eric F; Bernal, José Luis; Besuner, Robert; Beutler, Florian; Blake, Chris; Bleuler, Hannes; Blomqvist, Michael; Blum, Robert; Bolton, Adam S; Briceno, Cesar; Buckley-Geer, Elizabeth; Burden, Angela; Burtin, Etienne; Busca, Nicolas G; Cahn, Robert N; Cai, Yan-Chuan; Carlberg, Raymond G; Carton, Pierre-Henri; Casas, Ricard; Castander, Francisco J; Claybaugh, Todd M; Close, Madeline; Coker, Carl T; Cole, Shaun; Cooper, Andrew P; Cousinou, M -C; Crocce, Martin; Cuby, Jean-Gabriel; Cunningham, Daniel P; Davis, Tamara; Dawson, Kyle S; de la Macorra, Axel; De Vicente, Juan; Delubac, Timothée; Derwent, Mark; Dey, Arjun; Dhungana, Govinda; Ding, Zhejie; Duan, Yutong T; Ealet, Anne; Edelstein, Jerry; Eftekharzadeh, Sarah; Eisenstein, Daniel J; Elliott, Ann; Escoffier, Stephanie; Evatt, Matthew; Fagrelius, Parker; Fan, Xiaohui; Fanning, Kevin; Farahi, Arya; Favole, Ginevra; Feng, Yu; Fernandez, Enrique; Findlay, Joseph R; Finkbeiner, Douglas P; Fitzpatrick, Michael J; Flaugher, Brenna; Flender, Samuel; Font-Ribera, Andreu; Forero-Romero, Jaime E; Fosalba, Pablo; Frenk, Carlos S; Fumagalli, Michele; Garcia-Bellido, Juan; Gaztanaga, Enrique; Gershkovich, Irina; Gillet, Denis; Gonzalez-de-Rivera, Guillermo; Gonzalez-Perez, Violeta; Gott, Shelby; Graur, Or; Gutierrez, Gaston; Guy, Julien; Habib, Salman; Heetderks, Henry; Heetderks, Ian; Heitmann, Katrin; Hellwing, Wojciech A; Herrera, David A; Ho, Shirley; Honscheid, Klaus; Huff, Eric; Hutchinson, Timothy A; Huterer, Dragan; Hwang, Ho Seong; Laguna, Joseph Maria Illa; Ishikawa, Yuzo; Jacobs, Dianna; Jeffrey, Niall; Jelinsky, Patrick; Jiang, Linhua; Jimenez, Jorge; Johnson, Jennifer; Joyce, Richard; Jullo, Eric; Juneau, Stephanie; Kama, Sami; Karcher, Armin; Karkar, Sonia; Kehoe, Robert; Kennamer, Noble; Kent, Stephen; Kilbinger, Martin; Kim, Alex G; Kirkby, David; Kisner, Theodore; Kitanidis, Ellie; Kneib, Jean-Paul; Koposov, Sergey; Kovacs, Eve; Kremin, Anthony; Kron, Richard; Kronig, Luzius; Kueter-Young, Andrea; Lacey, Cedric G; Lafever, Robin; Lahav, Ofer; Lambert, Andrew; Landriau, Martin; Lang, Dustin; Name, Publication; Lauer, Tod R; Goff, Jean-Marc Le; Guillou, Laurent Le; Van Suu, Auguste Le; Lee, Jae Hyeon; Lee, Su-Jeong; Leitner, Daniela; Levi, Michael E; L'Huillier, Benjamin; Li, Baojiu; Liang, Ming; Lin, Huan; Linder, Eric; Loebman, Sarah R; Lukić, Zarija; MacCrann, Niall; Magneville, Christophe; Makarem, Laleh; Manera, Marc; Manser, Christopher J; Marshall, Robert; Martini, Paul; Massey, Richard; Matheson, Thomas; McCauley, Jeremy; McDonald, Patrick; McGreer, Ian D; Meisner, Aaron; Metcalfe, Nigel; Miller, Timothy N; Miquel, Ramon; Moustakas, John; Myers, Adam; Naik, Milind; Newman, Jeffrey; Nichol, Robert C; Nicola, Andrina; da Costa, Luiz Nicolati; Niz, Gustavo; Norberg, Peder; Nord, Brian; Norman, Dara; Nugent, Peter; O'Brien, Thomas; Oh, Minji; Olsen, Knut A G; Padilla, Cristobal; Padmanabhan, Hamsa; Padmanabhan, Nikhil; Palanque-Delabrouille, Nathalie; Palmese, Antonella; Pappalardo, Daniel; Park, Changbom; Patej, Anna; Peacock, John A; Peiris, Hiranya V; Percival, Will J; Perruchot, Sandrine; Pieri, Matthew M; Pogge, Richard; Poppett, Claire; Probst, Ronald G; Rabinowitz, David; Ree, Chang Hee; Refregier, Alexandre; Regal, Xavier; Reid, Beth; Reil, Kevin; Rezaie, Mehdi; Rockosi, Connie; Roe, Natalie; Ronayette, Samuel; Roodman, Aaron; Ross, Ashley J; Ross, Nicholas P; Rossi, Graziano; Rozo, Eduardo; Ruhlmann-Kleider, Vanina; Rykoff, Eli; Sabiu, Cristiano; Samushia, Lado; Sanchez, Javier; Schlegel, David J; Schneider, Michael; Schubnell, Michael; Secroun, Aurélia; Seljak, Uros; Seo, Hee-Jong; Serrano, Santiago; Shafieloo, Arman; Shan, Huanyuan; Sholl, Michael J; Shourt, William V; Silber, Joseph H; Silva, David R; Sirk, Martin M; Slosar, Anze; Smith, Alex; Smoot, George; Som, Debopam; Song, Yong-Seon; Sprayberry, David; Staten, Ryan; Stefanik, Andy; Tarle, Gregory; Tie, Suk Sien; Tinker, Jeremy L; Tojeiro, Rita; Valdes, Francisco; Valenzuela, Octavio; Valluri, Monica; Vargas-Magana, Mariana; Verde, Licia; Walker, Alistair R; Wang, Yuting; Weaver, Benjamin A; Weaverdyck, Curtis; Wechsler, Risa; Weinberg, David H; White, Martin; Yang, Qian; Yeche, Christophe; Zhao, Gong-Bo; Zheng, Yi; Zhu, Yaling; Zou, Hu; Zu, Ying

    2016-01-01

    DESI (Dark Energy Spectropic Instrument) is a Stage IV ground-based dark energy experiment that will study baryon acoustic oscillations and the growth of structure through redshift-space distortions with a wide-area galaxy and quasar redshift survey. The DESI instrument is a robotically-actuated, fiber-fed spectrograph capable of taking up to 5,000 simultaneous spectra over a wavelength range from 360 nm to 980 nm. The fibers feed ten three-arm spectrographs with resolution $R= \\lambda/\\Delta\\lambda$ between 2000 and 5500, depending on wavelength. The DESI instrument will be used to conduct a five-year survey designed to cover 14,000 deg$^2$. This powerful instrument will be installed at prime focus on the 4-m Mayall telescope in Kitt Peak, Arizona, along with a new optical corrector, which will provide a three-degree diameter field of view. The DESI collaboration will also deliver a spectroscopic pipeline and data management system to reduce and archive all data for eventual public use.

  3. The Dark Energy Spectroscopic Instrument (DESI): Data Systems

    Science.gov (United States)

    Bailey, Stephen; Bolton, Adam S.; Cahn, Robert N.; Dawson, Kyle; Forero Romero, Jaime; Guy, Julien; Kisner, Theodore; Moustakas, John; Nugent, Peter E.; Schlegel, David J.; Stark, Casey; Weaver, Benjamin; DESI Collaboration

    2015-01-01

    We present the design, status, and plans for the data systems of the Dark Energy Spectroscopic Instrument (DESI), a spectroscopic redshift survey of 25 million galaxies, quasars, and stars to be operated at the Kitt Peak National Observatory 4-m Mayall telescope from 2018-2023. DESI will obtain 5000 spectra (3600-9800 Å) per exposure using robotically positioned fibers. DESI data systems include the target selection pipeline, survey planning and operations, the spectroscopic data reduction pipeline, instrument simulations, and data transfer, archive, and distribution. While building on the heritage of previous galaxy redshift surveys, DESI is upgrading all aspects of the algorithms and pipelines to maximize the science reach of the new instrument and survey.

  4. Kiso Supernova Survey (KISS): Survey Strategy

    CERN Document Server

    Morokuma, Tomoki; Tanaka, Masaomi; Mori, Kensho; Matsumoto, Emiko; Kikuchi, Yuki; Shibata, Takumi; Sako, Shigeyuki; Aoki, Tsutomu; Doi, Mamoru; Kobayashi, Naoto; Maehara, Hiroyuki; Matsunaga, Noriyuki; Mito, Hiroyuki; Miyata, Takashi; Nakada, Yoshikazu; Soyano, Takao; Tarusawa, Ken'ichi; Miyazaki, Satoshi; Nakata, Fumiaki; Okada, Norio; Sarugaku, Yuki; Richmond, Michael W; Akitaya, Hiroshi; Aldering, Greg; Arimatsu, Ko; Contreras, Carlos; Horiuchi, Takashi; Hsiao, Eric Y; Itoh, Ryosuke; Iwata, Ikuru; Koji,; Kawabata, S; Kawai, Nobuyuki; Kitagawa, Yutaro; Kokubo, Mitsuru; Kuroda, Daisuke; Paolo,; Mazzali,; Misawa, Toru; Moritani, Yuki; Morrell, Nidia; Okamoto, Rina; Pavlyuk, Nikolay; Phillips, Mark M; Pian, Elena; Sahu, Devendra; Saito, Yoshihiko; Sano, Kei; Stritzinger, Maximilian D; Tachibana, Yutaro; Taddia, Francesco; Takaki, Katsutoshi; Tateuchi, Ken; Tomita, Akihiko; Tsvetkov, Dmitry; Ui, Takahiro; Ukita, Nobuharu; Urata, Yuji; Walker, Emma S; Yoshii, Taketoshi

    2014-01-01

    The Kiso Supernova Survey (KISS) is a high-cadence optical wide-field supernova (SN) survey. The primary goal of the survey is to catch the very early light of a SN, during the shock breakout phase. Detection of SN shock breakouts combined with multi-band photometry obtained with other facilities would provide detailed physical information on the progenitor stars of SNe. The survey is performed using a 2.2x2.2 deg field-of-view instrument on the 1.05-m Kiso Schmidt telescope, the Kiso Wide Field Camera (KWFC). We take a three-minute exposure in g-band once every hour in our survey, reaching magnitude g~20-21. About 100 nights of telescope time per year have been spent on the survey since April 2012. The number of the shock breakout detections is estimated to be of order of 1 during our 3-year project. This paper summarizes the KISS project including the KWFC observing setup, the survey strategy, the data reduction system, and CBET-reported SNe discovered so far by KISS.

  5. Kiso Supernova Survey (KISS): Survey strategy

    Science.gov (United States)

    Morokuma, Tomoki; Tominaga, Nozomu; Tanaka, Masaomi; Mori, Kensho; Matsumoto, Emiko; Kikuchi, Yuki; Shibata, Takumi; Sako, Shigeyuki; Aoki, Tsutomu; Doi, Mamoru; Kobayashi, Naoto; Maehara, Hiroyuki; Matsunaga, Noriyuki; Mito, Hiroyuki; Miyata, Takashi; Nakada, Yoshikazu; Soyano, Takao; Tarusawa, Ken'ichi; Miyazaki, Satoshi; Nakata, Fumiaki; Okada, Norio; Sarugaku, Yuki; Richmond, Michael W.; Akitaya, Hiroshi; Aldering, Greg; Arimatsu, Ko; Contreras, Carlos; Horiuchi, Takashi; Hsiao, Eric Y.; Itoh, Ryosuke; Iwata, Ikuru; Kawabata, Koji S.; Kawai, Nobuyuki; Kitagawa, Yutaro; Kokubo, Mitsuru; Kuroda, Daisuke; Mazzali, Paolo; Misawa, Toru; Moritani, Yuki; Morrell, Nidia; Okamoto, Rina; Pavlyuk, Nikolay; Phillips, Mark M.; Pian, Elena; Sahu, Devendra; Saito, Yoshihiko; Sano, Kei; Stritzinger, Maximilian D.; Tachibana, Yutaro; Taddia, Francesco; Takaki, Katsutoshi; Tateuchi, Ken; Tomita, Akihiko; Tsvetkov, Dmitry; Ui, Takahiro; Ukita, Nobuharu; Urata, Yuji; Walker, Emma S.; Yoshii, Taketoshi

    2014-12-01

    The Kiso Supernova Survey (KISS) is a high-cadence optical wide-field supernova (SN) survey. The primary goal of the survey is to catch the very early light of a SN, during the shock breakout phase. Detection of SN shock breakouts combined with multi-band photometry obtained with other facilities would provide detailed physical information on the progenitor stars of SNe. The survey is performed using a 2.2° × 2.2° field-of-view instrument on the 1.05-m Kiso Schmidt telescope, the Kiso Wide Field Camera (KWFC). We take a 3-min exposure in g-band once every hour in our survey, reaching magnitude g ˜ 20-21. About 100 nights of telescope time per year have been spent on the survey since 2012 April. The number of the shock breakout detections is estimated to be of the order of 1 during our three-year project. This paper summarizes the KISS project including the KWFC observing setup, the survey strategy, the data reduction system, and CBET-reported SNe discovered so far by KISS.

  6. Standard NIM instrumentation system

    CERN Document Server

    1990-01-01

    NIM is a standard modular instrumentation system that is in wide use throughout the world. As the NIM system developed and accommodations were made to a dynamic instrumentation field and a rapidly advancing technology, additions, revisions and clarifications were made. These were incorporated into the standard in the form of addenda and errata. This standard is a revision of the NIM document, AEC Report TID- 20893 (Rev 4) dated July 1974. It includes all the addenda and errata items that were previously issued as well as numerous additional items to make the standard current with modern technology and manufacturing practice.

  7. Animation of MARDI Instrument

    Science.gov (United States)

    2008-01-01

    [figure removed for brevity, see original site] Click on image to view the animation This animation shows a zoom into the Mars Descent Imager (MARDI) instrument onboard NASA's Phoenix Mars Lander. The Phoenix team will soon attempt to use a microphone on the MARDI instrument to capture sounds of Mars. The Phoenix Mission is led by the University of Arizona, Tucson, on behalf of NASA. Project management of the mission is by NASA's Jet Propulsion Laboratory, Pasadena, Calif. Spacecraft development is by Lockheed Martin Space Systems, Denver.

  8. Virtual Reality Musical Instruments

    DEFF Research Database (Denmark)

    Serafin, Stefania; Erkut, Cumhur; Kojs, Juraj

    2016-01-01

    The rapid development and availability of low-cost technologies have created a wide interest in virtual reality. In the field of computer music, the term “virtual musical instruments” has been used for a long time to describe software simulations, extensions of existing musical instruments......, and ways to control them with new interfaces for musical expression. Virtual reality musical instruments (VRMIs) that include a simulated visual component delivered via a head-mounted display or other forms of immersive visualization have not yet received much attention. In this article, we present a field...

  9. Spectroelectrochemical Instrument Measures TOC

    Science.gov (United States)

    Kounaves, Sam

    2011-01-01

    A spectroelectrochemical instrument has been developed for measuring the total organic carbon (TOC) content of an aqueous solution. Measurements of TOC are frequently performed in environmental, clinical, and industrial settings. Until now, techniques for performing such measurements have included, various ly, the use of hazardous reagents, ultraviolet light, or ovens, to promote reactions in which the carbon contents are oxidized. The instrument now being developed is intended to be a safer, more economical means of oxidizing organic carbon and determining the TOC levels of aqueous solutions and for providing a low power/mass unit for use in planetary missions.

  10. [Hardening of dental instruments].

    Science.gov (United States)

    Gerasev, G P

    1981-01-01

    The possibility of prolonging the service life of stomatological instruments by the local hardening of their working parts is discussed. Such hardening should be achieved by using hard and wear-resistant materials. The examples of hardening dental elevators and hard-alloy dental drills are given. New trends in the local hardening of instruments are the treatment of their working parts with laser beams, the application of coating on their surface by the gas-detonation method. The results of research work and trials are presented.

  11. Celadon Figurines Play Instruments

    Institute of Scientific and Technical Information of China (English)

    1995-01-01

    This group of figurines, each 0.15m tall, were unearthed from a Tang Dynasty tomb in Changsha in 1977. Music was very developed in the Tang Dynasty. Colorful musical instruments and dances were popular both among the people and in the palace. These vivid-looking figurines wear pleated skirts with small sleeves and open chest, a style influenced by the non-Han nationalities living in the north and west of China. Some of the musical instruments were brought from the Western Regions. The figurines are playing the xiao (a vertical bamboo flute), the konghou (an

  12. Virtual Reality Musical Instruments

    DEFF Research Database (Denmark)

    Serafin, Stefania; Erkut, Cumhur; Kojs, Juraj

    2016-01-01

    The rapid development and availability of low-cost technologies have created a wide interest in virtual reality. In the field of computer music, the term “virtual musical instruments” has been used for a long time to describe software simulations, extensions of existing musical instruments......, and ways to control them with new interfaces for musical expression. Virtual reality musical instruments (VRMIs) that include a simulated visual component delivered via a head-mounted display or other forms of immersive visualization have not yet received much attention. In this article, we present a field...

  13. Pigmentation Effect of Rice Bran Extracted Minerals Comprising Soluble Silicic Acids

    Directory of Open Access Journals (Sweden)

    Hyun-Jun Jang

    2016-01-01

    Full Text Available Our investigation focused on identifying melanogenesis effect of soluble minerals in rice bran ash extract (RBE which include orthosilicic acid (OSA. Melanocytes were apparently normal in terms of morphology. It was, however, shown that they were stressed a little in the RBE and OSA added media in aspect of LDH activity. Melanin synthesis and intracellular tyrosinase activity were increased by treatment of RBE which is similar to that of OSA. The Western blotting results showed that TRP-1, tyrosinase, and MITF expression levels were 2-3 times higher in the OSA and RBE groups compared to the control group which promoted melanin synthesis through CREB phosphorylation. Moreover, histology and immunohistochemistry were shown to have similar result to that of protein expression. As a result, minerals which comprise orthosilicic acid has the potential to promote melanogenesis and both RBE and OSA have similar cell viability, protein expression, and immunostaining results, suggesting that RBE comprises specific minerals which promote melanin synthesis through increasing of MITF and CREB phosphorylation. Therefore, RBE could be used as a novel therapeutic approach to combat melanin deficiency related diseases by stimulating melanocytes via its soluble Si and mineral components.

  14. Emergent ferroelectricity in disordered tri-color multilayer structure comprised of ferromagnetic manganites

    Science.gov (United States)

    Niu, Li-Wei; Chen, Chang-Le; Dong, Xiang-Lei; Xing, Hui; Luo, Bing-Cheng; Jin, Ke-Xin

    2016-10-01

    Multiferroic materials, showing the coexistence and coupling of ferroelectric and magnetic orders, are of great technological and fundamental importance. However, the limitation of single phase multiferroics with robust magnetization and polarization hinders the magnetoelectric effect from being applied practically. Magnetic frustration, which can induce ferroelectricity, gives rise to multiferroic behavior. In this paper, we attempt to construct an artificial magnetically frustrated structure comprised of manganites to induce ferroelectricity. A disordered stacking of manganites is expected to result in frustration at interfaces. We report here that a tri-color multilayer structure comprised of non-ferroelectric La0.9Ca0.1MnO3(A)/Pr0.85Ca0.15MnO3(B)/Pr0.85Sr0.15MnO3(C) layers with the disordered arrangement of ABC-ACB-CAB-CBA-BAC-BCA is prepared to form magnetoelectric multiferroics. The multilayer film exhibits evidence of ferroelectricity at room temperature, thus presenting a candidate for multiferroics. Project supported by the National Natural Science Foundation of China (Grant Nos. 61471301, 61078057, 51172183, 51402240, and 51471134), the Specialized Research Fund for the Doctoral Program of Higher Education, China (Grant No. 20126102110045), the Natural Science Foundation of Shaanxi Province, China (Grant No. 2015JQ5125), and the Fundamental Research Funds for the Central Universities, China (Grant No. 3102015ZY078).

  15. Residence time distribution for electrokinetic flow through a microchannel comprising a bundle of cylinders.

    Science.gov (United States)

    Hsu, Jyh-Ping; Ting, Chung-Chieh; Lee, Duu-Jong; Tseng, Shiojenn; Chen, Chur-Jen; Su, Ay

    2007-03-01

    The electrokinetic flow of an electrolyte solution through a microchannel that comprises a bundle of cylinders is investigated for the case of constant surface potential. The system under consideration is simulated by a unit cell model, and analytical expressions for the flow field and the corresponding residence time distribution under various conditions are derived. These results are readily applicable to the assessment of the performance of a microreactor such as that which comprises a bundle of optical fibers. Numerical simulations are conducted to investigate the influences of the key parameters, including the thickness of the double layer, the strength of the applied electric field, the magnitude of the applied pressure gradient, and the characteristic sizes of a microchannel, on the residence time distribution. We show that the following could result in a shorter residence time: thin double layer, strong applied electric field, large applied pressure gradient, and small number of cylinders. Based on the thickness of the double layer, criteria are proposed for whether the flow field can be treated as a laminar flow or as a plug flow, two basic limiting cases in reactor design.

  16. Storage fading of a commercial 18650 cell comprised with NMC/LMO cathode and graphite anode

    Science.gov (United States)

    Wu, She-huang; Lee, Po-Han

    2017-05-01

    In this study, the storage capacity fade of a commercial 18650 lithium ion cell comprised with a composite cathode of LiNi0.5Mn0.3Co0.2O2 (NMC) and Li1.1Mn1.9O4 (LMO) and graphite anode at various depths-of-discharge (DoDs) and temperatures have been investigated. The results manifest that the capacity fading is strongly affected by the storage temperature and becomes prominent as temperatures higher than 45 °C. Results of the incremental capacity analysis of the charging/discharging curves cycled at C/25 rate under 25 °C after cells been stored at various DoDs at 60 °C for various durations are used to reveal the factors of storage capacity fade of this commercial cell in company with the results of post-mortem studies on the electrodes harvested from the 12 month storage-aged cells with SEM, EDX, XPS, XRD, and electrode capacity retention study with those of a fresh commercial cell for comparison. The contributions of these factors are also estimated quantitatively. The losses of active electrode materials are the main reasons of the storage capacity fade of the commercial cell comprised with composite NMC/LMO cathode and graphite anode, while the loss of lithium inventory is less influential. The degradation of the electrodes and the loss the lithium inventory are strongly DoD dependent.

  17. Simulation of a Drivetrain of a Vehicle comprising Continuously Variable Transmission

    Directory of Open Access Journals (Sweden)

    Abhijeet Sanchawat

    2013-06-01

    Full Text Available With the constant hike in fuel prices on a day to day basis, maximum performance with minimum compromise on the front of fuel economy and emissions is highly desirable and expected from a vehicle’s drivetrain. In this context, a drivetrain comprising a Continuously Variable Transmission (CVT plays the role to the best extent possible. CVT facilitates a continuous change in gear ratiosbetween the driver and the driven shaft. CVTs are superior to automatic transmissions with a fixed number of gear ratios in that it offers greater acceleration and more efficient fuel economy.In this paper, we propose to model a drivetrain of a vehicle comprising CVT. A detailed mathematical model based on the geometry of the components has been formulated and also, equations of theirrespective motions representing their behaviour have been derived. Furthermore, a dynamic model of a drivetrain, using bond graph method, is prepared which captures the behaviour of the CVT during thetransient shift ratio condition and the complete simulation is implemented in MATLAB Simulink. The results substantiate the effect of mass of flyweights and spring constant of torsion springs on theperformance of CVT.

  18. Development of measurement apparatus for high resolution electrical surveys; Komitsudo denki tansa sokuteiki no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Moriuchi, H.; Matsuda, Y.; Shiokawa, Y. [Sumiko Consultants Co. Ltd., Tokyo (Japan); Uchino, Y. [Cosmic Co. Ltd., Tokyo (Japan)

    1996-05-01

    For the enforcement of the {rho}a-{rho}u survey method which is a type of high-density electrical survey, a multichannel resistivity measuring instrument has been developed. This instrument, in addition to the above, conducts resistivity tomography and various other kinds of high-density electrical survey. A potential produced by a low frequency rectangular current of 1Hz or lower outputted by the transmitter of this instrument is received and measured by the receiver connected to electrodes positioned at 100 or less locations. The receiver comprises a scanner that automatically switches from electrode to electrode, conditioner that processes signals, and controller. A transmitter of the standard design outputs a maximum voltage of 800V and maximum current of 2A, making a device suitable for probing 50 to several 100m-deep levels. The receiver is operated by a personal computer that the controller is provided with. The newly-developed apparatus succeeded in presenting high-precision images of the result of a {rho}a-{rho}u analysis for an apparent resistivity section and of the underground structure, verifying the high quality of the data collected by this apparatus. 10 refs., 5 figs., 1 tab.

  19. Economic Policy Instruments

    DEFF Research Database (Denmark)

    Klemmensen, Børge

    2007-01-01

    Økonomiske instrumenter begrundes med behovet for politiske indgreb, der muliggør internaliseringen af omkostningerne ved de miljøpåvirkninger, produktion and levevis afstedkommer, således at hensyntagen til miljøet bliver en del af virksomheders og husholdningers omkostninger og dermed en tilsky...

  20. The ozone monitoring instrument

    NARCIS (Netherlands)

    Levelt, P.F.; Oord, G.H.J. van den; Dobber, M.R.; Mälkki, A.; Visser, H.; Vries, J. de; Stammes, P.; Lundell, J.O.V.; Saari, H.

    2006-01-01

    The Ozone Monitoring Instrument (OMI) flies on the National Aeronautics and Space Adminsitration's Earth Observing System Aura satellite launched in July 2004. OMI is a ultraviolet/visible (UV/VIS) nadir solar backscatter spectrometer, which provides nearly global coverage in one day with a spatial

  1. Creating a Super Instrument

    DEFF Research Database (Denmark)

    Kallionpää, Maria; Gasselseder, Hans-Peter

    2015-01-01

    Thanks to the development of new technology, musical instruments are no more tied to their existing acoustic or technical limitations as almost all parameters can be augmented or modified in real time. An increasing number of composers, performers, and computer programmers have thus become intere...

  2. Neutron instrumentation for biology

    Energy Technology Data Exchange (ETDEWEB)

    Mason, S.A. [Institut Laue-Langevin, Grenoble (France)

    1994-12-31

    In the October 1994 round of proposals at the ILL, the external biology review sub- committee was asked to allocate neutron beam time to a wide range of experiments, on almost half the total number of scheduled neutron instruments: on 3 diffractometers, on 3 small angle scattering instruments, and on some 6 inelastic scattering spectrometers. In the 3.5 years since the temporary reactor shutdown, the ILL`s management structure has been optimized, budgets and staff have been trimmed, the ILL reactor has been re-built, and many of the instruments up-graded, many powerful (mainly Unix) workstations have been introduced, and the neighboring European Synchrotron Radiation Facility has established itself as the leading synchrotron radiation source and has started its official user program. The ILL reactor remains the world`s most intense dedicated neutron source. In this challenging context, it is of interest to review briefly the park of ILL instruments used to study the structure and energetics of small and large biological systems. A brief summary will be made of each class of experiments actually proposed in the latest ILL proposal round.

  3. Advanced instrumentation and teleoperation

    Energy Technology Data Exchange (ETDEWEB)

    Decreton, M

    1998-07-01

    SCK-CEN's advanced instrumentation and teleoperation project aims at evaluating the potential of a telerobotic approach in a nuclear environment and, in particular, the use of remote-perception systems. Main achievements in 1997 in the areas of R and D on radiation tolerance for remote sensing, optical fibres and optical-fibre sensors, and computer-aided teleoperation are reported.

  4. Economic Policy Instruments

    DEFF Research Database (Denmark)

    Klemmensen, Børge

    2007-01-01

    Økonomiske instrumenter begrundes med behovet for politiske indgreb, der muliggør internaliseringen af omkostningerne ved de miljøpåvirkninger, produktion and levevis afstedkommer, således at hensyntagen til miljøet bliver en del af virksomheders og husholdningers omkostninger og dermed en...

  5. Instrument for assaying radiation

    Energy Technology Data Exchange (ETDEWEB)

    Coleman, Jody Rustyn; Farfan, Eduardo B.

    2016-03-22

    An instrument for assaying radiation includes a flat panel detector having a first side opposed to a second side. A collimated aperture covers at least a portion of the first side of the flat panel detector. At least one of a display screen or a radiation shield may cover at least a portion of the second side of the flat panel detector.

  6. Integrating Nephelometer Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Uin, J. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-03-01

    The Integrating Nephelometer (Figure 1) is an instrument that measures aerosol light scattering. It measures aerosol optical scattering properties by detecting (with a wide angular integration – from 7 to 170°) the light scattered by the aerosol and subtracting the light scattered by the carrier gas, the instrument walls and the background noise in the detector (zeroing). Zeroing is typically performed for 5 minutes every day at midnight UTC. The scattered light is split into red (700 nm), green (550 nm), and blue (450 nm) wavelengths and captured by three photomultiplier tubes. The instrument can measure total scatter as well as backscatter only (from 90 to 170°) (Heintzenberg and Charlson 1996; Anderson et al. 1996; Anderson and Ogren 1998; TSI 3563 2015) At ARM (Atmospheric Radiation Measurement), two identical Nephelometers are usually run in series with a sample relative humidity (RH) conditioner between them. This is possible because Nephelometer sampling is non-destructive and the sample can be passed on to another instrument. The sample RH conditioner scans through multiple RH values in cycles, treating the sample. This kind of setup allows to study how aerosol particles’ light scattering properties are affected by humidification (Anderson et al. 1996). For historical reasons, the two Nephelometers in this setup are labeled “wet” and “dry”, with the “dry” Nephelometer usually being the one before the conditioner and sampling ambient air (the names are switched for the MAOS measurement site due to the high RH of the ambient air).

  7. Instruments of Transformative Governance

    DEFF Research Database (Denmark)

    Borrás, Susana

    production and distribution channels. PDPs aim at overcoming current market and government failures by pooling resources in the attempt to solve this global social challenge. Thus, PDPs are a case of instruments of transformative research and innovation, operating in a transnational governance context...

  8. The tropospheric monitoring instrument

    NARCIS (Netherlands)

    Voert, M.J. te; Brakel, R. van; Witvoet, G.

    2014-01-01

    Thermal and opto-mechanical design and analysis work has been done on the Tropospheric Monitoring Instrument (TROPOMI), a spectrometer on the Copernicus Sentinel 5 Precursor satellite. To verify compliance with the stringent opto-mechanical stability requirements, detailed thermal and thermo-mechani

  9. Virtual reality musical instruments

    DEFF Research Database (Denmark)

    Serafin, Stefania; Erkut, Cumhur; Kojs, Juraj

    2016-01-01

    The rapid development and availability of low cost technologies has created a wide interest in virtual reality (VR), but how to design and evaluate multisensory interactions in VR remains as a challenge. In this paper, we focus on virtual reality musical instruments, present an overview of our...

  10. The ozone monitoring instrument

    NARCIS (Netherlands)

    Levelt, P.F.; Oord, G.H.J. van den; Dobber, M.R.; Mälkki, A.; Visser, H.; Vries, J. de; Stammes, P.; Lundell, J.O.V.; Saari, H.

    2006-01-01

    The Ozone Monitoring Instrument (OMI) flies on the National Aeronautics and Space Adminsitration's Earth Observing System Aura satellite launched in July 2004. OMI is a ultraviolet/visible (UV/VIS) nadir solar backscatter spectrometer, which provides nearly global coverage in one day with a spatial

  11. Payment Instrument Characteristics

    DEFF Research Database (Denmark)

    Holst, Jacques; Kjeldsen, Martin; Hedman, Jonas

    2015-01-01

    payment innovations. Using the Repertory Grid technique to explore 15 payers’ perception of six payment instruments, including coins, banknotes, debit cards, credit cards, mobile payments, and on-line banking, we identify 16 payment characteristics. The characteristics aggregate seventy-six unique...

  12. Specification for Instrumentation

    DEFF Research Database (Denmark)

    Margheritini, Lucia; Kofoed, Jens Peter

    This paper is intended to give an overview on instrumentation for monitoring the efficiency of the Converter and the performance of the device. Real-time control of plant and data monitoring and storage are the main objectives of the control system....

  13. Robotic and Survey Telescopes

    Science.gov (United States)

    Woźniak, Przemysław

    Robotic telescopes are revolutionizing the way astronomers collect their dataand conduct sky surveys. This chapter begins with a discussion of principles thatguide the process of designing, constructing, and operating telescopes andobservatories that offer a varying degree of automation, from instruments remotelycontrolled by observers to fully autonomous systems requiring no humansupervision during their normal operations. Emphasis is placed on designtrade-offs involved in building end-to-end systems intended for a wide range ofscience applications. The second part of the chapter contains descriptions ofseveral projects and instruments, both existing and currently under development.It is an attempt to provide a representative selection of actual systems thatillustrates state of the art in technology, as well as important ideas and milestonesin the development of the field. The list of presented instruments spans the fullrange in size starting from small all-sky monitors, through midrange robotic andsurvey telescopes, and finishing with large robotic instruments and surveys.Explosive growth of telescope networking is enabling entirely new modesof interaction between the survey and follow-up observing. Increasingimportance of standardized communication protocols and software is stressed.These developments are driven by the fusion of robotic telescope hardware,massive storage and databases, real-time knowledge extraction, and datacross-correlation on a global scale. The chapter concludes with examplesof major science results enabled by these new technologies and futureprospects.

  14. The Science of String Instruments

    CERN Document Server

    Rossing, Thomas D

    2010-01-01

    Many performing musicians, as well as instrument builders, are coming to realize the importance of understanding the science of musical instruments. This book explains how string instruments produce sound. It presents basic ideas in simple language, and it also translates some more sophisticated ideas in non-technical language. It should be of interest to performers, researchers, and instrument makers alike.

  15. Methods for estimating properties of hydrocarbons comprising asphaltenes based on their solubility

    Energy Technology Data Exchange (ETDEWEB)

    Schabron, John F.; Rovani, Jr., Joseph F.

    2016-10-04

    Disclosed herein is a method of estimating a property of a hydrocarbon comprising the steps of: preparing a liquid sample of a hydrocarbon, the hydrocarbon having asphaltene fractions therein; precipitating at least some of the asphaltenes of a hydrocarbon from the liquid sample with one or more precipitants in a chromatographic column; dissolving at least two of the different asphaltene fractions from the precipitated asphaltenes during a successive dissolution protocol; eluting the at least two different dissolved asphaltene fractions from the chromatographic column; monitoring the amount of the fractions eluted from the chromatographic column; using detected signals to calculate a percentage of a peak area for a first of the asphaltene fractions and a peak area for a second of the asphaltene fractions relative to the total peak areas, to determine a parameter that relates to the property of the hydrocarbon; and estimating the property of the hydrocarbon.

  16. Nanoscale Cross-Point Resistive Switching Memory Comprising p-Type SnO Bilayers

    KAUST Repository

    Hota, Mrinal Kanti

    2015-02-23

    Reproducible low-voltage bipolar resistive switching is reported in bilayer structures of p-type SnO films. Specifically, a bilayer homojunction comprising SnOx (oxygen-rich) and SnOy (oxygen-deficient) in nanoscale cross-point (300 × 300 nm2) architecture with self-compliance effect is demonstrated. By using two layers of SnO film, a good memory performance is obtained as compared to the individual oxide films. The memory devices show resistance ratio of 103 between the high resistance and low resistance states, and this difference can be maintained for up to 180 cycles. The devices also show good retention characteristics, where no significant degradation is observed for more than 103 s. Different charge transport mechanisms are found in both resistance states, depending on the applied voltage range and its polarity. The resistive switching is shown to originate from the oxygen ion migration and subsequent formation/rupture of conducting filaments.

  17. MOLECULAR FIELD THEORY FOR NEMATIC LIQUID CRYSTAL POLYMER COMPRISING FLEXIBLE SPACER

    Institute of Scientific and Technical Information of China (English)

    WANG Xiaogong; LIU Deshan; ZHOU Qixiang

    1993-01-01

    Based on the new model and concept of intramolecular orientational order parameter, a molecular field theory was built up for main chain liquid crystalline polymer (MC-LCPs) with flexible spacers. The theory takes account of orientational correlation among all mesogens in a polymer chain and the relationship between the intramolecular orientation and spatial orientation of the mesogens. The free energy, temperature and entropy of the nematic-isotropic transition were determined with the theory and compared with experiments in current work. It was found that many unique transition properties of the MC-LCPs comprising flexible spacer are correctly predicted by the theory and the agreement of the theory with the experiments is impressive.

  18. PREPARATION AND CHARACTERIZATION OF COMPOSITES COMPRISING MODIFIED HARDWOOD AND WOOD POLYMERS/POLY(VINYL CHLORIDE

    Directory of Open Access Journals (Sweden)

    Ruxanda Bodîrlău

    Full Text Available Chemical modification of hardwood sawdust from ash-tree species was carried out with a solution of maleic anhydride in acetone. Wood polymers, lignin, and cellulose were isolated from the wood sawdust and modified by the same method. Samples were characterized by Fourier transform infrared spectroscopy (FTIR, providing evidence that maleic anhydride esterifies the free hydroxyl groups of the wood polymer components. Composites comprising chemically modified wood sawdust and wood polymers (cellulose, lignin-as variable weight percentages-, and poly (vinyl chloride were obtained and further characterized by using FTIR spectroscopy and scanning electron microscopy (SEM. The thermal behavior of composites was investigated by using the thermogravimetric analysis (TGA. In all cases, thermal properties were affected by fillers addition.

  19. Formation Mechanistism Study of TiO2 Film Comprising Nanotubes and Nanoparticles

    Institute of Scientific and Technical Information of China (English)

    Di Yang; Yi-quan Wang; Guo-bin Ren; Shuai Feng; Yuan-yuan Chen; Wen-zhong Wang

    2012-01-01

    A novel titanium dioxide (TiO2) film comprising both nanotubes and nanopaticles was fabricated by an anodization process of the modified titanium.The local electric field at the anodized surface was simulated and its influence on the morphology of the TiO2 film was discussed.The results show that the electric field strength is enhanced by the covering.The growth rate of TiO2 increases with the assist of the local electric field.However,TiO2 dissolution is hindered since the local electric field prevents [TiF6]6- from diffusing.It means that the balance condition for the formation of nanotubes is broken,and TiO2 nanoparticles are formed.Moreover,the crystal structure of the TiO2 film was confirmed using X-ray diffraction and Raman analysis.The anatase is a main phase for the proposed film.

  20. Formation Mechanistism Study of TiO2 Film Comprising Nanotubes and Nanoparticles

    Science.gov (United States)

    Yang, Di; Wang, Yi-quan; Ren, Guo-bin; Feng, Shuai; Chen, Yuan-yuan; Wang, Wen-zhong

    2012-02-01

    A novel titanium dioxide (TiO2) film comprising both nanotubes and nanopaticles was fabricated by an anodization process of the modified titanium. The local electric field at the anodized surface was simulated and its influence on the morphology of the TiO2 film was discussed. The results show that the electric field strength is enhanced by the covering. The growth rate of TiO2 increases with the assist of the local electric field. However, TiO2 dissolution is hindered since the local electric field prevents [TiF6]6- from diffusing. It means that the balance condition for the formation of nanotubes is broken, and TiO2 nanoparticles are formed. Moreover, the crystal structure of the TiO2 film was confirmed using X-ray diffraction and Raman analysis. The anatase is a main phase for the proposed film.

  1. Fabrication and Characterization of Cylindrical Light Diffusers Comprised of Shape Memory Polymer

    Energy Technology Data Exchange (ETDEWEB)

    Small IV, W; Buckley, P R; Wilson, T S; Loge, J M; Maitland, K D; Maitland, D J

    2007-01-29

    We have developed a technique for constructing light diffusing devices comprised of a flexible shape memory polymer (SMP) cylindrical diffuser attached to the tip of an optical fiber. Devices were fabricated by casting an SMP rod over the cleaved tip of an optical fiber and media blasting the SMP rod to create a light diffusing surface. The axial and polar emission profiles and circumferential (azimuthal) uniformity were characterized for various blasting pressures, nozzle-to-sample distances, and nozzle translation speeds. The diffusers were generally strongly forward-directed and consistently withstood over 8 W of incident infrared laser light without suffering damage when immersed in water. These devices are suitable for various endoluminal and interstitial biomedical applications.

  2. Physicochemical and Rheological Properties of Optimised Cocoyam-Based Composite Flour Comprising Cassava Starch

    Directory of Open Access Journals (Sweden)

    Awolu Olugbenga Olufemi

    2016-12-01

    Full Text Available Composite flour comprising cocoyam (Colocassia esculenta, bambara groundnut and cassava starch was produced. The proximate and minerals compositions and functional properties were optimized using optimal mixture design of response surface methodology. The antinutritional, pasting and farinograph analyses of the optimum blends were evaluated. Bambara groundnut improved protein, fibre, ash and minerals contents; cassava starch improved swelling capacity, least gelation and pasting characteristics. The optimum blends CBC1 (70% cocoyam flour, 18.33% bambara groundnut flour, 11.67% cassava starch and CBC2 (69.17% cocoyam flour, 16.67% bambara groundnut flour, 14.17% cassava starch. were comparable to wheat–based flour samples (60% wheat, 30% cocoyam, 10% bambara groundnut flours and (72% wheat, 19% cocoyam, 9% bambara groundnut flours in terms of pasting and farinograph analyses.

  3. Optical modulation of nano-gap tunnelling junctions comprising self-assembled monolayers of hemicyanine dyes

    Science.gov (United States)

    Pourhossein, Parisa; Vijayaraghavan, Ratheesh K.; Meskers, Stefan C. J.; Chiechi, Ryan C.

    2016-06-01

    Light-driven conductance switching in molecular tunnelling junctions that relies on photoisomerization is constrained by the limitations of kinetic traps and either by the sterics of rearranging atoms in a densely packed monolayer or the small absorbance of individual molecules. Here we demonstrate light-driven conductance gating; devices comprising monolayers of hemicyanine dyes trapped between two metallic nanowires exhibit higher conductance under irradiation than in the dark. The modulation of the tunnelling current occurs faster than the timescale of the measurement (~1 min). We propose a mechanism in which a fraction of molecules enters an excited state that brings the conjugated portion of the monolayer into resonance with the electrodes. This mechanism is supported by calculations showing the delocalization of molecular orbitals near the Fermi energy in the excited and cationic states, but not the ground state and a reasonable change in conductance with respect to the effective barrier width.

  4. Nucleic acids encoding phloem small RNA-binding proteins and transgenic plants comprising them

    Science.gov (United States)

    Lucas, William J.; Yoo, Byung-Chun; Lough, Tony J.; Varkonyi-Gasic, Erika

    2007-03-13

    The present invention provides a polynucleotide sequence encoding a component of the protein machinery involved in small RNA trafficking, Cucurbita maxima phloem small RNA-binding protein (CmPSRB 1), and the corresponding polypeptide sequence. The invention also provides genetic constructs and transgenic plants comprising the polynucleotide sequence encoding a phloem small RNA-binding protein to alter (e.g., prevent, reduce or elevate) non-cell autonomous signaling events in the plants involving small RNA metabolism. These signaling events are involved in a broad spectrum of plant physiological and biochemical processes, including, for example, systemic resistance to pathogens, responses to environmental stresses, e.g., heat, drought, salinity, and systemic gene silencing (e.g., viral infections).

  5. Transgenic carrot expressing fusion protein comprising M. tuberculosis antigens induces immune response in mice.

    Science.gov (United States)

    Permyakova, Natalia V; Zagorskaya, Alla A; Belavin, Pavel A; Uvarova, Elena A; Nosareva, Olesya V; Nesterov, Andrey E; Novikovskaya, Anna A; Zav'yalov, Evgeniy L; Moshkin, Mikhail P; Deineko, Elena V

    2015-01-01

    Tuberculosis remains one of the major infectious diseases, which continues to pose a major global health problem. Transgenic plants may serve as bioreactors to produce heterologous proteins including antibodies, antigens, and hormones. In the present study, a genetic construct has been designed that comprises the Mycobacterium tuberculosis genes cfp10, esat6 and dIFN gene, which encode deltaferon, a recombinant analog of the human γ-interferon designed for expression in plant tissues. This construct was transferred to the carrot (Daucus carota L.) genome by Agrobacterium-mediated transformation. This study demonstrates that the fusion protein CFP10-ESAT6-dIFN is synthesized in the transgenic carrot storage roots. The protein is able to induce both humoral and cell-mediated immune responses in laboratory animals (mice) when administered either orally or by injection. It should be emphasized that M. tuberculosis antigens contained in the fusion protein have no cytotoxic effect on peripheral blood mononuclear cells.

  6. Infrared absorption on a complex comprising three equivalent hydrogen atoms in ZnO

    Science.gov (United States)

    Herklotz, F.; Hupfer, A.; Johansen, K. M.; Svensson, B. G.; Koch, S. G.; Lavrov, E. V.

    2015-10-01

    A hydrogen-related defect in ZnO which causes two broad IR absorption bands at 3303 and 3321 cm-1 is studied by means of infrared absorption spectroscopy and first-principles theory. In deuterated samples, the defect reveals two sharp absorption lines at 2466 and 2488 cm-1 accompanied by weaker sidebands at 2462 and 2480 cm-1. Isotope substitution experiments with varying concentrations of H and D together with polarization-sensitive measurements strongly suggest that these IR absorption lines are due to stretch local vibrational modes of a defect comprising three equivalent hydrogen atoms. The zinc vacancy decorated by three hydrogen atoms, VZnH3 , and ammonia trapped at the zinc vacancy, (NH3)Zn, are discussed as a possible origin for the complex.

  7. Superhydrophobic, diatomaceous earth comprising bandages and method of making the same

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, John T.; D' Urso, Brian R.

    2017-01-10

    A bandage comprising a substrate having a first surface with a plurality of superhydrophobic particles attached to the first surface. The plurality of superhydrophobic particles can be porous diatomaceous earth particles having a hydrophobic layer conforming to the surfaces of the DE particles, where the hydrophobic layer is bound to the DE particles. The plurality of attached superhydrophobic particles can render the first surface superhydrophobic, while a second surface opposite the first surface can be hydrophilic or hydrophobic. The substrate can be breathable in order to maintain skin health for the tissue underlying the bandage. The substrate can be selected from porous films, apertured films, textiles, nonwoven materials, impregnated composites thereof, and combinations thereof.

  8. A construction and a tension element comprising a cable and a plurality of strakes

    DEFF Research Database (Denmark)

    2014-01-01

    The invention provides a construction comprising a structural element and at least one cable (100) arranged in tension to carry at least a part of the weight of the structural element. The cable defines an outer surface (102) onto which a plurality of strakes (104) form protrusions for reducing...... rain and wind induced vibrations. Each strake has a height being a distance from a strake root part connected to the outer surface of the cable and a strake end part terminating the strake outwards form the cable, a width being transverse to the height, and a length transverse to the height and width...... and along which length the strake is connected to the cable. The length of each strake is shorter than the circumference of the outer surface, and the height is less than 5 percent of the diameter of the cable....

  9. Analysis and Design of Ultra Thin Electromagnetic Absorbers Comprising Resistively Loaded High Impedance Surfaces

    CERN Document Server

    Costa, Filippo; Manara, Giuliano; 10.1109/TAP.2010.2044329

    2010-01-01

    High-Impedance Surfaces (HIS) comprising lossy Frequency Selective Surfaces (FSS) are employed to design thin electromagnetic absorbers. The structure, despite its typical resonant behavior, is able to perform a very wideband absorption in a reduced thickness. Losses in the frequency selective surface are introduced by printing the periodic pattern through resistive inks and hence avoiding the typical soldering of a large number of lumped resistors. The effect of the surface resistance of the FSS and dielectric substrate characteristics on the input impedance of the absorber is discussed by means of a circuital model. It is shown that the optimum value of surface resistance is affected both by substrate parameters (thickness and permittivity) and by FSS element shape. The equivalent circuit model is then used to introduce the working principles of the narrowband and the wideband absorbing structure and to derive the best-suited element for wideband absorption. Finally, the experimental validation of the prese...

  10. Cobalamin status during normal pregnancy and postpartum: a longitudinal study comprising 406 danish women

    DEFF Research Database (Denmark)

    Milman, N; Byg, KE; Bergholt, T;

    2006-01-01

    OBJECTIVES: To assess cobalamin (vitamin B(12)) status during normal pregnancy and postpartum in a longitudinal setting. METHODS: This study was performed in 1995-1996. It comprised 406 healthy, pregnant Danish Caucasian women, living in Copenhagen County. Cobalamin status, i.e. plasma (P......-) cobalamin, P-methylmalonic acid and P-homocysteine was measured at 18, 32 and 39 wk gestation and 8 wk postpartum during lactation. RESULTS: P-cobalamin showed a gradual, significant decline during pregnancy (P ... and 8 wk postpartum median values were 225, 172, 161 and 319 pmol/L, respectively. P-methylmalonic displayed a gradual, significant increase during pregnancy as well as postpartum (P homocysteine demonstrated...

  11. Crystal structures of two ytterbium(III complexes comprising alkynylamidinate ligands

    Directory of Open Access Journals (Sweden)

    Sida Wang

    2016-09-01

    Full Text Available Two ytterbium(III complexes comprising alkynylamidinate ligands, namely bis(η5-cyclopentadienyl(3-cyclopropyl-N,N′-diisopropylpropynamidinato-κ2N,N′ytterbium(III, [Yb(C5H52(C12H19N2] or Cp2Yb[(iPr2N2C—C[triple-bond]C—c-C3H5] (1 and tris(3-phenyl-N,N′-dicyclohexylpropynamidinato-κ2N,N′ytterbium(III, [Yb(C21H27N23] or Yb[(CyN2C—C[triple-bond]C—Ph]3 (Cy = cyclohexyl (2 have been synthesized and structurally characterized. Both complexes are monomers; for complex 2, the contribution to the scattering from highly disordered toluene solvent molecules in these voids was removed with the SQUEEZE routine [Spek (2015. Acta Cryst. C71, 9–18] in PLATON. The stated crystal data for Mr, μ etc. do not take these into account.

  12. Transgenic Carrot Expressing Fusion Protein Comprising M. tuberculosis Antigens Induces Immune Response in Mice

    Directory of Open Access Journals (Sweden)

    Natalia V. Permyakova

    2015-01-01

    Full Text Available Tuberculosis remains one of the major infectious diseases, which continues to pose a major global health problem. Transgenic plants may serve as bioreactors to produce heterologous proteins including antibodies, antigens, and hormones. In the present study, a genetic construct has been designed that comprises the Mycobacterium tuberculosis genes cfp10, esat6 and dIFN gene, which encode deltaferon, a recombinant analog of the human γ-interferon designed for expression in plant tissues. This construct was transferred to the carrot (Daucus carota L. genome by Agrobacterium-mediated transformation. This study demonstrates that the fusion protein CFP10-ESAT6-dIFN is synthesized in the transgenic carrot storage roots. The protein is able to induce both humoral and cell-mediated immune responses in laboratory animals (mice when administered either orally or by injection. It should be emphasized that M. tuberculosis antigens contained in the fusion protein have no cytotoxic effect on peripheral blood mononuclear cells.

  13. Health Outcomes Survey - Limited Data Set

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Medicare Health Outcomes Survey (HOS) limited data sets (LDS) are comprised of the entire national sample for a given 2-year cohort (including both respondents...

  14. Identifiable Data Files - Health Outcomes Survey (HOS)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Medicare Health Outcomes Survey (HOS) identifiable data files are comprised of the entire national sample for a given 2-year cohort (including both respondents...

  15. Kinetic analysis of overlapping multistep thermal decomposition comprising exothermic and endothermic processes: thermolysis of ammonium dinitramide.

    Science.gov (United States)

    Muravyev, Nikita V; Koga, Nobuyoshi; Meerov, Dmitry B; Pivkina, Alla N

    2017-01-25

    This study focused on kinetic modeling of a specific type of multistep heterogeneous reaction comprising exothermic and endothermic reaction steps, as exemplified by the practical kinetic analysis of the experimental kinetic curves for the thermal decomposition of molten ammonium dinitramide (ADN). It is known that the thermal decomposition of ADN occurs as a consecutive two step mass-loss process comprising the decomposition of ADN and subsequent evaporation/decomposition of in situ generated ammonium nitrate. These reaction steps provide exothermic and endothermic contributions, respectively, to the overall thermal effect. The overall reaction process was deconvoluted into two reaction steps using simultaneously recorded thermogravimetry and differential scanning calorimetry (TG-DSC) curves by considering the different physical meanings of the kinetic data derived from TG and DSC by P value analysis. The kinetic data thus separated into exothermic and endothermic reaction steps were kinetically characterized using kinetic computation methods including isoconversional method, combined kinetic analysis, and master plot method. The overall kinetic behavior was reproduced as the sum of the kinetic equations for each reaction step considering the contributions to the rate data derived from TG and DSC. During reproduction of the kinetic behavior, the kinetic parameters and contributions of each reaction step were optimized using kinetic deconvolution analysis. As a result, the thermal decomposition of ADN was successfully modeled as partially overlapping exothermic and endothermic reaction steps. The logic of the kinetic modeling was critically examined, and the practical usefulness of phenomenological modeling for the thermal decomposition of ADN was illustrated to demonstrate the validity of the methodology and its applicability to similar complex reaction processes.

  16. Highly diverse nirK genes comprise two major clades that harbour ammonium-producing denitrifiers

    OpenAIRE

    2016-01-01

    Background Copper dependent nitrite reductase, NirK, catalyses the key step in denitrification, i.e. nitrite reduction to nitric oxide. Distinct structural NirK classes and phylogenetic clades of NirK-type denitrifiers have previously been observed based on a limited set of NirK sequences, however, their environmental distribution or ecological strategies are currently unknown. In addition, environmental nirK-type denitrifiers are currently underestimated in PCR-dependent surveys due to prime...

  17. UC Merced NMR Instrumentation Acquisition

    Science.gov (United States)

    2015-06-18

    UC Merced NMR Instrumentation Acquisition For the UC Merced NMR Instrumentation Acquisition proposal, a new 400 MHz and an upgraded 500 MHz NMR ...UC Merced NMR Instrumentation Acquisition Report Title For the UC Merced NMR Instrumentation Acquisition proposal, a new 400 MHz and an upgraded 500...MHz NMR have been delivered, installed, and incorporated into research and two lab courses. While no results from these instruments have been

  18. netherland hydrological modeling instrument

    Science.gov (United States)

    Hoogewoud, J. C.; de Lange, W. J.; Veldhuizen, A.; Prinsen, G.

    2012-04-01

    Netherlands Hydrological Modeling Instrument A decision support system for water basin management. J.C. Hoogewoud , W.J. de Lange ,A. Veldhuizen , G. Prinsen , The Netherlands Hydrological modeling Instrument (NHI) is the center point of a framework of models, to coherently model the hydrological system and the multitude of functions it supports. Dutch hydrological institutes Deltares, Alterra, Netherlands Environmental Assessment Agency, RWS Waterdienst, STOWA and Vewin are cooperating in enhancing the NHI for adequate decision support. The instrument is used by three different ministries involved in national water policy matters, for instance the WFD, drought management, manure policy and climate change issues. The basis of the modeling instrument is a state-of-the-art on-line coupling of the groundwater system (MODFLOW), the unsaturated zone (metaSWAP) and the surface water system (MOZART-DM). It brings together hydro(geo)logical processes from the column to the basin scale, ranging from 250x250m plots to the river Rhine and includes salt water flow. The NHI is validated with an eight year run (1998-2006) with dry and wet periods. For this run different parts of the hydrology have been compared with measurements. For instance, water demands in dry periods (e.g. for irrigation), discharges at outlets, groundwater levels and evaporation. A validation alone is not enough to get support from stakeholders. Involvement from stakeholders in the modeling process is needed. There fore to gain sufficient support and trust in the instrument on different (policy) levels a couple of actions have been taken: 1. a transparent evaluation of modeling-results has been set up 2. an extensive program is running to cooperate with regional waterboards and suppliers of drinking water in improving the NHI 3. sharing (hydrological) data via newly setup Modeling Database for local and national models 4. Enhancing the NHI with "local" information. The NHI is and has been used for many

  19. Developments in analytical instrumentation

    Science.gov (United States)

    Petrie, G.

    The situation regarding photogrammetric instrumentation has changed quite dramatically over the last 2 or 3 years with the withdrawal of most analogue stereo-plotting machines from the market place and their replacement by analytically based instrumentation. While there have been few new developments in the field of comparators, there has been an explosive development in the area of small, relatively inexpensive analytical stereo-plotters based on the use of microcomputers. In particular, a number of new instruments have been introduced by manufacturers who mostly have not been associated previously with photogrammetry. Several innovative concepts have been introduced in these small but capable instruments, many of which are aimed at specialised applications, e.g. in close-range photogrammetry (using small-format cameras); for thematic mapping (by organisations engaged in environmental monitoring or resources exploitation); for map revision, etc. Another innovative and possibly significant development has been the production of conversion kits to convert suitable analogue stereo-plotting machines such as the Topocart, PG-2 and B-8 into fully fledged analytical plotters. The larger and more sophisticated analytical stereo-plotters are mostly being produced by the traditional mainstream photogrammetric systems suppliers with several new instruments and developments being introduced at the top end of the market. These include the use of enlarged photo stages to handle images up to 25 × 50 cm format; the complete integration of graphics workstations into the analytical plotter design; the introduction of graphics superimposition and stereo-superimposition; the addition of correlators for the automatic measurement of height, etc. The software associated with this new analytical instrumentation is now undergoing extensive re-development with the need to supply photogrammetric data as input to the more sophisticated G.I.S. systems now being installed by clients, instead

  20. "The Burden of Pregnancy"; heavier for the heaviest? The changes in Health Related Quality of Life (HRQoL) assessed by the 15D instrument during pregnancy and postpartum in different body mass index groups: a longitudinal survey.

    Science.gov (United States)

    Sahrakorpi, Niina; Koivusalo, Saila B; Stach-Lempinen, Beata; Eriksson, Johan G; Kautiainen, Hannu; Roine, Risto P

    2017-03-01

    Only little information is available on health-related quality of life (HRQoL) and its changes during the course of a normal pregnancy. We studied changes in HRQoL in a pregnant population during pregnancy and until 1 year postpartum in different body mass index (BMI) groups. Seven hundred and fifty pregnant women attending the first ultrasound examination before gestational week 14 were invited to participate in a longitudinal, communal-based survey. The participants were divided into three groups according to their BMI; <25, 25-29.9, and ≥30 kg/m(2) . The women were asked to fill in questionnaires assessing HRQoL (15D), depressive symptoms (Edinburgh Depression Scale, EPDS), medical, obstetric and socioeconomic status at baseline. HRQoL and EPDS were re-assessed at 30 weeks of gestation, and 6 weeks, 3 and 12 months postpartum. Of the invited 750 mothers, 325 (43%) returned the questionnaires and at least one follow-up questionnaire. At baseline, mean 15D scores decreased with increasing BMI but the difference was not statistically significant when adjusted for age, educational attainment, parity or EPDS-scores (0.929, 0.921 and 0.916, p = 0.16). During the course of pregnancy, the HRQoL of all women decreased but this decrease was significantly greater in the obese group (-0.088; 95% CI -0.110 to -0.065) than in the other groups [-0.054 (95% CI -0.062 to -0.045) and -0.051 (95% CI -0.068 to -0.033), p = 0.019]. Within 3 months postpartum the mean HRQoL recovered in all BMI groups to baseline levels, irrespective of the mode of delivery or pregnancy-related complications. The burden of pregnancy is heavier for the heaviest. © 2016 Nordic Federation of Societies of Obstetrics and Gynecology.

  1. A Life in the Universe Survey

    Science.gov (United States)

    LoPresto, Michael C.; Hubble-Zdanowski, Jennifer

    2012-01-01

    The "Life in the Universe Survey" is a twelve-question assessment instrument. Largely based on the factors of the Drake equation, it is designed to survey students' initial estimates of its factors and to gauge how estimates change with instruction. The survey was used in sections of a seminar course focusing specifically on life in the universe…

  2. A Life in the Universe Survey

    Science.gov (United States)

    LoPresto, Michael C.; Hubble-Zdanowski, Jennifer

    2012-01-01

    The "Life in the Universe Survey" is a twelve-question assessment instrument. Largely based on the factors of the Drake equation, it is designed to survey students' initial estimates of its factors and to gauge how estimates change with instruction. The survey was used in sections of a seminar course focusing specifically on life in the universe…

  3. Instrumentation problems for physicians.

    Science.gov (United States)

    Turner, G O

    1980-01-01

    The physician has, for whatever reasons, diminished his or her level of involvement on the team dedicated to developing, refining, and evaluating medical technology. As a result, the challenge confronting the physician and the technology development team today is to orchestrate a team structure that will ensure the greatest input and commitment from physicians and other professionals during current and future technology development. The charges of cost escalation and dehumanization in our system of health care delivery will also be discussed, as will the lack of, or confusion about, access to data concerning cost of a given instrument, and fuzzy semantics and perspectives on technology and instrumentation. The author suggests answers to, or means to ameliorate, the problems.

  4. KEKB beam instrumentation systems

    Science.gov (United States)

    Arinaga, M.; Flanagan, J.; Hiramatsu, S.; Ieiri, T.; Ikeda, H.; Ishii, H.; Kikutani, E.; Mimashi, T.; Mitsuhashi, T.; Mizuno, H.; Mori, K.; Tejima, M.; Tobiyama, M.

    2003-02-01

    For the stable high-luminosity operation and luminosity increase, the electron and positron storage rings of the KEK B-Factory (KEKB) is equipped with various beam instrumentations, which have been working well since the start of the commissioning in December, 1998. Details and performance of the beam-position monitor system based on the spectrum analysis using DSPs, the turn-by-turn BPM with four-dimensional function available for measurements of the individual bunch position, phase and intensity, the parametric beam-DCCTs designed so as to avoid the magnetic-core-selection problems for the parametric flux modulation, the bunch-by-bunch feedback system indispensable to suppress the strong multibunch instabilities in KEKB, the various optical beam diagnostic systems, such as synchrotron radiation interferometers for precise beam-size measurement, the tune meters, the bunch length monitors and the beam-loss monitors are described. Delicate machine tuning of KEKB is strongly supported by these instrumentations.

  5. Data acquisition instruments: Psychopharmacology

    Energy Technology Data Exchange (ETDEWEB)

    Hartley, D.S. III

    1998-01-01

    This report contains the results of a Direct Assistance Project performed by Lockheed Martin Energy Systems, Inc., for Dr. K. O. Jobson. The purpose of the project was to perform preliminary analysis of the data acquisition instruments used in the field of psychiatry, with the goal of identifying commonalities of data and strategies for handling and using the data in the most advantageous fashion. Data acquisition instruments from 12 sources were provided by Dr. Jobson. Several commonalities were identified and a potentially useful data strategy is reported here. Analysis of the information collected for utility in performing diagnoses is recommended. In addition, further work is recommended to refine the commonalities into a directly useful computer systems structure.

  6. An ice lithography instrument

    Science.gov (United States)

    Han, Anpan; Chervinsky, John; Branton, Daniel; Golovchenko, J. A.

    2011-06-01

    We describe the design of an instrument that can fully implement a new nanopatterning method called ice lithography, where ice is used as the resist. Water vapor is introduced into a scanning electron microscope (SEM) vacuum chamber above a sample cooled down to 110 K. The vapor condenses, covering the sample with an amorphous layer of ice. To form a lift-off mask, ice is removed by the SEM electron beam (e-beam) guided by an e-beam lithography system. Without breaking vacuum, the sample with the ice mask is then transferred into a metal deposition chamber where metals are deposited by sputtering. The cold sample is then unloaded from the vacuum system and immersed in isopropanol at room temperature. As the ice melts, metal deposited on the ice disperses while the metals deposited on the sample where the ice had been removed by the e-beam remains. The instrument combines a high beam-current thermal field emission SEM fitted with an e-beam lithography system, cryogenic systems, and a high vacuum metal deposition system in a design that optimizes ice lithography for high throughput nanodevice fabrication. The nanoscale capability of the instrument is demonstrated with the fabrication of nanoscale metal lines.

  7. Impact dynamics instrumentation

    Science.gov (United States)

    Mccormck, R. F.

    1986-01-01

    One of the tasks specified in the NASA Langley controlled impact demonstration (CID) work package was to furnish dynamic instrumentation sensors. The types of instrumentation sensors required were accelerometers for aircraft structural loads measurements, seat belt load cells to measure anthropomorphic dummy responses to the aircraft impact, and strain gage bending bridges to measure the aircraft fuselage and wing bending during impact. The objective in the selection of dynamic instrumentation for the CID was to provide 352 of the highest quality transducers and remain within budget allocation. The transducers that were selected for the CID evaluation process were each subjected to rigorous laboratory acceptance tests and to aircraft fuselage section drop tests at the LaRC Impact Dynamics Research Facility. Data compiled from this series of tests showed the selected transducers to be best suited for the CID mission requirement. The transducers installation technique on the airframe proved successful. The transducer quality assurance was guaranteed through rigorous acceptance testing. Data acquired was 97.0%.

  8. Survey of the Frequency Dependent Latitudinal Distribution of the Fast Magnetosonic Wave Mode from Van Allen Probes Electric and Magnetic Field Instrument and Integrated Science Waveform Receiver Plasma Wave Analysis

    Science.gov (United States)

    Boardsen, Scott A.; Hospodarsky, George B.; Kletzing, Craig A.; Engebretson, Mark J.; Pfaff, Robert F.; Wygant, John R.; Kurth, William S.; Averkamp, Terrance F.; Bounds, Scott R.; Green, Jim L.; hide

    2016-01-01

    We present a statistical survey of the latitudinal structure of the fast magnetosonic wave mode detected by the Van Allen Probes spanning the time interval of 21 September 2012 to 1 August 2014. We show that statistically, the latitudinal occurrence of the wave frequency (f) normalized by the local proton cyclotron frequency (f(sub cP)) has a distinct funnel-shaped appearance in latitude about the magnetic equator similar to that found in case studies. By comparing the observed E/B ratios with the model E/B ratio, using the observed plasma density and background magnetic field magnitude as input to the model E/B ratio, we show that this mode is consistent with the extra-ordinary (whistler) mode at wave normal angles (theta(sub k)) near 90 deg. Performing polarization analysis on synthetic waveforms composed from a superposition of extra-ordinary mode plane waves with theta(sub k) randomly chosen between 87 and 90 deg, we show that the uncertainty in the derived wave normal is substantially broadened, with a tail extending down to theta(sub k) of 60 deg, suggesting that another approach is necessary to estimate the true distribution of theta(sub k). We find that the histograms of the synthetically derived ellipticities and theta(sub k) are consistent with the observations of ellipticities and theta(sub k) derived using polarization analysis.We make estimates of the median equatorial theta(sub k) by comparing observed and model ray tracing frequency-dependent probability occurrence with latitude and give preliminary frequency dependent estimates of the equatorial theta(sub k) distribution around noon and 4 R(sub E), with the median of approximately 4 to 7 deg from 90 deg at f/f(sub cP) = 2 and dropping to approximately 0.5 deg from 90 deg at f/f(sub cP) = 30. The occurrence of waves in this mode peaks around noon near the equator at all radial distances, and we find that the overall intensity of these waves increases with AE*, similar to findings of other studies.

  9. Advancements in Actuated Musical Instruments

    DEFF Research Database (Denmark)

    Overholt, Daniel; Berdahl, Edgar; Hamilton, Robert

    2011-01-01

    This article presents recent developments in actuated musical instruments created by the authors, who also describe an ecosystemic model of actuated performance activities that blur traditional boundaries between the physical and virtual elements of musical interfaces. Actuated musical instrument...... that these instruments enable. We look at some of the conceptual and perceptual issues introduced by actuated musical instruments, and finally we propose some directions in which such research may be headed in the future.......This article presents recent developments in actuated musical instruments created by the authors, who also describe an ecosystemic model of actuated performance activities that blur traditional boundaries between the physical and virtual elements of musical interfaces. Actuated musical instruments...... are physical instruments that have been endowed with virtual qualities controlled by a computer in real-time but which are nevertheless tangible. These instruments provide intuitive and engaging new forms of interaction. They are different from traditional (acoustic) and fully automated (robotic) instruments...

  10. FHR Process Instruments

    Energy Technology Data Exchange (ETDEWEB)

    Holcomb, David Eugene [ORNL

    2015-01-01

    Fluoride salt-cooled High temperature Reactors (FHRs) are entering into early phase engineering development. Initial candidate technologies have been identified to measure all of the required process variables. The purpose of this paper is to describe the proposed measurement techniques in sufficient detail to enable assessment of the proposed instrumentation suite and to support development of the component technologies. This paper builds upon the instrumentation chapter of the recently published FHR technology development roadmap. Locating instruments outside of the intense core radiation and high-temperature fluoride salt environment significantly decreases their environmental tolerance requirements. Under operating conditions, FHR primary coolant salt is a transparent, low-vapor-pressure liquid. Consequently, FHRs can employ standoff optical measurements from above the salt pool to assess in-vessel conditions. For example, the core outlet temperature can be measured by observing the fuel s blackbody emission. Similarly, the intensity of the core s Cerenkov glow indicates the fission power level. Short-lived activation of the primary coolant provides another means for standoff measurements of process variables. The primary coolant flow and neutron flux can be measured using gamma spectroscopy along the primary coolant piping. FHR operation entails a number of process measurements. Reactor thermal power and core reactivity are the most significant variables for process control. Thermal power can be determined by measuring the primary coolant mass flow rate and temperature rise across the core. The leading candidate technologies for primary coolant temperature measurement are Au-Pt thermocouples and Johnson noise thermometry. Clamp-on ultrasonic flow measurement, that includes high-temperature tolerant standoffs, is a potential coolant flow measurement technique. Also, the salt redox condition will be monitored as an indicator of its corrosiveness. Both

  11. The standard instrumentation feedthrough system for the LHC cryomagnets

    CERN Document Server

    Bozzini, Davide

    2002-01-01

    For the LHC, 1232 dipole magnets and about 400 quadrupole magnets operating at 1.9 K are installed in arcs and dispersion suppressors. Each cryo-magnet assembly comprises the main magnet and several small corrector magnets. Each assembly is equipped with voltage taps, quench heaters and cryogenic instrumentation. The number of instrumentation wires serving each magnet assembly and passing from cold to ambient is between 36 and 40. An Instrumentation Feedthrough System (IFS) will electrically and mechanically connect the instrument wires to the outside of the vacuum vessel. The IFS has to satisfy several requirements: simplicity of integration, optimal access during tests and commissioning, voltage withstand and reliability during the lifetime of the machine. The heat load to superfluid helium must be minimized, and the long-term stability of the insulation vacuum should be preserved. The solution foresees an open stainless steel tube housing the wires connected between the magnet and the outside of the vacuum...

  12. Capturing of the internal mechanics of liquid-granular flows comprised of polydisperse spherical particles

    Science.gov (United States)

    Gollin, Devis; Bowman, Elisabeth

    2017-06-01

    This paper presents a series of flume experiments designed to examine the motion and arrest of concentrated granular-fluid flows, with a view to understanding the role of polydispersity in debris flows. A non-intrusive technique is used to investigate the internal behaviour of small scale experimental flows. Three different particle size distributions comprised of polydisperse spherical particles and one with the finer component made of angular particles were analysed. The choice of using spherical shaped particles was made to improve the visualization of the internal mechanics without reducing overmuch the complexity involved in the study of these flows. We examined and compared the internal velocities of the flows and their depositional spreads. While the optical performance of the non-intrusive technique was improved, some of the characteristics commonly seen in these types of granular flows were not observed. Velocity profiles obtained in the body of the flows were similar in shape but with differences in velocity magnitude depending on the amount of fines and the angularity of the particle in one case. Depositional runouts between flows were similar at low inclinations when little internal energy was supplemented to the system or when the viscous effects dominated the mechanics at steeper angles.

  13. Polymeric media comprising polybenzimidazoles N-substituted with organic-inorganic hybrid moiety

    Science.gov (United States)

    Klaehn, John R [Idaho Falls, ID; Peterson, Eric S [Idaho Falls, ID; Wertsching, Alan K [Idaho Falls, ID; Orme, Christopher J [Shelley, ID; Luther, Thomas A [Idaho Falls, ID; Jones, Michael G [Pocatello, ID

    2009-12-15

    A PBI compound includes imidazole nitrogens at least a portion of which are substituted with an organic-inorganic hybrid moiety may be included in a separator medium. At least 85% of the imidazole nitrogens may be substituted. The organic-inorganic hybrid moiety may be an organosilane moiety, for example, (R)Me.sub.2SiCH.sub.2-- where R is selected from among methyl, phenyl, vinyl, and allyl. The separatory medium may exhibit an H.sub.2, Ar, N.sub.2, O.sub.2, CH.sub.3, or CO.sub.2 gas permeability greater than the gas permeability of a comparable separatory medium comprising the PBI compound without substitution. The separatory medium may further include an electronically conductive medium and/or ionically conductive medium. The separatory medium may be used as a membrane (semi-permeable, permeable, and non-permeable), a barrier, an ion exhcange media, a filter, a gas chromatography coating (such as stationary phase coating in affinity chromatography), etc.

  14. Solid dispersion matrix tablet comprising indomethacin-PEG-HPMC fabricated with fusion and mold technique

    Directory of Open Access Journals (Sweden)

    Mesnukul A

    2009-01-01

    Full Text Available The purpose of this study is to fabricate the polyethylene glycol matrix tablet by mold technique. Indomethacin and hydroxypropylmethylcellulose were used as model drug and polymer, respectively, in PEG matrix system. The physical and drug release characteristics of developed matrix tablet were studied. This inert carrier system comprising 7:3 polyethylene glycol 4000: polyethylene glycol 400 could effectively enhance the solubility of indomethacin and an addition of hydroxypropylmethylcellulose could sustain the drug release. Scanning electron microscope photomicrograph indicated the drug diffusion outward through the porous network of this developed matrix tablet into the dissolution fluid. Least square fitting the experimental dissolution data to the mathematical expressions (power law, first-order, Higuchi′s and zero-order indicated the drug release kinetics primarily as Fickian diffusion. Both the enhancement of drug dissolution and the prolongation of the drug release could be achieved for aqueous insoluble drug such as, indomethacin, by using polyethylene glycol-hydroxypropylmethylcellulose matrix system prepared with melting and mold technique.

  15. Control-Oriented Model of a Generating Set Comprising a Diesel Engine and a Synchronous Generator

    Directory of Open Access Journals (Sweden)

    Mutaz Tuffaha

    2015-10-01

    Full Text Available A generating set (Genset comprises a prime mover such as a Diesel Engine, and a synchronous generator. The most important controllers of such systems are the speed governor to regulate the engine or shaft speed and the automatic voltage regulator (AVR to regulate the terminal voltage. The speed governor is a PID controller that uses the difference between the speed and its desired value as a feedback signal to change the fuel mass input by changing the fuel rack position. AVR is also a PID that uses the difference between the terminal voltage of the generator and its desired value, and changes it by manipulating the voltage of the field excitation circuit. Thus, the two controllers act separately. That is to say, if the speed varies from the desired value, the speed governor will react, while the AVR will not react as long as the voltage is stable, and vice versa. In this work, a control-oriented model is suggested for a Genset, and then a controller, that regulates the shaft speed and the terminal voltage, is designed by feedback linearisation. The proposed controller has two inputs: the fuel mass and the field circuit voltage. Simulations show that the proposed controller makes the two inputs act, simultaneously. Thus, any change of the speed e.g., forces the two input controls to react, in contrast to the ordinary PID controllers. Further, we discuss the robustness of the proposed controller to uncertainties and time delay.

  16. Structure formation in adsorbed overlayers comprising functional cross-shaped molecules: A Monte Carlo study

    Science.gov (United States)

    Kasperski, Adam; Nieckarz, Damian; Szabelski, Paweł

    2015-11-01

    Surface confined self-assembly of functional star-shaped organic molecules is a promising method to create nanoporous networks with tailorable structure and functions. In this work we use the Monte Carlo simulation method to demonstrate how the morphology of these supramolecular assemblies can be tuned by manipulating intrinsic parameters of the building blocks and modified by the presence of co-adsorbed metal atoms. To that purpose we study the 2D self-assembly of planar cruciform molecules modeled as collections of interconnected segments, some of which were activated to represent discrete interaction centers. We consider a few exemplary adsorbed systems in which the molecules with different size, aspect ratio and intramolecular distribution of active centers form superstructures stabilized by short-range segment-segment interactions or by metal-segment interactions. These two situations correspond to supramolecular assemblies sustained by, for example, hydrogen bonding and metal-organic ligand coordination, respectively. The simulated results show that proper encoding of intramolecular interactions into the cruciform building bricks allows for directing the self-assembly towards largely diversified structures ranging from nanoclusters to porous grids. The obtained findings can facilitate designing and optimization of molecular networks comprising cross-shaped units including functionalized porphyrins and phthalocyanines and they can be helpful in preliminary selection of these building blocks.

  17. Stability Assessment of a System Comprising a Single Machine and Inverter with Scalable Ratings

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Brian B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Lin, Yashen [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Gevorgian, Vahan [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-28

    From the inception of power systems, synchronous machines have acted as the foundation of large-scale electrical infrastructures and their physical properties have formed the cornerstone of system operations. However, power electronics interfaces are playing a growing role as they are the primary interface for several types of renewable energy sources and storage technologies. As the role of power electronics in systems continues to grow, it is crucial to investigate the properties of bulk power systems in low inertia settings. In this paper, we assess the properties of coupled machine-inverter systems by studying an elementary system comprised of a synchronous generator, three-phase inverter, and a load. Furthermore, the inverter model is formulated such that its power rating can be scaled continuously across power levels while preserving its closed-loop response. Accordingly, the properties of the machine-inverter system can be assessed for varying ratios of machine-to-inverter power ratings and, hence, differing levels of inertia. After linearizing the model and assessing its eigenvalues, we show that system stability is highly dependent on the interaction between the inverter current controller and machine exciter, thus uncovering a key concern with mixed machine-inverter systems and motivating the need for next-generation grid-stabilizing inverter controls.

  18. Polyionic hybrid nano-engineered systems comprising alginate and chitosan for antihypertensive therapeutics.

    Science.gov (United States)

    Niaz, Taskeen; Nasir, Habib; Shabbir, Saima; Rehman, Asma; Imran, Muhammad

    2016-10-01

    Hydrophobic nature of virtually all antihypertensive (AHT) drugs is the major hindrance towards their oral administration. Current study focuses on the development of polyionic hybrid nano drug delivery systems comprising sodium alginate and chitosan, loaded with distinct AHT drugs (captopril, amlodipine and valsartan). Encapsulation efficiency of hybrid NCS increased in the order of amlodipine>valsartan>captopril with average value of 42±0.9%, 91±1.5% and 96±1.9%, respectively. Scanning electron microscopy revealed hybrid NCS with smooth topography and round appearance in case of captopril. FTIR analysis confirmed the cross-linking between amino and carboxylate group of chitosan and alginate to form polyionic structures at nano-scale. Zeta-sizer experiments revealed that particle size distribution had increased from 197±12nm to 341±15nm for void and captopril loaded NCS. However, highly positive zeta potential of +32±1.6mV was not decreased significantly. In vitro sustained release assays reflected excellent retention of AHT drug in hybrid nanoparticles at 4°C and 37°C in physiological buffer, as less than 8% of the total drug was released in first 24h. Thus, carbohydrate-based hybrid NCS offering high loading capacity, stability and sustained release of hydrophobic drugs can be excellent alternative to current AHT therapeutics.

  19. Crystal structures of two ytterbium(III) complexes comprising alkynylamidinate ligands.

    Science.gov (United States)

    Wang, Sida; Sroor, Farid M; Liebing, Phil; Lorenz, Volker; Hilfert, Liane; Edelmann, Frank T

    2016-09-01

    Two ytterbium(III) complexes comprising alkynylamidinate ligands, namely bis-(η(5)-cyclo-penta-dien-yl)(3-cyclo-propyl-N,N'-diiso-propyl-propynamidinato-κ(2)N,N')ytterbium(III), [Yb(C5H5)2(C12H19N2)] or Cp2Yb[( (i) Pr2N)2C-C≡C-c-C3H5] (1) and tris-(3-phenyl-N,N'-di-cyclo-hexyl-propynamidinato-κ(2)N,N')ytterbium(III), [Yb(C21H27N2)3] or Yb[(CyN)2C-C≡C-Ph]3 (Cy = cyclo-hex-yl) (2) have been synthesized and structurally characterized. Both complexes are monomers; for complex 2, the contribution to the scattering from highly disordered toluene solvent molecules in these voids was removed with the SQUEEZE routine [Spek (2015). Acta Cryst. C71, 9-18] in PLATON. The stated crystal data for Mr, μ etc. do not take these into account.

  20. IDIOMS THAT COMPRISE THE PRESENCE OF TURKISH WORDS IN GREEK CYPRIOT LANGUAGE

    Directory of Open Access Journals (Sweden)

    Şevket ÖZNUR

    2010-04-01

    Full Text Available In this communiqué again we preferred to present some examples from the effects of Turkish Cypriot Culture. For a few years, we have concentrated on our culture’s effect on other cultures in Cyprus. Bearing in mind that we have lived together for hundreds of years with other societies, we have seen fit to give examples of the cultural interaction between other cultures and Turkish Cypriot culture. Our communiqué mostly comprises the effects of Turkish Culture. We have found it convenient to present idioms rather than words. As it can be seen from the examples, in every Greek saying there is a Turkish word. For that reason, we have chosen our title as “Turkish Idioms in Greek Cypriot Language”. These idioms which have the clear evidence of the effect of Turkish Culture have been limited with only 71 examples due to shortage of time. We are happy to be able to contribute to our culture. Now with our best regards we would like to start presenting the examples.

  1. Hybrid Layered Crystal Comprising Polyoxometalate and Surfactant Synthesized from Reduced Mo-Blue Species

    Directory of Open Access Journals (Sweden)

    Keisuke Mikurube

    2013-01-01

    Full Text Available A hybrid layered crystal containing polyoxomolybdate was successfully synthesized from reduced Mo-blue species as starting material. The hybrid crystal, [C5H5N(C16H33]2[β-H2Mo8O26]·2C2H5OH (C16py-H2Mo8, was obtained as a single phase by the gradual oxidation of hexadecylpyridinium-Mo-blue (C16py-Mo-blue hybrid. The X-ray structure analysis revealed that C16py-H2Mo8 comprised β-type octamolybdate anion with two protons (β-H2Mo8. The β-H2Mo8 anions and ethanol molecules of crystallization formed two-dimensional anionic layers. The pyridine rings of C16py did not attend to form the two-dimensional inorganic layers, and the interdigitated C16py bilayers were sandwiched by the β-H2Mo8 anionic layers with periodicity of 18.2 Å. These C16py-H2Mo8 hybrid layered crystals possibly work as a new class of proton conductor.

  2. FGF4 and FGF8 comprise the wavefront activity that controls somitogenesis.

    Science.gov (United States)

    Naiche, L A; Holder, Nakisha; Lewandoski, Mark

    2011-03-08

    Somites form along the embryonic axis by sequential segmentation from the presomitic mesoderm (PSM) and differentiate into the segmented vertebral column as well as other unsegmented tissues. Somites are thought to form via the intersection of two activities known as the clock and the wavefront. Previous work has suggested that fibroblast growth factor (FGF) activity may be the wavefront signal, which maintains the PSM in an undifferentiated state. However, it is unclear which (if any) of the FGFs expressed in the PSM comprise this activity, as removal of any one gene is insufficient to disrupt early somitogenesis. Here we show that when both Fgf4 and Fgf8 are deleted in the PSM, expression of most PSM genes is absent, including cycling genes, WNT pathway genes, and markers of undifferentiated PSM. Significantly, markers of nascent somite cell fate expand throughout the PSM, demonstrating the premature differentiation of this entire tissue, a highly unusual phenotype indicative of the loss of wavefront activity. When WNT signaling is restored in mutants, PSM progenitor markers are partially restored but premature differentiation of the PSM still occurs, demonstrating that FGF signaling operates independently of WNT signaling. This study provides genetic evidence that FGFs are the wavefront signal and identifies the specific FGF ligands that encode this activity. Furthermore, these data show that FGF action maintains WNT signaling, and that both signaling pathways are required in parallel to maintain PSM progenitor tissue.

  3. Cercozoa comprises both EF-1α-containing and EFL-containing members.

    Science.gov (United States)

    Kamikawa, Ryoma; Yabuki, Akinori; Nakayama, Takuro; Ishida, Ken-ichiro; Hashimoto, Tetsuo; Inagaki, Yuji

    2011-01-01

    Elongation factor 1α (EF-1α) and elongation factor-like protein (EFL) are considered to be functionally equivalent proteins involved in peptide synthesis. Eukaryotes can be fundamentally divided into 'EF-1α-containing' and 'EFL-containing' types. Recently, EF-1α and EFL genes have been surveyed across the diversity of eukaryotes to explore the origin and evolution of EFL genes. Although the phylum Cercozoa is a diverse group, gene data for either EFL or EF-1α are absent from all cercozoans except chlorarachniophytes which were previously defined as EFL-containing members. Our survey revealed that two members of the cercozoan subphylum Filosa (Thaumatomastix sp. and strain YPF610) are EFL-containing members. Importantly, we identified EF-1α genes from two members of Filosa (Paracercomonas marina and Paulinella chromatophora) and a member of the other subphylum Endomyxa (Filoreta japonica). All cercozoan EFL homologues could not be recovered as a monophyletic group in maximum-likelihood and Bayesian analyses, suggesting that lateral gene transfer was involved in the EFL evolution in this protist assemblage. In contrast, EF-1α analysis successfully recovered a monophyly of three homologues sampled from the two cercozoan subphyla. Based on the results, we postulate that cercozoan EF-1α genes have been vertically inherited, and the current EFL-containing species may have secondarily lost their EF-1α genes.

  4. Pathology Residents Comprise Inspection Team for a CAP Self-Inspection.

    Science.gov (United States)

    Beal, Stacy G; Kresak, Jesse L; Yachnis, Anthony T

    2017-01-01

    We report our experience at the University of Florida in which residents and fellows served as the inspection team for a College of American Pathologists (CAP) self-inspection. We aimed to determine whether the CAP self-inspection could serve as a learning opportunity for pathology residents and fellows. To prepare for the inspection, we provided a series of 4 lunchtime seminars covering numerous laboratory management topics relating to inspections and laboratory quality. Preparation for the inspection began approximately 4 months prior to the date of the inspection. The intent was to simulate a CAP peer inspection, with the exception that the date was announced. The associate residency program director served as the team leader. All residents and fellows completed inspector training provided by CAP, and the team leader completed the team leader training. A 20 question pre- and posttest was administered; additionally, an anonymous survey was given after the inspection. The residents' and fellows' posttest scores were an average of 15% higher than on the pretest (P < .01). The surveys as well as subjective comments were overwhelmingly positive. In conclusion, the resident's and fellow's experience as an inspector during a CAP self-inspection was a useful tool to learn accreditation and laboratory management.

  5. Pathology Residents Comprise Inspection Team for a CAP Self-Inspection

    Directory of Open Access Journals (Sweden)

    Stacy G. Beal MD

    2017-03-01

    Full Text Available We report our experience at the University of Florida in which residents and fellows served as the inspection team for a College of American Pathologists (CAP self-inspection. We aimed to determine whether the CAP self-inspection could serve as a learning opportunity for pathology residents and fellows. To prepare for the inspection, we provided a series of 4 lunchtime seminars covering numerous laboratory management topics relating to inspections and laboratory quality. Preparation for the inspection began approximately 4 months prior to the date of the inspection. The intent was to simulate a CAP peer inspection, with the exception that the date was announced. The associate residency program director served as the team leader. All residents and fellows completed inspector training provided by CAP, and the team leader completed the team leader training. A 20 question pre- and posttest was administered; additionally, an anonymous survey was given after the inspection. The residents’ and fellows’ posttest scores were an average of 15% higher than on the pretest ( P < .01. The surveys as well as subjective comments were overwhelmingly positive. In conclusion, the resident’s and fellow’s experience as an inspector during a CAP self-inspection was a useful tool to learn accreditation and laboratory management.

  6. Instrument for measuring human biting force

    Science.gov (United States)

    Kopola, Harri K.; Mantyla, Olavi; Makiniemi, Matti; Mahonen, Kalevi; Virtanen, Kauko

    1995-02-01

    Alongside EMG activity, biting force is the primary parameter used for assessing the biting problems of dentulous patients and patients with dentures. In a highly conductive oral cavity, dielectric measurement methods are preferred, for safety reasons. The maximum biting force for patients with removable dentures is not more than 100 ... 300 N. We report here on an instrument developed for measuring human biting force which consists of three units: a mouthpiece, a signal processing and interface unit (SPI), and a PC. The mouthpiece comprises a sensor head of thickness 3.4 mm, width 20 mm and length 30 mm constructed of two stainless steel plates and with a fiber optic microbending sensor between them. This is connected to the SPI unit by a three-meter fiber optic cable, and the SPI unit to the PC by an RS connection. A computer program has been developed that includes measurement, display, zeroing, and calibration operations. The instrument measures biting force as a function of time and displays the time-dependent force profile and maximum force on a screen or plots it in hard copy. The dynamic measurement range of the mouthpiece is from 0 to 1000 N, and the resolution of the instrument is 10 N. The results of preliminary clinical measurements and repeatability tests are reported.

  7. Satisfaction measurement instruments for healthcare service users: a systematic review

    Directory of Open Access Journals (Sweden)

    Renato Santos de Almeida

    2015-01-01

    Full Text Available Patient satisfaction surveys can be an interesting way to improve quality and discuss the concept of patient-centered care. This study aimed to conduct a systematic review of the validated patient satisfaction measurement instruments applied in healthcare. The systematic review searched the MEDLINE/PubMed, LILACS, SciELO, Scopus and Web of Knowledge. The search strategy used the terms: "Patient Satisfaction" AND "Patient centered care" AND "Healthcare survey OR Satisfaction questionnaire" AND "Psychometric properties". 37 studies were included and almost all studies showed that satisfaction is a multidimensional construct. In these studies, 34 different instruments were used and most surveys contained the dimension patient-healthcare professional interactions, physical environment and management process. The COSMIN score for methodological quality showed that most of them scored a good or fair average. We can conclude that there is not a gold standard instrument for patient satisfaction assessment but some dimensions are essential for this construct.

  8. Preparation of salted meat products, e.g. cured bacon - by injecting liquid comprising meat proteins hydrolysed with enzymes

    DEFF Research Database (Denmark)

    1997-01-01

    Preparation of salted meat products comprises the following:(1) meat is chopped into fine pieces and mixed with water to form a slurry; (2) enzymes hydrolyse proteins in the meat; (3) adding a culture to the resulting medium, which comprises short peptide chains or amino acids; (4) forming...... flavourings as the culture is growing, and (5) injecting the liquid into pieces of meat....

  9. Preparation of salted meat products, e.g. cured bacon - by injecting liquid comprising meat proteins hydrolysed with enzymes

    DEFF Research Database (Denmark)

    1997-01-01

    Preparation of salted meat products comprises the following:(1) meat is chopped into fine pieces and mixed with water to form a slurry; (2) enzymes hydrolyse proteins in the meat; (3) adding a culture to the resulting medium, which comprises short peptide chains or amino acids; (4) forming...

  10. Tool – Material, Metaphor – Metonymy, Instrument(ness)

    DEFF Research Database (Denmark)

    Bertelsen, Olav Wedege; Breinbjerg, Morten; Pold, Søren

    2008-01-01

    This paper, presents in an abbreviated form the argument presented in an earlier paper[1], and tries to relate it to the theme, "retro in the interface". We introduce the concept instrumentness as a quality of human-computer interfaces. Instrumentness points to the way musical instruments are con...

  11. ZBLAN Viscosity Instrumentation

    Science.gov (United States)

    Kaukler, William

    2001-01-01

    The past year's contribution from Dr. Kaukler's experimental effort consists of these 5 parts: a) Construction and proof-of-concept testing of a novel shearing plate viscometer designed to produce small shear rates and operate at elevated temperatures; b) Preparing nonlinear polymeric materials to serve as standards of nonlinear Theological behavior; c) Measurements and evaluation of above materials for nonlinear rheometric behavior at room temperature using commercial spinning cone and plate viscometers available in the lab; d) Preparing specimens from various forms of pitch for quantitative comparative testing in a Dynamic Mechanical Analyzer, Thermal Mechanical Analyzer; and Archeological Analyzer; e) Arranging to have sets of pitch specimens tested using the various instruments listed above, from different manufacturers, to form a baseline of the viscosity variation with temperature using the different test modes offered by these instruments by compiling the data collected from the various test results. Our focus in this project is the shear thinning behavior of ZBLAN glass over a wide range of temperature. Experimentally, there are no standard techniques to perform such measurements on glasses, particularly at elevated temperatures. Literature reviews to date have shown that shear thinning in certain glasses appears to occur, but no data is available for ZBLAN glass. The best techniques to find shear thinning behavior require the application of very low rates of shear. In addition, because the onset of the thinning behavior occurs at an unknown elevated temperature, the instruments used in this study must provide controlled low rates of shear and do so for temperatures approaching 600 C. In this regard, a novel shearing parallel plate viscometer was designed and a prototype built and tested.

  12. An enhanced linkage map of the sheep genome comprising more than 1000 loci.

    Science.gov (United States)

    Maddox, J F; Davies, K P; Crawford, A M; Hulme, D J; Vaiman, D; Cribiu, E P; Freking, B A; Beh, K J; Cockett, N E; Kang, N; Riffkin, C D; Drinkwater, R; Moore, S S; Dodds, K G; Lumsden, J M; van Stijn, T C; Phua, S H; Adelson, D L; Burkin, H R; Broom, J E; Buitkamp, J; Cambridge, L; Cushwa, W T; Gerard, E; Galloway, S M; Harrison, B; Hawken, R J; Hiendleder, S; Henry, H M; Medrano, J F; Paterson, K A; Schibler, L; Stone, R T; van Hest, B

    2001-07-01

    A medium-density linkage map of the ovine genome has been developed. Marker data for 550 new loci were generated and merged with the previous sheep linkage map. The new map comprises 1093 markers representing 1062 unique loci (941 anonymous loci, 121 genes) and spans 3500 cM (sex-averaged) for the autosomes and 132 cM (female) on the X chromosome. There is an average spacing of 3.4 cM between autosomal loci and 8.3 cM between highly polymorphic [polymorphic information content (PIC) > or = 0.7] autosomal loci. The largest gap between markers is 32.5 cM, and the number of gaps of > 20 cM between loci, or regions where loci are missing from chromosome ends, has been reduced from 40 in the previous map to 6. Five hundred and seventy-three of the loci can be ordered on a framework map with odds of > 1000 : 1. The sheep linkage map contains strong links to both the cattle and goat maps. Five hundred and seventy-two of the loci positioned on the sheep linkage map have also been mapped by linkage analysis in cattle, and 209 of the loci mapped on the sheep linkage map have also been placed on the goat linkage map. Inspection of ruminant linkage maps indicates that the genomic coverage by the current sheep linkage map is comparable to that of the available cattle maps. The sheep map provides a valuable resource to the international sheep, cattle, and goat gene mapping community.

  13. Amyloid β Ion Channels in a Membrane Comprising Brain Total Lipid Extracts.

    Science.gov (United States)

    Lee, Joon; Kim, Young Hun; T Arce, Fernando; Gillman, Alan L; Jang, Hyunbum; Kagan, Bruce L; Nussinov, Ruth; Yang, Jerry; Lal, Ratnesh

    2017-02-20

    Amyloid β (Aβ) oligomers are the predominant toxic species in the pathology of Alzheimer's disease. The prevailing mechanism for toxicity by Aβ oligomers includes ionic homeostasis destabilization in neuronal cells by forming ion channels. These channel structures have been previously studied in model lipid bilayers. In order to gain further insight into the interaction of Aβ oligomers with natural membrane compositions, we have examined the structures and conductivities of Aβ oligomers in a membrane composed of brain total lipid extract (BTLE). We utilized two complementary techniques: atomic force microscopy (AFM) and black lipid membrane (BLM) electrical recording. Our results indicate that Aβ1-42 forms ion channel structures in BTLE membranes, accompanied by a heterogeneous population of ionic current fluctuations. Notably, the observed current events generated by Aβ1-42 peptides in BTLE membranes possess different characteristics compared to current events generated by the presence of Aβ1-42 in model membranes comprising a 1:1 mixture of DOPS and POPE lipids. Oligomers of the truncated Aβ fragment Aβ17-42 (p3) exhibited similar ion conductivity behavior as Aβ1-42 in BTLE membranes. However, the observed macroscopic ion flux across the BTLE membranes induced by Aβ1-42 pores was larger than for p3 pores. Our analysis of structure and conductance of oligomeric Aβ pores in a natural lipid membrane closely mimics the in vivo cellular environment suggesting that Aβ pores could potentially accelerate the loss of ionic homeostasis and cellular abnormalities. Hence, these pore structures may serve as a target for drug development and therapeutic strategies for AD treatment.

  14. Microvascular oxygen pressures in muscles comprised of different fiber types: Impact of dietary nitrate supplementation

    Science.gov (United States)

    Ferguson, Scott K.; Holdsworth, Clark T.; Wright, Jennifer L.; Fees, Alex J.; Allen, Jason D.; Jones, Andrew M.; Musch, Timothy I.; Poole, David C.

    2014-01-01

    Nitrate (NO3−) supplementation via beetroot juice (BR) preferentially improves vascular conductance and O2 delivery to contracting skeletal muscles comprised predominantly of type IIb + d/x (i.e. highly glycolytic) fibers following its reduction to nitrite and nitric oxide (NO). To address the mechanistic basis for NO3− to improve metabolic control we tested the hypothesis that increased NO bioavailability via BR supplementation would elevate microvascular PO2 (PO2mv) in fast twitch but not slow twitch muscle. Twelve young adult male Sprague-Dawley rats were administered BR ([NO3−] 1 mmol/kg/day, n=6) or water (control, n=6) for 5 days. PO2mv (phosphorescence quenching) was measured at rest and during 180s of electrically induced 1-Hz twitch contractions (6–8 V) of the soleus (9% type IIb +d/x) and mixed portion of the gastrocnemius (MG, 91% type IIb + d/x) muscles. In the MG, but not the soleus, BR elevated contracting steady state PO2mv by ~43% (control: 13.7 ± 0.5, BR: 19 ± 1.6 mmHg, (P<0.05). This higher PO2mv represents a greater blood-myocyte O2 driving force during muscle contractions thus providing a potential mechanism by which NO3− supplementation via BR improves metabolic control in fast twitch muscle. Recruitment of higher order type II muscle fibers is thought to play a role in the development of the V.O2 slow component which is inextricably linked to the fatigue process. These data therefore provide a putative mechanism for the BR-induced improvements in high-intensity exercise performance seen in humans. PMID:25280991

  15. The Histone Code of Toxoplasma gondii Comprises Conserved and Unique Posttranslational Modifications

    Science.gov (United States)

    Nardelli, Sheila C.; Che, Fa-Yun; Silmon de Monerri, Natalie C.; Xiao, Hui; Nieves, Edward; Madrid-Aliste, Carlos; Angel, Sergio O.; Sullivan, William J.; Angeletti, Ruth H.; Kim, Kami; Weiss, Louis M.

    2013-01-01

    ABSTRACT Epigenetic gene regulation has emerged as a major mechanism for gene regulation in all eukaryotes. Histones are small, basic proteins that constitute the major protein component of chromatin, and posttranslational modifications (PTM) of histones are essential for epigenetic gene regulation. The different combinations of histone PTM form the histone code for an organism, marking functional units of chromatin that recruit macromolecular complexes that govern chromatin structure and regulate gene expression. To characterize the repertoire of Toxoplasma gondii histone PTM, we enriched histones using standard acid extraction protocols and analyzed them with several complementary middle-down and bottom-up proteomic approaches with the high-resolution Orbitrap mass spectrometer using collision-induced dissociation (CID), higher-energy collisional dissociation (HCD), and/or electron transfer dissociation (ETD) fragmentation. We identified 249 peptides with unique combinations of PTM that comprise the T. gondii histone code. T. gondii histones share a high degree of sequence conservation with human histones, and many modifications are conserved between these species. In addition, T. gondii histones have unique modifications not previously identified in other species. Finally, T. gondii histones are modified by succinylation, propionylation, and formylation, recently described histone PTM that have not previously been identified in parasitic protozoa. The characterization of the T. gondii histone code will facilitate in-depth analysis of how epigenetic regulation affects gene expression in pathogenic apicomplexan parasites and identify a new model system for elucidating the biological functions of novel histone PTM. PMID:24327343

  16. Contiguous metal-mediated base pairs comprising two Ag(I) ions.

    Science.gov (United States)

    Megger, Dominik A; Guerra, Célia Fonseca; Hoffmann, Jan; Brutschy, Bernhard; Bickelhaupt, F Matthias; Müller, Jens

    2011-05-27

    The incorporation of transition-metal ions into nucleic acids by using metal-mediated base pairs has proved to be a promising strategy for the site-specific functionalization of these biomolecules. We report herein the formation of Ag(+)-mediated Hoogsteen-type base pairs comprising 1,3-dideaza-2'-deoxyadenosine and thymidine. By defunctionalizing the Watson-Crick edge of adenine, the formation of regular base pairs is prohibited. The additional substitution of the N3 nitrogen atom of adenine by a methine moiety increases the basicity of the exocyclic amino group. Hence, 1,3-dideazaadenine and thymine are able to incorporate two Ag(+) ions into their Hoogsteen-type base pair (as compared with one Ag(+) ion in base pairs with 1-deazaadenine and thymine). We show by using a combination of experimental techniques (UV and circular dichroism (CD) spectroscopies, dynamic light scattering, and mass spectrometry) that this type of base pair is compatible with different sequence contexts and can be used contiguously in DNA double helices. The most stable duplexes were observed when using a sequence containing alternating purine and pyrimidine nucleosides. Dispersion-corrected density functional theory calculations have been performed to provide insight into the structure, formation and stabilization of the twofold metalated base pair. They revealed that the metal ions within a base pair are separated by an Ag···Ag distance of about 2.88 Å. The Ag-Ag interaction contributes some 16 kcal mol(-1) to the overall stability of the doubly metal-mediated base pair, with the dominant contribution to the Ag-Ag bonding resulting from a donor-acceptor interaction between silver 4d-type and 4s orbitals. These Hoogsteen-type base pairs enable a higher functionalization of nucleic acids with metal ions than previously reported metal-mediated base pairs, thereby increasing the potential of DNA-based nanotechnology.

  17. Formation and structure of the first metal complexes comprising amidino-guanidinate ligands.

    Science.gov (United States)

    Sroor, Farid M; Liebing, Phil; Hrib, Cristian G; Gräsing, Daniel; Hilfert, Liane; Edelmann, Frank T

    2016-11-01

    The first metal complexes comprising amidino-guanidinate ligands have been prepared and structurally characterized, namely bis-[μ-N,N',N'',N'''-tetraisopropyl-1-(1-butyl-amidinato)guanidinato-κ(3)N(1),N(2):N(2)]bis-[(tetra-hydro-furan)lithium], [Li2(C18H37N4)2(C4H8O)2], (2), and [bis-(tetra-hydro-furan)-lithium]-di-μ-chlorido-{(N,N'-di-cyclo-hexyl-1-butyl-amidinato-κ(2)N(1),N(2))[N,N',N'',N'''-tetra-cyclo-hexyl-1-(1-butyl-amidinato)guanidinato-κ(2)N(1),N(2)]holmate(III)}, [HoLiCl2(C4H8O)2(C17H31N2)(C30H53N4)], (3). The novel lithium amidino-guanidinate precursors Li[ (n) BuC(=NR)(NR)C(NR)2] [1: R = Cy (cyclo-hex-yl), 2: R = (i) Pr) were obtained by treatment of N,N'-diorganocarbodi-imides, R-N=C=N-R (R = (i) Pr, Cy), with 0.5 equivalents of n-butyl-lithium under well-defined reaction conditions. An X-ray diffraction study of 2 revealed a ladder-type dimeric structure in the solid state. Reaction of anhydrous holmium(III) chloride with in situ-prepared 2 afforded the unexpected holmium 'ate' complex [ (n) BuC(=NCy)(NCy)C(NCy)2]Ho[ (n) BuC(NCy)2](μ-Cl)2Li(THF)2 (3) in 71% yield. An X-ray crystal structure determination of 3 showed that this complex contains both an amidinate ligand and the new amidino-guanidinate ligand.

  18. Formation and structure of the first metal complexes comprising amidinoguanidinate ligands

    Directory of Open Access Journals (Sweden)

    Farid M. Sroor

    2016-11-01

    Full Text Available The first metal complexes comprising amidinoguanidinate ligands have been prepared and structurally characterized, namely bis[μ-N,N′,N′′,N′′′-tetraisopropyl-1-(1-butylamidinatoguanidinato-κ3N1,N2:N2]bis[(tetrahydrofuranlithium], [Li2(C18H37N42(C4H8O2], (2, and [bis(tetrahydrofuranlithium]-di-μ-chlorido-{(N,N′-dicyclohexyl-1-butylamidinato-κ2N1,N2[N,N′,N′′,N′′′-tetracyclohexyl-1-(1-butylamidinatoguanidinato-κ2N1,N2]holmate(III}, [HoLiCl2(C4H8O2(C17H31N2(C30H53N4], (3. The novel lithium amidinoguanidinate precursors Li[nBuC(=NR(NRC(NR2] [1: R = Cy (cyclohexyl, 2: R = iPr were obtained by treatment of N,N′-diorganocarbodiimides, R—N=C=N—R (R = iPr, Cy, with 0.5 equivalents of n-butyllithium under well-defined reaction conditions. An X-ray diffraction study of 2 revealed a ladder-type dimeric structure in the solid state. Reaction of anhydrous holmium(III chloride with in situ-prepared 2 afforded the unexpected holmium `ate' complex [nBuC(=NCy(NCyC(NCy2]Ho[nBuC(NCy2](μ-Cl2Li(THF2 (3 in 71% yield. An X-ray crystal structure determination of 3 showed that this complex contains both an amidinate ligand and the new amidinoguanidinate ligand.

  19. Formation and structure of the first metal complexes comprising amidino­guanidinate ligands

    Science.gov (United States)

    Sroor, Farid M.; Liebing, Phil; Hrib, Cristian G.; Gräsing, Daniel; Hilfert, Liane; Edelmann, Frank T.

    2016-01-01

    The first metal complexes comprising amidino­guanidinate ligands have been prepared and structurally characterized, namely bis­[μ-N,N′,N′′,N′′′-tetraisopropyl-1-(1-butyl­amidinato)guanidinato-κ3 N 1,N 2:N 2]bis­[(tetra­hydro­furan)lithium], [Li2(C18H37N4)2(C4H8O)2], (2), and [bis­(tetra­hydro­furan)­lithium]-di-μ-chlorido-{(N,N′-di­cyclo­hexyl-1-butyl­amidinato-κ2 N 1,N 2)[N,N′,N′′,N′′′-tetra­cyclo­hexyl-1-(1-butyl­amidinato)guanidinato-κ2 N 1,N 2]holmate(III)}, [HoLiCl2(C4H8O)2(C17H31N2)(C30H53N4)], (3). The novel lithium amidino­guanidinate precursors Li[nBuC(=NR)(NR)C(NR)2] [1: R = Cy (cyclo­hex­yl), 2: R = iPr) were obtained by treatment of N,N′-diorganocarbodi­imides, R—N=C=N—R (R = iPr, Cy), with 0.5 equivalents of n-butyl­lithium under well-defined reaction conditions. An X-ray diffraction study of 2 revealed a ladder-type dimeric structure in the solid state. Reaction of anhydrous holmium(III) chloride with in situ-prepared 2 afforded the unexpected holmium ‘ate’ complex [nBuC(=NCy)(NCy)C(NCy)2]Ho[nBuC(NCy)2](μ-Cl)2Li(THF)2 (3) in 71% yield. An X-ray crystal structure determination of 3 showed that this complex contains both an amidinate ligand and the new amidino­guanidinate ligand. PMID:27840700

  20. Neuroplasticity in dynamic neural networks comprised of neurons attached to adaptive base plate.

    Science.gov (United States)

    Joghataie, Abdolreza; Shafiei Dizaji, Mehrdad

    2016-03-01

    In this paper, a learning algorithm is developed for Dynamic Plastic Continuous Neural Networks (DPCNNs) to improve their learning of highly nonlinear time dependent problems. A DPCNN is comprised of a base medium, which is nonlinear and plastic, and a number of neurons that are attached to the base by wire-like connections similar to perceptrons. The information is distributed within DPCNNs gradually and through wave propagation mechanism. While a DPCNN is adaptive due to its connection weights, the material properties of its base medium can also be adjusted to improve its learning. The material of the medium is plastic and can contribute to memorizing the history of input-response similar to neuroplasticity in natural brain. The results obtained from numerical simulation of DPCNNs have been encouraging. Nonlinear plastic finite element modeling has been used for numerical simulation of dynamic behavior and wave propagation in the medium. Two significant differences of DPCNNs with other types of neural networks are that: (1) there is a medium to which the neurons are attached where the medium can contribute to the learning, (2) the input layer is not made of nodes but it is an edge terminal which is capable of receiving a continuous function over the input edge, though it is discretized in the finite element model. A DPCNN is reduced to a perceptron if the medium is removed and the neurons are connected to each other only by wires. Continuity of the input lets the discretization of data take place intrinsically within the DPCNN instead of being applied by the user.

  1. Payment Instrument Characteristics

    DEFF Research Database (Denmark)

    Holst, Jacques; Kjeldsen, Martin; Hedman, Jonas;

    2015-01-01

    Over the last decade, we have witnessed payment innovations that fundamentally have changed the ways we pay. Payment innovations, such as mobile payments and on-line banking, include characteristics or features that are essential to understand if we want to know how and why payers choose among...... payment innovations. Using the Repertory Grid technique to explore 15 payers’ perception of six payment instruments, including coins, banknotes, debit cards, credit cards, mobile payments, and on-line banking, we identify 16 payment characteristics. The characteristics aggregate seventy-six unique...

  2. Beam Instrumentation and Diagnostics

    CERN Document Server

    Strehl, Peter

    2006-01-01

    This treatise covers all aspects of the design and the daily operations of a beam diagnostic system for a large particle accelerator. A very interdisciplinary field, it involves contributions from physicists, electrical and mechanical engineers and computer experts alike so as to satisfy the ever-increasing demands for beam parameter variability for a vast range of operation modi and particles. The author draws upon 40 years of research and work, most of them spent as the head of the beam diagnostics group at GSI. He has illustrated the more theoretical aspects with many real-life examples that will provide beam instrumentation designers with ideas and tools for their work.

  3. Pesticide reducing instruments

    DEFF Research Database (Denmark)

    Jacobsen, Lars-Bo; Jensen, Jørgen Dejgård; Andersen, Martin

    2005-01-01

    the cost and to calculate general economic and sectoral consequences. This CGE model is linked to an agricultural sector model calculating the optimal use of land, and the agricultural sector model is then linked to a biological agent based simulation model (ABM) calculating changes in the population...... for improving bio-diversity and securing drinking water. That is, combining economic modeling with physical biological modeling and geological evaluation allows us to select unsprayed field margins as the most effective instrument. Sensitivity analysis conducted on bio-diversity suggest that this result...

  4. Beam Instrument Development System

    Energy Technology Data Exchange (ETDEWEB)

    2016-01-08

    Beam Instrumentation Development System (BIDS) is a collection of common support libraries and modules developed during a series of Low-Level Radio Frequency (LLRF) control and timing/synchronization projects. BIDS includes a collection of Hardware Description Language (HDL) libraries and software libraries. The BIDS can be used for the development of any FPGA-based system, such as LLRF controllers. HDL code in this library is generic and supports common Digital Signal Processing (DSP) functions, FPGA-specific drivers (high-speed serial link wrappers, clock generation, etc.), ADC/DAC drivers, Ethernet MAC implementation, etc.

  5. Calibration of "Babyline" RP instruments

    CERN Multimedia

    2015-01-01

      If you have old RP instrumentation of the “Babyline” type, as shown in the photo, please contact the Radiation Protection Group (Joffrey Germa, 73171) to have the instrument checked and calibrated. Thank you. Radiation Protection Group

  6. Exoplanetary Science: Instrumentation, Observations, and Expectations

    Science.gov (United States)

    McElwain, Michael

    2011-01-01

    More than 700 exoplanets have been discovered and studied using indirect techniques, leading our field into the exciting new era of comparative exoplanetology. However, the direct detection of exoplanetary systems still remains at the sensitivity limits of both ground- and space-based observatories. The development of new technologies for adaptive optics systems and high contrast instruments continues to increase the ability to directly study exoplanets. The scientific impact of these developments has promising prospects for both short and long timescales. In my talk, I will discuss recent highlights from the SEEDS survey and the current instrumentation in use at the Subaru telescope. SEEDS is a high contrast imaging strategic observing program with 120 nights of time allocated at the NAOJ's flagship optical and infrared telescope. I will also describe new instrumentation I designed to improve the SEEDS capabilities and efficiency. Finally, I will briefly discuss the conceptual design of a transiting planet camera to fly as a potential second generation instrument on-board NASA's SOFIA observatory.

  7. Keyboard Emulation For Computerized Instrumentation

    Science.gov (United States)

    Wiegand, P. M.; Crouch, S. R.

    1989-01-01

    Keyboard emulator has interface at same level as manual keyboard entry. Since communication and control take place at high intelligence level in instrument, all instrument circuitry fully utilized. Little knowledge of instrument circuitry necessary, since only task interface performs is key closure. All existing logic and error checking still performed by instrument, minimizing workload of laboratory microcomputer. Timing constraints for interface operation minimal at keyboard entry level.

  8. TAIPAN instrument fibre positioner and Starbug robots: engineering overview

    Science.gov (United States)

    Staszak, Nicholas F.; Lawrence, Jon; Brown, David M.; Brown, Rebecca; Zhelem, Ross; Goodwin, Michael; Kuehn, Kyler; Lorente, Nuria P. F.; Nichani, Vijay; Waller, Lew; Case, Scott; Content, Robert; Hopkins, Andrew M.; Klauser, Urs; Pai, Naveen; Mueller, Rolf; Mali, Slavko; Vuong, Minh V.

    2016-07-01

    TAIPAN will conduct a stellar and galaxy survey of the Southern sky. The TAIPAN positioner is being developed as a prototype for the MANIFEST instrument on the GMT. The design for TAIPAN incorporates 150 optical fibres (with an upgrade path to 300) situated within independently controlled robotic positioners known as Starbugs. Starbugs allow precise parallel positioning of individual fibres, thus significantly reducing instrument configuration time and increasing the amount of observing time. Presented is an engineering overview of the UKST upgrade of the completely new Instrument Spider Assembly utilized to support the Starbug Fibre Positioning Robot and current status of the Starbug itself.

  9. Assessing Specific Sexual Behavior: Instrument Development and Validation Techniques.

    Science.gov (United States)

    Webb, Monica C; Chaney, J Don; Chen, W William; Dodd, Virginia J; Huang, I-Chan; Sanders, Sadie

    2015-02-01

    Through the use of multi-modal methods, the purpose of this study was to develop and assess measurement properties of an instrument evaluating specific sexual behaviors of college students and the role alcohol intoxication plays in one's intention to participate in these behaviors. A modified version of N. Krause's instrument development process was applied to create a behavior-specific instrument assessing oral, vaginal, and anal sex behaviors. The process included a review by expert scholars in relevant fields, cognitive interviews with the target population using screen-capture program Camtasia, piloting to assess measurement scales, and a formal investigation. The applied instrument development process employed screen capture software and web-based surveying in a cost-effective format suitable for mixed-method measurement development. The development and application of the instrument provides a clearer understanding of the relationship between alcohol use and sexual activity and aids in the development of effective public health interventions and policies.

  10. Advancements in Actuated Musical Instruments

    DEFF Research Database (Denmark)

    Overholt, Daniel; Berdahl, Edgar; Hamilton, Robert

    2011-01-01

    are physical instruments that have been endowed with virtual qualities controlled by a computer in real-time but which are nevertheless tangible. These instruments provide intuitive and engaging new forms of interaction. They are different from traditional (acoustic) and fully automated (robotic) instruments...

  11. Electronic Instruments -- Played or Used?

    Science.gov (United States)

    Ulveland, Randall Dana

    1998-01-01

    Compares the experience of playing an acoustic instrument to an electronic instrument by analyzing the constant structures and relationships between the experiences. Concludes that students' understanding of the physical experience of making music increases when experiences with acoustic instruments precede their exposure to electronic…

  12. Mallet Instruments Challenge Beginning Percussionists.

    Science.gov (United States)

    Grumley, Fred

    1983-01-01

    Orff mallet instruments should be used in beginning band classes. Adding mallet instruments would expand a beginner's concept of percussion instruments. Just as important, the percussion section would provide a solid melodic and harmonic foundation to assist beginning wind instrumentalists with their insecurities about pitch. (RM)

  13. An Instrumental Innovation

    Science.gov (United States)

    1978-01-01

    Think of guitars and you think of rock and country music, or the vigorous rhythms of the gypsy flamenco, or perhaps the classical strumming of a Segovia. About the last thing you would associate with guitars is aerospace technology. Yet there is a connection. A whole family of quality guitars is an outgrowth of helicopter rotor research conducted for the military services and NASA by an aerospace contractor. These musical spinoffs, commercially available and rapidly gaining in popularity, are the Ovation guitar line, manufactured by Ovation Instruments, Inc., Bloomfield, Connecticut. Ovation Instruments is a subsidiary of Kaman Corporation, a diversified company originally formed to develop and build helicopters. A helicopter's rotor system, with thousands of moving parts, is highly susceptible to vibration. For rotor efficiency, vibration must be "dampened," or reduced. Like other helicopter builders, Kaman Corporation spent years of research toward that end. The technology thus developed, together with the availability of staff experts in vibration engineering, sparked an idea in the mind of the company's president and founder, Charles H. Karnan. A guitarist of professional caliber, Kaman reasoned that vibration-dampening technology could be turned around to enhance vibration and thereby produce a guitar with superior sound.

  14. The QUIET Instrument

    Energy Technology Data Exchange (ETDEWEB)

    Bischoff, C.; et al.

    2012-07-01

    The Q/U Imaging ExperimenT (QUIET) is designed to measure polarization in the Cosmic Microwave Background, targeting the imprint of inflationary gravitational waves at large angular scales ({approx}1{sup o}). Between 2008 October and 2010 December, two independent receiver arrays were deployed sequentially on a 1.4m side-fed Dragonian telescope. The polarimeters which form the focal planes use a highly compact design based on High Electron Mobility Transistors (HEMTs) that provides simultaneous measurements of the Stokes parameters Q, U, and I in a single module. The 17-element Q-band polarimeter array, with a central frequency of 43.1 GHz, has the best sensitivity (69 {mu}Ks{sup 1/2}) and the lowest instrumental systematic errors ever achieved in this band, contributing to the tensor-to-scalar ratio at r < 0:1. The 84-element W-band polarimeter array has a sensitivity of 87 {mu}Ks{sup 1/2} at a central frequency of 94.5 GHz. It has the lowest systematic errors to date, contributing at r < 0:01. The two arrays together cover multipoles in the range {ell} {approx} 25 -- 975. These are the largest HEMT-based arrays deployed to date. This article describes the design, calibration, performance of, and sources of systematic error for the instrument.

  15. Balances instruments, manufacturers, history

    CERN Document Server

    Robens, Erich; Kiefer, Susanne

    2014-01-01

    The book deals mainly with direct mass determination by means of a conventional balances. It covers the history of the balance from the beginnings in Egypt earlier than 3000 BC to recent developments. All balance types are described with emphasis on scientific balances. Methods of indirect mass determination, which are applied to very light objects like molecules and the basic particles of matter and celestial bodies, are included.  As additional guidance, today’s manufacturers are listed and the profile of important companies is reviewed. Several hundred photographs, reproductions and drawings show instruments and their uses. This book includes commercial weighing instruments for merchandise and raw materials in workshops as well as symbolic weighing in the ancient Egyptian’s ceremony of ‘Weighing of the Heart’, the Greek fate balance, the Roman  Justitia, Juno Moneta and Middle Ages scenes of the Last Judgement with Jesus or St. Michael and of modern balances. The photographs are selected from the...

  16. Instrument Remote Control via the Astronomical Instrument Markup Language

    Science.gov (United States)

    Sall, Ken; Ames, Troy; Warsaw, Craig; Koons, Lisa; Shafer, Richard

    1998-01-01

    The Instrument Remote Control (IRC) project ongoing at NASA's Goddard Space Flight Center's (GSFC) Information Systems Center (ISC) supports NASA's mission by defining an adaptive intranet-based framework that provides robust interactive and distributed control and monitoring of remote instruments. An astronomical IRC architecture that combines the platform-independent processing capabilities of Java with the power of Extensible Markup Language (XML) to express hierarchical data in an equally platform-independent, as well as human readable manner, has been developed. This architecture is implemented using a variety of XML support tools and Application Programming Interfaces (API) written in Java. IRC will enable trusted astronomers from around the world to easily access infrared instruments (e.g., telescopes, cameras, and spectrometers) located in remote, inhospitable environments, such as the South Pole, a high Chilean mountaintop, or an airborne observatory aboard a Boeing 747. Using IRC's frameworks, an astronomer or other scientist can easily define the type of onboard instrument, control the instrument remotely, and return monitoring data all through the intranet. The Astronomical Instrument Markup Language (AIML) is the first implementation of the more general Instrument Markup Language (IML). The key aspects of our approach to instrument description and control applies to many domains, from medical instruments to machine assembly lines. The concepts behind AIML apply equally well to the description and control of instruments in general. IRC enables us to apply our techniques to several instruments, preferably from different observatories.

  17. Instrumentation for gamma-ray astronomy

    Science.gov (United States)

    Bertsch, David L.; Fichtel, Carl E.; Trombka, Jacob I.

    1988-01-01

    The current status of gamma-ray-telescope technology for ground, airborne, and space observations is surveyed and illustrated with drawings, diagrams, and graphs and tables of typical data. For the low- and medium-energy ranges, consideration is given to detectors and detector cooling systems, background-rejection methods, radiation damage, large-area detectors, gamma-ray imaging, data analysis, and the Compton-interaction region. Also discussed are the gamma-ray interaction process at high energies; multilevel automated spark-chamber gamma-ray telescopes; the Soviet Gamma-1 telescope; the EGRET instrument for the NASA Gamma-Ray Observatory; and Cerenkov, air-shower, and particle-detector instruments for the TeV and PeV ranges. Significant improvements in resolution and sensitivity are predicted for the near future.

  18. River Ice Data Instrumentation

    Science.gov (United States)

    1997-06-01

    edge in the field of ice engineering expands. For example, ice concentration and freezeup stage are not considered by the survey respondents to...im- pacts both freezeup and breakup jam formation Table 2. Ice parameters currently monitored, by Divisions (as of 1995). Ice parameters currently...V V V V Date of ice in V V V V Ice concentration V V V V Freezeup stage V V V V V Note: Southwestern Division does not currently monitor ice

  19. Control of microvascular oxygen pressures in rat muscles comprised of different fibre types

    Science.gov (United States)

    McDonough, Paul; Behnke, Brad J; Padilla, Danielle J; Musch, Timothy I; Poole, David C

    2005-01-01

    In response to an elevated metabolic rate , increased microvascular blood–muscle O2 flux is the product of both augmented O2 delivery and fractional O2 extraction. Whole body and exercising limb measurements demonstrate that and fractional O2 extraction increase as linear and hyperbolic functions, respectively, of . Given the presence of disparate vascular control mechanisms among different muscle fibre types, we tested the hypothesis that, in response to muscle contractions, would be lower and fractional O2 extraction (as assessed via microvascular O2 pressure, PmvO2) higher in fast- versus slow-twitch muscles. Radiolabelled microsphere and phosphorescence quenching techniques were used to measure and PmvO2, respectively at rest and across the transition to 1 Hz twitch contractions at low (Lo, 2.5 V) and high intensities (Hi, 4.5 V) in rat (n = 20) soleus (Sol, slow-twitch, type I), mixed gastrocnemius (MG, fast-twitch, type IIa) and white gastrocnemius (WG, fast-twitch, type IIb) muscle. At rest and for Lo and Hi (steady-state values) transitions, PmvO2 was lower (all P < 0.05) in MG (mmHg: rest, 22.5 ± 1.0; Lo, 15.3 ± 1.3; Hi, 10.2 ± 1.6) and WG (mmHg: rest, 19.0 ± 1.3; Lo, 12.2 ± 1.1; Hi, 9.9 ± 1.1) than in Sol (rest, 33.1 ± 3.2 mmHg; Lo, 19.0 ± 2.3 mmHg; Hi, 18.7 ± 1.8 mmHg), despite lower and in MG and WG under each set of conditions. These data suggest that during submaximal metabolic rates, the relationship between and O2 extraction is dependent on fibre type (at least in the muscles studied herein), such that muscles comprised of fast-twitch fibres display a greater fractional O2 extraction (i.e. lower PmvO2) than their slow-twitch counterparts. These results also indicate that the greater sustained PmvO2 in Sol may be important for ensuring high blood–myocyte O2 flux and therefore a greater oxidative contribution to energetic requirements. PMID:15637098

  20. Novel metabolic attributes of the genus cyanothece, comprising a group of unicellular nitrogen-fixing Cyanothece.

    Science.gov (United States)

    Bandyopadhyay, Anindita; Elvitigala, Thanura; Welsh, Eric; Stöckel, Jana; Liberton, Michelle; Min, Hongtao; Sherman, Louis A; Pakrasi, Himadri B

    2011-01-01

    The genus Cyanothece comprises unicellular cyanobacteria that are morphologically diverse and ecologically versatile. Studies over the last decade have established members of this genus to be important components of the marine ecosystem, contributing significantly to the nitrogen and carbon cycle. System-level studies of Cyanothece sp. ATCC 51142, a prototypic member of this group, revealed many interesting metabolic attributes. To identify the metabolic traits that define this class of cyanobacteria, five additional Cyanothece strains were sequenced to completion. The presence of a large, contiguous nitrogenase gene cluster and the ability to carry out aerobic nitrogen fixation distinguish Cyanothece as a genus of unicellular, aerobic nitrogen-fixing cyanobacteria. Cyanothece cells can create an anoxic intracellular environment at night, allowing oxygen-sensitive processes to take place in these oxygenic organisms. Large carbohydrate reserves accumulate in the cells during the day, ensuring sufficient energy for the processes that require the anoxic phase of the cells. Our study indicates that this genus maintains a plastic genome, incorporating new metabolic capabilities while simultaneously retaining archaic metabolic traits, a unique combination which provides the flexibility to adapt to various ecological and environmental conditions. Rearrangement of the nitrogenase cluster in Cyanothece sp. strain 7425 and the concomitant loss of its aerobic nitrogen-fixing ability suggest that a similar mechanism might have been at play in cyanobacterial strains that eventually lost their nitrogen-fixing ability. The unicellular cyanobacterial genus Cyanothece has significant roles in the nitrogen cycle in aquatic and terrestrial environments. Cyanothece sp. ATCC 51142 was extensively studied over the last decade and has emerged as an important model photosynthetic microbe for bioenergy production. To expand our understanding of the distinctive metabolic capabilities of

  1. Victimisation surveys: What are they good for?

    Directory of Open Access Journals (Sweden)

    Aromaa Kauko

    2012-01-01

    Full Text Available The author analyzes the usefulness of victimization surveys. The paper is focused of surveys in which nationally representative population samples are surveyed for their personal victimisation experiences, and their attitudes and opinions of issues related to crime and crime control. The author points out the benefits of using victimization surveys, but also explains why most countries have failed to make systematic use of this instrument.

  2. Managing skin and soft-tissue infection and nosocomial pneumonia caused by MRSA: a 2014 follow-up survey.

    Science.gov (United States)

    Dryden, Matthew; Andrasevic, Arjana Tambic; Bassetti, Matteo; Bouza, Emilio; Chastre, Jean; Baguneid, Mo; Esposito, Silvano; Giamarellou, Helen; Gyssens, Inge; Nathwani, Dilip; Unal, Serhat; Voss, Andreas; Wilcox, Mark

    2015-04-24

    As a follow-up to our 2009 survey, in order to explore opinion and practice on the epidemiology and management of meticillin-resistant Staphylococcus aureus (MRSA) in Europe, we conducted a second survey to elicit current opinions on this topic, particularly around antibiotic choice, dose, duration and route of administration. We also aimed to further understand how the management of MRSA has evolved in Europe during the past 5 years. Members of an expert panel of infectious diseases specialists convened in London (UK) in January 2014 to identify and discuss key issues in the management of MRSA. Following this meeting, a survey was developed comprising 36 questions covering a wide range of topics on MRSA complicated skin and soft-tissue infection and nosocomial pneumonia management. The survey instrument, a web-based questionnaire, was sent to the International Society of Chemotherapy for distribution to registered European infection societies and their members. This article reports the survey results from the European respondents. At the time of the original survey, the epidemiology of MRSA varied significantly across Europe and there were differing views on best practice. The current findings suggest that the epidemiology of healthcare-associated MRSA in Europe is, if anything, even more polarised, whilst community-acquired MRSA has become much more common. However, there now appears to be a much greater knowledge of current treatment/management options, and antimicrobial stewardship has moved forward considerably in the 5 years since the last survey.

  3. Media Lityeracy of Teachers: An Instrument for Assessing Their Competence

    Directory of Open Access Journals (Sweden)

    Vicent Gozálvez Pérez

    2014-10-01

    Full Text Available This article describes the process to elaborate and validate a survey that aims to identify and evaluate the media literacy level of non-university teachers.Currently, in a highly connected environment where media and communication technologies are increasingly relevant in the educational scope, it is essential to design an instrument that allows us to measure teachers media literacy level. This survey may support the enhancement of pedagogical proposals in order to improve teachers practice as well as teacher professional training. To validate the survey content, Delphi methodology was used by experts of seven Spanish universities. Converging validation has been done on the basis of a sample of 906 teachers from nine Spanish Autonomous Communities. The conclusion after survey psychometric analysis is that this instrument is adequate to measure media literacy level of non-university teachers.

  4. Back to Basics: Instrument Cleaning.

    Science.gov (United States)

    Spruce, Lisa

    2017-03-01

    Adequately cleaning and processing surgical instruments may be challenging for perioperative team members; however, the cleaning and processing of instruments are critical steps in making instruments safe to use on patients and achieving an appropriately safe OR environment. Instruments that are cleaned properly have had organic debris and soil removed, rendering them ready for sterilization or disinfection. This Back to Basics article covers the basic steps and considerations for cleaning and processing instruments before sterilization. Copyright © 2017 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  5. Potential Theory Surveys and Problems

    CERN Document Server

    Lukeš, Jaroslav; Netuka, Ivan; Veselý, Jiří

    1988-01-01

    The volume comprises eleven survey papers based on survey lectures delivered at the Conference in Prague in July 1987, which covered various facets of potential theory, including its applications in other areas. The survey papers deal with both classical and abstract potential theory and its relations to partial differential equations, stochastic processes and other branches such as numerical analysis and topology. A collection of problems from potential theory, compiled on the occasion of the conference, is included, with additional commentaries, in the second part of this volume.

  6. A Systematic Review of Student Self-Report Instruments That Assess Student-Teacher Relationships

    Science.gov (United States)

    Phillipo, Kate; Conner, Jerusha Osber; Davidson, Shannon; Pope, Denise

    2017-01-01

    Background: A large body of survey-based research asserts that the quality and strength of student-teacher relationships (STRs) predict a host of academic and nonacademic outcomes; however, advances in survey design research have led some to question existing survey instruments' psychometric soundness. Concurrently, qualitative research on STRs…

  7. Identifying Motor, Emotional–Behavioral, and Cognitive Deficits that Comprise the Triad of HD Symptoms from Patient, Caregiver, and Provider Perspectives

    Science.gov (United States)

    Victorson, David; Carlozzi, Noelle E.; Frank, Samuel; Beaumont, Jennifer L.; Cheng, Wendy; Gorin, Brian; Duh, Mei Sheng; Samuelson, David; Tulsky, David; Gutierrez, Sandra; Nowinski, Cindy J.; Mueller, Allison; Shen, Vivienne; Sung, Victor

    2014-01-01

    Background The objective of this study was to identify important attributes associated with the triad of symptoms (cognition, emotional–behavioral, and motor) of Huntington's disease (HD) from patient, caregiver, and medical provider perspectives to facilitate development of a new disease-specific, health-related quality of life (HRQOL) instrument. Methods We conducted a targeted literature review of HD and HRQOL instruments, expert surveys, and patient and caregiver phone-based interviews to extract information on the symptoms and issues most relevant to the HD symptom triad (HD triad). The data collected from these sources were used to generate themes and subdomains and to develop an integrated schema that highlights the key dimensions of the triad. Results The search identified the following areas: emotional functioning/behavioral changes (e.g., positive emotions, sadness/depression); cognitive functioning (e.g., memory/learning, attention/comprehension); physical functioning (e.g., motor functioning, medication); social functioning (e.g., leisure, interpersonal relationships); end-of-life concerns/planning; and gene testing. Fifteen individuals diagnosed with HD and 16 HD caregivers, recruited from several Huntington's Disease Society of America support group networks, completed phone interviews. Nineteen US medical providers who specialize in HD completed the online survey. Twenty-six subdomains of the HD symptom triad (seven cognition, 12 emotional–behavioral, and seven motor) emerged relatively consistently across patient, caregiver, and provider samples. These included movements/chorea, memory impairment, depression, and anxiety. Discussion Based on an integrated, mixed-methods approach, important HD triad symptom were identified and organized into a guiding schema. These patient-, caregiver-, and provider-triangulated data served as the basis for development of a HD-specific HRQOL instrument, the HD-PRO-TRIAD™. PMID:24757585

  8. Astronomical Instrumentation System Markup Language

    Science.gov (United States)

    Goldbaum, Jesse M.

    2016-05-01

    The Astronomical Instrumentation System Markup Language (AISML) is an Extensible Markup Language (XML) based file format for maintaining and exchanging information about astronomical instrumentation. The factors behind the need for an AISML are first discussed followed by the reasons why XML was chosen as the format. Next it's shown how XML also provides the framework for a more precise definition of an astronomical instrument and how these instruments can be combined to form an Astronomical Instrumentation System (AIS). AISML files for several instruments as well as one for a sample AIS are provided. The files demonstrate how AISML can be utilized for various tasks from web page generation and programming interface to instrument maintenance and quality management. The advantages of widespread adoption of AISML are discussed.

  9. Reconfigurable laser ranging instrument

    Science.gov (United States)

    Schneiter, John

    1994-03-01

    This paper describes the design and operation of a fast, flexible, non-contact, eye-safe laser ranging instrument useful in a variety of industrial metrology situations, such as in-process machining control and part inspection. The system has variable computer-controlled standoff and depth of field, and can obtain 3-D images of surfaces within a range of from 1.5 ft to almost 10 ft from the final optical element. The minimum depth of field is about 3.5 in. at 1.5 ft and about 26 in. at the far range. The largest depth of field for which useful data are available is about 41 in. Resolution, with appropriate averaging, is about one part in 4000 of the depth of field, which implies a best case resolution for this prototype of 0.00075 in. System flexibility is achieved by computer controlled relative positioning of optical components.

  10. Portable musical instrument amplifier

    Energy Technology Data Exchange (ETDEWEB)

    Christian, David E. (Danbury, CT)

    1990-07-24

    The present invention relates to a musical instrument amplifier which is particularly useful for electric guitars. The amplifier has a rigid body for housing both the electronic system for amplifying and processing signals from the guitar and the system's power supply. An input plug connected to and projecting from the body is electrically coupled to the signal amplifying and processing system. When the plug is inserted into an output jack for an electric guitar, the body is rigidly carried by the guitar, and the guitar is operatively connected to the electrical amplifying and signal processing system without use of a loose interconnection cable. The amplifier is provided with an output jack, into which headphones are plugged to receive amplified signals from the guitar. By eliminating the conventional interconnection cable, the amplifier of the present invention can be used by musicians with increased flexibility and greater freedom of movement.

  11. The MICE PID Instrumentation

    CERN Document Server

    Bonesini, M

    2008-01-01

    The international Muon Ionization Cooling Experiment (MICE) will carry out a systematic investigation of ionization cooling of a muon beam. As the emittance measurement will be done on a particle-by-particle basis, sophisticated beam instrumentation is needed to measure particle coordinates and timing vs RF. A PID system based on three time-of-flight stations, two Aerogel Cerenkov detectors and a KLOE-like calorimeter has been constructed in order to keep beam contamination ($e, \\pi$) well below 1%. The MICE time-of-flight system will measure timing with a resolution better than 70 ps per plane, in a harsh environment due to high particle rates, fringe magnetic fields and electron backgrounds from RF dark current.

  12. Instrumented Architectural Simulation System

    Science.gov (United States)

    Delagi, B. A.; Saraiya, N.; Nishimura, S.; Byrd, G.

    1987-01-01

    Simulation of systems at an architectural level can offer an effective way to study critical design choices if (1) the performance of the simulator is adequate to examine designs executing significant code bodies, not just toy problems or small application fragements, (2) the details of the simulation include the critical details of the design, (3) the view of the design presented by the simulator instrumentation leads to useful insights on the problems with the design, and (4) there is enough flexibility in the simulation system so that the asking of unplanned questions is not suppressed by the weight of the mechanics involved in making changes either in the design or its measurement. A simulation system with these goals is described together with the approach to its implementation. Its application to the study of a particular class of multiprocessor hardware system architectures is illustrated.

  13. Instrumented Pipeline Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Thomas Piro; Michael Ream

    2010-07-31

    This report summarizes technical progress achieved during the cooperative agreement between Concurrent Technologies Corporation (CTC) and U.S. Department of Energy to address the need for a for low-cost monitoring and inspection sensor system as identified in the Department of Energy (DOE) National Gas Infrastructure Research & Development (R&D) Delivery Reliability Program Roadmap.. The Instrumented Pipeline Initiative (IPI) achieved the objective by researching technologies for the monitoring of pipeline delivery integrity, through a ubiquitous network of sensors and controllers to detect and diagnose incipient defects, leaks, and failures. This report is organized by tasks as detailed in the Statement of Project Objectives (SOPO). The sections all state the objective and approach before detailing results of work.

  14. Ideology as instrument.

    Science.gov (United States)

    Glassman, Michael; Karno, Donna

    2007-12-01

    Comments on the article by J. T. Jost, which argued that the end-of-ideology claims that emerged in the aftermath of World War II were both incorrect and detrimental to the field of political psychology. M. Glassman and D. Karno make three critical points. First, Jost objectified ideology as a grand strategy implemented at the individual level, rather than as an instrument used for a specific purpose in activity. In doing so, he set ideology up as an "object" that guides human behavior rather than as a rational part of human experience. Second, they take issue with the idea that, because somebody acts in a manner that can be categorized as ideological, there actually is such a thing as ideology separate from that event and/or political experience and that psychologists ought to understand the meaning of ideology in order to understand future human activities as outside observers. Third, Jost seems to see this objective ideology as a unidirectional, causal mechanism for activity, a mechanism that assumes individuals act according to ideology, which eclipses the possibility that immediate ideological positions are the residue of purposeful activity. Glassman and Karno suggest that it may be better to take a pluralistic view of ideology in human action. Where ideology does exist, it is as a purposeful instrument--part of a logically based action to meet some ends-in-view--a mixture of immediate goals tied to secondary belief systems (which have been integrated to serve the material purposes of the purveyors of these ideologies). So if we are to understand ideology, we can only understand it through its use in human activity. (Copyright) 2007 APA.

  15. Aprendizaje instrumental en anfibios

    Directory of Open Access Journals (Sweden)

    Rubén N. Muzio

    1999-01-01

    Full Text Available Este trabajo presenta una revisión de los estudios realizados acerca de los mecanismos de aprendizaje en anfibios. Se conoce muy poco acerca de los procesos de aprendizaje en anfibios, y aún menos respecto de las relaciones cerebro-aprendizaje. Recientemente hemos comenzado el estudio sistemático del aprendizaje instrumental en el sapo Bufo arenarum dentro de un marco comparativo. Se observaron diversos fenómenos de aprendizaje comunes a una amplia variedad de vertebrados, tales como la adquisición bajo condiciones de entrenamiento masivo y espaciado, la extinción, la recuperación espontánea, el efecto subsiguiente al refuerzo, y el efecto en al adquisición de la magnitud del reforzamiento. Además, comenzamos el análisis de los efectos sobre el aprendizaje de las lesiones del pallium medial (estructura postulada como homóloga al hipocampo de los mamíferos. La lesión del paIlium medial no tuvo efectos sobre el desempeño ni sobre la tasa de captación de agua durante la adquisición. Pero retardó significativamente la extinción de la respuesta instrumental en un corredor recto. Estos datos sugieren que el palli um medial de los sapos juega un papel en la inhibición de respuestas previamente aprendidas. Los resultados de nuestros estudios en el sapo Bufo arenarum aportan datos origi na1es a la limitada información disponible sobre aprendizaje en anfibios.

  16. InstrumentationPod (IPOD) User Guide

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Robert F. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-06-12

    This document describes the Instrumentation Pod (IPOD) and its operation and use. The IPOD is a low-power detector system comprising a 3He tube with preamp for neutron detection, a microcontroller-based data acquisition system, a GPS receiver for locationdetermination and time-synchronization, and power filtering and protection. The IPOD is intended to be bolted to the top of Dual-Use Casks stored at Baikal-1 in Kazakhstan in order to maintain continuity of knowledge of the materials stored within the cask. The data acquisition system receives pulses from the neutron-detection preamp, combines this information with other sensor data, and stores the result on two SD cards that are part of the data acquisition system. Firmware in the data acquisition system controls collection and storing of the data and enables configuration of the acquisition parameters.

  17. Assessing the local windfield with instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Zambrano, T.G.

    1980-10-01

    This report concerns the development and testing of a technique for the initial screening and evaluation of potential sites for wind-energy conversion systems (WECS). The methodology was developed through a realistic siting exercise. The siting exercise involved measurements of winds along the surface and winds aloft using a relatively new instrument system, the Tethered Aerodynamic Lifting Anemometer (TALA) kite; notation of ecological factors such as vegetation flagging, soil erosion and site exposure, and verification of an area best suited for wind-energy development by establishing and maintaining a wind monitoring network. The siting exercise was carried out in an approximately 100-square-mile region of the Tehachapi Mountains of Southern California. The results showed that a comprehensive site survey involving field measurements, ecological survey, and wind-monitoring can be an effective tool for preliminary evaluation of WECS sites.

  18. Incidence of instrument separation using LightSpeed rotary instruments.

    Science.gov (United States)

    Knowles, Kenneth I; Hammond, Nathan B; Biggs, Stephen G; Ibarrola, Jose L

    2006-01-01

    The use of nickel-titanium rotary instrument systems has gained popularity over the past 10 years. One of these instrument systems is the LightSpeed (LightSpeed Technology, Inc, San Antonio, TX). One drawback for all nickel-titanium rotary instruments is the incidence of instrument separation. The purpose of this study was to evaluate the incidence of nonretrievable instrument separation using the LightSpeed system in a clinical setting. A total of 3543 canals were treated over a 24 month period and during that time, 46 LightSpeed instruments were separated and found to be nonretrievable, resulting in a separation rate of 1.30%. This rate was lower than previous reported studies.

  19. Tool – Material, Metaphor – Metonymy, Instrument(ness)

    DEFF Research Database (Denmark)

    Bertelsen, Olav Wedege; Breinbjerg, Morten; Pold, Søren

    2008-01-01

    This paper, presents in an abbreviated form the argument presented in an earlier paper[1], and tries to relate it to the theme, "retro in the interface". We introduce the concept instrumentness as a quality of human-computer interfaces. Instrumentness points to the way musical instruments are con...... pointing to alternative values, differing from traditional usability, which are also relevant in creative work outside art and music composition.......This paper, presents in an abbreviated form the argument presented in an earlier paper[1], and tries to relate it to the theme, "retro in the interface". We introduce the concept instrumentness as a quality of human-computer interfaces. Instrumentness points to the way musical instruments...... are controlled and conceptualized through values such as virtuosity and palyability, which are important for computer-mediated creative work supporting development in use beyond what is initially designed for. The papet performs a conceptual investigation into qualities in software interfaces that support...

  20. Student Engagement: Developing a Conceptual Framework and Survey Instrument

    Science.gov (United States)

    Burch, Gerald F.; Heller, Nathan A.; Burch, Jana J.; Freed, Rusty; Steed, Steve A.

    2015-01-01

    Student engagement is considered to be among the better predictors of learning, yet there is growing concern that there is no consensus on the conceptual foundation. The authors propose a conceptualization of student engagement grounded in A. W. Astin's (1984) Student Involvement Theory and W. A. Kahn's (1990) employee engagement research where…

  1. Student Engagement: Developing a Conceptual Framework and Survey Instrument

    Science.gov (United States)

    Burch, Gerald F.; Heller, Nathan A.; Burch, Jana J.; Freed, Rusty; Steed, Steve A.

    2015-01-01

    Student engagement is considered to be among the better predictors of learning, yet there is growing concern that there is no consensus on the conceptual foundation. The authors propose a conceptualization of student engagement grounded in A. W. Astin's (1984) Student Involvement Theory and W. A. Kahn's (1990) employee engagement research where…

  2. PEP surveying procedures and equipment

    Energy Technology Data Exchange (ETDEWEB)

    Linker, F.

    1982-06-01

    The PEP Survey and Alignment System, which employs both laser-based and optical survey methods, is described. The laser is operated in conjunction with the Tektronix 4051 computer and surveying instruments such as ARM and SAM, system which is designed to automate data input, reduction, and production of alignment instructions. The laser system is used when surveying ring quadrupoles, main bend magnets, sextupoles, and is optional when surveying RF cavities and insertion quadrupoles. Optical methods usually require that data be manually entered into the computer for alignment, but in some cases, an element can be aligned using nominal values of fiducial locations without use of the computer. Optical surveying is used in the alignment of NIT and SIT, low field bend magnets, wigglers, RF cavities, and insertion quadrupoles.

  3. Ex-core instrumentation; Instrumentation hors coeur des reacteurs

    Energy Technology Data Exchange (ETDEWEB)

    Burel, J.P. [Schneider Electric S.A., 92 - Boulogne-Billancourt (France)

    1999-01-01

    The safety and the control of the reactor need to master the nuclear power from the core radiation measurement. According to the reactor dimensions and conception, the nuclear parameters monitoring is realized through two instrumentation systems: the ex-core instrumentation system which use detector placed outside of the core and the in-core instrumentation system. This paper deals with the ex-core systems based on neutronic measurements and details the detectors choice, the treatment circuits, data processing, realizations in France and also example of the Wwr reactor instrumentation. (A.L.B.)

  4. Industrial instrumentation principles and design

    CERN Document Server

    Padmanabhan, Tattamangalam R

    2000-01-01

    Pneumatic, hydraulic and allied instrumentation schemes have given way to electronic schemes in recent years thanks to the rapid strides in electronics and allied areas. Principles, design and applications of such state-of-the-art instrumentation schemes form the subject matter of this book. Through representative examples, the basic building blocks of instrumentation schemes are identified and each of these building blocks discussed in terms of its design and interface characteristics. The common generic schemes synthesized with such building blocks are dealt with subsequently. This forms the scope of Part I. The focus in Part II is on application. Displacement and allied instrumentation, force and allied instrumentation and process instrumentation in terms of temperature, flow, pressure level and other common process variables are dealt with separately and exhaustively. Despite the diversity in the sensor principles and characteristics and the variety in the applications and their environments, it is possib...

  5. Instruments to assess integrated care

    DEFF Research Database (Denmark)

    Lyngsø, Anne Marie; Godtfredsen, Nina Skavlan; Høst, Dorte

    2014-01-01

    abstracts were independently reviewed by two investigators. RESULTS: We identified 23 measurement instruments and, within these, eight organisational elements were found. No measurement instrument covered all organisational elements, but almost all studies include well-defined structural and process aspects......INTRODUCTION: Although several measurement instruments have been developed to measure the level of integrated health care delivery, no standardised, validated instrument exists covering all aspects of integrated care. The purpose of this review is to identify the instruments concerning how...... to measure the level of integration across health-care sectors and to assess and evaluate the organisational elements within the instruments identified. METHODS: An extensive, systematic literature review in PubMed, CINAHL, PsycINFO, Cochrane Library, Web of Science for the years 1980-2011. Selected...

  6. An Examination of Secondary Wind Instrument Methods Courses

    Science.gov (United States)

    Wagoner, Cynthia L.; Juchniewicz, Jay

    2017-01-01

    The purpose of this study was to investigate current secondary woodwind, brass, and combined wind instrument methods courses for preservice music teachers across the United States. Two-hundred eleven (N = 211) wind methods course instructors from National Association of Schools of Music-accredited institutions completed an online survey that…

  7. Effect of Sex Identification on Instrument Assignment by Band Directors

    Science.gov (United States)

    Johnson, Christopher M.; Stewart, Erin E.

    2004-01-01

    The purpose of this study was to investigate the effect of sex identification on the assignment of instruments to beginning band students. Participants were band directors solicited at music conferences and music education students solicited from major universities across the United States. Participants completed an online survey about instrument…

  8. Detectors for Tomorrow's Instruments

    Science.gov (United States)

    Moseley, Harvey

    2009-01-01

    Cryogenically cooled superconducting detectors have become essential tools for a wide range of measurement applications, ranging from quantum limited heterodyne detection in the millimeter range to direct searches for dark matter with superconducting phonon detectors operating at 20 mK. Superconducting detectors have several fundamental and practical advantages which have resulted in their rapid adoption by experimenters. Their excellent performance arises in part from reductions in noise resulting from their low operating temperatures, but unique superconducting properties provide a wide range of mechanisms for detection. For example, the steep dependence of resistance with temperature on the superconductor/normal transition provides a sensitive thermometer for calorimetric and bolometric applications. Parametric changes in the properties of superconducting resonators provides a mechanism for high sensitivity detection of submillimeter photons. From a practical point of view, the use of superconducting detectors has grown rapidly because many of these devices couple well to SQUID amplifiers, which are easily integrated with the detectors. These SQUID-based amplifiers and multiplexers have matured with the detectors; they are convenient to use, and have excellent noise performance. The first generation of fully integrated large scale superconducting detection systems are now being deployed. I will discuss the prospects for a new generation of instruments designed to take full advantage of the revolution in detector technology.

  9. The Clementine instrument complement

    Science.gov (United States)

    Lucey, Paul G.

    1993-01-01

    The recent successes of the Galileo solid-state imaging (SSI) experiment at the Moon and Gaspra show the utility of multispectral imaging of planetary objects. 'Clementine' is the planetary community's 'code name' for the SDIO (Space Defense Initiative Organization), mission to the Moon and the asteroid Geographos. This mission is designed as a long term stressing test on sensors and space systems developed for SDIO. In the course of this test Clementine will obtain science data using a varied and powerful array of remote sensing instruments which were developed by or for Lawrence Livermore National Laboratory in Livermore, California. Clementine carries five cameras, one for navigation and four for science experiments. In addition, a laser ranger is included which will serve as a laser altimeter. The Clementine cameras cover a wider range of spatial resolutions and wavelength range than did Galileo and are almost ideally suited to mapping of mafic rock types as are present on the Moon and expected at Geographos. Calibration of the cameras will occur at the sensor calibration laboratory at LLNL. In flight calibrations, using standard stars and other standards should improve the stated accuracies. Signal-to-noise ratios (SNRs) include the following noise sources: shot noise, calibration error, digitization noise, readout noise, and frame transfer noise (where applicable). The achieved SNRs are a balance between detector saturation and acceptable image smear. The 'worst' case uses the longest possible integration times.

  10. Impact Disdrometers Instrument Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Bartholomew, Mary Jane [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-03-01

    To improve the quantitative description of precipitation processes in climate models, the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Climate Research Facility has been collecting observations of the drop size spectra of rain events since early in 2006. Impact disdrometers were the initial choice due to their reliability, ease of maintenance, and relatively low cost. Each of the two units deployed was accompanied by a nearby tipping bucket. In 2010, the tipping buckets were replaced by weighing buckets rain gauges. Five video disdrometers were subsequently purchased and are described in ARM’s VDIS Handbook.1 As of April 2011, three of the weighing bucket instruments were deployed, one was to travel with the second ARM Mobile Facility, and the fifth was a spare. Two of the video disdrometers were deployed, a third was to be deployed later in the spring of 2011, one was to travel with the second ARM Mobile Facility, and the last was a spare. Detailed descriptions of impact disdrometers and their datastreams are provided in this document.

  11. Halo vest instrumentation

    Science.gov (United States)

    Huston, Dryver R.; Krag, Martin

    1996-05-01

    The halo vest is a head and neck immobilization system that is often used on patients that are recovering from cervical trauma or surgery. The halo vest system consists of a rigid halo that is firmly attached to the skull, an upright support structure for stabilization and immobilization, and a torso-enveloping vest. The main purpose of this study was to measure the forces that are carried by the halo-vest structure as the subject undergoes various activities of daily living and external loading for different vest designs. A tethered strain gage load cell based instrumentation system was used to take these load measurements on ten different subjects. Three different halo-vest systems were evaluated. The primary difference between the vests was the amount of torso coverage and the use of shoulder straps. The loads were measured, analyzed and used to compare the vests and to create a model of halo-vest-neck mechanics. Future applications of this technology to standalone data logging, pin-load measuring and biofeedback applications are discussed.

  12. Language as an instrument of thought

    Directory of Open Access Journals (Sweden)

    Eran Asoulin

    2016-11-01

    Full Text Available I show that there are good arguments and evidence to boot that support the language as an instrument of thought hypothesis. The underlying mechanisms of language, comprising of expressions structured hierarchically and recursively, provide a perspective (in the form of a conceptual structure on the world, for it is only via language that certain perspectives are available to us and to our thought processes. These mechanisms provide us with a uniquely human way of thinking and talking about the world that is different to the sort of thinking we share with other animals. If the primary function of language were communication then one would expect that the underlying mechanisms of language will be structured in a way that favours successful communication. I show that not only is this not the case, but that the underlying mechanisms of language are in fact structured in a way to maximise computational efficiency, even if it means causing communicative problems. Moreover, I discuss evidence from comparative, neuropathological, developmental, and neuroscientific evidence that supports the claim that language is an instrument of thought.

  13. Microfabricated instrument for tissue biopsy and analysis

    Science.gov (United States)

    Krulevitch, Peter A.; Lee, Abraham P.; Northrup, M. Allen; Benett, William J.

    1999-01-01

    A microfabricated biopsy/histology instrument which has several advantages over the conventional procedures, including minimal specimen handling, smooth cutting edges with atomic sharpness capable of slicing very thin specimens (approximately 2 .mu.m or greater), micro-liter volumes of chemicals for treating the specimens, low cost, disposable, fabrication process which renders sterile parts, and ease of use. The cutter is a "cheese-grater" style design comprising a block or substrate of silicon and which uses anisotropic etching of the silicon to form extremely sharp and precise cutting edges. As a specimen is cut, it passes through the silicon cutter and lies flat on a piece of glass which is bonded to the cutter. Microchannels are etched into the glass or silicon substrates for delivering small volumes of chemicals for treating the specimen. After treatment, the specimens can be examined through the glass substrate. For automation purposes, microvalves and micropumps may be incorporated. Also, specimens in parallel may be cut and treated with identical or varied chemicals. The instrument is disposable due to its low cost and thus could replace current expensive microtome and histology equipment.

  14. Measurement, instrumentation, and sensors handbook

    CERN Document Server

    Eren, Halit

    2014-01-01

    The Second Edition of the bestselling Measurement, Instrumentation, and Sensors Handbook brings together all aspects of the design and implementation of measurement, instrumentation, and sensors. Reflecting the current state of the art, it describes the use of instruments and techniques for performing practical measurements in engineering, physics, chemistry, and the life sciences and discusses processing systems, automatic data acquisition, reduction and analysis, operation characteristics, accuracy, errors, calibrations, and the incorporation of standards for control purposes. Organized acco

  15. Experimenting with string musical instruments

    Science.gov (United States)

    LoPresto, Michael C.

    2012-03-01

    What follows are several investigations involving string musical instruments developed for and used in a Science of Sound & Light course. The experiments make use of a guitar, orchestral string instruments and data collection and graphing software. They are designed to provide students with concrete examples of how mathematical formulae, when used in physics, represent reality that can actually be observed, in this case, the operation of string musical instruments.

  16. Logical Varieties of Instrumental Reasons

    OpenAIRE

    Spielthenner, Georg

    2012-01-01

    Instrumental reasons play a central role in our practical deliberations because we apply the distinction between reasonable and unreasonable not only to beliefs, but to actions also. The question of what one has an instrumental reason to do is an important substantive question that is relevant to the general theory of practical reasoning and to ethics, too. It will be my object in the present study to show that we have different kinds of instrumental reasons, which depend solely on their logi...

  17. Status of ART-XC/SRG Instrument

    Science.gov (United States)

    Pavlinsky, M.; Akimov, V.; Levin, V.; Lapshov, I.; Tkachenko, A.; Semena, N.; Buntov, M.; Glushenko, A.; Arefiev, V.; Yaskovich, A.; Sunyaev, R.; Churazov, E.; Gilfanov, M.; Grebenev, S.; Sazonov, S.; Revnivtsev, M.; Lutovinov, A.; Molkov, S.; Kudelin, M.; Drozdova, T.; Garanin, S.; Grigorovich, S.; Litvin, D.; Lazarchuk, V.; Roiz, I.; Garin, M.; Babyshkin, V.; Lomakin, I.; Menderov, A.; Moskvinov, D.; Gubarev, M.; Ramsey, B.; Kilaru, K.; ODell, S. L.; Kolodziejczak, J.; Elsner, R.

    2014-01-01

    Spectrum Roentgen Gamma (SRG) is an X-ray astrophysical observatory, developed by Russia in collaboration with Germany. The mission will be launched in March 2016 from Baikonur, by a Zenit rocket with a Fregat booster and placed in a 6-month-period halo orbit around L2. The scientific payload consists of two independent telescopes - a soft-x-ray survey instrument, eROSITA, being provided by Germany and a medium-x-ray-energy survey instrument ART-XC being developed by Russia. ART-XC will consist of seven independent, but co-aligned, telescope modules. The NASA Marshall Space Flight Center (MSFC) is fabricating the flight mirror modules for the ART-XC/SRG. Each mirror module will be aligned with a focal plane CdTe double-sided strip detectors which will operate over the energy range of 6-30 keV, with an angular resolution of less than 1', a field of view of approximately 34' and an expected energy resolution of about 10 percent at 14 keV.

  18. Smart focal plane technologies for ELT instruments

    Science.gov (United States)

    Cunningham, Colin R.; Ramsay-Howat, Suzanne K.; Garzon, Francisco; Parry, Ian R.; Prieto, Eric; Robertson, David J.; Zamkotsian, Frederic

    2004-07-01

    Smart Focal Planes are devices that enable the efficient sampling of a telescope's focal plane to feed spectroscopic and imaging instruments. Examples are integral field units (fiber and image slicers), cryogenic beam manipulators, and MOEMS (micro-opto-electromechanical systems) such as miniature slit shutters. These technologies are critical in making best use of the current 8m class telescopes for key science goals such as spectroscopic surveys of high redshift galaxies, and will be even more important for Extremely Large Telescope (ELT) instruments. In fact, the density of pixels in an ELT focal plane with several milliarcsecond resolution will mean that sub-sampling of the field will be needed even for imaging. We have proposed a joint European project to develop these technologies, building on expertise from partners in the UK, France, the Netherlands, Spain, Germany and others, and led by the UK. We describe the current status of these technologies, showing how they will contribute to the feasibility and performance of proposed instruments for ELTs, and concentrating on capabilities within Europe. We then outline the proposed future developments, highlighting the technical challenges, such as the difficulties of manufacturing and verifying complex image slicers with thousands of optical surfaces, and building highly reliable cryogenic mechanisms such as pick-off arms, beam steering mirrors and reconfigurble slit mechanisms.

  19. "Suntelligence" Survey

    Science.gov (United States)

    ... to the American Academy of Dermatology's "Suntelligence" sun-smart survey. Please answer the following questions to measure ... be able to view a ranking of major cities suntelligence based on residents' responses to this survey. ...

  20. CARMENES instrument control system and operational scheduler

    Science.gov (United States)

    Garcia-Piquer, Alvaro; Guàrdia, Josep; Colomé, Josep; Ribas, Ignasi; Gesa, Lluis; Morales, Juan Carlos; Pérez-Calpena, Ana; Seifert, Walter; Quirrenbach, Andreas; Amado, Pedro J.; Caballero, José A.; Reiners, Ansgar

    2014-07-01

    The main goal of the CARMENES instrument is to perform high-accuracy measurements of stellar radial velocities (1m/s) with long-term stability. CARMENES will be installed in 2015 at the 3.5 m telescope in the Calar Alto Observatory (Spain) and it will be equipped with two spectrographs covering from the visible to the near-infrared. It will make use of its near-IR capabilities to observe late-type stars, whose peak of the spectral energy distribution falls in the relevant wavelength interval. The technology needed to develop this instrument represents a challenge at all levels. We present two software packages that play a key role in the control layer for an efficient operation of the instrument: the Instrument Control System (ICS) and the Operational Scheduler. The coordination and management of CARMENES is handled by the ICS, which is responsible for carrying out the operations of the different subsystems providing a tool to operate the instrument in an integrated manner from low to high user interaction level. The ICS interacts with the following subsystems: the near-IR and visible channels, composed by the detectors and exposure meters; the calibration units; the environment sensors; the front-end electronics; the acquisition and guiding module; the interfaces with telescope and dome; and, finally, the software subsystems for operational scheduling of tasks, data processing, and data archiving. We describe the ICS software design, which implements the CARMENES operational design and is planned to be integrated in the instrument by the end of 2014. The CARMENES operational scheduler is the second key element in the control layer described in this contribution. It is the main actor in the translation of the survey strategy into a detailed schedule for the achievement of the optimization goals. The scheduler is based on Artificial Intelligence techniques and computes the survey planning by combining the static constraints that are known a priori (i.e., target

  1. Towards automatic musical instrument timbre recognition

    Science.gov (United States)

    Park, Tae Hong

    This dissertation is comprised of two parts---focus on issues concerning research and development of an artificial system for automatic musical instrument timbre recognition and musical compositions. The technical part of the essay includes a detailed record of developed and implemented algorithms for feature extraction and pattern recognition. A review of existing literature introducing historical aspects surrounding timbre research, problems associated with a number of timbre definitions, and highlights of selected research activities that have had significant impact in this field are also included. The developed timbre recognition system follows a bottom-up, data-driven model that includes a pre-processing module, feature extraction module, and a RBF/EBF (Radial/Elliptical Basis Function) neural network-based pattern recognition module. 829 monophonic samples from 12 instruments have been chosen from the Peter Siedlaczek library (Best Service) and other samples from the Internet and personal collections. Significant emphasis has been put on feature extraction development and testing to achieve robust and consistent feature vectors that are eventually passed to the neural network module. In order to avoid a garbage-in-garbage-out (GIGO) trap and improve generality, extra care was taken in designing and testing the developed algorithms using various dynamics, different playing techniques, and a variety of pitches for each instrument with inclusion of attack and steady-state portions of a signal. Most of the research and development was conducted in Matlab. The compositional part of the essay includes brief introductions to "A d'Ess Are ," "Aboji," "48 13 N, 16 20 O," and "pH-SQ." A general outline pertaining to the ideas and concepts behind the architectural designs of the pieces including formal structures, time structures, orchestration methods, and pitch structures are also presented.

  2. Design of Onboard Instrument Based on Virtual Instrument Technology

    Institute of Scientific and Technical Information of China (English)

    TANG Baoping; ZHONG Yuanchang; QIU Jianwei

    2006-01-01

    After analyzing and comparing the traditional automobile instrument, the onboard instrument based on virtual instrument technology is designed in this paper. The PC/104 computer was employed as the core processing unit of the onboard instrument, and the several intelligent data acquisition nodes are set and connected by the CAN bus, through which the nodes can communicate with the core processing unit. The information of the vehicle's working condition can be displayed synthetically by adopting virtual instrument technology. When the working condition goes beyond its limit, the system can emit an alarm, record and storage the abnormal condition automatically, and suggest how to deal with the abnormity urgently. The development background and design idea of onboard information system were elaborated in the paper. The software, the hardware architecture and the principle of onboard information system were introduced in detail.

  3. Survey Says

    Science.gov (United States)

    McCarthy, Susan K.

    2005-01-01

    Survey Says is a lesson plan designed to teach college students how to access Internet resources for valid data related to the sexual health of young people. Discussion questions based on the most recent available data from two national surveys, the Youth Risk Behavior Surveillance-United States, 2003 (CDC, 2004) and the National Survey of…

  4. The Prospects of Musical Instruments For People with Physical Disabilities

    DEFF Research Database (Denmark)

    Larsen, Jeppe Veirum; Overholt, Daniel; Moeslund, Thomas B.

    2016-01-01

    Many forms of enabling technologies exist today. While technologies aimed at enabling basic tasks in everyday life (locomotion, eating, etc.) are more common, musical instruments for people with disabilities can provide a chance for emotional enjoyment, as well as improve physical conditions...... through therapeutic use. The field of musical instruments for people with physical disabilities, however, is still an emerging area of research. In this article, we look at the current state of developments, including a survey of custom designed instruments, augmentations / modifications of existing...... instruments, music-supported therapy, and recent trends in the area. The overview is extrapolated to look at where the research is headed, providing insights for potential future work....

  5. The Prospects of Musical Instruments For People with Physical Disabilities

    DEFF Research Database (Denmark)

    Larsen, Jeppe Veirum; Overholt, Daniel; Moeslund, Thomas B.

    2016-01-01

    Many forms of enabling technologies exist today. While technologies aimed at enabling basic tasks in everyday life (locomotion, eating, etc.) are more common, musical instruments for people with disabilities can provide a chance for emotional enjoyment, as well as improve physical conditions...... through therapeutic use. The field of musical instruments for people with physical disabilities, however, is still an emerging area of research. In this article, we look at the current state of developments, including a survey of custom designed instruments, augmentations / modifications of existing...... instruments, music-supported therapy, and recent trends in the area. The overview is extrapolated to look at where the research is headed, providing insights for potential future work....

  6. The development and testing of the nurses' cardiac triage instrument.

    Science.gov (United States)

    Arslanian-Engoren, Cynthia; Hagerty, Bonnie M

    2013-01-01

    Rapid recognition and treatment of myocardial infarction (MI) reduces morbidity and mortality. Although emergency department (ED) nurses are often the first provider to evaluate individuals and are in a prime position to initiate MI guideline recommendations, no valid and reliable instrument was found to quantify their decision-making processes. The purpose of this study was to develop and test the psychometric properties of a new theoretically driven, empirically based instrument for measuring nurses' cardiac triage decisions. Using a descriptive research design, data were collected using a mailed survey. There were 158 ED nurses who completed a mailed questionnaire. Factor analysis revealed three factors (patient presentation, unbiased nurse reasoning process, and nurse action) with good internal consistency (Cronbach's alpha = .903, .809, .718) and sample adequacy (KMO = .758) of the 30-item instrument. The newly developed instrument has the potential to improve patient outcomes surrounding early MI identification and treatment.

  7. Youth Gangs: Experience from a Pilot Survey

    Science.gov (United States)

    Salagaev, A. L.; Shashkin, A. V.

    2005-01-01

    The present article is based on the results of an expert survey and a survey of young people in the schools of two Russian cities, Moscow and Kazan (2003). The study focused on making the research problem more explicit and testing the set of instruments, which was developed with the authors' participation in the framework of the Eurogang research…

  8. Self-composite comprised of nanocrystalline diamond and a non-diamond component useful for thermoelectric applications

    Science.gov (United States)

    Gruen, Dieter M.

    2009-08-11

    One provides nanocrystalline diamond material that comprises a plurality of substantially ordered diamond crystallites that are sized no larger than about 10 nanometers. One then disposes a non-diamond component within the nanocrystalline diamond material. By one approach this non-diamond component comprises an electrical conductor that is formed at the grain boundaries that separate the diamond crystallites from one another. The resultant nanowire is then able to exhibit a desired increase with respect to its ability to conduct electricity while also preserving the thermal conductivity behavior of the nanocrystalline diamond material.

  9. Control valve and control valve system for controlling solids flow, methods of manufacture thereof and articles comprising the same

    Energy Technology Data Exchange (ETDEWEB)

    Jukkola, Glen D.; Teigen, Bard C.

    2017-04-11

    Disclosed herein is a solids flow control valve comprising a standpipe; a shoe; and a transport pipe; wherein the standpipe is in operative communication with the shoe and lies upstream of the shoe; the standpipe comprising a first end and a second end, where the first end is in contact with a source that contains disposable solids and the second end is in fluid contact with the shoe; the shoe being operative to restrict the flow of the disposable solids; the transport pipe being disposed downstream of the shoe to receive and transport the solids from the shoe.

  10. Formación instrumental

    Directory of Open Access Journals (Sweden)

    Darío Zerrate

    2008-09-01

    Full Text Available Es el nombre dado al proyecto de investigación que un Grupo de docentes del Énfasis de Pedagogía Instrumental del Departamento de Educación Musical de la Facultad de BELLAS ARTES, propone para reflexionar sobre la Didáctica Instrumental

  11. Cryogenic Caging for Science Instrumentation

    Science.gov (United States)

    Penanen, Konstantin; Chui, Talso C.

    2011-01-01

    A method has been developed for caging science instrumentation to protect from pyro-shock and EDL (entry, descent, and landing) acceleration damage. Caging can be achieved by immersing the instrument (or its critical parts) in a liquid and solidifying the liquid by cooling. After the launch shock and/or after the payload has landed, the solid is heated up and evaporated.

  12. Autonomous Bio-Optical Instruments

    Science.gov (United States)

    2000-09-30

    Autonomous Bio -Optical Instruments Russ E. Davis Scripps Institution of Oceanography La Jolla CA 92093-0230 phone: (858) 534-4415 fax: (858) 534... Bio -Optical Instruments 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK

  13. Instruments in science and technology

    NARCIS (Netherlands)

    Boon, Mieke; Olsen, Jan Kyrre Berg; Pedersen, Stig Andur; Hendricks, Vincent F.

    2009-01-01

    Modern science and technology are interwoven into a complex that is sometimes called 'techno-science': the progress of science is dependent on the sophistication of instrumentation, whereas the progress of ‘high-tech’ instruments and apparatus is dependent on scientific research. Yet, how scientific

  14. A Database Management Assessment Instrument

    Science.gov (United States)

    Landry, Jeffrey P.; Pardue, J. Harold; Daigle, Roy; Longenecker, Herbert E., Jr.

    2013-01-01

    This paper describes an instrument designed for assessing learning outcomes in data management. In addition to assessment of student learning and ABET outcomes, we have also found the instrument to be effective for determining database placement of incoming information systems (IS) graduate students. Each of these three uses is discussed in this…

  15. Experimenting with String Musical Instruments

    Science.gov (United States)

    LoPresto, Michael C.

    2012-01-01

    What follows are several investigations involving string musical instruments developed for and used in a "Science of Sound & Light" course. The experiments make use of a guitar, orchestral string instruments and data collection and graphing software. They are designed to provide students with concrete examples of how mathematical formulae, when…

  16. Kodaly Strategies for Instrumental Teachers.

    Science.gov (United States)

    Howard, Priscella M.

    1996-01-01

    Advocates using the singing voice and the study of folk music in instrumental instruction. Recommends instrumental teachers confer with voice teachers to coordinate ideas and terminology. Includes several excerpts of scores and musical exercises, as well as a list of selected resources. (MJP)

  17. Method for Determining Language Objectives and Criteria. Volume II. Methodological Tools: Computer Analysis, Data Collection Instruments.

    Science.gov (United States)

    1979-05-25

    This volume presents (1) Methods for computer and hand analysis of numerical language performance data (includes examples) (2) samples of interview, observation, and survey instruments used in collecting language data. (Author)

  18. Current and Nascent SETI Instruments

    CERN Document Server

    Siemion, Andrew P V; Chen, Henry; Cordes, Jim; Filiba, Terry; Foster, Griffin; Fries, Adam; Howard, Andrew; von Korff, Josh; Korpela, Eric; Lebofsky, Matt; McMahon, Peter L; Parsons, Aaron; Spitler, Laura; Wagner, Mark; Werthimer, Dan

    2011-01-01

    Here we describe our ongoing efforts to develop high-performance and sensitive instrumentation for use in the search for extra-terrestrial intelligence (SETI). These efforts include our recently deployed Search for Extraterrestrial Emissions from Nearby Developed Intelligent Populations Spectrometer (SERENDIP V.v) and two instruments currently under development; the Heterogeneous Radio SETI Spectrometer (HRSS) for SETI observations in the radio spectrum and the Optical SETI Fast Photometer (OSFP) for SETI observations in the optical band. We will discuss the basic SERENDIP V.v instrument design and initial analysis methodology, along with instrument architectures and observation strategies for OSFP and HRSS. In addition, we will demonstrate how these instruments may be built using low-cost, modular components and programmed and operated by students using common languages, e.g. ANSI C.

  19. Instrument Remote Control Application Framework

    Science.gov (United States)

    Ames, Troy; Hostetter, Carl F.

    2006-01-01

    The Instrument Remote Control (IRC) architecture is a flexible, platform-independent application framework that is well suited for the control and monitoring of remote devices and sensors. IRC enables significant savings in development costs by utilizing extensible Markup Language (XML) descriptions to configure the framework for a specific application. The Instrument Markup Language (IML) is used to describe the commands used by an instrument, the data streams produced, the rules for formatting commands and parsing the data, and the method of communication. Often no custom code is needed to communicate with a new instrument or device. An IRC instance can advertise and publish a description about a device or subscribe to another device's description on a network. This simple capability of dynamically publishing and subscribing to interfaces enables a very flexible, self-adapting architecture for monitoring and control of complex instruments in diverse environments.

  20. Instrumental variables and Mendelian randomization with invalid instruments

    Science.gov (United States)

    Kang, Hyunseung

    Instrumental variables (IV) methods have been widely used to determine the causal effect of a treatment, exposure, policy, or an intervention on an outcome of interest. The IV method relies on having a valid instrument, a variable that is (A1) associated with the exposure, (A2) has no direct effect on the outcome, and (A3) is unrelated to the unmeasured confounders associated with the exposure and the outcome. However, in practice, finding a valid instrument, especially those that satisfy (A2) and (A3), can be challenging. For example, in Mendelian randomization studies where genetic markers are used as instruments, complete knowledge about instruments' validity is equivalent to complete knowledge about the involved genes' functions. The dissertation explores the theory, methods, and application of IV methods when invalid instruments are present. First, when we have multiple candidate instruments, we establish a theoretical bound whereby causal effects are only identified as long as less than 50% of instruments are invalid, without knowing which of the instruments are invalid. We also propose a fast penalized method, called sisVIVE, to estimate the causal effect. We find that sisVIVE outperforms traditional IV methods when invalid instruments are present both in simulation studies as well as in real data analysis. Second, we propose a robust confidence interval under the multiple invalid IV setting. This work is an extension of our work on sisVIVE. However, unlike sisVIVE which is robust to violations of (A2) and (A3), our confidence interval procedure provides honest coverage even if all three assumptions, (A1)-(A3), are violated. Third, we study the single IV setting where the one IV we have may actually be invalid. We propose a nonparametric IV estimation method based on full matching, a technique popular in causal inference for observational data, that leverages observed covariates to make the instrument more valid. We propose an estimator along with