WorldWideScience

Sample records for survey facility arsf

  1. Properties and etching rates of negative ions in inductively coupled plasmas and dc discharges produced in Ar/SF6

    International Nuclear Information System (INIS)

    Draghici, M.; Stamate, E.

    2010-01-01

    Negative ion production is investigated in a chamber with transversal magnetic filter operated in dc or inductively coupled plasma (ICP) modes in Ar/SF 6 gas mixtures. Plasma parameters are evaluated by mass spectrometry and Langmuir probe for different discharge conditions. The density ratio of negative ion to electron exceeded 300 in dc mode while it was below 100 in the ICP mode. The possibility to apply a large positive bias to an electrode without affecting the plasma potential and the transition from a negative sheath to anodic glow are also investigated. The etching rates by positive and negative ions are evaluated on silicon substrate for different Ar/SF 6 gas ratios. The etching rate by negative ions was with less than 5% smaller than that by positive ions.

  2. Properties and etching rates of negative ions in inductively coupled plasmas and dc discharges produced in Ar/SF6

    DEFF Research Database (Denmark)

    Draghici, Mihai; Stamate, Eugen

    2010-01-01

    of negative ion to electron exceeded 300 in dc mode while it was below 100 in the ICP mode. The possibility to apply a large positive bias to an electrode without affecting the plasma potential and the transition from a negative sheath to anodic glow are also investigated. The etching rates by positive...... and negative ions are evaluated on silicon substrate for different Ar/SF6 gas ratios. The etching rate by negative ions was with less than 5% smaller than that by positive ions.......Negative ion production is investigated in a chamber with transversal magnetic filter operated in dc or inductively coupled plasma (ICP) modes in Ar/SF6 gas mixtures. Plasma parameters are evaluated by mass spectrometry and Langmuir probe for different discharge conditions. The density ratio...

  3. Lesotho - Health Facility Survey

    Data.gov (United States)

    Millennium Challenge Corporation — The main objective of the 2011 Health Facility Survey (HFS) was to establish a baseline for informing the Health Project performance indicators on health facilities,...

  4. Facilities Performance Indicators Report, 2004-05. Facilities Core Data Survey

    Science.gov (United States)

    Glazner, Steve, Ed.

    2006-01-01

    The purpose of "Facilities Performance Indicators" is to provide a representative set of statistics about facilities in educational institutions. The second iteration of the web-based Facilities Core Data Survey was posted and available to facilities professionals at more than 3,000 institutions in the Fall of 2005. The website offered a printed…

  5. Environmental Survey preliminary report, Pantex Facility, Amarillo, Texas

    International Nuclear Information System (INIS)

    1987-09-01

    This report presents the preliminary findings from the first phase of the Environmental Survey of the United States Department of Energy (DOE) Pantex Facility, conducted November 3 through 14, 1986.The Survey is being conducted by an interdisciplinary team of environmental specialist, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. Individual team components are outside experts being supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with the Pantex Facility. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. The on-site phase of the Survey involves the review of existing site environmental data, observations of the operations carried on at the Pantex Facility, and interviews with site personnel. The Survey team developed a Sampling and Analysis Plan to assist in further assessing certain of the environmental problems identified during its on-site activities. The Sampling and Analysis Plan will be executed by the Oak Ridge National Laboratory. When completed, the results will be incorporated into the Pantex Facility Environmental Survey Interim Report. The Interim Report will reflect the final determinations of the Survey for the Pantex Facility. 65 refs., 44 figs., 27 tabs

  6. Environmental Survey preliminary report, Pantex Facility, Amarillo, Texas

    Energy Technology Data Exchange (ETDEWEB)

    1987-09-01

    This report presents the preliminary findings from the first phase of the Environmental Survey of the United States Department of Energy (DOE) Pantex Facility, conducted November 3 through 14, 1986.The Survey is being conducted by an interdisciplinary team of environmental specialist, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. Individual team components are outside experts being supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with the Pantex Facility. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. The on-site phase of the Survey involves the review of existing site environmental data, observations of the operations carried on at the Pantex Facility, and interviews with site personnel. The Survey team developed a Sampling and Analysis Plan to assist in further assessing certain of the environmental problems identified during its on-site activities. The Sampling and Analysis Plan will be executed by the Oak Ridge National Laboratory. When completed, the results will be incorporated into the Pantex Facility Environmental Survey Interim Report. The Interim Report will reflect the final determinations of the Survey for the Pantex Facility. 65 refs., 44 figs., 27 tabs.

  7. 20 CFR 638.307 - Facility surveys.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Facility surveys. 638.307 Section 638.307 Employees' Benefits EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF LABOR JOB CORPS PROGRAM UNDER TITLE IV-B OF THE JOB TRAINING PARTNERSHIP ACT Funding, Site Selection, and Facilities Management § 638...

  8. Survey of current trends in DNA synthesis core facilities.

    Science.gov (United States)

    Hager, K M; Fox, J W; Gunthorpe, M; Lilley, K S; Yeung, A

    1999-12-01

    The Nucleic Acids Research Group of the Association of Biomolecular Resource Facilities (ABRF) last surveyed DNA synthesis core facilities in April 1995. Because of the introduction of new technologies and dramatic changes in the market, we sought to update survey information and to determine how academic facilities responded to the challenge presented by commercial counterparts. The online survey was opened in January 1999 by notifying members and subscribers to the ABRF electronic discussion group. The survey consisted of five parts: general facility information, oligonucleotide production profile, oligonucleotide charges, synthesis protocols, and trends in DNA synthesis (including individual comments). All submitted data were anonymously coded. Respondents from DNA synthesis facilities were primarily from the academic category and were established between 1984 and 1991. Typically, a facility provides additional services such as DNA sequencing and has upgraded to electronic ordering. There is stability in staffing profiles for these facilities in that the total number of employees is relatively unchanged, the tenure for staff averages 5.9 years, and experience is extensive. On average, academic facilities annually produce approximately 1/16 the number of oligonucleotides produced by the average commercial facilities, but all facilities report an increase in demand. Charges for standard oligonucleotides from academic facilities are relatively higher than from commercial companies; however, the opposite is true for modified phosphoramidites. Subsidized facilities charge less than nonsubsidized facilities. Synthesis protocols and reagents are standard across the categories. Most facilities offer typical modifications such as biotinylation. Despite the competition by large commercial facilities that have reduced costs dramatically, academic facilities remain a stable entity. Academic facilities enhance the quality of service by focusing on nonstandard

  9. University multi-user facility survey-2010.

    Science.gov (United States)

    Riley, Melissa B

    2011-12-01

    Multi-user facilities serve as a resource for many universities. In 2010, a survey was conducted investigating possible changes and successful characteristics of multi-user facilities, as well as identifying problems in facilities. Over 300 surveys were e-mailed to persons identified from university websites as being involved with multi-user facilities. Complete responses were received from 36 facilities with an average of 20 years of operation. Facilities were associated with specific departments (22%), colleges (22%), and university research centers (8.3%) or were not affiliated with any department or college within the university (47%). The five most important factors to succeed as a multi-user facility were: 1) maintaining an experienced, professional staff in an open atmosphere; 2) university-level support providing partial funding; 3) broad client base; 4) instrument training programs; and 5) an effective leader and engaged strategic advisory group. The most significant problems were: 1) inadequate university financial support and commitment; 2) problems recovering full service costs from university subsidies and user fees; 3) availability of funds to repair and upgrade equipment; 4) inability to retain highly qualified staff; and 5) unqualified users dirtying/damaging equipment. Further information related to these issues and to fee structure was solicited. Overall, there appeared to be a decline in university support for facilities and more emphasis on securing income by serving clients outside of the institution and by obtaining grants from entities outside of the university.

  10. A security/safety survey of long term care facilities.

    Science.gov (United States)

    Acorn, Jonathan R

    2010-01-01

    What are the major security/safety problems of long term care facilities? What steps are being taken by some facilities to mitigate such problems? Answers to these questions can be found in a survey of IAHSS members involved in long term care security conducted for the IAHSS Long Term Care Security Task Force. The survey, the author points out, focuses primarily on long term care facilities operated by hospitals and health systems. However, he believes, it does accurately reflect the security problems most long term facilities face, and presents valuable information on security systems and practices which should be also considered by independent and chain operated facilities.

  11. Survey of EPA facilities for solar thermal energy applications

    Science.gov (United States)

    Nelson, E. V.; Overly, P. T.; Bell, D. M.

    1980-01-01

    A study was done to assess the feasibility of applying solar thermal energy systems to EPA facilities. A survey was conducted to determine those EPA facilities where solar energy could best be used. These systems were optimized for each specific application and the system/facility combinations were ranked on the basis of greatest cost effectiveness.

  12. An aerial radiological survey of the RMI facility and surrounding area, Ashtabula, Ohio: Date of survey, September 1985

    International Nuclear Information System (INIS)

    1986-11-01

    An aerial radiological survey was conducted over a 75-square-kilometer (30-square-mile) area surrounding the RMI facility in Ashtabula, Ohio, during the period between September 4 and 13, 1985. The survey was conducted at an altitude of 46 meters (150 ft). A second, more detailed survey was also performed over the RMI facility. This survey was conducted at an altitude of 30 meters (100 ft) and covered an area of about 2.6 square kilometers (1 sq mi) centered over the facility. Over most of the survey area, exposure rates varied from about 8 to 11 microentgens per hour (μR/h). Several areas of increased radioactivity were observed in addition to increased radioactivity over the RMI facility (exposure rates of up to 44 μR/h were detected). The increased radioactivity over the RMI facility was due to uranium; however, no evidence of uranium was found off site. A second site exhibiting increased radioactivity was located near a railroad siding. The anomalous radiation there was due primarily to elevated concentrations of radium. Ground samples from this location were found to contain 130,000 picocuries per gram (pCi/g) of radium-226. Two other regions of anomalous radiation were found on the shore of Lake Erie, near Pinney Dock. One of these sites contained elevated concentrations of potassium-40 (K-40). The spectrum from the second site indicated the source to be thorium. A fifth site was a facility located a few hundred meters east of the RMI plant. The spectrum from this site also indicated an increased amount of thorium. Finally, a sixth source was located in the eastern portion of the survey area. The spectrum from this site was found to be high in cesium-137 (Cs-137). 7 refs., 14 figs., 2 tabs

  13. Spent Fuel Handling and Packaging Program: a survey of hot cell facilities

    International Nuclear Information System (INIS)

    Menon, M.N.

    1978-07-01

    Hot cell facilities in the United States were surveyed to determine their capabilities for conducting integral fuel assembly and individual fuel rod examinations that are required in support of the Spent Fuel Handling and Packaging Program. The ability to receive, handle, disassemble and reconstitute full-length light water reactor spent fuel assemblies, and the ability to conduct nondestructive and destructive examinations on full-length fuel rods were of particular interest. Three DOE-supported facilities and three commercial facilities were included in the survey. This report provides a summary of the findings

  14. Passive neutron survey of the 233-S Plutonium Concentration Facility

    International Nuclear Information System (INIS)

    1996-08-01

    A passive neutron survey was performed at the 233-S Plutonium Concentration Facility (located at the Hanford Site in Richland, Washington) during late 1994 and early 1995. Four areas were surveyed: an abandoned filter box and pipe trench, column laydown trench, load-out hood, and process hood. The primary purpose of the survey was to identify locations that had plutonium to help direct decontamination and decommissioning activities. A secondary purpose of the survey was to determine the quantity of material when its presence was identified

  15. Survey on evacuation facilities in case of nuclear emergency in Shimane prefecture (Contract research)

    International Nuclear Information System (INIS)

    Takahara, Shogo; Watanabe, Masatoshi; Oguri, Tomomi; Kimura, Masanori; Hirouchi, Jun; Munakata, Masahiro; Homma, Toshimitsu

    2017-02-01

    To contribute evaluations of dose reduction effect due to evacuation facilities in case of nuclear emergency, we surveyed on structural and material data on 22 facilities (290 rooms) which are listed in local disaster management plan in Matsue city. These facilities can be divided into three categories in terms of structure, scale and intended purpose of them: educational facilities (12 facilities, 235 rooms (include gymnastic hall)), communal facilities (7 facilities, 42 rooms) and gymnastic hall (3 facilities, 13 rooms). Height and floor-area of rooms, as well as window-area were collected as the structural data. We also collected information on constructional materials (i.e. roof, ceiling, inner wall, outer wall, window, floor), and density of those. In addition, mass-thicknesses of the constructional materials were evaluated based on our surveys, and compared to the previous studies which were made in Japan, U.S., and European countries. Consequently, it was found that there is no significant difference of mass-thickness of constructional materials between the results of our surveys and the previous studies. However, for gymnastic hall, since thin metal plates are used for roofs, we can point out that the mass-thickness of roofs are much lower than those for other concrete facilities and clay tile roofing wooden houses. (author)

  16. Aerial radiological survey of the US Department of Energy's Mound Facility, Miamisburg, Ohio

    International Nuclear Information System (INIS)

    1978-03-01

    An aerial radiological survey to measure terrestrial gamma radiation was carried out by helicopter over an area centered on Mound Facility, a 180 acre area adjacent to the southern edge of the city of Miamisburg, Ohio. This survey was part of an effort to document background radiation levels around nuclear processing and handling facilities owned or contracted by the United States Department of Energy (DOE). Survey activities were conducted and performed by EG and G for the DOE. Wright-Patterson Air Force Base served as the survey base of operations. During the survey, gamma ray data were collected over a 12.3 km 2 area by flying an east-west grid of lines spaced 61 m apart, flying slowly over several selected areas, and hovering over several spots of interest. The processed data indicated that the on-site radioactivity was primarily due to radionuclides currently being handled or processed at the Facility, and that lesser activity could be attributed to previously handled or processed nuclear materials. Off-site data showed the radioactivity to be that only due to naturally occurring radionuclides

  17. Development, application, and validation of a survey for infectious disease control practices at equine boarding facilities.

    Science.gov (United States)

    Kirby, Alanna T; Traub-Dargatz, Josie L; Hill, Ashley E; Kogan, Lori R; Morley, Paul S; Heird, James C

    2010-11-15

    To develop a questionnaire for self-assessment of biosecurity practices at equine boarding facilities and to evaluate infectious disease control practices in these facilities in Colorado. Cross-sectional study. 64 equine boarding facilities in Colorado. Survey questions were rated according to importance for prevention and containment of equine infectious diseases. Point values (range, 0 to 20) were assigned for possible responses, with greater values given for optimal infection control methods. Questionnaires were mailed to equine boarding facilities in Colorado advertised on the World Wide Web. Survey responses were compared with assessments made by a member of the research team during visits to 30 randomly selected facilities. Agreement among results was analyzed via a kappa test and rated as poor, fair, moderate, substantial, or nearly perfect. Survey responses were received for 64 of 163 (39%) equine boarding facilities. Scores ranged from 106 to 402 points (maximum possible score, 418). Most facilities received better scores for movement and housing of equids than for other sections of the survey. Respondents at 24 of 48 (50%) facilities that routinely received new equids reported isolation of new arrivals. Agreement between self-assessment by survey respondents and evaluation by a member of the research team was determined to be fair to substantial. Most equine boarding facilities have opportunities to improve measures for prevention or containment of contagious diseases (eg, isolation of newly arrived equids and use of written health management protocols). Most self-assessments of infection control practices were accurate.

  18. Business administration of PET facilities. A nationwide survey for prices of PET screening and a cost analysis of three facilities

    International Nuclear Information System (INIS)

    Mitsutake, Naohiro; Fujii, Ryo; Oku, Shinya; Furui, Yuji; Yasunaga, Hideo

    2007-01-01

    The purpose of this study is to analyze the business administration of positron emission tomography (PET) facilities based on the survey of the price of PET cancer screening and cost analysis of PET examination. The questionnaire survey of the price of PET cancer screening was implemented for all PET facilities in Japan. Cost data of PET examination, including fixed costs and variable costs, were obtained from three different medical institutions. The marked price of the PET cancer screening was yen111,499 in average, and the most popular range of prices was between yen80,000 and yen90,000. Costs of PET per examination were accounted for yen110,675, yen79,158 and yen111,644 in facility A, B and C, respectively. The results suggested that facilities with two or more PET/CT per a cyclotron could only secure profits. In Japan, the boom in PET facility construction could not continue in accordance with increasing number of PET facilities. It would become more essential to analyze the appropriate distribution of PET facilities and the adequate amount of PET procedures from the perspective of efficient utilization of the PET equipments and supply of PET-related healthcare. (author)

  19. Modified electrical survey for effective leakage detection at concrete hydraulic facilities

    Science.gov (United States)

    Lee, Bomi; Oh, Seokhoon

    2018-02-01

    Three original electrode arrays for the effective leakage detection of concrete hydraulic facilities through electrical resistivity surveys are proposed: 'cross-potential', 'direct-potential' and modified tomography-like arrays. The main differences with respect to the commonly used arrays are that the current line-sources are separated from potential pole lines and floated upon the water. The potential pole lines are located directly next to the facility in order to obtain intuitive data and useful interpretations of the internal conditions of the hydraulic facility. This modified configuration of the array clearly displays the horizontal variation of the electrical field around the damaged zones of the concrete hydraulic facility, and any anomalous regions that might be found between potential poles placed across the facilities. In order to facilitate the interpretation of these modified electrical surveys, a new and creative way of presenting the measurements is also proposed and an inversion approach is provided for the modified tomography-like array. A numerical modeling and two field tests were performed to verify these new arrays and interpretation methods. The cross and direct potential array implied an ability to detect small variations of the potential field near the measurement poles. The proposed array showed the overall potential distribution across the hydraulic facility which may be used to assist in the search of trouble zones within the structure, in combination with the traditional electrical resistivity array.

  20. Survey of facilities for appropriate training in blood transfusion

    African Journals Online (AJOL)

    2018-06-01

    Jun 1, 2018 ... Objective. To survey training facilities for blood transfusion in Anglophone West. Africa for ... to provide workforce for blood transfusion establishments. However, ... A standard blood service is a multi-disciplinary organization in which .... and good manufacturing practices in the blood transfusion laboratory.

  1. Annual evaluation of routine radiological survey/monitoring frequencies for the High Ranking Facilities Deactivating Project at Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1998-12-01

    The Bethel Valley Watershed at the Oak Ridge National Laboratory (ORNL) has several Environmental Management (EM) facilities that are designated for deactivation and subsequent decontamination and decommissioning (D and D). The Surplus Facilities Program at ORNL provides surveillance and maintenance support for these facilities as deactivation objectives are completed to reduce the risks associated with radioactive material inventories, etc. The Bechtel Jacobs Company LLC Radiological Control (RADCON) Program has established requirements for radiological monitoring and surveying radiological conditions in these facilities. These requirements include an annual evaluation of routine radiation survey and monitoring frequencies. Radiological survey/monitoring frequencies were evaluated for two High Ranking Facilities Deactivation Project facilities, the Bulk Shielding Facility and Tower Shielding Facility. Considerable progress has been made toward accomplishing deactivation objectives, thus the routine radiological survey/monitoring frequencies are being reduced for 1999. This report identifies the survey/monitoring frequency adjustments and provides justification that the applicable RADCON Program requirements are also satisfied

  2. Survey of secular change for the buildings of nuclear fuel facility in JNC Tokai Works

    International Nuclear Information System (INIS)

    Uryu, Mitsuru; Kyue, Tadashi; Satoko, Hiroyuki; Yamazaki, Toshihiko

    2002-06-01

    Some nuclear facilities of JNC such as Tokai Reprocessing Plant or Tokai Plutonium Fuel plant have been operating over 20 years since their completion. These facilities' buildings are constructed near the seaside, so we are that, we are surveying the secular change, estimating the tendency and counterplan to operate the facilities stably. In this paper, we report the abstract of the result of the survey, and the maintenance stage of the diagnostic techniques etc. (author)

  3. Survey of technology for decommissioning of nuclear fuel cycle facilities. 8. Remote handling and cutting techniques

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Ryuichiro; Ishijima, Noboru [Japan Nuclear Cycle Development Inst., Oarai, Ibaraki (Japan). Oarai Engineering Center

    1999-03-01

    In nuclear fuel cycle facility decommissioning and refurbishment, the remote handling techniques such as dismantling, waste handling and decontamination are needed to reduce personnel radiation exposure. The survey research for the status of R and D activities on remote handling tools suitable for nuclear facilities in the world and domestic existing commercial cutting tools applicable to decommissioning of the facilities was conducted. In addition, the drive mechanism, sensing element and control system applicable to the remote handling devices were also surveyed. This report presents brief surveyed summaries. (H. Itami)

  4. Aerial radiological survey of the area surrounding the UNC Recovery Systems Facility, Wood River Junction, Rhode Island. Date of survey: August 1979

    International Nuclear Information System (INIS)

    1979-12-01

    An aerial radiological survey to measure terrestrial gamma radiation was carried out over the UNC Recovery Systems facility located near Wood River Junction, Rhode Island. At the time of the survey (August 1979) materials were being processed at the facility. Gamma ray data were collected over a 3.63 km 2 area centered on the facility by flying north-south lines spaced 60 m apart. Processed data indicated that detected radioisotopes and their associated gamma ray exposure rates were consistent with those expected from normal background emitters, except at certain locations described in this report. Average exposure rates 1 m above the ground, as calculated from the aerial data, are presented in the form of an isopleth map. No ground sample data were taken at the time of the aerial survey

  5. Questionnaire survey report on measurement of radioactivity in working environment of radioisotopes facility

    International Nuclear Information System (INIS)

    Kawano, Takao; Nomura, Kiyoshi

    2008-01-01

    To look over the current measurement of radioactivity concentration in working environment of many radioisotopes facilities, a questionnaire survey was carried out under the auspices of the Planning Committee of the Japan Society of Radiation Safety Management. 64 responses were obtained in 128 radiation facilities, which the questionnaires were sent to. The main results were obtained by aggregate analysis of the answers for questionnaires as the followings. Major nuclides subject to measurement were 3 H, 14 C, 32 P and 125 I Sampling of radioisotopes in air was mainly performed using collectors like dust samplers and HC-collectors. Liquid scintillation counters and gamma counters were used to measure β and γ radioactivity contained in airborne particles or gas samples. Contamination by radioactivity was not detected in 55% facilities surveyed, but in 40% facilities at the same level as or at lower levels than a hundredth part of the regulated concentration limit of each nuclide. Almost all facilities is found to consider that the measurement of radioactivity concentration in working environments is not always necessary. (author)

  6. A survey of ecological risk assessment at DOE facilities

    International Nuclear Information System (INIS)

    Barnthouse, L.W.; Bascietto, J.; Joseph, T.; Bilyard, G.

    1992-01-01

    The US Department of Energy (DOE) Risk-Based Standards Working Group is studying standard-setting and remedial action based on realistic estimates of human health and ecological risks. Federal and state regulations require DOE to assess ecological risks due to present and past operation of DOE facilities and ecological damage caused by remedial actions. Unfortunately, little technical guidance has been provided by regulatory agencies about how these assessments should be performed or what constitutes an adequate assessment. Active ecological research, environmental characterization, and ecological risk assessment programs are already underway at many locations. Some of these programs were established more than 30 years ago. Because of the strength of its existing programs and the depth of expertise available within the DOE complex, the agency is in a position to lead in developing ecological risk assessment procedures that are fully consistent with the general principles defined by EPA and that will ensure environmentally sound and cost-effective restoration of its sites. As a prelude to guidance development, the working group conducted a survey of ecological risk assessment activities at a subset of major DOE facilities. The survey was intended to (1) identify approaches now being used in ecological risk assessments performed by DOE staff and contractors at each site, (2) record successes and failures of these approaches, (3) identify new technical developments with potential for general application to many DOE facilities, and (4) identify major data needs, data resources, and methodological deficiencies

  7. The problem of bias when nursing facility staff administer customer satisfaction surveys.

    Science.gov (United States)

    Hodlewsky, R Tamara; Decker, Frederic H

    2002-10-01

    Customer satisfaction instruments are being used with increasing frequency to assess and monitor residents' assessments of quality of care in nursing facilities. There is no standard protocol, however, for how or by whom the instruments should be administered when anonymous, written responses are not feasible. Researchers often use outside interviewers to assess satisfaction, but cost considerations may limit the extent to which facilities are able to hire outside interviewers on a regular basis. This study was designed to investigate the existence and extent of any bias caused by staff administering customer satisfaction surveys. Customer satisfaction data were collected in 1998 from 265 residents in 21 nursing facilities in North Dakota. Half the residents in each facility were interviewed by staff members and the other half by outside consultants; scores were compared by interviewer type. In addition to a tabulation of raw scores, ordinary least-squares analysis with facility fixed effects was used to control for resident characteristics and unmeasured facility-level factors that could influence scores. Significant positive bias was found when staff members interviewed residents. The bias was not limited to questions directly affecting staff responsibilities but applied across all types of issues. The bias was robust under varying constructions of satisfaction and dissatisfaction. A uniform method of survey administration appears to be important if satisfaction data are to be used to compare facilities. Bias is an important factor that should be considered and weighed against the costs of obtaining outside interviewers when assessing customer satisfaction among long term care residents.

  8. Preoperational Environmental Survey for the Spent Nuclear Fuel (SNF) Project Facilities

    International Nuclear Information System (INIS)

    MITCHELL, R.M.

    2000-01-01

    This document represents the report for environmental sampling of soil, vegetation, litter, cryptograms, and small mammals at the Spent Nuclear Fuel Project facilities located in 100 K and 200 East Areas in support of the preoperational environmental survey

  9. Preoperational Environmental Survey for the Spent Nuclear Fuel (SNF) Project Facilities

    Energy Technology Data Exchange (ETDEWEB)

    MITCHELL, R.M.

    2000-10-12

    This document represents the report for environmental sampling of soil, vegetation, litter, cryptograms, and small mammals at the Spent Nuclear Fuel Project facilities located in 100 K and 200 East Areas in support of the preoperational environmental survey.

  10. Preoperational Environmental Survey for the Spent Nuclear Fuel (SNF) Project Facilities

    Energy Technology Data Exchange (ETDEWEB)

    MITCHELL, R.M.

    2000-09-28

    This document represents the report for environmental sampling of soil, vegetation, litter, cryptograms, and small mammals at the Spent Nuclear Fuel Project facilities located in 100 K and 200 East Areas in support of the preoperational environmental survey.

  11. An aerial radiological survey of the Savannah River Site TNX facility and surrounding area, Aiken, South Carolina

    International Nuclear Information System (INIS)

    1991-06-01

    An aerial radiological survey was conducted over a 3.8-square-kilometer (1.5-square-mile) area, centered on the Savannah River Site (SRS) TNX facility. The survey was flown on July 25, 1986, prior to the Steel Creek Corridor survey. Radiological measurements were used to determine the extent of man-made radionuclides in the TNX area. This survey area had been covered during previous site surveys of the Savannah River Floodplain. Higher than typical levels of thorium-232 daughters were detected in the survey area just west of the TNX facility. The natural terrestrial radiation levels were consistent with those measured during prior surveys of this and other SRS areas. 5 refs., 12 figs., 2 tabs

  12. Aerial radiological survey of the area surrounding the UNC Recovery Systems Facility, Wood River Junction, Rhode Island

    International Nuclear Information System (INIS)

    Bluitt, C.M.

    1981-05-01

    An aerial radiological survey to measure terrestrial gamma radiation was carried out over the United Nuclear Corporation (UNC) Recovery Systems Facility located near Wood River Junction, Rhode Island. At the time of the survey (August 1979) materials were being processed at the facility. Gamma ray data were collected over a 3.28 km 2 area centered on the facility by flying north-south lines spaced 60 m apart. Processed data indicated that detected radioisotopes and their associated gamma ray exposure rates were consistent with those expected from normal background emitters, except directly over the UNC Facility. Average exposure rates 1 m above the ground, as calculated from the aerial data, are presented in the form of an isopleth map. No ground sample data were taken at the time of the aerial survey

  13. Sandia National Laboratories, California proposed CREATE facility environmental baseline survey.

    Energy Technology Data Exchange (ETDEWEB)

    Catechis, Christopher Spyros

    2013-10-01

    Sandia National Laboratories, Environmental Programs completed an environmental baseline survey (EBS) of 12.6 acres located at Sandia National Laboratories/California (SNL/CA) in support of the proposed Collaboration in Research and Engineering for Advanced Technology and Education (CREATE) Facility. The survey area is comprised of several parcels of land within SNL/CA, County of Alameda, California. The survey area is located within T 3S, R 2E, Section 13. The purpose of this EBS is to document the nature, magnitude, and extent of any environmental contamination of the property; identify potential environmental contamination liabilities associated with the property; develop sufficient information to assess the health and safety risks; and ensure adequate protection for human health and the environment related to a specific property.

  14. Does health facility service environment matter for the receipt of essential newborn care? Linking health facility and household survey data in Malawi.

    Science.gov (United States)

    Carvajal-Aguirre, Liliana; Mehra, Vrinda; Amouzou, Agbessi; Khan, Shane M; Vaz, Lara; Guenther, Tanya; Kalino, Maggie; Zaka, Nabila

    2017-12-01

    Health facility service environment is an important factor for newborns survival and well-being in general and in particular in high mortality settings such as Malawi where despite high coverage of essential interventions, neonatal mortality remains high. The aim of this study is to assess whether the quality of the health service environment at birth is associated with quality of care received by the newborn. We used data from the Malawi Millennium Development Goals Endline household survey conducted as part of MICS survey program and Service Provision Assessment Survey carried out in 2014. The analysis is based on 6218 facility births that occurred during the past 2 years. Descriptive statistics, bivariate and multivariate random effect models are used to assess the association of health facility service readiness score for normal deliveries and newborn care with newborns receiving appropriate newborn care, defined for this analysis as receiving 5 out of 6 recommended interventions during the first 2 days after birth. Newborns in districts with top facility service readiness score have 1.5 higher odds of receiving appropriate newborn care (adjusted odds ratio (aOR) = 1.52, 95% confidence interval CI = 1.19-1.95, P  = 0.001), as compared to newborns in districts with a lower facility score after adjusting for potential confounders. Newborns in the Northern region were two times more likely to receive 5 newborn care interventions as compared to newborns in the Southern region (aOR = 2.06, 95% CI = 1.50-2.83, P  < 0.001). Living in urban or rural areas did not have an impact on receiving appropriate newborn care. There is need to increase the level of service readiness across all facilities, so that all newborns irrespective of the health facility, district or region of delivery are able to receive all recommended essential interventions. Investments in health systems in Malawi should concentrate on increasing training and availability of

  15. Standard protocol for demographic and epidemiological survey to be carried out for nuclear facilities

    International Nuclear Information System (INIS)

    Joshi, M.L.; Datta, D.; Singh, Jitendra; Sardhi, I.V.; Verma, P.C.

    2007-11-01

    This document presents the standard procedures for conducting demographic and epidemiological studies for nuclear facilities. These studies are required to be carried out to prepare baseline data, the impact of the facility and the risk factors for the population residing in the vicinity of facility. This document includes the basic elements of these type surveys, their methodology and statistical analysis of the data collected during demographic and epidemiological surveillance. (author)

  16. Standard protocol for demographic and epidemiological survey to be carried out for nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, M L; Datta, D; Singh, Jitendra; Sardhi, I V; Verma, P C [Health Physics Division, Bhabha Atomic Research Centre, Mumbai (India)

    2007-11-15

    This document presents the standard procedures for conducting demographic and epidemiological studies for nuclear facilities. These studies are required to be carried out to prepare baseline data, the impact of the facility and the risk factors for the population residing in the vicinity of facility. This document includes the basic elements of these type surveys, their methodology and statistical analysis of the data collected during demographic and epidemiological surveillance. (author)

  17. Current status of collaborative relationships between dialysis facilities and dental facilities in Japan: results of a nationwide survey.

    Science.gov (United States)

    Yoshioka, Masami; Shirayama, Yasuhiko; Imoto, Issei; Hinode, Daisuke; Yanagisawa, Shizuko; Takeuchi, Yuko

    2015-02-12

    Recent studies have reported an association between periodontal disease and mortality among dialysis patients. Therefore, preventive dental care should be considered very important for this population. In Japan, no systematic education has been undertaken regarding the importance of preventive dental care for hemodialysis patients--even though these individuals tend to have oral and dental problems. The aim of this study was to investigate the current state of collaborative relationships between hemodialysis facilities and dental services in Japan and also to identify strategies to encourage preventive dental visits among hemodialysis outpatients. A nationwide questionnaire on the collaborative relationship between dialysis facilities and dental facilities was sent by mail to all medical facilities in Japan offering outpatient hemodialysis treatment. Responses were obtained from 1414 of 4014 facilities (35.2%). Among the 1414 facilities, 272 (19.2%) had a dental service department. Approximately 100,000 dialysis outpatients were receiving treatment at these participating facilities, which amounts to one-third of all dialysis patients in Japan. Of those patients, 82.9% received hemodialysis at medical facilities without dental departments. Only 87 of 454 small clinics without in-house dental departments (19.2%) had collaborative registered dental clinics. Medical facilities with registered dental clinics demonstrated a significantly more proactive attitude to routine collaboration on dental matters than facilities lacking such clinics. Our nationwide survey revealed that most dialysis facilities in Japan have neither an in-house dental department nor a collaborative relationship with a registered dental clinic. Registration of dental clinics appears to promote collaboration with dental facilities on a routine basis, which would be beneficial for oral health management in hemodialysis patients.

  18. Quality of newborn care: a health facility assessment in rural Ghana using survey, vignette and surveillance data

    NARCIS (Netherlands)

    Vesel, Linda; Manu, Alexander; Lohela, Terhi J.; Gabrysch, Sabine; Okyere, Eunice; ten Asbroek, Augustinus H. A.; Hill, Zelee; Agyemang, Charlotte Tawiah; Owusu-Agyei, Seth; Kirkwood, Betty R.

    2013-01-01

    To assess the structural capacity for, and quality of, immediate and essential newborn care (ENC) in health facilities in rural Ghana, and to link this with demand for facility deliveries and admissions. Health facility assessment survey and population-based surveillance data. Seven districts in

  19. Quality of malaria case management in Malawi: results from a nationally representative health facility survey.

    Science.gov (United States)

    Steinhardt, Laura C; Chinkhumba, Jobiba; Wolkon, Adam; Luka, Madalitso; Luhanga, Misheck; Sande, John; Oyugi, Jessica; Ali, Doreen; Mathanga, Don; Skarbinski, Jacek

    2014-01-01

    Malaria is endemic throughout Malawi, but little is known about quality of malaria case management at publicly-funded health facilities, which are the major source of care for febrile patients. In April-May 2011, we conducted a nationwide, geographically-stratified health facility survey to assess the quality of outpatient malaria diagnosis and treatment. We enrolled patients presenting for care and conducted exit interviews and re-examinations, including reference blood smears. Moreover, we assessed health worker readiness (e.g., training, supervision) and health facility capacity (e.g. availability of diagnostics and antimalarials) to provide malaria case management. All analyses accounted for clustering and unequal selection probabilities. We also used survey weights to produce estimates of national caseloads. At the 107 facilities surveyed, most of the 136 health workers interviewed (83%) had received training on malaria case management. However, only 24% of facilities had functional microscopy, 15% lacked a thermometer, and 19% did not have the first-line artemisinin-based combination therapy (ACT), artemether-lumefantrine, in stock. Of 2,019 participating patients, 34% had clinical malaria (measured fever or self-reported history of fever plus a positive reference blood smear). Only 67% (95% confidence interval (CI): 59%, 76%) of patients with malaria were correctly prescribed an ACT, primarily due to missed malaria diagnosis. Among patients without clinical malaria, 31% (95% CI: 24%, 39%) were prescribed an ACT. By our estimates, 1.5 million of the 4.4 million malaria patients seen in public facilities annually did not receive correct treatment, and 2.7 million patients without clinical malaria were inappropriately given an ACT. Malawi has a high burden of uncomplicated malaria but nearly one-third of all patients receive incorrect malaria treatment, including under- and over-treatment. To improve malaria case management, facilities must at minimum have

  20. Survey of European LWR fuel irradiation test facilities

    Energy Technology Data Exchange (ETDEWEB)

    Hardt, P von der [Commission of the European Communities, Joint Research Centre, Petten Establishment, Petten (Netherlands)

    1983-06-01

    The first European commercial nuclear power plants (1956) featured gas-cooled thermal reactors. Although there is now a general orientation towards light water cooled plants (with a slight preference for the PWR) a large fraction of the 1982 nuclear generating capacity is still invested in gas-cooled reactors. R and D also continues for the HTGR with its long-term development potential. This paper, however, is limited to a general survey of experimental programmes and facilities for light water reactor fuel testing in Western Europe, particularly inside the European Communities. As it turns out, over a dozen major installations are available, all connected to research reactors in government-funded R and D centres. Their equipment is briefly reviewed. Some 50% of the experimental programmes are carried out in large international collaboration, involving up to 20 organizations per project. Techniques and results are rapidly communicated through frequent meetings and conferences. It is anticipated that a part of the present research reactor-based work will gradually shift to power reactor pool side inspection facilities. (author)

  1. Survey of European LWR fuel irradiation test facilities

    International Nuclear Information System (INIS)

    Hardt, P. von der

    1983-01-01

    The first European commercial nuclear power plants (1956) featured gas-cooled thermal reactors. Although there is now a general orientation towards light water cooled plants (with a slight preference for the PWR) a large fraction of the 1982 nuclear generating capacity is still invested in gas-cooled reactors. R and D also continues for the HTGR with its long-term development potential. This paper, however, is limited to a general survey of experimental programmes and facilities for light water reactor fuel testing in Western Europe, particularly inside the European Communities. As it turns out, over a dozen major installations are available, all connected to research reactors in government-funded R and D centres. Their equipment is briefly reviewed. Some 50% of the experimental programmes are carried out in large international collaboration, involving up to 20 organizations per project. Techniques and results are rapidly communicated through frequent meetings and conferences. It is anticipated that a part of the present research reactor-based work will gradually shift to power reactor pool side inspection facilities. (author)

  2. A control system of a mini survey facility for photometric monitoring

    Science.gov (United States)

    Tsutsui, Hironori; Yanagisawa, Kenshi; Izumiura, Hideyuki; Shimizu, Yasuhiro; Hanaue, Takumi; Ita, Yoshifusa; Ichikawa, Takashi; Komiyama, Takahiro

    2016-08-01

    We have built a control system for a mini survey facility dedicated to photometric monitoring of nearby bright (Kdome and a small (30-mm aperture) wide-field (5 × 5 sq. deg. field of view) infrared (1.0-2.5 microns) camera on an equatorial fork mount, as well as power sources and other associated equipment. All the components other than the camera are controlled by microcomputerbased I/O boards that were developed in-house and are in many of the open-use instruments in our observatory. We present the specifications and configuration of the facility hardware, as well as the structure of its control software.

  3. The Green Dialysis Survey: Establishing a Baseline for Environmental Sustainability across Dialysis Facilities in Victoria, Australia.

    Science.gov (United States)

    Barraclough, Katherine A; Gleeson, Alice; Holt, Stephen G; Agar, John Wm

    2017-11-02

    The Green Dialysis Survey aimed to 1) establish a baseline for environmental sustainability (ES) across Victorian dialysis facilities, and 2) guide future initiatives to reduce the environmental impact of dialysis delivery. Nurse unit managers of all Victorian public dialysis facilities received an online link to the survey, which asked 107 questions relevant to the ES of dialysis services. Responses were received from 71/83 dialysis facilities in Victoria (86%), representing 628/660 dialysis chairs (95%). Low energy lighting was present in 13 facilities (18%), 18 (25%) recycled reverse osmosis water and 7 (10%) reported use of renewable energy. Fifty-six facilities (79%) performed comingled recycling but only 27 (38%) recycled polyvinyl chloride plastic. A minority educated staff in appropriate waste management (n=30;42%) or formally audited waste generation and segregation (n=19;27%). Forty-four (62%) provided secure bicycle parking but only 33 (46%) provided shower and changing facilities. There was limited use of tele- or video-conferencing to replace staff meetings (n=19;27%) or patient clinic visits (n=13;18%). A minority considered ES in procurement decisions (n=28;39%) and there was minimal preparedness to cope with climate change. Only 39 services (49%) confirmed an ES policy and few had ever formed a green group (n=14; 20%) or were currently undertaking a green project (n=8;11%). Only 15 facilities (21%) made formal efforts to raise awareness of ES. This survey provides a baseline for practices that potentially impact the environmental sustainability of dialysis units in Victoria, Australia. It also identifies achievable targets for attention. This article is protected by copyright. All rights reserved.

  4. Animal-assisted interventions: A national survey of health and safety policies in hospitals, eldercare facilities, and therapy animal organizations.

    Science.gov (United States)

    Linder, Deborah E; Siebens, Hannah C; Mueller, Megan K; Gibbs, Debra M; Freeman, Lisa M

    2017-08-01

    Animal-assisted intervention (AAI) programs are increasing in popularity, but it is unknown to what extent therapy animal organizations that provide AAI and the hospitals and eldercare facilities they work with implement effective animal health and safety policies to ensure safety of both animals and humans. Our study objective was to survey hospitals, eldercare facilities, and therapy animal organizations on their AAI policies and procedures. A survey of United States hospitals, eldercare facilities, and therapy animal organizations was administered to assess existing health and safety policies related to AAI programs. Forty-five eldercare facilities, 45 hospitals, and 27 therapy animal organizations were surveyed. Health and safety policies varied widely and potentially compromised human and animal safety. For example, 70% of therapy animal organizations potentially put patients at risk by allowing therapy animals eating raw meat diets to visit facilities. In general, hospitals had stricter requirements than eldercare facilities. This information suggests that there are gaps between the policies of facilities and therapy animal organizations compared with recent guidelines for animal visitation in hospitals. Facilities with AAI programs need to review their policies to address recent AAI guidelines to ensure the safety of animals and humans involved. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  5. Ecological survey for the siting of the Mixed and Low-Level Waste Treatment Facility and the Idaho Waste Processing Facility

    International Nuclear Information System (INIS)

    Hoskinson, R.L.

    1994-05-01

    This report summarizes the results of field ecological surveys conducted by the Center for Integrated Environmental Technologies (CIET) on the Idaho National Engineering Laboratory (INEL) at four candidate locations for the siting of the Mixed and Low-Level Waste Treatment Facility (MLLWTF) and the Idaho Waste Processing Facility (IWPF). The purpose of these surveys was to comply with all Federal laws and Executive Orders to identify and evaluate any potential environmental impacts because of the project. The boundaries of the candidate location were marked with blaze-orange lath survey marker stakes by the project management. Global Positioning System (GPS) measurements of the marker stakes were made, and input to the Arc/Info reg-sign geographic information system (GIS). Field surveys were conducted to assess any potential impact to any important species, important habitats, and to any environmental study areas. The GIS location data was overlayed onto the INEL vegetation map and an analysis of vegetation classes on the locations was done. Results of the field surveys indicate use of Candidate Location number-sign 1 by pygmy rabbits (Sylvilagus idahoensis) and expected use by them of Candidate Locations number-sign 3 and number-sign 9. Pygmy rabbits are categorized as a C2 species by the US Fish and Wildlife Service (USFWS). Two other C2 species, the ferruginous hawk (Buteo regalis) and the loggerhead shrike (Lanius ludovicianus) would also be expected to frequent the candidate locations. Candidate Location number-sign 5 at the north end of the INEL is in the winter range of a large number of pronghorn antelope (Antilocapra americana)

  6. Health facility service availability and readiness for intrapartum and immediate postpartum care in Malawi: A cross-sectional survey.

    Directory of Open Access Journals (Sweden)

    Naoko Kozuki

    Full Text Available This analysis seeks to identify strengths and gaps in the existing facility capacity for intrapartum and immediate postpartum fetal and neonatal care, using data collected as a part of Malawi's Helping Babies Breath program evaluation. From August to September 2012, the Maternal and Child Health Integrated Program (MCHIP conducted a cross-sectional survey in 84 Malawian health facilities to capture current health facility service availability and readiness and health worker capacity and practice pertaining to labor, delivery, and immediate postpartum care. The survey collected data on availability of equipment, supplies, and medications, and health worker knowledge and performance scores on intrapartum care simulation and actual management of real clients at a subset of facilities. We ran linear regression models to identify predictors of high simulation performance of routine delivery care and management of asphyxiated newborns across all facilities surveyed. Key supplies for infection prevention and thermal care of the newborn were found to be missing in many of the surveyed facilities. At the health center level, 75% had no clinician trained in basic emergency obstetric care or newborn care and 39% had no midwife trained in the same. We observed that there were no proportional increases in available transport and staff at a facility as catchment population increased. In simulations of management of newborns with breathing problems, health workers were able to complete a median of 10 out of 16 tasks for a full-term birth case scenario and 20 out of 30 tasks for a preterm birth case scenario. Health workers who had more years of experience appeared to perform worse. Our study provides a benchmark and highlights gaps for future evaluations and studies as Malawi continues to make strides in improving facility-based care. Further progress in reducing the burden of neonatal and fetal death in Malawi will be partly predicated on guaranteeing

  7. Health facility service availability and readiness for intrapartum and immediate postpartum care in Malawi: A cross-sectional survey.

    Science.gov (United States)

    Kozuki, Naoko; Oseni, Lolade; Mtimuni, Angella; Sethi, Reena; Rashidi, Tambudzai; Kachale, Fannie; Rawlins, Barbara; Gupta, Shivam

    2017-01-01

    This analysis seeks to identify strengths and gaps in the existing facility capacity for intrapartum and immediate postpartum fetal and neonatal care, using data collected as a part of Malawi's Helping Babies Breath program evaluation. From August to September 2012, the Maternal and Child Health Integrated Program (MCHIP) conducted a cross-sectional survey in 84 Malawian health facilities to capture current health facility service availability and readiness and health worker capacity and practice pertaining to labor, delivery, and immediate postpartum care. The survey collected data on availability of equipment, supplies, and medications, and health worker knowledge and performance scores on intrapartum care simulation and actual management of real clients at a subset of facilities. We ran linear regression models to identify predictors of high simulation performance of routine delivery care and management of asphyxiated newborns across all facilities surveyed. Key supplies for infection prevention and thermal care of the newborn were found to be missing in many of the surveyed facilities. At the health center level, 75% had no clinician trained in basic emergency obstetric care or newborn care and 39% had no midwife trained in the same. We observed that there were no proportional increases in available transport and staff at a facility as catchment population increased. In simulations of management of newborns with breathing problems, health workers were able to complete a median of 10 out of 16 tasks for a full-term birth case scenario and 20 out of 30 tasks for a preterm birth case scenario. Health workers who had more years of experience appeared to perform worse. Our study provides a benchmark and highlights gaps for future evaluations and studies as Malawi continues to make strides in improving facility-based care. Further progress in reducing the burden of neonatal and fetal death in Malawi will be partly predicated on guaranteeing properly equipped and

  8. Results of Survey Regarding Prevalence of Adventitial Infections in Mice and Rats at Biomedical Research Facilities.

    Science.gov (United States)

    Marx, James O; Gaertner, Diane J; Smith, Abigail L

    2017-09-01

    Control of rodent adventitial infections in biomedical research facilities is of extreme importance in assuring both animal welfare and high-quality research results. Sixty-three U.S. institutions participated in a survey reporting the methods used to detect and control these infections and the prevalence of outbreaks from 1 January 2014 through 31 December 2015. These results were then compared with the results of 2 similar surveys published in 1998 and 2008. The results of the current survey demonstrated that the rate of viral outbreaks in mouse colonies was decreasing, particularly in barrier facilities, whereas the prevalence of parasitic outbreaks has remained constant. These results will help our profession focus its efforts in the control of adventitial rodent disease outbreaks to the areas of the greatest needs.

  9. Survey of solar thermal test facilities

    Energy Technology Data Exchange (ETDEWEB)

    Masterson, K.

    1979-08-01

    The facilities that are presently available for testing solar thermal energy collection and conversion systems are briefly described. Facilities that are known to meet ASHRAE standard 93-77 for testing flat-plate collectors are listed. The DOE programs and test needs for distributed concentrating collectors are identified. Existing and planned facilities that meet these needs are described and continued support for most of them is recommended. The needs and facilities that are suitable for testing components of central receiver systems, several of which are located overseas, are identified. The central contact point for obtaining additional details and test procedures for these facilities is the Solar Thermal Test Facilities Users' Association in Albuquerque, N.M. The appendices contain data sheets and tables which give additional details on the technical capabilities of each facility. Also included is the 1975 Aerospace Corporation report on test facilities that is frequently referenced in the present work.

  10. Survey of active and inactive mines for possible use as in situ test facilities

    International Nuclear Information System (INIS)

    1976-09-01

    A survey of active and inactive mines which might be useful for radioactive waste storage in situ test experiments was conducted. It was performed for Union Carbide Corporation, Nuclear Division, Office of Waste Isolation. The report covers available information gathered from literature, U.S. Bureau of Mines, the Mining Enforcement and Safety Agency, and a limited number of personal contacts with constructors or operators of facilities. This survey is preliminary in nature and the objective is to develop potential candidate facilities for in situ experiments which warrant further investigation. Included are descriptions of 244 facilities, with all the data about each one which was available within the time restraint of the study. These facility descriptions are additionally indexed by depth of mine, nature of the country rock, mineral mined, and type of entry. A total of 14 inactive mines and 34 active mines has been selected as those most worthy of further investigation for possible service as nuclear waste isolation test facilities. This investigation, being preliminary and having been performed in a very short time period, must be qualified, and the description of the qualification is presented in the body of this report. Qualifications deal primarily with the hazard of having omitted facilities and having incomplete data in some instances. Results indicate sedimentary rock mines of minerals of evaporite origin as a first ranking of preference for in situ testing, followed by other sedimentary rocks and then by mines producing minerals from any type rock where the mine is above the local water table. These are general rules and of course there can be exceptions to them

  11. Classification of High-Rise Residential Building Facilities: A Descriptive Survey on 170 Housing Scheme in Klang Valley

    Directory of Open Access Journals (Sweden)

    Abd Wahab Siti Rashidah Hanum

    2016-01-01

    Full Text Available High-rise residential building is a type of housing that has multi-dwelling units built on the same land. This type of housing has become popular each year in urban area due to the increasing cost of land. There are several common facilities provided in high-rise residential building. For example playground, swimming pool, gymnasium, 24 hours security system such as CCTV, access card and so on. Thus, maintenance works of the common facilities must be well organised. The purpose of this paper is to identify the classification of facilities provided at high rise residential building. The survey was done on 170 high-rise residential schemes by using stratified random sampling technique. The scope of this research is within Klang Valley area. This area is rapidly developed with high-rise residential building. The objective of this survey is to list down all the facilities provided in each sample of the schemes. The result, there are nine classification of facilities provided for high-rise residential building.

  12. Survey of neutron radiography facilities

    International Nuclear Information System (INIS)

    Imel, G.R.; McClellan, G.G.

    1996-01-01

    A directory of neutron radiography facilities around the world was informally compiled about ten years ago under the auspices of the American Society for Testing and Materials (ASTM), Subcommittee E7.05 (Radiology, Neutron). The work lay dormant for a number of years, but was revived in earnest in the fall of 1995. At that time, letters were mailed to all the facilities with available addresses in the original directory, requesting updated information. Additionally, information was gathered at the Second Topical meeting on neutron Radiography Facility System Design and Beam Characterization (November, 1995, Shonan Village, Japan). A second mailing was sent for final confirmation and updates in January, 1996. About 75% of the information in the directory has now been confirmed by the facility management. This paper presents a summary of the information contained in the facility directory. An electronic version of the directory in Wordperfect 6.1, uuencode, or rtf format is available by sending e-mail to the authors at imel at sign anl.gov or imel at sign baobab.cad.cea.fr. A WWW site for the directory is presently under construction

  13. Assessment of human resources for health using cross-national comparison of facility surveys in six countries

    Directory of Open Access Journals (Sweden)

    Dal Poz Mario R

    2009-03-01

    Full Text Available Abstract Background Health facility assessments are being increasingly used to measure and monitor indicators of health workforce performance, but the global evidence base remains weak. Partly this is due to the wide variability in assessment methods and tools, hampering comparability across and within countries and over time. The World Health Organization coordinated a series of facility-based surveys using a common approach in six countries: Chad, Côte d'Ivoire, Jamaica, Mozambique, Sri Lanka and Zimbabwe. The objectives were twofold: to inform the development and monitoring of human resources for health (HRH policy within the countries; and to test and validate the use of standardized facility-based human resources assessment tools across different contexts. Methods The survey methodology drew on harmonized questionnaires and guidelines for data collection and processing. In accordance with the survey's dual objectives, this paper presents both descriptive statistics on a number of policy-relevant indicators for monitoring and evaluation of HRH as well as a qualitative assessment of the usefulness of the data collection tool for comparative analyses. Results The findings revealed a large diversity in both the organization of health services delivery and, in particular, the distribution and activities of facility-based health workers across the sampled countries. At the same time, some commonalities were observed, including the importance of nursing and midwifery personnel in the skill mix and the greater tendency of physicians to engage in dual practice. While the use of standardized questionnaires offered the advantage of enhancing cross-national comparability of the results, some limitations were noted, especially in relation to the categories used for occupations and qualifications that did not necessarily conform to the country situation. Conclusion With increasing experience in health facility assessments for HRH monitoring comes

  14. Linking household and health facility surveys to assess obstetric service availability, readiness and coverage: evidence from 17 low- and middle-income countries.

    Science.gov (United States)

    Kanyangarara, Mufaro; Chou, Victoria B; Creanga, Andreea A; Walker, Neff

    2018-06-01

    Improving access and quality of obstetric service has the potential to avert preventable maternal, neonatal and stillborn deaths, yet little is known about the quality of care received. This study sought to assess obstetric service availability, readiness and coverage within and between 17 low- and middle-income countries. We linked health facility data from the Service Provision Assessments and Service Availability and Readiness Assessments, with corresponding household survey data obtained from the Demographic and Health Surveys and Multiple Indicator Cluster Surveys. Based on performance of obstetric signal functions, we defined four levels of facility emergency obstetric care (EmOC) functionality: comprehensive (CEmOC), basic (BEmOC), BEmOC-2, and low/substandard. Facility readiness was evaluated based on the direct observation of 23 essential items; facilities "ready to provide obstetric services" had ≥20 of 23 items available. Across countries, we used medians to characterize service availability and readiness, overall and by urban-rural location; analyses also adjusted for care-seeking patterns to estimate population-level coverage of obstetric services. Of the 111 500 health facilities surveyed, 7545 offered obstetric services and were included in the analysis. The median percentages of facilities offering EmOC and "ready to provide obstetric services" were 19% and 10%, respectively. There were considerable urban-rural differences, with absolute differences of 19% and 29% in the availability of facilities offering EmOC and "ready to provide obstetric services", respectively. Adjusting for care-seeking patterns, results from the linking approach indicated that among women delivering in a facility, a median of 40% delivered in facilities offering EmOC, and 28% delivered in facilities "ready to provide obstetric services". Relatively higher coverage of facility deliveries (≥65%) and coverage of deliveries in facilities "ready to provide obstetric

  15. Independent Confirmatory Survey Summary and Results for the Plum Brook Reactor Facility Sandusky OH

    International Nuclear Information System (INIS)

    Bailey, E.N.

    2008-01-01

    In 1941, the War Department acquired approximately 9,000 acres of land near Sandusky, Ohio and constructed a munitions plant. The Plum Brook Ordnance Works Plant produced munitions, such as TNT, until the end of World War II. Following the war, the land remained idle until the National Advisory Committee for Aeronautics (later known as the National Aeronautics and Space Administration or NASA) obtained 500 acres to construct a nuclear research reactor designed to study the effects of radiation on materials used in space flight. The research reactor was put into operation in 1961 and was the first of fifteen test facilities eventually built by NASA at the Plum Brook Station. By 1963, NASA had acquired the remaining land at Plum Brook for these additional test facilities. After successfully completing the objective of landing humans on the Moon and returning them safely to Earth, NASA was faced with budget reductions from Congress in 1973. These budgetary constraints caused NASA to cease operations at several research facilities across the country, including those at Plum Brook Station. The major test facilities at Plum Brook were maintained in a standby mode, capable of being reactivated for future use. The Plum Brook Reactor Facility (PBRF) was shut down January 5, 1973 and all of the nuclear fuel was eventually removed and shipped off site to a U.S. Department of Energy facility in Idaho for disposal or reuse. Decommissioning activities are currently underway at the PBRF (NASA 1999). The objectives of the confirmatory survey activities were to provide independent contractor field data reviews and to generate independent radiological data for use by the Nuclear Regulatory Commission (NRC) in evaluating the adequacy and accuracy of the licensee's procedures and final status survey (FSS) results

  16. Test program element II blanket and shield thermal-hydraulic and thermomechanical testing, experimental facility survey

    Energy Technology Data Exchange (ETDEWEB)

    Ware, A.G.; Longhurst, G.R.

    1981-12-01

    This report presents results of a survey conducted by EG and G Idaho to determine facilities available to conduct thermal-hydraulic and thermomechanical testing for the Department of Energy Office of Fusion Energy First Wall/Blanket/Shield Engineering Test Program. In response to EG and G queries, twelve organizations (in addition to EG and G and General Atomic) expressed interest in providing experimental facilities. A variety of methods of supplying heat is available.

  17. Test program element II blanket and shield thermal-hydraulic and thermomechanical testing, experimental facility survey

    International Nuclear Information System (INIS)

    Ware, A.G.; Longhurst, G.R.

    1981-12-01

    This report presents results of a survey conducted by EG and G Idaho to determine facilities available to conduct thermal-hydraulic and thermomechanical testing for the Department of Energy Office of Fusion Energy First Wall/Blanket/Shield Engineering Test Program. In response to EG and G queries, twelve organizations (in addition to EG and G and General Atomic) expressed interest in providing experimental facilities. A variety of methods of supplying heat is available

  18. Healthcare worker and family caregiver hand hygiene in Bangladeshi healthcare facilities: results from the Bangladesh National Hygiene Baseline Survey.

    Science.gov (United States)

    Horng, L M; Unicomb, L; Alam, M-U; Halder, A K; Shoab, A K; Ghosh, P K; Opel, A; Islam, M K; Luby, S P

    2016-11-01

    Healthcare facility hand hygiene impacts patient care, healthcare worker safety, and infection control, but low-income countries have few data to guide interventions. To conduct a nationally representative survey of hand hygiene infrastructure and behaviour in Bangladeshi healthcare facilities to establish baseline data to aid policy. The 2013 Bangladesh National Hygiene Baseline Survey examined water, sanitation, and hand hygiene across households, schools, restaurants and food vendors, traditional birth attendants, and healthcare facilities. We used probability proportional to size sampling to select 100 rural and urban population clusters, and then surveyed hand hygiene infrastructure in 875 inpatient healthcare facilities, observing behaviour in 100 facilities. More than 96% of facilities had 'improved' water sources, but environmental contamination occurred frequently around water sources. Soap was available at 78-92% of handwashing locations for doctors and nurses, but just 4-30% for patients and family. Only 2% of 4676 hand hygiene opportunities resulted in recommended actions: using alcohol sanitizer or washing both hands with soap, then drying by air or clean cloth. Healthcare workers performed recommended hand hygiene in 9% of 919 opportunities: more after patient contact (26%) than before (11%). Family caregivers frequently washed hands with only water (48% of 2751 opportunities), but with little soap (3%). Healthcare workers had more access to hand hygiene materials and performed better hand hygiene than family, but still had low adherence. Increasing hand hygiene materials and behaviour could improve infection control in Bangladeshi healthcare facilities. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. A survey of decontamination processes applicable to DOE nuclear facilities

    International Nuclear Information System (INIS)

    Chen, L.; Chamberlain, D.B.; Conner, C.; Vandegrift, G.F.

    1997-05-01

    The objective of this survey was to select an appropriate technology for in situ decontamination of equipment interiors as part of the decommissioning of U.S. Department of Energy nuclear facilities. This selection depends on knowledge of existing chemical decontamination methods. This report provides an up-to-date review of chemical decontamination methods. According to available information, aqueous systems are probably the most universally used method for decontaminating and cleaning metal surfaces. We have subdivided the technologies, on the basis of the types of chemical solvents, into acid, alkaline permanganate, highly oxidizing, peroxide, and miscellaneous systems. Two miscellaneous chemical decontamination methods (electrochemical processes and foam and gel systems) are also described. A concise technical description of various processes is given, and the report also outlines technical considerations in the choice of technologies, including decontamination effectiveness, waste handing, fields of application, and the advantages and limitations in application. On the basis of this survey, six processes were identified for further evaluation. 144 refs., 2 tabs

  20. A survey of decontamination processes applicable to DOE nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Chen, L.; Chamberlain, D.B.; Conner, C.; Vandegrift, G.F.

    1997-05-01

    The objective of this survey was to select an appropriate technology for in situ decontamination of equipment interiors as part of the decommissioning of U.S. Department of Energy nuclear facilities. This selection depends on knowledge of existing chemical decontamination methods. This report provides an up-to-date review of chemical decontamination methods. According to available information, aqueous systems are probably the most universally used method for decontaminating and cleaning metal surfaces. We have subdivided the technologies, on the basis of the types of chemical solvents, into acid, alkaline permanganate, highly oxidizing, peroxide, and miscellaneous systems. Two miscellaneous chemical decontamination methods (electrochemical processes and foam and gel systems) are also described. A concise technical description of various processes is given, and the report also outlines technical considerations in the choice of technologies, including decontamination effectiveness, waste handing, fields of application, and the advantages and limitations in application. On the basis of this survey, six processes were identified for further evaluation. 144 refs., 2 tabs.

  1. Cross-sectional Survey of Long-Term Care Facilities in the Rockaway Peninsula: Preparedness and Response During Hurricane Sandy.

    Science.gov (United States)

    Jiang, Lynn; Tedeschi, Christopher; Subaiya, Saleena

    2018-04-01

    Few studies have described the challenges experienced by long-term care facilities (LTCFs) following Hurricane Sandy. This study examined LTCF preparedness and experiences during and after the storm. A cross-sectional survey was conducted 2 years after Hurricane Sandy to assess LTCF demographics, preparation, and post-storm resources. Surveys were conducted at LTCFs located on the Rockaway Peninsula of New York City. All LTCFs located in a heavily affected area were approached. Of 29 facilities, 1 had closed, 5 did not respond, 9 declined to participate, and 14 participated, yielding a response rate of 50% for open facilities. Twenty-one percent of the facilities had preparations specifically for hurricanes. More than 70% of the facilities had lost electricity, heat, and telephone service, and one-half had evacuated. Twenty-one percent of the facilities reported not receiving any assistance and over one-half reported that relief resources did not meet their needs. Many LTCFs lacked plans specific to such a large-scale event. Since nearly all of the LTCFs in the region were affected, preexisting transportation and housing plans may have been inadequate. Future preparation could include hazard-specific planning and reliance on resources from a wider geographic area. Access to electricity emerged as a top priority. (Disaster Med Public Health Preparedness. 2018;12:194-200).

  2. Questionnaire survey report about the criticality accident at a nuclear fuel processing facility

    International Nuclear Information System (INIS)

    2000-01-01

    The Radiation Protection Section of the Japanese Society of Radiological Technology conducted a questionnaire survey on the criticality accident at the nuclear fuel processing facility in Tokai village on September 30, 1999 in order to identify factors related to the accident and consider countermeasures to deal with such accidents. The questionnaire was distributed to 347 members (122 facilities) of the Japanese Society of Radiological Technology who were working or living in Ibaraki Prefecture, and replies were obtained from 104 members (75 facilities). Questions to elicit the opinions of individuals were as following: method of obtaining information about the accident, knowledge about radiation, opinions about the accident, and requests directed to the Society. Questions regarding facilities concerned the following: communication after the accident, requests for dispatch to the accident site, and possession of radiometry devices. In regard to acquisition of information, 91 of the 104 members (87.5%) answered 'television or radios' followed by newspapers. Forty-five of 101 members were questioned about radiation exposure and radiation effects by the public. There were many opinions that accurate news should be provided rapidly, by the mass media. Many members (75%) felt that they lacked knowledge about radiation, reconfirming the importance of education and instruction concerning radiation. Dispatch was requested of 36 of the 75 facilities (48%), and 44 of 83 facilities (53%) owned radiometry instruments. (K.H.)

  3. Ecological survey for the siting of the Mixed and Low-Level Waste Disposal Facility

    International Nuclear Information System (INIS)

    Hoskinson, R.L.

    1994-05-01

    This report summarizes the results of field ecological surveys conducted by the Center for Integrated Environmental Technologies (CIET) on the Idaho National Engineering Lab. (INEL) at two candidate locations for the siting of the Mixed and Low-Level Waste Disposal Facility (MLLWDF). The purpose of these surveys was to comply with all Federal laws and Executive Orders to identify and evaluate any potential environmental impacts because of the project. The boundaries of the candidate locations were marked with blaze-orange lath survey marker stakes by the project management. Global Positioning in System (GPS) measurements of the marker stakes were made, and input to the Arc/Info geographic information system (GIS). Field surveys were conducted to assess any potential impact to any important species, important habitats, and to any environmental study areas. The GIS location data were overlayed onto the INEL vegetation map and an analysis of vegetation classes on the locations was done. Two species of rare vascular plants have previously been reported to occur in the vicinity of the candidate locations. Two C2 species, the ferruginous hawk (Buteo regalis) and the loggerhead shrike (Lanius ludovicianus) would also be expected to frequent the candidate locations. No significant ecological impact is anticipated if the MLLWDF were constructed on either candidate location. However, both candidate locations are in the central area of the INEL where there is minimal disturbance to the ecosystem by facilities or humans

  4. Improving children's nutrition environments: A survey of adoption and implementation of nutrition guidelines in recreational facilities

    Directory of Open Access Journals (Sweden)

    Downs Shauna M

    2011-06-01

    Full Text Available Abstract Background Although the mandate of recreational facilities is to enhance well-being, many offer foods inconsistent with recommendations for healthy eating. Little is known regarding recreational facility food environments and how they might be improved, as few studies exist. The Alberta Nutrition Guidelines for Children and Youth (ANGCY are intended to ensure access to healthy food choices in schools, childcare and recreational facilities. This study investigated awareness, adoption and implementation of the ANGCY among recreational facilities in Alberta, Canada, one year following their release. Methods A cross-sectional telephone survey was conducted from June - December, 2009 (n = 151 with managers of publicly funded recreational facilities that served food. The questionnaire included 10 closed and 7 open ended questions to assess the organizational priority for healthy eating, awareness, adoption and implementation of the ANGCY. Chi-squared tests examined quantitative variables, while qualitative data were analysed using directed content analysis. Greenhalgh's model of diffusion of complex innovations within health service organizations constituted the theoretical framework for the study. Results One half of respondents had heard of the ANGCY, however their knowledge of them was limited. Although 51% of facilities had made changes to improve the nutritional quality of foods offered in the past year, only a small fraction (11% of these changes were motivated by the ANGCY. At the time of the survey, 14% of facilities had adopted the ANGCY and 6% had implemented them. Barriers to adoption and implementation were primarily related to perceived negative attributes of the ANGCY, the inner (organizational context, and negative feedback received during the implementation process. Managers strongly perceived that implementing nutrition guidelines would limit their profit-making ability. Conclusions If fully adopted and implemented, the ANGCY

  5. Birth in a health facility--inequalities among the Ethiopian women: results from repeated national surveys.

    Directory of Open Access Journals (Sweden)

    Elias Ali Yesuf

    Full Text Available BACKGROUND: Uptake of health facilities for delivery care in Ethiopia has not been examined in the light of equality. We investigated differences in institutional deliveries by urbanity, administrative region, economic status and maternal education. METHODS: This study was based on nation-wide repeated surveys undertaken in the years 2000, 2005, and 2011. The surveys used a cluster sampling design. Women of reproductive age were interviewed on the place of their last delivery. Data was analyzed using logistic regressions to estimate the weighted association between birth in a health facility and study's predictors. RESULTS: Utilization of health institutions for deliveries has improved throughout the study period, however, rates remain low (5.4%,2000 and 11.8%,2011. Compared with women from rural places, women from urban areas had independent OR of a health facility delivery of 4.9 (95% CI: 3.4, 7.0, 5.0 (95% CI: 3.6, 6.9, and 4.6 (95% CI: 3.5, 6.0 in 2000, 2005, and 2011, respectively. Women with secondary/higher education had more deliveries in a healthcare facility than women with no education, and these gaps widened over the years (OR: 35.1, 45.0 and 53.6 in 2000, 2005, and 2011, respectively. Women of the upper economic quintile had 3.0-7.2 times the odds of healthcare facility deliveries, compared with the lowest quintile, with no clear trend over the years. While Addis-Ababa and Dire Dawa remained with the highest OR for deliveries in a health facility compared with Amhara, other regions displayed shifts in their relative ranking with Oromiya, SNNPR, Afar, Harari, and Somali getting relatively worse over time. CONCLUSIONS: The disparity related to urbanity or education in the use of health facility for birth in Ethiopia is staggering. There is a small inequality between most regions except Addis Ababa/Dire Dawa and sign of abating inequity between economic strata except for the richest households.

  6. A Global Survey and Interactive Map Suite of Deep Underground Facilities; Examples of Geotechnical and Engineering Capabilities, Achievements, Challenges: (Mines, Shafts, Tunnels, Boreholes, Sites and Underground Facilities for Nuclear Waste and Physics R&D)

    Science.gov (United States)

    Tynan, M. C.; Russell, G. P.; Perry, F.; Kelley, R.; Champenois, S. T.

    2017-12-01

    This global survey presents a synthesis of some notable geotechnical and engineering information reflected in four interactive layer maps for selected: 1) deep mines and shafts; 2) existing, considered or planned radioactive waste management deep underground studies, sites, or disposal facilities; 3) deep large diameter boreholes, and 4) physics underground laboratories and facilities from around the world. These data are intended to facilitate user access to basic information and references regarding deep underground "facilities", history, activities, and plans. In general, the interactive maps and database [http://gis.inl.gov/globalsites/] provide each facility's approximate site location, geology, and engineered features (e.g.: access, geometry, depth, diameter, year of operations, groundwater, lithology, host unit name and age, basin; operator, management organization, geographic data, nearby cultural features, other). Although the survey is not all encompassing, it is a comprehensive review of many of the significant existing and historical underground facilities discussed in the literature addressing radioactive waste management and deep mined geologic disposal safety systems. The global survey is intended to support and to inform: 1) interested parties and decision makers; 2) radioactive waste disposal and siting option evaluations, and 3) safety case development as a communication tool applicable to any mined geologic disposal facility as a demonstration of historical and current engineering and geotechnical capabilities available for use in deep underground facility siting, planning, construction, operations and monitoring.

  7. Aerial radiological survey of the United States Department of Energy's Battelle Nuclear Science Facility, West Jefferson, Ohio, date of survey: May 1977

    International Nuclear Information System (INIS)

    Feimster, E.L.

    1979-05-01

    An aerial radiological survey to measure terrestrial gamma radiation was carried out over the United States Department of Energy's Battelle Nuclear Science Facility located in West Jefferson, Ohio. Gamma ray data were collected over a 5.5 km 2 area centered on the facility by flying east-west lines spaced 61 m apart. Processed data indicated that on-site radioactivity was primarily due to radionuclides currently being processed due to the hot lab operations. Off-site data showed the radioactivity to be due to naturally occurring background radiation consistent with variations due to geologic base terrain and land use of similar areas

  8. Use of a Balanced Scorecard in strengthening health systems in developing countries: an analysis based on nationally representative Bangladesh Health Facility Survey.

    Science.gov (United States)

    Khan, M Mahmud; Hotchkiss, David R; Dmytraczenko, Tania; Zunaid Ahsan, Karar

    2013-01-01

    This paper illustrates the importance of collecting facility-based data through regular surveys to supplement the administrative data, especially for developing countries of the world. In Bangladesh, measures based on facility survey indicate that only 70% of very basic medical instruments and 35% of essential drugs were available in health facilities. Less than 2% of officially designated obstetric care facilities actually had required drugs, injections and personnel on-site. Majority of (80%) referral hospitals at the district level were not ready to provide comprehensive emergency obstetric care. Even though the Management Information System reports availability of diagnostic machines in all district-level and sub-district-level facilities, it fails to indicate that 50% of these machines are not functional. In terms of human resources, both physicians and nurses are in short supply at all levels of the healthcare system. The physician-nurse ratio also remains lower than the desirable level of 3.0. Overall job satisfaction index was less than 50 for physicians and 66 for nurses. Patient satisfaction score, however, was high (86) despite the fact that process indicators of service quality were poor. Facility surveys can help strengthen not only the management decision-making process but also the quality of administrative data. Copyright © 2012 John Wiley & Sons, Ltd.

  9. Questionnaire survey and technical guideline of blood irradiation on medical facilities

    International Nuclear Information System (INIS)

    Matsumoto, Mitsuhiro; Hasegawa, Hironori; Okumura, Masahiko; Sonoda, Tatsuo; Osada, Koji.

    1997-01-01

    We know that transfusion-associated graft versus host disease (TA-GVHD) is a serious side effect associated with blood transfusion and the onset is independent on the immunological conditions of patients. We have only prophylactic treatment against TA-GVHD. The most reliable method is to irradiate the blood for transfusion. In Japanese medical facilities, however, the risk of TA-GVHD is poorly understood and actual conditions of the blood irradiation are unclear. We sent a questionnaire to randomly selected 426 medical facilities in Japan, which had the department of radiology, to investigate the actual conditions of blood irradiation for transfusion and the problems on the irradiation dose measurement of the external apparatus for blood irradiation. The questionnaire involved 19 questions about the blood irradiation for transfusion. The survey took place for one month (June 1-June 30, 1995). Replies were obtained from a total of 306 medical facilities (72%). The results showed that blood irradiation was done by several methods in the 75% of the medical facilities, and the external irradiation apparatus was used in 83%. Some problems were shown, including irradiation period, cost of the irradiation, the operating procedure of the apparatus, requested number of the irradiation, and the request after usual hours. There was no significant problem on the irradiation dose, irradiation method, etc. We also sent a questionnaire to 74 facilities of the Red Cross Blood Center, in which the frequency of blood irradiation have increased since May, 1976. The X-ray apparatus as the external irradiation apparatus has practical advantages; lower cost, compact and out of the legal control on the ionizing radiation, however, it has some problems on the uniformity of the absorption dose when a single X-ray tube-type apparatus is used. We discuss about the possible onset of TA-GVHD or other accidents by the incorrect irradiation of the blood preparations. (K.H.)

  10. Radiological survey of the former Kellex Research Facility, Jersey City, New Jersey

    International Nuclear Information System (INIS)

    Berven, B.A.; Dickson, H.W.; Goldsmith, W.A.; Johnson, W.M.; Cottrell, W.D.; Doane, R.W.; Haywood, F.F.; Ryan, M.T.; Shinpaugh, W.H.

    1982-02-01

    A radiological survey has been conducted at the site of the former Kellex Corporation Research Facility in Jersey City, New Jersey. Kellex played a major role in the Manhattan Project, particularly in the area of engineering research in gaseous diffusion for uranium enrichment. As a result of those operations and subsequent work with radioactive materials, this site was selected for a radiological survey by the Department of Energy (DOE) [then Energy Research and Development Administration (ERDA)] in its program aimed at reviewing and documenting the radiological status of properties associated with early source material contracts. The survaty included measurement of external gamma radiation, beta-gamma surface dose rates, alpha and beta surface contamination, concentrations of selected radionuclides in surface and subsurface soil and water on the site, and background radiation in the northern part of New Jersey. The results of the radiological survey indicate radionuclide concentrations in the soil and water on the former Kellex property are within background levels, with the exception of nine isolated and well-defined areas on the site of the former Kellex Laboratory

  11. Archive of Geosample Information from the Geological Survey of Canada Atlantic (GSC A) Marine Geoscience Curation Facility

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Geological Survey of Canada Atlantic (GSC A) Marine Geoscience Curation Facility contributed information on 40,428 cores, grabs, and dredges in their holdings to...

  12. Survey of radioactive effluent releases from byproduct material facilities. Technical report

    International Nuclear Information System (INIS)

    Cook, J.R.

    1981-08-01

    A survey of over 3,000 NRC byproduct material licensees was conducted in late 1980 to collect data on annual effluent releases of radioactivity. The survey was conducted through a questionnaire, which was sent to NRC licensees who handle radioactive material in unsealed form, i.e., research, medical, and industrial institutions. Principal findings from the survey analysis are as follows: More than 98% of the reported annual releases to air (484 to 490) yield calculated average concentrations at the boundary of the unrestricted area that were at 1% or less than the maximum permissible concentration (MPC) of Appendix B, Table II, Column 1 of 10 CFR 20. The largest reported annual release was estimated to yield a concentration that was approximately 12% of MPC, the 5 other releases ranged from 1 to 10% of MPC. All reported annual releases of liquid waste were within the limits specified by NRC with most facilities reporting annual releases of only a fraction of a curie. Based on the data provided by licensees and analyzed in this report, it appears that in general the environmental impacts from research, medical and industrial institutions and organizations licensed by the NRC to possess and use byproduct materials are minimal and correspond to a small fraction of that from natural background

  13. The state of emergency obstetric care services in Nairobi informal settlements and environs: Results from a maternity health facility survey

    Directory of Open Access Journals (Sweden)

    Saliku Teresa

    2009-03-01

    Full Text Available Abstract Background Maternal mortality in Sub-Saharan Africa remains a challenge with estimates exceeding 1,000 maternal deaths per 100,000 live births in some countries. Successful prevention of maternal deaths hinges on adequate and quality emergency obstetric care. In addition to skilled personnel, there is need for a supportive environment in terms of essential drugs and supplies, equipment, and a referral system. Many household surveys report a reasonably high proportion of women delivering in health facilities. However, the quality and adequacy of facilities and personnel are often not assessed. The three delay model; 1 delay in making the decision to seek care; 2 delay in reaching an appropriate obstetric facility; and 3 delay in receiving appropriate care once at the facility guided this project. This paper examines aspects of the third delay by assessing quality of emergency obstetric care in terms of staffing, skills equipment and supplies. Methods We used data from a survey of 25 maternity health facilities within or near two slums in Nairobi that were mentioned by women in a household survey as places that they delivered. Ethical clearance was obtained from the Kenya Medical Research Institute. Permission was also sought from the Ministry of Health and the Medical Officer of Health. Data collection included interviews with the staff in-charge of maternity wards using structured questionnaires. We collected information on staffing levels, obstetric procedures performed, availability of equipment and supplies, referral system and health management information system. Results Out of the 25 health facilities, only two met the criteria for comprehensive emergency obstetric care (both located outside the two slums while the others provided less than basic emergency obstetric care. Lack of obstetric skills, equipment, and supplies hamper many facilities from providing lifesaving emergency obstetric procedures. Accurate estimation of burden

  14. Indicators to examine quality of large scale survey data: an example through district level household and facility survey.

    Directory of Open Access Journals (Sweden)

    Kakoli Borkotoky

    Full Text Available BACKGROUND: Large scale surveys are the main source of data pertaining to all the social and demographic indicators, hence its quality is also of great concern. In this paper, we discuss the indicators used to examine the quality of data. We focus on age misreporting, incompleteness and inconsistency of information; and skipping of questions on reproductive and sexual health related issues. In order to observe the practical consequences of errors in a survey; the District Level Household and Facility Survey (DLHS-3 is used as an example dataset. METHODS: Whipple's and Myer's indices are used to identify age misreporting. Age displacements are identified by estimating downward and upward transfers for women from bordering age groups of the eligible age range. Skipping pattern is examined by recording the responses to the questions which precede the sections on birth history, immunization, and reproductive and sexual health. RESULTS: The study observed errors in age reporting, in all the states, but the extent of misreporting differs by state and individual characteristics. Illiteracy, rural residence and poor economic condition are the major factors that lead to age misreporting. Female were excluded from the eligible age group, to reduce the duration of interview. The study further observed that respondents tend to skip questions on HIV/RTI and other questions which follow a set of questions. CONCLUSION: The study concludes that age misreporting, inconsistency and incomplete response are three sources of error that need to be considered carefully before drawing conclusions from any survey. DLHS-3 also suffers from age misreporting, particularly for female in the reproductive ages. In view of the coverage of the survey, it may not be possible to control age misreporting completely, but some extra effort to probe a better answer may help in improving the quality of data in the survey.

  15. Evaluation of case management of uncomplicated malaria in Haiti: a national health facility survey, 2012.

    Science.gov (United States)

    Landman, Keren Z; Jean, Samuel E; Existe, Alexandre; Akom, Eniko E; Chang, Michelle A; Lemoine, Jean Frantz; Mace, Kimberly E

    2015-10-09

    Malaria is a public health concern in Haiti, although there are limited data on its burden and case management. National malaria guidelines updated in 2012 recommend treatment with chloroquine and primaquine. In December 2012, a nationally-representative cross-sectional survey of health facilities (HFs) was conducted to determine malaria prevalence among febrile outpatients and malaria case management quality at baseline before scale-up of diagnostics and case management training. Among all 833 HFs nationwide, 30 were selected randomly, in proportion to total HFs per region, for 2-day evaluations. Survey teams inventoried HF material and human resources. Outpatients of all ages were screened for temperature >37.5 °C or history of fever; those without severe symptoms were consented and enrolled. Providers evaluated and treated enrolled patients according to HF standards; the survey teams documented provider-ordered diagnostic tests and treatment decisions. Facility-based test results [microscopy and malaria rapid diagnostic tests (RDTs)] were collected from HF laboratories. Blood smears for gold-standard microscopy, and dried blood spots for polymerase chain reaction (PCR) were obtained. Malaria diagnostic capacity, defined as completing a test for an enrolled patient or having adequate resources for RDTs or microscopy, was present in 11 (37 %) HFs. Among 459 outpatients screened, 257 (56 %) were febrile, of which 193 (75 %) were eligible, and 153 (80 %) were enrolled. Among 39 patients with facility-level malaria test results available on the survey day, 11 (28 %) were positive, of whom 6 (55 %) were treated with an anti-malarial. Twenty-seven (95 %) of the 28 patients testing negative were not treated with an anti-malarial. Of 114 patients without test results available, 35 (31 %) were presumptively treated for malaria. Altogether, 42 patients were treated with an anti-malarial, one (2 %) according to Haiti's 2012 guidelines. Of 140 gold-standard smears, none

  16. Facility-Based Delivery during the Ebola Virus Disease Epidemic in Rural Liberia: Analysis from a Cross-Sectional, Population-Based Household Survey.

    Directory of Open Access Journals (Sweden)

    John Ly

    2016-08-01

    Full Text Available The Ebola virus disease (EVD epidemic has threatened access to basic health services through facility closures, resource diversion, and decreased demand due to community fear and distrust. While modeling studies have attempted to estimate the impact of these disruptions, no studies have yet utilized population-based survey data.We conducted a two-stage, cluster-sample household survey in Rivercess County, Liberia, in March-April 2015, which included a maternal and reproductive health module. We constructed a retrospective cohort of births beginning 4 y before the first day of survey administration (beginning March 24, 2011. We then fit logistic regression models to estimate associations between our primary outcome, facility-based delivery (FBD, and time period, defined as the pre-EVD period (March 24, 2011-June 14, 2014 or EVD period (June 15, 2014-April 13, 2015. We fit both univariable and multivariable models, adjusted for known predictors of facility delivery, accounting for clustering using linearized standard errors. To strengthen causal inference, we also conducted stratified analyses to assess changes in FBD by whether respondents believed that health facility attendance was an EVD risk factor. A total of 1,298 women from 941 households completed the survey. Median age at the time of survey was 29 y, and over 80% had a primary education or less. There were 686 births reported in the pre-EVD period and 212 in the EVD period. The unadjusted odds ratio of facility-based delivery in the EVD period was 0.66 (95% confidence interval [CI] 0.48-0.90, p-value = 0.010. Adjustment for potential confounders did not change the observed association, either in the principal model (adjusted odds ratio [AOR] = 0.70, 95%CI 0.50-0.98, p = 0.037 or a fully adjusted model (AOR = 0.69, 95%CI 0.50-0.97, p = 0.033. The association was robust in sensitivity analyses. The reduction in FBD during the EVD period was observed among those reporting a belief that

  17. Survey to identify depth of penetration of critical incident reporting systems in Austrian healthcare facilities.

    Science.gov (United States)

    Sendlhofer, Gerald; Eder, Harald; Leitgeb, Karina; Gorges, Roland; Jakse, Heidelinde; Raiger, Marianne; Türk, Silvia; Petschnig, Walter; Pregartner, Gudrun; Kamolz, Lars-Peter; Brunner, Gernot

    2018-01-01

    Incident reporting systems or so-called critical incident reporting systems (CIRS) were first recommended for use in health care more than 15 years ago. The uses of these CIRS are highly variable among countries, ranging from being used to report critical incidents, falls, or sentinel events resulting in death. In Austria, CIRS have only been introduced to the health care sector relatively recently. The goal of this work, therefore, was to determine whether and specifically how CIRS are used in Austria. A working group from the Austrian Society for Quality and Safety in Healthcare (ASQS) developed a survey on the topic of CIRS to collect information on penetration of CIRS in general and on how CIRS reports are used to increase patient safety. Three hundred seventy-one health care professionals from 274 health care facilities were contacted via e-mail. Seventy-eight respondents (21.0%) completed the online survey, thereof 66 from hospitals and 12 from other facilities (outpatient clinics, nursing homes). In all, 64.1% of the respondents indicated that CIRS were used in the entire health care facility; 20.6% had not yet introduced CIRS and 15.4% used CIRS only in particular areas. Most often, critical incidents without any harm to patients were reported (76.9%); however, some health care facilities also use their CIRS to report patient falls (16.7%), needle stick injuries (17.9%), technical problems (51.3%), or critical incidents involving health care professionals. CIRS are not yet extensively or homogeneously used in Austria. Inconsistencies exist with respect to which events are reported as well as how they are followed up and reported to health care professionals. Further recommendations for general use are needed to support the dissemination in Austrian health care environments.

  18. Special case waste located at Oak Ridge National Laboratory facilities: Survey report

    International Nuclear Information System (INIS)

    Forgy, J.R. Jr.

    1995-11-01

    Between October 1994 and October 1995, a data base was established at the Oak Ridge National Laboratory (ORNL) to provide a current inventory of the radioactive waste materials, located at ORNL, for which the US Department of Energy (DOE) has no definite planned disposal alternatives. DOE refers to these waste materials as special case waste. To assist ORNL and DOE management in future planning, an inventory system was established and a baseline inventory prepared. This report provides the background of the ORNL special case waste survey project, as well as special case waste category definitions, both current and anticipated sources and locations of special case waste materials, and the survey and data management processes. Special case waste will be that waste material which, no matter how much practical characterization, treatment, and packaging is made, will never meet the acceptance criteria for permanent disposal at ORNL, and does not meet the criteria at a currently planned off-site permanent disposal facility

  19. An aerial radiological survey of the Saxton Nuclear Experimental Corporation facility and surrounding area, Saxton, Pennsylvania

    International Nuclear Information System (INIS)

    Hoover, R.A.

    1991-10-01

    An aerial radiological survey was conducted during the period July 5 to 22, 1989, over an 83-square kilometer (32-square-mile) area surrounding the Saxton Nuclear Experimental Corporation (SNEC) facility which is owned by General Public Utilities and located near Saxton, Pennsylvania. The survey was conducted at a nominal altitude of 61 meters (200 feet) with line spacings of 91 meters (300 feet). A contour map of the terrestrial gamma exposure rate extrapolated to 1 meter above ground level (AGL) was prepared and overlaid on an aerial photograph and a set of United States Geological Survey (USGS) topographic maps of the area. The terrestrial exposure rates varied from about 9 to 11 microroentgens per hour (μR/h) over most of the survey area. The levels over the SNEC family did not differ from the exposure rates seen over the entire survey area. Cesium-137 (Cs-137) levels typical of worldwide fallout deposition were detected throughout the surveyed area. No other trends of Cs-137 were observed. Soil samples and pressurized ion chamber measurements were obtained at six locations within the survey boundaries to support the aerial data

  20. North Carolina Geological Survey's role in siting a low-level radioactive (LLRW) waste disposal facility in North Carolina

    International Nuclear Information System (INIS)

    Reid, J.C.; Wooten, R.M.; Farrell, K.M.

    1993-01-01

    The Southeast Compact Commission in 1986 selected North Carolina to host the Southeast's LLRW disposal facility for the next twenty years. The North Carolina Geological Survey (NCGS) for six years has played a major role in the State's efforts by contributing to legislation and administrative code, policy, technical oversight and surveillance and regulation as a member of the State's regulatory team. Future activities include recommendation of the adequacy of characterization and site performance pursuant to federal code, state general statutes and administrative code, and review of a license application. Staff must be prepared to present testimony and professional conclusions in court. The NCGS provides technical advice to the Division of Radiation Protection (DRP), the regulatory agency which will grant or deny a LLRW license. The NCGS has not participated in screening the state for potential sites to minimize bias. The LLRW Management Authority, a separate state agency siting the LLRW facility, hired a contractor to characterize potential sites and to write a license application. Organizational relationships enable the NCGS to assist the DRP in its regulatory role without conflict of interest. Disposal facilities must be sited to ensure safe disposal of LLRW. By law, the siting of a LLRW disposal facility is primarily a geological, rather than an engineering, effort. Federal and State statutes indicate a site must be licensable on its own merits. Engineered barriers cannot make a site licensable. The project is 3 years behind schedule and millions of dollars over budget. This indicates the uncertainty and complexity inherent in siting such as facility, the outcome of which cannot be predicted until site characterization is complete, the license application reviewed and the performance assessment evaluated. State geological surveys are uniquely qualified to overview siting of LLRW facilities because of technical expertise and experience in the state's geology

  1. Aespoe Hard Rock Laboratory. Ground magnetic survey at site for planned facility for calibration of borehole orientation equipment at Aespoe

    Energy Technology Data Exchange (ETDEWEB)

    Mattsson, Haakan (GeoVista AB (Sweden))

    2012-01-15

    This report presents survey description and results of ground magnetic measurements carried out by GeoVista AB at Aespoe in December, 2011. The purpose of the ground magnetic measurement was to measure variations in the earth magnetic field and to gain knowledge of the magnetization of the bedrock in an area where SKB plan to build a facility for calibration of equipment for measurements of borehole orientation. A total of 312 data points were collected along three survey lines, 104 points/profile. The data show nice and smooth variations that appear to be natural. There is a clear consistency of the magnetic field variations between the three survey lines, which indicates that the variations in the magnetic field reflect geological variations related to lithology and content of magnetic minerals. There are no indications of artifacts or erroneous data. The anomaly field averages at -32 nT with peak values of Min = -1,016 nT and Max = +572 nT. The strongest anomalies occur at profile length c. 130-140 m. Adding the background field of 50,823 nT, measured at a base station located close to the survey area, the total magnetic field averages at 50,791+-226 nT. The ground magnetic measurement gives background information before the construction of the calibration facility. The magnetic anomaly at c. 130-140 m give possibilities to control disturbances of magnetic-accelerometer based instruments. The magnetic measurements show that it is possible to construct the facility at the site

  2. Aespoe Hard Rock Laboratory. Ground magnetic survey at site for planned facility for calibration of borehole orientation equipment at Aespoe

    International Nuclear Information System (INIS)

    Mattsson, Haakan

    2012-01-01

    This report presents survey description and results of ground magnetic measurements carried out by GeoVista AB at Aespoe in December, 2011. The purpose of the ground magnetic measurement was to measure variations in the earth magnetic field and to gain knowledge of the magnetization of the bedrock in an area where SKB plan to build a facility for calibration of equipment for measurements of borehole orientation. A total of 312 data points were collected along three survey lines, 104 points/profile. The data show nice and smooth variations that appear to be natural. There is a clear consistency of the magnetic field variations between the three survey lines, which indicates that the variations in the magnetic field reflect geological variations related to lithology and content of magnetic minerals. There are no indications of artifacts or erroneous data. The anomaly field averages at -32 nT with peak values of Min = -1,016 nT and Max = +572 nT. The strongest anomalies occur at profile length c. 130-140 m. Adding the background field of 50,823 nT, measured at a base station located close to the survey area, the total magnetic field averages at 50,791±226 nT. The ground magnetic measurement gives background information before the construction of the calibration facility. The magnetic anomaly at c. 130-140 m give possibilities to control disturbances of magnetic-accelerometer based instruments. The magnetic measurements show that it is possible to construct the facility at the site

  3. Where do the rural poor deliver when high coverage of health facility delivery is achieved? Findings from a community and hospital survey in Tanzania.

    Directory of Open Access Journals (Sweden)

    Manuela Straneo

    Full Text Available As part of maternal mortality reducing strategies, coverage of delivery care among sub-Saharan African rural poor will improve, with a range of facilities providing services. Whether high coverage will benefit all socio-economic groups is unknown. Iringa rural District, Southern Tanzania, with high facility delivery coverage, offers a paradigm to address this question. Delivery services are available in first-line facilities (dispensaries, health centres and one hospital. We assessed whether all socio-economic groups access the only comprehensive emergency obstetric care facility equally, and surveyed existing delivery services.District population characteristics were obtained from a household community survey (n = 463. A Hospital survey collected data on women who delivered in this facility (n = 1072. Principal component analysis on household assets was used to assess socio-economic status. Hospital population socio-demographic characteristics were compared to District population using multivariable logistic regression. Deliveries' distribution in District facilities and staffing were analysed using routine data.Women from the hospital compared to the District population were more likely to be wealthier. Adjusted odds ratio of hospital delivery increased progressively across socio-economic groups, from 1.73 for the poorer (p = 0.0031 to 4.53 (p<0.0001 for the richest. Remarkable dispersion of deliveries and poor staffing were found. In 2012, 5505/7645 (72% institutional deliveries took place in 68 first-line facilities, the remaining in the hospital. 56/68 (67.6% first-line facilities reported ≤100 deliveries/year, attending 33% of deliveries. Insufficient numbers of skilled birth attendants were found in 42.9% of facilities.Poorer women remain disadvantaged in high coverage, as they access lower level facilities and are under-represented where life-saving transfusions and caesarean sections are available. Tackling the challenges

  4. Challenges in implementing uncomplicated malaria treatment in children: a health facility survey in rural Malawi.

    Science.gov (United States)

    Kabaghe, Alinune N; Phiri, Mphatso D; Phiri, Kamija S; van Vugt, Michèle

    2017-10-18

    Prompt and effective malaria treatment are key in reducing transmission, disease severity and mortality. With the current scale-up of artemisinin-based combination therapy (ACT) coverage, there is need to focus on challenges affecting implementation of the intervention. Routine indicators focus on utilization and coverage, neglecting implementation quality. A health system in rural Malawi was assessed for uncomplicated malaria treatment implementation in children. A cross-sectional health facility survey was conducted in six health centres around the Majete Wildlife Reserve in Chikwawa district using a health system effectiveness approach to assess uncomplicated malaria treatment implementation. Interviews with health facility personnel and exit interviews with guardians of 120 children under 5 years were conducted. Health workers appropriately prescribed an ACT and did not prescribe an ACT to 73% (95% CI 63-84%) of malaria rapid diagnostic test (RDT) positive and 98% (95% CI 96-100%) RDT negative children, respectively. However, 24% (95% CI 13-37%) of children receiving artemisinin-lumefantrine had an inappropriate dose by weight. Health facility findings included inadequate number of personnel (average: 2.1 health workers per 10,000 population), anti-malarial drug stock-outs or not supplied, and inconsistent health information records. Guardians of 59% (95% CI 51-69%) of children presented within 24 h of onset of child's symptoms. The survey presents an approach for assessing treatment effectiveness, highlighting bottlenecks which coverage indicators are incapable of detecting, and which may reduce quality and effectiveness of malaria treatment. Health service provider practices in prescribing and dosing anti-malarial drugs, due to drug stock-outs or high patient load, risk development of drug resistance, treatment failure and exposure to adverse effects.

  5. Final report of the radiological release survey of Building 11 at the Grand Junction Office Facility

    International Nuclear Information System (INIS)

    Johnson, R.K.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailings during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission's domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 11 and the underlying soil were found not to be radiologically contaminated; therefore, the building can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual final release report for each GJO building

  6. Final report of the radiological release survey of Building 29 at the Grand Junction Office Facility

    International Nuclear Information System (INIS)

    Johnson, R.K.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailing during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission's domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 29 and the underlying soil were found not to be radiologically contaminated; therefore, the building can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual final release report for each GJO building

  7. Final report of the radiological release survey of Building 19 at the Grand Junction Office Facility

    International Nuclear Information System (INIS)

    Johnson, R.K.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailings during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission's domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 19 and the underlying soil were found not to be radiologically contaminated; therefore, the building can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual final release report for each GJO building

  8. Final report of the radiological release survey of Building 54 at the Grand Junction Office Facility

    International Nuclear Information System (INIS)

    Johnson, R.K.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailings during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission's domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 54 and the underlying soil were found not to be radiologically contaminated, and can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual release report for each GJO building

  9. Radiological Assessment Survey of the Vance road Facility Source Vault Building Materials, Oak Ridge Institute for Science and Education, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    Morton, J. R.

    2000-01-01

    From the 1950s, the Vance Road laboratory was the site of extensive nuclear medical research and involved the used of numerous radionuclides. These nuclides were stored in a source vault stored on the first floor of the facility. Nuclear medical research is no longer conducted in this facility, and the source vault was remediated in preparation for converting the area to office space and general use. The Environmental Survey and Site Assessment Program (ESSAP) of ORISE performed a radiological assessment survey of the source vault and its associated miscellaneous building materials and laboratory equipment in preparation for the conversion to general use space

  10. Indexing contamination surveys

    International Nuclear Information System (INIS)

    Brown, R.L.

    1998-01-01

    The responsibility for safely managing the Tank Farms at Hanford belongs to Lockheed Martin Hanford Corporation which is part of the six company Project Hanford Management Team led by Fluor Daniel Hanford, Inc.. These Tank Farm Facilities contain numerous outdoor contamination areas which are surveyed at a periodicity consistent with the potential radiological conditions, occupancy, and risk of changes in radiological conditions. This document describes the survey documentation and data tracking method devised to track the results of contamination surveys this process is referred to as indexing. The indexing process takes a representative data set as an indicator for the contamination status of the facility. The data are further manipulated into a single value that can be tracked and trended using standard statistical methodology. To report meaningful data, the routine contamination surveys must be performed in a manner that allows the survey method and the data collection process to be recreated. Three key criteria are necessary to accomplish this goal: Accurate maps, consistent documentation, and consistent consolidation of data meeting these criteria provides data of sufficient quality to be tracked. Tracking of survey data is accomplished by converting the individual survey results into a weighted value, corrected for the actual number of survey points. This information can be compared over time using standard statistical analysis to identify trends. At the Tank Farms, the need to track and trend the facility's radiological status presents unique challenges. Many of these Tank Farm facilities date back to the second world war. The Tank Farm Facilities are exposed to weather extremes, plant and animal intrusion, as well as all of the normal challenges associated with handling radiological waste streams. Routine radiological surveys did not provide a radiological status adequate for continuing comparisons

  11. Post-remedial-action survey report for Kinetic Experiment Water Boiler Reactor Facility, Santa Susana Field Laboratories, Rockwell International, Ventura County, California

    International Nuclear Information System (INIS)

    Wynveen, R.A.; Smith, W.H.; Sholeen, C.M.; Flynn, K.F.; Justus, A.L.

    1981-10-01

    Rockwell International's Santa Susana Laboratories in Ventura County, California, have been the site of numerous federally-funded contracted projects involving the use of radioactive materials. Among these was the Kinetics Experiment Water Boiler (KEWB) Reactor which was operated under the auspices of the US Atomic Energy Commission (AEC). The KEWB Reactor was last operated in 1966. The facility was subsequently declared excess and decontamination and decommissioning operations were conducted during the first half of calendar year 1975. The facility was completely dismantled and the site graded to blend with the surrounding terrain. During October 1981, a post-remedial-action (certification) survey of the KEWB site was conducted on the behalf of the US Department of Energy by the Radiological Survey Group (RSG) of the Occupational Health and Safety Division's Health Physics Section (OHS/HP) of Argonne National Laboratory (ANL). The survey confirmed that the site was free from contamination and could be released for unrestricted use

  12. Patient-, health worker-, and health facility-level determinants of correct malaria case management at publicly funded health facilities in Malawi: results from a nationally representative health facility survey.

    Science.gov (United States)

    Steinhardt, Laura C; Chinkhumba, Jobiba; Wolkon, Adam; Luka, Madalitso; Luhanga, Misheck; Sande, John; Oyugi, Jessica; Ali, Doreen; Mathanga, Don; Skarbinski, Jacek

    2014-02-20

    Prompt and effective case management is needed to reduce malaria morbidity and mortality. However, malaria diagnosis and treatment is a multistep process that remains problematic in many settings, resulting in missed opportunities for effective treatment as well as overtreatment of patients without malaria. Prior to the widespread roll-out of malaria rapid diagnostic tests (RDTs) in late 2011, a national, cross-sectional, complex-sample, health facility survey was conducted in Malawi to assess patient-, health worker-, and health facility-level factors associated with malaria case management quality using multivariate Poisson regression models. Among the 2,019 patients surveyed, 34% had confirmed malaria defined as presence of fever and parasitaemia on a reference blood smear. Sixty-seven per cent of patients with confirmed malaria were correctly prescribed the first-line anti-malarial, with most cases of incorrect treatment due to missed diagnosis; 31% of patients without confirmed malaria were overtreated with an anti-malarial. More than one-quarter of patients were not assessed for fever or history of fever by health workers. The most important determinants of correct malaria case management were patient-level clinical symptoms, such as spontaneous complaint of fever to health workers, which increased both correct treatment and overtreatment by 72 and 210%, respectively (pfacility-level factors were significantly associated with case management quality. Introduction of RDTs holds potential to improve malaria case management in Malawi, but health workers must systematically assess all patients for fever, and then test and treat accordingly, otherwise, malaria control programmes might miss an opportunity to dramatically improve malaria case management, despite better diagnostic tools.

  13. Establishment and Operation of User Facilities

    International Nuclear Information System (INIS)

    Kim, Kye Ryung; Park, B. S.; Lim, Y. K.; Lee, S. K.; Jung, J. P.

    2005-08-01

    The final goal of this project is to establish the proton beam user facility which can offer the suitable proton beam for the user's demand. In the first phase we developed the key technologies that were required for the establishment of 20MeV and 100MeV proton user facilities. The user's demand survey was also achieved, and the test user facility was established on the results of the demand survey. Using the test facility, the users performed their pilot studies. Now, we have finished the conceptual design for 20MeV proton user facility. During the first phase we performed the user's demand survey and produced many materials related to the proton beam utilizations in domestic or abroad. The survey results were reflected on the establishment of the test user facility and the conceptual design of 20MeV/100MeV proton beam user facilities. We have developed the key technologies which concern to beam energy control, flux control, uniform irradiation, dose and uniformity measurement, proton energy measurement, SOBP(Spread-out Bragg Peak) system using a rotating range modulator, and carried out the conceptual design of 20MeV proton user facility. The test user facility has been constructed and operated for both verifying the developed key technologies and performing the user's preliminary experiments. 45MeV low flux user facility was constructed in 2003 and has performed a lot of irradiation experiments. The development of 1.8MeV test user facility was completed. Also the low energy user facility that KAERI kept was upgraded and used for many users. Therefore, we provided our users with various beams. On the other hand, the following activities were carried out, such as, inviting the oversea researchers, giving support to users to use the beam in domestic and abroad, discussing the beam utilization technologies by visiting the foreign user facilities, etc

  14. Medical facility statistics in Japan.

    Science.gov (United States)

    Hamajima, Nobuyuki; Sugimoto, Takuya; Hasebe, Ryo; Myat Cho, Su; Khaing, Moe; Kariya, Tetsuyoshi; Mon Saw, Yu; Yamamoto, Eiko

    2017-11-01

    Medical facility statistics provide essential information to policymakers, administrators, academics, and practitioners in the field of health services. In Japan, the Health Statistics Office of the Director-General for Statistics and Information Policy at the Ministry of Health, Labour and Welfare is generating these statistics. Although the statistics are widely available in both Japanese and English, the methodology described in the technical reports are primarily in Japanese, and are not fully described in English. This article aimed to describe these processes for readers in the English-speaking world. The Health Statistics Office routinely conduct two surveys called the Hospital Report and the Survey of Medical Institutions. The subjects of the former are all the hospitals and clinics with long-term care beds in Japan. It comprises a Patient Questionnaire focusing on the numbers of inpatients, admissions, discharges, and outpatients in one month, and an Employee Questionnaire, which asks about the number of employees as of October 1. The Survey of Medical Institutions consists of the Dynamic Survey, which focuses on the opening and closing of facilities every month, and the Static Survey, which focuses on staff, facilities, and services as of October 1, as well as the number of inpatients as of September 30 and the total number of outpatients during September. All hospitals, clinics, and dental clinics are requested to submit the Static Survey questionnaire every three years. These surveys are useful tools for collecting essential information, as well as providing occasions to implicitly inform facilities of the movements of government policy.

  15. Are nursing home survey deficiencies higher in facilities with greater staff turnover.

    Science.gov (United States)

    Lerner, Nancy B; Johantgen, Meg; Trinkoff, Alison M; Storr, Carla L; Han, Kihye

    2014-02-01

    To examine CNA and licensed nurse (RN+LPN/LVN) turnover in relation to numbers of deficiencies in nursing homes. A secondary data analysis of information from the National Nursing Home Survey (NNHS) and contemporaneous data from the Online Survey, Certification and Reporting (OSCAR) database. Data were linked by facility as the unit of analysis to determine the relationship of CNA and licensed nurse turnover on nursing home deficiencies. The 2004 NNHS used a multistage sampling strategy to generate a final sample of 1174 nursing homes, which represent 16,100 NHs in the United States. This study focused on the 1151 NNHS facilities with complete deficiency data. Turnover was defined as the total CNAs/licensed nurse full-time equivalents (FTEs) who left during the preceding 3 months (full- and part-time) divided by the total FTE. NHs with high turnover were defined as those with rates above the 75th percentile (25.3% for CNA turnover and 17.9% for licensed nurse turnover) versus all other facilities. This study used selected OSCAR deficiencies from the Quality of Care, Quality of Life, and Resident Behavior categories, which are considered to be more closely related to nursing care. We defined NHs with high deficiencies as those with numbers of deficiencies above the 75th percentile versus all others. Using SUDAAN PROC RLOGIST, we included NNHS sampling design effects and examined associations of CNA/licensed nurse turnover with NH deficiencies, adjusting for staffing, skill mix, bed size, and ownership in binomial logistic regression models. High CNA turnover was associated with high numbers of Quality of Care (OR 1.53, 95% CI 1.10-2.13), Resident Behavior (OR 1.42, 95% CI 1.03-1.97) and total selected deficiencies (OR 1.54, 95% CI 1.12-2.12). Licensed nurse turnover was significantly related to Quality of Care deficiencies (OR 2.06, 95% CI 1.50-2.82) and total selected deficiencies (OR 1.71, 95% CI 1.25-2.33). When both CNA turnover and licensed nurse turnover were

  16. Survey report 1998. Survey on actual condition of science parks and similar facilities in Asian countries; 1998 nendo chosa hokokusho. Asia shokoku chiiki ni okeru science park nado no jittai chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    Implemented at NEDO, on such technical development issues peculiar to developing nations as are difficult to solve by their research and development ability alone, has been a consistent research cooperation with countries in question, such as installation of plants and research facilities, joint research operation, and training of researchers, while Japanese technological skill and research and development know how are utilized, as the international cooperation projects. In this survey, an actual condition was investigated including potential of science parks and similar facilities in Asian countries (Thailand, Indonesia, Malaysia and India), for the purpose of unearthing the needs, seeds, etc., of the future international research cooperation projects. The parks and facilities selected for the survey are as follows. The Thai technology/science parks are the Thai Science Park and four other parks; the Indonesian technology parks are Bukit Indah Industrial City and eleven other parks; the major Malaysian technology parks are Technology Park Malaysia and fourteen other parks; the major Indian technology parks are Electronics City and fifteen other parks. (NEDO)

  17. Facilities Performance Indicators Report, 2008-09

    Science.gov (United States)

    Hills, Christina, Ed.

    2010-01-01

    This paper features another expanded Web-based Facilities Performance Indicators Report (FPI). The purpose of APPA's Facilities Performance Indicators is to provide a representative set of statistics about facilities in educational institutions. The 2008-09 iteration of the Web-based Facilities Performance Indicators Survey was posted and…

  18. Final report of the radiological release survey of Building 30B at the Grand Junction Office Facility

    International Nuclear Information System (INIS)

    Krauland, P.A.; Corle, S.G.

    1997-09-01

    The U.S. Department of Energy (DOE) Grand Junction Office (GJO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore concentrates and mill tailings during vanadium refining activities of the Manhattan Engineer District, and during sampling, assaying, pilot milling, storage, and brokerage activities conducted for the U.S. Atomic Energy Commission's domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJO Remedial Action Project (GJORAP) to clean up and restore the facility lands, improvements, and underlying aquifer. WASTREN-Grand Junction is the site contractor for the facility and the remedial action contractor for GJORAP. Building 30B and the underlying soil were found not to be radiologically contaminated; therefore, the building can be released for unrestricted use. Placards have been placed at the building entrances indicating the completion of the radiological release survey and prohibiting the introduction of any radioactive materials within the building without written approvals from the GJO Facilities Operations Manager. This document was prepared in response to a DOE-GJO request for an individual final release report for each GJO building

  19. Crew Factors in Flight Operations XII: A Survey of Sleep Quantity and Quality in On-Board Crew Rest Facilities

    Science.gov (United States)

    Rosekind, Mark R.; Gregory, Kevin B.; Co, Elizabeth L.; Miller, Donna L.; Dinges, David F.

    2000-01-01

    Many aircraft operated on long-haul commercial airline flights are equipped with on-board crew rest facilities, or bunks, to allow crewmembers to rest during the flight. The primary objectives of this study were to gather data on how the bunks were used, the quantity and quality of sleep obtained by flight crewmembers in the facilities, and the factors that affected their sleep. A retrospective survey comprising 54 questions of varied format addressed demographics, home sleep habits, and bunk sleep habits. Crewmembers from three airlines with long-haul fleets carrying augmented crews consisting of B747-100/200, B747-400, and MD-11 aircraft equipped with bunks returned a total of 1404 completed surveys (a 37% response rate). Crewmembers from the three carriers were comparable demographically, although one carrier had older, more experienced flight crewmembers. Each group, on average, rated themselves as "good" or "very good" sleepers at home, and all groups obtained about the same average amount of sleep each night. Most were able to sleep in the bunks, and about two thirds indicated that these rest opportunities benefited their subsequent flight deck alertness and performance. Comfort, environment, and physiology (e.g., being ready for sleep) were identified as factors that most promoted sleep. Factors cited as interfering with sleep included random noise, thoughts, heat, and the need to use the bathroom. These factors, in turn, suggest potential improvements to bunk facilities and their use. Ratings of the three aircraft types suggested differences among facilities. Bunks in the MD-11 were rated significantly better than either of the B747 types, and the B747-400 bunks received better ratings than did the older, B747-100/200 facilities.

  20. [Surveying a zoological facility through satellite-based geodesy].

    Science.gov (United States)

    Böer, M; Thien, W; Tölke, D

    2000-06-01

    In the course of a thesis submitted for a diploma degree within the Fachhochschule Oldenburg the Serengeti Safaripark was surveyed in autumn and winter 1996/97 laying in the planning foundations for the application for licences from the controlling authorities. Taking into consideration the special way of keeping animals in the Serengeti Safaripark (game ranching, spacious walk-through-facilities) the intention was to employ the outstanding satellite based geodesy. This technology relies on special aerials receiving signals from 24 satellites which circle around the globe. These data are being gathered and examined. This examination produces the exact position of this aerial in a system of coordinates which allows depicting this point on a map. This procedure was used stationary (from a strictly defined point) as well as in the movement (in a moving car). Additionally conventional procedures were used when the satellite based geodesy came to its limits. Finally a detailed map of the Serengeti Safaripark was created which shows the position and size of stables and enclosures as well as wood and water areas and the sectors of the leisure park. Furthermore the established areas of the enclosures together with an already existing animal databank have flown into an information system with the help of which the stock of animals can be managed enclosure-orientated.

  1. Fiscal 1997 survey report. Basic survey on trends of waste use type production facilities and waste fuel production facilities; 1997 nendo chosa hokokusho. Haikibutsu riyogata seizo shisetsu oyobi haikibutsu nenryo seizo shisetsu doko kiso chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    This survey was made to obtain the basic data for future spread and promotion of No.6 type (waste use type production facilities) and No.7 type (waste fuel production facilities) which were added to the objects having been subsidized since fiscal 1997 under `the environmental harmony type energy community project.` In the former, the kiln in the cement industry and the blast furnace in the steel industry can be extremely large places to receive waste plastic since the facilities are distributed in every area and the treatment capacity is large. However, the effective collection, transportation and sorting of large quantity of waste plastic, especially the problem of removal of vinyl chloride, is a big bottleneck. As to the use of waste plastic using gasification technology, there are no actual results on the commercial basis. That is, however, appropriate for treatment of the waste difficult in treatment, and can be expected of the usage in the chemical industry. In the latter, in the facilities using industrial waste raw materials as fuel, solidification and liquefaction are both operated on a commercial basis. In relation to the solidification and use as fuel of general waste, the treatment of combustion ash is preventing the expansion of use of waste in the industrial field because of a large quantity of chlorine included in the products. 92 refs., 54 figs., 35 tabs.

  2. An aerial radiological survey of the Babcock and Wilcox Nuclear Facilities and surrounding area, Lynchburg, Virginia

    International Nuclear Information System (INIS)

    Guss, P.P.

    1993-04-01

    An aerial radiological survey was conducted from July 18 through July 25, 1988, over a 41-square-kilometer (16-square-mile) area surrounding the Babcock and Wilcox nuclear facilities located near Lynchburg, Virginia. The survey was conducted at a nominal altitude of 61 meters (200 feet) with line spacings of 91 meters (300 feet). A contour map of the terrestrial gamma exposure rate extrapolated to 1 meter above ground level (AGL) was prepared and overlaid on an aerial photograph. The terrestrial exposure rates varied from 8 to 12 microroentgens per hour (μR/h). A search of the data for man-made radiation sources revealed the presence of three areas of high count rates in the survey area. Spectra accumulated over the main plant showed the presence of cobalt-60 ( 60 Co) and cesium-137 ( 137 Cs). A second area near the main plant indicated the presence of uranium-235 ( 235 U). Protactinium-234m ( 234m Pa) and 60 Co Were detected over a building to the east of the main plant. Soil samples and pressurized ion chamber measurements were obtained at four locations within the survey boundaries in support of the aerial data

  3. Liberia_WADC00004_OHDR_Health_Facilities2010

    Data.gov (United States)

    United Nations Cartographic Section — This data is based on the survey questionnaire, which are included in the table belowWhat county is this facility in?What is the facility name?Is this facility a...

  4. The Practice of Electroconvulsive Therapy in US Correctional Facilities: A Nationwide Survey.

    Science.gov (United States)

    Surya, Sandarsh; McCall, W Vaughn; Iltis, Ana S; Rosenquist, Peter B; Hogan, Elizabeth

    2015-09-01

    There are little data regarding the practice of electroconvulsive therapy (ECT) in correctional settings in the United States. A survey was conducted to study the current practice of ECT in US prisons. We hypothesize that ECT is underutilized in the correctional setting. We also review the ethical aspects of using ECT for the treatment of mental illness in the prison population. A 12-question survey via a Survey Monkey link was emailed to chiefs of psychiatry, or the equivalent, of each state's department of corrections. We examined the frequency of Likert-type responses, tabulated individual comments for qualitative review, and grouped for comparison. Email contacts for chiefs of psychiatry, or the equivalent, for the department of corrections in 45 states (90%) were obtained and a survey link was sent. Thirty-one (68.9%) of 45 responded to the survey. Respondent estimates of the number of inmates with mental illness in 31 prison systems varied from less than 500 to more than 4500. Of these 31, 12 (38.7%) had more than 4500 inmates with mental illness. Four systems reported the use of ECT within the last 5 years. Of those, one reported use in the last 1 to 6 months, and 3 reported use in the last 2 to 5 years. Of these 4 prison systems, all felt that they had up to 10 patients who would benefit if ECT continued to be offered or became available in the future. None of these systems provided ECT within the prison. The inmates were referred to a local state psychiatric facility, a university hospital, or other institutions. The reasons for not using ECT as reported by the respondents are grouped under subheadings of stigma, ethical concerns, logistical concerns, and others. Considering the high prevalence of mental illness in prisons, one might expect a high prevalence of ECT responsive mental illness and, hence, provision of ECT to some prisoners with mental illness. However, our survey suggests that the use of ECT in prisons in the United States is low. Stigma

  5. Baseline results of the first malaria indicator survey in Iran at the health facility level

    Directory of Open Access Journals (Sweden)

    Taghizadeh-Asl Rahim

    2011-10-01

    Full Text Available Abstract Background Malaria continues to be a global public health challenge, particularly in developing countries. Delivery of prompt and effective diagnosis and treatment of malaria cases, detection of malaria epidemics within one week of onset and control them in less than a month, regular disease monitoring and operational classification of malaria are among the major responsibilities of the national malaria programme. The study was conducted to determine these indicators at the different level of primary health care facilities in malaria-affected provinces of Iran Methods In this survey, data was collected from 223 health facilities including health centres, malaria posts, health houses and hospitals as well as the profile of all 5, 836 recorded malaria cases in these facilities during the year preceding the survey. Descriptive statistics (i.e. frequencies, percentages were used to summarize the results and Chi square test was used to analyse data. Results All but one percent of uncomplicated cases took appropriate and correctly-dosed of anti-malarial drugs in accordance to the national treatment guideline. A larger proportion of patients [85.8%; 95% CI: 84.8 - 86.8] were also given complete treatment including anti-relapse course, in line with national guidelines. About one third [35.0%; 95% CI: 33.6 - 36.4] of uncomplicated malaria cases were treated more than 48 hours after first symptoms onset. Correspondingly, half of severe malaria cases took recommended anti-malarial drugs for severe or complicated disease more than 48 hours of onset of first symptoms. The latter cases had given regular anti-malarial drugs promptly. The majority of malaria epidemics [97%; 95% CI: 90.6 - 100] in study areas were detected within one week of onset, but only half of epidemics were controlled within four weeks of detection. Just half of target districts had at least one health facility/emergency site with adequate supply and equipment stocks. Nevertheless

  6. Results of Surveys for Special Status Reptiles at the Site 300 Facilities of Lawrence Livermore National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Woollett, J J

    2008-09-18

    The purpose of this report is to present the results of a live-trapping and visual surveys for special status reptiles at the Site 300 Facilities of Lawrence Livermore National Laboratory (LLNL). The survey was conducted under the authority of the Federal recovery permit of Swaim Biological Consulting (PRT-815537) and a Memorandum of Understanding issued from the California Department of Fish and Game. Site 300 is located between Livermore and Tracy just north of Tesla road (Alameda County) and Corral Hollow Road (San Joaquin County) and straddles the Alameda and San Joaquin County line (Figures 1 and 2). It encompasses portions of the USGS 7.5 minute Midway and Tracy quadrangles (Figure 2). Focused surveys were conducted for four special status reptiles including the Alameda whipsnake (Masticophis lateralis euryxanthus), the San Joaquin Whipsnake (Masticophis Hagellum ruddock), the silvery legless lizard (Anniella pulchra pulchra), and the California horned lizard (Phrynosoma coronanum frontale).

  7. Quality of antenatal care service provision in health facilities across sub-Saharan Africa: Evidence from nationally representative health facility assessments.

    Science.gov (United States)

    Kanyangarara, Mufaro; Munos, Melinda K; Walker, Neff

    2017-12-01

    Utilization of antenatal care (ANC) services has increased over the past two decades. Continued gains in maternal and newborn health will require an understanding of both access and quality of ANC services. We linked health facility and household survey data to examine the quality of service provision for five ANC interventions across health facilities in sub-Saharan Africa. Using data from 20 nationally representative health facility assessments - the Service Provision Assessment (SPA) and the Service Availability and Readiness Assessment (SARA), we estimated facility level readiness to deliver five ANC interventions: tetanus toxoid vaccine for pregnant women, intermittent preventive treatment for malaria in pregnancy (IPTp), syphilis detection and treatment in pregnancy, iron supplementation and hypertensive disease case management. Facility level indicators were stratified by health facility type, managing authority and location, then linked to estimates of ANC utilization in that stratum from the corresponding Demographic and Health Surveys (DHS) to generate population level estimates of the 'likelihood of appropriate care'. Finally, the association between estimates of the 'likelihood of appropriate care' from the linking approach and estimates of coverage levels from the DHS were assessed. A total of 10 534 health facilities were surveyed in the 20 health facility assessments, of which 8742 reported offering ANC services and were included in the analysis. Health facility readiness to deliver IPTp, iron supplementation, and tetanus toxoid vaccination was higher (median: 84.1%, 84.9% and 82.8% respectively) than readiness to deliver hypertensive disease case management and syphilis detection and treatment (median: 23.0% and 19.9% respectively). Coverage of at least 4 ANC visits ranged from 24.8% to 75.8%. Estimates of the likelihood of appropriate care derived from linking health facility and household survey data showed marked gaps for all interventions

  8. The environmental survey manual

    International Nuclear Information System (INIS)

    1987-08-01

    The purpose of this manual is to provide guidance to the Survey and Sampling and Analysis teams that conduct the one-time Environmental Survey of the major US Department of Energy (DOE) operating facilities. This manual includes a discussion of DOE's policy on environmental issues, a review of statutory guidance as it applies to the Survey, the procedures and protocols to be used by the Survey teams, criteria for the use of the Survey teams in evaluating existing environmental data for the Survey effort, generic technical checklists used in every Survey, health and safety guidelines for the personnel conducting the Survey, including the identification of potential hazards, prescribed protective equipment, and emergency procedures, the required formats for the Survey reports, guidance on identifying environmental problems that need immediate attention by the Operations Office responsible for the particular facility, and procedures and protocols for the conduct of sampling and analysis

  9. Environmental Survey preliminary report, Idaho National Engineering Laboratory, Idaho Falls, Idaho and Component Development and Integration Facility, Butte, Montana

    International Nuclear Information System (INIS)

    1988-09-01

    This report presents the preliminary findings of the first phase of the Environmental Survey of the United States Department of Energy's (DOE) Idaho National Engineering Laboratory (INEL) and Component Development and Integration Facility (CDIF), conducted September 14 through October 2, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. The team includes outside experts supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with the INEL and CDIF. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. The on-site phase of the Survey involves the review of existing site environmental data, observations of the operations' carried on at the INEL and the CDIF, and interviews with site personnel. The Survey team developed a Sampling and Analysis (S ampersand A) Plan to assist in further assessing certain of the environmental problems identified during its on-site activities. The S ampersand A Plan will be executed by the Oak Ridge National Laboratory. When completed, the S ampersand A results will be incorporated into the INEL/CDIF Survey findings for inclusion into the Environmental Survey Summary Report. 90 refs., 95 figs., 77 tabs

  10. Environmental Survey preliminary report, Idaho National Engineering Laboratory, Idaho Falls, Idaho and Component Development and Integration Facility, Butte, Montana

    Energy Technology Data Exchange (ETDEWEB)

    1988-09-01

    This report presents the preliminary findings of the first phase of the Environmental Survey of the United States Department of Energy's (DOE) Idaho National Engineering Laboratory (INEL) and Component Development and Integration Facility (CDIF), conducted September 14 through October 2, 1987. The Survey is being conducted by an interdisciplinary team of environmental specialists, led and managed by the Office of Environment, Safety and Health's Office of Environmental Audit. The team includes outside experts supplied by a private contractor. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with the INEL and CDIF. The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. The on-site phase of the Survey involves the review of existing site environmental data, observations of the operations' carried on at the INEL and the CDIF, and interviews with site personnel. The Survey team developed a Sampling and Analysis (S A) Plan to assist in further assessing certain of the environmental problems identified during its on-site activities. The S A Plan will be executed by the Oak Ridge National Laboratory. When completed, the S A results will be incorporated into the INEL/CDIF Survey findings for inclusion into the Environmental Survey Summary Report. 90 refs., 95 figs., 77 tabs.

  11. Signal functions for emergency obstetric care as an intervention for reducing maternal mortality: a survey of public and private health facilities in Lusaka District, Zambia.

    Science.gov (United States)

    Tembo, Tannia; Chongwe, Gershom; Vwalika, Bellington; Sitali, Lungowe

    2017-09-06

    Zambia's maternal mortality ratio was estimated at 398/100,000 live births in 2014. Successful aversion of deaths is dependent on availability and usability of signal functions for emergency obstetric and neonatal care. Evidence of availability, usability and quality of signal functions in urban settings in Zambia is minimal as previous research has evaluated their distribution in rural settings. This survey evaluated the availability and usability of signal functions in private and public health facilities in Lusaka District of Zambia. A descriptive cross sectional study was conducted between November 2014 and February 2015 at 35 public and private health facilities. The Service Availability and Readiness Assessment tool was adapted and administered to overall in-charges, hospital administrators or maternity ward supervisors at health facilities providing maternal and newborn health services. The survey quantified infrastructure, human resources, equipment, essential drugs and supplies and used the UN process indicators to determine availability, accessibility and quality of signal functions. Data on deliveries and complications were collected from registers for periods between June 2013 and May 2014. Of the 35 (25.7% private and 74.2% public) health facilities assessed, only 22 (62.8%) were staffed 24 h a day, 7 days a week and had provided obstetric care 3 months prior to the survey. Pre-eclampsia/ eclampsia and obstructed labor accounted for most direct complications while postpartum hemorrhage was the leading cause of maternal deaths. Overall, 3 (8.6%) and 5 (14.3%) of the health facilities had provided Basic and Comprehensive EmONC services, respectively. All facilities obtained blood products from the only blood bank at a government referral hospital. The UN process indicators can be adequately used to monitor progress towards maternal mortality reduction. Lusaka district had an unmet need for BEmONC as health facilities fell below the minimum UN standard

  12. Understanding the relationship between access to care and facility-based delivery through analysis of the 2008 Ghana Demographic Health Survey.

    Science.gov (United States)

    Moyer, Cheryl A; McLaren, Zoë M; Adanu, Richard M; Lantz, Paula M

    2013-09-01

    To determine the types of access to care most strongly associated with facility-based delivery among women in Ghana. Data relating to the "5 As of Access" framework were extracted from the 2008 Ghana Demographic Health Survey and analyzed using multivariate logistic regression. In all, 55.5% of a weighted sample of 1102 women delivered in a healthcare facility, whereas 45.5% delivered at home. Affordability was the strongest access factor associated with delivery location, with health insurance coverage tripling the odds of facility delivery. Availability, accessibility (except urban residence), acceptability, and social access variables were not significant factors in the final models. Social access variables, including needing permission to seek healthcare and not being involved in decisions regarding healthcare, were associated with a reduced likelihood of facility-based delivery when examined individually. Multivariate analysis suggested that these variables reflected maternal literacy, health insurance coverage, and household wealth, all of which attenuated the effects of social access. Affordability was an important determinant of facility delivery in Ghana-even among women with health insurance-but social access variables had a mediating role. Copyright © 2013 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  13. Final Status Survey Report for Corrective Action Unit 117 - Pluto Disassembly Facility, Building 2201, Nevada National Security Site, Nevada

    International Nuclear Information System (INIS)

    Gwin, Jeremy; Frenette, Douglas

    2010-01-01

    This document contains the process knowledge, radiological data and subsequent statistical methodology and analysis to support approval for the radiological release of Corrective Action Unit (CAU) 117 - Pluto Disassembly Facility, Building 2201 located in Area 26 of the Nevada National Security Site (NNSS). Preparations for release of the building began in 2009 and followed the methodology described in the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM). MARSSIM is the DOE approved process for release of Real Property (buildings and landmasses) to a set of established criteria or authorized limits. The pre-approved authorized limits for surface contamination values and corresponding assumptions were established by DOE O 5400.5. The release criteria coincide with the acceptance criteria of the U10C landfill permit. The U10C landfill is the proposed location to dispose of the radiologically non-impacted, or ''clean,'' building rubble following demolition. However, other disposition options that include the building and/or waste remaining at the NNSS may be considered providing that the same release limits apply. The Final Status Survey was designed following MARSSIM guidance by reviewing historical documentation and radiological survey data. Following this review a formal radiological characterization survey was performed in two phases. The characterization revealed multiple areas of residual radioactivity above the release criteria. These locations were remediated (decontaminated) and then the surface activity was verified to be less than the release criteria. Once remediation efforts had been successfully completed, a Final Status Survey Plan (10-015, ''Final Status Survey Plan for Corrective Action Unit 117 - Pluto Disassembly Facility, Building 2201'') was developed and implemented to complete the final step in the MARSSIM process, the Final Status Survey. The Final Status Survey Plan consisted of categorizing each individual room into one

  14. Survey report for fiscal 1999. Report on basic survey on joint implementation of installing coal moisture control (CMC) facilities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    For the purpose of the COP3 joint implementation in fiscal 1999, a survey and discussions were given on installing coal moisture control (CMC) facilities in China. The possibility was discussed with the Jinan Steel Group Company and Shougang Company. The subject is a beehive coke furnace, in which coal containing 11% of water is sent to a fluidized bed dryer, and dried up to 6.6%. Stack gas in the coke furnace is used mainly as the drying heat source. The facility consists of a fluidized bed dryer, a dust collector, a coal transporter, and a stack gas recovering device. The energy saving effects made available to the above two companies are as remarkable as 19,868 tons/year and 12,189 tons/year, respectively, as converted to crude oil, and the greenhouse effect gas reduction effect as 61,476 tons/year and 37,715 tons/year, respectively. Because energy price is low in China, the investment recovery time period is set at six years or less as the limit for economic performance evaluation. As a result of the calculation, the recovery time periods for the above two companies were found to be 4.2 and 4.7 years, proving the CMC project highly promising. It is desired that the project will be moved forward once the issues of the fund raising and the discharge right of global warming gas are made clear. (NEDO)

  15. Effect of maternal age on facility-based delivery: analysis of first-order births in 34 countries of sub-Saharan Africa using demographic and health survey data.

    Science.gov (United States)

    Dunlop, Catherine L; Benova, Lenka; Campbell, Oona

    2018-04-13

    Increasing access to skilled birth attendance, usually via childbirth in health facilities, is a key intervention to reduce maternal and perinatal mortality and morbidity. Yet, in some countries of sub-Saharan Africa, the uptake is Health Surveys from 34 sub-Saharan African countries were used to assess women's delivery locations. 72 772 women having their first birth in the 5 years preceding the surveys were included in the analysis. Proportions and 95% CIs of facility-based deliveries were estimated overall and by country. Multivariable logistic regression was used to calculate the odds of facility-based delivery for different maternal age groups (15-19, 20-24 and ≥25 years) for a pooled sample of all countries. 59.9% of women had a facility-based delivery for their first birth (95% CI 58.6 to 61.2), ranging from 19.4% in Chad to 96.6% in Rwanda. Compared with women aged 15-19 years, the adjusted odds of having a facility-based delivery for those aged 20-24 was 1.4 (95% CI 1.3 to 1.5, psub-Saharan Africa. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Results of the independent radiological verification survey at the former Bridgeport Brass Company Facility, Seymour, Connecticut (SSC001)

    International Nuclear Information System (INIS)

    Foley, R.D.; Rice, D.E.; Allred, J.F.; Brown, K.S.

    1995-03-01

    At the request of the USDOE, a team from ORNL conducted an independent radiological verification survey at the former Bridgeport Brass Company Facility, Seymour, Connecticut, from September 1992 to March 1993. Purpose of the survey was to determine whether residual levels of radioactivity inside the Ruffert Building and selected adjacent areas were rmediated to levels below DOE guidelines for FUSRAP sites. The property was contaminated with radioactive residues of 238 U from uranium processing experiments conducted by Reactive Metals, Inc., from 1962 to 1964 for the Atomic Energy Commission. A previous radiological survey did not characterize the entire floor space because equipment which could not be moved at the time made it inaccessible for radiological surveys. During the remediation process, additional areas of elevated radioactivity were discovered under stationary equipment, which required additional remediation and further verification. Results of the independent radiological verification survey confirm that, with the exception of the drain system inside the building, residual uranium contamination has been remediated to levels below DOE guidelines for unrestricted release of property at FUSRAP sites inside and outside the Ruffert Building. However, certain sections of the drain system retain uranium contamination above DOE surface guideline levels. These sections of pipe are addressed in separate, referenced documentation

  17. High electronegativity multi-dipolar electron cyclotron resonance plasma source for etching by negative ions

    DEFF Research Database (Denmark)

    Stamate, Eugen; Draghici, M.

    2012-01-01

    A large area plasma source based on 12 multi-dipolar ECR plasma cells arranged in a 3 x 4 matrix configuration was built and optimized for silicon etching by negative ions. The density ratio of negative ions to electrons has exceeded 300 in Ar/SF6 gas mixture when a magnetic filter was used...... to reduce the electron temperature to about 1.2 eV. Mass spectrometry and electrostatic probe were used for plasma diagnostics. The new source is free of density jumps and instabilities and shows a very good stability for plasma potential, and the dominant negative ion species is F-. The magnetic field...... in plasma volume is negligible and there is no contamination by filaments. The etching rate by negative ions measured in Ar/SF6/O-2 mixtures was almost similar with that by positive ions reaching 700 nm/min. (C) 2012 American Institute of Physics...

  18. Review of emergency obstetric care interventions in health facilities in the Upper East Region of Ghana: a questionnaire survey.

    Science.gov (United States)

    Kyei-Onanjiri, Minerva; Carolan-Olah, Mary; Awoonor-Williams, John Koku; McCann, Terence V

    2018-03-15

    Maternal morbidity and mortality is most prevalent in resource-poor settings such as sub-Saharan Africa and southern Asia. In sub-Saharan Africa, Ghana is one of the countries still facing particular challenges in reducing its maternal morbidity and mortality. Access to emergency obstetric care (EmOC) interventions has been identified as a means of improving maternal health outcomes. Assessing the range of interventions provided in health facilities is, therefore, important in determining capacity to treat obstetric emergencies. The aim of this study was to examine the availability of emergency obstetric care interventions in the Upper East Region of Ghana. A cross-sectional survey of 120 health facilities was undertaken. Status of emergency obstetric care was assessed through an interviewer administered questionnaire to directors/in-charge officers of maternity care units in selected facilities. Data were analysed using descriptive statistics. Eighty per cent of health facilities did not meet the criteria for provision of emergency obstetric care. Comparatively, private health facilities generally provided EmOC interventions less frequently than public health facilities. Other challenges identified include inadequate skill mix of maternity health personnel, poor referral processes, a lack of reliable communication systems and poor emergency transport systems. Multiple factors combine to limit women's access to a range of essential maternal health services. The availability of EmOC interventions was found to be low across the region; however, EmOC facilities could be increased by nearly one-third through modest investments in some existing facilities. Also, the key challenges identified in this study can be improved by enhancing pre-existing health system structures such as Community-based Health Planning and Services (CHPS), training more midwifery personnel, strengthening in-service training and implementation of referral audits as part of health service

  19. A survey of strippable and tie-down coatings for use in the decommissioning of alpha-active facilities

    International Nuclear Information System (INIS)

    Turner, A.D.; Worrall, G.; Dalton, J.T.

    1987-04-01

    The paper concerns temporary coatings for use in decommissioning operations of alpha-active facilities. The various temporary coating options are described with respect to: decontamination by removal of a previously applied protective coating, and the in-situ application of a coating for tie-down or decontamination duties. The specifications for coating systems to be used in active areas are defined in general terms. A survey of currently available temporary coating material is given, as well as the suitability of commercially available coating systems. (U.K.)

  20. Facility management and energy efficiency -- analysis and recommendations; Facility Management und Energieeffizienz: Analyse und Handlungsempfehlungen

    Energy Technology Data Exchange (ETDEWEB)

    Staub, P.; Weibel, K.; Zaugg, T. [Pom and Consulting Ltd., Zuerich (Switzerland); Lang, R. [Gruenberg and Partner Ltd., Zuerich (Switzerland); Frei, Ch. [Herzog Kull Group, Aarau (Switzerland)

    2001-07-01

    This final report presents the results of a study made on how facility management (FM) is positioned in enterprises and on how energy management can be integrated into the facility management process. Also, recommendations are made on the actions that are considered necessary to improve the understanding of facility management and energy management. The findings of an analysis made of the results of a survey among 200 enterprises, 20 interviews and 5 case studies are presented. The authors state that, in spite of the relatively small sample taken - mostly larger enterprises - trends in facility management and energy management could be shown. The findings of the survey, such as the relative importance of the integration of energy topics in facility management and the need for standardised indicators and benchmarking, are discussed in detail. Also, it is noted that the success of FM is in part due to delegation of responsibility to smaller business units or even to individual employees. The market potential for FM services is examined, with yearly growth rates of up to 20%. The importance of anchoring FM strategies at the top level of management is stressed, as is the need for promotion of the idea of facility management and training concepts for those responsible for its implementation.

  1. A Global Survey of Deep Underground Facilities; Examples of Geotechnical and Engineering Capabilities, Achievements, Challenges (Mines, Shafts, Tunnels, Boreholes, Sites and Underground Facilities for Nuclear Waste and Physics R&D): A Guide to Interactive Global Map Layers, Table Database, References and Notes

    International Nuclear Information System (INIS)

    Tynan, Mark C.; Russell, Glenn P.; Perry, Frank V.; Kelley, Richard E.; Champenois, Sean T.

    2017-01-01

    These associated tables, references, notes, and report present a synthesis of some notable geotechnical and engineering information used to create four interactive layer maps for selected: 1) deep mines and shafts; 2) existing, considered or planned radioactive waste management deep underground studies or disposal facilities 3) deep large diameter boreholes, and 4) physics underground laboratories and facilities from around the world. These data are intended to facilitate user access to basic information and references regarding “deep underground” facilities, history, activities, and plans. In general, the interactive maps and database provide each facility’s approximate site location, geology, and engineered features (e.g.: access, geometry, depth, diameter, year of operations, groundwater, lithology, host unit name and age, basin; operator, management organization, geographic data, nearby cultural features, other). Although the survey is not comprehensive, it is representative of many of the significant existing and historical underground facilities discussed in the literature addressing radioactive waste management and deep mined geologic disposal safety systems. The global survey is intended to support and to inform: 1) interested parties and decision makers; 2) radioactive waste disposal and siting option evaluations, and 3) safety case development applicable to any mined geologic disposal facility as a demonstration of historical and current engineering and geotechnical capabilities available for use in deep underground facility siting, planning, construction, operations and monitoring.

  2. A Global Survey of Deep Underground Facilities; Examples of Geotechnical and Engineering Capabilities, Achievements, Challenges (Mines, Shafts, Tunnels, Boreholes, Sites and Underground Facilities for Nuclear Waste and Physics R&D): A Guide to Interactive Global Map Layers, Table Database, References and Notes

    Energy Technology Data Exchange (ETDEWEB)

    Tynan, Mark C. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Russell, Glenn P. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Perry, Frank V. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Kelley, Richard E. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Champenois, Sean T. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-06-13

    These associated tables, references, notes, and report present a synthesis of some notable geotechnical and engineering information used to create four interactive layer maps for selected: 1) deep mines and shafts; 2) existing, considered or planned radioactive waste management deep underground studies or disposal facilities 3) deep large diameter boreholes, and 4) physics underground laboratories and facilities from around the world. These data are intended to facilitate user access to basic information and references regarding “deep underground” facilities, history, activities, and plans. In general, the interactive maps and database provide each facility’s approximate site location, geology, and engineered features (e.g.: access, geometry, depth, diameter, year of operations, groundwater, lithology, host unit name and age, basin; operator, management organization, geographic data, nearby cultural features, other). Although the survey is not comprehensive, it is representative of many of the significant existing and historical underground facilities discussed in the literature addressing radioactive waste management and deep mined geologic disposal safety systems. The global survey is intended to support and to inform: 1) interested parties and decision makers; 2) radioactive waste disposal and siting option evaluations, and 3) safety case development applicable to any mined geologic disposal facility as a demonstration of historical and current engineering and geotechnical capabilities available for use in deep underground facility siting, planning, construction, operations and monitoring.

  3. Facilities Performance Indicators Report, 2006-07

    Science.gov (United States)

    Glazner, Steve, Ed.

    2008-01-01

    The "Facilities Performance Indicators Survey" ("FPI") supersedes and builds upon the two major surveys APPA conducted in the past: the Comparative Costs and Staffing (CCAS) survey and the Strategic Assessment Model (SAM). The "FPI" covers all the materials collected in CCAS and SAM, along with some select new data points and improved survey…

  4. NIMBY, CLAMP, and the location of new nuclear-related facilities: U.S. national and 11 site-specific surveys.

    Science.gov (United States)

    Greenberg, Michael R

    2009-09-01

    Public and political opposition have made finding locations for new nuclear power plants, waste management, and nuclear research and development facilities a challenge for the U.S. government and the nuclear industry. U.S. government-owned properties that already have nuclear-related activities and commercial nuclear power generating stations are logical locations. Several studies and utility applications to the Nuclear Regulatory Commission suggest that concentrating locations at major plants (CLAMP) has become an implicit siting policy. We surveyed 2,101 people who lived within 50 miles of 11 existing major nuclear sites and 600 who lived elsewhere in the United States. Thirty-four percent favored CLAMP for new nuclear power plants, 52% for waste management facilities, and 50% for new nuclear laboratories. College educated, relatively affluent male whites were the strongest CLAMP supporters. They disproportionately trusted those responsible for the facilities and were not worried about existing nuclear facilities or other local environmental issues. Notably, they were concerned about continuing coal use. Not surprisingly, CLAMP proponents tended to be familiar with their existing local nuclear site. In short, likely CLAMP sites have a large and politically powerful core group to support a CLAMP policy. The challenge to proponents of nuclear technologies will be to sustain this support and expand the base among those who clearly are less connected and receptive to new nearby sites.

  5. Decommissioning of a Radioactive Facility Used for Biomolecule Labeling and Biological Effects

    International Nuclear Information System (INIS)

    Yagüe, L.; Navarro, N.; Álvarez, A.; Quiñones, J.

    2015-01-01

    This paper presents the measurement methodology designed for the final status survey of an old radioactive facility, used as radiolabeling lab. Its declassification as radioactive facility required the radiological characterization of all walls, structures and materials at the facility in order to reuse its outbuilding for conventional use. To demonstrate compliance with the declassification criteria, the design of the final status survey was performed applying MARSSIM(1) (Multi-Agency Radiation Survey and Site Investigation Manual) methodology and using different measurement techniques depending on the radioactive isotopes in the inventory of the facility, their half-lives and emission characteristics.

  6. Fuel Processing Plants - ETHANOL_PRODUCTION_FACILITIES_IN: Ethanol Production Facilities in Indiana (Indiana Geological Survey, Point Shapefile)

    Data.gov (United States)

    NSGIC State | GIS Inventory — This GIS layer shows the locations of ethanol production facilities in the state of Indiana. Attributes include the name and address of the facility, and information...

  7. Sanford Underground Research Facility - The United State's Deep Underground Research Facility

    Science.gov (United States)

    Vardiman, D.

    2012-12-01

    /LIDAR), surveying instruments, and surveying benchmarks and optical survey points. Currently an array of single and multipoint extensometers monitors the Davis Campus. A facility-wide micro seismic monitoring system is anticipated to be deployed during the latter half of 2012. This system is designed to monitor minor events initiated within the historical mined out portions of the facility. The major science programs for the coming five years consist of the MAJORANA DEMONSTRATOR (MJD) neutrinoless double beta decay experiment; the Large Underground Xenon (LUX) dark matter search, the Center for Ultralow Background Experiments at DUSEL (CUBED), numerous geoscience installations, Long-Baseline Neutrino Experiment (LBNE), a nuclear astrophysics program involving a low energy underground particle accelerator, second and third generation dark matter experiments, and additional low background counting facilities. The Sanford Lab facility is an active, U.S. based, deep underground research facility dedicated to science, affording the science community the opportunity to conduct unprecedented scientific research in a broad range of physics, biology and geoscience fields at depth. SURF is actively interested in hosting additional research collaborations and provides resources for full facility design, cost estimation, excavation, construction and support management services.

  8. Are Health Facility Management Committees in Kenya ready to implement financial management tasks: findings from a nationally representative survey.

    Science.gov (United States)

    Waweru, Evelyn; Opwora, Antony; Toda, Mitsuru; Fegan, Greg; Edwards, Tansy; Goodman, Catherine; Molyneux, Sassy

    2013-10-10

    Community participation in peripheral public health facilities has in many countries focused on including community representatives in Health Facility Management Committees (HFMCs). In Kenya, HFMC roles are being expanded with the phased implementation of the Health Sector Services Fund (HSSF). Under HSSF, HFMCs manage facility funds which are dispersed directly from central level into facility bank accounts. We assessed how prepared HFMCs were to undertake this new role in advance of HSSF roll out, and considered the implications for Kenya and other similar settings. Data were collected through a nationally representative sample of 248 public health centres and dispensaries in 24 districts in 2010. Data collection included surveys with in-charges (n = 248), HFMC members (n = 464) and facility users (n = 698), and record reviews. These data were supplemented by semi-structured interviews with district health managers in each district. Some findings supported preparedness of HFMCs to take on their new roles. Most facilities had bank accounts and HFMCs which met regularly. HFMC members and in-charges generally reported positive relationships, and HFMC members expressed high levels of motivation and job satisfaction. Challenges included users' low awareness of HFMCs, lack of training and clarity in roles among HFMCs, and some indications of strained relations with in-charges. Such challenges are likely to be common to many similar settings, and are therefore important considerations for any health facility based initiatives involving HFMCs. Most HFMCs have the basic requirements to operate. However to manage their own budgets effectively and meet their allocated roles in HSSF implementation, greater emphasis is needed on financial management training, targeted supportive supervision, and greater community awareness and participation. Once new budget management roles are fully established, qualitative and quantitative research on how HFMCs are adapting to

  9. DUPIC facility engineering

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J S; Choi, J W; Go, W I; Kim, H D; Song, K C; Jeong, I H; Park, H S; Im, C S; Lee, H M; Moon, K H; Hong, K P; Lee, K S; Suh, K S; Kim, E K; Min, D K; Lee, J C; Chun, Y B; Paik, S Y; Lee, E P; Yoo, G S; Kim, Y S; Park, J C

    1997-09-01

    In the early stage of the project, a comprehensive survey was conducted to identify the feasibility of using available facilities and of interface between those facilities. It was found out that the shielded cell M6 interface between those facilities. It was found out that the shielded cell M6 of IMEF could be used for the main process experiments of DUPIC fuel fabrication in regard to space adequacy, material flow, equipment layout, etc. Based on such examination, a suitable adapter system for material transfer around the M6 cell was engineered. Regarding the PIEF facility, where spent PWR fuel assemblies are stored in an annex pool, disassembly devices in the pool are retrofitted and spent fuel rod cutting and shipping system to the IMEF are designed and built. For acquisition of casks for radioactive material transport between the facilities, some adaptive refurbishment was applied to the available cask (Padirac) based on extensive analysis on safety requirements. A mockup test facility was newly acquired for remote test of DUPIC fuel fabrication process equipment prior to installation in the M6 cell of the IMEF facility. (author). 157 refs., 57 tabs., 65 figs.

  10. DUPIC facility engineering

    International Nuclear Information System (INIS)

    Lee, J. S.; Choi, J. W.; Go, W. I.; Kim, H. D.; Song, K. C.; Jeong, I. H.; Park, H. S.; Im, C. S.; Lee, H. M.; Moon, K. H.; Hong, K. P.; Lee, K. S.; Suh, K. S.; Kim, E. K.; Min, D. K.; Lee, J. C.; Chun, Y. B.; Paik, S. Y.; Lee, E. P.; Yoo, G. S.; Kim, Y. S.; Park, J. C.

    1997-09-01

    In the early stage of the project, a comprehensive survey was conducted to identify the feasibility of using available facilities and of interface between those facilities. It was found out that the shielded cell M6 interface between those facilities. It was found out that the shielded cell M6 of IMEF could be used for the main process experiments of DUPIC fuel fabrication in regard to space adequacy, material flow, equipment layout, etc. Based on such examination, a suitable adapter system for material transfer around the M6 cell was engineered. Regarding the PIEF facility, where spent PWR fuel assemblies are stored in an annex pool, disassembly devices in the pool are retrofitted and spent fuel rod cutting and shipping system to the IMEF are designed and built. For acquisition of casks for radioactive material transport between the facilities, some adaptive refurbishment was applied to the available cask (Padirac) based on extensive analysis on safety requirements. A mockup test facility was newly acquired for remote test of DUPIC fuel fabrication process equipment prior to installation in the M6 cell of the IMEF facility. (author). 157 refs., 57 tabs., 65 figs

  11. Cultural-resource survey report: Hoover Dam Powerplant Modification Project II. Associated transmission-line facility

    International Nuclear Information System (INIS)

    Queen, R.L.

    1991-06-01

    The Bureau of Reclamation (Reclamation) is proposing to modify or install additional transmission facilities between the Hoover Dam hydroelectric plant and the Western Area Power Authority substation near Boulder City, Nevada. Reclamation has completed cultural resource investigations to identify historic or prehistoric resources in the project area that might be affected during construction of the transmission line. Four possible transmission corridors approximately 50 feet wide and between 9.5 and 11.5 miles long were investigated. The proposed transmission lines either parallel or replace existing transmission lines. The corridors generally have undergone significant disturbance from past transmission line construction. A Class II sampling survey covering approximately 242 acres was conducted. Access or construction roads have not been identified and surveys of these areas will have to be completed in the future. No historic or prehistoric archeological sites were encountered within the four corridor right-of-ways. It is believed that the probability for prehistoric sites is very low. Four historic period sites were recorded that are outside, but near, the proposed corridor. These sites are not individually eligible for the National Register of Historic Places, but may be associated with the construction of Hoover Dam and contribute to a historic district or multiple property resource area focusing on the dam and its construction

  12. Academic Computing Facilities and Services in Higher Education--A Survey.

    Science.gov (United States)

    Warlick, Charles H.

    1986-01-01

    Presents statistics about academic computing facilities based on data collected over the past six years from 1,753 institutions in the United States, Canada, Mexico, and Puerto Rico for the "Directory of Computing Facilities in Higher Education." Organizational, functional, and financial characteristics are examined as well as types of…

  13. Iowa Intensive Archaeological Survey

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — This shape file contains intensive level archaeological survey areas for the state of Iowa. All intensive Phase I surveys that are submitted to the State Historic...

  14. Microbiological monitoring of guinea pigs reared conventionally at two breeding facilities in Korea.

    Science.gov (United States)

    Park, Jong-Hwan; Seok, Seung-Hyeok; Baek, Min-Won; Lee, Hui-Young; Kim, Dong-Jae; Cho, Jung-Sik; Kim, Chuel-Kyu; Hwang, Dae-Youn; Park, Jae-Hak

    2006-10-01

    In this study, microbiological monitoring of guinea pigs reared conventionally in two facilities was performed twice in 2004, with a three-month-interval between surveys. This study was based on the recommendations of the FELASA Working Group, with some modifications. In serological tests in the first survey, some animals from facility A showed positive results for Encephalitozoon cuniculi, Sendai virus, pneumonia virus of mice (PVM), and Reovirus-3 (Reo-3); facility B showed a positive result only for E. cuniculi. The results of the second survey were similar to the first, except for the presence of Sendai virus; all animals from the two facilities were Sendai virus-negative in the second experiment. No pathogenic bacteria were cultured in the organs of any of the animals in the first survey. However, in the second survey, Bordetella bronchiseptica was cultured from the lung tissue of two 10-week-old animals from facility A. Chlamydial infection was examined by the Macchiavello method, but no animal showed positive results. Tests using fecal flotation or the KOH wet mount method showed no infection of endoparasites, protozoa, ectoparasites, or dermatophytes in any animal in both surveys. However, in the histopathological examination, an infection of protozoa-like organisms was observed in the cecum of some animals from facility A. The present study revealed that microbiological contamination was present in guinea pigs reared conventionally in two facilities in Korea, suggesting that there is a need to improve environmental conditions in order to eradicate microbial contamination.

  15. Fort Lewis Dining Facilities Consumer Survey

    Science.gov (United States)

    survey was to identify those factors which have the potential for influencing or determining consumer attendance at the dining hall. In general, the...an improvement of quality, preparation, and quantity of the food would be all that is necessary to draw the military customer back into the dining hall

  16. Orientation to pollution prevention for facility design

    Energy Technology Data Exchange (ETDEWEB)

    Raney, E.A.; Whitehead, J.K.; Encke, D.B. [Westinghouse Hanford Co., Richland, WA (United States); Dorsey, J.A. [Kaiser Engineers Hanford Co., Richland, WA (United States)

    1994-01-01

    This material was developed to assist engineers in incorporating pollution prevention into the design of new or modified facilities within the U.S. Department of Energy (DOE). The material demonstrates how the design of a facility can affect the generation of waste throughout a facility`s entire life and it offers guidance on how to prevent the generation of waste during design. Contents include: Orientation to pollution prevention for facility design training course booklet; Pollution prevention design guideline; Orientation to pollution prevention for facility design lesson plan; Training participant survey and pretest; and Training facilitator`s guide and schedule.

  17. Nuclear facilities in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    1991-01-01

    The information brochure is a survey of installed nuclear facilities in Germany, presenting on one page each a picture of a nuclear power plant together with the main relevant data, or of other type of nuclear facilities belonging to the nuclear fuel cycle (such as fuel production plant, fuel production plant, fuel element storage facilities, and facilities for spent fuel and waste management). (UA) [de

  18. Assessment of Recreational Facilities in Federal Capital City, Abuja, Nigeria

    Directory of Open Access Journals (Sweden)

    Cyril Kanayo Ezeamaka

    2016-06-01

    Full Text Available Abuja Master Plan provided development of adequate Green Areas and other Recreational Facilities within the Federal Capital City (FCC, as part of its sustainability principles and provided for these recreational facilities within each neighborhood (FCDA, 1979. However, there have been several recent foul cries about the negative development of recreational facilities and the abuse of the Master Plan in the FCC.  The motivation for carrying out this study arose from the observation that recreational facilities in Phase 1 of the Federal Capital City Abuja are not clearly developed as intended by the policy makers and thus, the need to identify the recreational facilities in the Phase 1 of FCC and observe their level of development as well as usage. The field survey revealed that the Central Business District and Gazupe have higher numbers of recreational facilities with 45 and 56. While Wuse II (A08 and Wuse II (A07 Districts have lesser recreational facilities with 10 and 17. The field survey further revealed that all the districts in Phase 1 have over 35% cases of land use changes from recreational facilities to other use. The survey shows that over 65% of these recreational facilities are fully developed. The study also shows that just about 11% of the recreational sporting facilities were developed in line with the Abuja Master Plan in Phase 1. The study revealed that recreational facilities in Phase 1 of the FCC, Abuja has not being developed in compliance with the Abuja Master Plan.

  19. Survey of tritium wastes and effluents in near-term fusion-research facilities

    International Nuclear Information System (INIS)

    Bickford, W.E.; Dingee, D.A.; Willingham, C.E.

    1981-08-01

    The use of tritium control technology in near-term research facilities has been studied for both the magnetic and inertial confinement fusion programs. This study focused on routine generation of tritium wastes and effluents, with little referene to accidents or facility decommissioning. This report serves as an independent review of the effectiveness of planned control technology and radiological hazards associated with operation. The facilities examined for the magnetic fusion program included Fusion Materials Irradiation Testing Facility (FMIT), Tritium Systems Test Assembly (TSTA), and Tokamak Fusion Test Reactor (TFTR) in the magnetic fusion program, while NOVA and Antares facilities were examined for the inertial confinement program

  20. Nuclear Science: a survey of funding, facilities, and manpower

    International Nuclear Information System (INIS)

    1975-01-01

    In 1973 the Committee on Nuclear Science of the National Research Council initiated a re-examination of aspects (funding, manpower, and facilities) of the organization and operation of nuclear science research in order to evaluate any changes in the preceding four years and implications of such changes. The reports of the three ad hoc panels established for this purpose (funding and level of effort, nuclear facilities, manpower and education) are presented. Although they identify current problems in nuclear science, these reports do not provide simple solutions; rather, they attempt to provide updated information for use as background for continuing decisions

  1. Western states uranium resource survey

    International Nuclear Information System (INIS)

    Tinney, J.F.

    1977-01-01

    ERDA's National Uranium Resource Evaluation (NURE) program was established to provide a comprehensive description of uranium resources in the United States. To carry out this task, ERDA has contracted with various facilities, including universities, private companies, and state agencies, to undertake projects such as airborne radiometric surveys, geological and geochemical studies, and the development of advanced geophysical technology. LLL is one of four ERDA laboratories systematically studying uranium distribution in surface water, groundwater, and lake and stream sediments. We are specifically responsible for surveying seven western states. This past year we have designed and installed facilities for delayed-neutron counting and neutron-activation analysis, completed seven orientation surveys, and analyzed several thousand field samples. Full-scale reconnaissance surveys began last fall

  2. A Biosecurity Survey in Kenya, November 2014 to February 2015.

    Science.gov (United States)

    Ndhine, Edwardina Otieno; Slotved, Hans-Christian; Osoro, Eric Mogaka; Olsen, Katja N; Rugutt, Moses; Wanjohi, Cathryn W; Mwanda, Walter; Kinyagia, Benson Mburu; Steenhard, Nina R; Hansen, John-Erik Stig

    2016-01-01

    A biosecurity survey was performed to gather information on the biosecurity level and laboratory capacity in Kenya for the purpose of providing information outlining relevant components for biosecurity legislation, biosecurity implementation, and enforcement of biosecurity measures in Kenya. This survey is, to the authors' knowledge, the first to be published from an African country. A total of 86 facilities with laboratories covering relevant categories, such as training laboratories, human diagnostic laboratories, veterinary diagnostic laboratories, and research laboratories, were selected to participate in the survey. Each facility was visited by a survey team and staff were asked to answer 29 groups of questions from a questionnaire. The survey showed that Kenyan laboratory facilities contain biological agents of biosecurity concern. The restrictions for these agents were found to be limited for several of the facilities, in that many laboratory facilities and storage units were open for access by either students or staff who had no need of access to the laboratory. The survey showed a great deal of confusion in the terms biosecurity and biosafety and a generally limited biosecurity awareness among laboratory personnel. The survey showed that the security of biological agents of biosecurity concern in many facilities does not meet the international requirements. The authors recommend developing a legal framework in Kenya for effective controls, including national biosecurity regulations, guidelines, and procedures, thereby reducing the risk that a Kenyan laboratory would be the source of a future biological attack.

  3. Interim Storage Facility decommissioning. Final report

    International Nuclear Information System (INIS)

    Johnson, R.P.; Speed, D.L.

    1985-01-01

    Decontamination and decommissioning of the Interim Storage Facility were completed. Activities included performing a detailed radiation survey of the facility, removing surface and imbedded contamination, excavating and removing the fuel storage cells, restoring the site to natural conditions, and shipping waste to Hanford, Washington, for burial. The project was accomplished on schedule and 30% under budget with no measurable exposure to decommissioning personnel

  4. Historical Survey of Nuclear Non-Proliferation in Estonia, 1946-1995

    International Nuclear Information System (INIS)

    Maremaee, Ello; Tankler, Hain; Putnik, Henno; Maalmann, Iige

    2003-12-01

    The report presents a historical survey on two of the nuclear facilities under the IAEA safeguards in Estonia - Sillamaee Uranium Extraction Factory and the Paldiski Submarine Training Centre. These facilities were a Soviet legacy and shall be decommissioned and it is only through a close international co-operation and technical assistance that it would be possible to solve all the problems arising at these facilities. The historical survey represents the best available information the authors were able to give on the nuclear facilities, which have functioned on the territory of Estonia. The historical survey was a joint co-operation initiative by the Estonian Radiation Protection Centre and the Swedish Nuclear Power Inspectorate. The historical survey will be presented to the IAEA as a volunteer supplement to the State Declaration according to the Additional Protocol (author)

  5. Survey of computer codes applicable to waste facility performance evaluations

    International Nuclear Information System (INIS)

    Alsharif, M.; Pung, D.L.; Rivera, A.L.; Dole, L.R.

    1988-01-01

    This study is an effort to review existing information that is useful to develop an integrated model for predicting the performance of a radioactive waste facility. A summary description of 162 computer codes is given. The identified computer programs address the performance of waste packages, waste transport and equilibrium geochemistry, hydrological processes in unsaturated and saturated zones, and general waste facility performance assessment. Some programs also deal with thermal analysis, structural analysis, and special purposes. A number of these computer programs are being used by the US Department of Energy, the US Nuclear Regulatory Commission, and their contractors to analyze various aspects of waste package performance. Fifty-five of these codes were identified as being potentially useful on the analysis of low-level radioactive waste facilities located above the water table. The code summaries include authors, identification data, model types, and pertinent references. 14 refs., 5 tabs

  6. The contribution of unimproved water and toilet facilities to pregnancy-related mortality in Afghanistan: analysis of the Afghan Mortality Survey.

    Science.gov (United States)

    Gon, Giorgia; Monzon-Llamas, Laura; Benova, Lenka; Willey, Barbara; Campbell, Oona M R

    2014-12-01

    To estimate the effect of unimproved household water and toilet facilities on pregnancy-related mortality in Afghanistan. The data source was a population-based cross-sectional study, the Afghan Mortality Survey 2010. Descriptive, univariate and multivariate logistic regression analyses were carried out, comparing 69 pregnancy-related deaths (cases) and 15386 surviving women (non-cases) who had a live birth or stillbirth between 2007 and 2010. After adjusting for confounders, households with unimproved water access had 1.91 the odds of pregnancy-related mortality [95% confidence interval (CI) 1.11-3.30] compared to households with improved water access. We also found an association between unimproved toilet facilities and pregnancy-related mortality (OR = 2.25; 95% CI 0.71-7.19; P-value = 0.169), but it was not statistically significant. Unimproved household water access was an important risk factor for pregnancy-related mortality in Afghanistan. However, we were unable to discern whether unimproved water source is a marker of unhygienic environments or socio-economic position. There was weak evidence for the association between unimproved toilet facilities and pregnancy-related mortality; this association requires confirmation from larger studies. © 2014 John Wiley & Sons Ltd.

  7. Nuclear safeguards surveys as performed by the Albuquerque operations office

    International Nuclear Information System (INIS)

    Jewell, D.

    1987-01-01

    The nuclear safeguards survey program as administered by the Albuquerque Operations Office (AL) is comprehensive in scope and evaluates the facility's safeguards program for an entire appraisal period. The survey program focuses on both the integrated and graded safeguards concepts and includes both compliance and performance evaluations. The program utilizes independent measurement support to verify facility inventory values and measurement system capabilities. The AL survey program is oriented towards facility development and management as opposed to development and management by numerous detailed departmental directives

  8. Mineral facilities of Asia and the Pacific

    Science.gov (United States)

    Baker, Michael S.; Elias, Nurudeen; Guzman, Eric; Soto-Viruet, Yadira

    2010-01-01

    This map displays over 1,500 records of mineral facilities throughout the continent of Asia and the countries of the Pacific Ocean. Each record represents one commodity and one facility type at a single geographic location. Facility types include mines, oil and gas fields, and plants, such as refineries, smelters, and mills. Common commodities of interest include aluminum, cement, coal, copper, gold, iron and steel, lead, nickel, petroleum, salt, silver, and zinc. Records include attributes, such as commodity, country, location, company name, facility type and capacity (if applicable), and latitude and longitude geographical coordinates (in both degrees-minutes-seconds and decimal degrees). The data shown on this map and in table 1 were compiled from multiple sources, including (1) the 2008 U.S. Geological Survey Minerals Yearbook (Asia and the Pacific volume), (2) minerals statistics and information from the U.S. Geological Survey Minerals Information Web site (http://minerals.usgs.gov/minerals/), and (3) data collected by U.S. Geological Survey minerals information country specialists. Other sources include statistical publications of individual countries, annual reports and press releases of operating companies, and trade journals. Due to the sensitivity of some energy commodity data, the quality of these data should be evaluated on a country-by-country basis. Additional information is available from the country specialists listed in table 2.

  9. Experience base for Radioactive Waste Thermal Processing Systems: A preliminary survey

    International Nuclear Information System (INIS)

    Mayberry, J.; Geimer, R.; Gillins, R.; Steverson, E.M.; Dalton, D.; Anderson, G.L.

    1992-04-01

    In the process of considering thermal technologies for potential treatment of the Idaho National Engineering Laboratory mixed transuranic contaminated wastes, a preliminary survey of the experience base available from Radioactive Waste Thermal Processing Systems is reported. A list of known commercial radioactive waste facilities in the United States and some international thermal treatment facilities are provided. Survey focus is upon the US Department of Energy thermal treatment facilities. A brief facility description and a preliminary summary of facility status, and problems experienced is provided for a selected subset of the DOE facilities

  10. Verification Survey of the Building 315 Zero Power Reactor-6 Facility, Argonne National Laboratory-East, Argonne, Illinois

    International Nuclear Information System (INIS)

    W. C. Adams

    2007-01-01

    Oak Ridge Institute for Science and Education (ORISE) conducted independent verification radiological survey activities at Argonne National Laboratory's Building 315, Zero Power Reactor-6 facility in Argonne, Illinois. Independent verification survey activities included document and data reviews, alpha plus beta and gamma surface scans, alpha and beta surface activity measurements, and instrumentation comparisons. An interim letter report and a draft report, documenting the verification survey findings, were submitted to the DOE on November 8, 2006 and February 22, 2007, respectively (ORISE 2006b and 2007). Argonne National Laboratory-East (ANL-E) is owned by the U.S. Department of Energy (DOE) and is operated under a contract with the University of Chicago. Fundamental and applied research in the physical, biomedical, and environmental sciences are conducted at ANL-E and the laboratory serves as a major center of energy research and development. Building 315, which was completed in 1962, contained two cells, Cells 5 and 4, for holding Zero Power Reactor (ZPR)-6 and ZPR-9, respectively. These reactors were built to increase the knowledge and understanding of fast reactor technology. ZPR-6 was also referred to as the Fast Critical Facility and focused on fast reactor studies for civilian power production. ZPR-9 was used for nuclear rocket and fast reactor studies. In 1967, the reactors were converted for plutonium use. The reactors operated from the mid-1960's until 1982 when they were both shut down. Low levels of radioactivity were expected to be present due to the operating power levels of the ZPR's being restricted to well below 1,000 watts. To evaluate the presence of radiological contamination, DOE characterized the ZPRs in 2001. Currently, the Melt Attack and Coolability Experiments (MACE) and Melt Coolability and Concrete Interaction (MCCI) Experiments are being conducted in Cell 4 where the ZPR-9 is located (ANL 2002 and 2006). ANL has performed final

  11. Low-level and mixed waste incinerator survey report

    International Nuclear Information System (INIS)

    Garcia, E.C.

    1988-10-01

    The Low-Level and Mixed Waste Survey Task was initiated to investigate and document current and planned incinerator facilities in the Department of Energy Defense Programs (DOE-DP) system. A survey was mailed to the DOE field offices requesting information regarding existing or planned incinerator facilities located under their jurisdiction. The information requested included type, capacities, uses, costs, and mechanical description of the incinerators. The results of this survey are documented in this report. Nine sites responded to the survey, with eight sites listing nine incineration units in several stages of operations. The Idaho National Engineering Laboratory listed two operational facilities. There are four incinerators that are planned for start-up in 1991. Of the existing incinerators, three are used mostly for low-level wastes, while the planned units will be used for low-level, mixed, and hazardous wastes. This report documents the current state of the incineration facilities in the DOE-DP system and provides a preliminary strategy for management of low-level wastes and a basis for implementing this strategy. 5 refs., 4 figs., 14 tabs

  12. Biosecurity measures in 48 isolation facilities managing highly infectious diseases.

    Science.gov (United States)

    Puro, Vincenzo; Fusco, Francesco M; Schilling, Stefan; Thomson, Gail; De Iaco, Giuseppina; Brouqui, Philippe; Maltezou, Helena C; Bannister, Barbara; Gottschalk, René; Brodt, Hans-Rheinhard; Ippolito, Giuseppe

    2012-06-01

    Biosecurity measures are traditionally applied to laboratories, but they may also be usefully applied in highly specialized clinical settings, such as the isolation facilities for the management of patients with highly infectious diseases (eg, viral hemorrhagic fevers, SARS, smallpox, potentially severe pandemic flu, and MDR- and XDR-tuberculosis). In 2009 the European Network for Highly Infectious Diseases conducted a survey in 48 isolation facilities in 16 European countries to determine biosecurity measures for access control to the facility. Security personnel are present in 39 facilities (81%). In 35 facilities (73%), entrance to the isolation area is restricted; control methods include electronic keys, a PIN system, closed-circuit TV, and guards at the doors. In 25 facilities (52%), identification and registration of all staff entering and exiting the isolation area are required. Access control is used in most surveyed centers, but specific lacks exist in some facilities. Further data are needed to assess other biosecurity aspects, such as the security measures during the transportation of potentially contaminated materials and measures to address the risk of an "insider attack."

  13. Classified facilities for environmental protection

    International Nuclear Information System (INIS)

    Anon.

    1993-02-01

    The legislation of the classified facilities governs most of the dangerous or polluting industries or fixed activities. It rests on the law of 9 July 1976 concerning facilities classified for environmental protection and its application decree of 21 September 1977. This legislation, the general texts of which appear in this volume 1, aims to prevent all the risks and the harmful effects coming from an installation (air, water or soil pollutions, wastes, even aesthetic breaches). The polluting or dangerous activities are defined in a list called nomenclature which subjects the facilities to a declaration or an authorization procedure. The authorization is delivered by the prefect at the end of an open and contradictory procedure after a public survey. In addition, the facilities can be subjected to technical regulations fixed by the Environment Minister (volume 2) or by the prefect for facilities subjected to declaration (volume 3). (A.B.)

  14. Technical basis for the performance of radiological surveys in support of nuclear facility decommissioning/deactivation utilizing the Laser-Assisted Ranging and Data System (LARADS)

    International Nuclear Information System (INIS)

    Wade, C.D.

    1997-06-01

    This document describes the implementation of the Laser-Assisted Ranging and Data System (LARADS) as it applies to performing radiological surveys on facility exterior and interior surfaces. The LARADS enables the system operator to document scanning measurements, stationary radiological measurements, and sample locations of surfaces, with the radiological readings and exact coordinates (<2 cm [0.8 in.] precision) automatically logged in real-time. After the survey is completed, the information is downloaded to a geographical information system, and the radiological information is overlaid on a digital picture of the survey area or may be generated as a computer- aided drafted drawing. The final product is a track map or contour of the survey area that clearly shows the area covered by the detector and the locations of elevated readings. The exact reproducibility of data facilitates locating hot spots for remediation and provides for objective review by regulators and verifiers

  15. Nevada Test Site Area 25. Radiological survey and cleanup project, 1974-1983. Final report

    International Nuclear Information System (INIS)

    McKnight, R.K.; Rosenberry, C.E.; Orcutt, J.A.

    1984-01-01

    This report describes radiological survey, decontamination and decommissioning of the Nevada Test Site (NTS) Area 25 facilities and land areas incorporated in the Nuclear Rocket Development Station (NRDS). Buildings, facilities and support systems used after 1959 for nuclear reactor and engine testing were surveyed for the presence of radioactive contamination. The cleanup was part of the Surplus Facilities Management Program funded by the Department of Energy's Richland Operations Office. The radiological survey portion of the project encompassed portable instrument surveys and removable contamination surveys (swipe) for alpha and beta plus gamma radiation contamination of facilities, equipment and land areas. Soil sampling was also accomplished. The majority of Area 25 facilities and land areas have been returned to unrestricted use. Remaining radiologically contaminated areas are posted with warning signs and barricades. 12 figures

  16. Improving and extending performance at synchrotron radiation facilities

    International Nuclear Information System (INIS)

    Jackson, A.

    1997-05-01

    Synchrotron radiation facilities around the world have now matured through three generations. The latest facilities have all met or exceeded their design specifications and are learning how to cope with the ever more demanding requests of the user community, especially concerning beam stability. The older facilities remain competitive by extending the unique features of their design, and by developing novel insertion devices. In this paper we survey the beam characteristics achieved at third-generation sources and explore the improvements made at earlier generation facilities

  17. Delivery of electroconvulsive therapy in Canada: a first national survey report on usage, treatment practice, and facilities.

    Science.gov (United States)

    Martin, Barry A; Delva, Nicholas John; Graf, Peter; Gosselin, Caroline; Enns, Murray W; Gilron, Ian; Jewell, Mark; Lawson, James Stuart; Milev, Roumen; Patry, Simon; Chan, Peter K Y

    2015-06-01

    The aims of this study were to document electroconvulsive therapy use in Canada with respect to treatment facilities and caseloads based on a survey of practice (Canadian Electroconvulsive Therapy Survey/Enquete Canadienne Sur Les Electrochocs-CANECTS/ECANEC) and to consider these findings in the context of guideline recommendations. All 1273 registered hospitals in Canada were contacted, and 175 sites were identified as providing electroconvulsive therapy; these sites were invited to complete a comprehensive questionnaire. The survey period was calendar year 2006 or fiscal year 2006/2007. National usage rates were estimated from the responses. Sixty-one percent of the sites completed the questionnaire; a further 10% provided caseload data. Seventy were identified as general; 31, as university teaching; and 21, as provincial psychiatric/other single specialty (psychiatric) hospitals. Caseload volumes ranged from a mean of fewer than 2 to greater than 30 treatments per week. Estimated national usage during the 1-year survey period was 7340 to 8083 patients (2.32-2.56 per 10,000 population) and 66,791 to 67,424 treatments (2.11-2.13 per 1000 population). The diagnostic indications, admission status, and protocols for course end points are described. The usage rates are in keeping with earlier Canadian data and with those from other jurisdictions. The difficulty obtaining caseload data from individual hospitals is indicative of the need for standardized data collection to support both clinical research and quality assurance. The wide variation in protocols for number of treatments per course indicates a need for better informed clinical guidelines. The broad range of caseload volumes suggests the need to review the economies of scale in the field.

  18. Case-Mix Adjustment of the Bereaved Family Survey.

    Science.gov (United States)

    Kutney-Lee, Ann; Carpenter, Joan; Smith, Dawn; Thorpe, Joshua; Tudose, Alina; Ersek, Mary

    2018-01-01

    Surveys of bereaved family members are increasingly being used to evaluate end-of-life (EOL) care and to measure organizational performance in EOL care quality. The Bereaved Family Survey (BFS) is used to monitor EOL care quality and benchmark performance in the Veterans Affairs (VA) health-care system. The objective of this study was to develop a case-mix adjustment model for the BFS and to examine changes in facility-level scores following adjustment, in order to provide fair comparisons across facilities. We conducted a cross-sectional secondary analysis of medical record and survey data from veterans and their family members across 146 VA medical centers. Following adjustment using model-based propensity weighting, the mean change in the BFS-Performance Measure score across facilities was -0.6 with a range of -2.6 to 0.6. Fifty-five (38%) facilities changed within ±0.5 percentage points of their unadjusted score. On average, facilities that benefited most from adjustment cared for patients with greater comorbidity burden and were located in urban areas in the Northwest and Midwestern regions of the country. Case-mix adjustment results in minor changes to facility-level BFS scores but allows for fairer comparisons of EOL care quality. Case-mix adjustment of the BFS positions this National Quality Forum-endorsed measure for use in public reporting and internal quality dashboards for VA leadership and may inform the development and refinement of case-mix adjustment models for other surveys of bereaved family members.

  19. ADA Compliance and Accessibility of Fitness Facilities in Western Wisconsin.

    Science.gov (United States)

    Johnson, Marquell J; Stoelzle, Hannah Y; Finco, Kristi L; Foss, Sadie E; Carstens, Katie

    2012-01-01

    The study expands the research on fitness facility accessibility by determining how compliant fitness facilities in rural western Wisconsin were with Title III of the Americans with Disabilities Act (ADA). Comparisons were made with 4 other studies that were conducted in different geographical regions. The study also examined fitness professionals' disability knowledge and awareness. An ADA fitness facility compliance instrument and a fitness professional disability awareness survey were used. Direct observation and physical measurements were taken during on-site visits to 16 of 36 eligible fitness facilities in rural western Wisconsin. Ten fitness professionals from participating facilities completed an online survey. Frequencies were used to analyze the results. None of the participating facilities were in 100% compliance with ADA. Customer service desk (84%) and path of travel throughout the facility (72%) were the highest compliance areas. Telephone (6%) and locker rooms (32%) were the lowest compliance areas. No fitness professional was trained in wheelchair transfers and very few had received training in providing services to individuals with disabilities. Fitness facility accessibility remains a concern nationally. Continued efforts need to be made to raise the awareness of ADA compliance among fitness professionals across the United States, especially in rural areas where fitness facility availability is limited.

  20. Survey commission of the Manche center

    International Nuclear Information System (INIS)

    2002-01-01

    The subjects discussed during the Survey commission of the storage center of the Manche CSCM, held in october 2001, are presented in this document. They deal with the site survey, the maintenance facilities realized on this installations, the tritium survey in the water and the CSCM operating. (A.L.B.)

  1. Wetland and Sensitive Species Survey Report for Y-12: Proposed Uranium Processing Facility (UPF)

    Energy Technology Data Exchange (ETDEWEB)

    Giffen, N.; Peterson, M.; Reasor, S.; Pounds, L.; Byrd, G.; Wiest, M. C.; Hill, C. C.

    2009-11-01

    This report summarizes the results of an environmental survey conducted at sites associated with the proposed Uranium Processing Facility (UPF) at the Y-12 National Security Complex in September-October 2009. The survey was conducted in order to evaluate potential impacts of the overall project. This project includes the construction of a haul road, concrete batch plant, wet soil storage area and dry soil storage area. The environmental surveys were conducted by natural resource experts at ORNL who routinely assess the significance of various project activities on the Oak Ridge Reservation (ORR). Natural resource staff assistance on this project included the collection of environmental information that can aid in project location decisions that minimize impacts to sensitive resource such as significant wildlife populations, rare plants and wetlands. Natural resources work was conducted in various habitats, corresponding to the proposed areas of impact. Thc credentials/qualifications of the researchers are contained in Appendix A. The proposed haul road traverses a number of different habitats including a power-line right-of-way. wetlands, streams, forest and mowed areas. It extends from what is known as the New Salvage Yard on the west to the Polaris Parking Lot on the east. This haul road is meant to connect the proposed concrete batch plant to the UPF building site. The proposed site of the concrete batch plant itself is a highly disturbed fenced area. This area of the project is shown in Fig. 1. The proposed Wet Soils Disposal Area is located on the north side of Bear Creek Road at the former Control Burn Study Area. This is a second growth arce containing thick vegetation, and extensive dead and down woody material. This area of the project is shown in Fig. 2. Thc dry soils storage area is proposed for what is currently known as the West Borrow Area. This site is located on the west side of Reeves Road south of Bear Creek Road. The site is an early successional

  2. Feasibility study to develop BNCT facility at the Indonesian research reactor

    International Nuclear Information System (INIS)

    Hastowo, H.

    2001-01-01

    A survey on the Indonesian research reactors and its supporting facilities has been done in order to check the possibility to install BNCT facility. Oncologists from several hospitals have been informing about the BNCT treatment for tumours and they give a positive response to support utilisation of the BNCT facility. Several aspects required to support the BNCT treatment have also been identified and related activities on that matter soon will be initiated. The interim result in our survey indicated that utilisation of the 30 MW Multipurpose reactor would not be possible from the technical point of view. Further study will be concentrated on the TRIGA reactor and an epithermal neutron beam facility at the thermal column of this reactor will be designed for further work. (author)

  3. End-of-Life Care and Discussions in Japanese Geriatric Health Service Facilities: A Nationwide Survey of Managing Directors' Viewpoints.

    Science.gov (United States)

    Kanoh, Asako; Kizawa, Yoshiyuki; Tsuneto, Satoru; Yokoya, Shoji

    2018-01-01

    Geriatric health service facilities (GHSFs) play important roles as intermediate care facilities for elderly individuals temporarily when they need rehabilitation before returning home. However, the number of residents spending their end-of-life (EOL) period in such facilities is increasing. To improve the quality of EOL care, end-of-life discussions (EOLDs) are recommended by some guidelines and studies. This study aimed to clarify the current practice of EOL care and EOLDs in GHSFs in Japan. We conducted a nationwide cross-sectional survey by mailing questionnaires about EOL care and EOLDs to 3437 GHSF managing directors. The questionnaire was developed through a literature review and discussion among the researchers and experts. Descriptive statistics summarized the data. We also analyzed the factors related to GHSFs conducting EOLDs using Fisher exact tests. The response rate was 20.7% (713 of 3437). Among the respondents, 75.2% (536 of 713) of GHSFs provided EOL care and 73.1% (521 of 713) conducted EOLDs. The most common reasons for difficulties in providing EOL care included the lack of EOL education for nurses and care workers, and their fear about caring for dying residents. End-of-life discussions were mostly initiated after the deterioration of a resident's condition and were conducted with families by physicians. Statistically significant factors of GHSFs conducting EOLDs included providing EOL education for nurses and care workers, availability of private room for critically ill residents, emergency on-call doctors, and EOL care. Adequate practical staff education programs for EOL care including EOLDs may be crucial for quality of end-of-life care in aged care facilities.

  4. NEUTRON GENERATOR FACILITY AT SFU: GEANT4 DOSE RATE PREDICTION AND VERIFICATION.

    Science.gov (United States)

    Williams, J; Chester, A; Domingo, T; Rizwan, U; Starosta, K; Voss, P

    2016-11-01

    Detailed dose rate maps for a neutron generator facility at Simon Fraser University were produced via the GEANT4 Monte Carlo framework. Predicted neutron dose rates throughout the facility were compared with radiation survey measurements made during the facility commissioning process. When accounting for thermal neutrons, the prediction and measurement agree within a factor of 2 or better in most survey locations, and within 10 % inside the vault housing the neutron generator. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Facility-level, state, and financial factors associated with changes in the provision of smoking cessation services in US substance abuse treatment facilities: Results from the National Survey of Substance Abuse Treatment Services 2006 to 2012.

    Science.gov (United States)

    Cohn, Amy; Elmasry, Hoda; Niaura, Ray

    2017-06-01

    Cigarette smoking is common among patients in substance abuse treatment. Tobacco control programs have advocated for integrated tobacco dependence treatment into behavioral healthcare, including within substance abuse treatment facilities (SATFs) to reduce the public health burden of tobacco use. This study used data from seven waves (2006 to 2012) of the National Survey of Substance Abuse Treatment Services (n=94,145) to examine state and annual changes in the provision of smoking cessation services within US SATFs and whether changes over time could be explained by facility-level (private vs public ownership, receipt of earmarks, facility admissions, acceptance of government insurance) and state-level factors (cigarette tax per pack, smoke free policies, and percent of CDC recommended tobacco prevention spending). Results showed that the prevalence of SATFs offering smoking cessation services increased over time, from 13% to 65%. The amount of tax per cigarette pack, accepting government insurance, government (vs private) ownership, facility admissions, and CDC recommended tobacco prevention spending (per state) were the strongest correlates of the provision of smoking cessation programs in SATFs. Facilities that received earmarks were less likely to provide cessation services. Adult smoking prevalence and state-level smoke free policies were not significant correlates of the provision of smoking cessation services over time. Policies aimed at increasing the distribution of tax revenues to cessation services in SATFs may offset tobacco-related burden among those with substance abuse problems. Copyright © 2017. Published by Elsevier Inc.

  6. Consumer Response to Gastrointestinal Illness Perceived To Originate from Food Service Facilities.

    Science.gov (United States)

    Garnett, Erin S; Gretsch, Stephanie R; Null, Clair; Moe, Christine L

    2016-10-01

    Consumer responses to food product recalls have been documented, but there is little information on how consumers respond to illnesses or outbreaks associated with food service facilities. This study uses an on-line survey of 885 adults conducted in 2012 to determine how respondents changed their dining behavior following personal experiences with and secondhand reports of gastrointestinal illness believed to be associated with food service facilities. In response to personally experiencing gastrointestinal illness that they attributed to a food service facility, 90% of survey participants reported that they avoided the implicated facility for a time following the incident; almost one-half decided to never return to the facility they believed had made them ill. In response to a secondhand report of gastrointestinal illness, 86% of respondents reported they would avoid the implicated facility for a time, and 22% said they would never return to the facility. After both personal experiences of illness and secondhand reports of illness, consumer responses were significantly more severe toward the implicated facility than toward all other food service facilities. Frequent diners avoided facilities for shorter periods of time and were less likely to never go back to a facility than were infrequent diners. The survey results indicate that 24 to 97 fewer meals were purchased per respondent, or a 11 to 20% reduction in meals purchased outside the home, in the year following respondents' illness. Future estimates of the economic burden of foodborne illnesses, including those caused by noroviruses, should consider the impacts on the food service industry attributable to changes in consumer behavior, in addition to health care costs and loss of productivity.

  7. Building 211 cyclotron characterization survey report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-30

    The Building 211 Cyclotron Characterization Survey includes an assessment of the radioactive and chemical inventory of materials stored within the facility; an evaluation of the relative distribution of accelerator-produced activation products within various cyclotron components and adjacent structures; measurement of the radiation fields throughout the facility; measurement and assessment of internal and external radioactive surface contamination on various equipment, facility structures, and air-handling systems; and an assessment of lead (Pb) paint and asbestos hazards within the facility.

  8. Near-bottom Multibeam Survey Capabilities in the US National Deep Submergence Facility (Invited)

    Science.gov (United States)

    Yoerger, D. R.; McCue, S. J.; Jason; Sentry Operations Groups

    2010-12-01

    The US National Deep Submergence Facility (NDSF) provides near-bottom multibeam mapping capabilities from the autonomous underwater vehicle Sentry and the remotely operated vehicle Jason. These vehicles can be used to depths of 4500 and 6500m respectively. Both vehicles are equipped with Reson 7125 400khz multibeam sonars as well as compatible navigation equipment (inertial navigation systems, doppler velocity logs, and acoustic navigation systems). These vehicles have produced maps of rugged Mid-Ocean Ridge terrain in the Galapagos Rift, natural oil and gas seeps off the coast of Southern California, deep coral sites in the Gulf of Mexico, and sites for the Ocean Observing Initiative off the coast of Oregon. Multibeam surveys are conducted from heights between 20 and 80 meters, allowing the scientific user to select the tradeoff between resolution and coverage rate. In addition to conventional bathymetric mapping, the systems have used to image methane bubble plumes from natural seeps. This talk will provide summaries of these mapping efforts and describe the data processing pipeline used to produce maps shortly after each dive. Development efforts to reduce navigational errors and reconcile discrepancies between adjacent swaths will also be described.

  9. Building Excellence: How Helping Charters Access Facilities Can Improve Opportunity for Idaho Kids

    Science.gov (United States)

    Robson, Kelly; Squire, Juliet

    2016-01-01

    To better understand charter leaders' experiences acquiring facilities, the authors conducted a survey of all charter school leaders in the state of Idaho. The leaders of 26 brick-and-mortar charter schools responded, representing 65 percent of all such charter schools in the state. The survey gathered a number of facilities-related data points,…

  10. Antimicrobial stewardship in long-term care facilities in Belgium: a questionnaire-based survey of nursing homes to evaluate initiatives and future developments

    Directory of Open Access Journals (Sweden)

    François Kidd

    2016-03-01

    Full Text Available Abstract Background The use of antimicrobials is intense and often inappropriate in long-term care facilities. Antimicrobial resistance has increased in acute and chronic care facilities, including those in Belgium. Evidence is lacking concerning antimicrobial stewardship programmes in chronic care settings. The medical coordinator practicing in Belgian nursing homes is a general practitioner designated to coordinate medical activity. He is likely to be the key position for effective implementation of such programmes. The aim of this study was to evaluate past, present, and future developments of antimicrobial stewardship programmes by surveying medical coordinators working in long-term care facilities in Belgium. Methods We conducted an online questionnaire-based survey of 327 Belgian medical coordinators. The questionnaire was composed of 33 questions divided into four sections: characteristics of the respondents, organisational frameworks for implementation of the antimicrobial stewardship programme, tools to promote appropriate antimicrobial use and priorities of action. Questions were multiple choice, rating scale, or free text. Results A total of 39 medical coordinators (12 % completed the questionnaire. Past or present antimicrobial stewardship initiatives were reported by 23 % of respondents. The possibility of future developments was rated 2.7/5. The proposed key role of medical coordinators was rated <3/5 by 36 % of respondents. General practitioners, nursing staff, and hospital specialists are accepted as important roles. The use of antimicrobial guidelines was reported by only 19 % of respondents. Education was considered the cornerstone for any future developments. Specific diagnostic recommendations were considered useful, but chest x-rays were judged difficult to undertake. The top priority identified was to reduce unnecessary treatment of asymptomatic urinary infections. Conclusions Our study shows that the implementation of

  11. 105-C Building characterization survey data report

    International Nuclear Information System (INIS)

    Miller, R.L.

    1997-01-01

    This report is a compilation of the 105-C Facility Characterization Survey data collected during the period of July 1, 1994, through September 30, 1994. The scope of the report is limited to the characterization of the 105-C Facility and surrounding site. Conclusions and recommendations regarding courses of future action are beyond the scope of this report. The survey data in this report reflects the current conditions and status of the 105-C Building, and is intended to be used in support of future decontamination and decommissioning activities. The survey was organized and implemented to evaluate the four parameters relating to the current condition of the facility. These parameters concern the physical conditions of the 105-C Building from a personnel safety standpoint; the radiological status throughout the building; identification of the hazardous materials located in the building; and identification of subsurface obstacles left in the path of proposed excavations

  12. Extremity dosimetry at US Department of Energy facilities

    International Nuclear Information System (INIS)

    Harty, R.; Reece, W.D.; MacLellan, J.A.

    1986-05-01

    A questionnaire on extremity dosimetry was distributed to DOE facilities along with a questionnaire on beta dosimetry. An informal telephone survey was conducted as a follow-up survey to answer a few additional questions concerning extremity monitoring practices. The responses to the questionnaire and the telephone survey are summarized in this report. Background information, developed from operational experience and a review of the current literature, is presented as a basis for understanding the information obtained by the survey and questionnaire

  13. Overview of US fast-neutron facilities and testing capabilities

    International Nuclear Information System (INIS)

    Evans, E.A.; Cox, C.M.; Jackson, R.J.

    1982-01-01

    Rather than attempt a cataloging of the various fast neutron facilities developed and used in this country over the last 30 years, this paper will focus on those facilities which have been used to develop, proof test, and explore safety issues of fuels, materials and components for the breeder and fusion program. This survey paper will attempt to relate the evolution of facility capabilities with the evolution of development program which use the facilities. The work horse facilities for the breeder program are EBR-II, FFTF and TREAT. For the fusion program, RTNS-II and FMIT were selected

  14. USDOE Remote Sensing Laboratory multisensor surveys

    International Nuclear Information System (INIS)

    Tinney, L.; Christel, L.; Clark, H.; Mackey, H.

    1996-01-01

    The United States Department of Energy (USDOE) maintains a Remote Sensing Laboratory (RSL) to support nuclear related programs of the US Government. The mission of the organization includes both emergency response and routine environmental assessments of nuclear facilities. The unique suite of equipment used by RSL for multisensor surveys of nuclear facilities include gamma radiation sensors, mapping quality aerial cameras, video cameras, thermal imagers, and multispectral scanners. Results for RSL multisensor surveys that have been conducted at the Savannah River Site (SRS) located in South Carolina are presented

  15. Assessment of Maternal Satisfaction with Facility-based Childbirth ...

    African Journals Online (AJOL)

    AJRH Managing Editor

    In Senegal, only 60% of mothers in rural areas deliver in health facilities. ... experience is one of the factors in their choosing to deliver in such facilities in ... maternal satisfaction with childbirth care and 23 standard care survey items was assessed. .... cost*. 0.64. Cheap. 30 (11.6). Affordable. 140 (54.1). Expensive. 68 (26.3).

  16. Manual for Accessibility: [Conference, Meeting, and Lodging Facilities]. Revised.

    Science.gov (United States)

    National Rehabilitation Association, Alexandria, VA.

    This illustrated manual and survey forms are designed to be used by organizations, hotel and restaurant associations, interested individuals and others as a guide for selecting accessible conference, meeting, and lodging facilities. The guidelines can also be used with existing facilities to identify specific modifications and accommodations. The…

  17. Pain treatment facilities: do we need quantity or quality?

    Science.gov (United States)

    de Meij, Nelleke; Köke, Albère; van der Weijden, Trudy; van Kleef, Maarten; Patijn, Jacob

    2014-10-01

    Chronic pain patients referred to a pain treatment facility have no guarantee that they will receive a proper diagnostic procedure or treatment. To obtain information about organizational aspects of pain treatment facilities and the content of their daily pain practice, we performed a questionnaire survey. The aim of the study was to evaluate the amount of pain treatment facilities, the content of organized specialized pain care and adherence to the criteria of the internationally accepted guidelines for pain treatment services. The University Pain Centre Maastricht in the Department of Anaesthesiology and Pain Management at Maastricht University Medical Centre developed a questionnaire survey based on the Recommendations for Pain Treatment Services of the International Association for the Study of Pain (IASP). The questionnaire was sent to the medical boards of all hospitals in the Netherlands (n=94). The response rate was 86% (n=81). Of all hospitals, 88.9% (n=72) reported the provision of organized specialized pain care, which was provided by a pain management team in 86.1% (n=62) and by an individual specialist in 13.9% (n=10). Insight was obtained from pain treatment facilities in five different domains: the organizational structure of pain management, composition of the pain team, pain team practice, patient characteristics, and research and education facilities. Although 88.9% of all hospitals stated that organized specialized pain care was provided, only a few hospitals could adhere to the criteria for pain treatment services of the IASP. The outcome of the questionnaire survey may help to define quality improvement standards for pain treatment facilities. © 2014 John Wiley & Sons, Ltd.

  18. Individually Linked Household and Health Facility Vaccination Survey in 12 At-risk Districts in Kinshasa Province, Democratic Republic of Congo: Methods and Metadata.

    Science.gov (United States)

    Burnett, Eleanor; Wannemuehler, Kathleen; Ngoie Mwamba, Guillaume; Yolande, Masembe; Guylain, Kaya; Muriel, Nzazi Nsambu; Cathy, Nzuzi; Patrice, Tshekoya; Wilkins, Karen; Yoloyolo, Norbert

    2017-07-01

    Health facility (HF) and household (HH) data can complement each other to provide a better understanding of the factors that contribute to vaccination status. In 12 zones with low vaccination coverage within Kinshasa Province, Democratic Republic of Congo, we conducted 2 surveys: (1) a linked HH and HF survey among 6-11-month-old infants, and (2) a HH survey among 12-23-month-old children. Linked survey objectives were to identify factors associated with vaccination status and to explore methodological considerations for linked survey implementation. To provide linked HH and HF data, we enrolled 6-11-month-old infants in HH clusters in each zone and then surveyed HFs located within the 12 zones and cited by caregivers of the enrolled infants as the most recent HF visited for vaccination or curative care. To provide vaccination coverage estimates for the 12-zone area, we enrolled 12-23-month-old children in every fourth HH. Of the HHs with a child aged 6-23 months, 16% were ineligible because they had resided in the neighborhood for one of the 182 surveyed HFs. For the coverage survey, 710 children aged 12-23 months participated. Home-based vaccination cards were available for 1210 of 1934 children (63%) surveyed. The surveys were successful in assessing HH information for 2 age groups, documenting written vaccination history for a large proportion of 6-23-month-old children, linking the majority of infants with their most recently visited HF, and surveying identified HFs. The implementation of the individually linked survey also highlighted the need for a comprehensive list of HFs and an analysis plan that addresses cross-classified clusters with only 1 child. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  19. Methods for nondestructive assay holdup measurements in shutdown uranium enrichment facilities

    International Nuclear Information System (INIS)

    Hagenauer, R.C.; Mayer, R.L. II.

    1991-09-01

    Measurement surveys of uranium holdup using nondestructive assay (NDA) techniques are being conducted for shutdown gaseous diffusion facilities at the Oak Ridge K-25 Site (formerly the Oak Ridge Gaseous Diffusion Plant). When in operation, these facilities processed UF 6 with enrichments ranging from 0.2 to 93 wt % 235 U. Following final shutdown of all process facilities, NDA surveys were initiated to provide process holdup data for the planning and implementation of decontamination and decommissioning activities. A three-step process is used to locate and quantify deposits: (1) high-resolution gamma-ray measurements are performed to generally define the relative abundances of radioisotopes present, (2) sizable deposits are identified using gamma-ray scanning methods, and (3) the deposits are quantified using neutron measurement methods. Following initial quantitative measurements, deposit sizes are calculated; high-resolution gamma-ray measurements are then performed on the items containing large deposits. The quantitative estimates for the large deposits are refined on the basis of these measurements. Facility management is using the results of the survey to support a variety of activities including isolation and removal of large deposits; performing health, safety, and environmental analyses; and improving facility nuclear material control and accountability records. 3 refs., 1 tab

  20. INDEPENDENT CONFIRMATORY SURVEY REPORT FOR THE SECTION 4 AREA AT THE RIO ALGOM AMBROSIA LAKE FACILITY AMBROSIA LAKE, NEW MEXICO

    International Nuclear Information System (INIS)

    Adams, W.C.

    2010-01-01

    Federal Regulations (CFR) Title 10, Part 40, Appendix A. The DP presents the geographical site, pertinent background information and the design for surface reclamation of the Section 4 evaporation ponds sediment material which is considered byproduct material as defined by the Atomic Energy Act of 1954. As per the CFR requirements, the DP addresses the disposal of the uranium mill tailings in a manner as to protect human health and the environment (NRC 2006). At the request of the NRC's Headquarters and Region IV Offices, the Oak Ridge Institute for Science and Education (ORISE) performed confirmatory radiological surveys of the Section 4 Area evaporation ponds at the RAM Ambrosia Lake facility in Ambrosia Lake, New Mexico. The objectives of the confirmatory survey were to verify that remedial actions were effective in meeting established release criteria and that documentation accurately and adequately described the final radiological conditions of the RAM Ambrosia Lake, Section 4 Areas.

  1. FFTF preoperational survey. Program report

    International Nuclear Information System (INIS)

    Twitty, B.L.; Bicehouse, H.J.

    1980-12-01

    The FFTF will become operational with criticality early in 1980. This facility is composed of the test reactor, fuel examination cells, expended fuel storage systems and fuel handling systems. The reactor and storage systems are sodium-cooled with the heat load dumped to the ambient air through heat exchangers. In order to assure that the operation of the FFTF has minimal impact on the environment, a monitoring program has been established. Prior to operation of a new facility, a preoperational environmental survey is required. It is the purpose of this report to briefly describe the environmental survey program and to provide the background data obtained during the preoperational phase of the survey program. Nine stations in the program of particular importance to FFTF are discussed in detail with results of monitoring given. No unexplained trends were noted

  2. Pilot Survey of Breast Cancer Management in Sub-Saharan Africa

    Directory of Open Access Journals (Sweden)

    Verna D.N.K. Vanderpuye

    2017-06-01

    Full Text Available Purpose: To understand the current state of breast cancer management in sub-Saharan Africa. Methods: We conducted an anonymous online survey of breast cancer management among African Organization for Research and Treatment in Cancer (AORTIC members by using a 42-question structured questionnaire in both English and French in 2013. Results: Twenty members from 19 facilities in 14 countries responded to the survey. Twelve members (60% belonged to a multidisciplinary breast cancer team. Radiotherapy equipment was available in seven facilities (36%, but equipment had down time at least once a week in four facilities. Available chemotherapy drugs included methotrexate, cyclophosphamide, fluorouracil, anthracyclines, and vincristine, whereas trastuzumab, taxanes, vinorelbine, and gemcitabine were available in few facilities. Core-needle biopsy was available in 16 facilities (84%; mammogram, in 17 facilities (89%; computed tomography scan, in 15 facilities (79%; magnetic resonance imaging, in 11 facilities (58%; and bone scans, in nine facilities (47%. It took an average of 1 to 3 weeks to report histopathology. Immunohistochemistry was available locally in eight facilities (42%, outside hospitals but within the country in seven facilities (37%, and outside the country in four facilities (21%. Thirteen facilities (68% performed axillary node dissections as part of a breast protocol. Neoadjuvant chemotherapy was the most common therapy for locally advanced breast cancer in 13 facilities (68%. In three facilities (16%, receptor status did not influence the prescription of hormone treatment. Conclusion: This pilot survey suggests that AORTIC members in sub-Saharan Africa continue to make gains in the provision of access to multidisciplinary breast cancer care, but the lack of adequate pathology and radiotherapy services is a barrier. Focused attention on in-country and regional training needs and improvement of health systems deliverables is urgently

  3. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    International Nuclear Information System (INIS)

    1994-01-01

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs

  4. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs.

  5. Preparedness of lower-level health facilities and the associated factors for the outpatient primary care of hypertension: Evidence from Tanzanian national survey.

    Science.gov (United States)

    Bintabara, Deogratius; Mpondo, Bonaventura C T

    2018-01-01

    Sub-Saharan Africa is experiencing a rapid rise in the burden of non-communicable diseases in both urban and rural areas. Data on health system preparedness to manage hypertension and other non-communicable diseases remains scarce. This study aimed to assess the preparedness of lower-level health facilities for outpatient primary care of hypertension in Tanzania. This study used data from the 2014-2015 Tanzania Service Provision Assessment survey. The facility was considered as prepared for the outpatient primary care of hypertension if reported at least half (≥50%) of the items listed from each of the three domains (staff training and guideline, basic diagnostic equipment, and basic medicines) as identified by World Health Organization-Service Availability and Readiness Assessment manual. Data were analyzed using Stata 14. An unadjusted logistic regression model was used to assess the association between outcome and explanatory variables. All variables with a P value facilities involved in the current study, about 68% were public facilities and 73% located in rural settings. Only 28% of the assessed facilities were considered prepared for the outpatient primary care of hypertension. About 9% and 42% of the assessed facilities reported to have at least one trained staff and guidelines for hypertension respectively. In multivariate analysis, private facilities [AOR = 2.7, 95% CI; 1.2-6.1], urban location [AOR = 2.2, 95% CI; 1.2-4.2], health centers [AOR = 5.2, 95% CI; 3.1-8.7] and the performance of routine management meetings [AOR = 2.6, 95% CI; 1.1-5.9] were significantly associated with preparedness for the outpatient primary care of hypertension. The primary healthcare system in Tanzania is not adequately equipped to cope with the increasing burden of hypertension and other non-communicable diseases. Rural location, public ownership, and absence of routine management meetings were associated with being not prepared. There is a need to strengthen the primary

  6. The environmental survey manual: Appendix D

    International Nuclear Information System (INIS)

    1987-08-01

    The purpose of this manual is to provide guidance to the Survey and Sampling and Analysis teams that conduct the one-time Environmental Survey of the major US Department of Energy operating facilities. This appendix contains procedures for chemical analysis of organics, inorganics, and radioisotopes

  7. WEAVE: the next generation wide-field spectroscopy facility for the William Herschel Telescope : The next generation wide-field spectroscopy facility for the William Herschel Telescope

    NARCIS (Netherlands)

    Dalton, Gavin; Trager, Scott C.; Abrams, Don Carlos; Carter, David; Bonifacio, Piercarlo; Aguerri, J. Alfonso L.; MacIntosh, Mike; Evans, Chris; Lewis, Ian; Navarro, Ramon; Agocs, Tibor; Dee, Kevin; Rousset, Sophie; Tosh, Ian; Middleton, Kevin; Pragt, Johannes; Terrett, David; Brock, Matthew; Benn, Chris; Verheijen, Marc; Cano Infantes, Diego; Bevil, Craige; Steele, Iain; Mottram, Chris; Bates, Stuart; Gribbin, Francis J.; Rey, Jürg; Rodriguez, Luis Fernando; Delgado, Jose Miguel; Guinouard, Isabelle; Walton, Nic; Irwin, Michael J.; Jagourel, Pascal; Stuik, Remko; Gerlofsma, Gerrit; Roelfsma, Ronald; Skillen, Ian; Ridings, Andy; Balcells, Marc; Daban, Jean-Baptiste; Gouvret, Carole; Venema, Lars; Girard, Paul

    We present the preliminary design of the WEAVE next generation spectroscopy facility for the William Herschel Telescope (WHT), principally targeting optical ground-based follow up of upcoming ground-based (LOFAR) and spacebased (Gaia) surveys. WEAVE is a multi-object and multi-IFU facility utilizing

  8. Report of radioactivity survey research in fiscal year 1989

    International Nuclear Information System (INIS)

    1990-12-01

    In the National Institute of Radiological Sciences, as a part of the radioactivity survey and research of Science and Technology Agency, the survey of environmental radioactivity level due to the radioactive fallout accompanying nuclear explosion experiments and the radioactive substances released from nuclear facilities and others and the safety analysis of these have been carried out. The radioactivity and dose survey for environment, foods and human bodies, the survey of the level around nuclear facilities, the business of radioactivity data center, the basic investigation for the evaluation of the results of radioactivity survey, the training of environmental radiation monitoring technicians and the investigation and research of the measurement of emergency radiation exposure and countermeasures were carried out. Those results are summarized. (K.I.)

  9. Benchmarking survey for recycling.

    Energy Technology Data Exchange (ETDEWEB)

    Marley, Margie Charlotte; Mizner, Jack Harry

    2005-06-01

    This report describes the methodology, analysis and conclusions of a comparison survey of recycling programs at ten Department of Energy sites including Sandia National Laboratories/New Mexico (SNL/NM). The goal of the survey was to compare SNL/NM's recycling performance with that of other federal facilities, and to identify activities and programs that could be implemented at SNL/NM to improve recycling performance.

  10. Environmental analysis of the operation of the ERDA facilities in Oak Ridge

    International Nuclear Information System (INIS)

    McWherter, J.R.

    1975-01-01

    An analysis of the environmental effects of current ERDA operations in Oak Ridge is being conducted to establish a baseline for the consideration of the environmental effects of additional facilities or modified operations in the future. An extensive ecological survey has been conducted for about one year; social and economic data were obtained; and an archaeological survey of the area was made. The facilities were described and the effluents associated with operations were quantified to the extent practical. The effects of effluent releases to the environment are being analyzed. The social effects of the ERDA facilities in Oak Ridge are also being studied. (auth)

  11. ORNL calibrations facility

    International Nuclear Information System (INIS)

    Berger, C.D.; Gupton, E.D.; Lane, B.H.; Miller, J.H.; Nichols, S.W.

    1982-08-01

    The ORNL Calibrations Facility is operated by the Instrumentation Group of the Industrial Safety and Applied Health Physics Division. Its primary purpose is to maintain radiation calibration standards for calibration of ORNL health physics instruments and personnel dosimeters. This report includes a discussion of the radioactive sources and ancillary equipment in use and a step-by-step procedure for calibration of those survey instruments and personnel dosimeters in routine use at ORNL

  12. Uniform Facility Data Set US (UFDS-1998)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Uniform Facility Data Set (UFDS) was designed to measure the scope and use of drug abuse treatment services in the United States. The survey collects information...

  13. Availability of emergency obstetric care (EmOC) among public and private health facilities in rural northwest Bangladesh.

    Science.gov (United States)

    Sikder, Shegufta S; Labrique, Alain B; Ali, Hasmot; Hanif, Abu A M; Klemm, Rolf D W; Mehra, Sucheta; West, Keith P; Christian, Parul

    2015-01-31

    Although safe motherhood strategies recommend that women seek timely care from health facilities for obstetric complications, few studies have described facility availability of emergency obstetric care (EmOC). We sought to describe and compare availability and readiness to provide EmOC among public and private health facilities commonly visited for pregnancy-related complications in two districts of northwest Bangladesh. We also described aspects of financial and geographic access to healthcare and key constraints to EmOC provision. Using data from a large population-based community trial, we identified and surveyed the 14 health facilities (7 public, 7 private) most frequently visited for obstetric complications and near misses as reported by women. Availability of EmOC was based on provision of medical services, assessed through clinician interviews and record review. Levels of EmOC availability were defined as basic or comprehensive. Readiness for EmOC provision was based on scores in four categories: staffing, equipment, laboratory capacity, and medicines. Readiness scores were calculated using unweighted averages. Costs of C-section procedures and geographic locations of facilities were described. Textual analysis was used to identify key constraints. The seven surveyed private facilities offered comprehensive EmOC compared to four of the seven public facilities. With 100% representing full readiness, mean EmOC readiness was 81% (range: 63%-91%) among surveyed private facilities compared to 67% (range: 48%-91%) in public facilities (p = 0.040). Surveyed public clinics had low scores on staffing and laboratory capacity (69%; 50%). The mean cost of the C-section procedure in private clinics was $77 (standard deviation: $16) and free in public facilities. The public sub-district facilities were the only facilities located in rural areas, with none providing comprehensive EmOC. Shortages in specialized staff were listed as the main barrier to EmOC provision in

  14. Description of the U.S. Geological Survey's water-quality sampling and water-level monitoring program at the Hallam Nuclear Facility, August through September 1997

    International Nuclear Information System (INIS)

    1997-01-01

    A water-quality and water-level program between the US Department of Energy (USDOE) and the US Geological Survey (USGS) was re-established in August 1997 to (1) collect one set of water-quality samples from 17 of the 19 USDOE monitor wells, and (2) make five water-level measurements during a 2-month period from the 19 USDOE monitor wells at the Hallam Nuclear Facility, Hallam, Nebraska. Data from these wells are presented

  15. Referral of children seeking care at private health facilities in Uganda

    DEFF Research Database (Denmark)

    Mbonye, Anthony K.; Buregyeya, Esther; Rutebemberwa, Elizeus

    2017-01-01

    Background In Uganda, referral of sick children seeking care at public health facilities is poor and widely reported. However, studies focusing on the private health sector are scanty. The main objective of this study was to assess referral practices for sick children seeking care at private health...... facilities in order to explore ways of improving treatment and referral of sick children in this sector. Methods A survey was conducted from August to October 2014 in Mukono district, central Uganda. Data was collected using a structured questionnaire supplemented by Focus Group Discussions and Key Informant...... interviews with private providers and community members. Results A total of 241 private health facilities were surveyed; 170 (70.5%) were registered drug shops, 59 (24.5%) private clinics and 12 (5.0%) pharmacies. Overall, 104/241 (43.2%) of the private health facilities reported that they had referred sick...

  16. The rule on granting subsidies for survey of hot drainage influences

    International Nuclear Information System (INIS)

    1980-01-01

    The regulation is established under the provisions of the law concerning the proper execution of subsidy budgets and the ordinance for enforcing the law, to execute these provisions. The subsidies under the ordinance for enforcing the law concerning the special account for the measures of promoting power source development are delivered according to the provisions of the regulation as well as the law concerning the proper execution of subsidy budgets and the ordinance for enforcing the law. Basic terms are defined, such as nuclear power generating facilities; business for arranging the survey facilities for hot drainage influences; business for the prior-survey of hot drainage; business for the survey of hot drainage influences; place of business; expected date of beginning the operation. The Minister of International Trade Industry delivers subsidies to a prefecture where nuclear power generating facilities are set up or expected to be set up, or its neighboring prefectures to cover all or a part of expenses necessary for the businesses for arranging the survey facilities for hot drainage influences, the prior-survey of hot drainage and the survey of hot drainage influences. Subsidies are paid during the specified periods ranging from 2 to 7 years. The subsidy delivered to a prefecture in each fiscal year is limited to from 5 to 14 million yen. An application for the subsidies shall be filed by an applicant prefecture to the Minister of International Trade Industry, attached with the specified summary reports of a subsidized business and nuclear power generating facilities. (Okada, K.)

  17. Uniform Facility Data Set US (UFDS-1997)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Uniform Facility Data Set (UFDS), formerly the National Drug and Alcohol Treatment Unit Survey or NDATUS, was designed to measure the scope and use of drug abuse...

  18. Economic impacts of zebra mussels on drinking water treatment and electric power generation facilities.

    Science.gov (United States)

    Connelly, Nancy A; O'Neill, Charles R; Knuth, Barbara A; Brown, Tommy L

    2007-07-01

    Invasions of nonnative species such as zebra mussels can have both ecological and economic consequences. The economic impacts of zebra mussels have not been examined in detail since the mid-1990s. The purpose of this study was to quantify the annual and cumulative economic impact of zebra mussels on surface water-dependent drinking water treatment and electric power generation facilities (where previous research indicated the greatest impacts). The study time frame was from the first full year after discovery in North America (Lake St. Clair, 1989) to the present (2004); the study area was throughout the mussels' North American range. A mail survey resulted in a response rate of 31% for electric power companies and 41% for drinking water treatment plants. Telephone interviews with a sample of nonrespondents assessed nonresponse bias; only one difference was found and adjusted for. Over one-third (37%) of surveyed facilities reported finding zebra mussels in the facility and almost half (45%) have initiated preventive measures to prevent zebra mussels from entering the facility operations. Almost all surveyed facilities (91%) with zebra mussels have used control or mitigation alternatives to remove or control zebra mussels. We estimated that 36% of surveyed facilities experienced an economic impact. Expanding the sample to the population of the study area, we estimated 267 million dollars (BCa 95% CI = 161 million dollars - 467 million dollars) in total economic costs for electric generation and water treatment facilities through late 2004, since 1989. Annual costs were greater (44,000 dollars/facility) during the early years of zebra mussel infestation than in recent years (30,000 dollars). As a result of this and other factors, early predictions of the ultimate costs of the zebra mussel invasion may have been excessive.

  19. Referral of children seeking care at private health facilities in Uganda.

    Science.gov (United States)

    Mbonye, Anthony K; Buregyeya, Esther; Rutebemberwa, Elizeus; Clarke, Siân E; Lal, Sham; Hansen, Kristian S; Magnussen, Pascal; LaRussa, Philip

    2017-02-14

    In Uganda, referral of sick children seeking care at public health facilities is poor and widely reported. However, studies focusing on the private health sector are scanty. The main objective of this study was to assess referral practices for sick children seeking care at private health facilities in order to explore ways of improving treatment and referral of sick children in this sector. A survey was conducted from August to October 2014 in Mukono district, central Uganda. Data was collected using a structured questionnaire supplemented by Focus Group Discussions and Key Informant interviews with private providers and community members. A total of 241 private health facilities were surveyed; 170 (70.5%) were registered drug shops, 59 (24.5%) private clinics and 12 (5.0%) pharmacies. Overall, 104/241 (43.2%) of the private health facilities reported that they had referred sick children to higher levels of care in the two weeks prior to the survey. The main constraints to follow referral advice as perceived by caretakers were: not appreciating the importance of referral, gender-related decision-making and negotiations at household level, poor quality of care at referral facilities, inadequate finances at household level; while the perception that referral leads to loss of prestige and profit was a major constraint to private providers. In conclusion, the results show that referral of sick children at private health facilities faces many challenges at provider, caretaker, household and community levels. Thus, interventions to address constraints to referral of sick children are urgently needed.

  20. Radiological characterization of the TAN-IET facility

    Energy Technology Data Exchange (ETDEWEB)

    Koeppen, L.D.; Rodriguez, S.V.; Wheeler, O.A.; Cadwell, E.D.; Simpson, O.D.

    1982-06-01

    The Initial Engine Test (IET) facility is located on the Idaho National Engineering Laboratory (INEL) site at the north end of Test Area North (TAN). The IET facility was constructed and used for the Aircraft Nuclear Propulsion Program during the 1950's and was later used for two other programs: the Space Nuclear Auxiliary Power Transient (SNAP-TRAN) and the Hallam Decontamination and Decommissioning Project. The facility is no longer in use, therefore, a complete radiological characterization was conducted at the IET site. The characterization included measurements of beta-gamma dose rates; beta-gamma and alpha surface contamination; concentrations of selected radionuclides in subsurface storage tanks, surface soil, the exhaust duct, stack and test pad; and a walk-over surface survey of the entire facility. The information contained in this report will be of great value as the IET facility goes through the decommissioning and decontamination process.

  1. Access over ownership: the case of meeting facilities in Lyngby

    DEFF Research Database (Denmark)

    Nielsen, Susanne Balslev; Brinkø, Rikke

    2016-01-01

    research process. The first survey investigates the City of Knowledge’s members attitude towards shared space in general with questions like, what are you most likely to share with others? And what would you like to gain access to? A workshop further explored motivations and practical needs. The second...... positive towards the concept of shared space, but more reluctant about sharing own facilities. A majority of the informants are often using externally owned facilities for meetings and events, and they prefer professional meeting facilities to schools, universities and sports facilities. This point...

  2. A study on the safety of radioactive waste incineration facilities

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Y C [Yonsei Univ., Seoul (Korea, Republic of); Park, W J; Lee, B S; Lee, S H [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of)

    1994-12-15

    The main scope of the project is the selection of some considerable items in design criteria of radioactive waste incineration facilities not only for the protection of workers and residents during operation but also for the safe disposal of ashes after incineration. The technological and regulational status on incineration technologies in domestic and foreign is surveyed and analyzed for providing such basic items which must be contained in the guideline for safe and appropriate design, construction and operation of the facilities. The contents of the project are summarized as follows; surveying the status on incineration technologies for both radioactive and non-radioactive wastes in domestic and foreign, surveying and analysing same related technical standards and regulations in domestic and foreign, picking out main considerable items and proposing a direction of further research.

  3. Hospital-acquired infections in a Nigerian tertiary health facility: An ...

    African Journals Online (AJOL)

    Hospital-acquired infections in a Nigerian tertiary health facility: An audit of surveillance reports. ... This study evaluated the occurrence of HAI in a foremost tertiary health facility over a 5-year period for the purpose of reinforcing control efforts. Materials and Methods: A retrospective survey of records from the infection control ...

  4. Nevada Test Site Area 25, Radiological Survey and Cleanup Project, 1974-1983 (a revised final report). Revision 1

    International Nuclear Information System (INIS)

    Miller, M.G.

    1984-12-01

    This report describes the radiological survey, decontamination and decommissioning (D and D) of the Nevada Test Site (NTS) Area 25 facilities and land areas incorporated in the Nuclear Rocket Development Station (NRDS). Buildings, facilities and support systems used after 1959 for nuclear reactor and engine testing were surveyed for the presence of radioactive contamination. The radiological survey portion of the project encompassed portable instrument surveys and removable contamination surveys (swipe) for beta plus gamma and alpha radioactive contamination of facilities, equipment and land areas. Soil sampling was also accomplished. The majority of Area 25 facilities and land areas have been returned to unrestricted use. Remaining radiologically contaminated areas are posted with warning signs and barricades. 9 references, 23 figures

  5. A summary of the geotechnical and environmental investigations pertaining to the Vaalputs national radioactive waste disposal facility

    International Nuclear Information System (INIS)

    Hambleton-Jones, B.B.; Levin, M.; Camisani-Calzolari, F.A.G.M.

    1986-08-01

    This report describes the geological environmental surveys that lead to the choice and final evaluation of the Vaalputs national facility for the disposal of radioactive waste. This survey looked at the geography, demography, ecology, meteorology, geology, geohydrology and background radiological characteristics of the Vaalputs radioactive waste facility

  6. Survey of prevalence of overweight body condition in laboratory-housed cynomolgus macaques (Macaca fascicularis).

    Science.gov (United States)

    Bauer, Sharon A; Leslie, Ken E; Pearl, David L; Fournier, Jocelyn; Turner, Patricia V

    2010-07-01

    Excessive weight gain has been reported to occur in captive cynomolgus macaques with little to no change in diet. Overweight body condition can result in development of hyperglycemia and type 2 diabetes and should be avoided. The purpose of this survey was to assess the prevalence of overweight cynomolgus macaques in North American research facilities, including breeding colonies and short-term and long-term facilities, and to describe current methods used to assess body condition. The survey consisted of 51 questions covering animal population demographics, body weight and body condition scoring, feeding, and behavior. Voluntary participants included veterinarians and animal care managers. Respondents from 13 facilities completed the survey, and information was collected on 17,500 cynomolgus macaques. The majority of surveyed facilities housed juvenile and young adult macaques. The reported prevalence of overweight (greater than 10% of ideal body weight) animals ranged between 0% and 20% and reportedly was more frequent in animals younger than 10 y. Most facilities had weight reduction strategies in place. Despite these programs, a significant proportion of animals were reported as being overweight. The results of this survey demonstrate that most North American facilities housing cynomolgus macaques recognize the importance of tracking body condition regularly. However, implementing effective weight reduction programs may be difficult in captive housing environments. Because of the potential for adverse health effects, facilities should have a means of regularly tracking body weight as well as an action plan for managing overweight animals.

  7. Preparedness of lower-level health facilities and the associated factors for the outpatient primary care of hypertension: Evidence from Tanzanian national survey.

    Directory of Open Access Journals (Sweden)

    Deogratius Bintabara

    Full Text Available Sub-Saharan Africa is experiencing a rapid rise in the burden of non-communicable diseases in both urban and rural areas. Data on health system preparedness to manage hypertension and other non-communicable diseases remains scarce. This study aimed to assess the preparedness of lower-level health facilities for outpatient primary care of hypertension in Tanzania.This study used data from the 2014-2015 Tanzania Service Provision Assessment survey. The facility was considered as prepared for the outpatient primary care of hypertension if reported at least half (≥50% of the items listed from each of the three domains (staff training and guideline, basic diagnostic equipment, and basic medicines as identified by World Health Organization-Service Availability and Readiness Assessment manual. Data were analyzed using Stata 14. An unadjusted logistic regression model was used to assess the association between outcome and explanatory variables. All variables with a P value < 0.2 were fitted into the multiple logistic regression models using a 5% significance level.Out of 725 health facilities involved in the current study, about 68% were public facilities and 73% located in rural settings. Only 28% of the assessed facilities were considered prepared for the outpatient primary care of hypertension. About 9% and 42% of the assessed facilities reported to have at least one trained staff and guidelines for hypertension respectively. In multivariate analysis, private facilities [AOR = 2.7, 95% CI; 1.2-6.1], urban location [AOR = 2.2, 95% CI; 1.2-4.2], health centers [AOR = 5.2, 95% CI; 3.1-8.7] and the performance of routine management meetings [AOR = 2.6, 95% CI; 1.1-5.9] were significantly associated with preparedness for the outpatient primary care of hypertension.The primary healthcare system in Tanzania is not adequately equipped to cope with the increasing burden of hypertension and other non-communicable diseases. Rural location, public ownership

  8. Workplace air monitoring and sampling practices at DOE facilities

    International Nuclear Information System (INIS)

    Swinth, K.L.; Kenoyer, J.L.; Selby, J.M.

    1987-01-01

    The Pacific Northwest Laboratory (PNL) surveyed the current air monitoring and sampling practices at U.S. Department of Energy (DOE) facilities as a part of an air monitoring upgrade task. A comprehensive questionnaire was developed and distributed to DOE contractors through the DOE field offices. Twenty-six facilities returned a completed questionnaire. Questionnaire replies indicate a large diversity in air sampling and monitoring practices among DOE facilities. The differences among the facilities exist in monitoring and sampling instrumentation, procedures, calibration, analytical methods, detection levels, and action levels. Many of these differences could be attributed to different operational needs. 5 references, 2 figures, 2 tables

  9. Decontamination and decommissioning of the Organic Moderated Reactor Experiment facility (OMRE)

    International Nuclear Information System (INIS)

    Hine, R.E.

    1980-09-01

    This report describes the decontamination and decommissioning (D and D) of the Organic Moderated Reactor Experiment (OMRE) facility performed from October 1977 through September 1979. This D and D project included removal of all the facilities and as much contaminated soil and rock as practical. Removal of the reactor pressure vessel was an unusually difficult problem, and an extraordinary, unexpected amount of activated rock and soil was removed. After removal of all significantly contaminated material, the site consisted of a 20-ft deep excavation surrounded by backfill material. Before this excavation was backfilled, it and the backfill material were radiologically surveyed and detailed records made of these surveys. After the excavation was backfilled and graded, the site surface was surveyed again and found to be essentially uncontaminated

  10. Detection of fatigue damage of high and medium pressure rotor by X-ray diffraction method. Survey and research of nondestructive examination of thermal power generation facilities

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Tatsuo; Suesada, Yasuhiko; Nishioka, Noriaki; Goto, Toru; Ito, Hitomi; Kadoya, Yoshikuni

    1987-03-25

    In recent years, the existing thermal power generation facilities have been required to be operated in securing dependability from the standpoints of the operating conditions which have been getting severer and the demands to use them for longer periods, accordingly it is hoped to establish the diagnostic technology of aged deterioration by the non-destructive examination method for the facilities. In the beginning of 1959 the Kansai Electric Power Co. surveyed the current situation of this technology at various thermal power generation turbine facilities and discovered that concerning the diagnostic technology of aged deterioration by the non-destructive examination method, there remained many matters untouched in the basic research field. The company consequently started a survey and research jointly with Mitsubishi Heavy Industries in the first half of 1959. This report summarizes the research on the detection of aged deterioration due to thermal fatigue of Cr-Mo-V rotor material by the X-ray diffraction method which was conducted during the full fiscal year of 1984 and the first half of FY 1985 as a part of the above joint research. With respect to the conditions for the detection method of thermal fatigue damages of dummy grooves of the high and medium pressure rotor by the application of the X-ray diffraction method, it is preferred to measure a diffraction strength curve of the diffraction surface by using a Co tube as X-ray tube and it is also desirable to use a position sensitive proportional counter tube for X-ray detector. (5 figs, 6 refs)

  11. The U.S. Geological Survey's TRIGA® reactor

    Science.gov (United States)

    DeBey, Timothy M.; Roy, Brycen R.; Brady, Sally R.

    2012-01-01

    The U.S. Geological Survey (USGS) operates a low-enriched uranium-fueled, pool-type reactor located at the Federal Center in Denver, Colorado. The mission of the Geological Survey TRIGA® Reactor (GSTR) is to support USGS science by providing information on geologic, plant, and animal specimens to advance methods and techniques unique to nuclear reactors. The reactor facility is supported by programs across the USGS and is organizationally under the Associate Director for Energy and Minerals, and Environmental Health. The GSTR is the only facility in the United States capable of performing automated delayed neutron analyses for detecting fissile and fissionable isotopes. Samples from around the world are submitted to the USGS for analysis using the reactor facility. Qualitative and quantitative elemental analyses, spatial elemental analyses, and geochronology are performed. Few research reactor facilities in the United States are equipped to handle the large number of samples processed at the GSTR. Historically, more than 450,000 sample irradiations have been performed at the USGS facility. Providing impartial scientific information to resource managers, planners, and other interested parties throughout the world is an integral part of the research effort of the USGS.

  12. Post remedial action survey report for Building 003, Santa Susana Field Laboratories, Rockwell International, Ventura County, California, October 1981; April 1982. Surplus Facilities Management Program

    International Nuclear Information System (INIS)

    Wynveen, R.A.; Smith, W.H.; Sholeen, C.M.; Justus, A.L.; Flynn, K.F.

    1983-10-01

    Rockwell International's Santa Susana Laboratories in Ventura County, California, have been the site of numerous Federally-funded projects involving the use of radioactive materials. One such project was the System for Nuclear Auxiliary Power (SNAP) Program. Building 003 on the Santa Susana site was used in conjunction with the SNAP Program and contained a highly shielded area designed for remote manipulation of radioactive materials. Such facilities are commonly referred to as hot caves. During the SNAP Program, fuel burnup samples were analyzed and irradiation experiments were evaluated in the Building 003 hot cave. Use of the hot cave facility ended when the SNAP Program was terminated in 1973. Subsequently, the Building 003 facilities were declared excess and were decontaminaed and decommissioned during the first half of calendar year 1975. At that time, the building was given a preliminary release. In 1981, a post-remedial-action (certification) survey of Building 003 was conducted at the request of the Department of Energy. Significant levels of residual contamination were found in various parts of the building. Consequently, additional decontamination was conducted by Rockwell International. A final post-remedial-action survey was conducted during April 1982, and those areas in Building 003 that had been found contaminated in 1981 were now found to be free of detectable radioactive contamination. Sludge samples taken from the sewer sump showed elevated levels of enriched uranium contaminant. Hence, all sewer lines within Building 003 were removed. This permitted unconditional release of the building for unrestricted use. However, the sewer lines exterior to the building, which remain in place, must be considered potentially contaminated and, therefore, subject to restricted use

  13. Impact of facility size and profit status on intermediate outcomes in chronic dialysis patients.

    Science.gov (United States)

    Frankenfield, D L; Sugarman, J R; Presley, R J; Helgerson, S D; Rocco, M V

    2000-08-01

    Little information is available regarding the influence of dialysis facility size or profit status on intermediate outcomes in chronic dialysis patients. We have combined data from the Health Care Financing Administration (HCFA) Core Indicators Project; the end-stage renal disease (ESRD) facility survey; and the HCFA On-Line Survey, Certification, and Reporting System to analyze trends in this area. For hemodialysis patients, larger facilities were more likely than smaller facilities to perform dialysis on patients who were younger than 65 years of age, black, or undergoing dialysis 2 years or more (P profit units (P reduction ratio, but not with hematocrit or serum albumin values. Facility profit status was not associated with these intermediate outcomes. For peritoneal dialysis patients, there were no significant differences in patient demographics based on facility size. More patients in nonprofit units had been undergoing dialysis 2 or more years than patients in for-profit units (P profit status.

  14. Solid state semiconductor detectorized survey meter

    International Nuclear Information System (INIS)

    Okamoto, Eisuke; Nagase, Yoshiyuki; Furuhashi, Masato

    1987-01-01

    Survey meters are used for measurement of gamma ray dose rate of the space and the surface contamination dencity that the atomic energy plant and the radiation facility etc. We have recently developed semiconductor type survey meter (Commercial name: Compact Survey Meter). This survey meter is a small-sized dose rate meter with excellent function. The special features are using semiconductor type detector which we have developed by our own technique, stablar wide range than the old type, long life, and easy to carry. Now we introduce the efficiency and the function of the survey meter. (author)

  15. A survey and analysis of demand for HANARO utilization

    International Nuclear Information System (INIS)

    Sohn, J. M.; Yoo, K.J. and others

    1999-03-01

    The purpose of this survey and analysis is to identify the level of demand for the HANARO utilization that will be applied to developing experimental facilities, to advertise the HANARO, and to find able staff members for user group organization. The demand survey was performed on a nationwide basis of universities, hospitals, research institute, industrial firms, and public institutions from May 7, 1998 to July 30, 1998 through the internet, electronic mail, mail or fax. This survey contains of two parts: the first part is to identify the demand for the experimental facilities of HANARO such as neutron beam, cold neutron beam, fuel and material irradiation testing, radioisotope, neutron activation analysis, boron neutron capture therapy, and neutron transmutation doping. The second part is to survey the intention of participating in the neutron beam user group, radioisotope user group, and fuel and material irradiation testing user group. 1,181 individuals have replied to the survey. The number of replies concerning the utilization of HANARO and the user groups are 3,374 and 440, respectively. The results of this demand survey will be analyzed and used to the study of a more active utilization and a more efficient management of HANARO. They will be applied to the future planning the development of the experimental facilities of HANARO. (author). 22 tabs., 30 figs

  16. KEWB facilities decontamination and disposition. Final report

    International Nuclear Information System (INIS)

    Ureda, B.F.

    1976-01-01

    The decontamination and disposition of the KEWB facilities, Buildings 073, 643, 123, and 793, are complete. All of the facility equipment, including reactor enclosure, reactor vessel, fuel handling systems, controls, radioactive waste systems, exhaust systems, electrical services, and protective systems were removed from the site. Buildings 643, 123, and 793 were completely removed, including foundations. The floor and portions of the walls of Building 073 were covered over by final grading. Results of the radiological monitoring and the final survey are presented. 9 tables, 19 figures

  17. Survey and assessment of radioactive waste management facilities in the United States. Section 2.5. Air-cooled vault storage facilities

    International Nuclear Information System (INIS)

    1986-01-01

    There are two basic types of air-cooled vaults for the storage of spent nuclear fuel or vitrified HLRW. The two types, differentiated by the method of air cooling used, are the open-vault concept and the closed-vault concept. The following aspects of these air-cooled vault storage facility concepts are discussed: description and operation of facilities; strucutral design considerations and analysis; nuclear design considerations and analyses; vault environmental design considerations; unique design features; and accident analysis

  18. Stockouts of HIV commodities in public health facilities in Kinshasa: Barriers to end HIV.

    Directory of Open Access Journals (Sweden)

    Tinne Gils

    Full Text Available Stockouts of HIV commodities increase the risk of treatment interruption, antiretroviral resistance, treatment failure, morbidity and mortality. The study objective was to assess the magnitude and duration of stockouts of HIV medicines and diagnostic tests in public facilities in Kinshasa, Democratic Republic of the Congo. This was a cross-sectional survey involving visits to facilities and warehouses in April and May 2015. All zonal warehouses, all public facilities with more than 200 patients on antiretroviral treatment (ART (high-burden facilities and a purposive sample of facilities with 200 or fewer patients (low-burden facilities in Kinshasa were selected. We focused on three adult ART formulations, cotrimoxazole tablets, and HIV diagnostic tests. Availability of items was determined by physical check, while stockout duration until the day of the survey visit was verified with stock cards. In case of ART stockouts, we asked the pharmacist in charge what the facility coping strategy was for patients needing those medicines. The study included 28 high-burden facilities and 64 low-burden facilities, together serving around 22000 ART patients. During the study period, a national shortage of the newly introduced first-line regimen Tenofovir-Lamivudine-Efavirenz resulted in stockouts of this regimen in 56% of high-burden and 43% of low-burden facilities, lasting a median of 36 (interquartile range 29-90 and 44 days (interquartile range 24-90 until the day of the survey visit, respectively. Each of the other investigated commodities were found out of stock in at least two low-burden and two high-burden facilities. In 30/41 (73% of stockout cases, the commodity was absent at the facility but present at the upstream warehouse. In 30/57 (54% of ART stockout cases, patients did not receive any medicines. In some cases, patients were switched to different ART formulations or regimens. Stockouts of HIV commodities were common in the visited facilities

  19. Variations in status of preparation of personal protective equipment for preventing norovirus gastroenteritis in long-term care facilities for the elderly.

    Science.gov (United States)

    Fujiki, Saori; Ishizaki, Tatsuro; Nakayama, Takeo

    2017-12-01

    Residents of long-term care facilities are highly susceptible to norovirus gastroenteritis, and each facility is concerned about the need to implement norovirus infection control. Among control measures, personal protective equipment (PPE), such as disposable gloves and masks, plays a major role in reducing infectious spread. However, the preparation status of PPE in facilities before infection outbreaks has not been reported. The aim was to clarify the implementation status of preventive measures for norovirus gastroenteritis and the cost of preparing the necessary PPE in long-term care facilities. A questionnaire survey of facilities affiliated with the Kyoto Prefecture and Osaka Prefecture branches of the Japan Association of Geriatric Health Services Facilities was conducted. The survey items were the characteristics of the facility, whether preventive measures had been implemented for norovirus gastroenteritis from October through the following March in both 2009 and 2010, and the quantities and unit prices of PPE prepared for preventive measures. Twenty-six (11.2%) of 232 surveyed facilities (as of August 2011) answered the survey. Among them, 24 (92.3%) in 2009 and 25 (96.2%) in 2010 reported having implemented preventive measures for norovirus gastroenteritis, while 21 facilities (80.8%) in 2009 and 22 facilities (84.6%) in 2010 had prepared PPE. The median total cost for preparing the PPE needed for the preventive measures was US $2601 (range US $221-9192) in 2009 and US $3904 (range US $305-6427) in 2010. Although the results need careful interpretation because of the low response rate, most of the surveyed long-term care facilities had implemented preventive measures for norovirus gastroenteritis. However, the cost of preparing the PPE needed for the preventive measures varied among the facilities. © 2017 John Wiley & Sons, Ltd.

  20. Survey procedure: Control and accountability of nuclear materials

    International Nuclear Information System (INIS)

    Van Ness, H.

    1987-02-01

    This procedure outlines the method by which the Department of Energy (DOE) San Francisco Operations Office (SAN) will plan and execute periodic field surveys of the Material Control and Accountability (MC and A) program and practices at designated contractors' facilities. The surveys will be conducted in accordance with DOE Order 5630.7, Control and Accountability of Nuclear Materials Surveys (7/8/81) to ascertain compliance with applicable DOE Orders and SAN Management Directives in the 5630 series, as well as the adequacy of the contractor's program and procedures. Surveys will be conducted by the Safeguards and Security Division of DOE-SAN. The survey team will review and evaluate the adequacy of the contractor's procedures and practices for nuclear material control and accounting by means of physical inventory, internal control, measurement and statistics, material control indicators, records and reports, and personnel training. The survey will include an audit of records and reports, observation of inventory procedures, an independent test of the inventory and a review and evaluation of the inventory differences, accidental losses, and normal operational losses as applicable to the facility to be surveyed

  1. Determinants of facility readiness for integration of family planning with HIV testing and counseling services: evidence from the Tanzania service provision assessment survey, 2014-2015.

    Science.gov (United States)

    Bintabara, Deogratius; Nakamura, Keiko; Seino, Kaoruko

    2017-12-22

    Global policy reports, national frameworks, and programmatic tools and guidance emphasize the integration of family planning and HIV testing and counseling services to ensure universal access to reproductive health care and HIV prevention. However, the status of integration between these two services in Tanzanian health facilities is unclear. This study examined determinants of facility readiness for integration of family planning with HIV testing and counseling services in Tanzania. Data from the 2014-2015 Tanzania Service Provision Assessment Survey were analyzed. Facilities were considered ready for integration of family planning with HIV testing and counseling services if they scored ≥ 50% on both family planning and HIV testing and counseling service readiness indices as identified by the World Health Organization. All analyses were adjusted for clustering effects, and estimates were weighted to correct for non-responses and disproportionate sampling. Descriptive, bivariate, and multivariate logistic regression analyses were performed. A total of 1188 health facilities were included in the study. Of all of the health facilities, 915 (77%) reported offering both family planning and HIV testing and counseling services, while only 536 (45%) were considered ready to integrate these two services. Significant determinants of facility readiness for integrating these two services were being government owned [AOR = 3.2; 95%CI, 1.9-5.6], having routine management meetings [AOR = 1.9; 95%CI, 1.1-3.3], availability of guidelines [AOR = 3.8; 95%CI, 2.4-5.8], in-service training of staff [AOR = 2.6; 95%CI, 1.3-5.2], and availability of laboratories for HIV testing [AOR = 17.1; 95%CI, 8.2-35.6]. The proportion of facility readiness for the integration of family planning with HIV testing and counseling in Tanzania is unsatisfactory. The Ministry of Health should distribute and ensure constant availability of guidelines, availability of rapid diagnostic

  2. Jake Garn Mission Simulator and Training Facility, Building 5, Historical Documentation

    Science.gov (United States)

    Slovinac, Trish; Deming, Joan

    2010-01-01

    In response to President George W. Bush's announcement in January 2004 that the Space Shuttle Program (SSP) would end in 2010, the National Aeronautics and Space Administration (NASA) completed a nation-wide historical survey and evaluation of NASA-owned facilities and properties (real property assets) at all its Centers and component facilities. The buildings and structures which supported the SSP were inventoried and assessed as per the criteria of eligibility for listing in the National Register of Historic Places (NRHP) in the context of this program. This study was performed in compliance with Section 110 of the National Historic Preservation Act (NHPA) of 1966 (Public Law 89-665), as amended; the National Environmental Policy Act (NEPA) of 1969 (Public Law 91-190); Executive Order (EO) 11593: Protection and Enhancement of the Cultural Environment; EO 13287, Preserve America, and other relevant legislation. As part of this nation-wide study, in September 2006, historical survey and evaluation of NASA-owned and managed facilities at was conducted by NASA's Lyndon B. Johnson Space Center (JSC) in Houston, Texas. The results of this study are presented in a report entitled, "Survey and Evaluation of NASA-owned Historic Facilities and Properties in the Context of the U.S. Space Shuttle Program, Lyndon B. Johnson Space Center, Houston, Texas," prepared in November 2007 by NASA JSC's contractor, Archaeological Consultants, Inc. As a result of this survey, the Jake Gam Mission Simulator and Training Facility (Building 5) was determined eligible for listing in the NRHP, with concurrence by the Texas State Historic Preservation Officer (SHPO). The survey concluded that Building 5 is eligible for the NRHP under Criteria A and C in the context of the U.S. Space Shuttle program (1969-2010). Because it has achieved significance within the past 50 years, Criteria Consideration G applies. At the time of this documentation, Building 5 was still used to support the SSP as an

  3. Decommissioning of nuclear facilities involving operations with uranium and thorium

    International Nuclear Information System (INIS)

    Shum, E.Y.; Neuder, S.M.

    1990-01-01

    When a licensed nuclear facility ceases operation, the U.S. Nuclear Regulatory Commission (NRC) ensures that the facility and its site are decontaminated to acceptable levels so they may safely be released for unrestricted public use. Because specific environmental standards or broad federal guidelines governing release of residual radioactive contamination have not been issued, NRC has developed ad hoc cleanup criteria for decommissioning nuclear facilities that involved uranium and thorium. Cleanup criteria include decontamination of buildings, equipment, and land. We will address cleanup criteria and their rationale; procedures for decommissioning uranium/thorium facilities; radiological survey designs and procedures; radiological monitoring and measurement; and cost-effectiveness to demonstrate compliance

  4. LAMOST spectral survey — An overview

    International Nuclear Information System (INIS)

    Zhao Gang; Zhao Yongheng; Chu Yaoquan; Deng Licai; Jing Yipeng

    2012-01-01

    LAMOST (Large sky Area Multi-Object fiber Spectroscopic Telescope) is a Chinese national scientific research facility operated by National Astronomical Observatories, Chinese Academy of Sciences (NAOC). After two years of commissioning beginning in 2009, the telescope, instruments, software systems and operations are nearly ready to begin the main science survey. Through a spectral survey of millions of objects in much of the northern sky, LAMOST will enable research in a number of contemporary cutting edge topics in astrophysics, such as discovery of the first generation stars in the Galaxy, pinning down the formation and evolution history of galaxies — especially the Milky Way and its central massive black hole, and looking for signatures of the distribution of dark matter and possible sub-structures in the Milky Way halo. To maximize the scientific potential of the facility, wide national participation and international collaboration have been emphasized. The survey has two major components: the LAMOST ExtraGAlactic Survey (LEGAS) and the LAMOST Experiment for Galactic Understanding and Exploration (LEGUE). Until LAMOST reaches its full capability, the LEGUE portion of the survey will use the available observing time, starting in 2012. An overview of the LAMOST project and the survey that will be carried out in the next five to six years is presented in this paper. The science plan for the whole LEGUE survey, instrumental specifications, site conditions, and the descriptions of the current on-going pilot survey, including its footprints and target selection algorithm, will be presented as separate papers in this volume.

  5. The Size and Scope of Collegiate Athletic Training Facilities and Staffing.

    Science.gov (United States)

    Gallucci, Andrew R; Petersen, Jeffrey C

    2017-08-01

      Athletic training facilities have been described in terms of general design concepts and from operational perspectives. However, the size and scope of athletic training facilities, along with staffing at different levels of intercollegiate competition, have not been quantified.   To define the size and scope of athletic training facilities and staffing levels at various levels of intercollegiate competition. To determine if differences existed in facilities (eg, number of facilities, size of facilities) and staffing (eg, full time, part time) based on the level of intercollegiate competition.   Cross-sectional study.   Web-based survey.   Athletic trainers (ATs) who were knowledgeable about the size and scope of athletic training programs.   Athletic training facility size in square footage; the AT's overall facility satisfaction; athletic training facility component spaces, including satellite facilities, game-day facilities, offices, and storage areas; and staffing levels, including full-time ATs, part-time ATs, and undergraduate students.   The survey was completed by 478 ATs (response rate = 38.7%) from all levels of competition. Sample means for facilities were 3124.7 ± 4425 ft 2 (290.3 ± 411 m 2 ) for the central athletic training facility, 1013 ± 1521 ft 2 (94 ± 141 m 2 ) for satellite athletic training facilities, 1272 ± 1334 ft 2 (118 ± 124 m 2 ) for game-day athletic training facilities, 388 ± 575 ft 2 (36 ± 53 m 2 ) for athletic training offices, and 424 ± 884 ft 2 (39 ± 82 m 2 ) for storage space. Sample staffing means were 3.8 ± 2.5 full-time ATs, 1.6 ± 2.5 part-time ATs, 25 ± 17.6 athletic training students, and 6.8 ± 7.2 work-study students. Division I schools had greater resources in multiple categories (P facilities in recent years was common, and almost half of ATs reported that upgrades have been approved for the near future.   This study provides benchmark descriptive data on athletic training staffing and

  6. Household trends in access to improved water sources and sanitation facilities in Vietnam and associated factors: findings from the Multiple Indicator Cluster Surveys, 2000-2011.

    Science.gov (United States)

    Tuyet-Hanh, Tran Thi; Lee, Jong-Koo; Oh, Juhwan; Van Minh, Hoang; Ou Lee, Chul; Hoan, Le Thi; Nam, You-Seon; Long, Tran Khanh

    2016-01-01

    Despite progress made by the Millennium Development Goal (MDG) number 7.C, Vietnam still faces challenges with regard to the provision of access to safe drinking water and basic sanitation. This paper describes household trends in access to improved water sources and sanitation facilities separately, and analyses factors associated with access to improved water sources and sanitation facilities in combination. Secondary data from the Vietnam Multiple Indicator Cluster Survey in 2000, 2006, and 2011 were analyzed. Descriptive statistics and tests of significance describe trends over time in access to water and sanitation by location, demographic and socio-economic factors. Binary logistic regressions (2000, 2006, and 2011) describe associations between access to water and sanitation, and geographic, demographic, and socio-economic factors. There have been some outstanding developments in access to improved water sources and sanitation facilities from 2000 to 2011. In 2011, the proportion of households with access to improved water sources and sanitation facilities reached 90% and 77%, respectively, meeting the 2015 MDG targets for safe drinking water and basic sanitation set at 88% and 75%, respectively. However, despite these achievements, in 2011, only 74% of households overall had access to combined improved drinking water and sanitation facilities. There were also stark differences between regions. In 2011, only 47% of households had access to both improved water and sanitation facilities in the Mekong River Delta compared with 94% in the Red River Delta. In 2011, households in urban compared to rural areas were more than twice as likely (odds ratio [OR]: 2.2; 95% confidence interval [CI]: 1.9-2.5) to have access to improved water and sanitation facilities in combination, and households in the highest compared with the lowest wealth quintile were over 40 times more likely (OR: 42.3; 95% CI: 29.8-60.0). More efforts are required to increase household access to

  7. Employee influenza vaccination in residential care facilities.

    Science.gov (United States)

    Apenteng, Bettye A; Opoku, Samuel T

    2014-03-01

    The organizational literature on infection control in residential care facilities is limited. Using a nationally representative dataset, we examined the organizational factors associated with implementing at least 1 influenza-related employee vaccination policy/program, as well as the effect of vaccination policies on health care worker (HCW) influenza vaccine uptake in residential care facilities. The study was a cross-sectional study using data from the 2010 National Survey of Residential Care Facilities. Multivariate logistic regression analysis was used to address the study's objectives. Facility size, director's educational attainment, and having a written influenza pandemic preparedness plan were significantly associated with the implementation of at least 1 influenza-related employee vaccination policy/program, after controlling for other facility-level factors. Recommending vaccination to employees, providing vaccination on site, providing vaccinations to employees at no cost, and requiring vaccination as a condition of employment were associated with higher employee influenza vaccination rates. Residential care facilities can improve vaccination rates among employees by adopting effective employee vaccination policies. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  8. Personnel neutron dosimetry at Department of Energy facilities

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Endres, G.W.R.; Selby, J.M.; Vallario, E.J.

    1980-08-01

    This study assesses the state of personnel neutron dosimetry at DOE facilities. A survey of the personnel dosimetry systems in use at major DOE facilities was conducted, a literature search was made to determine recent advances in neutron dosimetry, and several dosimetry experts were interviewed. It was concluded that personnel neutron dosimeters do not meet current needs and that serious problems exist now and will increase in the future if neutron quality factors are increased and/or dose limits are lowered

  9. Can facility management contribute to study success?

    NARCIS (Netherlands)

    Kok, H.B; Mobach, Mark P.; Omta, S.W.F.; Alexander, K.

    2013-01-01

    Purpose– The present paper aims to explore to what extent the quality of facility services can be related to the differences in educational achievements in higher education. Design/methodology/approach - This paper is based on the first preliminary analyses of a national online survey among 1,752

  10. International Energy Agency instrumented facilities survey for solar assisted low energy dwellings

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-02-01

    Compiled are surveys outlining the instrumentation of 38 active and passive solar projects in 9 countries (Denmark, Italy, Japan, Netherlands, Sweden, Switzerland, United Kingdom, United States, and West Germany). After the surveys themselves are presented, the data are rearranged to compare answers from similar survey questions for each of the projects. These questions address building, solar system and instrumentation descriptions and meteorological, solar system and building system instrumentatation capabilities. (LEW)

  11. The experimental facility of Tournemire; La station experimentale de Tournemire

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-10-01

    This document presents the underground facility of Tournemire (Aveyron, France). The Tournemire abandoned railway tunnel gives access to a 250 m thick Jurassic clay bed covered with 250 m of limestones. The main goal of the Tournemire project is the study of the mechanical properties and fracturing of a clay formation and of its ability to be used as a deep underground storage facility for radioactive wastes. The document comprises a general presentation brochure and a description of the geologic, tectonic, geomechanical and hydro-geochemical surveys carried out in the facility. (J.S.)

  12. Energy and communal patrimony - 2012 survey. Study synthesis

    International Nuclear Information System (INIS)

    Lafitte, Bruno; Lestage, Christophe; Rozo, Ariane; Bisson, Nicolas; Pouillot, Jean-Pierre; Tessier, Philippe; Belon, Daniel; Caron, Clotilde

    2014-06-01

    This report proposes a synthesis of a study based on a survey on energy consumption and expenditures directly paid by local communities, the built patrimony, public lighting and vehicle fuel, the electricity consumptions and expenditures of drinking water stations, sewage treatment plants and waste treatment plants. The survey has been performed among more than 1600 towns and communities of more than 500 inhabitants in metropolitan France and overseas territories. The considered built patrimony comprises schools, swimming pools, other sport facilities, administrative buildings, social and cultural facilities, and other various facilities. The report indicates key figures for 2012 in terms of global assessment, main consumer sectors, buildings, public lighting, vehicle fuel, actions for energy management, and renewable energies. The evolution of consumptions and expenditures is then analysed (evolution of main indicators, market shares of energies in buildings)

  13. Hanford Site Near-Facility Environmental Monitoring Data Report for Calendar Year 2008

    Energy Technology Data Exchange (ETDEWEB)

    Perkins, Craig J.; Dorsey, Michael C.; Mckinney, Stephen M.; Wilde, Justin W.; Poston, Ted M.

    2009-09-15

    Near-facility environmental monitoring is defined as monitoring near facilities that have the potential to discharge or have discharged, stored, or disposed of radioactive or hazardous materials. Monitoring locations are associated with nuclear facilities such as the Plutonium Finishing Plant, Canister Storage Building, and the K Basins; inactive nuclear facilities such as N Reactor and the Plutonium-Uranium Extraction (PUREX) Facility; and waste storage or disposal facilities such as burial grounds, cribs, ditches, ponds, tank farms, and trenches. Much of the monitoring consists of collecting and analyzing environmental samples and methodically surveying areas near facilities. The program is also designed to evaluate acquired analytical data, determine the effectiveness of facility effluent monitoring and controls, assess the adequacy of containment at waste disposal units, and detect and monitor unusual conditions.

  14. Predictors of chain acquisition among independent dialysis facilities.

    Science.gov (United States)

    Pozniak, Alyssa S; Hirth, Richard A; Banaszak-Holl, Jane; Wheeler, John R C

    2010-04-01

    To determine the predictors of chain acquisition among independent dialysis providers. Retrospective facility-level data combined from CMS Cost Reports, Medical Evidence Forms, Annual Facility Surveys, and claims for 1996-2003. Independent dialysis facilities' probability of acquisition by a dialysis chain (overall and by chain size) was estimated using a discrete time hazard rate model, controlling for financial and clinical performance, practice patterns, market factors, and other facility characteristics. The sample includes all U.S. freestanding dialysis facilities that report not being chain affiliated for at least 1 year between 1997 and 2003. Above-average costs and better quality outcomes are significant determinants of dialysis chain acquisition. Facilities in larger markets were more likely to be acquired by a chain. Furthermore, small dialysis chains have different acquisition strategies than large chains. Dialysis chains appear to employ a mix of turn-around and cream-skimming strategies. Poor financial health is a predictor of chain acquisition as in other health care sectors, but the increased likelihood of chain acquisition among higher quality facilities is unique to the dialysis industry. Significant differences among predictors of acquisition by small and large chains reinforce the importance of using a richer classification for chain status.

  15. Service quality for facilities management in hospitals

    CERN Document Server

    Sui Pheng, Low

    2016-01-01

    This book examines the Facilities Management (FM) of hospitals and healthcare facilities, which are among the most complex, costly and challenging kind of buildings to manage. It presents and evaluates the FM service quality standards in Singapore’s hospitals from the patient’s perspective, and provides recommendations on how to successfully improve FM service quality and achieve higher patient satisfaction. The book also features valuable supplementary materials, including a checklist of 32 key factors for successful facilities management and another checklist of 24 service attributes for hospitals to achieve desirable service quality in connection with facilities management. The book adopts a unique approach of combining service quality and quality theory to provide a more holistic view of how FM service quality can be achieved in hospitals. It also integrates three instruments, namely the SERVQUAL model, the Kano model and the QFD model to yield empirical results from surveys for implementation in hosp...

  16. Environmental Protection Agency (EPA) Facility Registry Service (FRS) Power Plants

    Data.gov (United States)

    Department of Homeland Security — This GIS dataset contains data on wastewater treatment plants, based on EPA's Facility Registry Service (FRS) and NPDES, along with Clean Watersheds Needs Survey...

  17. Mineral facilities of Europe

    Science.gov (United States)

    Almanzar, Francisco; Baker, Michael S.; Elias, Nurudeen; Guzman, Eric

    2010-01-01

    This map displays over 1,700 records of mineral facilities within the countries of Europe and western Eurasia. Each record represents one commodity and one facility type at a single geographic location. Facility types include mines, oil and gas fields, and plants, such as refineries, smelters, and mills. Common commodities of interest include aluminum, cement, coal, copper, gold, iron and steel, lead, nickel, petroleum, salt, silver, and zinc. Records include attributes, such as commodity, country, location, company name, facility type and capacity (if applicable), and latitude and longitude geographical coordinates (in both degrees-minutes-seconds and decimal degrees). The data shown on this map and in table 1 were compiled from multiple sources, including (1) the most recently available data from the U.S. Geological Survey (USGS) Minerals Yearbook (Europe and Central Eurasia volume), (2) mineral statistics and information from the USGS Minerals Information Web site (http://minerals.usgs.gov/minerals/pubs/country/europe.html), and (3) data collected by the USGS minerals information country specialists from sources, such as statistical publications of individual countries, annual reports and press releases of operating companies, and trade journals. Data reflect the most recently published table of industry structure for each country at the time of this publication. Additional information is available from the country specialists listed in table 2.

  18. Implementation of tuberculosis infection control in health facilities in Mukono and Wakiso districts, Uganda.

    Science.gov (United States)

    Buregyeya, Esther; Nuwaha, Fred; Verver, Suzanne; Criel, Bart; Colebunders, Robert; Wanyenze, Rhoda; Kalyango, Joan N; Katamba, Achilles; Mitchell, Ellen Mh

    2013-08-01

    Tuberculosis infection control (TBIC) is rarely implemented in the health facilities in resource limited settings. Understanding the reasons for low level of implementation is critical. The study aim was to assess TBIC practices and barriers to implementation in two districts in Uganda. We conducted a cross-sectional study in 51 health facilities in districts of Mukono and Wakiso. The study included: a facility survey, observations of practices and eight focus group discussions with health workers. Quantitative: Only 16 facilities (31%) had a TBIC plan. Five facilities (10%) were screening patients for cough. Two facilities (4%) reported providing masks to patients with cough. Ventilation in the waiting areas was inadequate for TBIC in 43% (22/51) of the facilities. No facility possessed N95 particulate respirators. Qualitative: Barriers that hamper implementation of TBIC elicited included: under-staffing, lack of space for patient separation, lack of funds to purchase masks, and health workers not appreciating the importance of TBIC. TBIC measures were not implemented in health facilities in the two Ugandan districts where the survey was done. Health system factors like lack of staff, space and funds are barriers to implement TBIC. Effective implementation of TBIC measures occurs when the fundamental health system building blocks--governance and stewardship, financing, infrastructure, procurement and supply chain management are in place and functioning appropriately.

  19. A cross-sectional survey of essential surgical capacity in Somalia.

    Science.gov (United States)

    Elkheir, Natalie; Sharma, Akshay; Cherian, Meena; Saleh, Omar Abdelrahman; Everard, Marthe; Popal, Ghulam Rabani; Ibrahim, Abdi Awad

    2014-05-07

    To assess life-saving and disability-preventing surgical services (including emergency, trauma, obstetrics, anaesthesia) of health facilities in Somalia and to assist in the planning of strategies for strengthening surgical care systems. Cross-sectional survey. Health facilities in all 3 administrative zones of Somalia; northwest Somalia (NWS), known as Somaliland; northeast Somalia (NES), known as Puntland; and south/central Somalia (SCS). 14 health facilities. The WHO Tool for Situational Analysis to Assess Emergency and Essential Surgical Care was employed to capture a health facility's capacity to deliver surgical and anaesthesia services by investigating four categories of data: infrastructure, human resources, interventions available and equipment. The 14 facilities surveyed in Somalia represent 10 of the 18 districts throughout the country. The facilities serve an average patient population of 331 250 people, and 12 of the 14 identify as hospitals. While major surgical procedures were provided at many facilities (caesarean section, laparotomy, appendicectomy, etc), only 22% had fully available oxygen access, 50% fully available electricity and less than 30% had any management guidelines for emergency and surgical care. Furthermore, only 36% were able to provide general anaesthesia inhalation due to lack of skills, supplies and equipment. Basic supplies for airway management and the prevention of infection transmission were severely lacking in most facilities. According to the results of the WHO Tool for Situational Analysis to Assess Emergency and Essential Surgical Care survey, there exist significant gaps in the capacity of emergency and essential surgical services in Somalia including inadequacies in essential equipment, service provision and infrastructure. The information provided by the WHO tool can serve as a basis for evidence-based decisions on country-level policy regarding the allocation of resources and provision of emergency and essential

  20. Safety test facilities - status, needs, future directions

    International Nuclear Information System (INIS)

    Heusener, G.; Cogne, F.

    1979-08-01

    A survey is given of the in-pile programs which are presently or in the near future being performed in the DeBeNe-area and in France. Only those in-pile programs are considered which are dealing with severe accidents that might lead to disruption of major parts of the core. By comparing the needs with the goals of the present programs points are identified which are not sufficiently well covered up till now. The future procedure is described: the existing facilities will be used to the largest possible extent. Whenever it is necessary, upgrading and improvement will be foreseen. Studies of a Test Facility allowing the transient testing of large pin bundles should be continued. The construction of such a facility in Europe in the near future however seems premature

  1. Quality Assurance for Operation of Nuclear Facilities

    International Nuclear Information System (INIS)

    Park, C. G.; Kwon, H. I.; Kim, K. H.; Oh, Y. W.; Lee, Y. G.; Ha, J. H.; Lim, N. J.

    2008-12-01

    This report describes QA activities performed within 'Quality Assurance for Nuclear facility project' and results thereof. Efforts were made to maintain and improve quality system of nuclear facilities. Varification activities whether quality system was implemented in compliance with requirements. QA department assisted KOLAS accredited testing and calibration laboratories, ISO 9001 quality system, establishment of QA programs for R and D, and carried out reviews and surveys for development of quality assurance technologies. Major items of this report are as follows : - Development and Improvement of QA Programs - QA Activities - Assessment of Effectiveness and Adequacy for QA Programs

  2. The ZTF Bright Transient Survey

    Science.gov (United States)

    Fremling, C.; Sharma, Y.; Kulkarni, S. R.; Miller, A. A.; Taggart, K.; Perley, D. A.; Gooba, A.

    2018-06-01

    As a supplement to the Zwicky Transient Facility (ZTF; ATel #11266) public alerts (ATel #11685) we plan to report (following ATel #11615) bright probable supernovae identified in the raw alert stream from the ZTF Northern Sky Survey ("Celestial Cinematography"; see Bellm & Kulkarni, 2017, Nature Astronomy 1, 71) to the Transient Name Server (https://wis-tns.weizmann.ac.il) on a daily basis; the ZTF Bright Transient Survey (BTS; see Kulkarni et al., 2018; arXiv:1710.04223).

  3. A Survey of Structural Design of Diagnostic X-ray Imaging Facilities and Compliance to Shielding Design Goals in a Limited Resource Setting

    Directory of Open Access Journals (Sweden)

    Flavious B. Nkubli

    2017-11-01

    Full Text Available Purpose: To survey structural designs of x-ray rooms and compliance to shielding design goals of three x-ray imaging facilities. Methods and Materials: The survey was conducted in three radiodiagnostic centers in South East Nigeria, labeled X, Y and Z for anonymity. A stretchable non-elastic meter rule was used to measure x-ray room dimensions. A Vernier caliper was used to measure lead thickness while a calibrated digital survey meter Radalert 100x was used for radiation survey of controlled and uncontrolled areas. Simple statistical tools such as mean and standard deviation were used for analysis with the aid of Microsoft Excel version 2007. Results: Center X had a room dimension of 2.4 m × 2.1 m, Center Y had an x-ray room dimension of 3.6 m × 3.3 m, and Center Z had two x-ray rooms with identical dimensions of 6.3 m × 3.6 m. Measured exit radiation doses for controlled areas in all the centers were: 0.00152 mSv/wk; 0.00496 mSv/wk; 0.00168 mSv/wk; 0.00224 mSv/wk respectively. Lead was the common shielding material used. Conclusion: Based on the parameters studied, Center Z had the ideal room size and layout. Relative distances from the x-ray tubes to the nearest walls were not optimized in all the centers except in Center Z. Measured exit doses were within recommended limits except in Center Y. The location of the control consoles and measured doses were appropriate and within recommended design goals.

  4. Survey of brachytherapy practice in the United States: a report of the Clinical Research Committee of the American Endocurietherapy Society.

    Science.gov (United States)

    Nag, S; Owen, J B; Farnan, N; Pajak, T F; Martinez, A; Porter, A; Blasko, J; Harrison, L B

    1995-01-01

    To obtain reliable data on the extent of the brachytherapy practice in the United States by conducting a comprehensive survey of all facilities. The Clinical Research Committee of the AES surveyed all 1321 radiation oncology facilities identified in the Patterns of Care Study (PCS) of the American College of Radiology (ACR). Multiple mailings and follow-up were made to obtain a high response rate. Survey responders and nonresponders were compared using chi-square tests. Summary statistics were reported. Of the 1321 facilities, 1054 responded (80%). Hospital-based and larger facilities had a statistically significant higher rate of response. Brachytherapy was being performed at 819 facilities (the median number of procedures = 21-50). Two hundred and two facilities did no brachytherapy. The common isotopes used were 137Cs (705 facilities), 192Ir (585 facilities), 125I (236 facilities), and 131I (194 facilities). The common brachytherapy techniques used were intracavitary (751 facilities), interstitial (536 facilities), intraluminal (310 facilities), and plaques (148 facilities). Remote afterloaded brachytherapy was used at 205 centers as follows: high dose rate (HDR) (164), medium dose rate (MDR) (5), and low dose rate (LDR) (36). Computerized dosimetry was most commonly used (790 facilities), followed by Patterson-Parker (104 facilities) and Quimby (72 facilities). The common sites treated were cervix (701 facilities), endometrium (565 facilities), head and neck (354 facilities), and lung (344 facilities). Data regarding brachytherapy practice has been obtained from a large percentage (80%) of all facilities in the United States. The majority (78-81%) of radiation oncology facilities perform brachytherapy; however, its use is restricted to gynecological implants in many of these centers. The results from this survey will be used to develop a pattern of care study and data registry in brachytherapy.

  5. Nationwide survey of cobalt-60 teletherapy. Final report

    International Nuclear Information System (INIS)

    Thompson, D.L.; Kearly, F.E.; Wyckoff, H.O.; Gitlin, J.N.; Reffit, E.B.; Shangold, E.J.

    1980-08-01

    The Bureau of Radiological Health and the National Bureau of Standards conducted a nationwide survey of cobalt-60 teletherapy facilities to determine their accuracy in delivery of a prescribed dose to a phantom. Participation was obtained from 684 respondents or 75 percent of US facilities. For each cobalt-60 unit the average dose recorded on five dosimeters was within 5 percent of the prescribed value for 83 percent of the respondents and only exceeded a 10 percent difference for 3 percent of the respondents. Sufficient information for reconstruction of dose calculations was available for 87 percent of the participating facilities. Of these reconstructed calculations, 56 percent were within 1 percent of the prescribed dose of 300 rads. The analysis of data from the survey showed that better performance were related to a number of factors. Among these were expressing the machine calibration in terms of dose rate, performing the machine calibration on an annual basis, and correcting for source decay on a monthly basis. Larger facilities achieved better results than smaller facilities when calculating the absorbed dose rate. Also, each 4 machine characteristics (isocentric mounting, short exposure time, high normalized output, and long treatment distance) were related to better performance with regard to both dosimeter readings and calculated doses. Larger facilities were more likely to be using a cobalt-60 unit having those characteristics

  6. Nuclear energy center site survey reactor plant considerations

    International Nuclear Information System (INIS)

    1976-05-01

    The Energy Reorganization Act of 1974 required the Nuclear Regulatory Commission (NRC) to make a nuclear energy center site survey (NECSS). Background information for the NECSS report was developed in a series of tasks which include: socioeconomic inpacts; environmental impact (reactor facilities); emergency response capability (reactor facilities); aging of nuclear energy centers; and dry cooled nuclear energy centers

  7. Household trends in access to improved water sources and sanitation facilities in Vietnam and associated factors: findings from the Multiple Indicator Cluster Surveys, 2000–2011

    Science.gov (United States)

    Tuyet-Hanh, Tran Thi; Lee, Jong-Koo; Oh, Juhwan; Van Minh, Hoang; Ou Lee, Chul; Hoan, Le Thi; Nam, You-Seon; Long, Tran Khanh

    2016-01-01

    Background Despite progress made by the Millennium Development Goal (MDG) number 7.C, Vietnam still faces challenges with regard to the provision of access to safe drinking water and basic sanitation. Objective This paper describes household trends in access to improved water sources and sanitation facilities separately, and analyses factors associated with access to improved water sources and sanitation facilities in combination. Design Secondary data from the Vietnam Multiple Indicator Cluster Survey in 2000, 2006, and 2011 were analyzed. Descriptive statistics and tests of significance describe trends over time in access to water and sanitation by location, demographic and socio-economic factors. Binary logistic regressions (2000, 2006, and 2011) describe associations between access to water and sanitation, and geographic, demographic, and socio-economic factors. Results There have been some outstanding developments in access to improved water sources and sanitation facilities from 2000 to 2011. In 2011, the proportion of households with access to improved water sources and sanitation facilities reached 90% and 77%, respectively, meeting the 2015 MDG targets for safe drinking water and basic sanitation set at 88% and 75%, respectively. However, despite these achievements, in 2011, only 74% of households overall had access to combined improved drinking water and sanitation facilities. There were also stark differences between regions. In 2011, only 47% of households had access to both improved water and sanitation facilities in the Mekong River Delta compared with 94% in the Red River Delta. In 2011, households in urban compared to rural areas were more than twice as likely (odds ratio [OR]: 2.2; 95% confidence interval [CI]: 1.9–2.5) to have access to improved water and sanitation facilities in combination, and households in the highest compared with the lowest wealth quintile were over 40 times more likely (OR: 42.3; 95% CI: 29.8–60.0). Conclusions More

  8. Household trends in access to improved water sources and sanitation facilities in Vietnam and associated factors: findings from the Multiple Indicator Cluster Surveys, 2000–2011

    Directory of Open Access Journals (Sweden)

    Tran Thi Tuyet-Hanh

    2016-02-01

    Full Text Available Background: Despite progress made by the Millennium Development Goal (MDG number 7.C, Vietnam still faces challenges with regard to the provision of access to safe drinking water and basic sanitation. Objective: This paper describes household trends in access to improved water sources and sanitation facilities separately, and analyses factors associated with access to improved water sources and sanitation facilities in combination. Design: Secondary data from the Vietnam Multiple Indicator Cluster Survey in 2000, 2006, and 2011 were analyzed. Descriptive statistics and tests of significance describe trends over time in access to water and sanitation by location, demographic and socio-economic factors. Binary logistic regressions (2000, 2006, and 2011 describe associations between access to water and sanitation, and geographic, demographic, and socio-economic factors. Results: There have been some outstanding developments in access to improved water sources and sanitation facilities from 2000 to 2011. In 2011, the proportion of households with access to improved water sources and sanitation facilities reached 90% and 77%, respectively, meeting the 2015 MDG targets for safe drinking water and basic sanitation set at 88% and 75%, respectively. However, despite these achievements, in 2011, only 74% of households overall had access to combined improved drinking water and sanitation facilities. There were also stark differences between regions. In 2011, only 47% of households had access to both improved water and sanitation facilities in the Mekong River Delta compared with 94% in the Red River Delta. In 2011, households in urban compared to rural areas were more than twice as likely (odds ratio [OR]: 2.2; 95% confidence interval [CI]: 1.9–2.5 to have access to improved water and sanitation facilities in combination, and households in the highest compared with the lowest wealth quintile were over 40 times more likely (OR: 42.3; 95% CI: 29.8–60

  9. Environmental Survey Report for the ETTP: Environmental Management Waste Management Facility (EMWMF) Haul Road Corridor, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, M.J.

    2005-12-20

    This report summarizes the results of environmental surveys conducted within the corridor of a temporary haul road (''Haul Road'') to be constructed from East Tennessee Technology Park (ETTP) to the Environmental Management Waste Management Facility (EMWMF) located just west of the Y-12 National Security Complex (Y-12). Environmental surveys were conducted by natural resource experts at Oak Ridge National Laboratory who routinely assess the significance of various project activities on the Oak Ridge Reservation (ORR). ORNL assistance to the Haul Road Project included environmental assessments necessary to determine the best route for minimizing impacts to sensitive resources such as wetlands or rare plants. Once the final route was chosen, environmental surveys were conducted within the corridor to evaluate the impacts to sensitive resources that could not be avoided. The final Haul Road route follows established roads and a power-line corridor to the extent possible (Fig. 1). Detailed explanation regarding the purpose of the Haul Road and the regulatory context associated with its construction is provided in at least two major documents and consequently is not presented here: (1) Explanation of Significant Differences for the Record of Decision for the Disposal of Oak Ridge Reservation Comprehensive Environmental Response, Compensation, and Liability Act of 1980 Waste, Oak Ridge, Tennessee (January 2005, DOE/OR/01-2194&D2), and (2) Environmental Monitoring Plan for The ETTP to EMWMF Haul Road for the Disposal of Oak Ridge Reservation Comprehensive Environmental Response, Compensation, and Liability Act of 1980 Waste, Oak Ridge, Tennessee (April 2005, BJC/OR-2152). The focus of this report is a description of the sensitive resources to be impacted by Haul Road construction. Following a short description of the methods used for the environmental surveys, results and observations are presented in the following subsections: (1) General description

  10. An international survey of cleaning and disinfection practices in the healthcare environment.

    Science.gov (United States)

    Kenters, Nikki; Gottlieb, Thomas; Hopman, Joost; Mehtar, Shaheen; Schweizer, Marin L; Tartari, Ermira; Huijskens, E G W; Voss, Andreas

    2018-05-14

    Antimicrobial resistance has become an urgent global health priority. Basic hygiene practices and cleaning and disinfection of the hospital environment are key in preventing pathogen cross-transmission. To our knowledge no studies have assessed the worldwide differences in cleaning and disinfection practices in healthcare facilities. The electronic survey described here was developed in order to evaluate differences in healthcare facility cleaning practices around the world. The International Society of Antimicrobial Chemotherapy (ISAC, formerly ISC), Infection Prevention and Control work group developed a survey with 30 multiple-choice questions. The questions were designed to assess the current cleaning practices in healthcare settings around the world. A total of 110 healthcare professionals, representing 23 countries participated in the online survey. In 96% of the facilities a written cleaning policy was present. Training of cleaning staff occurred in 70% of the facilities at the start of employment. Cleaning practices and monitoring of these practices varied. In summary, the survey enabled assessment and recognition of widely differing global practices in approaches to environmental cleaning and disinfection. Development of guideline recommendations for cleaning and disinfection could improve practices and set minimum standards worldwide. Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  11. Barriers and commitment of facilities management profession to the sustainability agenda

    Energy Technology Data Exchange (ETDEWEB)

    Elmualim, Abbas; Shockley, Daniel [ICRC, The School of Construction Management and Engineering University of Reading, Whiteknights, PO BOX 219 (United Kingdom); Valle, Roberto [ICRC, The School of Construction Management and Engineering University of Reading, Whiteknights, PO BOX 219 (United Kingdom); British Institute of Facilities Management (BIFM) (United Kingdom); Ludlow, Gordon [British Institute of Facilities Management (BIFM) (United Kingdom); Shah, Sunil [Jacobs, Reading (United Kingdom)

    2010-01-15

    The practice of sustainable facilities management (FM) is rapidly evolving with the increasing interest in the discourse of sustainable development. This paper examines a recent survey of the experiences of facilities managers in the rapidly growing and evolving industry in regard to the barriers and their commitment to the sustainability agenda. The survey results show that time constraints, lack of knowledge and lack of senior management commitment are the main barriers for the implementation of consistent and comprehensive sustainable FM policy and practice. The paper concludes that the diversity of the FM role and the traditional undervaluation of the contribution it makes to the success of organisations are partially responsible for lack of success in achieving sustainable facilities. The overwhelming barrier for sustainable FM practice is the lack of understanding, focus and commitment of senior executives in appreciating the opportunities, threats and need for strategic leadership and direction in driving essential change, and hence further the sustainability agenda. (author)

  12. Transitioning to a New Facility: The Crucial Role of Employee Engagement.

    Science.gov (United States)

    Slosberg, Meredith; Nejati, Adeleh; Evans, Jennie; Nanda, Upali

    Transitioning to a new facility can be challenging for employees and detrimental to operations. A key aspect of the transition is employee understanding of, and involvement in, the design of the new facility. The literature lacks a comprehensive study of the impact of change engagement throughout the design, construction, and activation of a project as well as how that can affect perceptions, expectations, and, eventually, satisfaction of employees. The purpose of this research was to examine employee perceptions and satisfaction throughout a hospital design, construction, and activation process. Three pulse-point surveys were administered throughout the transition of a children's hospital emergency department and neonatal intensive care unit to a new facility. We also administered a postoccupancy survey 3 months after the move into the new facility. We received 544 responses and analyzed them to assess the relationship between involvement in design or change engagement initiatives and overall perceptions. The results revealed a strong relationship between employee engagement and their level of preparedness to move, readiness to adapt, and satisfaction. Early involvement in the design of a facility or new processes can significantly affect staff preparedness and readiness to adapt as well as employees' overall satisfaction with the building after occupancy. In addition, our findings suggest that keeping a finger on the pulse of employee perceptions and expectations throughout the design, construction, and activation phase is critical to employee preparedness and satisfaction in transitioning to a new facility.

  13. Surplus Facilities Management Program. Post-remedial-action survey report for SNAP-8 Experimental Reactor Facility, Building 010 site, Santa Susana Field Laboratories, Rockwell International, Ventura County, California

    International Nuclear Information System (INIS)

    Wynveen, R.A.; Smith, W.H.; Sholeen, C.M.; Mayes, C.B.; Justus, A.L.; Flynn, K.F.

    1984-04-01

    Based on the results of the radiological assessment, the Argonne National Laboratory Radiological Survey Group arrived at the following conclusions: (1) soil contaminated with the radionuclides 60 Co and 152 Eu of undetermined origin was detected in the southwest quadrant of the Building 010 site. 60 Co was also detected in one environmental sample taken from an area northwest of the site and in a borehole sample taken from the area that previously held the radioactive gas hold-up tanks. Uranium was detected in soil from a hole in the center of the building site and in a second hole southwest of the building site. In all cases, the radionuclide levels encountered in the soil were well below the criteria set by DOE for this site; and (2) the direct instrument readings at the surface of the site were probably the result of natural radiation (terrestrial and celestial), as well as shine from the material being stored at the nearby RMDF facility. There was no evidence that the contaminated soil under the asphalt pad contributed detectable levels to the total background readings

  14. Aerial radiological survey of the Argonne National Laboratory and surrounding area, Argonne, Illinois. Date of survey: May 1977

    International Nuclear Information System (INIS)

    1982-12-01

    An aerial radiological survey was conducted over the facilities of the Argonne National Laboratory in Argonne, Illinois, on 2 to 13 May 1977. The survey was flown at an altitude of 46 m by a helicopter containing 20 sodium iodide detectors. The line spacing was also 46 m. Enhanced gamma exposure rate levels, which could be attributed to Argonne operations, were observed at many locations

  15. Adverse event reporting in Czech long-term care facilities.

    Science.gov (United States)

    Hěib, Zdenřk; Vychytil, Pavel; Marx, David

    2013-04-01

    To describe adverse event reporting processes in long-term care facilities in the Czech Republic. Prospective cohort study involving a written questionnaire followed by in-person structured interviews with selected respondents. Long-term care facilities located in the Czech Republic. Staff of 111 long-term care facilities (87% of long-term care facilities in the Czech Republic). None. Sixty-three percent of long-term health-care facilities in the Czech Republic have adverse event-reporting processes already established, but these were frequently very immature programs sometimes consisting only of paper recording of incidents. Compared to questionnaire responses, in-person interview responses only partially tended to confirm the results of the written survey. Twenty-one facilities (33%) had at most 1 unconfirmed response, 31 facilities (49%) had 2 or 3 unconfirmed responses and the remaining 11 facilities (17%) had 4 or more unconfirmed responses. In-person interviews suggest that use of a written questionnaire to assess the adverse event-reporting process may have limited validity. Staff of the facilities we studied expressed an understanding of the importance of adverse event reporting and prevention, but interviews also suggested a lack of knowledge necessary for establishing a good institutional reporting system in long-term care.

  16. Survey on radionuclide producing using cyclotron method in Malaysia

    International Nuclear Information System (INIS)

    Mohd Fadli Mohammad Noh

    2008-01-01

    This research discuss about basic design and systems of medical cyclotron that Malaysia currently have, its applications in radionuclide production and upcoming technologies of cyclotron. Surveys have been carried out on cyclotron facilities at Hospital Putrajaya and Wijaya International Medical Center, WIMC as well as reactor facility at Malaysia Nuclear Agency. The sources in this research also involves on-line and library searches. Information obtained are recorded, categorized, synthesized and discussed. systems of cyclotron of Hospital Putrajaya are further discussed in details. Based from the surveys carried out, it is found out that cyclotron facilities both in Hospital Putrajaya and WIMC only produce ( 18 F)FDG with radioactivity of 18 F produced in 2007 are 16479 mCi and 92546 mCi respectively. Survey also revealed that radioisotope production at Nuclear Malaysia has had its operation been ceased. A new radiopharmaceutical, namely CHOL is suggested to be synthesized by both facilities as a new PET tracer. Latest developments concerning technologies of cyclotron as well as other accelerators such as laser for future medical accelerator, prospect of boron neutron capture and the potential of hadron therapy in Malaysia are discussed here. Radioisotope production in Malaysia is expected to keep booming in future due to increase in usage of PET techniques and the construction of more compact, easy to handle and less costly cyclotrons. (author)

  17. Aerial infrared monitoring for nuclear fuel cycle facilities in Ukraine

    International Nuclear Information System (INIS)

    Stankevich, S.A.; Dudar, T.V.; Kovalenko, G.D.; Kartashov, V.V.

    2015-01-01

    The scientific research overall objective is rapid express detection and preliminary identification of pre-accidental conditions at nuclear fuel cycle facilities. We consider development of a miniature unmanned aerial vehicle equipped with high-precision infrared spectroradiometer able to detect remotely internal warming up of hazardous facilities by its thermal infrared radiation. The possibility of remote monitoring using unmanned aerial vehicle is considered at the example of the dry spent fuel storage facility of the Zaporizhzhya Nuclear Power Plant. Infrared remote monitoring is supposed to present additional information on the monitored facilities based on different physical principles rather than those currently in use. Models and specifications towards up-to-date samples of infrared surveying equipment and its small-sized unmanned vehicles are presented in the paper.

  18. Wastewater treatment facilities: Energy efficient improvements and cogeneration

    International Nuclear Information System (INIS)

    Kunkle, R.; Gray, R.; Delzel, D.

    1992-10-01

    The Washington State Energy Office (WSEO) has worked with both the Bonneville Power Administration (BPA) and the US Department of Energy to provide technical and financial assistance to local governments. Based on a recent study conducted by Ecotope for WSEO, local governments spend an estimated $45 million on utility bills statewide. Water and wastewater facilities account for almost a third of this cost. As a result, WSEO decided to focus its efforts on the energy intensive water and wastewater sector. The ultimate goal of this project was to develop mechanisms to incorporate energy efficiency improvements into wastewater treatment facilities in retrofits and during upgrades, remodels, and new construction. Project activities included the following: The review of the existing regulatory environment for treatment system construction, A summary of financing options for efficiency improvements in treatment facilities, A literature review of energy efficiency opportunities in treatment plants, Survey and site visits to characterize existing facilities in Washington State, Estimates of the energy efficiency and cogeneration potential in the sector, and A case study to illustrate the implementation of an efficiency improvement in a treatment facility

  19. Consolidating parenting skills in children’s facilities

    Directory of Open Access Journals (Sweden)

    Ivana Dokoupilová

    2016-12-01

    Full Text Available The content of this paper is a report on activities in children’s facilities and their ability to influence parenting skills in terms of institutional childcare at an early age. Children’s facilities (infant homes, children’s homes and children’s centres provide comprehensive care for children and parents in cases where, for various reasons, a child’s all-round development is disrupted or their life is in danger. The main purpose of these facilities is to provide adequate childcare as well as to support families when restoring basic functions. On the basis of a survey conducted in children’s facilities, the most frequent difficulties in exercising parenting skills are identified, and subsequently, information on the extent to which children’s facilities contribute to the development of parenting skills and help in the rehabilitation of a family is outlined.

  20. Environmental survey near a decommissioning nuclear facility: example of tritium monitoring in the terrestrial environment of Creys-Malville - Environmental survey near a nuclear facility undergoing decommissioning: example of tritium monitoring in the terrestrial environment of Creys-Malville

    Energy Technology Data Exchange (ETDEWEB)

    Boyer, C.; Gontier, G.; Chauveau, J.L. [EDF CIDEN, Division Environnement, 154 Avenue Thiers, 69458 Lyon (France); Pourcelot, L.; Roussel-Debet, S.; Cossonnet, P.C. [IRSN, LERCM Cadarache and LMRE Orsay (France); Jean-Baptiste, P. [LSCE, UMR 1572-CEA/CNRS/UVQS, 91198 Gif sur Yvette (France)

    2014-07-01

    As part of the regulatory environmental monitoring around its nuclear power plants (NPP) in France, EDF carries out more than 40.000 measurements of radionuclides in the environment every year. In addition, EDF performs more detailed radioecological surveys on all of its sites. The purposes of these surveys are: 1/ to control that radioactive discharge limits prescribed by the regulatory authority are respected, 2/ to monitor the environment of the NPPs to verify normal plant operation and to detect all possible failures in power station operation at an early stage and 3/ to establish if there is any increase of radionuclides of anthropogenic origin in the environment and to determine whether this build-up can be attributed to plant operations. Radioecological surveys are conducted in the environment surrounding each of EDF's NPPs. Samples are collected in surrounding ecosystems (terrestrial and aquatic) where the radioactive releases are discharged (liquid and gaseous discharges). These surveys results enable the examination of the spatial distribution and temporal variability of radionuclide activity in the environment throughout the reactors life, from the first fuel load to the decommissioning of the plant. The results from this monitoring have shown that EDF's nuclear power plants have only a minor effect on radionuclide levels in the environment. These results highlight the efficiency of EDF's efforts to minimise its impacts on the environment via an efficient waste management system and high operating standards of its plants. In particular, tritium is subject to special monitoring for more than 30 years; concentrations of free tritium and organically bound tritium in major environmental compartments are therefore well-known in the vicinity of French NPPs. At the end of a reactor's life, EDF has collected a large amount of reference data before decommissioning operations start. During these operations, EDF pursue the radioecological survey

  1. Description of the U.S. Geological Survey's water-quality sampling and water-level monitoring program at the Hallam Nuclear Facility, June through September 1996

    International Nuclear Information System (INIS)

    1997-01-01

    A water-quality and water-level program of the US Department of Energy (USDOE) in cooperation with the US Geological Survey (USGS) was re-established in June 1996 to develop six new USDOE observation wells, collect one set of water-quality samples from 17 of the 19 USDOE observation wells, and take monthly water-level measurements for a 3-month period in all 19 USDOE observation wells at the Hallam Nuclear Facility, Hallam, Nebraska. Thirteen of the observation wells were installed by HWS Consulting Group, Inc., in June 1993 and the remaining six were installed by Applied Research Associates in August 1995

  2. Prevalance rate of low-dose CT lung cancer screening. Results of a questionnaire survey of member facilities of Japan society of ningen dock with special concerns regarding the actual status and disincentives for implementing such screening

    International Nuclear Information System (INIS)

    Takizawa, Hirotaka

    2012-01-01

    We conducted a survey of member facilities of the Japan Society of Ningen Dock to elucidate the actual status of chest computed tomography (CT) screening and the reasons for not being able to change to low-dose CT. We sent a questionnaire consisting of 9 items to 531 member facilities in July 2010, response by facsimile to obtain an analysis. The prevalence rate of low-dose CT lung cancer screening slightly increased to 35% in comparison with the former survey done in November 2008. Some facilities indicated some shift in tube current to a lower range even though this was insufficient to meet the definition of low-dose CT. This reflects their thinking of ''Even with knowledge, there is strong hesitation to change to low-dose CT''. Among the reasons why they did not change to low-dose CT, a priority for high quality images was the top reason among problems of devices and performance. Informed consent was not yet adequate. It is necessary for manufactures to develop better technology to improve the image quality of low-dose CT and to report enough information to clinicians. On the medical side, perception of the necessity for appropriate reduction of radiation dose and the decision to move to low-dose CT would be of crucial significance for facility heads as well as radiologists and technicians. (author)

  3. ORNL shielded facilities capable of remote handling of highly radioactive beta--gamma emitting materials

    International Nuclear Information System (INIS)

    Whitson, W.R.

    1977-09-01

    A survey of ORNL facilities having adequate shielding and containment for the remote handling of experimental quantities of highly radioactive beta-gamma emitting materials is summarized. Portions of the detailed descriptions of these facilities previously published in ORNL/TM-1268 are still valid and are repeated

  4. Environmental Protection Agency (EPA) Facility Registry Service (FRS) Wastewater Treatment Plants

    Data.gov (United States)

    Department of Homeland Security — This GIS dataset contains data on wastewater treatment plants, based on EPA's Facility Registry Service (FRS) and NPDES, along with Clean Watersheds Needs Survey...

  5. High prevalence of cesarean section births in private sector health facilities- analysis of district level household survey-4 (DLHS-4) of India.

    Science.gov (United States)

    Singh, Priyanka; Hashmi, Gulfam; Swain, Prafulla Kumar

    2018-05-10

    Worldwide rising cesarean section (CS) births is an issue of concern. In India, with increase in institutional deliveries there has also been an increase in cesarean section births. Aim of the study is to quantify the prevalence of cesarean section births in public and private health facility, and also to determine the factors associated with cesarean section births. We analyzed data from district level household survey data 4 (DLHS-4) combined individual level dataset for 19 states/UTs of India comprising 24,398 deliveries resulting in 22,111 live births for year 2011. The percentages and Chi-square has been computed for the select variables viz. Socio demographic, maternal, antenatal care and delivery related based on type of births (CS Vs normal births). The multiple logistic regression model has been used to identify the potential risk factors associated with CS births. Of 22,111 live birth analyzed 49.2% were delivered at public sector, 31.9% at private sector and 18.9% were home deliveries. Prevalence of CS births were 13.7% (95% CI; 13.0- 14.3%) and 37.9% (95% CI; 36.7- 39.0%) in the public and private sectors, respectively. Higher odds of CS births were observed with- delivery at private health facility (OR 3.79; 95% C.I 3.06-4.72), urban residence (OR 1.15; 95% C.I 1.00- 1.35), first delivery after 35 years of maternal age (OR 5.5; 95% C.I 1.85- 16.4), hypertension in pregnancy (OR 1.32; 95% C.I 1.06- 1.65) and breach presentation (OR 2.37; 95% C.I. 1.63- 3.43). Our findings shows that CS births are nearly three times more in private as compared to public sector health facilities.The higher rates of CS births, especially in private sector, not only increase the cost of care but may pose unnecessary risks to women (when there is no indications for CS). The government of India need to take measures to strengthen existing public health facilities as well as ensure that cesarean sections are performed based upon medical indications in both public and private

  6. Management of Tracheostomy: A Survey of Dutch Intensive Care Units

    NARCIS (Netherlands)

    Veelo, Denise P.; Schultz, Marcus J.; Phoa, Kai Y. N.; Dongelmans, Dave A.; Binnekade, Jan M.; Spronk, Peter E.

    2008-01-01

    OBJECTIVE: To determine tracheostomy-management practices in Dutch intensive care units (ICUs) and post-ICU step-down facilities. METHODS: We surveyed the physician medical directors of all Dutch nonpediatric ICUs that have : 5 beds suitable for mechanical ventilation. The survey asked for

  7. Environmental Survey preliminary report, Lawrence Berkeley Laboratory, Berkeley, California

    International Nuclear Information System (INIS)

    1988-07-01

    The purpose of this report is to present the preliminary findings made during the Environmental Survey, February 22--29, 1988, at the US Department of Energy (DOE) Lawrence Berkeley Laboratory (LBL) in Berkeley, California. The University of California operates the LBL facility for DOE. The LBL Survey is part of the larger DOE-wide Environmental Survey announced by Secretary John S. Herrington on September 18, 1985. The purpose of this effort is to identify, via ''no fault'' baseline Surveys, existing environmental problems and areas of environmental risk at DOE facilities, and to rank them on a DOE wide basis. This ranking will enable DOE to more effectively establish priorities for addressing environmental problems and allocate the resources necessary to correct them. Because the Survey is ''no fault'' and is not an ''audit,'' it is not designed to identify specific isolated incidents of noncompliance or to analyze environmental management practices. Such incidents and/or management practices will, however, be used in the Survey as a means of identifying existing and potential environmental problems. The LBL Survey was conducted by a multidisciplinary team of technical specialists headed and managed by a Team Leader and Assistant Team Leader from DOE's Office of Environmental Audit. A complete list of the LBL Survey participants and their affiliations is provided in Appendix A. 80 refs., 27 figs., 37 tabs

  8. Environmental Survey preliminary report, Lawrence Berkeley Laboratory, Berkeley, California

    Energy Technology Data Exchange (ETDEWEB)

    1988-07-01

    The purpose of this report is to present the preliminary findings made during the Environmental Survey, February 22--29, 1988, at the US Department of Energy (DOE) Lawrence Berkeley Laboratory (LBL) in Berkeley, California. The University of California operates the LBL facility for DOE. The LBL Survey is part of the larger DOE-wide Environmental Survey announced by Secretary John S. Herrington on September 18, 1985. The purpose of this effort is to identify, via no fault'' baseline Surveys, existing environmental problems and areas of environmental risk at DOE facilities, and to rank them on a DOE wide basis. This ranking will enable DOE to more effectively establish priorities for addressing environmental problems and allocate the resources necessary to correct them. Because the Survey is no fault'' and is not an audit,'' it is not designed to identify specific isolated incidents of noncompliance or to analyze environmental management practices. Such incidents and/or management practices will, however, be used in the Survey as a means of identifying existing and potential environmental problems. The LBL Survey was conducted by a multidisciplinary team of technical specialists headed and managed by a Team Leader and Assistant Team Leader from DOE's Office of Environmental Audit. A complete list of the LBL Survey participants and their affiliations is provided in Appendix A. 80 refs., 27 figs., 37 tabs.

  9. Decommissioning of nuclear facilities using current criteria

    International Nuclear Information System (INIS)

    Shum, E.Y.; Swift, J.J.; Malaro, J.C.

    1991-01-01

    When a licensed nuclear facility ceases operation, the US Nuclear Regulatory Commission (NRC) is responsible for ensuring that the facility and its site are decontaminated to an acceptable level so that it is safe to release that facility and site for unrestricted public use. Currently, the NRC is developing decommissioning criteria based on reducing public doses from residual contamination in soils and structures at sites released for unrestricted use to as low as is reasonably achievable (ALARA). Plans are to quantify ALARA in terms of an annual total effective dose equivalent (TEDE) to an average member of the most highly exposed population group. The NRC is working on a regulatory guidance document to provide a technical basis for translating residual contamination levels to annual dose levels. Another regulatory guide is being developed to provide guidance to the licensee on how to conduct radiological surveys to demonstration compliance with the NRC decommissioning criteria. The methods and approaches used in these regulatory guides on the decommissioning of a nuclear facility are discussed in the paper

  10. Status of physical protection systems of nuclear facilities; survey report

    International Nuclear Information System (INIS)

    Hwang, In Koo; Kwack, Eun Ho; Ahn, Jin Soo; Lee, Hyun Chul; Kim, Jung Soo

    2002-02-01

    This report presents a survey on the physical protection equipment for a nuclear power plant. This survey was conducted by Korea Atomic Energy Research Institute as a part of the project, 'Development of Technologies for National Control of and Accountancy for Nuclear Material,' funded by the Ministry of Science and Technology of Korea. A physical protection system of a nuclear plant includes outer and inner fences, intrusion detection sensors, alarm generation system, illumination equipment, central monitoring and control station, entry control and management system, etc. The outermost fence indicates the boundary of the plant area and prevents a simple or unintentional intrusion. The inner fence area of each plant unit associated with intrusion detection sensors, illuminators, monitoring cameras, serves the key role for physical protection function for the nuclear plant

  11. DESIGN OF FILL AND FINISH FACILITY FOR ACTIVE PHARMACEUTICAL INGREDIENTS (API

    Directory of Open Access Journals (Sweden)

    NUUR LAILA KHAIRUDDIN

    2016-08-01

    Full Text Available Fill and finish operations continue to be one of the most heavily outsourced activities in the biopharmaceutical manufacturing market today. There are a few aspects that need to be consider in outsource activities like logistic, storage condition, facility certification and audit as regulations and standards which the manufacturer should adhere. Risk would be greater and extra care should be taken when outsource from foreign fill and finish facility. Thus, the internal aseptic fill and finish facility with audit checklist will help to minimize the risk during logistic and storage and also minimize the cost for outsource fill and finish facility. The data collections are through survey and conceptual design with simulation as the execution part.

  12. Provision of family planning services in Tanzania: a comparative analysis of public and private facilities

    NARCIS (Netherlands)

    Kakoko, D.C.; Ketting, E.; Kamazima, S.R.; Ruben, R.

    2012-01-01

    Adherence to the policy guidelines and standards is necessary for family planning services. We compared public and private facilities in terms of provision of family planning services. We analyzed data from health facility questionnaire of the 2006 Tanzania Service Provision Assessment survey, based

  13. Public computing options for individuals with cognitive impairments: survey outcomes.

    Science.gov (United States)

    Fox, Lynn Elizabeth; Sohlberg, McKay Moore; Fickas, Stephen; Lemoncello, Rik; Prideaux, Jason

    2009-09-01

    To examine availability and accessibility of public computing for individuals with cognitive impairment (CI) who reside in the USA. A telephone survey was administered as a semi-structured interview to 145 informants representing seven types of public facilities across three geographically distinct regions using a snowball sampling technique. An Internet search of wireless (Wi-Fi) hotspots supplemented the survey. Survey results showed the availability of public computer terminals and Internet hotspots was greatest in the urban sample, followed by the mid-sized and rural cities. Across seven facility types surveyed, libraries had the highest percentage of access barriers, including complex queue procedures, login and password requirements, and limited technical support. University assistive technology centres and facilities with a restricted user policy, such as brain injury centres, had the lowest incidence of access barriers. Findings suggest optimal outcomes for people with CI will result from a careful match of technology and the user that takes into account potential barriers and opportunities to computing in an individual's preferred public environments. Trends in public computing, including the emergence of widespread Wi-Fi and limited access to terminals that permit auto-launch applications, should guide development of technology designed for use in public computing environments.

  14. Verification and update of BNL mixed waste survey

    International Nuclear Information System (INIS)

    Bowerman, B.S.; Siskind, B.

    1987-01-01

    This report briefly describes attempts to verify the results of a previous survey on the amount of mixed wastes generated at various facilities during 1985. The original survey indicated some lack of understanding of current EPA regulations. This telephone survey verification indicated a better understanding of these regulations in recent months. Changes in EPA regulations and the addition of new compounds to the list of hazardous wastes are causing problems for organizations trying to comply. 7 refs

  15. Advanced physical protection systems for facilities and transportation

    International Nuclear Information System (INIS)

    Jones, O.E.

    1976-01-01

    Sandia Laboratories is developing advanced physical protection safeguards in order to improve the security of special nuclear materials, facilities, and transportation. Computer models are being used to assess the cost-effectiveness of alternative systems for protecting facilities against external attack which may include internal assistance, and against internal theft or sabotage. Physical protection elements such as admittance controls, portals and detectors, perimeter and interior intrusion alarms, fixed and remotely activated barriers, and secure communications are being evaluated, adapted, and where required, developed. New facilities safeguards concepts which involve ''control loops'' between physical protection and materials control elements are being evolved jointly between Sandia Laboratories and Los Alamos Scientific Laboratory. Special vehicles and digital communications equipment have been developed for the ERDA safe-secure transportation system. The current status and direction of these activities are surveyed

  16. Advanced physical protection systems for facilities and transportation

    International Nuclear Information System (INIS)

    Jones, O.E.

    1976-01-01

    Sandia Laboratories is developing advanced physical protection safeguards in order to improve the security of special nuclear materials, facilities, and transportation. Computer models are being used to assess the cost-effectiveness of alternative systems for protecting facilities against external attack which may include internal assistance, and against internal theft or sabotage. Physical protection elements such as admittance controls, portals and detectors, perimeter and interior intrusion alarms, fixed and remotely-activated barriers, and secure communications are being evaluated, adapted, and where required, developed. New facilities safeguards concepts which involve (control loops) between physical protection and materials control elements are being evolved jointly between Sandia Laboratories and Los Alamos Scientific Laboratory. Special vehicles and digital communications equipment have been developed for the ERDA safe-secure transportation system. The current status and direction of these activities are surveyed

  17. Waste management facility acceptance - some findings

    International Nuclear Information System (INIS)

    Sigmon, B.

    1987-01-01

    Acceptance of waste management facilities remains a significant problem, despite years of efforts to reassure potential host communities. The tangible economic benefits from jobs, taxes, and expenditures are generally small, while the intangible risks of environmental or other impacts are difficult to evaluate and understand. No magic formula for winning local acceptance has yet been found. Limited case study and survey work does suggest some pitfalls to be avoided and some directions to be pursued. Among the most significant is the importance that communities place on controlling their own destiny. Finding a meaningful role for communities in the planning and operation of waste management facilities is a challenge that would-be developers should approach with the same creativity that characterizes their technical efforts

  18. Surplus Facilities Management Program. Post remedial action survey report for the Sodium Reactor Experiment (SRE) facility, Santa Susana Field Laboratories, Rockwell International, Ventura County, California

    International Nuclear Information System (INIS)

    Wynveen, R.A.; Smith, W.H.; Sholeen, C.M.; Flynn, K.F.; Justus, A.L.

    1984-02-01

    Decontamination of the Sodium Reactor Experiment (SRE) began in 1976 and was completed in 1982. In view of the concurrent and post-remedial-action surveys, the following conclusions can be stated. All the buildings and areas included in this decommissioning project have been decontaminated to below the limits specified in the draft ANSI Standard N13.12 and the NRC Guidelines for Decontamination of Facilities and Equipment Prior to Release for Unrestricted Use or Termination of Licenses for By-Product, Source, or Special Nuclear Material, dated July 1982. Radioactive contamination was found in appropriate access points of the sanitary sewer and storm drain systems included within the boundaries of this decommissioning project. One sample indicated a 90 Sr concentration dissolved in the water of approximately half the recommended water concentration for controlled areas and approximately 15 times the recommended water concentration for uncontrolled areas as stated in DOE-5480.1 Chg. 6, Chapter XI. Therefore, the interior inaccessible surfaces of these systems must be considered contaminated in accordance with statements found in the NRC Regulatory Guidelines issued in July 1982. Effluent from the outfall of this drain system must also be considered as being potentially contaminated. 1 reference, 32 figures, 8 tables

  19. Characteristics of U.S. Mental Health Facilities That Offer Suicide Prevention Services.

    Science.gov (United States)

    Kuramoto-Crawford, S Janet; Smith, Kelley E; McKeon, Richard

    2016-01-01

    This study characterized mental health facilities that offer suicide prevention services or outcome follow-up after discharge. The study analyzed data from 8,459 U.S. mental health facilities that participated in the 2010 National Mental Health Services Survey. Logistic regression analyses were used to compare facilities that offered neither of the prevention services with those that offered both or either service. About one-fifth of mental health facilities reported offering neither suicide prevention services nor outcome follow-up. Approximately one-third offered both, 25% offered suicide prevention services only, and 21% offered only outcome follow-up after discharge. Facilities that offered neither service were less likely than facilities that offered either to offer comprehensive support services or special programs for veterans; to offer substance abuse services; and to be accredited, licensed, or certified. Further examination of facilitators and barriers in implementing suicide prevention services in mental health facilities is warranted.

  20. The 11th quality control survey for radioisotopes in vitro tests in Japan, 1989

    Energy Technology Data Exchange (ETDEWEB)

    1990-10-01

    This report presents the results of the 11th quality control nationwide survey. Of 730 facilities performing radioisotopes in vitro tests in November 1989, 422 facilities (60.5%) participated in the present survey. The following 23 items were examined: adrenocorticotropic hormone (ACTH), albumin, carbohydrate antigen 125 (CA 125), carbohydrate antigen 19-9 (CA 19-9), carcinoembryonic antigen (CEA), calcitonin, cortisol, estradiol, ferritin, free thyroxine (FT{sub 4}), follicle stimulating hormone (FSH), gastrine, cholylglycine, glucagon, insulin, anti-DNA antibody, luteinizing hormone (LH), neuron specific enolase (NSE), parathyroid hormone (PTH), squamous cell carcinoma associated antigen (SCC), thyroxine (T{sub 4}), thyroxine binding globulin (TBG), and antithyroid stimulating hormone (TSH) receptor antibody. 'Within kit variation' between facilities showed large coefficient of variation for ACTH, CA125, CEA, estradiol, ferritin, FSH, glucagon, anti-DNA antibody, LH, PTH, and TSH receptor antibody. Both 'within kit variation' and 'between kit variation' showed small coefficient of variation for cortisol, free T{sub 4}, NSE, SCC, T{sub 4}, and TBG. The present survey was characterized by using immunoradiometric assay (IRMA) and non-isotope techniques, as well as radioimmunoassay. Kits for IRMA greatly varied from facility to facility. (N.K.).

  1. Discovery of practical production processes for arylsulfur pentafluorides and their higher homologues, bis- and tris(sulfur pentafluorides: Beginning of a new era of “super-trifluoromethyl” arene chemistry and its industry

    Directory of Open Access Journals (Sweden)

    Teruo Umemoto

    2012-03-01

    Full Text Available Various arylsulfur pentafluorides, ArSF5, have long been desired in both academic and industrial areas, and ArSF5 compounds have attracted considerable interest in many areas such as medicines, agrochemicals, and other new materials, since the highly stable SF5 group is considered a “super-trifluoromethyl group” due to its significantly higher electronegativity and lipophilicity. This article describes the first practical method for the production of various arylsulfur pentafluorides and their higher homologues, bis- and tris(sulfur pentafluorides, from the corresponding diaryl disulfides or aryl thiols. The method consists of two steps: (Step 1 treatment of a diaryl disulfide or an aryl thiol with chlorine in the presence of an alkali metal fluoride, and (step 2 treatment of the resulting arylsulfur chlorotetrafluoride with a fluoride source, such as ZnF2, HF, and Sb(III/V fluorides. The intermediate arylsulfur chlorotetrafluorides were isolated by distillation or recrystallization and characterized. The aspects of these new reactions are revealed and reaction mechanisms are discussed. As the method offers considerable improvement over previous methods in cost, yield, practicality, applicability, and large-scale production, the new processes described here can be employed as the first practical methods for the economical production of various arylsulfur pentafluorides and their higher homologues, which could then open up a new era of “super-trifluoromethyl” arene chemistry and its applications in many areas.

  2. Hanford Site Near-Facility Environmental Monitoring Data Report for Calendar Year 2007- Appendix 2

    Energy Technology Data Exchange (ETDEWEB)

    Perkins, Craig J.; Dorsey, Michael; Mckinney, Stephen M.; Wilde, Justin W.; Duncan, Joanne P.

    2008-10-13

    Near-facility environmental monitoring is defined as monitoring near facilities that have the potential to discharge or have discharged, stored, or disposed of radioactive or hazardous materials. Monitoring locations are associated with nuclear facilities such as the Plutonium Finishing Plant (PFP), Canister Storage Building (CSB), and the K Basins; inactive nuclear facilities such as N Reactor and the Plutonium-Uranium Extraction (PUREX) Facility; and waste storage or disposal facilities such as burial grounds, cribs, ditches, ponds, tank farms, and trenches. Much of the monitoring consists of collecting and analyzing environmental samples and methodically surveying areas near facilities. The program is also designed to evaluate acquired analytical data, determine the effectiveness of facility effluent monitoring and controls, assess the adequacy of containment at waste disposal units, and detect and monitor unusual conditions.

  3. Study on Customer Satisfaction with Facilities Management Services in Lithuania

    Science.gov (United States)

    Lepkova, Natalija; Žūkaitė-Jefimovienė, Giedrė

    2012-12-01

    The article introduces the concept and content of facilities management (FM) services. The paper presents the concept of customer satisfaction and discusses the key factors which influence the opinions of customers and their satisfaction or dissatisfaction with the services provided. The article presents two studies: a brief survey of several FM service providers and a survey of customer satisfaction with FM services in Lithuania. The conclusions are given at the end of the article.

  4. Appalachian States Compact Low-Level Radioactive Waste management survey, 1987

    International Nuclear Information System (INIS)

    Singh, K.N.

    1989-03-01

    Since the enactment of the Low-Level Radioactive Waste Disposal Act in February 1988, the Commonwealth of Pennsylvania has undertaken major steps to develop a Low-Level Radioactive Waste (LLRW) Disposal Facility within its borders for the exclusive use of radioactive material licensees in the Appalachian States Compact. In order to adequately plan for the design and development of that facility, it is essential to obtain accurate data on LLRW being generated in the Compact. To that end, the Division of Nuclear Safety of the Pennsylvania Bureau of Radiation Protection (BRP) conducted a survey to determine volume and activity of LLRW shipped and stored in 1987 by the licensees in the Appalachian States Compact. The 1986 LLRW survey included licensees in Pennsylvania and Maryland, while surveys conducted prior to 1986 involved only Pennsylvania licensees. So this is the first survey conducted by BRP that has included all four states of the Compact

  5. Environmental Survey preliminary report, Sandia National Laboratories, Livermore, California

    International Nuclear Information System (INIS)

    1988-01-01

    This report contains the preliminary findings based on the first phase of an Environmental Survey at the Department of Energy (DOE) Sandia National Laboratories Livermore (SNLL), located at Livermore, California. The Survey is being conducted by DOE's Office of Environment, Safety and Health. The SNLL Survey is a portion of the larger, comprehensive DOE Environmental Survey encompassing all major operating facilities of DOE. The DOE Environmental Survey is one of a series of initiatives announced on September 18, 1985, by Secretary of Energy, John S. Herrington, to strengthen the environmental, safety, and health programs and activities within DOE. The purpose of the Environmental Survey is to identify, via a ''no fault'' baseline Survey of all the Department's major operating facilities, environmental problems and areas of environmental risk. The identified problem areas will be prioritized on a Department-wide basis in order of importance in 1989. The findings in this report are subject to modification based on the results from the Sampling and Analysis Phase of the Survey. The findings are also subject to modification based on comments from the Albuquerque Operations Office concerning the technical accuracy of the findings. The modified preliminary findings and any other appropriate changes will be incorporated into an Interim Report. The Interim Report will serve as the site-specific source for environmental information generated by the Survey, and ultimately as the primary source of information for the DOE-wide prioritization of environmental problems in the Survey Summary Report. 43 refs., 21 figs., 24 tabs

  6. Environmental Survey preliminary report, Sandia National Laboratories, Livermore, California

    Energy Technology Data Exchange (ETDEWEB)

    1988-01-01

    This report contains the preliminary findings based on the first phase of an Environmental Survey at the Department of Energy (DOE) Sandia National Laboratories Livermore (SNLL), located at Livermore, California. The Survey is being conducted by DOE's Office of Environment, Safety and Health. The SNLL Survey is a portion of the larger, comprehensive DOE Environmental Survey encompassing all major operating facilities of DOE. The DOE Environmental Survey is one of a series of initiatives announced on September 18, 1985, by Secretary of Energy, John S. Herrington, to strengthen the environmental, safety, and health programs and activities within DOE. The purpose of the Environmental Survey is to identify, via a no fault'' baseline Survey of all the Department's major operating facilities, environmental problems and areas of environmental risk. The identified problem areas will be prioritized on a Department-wide basis in order of importance in 1989. The findings in this report are subject to modification based on the results from the Sampling and Analysis Phase of the Survey. The findings are also subject to modification based on comments from the Albuquerque Operations Office concerning the technical accuracy of the findings. The modified preliminary findings and any other appropriate changes will be incorporated into an Interim Report. The Interim Report will serve as the site-specific source for environmental information generated by the Survey, and ultimately as the primary source of information for the DOE-wide prioritization of environmental problems in the Survey Summary Report. 43 refs., 21 figs., 24 tabs.

  7. Survey of stores for conditioned intermediate and low level wastes in Europe

    International Nuclear Information System (INIS)

    1985-10-01

    A survey has been conducted of eleven waste storage facilities in six countries. Wastes considered are intermediate and low level, conditioned for disposal. Civil engineering, handling facilities, container type, waste activities, doses to the public and to operators are considered. (author)

  8. Intensive archaeological survey of the proposed Savannah River Ecology Laboratory Conference Center and Educational Facility, Savannah River Site, Aiken County, South Carolina

    Energy Technology Data Exchange (ETDEWEB)

    Stephenson, K.; Crass, D.C.; Sassaman, K.E.

    1993-02-01

    Documented in this report are the methods and results of an intensive archaeological survey for the proposed University of Georgia Savannah River Ecology Laboratory (SREL) Conference Center and Educational Facility on the DOE Savannah River Site (SRS). Archaeological investigations conducted by the Savannah River Archaeological Research Program (SRARP) on the 70-acre project area and associated rights-of-way consisted of subsurface testing at two previously recorded sites and the discovery of one previously unrecorded site. The results show that 2 sites contain archaeological remains that may yield significant information about human occupations in the Aiken Plateau and are therefore considered eligible for nomination to the National Register of Historic Places. Adverse impacts to these sites can be mitigated through avoidance.

  9. Characteristics of administrators and quality of care in Ontario care facilities

    OpenAIRE

    Keays, Sean Charles

    2007-01-01

    This exploratory study investigated administrator and facility predictors of quality of care (QOC) in care facilities (CF). Surveys were mailed to all 602 CF administrators in Ontario; half of whom responded. Quality was measured using the last certification inspection report obtained from the Ontario Ministry of Health and Long-Term Care public report on certified CF. Quality predictors were found using multiple regression analysis. Education and experience as an administrator in current pos...

  10. Material accountancy and control practice at a research reactor facility

    International Nuclear Information System (INIS)

    Bouchard, J.; Maurel, J.J.; Tromeur, Y.

    1982-01-01

    This session surveys the regulations, organization, and accountancy practice that compose the French State System of Accountancy and Control. Practical examples are discussed showing how inventories are verified at a critical assembly facility and at a materials testing reactor

  11. An assessment of cultural values and resident-centered culture change in U.S. nursing facilities.

    Science.gov (United States)

    Banaszak-Holl, Jane; Castle, Nicholas G; Lin, Michael; Spreitzer, Gretchen

    2013-01-01

    Culture change initiatives propose to improve care by addressing the lack of managerial supports and prevalent stressful work environments in the industry; however, little is known about how culture change facilities differ from facilities in the industry that have not chosen to affiliate with the resident-centered care movements. The aim of this study was to evaluate representation of organizational culture values within a random sample of U.S. nursing home facilities using the competing values framework and to determine whether organizational values are related to membership in resident-centered culture change initiatives. We collected reports of cultural values using a well-established competing values framework instrument in a random survey of facility administrators and directors of nursing within all states. We received responses from 57% of the facilities that were mailed the survey. Directors of nursing and administrators did not differ significantly in their reports of culture and facility measures combined their responses. Nursing facilities favored market-focused cultural values on average, and developmental values, key to innovation, were the least common across all nursing homes. Approximately 17% of the facilities reported that all cultural values were strong within their facilities. Only high developmental cultural values were linked to participation in culture change initiatives. Culture change facilities were not different from non-culture change facilities in the promotion of employee focus as organizational culture, as emphasized in group culture values. Likewise, culture change facilities were also not more likely to have hierarchical or market foci than non-culture change facilities. Our results counter the argument that culture change facilities have a stronger internal employee focus than facilities more generally but do show that culture change facilities report stronger developmental cultures than non-culture change facilities, which

  12. Survey of 2014 behavioral management programs for laboratory primates in the United States.

    Science.gov (United States)

    Baker, Kate C

    2016-07-01

    The behavioral management of laboratory nonhuman primates in the United States has not been thoroughly characterized since 2003. This article presents the results of a survey behavioral management programs at 27 facilities and covering a total of 59,636 primates, 27,916 housed in indoor cages and 31,720 in group enclosures. The survey included questions regarding program structure, implementation, and methodology associated with social housing, positive reinforcement training, positive human interaction, exercise enclosures, and several categories of inanimate enrichment. The vast majority of laboratory primates are housed socially (83%). Since 2003, the proportion of indoor-housed primates reported to be housed singly has fallen considerably, from 59% to 35% in the facilities surveyed. The use of social housing remains significantly constrained by: 1) research protocol requirements, highlighting the value of closely involved IACUCs for harmonizing research and behavioral management; and 2) the unavailability of compatible social partners, underscoring the necessity of objective analysis of the methods used to foster and maintain compatibility. Positive reinforcement training appears to have expanded and is now used at all facilities responding to the survey. The use of enrichment devices has also increased in the participating facilities. For most behavioral management techniques, concerns over the possibility of negative consequences to animals are expressed most frequently for social housing and destructible enrichment, while skepticism regarding efficacy is limited almost exclusively to sensory enrichment. Behavioral management program staffing has expanded over time in the facilities surveyed, due not only to increased numbers of dedicated behavioral management technicians but also to greater involvement of animal care technicians, suggesting an increase in the integration of behavioral care into animal husbandry. Broad awareness of common practice may assist

  13. Evaluating malaria case management at public health facilities in two provinces in Angola.

    Science.gov (United States)

    Plucinski, Mateusz M; Ferreira, Manzambi; Ferreira, Carolina Miguel; Burns, Jordan; Gaparayi, Patrick; João, Lubaki; da Costa, Olinda; Gill, Parambir; Samutondo, Claudete; Quivinja, Joltim; Mbounga, Eliane; de León, Gabriel Ponce; Halsey, Eric S; Dimbu, Pedro Rafael; Fortes, Filomeno

    2017-05-03

    Malaria accounts for the largest portion of healthcare demand in Angola. A pillar of malaria control in Angola is the appropriate management of malaria illness, including testing of suspect cases with rapid diagnostic tests (RDTs) and treatment of confirmed cases with artemisinin-based combination therapy (ACT). Periodic systematic evaluations of malaria case management are recommended to measure health facility readiness and adherence to national case management guidelines. Cross-sectional health facility surveys were performed in low-transmission Huambo and high-transmission Uíge Provinces in early 2016. In each province, 45 health facilities were randomly selected from among all public health facilities stratified by level of care. Survey teams performed inventories of malaria commodities and conducted exit interviews and re-examinations, including RDT testing, of a random selection of all patients completing outpatient consultations. Key health facility readiness and case management indicators were calculated adjusting for the cluster sampling design and utilization. Availability of RDTs or microscopy on the day of the survey was 71% (54-83) in Huambo and 85% (67-94) in Uíge. At least one unit dose pack of one formulation of an ACT (usually artemether-lumefantrine) was available in 83% (66-92) of health facilities in Huambo and 79% (61-90) of health facilities in Uíge. Testing rates of suspect malaria cases in Huambo were 30% (23-38) versus 69% (53-81) in Uíge. Overall, 28% (13-49) of patients with uncomplicated malaria, as determined during the re-examination, were appropriately treated with an ACT with the correct dose in Huambo, compared to 60% (42-75) in Uíge. Incorrect case management of suspect malaria cases was associated with lack of healthcare worker training in Huambo and ACT stock-outs in Uíge. The results reveal important differences between provinces. Despite similar availability of testing and ACT, testing and treatment rates were lower in

  14. National Geochemical Survey Locations and Results for Iowa

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — The United States Geological Survey (USGS), in collaboration with other state and federal agencies, industry, and academia, is conducting a National Geochemical...

  15. Use of information technology for medication management in residential care facilities: correlates of facility characteristics.

    Science.gov (United States)

    Bhuyan, Soumitra S; Chandak, Aastha; Powell, M Paige; Kim, Jungyoon; Shiyanbola, Olayinka; Zhu, He; Shiyanbola, Oyewale

    2015-06-01

    The effectiveness of information technology in resolving medication problems has been well documented. Long-term care settings such as residential care facilities (RCFs) may see the benefits of using such technologies in addressing the problem of medication errors among their resident population, who are usually older and have numerous chronic conditions. The aim of this study was two-fold: to examine the extent of use of Electronic Medication Management (EMM) in RCFs and to analyze the organizational factors associated with the use of EMM functionalities in RCFs. Data on RCFs were obtained from the 2010 National Survey of Residential Care Facilities. The association between facility, director and staff, and resident characteristics of RCFs and adoption of four EMM functionalities was assessed through multivariate logistic regression. The four EMM functionalities included were maintaining lists of medications, ordering for prescriptions, maintaining active medication allergy lists, and warning of drug interactions or contraindications. About 12% of the RCFs adopted all four EMM functionalities. Additionally, maintaining lists of medications had the highest adoption rate (34.5%), followed by maintaining active medication allergy lists (31.6%), ordering for prescriptions (19.7%), and warning of drug interactions or contraindications (17.9%). Facility size and ownership status were significantly associated with adoption of all four EMM functionalities. Medicaid certification status, facility director's age, education and license status, and the use of personal care aides in the RCF were significantly associated with the adoption of some of the EMM functionalities. EMM is expected to improve the quality of care and patient safety in long-term care facilities including RCFs. The extent of adoption of the four EMM functionalities is relatively low in RCFs. Some RCFs may strategize to use these functionalities to cater to the increasing demands from the market and also to

  16. Current Status and Issues of Nuclear Engineering Research and Educational Facilities in Universities

    International Nuclear Information System (INIS)

    2004-01-01

    It is important to discuss about nuclear engineering research and educational facilities in universities after new educational foundation. 12 universities investigated issues and a countermeasure of them. The results of a questionnaire survey, issues and countermeasure are shown in this paper. The questionnaire on the future nuclear researches, development of education, project, maintenance of nuclear and radioactive facilities and accelerator, control of uranium in subcritical test facilities, use of new corporation facilities, the fixed number of student, number of graduate, student experiments, themes of experiments and researches, the state of educational facilities are carried out. The results of questionnaire were summarized as followings: the fixed number of student (B/M/D) on nuclear engineering, exercise of reactor, education, themes, educational and research facilities, significance of nuclear engineering education in university and proposal. (S.Y.)

  17. Analysis of Student Satisfaction Toward Quality of Service Facility

    Science.gov (United States)

    Napitupulu, D.; Rahim, R.; Abdullah, D.; Setiawan, MI; Abdillah, LA; Ahmar, AS; Simarmata, J.; Hidayat, R.; Nurdiyanto, H.; Pranolo, A.

    2018-01-01

    The development of higher education is very rapid rise to the tight competition both public universities and private colleges. XYZ University realized to win the competition, required continuous quality improvement, including the quality of existing service facilities. Amenities quality services is believed to support the success of the learning activities and improve user satisfaction. This study aims to determine the extent to which the quality of the services effect on user satisfaction. The research method used is survey-based questionnaire that measure perception and expectation. The results showed a gap between perception and expectations of the respondents have a negative value for each item. This means XYZ service facility at the university is not currently meet the expectations of society members. Three service facility that has the lowest index is based on the perception of respondents is a laboratory (2.56), computer and multimedia (2.63) as well as wifi network (2.99). The magnitude of the correlation between satisfaction with the quality of service facilities is 0.725 which means a strong and positive relationship. The influence of the quality of service facilities to the satisfaction of the students is 0.525 meaning that the variable quality of the services facility can explain 52.5% of the variable satisfaction. The study provided recommendations for improvements to enhance the quality of services facility at the XYZ university facilities.

  18. [Autonomy for financial management in public and private healthcare facilities in Brazil].

    Science.gov (United States)

    Santos, Maria Angelica Borges dos; Madeira, Fátima Carvalho; Passos, Sonia Regina Lambert; Bakr, Felipe; Oliveira, Klivia Brayner de; Andreazzi, Marco Antonio Ratzsch de

    2014-01-01

    Autonomy in financial management is an advantage in public administration. A 2009 National Healthcare Facility Survey showed that 3.9% of Brazil's 52,055 public healthcare facilities had some degree of financial autonomy. Such autonomy was more common in inpatient facilities (17.8%), those managed by State governments (26.3%), and in Southern Brazil (6.6%). Autonomy was mainly partial (for resources in specific areas, relating to small outlays, consumables and capital goods, and outsourced services or personnel). 74.3% of 2,264 public facilities with any financial autonomy were under direct government administration. Financial autonomy in public healthcare facilities appears to be linked to local political decisions and not necessarily to the facility's specific legal and administrative status. However, legal status displays distinct scopes of autonomy - those under direct government administration tend to be less autonomous, and those under private businesses more autonomous; 85.8% of the 45,394 private healthcare facilities reported that they were financially autonomous.

  19. Organisational culture in residential aged care facilities: a cross-sectional observational study.

    Science.gov (United States)

    Etherton-Beer, Christopher; Venturato, Lorraine; Horner, Barbara

    2013-01-01

    Organisational culture is increasingly recognised as important for provision of high-quality long-term care. We undertook this study to measure organisational culture in residential aged care facilities in two Australian states. Cross-sectional observational study in 21 residential aged care facilities in Western Australia (n = 14) and Queensland (n = 7), Australia. Staff and next-of-kin of residents participated. Measurement comprised surveys of facility staff and residents' next-of-kin, and structured observation of indicators of care quality. Staff tended to rate organisational culture positively. Some qualitative feedback from staff emphasised negative perceptions of communication, leadership and teamwork. Staffing levels were perceived as a dominant challenge, threatening care quality. Direct observation revealed variability within and between facilities but suggested that most facilities (n = 12) were in the typical range, or were quality facilities (n = 8). There was scope to strengthen organisational culture in participating aged care facilities.

  20. Survey of Aquaponics in Europe

    Directory of Open Access Journals (Sweden)

    Morris Villarroel

    2016-10-01

    Full Text Available International aquaponic production has increased over the past decade, but less is known about research activities and production facilities operating in Europe. We conducted an online survey to get a better idea about research and production in Europe, focusing on five areas of aquaponics (i.e., demographics, facilities used, fish and crops produced, funding sources, and personal or company priorities for further development. The 68 respondents were distributed among 21 European countries, 43% were working at a university, and 19% were commercial producers. Only 11.8% of those surveyed had sold fish or plants in the past 12 months. Most respondents were male (66.2% and had a post-graduate degree (91.7%. Facilities were generally new (74.5% constructed after 2010 and self-designed. Production figures were modest, with less than 10 respondents producing more than 1000 kg of fish or plants per year (mostly tilapia or catfish and herbs or lettuce. Systems were often funded by government grants (35.3%. The great majority of respondents (80.4% stated that aquaponics was not their main source of income. Most respondents prioritized using aquaponics for educational purposes, while few (25% used it to produce their own food or improve their health. Questions related to personal knowledge about aquaponics underlined the need for more training about fish diseases and plant pests.

  1. The proposed irradiation facility and applications

    International Nuclear Information System (INIS)

    Singson, C.C.; Navarro, Q.O.

    As early as 1972, the Philippine Atomic Energy Commission proposed the setting up of a radiation facility for the sterilization of medical products. A result of a market survey with the assistance of an IAEA expert was conducted to determine the market potential for such venture. With the Food Terminal, Inc. (FTI) a government agro-industrial fair which explored the economic benefits of project, encouraging results have been obtained with finances from FAO and IAEA. The proposed pilot plant will serve as a multi purpose facility for the sterilization of medical and laboratory products, irradiation of food and agricultural produce and manufacture of wood plastic compositions for the textile and furniture industries. With the benefits derived from the said project, it is hoped that its early installation be pushed through. (author)

  2. Development of a hand-held fast neutron survey meter

    International Nuclear Information System (INIS)

    Yoshida, T.; Tsujimura, N.; Yamano, T.

    2011-01-01

    A neutron survey meter with a ZnS(Ag) scintillator to measure recoil protons was built. The detection probe weighs ∼2 kg, therefore providing us with true portability. Performance tests exhibited satisfactory neutron dosimetry characteristics in unmoderated or lightly moderated fission neutron fields and in particular work environments at a mixed oxide fuel facility. This new survey meter will augment a routine of neutron monitoring that is inconveniently being carried out by moderator-based neutron survey meters. (authors)

  3. Present status of ESNIT (energy selective neutron irradiation test facility) program

    International Nuclear Information System (INIS)

    Noda, K.; Ohno, H.; Sugimoto, M.; Kato, Y.; Matsuo, H.; Watanabe, K.; Kikuchi, T.; Sawai, T.; Usui, T.; Oyama, Y.; Kondo, T.

    1994-01-01

    The present status of technical studies of a high energy neutron irradiation facility, ESNIT (energy selective neutron irradiation test facility), is summarized. Technological survey and feasibility studies of ESNIT have continued since 1988. The results of technical studies of the accelerator, the target and the experimental systems in ESNIT program were reviewed by an International Advisory Committee in February 1993. Recommendations for future R and D on ESNIT program are also summarized in this paper. ((orig.))

  4. Underground gas storage in the World - Cedigaz survey

    International Nuclear Information System (INIS)

    Benquey, R.

    2010-01-01

    The 2010 edition of 'Underground Gas Storage in the World' provides an update to the previous survey released by CEDIGAZ in 2006. At that time, 610 underground gas storage (UGS) facilities were in operation worldwide, with a working capacity of 319 billion cubic metres (bcm). As of 1 January 2010, this number had reached 642 facilities with a working gas capacity of 333 bcm, or 10.8% of world gas consumption. By 2020, the global UGS demand is expected to grow at a pace of 3.3% per year, and according to the projects identified, more than 760 UGS sites could be active in the world with a total working capacity of approximately 465 bcm. In this survey, CEDIGAZ analyses the following trends which characterise the rapid development of underground gas storage in the world: - the strong dynamics of the European storage market, where 127 projects could add 75 bcm of working capacity by 2020, - the continued development of the UGS market in the United States (49 projects), encouraged by market-based rates allowed by the FERC, and rapid permitting processes, - the development of facilities in countries with little or no storage capacities at present, in Asia/Oceania, the C.I.S., and Eastern Europe in particular. This survey provides an analysis of the recent evolutions in the technic-economic aspects of the underground gas storage business, as well as an overview of the UGS markets and their developments in the world, country by country. A specific section is dedicated to the analysis of future UGS needs in Europe by 2020: - Technic-economic aspects of UGS: This part of the survey analyses the latest technical improvements and research axes in the field of underground gas storage. As it is more difficult to build greenfield storage facilities, a lot of work has been done to improve the performance and flexibility of existing storage sites. This section also deals with the evolution of investment and operational costs in storage over the last few years. Furthermore, the

  5. Joint CDRH (Center for Devices and Radiological Health) and state quality-assurance surveys in nuclear medicine: Phase 2 - radiopharmaceuticals

    International Nuclear Information System (INIS)

    Hamilton, D.R.; Evans, C.D.

    1986-08-01

    The report discusses survey results on aspects of the quality assurance of radio-pharmaceuticals from 180 nuclear-medicine facilities in the United States. Data were collected from facilities in 8 states. Demographic information about nuclear-medicine operations and quality-assurance programs was gathered by state radiation-control-program personnel. The data collected from the survey show an incomplete acceptance of quality-assurance practices for radiopharmaceuticals. Most of the facilities in the survey indicated that, because an inferior radiopharmaceutical was prepared so infrequently, they did not believe it was cost-effective to perform extensive quality-assurance testing. The Center for Devices and Radiological Health hopes that the information from the survey will stimulate nuclear-medicine professionals and their organizations to encourage appropriate testing of all radiopharmaceuticals

  6. Access to comprehensive emergency obstetric and newborn care facilities in three rural districts of Sindh province, Pakistan.

    Science.gov (United States)

    Ansari, Muhammad Shahid; Manzoor, Rabia; Siddiqui, Nasim; Ahmed, Ahsan Maqbool

    2015-11-25

    Pakistan's maternal and child health indicators remain unacceptably high, with a maternal mortality ratio of 276 per 100,000 live births and a neonatal mortality rate of 55 per 1,000 live births. Provision of basic and comprehensive emergency obstetric and newborn care is mandated by the government; however, coverage, access, and utilisation levels remain unsatisfactory, with the situation in Sindh province being amongst the worst in the country. This study attempted to assess access to comprehensive emergency obstetric and newborn care (C-EmONC) facilities and barriers hampering access in Sindh. One public sector hospital in each of three districts in Sindh province providing C-EmONC services were selected for a facility exit survey. A cross-sectional household survey and focus group discussions were conducted in the catchment population of these hospitals. Overall, 82% and 96% of those who utilised a public or private C-EmONC facility, respectively, incurred out-of-pocket expenditure. As expected, those living more than 5 km from the facility reported higher mean expenditure than those living within 5 km of the facility. More than half of the respondents (55%) among public sector users and the majority (71%) of private sector users could not afford travel costs. More than one third (35%) of public sector users and about two thirds (64%) of private sector users who could not afford travel costs took loans. The proportion of respondents who took loans was higher among those living more than 5 km of the health facility compared to those living within a 5 km distance. The majority of respondents (70%) in the community survey chose to go to a private sector C-EmONC facility. In addition to poverty, in terms of sociocultural access, religious and ethnic discrimination and the poor attitude of facility staff were amongst the most important barriers to accessing a C-EmONC facility. C-EmONC facilities in both the public and private sectors may simply not be accessible and

  7. Audiology Assistants: Results of a Multicenter Survey.

    Science.gov (United States)

    Karzon, Roanne; Hunter, Lisa; Steuerwald, Wendy

    2018-05-01

    Although audiologists have been using support personnel for over 45 yr, controversy and variability continue with respect to the entry-level education, training methods, and scope of practice. As part of a larger clinical practices survey, this report focuses on use of audiology assistants (AAs) for pediatric settings and "life-span" facilities that had a significant population of pediatric patients. A questionnaire was sent to 116 facilities in geographically diverse locations. Of the 25 surveys returned, 22 had sufficient data to be included for analysis purposes. The majority of respondents assigned duties to AAs as follows: assisting with conditioned play audiometry and visual reinforcement audiometry, infection control, mail management, disposing of protected health information, ordering supplies, calling families, fielding family phone calls, and stocking supplies. In addition, of the nine pediatric facilities that used AAs and reported job duties, the majority assigned troubleshooting equipment and auditory brainstem response (ABR) screening. Two of the five life-span facilities that reported job duties assigned several duties not assigned by any of the pediatric facilities: pure-tone screening, earmold impressions, assisting with videonystagmography and ABR, and in-house hearing aid repairs. Of facilities that use AAs and reported staffing, the ratio of AAs to audiologists ranged from 0.03:1 to 1:0.37, with an average of 0.15 for life-span facilities and 0.17 for the pediatric facilities. Minimum educational levels required were reported as follows: high school (n = 8), college (n = 3), certificate (n = 1), and no requirement (n = 1). Within a small sample size of pediatric and life-span facilities, 14 of 22 centers used AAs to perform a variety of direct patient care, indirect patient care, and clerical duties. Based on the duties recommended within the American Speech-Language-Hearing Association guidelines and by many states, expanded employment of AAs

  8. Smokefree signage at New Zealand racecourses and sports facilities with outdoor stands.

    Science.gov (United States)

    Thomson, George; Wilson, Nick

    2017-10-27

    Smokefree signage is crucial to the implementation of smokefree policies for outdoor venues and for facilitating smoking denormalisation. Such signage helps to communicate the expected norms for not smoking at venues. Therefore, we aimed to identify such signage at racecourses and sports facilities that had outdoor stands. We surveyed the entrances of 25 racecourse and 25 sport facilities with outdoor stands, across New Zealand. There were smokefree signs at the main entrances of 40% of the sports facilities with outdoor stands, and at 16% of the 25 other entrances. None of the horse/greyhound racecourses had smokefree signage at any of their entrances.

  9. Development of inherent technologies for advanced PWR core - A study on the current status and the construction feasibility of critical facilities

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Won Sik; Yang, Hyun Seok [Chosun University, Kwangju (Korea); Kim, Chang Hyo; Shim, Hyung Jin [Seoul National University, Seoul (Korea)

    1999-03-01

    The objective of this study is to examine the appropriateness of constructing critical facilities in our country and to decide a course of constructing them if necessary by surveying the status and utilization of foreign facilities and by investigating the demand for domestic facilities. We investigated the status and the utilization of foreign critical facilities through literature survey and personal visitation. In our judgement, critical facilities are necessary for developing the advanced reactors and fuels which are being studied as parts of the Nuclear R and D Program by MOST. Considering the construction cost and the current state of domestic economy, however, it is unjustifiable to build three different types of critical facilities (the light water, the heavy water, and the fast critical facility). It appears to be reasonable to build a light water critical, considering the construction cost, degree of utilization, and other constraints. (author). 89 refs., 134 figs., 64 tabs.

  10. Social assessment of siting a low-level radioactive waste storage facility in Michigan

    International Nuclear Information System (INIS)

    Stoffle, R.W.; Traugott, M.J.; Stone, J.V.; McIntyre, P.D.; Davidson, C.C.; Jensen, F.V.; Coover, G.E.

    1990-01-01

    This report presents findings from a social assessment of siting a low-level radioactive waste storage facility in Michigan. Social assessments derive from direct interaction between researchers and study participants. The report is organized into five chapters. Chapter One, Summary of Findings, focuses on key findings from the statewide telephone surveys and the in-depth ethnographic study conducted by the SNR/ISR study team. These and additional findings are discussed in greater detail in the three subsequent chapters. Chapter Two, Statewide Telephone Survey Findings, presents the knowledge, attitudes and beliefs statewide residents have regarding the LLRW project. Chapter Three, Statewide Demographic Findings, presents a detailed examination of differences among various demographic groups and includes regional analysis. Chapter Four, Hillsdale-area Ethnographic Study Findings, discusses perceived impacts of the proposed LLRW storage facility on local residents who mistakenly came to believe that their area had been specially selected as the location for the facility. Specifically, the chapter presents the development, spread, shape and persistence of what is termed a risk perception shadow in the greater Hillsdale area. Possible causes of the shadow also are discussed, and comparisons are made between statewide and Hillsdale-area survey populations. Chapter Five, Research Methods, presents a discussion of the social assessment research methods used to derive these findings

  11. Facilities of Early Rehabilitation after Stroke in Poland 2010

    Science.gov (United States)

    Opara, Jozef A.; Langhorne, Peter; Larsen, Torben; Mehlich, Krzysztof; Szczygiel, Jaroslaw

    2012-01-01

    The aim of this work was to survey the contemporary facilities for early post-stroke rehabilitation in Poland. The main research questions were as follows: what is the availability of inpatient rehabilitation for post-stroke patients in neurological departments and in rehabilitation departments? The growing costs of healthcare are encouraging…

  12. Survey of radioactive contamination of foodstuffs

    International Nuclear Information System (INIS)

    Lee, W. R.; Lee, C. W.; Choi, G. S.; Cho, Y. H.; Kang, M. J.; Cheong, K. H.; Kim, H. R.; Kwak, J. Y.

    2005-11-01

    The purpose of this study is to survey and assess radioactive contamination of foodstuffs in order to reduce the probability of intake of contaminated foodstuffs. Based on survey and assessment, final goal is to improve the public health by radiation protection. Sampled foodstuffs items are collected from the markets : one group are imported foodstuffs and the other group are domestic foodstuffs producted around nuclear facilities. After pretreatments such as drying, ashing, and homogenization, all samples were analyzed by gamma spectrometer system. The 137 Cs radionuclide was only measured among the regulation radionuclides ( 137 Cs, 134 Cs, 131 I) of food code. All radionuclides of the domestic foodstuffs collected around nuclear facilities were below Minimum Detectable Activity (MDA). But the activity concentrations of Inonotus obliquus (Chaga mushooms) from Russia ranged up to 171.27 (average value : 36.65) Bq/kg-fresh. In the case of blueberry jam, the radioactivity of 137 Cs is higher than expected value. Other samples are below MDA except some spices. Based on the previous and present results, it should be strengthen to survey for Inontus obliquus (Chaga mushooms), of which the radioactivity shows the range from MDA up to 800.01 Bq/kg-fresh. It should assess the public radiation exposure via food chain because it has the excess provability of the maximum permitted level of food code, which is regulation of KFDA. The development method based on international standard would be used at radioactive analysis as well as education of practical workers and it could be applied as the basis data for amending the analysis method of food code. Our country only surveys gamma emitting radionuclides till now but international organization or foreign countries for example EU survey alpha and beta emitting radionuclides as well as gamma emitting radionuclides. So our country should also research necessity of survey for alpha and beta emitting radionuclides

  13. Technology assessment of multileaf collimation: a North American users survey

    International Nuclear Information System (INIS)

    Klein, Eric E.; Tepper, Joel; Sontag, Mark; Franklin, Michael; Ling, Clifton; Kubo, Dale

    1999-01-01

    Purpose: The American Association of Physicists in Medicine (AAPM) initiated an Assessment of Technology Subcommittee (ATS) to help the radiotherapy community evaluate emerging technologies. The ATS decided to first address multileaf collimation (MLC) by means of a North American users survey. The survey attempted to address issues such as MLC utility, efficacy, cost-effectiveness, and customer satisfaction. Methods and Materials: The survey was designed with 38 questions, with cross-tabulation set up to decipher a particular clinic's perception of MLC. The surveys were coded according to MLC types, which were narrowed to four: Elekta, Siemens, Varian 52-leaf, and Varian 80-leaf. A 40% return rate was desired. Results: A 44% (108 of 250) return was achieved. On an MLC machine, 76.5% of photon patients are being treated with MLC. The main reasons for not using MLC were stair stepping, field size limitation, and physician objection. The most common sites in which MLC is being used are lung, pelvis, and prostate. The least used sites are head and neck and mantle fields. Of the facilities, 31% claimed an increase in number of patients being treated since MLC was installed, and 44% claimed an increase in the number of fields. Though the staffing for block cutting has decreased, therapist staffing has not. However, 91% of the facilities claimed a decreased workload for the therapists, despite the increase in daily treated patients and fields. Of the facilities that justified MLC purchase for more daily patients, 63% are actually treating more patients. Only 26% of the facilities that justified an MLC purchase for intensity-modulated radiotherapy (IMRT) are currently using it for that purpose. The satisfaction rating (1 = low to 5 = high) for department groups averaged 4.0. Therapists ranked MLC as 4.6. Conclusions: Our survey shows that most users have successfully introduced MLC into the clinic as a block replacement. Most have found MLC to be cost-effective and

  14. Post-remedial-action radiological survey report for the Plutonium Facility of the Battelle Memorial Institute, Columbus Division, West Jefferson Complex, West Jefferson, Ohio, April 1980-June 1982

    International Nuclear Information System (INIS)

    Flynn, K.F.; Justus, A.L.; Sholeen, C.M.; Smith, W.H.; Wynveen, R.A.

    1987-01-01

    The post-remedial-action surveys involved only the remaining, newer segment of the original Plutonium Facility and those outdoor environs at the former location of the buried autoclave and old holding tanks. The assessment activities conducted during the three surveys included determination of surface contamination levels, both fixed and removable, through direct instrument and smear surveys; measurement of ambient external penetrating radiation levels at 1-meter heights throughout the involved areas; measurement of the concentrations of radon, thoron, and actinon daughters and longer-lived radionuclides within air samples; and determination of concentrations of uranium, plutonium, americium, neptunium, the thorium-232 decay chain, and the radium-226 decay chain in soil and other material samples from the involved areas. The direct instrument and smear surveys were performed on all accessible floor, wall, and overhead surfaces and ductwork in the laboratory and corridor areas, mechanical room, and men's locker room, where the false ceiling, formerly at the 12-ft level, had been removed. In the office areas, the accessible floors, walls, and overheads were surveyed to the height of the existing 8-ft false ceiling. Although the office areas were adjacent to, not part of, the affected areas, it was possible that radioactive materials could have been carried by the ventilation system, spilled, or otherwise tracked into these adjacent areas. In some building areas, surfaces might hae been retiled, painted, or otherwise covered since the beginning of use of radioactive materials; however, the instruments used for the direct survey had some capability to detect beta-gamma activity on the underlying surfaces. 5 refs., 8 figs., 8 tabs

  15. CERN Radiation Protection (RP) calibration facilities

    CERN Document Server

    AUTHOR|(CDS)2082069; Macián-Juan, Rafael

    Radiation protection calibration facilities are essential to ensure the correct operation of radiation protection instrumentation. Calibrations are performed in specific radiation fields according to the type of instrument to be calibrated: neutrons, photons, X-rays, beta and alpha particles. Some of the instruments are also tested in mixed radiation fields as often encountered close to high-energy particle accelerators. Moreover, calibration facilities are of great importance to evaluate the performance of prototype detectors; testing and measuring the response of a prototype detector to well-known and -characterized radiation fields contributes to improving and optimizing its design and capabilities. The CERN Radiation Protection group is in charge of performing the regular calibrations of all CERN radiation protection devices; these include operational and passive dosimeters, neutron and photon survey-meters, and fixed radiation detectors to monitor the ambient dose equivalent, H*(10), inside CERN accelera...

  16. Field Research Facility Data Integration Framework Data Management Plan: Survey Lines Dataset

    Science.gov (United States)

    2016-08-01

    Geographic Information System ERDC/CHL SR-16-4 viii GPS global positioning system ID identification ISO International Organization for...Time Kinematic Global Positioning System SDSFIE Spatial Data Standards for Facilities, Infrastructure, and Environment TOPO topographic TSS...Resupply Cargo V (LARC-V) vessel which is capable of continuous data collection from the beach, through the surf zone, and offshore. Conductivity

  17. Site characterization of ORNL D ampersand D facilities

    International Nuclear Information System (INIS)

    Kelsey, A.P.; Mandry, G.J.; Haghighi, M.H.

    1994-01-01

    Site characterization for decontamination and decommissioning (D ampersand D) planning purposes was done for two surplus facilities at Oak Ridge National Laboratory (ORNL) in late 1993 and early 1994. This site characterization includes measurements of radiological and chemical contaminants, assessment of general structural conditions, and investigation of unknown conditions within the buildings. It will serve as input to decisions on D ampersand D engineering, D ampersand D task sequences, radiological and contamination control, and waste management. This paper presents the methods used to investigate these facilities and discusses the preliminary results as they apply to D ampersand D planning. Investigation methods include gross alpha, beta, and gamma surveys; directional gamma surveys; gamma spectroscopy; concrete coring; photography; and collection of soil and miscellaneous samples that are analyzed for radiological and chemical contaminants. Data will be analyzed using radiological models to sort sources and estimate exposure rates and waste volumes due to D ampersand D. The former Waste Evaporator Facility (WEF), consisting of two concrete cells and an operating gallery, once contained a liquid radwaste evaporator. Subsequently it was used for an incinerator experiment and as a dressing area for remediation work on an adjacent tank farm. The building has been partially decontaminated. Figure 1 is a photograph of the WEF. The Fission Product Pilot Plant (FPPP) is a small concrete building containing two cells. It was used to extract isotopes of ruthenium, strontium, cesium, cerium, and other elements from liquid waste. This facility is highly contaminated. In 1960 all doors into FPPP were sealed with concrete block and mortar, and concrete block shielding was added to the external walls making them up to five feet thick. Prior to this study, almost nothing was known about the interior of this building

  18. Using Tools of Strategic Management in Medical Facilities of Lublin Region

    Directory of Open Access Journals (Sweden)

    Jaworzynska Magdalena

    2017-06-01

    Full Text Available The purpose of this article is to evaluate the use of tools of strategic management in hospitals in Lublin region. The study was conducted among 14 medical entities from the area of Lublin Voivodeship. The survey was addressed to economic directors or chief accountants of health care facilities and sent by post. The questionnaire was also helpful in conducting an in-depth interview as it provided a required structure. As part of the interviews with managers of health care facilities, information beyond the questionnaire was acquired, e.g. about the mission. According to studies, most health care facilities develop strategic plans (71.4%. For 21.4% of the studied facilities, the strategic plan is known mainly to management. In contrast, 28.6% of entities do not have a strategic plan. The presented results of the research can increase the effectiveness of activities in each area of the health care facility, continuous process improvement and rapid response to changes in the environment.

  19. Current internal-dosimetry practices at US Department of Energy facilities

    International Nuclear Information System (INIS)

    Traub, R.J.; Murphy, B.L.; Selby, J.M.; Vallario, E.J.

    1985-04-01

    The internal dosimetry practice at DOE facilities were characterized. The purpose was to determine the size of the facilities' internal dosimetry programs, the uniformity of the programs among the facilities, and the areas of greatest concern to health physicists in providing and reporting accurate estimates of internal radiation dose and in meeting proposed changes in internal dosimetry. The differences among the internal-dosimetry programs are related to the radioelements in use at each facility and, to some extent, the number of workers at each facility. The differences include different frequencies in the use of quality control samples, different minimum detection levels, different methods of recording radionuclides, different amounts of data recorded in the permanent record, and apparent differences in modeling the metabolism of radionuclides within the body. Recommendations for improving internal-dosimetry practices include studying the relationship between air-monitoring/survey readings and bioassay data, establishing uniform methods for recording bioassay results, developing more sensitive direct-bioassay procedures, establishing a mechanism for sharing information on internal-dosimetry procedures among DOE facilities, and developing mathematical models and interactive computer codes that can help quantify the uptake of radioactive materials and predict their distribution in the body. 19 refs., 8 tabs

  20. Calibration and evaluation of neutron survey meters used at linac facility

    Energy Technology Data Exchange (ETDEWEB)

    Salgado, A.P. [Instituto de Radioprotecao e Dosimetria - IRD, Av. Salvador Allende s/n, Recreio dos Bandeirantes, CEP 22780-160 Rio de Janeiro (Brazil); Pereira, W.W., E-mail: walsan@ird.gov.b [Instituto de Radioprotecao e Dosimetria - IRD, Av. Salvador Allende s/n, Recreio dos Bandeirantes, CEP 22780-160 Rio de Janeiro (Brazil); Fonseca, E.S. da; Patrao, K.C.S. [Instituto de Radioprotecao e Dosimetria - IRD, Av. Salvador Allende s/n, Recreio dos Bandeirantes, CEP 22780-160 Rio de Janeiro (Brazil); Batista, D.V.S. [Instituto Nacional do Cancer - INCa, Praca Cruz Vermelha, 23 - centro, CEP 20230-130 Rio de Janeiro (Brazil)

    2010-12-15

    Calibrated survey meters from the Neutron Laboratory of the Instituto de Radioprotecao e Dosimetria (IRD) were used to determine the ambient dose-equivalent rate in a 15 MV linear accelerator treatment room at the Instituto Nacional do Cancer (INCa). Three different models of neutron survey meters were calibrated using four neutron radionuclide neutron sources: {sup 241}AmBe({alpha},n), {sup 252}Cf(f,n), heavy-water moderated {sup 252}Cf(f,n), and {sup 238}PuBe({alpha},n). All neutron sources were standardized in a Manganese Sulphate Bath (MSB) absolute primary system. The response of each of these instruments was compared with reference values of ambient dose-equivalent rate. The results demonstrate the complexity of making measurements in the mixed neutron/photon field produced in electron linear accelerator radiotherapy treatment rooms.

  1. A new standard method for the surveying and alignment of beamline facilities at GSI

    Energy Technology Data Exchange (ETDEWEB)

    Wirth, H. [Metronom, Gesellschaft fuer Industrievermessung mbH, Mainz (Germany); Moritz, G.

    1996-01-01

    The GSI institute of heavy ion research is financed by the country of Germany. Founded in 1969, the main emphasis of the institute`s work is the research of the characteristics of atomic nuclei. The Universal Linear Accelerator UNILAC was built first and in 1987 new facilities were added to the setup. The GSI accelarators allow acceleration of all atomic nuclei up to Uranium to an energy of 20 MeV/u. In 1993 Metronome started working on a new alignment concept for the GSI`s accelerators. Metronome has developed the TASA concept. TSAS stands for Techeometric Accelerator Surveying and Alignment and is based on the new generation of high-precision total stations. One feature included in the TASA Concept, has been the replacement of all mobile plates by fixed consoles. An immense advantage of new fixed consoles, welded onto every component, is that they can be positioned to locations where they can be easily measured, simply by taking measuring conditions (lines of sight, heights of stands, error-figures, configuration, etc.) into consideration. The TASA Concept can be used for all alignments of the different GSI accelerators. For all accelerators a special investigation was carried out to check if it is possible to position a new pillar system and to install new consoles on the components. The free positioning of fiducial points makes it possible to use polar measurements for all components. This is an enormous advantage and a step forward for alignment procedures at GSI. Furthermore, use of a total station as opposed to the ECDS System means that one operator less is needed. (S.Y.)

  2. The Hannibal Community Survey; A Case Study in a Community Development Technique.

    Science.gov (United States)

    Croll, John A.

    Disturbed by the community's negative attitude toward its prospects for progress, the Hannibal (Missouri) Chamber of Commerce initiated a community self-survey to improve the situation. The questionnaire survey concentrated on felt needs relationg to city government, retail facilities and services, recreation, religion, education, industrial…

  3. Service readiness, health facility management practices, and delivery care utilization in five states of Nigeria: a cross-sectional analysis.

    Science.gov (United States)

    Gage, Anastasia J; Ilombu, Onyebuchi; Akinyemi, Akanni Ibukun

    2016-10-06

    Existing studies of delivery care in Nigeria have identified socioeconomic and cultural factors as the primary determinants of health facility delivery. However, no study has investigated the association between supply-side factors and health facility delivery. Our study analyzed the role of supply-side factors, particularly health facility readiness and management practices for provision of quality maternal health services. Using linked data from the 2005 and 2009 health facility and household surveys in the five states in which the Community Participation for Action in the Social Sector (COMPASS) project was implemented, indices of health service readiness and management were developed based on World Health Organization guidelines. Multilevel logistic regression models were run to determine the association between these indices and health facility delivery among 2710 women aged 15-49 years whose last child was born within the five years preceding the surveys and who lived in 51 COMPASS LGAs. The health facility delivery rate increased from 25.4 % in 2005 to 44.1 % in 2009. Basic amenities for antenatal care provision, readiness to deliver basic emergency obstetric and newborn care, and management practices supportive of quality maternal health services were suboptimal in health facilities surveyed and did not change significantly between 2005 and 2009. The LGA mean index of basic amenities for antenatal care provision was more positively associated with the odds of health facility delivery in 2009 than in 2005, and in rural than in urban areas. The LGA mean index of management practices was associated with significantly lower odds of health facility delivery in rural than in urban areas. The LGA mean index of facility readiness to deliver basic emergency obstetric and neonatal care declined slightly from 5.16 in 2005 to 3.98 in 2009 and was unrelated to the odds of health facility delivery. Supply-side factors appeared to play a role in health facility delivery

  4. Measuring Athletic Facility Managers’ Knowledge Of Access And The Americans With Disabilities Act: A Pilot Study

    OpenAIRE

    Joshua R. Pate; Steven N. Waller

    2012-01-01

    The purpose of this exploratory research was measuring facility managers’ knowledge of the Americans with Disabilities Act (ADA), and it may assist in decreasing the gap in knowledge between facility managers and the needs of people with physical disabilities. An existing survey examining ADA knowledge was slightly modified and used for this study. Four athletic facility managers from universities in a large Bowl Championship Series conference participated in the study. Results provided a pre...

  5. Redshift Survey Strategies

    Science.gov (United States)

    Jones, A. W.; Bland-Hawthorn, J.; Kaiser, N.

    1994-12-01

    In the first half of 1995, the Anglo-Australian Observatory is due to commission a wide field (2.1(deg) ), 400-fiber, double spectrograph system (2dF) at the f/3.3 prime focus of the AAT 3.9m bi-national facility. The instrument should be able to measure ~ 4000 galaxy redshifts (assuming a magnitude limit of b_J ~\\ 20) in a single dark night and is therefore ideally suited to studies of large-scale structure. We have carried out simple 3D numerical simulations to judge the relative merits of sparse surveys and contiguous surveys. We generate a survey volume and fill it randomly with particles according to a selection function which mimics a magnitude-limited survey at b_J = 19.7. Each of the particles is perturbed by a gaussian random field according to the dimensionless power spectrum k(3) P(k) / 2pi (2) determined by Feldman, Kaiser & Peacock (1994) from the IRAS QDOT survey. We introduce some redshift-space distortion as described by Kaiser (1987), a `thermal' component measured from pairwise velocities (Davis & Peebles 1983), and `fingers of god' due to rich clusters at random density enhancements. Our particular concern is to understand how the window function W(2(k)) of the survey geometry compromises the accuracy of statistical measures [e.g., P(k), xi (r), xi (r_sigma ,r_pi )] commonly used in the study of large-scale structure. We also examine the reliability of various tools (e.g. genus) for describing the topological structure within a contiguous region of the survey.

  6. Test facility of proton beam utilization of the PEFP at the SNU-AMS tandem accelerator

    International Nuclear Information System (INIS)

    Kim, K. R.; Park, B. S.; Lee, H. R.

    2004-01-01

    The PEFP (Proton Engineering Frontier Project) will supply users with a 20-MeV proton beam by the middle of 2007. A survey on users' demand was performed to draw the concept for the 20-MeV user facilities and to investigate users' requirements. In the mean time, a 6-MeV test facility has been developed to give users opportunities to experiment with proton beams. That facility will be attached to the 3-MV tandem accelerator at Seoul National University.

  7. Health physics experience with nondestructive X-radiation facilities in the US Air Force

    International Nuclear Information System (INIS)

    Stencel, J.R.; Piltingsrud, H.V.

    1976-01-01

    Radiation safety experience in the construction and use of enclosed nondestructive inspection (NDI) facilities in the US Air Force, has reaffirmed the constant need for the health physicist to continually monitor and assit in upgrading these facilities. Health physics contributions include evaluation of initial shielding requirements, proper selection of construction material, insuring that adequate safety devices are installed and adequate personnel dosimetry devices are available, surveying the facility, and assisting in the safety education program. There is a need to better define NDI warning/safety devices, using the National Bureau of Standards, (NBS) Handbook 107 as the most applicable guide

  8. Do service innovations influence the adoption of electronic health records in long-term care organizations? Results from the U.S. National Survey of Residential Care Facilities.

    Science.gov (United States)

    Bhuyan, Soumitra S; Zhu, He; Chandak, Aastha; Kim, Jungyoon; Stimpson, Jim P

    2014-12-01

    Healthcare organizations including residential care facilities (RCFs) are diversifying their services to meet market demands. Service innovations have been linked to the changes in the way that healthcare organizations organize their work. The objective of this study is to explore the relationship between organizational service innovations and Electronic Health Record (EHR) adoption in the RCFs. We used the data from the 2010 National Survey of Residential Care Facilities conducted by the Centers for Disease Control and Prevention. The outcome was whether an RCF adopted EHR or not, and the predictors were the organizational service innovations including provision of skilled nursing care and medication review. We also added facility characteristics as control variables. Weighted multivariate logistic regressions were used to estimate the relationship between service innovation factors and EHR adoption in the RCFs. In 2010, about 17.4% of the RCFs were estimated to use EHR. Multivariate analysis showed that RCFs employing service innovations were more likely to adopt EHR. The residential care facilities that provide skilled nursing services to their residents are more likely (OR: 1.42; 95% CI: 1.09-1.87) to adopt EHR. Similarly, RCFs with a provision of medication review were also more likely to adopt EHR (OR: 1.40; 95% CI: 1.00-1.95). Among the control variables, facility size, chain affiliation, ownership type, and Medicaid certification were significantly associated with EHR adoption. Our findings suggest that service innovations may drive EHR adoption in the RCFs in the United States. This can be viewed as a strategic attempt by RCFs to engage in a new business arrangement with hospitals and other health care organizations, where quality of care and interoperability of patients' records might play a vital role under the current healthcare reform. Future research could examine the relationship between service innovations and use of different EHR functionality in

  9. Bat Surveys of Retired Facilitiies Scheduled for Demolition by Washington Closure Hanford

    Energy Technology Data Exchange (ETDEWEB)

    Gano, K. A.; Lucas, J. G.; Lindsey, C. T.

    2011-06-30

    This project was conducted to evaluate buildings and facilities remaining in the Washington Closure Hanford (WCH) deactivation, decontamination, decommissioning, and demolition schedule for bat roost sites. The project began in spring of 2009 and was concluded in spring of 2011. A total of 196 buildings and facilities were evaluated for the presence of bat roosting sites. The schedule for the project was prioritized to accommodate the demolition schedule. As the surveys were completed, the results were provided to the project managers to facilitate planning and project completion. The surveys took place in the 300 Area, 400 Area, 100-H, 100-D, 100-N, and 100-B/C Area. This report is the culmination of all the bat surveys and summarizes the findings by area and includes recommended mitigation actions where bat roosts were found.

  10. Training practices of cell processing laboratory staff: analysis of a survey by the Alliance for Harmonization of Cellular Therapy Accreditation.

    Science.gov (United States)

    Keever-Taylor, Carolyn A; Slaper-Cortenbach, Ineke; Celluzzi, Christina; Loper, Kathy; Aljurf, Mahmoud; Schwartz, Joseph; Mcgrath, Eoin; Eldridge, Paul

    2015-12-01

    Methods for processing products used for hematopoietic progenitor cell (HPC) transplantation must ensure their safety and efficacy. Personnel training and ongoing competency assessment is critical to this goal. Here we present results from a global survey of methods used by a diverse array of cell processing facilities for the initial training and ongoing competency assessment of key personnel. The Alliance for Harmonisation of Cellular Therapy Accreditation (AHCTA) created a survey to identify facility type, location, activity, personnel, and methods used for training and competency. A survey link was disseminated through organizations represented in AHCTA to processing facilities worldwide. Responses were tabulated and analyzed as a percentage of total responses and as a percentage of response by region group. Most facilities were based at academic medical centers or hospitals. Facilities with a broad range of activity, product sources and processing procedures were represented. Facilities reported using a combination of training and competency methods. However, some methods predominated. Cellular sources for training differed for training versus competency and also differed based on frequency of procedures performed. Most facilities had responsibilities for procedures in addition to processing for which training and competency methods differed. Although regional variation was observed, training and competency requirements were generally consistent. Survey data showed the use of a variety of training and competency methods but some methods predominated, suggesting their utility. These results could help new and established facilities in making decisions for their own training and competency programs. Copyright © 2015 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  11. U.S. Department of Energy Office of Legacy Management Calibration Facilities - 12103

    Energy Technology Data Exchange (ETDEWEB)

    Barr, Deborah [U.S. Department of Energy Office of Legacy Management, Grand Junction, Colorado (United States); Traub, David; Widdop, Michael [S.M. Stoller Corporation, Grand Junction, Colorado (United States)

    2012-07-01

    This paper describes radiometric calibration facilities located in Grand Junction, Colorado, and at three secondary calibration sites. These facilities are available to the public for the calibration of radiometric field instrumentation for in-situ measurements of radium (uranium), thorium, and potassium. Both borehole and hand-held instruments may be calibrated at the facilities. Aircraft or vehicle mounted systems for large area surveys may be calibrated at the Grand Junction Regional Airport facility. These calibration models are recognized internationally as stable, well-characterized radiation sources for calibration. Calibration models built in other countries are referenced to the DOE models, which are also widely used as a standard for calibration within the U.S. Calibration models are used to calibrate radiation detectors used in uranium exploration, remediation, and homeland security. (authors)

  12. FINESSE: study of the issues, experiments and facilities for fusion nuclear technology research and development. Interim report. Volume I

    International Nuclear Information System (INIS)

    Abdou, M.

    1984-10-01

    The following chapters are included in this study: (1) fusion nuclear issues, (2) survey of experimental needs, (3) requirements of the experiments, (4) non-fusion facilities, (5) fusion facilities for nuclear experiments, and (6) fusion research and development scenarios

  13. Norm survey in Argentina

    International Nuclear Information System (INIS)

    Canoba, Analia Cecilia; Gnoni, Gabriela Alejandra; Truppa, W.

    2008-01-01

    The oil and gas industry, which is especially significant in Argentina, is one industry that concentrates natural radionuclides during its processes. In addition, there are a few underground mines under development, where radon levels may be high. The Nuclear Regulatory Authority of Argentina (ARN) carried out a project with the objective of evaluating NORM, mainly in these types of industries. Eight facilities were characterized, three related to the gas industry, four related to the oil industry and a survey of radon gas in a gold underground mine. First, background measurements were made and then a screening survey was carried out to detect values above background. Of the values obtained, 57% were in the background range, 19% were below 2 μSv/h, 15% were in the range 2-10 μSv/h and 9% were above 10 μSv/h. Some values were as high as 400 μSv/h. The annual effective doses were estimated to be in the range 0.02-1.6 mSv/a. Samples were taken and later analysed by gamma spectrometry, liquid scintillation and fluorimetry. It was confirmed that the main radionuclides involved in the oil and gas extraction process are 226 Ra and 228 Ra. The radium isotope concentrations measured in some samples were above the exemption values established by the International Basic Safety Standards. Elevated radon levels were detected in gas facilities and in the gold mine under development. The values obtained in gas facilities showed that radon concentrates in the ethane and propane flows. As the flows in the gas industry are confined, it does not mean an exposure during normal operation. In the case of the gold mine, the values detected were informed to the pertinent authorities as well as the facility in order to take actions to reduce concentrations below the action levels. Finally, protective measures to reduce occupational doses in the cleaning and maintenance processes were suggested, as well as for storage of NORM-contaminated items. (author)

  14. Emission Facilities - Erosion & Sediment Control Facilities

    Data.gov (United States)

    NSGIC Education | GIS Inventory — An Erosion and Sediment Control Facility is a DEP primary facility type related to the Water Pollution Control program. The following sub-facility types related to...

  15. Mapping the Characteristics of Critical Care Facilities: Assessment, Distribution, and Level of Critical Care Facilities from Central India.

    Science.gov (United States)

    Saigal, Saurabh; Sharma, Jai Prakash; Pakhare, Abhijit; Bhaskar, Santosh; Dhanuka, Sanjay; Kumar, Sanjay; Sabde, Yogesh; Bhattacharya, Pradip; Joshi, Rajnish

    2017-10-01

    In low- and middle-income countries such as India, where health systems are weak, the number of available Critical Care Unit (Intensive Care Unit [ICU]) beds is expected to be low. There is no study from the Indian subcontinent that has reported the characteristics and distribution of existing ICUs. We performed this study to understand the characteristics and distribution of ICUs in Madhya Pradesh (MP) state of Central India. We also aimed to develop a consensus scoring system and internally validate it to define levels of care and to improve health system planning and to strengthen referral networks in the state. We obtained a list of potential ICU facilities from various sources and then performed a cross-sectional survey by visiting each facility and determining characteristics for each facility. We collected variables with respect to infrastructure, human resources, equipment, support services, procedures performed, training courses conducted, and in-place policies or standard operating procedure documents. We identified a total of 123 ICUs in MP. Of 123 ICUs, 35 were level 1 facilities, 74 were level 2 facilities, and only 14 were level 3 facilities. Overall, there were 0.17 facilities per 100,000 population (95* confidence interval [CI] 0.14-0.20 per 100,000 populations). There were a total of 1816 ICU beds in the state, with an average of 2.5 beds per 100,000 population (95* CI 2.4-2.6 per 100,000 population). Of the total number of ICU beds, 250 are in level 1, 1141 are in level 2, and 425 are in level 3 facilities. This amounts to 0.34, 1.57, and 0.59 ICU beds per 100,000 population for levels 1, 2, and 3, respectively. This study could just be an eye opener for our healthcare authorities at both state and national levels to estimate the proportion of ICU beds per lac population. Similar mapping of intensive care services from other States will generate national data that is hitherto unknown.

  16. Scientific substantiation of approaches to organization and conducting radiation surveys at the rehabilitated radiation sites

    Directory of Open Access Journals (Sweden)

    I. K. Romanovich

    2017-01-01

    Full Text Available The article is concerned with the scientific justification of approaches to the organization of the final radiation survey of facilities having radioactive contamination, after their rehabilitation. Scientific publications on the previous experience in rehabilitation of facilities contaminated with radionuclides, the organization and conducting a radiation survey before the start of the decontamination, during its implementation and after its completion were analyzed. The experience in the rehabilitation of the site for the temporary storage of spent fuel and radioactive waste in Andreeva Bay in the North-West region of Russia, the locations of peaceful nuclear explosions, experimental nuclear power plants, a radiochemical laboratory, and metallurgical plants, that do not belong to radiation facilities, has been studied. It has been established that, besides the surface contamination of the soil, areas of radioactive contamination on sites of decommissioned radiation facilities with significant depth up to 15 m along the profile are available. These local zones with depth soil contamination are persistent contaminants of the groundwater. The experience in the radiation survey of the peaceful nuclear explosions sites shows the removal of radionuclides from cavities, formed with the use of nuclear explosive technologies for peaceful purposes, on the earth’s surface. An optimized list of radionuclides to be monitored during the radiological survey of rehabilitated facilities was proposed based on the analysis of the composition of radionuclides detected at radiation sites subjected to decontamination. The optimized list includes 14 radionuclides with the half-lives of more than three years. 

  17. Identifying the gaps in infection prevention and control resources for long-term care facilities in British Columbia.

    Science.gov (United States)

    Gamage, Bruce; Schall, Valerie; Grant, Jennifer

    2012-03-01

    Infection prevention and control (IPC) is a critical, although often neglected, part of long-term care (LTC) management. Little is known about what IPC resources are available for LTC and how that impacts patient care and safety. One hundred eighty-eight LTC facilities were randomly selected out of all British Columbia facilities and surveyed using a validated survey tool. The tool was used to collect data regarding IPC resources grouped within 6 indices: (1) leadership, (2) infection control professionals (ICP) coverage, (3) policies and procedures, (4) support through partnerships, (5) surveillance, and (6) control activities. All components measured have been identified as key for an effective IPC program. Survey responses were used to calculate scores for IPC programs as a whole and for each of the 6 indices. Of 188 randomly selected facilities, 86 institutions participated. Facilities were compared by region, funding source, and ICP coverage. Overall, LTC facilities lacked IPC leadership, especially physician support. Having no dedicated ICP was associated with poorer scores on all indices. Only 41% of practicing ICPs had more than 2 years experience, and only 14% were professionally certified. Twenty-two percent of ICPs had additional roles within the institution, and 44% had additional roles outside of the institution. Thirty-five percent of institutions had no IPC dedicated budget. LTC institutions-with bed numbers exceeding those in acute care-represent an important aspect of health services. These data show that many LTC facilities lack the necessary resources to provide quality infection control programs. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  18. Survey of international personnel radiation dosimetry programs

    International Nuclear Information System (INIS)

    Swaja, R.E.

    1985-04-01

    In September of 1983, a mail survey was conducted to determine the status of external personnel gamma and neutron radiation dosimetry programs at international agencies. A total of 130 agencies participated in this study including military, regulatory, university, hospital, laboratory, and utility facilities. Information concerning basic dosimeter types, calibration sources, calibration phantoms, corrections to dosimeter responses, evaluating agencies, dose equivalent reporting conventions, ranges of typical or expected dose equivalents, and degree of satisfaction with existing systems was obtained for the gamma and neutron personnel monitoring programs at responding agencies. Results of this survey indicate that to provide the best possible occupational radiation monitoring programs and to improve dosimetry accuracy in performance studies, facility dosimetrists, regulatory and standards agencies, and research laboratories must act within their areas of responsibility to become familiar with their radiation monitoring systems, establish common reporting guidelines and performance standards, and provide opportunities for dosimetry testing and evaluation. 14 references, 10 tables

  19. Optimization of detector size and scan rate for beta/gamma material release surveys

    International Nuclear Information System (INIS)

    Bishop, R.V.

    1993-01-01

    DOE facilities are required to offer for sale to the public items of salvageable value when they are no longer required by the facilities. These items have to be surveyed to ensure radioactive contamination levels do not exceed the values listed in DOE Order 5400.5. Most facilities use portable contamination monitoring.equipment with probe areas between 20 and 100 cm 2 to check for fixed contamination. This procedure is very labor intensive and results in survey costs that often exceed the costs recovered from selling the items. A solution would be to use large area (> 100 cm 2 ) detectors to find and quantify contamination. Large area scintillation detectors that can be used for beta and alpha detection simultaneously are becoming available commercially. Combining these with a rate meter that can differentiate between alpha and beta events can result in a survey that takes considerably less time to do and will save a proportional amount of money in doing so. The use and limitations of this combination of detectors and rate meters will be discussed

  20. The California Baseline Methane Survey

    Science.gov (United States)

    Duren, R. M.; Thorpe, A. K.; Hopkins, F. M.; Rafiq, T.; Bue, B. D.; Prasad, K.; Mccubbin, I.; Miller, C. E.

    2017-12-01

    The California Baseline Methane Survey is the first systematic, statewide assessment of methane point source emissions. The objectives are to reduce uncertainty in the state's methane budget and to identify emission mitigation priorities for state and local agencies, utilities and facility owners. The project combines remote sensing of large areas with airborne imaging spectroscopy and spatially resolved bottom-up data sets to detect, quantify and attribute emissions from diverse sectors including agriculture, waste management, oil and gas production and the natural gas supply chain. Phase 1 of the project surveyed nearly 180,000 individual facilities and infrastructure components across California in 2016 - achieving completeness rates ranging from 20% to 100% per emission sector at < 5 meters spatial resolution. Additionally, intensive studies of key areas and sectors were performed to assess source persistence and variability at times scales ranging from minutes to months. Phase 2 of the project continues with additional data collection in Spring and Fall 2017. We describe the survey design and measurement, modeling and analysis methods. We present initial findings regarding the spatial, temporal and sectoral distribution of methane point source emissions in California and their estimated contribution to the state's total methane budget. We provide case-studies and lessons learned about key sectors including examples where super-emitters were identified and mitigated. We summarize challenges and recommendations for future methane research, inventories and mitigation guidance within and beyond California.

  1. Use of ICT facilities for teaching library and information science ...

    African Journals Online (AJOL)

    This article investigated availability and functionality of ICT facilities and its utilization in the teaching of Library and Information Science (LIS) students in the University of Uyo. The study adopted a survey design and was guided by four objectives, four research questions, and two hypotheses. The population of the study ...

  2. 76 FR 34720 - Chemical Facility Anti-Terrorism Standards Personnel Surety Program

    Science.gov (United States)

    2011-06-14

    ... are currently required for employment or access to secure areas of those facilities. Background On... individuals in order to clarify suspected data errors or resolve potential matches (e.g., in situations where...., affirmations or certifications of compliance, extension requests, brief surveys for process improvement, etc...

  3. Radiological survey results at 5 Porter Street, Beverly, Massachusetts (VB019)

    International Nuclear Information System (INIS)

    Foley, R.D.; Johnson, C.A.

    1992-07-01

    At the request of the US Department of Energy (DOE), a team from Oak Ridge National Laboratory conducted a radiological survey at 5 Porter Street, Beverly, Massachusetts. The survey was performed in May 1991. The purpose of the survey was to determine if uranium from work performed under government contract at the former Ventron facility had migrated off-site to neighboring areas. The survey included a surface gamma scan and the collection of soil samples for radionuclide analyses. Results of the survey demonstrated no radionuclide concentrations or radiation measurements in excess of the DOE Formerly Utilized Site Remedial Action Program guidelines

  4. Radiological survey results at 2 Porter Street, Beverly, Massachusetts (VB005)

    International Nuclear Information System (INIS)

    Foley, R.D.; Carrier, R.F.

    1992-08-01

    At the request of the US Department of Energy (DOE), a team from Oak Ridge National Laboratory conducted a radiological survey at 2 Porter Street, Beverly, Massachusetts. The survey was performed in May 1991. The purpose of the survey was to determine if uranium dust from work performed under government contract at the former Ventron facility had migrated off-site to neighboring areas. The survey included a surface gamma scan and the collection of soil samples fore radionuclide analyses. Results of the survey demonstrated no radionuclide concentrations or radiation measurements in excess of the DOE Formerly Utilized Sites Remedial Action Program guidelines

  5. Radiological survey results at 9 Porter Street, Beverly, Massachusetts (VB020)

    International Nuclear Information System (INIS)

    Foley, R.D.; Johnson, C.A.

    1992-07-01

    At the request of the US Department of Energy (DOE), a team from Oak Ridge National Laboratory conducted a radiological survey at 9 Porter Street, Beverly, Massachusetts. The survey was performed in May 1991. The purpose of the survey was to determine if uranium from work performed under government contract at the former Ventron facility had migrated off-site to neighboring areas. The survey included a surface gamma scan and the collection of soil samples for radionuclide analyses. Results of the survey demonstrated no radionuclide concentrations or radiation measurements in excess of the DOE Formerly Utilized Sites Remedial Action Program guidelines

  6. Maintenance, repair and operation (MRO) of shutdown facilities

    International Nuclear Information System (INIS)

    Kenny, S.

    2006-01-01

    What level of maintenance does one apply to a shutdown facility? Well it depends on who you ask. Operations staff sees facilities that have completed their useful life cycle as a cost drain while Decommissioning staff sees this as the start of a new life cycle. Based on the decommissioning plan for the particular facility the building could complete another full life cycle while under decommissioning whether it is in storage with surveillance mode or under active decommissioning. This paper will explore how you maintain a facility and systems for many years after its useful life until final decommissioning is completed. When a building is declared redundant, who looks after it until the final decommissioning end state is achieved? At the AECL, Chalk River Labs site the safe shutdown and turnover process is one key element that initiates the decommissioning process. The real trick is orchestrating maintenance, repair and operation plans for a facility that has been poorly invested in during its last years of useful life cycle. To add to that usually shutdowns are prolonged for many years beyond the expected turnover period. During this presentation I will cover what AECL is doing to ensure that the facilities are maintained in a proper state until final decommissioning can be completed. All facilities or systems travel through the same life cycle, design, construction, commissioning, operation, shutdown and demolition. As we all know, nuclear facilities add one more interesting twist to this life cycle called Decommissioning that lands between shutdown and demolition. As a facility nears the shutdown phase, operations staff loose interest in the facility and stop investing in upgrades, repairs and maintenance but continue to invest and focus on maximizing operations. Facility maintenance standards produced by the International Facility Maintenance Association (IFMA) based on a survey done every year state that 2.2% of the total operating costs for the site should be

  7. The utility of point count surveys to predict wildlife interactions with wind energy facilities: An example focused on golden eagles

    Science.gov (United States)

    Sur, Maitreyi; Belthoff, James R.; Bjerre, Emily R.; Millsap, Brian A.; Katzner, Todd

    2018-01-01

    Wind energy development is rapidly expanding in North America, often accompanied by requirements to survey potential facility locations for existing wildlife. Within the USA, golden eagles (Aquila chrysaetos) are among the most high-profile species of birds that are at risk from wind turbines. To minimize golden eagle fatalities in areas proposed for wind development, modified point count surveys are usually conducted to estimate use by these birds. However, it is not always clear what drives variation in the relationship between on-site point count data and actual use by eagles of a wind energy project footprint. We used existing GPS-GSM telemetry data, collected at 15 min intervals from 13 golden eagles in 2012 and 2013, to explore the relationship between point count data and eagle use of an entire project footprint. To do this, we overlaid the telemetry data on hypothetical project footprints and simulated a variety of point count sampling strategies for those footprints. We compared the time an eagle was found in the sample plots with the time it was found in the project footprint using a metric we called “error due to sampling”. Error due to sampling for individual eagles appeared to be influenced by interactions between the size of the project footprint (20, 40, 90 or 180 km2) and the sampling type (random, systematic or stratified) and was greatest on 90 km2 plots. However, use of random sampling resulted in lowest error due to sampling within intermediate sized plots. In addition sampling intensity and sampling frequency both influenced the effectiveness of point count sampling. Although our work focuses on individual eagles (not the eagle populations typically surveyed in the field), our analysis shows both the utility of simulations to identify specific influences on error and also potential improvements to sampling that consider the context-specific manner that point counts are laid out on the landscape.

  8. Implementing a province-wide mandatory vaccinate-or-mask policy at healthcare facilities in British Columbia, Canada.

    Science.gov (United States)

    Nunn, Alexandra; Campbell, Audrey C; Naus, Monika; Kwong, Jeffrey C; Puddicombe, David; Quach, Susan; Henry, Bonnie

    2018-01-08

    In 2012, British Columbia (BC) became the first Canadian province to implement an influenza prevention policy requiring healthcare workers (HCW) to either be vaccinated annually against influenza or wear a mask in patient care areas during the influenza season. This study describes an evaluation of influenza policy implementation processes and identifies supports and challenges related to successful policy implementation at the level of healthcare facilities, during the second policy year (2013/14). Implementation leaders from 262 long-term care (LTC) and acute care facilities, mostly in three of BC's five regional Health Authorities, were invited to participate in an online survey following the 2013/14 influenza season. Descriptive quantitative and qualitative analyses identified common and effective strategies for improving vaccination coverage and policy compliance. A total of 127 respondents completed the survey on behalf of 33 acute care and 99 LTC facilities, representing 36% of acute care and 27% of LTC facilities in BC. Respondents agreed that the policy was successfully implemented at 89% of facilities, and implementation was reported to be easy at 52% of facilities. The findings elaborate on communication and leadership strategies, campaign logistics and enforcement approaches involved in policy implementation. Implementation of a vaccinate-or-mask influenza policy is complex. This study provides insight for other jurisdictions considering implementing such a policy and offers practical recommendations for facilities and health authorities. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Preparedness of elderly long-term care facilities in HSE East for influenza outbreaks.

    LENUS (Irish Health Repository)

    O'Connor, L

    2015-01-01

    Abstract We assessed preparedness of HSE East elderly long-term care facilities for an influenza outbreak, and identified Public Health Department support needs. We surveyed 166 facilities based on the HSE checklist document for influenza outbreaks, with 58% response rate. Client flu vaccination rates were > 75%; leading barriers were client anxiety and consent issues. Target flu vaccine uptake of 40% in staff occurred in 43% of facilities and was associated with staff vaccine administration by afacility-attached GP (p = 0.035), having a facility outbreak plan (p = 0.013) and being anon-HSE run facility (p = 0.013). Leading barriers were staff personal anxiety (94%) and lack of awareness of the protective effect on clients (21%). Eighty-nine percent found Public Health helpful, and requested further educational support and advocacy. Staff vaccine uptake focus, organisational leadership, optimal vaccine provision models, outbreak plans and Public Health support are central to the influenza campaign in elderly long-term care facilities.

  10. The European Synchrotron Radiation Facility - an overview of planned diffraction capability

    International Nuclear Information System (INIS)

    Kvick, A.

    1991-01-01

    The European Synchrotron Radiation Facility (ESRF) is a third generation synchrotron radiation facility presently being built as a joint venture between 12 European countries in Grenoble, France. The ESRF will be a low emittance 6 GeV storage ring aimed at producing high-brilliance synchrotron radiation from 29 insertion devices and from 27 bending magnet ports. The general user program will start in the middle of 1994 with seven ESRF beam-lines. By 1999, 30 facility beam-lines as well as beam-lines built and financed by Collaborating Research Groups are scheduled to be in operation. The guidelines for the first beam-lines to be constructed as well as a survey of the diffraction oriented beam-lines built by the ESRF are given in the article. (author)

  11. Administrators' perspectives on end-of-life care for cancer patients in Japanese long-term care facilities.

    Science.gov (United States)

    Fukahori, Hiroki; Miyashita, Mitsunori; Morita, Tatsuya; Ichikawa, Takayuki; Akizuki, Nobuya; Akiyama, Miki; Shirahige, Yutaka; Eguchi, Kenji

    2009-10-01

    The purpose of this study was to clarify administrators' perspectives on availability of recommended strategies for end-of-life (EOL) care for cancer patients at long-term care (LTC) facilities in Japan. A cross-sectional survey was conducted with administrators at Japanese LTC facilities. Participants were surveyed about their facilities, reasons for hospitalization of cancer patients, and their perspectives on availability of and strategies for EOL care. The 97 responses were divided into medical facility (n = 24) and non-medical facility (n = 73) groups according to physician availability. The most frequent reasons for hospitalization were a sudden change in patient's condition (49.4%), lack of around-the-clock care (43.0%), and inability to palliate symptoms (41.0%). About 50% of administrators believed their facilities could provide EOL care if supported by palliative care experts. There was no significant difference between facility types (P = 0.635). Most administrators (81.2%) regarded unstable cancer patients as difficult to care for. However, many (68.4%) regarded opioids given orally as easy to administer, but regarded continuous subcutaneous infusion/central venous nutrition as difficult. Almost all administrators believed the most useful strategy was transferring patients to hospitals at the request of patients or family members (96.9%), followed by consultation with palliative care experts (88.5%). Although LTC facilities in Japan currently do not provide adequate EOL care for cancer patients, improvement might be possible with support by palliative care teams. Appropriate models are necessary for achieving a good death for cancer patients. Interventions based on these models are necessary for EOL care for cancer patients in LTC facilities.

  12. The facilities management market in Denmark

    DEFF Research Database (Denmark)

    Jensen, Per Anker

    2010-01-01

    for researching the market but particular the definition of space including acquisition as well as development, administration, operation, maintenance and utilities in the same main product is problematic. Research limitations/implications: The market research is limited to the Danish market, but the results......Purpose: To present the results of market surveys in Denmark, which have been based on and used to test a proposal for a new European standard for a taxonomy of Facilities Management (FM). Design/methodology: The market research included surveys of both the client side and the provider side...... and was carried out by a management consultant company by telephone interviews based on definitions developed from drafts for the European FM taxonomy standard by a university researcher, who is a member of the standardisation work group. Findings: The proposed taxonomy for FM is in general a good basis...

  13. Facilities management: Structuring a body of knowledge for continuing and tertiary education in South Africa

    Directory of Open Access Journals (Sweden)

    A. C. Hauptfleisch

    2010-01-01

    is exacerbated by the fact that very little is being done at the level of continuing education and formal tertiary education in South Africa. The limited attempts in this regard are furthermore taking place in isolation, with practically no dialogue between the limited facilities management industry and the providers of the limited education that is available.Although the study that was undertaken did not have the objective to create comprehensive interaction between the existing role-players, the stated problems were addressed by involving the industry, participants in continuing education programmes and other role-players in the condensed research problem as stated below. The problem at hand is firstly to extract, from the present practice of facilities management, a knowledge framework and secondly to formulate the results in terms of suitable continuing and tertiary education programmes to address the shortcomings in South Africa. Research was therefore undertaken to address the structuring of educational programmes. The methodology applied comprised a comprehensive literature survey and three quantified and qualified data surveys, the latter conducted amongst facilities management practitioners, primarily the perceived beneficiaries of such programmes. These surveys provided information that led to the resultant educational activities stated below. The most important aspects that were determined were the following: It was possible to create and test amongst facilities management practitioners a diagrammatic presentation that contextualised facilities management. The literature survey, including international and South African sources, contributed towards compiling a primary knowledge framework for facilities management. The perceived value of the contents of a continuing education programme that had been attended by numerous groups of delegates over a number of years was established. A proposed tertiary education programme was presented to practitioners

  14. Aerial radiological survey of the Fermi National accelerator Laboratory and surrounding area, Batavia, Illinois. Data of survey: 12-14 May 1977

    International Nuclear Information System (INIS)

    Jobst, J.E.

    1981-01-01

    An aerial radiological survey was conducted over the facilities of the Fermi National Accelerator Laboratory (Fermilab) near Batavia, Illinois on 12-14 May 1977. The survey was flown at an altitude of 91 m by a helicopter containing 20 sodium iodide detectors. The line spacing was also 91 m. Enhanced gamma exposure rate levels, which could be attributed to Fermilab operations, were observed at seven locations. One additional anomaly, not related to the Laboratory, was also discovered

  15. A rock characterisation facility consultative document

    International Nuclear Information System (INIS)

    1992-10-01

    This U.K. Nirex Ltd., consultative document describes a proposed underground rock characterisation facility, east of Sellafield, for conducting geophysical surveys as a basis for refining long-term safety analysis of an underground repository for intermediate-level and low-level radioactive wastes. Planning application will be submitted in 1993. The construction of shafts and galleries is described and the site's geologic, topographical, climatic and archaeological features discussed. The effects to the local environment and on local populations and other socio-economic factors are discussed. (UK)

  16. Spatially resolved emission spectroscopic investigation of microwave-induced reactive low-power plasma jets

    International Nuclear Information System (INIS)

    Arnold, Thomas; Grabovski, Sergey; Schindler, Axel; Wagner, Hans-Erich

    2004-01-01

    A microwave-induced Ar/SF 6 plasma jet is characterized by means of optical emission spectroscopy. Rotational temperatures from unresolved N 2 bands and excitation temperatures from Fe lines as well as electron densities (H β Stark broadening) have been estimated along the plasma jet axis using a side-on configuration. The SF 6 gas flow rate and chamber pressure were varied from 10 to 250 sccm and 20 to 500 mbar, respectively. Three characteristic jet regions have been observed: the plasma ignition zone, followed by the gas mixing zone and a relaxing zone

  17. Wide-Field Astronomical Surveys in the Next Decade

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, Michael A.; /Princeton U.; Tyson, J.Anthony; /UC, Davis; Anderson, Scott F.; /Washington U., Seattle, Astron. Dept.; Axelrod, T.S.; /LSST Corp.; Becker, Andrew C.; /Washington U., Seattle, Astron. Dept.; Bickerton, Steven J.; /Princeton U.; Blanton, Michael R.; /New York U.; Burke, David L.; /SLAC; Condon, J.J.; /NRAO, Socorro; Connolly, A.J.; /Washington U., Seattle, Astron. Dept.; Cooray, Asantha R.; /UC, Irvine; Covey, Kevin R.; /Harvard U.; Csabai, Istvan; /Eotvos U.; Ferguson, Henry C.; /Baltimore, Space Telescope Sci.; Ivezic, Zeljko; /Washington U., Seattle, Astron. Dept.; Kantor, Jeffrey; /LSST Corp.; Kent, Stephen M.; /Fermilab; Knapp, G.R.; /Princeton U.; Myers, Steven T.; /NRAO, Socorro; Neilsen, Eric H., Jr.; /Fermilab; Nichol, Robert C.; /Portsmouth U., ICG /Harish-Chandra Res. Inst. /Caltech, IPAC /Potsdam, Max Planck Inst. /Harvard U. /Hawaii U. /UC, Berkeley, Astron. Dept. /Baltimore, Space Telescope Sci. /NOAO, Tucson /Carnegie Mellon U. /Chicago U., Astron. Astrophys. Ctr.

    2011-11-14

    Wide-angle surveys have been an engine for new discoveries throughout the modern history of astronomy, and have been among the most highly cited and scientifically productive observing facilities in recent years. This trend is likely to continue over the next decade, as many of the most important questions in astrophysics are best tackled with massive surveys, often in synergy with each other and in tandem with the more traditional observatories. We argue that these surveys are most productive and have the greatest impact when the data from the surveys are made public in a timely manner. The rise of the 'survey astronomer' is a substantial change in the demographics of our field; one of the most important challenges of the next decade is to find ways to recognize the intellectual contributions of those who work on the infrastructure of surveys (hardware, software, survey planning and operations, and databases/data distribution), and to make career paths to allow them to thrive.

  18. 76 FR 28121 - Notice of Passenger Facility Charge (PFC) Approvals and Disapprovals

    Science.gov (United States)

    2011-05-13

    ... fencing. Acquire radio equipment for emergency operations center. Interactive employee training system... survey and wildlife assessment. Decision Date: March 17, 2011. FOR FURTHER INFORMATION CONTACT: Lori...: Aircraft rescue and firefighting facility. Determination: The approval of this project is limited to the...

  19. Decommissioning of a Radioactive Facility Used for Biomolecule Labeling and Biological Effects; Desclasificación de una Instalación Radiactiva Dedicada al Marcado de Biomoléculas y Efectos Biológicos

    Energy Technology Data Exchange (ETDEWEB)

    Yagüe, L.; Navarro, N.; Álvarez, A.; Quiñones, J.

    2015-07-01

    This paper presents the measurement methodology designed for the final status survey of an old radioactive facility, used as radiolabeling lab. Its declassification as radioactive facility required the radiological characterization of all walls, structures and materials at the facility in order to reuse its outbuilding for conventional use. To demonstrate compliance with the declassification criteria, the design of the final status survey was performed applying MARSSIM(1) (Multi-Agency Radiation Survey and Site Investigation Manual) methodology and using different measurement techniques depending on the radioactive isotopes in the inventory of the facility, their half-lives and emission characteristics.

  20. Delivering information: a descriptive study of Australian women's information needs for decision-making about birth facility.

    Science.gov (United States)

    Thompson, Rachel; Wojcieszek, Aleena M

    2012-06-18

    Little information is known about what information women want when choosing a birth facility. The objective of this study was to inform the development of a consumer decision support tool about birth facility by identifying the information needs of maternity care consumers in Queensland, Australia. Participants were 146 women residing in both urban and rural areas of Queensland, Australia who were pregnant and/or had recently given birth. A cross-sectional survey was administered in which participants were asked to rate the importance of 42 information items to their decision-making about birth facility. Participants could also provide up to ten additional information items of interest in an open-ended question. On average, participants rated 30 of the 42 information items as important to decision-making about birth facility. While the majority of information items were valued by most participants, those related to policies about support people, other women's recommendations about the facility, freedom to choose one's preferred position during labour and birth, the aesthetic quality of the facility, and access to on-site neonatal intensive care were particularly widely valued. Additional items of interest frequently focused on postnatal care and support, policies related to medical intervention, and access to water immersion. The women surveyed had significant and diverse information needs for decision-making about birth facility. These findings have immediate applications for the development of decision support tools about birth facility, and highlight the need for tools which provide a large volume of information in an accessible and user-friendly format. These findings may also be used to guide communication and information-sharing by care providers involved in counselling pregnant women and families about their options for birth facility or providing referrals to birth facilities.

  1. Insight from Public Surveys Related to Siting of Nuclear Waste Facilities: An Overview of Findings from a 2015 Nationwide Survey of US Residents

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins-Smith, Hank C. [Univ. of Oklahoma, Norman, OK (United States); Gupta, Kuhika [Univ. of Oklahoma, Norman, OK (United States); Silva, Carol L. [Univ. of Oklahoma, Norman, OK (United States); Bonano, Evaristo J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Rechard, Robert P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    The results described in this report are an analysis of nationwide surveys, administered between 2006 and 2015, which measure preferences of US residents concerning the environment and energy sources. The Energy & Environment (EE) survey series is conducted annually by the Center for Energy, Security & Society (CES&S), a joint research collaboration of the University of Oklahoma and Sandia National Laboratories. The annual EE survey series is designed to track evolving public views on nuclear materials management in the US. The 2015 wave of the Energy and Environment survey (EE15) was implemented using a web-based questionnaire, and was completed by 2,021 respondents using an Internet sample that matches the characteristics of the adult US population as estimated in the US Census. A special focus of the EE15 survey is how survey respondents understand and evaluate “consent” in the context of the storage and transportation of spent nuclear fuel (SNF). This report presents an overview of key results from analyses of questions related to consent-based siting and other elements of the nuclear energy fuel cycle.

  2. Mapping of health facilities in Jimeta Metropolis: a digital approach ...

    African Journals Online (AJOL)

    In planning for any suitable development in any field, the primary requirement is the relevant data and maps. This is one of the major problems hindering the proper planning and monitoring of the various health facilities located in Jimeta metropolis. Survey techniques -were employed for the acquisition of data, GPS was ...

  3. Assessment of the Optimization of E-Learning Facilities to Lecturers ...

    African Journals Online (AJOL)

    The study assessed the optimization of e-learning facilities to lecturers and students in Federal Colleges of Education in North West Zone of Nigeria. A descriptive survey was used. The population comprised all the lecturers and students in five (5) Federal Colleges of Education in the zone – numbering about 3,650 ...

  4. Problems Associated with the Use of Internet Facilities among Rural ...

    African Journals Online (AJOL)

    The survey was conducted in Benue State to analyze the major problems associated with the use of Internet facilities. The population of this study consisted of all rural farmers and extension workers in the study area. However, a sample size of 193 respondents was selected using purposive, snow ball and simple random ...

  5. ARM User Survey Report: Data Access, Quality, and Delivery

    Energy Technology Data Exchange (ETDEWEB)

    Mather, JH; Roeder, LR; Sivaraman, C

    2012-06-28

    The objective of this survey was to obtain user feedback to determine how users of the Atmospheric Radiation Measurement (ARM) Climate Research Facility Data Archive interact with the more than 2000 available types of datastreams. The survey also gathered information about data discovery and data quality. The Market and Competitive Analysis group at Pacific Northwest National Laboratory worked with web administrators to develop a landing page from which users could access the survey. A survey invitation was sent by ARM via email to about 6100 users on February 22, 2012. The invitation was also posted on the ARM website and Facebook page. Reminders were sent via e-mail and posted on Facebook while the survey was open, February 22-March 23, 2012.

  6. The Diesel Exhaust in Miners Study: IV. Estimating historical exposures to diesel exhaust in underground non-metal mining facilities.

    Science.gov (United States)

    Vermeulen, Roel; Coble, Joseph B; Lubin, Jay H; Portengen, Lützen; Blair, Aaron; Attfield, Michael D; Silverman, Debra T; Stewart, Patricia A

    2010-10-01

    We developed quantitative estimates of historical exposures to respirable elemental carbon (REC) for an epidemiologic study of mortality, including lung cancer, among diesel-exposed miners at eight non-metal mining facilities [the Diesel Exhaust in Miners Study (DEMS)]. Because there were no historical measurements of diesel exhaust (DE), historical REC (a component of DE) levels were estimated based on REC data from monitoring surveys conducted in 1998-2001 as part of the DEMS investigation. These values were adjusted for underground workers by carbon monoxide (CO) concentration trends in the mines derived from models of historical CO (another DE component) measurements and DE determinants such as engine horsepower (HP; 1 HP = 0.746 kW) and mine ventilation. CO was chosen to estimate historical changes because it was the most frequently measured DE component in our study facilities and it was found to correlate with REC exposure. Databases were constructed by facility and year with air sampling data and with information on the total rate of airflow exhausted from the underground operations in cubic feet per minute (CFM) (1 CFM = 0.0283 m³ min⁻¹), HP of the diesel equipment in use (ADJ HP), and other possible determinants. The ADJ HP purchased after 1990 (ADJ HP₁₉₉₀(+)) was also included to account for lower emissions from newer, cleaner engines. Facility-specific CO levels, relative to those in the DEMS survey year for each year back to the start of dieselization (1947-1967 depending on facility), were predicted based on models of observed CO concentrations and log-transformed (Ln) ADJ HP/CFM and Ln(ADJ HP₁₉₉₀(+)). The resulting temporal trends in relative CO levels were then multiplied by facility/department/job-specific REC estimates derived from the DEMS surveys personal measurements to obtain historical facility/department/job/year-specific REC exposure estimates. The facility-specific temporal trends of CO levels (and thus the REC

  7. Who delivers where? The effect of obstetric risk on facility delivery in East Africa.

    Science.gov (United States)

    Virgo, Sandra; Gon, Giorgia; Cavallaro, Francesca L; Graham, Wendy; Woodd, Susannah

    2017-09-01

    Skilled attendance at birth is key for the survival of pregnant women. This study investigates whether women at increased risk of maternal and newborn complications in four East African countries are more likely to deliver in a health facility than those at lower risk. Demographic and Health Survey data for Kenya 2014, Rwanda 2014-15, Tanzania 2015-16 and Uganda 2011 were used to study women with a live birth in the three years preceding the survey. A three-level obstetric risk index was created using known risk factors. Generalised linear Poisson regression was used to investigate the association between obstetric risk and facility delivery. We analysed data from 13 119 women across the four countries of whom 42-45% were considered at medium risk and 12-17% at high risk, and the remainder were at low risk. In Rwanda, 93% of all women delivered in facilities but this was lower (59-66%) in the other three countries. There was no association between a woman's obstetric risk level and her place of delivery in any country; greater wealth and more education were, however, independently strongly associated with facility delivery. In four East African countries, women at higher obstetric risk were not more likely to deliver in a facility than those with lower risk. This calls for a renewed focus on antenatal risk screening and improved communication on birth planning to ensure women with an increased chance of maternal and newborn complications are supported to deliver in facilities with skilled care. © 2017 John Wiley & Sons Ltd.

  8. Aerial radiological survey of the Idaho National Engineering Laboratory, Idaho Falls, Idaho. Date of survey: June 1982

    International Nuclear Information System (INIS)

    1984-02-01

    An aerial radiological survey of the Idaho National Engineering Laboratory (INEL) was conducted during June 1982 by EG and G Energy Measurements, Inc. for the United States Department of Energy (DOE). The survey consisted of airborne measurements of both natural and man-made gamma radiation from the terrain surface in and around the INEL site. These measurements allowed an estimate of the distribution of isotopic concentrations in the survey area. Results are reported as isopleths superimposed on maps and photographs of the area. Gamma ray energy spectra are also presented for the net man-made radionuclides. The survey was designed to cover all of the area within a 2 mile radius of any facility at the INEL. Several areas of man-made activity were detected. These areas are all known working or storage areas which are associated with normal operations at the INEL. 3 references, 48 figures, 5 tables

  9. Attitudes of Nursing Facilities' Staff Toward Pharmacy Students' Interaction with its Residents.

    Science.gov (United States)

    Adkins, Donna; Gavaza, Paul; Deel, Sharon

    2017-06-01

    All Appalachian College of Pharmacy second-year students undertake the longitudinal geriatric early pharmacy practice experiences (EPPE) 2 course, which involves interacting with geriatric residents in two nursing facilities over two semesters. The study investigated the nursing staff's perceptions about the rotation and the pharmacy students' interaction with nursing facility residents. Cross-sectional study. Academic setting. 63 nursing facility staff. A 10-item attitude survey administered to nursing staff. Nursing staff attitude toward pharmacy students' interaction with geriatric residents during the course. Sixty-three responses were received (84% response rate). Most respondents were female (95.2%), who occasionally interacted with pharmacy students (54.8%) and had worked at the facilities for an average of 6.8 years (standard deviation [SD] = 6.7) years. Staff reported that pharmacy students practiced interacting with geriatric residents and nursing facility staff, learned about different medications taken by residents as well as their life as a nursing facility resident. In addition, the student visits improved the mood of residents and staff's understanding of medicines, among others. Staff suggested that students spend more time with their residents in the facility as well as ask more questions of staff. The nursing facility staff generally had favorable attitudes about pharmacy students' visits in their nursing facility. Nursing facility staff noted that the geriatric rotation was a great learning experience for the pharmacy students.

  10. Treatment of plutonium-bearing solutions: A brief survey of the DOE complex

    International Nuclear Information System (INIS)

    Conner, C.; Chamberlain, D.B.; Chen, L.; Vandegrift, G.F.

    1995-03-01

    With the abrupt shutdown of some DOE facilities, a significant volume of in-process material was left in place and still requires treatment for interim storage. Because the systems containing these process streams have deteriorated since shutdown, a portable system for treating the solutions may be useful. A brief survey was made of the DOE complex on the need for a portable treatment system to treat plutonium-bearing solutions. A survey was completed to determine (1) the compositions and volumes of solutions and heels present, (2) the methods that have been used to treat these solutions and heels in the past, and (3) the potential problems that exist in removing and treating these solutions. Based on the surveys and on the Defense Nuclear Facilities Safety Board Recommendation 94-1, design criteria for a portable treatment system were generated

  11. FY 1999 report on the potential survey of the environmentally friendly type coal utilization system - Dispatch of engineers. A. Project for supporting the introduction of the environmentally friendly type coal utilization system (model project)/pre-survey for the potential survey; 1999 nendo kankyo chowa gata sekitan riyo system kanosei chosa. Senmomka haken A. kankyo chowa gata sekitan riyo system donyu shien jigyo (model jigyo) - Kanosei chosa no jizen chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    For the purpose of the improvement of coal utilization technology and environmental preservation, the paper conducted the pre-survey of the introduction of coke oven gas desulfurization facilities in China and pre-survey of potentiality of the environmentally friendly type coal utilization system in India. The pre-survey in China was made for Anyang Steel Group Co. Ltd. and Laiwu Steel Group Co. Ltd. to judge their adaptability as site for the demonstrative project on the introduction of coke oven gas desulfurization facilities. As a result, it was confirmed that the former satisfied the conditions on Japan side such as the space for installation and prospect for fund raising. However, the amount of COG treatment was larger than that planned at Japan side, and it was found that as to the recovered sulfur, the company wanted the solid sulfur different from the fused sulfur planned at Japan side. In the survey in India, explanations were made to India of CFBC and the fluidized bed cement sintering system, bio-briquette production facilities, facilities for environmental measures, coal reforming technology, etc. At the same time, the site survey was made to examine/analyze possibilities of spread/development of Japan's CCT. (NEDO)

  12. Radiation protection program at an accelerator facility complex

    International Nuclear Information System (INIS)

    Ramanuja, Jaya

    2007-01-01

    Broad aspects of Radiation Protection Program at the Tyco Healthcare/Mallinckrodt Inc. will be presented with emphasis on Occupational dose, Public dose and ALARA program. Regulatory requirements, compliance and radio nuclides of concern for external exposure and internal contamination will be discussed. The facility is subject to in depth annual inspections by the Nuclear Regulatory Commission (NRC) to ensure compliance with regulations and operating license requirements. The facility is required to have an emergency contingency plan in place. A simulated emergency drill scenario is witnessed and graded by the NRC and state inspectors, with full participation by the fire department and the local hospital. Radiation Safety Officer (RSO) is in charge of all radiological aspects of the facility, and reports to the plant manager directly. The RSO or any of his staff has the authority to stop a job if there is a radiological concern. The Radiation protection organization interfaces with Production, QA and Engineering and ensures there is no conflict with Industrial Safety, OSHA and FDA requirements. Any employee has the right to call the regulatory officials if he/she has a concern. Operational aspects of Radiation protection program such as radiological survey, contamination control and limits, air sample survey, radio active waste processing and record retention requirements are per plant procedures and regulatory requirements. Shielding and administrative requirements for designing a modification to an existing design or a new lab/hot cell is subject to in-depth review and approval by Radiation Safety Committee. Each department has a Dose Reduction Subcommittee which meets periodically to discuss if any changes in procedures or facility can be made to decrease the dose. The subcommittee also trends the dose to ensure it is trending downward. Even though 99 Mo/ 99m TC generators are manufactured at the facility, majority of the dose is from cyclotron maintenance

  13. Annual monitoring and surveillance report for Piqua Nuclear Power Facility, Piqua, Ohio

    International Nuclear Information System (INIS)

    Mosho, G.D.

    1991-12-01

    This report discusses the decommissioned Piqua Nuclear Power Facility which is located in Piqua, Ohio near the Greater Miami River. The Facility was built by the US Atomic Energy Commission (now U. S. Department of Energy) and was operated from 1963 to 1966. The reactor was retired prior to 1970 and the facility was leased to the city of Piqua for use as offices and equipment storage. In December 1991, a radiological survey was done of the facility to document its radiological condition. The data show that all radiological parameters measured were essentially the same as that found in the natural environment. The only exception was that low levels of radioactive contamination were detected in one drain on the 56.5 ft elevation, but the radiation exposure rate in that area was also typical of natural background

  14. The Zwicky Transient Facility: Overview and Commissioning Activities

    Science.gov (United States)

    Graham, Matthew; Zwicky Transient Facility (ZTF) Project Team

    2018-01-01

    The Zwicky Transient Facility (ZTF) is the first of a new generation of LSST-scope sky surveys to be realized. It will employ a 47 square degree field-of-view camera mounted on the Samuel Oschin 48-inch Schmidt telescope at Palomar Observatory to scan more than 3750 square degrees an hour to a depth of 20.5 – 21 mag. This will lead to unprecedented discovery rates for transients – a young supernova less than 24 hours after its explosion each night as well as rarer and more exotic sources. Repeated imaging of the Northern sky (including the Galactic Plane) will produce a photometric variability catalog with nearly 300 observations each year, ideal for studies of variable stars, binaries, AGN, and asteroids. ZTF represents a significant increase in scale relative to previous surveys in terms of both data volume and data complexity. It will be the first survey to produce one million alerts a night and the first to have a trillion row data archive. We will present an overview of the survey and its challenges and describe recent commissioning activities.

  15. Survey of radioactive contamination of foodstuffs

    Energy Technology Data Exchange (ETDEWEB)

    Lee, W. R.; Lee, C. W.; Choi, G. S.; Cho, Y. H.; Kang, M. J.; Cheong, K. H.; Kim, H. R.; Kwak, J. Y

    2005-11-15

    The purpose of this study is to survey and assess radioactive contamination of foodstuffs in order to reduce the probability of intake of contaminated foodstuffs. Based on survey and assessment, final goal is to improve the public health by radiation protection. Sampled foodstuffs items are collected from the markets : one group are imported foodstuffs and the other group are domestic foodstuffs producted around nuclear facilities. After pretreatments such as drying, ashing, and homogenization, all samples were analyzed by gamma spectrometer system. The {sup 137}Cs radionuclide was only measured among the regulation radionuclides ({sup 137}Cs, {sup 134}Cs, {sup 131}I) of food code. All radionuclides of the domestic foodstuffs collected around nuclear facilities were below Minimum Detectable Activity (MDA). But the activity concentrations of Inonotus obliquus (Chaga mushooms) from Russia ranged up to 171.27 (average value : 36.65) Bq/kg-fresh. In the case of blueberry jam, the radioactivity of {sup 137}Cs is higher than expected value. Other samples are below MDA except some spices. Based on the previous and present results, it should be strengthen to survey for Inontus obliquus (Chaga mushooms), of which the radioactivity shows the range from MDA up to 800.01 Bq/kg-fresh. It should assess the public radiation exposure via food chain because it has the excess provability of the maximum permitted level of food code, which is regulation of KFDA. The development method based on international standard would be used at radioactive analysis as well as education of practical workers and it could be applied as the basis data for amending the analysis method of food code. Our country only surveys gamma emitting radionuclides till now but international organization or foreign countries for example EU survey alpha and beta emitting radionuclides as well as gamma emitting radionuclides. So our country should also research necessity of survey for alpha and beta emitting

  16. Access to Sanitation Facilities among Nigerian Households: Determinants and Sustainability Implications

    Directory of Open Access Journals (Sweden)

    Ismaila Rimi Abubakar

    2017-04-01

    Full Text Available Access to improved sanitation facilities is key to the socioeconomic wellbeing and sustainable development of any society. This study examines access to sanitation facilities in Nigeria and explores the socioeconomic and locational factors that influence the type of facility used by households. The study utilizes cross-sectional data from the 2013 Nigeria Demographic and Health Survey, and employs descriptive and inferential statistics for data analyses. The results indicated that 44.2% of households used various kinds of pit latrines, followed by toilets that flush to septic tanks (10.3%. While only 5.3% of the respondents used toilets that connect to sewer systems, about a third (31.5% lacked sanitation facility and the remaining 8.7% used other types of sanitation facilities. Results from chi-square analysis and ANOVA revealed significant statistical differences between the type of sanitation facility households used and their place of residence, geopolitical zone, ethnicity, educational attainment and wealth. Multivariate regression results indicated that the type of household sanitation facility is significantly associated with the mentioned factors as well as household size, gender of the head of the household, type of water sources, number of rooms and access to electricity. Age of the head of the household and type of cooking fuel used were not significant. The study concludes by underscoring the implications of using unimproved sanitation facilities on human health and environmental sustainability.

  17. 2MASS - The 2 Micron All Sky Survey

    Science.gov (United States)

    Kleinmann, S. G.

    1992-01-01

    This paper describes a new sky survey to be carried out in three wavebands, J(1.25 m), H(1.65 m), and K(2.2 m). The limiting sensitivity of the survey, 10 sigma detection of point sources with K not greater than 14 mag, coupled with its all-sky coverage, were selected primarily to support studies of the large-scale structure of the Milky Way and the Local Universe. The survey requires construction of a pair of observing facilities, one each for the Northern and Southern Hemispheres. Operations are scheduled to begin in 1995. The data will begin becoming publicly available soon thereafter.

  18. Mineral facilities of Northern and Central Eurasia

    Science.gov (United States)

    Baker, Michael S.; Elias, Nurudeen; Guzman, Eric; Soto-Viruet, Yadira

    2010-01-01

    This map displays almost 900 records of mineral facilities within the countries that formerly constituted the Union of Soviet Socialist Republics (USSR). Each record represents one commodity and one facility type at a single geographic location. Facility types include mines, oil and gas fields, and plants, such as refineries, smelters, and mills. Common commodities of interest include aluminum, cement, coal, copper, gold, iron and steel, lead, nickel, petroleum, salt, silver, and zinc. Records include attributes, such as commodity, country, location, company name, facility type and capacity (if applicable), and latitude and longitude geographical coordinates (in both degrees-minutes-seconds and decimal degrees). The data shown on this map and in table 1 were compiled from multiple sources, including (1) the most recently available data from the U.S. Geological Survey (USGS) Minerals Yearbook (Europe and Central Eurasia volume), (2) mineral statistics and information from the USGS Minerals Information Web site (http://minerals.usgs.gov/minerals/pubs/country/europe.html), and (3) data collected by the USGS minerals information country specialists from sources, such as statistical publications of individual countries, annual reports and press releases of operating companies, and trade journals. Data reflect the most recent published table of industry structure for each country at the time of this publication. Additional information is available from the country specialists listed in table 2

  19. National Survey of Substance Abuse Treatment Services (N-SSATS-2007)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Survey of Substance Abuse Treatment Services (N-SSATS) is designed to collect information from all facilities in the United States, both public and...

  20. National Survey of Substance Abuse Treatment Services (N-SSATS-2004)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Survey of Substance Abuse Treatment Services (N-SSATS) is designed to collect information from all facilities in the United States, both public and...

  1. National Survey of Substance Abuse Treatment Services (N-SSATS-2013)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Survey of Substance Abuse Treatment Services (N-SSATS) is designed to collect information from all facilities in the United States, both public and...

  2. National Survey of Substance Abuse Treatment Services (N-SSATS-2010)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Survey of Substance Abuse Treatment Services (N-SSATS) is designed to collect information from all facilities in the United States, both public and...

  3. National Survey of Substance Abuse Treatment Services (N-SSATS-2014)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Survey of Substance Abuse Treatment Services (N-SSATS) is designed to collect information from all facilities in the United States, both public and...

  4. National Survey of Substance Abuse Treatment Services (N-SSATS-2012)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Survey of Substance Abuse Treatment Services (N-SSATS) is designed to collect information from all facilities in the United States, both public and...

  5. National Survey of Substance Abuse Treatment Services (N-SSATS-2003)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Survey of Substance Abuse Treatment Services (N-SSATS) is designed to collect information from all facilities in the United States, both public and...

  6. National Survey of Substance Abuse Treatment Services (N-SSATS-2006)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Survey of Substance Abuse Treatment Services (N-SSATS) is designed to collect information from all facilities in the United States, both public and...

  7. National Survey of Substance Abuse Treatment Services (N-SSATS-2000)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Survey of Substance Abuse Treatment Services (N-SSATS) is designed to collect information from all facilities in the United States, both public and...

  8. National Survey of Substance Abuse Treatment Services (N-SSATS-2002)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Survey of Substance Abuse Treatment Services (N-SSATS) is designed to collect information from all facilities in the United States, both public and...

  9. National Survey of Substance Abuse Treatment Services (N-SSATS-2008)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Survey of Substance Abuse Treatment Services (N-SSATS) is designed to collect information from all facilities in the United States, both public and...

  10. National Survey of Substance Abuse Treatment Services (N-SSATS-2009)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Survey of Substance Abuse Treatment Services (N-SSATS) is designed to collect information from all facilities in the United States, both public and...

  11. National Survey of Substance Abuse Treatment Services (N-SSATS-2005)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Survey of Substance Abuse Treatment Services (N-SSATS) is designed to collect information from all facilities in the United States, both public and...

  12. National Survey of Substance Abuse Treatment Services (N-SSATS-2011)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Survey of Substance Abuse Treatment Services (N-SSATS) is designed to collect information from all facilities in the United States, both public and...

  13. Transplutonium elements - a literature survey

    International Nuclear Information System (INIS)

    Sivaramakrishnan, C.K.; Jadhav, A.V.

    1974-01-01

    The report surveys reported work on the discovery of transplutonium elements and their production through various methods like bombardment of heavy elements with charged ions, successive neutron captures on heavy elements in reactors and multiple neutron captures by heavy elements during nuclear explosions. Estimated yields of transplutonium elements in special targets irradiated in reactors, and also as byproducts from spent power reactor fuels are quoted. Various chemical procedures adopted for recovery of these elements from irradiated target and also from power reactor fuel reprocessing streams are described. A brief survey of shielded facilities available at various centres for transplutonium programmes is also included. Major uses of some of these heavy elements are described. (author)

  14. User Support of Electron Irradiation Facility

    International Nuclear Information System (INIS)

    Park, S. H.; Cha, H. K.; Lee, B. C.

    2007-06-01

    The KAERI (Korean Atomic Energy Research Institute) high-power electron beam irradiation facility, operating at the energies between 0.3 MeV and 10 MeV,has provided irradiation services to users in industries, universities, and institutes via 'Project of utilization and cooperation of users of a large research facility' since 2004. A great attraction of many researchers, almost 750 persons so far according to surveys, to e-beam irradiation technology as well as the growth of participants on Workshop on Electron Beam Applications from 121 to 176 indicate the increase of demands of irradiation service. Comparing to the cases of advanced nations in this area, such as America, Japan, China, and Russia, Korea is relatively much behind in radiation technology. It is mainly due to the lack of governmental supports and investments. Active support and investment on construction and operation of electron beam user facilities would be principal factors on developments of advanced technologies. In this project, we would like to satisfy users' requests by developing the effective managing and operating system for prompt services, processes, and QA and to ultimately assist users to create additional new results, by maximizing the utilization of all available resources and activating the developments of technologies of electron beam processing

  15. The rule on granting subsidies for survey of hot drainage influences

    International Nuclear Information System (INIS)

    1977-01-01

    The rule is based on the prescriptions of the Law Concerning Proper Budget Enforcement on Subsidies and its Enforcement Order. These rules apply to the granting subsidies provided for by the Enforcement Order for the Special Account Law for Measures Promoting Power Source Development. Terms are defined, such as nuclear power generating facilities; arrangement work for equipments for surveying hot drainage influences; work of preliminary survey of hot drainage; work of surveying hot drainage influences; establishments, etc. The Minister of International Trade and Industry delivers the subsidies for all or a part of the expenses necessary for arrangement work of equipments for surveying hot drainage influences, work of preliminary survey of hot drainage and work of surveying hot drainage influences to the prefectures where nuclear power generating facilities have been or are to be set up, or their neighboring prefectures. Terms of delivery concerning an establishment vary from two years to four years according to the kinds of such subsidies. Limits of the subsidies concerning an establishment range from 10 million yen to 2.5 million yen. The applicant prefecture files the application to the Minister of International Trade and Industry. The Minister examines such applications, and notifies his decision to the applicants. Conditions on delivery, reports submitted by receivers of the subsidies and other matters related are specified. (Okada, K.)

  16. Regional Comparison of Enteral Nutrition-Related Admission Policies in Skilled Nursing Facilities.

    Science.gov (United States)

    Burgermaster, Marissa; Slattery, Eoin; Islam, Nafeesa; Ippolito, Paul R; Seres, David S

    2016-06-01

    Nursing home admission policies are one driver of increased and earlier gastrostomy placement, a procedure that is not always medically or ethically indicated among patients needing short-term nutrition support. This important clinical decision should be based upon patient prognosis, goals, and needs. We compared nursing home enteral nutrition-related admission policies in New York City and other regions of the United States. We also explored motivations for these policies. We conducted a telephone survey with skilled nursing facility administrators in New York City and a random sample of facilities throughout the United States about enteral nutrition-related admission policies. Survey data were matched with publically available data about facility characteristics from the Centers for Medicare and Medicaid Services. The relationship between facility location and admission policies was described with regression models. Reasons for these policies were thematically analyzed. New York City nursing homes were significantly less likely to admit patients with nasogastric feeding tubes than were nursing homes nationwide, after we controlled for facility characteristics (odds ratio = 0.111; 95% CI, 0.032-0.344). Reasons for refusing nasogastric tubes fell into 5 categories: safety, capacity, policy, perception of appropriate level of care, and patient quality of life. Our findings indicate that enteral nutrition-related admission policies vary greatly between nursing homes in New York City and nationwide. Many administrators cited safety and policy as factors guiding their institutional policies and practices, despite a lack of evidence. This gap in research, practice, and policy has implications for quality and cost of care, length of hospital stay, and patient morbidity and mortality. © 2016 American Society for Parenteral and Enteral Nutrition.

  17. The Role of Distance and Quality on Facility Selection for Maternal and Child Health Services in Urban Kenya.

    Science.gov (United States)

    Escamilla, Veronica; Calhoun, Lisa; Winston, Jennifer; Speizer, Ilene S

    2018-02-01

    Universal access to health care requires service availability and accessibility for those most in need of maternal and child health services. Women often bypass facilities closest to home due to poor quality. Few studies have directly linked individuals to facilities where they sought maternal and child health services and examined the role of distance and quality on this facility choice. Using endline data from a longitudinal survey from a sample of women in five cities in Kenya, we examine the role of distance and quality on facility selection for women using delivery, facility-based contraceptives, and child health services. A survey of public and private facilities offering reproductive health services was also conducted. Distances were measured between household cluster location and both the nearest facility and facility where women sought care. A quality index score representing facility infrastructure, staff, and supply characteristics was assigned to each facility. We use descriptive statistics to compare distance and quality between the nearest available facility and visited facility among women who bypassed the nearest facility. Facility distance and quality comparisons were also stratified by poverty status. Logistic regression models were used to measure associations between the quality and distance to the nearest facility and bypassing for each outcome. The majority of women bypassed the nearest facility regardless of service sought. Women bypassing for delivery traveled the furthest and had the fewest facility options near their residential cluster. Poor women bypassing for delivery traveled 4.5 km further than non-poor women. Among women who bypassed, two thirds seeking delivery and approximately 46% seeking facility-based contraception or child health services bypassed to a public hospital. Both poor and non-poor women bypassed to higher quality facilities. Our findings suggest that women in five cities in Kenya prefer public hospitals and are

  18. Regulations and financing for decommissioning of nuclear facilities

    International Nuclear Information System (INIS)

    Kumakura, Osamu

    1981-01-01

    The purpose of this report is to survey the French legislation concerning the decommissioning of nuclear facilities and the method of financing for it. There is no clause in French regulations, which states any specific criterion or licensing procedure for the proper decommissioning. The legal problems in this domain are treated within the general regulation system on atomic energy. The decommissioning of nuclear facilities is carried out in accordance with the licensing procedure for constructing nuclear facilities or the permission procedure for operating them, according to the ''Decree on nuclear installations, 1963''. The works for the final shut-down and decommissioning are regarded as the modification to the safety report or the general operation instructions, and new permit is required. In the case that the radioactivity of substances after decommissioning is above the criteria of the Decree, 1963, the new license is required. In the case of below the criteria, the facilities are governed by the ''Act on installations classified for environmental protection, 1976''. The ''Decree on general radiation protection, 1966'', the ''Decree on radiation protection of workers in nuclear installations, 1975'', the ''Ministerial order on transport of dangerous materials, 1945'', and two ministerial orders on radioactive effluent discharge, 1974, are applied to the decommissioning works. (Kako, I.)

  19. Radiological survey results at Porter Street City Park, Beverly, Massachusetts (VB026)

    International Nuclear Information System (INIS)

    Foley, R.D.; Johnson, C.A.

    1992-08-01

    At the request of the US Department of Energy (DOE), a team from Oak Ridge National Laboratory conducted a radiological survey at the Porter Street City Park, Beverly, Massachusetts. The survey was performed in May 1991. The purpose of the survey was to determine if uranium from work performed under government contract at the former Ventron facility had migrated off-site to neighboring areas. The survey included a surface gamma scan and the collection of soil samples for radionuclide analyses. Results of the survey demonstrated no radionuclide concentrations or radiation measurements in excess of the DOE Formerly Utilized Sites Remedial Action Program guidelines

  20. Shielding design for positron emission tomography facility

    International Nuclear Information System (INIS)

    Abdallah, I.I.

    2007-01-01

    With the recent advent of readily available tracer isotopes, there has been marked increase in the number of hospital-based and free-standing positron emission tomography (PET) clinics. PET facilities employ relatively large activities of high-energy photon emitting isotopes, which can be dangerous to the health of humans and animals. This coupled with the current dose limits for radiation worker and members of the public can result in shielding requirements. This research contributes to the calculation of the appropriate shielding to keep the level of radiation within an acceptable recommended limit. Two different methods were used including measurements made at selected points of an operating PET facility and computer simulations by using Monte Carlo Transport Code. The measurements mainly concerned the radiation exposure at different points around facility using the survey meter detectors and Thermoluminescent Dosimeters (TLD). Then the set of manual calculation procedures were used to estimate the shielding requirements for a newly built PEF facility. The results from the measurement and the computer simulation were compared to the results obtained from the set manual calculation procedure. In general, the estimated weekly dose at the points of interest is lower than the regulatory limits for the little company of Mary Hospital. Furthermore, the density and the HVL for normal strength concrete and clay bricks are almost similar. In conclusion, PET facilities present somewhat different design requirements and are more likely to require additional radiation shielding. Therefore, existing shields at the little Company of Mary Hospital are in general found to be adequate and satisfactory and additional shielding was found necessary at the new PET facility in the department of Nuclear Medicine of the Dr. George Mukhari Hospital. By use of appropriate design, by implying specific shielding requirements and by maintaining good operating practices, radiation doses to

  1. RCRA Facilities Assessment (RFA)---Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    1987-03-01

    US Department of Energy (DOE) facilities are required to be in full compliance with all federal and state regulations. In response to this requirement, the Oak Ridge National Laboratory (ORNL) has established a Remedial Action Program (RAP) to provide comprehensive management of areas where past and current research, development, and waste management activities have resulted in residual contamination of facilities or the environment. This report presents the RCRA Facility Assessment (RFA) required to meet the requirements of RCRA Section 3004(u). Included in the RFA are (1) a listing of all sites identified at ORNL that could be considered sources of releases or potential releases; (2) background information on each of these sites, including location, type, size, period of operation, current operational status, and information on observed or potential releases (as required in Section II.A.1 of the RCRA permit); (3) analytical results obtained from preliminary surveys conducted to verify the presence or absence of releases from some of the sites; and (4) ORNL's assessment of the need for further remedial attention

  2. RCRA Facilities Assessment (RFA)---Oak Ridge National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    1987-03-01

    US Department of Energy (DOE) facilities are required to be in full compliance with all federal and state regulations. In response to this requirement, the Oak Ridge National Laboratory (ORNL) has established a Remedial Action Program (RAP) to provide comprehensive management of areas where past and current research, development, and waste management activities have resulted in residual contamination of facilities or the environment. This report presents the RCRA Facility Assessment (RFA) required to meet the requirements of RCRA Section 3004(u). Included in the RFA are (1) a listing of all sites identified at ORNL that could be considered sources of releases or potential releases; (2) background information on each of these sites, including location, type, size, period of operation, current operational status, and information on observed or potential releases (as required in Section II.A.1 of the RCRA permit); (3) analytical results obtained from preliminary surveys conducted to verify the presence or absence of releases from some of the sites; and (4) ORNL`s assessment of the need for further remedial attention.

  3. RCRA Facilities Assessment (RFA)---Oak Ridge National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    1987-03-01

    US Department of Energy (DOE) facilities are required to be in full compliance with all federal and state regulations. In response to this requirement, the Oak Ridge National Laboratory (ORNL) has established a Remedial Action Program (RAP) to provide comprehensive management of areas where past and current research, development, and waste management activities have resulted in residual contamination of facilities or the environment. This report presents the RCRA Facility Assessment (RFA) required to meet the requirements of RCRA Section 3004(u). Included in the RFA are (1) a listing of all sites identified at ORNL that could be considered sources of releases or potential releases; (2) background information on each of these sites, including location, type, size, period of operation, current operational status, and information on observed or potential releases (as required in Section II.A.1 of the RCRA permit); (3) analytical results obtained from preliminary surveys conducted to verify the presence or absence of releases from some of the sites; and (4) ORNL's assessment of the need for further remedial attention.

  4. Aerial radiological survey of the Shoreham Nuclear Power Station and surrounding area Brookhaven, New York

    International Nuclear Information System (INIS)

    1984-03-01

    An aerial radiological survey was performed over the area surrounding the Shoreham Nuclear Power Station during 5 to 9 June 1983. The survey, which covered an area of 338 square kilometers (131 square miles), also encompassed the entire Brookhaven National Laboratory (BNL) facility. The highest radiation exposure rate, over 1 milliroentgen per hour (mR/h), was inferred from data measured directly over the BNL facility. This detected activity was due to the presence of cobalt-58, cobalt-60 and cesium-137, which was consistent with normal BNL operations. With the exception of the BNL facility, the only detected man-made radioactivity was found near a cottage in Moriches, New York and was due to the presence of cobalt-60. For the remainder of the survey area, the inferred radiation exposure rates varied generally from 6 to 12 microroentgens per hour (μR/h). The reported exposure rate values include an estimated cosmic ray contribution of 3.7 μR/h. Ground-based measurements, conducted concurrently with the aerial survey, were compared to the inferred aerial results. Pressurized ionization chamber readings and a group of soil samples were acquired from five locations within the survey area. The exposure rate values obtained from these measurements were consistent with those inferred from the aerial results. 11 references, 12 figures, 3 tables

  5. Delivering information: A descriptive study of Australian women’s information needs for decision-making about birth facility

    Directory of Open Access Journals (Sweden)

    Thompson Rachel

    2012-06-01

    Full Text Available Abstract Background Little information is known about what information women want when choosing a birth facility. The objective of this study was to inform the development of a consumer decision support tool about birth facility by identifying the information needs of maternity care consumers in Queensland, Australia. Methods Participants were 146 women residing in both urban and rural areas of Queensland, Australia who were pregnant and/or had recently given birth. A cross-sectional survey was administered in which participants were asked to rate the importance of 42 information items to their decision-making about birth facility. Participants could also provide up to ten additional information items of interest in an open-ended question. Results On average, participants rated 30 of the 42 information items as important to decision-making about birth facility. While the majority of information items were valued by most participants, those related to policies about support people, other women’s recommendations about the facility, freedom to choose one’s preferred position during labour and birth, the aesthetic quality of the facility, and access to on-site neonatal intensive care were particularly widely valued. Additional items of interest frequently focused on postnatal care and support, policies related to medical intervention, and access to water immersion. Conclusions The women surveyed had significant and diverse information needs for decision-making about birth facility. These findings have immediate applications for the development of decision support tools about birth facility, and highlight the need for tools which provide a large volume of information in an accessible and user-friendly format. These findings may also be used to guide communication and information-sharing by care providers involved in counselling pregnant women and families about their options for birth facility or providing referrals to birth facilities.

  6. Nuclear Energy Center Site Survey, 1975. Executive summary

    International Nuclear Information System (INIS)

    1976-01-01

    The Nuclear Energy Center Site Survey is a study of a potential alternative siting approach for nuclear power and fuel-cycle facilities, an approach that would cluster sizable groups of such facilities on a relatively small number of sites. The largest aggregation of reactors on a single site being planned today is four, and this quad is assumed (for comparative study purposes) to be the typical dispersed site by the year 2000. Three basic types of nuclear energy centers are considered: power-plant centers, consisting of 10 to 40 nuclear electric generating units of 1200-megawatt electric capacity each; fuel-cycle centers, consisting of fuel reprocessing plants, mixed-oxide fuel fabrication facilities, and radioactive waste management facilities; and combined centers, containing both power plants and fuel-cycle facilities. The results of the general site-location screening efforts are shown on a United States map that shows the locations of large areas identified as likely to contain suitable candidate sites for power NECs, on the basis of four coarse screening criteria: water resources, seismic activity, population density, and statutory excluded lands

  7. Generic Overview of the Status of Characterization Surveys and Guidance for Decommissioning

    International Nuclear Information System (INIS)

    Abu Eid, Rateb Boby

    2012-01-01

    This paper presents an overview of several topical areas pertaining to characterization and survey for decommissioning, including: U.S. NRC regulatory requirements for decommissioning and survey; a description of the decommissioning processes particularly role of characterization and survey; characterization survey types and NRC categorization of decommissioning groups; status of U.S. characterization survey guidance; and overview of key characterization and survey Issues. The specific topical areas are briefly discussed below: - The paper addresses the U.S. NRC requirements under 10 CFR Part 20, Subpart E - 'Radiological Criteria for License Termination', and final status surveys requirements under 10 CFR 20.1501(a). Other requirements under 10CFR Parts 50.75, 50.82, 51.53, and 51.95) as well as, reporting and record keeping for decommissioning planning will be outlined. The paper also discusses NRC general decommissioning process for materials and fuel cycle facilities, as well as, for power reactor facilities. - Strategy and planning for decommissioning using the data quality objectives (DQO) approach and its seven step process will be presented in some detail. - The US NRC 'Surveys and Site Investigation Process' as described in NUREG 1757 and categorization of 'Decommissioning Groups' in the context of characterization and survey needs will be addressed. - The paper briefly outlines methodologies, approaches, and status of U.S. multi-agency key guidance documents such as MARSSIM (NUREG-1575), MARSAME (NUREG- 1575, Supp.1), and more recently, the NRC Subsurface Guidance NUREG/CR 7021. - Dose modeling and software development/update in support of radiological survey and characterization for derivation of derived concentration guideline levels. - Lessons Learned from Regulatory 'Reviews of Survey Plans' particularly attributes of survey plans, common survey issues, and key aspects for decommissioning success are discussed in the paper. (author)

  8. Parental views on acute otitis media (AOM) and its therapy in children--results of an exploratory survey in German childcare facilities.

    Science.gov (United States)

    Kautz-Freimuth, Sibylle; Redaèlli, Marcus; Samel, Christina; Civello, Daniele; Altin, Sibel V; Stock, Stephanie

    2015-12-01

    Acute otitis media (AOM) is one of the main reasons for medical consultation and antibiotic use during childhood. Although 80% of AOM cases are self-limiting, antibiotic prescription is still high, either for physician- or for parent-related factors. This study aims to identify parental knowledge about, beliefs and attitudes towards, and experiences with AOM and its therapy and thus to gain insights into parents' perspectives within the German health care system. An exploratory survey was conducted among German-speaking parents of children aged 2 to 7 years who sent their children to a childcare facility. Childcare facilities were recruited by convenience sampling in different urban and rural sites in Germany, and all parents with children at those facilities were invited to participate. Data were evaluated using descriptive statistical analyses. One-hundred-thirty-eight parents participated. Of those, 75.4% (n = 104) were AOM-experienced and 75.4% (n = 104) had two or more children. Sixty-six percent generally agree that bacteria cause AOM. 20.2% generally agree that viruses cause AOM. 30.5% do not generally agree that viruses cause AOM. Eight percent generally agree that AOM resolves spontaneously, whereas 53.6% do not generally agree. 92.5% generally (45.7%) and partly (42.8%) agree that AOM needs antibiotic treatment. With respect to antibiotic effects, 56.6% generally agree that antibiotics rapidly relieve earache. 60.1% generally agree that antibiotics affect the gastrointestinal tract and 77.5% generally agree that antibiotics possibly become ineffective after frequent use. About 40% generally support and about 40% generally reject a "wait-and-see" strategy for AOM treatment. Parental-reported experiences reveal that antibiotics are by far more often prescribed (70.2%) than actively requested by parents (26.9%). Parental views on AOM, its therapy, and antibiotic effects reveal uncertainties especially with respect to causes, the natural course of the disease

  9. Computing Facilities for AI: A Survey of Present and Near-Future Options

    OpenAIRE

    Fahlman, Scott

    1981-01-01

    At the recent AAAI conference at Stanford, it became apparent that many new AI research centers are being established around the country in industrial and governmental settings and in universities that have not paid much attention to AI in the past. At the same time, many of the established AI centers are in the process of converting from older facilities, primarily based on Decsystem-10 and Decsystem-20 machines, to a variety of newer options. At present, unfortunately, there is no simple an...

  10. Patient-driven resource planning of a health care facility evacuation.

    Science.gov (United States)

    Petinaux, Bruno; Yadav, Kabir

    2013-04-01

    The evacuation of a health care facility is a complex undertaking, especially if done in an immediate fashion, ie, within minutes. Patient factors, such as continuous medical care needs, mobility, and comprehension, will affect the efficiency of the evacuation and translate into evacuation resource needs. Prior evacuation resource estimates are 30 years old. Utilizing a cross-sectional survey of charge nurses of the clinical units in an urban, academic, adult trauma health care facility (HCF), the evacuation needs of hospitalized patients were assessed periodically over a two-year period. Survey data were collected on 2,050 patients. Units with patients having low continuous medical care needs during an emergency evacuation were the postpartum, psychiatry, rehabilitation medicine, surgical, and preoperative anesthesia care units, the Emergency Department, and Labor and Delivery Department (with the exception of patients in Stage II labor). Units with patients having high continuous medical care needs during an evacuation included the neonatal and adult intensive care units, special procedures unit, and operating and post-anesthesia care units. With the exception of the neonate group, 908 (47%) of the patients would be able to walk out of the facility, 492 (25.5%) would require a wheelchair, and 530 (27.5%) would require a stretcher to exit the HCF. A total of 1,639 patients (84.9%) were deemed able to comprehend the need to evacuate and to follow directions; the remainder were sedated, blind, or deaf. The charge nurses also determined that 17 (6.9%) of the 248 adult intensive care unit patients were too ill to survive an evacuation, and that in 10 (16.4%) of the 61 ongoing surgery cases, stopping the case was not considered to be safe. Heath care facilities can utilize the results of this study to model their anticipated resource requirements for an emergency evacuation. This will permit the Incident Management Team to mobilize the necessary resources both within

  11. Impact of Methane Leak Detection and Repair Programs: Determining Pre- and Post-Survey Emissions Profiles

    Science.gov (United States)

    Roda-Stuart, D. J.; Ravikumar, A. P.; Brandt, A. R.

    2017-12-01

    Upstream production sites contribute 66 percent of methane emissions from natural gas systems [1]. Being a major greenhouse gas, many states and national governments are developing policies to reduce methane emissions. Recent policies to address this issue have focused on periodic leak detection and repair (LDAR) surveys at oil and gas facilities [2]. Development of effective LDAR surveys is complicated by two things. First, available empirical data makes it difficult to say anything definitive about which facilities or equipment are most prone to leakage. Second, there has been little research done on post-LDAR emissions profiles and the time evolution of leaks, two measures that would influence survey effectiveness and cost. In this work, we present data from LDAR operations conducted at upstream facilities of a Canadian natural gas producer. Surveys were done by an outside contractor using a FLIR optical gas imaging camera. Twenty-two well pads, five processing plants, and three compressor stations were surveyed, of which four, two, and one, respectively, were revisited. We examine the persistence of leaks over time periods ranging from 6 months to 15 months following the initial LDAR survey. Developing pre- and post-survey emission factors and distributions can help inform survey schedules and help update and monitor mitigation targets. Furthermore, we analyze the effect of weather conditions, survey frequency, and operational characteristics of equipment on the effectiveness of the LDAR program. For instance, we find that a survey done at the commissioning of a gas processing plant yields both safety and emissions reduction benefits. Using leak frequency distributions, we identify components and equipment that require more frequent and targeted surveying. Insights from this study can assist businesses and policy makers develop methane mitigation policies aimed at maximizing the marginal benefits of LDAR programs. [1] Inventory of U.S. Greenhouse Gas Emissions

  12. Potential reuse of petroleum-contaminated soil: A directory of permitted recycling facilities

    International Nuclear Information System (INIS)

    Rosenthal, S.; Wolf, G.; Avery, M.; Nash, J.H.

    1992-06-01

    Soil contaminated by virgin petroleum products leaking from underground storage tanks is a pervasive problem in the United States. Economically feasible disposal of such soil concerns the responsible party (RP), whether the RP is one individual small business owner, a group of owners, or a large multinational corporation. They may need a starting point in their search for an appropriate solution, such as recycling. The report provides initial assistance in two important areas. First it discusses four potential recycling technologies that manufacture marketable products from recycled petroleum-contaminated soil: the hot mix asphalt process, the cold mix asphalt system, cement production, and brick manufacturing. The report also presents the results of a project survey designed to identify recycling facilities. It lists recycling facilities alphabetically by location within each state, organized by U.S. Environmental Protection Agency (EPA) Region. The report also includes detailed addresses, recycling locations, telephone numbers, and contacts for these facilities. The scope of the project limits listings to fixed facilities or small mobile facility owners that recycle soil contaminated by virgin petroleum products into marketable commodities. It does not address site-specific or commercial hazardous waste remediation facilities

  13. Insight into implementation of facility-based integrated management of childhood illness strategy in a rural district of Sindh, Pakistan.

    Science.gov (United States)

    Pradhan, Nousheen Akber; Rizvi, Narjis; Sami, Neelofar; Gul, Xaher

    2013-07-05

    Integrated management of childhood illnesses (IMCI) strategy has been proven to improve health outcomes in children under 5 years of age. Pakistan, despite being in the late implementation phase of the strategy, continues to report high under-five mortality due to pneumonia, diarrhea, measles, and malnutrition - the main targets of the strategy. The study determines the factors influencing IMCI implementation at public-sector primary health care (PHC) facilities in Matiari district, Sindh, Pakistan. An exploratory qualitative study with an embedded quantitative strand was conducted. The qualitative part included 16 in-depth interviews (IDIs) with stakeholders which included planners and policy makers at a provincial level (n=5), implementers and managers at a district level (n=3), and IMCI-trained physicians posted at PHC facilities (n=8). Quantitative part included PHC facility survey (n=16) utilizing WHO health facility assessment tool to assess availability of IMCI essential drugs, supplies, and equipments. Qualitative content analysis was used to interpret the textual information, whereas descriptive frequencies were calculated for health facility survey data. The major factors reported to enhance IMCI implementation were knowledge and perception about the strategy and need for separate clinic for children aged under 5 years as potential support factors. The latter can facilitate in strategy implementation through allocated workforce and required equipments and supplies. Constraint factors mainly included lack of clear understanding of the strategy, poor planning for IMCI implementation, ambiguity in defined roles and responsibilities among stakeholders, and insufficient essential supplies and drugs at PHC centers. The latter was further substantiated through health facilities' survey findings, which indicated that none of the facilities had 100% stock of essential supplies and drugs. Only one out of all 16 surveyed facilities had 75% of the total supplies

  14. Nuclear energy center site survey: fuel cycle studies

    International Nuclear Information System (INIS)

    1976-05-01

    Background information for the Nuclear Regulatory Commission Nuclear Energy Center Site Survey is presented in the following task areas: economics of integrated vs. dispersed nuclear fuel cycle facilities, plutonium fungibility, fuel cycle industry model, production controls and failure contingencies, environmental impact, waste management, emergency response capability, and feasibility evaluations

  15. Facility effluent monitoring plan determinations for the 400 Area facilities

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1991-09-01

    This Facility Effluent Monitoring Plan determination resulted from an evaluation conducted for the Westinghouse Hanford Company 400 Area facilities on the Hanford Site. The Facility Effluent Monitoring Plan determinations have been prepared in accordance with A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans. Two major Westinghouse Hanford Company facilities in the 400 Area were evaluated: the Fast Flux Test Facility and the Fuels Manufacturing and examination Facility. The determinations were prepared by Westinghouse Hanford Company. Of these two facilities, only the Fast Flux Test Facility will require a Facility Effluent Monitoring Plan. 7 refs., 5 figs., 4 tabs

  16. Where there is no toilet: water and sanitation environments of domestic and facility births in Tanzania.

    Directory of Open Access Journals (Sweden)

    Lenka Benova

    Full Text Available Inadequate water and sanitation during childbirth are likely to lead to poor maternal and newborn outcomes. This paper uses existing data sources to assess the water and sanitation (WATSAN environment surrounding births in Tanzania in order to interrogate whether such estimates could be useful for guiding research, policy and monitoring initiatives.We used the most recent Tanzania Demographic and Health Survey (DHS to characterise the delivery location of births occurring between 2005 and 2010. Births occurring in domestic environments were characterised as WATSAN-safe if the home fulfilled international definitions of improved water and improved sanitation access. We used the 2006 Service Provision Assessment survey to characterise the WATSAN environment of facilities that conduct deliveries. We combined estimates from both surveys to describe the proportion of all births occurring in WATSAN-safe environments and conducted an equity analysis based on DHS wealth quintiles and eight geographic zones.42.9% (95% confidence interval: 41.6%-44.2% of all births occurred in the woman's home. Among these, only 1.5% (95% confidence interval: 1.2%-2.0% were estimated to have taken place in WATSAN-safe conditions. 74% of all health facilities conducted deliveries. Among these, only 44% of facilities overall and 24% of facility delivery rooms were WATSAN-safe. Combining the estimates, we showed that 30.5% of all births in Tanzania took place in a WATSAN-safe environment (range of uncertainty 25%-42%. Large wealth-based inequalities existed in the proportion of births occurring in domestic environments based on wealth quintile and geographical zone.Existing data sources can be useful in national monitoring and prioritisation of interventions to improve poor WATSAN environments during childbirth. However, a better conceptual understanding of potentially harmful exposures and better data are needed in order to devise and apply more empirical definitions of

  17. Where there is no toilet: water and sanitation environments of domestic and facility births in Tanzania.

    Science.gov (United States)

    Benova, Lenka; Cumming, Oliver; Gordon, Bruce A; Magoma, Moke; Campbell, Oona M R

    2014-01-01

    Inadequate water and sanitation during childbirth are likely to lead to poor maternal and newborn outcomes. This paper uses existing data sources to assess the water and sanitation (WATSAN) environment surrounding births in Tanzania in order to interrogate whether such estimates could be useful for guiding research, policy and monitoring initiatives. We used the most recent Tanzania Demographic and Health Survey (DHS) to characterise the delivery location of births occurring between 2005 and 2010. Births occurring in domestic environments were characterised as WATSAN-safe if the home fulfilled international definitions of improved water and improved sanitation access. We used the 2006 Service Provision Assessment survey to characterise the WATSAN environment of facilities that conduct deliveries. We combined estimates from both surveys to describe the proportion of all births occurring in WATSAN-safe environments and conducted an equity analysis based on DHS wealth quintiles and eight geographic zones. 42.9% (95% confidence interval: 41.6%-44.2%) of all births occurred in the woman's home. Among these, only 1.5% (95% confidence interval: 1.2%-2.0%) were estimated to have taken place in WATSAN-safe conditions. 74% of all health facilities conducted deliveries. Among these, only 44% of facilities overall and 24% of facility delivery rooms were WATSAN-safe. Combining the estimates, we showed that 30.5% of all births in Tanzania took place in a WATSAN-safe environment (range of uncertainty 25%-42%). Large wealth-based inequalities existed in the proportion of births occurring in domestic environments based on wealth quintile and geographical zone. Existing data sources can be useful in national monitoring and prioritisation of interventions to improve poor WATSAN environments during childbirth. However, a better conceptual understanding of potentially harmful exposures and better data are needed in order to devise and apply more empirical definitions of WATSAN

  18. Automatic Estimation of the Radiological Inventory for the Dismantling of Nuclear Facilities

    International Nuclear Information System (INIS)

    Garcia-Bermejo, R.; Felipe, A.; Gutierrez, S.; Salas, E.; Martin, N.

    2008-01-01

    The estimation of the radiological inventory of Nuclear Facilities to be dismantled is a process that included information related with the physical inventory of all the plant and radiological survey. Estimation of the radiological inventory for all the components and civil structure of the plant could be obtained with mathematical models with statistical approach. A computer application has been developed in order to obtain the radiological inventory in an automatic way. Results: A computer application that is able to estimate the radiological inventory from the radiological measurements or the characterization program has been developed. In this computer applications has been included the statistical functions needed for the estimation of the central tendency and variability, e.g. mean, median, variance, confidence intervals, variance coefficients, etc. This computer application is a necessary tool in order to be able to estimate the radiological inventory of a nuclear facility and it is a powerful tool for decision taken in future sampling surveys

  19. Survey of existing underground openings for in-situ experimental facilities

    International Nuclear Information System (INIS)

    Wollenberg, H.; Graf, A.; Strisower, B.; Korbin, G.

    1981-07-01

    In an earlier project, a literature search identified 60 underground openings in crystalline rock capable of providing access for an in-situ experimental facility to develop geochemical and hydrological techniques for evaluating sites for radioactive waste isolation. As part of the current project, discussions with state geologists, owners, and operators narrowed the original group to 14. Three additional sites in volcanic rock and one site in granite were also identified. Site visits and application of technical criteria, including the geologic and hydrologic settings and depth, extent of the rock unit, condition, and accessibility of underground workings, determined four primary candidate sites: the Helms Pumped Storage Project in grandiodorite of the Sierra Nevada, California; the Tungsten Queen Mine in Precambrian granodiorite of the North Carolina Piedmont; the Mount Hope Mine in Precambrian granite and gneiss of northern New Jersey; and the Minnamax Project in the Duluth gabbro complex of northern Minnesota

  20. Hospital to Post-Acute Care Facility Transfers: Identifying Targets for Information Exchange Quality Improvement.

    Science.gov (United States)

    Jones, Christine D; Cumbler, Ethan; Honigman, Benjamin; Burke, Robert E; Boxer, Rebecca S; Levy, Cari; Coleman, Eric A; Wald, Heidi L

    2017-01-01

    Information exchange is critical to high-quality care transitions from hospitals to post-acute care (PAC) facilities. We conducted a survey to evaluate the completeness and timeliness of information transfer and communication between a tertiary-care academic hospital and its related PAC facilities. This was a cross-sectional Web-based 36-question survey of 110 PAC clinicians and staff representing 31 PAC facilities conducted between October and December 2013. We received responses from 71 of 110 individuals representing 29 of 31 facilities (65% and 94% response rates). We collapsed 4-point Likert responses into dichotomous variables to reflect completeness (sufficient vs insufficient) and timeliness (timely vs not timely) for information transfer and communication. Among respondents, 32% reported insufficient information about discharge medical conditions and management plan, and 83% reported at least occasionally encountering problems directly related to inadequate information from the hospital. Hospital clinician contact information was the most common insufficient domain. With respect to timeliness, 86% of respondents desired receipt of a discharge summary on or before the day of discharge, but only 58% reported receiving the summary within this time frame. Through free-text responses, several participants expressed the need for paper prescriptions for controlled pain medications to be sent with patients at the time of transfer. Staff and clinicians at PAC facilities perceive substantial deficits in content and timeliness of information exchange between the hospital and facilities. Such deficits are particularly relevant in the context of the increasing prevalence of bundled payments for care across settings as well as forthcoming readmissions penalties for PAC facilities. Targets identified for quality improvement include structuring discharge summary information to include information identified as deficient by respondents, completion of discharge summaries

  1. Radiation and contamination survey of the Terengganu offshore facilities

    International Nuclear Information System (INIS)

    Amran Abd Majid; Sukiman Sarmani

    1995-01-01

    It is well known that low specific activity of technologically enhanced naturally occurring radioactive materials (LSA TENORM) such as U-238 and Th-232 and their daughter products have been associated with oil and gas fields. For the period of October 1988 and August 1989 UKM personels were involved in conducting the radiation and contamination survey at several offshore platforms in Terengganu. The results showed that the maximum external and internal radiation levels was 0. 45 μSv/hr whereas the maximum surface contamination level was 0. 124 Bq cm sup -2. These results indicate that the levels were below the level prescribed by the Malaysian Atomic Energy Licensing Board. However, several measures still need to be considered for the safety of the workers and will be discussed in this paper. (author)

  2. Patterns of admission to acute psychiatric in-patient facilities: a national survey in Italy.

    Science.gov (United States)

    Preti, A; Rucci, P; Santone, G; Picardi, A; Miglio, R; Bracco, R; Norcio, B; de Girolamo, G

    2009-03-01

    A proper understanding of patterns of care represents a crucial step in improving clinical decision making and enhancing service provision. Only a few studies, however, have explored global patterns of psychiatric admissions nationwide, and none have been undertaken in Italy. Sociodemographic, clinical and treatment-related information was collected for 1577 patients admitted to 130 public and 36 private in-patient facilities in Italy during an index period in the year 2004. All patients were also rated using the 24-item Brief Psychiatric Rating Scale (BPRS) and the Personal and Social Performance (PSP) rating scales. Non-affective psychoses (36%) were the most common diagnoses and accounted to a large extent for compulsory admissions. Private facilities were more likely to admit patients with organic mental disorders and substance abuse/dependence and less likely to admit patients with non-affective psychoses. Overall, 77.8% of patients had been receiving treatment by a mental health professional in the month prior to admission. In 54% of cases, the admission was solicited by patients' family members. The main factors preceding admission were impairment in work or social functioning, social withdrawal, and conflict with family members. Agitation, delusions and/or hallucinations, and the presence of multiple problems were associated with compulsory admissions, whereas depressive and anxiety symptoms were associated with voluntary admissions. In a mixed, public-private psychiatric care system, like the Italian one, public and private facilities admit patients with widely different clinical characteristics and needs. Family support represents an important resource for most patients, and interventions specifically addressed to relieving family burden are warranted.

  3. Survey report of FY 1997 on the environmentally acceptable coal utilization system feasibility survey. Dispatch of engineers; 1997 nendo chosa hokokusho. Kankyo chowagata sekitan riyo system kanosei chosa (senmonka haken)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    The purpose of this survey is to improve the coal utilization technology and to contribute to the environmental protection. Through long-term dispatch of experts for the coal utilization technology, coal utilization facilities are surveyed at the sites, advises for coal utilization technology and environmental protection technology are given, and useful information for the cooperation with the partner country are exchanged. In this fiscal year, experts were dispatched to Thailand in addition to China, to conduct cooperative surveys, technical exchanges and seminars with both countries. Experts for desulfurization technology, circulating fluidized bed boilers, effective coal ash utilization technology, and coal preparation technology were dispatched to various places in China. Among various model projects conducted in China, examples of model projects for simplified desulfurizer introduction, circulating fluidized bed boiler introduction, and briquette production facility introduction were presented at seminars held at two cities in China. Experts for briquette production technology and circulating fluidized bed boiler technology were dispatched to Thailand, to conduct cooperative surveys and technical exchanges. 22 figs., 9 tabs.

  4. General service and child immunization-specific readiness assessment of healthcare facilities in two selected divisions in Bangladesh.

    Science.gov (United States)

    Shawon, Md Shajedur Rahman; Adhikary, Gourab; Ali, Md Wazed; Shamsuzzaman, Md; Ahmed, Shahabuddin; Alam, Nurul; Shackelford, Katya A; Woldeab, Alexander; Lim, Stephen S; Levine, Aubrey; Gakidou, Emmanuela; Uddin, Md Jasim

    2018-01-25

    Service readiness of health facilities is an integral part of providing comprehensive quality healthcare to the community. Comprehensive assessment of general and service-specific (i.e. child immunization) readiness will help to identify the bottlenecks in healthcare service delivery and gaps in equitable service provision. Assessing healthcare facilities readiness also helps in optimal policymaking and resource allocation. A health facility survey was conducted between March 2015 and December 2015 in two purposively selected divisions in Bangladesh; i.e. Rajshahi division (high performing) and Sylhet division (low performing). A total of 123 health facilities were randomly selected from different levels of service, both public and private, with variation in sizes and patient loads from the list of facilities. Data on various aspects of healthcare facility were collected by interviewing key personnel. General service and child immunization specific service readiness were assessed using the Service Availability and Readiness Assessment (SARA) manual developed by World Health Organization (WHO). The analyses were stratified by division and level of healthcare facilities. The general service readiness index for pharmacies, community clinics, primary care facilities and higher care facilities were 40.6%, 60.5%, 59.8% and 69.5%, respectively in Rajshahi division and 44.3%, 57.8%, 57.5% and 73.4%, respectively in Sylhet division. Facilities at all levels had the highest scores for basic equipment (ranged between 51.7% and 93.7%) and the lowest scores for diagnostic capacity (ranged between 0.0% and 53.7%). Though facilities with vaccine storage capacity had very high levels of service readiness for child immunization, facilities without vaccine storage capacity lacked availability of many tracer items. Regarding readiness for newly introduced pneumococcal conjugate vaccine (PCV) and inactivated polio vaccine (IPV), most of the surveyed facilities reported lack of

  5. Control survey of normal reference ranges adopted for serum thyroxine binding globulin, thyroxine, triiodothyronine in Japan

    International Nuclear Information System (INIS)

    Sugisaki, Hajime; Kameyama, Mayumi; Shibata, Kyoko

    1985-01-01

    A survey using questionnaires was made on 152 facilities from July through September 1984 to examine normal reference ranges of serum thyroxine binding globulin (TBG), thyroxine (TT 4 ), and triiodothyronine (TT 3 ). Normal reference ranges of TBG were in good agreement with each other, with the exception of four facilities showing high upper limits. An average value of the upper and lower limits in 83 facilities was 13.7 +- 1.9 μg/ml; and the standard deviation was 28.6 +- 2.8 μg/ml. Differences (approximately 10 %) in coefficient of variation were comparable to those (5.7-9.6 %) obtained from the previous survey. There were approximately 10 % differences in coefficient of variation for both TT 4 and TT 3 . (Namekawa, K.)

  6. A Survey of Hadron Therapy Accelerator Technologies.

    Energy Technology Data Exchange (ETDEWEB)

    PEGGS,S.; SATOGATA, T.; FLANZ, J.

    2007-06-25

    Hadron therapy has entered a new age [1]. The number of facilities grows steadily, and 'consumer' interest is high. Some groups are working on new accelerator technology, while others optimize existing designs by reducing capital and operating costs, and improving performance. This paper surveys the current requirements and directions in accelerator technology for hadron therapy.

  7. Family Planning Supply Environment in Kinshasa, DRC: Survey Findings and Their Value in Advancing Family Planning Programming

    Science.gov (United States)

    Kayembe, Patrick; Babazadeh, Saleh; Dikamba, Nelly; Akilimali, Pierre; Hernandez, Julie; Binanga, Arsene; Bertrand, Jane T

    2015-01-01

    Background: Modern contraceptive prevalence was 14.1% in 2007 in Kinshasa, the capital city of the Democratic Republic of the Congo (DRC). Yet virtually nothing was known about the family planning supply environment. Methods: Three surveys of health facilities were conducted in 2012, 2013, and 2014 to determine the number, spatial distribution, and attributes of sites providing family planning services. The 2012 and 2013 surveys aimed to identify the universe of family planning facilities while obtaining a limited set of data on “readiness” to provide family planning services (defined as having at least 3 modern methods, at least 1 person training in family planning in the last 3 years, and an information system to track distribution of products to clients) and output (measured by couple-years of protection, or CYP). In contrast, the 2014 survey, conducted under the umbrella of the Performance Monitoring and Accountability 2020 (PMA2020) project, was based on 2-stage cluster sampling. This article provides detailed analysis of the 2012 and 2013 surveys, including bivariate and multivariate analysis of correlates of readiness to provide services and of output. Results: We identified 184 health facilities that reported providing at least 1 contraceptive method in 2012 and 395 facilities in 2013. The percentage of sites defined as “ready” to provide services increased from 44.1% in 2012 to 63.3% in 2013. For the 3-month period between January and March 2013, facilities distributed between 0 and 879.2 CYP (mean, 39.7). Nearly half (49%) of the CYP was attributable to implants, followed by IUDs (24%), CycleBeads (11%), and injectables (8%). In 2013, facilities supported by PEPFAR (n = 121) were more likely than other facilities to be rated as ready to provide services (Pplanning implementing agencies (Pplanning in the DRC in many ways, including mobilizing partners to increase contraceptive access and increasing donor investment in family planning in the DRC

  8. Supernovae and cosmology with future European facilities.

    Science.gov (United States)

    Hook, I M

    2013-06-13

    Prospects for future supernova surveys are discussed, focusing on the European Space Agency's Euclid mission and the European Extremely Large Telescope (E-ELT), both expected to be in operation around the turn of the decade. Euclid is a 1.2 m space survey telescope that will operate at visible and near-infrared wavelengths, and has the potential to find and obtain multi-band lightcurves for thousands of distant supernovae. The E-ELT is a planned, general-purpose ground-based, 40-m-class optical-infrared telescope with adaptive optics built in, which will be capable of obtaining spectra of type Ia supernovae to redshifts of at least four. The contribution to supernova cosmology with these facilities will be discussed in the context of other future supernova programmes such as those proposed for DES, JWST, LSST and WFIRST.

  9. Factors affecting the use of patient survey data for quality improvement in the Veterans Health Administration

    Directory of Open Access Journals (Sweden)

    Davies Elizabeth A

    2011-12-01

    Full Text Available Abstract Background Little is known about how to use patient feedback to improve experiences of health care. The Veterans Health Administration (VA conducts regular patient surveys that have indicated improved care experiences over the past decade. The goal of this study was to assess factors that were barriers to, or promoters of, efforts to improve care experiences in VA facilities. Methods We conducted case studies at two VA facilities, one with stable high scores on inpatient reports of emotional support between 2002 and 2006, and one with stable low scores over the same period. A semi-structured interview was used to gather information from staff who worked with patient survey data at the study facilities. Data were analyzed using a previously developed qualitative framework describing organizational, professional and data-related barriers and promoters to data use. Results Respondents reported more promoters than barriers to using survey data, and particularly support for improvement efforts. Themes included developing patient-centered cultures, quality improvement structures such as regular data review, and training staff in patient-centered behaviors. The influence of incentives, the role of nursing leadership, and triangulating survey data with other data on patients' views also emerged as important. It was easier to collect data on current organization and practice than those in the past and this made it difficult to deduce which factors might influence differing facility performance. Conclusions Interviews with VA staff provided promising examples of how systematic processes for using survey data can be implemented as part of wider quality improvement efforts. However, prospective studies are needed to identify the most effective strategies for using patient feedback to improve specific aspects of patient-centered care.

  10. The 8th questionnaire survey report of safety control in nuclear medicine

    International Nuclear Information System (INIS)

    2008-01-01

    A questionnaire survey on safety of nuclear medicine studies was conducted under the subcommittee for radionuclide imaging and nuclear medicine technology of Japan Radioisotope Association to promote patient safety. Questionnaires were sent to 1300 hospitals and 21 clinical laboratories in Japan with 1034 facilities responded (78.3%). Sixty percents of the workers in the facilities were nuclear medicine technologists. Medical doctors comprised 20% of the workers, but 32% in the university hospitals. The number of laboratory technologists decreased in all categories of the facilities. Composite PET/CT scanners increased sharply, whereas 2-detector and 3-detector imaging systems decreased. Regular maintenance was performed in approximately 80% of the SPECT imaging systems, while the single head imaging systems were maintained less frequently. Filmless systems were employed in 25.3% of all of the facilities responded, with the higher rate in the university hospitals. The number of accidents and incidents in the facilities decreased. Falls on floor and fall from an examination bed were reported. The nuclear medicine technologists were concerned about safety mechanism of imaging systems, and dimension and height of examination beds. They also wanted prompt supply of safety information and easy interconnectivity among different data of various vendors' systems. The results of this survey may be a valuable source of information on safety of nuclear medicine procedures. (author)

  11. HIV/AIDS related commodities supply chain management in public health facilities of Addis Ababa, Ethiopia: a cross-sectional survey.

    Science.gov (United States)

    Berhanemeskel, Eyerusalem; Beedemariam, Gebremedhin; Fenta, Teferi Gedif

    2016-01-01

    A wide range of pharmaceutical products are needed for diagnosis, treatment, and prevention of HIV/AIDS. However, interrupted supplies and stock-outs are the major challenges in the supply chain of ARV medicines and related commodities. The aim of this study was to assess the supply chain management of HIV/AIDS related commodities in public health facilities of Addis Ababa, Ethiopia. A descriptive cross-sectional survey complemented by qualitative method was conducted in 24 public health facilities (4 hospitals and 20 health centers). A semi-structured questionnaire and observation check list were used to collect data on HIV/AIDS related service, reporting and ordering; receiving, transportation and storage condition of ARV medicines and test kits; and supportive supervision and logistics management information system. In addition, in-depth interview with flexible probing techniques was used to complement the quantitative data with emphasis to the storage condition of ARV medicines and test kits. Quantitative data was analyzed using SPSS version-20. Analysis of qualitative data involved rigorous reading of transcripts in order to identify key themes and data was analyzed using thematic approach. The study revealed that 16 health centers and one hospital had recorded and reported patient medication record. Six months prior to the study, 14 health centers and 2 hospitals had stopped VCT services for one time or more. Three hospitals and 18 health centers claimed to have been able to submit the requisition and report concerning ARV medicines to Pharmaceutical Fund and Supply Agency according to the specific reporting period. More than three-fourth of the health centers had one or more emergency order of ARV medicines on the day of visit, while all of hospitals had emergency order more than 3 times within 6 months prior to the study. All of the hospitals and nearly half of the health centers had an emergency order of test kits more than 3 times in the past 6

  12. Radiological survey of Ingalls Shipbuilding Division, Pascagoula, Mississippi, and environs

    International Nuclear Information System (INIS)

    Fowler, T.W.; Windham, S.T.; Callis, R.S.; Phillips, C.R.

    1983-09-01

    This report presents results of the survey conducted by EERF personnel to assess environmental radioactivity remaining from operations of nuclear-powered vessels at Ingalls Shipyard, Pascagoula, Mississippi. Since Ingalls Shipyard will no longer build or service nuclear powered ships and has completed the decommissioning of the nuclear support facilities, an additional purpose of the survey was to determine if there is any remaining radioactivity from previous operations which could contribute to significant population exposure

  13. National Survey of Substance Abuse Treatment Services (N-SSATS-1997-2011)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The National Survey of Substance Abuse Treatment Services (N-SSATS) is designed to collect information from all facilities in the United States, both public and...

  14. Assistance Dogs: Historic Patterns and Roles of Dogs Placed by ADI or IGDF Accredited Facilities and by Non-Accredited U.S. Facilities.

    Science.gov (United States)

    Walther, Sandra; Yamamoto, Mariko; Thigpen, Abigail Paige; Garcia, Anaissa; Willits, Neil H; Hart, Lynette A

    2017-01-01

    Dogs' roles to support people with disabilities are increasing. Existing U.S. laws and regulations pertaining to the use of dogs for people with disabilities are only minimally enforced. Pushback legislation against some aspects of uses of assistance dogs currently is being passed or proposed in several states. Further, the U.S. Department of the Army and the Veterans' Administration support only dogs trained by an Assistance Dogs International (ADI) or International Guide Dog Federation (IGDF) accredited facility. Lacking a mandatory national process for screening the selection, training, and placement of assistance dogs with persons who have disabilities, the U.S. offers a creative but confusing opportunity for people to train their own dogs for any disability. While no U.S. surveillance system monitors assistance dogs, other countries generally have a legislated or regulatory process for approving assistance dogs or a cultural convention for obtaining dogs from accredited facilities. We conducted an online survey investigating current demographics of assistance dogs placed in 2013 and 2014 with persons who have disabilities, by facilities worldwide that are associated with ADI or IGDF and by some non-accredited U.S. facilities. Placement data from ADI and IGDF facilities revealed that in most countries aside from the U.S., guide dogs were by far the main type of assistance dog placed. In the U.S., there were about equal numbers of mobility and guide dogs placed, including many placed by large older facilities, along with smaller numbers of other types of assistance dogs. In non-accredited U.S. facilities, psychiatric dogs accounted for most placements. Dogs for families with an autistic child were increasing in all regions around the world. Of dog breeds placed, accredited facilities usually mentioned Labrador Retrievers and Golden Retrievers, and sometimes, German Shepherd Dogs. The facilities bred their dogs in-house, or acquired them from certain breeders

  15. Neutron tomography: A survey and some recent applications

    International Nuclear Information System (INIS)

    Rhodes, E.A.; Morman, J.A.; McClellan, G.C.

    1990-01-01

    A survey is given of recent developments in selected areas of neutron tomography, within the context of several applications Argonne is involved in, including high penetration of reactor-fuel bundles in thick containers (involving Transient Reactor Test Facility (TREAT) and NRAD facilities), dual-energy hydrogen imaging (performed at Intense Pulsed Neutron Source), dynamic coarse-resolution emission tomography of reactor fuel under test (a proposed modification to the TREAT hodoscope), and an associated-particle system that uses neutron flight-time to electronically collimate transmitted neutrons and to tomographically image nuclides identified by reaction gamma-rays. 23 refs., 12 figs

  16. Implementation of Best Practices in Obesity Prevention in Child Care Facilities: The Arizona Empower Program, 2013-2015.

    Science.gov (United States)

    Papa, Jillian; Agostinelli, Joan; Rodriguez, Gertrudes; Robinson, Deborah

    2017-09-07

    Obesity is a major health concern in every US age group. Approximately one in 4 children in Arizona's Special Supplemental Nutrition Program for Women, Infants, and Children is overweight or obese. The Arizona Department of Health Services developed the Empower program to promote healthy environments in licensed child care facilities. The program consists of 10 standards, including one standard for each of these 5 areas: physical activity and screen time, breastfeeding, fruit juice and water, family-style meals, and staff training. The objective of this evaluation was to determine the level of implementation of these 5 Empower standards. A self-assessment survey was completed from July 2013 through June 2015 by 1,850 facilities to evaluate the level of implementation of 5 Empower standards. We calculated the percentage of facilities that reported the degree to which they implemented each standard and identified common themes in comments recorded in the survey. All facilities reported either full or partial implementation of the 5 standards. Of 1,678 facilities, 21.7% (n = 364) reported full implementation of all standards, and 78.3% (n = 1,314) reported at least partial implementation. Staff training, which has only one component, had the highest level of implementation: 77.4% (n = 1,299) reported full implementation. Only 44.0% (n = 738) reported full implementation of the standard on a breastfeeding-friendly environment. Arizona child care facilities have begun to implement the Empower program, but facilities will need more education, technical assistance, and support in some areas to fully implement the program.

  17. A Survey of Technologies Supporting Virtual Project Based Learning

    DEFF Research Database (Denmark)

    Dirckinck-Holmfeld, Lone

    2002-01-01

    This paper describes a survey of technologies and to what extent they support virtual project based learning. The paper argues that a survey of learning technologies should be related to concrete learning tasks and processes. Problem oriented project pedagogy (POPP) is discussed, and a framework...... for evaluation is proposed where negotiation of meaning, coordination and resource management are identified as the key concepts in virtual project based learning. Three e-learning systems are selected for the survey, Virtual-U, Lotus Learningspace and Lotus Quickplace, as each system offers different strategies...... for e-learning. The paper concludes that virtual project based learning may benefit from facilities of all these systems....

  18. The survey regarding sports and exercise of Keio University students

    OpenAIRE

    野口, 和行; 近藤, 明彦; 加藤, 大仁; 山内, 賢

    2009-01-01

    We conducted a survey of "College Students' Attitude toward Sports and Exercise" using students of all facilities and grades in Keio University. The purpose of this report is 1) to compare the amount of sports and exercise across facilities and grades, 2) to analyze frequencies, amount of time, and attitudes regarding different types of sports and exercise activities, 3) to examine attitudes toward and reasoning of no exercise, and 4) to examine their preference of activities in their free ti...

  19. Nuclear Energy Center Site Survey, 1975. Part I. Summary and conclusions

    International Nuclear Information System (INIS)

    1976-01-01

    The Nuclear Energy Center Site Survey is a study of a potential siting approach for projected power and fuel-cycle facilities that would cluster sizable groups of such facilities on a relatively small number of sites, as contrasted with current dispersed siting practices. Three basic types of nuclear energy centers (NECs) are considered: power-plant centers, involving ten to forty units of 1200-megawatt electric capacity each; fuel-cycle centers, involving fuel reprocessing plants, mixed-oxide fuel fabrication facilities, and high-level and transuranic radioactive waste management facilities, with a capacity corresponding to the fuel throughput of power plants with a total capacity of approximately 50,000 to 300,000 MWe; and combined centers, containing both power plants and fuel cycle facilities in representative possible combinations. Included among the principal issues considered in evaluation of feasibility of nuclear energy centers are dissipation of the waste heat from the power-generating facilities; transmission system design, reliability, and economics; radiological impact; and environmental impact

  20. Neutron fluence measurement in nuclear facilities

    International Nuclear Information System (INIS)

    Camacho L, M.E.

    1997-01-01

    The objective of present work is to determine the fluence of neutrons in nuclear facilities using two neutron detectors designed and built at Instituto Nacional de Investigaciones Nucleares (ININ), Mexico. The two neutron detectors are of the passive type, based on solid state nuclear tracks detectors (SSNTD). One of the two neutron detectors was used to determine the fluence distribution of the ports at the nuclear research reactor TRIGA Mark III, which belongs to ININ. In these facilities is important to know the neutron fluence distribution characteristic to carried out diverse kind of research activities. The second neutron detector was employed in order to carry out environmental neutron surveillance. The detector has the property to separate the thermal, intermediate and fast components of the neutron fluence. This detector was used to measure the neutron fluence at hundred points around the primary container of the first Mexican Nuclear Power plant 'Laguna Verde'. This last detector was also used to determine the neutron fluence in some points of interest, around and inside a low scattering neutron room at the 'Centro de Metrologia de Radiaciones Ionizantes' of the ININ, to know the background neutron field produced by the neutron sources used there. The design of the two neutron detector and the results obtained for each of the surveying facilities, are described in this work. (Author)

  1. Interstellar extinction from photometric surveys: application to four high-latitude areas

    Science.gov (United States)

    Malkov, Oleg; Karpov, Sergey; Kilpio, Elena; Sichevsky, Sergey; Chulkov, Dmitry; Dluzhnevskaya, Olga; Kovaleva, Dana; Kniazev, Alexei; Mickaelian, Areg; Mironov, Alexey; Murthy, Jayant; Sytov, Alexey; Zhao, Gang; Zhukov, Aleksandr

    2018-04-01

    Information on interstellar extinction and dust properties may be obtained from modern large photometric surveys data. Virtual Observatory facilities allow users to make a fast and correct cross-identification of objects from various surveys. It yields a multicolor photometry data on detected objects and makes it possible to estimate stellar parameters and calculate interstellar extinction. A 3D extinction map then can be constructed. The method was applied to 2MASS, SDSS, GALEX and UKIDSS surveys. Results for several high-latitude areas are obtained, compared with independent sources and discussed here.

  2. Interstellar extinction from photometric surveys: application to four high-latitude areas

    Directory of Open Access Journals (Sweden)

    Malkov Oleg

    2018-04-01

    Full Text Available Information on interstellar extinction and dust properties may be obtained from modern large photometric surveys data. Virtual Observatory facilities allow users to make a fast and correct cross-identification of objects from various surveys. It yields a multicolor photometry data on detected objects and makes it possible to estimate stellar parameters and calculate interstellar extinction. A 3D extinction map then can be constructed. The method was applied to 2MASS, SDSS, GALEX and UKIDSS surveys. Results for several high-latitude areas are obtained, compared with independent sources and discussed here.

  3. A questionnaire survey of medical physicist and quality manager for radiation therapy

    International Nuclear Information System (INIS)

    Nishio, Teiji; Ashino, Yasuo; Onishi, Hiroshi

    2008-01-01

    A questionnaire survey of medical physicists and quality managers for radiation therapy was performed by the Japanese Society for Therapeutic Radiology and Oncology (JASTRO) Future Planning Committee. We mailed the questionnaire to 726 radiotherapy facilities with the answers returned from 353 radiotherapy facilities. The result showed 178 facilities were staffed by radiotherapy workers who were licensed medical physicists or quality managers. A staff of 289 was licensed radiotherapy workers. Most of the staff were radiotherapy technologists. Quality control for radiation therapy was rated satisfactory according to each facility's assessment. Radiation therapy of high quality requires continued education of medical physicists and quality managers, in addition to keeping up with times for quality control. (author)

  4. Smoke-Free Medical Facility Campus Legislation: Support, Resistance, Difficulties and Cost

    Directory of Open Access Journals (Sweden)

    J. Gary Wheeler

    2009-01-01

    Full Text Available Although medical facilities restrict smoking inside, many people continue to smoke outside, creating problems with second-hand smoke, litter, fire risks, and negative role modeling. In 2005, Arkansas passed legislation prohibiting smoking on medical facility campuses. Hospital administrators (N=113 were surveyed pre- and post-implementation. Administrators reported more support and less difficulty than anticipated. Actual cost was 10-50% of anticipated cost. Few negative effects and numerous positive effects on employee performance and retention were reported. The results may be of interest to hospital administrators and demonstrate that state legislation can play a positive role in facilitating broad health-related policy change.

  5. A New Automated Instrument Calibration Facility at the Savannah River Site

    International Nuclear Information System (INIS)

    Polz, E.; Rushton, R.O.; Wilkie, W.H.; Hancock, R.C.

    1998-01-01

    The Health Physics Instrument Calibration Facility at the Savannah River Site in Aiken, SC was expressly designed and built to calibrate portable radiation survey instruments. The facility incorporates recent advances in automation technology, building layout and construction, and computer software to improve the calibration process. Nine new calibration systems automate instrument calibration and data collection. The building is laid out so that instruments are moved from one area to another in a logical, efficient manner. New software and hardware integrate all functions such as shipping/receiving, work flow, calibration, testing, and report generation. Benefits include a streamlined and integrated program, improved efficiency, reduced errors, and better accuracy

  6. The use of music in aged care facilities: A mixed-methods study.

    Science.gov (United States)

    Garrido, Sandra; Dunne, Laura; Perz, Janette; Chang, Esther; Stevens, Catherine J

    2018-02-01

    Music is frequently used in aged care, being easily accessible and cost-effective. Research indicates that certain types of musical engagement hold greater benefits than others. However, it is not clear how effectively music is utilized in aged care facilities and what the barriers are to its further use. This study used a mixed-methods paradigm, surveying 46 aged care workers and conducting in-depth interviews with 5, to explore how music is used in aged care facilities in Australia, staff perceptions of the impact of music on residents, and the barriers to more effective implementation of music in aged care settings.

  7. Modeling the Perceptions and Preferences of Pedestrians on Crossing Facilities

    Directory of Open Access Journals (Sweden)

    Hongwei Guo

    2014-01-01

    Full Text Available Pedestrian’s street-crossing behaviour has a significant effect on traffic performance and safety. The crossing behaviour is determined by human factors and environmental factors. Aiming at examining the pedestrian perceptions toward crossing facilities and preferences for crossing locations, an observational study of pedestrian crossing behaviour at urban street is conducted. The perceptions and preferences of pedestrians are collected using stated preference technique. A specific questionnaire is designed to conduct the stated preference survey. A multinomial logit model is proposed to describe the perceptions and preferences of pedestrians on crossing facilities and locations. The sensitivity analysis is performed to discuss the influence of various factors on crossing behaviour. Then the relationship between crossing locations and crossing distances is analyzed by a new proposed method. With the theoretical analysis, the engineering solutions considering pedestrian behaviour are suggested. The results are helpful to design human-centered crossing facilities in urban traffic.

  8. Insight into implementation of facility-based integrated management of childhood illness strategy in a rural district of Sindh, Pakistan

    Directory of Open Access Journals (Sweden)

    Nousheen Akber Pradhan

    2013-07-01

    Full Text Available Background: Integrated management of childhood illnesses (IMCI strategy has been proven to improve health outcomes in children under 5 years of age. Pakistan, despite being in the late implementation phase of the strategy, continues to report high under-five mortality due to pneumonia, diarrhea, measles, and malnutrition – the main targets of the strategy. Objective: The study determines the factors influencing IMCI implementation at public-sector primary health care (PHC facilities in Matiari district, Sindh, Pakistan. Design: An exploratory qualitative study with an embedded quantitative strand was conducted. The qualitative part included 16 in-depth interviews (IDIs with stakeholders which included planners and policy makers at a provincial level (n=5, implementers and managers at a district level (n=3, and IMCI-trained physicians posted at PHC facilities (n=8. Quantitative part included PHC facility survey (n=16 utilizing WHO health facility assessment tool to assess availability of IMCI essential drugs, supplies, and equipments. Qualitative content analysis was used to interpret the textual information, whereas descriptive frequencies were calculated for health facility survey data. Results: The major factors reported to enhance IMCI implementation were knowledge and perception about the strategy and need for separate clinic for children aged under 5 years as potential support factors. The latter can facilitate in strategy implementation through allocated workforce and required equipments and supplies. Constraint factors mainly included lack of clear understanding of the strategy, poor planning for IMCI implementation, ambiguity in defined roles and responsibilities among stakeholders, and insufficient essential supplies and drugs at PHC centers. The latter was further substantiated through health facilities’ survey findings, which indicated that none of the facilities had 100% stock of essential supplies and drugs. Only one out of all

  9. Awareness of Racial Disparities in Kidney Transplantation among Health Care Providers in Dialysis Facilities.

    Science.gov (United States)

    Kim, Joyce J; Basu, Mohua; Plantinga, Laura; Pastan, Stephen O; Mohan, Sumit; Smith, Kayla; Melanson, Taylor; Escoffery, Cam; Patzer, Rachel E

    2018-05-07

    Despite the important role that health care providers at dialysis facilities have in reducing racial disparities in access to kidney transplantation in the United States, little is known about provider awareness of these disparities. We aimed to evaluate health care providers' awareness of racial disparities in kidney transplant waitlisting and identify factors associated with awareness. We conducted a cross-sectional analysis of a survey of providers from low-waitlisting dialysis facilities ( n =655) across all 18 ESRD networks administered in 2016 in the United States merged with 2014 US Renal Data System and 2014 US Census data. Awareness of national racial disparity in waitlisting was defined as responding "yes" to the question: "Nationally, do you think that African Americans currently have lower waitlisting rates than white patients on average?" The secondary outcome was providers' perceptions of racial difference in waitlisting at their own facilities. Among 655 providers surveyed, 19% were aware of the national racial disparity in waitlisting: 50% (57 of 113) of medical directors, 11% (35 of 327) of nurse managers, and 16% (35 of 215) of other providers. In analyses adjusted for provider and facility characteristics, nurse managers (versus medical directors; odds ratio, 7.33; 95% confidence interval, 3.35 to 16.0) and white providers (versus black providers; odds ratio, 2.64; 95% confidence interval, 1.39 to 5.02) were more likely to be unaware of a national racial disparity in waitlisting. Facilities in the South (versus the Northeast; odds ratio, 3.05; 95% confidence interval, 1.04 to 8.94) and facilities with a low percentage of blacks (versus a high percentage of blacks; odds ratio, 1.86; 95% confidence interval, 1.02 to 3.39) were more likely to be unaware. One quarter of facilities had >5% racial difference in waitlisting within their own facilities, but only 5% were aware of the disparity. Among a limited sample of dialysis facilities with low

  10. Environmental monitoring for EG and G Idaho facilities at the Idaho National Engineering Laboratory

    International Nuclear Information System (INIS)

    Tkachyk, J.W.; Wright, K.C.; Wilhelmsen, R.N.

    1990-08-01

    This report describes the 1989 environmental-monitoring activities of the Environmental Monitoring Unit of EG ampersand G Idaho, Inc., at EG ampersand G-operated facilities at the Idaho National Engineering Laboratory (INEL). The major facilities monitored include the Radioactive Waste Management Complex, the Waste Experimental Reduction Facility, the Mixed Waste Storage Facility, and two surplus facilities. Additional monitoring activities performed by Environmental Monitoring are also discussed, including drinking-water monitoring and nonradiological liquid-effluent monitoring, as well as data management. The primary purposes of monitoring are to evaluate environmental conditions and to provide and interpret data, in compliance with applicable regulations, to ensure protection of human health and the environment. This report compares 1989 environmental-monitoring data with derived concentration guides and with data from previous years. This report also presents results of sampling performed by the Radiological and Environmental Sciences Laboratory and by the United States Geological Survey. 17 refs., 49 figs., 11 tabs

  11. Long-term performance of structural component of intermediate- and low-level radioactive waste disposal facility

    International Nuclear Information System (INIS)

    Hwang, Joo Ho; Kim, Seong Soo; Lee, Jae Min; Kang, Dong Koo; Yu, Jeong Beom; Lim, Goon Taek

    1998-03-01

    Domestic and foreign requirements with regard to the selection criteria and the performance criteria for structural components of disposal facility were surveyed. Characteristics of presently available cements were studied. Types and characteristics of high performance concrete and construction methods similar to disposal facility are also included in the study. Definitions of the term durability and the limit of the term were surveyed. Literature survey for the important factors affecting the durability and modeling methods to assess durability was performed. Deterioration and crack forming mechanisms were studied. Characteristics of domestic ground water were collected from KAERI data. Experiments were carried out with synthetic ground water to study the reactions between cement and constituents in the ground water. Experiments lasted up to 130 days and penetration of cations and anions was investigated. Ions of importance were Ca 2- . Mg 2- , SO 4 2+ , Cl - . Changes of ionic concentrations and compressive strength after 110 to 130 days of soaking in synthetic ground water with accelerated conditions were measured. Based upon ASTM's standard for accelerated testing, procedures to assess the durability of cement concrete were suggested

  12. Improving water, sanitation and hygiene in health-care facilities, Liberia.

    Science.gov (United States)

    Abrampah, Nana Mensah; Montgomery, Maggie; Baller, April; Ndivo, Francis; Gasasira, Alex; Cooper, Catherine; Frescas, Ruben; Gordon, Bruce; Syed, Shamsuzzoha Babar

    2017-07-01

    The lack of proper water and sanitation infrastructures and poor hygiene practices in health-care facilities reduces facilities' preparedness and response to disease outbreaks and decreases the communities' trust in the health services provided. To improve water and sanitation infrastructures and hygiene practices, the Liberian health ministry held multistakeholder meetings to develop a national water, sanitation and hygiene and environmental health package. A national train-the-trainer course was held for county environmental health technicians, which included infection prevention and control focal persons; the focal persons acted as change agents. In Liberia, only 45% of 701 surveyed health-care facilities had an improved water source in 2015, and only 27% of these health-care facilities had proper disposal for infectious waste. Local ownership, through engagement of local health workers, was introduced to ensure development and refinement of the package. In-county collaborations between health-care facilities, along with multisectoral collaboration, informed national level direction, which led to increased focus on water and sanitation infrastructures and uptake of hygiene practices to improve the overall quality of service delivery. National level leadership was important to identify a vision and create an enabling environment for changing the perception of water, sanitation and hygiene in health-care provision. The involvement of health workers was central to address basic infrastructure and hygiene practices in health-care facilities and they also worked as stimulators for sustainable change. Further, developing a long-term implementation plan for national level initiatives is important to ensure sustainability.

  13. Capabilities for processing shipping casks at spent fuel storage facilities

    International Nuclear Information System (INIS)

    Baker, W.H.; Arnett, L.M.

    1978-01-01

    Spent fuel is received at a storage facility in heavily shielded casks transported either by rail or truck. The casks are inspected, cooled, emptied, decontaminated, and reshipped. The spent fuel is transferred to storage. The number of locations or space inside the building provided to perform each function in cask processing will determine the rate at which the facility can process shipping casks and transfer spent fuel to storage. Because of the high cost of construction of licensed spent fuel handling and storage facilities and the difficulty in retrofitting, it is desirable to correctly specify the space required. In this paper, the size of the cask handling facilities is specified as a function of rate at which spent fuel is received for storage. The minimum number of handling locations to achieve a given throughput of shipping casks has been determined by computer simulation of the process. The simulation program uses a Monte Carlo technique in which a large number of casks are received at a facility with a fixed number of handling locations in each process area. As a cask enters a handling location, the time to process the cask at that location is selected at random from the distribution of process time. Shipping cask handling times are based on experience at the General Electric Storage Facility, Morris, Illinois. Shipping cask capacity is based on the most recent survey available of the expected capability of reactors to handle existing rail or truck casks

  14. Investigating the Importance of Sports Facilities & Staff for Football Fans

    Directory of Open Access Journals (Sweden)

    Pinelopi Athanasopoulou

    2012-01-01

    Full Text Available (a Purpose: This study seeks to investigate the importance of facilities and staff for football fans in Greece. (b Design/methodology/approach: A survey was carried out during two matches of Superleague games with a convenience sample of 312 spectators. A structured questionnaire was used with scales based on previous research. (c Findings: Factor analysis revealed four reliable factor dimensions: facilities design; staff; facilities maintenance, and quick & easy access. Staff and quick & easy access are shown to be the most important dimensions for respondents followed by the other two. Results also indicated that there are significant differences in the importance assigned to these 4 factor dimensions among different levels of age; education; income, and marital status. (d Research limitations/implications: This study is limited to one sport and on a convenience sample of football fans. Future research can validate further these findings and increase their generalisability. (e Practical implications: The results of this study challenge sport managers to manage effectively the design of the stadium; the processes of entry and exit of fans; the environment of the game; and the quality of stadium facilities.

  15. Calibration of dosemeters and survey instruments for photon

    International Nuclear Information System (INIS)

    Alamares, A.L.; Caseria, E.S.

    1995-01-01

    The Philippine Nuclear Research Institute (PNRI), the country's regulatory agency, through its Radiation Protection Unit of the Nuclear Regulations Licensing and Safeguard Division provides the calibration services of nuclear instruments used by various institutions. The periodic calibration and standardization of radiation and protection survey instruments are done to insure correct and valid radiation readings. It is also a regulatory requirement for radiation workers to use only operable and precalibrated survey instruments for their work with radioactive materials. The PNRI maintains and operates the Secondary Standard Dosimetry Laboratory (SSDL). It provides the periodic calibration and standardization of radiation monitoring and protection survey instruments, and also the radiological hazard and performance evaluation surveys of radiotherapy facilities and others. For the calibration of survey instruments, the standard sources of Cs-137 and Co-60 are used. The calibration procedures for survey meters and pocket dosimeters are explained. The clients served are shown. The personnel dosimetry using film badges, the application of ICRU operational quantities, and the problems encountered and recommendations are reported. (K.I.)

  16. Aerial radiological survey of the Lawrence Livermore Laboratory (Livermore, California)

    International Nuclear Information System (INIS)

    Tipton, W.J.

    1977-10-01

    An airborne radiological survey was conducted during August 1975 over several selected sites in the vicinity of Livermore, California. These sites included the Lawrence Livermore Laboratory, Sandia Livermore Laboratories, LLL Site 300, the Livermore Municipal Golf Course, and the City of Livermore's sewage treatment plant. The radiation results were processed specifically for man-made gamma ray activity. All elevated man-made activity observed during the aerial survey was contained within the site boundaries of the three DOE facilities

  17. Turnover of regulated nurses in long-term care facilities.

    Science.gov (United States)

    Chu, Charlene H; Wodchis, Walter P; McGilton, Katherine S

    2014-07-01

    To describe the relationship between nursing staff turnover in long-term care (LTC) homes and organisational factors consisting of leadership practices and behaviours, supervisory support, burnout, job satisfaction and work environment satisfaction. The turnover of regulated nursing staff [Registered Nurses (RNs) and Registered Practical Nurses (RPNs)] in LTC facilities is a pervasive problem, but there is a scarcity of research examining this issue in Canada. The study was conceptualized using a Stress Process model. Distinct surveys were distributed to administrators to measure organisational factors and to regulated nurses to measure personal and job-related sources of stress and workplace support. In total, 324 surveys were used in the linear regression analysis to examine factors associated with high turnover rates. Higher leadership practice scores were associated with lower nursing turnover; a one score increase in leadership correlated with a 49% decrease in nursing turnover. A significant inverse relationship between leadership turnover and nurse turnover was found: the higher the administrator turnover the lower the nurse turnover rate. Leadership practices and administrator turnover are significant in influencing regulated nurse turnover in LTC. Long-term care facilities may want to focus on building good leadership and communication as an upstream method to minimize nurse turnover. © 2013 John Wiley & Sons Ltd.

  18. Patterns of tobacco consumption in food facilities in Riyadh, Saudi Arabia

    Science.gov (United States)

    Mandil, Ahmed; Yamani, Mohammad; BinSaeed, Abdulaziz; Ahmad, Shaffi; Younis, Afnan; Al-Mutlaq, Ahmad; Al-Baqmy, Omar; Al-Rajhi, Abdulaziz

    2014-01-01

    AIM: This study aimed at assessing prevailing patterns and risk factors of tobacco consumption among clients, food handlers and employers of food facilities, in Riyadh, Saudi Arabia. METHODS: A cross-sectional approach to a representative sample of food facilities in Riyadh was used. A sample of 3000 participants included clients (75%); food handlers/hospitality workers (20 %) and employers (5 %). Participants were reached at restaurants, food courts or cafes. A modified version of the WHO-CDC-Global Youth Tobacco Survey questionnaire was used for data collection. RESULTS: The prevalence of tobacco use at food facilities was found to be 40.3 %, of which 74% were customers, 18.8% were food handlers and 7.2% were managers. The consumption of tobacco was higher at restaurants (39.9%), but lowest at food courts of shopping malls. Water pipe (55.3%) was the main consumption type, followed by cigarettes (42.6%) and chewing tobacco (2.1%). Multivariate analysis showed that gender (male), marital status (single), and type of food facility (Estaraha and café/coffee shop) were independent risk factors associated with tobacco use at food facilities. CONCLUSION: Tobacco use is very common in food facilities in Riyadh as reflected by results of our study, especially among single males Saudis. We should build on success encountered in banning smoking in airports, airplanes, shopping malls, market places, educational institutions and healthcare facilities, extending the ban to include food facilities as well. This is important for the health of non-smokers as well as smokers themselves. PMID:24987478

  19. Federal facilities compliance act waste management

    International Nuclear Information System (INIS)

    Bowers, J.; Gates-Anderson, D.; Hollister, R.; Painter, S.

    1999-01-01

    Site Treatment Plans (STPs) developed through the Federal Facilities Compliance Act pose many technical and administrative challenges. Legacy wastes managed under these plans require Land Disposal Restriction (LDR) compliance through treatment and ultimate disposal. Although capacity has been defined for most of the Department of Energy wastes, many waste streams require further characterization and many need additional treatment and handling beyond LDR criteria to be able to dispose of the waste. At Lawrence Livermore National Laboratory (LLNL), the Hazardous Waste Management Division has developed a comprehensive Legacy Waste Program. The program directs work to manage low level and mixed wastes to ensure compliance with nuclear facility rules and its STP. This paper provides a survey of work conducted on these wastes at LLNL. They include commercial waste treatment and disposal, diverse forms of characterization, inventory maintenance and reporting, on-site treatment, and treatability studies. These activities are conducted in an integrated fashion to meet schedules defined in the STP. The processes managing wastes are dynamic due to required integration of administrative, regulatory, and technical concerns spanning the gamut to insure safe proper disposal

  20. A Study on the Representative Sampling Survey for Radionuclide Analysis of RI Waste

    Energy Technology Data Exchange (ETDEWEB)

    Jee, K. Y. [KAERI, Daejeon (Korea, Republic of); Kim, Juyoul; Jung, Gunhyo [FNC Tech. Co., Daejeon (Korea, Republic of)

    2007-07-15

    We developed a quantitative method for attaining a representative sample during sampling survey of RI waste. Considering a source, process, and type of RI waste, the method computes the number of sample, confidence interval, variance, and coefficient of variance. We also systematize the method of sampling survey logically and quantitatively. The result of this study can be applied to sampling survey of low- and intermediate-level waste generated from nuclear power plant during the transfer process to disposal facility.

  1. Results of the radiological verification survey at the former Herring-Hall-Marvin Safe Company, 1550 Grand Boulevard, Hamilton Ohio (HO001V)

    International Nuclear Information System (INIS)

    Murray, M.E.; allred, J.F.; Johnson, C.A.

    1995-11-01

    During the period between the 1940s and early 1950s, the Herring-Hall-Marvin Safe Company, 1550 Grand Boulevard, Hamilton, Ohio, was one company under subcontract to the Manhattan Engineer District (MED), and the Atomic Energy Commission (AEC), the lead agencies in the development of nuclear energy for defense-related projects. The US Department of Energy (DOE) conducted radiological surveys of these sites to evaluate current radiological conditions as part of the Formerly Utilized Sites Remedial Action Program (FUSRAP). In 1988, a radiological survey of the Herring-Hall-Marvin Safe Company facility was conducted, and after small fragments of uranium metal were removed, no beta or gamma radiation above background was detected and the building was dismissed from any additional DOE restrictions. In 1993, it was discovered that a portion of the actual machining work was conducted on the third floor of the facility, located in the southeastern comer of the building. At the request of DOE, this part of the facility was radiologically surveyed by an ORNL survey team to determine whether fixed surface contamination could be found that might exceed the DOE guidelines. Results of this radiological survey indicated 238 U contamination in excess of the DOE criteria for surface contamination, and the site was recommended for remediation. In February and March of 1995, a verification survey of the third floor of the former Herring-Hall-Marvin Safe Company facility by an ORNL survey team was performed in conjunction with decontamination operations conducted under the supervision of Bechtel National Incorporated. The verification survey included gamma scans at the surface and at one meter, alpha and beta-gamma scans for fixed contamination, and smears for transferable contamination

  2. Sheath-lens probe for negative ion detection in reactive plasmas

    International Nuclear Information System (INIS)

    Stamate, E.; Sugai, H.; Takai, O.; Ohe, K.

    2004-01-01

    A method that allows easy and inexpensive detection of negative ions is introduced. The method is based upon the electrostatic lens effect of the sheath layer evolving to a positively biased planar probe that focuses the negative charges to distinct regions on the surface. Trajectories of negative ions inside the sheath are obtained after computing the potential and electric field distribution by solving in three dimensions the nonlinear Poisson equation. The negative ions' flux to square and disk probes is developed in Ar/SF 6 and O 2 plasmas. The method allows negative ion detection with sensitivity higher than that of Langmuir probes

  3. Dance Facilities.

    Science.gov (United States)

    Ashton, Dudley, Ed.; Irey, Charlotte, Ed.

    This booklet represents an effort to assist teachers and administrators in the professional planning of dance facilities and equipment. Three chapters present the history of dance facilities, provide recommended dance facilities and equipment, and offer some adaptations of dance facilities and equipment, for elementary, secondary and college level…

  4. Environmental licensing of nuclear facilities: compatibility of technical competencies

    International Nuclear Information System (INIS)

    Shu, J.; Paiva, R.L.C. de; Mezrahi, A.; Cardoso, E.M.; Aquino, W.P.; Deppe, A.L.; Menezes, R.M.; Prado, V.; Franco, N.M.F.L.; Nouailhetas, Y.; Xavier, A.M.

    1996-01-01

    The Brazilian Nuclear Energy Commission (CNEN) has the technical competency for diagnosing environmental radiological impacts, as well as evaluating the safety and requiring adequate control of the facilities which, due to their activities, represent a potential risk of radiological contamination for the environment. The institution is responsible for emission of radioprotection guidelines, controls and surveys in nuclear safety according to the country's regulations and international recommendations. The methodology to assure the limitation of radiation exposure is consequence from shared control over the nuclear activities, in special the nuclear facilities. According to the Federal Constitution of 1988, the nuclear activities must be under exclusive control of the Union in special related to the nuclear policies, economical, laboral and nuclear safety aspects, while the health and environmental controls of these activities are shared by the Federation, Union, States, Federal District and Counties. The controls related to specific aspects have to be harmonized in such a way to be optimized and effective. In this paper the results of compatibilization of nuclear legislation and environmental legislation are presented aiming to optimize the licensing of nuclear facilities. (author)

  5. Facilities inventory protection for nuclear facilities

    International Nuclear Information System (INIS)

    Schmitt, F.J.

    1989-01-01

    The fact that shut-down applications have been filed for nuclear power plants, suggests to have a scrutinizing look at the scopes of assessment and decision available to administrations and courts for the protection of facilities inventories relative to legal and constitutional requirements. The paper outlines the legal bases which need to be observed if purposeful calculation is to be ensured. Based on the different actual conditions and legal consequences, the author distinguishes between 1) the legal situation of facilities licenced already and 2) the legal situation of facilities under planning during the licencing stage. As indicated by the contents and restrictions of the pertinent provisions of the Atomic Energy Act and by the corresponding compensatory regulation, the object of the protection of facilities inventor in the legal position of the facility owner within the purview of the Atomic Energy Act, and the licensing proper. Art. 17 of the Atomic Energy Act indicates the legislators intent that, once issued, the licence will be the pivotal point for regulations aiming at protection and intervention. (orig./HSCH) [de

  6. Barriers to Shared Use of Indoor and Outdoor Facilities at US Elementary Schools

    Science.gov (United States)

    Turner, Lindsey; Calvert, Hannah G.; Chaloupka, Frank J.

    2018-01-01

    Background: School policies and practices, such as the sharing of school facilities with the surrounding community, support physical activity among students and community members, but are often underutilized. This study examined variations in shared use practices, and associations with perceived barriers. Methods: Surveys were completed by a…

  7. Survey of the measures to be concretely taken for CEV introduction/spread in the region; Chiiki ni okeru CEV donyu fukyu no tame no gutaiteki hosaku ni kansuru chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-03-01

    For the Hanshin/Harima region where CEV introduction/spread are expected and there is a great pervasive effect, survey/study were conducted to plan the construction of facilities for natural gas vehicle fuel supply in future. In the survey, the paper summed up the state of CEV spread in the Hyogo prefecture, the state of construction of fuel supply facilities, etc. Further, by the questionnaire survey, the needs for construction of fuel supply facilities were grasped, and the intention of introducing natural gas vehicle was sounded out. In the study of a wide-area construction plan for natural gas fuel supply facilities, the Hanshin/Harima region was divided into zones based on geographical conditions, traffic system, etc., and the number of the needed fuel supply facilities was calculated which corresponds to the targeted number of natural gas vehicle introduction set up by the nation. Moreover, by the questionnaire survey, the needs for fuel supply facilities were grasped, and a method for setting up the order of priority in the construction was determined/proposed. Through the study of these, a manual was made out which is usable for the CEV introduction and the construction plan for natural gas fuel supply facilities in other regions. (NEDO)

  8. A review of chemical decontamination systems for nuclear facilities

    International Nuclear Information System (INIS)

    Chen, L.; Chamberlain, D.B.; Conner, C.; Vandegrift, G.F.

    1996-01-01

    With the downsizing of the Department of Energy (DOE) complex, many of its buildings and facilities will be decommissioned and dismantled. As part of this decommissioning, some form of decontamination will be required. To develop an appropriate technology for in situ chemical decontamination of equipment interiors in the decommissioning of DOE nuclear facilities, knowledge of the existing chemical decontamination methods is needed. This paper attempts to give an up-to-date review of chemical decontamination methods. This survey revealed that aqueous systems are the most widely used for the decontamination and cleaning of metal surfaces. We have subdivided the aqueous systems by types of chemical solvent: acid, alkaline permanganate, highly oxidizing, peroxide, and proprietary. Two other systems, electropolishing and foams and gels, are also described in this paper

  9. Quality of the delivery services in health facilities in Northern Ethiopia.

    Science.gov (United States)

    Fisseha, Girmatsion; Berhane, Yemane; Worku, Alemayehu; Terefe, Wondwossen

    2017-03-09

    Substantial improvements have been observed in the coverage of and access to maternal health service, especially in skilled birth attendants, in Ethiopia. However, the quality of care has been lagging behind. Therefore, this study investigated the status of the quality of delivery services in Northern Ethiopia. A facility based survey was conducted from December 2014 to February 2015 in Northern Ethiopia. The quality of delivery service was assessed in 32 health facilities using a facility audit checklist, by reviewing delivery, by conducting in-depth interview and observation, and by conducting exit interviews with eligible mothers. Facilities were considered as 'good quality' if they scored positively on 75% of the quality indicators set in the national guidelines for all the three components; input (materials, infrastructure, and human resource), process (adherence to standard care procedures during intrapartum and immediate postpartum periods) and output (the mothers' satisfaction and utilization of lifesaving procedures). Overall 2 of 32 (6.3%) of the study facilities fulfilled all the three quality components; input, process and output. Two of the three components were assessed as good in 11 of the 32 (34.4%) health facilities. The input quality was the better of the other quality components; which was good in 21 out of the 32 (65.6%) health facilities. The process and output quality was good in only 10 of the 32 (31.3%) facilities. Only 6.3% of the studied health facilities had good quality in all three dimensions of quality measures that was done in accordance to the national delivery service guidelines. The most compromised quality component was the process. Systematic and sustained efforts need to be strengthened to improve all dimensions of quality in order to achieve the desired quality of delivery services and increase the proportion of births occurring in health facilities.

  10. Formerly utilized MED/AEC sites remedial action program. Radiological survey of the former Horizons, Inc., metal handling facility, Cleveland, Ohio. Final report

    International Nuclear Information System (INIS)

    Leggett, R.W.; Cottrell, W.D.; Shinpaugh, W.H.; Doane, R.W.; Haywood, F.F.; Johnson, W.M.

    1979-02-01

    The results of a radiological survey of the former Horizons, Inc., metal handling facility in Cleveland, Ohio, are presented in this report. During the 1940's and early 1950's, two of the three buildings on this site (Buildings B and C) were used for the production of granular thorium metal. The survey included measurements related to the following: fixed and transferable alpha and beta-gamma contamination levels on the surfaces in Buildings B and C and on the roofs of these buildings; external gamma radiation levels at 1 m above the floors and grounds on and near the property; radionuclide concentrations in soil, water, and other materials collected from surfaces and drains inside Buildings B and C, from beneath the floor in Building C, and from outdoor locations on and near the site; and thoron ( 220 Rn) daughter concentrations in the air in Buildings B and C. Elevated concentrations of 232 Th, 228 Ra, 228 Th, and 230 Th were found in some samples. Alpha and beta-gamma contamination levels exceeded applicable guideline limits in some areas of Buildings B and C. External gamma radiation levels, approximately 10 times the average background level, were measured at isolated points in and near Building B. Thorium B ( 212 Pb) concentrations in air in Building B were near the Radioactivity Concentration Guide (RCG) level. Most of the elevated radiation levels were found indoors in areas presently used for storage. Outdoors on and near the site, significant radiation levels were found only near the east wall of Building B

  11. Gaps in the implementation of antenatal syphilis detection and treatment in health facilities across sub-Saharan Africa.

    Science.gov (United States)

    Kanyangarara, Mufaro; Walker, Neff; Boerma, Ties

    2018-01-01

    Syphilis in pregnancy is an under-recognized public health problem, especially in sub-Saharan Africa which accounts for over 60% of the global burden of syphilis. If left untreated, more than half of maternal syphilis cases will result in adverse pregnancy outcomes including stillbirth and fetal loss, neonatal death, prematurity or low birth weight, and neonatal infections. Achieving universal coverage of antenatal syphilis screening and treatment has been the focus of the global campaign for the elimination of mother-to-child transmission of syphilis. However, little is known about the availability of antenatal syphilis screening and treatment across sub-Saharan Africa. The objective of this study was to estimate the 'likelihood of appropriate care' for antenatal syphilis screening and treatment by analyzing health facility surveys and household surveys conducted from 2010 to 2015 in 12 sub-Saharan African countries. In this secondary data analysis, we linked indicators of health facility readiness to provide antenatal syphilis detection and treatment from Service Provision Assessments (SPAs) and Service Availability and Readiness Assessments (SARAs) to indicators of ANC use from the Demographic and Health Surveys (DHS) to compute estimates of the 'likelihood of appropriate care'. Based on data from 5,593 health facilities that reported offering antenatal care (ANC) services, the availability of syphilis detection and treatment in ANC facilities ranged from 2% to 83%. The availability of syphilis detection and treatment was substantially lower in ANC facilities in West Africa compared to the other sub-regions. Levels of ANC attendance were high (median 94.9%), but only 27% of ANC attendees initiated care at less than 4 months gestation. We estimated that about one in twelve pregnant women received ANC early (<4 months) at a facility ready to provide syphilis detection and treatment (median 8%, range 7-32%). The largest implementation bottleneck identified was low

  12. Classification of High-Rise Residential Building Facilities: A Descriptive Survey on 170 Housing Scheme in Klang Valley

    OpenAIRE

    Abd Wahab Siti Rashidah Hanum; Che Ani Adi Irfan; Sairi Ahmad; Mohd Tawil Norngainy; Abd Razak Mohd Zulhanif

    2016-01-01

    High-rise residential building is a type of housing that has multi-dwelling units built on the same land. This type of housing has become popular each year in urban area due to the increasing cost of land. There are several common facilities provided in high-rise residential building. For example playground, swimming pool, gymnasium, 24 hours security system such as CCTV, access card and so on. Thus, maintenance works of the common facilities must be well organised. The purpose of this paper ...

  13. Can contracted out health facilities improve access, equity, and quality of maternal and newborn health services? Evidence from Pakistan.

    Science.gov (United States)

    Zaidi, Shehla; Riaz, Atif; Rabbani, Fauziah; Azam, Syed Iqbal; Imran, Syeda Nida; Pradhan, Nouhseen Akber; Khan, Gul Nawaz

    2015-11-25

    The case of contracting out government health services to non-governmental organizations (NGOs) has been weak for maternal, newborn, and child health (MNCH) services, with documented gains being mainly in curative services. We present an in-depth assessment of the comparative advantages of contracting out on MNCH access, quality, and equity, using a case study from Pakistan. An end-line, cross-sectional assessment was conducted of government facilities contracted out to a large national NGO and government-managed centres serving as controls, in two remote rural districts of Pakistan. Contracting out was specific for augmenting MNCH services but without contractual performance incentives. A household survey, a health facility survey, and focus group discussions with client and spouses were used for assessment. Contracted out facilities had a significantly higher utilization as compared to control facilities for antenatal care, delivery, postnatal care, emergency obstetric care, and neonatal illness. Contracted facilities had comparatively better quality of MNCH services but not in all aspects. Better household practices were also seen in the district where contracting involved administrative control over outreach programs. Contracting was also faced with certain drawbacks. Facility utilization was inequitably higher amongst more educated and affluent clients. Contracted out catchments had higher out-of-pocket expenses on MNCH services, driven by steeper transport costs and user charges for additional diagnostics. Contracting out did not influence higher MNCH service coverage rates across the catchment. Physical distances, inadequate transport, and low demand for facility-based care in non-emergency settings were key client-reported barriers. Contracting out MNCH services at government health facilities can improve facility utilization and bring some improvement in  quality of services. However, contracting out of health facilities is insufficient to increase

  14. Summary, the 20th quality control survey for radioisotopes in vitro tests in Japan, 1998

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-11-01

    For advancement of radioisotope in vitro tests such as radioimmunoassay and immunoradiometric assay, the Subcommittee for Radioisotope in vitro Test in Medical and Pharmaceutical Committee of Japan Radioisotope Association has conducted the yearly quality control survey for the test facilities in Japan since 1978. This is the summary of the 20th survey in 1998 where non-radioisotope tests like enzyme-immunoassay were involved as well. The survey was done for 143 facilities: 20 national and public university hospitals, 18 private university hospitals, 8 national hospitals, 13 public hospitals, 21 private hospitals, 41 hygienic laboratories and 22 manufacturers of reagents. Facilities examined intra- and between day-reproducibility, freeze-thaw effect and time change of the measured values on the same samples. Assays were for: growth hormone (h), somatomedin C, follicle stimulating h, luteinizing h, prolactin, thyroid stimulating h, triiodothyronines, thyroxines, thyroxine binding protein, calcitonin, insulin, C-peptide, glucagons, gastrin, testosterones, estradiol, progesterone, gonadotropin, 17{alpha}-hydroxyprogesterone, aldosterone, cortisol, dehydroepiandorosterone sulfate, renin, IgE, digoxin, {alpha}-fetoprotein, carcinoembryonic antigen, tissue polypeptide antigen, CA (125, 19-9 and 15-3), prostatic acid phosphatase, prostate specific antigen, {beta}2-microglobulin, ferritin, and neuron specific enolase. There was no great difference between this and last survey results although tendency of improvement was recognized. There were problems to be solved from the standpoint of clinical practice. (K.H.)

  15. Assessment of national systems for obtaining local siting acceptance of nuclear waste management facilities (October 1, 1985). Volume I. Political structure and formal system for obtaining approvals for siting waste management facilities

    International Nuclear Information System (INIS)

    Paige, H.W.; Numark, N.J.

    1985-01-01

    This report is the fourth in a series of periodic surveys of approaches and progress in other countries in dealing with the problems of obtaining local acceptance for siting of waste management facilities. This volume contains the following sections: Nation's political/industrial structure for obtaining waste management siting decisions; and Nation's formal legal procedure for obtaining necessary approvals for siting nuclear waste management facilities. Two of the countries visited, Finland and Sweden, have had major changes in the past two years in their formal/legal procedures for obtaining waste management siting decisions. (LM)

  16. Current experiences and educational preferences of general practitioners and staff caring for people with dementia living in residential facilities.

    Science.gov (United States)

    Beer, Christopher; Horner, Barbara; Almeida, Osvaldo P; Scherer, Samuel; Lautenschlager, Nicola T; Bretland, Nick; Flett, Penelope; Schaper, Frank; Flicker, Leon

    2009-08-12

    Residential care is important for older adults, particularly for those with advanced dementia and their families. Education interventions that achieve sustainable improvement in the care of older adults are critical to quality care. There are few systematic data available regarding the educational needs of Residential Care Facility (RCF) staff and General Practitioners (GPs) relating to dementia, or the sustainability of educational interventions. We sought to determine participation in dementia education, perceived levels of current knowledge regarding dementia, perceived unmet educational needs, current barriers, facilitators and preferences for dementia education. A mixed methods study design was utilised. A survey was distributed to a convenience sample of general practitioners, and staff in 223 consecutive residential care facilities in Perth, Western Australia. Responses were received from 102 RCF staff working in 10 facilities (out of 33 facilities who agreed to distribute the survey) and 202 GPs (19% of metropolitan GPs). Quantitative survey data were summarised descriptively and chi squared statistics were used to analyse the distribution of categorical variables. Qualitative data were collected from general practitioners, staff in residential care facilities and family carers of people with dementia utilizing individual interviews, surveys and focus groups. Qualitative data were analysed thematically. Among RCF staff and GPs attending RCF, participation in dementia education was high, and knowledge levels generally perceived as good. The individual experiences and needs of people with dementia and their families were emphasised. Participants identified the need for a person centred philosophy to underpin educational interventions. Limited time was a frequently mentioned barrier, especially in relation to attending dementia care education. Perceived educational needs relating to behaviours of concern, communication, knowledge regarding dementia, aspects of

  17. Current experiences and educational preferences of general practitioners and staff caring for people with dementia living in residential facilities

    Directory of Open Access Journals (Sweden)

    Scherer Samuel

    2009-08-01

    Full Text Available Abstract Background Residential care is important for older adults, particularly for those with advanced dementia and their families. Education interventions that achieve sustainable improvement in the care of older adults are critical to quality care. There are few systematic data available regarding the educational needs of Residential Care Facility (RCF staff and General Practitioners (GPs relating to dementia, or the sustainability of educational interventions. We sought to determine participation in dementia education, perceived levels of current knowledge regarding dementia, perceived unmet educational needs, current barriers, facilitators and preferences for dementia education. Methods A mixed methods study design was utilised. A survey was distributed to a convenience sample of general practitioners, and staff in 223 consecutive residential care facilities in Perth, Western Australia. Responses were received from 102 RCF staff working in 10 facilities (out of 33 facilities who agreed to distribute the survey and 202 GPs (19% of metropolitan GPs. Quantitative survey data were summarised descriptively and chi squared statistics were used to analyse the distribution of categorical variables. Qualitative data were collected from general practitioners, staff in residential care facilities and family carers of people with dementia utilizing individual interviews, surveys and focus groups. Qualitative data were analysed thematically. Results Among RCF staff and GPs attending RCF, participation in dementia education was high, and knowledge levels generally perceived as good. The individual experiences and needs of people with dementia and their families were emphasised. Participants identified the need for a person centred philosophy to underpin educational interventions. Limited time was a frequently mentioned barrier, especially in relation to attending dementia care education. Perceived educational needs relating to behaviours of concern

  18. Radiological Characterization and Final Facility Status Report Tritium Research Laboratory

    International Nuclear Information System (INIS)

    Garcia, T.B.; Gorman, T.P.

    1996-08-01

    This document contains the specific radiological characterization information on Building 968, the Tritium Research Laboratory (TRL) Complex and Facility. We performed the characterization as outlined in its Radiological Characterization Plan. The Radiological Characterization and Final Facility Status Report (RC ampersand FFSR) provides historic background information on each laboratory within the TRL complex as related to its original and present radiological condition. Along with the work outlined in the Radiological Characterization Plan (RCP), we performed a Radiological Soils Characterization, Radiological and Chemical Characterization of the Waste Water Hold-up System including all drains, and a Radiological Characterization of the Building 968 roof ventilation system. These characterizations will provide the basis for the Sandia National Laboratory, California (SNL/CA) Site Termination Survey .Plan, when appropriate

  19. The role of marketing research in securing a certificate of need for a new renal transplant facility.

    Science.gov (United States)

    Tucker, L R; Laric, M V; McCann, D

    1991-06-01

    The authors describe how a negative Certificate of Need decision on the establishment of a new renal transplantation center was reversed by the reintroduction of arguments based on primary data. Specifically, a research project was undertaken to survey attitudes of past and potential patients toward using the new facility. In addition to overturning the negative decision, the data gathered were of significant value to hospital and transplantation facility administrators.

  20. Facility effluent monitoring plan determinations for the 200 Area facilities

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1991-11-01

    The following facility effluent monitoring plan determinations document the evaluations conducted for the Westinghouse Hanford Company 200 Area facilities (chemical processing, waste management, 222-S Laboratory, and laundry) on the Hanford Site in south central Washington State. These evaluations determined the need for facility effluent monitoring plans for the 200 Area facilities. The facility effluent monitoring plan determinations have been prepared in accordance with A Guide for Preparing Hanford Site Facility Effluent Monitoring Plans, WHC-EP-0438 (WHC 1991). The Plutonium/Uranium Extraction Plant and UO 3 facility effluent monitoring plan determinations were prepared by Los Alamos Technical Associates, Richland, Washington. The Plutonium Finishing Plant, Transuranic Waste Storage and Assay Facility, T Plant, Tank Farms, Low Level Burial Grounds, and 222-S Laboratory determinations were prepared by Science Applications International Corporation of Richland, Washington. The B Plant Facility Effluent Monitoring Plan Determination was prepared by ERCE Environmental Services of Richland, Washington

  1. System reliability as perceived by maintenance personnel on petroleum production facilities

    International Nuclear Information System (INIS)

    Antonovsky, A.; Pollock, C.; Straker, L.

    2016-01-01

    The aim of this research was to understand the relationship between maintenance staff perceptions of organisational effectiveness and operational reliability in petroleum operations. Engineering measures exist that assess the effectiveness of maintenance and reliability of equipment. These measures are typically retrospective and may not provide insight into what impedes system reliability. Perceptions of organisational effectiveness by the workforce may provide a predictive measure that could improve our understanding of the human factors that influence system reliability. Maintenance personnel (n=133) from nine petroleum production facilities completed a survey as part of a study of human factors and maintenance reliability. 69 respondents (51.9%) provided comments to an open-ended question in the survey, and these data were analysed using Interpretive Phenomenological Analysis to extract themes. Four super-ordinate themes were identified from the analysis: 1) Communication and access to information, 2) Efficiency of current work systems, 3) Need for better workgroup support, and 4) Management impacts on the workplace. We found a significant relationship between the frequency of the four super-ordinate themes and the facility reliability level as measured by ‘Mean Time Between Failures’: χ"2(6,N=158)=16.2, p=.013. These results demonstrated that operational effectiveness might be differentiated on the basis of survey-derived perceptions of maintenance personnel. - Highlights: • Thematic analysis of survey comments provided insights into workplace reliability • Worker’s comments on reliability related to technical data on time between failures • Management decision-making was the main theme in the lower reliability workplaces • Improving efficiency was the main theme in the higher reliability workplaces • Communication and better workgroup support were themes at all reliability levels

  2. Three dimensional investigation of oceanic active faults. A demonstration survey

    Energy Technology Data Exchange (ETDEWEB)

    Nakao, Seizo; Kishimoto, Kiyoyuki; Kuramoto, Shinichi; Sato, Mikio [Geological Survey of Japan, Tsukuba, Ibaraki (Japan)

    1998-02-01

    In order to upgrade probability of activity and action potential evaluation of oceanic active faults which have some important effects on nuclear facilities, trench type oceanic active fault was investigated three dimensionally. Contents of the investigation were high precision sea bottom topographic survey and sea bottom back scattering wave image data observation by using a sea bottom topography acoustic imaginator. And, by high resolution earthquake wave survey, high precision survey of an active fault under sea bottom was conducted to detect oceanic active faults three-dimensionally. Furthermore, the generally issued data were summarized to promote to construct a data base for evaluating the active faults. (G.K.)

  3. Three dimensional investigation of oceanic active faults. A demonstration survey

    International Nuclear Information System (INIS)

    Nakao, Seizo; Kishimoto, Kiyoyuki; Kuramoto, Shinichi; Sato, Mikio

    1998-01-01

    In order to upgrade probability of activity and action potential evaluation of oceanic active faults which have some important effects on nuclear facilities, trench type oceanic active fault was investigated three dimensionally. Contents of the investigation were high precision sea bottom topographic survey and sea bottom back scattering wave image data observation by using a sea bottom topography acoustic imaginator. And, by high resolution earthquake wave survey, high precision survey of an active fault under sea bottom was conducted to detect oceanic active faults three-dimensionally. Furthermore, the generally issued data were summarized to promote to construct a data base for evaluating the active faults. (G.K.)

  4. Facilities & Leadership

    Data.gov (United States)

    Department of Veterans Affairs — The facilities web service provides VA facility information. The VA facilities locator is a feature that is available across the enterprise, on any webpage, for the...

  5. Facility model for the Los Alamos Plutonium Facility

    International Nuclear Information System (INIS)

    Coulter, C.A.; Thomas, K.E.; Sohn, C.L.; Yarbro, T.F.; Hench, K.W.

    1986-01-01

    The Los Alamos Plutonium Facility contains more than sixty unit processes and handles a large variety of nuclear materials, including many forms of plutonium-bearing scrap. The management of the Plutonium Facility is supporting the development of a computer model of the facility as a means of effectively integrating the large amount of information required for material control, process planning, and facility development. The model is designed to provide a flexible, easily maintainable facility description that allows the faciltiy to be represented at any desired level of detail within a single modeling framework, and to do this using a model program and data files that can be read and understood by a technically qualified person without modeling experience. These characteristics were achieved by structuring the model so that all facility data is contained in data files, formulating the model in a simulation language that provides a flexible set of data structures and permits a near-English-language syntax, and using a description for unit processes that can represent either a true unit process or a major subsection of the facility. Use of the model is illustrated by applying it to two configurations of a fictitious nuclear material processing line

  6. Radiological Survey Results for Areas A1 North, A5A, A6, and B2 at the Molycorp Washington Remediation Project, Washington, Pennsylvania

    International Nuclear Information System (INIS)

    W.C. Adams

    2007-01-01

    Perform radiological surveys of the Molycorp Washington Remediation Project (MWRP) facility in Washington, Pennsylvania. The U.S. Nuclear Regulatory Commission (NRC) requested the Oak Ridge Institute for Science and Education (ORISE) to provide limited training pertaining to ORISE radiological soil scanning and sampling procedures to the Pennsylvania Department of Environmental Protection (PADEP) personnel. In addition, the NRC also requested that ORISE perform radiological surveys of the Molycorp Washington Remediation Project (MWRP) facility in Washington, Pennsylvania (Figure 1). ORISE has and will continue to interface with PADEP personnel in a joint effort to perform confirmatory radiological surveys, consisting of gamma scans and soil sampling, at the MWRP facility. PADEP personnel will continue to submit soil samples that they collect to ORISE for analyses. PADEP sample results, along with ORISE results, will be provided to the NRC and PADEP so that decisions regarding the radiological status of the surveyed areas can be determined. ORISE performed radiological surveys during the period of November 28 and 29, 2006. The survey unit (SU) available for ORISE radiological survey activities was Area A1 North. The MWRP final status survey (FSS) results for Area A1 North were reviewed prior to these survey activities. Prior to ORISE's survey activities, PADEP personnel had performed radiological surveys and collected soil samples from SU Areas A5A and A6. These samples were provided to ORISE for analyses while on site. After the ORISE radiological surveys, PADEP personnel collected soil samples from SU Areas A2 and B2 and these samples were shipped to ORISE for analyses in January 2007. Figure 2 depicts the MWRP Areas A through D; ORISE and PADEP personnel performed survey activities in portions of Areas A and B. For interlaboratory comparison analyses with MWRP's site contractor, Malcolm Pirnie (MP), ORISE requested soil samples from the Area A1 soil stockpiles

  7. Survey on the Sources of Information in Science, Technology and Commerce in the State of Penang, Malaysia

    Science.gov (United States)

    Tee, Lim Huck; Fong, Tang Wan

    1973-01-01

    Penang, Malaysia is undergoing rapid industrialization to stimulate its economy. A survey was conducted to determine what technical, scientific, and commercial information sources were available. Areas covered in the survey were library facilities, journals, commercial reference works and audio-visual materials. (DH)

  8. Supply-side barriers to maternity-care in India: a facility-based analysis.

    Directory of Open Access Journals (Sweden)

    Santosh Kumar

    Full Text Available BACKGROUND: Health facilities in many low- and middle-income countries face several types of barriers in delivering quality health services. Availability of resources at the facility may significantly affect the volume and quality of services provided. This study investigates the effect of supply-side determinants of maternity-care provision in India. METHODS: Health facility data from the District-Level Household Survey collected in 2007-2008 were analyzed to explore the effects of supply-side factors on the volume of delivery care provided at Indian health facilities. A negative binomial regression model was applied to the data due to the count and over-dispersion property of the outcome variable (number of deliveries performed at the facility. RESULTS: Availability of a labor room (Incidence Rate Ratio [IRR]: 1.81; 95% Confidence Interval [CI]: 1.68-1.95 and facility opening hours (IRR: 1.43; CI: 1.35-1.51 were the most significant predictors of the volume of delivery care at the health facilities. Medical and paramedical staff were found to be positively associated with institutional deliveries. The volume of deliveries was also higher if adequate beds, essential obstetric drugs, medical equipment, electricity, and communication infrastructures were available at the facility. Findings were robust to the inclusion of facility's catchment area population and district-level education, health insurance coverage, religion, wealth, and fertility. Separate analyses were performed for facilities with and without a labor room and results were qualitatively similar across these two types of facilities. CONCLUSIONS: Our study highlights the importance of supply-side barriers to maternity-care India. To meet Millennium Development Goals 4 and 5, policymakers should make additional investments in improving the availability of medical drugs and equipment at primary health centers (PHCs in India.

  9. Factors associated with health facility childbirth in districts of Kenya, Tanzania and Zambia

    DEFF Research Database (Denmark)

    Phiri, Selia Ng'anjo; Kiserud, Torvid; Kvåle, Gunnar

    2014-01-01

    of delivery. Socioeconomic position was measured by employing a construct of educational attainment and wealth index. All analyses were stratified by district and urban-rural residence. RESULTS: There were substantial inter-district differences in proportion of health facility childbirth. Facility childbirth......BACKGROUND: Maternal mortality continues to be a heavy burden in low and middle income countries where half of all deliveries take place in homes without skilled attendance. The study aimed to investigate the underlying and proximate determinants of health facility childbirth in rural and urban...... areas of three districts in Kenya, Tanzania and Zambia. METHODS: A population-based survey was conducted in 2007 as part of the 'REsponse to ACcountable priority setting for Trust in health systems' (REACT) project. Stratified random cluster sampling was used and the data included information on place...

  10. Survey Analysis on Nuclear Security Culture Recognition of Nuclear Facility in 2014

    International Nuclear Information System (INIS)

    Hong, Yunjeong; Lee, Jeongho; Kim, Jaekwang

    2015-01-01

    All organizations involved in implementing physical protection should give due priority to the security culture, to its development and maintenance necessary to ensure its effective implementation in the entire organization. In this context, Korea Institute of Non-proliferation and Control(KINAC) confirms recognition about protection of people who work in nuclear field and developed questionnaire for utilizing fundamental data for nuclear security culture enhancement activity and conducted a survey. As a result, systematic education needs to employees. Choosing differentiated topic is required to consider employees because recognition level of age, position and division is different. And a variety of education technology as obligatory education such as filling the course time or the one-off thing has limitation. And taking complementary measures needs since there were many opinions that employees feel difficult to understand papers such as regulation and guidelines and so on related security. Finally, we hope to make fundament available to evaluate nuclear security culture recognition level based on the existing questionnaire would be changed to realistic and enhancement in recognition survey for future nuclear security culture

  11. Survey Analysis on Nuclear Security Culture Recognition of Nuclear Facility in 2014

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Yunjeong; Lee, Jeongho; Kim, Jaekwang [Korea Institute of Nonproliferation and Control International Nuclear Security Academy, Daejeon (Korea, Republic of)

    2015-05-15

    All organizations involved in implementing physical protection should give due priority to the security culture, to its development and maintenance necessary to ensure its effective implementation in the entire organization. In this context, Korea Institute of Non-proliferation and Control(KINAC) confirms recognition about protection of people who work in nuclear field and developed questionnaire for utilizing fundamental data for nuclear security culture enhancement activity and conducted a survey. As a result, systematic education needs to employees. Choosing differentiated topic is required to consider employees because recognition level of age, position and division is different. And a variety of education technology as obligatory education such as filling the course time or the one-off thing has limitation. And taking complementary measures needs since there were many opinions that employees feel difficult to understand papers such as regulation and guidelines and so on related security. Finally, we hope to make fundament available to evaluate nuclear security culture recognition level based on the existing questionnaire would be changed to realistic and enhancement in recognition survey for future nuclear security culture.

  12. Where There Is No Toilet: Water and Sanitation Environments of Domestic and Facility Births in Tanzania

    Science.gov (United States)

    Benova, Lenka; Cumming, Oliver; Gordon, Bruce A.; Magoma, Moke; Campbell, Oona M. R.

    2014-01-01

    Background Inadequate water and sanitation during childbirth are likely to lead to poor maternal and newborn outcomes. This paper uses existing data sources to assess the water and sanitation (WATSAN) environment surrounding births in Tanzania in order to interrogate whether such estimates could be useful for guiding research, policy and monitoring initiatives. Methods We used the most recent Tanzania Demographic and Health Survey (DHS) to characterise the delivery location of births occurring between 2005 and 2010. Births occurring in domestic environments were characterised as WATSAN-safe if the home fulfilled international definitions of improved water and improved sanitation access. We used the 2006 Service Provision Assessment survey to characterise the WATSAN environment of facilities that conduct deliveries. We combined estimates from both surveys to describe the proportion of all births occurring in WATSAN-safe environments and conducted an equity analysis based on DHS wealth quintiles and eight geographic zones. Results 42.9% (95% confidence interval: 41.6%–44.2%) of all births occurred in the woman's home. Among these, only 1.5% (95% confidence interval: 1.2%–2.0%) were estimated to have taken place in WATSAN-safe conditions. 74% of all health facilities conducted deliveries. Among these, only 44% of facilities overall and 24% of facility delivery rooms were WATSAN-safe. Combining the estimates, we showed that 30.5% of all births in Tanzania took place in a WATSAN-safe environment (range of uncertainty 25%–42%). Large wealth-based inequalities existed in the proportion of births occurring in domestic environments based on wealth quintile and geographical zone. Conclusion Existing data sources can be useful in national monitoring and prioritisation of interventions to improve poor WATSAN environments during childbirth. However, a better conceptual understanding of potentially harmful exposures and better data are needed in order to devise and apply

  13. CATHARE 2 analysis of the small break LOCA experiment SP-SB-03, conducted in SPES facility

    International Nuclear Information System (INIS)

    Meloni, P.

    1995-01-01

    SPES integral test facility is a scale model of a commercial three-loop PWR plant, making the simulation of a wide range of accident scenarios possible. A Small Break Loss of Coolant test was carried out in this facility in 1991 to serve as a counterpart of tests conducted on BETHSY (France), LSTF (Japan) and LOBI (EC) facilities. A post-test analysis of this test, performed with CATHARE 2 code was realized by ENEA in the framework of the co-operation ENEA-CEA on advanced reactors. This paper presents a survey of the results of the post-test calculation. (author). 5 refs, 11 figs, 3 tabs

  14. Laboratory facilities increased by gifts

    International Nuclear Information System (INIS)

    1968-01-01

    As a result of gifts from two Member States facilities at the Agency's research centre at Seibersdorf, Austria, have been increased. New equipment has been provided by France and Romania. The French equipment is a coincidence counter to be operated in conjunction with a computer and is valued at $35 000. It can give automatically an exact measurement of radioactivity in a chemical solution containing radioisotopes. This means that a sample of the solution can be sent to another laboratory to be used for calibrating instruments and checking results of research work. Since 1963 nearly 8 000 radioactive solutions to be used as standards have been sent from Seibersdorf to research laboratories and hospitals in 56 countries. The demand continues to grow, and in order to meet it the equipment was developed by the Saclay Research Centre of the Commissariat a l'Energie Atomique in collaboration with Seibersdorf. From Romania have come six electronic measuring instruments worth $6 000 to assist nuclear research, surveying and prospecting. Three are electronic scalers for experimental work involving the counting of radioactive emissions, and three are survey meters for detecting the presence of radioactivity in geological samples. (author)

  15. The regulatory role of the Hungarian Geological Survey in the closure of Mecsek uranium mine

    International Nuclear Information System (INIS)

    Hamor, T.; Gombor, L.

    2001-01-01

    Under Mining Act XLIII established in 1993, the Hungarian Geological Survey was given a wide range of authority related to the environment, mining, nuclear and general constructions. In implementing these task the Survey will be supported by the well established Geological Institute of Hungary and the Eoetvoes Lorand Geophysical Institute. The Survey's role in the nuclear field includes the licensing of plans and reports on geologically related research to any nuclear facilities. The Hungarian Geological Survey is also co-authority on matters related to the establishment, construction, modification and closure, environmental protection of nuclear facilities in general and all matter related to uranium mining. The Survey's regulatory activity in radioactive waste management follows the Decree of the Minister of Industry and Tourism 62/1997 which is based on the Atomic Energy Act CXVI of 1966. These regulations were prepared in harmony with the OECD Nuclear Energy Agency and the International Atomic Energy Agency conventions, standards and guides and those of other countries. Case histories on the applications of these regulations to the closure of Mecsek uranium mine and the operation of the research laboratory tunnel for long-lived, high level radioactive waste are presented here. (author)

  16. Cost calculations for decommissioning and dismantling of nuclear research facilities

    International Nuclear Information System (INIS)

    Andersson, I.; Backe, S.; Cato, A.; Lindskog, S.; Efraimsson, H.; Iversen, Klaus; Salmenhaara, S.; Sjoeblom, R.

    2008-07-01

    Today, it is recommended that planning of decommission should form an integral part of the activities over the life cycle of a nuclear facility (planning, building and operation), but it was only in the nineteen seventies that the waste issue really surface. Actually, the IAEA guidelines on decommissioning have been issued as recently as over the last ten years, and international advice on finance of decommissioning is even younger. No general international guideline on cost calculations exists at present. This implies that cost calculations cannot be performed with any accuracy or credibility without a relatively detailed consideration of the radiological prerequisites. Consequently, any cost estimates based mainly on the particulars of the building structures and installations are likely to be gross underestimations. The present study has come about on initiative by the Swedish Nuclear Power Inspectorate (SKI) and is based on a common need in Denmark, Finland, Norway and Sweden. The content of the report may be briefly summarised as follows. The background covers design and operation prerequisites as well as an overview of the various nuclear research facilities in the four participating countries: Denmark, Finland, Norway and Sweden. The purpose of the work has been to identify, compile and exchange information on facilities and on methodologies for cost calculation with the aim of achieving an 80 % level of confidence. The scope has been as follows: 1) to establish a Nordic network 2) to compile dedicated guidance documents on radiological surveying, technical planning and financial risk identification and assessment 3) to compile and describe techniques for precise cost calculations at early stages 4) to compile plant and other relevant data A separate section is devoted in the report to good practice for the specific purpose of early but precise cost calculations for research facilities, and a separate section is devoted to techniques for assessment of cost

  17. Cost calculations for decommissioning and dismantling of nuclear research facilities

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I. (Studsvik Nuclear AB (Sweden)); Backe, S. (Institute for Energy Technology (Norway)); Cato, A.; Lindskog, S. (Swedish Nuclear Power Inspectorate (Sweden)); Efraimsson, H. (Swedish Radiation Protection Authority (Sweden)); Iversen, Klaus (Danish Decommissioning (Denmark)); Salmenhaara, S. (VTT Technical Research Centre of Finland (Finland)); Sjoeblom, R. (Tekedo AB, (Sweden))

    2008-07-15

    Today, it is recommended that planning of decommission should form an integral part of the activities over the life cycle of a nuclear facility (planning, building and operation), but it was only in the nineteen seventies that the waste issue really surface. Actually, the IAEA guidelines on decommissioning have been issued as recently as over the last ten years, and international advice on finance of decommissioning is even younger. No general international guideline on cost calculations exists at present. This implies that cost calculations cannot be performed with any accuracy or credibility without a relatively detailed consideration of the radiological prerequisites. Consequently, any cost estimates based mainly on the particulars of the building structures and installations are likely to be gross underestimations. The present study has come about on initiative by the Swedish Nuclear Power Inspectorate (SKI) and is based on a common need in Denmark, Finland, Norway and Sweden. The content of the report may be briefly summarised as follows. The background covers design and operation prerequisites as well as an overview of the various nuclear research facilities in the four participating countries: Denmark, Finland, Norway and Sweden. The purpose of the work has been to identify, compile and exchange information on facilities and on methodologies for cost calculation with the aim of achieving an 80 % level of confidence. The scope has been as follows: 1) to establish a Nordic network 2) to compile dedicated guidance documents on radiological surveying, technical planning and financial risk identification and assessment 3) to compile and describe techniques for precise cost calculations at early stages 4) to compile plant and other relevant data A separate section is devoted in the report to good practice for the specific purpose of early but precise cost calculations for research facilities, and a separate section is devoted to techniques for assessment of cost

  18. Description of the U.S. Geological Survey's slug-tests at the Hallam Nuclear Facility, July to November 1994

    International Nuclear Information System (INIS)

    1995-01-01

    An aquifer test agreement between the US Department of Energy (USDOE) and the US Geological Survey (USGS) was set up to log and measure the aquifer response in two observation wells, IB and 4C at the Hallam Nuclear Facility, Hallam, Nebraska. Observation wells 1B and 4C are owned by the USDOE and were installed by HWS Technologies Inc. of Lincoln, Nebraska, in June 1993. These observation wells were measured monthly from September 1993 to August 1994 by using a graduated steel tape. The accuracy of these water-level measurements is approximately ±0.02 foot. Also well 1B contained a submersible pressure transducer to record hourly water-level data during this same period. During access of the wells, personnel wear clean disposable latex gloves, a hard hat, and safety glasses. Directly following each measurement the steel-tape was rinsed with deionized water and the effluent was disposed of in a 55-gallon drum. For the aquifer tests, observation wells 1B and 4C had submersible pressure transducers installed to monitor water-level responses. These pressure transducers were connected to an electronic data logger (edl) to record the water levels, atmospheric pressure from a barometric pressure gauge, and rainfall data from a tipping-bucket rain gauge. The data recorded on each edl was downloaded onto a field computer during each site visit, processed in the field, and then stored on the USGS's Data General workstations upon return to the District Office

  19. Surface Contamination Monitor and Survey Information Management System

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    Shonka Research Associates, Inc.`s (SRA) Surface Contamination Monitor and Survey Information management System (SCM/SIMS) is designed to perform alpha and beta radiation surveys of floors and surfaces and document the measured data. The SRA-SCM/SIMS technology can be applied to routine operational surveys, characterization surveys, and free release and site closure surveys. Any large nuclear site can make use of this technology. This report describes a demonstration of the SRA-SCM/SIMS technology. This demonstration is part of the chicago Pile-5 (CP-5) Large-Scale Demonstration Project (LSDP) sponsored by the US Department of Energy (DOE), Office of Science and Technology (ST), Deactivation and Decommissioning Focus Area (DDFA). The objective of the LSDP is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East`s (ANL) CP-5 Research Reactor Facility. The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies.

  20. Surface Contamination Monitor and Survey Information Management System

    International Nuclear Information System (INIS)

    1998-02-01

    Shonka Research Associates, Inc.'s (SRA) Surface Contamination Monitor and Survey Information management System (SCM/SIMS) is designed to perform alpha and beta radiation surveys of floors and surfaces and document the measured data. The SRA-SCM/SIMS technology can be applied to routine operational surveys, characterization surveys, and free release and site closure surveys. Any large nuclear site can make use of this technology. This report describes a demonstration of the SRA-SCM/SIMS technology. This demonstration is part of the chicago Pile-5 (CP-5) Large-Scale Demonstration Project (LSDP) sponsored by the US Department of Energy (DOE), Office of Science and Technology (ST), Deactivation and Decommissioning Focus Area (DDFA). The objective of the LSDP is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East's (ANL) CP-5 Research Reactor Facility. The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies