WorldWideScience

Sample records for surveillance test specimens

  1. Development of reconstitution method for surveillance specimens using surface activated joining

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Terumi; Kaihara, Shoichiro; Yoshida, Kazuo; Sato, Akira [Ishikawajima-Harima Heavy Industries Co. Ltd., Tokyo (Japan); Onizawa, Kunio; Nishiyama, Yutaka; Fukaya, Kiyoshi; Suzuki, Masahide

    1996-03-01

    Evaluation of embrittlement of reactor vessel steel due to irradiation requires surveillance tests. However, many surveillance specimens are necessary for nuclear plants life extension. Therefore, a specimen reconstitution technique has become important to provide the many specimens for continued surveillance. A surface activated joining (SAJ) method has been developed to join various materials together at low temperatures with little deformation, and is useful to bond irradiated specimens. To assess the validity of this method, Charpy impact tests were carried out, and the characteristics caused by heating during joining were measured. The test results showed the Charpy impact values were almost the same as base materials, and surface activated joining reduced heat affected zone to less than 2 mm. (author).

  2. Development of Reconstitution Technology for Surveillance Specimens

    International Nuclear Information System (INIS)

    Yasushi Atago; Shunichi Hatano; Eiichiro Otsuka

    2002-01-01

    The Japan Power Engineering and Inspection Corporation (JAPEIC) has been carrying out the project titled 'Nuclear Power Plant Integrated Management Technology (PLIM)' consigned by Japanese Ministry of Economy, Trade and Industry (METI) since 1996FY as a 10-years project. As one of the project themes, development of reconstitution technology for reactor pressure vessel (RPV/RV) surveillance specimens, which are installed in RPVs to monitor the neutron irradiation embrittlement on RPV/RV materials, is now on being carried out to deal with the long-term operation of nuclear power plants. The target of this theme is to establish the technical standard for applicability of reconstituted surveillance specimens including the reconstitution of the Charpy specimens and Compact Tension (CT) specimens. With the Charpy specimen reconstitution, application of 10 mm length inserts is used, which enables the conversion of tests from the LT-direction to the TL-direction. This paper presents the basic data from Charpy and CT specimens of RPV materials using the surveillance specimens obtained for un-irradiated materials including the following. 1) Reconstitution Technology of Charpy Specimens. a) The interaction between plastic zone and Heat Affected Zone (HAZ). b) The effects of the possible deviations from the standard specimens for the reconstituted specimens. 2) Reconstitution Technology of CT specimens. a) The correlation between fracture toughness and plastic zone width. Because the project is now in progress, this paper describes the outline of the results obtained as of the end of 2000 FY. (authors)

  3. On impact testing of subsize Charpy V-notch type specimens

    International Nuclear Information System (INIS)

    Mikhail, A.S.; Nanstad, R.K.

    1994-01-01

    The potential for using subsize specimens to determine the actual properties of reactor pressure vessel steels is receiving increasing attention for improved vessel condition monitoring that could be beneficial for light-water reactor plant-life extension. This potential is made conditional upon, on the one hand, by the possibility of cutting samples of small volume from the internal surface of the pressure vessel for determination of actual properties of the operating pressure vessel. The plant-life extension will require supplemental surveillance data that cannot be provided by the existing surveillance programs. Testing of subsize specimens manufactured from broken halves of previously tested surveillance Charpy V-notch (CVN) specimens offers an attractive means of extending existing surveillance programs. Using subsize CVN type specimens requires the establishment of a specimen geometry that is adequate to obtain a ductile-to-brittle transition curve similar to that obtained from full-size specimens. This requires the development of a correlation of transition temperature and upper-shelf toughness between subsize and full-size specimens. The present study was conducted under the Heavy-Section Steel Irradiation Program. Different published approaches to the use of subsize specimens were analyzed and five different geometries of subsize specimens were selected for testing and evaluation. The specimens were made from several types of pressure vessel steels with a wide range of yield strengths, transition temperatures, and upper-shelf energies (USEs). Effects of specimen dimensions, including depth, angle, and radius of notch have been studied. The correlation of transition temperature determined from different types of subsize specimens and the full-size specimen is presented. A new procedure for transforming data from subsize specimens was developed and is presented

  4. Development of the plant life management technology for RPV steels [ - Current status of surveillance test specimen reconstitution program -

    International Nuclear Information System (INIS)

    Kazunobu, Sakamoto; Eliichiro, Otsuka; Yoshiaki, Oka; Kosei, Taguchi; Michiyoshi, Yamamoto

    2001-01-01

    In order to develop the reconstitution technology to standardize surveillance test specimen reconstitution practices to deal with the extended service life of reactor pressure vessels, the Japan Power Engineering and Inspection Corporation (JAPEIC) has been carried out the project entrusted by the Ministry of International Trade and Industry (MITI). We focus on a correlation between the reduction of absorbed energy and the interaction of the heat affected zone (HAZ) and the plastic zone, to establish applicable reconstitution conditions for Charpy specimens. The relationship between the plastic zone width and the absorbed energy has been obtained by estimating the plastic zone width from the hardness distribution of the Charpy specimens. Impact tests of reconstituted specimens with 10 mm-length insert using the surface activated joining method were performed and the test results were compared to those obtained by the standard specimens. By comparing the length of insert material to the sum of HAZ width and plastic zone width, it is clear that the interaction causes the reduction of the absorbed energy. Hence, the applicable conditions of reconstituted Charpy specimens could be assessed by comparing the insert length to the sum of HAZ width and plastic zone width. Moreover the effects of the possible deviations from the standard shape and size specimens for the reconstituted specimens were studied. (authors)

  5. Structural analysis of 177-FA redesigned surveillance specimen holder tube

    International Nuclear Information System (INIS)

    Pryor, C.W.; Thoren, D.E.; Vames, G.J.; Harris, R.J.

    1976-08-01

    Because of in-service operational problems, the surveillance specimen holder tubes described in B and W topical report BAW-10051 have been redesigned. This report describes the new design and structural analysis for normal operation and upset loading conditions. The results of the analysis demonstrate the adequacy of the new surveillance specimen holder tubes for their design life of 40 years

  6. Basic data for surveillance test on core support graphite structures for the high temperature engineering test reactor (HTTR)

    International Nuclear Information System (INIS)

    Sumita, Junya; Shibata, Taiju; Kikuchi, Takayuki; Iyoku, Tatsuo; Fujimoto, Nozomu; Ishihara, Masahiro; Sawa, Kazuhiro

    2007-02-01

    Both of the visual inspection by a TV camera and the measurement of material properties by surveillance test on core support graphite structures are planned for the High Temperature Engineering Test Reactor (HTTR) to confirm their structural integrity and characteristics. The surveillance test is aimed to investigate the change of material properties by aging effects such as fast neutron irradiation and oxidation. The obtained data will be used not only for evaluating the structural integrity of the core support graphite structures of the HTTR but also for design of advanced Very High Temperature Reactor (VHTR) discussed at generation IV international forum. This report describes the initial material properties of surveillance specimens before installation and installed position of surveillance specimens in the HTTR. (author)

  7. Surveillance test of the JMTR core components

    International Nuclear Information System (INIS)

    Takeda, Takashi; Amezawa, Hiroo; Tobita, Kenji

    1986-02-01

    Surveillance test for the core components of Japan Materials Testing Reactor (JMTR) was started in 1966, and completed in 1985 without one capsule. Most of capsules in the program, except one beryllium specimens, were removed from the core, and carred out the post-irradiation tests at the JMTR Hot Laboratory. The data is applied to review of JMTR core components management plan. JMTR surveillance test was carried out with several kind of materials of JMTR core components, Berylium as the reflector, Hafnium as the neutron absorber of control rod, 17-4PH stainless steel as a roller spring of the control rod, and 304 stainless steel as the grid plate. Results are described in this report. (author)

  8. Irradiation temperature measurement of the reactor pressure vessel surveillance specimen in the programmes of radiation degradation monitoring

    International Nuclear Information System (INIS)

    Kupca, L.; Stanc, S.; Simor, S.

    2001-01-01

    The information's about the special system of irradiation temperature measurement, used for reactor pressure vessel surveillance specimen, which are placed in reactor thermal shielding canals are presented in the paper. The system was designed and realized in the frame of Extended Surveillance Specimen Programme for NPP V-2 Jaslovske Bohunice and Modern Surveillance Specimen Programme for NPP Mochovce. Base design aspects, technical parameters of realization and results of measurement on the two units in Bohunice and Mochovce NPPs are presented too. (Authors)

  9. The results of the surveillance specimen program performed in the RPVs NPP V-2 in Jaslovske Bohunice

    Energy Technology Data Exchange (ETDEWEB)

    Kupca, L; Beno, P [Vyskumny Ustav Jadrovych Elektrarni, Trnava (Slovakia); Cepeek, S [Atomova Elektraren Bohunice, Jaslovske Bohunice (Slovakia); Tomasich, M [Slovak Nuclear Society, Bratislava (Slovakia)

    1994-12-31

    After a description of the mechanical and chemical characteristics of the materials (steels, welded joints) used in the pressure vessels of the WWER-440 V-213 type, the present status of the Bohunice NPP Unit 3 and 4 pressure vessel embrittlement assessment programme is presented: neutron flux monitoring and calculations, detector accuracy, irradiation temperature monitoring, reactor core fuel loading calculation, materials, number and types of surveillance specimens, specimen testing. Results are given for 5 years of irradiation: mechanical properties, transition temperatures, lifetime evaluation. 4 refs., 13 figs., 6 tabs.

  10. Standard Guide for Conducting Supplemental Surveillance Tests for Nuclear Power Reactor Vessels, E 706 (IH)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide discusses test procedures that can be used in conjunction with, but not as alternatives to, those required by Practices E185 and E2215 for the surveillance of nuclear reactor vessels. The supplemental mechanical property tests outlined permit the acquisition of additional information on radiation-induced changes in fracture toughness, notch ductility, and yield strength properties of the reactor vessel steels. 1.2 This guide provides recommendations for the preparation of test specimens for irradiation, and identifies special precautions and requirements for reactor surveillance operations and postirradiation test planning. Guidance on data reduction and computational procedures is also given. Reference is made to other ASTM test methods for the physical conduct of specimen tests and for raw data acquisition.

  11. The analysis of reactor vessel surveillance program data

    International Nuclear Information System (INIS)

    Norris, E.B.

    1979-01-01

    Commercial nuclear power reactor vessel surveillance programs are provided by the reactor supplier and are designed to meet the requirements of ASTM Method E 185. (3). Each surveillance capsule contains sets of Charpy V-notch (Csub(v)) specimens representing selected materials from the vessel beltline region and some reference steel, tension test specimens machined from selected beltline materials, temperature monitors, and neutron flux dosimeters. Surveillance capsules may also contain fracture mechanics specimens machined from selected vessel beltline materials. The major steps in the conduct of a surveillance program include (1) the testing of the surveillance specimens to determine the exposure conditions at the capsule location and the resulting embrittlement of the vessel steel, (2) the extrapolation of the capsule results to the pressure vessel wall, and (3) the determination of the heatup and cooldown limits for normal, upset, and test operation. This paper will present data obtained from commercial light water reactor surveillance programs to illustrate the methods of analysis currently in use at Southwest Research Institute and to demonstrate some of the limitations imposed by the data available. Details concerning the procedures for testing the surveillance capsule specimens will not be included because they are considered to be outside of the scope of this paper

  12. Nuclear reactor pressure vessel surveillance capsule examinations. Application of American Society for Testing and Materials Standards

    International Nuclear Information System (INIS)

    Perrin, J.S.

    1978-01-01

    A series of pressure vessel surveillance capsules is installed in each commercial nuclear power plant in the United States. A capsule typically contains neutron dose meters, thermal monitors, tensile specimens, and Charpy V-notch impact specimens. In order to determine property changes of the pressure vessel resulting from irradiation, surveillance capsules are periodically removed during the life of a reactor and examined. There are numerous standards, regulations, and codes governing US pressure vessel surveillance capsule programmes. These are put out by the US Nuclear Regulatory Commission, the Boiler and Pressure Vessel Committee of the American Society of Mechanical Engineers, and the American Society for Testing and Materials (ASTM). A majority of the pertinent ASTM standards are under the jurisdiction of ASTM Committee E-10 on Nuclear Applications and Measurements of Radiation Effects. The standards, regulations, and codes pertaining to pressure vessel surveillance play an important role in ensuring reliability of the nuclear pressure vessels. ASTM E 185-73 is the Standard Recommended Practice for Surveillance Tests for Nuclear Reactors. This standard recommends procedures for both the irradiation and subsequent testing of surveillance capsules. ASTM E 185-73 references many additional specialized ASTM standards to be followed in specific areas of a surveillance capsule examination. A key element of surveillance capsule programmes is the Charpy V-notch impact test, used to define curves of fracture behaviour over a range of temperatures. The data from these tests are used to define the adjusted reference temperature used in determining pressure-temperature operating curves for a nuclear power plant. (author)

  13. Fracture toughness of Charpy-size compound specimens and its application in engineering

    International Nuclear Information System (INIS)

    Zhang, X.P.; Shi, Y.W.

    1994-01-01

    The use of a pre-cracked Charpy-size specimen with a side-groove to evaluate the fracture toughness of materials has been researched and considered. This method not only satisfies the demand for small-size specimens in surveillance tests of fracture toughness but also avoids using complicated physical methods to monitor the initial conditions of crack propagation. For most materials this method has solved the problem in which the small-size specimen did not satisfy the valid conditions of a fracture toughness measurement. In order to obtain more information from neutron-irradiated sample specimens and raise the reliability of fracture toughness surveillance tests, it has been considered more important to repeatedly exploit the broken Charpy-size specimen tested in the surveillance test, and to make it renewable. In this work, on the renewing design and utilization of Charpy-size specimens, nine data on fracture toughness can be obtained from one pre-cracked side-grooved Charpy-size specimen, while at present usually only one to three data on fracture toughness can be obtained from one Charpy-size specimen. Thus, it is found that the new method would improve the reliability of fracture toughness surveillance testing and evaluation. In addition, some factors that affect the optimum design of pre-cracked deep side-groove Charpy-size compound specimens have also been discussed. (author)

  14. Laser weld reconstitution of conventional Charpy and Miniaturized Notch Test (MNT) specimens

    International Nuclear Information System (INIS)

    Manahan, M.P.; Williams, J.; Martukanitz, R.P.

    1993-01-01

    As nuclear power plants approach end-of-license (EOL) and consideration is given to license renewal, there is an ever increasing need to expand the amount of data obtainable from the original surveillance specimens. A laser welding technique to reconstitute broken Charpy specimens is being developed to produce both conventional and miniaturized Charpy specimens. This paper reports on early laser welding development efforts and summarizes previous proof-of-principle experiments on a 1/16 scale miniaturized Charpy test. In order to benchmark the laser welding procedure, the laser-reconstituted specimen data have been compared with the original specimen data. In addition, the microstructure after welding has been examined to ensure that the material in the vicinity of the notch is essentially unchanged after the welding process. Data which characterize the thermal transient during welding are obtained by attaching thermocouples to the specimens. Other important considerations include perturbation of the stress field near the notch, dynamic stress waves, and contact of the weld region with the tup. Precise control of welding parameters has been demonstrated, heat-affected zones as small as 0.25 mm can be achieved, and sufficient penetration depth can be obtained to enable welding thick sections (1T or greater) to yield conventional Charpy specimens or fracture toughness specimens and thin sections (∼5 mm) to yield Miniaturized Notch Test (MNT) specimens

  15. Reactor Vessel Surveillance Program for Advanced Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Kyeong-Hoon; Kim, Tae-Wan; Lee, Gyu-Mahn; Kim, Jong-Wook; Park, Keun-Bae; Kim, Keung-Koo

    2008-10-15

    This report provides the design requirements of an integral type reactor vessel surveillance program for an integral type reactor in accordance with the requirements of Korean MEST (Ministry of Education, Science and Technology Development) Notice 2008-18. This report covers the requirements for the design of surveillance capsule assemblies including their test specimens, test block materials, handling tools, and monitors of the surveillance capsule neutron fluence and temperature. In addition, this report provides design requirements for the program for irradiation surveillance of reactor vessel materials, a layout of specimens and monitors in the surveillance capsule, procedures of installation and retrieval of the surveillance capsule assemblies, and the layout of the surveillance capsule assemblies in the reactor.

  16. Evaluation of HFIR vessel surveillance data and hydro-test conditions

    International Nuclear Information System (INIS)

    Cheverton, R.D.; Nanstad, R.K.

    1994-01-01

    Surveillance specimens for the High Flux Isotope Reactor (HFIR) pressure vessel were removed and tested during 1993, after the vessel had accumulated 701,469 MWd of operation. The data agree well with HFIR surveillance data obtained in previous years. In conjunction with this effort, the vessel hydro-test conditions were reevaluated and found to be more than adequate. In view of this result, and because there are economic incentives for reducing the frequency of hydro testing, an analysis was performed to determine the minimum permissible frequency. The value obtained is substantially less than that presently specified. It was also determined that a somewhat lower cooling-tower-basin temperature is acceptable (improves operational flexibility). In 1986, after ∼20 years of reactor operation, it was discovered that the vessel embrittlement rate was substantially greater than expected. Possible reasons for the accelerated rate are reviewed in this report

  17. Including test errors in evaluating surveillance test intervals

    International Nuclear Information System (INIS)

    Kim, I.S.; Samanta, P.K.; Martorell, S.; Vesely, W.E.

    1991-01-01

    Technical Specifications require surveillance testing to assure that the standby systems important to safety will start and perform their intended functions in the event of plant abnormality. However, as evidenced by operating experience, the surveillance tests may be adversely impact safety because of their undesirable side effects, such as initiation of plant transients during testing or wearing-out of safety systems due to testing. This paper first defines the concerns, i.e., the potential adverse effects of surveillance testing, from a risk perspective. Then, we present a methodology to evaluate the risk impact of those adverse effects, focusing on two important kinds of adverse impacts of surveillance testing: (1) risk impact of test-caused trips and (2) risk impact of test-caused equipment wear. The quantitative risk methodology is demonstrated with several surveillance tests conducted at boiling water reactors, such as the tests of the main steam isolation valves, the turbine overspeed protection system, and the emergency diesel generators. We present the results of the risk-effectiveness evaluation of surveillance test intervals, which compares the adverse risk impact with the beneficial risk impact of testing from potential failure detection, along with insights from sensitivity studies

  18. Splitting tests on rock specimens

    Energy Technology Data Exchange (ETDEWEB)

    Davies, J D; Stagg, K G

    1970-01-01

    Splitting tests are described for a square-section sandstone specimens line loaded through steel or timber packings on the top face and supported on the bottom face either on similar packings (type A specimen) or directly on the lower platen plate of the testing machine (type B specimens). The stress distribution across the vertical central plane and the horizontal central plane were determined from a linear elastic finite element analysis for both types. Two solutions were obtained for the type B specimen: one assuming no friction between the base of the specimen and the platen plate and the other assuming no relative slip between the surfaces. Vertical and horizontal strains were measured at the center of the specimens for all loads up to failure.

  19. Surveillance test of OWL-2 inpile tube

    International Nuclear Information System (INIS)

    Shimizu, Masatsugu; Itoh, Noboru

    1976-08-01

    A series of irradiation surveillance tests performed in integrity evaluation of an inpile tube for the test loop OWL-2 are described. Specimens were exposed to the neutron fluences from 1 x 10 20 to 3.4 x 10 21 n/cm 2 (>1 MeV), and subjected to post-irradiation tensile test at room temperature and service temperature 285 0 C. The strength increased and the ductility decreased with increasing neutron fluence. The reduction in fracture ductility due to neutron irradiation in the fluence range was insignificant, and the elongation of 33% was retained even for the maximum neutron fluence at 285 0 C. Little decrease of the ductility with fluence indicates that the tube would be in service for long time, ie to the integral fluence of 3.4 x 10 21 n/cm 2 . (auth.)

  20. Nanostructural evolution in surveillance test specimens of a commercial nuclear reactor pressure vessel studied by three-dimensional atom probe and positron annihilation

    International Nuclear Information System (INIS)

    Toyama, T.; Nagai, Y.; Tang, Z.; Hasegawa, M.; Almazouzi, A.; Walle, E. van; Gerard, R.

    2007-01-01

    The nanostructural evolution of irradiation-induced Cu-rich nanoprecipitates (CRNPs) and vacancy clusters in surveillance test specimens of in-service commercial nuclear reactor pressure vessel steel welds of Doel-1 and Doel-2 are revealed by combining the three-dimensional local electrode atom probe and positron annihilation techniques. In both medium (0.13 wt.%) and high (0.30 wt.%) Cu welds, the CRNPs are found to form readily at the very beginning of the reactor lifetime. Thereafter, during the subsequent 30 years of operation, the residual Cu concentration in the matrix shows a slight decrease while the CRNPs coarsen. On the other hand, small vacancy clusters of V 3 -V 4 start appearing after the initial Cu precipitation and accumulate steadily with increasing neutron dose. The observed nanostructural evolution is shown to provide unique and fundamental information about the mechanisms of the irradiation-induced embrittlement of these specific materials

  1. Dosimetry of VVER-1000 Reactor Pressure Vessel and Surveillance Specimens as a part of PLiM at Ukrainian NPPs

    International Nuclear Information System (INIS)

    Bukanov, V.N.; Diemokhin, V.L.; Grytsenko, O.V.; Ilkovych, V.V.; Pugach, A.M.; Pugach, S.M.; Vasylieva, O.G.; Vyshnevskyi, I.M.; Kasatkin, O.G.

    2012-01-01

    A regular surveillance program for VVER-1000 and its shortages are described. The Methodology for determination of neutron flux functionals on surveillance specimens of VVER-1000 pressure vessel is presented. The radiation exposure monitoring system for VVER-1000 pressure vessel is described. The main principles of an additional surveillance program for VVER-1000 are presented. The Dosimetry Experiment, which is already carrying out at Unit 3 of Rivne NPP, is described. (author)

  2. Surveillance extension experience at WWER-440 type reactors

    International Nuclear Information System (INIS)

    Gillemot, F.; Uri, G.; Oszwald, F.; Trampus, P.

    1993-01-01

    In WWER-440 reactors, the surveillance specimens are located in accelerated irradiation positions. After 5 years, all specimens are withdrawn and the operational changes are not monitored. At Paks NPP a new surveillance program extension has been settled in order to avoid these original program disadvantages and generate further data for plant lifetime management. This paper includes: research performed to prepare the surveillance extension programme, the evaluation method for the surveillance extension, and first results (Charpy and tensile tests). (authors). 6 refs., 12 figs., 3 tabs

  3. Surveillance extension experience at WWER-440 type reactors

    Energy Technology Data Exchange (ETDEWEB)

    Gillemot, F; Uri, G [Budapesti Mueszaki Egyetem, Budapest (Hungary); Oszwald, F; Trampus, P

    1994-12-31

    In WWER-440 reactors, the surveillance specimens are located in accelerated irradiation positions. After 5 years, all specimens are withdrawn and the operational changes are not monitored. At Paks NPP a new surveillance program extension has been settled in order to avoid these original program disadvantages and generate further data for plant lifetime management. This paper includes: research performed to prepare the surveillance extension programme, the evaluation method for the surveillance extension, and first results (Charpy and tensile tests). (authors). 6 refs., 12 figs., 3 tabs.

  4. Analysis of the surveillance test data on irradiation embrittlement of the reactor pressure vessel steels in LWRs

    International Nuclear Information System (INIS)

    Lee, Gyoeng Geun; Kwon, Jun Hyun

    2010-11-01

    The surveillance test data in Korean LWRs were analyzed from a viewpoint of materials science. TTS change with the neutron irradiation were compared to the model values of the RG1.99/2 and NUREG/CR-6551. The model values of TTS were higher than the actual values of TTS. It was impossible to find a relationship between TTS and neutron fluence in weld data. The correlation of the increase in YS (yield strength) and TTS with neutron irradiation was also investigated. Like the result of TTS change, the YS/TTS showed the correlations in plate/forgings metals, however no correlation in weld metals. The data were similar to Odette's result about US surveillance tests. From the empirical relationships, the TTS curve change could be predicted using the CVN test result of the unirradiated specimen and the change in YS with neutron irradiation of the specimen

  5. Evaluation of A-1 reactor heavy-water calandria specimens

    International Nuclear Information System (INIS)

    Brumovsky, M.

    1976-01-01

    Container chains with surveillance specimens were placed in two special channels of the core peripheral part to test changes in mechanical properties due to reactor operation of caisson tube material. The specimens were made from the caisson tube material and placed by eight pieces on the outer surface of the containers. The first removed specimens were tested for corrosion losses, tensile strength, and fractured surfaces were then assessed. The changes in strength properties were found to be similar in both base material and welded joints. The corrosion film on surveillance specimens did not practically affect strength properties nor ductility. It was found that the Al-Mg-Si alloy used for the heavy water vessel caisson tubes following stabilization annealing was fully stable at operating temperatures of up to 100 degC. Slio.ht changes in properties can be attributed to the effect of a high neutron dose. Thus, the high radiation and temperature stability of the alloy was confirmed. (O.K.)

  6. Recent advances on Charpy specimen reconstitution techniques

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Arnaldo H.P.; Lobo, Raquel M.; Miranda, Carlos Alexandre J., E-mail: aandrade@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    Charpy specimen reconstitution is widely used around the world as a tool to enhance or supplement surveillance programs of nuclear reactor pressure vessels. The reconstitution technique consists in the incorporation of a small piece from a previously tested specimen into a compound specimen, allowing to increase the number of tests. This is especially important if the available materials is restricted and fracture mechanics parameter have to be determined. The reconstitution technique must fulfill some demands, among them tests results like the original standard specimens and the loaded material of the insert must not be influenced by the welding and machining procedure. It is known that reconstitution of Charpy specimens may affect the impact energy in a consequence of the constraint of plastic deformation by the hardened weldment and HAZ. This paper reviews some recent advances of the reconstitution technique and its applications. (author)

  7. Recent advances on Charpy specimen reconstitution techniques

    International Nuclear Information System (INIS)

    Andrade, Arnaldo H.P.; Lobo, Raquel M.; Miranda, Carlos Alexandre J.

    2017-01-01

    Charpy specimen reconstitution is widely used around the world as a tool to enhance or supplement surveillance programs of nuclear reactor pressure vessels. The reconstitution technique consists in the incorporation of a small piece from a previously tested specimen into a compound specimen, allowing to increase the number of tests. This is especially important if the available materials is restricted and fracture mechanics parameter have to be determined. The reconstitution technique must fulfill some demands, among them tests results like the original standard specimens and the loaded material of the insert must not be influenced by the welding and machining procedure. It is known that reconstitution of Charpy specimens may affect the impact energy in a consequence of the constraint of plastic deformation by the hardened weldment and HAZ. This paper reviews some recent advances of the reconstitution technique and its applications. (author)

  8. Guidebook for the fabrication of non-destructive testing (NDT) test specimens

    International Nuclear Information System (INIS)

    2001-01-01

    Non-destructive testing (NDT) test specimens constitute a very important part of training and certification of NDT personnel and are important for carrying out actual inspection and testing, and for achieving international harmonization of NDT practices. The IAEA organized an advisory group of experts to develop a Guidebook for Fabrication of NDT Test Specimens. The experts consulted the ISO/FDIS 9712-1999 requirements for training and certification of personnel and the suitability of various types of NDT test specimens that are needed to meet such requirements This guidebook presents a set of NDT test specimens, and the methodology and procedures for their fabrication

  9. Thermal property testing technique on micro specimen

    International Nuclear Information System (INIS)

    Baba, Tetsuya; Kishimoto, Isao; Taketoshi, Naoyuki

    2000-01-01

    This study aims at establishment of further development on some testing techniques on the nuclear advanced basic research accumulated by the National Research Laboratory of Metrology for ten years. For this purpose, a technology to test heat diffusion ratio and specific heat capacity of less than 3 mm in diameter and 1 mm in thickness of micro specimen and technology to test heat diffusion ratio at micro area of less than 1 mm in area along cross section of less than 10 mm in diameter of column specimen were developed to contribute to common basic technology supporting the nuclear power field. As a result, as an element technology to test heat diffusion ratio and specific heat capacity of the micro specimen, a specimen holding technique stably to hold a micro specimen with 3 mm in diameter could be developed. And, for testing the specific heat capacity by using the laser flush differential calorimetry, a technique to hold two specimen of 5 mm in diameter at their proximities was also developed. In addition, by promoting development of thermal property data base capable of storing thermal property data obtained in this study and with excellent workability in this 1998 fiscal year a data in/out-put program with graphical user interface could be prepared. (G.K.)

  10. A new method for improving the reliability of fracture toughness surveillance of nuclear pressure vessel by neutron irradiated embrittlement

    International Nuclear Information System (INIS)

    Zhang Xinping; Shi Yaowu

    1992-01-01

    In order to obtain more information from neutron irradiated sample specimens and raise the reliability of fracture toughness surveillance test, it has more important significance to repeatedly exploit the broken Charpy-size specimen which had been tested in surveillance test. In this work, on the renewing design and utilization for Charpy-size specimens, 9 data of fracture toughness can be gained from one pre-cracked side-grooved Charpy-size specimen while at the preset usually only 1 to 3 data of fracture toughness can be obtained from one Chharpy-size specimen. Thus, it is found that the new method would obviously improve the reliability of fracture toughness surveillance test and evaluation. Some factors which affect the reasonable design of pre-cracked deep side-groove Charpy-size compound specimen have been discussed

  11. Extended surveillance as a support to PLIM

    International Nuclear Information System (INIS)

    Walle, Eric van

    2002-01-01

    Full text: The safe exploitation of the reactor pressure vessel was and is always a major concern in nuclear power plant life management. At present, issues like Plant Life Extension, where utilities look into the possibility of license renewal after 40 years of operation, are becoming relevant in the USA. In other countries PLIM beyond the design life of the NPP could also be desirable from the economic viewpoint. The limiting factor could, however, be the integrity of the reactor pressure vessel. The reactor pressure vessel surveillance procedures as defined by regulatory legislation is limited and can be supplemented with valuable information that can be extracted in parallel to conventional surveillance testing or through additional testing on surveillance material. This is justified for several reasons: 1. The current methodology is semi-empirical, contains flaws and is in a number of cases over conservative. Without giving in on safety, we need to try and understand the material behavior more fundamentally; 2. Some reactor surveillance materials demonstrate inconsistent behavior with respect to the overall trend. These materials are called 'outlier' materials. But are they really outliers or is this connected to the indexing methodology used? 3. Additional data, for example the results of instrumented Charpy-V impact tests, have been obtained on many surveillance test specimens and are not adequately exploited in the actual surveillance methodology; 4. Scientific research provides substantial information and understanding of degradation mechanisms in reactor pressure vessel steels. Although we will not concentrate on this topic, the development of powerful microscopic investigation techniques, like FEGSTEM, APFIM, SANS, positron annihilation, internal friction, ... led to an intensified development of radiation damage modelling and are an input to micromechanical modelling. Moreover, due to the ever increasing computer power, additional multi-scale (time and

  12. Molecular changes preceding endometrial and ovarian cancer: a study of consecutive endometrial specimens from Lynch syndrome surveillance.

    Science.gov (United States)

    Niskakoski, Anni; Pasanen, Annukka; Lassus, Heini; Renkonen-Sinisalo, Laura; Kaur, Sippy; Mecklin, Jukka-Pekka; Bützow, Ralf; Peltomäki, Päivi

    2018-03-27

    Molecular alterations preceding endometrial and ovarian cancer and the sequence of events are unknown. Consecutive specimens from lifelong surveillance for Lynch syndrome provides a natural setting to address such questions. To molecularly define the multistep gynecological tumorigenesis, DNA mismatch repair gene mutation carriers with endometrial or ovarian carcinoma or endometrial hyperplasia were identified from a nation-wide registry and endometrial biopsy specimens taken from these individuals during 20 years of screening were collected. A total of 213 endometrial and ovarian specimens from Lynch syndrome individuals and 197 histology-matched (non-serous) samples from sporadic cases were available for this investigation. The specimens were profiled for markers linked to endometrial and ovarian tumorigenesis, including ARID1A protein expression, mismatch repair status, and tumor suppressor gene promoter methylation. In Lynch syndrome-associated endometrial and ovarian carcinomas, ARID1A protein was lost in 61-100% and mismatch repair was deficient in 97-100%, compared to 0-17% and 14-44% in sporadic cases (P = 0.000). ARID1A loss appeared in complex hyperplasia and deficient mismatch repair and tumor suppressor gene promoter methylation in histologically normal endometrium. Despite quantitative differences between Lynch syndrome and sporadic cases, ARID1A expression, mismatch repair, and tumor suppressor gene promoter methylation divided endometrial samples from both patient groups into three categories of increasing abnormality, comprising normal endometrium and simple hyperplasia (I), complex hyperplasia with or without atypia (II), and endometrial cancer (III). Complex hyperplasias without vs. with atypia were molecularly indistinguishable. In conclusion, surveillance specimens from Lynch syndrome identify mismatch repair deficiency, tumor suppressor gene promoter methylation, and ARID1A loss as early changes in tumor development. Our findings are

  13. Poliovirus surveillance by examining sewage specimens. Quantitative recovery of virus after introduction into sewerage at remote upstream location.

    Science.gov (United States)

    Hovi, T; Stenvik, M; Partanen, H; Kangas, A

    2001-08-01

    In order to assess the feasibility of environmental poliovirus surveillance, known amounts of poliovirus type 1, strain Sabin, were flushed into the sewage network of Helsinki. Grab specimens collected at a remote downstream location and concentrated about a 100-fold revealed infectious poliovirus on four successive days in all three separate experiments. As for concentration, a simple two-phase separation method was found to be at least as useful as a several-fold more resource-demanding polyethylene glycol (PEG) precipitation method. Recovery of the introduced virus was remarkably high (more than 10%). Using the current system, it might be possible to detect poliovirus circulation in a population of 700,000 people by examining a single 400 ml sewage specimen, if 1 out of 10,000 inhabitants were excreting the virus. It is concluded that environmental surveillance is a sensitive approach to monitor silent poliovirus circulation in populations served by a sewage network.

  14. Evaluation of the novel respiratory virus surveillance program: Pediatric Early Warning Sentinel Surveillance (PEWSS).

    Science.gov (United States)

    Armour, Patricia A; Nguyen, Linh M; Lutman, Michelle L; Middaugh, John P

    2013-01-01

    Infections caused by respiratory viruses are associated with recurrent epidemics and widespread morbidity and mortality. Routine surveillance of these pathogens is necessary to determine virus activity, monitor for changes in circulating strains, and plan for public health preparedness. The Southern Nevada Health District in Las Vegas, Nevada, recruited five pediatric medical practices to serve as sentinel sites for the Pediatric Early Warning Sentinel Surveillance (PEWSS) program. Sentinel staff collected specimens throughout the year from ill children who met the influenza-like illness case definition and submitted specimens to the Southern Nevada Public Health Laboratory for molecular testing for influenza and six non-influenza viruses. Laboratory results were analyzed and reported to the medical and general communities in weekly bulletins year-round. PEWSS data were also used to establish viral respiratory seasonal baselines and in influenza vaccination campaigns. The surveillance program was evaluated using the Centers for Disease Control and Prevention's (CDC's) Updated Guidelines for Evaluating Public Health Surveillance Systems. PEWSS met three of six program usefulness criteria and seven of nine surveillance system attributes, which exceeded the CDC Guidelines evaluation criteria for a useful and complete public health surveillance program. We found that PEWSS is a useful and complete public health surveillance system that is simple, flexible, accessible, and stable.

  15. Risk effectiveness evaluation of surveillance testing

    International Nuclear Information System (INIS)

    Kim, I.S.; Samanta, P.K.; Martorell, S.; Vesely, W.E.

    1991-01-01

    To address the concerns about nuclear power plant surveillance tests, i.e., their adverse safety impact due to negative effects and too burdensome requirements, it is necessary to evaluate the safety significance or risk effectiveness of such tests explicitly considering both negative and positive effects. This paper defines the negative effects of surveillance testing from a risk perspective, and then presents a methodology to quantify the negative risk impact, i.e., the risk penalty or risk increase caused by the test. The method focuses on two important kinds of negative effects, namely, test-caused transients and test-caused equipment degradations. The concepts and quantitative methods for the risk evaluation can be used in the decision-making process to establish the safety significance of the tests and to screen the plant-specific surveillance test requirements. 6 refs., 2 figs., 2 tabs

  16. Integrity assessment of TAPS reactor pressure vessel at extended EOL using surveillance test results

    International Nuclear Information System (INIS)

    Chatterjee, S.; Shah, Priti Kotak

    2008-05-01

    Integrity assessment of pressure vessels of nuclear reactors (RPV) primarily concentrates on the prevention of brittle failure and conditions are defined under which brittle failure can be excluded. Accordingly, two approaches based on Transition Temperature Concept and Fracture Mechanics Concept were adopted using the impact test results of three credible surveillance data sets obtained from the surveillance specimens of Tarapur Atomic Power Station. RT NDT data towards end of life (EOL) were estimated from the impact test results in accordance with the procedures of USNRC Regulatory Guide 1.99, Rev. 2 and were used as primary input for assessment of the vessel integrity. SA302B (nickel modified) steel cladded with stainless steel is used as the pressure vessel material for the two 210 MWe boiling water reactors of the Tarapur Atomic Power Station (TAPS). The reactors were commissioned during the year 1969. The chemical compositions of SA302B (modified) steel used in fabricating the vessel and the specified tensile property and the Charpy impact property requirements of the steel broadly meet ASME specified requirements. Therefore, the pressure temperature limit curves prescribed by General Electric (G.E.) were compared with those as obtained using procedures of ASME Section XII, Appendix G. The tensile and the Charpy impact properties at 60 EFPY of vessel operation as derived from the surveillance specimens even fulfilled the specified requirements for the virgin material of ASME. Integrity assessment carried out using the two approaches indicated the safety of the vessel for continued operation up to 60 EFPY. (author)

  17. Urine specimen validity test for drug abuse testing in workplace and court settings.

    Science.gov (United States)

    Lin, Shin-Yu; Lee, Hei-Hwa; Lee, Jong-Feng; Chen, Bai-Hsiun

    2018-01-01

    In recent decades, urine drug testing in the workplace has become common in many countries in the world. There have been several studies concerning the use of the urine specimen validity test (SVT) for drug abuse testing administered in the workplace. However, very little data exists concerning the urine SVT on drug abuse tests from court specimens, including dilute, substituted, adulterated, and invalid tests. We investigated 21,696 submitted urine drug test samples for SVT from workplace and court settings in southern Taiwan over 5 years. All immunoassay screen-positive urine specimen drug tests were confirmed by gas chromatography/mass spectrometry. We found that the mean 5-year prevalence of tampering (dilute, substituted, or invalid tests) in urine specimens from the workplace and court settings were 1.09% and 3.81%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the workplace were 89.2%, 6.8%, and 4.1%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the court were 94.8%, 1.4%, and 3.8%, respectively. No adulterated cases were found among the workplace or court samples. The most common drug identified from the workplace specimens was amphetamine, followed by opiates. The most common drug identified from the court specimens was ketamine, followed by amphetamine. We suggest that all urine specimens taken for drug testing from both the workplace and court settings need to be tested for validity. Copyright © 2017. Published by Elsevier B.V.

  18. Advanced neutron source materials surveillance program

    International Nuclear Information System (INIS)

    Heavilin, S.M.

    1995-01-01

    The Advanced Neutron Source (ANS) will be composed of several different materials, one of which is 6061-T6 aluminum. Among other components, the reflector vessel and the core pressure boundary tube (CPBT), are to be made of 6061-T6 aluminum. These components will be subjected to high thermal neutron fluences and will require a surveillance program to monitor the strength and fracture toughness of the 6061-T6 aluminum over their lifetimes. The purpose of this paper is to explain the steps that were taken in the summer of 1994 toward developing the surveillance program. The first goal was to decide upon standard specimens to use in the fracture toughness and tensile testing. Second, facilities had to be chosen for specimens representing the CPBT and the reflector vessel base, weld, and heat-affected-zone (HAZ) metals. Third, a timetable had to be defined to determine when to remove the specimens for testing

  19. Some recent innovations in small specimen testing

    International Nuclear Information System (INIS)

    Odette, G.R.; He, M.; Gragg, D.; Klingensmith, D.; Lucas, G.E.

    2002-01-01

    New innovative small specimen test techniques are described. Finite element simulations show that combinations of cone indentation pile-up geometry and load-penetration depth relations can be used to determine both the yield stress and strain-hardening behavior of a material. Techniques for pre-cracking and testing sub-miniaturized fracture toughness bend bars, with dimensions of 1.65x1.65x9 mm 3 , or less, are described. The corresponding toughness-temperature curves have a very steep transition slope, primarily due to rapid loss of constraint, which has advantages in some experiments to characterize the effects of specified irradiation variables. As one example of using composite specimens, an approach to evaluating helium effects is proposed, involving diffusion bonding small wires of a 54 Fe-based ferritic-martensitic alloy to a surrounding fracture specimen composed of an elemental Fe-based alloy. Finally, we briefly outline some potential approaches to multipurpose specimens and test automation

  20. Tensile-Creep Test Specimen Preparation Practices of Surface Support Liners

    Science.gov (United States)

    Guner, Dogukan; Ozturk, Hasan

    2017-12-01

    Ground support has always been considered as a challenging issue in all underground operations. Many forms of support systems and supporting techniques are available in the mining/tunnelling industry. In the last two decades, a new polymer based material, Thin Spray-on Liner (TSL), has attained a place in the market as an alternative to the current areal ground support systems. Although TSL provides numerous merits and has different application purposes, the knowledge on mechanical properties and performance of this material is still limited. In laboratory studies, since tensile rupture is the most commonly observed failure mechanism in field applications, researchers have generally studied the tensile testing of TSLs with modification of American Society for Testing and Materials (ASTM) D-638 standards. For tensile creep testing, specimen preparation process also follows the ASTM standards. Two different specimen dimension types (Type I, Type IV) are widely preferred in TSL tensile testing that conform to the related standards. Moreover, molding and die cutting are commonly used specimen preparation techniques. In literature, there is a great variability of test results due to the difference in specimen preparation techniques and practices. In this study, a ductile TSL product was tested in order to investigate the effect of both specimen preparation techniques and specimen dimensions under 7-day curing time. As a result, ultimate tensile strength, tensile yield strength, tensile modulus, and elongation at break values were obtained for 4 different test series. It is concluded that Type IV specimens have higher strength values compared to Type I specimens and moulded specimens have lower results than that of prepared by using die cutter. Moreover, specimens prepared by molding techniques have scattered test results. Type IV specimens prepared by die cutter technique are suggested for preparation of tensile test and Type I specimens prepared by die cutter technique

  1. Tension test system for irradiated small specimens operated by remote control

    International Nuclear Information System (INIS)

    Okada, Akira

    1993-01-01

    A robot-based tension test system has been developed to aid in the mechanical testing of highly radioactive specimens. This system reduces radiation hazards from specimens and allows for the uniform precision of testing results independent of experimenters' skills. The robot system is designed to accommodate a miniaturized tension specimen with a gage section 5.5 by 1.2 mm, with a total length and width of 12.5 and 2.3 mm, respectively, and thickness of about 0.2 mm. The system is composed of a manipulating robot, a vibrational-type specimen feeder, a rotating-type specimen tray, a specimen observation system, a simulated tension text fixture, and a microcomputer for controlling the system. This system accomplishes specimen arrangement in the specimen tray, specimen transportation and loading to the test fixture and testing, and removal of the broken specimen from the fixture. These procedures are performed quickly, safely, and with uniform testing precision by computer control remotely by an unskilled experimenter

  2. LWR surveillance dosimetry improvement program: PSF metallurgical blind test results

    International Nuclear Information System (INIS)

    Kam, F.B.K.; Maerker, R.E.; Stallmann, F.W.

    1984-01-01

    The metallurgical irradiation experiment at the Oak Ridge Research Reactor Poolside Facility (ORR-PSF) was designed as a benchmark to test the accuracy of radiation embrittlement predictions in the pressure vessel wall of light water reactors on the basis of results from surveillance capsules. The PSF metallurgical Blind Test is concerned with the simulated surveillance capsule (SSC) and the simulated pressure vessel capsule (SPVC). The data from the ORR-PSF benchmark experiment are the basis for comparison with the predictions made by participants of the metallurgical ''Blind Test''. The Blind Test required the participants to predict the embrittlement of the irradiated specimen based only on dosimetry and metallurgical data from the SSC1 capsule. This exercise included both the prediction of damage fluence and the prediction of embrittlement based on the predicted fluence. A variety of prediction methodologies was used by the participants. No glaring biases or other deficiencies were found, but neither were any of the methods clearly superior to the others. Closer analysis shows a rather complex and poorly understood relation between fluence and material damage. Many prediction formulas can give an adequate approximation, but further improvement of the prediction methodology is unlikely at this time given the many unknown factors. Instead, attention should be focused on determining realistic uncertainties for the predicted material changes. The Blind Test comparisons provide some clues for the size of these uncertainties. In particular, higher uncertainties must be assigned to materials whose chemical composition lies outside the data set for which the prediction formula was obtained. 16 references, 14 figures, 5 tables

  3. Specimen size effects in Charpy impact testing

    International Nuclear Information System (INIS)

    Alexander, D.J.; Klueh, R.L.

    1989-01-01

    Full-size , half-size, and third-size specimens from several different steels have been tested as part of an ongoing alloy development program. The smaller specimens permit more specimens to be made from small trail heats and are much more efficient for irradiation experiments. The results of several comparisons between the different specimen sizes have shown that the smaller specimens show qualitatively similar behavior to large specimens, although the upper-shelf energy level and ductile-to-ductile transition temperature are reduced. The upper-shelf energy levels from different specimen sizes can be compared by using a simple volume normalization method. The effect of specimen size and geometry on the ductile-to-ductile transition temperature is more difficult to predict, although the available data suggest a simple shift in the transition temperature due to specimen size changes.The relatively shallower notch used in smaller specimens alters the deformation pattern, and permits yielding to spread back to the notched surface as well as through to the back. This reduces the constraint and the peak stresses, and thus the initiation of cleavage is more difficult. A better understanding of the stress and strain distributions is needed. 19 refs., 3 figs., 3 tabs

  4. Progress Report on Alloy 617 Notched Specimen Testing

    Energy Technology Data Exchange (ETDEWEB)

    McMurtrey, Michael David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Wright, Richard Neil [Idaho National Lab. (INL), Idaho Falls, ID (United States); Lillo, Thomas Martin [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-08-01

    Creep behavior of Alloy 617 has been extensively characterized to support the development of a draft Code Case to qualify Alloy 617 in Section III division 5 of the ASME Boiler and Pressure Vessel Code. This will allow use of Alloy 617 in construction of nuclear reactor components at elevated temperatures and longer periods of time (up to 950°C and 100,000 hours). Prior to actual use, additional concerns not considered in the ASME code need to be addressed. Code Cases are based largely on uniaxial testing of smooth gage specimens. In service conditions, components will generally be under multi axial loading. There is also the concern of the behavior at discontinuities, such as threaded components. To address the concerns of multi axial creep behavior and at geometric discontinuities, notched specimens have been designed to create conditions representative of the states that service components experience. Two general notch geometries have been used for these series of tests: U notch and V notch specimens. The notches produce a tri axial stress state, though not uniform across the specimen. Characterization of the creep behavior of the U notch specimens and the creep rupture behavior of the V notch specimens provides a good approximation of the behavior expected of actual components. Preliminary testing and analysis have been completed and are reported in this document. This includes results from V notch specimens tested at 900°C and 800°C. Failure occurred in the smooth gage section of the specimen rather than at the root of the notch, though some damage was present at the root of the notch, where initial stress was highest. This indicates notch strengthening behavior in this material at these temperatures.

  5. Improved PID control for triaxial testing liquefied specimen

    DEFF Research Database (Denmark)

    Sabaliauskas, Tomas; Ibsen, Lars Bo

    Using a frictionless triaxial apparatus, sand specimens can be tested at relatively high axial strains, even while liquefying. However, liquefying specimens have extremely nonlinear stiffness, thus standard PID control does not perform well. To maintain control over applied loads, the PID...... controller was modified to adapt to disturbed soil states. The proposed methods expand the scope of testing towards options which are otherwise inaccessible by triaxial testing....

  6. 46 CFR 57.06-4 - Production testing specimen requirements.

    Science.gov (United States)

    2010-10-01

    ... WELDING AND BRAZING Production Tests § 57.06-4 Production testing specimen requirements. (a) For test... 46 Shipping 2 2010-10-01 2010-10-01 false Production testing specimen requirements. 57.06-4... to welding shall not throw the finished test plate out of line by an angle of over 5°. (c) Where the...

  7. Post-deformation examination of specimens subjected to SCC testing

    Energy Technology Data Exchange (ETDEWEB)

    Gussev, Maxim N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Field, Kevin G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Busby, Jeremy T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Leonard, Keith J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-09-01

    This report details the results of post-radiation and post-deformation characterizations performed during FY 2015–FY 2016 on a subset of specimens that had previously been irradiated at high displacement per atom (dpa) damage doses. The specimens, made of commercial austenitic stainless steels and alloys, were subjected to stress-corrosion cracking tests (constant extension rate testing and crack growth testing) at the University of Michigan under conditions typical of nuclear power plants. After testing, the specimens were returned to Oak Ridge National Laboratory (ORNL) for further analysis and evaluation.

  8. Estimation of RPV material embrittlement for Ukrainian NPP based on surveillance test data

    International Nuclear Information System (INIS)

    Revka, V.; Chyrko, L.; Chaikovsky, Yu.; Gulchuk, Yu.

    2012-01-01

    The WWER-1000 RPV material embrittlement has been evaluated using the surveillance test data for the nuclear power plant which is under operation in Ukraine. The RPV materials after the neutron (E > 0,5 MeV) irradiation up to fluence of 22,9.10 22 m -2 have been studied. Fracture toughness tests were performed using pre-cracked Charpy specimens for the beltline materials (base and weld metal). The maximum shift of T 0 reference temperature is equal to 44 o C. A radiation embrittlement rate, A F , for the RPV materials was estimated using the standard and reconstituted specimens. A comparison of the A F values has shown a good agreement between the specimen sets before and after reconstitution both for base and weld metal. Furthermore it has been revealed there is no nickel effect for the studied materials. In spite of the high nickel content the radiation embrittlement rate for weld metal is not higher than for base metal with low nickel content. Fracture toughness analysis has shown the Master curve shape describes well a temperature dependence of K Jc values. However a higher scatter of K Jc values is observed in comparison to 95 % tolerance bounds. (author)

  9. Instrumented impact testing machine with reduced specimen oscillation effects

    International Nuclear Information System (INIS)

    Rintamaa, R.; Rahka, K.; Wallin, K.

    1984-07-01

    Owing to small and inexpensive specimens the Charpy impact test is widely used in quality control and alloy development. Limitations in power reactor survellance capsules it is also widely used for safety analysis purposes. Instrumenting the tup and computerizing data acquisition, makes dynamic fracture mechanics data measurement possible and convenient. However, the dynamic effects (inertia forces, specimen oscillations) in the impact test cause inaccuracies in the recorded load-time diagram and hence diminish the reliability of the calculated dynamic fracture mechanics parameters. To decrease inaccuracies a new pendulum type of instrumented impact test apparatus has been developed and constructed in the Metals Laboratory of the Technical Research Centre of Finland. This tester is based on a new principle involving inverted test geometry. The purpose of the geometry inversion is to reduce inertia load and specimen oscillation effects. Further, the new impact tester has some other novel features: e.g. the available initia impact energy is about double compared to the conventional standard (300 J) impact tester allowing the use of larger (10 x 20 x 110 mm) bend specimens than normal Charpy specimens. Also, the rotation asix in the three point bending is nearly stationary making COD-measurements possible. An experimental test series is described in which the inertia effects and specimen oscillations are compared in the conventional and new impact tester utilizing Charpy V-notch specimens. Comparison of the two test geometries is also made with the aid of an analytical model using finite element method (FEM) analysis. (author)

  10. Standard practice for fracture testing with surface-crack tension specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This practice covers the design, preparation, and testing of surface-crack tension (SCT) specimens. It relates specifically to testing under continuously increasing force and excludes cyclic and sustained loadings. The quantity determined is the residual strength of a specimen having a semielliptical or circular-segment fatigue crack in one surface. This value depends on the crack dimensions and the specimen thickness as well as the characteristics of the material. 1.2 Metallic materials that can be tested are not limited by strength, thickness, or toughness. However, tests of thick specimens of tough materials may require a tension test machine of extremely high capacity. The applicability of this practice to nonmetallic materials has not been determined. 1.3 This practice is limited to specimens having a uniform rectangular cross section in the test section. The test section width and length must be large with respect to the crack length. Crack depth and length should be chosen to suit the ultimate pu...

  11. Fracture Testing with Surface Crack Specimens. [especially the residual tensile strength test

    Science.gov (United States)

    Orange, T. W.

    1974-01-01

    Recommendations are given for the design, preparation, and static fracture testing of surface crack specimens. The recommendations are preceded by background information including discussions of stress intensity factors, crack opening displacements, and fracture toughness values associated with surface crack specimens. Cyclic load and sustained load tests are discussed briefly.

  12. A proposed standard round compact specimen for plane strain fracture toughness testing

    Science.gov (United States)

    Underwood, J. H.; Newman, J. C., Jr.; Seeley, R. R.

    1980-01-01

    A round, disk-shaped specimen is proposed as a standard test specimen for addition to ASTM Test for Plane-Strain Fracture Toughness of Metallic Materials (E 399-78A). The specimen is diametrically cracked, and loaded in the same way as the existing standard compact specimen. Tests and analyses were performed to verify that the proposed round compact specimen and associated stress intensity factor K solution are appropriate for a standard plane strain fracture toughness test. The use of the round compact specimen for other fracture tests is described.

  13. Thick Concrete Specimen Construction, Testing, and Preliminary Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hoegh, Kyle [Univ. of Minnesota, Minneapolis, MN (United States); Khazanovich, Lev [Univ. of Minnesota, Minneapolis, MN (United States)

    2015-03-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the various nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations. A preliminary report detailed some of the challenges associated with thick reinforced concrete sections and prioritized conceptual designs of specimens that could be fabricated to represent NPP concrete structures for using in NDE evaluation comparisons. This led to the construction of the concrete specimen presented in this report, which has sufficient reinforcement density and cross-sectional size to represent an NPP containment wall. Details on how a suitably thick concrete specimen was constructed are presented, including the construction materials, final nominal design schematic, as well as formwork and rigging required to safely meet the desired dimensions of the concrete structure. The report also details the type and methods of forming the concrete specimen as well as information on how the rebar and simulated defects were embedded. Details on how the resulting specimen was transported, safely anchored, and marked to allow access for systematic comparative NDE testing of defects in a representative NPP containment wall concrete specimen are also given. Data collection using the MIRA Ultrasonic NDE equipment and

  14. Surveillance dosimetry of operating power plants

    International Nuclear Information System (INIS)

    McElroy, W.N.; Davis, A.I.; Gold, R.

    1981-01-01

    The main focus of the research efforts presently underway is the LWR power reactor surveillance program in which metallurgical test specimens of the reactor PV and dosimetry sensors are placed in three or more surveillance capsules at or near the reactor PV inner wall. They are then irradiated in a temperature and neutron flux-spectrum environment as similar as possible to the PV itself for periods of about 1.5 to 15 effective full-power years (EFPY), with removal of the last capsule at a fluence corresponding to the 30- to 40-year plant end-of-life (EOL) fluence. Because the neutron flux level at the surveillance position is greater than at the vessel, the test is accelerated wit respect to the vessel exposure, allowing early assessment of EOL conditions

  15. Influence of thermal conditioning media on Charpy specimen test temperature

    International Nuclear Information System (INIS)

    Nanstad, R.K.; Swain, R.L.; Berggren, R.G.

    1989-01-01

    The Charpy V-notch (CVN) impact test is used extensively for determining the toughness of structural materials. Research programs in many technologies concerned with structural integrity perform such testing to obtain Charpy energy vs temperature curves. American Society for Testing and Materials Method E 23 includes rather strict requirements regarding determination and control of specimen test temperature. It specifies minimum soaking times dependent on the use of liquids or gases as the medium for thermally conditioning the specimen. The method also requires that impact of the specimen occur within 5 s removal from the conditioning medium. It does not, however, provide guidance regarding choice of conditioning media. This investigation was primarily conducted to investigate the changes in specimen temperature which occur when water is used for thermal conditioning. A standard CVN impact specimen of low-alloy steel was instrumented with surface-mounted and embedded thermocouples. Dependent on the media used, the specimen was heated or cooled to selected temperatures in the range -100 to 100 degree C using cold nitrogen gas, heated air, acetone and dry ice, methanol and dry ice, heated oil, or heated water. After temperature stabilization, the specimen was removed from the conditioning medium while the temperatures were recorded four times per second from all thermocouples using a data acquisition system and a computer. The results show that evaporative cooling causes significant changes in the specimen temperatures when water is used for conditioning. Conditioning in the other media did not result in such significant changes. The results demonstrate that, even within the guidelines of E 23, significant test temperature changes can occur which may substantially affect the Charpy impact test results if water is used for temperature conditioning. 7 refs., 11 figs

  16. Effects of Forgetting Phenomenon on Surveillance Test Interval

    International Nuclear Information System (INIS)

    Lee, Ho-Joong; Jang, Seung-Cheol

    2007-01-01

    Technical Specifications (TS) requirements for nuclear power plants (NPPs) define Surveillance Requirements (SRs) to assure safety during operation. SRs include surveillance test intervals (STIs) and the optimization of the STIs is one of the main issues in risk-informed applications. Surveillance tests are required in NPPs to detect failures in standby equipment to assure their availability in an accident. However, operating experience of the plants suggests that, in addition to the beneficial effects of detecting latent faults, the tests also may have adverse effects on plant operation or equipment; e.g., plant transient caused by the test and wear-out of safety system equipment due to repeated testing. Recent studies have quantitatively evaluated both the beneficial and adverse effects of testing to decide on an acceptable test interval. The purpose of this research is to investigate the effects of forgetting phenomenon on STI. It is a fundamental human characteristic that a person engaged in a repetitive task will improve his performance over time. The learning phenomenon is observed by the decrease in operation time per unit as operators gain experience by performing additional tasks. However, once there is a break of sufficient length, forgetting starts to take place. In surveillance tests, the most common factor to determine the amount of forgetting is the length of STI, where the longer the STI, the greater the amount of forgetting

  17. Audit of Helicobacter pylori Testing in Microbiology Laboratories in England: To Inform Compliance with NICE Guidance and the Feasibility of Routine Antimicrobial Resistance Surveillance

    Directory of Open Access Journals (Sweden)

    Rosalie Allison

    2016-01-01

    Full Text Available Introduction. The National Institute for Health and Clinical Excellence (NICE guidance recommends that dyspeptic patients are tested for Helicobacter pylori using a urea breath test, stool antigen test, or serology. Antibiotic resistance in H. pylori is globally increasing, but treatment in England is rarely guided by susceptibility testing or surveillance. Aims. To determine compliance of microbiology laboratories in England with NICE guidance and whether laboratories perform culture and antibiotic susceptibility testing (AST. Methods. In 2015, 170 accredited English microbiology laboratories were surveyed, by email. Results. 121/170 (71% laboratories responded; 96% provided H. pylori testing (78% on site. 94% provided H. pylori diagnosis using stool antigen; only four provided serology as their noninvasive test; 3/4 of these encouraged urea breath tests in their acute trusts. Only 22/94 (23% of the laboratories performed H. pylori cultures from gastric biopsies on site; 9/22 performed AST, but the vast majority processed less than one specimen/week. Conclusions. Only five laboratories in England do not comply with NICE guidance; these will need the guidance reinforced. National surveillance needs to be implemented; culture-based AST would need to be centralised. Moving forward, detection of resistance in H. pylori from stool specimens using molecular methods (PCR needs to be explored.

  18. Single specimen fracture toughness determination procedure using instrumented impact test

    International Nuclear Information System (INIS)

    Rintamaa, R.

    1993-04-01

    In the study a new single specimen test method and testing facility for evaluating dynamic fracture toughness has been developed. The method is based on the application of a new pendulum type instrumented impact tester equipped with and optical crack mouth opening displacement (COD) extensometer. The fracture toughness measurement technique uses the Double Displacement Ratio (DDR) method, which is based on the assumption that the specimen is deformed as two rigid arms that rotate around an apparent centre of rotation. This apparent moves as the crack grows, and the ratio of COD versus specimen displacement changes. As a consequence the onset ductile crack initiation can be detected on the load-displacement curve. Thus, an energy-based fracture toughness can be calculated. In addition the testing apparatus can use specimens with the Double ligament size as compared with the standard Charpy specimen which makes the impact testing more appropriate from the fracture mechanics point of view. The novel features of the testing facility and the feasibility of the new DDR method has been verified by performing an extensive experimental and analytical study. (99 refs., 91 figs., 27 tabs.)

  19. Biaxial Testing of 2195 Aluminum Lithium Alloy Using Cruciform Specimens

    Science.gov (United States)

    Johnston, W. M.; Pollock, W. D.; Dawicke, D. S.; Wagner, John A. (Technical Monitor)

    2002-01-01

    A cruciform biaxial test specimen was used to test the effect of biaxial load on the yield of aluminum-lithium alloy 2195. Fifteen cruciform specimens were tested from 2 thicknesses of 2195-T8 plate, 0.45 in. and 1.75 in. These results were compared to the results from uniaxial tensile tests of the same alloy, and cruciform biaxial tests of aluminum alloy 2219-T87.

  20. Development of piezoelectric ceramics driven fatigue testing machine for small specimens

    International Nuclear Information System (INIS)

    Saito, S.; Kikuchi, K.; Onishi, Y.; Nishino, T.

    2002-01-01

    A new fatigue testing machine with piezoelectric ceramics actuators was developed and a prototype was manufactured for high-cycle fatigue tests with small specimens. The machine has a simple mechanism and is compact. These features make it easy to set up and to maintain the machine in a hot cell. The excitation of the actuator can be transmitted to the specimen using a lever-type testing jig. More than 100 μm of displacement could be prescribed precisely to the specimen at a frequency of 50 Hz. This was sufficient performance for high-cycle bend fatigue tests on specimens irradiated at the SINQ target in Paul Scherrer Institute. The relationship of a displacement applied to the specimen and the strain of the necking part were obtained by experimental methods and by finite element method (FEM) calculations. Both results showed good agreement. This fact makes it possible to evaluate the strain of irradiated specimens by FEM simulations

  1. Test methodology and technology of fracture toughness for small size specimens

    Energy Technology Data Exchange (ETDEWEB)

    Wakai, E.; Takada, F.; Ishii, T.; Ando, M. [Japan Atomic Energy Agency, Naga-gun, Ibaraki-ken (Japan); Matsukawa, S. [JNE Techno-Research Co., Kanagawa-ken (Japan)

    2007-07-01

    Full text of publication follows: Small specimen test technology (SSTT) is required to investigate mechanical properties in the limited availability of effective irradiation volumes in test reactors and accelerator-based neutron and charged particle sources. The test methodology guideline and the manufacture processes for very small size specimens have not been established, and we would have to formulate it. The technology to control exactly the load and displacement is also required in the test technology under the environment of high dose radiation produced from the specimens. The objective of this study is to examine the test technology and methodology of fracture toughness for very small size specimens. A new bend test machine installed in hot cell has been manufactured to obtain fracture toughness and DBTT (ductile - brittle transition temperature) of reduced-activation ferritic/martensitic steels for small bend specimens of t/2-1/3PCCVN (pre-cracked 1/3 size Charpy V-notch) with 20 mm length and DFMB (deformation and fracture mini bend specimen) with 9 mm length. The new machine can be performed at temperatures from -196 deg. C to 400 deg. C under unloading compliance method. Neutron irradiation was also performed at about 250 deg. C to about 2 dpa in JMTR. After the irradiation, fracture toughness and DBTT were examined by using the machine. Checking of displacement measurement between linear gauge of cross head's displacement and DVRT of the specimen displacement was performed exactly. Conditions of pre-crack due to fatigue in the specimen preparation were also examined and it depended on the shape and size of the specimens. Fracture toughness and DBTT of F82H steel for t/2-1/3PCCVN, DFMB and 0.18DCT specimens before irradiation were examined as a function of temperature. DBTT of smaller size specimens of DFMB was lower than that of larger size specimen of t/2-1/3PCCVN and 0.18DCT. The changes of fracture toughness and DBTT due to irradiation were also

  2. Friction Compensation in the Upsetting of Cylindrical Test Specimens

    DEFF Research Database (Denmark)

    Christiansen, Peter; Martins, P. A. F.; Bay, Niels Oluf

    2016-01-01

    This manuscript presents a combined numerical andexperimental methodology for determining the stress-straincurve of metallic materials from the measurements of forceand displacement obtained in the axial compression of cylindrical test specimens with friction between the specimens and the platens....... The methodology is based on minimizing the errorbetween the average surface pressure obtained from the experimental measurements of the force and displacement and thatobtained from the slab method of analysis of metal plasticity.Three different friction models based on Coulomb friction, the constant friction...... model or combined friction models are utilized .Experimental results obtained from cylindrical and Rastegaev test specimens with different lubricants combined with the experimental determination of friction by means of ring compression tests allows compensating the effect of friction...

  3. Fabrication and testing of prestressed composite rotor blade spar specimens

    Science.gov (United States)

    Gleich, D.

    1974-01-01

    Prestressed composite spar specimens were fabricated and evaluated by crack propagation and ballistic penetration tests. The crack propagation tests on flawed specimens showed that the prestressed composite spar construction significantly suppresses crack growth. Damage from three high velocity 30 caliber projectile hits was confined to three small holes in the ballistic test specimen. No fragmentation or crack propagation was observed indicating good ballistic damage resistance. Rotor attachment approaches and improved structural performance configurations were identified. Design theory was verified by tests. The prestressed composite spar configuration consisted of a compressively prestressed high strength ARDEFORM 301 stainless steel liner overwrapped with pretensioned S-994 fiberglass.

  4. Non-process instrumentation surveillance and test reduction

    International Nuclear Information System (INIS)

    Ferrell, R.; LeDonne, V.; Donat, T.; Thomson, I.; Sarlitto, M.

    1993-12-01

    Analysis of operating experience, instrument failure modes, and degraded instrument performance has led to a reduction in Technical Specification surveillance and test requirements for nuclear power plant process instrumentation. These changes have resulted in lower plant operations and maintenance (O ampersand M) labor costs. This report explores the possibility of realizing similar savings by reducing requirements for non-process instrumentation. The project team reviewed generic Technical Specifications for the four major US nuclear steam supply system (NSSS) vendors (Westinghouse, General Electric, Combustion Engineering, and Babcock ampersand Wilcox) to identify nonprocess instrumentation for which surveillance/test requirements could be reduced. The team surveyed 10 utilities to identify specific non-process instrumentation at their plants for which requirements could be reduced. The team evaluated utility analytic approaches used to justify changes in surveillance/test requirements for process equipment to determine their applicability to non-process instrumentation. The report presents a prioritized list of non-process instrumentation systems suitable for surveillance/test requirements reduction. The top three systems in the list are vibration monitors, leak detection monitors, and chemistry monitors. In general, most non-process instrumentation governed by Technical Specification requirements are candidates for requirements reduction. If statistical requirements are somewhat relaxed, the analytic approaches previously used to reduce requirements for process instrumentation can be applied to non-process instrumentation. The report identifies as viable the technical approaches developed and successfully used by Southern California Edison, Arizona Public Service, and Boston Edison

  5. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens

    Science.gov (United States)

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-01

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified. PMID:29337867

  6. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens.

    Science.gov (United States)

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-16

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified.

  7. Uniaxial compression tests on diesel contaminated frozen silty soil specimens

    International Nuclear Information System (INIS)

    Chenaf, D.; Stampli, N.; Bathurst, R.; Chapuis, R.P.

    1999-01-01

    Results of a uniaxial, unconfined compression test on artificial diesel-contaminated and uncontaminated frozen silty soils are discussed. The testing program involved 59 specimens. The results show that for the same fluid content, diesel contamination reduced the strength of the frozen specimens by increasing the unfrozen water content. For example, in specimens containing 50 per cent diesel oil of the fluid content by weight the maximum strength was reduced by 95 per cent compared to the strength of an uncontaminated specimen. Diesel contamination was also shown to contribute to the slippage between soil particles by acting as a lubricant, thus accelerating the loss of compressive strength.13 refs., 18 figs

  8. Strip specimen tests for pipeline materials and girth welds

    Energy Technology Data Exchange (ETDEWEB)

    Mohr, William C. [Edison Welding Institute (EWI), Columbus, Ohio (United States)

    2009-07-01

    Strip specimen testing of pipeline materials has been widely applied as a method of getting data relevant to the performance of pipelines under axial direction loading. Comparisons of strip specimen against smaller standard tests (round tensile bar, fracture toughness specimens, polished round bars) and against full-scale or large-scale testing will be explored. Data from early-generation pipe welds from the 1920's to the 1940's to the most recent materials for offshore reeled pipe will be used for examples. Strip samples can provide full thickness information to take account of varying material properties or imperfection distribution through the thickness. Strip samples can also accommodate measurement of effects of the original surface finish or weld surface shape. Strip samples have more design flexibility than standard tests, but must be designed to limit stress concentrations and effects of local bending. (author)

  9. Catalogue of test specimens for non-destructive examination

    International Nuclear Information System (INIS)

    1985-05-01

    One of the key elements in assuring the integrity of reactor primary circuits is the availability of trustworthy non-destructive methods for detecting dangerous defects that may be present. Various approaches to making such examinations are being developed, including the use of ultrasonic and radiographic techniques. To demonstrate their capability and reliability, they must be tested on steel specimens reproducing the various types of faults which may arise in real primary circuit vessels and piping. Such specimens are costly to fabricate. It is therefore clearly desirable that existing specimens should be made accessible to as many organisations as possible for testing. This catalogue contains detailed Information on forty-odd deliberately flawed plates, blocks, vessels, etc. which have been produced in OECD countries, along with the name of a contact person to whom inquiries should be directed in each case

  10. Surveillance systems to track progress toward global polio eradication - worldwide, 2012-2013.

    Science.gov (United States)

    Levitt, Alexandra; Diop, Ousmane M; Tangermann, Rudolf H; Paladin, Fem; Kamgang, Jean Baptiste; Burns, Cara C; Chenoweth, Paul J; Goel, Ajay; Wassilak, Steven G F

    2014-04-25

    In 2012, the World Health Assembly of the World Health Organization (WHO) declared completion of polio eradication a programmatic emergency. Polio cases are detected through surveillance of acute flaccid paralysis (AFP) cases and subsequent testing of stool specimens for polioviruses (PVs) at WHO-accredited laboratories within the Global Polio Laboratory Network (GPLN). AFP surveillance is supplemented by environmental surveillance, testing sewage samples from selected sites for PVs. Virologic surveillance, including genomic sequencing to identify isolates by genotype and measure divergence between isolates, guides Global Polio Eradication Initiative (GPEI) activities by confirming the presence of PV, tracking chains of PV transmission, and highlighting gaps in AFP surveillance quality. This report provides AFP surveillance quality indicators at national and subnational levels during 2012-2013 for countries that experienced PV cases during 2009-2013 in the WHO African Region (AFR) and Eastern Mediterranean Region (EMR), the remaining polio-endemic regions. It also summarizes the results of environmental surveillance and reviews indicators assessing the timeliness of reporting of PV isolation and of virus strain characterization globally. Regional-level performance indicators for timely reporting of PV isolation were met in five of six WHO regions in 2012 and 2013. Of 30 AFR and EMR countries that experienced cases of PV (wild poliovirus [WPV], circulating vaccine-derived poliovirus [cVDPV], or both) during 2009-2013, national performance indicator targets for AFP surveillance and collection of adequate specimens were met in 27 (90%) countries in 2012 and 22 (73%) in 2013. In 17 (57%) countries, ≥80% of the population lived in subnational areas meeting both AFP performance indicators in 2012, decreasing to 13 (43%) in 2013. To achieve polio eradication and certify interruption of PV transmission, intensive efforts to strengthen and maintain AFP surveillance are

  11. Extension of the surveillance program at NPP Paks

    International Nuclear Information System (INIS)

    Gillemot, F.

    1992-01-01

    In WWER-440 reactors the surveillance specimens are located in accelerated irradiation positions. After five years all specimens are withdrawn and the operational changes are not monitored. At Paks NPP a new surveillance program extension is started to eliminate of this disadvantage of the original program. (author)

  12. Analysis of mechanical property data obtained from nuclear pressure vessel surveillance capsules

    International Nuclear Information System (INIS)

    Perrin, J.S.

    1977-01-01

    A typical pressure vessel surveillance capsule examination program provides mechanical property data from tensile, Charpy V-notch impact, and, in some cases, fracture mechanics specimens. This data must be analyzed in conjunction with the unirradiated baseline mechanical property data to determine the effect of irradiation on the mechanical properties. In the case of Charpy impact specimens, for example, irradiation typically causes an increase in the transition temperature, and a decrease in the upper shelf energy level. The results of the Charpy impact and other mechanical specimen tests must be evaluated to determine if property changes are occurring in the manner expected when the reactor was put into service. The large amount of data obtained from surveillance capsule examinations in recent years enables one to make fairly good predictions. After the changes in the mechanical properties of specimens from a particular surveillance capsule have been experimentally determined and evaluated, they must be related to the reactor pressure vessel. This requires a knowledge of the neutron fluence of the surveillance capsule, and the ratio of the surveillance capsule fluence to the pressure vessel wall fluence. This ratio is frequently specified by the reactor manufacturer, or can be calculated from a knowledge of the geometry and materials of the reactor components inside the pressure vessel. A knowledge of the exact neutron fluence of the capsule specimens and the capsule to vessel wall neutron fluence ratio is of great importance, since inaccuracies in these numbers cause just as serious a problem as inaccuracies in the mechanical property determinations. A further area causing analysis difficulties is problems encountered in recent capsule programs relating to capsule design, construction, operation, and dismantling. (author)

  13. Is active surveillance a safe alternative in the management of localized prostate cancer? Pathological features of radical prostatectomy specimens in potential candidates for active surveillance

    Directory of Open Access Journals (Sweden)

    Zambrano Norman

    2014-04-01

    Full Text Available Introduction and objectiveActive surveillance (AS has become an accepted alternative for patients with low risk prostate cancer. The purpose of AS is to defer definitive therapy in these patients to avoid treatment-related complications. Our aim was to determine the pathological features of the surgical specimen from potential AS candidates that underwent radical prostatectomy (RP.Materials and MethodsWe retrospectively reviewed a group of patients submitted to RP who met criteria for AS: Gleason score (GS ≤ 3+3 = 6, PSA ≤ 10ng/mL, T1c - T2a, 6 in the RPS (GS 7 n = 49; GS 8 n = 3. Extracapsular extension, seminal vesicle and lymph node involvement was found in 6.1%, 3.1% and 1.2% of the specimens, respectively.ConclusionIn this study a significant proportion of potential candidates for AS showed features of aggressive and/or high-risk tumors in the RPS. Therefore, before considering a patient for an AS protocol, a proper and strict selection must be performed, and informed consent is crucial for these patients.

  14. Methods and devices for small specimen testing at the Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    Jitsukawa, Shiro; Kizaki, Minoru; Umino, Akira; Shiba, Kiyoyuki; Hishinuma, Akimichi

    1993-01-01

    Devices for a punch test on annular notched specimens, small punch (SP) tests, and miniaturized tension tests in hot cells were developed. A micro-manipulator to handle small specimens and an electro-discharge machine (EDM) to extract miniaturized tension specimens and annular notched specimens from transmission electron microscopy (TEM) disks were also fabricated. These devices were designed and made for remote operation in hot cells. Preliminary tests to evaluate the applicability of test methods were carried out. Correlation between SP test results and tensile properties was not strong. Miniaturized tensile results were reasonably similar to the results with larger specimens. The ductile-brittle transition temperature (DBTT) by the punch test on annular notched specimens was higher than that obtained from the SP test. However, materials dependence of the DBTT was different from that measured by standard Charpy V-notch (CVN) tests. This may be due to a specimen size effect

  15. Re-utilization by '' Stud Welding'' of capsules charpy-V belonged to surveillance programs

    International Nuclear Information System (INIS)

    Lapena, J.; Perosanz, F. J.; Gachuz, M.

    1998-01-01

    The perspectives of nuclear plants life extension that are approximating to their end of design life compels to make new surveillance programs. The re-utilization of specimens belonging to surveillance capsules already tested in these new surveillance programs seems be a solution worldwide accepted. The two possible re-utilization processes of this irradiated material are: Subsized specimens and Reconstitution. While the first alternative (Subsized specimens) outlines serious problems for apply the results, the reconstitution eliminates this problem, since the resulting specimens after of the reconstruction procedure would be of the same dimensions that the original. The reconstruction process involves welds, and therefore it has associated the specific problems of this type of joints. Furthermore, by be tried to material irradiated with certain degree of internal damage, that is the variable to evaluate, requires that the heat contribution to the piece not originate local thermal treatments that alter its mechanical qualities. In this work has been followed the evolution by the variables of the weld process and their influence on the quality by the union from metallographic al point of view as well as mechanical for a weld procedure by Stud Welding. The principal objective is to optimize said parameters to assure a good mechanical continuity, without detriment of the microstructural characteristics of the original material. To verify this last have been accomplished with metallographical tests, temperature profile, hardness and will be carried out also Charpy tests. (Author)

  16. Testing machine for fatigue crack kinetic investigation in specimens under bending

    International Nuclear Information System (INIS)

    Panasyuk, V.V.; Ratych, L.V.; Dmytrakh, I.N.

    1978-01-01

    A kinematic diagram of testing mashine for the investigation of fatigue crack kinetics in prismatic specimens, subjected to pure bending is described. Suggested is a technique of choosing an optimum ratio of the parameters of ''the testing machine-specimen'' system, which provide the stabilization of the stress intensity coefficient for a certain region of crack development under hard loading. On the example of the 40KhS and 15Kh2MFA steel specimens the pliability of the machine constructed according to the described diagram and designed for the 30ONxm maximum bending moment. The results obtained can be used in designing of the testing machines for studying pure bending under hard loading and in choosing the sizes of specimens with rectangular cross sections for investigations into the kinetics of the fatigue crack

  17. A test specimen for characterizing the fracture energy of interfaces in composites

    International Nuclear Information System (INIS)

    Shaw, L.; Abbaschian, R.

    1993-01-01

    A sandwich-type chevron-notched specimen, which has a phase angle of loading near zero, is proposed to measure interfacial fracture energy arising mainly from chemical bonding. With the specimen configuration of this kind, the advantages from both sandwich test specimens and chevron-notched specimens can be combined to provide an easy and accurate test for the measurement of interfacial fracture energy. The validity of the specimen has been analyzed in terms of the mechanics of sandwich-type specimens and chevron-notched specimens, and demonstrated using the Al 2 O 3 /Nb bimaterial system. The results show that for a phase angle of loading around -7 degrees the Al 2 O 3 /Nb interface has a fracture energy of 9.3 ± 0.2 J/m 2 . 39 refs

  18. An acceleration test for stress corrosion cracking using humped specimen

    International Nuclear Information System (INIS)

    Kamaya, Masayuki; Fukumura, Takuya; Totsuka, Nobuo

    2003-01-01

    By using the humped specimen, which is processed by the humped die, in the slow strain rate technique (SSRT) test, fracture facet due to stress corrosion cracking (SCC) can be observed in relatively short duration. Although the cold work and concentrated stress and strain caused by the characteristic shape of the specimen accelerate the SCC, to date these acceleration effects have not been examined quantitatively. In the present study, the acceleration effects of the humped specimen were examined through experiments and finite element analyses (FEA). The experiments investigated the SCC of alloy 600 in the primary water environment of a pressurized water reactor. SSRT tests were conducted using two kinds of humped specimen: one was annealed after hump processing in order to eliminate the cold work, and the other was hump processed after the annealing treatment. The work ratio caused by the hump processing and stress/strain conditions during SSRT test were evaluated by FEA. It was found that maximum work ratio of 30% is introduced by the hump processing and that the distribution of the work ratio is not uniform. Furthermore, the work ratio is influenced by the friction between the specimen and dies as well as by the shape of dies. It was revealed that not only the cold work but also the concentrated stress and strain during SSRT test accelerate the crack initiation and growth of the SCC. (author)

  19. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    International Nuclear Information System (INIS)

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-01-01

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  20. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-09-15

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  1. Surveillance of transmitted HIV drug resistance using matched plasma and dried blood spot specimens from voluntary counseling and testing sites in Ho Chi Minh City, Vietnam, 2007-2008.

    Science.gov (United States)

    Duc, Nguyen Bui; Hien, Bui Thu; Wagar, Nick; Tram, Tran Hong; Giang, Le Truong; Yang, Chunfu; Wolfe, Mitchell I; Hien, Nguyen Tran; Tuan, Nguyen Anh

    2012-05-01

    During 2007-2008, surveillance of transmitted human immunodeficiency virus (HIV) drug resistance (TDR) was performed following World Health Organization guidance among clients with newly diagnosed HIV infection attending voluntary counseling and testing (VCT) sites in Ho Chi Minh City (HCMC), Vietnam. Moderate (5%-15%) TDR to nonnucleoside reverse-transcriptase inhibitors (NNRTIs) was observed among VCT clients aged 18-21 years. Follow-up surveillance of TDR in HCMC and other geographic regions of Vietnam is warranted. Data generated will guide the national HIV drug resistance surveillance strategy and support selection of current and future first-line antiretroviral therapy and HIV prevention programs.

  2. Evaluation of Specimen Geometric Effect for Laser Flash Thermal Diffusivity Test

    International Nuclear Information System (INIS)

    Park, Dae Gyu; Kim, Hee Moon; Song, Woong Sub; Baik, Seung Je; Ryu, Woo Seok; Ahn, Sang Bok; Joo, Young Sun

    2012-01-01

    KAERI(Korea Atomic Energy Research Institute) is developing a new type of nuclear reactor, the so called 'SMART' (System Integrated Modular Advanced Reactor) reactor. Alloy 690 was selected as the candidate material for the heat exchanger tube of of SMART's steam generator. The SMART R and D is now facing the stage of engineering verification and standard design approval for application of DEMO reactors. Therefore, the material performance under the relevant environment needs to be evaluated. The one of the important material performance issues is thermal conductivity, which the engineering database is necessary for the steam generator design. However, the neutron post irradiation characteristics of alloy 690 are little known. As a result, a PIE (Post Irradiation Examination) of the thermal properties have been plan for a 4 times, so called base line test, 1 st irradiation test, 2 nd and 3 rd irradiation test. But there is some constraint to perform thermal diffusivity test owing to test specimen. Originally thermal diffusivity test are planed using disk shape with 9 mm diameter and 1 mm thick specimen. Due to mismatch of neutron irradiation schedule, thermal diffusivity will be tested by different shape and size specimens at 1 st irradiation test. Therefore, verification of geometric and size effect are necessary for test specimen in order to achieve accurate test results

  3. Testing of irradiated and annealed 15H2MFA materials

    International Nuclear Information System (INIS)

    Gillemot, F.; Uri, G.

    1994-01-01

    A set of surveillance samples made from 15H2MFA material has been studied in the laboratory of AEKI. Miniature notched tensile specimens were cut from some remnants of irradiated and broke surveillance charpy remnants. The Absorbed Specific Fracture Energy (ASFE) was measured on the specimens. A cutting machine and testing technique were elaborated for the measurements. The second part of the Charpy remnants was annealed at 460 deg. C and 490 deg. C for 6-8 hours. The specimens were tested similarity and the results were compared. (author). 5 refs, 9 figs

  4. A new shape specimens determined the J1c value of nuclear pressure vessel steel

    International Nuclear Information System (INIS)

    Xu, W.Q.

    1989-01-01

    The J integral has two basic definitions, a two-dimensional energy line integral definition and an energy rate definition. The line integral definition cannot be used for this experimental determination. The energy rate definition can be used but the procedure is somewhat laborious. Methods were developed for more easily determining J by approximation formulas. The first of these were where J could be estimated with reasonable accuracy for a deeply cracked bend-type specimen. This method is slightly inaccurate. This paper is concerned with a new shape specimen. It is called the W-shape specimen. The W-shape specimens are smaller volume than the compact specimens. It is convenient to operate the W-shape specimens in hot cell. It can be put into surveillance capsules and can also do specimen irradiation in engineering test reactor

  5. The study of the irradiation-induced embrittlement of reactor pressure vessels. Analysis of surveillance test specimens of a commercial nuclear reactor pressure vessel studied by three-dimensional atom probe and positron annihilation

    International Nuclear Information System (INIS)

    Nagai, Yasuyoshi; Toyama, Takeshi; Hasegawa, Masayuki

    2007-01-01

    The study of embrittlement of nuclear power reactor pressure vessels (RPVs) is of critical importance for the safety assessment in the nuclear industry. Some origins of embrittlement are attributed to fine Cu precipitates, matrix defects, grain boundary segregation of P and late blooming phase. This review article described nanostructural observation by three-dimensional atom probe (3DAP) and positron annihilation spectroscopy (PAS). The density and sizes of Cu-rich nanoprecipitates and grain boundary segregation are sensitively detected by 3DAP, and vacancies are probed by PAS. Element analysis around vacancies and fine microstructural Cu precipitates not containing vacancies are successfully observed by a coincidence doppler broadening method. The nanostructural evolution of irradiation-induced Cu-rich nanoprecipitates (CRNPs) and vacancy clusters in surveillance test specimens of commercial nuclear reactor pressure vessel steel welds of Doel-2 in Belgium were revealed by combining 3DAP and PAS. In both medium (0.13 wt%) and high (0.30 wt%) Cu welds, the CRNPs were found to form readily at the very beginning of the reactor lifetime. On the other hand, small vacancy clusters start appearing after the initial Cu precipitates and accumulate steadily with increasing neutron dose. The CRNPs were also observed at very low dose rate of neutrons in the test specimen of Calder Hall Reactor of Japan Atomic Power Company. The significant enhancement of these Cu precipitates results in the embrittlement in practical RPVs. At very high dose of 2.2x10 18 n/cm 2 by JMTR, the Cu precipitates were scarcely observed, and the irradiation-induced embrittlement was primarily caused from vacancy-impurity complexes and dislocation loops. (author)

  6. The technology development for surveillance test of RPV materials 2

    International Nuclear Information System (INIS)

    Chang, Kee Ok; Lee, Sam Lai; Kim, Byoung Chul; Choi, Sun Pil; Choi, Kwen Jai

    1998-12-01

    Irradiation-induced changes in mechanical properties and magnetic parameters were measured and compared to explore possible correlations for Mn-Mo-Ni low alloy steel surveillance specimens which were irradiated to a neutron fluence of 2.4 x 10 1 9n/cm 2 (E≥1.0 MeV) in a typical pressurized water reactor environment at about 288 deg C. For mechanical property parameters, microvickers hardness, tensile and Charpy impact test were performed and Barkhausen Noise(BN) amplitude, coercivity, maximum induction were measured for magnetic parameters, respectively. Results of mechanical property measurements showed an increase in yield and tensil strength, microvickers hardness 41J indexed RT NDT and a decrease in upper shelf energy irrespective of base and weld metals. In the case of magnetic measurements, it is found that magnetic remanence, BN amplitude, BN energy have dropped significantly but coercivity has increased rapidly after irradiation. For isothermally heat treated condition of irradiated specimen, BN energy has increased while Vickers microhardness has decreased. Results of BNE and Vickers microhardness are reversed to the results on irradiated condition. All these consistent changes in magnetic parameter and Vickers microhardness measurement, which are thought to be resulted from the interaction between irradiation-induced defects and dislocation, and magnetic domain, respectively, show a possibility that magnetic measurement may be used to the evaluation of material degradation and recovery due to neutron irradiation and heat treatment, respectively, if a relevant large database is prepared. (author). 49 refs., 7 tabs., 23 figs

  7. Development of technology on the material surveillance of CANDU pressure tubes

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Kye Hoh; Han, Jung Hoh; Lee, Duk Hyun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-05-01

    Material degradation of pressure tubes, which are the most important components in CANDU fuel channel, can only be evaluated by removing and examining them(material surveillance). This study aimed at establishment of overall evaluation technology including the evaluation of the material degradation for the integrity of pressure tubes of Wolsung units. Material tests for pressure tubes were performed as follows; (1) Evaluation on life limiting factors of pressure tubes (2) Review on leak-before-break and integrity maintenance technology of pressure tubes (3) Survey on selection criteria for tubes to be inspected and on related regulations for material surveillance (4) Analysis of material surveillance test procedure (5) Basic examinations of Wolsung unit 1 pressure tube material(TEM, texture, chemical component etc) (6) Manufacture of test equipments and test (DHCV, hydriding, grip and tensile specimen etc). 23 figs, 6 tabs, 59 refs. (Author).

  8. Development of technology on the material surveillance of CANDU pressure tubes

    International Nuclear Information System (INIS)

    Noh, Kye Hoh; Han, Jung Hoh; Lee, Duk Hyun

    1995-05-01

    Material degradation of pressure tubes, which are the most important components in CANDU fuel channel, can only be evaluated by removing and examining them(material surveillance). This study aimed at establishment of overall evaluation technology including the evaluation of the material degradation for the integrity of pressure tubes of Wolsung units. Material tests for pressure tubes were performed as follows; (1) Evaluation on life limiting factors of pressure tubes (2) Review on leak-before-break and integrity maintenance technology of pressure tubes (3) Survey on selection criteria for tubes to be inspected and on related regulations for material surveillance (4) Analysis of material surveillance test procedure (5) Basic examinations of Wolsung unit 1 pressure tube material(TEM, texture, chemical component etc) (6) Manufacture of test equipments and test (DHCV, hydriding, grip and tensile specimen etc). 23 figs, 6 tabs, 59 refs. (Author)

  9. Analyses and results from standard surveillance programmes of WWER 440/V-213C reactor pressure vessels

    Energy Technology Data Exchange (ETDEWEB)

    Falcnik, M; Brumovsky, M; Pav, T [Czech Nuclear Society, Prague (Czech Republic)

    1994-12-31

    In Czech and Slovak republics, six units of WWER 440/C type reactors are monitored by surveillance specimens programmes; the specimens are determined for static tensile testing, impact notch toughness testing and fracture toughness evaluation. Results of mechanical properties of these specimens after irradiation in intervals between 1 and 5 years of operation, are summarized and discussed with respect to the effect of individual heats and welded joints, radiation embrittlement, and annealing recovery. (authors). 3 refs., 11 figs., 2 tabs.

  10. Surveillance specimen programmes for WWER reactor vessels in the Czech Republic

    International Nuclear Information System (INIS)

    Brynda, J.; Hogel, J.; Brumovsky, M.

    2003-01-01

    The present state of materials degradation in WWER reactor pressure vessels manufactured in the Czech Republic is highlighted. The standard surveillance program for WWER-440/V-213 type reactors is described and its deficiencies together with the main results obtained are discussed. A new supplementary surveillance program meeting all requirements for PWR type reactors has been developed and launched. An entirely new design was chosen for the surveillance programme for WWER-1000/V-320 type reactor pressure vessels. Materials selection, container design and location as well as the withdrawal plan connected with ex-vessel fluence monitoring are described

  11. The relaxation of ESFAS/RPS surveillance test requirements

    International Nuclear Information System (INIS)

    Hah, Yung Joon; Koo, Jung Eui; Choi, Hae Yoon

    1994-01-01

    The surveillance test requirement of ESFAS/RPS is reviewed for 950 MWe class westinghouse reactor (YGN unit 1 and 2, Kori unit 3 and 4). The current requirements of frequent test and maintenance in the tech. spec. can lead to human errors, jeopardizing safety of the plant, and reduction in the availability of the plant. Meanwhile, the ESFAS designs do not provide for complete online testing capabilities for their protection systems. Therefore, ESFAS slave relays cannot be tested during plant operation as actuation of associated equipment could result in unwanted plant transient or trip conditions. In this study, westinghouse's PSA results, NRC recommendation and NRC approval status for specific U.S. nuclear power plant have been reviewed and evaluated. Since YGN 1 and 2 and Kori 3 and 4 are essentially the same plant as the operating westinghouse plant in the U.S., it is expected that YGN 1 and 2 and Kori 3 and 4 will be justified for having ESFAS/RPS surveillance test requirements relaxation program. Finally the extension of surveillance testing intervals and allowed outage times for test and maintenance will be verified by PSA program for YGN 1 and 2 and Kori 3 and 4. Various findings during the project can be used in the possible future revision of current technical specification with further refinements through the PSA program for YGN 1 and 2 and Kori 3 and 4. (Author) 10 refs., 8 figs., 24 tabs

  12. The relaxation of ESFAS/RPS surveillance test requirements

    Energy Technology Data Exchange (ETDEWEB)

    Hah, Yung Joon; Koo, Jung Eui; Choi, Hae Yoon [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-01-01

    The surveillance test requirement of ESFAS/RPS is reviewed for 950 MWe class westinghouse reactor (YGN unit 1 and 2, Kori unit 3 and 4). The current requirements of frequent test and maintenance in the tech. spec. can lead to human errors, jeopardizing safety of the plant, and reduction in the availability of the plant. Meanwhile, the ESFAS designs do not provide for complete online testing capabilities for their protection systems. Therefore, ESFAS slave relays cannot be tested during plant operation as actuation of associated equipment could result in unwanted plant transient or trip conditions. In this study, westinghouse`s PSA results, NRC recommendation and NRC approval status for specific U.S. nuclear power plant have been reviewed and evaluated. Since YGN 1 and 2 and Kori 3 and 4 are essentially the same plant as the operating westinghouse plant in the U.S., it is expected that YGN 1 and 2 and Kori 3 and 4 will be justified for having ESFAS/RPS surveillance test requirements relaxation program. Finally the extension of surveillance testing intervals and allowed outage times for test and maintenance will be verified by PSA program for YGN 1 and 2 and Kori 3 and 4. Various findings during the project can be used in the possible future revision of current technical specification with further refinements through the PSA program for YGN 1 and 2 and Kori 3 and 4. (Author) 10 refs., 8 figs., 24 tabs.

  13. Optimization of tensile method and specimen geometry in modified ring tensile test

    International Nuclear Information System (INIS)

    Kitano, Koji; Fuketa, Toyoshi; Sasajima, Hideo; Uetsuka, Hiroshi

    2001-03-01

    Several techniques in ring tensile test are proposed in order to evaluate mechanical properties of cladding under hoop loading condition caused by pellet/cladding mechanical interaction (PCMI). In the modified techniques, variety of tensile methods and specimen geometry are being proposed in order to limit deformation within the gauge section. However, the tensile method and the specimen geometry were not determined in the modified techniques. In the present study, we have investigated the tensile method and the specimen geometry through finite element method (FEM) analysis of specimen deformation and tensile test on specimens with various gauge section geometries. In using two-piece tensile tooling, the mechanical properties under hoop loading condition can be correctly evaluated when deformation part (gauge section) is put on the top of a half-mandrel, and friction between the specimen and the half-mandrel is reduced with Teflon tape. In addition, we have shown the optimum specimen geometry for PWR 17 by 17 type cladding. (author)

  14. 46 CFR 54.05-5 - Toughness test specimens.

    Science.gov (United States)

    2010-10-01

    ... shown in Figure 4 of the specification. Special attention is drawn to the fact that the Charpy Keyhole....090-inch. In preparing weld specimens for dropweight testing, weld reinforcement shall be ground flush...

  15. Twitter Influenza Surveillance: Quantifying Seasonal Misdiagnosis Patterns and their Impact on Surveillance Estimates.

    Science.gov (United States)

    Mowery, Jared

    2016-01-01

    Influenza (flu) surveillance using Twitter data can potentially save lives and increase efficiency by providing governments and healthcare organizations with greater situational awareness. However, research is needed to determine the impact of Twitter users' misdiagnoses on surveillance estimates. This study establishes the importance of Twitter users' misdiagnoses by showing that Twitter flu surveillance in the United States failed during the 2011-2012 flu season, estimates the extent of misdiagnoses, and tests several methods for reducing the adverse effects of misdiagnoses. Metrics representing flu prevalence, seasonal misdiagnosis patterns, diagnosis uncertainty, flu symptoms, and noise were produced using Twitter data in conjunction with OpenSextant for geo-inferencing, and a maximum entropy classifier for identifying tweets related to illness. These metrics were tested for correlations with World Health Organization (WHO) positive specimen counts of flu from 2011 to 2014. Twitter flu surveillance erroneously indicated a typical flu season during 2011-2012, even though the flu season peaked three months late, and erroneously indicated plateaus of flu tweets before the 2012-2013 and 2013-2014 flu seasons. Enhancements based on estimates of misdiagnoses removed the erroneous plateaus and increased the Pearson correlation coefficients by .04 and .23, but failed to correct the 2011-2012 flu season estimate. A rough estimate indicates that approximately 40% of flu tweets reflected misdiagnoses. Further research into factors affecting Twitter users' misdiagnoses, in conjunction with data from additional atypical flu seasons, is needed to enable Twitter flu surveillance systems to produce reliable estimates during atypical flu seasons.

  16. Repeat confirmatory testing for persons with discordant whole blood and oral fluid rapid HIV test results: findings from post marketing surveillance.

    Science.gov (United States)

    Wesolowski, Laura G; Mackellar, Duncan A; Ethridge, Steven F; Zhu, Julia H; Owen, S Michele; Sullivan, Patrick S

    2008-02-06

    Reactive oral fluid and whole blood rapid HIV tests must be followed with a confirmatory test (Western blot (WB), immunofluorescent assay (IFA) or approved nucleic acid amplification test (NAAT)). When the confirmatory result is negative or indeterminate (i.e. discordant with rapid result), repeat confirmatory testing should be conducted using a follow-up specimen. Previous reports have not described whether repeat testing adequately resolves the HIV-infection status of persons with discordant results. Post-marketing surveillance was conducted in 368 testing sites affiliated with 14 state and 2 city health departments from August 11, 2004 to June 30, 2005 and one health department through December 31, 2005. For persons with discordant results, data were collected on demographics, risk behaviors, HIV test results and specimen types. Persons with repeat confirmatory results were classified as HIV-infected or uninfected. Regression models were created to assess risk factors for not having repeat testing. Of 167,371 rapid tests conducted, 2589 (1.6%) were reactive: of these, 2417 (93%) had positive WB/IFA, 172 (7%) had negative or indeterminate WB/IFA. Of 89/172 (52%) persons with a repeat confirmatory test: 17 (19%) were HIV-infected, including 3 with indeterminate WB and positive NAAT; 72 (81%) were uninfected, including 12 with repeat indeterminate WB. Factors associated with HIV-infection included having an initial indeterminate WB/IFA (vs. negative) (ptest [adjusted OR 2.6, 95% CI (1.3, 4.9)]. Though only half of persons with discordant results had repeat confirmatory testing, of those who did, nearly one in five were HIV-infected. These findings underscore the need for rapid HIV testing programs to increase repeat confirmatory testing for persons with discordant results. Because of the lower sensitivity of oral fluid WBs, confirmatory testing following a reactive rapid test should be conducted using serum or plasma, when possible.

  17. Laboratory-based respiratory virus surveillance pilot project on select cruise ships in Alaska, 2013-15.

    Science.gov (United States)

    Rogers, Kimberly B; Roohi, Shahrokh; Uyeki, Timothy M; Montgomery, David; Parker, Jayme; Fowler, Nisha H; Xu, Xiyan; Ingram, Deandra J; Fearey, Donna; Williams, Steve M; Tarling, Grant; Brown, Clive M; Cohen, Nicole J

    2017-09-01

    Influenza outbreaks can occur among passengers and crews during the Alaska summertime cruise season. Ill travellers represent a potential source for introduction of novel or antigenically drifted influenza virus strains to the United States. From May to September 2013-2015, the Alaska Division of Public Health, the Centers for Disease Control and Prevention (CDC), and two cruise lines implemented a laboratory-based public health surveillance project to detect influenza and other respiratory viruses among ill crew members and passengers on select cruise ships in Alaska. Cruise ship medical staff collected 2-3 nasopharyngeal swab specimens per week from passengers and crew members presenting to the ship infirmary with acute respiratory illness (ARI). Specimens were tested for respiratory viruses at the Alaska State Virology Laboratory (ASVL); a subset of specimens positive for influenza virus were sent to CDC for further antigenic characterization. Of 410 nasopharyngeal specimens, 83% tested positive for at least one respiratory virus; 71% tested positive for influenza A or B virus. Antigenic characterization of pilot project specimens identified strains matching predominant circulating seasonal influenza virus strains, which were included in the northern or southern hemisphere influenza vaccines during those years. Results were relatively consistent across age groups, recent travel history, and influenza vaccination status. Onset dates of illness relative to date of boarding differed between northbound (occurring later in the voyage) and southbound (occurring within the first days of the voyage) cruises. The high yield of positive results indicated that influenza was common among passengers and crews sampled with ARI. This finding reinforces the need to bolster influenza prevention and control activities on cruise ships. Laboratory-based influenza surveillance on cruise ships may augment inland influenza surveillance and inform control activities. However, these

  18. Test of large-scale specimens and models as applied to NPP equipment materials

    International Nuclear Information System (INIS)

    Timofeev, B.T.; Karzov, G.P.

    1993-01-01

    The paper presents the test results on low-cycle fatigue, crack growth rate and fracture toughness of large-scale specimens and structures, manufactured from steel, widely applied in power engineering industry and used for the production of NPP equipment with VVER-440 and VVER-1000 reactors. The obtained results are compared with available test results of standard specimens and calculation relations, accepted in open-quotes Calculation Norms on Strength.close quotes At the fatigue crack initiation stage the experiments were performed on large-scale specimens of various geometry and configuration, which permitted to define 15X2MFA steel fracture initiation resistance by elastic-plastic deformation of large material volume by homogeneous and inhomogeneous state. Besides the above mentioned specimen tests in the regime of low-cycle loading, the test of models with nozzles were performed and a good correlation of the results on fatigue crack initiation criterium was obtained both with calculated data and standard low-cycle fatigue tests. It was noted that on the Paris part of the fatigue fracture diagram a specimen thickness increase does not influence fatigue crack growth resistance by tests in air both at 20 and 350 degrees C. The estimation of the comparability of the results, obtained on specimens and models was also carried out for this stage of fracture. At the stage of unstable crack growth by static loading the experiments were conducted on specimens of various thickness for 15X2MFA and 15X2NMFA steels and their welded joints, produced by submerged arc welding, in as-produced state (the beginning of service) and after embrittling heat treatment, simulating neutron fluence attack (the end of service). The obtained results give evidence of the possibility of the reliable prediction of structure elements brittle fracture using fracture toughness test results on relatively small standard specimens. 35 refs., 23 figs

  19. Fracture toughness evaluation of Eurofer'97 by testing small specimens

    International Nuclear Information System (INIS)

    Serrano, M.; Fernandez, P.; Lapena, J.

    2006-01-01

    The Eurofer'97 is the structural reference material that will be tested in the ITER modules. Its metallurgical properties have been well characterized during the last years. However, more investigations related with the fracture toughness of this material are necessary because this property is one of the most important to design structural components and to study their integrity assessment. In the case of structural materials for fusion reactor the small specimen technology (SSTT) are being actively developed to investigate the fracture toughness among other mechanical properties. The use of small specimens is due to the small available irradiation volume of IFMIF and also due to the high fluence expected in the fusion reactor. The aim of this paper is to determine the fracture toughness of the Eurofer'97 steel by testing small specimens of different geometry in the ductile to brittle transition region, with the application of the Master Curve methodology, and to evaluate this method to assess the decrease in fracture toughness due to neutron irradiation. The tests and data analysis have been performed following the Master Curve approach included in the ASTM Standard E1921-05. Specimen size effect and comparison of the fracture toughness results with data available in the literature are also considered. (author)

  20. Fracture toughness evaluation using small specimens for assuring structural integrity of PRV's

    International Nuclear Information System (INIS)

    Lee, Bong Sang; Hong, J. H.; Chi, S. H.; Kim, J. H.; Yang, W. J.

    1999-08-01

    This report summarizes the results obtained from the three year contribution of KAERI to the IAEA-CRP on ''Assuring Structural Integrity of Reactor Pressure Vessels''. The mandatory part of this programme is to perform fracture toughness K jc tests using pre-cracked Charpy specimens on the IAEA reference material JRQ (ASTM A533-B1 steel). The results will be used to validate the small specimens for surveillance tests. In this report, three different heats of reactor pressure vessel materials are characterized by the ASTM E 1921-97 s tandard test method for determination of reference temperature, T o , for ferritic steels in the transition range . The materials are the IAEA reference plate (JRQ), a Japanese forging (JEL), and a Korean forging (KFY5). 6 refs., 7 tabs., 20 figs

  1. Elastic-plastic analysis of fracture mechanics test specimens. Part 2

    International Nuclear Information System (INIS)

    Talja, H.; Wallin, K.

    1984-12-01

    This is second part of the report of the research program 'Comparisons between computational and experimental elastic-plastic results' started at the Technical Research Centre of Finland in 1981. The first part of the research program was reported earlier and contained a two dimensional linear elastic finite element analysis of four specimen geometries (CT, RCT, ASTM-3P and Charpy-V) and testing and elastic-plastic analysis of the specimen (EGF71; 1TCT, material A 542). In this report the second part of the program containing the testing and 2-D elastic-plastic analyses of five specimens is described. The four specimen geometries mentioned above and two different materials (stainless steel AISI 304 and ferrite pressure vessel steel A533B) are considered. The following comparisons are presented in the report: load vs. load displacement curves, J-integral, crack opening displacement (COD), J vs. COD and the size of the plastic zone. The agreement between the computational and experimental results is quite good. Complete agreement can be achieved only with 3-dimensional calculation models. (author)

  2. Tensile tests and metallography of brazed AISI 316L specimens after irradiation

    International Nuclear Information System (INIS)

    Groot, P.; Franconi, E.

    1994-01-01

    Stainless steel type 316L tensile specimens were vacuum brazed with three kinds of alloys: BNi-5, BNi-6, and BNi-7. The specimens were irradiated up to 0.7 dpa at 353 K in the High Flux Reactor at JRC Petten, the Netherlands. Tensile tests were performed at a constant displacement rate of 10 -3 s -1 at room temperature in the ECN hot cell facility. BNi-5 brazed specimens showed ductile behaviour. Necking and fractures were localized in the plate material. BNi-6 and BNi-7 brazed specimens failed brittle in the brazed zone. This was preceded by uniform deformation of the plate material. Tensile test results of irradiated specimens showed higher stresses due to radiation hardening and a reduction of the elongation of the plate material compared to the reference. SEM examination of the irradiated BNi-6 and BNi-7 fracture surfaces showed nonmetallic phases. These phases were not found in the reference specimens. ((orig.))

  3. LWR surveillance dosimetry improvement program: PSF metallurgical blind test results

    International Nuclear Information System (INIS)

    Kam, F.B.K.; Stallmann, F.W.; Guthrie, G.; McElroy, W.N.

    1985-01-01

    The ORR-PSF benchmark experiment was designed to simulate the surveillance capsule-pressure vessel configuration in power reactors and to test the validity of procedures which determine the radiation damage in the vessel from test results in the surveillance capsule. The PSF metallurgical blind test was initiated to give participants an opportunity to test their current embrittlement prediction methodologies. Experimental results were withheld from the participants except for the type of information which is normally contained in surveillance reports. Preliminary analysis of the PSF metallurgical blind test results shows that: (1) current prediction methodologies, as used by the PSF Blind Test participants, are adequate, falling within +- 20 0 C of the measured values for Δ NDT. None of the different methods is clearly superior; (2) the proposed revision of Reg. Guide 1.99 (Rev. 2) gives a better representation of the fluence and chemistry dependency of Δ NDT than the current version (Rev. 1); and (3) fluence rate effects can be seen but not quantified. Fluence spectral effects are too small to be detectable in this experiment. (orig.)

  4. qPCR-High resolution melt analysis for drug susceptibility testing of Mycobacterium leprae directly from clinical specimens of leprosy patients.

    Science.gov (United States)

    Araujo, Sergio; Goulart, Luiz Ricardo; Truman, Richard W; Goulart, Isabela Maria B; Vissa, Varalakshmi; Li, Wei; Matsuoka, Masanori; Suffys, Philip; Fontes, Amanda B; Rosa, Patricia S; Scollard, David M; Williams, Diana L

    2017-06-01

    identify mixed infections of susceptible and resistant M. leprae. However, to avoid false positives we recommend that clinical specimens be tested for the presence of the M. leprae using the qPCR-RLEP assay prior to being tested in the qPCR-HRM DST and that all specimens demonstrating drug resistant profiles in this assay be subjected to DNA sequencing. Taken together these results further demonstrate the utility of qPCR-HRM DST as an inexpensive screening tool for large-scale drug resistance surveillance in leprosy.

  5. Fabrication and loading of long-term stress corrosion cracking surveillance specimens for the Dresden 1 decontamination program

    International Nuclear Information System (INIS)

    Walker, W.L.

    1979-10-01

    Stress-corrosion cracking test specimens were prepared for Dow Nuclear Services for insertion in the Dresden 1 reactor during the chemical decontamination of the primary system, and for subsequent exposure under operating conditions when the station returns to service. The specimens consist of pressurized tubes fabricated from Type-304 and -304L stainless steel, Inconel 600, Incoloy 800, and Zircaloy 2. In addition, constant radius bent-beam specimens of 3/4 hard Type-410 stainless steel were also included. All specimens were stressed to, or slightly above, their respective 0.2% offset yield strengths at the temperatures of interest

  6. Optimization of Allowed Outage Time and Surveillance Test Intervals

    Energy Technology Data Exchange (ETDEWEB)

    Al-Dheeb, Mujahed; Kang, Sunkoo; Kim, Jonghyun [KEPCO international nuclear graduate school, Ulsan (Korea, Republic of)

    2015-10-15

    The primary purpose of surveillance testing is to assure that the components of standby safety systems will be operable when they are needed in an accident. By testing these components, failures can be detected that may have occurred since the last test or the time when the equipment was last known to be operational. The probability a system or system component performs a specified function or mission under given conditions at a prescribed time is called availability (A). Unavailability (U) as a risk measure is just the complementary probability to A(t). The increase of U means the risk is increased as well. D and T have an important impact on components, or systems, unavailability. The extension of D impacts the maintenance duration distributions for at-power operations, making them longer. This, in turn, increases the unavailability due to maintenance in the systems analysis. As for T, overly-frequent surveillances can result in high system unavailability. This is because the system may be taken out of service often due to the surveillance itself and due to the repair of test-caused failures of the component. The test-caused failures include those incurred by wear and tear of the component due to the surveillances. On the other hand, as the surveillance interval increases, the component's unavailability will grow because of increased occurrences of time-dependent random failures. In that situation, the component cannot be relied upon, and accordingly the system unavailability will increase. Thus, there should be an optimal component surveillance interval in terms of the corresponding system availability. This paper aims at finding the optimal T and D which result in minimum unavailability which in turn reduces the risk. Applying the methodology in section 2 to find the values of optimal T and D for two components, i.e., safety injection pump (SIP) and turbine driven aux feedwater pump (TDAFP). Section 4 is addressing interaction between D and T. In general

  7. Optimization of Allowed Outage Time and Surveillance Test Intervals

    International Nuclear Information System (INIS)

    Al-Dheeb, Mujahed; Kang, Sunkoo; Kim, Jonghyun

    2015-01-01

    The primary purpose of surveillance testing is to assure that the components of standby safety systems will be operable when they are needed in an accident. By testing these components, failures can be detected that may have occurred since the last test or the time when the equipment was last known to be operational. The probability a system or system component performs a specified function or mission under given conditions at a prescribed time is called availability (A). Unavailability (U) as a risk measure is just the complementary probability to A(t). The increase of U means the risk is increased as well. D and T have an important impact on components, or systems, unavailability. The extension of D impacts the maintenance duration distributions for at-power operations, making them longer. This, in turn, increases the unavailability due to maintenance in the systems analysis. As for T, overly-frequent surveillances can result in high system unavailability. This is because the system may be taken out of service often due to the surveillance itself and due to the repair of test-caused failures of the component. The test-caused failures include those incurred by wear and tear of the component due to the surveillances. On the other hand, as the surveillance interval increases, the component's unavailability will grow because of increased occurrences of time-dependent random failures. In that situation, the component cannot be relied upon, and accordingly the system unavailability will increase. Thus, there should be an optimal component surveillance interval in terms of the corresponding system availability. This paper aims at finding the optimal T and D which result in minimum unavailability which in turn reduces the risk. Applying the methodology in section 2 to find the values of optimal T and D for two components, i.e., safety injection pump (SIP) and turbine driven aux feedwater pump (TDAFP). Section 4 is addressing interaction between D and T. In general

  8. 2003 Nevada Test Site Annual Illness and Injury Surveillance Report

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Office of Health, Safety and Security, Office of Illness and Injury Prevention Programs

    2007-05-23

    Annual Illness and Injury Surveillance Program report for 2003 for the Nevada Test Site. The U.S. Department of Energy’s (DOE) commitment to assuring the health and safety of its workers includes the conduct of epidemiologic surveillance activities that provide an early warning system for health problems among workers. The Illness and Injury Surveillance Program monitors illnesses and health conditions that result in an absence of workdays, occupational injuries and illnesses, and disabilities and deaths among current workers.

  9. Assessment of plastic flow and fracture properties with small specimens test techniques for IFMIF-designed specimens

    International Nuclear Information System (INIS)

    Spaetig, P.; Campitelli, E.N.; Bonade, R.; Baluc, N.

    2005-01-01

    The primary mission of the International Fusion Material Irradiation Facility (IFMIF) is to generate a material database to be used for the design of various components, for the licensing and for the assessment of the safe operation of a demonstration fusion reactor. IFMIF is an accelerator-based high-energy neutron source whose irradiation volume is quite limited (0.5 l for the high fluence volume). This requires the use of small specimens to measure the irradiation-induced changes on the physical and mechanical properties of materials. In this paper, we developed finite element models to better analyze the results obtained with two different small specimen test techniques applied to the tempered martensitic steel F82H-mod. First, one model was used to reconstruct the load-deflection curves of small ball punch tests, which are usually used to extract standard tensile parameters. It was shown that a reasonable assessment of the overall plastic flow can be done with small ball punch tests. Second, we investigated the stress field sensitivity at a crack tip to the constitutive behavior, for a crack modeled in plane strain, small-scale yielding and fracture mode I conditions. Based upon a local criterion for cleavage, that appears to be the basis to account for the size and geometry effects on fracture toughness, we showed that the details of the constitutive properties play a key role in modeling the irradiation-induced fracture toughness changes. Consequently, we suggest that much more attention and efforts have to be paid in investigating the post-yield behavior of the irradiated specimens and, in order to reach this goal, we recommend the use of not only tensile specimens but also that of compression ones in the IFMIF irradiation matrices. (author)

  10. Standard practice for preparation and use of direct tension stress-corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This practice covers procedures for designing, preparing, and using ASTM standard tension test specimens for investigating susceptibility to stress-corrosion cracking. Axially loaded specimens may be stressed quantitatively with equipment for application of either a constant load, constant strain, or with a continuously increasing strain. 1.2 Tension test specimens are adaptable for testing a wide variety of product forms as well as parts joined by welding, riveting, or various other methods. 1.3 The exposure of specimens in a corrosive environment is treated only briefly because other standards are being prepared to deal with this aspect. Meanwhile, the investigator is referred to Practices G35, G36, G37, and G44, and to ASTM Special Technical Publication 425 (1).

  11. Expanding severe acute respiratory infection (SARI) surveillance beyond influenza: The process and data from 1 year of implementation in Vietnam.

    Science.gov (United States)

    Alroy, Karen A; Do, Trang Thuy; Tran, Phu Dac; Dang, Tan Quang; Vu, Long Ngoc; Le, Nga Thi Hang; Dang, Anh Duc; Ngu, Nghia Duy; Ngo, Tu Huy; Hoang, Phuong Vu Mai; Phan, Lan Trong; Nguyen, Thuong Vu; Nguyen, Long Thanh; Nguyen, Thinh Viet; Vien, Mai Quang; Le, Huy Xuan; Dao, Anh The; Nguyen, Trieu Bao; Pham, Duoc Tho; Nguyen, Van Thi Tuyet; Pham, Thanh Ngoc; Phan, Binh Hai; Whitaker, Brett; Do, Thuy Thi Thu; Dao, Phuong Anh; Balajee, S Arunmozhi; Mounts, Anthony W

    2018-05-13

    In 2016, as a component of the Global Health Security Agenda, the Vietnam Ministry of Health expanded its existing influenza sentinel surveillance for severe acute respiratory infections (SARI) to include testing for 7 additional viral respiratory pathogens. This article describes the steps taken to implement expanded SARI surveillance in Vietnam and reports data from 1 year of expanded surveillance. The process of expanding the suite of pathogens for routine testing by real-time reverse transcriptase-polymerase chain reaction (rRT-PCR) included laboratory trainings, procurement/distribution of reagents, and strengthening and aligning SARI surveillance epidemiology practices at sentinel sites and regional institutes (RI). Surveillance data showed that of 4003 specimens tested by the RI laboratories, 20.2% (n = 810) were positive for influenza virus. Of the 3193 influenza-negative specimens, 41.8% (n = 1337) were positive for at least 1 non-influenza respiratory virus, of which 16.2% (n = 518), 13.4% (n = 428), and 9.6% (n = 308) tested positive for respiratory syncytial virus, rhinovirus, and adenovirus, respectively. The Government of Vietnam has demonstrated that expanding respiratory viral surveillance by strengthening and building upon an influenza platform is feasible, efficient, and practical. © 2018 The Authors. Influenza and Other Respiratory Viruses Published by John Wiley & Sons Ltd.

  12. Experimental and Numerical Evaluation of Direct Tension Test for Cylindrical Concrete Specimens

    Directory of Open Access Journals (Sweden)

    Jung J. Kim

    2014-01-01

    Full Text Available Concrete cracking strength can be defined as the tensile strength of concrete subjected to pure tension stress. However, as it is difficult to apply direct tension load to concrete specimens, concrete cracking is usually quantified by the modulus of rupture for flexural members. In this study, a new direct tension test setup for cylindrical specimens (101.6 mm in diameter and 203.2 mm in height similar to those used in compression test is developed. Double steel plates are used to obtain uniform stress distributions. Finite element analysis for the proposed test setup is conducted. The uniformity of the stress distribution along the cylindrical specimen is examined and compared with rectangular cross section. Fuzzy image pattern recognition method is used to assess stress uniformity along the specimen. Moreover, the probability of cracking at different locations along the specimen is evaluated using probabilistic finite element analysis. The experimental and numerical results of the cracking location showed that gravity effect on fresh concrete during setting time might affect the distribution of concrete cracking strength along the height of the structural elements.

  13. A curved beam test specimen for determining the interlaminar tensile strength of a laminated composite

    Science.gov (United States)

    Hiel, Clement C.; Sumich, Mark; Chappell, David P.

    1991-01-01

    A curved beam type of test specimen is evaluated for use in determining the through-the-thickness strength of laminated composites. Two variations of a curved beam specimen configuration (semicircular and elliptical) were tested to failure using static and fatigue loads. The static failure load for the semicircular specimens was found to be highly sensitive to flaw content, with the specimens falling into two distinct groups. This result supports the use of proof testing for structural validation. Static design allowables are derived based on the Weibull distribution. Fatigue data indicates no measured increase in specimen compliance prior to final fracture. All static and fatigue failures at room temperature dry conditions occurred catastrophically. The elliptical specimens demonstrated unusually high failure strengths indicating the presence of phenomena requiring further study. Results are also included for specimens exposed to a wet environment showing a matrix strength degradation due to moisture content. Further testing is underway to evaluate a fatigue methodology for matrix dominated failures based on residual static strength (wearout).

  14. Extended result reading window in lateral flow tests detecting exposure to Onchocerca volvulus: a new technology to improve epidemiological surveillance tools.

    Directory of Open Access Journals (Sweden)

    Allison Golden

    Full Text Available Onchocerciasis is a neglected tropical disease caused by infection with the parasite Onchocerca volvulus (Ov. An estimated 180 million people are at risk for Ov infection, and 37 million people are infected, mostly in Africa. A lateral flow-based assay to detect human IgG4 antibodies to the Ov-specific antigen Ov-16 was developed as a rapid tool to detect exposure to Ov. The test, when performed on 449 sera specimens from patients with microfiladermia and Ov-negative patients, has a sensitivity of 89.1% (95% confidence interval: 86.2%-92.0%, and specificity of 97% (95% confidence interval: 95.4%-98.6%. Because the intended use of the test is for surveillance, it is highly desirable to have a stable, long-lasting result. An extended read window is thus desirable for a high-volume, busy workflow and facilitates post-surveillance quality assurance. The main restriction on achieving an extended read window for this assay was the erythrocyte lysis that can alter the signal-to-noise ratio, especially in those with low IgG4 levels (weak positives. We describe a test housing that incorporates a user-independent feature driven by assay fluid and an expanding wick that detaches the blood separation membrane from the nitrocellulose used in the assay, but before hemolysis occurs. We demonstrated material functionality at extreme operational conditions (37°C, 80% relative humidity and a read window of a minimum of 70 days. The fluid-driven assay device performs equally as well with whole blood as with plasma, as demonstrated with 100 spiked clinical specimens (with a correlation coefficient of 0.96. We show a novel, inexpensive, and simple approach to actuating the detachment of the blood separation membrane from the nitrocellulose test with no impact on the performance characteristics of the test.

  15. Thermal endurance tests on silicone rubber specimens

    International Nuclear Information System (INIS)

    Warburton, C.

    1977-07-01

    Thermal endurance tests have been performed on a range of silicone rubber specimens at temperature above 300 0 C. It is suggested that the rubber mix A2426, the compound from which Wylfa sealing rings are manufactured, will fail at temperatures above 300 0 C within weeks. Hardness measurements show that this particular rubber performs in a similar manner to Walker's S.I.L./60. (author)

  16. The detection of tightly closed flaws by nondestructive testing (NDT) methods. [fatigue crack formation in aluminum alloy test specimens

    Science.gov (United States)

    Rummel, W. D.; Rathke, R. A.; Todd, P. H., Jr.; Mullen, S. J.

    1975-01-01

    Liquid penetrant, ultrasonic, eddy current and X-radiographic techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens in integrally stiffened panel, and weld panel configurations. Fatigue cracks in integrally stiffened panels, lack-of-fusion in weld panels, and fatigue cracks in weld panels were the flaw types used for evaluation. A 2319 aluminum alloy weld filler rod was used for all welding to produce the test specimens. Forty seven integrally stiffened panels containing a total of 146 fatigue cracks, ninety three lack-of-penetration (LOP) specimens containing a total of 239 LOP flaws, and one-hundred seventeen welded specimens containing a total of 293 fatigue cracks were evaluated. Nondestructive test detection reliability enhancement was evaluated during separate inspection sequences in the specimens in the 'as-machined or as-welded', post etched and post proof loaded conditions. Results of the nondestructive test evaluations were compared to the actual flaw size obtained by measurement of the fracture specimens after completing all inspection sequences. Inspection data were then analyzed to provide a statistical basis for determining the flaw detection reliability.

  17. Correlations between Standard and Miniaturised Charpy-V Specimens

    International Nuclear Information System (INIS)

    Lucon, E.; Van Walle, E.; Fabry, A.; Puzzolante, J.-L.; Verstrepen, A.; Vosch, R.; Van de Velde, L.

    1998-12-01

    A total of 565 instrumented impact tests (232 performed on full-size and 333 on sub-size Charpy-V specimens) have been analysed in order to derive meaningful assumptions on the correlations existing between test results obtained on specimens of different size. Nine materials (pressure vessel steels) have been considered, in both as-received and irradiated state, for a total of 19 conditions examined. For the analysis of data, conventional as well novel approaches have been investigated; former ones, based on a review of the existing literature, include predictions of USE values by the use of normalization factors (NF), shifts of index temperatures related to energy/lateral expansion/shear fracture levels, and a combination of both approaches (scaling and shifting of energy curves). More original and recent proposals have also been verified, available in the literature but also proposed by SCK-CEN in the frame of enhanced surveillance of nuclear reactor pressure vessels. Conclusions have been drawn regarding the applicability and reliability of these methodologies, and recommendations have been given for future developments of the activities on this topic

  18. HER2 testing on core needle biopsy specimens from primary breast cancers: interobserver reproducibility and concordance with surgically resected specimens

    International Nuclear Information System (INIS)

    Tsuda, Hitoshi; Kurosumi, Masafumi; Umemura, Shinobu; Yamamoto, Sohei; Kobayashi, Takayuki; Osamura, Robert Yoshiyuki

    2010-01-01

    Accurate evaluation of human epidermal growth factor receptor type-2 (HER2) status based on core needle biopsy (CNB) specimens is mandatory for identification of patients with primary breast cancer who will benefit from primary systemic therapy with trastuzumab. The aim of the present study was to validate the application of HER2 testing with CNB specimens from primary breast cancers in terms of interobserver reproducibility and comparison with surgically resected specimens. A total of 100 pairs of archival formalin-fixed paraffin-embedded CNB and surgically resected specimens of invasive breast carcinomas were cut into sections. All 100 paired sections were subjected to HER2 testing by immunohistochemistry (IHC) and 27 paired sections were subjected to that by fluorescence in situ hybridization (FISH), the results being evaluated by three and two observers, respectively. Interobserver agreement levels in terms of judgment and the concordance of consensus scores between CNB samples and the corresponding surgically resected specimens were estimated as the percentage agreement and κ statistic. In CNB specimens, the percentage interobserver agreement of HER2 scoring by IHC was 76% (κ = 0.71) for 3 × 3 categories (0-1+ versus 2+ versus 3+) and 90% (κ = 0.80) for 2 × 2 categories (0-2+ versus 3+). These levels were close to the corresponding ones for the surgically resected specimens: 80% (κ = 0.77) for 3 × 3 categories and 92% (κ = 0.88) for 2 × 2 categories. Concordance of consensus for HER2 scores determined by IHC between CNB and the corresponding surgical specimens was 87% (κ = 0.77) for 3 × 3 categories, and 94% (κ = 0.83) for 2 × 2 categories. Among the 13 tumors showing discordance in the mean IHC scores between the CNB and surgical specimens, the results of consensus for FISH results were concordant in 11. The rate of successful FISH analysis and the FISH positivity rate in cases with a HER2 IHC score of 2+ differed among specimens processed at

  19. HER2 testing on core needle biopsy specimens from primary breast cancers: interobserver reproducibility and concordance with surgically resected specimens

    Directory of Open Access Journals (Sweden)

    Yamamoto Sohei

    2010-10-01

    Full Text Available Abstract Background Accurate evaluation of human epidermal growth factor receptor type-2 (HER2 status based on core needle biopsy (CNB specimens is mandatory for identification of patients with primary breast cancer who will benefit from primary systemic therapy with trastuzumab. The aim of the present study was to validate the application of HER2 testing with CNB specimens from primary breast cancers in terms of interobserver reproducibility and comparison with surgically resected specimens. Methods A total of 100 pairs of archival formalin-fixed paraffin-embedded CNB and surgically resected specimens of invasive breast carcinomas were cut into sections. All 100 paired sections were subjected to HER2 testing by immunohistochemistry (IHC and 27 paired sections were subjected to that by fluorescence in situ hybridization (FISH, the results being evaluated by three and two observers, respectively. Interobserver agreement levels in terms of judgment and the concordance of consensus scores between CNB samples and the corresponding surgically resected specimens were estimated as the percentage agreement and κ statistic. Results In CNB specimens, the percentage interobserver agreement of HER2 scoring by IHC was 76% (κ = 0.71 for 3 × 3 categories (0-1+ versus 2+ versus 3+ and 90% (κ = 0.80 for 2 × 2 categories (0-2+ versus 3+. These levels were close to the corresponding ones for the surgically resected specimens: 80% (κ = 0.77 for 3 × 3 categories and 92% (κ = 0.88 for 2 × 2 categories. Concordance of consensus for HER2 scores determined by IHC between CNB and the corresponding surgical specimens was 87% (κ = 0.77 for 3 × 3 categories, and 94% (κ = 0.83 for 2 × 2 categories. Among the 13 tumors showing discordance in the mean IHC scores between the CNB and surgical specimens, the results of consensus for FISH results were concordant in 11. The rate of successful FISH analysis and the FISH positivity rate in cases with a HER2 IHC score of

  20. Application of small specimens to fracture mechanics characterization of irradiated pressure vessel steels

    International Nuclear Information System (INIS)

    Sokolov, M.A.; Wallin, K.; McCabe, D.E.

    1996-01-01

    In this study, precracked Charpy V-notch (PCVN) specimens were used to characterize the fracture toughness of unirradiated and irradiated reactor pressure vessel steels in the transition region by means of three-point static bending. Fracture toughness at cleavage instability was calculated in terms of elastic-plastic K Jc values. A statistical size correction based upon weakest-link theory was performed. The concept of a master curve was applied to analyze fracture toughness properties. Initially, size-corrected PCVN data from A 533 grade B steel, designated HSST Plate O2, were used to position the master curve and a 5% tolerance bound for K Jc data. By converting PCVN data to IT compact specimen equivalent K Jc data, the same master curve and 5% tolerance bound curve were plotted against the Electric Power Research Institute valid linear-elastic K Jc database and the ASME lower bound K Ic curve. Comparison shows that the master curve positioned by testing several PCVN specimens describes very well the massive fracture toughness database of large specimens. These results give strong support to the validity of K Jc with respect to K Ic in general and to the applicability of PCVN specimens to measure fracture toughness of reactor vessel steels in particular. Finally, irradiated PCVN specimens of other materials were tested, and the results are compared to compact specimen data. The current results show that PCVNs demonstrate very good capacity for fracture toughness characterization of reactor pressure vessel steels. It provides an opportunity for direct measurement of fracture toughness of irradiated materials by means of precracking and testing Charpy specimens from surveillance capsules. However, size limits based on constraint theory restrict the operational test temperature range for K Jc data from PCVN specimens. 13 refs., 8 figs., 1 tab

  1. Surveillance test interval optimization

    International Nuclear Information System (INIS)

    Cepin, M.; Mavko, B.

    1995-01-01

    Technical specifications have been developed on the bases of deterministic analyses, engineering judgment, and expert opinion. This paper introduces our risk-based approach to surveillance test interval (STI) optimization. This approach consists of three main levels. The first level is the component level, which serves as a rough estimation of the optimal STI and can be calculated analytically by a differentiating equation for mean unavailability. The second and third levels give more representative results. They take into account the results of probabilistic risk assessment (PRA) calculated by a personal computer (PC) based code and are based on system unavailability at the system level and on core damage frequency at the plant level

  2. Recent experiences and problems in conducting pressure vessel surveillance examinations

    International Nuclear Information System (INIS)

    Perrin, J.S.

    1979-01-01

    Each of the commercial power reactors in the U.S.A. has a pressure vessel surveillance program. The purpose of the programs is to monitor the effects of radiation on the mechanical properties on the steel pressure vessels. A program for a given reactor includes a series of irradiation capsules containing neutron dosimeters and mechanical property specimens. The capsules are periodically removed during the life of the reactor and evaluated. The surveillance capsule examinations conducted to date have been valuable in assessing the effects of radiation on pressure vessels. However, a number of problems have been observed in the course of capsule examinations which potentially could reduce the maximum value of the data obtained. These problems are related to specimen design and preparation, capsule design and preparation, capsule installation and removal, capsule disassembly, specimen testing and evaluation, program documentation, and quality assurance. Examples of problems encountered in the preceding areas are presented in the present paper, and recommendations are made for minimization or prevention of these problems in future programs. Included in the recommendations is that appropriate ASTM standards, ASME Boiler and Pressure Vessel Code sections, and NRC regulations provide the appropriate framework for prevention of problems

  3. Comparison of gross anatomy test scores using traditional specimens vs. QuickTime Virtual Reality animated specimens

    Science.gov (United States)

    Maza, Paul Sadiri

    movie modules. The comparison of the two sample group means of the examinations show that there was no difference in results between using QTVR movie modules to test gross anatomy knowledge versus using physical specimens. The results of this study are discussed to explain the benefits of using such computer based anatomy resources in gross anatomy assessments.

  4. Acquisition and preparation of specimens of rock for large-scale testing

    International Nuclear Information System (INIS)

    Watkins, D.J.

    1981-01-01

    The techniques used for acquisition and preparation of large specimens of rock for laboratory testing depend upon the location of the specimen, the type of rock and the equipment available at the sampling site. Examples are presented to illustrate sampling and preparation techniques used for two large cylindrical samples of granitic material, one pervasively fractured and one containing a single fracture

  5. Validatin of miniaturised tensile testing on DMLS TI6AL4V (ELI specimens

    Directory of Open Access Journals (Sweden)

    Van Zyl, Ian

    2016-11-01

    Full Text Available Direct metal laser sintering (DMLS is a relatively new technology that is developing rapidly. Since DMLS material is created by melting/solidifying tracks and layers from powder, even building geometry can influence the mechanical properties. To certify a material, the testing specimens must be designed and manufactured according to the appropriate standards. Miniaturised tensile DMLS samples could be a good alternative for express quality control, and could reduce the cost of DMLS-specific testing. In this study, as-built and stress-relieved miniaturised tensile DMLS Ti6Al4V (ELI specimens with different surface qualities were investigated. The fracture surfaces and mechanical properties of the mini-tensile specimens were analysed and compared with standard full-sized specimens also manufactured by DMLS. The obtained data showed the applicability of mini-tensile tests for the express analysis of DMLS objects if a correction factor is applied for the calculation of the load-bearing cross-section of the specimen.

  6. Computer vision applied to herbarium specimens of German trees: testing the future utility of the millions of herbarium specimen images for automated identification.

    Science.gov (United States)

    Unger, Jakob; Merhof, Dorit; Renner, Susanne

    2016-11-16

    Global Plants, a collaborative between JSTOR and some 300 herbaria, now contains about 2.48 million high-resolution images of plant specimens, a number that continues to grow, and collections that are digitizing their specimens at high resolution are allocating considerable recourses to the maintenance of computer hardware (e.g., servers) and to acquiring digital storage space. We here apply machine learning, specifically the training of a Support-Vector-Machine, to classify specimen images into categories, ideally at the species level, using the 26 most common tree species in Germany as a test case. We designed an analysis pipeline and classification system consisting of segmentation, normalization, feature extraction, and classification steps and evaluated the system in two test sets, one with 26 species, the other with 17, in each case using 10 images per species of plants collected between 1820 and 1995, which simulates the empirical situation that most named species are represented in herbaria and databases, such as JSTOR, by few specimens. We achieved 73.21% accuracy of species assignments in the larger test set, and 84.88% in the smaller test set. The results of this first application of a computer vision algorithm trained on images of herbarium specimens shows that despite the problem of overlapping leaves, leaf-architectural features can be used to categorize specimens to species with good accuracy. Computer vision is poised to play a significant role in future rapid identification at least for frequently collected genera or species in the European flora.

  7. Stress-deformed state of cylindrical specimens during indirect tensile strength testing

    Directory of Open Access Journals (Sweden)

    Levan Japaridze

    2015-10-01

    Full Text Available In this study, the interaction between cylindrical specimen made of homogeneous, isotropic, and linearly elastic material and loading jaws of any curvature is considered in the Brazilian test. It is assumed that the specimen is diametrically compressed by elliptic normal contact stresses. The frictional contact stresses between the specimen and platens are neglected. The analytical solution starts from the contact problem of the loading jaws of any curvature and cylindrical specimen. The contact width, corresponding loading angle (2θ0, and elliptical stresses obtained through solution of the contact problems are used as boundary conditions for a cylindrical specimen. The problem of the theory of elasticity for a cylinder is solved using Muskhelishvili's method. In this method, the displacements and stresses are represented in terms of two analytical functions of a complex variable. In the main approaches, the nonlinear interaction between the loading bearing blocks and the specimen as well as the curvature of their surfaces and the elastic parameters of their materials are taken into account. Numerical examples are solved using MATLAB to demonstrate the influence of deformability, curvature of the specimen and platens on the distribution of the normal contact stresses as well as on the tensile and compressive stresses acting across the loaded diameter. Derived equations also allow calculating the modulus of elasticity, total deformation modulus and creep parameters of the specimen material based on the experimental data of radial contraction of the specimen.

  8. Polystyrene cryostat facilitates testing tensile specimens under liquid nitrogen

    Science.gov (United States)

    Shogan, R. P.; Skalka, R. J.

    1967-01-01

    Lightweight cryostat made of expanded polystyrene reduces eccentricity in a tensile system being tested under liquid nitrogen. The cryostat is attached directly to the tensile system by a special seal, reducing misalignment effects due to cryostat weight, and facilitates viewing and loading of the specimens.

  9. Remote replacement of materials open-test assembly specimens at the FFTF/IEM cell

    International Nuclear Information System (INIS)

    Gibbons, P.W.; Ramsey, E.B.

    1990-01-01

    The Fast Flux Test Facility (FFTF) interim examination and maintenance (IEM) cell is used for the remote disassembly of irradiated fuel and materials experiments. The materials open-test assembly (MOTA) is brought to the IEM cell for materials test specimen removal. The specimens are shipped to the materials laboratory for sorting and installation in new specimen holders and then returned within 10 days to the IEM cell where they are installed in a new MOTA vehicle for further irradiation. Reconstituting a MOTA is a challenging remote operation involving dozens of steps and two separate facilities. Handling and disassembling sodium-wetted components pose interesting handling, cleaning, and disposal challenges. The success of this system is evidenced by its timely completion in the critical path of FFTF outage schedules

  10. Standard test method for laboratory evaluation of magnesium sacrificial anode test specimens for underground applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a laboratory procedure that measures the two fundamental performance properties of magnesium sacrificial anode test specimens operating in a saturated calcium sulfate, saturated magnesium hydroxide environment. The two fundamental properties are electrode (oxidation potential) and ampere hours (Ah) obtained per unit mass of specimen consumed. Magnesium anodes installed underground are usually surrounded by a backfill material that typically consists of 75 % gypsum (CaSO4·2H2O), 20 % bentonite clay, and 5 % sodium sulfate (Na2SO4). The calcium sulfate, magnesium hydroxide test electrolyte simulates the long term environment around an anode installed in the gypsum-bentonite-sodium sulfate backfill. 1.2 This test method is intended to be used for quality assurance by anode manufacturers or anode users. However, long term field performance properties may not be identical to property measurements obtained using this laboratory test. Note 1—Refer to Terminology G 15 for terms used ...

  11. Miniature specimen technology for postirradiation fatigue crack growth testing

    International Nuclear Information System (INIS)

    Mervyn, D.A.; Ermi, A.M.

    1979-01-01

    Current magnetic fusion reactor design concepts require that the fatigue behavior of candidate first wall materials be characterized. Fatigue crack growth may, in fact, be the design limiting factor in these cyclic reactor concepts given the inevitable presence of crack-like flaws in fabricated sheet structures. Miniature specimen technology has been developed to provide the large data base necessary to characterize irradiation effects on the fatigue crack growth behavior. An electrical potential method of measuring crack growth rates is employed on miniature center-cracked-tension specimens (1.27 cm x 2.54 cm x 0.061 cm). Results of a baseline study on 20% cold-worked 316 stainless steel, which was tested in an in-cell prototypic fatigue machine, are presented. The miniature fatigue machine is designed for low cost, on-line, real time testing of irradiated fusion candidate alloys. It will enable large scale characterization and development of candidate first wall alloys

  12. Analysis of the percentage voids of test and field specimens using computerized tomography

    International Nuclear Information System (INIS)

    Braz, D.; Lopes, R.T.; Motta, L.M.G. da

    1999-01-01

    Computerized tomography has been an excellent tool of analysis of asphaltics mixtures, because it allows comparison of the quality and integrity of test and field specimens. It was required to detect and follow the evolution of cracks, when these mixtures were submitted to fatigue tests, and also helping to interpret the distribution of tensions and deformations which occur in the several types of solicitations imposed to the mixtures. Comparing the medium values of percentage voids obtained from tomographic images with the project's values, it can be observed that the values of test and field specimens for the wearing course are closer to the ones of the project than the ones of the binder. It can be verified that the wearing course specimens always present a distribution of the aggregate, and voids quite homogeneously in the whole profile of the sample, while the binder specimens show an accentuated differentiation of the same factors in the several heights of the sample. Therefore, when choosing a slice for tomography, these considerations should be taken into account

  13. Fracture mechanics investigations within the swiss surveillance programme for the pressure vessel of modern nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Ullrich, G; Krompholz, K [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1994-12-31

    In the frame of surveillance programmes of Swiss nuclear power plants, irradiation tests have been performed on tensile, impact and wedge opening load specimens as well as on three point bend-type specimens (for J-integral investigations) and pre-cracked Charpy impact specimens (for dynamical stress intensities K{sub ID}). An experimental method (potential drop technique) is used together with a mathematical procedure which allow for the determination of the stress intensity K{sub IC} for small CT-samples instead of large ones: agreement of these both methods is found excellent, and the mapping of both methods to fatigue pre-cracked small specimens (3 PB and Charpy) is possible. The application of the analysis method to dynamical tests is also possible. 15 refs., 9 figs., 1 tab.

  14. Corrosion testing of uranium silicide fuel specimens

    International Nuclear Information System (INIS)

    Bourns, W.T.

    1968-09-01

    U 3 Si is the most promising high density natural uranium fuel for water-cooled power reactors. Power reactors fuelled with this material are expected to produce cheaper electricity than those fuelled with uranium dioxide. Corrosion tests in 300 o C water preceded extensive in-reactor performance tests of fuel elements and bundles. Proper heat-treatment of U-3.9 wt% Si gives a U 3 5i specimen which corrodes at less than 2 mg/cm 2 h in 300 o C water. This is an order of magnitude lower than the maximum corrosion rate tolerable in a water-cooled reactor. U 3 Si in a defected unbonded Zircaloy-2 sheath showed only a slow uniform sheath expansion in 300 o C water. All tests were done under isothermal conditions in an out-reactor loop. (author)

  15. Repeat confirmatory testing for persons with discordant whole blood and oral fluid rapid HIV test results: findings from post marketing surveillance.

    Directory of Open Access Journals (Sweden)

    Laura G Wesolowski

    Full Text Available BACKGROUND: Reactive oral fluid and whole blood rapid HIV tests must be followed with a confirmatory test (Western blot (WB, immunofluorescent assay (IFA or approved nucleic acid amplification test (NAAT. When the confirmatory result is negative or indeterminate (i.e. discordant with rapid result, repeat confirmatory testing should be conducted using a follow-up specimen. Previous reports have not described whether repeat testing adequately resolves the HIV-infection status of persons with discordant results. METHODOLOGY: Post-marketing surveillance was conducted in 368 testing sites affiliated with 14 state and 2 city health departments from August 11, 2004 to June 30, 2005 and one health department through December 31, 2005. For persons with discordant results, data were collected on demographics, risk behaviors, HIV test results and specimen types. Persons with repeat confirmatory results were classified as HIV-infected or uninfected. Regression models were created to assess risk factors for not having repeat testing. PRINCIPAL FINDINGS: Of 167,371 rapid tests conducted, 2589 (1.6% were reactive: of these, 2417 (93% had positive WB/IFA, 172 (7% had negative or indeterminate WB/IFA. Of 89/172 (52% persons with a repeat confirmatory test: 17 (19% were HIV-infected, including 3 with indeterminate WB and positive NAAT; 72 (81% were uninfected, including 12 with repeat indeterminate WB. Factors associated with HIV-infection included having an initial indeterminate WB/IFA (vs. negative (p<0.001 and having an initial oral fluid WB (vs. serum (p<0.001. Persons who had male-female sex (vs. male-male sex were at increased risk for not having a repeat test [adjusted OR 2.6, 95% CI (1.3, 4.9]. CONCLUSIONS: Though only half of persons with discordant results had repeat confirmatory testing, of those who did, nearly one in five were HIV-infected. These findings underscore the need for rapid HIV testing programs to increase repeat confirmatory testing for

  16. Analysis of the applicability of fracture mechanics on the basis of large scale specimen testing

    International Nuclear Information System (INIS)

    Brumovsky, M.; Polachova, H.; Sulc, J.; Anikovskij, V.; Dragunov, Y.; Rivkin, E.; Filatov, V.

    1988-01-01

    The verification is dealt with of fracture mechanics calculations for WWER reactor pressure vessels by large scale model testing performed on the large testing machine ZZ 8000 (maximum load of 80 MN) in the Skoda Concern. The results of testing a large set of large scale test specimens with surface crack-type defects are presented. The nominal thickness of the specimens was 150 mm with defect depths between 15 and 100 mm, the testing temperature varying between -30 and +80 degC (i.e., in the temperature interval of T ko ±50 degC). Specimens with a scale of 1:8 and 1:12 were also tested, as well as standard (CT and TPB) specimens. Comparisons of results of testing and calculations suggest some conservatism of calculations (especially for small defects) based on Linear Elastic Fracture Mechanics, according to the Nuclear Reactor Pressure Vessel Codes which use the fracture mechanics values from J IC testing. On the basis of large scale tests the ''Defect Analysis Diagram'' was constructed and recommended for brittle fracture assessment of reactor pressure vessels. (author). 7 figs., 2 tabs., 3 refs

  17. Corrosion testing of uranium silicide fuel specimens

    Energy Technology Data Exchange (ETDEWEB)

    Bourns, W T

    1968-09-15

    U{sub 3}Si is the most promising high density natural uranium fuel for water-cooled power reactors. Power reactors fuelled with this material are expected to produce cheaper electricity than those fuelled with uranium dioxide. Corrosion tests in 300{sup o}C water preceded extensive in-reactor performance tests of fuel elements and bundles. Proper heat-treatment of U-3.9 wt% Si gives a U{sub 3}5i specimen which corrodes at less than 2 mg/cm{sup 2} h in 300{sup o}C water. This is an order of magnitude lower than the maximum corrosion rate tolerable in a water-cooled reactor. U{sub 3}Si in a defected unbonded Zircaloy-2 sheath showed only a slow uniform sheath expansion in 300{sup o}C water. All tests were done under isothermal conditions in an out-reactor loop. (author)

  18. Standard practice for preparation and use of Bent-Beam stress-corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This practice covers procedures for designing, preparing, and using bent-beam stress-corrosion specimens. 1.2 Different specimen configurations are given for use with different product forms, such as sheet or plate. This practice applicable to specimens of any metal that are stressed to levels less than the elastic limit of the material, and therefore, the applied stress can be accurately calculated or measured (see Note 1). Stress calculations by this practice are not applicable to plastically stressed specimens. Note 1—It is the nature of these practices that only the applied stress can be calculated. Since stress-corrosion cracking is a function of the total stress, for critical applications and proper interpretation of results, the residual stress (before applying external stress) or the total elastic stress (after applying external stress) should be determined by appropriate nondestructive methods, such as X-ray diffraction (1). 1.3 Test procedures are given for stress-corrosion testing by ex...

  19. Characteristics of the IAEA correlation monitor material for surveillance programmes

    International Nuclear Information System (INIS)

    Wallin, K.; Valo, M.; Rintamaa, R.; Toerroenen, K.

    1989-08-01

    Within the IAEA Coordinated Research Programme on optimizing of reactor pressure vessel surveillance programmes and their analysis, phase 3, a specially tailored 'radiation sensitive' correlation monitor material has been fabricated. This material will serve as a reference to the IAEA programme for future vessel surveillance programmes throughout the world. An extensive evaluation of the correlation monitor material in the as-received condition has been carried out in Finland and the results are presented here. The mechanical properties measured at different temperatures include Charpy V notch and instrumented precracked Charpy data, and elastic-plastic fracture toughness (J). The specimen size and geometry have been varied in the tests. Correlation between different fracture properties are evaluated and discussed

  20. Development of resistance welding process. 4. Preparation of pressuring enclosed creep test specimen of 7A material

    International Nuclear Information System (INIS)

    Endo, Hideo; Seki, Masayuki; Ishibashi, Fujio; Hirako, Kazuhito; Tsukada, Tatsuya

    2001-02-01

    Mechanical strength in the position welded by resistance welding system was examined in 1999. The test specimens were destroyed in the welding position in a shorter time than expected in the creep test. Therefore, test specimens were prepared to evaluate the cause of destruction. Inner-pressure enclosed creep test specimens were prepared by resistance welding method. Cladding material with low deviation of thickness and high re-crystallization rate was used. Heat treatment after resistance welding was performed to remove the influence of residual stress and the precipitation of carbides. (1) Before preparation of specimens, the welding condition was fixed. Three test specimens were prepared. Two specimens without heat treatment were transported to MMS in Oarai Engineering Center on Aug. 4, 2000. One specimen with heat treatment was transported to MMS after evaluating the residual stress to get optimum heat treatment condition. (2) Specimens were prepared with welding end plugs to both ends of ferritic ODS cladding. Enclosing sides were welded with highly strong Ferritic/Martensitic steel end plugs. The other sides were welded with ferritic ODS end plugs. (3) Some kinds of electrical wave data were obtained during performing welding. Welding position was evaluated with supersonic detector after performing welding. (4) Mechanical strength of welding position in high temperature 800degC was confirmed to be equal to or larger than that of cladding material. The highly qualified specimens in the present were successfully prepared. (author)

  1. Critical assessment of precracked specimen configuration and experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate

    Science.gov (United States)

    Domack, M. S.

    1985-01-01

    A research program was conducted to critically assess the effects of precracked specimen configuration, stress intensity solutions, compliance relationships and other experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate. Modified compact and double beam wedge-loaded specimens were tested and analyzed to determine the threshold stress intensity factor and stress corrosion crack growth rate. Stress intensity solutions and experimentally determined compliance relationships were developed and compared with other solutions available in the literature. Crack growth data suggests that more effective crack length measurement techniques are necessary to better characterize stress corrosion crack growth. Final load determined by specimen reloading and by compliance did not correlate well, and was considered a major source of interlaboratory variability. Test duration must be determined systematically, accounting for crack length measurement resolution, time for crack arrest, and experimental interferences. This work was conducted as part of a round robin program sponsored by ASTM committees G1.06 and E24.04 to develop a standard test method for stress corrosion testing using precracked specimens.

  2. Evaluation of a Spotted Fever Group Rickettsia Public Health Surveillance System in Tennessee.

    Science.gov (United States)

    Fill, Mary-Margaret A; Moncayo, Abelardo C; Bloch, Karen C; Dunn, John R; Schaffner, William; Jones, Timothy F

    2017-09-01

    Spotted fever group (SFG) rickettsioses are endemic in Tennessee, with ∼2,500 cases reported during 2000-2012. Because of this substantial burden of disease, we performed a three-part evaluation of Tennessee's routine surveillance for SFG rickettsioses cases and deaths to assess the system's effectiveness. Tennessee Department of Health (TDH) SFG rickettsioses surveillance records were matched to three patient series: 1) patients with positive serologic specimens from a commercial reference laboratory during 2010-2011, 2) tertiary medical center patients with positive serologic tests during 2007-2013, and 3) patients identified from death certificates issued during 1995-2014 with SFG rickettsiosis-related causes of death. Chart reviews were performed and patients were classified according to the Council of State and Territorial Epidemiologists' case definition. Of 254 SFG Rickettsia -positive serologic specimens from the reference laboratory, 129 (51%) met the case definition for confirmed or probable cases of rickettsial disease after chart review. The sensitivity of the TDH surveillance system to detect cases was 45%. Of the 98 confirmed or probable cases identified from the medical center, the sensitivity of the TDH surveillance system to detect cases was 34%. Of 27 patients identified by death certificates, 12 (44%) were classified as confirmed or probable cases; four (33%) were reported to TDH, but none were correctly identified as deceased. Cases of SFG rickettsioses were underreported and fatalities not correctly identified. Efforts are needed to improve SFG rickettsiosis surveillance in Tennessee.

  3. Results of EMC market surveillance tests for UPS systems

    Energy Technology Data Exchange (ETDEWEB)

    Rajamaeki, J. [Safety Technology Authority, Helsinki (Finland)

    1997-12-31

    This paper reports the first wide electromagnetic compatibility (EMC) market surveillance project in Finland in which the uninterruptible power systems (UPS) on the Finnish market are monitored. Altogether 11 UPS units are EMC tested and the results of these tests are described in this paper. The effect of basic characters of UPS on the level of electromagnetic interference are analysed. (orig.) 3 refs.

  4. Testing of mobile surveillance robot at a nuclear power plant

    International Nuclear Information System (INIS)

    White, J.R.; Harvey, H.W.; Farnstrom, K.A.

    1987-01-01

    In-plant testing of a mobile surveillance robot (SURBOT) was performed at the Browns Ferry Nuclear Plant by TVA personnel. The results verified that SURBOT can be used for remote surveillance in 54 separate controlled radiation rooms at the plant. High-quality color video, audio, and other data are collected, digitized by an on-board computer, and transmitted through a cable to the control console for real-time display and videotaping. TVA projects that the use of SURBOT for surveillance during plant operation will produce annual savings of about 100 person-rem radiation exposure and $200,000 in operating costs. Based on the successful results of this program, REMOTEC is now commercializing the SURBOT technology on both wheeled and tracked mobile robots for use in nuclear power plants and other hazardous environments

  5. Small Scale Yielding Correction of Constraint Loss in Small Sized Fracture Toughness Test Specimens

    International Nuclear Information System (INIS)

    Kim, Maan Won; Kim, Min Chul; Lee, Bong Sang; Hong, Jun Hwa

    2005-01-01

    Fracture toughness data in the ductile-brittle transition region of ferritic steels show scatter produced by local sampling effects and specimen geometry dependence which results from relaxation in crack tip constraint. The ASTM E1921 provides a standard test method to define the median toughness temperature curve, so called Master Curve, for the material corresponding to a 1T crack front length and also defines a reference temperature, T 0 , at which median toughness value is 100 MPam for a 1T size specimen. The ASTM E1921 procedures assume that high constraint, small scaling yielding (SSY) conditions prevail at fracture along the crack front. Violation of the SSY assumption occurs most often during tests of smaller specimens. Constraint loss in such cases leads to higher toughness values and thus lower T 0 values. When applied to a structure with low constraint geometry, the standard fracture toughness estimates may lead to strongly over-conservative estimates. A lot of efforts have been made to adjust the constraint effect. In this work, we applied a small-scale yielding correction (SSYC) to adjust the constraint loss of 1/3PCVN and PCVN specimens which are relatively smaller than 1T size specimen at the fracture toughness Master Curve test

  6. Confirmation tests of PWR surveillance capsule shipping container

    International Nuclear Information System (INIS)

    Tomita, N.; Ue, K.; Ohashi, M.; Asada, K.; Yoneda, Y.

    1980-01-01

    Mitsubishi Heavy Industries, Ltd. carried out the confirmation tests to confirm the reliability of the PWR surveillance capsule shipping container and to collect cask design data using a 10-ton weight full scale model at Kobe Shipyard and Engine Works. This report presents the outline of these tests. The B Type container was a cylinder 3289 mm long, 1080 mm in diameter and designed in accordance with the new modified Japanese regulations similar to IAEA regulation. These tests consist of four 9 m drop tests, two 1 m puncture tests, a fire test and an immersion test. In conclusion, safetyness of this container has been proved and various technical data for cask design were also collected through these tests. (author)

  7. Stress Wave Attenuation in Aluminum Alloy and Mild Steel Specimens Under SHPB Tensile Testing

    Science.gov (United States)

    Pothnis, J. R.; Ravikumar, G.; Arya, H.; Yerramalli, Chandra S.; Naik, N. K.

    2018-02-01

    Investigations on the effect of intensity of incident pressure wave applied through the striker bar on the specimen force histories and stress wave attenuation during split Hopkinson pressure bar (SHPB) tensile testing are presented. Details of the tensile SHPB along with Lagrangian x- t diagram of the setup are included. Studies were carried out on aluminum alloy 7075 T651 and IS 2062 mild steel. While testing specimens using the tensile SHPB setup, it was observed that the force calculated from the transmitter bar strain gauge was smaller than the force obtained from the incident bar strain gauge. This mismatch between the forces in the incident bar and the transmitter bar is explained on the basis of stress wave attenuation in the specimens. A methodology to obtain force histories using the strain gauges on the specimen during SHPB tensile testing is also presented. Further, scanning electron microscope images and photomicrographs are given. Correlation between the microstructure and mechanical properties is explained. Further, uncertainty analysis was conducted to ascertain the accuracy of the results.

  8. Comparison between instrumented precracked Charpy and compact specimen tests of carbon steels

    International Nuclear Information System (INIS)

    Nanstad, R.K.

    1980-01-01

    The General Atomic Company High Temperature Gas-Cooled Reactor (HTGR) is housed within a prestressed concrete reactor vessel (PCRV). Various carbon steel structural members serve as closures at penetrations in the vessel. A program of testing and evaluation is underway to determine the need for reference fracture toughness (K/sub IR/) and indexing procedures for these materials as described in Appendix G to Section III, ASME Code for light water reactor steels. The materials of interest are carbon steel forgings (SA508, Class 1) and plates (SA537, Classes 1 and 2) as well as weldments of these steels. The fracture toughness behavior is characterized with instrumented precracked Charpy V-votch specimens (PCVN) - slow-bend and dynamic - and compact specimens (10-mm and 25-mm thicknesses) using both linear elastic (ASTM E399) and elastic-plastic (equivalent Energy and J-Integral) analytical procedures. For the dynamic PCVN tests, force-time traces are analyzed according to the procedures of the Pressure Vessel Research Council (PVRC)/Metal Properties Council (MPC). Testing and analytical procedures are discussed and PCVN results are compared to those obtained with compact specimens

  9. Screening test recommendations for methicillin-resistant Staphylococcus aureus surveillance practices: A cost-minimization analysis.

    Science.gov (United States)

    Whittington, Melanie D; Curtis, Donna J; Atherly, Adam J; Bradley, Cathy J; Lindrooth, Richard C; Campbell, Jonathan D

    2017-07-01

    To mitigate methicillin-resistant Staphylococcus aureus (MRSA) infections, intensive care units (ICUs) conduct surveillance through screening patients upon admission followed by adhering to isolation precautions. Two surveillance approaches commonly implemented are universal preemptive isolation and targeted isolation of only MRSA-positive patients. Decision analysis was used to calculate the total cost of universal preemptive isolation and targeted isolation. The screening test used as part of the surveillance practice was varied to identify which screening test minimized inappropriate and total costs. A probabilistic sensitivity analysis was conducted to evaluate the range of total costs resulting from variation in inputs. The total cost of the universal preemptive isolation surveillance practice was minimized when a polymerase chain reaction screening test was used ($82.51 per patient). Costs were $207.60 more per patient when a conventional culture was used due to the longer turnaround time and thus higher isolation costs. The total cost of the targeted isolation surveillance practice was minimized when chromogenic agar 24-hour testing was used ($8.54 per patient). Costs were $22.41 more per patient when polymerase chain reaction was used. For ICUs that preemptively isolate all patients, the use of a polymerase chain reaction screening test is recommended because it can minimize total costs by reducing inappropriate isolation costs. For ICUs that only isolate MRSA-positive patients, the use of chromogenic agar 24-hour testing is recommended to minimize total costs. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  10. Application of DNA barcoding in forest biosecurity surveillance programs

    Science.gov (United States)

    Leland M. Humble; Jeremy R. deWaard

    2011-01-01

    The ability to distinguish non-indigenous species from the background diversity of native taxa is critical to the success of surveillance programs for detecting new introductions. Surveillance programs for alien taxa rely on the precise diagnosis of species, which can be complicated by sizable trap samples, damaged specimens, immature life stages, and incomplete...

  11. Influence of Specimen Preparation and Test Methods on the Flexural Strength Results of Monolithic Zirconia Materials.

    Science.gov (United States)

    Schatz, Christine; Strickstrock, Monika; Roos, Malgorzata; Edelhoff, Daniel; Eichberger, Marlis; Zylla, Isabella-Maria; Stawarczyk, Bogna

    2016-03-09

    The aim of this work was to evaluate the influence of specimen preparation and test method on the flexural strength results of monolithic zirconia. Different monolithic zirconia materials (Ceramill Zolid (Amann Girrbach, Koblach, Austria), Zenostar ZrTranslucent (Wieland Dental, Pforzheim, Germany), and DD Bio zx² (Dental Direkt, Spenge, Germany)) were tested with three different methods: 3-point, 4-point, and biaxial flexural strength. Additionally, different specimen preparation methods were applied: either dry polishing before sintering or wet polishing after sintering. Each subgroup included 40 specimens. The surface roughness was assessed using scanning electron microscopy (SEM) and a profilometer whereas monoclinic phase transformation was investigated with X-ray diffraction. The data were analyzed using a three-way Analysis of Variance (ANOVA) with respect to the three factors: zirconia, specimen preparation, and test method. One-way ANOVA was conducted for the test method and zirconia factors within the combination of two other factors. A 2-parameter Weibull distribution assumption was applied to analyze the reliability under different testing conditions. In general, values measured using the 4-point test method presented the lowest flexural strength values. The flexural strength findings can be grouped in the following order: 4-point strength values than prepared before sintering. The Weibull moduli ranged from 5.1 to 16.5. Specimens polished before sintering showed higher surface roughness values than specimens polished after sintering. In contrast, no strong impact of the polishing procedures on the monoclinic surface layer was observed. No impact of zirconia material on flexural strength was found. The test method and the preparation method significantly influenced the flexural strength values.

  12. C.O.D. toughness testing of medium strength steel as a preliminary development for single specimen J integral toughness tests of SA533-B steel

    International Nuclear Information System (INIS)

    Dean, P.; Tait, R.B.; Garrett, G.G.

    1981-10-01

    The primary purpose of this project is to set up a test facility and to develop the necessary expertise to enable reliable elasto-plastic fracture toughness tests to be performed. Initially, tests are to be conducted on material similar to that used in the Koeberg pressure vessel walls, with the ultimate goal of performing single specimen J integral tests on the pressure vessel steel itself to determine through-thickness toughness variations. The project will comprise a number of stages, each one necessary for the development of the techniques used in J integral testing. These include: (i) development of an appropriate specimen design, of suitable size and shape that is applicable to both crack opening displacement (C.O.D.) and J integral tests; (ii) development, testing and calibration of the necessary associated mechanical and electrical equipment (e.g. clip gauge, amplifiers, interface unit, etc.), with (iii) an estimation of the probable errors and noise levels with a view to their elimantion, leading to (iv) perfection of the sensitivity and reproducibility of, firstly, the multiple specimen C.O.D. technique and, secondly, the multiple specimen J integral techniques. (v) Based on the above techniques, development of the single specimen J integral test method incorporating development of a computerised testing procedure. All the above procedure is to be conducted on similar, but non-Koeberg pressure vessel material ('ROQ Tough'). (vi) Finally, development and testing of both multiple specimen and single specimen J integral tests on actual SA533B material and an investigation of the through thickness toughness and fatigue crack propagation behaviour

  13. LOCA scenario tests of irradiated fuel rod specimens

    International Nuclear Information System (INIS)

    Scott, Harold

    2004-01-01

    Full text: The NRC's cladding performance program at Argonne National Laboratory (ANL) is testing fueled high-burnup segments subjected to LOCA integral phenomena. The data are provided to NRC and the nuclear industry for their independent assessment of the adequacy of licensing criteria for LOCA events. The tests are being conducted with high-burnup 30 cm segments from Limerick (9x9 Zry-2) and H.B. Robinson (15x15 Zry-4) reactors. Prior to testing, sibling samples are characterized with respect to fuel morphology, fuel-cladding bond, cladding oxide layer thickness, hydrogen content and high-temperature steam oxidation kinetics. Specimens that survive quench are subjected to four-point bend tests, followed by local diametral compression tests. The retention of post-quench ductility is a more limiting requirement than surviving thermal stresses during quench. Companion tests are conducted with unirradiated cladding to generate baseline data for comparison with the high-burnup fuel results. LOCA integral tests have the following sequential steps: stabilization of temperature, internal pressure and steam flow at 300 C, ramping of temperature (∼5C/s) through ballooning and burst to 1204 C, hold at 1204 C for 1-5 minutes, slow-cooling (∼3C/s) to 800 C, and water quenching at ∼800C. Two high-burnup tests were completed in 2002 with Limerick BWR rod segments: ramp to burst in argon followed by slow cooling; and the LOCA test with 5-minute hold time at 1204 C, followed by slow cooling. With the exception of burst-opening shape, results for burst temperature, burst pressure, burst length, and ballooning strain profile are more similar to, than different from, results for unirradiated Zry-2 cladding exposed to the same time-temperature history. The 3rd Limerick test with quench was performed in December 2003, and a 4th Limerick test was performed in March 2004. Tests on high-burnup Robinson PWR fuel segments are scheduled to begin in June 2004. The presentation points

  14. Impact of specimen adequacy on the assessment of renal allograft biopsy specimens.

    Science.gov (United States)

    Cimen, S; Geldenhuys, L; Guler, S; Imamoglu, A; Molinari, M

    2016-01-01

    The Banff classification was introduced to achieve uniformity in the assessment of renal allograft biopsies. The primary aim of this study was to evaluate the impact of specimen adequacy on the Banff classification. All renal allograft biopsies obtained between July 2010 and June 2012 for suspicion of acute rejection were included. Pre-biopsy clinical data on suspected diagnosis and time from renal transplantation were provided to a nephropathologist who was blinded to the original pathological report. Second pathological readings were compared with the original to assess agreement stratified by specimen adequacy. Cohen's kappa test and Fisher's exact test were used for statistical analyses. Forty-nine specimens were reviewed. Among these specimens, 81.6% were classified as adequate, 6.12% as minimal, and 12.24% as unsatisfactory. The agreement analysis among the first and second readings revealed a kappa value of 0.97. Full agreement between readings was found in 75% of the adequate specimens, 66.7 and 50% for minimal and unsatisfactory specimens, respectively. There was no agreement between readings in 5% of the adequate specimens and 16.7% of the unsatisfactory specimens. For the entire sample full agreement was found in 71.4%, partial agreement in 20.4% and no agreement in 8.2% of the specimens. Statistical analysis using Fisher's exact test yielded a P value above 0.25 showing that - probably due to small sample size - the results were not statistically significant. Specimen adequacy may be a determinant of a diagnostic agreement in renal allograft specimen assessment. While additional studies including larger case numbers are required to further delineate the impact of specimen adequacy on the reliability of histopathological assessments, specimen quality must be considered during clinical decision making while dealing with biopsy reports based on minimal or unsatisfactory specimens.

  15. Design of creep machine and creep specimen chamber for carrying out creep tests in flowing liquid sodium

    Energy Technology Data Exchange (ETDEWEB)

    Ravi, S., E-mail: sravi@igcar.gov.in; Laha, K.; Sakthy, S.; Mathew, M.D.; Jayakumar, T.

    2014-02-15

    Highlights: • Design of a lever type creep machine for carrying out creep test in flowing sodium. • Leveling of lever during creep was achieved by automated movement of fulcrum. • Design of creep chamber for providing constant sodium flow rate across creep specimen. • Minimum use of bellow in chamber for sodium containment and mechanical isolation. • Mini-lever mechanism to counter balance load reduction on specimen due to bellow stiffness. - Abstract: A creep testing system has been designed, fabricated, installed and validated for carrying out creep tests in flowing liquid sodium. The testing system consists of two sections namely creep testing machine and an environmental chamber. The testing system has the ability of (i) applying tensile load to the test specimen through a lever, (ii) monitoring continuously the creep elongation and (iii) allowing sodium to flow around the creep specimen at constant velocity. The annular space between the creep specimen and the environmental chamber has been suitably designed to maintain constant sodium flow velocity. Primary and secondary bellows are employed in the environmental chamber to (i) mechanically isolate the creep specimen, (ii) prevent the flowing sodium in contact with air and (iii) maintain an argon gas cover to the leaking sodium if any from primary bellow, with a provision to an alarm get activated by a spark plug. The lever-horizontality during creep test has been maintained by automatically lifting up the fulcrum instead of lowering down the pull rod as conventionally used. A mini lever mechanism has been incorporated in the load train to counter balance the load reduction on specimen from the changing stiffness of the bellows. The validation of the testing system has been established by carrying out creep tests on 316L(N) stainless steel at 873 K over a wide stress range and comparing the results with those obtained in air by employing the developed and conventional creep testing machines.

  16. Expressed prostatic secretion biomarkers improve stratification of NCCN active surveillance candidates: performance of secretion capacity and TMPRSS2:ERG models.

    Science.gov (United States)

    Whelan, Christopher; Kawachi, Mark; Smith, David D; Linehan, Jennifer; Babilonia, Gail; Mejia, Rosa; Wilson, Timothy; Smith, Steven S

    2014-01-01

    Active surveillance is a viable patient option for prostate cancer provided that a clinical determination of low risk and presumably organ confined disease can be made. To standardize risk stratification schemes the NCCN (National Comprehensive Cancer Network®) provides guidelines for the active surveillance option. We determined the effectiveness of expressed prostatic secretion biomarkers for detecting occult risk factors in NCCN active surveillance candidates. Expressed prostatic secretion specimens were obtained before robot-assisted radical prostatectomy. Secretion capacity biomarkers, including total RNA and expressed prostatic secretion specimen volume, were measured by standard techniques. RNA expression biomarkers, including TXNRD1 mRNA, prostate specific antigen mRNA, TMPRSS2:ERG fusion mRNA and PCA3 mRNA, were measured by quantitative reverse-transcription polymerase chain reaction. Of the 528 patients from whom expressed prostatic secretions were collected 216 were eligible for active surveillance under NCCN guidelines. Variable selection on logistic regression identified 2 models, including one featuring types III and VI TMPRSS2:ERG variants, and one featuring 2 secretion capacity biomarkers. Of the 2 high performing models the secretion capacity model was most effective for detecting cases in this group that were up-staged or up-staged plus upgraded. It decreased the risk of up-staging in patients with a negative test almost eightfold and decreased the risk of up-staging plus upgrading about fivefold while doubling the prevalence of up-staging in the positive test group. Noninvasive expressed prostatic secretion testing may improve patient acceptance of active surveillance by dramatically reducing the presence of occult risk factors among those eligible for active surveillance under NCCN guidelines. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  17. Stress corrosion cracking tests on electron beam welded carbon steel specimens in carbonate-bicarbonate solution

    International Nuclear Information System (INIS)

    Parkins, R.N.

    1985-04-01

    Stress corrosion cracking tests have been performed on tapered carbon steel test pieces containing electron beam welds with a view to defining susceptibility to such cracking in a carbonate-bicarbonate solution at 90 C and an appropriate electrode potential. The tests involved applying cyclic loads to the specimens and it is shown that the threshold stress for cracking reduces linearly with increase in the magnitude of the cyclic load component. Extrapolation of these trends to zero fluctuating stress indicates static load threshold stresses in the vicinity of the yield stress (i.e. about 300 N/mm 2 for parent plate without a weld, 400 N/mm 2 for specimens with welds on one side only and 600 N/mm 2 for specimens having welds penetrating through the thickness of the specimen). The averages of the maximum crack velocities observed were least for parent plate material and greatest for weld metal, the former being essentially intergranular in morphology and the latter mostly transgranular, with heat affected zone material being intermediate between these extremes. (author)

  18. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false How long does the laboratory retain specimens after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How...

  19. Conversion of fracture toughness testing values from small scale three point bending test specimens to small scale yielding state (SSY) by elastic-plastic stress analysis

    International Nuclear Information System (INIS)

    Ikonen, K.

    1993-07-01

    The report describes the work performed for achieving readiness to calculate fracture toughness dependence on dimension effects and loading conditions in fracture test specimens and real structures. In the report two- and three-dimensional computer codes developed and calculational methods applied are described. One of the main goals is to converse fracture toughness from small scale three point bending test specimens to case of a depth crack in plane strain i.e. to small scale yielding state (SSY) by numerical elastic-plastic stress analysis. Thickness effect of a test specimens and effect of a crack depth are separately investigated. Tests of three point bending specimens with and without sidegrooves and curved crack front are numerically simulated and experimental and computed results are compared. J-integral is calculated along crack front and also from force-deflection dependence of the beam. For the analyses the computing system was thoroughly automatized. Measuring capacity of three point bending test specimens was tried to evaluate. (orig.) (7 refs., 54 figs.)

  20. The Effect of Specimen Size on the Results of Concrete Adiabatic Temperature Rise Test with Commercially Available Equipment

    Directory of Open Access Journals (Sweden)

    Byung Jae Lee

    2014-12-01

    Full Text Available In this study, adiabatic temperature rise tests depending on binder type and adiabatic specimen volume were performed, and the maximum adiabatic temperature rises and the reaction factors for each mix proportion were analyzed and suggested. The results indicated that the early strength low heat blended cement mixture had the lowest maximum adiabatic temperature rise (Q∞ and the ternary blended cement mixture had the lowest reaction factor (r. Also, Q and r varied depending on the adiabatic specimen volume even when the tests were conducted with a calorimeter, which satisfies the recommendations for adiabatic conditions. Test results show a correlation: the measurements from the 50 L specimens were consistently higher than those from the 6 L specimens. However, the Q∞ and r values of the 30 L specimen were similar to those of the 50 L specimen. Based on the above correlation, the adiabatic temperature rise of the 50 L specimen could be predicted using the results of the 6 L and 30 L specimens. Therefore, it is thought that this correlation can be used for on-site concrete quality control and basic research.

  1. The Effect of Specimen Size on the Results of Concrete Adiabatic Temperature Rise Test with Commercially Available Equipment.

    Science.gov (United States)

    Lee, Byung Jae; Bang, Jin Wook; Shin, Kyung Joon; Kim, Yun Yong

    2014-12-08

    In this study, adiabatic temperature rise tests depending on binder type and adiabatic specimen volume were performed, and the maximum adiabatic temperature rises and the reaction factors for each mix proportion were analyzed and suggested. The results indicated that the early strength low heat blended cement mixture had the lowest maximum adiabatic temperature rise ( Q ∞ ) and the ternary blended cement mixture had the lowest reaction factor ( r ). Also, Q and r varied depending on the adiabatic specimen volume even when the tests were conducted with a calorimeter, which satisfies the recommendations for adiabatic conditions. Test results show a correlation: the measurements from the 50 L specimens were consistently higher than those from the 6 L specimens. However, the Q ∞ and r values of the 30 L specimen were similar to those of the 50 L specimen. Based on the above correlation, the adiabatic temperature rise of the 50 L specimen could be predicted using the results of the 6 L and 30 L specimens. Therefore, it is thought that this correlation can be used for on-site concrete quality control and basic research.

  2. Evaluating surveillance indicators supporting the Global Polio Eradication Initiative, 2011-2012.

    Science.gov (United States)

    2013-04-12

    The Global Polio Eradication Initiative (GPEI) was established in 1988 by the World Health Assembly to interrupt transmission of wild poliovirus (WPV); completion of this initiative was declared a programmatic emergency of public health in January 2012. Polio cases are detected through surveillance for acute flaccid paralysis (AFP) with linked stool specimens tested for polioviruses (PVs) at accredited laboratories within the Global Polio Laboratory Network (GPLN). AFP surveillance findings are supplemented by testing sewage samples (environmental surveillance) collected at selected sites. Virologic data guide where targeted immunization activities should be conducted or improved. Key performance indicators are used to 1) monitor AFP surveillance quality at national and subnational levels to identify gaps where PV transmission could occur undetected; 2) provide evidence of where PV circulation has been interrupted; and 3) allow timely detection of an outbreak. Standardized surveillance indicators allow progress to be monitored over time and compared among countries. This report presents AFP surveillance performance indicators at national and subnational levels for countries affected by polio during 2011-2012, and trends in environmental surveillance, updating previous reports. In the 19 countries with transmission of PV (WPV and/or circulating vaccine-derived poliovirus [cVDPV]) during 2011-2012, national performance indicator targets were met in 12 (63%) countries in 2011 and 13 (68%) countries in 2012. Seven countries (37%) in 2011 had ≥80% of the population living in areas meeting performance indicators, increasing to nine countries (47%) in 2012. Performance indicators for timely reporting of PV isolation and characterization were met in four of six World Health Organization (WHO) regions in 2011 and five regions in 2012. To achieve global polio eradication, efforts are needed to improve and maintain AFP surveillance and laboratory performance.

  3. Estimating infection attack rates and severity in real time during an influenza pandemic: analysis of serial cross-sectional serologic surveillance data.

    Directory of Open Access Journals (Sweden)

    Joseph T Wu

    2011-10-01

    Full Text Available In an emerging influenza pandemic, estimating severity (the probability of a severe outcome, such as hospitalization, if infected is a public health priority. As many influenza infections are subclinical, sero-surveillance is needed to allow reliable real-time estimates of infection attack rate (IAR and severity.We tested 14,766 sera collected during the first wave of the 2009 pandemic in Hong Kong using viral microneutralization. We estimated IAR and infection-hospitalization probability (IHP from the serial cross-sectional serologic data and hospitalization data. Had our serologic data been available weekly in real time, we would have obtained reliable IHP estimates 1 wk after, 1-2 wk before, and 3 wk after epidemic peak for individuals aged 5-14 y, 15-29 y, and 30-59 y. The ratio of IAR to pre-existing seroprevalence, which decreased with age, was a major determinant for the timeliness of reliable estimates. If we began sero-surveillance 3 wk after community transmission was confirmed, with 150, 350, and 500 specimens per week for individuals aged 5-14 y, 15-19 y, and 20-29 y, respectively, we would have obtained reliable IHP estimates for these age groups 4 wk before the peak. For 30-59 y olds, even 800 specimens per week would not have generated reliable estimates until the peak because the ratio of IAR to pre-existing seroprevalence for this age group was low. The performance of serial cross-sectional sero-surveillance substantially deteriorates if test specificity is not near 100% or pre-existing seroprevalence is not near zero. These potential limitations could be mitigated by choosing a higher titer cutoff for seropositivity. If the epidemic doubling time is longer than 6 d, then serial cross-sectional sero-surveillance with 300 specimens per week would yield reliable estimates when IAR reaches around 6%-10%.Serial cross-sectional serologic data together with clinical surveillance data can allow reliable real-time estimates of IAR and

  4. COMPARISON BETWEEN WOOD DRYING DEFECT SCORES: SPECIMEN TESTING X ANALYSIS OF KILN-DRIED BOARDS

    Directory of Open Access Journals (Sweden)

    Djeison Cesar Batista

    2015-04-01

    Full Text Available It is important to develop drying technologies for Eucalyptus grandis lumber, which is one of the most planted species of this genus in Brazil and plays an important role as raw material for the wood industry. The general aim of this work was to assess the conventional kiln drying of juvenile wood of three clones of Eucalyptus grandis. The specific aims were to compare the behavior between: i drying defects indicated by tests with wood specimens and conventional kiln-dried boards; and ii physical properties and the drying quality. Five 11-year-old trees of each clone were felled, and only flatsawn boards of the first log were used. Basic density and total shrinkage were determined, and the drying test with wood specimens at 100 °C was carried out. Kiln drying of boards was performed, and initial and final moisture content, moisture gradient in thickness, drying stresses and drying defects were assessed. The defect scoring method was used to verify the behavior between the defects detected by specimen testing and the defects detected in kiln-dried boards. As main results, the drying schedule was too severe for the wood, resulting in a high level of boards with defects. The behavior between the defects in the drying test with specimens and the defects of kiln-dried boards was different, there was no correspondence, according to the defect scoring method.

  5. Miniature tensile test specimens for fusion reactor irradiation studies

    International Nuclear Information System (INIS)

    Klueh, R.L.

    1985-01-01

    Three miniature sheet-type tensile specimens and a miniature rod-type specimen are being used to determine irradiated tensile properties for alloy development for fusion reactors. The tensile properties of type 316 stainless steel were determined with these different specimens, and the results were compared. Reasonably good agreement was observed. However, there were differences that led to recommendations on which specimens are preferred. 4 references, 9 figures, 6 tables

  6. Development of test specimens to obtain the transmission factors to attenuate photons of 0.511 MeV

    International Nuclear Information System (INIS)

    Costa, Jacó Júlio de Souza; Cardoso, Domingos D'Oliveira; Gavazza, Sérgio; Oliveira, Cláudio Luiz de; Morales, Rudnei Karam; Amorim, Aneuri Souza de; Balthar, Mario Cesar Viegas; Oliveira, Luciano Santa Rita

    2017-01-01

    For designing a shielding, it is necessary, mainly, to determine or have access to the following parameters: transmission factors of the material used and type of radiation to be shielded. Cylindrical test specimens with different thicknesses were developed for experimentally obtaining the material transmission factor for shielding calculation. The cylindrical test specimens were made considering the geometric characteristics of the detector, the ease of production and the energy of 0.511 MeV from the 18 F-FDG decay. A type of concrete widely used in Brazil was used in the preparation of the cylindrical test specimens. (author)

  7. Development of test specimens to obtain the transmission factors to attenuate photons of 0.511 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Jacó Júlio de Souza; Cardoso, Domingos D' Oliveira; Gavazza, Sérgio; Oliveira, Cláudio Luiz de; Morales, Rudnei Karam, E-mail: jacojulio@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil); Amorim, Aneuri Souza de; Balthar, Mario Cesar Viegas; Oliveira, Luciano Santa Rita [Centro Tecnológico do Exercito (CETEx), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    For designing a shielding, it is necessary, mainly, to determine or have access to the following parameters: transmission factors of the material used and type of radiation to be shielded. Cylindrical test specimens with different thicknesses were developed for experimentally obtaining the material transmission factor for shielding calculation. The cylindrical test specimens were made considering the geometric characteristics of the detector, the ease of production and the energy of 0.511 MeV from the {sup 18}F-FDG decay. A type of concrete widely used in Brazil was used in the preparation of the cylindrical test specimens. (author)

  8. Testing a symptom-based surveillance system at high-profile gatherings as a preparatory measure for bioterrorism.

    Science.gov (United States)

    Osaka, K; Takahashi, H; Ohyama, T

    2002-12-01

    We tested symptom-based surveillance during the G8 conference in 2000 as a means of detecting outbreaks, including bio-terrorism attacks, promptly. Five categories of symptoms (skin and haemorrhagic, respiratory, gastrointestinal, neurological and unexplained) were adopted for the case definition of the surveillance. The surveillance began I week before the conference, and continued until 1 week after the conference ended. We could not detect any outbreaks during this surveillance. Compared to the existing diagnosis-based surveillance system, symptom-based surveillance has the advantages of timeliness and simplicity. However, poor specificity and difficulties in determining epidemic threshold were important limitations of this system. To increase the specificity of surveillance, it is essential to incorporate rapid laboratory diagnoses into the system.

  9. Test and Analysis Correlation for a Y-Joint Specimen for a Composite Cryotank

    Science.gov (United States)

    Mason, Brian H.; Sleight, David W.; Grenoble, Ray

    2015-01-01

    The Composite Cryotank Technology Demonstration (CCTD) project under NASA's Game Changing Development Program (GCDP) developed space technologies using advanced composite materials. Under CCTD, NASA funded the Boeing Company to design and test a number of element-level joint specimens as a precursor to a 2.4-m diameter composite cryotank. Preliminary analyses indicated that the y-joint in the cryotank had low margins of safety; hence the y-joint was considered to be a critical design region. The y-joint design includes a softening strip wedge to reduce localized shear stresses at the skirt/dome interface. In this paper, NASA-developed analytical models will be correlated with the experimental results of a series of positive-peel y-joint specimens from Boeing tests. Initial analytical models over-predicted the experimental strain gage readings in the far-field region by approximately 10%. The over-prediction was attributed to uncertainty in the elastic properties of the laminate and a mismatch between the thermal expansion of the strain gages and the laminate. The elastic properties of the analytical model were adjusted to account for the strain gage differences. The experimental strain gages also indicated a large non-linear effect in the softening strip region that was not predicted by the analytical model. This non-linear effect was attributed to delamination initiating in the softening strip region at below 20% of the failure load for the specimen. Because the specimen was contained in a thermally insulated box during cryogenic testing to failure, delamination initiation and progression was not visualized during the test. Several possible failure initiation locations were investigated, and a most likely failure scenario was determined that correlated well with the experimental data. The most likely failure scenario corresponded to damage initiating in the softening strip and delamination extending to the grips at final failure.

  10. Apparatus and method for fatigue testing of a material specimen in a high-pressure fluid environment

    Science.gov (United States)

    Wang, Jy-An; Feng, Zhili; Anovitz, Lawrence M; Liu, Kenneth C

    2013-06-04

    The invention provides fatigue testing of a material specimen while the specimen is disposed in a high pressure fluid environment. A specimen is placed between receivers in an end cap of a vessel and a piston that is moveable within the vessel. Pressurized fluid is provided to compression and tension chambers defined between the piston and the vessel. When the pressure in the compression chamber is greater than the pressure in the tension chamber, the specimen is subjected to a compression force. When the pressure in the tension chamber is greater than the pressure in the compression chamber, the specimen is subjected to a tension force. While the specimen is subjected to either force, it is also surrounded by the pressurized fluid in the tension chamber. In some examples, the specimen is surrounded by hydrogen.

  11. Dynamic Toughness Testing of Pre-Cracked Charpy V-Notch Specimens. Convention ELECTRABEL - SCK-CEN

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E

    1999-04-01

    This document describes the experimental and analytical procedures which have been adopted at the laboratories of the Belgian Nuclear Research Centre SCK-CEN for performing dynamic toughness tests on pre-cracked Charpy-V specimens. Such procedures were chosen on the basis of the existing literature on the subject, with several updates in the data analysis stages which reflect more recent developments in fracture toughness testing. Qualification tests have been carried out on PCCv specimens of JRQ steel, in order to assess the reliability of the results obtained; straightforward comparisons with reference data have been performed, as well as more advanced analyses using the Master Curve approach. Aspects related to machine compliance and dynamic tup calibration have also been addressed.

  12. Evaluation of self-swabbing coupled with a telephone health helpline as an adjunct tool for surveillance of influenza viruses in Ontario

    Directory of Open Access Journals (Sweden)

    D. McGolrick

    2016-09-01

    Full Text Available Abstract Background Calls to a telephone health helpline (THHL have been previously evaluated for the ability to monitor specific syndromes, such as fever and influenza-like-illness or gastrointestinal illness. This method of surveillance has been shown to be highly correlated with traditional surveillance methods, and to have potential for early detection of community-based illness. Self-sampling, or having a person take his/her own nasal swab, has also proven successful as a useful method for obtaining a specimen, which may be used for respiratory virus detection. Methods This study describes a self-swabbing surveillance system mediated by a nurse-led THHL in Ontario whereby syndromic surveillance concepts are used to recruit and monitor participants with influenza-like illness. Once recruited, participants collect a nasal specimen obtained by self-swabbing and submit for testing and laboratory confirmation. Enumeration of weekly case counts was used to evaluate the timeliness of the self-swabbing surveillance system through comparison to other respiratory virus and influenza surveillance systems in Ontario. The operational efficiency of the system was also evaluated. Results The mean and median number of days between the day that a participant called the THHL, to the day a package was received at the laboratory for testing were approximately 10.4 and 8.6 days, respectively. The time between self-swab collection and package reception was 4.9 days on average, with a median of 4 days. The self-swabbing surveillance system adequately captured the 2014 influenza B season in a timely manner when compared to other Ontario-based sources of influenza surveillance data from the same year; however, the emergence of influenza B was not detected any earlier than with these other surveillance systems. Influenza A surveillance was also evaluated. Using the THHL self-swabbing system, a peak in the number of cases for influenza A was observed approximately

  13. Metallographic analysis of irradiated RERTR-3 fuel test specimens

    International Nuclear Information System (INIS)

    Meyer, M. K.; Hofman, G. L.; Strain, R. V.; Clark, C. R.; Stuart, J. R.

    2000-01-01

    The RERTR-3 irradiation test was designed to investigate the irradiation behavior of aluminum matrix U-MO alloy dispersion fuels under high-temperature, high-fission-rate conditions. Initial postirradiation examination of RERTR-3 fuel specimens has concentrated on binary U-MO atomized fuels. The rate of matrix aluminum depletion was found to be higher than predictions based on low temperature irradiation data. Wavelength Dispersive X-ray Spectroscopy (WDS) indicates that aluminum is present in the interior of the fuel particles. WDS data is supported by a mass and volume balance calculation performed on the basis of image analysis results. The depletion of matrix aluminum seems to have no detrimental effects on fuel performance under the conditions tested to date

  14. Evaluation of the enterovirus laboratory surveillance system in Denmark, 2010 to 2013

    DEFF Research Database (Denmark)

    Condell, Orla; Midgley, Sofie E; Christiansen, Claus Bohn

    2016-01-01

    The primary aim of the Danish enterovirus (EV) surveillance system is to document absence of poliovirus infection. The conflict in Syria has left many children unvaccinated and movement from areas with polio cases to Europe calls for increased awareness to detect and respond to virus-transmission......The primary aim of the Danish enterovirus (EV) surveillance system is to document absence of poliovirus infection. The conflict in Syria has left many children unvaccinated and movement from areas with polio cases to Europe calls for increased awareness to detect and respond to virus......-transmission in a timely manner. We evaluate the national EV laboratory surveillance, to generate recommendations for system strengthening. The system was analysed for completeness of viral typing analysis and clinical information and timeliness of specimen collection, laboratory results and reporting of clinical...... information. Of 23,720 specimens screened, 2,202 (9.3%) were EV-positive. Submission of cerebrospinal fluid and faecal specimens from primary diagnostic laboratories was 79.5% complete (845/1,063), and varied by laboratory and patient age. EV genotypes were determined in 68.5% (979/1,430) of laboratory...

  15. Fatigue damage observed non-destructively in fibre composite coupon test specimens by X-ray CT

    DEFF Research Database (Denmark)

    Jespersen, Kristine Munk; Mikkelsen, Lars Pilgaard

    2016-01-01

    This study presents a method for monitoring the 3D fatigue damage progression on a micro-structural level in a glass fibre/polymer coupon test specimen by means of laboratory X-ray Computed Tomography (CT). A modified mount and holder made for the standard test samples to fit into the X-ray CT...... scanner along with a tension clamp solution is presented. Initially, the same location of the test specimen is inspected by ex-situ X-ray CT during the fatigue loading history, which shows the damage progression on a micro-structural level. The openings of individual uni-directional (UD) fibre fractures...

  16. SMILE: test to validate the WPS effect with a cylindrical thick-walled specimen

    International Nuclear Information System (INIS)

    Bezdikian, G.; Moinereau, D.; Roos, E.; Kerkhof, K.; Taylor, N.

    2004-01-01

    The Reactor Pressure Vessel (RPV) is an essential component, which is liable to limit the lifetime duration of PWR plants. The assessment of defects in RPV subjected to pressurized thermal shock (PTS) transients made at an European level generally does not necessarily consider the beneficial effect of the load history (Warm Pre-stress, WPS). The SMILE project - Structural Margin Improvements in aged embrittled RPV with Load history Effects - aims to give sufficient elements to demonstrate, to model and to validate the beneficial WPS effect. It also aims to harmonize the different approaches in the national codes and standards regarding the inclusion of the WPS effect in a RPV structural integrity assessment. The project includes significant experimental work on WPS type experiments with C(T) specimens and a PTS type transient experiment on a large component. This paper deals with the results of the PTS type transient experiment on a component-like, specimen subjected to WPS-loading, the so called Validation Test, carried out within the framework of work package WP4. The test specimen consists of a cylindrical thickwalled specimen with a thickness of 40 mm and an outer diameter of 160 mm, provided with an internal fully circumferential crack with a depth of about 15 mm. The specified load path type is Load-Cool-Unload-Fracture (LCUF). (orig.)

  17. Surveillance tests for light-water cooled nuclear power reactor vessels in IMEF

    International Nuclear Information System (INIS)

    Choo, Yong-Sun; Ahn, Sang-Bok; Park, Dae-Gyu; Jung, Yang-Hong; Yoo, Byung-Ok; Oh, Wan-Ho; Baik, Seung-Je; Koo, Dae-Seo; Lee, Key-Soon

    1999-01-01

    The surveillance tests for light-water cooled nuclear power reactor vessels were established to monitor the radiation-induced changes in the mechanical properties of ferritic materials in the beltline according to US NRC 10 CFR 50 App. G, US NRC RG1.99-rev.2, ASTM E185-82 and E185-94 in Irradiated Materials Examination Facility(IMEF). The surveillance capsule was transported from NPPs pool sites to KAERI IMEF by using a shipping cask. The capsule was cut and dismantled by capsule cutting machine and milling machine in M2 hot cell. Charpy tests and tension tests were performed in M5a and M5b hot cells respectively. Especially the EPMA located at hot lab was used to analyze the Ni and Cu wt% composition of base metal and weld for predicting the adjusted reference temperature(ART). The established process and test results were summarized in this paper. (author)

  18. Human-centered automation of testing, surveillance and maintenance

    International Nuclear Information System (INIS)

    Bhatt, S.C.; Sun, B.K.H.

    1991-01-01

    Manual surveillance and testing of instrumentation, control and protection systems at nuclear power plants involves system and human errors which can lead to substantial plant down time. Frequent manual testing can also contribute significantly to operation and maintenance cost. Automation technology offers potential for prudent applications at the power plant to reduce testing errors and cost. To help address the testing problems and to harness the benefit of automation application, input from utilities is obtained on suitable automation approaches. This paper includes lessens from successful past experience at a few plants where some island of automation exist. The results are summarized as a set of specifications for semi automatic testing. A human-centered automation methodology is proposed with the guidelines for optimal human/computer division of tasks given. Implementation obstacles for significant changes of testing practices are identified and methods acceptable to nuclear power plants for addressing these obstacles have been suggested

  19. Post-marketing surveillance of OraQuick whole blood and oral fluid rapid HIV testing.

    Science.gov (United States)

    Wesolowski, Laura G; MacKellar, Duncan A; Facente, Shelley N; Dowling, Teri; Ethridge, Steven F; Zhu, Julia H; Sullivan, Patrick S

    2006-08-01

    Post-marketing surveillance was conducted to monitor the performance of the OraQuick Advance rapid HIV-1/2 antibody test (OraQuick) on whole blood and oral fluid. Surveillance of routinely collected data on clients tested with OraQuick in 368 testing sites affiliated with 17 state and city health departments between 11 August 2004 and 30 June 2005. For whole blood and oral fluid, we report the median (range) health department OraQuick specificity and positive predictive value (PPV), and the number of clients with discordant results (e.g. who had a reactive rapid test not confirmed positive by Western blot or indirect immunofluorescence). At one site with lower than expected oral-fluid specificity, we evaluated whether device expiration, manufacturing lot, operator practices, or device-storage or testing-area temperatures were associated with false-positive tests. During the surveillance period, 135 724 whole blood and 26 066 oral fluid rapid tests were conducted. The median health department whole blood OraQuick specificity was 99.98% (range: 99.73-100%) and PPV was 99.24% (range: 66.67-100%); the median oral fluid specificity was 99.89% (range: 99.44-100%) and PPV was 90.00% (range: 50.00-100%). A total of 124 discordant results were reported from 68 (0.05%) whole blood and 56 (0.22%) oral fluid rapid tests. The oral fluid specificity at the site with excess oral fluid false-positive tests was 98.7% (95% confidence interval: 98.18-99.11%). The increase in false-positive tests at that site was not associated with any specific device characteristic, operator procedure or temperature condition. The specificity of OraQuick performed on whole blood and oral fluid during post-marketing surveillance was compatible with the manufacturer's claim within the package insert. However, one site experienced lower than expected oral fluid specificity. Sites that observe that the specificity of OraQuick is lower than the range indicated in the package insert should notify the

  20. A general mixed mode fracture mechanics test specimen: The DCB-specimen loaded with uneven bending moments

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, B.F.; Joergensen, K.; Oestergaard, R.C. [Risoe National Lab., Materials Dept., Roskilde (Denmark); Jacobsen, T.K. [LM Glasfiber A/S, Lunderskov (Denmark)

    2004-03-01

    A mixed mode specimen is proposed for fracture mechanics characterisation of adhesive joints, laminates and multilayers. The specimen is a double cantilever beam specimen loaded with uneven bending moments at the two free beams. By varying the ratio between the two applied moments, the full mode mixity range from pure mode I to pure mode II can be generated for the same specimen geometry. The specimen allows stable crack growth. In case of large scale crack bridging, mixed mode cohesive laws can be obtained by a J integral based approach. As a preliminary example, fracture of adhesive joints between two glass-fibre laminates was studied. The mixed mode fracture resistance increased with increasing crack length due to fibre cross over bridging, eventually reaching a steady-state level (R-curve behaviour). The steady-state fracture toughness level increased with increasing tangential crack opening displacement. Cohesive stresses were determined by a J integral approach. The deducted shear stress was found to be relative high ({approx} = 20 MPa) in comparison with the normal stress ({approx} = 1 MPa). (au)

  1. Progress in Tissue Specimens Alternative for the Driver Genes Testing of Non-small Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Yan SUN

    2015-06-01

    Full Text Available Target treatment based on driver genes in advanced non-small cell lung cancer is very important currently. Tumor tissues is the gold standard for driver genes testing. However, most of patients could not get the gene information for lack of enough tissues. To explore the tissue specimens alternatives is a hot spot in clinical work. This report reviews the tissue specimen alternatives of driver gene testing in non-small cell lung cancer.

  2. 10 CFR 26.165 - Testing split specimens and retesting single specimens.

    Science.gov (United States)

    2010-01-01

    ... (c), as applicable. If the specimen in Bottle A is free of any evidence of drugs or drug metabolites... suitable inquiry conducted under the provisions of § 26.63 or to any other inquiry or investigation... records must be provided to personnel conducting reviews, inquiries into allegations, or audits under the...

  3. Polio eradication initiative in Africa: influence on other infectious disease surveillance development

    Directory of Open Access Journals (Sweden)

    Cochi Stephen

    2002-12-01

    Full Text Available Abstract Background The World Health Organization (WHO and partners are collaborating to eradicate poliomyelitis. To monitor progress, countries perform surveillance for acute flaccid paralysis (AFP. The WHO African Regional Office (WHO-AFRO and the U.S Centers for Disease Control and Prevention are also involved in strengthening infectious disease surveillance and response in Africa. We assessed whether polio-eradication initiative resources are used in the surveillance for and response to other infectious diseases in Africa. Methods During October 1999-March 2000, we developed and administered a survey questionnaire to at least one key informant from the 38 countries that regularly report on polio activities to WHO. The key informants included WHO-AFRO staff assigned to the countries and Ministry of Health personnel. Results We obtained responses from 32 (84% of the 38 countries. Thirty-one (97% of the 32 countries had designated surveillance officers for AFP surveillance, and 25 (78% used the AFP resources for the surveillance and response to other infectious diseases. In 28 (87% countries, AFP program staff combined detection for AFP and other infectious diseases. Fourteen countries (44% had used the AFP laboratory specimen transportation system to transport specimens to confirm other infectious disease outbreaks. The majority of the countries that performed AFP surveillance adequately (i.e., non polio AFP rate = 1/100,000 children aged Conclusions Despite concerns regarding the targeted nature of AFP surveillance, it is partially integrated into existing surveillance and response systems in multiple African countries. Resources provided for polio eradication should be used to improve surveillance for and response to other priority infectious diseases in Africa.

  4. GHOST: global hepatitis outbreak and surveillance technology.

    Science.gov (United States)

    Longmire, Atkinson G; Sims, Seth; Rytsareva, Inna; Campo, David S; Skums, Pavel; Dimitrova, Zoya; Ramachandran, Sumathi; Medrzycki, Magdalena; Thai, Hong; Ganova-Raeva, Lilia; Lin, Yulin; Punkova, Lili T; Sue, Amanda; Mirabito, Massimo; Wang, Silver; Tracy, Robin; Bolet, Victor; Sukalac, Thom; Lynberg, Chris; Khudyakov, Yury

    2017-12-06

    Hepatitis C is a major public health problem in the United States and worldwide. Outbreaks of hepatitis C virus (HCV) infections associated with unsafe injection practices, drug diversion, and other exposures to blood are difficult to detect and investigate. Effective HCV outbreak investigation requires comprehensive surveillance and robust case investigation. We previously developed and validated a methodology for the rapid and cost-effective identification of HCV transmission clusters. Global Hepatitis Outbreak and Surveillance Technology (GHOST) is a cloud-based system enabling users, regardless of computational expertise, to analyze and visualize transmission clusters in an independent, accurate and reproducible way. We present and explore performance of several GHOST implemented algorithms using next-generation sequencing data experimentally obtained from hypervariable region 1 of genetically related and unrelated HCV strains. GHOST processes data from an entire MiSeq run in approximately 3 h. A panel of seven specimens was used for preparation of six repeats of MiSeq libraries. Testing sequence data from these libraries by GHOST showed a consistent transmission linkage detection, testifying to high reproducibility of the system. Lack of linkage among genetically unrelated HCV strains and constant detection of genetic linkage between HCV strains from known transmission pairs and from follow-up specimens at different levels of MiSeq-read sampling indicate high specificity and sensitivity of GHOST in accurate detection of HCV transmission. GHOST enables automatic extraction of timely and relevant public health information suitable for guiding effective intervention measures. It is designed as a virtual diagnostic system intended for use in molecular surveillance and outbreak investigations rather than in research. The system produces accurate and reproducible information on HCV transmission clusters for all users, irrespective of their level of bioinformatics

  5. Transitioning from antenatal surveillance surveys to routine HIV testing: a turning point in the mother-to-child transmission prevention programme for HIV surveillance in Brazil.

    Science.gov (United States)

    Pereira, Gerson Fernando Mendes; Sabidó, Meritxell; Caruso, Alessandro; Benzaken, Adele Schwartz

    2017-07-05

    In Brazil, due to the rapid increase in programmes for the prevention of mother-to-child transmission (PMTCT), routine programme data are widely available. The objective of this study was to assess the utility of programmatic data to replace HIV surveillance based on the antenatal care (ANC) surveillance survey (SS). We analysed ANC SS data from 219 maternity service clinics. PMTCT variables were extracted from the ANC SS data collection form, which allowed us to capture and compare the ANC SS data and PMTCT HIV test results for each pregnant woman who completed the ANC SS. Both the PMTCT programme and the ANC SS tested for HIV using sequential ELISA and western blot for confirmation. We assessed the completeness (% missing) of the PMTC data included in the ANC SS. Of the 36,713 pregnant women who had ANC SS HIV tests performed, 30,588 also underwent PMTCT HIV testing. The HIV prevalence rate from routine PMTCT testing was 0.36%, compared to 0.38% from the ANC SS testing (relative difference -0.05%; absolute difference -0.02%). The relative difference in prevalence rates between pregnant women in northern Brazil and pregnant women central-west Brazil was -0.98 and 0.66, respectively. Of the 29,856 women who had HIV test results from both the PMTCT and ANC SS, the positive percent agreement of the PMTCT versus the surveillance test was 84.1% (95% confidence interval [CI]: 74.8-91.0), and the negative percent agreement was 99.9% (95% CI: 99.9-100.0). The PMTCT HIV testing uptake was 86.4%. The ANC SS HIV prevalence was 0.33% among PMTCT non-refusers and 0.59% among refusers, with a percent bias of -10.80% and a differential prevalence ratio of 0.56. Syphilis and HIV testing results were complete in 98% and 97.6% of PMTCT reports, respectively. The reported HIV status for the women at clinic entry was missing. Although there were consistent HIV prevalence estimates from the PMTCT data and the ANC SS, the overall positive percent agreement of 84.1% falls below the

  6. A general mixed mode fracture mechanics test specimen: The DCB-specimen loaded with uneven bending moments

    DEFF Research Database (Denmark)

    Sørensen, Bent F.; Jørgensen, K.; Jacobsen, T.K.

    2004-01-01

    A mixed mode specimen is proposed for fracture mechanics characterisation of adhesive joints, laminates and multilayers. The specimen is a double cantilever beam specimen loaded with uneven bending moments at the two free beams. By varying the ratiobetween the two applied moments, the full mode...... glass-fibre laminates was studied. The mixed mode fracture resistance increased with increasing crack length due to fibre bridging, eventually reaching asteady-state level (R-curve behaviour). The steady-state fracture toughness level increased with increasing tangential crack opening displacement....

  7. A labelled discrete choice experiment adds realism to the choices presented: preferences for surveillance tests for Barrett esophagus

    Directory of Open Access Journals (Sweden)

    Donkers Bas

    2009-05-01

    Full Text Available Abstract Background Discrete choice experiments (DCEs allow systematic assessment of preferences by asking respondents to choose between scenarios. We conducted a labelled discrete choice experiment with realistic choices to investigate patients' trade-offs between the expected health gains and the burden of testing in surveillance of Barrett esophagus (BE. Methods Fifteen choice scenarios were selected based on 2 attributes: 1 type of test (endoscopy and two less burdensome fictitious tests, 2 frequency of surveillance. Each test-frequency combination was associated with its own realistic decrease in risk of dying from esophageal adenocarcinoma. A conditional logit model was fitted. Results Of 297 eligible patients (155 BE and 142 with non-specific upper GI symptoms, 247 completed the questionnaire (84%. Patients preferred surveillance to no surveillance. Current surveillance schemes of once every 1–2 years were amongst the most preferred alternatives. Higher health gains were preferred over those with lower health gains, except when test frequencies exceeded once a year. For similar health gains, patients preferred video-capsule over saliva swab and least preferred endoscopy. Conclusion This first example of a labelled DCE using realistic scenarios in a healthcare context shows that such experiments are feasible. A comparison of labelled and unlabelled designs taking into account setting and research question is recommended.

  8. Wildlife specimen collection, preservation, and shipment

    Science.gov (United States)

    White, C. LeAnn; Dusek, Robert J.; Franson, J. Christian; Friend, Milton; Gibbs, Samantha E.J.; Wild, Margaret A.

    2015-01-01

    Specimens are used to provide supporting information leading to the determination of the cause of disease or death in wildlife and for disease monitoring or surveillance. Commonly used specimens for wildlife disease investigations include intact carcasses, tissues from carcasses, euthanized or moribund animals, parasites, ingested food, feces, or environmental samples. Samples from live animals or the environment (e.g., contaminated feed) in the same vicinity as a mortality event also may be helpful. The type of specimen collected is determined by availability of samples and biological objectives. Multiple fresh, intact carcasses from affected species are the most useful in establishing a cause for a mortality event. Submission of entire carcasses allows observation of gross lesions and abnormalities, as well as disease testing of multiple tissues. Samples from live animals may be more appropriate when sick animals cannot be euthanized (e.g., threatened or endangered species) or for research and monitoring projects examining disease or agents circulating in apparently healthy animals or those not exhibiting clinical signs. Samples from live animals may include collections of blood, hair, feathers, feces, or ectoparasites, or samples obtained by swabbing lesions or orifices. Photographs and videos are useful additions for recording field and clinical signs and conveying conditions at the site. Collection of environmental samples (e.g., feces, water, feed, or soil) may be appropriate when animals cannot be captured for sampling or the disease agent may persist in the environment. If lethal collection is considered necessary, biologists should refer to the policies, procedures, and permit requirements of their institution/facility and the agency responsible for species management (U.S. Fish and Wildlife Service or State natural resource agency) prior to use in the field. If threatened or endangered species are found dead, or there is evidence of illegal take, field

  9. Conditional dependence between tests affects the diagnosis and surveillance of animal diseases

    DEFF Research Database (Denmark)

    Gardner, I.A.; Stryhn, Henrik; Lind, Peter

    2000-01-01

    Dependence between the sensitivities or specificities of pairs of tests affects the sensitivity and specificity of tests when used in combination. Compared with values expected if tests are conditionally independent, a positive dependence in test sensitivity reduces the sensitivity of parallel te...... for toxoplasmosis and brucellosis in swine, and Johne's disease in cattle to illustrate calculation methods and to indicate the likely magnitude of the dependence between serologic tests used for diagnosis and surveillance of animal diseases....

  10. Effects of human errors on the determination of surveillance test interval

    International Nuclear Information System (INIS)

    Chung, Dae Wook; Koo, Bon Hyun

    1990-01-01

    This paper incorporates the effects of human error relevant to the periodic test on the unavailability of the safety system as well as the component unavailability. Two types of possible human error during the test are considered. One is the possibility that a good safety system is inadvertently left in a bad state after the test (Type A human error) and the other is the possibility that bad safety system is undetected upon the test (Type B human error). An event tree model is developed for the steady-state unavailability of safety system to determine the effects of human errors on the component unavailability and the test interval. We perform the reliability analysis of safety injection system (SIS) by applying aforementioned two types of human error to safety injection pumps. Results of various sensitivity analyses show that; 1) the appropriate test interval decreases and steady-state unavailability increases as the probabilities of both types of human errors increase, and they are far more sensitive to Type A human error than Type B and 2) the SIS unavailability increases slightly as the probability of Type B human error increases, and significantly as the probability of Type A human error increases. Therefore, to avoid underestimation, the effects of human error should be incorporated in the system reliability analysis which aims at the relaxations of the surveillance test intervals, and Type A human error has more important effect on the unavailability and surveillance test interval

  11. Small specimen test technology of fracture toughness in structural material F82H steel for fusion nuclear reactors

    International Nuclear Information System (INIS)

    Wakai, Eiichi; Ohtsuka, Hideo; Jitsukawa, Shiro; Matsukawa, Shingo; Ando, Masami

    2006-03-01

    Small specimen test technology (SSTT) has been developed to investigate mechanical properties of nuclear materials. SSTT has been driven by limited availability of effective irradiation volumes in test reactors and accelerator-based neutron and charged particle sources, and it is very useful for the reduction of waste materials produced in nuclear engineering. In this study new bend test machines have been developed to obtain fracture behaviors of F82H steel for very small bend specimens of pre-cracked t/2-1/3CVN (Charpy V-notch) with 20 mm-length and DFMB (deformation and fracture mini bend specimen) with 9 mm-length and disk compact tension of 0.18DCT type, and fracture behaviors were examined to evaluate DBTT (ductile-brittle transition temperature) at temperature from -180 to 25degC. The effect of specimen size on DBTT of F82H steel was also examined by using Charpy type specimens such as 1/2t-CVN, 1/3CVN and t/2-1/3CVN. In this paper, it also provides the information of the specimens irradiated at 250degC and 350degC to about 2 dpa in the capsule of 04M-67A and 04M-68A of JMTR experiments. (author)

  12. A retrospective study of owner-requested testing as surveillance for equine infectious anemia in Canada (2009-2012).

    Science.gov (United States)

    Higgins, Sara N; Howden, Krista J; James, Carolyn R; Epp, Tasha; Lohmann, Katharina L

    2017-12-01

    This retrospective study was undertaken to estimate i) the surveillance coverage for equine infectious anemia (EIA) based on owner-requested testing, and ii) the incidence of case detection from this surveillance activity to inform a review of Canada's national disease control strategy. Based on sample submissions by accredited veterinarians to laboratories CFIA-approved for EIA testing between 2009 and 2012, the estimated national surveillance coverage was 14% for all years, and 72 cases of EIA were detected. The annual national incidence of EIA detection ranged from 0.03 to 0.08 cases/1000 horses. On average, a greater proportion of the horse population was tested in eastern Canada (32%) than in western Canada (6%, P Canada (0.25 cases/1000 horses) than in eastern Canada (0.02 cases/1000 horses, P < 0.0001). This study identified regional differences in owner-requested EIA testing and case detection resulting from this testing activity.

  13. Condition For Strain-Hardening In Ecc Uniaxial Test Specimen

    DEFF Research Database (Denmark)

    Dick-Nielsen, Lars; Stang, Henrik; Poulsen, Peter Noe

    2006-01-01

    and infinite sheets under uniaxial tension. The crack is assumed to be cohesive and the cohesive law applied takes into account fiber as well as mortar properties. It is shown that the maximum crack opening observed during crack propagation in various test specimen geometries is small, 20 m and also small......This paper discusses the adequateness of the steady state flat crack criterion for crack propagation in Engineered Cementitious Composites. The investigation is performed by use of a semi-analytical model as well as a Finite Element Model. The simulations are for one crack propagating in finite...

  14. Development of reconstitution technique of irradiated specimens. 3. Report for FY 1995 and FY 1996 on JAERI-IHI cooperated research program (joint research)

    Energy Technology Data Exchange (ETDEWEB)

    Nishiyama, Yutaka; Fukaya, Kiyoshi; Onizawa, Kunio; Suzuki, Masahide [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Nakamura, Terumi; Kaihara, Shoichiro; Yoshida, Kazuo; Sato, Akira

    1998-10-01

    The cooperated research between Japan Atomic Energy Research Institute and Ishikawajima-Harima Heavy Industries Co., Ltd. on the development of reconstitution technique of irradiated reactor pressure vessel surveillance specimens has been performed from FY 1993. In FY 1993-1994, the method of surface activated joining (SAJ) was applied to reconstitution of Charpy impact specimens. Some verification tests using unirradiated reactor pressure vessel plate materials have shown that SAJ is feasible for a reconstitution technique, in particular, owing to low joining temperature. The present paper reports the results of the cooperated research performed in FY 1995-1996. To improve the quality of the SAJ, the configuration of the end tab surface to be joined with the insert material was modified. The torque measured during joining was also introduced in joining parameters. A nondestructive inspection, temperature measurements in the specimens during joining were performed. The effect of joining on Charpy impact properties was discussed. For practical application of the technique to irradiated specimens, we confirmed that the impact specimens with joining interface gave rise to no failure at the joining position during impact test after neutron irradiation. (author)

  15. Design and use of nonstandard tensile specimens for irradiated materials testing

    International Nuclear Information System (INIS)

    Panayotou, N.F.

    1984-10-01

    Miniature, nonstandard, tensile-type specimens have been developed for use in radiation effects experiments at high energy neutron sources where the useful radiation volume is as small as a few cubic centimeters. The end result of our development is a sheet-type specimen, 12.7 mm long with a 5.1 mm long, 1.0 mm wide gage section, which is typically fabricated from 0.25 mm thick sheet stock by a punching technique. Despite this miniature geometry, it has been determined that the data obtained using these miniature specimens are in good agreement with data obtained using much larger specimens. This finding indicates that miniature tensile specimen data may by used for engineering design purposes. Furthermore, it is clear that miniature tensile specimen technology is applicable to fields other than the study of radiation effects. This paper describes the miniature specimen technology which was developed and compares the data obtained from these miniature specimens to data obtained from much larger specimens. 9 figures

  16. The technology development for surveillance test of reactor vessel materials

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Sun Phil; Park, Day Young; Choi, Kwen Jai

    1997-12-01

    Benchmark test was performed in accordance with the requirement of US NRC Reg. Guide DG-1053 for Kori unit-1 in order to determine best-estimated fast neutron fluence irradiated into reactor vessel. Since the uncertainty of radiation analysis comes from the calculation error due to neutron cross-section data, reactor core geometrical dimension, core source, mesh density, angular expansion and convergence criteria, evaluation of calculational uncertainty due to analytical method was performed in accordance with the regulatory guide and the proof was performed for entire analysis by comparing the measurement value obtained by neutron dosimetry located in surveillance capsule. Best-estimated neutron fluence in reactor vessel was calculated by bias factor, neutron flux measurement value/calculational value, from reanalysis result from previous 1st through 4th surveillance testing and finally fluence prediction was performed for the end of reactor life and the entire period of plant life extension. Pressurized thermal shock analysis was performed in accordance with 10 CFR 50.61 using the result of neutron fluence analysis in order to predict the life of reactor vessel material and the criteria of safe operation for Kori unit 1 was reestablished. (author). 55 refs., 55 figs.

  17. Comparison of Three Different Methods for Pile Integrity Testing on a Cylindrical Homogeneous Polyamide Specimen

    Science.gov (United States)

    Lugovtsova, Y. D.; Soldatov, A. I.

    2016-01-01

    Three different methods for pile integrity testing are proposed to compare on a cylindrical homogeneous polyamide specimen. The methods are low strain pile integrity testing, multichannel pile integrity testing and testing with a shaker system. Since the low strain pile integrity testing is well-established and standardized method, the results from it are used as a reference for other two methods.

  18. Small-scale Specimen Testing of Monolithic U-Mo Fuel Foils

    Energy Technology Data Exchange (ETDEWEB)

    Ramprashad Prabhakaran; Douglas E. Burkes; James I. Cole; Indrajit Charit; Daniel M. Wachs

    2008-10-01

    The objective of this investigation is to develop a shear punch testing (SPT) procedure and standardize it to evaluate the mechanical properties of irradiated fuels in a hot-cell so that the tensile behavior can be predicted using small volumes of material and at greatly reduced irradiation costs. This is highly important in the development of low-enriched uranium fuels for nuclear research and test reactors. The load-displacement data obtained using SPT can be interpreted in terms of and correlated with uniaxial mechanical properties. In order to establish a correlation between SPT and tensile data, sub-size tensile and microhardness testing were performed on U-Mo alloys. In addition, efforts are ongoing to understand the effect of test parameters (such as specimen thickness, surface finish, punch-die clearance, crosshead velocity and carbon content) on the measured mechanical properties, in order to rationalize the technique, prior to employing it on a material of unknown strength.

  19. Small-scale Specimen Testing of Monolithic U-Mo Fuel Foils

    International Nuclear Information System (INIS)

    Ramprashad Prabhakaran; Douglas E. Burkes; James I. Cole; Indrajit Charit; Daniel M. Wachs

    2008-01-01

    The objective of this investigation is to develop a shear punch testing (SPT) procedure and standardize it to evaluate the mechanical properties of irradiated fuels in a hot-cell so that the tensile behavior can be predicted using small volumes of material and at greatly reduced irradiation costs. This is highly important in the development of low-enriched uranium fuels for nuclear research and test reactors. The load-displacement data obtained using SPT can be interpreted in terms of and correlated with uniaxial mechanical properties. In order to establish a correlation between SPT and tensile data, sub-size tensile and microhardness testing were performed on U-Mo alloys. In addition, efforts are ongoing to understand the effect of test parameters (such as specimen thickness, surface finish, punch-die clearance, crosshead velocity and carbon content) on the measured mechanical properties, in order to rationalize the technique, prior to employing it on a material of unknown strength

  20. What we learn from surveillance testing of standby turbine driven and motor driven pumps

    International Nuclear Information System (INIS)

    Christie, B.

    1996-01-01

    This paper describes a comparison of the performance information collected by the author and the respective system engineers from five standby turbine driven pumps at four commercial nuclear electric generating units in the United States and from two standby motor driven pumps at two of these generating units. Information was collected from surveillance testing and from Non-Test actuations. Most of the performance information (97%) came from surveillance testing. open-quotes Conditional Probabilitiesclose quotes of the pumps ability to respond to a random demand were calculated for each of the seven standby pumps and compared to the historical record of the Non-Test actuations. It appears that the Conditional Probabilities are comparable to the rate of success for Non-Test actuations. The Conditional Probabilities of the standby motor driven pumps (approximately 99%) are better than the Conditional Probabilities of the standby turbine driven pumps (82%-96% range). Recommendations were made to improve the Conditional Probabilities of the standby turbine driven pumps

  1. What we learn from surveillance testing of standby turbine driven and motor driven pumps

    Energy Technology Data Exchange (ETDEWEB)

    Christie, B.

    1996-12-01

    This paper describes a comparison of the performance information collected by the author and the respective system engineers from five standby turbine driven pumps at four commercial nuclear electric generating units in the United States and from two standby motor driven pumps at two of these generating units. Information was collected from surveillance testing and from Non-Test actuations. Most of the performance information (97%) came from surveillance testing. {open_quotes}Conditional Probabilities{close_quotes} of the pumps ability to respond to a random demand were calculated for each of the seven standby pumps and compared to the historical record of the Non-Test actuations. It appears that the Conditional Probabilities are comparable to the rate of success for Non-Test actuations. The Conditional Probabilities of the standby motor driven pumps (approximately 99%) are better than the Conditional Probabilities of the standby turbine driven pumps (82%-96% range). Recommendations were made to improve the Conditional Probabilities of the standby turbine driven pumps.

  2. Constructing kinetics fatigue diagrams using testing results obtained on a machine with rigid loading for specimens of various thickness

    International Nuclear Information System (INIS)

    Simin'kovich, V.N.; Gladkij, Ya.N.; Deev, N.A.

    1981-01-01

    Bending tests of 40KhS steel specimens, tempered at 200 and 500 deg C, are conducted to investigate the possible effects of specimen thickness on fatigue crack growth. Kinetic fatigue diagrams are constructed using the investigation results. An increase in crack growth with thickness is observed only in high-tempered specimens. Changes in specimen thickness do not affect crack growth in 40KhS low-tempered steel [ru

  3. Uptake of genetic testing and long-term tumor surveillance in von Hippel-Lindau disease

    Directory of Open Access Journals (Sweden)

    Chávez Mireya

    2010-01-01

    Full Text Available Abstract Background von Hippel-Lindau (VHL disease is a hereditary cancer syndrome caused by germline mutations in the VHL gene. Patients have significant morbidity and mortality secondary to vascular tumors. Disease management is centered on tumor surveillance that allows early detection and treatment. Presymptomatic genetic testing is therefore recommended, including in at-risk children. Methods We tested 17 families (n = 109 individuals for VHL mutations including 43 children under the age of 18. Personalized genetic counseling was provided pre and post-test and the individuals undergoing presymptomatic testing filled out questionnaires gathering socio-demographic, psychological and psychiatric data. Mutation analysis was performed by direct sequencing of the VHL gene. Mutation-carriers were screened for VHL disease-related tumors and were offered follow-up annual examinations. Results Mutations were identified in 36 patients, 17 of whom were asymptomatic. In the initial screening, we identified at least one tumor in five of 17 previously asymptomatic individuals. At the end of five years, only 38.9% of the mutation-carriers continued participating in our tumor surveillance program. During this time, 14 mutation carriers developed a total of 32 new tumors, three of whom died of complications. Gender, education, income, marital status and religiosity were not found to be associated with adherence to the surveillance protocol. Follow-up adherence was also independent of pre-test depression, severity of disease, or number of affected family members. The only statistically significant predictor of adherence was being symptomatic at the time of testing (OR = 5; 95% CI 1.2 - 20.3; p = 0.02. Pre-test anxiety was more commonly observed in patients that discontinued follow-up (64.7% vs. 35.3%; p = 0.01. Conclusions The high initial uptake rate of genetic testing for VHL disease, including in minors, allowed the discontinuation of unnecessary screening

  4. Multi-Camera Persistent Surveillance Test Bed

    National Research Council Canada - National Science Library

    Baran, David; O'Brien, Barry; Fung, Nick; Kovach, Jesse; Miller, David

    2007-01-01

    .... Small reconnaissance surveillance and target acquisition (RSTA) platforms have the ability to cooperate through information sharing to increase the situational awareness over a region of interest (RSTA...

  5. Hydrogen embrittlement of titanium tested with fracture mechanics specimens

    International Nuclear Information System (INIS)

    Aho-Mantila, I.; Rahko, P.

    1990-11-01

    Titanium is one of the possible canister materials for spent nuclear fuel. The aim of this study is to determine whether the hydrogen embrittlement of titanium could be a possible deterioration mechanism of titanium canisters. This experimental study was preceded by a literature review and an experimental study on crack nucleation. Tests in this study were carried out with hydrogen charged fracture mechanics specimens. The studied hydrogen contents were as received, 100 ppm, 200 ppm, 500 ppm and 700 ppm and the types of the studied titanium were ASTM Grades 2 and 12. Test methods were slow tensile test (0.027 mm/h) and fatigue test (stress ratio 0.7 or 0.8 and frequency 5 Hz). According to the literature titanium may be embrittled by hydrogen at slow strain rates and cracking may occur under sustained load. In this study no evidence of hydrogen embrittlement was noticed in slow strain rate tension with bulk hydrogen contents up to 700 ppm. The fatigue tests of titanium Grades 2 and 12 containing 700 ppm hydrogen showed even slower crack growth compared to the as received condition. Very high hydrogen contents well in eccess of 700 ppm on the surface of titanium can, however, facilitate surface crack nucleation and crack growth, as shown in the previous study

  6. Clinical Microbiology Laboratories' Adoption of Culture-Independent Diagnostic Tests Is a Threat to Foodborne-Disease Surveillance in the United States.

    Science.gov (United States)

    Shea, Shari; Kubota, Kristy A; Maguire, Hugh; Gladbach, Stephen; Woron, Amy; Atkinson-Dunn, Robyn; Couturier, Marc Roger; Miller, Melissa B

    2017-01-01

    INTRODUCTIONIn November 2015, the Centers for Disease Control and Prevention (CDC) sent a letter to state and territorial epidemiologists, state and territorial public health laboratory directors, and state and territorial health officials. In this letter, culture-independent diagnostic tests (CIDTs) for detection of enteric pathogens were characterized as "a serious and current threat to public health surveillance, particularly for Shiga toxin-producing Escherichia coli (STEC) and Salmonella" The document says CDC and its public health partners are approaching this issue, in part, by "reviewing regulatory authority in public health agencies to require culture isolates or specimen submission if CIDTs are used." Large-scale foodborne outbreaks are a continuing threat to public health, and tracking these outbreaks is an important tool in shortening them and developing strategies to prevent them. It is clear that the use of CIDTs for enteric pathogen detection, including both antigen detection and multiplex nucleic acid amplification techniques, is becoming more widespread. Furthermore, some clinical microbiology laboratories will resist the mandate to require submission of culture isolates, since it will likely not improve patient outcomes but may add significant costs. Specimen submission would be less expensive and time-consuming for clinical laboratories; however, this approach would be burdensome for public health laboratories, since those laboratories would need to perform culture isolation prior to typing. Shari Shea and Kristy Kubota from the Association of Public Health Laboratories, along with state public health laboratory officials from Colorado, Missouri, Tennessee, and Utah, will explain the public health laboratories' perspective on why having access to isolates of enteric pathogens is essential for public health surveillance, detection, and tracking of outbreaks and offer potential workable solutions which will allow them to do this. Marc Couturier of

  7. Reverse-Transcriptase PCR Detection of Leptospira: Absence of Agreement with Single-Specimen Microscopic Agglutination Testing.

    Science.gov (United States)

    Waggoner, Jesse J; Balassiano, Ilana; Mohamed-Hadley, Alisha; Vital-Brazil, Juliana Magalhães; Sahoo, Malaya K; Pinsky, Benjamin A

    2015-01-01

    Reference diagnostic tests for leptospirosis include nucleic acid amplification tests, bacterial culture, and microscopic agglutination testing (MAT) of acute and convalescent serum. However, clinical laboratories often do not receive paired specimens. In the current study, we tested serum samples using a highly sensitive real-time nucleic acid amplification test for Leptospira and compared results to MAT performed on the same specimens. 478 serum samples from suspected leptospirosis cases in Rio de Janeiro were tested using a real-time RT-PCR for the diagnosis of leptospirosis, malaria and dengue (the Lepto-MD assay). The Lepto-MD assay detects all species of Leptospira (saprophytic, intermediate, and pathogenic), and in the current study, we demonstrate that this assay amplifies both Leptospira RNA and DNA. Dengue virus RNA was identified in 10 patients, and no cases of malaria were detected. A total of 65 samples (13.6%) were positive for Leptospira: 35 samples (7.3%) in the Lepto-MD assay, 33 samples (6.9%) by MAT, and 3 samples tested positive by both (kappa statistic 0.02). Poor agreement between methods was consistent regardless of the titer used to define positive MAT results or the day of disease at sample collection. Leptospira nucleic acids were detected in the Lepto-MD assay as late as day 22, and cycle threshold values did not differ based on the day of disease. When Lepto-MD assay results were added to the MAT results for all patients in 2008 (n=818), the number of detected leptospirosis cases increased by 30.4%, from 102 (12.5%) to 133 (16.3%). This study demonstrates a lack of agreement between nucleic acid detection of Leptospira and single-specimen MAT, which may result from the clearance of bacteremia coinciding with the appearance of agglutinating antibodies. A combined testing strategy for acute leptospirosis, including molecular and serologic testing, appears necessary to maximize case detection.

  8. Relationships between Loblolly Pine small clear specimens and Dimension Lumber Tested in Static Bending

    Science.gov (United States)

    Mark Alexander Butler; Joseph Dahlen; Finto Antony; Michael Kane; Thomas L. Eberhardt; Huizhe Jin; Kim Love-Myers; John Paul McTague

    2016-01-01

    Prior to the 1980s, the allowable stresses for lumber in North America were derived from testing of small clear specimens. However, the procedures were changed because these models were found to be inaccurate. Nevertheless, small clear testing continues to be used around the world for allowable stress determinations and in studies that examine forest management impacts...

  9. Method for independent strain and temperature measurement in polymeric tensile test specimen using embedded FBG sensors

    DEFF Research Database (Denmark)

    Pereira, Gilmar Ferreira; McGugan, Malcolm; Mikkelsen, Lars Pilgaard

    2016-01-01

    to calculate independently the strain and temperature are presented in the article, together with a measurement resolution study. This multi-parameter measurement method was applied to an epoxy tensile specimen, tested in a unidirectional tensile test machine with a temperature controlled cabinet. A full......A novel method to obtain independent strain and temperature measurements using embedded Fibre Bragg Grating (FBG) in polymeric tensile test specimens is presented in this paper. The FBG strain and temperature cross-sensitivity was decoupled using two single mode FBG sensors, which were embedded...... of temperature, from 40 C to -10 C. The consistency of the expected theoretical results with the calibration procedure and the experimental validation shows that this proposed method is applicable to measure accurate strain and temperature in polymers during static or fatigue tensile testing. Two different...

  10. Fracture toughness of irradiated Zr-2.5Nb pressure tube from KAPS-2 evaluated using disk compact tension specimens

    International Nuclear Information System (INIS)

    Shah, Priti Kotak; Dubey, J.S.; Balakrishnan, K.S.; Shriwastaw, R.S.; Dhotre, M.P.; Bhandekar, A.; Pandit, K.M.; Anantharaman, S.

    2013-12-01

    The report gives the results of the fracture toughness tests carried out over the range of temperatures on specimens prepared from the irradiated S-07Zr-2.5Nb pressure tube removed from Kakrapar Atomic Power Station-2 (KAPS-2) as a part of materials surveillance programme. The pressure tube had experienced ∼ 8 effective full power years (EFPY) of reactor operation and had hydrogen equivalent (H eq ) content less than 20 ppm along the tube length. The fracture toughness tests have been carried out using 30 mm Disk Compact Tension (DCT) specimens, that were punched out of the irradiated pressure tube. The disk punching was carried out using specially made shielded enclosure and hydraulic press. Fatigue pre-cracking and fracture toughness tests were performed using servo-hydraulic universal testing machine with Direct Current Potential Drop (DCPD) equipment to monitor the crack length. The tests were carried out at different test temperature from ambient to 300℃. The fracture toughness values have been used to estimate the critical pressure for the tube. The fracture properties indicate that such tubes have sufficient toughness to satisfy the Leak-Before-Break (LBB) criterion for in-reactor operation. (author)

  11. The distinct element analysis for swelling pressure test of bentonite. Discussion on the effects of wall friction force and aspect ratio of specimen

    International Nuclear Information System (INIS)

    Shimizu, Hiroyuki; Kikuchi, Hirohito; Fujita, Tomoo; Tanai, Kenji

    2011-10-01

    For geological isolation systems for radioactive waste, bentonite based material is assumed to be used as a buffer material. The swelling characteristics of the bentonite based material are expected to fill up the void space around the radioactive wastes by swelling. In general, swelling characteristics and properties of bentonite are evaluated by the laboratory tests. However, due to the lack of standardization of testing method for bentonite, the accuracy and reproducibility of the testing results are not sufficiently proved. In this study, bentonite swelling pressure test were simulated by newly developed Distinct Element Method (DEM) code, and the effects of wall friction force and aspect ratio of bentonite specimen were discussed. As a result, the followings were found. In the beginning of the swelling pressure test, since swelling occurs only around the fluid injection side of the specimen, wall friction force acts only in the swelling area and the specimen moves to opposite side from fluid injection side. However, when the entire specimen started swelling, displacement of the specimen prevented by the wall friction force, and the specimen is pressed against the pressure measurement side. Then, the swelling pressure measured on the pressure measurement side increases. Such displacement in the specimen is significantly affected by the decreasing of mechanical properties and the difference of saturation in the bentonite specimen during the fluid infiltration. Moreover, when the aspect ratio of the specimen is large, the displacement of the particle in the specimen becomes large and the area on which the wall frictional force acts is also large. Therefore, measured swelling pressure increases more greatly as the aspect ratio of the specimen increases. To contributes to the standardization of laboratory test methods for bentonite, these effects of wall friction force revealed by the DEM simulation should be verified through laboratory experiments. (author)

  12. Instruments for non-destructive evaluation of advanced test reactor inpile tubes

    International Nuclear Information System (INIS)

    Livingston, R.A.; Beller, L.S.; Edgett, S.M.

    1986-01-01

    The Advanced Test Reactor is a 250 MW LWR used primarily for irradiation testing of materials contained in inpile tubes that pass through the reactor core. These tubes provided the high pressure and temperature water environment required for the test specimens. The reactor cooling water surrounding the inpile tubes is at much lower pressure and temperature. The structural integrity of the inpile tubes is monitored by routine surveillance to ensure against unplanned reactor shutdowns to replace defective inpile tubes. The improved instruments developed for inpile tube surveillance include a bore profilometer, ultrasonic flaw detetion system and bore diameter gauges. The design and function of these improved instruments is presented

  13. Post-treatment surveillance testing of patients with colorectal cancer and the association with survival: protocol for a retrospective cohort study of the Surveillance, Epidemiology, and End Results (SEER)-Medicare database.

    Science.gov (United States)

    Hines, Robert B; Jiban, Md Jibanul Haque; Choudhury, Kanak; Loerzel, Victoria; Specogna, Adrian V; Troy, Steven P; Zhang, Shunpu

    2018-04-28

    Although the colorectal cancer (CRC) mortality rate has significantly improved over the past several decades, many patients will have a recurrence following curative treatment. Despite this high risk of recurrence, adherence to CRC surveillance testing guidelines is poor which increases cancer-related morbidity and potentially, mortality. Several randomised controlled trials (RCTs) with varying surveillance strategies have yielded conflicting evidence regarding the survival benefit associated with surveillance testing. However, due to differences in study protocols and limitations of sample size and length of follow-up, the RCT may not be the best study design to evaluate this relationship. An observational comparative effectiveness research study can overcome the sample size/follow-up limitations of RCT designs while assessing real-world variability in receipt of surveillance testing to provide much needed evidence on this important clinical issue. The gap in knowledge that this study will address concerns whether adherence to National Comprehensive Cancer Network CRC surveillance guidelines improves survival. Patients with colon and rectal cancer aged 66-84 years, who have been diagnosed between 2002 and 2008 and have been included in the Surveillance, Epidemiology, and End Results-Medicare database, are eligible for this retrospective cohort study. To minimise bias, patients had to survive at least 12 months following the completion of treatment. Adherence to surveillance testing up to 5 years post-treatment will be assessed in each year of follow-up and overall. Binomial regression will be used to assess the association between patients' characteristics and adherence. Survival analysis will be conducted to assess the association between adherence and 5-year survival. This study was approved by the National Cancer Institute and the Institutional Review Board of the University of Central Florida. The results of this study will be disseminated by publishing in

  14. Investigation of the delay in pressure vessel embrittlement specimen analysis for the Oak Ridge National Laboratory High Flux Isotope Reactor

    International Nuclear Information System (INIS)

    Rothrock, J.D.; Hoffman, E.E.; Manthey, G.C.; Sheffey, D.W.

    1987-01-01

    Analysis of the investigative data pertaining to this incident reveals the following conditions as key findings and probable causes: (1) The contractor failed to properly implement the surveillance program for monitoring reactor pressure vessel embrittlement. (2) Contractor and DOE organizations provided less than adequate oversight and independent overview, especially by not requiring operating organizations to provide documented evidence to substantiate claims that there was ''no problem'' with respect to embrittlement. (3) Although the temperature limitation for reactor pressurization identified in the Technical Specifications was never violated, the basis of this safety limitation was violated. (4) The basis for concluding that there would be no embrittlement of the pressure vessel steel over the expected life of the reactor is questionable. (5) The contractor and DOE failed to make the surveillance program visible by incorporating it in the Technical Specifications. (6) The Accident Analysis/Final Safety Analysis Report was never adequately reviewed and updated subsequent to its initial issuance. (7) Surveillance specimen analysis was incomplete and never transmitted to reactor operating personnel in a usable format prior to November 1986. (8) There was extensive delays (many years) in the testing, analysis, and reporting of surveillance program results

  15. Fracture toughness measurements with subsize disk compact specimens

    International Nuclear Information System (INIS)

    Alexander, D.J.

    1992-01-01

    Special fixtures and test methods have been developed for testing small disk compact specimens (12.5 mm diam by 4.6 mm thick). Both unloading compliance and potential drop methods have been used to monitor crack extension during the J-integral resistance (J-R) curve testing. Provisions have been made to allow the necessary probes and instrumentation to be installed remotely using manipulators for testing of irradiated specimens in a hat cell. Laboratory trials showed that both unloading compliance and potential drop gave useful results. Both techniques gave similar data, and predicted the final crack extension within allowable limits. The results from the small disk compact specimens were similar to results from conventional compact specimens 12.7-mm thick. However, the slopes of the J-R curves from the larger specimens were lower, suggesting that the smaller disk compact specimens may have lost some constraint due to their size. The testing shows that it should be possible to generate useful J-R curve fracture toughness data from the small disk compact specimens

  16. Monitoring temporal changes in the specificity of an oral HIV test: a novel application for use in postmarketing surveillance.

    Directory of Open Access Journals (Sweden)

    Joseph R Egger

    Full Text Available BACKGROUND: Postmarketing surveillance is routinely conducted to monitor performance of pharmaceuticals and testing devices in the marketplace. However, these surveillance methods are often done retrospectively and, as a result, are not designed to detect issues with performance in real-time. METHODS AND FINDINGS: Using HIV antibody screening test data from New York City STD clinics, we developed a formal, statistical method of prospectively detecting temporal clusters of poor performance of a screening test. From 2005 to 2008, New York City, as well as other states, observed unexpectedly high false-positive (FP rates in an oral fluid-based rapid test used for screening HIV. We attempted to formally assess whether the performance of this HIV screening test statistically deviated from both local expectation and the manufacturer's claim for the test. Results indicate that there were two significant temporal clusters in the FP rate of the oral HIV test, both of which exceeded the manufacturer's upper limit of the 95% CI for the product. Furthermore, the FP rate of the test varied significantly by both STD clinic and test lot, though not by test operator. CONCLUSIONS: Continuous monitoring of surveillance data has the benefit of providing information regarding test performance, and if conducted in real-time, it can enable programs to examine reasons for poor test performance in close proximity to the occurrence. Techniques used in this study could be a valuable addition for postmarketing surveillance of test performance and may become particularly important with the increase in rapid testing methods.

  17. Integration of HIV testing in tuberculosis drug resistance surveillance in Kazakhstan and Kenya

    NARCIS (Netherlands)

    Klinkenberg, E.; van den Hof, S.; Tursynbayeva, A.; Kipruto, H.; Wahogo, J.; Pak, S.; Kutwa, A.; L'Herminez, R.

    2012-01-01

    In Kenya and Kazakhstan, integration of human immunodeficiency virus (HIV) testing results into the routine surveillance of multidrug-resistant tuberculosis (MDR-TB) proved feasible and useful. The integration process improved overall data quality and data validation capacity, and integrated data

  18. Reliability of 46,XX results on miscarriage specimens: a review of 1,222 first-trimester miscarriage specimens.

    Science.gov (United States)

    Lathi, Ruth B; Gustin, Stephanie L F; Keller, Jennifer; Maisenbacher, Melissa K; Sigurjonsson, Styrmir; Tao, Rosina; Demko, Zach

    2014-01-01

    To examine the rate of maternal contamination in miscarriage specimens. Retrospective review of 1,222 miscarriage specimens submitted for chromosome testing with detection of maternal cell contamination (MCC). Referral centers requesting genetic testing of miscarriage specimens at a single reference laboratory. Women with pregnancy loss who desire complete chromosome analysis of the pregnancy tissue. Analysis of miscarriage specimens using single-nucleotide polymorphism (SNP) microarray technology with bioinformatics program to detect maternal cell contamination. Chromosome content of miscarriages and incidence of 46,XX results due to MCC. Of the 1,222 samples analyzed, 592 had numeric chromosomal abnormalities, and 630 were normal 46,XX or 46,XY (456 and 187, respectively). In 269 of the 46,XX specimens, MCC with no embryonic component was found. With the exclusion of maternal 46,XX results, the chromosomal abnormality rate increased from 48% to 62%, and the ratio for XX to XY results dropped from 2.6 to 1.0. Over half of the normal 46,XX results in miscarriage specimens were due to MCC. The use of SNPs in MCC testing allows for precise identification of chromosomal abnormalities in miscarriage as well as MCC, improving the accuracy of products of conception testing. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  19. The installation and performance test of the surveillance system for DUPIC facility

    International Nuclear Information System (INIS)

    Kim, Dong Young; Kim, Ho Dong; Cha, Hong Ryul

    2000-07-01

    We have developed the real time surveillance system, named by DSSS, for DUPIC test facility. The system acquires data from He-3 neutron monitors(DSNM) and CCD cameras to automatically diagnose the transportation status of nuclear material. This technical report shortly illustrates important features of hardware and software of the system

  20. The installation and performance test of the surveillance system for DUPIC facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Young; Kim, Ho Dong; Cha, Hong Ryul

    2000-07-01

    We have developed the real time surveillance system, named by DSSS, for DUPIC test facility. The system acquires data from He-3 neutron monitors(DSNM) and CCD cameras to automatically diagnose the transportation status of nuclear material. This technical report shortly illustrates important features of hardware and software of the system.

  1. Sentinel surveillance of HIV-1 transmitted drug resistance, acute infection and recent infection.

    Directory of Open Access Journals (Sweden)

    Hong-Ha M Truong

    Full Text Available HIV-1 acute infection, recent infection and transmitted drug resistance screening was integrated into voluntary HIV counseling and testing (VCT services to enhance the existing surveillance program in San Francisco. This study describes newly-diagnosed HIV cases and characterizes correlates associated with infection.A consecutive sample of persons presenting for HIV VCT at the municipal sexually transmitted infections (STI clinic from 2004 to 2006 (N = 9,868 were evaluated by standard enzyme-linked immunoassays (EIA. HIV antibody-positive specimens were characterized as recent infections using a less-sensitive EIA. HIV-RNA pooled testing was performed on HIV antibody-negative specimens to identify acute infections. HIV antibody-positive and acute infection specimens were evaluated for drug resistance by sequence analysis. Multivariable logistic regression was performed to evaluate associations. The 380 newly-diagnosed HIV cases included 29 acute infections, 128 recent infections, and 47 drug-resistant cases, with no significant increases or decreases in prevalence over the three years studied. HIV-1 transmitted drug resistance prevalence was 11.0% in 2004, 13.4% in 2005 and 14.9% in 2006 (p = 0.36. Resistance to non-nucleoside reverse transcriptase inhibitors (NNRTI was the most common pattern detected, present in 28 cases of resistance (59.6%. Among MSM, recent infection was associated with amphetamine use (AOR = 2.67; p<0.001, unprotected anal intercourse (AOR = 2.27; p<0.001, sex with a known HIV-infected partner (AOR = 1.64; p = 0.02, and history of gonorrhea (AOR = 1.62; p = 0.03.New HIV diagnoses, recent infections, acute infections and transmitted drug resistance prevalence remained stable between 2004 and 2006. Resistance to NNRTI comprised more than half of the drug-resistant cases, a worrisome finding given its role as the backbone of first-line antiretroviral therapy in San Francisco as well as worldwide. The integration of HIV-1 drug

  2. Extension and Verification of the Cross-Section Library for the VVER-1000 Surveillance Specimen Region

    International Nuclear Information System (INIS)

    Kirilova, D.; Belousov, S.; Ilieva, K.

    2011-01-01

    The objective of this work is a generation of new version of the BGL multigroup cross-section to extend the region of its applicability. The existing library version is problem oriented for VVER-1000 type of reactors and was generated by collapsing of the VITAMIN-B6 problem independent cross-section fine-group library applying the VVER-1000 reactor middle plane spectrum in cylindrical geometry. The new version BGLex additionally contains cross-sections averaged on the corresponding spectra of the surveillance specimen's (SS) region for VVER-1000 type of reactors. Comparative analysis of the neutron spectra for different one-dimensional geometry models that could be applied for the cross-section collapsing using the software package SCALE, showed a high sensitivity of the results to the geometry model. That is why a neutron importance assessment was done for the SS region using the adjoint solution calculated by the two-dimensional code DORT and problem-independent library VITAMIN-B6. The one-dimensional geometry model applied to the cross-section collapsing were determined by the material limits above the reactor core in axial direction z as for every material a homogenization in radial direction was done. The material homogenization in radial direction was done by material weighing taking into account the adjoint solution as well as the neutron source. The one-dimensional geometry model comprising the homogenized weighed materials was applied for the cross-section generation of the fine-group library VITAMIN-B6 to the broad-group structure of BGL library. The new version BGLex was extended with cross-sections for the SS region. Verification and validation of the new version BGLex is forthcoming. It includes comparison between the calculated results with the new version BGLex and the libraries BGL and VITAMIN-B6 and comparison with experimental results. (author)

  3. Extension and Verification of the Cross-Section Library for the VVER- 1000 Surveillance Specimen Region

    International Nuclear Information System (INIS)

    Kirilova, D.; Belousov, S.; Ilieva, K.

    2011-01-01

    The objective of this work is a generation of new version of the BGL multigroup cross-section to extend the region of its applicability. The existing library version is problem oriented for VVER-1000 type of reactors and was generated by collapsing of the VITAMIN-B6 problem independent cross-section fine-group library applying the VVER-1000 reactor middle plane spectrum in cylindrical geometry. The new version BGLex additionally contains cross-sections averaged on the corresponding spectra of the surveillance specimen's (SS) region for VVER-1000 type of reactors. Comparative analysis of the neutron spectra for different one-dimensional geometry models that could be applied for the cross-section collapsing using the software package SCALE, showed a high sensitivity of the results to the geometry model. That is why a neutron importance assessment was done for the SS region using the adjoint solution calculated by the two-dimensional code DORT and problem-independent library VITAMIN-B6. The one-dimensional geometry model applied to the cross-section collapsing were determined by the material limits above the reactor core in axial direction z as for every material a homogenization in radial direction was done. The material homogenization in radial direction was done by material weighing taking into account the adjoint solution as well as the neutron source. The one-dimensional geometry model comprising the homogenized weighed materials was applied for the cross-section generation of the fine-group library VITAMIN-B6 to the broad-group structure of BGL library. The new version BGLex was extended with cross-sections for the SS region. Verification and validation of the new version BGLex is forthcoming. It includes comparison between the calculated results with the new version BGLex and the libraries BGL and VITAMIN-B6 and comparison with experimental results. (author)

  4. Strengthening Acute Flaccid Paralysis Surveillance through the Village Polio Volunteers Program in Somalia.

    Science.gov (United States)

    Mbaeyi, Chukwuma; Mohamed, Abdinoor; Owino, Brian Ogola; Mengistu, Kumlachew F; Ehrhardt, Derek; Elsayed, Eltayeb Ahmed

    2018-03-02

    Surveillance for cases of acute flaccid paralysis (AFP) is a key strategy adopted for the eradication of polio. Detection of poliovirus circulation is often predicated on the ability to identify AFP cases and test their stool specimens for poliovirus infection in a timely manner. The Village Polio Volunteers (VPV) program was established in 2013 in a bid to strengthen polio eradication activities in Somalia, including AFP surveillance, given the country's vulnerability to polio outbreaks. To assess the impact of the VPV program on AFP surveillance, we determined case counts, case-reporting sources, and non-polio AFP rates in the years before and after program introduction, i.e., 2011-2016. We also compared the stool adequacy and timeliness of cases reported by VPVs to those reported by other sources. In the years following program introduction, VPVs accounted for a high proportion of AFP cases reported in Somalia. AFP case counts rose from 148 cases in 2012, the year before program introduction, to 279 cases in 2015, during which VPVs accounted for 40% of reported cases. Further, the non-polio AFP rate improved from 2.8 cases in 2012 to 4.8 cases per 100,000 persons Somalia, similar community-based programs could play a crucial role in enhancing surveillance activities in countries with limited healthcare infrastructure.

  5. Technique for the residual life assessment of high temperature components based on creep-rupture testing on welded miniature specimens

    Energy Technology Data Exchange (ETDEWEB)

    Garzillo, A.; Guardamagna, C.; Moscotti, L.; Ranzani, L. [Ente Nazionale per l`Energia Elettrica, Milan (Italy)

    1995-06-01

    Following the present trend in the development of advanced methodologies for residual life assessment of high temperature components operating in power plants, particularly in non destructive methods, a testing technique has been set up at ENEL-CRAM based on creep-rupture testa in an argon on welded miniature specimens. Five experimental systems for creep-rupture tests in an argon atmosphere have been set up which include high accuracy systems, vacuum chambers and exrwnsometer devices. With the aim of establishing and validating the suitability of the experimental methodology, creep-rupture and interrupted creep testing programmes have been performed on miniature specimens (2 mm diameter and 10 mm gauge lenght). On the basis of experience gathered by various European research laboratories, a miniature specimen construction procedure has been developed using a laser welding technique for joining threaded heads to sample material. Low alloy ferritic steels, such as virgin 2.25CrlMo, 0.5Cr 0.5Mo 0.25V, and IN 738 superalloy miniature specimens have been investigated and the results, compared with those from standard specimens, show a regular trend in deformation vs time. Additional efforts to provide guidelines for material sampling from each plant component will be required in order to reduce uncertainties in residual life prediction.

  6. ASTM international symposium on small specimen test techniques and their applications to pressure vessel annealing and plant life extension

    International Nuclear Information System (INIS)

    Garner, F.A.; Hamilton, M.L.; Heinisch, H.L.; Kumar, A.S.

    1992-01-01

    Miniature sheet-type tensile specimens are currently being used in a variety of radiation damage studies conducted in a number of different reactors. Although these specimens are very small, they have proven successful in addressing issues encountered in both thermal reactors and anticipated fusion reactors. This paper reviews the results of a number of recent studies that illustrate the range of applicability of these small specimens. When combined with other types of specimens and other types of measurements made prior to tensile testing, miniature tensile specimens have been found to serve as very useful tools for application to both fundamental studies and alloy screening studies

  7. Assessment of the stability of DNA in specimens collected under conditions for drug testing-A pilot study.

    Science.gov (United States)

    White, Robert M; Mitchell, John M; Hart, E Dale; Evans, Amy; Meaders, Meredith; Norsworthy, Sarah E; Hayes, Eugene D; Flegel, Ron; Maha, George C; Shaffer, Megan D; Hall, Erin M; Rogers, Kelley

    2018-02-01

    For forensic biological sample collections, the specimen donor is linked solidly to his or her specimen through a chain of custody (CoC) sometimes referenced as a chain of evidence. Rarely, a donor may deny that a urine or oral fluid (OF) specimen is his or her specimen even with a patent CoC. The goal of this pilot study was to determine the potential effects of short-term storage on the quality and quantity of DNA in both types of specimen under conditions that may be encountered with employment-related drug testing specimens. Fresh urine and freshly collected oral fluid all produced complete STR profiles. For the "pad" type OF collectors, acceptable DNA was extractable both from the buffer/preservative and the pad. Although fresh urine and OF produced complete STR profiles, partial profiles were obtained after storage for most samples. An exception was the DNA in the Quantisal OF collector, from which a complete profile was obtained for both freshly collected OF and stored OF. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. An innovative HIV testing service using the internet: Anonymous urine delivery testing service at drugstores in Beijing, China.

    Science.gov (United States)

    He, Xiaoxia; Liu, Guowu; Xia, Dongyan; Feng, Xia; Lv, Yi; Cheng, Huanyi; Wang, Yuehua; Lu, Hongyan; Jiang, Yan

    2018-01-01

    Innovative human immunodeficiency virus (HIV) testing services will be needed to achieve the first 90 (90% of HIV-positive persons aware of their infection status) of the 90-90-90 target in China. Here, we describe an internet-based urine delivery testing service delivered through three pilot drugstores in Beijing that send specimens to a designated laboratory for HIV. From May 2016 to January 2017, we provided 500 HIV urine-testing service packs for display at the drugstores, and a total of 430 (86.0%) urine specimens were mailed back. All of the 430 urine specimens were of good quality and were tested. 70 urine specimens were HIV positive, showing a 16.3% (70/430) positivity rate. A total of 94.3% (66/70) of the HIV-positive participants obtained their test results through the internet, and 69.7% (46/66) of these participants received follow-up care. A total of 40 out of 46 (87.0%) participants agreed to have their results confirmed by a blood test, and 39 out of 40 (97.5%) participants were confirmed as HIV-1 positive, including two individuals that were previously diagnosed. Lastly, 28 out of 37 (75.7%) of the study participants were referred to the hospital and provided free antiviral treatment. Our data indicate that this innovative HIV testing service is effective and play an important role in HIV testing and surveillance.

  9. Emergency Diesel Generation System Surveillance Test Policy Optimization Through Genetic Algorithms Using Non-Periodic Intervention Frequencies and Seasonal Constraints

    International Nuclear Information System (INIS)

    Lapa, Celso M.F.; Pereira, Claudio M.N.A.; Frutuoso e Melo, P.F.

    2002-01-01

    Nuclear standby safety systems must frequently, be submitted to periodic surveillance tests. The main reason is to detect, as soon as possible, the occurrence of unrevealed failure states. Such interventions may, however, affect the overall system availability due to component outages. Besides, as the components are demanded, deterioration by aging may occur, penalizing again the system performance. By these reasons, planning a good surveillance test policy implies in a trade-off between gains and overheads due to the surveillance test interventions. In order maximize the systems average availability during a given period of time, it has recently been developed a non-periodic surveillance test optimization methodology based on genetic algorithms (GA). The fact of allowing non-periodic tests turns the solution space much more flexible and schedules can be better adjusted, providing gains in the overall system average availability, when compared to those obtained by an optimized periodic tests scheme. The optimization problem becomes, however, more complex. Hence, the use of a powerful optimization technique, such as GAs, is required. Some particular features of certain systems can turn it advisable to introduce other specific constraints in the optimization problem. The Emergency Diesel Generation System (EDGS) of a Nuclear Power Plant (N-PP) is a good example for demonstrating the introduction of seasonal constraints in the optimization problem. This system is responsible for power supply during an external blackout. Therefore, it is desirable during periods of high blackout probability to maintain the system availability as high as possible. Previous applications have demonstrated the robustness and effectiveness of the methodology. However, no seasonal constraints have ever been imposed. This work aims at investigating the application of such methodology in the Angra-II Brazilian NPP EDGS surveillance test policy optimization, considering the blackout probability

  10. Special fracture mechanics specimens for multilayer plastic pipes testing

    Czech Academy of Sciences Publication Activity Database

    Hutař, Pavel; Šestáková, Lucie; Knésl, Zdeněk; Nezbedová, E.; Náhlík, Luboš

    2009-01-01

    Roč. 28, č. 8 (2009), s. 785-792 ISSN 0142-9418 R&D Projects: GA ČR GA106/09/0279; GA ČR GC101/09/J027 Institutional research plan: CEZ:AV0Z20410507 Keywords : Multilayer plastic pipes * C-type specimen * K-calibration * Fracture toughness * Slow crack growth * Non-homogenous specimens Subject RIV: JL - Material s Fatigue, Friction Mechanics Impact factor: 1.667, year: 2009

  11. Design, Fabrication and Test Report on a Verification Capsule (05M-06K) for the Control of a Neutron Irradiation Fluence of Specimens in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Choo, K. N.; Kim, B. G.; Kang, Y. H.; Cho, M. S.; Son, J. M.; Shin, Y. T.; Park, S. J.; Choi, M. H.; Lee, D. S.

    2007-02-15

    As a part of a project for a capsule development and utilization for an irradiation test, a verification capsule (05M-06K) was designed, fabricated and tested for the development of new instrumented capsule technology for a more precise control of the irradiation fluence of a specimen, irrespective of the reactor operation condition. The basic structure of the 05M-06K capsule was based on the 04M-22K mock-up capsule which was successfully designed and out-pile tested to confirm the various key technologies necessary for the fluence control of a specimen. 21 square and round shaped specimens made of STS 304 were inserted into the capsule. The capsule was constructed in 5 stages with specimens and an independent electric heater at each stage. Each of the five specimens which were accommodated in the 1st stage (top) of the capsule can be taken out of the HANARO core during a normal reactor operation. The specimen is extracted by a specimen extraction mechanism using a steel wire. During the out-pile test, the temperatures of the specimens were measured by 12 thermocouples installed in the capsule. The capsule was successfully out-pile tested in a single channel test loop. The obtained results will be used for a safety evaluation of the new irradiation capsule for controlling the irradiation fluence of specimens in HANARO.

  12. Computer-aided, single-specimen controlled bending test for fracture-kinetics measurement in ceramics

    International Nuclear Information System (INIS)

    Borovik, V.G.; Chushko, V.M.; Kovalev, S.P.

    1995-01-01

    Fracture testing of ceramics by using controlled crack growth is proposed to allow study of crack-kinetics behavior under a given loading history. A computer-aided, real-time data acquisition system improves the quality of crack-growth parameters obtained in a simple, single-specimen bend test. Several ceramic materials were tested in the present study: aluminum nitride as a linear-elastic material; and alumina and yttria-stabilized zirconia, both representative of ceramics with microstructure-dependent nonlinear fracture properties. Ambiguities in the crack-growth diagrams are discussed to show the importance of accounting for crack-growth history in correctly describing nonequilibrium fracture behavior

  13. Fracture toughness measurements with subsize disk compact specimens

    International Nuclear Information System (INIS)

    Alexander, D.J.

    1992-01-01

    Special fixtures and test methods are necessary to facilitate the fracture toughness testing of small disk compact specimens of irradiated candidate materials for first-wall fusion applications. New methods have been developed for both the unloading compliance and potential drop techniques of monitoring crack growth. Provisions have been made to allow the necessary probes and instrumentation to be installed remotely using manipulators for testing of irradiated specimens in a hot cell. Laboratory trials showed that both unloading compliance and potential drop gave useful results. Both techniques gave similar data, and predicted the final crack extension within allowable limits. The results from the small disk compact specimens were similar to results from conventional compact specimen 12.7 mm thick. However, the slopes of the J-R curves from the larger specimens were lower, suggesting that the smaller disk compact specimens may have lost some constraint due to their size. The testing shows that it should be possible to generate useful J-R curve fracture toughness data from the small disk compact specimens

  14. Characterization of test specimens produced in reduced size for X-ray microtomography (µ-CT tests

    Directory of Open Access Journals (Sweden)

    E. E. BERNARDES

    Full Text Available Abstract The need to use reduced sample sizes, in order to attain improved spatial resolution in (µ-CT tests applied in Portland cement composites, makes researchers perform the fractionation of materials to obtain samples with dimensions compatible with the capacity of the scanning equipment, which might cause alterations in the microstructure under analysis. Therefore, a test specimen (TS with dimensions compatible with the scanning capacity of a microtomography system that operates with an X-ray tube and voltage ranging from 20 to 100 kV was proposed. Axial compression strength tests were made and their total porosity was assessed by an apparent density and solid fraction density ratio, which were obtained by means of mercury and helium pycnometry and µ-CT technique, respectively. The adoption of that TS has shown to be viable for providing a sample with a higher level of representation.

  15. Enzymatic detection of formalin-fixed museum specimens for DNA analysis and enzymatic maceration of formalin-fixed specimens

    DEFF Research Database (Denmark)

    Sørensen, Margrethe; Redsted Rasmussen, Arne; Simonsen, Kim Pilkjær

    2016-01-01

    % ethanol. The method was subsequently tested on wild-living preserved specimens and an archived specimen. The protease enzyme used was SavinaseH 16 L, Type EX from Novozymes A/S. The enzymatic screening test demands only simple laboratory equipment. The method is useful for natural history collections...

  16. The feasibility of small size specimens for testing of environmentally assisted cracking of irradiated materials and of materials under irradiation in reactor core

    International Nuclear Information System (INIS)

    Toivonen, A.; Moilanen, P.; Pyykkoenen, M.; Taehtinen, S.; Rintamaa, R.; Saario, T.

    1998-01-01

    Environmentally assisted cracking (EAC) of core materials has become an increasingly important issue of downtime and maintenance costs in nuclear power plants. Small size specimens are necessary in stress corrosion testing of irradiated materials because of difficulties in handling high dose rate materials and because of restricted availability of the materials. The drawback of using small size specimens is that in some cases they do not fulfil the requirements of the relevant testing standards. Recently VTT has developed J-R testing with irradiated and non-irradiated sub size 3 PB specimens, both in inert and in LWR environments. Also, a new materials testing system which will enable simultaneous multiple specimen testing both in laboratory conditions and in operating reactor core is under development. The new testing system will utilize Charpy and sub size 3 PB specimens. The feasibility study of the system has been carried out using different materials. Fracture resistance curves of a Cu-Zr-Cr alloy are shown to be independent of the specimen geometry and size, to some extent. Results gained from tests in simulated boiling water reactor (BWR) water are presented for sensitized SIS 2333 stainless steel. The experimental results indicate that the size of the plastic zone or stress triaxiality must be further studied although no significant effect on the environmentally assisted crack growth rate was observed. (orig.)

  17. The feasibility of small size specimens for testing of environmentally assisted cracking of irradiated materials and of materials under irradiation in reactor core

    Energy Technology Data Exchange (ETDEWEB)

    Toivonen, A.; Moilanen, P.; Pyykkoenen, M.; Taehtinen, S.; Rintamaa, R.; Saario, T. [Valtion Teknillinen Tutkimuskeskus, Espoo (Finland)

    1998-11-01

    Environmentally assisted cracking (EAC) of core materials has become an increasingly important issue of downtime and maintenance costs in nuclear power plants. Small size specimens are necessary in stress corrosion testing of irradiated materials because of difficulties in handling high dose rate materials and because of restricted availability of the materials. The drawback of using small size specimens is that in some cases they do not fulfil the requirements of the relevant testing standards. Recently VTT has developed J-R testing with irradiated and non-irradiated sub size 3 PB specimens, both in inert and in LWR environments. Also, a new materials testing system which will enable simultaneous multiple specimen testing both in laboratory conditions and in operating reactor core is under development. The new testing system will utilize Charpy and sub size 3 PB specimens. The feasibility study of the system has been carried out using different materials. Fracture resistance curves of a Cu-Zr-Cr alloy are shown to be independent of the specimen geometry and size, to some extent. Results gained from tests in simulated boiling water reactor (BWR) water are presented for sensitized SIS 2333 stainless steel. The experimental results indicate that the size of the plastic zone or stress triaxiality must be further studied although no significant effect on the environmentally assisted crack growth rate was observed. (orig.)

  18. Quantitative sensing of corroded steel rebar embedded in cement mortar specimens using ultrasonic testing

    Science.gov (United States)

    Owusu Twumasi, Jones; Le, Viet; Tang, Qixiang; Yu, Tzuyang

    2016-04-01

    Corrosion of steel reinforcing bars (rebars) is the primary cause for the deterioration of reinforced concrete structures. Traditional corrosion monitoring methods such as half-cell potential and linear polarization resistance can only detect the presence of corrosion but cannot quantify it. This study presents an experimental investigation of quantifying degree of corrosion of steel rebar inside cement mortar specimens using ultrasonic testing (UT). A UT device with two 54 kHz transducers was used to measure ultrasonic pulse velocity (UPV) of cement mortar, uncorroded and corroded reinforced cement mortar specimens, utilizing the direct transmission method. The results obtained from the study show that UPV decreases linearly with increase in degree of corrosion and corrosion-induced cracks (surface cracks). With respect to quantifying the degree of corrosion, a model was developed by simultaneously fitting UPV and surface crack width measurements to a two-parameter linear model. The proposed model can be used for predicting the degree of corrosion of steel rebar embedded in cement mortar under similar conditions used in this study up to 3.03%. Furthermore, the modeling approach can be applied to corroded reinforced concrete specimens with additional modification. The findings from this study show that UT has the potential of quantifying the degree of corrosion inside reinforced cement mortar specimens.

  19. Replacement/Refurbishment of JSC/NASA POD Specimens

    Science.gov (United States)

    Castner, Willard L.

    2010-01-01

    The NASA Special NDE certification process requires demonstration of NDE capability by test per NASA-STD-5009. This test is performed with fatigue cracked specimens containing very small cracks. The certification test results are usually based on binomial statistics and must meet a 90/95 Probability of Detection (POD). The assumption is that fatigue cracks are tightly closed, difficult to detect, and inspectors and processes passing such a test are well qualified for inspecting NASA fracture critical hardware. The JSC NDE laboratory has what may be the largest inventory that exists of such fatigue cracked NDE demonstration specimens. These specimens were produced by the hundreds in the late 1980s and early 1990s. None have been produced since that time and the condition and usability of the specimens are questionable.

  20. The 5th surveillance testing for Kori unit 1 reactor vessel materials

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwun Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-08-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 5th surveillance testing was performed primarily by Korea Atomic Energy Research Institute and Westinhouse corporation partially involved in testing and calculation data evaluation in order to obtain reliable test result. Fast neutron fluences for capsule V, T, S, R and P were 5.087E+18, 1.115E+19, 1.228E+19, 2.988E+19, and 3.938E+19n/cm2, respectively. The bias factor, the ratio of calculation/measurement, was 0.940 for the 1st through 5th testing and the calculational uncertainty, 7% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.9846E+19n/cm{sup 2} based on the end of 17th fuel cycle and it was predicted that the fluences of vessel inside surface at 24, 32, 40 and 48EFPY would reach 3.0593E+19, 4.0695E+19, 5.0797E+19 and 6.0900E+19n/cm{sup 2} based on the current calculation. PTS analysis for Kori unit 1 showed that 27.93EFPY was the threshold value for 300 deg F requirement. 71 refs., 33 figs., 52 tabs. (Author)

  1. Multicenter evaluation of resistance patterns of Klebsiella pneumoniae, Escherichia coli, Salmonella spp and Shigella spp isolated from clinical specimens in Brazil: RESISTNET surveillance program

    Directory of Open Access Journals (Sweden)

    Carmen Paz Oplustil

    Full Text Available Surveillance programs are essential to detect the increase of antimicrobial resistance, and several different programs are being conducted in many countries. The RESISTNET is a surveillance program for bacterial resistance against several antimicrobial agents initiated in 1998 among Latin American countries. In Brazil, several centers were invited to join this surveillance and a total of 11 centers (6 from São Paulo and 5 from other states participated in the study. All results were analyzed using the WHONET program. A total of 894 Escherichia coli, 386 Klebsiella pneumoniae, 70 Shigella spp and 57 Salmonella spp strains were analyzed in this study from April, 1998, to April, 1999. Susceptibility testing was performed by the disk diffusion method using NCCLS 1998 guidelines for several different drugs. For all strains, imipenem was the most effective drug (100% of the strains were susceptible. Klebsiella pneumoniae presented a high resistance rate to ampicillin (96.4%. The rate of probable ESBL producers among K. pneumoniae strains was 36.3%, most of them being isolated from catheters (58.8%. Among all Escherichia coli strains analyzed, the highest resistance rate was found for trimethoprim/sulfamethoxazole (46.9% and the majority of the resistant strains were isolated from urine samples (47.8%. Among Salmonella spp, the resistance rates were low for all antibiotics tested. For Shigella spp strains there was a high resistance to trimethoprim/sulfamethoxazole (80.0%. No resistance to ceftriaxone was observed in these strains. Surveillance of antimicrobial resistance is critical for the successful management of infectious diseases. The results of this survey show significant resistance rates among these bacteria which are responsible for several types of human infections.

  2. Genotyping using whole-genome sequencing is a realistic alternative to surveillance based on phenotypic antimicrobial susceptibility testing

    DEFF Research Database (Denmark)

    Zankari, Ea; Hasman, Henrik; Kaas, Rolf Sommer

    2013-01-01

    -genome sequencing (WGS) may soon be within reach even for routine surveillance and clinical diagnostics. The aim of this study was to evaluate WGS as a routine tool for surveillance of antimicrobial resistance compared with current phenotypic procedures. Methods: Antimicrobial susceptibility tests were performed...... to the categorizing of isolates as resistant and 2569 as susceptible. Seven cases of disagreement between tested and predicted susceptibility were observed, six of which were related to spectinomycin resistance in Escherichia coli. Correlation between MLST type and resistance profiles was only observed in Salmonella...

  3. Final Report: Posttest Analysis of Omega II Optical Specimens

    International Nuclear Information System (INIS)

    Newlander, C D; Fisher, J H

    2007-01-01

    Preliminary posttest analyses have been completed on optical specimens exposed during the Omega II test series conducted on 14 July 2006. The Omega Facility, located at the Laboratory for Laser Energetics (LLE) at the University of Rochester was used to produce X-ray environments through the interaction of intense pulsed laser radiation upon germanium-loaded silica aerogels. The optical specimen testing was supported by GH Systems through experiment design, pre- and post-test analyses, specimen acquisition, and overall technical experience. The test specimens were fabricated and characterized by Surface Optics Corporation (SOC), San Diego, CA and were simple protected gold coatings on silica substrates. Six test specimens were exposed, five filtered with thin beryllium foil filters, and one unfiltered which was exposed directly to the raw environment. The experimental objectives were: (1) demonstrate that tests of optical specimens could be performed at the Omega facility; (2) evaluate the use and survivability of beryllium foil filters as a function of thickness; (3) obtain damage data on optical specimens which ranged from no damage to damage; (4) correlate existing thermal response models with the damage data; (5) evaluate the use of the direct raw environment upon the specimen response and the ability/desirability to conduct sensitive optical specimen tests using the raw environment; and (6) initiate the development of a protocol for performing optical coatings/mirror tests. This report documents the activities performed by GH Systems in evaluating and using the environments provided by LLNL, the PUFFTFT analyses performed using those environments, and the calculated results compared to the observed and measured posttest data

  4. Environmental-surveillance report for the Nevada Test Site (January 1982 through December 1982)

    International Nuclear Information System (INIS)

    Scoggins, W.A.

    1983-06-01

    This report documents the environmental surveillance program at the Nevada Test Site as conducted from January 1982 through December 1982. The results and evaluations of measurements of radioactivity in air and water, and of direct gamma radiation exposure rates are presented. Relevancy to DOE concentration guides (CG's) is established

  5. Service-cycle component-feature specimen TMF testing of steam turbine rotor steels

    Energy Technology Data Exchange (ETDEWEB)

    Radosavljevic, M.; Holdsworth, S.R. [Eidgenoessische Materialpruefungs- und Forschungsanstalt, Duebendorf (Switzerland); Mazza, E. [Eidgenoessische Materialpruefungs- und Forschungsanstalt, Duebendorf (Switzerland); Eidgenoessische Technische Hochschule (ETH), Zurich (Switzerland); Grossmann, P.; Ripamonti, L. [ALSTOM Power (Switzerland) Ltd., Baden (Switzerland)

    2010-07-01

    This paper reviews the methodology adopted in a Swiss Research Collaboration to devise a component-feature representative specimen geometry and the TMF cycle parameters necessary to closely simulate arduous steam turbine operating duty. Implementation of these service-like experimental conditions provides a practical indication of the effectiveness of deformation and crack initiation endurance predictions. Comprehensive post test inspection provides evidence to demonstrate the physical realism of the laboratory simulations in terms of the creep-fatigue damage generated during the benchmark tests. Mechanical response results and physical damage observations are presented and their practical implications discussed for the example of a 2%CrMoNiWV rotor service cycle. (orig.)

  6. Instrumentation of a Charpy-pendulum. Additional data obtained from it and its application to nuclear reactor pressure vessels surveillance programs

    International Nuclear Information System (INIS)

    Chomik, Enrique P.; Dhers, Horacio; Iorio, Antonio F.; Ciriani, Dario F.

    1999-01-01

    Charpy test gives information about a material dynamic fracture behavior. In a plain Charpy test, this information is the absorbed energy during fracture of the specimen, lateral deformation and the percentage of ductile fracture of the specimen. These parameters can then be used for the determination of the material response to a dynamic applied load, and are used at present to determine the brittle-ductile transition temperature of a material. However, there is a lot of additional information that can be obtained from a Charpy test, which is vital for the case of surveillance programs of nuclear power plants, where it is necessary to get the most available information from the specimens to be tested, because each one of them was irradiated for many years under temperature and neutronic flux conditions similar to that of the internal surface of the reactor pressure vessel, which converts these specimens in unique and very expensive ones. This additional information can be obtained from the curve that determines the evolution of the applied force to the specimen throughout the time involved in its fracture. It was possible to instrument a Charpy pendulum at a fraction of the cost necessary to buy an instrumentation package like the ones available in the market, and since the instrumentation equipment obtained is easy to transport. It has the additional advantage that can be used to instrument any other pendulum replacing only the hammer of the pendulum with a instrumented one for that pendulum. (author)

  7. Plane strain fracture toughness tests on 2.4 and 3.9-inch-thick maraging steel specimens at various yield strength levels.

    Science.gov (United States)

    Fisher, D. M.; Repko, A. J.

    1972-01-01

    Tests of bend and compact specimens were conducted according to ASTM Tentative Method E 399-70T on a 200 grade maraging steel over a range of yield strengths from 123 to 234 ksi. The toughness of any given yield strength level was greater for the overaged condition than for the underaged. Some results which met the specimen size requirements of the method were distinctly lower than corresponding results from larger specimens. Inconsistencies in both validation and invalidation of results by the requirement for linearity of the test record were also noted.

  8. Development of fatigue life evaluation method using small specimen

    International Nuclear Information System (INIS)

    Nogami, Shuhei; Nishimura, Arata; Wakai, Eichi; Tanigawa, Hiroyasu; Itoh, Takamoto; Hasegawa, Akira

    2013-01-01

    For developing the fatigue life evaluation method using small specimen, the effect of specimen size and shape on the fatigue life of the reduced activation ferritic/martensitic steels (F82H-IEA, F82H-BA07 and JLF-1) was investigated by the fatigue test at room temperature in air using round-bar and hourglass specimens with various specimen sizes (test section diameter: 0.85–10 mm). The round-bar specimen showed no specimen size and no specimen shape effects on the fatigue life, whereas the hourglass specimen showed no specimen size effect and obvious specimen shape effect on it. The shorter fatigue life of the hourglass specimen observed under low strain ranges could be attributed to the shorter micro-crack initiation life induced by the stress concentration dependent on the specimen shape. On the basis of this study, the small round-bar specimen was an acceptable candidate for evaluating the fatigue life using small specimen

  9. Development of small specimen test techniques. Development of a remote controlled small punch testing apparatus

    International Nuclear Information System (INIS)

    Ohmi, Masao; Saito, Junichi; Ooka, Norikazu; Jitsukawa, Shiro; Hishinuma, Akimichi; Umino, Akira.

    1997-01-01

    An accelerator-driven deuterium-lithium (d-Li) stripping reaction-type neutron source, such as the International Fusion Materials Irradiation Facility (IFMIF) planned by the International Energy Agency is recognized as one of the most promising facility to obtain test environments of high-energy neutrons for fusion reactor materials development. The limitation on the available irradiation volume of the irradiation facility requires the development of the small specimen test techniques (SSTT). Application of SSTT to evaluate the degradation of various components in the light water reactor for the life extension is expected to be also quite beneficial. A remote-controlled testing machine for the Small Punch (SP) and miniaturized tensile tests was developed at the hot laboratory of the Japan Materials Testing Reactor (JMTR). The machine is designed for testing at temperatures ranging between 93 and 1,123 K to evaluate the temperature dependence of the strength of materials including the embrittlement at low temperatures and the softening at elevated temperatures. The tests are performed in a vacuum or in an inert gas environment. The machine has been installed in a hot cell and is being used for the round robin test program of the SP test method. The round robin test program is planned to identify the capability of the test method and to establish a standard test procedure. The configuration and the specifications of the test machine are introduced and the results of the SP tests are also shown. (author)

  10. Standard Test Method for Application and Analysis of Helium Accumulation Fluence Monitors for Reactor Vessel Surveillance, E706 (IIIC)

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This test method describes the concept and use of helium accumulation for neutron fluence dosimetry for reactor vessel surveillance. Although this test method is directed toward applications in vessel surveillance, the concepts and techniques are equally applicable to the general field of neutron dosimetry. The various applications of this test method for reactor vessel surveillance are as follows: 1.1.1 Helium accumulation fluence monitor (HAFM) capsules, 1.1.2 Unencapsulated, or cadmium or gadolinium covered, radiometric monitors (RM) and HAFM wires for helium analysis, 1.1.3 Charpy test block samples for helium accumulation, and 1.1.4 Reactor vessel (RV) wall samples for helium accumulation. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Resurgence of Diphtheria in North Kerala, India, 2016: Laboratory Supported Case-Based Surveillance Outcomes

    Directory of Open Access Journals (Sweden)

    Lucky Sangal

    2017-08-01

    Full Text Available IntroductionAs part of national program, laboratory supported vaccine preventable diseases surveillance was initiated in Kerala in 2015. Mechanisms have been strengthened for case investigation, reporting, and data management. Specimens collected and sent to state and reference laboratories for confirmation and molecular surveillance. The major objective of this study is to understand the epidemiological information generated through surveillance system and its utilization for action.MethodsSurveillance data captured from reporting register, case investigation forms, and laboratory reports was analyzed. Cases were allotted unique ID and no personal identifying information was used for analysis. Throat swabs were collected from investigated cases as part of surveillance system. All Corynebacterium diphtheriae isolates were confirmed with standard biochemical tests, ELEK’s test, and real-time PCR. Isolates were characterized using whole genome-based multi locus sequence typing method. Case investigation forms and laboratory results were recorded electronically. Public health response by government was also reviewed.ResultsA total of 533 cases were identified in 11 districts of Kerala in 2016, of which 92% occurred in 3 districts of north Kerala; Malappuram, Kozhikode, and Kannur. Almost 79% cases occurred in >10 years age group. In <18 years age group, 62% were male while in ≥18 years, 69% were females. In <10 years age group, 31% children had received three doses of diphtheria vaccine, whereas in ≥10 years, 3% cases had received all doses. Fifteen toxigenic C. diphtheriae isolates represented 6 novel sequence types (STs (ST-405, ST-408, ST-466, ST-468, ST-469, and ST-470. Other STs observed are ST-50, ST-295, and ST-377.ConclusionDiphtheria being an emerging pathogen, establishing quality surveillance for providing real-time information on disease occurrence and mortality is imperative. The epidemiological data thus generated was

  12. Malaria Surveillance - United States, 2014.

    Science.gov (United States)

    Mace, Kimberly E; Arguin, Paul M

    2017-05-26

    . Less than 1.0% of patients were infected with two species. The infecting species was unreported or undetermined in 11.7% of cases. CDC provided diagnostic assistance for 14.2% of confirmed cases and tested 12.0% of P. falciparum specimens for antimalarial resistance markers. Of patients who reported purpose of travel, 57.5% were visiting friends and relatives (VFR). Among U.S. residents for whom information on chemoprophylaxis use and travel region was known, 7.8% reported that they initiated and adhered to a chemoprophylaxis drug regimen recommended by CDC for the regions to which they had traveled. Thirty-two cases were among pregnant women, none of whom had adhered to chemoprophylaxis. Among all reported cases, 17.0% were classified as severe illness, and five persons with malaria died. CDC received 137 P. falciparum-positive samples for the detection of antimalarial resistance markers (although some loci for chloroquine and mefloquine were untestable for up to nine samples). Of the 137 samples tested, 131 (95.6%) had genetic polymorphisms associated with pyrimethamine drug resistance, 96 (70.0%) with sulfadoxine resistance, 77 (57.5%) with chloroquine resistance, three (2.3%) with mefloquine drug resistance, one (html). Malaria infections can be fatal if not diagnosed and treated promptly with antimalarial medications appropriate for the patient's age and medical history, likely country of malaria acquisition, and previous use of antimalarial chemoprophylaxis. Recent molecular laboratory advances have enabled CDC to identify and conduct molecular surveillance of antimalarial drug resistance markers (https://www.cdc.gov/malaria/features/ars.html) and improve the ability of CDC to track, guide treatment, and manage drug resistance in malaria parasites both domestically and globally. For this effort to be successful, specimens should be submitted for all cases diagnosed in the United States. Clinicians should consult CDC Guidelines for Treatment of Malaria in the

  13. Environmental surveillance report for the Nevada Test Site (January 1980-December 1980)

    International Nuclear Information System (INIS)

    Scoggins, W.A.

    1981-01-01

    Results are presented for the environmental surveillance program at the Nevada Test Site as conducted by the Department of Energy (DOE) onsite radiological safety contractor from January 1980 through December 1980. The results and evaluations of measurements of radioactivity in air and water, and of direct gamma radiation exposure rates are presented. Relevancy to DOE concentration guides (CG'S) is established

  14. Enhanced passive bat rabies surveillance in indigenous bat species from Germany--a retrospective study.

    Directory of Open Access Journals (Sweden)

    Juliane Schatz

    2014-05-01

    Full Text Available In Germany, rabies in bats is a notifiable zoonotic disease, which is caused by European bat lyssaviruses type 1 and 2 (EBLV-1 and 2, and the recently discovered new lyssavirus species Bokeloh bat lyssavirus (BBLV. As the understanding of bat rabies in insectivorous bat species is limited, in addition to routine bat rabies diagnosis, an enhanced passive surveillance study, i.e. the retrospective investigation of dead bats that had not been tested for rabies, was initiated in 1998 to study the distribution, abundance and epidemiology of lyssavirus infections in bats from Germany. A total number of 5478 individuals representing 21 bat species within two families were included in this study. The Noctule bat (Nyctalus noctula and the Common pipistrelle (Pipistrellus pipistrellus represented the most specimens submitted. Of all investigated bats, 1.17% tested positive for lyssaviruses using the fluorescent antibody test (FAT. The vast majority of positive cases was identified as EBLV-1, predominately associated with the Serotine bat (Eptesicus serotinus. However, rabies cases in other species, i.e. Nathusius' pipistrelle bat (Pipistrellus nathusii, P. pipistrellus and Brown long-eared bat (Plecotus auritus were also characterized as EBLV-1. In contrast, EBLV-2 was isolated from three Daubenton's bats (Myotis daubentonii. These three cases contribute significantly to the understanding of EBLV-2 infections in Germany as only one case had been reported prior to this study. This enhanced passive surveillance indicated that besides known reservoir species, further bat species are affected by lyssavirus infections. Given the increasing diversity of lyssaviruses and bats as reservoir host species worldwide, lyssavirus positive specimens, i.e. both bat and virus need to be confirmed by molecular techniques.

  15. Enhanced Passive Bat Rabies Surveillance in Indigenous Bat Species from Germany - A Retrospective Study

    Science.gov (United States)

    Auer, Ernst; Goharriz, Hooman; Harbusch, Christine; Johnson, Nicholas; Kaipf, Ingrid; Mettenleiter, Thomas Christoph; Mühldorfer, Kristin; Mühle, Ralf-Udo; Ohlendorf, Bernd; Pott-Dörfer, Bärbel; Prüger, Julia; Ali, Hanan Sheikh; Stiefel, Dagmar; Teubner, Jens; Ulrich, Rainer Günter; Wibbelt, Gudrun; Müller, Thomas

    2014-01-01

    In Germany, rabies in bats is a notifiable zoonotic disease, which is caused by European bat lyssaviruses type 1 and 2 (EBLV-1 and 2), and the recently discovered new lyssavirus species Bokeloh bat lyssavirus (BBLV). As the understanding of bat rabies in insectivorous bat species is limited, in addition to routine bat rabies diagnosis, an enhanced passive surveillance study, i.e. the retrospective investigation of dead bats that had not been tested for rabies, was initiated in 1998 to study the distribution, abundance and epidemiology of lyssavirus infections in bats from Germany. A total number of 5478 individuals representing 21 bat species within two families were included in this study. The Noctule bat (Nyctalus noctula) and the Common pipistrelle (Pipistrellus pipistrellus) represented the most specimens submitted. Of all investigated bats, 1.17% tested positive for lyssaviruses using the fluorescent antibody test (FAT). The vast majority of positive cases was identified as EBLV-1, predominately associated with the Serotine bat (Eptesicus serotinus). However, rabies cases in other species, i.e. Nathusius' pipistrelle bat (Pipistrellus nathusii), P. pipistrellus and Brown long-eared bat (Plecotus auritus) were also characterized as EBLV-1. In contrast, EBLV-2 was isolated from three Daubenton's bats (Myotis daubentonii). These three cases contribute significantly to the understanding of EBLV-2 infections in Germany as only one case had been reported prior to this study. This enhanced passive surveillance indicated that besides known reservoir species, further bat species are affected by lyssavirus infections. Given the increasing diversity of lyssaviruses and bats as reservoir host species worldwide, lyssavirus positive specimens, i.e. both bat and virus need to be confirmed by molecular techniques. PMID:24784117

  16. High Incidence of Mammalian Orthoreovirus Identified by Environmental Surveillance in Taiwan.

    Directory of Open Access Journals (Sweden)

    Matthew C Y Lim

    Full Text Available Wild poliovirus (WPV persists in diverse locales worldwide, spreading outward from endemic areas. In response to the international threat of WPV transmission and changes in the national vaccination policy, we established an environmental surveillance system to monitor the circulation of wild and vaccine-related poliovirus in Taiwan. From July 2012 to December 2013, we collected sewage specimens every month from 10 sewage treatment plants located throughout Taiwan. The specimens were concentrated by the two-phase separation method and then inoculated into L20B, RD, and A549 cells for virus isolation. Viral isolates were identified and serotyped by immunofluorescence assay or molecular analysis. A total of 300 sewage samples were collected, and the results showed 163 samples (54.3% were positive for virus, and 268 isolates were identified. Among these, 75 samples (25% were positive for enterovirus (EV, but no poliovirus was found. In addition, 92 isolates were identified as enteroviruses and the most common serotypes were coxsackievirus B4, coxsackievirus B3, and coxsackievirus B2. Interestingly, 102 (34% and 82 (27.3% specimens were positive for mammalian orthoreovirus (MRV and adenovirus, respectively. This study confirmed that sewage surveillance can be a useful additional modality for monitoring the possible presence of wild-type or vaccine-derived poliovirus in wastewater, and can indicate the current types of viruses circulating in the population. Furthermore, since MRV was found in children with acute necrotizing encephalopathy and meningitis, the high incidence of MRV detected by environmental surveillance warrants further investigation.

  17. Development of fatigue life evaluation technique using miniature specimen

    International Nuclear Information System (INIS)

    Nogami, Shuhei; Nishimura, Arata; Fujiwara, Masaharu; Hisaka, Tomoaki

    2012-01-01

    To develop the fatigue life evaluation technique using miniature specimen, the investigation of the effect of specimen size and specimen shape on the fatigue life and the development of the fatigue testing machine, especially the extensometer, were carried out. The effect of specimen size on the fatigue life was almost negligible for the round-bar specimens. The shorter fatigue life at relatively low strain range conditions for the hourglass specimen that the standard specimen were observed. Therefore the miniature round-bar specimen was considered to be adequate for the fatigue life evaluation using small specimen. Several types of the extensometer system using a strain gauge and a laser has been developed for realizing the fatigue test of the miniature round-bar specimen at high temperature in vacuum. (author)

  18. Reliability demonstration of imaging surveillance systems

    International Nuclear Information System (INIS)

    Sheridan, T.F.; Henderson, J.T.; MacDiarmid, P.R.

    1979-01-01

    Security surveillance systems which employ closed circuit television are being deployed with increasing frequency for the protection of property and other valuable assets. A need exists to demonstrate the reliability of such systems before their installation to assure that the deployed systems will operate when needed with only the scheduled amount of maintenance and support costs. An approach to the reliability demonstration of imaging surveillance systems which employ closed circuit television is described. Failure definitions based on industry television standards and imaging alarm assessment criteria for surveillance systems are discussed. Test methods which allow 24 hour a day operation without the need for numerous test scenarios, test personnel and elaborate test facilities are presented. Existing reliability demonstration standards are shown to apply which obviate the need for elaborate statistical tests. The demonstration methods employed are shown to have applications in other types of imaging surveillance systems besides closed circuit television

  19. Gamma irradiation test report of simulated grout specimens for gas generation/liquid advection

    International Nuclear Information System (INIS)

    Hinman, C.A.

    1994-01-01

    This report presents the results from an irradiation test performed on four specimens of grout that were fabricated from synthetic Double Shell Slurry Feed (DSSF) liquid waste. The objective was to investigate the radiolytic generation of gases and the potential for advective rejection of waste liquids from the grout matrix and to provide experimental information for the validation of the C-Cubed calculated model. It has been demonstrated that a number of gases can be formed within the grout due to radiolytic decomposition of various chemical components that make up the grout. This observation leads to the conjecture that the potential exists for the rejection of a portion of the 60 vol% free liquid from the grout matrix driven by pressurization by these gases. It was found that, for the specimen geometries used in this test series, and for peak radiation dose accumulation rates on the order of 4 to 60 times of the initial rate expected in the grout vaults (300 Rads/hr), no liquid rejection was observed from 2% to 35% of the target exposure expected in the grout vaults (1E+08 Rads). When the irradiation rate exceeded the projected grout vault dose rate by a factor of 200 a small amount of liquid rejection was observed from one of two specimens that had received 20% more than the goal exposure. Because of the differences in the magnitudes of the relative radiation field strengths between this study and an actual grout vault, it is concluded that the potential for liquid rejection by internal gas pressurization from presently configured grout waste forms is very low for the expected conditions

  20. Evaluation and comparison of multiple test methods, including real-time PCR, for Legionella detection in clinical specimens.

    Directory of Open Access Journals (Sweden)

    Adriana Peci

    2016-08-01

    Full Text Available Legionella is a gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture and PCR test methods and to determine if sputum is an alternative to the use of more invasive bronchoalveolar lavage (BAL. Data for this study included specimens tested for Legionella at PHOL from January 1, 2010 to April 30, 2014, as part of routine clinical testing. We found sensitivity of UAT compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV 63.8% and negative predictive value (NPV 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7% and NPV 98.1%. Of 146 patients who had a Legionella positive result by PCR, only 66(45.2% also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%; sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results despite testing methods (Fisher Exact p-values=1.0, for each test. In summary, all test methods have inherent weaknesses in identifying Legionella; thereforemore than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection, and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical, from patients being tested for Legionella.

  1. Standard practice for preparing, cleaning, and evaluating corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This practice covers suggested procedures for preparing bare, solid metal specimens for tests, for removing corrosion products after the test has been completed, and for evaluating the corrosion damage that has occurred. Emphasis is placed on procedures related to the evaluation of corrosion by mass loss and pitting measurements. (Warning—In many cases the corrosion product on the reactive metals titanium and zirconium is a hard and tightly bonded oxide that defies removal by chemical or ordinary mechanical means. In many such cases, corrosion rates are established by mass gain rather than mass loss.) 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see 1 and 7.2.

  2. Application of subsize specimens in nuclear plant life extension

    International Nuclear Information System (INIS)

    Rosinski, S.T.; Kumar, A.S.; Cannon, N.S.; Hamilton, M.L.

    1993-01-01

    The US Department of Energy is sponsoring a research effort through Sandia National Laboratories and the University of Missouri-Rolla to test a correlation for the upper shelf energy (USE) values obtained from the impact testing of subsize Charpy V-notch specimens to those obtained from the testing of full-size samples. The program involves the impact testing of unirradiated and irradiated full-, half-, and third-size Charpy V-notch specimens. To verify the applicability of the correlation on LWR materials, unirradiated and irradiated full-, half-, and third-size Charpy V-notch specimens of a commercial pressure vessel steel (ASTM A533 Grade B) will be tested. The correlation methodology is based on the partitioning of the USE into crack initiation and crack propagation energies. To accomplish this partition, both precracked and notched-only specimens will be used. Whereas the USE of notched-only specimens is the sum of both crack initiation and crack propagation energies, the USE of precracked specimens reflects only the crack propagation component. The difference in the USE of the two types of specimens represents a measure of the crack initiation energy. Normalizing the values of the crack initiation energy to the fracture volume of the sample produces similar values for the full-, half-, and third-size specimens. In addition, the ratios of the USE and the crack propagation energy are also in agreement for full-, half-, and third-size specimens. These two observations will be used to predict the USE of full-size specimens based on subsize USE data. This paper provides details of the program and presents results obtained from the application of the developed correlation methodology to the impact testing of the unirradiated full-, half-, and third-size A533 Grade B Charpy V-notch specimens

  3. Surveillance of Rotavirus Diarrhea in Hasan Sadikin Hospital Bandung

    Directory of Open Access Journals (Sweden)

    Dwi Prasetyo

    2010-12-01

    Full Text Available The diarrhea morbidity in Indonesia has increased, however, all the reports had not been done carefully, so that accurate surveillance are essential for improving quality of morbidity data. To determine the prevalence and clinical manifestations of rotavirus diarrhea and to characterize the circulating rotavirus strains, children below 5 years old who were admitted to Hasan Sadikin Hospital, Bandung because of diarrhea, from January 2006 through March 2007 were enrolled in a surveillance study and had stool specimens tested for the presence of rotavirus using enzyme immunoassay (EIA. The strains of rotavirus were determined using reverse transcriptase-polymerase chain reaction (RT-PCR. Rotavirus were detected in 47.8% analyzed samples (87/184, G and P-genotype of rotavirus were G[1] (37.5% and P[6] (53.5%. Most subjects were males (56%, 6–11 months of age (35%. Most common clinical manifestations besides diarrhea were dehydration (72.7% and vomiting (50%. Subjects with positive rotavirus more common had dehydration (72% vs 28% and vomiting (61% vs 39%. In conclusion, vomiting and dehydration are the prominent clinical manifestations of diarrhea with positive rotavirus infection. G1 and P6 are the most common genotype of rotavirus.

  4. An innovative HIV testing service using the internet: Anonymous urine delivery testing service at drugstores in Beijing, China.

    Directory of Open Access Journals (Sweden)

    Xiaoxia He

    Full Text Available Innovative human immunodeficiency virus (HIV testing services will be needed to achieve the first 90 (90% of HIV-positive persons aware of their infection status of the 90-90-90 target in China. Here, we describe an internet-based urine delivery testing service delivered through three pilot drugstores in Beijing that send specimens to a designated laboratory for HIV. From May 2016 to January 2017, we provided 500 HIV urine-testing service packs for display at the drugstores, and a total of 430 (86.0% urine specimens were mailed back. All of the 430 urine specimens were of good quality and were tested. 70 urine specimens were HIV positive, showing a 16.3% (70/430 positivity rate. A total of 94.3% (66/70 of the HIV-positive participants obtained their test results through the internet, and 69.7% (46/66 of these participants received follow-up care. A total of 40 out of 46 (87.0% participants agreed to have their results confirmed by a blood test, and 39 out of 40 (97.5% participants were confirmed as HIV-1 positive, including two individuals that were previously diagnosed. Lastly, 28 out of 37 (75.7% of the study participants were referred to the hospital and provided free antiviral treatment. Our data indicate that this innovative HIV testing service is effective and play an important role in HIV testing and surveillance.

  5. 46 CFR 57.04-1 - Test specimen requirements and definition of ranges (modifies QW 202, QW 210, QW 451, and QB 202).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Test specimen requirements and definition of ranges... HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING WELDING AND BRAZING Procedure Qualification Range § 57.04-1 Test specimen requirements and definition of ranges (modifies QW 202, QW 210, QW 451, and QB 202...

  6. USFDA-GUIDELINE BASED VALIDATION OF TESTING METHOD FOR RIFAMPICIN IN INDONESIAN SERUM SPECIMEN

    Directory of Open Access Journals (Sweden)

    Tri Joko Raharjo

    2010-06-01

    Full Text Available Regarding a new regulation from Indonesia FDA (Badan POM-RI, all new non patent drugs should show bioequivalence with the originator drug prior to registration. Bioequivalence testing (BE-testing has to be performed to the people that represented of population to which the drug to be administrated. BE testing need a valid bio-analytical method for certain drug target and group of population. This research report specific validation of bio-analysis of Rifampicin in Indonesian serum specimen in order to be used for BE testing. The extraction was performed using acetonitrile while the chromatographic separation was accomplished on a RP 18 column (250 × 4.6 mm i.d., 5 µm, with a mobile phase composed of KH2PO4 10 mM-Acetonitrile (40:60, v/v and UV detection was set at 333 nm. The method shown specificity compared to blank serum specimen with retention time of rifampicin at 2.1 min. Lower limit of quantification (LLOQ was 0.06 µg/mL with dynamic range up to 20 µg/mL (R>0.990. Precision of the method was very good with coefficient of variance (CV 0.58; 7.40 and 5.56% for concentration at 0.06, 5, 15 µg/mL, respectively. Accuracies of the method were 3.22; 1.94; 1.90% for concentration 0.06, 5 and 15 µg/mL respectively. The average recoveries were 97.82, 95.50 and 97.31% for concentration of rifampicin 1, 5 and 5 µg/mL, respectively. The method was also shown reliable result on stability test on freezing-thawing, short-term and long-term stability as well as post preparation stability. Validation result shown that the method was ready to be used for Rifampicin BE testing with Indonesian subject.   Keywords: Rifampicin, Validation, USFDA-Guideline

  7. 49 CFR 40.173 - Who is responsible for paying for the test of a split specimen?

    Science.gov (United States)

    2010-10-01

    ... is responsible for paying for the test of a split specimen? (a) As the employer, you are responsible... 49 Transportation 1 2010-10-01 2010-10-01 false Who is responsible for paying for the test of a.... (b) As the employer, you must not condition your compliance with these requirements on the employee's...

  8. Evaluation and Comparison of Multiple Test Methods, Including Real-time PCR, for Legionella Detection in Clinical Specimens

    Science.gov (United States)

    Peci, Adriana; Winter, Anne-Luise; Gubbay, Jonathan B.

    2016-01-01

    Legionella is a Gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture, and polymerase chain reaction (PCR) test methods and to determine if sputum is an acceptable alternative to the use of more invasive bronchoalveolar lavage (BAL). Data for this study included specimens tested for Legionella at Public Health Ontario Laboratories from 1st January, 2010 to 30th April, 2014, as part of routine clinical testing. We found sensitivity of urinary antigen test (UAT) compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV) 63.8%, and negative predictive value (NPV) 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7%, and NPV 98.1%. Out of 146 patients who had a Legionella-positive result by PCR, only 66 (45.2%) also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%); sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results regardless testing methods (Fisher Exact p-values = 1.0, for each test). In summary, all test methods have inherent weaknesses in identifying Legionella; therefore, more than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical from patients being tested for Legionella. PMID:27630979

  9. Development of European creep crack growth testing code of practice for industrial specimens

    Energy Technology Data Exchange (ETDEWEB)

    Dogan, B.; Nikbin, K. [Imperial College, London (United Kingdom); Petrovski, B. [Technische Univ. Darmstadt (DE). Inst. fuer Werkstoffkunde (IFW)

    2004-07-01

    The integrity and residual life assessment of high temperature components require defects, detected or assumed to exist, through minimum allowable limits of detectable flaws using nondestructive testing methods. It relies on information obtained from the material's mechanical, uniaxial creep, creep crack initiation and growth properties. The information derived from experiments needs to be validated and harmonised following a Code of Practice that data variability between different institutions can be reduced to a minimum. The present paper reports on a Code of Practice (CoP) being prepared within the framework of the partially European Commission funded project CRETE. The novel aspect of the presented CoP is the inclusion of component relevant industrial specimen geometries. It covers testing and analysis of Creep Crack growth (CCG) in metallic materials at elevated temperature using six different cracked geometries that have been validated in. It aims to give advice on testing, measurements and analysis of creep crack growth data for a range of creep brittle to creep ductile materials using component service relevant specimen geometries and sizes. The CoP may be used for material selection criteria and inspection requirements for damage tolerant applications. In quantitative terms, these types of tests can be used to assess the individual and combined effects of metallurgical, fabrication, operating temperature, and loading conditions on creep crack growth life. Further issues will be addressed including material properties, damage and crack growth related constraint effect, stress relaxation and stress-strain fields, residual stresses, partitioning displacement, analysis of elasticcreep, elastic compliance measurements.

  10. Development of European creep crack growth testing code of practice for industrial specimens

    International Nuclear Information System (INIS)

    Dogan, B.; Nikbin, K.; Petrovski, B.

    2004-01-01

    The integrity and residual life assessment of high temperature components require defects, detected or assumed to exist, through minimum allowable limits of detectable flaws using nondestructive testing methods. It relies on information obtained from the material's mechanical, uniaxial creep, creep crack initiation and growth properties. The information derived from experiments needs to be validated and harmonised following a Code of Practice that data variability between different institutions can be reduced to a minimum. The present paper reports on a Code of Practice (CoP) being prepared within the framework of the partially European Commission funded project CRETE. The novel aspect of the presented CoP is the inclusion of component relevant industrial specimen geometries. It covers testing and analysis of Creep Crack growth (CCG) in metallic materials at elevated temperature using six different cracked geometries that have been validated in. It aims to give advice on testing, measurements and analysis of creep crack growth data for a range of creep brittle to creep ductile materials using component service relevant specimen geometries and sizes. The CoP may be used for material selection criteria and inspection requirements for damage tolerant applications. In quantitative terms, these types of tests can be used to assess the individual and combined effects of metallurgical, fabrication, operating temperature, and loading conditions on creep crack growth life. Further issues will be addressed including material properties, damage and crack growth related constraint effect, stress relaxation and stress-strain fields, residual stresses, partitioning displacement, analysis of elastic creep, elastic compliance measurements

  11. External quality assurance of malaria nucleic acid testing for clinical trials and eradication surveillance

    NARCIS (Netherlands)

    Murphy, S.C.; Hermsen, C.C.; Douglas, A.D.; Edwards, N.J.; Petersen, I.; Fahle, G.A.; Adams, M.; Berry, A.A.; Billman, Z.P.; Gilbert, S.C.; Laurens, M.B.; Leroy, O.; Lyke, K.E.; Plowe, C.V.; Seilie, A.M.; Strauss, K.A.; Teelen, K.; Hill, A.V.; Sauerwein, R.W.

    2014-01-01

    Nucleic acid testing (NAT) for malaria parasites is an increasingly recommended diagnostic endpoint in clinical trials of vaccine and drug candidates and is also important in surveillance of malaria control and elimination efforts. A variety of reported NAT assays have been described, yet no formal

  12. Strength Prediction and Failure Modes of Concrete Specimens Subjected to the Split Test

    DEFF Research Database (Denmark)

    Hoang, Linh Cao; Andersen, M.E.; Hansen, N.T.

    2014-01-01

    This paper deals with modelling and test of concrete specimens subjected to the Brazilian split test. Based on the fictitious crack concept, a simple model for the crack propagation process in the splitting plane is developed. From the model, it is possible to determine the distribution of residual...... tensile strength as crack propagation take place. The residual tensile strength is thereafter used in a rigid plastic analysis of the splitting failure. Based on this combined approach, the ultimate load may either be governed by crack propagation or by a plastic failure, which then terminates the crack...

  13. SurePath Specimens Versus ThinPrep Specimen Types on the COBAS 4800 Platform: High-Risk HPV Status and Cytology Correlation in an Ethnically Diverse Bronx Population.

    Science.gov (United States)

    Naeem, R C; Goldstein, D Y; Einstein, Mark H; Ramos Rivera, G; Schlesinger, K; Khader, S N; Suhrland, M; Fox, A S

    2017-08-01

    To compare the cytologic preparations of 130 cervical specimens (from women of various ethnicities at high risk for human papillomavirus [HPV] infection) using the SurePath (SP) collection system with specimens gathered using the ThinPrep (TP) system, as processed on the Cobas 4800 analyzer, to determine which collection method more accurately identifies HPV infection. In our prospective study, specimens were collected from 130 women of various ethnicities residing in or near Bronx County, NY. The SP-collected specimen was first processed for cytologic findings; if clinical HPV testing was requested on that specimen, it was tested using Hybrid Capture II (HC2) methodology. We tested the remnant SP-collected cell concentrate using the Cobas analyzer. Then, the TP-collected and SP-collected specimens were tested in the same run on that analyzer, and the results were compared. We also compared the results with the concurrent cytologic findings. The results were concordant for overall HR-HPV status in 93.8% of cases. Also, a statistically significant lower cycle threshold value was observed with Cobas testing of specimen concentrates tested via the BD SurePath Pap Test (P = .001), suggesting higher sensitivity compared with specimens tested via the ThinPrep Pap Test. Cobas 4800 HPV testing of SP-collected specimen concentrates yields comparable results to TP-collected specimen concentrates. Based on the limited data that we derived, SP collection may be a more favorable methodology than TP collection for HPV testing of individuals at high risk in our ethnically diverse, urban patient population. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  14. Screen-film specimen radiography

    International Nuclear Information System (INIS)

    Shepard, S.J.; Hogan, J.; Schreck, B.

    1990-01-01

    This paper reports on the reproducibility and quality of biopsy specimen radiographs, a unique phototimed cabinet x-ray system is being developed. The system utilizes specially modified Kodal Min-R cassettes and will be compatible with current mammographic films. Tube voltages are in the 14-20-kVp range with 0.1-1.0-second exposure times. A top-hat type compression device is used (1) to compress the specimen to uniform thickness, (2) to measure the specimen thickness and determine optimum kVp, and (3) to superimpose a grid over the specimen for identification of objects of radiographic interest. The phototiming circuit developed specifically for this purpose will be described along with the modified Min-R cassette. Characteristics of the generator and cabinet will also be described. Tests will be performed on phantoms to evaluate the system limitations

  15. Evaluation of the enterovirus laboratory surveillance system in Denmark, 2010 to 2013.

    Science.gov (United States)

    Condell, Orla; Midgley, Sofie; Christiansen, Claus Bohn; Chen, Ming; Chen Nielsen, Xiaohui; Ellermann-Eriksen, Svend; Mølvadgaard, Mette; Schønning, Kristian; Vermedal Hoegh, Silje; Andersen, Peter Henrik; Voldstedlund, Marianne; Fischer, Thea Kølsen

    2016-05-05

    The primary aim of the Danish enterovirus (EV) surveillance system is to document absence of poliovirus infection. The conflict in Syria has left many children unvaccinated and movement from areas with polio cases to Europe calls for increased awareness to detect and respond to virus-transmission in a timely manner. We evaluate the national EV laboratory surveillance, to generate recommendations for system strengthening. The system was analysed for completeness of viral typing analysis and clinical information and timeliness of specimen collection, laboratory results and reporting of clinical information. Of 23,720 specimens screened, 2,202 (9.3%) were EV-positive. Submission of cerebrospinal fluid and faecal specimens from primary diagnostic laboratories was 79.5% complete (845/1,063), and varied by laboratory and patient age. EV genotypes were determined in 68.5% (979/1,430) of laboratory-confirmed cases, clinical information was available for 63.1% (903/1,430). Primary diagnostic results were available after a median of 1.4 days, typing results after 17 days, detailed clinical information after 33 days. The large number of samples typed demonstrated continued monitoring of EV-circulation in Denmark. The system could be strengthened by increasing the collection of supplementary faecal specimens, improving communication with primary diagnostic laboratories, adapting the laboratory typing methodology and collecting clinical information with electronic forms.

  16. AGC-2 Specimen Post Irradiation Data Package Report

    Energy Technology Data Exchange (ETDEWEB)

    Windes, William Enoch [Idaho National Lab. (INL), Idaho Falls, ID (United States); Swank, W. David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rohrbaugh, David T. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Cottle, David L. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-08-01

    This report documents results of the post-irradiation examination material property testing of the creep, control, and piggyback specimens from the irradiation creep capsule Advanced Graphite Creep (AGC)-2 are reported. This is the second of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades. The AGC-2 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 600°C and to a peak dose of 5 dpa (displacements per atom). One-half of the creep specimens were subjected to mechanical stresses (an applied stress of either 13.8, 17.2, or 20.7 MPa) to induce irradiation creep. All post-irradiation testing and measurement results are reported with the exception of the irradiation mechanical strength testing, which is the last destructive testing stage of the irradiation testing program. Material property tests were conducted on specimens from 15 nuclear graphite grades using a similar loading configuration as the first AGC capsule (AGC-1) to provide easy comparison between the two capsules. However, AGC-2 contained an increased number of specimens (i.e., 487 total specimens irradiated) and replaced specimens of the minor grade 2020 with the newer grade 2114. The data reported include specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and volume data necessary to derive density, elastic constants (Young’s modulus, shear modulus, and Poisson’s ratio) from ultrasonic time-of-flight velocity measurements, Young’s modulus from the fundamental frequency of vibration, electrical resistivity, and thermal diffusivity and thermal expansion data from 100–500°C. No data outliers were determined after all measurements were completed. A brief statistical analysis was performed on the irradiated data and a limited comparison between

  17. Standard practice for verification of testing frame and specimen alignment under tensile and compressive axial force application

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 Included in this practice are methods covering the determination of the amount of bending that occurs during the application of tensile and compressive forces to notched and unnotched test specimens in the elastic range and to plastic strains less than 0.002. These methods are particularly applicable to the force application rates normally used for tension testing, creep testing, and uniaxial fatigue testing.

  18. Standard practice for verification of testing frame and specimen alignment under tensile and compressive axial force application

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2014-01-01

    1.1 Included in this practice are methods covering the determination of the amount of bending that occurs during the application of tensile and compressive forces to notched and unnotched test specimens in the elastic range and to plastic strains less than 0.002. These methods are particularly applicable to the force application rates normally used for tension testing, creep testing, and uniaxial fatigue testing.

  19. HIV test offers and acceptance: New York State findings from the behavioral risk factor surveillance system and the National HIV behavioral surveillance, 2011-2012.

    Science.gov (United States)

    John Leung, Shu-Yin; Sinclair, Amber H; Battles, Haven B; Swain, Carol-Ann E; French, Patrick Tyler; Anderson, Bridget J; Sowizral, Mycroft J; Ruberto, Rachael; Brissette, Ian; Lillquist, Patricia; Smith, Lou C

    2015-01-01

    The New York State HIV testing law requires that patients aged 13-64 years be offered HIV testing in health care settings. We investigated the extent to which HIV testing was offered and accepted during the 24 months after law enactment. We added local questions to the Behavioral Risk Factor Surveillance System (BRFSS) and the National HIV Behavioral Surveillance (NHBS) surveys asking respondents aged 18-64 years whether they were offered an HIV test in health care settings, and whether they had accepted testing. Statewide prevalence estimates of test offers and acceptance were obtained from a combined 2011-2012 BRFSS sample (N = 6,223). Local estimates for 2 high-risk populations were obtained from NHBS 2011 men who have sex with men (N = 329) and 2012 injection drug users (N = 188) samples. BRFSS data showed that 73% of New Yorkers received care in any health care setting in the past 12 months, of whom 25% were offered an HIV test. Sixty percent accepted the test when offered. The levels of test offer increased from 20% to 29% over time, whereas acceptance levels decreased from 68% to 53%. NHBS data showed that 81% of men who have sex with men received care, of whom 43% were offered an HIV test. Eighty-eight percent accepted the test when offered. Eighty-five percent of injection drug users received care, of whom 63% were offered an HIV test, and 63% accepted the test when offered. We found evidence of partial and increasing implementation of the HIV testing law. Importantly, these studies demonstrated New Yorkers' willingness to accept an offered HIV test as part of routine care in health care settings.

  20. Environmental surveillance report for the Nevada Test Site (January 1981 through December 1981)

    International Nuclear Information System (INIS)

    Scoggins, W.A.

    1982-05-01

    This report documents the environmental surveillance program at the Nevada Test Site as conducted by the Department of Energy (DOE) onsite radiological safety contractor from January 1981 through December 1981. The results and evaluations of measurements of radioactivity in air and water, and of direct gamma radiation exposure rates are presented. Relevancy to DOE concentration guides (CG'S) is established

  1. An effective surveillance strategy for reactor pressure vessel assessment in the long term operation perspective

    International Nuclear Information System (INIS)

    Chaouadi, R.; Gerard, R.

    2015-01-01

    The reactor pressure vessel (RPV) irradiation embrittlement is monitored by means of surveillance capsules containing the RPV belt-line materials, inserted inside the reactor pressure vessel (RPV) before the start of operation. These capsules are placed at location where they receive a higher neutron flux than the vessel wall, by a factor of the order of 2 to 3. They are regularly retrieved and tested to evaluate the RPV irradiation embrittlement according to specific regulatory procedures and standards, in order to guarantee the safe operation of the RPV throughout its lifetime. These procedures are often relying on empirical but conservative concepts. In parallel, material research reactor (MTR) irradiations are often used to support the surveillance data and to develop a better understanding of irradiation effects, not only qualitatively but also quantitatively. Taking advantage of the increased understanding of irradiation effects, analytical tools were developed to improve the evaluation embrittlement and quality assurance of the RPV embrittlement assessment. In this framework, an alternative but complementary surveillance program assessment was developed in Belgium, the so-called enhanced surveillance, in order to benefit from the latest developments in the area of materials science and irradiation effects. The neutron flux and fracture properties of the surveillance materials can be reliably characterized and correlated to each other using physically-based rather than empirical concepts. The enhanced surveillance approach is complementary to the mandatory regulatory procedure and allows quantifying the conservatism of the regulatory approach. The enhanced surveillance approach that uses the reconstitution technology to fabricate additional small size specimens, appropriate modeling tools and microstructural examination when required, makes it possible to rationalize all available information in a physically-based way

  2. Burden of laboratory-confirmed Campylobacter infections in Guatemala 2008-2012: results from a facility-based surveillance system.

    Science.gov (United States)

    Benoit, Stephen R; Lopez, Beatriz; Arvelo, Wences; Henao, Olga; Parsons, Michele B; Reyes, Lissette; Moir, Juan Carlos; Lindblade, Kim

    2014-03-01

    Campylobacteriosis is one of the leading causes of gastroenteritis worldwide. This study describes the epidemiology of laboratory-confirmed Campylobacter diarrheal infections in two facility-based surveillance sites in Guatemala. Clinical, epidemiologic, and laboratory data were collected on patients presenting with acute diarrhea from select healthcare facilities in the departments of Santa Rosa and Quetzaltenango, Guatemala, from January 2008 through August 2012. Stool specimens were cultured for Campylobacter and antimicrobial susceptibility testing was performed on a subset of isolates. Multidrug resistance (MDR) was defined as resistance to ≥3 antimicrobial classes. Campylobacter was isolated from 306 (6.0%) of 5137 stool specimens collected. For children Guatemala; antimicrobial resistance was high, and treatment regimens in the ambulatory setting which included metronidazole and trimethoprim-sulfamethoxazole and lacked oral rehydration were sub-optimal. Published by Elsevier Ltd.

  3. High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas® CT/NG.

    Science.gov (United States)

    Marlowe, Elizabeth M; Hardy, David; Krevolin, Mark; Gohl, Peter; Bertram, Alexander; Arcenas, Rodney; Seiverth, Britta; Schneider, Tanja; Liesenfeld, Oliver

    2017-09-01

    We compared the analytical and clinical performance of cobas ® CT/NG for use on the Cobas ® 6800/8800 Systems with the Cobas ® 4800 CT/NG Test from urogenital and extragenital specimens in over 12,000 specimens from both male and female subjects in Germany and the United States. The analytical sensitivity was ≤40 EB/ml for Chlamydia trachomatis (CT) and ≤1 CFU/ml for Neisseria gonorrhoeae (NG). Using clinical specimens, the overall percent agreement with the Cobas ® 4800 CT/NG Test was >98.5%. Across urogenital specimens, there were 93 discrepant specimens; 76 (93.8%) of 81 CT discrepant specimens were 6800+/4800- and 10 (83.3%) of 12 NG discrepant specimens were 6800+/4800-. Sequencing verified CT results for 45 (61.6%) of 73 samples positive by 6800 and 1 (20%) of 5 positive by 4800. Similarly, 7 (70.0%) of 10 NG samples positive by 6800 and 1 of 2 positive by 4800 were confirmed by sequencing. Among discrepant extragenital specimens (all 6800+/4800-), 7 (50%) of 14 oropharyngeal and 23 (76.7%) of 30 anorectal CT discordant samples were confirmed as CT positive by sequencing; all 8 anorectal and 20 (90.9%) of 22 oropharyngeal NG discordant results were also confirmed as NG positive. In conclusion, Cobas ® CT/NG for use on the Cobas ® 6800/8800 Systems provides high-throughput automated solutions for sexually transmitted infection (STI) screening programs.

  4. Residual stress state in pipe cut ring specimens for fracture toughness testing

    Energy Technology Data Exchange (ETDEWEB)

    Damjanovic, Darko [J.J. Strossmayer Univ. of Osijek, Slavonski Brod (Croatia). Mechanical Engineering Faculty; Kozak, Drazan [Zagreb Univ. (Croatia). Dept. for Mechanical Design; Marsoner, Stefan [Materials Center, Leoben (Austria).; Gubeljak, Nenad [Maribor Univ. (Slovenia). Chair of Mechanics

    2017-07-01

    Thin-walled pipes are not suitable for measuring fracture toughness parameters of vital importance because longitudinal crack failure is the most common failure mode in pipes. This is due to the impossibility to manufacture standard specimens for measuring fracture toughness, such as SENB or CT specimens, from the thin wall of the pipe. Previous works noticed this problem, but until now, a good and convenient solution has not been found or developed. To overcome this problem, very good alternative solution was proposed, the so-called pipe ring notched bend specimen (PRNB) [1-5]. Until now, only the idealized geometry PRNB specimen is analyzed, i. e., a specimen which is not cut out from an actual pipe but produced from steel plate. Based on that, residual stresses are neglected along with the imperfections in geometry (elliptical and eccentricity). The aim of this research is to estimate the residual stress state(s) in real pipes used in the boiler industry produced by hot rolling technique. These types of pipes are delivered only in normalized condition, but not stress relieved. Therefore, there are residual stresses present due to the manufacturing technique, but also due to uneven cooling after the production process. Within this paper, residual stresses are estimated by three methods: the incremental hole drilling method (IHMD), X-ray diffraction (XRD) and the splitting method (SM). Knowing the residual stress state in the ring specimen, it is possible to assess their impact on fracture toughness measured on the corresponding PRNB specimen(s).

  5. Residual stress state in pipe cut ring specimens for fracture toughness testing

    International Nuclear Information System (INIS)

    Damjanovic, Darko; Kozak, Drazan; Marsoner, Stefan; Gubeljak, Nenad

    2017-01-01

    Thin-walled pipes are not suitable for measuring fracture toughness parameters of vital importance because longitudinal crack failure is the most common failure mode in pipes. This is due to the impossibility to manufacture standard specimens for measuring fracture toughness, such as SENB or CT specimens, from the thin wall of the pipe. Previous works noticed this problem, but until now, a good and convenient solution has not been found or developed. To overcome this problem, very good alternative solution was proposed, the so-called pipe ring notched bend specimen (PRNB) [1-5]. Until now, only the idealized geometry PRNB specimen is analyzed, i. e., a specimen which is not cut out from an actual pipe but produced from steel plate. Based on that, residual stresses are neglected along with the imperfections in geometry (elliptical and eccentricity). The aim of this research is to estimate the residual stress state(s) in real pipes used in the boiler industry produced by hot rolling technique. These types of pipes are delivered only in normalized condition, but not stress relieved. Therefore, there are residual stresses present due to the manufacturing technique, but also due to uneven cooling after the production process. Within this paper, residual stresses are estimated by three methods: the incremental hole drilling method (IHMD), X-ray diffraction (XRD) and the splitting method (SM). Knowing the residual stress state in the ring specimen, it is possible to assess their impact on fracture toughness measured on the corresponding PRNB specimen(s).

  6. Global optimization of maintenance and surveillance testing based on reliability and probabilistic safety assessment. Research project

    International Nuclear Information System (INIS)

    Martorell, S.; Serradell, V.; Munoz, A.; Sanchez, A.

    1997-01-01

    Background, objective, scope, detailed working plan and follow-up and final product of the project ''Global optimization of maintenance and surveillance testing based on reliability and probabilistic safety assessment'' are described

  7. Role of a Surveillance System in the Management of an Outbreak of Dengue in the Mid Hills of Himachal Pradesh, India

    Directory of Open Access Journals (Sweden)

    Ajay Kumar Singh

    2017-11-01

    Full Text Available Introduction: Surveillance systems are instrumental in not only eliciting the impending outbreaks but also for initiation of public health action. Integrated Disease Surveillance Programme (IDSP of India guides in the clinical and laboratory diagnosis of vector borne diseases such as Dengue and its management. Aim: To assess any impending outbreak of Dengue in the region, by using IDSP surveillance data and to assess the need based mitigation measures. Materials and Methods: The routine IDSP surveillance of June 2015 highlighted an impending outbreak of Dengue in Solan district of Himachal Pradesh, India. Spot map was prepared for epidemiological linkage of the sporadic cases being reported. Moreover the retrospective epidemiologic IDSP surveillance data was analysed for finding out any cases of Dengue reported in the past. Clinical case definition of Dengue, formulated by IDSP was adopted. Diagnostic facility was set up. Entomological surveillance was used to calculate House Index, Container Index, Breteau Index. Aedes ageypti mosquito was identified by laboratory techniques. Mitigation activities like sanitation and cleanliness drive, fogging, inter-sectoral meetings and coordination were initiated. Daily surveillance was initiated and data was analysed in Microsoft Office Excel 2010 and Epi Info software version 7.2.0.1. The value of p<0.05 was considered as significant. Results: Based upon data analysis, outbreak of Dengue was declared on 7th September, 2015. A total of 686 probable cases were positive by rapid diagnostic/card tests whereas 57 and 109 patients were positive by NS1Ag and IgM tests. The relation of Dengue with respect to age and sex of the patients was found statistically non-significant with p-values of 2.01 and 3.20 respectively. House Index was higher (37.5% in the industry dominated Nalagarh region. Genus Aedes was identified in three out of 12 mosquito specimens with the help of available mosquito key. Other specimens

  8. Experience gained with the development of a performance test program for the monitoring and surveillance systems in the Embalse nuclear power plant

    International Nuclear Information System (INIS)

    Arestin, M.L.

    1988-01-01

    The monitoring and surveillance system for Embalse nuclear power plant are presented. The reactor, the nuclear fuel management, the equipments from monitoring and surveillance system, the activities developed by the AIEA experts in each mission of this test program and the management of the components for this test program in Argentine are described. (E.G.) [pt

  9. Standard Practice for Recording Data from Atmospheric Corrosion Tests of Metallic-Coated Steel Specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice covers a procedure for recording data of atmospheric corrosion tests of metallic-coated steel specimens. Its objective is the assurance of (1) complete identification of materials before testing, (2) objective reporting of material appearance during visual inspections, and (3) adequate photographic, micrographic, and chemical laboratory examinations at specific stages of deterioration, and at the end of the tests. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. Conclusions regarding fracture mechanics testing and evaluation of small specimens - As evidenced by the finnish contribution to the IAEA CRP3 programme

    Energy Technology Data Exchange (ETDEWEB)

    Wallin, K; Valo, M; Rintamaa, R; Torronen, K [Technical Research Centre of Finland, Espoo (Finland); Ahlstrand, R [Imatran Voima Oy (IVO), Helsinki (Finland)

    1994-12-31

    An extensive mechanical property evaluation has been carried out on various specimens (a Japanese steel plate (JRQ), a French forging material (FFA) and a Japanese forging material (JFL)) in the as-received and irradiated conditions. The mechanical properties measured at different temperatures include Charpy-V notch and instrumented pre-cracked Charpy data and static and dynamic elastic-plastic fracture toughness based on the J-integral, with various specimen size and geometry. Test analysis lead to conclusions regarding the use of small specimen fracture mechanical tests for investigating irradiation effects: CVN{sub pc} and RCT type specimens are suitable for determining the materials fracture toughness even in the ductile/brittle transition region provided the elastic-plastic parameter K{sub JC} is applied together with a statistical size correction. These two specimen types yield equivalent results for the fracture toughness transition shift. Charpy-V appears not to be suitable for estimating the static fracture toughness transition shift. 8 refs., 11 figs.

  11. Use of Reactor Pressure Vessel Surveillance Materials for Extended Life Evaluations Using Power and Test Reactor Irradiations

    International Nuclear Information System (INIS)

    Server, W.L.; Nanstad, R.K.; Odette, G.R.

    2012-01-01

    The most important component in assuring safety of the nuclear power plant is the reactor pressure (RPV). Surveillance programs have been designed to cover the licensed life of operating nuclear RPVs. The original surveillance programs were designed when the licensed life was 40 years. More than one-half of the operating nuclear plants in the USA have an extended license out to 60 years, and there are plans to continue to operate many plants out to 80 years. Therefore, the surveillance programs have had to be adjusted or enhanced to generate key data for 60 years, and now consideration must be given for 80 or more years. To generate the necessary data to assure safe operation out to these extended license lives, test reactor irradiations have been initiated with key RPV and model alloy steels, which include several steels irradiated in the current power reactor surveillance programs out to relatively high fluence levels. These data are crucial in understanding the radiation embrittlement mechanisms and to enable extrapolation of the irradiation effects on mechanical properties for these extended time periods. This paper describes the potential radiation embrittlement mechanisms and effects when assessing much longer operating times and higher neutron fluence levels. Potential methods for adjusting higher neutron flux test reactor data for use in predicting power reactor vessel conditions are discussed. (author)

  12. Surveillance of the environmental radioactivity

    International Nuclear Information System (INIS)

    Schneider, Th.; Gitzinger, C.; Jaunet, P.; Eberbach, F.; Clavel, B.; Hemidy, P.Y.; Perrier, G.; Kiper, Ch.; Peres, J.M.; Josset, M.; Calvez, M.; Leclerc, M.; Leclerc, E.; Aubert, C.; Levelut, M.N.; Debayle, Ch.; Mayer, St.; Renaud, Ph.; Leprieur, F.; Petitfrere, M.; Catelinois, O.; Monfort, M.; Baron, Y.; Target, A.

    2008-01-01

    The objective of these days was to present the organisation of the surveillance of the environmental radioactivity and to allow an experience sharing and a dialog on this subject between the different actors of the radiation protection in france. The different presentations were as follow: evolution and stakes of the surveillance of radioactivity in environment; the part of the European commission, regulatory aspects; the implementation of the surveillance: the case of Germany; Strategy and logic of environmental surveillance around the EDF national centers of energy production; environmental surveillance: F.B.F.C. site of Romans on Isere; steps of the implementation 'analysis for release decree at the F.B.F.C./C.E.R.C.A. laboratory of Romans; I.R.S.N. and the environmental surveillance: situation and perspectives; the part of a non institutional actor, the citizenship surveillance done by A.C.R.O.; harmonization of sampling methods: the results of inter operators G.T. sampling; sustainable observatory of environment: data traceability and samples conservation; inter laboratories tests of radioactivity measurements; national network of environmental radioactivity measurement: laboratories agreements; the networks of environmental radioactivity telemetry: modernization positioning; programme of observation and surveillance of surface environment and installations of the H.A.-M.A.V.L. project (high activity and long life medium activity); Evolution of radionuclides concentration in environment and adaptation of measurements techniques to the surveillance needs; the national network of radioactivity measurement in environment; modes of data restoration of surveillance: the results of the Loire environment pilot action; method of sanitary impacts estimation in the area of ionizing radiations; the radiological impact of atmospheric nuclear tests in French Polynesia; validation of models by the measure; network of measurement and alert management of the atmospheric

  13. Burden of laboratory-confirmed Campylobacter infections in Guatemala 2008–2012: Results from a facility-based surveillance system

    Science.gov (United States)

    Benoit, Stephen R.; Lopez, Beatriz; Arvelo, Wences; Henao, Olga; Parsons, Michele B.; Reyes, Lissette; Moir, Juan Carlos; Lindblade, Kim

    2015-01-01

    Introduction Campylobacteriosis is one of the leading causes of gastroenteritis worldwide. This study describes the epidemiology of laboratory-confirmed Campylobacter diarrheal infections in two facility-based surveillance sites in Guatemala. Methods Clinical, epidemiologic, and laboratory data were collected on patients presenting with acute diarrhea from select healthcare facilities in the departments of Santa Rosa and Quetzaltenango, Guatemala, from January 2008 through August 2012. Stool specimens were cultured for Campylobacter and antimicrobial susceptibility testing was performed on a subset of isolates. Multidrug resistance (MDR) was defined as resistance to ≥3 antimicrobial classes. Results Campylobacter was isolated from 306 (6.0%) of 5137 stool specimens collected. For children Guatemala; antimicrobial resistance was high, and treatment regimens in the ambulatory setting which included metronidazole and trimethoprim-sulfamethoxazole and lacked oral rehydration were sub-optimal. PMID:24534336

  14. The 4th surveillance testing for Kori unit 3 reactor vessel materials

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwun Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2000-10-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 4th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Kori site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Kori unit 3 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules U, V, X and W are 4.983E+18, 1.641E+19, 3.158E+19, and 4.469E+19n/cm{sup 2}, respectively. The bias factor, the ratio of calculation/measurement, was 0.840 for the 1st through 4th testing and the calculational uncertainty, 12% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.362E+19n/cm{sup 2} based on the end of 12th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 3.481E+19, 4.209E+19, 5.144E+19 and 5.974E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Kori unit 3 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 48 refs., 35 figs., 41 tabs. (Author)

  15. Hospital-based Clostridium difficile infection surveillance reveals high proportions of PCR ribotypes 027 and 176 in different areas of Poland, 2011 to 2013.

    Science.gov (United States)

    Pituch, Hanna; Obuch-Woszczatyński, Piotr; Lachowicz, Dominika; Wultańska, Dorota; Karpiński, Paweł; Młynarczyk, Grażyna; van Dorp, Sofie M; Kuijper, Ed J

    2015-01-01

    As part of the European Clostridium difficile infections (CDI) surveillance Network (ECDIS-Net), which aims to build capacity for CDI surveillance in Europe, we constructed a new network of hospital-based laboratories in Poland. We performed a survey in 13 randomly selected hospital-laboratories in different sites of the country to determine their annual CDI incidence rates from 2011 to 2013. Information on C. difficile laboratory diagnostic testing and indications for testing was also collected. Moreover, for 2012 and 2013 respectively, participating hospital-laboratories sent all consecutive isolates from CDI patients between February and March to the Anaerobe Laboratory in Warsaw for further molecular characterisation, including the detection of toxin-encoding genes and polymerase chain reaction (PCR)-ribotyping. Within the network, the mean annual hospital CDI incidence rates were 6.1, 8.6 and 9.6 CDI per 10,000 patient-days in 2011, 2012, and 2013 respectively. Six of the 13 laboratories tested specimens only on the request of a physician, five tested samples of antibiotic-associated diarrhoea or samples from patients who developed diarrhoea more than two days after admission (nosocomial diarrhoea), while two tested all submitted diarrhoeal faecal samples. Most laboratories (9/13) used tests to detect glutamate dehydrogenase and toxin A/B either separately or in combination. In the two periods of molecular surveillance, a total of 166 strains were characterised. Of these, 159 were toxigenic and the majority belonged to two PCR-ribotypes: 027 (n=99; 62%) and the closely related ribotype 176 (n=22; 14%). The annual frequency of PCR-ribotype 027 was not significantly different during the surveillance periods (62.9% in 2012; 61.8% in 2013). Our results indicate that CDIs caused by PCR-ribotype 027 predominate in Polish hospitals participating in the surveillance, with the closely related 176 ribotype being the second most common agent of infection.

  16. Analysis of the necessity for inserting new surveillance capsule into the Kori Unit 1 RPV to monitor material fracture toughness

    International Nuclear Information System (INIS)

    Song, Taek Ho

    2007-01-01

    In association with monitoring of reactor pressure vessel (RPV) fracture toughness, surveillance capsule test specimens have been used to monitor the material property of nuclear reactor vessel. As far as Kori Unit 1 is concerned, 6 capsules were put into the vessel before commercial operation of the plant. Up to now, all the six capsules have been withdrawn to test and monitor the fracture toughness of RPV material. The last capsule has been withdrawn on June this year, and the Kori unit 1 has been shut downed since July 2007 and will be shut downed until December this year for about 6 months, preparing the life extension of the plant to operate the plant 10 more years. With the situation that all the surveillance capsules have been withdrawn, public ask the following question, 'To extend the life of Kori Unit 1 more than 10 years, is it necessary to insert new surveillance capsules into the Kori Unit 1 to monitor RPV material fracture toughness?' In connection with this issue, planning project have been carried out since spring this year. In this paper, it is described that inserting new surveillance capsule into the Kori Unit 1 RPV has some meaning in some public acceptance point of view and is not necessary in material engineering point of view

  17. Predicting crack instability behavior of burst tests from small specimens for irradiated Zr-2.5Nb pressure tubes

    International Nuclear Information System (INIS)

    Davies, P.H.

    1997-01-01

    A scaling approach, based on the deformation J-integral at maximum load obtained from small specimens, is proposed for predicting the crack instability behavior of burst tests on irradiated Zr-2.5Nb pressure tubes. An assessment of this approach is carried out by comparison with other toughness criteria such as the modified J-integral and the plastic work dissipation rate approach. The largest discrepancy between the different parameters occurs for materials of intermediate toughness which exhibit the most stable crack growth and tunnelling up to maximum load. A study of one material of intermediate toughness suggests crack-front tunnelling has a significant influence on the results obtained from the 17-mm-wide specimens. It is shown that for a tube of intermediate toughness the different approaches can significantly underpredict the extent of stable crack growth before instability in a burst test even after correcting for tunnelling. The usefulness of a scaling approach in reducing the discrepancy between the small- and large-scale specimen results for this material is demonstrated

  18. Grips for testing of electrical characteristics of a specimen under a mechanical load

    Science.gov (United States)

    Briggs, Timothy; Loyola, Bryan

    2018-04-24

    Various technologies to facilitate coupled electrical and mechanical measurement of conductive materials are disclosed herein. A gripping device simultaneously holds a specimen in place and causes contact to be made between the specimen and a plurality of electrodes connected to an electrical measuring device. An electrical characteristic of the specimen is then measured while a mechanical load is applied to the specimen, and a relationship between the mechanical load and changes in the electrical characteristic can be identified.

  19. Surveillance of emerging drugs of abuse in Hong Kong: validation of an analytical tool.

    Science.gov (United States)

    Tang, Magdalene H Y; Ching, C K; Tse, M L; Ng, Carol; Lee, Caroline; Chong, Y K; Wong, Watson; Mak, Tony W L

    2015-04-01

    To validate a locally developed chromatography-based method to monitor emerging drugs of abuse whilst performing regular drug testing in abusers. Cross-sectional study. Eleven regional hospitals, seven social service units, and a tertiary level clinical toxicology laboratory in Hong Kong. A total of 972 drug abusers and high-risk individuals were recruited from acute, rehabilitation, and high-risk settings between 1 November 2011 and 31 July 2013. A subset of the participants was of South Asian ethnicity. In total, 2000 urine or hair specimens were collected. Proof of concept that surveillance of emerging drugs of abuse can be performed whilst conducting routine drug of abuse testing in patients. The method was successfully applied to 2000 samples with three emerging drugs of abuse detected in five samples: PMMA (paramethoxymethamphetamine), TFMPP [1-(3-trifluoromethylphenyl)piperazine], and methcathinone. The method also detected conventional drugs of abuse, with codeine, methadone, heroin, methamphetamine, and ketamine being the most frequently detected drugs. Other findings included the observation that South Asians had significantly higher rates of using opiates such as heroin, methadone, and codeine; and that ketamine and cocaine had significantly higher detection rates in acute subjects compared with the rehabilitation population. This locally developed analytical method is a valid tool for simultaneous surveillance of emerging drugs of abuse and routine drug monitoring of patients at minimal additional cost and effort. Continued, proactive surveillance and early identification of emerging drugs will facilitate prompt clinical, social, and legislative management.

  20. Colonic surveillance by CT colonography using axial images only

    International Nuclear Information System (INIS)

    Bruzzi, John F.; Brennan, Darren D.; Fenlon, Helen M.; Moss, Alan C.; MacMathuna, Padraic

    2004-01-01

    Patients at increased risk of colon cancer require strict colon surveillance. Our objective was to establish the efficacy of 2D axial CT colonography as a surveillance test when performed in routine clinical practice. Eighty-two patients at increased risk of colon cancer underwent CT colonography followed by conventional colonoscopy on the same morning. CT colonography studies were performed on a four-ring multidetector CT scanner (100 mAs, 120 kVp, 4 x 2.5 collimation) and were interpreted by two radiologists using 2D axial images only. Results were correlated with findings at colonoscopy. Note was made of subsequent histology reports from polypectomy specimens. A total of 52 polyps were detected at colonoscopy. Using 2D axial images alone, with no recourse to 2D multiplanar or 3D views, the sensitivity of CT colonography was 100, 33 and 19% for polyps larger than 9, 6-9 and smaller than 6 mm, respectively. Per-patient specificities were 98.8, 96 and 81.5%, respectively. Twenty-nine percent of polyps smaller than 1 cm were adenomatous and there were no histological features of severe dysplasia. CT colonography is a useful colon surveillance tool for patients at increased risk of colon cancer. It has a high specificity for identifying patients who should proceed to colonoscopy and polypectomy, while allowing further colon examination to be deferred in patients with normal studies. Using 2D axial images only, CT colonography can be performed as part of the daily CT workload, with a very low rate of referral for unnecessary colonoscopy. (orig.)

  1. Sentinel surveillance for influenza in Senegal, 1996-2009.

    Science.gov (United States)

    Niang, Mbayame Ndiaye; Dosseh, Annick; Ndiaye, Kader; Sagna, Monique; Gregory, Victoria; Goudiaby, Deborah; Hay, Alan; Diop, Ousmane M

    2012-12-15

    Data on influenza in tropical and resource-limited countries are scarce. In this study we present results from 14 years of influenza surveillance in Senegal, one of the few tropical countries in Africa from which longitudinal data are available. From 1996 to 2009, we collected respiratory specimens from outpatients presenting with influenza-like illness at 13 facilities in order to investigate the epidemiology of seasonal influenza and the characteristics of the circulating influenza viruses. Specimens were tested for influenza using viral isolation and/or reverse-transcription polymerase chain reaction (RT-PCR). From 1996 to 2009, specimens were obtained from 9176 patients; 1233 (13%) were influenza-positive by virus isolation and/or RT-PCR. Among positive samples, 958 (77%) were influenza A, 268 (22%) influenza B, and 7 (1%) influenza type C; of influenza A viruses, 619 (65%) were A(H3) and 339 (35%) A(H1), of which 13 (1%) were identified as H1N2. The proportion positive was similar for children 55 years (9%). Although influenza A(H1), A(H3), and B all circulated during most years, influenza A(H3N2) predominated during 9 of the 14 years. Influenza activity consistently peaked during the rainy season (July-September). Phylogenetic analysis showed that viruses circulating in Senegal were similar to contemporary viruses circulating elsewhere in the world. Our data confirm that influenza is prevalent in Senegal, occurs in seasonal epidemics, and contributes to the burden of respiratory diseases in all age groups.

  2. Examination of cadmium safety rod thermal test specimens and failure mechanism evaluation

    International Nuclear Information System (INIS)

    Thomas, J.K.; Peacock, H.B.; Iyer, N.C.

    1992-01-01

    The reactor safety rods may be subjected to high temperatures due to gamma heating after the core coolant level has dropped during the ECS phase of a hypothetical LOCA event. Accordingly, an experimental cadmium safety rod testing subtask was established as part of a task to address the response of reactor core components to this accident. Companion reports describe the experiments and a structural evaluation (finite element analysis) of the safety rod. This report deals primarily with the examination of the test specimens, evaluation of possible failure mechanisms, and confirmatory separate effects experiments. It is concluded that the failures observed in the cadmium safety rod thermal tests which occurred at low temperature (T 800 degrees C) with fast thermal ramp rates are concluded to be mechanical in nature without significant environmental degradation. Based on these tests, tasks were initiated to design and manufacture B 4 C safety rods to replace the cadmium safety rods. The B 4 C safety rods have been manufactured at this time and it is currently planned to charge them to the reactor in the near future. 60 refs

  3. Newly developed non-destructive testing method for evaluation of irradiation brittleness of structural materials using ultrasonic

    International Nuclear Information System (INIS)

    Ishii, Toshimitsu; Ooka, Norikazu; Kato, Yoshiaki; Saito, Junichi; Hoshiya, Taiji; Shibata, Saburo; Kobayashi, Hideo

    1999-01-01

    Surveillance testing is important to evaluate neutron irradiation embrittlement of reactor pressure vessel material for long life operation. An alternative test method for evaluating the irradiation embrittlement of the pressure vessel material will have to be proposed to support the limited number of surveillance test specimens in order to manage the plant life to be extended. In this study, ultrasonic testing for irradiated A533B-1 steel and weld metal was applied to examine material degradation nondestructively. With increasing the shift of Charpy 41 J transition temperature, ultrasonic velocity decreased and attenuation coefficient of ultrasonic wave increased. Especially, the difference of ultrasonic velocity for 5 MHz shear wave between as-received and irradiated material is corresponding to the shift of transition temperature showing material degradation. (author)

  4. Development of a reconstitution system of Charpy probes for the surveillance of vessels in nucleo electric plants

    International Nuclear Information System (INIS)

    Romero C, J.; Hernandez, R.; Fernandez, F.; Gonzalez M, A.

    2007-01-01

    This work describes the development of a welding system, for the rebuilding of halves of Charpy test tubes, the rebuilding consists on welding two implants in those ends of these halves of test tubes, in these welding the main requirement is not to alter the mechanical properties in a minimum volume of 1 cm 3 , the rebuilding is medullary in the surveillance programs of the reactor vessel. In these programs, the mechanical state of the vessel is evaluated, for it there are surveillance capsules with a Charpy witness test tubes series, subjected to a neutron flow similar or bigger to that of the vessel. The objective is to evaluate in advance on the vessel fragilization grade its life design. However the number of capsules with the witness test tubes it is only for the plant design life and at the moment the nucleo electric, negotiates an extension of life of these, until for 20 more years, of there the importance of this material witness's that stores the information of the damage accumulated by the neutron flow. This material requires to be taken advantage it after being rehearsed and the normative one settles down as obligatory to qualify the rebuilding process with all the requirements settled down in the ASTM Designation: E 1253-99 'Standard Guide for Reconstitution of irradiated Charpy-Sized Specimens', to obtain other reconstituted Charpy test tubes that are again introduced in the reactor. When being reconstituted the halves of the original test tubes it is obtained double reconstituted Charpy test tubes. Half of the test tubes they are used in the surveillance program of the vessel, with the surpluses test tubes, it can determine the fracture toughness, property of the material used in the extension methodology of life of vessel. (Author)

  5. Effects of crack front curvature on J–R curve testing using clamped SE(T) specimens of homogeneous materials

    International Nuclear Information System (INIS)

    Huang, Yifan; Zhou, Wenxing

    2015-01-01

    Three-dimensional (3D) finite element analyses (FEA) of clamped single-edge tension (SE(T)) specimens are performed to investigate the impact of the crack front curvature on the elastic compliance, compliance rotation correction factor and average J-integral evaluated over the crack front. Specimens with six average crack lengths (i.e. a_a_v_e/W = 0.2–0.7) and three thickness-to-width ratios (i.e. B/W = 0.5, 1 and 2) are analyzed. The curved crack front is assumed to be bowed symmetrically and characterized by a power-law expression with a wide range of curvatures. Several crack front straightness requirements for SE(B) and C(T) specimens specified in BS7448, ISO and ASTM E1820 standards are reviewed. Based on results of the numerical investigation, new crack front straightness criteria for the SE(T) specimen are proposed in the context of the nine-point measurement by using as a criterion that the errors in the estimated compliance and average J values should be no more than five percent. The proposed criteria depend on both a_a_v_e/W and B/W, and are more advantageous than those specified in the BS, ISO and ASTM standards in terms of controlling the differences in J and compliance between the specimens with curved and straight crack fronts. - Highlights: • Investigate the impacts of crack front curvature on the compliance, rotation correction factor and J for SE(T) specimens. • Validate the applicabilities of crack front straightness criteria specified in the seven test standards on SE(T) specimens. • Recommend new crack front straightness criteria for the SE(T) specimen.

  6. Fracture toughness measurements with subsize disk compact specimens

    International Nuclear Information System (INIS)

    Alexander, D.J.

    1994-01-01

    Special fixtures and test methods have been developed for testing small disk compact specimens (1.25 mm diam by 4.6 mm thick). Specimens of European type 316L austenitic stainless steel were irradiated to damage levels of about 3 dpa at nominal irradiation temperatures of either 90 or 250 C and tested over a temperature range from 20 to 250 C. Results show that irradiation to this dose level at these temperatures reduces the fracture toughness but the toughness remains quite high. The toughness decreases as the test temperature increases. Irradiation at 250 C is more damaging than at 90 C, causing larger decreases in the fracture toughness. The testing shows that it is possible to generate useful fracture toughness data with a small disk compact specimens

  7. Development of specimen size and test rate effects on the J-integral upper transition behavior of A533B steel

    International Nuclear Information System (INIS)

    Joyce, James A.

    1988-01-01

    During the past three years a test method has been developed for dynamic testing of fracture mechanics specimens which is specifically designed for application to the upper transition temperature range. The method uses drop tower loading rates of 2.5 m/sec and obtains a J IC or a J-R curve using an analytical key curve approach verified by initial and final crack length measurements obtained from the fracture surface. A J-R curve is obtained from each specimen and contains crack growth corrections so that it is directly comparable with static results obtained in accordance with the ASTM E1152 J-R curve test method. The test procedure has been applied to A106 steel, A533B steel and US Navy HY80 and HY100 steels at temperatures from -200F to 150F. Standard 1T three point bend specimens were used for the A533B and the HY100 steel. Static test results have shown that the J at cleavage initiation (which is presently an unstandardized quantity) is specimen a/W independent throughout the ductile to brittle transition but of course demonstrates considerable statistical scatter in the vicinity of the ductile upper shelf. Dynamic J-R tests have shown an increase in J IC with test rate for most, but not for all, materials. Separation of J into elastic and plastic components shows that the elastic J component increases with test rate in a fashion consistent with the materials tensile sensitivity to test rate but the plastic J component decreases with test rate - an apparent visco-plastic phenomena. For A106 steel the plastic J decrease exceeds the elastic J increase and the upper shelf toughness falls - while the other materials have demonstrated a relatively larger increase in the elastic J component and a smaller decrease in the plastic J component giving an overall increase in upper shelf toughness. Separation of the J integral into elastic and plastic components has demonstrated that J EL is specimen scale and geometry dependent while J PL is relatively scale and geometry

  8. 2007 Nevada Test Site Annual Illness and Injury Surveillance Report

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Office of Health, Safety and Health, Office of Health and Safety, Office of Illness and Injury Prevention Programs

    2009-06-30

    The U.S. Department of Energy’s (DOE) commitment to assuring the health and safety of its workers includes the conduct of epidemiologic surveillance activities that provide an early warning system for health problems among workers. The Illness and Injury Surveillance Program monitors illnesses and health conditions that result in an absence of workdays, occupational injuries and illnesses, and disabilities and deaths among current workers.

  9. 2006 Nevada Test Site Annual Illness and Injury Surveillance Report

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Office of Health, Safety and Health, Office of Health and Safety, Office of Illness and Injury Prevention Programs

    2008-04-24

    The U.S. Department of Energy’s (DOE) commitment to assuring the health and safety of its workers includes the conduct of illness and injury surveillance activities that provide an early warning system to detect health problems among workers. The Illness and Injury Surveillance Program monitors illnesses and health conditions that result in an absence, occupational injuries and illnesses, and disabilities and deaths among current workers.

  10. 2008 Nevada Test Site Annual Illness and Injury Surveillance Report

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, Office of Health, Safety and Health, Office of Health and Safety, Office of Illness and Injury Prevention Programs

    2009-10-05

    The U.S. Department of Energy’s (DOE) commitment to assuring the health and safety of its workers includes the conduct of epidemiologic surveillance activities that provide an early warning system for health problems among workers. The Illness and Injury Surveillance Program monitors illnesses and health conditions that result in an absence of workdays, occupational injuries and illnesses, and disabilities and deaths among current workers.

  11. An automated tensile machine for small specimens heavily neutron irradiated in FFTF/MOTA

    International Nuclear Information System (INIS)

    Kohyama, Akira; Sato, Shinji; Hamada, Kenichi

    1993-01-01

    The objective of this work is to develop a fully automated tensile machine for post-irradiation examination (PIE) of Fast Flux Test Facility (FFTF)/Materials Open Test Assembly (MOTA) irradiated miniature tension specimens. The anticipated merit of the automated tensile machine is to reduce damage to specimens during specimen handling for PIE and to reduce exposure to radioactive specimens. This machine is designed for testing at elevated temperatures, up to 873 K, in a vacuum or in an inert gas environment. Twelve specimen assemblies are placed in the vacuum chamber that can be tested successively in a fully automated manner. A unique automated tensile machine for the PIE of FFTF/MOTA irradiated specimens, the Monbusho Automated Tensile Machine (MATRON) consists of a test frame with controlling units and an automated specimen-loading apparatus. The qualification of the test frame has been completed, and the results have satisfied the machine specifications. The capabilities of producing creep and relaxation data have been demonstrated for Cu, Al, 316SS, and ferritic steels. The specimen holders for the three-point bending test and the small bulge test (small punch test; SP test) were also designed and produced

  12. Determination of a cohesive law for delamination modelling - Accounting for variation in crack opening and stress state across the test specimen width

    DEFF Research Database (Denmark)

    Joki, R. K.; Grytten, F.; Hayman, Brian

    2016-01-01

    by differentiating the fracture resistance with respect to opening displacement at the initial location of the crack tip, measured at the specimen edge. 2) Extend the bridging law to a cohesive law by accounting for crack tip fracture energy. 3) Fine-tune the cohesive law through an iterative modelling approach so......The cohesive law for Mode I delamination in glass fibre Non-Crimped Fabric reinforced vinylester is determined for use in finite element models. The cohesive law is derived from a delamination test based on DCB specimens loaded with pure bending moments taking into account the presence of large...... that the changing state of stress and deformation across the width of the test specimen is taken into account. The changing state of stress and deformation across the specimen width is shown to be significant for small openings (small fracture process zone size). This will also be important for the initial part...

  13. Use of miniature tensile specimen and video extensometer for measurement of mechanical properties

    International Nuclear Information System (INIS)

    Kumar, Kundan; Pooleery, Arun; Madhusoodanan, K.

    2014-08-01

    Miniaturisation of the tensile test specimen below the sub-size level poses various challenges, such as conformity of specimen to various acceptance criteria as per standard test specimen, aspect ratio, minimum number of grains required in a gauge cross-section, fabrication for uniformity in metrological values, etc. Apart from these, measurement of strain over a very limited available space on the test specimen is another practical challenge. Despite these limitations, miniature specimen testing is increasingly being used worldwide these days. The driving forces behind increasing use of miniature test techniques are new material development, assuring fitness of component after in-service-inspection, low dose of radiation exposure due to smaller dimensions of test specimens etc. However, the evaluation of mechanical properties from a miniature tensile test has a greater advantage over the other miniature novel test techniques, such as small punch test, ABI, miniature fatigue and impact tests etc., as it is a direct method of measurement of mechanical properties. This report covers various aspects of miniature tensile test methodologies, which include geometrical design of specimen having gauge length of 3-5 mm, fabrication, development of special fixtures for gripping the test specimens, and use of optical method for strain measurement. The geometrical design of the specimen and its behaviour over application of tensile load has been established using FEM analysis. A good agreement between conventional and miniature test results exemplifies the potential of the miniature tensile test technique. (author)

  14. Improvements to Technical Specifications surveillance requirements

    International Nuclear Information System (INIS)

    Lobel, R.; Tjader, T.R.

    1992-12-01

    In August 1983 an NRC task group was formed to investigate problems with surveillance testing required by Technical Specifications, and to recommend approaches to effect improvements. NUREG-1024 (''Technical Specifications-Enhancing Safety Impact'') resulted, and it contained recommendations to review the basis for test frequencies; to ensure that the tests promote safety and do not degrade equipment; and to review surveillance tests so that they do not unnecessarily burden personnel. The Technical Specifications Improvement Program (TSIP) was established in December 1984 to provide the framework for rewriting and improving the Technical Specifications. As an element of the TSIP, all Technical Specifications surveillance requirements were comprehensively examined as recommended in NUREG-1024. The results of that effort are presented in this report. The study found that while some testing at power is essential to verify equipment and system operability, safety can be improved, equipment degradation decreased, and unnecessary personnel burden relaxed by reducing the amount of testing at power

  15. Irradiation of UO2 specimens with molten cores in a pressurized water loop. Test X-2-x

    International Nuclear Information System (INIS)

    Bain, A.S.

    1961-08-01

    Two Zircaloy-2 clad specimens containing stoichiometric UO 2 pellets were irradiated in a pressurized water loop for 379 hours at heat ratings sufficient to cause central melting of the UO 2 . There was no appearance of localized overheating or accelerated corrosion of the sheath, but the diametral increases were considerably larger than those observed in loop specimens irradiated at lower heat ratings. The length increases, however, were approximately the same as those measured for specimens at lower ratings. There was a clearly visible demarcation between UO 2 that had been molten and that which had not. The value of ∫ 500 o C Tm kdθ = 74 ± W/cm was essentially the same as that obtained from the short-duration tests in the Hydraulic Rabbit, indicating there is no marked decrease in thermal conductivity of the UO 2 fuel in irradiations up to 379 hours. (author)

  16. The 5th surveillance testing for Kori unit 2 reactor vessel materials

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Ok; Kim, Byoung Chul; Lee, Sam Lai; Choi, Kwon Jae; Gong, Un Sik; Chang, Jong Hwa; Joo, Yong Sun; Ahn, Sang Bok; Hong, Joon Hwa [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2001-03-01

    Surveillance testing for reactor vessel materials is performed in order to evaluate the irradiation embrittlement due to neutrons during operation and set the condition of safe operation of nuclear reactor. The 5th surveillance testing was performed completely by Korea Atomic Energy Research Institute at Taejeon after the capsule was transported from Kori site including its removal from reactor. Fast neutron fluences for capsules were calculated and various testing including mechanical and chemistry analysis were performed in order to evaluate the integrity of Kori unit 2 reactor vessel during the operation until life time. The evaluation results are as follows; Fast neutron fluences for capsules V, R, P, T and N are 2.837E+18, 1.105E+19, 2.110E+19, 3.705E+19 and 4.831E+19n/cm{sup 2}, respectively. The bias factor, the ratio of measurement/calculation, was 0.918 for the 1st through 5th testing and the calculational uncertainty, 11.6% satisfied the requirement of USNRC Reg.Guide DG-1053, 20%. The best estimated neutron fluence for reactor vessel inside surface was 1.898E+19n/cm{sup 2} based on the end of 15th fuel cycle and it was predicted that the fluences of vessel inside surface at 32, 40, 48 and 56EFPY would reach 4.203E+19, 5.232E+19, 6.262E+19 and 7.291E+19n/cm{sup 2} based on the current calculation. The result through this analysis for Kori unit 2 showed that there would be no problem for the pressurized thermal shock(PTS) during the operation until design life. 49 refs., 35 figs., 48 tabs. (Author)

  17. Specimen alignment in an axial tensile test of thin films using direct imaging and its influence on the mechanical properties of BeCu

    International Nuclear Information System (INIS)

    Kang, Dong-Joong; Park, Jun-Hyub; Shin, Myung-Soo; Ha, Jong-Eun; Lee, Hak-Joo

    2010-01-01

    This paper proposes a new system for verification of the alignment of loading fixtures and test specimens during tensile testing of thin film with a micrometer size through direct imaging. The novel and reliable image recognition system to evaluate the misalignment between the load train and the specimen axes during tensile test of thin film was developed using digital image processing technology with CCD. The decision of whether alignment of the tensile specimen is acceptable or not is based on a probabilistic analysis through the edge feature extraction of digital imaging. In order to verify the performance of the proposed system and investigate the effect of the misalignment of the specimen on tensile properties, the tensile tests were performed as displacement control in air and at room temperature for metal thin film, the beryllium copper (BeCu) alloys. In the case of the metal thin films, bending stresses caused by misalignment are insignificant because the films are easily bent during tensile tests to eliminate the bending stresses. And it was observed that little effects and scatters on tensile properties occur by stress gradient caused by twisting at in-plane misalignment, and the effects and scatters on tensile properties are insignificant at out-of-plane misalignment, in the case of the BeCu thin film.

  18. Quantification of Applied Stresses of C-Ring Specimens for Stress Corrosion Cracking Tests

    International Nuclear Information System (INIS)

    Kim, Woo Gon; Kim, Sun Jae; Rhee, Chang Kyu; Kuk, Il Hiun; Choi, Jong Ho

    1997-01-01

    For comparing their resistances for stress-corrosion cracking(SCC) in the K600-MA, K690-MA, and K600-TT tubes, C-ring specimens were fabricated with the various thermal-treatments to control the distributions of the precipitates like Cr-carbides. The bending stresses were analyzed to determine the amounts to make the stress quantitatively to all the C-ring samples, and then the stresses were calculated with the relation to the outer diameter(O.D) deflection(δ) of the C-rings. To measure accurately the bending strains of the C-ring specimens, the strain gauges were used and the compression test was also carried out. In the elastic region, the stresses in both the transverse and the circumferential directions were different with the locations of the strain gauges as attached at α= 30 .deg., 45 .deg., and 90 .deg. to the principal stress direction, but those in the longitudinal direction were independent of their attached locations. Calculated stresses from the strains obtained using the strain gauges were well agreed with the theoretical. In the plastic region over δ=1.0mm, the stresses for the TT tubes showed lower values of about 400MPa than those for the MA tubes. However, the stresses among the TT tubes showed almost the similar values in this region. Therefore, the states of the stresses applied to the C-ring specimens would be different with the material conditions, i.e, the chemical compositions, the thermal treatments such as MA and TT

  19. Agreement for HPV genotyping detection between self-collected specimens on a FTA cartridge and clinician-collected specimens

    Science.gov (United States)

    Guan, YaoYao; Gravitt, Patti E.; Howard, Roslyn; Eby, Yolanda J.; Wang, Shaoming; Li, Belinda; Feng, Changyan; Qiao, You-Lin; Castle, Philip E.

    2016-01-01

    The current method of transporting self-collected cervicovaginal specimen for HPV DNA testing relies on liquid based medium, which is challenging and expensive to transport. A novel, dry storage and transportation device, Whatman indicating FTA™ Elute Cartridge, avoids some of the pitfalls of liquid-based medium. This method has been shown to be comparable to liquid-based collection medium, but relative performance of self-collected (SC) and clinician-collected (CC) samples onto FTA cards has not been reported. The objective of this study is to compare the analytic performance of self- and clinician-collected samples onto FTA cartridges for the detection of carcinogenic HPV using Linear Array. There was a 91% agreement, 69% positive agreement, and kappa of 0.75 between the clinician-collected and self-collected specimens for detection of any carcinogenic HPV genotype. When the HPV results were categorized hierarchically according to cervical cancer risk, there was no difference in the distribution of the HPV results for the clinician- and self-collected specimens (p = 0.7). This study concludes that FTA elute cartridge is a promising method of specimen transport for cervical cancer screening programs considering using self-collected specimen and HPV testing. Larger studies with clinical endpoints are now needed to assess the clinical performance. PMID:23370404

  20. Three surveillance strategies for vancomycin-resistant enterococci in hospitalized patients: detection of colonization efficiency and a cost-effectiveness model.

    Science.gov (United States)

    Lee, Todd A; Hacek, Donna M; Stroupe, Kevin T; Collins, Susan M; Peterson, Lance R

    2005-01-01

    To evaluate the cost-effectiveness and detection sensitivity associated with three active surveillance strategies for the identification of patients harboring vancomycin-resistant enterococci (VRE) to determine which is the most medically and economically useful. Culture for VRE from 200 consecutive stool specimens submitted for Clostridium difficile culture. Following this, risk factors were assessed for patients whose culture yielded VRE, and a cost-effectiveness evaluation was performed using a decision analytic model with a probabilistic analysis. A 688-bed, tertiary-care facility in Chicago, Illinois, with approximately 39,000 annual admissions, 7,000 newborn deliveries, 56,000 emergency department visits, and 115,000 home care and 265,000 outpatient visits. All stool specimens submitted to the clinical microbiology laboratory for C. difficile culture from hospital inpatients. From 200 stool samples submitted for C. difficile testing, we identified 5 patients with VRE in non-high-risk areas not screened as part of our routine patient surveillance. Medical record review revealed that all 5 had been hospitalized within the prior 2 years. Three of 5 had a history of renal impairment. The strategy that would involve screening the greatest number of patients (all those with a history of hospital admission in the prior 2 years) resulted in highest screening cost per patient admitted (dollars 2.48), lower per patient admission costs (dollars 480), and the best survival rates. An expanded VRE surveillance program that encompassed all patients hospitalized within the prior 2 years was a cost-effective screening strategy compared with a more traditional one focused on high-risk units.

  1. Application of advanced irradiation analysis methods to light water reactor pressure vessel test and surveillance programs

    International Nuclear Information System (INIS)

    Odette, R.; Dudey, N.; McElroy, W.; Wullaert, R.; Fabry, A.

    1977-01-01

    Inaccurate characterization and inappropriate application of neutron irradiation exposure variables contribute a substantial amount of uncertainty to embrittlement analysis of light water reactor pressure vessels. Damage analysis involves characterization of the irradiation environment (dosimetry), correlation of test and surveillance metallurgical and dosimetry data, and projection of such data to service conditions. Errors in available test and surveillance dosimetry data are estimated to contribute a factor of approximately 2 to the data scatter. Non-physical (empirical) correlation procedures and the need to extrapolate to the vessel may add further error. Substantial reductions in these uncertainties in future programs can be obtained from a more complete application of available damage analysis tools which have been developed for the fast reactor program. An approach to reducing embrittlement analysis errors is described, and specific examples of potential applications are given. The approach is based on damage analysis techniques validated and calibrated in benchmark environments

  2. Charpy impact test results on five materials and NIST verification specimens using instrumented 2-mm and 8-mm strikers

    International Nuclear Information System (INIS)

    Nanstad, R.K.; Sokolov, M.A.

    1995-01-01

    The Heavy-Section Steel Irradiation Program at Oak Ridge National Laboratory is involved in two cooperative projects, with international participants, both of which involve Charpy V-notch impact tests with instrumented strikers of 2mm and 8mm radii. Two heats of A 533 grade B class I pressure vessel steel and a low upper-shelf (LUS) submerged-arc (SA) weld were tested on the same Charpy machine, while one heat of a Russian Cr-Mo-V forging steel and a high upper-shelf (HUS) SA weld were tested on two different machines. The number of replicate tests at any one temperature ranged from 2 to 46 specimens. Prior to testing with each striker, verification specimens at the low, high, and super high energy levels from the National Institute of Standards and Technology (NIST) were tested. In the two series of verification tests, the tests with the 2mm striker met the requirements at the low and high energy levels but not at the super high energy. For one plate, the 2mm striker showed somewhat higher average absorbed energies than those for the 8-mm striker at all three test temperatures. For the second plate and the LUS weld, however, the 2mm striker showed somewhat lower energies at both test temperatures. For the Russian forging steel and the HUS weld, tests were conducted over a range of temperatures with tests at one laboratory using the 8mm striker and tests at a second laboratory using the 2mm striker. Lateral expansion was measured for all specimens and the results are compared with the absorbed energy results. The overall results showed generally good agreement (within one standard deviation) in energy measurements by the two strikers. Load-time traces from the instrumented strikers were also compared and used to estimate shear fracture percentage. Four different formulas from the European Structural Integrity Society draft standard for instrumented Charpy test are compared and a new formula is proposed for estimation of percent shear from the force-time trace

  3. Specimen's plane misaligned installation solution based on charge fluctuation inside SEM

    Science.gov (United States)

    Lu, Haojian; Liu, Yanting; Yang, Yuanyuan; Wang, Panbing; Shen, Yajing

    2018-04-01

    Precise specimen's installation is a sticking point to ensure the characterization accuracy of the in-situ material property test. Although it is common knowledge that specimen's plane misaligned installation (PMI) would cause extra force loading during mechanical testing, there are few effective solutions available to deal with it at the current stage, especially during the in-situ scanning electron microscopy (SEM) test. Taking into consideration the charge fluctuation phenomenon under SEM, this paper proposes a highlight area variation (HAV) method for specimen deformation judgment, i.e., the specimen deformation is defined when the highlight area changes greater than 20% of the initial value of the specimen surface. Three types of specimens with different resistivities, i.e., human hair (electrical resistivity ˜3 × 1012 Ω cm), optical fiber (electrical resistivity ˜1017 Ω cm), and magnetic wire (electrical resistivity ˜2 × 10-5 Ω cm), are chosen to verify the effectiveness of the HAV method. Furthermore, combined with the developed robot-aided alignment system, the specimen's PMI problem can also be solved. In the demonstration, the human hair specimen is installed across two specimen stages and its in-situ twisting (in 360°) test is implemented. The results clearly indicate that the HAV method and the robot-aided alignment system are practical and reliable, and the specimen can be aligned on the same plane and installed precisely with accuracy up to 3 μm. This method will benefit the in-situ SEM material mechanical property test and has a significant impact in fundamental material research.

  4. Shear compression testing of glass-fibre steel specimens after 4K reactor irradiation: Present status and facility upgrade

    International Nuclear Information System (INIS)

    Gerstenberg, H.; Kraehling, E.; Katheder, H.

    1997-01-01

    The shear strengths of various fibre reinforced resins being promising candidate insulators for superconducting coils to be used tinder a strong radiation load, e.g. in future fusion reactors were investigated prior and subsequent to reactor in-core irradiation at liquid helium temperature. A large number of sandwich-like (steel-bonded insulation-steel) specimens representing a widespread variety of materials and preparation techniques was exposed to irradiation doses of up to 5 x 10 7 Gy in form of fast neutrons and γ-radiation. In a systematic study several experimental parameters including irradiation dose, postirradiation storage temperature and measuring temperature were varied before the determination of the ultimate shear strength. The results obtained from the different tested materials are compared. In addition an upgrade of the in-situ test rig installed at the Munich research reactor is presented, which allows combined shear/compression loading of low temperature irradiated specimens and provides a doubling of the testing rate

  5. Determination of necking time in tensile test specimens, under high-temperature creep conditions, subjected to distribution of stresses over the cross-section

    Science.gov (United States)

    Lokoshchenko, A.; Teraud, W.

    2018-04-01

    The work describes an experimental research of creep of cylindrical tensile test specimens made of aluminum alloy D16T at a constant temperature of 400°C. The issue to be examined was the necking at different values of initial tensile stresses. The use of a developed noncontacting measuring system allowed us to see variations in the specimen shape and to estimate the true stress in various times. Based on the obtained experimental data, several criteria were proposed for describing the point of time at which the necking occurs (necking point). Calculations were carried out at various values of the parameters in these criteria. The relative interval of deformation time in which the test specimen is uniformly stretched was also determined.

  6. Redesigning axial-axial (biaxial) cruciform specimens for very high cycle fatigue ultrasonic testing machines.

    Science.gov (United States)

    Montalvão, Diogo; Wren, Andrew

    2017-11-01

    The necessity to increase performances in terms of lifetime and security in mechanical components or structures is the motivation for intense research in fatigue. Applications range from aeronautics to medical devices. With the development of new materials, there is no longer a fatigue limit in the classical sense, where it was accepted that the fatigue limit is the stress level such that there is no fracture up to 1E7 cycles. The recent development of ultrasonic testing machines where frequencies can go as high as 20 kHz or over enabled tests to be extended to ranges larger than 1E9 in just a few days. This area of studies is now known as Very High Cycle Fatigue (VHCF). On the other hand, most of the existing test equipment in the market for both classical and VHCF are uniaxial test machines. However, critical components used in Engineering applications are usually subjected to complex multi-axial loading conditions. In this paper, it is presented the methodology to redesigning existing cruciform test specimens that can be used to create an in-plane biaxial state of stress when used in 'uniaxial' VHCF ultrasonic testing machines (in this case, the term 'uniaxial' is used not because of the state of stress created at the centre of the specimen, but because of the direction at which the load is applied). The methodology is explained in such a way that it can be expanded to other existing designs, namely cruciform designs, that are not yet used in VHCF. Also, although the approach is presented in simple and logical terms, it may not be that obvious for those who have a more focused approach on fatigue rather than on modal analysis. It is expected that by contributing to bridging the gap between the sciences of modal analysis and fatigue, this research will help and encourage others exploiting new capabilities in VHCF.

  7. Charpy impact test of oxidized and hydrogenated zircaloy using a thin strip specimen

    International Nuclear Information System (INIS)

    Otsuka, Teppei; Hashizume, Kenichi; Sugisaki, Masayasu

    2004-01-01

    The impact properties of an oxidized and a hydrogenated Zircaloy have been studied with an instrumented Charpy machine by using a strip Charpy V-notch specimen (1 mm thick by 4mm wide). Fracture processes such as crack initiation and propagation were examined using load-displacement curves obtained in this study. In the case of the hydrogenated specimen containing preferentially oriented hydrides, an appreciable decrease in the absorbed energy was observed in the crack propagation rather than in the crack initiation. From results of fractographs of the specimen, it was suggested that the reduction of the crack propagation energy of hydrogenated specimen could be attributed to the change of the stress state in the Zircaloy matrix, which was caused by the fracture of hydride in the inner part of specimen. In the case of the specimen oxidized at 973k for 60 min, on which an oxide layer (4 μm in thickness) and oxygen incursion layer (4μm) were formed, the surface layers affected the crack initiation process. The growing oxygen incursion layer, in particular, resulted in the constraint of plastic deformation of the Zircaloy matrix not only in the crack initiation but also in the crack propagation as its thickness increased. (author)

  8. Fracture mechanics characterisation of medium-size adhesive joint specimens

    DEFF Research Database (Denmark)

    Sørensen, Bent F.; Jacobsen, T.K.

    2004-01-01

    Medium-size specimens (glass-fibre beams bonded together by an adhesive layer were tested in four point bending to determine their load carrying capacity. Specimens having different thickness were tested. Except for onespecimen, the cracking occurred as cracking...... along the adhesive layer; initially cracking occurred along the adhesive/laminate interface, but after some crack extension the cracking took place inside the laminate (for one specimen the later part of thecracking occurred unstably along the adhesive/ laminate interface). Crack bridging by fibres...

  9. 9 CFR 93.204 - Import permits for poultry and for poultry test specimens for diagnostic purposes; and...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Import permits for poultry and for poultry test specimens for diagnostic purposes; and reservation fees for space at quarantine facilities... SERVICE, DEPARTMENT OF AGRICULTURE EXPORTATION AND IMPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL...

  10. Surveillance of antibiotic resistance

    Science.gov (United States)

    Johnson, Alan P.

    2015-01-01

    Surveillance involves the collection and analysis of data for the detection and monitoring of threats to public health. Surveillance should also inform as to the epidemiology of the threat and its burden in the population. A further key component of surveillance is the timely feedback of data to stakeholders with a view to generating action aimed at reducing or preventing the public health threat being monitored. Surveillance of antibiotic resistance involves the collection of antibiotic susceptibility test results undertaken by microbiology laboratories on bacteria isolated from clinical samples sent for investigation. Correlation of these data with demographic and clinical data for the patient populations from whom the pathogens were isolated gives insight into the underlying epidemiology and facilitates the formulation of rational interventions aimed at reducing the burden of resistance. This article describes a range of surveillance activities that have been undertaken in the UK over a number of years, together with current interventions being implemented. These activities are not only of national importance but form part of the international response to the global threat posed by antibiotic resistance. PMID:25918439

  11. Agreement for HPV genotyping detection between self-collected specimens on a FTA cartridge and clinician-collected specimens.

    Science.gov (United States)

    Guan, Yaoyao; Gravitt, Patti E; Howard, Roslyn; Eby, Yolanda J; Wang, Shaoming; Li, Belinda; Feng, Changyan; Qiao, You-Lin; Castle, Philip E

    2013-04-01

    The current method of transporting self-collected cervicovaginal specimen for HPV DNA testing relies on liquid based medium, which is challenging and expensive to transport. A novel, dry storage and transportation device, Whatman indicating FTA™ Elute Cartridge, avoids some of the pitfalls of liquid-based medium. This method has been shown to be comparable to liquid-based collection medium, but relative performance of self-collected (SC) and clinician-collected (CC) samples onto FTA cards has not been reported. The objective of this study is to compare the analytic performance of self- and clinician-collected samples onto FTA cartridges for the detection of carcinogenic HPV using Linear Array. There was a 91% agreement, 69% positive agreement, and kappa of 0.75 between the clinician-collected and self-collected specimens for detection of any carcinogenic HPV genotype. When the HPV results were categorized hierarchically according to cervical cancer risk, there was no difference in the distribution of the HPV results for the clinician- and self-collected specimens (p=0.7). This study concludes that FTA elute cartridge is a promising method of specimen transport for cervical cancer screening programs considering using self-collected specimen and HPV testing. Larger studies with clinical endpoints are now needed to assess the clinical performance. Copyright © 2012 Elsevier B.V. All rights reserved.

  12. Application Anti Microbial Activity Test and Direct Inoculation of Urinary Specimen Test to Increase the Quality of Results and Decrease the Production Cost in Clinical Microbiology Laboratory, Sanglah General Hospital Hospital, Bali-Indonesia

    Directory of Open Access Journals (Sweden)

    Nyoman Sri-Budayanti

    2012-05-01

    Full Text Available Objective: Urinary tract infection (UTI is the most common bacterial infection in general practice and in hospitals. Fast and accurate urine culture and sensitivity test are needed for adequate therapy. Anti Microbial Activity test (AMA test that is used to detect the presence of antibiotics in urine specimens is not commonly used in clinical microbiology laboratories. Some laboratories are still using indirect inoculation technique using enriched media before inoculating onto the agar media. The aim of this research is to compare results of urinary examination of direct inoculation technique with AMA test with indirect inoculation technique without AMA test.Methods: A number of 210 urine specimens were collected in Clinical Microbiology Laboratory at Sanglah General Hospital within a time period between 16 June until 16 July 2009.Results: Antibiotics were detected in 40% of the urinary specimens; whereas 48.1% showed no evidence of UTI, that is negative AMA test and sterile urinary culture or colony growth < 105 CFU/ml. Only 11.9% of the specimens indicates urinary tract infections. The examination can be completed within 2-3 days which is shorter than indirect inoculation test which require 5-7 days. Direct inoculation technique can reduce the cost of production three-fold the costs require for an indirect inoculation test.Conclusions: Application of AMA test and direct inoculation technique can give results more rapidly, reliable and useful for clinicians. This also decrease the laboratory’s cost of production.

  13. Establishment, test and evaluation of a prototype volcano surveillance system

    Science.gov (United States)

    Ward, P. L.; Eaton, J. P.; Endo, E.; Harlow, D.; Marquez, D.; Allen, R.

    1973-01-01

    A volcano-surveillance system utilizing 23 multilevel earthquake counters and 6 biaxial borehole tiltmeters is being installed and tested on 15 volcanoes in 4 States and 4 foreign countries. The purpose of this system is to give early warning when apparently dormant volcanoes are becoming active. The data are relayed through the ERTS-Data Collection System to Menlo Park for analysis. Installation was completed in 1972 on the volcanoes St. Augustine and Iliamna in Alaska, Kilauea in Hawaii, Baker, Rainier and St. Helens in Washington, Lassen in California, and at a site near Reykjavik, Iceland. Installation continues and should be completed in April 1973 on the volcanoes Santiaguito, Fuego, Agua and Pacaya in Guatemala, Izalco in El Salvador and San Cristobal, Telica and Cerro Negro in Nicaragua.

  14. Molecular Auditing: An Evaluation of Unsuspected Tissue Specimen Misidentification.

    Science.gov (United States)

    Demetrick, Douglas J

    2018-06-18

    Context Specimen misidentification is the most significant error in laboratory medicine, potentially accounting for hundreds of millions of dollars in extra health care expenses and significant morbidity in patient populations in the United States alone. New technology allows the unequivocal documentation of specimen misidentification or contamination; however, the value of this technology currently depends on suspicion of the specimen integrity by a pathologist or other health care worker. Objective To test the hypothesis that there is a detectable incidence of unsuspected tissue specimen misidentification among cases submitted for routine surgical pathology examination. Design To test this hypothesis, we selected specimen pairs that were obtained at different times and/or different hospitals from the same patient, and compared their genotypes using standardized microsatellite markers used commonly for forensic human DNA comparison in order to identify unsuspected mismatches between the specimen pairs as a trial of "molecular auditing." We preferentially selected gastrointestinal, prostate, and skin biopsies because we estimated that these types of specimens had the greatest potential for misidentification. Results Of 972 specimen pairs, 1 showed an unexpected discordant genotype profile, indicating that 1 of the 2 specimens was misidentified. To date, we are unable to identify the etiology of the discordance. Conclusions These results demonstrate that, indeed, there is a low level of unsuspected tissue specimen misidentification, even in an environment with careful adherence to stringent quality assurance practices. This study demonstrates that molecular auditing of random, routine biopsy specimens can identify occult misidentified specimens, and may function as a useful quality indicator.

  15. Cryptosporidium surveillance and risk factors in the United States.

    Science.gov (United States)

    Yoder, Jonathan S; Beach, Michael J

    2010-01-01

    Surveillance for Cryptosporidium in the United States indicates that the reported incidence of infection has increased dramatically since 2004. The reasons for this increase are unclear but might be caused by an actual increase in incidence, improved surveillance, improved awareness about cryptosporidiosis, and/or increases in testing practices resulting from the licensing of the first-ever treatment for cryptosporidiosis. While regional differences remain, the incidence of cryptosporidiosis appears to be increasing across the United States. Onset of illness is most common during the summer, particularly among younger children. Cryptosporidiosis case reporting also influences outbreak detection and reporting; the recent rise in cases coincides with an increase in the number of reported cryptosporidiosis outbreaks, particularly in treated recreational water venues. Risk factors include ingesting contaminated recreational or drinking water, exposure to infected animals, having close contacts with cryptosporidiosis, travel to disease-endemic areas, and ingestion of contaminated food. Advances in molecular characterization of clinical specimens have improved our understanding of the changing epidemiology and risk factors. Prevention and control of cryptosporidiosis requires continued efforts to interrupt the transmission of Cryptosporidium through water, food, and contact with infected persons or animals. Of particular importance is continued improvement and monitoring of drinking water treatment and advances in the design, operation, and management of recreational water venues coupled with behavioral changes among the swimming public. Published by Elsevier Inc.

  16. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants

    International Nuclear Information System (INIS)

    Romero C, J.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.; Garcia R, R.

    2007-01-01

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  17. Strain Measurement System Developed for Biaxially Loaded Cruciform Specimens

    Science.gov (United States)

    Krause, David L.

    2000-01-01

    A new extensometer system developed at the NASA Glenn Research Center at Lewis Field measures test area strains along two orthogonal axes in flat cruciform specimens. This system incorporates standard axial contact extensometers to provide a cost-effective high-precision instrument. The device was validated for use by extensive testing of a stainless steel specimen, with specimen temperatures ranging from room temperature to 1100 F. In-plane loading conditions included several static biaxial load ratios, plus cyclic loadings of various waveform shapes, frequencies, magnitudes, and durations. The extensometer system measurements were compared with strain gauge data at room temperature and with calculated strain values for elevated-temperature measurements. All testing was performed in house in Glenn's Benchmark Test Facility in-plane biaxial load frame.

  18. Design of four-point SENB specimens with stable crack growth

    DEFF Research Database (Denmark)

    Jørgensen, Jeppe Bjørn; Kildegaard, Casper; Sørensen, Bent F.

    2018-01-01

    A four-point single-edge-notch-beam (SENB) test specimen loaded in displacement control (fixed grip) is proposed for studying crack deflection at bi-material interfaces. In order to ensure stable crack growth, a novel analytical model of the four-point SENB specimen in fixed grip is derived...... and compared with numerical models. Model results show that the specimen should be short and thick, and the start-crack length should be deep for the crack to propagate stable towards the bi-material interface. Observations from experimental tests of four-point SENB specimens with different start-crack lengths...

  19. Development of a supplemental surveillance program for reactor pressure vessel thermal annealing

    International Nuclear Information System (INIS)

    Server, W.L.; Rosinski, S.T.

    1997-01-01

    The technical decision to thermally anneal a nuclear reactor pressure vessel (RPV) depends upon the level of embrittlement in the RPV steels, the amount of recovery of fracture toughness properties expected from the anneal, and the rate of re-embrittlement after the vessel is placed back into service. The recovery of Charpy impact toughness properties after annealing can be estimated initially by using a recovery model developed using experimental measurements of recovery (such as that developed by Eason et al. for U.S. vessel materials). However, actual validation measurements on plant-specific archived vessel materials (hopefully in the existing surveillance program) are needed; otherwise, irradiated surrogate materials, essentially the same as the RPV steels or bounding in expected behavior, must be utilized. The efficient use of any of these materials requires a supplemental surveillance program focused at both recovery and reirradiation embrittlement. Reconstituted Charpy specimens and new surveillance capsules will most likely be needed as part of this supplemental surveillance program. A new version of ASTM E 509 has recently been approved which provides guidance on thermal annealing in general and specifically for the development of an annealing supplemental surveillance program. The post-anneal re-embrittlement properties are crucial for continued plant operation, and the use of a re-embrittlement model, such as the lateral shift approach, may be overly conservative. This paper illustrates the new ASTM E 509 Standard Guide methodology for an annealing supplemental surveillance program. As an example, the proposed program for the Palisades RPV beltline steels is presented which covers the time from annealing to the end of operating license and beyond, if license renewal is pursued. The Palisades nuclear power plant RPV was planned to be annealed in 1998, but that plant is currently being re-evaluated. The proposed anneal was planned to be conducted at a

  20. Implementing hospital-based surveillance for severe acute respiratory infections caused by influenza and other respiratory pathogens in New Zealand

    Directory of Open Access Journals (Sweden)

    Q Sue Huang

    2014-05-01

    Full Text Available Background: Recent experience with pandemic influenza A(H1N1pdm09 highlighted the importance of global surveillance for severe respiratory disease to support pandemic preparedness and seasonal influenza control. Improved surveillance in the southern hemisphere is needed to provide critical data on influenza epidemiology, disease burden, circulating strains and effectiveness of influenza prevention and control measures. Hospital-based surveillance for severe acute respiratory infection (SARI cases was established in New Zealand on 30 April 2012. The aims were to measure incidence, prevalence, risk factors, clinical spectrum and outcomes for SARI and associated influenza and other respiratory pathogen cases as well as to understand influenza contribution to patients not meeting SARI case definition. Methods/Design: All inpatients with suspected respiratory infections who were admitted overnight to the study hospitals were screened daily. If a patient met the World Health Organization’s SARI case definition, a respiratory specimen was tested for influenza and other respiratory pathogens. A case report form captured demographics, history of presenting illness, co-morbidities, disease course and outcome and risk factors. These data were supplemented from electronic clinical records and other linked data sources. Discussion: Hospital-based SARI surveillance has been implemented and is fully functioning in New Zealand. Active, prospective, continuous, hospital-based SARI surveillance is useful in supporting pandemic preparedness for emerging influenza A(H7N9 virus infections and seasonal influenza prevention and control.

  1. COMPARISON BETWEEN WOOD DRYING DEFECT SCORES: SPECIMEN TESTING X ANALYSIS OF KILN-DRIED BOARDS

    OpenAIRE

    Djeison Cesar Batista; Márcio Pereira da Rocha; Ricardo Jorge Klitzke

    2015-01-01

    It is important to develop drying technologies for Eucalyptus grandis lumber, which is one of the most planted species of this genus in Brazil and plays an important role as raw material for the wood industry. The general aim of this work was to assess the conventional kiln drying of juvenile wood of three clones of Eucalyptus grandis. The specific aims were to compare the behavior between: i) drying defects indicated by tests with wood specimens and conventional kiln-dried boards; and ii) ph...

  2. Appropriateness of endoscopic surveillance recommendations in organised colorectal cancer screening programmes based on the faecal immunochemical test.

    Science.gov (United States)

    Zorzi, Manuel; Senore, Carlo; Turrin, Anna; Mantellini, Paola; Visioli, Carmen Beatriz; Naldoni, Carlo; Sassoli De' Bianchi, Priscilla; Fedato, Chiara; Anghinoni, Emanuela; Zappa, Marco; Hassan, Cesare

    2016-11-01

    To assess the appropriateness of recommendations for endoscopic surveillance in organised colorectal cancer (CRC) screening programmes based on the faecal immunochemical test (FIT). 74 Italian CRC screening programmes provided aggregated data on the recommendations given after FIT-positive colonoscopies in 2011 and 2013. Index colonoscopies were divided into negative/no adenoma and low- risk, intermediate-risk and high-risk adenomas. Postcolonoscopy recommendations included a return to screening (FIT after 2 years or 5 years), an endoscopic surveillance after 6 months or after 1 year, 3 years or 5 years, surgery or other. We assessed the deviation from the postcolonoscopy recommendations of the European Guidelines in 2011 and 2013 and the correlation between overuse of endoscopic surveillance in 2011 and the process indicators associated with the endoscopic workload in 2013. 49 704 postcolonoscopy recommendations were analysed. High-risk, intermediate-risk and low-risk adenomas, and no adenomas were reported in 5.9%, 19.3%, 15.3% and 51.5% of the cases, respectively. Endoscopic surveillance was inappropriately recommended in 67.4% and 7%, respectively, of cases with low-risk and no adenoma. Overall, 37% of all endoscopic surveillance recommendations were inappropriate (6696/17 860). Overuse of endoscopic surveillance was positively correlated with the extension of invitations (correlation coefficient (cc) 0.29; p value 0.03) and with compliance with post-FIT+ colonoscopy (cc 0.25; p value 0.05), while it was negatively correlated with total colonoscopy waiting times longer than 60 days (cc -0.26; p value 0.05). In organised screening programmes, a high rate of inappropriate recommendations for patients with low risk or no adenomas occurs, affecting the demand for endoscopic surveillance by a third. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. The use of a mobile laboratory unit in support of patient management and epidemiological surveillance during the 2005 Marburg Outbreak in Angola.

    Directory of Open Access Journals (Sweden)

    Allen Grolla

    2011-05-01

    Full Text Available BACKGROUND: Marburg virus (MARV, a zoonotic pathogen causing severe hemorrhagic fever in man, has emerged in Angola resulting in the largest outbreak of Marburg hemorrhagic fever (MHF with the highest case fatality rate to date. METHODOLOGY/PRINCIPAL FINDINGS: A mobile laboratory unit (MLU was deployed as part of the World Health Organization outbreak response. Utilizing quantitative real-time PCR assays, this laboratory provided specific MARV diagnostics in Uige, the epicentre of the outbreak. The MLU operated over a period of 88 days and tested 620 specimens from 388 individuals. Specimens included mainly oral swabs and EDTA blood. Following establishing on site, the MLU operation allowed a diagnostic response in <4 hours from sample receiving. Most cases were found among females in the child-bearing age and in children less than five years of age. The outbreak had a high number of paediatric cases and breastfeeding may have been a factor in MARV transmission as indicated by the epidemiology and MARV positive breast milk specimens. Oral swabs were a useful alternative specimen source to whole blood/serum allowing testing of patients in circumstances of resistance to invasive procedures but limited diagnostic testing to molecular approaches. There was a high concordance in test results between the MLU and the reference laboratory in Luanda operated by the US Centers for Disease Control and Prevention. CONCLUSIONS/SIGNIFICANCE: The MLU was an important outbreak response asset providing support in patient management and epidemiological surveillance. Field laboratory capacity should be expanded and made an essential part of any future outbreak investigation.

  4. Polio eradication in India: progress, but environmental surveillance and vigilance still needed.

    Science.gov (United States)

    Chatterjee, Animesh; Vidyant, Sanjukta; Dhole, Tapan N

    2013-02-18

    Poliomyelitis has appeared in epidemic form, become endemic on a global scale, and has been reduced to near elimination, all within the span of documented medical history. Nevertheless, effective vaccinations, global surveillance network, development of accurate viral diagnosis prompted the historical challenge, global polio eradication initiative (GPEI). Environmental surveillance of poliovirus means monitoring of wild polio virus (WPV) and vaccine derived polio virus (cVDPV) circulation in human populations by examining environmental specimens supposedly contaminated by human feces. The rationale for surveillance is based on the fact that PV-infected individuals, whether presenting with disease symptoms or not, shed large amounts of PV in the feces for several weeks. As the morbidity: infection ratio of PV infection is very low, and therefore this fact contributes to the sensitivity of poliovirus surveillance, which under optimal conditions can be better than that of the standard acute flaccid paralysis (AFP) surveillance. The World Health Organization (WHO) has included environmental surveillance of poliovirus in the new Strategic Plan of the Global Polio Eradication Initiative for years 2010-2012 to be increasingly used in PV surveillance, supplementing AFP surveillance and the strategic advisory group of experts on immunization (SAGE) recommended a switch from tOPV-bOPV to remove the threat of cVDPV2 and to accelerate the elimination of WPV type 1 and 3 as bOPV is a more immunogenic vaccine and to introduce one dose of IPV in their vaccination schedule prior to OPV cessation. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Comparison of fracture toughness values from large-scale pipe system tests and C(T) specimens

    International Nuclear Information System (INIS)

    Olson, R.; Scott, P.; Marschall, C.; Wilkowski, G.

    1993-01-01

    Within the International Piping Integrity Research Group (IPIRG) program, pipe system experiments involving dynamic loading with intentionally circumferentially cracked pipe were conducted. The pipe system was fabricated from 406-mm (16-inch) diameter Schedule 100 pipe and the experiments were conducted at 15.5 MPa (2,250 psi) and 288 C (550 F). The loads consisted of pressure, dead-weight, thermal expansion, inertia, and dynamic anchor motion. Significant instrumentation was used to allow the material fracture resistance to be calculated from these large-scale experiments. A comparison of the toughness values from the stainless steel base metal pipe experiment of standard quasi-static and dynamic C(T) specimen tests showed the pipe toughness value was significantly lower than that obtained from C(T) specimens. It is hypothesized that the cyclic loading from inertial stresses in this pipe system experiment caused local degradation of the material toughness. Such effects are not considered in current LBB or pipe flaw evaluation criteria. 4 refs., 14 figs., 1 tab

  6. Control of the ORR-PSF pressure-vessel surveillance irradiation experiment temperature

    International Nuclear Information System (INIS)

    Miller, L.F.

    1982-01-01

    Control of the Oak Ridge Research Reactor Pool Side Facility (ORR-PSF) pressure vessel surveillance irradiation experiment temperature is implemented by digital computer control of electrical heaters under fixed cooling conditions. Cooling is accomplished with continuous flows of water in pipes between specimen sets and of helium-neon gas in the specimen set housings. Control laws are obtained from solutions of the discrete-time Riccati equation and are implemented with direct digital control of solid state relays in the electrical heater circuit. Power dissipated by the heaters is determined by variac settings and the percent of time that the solid state relays allow power to be supplied to the heaters. Control demands are updated every forty seconds

  7. Biaxial Creep Specimen Fabrication

    Energy Technology Data Exchange (ETDEWEB)

    JL Bump; RF Luther

    2006-02-09

    This report documents the results of the weld development and abbreviated weld qualification efforts performed by Pacific Northwest National Laboratory (PNNL) for refractory metal and superalloy biaxial creep specimens. Biaxial creep specimens were to be assembled, electron beam welded, laser-seal welded, and pressurized at PNNL for both in-pile (JOYO reactor, O-arai, Japan) and out-of-pile creep testing. The objective of this test campaign was to evaluate the creep behavior of primary cladding and structural alloys under consideration for the Prometheus space reactor. PNNL successfully developed electron beam weld parameters for six of these materials prior to the termination of the Naval Reactors program effort to deliver a space reactor for Project Prometheus. These materials were FS-85, ASTAR-811C, T-111, Alloy 617, Haynes 230, and Nirnonic PE16. Early termination of the NR space program precluded the development of laser welding parameters for post-pressurization seal weldments.

  8. Biaxial Creep Specimen Fabrication

    International Nuclear Information System (INIS)

    JL Bump; RF Luther

    2006-01-01

    This report documents the results of the weld development and abbreviated weld qualification efforts performed by Pacific Northwest National Laboratory (PNNL) for refractory metal and superalloy biaxial creep specimens. Biaxial creep specimens were to be assembled, electron beam welded, laser-seal welded, and pressurized at PNNL for both in-pile (JOYO reactor, O-arai, Japan) and out-of-pile creep testing. The objective of this test campaign was to evaluate the creep behavior of primary cladding and structural alloys under consideration for the Prometheus space reactor. PNNL successfully developed electron beam weld parameters for six of these materials prior to the termination of the Naval Reactors program effort to deliver a space reactor for Project Prometheus. These materials were FS-85, ASTAR-811C, T-111, Alloy 617, Haynes 230, and Nirnonic PE16. Early termination of the NR space program precluded the development of laser welding parameters for post-pressurization seal weldments

  9. Advantages and disadvantages of technologies for HER2 testing in breast cancer specimens.

    Science.gov (United States)

    Furrer, Daniela; Sanschagrin, François; Jacob, Simon; Diorio, Caroline

    2015-11-01

    Human epidermal growth factor receptor 2 (HER2) plays a central role as a prognostic and predictive marker in breast cancer specimens. Reliable HER2 evaluation is central to determine the eligibility of patients with breast cancer to targeted anti-HER2 therapies such as trastuzumab and lapatinib. Presently, several methods exist for the determination of HER2 status at different levels (protein, RNA, and DNA level). In this review, we discuss the main advantages and disadvantages of the techniques developed so far for the evaluation of HER2 status in breast cancer specimens. Each technique has its own advantages and disadvantages. It is therefore not surprising that no consensus has been reached so far on which technique is the best for the determination of HER2 status. Currently, emphasis must be put on standardization of procedures, internal and external quality control assessment, and competency evaluation of already existing methods to ensure accurate, reliable, and clinically meaningful test results. Development of new robust and accurate diagnostic assays should also be encouraged. In addition, large clinical trials are warranted to identify the technique that most reliably predicts a positive response to anti-HER2 drugs. Copyright© by the American Society for Clinical Pathology.

  10. Molecular surveillance of norovirus, 2005-16 : an epidemiological analysis of data collected from the NoroNet network

    NARCIS (Netherlands)

    van Beek, Janko; de Graaf, Miranda; Al-Hello, Haider; Allen, David J; Ambert-Balay, Katia; Botteldoorn, Nadine; Brytting, Mia; Buesa, Javier; Cabrerizo, Maria; Chan, Martin; Cloak, Fiona; Di Bartolo, Ilaria; Guix, Susana; Hewitt, Joanne; Iritani, Nobuhiro; Jin, Miao; Johne, Reimar; Lederer, Ingeborg; Mans, Janet; Martella, Vito; Maunula, Leena; McAllister, Georgina; Niendorf, Sandra; Niesters, Hubert G; Podkolzin, Alexander T; Poljsak-Prijatelj, Mateja; Rasmussen, Lasse Dam; Reuter, Gábor; Tuite, Gráinne; Kroneman, Annelies; Vennema, Harry; Koopmans, Marion P G

    BACKGROUND: The development of a vaccine for norovirus requires a detailed understanding of global genetic diversity of noroviruses. We analysed their epidemiology and diversity using surveillance data from the NoroNet network. METHODS: We included genetic sequences of norovirus specimens obtained

  11. Elastic-plastic analysis of the SS-3 tensile specimen

    International Nuclear Information System (INIS)

    Majumdar, S.

    1998-01-01

    Tensile tests of most irradiated specimens of vanadium alloys are conducted using the miniature SS-3 specimen which is not ASTM approved. Detailed elastic-plastic finite element analysis of the specimen was conducted to show that, as long as the ultimate to yield strength ratio is less than or equal to 1.25 (which is satisfied by many irradiated materials), the stress-plastic strain curve obtained by using such a specimen is representative of the true material behavior

  12. Thermo-mechanical Fatigue Failure of Thermal Barrier Coated Superalloy Specimen

    Science.gov (United States)

    Subramanian, Rajivgandhi; Mori, Yuzuru; Yamagishi, Satoshi; Okazaki, Masakazu

    2015-09-01

    Failure behavior of thermal barrier coated (TBC) Ni-based superalloy specimens were studied from the aspect of the effect of bond coat material behavior on low cycle fatigue (LCF) and thermo-mechanical fatigue (TMF) at various temperatures and under various loading conditions. Initially, monotonic tensile tests were carried out on a MCrAlY alloy bond coat material in the temperature range of 298 K to 1273 K (25 °C to 1000 °C). Special attention was paid to understand the ductile to brittle transition temperature (DBTT). Next, LCF and TMF tests were carried out on the thermal barrier coated Ni-based alloy IN738 specimen. After these tests, the specimens were sectioned to understand their failure mechanisms on the basis of DBTT of the bond coat material. Experimental results demonstrated that the LCF and TMF lives of the TBC specimen were closely related to the DBTT of the bond coat material, and also the TMF lives were different from those of LCF tests. It has also been observed that the crack density in the bond coat in the TBC specimen was significantly dependent on the test conditions. More importantly, not only the number of cracks but also the crack penetration probability into substrate were shown to be sensitive to the DBTT.

  13. Evaluation of constraint methodologies applied to a shallow-flaw cruciform bend specimen tested under biaxial loading conditions

    International Nuclear Information System (INIS)

    Bass, B.R.; McAfee, W.J.; Williams, P.T.; Pennell, W.E.

    1998-01-01

    A technology to determine shallow-flaw fracture toughness of reactor pressure vessel (RPV) steels is being developed for application to the safety assessment of RPVs containing postulated shallow surface flaws. Matrices of cruciform beam tests were developed to investigate and quantify the effects of temperature, biaxial loading, and specimen size on fracture initiation toughness of two-dimensional (constant depth), shallow surface flaws. The cruciform beam specimens were developed at Oak Ridge National Laboratory (ORNL) to introduce a prototypic, far-field. out-of-plane biaxial stress component in the test section that approximates the nonlinear stresses resulting from pressurized-thermal-shock or pressure-temperature loading of an RPV. Tests were conducted under biaxial load ratios ranging from uniaxial to equibiaxial. These tests demonstrated that biaxial loading can have a pronounced effect on shallow-flaw fracture toughness in the lower transition temperature region for RPV materials. The cruciform fracture toughness data were used to evaluate fracture methodologies for predicting the observed effects of biaxial loading on shallow-flaw fracture toughness. Initial emphasis was placed on assessment of stress-based methodologies. namely, the J-Q formulation, the Dodds-Anderson toughness scaling model, and the Weibull approach. Applications of these methodologies based on the hydrostatic stress fracture criterion indicated an effect of loading-biaxiality on fracture toughness, the conventional maximum principal stress criterion indicated no effect

  14. Feasibility Study of Laser Cutting for Fabrication of Tensile Specimen

    International Nuclear Information System (INIS)

    Jin, Y. G.; Baik, S. J.; Kim, G. S.; Heo, G. S.; Yoo, B. O.; Ahn, S. B.; Chun, Y. B.

    2015-01-01

    The specimen fabrication technique was established to machine the specimen from the irradiated materials. The wire cut EDM(electric discharge machine) was modified to fabricate the mechanical testing specimens from irradiated components and fuel claddings. The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated components and claddings interrupted the applying the electric current during the processing. However, zirconium oxide is protective against further corrosion as well as beneficial to mechanical strength for the tensile deformation of the cladding. Thus, it is important to fabricate the irradiated specimens without removal of oxide layer on the surface of the irradiated structural components and claddings. In the present study, laser cutting system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the feasibility of the laser cutting system was studied for the fabrication of various types of irradiated specimens in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser beam machining system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the dimensions were compared for the feasibility of the laser cutting system. The effect of surface oxide layer was also investigated for machining process of the zircaloy-4 fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer

  15. Feasibility Study of Laser Cutting for Fabrication of Tensile Specimen

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Y. G.; Baik, S. J.; Kim, G. S.; Heo, G. S.; Yoo, B. O.; Ahn, S. B.; Chun, Y. B. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    The specimen fabrication technique was established to machine the specimen from the irradiated materials. The wire cut EDM(electric discharge machine) was modified to fabricate the mechanical testing specimens from irradiated components and fuel claddings. The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated components and claddings interrupted the applying the electric current during the processing. However, zirconium oxide is protective against further corrosion as well as beneficial to mechanical strength for the tensile deformation of the cladding. Thus, it is important to fabricate the irradiated specimens without removal of oxide layer on the surface of the irradiated structural components and claddings. In the present study, laser cutting system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the feasibility of the laser cutting system was studied for the fabrication of various types of irradiated specimens in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser beam machining system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the dimensions were compared for the feasibility of the laser cutting system. The effect of surface oxide layer was also investigated for machining process of the zircaloy-4 fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer.

  16. Incidence and Trends of Infections with Pathogens Transmitted Commonly Through Food and the Effect of Increasing Use of Culture-Independent Diagnostic Tests on Surveillance - Foodborne Diseases Active Surveillance Network, 10 U.S. Sites, 2013-2016.

    Science.gov (United States)

    Marder, Ellyn P; Cieslak, Paul R; Cronquist, Alicia B; Dunn, John; Lathrop, Sarah; Rabatsky-Ehr, Therese; Ryan, Patricia; Smith, Kirk; Tobin-D'Angelo, Melissa; Vugia, Duc J; Zansky, Shelley; Holt, Kristin G; Wolpert, Beverly J; Lynch, Michael; Tauxe, Robert; Geissler, Aimee L

    2017-04-21

    Foodborne diseases represent a substantial public health concern in the United States. CDC's Foodborne Diseases Active Surveillance Network (FoodNet) monitors cases reported from 10 U.S. sites* of laboratory-diagnosed infections caused by nine enteric pathogens commonly transmitted through food. This report describes preliminary surveillance data for 2016 on the nine pathogens and changes in incidences compared with 2013-2015. In 2016, FoodNet identified 24,029 infections, 5,512 hospitalizations, and 98 deaths caused by these pathogens. The use of culture-independent diagnostic tests (CIDTs) by clinical laboratories to detect enteric pathogens has been steadily increasing since FoodNet began surveying clinical laboratories in 2010 (1). CIDTs complicate the interpretation of FoodNet surveillance data because pathogen detection could be affected by changes in health care provider behaviors or laboratory testing practices (2). Health care providers might be more likely to order CIDTs because these tests are quicker and easier to use than traditional culture methods, a circumstance that could increase pathogen detection (3). Similarly, pathogen detection could also be increasing as clinical laboratories adopt DNA-based syndromic panels, which include pathogens not often included in routine stool culture (4,5). In addition, CIDTs do not yield isolates, which public health officials rely on to distinguish pathogen subtypes, determine antimicrobial resistance, monitor trends, and detect outbreaks. To obtain isolates for infections identified by CIDTs, laboratories must perform reflex culture † ; if clinical laboratories do not, the burden of culturing falls to state public health laboratories, which might not be able to absorb that burden as the adoption of these tests increases (2). Strategies are needed to preserve access to bacterial isolates for further characterization and to determine the effect of changing trends in testing practices on surveillance.

  17. Investigation of smooth specimen scc test procedures; variations in environment, specimen size, stressing frame, and stress state. [for high strength aluminum alloys

    Science.gov (United States)

    Lifka, B. W.; Sprowls, D. O.; Kelsey, R. A.

    1975-01-01

    The variables studied in the stress-corrosion cracking performance of high strength aluminum alloys were: (1) corrosiveness of the environment, (2) specimen size and stiffness of the stressing system, (3) interpretation of transgranular cracking, and (4) interaction of the state of stress and specimen orientation in a product with an anisotropic grain structure. It was shown that the probability of failure and time to fracture for a specimen loaded in direct tension are influenced by corrosion pattern, the stressing assembly stiffness, and the notch tensile strength of the alloy. Results demonstrate that the combination of a normal tension stress and a shear stress acting on the plane of maximum susceptibility in a product with a highly directional grain cause the greatest tendency for stress-corrosion cracking.

  18. Molecular markers: Implications for cytopathology and specimen collection.

    Science.gov (United States)

    VanderLaan, Paul A

    2015-08-01

    Cytologic specimens obtained through minimally invasive biopsy techniques are increasingly being used as principle diagnostic specimens for tumors arising in multiple sites. The number and scope of ancillary tests performed on these specimens have grown substantially over the past decade, including many molecular markers that not only can aid in formulating accurate and specific diagnoses but also can provide prognostic or therapeutic information to help direct clinical decisions. Thus, the cytopathologist needs to ensure that adequate material is collected and appropriately processed for the study of relevant molecular markers, many of which are specific to tumor site. This brief review covers considerations for effective cytologic specimen collection and processing to ensure diagnostic and testing success. In addition, a general overview is provided of molecular markers pertinent to tumors from a variety of sites. The recognition of these established and emerging molecular markers by cytopathologists is an important step toward realizing the promise of personalized medicine. © 2015 American Cancer Society.

  19. Void coalescence and fracture behavior of notched and un-notched tensile tested specimens in fine grain dual phase steel

    Energy Technology Data Exchange (ETDEWEB)

    Saeidi, N., E-mail: navidsae@gmail.com [Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Ashrafizadeh, F.; Niroumand, B. [Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Forouzan, M.R.; Mohseni mofidi, S. [Department of Mechanical Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Barlat, F. [Materials Mechanics Laboratory (MML), Graduate Institute of Ferrous Technology (GIFT), Pohang University of Science and Technology POSTECH, San 31 Hyoja-dong, Nam-gu, Pohang, Gyeongbuk 790-784 (Korea, Republic of)

    2015-09-17

    Due to growing global concern about the environmental issues, steel developers have been forced by automobile makers to produce more efficient steel grades with high strength to weight ratios along with high crashworthiness performance. In order to find deficiencies of the existing steels and develop superior steel products, detailed understanding of deformation and damage behavior in the existing steels is needed. In the present research, deformation and damage evolution during room temperature uniaxial tensile test of a modern high strength Dual Phase Steel, i.e. DP780, were studied. Detailed scanning electron microscopy (SEM) examination of the microstructures of notched and un-notched tensile fractured specimens revealed that in notched specimen, plastic deformation was concentrated more within the notched region. Therefore, much higher reduction in thickness with a high reduction gradient occurred in this region, In the un-notched specimen, however, plastic deformation was more uniformly distributed in larger parts of the gauge length, and therefore, thickness reduction happened with a lower gradient. Although geometric notch on the specimen did not change the void nucleation and growth mechanisms, the kinetics of these phenomena was influenced. On the other hand, voids linkage mechanism tended to change from void coalescence in the un-notched specimen to void sheeting in the notched specimen. Moreover, three different models developed by Brown & Embury (BM), Thomason and Pardoen were employed to predict the final fracture strain. It was revealed that, BM model showed much more accurate predictions for the studied DP steel in comparison with those of Thomason and Pardoens’ models.

  20. Void coalescence and fracture behavior of notched and un-notched tensile tested specimens in fine grain dual phase steel

    International Nuclear Information System (INIS)

    Saeidi, N.; Ashrafizadeh, F.; Niroumand, B.; Forouzan, M.R.; Mohseni mofidi, S.; Barlat, F.

    2015-01-01

    Due to growing global concern about the environmental issues, steel developers have been forced by automobile makers to produce more efficient steel grades with high strength to weight ratios along with high crashworthiness performance. In order to find deficiencies of the existing steels and develop superior steel products, detailed understanding of deformation and damage behavior in the existing steels is needed. In the present research, deformation and damage evolution during room temperature uniaxial tensile test of a modern high strength Dual Phase Steel, i.e. DP780, were studied. Detailed scanning electron microscopy (SEM) examination of the microstructures of notched and un-notched tensile fractured specimens revealed that in notched specimen, plastic deformation was concentrated more within the notched region. Therefore, much higher reduction in thickness with a high reduction gradient occurred in this region, In the un-notched specimen, however, plastic deformation was more uniformly distributed in larger parts of the gauge length, and therefore, thickness reduction happened with a lower gradient. Although geometric notch on the specimen did not change the void nucleation and growth mechanisms, the kinetics of these phenomena was influenced. On the other hand, voids linkage mechanism tended to change from void coalescence in the un-notched specimen to void sheeting in the notched specimen. Moreover, three different models developed by Brown & Embury (BM), Thomason and Pardoen were employed to predict the final fracture strain. It was revealed that, BM model showed much more accurate predictions for the studied DP steel in comparison with those of Thomason and Pardoens’ models

  1. Crack Propagation on ESE(T) Specimens Strengthened with CFRP Sheets

    DEFF Research Database (Denmark)

    Hansen, Christian Skodborg; Jensen, Peter Holmstrøm; Dyrelund, Jens

    2009-01-01

    In this paper fatigue tests on side notched steel test specimens strengthened with adhesive bonded fibre reinforced polymer (FRP) sheets are presented. The specimens are subject to crack growth both in the steel and bond line. Influence of the load ratio and initial crack length on the overall...

  2. Fracture Toughness Round Robin Test International in pressure tube materials

    International Nuclear Information System (INIS)

    Villagarcia, M.P.; Liendo, M.F.

    1993-01-01

    Part of the pressure tubes surveillance program of CANDU type reactors is to determine the fracture toughness using a special fracture specimen and test procedure. Atomic Energy of Canada Limited decided to hold a Round Robin Test International and 9 laboratories participated worldwide in which several pressure tube materials were selected: Zircaloy-2, Zr-2.5%Nb cold worked and Zr-2.5%Nb heat treated. The small specimens used held back the thickness and curvature of the tube. J-R curves at room temperature were obtained and the crack extension values were determined by electrical potential drop techniques. These values were compared with results generated from other laboratories and a bid scatter was founded. It could be due to slight variations in the test method or inhomogeneity of the materials and a statistical study must be done to see if there is any pattern. The next step for the Round Robin Test would be to make some modifications in the test method in order to reduce the scatter. (Author)

  3. Fracture assessment of HSST Plate 14 shallow-flaw cruciform bend specimens tested under biaxial loading conditions

    Energy Technology Data Exchange (ETDEWEB)

    Bass, B.R.; McAfee, W.J.; Williams, P.T.; Pennell, W.E.

    1998-06-01

    A technology to determine shallow-flaw fracture toughness of reactor pressure vessel (RPV) steels is being developed for application to the safety assessment of RPVs containing postulated shallow surface flaws. Matrices of cruciform beam tests were developed to investigate and quantify the effects of temperature, biaxial loading, and specimen size on fracture initiation toughness of two-dimensional (constant depth), shallow, surface flaws. The cruciform beam specimens were developed at Oak Ridge National Laboratory (ORNL) to introduce a far-field, out-of-plane biaxial stress component in the test section that approximates the nonlinear stresses resulting from pressurized-thermal-shock or pressure-temperature loading of an RPV. Tests were conducted under biaxial load ratios ranging from uniaxial to equibiaxial. These tests demonstrated that biaxial loading can have a pronounced effect on shallow-flaw fracture toughness in the lower transition temperature region for an RPV material. The cruciform fracture toughness data were used to evaluate fracture methodologies for predicting the observed effects of biaxial loading on shallow-flaw fracture toughness. Initial emphasis was placed on assessment of stress-based methodologies, namely, the J-Q formulation, the Dodds-Anderson toughness scaling model, and the Weibull approach. Applications of these methodologies based on the hydrostatic stress fracture criterion indicated an effect of loading-biaxiality on fracture toughness; the conventional maximum principal stress criterion indicated no effect. A three-parameter Weibull model based on the hydrostatic stress criterion is shown to correlate the experimentally observed biaxial effect on cleavage fracture toughness by providing a scaling mechanism between uniaxial and biaxial loading states.

  4. Effect of specimen geometry on the variability in fatigue crack growth rate

    International Nuclear Information System (INIS)

    Tsuji, Hirokazu; Nakajima, Hajime; Kondo, Tatsuo

    1982-02-01

    Fatigue crack growth tests on SA 533 grade B class 1 steel were conducted in air with both contoured double cantilever beam (CDCB) specimens and compact-tension (CT) specimens for comparison, which corresponded to the ΔK constant and ΔK increasing fatigue tests respectively. The variability of the measured values was examined statistically, and possible sources of the determined variability were discussed. The variability in the ΔK increasing fatigue tests with the CT specimens was found to be substantially greater than that in the ΔK constant fatigue tests with the CDCB specimens employed in the present study. In addition, the width of the scatter as well as in the degree of deviation from the expected linearity in da/dN versus ΔK plots were found to be varied depending on the level of ΔK in the CT specimen. Based on the results, a conclusion was drawn that constant ΔK type tests should be preferred in the tests where accuracy and reproducibility of crack growth rate measurement was of particular importance. (author)

  5. Detection of adenovirus in nasopharyngeal specimens by radioactive and nonradioactive DNA probes

    International Nuclear Information System (INIS)

    Hyypiae, T.

    1985-01-01

    The presence of adenovirus DNA in clinical specimens was analyzed by nucleic acid hybridization assays by both radioactive and enzymatic detection systems. The sensitivity of the hybridization tests was in the range of 10 to 100 pg of homologous adenovirus DNA. Minimal background was noticed with unrelated viral and nonviral DNA. Twenty-four nasopharyngeal mucus aspirate specimens, collected from children with acute respiratory infection, were assayed in the hybridization tests and also by an enzyme immunoassay for adenovirus hexon antigen which was used as a reference test. Sixteen specimens positive by the enzyme immunoassay also were positive in the two nucleic acid hybridization tests, and the remaining eight specimens were negative in all of the tests. The results indicate that nucleid acid hybridization tests with both radioactive and nonradioactive probes can be used for diagnosis of microbial infections

  6. Trends in performance of the National Measles Case-Based Surveillance System, Ministry of Health and Child Welfare, Zimbabwe (1999 - 2008)

    Science.gov (United States)

    Choto, Regis; Chadambuka, Addmore; Shambira, Gerald; Gombe, Notion; Tshimanga, Mufuta; Midzi, Stanley; Mberikunashe, Joseph

    2012-01-01

    Introduction Since adoption of the measles case-based surveillance system in Zimbabwe in 1998, data has been routinely collected at all levels of the health delivery system and sent to national level with little or no documented evidence of use to identify risky populations, monitor impact of interventions and measure progress towards achieving measles elimination. We analysed this data to determine trends in the national measles case-based surveillance system (NMCBSS). Methods A retrospective record review of the NMCBSS dataset for period 1999 –2008 was conducted, assessing trends in proportions of investigated cases; timeliness and nature of specimens received at laboratory; timeliness of feedback of serology results, proportion of cases confirmed as measles and national annualized rates of investigation. Comparisons with WHO performance indicators were done. The secondary data analysis was done in Excel and Epi-Info statistical software. Results Cumulatively 4994 suspected cases were reported and investigated between 1999 and 2008. Reported suspected and confirmed measles cases declined from 24, 5% and 5.9% respectively in 2000 to 3.9% and 1.0% respectively in 2008. Proportion of cases with blood specimens collected and proportion reaching laboratory timely increased from 83% and 65% respectively in 1999, to 100% and 82% respectively in 2008. Proportion of specimens arriving at laboratory in good condition improved from 65% in 2004 to 94% in 2008 while timeliness of feedback of serology results improved from 4% in 2004 to 65% in 2008. Sensitivity of the NMCBSS however has been weakening, declining from 9.04 cases investigated per 100 000 population per year in 2000 to 1.58 cases/100 000/year in 2008. Conclusion The NMCBSS improved in quality, timeliness and feedback of laboratory results of specimens sent for investigation, but its sensitivity declined mainly due to reduced capacity to detect and confirm measles cases. We recommend training staff on active

  7. Freeze-Thaw Cycle Test on Basalt, Diorite and Tuff Specimens with the Simulated Ground Temperature of Antarctica

    Science.gov (United States)

    Park, J.; Hyun, C.; Cho, H.; Park, H.

    2010-12-01

    Physical weathering caused by freeze-thaw action in cold regions was simulated with artificial weathering simulator in laboratory. Physical weathering of rock in cold regions usually depends on the temperature, rock type and moisture content. Then these three variables were considered in this study. The laboratory freeze-thaw tests were conducted on the three types of rocks, e.g. diorite, basalt and tuff, which are the major rock types around Sejong Station, King George Island, Antarctica. Nine core samples composed of three samples from each rock type were prepared in NX core, and 50 cycles of freeze-thaw test was carried out under dried and saturated water conditions. In this study, the physical weathering of rocks was investigated after each 10 cycles by measuring P-wave velocity, bulk density, effective porosity, Schmidt hardness and uniaxial compression strength(UCS). The experimental result of the diorite and the tuff specimens showed that P-wave velocity, bulk density, effective porosity, Schmidt hardness and UCS were gradually decreased as weathering progresses, but the result of the basalt specimens did not show typical trends due to the characteristics of irregular pore distribution and various pore sizes. Scanning electron microscopy(SEM) photographs of diorite, basalt and tuff specimens weathered in dried and saturated conditions were also acquired to investigate the role of water during physical weathering processes. The number and size of microcracks were increased as weathering progresses. This work was supported by the National Research Foundation of Korea(NRF) Grant(NRF-2010-0027753).

  8. Utility of molecular tests in cytopathology

    Directory of Open Access Journals (Sweden)

    Arthur David Somoza

    2014-01-01

    Full Text Available With the popularity of interventional radiology, diagnostic material obtained can be limited requiring critical decisions on making the best use of it. Molecular testing using nanogram amounts of tissue can add useful diagnostic information by improving sensitivity and/or specificity of the diagnosis. This review examines the use of molecular tests in cervical cytology, "indeterminate" thyroid cytology specimens, pancreatic cyst fluid, urinary tract and pulmonary adenocarcinoma cytologic material. Molecular human papillomavirus (HPV testing combined with cervical cytology increases sensitivity of detection of high grade lesions. In cytologically negative cases, the HPV negative predictive value endorses longer screening intervals. With the high prevalence of benign thyroid nodules, cytology plays a vital role in screening. However, 10-40% of the specimens obtained are cytologically indeterminate. Molecular analysis of these specimens can predict the malignant risk in these cases. Increased detection of pancreatic cysts has necessitated accurate pre-operative diagnosis delineating non-mucinous from mucinous cysts, which have a potential for progression to adenocarcinoma. Multimodal diagnosis of pancreatic cysts and molecular analysis help to clarify neoplastic risk; and in cases of limited fluid, may be the only available diagnostic information. Urothelial carcinoma (UC of the bladder, a common cancer with frequent recurrences, requires lifelong surveillance. The UroVysion ™ test kit can increase the sensitivity of detection of UC especially in cases of residual/recurrent carcinoma after therapy. Subsets of lung adenocarcinomas are now commonly targeted by therapies based on molecular mutation results of epidermal growth factor receptor, KRAS or echinoderm microtubule-associated protein-like 4-anaplastic lymphoma kinase re-arrangements. The move toward standardization of reporting of cytology specimens commencing with cervical smears and more

  9. Small specimen technique for assessing mechanical properties of metallic components

    Energy Technology Data Exchange (ETDEWEB)

    Lobo, Raquel M.; Andrade, Arnaldo H.P.; Morcelli, Aparecido E., E-mail: rmlobo@ipen.br, E-mail: morcelliae@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    Small Punch Test (SPT) is one of the most promising techniques of small specimen test, which was originally applied in testing of irradiated materials in nuclear engineering. Then it was introduced to other fields as an almost nondestructive method to measure the local mechanical properties that are difficult to be obtained using conventional mechanical tests. Most studies to date are focused on metallic materials, although SPT applications are recently spreading to other materials. The small punch test (SPT) employs small-sized specimens (for example, samples measuring 8 mm in diameter and 0.5 mm thick). The specimen is firmly clamped between two circular dies and is bi-axially strained until failure into a circular hole using a hemispherical punch. The 'load-punch displacement' record can be used to estimate the yield strength, the ultimate tensile strength, the tensile elongation, and the temperature of the ductile-to-brittle transition. Recently, some researchers are working on the use of miniature notched or pre-cracked specimens (denoted as p-SPT) to validate its geometry and dimensions for obtaining the fracture properties of metallic materials. In a first approach, the technique makes it possible to convert primary experimental data into conventional mechanical properties of a massive specimen. In this paper a comprehensive review of the different STP applications is presented with the aim of clarifying its usefulness. (author)

  10. Small specimen technique for assessing mechanical properties of metallic components

    International Nuclear Information System (INIS)

    Lobo, Raquel M.; Andrade, Arnaldo H.P.; Morcelli, Aparecido E.

    2017-01-01

    Small Punch Test (SPT) is one of the most promising techniques of small specimen test, which was originally applied in testing of irradiated materials in nuclear engineering. Then it was introduced to other fields as an almost nondestructive method to measure the local mechanical properties that are difficult to be obtained using conventional mechanical tests. Most studies to date are focused on metallic materials, although SPT applications are recently spreading to other materials. The small punch test (SPT) employs small-sized specimens (for example, samples measuring 8 mm in diameter and 0.5 mm thick). The specimen is firmly clamped between two circular dies and is bi-axially strained until failure into a circular hole using a hemispherical punch. The 'load-punch displacement' record can be used to estimate the yield strength, the ultimate tensile strength, the tensile elongation, and the temperature of the ductile-to-brittle transition. Recently, some researchers are working on the use of miniature notched or pre-cracked specimens (denoted as p-SPT) to validate its geometry and dimensions for obtaining the fracture properties of metallic materials. In a first approach, the technique makes it possible to convert primary experimental data into conventional mechanical properties of a massive specimen. In this paper a comprehensive review of the different STP applications is presented with the aim of clarifying its usefulness. (author)

  11. [Surveillance system for adverse events following immunization against yellow fever in Burkina Faso in 2008. Good practice recommendations].

    Science.gov (United States)

    Yaméogo, T M; Breugelmans, J G; Kambou, J L; Badolo, O; Tiendrebéogo, S; Traoré, E; Avokey, F; Yactayo, S

    2009-08-01

    -duty hospital staff were interviewed. The Ministry of Health appointed an 11-member National Expert Committee (NEC) to investigate and judge the status of reported cases. After eliminating coincidental events, program errors, and undetermined cases, vaccination was established as the suspected cause. Suspected cases were classified as viserotrophic or neurotrophic AEFI and recorded as probable cases pending confirmation by virologic studies. An AEFI center with a duly mandated coordinator was designated to coordinate the activities of the different teams involved and to serve as an interface for the expert committee. Detection and investigation teams were formed at each of the hospital locations. A national laboratory as well as an international virology laboratory were designated as reference centers for performance of further testing. Results. Between November 28, 2008, and December 9, 2008, a total 7,566,218 people (aged 9 months and older) excluding pregnant women, critically ill patients, and individuals allergic to eggs, were immunized in 37 of the 63 districts in Burkina Faso. Administrative vaccination coverage was 102.3%. Systematic line-listing at the 3 hospital centers accounted for most of the suspected serious AEFIs identified from reported cases. During the AEFI surveillance period, the NEC met once a week to discuss the suspected serious AEFI. Some cases were excluded and others were designated for further testing. At least one biological specimen was available for all retained cases. Each case benefited from laboratory testing to achieve differential clinical diagnosis as well as from virological testing (results pending). Conclusion. Experiences in Burkina Faso demonstrates the value of active surveillance and of systematic line listing. However, the duration of case investigation and data management was at least six months. To improve AEFI surveillance in future campaigns, several measures can be recommended. Planning should begin well in advance with

  12. Surveillance for West Nile virus in clinic-admitted raptors, Colorado.

    Science.gov (United States)

    Nemeth, Nicole; Kratz, Gail; Edwards, Eric; Scherpelz, Judy; Bowen, Richard; Komar, Nicholas

    2007-02-01

    In 2005, 13.5% of clinic-admitted raptors in northern Colorado tested positive for West Nile virus (WNV). Clinic-admitted-raptor surveillance detected WNV activity nearly 14 weeks earlier than other surveillance systems. WNV surveillance using live raptor admissions to rehabilitation clinics may offer a novel surveillance method and should be considered along with other techniques already in use.

  13. Linear Array Ultrasonic Test Results from Alkali-Silica Reaction (ASR) Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Khazanovich, Dr. Lev [Univ. of Minnesota, Minneapolis, MN (United States); Salles, Lucio [Univ. of Minnesota, Minneapolis, MN (United States)

    2016-04-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the various nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations.This report presents results of the ultrasound evaluation of four concrete slabs with varying levels of ASR damage present. This included an investigation of the experimental results, as well as a supplemental simulation considering the effect of ASR damage by elasto-dynamic wave propagation using a finite integration technique method. It was found that the Hilbert Transform Indicator (HTI), developed for quantification of freeze/thaw damage in concrete structures, could also be successfully utilized for quantification of ASR damage. internal microstructure flaws, and reinforcement locations.

  14. Illustration of the WPS benefit through BATMAN test series: Tests on large specimens under WPS loading configurations

    International Nuclear Information System (INIS)

    Yuritzinn, T.; Ferry, L.; Chapuliot, S.; Mongabure, P.; Moinereau, D.; Dahl, A.; Gilles, P.

    2008-01-01

    To study the effects of warm pre-stressing on the toughness of reactor pressure vessel steel, the 'Commissariat a l Energie Atomique', in collaboration with 'Electricite de France' and AREVA-NP, has made a study combining modeling and a series of experiments on large specimens submitted to a thermal shock or isothermal cooling. The tests were made on 18MND5 ferritic steel bars, containing a short or large fatigue pre-crack. The effect of 'warm pre-stressing' was confirmed, in the two cases of a fast thermal shock creating a gradient across the thickness of the bar and for gradual uniform cooling. In both cases, no propagation was observed during the thermal transient. Fracture occurred under low temperature conditions, at the end of the test when the tensile load was increased. The failure loads recorded were substantially higher than during pre-stressing. To illustrate the benefit of the WPS effect, numerical interpretations were performed using either global approach or local approach criteria. WPS effect and capability of models to predict it were then clearly shown. (authors)

  15. Laser surveillance system (LASSY)

    International Nuclear Information System (INIS)

    Boeck, H.

    1991-09-01

    Laser Surveillance System (LASSY) is a beam of laser light which scans a plane above the water or under-water in a spent-fuel pond. The system can detect different objects and estimates its coordinates and distance as well. LASSY can operate in stand-alone configuration or in combination with a video surveillance to trigger signal to a videorecorder. The recorded information on LASSY computer's disk comprises date, time, start and stop angle of detected alarm, the size of the disturbance indicated in number of deviated points and some other information. The information given by the laser system cannot be fully substituted by TV camera pictures since the scanning beam creates a horizontal surveillance plan. The engineered prototype laser system long-term field test has been carried out in Soluggia (Italy) and has shown its feasibility and reliability under the conditions of real spent fuel storage pond. The verification of the alarm table on the LASSY computer with the recorded video pictures of TV surveillance system confirmed that all alarm situations have been detected. 5 refs

  16. Preliminary investigation of candidate specimens for the Egyptian environmental specimen bank

    International Nuclear Information System (INIS)

    Shawky, S.; Amer, H.; Schladot, J.D.; Ostapczuk, P.; Emons, H.; Abou El-Nour, F.

    2000-01-01

    In the frame of establishing an environmental monitoring program related to environmental specimen banking in egypt, some candidate specimens from the aquatic environment (Fish muscle, fish liver; mussels) were investigated. The selection of specimens and sampling sites is described. Specimens are chemically characterised with respect to some major and trace elements and the results are compared with data obtained from comparable specimens collected in aquatic ecosystems of germany

  17. Material Models to Study the Bauschinger Effect on an Aluminum Shear Test Specimen

    International Nuclear Information System (INIS)

    Cardoso, Rui P. R.; Gracio, Jose J.; Yoon, Jeong-Whan

    2007-01-01

    Sheet metal forming processes generally involve complex loadings and nonlinear material models. Combinations of drawing, re-drawing and/or reverse drawing operations commonly induce cyclic loads with non-proportional strain paths, leading to Bauschinger effects that can not be predicted by conventional isotropic hardening laws. In order to properly represent this effect, it is also required to accommodate an appropriate kinematic hardening model along with an anisotropic yield function. In this work, two different approaches will be used to predict the Bauschinger effect for an Aluminum shear test specimen: the rate dependent crystal plasticity model and a new combined isotropic/kinematic hardening model based on the two yield surfaces approach (loading and boundary yield surfaces), as recently proposed

  18. Experimental and Numerical Investigations on Feasibility and Validity of Prismatic Rock Specimen in SHPB

    Directory of Open Access Journals (Sweden)

    Xibing Li

    2016-01-01

    Full Text Available The paper presents experimental and numerical studies on the feasibility and validity of using prismatic rock specimens in split Hopkinson pressure bar (SHPB test. Firstly, the experimental tests are conducted to evaluate the stress and strain uniformity in the prismatic specimens during impact loading. The stress analysis at the ends of the specimen shows that stress equilibrium can be achieved after about three wave reflections in the specimen, and the balance can be well maintained for a certain time after peak stress. The strain analysis reveals that the prismatic specimen deforms uniformly during the dynamic loading period. Secondly, numerical simulation is performed to further verify the stress and strain uniformity in the prismatic specimen in SHPB test. It indicates that the stress equilibrium can be achieved in prismatic specimen despite a certain degree of stress concentration at the corners. The comparative experiments demonstrate that the change of specimen shape has no significant effect on dynamic responses and failure patterns of the specimen. Finally, a dynamic crack propagation test is presented to show the application of the present work in studying fracturing mechanisms under dynamic loading.

  19. Biological specimens for community-based surveillance studies: Method of recruitment matters

    Directory of Open Access Journals (Sweden)

    Brenda L. Coleman

    2011-12-01

    Full Text Available Studies requiring the collection of biological specimens are often difficult to perform and costly. We compare face-to-face and telephone interviews to determine which is more effective for return of self-collected rectal swabs from subjects living in rural and semi-rural areas of Ontario, Canada. People interviewed face-to-face in 2006-2007 were asked to provide a rectal swab while the interviewer waited. Those interviewed by telephone were sent a package and asked to return the swab by mail, with one follow-up reminder call. Telephone interviewing resulted in a higher response rate for the completion of household and individual-level questionnaires. However, face-to-face interviews resulted in a significantly higher proportion of interviewees who returned swabs making the participation rate higher for this mode of contact (33.7 versus 25.0 percent. Using multivariable logistic regression, higher rates of rectal swab return were associated with face-to-face interviewing while adjusting for the impact of household size and respondent age and sex. For studies requiring the submission of intimate biological samples, face-to-face interviews can be expected to provide a higher rate of return than telephone interviews.

  20. Detection of cervical precancerous lesions with Aptima HPV assays using SurePath preservative fluid specimens

    Directory of Open Access Journals (Sweden)

    Max Chernesky

    2017-06-01

    Full Text Available SurePath specimens from women referred to colposcopy were treated with Aptima Transfer Solution (ATS before testing in Aptima HPV (AHPV and Aptima HPV 16, 18/45 (AHPV-GT assays. Untreated SurePath specimens were tested with the cobas HPV test. PreservCyt specimens were assessed for cytology and tested with AHPV. High-grade cervical intraepithelial neoplasia lesions served as the reference standard. Excellent agreement (95.5%; k=0.91 was observed for ATS-treated SurePath specimens between Tigris and Panther systems and between the PreservCyt and ATS-treated SurePath specimens (91.1%, k=0.81 with the AHPV assay on Tigris. Agreement between the AHPV and cobas assays with SurePath specimens was substantial (89.9%, k=0.80. AHPV sensitivity for CIN2+(n=147 was 91.2% for SurePath and PreservCyt. Cobas HPV sensitivity was 93.9% for SurePath specimens. AHPV testing of SurePath specimens was more specific (59.4% than cobas (54.7% (p<0.001. Detection and genotyping showed similar absolute and relative risks. ATS-treated SurePath specimens tested with AHPV and AHPV-GT assays showed similar performance with greater specificity than cobas HPV on SurePath specimens. Similar overall results were seen using a CIN3 disease endpoint. Keywords: Human papillomavirus, SurePath, PreservCyt, Cervical intraepithelial neoplasia, CIN2+, Aptima transfer solution (ATS

  1. Vascular access surveillance: case study of a false paradigm.

    Science.gov (United States)

    Paulson, William D; Moist, Louise; Lok, Charmaine E

    2013-01-01

    The hemodialysis vascular access surveillance controversy provides a case study of how enthusiasm for a new test or treatment can lead to adoption of a false paradigm. Paradigms are the beliefs and assumptions shared by those in a field of knowledge, and are commonly included in clinical practice guidelines. The guidelines of the National Kidney Foundation Kidney Disease Outcomes Quality Initiative recommend that arteriovenous vascular accesses undergo routine surveillance for detection and correction of stenosis. This recommendation is based on the paradigm that surveillance of access blood flow or dialysis venous pressure combined with correction of stenosis improves access outcomes. However, the quality of evidence that supports this paradigm has been widely criticized. We tested the validity of the surveillance paradigm by applying World Health Organization (WHO) criteria for evaluating screening tests to a literature review of published vascular access studies. These criteria include four components: undesired condition, screening test, intervention, and desired outcome. The WHO criteria show that surveillance as currently practiced fails all four components and provides little or no significant benefit, suggesting that surveillance is a false paradigm. Once a paradigm is established, however, challenges to its validity are usually resisted even as new evidence indicates the paradigm is not valid. Thus, it is paramount to apply rigorous criteria when developing guidelines. Regulators may help promote needed changes in paradigms when cost and safety considerations coincide. © 2013 Wiley Periodicals, Inc.

  2. Technical justifications for the tests and criteria in the waste form technical position appendix on cement stabilization

    International Nuclear Information System (INIS)

    Siskind, B.; Cowgill, M.G.

    1992-01-01

    As part of its technical assistance to the Nuclear Regulatory Commission (NRC), Brookhaven National Laboratory (BNL) developed a background document for the cement stabilization appendix, Appendix A, to Rev. 1 of the Technical Position on Waste Form (TP). Here we present an overview of this background document, which provides technical justification for the stability tests to be performed on cement-stabilized waste forms and for the criteria posed in each test, especially for those tests which have been changed from their counterparts in the May 1983 Rev. 0 TP. We address guidelines for procedures from Appendix A which are considered in less detail or not at all in the Rev. 0 of the TP, namely, qualification specimen preparation (mixing, curing, storage), statistical sampling and analysis, process control program specimen preparation and examination, and surveillance specimens. For each waste form qualification test, criterion or procedural guidelines, we consider the reason for its inclusion in Appendix A, the changes from Rev. 0 of the TP (if applicable), and a discussion of the justification or rationale for these changes

  3. Technical justifications for the tests and criteria in the waste form Technical position appendix on cement stabilization

    International Nuclear Information System (INIS)

    Siskind, B.; Cowgill, M.G.

    1992-01-01

    As part of its technical assistance to the Nuclear Regulatory Commission (NRC), Brookhaven National Laboratory (BNL) developed a background document for the cement stabilization appendix. Appendix A, to Rev. 1 of the Technical Position on Waste Form (TP). Here we present an overview of this background document, which provides technical justification for the stability tests to be performed on cement-stabilized waste forms and for the criteria posed in each test) especially for those tests which have been changed from their counterparts in the May 1983 Rev. 0 TP. We address guidelines for procedures from Appendix A which are considered in less detail or not at all in the Rev. 0 of the TP, namely, qualification specimen preparation (mixing, curing, storage), statistical sampling and analysis, process control program specimen preparation and examination, and surveillance specimens. For each waste form qualification test, criterion or procedural guideline, we consider the reason for its inclusion in Appendix A, the changes from Rev. 0 of the TP (if applicable), and a discussion of the justification or rationale for these changes. (author)

  4. A point-of-care test for measles diagnosis: detection of measles-specific IgM antibodies and viral nucleic acid.

    Science.gov (United States)

    Warrener, Lenesha; Slibinskas, Rimantas; Chua, Kaw Bing; Nigatu, Wondatir; Brown, Kevin E; Sasnauskas, Kestutis; Samuel, Dhanraj; Brown, David

    2011-09-01

    To evaluate the performance of a newly developed point-of-care test (POCT) for the detection of measles-specific IgM antibodies in serum and oral fluid specimens and to assess if measles virus nucleic acid could be recovered from used POCT strips. The POCT was used to test 170 serum specimens collected through measles surveillance or vaccination programmes in Ethiopia, Malaysia and the Russian Federation: 69 were positive for measles immunoglobulin M (IgM) antibodies, 74 were positive for rubella IgM antibodies and 7 were positive for both. Also tested were 282 oral fluid specimens from the measles, mumps and rubella (MMR) surveillance programme of the United Kingdom of Great Britain and Northern Ireland. The Microimmune measles IgM capture enzyme immunoassay was the gold standard for comparison. A panel of 24 oral fluids was used to investigate if measles virus haemagglutinin (H) and nucleocapsid (N) genes could be amplified by polymerase chain reaction directly from used POCT strips. With serum POCT showed a sensitivity and specificity of 90.8% (69/76) and 93.6% (88/94), respectively; with oral fluids, sensitivity and specificity were 90.0% (63/70) and 96.2% (200/208), respectively. Both H and N genes were reliably detected in POCT strips and the N genes could be sequenced for genotyping. Measles virus genes could be recovered from POCT strips after storage for 5 weeks at 20-25 °C. The POCT has the sensitivity and specificity required of a field-based test for measles diagnosis. However, its role in global measles control programmes requires further evaluation.

  5. Demonstration of Laser Cutting System for Tube Specimen

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Y. G.; Kim, G. S.; Heo, G. S.; Baik, S. J.; Kim, H. M.; Ahn, S. B. [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated fuel cladding and components interrupted the applying the electric current during the processing. However, it was found that the mechanical testing data of the irradiated specimens with removal of oxide layer was less reliable than the specimens with oxide layer . The laser cutting system using Nd:YAG with fiber optic beam delivery has great potential in material processing applications of the irradiated fuel cladding and components due to non-contact process. Thus, the oxide layer doesn't interrupt the fabrication process during the laser cutting system. In the present study, the laser cutting system was designed to fabricate the mechanical testing specimens from the unirradiated fuel cladding with and without oxide. The feasibility of the laser cutting system was demonstrated for the fabrication of various types of unirradiated specimens. The effect of surface oxide layer was also investigated for machining process of the zirlo fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer. Based on the feasibility studies and demonstration, the design of the laser cutting machine for fully or partially automatic and remotely operable system will be proposed and made.

  6. Occupational health surveillance: Pulmonary function testing in emergency responders

    Directory of Open Access Journals (Sweden)

    James D McCluskey

    2014-01-01

    Full Text Available Emergency responders may be exposed to a variety of fumes, gases, and particulates during the course of their job that can affect pulmonary function (PF and require the use of respiratory protection. This investigation used occupational health monitoring examination data to characterize PF in a population currently employed as emergency responders. PF tests for workers who required health examinations to ensure fitness for continued respirator use were compared to the National Health and Nutrition Examination Survey (NHANES III Raw Spirometry database to determine if decreased PF was associated with employment as an emergency responder. The results of this research indicated that the emergency responders experienced a modest, but statistically significant, increase in forced expiratory volume in 1 second (FEV1 and forced vital capacity (FVC mean values over the NHANES III population in both total and stratified analyses, including stratification by age, gender, height, and smoking history. Results are likely due to a combination of effectively controlled exposures in the workplace, and the healthy worker effect among long-term workers. PF testing required by the Occupational and Safety Health Administration (OSHA has substantial utility for conducting occupational surveillance at the population level. In this investigation, we were able to quickly evaluate if abnormal PF existed in an industrial sector known to have exposures that, when uncontrolled, can lead to PF impairment.

  7. Surveillance

    DEFF Research Database (Denmark)

    Albrechtslund, Anders; Coeckelbergh, Mark; Matzner, Tobias

    Studying surveillance involves raising questions about the very nature of concepts such as information, technology, identity, space and power. Besides the maybe all too obvious ethical issues often discussed with regard to surveillance, there are several other angles and approaches that we should...... like to encourage. Therefore, our panel will focus on the philosophical, yet non-ethical issues of surveillance in order to stimulate an intense debate with the audience on the ethical implications of our enquiries. We also hope to provide a broader and deeper understanding of surveillance....

  8. Poliomyelitis surveillance: the model used in India for polio eradication.

    Science.gov (United States)

    Banerjee, K.; Hlady, W. G.; Andrus, J. K.; Sarkar, S.; Fitzsimmons, J.; Abeykoon, P.

    2000-01-01

    Poliomyelitis surveillance in India previously involved the passive reporting of clinically suspected cases. The capacity for detecting the disease was limited because there was no surveillance of acute flaccid paralysis (AFP). In October 1997, 59 specially trained Surveillance Medical Officers were deployed throughout the country to establish active AFP surveillance; 11,533 units were created to report weekly on the occurrence of AFP cases at the district, state and national levels; timely case investigation and the collection of stool specimens from AFP cases was undertaken; linkages were made to support the polio laboratory network; and extensive training of government counterparts of the Surveillance Medical Officers was conducted. Data reported at the national level are analysed and distributed weekly. Annualized rates of non-polio AFP increased from 0.22 per 100,000 children aged under 15 years in 1997 to 1.39 per 100,000 in 1999. The proportion of cases with two adequate stools collected within two weeks of the onset of paralysis increased from 34% in 1997 to 68% in 1999. The number of polio cases associated with the isolation of wild poliovirus decreased from 211 in the first quarter of 1998 to 77 in the first quarter of 1999. Widespread transmission of wild poliovirus types 1 and 3 persists throughout the country; type 2 occurs only in Bihar and Uttar Pradesh. In order to achieve polio eradication in India during 2000, extra national immunization days and house-to-house mopping-up rounds should be organized. PMID:10812728

  9. Prediction of multiaxial fatigue life for notched specimens of titanium alloy TC4

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Z. R.; Li, Z. X. [Southeast University, Nanjing (China); Hu, X. T.; Song, Y. D. [Nanjing University, Nanjing (China)

    2016-05-15

    Both the proportional and nonproportional multiaxial fatigue tests were conducted on two kinds of notched specimens of titanium alloy TC4. The multiaxial fatigue critical area of notched specimen is considered as the location experiencing the maximum damage. It is unsatisfactory to predict the multiaxial fatigue life with the local stress and strain in the fatigue critical area. The critical distance concepts are employed in the multiaxial life prediction method for notched specimens. The proposed method was checked by the test data of TC4 notched specimens. The prediction results are almost within a factor of three scatter band of the test results.

  10. Patient safety in the clinical laboratory: a longitudinal analysis of specimen identification errors.

    Science.gov (United States)

    Wagar, Elizabeth A; Tamashiro, Lorraine; Yasin, Bushra; Hilborne, Lee; Bruckner, David A

    2006-11-01

    Patient safety is an increasingly visible and important mission for clinical laboratories. Attention to improving processes related to patient identification and specimen labeling is being paid by accreditation and regulatory organizations because errors in these areas that jeopardize patient safety are common and avoidable through improvement in the total testing process. To assess patient identification and specimen labeling improvement after multiple implementation projects using longitudinal statistical tools. Specimen errors were categorized by a multidisciplinary health care team. Patient identification errors were grouped into 3 categories: (1) specimen/requisition mismatch, (2) unlabeled specimens, and (3) mislabeled specimens. Specimens with these types of identification errors were compared preimplementation and postimplementation for 3 patient safety projects: (1) reorganization of phlebotomy (4 months); (2) introduction of an electronic event reporting system (10 months); and (3) activation of an automated processing system (14 months) for a 24-month period, using trend analysis and Student t test statistics. Of 16,632 total specimen errors, mislabeled specimens, requisition mismatches, and unlabeled specimens represented 1.0%, 6.3%, and 4.6% of errors, respectively. Student t test showed a significant decrease in the most serious error, mislabeled specimens (P patient safety projects. Trend analysis demonstrated decreases in all 3 error types for 26 months. Applying performance-improvement strategies that focus longitudinally on specimen labeling errors can significantly reduce errors, therefore improving patient safety. This is an important area in which laboratory professionals, working in interdisciplinary teams, can improve safety and outcomes of care.

  11. Horizontal loading test by whole model specimen simulating inner concrete structure of PWR type nuclear power plant

    International Nuclear Information System (INIS)

    Furuya, Noriyuki; Sekine, Masataka; Kimura, Kozo; Yamaguchi, Yoshihiro; Yamaguchi, Tsuneo; Takeda, Toshikazu

    1985-01-01

    The Nuclear Power Engineering Test Center has performed a horizontal loading test by a whole model specimen simulating the inner concrete structure of a PWR type nuclear power plant in order to investigate restoring force characteristics of reactor buildings. This report describes the results of examination of applicability to the test results of analysis methods based on elastic theory. The analysis results of elastic stiffness, concrete cracking load, rebar yielding loads and ultimate strength were compared with the test results. According to this examination, it is recognized that even these analysis methods based on elastic theory are comparatively effective for analysis of an inner concrete structure of fairly complex configuration, although there are limits of the scope of applicability. (author)

  12. A Study on Mechanical behavior of Tensile Specimen Fabricated by Laser Cutting

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Y. G.; Kim, G. S.; Baik, S. J.; Baek, S. Y. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The mechanical testing data are required for the assessment of dry storage of the spent nuclear fuel. Laser cutting system could be useful tools for material processing such as cutting in radioactive environment due to non-contact nature, ease in handling and the laser cutting process is most advantageous, offering the narrow kerf width and heat affected zone by using small beam spot diameter. The feasibility of the laser cutting system was demonstrated for the fabrication of various types of the unirradiated cladding with and without oxide layer on the specimens. In the present study, the dimensional measurement and tensile test were conducted to investigate the mechanical behavior of the axial tensile test specimens depending on the material processing methods in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser cutting system was used to fabricate the tensile test specimens, and the mechanical behavior was investigated using the dimensional measurement and tensile test. It was shown that the laser beam machining could be a useful tool to fabricate the specimens and this technique will be developed for the fabrication of various types of irradiated specimens in a hotcell.

  13. A Study on Mechanical behavior of Tensile Specimen Fabricated by Laser Cutting

    International Nuclear Information System (INIS)

    Jin, Y. G.; Kim, G. S.; Baik, S. J.; Baek, S. Y.

    2016-01-01

    The mechanical testing data are required for the assessment of dry storage of the spent nuclear fuel. Laser cutting system could be useful tools for material processing such as cutting in radioactive environment due to non-contact nature, ease in handling and the laser cutting process is most advantageous, offering the narrow kerf width and heat affected zone by using small beam spot diameter. The feasibility of the laser cutting system was demonstrated for the fabrication of various types of the unirradiated cladding with and without oxide layer on the specimens. In the present study, the dimensional measurement and tensile test were conducted to investigate the mechanical behavior of the axial tensile test specimens depending on the material processing methods in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser cutting system was used to fabricate the tensile test specimens, and the mechanical behavior was investigated using the dimensional measurement and tensile test. It was shown that the laser beam machining could be a useful tool to fabricate the specimens and this technique will be developed for the fabrication of various types of irradiated specimens in a hotcell

  14. Evaluation of surveillance case definition in the diagnosis of leptospirosis, using the Microscopic Agglutination Test: a validation study.

    Science.gov (United States)

    Dassanayake, Dinesh L B; Wimalaratna, Harith; Agampodi, Suneth B; Liyanapathirana, Veranja C; Piyarathna, Thibbotumunuwe A C L; Goonapienuwala, Bimba L

    2009-04-22

    Leptospirosis is endemic in both urban and rural areas of Sri Lanka and there had been many out breaks in the recent past. This study was aimed at validating the leptospirosis surveillance case definition, using the Microscopic Agglutination Test (MAT). The study population consisted of patients with undiagnosed acute febrile illness who were admitted to the medical wards of the Teaching Hospital Kandy, from 1st July 2007 to 31st July 2008. The subjects were screened to diagnose leptospirosis according to the leptospirosis case definition. MAT was performed on blood samples taken from each patient on the 7th day of fever. Leptospirosis case definition was evaluated in regard to sensitivity, specificity and predictive values, using a MAT titre >or= 1:800 for confirming leptospirosis. A total of 123 patients were initially recruited of which 73 had clinical features compatible with the surveillance case definition. Out of the 73 only 57 had a positive MAT result (true positives) leaving 16 as false positives. Out of the 50 who didn't have clinical features compatible with the case definition 45 had a negative MAT as well (true negatives), therefore 5 were false negatives. Total number of MAT positives was 62 out of 123. According to these results the test sensitivity was 91.94%, specificity 73.77%, positive predictive value and negative predictive values were 78.08% and 90% respectively. Diagnostic accuracy of the test was 82.93%. This study confirms that the surveillance case definition has a very high sensitivity and negative predictive value with an average specificity in diagnosing leptospirosis, based on a MAT titre of >or= 1: 800.

  15. Pacific region influenza surveillance for oseltamivir resistance.

    Science.gov (United States)

    Miller, Heather B; Gose, Remedios B; Nagata, Mark T; Sciulli, Rebecca H; Whelen, A Christian

    2012-05-01

    Hawaii and the United States-affiliated Pacific islands (USAPI) host over 8 million travelers annually, most of whom originate in Asia, Australia, and the Americas where prevalence of oseltamivir resistance in 2009 pandemic influenza A (H1N1) has been reported to be 2.5-3.5%. To survey a collection of samples from Hawaii and the USAPI that had tested positive for the 2009 pandemic influenza A (H1N1) virus by RTI-PCR to assess whether antiviral resistance emerged in these island communities during the 2009 H1N1 pandemic. We examined RNA extracted from Hawaiian and USAPI cases for the neuraminidase H275Y mutation associated with oseltamivir resistance by pyrosequencing. Two hundred and sixty-three (263) 2009 pandemic influenza A (H1N1) positive specimens were tested and 263/263 (100%) were shown to lack the mutation most commonly associated with oseltamivir resistance. There was no evidence of oseltamivir resistant A(H1N1)pdm09 virus during the 2009 pandemic in the Pacific islands despite considerable travel exposure. Geographic isolation, the lack of a "second wave" of pandemic influenza, judicious antiviral use, aggressive vaccination, and below average tourism due to the global economic crisis may have been contributing factors. Continued surveillance and vigilance is necessary to monitor unpredictable influenza activity. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. An Evaluation of the Cobas4800 HPV Test on Cervico-Vaginal Specimens in Liquid versus Solid Transport Media.

    Directory of Open Access Journals (Sweden)

    Hongxue Luo

    Full Text Available Determine the ability of the Cobas 4800 assay to detect high-risk human papillomavirus (HrHPV and high-grade cervical lesions when using cervico-vaginal samples applied to liquid medium and solid media cards compared to a direct cervical sample.Two cervico-vaginal specimens (pseudo self-collected were obtained from 319 women. One was applied to an iFTA Card (FTA then the brush placed in liquid-based medium (LSELF; the other was applied to a new solid media: POI card (POI. The clinical performance of Cobas4800 assay using the three aforementioned specimens was compared to direct collected endocervical specimens in liquid media (LDOC.The overall agreements of HrHPV detection were 84.2% (LSELF vs. LDOC, 81.0% (FTA vs. LDOC, and 82.3% (POI vs. LDOC. LSELF, FTA and POI identified 98.0%, 79.6%, and 97.5% positive cases of LDOC. Sensitivity to identify CIN2+ were 98.4% (LSELF, 73.8% (FTA, 95.1% (POI, and 93.4% (LDOC respectively. FTA had 78.1% and 90.4% agreement with the LSELF samples for all HrHPV and HPV16/18 detection respectively, while POI had 91.6% for both.Cobas4800 HPV test combined with cervico-vaginal specimens applied to both liquid media and POI solid card are accurate to detect HrHPV infection and high-grade cervical lesions as compared with direct endocervical samples in liquid media.

  17. An Evaluation of the Cobas4800 HPV Test on Cervico-Vaginal Specimens in Liquid versus Solid Transport Media.

    Science.gov (United States)

    Luo, Hongxue; Du, Hui; Maurer, Kathryn; Belinson, Jerome L; Wang, Guixiang; Liu, Zhihong; Zhang, Lijie; Zhou, Yanqiu; Wang, Chun; Tang, Jinlong; Qu, Xinfeng; Wu, Ruifang

    2016-01-01

    Determine the ability of the Cobas 4800 assay to detect high-risk human papillomavirus (HrHPV) and high-grade cervical lesions when using cervico-vaginal samples applied to liquid medium and solid media cards compared to a direct cervical sample. Two cervico-vaginal specimens (pseudo self-collected) were obtained from 319 women. One was applied to an iFTA Card (FTA) then the brush placed in liquid-based medium (LSELF); the other was applied to a new solid media: POI card (POI). The clinical performance of Cobas4800 assay using the three aforementioned specimens was compared to direct collected endocervical specimens in liquid media (LDOC). The overall agreements of HrHPV detection were 84.2% (LSELF vs. LDOC), 81.0% (FTA vs. LDOC), and 82.3% (POI vs. LDOC). LSELF, FTA and POI identified 98.0%, 79.6%, and 97.5% positive cases of LDOC. Sensitivity to identify CIN2+ were 98.4% (LSELF), 73.8% (FTA), 95.1% (POI), and 93.4% (LDOC) respectively. FTA had 78.1% and 90.4% agreement with the LSELF samples for all HrHPV and HPV16/18 detection respectively, while POI had 91.6% for both. Cobas4800 HPV test combined with cervico-vaginal specimens applied to both liquid media and POI solid card are accurate to detect HrHPV infection and high-grade cervical lesions as compared with direct endocervical samples in liquid media.

  18. Choosing the correct empirical antibiotic for urinary tract infection in pediatric: Surveillance of antimicrobial susceptibility pattern of Escherichia coli by E-Test method.

    Science.gov (United States)

    Sedighi, Iraj; Solgi, Abbas; Amanati, Ali; Alikhani, Mohammad Yousef

    2014-12-01

    Urinary Tract Infections (UTIs) are of the most common bacterial diseases worldwide. We investigate the antibiotic susceptibility patterns of Escherichia coli (E. coli) strains isolated from pediatric patients with community acquired urinary tract infection (UTI) to find a clinical guidance for choosing a right empirical antibiotic in these patients. In this cross sectional study, 100 urine specimens which were positive for E. coli had been investigated for antibiotics susceptibility pattern. The susceptibility to Co-trimoxazol (25μg), Amikacin (30μg), Ceftriaxone (30μg), Nalidixic Acid (30μg), Cefixime (5μg), and Nitrofurantoin (300μg) tested with Disk diffusion agar and MIC determined with the E-test. Mean age of patients was 38 Months. Girls had greater proportion than boys (74 versus 26%). In Disk diffusion method, 26% of the isolates were susceptible to cotrimoxazole. Susceptibility to amikacin, ceftriaxone, nitrofurantoin, nalidixic acid and cefixime was 94%, 66%, 97%, 62% and 52%, respectively. By E-Test method and according to CLSI criteria susceptibility for co-trimoxazol, amikacin, ceftriaxone and nalidixic acid was 37%, 97%, 67% and 50%, respectively. The highest percentage of agreement between Disk diffusion and E-Test method was found for amikacin (96%) and the lowest percentage for co-trimoxazole (89%). Treatment failure, prolonged or repeated hospitalization, increased costs of care, and increased mortality are some consequence of bacterial resistance in UTIs. Misuse of antibiotics in each geographic location directly affects antibiotic resistance pattern. In the treatment of UTI, proper selection of antimicrobial agents should be relevant to the bacterial susceptibility testing surveillance. According to our results, amikacin as an injectable drug and nitrofurantoin as an oral agent could be used as a drug of choice in our region for children with UTIs.

  19. Comparative study on Charpy specimen reconstitution techniques

    International Nuclear Information System (INIS)

    Bourdiliau, B.; Decroix, G.-M.; Averty, X.; Wident, P.; Bienvenu, Y.

    2011-01-01

    Highlights: → Welding processes are used to reconstitute previously tested Charpy specimens. → Stud welding is preferred for a quick installation, almost immediately operational. → Friction welding produces better quality welds, but requires a development effort. - Abstract: Reconstitution techniques are often used to allow material from previously fractured Charpy-V specimens to be reused for additional experiments. This paper presents a comparative experimental study of various reconstitution techniques and evaluates the feasibility of these methods for future use in shielded cells. The following techniques were investigated: arc stud welding, 6.0 kW CO 2 continuous wave laser welding, 4.5 kW YAG continuous wave laser welding and friction welding. Subsize Charpy specimens were reconstituted using a 400 W YAG pulsed wave laser. The best result was obtained with arc stud welding; the resilience of the reconstituted specimens and the load-displacement curves agreed well with the reference specimens, and the temperature elevation caused by the welding process was limited to the vicinity of the weld. Good results were also obtained with friction welding; this process led to the best quality welds. Laser welding seems to have affected the central part of the specimens, thus leading to different resilience values and load-displacement curves.

  20. Environmental surveillance and research at the Nevada Test Site: The beginning and the rationale

    International Nuclear Information System (INIS)

    Elle, D.R.; Church, B.W.; Bingham, F.E.

    1990-01-01

    Concurrently with the first nuclear-weapons tests at the Nevada Test Site (NTS) in 1951, an environmental surveillance and monitoring program was established offsite. Initial emphasis was on tracking fallout clouds and measuring external radiation exposure rates. An environmental research program was also initiated. Establishment of comprehensive programs has facilitated the ability to address issues such as the inventory and distribution of radionuclides in surface soils, reconstruction of offsite population doses, and recognition of areas requiring additional information. We have learned that a successful environmental monitoring program must be flexible and responsive to change; must address public as well as technical and regulatory concerns; and results must be continuously interpreted to ensure that all pathways are considered and the programs are proactive in their approach

  1. Twelve years of fireworks market surveillance in France

    OpenAIRE

    Branka , Ruddy

    2012-01-01

    International audience; In the view of market surveillance, more than 4400 fireworks have been taken on the spot by sworn people or bought on the market in France since 1999 for inspection purposes. This paper presents the market surveillance sampling evolution during twelve years, carried out by the PYRO unit of the Accidental Risks Division of INERIS as testing body ; the related measures implemented : additional audits in importer plants, interlaboratory tests for guarantying the reliabili...

  2. Introduction to surveillance studies

    CERN Document Server

    Petersen, JK

    2012-01-01

    Introduction & OverviewIntroduction Brief History of Surveillance Technologies & TechniquesOptical SurveillanceAerial Surveillance Audio Surveillance Radio-Wave SurveillanceGlobal Positioning Systems Sensors Computers & the Internet Data Cards Biochemical Surveillance Animal Surveillance Biometrics Genetics Practical ConsiderationsPrevalence of Surveillance Effectiveness of Surveillance Freedom & Privacy IssuesConstitutional Freedoms Privacy Safeguards & Intrusions ResourcesReferences Glossary Index

  3. Reviewing surveillance activities in nuclear power plants

    International Nuclear Information System (INIS)

    1989-03-01

    This document provides guidance to Operational Safety Review Teams (OSARTs) for reviewing surveillance activities at a nuclear power plant. In addition, the document contains reference material to support the review of surveillance activities, to assist within the Technical Support area and to ensure consistency between individual reviews. Drafts of the document have already been used on several OSART missions and found to be useful. The document first considers the objectives of an excellent surveillance programme. Investigations to determine the quality of the surveillance programme are then discussed. The attributes of an excellent surveillance programme are listed. Advice follows on how to phrase questions so as to obtain an informative response on surveillance features. Finally, specific equipment is mentioned that should be considered when reviewing functional tests. Four annexes provide examples drawn from operating nuclear power plants. They were selected to supplement the main text of the document with the best international practices as found in OSART reviews. They should in no way limit the acceptance and development of alternative approaches that lead to equivalent or better results. Refs, figs and tabs

  4. The response of pressure vessel steel specimens on drop weight loading

    International Nuclear Information System (INIS)

    Winkler, S.; Kalthoff, J.F.; Gerscha, A.

    1979-01-01

    Load records obtained in instrumented impact tests in general are disturbed by inertia effects. The influence of mechanical damping provisions on these disturbing inertia effects is investigated. Precracked bend specimens are dynamically loaded in a drop weight testing system. The specimens of size 620 mm x 150 mm (25 mm or 50 mm thick) were machined from the pressure vessel steel 22 NiMoCr 37 which was heat treated to achieve a specially hardened condition. The tests were performed at two different low temperatures. The impact velocity was about 4 m/s. As it is usual in instrumented impact testing, the load at the tup of the impining striker is recorded as a function of time during the impact process. In addition the specimen is instrumented by a strain gage close to the crack tip in order to directly measure the stress intensification. Experiments were performed under pure and damped impact conditions. Damping was achieved by utilizing a soft aluminum plate between the striker and the specimen. (orig.)

  5. Scanning transmission ion micro-tomography (STIM-T) of biological specimens

    International Nuclear Information System (INIS)

    Schwertner, Michael; Sakellariou, Arthur; Reinert, Tilo; Butz, Tilman

    2006-01-01

    Computed tomography (CT) was applied to sets of Scanning Transmission Ion Microscopy (STIM) projections recorded at the LIPSION ion beam laboratory (Leipzig) in order to visualize the 3D-mass distribution in several specimens. Examples for a test structure (copper grid) and for biological specimens (cartilage cells, cygospore) are shown. Scanning Transmission Micro-Tomography (STIM-T) at a resolution of 260 nm was demonstrated for the first time. Sub-micron features of the Cu-grid specimen were verified by scanning electron microscopy. The ion energy loss measured during a STIM-T experiment is related to the mass density of the specimen. Typically, biological specimens can be analysed without staining. Only shock freezing and freeze-drying is required to preserve the ultra-structure of the specimen. The radiation damage to the specimen during the experiment can be neglected. This is an advantage compared to other techniques like X-ray micro-tomography. At present, the spatial resolution is limited by beam position fluctuations and specimen vibrations

  6. FY2005 AND FY2006 CORROSION SURVEILLANCE RESULTS FOR L BASIN

    International Nuclear Information System (INIS)

    Vormelker, P.; Cynthia Foreman, C.

    2008-01-01

    This report documents the results of the L-Basin Corrosion Surveillance Program for the fiscal years 2005 and 2006. The water quality and basin conditions for the coupon immersion period are compared to the corrosion evaluation results from detailed metallurgical analysis of the coupons. Test coupons were removed from the basin on two occasions, March 29, 2005 and May 23, 2006, examined and photographed. Selected coupons were metallurgically characterized to evaluate the extent of general corrosion and pitting. Crystallographic and energy dispersive spectroscopy analysis were performed on a typical specimen, as-removed from the basin, to characterize the surface debris. Marked changes were noted in both the 2005 and 2006 specimens compared to previous years corrosion results. A new pitting incidence has occurred on the faces of the aluminum coupons compared to localized pitting at crevice regions only on specimens withdrawn in 2003 and 2004. The pitting incidence is attributed to sand filter fines that entered the basin on July 27, 2004 from an inadvertent backflush of the new sand filter. Pitting rate results show a trend of slowing down over time which is consistent with aluminum pit kinetics. Average pit growth rates were equal to or lower in all 2006 aluminum coupons than those removed in 2005. A trend line shows that pitting corrosion rates on Al1100, 6061, and 6063 coupons are slowing down since pit depth measurements were initiated in 2003. No impact to stored spent fuel is expected from the debris. The storage configuration of the majority of L-Basin spent fuel, in bundles, should provide a measure of isolation from debris settling in the basin

  7. Small punch tensile/fracture test data and 3D specimen surface data on Grade 91 ferritic/martensitic steel from cryogenic to room temperature.

    Science.gov (United States)

    Bruchhausen, Matthias; Lapetite, Jean-Marc; Ripplinger, Stefan; Austin, Tim

    2016-12-01

    Raw data from small punch tensile/fracture tests at two displacement rates in the temperature range from -196 °C to room temperature on Grade 91 ferritic/martensitic steel are presented. A number of specimens were analyzed after testing by means of X-ray computed tomography (CT). Based on the CT volume data detailed 3D surface maps of the specimens were established. All data are open access and available from Online Data Information Network (ODIN)https://odin.jrc.ec.europa.eu. The data presented in the current work has been analyzed in the research article "On the determination of the ductile to brittle transition temperature from small punch tests on Grade 91 ferritic-martensitic steel" (M. Bruchhausen, S. Holmström, J.-M. Lapetite, S. Ripplinger, 2015) [1].

  8. A study on assessment methodology of surveillance test interval and allowed outage time

    International Nuclear Information System (INIS)

    Che, Moo Seong; Cheong, Chang Hyeon; Lee, Byeong Cheol

    1996-07-01

    The objectives of this study is the development of methodology by which assessing the optimizes Surveillance Test Interval(STI) and Allowed Outage Time(AOT) using PSA method that can supplement the current deterministic methods and the improvement of Korea nuclear power plants safety. In the first year of this study, the survey about the assessment methodologies, modeling and results performed by domestic and international researches is performed as the basic step before developing the assessment methodology of this study. The assessment methodology that supplement the revealed problems in many other studies is presented and the application of new methodology into the example system assures the feasibility of this method

  9. A study on assessment methodology of surveillance test interval and allowed outage time

    Energy Technology Data Exchange (ETDEWEB)

    Che, Moo Seong; Cheong, Chang Hyeon; Lee, Byeong Cheol [Seoul Nationl Univ., Seoul (Korea, Republic of)] (and others)

    1996-07-15

    The objectives of this study is the development of methodology by which assessing the optimizes Surveillance Test Interval(STI) and Allowed Outage Time(AOT) using PSA method that can supplement the current deterministic methods and the improvement of Korea nuclear power plants safety. In the first year of this study, the survey about the assessment methodologies, modeling and results performed by domestic and international researches is performed as the basic step before developing the assessment methodology of this study. The assessment methodology that supplement the revealed problems in many other studies is presented and the application of new methodology into the example system assures the feasibility of this method.

  10. Surveillance robot for nuclear power plants

    International Nuclear Information System (INIS)

    White, J.R.; Harvey, H.W.; Satterlee, P.E. Jr.

    1985-01-01

    A demonstration project to determine the feasibility and cost-effectiveness of mobile surveillance robots in nuclear power plants is being conducted by the Remote Technology Corporation (REMOTEC) for the US Nuclear Regulatory Commission. Phase I of the project was completed in March 1984 and included a survey of currently used robotic equipment and the development of a robotics application methodology. Three Tennessee Valley Authority plants were analyzed to identify specific plant areas with a high potential for surveillance robotics. Based on these results, a number of robotic system applications were prepared and evaluated for cost-effectiveness. The system with the highest potential, a mobile surveillance robot, was selected for fabrication and in-plant demonstration testing in a phase II effort. The design, fabrication, and assembly of SURBOT has been completed and cold testing is in process. It will be installed at the Browns Ferry Nuclear Plant early in 1986 for demonstration testing. Current projections are that SURBOT can be used in approx.40 rooms within the auxiliary building and will have annual savings of over 100 person-rem exposure, 1000 sets of C-zone clothing, and 1000 person-hours of labor

  11. Technology development on production of test specimens from irradiated capsule outer-tube and mechanical evaluation test of stainless steel with high dose carried out by the technology

    International Nuclear Information System (INIS)

    Hayashi, Koji; Shibata, Akira; Iwamatsu, Shigemi; Sozawa, Shizuo; Takada, Fumiki; Ohmi, Masao; Nakagawa, Tetsuya

    2008-03-01

    The irradiation capsule 74M-52J was irradiated during total 136 cycles at reactor core of JMTR and the maximum neutron dose reached on 3.9x10 26 n/m 2 at the capsule outer-tube made of a type 304 stainless steel. In order to produce mechanical test specimens from the outer-tube, a punching technique was developed as a simple remote-handling method in a hot-cell. From comparison between the punching and the mechanical cutting methods, it was clarified that the punching technique was applicable to practical use. Moreover, an evaluation test of mechanical properties using specimens sampled from the 74M-52 was performed with in-water high temperature condition, less than 288degC. The result shows that the residual elongation is 18% at 150degC and 13% at 288degC. It was confirmed that the type 304 stainless steel irradiated up to such high dose shows enough ductility. (author)

  12. Study of residual stresses in CT test specimens welded by electron beam

    Science.gov (United States)

    Papushkin, I. V.; Kaisheva, D.; Bokuchava, G. D.; Angelov, V.; Petrov, P.

    2018-03-01

    The paper reports result of residual stress distribution studies in CT specimens reconstituted by electron beam welding (EBW). The main aim of the study is evaluation of the applicability of the welding technique for CT specimens’ reconstitution. Thus, the temperature distribution during electron beam welding of a CT specimen was calculated using Green’s functions and the residual stress distribution was determined experimentally using neutron diffraction. Time-of-flight neutron diffraction experiments were performed on a Fourier stress diffractometer at the IBR-2 fast pulsed reactor in FLNP JINR (Dubna, Russia). The neutron diffraction data estimates yielded a maximal stress level of ±180 MPa in the welded joint.

  13. Thermal expansion of epoxy-fiberglass composite specimens

    International Nuclear Information System (INIS)

    McElroy, D.L.; Weaver, F.J.; Bridgman, C.

    1986-01-01

    The thermal expansion behavior of three epoxy-fiberglass composite specimens was measured from 20 to 120 0 C (70 to 250 0 F) using a fused quartz push-rod dilatometer. Billets produced by vacuum impregnating layers of two types of fiberglass cloth with an epoxy resin were core-drilled to produce cylindrical specimens. These were used to study expansion perpendicular and parallel to the fiberglass layers. The dilatometer is held at a preselected temperature until steady-state is indicated by stable length and temperature data. Before testing the composite specimens, a reliability check of the dilatometer was performed using a copper secondary standard. This indicated thermal expansion coefficient (α) values within +-2% of expected values from 20 to 200 0 C

  14. Nationwide surveillance of the antimicrobial susceptibility of Neisseria gonorrhoeae from male urethritis in Japan.

    Science.gov (United States)

    Hamasuna, Ryoichi; Yasuda, Mitsuru; Ishikawa, Kiyohito; Uehara, Shinya; Takahashi, Satoshi; Hayami, Hiroshi; Yamamoto, Shingo; Matsumoto, Tetsuro; Minamitani, Shinichi; Watanabe, Akira; Iwamoto, Aikichi; Totsuka, Kyoichi; Kadota, Junichi; Sunakawa, Keisuke; Sato, Junko; Hanaki, Hideaki; Tsukamoto, Taiji; Kiyota, Hiroshi; Egawa, Shin; Tanaka, Kazushi; Arakawa, Soichi; Fujisawa, Masato; Kumon, Hiromi; Kobayashi, Kanao; Matsubara, Akio; Naito, Seiji; Tatsugami, Katsunori; Ito, Shin; Narita, Harunori; Kanokogi, Mototsugu; Sumii, Toru; Ito, Kenji; Hosobe, Takahide; Kawai, Shuichi; Kawano, Hiromi; Takayama, Kazuo; Yamaguchi, Takamasa; Endo, Katsuhisa; Yamauchi, Takamine; Maeda, Shinichi; Yoh, Mutsumasa; Horie, Masanobu; Ito, Masayasu; Chokyu, Hirofumi; Ihara, Hideari; Akiyama, Kikuo; Uno, Satoshi; Monden, Koichi; Kaji, Shinichi; Nishimura, Hirofumi; Kawahara, Motoshi; Sato, Takashi; Konishi, Takatoshi; Nishi, Shohei; Ishihara, Satoshi; Yoshioka, Masaru

    2013-08-01

    Neisseria gonorrhoeae is one of the most important pathogens causing sexually transmitted infection, and strains that are resistant to several antimicrobials are increasing. To investigate the trends of antimicrobial susceptibility among N. gonorrhoeae strains isolated from male patients with urethritis, a Japanese surveillance committee conducted the first nationwide surveillance. The urethral discharge was collected from male patients with urethritis at 51 medical facilities from April 2009 to October 2010. Of the 156 specimens, 83 N. gonorrhoeae strains were tested for susceptibility to 18 antimicrobial agents. The prevalence of β-lactamase-producing strains and chromosomally mediated resistant strains were 7.2 % and 16.5 %, respectively. None of the strains was resistant to ceftriaxone, but the minimum inhibitory concentration (MIC) of ceftriaxone for 7 strains (8.4 %) was 0.125 μg/ml. One strain was resistant to cefixime (MIC 0.5 μg/ml). The MICs of fluoroquinolones, such as ciprofloxacin, levofloxacin, and tosufloxacin, showed a bimodal distribution. The MIC of sitafloxacin was lower than those of the three fluoroquinolones listed here, and it was found that the antimicrobial activity of sitafloxacin was stronger than that of the fluoroquinolones. The MIC of azithromycin in 2 strains was 2 μg/ml, but no high-level resistance to macrolides was detected.

  15. Use of precracked Charpy and smaller specimens to establish the master curve

    International Nuclear Information System (INIS)

    Sokolov, M.A.; McCabe, D.E.; Nanstad, R.K.; Davidov, Y.A.

    1997-01-01

    The current provisions used in the U.S. Code of Federal Regulations for the determination of the fracture toughness of reactor pressure vessel steels employs an assumption that there is a direct correlation between K Ic lower-bound toughness and the Charpy V-notch transition curve. Such correlations are subject to scatter from both approaches which weakens the reliability of fracture mechanics-based analyses. In this study, precracked Charpy and smaller size specimens are used in three-point static bend testing to develop fracture mechanics based K k values. The testing is performed under carefully controlled conditions such that the values can be used to predict the fracture toughness performance of large specimens. The concept of a universal transition curve (master curve) is applied. Data scatter that is characteristic of commercial grade steels and their weldments is handled by Weibull statistical modeling. The master curve is developed to describe the median K Jc fracture toughness for 1T size compact specimens. Size effects are modeled using weakest-link theory and are studied for different specimen geometries. It is shown that precracked Charpy specimens when tested within their confined validity limits follow the weakest-link size-adjustment trend and predict the fracture toughness of larger specimens. Specimens of smaller than Charpy sizes (5 mm thick) exhibit some disparities in results relative to weakest-link size adjustment prediction suggesting that application of such adjustment to very small specimens may have some limitations

  16. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal

    Science.gov (United States)

    Dieye, Yakou; Barrett, Kelsey L.; Gerth-Guyette, Emily; Di Giorgio, Laura; Golden, Allison; Faulx, Dunia; Kalnoky, Michael; Ndiaye, Marie Khemesse Ngom; Sy, Ngayo; Mané, Malang; Faye, Babacar; Sarr, Mamadou; Dioukhane, Elhadji Mamadou; Peck, Roger B.; Guinot, Philippe; de los Santos, Tala

    2017-01-01

    As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16) rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7%) agreed to the rapid test while 383 (32.7%) agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools. PMID:28972982

  17. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal.

    Directory of Open Access Journals (Sweden)

    Yakou Dieye

    2017-10-01

    Full Text Available As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16 rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7% agreed to the rapid test while 383 (32.7% agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools.

  18. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal.

    Science.gov (United States)

    Dieye, Yakou; Storey, Helen L; Barrett, Kelsey L; Gerth-Guyette, Emily; Di Giorgio, Laura; Golden, Allison; Faulx, Dunia; Kalnoky, Michael; Ndiaye, Marie Khemesse Ngom; Sy, Ngayo; Mané, Malang; Faye, Babacar; Sarr, Mamadou; Dioukhane, Elhadji Mamadou; Peck, Roger B; Guinot, Philippe; de Los Santos, Tala

    2017-10-01

    As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16) rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7%) agreed to the rapid test while 383 (32.7%) agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools.

  19. The epidemiology and surveillance response to pandemic influenza A (H1N1) among local health departments in the San Francisco Bay Area.

    Science.gov (United States)

    Enanoria, Wayne T A; Crawley, Adam W; Tseng, Winston; Furnish, Jasmine; Balido, Jeannie; Aragón, Tomás J

    2013-03-27

    (including hospitalized and fatal cases) and laboratory testing data were used by all organizations. While almost every LHD attempted to collect school absenteeism data, many respondents reported problems in collecting and analyzing these data. Laboratory capacity to test influenza specimens often aided an LHD's ability to conduct disease investigations and implement control measures, but the ability to test specimens varied across the region and even well-equipped laboratories exceeded their capacity. As a whole, the health jurisdictions in the region communicated regularly about key decision-making (continued on next page) (continued from previous page) related to the response, and prior regional collaboration on pandemic influenza planning helped to prepare the region for the novel H1N1 influenza pandemic. The study did find, however, that many respondents (including the majority of epidemiologists interviewed) desired an increase in regional communication about epidemiology and surveillance issues. The study collected information about the epidemiology and surveillance response among LHDs in the San Francisco Bay Area that has implications for public health preparedness and emergency response training, public health best practices, regional public health collaboration, and a perceived need for information sharing.

  20. Specimen rejection in laboratory medicine: Necessary for patient safety?

    Science.gov (United States)

    Dikmen, Zeliha Gunnur; Pinar, Asli; Akbiyik, Filiz

    2015-01-01

    The emergency laboratory in Hacettepe University Hospitals receives specimens from emergency departments (EDs), inpatient services and intensive care units (ICUs). The samples are accepted according to the rejection criteria of the laboratory. In this study, we aimed to evaluate the sample rejection ratios according to the types of pre-preanalytical errors and collection areas. The samples sent to the emergency laboratory were recorded during 12 months between January to December, 2013 in which 453,171 samples were received and 27,067 specimens were rejected. Rejection ratios was 2.5% for biochemistry tests, 3.2% for complete blood count (CBC), 9.8% for blood gases, 9.2% for urine analysis, 13.3% for coagulation tests, 12.8% for therapeutic drug monitoring, 3.5% for cardiac markers and 12% for hormone tests. The most frequent rejection reasons were fibrin clots (28%) and inadequate volume (9%) for biochemical tests. Clotted samples (35%) and inadequate volume (13%) were the major causes for coagulation tests, blood gas analyses and CBC. The ratio of rejected specimens was higher in the EDs (40%) compared to ICUs (30%) and inpatient services (28%). The highest rejection ratio was observed in neurology ICU (14%) among the ICUs and internal medicine inpatient service (10%) within inpatient clinics. We detected an overall specimen rejection rate of 6% in emergency laboratory. By documentation of rejected samples and periodic training of healthcare personnel, we expect to decrease sample rejection ratios below 2%, improve total quality management of the emergency laboratory and promote patient safety.

  1. Experimental procedure for the characterization of cyclic behavior from very thin plate specimens

    International Nuclear Information System (INIS)

    Maury, A.; Moulin, D.

    1983-01-01

    Many investigators, including those involved in the INTERNATIONAL BENCHMARK PROJECT ON SIMPLIFIED METHODS FOR ELEVATED TEMPERATURE DESIGN AND ANALYSIS - PROBLEM II, have tried to reproduce experimentally observed behavior by inelastic calculations. Unfortunately, the material characteristics used in the computer code were established from monotonic tensile tests performed with specimens extracted from the plate product itself (1.45 mm thick) employed to construct the ratchetting specimen. It now appears that the cyclic behavior of the material is much more relevant to the phenomenon observed. Hence the need to make this kind of characterization. Nevertheless, the practical problem is to produce cyclic stresses, i.e. tensile and compressive stresses, with very thin specimens. The main difficulty is to prevent the buckling effect. A new special device set up for this particular purpose is described here. The solution adopted was to create uniformly distributed alternative pure bending stresses in the thin plate specimen. Bending moments were produced by two end-grips fixed to the specimen, and these grips were mounted on a conventional test-machine which was displacement-controlled. To reduce tensile and compressive membrane stresses inside the specimen, the grips had two parallel axles of rotation. The forces produced by the machine and the displacements of a number of points of the specimen were continuously recorded during the test, so that cyclically stabilized, bending moments could be evaluated easily for each curvature variation imposed. The very first cyclic experimental data obtained, at room temperature, for the material of the sodium test specimen, a 316 type stainless steel, are presented. It may be noted that the simple specimens were very easy to prepare and hence inexpensive. (orig.)

  2. Load bearing and deformation behaviour of dynamically loaded wide plate specimens

    International Nuclear Information System (INIS)

    Julisch, P.; Haedrich, H.J.; Stadtmueller, W.; Sturm, D.

    1989-01-01

    For the testing of large-scale specimens, a 12 MN-High Loading Rate Tensile Testing Machine was designed and built at MPA Stuttgart. The aim was to determine the influence of high loading rates on the stress and strain behaviour of unwelded and welded components of ferritic and austenitic materials. This new generation of testing machines is driven by a propellant charge, and generates a maximum tensile force of 12 MN with a piston velocity of 25 m/s after a stroke of 20 mm, or a maximum velocity of 60 m/s after a stroke of 400 mm. In a first test programme, welded and unwelded wide plate specimens made of material X 6 CrNi 18 11 were tested at room temperature with different strain rates from 10 -3 /s to 63/s. In addition to a description of the 12 MN-High Loading Rate Tensile Testing Machine, the results of the high loading rate tensile tests performed will be presented and compared with quasistatically tested wide plate specimens. (orig.)

  3. Hot cell examination on the surveillance capsule of SA 533 cl. 1 reactor pressure vessel (1st test report)

    Energy Technology Data Exchange (ETDEWEB)

    Choo, Yong Sun; Jung, Y. H.; Yoo, B. O.; Baik, S. J.; Oh, W. H.; Soong, W. S.; Hong, K. P

    2000-08-01

    The post-irradiated examinations such as impact test, tensile test, composition analysis and etc. were conducted to monitor and to evaluate the radiation-induced changes, so called radiation embrittlement, in the mechanical properties of ferritic materials. Those data should be applied to confirm safety as well as reliability of reactor pressure vessel. The scopes and contents of hot cell examination on the surveillance capsule are as follows; - Capsule transportation, cutting, dismantling and classification - Shim block and Dosimeter cutting and dismantling - Impact test - Tensile test - Composition analysis by EPMA - SEM observation on the fractured surface - Hardness test - Radwaste treatment.

  4. Visualization test using piping group mock up specimen for evaluation of wastage phenomena in steam generator for FBR

    International Nuclear Information System (INIS)

    Kato, Keisuke; Yoshida, Atsuro; Arae, Kunihiko; Narabayashi, Tadashi; Ohshima, Hiroyuki; Kurihara, Akikazu

    2012-01-01

    There is a need for quantitative evaluation of wastage phenomena in steam generator for FBR. We focused attention on liquid droplet impingement erosion (LDIE) in wastage phenomena and performed basic study with piping group mock up specimen for quantitative evaluation of LDIE. First, we did visualization test of high pressure and high speed jet into the water. Test section mock up the crack of heat exchanger tube and neighboring heat exchanger tubes. We did the test under the following test conditions. Upstream pressure is 0.3MPa, vapor temperature is 300K, crack width is 0.1mm, and crack length is 40mm. (crack diameter is 0.2mm) Second, we did pressure and temperature measurement test in the same test conditions as before. We evaluated jet behavior at test section by those two tests. In addition, we did two phase flow analysis of the jet with TRAC code. (author)

  5. Development of stress relaxation measurement by a small size C-ring specimen method

    International Nuclear Information System (INIS)

    Shimanuki, Shizuka; Nakata, Kiyotomo; Kasahara, Shigeki; Kuniya, Jiro

    2002-01-01

    A stress relaxation measurement method has been developed by using C-ring specimens, and a specimen size effect has been evaluated taking radiation-induced stress relaxation into consideration. C-ring specimens were stressed by forcing a wedge in the gap. Giving an appropriate eccentric configuration in the half of the ring opposite the gap, the stress gradient along the circumference was eliminated in the section and the stress level could be varied by changing the gap spacing. The validity of the C-ring test method was confirmed by thermally stress relaxation experiments at annealing temperatures from 300 to 600degC for 1 min to 200 h in carbon steel: considerable stress relaxation could be measured for all levels of applied stress even at relatively low annealing temperatures. The relaxation results obtained from the C-ring test were in good agreement with those from a uniaxial tensile stress relaxation test. The smaller C-ring specimen with about 40 mm diameter, which is required for radiation-induced stress relaxation test, also showed adequate accuracy on stress relaxation at 600 to 830degC in stainless steel, compared with the large size C-ring specimen test. (author)

  6. Culturing Stool Specimens for Campylobacter spp., Pennsylvania, USA

    Science.gov (United States)

    M’ikanatha, Nkuchia M.; Dettinger, Lisa A.; Perry, Amanda; Rogers, Paul; Reynolds, Stanley M.

    2012-01-01

    In 2010, we surveyed 176 clinical laboratories in Pennsylvania regarding stool specimen testing practices for enteropathogens, including Campylobacter spp. Most (96.3%) routinely test for Campylobacter spp. In 17 (15.7%), a stool antigen test is the sole method for diagnosis. We recommend that laboratory practice guidelines for Campylobacter spp. testing be developed. PMID:22377086

  7. The social dynamics of consent and refusal in HIV surveillance in rural South Africa.

    Science.gov (United States)

    Reynolds, Lindsey; Cousins, Thomas; Newell, Marie-Louise; Imrie, John

    2013-01-01

    In the context of low rates of participation in a prospective, population-based HIV surveillance programme, researchers at a surveillance site in rural KwaZulu-Natal, South Africa, conducted an operational study from January 2009 to February 2010, with the aim of improving participation rates, particularly in the provision of dried blood spots for the surveillance. Findings suggest, firstly, that consent to participation in the HIV surveillance is informed by the dynamics of relationality in the HIV surveillance "consent encounter." Secondly, it emerged that both fieldworkers and participants found it difficult to differentiate between HIV surveillance and HIV testing in the surveillance procedure, and tended to understand and explain giving blood under the aegis of the surveillance as an HIV test. The conflation of surveillance and testing, we argue, is not merely a semantic confusion, but reveals an important tension inherent to global health research between individual risks and benefits and collective good, or between private morality and public good. Because of these structural tensions, we suggest, the HIV surveillance consent encounter activates multiple gift economies in the collection of blood samples. Thinking beyond the complex ethical dimensions provoked by new forms of long-term surveillance and health research, we therefore suggest that deepening relations between scientists, fieldworkers, and study participants in locality deserve more careful methodological consideration and descriptive attention. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Estimations of creep behavior and failure life for a circumferentially notched specimen

    International Nuclear Information System (INIS)

    Kobayashi, Ken-ichi; Yokobori, Toshimitsu; Kikuchi, Kenji.

    1997-01-01

    No method with which to characterize and/or illustrate total creep behavior for specimens with notches, holes or cracks has been proposed. In this paper it is proposed that most creep curves can be drawn with a master curve for each creep test whenever test conditions and failure modes are similar to each other, and the lifetime ratio normalized by the rupture time is introduced. Using smooth and circumferentially notched specimens of 2.25 Cr-1 Mo steel, creep tests were performed at 600degC for examination of this concept. Furthermore, a θ projection method was used to describe creep curves for notched specimens and to extrapolate longer creep lives. Then, the whole creep curve shape for notched specimens could be easily drawn, except for that in the vicinity of the rupture point. However, longer creep lives of notched specimens were underestimated in comparison with a simple extrapolation of the experimental data. This resulted from the negative dependence of the parameter of θ 3 on the applied stress. (author)

  9. Full thickness crack arrest investigations on compact specimens and a heavy wide-plate

    International Nuclear Information System (INIS)

    Kussmaul, K.; Gillot, R.; Elenz, T.

    1993-01-01

    In order to determine the influence of specimen size and testing procedure on the crack arrest toughness K Ia at various temperatures, investigations were carried out on a wide-plate and compact specimens using a highly brittle material. Test interpretation included static as well as dynamic methods. The comparison of the measured K Ia -values shows good agreement although there is a distinct difference in specimen size. In general, the (static) ASTM test method yields a lower and thus conservative estimate of the crack arrest toughness K Ia . 14 refs., 27 figs., 3 tabs

  10. Clinical evaluation of a mobile digital specimen radiography system for intraoperative specimen verification.

    Science.gov (United States)

    Wang, Yingbing; Ebuoma, Lilian; Saksena, Mansi; Liu, Bob; Specht, Michelle; Rafferty, Elizabeth

    2014-08-01

    Use of mobile digital specimen radiography systems expedites intraoperative verification of excised breast specimens. The purpose of this study was to evaluate the performance of a such a system for verifying targets. A retrospective review included 100 consecutive pairs of breast specimen radiographs. Specimens were imaged in the operating room with a mobile digital specimen radiography system and then with a conventional digital mammography system in the radiology department. Two expert reviewers independently scored each image for image quality on a 3-point scale and confidence in target visualization on a 5-point scale. A target was considered confidently verified only if both reviewers declared the target to be confidently detected. The 100 specimens contained a total of 174 targets, including 85 clips (49%), 53 calcifications (30%), 35 masses (20%), and one architectural distortion (1%). Although a significantly higher percentage of mobile digital specimen radiographs were considered poor quality by at least one reviewer (25%) compared with conventional digital mammograms (1%), 169 targets (97%), were confidently verified with mobile specimen radiography; 172 targets (98%) were verified with conventional digital mammography. Three faint masses were not confidently verified with mobile specimen radiography, and conventional digital mammography was needed for confirmation. One faint mass and one architectural distortion were not confidently verified with either method. Mobile digital specimen radiography allows high diagnostic confidence for verification of target excision in breast specimens across target types, despite lower image quality. Substituting this modality for conventional digital mammography can eliminate delays associated with specimen transport, potentially decreasing surgical duration and increasing operating room throughput.

  11. Creep-fatigue assessment of a thermina test specimen using the R5 procedure

    International Nuclear Information System (INIS)

    Booth, P.; Budden, P.J.; Bate, S.K.

    1997-01-01

    A creep-fatigue life assessment of an axisymmetric 316 stainless steel test specimen under constant mechanical and cyclic thermal shock loading using the R5 Procedure is described in this paper. This test was carried out at CEA, France, and formed part of the 'Thermina' series. Stress analysis has been carried out using both full inelastic finite element analysis and also the simplified shakedown methods, based on elastic calculation, within R5. The estimates of strain range and the stress at the start of the creep dwell have then been used with R5 to estimate creep and fatigue damage per cycle and hence to make predictions of component life. The predicted lives are compared with the lives observed in the tests. The simplified R5 estimate of life, based on development of a crack of depth 200 microns, is 260 cycles using best-estimate material properties. Experimentally, cracks of depth at least 150 microns were observed in between 526 and 650 cycles, for two similar tests. The simplified R5 route therefore leads to an estimate of life which is conservative but not unduly so on this component. Detailed cyclic inelastic analysis using the ORNL constitutive model and the ABAQUS finite element code to estimate the strain range and dwell stress led to a best estimate of 618 cycles to crack initiation using R5. (author). 16 refs, 11 figs, 4 tabs

  12. Final report : mobile surveillance and wireless communication systems field operational test. Volume 2, FOT objectives, organization, system design, results, conclusions, and recommendations

    Science.gov (United States)

    1999-03-01

    The Mobile Surveillance and Wireless Communication Systems Field Operational Test (FOT) evaluated the performance of wireless traffic detection and communications systems in areas where permanent detectors, electrical power, and landline communicatio...

  13. Reliability of case definitions for public health surveillance assessed by Round-Robin test methodology

    Directory of Open Access Journals (Sweden)

    Claus Hermann

    2006-05-01

    Full Text Available Abstract Background Case definitions have been recognized to be important elements of public health surveillance systems. They are to assure comparability and consistency of surveillance data and have crucial impact on the sensitivity and the positive predictive value of a surveillance system. The reliability of case definitions has rarely been investigated systematically. Methods We conducted a Round-Robin test by asking all 425 local health departments (LHD and the 16 state health departments (SHD in Germany to classify a selection of 68 case examples using case definitions. By multivariate analysis we investigated factors linked to classification agreement with a gold standard, which was defined by an expert panel. Results A total of 7870 classifications were done by 396 LHD (93% and all SHD. Reporting sensitivity was 90.0%, positive predictive value 76.6%. Polio case examples had the lowest reporting precision, salmonellosis case examples the highest (OR = 0.008; CI: 0.005–0.013. Case definitions with a check-list format of clinical criteria resulted in higher reporting precision than case definitions with a narrative description (OR = 3.08; CI: 2.47–3.83. Reporting precision was higher among SHD compared to LHD (OR = 1.52; CI: 1.14–2.02. Conclusion Our findings led to a systematic revision of the German case definitions and build the basis for general recommendations for the creation of case definitions. These include, among others, that testable yes/no criteria in a check-list format is likely to improve reliability, and that software used for data transmission should be designed in strict accordance with the case definitions. The findings of this study are largely applicable to case definitions in many other countries or international networks as they share the same structural and editorial characteristics of the case definitions evaluated in this study before their revision.

  14. Attaching Hollywood to a Surveillant Assemblage: Normalizing Discourses of Video Surveillance

    Directory of Open Access Journals (Sweden)

    Randy K Lippert

    2015-10-01

    Full Text Available This article examines video surveillance images in Hollywood film. It moves beyond previous accounts of video surveillance in relation to film by theoretically situating the use of these surveillance images in a broader “surveillant assemblage”. To this end, scenes from a sample of thirty-five (35 films of several genres are examined to discern dominant discourses and how they lend themselves to normalization of video surveillance. Four discourses are discovered and elaborated by providing examples from Hollywood films. While the films provide video surveillance with a positive associative association it is not without nuance and limitations. Thus, it is found that some forms of resistance to video surveillance are shown while its deterrent effect is not. It is ultimately argued that Hollywood film is becoming attached to a video surveillant assemblage discursively through these normalizing discourses as well as structurally to the extent actual video surveillance technology to produce the images is used.

  15. Converting Mosquito Surveillance to Arbovirus Surveillance with Honey-Baited Nucleic Acid Preservation Cards.

    Science.gov (United States)

    Flies, Emily J; Toi, Cheryl; Weinstein, Philip; Doggett, Stephen L; Williams, Craig R

    2015-07-01

    Spatially and temporally accurate information about infectious mosquito distribution allows for pre-emptive public health interventions that can reduce the burden of mosquito-borne infections on human populations. However, the labile nature of arboviruses, the low prevalence of infection in mosquitoes, the expensive labor costs for mosquito identification and sorting, and the specialized equipment required for arbovirus testing can obstruct arbovirus surveillance efforts. The recently developed techniques of testing mosquito expectorate using honey-baited nucleic acid preservation cards or sugar bait stations allows a sensitive method of testing for infectious, rather than infected, mosquito vectors. Here we report the results from the first large-scale incorporation of honey-baited cards into an existing mosquito surveillance program. During 4 months of the peak virus season (January-April, 2014) for a total of 577 trap nights, we set CO2-baited encephalitis vector survey (EVS) light traps at 88 locations in South Australia. The collection container for the EVS trap was modified to allow for the placement of a honey-baited nucleic acid preservation card (FTA™ card) inside. After collection, mosquitoes were maintained in a humid environment and allowed access to the cards for 1 week. Cards were then analyzed for common endemic Australian arboviruses using a nested RT-PCR. Eighteen virus detections, including 11 Ross River virus, four Barmah Forest virus, and three Stratford virus (not previously reported from South Australia) were obtained. Our findings suggest that adding FTA cards to an existing mosquito surveillance program is a rapid and efficient way of detecting infectious mosquitoes with high spatial resolution.

  16. Infection with Pathogens Transmitted Commonly Through Food and the Effect of Increasing Use of Culture-Independent Diagnostic Tests on Surveillance--Foodborne Diseases Active Surveillance Network, 10 U.S. Sites, 2012-2015.

    Science.gov (United States)

    Huang, Jennifer Y; Henao, Olga L; Griffin, Patricia M; Vugia, Duc J; Cronquist, Alicia B; Hurd, Sharon; Tobin-D'Angelo, Melissa; Ryan, Patricia; Smith, Kirk; Lathrop, Sarah; Zansky, Shelley; Cieslak, Paul R; Dunn, John; Holt, Kristin G; Wolpert, Beverly J; Patrick, Mary E

    2016-04-15

    To evaluate progress toward prevention of enteric and foodborne illnesses in the United States, the Foodborne Diseases Active Surveillance Network (FoodNet) monitors the incidence of laboratory-confirmed infections caused by nine pathogens transmitted commonly through food in 10 U.S. sites. This report summarizes preliminary 2015 data and describes trends since 2012. In 2015, FoodNet reported 20,107 confirmed cases (defined as culture-confirmed bacterial infections and laboratory-confirmed parasitic infections), 4,531 hospitalizations, and 77 deaths. FoodNet also received reports of 3,112 positive culture-independent diagnostic tests (CIDTs) without culture-confirmation, a number that has markedly increased since 2012. Diagnostic testing practices for enteric pathogens are rapidly moving away from culture-based methods. The continued shift from culture-based methods to CIDTs that do not produce the isolates needed to distinguish between strains and subtypes affects the interpretation of public health surveillance data and ability to monitor progress toward prevention efforts. Expanded case definitions and strategies for obtaining bacterial isolates are crucial during this transition period.

  17. Surveillance of working conditions and the work environment: development of a national hazard surveillance tool in New Zealand.

    Science.gov (United States)

    Lilley, Rebbecca; Feyer, Anne-Marie; Firth, Hilda; Cunningham, Chris; Paul, Charlotte

    2010-02-01

    Changes to work and the impact of these changes on worker health and safety have been significant. A core surveillance data set is needed to understand the impact of working conditions and work environments. Yet, there is little harmony amongst international surveys and a critical lack of guidance identifying the best directions for surveillance efforts. This paper describes the establishment of an instrument suitable for use as a hazard surveillance tool for New Zealand workers. An iterative process of critical review was undertaken to create a dimensional framework and select specific measures from existing instruments. Pilot testing to ascertain participant acceptability of the questions was undertaken. The final questionnaire includes measures of socio-demographic characteristics, occupational history, work organisation, physicochemical, ergonomic and psychosocial hazards. Outcome measures were also included. A robust New Zealand hazard surveillance questionnaire comprehensively covering the key measures of work organisation and work environments that impact upon worker health and safety outcomes was developed. Recommended measures of work organisation, work environment and health outcomes that should be captured in work environment surveillance are made.

  18. A model surveillance program based on regulatory experience

    International Nuclear Information System (INIS)

    Conte, R.J.

    1980-01-01

    A model surveillance program is presented based on regulatory experience. The program consists of three phases: Program Delineation, Data Acquistion and Data Analysis. Each phase is described in terms of key quality assurance elements and some current philosophies is the United States Licensing Program. Other topics include the application of these ideas to test equipment used in the surveillance progam and audits of the established program. Program Delineation discusses the establishment of administrative controls for organization and the description of responsibilities using the 'Program Coordinator' concept, with assistance from Data Acquisition and Analysis Teams. Ideas regarding frequency of surveillance testing are also presented. The Data Acquisition Phase discusses various methods for acquiring data including operator observations, test procedures, operator logs, and computer output, for trending equipment performance. The Data Analysis Phase discusses the process for drawing conclusions regarding component/equipment service life, proper application, and generic problems through the use of trend analysis and failure rate data. (orig.)

  19. Analysis of anisotropic damage in forged Al–Cu–Mg–Si alloy based on creep tests, micrographs of fractured specimen and digital image correlations

    Energy Technology Data Exchange (ETDEWEB)

    Gariboldi, Elisabetta, E-mail: elisabetta.gariboldi@polimi.it [Politecnico di Milano, Department of Mechanical Engineering, Via La Masa 34 20156 Milano (Italy); Naumenko, Konstantin, E-mail: konstantin.naumenko@ovgu.de [Otto-von-Guericke-University Magdeburg, Institute of Mechanics, D-39106 Magdeburg (Germany); Ozhoga-Maslovskaja, Oksana, E-mail: oksana.ozhogamaslovskaja@gmail.com [Politecnico di Milano, Department of Mechanical Engineering, Via La Masa 34 20156 Milano (Italy); Zappa, Emanuele, E-mail: emanuele.zappa@polimi.it [Politecnico di Milano, Department of Mechanical Engineering, Via La Masa 34 20156 Milano (Italy)

    2016-01-15

    The aim of this paper is to analyze anisotropic damage mechanisms in forged Al–Cu–Mg–Si alloy based on the results of creep tests. Smooth specimens are sampled in three forging directions. Creep strain vs. time curves as well as light optical microscope and scanning electron microscope observations illustrate basic features of damage growth. Flat notch specimens are sampled in different directions to analyze stress redistributions and damage in zones of stress concentration. The digital image correlation technique has been applied in situ in order to extract the strain values on the surface of the notched specimens. All observations demonstrate that the principal origins of anisotropic creep and damage are associated with elongated grains and second phase clustered particles located at grain boundaries. Longitudinal specimens possess nucleations of decohesion sites and growth of voids around second phase particles at grain boundaries. Damage evolution for radial and transverse specimens is due to the formation and growth of cracks in second phase particles orthogonal to the principal stress axis. Residual strains are confined to the notch root as well as to the flanges of advanced macrocrack, indicating the small scale yielding during the creep fracture process.

  20. Prospective surveillance for influenza. virus in Chinese swine farms.

    Science.gov (United States)

    Anderson, Benjamin D; Ma, Mai-Juan; Wang, Guo-Lin; Bi, Zhen-Qiang; Lu, Bing; Wang, Xian-Jun; Wang, Chuang-Xin; Chen, Shan-Hui; Qian, Yan-Hua; Song, Shao-Xia; Li, Min; Zhao, Teng; Wu, Meng-Na; Borkenhagen, Laura K; Cao, Wu-Chun; Gray, Gregory C

    2018-05-16

    Pork production in China is rapidly increasing and swine production operations are expanding in size and number. However, the biosecurity measures necessary to prevent swine disease transmission, particularly influenza. viruses (IAV) that can be zoonotic, are often inadequate. Despite this risk, few studies have attempted to comprehensively study IAV ecology in swine production settings. Here, we present environmental and animal sampling data collected in the first year of an ongoing five-year prospective epidemiological study to assess IAV ecology as it relates to swine workers, their pigs, and the farm environment. From March 2015 to February 2016, we collected 396 each of environmental swab, water, bioaerosol, and fecal/slurry samples, as well as 3300 pig oral secretion samples from six farms in China. The specimens were tested with molecular assays for IAV. Of these, 46 (11.6%) environmental swab, 235 (7.1%) pig oral secretion, 23 (5.8%) water, 20 (5.1%) bioaerosol, and 19 (4.8%) fecal/slurry specimens were positive for influenza. by qRT-PCR. Risk factors for IAV detection among collected samples were identified using bivariate logistic regression. Overall, these first year data suggest that IAV is quite ubiquitous in the swine production environment and demonstrate an association between the different types of environmental sampling used. Given the mounting evidence that some of these viruses freely move between pigs and swine workers, and that mixing of these viruses can yield progeny viruses with pandemic potential, it seems imperative that routine surveillance for novel IAVs be conducted in commercial swine farms.

  1. Surveillance and laboratory detection for non-polio enteroviruses in the European Union/European Economic Area, 2016

    Science.gov (United States)

    Harvala, Heli; Jasir, Aftab; Penttinen, Pasi; Pastore Celentano, Lucia; Greco, Donato; Broberg, Eeva

    2017-01-01

    Enteroviruses (EVs) cause severe outbreaks of respiratory and neurological disease as illustrated by EV-D68 and EV-A71 outbreaks, respectively. We have mapped European laboratory capacity for identification and characterisation of non-polio EVs to improve preparedness to respond to (re)-emerging EVs linked to severe disease. An online questionnaire on non-polio EV surveillance and laboratory detection was submitted to all 30 European Union (EU)/European Economic Area (EEA) countries. Twenty-nine countries responded; 26 conducted laboratory-based non-polio EV surveillance, and 24 included neurological infections in their surveillance. Eleven countries have established specific surveillance for EV-D68 via sentinel influenza surveillance (n = 7), typing EV-positive respiratory samples (n = 10) and/or acute flaccid paralysis surveillance (n = 5). Of 26 countries performing non-polio EV characterisation/typing, 10 further characterised culture-positive EV isolates, whereas the remainder typed PCR-positive but culture-negative samples. Although 19 countries have introduced sequence-based EV typing, seven still rely entirely on virus isolation. Based on 2015 data, six countries typed over 300 specimens mostly by sequencing, whereas 11 countries characterised under 50 EV-positive samples. EV surveillance activity varied between EU/EEA countries, and did not always specifically target patients with neurological and/or respiratory infections. Introduction of sequence-based typing methods is needed throughout the EU/EEA to enhance laboratory capacity for the detection of EVs. PMID:29162204

  2. Final report : mobile surveillance and wireless communication systems field operational test. Volume 1, Executive summary

    Science.gov (United States)

    1999-03-01

    This study focused on assessing the application of traffic monitoring and management systems which use transportable surveillance and ramp meter trailers, video image processors, and wireless communications. The mobile surveillance and wireless commu...

  3. Validity of fracture toughness determined with small bend specimens

    International Nuclear Information System (INIS)

    Wallin, K.; Rintamaa, R.; Valo, M.

    1994-02-01

    This report considers the validity of fracture toughness estimates obtained with small bend specimens in relation to fracture toughness estimates obtained with large specimens. The study is based upon the analysis and comparison of actual test results. The results prove the validity of the fracture toughness determined based upon small bend specimens, especially when the results are only used to determine the fracture toughness transition temperature T o . In this case the possible error is typically less than 5 deg C and at most 10 deg C. It can be concluded that small bend specimens are very suitable for the estimation of fracture toughness in the case of brittle fracture, provided the results are corrected for statistical size effects. (orig.). (20 refs., 17 figs.)

  4. Malaria Surveillance - United States, 2015.

    Science.gov (United States)

    Mace, Kimberly E; Arguin, Paul M; Tan, Kathrine R

    2018-05-04

    malaria cases diagnosed in the United States has been increasing since the mid-1970s, the number of cases decreased by 208 from 2014 to 2015. Among the regions of acquisition (Africa, West Africa, Asia, Central America, the Caribbean, South America, Oceania, and the Middle East), the only region with significantly fewer imported cases in 2015 compared with 2014 was West Africa (781 versus 969). Plasmodium falciparum, P. vivax, P. ovale, and P. malariae were identified in 67.4%, 11.7%, 4.1%, and 3.1% of cases, respectively. Less than 1% of patients were infected by two species. The infecting species was unreported or undetermined in 12.9% of cases. CDC provided diagnostic assistance for 13.1% of patients with confirmed cases and tested 15.0% of P. falciparum specimens for antimalarial resistance markers. Of the U.S. resident patients who reported purpose of travel, 68.4% were visiting friends or relatives. A lower proportion of U.S. residents with malaria reported taking any chemoprophylaxis in 2015 (26.5%) compared with 2014 (32.5%), and adherence was poor in this group. Among the U.S residents for whom information on chemoprophylaxis use and travel region were known, 95.3% of patients with malaria did not adhere to or did not take a CDC-recommended chemoprophylaxis regimen. Among women with malaria, 32 were pregnant, and none had adhered to chemoprophylaxis. A total of 23 malaria cases occurred among U.S. military personnel in 2015. Three cases of malaria were imported from the approximately 3,000 military personnel deployed to an Ebola-affected country; two of these were not P. falciparum species, and one species was unspecified. Among all reported cases in 2015, 17.1% were classified as severe illnesses and 11 persons died, compared with an average of 6.1 deaths per year during 2000-2014. In 2015, CDC received 153 P. falciparum-positive samples for surveillance of antimalarial resistance markers (although certain loci were untestable for some samples); genetic

  5. Surveillance of avian influenza in the Caribbean through the Caribbean Animal Health Network: surveillance tools and epidemiologic studies.

    Science.gov (United States)

    Lefrançois, T; Hendrikx, P; Ehrhardt, N; Millien, M; Gomez, L; Gouyet, L; Gaidet, N; Gerbier, G; Vachiéry, N; Petitclerc, F; Carasco-Lacombe, C; Pinarello, V; Ahoussou, S; Levesque, A; Gongora, H V; Trotman, M

    2010-03-01

    The Caribbean region is considered to be at risk for avian influenza (AI) due to a large backyard poultry system, an important commercial poultry production system, the presence of migratory birds, and disparities in the surveillance systems. The Caribbean Animal Health Network (CaribVET) has developed tools to implement AI surveillance in the region with the goals to have 1) a regionally harmonized surveillance protocol and specific web pages for AI surveillance on www.caribvet.net, and 2) an active and passive surveillance for AI in domestic and wild birds. A diagnostic network for the Caribbean, including technology transfer and AI virus molecular diagnostic capability in Guadeloupe (real-time reverse transcription-polymerase chain reaction for the AI virus matrix gene), was developed. Between 2006 and 2009, 627 samples from four Caribbean countries were tested for three circumstances: importation purposes, following a clinical suspicion of AI, or through an active survey of wild birds (mainly waders) during the southward and northward migration periods in Guadeloupe. None of the samples tested were positive, suggesting a limited role of these species in the AI virus ecology in the Caribbean. Following low pathogenic H5N2 outbreaks in the Dominican Republic in 2007, a questionnaire was developed to collect data for a risk analysis of AI spread in the region through fighting cocks. The infection pathway of the Martinique commercial poultry sector by AI, through introduction of infected cocks, was designed, and recommendations were provided to the Caribbean Veterinary Services to improve cock movement control and biosecurity measures. The CaribVET and its organization allowed interaction between diagnostic and surveillance tools on the one hand and epidemiologic studies on the other, both of them developed in congruence with regional strategies. Together, these CaribVET activities contribute to strengthening surveillance of avian influenza virus (AIV) in the

  6. Study on Identification of Material Model Parameters from Compact Tension Test on Concrete Specimens

    Science.gov (United States)

    Hokes, Filip; Kral, Petr; Husek, Martin; Kala, Jiri

    2017-10-01

    Identification of a concrete material model parameters using optimization is based on a calculation of a difference between experimentally measured and numerically obtained data. Measure of the difference can be formulated via root mean squared error that is often used for determination of accuracy of a mathematical model in the field of meteorology or demography. The quality of the identified parameters is, however, determined not only by right choice of an objective function but also by the source experimental data. One of the possible way is to use load-displacement curves from three-point bending tests that were performed on concrete specimens. This option shows the significance of modulus of elasticity, tensile strength and specific fracture energy. Another possible option is to use experimental data from compact tension test. It is clear that the response in the second type of test is also dependent on the above mentioned material parameters. The question is whether the parameters identified within three-point bending test and within compact tension test will reach the same values. The presented article brings the numerical study of inverse identification of material model parameters from experimental data measured during compact tension tests. The article also presents utilization of the modified sensitivity analysis that calculates the sensitivity of the material model parameters for different parts of loading curve. The main goal of the article is to describe the process of inverse identification of parameters for plasticity-based material model of concrete and prepare data for future comparison with identified values of the material model parameters from different type of fracture tests.

  7. Relationship between strain and central deflection in small punch creep specimens

    International Nuclear Information System (INIS)

    Yang Zhen; Wang Zhiwen

    2003-01-01

    Acquiring information about creep strain directly from small punch creep tests is difficult because the deformation behaviour of the small punch specimen is complicated. A routine is suggested in the present paper to treat this problem indirectly. Based on a finite element analysis, it is proposed that the relationship of central deflection δ to central creep strain ε c of a specimen subjected to creep can be represented approximately by the relationship of central deflection δ to central (elastic-plastic) strain ε of a specimen not subjected to creep. With this hypothesis, the δ∼ε c relation of the small punch creep specimen is obtained by resorting to a rigid-plastic membrane stretch forming model. Finally, small punch creep test results are used to evaluate creep strain and creep strain rate by taking advantage of this δ∼ε c relation

  8. Extension of the RPV irradiation surveillance program of NPP GKN II by T0 approach

    International Nuclear Information System (INIS)

    Barthelmes, J.; Keim, E.; Hein, H.; Koenig, G.

    2015-01-01

    The nuclear power plant (NPP) Neckarwestheim II (GKN II) started operation in 1989 and was designed for 40 years of operation. During the plant life time the reactor pressure vessel (RPV) integrity is a main aspect for nuclear safety since the RPV is exposed to neutron irradiation affecting the mechanical material properties, in particular toughness. In this context the ductile to brittle transition reference temperature of the RPV materials can be determined either indirectly according to the RT(NDT) concept by means of comparative examinations of irradiated and unirradiated notched-bar impact specimens or directly according to the Master Curve concept by means of examination of irradiated fracture mechanic specimens and determination of an alternative reference temperature RT(T0). With the implementation and evaluation of the first irradiation surveillance program consisting of three sets, one unirradiated reference set (set 1) and two irradiated sets (set 2 and 3), the RPV safety could be proven for the assessment fluence (AF) of 8*10 18 cm -2 (E > 1 MeV) using the RT(NDT) concept. Against the background of a possible long term operation and the state-of-the-art of science and technology in 1998 the NPP GKN II initiated a supplemental irradiation surveillance program with two irradiation sets (set 4 and 5) containing fracture mechanic specimens for complementary proof of safety according to the Master Curve concept. The results of the first irradiated set 4 are presented and assessed by means of the reference temperatures according to the Master Curve concept and compared to the results of the irradiation sets 1 to 3 of the conventional irradiation surveillance program. As an important outcome the existing RPV integrity assessment could be ensured by the Master Curve results. The applied approach adapts to the state-of-the-art of science and technology and is best practice to ensure the safe operation of RPV supplementary. (authors)

  9. Student Drug Testing and the Surveillance School Economy: An Analysis of Media Representation and Policy Transfer in Australian Schools

    Science.gov (United States)

    Taylor, Emmeline

    2018-01-01

    Anxieties relating to the health, safety and security of schoolchildren have been met with a variety of surveillance apparatus in schools internationally. Drawing on findings from a content analysis of newspaper reports relating to drug testing in Australian schools, this article seeks to excavate the ways in which the media shapes, informs,…

  10. Mapping of the US Domestic Influenza Virologic Surveillance Landscape.

    Science.gov (United States)

    Jester, Barbara; Schwerzmann, Joy; Mustaquim, Desiree; Aden, Tricia; Brammer, Lynnette; Humes, Rosemary; Shult, Pete; Shahangian, Shahram; Gubareva, Larisa; Xu, Xiyan; Miller, Joseph; Jernigan, Daniel

    2018-07-17

    Influenza virologic surveillance is critical each season for tracking influenza circulation, following trends in antiviral drug resistance, detecting novel influenza infections in humans, and selecting viruses for use in annual seasonal vaccine production. We developed a framework and process map for characterizing the landscape of US influenza virologic surveillance into 5 tiers of influenza testing: outpatient settings (tier 1), inpatient settings and commercial laboratories (tier 2), state public health laboratories (tier 3), National Influenza Reference Center laboratories (tier 4), and Centers for Disease Control and Prevention laboratories (tier 5). During the 2015-16 season, the numbers of influenza tests directly contributing to virologic surveillance were 804,000 in tiers 1 and 2; 78,000 in tier 3; 2,800 in tier 4; and 3,400 in tier 5. With the release of the 2017 US Pandemic Influenza Plan, the proposed framework will support public health officials in modeling, surveillance, and pandemic planning and response.

  11. Influence of specimen type and reinforcement on measured tension-tension fatigue life of unidirectional GFRP laminates

    DEFF Research Database (Denmark)

    Korkiakoski, Samuli; Brøndsted, Povl; Sarlin, Essi

    2016-01-01

    It is well known that standardised tension-tension fatigue test specimens of unidirectional (UD) glass-fibre-reinforced plastics (GFRP) laminates tend to fail at end tabs. The true fatigue life is then underestimated. The first objective of this study was to find for UD GFRP laminates a test...... specimen that fails in the gauge section. The second objective was to compare fatigue performance of two laminates, one having a newly developed UD powder-bound fabric as a reinforcement and the other having a quasi-UD stitched non-crimp fabric as a reinforcement. In the first phase, a rectangular specimen...... in accordance with the ISO 527-5 standard and two slightly different dog-bone shaped specimens were evaluated by means of finite element modelling. Subsequent comparative fatigue tests were performed for the laminates with the three specimen types. The results showed that the test specimen type has...

  12. Environmental charging of spacecraft-tests of thermal control materials for use on the global positioning system flight space vehicle. Part 2: Specimen 6 to 9

    Science.gov (United States)

    Stevens, N. J.; Berkopec, F. D.; Blech, R. A.

    1976-01-01

    The NASA/USAF program on the Environmental Charging of Spacecraft Surfaces consists, in part, of experimental efforts directed toward evaluating the response of materials to the environmental charged particle flux. Samples of thermal blankets of the type to be used on the Global Positioning System Flight Space Vehicles were tested to determine their response to electron flux. The primary result observed was that no discharges were obtained with the quartz-fiber-fabric-covered multilayer insulation specimen. The taped aluminized polyester grounding system used on all specimens did not appear to grossly deteriorate with time; however, the specimens require specific external pressure to maintain constant grounding system resistance.

  13. Reassembling Surveillance Creep

    DEFF Research Database (Denmark)

    Bøge, Ask Risom; Lauritsen, Peter

    2017-01-01

    We live in societies in which surveillance technologies are constantly introduced, are transformed, and spread to new practices for new purposes. How and why does this happen? In other words, why does surveillance “creep”? This question has received little attention either in theoretical developm......We live in societies in which surveillance technologies are constantly introduced, are transformed, and spread to new practices for new purposes. How and why does this happen? In other words, why does surveillance “creep”? This question has received little attention either in theoretical...... development or in empirical analyses. Accordingly, this article contributes to this special issue on the usefulness of Actor-Network Theory (ANT) by suggesting that ANT can advance our understanding of ‘surveillance creep’. Based on ANT’s model of translation and a historical study of the Danish DNA database......, we argue that surveillance creep involves reassembling the relations in surveillance networks between heterogeneous actors such as the watchers, the watched, laws, and technologies. Second, surveillance creeps only when these heterogeneous actors are adequately interested and aligned. However...

  14. Intraoperative specimen radiography in patients with nonpalpable malignant breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Schmachtenberg, C.; Engelken, F.; Fischer, T.; Bick, U.; Poellinger, A.; Fallenberg, E.M. [Charite, Berlin (Germany). Radiology

    2012-07-15

    Purpose: Specimen mammography of nonpalpable wire-localized breast lesions is the standard in breast-conserving surgery. The aim of this study was to evaluate the reliability of intraoperative 2-view specimen mammography in different cancer types. Materials and Methods: After ethics approval, 3 readers retrospectively evaluated margins on 266 2-view specimen radiographs. They determined the closest margin and the orientation. The results were correlated with the histopathology (intra-class correlation coefficient [ICC] and contingency coefficient [CC]) and compared (Wilcoxon test). Results: Invasive ductal carcinoma (IDC) with ductal carcinoma in situ (DCIS) was present in 115 (43 %), IDC in 75 (28 %), invasive lobular carcinoma (ILC) in 57 (22 %) and rare cancers (CA) in 19 specimens (7 %). The sensitivity/specificity and positive/negative predictive value (P/NPV) of specimen mammography were 0.50/0.86 and 0.86/0.50 for CA, 0.42/0.68 and 0.48/0.63 for IDC, 0.36/0.81 and 0.69/0.51 for ILC, and 0.22/0.78 and 0.68/0.32 for IDC+DCIS. Readers correctly identified the orientation of the closest margin in at least one view in an average of 149 specimens (56 %). CCs were between 0.680 (IDC) and 0.912 (CA), suggesting a moderate correlation between radiographic and histological orientation. The correlations were worse for the radiographic and histological distances, with ICC ranging from 0.238 (ILC) to 0.475 (CA). The Wilcoxon test revealed overestimation of the radiographic margins compared to the histological ones for DCIS. Conclusion: Our results suggest that specimen radiography has relatively good overall specificity and good PPV, while the sensitivity and NPV are low for DCIS. A negative result on specimen radiography does not rule out histologically involved margins. (orig.)

  15. Intraoperative specimen radiography in patients with nonpalpable malignant breast lesions.

    Science.gov (United States)

    Schmachtenberg, C; Engelken, F; Fischer, T; Bick, U; Poellinger, A; Fallenberg, E M

    2012-07-01

    Specimen mammography of nonpalpable wire-localized breast lesions is the standard in breast-conserving surgery. The aim of this study was to evaluate the reliability of intraoperative 2-view specimen mammography in different cancer types. After ethics approval, 3 readers retrospectively evaluated margins on 266 2-view specimen radiographs. They determined the closest margin and the orientation. The results were correlated with the histopathology (intra-class correlation coefficient [ICC] and contingency coefficient [CC]) and compared (Wilcoxon test). Invasive ductal carcinoma (IDC) with ductal carcinoma in situ (DCIS) was present in 115 (43 %), IDC in 75 (28 %), invasive lobular carcinoma (ILC) in 57 (22 %) and rare cancers (CA) in 19 specimens (7 %). The sensitivity/specificity and positive/negative predictive value (P/NPV) of specimen mammography were 0.50/0.86 and 0.86/0.50 for CA, 0.42/0.68 and 0.48/0.63 for IDC, 0.36/0.81 and 0.69/0.51 for ILC, and 0.22/0.78 and 0.68/0.32 for IDC+DCIS. Readers correctly identified the orientation of the closest margin in at least one view in an average of 149 specimens (56 %). CCs were between 0.680 (IDC) and 0.912 (CA), suggesting a moderate correlation between radiographic and histological orientation. The correlations were worse for the radiographic and histological distances, with ICC ranging from 0.238 (ILC) to 0.475 (CA). The Wilcoxon test revealed overestimation of the radiographic margins compared to the histological ones for DCIS. Our results suggest that specimen radiography has relatively good overall specificity and good PPV, while the sensitivity and NPV are low for DCIS. A negative result on specimen radiography does not rule out histologically involved margins. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Intraoperative specimen radiography in patients with nonpalpable malignant breast lesions

    International Nuclear Information System (INIS)

    Schmachtenberg, C.; Engelken, F.; Fischer, T.; Bick, U.; Poellinger, A.; Fallenberg, E.M.

    2012-01-01

    Purpose: Specimen mammography of nonpalpable wire-localized breast lesions is the standard in breast-conserving surgery. The aim of this study was to evaluate the reliability of intraoperative 2-view specimen mammography in different cancer types. Materials and Methods: After ethics approval, 3 readers retrospectively evaluated margins on 266 2-view specimen radiographs. They determined the closest margin and the orientation. The results were correlated with the histopathology (intra-class correlation coefficient [ICC] and contingency coefficient [CC]) and compared (Wilcoxon test). Results: Invasive ductal carcinoma (IDC) with ductal carcinoma in situ (DCIS) was present in 115 (43 %), IDC in 75 (28 %), invasive lobular carcinoma (ILC) in 57 (22 %) and rare cancers (CA) in 19 specimens (7 %). The sensitivity/specificity and positive/negative predictive value (P/NPV) of specimen mammography were 0.50/0.86 and 0.86/0.50 for CA, 0.42/0.68 and 0.48/0.63 for IDC, 0.36/0.81 and 0.69/0.51 for ILC, and 0.22/0.78 and 0.68/0.32 for IDC+DCIS. Readers correctly identified the orientation of the closest margin in at least one view in an average of 149 specimens (56 %). CCs were between 0.680 (IDC) and 0.912 (CA), suggesting a moderate correlation between radiographic and histological orientation. The correlations were worse for the radiographic and histological distances, with ICC ranging from 0.238 (ILC) to 0.475 (CA). The Wilcoxon test revealed overestimation of the radiographic margins compared to the histological ones for DCIS. Conclusion: Our results suggest that specimen radiography has relatively good overall specificity and good PPV, while the sensitivity and NPV are low for DCIS. A negative result on specimen radiography does not rule out histologically involved margins. (orig.)

  17. Using Acute Flaccid Paralysis Surveillance as a Platform for Vaccine-Preventable Disease Surveillance.

    Science.gov (United States)

    Wassilak, Steven G F; Williams, Cheryl L; Murrill, Christopher S; Dahl, Benjamin A; Ohuabunwo, Chima; Tangermann, Rudolf H

    2017-07-01

    Surveillance for acute flaccid paralysis (AFP) is a fundamental cornerstone of the global polio eradication initiative (GPEI). Active surveillance (with visits to health facilities) is a critical strategy of AFP surveillance systems for highly sensitive and timely detection of cases. Because of the extensive resources devoted to AFP surveillance, multiple opportunities exist for additional diseases to be added using GPEI assets, particularly because there is generally 1 district officer responsible for all disease surveillance. For this reason, integrated surveillance has become a standard practice in many countries, ranging from adding surveillance for measles and rubella to integrated disease surveillance for outbreak-prone diseases (integrated disease surveillance and response). This report outlines the current level of disease surveillance integration in 3 countries (Nepal, India, and Nigeria) and proposes that resources continue for long-term maintenance in resource-poor countries of AFP surveillance as a platform for surveillance of vaccine-preventable diseases and other outbreak-prone diseases. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  18. An Experimental Study of Shear-Dominated Failure in the 2013 Sandia Fracture Challenge Specimen

    Energy Technology Data Exchange (ETDEWEB)

    Corona, Edmundo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Deibler, Lisa Anne [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Reedlunn, Benjamin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ingraham, Mathew Duffy [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Williams, Shelley [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-04-01

    This report presents an experimental study motivated by results obtained during the 2013 Sandia Fracture Challenge. The challenge involved A286 steel, shear-dominated compression specimens whose load-deflection response contained a load maximum fol- lowed by significant displacement under decreasing load, ending with a catastrophic fracture. Blind numerical simulations deviated from the experiments well before the maximum load and did not predict the failure displacement. A series of new tests were conducted on specimens machined from the original A286 steel stock to learn more about the deformation and failure processes in the specimen and potentially improve future numerical simulations. The study consisted of several uniaxial tension tests to explore anisotropy in the material, and a set of new tests on the compression speci- men. In some compression specimen tests, stereo digital image correlation (DIC) was used to measure the surface strain fields local to the region of interest. In others, the compression specimen was loaded to a given displacement prior to failure, unloaded, sectioned, and imaged under the microscope to determine when material damage first appeared and how it spread. The experiments brought the following observations to light. The tensile tests revealed that the plastic response of the material is anisotropic. DIC during the shear- dominated compression tests showed that all three in-plane surface strain components had maxima in the order of 50% at the maximum load. Sectioning of the specimens revealed no signs of material damage at the point where simulations deviated from the experiments. Cracks and other damage did start to form approximately when the max- imum load was reached, and they grew as the load decreased, eventually culminating in catastrophic failure of the specimens. In addition to the steel specimens, a similar study was carried out for aluminum 7075-T651 specimens. These specimens achieved much lower loads and displacements

  19. Redefining syndromic surveillance

    Directory of Open Access Journals (Sweden)

    Rebecca Katz

    2011-12-01

    Full Text Available With growing concerns about international spread of disease and expanding use of early disease detection surveillance methods, the field of syndromic surveillance has received increased attention over the last decade. The purpose of this article is to clarify the various meanings that have been assigned to the term syndromic surveillance and to propose a refined categorization of the characteristics of these systems. Existing literature and conference proceedings were examined on syndromic surveillance from 1998 to 2010, focusing on low- and middle-income settings. Based on the 36 unique definitions of syndromic surveillance found in the literature, five commonly accepted principles of syndromic surveillance systems were identified, as well as two fundamental categories: specific and non-specific disease detection. Ultimately, the proposed categorization of syndromic surveillance distinguishes between systems that focus on detecting defined syndromes or outcomes of interest and those that aim to uncover non-specific trends that suggest an outbreak may be occurring. By providing an accurate and comprehensive picture of this field’s capabilities, and differentiating among system types, a unified understanding of the syndromic surveillance field can be developed, encouraging the adoption, investment in, and implementation of these systems in settings that need bolstered surveillance capacity, particularly low- and middle-income countries.

  20. Weld investigations by 3D analyses of Charpy V-notch specimens

    DEFF Research Database (Denmark)

    Tvergaard, Viggo; Needleman, Allan

    2005-01-01

    The Charpy impact test is a standard procedure for determining the ductile-brittle transition in welds. The predictions of such tests have been investigated by full three dimensional transient analyses of Charpy V-notch specimens. The material response is characterised by an elastic...... parameters in the weld material differ from those in the base material, and the heat a®ected zone (HAZ) tends to be more brittle than the other material regions. The effect of weld strength undermatch or overmatch is an important issue. Some specimens, for which the notched surface is rotated relative...... to the surface of the test piece, have so complex geometry that only a full 3D analysis is able to account for the interaction of failure in the three different material regions, whereas ther specimens can be approximated in terms of a planar analysis....

  1. Detection of macrolide resistance genes in culture-negative specimens from Bangladeshi children with invasive pneumococcal diseases.

    Science.gov (United States)

    Hasanuzzaman, Md; Malaker, Roly; Islam, Maksuda; Baqui, Abdullah H; Darmstadt, Gary L; Whitney, Cynthia G; Saha, Samir K

    2017-03-01

    In recent years, an increasing prevalence of macrolide resistance among pneumococci in Bangladesh has been observed. However, the scenario remains incomplete, as few isolates (80%) are culture-negative. This study optimised a triplex PCR method to detect macrolide resistance genes (MRGs) (mefA and ermB) and cpsA from culture-negative pneumococcal cases to predict the prevalence and level of macrolide resistance. The presence of MRGs among pneumococcal strains (n=153) with a wide range of erythromycin MICs (culture-negative clinical specimens and corresponding isolates. The known impact of the presence of specific MRG(s) on MICs of strains was used to predict the MICs of non-culturable strains based on the presence/absence of MRG(s) in the specimens. None of the erythromycin-susceptible isolates possessed any of the MRGs, and all non-susceptible strains had ≥1 MRG. MICs were 2-16mg/L and ≥256mg/L for 93% of strains with mefA and ermB, respectively, whereas 100% of isolates with both genes had MICs≥256mg/L. PCR for body fluids showed 100% concordance with corresponding isolates when tested for MRG(s) in parallel. Erythromycin MICs can be predicted for non-culturable strains with 93-100% precision based on detection of ermB and/or mefA. This method will be useful for establishing comprehensive surveillance for macrolide resistance among pneumococci, specifically in the population with prior antibiotic use. Copyright © 2017. Published by Elsevier Ltd.

  2. Examination of the fatigue life under combined loading of specimens

    Directory of Open Access Journals (Sweden)

    Fojtík F.

    2008-11-01

    Full Text Available This contribution describes experimental results under combined loading of specimens manufactured from common construction steel 11523. Specimens were gradually loaded by amplitude of the torque, then by combination of torque and tension prestress. The last set of specimens was loaded in combination of torque and inner overpressure. To obtain the required input values the stress-strain analysis of specimens by finite element method in software Ansys was performed within the last experiment. For evaluation of the results the Fuxa's criterion was applied. The performed experiments and their results embody a good agreement with bellow mentioned conjugated strength criterion. The experiments were performed on reconstructed testing machine equipped by pressure chamber.

  3. MARGINAL EXPENSE OIL WELL WIRELESS SURVEILLANCE MEOWS

    Energy Technology Data Exchange (ETDEWEB)

    Mason M. Medizade; John R. Ridgely; Donald G. Nelson

    2004-11-01

    A marginal expense oil well wireless surveillance system to monitor system performance and production from rod-pumped wells in real time from wells operated by Vaquero Energy in the Edison Field, Main Area of Kern County in California has been successfully designed and field tested. The surveillance system includes a proprietary flow sensor, a programmable transmitting unit, a base receiver and receiving antenna, and a base station computer equipped with software to interpret the data. First, the system design is presented. Second, field data obtained from three wells is shown. Results of the study show that an effective, cost competitive, real-time wireless surveillance system can be introduced to oil fields across the United States and the world.

  4. Self-Collected Nasal Swabs for Respiratory Virus Surveillance

    Science.gov (United States)

    Jackson, Michael L.; Nguyen, Matthew; Kirlin, Beth; Madziwa, Lawrence

    2015-01-01

    We tested whether 135 patients reporting acute respiratory illness (ARI) could self-collect nasal swab specimens and ship them for laboratory testing. Most subjects (78.2%) collected and shipped their specimens without errors; 10.5% excluded ≥1 packing components; 12.9% made ≥1 packing errors. Self-swabbing at home is feasible for confirming ARI etiology. PMID:26613095

  5. Finite strain analyses of deformations in polymer specimens

    DEFF Research Database (Denmark)

    Tvergaard, Viggo

    2016-01-01

    Analyses of the stress and strain state in test specimens or structural components made of polymer are discussed. This includes the Izod impact test, based on full 3D transient analyses. Also a long thin polymer tube under internal pressure has been studied, where instabilities develop, such as b...

  6. Fracture toughness evaluation using circumferential notched tensile specimens by the tensile test and ANSYS software

    Energy Technology Data Exchange (ETDEWEB)

    Meydanlik, N. [Mechanical Engineering Department, Trakya University, Edirne (Turkey)

    2013-07-01

    Fracture toughness (K{sub Ic} ) is the most important parameter that defines mechanical behaviour of the materials using machine design. Since, fracture tests are both difficult and time consuming, the researchers have been investigating for the easier evaluation of K{sub Ic} for many years. In this work; K{sub Ic} values have been obtained by using ANSYS software based on the experimental values evaluated in the previous studies. It was shown that there is no significant difference between the experimental ones and the ones obtained by ANSYS. This procedure can provide an important advantage on obtaining of the K{sub IC} values. Key words: Fracture toughness (K{sub Ic} ), circumferential notched tensile specimens, ANSYS.

  7. Instrumentation of a Charpy-pendulum. Additional data obtained from it and its application to nuclear reactor pressure vessels surveillance programs; Instrumentacion de un pendulo Charpy. Datos adicionales obtenidos a partir de la misma y su aplicacion a programas de vigilancia de centrales nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Chomik, Enrique P; Dhers, Horacio; Iorio, Antonio F [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Materiales; Ciriani, Dario F [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Combustibles Nucleares

    1999-07-01

    Charpy test gives information about a material dynamic fracture behavior. In a plain Charpy test, this information is the absorbed energy during fracture of the specimen, lateral deformation and the percentage of ductile fracture of the specimen. These parameters can then be used for the determination of the material response to a dynamic applied load, and are used at present to determine the brittle-ductile transition temperature of a material. However, there is a lot of additional information that can be obtained from a Charpy test, which is vital for the case of surveillance programs of nuclear power plants, where it is necessary to get the most available information from the specimens to be tested, because each one of them was irradiated for many years under temperature and neutronic flux conditions similar to that of the internal surface of the reactor pressure vessel, which converts these specimens in unique and very expensive ones. This additional information can be obtained from the curve that determines the evolution of the applied force to the specimen throughout the time involved in its fracture. It was possible to instrument a Charpy pendulum at a fraction of the cost necessary to buy an instrumentation package like the ones available in the market, and since the instrumentation equipment obtained is easy to transport. It has the additional advantage that can be used to instrument any other pendulum replacing only the hammer of the pendulum with a instrumented one for that pendulum. (author)

  8. Definition of the minimum longitude of insert in the rebuilding of Charpy test tubes for surveillance and life extension of vessels in Mexico

    International Nuclear Information System (INIS)

    Romero C, J.; Hernandez C, R.; Rocamontes A, M.

    2011-11-01

    In the National Institute of Nuclear Research (Mexico) a welding system for the rebuilding of Charpy test tubes has been developed, automated, qualified and used for the surveillance of the mechanical properties (mainly embrittlement) of the vessel. This system uses the halves of the rehearsed Charpy test tubes of the surveillance capsules extracted of the reactors, to obtain, of a rehearsed test tube, two reconstituted test tubes. This rebuilding process is used so much in the surveillance program like in the potential extension of the operation license of the vessel. To the halves of Charpy test tubes that have been removed the deformed part by machine are called -insert- and in a very general way the rebuilding consists in weld with the welding process -Stud Welding- two metallic implants in the ends of the insert, to obtain a reconstituted test tube. The main characteristic of this welding are the achieved small dimensions, so much of the areas welded as of the areas affected by the heat. The applicable normative settles down that the minim longitude of the insert for the welding process by Stud Welding it should be of 18 mm, however according to the same normative this longitude can diminish if is demonstrated analytic or experimentally that the central volume of 1 cm 3 in the insert is not affected. In this work the measurement of the temperature profiles to different distances of the welding interface is presented, defining an equation for the maximum temperatures reached in function of the distance, on the other hand the real longitude affected in the test tube by means of metallography is determined and this way the minimum longitude of the insert for this developed rebuilding system was determined. (Author)

  9. The plays and arts of surveillance: studying surveillance as entertainment

    NARCIS (Netherlands)

    Albrechtslund, Anders; Dubbeld, L.

    2006-01-01

    This paper suggests a direction in the development of Surveillance Studies that goes beyond current attention for the caring, productive and enabling aspects of surveillance practices. That is, surveillance could be considered not just as positively protective, but even as a comical, playful,

  10. Surveillance mission planning for UAVs in GPS-denied urban environment

    Science.gov (United States)

    Pengfei, Wang

    In this thesis, the issues involved in the mission planning of UAVs for city surveillance have been studied. In this thesis, the research includes two major parts. Firstly, a mission planning system is developed that generates mission plans for a group of fixed-wing UAVs with on-board gimballed cameras to provide continuous surveillance over an urban area. Secondly, the problem of perching location selection (as part of perch-and-stare surveillance mission) for rotary-wing UAVs in a GPS-denied environment is studied. In this kind of mission, a UAV is dispatched to perch on a roof of a building to keep surveillance on a given target. The proposed algorithms to UAV surveillance mission planning (fixed-wing and rotary-wing) have been implemented and tested. It represents an important step towards achieving autonomous planning in UAV surveillance missions.

  11. Thinning of specimens for examination under the electron microscope

    International Nuclear Information System (INIS)

    Franks, J.

    1982-01-01

    Heretofore specimens have been thinned to penetration for examination by electron microscopy techniques, by ion erosion techniques. A more rapid technique is disclosed employing a beam or beams comprised solely of neutral particles. In tests carried out using this technique the sputtering rate from a sample specimen has been shown to be several percentages greater using a neutral source than from an ion source with the same flux density. (author)

  12. Multiplex PCR-based assay for detection of Bordetella pertussis in nasopharyngeal swab specimens.

    Science.gov (United States)

    Wadowsky, R M; Michaels, R H; Libert, T; Kingsley, L A; Ehrlich, G D

    1996-11-01

    A multiplex PCR-based assay was developed for the detection of Bordetella pertussis in nasopharyngeal swab specimens. The assay simultaneously amplified two separate DNA targets (153 and 203 bp) within a B. pertussis repetitive element and a 438-bp target within the beta-actin gene of human DNA (PCR amplification control). PCR products were detected by a sensitive and specific liquid hybridization gel retardation assay. A total of 496 paired nasopharyngeal swab specimens were tested by both the PCR-based assay and culture. Although 30 (6%) of the specimens inhibited the amplification of the beta-actin target, in all 29 specimens studied, the inhibition disappeared on repeat testing or was easily overcome with a 1:8 dilution or less of specimen digest. Of the 495 specimen pairs yielding a final evaluable result by the PCR-based assay, 19.0% were positive by the PCR-based assay, whereas 13.9% were positive by culture (P < 0.0001). After resolving the PCR-positive, culture-negative results by testing an additional aliquot from these specimens by the multiplex PCR-based assay, the PCR-based assay had a sensitivity and specificity of 98.9 and 99.7%, respectively, compared with values of 73.4 and 100%, respectively, for culture. In comparison with patients with culture-confirmed pertussis, those with PCR-positive, culture-negative results were older and more likely to have had prolonged cough, immunization with pertussis vaccine, or treatment with erythromycin. This multiplex PCR-based assay is substantially more sensitive than culture and identifies specimens that contain inhibitors of PCR.

  13. Crashworthiness Analysis and Evaluation of Fuselage Section with Sub-floor Composite Sinusoidal Specimens

    Directory of Open Access Journals (Sweden)

    H.L. Mou

    Full Text Available Abstract Crashworthiness is one of the main concerns in civil aviation safety particularly with regard to the increasing ratio of carbon fiber reinforced plastic (CFRP in aircraft primary structures. In order to generate dates for model validations, the mechanical properties of T700/3234 were obtained by material performance tests, and energy-absorbing results were gained by quasi-static crushing tests of composite sinusoidal specimens. The correctness of composite material model and single-layer finite element model of composite sinusoidal specimens were verified based on the simulation results and test results that were in good agreement. A typical civil aircraft fuselage section with composite sinusoidal specimens under cargo floor was suggested. The crashworthiness of finite element model of fuselage section was assessed by simulating the vertical drop test subjected to 7 m/s impact velocity, and the influences of different thickness of sub-floor composite sinusoidal specimens on crashworthiness of fuselage section were also analyzed. The simulation results show that the established finite element model can accurately simulate the crushing process of composite sinusoidal specimens; the failure process of fuselage section is more stable, and the safety of occupants can be effectively improved because of the smaller peak accelerations that was limited to human tolerance, a critical thickness of sub-floor composite sinusoidal specimens can restrict the magnitude of acceleration peaks, which has certain reference values for enhancing crashworthiness capabilities of fuselage section and improving the survivability of passengers.

  14. Fatigue test results of flat plate specimens with surface cracks and evaluation of crack growth in structural components

    International Nuclear Information System (INIS)

    Shibata, Katsuyuki; Yokoyama, Norio; Ohba, Toshihiro; Kawamura, Takaichi; Miyazono, Shohachiro

    1982-12-01

    Part-through surface cracks are most frequently observed in the inspection of structural components, and it is one of the important subjects in the assessment of safety to evaluate appropriately the growth of such cracks during the service life of structural components. Due to the complexity of the stress at the front free surface, the crack growth at the surface shows a different behavior from the other part. Besides, an effect of interaction is caused in the growth of multiple surface cracks. These effects should be included in the growth analysis of surface part-through cracks. Authors have carried out a series of fatigue tests on some kinds of pipes with multiple cracks in the inner surface, and subsequently the fatigue test of flat plate specimens, made of Type 304L stainless steel, with a single or double surface cracks was carried out to study the basic characteristics in the growth of multiple surface cracks. Based on the results of the flat plate test. the correction factors for the front free surface (Cs) and interaction (Ci) of surface cracks were derived quantitatively by the following empirical expressions; Cs = 0.824. Ci = (0.227(a/b) 2 (sec(PI X/2) - 1) + 1)sup(1/m). Using these two correction factors, a procedure to predict the growth of surface cracks was developed by applying the crack growth formula to both the thickness and surface directions. Besides, the crack growth predictions based on the procedure of ASME Code Sex. XI, and the above procedure without the correction of the free surface and interactions on the crack growth behaviors were compared with the test results of flat plate specimens. The crack growth behavior predicted by the procedure described in this report showed the best agreement with the test results in respects of the crack growth life and the change in the crack shape. The criteria of the ASME Code did not agree with the test results. (author)

  15. Effect of sized and specimen geometry on the initiation and propagation of the ductile fracture

    International Nuclear Information System (INIS)

    Frund, J.M.; Marini, B.; Bethmont, M.

    1994-02-01

    Strength to the fracture of the pipe in PWR has to be justified with mechanical analyses. These tests are based on the strength to ductile fracture of steels which are tested in lab. The values of resistance to fracture are obtained through tensile tests on CT specimens (determination of J-R curves). The purpose of this study is to justify the sizes of the specimens which have to be used to characterize the strength to ductile fracture of steel in secondary pipes. Tests were conducted on 0,5T-CT, 1T-CT and 2T-CT specimens. Two materials with different suffer contents were studied. The test results show that the JO,2 values gotten from the different specimens are similar. But the strength to ductile fracture in 2T-CT specimens in lower than the one measured in 0,5t-CT and 1T-CT specimens. The surface of fracture of the different specimens displays splits perpendicular to the notch and parallel to the sheet surface. These splits are produced by the separation of the manganese sulfur inclusions. The effect notes on the J-R curves seems to be relevant to these splits. The reason why these splits might be responsible for a decrease of the tearing modulus are not clearly defined up to this point. The results which have been published show the importance of the geometry effects (presence or not of lateral notches...) and the loading mode on the strength to ductile fracture. We note that the curves determined from tests on CT specimens are conservative. A few preliminary studies showed that the geometry effects on resistance to fracture can be studied and explained by using local approach methods. The Rousselier modeling is useful to explain the behaviour of ferritic steels in ductile fracture. (authors). 20 refs., 7 figs., 5 tabs

  16. Miniaturization of specimens for mechanical testing

    International Nuclear Information System (INIS)

    Harling, O.K.; Kohse, G.

    1987-01-01

    The development of mechanical property tests based on bending of a 3 mm diameter by (typically) 0.25 mm thick disk is described. Slow strain rate testing of such a disk is used to obtain tensile properties. Finite element computer modelling is used to extract yield stress values with accuracies of at least +- 10% of uniaxial tensile test values for a variety of materials. Analytical estimates of ductility from disk bend test values are possible for low-ductility materials. Work directed toward finite element calculations for ductility and ultimate tensile strength is also discussed. Preliminary data indicating the feasibility of high strain rate testing for estimation of ductile-to-brittle transition temperatures, and an example of the successful application of miniature bend testing in obtaining relative fatigue information are also presented. (author)

  17. Secure Video Surveillance System (SVSS) for unannounced safeguards inspections

    International Nuclear Information System (INIS)

    Galdoz, Erwin G.; Pinkalla, Mark

    2010-01-01

    The Secure Video Surveillance System (SVSS) is a collaborative effort between the U.S. Department of Energy (DOE), Sandia National Laboratories (SNL), and the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC). The joint project addresses specific requirements of redundant surveillance systems installed in two South American nuclear facilities as a tool to support unannounced inspections conducted by ABACC and the International Atomic Energy Agency (IAEA). The surveillance covers the critical time (as much as a few hours) between the notification of an inspection and the access of inspectors to the location in facility where surveillance equipment is installed. ABACC and the IAEA currently use the EURATOM Multiple Optical Surveillance System (EMOSS). This outdated system is no longer available or supported by the manufacturer. The current EMOSS system has met the project objective; however, the lack of available replacement parts and system support has made this system unsustainable and has increased the risk of an inoperable system. A new system that utilizes current technology and is maintainable is required to replace the aging EMOSS system. ABACC intends to replace one of the existing ABACC EMOSS systems by the Secure Video Surveillance System. SVSS utilizes commercial off-the shelf (COTS) technologies for all individual components. Sandia National Laboratories supported the system design for SVSS to meet Safeguards requirements, i.e. tamper indication, data authentication, etc. The SVSS consists of two video surveillance cameras linked securely to a data collection unit. The collection unit is capable of retaining historical surveillance data for at least three hours with picture intervals as short as 1sec. Images in .jpg format are available to inspectors using various software review tools. SNL has delivered two SVSS systems for test and evaluation at the ABACC Safeguards Laboratory. An additional 'proto-type' system remains

  18. Nationwide surveillance of bacterial respiratory pathogens conducted by the surveillance committee of Japanese Society of Chemotherapy, the Japanese Association for Infectious Diseases, and the Japanese Society for Clinical Microbiology in 2012: General view of the pathogens' antibacterial susceptibility.

    Science.gov (United States)

    Yanagihara, Katsunori; Watanabe, Akira; Aoki, Nobuki; Matsumoto, Tetsuya; Yoshida, Masaki; Sato, Junko; Wakamura, Tomotaro; Sunakawa, Keisuke; Kadota, Junichi; Kiyota, Hiroshi; Iwata, Satoshi; Kaku, Mitsuo; Hanaki, Hideaki; Ohsaki, Yoshinobu; Fujiuchi, Satoru; Takahashi, Manabu; Takeuchi, Kenichi; Takeda, Hiroaki; Ikeda, Hideki; Miki, Makoto; Nakanowatari, Susumu; Takahashi, Hiroshi; Utagawa, Mutsuko; Nishiya, Hajime; Kawakami, Sayoko; Morino, Eriko; Takasaki, Jin; Mezaki, Kazuhisa; Chonabayashi, Naohiko; Tanaka, Chie; Sugiura, Hideko; Goto, Hajime; Saraya, Takeshi; Kurai, Daisuke; Katono, Yasuhiro; Inose, Rika; Niki, Yoshihito; Takuma, Takahiro; Kudo, Makoto; Ehara, Shigeru; Sato, Yoshimi; Tsukada, Hiroki; Watabe, Nobuei; Honma, Yasuo; Mikamo, Hiroshige; Yamagishi, Yuka; Nakamura, Atsushi; Ohashi, Minoru; Seki, Masafumi; Hamaguchi, Shigeto; Toyokawa, Masahiro; Fujikawa, Yasunori; Mitsuno, Noriko; Ukimura, Akira; Miyara, Takayuki; Nakamura, Takahito; Mikasa, Keiichi; Kasahara, Kei; Ui, Koji; Fukuda, Saori; Nakamura, Akihiro; Morimura, Mika; Yamashita, Mikio; Takesue, Yoshio; Wada, Yasunao; Sugimoto, Keisuke; Kusano, Nobuchika; Nose, Motoko; Mihara, Eiichirou; Kuwabara, Masao; Doi, Masao; Watanabe, Yaeko; Tokuyasu, Hirokazu; Hino, Satoshi; Negayama, Kiyoshi; Mukae, Hiroshi; Kawanami, Toshinori; Ota, Toshiyuki; Fujita, Masaki; Honda, Junichi; Hiramatsu, Kazufumi; Aoki, Yosuke; Fukuoka, Mami; Magarifuchi, Hiroki; Nagasawa, Zenzo; Kaku, Norihito; Fujita, Jiro; Higa, Futoshi; Tateyama, Masao

    2017-09-01

    The nationwide surveillance on antimicrobial susceptibility of bacterial respiratory pathogens from the patients in Japan was conducted by Japanese Society of Chemotherapy, Japanese association for infectious diseases and Japanese society for Clinical Microbiology in 2012. The isolates were collected from clinical specimens obtained from well-diagnosed adult patients with respiratory tract infections during the period between January and December in 2012 by three societies. Antimicrobial susceptibility testing was conducted at the central reference laboratory according to the method recommended by Clinical Laboratory Standard Institutes. Susceptibility testing was evaluated in 1236 strains (232 Staphylococcus aureus, 225 Streptococcus pneumoniae, 16 Streptococcus pyogenes, 231 Haemophilus influenzae, 147 Moraxella catarrhalis, 167 Klebsiella pneumoniae and 218 Pseudomonas aeruginosa). Ratio of methicillin-resistant S. aureus was 51.3%, and those of penicillin-intermediate S. pneumoniae was 0.4%. Among H. influenzae, 5.6% of them were found to be β-lactamase-producing ampicillin-resistant strains, and 37.2% to be β-lactamase-non-producing ampicillin-resistant strains. Extended spectrum β-lactamase-producing K. pneumoniae and multi-drug resistant P. aeruginosa with metallo β-lactamase were 4.2% and 3.2%, respectively. Continuous national surveillance is important to determine the actual situation of the resistance shown by bacterial respiratory pathogens to antimicrobial agents. Copyright © 2017 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  19. 16 CFR Figure 3 to Part 1610 - Specimen Holder Supported in Specimen Rack

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Specimen Holder Supported in Specimen Rack 3 Figure 3 to Part 1610 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT... Holder Supported in Specimen Rack ER25MR08.002 ...

  20. A family-wide RT-PCR assay for detection of paramyxoviruses and application to a large-scale surveillance study.

    Directory of Open Access Journals (Sweden)

    Sander van Boheemen

    Full Text Available Family-wide molecular diagnostic assays are valuable tools for initial identification of viruses during outbreaks and to limit costs of surveillance studies. Recent discoveries of paramyxoviruses have called for such assay that is able to detect all known and unknown paramyxoviruses in one round of PCR amplification. We have developed a RT-PCR assay consisting of a single degenerate primer set, able to detect all members of the Paramyxoviridae family including all virus genera within the subfamilies Paramyxovirinae and Pneumovirinae. Primers anneal to domain III of the polymerase gene, with the 3' end of the reverse primer annealing to the conserved motif GDNQ, which is proposed to be the active site for nucleotide polymerization. The assay was fully optimized and was shown to indeed detect all available paramyxoviruses tested. Clinical specimens from hospitalized patients that tested positive for known paramyxoviruses in conventional assays were also detected with the novel family-wide test. A high-throughput fluorescence-based RT-PCR version of the assay was developed for screening large numbers of specimens. A large number of samples collected from wild birds was tested, resulting in the detection of avian paramyxoviruses type 1 in both barnacle and white-fronted geese, and type 8 in barnacle geese. Avian metapneumovirus type C was found for the first time in Europe in mallards, greylag geese and common gulls. The single round family-wide RT-PCR assay described here is a useful tool for the detection of known and unknown paramyxoviruses, and screening of large sample collections from humans and animals.

  1. Surveillance and Critical Theory

    Directory of Open Access Journals (Sweden)

    Christian Fuchs

    2015-09-01

    Full Text Available In this comment, the author reflects on surveillance from a critical theory approach, his involvement in surveillance research and projects, and the status of the study of surveillance. The comment ascertains a lack of critical thinking about surveillance, questions the existence of something called “surveillance studies” as opposed to a critical theory of society, and reflects on issues such as Edward Snowden’s revelations, and Foucault and Marx in the context of surveillance.

  2. Semantic-based surveillance video retrieval.

    Science.gov (United States)

    Hu, Weiming; Xie, Dan; Fu, Zhouyu; Zeng, Wenrong; Maybank, Steve

    2007-04-01

    Visual surveillance produces large amounts of video data. Effective indexing and retrieval from surveillance video databases are very important. Although there are many ways to represent the content of video clips in current video retrieval algorithms, there still exists a semantic gap between users and retrieval systems. Visual surveillance systems supply a platform for investigating semantic-based video retrieval. In this paper, a semantic-based video retrieval framework for visual surveillance is proposed. A cluster-based tracking algorithm is developed to acquire motion trajectories. The trajectories are then clustered hierarchically using the spatial and temporal information, to learn activity models. A hierarchical structure of semantic indexing and retrieval of object activities, where each individual activity automatically inherits all the semantic descriptions of the activity model to which it belongs, is proposed for accessing video clips and individual objects at the semantic level. The proposed retrieval framework supports various queries including queries by keywords, multiple object queries, and queries by sketch. For multiple object queries, succession and simultaneity restrictions, together with depth and breadth first orders, are considered. For sketch-based queries, a method for matching trajectories drawn by users to spatial trajectories is proposed. The effectiveness and efficiency of our framework are tested in a crowded traffic scene.

  3. Text Fixture for Double Cantilever Beam (DCB) Specimens Subjected to Uneven Bending Moments

    DEFF Research Database (Denmark)

    Svenninggaard, Jon; Andreasen, Jens; Bak, Brian

    Bending Moments as a function of the phase angle ranging from mode I to mode II loading including mixed modes in-between. The test fixture utilizes an existing tensile testing machine and can subject specimens to loads up to 350 Nm. The test fixture is compact in size and designed using standard aluminium...... profiles for the main structure. The load is transferred from the test machine to the specimen through a 2 mm Dyneema rope. The rope is routed over a set of rollers that are positioned according to the specified mode mixity and phase angle. The kinematics of the test fixture has been analysed extensively...... strength in layered materials the cohesive law and fracture strength must be known. Ideally the entire cohesive law is known in order to aid in the design of components and structures. In this work we present a novel test fixture which can be used to test DCB specimens that are subjected to pure Uneven...

  4. Performance of ARCHITECT HCV core antigen test with specimens from US plasma donors and injecting drug users.

    Science.gov (United States)

    Mixson-Hayden, Tonya; Dawson, George J; Teshale, Eyasu; Le, Thao; Cheng, Kevin; Drobeniuc, Jan; Ward, John; Kamili, Saleem

    2015-05-01

    Hepatitis C virus (HCV) core antigen is a serological marker of current HCV infection. The aim of this study was mainly to evaluate the performance characteristics of the ARCHITECT HCV core antigen assay with specimens from US plasma donors and injecting drug users. A total of 551 serum and plasma samples with known anti-HCV and HCV RNA status were tested for HCV core antigen using the Abbott ARCHITECT HCV core antigen test. HCV core antigen was detectable in 100% of US plasma donor samples collected during the pre-seroconversion phase of infection (anti-HCV negative/HCV RNA positive). Overall sensitivity of the HCV core antigen assay was 88.9-94.3% in samples collected after seroconversion. The correlation between HCV core antigen and HCV RNA titers was 0.959. HCV core antigen testing may be reliably used to identify current HCV infection. Published by Elsevier B.V.

  5. Sequencing historical specimens: successful preparation of small specimens with low amounts of degraded DNA.

    Science.gov (United States)

    Sproul, John S; Maddison, David R

    2017-11-01

    Despite advances that allow DNA sequencing of old museum specimens, sequencing small-bodied, historical specimens can be challenging and unreliable as many contain only small amounts of fragmented DNA. Dependable methods to sequence such specimens are especially critical if the specimens are unique. We attempt to sequence small-bodied (3-6 mm) historical specimens (including nomenclatural types) of beetles that have been housed, dried, in museums for 58-159 years, and for which few or no suitable replacement specimens exist. To better understand ideal approaches of sample preparation and produce preparation guidelines, we compared different library preparation protocols using low amounts of input DNA (1-10 ng). We also explored low-cost optimizations designed to improve library preparation efficiency and sequencing success of historical specimens with minimal DNA, such as enzymatic repair of DNA. We report successful sample preparation and sequencing for all historical specimens despite our low-input DNA approach. We provide a list of guidelines related to DNA repair, bead handling, reducing adapter dimers and library amplification. We present these guidelines to facilitate more economical use of valuable DNA and enable more consistent results in projects that aim to sequence challenging, irreplaceable historical specimens. © 2017 John Wiley & Sons Ltd.

  6. Comparison of embrittlement trend curves to high fluence surveillance results

    International Nuclear Information System (INIS)

    Bogaert, A.S.; Gerard, R.; Chaouadi, R.

    2011-01-01

    In the regulatory justification of the integrity of the reactor pressure vessels (RPV) for long term operation, use is made of predictive formulas (also called trend curves) to evaluate the RPV embrittlement (expressed in terms of RTNDT shifts) in function of fluence, chemical composition and in some cases temperature, neutron flux or product form. It has been shown recently that some of the existing or proposed trend curves tend to underpredict high dose embrittlement. Due to the scarcity of representative surveillance data at high dose, some test reactor results were used in these evaluations and raise the issue of representativeness of the accelerated test reactor irradiations (dose rate effects). In Belgium the surveillance capsules withdrawal schedule was modified in the nineties in order to obtain results corresponding to 60 years of operation or more with the initial surveillance program. Some of these results are already available and offer a good opportunity to test the validity of the predictive formulas at high dose. In addition, advanced surveillance methods are used in Belgium like the Master Curve, increased tensile tests, and microstructural investigations. These techniques made it possible to show the conservatism of the regulatory approach and to demonstrate increased margins, especially for the first generation units. In this paper the surveillance results are compared to different predictive formulas, as well as to an engineering hardening model developed at SCK.CEN. Generally accepted property-to-property correlations are critically revisited. Conclusions are made on the reliability and applicability of the embrittlement trend curves. (authors)

  7. Influence of specimen size on the creep of rock salt

    International Nuclear Information System (INIS)

    Senseny, P.E.

    1982-01-01

    Triaxial compression creep data for Avery Island dome salt are analyzed to determine the influence of specimen size on creep deformation. Laboratory experiments were performed on 50- and 100-mm-diameter specimens in the temperature range from 25 to 200 0 C and the axial stress difference range from 2.5 to 31.0 MPa. The strain-vs-time data from each test are divided into transient and steady-state components. Results of statistical analysis of these data show that transient creep of the small specimens is a stronger function of stress, temperature, and time than is transient creep of the larger specimens. Analysis of the steady-state data show no size effect, however. 14 references, 7 figures, 3 tables

  8. The effect of residual stresses induced by prestraining on fatigue life of notched specimens

    Science.gov (United States)

    Sadeler, R.; Ozel, A.; Kaymaz, I.; Totik, Y.

    2005-06-01

    The effect of tensile prestraining-induced residual stress on the fatigue life of notched steel parts was investigated. The study was performed on AISI 4140 steel. Rotating bending fatigue tests were carried out on semicircular notched specimens with different notch radii in the as-quenched and tempered conditions. Metallography of the specimens was performed by means of light optical microscopy. The finite-element method was used to evaluate the residual stress distribution near the notch region. Fatigue tests revealed fatigue life improvement for notched specimens, which changes depending on the notch radii and applied stress. Scanning electron microscopy was used to examine the fracture surfaces of the specimens.

  9. Ideology, Critique and Surveillance

    Directory of Open Access Journals (Sweden)

    Heidi Herzogenrath-Amelung

    2013-11-01

    Full Text Available The 2013 revelations concerning global surveillance programmes demonstrate in unprecedented clarity the need for Critical Theory of information and communication technologies (ICTs to address the mechanisms and implications of increasingly global, ubiquitous surveillance. This is all the more urgent because of the dominance of the “surveillance ideology” (the promise of security through surveillance that supports the political economy of surveillance. This paper asks which theoretical arguments and concepts can be useful for philosophically grounding a critique of this surveillance ideology. It begins by examining how the surveillance ideology works through language and introduces the concept of the ‘ideological packaging’ of ICTs to show how rhetoric surrounding the implementation of surveillance technologies reinforces the surveillance ideology. It then raises the problem of how ideology-critique can work if it relies on language itself and argues that Martin Heidegger’s philosophy can make a useful contribution to existing critical approaches to language.

  10. A niching genetic algorithm applied to a nuclear power plant auxiliary feedwater system surveillance tests policy optimization

    International Nuclear Information System (INIS)

    Sacco, W.F.; Lapa, Celso M.F.; Pereira, C.M.N.A.; Oliveira, C.R.E. de

    2006-01-01

    This article extends previous efforts on genetic algorithms (GAs) applied to a nuclear power plant (NPP) auxiliary feedwater system (AFWS) surveillance tests policy optimization. We introduce the application of a niching genetic algorithm (NGA) to this problem and compare its performance to previous results. The NGA maintains a populational diversity during the search process, thus promoting a greater exploration of the search space. The optimization problem consists in maximizing the system's average availability for a given period of time, considering realistic features such as: (i) aging effects on standby components during the tests; (ii) revealing failures in the tests implies on corrective maintenance, increasing outage times; (iii) components have distinct test parameters (outage time, aging factors, etc.) and (iv) tests are not necessarily periodic. We find that the NGA performs better than the conventional GA and the island GA due to a greater exploration of the search space

  11. A determination of the benefits of annealing irradiated pressure vessel weldments

    International Nuclear Information System (INIS)

    Lott, R.G.; Mager, T.R.

    1988-01-01

    The long-term benefit of annealing an irradiated reactor pressure vessel steel may be described in terms of a benefit factor, B. The benefit factor compares the mechanical properties of an annealed and reirradiated specimen with an equivalent specimen having no intermediate anneal. The benefit factor was determined using a series of microhardness specimens prepared from nuclear pressure vessel surveillance program materials. These specimens were annealed and then reirradiated in a test reactor. There was an obvious long-term benefit in the specimens annealed at 450 0 C. The long-term benefit was less obvious at 400 0 C and no significant benefit was noted at 350 0 C. The benefit factor may also be used as the basis of a surveillance program for an annealed pressure vessel. A strategy for such a surveillance program is described. (author)

  12. Results of charpy V-notch impact testing of structural steel specimens irradiated at ∼30 degrees C to 1 x 1016 neutrons/cm2 in a commercial reactor cavity

    International Nuclear Information System (INIS)

    Iskander, S.K.; Stoller, R.E.

    1997-04-01

    A capsule containing Charpy V-notch (CVN) and mini-tensile specimens was irradiated at ∼ 30 degrees C (∼ 85 degrees F) in the cavity of a commercial nuclear power plant to a fluence of 1 x 10 16 neutrons/cm 2 (> 1MeV). The capsule included six CVN impact specimens of archival High Flux Isotope Reactor A212 grade B ferritic steel and five CVN impact specimens of a well-studied A36 structural steel. This irradiation was part of the ongoing study of neutron-induced damage effects at the low temperature and flux experienced by reactor supports. The plant operators shut down the plant before the planned exposure was reached. The exposure of these specimens produced no significant irradiation-induced embrittlement. Of interest were the data on unirradiated specimens in the L-T orientation machined from a single plate of A36 structural steel, which is the same specification for the structural steel used in some reactor supports. The average CVN energy of five unirradiated specimens obtained from one region of the plate and tested at room temperature was ∼ 99 J, while the energy of 11 unirradiated specimens from other locations of the same plate was 45 J, a difference of ∼ 220%. The CVN impact energies for all 18 specimens ranged from a low of 32 J to a high of 111 J. Moreover, it appears that the University of Kansas CVN impact energy data of the unirradiated specimens at the 100-J level are shifted toward higher temperatures by about 20 K. The results were an example of the extent of scatter possible in CVN impact testing. Generic values for the CVN impact energy of A36 should be used with caution in critical applications

  13. Prevalence of syphilis infection in different tiers of female sex workers in China: implications for surveillance and interventions

    Directory of Open Access Journals (Sweden)

    Chen Xiang-Sheng

    2012-04-01

    Full Text Available Abstract Background Syphilis has made a dramatic resurgence in China during the past two decades and become the third most prevalent notifiable infectious disease in China. Female sex workers (FSWs have become one of key populations for the epidemic. In order to investigate syphilis infection among different tiers of FSWs, a cross-sectional study was conducted in 8 sites in China. Methods Serum specimens (n = 7,118 were collected to test for syphilis and questionnaire interviews were conducted to obtain socio-demographic and behavioral information among FSWs recruited from different types of venues. FSWs were categorized into three tiers (high-, middle- and low-tier FSWs based on the venues where they solicited clients. Serum specimens were screened with enzyme-linked immunosorbent assay (ELISA for treponemal antibody followed by confirmation with non-treponemal toluidine red unheated serum test (TRUST for positive ELISA specimens to determine syphilis infection. A logistic regression model was used to determine factors associated with syphilis infection. Results Overall syphilis prevalence was 5.0% (95%CI, 4.5-5.5%. Low-tier FSWs had the highest prevalence (9.7%; 95%CI, 8.3-11.1%, followed by middle-tier (4.3%; 95%CI, 3.6-5.0%, P P Conclusions This multi-site survey showed a high prevalence of syphilis infection among FSWs and substantial disparities in syphilis prevalence by the tier of FSWs. The difference in syphilis prevalence is substantial between different tiers of FSWs, with the highest rate among low-tier FSWs. Thus, current surveillance and intervention activities, which have low coverage in low-tier FSWs in China, should be further examined.

  14. Epidemiological Concepts Regarding Disease Monitoring and Surveillance

    Directory of Open Access Journals (Sweden)

    Christensen Jette

    2001-03-01

    Full Text Available Definitions of epidemiological concepts regarding disease monitoring and surveillance can be found in textbooks on veterinary epidemiology. This paper gives a review of how the concepts: monitoring, surveillance, and disease control strategies are defined. Monitoring and surveillance systems (MO&SS involve measurements of disease occurrence, and the design of the monitoring determines which types of disease occurrence measures can be applied. However, the knowledge of the performance of diagnostic tests (sensitivity and specificity is essential to estimate the true occurrence of the disease. The terms, disease control programme (DCP or disease eradication programme (DEP, are defined, and the steps of DCP/DEP are described to illustrate that they are a process rather than a static MO&SS.

  15. Statistical analysis on the fluence factor of surveillance test data of Korean nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Gyeong Geun; Kim, Min Chul; Yoon, Ji Hyun; Lee, Bong Sang; Lim, Sang Yeob; Kwon, Jun Hyun [Nuclear Materials Safety Research Division, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-06-15

    The transition temperature shift (TTS) of the reactor pressure vessel materials is an important factor that determines the lifetime of a nuclear power plant. The prediction of the TTS at the end of a plant’s lifespan is calculated based on the equation of Regulatory Guide 1.99 revision 2 (RG1.99/2) from the US. The fluence factor in the equation was expressed as a power function, and the exponent value was determined by the early surveillance data in the US. Recently, an advanced approach to estimate the TTS was proposed in various countries for nuclear power plants, and Korea is considering the development of a new TTS model. In this study, the TTS trend of the Korean surveillance test results was analyzed using a nonlinear regression model and a mixed-effect model based on the power function. The nonlinear regression model yielded a similar exponent as the power function in the fluence compared with RG1.99/2. The mixed-effect model had a higher value of the exponent and showed superior goodness of fit compared with the nonlinear regression model. Compared with RG1.99/2 and RG1.99/3, the mixed-effect model provided a more accurate prediction of the TTS.

  16. The effect of specimen and flaw dimensions on fracture toughness

    International Nuclear Information System (INIS)

    Nevalainen, M.J.

    1997-06-01

    The effect of the specimen size and geometry on fracture toughness has been investigated both by experimental tests and computational analyses. The methods for constraint description, namely T-stress, Q-parameter and Small-Scale Yielding Correction (SSYC) have been compared and applied for various geometries. A statistical treatment for the specimen thickness effect on cleavage fracture toughness has been investigated. Elliptical surface cracks were compared with straight-thickness cracks and a method for crack shape correction was presented. Based on the results, the differences in apparent fracture toughness values obtained from various specimen configurations can be better understood and taken into account

  17. Who is Surveilling Whom?

    DEFF Research Database (Denmark)

    Mortensen, Mette

    2014-01-01

    This article concerns the particular form of counter-surveillance termed “sousveillance”, which aims to turn surveillance at the institutions responsible for surveillance. Drawing on the theoretical perspectives “mediatization” and “aerial surveillance,” the article studies WikiLeaks’ publication...

  18. Cost-effectiveness of lobectomy versus genetic testing (Afirma®) for indeterminate thyroid nodules: Considering the costs of surveillance.

    Science.gov (United States)

    Balentine, Courtney J; Vanness, David J; Schneider, David F

    2018-01-01

    We evaluated whether diagnostic thyroidectomy for indeterminate thyroid nodules would be more cost-effective than genetic testing after including the costs of long-term surveillance. We used a Markov decision model to estimate the cost-effectiveness of thyroid lobectomy versus genetic testing (Afirma®) for evaluation of indeterminate (Bethesda 3-4) thyroid nodules. The base case was a 40-year-old woman with a 1-cm indeterminate nodule. Probabilities and estimates of utilities were obtained from the literature. Cost estimates were based on Medicare reimbursements with a 3% discount rate for costs and quality-adjusted life-years. During a 5-year period after the diagnosis of indeterminate thyroid nodules, lobectomy was less costly and more effective than Afirma® (lobectomy: $6,100; 4.50 quality-adjusted life- years vs Afirma®: $9,400; 4.47 quality-adjusted life-years). Only in 253 of 10,000 simulations (2.5%) did Afirma® show a net benefit at a cost-effectiveness threshold of $100,000 per quality- adjusted life-years. There was only a 0.3% probability of Afirma® being cost saving and a 14.9% probability of improving quality-adjusted life-years. Our base case estimate suggests that diagnostic lobectomy dominates genetic testing as a strategy for ruling out malignancy of indeterminate thyroid nodules. These results, however, were highly sensitive to estimates of utilities after lobectomy and living under surveillance after Afirma®. Published by Elsevier Inc.

  19. [Susceptibility surveillance of clinical isolates to fluoroquinolone antimicrobial agents from 2003 to 2008: post-marketing study of prulifloxacin].

    Science.gov (United States)

    Kawai, Shin; Yoshida, Atsushi; Okazaki, Mitsuhiro; Tsujihara, Yoshito; Inuzuka, Kazuhisa; Takeuchi, Kazuhide; Yamashita, Naoko; Onodera, Makoto; Hiraishi, Toru; Ida, Takashi; Maebashi, Kazunori

    2010-06-01

    Yearly changes in the susceptibility of clinical isolates to ulifloxacin (UFX) and other fluoroquinolones were examined through surveys over 3 periods. In the first survey, 534 strains derived from 19 species were collected from clinical specimens during 6 months from December 2003 to May 2004. In the same way, 805 strains were collected from December 2005 to May 2006 in the second survey, and 863 strains were from December 2007 to May 2008 in the third survey. Over these 3 study periods, the susceptibilities of fluoroquinolones against methicillin-susceptible Staphylococcus aureus and Escherichia coli were decreased. The isolation frequency of levofloxacin-nonsusceptible strain was increased from 0% to 11.8% and from 14.6% to 20.8%, respectively. MIC90s of UFX against these pathogens were also increased, but its MIC90 for E. coli was 2 to 4 times lower than that of levofloxacin. On the other hand, the susceptibility of strains of Klebsiella pneumoniae to UFX was increased. Among the fluoroquinolones tested, UFX showed the most potent activity against Pseudomonas aeruginosa, and no changes in the MIC90s occurred during the surveillance. Although one strain of Streptococcus pneumoniae isolated in the third study period showed levofloxacin-resistance (MIC, 8 microg/mL), there were nearly no changes in the MIC90s of any agents tested including UFX against S. pneumoniae during the surveillance. As for other bacterial species, a tendency to increase in resistance to UFX was not observed. The activity of UFX against Salmonella spp. and Shigella spp. was superior/equal to those of fluoroquinolones tested.

  20. Experimental Study On Fracture Property Of Double Cantilever Beam Specimen With Aluminum Foam

    Directory of Open Access Journals (Sweden)

    Kim Y.C.

    2015-06-01

    Full Text Available This study aims to investigate double cantilever beam specimen with aluminum foam bonded by spray adhesive to investigate the fracture strength of the adhesive joint experimentally. The fracture energy at opening mode is calculated by the formulae of British Engineering Standard (BS 7991 and International Standard (ISO 11343. For the static experiment, four types of specimens with the heights (h of 25 mm, 30 mm, 35 mm and 40 mm are manufactured and the experimental results are compared with each other. As the height becomes greater, the fracture energy becomes higher. After the length of crack reaches 150 mm, the fracture energy of the specimen (h=35 mm is greater than that of the specimen (h=40 mm. Fatigue test is also performed with DCB test specimen. As the height decreases, the fracture energy becomes higher. By the result obtained from this study, aluminum foam with adhesive joint can be applied to actual composite structure and its fracture property can possibly be anticipated.