WorldWideScience

Sample records for surveillance system stations

  1. Experience and development of on-line BWR surveillance system at Onagawa nuclear power station unit-1

    International Nuclear Information System (INIS)

    Kishi, A.; Chiba, K.; Kato, K.; Ebata, S.; Ando, Y.; Sakamoto, H.

    1986-01-01

    ONAGAWA nuclear power station Unit-1 (Tohoku Electric Power Co.) is a BWR-4 nuclear power station of 524 MW electric power which started commercial operation in June 1984. To attain high reliability and applicability for ONAGAWA-1, Tohoku Electric Power Co. and Toshiba started a Research and Development project on plant surveillance and diagnosis from April 1982. Main purposes of this project are to: (1) Develop an on-line surveillance system and acquire its operating experience at a commercial BWR, (2) Assist in plant operation and maintenance by data acquisition and analysis, (3) Develop a new technique for plant surveillance and diagnosis. An outline of the project, operating experience gained from the on-line surveillance system and an introduction to new diagnosis techniques are reported in this paper. (author)

  2. Semi-automated reviewing station for IAEA optical surveillance data

    International Nuclear Information System (INIS)

    Darnell, R.A.; Sonnier, C.S.

    1987-01-01

    A study is underway on the use of computer vision technology to assist in visual inspection of optical surveillance data. The IAEA currently uses optical surveillance as one of its principle Containment and Surveillance (C/S) measures. The review process is a very time-consuming and tedious task, due to the large amount of optical surveillance data to be reviewed. For some time, the IAEA has identified as one of its principle needs an automated optical surveillance data reviewing station that assists the reviewer in identifying activities of safeguards interest, such as the movement of a very large spent fuel cask. The present development reviewing station consists of commercially available digital image processing hardware controlled by a personal computer. The areas under study include change detection, target discrimination, tracking, and classification. Several algorithms are being evaluated in each of these areas using recorded video tape of safeguards relevant scenes. The computer vision techniques and current status of the studies are discussed

  3. Reevaluation of air surveillance station siting

    International Nuclear Information System (INIS)

    Abbott, K.; Jannik, T.

    2016-01-01

    DOE Technical Standard HDBK-1216-2015 (DOE 2015) recommends evaluating air-monitoring station placement using the analytical method developed by Waite. The technique utilizes wind rose and population distribution data in order to determine a weighting factor for each directional sector surrounding a nuclear facility. Based on the available resources (number of stations) and a scaling factor, this weighting factor is used to determine the number of stations recommended to be placed in each sector considered. An assessment utilizing this method was performed in 2003 to evaluate the effectiveness of the existing SRS air-monitoring program. The resulting recommended distribution of air-monitoring stations was then compared to that of the existing site perimeter surveillance program. The assessment demonstrated that the distribution of air-monitoring stations at the time generally agreed with the results obtained using the Waite method; however, at the time new stations were established in Barnwell and in Williston in order to meet requirements of DOE guidance document EH-0173T.

  4. Reevaluation of air surveillance station siting

    Energy Technology Data Exchange (ETDEWEB)

    Abbott, K. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jannik, T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-07-06

    DOE Technical Standard HDBK-1216-2015 (DOE 2015) recommends evaluating air-monitoring station placement using the analytical method developed by Waite. The technique utilizes wind rose and population distribution data in order to determine a weighting factor for each directional sector surrounding a nuclear facility. Based on the available resources (number of stations) and a scaling factor, this weighting factor is used to determine the number of stations recommended to be placed in each sector considered. An assessment utilizing this method was performed in 2003 to evaluate the effectiveness of the existing SRS air-monitoring program. The resulting recommended distribution of air-monitoring stations was then compared to that of the existing site perimeter surveillance program. The assessment demonstrated that the distribution of air-monitoring stations at the time generally agreed with the results obtained using the Waite method; however, at the time new stations were established in Barnwell and in Williston in order to meet requirements of DOE guidance document EH-0173T.

  5. Intelligent video surveillance systems and technology

    CERN Document Server

    Ma, Yunqian

    2009-01-01

    From the streets of London to subway stations in New York City, hundreds of thousands of surveillance cameras ubiquitously collect hundreds of thousands of videos, often running 24/7. How can such vast volumes of video data be stored, analyzed, indexed, and searched? How can advanced video analysis and systems autonomously recognize people and detect targeted activities real-time? Collating and presenting the latest information Intelligent Video Surveillance: Systems and Technology explores these issues, from fundamentals principle to algorithmic design and system implementation.An Integrated

  6. Surveyor mobile surveillance system for hazardous environments

    International Nuclear Information System (INIS)

    Silverman, E.B.; Simmons, R.K.; Kniazewycz, B.G.; Darvish, A.R.; Irving, T.L.

    1987-01-01

    A successful program was recently conducted to test and evaluate a commercial-ready, wireless, remotely operated surveillance system for use in nuclear power plants. This evaluation of the Surveyor mobile surveillance system took place at Niagara Mohawk Power Corporation's Nine Mile Point Nuclear Power Station. The remotely operated vehicle measures radiation, temperature and relative humidity and provides optical inspection capability. The vehicle is readily maneuvered in 36-inch wide passageways and labyrinth entries and can climb stairs, negotiating 180-degree turns on stair landings. The system consists of a supervisory control station and a rugged, remotely-operated, battery-powered vehicle. The surveyor system is specifically designed to decrease personnel radiation exposure by supplementing the functions of an auxiliary operator or wealth physics technician to perform periodic component inspections inside particular areas within a nuclear power plant

  7. Modular integrated video system (MIVS) review station

    International Nuclear Information System (INIS)

    Garcia, M.L.

    1988-01-01

    An unattended video surveillance unit, the Modular Integrated Video System (MIVS), has been developed by Sandia National Laboratories for International Safeguards use. An important support element of this system is a semi-automatic Review Station. Four component modules, including an 8 mm video tape recorder, a 4-inch video monitor, a power supply and control electronics utilizing a liquid crystal display (LCD) are mounted in a suitcase for probability. The unit communicates through the interactive, menu-driven LCD and may be operated on facility power through the world. During surveillance, the MIVS records video information at specified time intervals, while also inserting consecutive scene numbers and tamper event information. Using either of two available modes of operation, the Review Station reads the inserted information and counts the number of missed scenes and/or tamper events encountered on the tapes, and reports this to the user on the LCD. At the end of a review session, the system will summarize the results of the review, stop the recorder, and advise the user of the completion of the review. In addition, the Review Station will check for any video loss on the tape

  8. Cost analysis of various low pathogenic avian influenza surveillance systems in the Dutch egg layer sector.

    Directory of Open Access Journals (Sweden)

    Niels Rutten

    Full Text Available BACKGROUND: As low pathogenic avian influenza viruses can mutate into high pathogenic viruses the Dutch poultry sector implemented a surveillance system for low pathogenic avian influenza (LPAI based on blood samples. It has been suggested that egg yolk samples could be sampled instead of blood samples to survey egg layer farms. To support future decision making about AI surveillance economic criteria are important. Therefore a cost analysis is performed on systems that use either blood or eggs as sampled material. METHODOLOGY/PRINCIPAL FINDINGS: The effectiveness of surveillance using egg or blood samples was evaluated using scenario tree models. Then an economic model was developed that calculates the total costs for eight surveillance systems that have equal effectiveness. The model considers costs for sampling, sample preparation, sample transport, testing, communication of test results and for the confirmation test on false positive results. The surveillance systems varied in sampled material (eggs or blood, sampling location (farm or packing station and location of sample preparation (laboratory or packing station. It is shown that a hypothetical system in which eggs are sampled at the packing station and samples prepared in a laboratory had the lowest total costs (i.e. € 273,393 a year. Compared to this a hypothetical system in which eggs are sampled at the farm and samples prepared at a laboratory, and the currently implemented system in which blood is sampled at the farm and samples prepared at a laboratory have 6% and 39% higher costs respectively. CONCLUSIONS/SIGNIFICANCE: This study shows that surveillance for avian influenza on egg yolk samples can be done at lower costs than surveillance based on blood samples. The model can be used in future comparison of surveillance systems for different pathogens and hazards.

  9. Present status of metrology of electro-optical surveillance systems

    Science.gov (United States)

    Chrzanowski, K.

    2017-10-01

    There has been a significant progress in equipment for testing electro-optical surveillance systems over the last decade. Modern test systems are increasingly computerized, employ advanced image processing and offer software support in measurement process. However, one great challenge, in form of relative low accuracy, still remains not solved. It is quite common that different test stations, when testing the same device, produce different results. It can even happen that two testing teams, while working on the same test station, with the same tested device, produce different results. Rapid growth of electro-optical technology, poor standardization, limited metrology infrastructure, subjective nature of some measurements, fundamental limitations from laws of physics, tendering rules and advances in artificial intelligence are major factors responsible for such situation. Regardless, next decade should bring significant improvements, since improvement in measurement accuracy is needed to sustain fast growth of electro-optical surveillance technology.

  10. An Interfacing System for Radiation Surveillance Using a Radio Communication Network

    International Nuclear Information System (INIS)

    Arunsiri, T.; Punnachaiya, S.; Pattarasumun, A.

    1998-01-01

    The development of an interfacing system for environmental radiation surveillance using radio communication network is aimed to improve a way by which environmental radiation measurement is transmitted and reported from the regional area monitoring station network. This also includes an automatic warning of beacon status via the radio link network to the center of environmental radiation control when an abnormal radiation level is detected. The interfacing system was developed by simulating the EGAT radio link network, the NT 2612, and can be separated into two parts. The first part was for a mobile station which can manage the output data from the radiation measurement system in the standard form of RS-232, IEEE-488, BCD and analog signal. This was accomplished by modulating the signal in selected baud rates ranging from 150 to 9600 bps using an economical radio packet capable of identifying and recalling the station code number. The other part is the linking system between the output data and the microcomputer equipped with a software to manage and evaluate the data from 10 surveillance stations for convenient handing of data output, statistical analysis and transmitting warning signal. Data transmission was tested using a baud rate of 1200 bps and was found to contain no detectable error when digital signal was transmitted while analog signal transmission resulted in deviations of less than ± 0.003%. The development of this radio link system provides a future trend for the environmental radiation monitoring network for countries with nuclear power plants or neighboring countries needed to continuously monitor for any abnormal radiation level in the environment. In case that the radiation surveillance system detects a high level of radiation, a warning signal will be transmitted and appropriate actions may be immediately exercised to control impacts of radiation on environment and living things according to international guidelines

  11. Experience in surveillance of the prestress of concrete reactor vessels in Wylfa nuclear power station

    International Nuclear Information System (INIS)

    Dawson, P.; Paton, A.A.; Walsh, S.R.

    1989-01-01

    This paper describes experience gained in the in-service surveillance of the prestressing system for the prestressed concrete reactor vessels (PCRVs) at Wylfa nuclear power station. The paper gives details of results for the prestressing system obtained from the statutory in-service inspection program of the PCRVs. The program includes a detailed examination of a selection of prestressing tendon anchorages, anchorage load checks using a lift-off technique on a one percent sample of tendons and corrosion inspection of samples of prestressing strand and determination of their mechanical properties. The results obtained from the above in-service inspections have shown that the prestressing system continues to function within its design limits

  12. Improvements for optical surveillance systems in international safeguards

    International Nuclear Information System (INIS)

    Richter, B.; Stein, G.; Neumann, G.; Gaertner, K.J.; Whichello, J.N.

    1988-01-01

    Within the next few years, a transition from film camera systems to video surveillance systems will take place in international safeguards. In order to maintain the indispensable requirements of reliability and authentication, development and tests continued under the Federal Republic of Germany Support Programme of video components for IAEA safeguards applications. The prototype of a tamper resistant TV-link was developed under Task D.12/4/. A field test of the TV-link is in preparation using a production model suitable for multiplexed TV applications. The test will utilize an Agency owned, multiplexed TV system. An evaluation of the tamper resistant TV-link is given. After a successful field trial of the prototype Solid State Video Memory (SSVM-516) under task D.14 a production model has been developed under Task D.17. Several operating modes are envisaged, depending on whether it will be used in an on-site video surveillance system or in a video review station. The concept and technical features, including an explanation of the function of the video memory, are discussed

  13. Quality surveillance at Duke Power operating nuclear stations

    International Nuclear Information System (INIS)

    Bradley, W.H.

    1985-01-01

    The Duke Power quality assurance (QA) program originally had three levels of QA audits that reported results to different levels of management and in different time frames. It soon became obvious that although problems were being identified, considerable confusion was being created by reporting them to different levels. Additionally, it was recognized that all audits were dealing in history: events that had already occurred and therefore could not be averted. What was needed was a problem identification system focused on current activities. The Duke quality surveillance program was created by dropping the first level of audits and replacing it with an on-the-scene review system to identify current problems. The quality surveillance program is a success and will be even more so after surveillance personnel acquire additional technical expertise. To that end, a training program has been initiated that will stop just short of operator licensing in the operations area and will also include other areas such as health physics and chemistry

  14. Privacy Implications of Surveillance Systems

    DEFF Research Database (Denmark)

    Thommesen, Jacob; Andersen, Henning Boje

    2009-01-01

    This paper presents a model for assessing the privacy „cost‟ of a surveillance system. Surveillance systems collect and provide personal information or observations of people by means of surveillance technologies such as databases, video or location tracking. Such systems can be designed for vari......This paper presents a model for assessing the privacy „cost‟ of a surveillance system. Surveillance systems collect and provide personal information or observations of people by means of surveillance technologies such as databases, video or location tracking. Such systems can be designed...... for various purposes, even as a service for those being observed, but in any case they will to some degree invade their privacy. The model provided here can indicate how invasive any particular system may be – and be used to compare the invasiveness of different systems. Applying a functional approach......, the model is established by first considering the social function of privacy in everyday life, which in turn lets us determine which different domains will be considered as private, and finally identify the different types of privacy invasion. This underlying model (function – domain – invasion) then serves...

  15. Verification station for Sandia/Rockwell Plutonium Protection system

    International Nuclear Information System (INIS)

    Nicholson, N.; Hastings, R.D.; Henry, C.N.; Millegan, D.R.

    1979-04-01

    A verification station has been designed to confirm the presence of plutonium within a container module. These container modules [about 13 cm (5 in.) in diameter and 23 cm (9 in.) high] hold sealed food-pack cans containing either plutonium oxide or metal and were designed by Sandia Laboratories to provide security and continuous surveillance and safety. After the plutonium is placed in the container module, it is closed with a solder seal. The verification station discussed here is used to confirm the presence of plutonium in the container module before it is placed in a carousel-type storage array inside the plutonium storage vault. This measurement represents the only technique that uses nuclear detectors in the plutonium protection system

  16. Environmental health surveillance system; Kankyo hoken surveillance system

    Energy Technology Data Exchange (ETDEWEB)

    Ono, M. [National Inst. for Environmental Studies, Tsukuba (Japan)

    1998-02-01

    The Central Environmental Pollution Prevention Council pointed out the necessity to establish an environmental health surveillance system (hereinafter referred to as System) in its report `on the first type district specified by the Environmental Pollution Caused Health Damages Compensation Act,` issued in 1986. A study team, established in Environment Agency, has been discussing to establish System since 1986. This paper outlines System, and some of the pilot surveillance results. It is not aimed at elucidation of the cause-effect relationships between health and air pollution but at discovery of problems, in which the above relationships in a district population are monitored periodically and continuously from long-term and prospective viewpoints, in order to help take necessary measures in the early stage. System is now collecting the data of the chronic obstructive lung diseases on a nation-wide scale through health examinations of 3-year-old and preschool children and daily air pollution monitoring. 6 refs., 3 figs., 1 tab.

  17. Remote container monitoring and surveillance systems

    International Nuclear Information System (INIS)

    Resnik, W.M.; Kadner, S.P.

    1995-01-01

    Aquila Technologies Group is developing a monitoring and surveillance system to monitor containers of nuclear materials. The system will both visually and physically monitor the containers. The system is based on the combination of Aquila's Gemini All-Digital Surveillance System and on Aquila's AssetLAN trademark asset tracking technology. This paper discusses the Gemini Digital Surveillance system as well as AssetLAN technology. The Gemini architecture with emphasis on anti-tamper security features is also described. The importance of all-digital surveillance versus other surveillance methods is also discussed. AssetLAN trademark technology is described, emphasizing the ability to continually track containers (as assets) by location utilizing touch memory technology. Touch memory technology provides unique container identification, as well as the ability to store and retrieve digital information on the container. This information may relate to container maintenance, inspection schedules, and other information. Finally, this paper describes the combination of the Gemini system with AssetLAN technology, yielding a self contained, container monitoring and area/container surveillance system. Secure container fixture design considerations are discussed. Basic surveillance review functions are also discussed

  18. Laser surveillance system (LASSY)

    International Nuclear Information System (INIS)

    Boeck, H.

    1991-09-01

    Laser Surveillance System (LASSY) is a beam of laser light which scans a plane above the water or under-water in a spent-fuel pond. The system can detect different objects and estimates its coordinates and distance as well. LASSY can operate in stand-alone configuration or in combination with a video surveillance to trigger signal to a videorecorder. The recorded information on LASSY computer's disk comprises date, time, start and stop angle of detected alarm, the size of the disturbance indicated in number of deviated points and some other information. The information given by the laser system cannot be fully substituted by TV camera pictures since the scanning beam creates a horizontal surveillance plan. The engineered prototype laser system long-term field test has been carried out in Soluggia (Italy) and has shown its feasibility and reliability under the conditions of real spent fuel storage pond. The verification of the alarm table on the LASSY computer with the recorded video pictures of TV surveillance system confirmed that all alarm situations have been detected. 5 refs

  19. Future Expansion of the Lightning Surveillance System at the Kennedy Space Center and the Cape Canaveral Air Force Station, Florida, USA

    Science.gov (United States)

    Mata, C. T.; Wilson, J. G.

    2012-01-01

    The NASA Kennedy Space Center (KSC) and the Air Force Eastern Range (ER) use data from two cloud-to-ground (CG) lightning detection networks, the Cloud-to-Ground Lightning Surveillance System (CGLSS) and the U.S. National Lightning Detection Network (NLDN), and a volumetric mapping array, the lightning detection and ranging II (LDAR II) system: These systems are used to monitor and characterize lightning that is potentially hazardous to launch or ground operations and hardware. These systems are not perfect and both have documented missed lightning events when compared to the existing lightning surveillance system at Launch Complex 39B (LC39B). Because of this finding it is NASA's plan to install a lightning surveillance system around each of the active launch pads sharing site locations and triggering capabilities when possible. This paper shows how the existing lightning surveillance system at LC39B has performed in 2011 as well as the plan for the expansion around all active pads.

  20. System specification for the integrated monitoring and surveillance system

    International Nuclear Information System (INIS)

    1997-09-01

    This System Specification establishes the requirements for the Plutonium Focus Area (PFA) Integrated Monitoring and Surveillance System (IMSS). In this document, ''Integrated Monitoring and Surveillance System'' is used to describe the concept of integrated sensors, computers, personnel, and systems that perform the functions of sensing conditions, acquiring data, monitoring environmental safety and health, controlling and accounting for materials, monitoring material stability, monitoring container integrity, transferring data, and analyzing, reporting, and storing data. This concept encompasses systems (e.g. sensors, personnel, databases, etc.) that are already in place at the sites but may require modifications or additions to meet all identified surveillance requirements. The purpose of this System Specification is to provide Department of Energy (DOE) sites that store plutonium materials with a consolidation of all known requirements for the storage and surveillance of 3013 packages of stabilized plutonium metals and oxides. This compilation may be used (1) as a baseline for surveillance system design specifications where 3013 packages of stabilized plutonium metals and oxides will be stored and monitored; (2) as a checklist for evaluating existing surveillance systems to ensure that all requirements are met for the storage and surveillance of 3013 packages of stabilized plutonium metals and oxides; and (3) as a baseline for preparing procurement specifications tailored for site specific storage and surveillance of 3013 packages of stabilized plutonium metals and oxides

  1. Post-tensioning system surveillance program

    International Nuclear Information System (INIS)

    Drew, G.E.

    1979-01-01

    Nuclear power plant containment structure post-tensioning system tendon surveillance program is described in detail. Data collected over three yearly post-tensioning system Surveillance Programs is presented and evaluated to correlate anticipated stress losses with actual losses. In addition corrosion protected system performance is analyzed

  2. An integrated national mortality surveillance system for death registration and mortality surveillance, China.

    Science.gov (United States)

    Liu, Shiwei; Wu, Xiaoling; Lopez, Alan D; Wang, Lijun; Cai, Yue; Page, Andrew; Yin, Peng; Liu, Yunning; Li, Yichong; Liu, Jiangmei; You, Jinling; Zhou, Maigeng

    2016-01-01

    In China, sample-based mortality surveillance systems, such as the Chinese Center for Disease Control and Prevention's disease surveillance points system and the Ministry of Health's vital registration system, have been used for decades to provide nationally representative data on health status for health-care decision-making and performance evaluation. However, neither system provided representative mortality and cause-of-death data at the provincial level to inform regional health service needs and policy priorities. Moreover, the systems overlapped to a considerable extent, thereby entailing a duplication of effort. In 2013, the Chinese Government combined these two systems into an integrated national mortality surveillance system to provide a provincially representative picture of total and cause-specific mortality and to accelerate the development of a comprehensive vital registration and mortality surveillance system for the whole country. This new system increased the surveillance population from 6 to 24% of the Chinese population. The number of surveillance points, each of which covered a district or county, increased from 161 to 605. To ensure representativeness at the provincial level, the 605 surveillance points were selected to cover China's 31 provinces using an iterative method involving multistage stratification that took into account the sociodemographic characteristics of the population. This paper describes the development and operation of the new national mortality surveillance system, which is expected to yield representative provincial estimates of mortality in China for the first time.

  3. Autonomous mobile robotic system for supporting counterterrorist and surveillance operations

    Science.gov (United States)

    Adamczyk, Marek; Bulandra, Kazimierz; Moczulski, Wojciech

    2017-10-01

    Contemporary research on mobile robots concerns applications to counterterrorist and surveillance operations. The goal is to develop systems that are capable of supporting the police and special forces by carrying out such operations. The paper deals with a dedicated robotic system for surveillance of large objects such as airports, factories, military bases, and many others. The goal is to trace unauthorised persons who try to enter to the guarded area, document the intrusion and report it to the surveillance centre, and then warn the intruder by sound messages and eventually subdue him/her by stunning through acoustic effect of great power. The system consists of several parts. An armoured four-wheeled robot assures required mobility of the system. The robot is equipped with a set of sensors including 3D mapping system, IR and video cameras, and microphones. It communicates with the central control station (CCS) by means of a wideband wireless encrypted system. A control system of the robot can operate autonomously, and under remote control. In the autonomous mode the robot follows the path planned by the CCS. Once an intruder has been detected, the robot can adopt its plan to allow tracking him/her. Furthermore, special procedures of treatment of the intruder are applied including warning about the breach of the border of the protected area, and incapacitation of an appropriately selected very loud sound until a patrol of guards arrives. Once getting stuck the robot can contact the operator who can remotely solve the problem the robot is faced with.

  4. MARGINAL EXPENSE OIL WELL WIRELESS SURVEILLANCE MEOWS

    Energy Technology Data Exchange (ETDEWEB)

    Mason M. Medizade; John R. Ridgely; Donald G. Nelson

    2004-11-01

    A marginal expense oil well wireless surveillance system to monitor system performance and production from rod-pumped wells in real time from wells operated by Vaquero Energy in the Edison Field, Main Area of Kern County in California has been successfully designed and field tested. The surveillance system includes a proprietary flow sensor, a programmable transmitting unit, a base receiver and receiving antenna, and a base station computer equipped with software to interpret the data. First, the system design is presented. Second, field data obtained from three wells is shown. Results of the study show that an effective, cost competitive, real-time wireless surveillance system can be introduced to oil fields across the United States and the world.

  5. Reliability demonstration of imaging surveillance systems

    International Nuclear Information System (INIS)

    Sheridan, T.F.; Henderson, J.T.; MacDiarmid, P.R.

    1979-01-01

    Security surveillance systems which employ closed circuit television are being deployed with increasing frequency for the protection of property and other valuable assets. A need exists to demonstrate the reliability of such systems before their installation to assure that the deployed systems will operate when needed with only the scheduled amount of maintenance and support costs. An approach to the reliability demonstration of imaging surveillance systems which employ closed circuit television is described. Failure definitions based on industry television standards and imaging alarm assessment criteria for surveillance systems are discussed. Test methods which allow 24 hour a day operation without the need for numerous test scenarios, test personnel and elaborate test facilities are presented. Existing reliability demonstration standards are shown to apply which obviate the need for elaborate statistical tests. The demonstration methods employed are shown to have applications in other types of imaging surveillance systems besides closed circuit television

  6. Public involvement in environmental surveillance at Hanford

    International Nuclear Information System (INIS)

    Hanf, R.W. Jr.; Patton, G.W.; Woodruff, R.K.; Poston, T.M.

    1994-08-01

    Environmental surveillance at the Hanford Site began during the mid-1940s following the construction and start-up of the nation's first plutonium production reactor. Over the past approximately 45 years, surveillance operations on and off the Site have continued, with virtually all sampling being conducted by Hanford Site workers. Recently, the US Department of Energy Richland Operations Office directed that public involvement in Hanford environmental surveillance operations be initiated. Accordingly, three special radiological air monitoring stations were constructed offsite, near hanford's perimeter. Each station is managed and operated by two local school teaches. These three stations are the beginning of a community-operated environmental surveillance program that will ultimately involve the public in most surveillance operations around the Site. The program was designed to stimulate interest in Hanford environmental surveillance operations, and to help the public better understand surveillance results. The program has also been used to enhance educational opportunities at local schools

  7. Evolution of computer-based surveillance, control and man-machine communication systems in nuclear power stations

    International Nuclear Information System (INIS)

    Wilkinson, H.M.

    1980-01-01

    Reactor surveillance systems, man-machine communication, control methods and system relibility have steadily improved with successive designs. These improvements have been dramatic. Operational results from nine power-reactor units and preliminary results from 12 more units in various phases of implementation are now becoming available. The scope of the improvements ranges from the first design which used only lantern type displays to the latest which uses 18 colour cathode ray tubes (CRT). The operator can bnow scan a parallel presentation of annunciator messages, bar charts and graphical presentations. (orig./HP)

  8. Leishmania Surveillance and Diagnostic Capability in Support of the Joint Biological Agent Identification and Diagnostic System (JBAIDS) and Leishmania Vector Surveillance

    Science.gov (United States)

    2013-02-07

    01-10-09 to 07-02-13 ’+. I II L~ J.\\NU :::OU~ Ill L~ :la. l-UI’I I 11J.\\l- I NUIVI~~I1 LEISHMANIA SURVEILLANCE AND DIAGNOSTIC CAPABILITY IN None...SUPPORT OF THE JOINT BIOLOGICAL AGENT IDENTIFICATION AND :lD. l:JI1J.\\NI NUIVI~~I1 DIAGNOSTIC SYSTEM (JBAIDS) None . ./ LEISHMANIA VECTOR...Field Station at Kisumu completed project activities through a resource sharing arrangement with the 59th MDW. Testing of the Leishmania epidemiology

  9. Resonance sensitivity of hydropower and pumping stations

    Energy Technology Data Exchange (ETDEWEB)

    Popescu, M.; Halanay, A.

    1984-09-01

    Comparative analysis of resonance diagrams for several hydropower and pumping stations with surge tanks and air chambers shows large differences in the maximum resonance pressures. A strategy is advocated which consists of hydraulic resonance computations coupled with practical surveillance measures during the operation of resonance sensitive hydraulic systems. A fundamental hydraulic scheme is considered consisting of a reservoir, a pressure tunnel, a surge tank, a penstock and a turbine combined into a hydropower station. It is suggested that for each hydraulic surge system it is necessary to carry out special resonance analyses following the normal procedure to obtain the resonance sensitivity. For hydraulic systems which are resonance sensitive, mechanical electronic equipment should be used to measure non-stationary pressures of the water in the conduit as a way of continuous surveillance during functioning. 6 references, 6 figures.

  10. 32 CFR 637.20 - Security surveillance systems.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Security surveillance systems. 637.20 Section 637... ENFORCEMENT AND CRIMINAL INVESTIGATIONS MILITARY POLICE INVESTIGATION Investigations § 637.20 Security surveillance systems. Closed circuit video recording systems, to include those with an audio capability, may be...

  11. 47 CFR 87.171 - Class of station symbols.

    Science.gov (United States)

    2010-10-01

    ... RLO—VHF omni-range RLS—Surveillance radar RLT—Radionavigation land test RLW—Microwave landing system RNV—Radio Navigation Land/DME RPC—Ramp Control TJ—Aircraft earth station in the Aeronautical Mobile...

  12. Disaster prevention surveillance system

    International Nuclear Information System (INIS)

    Nara, Satoru; Kamiya, Eisei

    2001-01-01

    Fuji Electric Co., Ltd. has supplied many management systems to nuclear reactor institution. 'The nuclear countermeasures-against-calamities special-measures' was enforced. A nuclear entrepreneur has devised the measure about expansion prevention and restoration of a calamity while it endeavors after prevention of generating of a nuclear calamity. Our company have supplied the 'disaster prevention surveillance system' to the Japan Atomic Energy Research Institute Tokai Research Establishment aiming at strengthening of the monitoring function at the time (after the accident) of the accident used as one of the above-mentioned measures. A 'disaster prevention surveillance system' can share the information on the accident spot in an on-site command place, an activity headquarters, and support organizations, when the serious accident happens. This system is composed of various sensors (temperature, pressure and radiation), cameras, computers and network. (author)

  13. Developments of space station; Uchu station no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, H. [National Space Development Agency of Japan, Tokyo (Japan)

    1996-03-05

    This paper introduces the Japanese experiment module (JEM) in developing a space station. The JEM consists of systems of a pressurizing section, an exposure section, a pressurizing portion of a supply section, a manipulator and an exposure portion of the supply section. The pressurizing section circulates and controls air so that crews can perform experiments under pressurized environment. The exposure section is a part in which experiments are carried out under exposure environment. The supply section runs between a station and the ground, with required devices loaded on it. The manipulator performs attaching a payload for the exposure section and replaces experimental samples. The JEM undergoes a schedule of fabricating an engineering model, testing for a certification a prototype flight model, and putting the model on a flight. The pressurizing section, exposure section and manipulator are at the stage of system tests. Surveillance of the JEM and control of the experiments are carried out at the Tsukuba Space Center. The Center is composed of a space experiment building, a zero-gravity environment testing building, an astronaut training building, a space station operating building, and a space station testing building. 7 figs., 2 tabs.

  14. A GIS-driven integrated real-time surveillance pilot system for national West Nile virus dead bird surveillance in Canada

    Directory of Open Access Journals (Sweden)

    Aramini Jeff

    2006-04-01

    Full Text Available Abstract Background An extensive West Nile virus surveillance program of dead birds, mosquitoes, horses, and human infection has been launched as a result of West Nile virus first being reported in Canada in 2001. Some desktop and web GIS have been applied to West Nile virus dead bird surveillance. There have been urgent needs for a comprehensive GIS services and real-time surveillance. Results A pilot system was developed to integrate real-time surveillance, real-time GIS, and Open GIS technology in order to enhance West Nile virus dead bird surveillance in Canada. Driven and linked by the newly developed real-time web GIS technology, this integrated real-time surveillance system includes conventional real-time web-based surveillance components, integrated real-time GIS components, and integrated Open GIS components. The pilot system identified the major GIS functions and capacities that may be important to public health surveillance. The six web GIS clients provide a wide range of GIS tools for public health surveillance. The pilot system has been serving Canadian national West Nile virus dead bird surveillance since 2005 and is adaptable to serve other disease surveillance. Conclusion This pilot system has streamlined, enriched and enhanced national West Nile virus dead bird surveillance in Canada, improved productivity, and reduced operation cost. Its real-time GIS technology, static map technology, WMS integration, and its integration with non-GIS real-time surveillance system made this pilot system unique in surveillance and public health GIS.

  15. Laser surveillance system for spent fuel

    International Nuclear Information System (INIS)

    Fiarman, S.; Zucker, M.S.; Bieber, A.M. Jr.

    1980-01-01

    A laser surveillance system installed at spent fuel storage pools (SFSP's) will provide the safeguard inspector with specific knowledge of spent fuel movement that cannot be obtained with current surveillance systems. The laser system will allow for the division of the pool's spent fuel inventory into two populations - those assemblies which have been moved and those which haven't - which is essential for maximizing the efficiency and effectiveness of the inspection effort. We have designed, constructed, and tested a full size laser system operating in air and have used an array of 6 zircaloy BWR tubes to simulate an assembly. The reflective signal from the zircaloy rods is a strong function of position of the assembly, but in all cases is easily discernable from the reference scan of the background with no assembly. A design for a SFSP laser surveillance system incorporating laser ranging is discussed. 10 figures

  16. Environmental surveillance of PWR power stations

    International Nuclear Information System (INIS)

    Conti, M.

    1980-01-01

    The action of Electricite de France with respect to the environment of PWR nuclear power stations is essentially centred on prevention. Controls are carried out at two levels: - before the power station goes on stream (radioecological study), - when the power station is operational. The purpose of the controls effected on the radioactive effluents and the environment is to check that the maximum discharge rate stipulated in the corresponding orders is complied with and to ensure that there are no anomalies in the environment [fr

  17. Unattended digital video surveillance: A system prototype for EURATOM safeguards

    International Nuclear Information System (INIS)

    Chare, P.; Goerten, J.; Wagner, H.; Rodriguez, C.; Brown, J.E.

    1994-01-01

    Ever increasing capabilities in video and computer technology have changed the face of video surveillance. From yesterday's film and analog video tape-based systems, we now emerge into the digital era with surveillance systems capable of digital image processing, image analysis, decision control logic, and random data access features -- all of which provide greater versatility with the potential for increased effectiveness in video surveillance. Digital systems also offer other advantages such as the ability to ''compress'' data, providing increased storage capacities and the potential for allowing longer surveillance Periods. Remote surveillance and system to system communications are also a benefit that can be derived from digital surveillance systems. All of these features are extremely important in today's climate Of increasing safeguards activity and decreasing budgets -- Los Alamos National Laboratory's Safeguards Systems Group and the EURATOM Safeguards Directorate have teamed to design and implement a period surveillance system that will take advantage of the versatility of digital video for facility surveillance system that will take advantage of the versatility of digital video for facility surveillance and data review. In this Paper we will familiarize you with system components and features and report on progress in developmental areas such as image compression and region of interest processing

  18. Nadzor vazdušnog prostora pasivnim multisenzorskim sistemima / Air surveillance by passive multisensor systems

    Directory of Open Access Journals (Sweden)

    Miljko Erić

    2004-05-01

    Full Text Available Za sprovođenje savremenih operacija, kako na operativno-strategijskom, tako i na taktič kom nivou, izuzetno je važno da se obezbedi kontinuirani nadzor vazdušnog prostora. Poznato je da su aktivni radarski sistemi, na kojima se kod nas trenutno zasniva nadzor vazdušnog prostora, u ratnim uslovima veoma ranjivi i podložni elektronskim i borbenim dejstvima protivnika, što je u toku rata 1999. godine i praktično potvrđeno. Kao alternativa aktivnim radarskim sistemima nameće se koncept pasivnog nadzora vazdušnog prostora korišćenjem distribuiranih multisenzorskih sistema. Predmet širih istraživanja predstavljaju tehnička rešenja integrisanog multisenzorskog sistema za pasivan nadzor vazdušnog prostora, koji se sastoji od sledećih podsistema za nadzor vazdušnog prostora: na radio-gonimetarskom principu u frekvencijskom opsegu 20-3000 MHz, na zvukometrijskom principu, na principu vizuelnih osmatračkih stanica, na termovizijskom i televizijskom principu. U ovom radu analizirani su opšti principi pasivnog nadzora vazdušnog prostora multisenzorskim sistemima i predložena je tehnička koncepcija radio-goniometarskog i zvukometrijskog podsistema. / It is very important to provide continuous air surveillance in to realize modern operations on the operational-strategic level and tactical, as well. It is well known that active radar systems, on which air surveillance is based in our country, are very vulnerable in war times and susceptible to the electronic counter and combat attacks of the enemy, what is shown practically in 1999 war. Air surveillance by passive multi-sensor systems is a possible alternative to the air surveillance by the active radar systems. Subjects of our wider research are technical solutions of integrated multi-sensor systems for passive air surveillance which consists of the following subsystems: a subsystem for the air communication intelligence within the frequency range 20-3000 MHz based on intercept

  19. Operational experiences on the Borssele nuclear power plant using computer based surveillance and diagnostic system on-line

    International Nuclear Information System (INIS)

    Turkcan, E.; Quaadvliet, W.H.J.; Peeters, T.T.J.M.; Verhoef, J.P

    1991-06-01

    The on-line monitoring and diagnostics system of Borssele nuclear power plant (NPP), designed and established by the ECN Energy Research Foundation, has been operating continuously since 1983. The system is extended in form of multiprocessing, multi-tasking structure performing real-time monitoring, on-line reactor parameters' calculation, data-base preparation for expert systems and providing early information on possible malfunctions even in the incipient stage making alert by passive alarms. The system realized has already been operating in the course of 7 fuel cycles of the reactor starting from start-up through normal power operation. An expert system operating on the VAX work station is added to the surveillance and diagnostics system for data base management of the observed physical parameters relevant to the NPP under supervision. The paper highlights the surveillance and diagnostic modules involved, in their actual hierarchical form in use, presents theoretical considerations applied to the design of the surveillance system together with the results obtained through the 12th to 17th fuel cycles of the NPP including start-ups and shut-downs and reveals the experience thus gained by both utility and ECN through the application of the system described. (author). 19 refs.; 4 figs

  20. Risk analysis of a video-surveillance system

    NARCIS (Netherlands)

    Rothkrantz, L.; Lefter, I.

    2011-01-01

    The paper describes a surveillance system of cameras installed at lamppost of a military area. The surveillance system has been designed to detect unwanted visitors or suspicious behaviors. The area is composed of streets, building blocks and surrounded by gates and water. The video recordings are

  1. Secure Video Surveillance System (SVSS) for unannounced safeguards inspections

    International Nuclear Information System (INIS)

    Galdoz, Erwin G.; Pinkalla, Mark

    2010-01-01

    The Secure Video Surveillance System (SVSS) is a collaborative effort between the U.S. Department of Energy (DOE), Sandia National Laboratories (SNL), and the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC). The joint project addresses specific requirements of redundant surveillance systems installed in two South American nuclear facilities as a tool to support unannounced inspections conducted by ABACC and the International Atomic Energy Agency (IAEA). The surveillance covers the critical time (as much as a few hours) between the notification of an inspection and the access of inspectors to the location in facility where surveillance equipment is installed. ABACC and the IAEA currently use the EURATOM Multiple Optical Surveillance System (EMOSS). This outdated system is no longer available or supported by the manufacturer. The current EMOSS system has met the project objective; however, the lack of available replacement parts and system support has made this system unsustainable and has increased the risk of an inoperable system. A new system that utilizes current technology and is maintainable is required to replace the aging EMOSS system. ABACC intends to replace one of the existing ABACC EMOSS systems by the Secure Video Surveillance System. SVSS utilizes commercial off-the shelf (COTS) technologies for all individual components. Sandia National Laboratories supported the system design for SVSS to meet Safeguards requirements, i.e. tamper indication, data authentication, etc. The SVSS consists of two video surveillance cameras linked securely to a data collection unit. The collection unit is capable of retaining historical surveillance data for at least three hours with picture intervals as short as 1sec. Images in .jpg format are available to inspectors using various software review tools. SNL has delivered two SVSS systems for test and evaluation at the ABACC Safeguards Laboratory. An additional 'proto-type' system remains

  2. Evaluation of HIV Surveillance System in Rivers State, Nigeria ...

    African Journals Online (AJOL)

    Background: Rivers State has been reported to have the highest HIV prevalence of all the thirty-six states in Nigeria. HIV surveillance system generates information for timely and appropriate public health action. Evaluation of the surveillance system is vital in ensuring that the purpose of the surveillance system is being met.

  3. Unattended video surveillance systems for international safeguards

    International Nuclear Information System (INIS)

    Johnson, C.S.

    1979-01-01

    The use of unattended video surveillance systems places some unique requirements on the systems and their hardware. The systems have the traditional requirements of video imaging, video storage, and video playback but also have some special requirements such as tamper safing. The technology available to meet these requirements and how it is being applied to unattended video surveillance systems are discussed in this paper

  4. Internet-based surveillance systems for monitoring emerging infectious diseases.

    Science.gov (United States)

    Milinovich, Gabriel J; Williams, Gail M; Clements, Archie C A; Hu, Wenbiao

    2014-02-01

    Emerging infectious diseases present a complex challenge to public health officials and governments; these challenges have been compounded by rapidly shifting patterns of human behaviour and globalisation. The increase in emerging infectious diseases has led to calls for new technologies and approaches for detection, tracking, reporting, and response. Internet-based surveillance systems offer a novel and developing means of monitoring conditions of public health concern, including emerging infectious diseases. We review studies that have exploited internet use and search trends to monitor two such diseases: influenza and dengue. Internet-based surveillance systems have good congruence with traditional surveillance approaches. Additionally, internet-based approaches are logistically and economically appealing. However, they do not have the capacity to replace traditional surveillance systems; they should not be viewed as an alternative, but rather an extension. Future research should focus on using data generated through internet-based surveillance and response systems to bolster the capacity of traditional surveillance systems for emerging infectious diseases. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Laser surveillance system (LASSY)

    International Nuclear Information System (INIS)

    Boeck, H.; Hammer, J.

    1988-01-01

    The development progress during the reporting period 1988 of the laser surveillance system of spent fuel pools is summarized. The present engineered system comes close to a final version for field application as all technical questions have been solved in 1988. 14 figs., 1 tab. (Author)

  6. Wallops Ship Surveillance System

    Science.gov (United States)

    Smith, Donna C.

    2011-01-01

    Approved as a Wallops control center backup system, the Wallops Ship Surveillance Software is a day-of-launch risk analysis tool for spaceport activities. The system calculates impact probabilities and displays ship locations relative to boundary lines. It enables rapid analysis of possible flight paths to preclude the need to cancel launches and allow execution of launches in a timely manner. Its design is based on low-cost, large-customer- base elements including personal computers, the Windows operating system, C/C++ object-oriented software, and network interfaces. In conformance with the NASA software safety standard, the system is designed to ensure that it does not falsely report a safe-for-launch condition. To improve the current ship surveillance method, the system is designed to prevent delay of launch under a safe-for-launch condition. A single workstation is designated the controller of the official ship information and the official risk analysis. Copies of this information are shared with other networked workstations. The program design is divided into five subsystems areas: 1. Communication Link -- threads that control the networking of workstations; 2. Contact List -- a thread that controls a list of protected item (ocean vessel) information; 3. Hazard List -- threads that control a list of hazardous item (debris) information and associated risk calculation information; 4. Display -- threads that control operator inputs and screen display outputs; and 5. Archive -- a thread that controls archive file read and write access. Currently, most of the hazard list thread and parts of other threads are being reused as part of a new ship surveillance system, under the SureTrak project.

  7. A systems approach for designing a radio station layout for the U.S. National Airspace

    Science.gov (United States)

    Boci, Erton S.

    Today's National Airspace System (NAS) is managed using an aging surveillance radar system. Current radar technology is not adequate to sustain the rapid growth of the commercial, civil, and federal aviation sectors and cannot be adapted to use emerging 21st century airspace surveillance technologies. With 87,000 flights to manage per day, America's ground based radar system has hit a growth ceiling. Consequently, the FAA has embarked on a broad-reaching effort called the Next Generation Air Transportation System (NextGen) that seeks to transform today's aviation airspace management and ensure increased safety and capacity in our NAS. This dissertation presents a systems approach to Service Volume (SV) engineering, a relatively new field of engineering that has emerged in support of the FAA's Automatic Dependent Surveillance -- Broadcast (ADS-B) Air Traffic Modernization Program. SV Engineering is responsible for radio station layout design that would provide the required radio frequency (RF) coverage over a set of Service Volumes, each which represents a section of controlled airspace that is served by a particular air control facility or service. The radio station layout must be optimized to meet system performance, safety, and interference requirements while minimizing the number of radio station sites required to provide RF coverage of the entire airspace of the Unites States. The interference level requirements at the victim (of interference) receivers are the most important and stringent requirements imposed on the ADS-B radio station layout and configuration. In this dissertation, we show a novel and practical way to achieve this optimality by developing and employing several key techniques such as such as reverse radio line-of-site (RLOS) and complex entity-relationship modeling, to address the greater challenges of engineering this complex system. Given that numerous NAS radar facilities are clustered together in relative close proximity to each other, we

  8. A comprehensive review on intelligent surveillance systems

    Directory of Open Access Journals (Sweden)

    Sutrisno Warsono Ibrahim

    2016-05-01

    Full Text Available Intelligent surveillance system (ISS has received growing attention due to the increasing demand on security and safety. ISS is able to automatically analyze image, video, audio or other type of surveillance data without or with limited human intervention. The recent developments in sensor devices, computer vision, and machine learning have an important role in enabling such intelligent system. This paper aims to provide general overview of intelligent surveillance system and discuss some possible sensor modalities and their fusion scenarios such as visible camera (CCTV, infrared camera, thermal camera and radar. This paper also discusses main processing steps in ISS: background-foreground segmentation, object detection and classification, tracking, and behavioral analysis.

  9. Electronic Integrated Disease Surveillance System and Pathogen Asset Control System

    Directory of Open Access Journals (Sweden)

    Tom G. Wahl

    2012-06-01

    Full Text Available Electronic Integrated Disease Surveillance System (EIDSS has been used to strengthen and support monitoring and prevention of dangerous diseases within One Health concept by integrating veterinary and human surveillance, passive and active approaches, case-based records including disease-specific clinical data based on standardised case definitions and aggregated data, laboratory data including sample tracking linked to each case and event with test results and epidemiological investigations. Information was collected and shared in secure way by different means: through the distributed nodes which are continuously synchronised amongst each other, through the web service, through the handheld devices. Electronic Integrated Disease Surveillance System provided near real time information flow that has been then disseminated to the appropriate organisations in a timely manner. It has been used for comprehensive analysis and visualisation capabilities including real time mapping of case events as these unfold enhancing decision making. Electronic Integrated Disease Surveillance System facilitated countries to comply with the IHR 2005 requirements through a data transfer module reporting diseases electronically to the World Health Organisation (WHO data center as well as establish authorised data exchange with other electronic system using Open Architecture approach. Pathogen Asset Control System (PACS has been used for accounting, management and control of biological agent stocks. Information on samples and strains of any kind throughout their entire lifecycle has been tracked in a comprehensive and flexible solution PACS. Both systems have been used in a combination and individually. Electronic Integrated Disease Surveillance System and PACS are currently deployed in the Republics of Kazakhstan, Georgia and Azerbaijan as a part of the Cooperative Biological Engagement Program (CBEP sponsored by the US Defense Threat Reduction Agency (DTRA.

  10. Electronic integrated disease surveillance system and pathogen asset control system.

    Science.gov (United States)

    Wahl, Tom G; Burdakov, Aleksey V; Oukharov, Andrey O; Zhilokov, Azamat K

    2012-06-20

    Electronic Integrated Disease Surveillance System (EIDSS) has been used to strengthen and support monitoring and prevention of dangerous diseases within One Health concept by integrating veterinary and human surveillance, passive and active approaches, case-based records including disease-specific clinical data based on standardised case definitions and aggregated data, laboratory data including sample tracking linked to each case and event with test results and epidemiological investigations. Information was collected and shared in secure way by different means: through the distributed nodes which are continuously synchronised amongst each other, through the web service, through the handheld devices. Electronic Integrated Disease Surveillance System provided near real time information flow that has been then disseminated to the appropriate organisations in a timely manner. It has been used for comprehensive analysis and visualisation capabilities including real time mapping of case events as these unfold enhancing decision making. Electronic Integrated Disease Surveillance System facilitated countries to comply with the IHR 2005 requirements through a data transfer module reporting diseases electronically to the World Health Organisation (WHO) data center as well as establish authorised data exchange with other electronic system using Open Architecture approach. Pathogen Asset Control System (PACS) has been used for accounting, management and control of biological agent stocks. Information on samples and strains of any kind throughout their entire lifecycle has been tracked in a comprehensive and flexible solution PACS.Both systems have been used in a combination and individually. Electronic Integrated Disease Surveillance System and PACS are currently deployed in the Republics of Kazakhstan, Georgia and Azerbaijan as a part of the Cooperative Biological Engagement Program (CBEP) sponsored by the US Defense Threat Reduction Agency (DTRA).

  11. Mobile phone-based syndromic surveillance system, Papua New Guinea.

    Science.gov (United States)

    Rosewell, Alexander; Ropa, Berry; Randall, Heather; Dagina, Rosheila; Hurim, Samuel; Bieb, Sibauk; Datta, Siddhartha; Ramamurthy, Sundar; Mola, Glen; Zwi, Anthony B; Ray, Pradeep; MacIntyre, C Raina

    2013-11-01

    The health care system in Papua New Guinea is fragile, and surveillance systems infrequently meet international standards. To strengthen outbreak identification, health authorities piloted a mobile phone-based syndromic surveillance system and used established frameworks to evaluate whether the system was meeting objectives. Stakeholder experience was investigated by using standardized questionnaires and focus groups. Nine sites reported data that included 7 outbreaks and 92 cases of acute watery diarrhea. The new system was more timely (2.4 vs. 84 days), complete (70% vs. 40%), and sensitive (95% vs. 26%) than existing systems. The system was simple, stable, useful, and acceptable; however, feedback and subnational involvement were weak. A simple syndromic surveillance system implemented in a fragile state enabled more timely, complete, and sensitive data reporting for disease risk assessment. Feedback and provincial involvement require improvement. Use of mobile phone technology might improve the timeliness and efficiency of public health surveillance.

  12. Information Systems to Support Surveillance for Malaria Elimination

    Science.gov (United States)

    Ohrt, Colin; Roberts, Kathryn W.; Sturrock, Hugh J. W.; Wegbreit, Jennifer; Lee, Bruce Y.; Gosling, Roly D.

    2015-01-01

    Robust and responsive surveillance systems are critical for malaria elimination. The ideal information system that supports malaria elimination includes: rapid and complete case reporting, incorporation of related data, such as census or health survey information, central data storage and management, automated and expert data analysis, and customized outputs and feedback that lead to timely and targeted responses. Spatial information enhances such a system, ensuring cases are tracked and mapped over time. Data sharing and coordination across borders are vital and new technologies can improve data speed, accuracy, and quality. Parts of this ideal information system exist and are in use, but have yet to be linked together coherently. Malaria elimination programs should support the implementation and refinement of information systems to support surveillance and response and ensure political and financial commitment to maintain the systems and the human resources needed to run them. National malaria programs should strive to improve the access and utility of these information systems and establish cross-border data sharing mechanisms through the use of standard indicators for malaria surveillance. Ultimately, investment in the information technologies that support a timely and targeted surveillance and response system is essential for malaria elimination. PMID:26013378

  13. Laser surveillance system for spent fuel

    International Nuclear Information System (INIS)

    Fiarman, S.; Zucker, M.S.; Bieber, A.M. Jr.

    1980-01-01

    A laser surveillance system installed at spent fuel storage pools will provide the safeguard inspector with specific knowledge of spent fuel movement that cannot be obtained with current surveillance systems. The laser system will allow for the division of the pool's spent fuel inventory into two populations - those assemblies which have been moved and those which haven't - which is essential for maximizing the efficiency and effectiveness of the inspection effort. We have designed, constructed, and tested a laser system and have used it with a simulated BWR assembly. The reflected signal from the zircaloy rods depends on the position of the assembly, but in all cases is easily discernable from the reference scan of background with no assembly

  14. Multimodal surveillance sensors, algorithms, and systems

    CERN Document Server

    Zhu, Zhigang

    2007-01-01

    From front-end sensors to systems and environmental issues, this practical resource guides you through the many facets of multimodal surveillance. The book examines thermal, vibration, video, and audio sensors in a broad context of civilian and military applications. This cutting-edge volume provides an in-depth treatment of data fusion algorithms that takes you to the core of multimodal surveillance, biometrics, and sentient computing. The book discusses such people and activity topics as tracking people and vehicles and identifying individuals by their speech.Systems designers benefit from d

  15. Mobile Phone–based Syndromic Surveillance System, Papua New Guinea

    Science.gov (United States)

    Ropa, Berry; Randall, Heather; Dagina, Rosheila; Hurim, Samuel; Bieb, Sibauk; Datta, Siddhartha; Ramamurthy, Sundar; Mola, Glen; Zwi, Anthony B.; Ray, Pradeep; MacIntyre, C. Raina

    2013-01-01

    The health care system in Papua New Guinea is fragile, and surveillance systems infrequently meet international standards. To strengthen outbreak identification, health authorities piloted a mobile phone–based syndromic surveillance system and used established frameworks to evaluate whether the system was meeting objectives. Stakeholder experience was investigated by using standardized questionnaires and focus groups. Nine sites reported data that included 7 outbreaks and 92 cases of acute watery diarrhea. The new system was more timely (2.4 vs. 84 days), complete (70% vs. 40%), and sensitive (95% vs. 26%) than existing systems. The system was simple, stable, useful, and acceptable; however, feedback and subnational involvement were weak. A simple syndromic surveillance system implemented in a fragile state enabled more timely, complete, and sensitive data reporting for disease risk assessment. Feedback and provincial involvement require improvement. Use of mobile phone technology might improve the timeliness and efficiency of public health surveillance. PMID:24188144

  16. Evaluation of HIV Surveillance System in Rivers State, Nigeria ...

    African Journals Online (AJOL)

    Sony Computer (Iby)

    HIV surveillance system generates information for timely and appropriate ..... active type of surveillance.14 Nonetheless, it requires training, supervision and motivation ... very effectively.14 The introduction of reward-system could be included.

  17. Verification experiment on the downblending of high enriched uranium (HEU) at the Portsmouth Gaseous Diffusion Plant. Digital video surveillance of the HEU feed stations

    International Nuclear Information System (INIS)

    Martinez, R.L.; Tolk, K.; Whiting, N.; Castleberry, K.; Lenarduzzi, R.

    1998-01-01

    As part of a Safeguards Agreement between the US and the International Atomic Energy Agency (IAEA), the Portsmouth Gaseous Diffusion Plant, Piketon, Ohio, was added to the list of facilities eligible for the application of IAEA safeguards. Currently, the facility is in the process of downblending excess inventory of HEU to low enriched uranium (LEU) from US defense related programs for commercial use. An agreement was reached between the US and the IAEA that would allow the IAEA to conduct an independent verification experiment at the Portsmouth facility, resulting in the confirmation that the HEU was in fact downblended. The experiment provided an opportunity for the DOE laboratories to recommend solutions/measures for new IAEA safeguards applications. One of the measures recommended by Sandia National Laboratories (SNL), and selected by the IAEA, was a digital video surveillance system for monitoring activity at the HEU feed stations. This paper describes the SNL implementation of the digital video system and its integration with the Load Cell Based Weighing System (LCBWS) from Oak Ridge National Laboratory (ORNL). The implementation was based on commercially available technology that also satisfied IAEA criteria for tamper protection and data authentication. The core of the Portsmouth digital video surveillance system was based on two Digital Camera Modules (DMC-14) from Neumann Consultants, Germany

  18. Sonoma Persistent Surveillance System

    Energy Technology Data Exchange (ETDEWEB)

    Pennington, D M

    2006-03-24

    Sonoma offers the first cost-effective, broad-area, high-resolution, real-time motion imagery system for surveillance applications. Sonoma is unique in its ability to provide continuous, real-time video imagery of an area the size of a small city with resolutions sufficient to track 8,000 moving objects in the field of view. At higher resolutions and over smaller areas, Sonoma can even track the movement of individual people. The visual impact of the data available from Sonoma is already causing a paradigm shift in the architecture and operation of other surveillance systems. Sonoma is expected to cost just one-tenth the price of comparably sized sensor systems. Cameras mounted on an airborne platform constantly monitor an area, feeding data to the ground for real-time analysis. Sonoma was designed to provide real-time data for actionable intelligence in situations such as monitoring traffic, special events, border security, and harbors. If a Sonoma system had been available in the aftermath of the Katrina and Rita hurricanes, emergency responders would have had real-time information on roads, water levels, and traffic conditions, perhaps saving many lives.

  19. Survey of Clostridium difficile infection surveillance systems in Europe, 2011.

    Science.gov (United States)

    Kola, Axel; Wiuff, Camilla; Akerlund, Thomas; van Benthem, Birgit H; Coignard, Bruno; Lyytikäinen, Outi; Weitzel-Kage, Doris; Suetens, Carl; Wilcox, Mark H; Kuijper, Ed J; Gastmeier, Petra

    2016-07-21

    To develop a European surveillance protocol for Clostridium difficile infection (CDI), existing national CDI surveillance systems were assessed in 2011. A web-based electronic form was provided for all national coordinators of the European CDI Surveillance Network (ECDIS-Net). Of 35 national coordinators approached, 33 from 31 European countries replied. Surveillance of CDI was in place in 14 of the 31 countries, comprising 18 different nationwide systems. Three of 14 countries with CDI surveillance used public health notification of cases as the route of reporting, and in another three, reporting was limited to public health notification of cases of severe CDI. The CDI definitions published by the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) and the European Centre for Disease Prevention and Control (ECDC) were widely used, but there were differing definitions to distinguish between community- and healthcare-associated cases. All CDI surveillance systems except one reported annual national CDI rates (calculated as number of cases per patient-days). Only four surveillance systems regularly integrated microbiological data (typing and susceptibility testing results). Surveillance methods varied considerably between countries, which emphasises the need for a harmonised European protocol to allow consistent monitoring of the CDI epidemiology at European level. The results of this survey were used to develop a harmonised EU-wide hospital-based CDI surveillance protocol. This article is copyright of The Authors, 2016.

  20. Information systems to support surveillance for malaria elimination.

    Science.gov (United States)

    Ohrt, Colin; Roberts, Kathryn W; Sturrock, Hugh J W; Wegbreit, Jennifer; Lee, Bruce Y; Gosling, Roly D

    2015-07-01

    Robust and responsive surveillance systems are critical for malaria elimination. The ideal information system that supports malaria elimination includes: rapid and complete case reporting, incorporation of related data, such as census or health survey information, central data storage and management, automated and expert data analysis, and customized outputs and feedback that lead to timely and targeted responses. Spatial information enhances such a system, ensuring cases are tracked and mapped over time. Data sharing and coordination across borders are vital and new technologies can improve data speed, accuracy, and quality. Parts of this ideal information system exist and are in use, but have yet to be linked together coherently. Malaria elimination programs should support the implementation and refinement of information systems to support surveillance and response and ensure political and financial commitment to maintain the systems and the human resources needed to run them. National malaria programs should strive to improve the access and utility of these information systems and establish cross-border data sharing mechanisms through the use of standard indicators for malaria surveillance. Ultimately, investment in the information technologies that support a timely and targeted surveillance and response system is essential for malaria elimination. © The American Society of Tropical Medicine and Hygiene.

  1. The multi-camera optical surveillance system (MOS)

    International Nuclear Information System (INIS)

    Otto, P.; Wagner, H.; Richter, B.; Gaertner, K.J.; Laszlo, G.; Neumann, G.

    1991-01-01

    The transition from film camera to video surveillance systems, in particular the implementation of high capacity multi-camera video systems, results in a large increase in the amount of recorded scenes. Consequently, there is a substantial increase in the manpower requirements for review. Moreover, modern microprocessor controlled equipment facilitates the collection of additional data associated with each scene. Both the scene and the annotated information have to be evaluated by the inspector. The design of video surveillance systems for safeguards necessarily has to account for both appropriate recording and reviewing techniques. An aspect of principal importance is that the video information is stored on tape. Under the German Support Programme to the Agency a technical concept has been developed which aims at optimizing the capabilities of a multi-camera optical surveillance (MOS) system including the reviewing technique. This concept is presented in the following paper including a discussion of reviewing and reliability

  2. Youth Risk Behavior Surveillance System

    Science.gov (United States)

    ... Youth Risk Behavior Surveillance System (YRBSS) monitors six types of health-risk behaviors that contribute to the leading causes of death and disability among youth and adults, including— Behaviors that contribute ...

  3. An Autonomous Mobile Robotic System for Surveillance of Indoor Environments

    Directory of Open Access Journals (Sweden)

    Donato Di Paola

    2010-02-01

    Full Text Available The development of intelligent surveillance systems is an active research area. In this context, mobile and multi-functional robots are generally adopted as means to reduce the environment structuring and the number of devices needed to cover a given area. Nevertheless, the number of different sensors mounted on the robot, and the number of complex tasks related to exploration, monitoring, and surveillance make the design of the overall system extremely challenging. In this paper, we present our autonomous mobile robot for surveillance of indoor environments. We propose a system able to handle autonomously general-purpose tasks and complex surveillance issues simultaneously. It is shown that the proposed robotic surveillance scheme successfully addresses a number of basic problems related to environment mapping, localization and autonomous navigation, as well as surveillance tasks, like scene processing to detect abandoned or removed objects and people detection and following. The feasibility of the approach is demonstrated through experimental tests using a multisensor platform equipped with a monocular camera, a laser scanner, and an RFID device. Real world applications of the proposed system include surveillance of wide areas (e.g. airports and museums and buildings, and monitoring of safety equipment.

  4. An Autonomous Mobile Robotic System for Surveillance of Indoor Environments

    Directory of Open Access Journals (Sweden)

    Donato Di Paola

    2010-03-01

    Full Text Available The development of intelligent surveillance systems is an active research area. In this context, mobile and multi-functional robots are generally adopted as means to reduce the environment structuring and the number of devices needed to cover a given area. Nevertheless, the number of different sensors mounted on the robot, and the number of complex tasks related to exploration, monitoring, and surveillance make the design of the overall system extremely challenging. In this paper, we present our autonomous mobile robot for surveillance of indoor environments. We propose a system able to handle autonomously general-purpose tasks and complex surveillance issues simultaneously. It is shown that the proposed robotic surveillance scheme successfully addresses a number of basic problems related to environment mapping, localization and autonomous navigation, as well as surveillance tasks, like scene processing to detect abandoned or removed objects and people detection and following. The feasibility of the approach is demonstrated through experimental tests using a multisensor platform equipped with a monocular camera, a laser scanner, and an RFID device. Real world applications of the proposed system include surveillance of wide areas (e.g. airports and museums and buildings, and monitoring of safety equipment.

  5. The Nigerian health care system: Need for integrating adequate medical intelligence and surveillance systems

    Directory of Open Access Journals (Sweden)

    Menizibeya Osain Welcome

    2011-01-01

    Full Text Available Objectives : As an important element of national security, public health not only functions to provide adequate and timely medical care but also track, monitor, and control disease outbreak. The Nigerian health care had suffered several infectious disease outbreaks year after year. Hence, there is need to tackle the problem. This study aims to review the state of the Nigerian health care system and to provide possible recommendations to the worsening state of health care in the country. To give up-to-date recommendations for the Nigerian health care system, this study also aims at reviewing the dynamics of health care in the United States, Britain, and Europe with regards to methods of medical intelligence/surveillance. Materials and Methods : Databases were searched for relevant literatures using the following keywords: Nigerian health care, Nigerian health care system, and Nigerian primary health care system. Additional keywords used in the search were as follows: United States (OR Europe health care dynamics, Medical Intelligence, Medical Intelligence systems, Public health surveillance systems, Nigerian medical intelligence, Nigerian surveillance systems, and Nigerian health information system. Literatures were searched in scientific databases Pubmed and African Journals OnLine. Internet searches were based on Google and Search Nigeria. Results : Medical intelligence and surveillance represent a very useful component in the health care system and control diseases outbreak, bioattack, etc. There is increasing role of automated-based medical intelligence and surveillance systems, in addition to the traditional manual pattern of document retrieval in advanced medical setting such as those in western and European countries. Conclusion : The Nigerian health care system is poorly developed. No adequate and functional surveillance systems are developed. To achieve success in health care in this modern era, a system well grounded in routine

  6. SCORPIO - VVER core surveillance system

    International Nuclear Information System (INIS)

    Zalesky, K.; Svarny, J.; Novak, L.; Rosol, J.; Horanes, A.

    1997-01-01

    The Halden Project has developed the core surveillance system SCORPIO which has two parallel modes of operation: the Core Follow Mode and the Predictive Mode. The main motivation behind the development of SCORPIO is to make a practical tool for reactor operators which can increase the quality and quantity of information presented on core status and dynamic behavior. This can first of all improve plant safety as undesired core conditions are detected and prevented. Secondly, more flexible and efficient plant operation is made possible. So far the system has only been implemented on western PWRs but the basic concept is applicable to a wide range of reactor including WWERs. The main differences between WWERs and typical western PWRs with respect to core surveillance requirements are outlined. The development of a WWER version of SCORPIO was initiated in cooperation with the Nuclear Research Institute at Rez and industry partners in the Czech Republic. The first system will be installed at the Dukovany NPP. (author)

  7. The PADE dosimetry system at the Brokdorf nuclear power station

    International Nuclear Information System (INIS)

    Poetter, Karl-Friedrich; Eckelmann, Joerg; Kuegow, Mario; Spahn, Werner; Franz, Manfred

    2002-01-01

    The PADE program system is used in nuclear power plants for personnel and workplace dosimetry and for managing access to the controlled area. On-line interfaces with existing dose determination systems allow collection, surveillance and evaluation functions to be achieved for person-related and workplace-related dose data. This is managed by means of open, non-proprietary communication of PADE with the computer system coupled via interfaces. In systems communication, PADE is limited to main interventions into outside systems, thus ensuring flexible adaptation to existing systems. As a client-server solution, PADE has been developed on the basis of an ORACLE-8 database; the version presented here runs on a Windows NT server. The system described has been used at the Brokdorf Nuclear Power Station since early 2000 and has so far reliably managed more than one million individual access movements of more than 6 000 persons. It is currently being integrated into a comprehensive plant operations management system. Among other things, PADE offers a considerable development potential for a tentatively planned future standardization of parts of the dosimetry systems in German nuclear power plants and for the joint management of in-plant and official dose data. (orig.) [de

  8. Second Generation of HIV Surveillance System: A Pattern for Iran

    OpenAIRE

    Nematollahi, M; Khalesi, N; Moghaddasi, H; Askarian, M

    2012-01-01

    Background For the purpose of minimizing the HIV/AIDS epidemic effects, one of the programs is the promotion of scientific methods and setting of the suitable surveillance systems. The present research was conducted to design the HIV/AIDS surveillance system in Iran applying WHO recommendations and the experience of some countries. Methods In 2009, based on the country's requirements, the HIV/AIDS surveillance system was proposed and designed for Iran. The Delphi technique was utilized to fin...

  9. Web-based infectious disease surveillance systems and public health perspectives: a systematic review

    Directory of Open Access Journals (Sweden)

    Jihye Choi

    2016-12-01

    Full Text Available Abstract Background Emerging and re-emerging infectious diseases are a significant public health concern, and early detection and immediate response is crucial for disease control. These challenges have led to the need for new approaches and technologies to reinforce the capacity of traditional surveillance systems for detecting emerging infectious diseases. In the last few years, the availability of novel web-based data sources has contributed substantially to infectious disease surveillance. This study explores the burgeoning field of web-based infectious disease surveillance systems by examining their current status, importance, and potential challenges. Methods A systematic review framework was applied to the search, screening, and analysis of web-based infectious disease surveillance systems. We searched PubMed, Web of Science, and Embase databases to extensively review the English literature published between 2000 and 2015. Eleven surveillance systems were chosen for evaluation according to their high frequency of application. Relevant terms, including newly coined terms, development and classification of the surveillance systems, and various characteristics associated with the systems were studied. Results Based on a detailed and informative review of the 11 web-based infectious disease surveillance systems, it was evident that these systems exhibited clear strengths, as compared to traditional surveillance systems, but with some limitations yet to be overcome. The major strengths of the newly emerging surveillance systems are that they are intuitive, adaptable, low-cost, and operated in real-time, all of which are necessary features of an effective public health tool. The most apparent potential challenges of the web-based systems are those of inaccurate interpretation and prediction of health status, and privacy issues, based on an individual’s internet activity. Conclusion Despite being in a nascent stage with further modification

  10. Kestrel: force protection and Intelligence, Surveillance, and Reconnaissance (ISR) persistent surveillance on aerostats

    Science.gov (United States)

    Luber, David R.; Marion, John E.; Fields, David

    2012-05-01

    Logos Technologies has developed and fielded the Kestrel system, an aerostat-based, wide area persistent surveillance system dedicated to force protection and ISR mission execution operating over forward operating bases. Its development included novel imaging and stabilization capability for day/night operations on military aerostat systems. The Kestrel system's contribution is a substantial enhancement to aerostat-based, force protection systems which to date have relied on narrow field of view ball gimbal sensors to identify targets of interest. This inefficient mechanism to conduct wide area field of view surveillance is greatly enhanced by Kestrel's ability to maintain a constant motion imagery stare of the entire forward operating base (FOB) area. The Kestrel airborne sensor enables 360° coverage out to extended ranges which covers a city sized area at moderate resolution, while cueing a narrow field of view sensor to provide high resolution imagery of targets of interest. The ground station exploitation system enables operators to autonomously monitor multiple regions of interest in real time, and allows for backtracking through the recorded imagery, while continuing to monitor ongoing activity. Backtracking capability allows operators to detect threat networks, their CONOPS, and locations of interest. Kestrel's unique advancement has already been utilized successfully in OEF operations.

  11. Surveillance System for Infectious Diseases of Pets, Santiago, Chile

    Science.gov (United States)

    López, Javier; Abarca, Katia; Valenzuela, Berta; Lorca, Lilia; Olea, Andrea; Aguilera, Ximena

    2009-01-01

    Pet diseases may pose risks to human health but are rarely included in surveillance systems. A pilot surveillance system of pet infectious diseases in Santiago, Chile, found that 4 canine and 3 feline diseases accounted for 90.1% and 98.4% of notifications, respectively. Data also suggested association between poverty and pet diseases. PMID:19861073

  12. SCORPIO - WWER core surveillance system

    International Nuclear Information System (INIS)

    Hornaes, Arne; Bodal, Terje; Sunde, Svein; Zalesky, K.; Lehman, M.; Pecka, M.; Svarny, J.; Krysl, V.; Juzova, Z.; Sedlak, A.; Semmler, M.

    1998-01-01

    The Institut for energiteknikk has developed the core surveillance system SCORPIO, which has two parallel modes of operation: the Core Follow Mode and the Predictive Mode. The main motivation behind the development of SCORPIO is to make a practical tool for reactor operators which can increase the quality and quantity of information presented on core status and dynamic behavior. This can first of all improve plant safety, as undesired core conditions are detected and prevented. Secondly, more flexible and efficient plant operation is made possible. The system has been implemented on western PWRs, but the basic concept is applicable to a wide range of reactors including WWERs. The main differences between WWERs and typical western PWRs with respect to core surveillance requirements are outlined. The development of a WWER version of SCORPIO has been done in co-operation with the Nuclear Research Institute Rez, and industry partners in the Czech Republic. The first system is installed at Dukovany NPP, where the Site Acceptance Test was completed 6. March 1998.(Authors)

  13. SCORPIO - VVER core surveillance system

    International Nuclear Information System (INIS)

    Hornaes, A.; Bodal, T.; Sunde, S.

    1998-01-01

    The Institutt for energiteknikk has developed the core surveillance system SCORPIO, which has two parallel modes of operation: the Core Follow Mode and the Predictive Mode. The main motivation behind the development of SCORPIO is to make a practical tool for reactor operators, which can increase the quality and quantity of information presented on core status and dynamic behavior. This can first of all improve plant safety, as undesired core conditions are detected and prevented. Secondly, more flexible and efficient plant operation is made possible. The system has been implemented on western PWRs, but the basic concept is applicable to a wide range of reactors including VVERs. The main differences between VVERs and typical western PWRs with respect to core surveillance requirements are outlined. The development of a VVER version of SCORPIO has been done in co-operation with the Nuclear Research Institute Rez, and industry partners in the Czech Republic. The first system is installed at Dukovany NPP, where the Site Acceptance Test was completed 6. March 1998.(author)

  14. Design and implementation of distributed multimedia surveillance system based on object-oriented middleware

    Science.gov (United States)

    Cao, Xuesong; Jiang, Ling; Hu, Ruimin

    2006-10-01

    Currently, the applications of surveillance system have been increasingly widespread. But there are few surveillance platforms that can meet the requirement of large-scale, cross-regional, and flexible surveillance business. In the paper, we present a distributed surveillance system platform to improve safety and security of the society. The system is constructed by an object-oriented middleware called as Internet Communications Engine (ICE). This middleware helps our platform to integrate a lot of surveillance resource of the society and accommodate diverse range of surveillance industry requirements. In the follow sections, we will describe in detail the design concepts of system and introduce traits of ICE.

  15. Space Station power system issues

    International Nuclear Information System (INIS)

    Giudici, R.J.

    1985-01-01

    Issues governing the selection of power systems for long-term manned Space Stations intended solely for earth orbital missions are covered briefly, drawing on trade study results from both in-house and contracted studies that have been conducted over nearly two decades. An involvement, from the Program Development Office at MSFC, with current Space Station concepts began in late 1982 with the NASA-wide Systems Definition Working Group and continued throughout 1984 in support of various planning activities. The premise for this discussion is that, within the confines of the current Space Station concept, there is good reason to consider photovoltaic power systems to be a venerable technology option for both the initial 75 kW and 300 kW (or much greater) growth stations. The issue of large physical size required by photovoltaic power systems is presented considering mass, atmospheric drag, launch packaging and power transmission voltage as being possible practicality limitations. The validity of searching for a cross-over point necessitating the introduction of solar thermal or nuclear power system options as enabling technologies is considered with reference to programs ranging from the 4.8 kW Skylab to the 9.5 gW Space Power Satellite

  16. CDC Behavioral Risk Factor Surveillance System (BRFSS)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Behavioral Risk Factor Surveillance System (BRFSS) is a state-based system of health surveys that collects information on health risk behaviors, preventive...

  17. Next Generation Space Surveillance System-of-Systems

    Science.gov (United States)

    McShane, B.

    2014-09-01

    International economic and military dependence on space assets is pervasive and ever-growing in an environment that is now congested, contested, and competitive. There are a number of natural and man-made risks that need to be monitored and characterized to protect and preserve the space environment and the assets within it. Unfortunately, today's space surveillance network (SSN) has gaps in coverage, is not resilient, and has a growing number of objects that get lost. Risks can be efficiently and effectively mitigated, gaps closed, resiliency improved, and performance increased within a next generation space surveillance network implemented as a system-of-systems with modern information architectures and analytic techniques. This also includes consideration for the newest SSN sensors (e.g. Space Fence) which are born Net-Centric out-of-the-box and able to seamlessly interface with the JSpOC Mission System, global information grid, and future unanticipated users. Significant opportunity exists to integrate legacy, traditional, and non-traditional sensors into a larger space system-of-systems (including command and control centers) for multiple clients through low cost sustainment, modification, and modernization efforts. Clients include operations centers (e.g. JSpOC, USSTRATCOM, CANSPOC), Intelligence centers (e.g. NASIC), space surveillance sensor sites (e.g. AMOS, GEODSS), international governments (e.g. Germany, UK), space agencies (e.g. NASA), and academic institutions. Each has differing priorities, networks, data needs, timeliness, security, accuracy requirements and formats. Enabling processes and technologies include: Standardized and type accredited methods for secure connections to multiple networks, machine-to-machine interfaces for near real-time data sharing and tip-and-queue activities, common data models for analytical processing across multiple radar and optical sensor types, an efficient way to automatically translate between differing client and

  18. Nuclear safeguards control in nuclear power stations

    International Nuclear Information System (INIS)

    Boedege, R.; Braatz, U.; Heger, H.

    1976-01-01

    The execution of the Non-Proliferation Treaty (NPT) has initiated a third phase in the efforts taken to ensure peace by limiting the number of atomic powers. In this phase it is important, above all, to turn into workable systems the conditions imposed upon technology by the different provisions of the Verification Agreement of the NPT. This is achieved mainly by elaborating annexes to the Agreement specifically geared to certain model plants, typical representatives selected for LWR power stations being the plants at Garigliano, Italy (BWR), and Stade, Federal Republic of Germany (PWR). The surveillance measures taken to prevent any diversion of special nuclear material for purposes of nuclear weapons manufacture must be effective in achieving their specific objective and must not impede the circumspect management of operations of the plants concerned. A VDEW working party has studied the technical details of the planned surveillance measures in nuclear power stations in the Federal Republic of Germany and now presents a concept of material balancing by units which meets the conditions imposed by the inspection authority and could also be accepted by the operators of nuclear power stations. The concept provides for uninterrupted control of the material balance areas of the nuclear power stations concerned, allows continuous control of the whole nuclear fuel cycle, is based exclusively on existing methods and facilities, and can be implemented at low cost. (orig.) [de

  19. Youth Risk Behavior Surveillance System (YRBSS)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Youth Risk Behavior Surveillance System (YRBSS) monitors 6 types of health-risk behaviors that contribute to the leading causes of death and disability among...

  20. Designing and evaluating risk-based surveillance systems

    DEFF Research Database (Denmark)

    Willeberg, Preben; Nielsen, Liza Rosenbaum; Salman, Mo

    2012-01-01

    Risk-based surveillance systems reveal occurrence of disease or infection in a sample of population units, which are selected on the basis of risk factors for the condition under study. The purpose of such systems for supporting practical animal disease policy formulations and management decisions...... with prudent use of resources while maintaining acceptable system performance. High-risk category units are selected for testing by identification of the presence of specific high-risk factor(s), while disregarding other factors that might also influence the risk. On this basis we argue that the most...... applicable risk estimate for use in designing and evaluating a risk-based surveillance system would be a crude (unadjusted) relative risk, odds ratio or apparent prevalence. Risk estimates found in the published literature, however, are often the results of multivariable analyses implicitly adjusting...

  1. Descriptive review of tuberculosis surveillance systems across the circumpolar regions

    Directory of Open Access Journals (Sweden)

    Annie-Claude Bourgeois

    2016-04-01

    Full Text Available Background: Tuberculosis is highly prevalent in many Arctic areas. Members of the International Circumpolar Surveillance Tuberculosis (ICS-TB Working Group collaborate to increase knowledge about tuberculosis in Arctic regions. Objective: To establish baseline knowledge of tuberculosis surveillance systems used by ICS-TB member jurisdictions. Design: Three questionnaires were developed to reflect the different surveillance levels (local, regional and national; all 3 were forwarded to the official representative of each of the 15 ICS-TB member jurisdictions in 2013. Respondents self-identified the level of surveillance conducted in their region and completed the applicable questionnaire. Information collected included surveillance system objectives, case definitions, data collection methodology, storage and dissemination. Results: Thirteen ICS-TB jurisdictions [Canada (Labrador, Northwest Territories, Nunavik, Nunavut, Yukon, Finland, Greenland, Norway, Sweden, Russian Federation (Arkhangelsk, Khanty-Mansiysk Autonomous Okrug, Yakutia (Sakha Republic, United States (Alaska] voluntarily completed the survey – representing 2 local, 7 regional and 4 national levels. Tuberculosis reporting is mandatory in all jurisdictions, and case definitions are comparable across regions. The common objectives across systems are to detect outbreaks, and inform the evaluation/planning of public health programmes and policies. All jurisdictions collect data on confirmed active tuberculosis cases and treatment outcomes; 11 collect contact tracing results. Faxing of standardized case reporting forms is the most common reporting method. Similar core data elements are collected; 8 regions report genotyping results. Data are stored using customized programmes (n=7 and commercial software (n=6. Nine jurisdictions provide monthly, bi-annual or annual reports to principally government and/or scientific/medical audiences. Conclusion: This review successfully establishes

  2. Feasibility of using pedometers in a state-based surveillance system: 2014 Arizona Behavioral Risk Factor Surveillance System

    Directory of Open Access Journals (Sweden)

    Alberto Flórez-Pregonero

    2018-01-01

    Conclusion: The feasibility of using pedometers in a state-based surveillance system is modest at best. Feasibility may potentially be improved with easy-to-use pedometers where data can be electronically downloaded.

  3. Surveillance and early warning systems of infectious disease in China: From 2012 to 2014.

    Science.gov (United States)

    Zhang, Honglong; Wang, Liping; Lai, Shengjie; Li, Zhongjie; Sun, Qiao; Zhang, Peng

    2017-07-01

    Appropriate surveillance and early warning of infectious diseases have very useful roles in disease control and prevention. In 2004, China established the National Notifiable Infectious Disease Surveillance System and the Public Health Emergency Event Surveillance System to report disease surveillance and events on the basis of data sources from the National Notifiable Infectious Disease Surveillance System, China Infectious Disease Automated-alert and Response System in this country. This study provided a descriptive summary and a data analysis, from 2012 to 2014, of these 3 key surveillance and early warning systems of infectious disease in China with the intent to provide suggestions for system improvement and perfection. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Space Station Environmental Control/Life Support System engineering

    Science.gov (United States)

    Miller, C. W.; Heppner, D. B.

    1985-01-01

    The present paper is concerned with a systems engineering study which has provided an understanding of the overall Space Station ECLSS (Environmental Control and Life Support System). ECLSS/functional partitioning is considered along with function criticality, technology alternatives, a technology description, single thread systems, Space Station architectures, ECLSS distribution, mechanical schematics per space station, and Space Station ECLSS characteristics. Attention is given to trade studies and system synergism. The Space Station functional description had been defined by NASA. The ECLSS will utilize technologies which embody regenerative concepts to minimize the use of expendables.

  5. Smart sensing surveillance system

    Science.gov (United States)

    Hsu, Charles; Chu, Kai-Dee; O'Looney, James; Blake, Michael; Rutar, Colleen

    2010-04-01

    An effective public safety sensor system for heavily-populated applications requires sophisticated and geographically-distributed infrastructures, centralized supervision, and deployment of large-scale security and surveillance networks. Artificial intelligence in sensor systems is a critical design to raise awareness levels, improve the performance of the system and adapt to a changing scenario and environment. In this paper, a highly-distributed, fault-tolerant, and energy-efficient Smart Sensing Surveillance System (S4) is presented to efficiently provide a 24/7 and all weather security operation in crowded environments or restricted areas. Technically, the S4 consists of a number of distributed sensor nodes integrated with specific passive sensors to rapidly collect, process, and disseminate heterogeneous sensor data from near omni-directions. These distributed sensor nodes can cooperatively work to send immediate security information when new objects appear. When the new objects are detected, the S4 will smartly select the available node with a Pan- Tilt- Zoom- (PTZ) Electro-Optics EO/IR camera to track the objects and capture associated imagery. The S4 provides applicable advanced on-board digital image processing capabilities to detect and track the specific objects. The imaging detection operations include unattended object detection, human feature and behavior detection, and configurable alert triggers, etc. Other imaging processes can be updated to meet specific requirements and operations. In the S4, all the sensor nodes are connected with a robust, reconfigurable, LPI/LPD (Low Probability of Intercept/ Low Probability of Detect) wireless mesh network using Ultra-wide band (UWB) RF technology. This UWB RF technology can provide an ad-hoc, secure mesh network and capability to relay network information, communicate and pass situational awareness and messages. The Service Oriented Architecture of S4 enables remote applications to interact with the S4

  6. Space Station data management system architecture

    Science.gov (United States)

    Mallary, William E.; Whitelaw, Virginia A.

    1987-01-01

    Within the Space Station program, the Data Management System (DMS) functions in a dual role. First, it provides the hardware resources and software services which support the data processing, data communications, and data storage functions of the onboard subsystems and payloads. Second, it functions as an integrating entity which provides a common operating environment and human-machine interface for the operation and control of the orbiting Space Station systems and payloads by both the crew and the ground operators. This paper discusses the evolution and derivation of the requirements and issues which have had significant effect on the design of the Space Station DMS, describes the DMS components and services which support system and payload operations, and presents the current architectural view of the system as it exists in October 1986; one-and-a-half years into the Space Station Phase B Definition and Preliminary Design Study.

  7. Developing a surveillance system for HIV/AIDS in Pakistan

    International Nuclear Information System (INIS)

    Emmanuel, F.; Bokhari, A.

    2006-01-01

    Apart from other interventions, surveillance remains a major focus of the national response to HIV/AIDS. However, with a shift in the epidemic pattern, the existing surveillance strategies are barely insufficient and long-term structural changes are desirable. This article provides a conceptual framework for developing a scientific system for HIV surveillance in Pakistan. Second generation surveillance system including repeated cross-sectional surveys in high risk population groups are suggested to collect behavioral and serological data at regular intervals on an annual basis to monitor the epidemic trend as well as the associated behaviors. In addition, multiple data resources have been highlighted, which could be coordinated to describe the epidemic pattern in the country. This information should form the basis for national prevention planning and ought to be used for making sensible choices through which prevention efforts are most likely to reduce new infections. (author)

  8. Space stations systems and utilization

    CERN Document Server

    Messerschmid, Ernst

    1999-01-01

    The design of space stations like the recently launched ISS is a highly complex and interdisciplinary task. This book describes component technologies, system integration, and the potential usage of space stations in general and of the ISS in particular. It so adresses students and engineers in space technology. Ernst Messerschmid holds the chair of space systems at the University of Stuttgart and was one of the first German astronauts.

  9. Science and engineering intelligent surveillance systems

    CERN Document Server

    Huihuan, Qian; Xu, Yangsheng

    2011-01-01

    As shortcomings such as high labor costs make intelligent surveillance systems more desirable, this practical book focuses on detecting abnormal behavior based on learning and the analysis of dangerous crowd behavior based on texture and optical flow.

  10. Strengthening Injury Surveillance System in Iran

    Directory of Open Access Journals (Sweden)

    Motevalian Seyed Abbas

    2012-02-01

    Full Text Available 【Abstract】Objective: To strengthen the current Injury Surveillance System (IS System in order to better monitor injury conditions, improve protection ways and promote safety. Methods: At first we carried out a study to evaluate the frameworks of IS System in the developed countries. Then all the available documents from World Health Organization, Eastern Mediterranean Regional Organization, as well as Minister of Health and Medical Education concerning Iran were reviewed. Later a national stakeholder抯 consultation was held to collect opinions and views. A national workshop was also intended for provincial representatives from 41 universities to identify the barriers and limitations of the existing program and further to strengthen injury surveillance. Results: The evaluation of the current IS System revealed many problems, mainly presented as lack of accurate pre- and post-hospital death registry, need of precise injury data registry in outpatient medical centers, incomplete injury data registry in hospitals and lack of accuracy in definition of variables in injury registry. The five main characteristics of current IS System including flexibility, acceptability, simplicity, usefulness and timeliness were evaluated as moderate by experts. Conclusions: Major revisions must be considered in the current IS System in Iran. The following elements should be added to the questionnaire: identifier, manner of arrival to the hospital, situation of the injured patient, consumption of alcohol and opioids, other involved participants in the accident, intention, severity and site of injury, side effects of surgery and medication, as well as one month follow-up results. Data should be collected from 10% of all hospitals in Iran and analyzed every 3 months. Simultaneously data should be online to be retrieved by researches. Key words: Wounds and injuries; Population surveillance; Registries; Iran

  11. Next generation surveillance system (NGSS)

    International Nuclear Information System (INIS)

    Aparo, Massimo

    2006-01-01

    Development of 'functional requirements' for transparency systems may offer a near-term mode of regional cooperation. New requirements under development at the IAEA may provide a foundation for this potential activity. The Next Generation Surveillance System (NGSS) will become the new IAEA remote monitoring system Under new requirements the NGSS would attempt to use more commercial components to reduce cost, increase radiation survivability and further increase reliability. The NGSS must be available in two years due to rapidly approaching obsolescence in the existing DCM family. (author)

  12. Developing a new syndromic surveillance system for the London 2012 Olympic and Paralympic Games.

    Science.gov (United States)

    Harcourt, S E; Fletcher, J; Loveridge, P; Bains, A; Morbey, R; Yeates, A; McCloskey, B; Smyth, B; Ibbotson, S; Smith, G E; Elliot, A J

    2012-12-01

    Syndromic surveillance is vital for monitoring public health during mass gatherings. The London 2012 Olympic and Paralympic Games represents a major challenge to health protection services and community surveillance. In response to this challenge the Health Protection Agency has developed a new syndromic surveillance system that monitors daily general practitioner out-of-hours and unscheduled care attendances. This new national system will fill a gap identified in the existing general practice-based syndromic surveillance systems by providing surveillance capability of general practice activity during evenings/nights, over weekends and public holidays. The system will complement and supplement the existing tele-health phone line, general practitioner and emergency department syndromic surveillance systems. This new national system will contribute to improving public health reassurance, especially to meet the challenges of the London 2012 Olympic and Paralympic Games.

  13. Considerations on a VXI based digital image surveillance system

    International Nuclear Information System (INIS)

    Gaertner, K.J.; Neumann, G.; Richter, B.

    1995-01-01

    In 1992 the International Atomic Energy Agency established the IAEA Integrated Safeguards Instrumentation Programme (I 2 SIP) which provides a conceptual framework to guide new equipment development activities. One of the main goals of I 2 SIP is to define the optimum structure of future safeguards equipment inventory that would enable the integration of containment, surveillance and unattended radiation monitoring modules for application in facilities with complex safeguards systems. This approach implies a modular equipment structure in both hardware and software. In December 1993, a Consultants Meeting concluded that the VXI instrument bus (VXIbus) standard does not appear to have any technical limitations that will inhibit the use of I 2 SIP and should be considered the first choice for future safeguards equipment. The Agency's development plan for Digital Image Surveillance (DIS) is part of the I 2 SIP and has defined the need for 'distributed systems', i.e. for multichannel surveillance systems, which should accommodate the integration aspect and meet requirements for both mail-in of recorded information to the Agency and remote surveillance. The paper describes the basic considerations that have led to the selection of the VXI bus to be used for such a system including the different modules emphasizing the integration issue

  14. Remote-Reading Safety and Safeguards Surveillance System for 3013 Containers

    International Nuclear Information System (INIS)

    Lechelt, W. M.; Skorpik, J. R.; Silvers, K. L.; Szempruch, R. W.; Douglas, D. G.; Fein, K. O.

    2002-01-01

    At Hanford's Plutonium Finishing Plant (PFP), plutonium oxide is being loaded into stainless steel containers for long-term storage on the Hanford Site. These containers consist of two weld-sealed stainless steel cylinders nested one within the other. A third container holds the plutonium within the inner cylinder. This design meets the U.S. Department of Energy (DOE) storage standard, DOE-STD- 3013-2000, which anticipates a 50-year storage lifetime. The 3013 standard also requires a container surveillance program to continuously monitor pressure and to assure safeguards are adequate. However, the configuration of the container system makes using conventional measurement and monitoring methods difficult. To better meet the 3013 monitoring requirements, a team from Fluor Hanford (who manages the PFP), Pacific Northwest National Laboratory (PNNL), and Vista Engineering Technologies, LLC, developed a safer, cost-efficient, remote PFP 3013 container surveillance system. This new surveillance system is a combination of two successfully deployed technologies: (1) a magnetically coupled pressure gauge developed by Vista Engineering and (2) a radio frequency (RF) tagging device developed by PNNL. This system provides continuous, 100% monitoring of critical parameters with the containers in place, as well as inventory controls. The 3013 container surveillance system consists of three main elements: (1) an internal magnetic pressure sensor package, (2) an instrument pod (external electronics package), and (3) a data acquisition storage and display computer. The surveillance system described in this paper has many benefits for PFP and DOE in terms of cost savings and reduced personnel exposure. In addition, continuous safety monitoring (i.e., internal container pressure and temperature) of every container is responsible nuclear material stewardship and fully meets and exceeds DOE's Integrated Surveillance Program requirements

  15. Comparing national infectious disease surveillance systems: China and the Netherlands.

    Science.gov (United States)

    Vlieg, Willemijn L; Fanoy, Ewout B; van Asten, Liselotte; Liu, Xiaobo; Yang, Jun; Pilot, Eva; Bijkerk, Paul; van der Hoek, Wim; Krafft, Thomas; van der Sande, Marianne A; Liu, Qi-Yong

    2017-05-08

    Risk assessment and early warning (RAEW) are essential components of any infectious disease surveillance system. In light of the International Health Regulations (IHR)(2005), this study compares the organisation of RAEW in China and the Netherlands. The respective approaches towards surveillance of arboviral disease and unexplained pneumonia were analysed to gain a better understanding of the RAEW mode of operation. This study may be used to explore options for further strengthening of global collaboration and timely detection and surveillance of infectious disease outbreaks. A qualitative study design was used, combining data retrieved from the literature and from semi-structured interviews with Chinese (5 national-level and 6 provincial-level) and Dutch (5 national-level) experts. The results show that some differences exist such as in the use of automated electronic components of the early warning system in China ('CIDARS'), compared to a more limited automated component in the Netherlands ('barometer'). Moreover, RAEW units in the Netherlands focus exclusively on infectious diseases, while China has a broader 'all hazard' approach (including for example chemical incidents). In the Netherlands, veterinary specialists take part at the RAEW meetings, to enable a structured exchange/assessment of zoonotic signals. Despite these differences, the main conclusion is that for the two infections studied, the early warning system in China and the Netherlands are remarkably similar considering their large differences in infectious disease history, population size and geographical setting. Our main recommendations are continued emphasis on international corporation that requires insight into national infectious disease surveillance systems, the usage of a One Health approach in infectious disease surveillance, and further exploration/strengthening of a combined syndromic and laboratory surveillance system.

  16. Will smart surveillance systems listen, understand and speak Slovene?

    Directory of Open Access Journals (Sweden)

    Simon Dobrišek

    2013-12-01

    Full Text Available The paper deals with the spoken language technologies that could enable the so-called smart (intelligent surveillance systems to listen, understand and speak Slovenian in the near future. Advanced computational methods of artificial perception and pattern recognition enable such systems to be at least to some extent aware of the environment, the presence of people and other phenomena that could be subject to surveillance. Speech is one such phenomenon that has the potential to be a key source of information in certain security situations. Technologies that enable automatic speech and speaker recognition as well as their psychophysical state by computer analysis of acoustic speech signals provide an entirely new dimension to the development of smart surveillance systems. Automatic recognition of spoken threats, screaming and crying for help, as well as a suspicious psycho-physical state of a speaker provide such systems to some extent with intelligent behaviour. The paper investigates the current state of development of these technologies and the requirements and possibilities of these systems to be used for the Slovenian spoken language, as well as different possible security application scenarios. It also addresses the broader legal and ethical issues raised by the development and use of such technologies, especially as audio surveillance is one of the most sensitive issues of privacy protection.

  17. Wireless sensor network for mobile surveillance systems; 2005BU1-TRSP

    NARCIS (Netherlands)

    Maris, M.G.; Dijk, G.J.A. van

    2005-01-01

    Guarding safety and security within industrial, commercial and military areas is an important issue nowadays. A specific challenge lies in the design of portable surveillance systems that can be rapidly deployed, installed and easily operated. Conventional surveillance systems typically employ

  18. Is the HIV sentinel surveillance system adequate in China? Findings from an evaluation of the national HIV sentinel surveillance system

    Directory of Open Access Journals (Sweden)

    Marc Bulterys

    2012-11-01

    Full Text Available Background: An external evaluation was conducted to assess the performance of the national HIV sentinel surveillance system (HSS, identify operational challenges at national and local levels and provide recommendations for improvement.Methods: The United States Centers for Disease Control and Prevention’s (CDC Updated Guidelines for Evaluating Public Health Surveillance Systems were followed to assess the key attributes of HSS. Comprehensive assessment activities were conducted, including: using a detailed checklist to review surveillance guidelines, protocols and relevant documents; conducting self-administered, anonymous surveys with 286 local China CDC staff; and carrying out field observations in 32 sentinel sites in four provinces.Results: China has built an extensive HSS with 1888 sentinel sites to monitor HIV epidemic trends by population groups over time. The strengths of HSS lie in its flexibility, simplicity, usefulness and increase in coverage in locations and populations. With its rapid expansion in 2010, HSS faces challenges in maintaining acceptability, timeliness, data quality, representativeness and sustainability.Recommendations: Implementation of the national guidelines should be standardized by strengthening training, monitoring and supervision of all staff involved, including community-based organizations. National surveillance guidelines need to be revised to strengthen data quality and representativeness, particularly to include specific instructions on HIV testing result provision, collection of identifying information, sample size and sampling methods particularly for men who have sex with men (MSM, collection of refusal information, and data interpretation. Sustainability of China’s HSS could be strengthened by applying locally tailored surveillance strategies, strengthening coordination and cooperation among government agencies and ensuring financial and human resources.

  19. R and D study on on-line criticality surveillance system (V)

    International Nuclear Information System (INIS)

    Yamada, Sumasu

    2001-02-01

    In view of necessity and importance of criticality surveillance systems for ensuring the safety of nuclear fuel manufacturing and reprocessing plants, 5-year basic studies and 4 year R and D studies on an on-line criticality surveillance system were carried out since 1991. This report is a summary of these series of studies. Noticing that the signal from a neutron detector is random in principle, these series of studies aimed to accumulate knowledge for developing an inexpensive criticality surveillance system with quick response based on the Auto-Regressive Moving Average (ARMA) model identification algorithm. During five-year basic studies on criticality surveillance system since 1991, we obtained knowledge required for developing a criticality surveillance system based on the ARMA model identification algorithm through 1) studies on recursive ARMA model identification algorithms most appropriate for estimating subcriticality form time series data under a steady state condition, 2) studies on pre-processing of signal from neutron detectors, 3) developing a new recursive ARMA model identification algorithm with small time delay to estimate time-dependent subcriticality, 4) proposing a basic concept for the elements required for an on-line criticality surveillance system, and 5) numerical analysis of data from the DCA experiments. During next four-year R and D studies on a criticality surveillance system since 1996, we 1) proposed modules required for a no-line criticality surveillance system, 2) revealed effectiveness of a adaptive digital filter (ADF) algorithm, as an important redundancy to the recursive ARMA model identification algorithm to be used in the signal processing module through numerical analysis of real data, 3) proposed a module of the Feynman-α method over γ ray signal and a fast signal processing module for γ ray signal, 4) developed a line-noise removal filter(Notch filter) and revealed its effectiveness for the DCA data corrupted with power

  20. Surveillance system for nuclear power plants

    International Nuclear Information System (INIS)

    Mizeracki, M.T.

    1981-01-01

    This paper describes an integrated surveillance system for nuclear power plant application. The author explores an expanded role for closed circuit television, with remotely located cameras and infrared scanners as the basic elements. The video system, integrated with voice communication, can enhance the safe and efficient operation of the plant, by improving the operator's knowledge of plant conditions. 7 refs

  1. Real Time Wide Area Radiation Surveillance System

    Science.gov (United States)

    Biafore, M.

    2012-04-01

    We present the REWARD project, financed within the FP7 programme, theme SEC-2011.1.5-1 (Development of detection capabilities of difficult to detect radioactive sources and nuclear materials - Capability Project). Within this project, we propose a novel mobile system for real time, wide area radiation surveillance. The system is based on the integration of new miniaturized solid-state radiation sensors: a CdZnTe detector for gamma radiation and a high efficiency neutron detector based on novel silicon technologies. The sensing unit will include a wireless communication interface to send the data remotely to a monitoring base station which also uses a GPS system to calculate the position of the tag. The system will also incorporate middleware and high level software to provide web-service interfaces for the exchange of information, and that will offer top level functionalities as management of users, mobile tags and environment data and alarms, database storage and management and a web-based graphical user interface. Effort will be spent to ensure that the software is modular and re-usable across as many architectural levels as possible. Finally, an expert system will continuously analyze the information from the radiation sensor and correlate it with historical data from the tag location in order to generate an alarm when an abnormal situation is detected. The system will be useful for many different scenarios, including such lost radioactive sources and radioactive contamination. It will be possible to deploy in emergency units and in general in any type of mobile or static equipment. The sensing units will be highly portable thanks to their low size and low energy consumption. The complete system will be scalable in terms of complexity and cost and will offer very high precision on both the measurement and the location of the radiation. The modularity and flexibility of the system will allow for a realistic introduction to the market. Authorities may start with a

  2. Inexpensive remote video surveillance system with microcomputer and solar cells

    International Nuclear Information System (INIS)

    Guevara Betancourt, Edder

    2013-01-01

    A low-cost prototype is developed with a RPI plate for remote video surveillance. Additionally, the theoretical basis to provide energy independence have developed through solar cells and a battery bank. Some existing commercial monitoring systems are studied and analyzed, components such as: cameras, communication devices (WiFi and 3G), free software packages for video surveillance, control mechanisms and theory remote photovoltaic systems. A number of steps are developed to implement the module and install, configure and test each of the elements of hardware and software that make up the module, exploring the feasibility of providing intelligence to the system using the software chosen. Events that have been generated by motion detection have been simple, intuitive way to view, archive and extract. The implementation of the module by a microcomputer video surveillance and motion detection software (Zoneminder) has been an option for a lot of potential; as the platform for monitoring and recording data has provided all the tools to make a robust and secure surveillance. (author) [es

  3. Success Factors of European Syndromic Surveillance Systems: A Worked Example of Applying Qualitative Comparative Analysis.

    Science.gov (United States)

    Ziemann, Alexandra; Fouillet, Anne; Brand, Helmut; Krafft, Thomas

    2016-01-01

    Syndromic surveillance aims at augmenting traditional public health surveillance with timely information. To gain a head start, it mainly analyses existing data such as from web searches or patient records. Despite the setup of many syndromic surveillance systems, there is still much doubt about the benefit of the approach. There are diverse interactions between performance indicators such as timeliness and various system characteristics. This makes the performance assessment of syndromic surveillance systems a complex endeavour. We assessed if the comparison of several syndromic surveillance systems through Qualitative Comparative Analysis helps to evaluate performance and identify key success factors. We compiled case-based, mixed data on performance and characteristics of 19 syndromic surveillance systems in Europe from scientific and grey literature and from site visits. We identified success factors by applying crisp-set Qualitative Comparative Analysis. We focused on two main areas of syndromic surveillance application: seasonal influenza surveillance and situational awareness during different types of potentially health threatening events. We found that syndromic surveillance systems might detect the onset or peak of seasonal influenza earlier if they analyse non-clinical data sources. Timely situational awareness during different types of events is supported by an automated syndromic surveillance system capable of analysing multiple syndromes. To our surprise, the analysis of multiple data sources was no key success factor for situational awareness. We suggest to consider these key success factors when designing or further developing syndromic surveillance systems. Qualitative Comparative Analysis helped interpreting complex, mixed data on small-N cases and resulted in concrete and practically relevant findings.

  4. Comparing national infectious disease surveillance systems: China and the Netherlands.

    NARCIS (Netherlands)

    Vlieg, Willemijn L; Fanoy, Ewout B; van Asten, Liselotte; Liu, Xiaobo; Yang, Jun; Pilot, Eva; Bijkerk, Paul; van der Hoek, Wim; Krafft, Thomas; van der Sande, Marianne A; Liu, Qi-Yong

    2017-01-01

    Risk assessment and early warning (RAEW) are essential components of any infectious disease surveillance system. In light of the International Health Regulations (IHR)(2005), this study compares the organisation of RAEW in China and the Netherlands. The respective approaches towards surveillance of

  5. Optimization of station battery replacement

    International Nuclear Information System (INIS)

    Jancauskas, J.R.; Shook, D.A.

    1994-01-01

    During a loss of ac power at a nuclear generating station (including diesel generators), batteries provide the source of power which is required to operate safety-related components. Because traditional lead-acid batteries have a qualified life of 20 years, the batteries must be replaced a minimum of once during a station's lifetime, twice if license extension is pursued, and more often depending on actual in-service dates and the results of surveillance tests. Replacement of batteries often occurs prior to 20 years as a result of systems changes caused by factors such as Station Blackout Regulations, control system upgrades, incremental load growth, and changes in the operating times of existing equipment. Many of these replacement decisions are based on the predictive capabilities of manual design basis calculations. The inherent conservatism of manual calculations may result in battery replacements occurring before actually required. Computerized analysis of batteries can aid in optimizing the timing of replacements as well as in interpreting service test data. Computerized analysis also provides large benefits in maintaining the as-configured load profile and corresponding design margins, while also providing the capability of quickly analyze proposed modifications and response to internal and external audits

  6. Evaluation of the influenza sentinel surveillance system in Madagascar, 2009-2014.

    Science.gov (United States)

    Rakotoarisoa, Alain; Randrianasolo, Laurence; Tempia, Stefano; Guillebaud, Julia; Razanajatovo, Norosoa; Randriamampionona, Lea; Piola, Patrice; Halm, Ariane; Heraud, Jean-Michel

    2017-05-01

    Evaluation of influenza surveillance systems is poor, especially in Africa. In 2007, the Institut Pasteur de Madagascar and the Malagasy Ministry of Public Health implemented a countrywide system for the prospective syndromic and virological surveillance of influenza-like illnesses. In assessing this system's performance, we identified gaps and ways to promote the best use of resources. We investigated acceptability, data quality, flexibility, representativeness, simplicity, stability, timeliness and usefulness and developed qualitative and/or quantitative indicators for each of these attributes. Until 2007, the influenza surveillance system in Madagascar was only operational in Antananarivo and the observations made could not be extrapolated to the entire country. By 2014, the system covered 34 sentinel sites across the country. At 12 sites, nasopharyngeal and/or oropharyngeal samples were collected and tested for influenza virus. Between 2009 and 2014, 177 718 fever cases were detected, 25 809 (14.5%) of these fever cases were classified as cases of influenza-like illness. Of the 9192 samples from patients with influenza-like illness that were tested for influenza viruses, 3573 (38.9%) tested positive. Data quality for all evaluated indicators was categorized as above 90% and the system also appeared to be strong in terms of its acceptability, simplicity and stability. However, sample collection needed improvement. The influenza surveillance system in Madagascar performed well and provided reliable and timely data for public health interventions. Given its flexibility and overall moderate cost, this system may become a useful platform for syndromic and laboratory-based surveillance in other low-resource settings.

  7. Applied learning-based color tone mapping for face recognition in video surveillance system

    Science.gov (United States)

    Yew, Chuu Tian; Suandi, Shahrel Azmin

    2012-04-01

    In this paper, we present an applied learning-based color tone mapping technique for video surveillance system. This technique can be applied onto both color and grayscale surveillance images. The basic idea is to learn the color or intensity statistics from a training dataset of photorealistic images of the candidates appeared in the surveillance images, and remap the color or intensity of the input image so that the color or intensity statistics match those in the training dataset. It is well known that the difference in commercial surveillance cameras models, and signal processing chipsets used by different manufacturers will cause the color and intensity of the images to differ from one another, thus creating additional challenges for face recognition in video surveillance system. Using Multi-Class Support Vector Machines as the classifier on a publicly available video surveillance camera database, namely SCface database, this approach is validated and compared to the results of using holistic approach on grayscale images. The results show that this technique is suitable to improve the color or intensity quality of video surveillance system for face recognition.

  8. ISS--an electronic syndromic surveillance system for infectious disease in rural China.

    Directory of Open Access Journals (Sweden)

    Weirong Yan

    Full Text Available BACKGROUND: Syndromic surveillance system has great advantages in promoting the early detection of epidemics and reducing the necessities of disease confirmation, and it is especially effective for surveillance in resource poor settings. However, most current syndromic surveillance systems are established in developed countries, and there are very few reports on the development of an electronic syndromic surveillance system in resource-constrained settings. OBJECTIVE: This study describes the design and pilot implementation of an electronic surveillance system (ISS for the early detection of infectious disease epidemics in rural China, complementing the conventional case report surveillance system. METHODS: ISS was developed based on an existing platform 'Crisis Information Sharing Platform' (CRISP, combining with modern communication and GIS technology. ISS has four interconnected functions: 1 work group and communication group; 2 data source and collection; 3 data visualization; and 4 outbreak detection and alerting. RESULTS: As of Jan. 31(st 2012, ISS has been installed and pilot tested for six months in four counties in rural China. 95 health facilities, 14 pharmacies and 24 primary schools participated in the pilot study, entering respectively 74,256, 79,701, and 2330 daily records into the central database. More than 90% of surveillance units at the study sites are able to send daily information into the system. In the paper, we also presented the pilot data from health facilities in the two counties, which showed the ISS system had the potential to identify the change of disease patterns at the community level. CONCLUSIONS: The ISS platform may facilitate the early detection of infectious disease epidemic as it provides near real-time syndromic data collection, interactive visualization, and automated aberration detection. However, several constraints and challenges were encountered during the pilot implementation of ISS in rural China.

  9. Redefining syndromic surveillance

    Directory of Open Access Journals (Sweden)

    Rebecca Katz

    2011-12-01

    Full Text Available With growing concerns about international spread of disease and expanding use of early disease detection surveillance methods, the field of syndromic surveillance has received increased attention over the last decade. The purpose of this article is to clarify the various meanings that have been assigned to the term syndromic surveillance and to propose a refined categorization of the characteristics of these systems. Existing literature and conference proceedings were examined on syndromic surveillance from 1998 to 2010, focusing on low- and middle-income settings. Based on the 36 unique definitions of syndromic surveillance found in the literature, five commonly accepted principles of syndromic surveillance systems were identified, as well as two fundamental categories: specific and non-specific disease detection. Ultimately, the proposed categorization of syndromic surveillance distinguishes between systems that focus on detecting defined syndromes or outcomes of interest and those that aim to uncover non-specific trends that suggest an outbreak may be occurring. By providing an accurate and comprehensive picture of this field’s capabilities, and differentiating among system types, a unified understanding of the syndromic surveillance field can be developed, encouraging the adoption, investment in, and implementation of these systems in settings that need bolstered surveillance capacity, particularly low- and middle-income countries.

  10. SOA-surveillance Nederland

    NARCIS (Netherlands)

    Rijlaarsdam J; Bosman A; Laar MJW van de; CIE

    2000-01-01

    In May 1999 a working group was started to evaluate the current surveillance systems for sexually transmitted diseases (STD) and to make suggestions for a renewed effective and efficient STD surveillance system in the Netherlands. The surveillance system has to provide insight into the prevalence

  11. Space station operating system study

    Science.gov (United States)

    Horn, Albert E.; Harwell, Morris C.

    1988-01-01

    The current phase of the Space Station Operating System study is based on the analysis, evaluation, and comparison of the operating systems implemented on the computer systems and workstations in the software development laboratory. Primary emphasis has been placed on the DEC MicroVMS operating system as implemented on the MicroVax II computer, with comparative analysis of the SUN UNIX system on the SUN 3/260 workstation computer, and to a limited extent, the IBM PC/AT microcomputer running PC-DOS. Some benchmark development and testing was also done for the Motorola MC68010 (VM03 system) before the system was taken from the laboratory. These systems were studied with the objective of determining their capability to support Space Station software development requirements, specifically for multi-tasking and real-time applications. The methodology utilized consisted of development, execution, and analysis of benchmark programs and test software, and the experimentation and analysis of specific features of the system or compilers in the study.

  12. Sizewell B Power Station control dosimetry system

    International Nuclear Information System (INIS)

    Renn, G.

    1995-01-01

    Sizewell B Power Station is the first Pressurized Water Reactor (PWR) built in the UK for commercial electricity production. An effective control dosimetry system is a crucial tool, in allowing the station to assess its radiological performance against targets. This paper gives an overview of the control dosimetry system at Sizewell B and describes early operating experience with the system. (UK)

  13. SCORPIO-VVER core monitoring and surveillance system with advanced capabilities

    International Nuclear Information System (INIS)

    Molnar, J.; Vocka, R.

    2010-01-01

    In this work authors present 12 years of operation experience of core monitoring and surveillance system with advanced capabilities on nuclear power plants on 6 unit of VVER-440 type of reactors at two different NPPs. The original version of the SCORPIO (Surveillance of reactor CORe by PIcture On-line display) system was developed for the western type of PWR reactors. The first version of the SCORPIO-VVER Core Monitoring System for Dukovany NPP (VVER-440 type of reactor, Czech Republic) was developed in 1998. For SCORPIO-VVER implementation at Bohunice NPP in Slovakia (2001) the system was enhanced with startup module KRITEX.

  14. Man-systems distributed system for Space Station Freedom

    Science.gov (United States)

    Lewis, J. L.

    1990-01-01

    Viewgraphs on man-systems distributed system for Space Station Freedom are presented. Topics addressed include: description of man-systems (definition, requirements, scope, subsystems, and topologies); implementation (approach, tools); man-systems interfaces (system to element and system to system); prime/supporting development relationship; selected accomplishments; and technical challenges.

  15. Was the French clinical surveillance system of bovine brucellosis influenced by the occurrence and surveillance of other abortive diseases?

    Science.gov (United States)

    Bronner, Anne; Morignat, Eric; Touratier, Anne; Gache, Kristel; Sala, Carole; Calavas, Didier

    2015-03-01

    The bovine brucellosis clinical surveillance system implemented in France aims to detect early any case of bovine brucellosis, a disease of which the country has been declared free since 2005. It relies on the mandatory notification of every bovine abortion. Following the spread of the Schmallenberg virus (SBV) in France in 2012 and 2013, and the implementation in 2012 of a clinical surveillance programme of Q fever based on abortion notifications in ten pilot départements, our objective was to study whether these two events influenced the brucellosis clinical surveillance system. The proportion of notifying farmers was analyzed over each semester from June 1, 2009 to June 30, 2013 according to the size and production type of herds, SBV status of départements and the implementation of the Q fever surveillance. Our analysis showed a slight increase in the proportion of notifying farmers as départements became infected by SBV, and after the implementation of Q fever surveillance (during the first semester of 2013). These variations might be explained by an increase in abortion occurrence (congenital deformities in newborns, due to SBV) and/or by an increase in farmers' and veterinarians' awareness (due to the spread of SBV and the implementation of the Q fever surveillance). These results highlight the difficulties in interpreting variations in the proportion of notifying farmers as a consequence of an increase in abortion occurrence. As bovine abortion surveillance can play an important role in the early warning for several diseases, there is a need to explore other ways to monitor abortions in cattle, such as syndromic surveillance using the dates of artificial insemination or calving data. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Plant computer system in nuclear power station

    International Nuclear Information System (INIS)

    Kato, Shinji; Fukuchi, Hiroshi

    1991-01-01

    In nuclear power stations, centrally concentrated monitoring system has been adopted, and in central control rooms, large quantity of information and operational equipments concentrate, therefore, those become the important place of communication between plants and operators. Further recently, due to the increase of the unit capacity, the strengthening of safety, the problems of man-machine interface and so on, it has become important to concentrate information, to automate machinery and equipment and to simplify them for improving the operational environment, reliability and so on. On the relation of nuclear power stations and computer system, to which attention has been paid recently as the man-machine interface, the example in Tsuruga Power Station, Japan Atomic Power Co. is shown. No.2 plant in the Tsuruga Power Station is a PWR plant with 1160 MWe output, which is a home built standardized plant, accordingly the computer system adopted here is explained. The fundamental concept of the central control board, the process computer system, the design policy, basic system configuration, reliability and maintenance, CRT display, and the computer system for No.1 BWR 357 MW plant are reported. (K.I.)

  17. Automated Safety Incident Surveillance and Tracking System (ASISTS)

    Data.gov (United States)

    Department of Veterans Affairs — The Automated Safety Incident Surveillance and Tracking System (ASISTS) is a repository of Veterans Health Administration (VHA) employee accident data. Many types of...

  18. Infectious Disease Surveillance in the Big Data Era: Towards Faster and Locally Relevant Systems

    Science.gov (United States)

    Simonsen, Lone; Gog, Julia R.; Olson, Don; Viboud, Cécile

    2016-01-01

    While big data have proven immensely useful in fields such as marketing and earth sciences, public health is still relying on more traditional surveillance systems and awaiting the fruits of a big data revolution. A new generation of big data surveillance systems is needed to achieve rapid, flexible, and local tracking of infectious diseases, especially for emerging pathogens. In this opinion piece, we reflect on the long and distinguished history of disease surveillance and discuss recent developments related to use of big data. We start with a brief review of traditional systems relying on clinical and laboratory reports. We then examine how large-volume medical claims data can, with great spatiotemporal resolution, help elucidate local disease patterns. Finally, we review efforts to develop surveillance systems based on digital and social data streams, including the recent rise and fall of Google Flu Trends. We conclude by advocating for increased use of hybrid systems combining information from traditional surveillance and big data sources, which seems the most promising option moving forward. Throughout the article, we use influenza as an exemplar of an emerging and reemerging infection which has traditionally been considered a model system for surveillance and modeling. PMID:28830112

  19. Introduction to surveillance studies

    CERN Document Server

    Petersen, JK

    2012-01-01

    Introduction & OverviewIntroduction Brief History of Surveillance Technologies & TechniquesOptical SurveillanceAerial Surveillance Audio Surveillance Radio-Wave SurveillanceGlobal Positioning Systems Sensors Computers & the Internet Data Cards Biochemical Surveillance Animal Surveillance Biometrics Genetics Practical ConsiderationsPrevalence of Surveillance Effectiveness of Surveillance Freedom & Privacy IssuesConstitutional Freedoms Privacy Safeguards & Intrusions ResourcesReferences Glossary Index

  20. Sensitivity of the Dengue Surveillance System in Brazil for Detecting Hospitalized Cases

    Science.gov (United States)

    2016-01-01

    We evaluated the sensitivity of the dengue surveillance system in detecting hospitalized cases in ten capital cities in Brazil from 2008 to 2013 using a probabilistic record linkage of two independent information systems hospitalization (SIH-SUS) adopted as the gold standard and surveillance (SINAN). Sensitivity was defined as the proportion of cases reported to the surveillance system amid the suspected hospitalized cases registered in SIH-SUS. Of the 48,174 hospitalizations registered in SIH-SUS, 24,469 (50.7%) were reported and registered in SINAN, indicating an overall sensitivity of 50.8% (95%CI 50.3–51.2). The observed sensitivity for each of the municipalities included in the study ranged from 22.0% to 99.1%. The combination of the two data sources identified 71,161 hospitalizations, an increase of 97.0% over SINAN itself. Our results allowed establishing the proportion of underreported dengue hospitalizations in the public health system in Brazil, highlighting the use of probabilistic record linkage as a valuable tool for evaluating surveillance systems. PMID:27192405

  1. A review of occupational disease surveillance systems in Modernet countries.

    Science.gov (United States)

    Carder, M; Bensefa-Colas, L; Mattioli, S; Noone, P; Stikova, E; Valenty, M; Telle-Lamberton, M

    2015-11-01

    To improve occupational health public policies and to facilitate coordinated research within the European Union to reduce the incidence of occupational diseases (ODs), it is important to know what OD surveillance systems exist and how they compare. Monitoring trends in occupational diseases and tracing new and emerging risks in a network (Modernet) participants are well placed to provide this information as most either contribute data to and/or are involved in the management of OD systems. To identify and describe OD surveillance systems in Modernet countries with the longer-term objective of identifying a core template to be used on a large scale. A questionnaire sent to Modernet participants, seeking structured information about the OD surveillance system(s) in their country. Overall 14 countries (70%) provided information for 33 OD systems, among them 11 compensation-based (CB) systems. Six countries provided information for non-CB systems reporting for any type of OD. The other systems reported either only ODs from a prescribed list, or specific diagnoses or diagnostic groups, with reports to most schemes being physician-based. Data collected varied but all systems collected diagnosis, age, gender, date reported and occupation (and/or industry) and most collected information on exposure. This review provides information beneficial to both policy makers and researchers by identifying data sources useable to measure OD trends in European countries and opening the way to future work, both on trend comparisons within Europe and on the definition of a core template to extend OD surveillance on a larger scale. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. CPSC’s National Electronic Injury Surveillance System (NEISS)

    Data.gov (United States)

    US Consumer Product Safety Commission — CPSC’s National Electronic Injury Surveillance System (NEISS) is a national probability sample of hospitals in the U.S. and its territories. Patient information is...

  3. Formal and informal surveillance systems: how to build links

    Directory of Open Access Journals (Sweden)

    S. Desvaux

    2015-11-01

    Full Text Available Within the framework of highly pathogenic avian influenza (HPAI surveillance in Vietnam, interviews were carried out with poultry farmers and local animal health operators in two municipalities of the Red River delta with a view to documenting the circulation of health information concerning poultry (content of the information; method, scope and speed of circulation; actors involved; actions triggered as a result of the information received; economic and social incentives for disseminating or withholding information. The main results show that (i active informal surveillance networks exist, (ii the alert levels vary and the measures applied by the poultry farmers are myriad and often far-removed from the official recommendations, and (iii the municipal veterinarian is at the interface between the formal and the informal surveillance systems. The conclusions emphasize the need for the authorities to separate distinctly surveillance and control activities, and to regionalize control strategies, taking into account epidemiological specificities and social dynamics at local level.

  4. Behavioral Risk Factor Surveillance System (BRFSS) Historical Questions

    Data.gov (United States)

    U.S. Department of Health & Human Services — 1984-2016. Centers for Disease Control and Prevention (CDC). BRFSS Survey Data. The BRFSS is a continuous, state-based surveillance system that collects information...

  5. Designing a Low-Resolution Face Recognition System for Long-Range Surveillance

    NARCIS (Netherlands)

    Peng, Y.; Spreeuwers, Lieuwe Jan; Veldhuis, Raymond N.J.

    2016-01-01

    Most face recognition systems deal well with high-resolution facial images, but perform much worse on low-resolution facial images. In low-resolution face recognition, there is a specific but realistic surveillance scenario: a surveillance camera monitoring a large area. In this scenario, usually

  6. Testing a symptom-based surveillance system at high-profile gatherings as a preparatory measure for bioterrorism.

    Science.gov (United States)

    Osaka, K; Takahashi, H; Ohyama, T

    2002-12-01

    We tested symptom-based surveillance during the G8 conference in 2000 as a means of detecting outbreaks, including bio-terrorism attacks, promptly. Five categories of symptoms (skin and haemorrhagic, respiratory, gastrointestinal, neurological and unexplained) were adopted for the case definition of the surveillance. The surveillance began I week before the conference, and continued until 1 week after the conference ended. We could not detect any outbreaks during this surveillance. Compared to the existing diagnosis-based surveillance system, symptom-based surveillance has the advantages of timeliness and simplicity. However, poor specificity and difficulties in determining epidemic threshold were important limitations of this system. To increase the specificity of surveillance, it is essential to incorporate rapid laboratory diagnoses into the system.

  7. FPGA-Based Real-Time Motion Detection for Automated Video Surveillance Systems

    Directory of Open Access Journals (Sweden)

    Sanjay Singh

    2016-03-01

    Full Text Available Design of automated video surveillance systems is one of the exigent missions in computer vision community because of their ability to automatically select frames of interest in incoming video streams based on motion detection. This research paper focuses on the real-time hardware implementation of a motion detection algorithm for such vision based automated surveillance systems. A dedicated VLSI architecture has been proposed and designed for clustering-based motion detection scheme. The working prototype of a complete standalone automated video surveillance system, including input camera interface, designed motion detection VLSI architecture, and output display interface, with real-time relevant motion detection capabilities, has been implemented on Xilinx ML510 (Virtex-5 FX130T FPGA platform. The prototyped system robustly detects the relevant motion in real-time in live PAL (720 × 576 resolution video streams directly coming from the camera.

  8. Food and water radioactivity surveillance system in Romania

    International Nuclear Information System (INIS)

    Cucu, A.; Gheorghe, R.; May, C.; Barbu, R.

    2008-01-01

    Full text: Justification: Food and water radioactivity content are closely related both to natural radioactivity and also generated by contamination due to anthropic nuclear activities. Consequently, in accordance with the European Union acquis and World Health Organization recommendation, surveillance systems were operationalized in many European countries. According to the national Romanian derived legislation the public health authorities are responsible for organizing and coordination of the national surveillance system for water and food radioactivity and their health related effects. Objectives: Description of the levels and type of radioactivity of drinking water and main foodstuffs and their contribution to the Romanian population exposure in order to elaborate appropriate public health interventions. Method: The gross parameters, alpha and beta, have been used for screening surveillance of drinking water sources indeed for potable purposes in order to identify those that could exceed the total indicative dose of 0.1 mSv/year. The food surveillance was focused on the main foodstuffs including milk, meat, fish, eggs, bread, potatoes, root vegetables (mainly carrots), leafy vegetables (mainly cabbage), fruits, and canteen menu, controlled for presence and level of radioactivity for 137 Cs, 90 Sr, 226 Ra, 210 Po and 40 K. Nuclear facility related monitoring for areas as nuclear power plant Cernavoda (type HWR-CANDU) and for regions with activities of extraction and fabrication of uranium fuel includes monitoring of radioactivity for: environmental deposit levels, surface waters, spontaneous vegetation, drinking water and foodstuffs. Results: 1) The water radioactivity surveillance results, mapped by administrative borders of the national territory, reveal that parameters of drinking water complies both with Drinking Water Directive 98/83 EC and WHO recommandation/2004; 2) For food stuff radioactivity: a) Mean registered values fully comply with reference for

  9. Evaluation of an Electronic Smart-Card Based School Absenteeism Surveillance System

    OpenAIRE

    So, HC; Lam, CK; Tam, YH; Cowling, BJ; Leung, GM; Lau, EHY; Ip, DKM

    2014-01-01

    We evaluated the performance of an electronic smart-card based school absenteeism surveillance system which was initiated in 2008 in Hong Kong. The result demonstrated the feasibility and potential benefit of employing electronic school absenteeism data as captured automatically by a smart card system as an alternative data stream for monitoring influenza activities, and flexibility in establishing surveillance for emerging diseases. The increasing popularity of usage of smart card technology...

  10. Cost analysis of an integrated vaccine-preventable disease surveillance system in Costa Rica.

    Science.gov (United States)

    Toscano, C M; Vijayaraghavan, M; Salazar-Bolaños, H M; Bolaños-Acuña, H M; Ruiz-González, A I; Barrantes-Solis, T; Fernández-Vargas, I; Panero, M S; de Oliveira, L H; Hyde, T B

    2013-07-02

    Following World Health Organization recommendations set forth in the Global Framework for Immunization Monitoring and Surveillance, Costa Rica in 2009 became the first country to implement integrated vaccine-preventable disease (iVPD) surveillance, with support from the U.S. Centers for Disease Control and Prevention (CDC) and the Pan American Health Organization (PAHO). As surveillance for diseases prevented by new vaccines is integrated into existing surveillance systems, these systems could cost more than routine surveillance for VPDs targeted by the Expanded Program on Immunization. We estimate the costs associated with establishing and subsequently operating the iVPD surveillance system at a pilot site in Costa Rica. We retrospectively collected data on costs incurred by the institutions supporting iVPD surveillance during the preparatory (January 2007 through August 2009) and implementation (September 2009 through August 2010) phases of the iVPD surveillance project in Costa Rica. These data were used to estimate costs for personnel, meetings, infrastructure, office equipment and supplies, transportation, and laboratory facilities. Costs incurred by each of the collaborating institutions were also estimated. During the preparatory phase, the estimated total cost was 128,000 U.S. dollars (US$), including 64% for personnel costs. The preparatory phase was supported by CDC and PAHO. The estimated cost for 1 year of implementation was US$ 420,000, including 58% for personnel costs, 28% for laboratory costs, and 14% for meeting, infrastructure, office, and transportation costs combined. The national reference laboratory and the PAHO Costa Rica office incurred 64% of total costs, and other local institutions supporting iVPD surveillance incurred the remaining 36%. Countries planning to implement iVPD surveillance will require adequate investments in human resources, laboratories, data management, reporting, and investigation. Our findings will be valuable for

  11. The Argentine remote monitoring and surveillance system

    International Nuclear Information System (INIS)

    Bonino, A.; Roca, J.L.; Perez, A.; Pizarro, L.; Krimer, M.; Teira, R.; Higa, Z.; Saettone, S.; Monzon, J.; Moroni, D.

    1996-01-01

    The Scientific and Technical Support Department of the Argentine National Board of Nuclear Regulation (ENREN) has developed a Remote Monitoring and Surveillance System (RMSS) that provides a media to verify state of variables related to the monitoring and surveillance activities of nuclear facilities, mainly safeguard applications. RMSS includes a variety of on site installed sensors, an authenticated radiofrequency communication link, a receiver processing unit, an active vision set and a user friendly personal computer interface to collect, view and store pertinent histories of events. A real time data base allows consulting, maintenance, updating and checking activities. RMSS could be integrated into a LAN or WAN via modem for use in a remote operation scheme. In this paper a description of the RMSS is provided. Also, an overview of the RMSS operation at one facility under safeguards belonging to the National Commission of Atomic Energy (CNEA) is presented. Results and conclusions of the system associated with this facility are given. (author). 37 figs

  12. The Argentine remote monitoring and surveillance system

    Energy Technology Data Exchange (ETDEWEB)

    Bonino, A; Roca, J L; Perez, A; Pizarro, L; Krimer, M; Teira, R; Higa, Z; Saettone, S; Monzon, J; Moroni, D [Ente Nacional Regulador Nuclear, Buenos Aires (Argentina). Dept. Apoyo Cientifico y Tecnico

    1997-12-31

    The Scientific and Technical Support Department of the Argentine National Board of Nuclear Regulation (ENREN) has developed a Remote Monitoring and Surveillance System (RMSS) that provides a media to verify state of variables related to the monitoring and surveillance activities of nuclear facilities, mainly safeguard applications. RMSS includes a variety of on site installed sensors, an authenticated radiofrequency communication link, a receiver processing unit, an active vision set and a user friendly personal computer interface to collect, view and store pertinent histories of events. A real time data base allows consulting, maintenance, updating and checking activities. RMSS could be integrated into a LAN or WAN via modem for use in a remote operation scheme. In this paper a description of the RMSS is provided. Also, an overview of the RMSS operation at one facility under safeguards belonging to the National Commission of Atomic Energy (CNEA) is presented. Results and conclusions of the system associated with this facility are given. (author). 37 figs.

  13. Real-time tracking and fast retrieval of persons in multiple surveillance cameras of a shopping mall

    NARCIS (Netherlands)

    Bouma, H.; Baan, J.; Landsmeer, S.; Kruszynski, K.J.; Antwerpen, G. van; Dijk, J.

    2013-01-01

    The capability to track individuals in CCTV cameras is important for e.g. surveillance applications at large areas such as train stations, airports and shopping centers. However, it is laborious to track and trace people over multiple cameras. In this paper, we present a system for real-time

  14. Evaluation of Syndromic Surveillance Systems in 6 US State and Local Health Departments.

    Science.gov (United States)

    Thomas, Mathew J; Yoon, Paula W; Collins, James M; Davidson, Arthur J; Mac Kenzie, William R

    Evaluating public health surveillance systems is critical to ensuring that conditions of public health importance are appropriately monitored. Our objectives were to qualitatively evaluate 6 state and local health departments that were early adopters of syndromic surveillance in order to (1) understand the characteristics and current uses, (2) identify the most and least useful syndromes to monitor, (3) gauge the utility for early warning and outbreak detection, and (4) assess how syndromic surveillance impacted their daily decision making. We adapted evaluation guidelines from the Centers for Disease Control and Prevention and gathered input from the Centers for Disease Control and Prevention subject matter experts in public health surveillance to develop a questionnaire. We interviewed staff members from a convenience sample of 6 local and state health departments with syndromic surveillance programs that had been in operation for more than 10 years. Three of the 6 interviewees provided an example of using syndromic surveillance to identify an outbreak (ie, cluster of foodborne illness in 1 jurisdiction) or detect a surge in cases for seasonal conditions (eg, influenza in 2 jurisdictions) prior to traditional, disease-specific systems. Although all interviewees noted that syndromic surveillance has not been routinely useful or efficient for early outbreak detection or case finding in their jurisdictions, all agreed that the information can be used to improve their understanding of dynamic disease control environments and conditions (eg, situational awareness) in their communities. In the jurisdictions studied, syndromic surveillance may be useful for monitoring the spread and intensity of large outbreaks of disease, especially influenza; enhancing public health awareness of mass gatherings and natural disasters; and assessing new, otherwise unmonitored conditions when real-time alternatives are unavailable. Future studies should explore opportunities to

  15. Real-time tracking and fast retrieval of persons in multiple surveillance cameras of a shopping mall

    Science.gov (United States)

    Bouma, Henri; Baan, Jan; Landsmeer, Sander; Kruszynski, Chris; van Antwerpen, Gert; Dijk, Judith

    2013-05-01

    The capability to track individuals in CCTV cameras is important for e.g. surveillance applications at large areas such as train stations, airports and shopping centers. However, it is laborious to track and trace people over multiple cameras. In this paper, we present a system for real-time tracking and fast interactive retrieval of persons in video streams from multiple static surveillance cameras. This system is demonstrated in a shopping mall, where the cameras are positioned without overlapping fields-of-view and have different lighting conditions. The results show that the system allows an operator to find the origin or destination of a person more efficiently. The misses are reduced with 37%, which is a significant improvement.

  16. Active surveillance for influenza vaccine adverse events: the integrated vaccine surveillance system.

    Science.gov (United States)

    Newes-Adeyi, Gabriella; Greece, Jacey; Bozeman, Sam; Walker, Deborah Klein; Lewis, Faith; Gidudu, Jane

    2012-02-01

    We conducted a pilot study of the Integrated Vaccine Surveillance System (IVSS), a novel active surveillance system for monitoring influenza vaccine adverse events that could be used in mass vaccination settings. We recruited 605 adult vaccinees from a convenience sample of 12 influenza vaccine clinics conducted by public health departments of two U.S. metropolitan regions. Vaccinees provided daily reports on adverse reactions following immunization (AEFI) using an interactive voice response system (IVR) or the internet for 14 consecutive days following immunization. Followup with nonrespondents was conducted through computer-assisted telephone interviewing (CATI). Data on vaccinee reports were available real-time through a dedicated secure website. 90% (545) of vaccinees made at least one daily report and 49% (299) reported consecutively for the full 14-day period. 58% (315) used internet, 20% (110) IVR, 6% (31) CATI, and 16% (89) used a combination for daily reports. Of the 545 reporters, 339 (62%) reported one or more AEFI, for a total of 594 AEFIs reported. The majority (505 or 85%) of these AEFIs were mild symptoms. It is feasible to develop a system to obtain real-time data on vaccine adverse events. Vaccinees are willing to provide daily reports for a considerable time post vaccination. Offering multiple modes of reporting encourages high response rates. Study findings on AEFIs showed that the IVSS was able to exhibit the emerging safety profile of the 2008 seasonal influenza vaccine. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Performance Assessment of a Communicable Disease Surveillance System in Response to the Twin Earthquakes of East Azerbaijan.

    Science.gov (United States)

    Babaie, Javad; Ardalan, Ali; Vatandoost, Hasan; Goya, Mohammad Mehdi; Akbari Sari, Ali

    2015-08-01

    Following the twin earthquakes on August 11, 2012, in the East Azerbaijan province of Iran, the provincial health center set up a surveillance system to monitor communicable diseases. This study aimed to assess the performance of this surveillance system. In this quantitative-qualitative study, performance of the communicable diseases surveillance system was assessed by using the updated guidelines of the Centers for Disease Control and Prevention (CDC). Qualitative data were collected through interviews with the surveillance system participants, and quantitative data were obtained from the surveillance system. The surveillance system was useful, simple, representative, timely, and flexible. The data quality, acceptability, and stability of the surveillance system were 65.6%, 10.63%, and 100%, respectively. The sensitivity and positive predictive value were not calculated owing to the absence of a gold standard. The surveillance system satisfactorily met the goals expected for its setup. The data obtained led to the control of communicable diseases in the affected areas. Required interventions based on the incidence of communicable disease were designed and implemented. The results also reassured health authorities and the public. However, data quality and acceptability should be taken into consideration and reviewed for implementation in future disasters.

  18. The modular integrated video system (MIVS)

    International Nuclear Information System (INIS)

    Schneider, S.L.; Sonnier, C.S.

    1987-01-01

    The Modular Integrated Video System (MIVS) is being developed for the International Atomic Energy Agency (IAEA) for use in facilities where mains power is available and the separation of the Camera and Recording Control Unit is desirable. The system is being developed under the US Program for Technical Assistance to the IAEA Safeguards (POTAS). The MIVS is designed to be a user-friendly system, allowing operation with minimal effort and training. The system software, through the use of a Liquid Crystal Display (LCD) and four soft keys, leads the inspector through the setup procedures to accomplish the intended surveillance or maintenance task. Review of surveillance data is accomplished with the use of a Portable Review Station. This Review Station will aid the inspector in the review process and determine the number of missed video scenes during a surveillance period

  19. Technical specifications: Hope Creek Generating Station (Docket No. 50-354). Appendix A to License No. NPF-50

    International Nuclear Information System (INIS)

    1986-04-01

    Information is provided on the technical specifications for the Hope Creek Nuclear Power Station. Areas of interest discussed in this report include: safety limits and limiting safety system settings; limiting conditions for operation and surveillance requirements; design features; and administrative controls

  20. Low-Cost National Media-Based Surveillance System for Public Health Events, Bangladesh

    Science.gov (United States)

    Ao, Trong T.; Rahman, Mahmudur; Haque, Farhana; Chakraborty, Apurba; Hossain, M. Jahangir; Haider, Sabbir; Alamgir, A.S.M.; Sobel, Jeremy; Luby, Stephen P.

    2016-01-01

    We assessed a media-based public health surveillance system in Bangladesh during 2010–2011. The system is a highly effective, low-cost, locally appropriate, and sustainable outbreak detection tool that could be used in other low-income, resource-poor settings to meet the capacity for surveillance outlined in the International Health Regulations 2005. PMID:26981877

  1. Characterization of airborne bacteria at an underground subway station.

    Science.gov (United States)

    Dybwad, Marius; Granum, Per Einar; Bruheim, Per; Blatny, Janet Martha

    2012-03-01

    The reliable detection of airborne biological threat agents depends on several factors, including the performance criteria of the detector and its operational environment. One step in improving the detector's performance is to increase our knowledge of the biological aerosol background in potential operational environments. Subway stations are enclosed public environments, which may be regarded as potential targets for incidents involving biological threat agents. In this study, the airborne bacterial community at a subway station in Norway was characterized (concentration level, diversity, and virulence- and survival-associated properties). In addition, a SASS 3100 high-volume air sampler and a matrix-assisted laser desorption ionization-time of flight mass spectrometry-based isolate screening procedure was used for these studies. The daytime level of airborne bacteria at the station was higher than the nighttime and outdoor levels, and the relative bacterial spore number was higher in outdoor air than at the station. The bacterial content, particle concentration, and size distribution were stable within each environment throughout the study (May to September 2010). The majority of the airborne bacteria belonged to the genera Bacillus, Micrococcus, and Staphylococcus, but a total of 37 different genera were identified in the air. These results suggest that anthropogenic sources are major contributors to airborne bacteria at subway stations and that such airborne communities could harbor virulence- and survival-associated properties of potential relevance for biological detection and surveillance, as well as for public health. Our findings also contribute to the development of realistic testing and evaluation schemes for biological detection/surveillance systems by providing information that can be used to mimic real-life operational airborne environments in controlled aerosol test chambers.

  2. Characterization of Airborne Bacteria at an Underground Subway Station

    Science.gov (United States)

    Dybwad, Marius; Granum, Per Einar; Bruheim, Per

    2012-01-01

    The reliable detection of airborne biological threat agents depends on several factors, including the performance criteria of the detector and its operational environment. One step in improving the detector's performance is to increase our knowledge of the biological aerosol background in potential operational environments. Subway stations are enclosed public environments, which may be regarded as potential targets for incidents involving biological threat agents. In this study, the airborne bacterial community at a subway station in Norway was characterized (concentration level, diversity, and virulence- and survival-associated properties). In addition, a SASS 3100 high-volume air sampler and a matrix-assisted laser desorption ionization–time of flight mass spectrometry-based isolate screening procedure was used for these studies. The daytime level of airborne bacteria at the station was higher than the nighttime and outdoor levels, and the relative bacterial spore number was higher in outdoor air than at the station. The bacterial content, particle concentration, and size distribution were stable within each environment throughout the study (May to September 2010). The majority of the airborne bacteria belonged to the genera Bacillus, Micrococcus, and Staphylococcus, but a total of 37 different genera were identified in the air. These results suggest that anthropogenic sources are major contributors to airborne bacteria at subway stations and that such airborne communities could harbor virulence- and survival-associated properties of potential relevance for biological detection and surveillance, as well as for public health. Our findings also contribute to the development of realistic testing and evaluation schemes for biological detection/surveillance systems by providing information that can be used to mimic real-life operational airborne environments in controlled aerosol test chambers. PMID:22247150

  3. Surveillance and Datalink Communication Performance Analysis for Distributed Separation Assurance System Architectures

    Science.gov (United States)

    Chung, William W.; Linse, Dennis J.; Alaverdi, Omeed; Ifarraguerri, Carlos; Seifert, Scott C.; Salvano, Dan; Calender, Dale

    2012-01-01

    This study investigates the effects of two technical enablers: Automatic Dependent Surveillance - Broadcast (ADS-B) and digital datalink communication, of the Federal Aviation Administration s Next Generation Air Transportation System (NextGen) under two separation assurance (SA) system architectures: ground-based SA and airborne SA, on overall separation assurance performance. Datalink performance such as successful reception probability in both surveillance and communication messages, and surveillance accuracy are examined in various operational conditions. Required SA performance is evaluated as a function of subsystem performance, using availability, continuity, and integrity metrics to establish overall required separation assurance performance, under normal and off-nominal conditions.

  4. Environmental radiation monitoring system in nuclear power station

    International Nuclear Information System (INIS)

    Matsuoka, Sadazumi; Tadachi, Katsuo; Endo, Mamoru; Yuya, Hiroshi

    1983-01-01

    At the time of the construction of nuclear power stations, prior to their start of operation, the state of environmental radiation must be grasped. After the start of the power stations, based on those data, the system of environmental radiation monitoring is established. Along with the construction of Kashiwazaki-Kariwa Nuclear Power Station, The Tokyo Electric Power Co., Inc. jointly with Fujitsu Ltd. has developed a high-reliability, environmental radiation monitoring system, and adopted ''optical data highways'' using optical fiber cables for communication. It consists of a central monitoring station and 11 telemeter observation points, for collecting both radiation and meteorological data. The data sent to the central station through the highways are then outputted on a monitoring panel. They are analyzed with a central processor, and the results are printed out. (Mori, K.)

  5. A video imaging system and related control hardware for nuclear safeguards surveillance applications

    International Nuclear Information System (INIS)

    Whichello, J.V.

    1987-03-01

    A novel video surveillance system has been developed for safeguards applications in nuclear installations. The hardware was tested at a small experimental enrichment facility located at the Lucas Heights Research Laboratories. The system uses digital video techniques to store, encode and transmit still television pictures over the public telephone network to a receiver located in the Australian Safeguards Office at Kings Cross, Sydney. A decoded, reconstructed picture is then obtained using a second video frame store. A computer-controlled video cassette recorder is used automatically to archive the surveillance pictures. The design of the surveillance system is described with examples of its operation

  6. Infectious Disease Surveillance in the Big Data Era: Towards Faster and Locally Relevant Systems.

    Science.gov (United States)

    Simonsen, Lone; Gog, Julia R; Olson, Don; Viboud, Cécile

    2016-12-01

    While big data have proven immensely useful in fields such as marketing and earth sciences, public health is still relying on more traditional surveillance systems and awaiting the fruits of a big data revolution. A new generation of big data surveillance systems is needed to achieve rapid, flexible, and local tracking of infectious diseases, especially for emerging pathogens. In this opinion piece, we reflect on the long and distinguished history of disease surveillance and discuss recent developments related to use of big data. We start with a brief review of traditional systems relying on clinical and laboratory reports. We then examine how large-volume medical claims data can, with great spatiotemporal resolution, help elucidate local disease patterns. Finally, we review efforts to develop surveillance systems based on digital and social data streams, including the recent rise and fall of Google Flu Trends. We conclude by advocating for increased use of hybrid systems combining information from traditional surveillance and big data sources, which seems the most promising option moving forward. Throughout the article, we use influenza as an exemplar of an emerging and reemerging infection which has traditionally been considered a model system for surveillance and modeling. Published by Oxford University Press for the Infectious Diseases Society of America 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  7. Environmental Radiation Surveillance Results from over the Last Decade of Operational Experience at the Regional Radiation Monitoring Stations(RRMS)

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hae Young [Daegu Regional Radiation Monitoring Station, Daegu (Korea, Republic of); Yoo, Dong Han [Ulsan Regional Radiation Monitoring Station, Ulsan (Korea, Republic of); Lee, Sang Hoon [Kyungpook National University, Daegu (Korea, Republic of)

    2015-10-15

    The objectives of the current program are to monitor environmental radiation/radioactivity level in Korea and to provide the base-line data on environmental radiation/radioactivity which will be useful in the case of radiological emergency situations. This program plays an important role in the view of protecting the public health against the potential hazards of radiation and maintaining a clean environment. This paper describes an introduction to the Regional Radiation Monitoring Stations (RRMS), and also presents some results of recent years (2001-2014). The environmental radiation surveillance results of years 2001-2014 have been described. It indicates normal levels of radiation in the past years. These kinds of studies are very important in providing references in understanding the environmental radioactivity level in a particular region.

  8. Evolutionary growth for Space Station Freedom electrical power system

    Science.gov (United States)

    Marshall, Matthew Fisk; Mclallin, Kerry; Zernic, Mike

    1989-01-01

    Over an operational lifetime of at least 30 yr, Space Station Freedom will encounter increased Space Station user requirements and advancing technologies. The Space Station electrical power system is designed with the flexibility to accommodate these emerging technologies and expert systems and is being designed with the necessary software hooks and hardware scars to accommodate increased growth demand. The electrical power system is planned to grow from the initial 75 kW up to 300 kW. The Phase 1 station will utilize photovoltaic arrays to produce the electrical power; however, for growth to 300 kW, solar dynamic power modules will be utilized. Pairs of 25 kW solar dynamic power modules will be added to the station to reach the power growth level. The addition of solar dynamic power in the growth phase places constraints in the initial Space Station systems such as guidance, navigation, and control, external thermal, truss structural stiffness, computational capabilities and storage, which must be planned-in, in order to facilitate the addition of the solar dynamic modules.

  9. Development of the Diabetes Technology Society Blood Glucose Monitor System Surveillance Protocol.

    Science.gov (United States)

    Klonoff, David C; Lias, Courtney; Beck, Stayce; Parkes, Joan Lee; Kovatchev, Boris; Vigersky, Robert A; Arreaza-Rubin, Guillermo; Burk, Robert D; Kowalski, Aaron; Little, Randie; Nichols, James; Petersen, Matt; Rawlings, Kelly; Sacks, David B; Sampson, Eric; Scott, Steve; Seley, Jane Jeffrie; Slingerland, Robbert; Vesper, Hubert W

    2016-05-01

    Inaccurate blood glucsoe monitoring systems (BGMSs) can lead to adverse health effects. The Diabetes Technology Society (DTS) Surveillance Program for cleared BGMSs is intended to protect people with diabetes from inaccurate, unreliable BGMS products that are currently on the market in the United States. The Surveillance Program will provide an independent assessment of the analytical performance of cleared BGMSs. The DTS BGMS Surveillance Program Steering Committee included experts in glucose monitoring, surveillance testing, and regulatory science. Over one year, the committee engaged in meetings and teleconferences aiming to describe how to conduct BGMS surveillance studies in a scientifically sound manner that is in compliance with good clinical practice and all relevant regulations. A clinical surveillance protocol was created that contains performance targets and analytical accuracy-testing studies with marketed BGMS products conducted by qualified clinical and laboratory sites. This protocol entitled "Protocol for the Diabetes Technology Society Blood Glucose Monitor System Surveillance Program" is attached as supplementary material. This program is needed because currently once a BGMS product has been cleared for use by the FDA, no systematic postmarket Surveillance Program exists that can monitor analytical performance and detect potential problems. This protocol will allow identification of inaccurate and unreliable BGMSs currently available on the US market. The DTS Surveillance Program will provide BGMS manufacturers a benchmark to understand the postmarket analytical performance of their products. Furthermore, patients, health care professionals, payers, and regulatory agencies will be able to use the results of the study to make informed decisions to, respectively, select, prescribe, finance, and regulate BGMSs on the market. © 2015 Diabetes Technology Society.

  10. Development of the Diabetes Technology Society Blood Glucose Monitor System Surveillance Protocol

    Science.gov (United States)

    Klonoff, David C.; Lias, Courtney; Beck, Stayce; Parkes, Joan Lee; Kovatchev, Boris; Vigersky, Robert A.; Arreaza-Rubin, Guillermo; Burk, Robert D.; Kowalski, Aaron; Little, Randie; Nichols, James; Petersen, Matt; Rawlings, Kelly; Sacks, David B.; Sampson, Eric; Scott, Steve; Seley, Jane Jeffrie; Slingerland, Robbert; Vesper, Hubert W.

    2015-01-01

    Background: Inaccurate blood glucsoe monitoring systems (BGMSs) can lead to adverse health effects. The Diabetes Technology Society (DTS) Surveillance Program for cleared BGMSs is intended to protect people with diabetes from inaccurate, unreliable BGMS products that are currently on the market in the United States. The Surveillance Program will provide an independent assessment of the analytical performance of cleared BGMSs. Methods: The DTS BGMS Surveillance Program Steering Committee included experts in glucose monitoring, surveillance testing, and regulatory science. Over one year, the committee engaged in meetings and teleconferences aiming to describe how to conduct BGMS surveillance studies in a scientifically sound manner that is in compliance with good clinical practice and all relevant regulations. Results: A clinical surveillance protocol was created that contains performance targets and analytical accuracy-testing studies with marketed BGMS products conducted by qualified clinical and laboratory sites. This protocol entitled “Protocol for the Diabetes Technology Society Blood Glucose Monitor System Surveillance Program” is attached as supplementary material. Conclusion: This program is needed because currently once a BGMS product has been cleared for use by the FDA, no systematic postmarket Surveillance Program exists that can monitor analytical performance and detect potential problems. This protocol will allow identification of inaccurate and unreliable BGMSs currently available on the US market. The DTS Surveillance Program will provide BGMS manufacturers a benchmark to understand the postmarket analytical performance of their products. Furthermore, patients, health care professionals, payers, and regulatory agencies will be able to use the results of the study to make informed decisions to, respectively, select, prescribe, finance, and regulate BGMSs on the market. PMID:26481642

  11. Technical specifications, Beaver Valley Power Station, Unit 2 (Docket No. 50-412): Appendix ''A'' to License No. NPF-73

    International Nuclear Information System (INIS)

    1987-08-01

    This report presents information concerning the Beaver Valley Power Station Unit 2 Reactor. Topics under discussion include: safety limits and limiting safety system settings; limiting condition for operation and surveillance requirements; design features; and administrative controls

  12. Surveillance Analysis Computer System (SACS) software requirements specification (SRS)

    International Nuclear Information System (INIS)

    Glasscock, J.A.; Flanagan, M.J.

    1995-09-01

    This document is the primary document establishing requirements for the Surveillance Analysis Computer System (SACS) Database, an Impact Level 3Q system. The purpose is to provide the customer and the performing organization with the requirements for the SACS Project

  13. Context-based object-of-interest detection for a generic traffic surveillance analysis system

    NARCIS (Netherlands)

    Bao, X.; Javanbakhti, S.; Zinger, S.; Wijnhoven, R.G.J.; With, de P.H.N.

    2014-01-01

    We present a new traffic surveillance video analysis system, focusing on building a framework with robust and generic techniques, based on both scene understanding and moving object-of-interest detection. Since traffic surveillance is widely applied, we want to design a single system that can be

  14. MATSurv: multisensor air traffic surveillance system

    Science.gov (United States)

    Yeddanapudi, Murali; Bar-Shalom, Yaakov; Pattipati, Krishna R.; Gassner, Richard R.

    1995-09-01

    This paper deals with the design and implementation of MATSurv 1--an experimental Multisensor Air Traffic Surveillance system. The proposed system consists of a Kalman filter based state estimator used in conjunction with a 2D sliding window assignment algorithm. Real data from two FAA radars is used to evaluate the performance of this algorithm. The results indicate that the proposed algorithm provides a superior classification of the measurements into tracks (i.e., the most likely aircraft trajectories) when compared to the aircraft trajectories obtained using the measurement IDs (squawk or IFF code).

  15. Twitter web-service for soft agent reporting in persistent surveillance systems

    Science.gov (United States)

    Rababaah, Haroun; Shirkhodaie, Amir

    2010-04-01

    Persistent surveillance is an intricate process requiring monitoring, gathering, processing, tracking, and characterization of many spatiotemporal events occurring concurrently. Data associated with events can be readily attained by networking of hard (physical) sensors. Sensors may have homogeneous or heterogeneous (hybrid) sensing modalities with different communication bandwidth requirements. Complimentary to hard sensors are human observers or "soft sensors" that can report occurrences of evolving events via different communication devices (e.g., texting, cell phones, emails, instant messaging, etc.) to the command control center. However, networking of human observers in ad-hoc way is rather a difficult task. In this paper, we present a Twitter web-service for soft agent reporting in persistent surveillance systems (called Web-STARS). The objective of this web-service is to aggregate multi-source human observations in hybrid sensor networks rapidly. With availability of Twitter social network, such a human networking concept can not only be realized for large scale persistent surveillance systems (PSS), but also, it can be employed with proper interfaces to expedite rapid events reporting by human observers. The proposed technique is particularly suitable for large-scale persistent surveillance systems with distributed soft and hard sensor networks. The efficiency and effectiveness of the proposed technique is measured experimentally by conducting several simulated persistent surveillance scenarios. It is demonstrated that by fusion of information from hard and soft agents improves understanding of common operating picture and enhances situational awareness.

  16. A methodological framework for the evaluation of syndromic surveillance systems: a case study of England.

    Science.gov (United States)

    Colón-González, Felipe J; Lake, Iain R; Morbey, Roger A; Elliot, Alex J; Pebody, Richard; Smith, Gillian E

    2018-04-24

    Syndromic surveillance complements traditional public health surveillance by collecting and analysing health indicators in near real time. The rationale of syndromic surveillance is that it may detect health threats faster than traditional surveillance systems permitting more timely, and hence potentially more effective public health action. The effectiveness of syndromic surveillance largely relies on the methods used to detect aberrations. Very few studies have evaluated the performance of syndromic surveillance systems and consequently little is known about the types of events that such systems can and cannot detect. We introduce a framework for the evaluation of syndromic surveillance systems that can be used in any setting based upon the use of simulated scenarios. For a range of scenarios this allows the time and probability of detection to be determined and uncertainty is fully incorporated. In addition, we demonstrate how such a framework can model the benefits of increases in the number of centres reporting syndromic data and also determine the minimum size of outbreaks that can or cannot be detected. Here, we demonstrate its utility using simulations of national influenza outbreaks and localised outbreaks of cryptosporidiosis. Influenza outbreaks are consistently detected with larger outbreaks being detected in a more timely manner. Small cryptosporidiosis outbreaks (framework constitutes a useful tool for public health emergency preparedness in multiple settings. The proposed framework allows the exhaustive evaluation of any syndromic surveillance system and constitutes a useful tool for emergency preparedness and response.

  17. A Radiation-Triggered Surveillance System for UF6 Cylinder Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Curtis, Michael M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Myjak, Mitchell J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-23

    This report provides background information and representative scenarios for testing a prototype radiation-triggered surveillance system at an operating facility that handles uranium hexafluoride (UF6) cylinders. The safeguards objective is to trigger cameras using radiation, or radiation and motion, rather than motion alone, to reduce significantly the number of image files generated by a motion-triggered system. The authors recommend the use of radiation-triggered surveillance at all facilities where cylinder paths are heavily traversed by personnel. The International Atomic Energy Agency (IAEA) has begun using surveillance cameras in the feed and withdrawal areas of gas centrifuge enrichment plants (GCEPs). The cameras generate imagery using elapsed time or motion, but this creates problems in areas occupied 24/7 by personnel. Either motion-or-interval-based triggering generates thousands of review files over the course of a month. Since inspectors must review the files to verify operator material-flow-declarations, a plethora of files significantly extends the review process. The primary advantage of radiation-triggered surveillance is the opportunity to obtain full-time cylinder throughput verification versus what presently amounts to part-time verification. Cost savings should be substantial, as the IAEA presently uses frequent unannounced inspections to verify cylinder-throughput declarations. The use of radiation-triggered surveillance allows the IAEA to implement less frequent unannounced inspections for the purpose of flow verification, but its principal advantage is significantly shorter and more effective inspector video reviews.

  18. Automated intelligent video surveillance system for ships

    Science.gov (United States)

    Wei, Hai; Nguyen, Hieu; Ramu, Prakash; Raju, Chaitanya; Liu, Xiaoqing; Yadegar, Jacob

    2009-05-01

    To protect naval and commercial ships from attack by terrorists and pirates, it is important to have automatic surveillance systems able to detect, identify, track and alert the crew on small watercrafts that might pursue malicious intentions, while ruling out non-threat entities. Radar systems have limitations on the minimum detectable range and lack high-level classification power. In this paper, we present an innovative Automated Intelligent Video Surveillance System for Ships (AIVS3) as a vision-based solution for ship security. Capitalizing on advanced computer vision algorithms and practical machine learning methodologies, the developed AIVS3 is not only capable of efficiently and robustly detecting, classifying, and tracking various maritime targets, but also able to fuse heterogeneous target information to interpret scene activities, associate targets with levels of threat, and issue the corresponding alerts/recommendations to the man-in- the-loop (MITL). AIVS3 has been tested in various maritime scenarios and shown accurate and effective threat detection performance. By reducing the reliance on human eyes to monitor cluttered scenes, AIVS3 will save the manpower while increasing the accuracy in detection and identification of asymmetric attacks for ship protection.

  19. Framework for evaluating public health surveillance systems for early detection of outbreaks: recommendations from the CDC Working Group.

    Science.gov (United States)

    Buehler, James W; Hopkins, Richard S; Overhage, J Marc; Sosin, Daniel M; Tong, Van

    2004-05-07

    The threat of terrorism and high-profile disease outbreaks has drawn attention to public health surveillance systems for early detection of outbreaks. State and local health departments are enhancing existing surveillance systems and developing new systems to better detect outbreaks through public health surveillance. However, information is limited about the usefulness of surveillance systems for outbreak detection or the best ways to support this function. This report supplements previous guidelines for evaluating public health surveillance systems. Use of this framework is intended to improve decision-making regarding the implementation of surveillance for outbreak detection. Use of a standardized evaluation methodology, including description of system design and operation, also will enhance the exchange of information regarding methods to improve early detection of outbreaks. The framework directs particular attention to the measurement of timeliness and validity for outbreak detection. The evaluation framework is designed to support assessment and description of all surveillance approaches to early detection, whether through traditional disease reporting, specialized analytic routines for aberration detection, or surveillance using early indicators of disease outbreaks, such as syndromic surveillance.

  20. R and D study on on-line criticality surveillance system (IV)

    International Nuclear Information System (INIS)

    Yamada, Sumasu

    2000-02-01

    Developing an inexpensive on-line criticality surveillance system is required for ensuring the safety of nuclear fuel reprocessing plants. Based on the series of researches for five years, R and D study on On-line Criticality Surveillance system has been carried out since 1996. The concept of this Criticality Surveillance System is based on the Auto-Regressive Moving Average (ARMA) model identification algorithms to the time series of signal fluctuation of a neutron detector. We have proposed several new ideas of modification to the original design of the Criticality Surveillance System, and also reported some results of numerical analysis over the DCA experiments. In those days, DOS/V personal computers with Microsoft Windows have came into wide use instead of those based on the MS-DOS, which have been popular in Japan. NEC, a major maker of MS-DOS computers, stopped the production of MS-DOS computers and changed their management policy toward production of DOS/V personal computers. Our researches have been developed using MS-DOS computers. For the effective use of these important results, it became an urgent theme to transplant all programs developed on MS-DOS computers into computers with the OS, which is not easily affected by commercialism. Since the design concept should be based on high reliability, electromagnetic disturbance-free and high expandability, and also computers have achieved remarkably high performance as well as low price in these days, these computers should be used not only as a simple signal processing unit but also a totally integrated signal analyzing system along with conventional signal analyzing software in stead of IC chips with analyzing soft wares. This configuration enables us to easily introduce newly developed techniques and to provide supplement information. Then, this approach can enhance the reliability of the Criticality Surveillance System without addition of any special devices, and also provide the flexibility of the system

  1. Quantitative and qualitative assessment of the bovine abortion surveillance system in France.

    Science.gov (United States)

    Bronner, Anne; Gay, Emilie; Fortané, Nicolas; Palussière, Mathilde; Hendrikx, Pascal; Hénaux, Viviane; Calavas, Didier

    2015-06-01

    Bovine abortion is the main clinical sign of bovine brucellosis, a disease of which France has been declared officially free since 2005. To ensure the early detection of any brucellosis outbreak, event-driven surveillance relies on the mandatory notification of bovine abortions and the brucellosis testing of aborting cows. However, the under-reporting of abortions appears frequent. Our objectives were to assess the aptitude of the bovine abortion surveillance system to detect each and every bovine abortion and to identify factors influencing the system's effectiveness. We evaluated five attributes defined by the U.S. Centers for Disease Control with a method suited to each attribute: (1) data quality was studied quantitatively and qualitatively, as this factor considerably influences data analysis and results; (2) sensitivity and representativeness were estimated using a unilist capture-recapture approach to quantify the surveillance system's effectiveness; (3) acceptability and simplicity were studied through qualitative interviews of actors in the field, given that the surveillance system relies heavily on abortion notifications by farmers and veterinarians. Our analysis showed that (1) data quality was generally satisfactory even though some errors might be due to actors' lack of awareness of the need to collect accurate data; (2) from 2006 to 2011, the mean annual sensitivity - i.e. the proportion of farmers who reported at least one abortion out of all those who detected such events - was around 34%, but was significantly higher in dairy than beef cattle herds (highlighting a lack of representativeness); (3) overall, the system's low sensitivity was related to its low acceptability and lack of simplicity. This study showed that, in contrast to policy-makers, most farmers and veterinarians perceived the risk of a brucellosis outbreak as negligible. They did not consider sporadic abortions as a suspected case of brucellosis and usually reported abortions only to

  2. Strengthening Injury Surveillance System in Iran

    Institute of Scientific and Technical Information of China (English)

    Seyed Abbas Motevalian; Mashyaneh Haddadi; Hesam Akbari; Reza Khorramirouz; Soheil Saadat; Arash Tehrani; Vafa Rahimi-Movaghar

    2011-01-01

    Objective:To strengthen the current Injury Surveillance System (IS System) in order to better monitor injury conditions,improve protection ways and promote safety.Methods:At first we carried out a study to evaluate the frameworks of IS System in the developed countries.Then all the available documents from World Health OrganizationEastern Mediterranean Regional Organization,as well as Minister of Health and Medical Education concerning Iran were reviewed.Later a national stakeholder's consultation was held to collect opinions and views.A national workshop was also intended for provincial representatives from 41 universities to identify the barriers and limitations of the existing program and further to strengthen injury surveillance.Results:The evaluation of the current IS System revealed many problems,mainly presented as lack of accurate pre- and post-hospital death registry,need of precise injury data registry in outpatient medical centers,incomplete injury data registry in hospitals and lack of accuracy in definition of variables in injury registry.The five main characteristics of current IS System including flexibility,acceptability,simplicity,usefulness and timeliness were evaluated as moderate by experts.Contusions:Major revisions must be considered in the current IS System in Iran.The following elements should be added to the questionnaire:identifier,manner of arrival to the hospital,situation of the injured patient,consumption of alcohol and opioids,other involved participants in the accident,intention,severity and site of injury,side effects of surgery and medication,as well as one month follow-up results.Data should be collected from 10% of all hospitals in Iran and analyzed every 3 months.Simultaneously data should be online to be retrieved by researches.

  3. A Novel Surveillance System Applied in Civil Airport

    Directory of Open Access Journals (Sweden)

    Sun Hua Bo

    2016-01-01

    Full Text Available Conventional security monitoring of civil airport usually uses a fixed camera to acquire images. There are several problems with performance including difficulties introduced in the information transmission, storage, and analysis of the process. Insect compound eyes offer unique advantages for moving target capture and these have attracted the attention of many researchers in recent years. This paper contributes to this research by proposing a new surveillance system applied in civil airport. We discuss the finished bionic structure of the system, the development of the bionic control circuit, and introduce the proposed mathematical model of bionic compound eyes for data acquisition and image mosaic. Image matching for large view is also illustrated with different conditions. This mode and algorithm effectively achieve safety surveillance of airport with large field of view and high real-time processing.

  4. Community-Operated Environmental Surveillance Program

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the environmental surveillance activities with which citizens living near the Hanford Site have been participating. Local teachers have been managing and operating three special radiological air sampling stations located in Richland, Basin City, and Franklin County, Washington. Other expansion efforts of this program are also described.

  5. Community-Operated Environmental Surveillance Program

    International Nuclear Information System (INIS)

    Anon.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the environmental surveillance activities with which citizens living near the Hanford Site have been participating. Local teachers have been managing and operating three special radiological air sampling stations located in Richland, Basin City, and Franklin County, Washington. Other expansion efforts of this program are also described

  6. A conveyor system for feeding work stations

    International Nuclear Information System (INIS)

    Sheader, J.; Davies, K.J.

    1986-01-01

    A conveyor system comprises carriages drive, e.g. by a linear motor, a pre-arranged sequence of steps to move workpieces in forward and reverse directions between work stations. Each work station has a part position and a work position and each carriage has a number of compartments for workpieces spaced apart at a pitch equal to the spacing between the part and work positions at each station. Transfer means at the work stations move workpieces between the carriage compartments and the part and work positions. The workpieces can be nuclear fuel pins mounted in carriers and the carriages shuttle to and fro between adjacent stations to move fuel pins and carriers in a forward direction and the return empty carriers in a reverse direction. (author)

  7. Compositional Verification of Multi-Station Interlocking Systems

    DEFF Research Database (Denmark)

    Macedo, Hugo Daniel dos Santos; Fantechi, Alessandro; Haxthausen, Anne Elisabeth

    2016-01-01

    pose a big challenge to current verification methodologies, due to the explosion of state space size as soon as large, if not medium sized, multi-station systems have to be controlled. For these reasons, verification techniques that exploit locality principles related to the topological layout...... of the controlled system to split in different ways the state space have been investigated. In particular, compositional approaches divide the controlled track network in regions that can be verified separately, once proper assumptions are considered on the way the pieces are glued together. Basing on a successful...... method to verify the size of rather large networks, we propose a compositional approach that is particularly suitable to address multi-station interlocking systems which control a whole line composed of stations linked by mainline tracks. Indeed, it turns out that for such networks, and for the adopted...

  8. Distributed systems for protecting nuclear power stations

    International Nuclear Information System (INIS)

    Jover, P.

    1980-05-01

    The advantages of distributed control systems for the control of nuclear power stations are obviously of great interest. Some years ago, EPRI, (Electric Power Research Institute) showed that multiplexing the signals is technically feasible, that it enables the availability specifications to be met and costs to be reduced. Since then, many distributed control systems have been proposed by the manufacturers. This note offers some comments on the application of the distribution concept to protection systems -what should be distributed- and ends with a brief description of a protection system based on microprocessors for the pressurized power stations now being built in France [fr

  9. Functional requirements for core surveillance systems

    International Nuclear Information System (INIS)

    Andersson, T.

    2000-01-01

    Operating experience at Ringhals-2 has demonstrated the feasibility of a mixed core surveillance system comprised of fixed in-core detectors combined with the original movable detector system. A small number of fixed in-core detectors provide continuous measurement of the thermal margins while the movable detectors are used mainly at start-up to verify the expected power distribution. Reactor noise diagnostics and neural networks can further improve the monitoring system. The reliability of the movable detector system can be improved by mechanical simplification. Wear and maintenance costs are lowered if the required flux-mapping frequency is reduced. Improved computer codes make the measurement uncertainties less dependent on the number of instrumented positions. A mixed system requires new types of technical specifications. (author)

  10. Work-Related Lung Disease Surveillance System (eWoRLD)

    Data.gov (United States)

    U.S. Department of Health & Human Services — A surveillance system that provides morbidity, mortality, and workplace exposure data on work-related respiratory diseases by geographic region, industry and...

  11. A survey of core and support activities of communicable disease surveillance systems at operating-level CDCs in China.

    Science.gov (United States)

    Xiong, Weiyi; Lv, Jun; Li, Liming

    2010-11-17

    In recent years, problems like insufficient coordination, low efficiency, and heavy working load in national communicable disease surveillance systems in China have been pointed out by many researchers. To strengthen the national communicable disease surveillance systems becomes an immediate concern. Since the World Health Organization has recommended that a structured approach to strengthen national communicable disease surveillance must include an evaluation to existing systems which usually begins with a systematic description, we conducted the first survey for communicable disease surveillance systems in China, in order to understand the situation of core and support surveillance activities at province-level and county-level centers for disease control and prevention (CDCs). A nationwide survey was conducted by mail between May and October 2006 to investigate the implementation of core and support activities of the Notifiable Disease Reporting System (NDRS) and disease-specific surveillance systems in all of the 31 province-level and selected 14 county-level CDCs in Mainland China The comments on the performance of communicable disease surveillance systems were also collected from the directors of CDCs in this survey. The core activities of NDRS such as confirmation, reporting and analysis and some support activities such as supervision and staff training were found sufficient in both province-level and county-level surveyed CDCs, but other support activities including information feedback, equipment and financial support need to be strengthened in most of the investigated CDCs. A total of 47 communicable diseases or syndromes were under surveillance at province level, and 20 diseases or syndromes at county level. The activities among different disease-specific surveillance systems varied widely. Acute flaccid paralysis (AFP), measles and tuberculosis (TB) surveillance systems got relatively high recognition both at province level and county level. China has

  12. Suboptimal processor for anomaly detection for system surveillance and diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Ciftcioglu, Oe.; Hoogenboom, J.E.; Dam, H. van

    1989-06-01

    Anomaly detection for nuclear reactor surveillance and diagnosis is described. The residual noise obtained as a result of autoregressive (AR) modelling is essential to obtain high sensitivity for anomaly detection. By means of the method of hypothesis testing a suboptimal anomaly detection processor is devised for system surveillance and diagnosis. Experiments are carried out to investigate the performance of the processor, which is in particular of interest for on-line and real-time applications.

  13. On-line surveillance system for Borssele nuclear power plant monitoring and diagnostics

    International Nuclear Information System (INIS)

    Tuerkcan, E.; Ciftcioglu, Oe.

    1993-08-01

    An operating on-line surveillance and diagnostic system is described where information processing for monitoring and fault diagnosis and plant maintenance are addressed. The surveillance system by means of its realtime multiprocessing, multitasking execution capabilities can perform plant-wide and wide-range monitoring for enhanced plant safety and operational reliability as well as enhanced maintenance. At the same time the system provides the possibilities for goal-oriented research and development such as estimation, filtering, verification and validation and neural networks. (orig./HP)

  14. Technical specifications, Millstone Nuclear Power Station, Unit No. 3 (Docket No. 50-423). Appendix ''A'' to License No. NPF-49

    International Nuclear Information System (INIS)

    1986-01-01

    Information is presented concerning specifications on the following aspects of the Millstone Nuclear Power Station, Unit No. 3: safety limits and limiting safety system settings; limiting conditions for operation and surveillance requirements; design features; and administrative controls

  15. Surveillance for travel-related disease--GeoSentinel Surveillance System, United States, 1997-2011.

    Science.gov (United States)

    Harvey, Kira; Esposito, Douglas H; Han, Pauline; Kozarsky, Phyllis; Freedman, David O; Plier, D Adam; Sotir, Mark J

    2013-07-19

    In 2012, the number of international tourist arrivals worldwide was projected to reach a new high of 1 billion arrivals, a 48% increase from 674 million arrivals in 2000. International travel also is increasing among U.S. residents. In 2009, U.S. residents made approximately 61 million trips outside the country, a 5% increase from 1999. Travel-related morbidity can occur during or after travel. Worldwide, 8% of travelers from industrialized to developing countries report becoming ill enough to seek health care during or after travel. Travelers have contributed to the global spread of infectious diseases, including novel and emerging pathogens. Therefore, surveillance of travel-related morbidity is an essential component of global public health surveillance and will be of greater importance as international travel increases worldwide. September 1997-December 2011. GeoSentinel is a clinic-based global surveillance system that tracks infectious diseases and other adverse health outcomes in returned travelers, foreign visitors, and immigrants. GeoSentinel comprises 54 travel/tropical medicine clinics worldwide that electronically submit demographic, travel, and clinical diagnosis data for all patients evaluated for an illness or other health condition that is presumed to be related to international travel. Clinical information is collected by physicians with expertise or experience in travel/tropical medicine. Data collected at all sites are entered electronically into a database, which is housed at and maintained by CDC. The GeoSentinel network membership program comprises 235 additional clinics in 40 countries on six continents. Although these network members do not report surveillance data systematically, they can report unusual or concerning diagnoses in travelers and might be asked to perform enhanced surveillance in response to specific health events or concerns. During September 1997-December 2011, data were collected on 141,789 patients with confirmed or

  16. DASH - Youth Risk Behavior Surveillance System (YRBSS): Middle School

    Data.gov (United States)

    U.S. Department of Health & Human Services — 1991-2015. Middle School Dataset. The Youth Risk Behavior Surveillance System (YRBSS) monitors six categories of priority health behaviors among youth and young...

  17. DASH - Youth Risk Behavior Surveillance System (YRBSS): High School

    Data.gov (United States)

    U.S. Department of Health & Human Services — 1991-2015. High School Dataset. The Youth Risk Behavior Surveillance System (YRBSS) monitors six categories of priority health behaviors among youth and young...

  18. Cooperating expert systems for space station power distribution management

    International Nuclear Information System (INIS)

    Nguyen, T.A.; Chiou, W.C.

    1986-01-01

    In a complex system such as the manned Space Station, it is deemed necessary that many expert systems must perform tasks in a concurrent and cooperative manner. An important question to arise is: what cooperative-task-performing models are appropriate for multiple expert systems to jointly perform tasks. The solution to this question will provide a crucial automation design criteria for the Space Station complex systems architecture. Based on a client/server model for performing tasks, the authors have developed a system that acts as a front-end to support loosely-coupled communications between expert systems running on multiple Symbolics machines. As an example, they use the two ART*-based expert systems to demonstrate the concept of parallel symbolic manipulation for power distribution management and dynamic load planner/scheduler in the simulated Space Station environment. This on-going work will also explore other cooperative-task-performing models as alternatives which can evaluate inter and intra expert system communication mechanisms. It will serve as a testbed and a bench-marking tool for other Space Station expert subsystem communication and information exchange

  19. Cooperating Expert Systems For Space Station Power Distribution Management

    Science.gov (United States)

    Nguyen, T. A.; Chiou, W. C.

    1987-02-01

    In a complex system such as the manned Space Station, it is deem necessary that many expert systems must perform tasks in a concurrent and cooperative manner. An important question arise is: what cooperative-task-performing models are appropriate for multiple expert systems to jointly perform tasks. The solution to this question will provide a crucial automation design criteria for the Space Station complex systems architecture. Based on a client/server model for performing tasks, we have developed a system that acts as a front-end to support loosely-coupled communications between expert systems running on multiple Symbolics machines. As an example, we use two ART*-based expert systems to demonstrate the concept of parallel symbolic manipulation for power distribution management and dynamic load planner/scheduler in the simulated Space Station environment. This on-going work will also explore other cooperative-task-performing models as alternatives which can evaluate inter and intra expert system communication mechanisms. It will be served as a testbed and a bench-marking tool for other Space Station expert subsystem communication and information exchange.

  20. Death analysis of residents in an area of twenty kilometers around Qinshan nuclear power station

    International Nuclear Information System (INIS)

    Ma Mingqiang; Lu Zhunrong; Zheng Wen; Sun Peizhi

    2001-01-01

    Objective: To set up a data bank for residents health condition 20 kilometers within around Qinshan nuclear power station. Methods: Combining with retrospective investigation, the relevant data were acquired from medical certification for resident's death reported by all local disease surveillance. Results: The mortality rate of these residents from 1988 to 1999 was 6.92%. The first course of mortality was diseases of respiratory system, the second of circulatory system, and the third was malignant tumor. The first 5 death causes among all male and female persons were diseases of respiratory system and circulatory system, malignant tumor, injuries and poisoning, diseases of digestive system. The mortality rate for malignant tumor was 121.33/100000 (the standard death rate is : 100.13/100000), and liver cancer was the first death cause, while lung and stomach cancers, the second and the third, respectively. The main death causes in juvenile and youth was leukemia, but liver cancer and lung cancer were the main courses of death in the middle-aged, and in old people, lung and liver cancers. Conclusion: The chronic non-infectious diseases in respiratory system, circulatory system etc, are the major death causes in the residents, the mortality rate for malignant tumor in them is lower than that reported by provincial disease surveillance station

  1. Development of Compact Surveillance and Monitoring System 'COSMOS'

    International Nuclear Information System (INIS)

    Ogawa, Hironobu; Mukaiyama, Takehiko

    1999-03-01

    The Compact Surveillance and Monitoring System (COSMOS) was developed by the Japan Atomic Energy Research Institute (JAERI) for the International Atomic Energy Agency (IAEA) as a safeguards surveillance system under the JASPAS (Japan Support Programme for Agency Safeguards) with the collaboration of the Sony Corporation. It was intended as a direct replacement to the Twin Minolta film camera system. The COSMOS system can operate with a self-contained battery, record 30,000 scenes with an 8 mm video cassette tape and operate continuously for three months without human intervention. It can also operate by AC power supply for more than three months, and record 45,000 scenes in an 8 mm video cassette tape. The COSMOS system consists of two units, one is the Recording Unit and the other is the Setup/Review Unit. The Recording Unit consists of a main frame, four modules and a tamperproof housing. The four modules are a small CCD (Charge Coupled Device) camera with an auto-iris lens and a specific VTR (Video Tape Recorder), a video frame memory module, a system control module, and a DC or an AC power module. Currently, the COSMOS is the only safeguards video surveillance system without the need of external power supply for three months. In 1992 thirteen COSMOS units were successfully tested for the reliability by both the IAEA and the JAERI. None of mechanical failure was observed. On the one hand, the battery operation tests using four units were successfully carried out with 5 minutes time interval for three months. Three units were also tested in the field and no failure was observed. The COSMOS was accepted as the routine-use device for international safeguards by the IAEA in August 1993. The total of 90 units were purchased by the IAEA from the manufacturer, SONY, and also several units were purchased by the Science and Technology Agency (STA) of Japan for the STA/IAEA joint-use in Japan. (author)

  2. Development of Compact Surveillance and Monitoring System `COSMOS`

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Hironobu; Mukaiyama, Takehiko [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1999-03-01

    The Compact Surveillance and Monitoring System (COSMOS) was developed by the Japan Atomic Energy Research Institute (JAERI) for the International Atomic Energy Agency (IAEA) as a safeguards surveillance system under the JASPAS (Japan Support Programme for Agency Safeguards) with the collaboration of the Sony Corporation. It was intended as a direct replacement to the Twin Minolta film camera system. The COSMOS system can operate with a self-contained battery, record 30,000 scenes with an 8 mm video cassette tape and operate continuously for three months without human intervention. It can also operate by AC power supply for more than three months, and record 45,000 scenes in an 8 mm video cassette tape. The COSMOS system consists of two units, one is the Recording Unit and the other is the Setup/Review Unit. The Recording Unit consists of a main frame, four modules and a tamperproof housing. The four modules are a small CCD (Charge Coupled Device) camera with an auto-iris lens and a specific VTR (Video Tape Recorder), a video frame memory module, a system control module, and a DC or an AC power module. Currently, the COSMOS is the only safeguards video surveillance system without the need of external power supply for three months. In 1992 thirteen COSMOS units were successfully tested for the reliability by both the IAEA and the JAERI. None of mechanical failure was observed. On the one hand, the battery operation tests using four units were successfully carried out with 5 minutes time interval for three months. Three units were also tested in the field and no failure was observed. The COSMOS was accepted as the routine-use device for international safeguards by the IAEA in August 1993. The total of 90 units were purchased by the IAEA from the manufacturer, SONY, and also several units were purchased by the Science and Technology Agency (STA) of Japan for the STA/IAEA joint-use in Japan. (author)

  3. Operator Station Design System - A computer aided design approach to work station layout

    Science.gov (United States)

    Lewis, J. L.

    1979-01-01

    The Operator Station Design System is resident in NASA's Johnson Space Center Spacecraft Design Division Performance Laboratory. It includes stand-alone minicomputer hardware and Panel Layout Automated Interactive Design and Crew Station Assessment of Reach software. The data base consists of the Shuttle Transportation System Orbiter Crew Compartment (in part), the Orbiter payload bay and remote manipulator (in part), and various anthropometric populations. The system is utilized to provide panel layouts, assess reach and vision, determine interference and fit problems early in the design phase, study design applications as a function of anthropometric and mission requirements, and to accomplish conceptual design to support advanced study efforts.

  4. Design and Implementation of an Embedded Smart Intruder Surveillance System

    Directory of Open Access Journals (Sweden)

    Sabri Naseer

    2018-01-01

    Full Text Available Remote and scattered valuable and sensitive locations such as labs and offices inside university campus need efficient monitoring and warning system. As well as scattered area and belonging. This research presents a Real-Time intruder Surveillance System based on a single board computer (SBC. Thus the design and development of a cost effective surveillance management system based SBC that can be deployed efficiently in remote and scattered locations such as universities belonging. The fusion of embedded Python codes with SBC that attached to cameras, Long distance sensors, alerting circuitry and wireless module presents a novel integration based effective cost solution and enhances SBC of much flexibility of improvement and development for pervasive remote locations. The system proves the high integrity of smooth working with web application, it’s cost effective and thus can be deployed as many of units to seize and concisely covered remote and scattered area as well as university belonging and departments. The system can be administrated by a remote user sparsely or geographically away from any networked workstation. The proposed solution offers efficient stand alone, flexibility to upgrade and cheap development and installation as well as cost effective ubiquitous surveillance solution. In conclusion, the system acceptable boundaries of successful intruder recognition and warning alert are computed between 1m and 3m distance of intruder from system camera. Recognition rate of 95% and 83% are achieved and the successful warning alert were in the range of 86-97%.

  5. Sapphire: Canada's Answer to Space-Based Surveillance of Orbital Objects

    Science.gov (United States)

    Maskell, P.; Oram, L.

    The Canadian Department of National Defence is in the process of developing the Canadian Space Surveillance System (CSSS) as the main focus of the Surveillance of Space (SofS) Project. The CSSS consists of two major elements: the Sapphire System and the Sensor System Operations Centre (SSOC). The space segment of the Sapphire System is comprised of the Sapphire Satellite - an autonomous spacecraft with an electro-optical payload which will act as a contributing sensor to the United States (US) Space Surveillance Network (SSN). It will operate in a circular, sunsynchronous orbit at an altitude of approximately 750 kilometers and image a minimum of 360 space objects daily in orbits ranging from 6,000 to 40,000 kilometers in altitude. The ground segment of the Sapphire System is composed of a Spacecraft Control Center (SCC), a Satellite Processing and Scheduling Facility (SPSF), and the Sapphire Simulator. The SPSF will be responsible for data transmission, reception, and processing while the SCC will serve to control and monitor the Sapphire Satellite. Surveillance data will be received from Sapphire through two ground stations. Following processing by the SPSF, the surveillance data will then be forwarded to the SSOC. The SSOC will function as the interface between the Sapphire System and the US Joint Space Operations Center (JSpOC). The JSpOC coordinates input from various sensors around the world, all of which are a part of the SSN. The SSOC will task the Sapphire System daily and provide surveillance data to the JSpOC for correlation with data from other SSN sensors. This will include orbital parameters required to predict future positions of objects to be tracked. The SSOC receives daily tasking instructions from the JSpOC to determine which objects the Sapphire spacecraft is required to observe. The advantage of this space-based sensor over ground-based telescopes is that weather and time of day are not factors affecting observation. Thus, space-based optical

  6. ACP Facility Safety Surveillance System Installation

    International Nuclear Information System (INIS)

    You, Gil Sung; Kook, D. H.; Choung, W. M.; Ku, J. H.; Cho, I. J.; You, G. S.; Kwon, K. C.; Lee, W. K.; Lee, E. P.

    2006-10-01

    The Advanced spent fuel Conditioning Process is under development for effective management of spent fuel by converting UO 2 into U-metal. For demonstration of this process, α-γ type new hotcell was built in the IMEF basement. All facilities which treat radioactive materials must manage CCTV system which is under control of Health Physics department. Three main points (including hotcell rear door area) have each camera, but operators who are in charge of facility management need to check the safety of the facility immediately through the network in his office. This needs introduce additional network cameras installation and this new surveillance system is expected to update the whole safety control ability with existing system

  7. Recording and surveillance systems for periodontal diseases

    DEFF Research Database (Denmark)

    Beltrán-Aguilar, Eugenio D; Eke, Paul I; Thornton-Evans, Gina

    2012-01-01

    This paper describes tools used to measure periodontal diseases and the integration of these tools into surveillance systems. Tools to measure periodontal diseases at the surveillance level have focussed on current manifestations of disease (e.g. gingival inflammation) or disease sequelae (e.......g. periodontal pocket depth or loss of attachment). All tools reviewed in this paper were developed based on the state of the science of the pathophysiology of periodontal disease at the time of their design and the need to provide valid and reliable measurements of the presence and severity of periodontal...... diseases. Therefore, some of these tools are no longer valid. Others, such as loss of periodontal attachment, are the current de-facto tools but demand many resources to undertake periodical assessment of the periodontal health of populations. Less complex tools such as the Community Periodontal Index...

  8. Smart sensing surveillance system

    Science.gov (United States)

    Hsu, Charles; Chu, Kai-Dee; O'Looney, James; Blake, Michael; Rutar, Colleen

    2010-04-01

    Unattended ground sensor (UGS) networks have been widely used in remote battlefield and other tactical applications over the last few decades due to the advances of the digital signal processing. The UGS network can be applied in a variety of areas including border surveillance, special force operations, perimeter and building protection, target acquisition, situational awareness, and force protection. In this paper, a highly-distributed, fault-tolerant, and energyefficient Smart Sensing Surveillance System (S4) is presented to efficiently provide 24/7 and all weather security operation in a situation management environment. The S4 is composed of a number of distributed nodes to collect, process, and disseminate heterogeneous sensor data. Nearly all S4 nodes have passive sensors to provide rapid omnidirectional detection. In addition, Pan- Tilt- Zoom- (PTZ) Electro-Optics EO/IR cameras are integrated to selected nodes to track the objects and capture associated imagery. These S4 camera-connected nodes will provide applicable advanced on-board digital image processing capabilities to detect and track the specific objects. The imaging detection operations include unattended object detection, human feature and behavior detection, and configurable alert triggers, etc. In the S4, all the nodes are connected with a robust, reconfigurable, LPI/LPD (Low Probability of Intercept/ Low Probability of Detect) wireless mesh network using Ultra-wide band (UWB) RF technology, which can provide an ad-hoc, secure mesh network and capability to relay network information, communicate and pass situational awareness and messages. The S4 utilizes a Service Oriented Architecture such that remote applications can interact with the S4 network and use the specific presentation methods. The S4 capabilities and technologies have great potential for both military and civilian applications, enabling highly effective security support tools for improving surveillance activities in densely crowded

  9. Open System of Agile Ground Stations, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — There is an opportunity to build the HETE-2/TESS network of ground stations into an innovative and powerful Open System of Agile Stations, by developing a low-cost...

  10. A generic flexible and robust approach for intelligent real-time video-surveillance systems

    Science.gov (United States)

    Desurmont, Xavier; Delaigle, Jean-Francois; Bastide, Arnaud; Macq, Benoit

    2004-05-01

    In this article we present a generic, flexible and robust approach for an intelligent real-time video-surveillance system. A previous version of the system was presented in [1]. The goal of these advanced tools is to provide help to operators by detecting events of interest in visual scenes and highlighting alarms and compute statistics. The proposed system is a multi-camera platform able to handle different standards of video inputs (composite, IP, IEEE1394 ) and which can basically compress (MPEG4), store and display them. This platform also integrates advanced video analysis tools, such as motion detection, segmentation, tracking and interpretation. The design of the architecture is optimised to playback, display, and process video flows in an efficient way for video-surveillance application. The implementation is distributed on a scalable computer cluster based on Linux and IP network. It relies on POSIX threads for multitasking scheduling. Data flows are transmitted between the different modules using multicast technology and under control of a TCP-based command network (e.g. for bandwidth occupation control). We report here some results and we show the potential use of such a flexible system in third generation video surveillance system. We illustrate the interest of the system in a real case study, which is the indoor surveillance.

  11. [Development of an index system for the comprehensive evaluation on public health emergency events surveillance system in China].

    Science.gov (United States)

    Hong, Zhiheng; Ni, Daxin; Cao, Yang; Meng, Ling; Tu, Wenxiao; Li, Leilei; Li, Qun; Jin, Lianmei

    2015-06-01

    To establish a comprehensive evaluation index system for the China Public Health Emergency Events Surveillance System (CPHEESS). A draft index system was built through literature review and under the consideration of the characteristics on CPHEESS. Delphi method was adapted to determine the final index system. The index system was divided into primary, secondary and tertiary levels. There were 4 primary indicators: System structure, Network platform, Surveillance implementation reports with Data analysis and utilization. There were 16 secondary and 70 tertiary indicators being set, with System structure including 14 tertiary indicators (accounted for 20.00%), 21 Network platforms (accounted for 30.00%). Twenty-four Surveillance implementation reports (accounted for 34.29%), 11 Data analysis and utilization (accounted for 15.71%). The average score of importance of each indicators was 4.29 (3.77-4.94), with an average coefficient variation as 0.14 (0.12-0.16). The mean Chronbach's α index was 0.84 (0.81-0.89). The adaptability of each related facilities indicator was specified. The primary indicators were set in accordance with the characteristics and goals of the surveillance systems. Secondary indicators provided key elements in the management and control of the system while the tertiary indicators were available and operative. The agreement rate of experts was high with good validity and reliability. This index system could be used for CPHEESS in future.

  12. Semi-automated CCTV surveillance: the effects of system confidence, system accuracy and task complexity on operator vigilance, reliance and workload.

    Science.gov (United States)

    Dadashi, N; Stedmon, A W; Pridmore, T P

    2013-09-01

    Recent advances in computer vision technology have lead to the development of various automatic surveillance systems, however their effectiveness is adversely affected by many factors and they are not completely reliable. This study investigated the potential of a semi-automated surveillance system to reduce CCTV operator workload in both detection and tracking activities. A further focus of interest was the degree of user reliance on the automated system. A simulated prototype was developed which mimicked an automated system that provided different levels of system confidence information. Dependent variable measures were taken for secondary task performance, reliance and subjective workload. When the automatic component of a semi-automatic CCTV surveillance system provided reliable system confidence information to operators, workload significantly decreased and spare mental capacity significantly increased. Providing feedback about system confidence and accuracy appears to be one important way of making the status of the automated component of the surveillance system more 'visible' to users and hence more effective to use. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  13. Solar dynamic power systems for space station

    Science.gov (United States)

    Irvine, Thomas B.; Nall, Marsha M.; Seidel, Robert C.

    1986-01-01

    The Parabolic Offset Linearly Actuated Reflector (POLAR) solar dynamic module was selected as the baseline design for a solar dynamic power system aboard the space station. The POLAR concept was chosen over other candidate designs after extensive trade studies. The primary advantages of the POLAR concept are the low mass moment of inertia of the module about the transverse boom and the compactness of the stowed module which enables packaging of two complete modules in the Shuttle orbiter payload bay. The fine pointing control system required for the solar dynamic module has been studied and initial results indicate that if disturbances from the station are allowed to back drive the rotary alpha joint, pointing errors caused by transient loads on the space station can be minimized. This would allow pointing controls to operate in bandwidths near system structural frequencies. The incorporation of the fine pointing control system into the solar dynamic module is fairly straightforward for the three strut concentrator support structure. However, results of structural analyses indicate that this three strut support is not optimum. Incorporation of a vernier pointing system into the proposed six strut support structure is being studied.

  14. Dosimetry systems in nuclear power stations

    International Nuclear Information System (INIS)

    Weidmann, U.

    1992-01-01

    In the following paper the necessity of the use of electronic dosimetry systems in nuclear power stations is presented, also encompassing the tasks which this type of systems has to fulfill. Based on examples the construction principles and the application possibilities of a PC supported system are described. 5 figs

  15. Developing Agent-Oriented Video Surveillance System through Agent-Oriented Methodology (AOM

    Directory of Open Access Journals (Sweden)

    Cheah Wai Shiang

    2016-12-01

    Full Text Available Agent-oriented methodology (AOM is a comprehensive and unified agent methodology for agent-oriented software development. Although AOM is claimed to be able to cope with a complex system development, it is still not yet determined up to what extent this may be true. Therefore, it is vital to conduct an investigation to validate this methodology. This paper presents the adoption of AOM in developing an agent-oriented video surveillance system (VSS. An intruder handling scenario is designed and implemented through AOM. AOM provides an alternative method to engineer a distributed security system in a systematic manner. It presents the security system at a holistic view; provides a better conceptualization of agent-oriented security system and supports rapid prototyping as well as simulation of video surveillance system.

  16. Low-cost panoramic infrared surveillance system

    Science.gov (United States)

    Kecskes, Ian; Engel, Ezra; Wolfe, Christopher M.; Thomson, George

    2017-05-01

    A nighttime surveillance concept consisting of a single surface omnidirectional mirror assembly and an uncooled Vanadium Oxide (VOx) longwave infrared (LWIR) camera has been developed. This configuration provides a continuous field of view spanning 360° in azimuth and more than 110° in elevation. Both the camera and the mirror are readily available, off-the-shelf, inexpensive products. The mirror assembly is marketed for use in the visible spectrum and requires only minor modifications to function in the LWIR spectrum. The compactness and portability of this optical package offers significant advantages over many existing infrared surveillance systems. The developed system was evaluated on its ability to detect moving, human-sized heat sources at ranges between 10 m and 70 m. Raw camera images captured by the system are converted from rectangular coordinates in the camera focal plane to polar coordinates and then unwrapped into the users azimuth and elevation system. Digital background subtraction and color mapping are applied to the images to increase the users ability to extract moving items from background clutter. A second optical system consisting of a commercially available 50 mm f/1.2 ATHERM lens and a second LWIR camera is used to examine the details of objects of interest identified using the panoramic imager. A description of the components of the proof of concept is given, followed by a presentation of raw images taken by the panoramic LWIR imager. A description of the method by which these images are analyzed is given, along with a presentation of these results side-by-side with the output of the 50 mm LWIR imager and a panoramic visible light imager. Finally, a discussion of the concept and its future development are given.

  17. Sustainable Monitoring and Surveillance Systems to Improve HIV Programs: Review.

    Science.gov (United States)

    Low-Beer, Daniel; Mahy, Mary; Renaud, Francoise; Calleja, Txema

    2018-04-24

    HIV programs have provided a major impetus for investments in surveillance data, with 5-10% of HIV program budgets recommended to support data. However there are questions concerning the sustainability of these investments. The Sustainable Development Goals have consolidated health into one goal and communicable diseases into one target (Target 3.3). Sustainable Development Goals now introduce targets focused specifically on data (Targets 17.18 and 17.19). Data are seen as one of the three systemic issues (in Goal 17) for implementing Sustainable Development Goals, alongside policies and partnerships. This paper reviews the surveillance priorities in the context of the Sustainable Development Goals and highlights the shift from periodic measurement towards sustainable disaggregated, real-time, case, and patient data, which are used routinely to improve programs. Finally, the key directions in developing person-centered monitoring systems are assessed with country examples. The directions contribute to the Sustainable Development Goal focus on people-centered development applied to data. ©Daniel Low-Beer, Mary Mahy, Francoise Renaud, Txema Calleja. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 24.04.2018.

  18. Converging requirements and emerging challenges to public health diseases surveillance and bio surveillance

    International Nuclear Information System (INIS)

    Rao, V.; Abel, T.

    2009-01-01

    Disease surveillance systems are a critical component of an early warning system for public health agencies to prepare and respond to major public health catastrophes. With a growing emphasis for more robust early indicator and warning systems to track emerging and dangerous diseases of suspicious nature, considerable emphasis is now placed on deployment of more expanded electronic disease surveillance systems. The architectural considerations for bio surveillance information system are based on collection, analysis and dissemination of human, veterinary and agricultural related disease surveillance to broader regional areas likely to be affected in the event of an emerging disease, or due to bioterrorism and better coordinate plans, preparations and response by governmental agencies and multilateral forums. The diseases surveillance systems architectures by intent and design could as well support biological threat monitoring and threat reduction initiatives. As an illustrative sample set, this paper will describe the comparative informatics requirements for a disease surveillance systems developed by CSC for the US Centers for Diseases Control and Prevention (CDC) currently operational nationwide, and biological weapons threat assessment developed as part of the Threat Agent Detection and Response (TADR) Network under the US Biological Threat Reduction Program and deployed at Uzbekistan, Kazakhstan, Georgia, and Azerbaijan.(author)

  19. Implementation of nuclear material surveillance system based on the digital video capture card and counter

    International Nuclear Information System (INIS)

    Lee, Sang Yoon; Song, Dae Yong; Ko, Won Il; Ha, Jang Ho; Kim, Ho Dong

    2003-07-01

    In this paper, the implementation techniques of nuclear material surveillance system based on the digital video capture board and digital counter was described. The surveillance system that is to be developed is consist of CCD cameras, neutron monitors, and PC for data acquisition. To develop the system, the properties of the PCI based capture board and counter was investigated, and the characteristics of related SDK library was summarized. This report could be used for the developers who want to develop the surveillance system for various experimental environments based on the DVR and sensors using Borland C++ Builder

  20. INVIS : Integrated night vision surveillance and observation system

    NARCIS (Netherlands)

    Toet, A.; Hogervorst, M.A.; Dijk, J.; Son, R. van

    2010-01-01

    We present the design and first field trial results of the all-day all-weather INVIS Integrated Night Vision surveillance and observation System. The INVIS augments a dynamic three-band false-color nightvision image with synthetic 3D imagery in a real-time display. The night vision sensor suite

  1. Proposal of a framework for evaluating military surveillance systems for early detection of outbreaks on duty areas

    Directory of Open Access Journals (Sweden)

    Webber Daniel

    2008-04-01

    Full Text Available Abstract Background In recent years a wide variety of epidemiological surveillance systems have been developed to provide early identification of outbreaks of infectious disease. Each system has had its own strengths and weaknesses. In 2002 a Working Group of the Centers for Disease Control and Prevention (CDC produced a framework for evaluation, which proved suitable for many public health surveillance systems. However this did not easily adapt to the military setting, where by necessity a variety of different parameters are assessed, different constraints placed on the systems, and different objectives required. This paper describes a proposed framework for evaluation of military syndromic surveillance systems designed to detect outbreaks of disease on operational deployments. Methods The new framework described in this paper was developed from the cumulative experience of British and French military syndromic surveillance systems. The methods included a general assessment framework (CDC, followed by more specific methods of conducting evaluation. These included Knowledge/Attitude/Practice surveys (KAP surveys, technical audits, ergonomic studies, simulations and multi-national exercises. A variety of military constraints required integration into the evaluation. Examples of these include the variability of geographical conditions in the field, deployment to areas without prior knowledge of naturally-occurring disease patterns, the differences in field sanitation between locations and over the length of deployment, the mobility of military forces, turnover of personnel, continuity of surveillance across different locations, integration with surveillance systems from other nations working alongside each other, compatibility with non-medical information systems, and security. Results A framework for evaluation has been developed that can be used for military surveillance systems in a staged manner consisting of initial, intermediate and final

  2. Using Surveillance Camera Systems to Monitor Public Domains: Can Abuse Be Prevented

    Science.gov (United States)

    2006-03-01

    relationship with a 16-year old girl failed. The incident was captured by a New York City Police Department surveillance camera. Although the image...administrators stated that the images recorded were “…nothing more than images of a few bras and panties .”17 The use of CCTV surveillance systems for

  3. Surveillance system using the CCTV at the fuel transfer pond in the Tokai reprocessing plant

    International Nuclear Information System (INIS)

    Hayakawa, T.; Fukuhara, J.; Ochiai, K.; Ohnishi, T.; Ogata, Y.; Okamoto, H.

    1991-01-01

    The Fuel Transfer Pond (FTP) in the Tokai Reprocessing Plant (TRP) is a strategic point for safeguards. Spent fuels, therefore, in the FTP have been surveyed by the surveillance system using the underwater CCTV. This system was developed through the improvement of devices composed of cameras and VCRs and the provision of tamper resistance function as one of the JASPAS (Japan Support Program for Agency Safeguards) program. The purpose of this program is to realize the continuous surveillance of the slanted tunnel through which the spent fuel on the conveyor is moved from the FTP to the Mechanical Processing Cell (MPC). This paper reports that, when this surveillance system is applied to an inspection device, the following requirements are needed: To have the ability of continuous and unattended surveillance of the spent fuel on the conveyor path from the FTP to the MPC; To have the tamper resistance function for continuous and unattended surveillance of the spent fuel

  4. A demonstrator for an integrated subway protection system

    Science.gov (United States)

    Detoma, E.; Capetti, P.; Casati, G.; Billington, S.

    2008-04-01

    In 2006 SEPA has carried on the installation and tests of a demonstrator for an integrated subway protection system at a new subway station in the Naples, Italy) metropolitan area. Protection of a subway system is a difficult task given the amount of passengers transported every day. The demonstrator has been limited to non-intrusive detection techniques not to impair the passenger flow into the station. The demonstrator integrates several technologies and products that have been developed by SEPA or are already available on the market (MKS Instruments,...). The main purpose is to provide detection capabilities for attempts to introduce radioactive substances in the subway station, in order to foil possible attempts to place a dirty bomb, and threat detection and identification following release of chemical agents. The system integrates additional sensors such as video surveillance cameras and air flow sensing to complement the basic sensors suite. The need to protect sensitive installations such as subway stations has been highlighted by the series of terroristics actions carried out in recent years in the subway in London. However, given the number of passengers of a metro system, it is impossible to propose security techniques operating in ways similar to the screening of passengers in airports. Passengers screening and threat detection and identification must be quick, non-intrusive and capable of screening a large number of passengers to be applicable to mass transit systems. In 2005 SEPA, a small company operating in the field of trains video-surveillance systems and radiation detectors, started developing an integrated system to provide a comprehensive protection to subway stations, based on ready available or off-the-shelf components in order to quickly develop a reliable system with available technology. We ruled out at the beginning any new development in order to speed up the fielding of the system in less than one year. The system was developed with

  5. The integrated proactive surveillance system for prostate cancer.

    Science.gov (United States)

    Wang, Haibin; Yatawara, Mahendra; Huang, Shao-Chi; Dudley, Kevin; Szekely, Christine; Holden, Stuart; Piantadosi, Steven

    2012-01-01

    In this paper, we present the design and implementation of the integrated proactive surveillance system for prostate cancer (PASS-PC). The integrated PASS-PC is a multi-institutional web-based system aimed at collecting a variety of data on prostate cancer patients in a standardized and efficient way. The integrated PASS-PC was commissioned by the Prostate Cancer Foundation (PCF) and built through the joint of efforts by a group of experts in medical oncology, genetics, pathology, nutrition, and cancer research informatics. Their main goal is facilitating the efficient and uniform collection of critical demographic, lifestyle, nutritional, dietary and clinical information to be used in developing new strategies in diagnosing, preventing and treating prostate cancer.The integrated PASS-PC is designed based on common industry standards - a three tiered architecture and a Service- Oriented Architecture (SOA). It utilizes open source software and programming languages such as HTML, PHP, CSS, JQuery, Drupal and MySQL. We also use a commercial database management system - Oracle 11g. The integrated PASS-PC project uses a "confederation model" that encourages participation of any interested center, irrespective of its size or location. The integrated PASS-PC utilizes a standardized approach to data collection and reporting, and uses extensive validation procedures to prevent entering erroneous data. The integrated PASS-PC controlled vocabulary is harmonized with the National Cancer Institute (NCI) Thesaurus. Currently, two cancer centers in the USA are participating in the integrated PASS-PC project.THE FINAL SYSTEM HAS THREE MAIN COMPONENTS: 1. National Prostate Surveillance Network (NPSN) website; 2. NPSN myConnect portal; 3. Proactive Surveillance System for Prostate Cancer (PASS-PC). PASS-PC is a cancer Biomedical Informatics Grid (caBIG) compatible product. The integrated PASS-PC provides a foundation for collaborative prostate cancer research. It has been built to

  6. The systems engineering design of a smart Forward Operating Base surveillance system for forward operating base protection

    OpenAIRE

    Craft, Timothy L.

    2013-01-01

    Approved for public release; distribution is unlimited Forward operating bases are vulnerable to terrorist activity due to their location and limited resources. Threat awareness under these conditions is paramount to the safety of the personnel and to mission accomplishment. In the absence of the manpower required to maintain complete and continuous monitoring of the FOBs surroundings, an automated surveillance system is needed. The Smart FOB Surveillance System (SFSS) employs a multi-agen...

  7. Evaluation of the enterovirus laboratory surveillance system in Denmark, 2010 to 2013

    DEFF Research Database (Denmark)

    Condell, Orla; Midgley, Sofie E; Christiansen, Claus Bohn

    2016-01-01

    The primary aim of the Danish enterovirus (EV) surveillance system is to document absence of poliovirus infection. The conflict in Syria has left many children unvaccinated and movement from areas with polio cases to Europe calls for increased awareness to detect and respond to virus-transmission......The primary aim of the Danish enterovirus (EV) surveillance system is to document absence of poliovirus infection. The conflict in Syria has left many children unvaccinated and movement from areas with polio cases to Europe calls for increased awareness to detect and respond to virus......-transmission in a timely manner. We evaluate the national EV laboratory surveillance, to generate recommendations for system strengthening. The system was analysed for completeness of viral typing analysis and clinical information and timeliness of specimen collection, laboratory results and reporting of clinical...... information. Of 23,720 specimens screened, 2,202 (9.3%) were EV-positive. Submission of cerebrospinal fluid and faecal specimens from primary diagnostic laboratories was 79.5% complete (845/1,063), and varied by laboratory and patient age. EV genotypes were determined in 68.5% (979/1,430) of laboratory...

  8. Regional Disease Surveillance Meeting - Final Paper

    Energy Technology Data Exchange (ETDEWEB)

    Lesperance, Ann M.; Mahy, Heidi A.

    2006-08-08

    On June 1, 2006, public health officials working in surveillance, epidemiological modeling, and information technology communities from the Seattle/Tacoma area and State of Washington met with members of the Pacific Northwest National Laboratory (PNNL) to discuss the current state of disease surveillance and gaps and needs to improve the current systems. The meeting also included a discussion of PNNL initiatives that might be appropriate to enhance disease surveillance and the current tools being used for disease surveillance. Participants broke out into two groups to identify critical gaps and needs for improving a surveillance system, and discuss the requirements for developing improved surveillance. Each group developed a list of key priorities summarizing the requirements for improved surveillance. The objective of this meeting was to work towards the development of an improved disease surveillance system.

  9. SCORPIO: a framework for core surveillance systems

    International Nuclear Information System (INIS)

    Berg, Oe.; Tsuiki, Makoto

    1999-01-01

    The first version of the core surveillance system SCORPIO was installed at Unit 2, Ringhals, in 1984. It was implemented on Norsk Data mini-computers with a fully graphical user-interface. The main purpose was to provide a practical tool for reactor operators and reactor physicists for on-line monitoring and predictive analysis of core behaviour. A second version of SCORPIO was developed in 1993-1995 and implemented on Unix workstations. In addition to upgrading the system at Ringhals, the system was installed by Duke Power, USA, on 7 reactors. SCORPIO was also installed on the Sizewell B reactor. Recently a new framework has been developed which further enhances the flexibility and capabilities for implementing core surveillance systems in different types of nuclear power plants. Modules can be added and replaced in an easy manner. It allows fast and reliable communication of data between modules based on the Software Bus tool developed by IFE. Further, the Picasso-3 user interface management system supports efficient implementation of different user interfaces. Both Unix and Windows NT platforms are supported. The new framework has been applied in development and installation of a SCORPIO-VVER version for the Dukovany NPP, Czech Republic. Here it was of particular importance to provide a flexible system for integration of modules originating from different companies. Development of a BWR version is now in progress. This means that SCORPIO will be available for all the major reactor types, and synergy is obtained by application of a common framework both with respect to system implementation and maintenance. By using the SCORPIO framework, the development time is reduced and the maintenance work is carried out more efficiently, compared to developing systems with lower-level tools. For instance, the MMI can be developed and tested independently of the physics modules

  10. Parallel Computational Intelligence-Based Multi-Camera Surveillance System

    OpenAIRE

    Orts-Escolano, Sergio; Garcia-Rodriguez, Jose; Morell, Vicente; Cazorla, Miguel; Azorin-Lopez, Jorge; García-Chamizo, Juan Manuel

    2014-01-01

    In this work, we present a multi-camera surveillance system based on the use of self-organizing neural networks to represent events on video. The system processes several tasks in parallel using GPUs (graphic processor units). It addresses multiple vision tasks at various levels, such as segmentation, representation or characterization, analysis and monitoring of the movement. These features allow the construction of a robust representation of the environment and interpret the behavior of mob...

  11. A Master-Slave Surveillance System to Acquire Panoramic and Multiscale Videos

    Directory of Open Access Journals (Sweden)

    Yu Liu

    2014-01-01

    Full Text Available This paper describes a master-slave visual surveillance system that uses stationary-dynamic camera assemblies to achieve wide field of view and selective focus of interest. In this system, the fish-eye panoramic camera is capable of monitoring a large area, and the PTZ dome camera has high mobility and zoom ability. In order to achieve the precise interaction, preprocessing spatial calibration between these two cameras is required. This paper introduces a novel calibration approach to automatically calculate a transformation matrix model between two coordinate systems by matching feature points. In addition, a distortion correction method based on Midpoint Circle Algorithm is proposed to handle obvious horizontal distortion in the captured panoramic image. Experimental results using realistic scenes have demonstrated the efficiency and applicability of the system with real-time surveillance.

  12. Laser surveillance systems for fuel storage pools

    International Nuclear Information System (INIS)

    Boeck, H.

    1985-06-01

    A Laser Surveillance System (LASSY) as a new safeguards device has been developed under the IAEA research contract No. 3458/RB at the Atominstitut Wien using earlier results by S. Fiarman. This system is designed to act as a sheet of light covering spent fuel assemblies in spent fuel storage pools. When movement of assemblies takes place, LASSY detects and locates the position of the movement in the pool and when interrogated, presents a list of pool positions and times of movement to the safeguards inspector. A complete prototype system was developed and built. Full scale tests showed the principal working capabilities of a LASSY underwater

  13. Space Station Environmental Health System water quality monitoring

    Science.gov (United States)

    Vincze, Johanna E.; Sauer, Richard L.

    1990-01-01

    One of the unique aspects of the Space Station is that it will be a totally encapsulated environment and the air and water supplies will be reclaimed for reuse. The Environmental Health System, a subsystem of CHeCS (Crew Health Care System), must monitor the air and water on board the Space Station Freedom to verify that the quality is adequate for crew safety. Specifically, the Water Quality Subsystem will analyze the potable and hygiene water supplies regularly for organic, inorganic, particulate, and microbial contamination. The equipment selected to perform these analyses will be commercially available instruments which will be converted for use on board the Space Station Freedom. Therefore, the commercial hardware will be analyzed to identify the gravity dependent functions and modified to eliminate them. The selection, analysis, and conversion of the off-the-shelf equipment for monitoring the Space Station reclaimed water creates a challenging project for the Water Quality engineers and scientists.

  14. Aseismic foundation system for nuclear power stations

    International Nuclear Information System (INIS)

    Jolivet, F.; Richli, M.

    1977-01-01

    The aseismic foundation system, as described in this paper, is a new development, which makes it possible to build standard nuclear power stations in areas exposed to strong earthquakes. By adopting proven engineering concepts in design and construction of components, great advantages are achieved in the following areas: safety and reliability; efficiency; design schedule; cost. The need for an aseismic foundation system will arise more and more, as a large part of nuclear power station sites are located in highly seismic zones or must meet high intensity earthquake criteria due to the lack of historic data. (Auth.)

  15. 47 CFR 73.6025 - Antenna system and station location.

    Science.gov (United States)

    2010-10-01

    ... RADIO BROADCAST SERVICES Class A Television Broadcast Stations § 73.6025 Antenna system and station... clearly the radiation characteristics of the antenna above and below the horizontal plane. In cases where...

  16. Violence Against Children Surveys (VACS): towards a global surveillance system.

    Science.gov (United States)

    Chiang, Laura F; Kress, Howard; Sumner, Steven A; Gleckel, Jessie; Kawemama, Philbert; Gordon, Rebecca N

    2016-04-01

    To describe the Violence Against Children Surveys (VACS). The survey is a national, household survey that systematically measures the prevalence, nature and consequences of sexual, physical and emotional violence against children. This report provides information about the history, implementation, ethical protections, utility, results, limitations, and future directions of the VACS work. The study has been implemented in 11 countries in Africa, Asia and the Caribbean, providing each of these countries with baseline data and momentum to address violence against children as a public health and human rights priority. These data are novel in each country, and VACS is well poised to contribute to an existing surveillance system or be used as the basis of a periodic surveillance system. Without ongoing surveillance to assess prevalence and the impact of policy, prevention and response programming, violence will likely continue to be overlooked as the linchpin public health crisis that it is, globally and in individual countries. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Evaluating the electronic tuberculosis register surveillance system in Eden District, Western Cape, South Africa, 2015.

    Science.gov (United States)

    Mlotshwa, Mandla; Smit, Sandra; Williams, Seymour; Reddy, Carl; Medina-Marino, Andrew

    2017-01-01

    Tuberculosis (TB) surveillance data are crucial to the effectiveness of National TB Control Programs. In South Africa, few surveillance system evaluations have been undertaken to provide a rigorous assessment of the platform from which the national and district health systems draws data to inform programs and policies. Evaluate the attributes of Eden District's TB surveillance system, Western Cape Province, South Africa. Data quality, sensitivity and positive predictive value were assessed using secondary data from 40,033 TB cases entered in Eden District's ETR.Net from 2007 to 2013, and 79 purposively selected TB Blue Cards (TBCs), a medical patient file and source document for data entered into ETR.Net. Simplicity, flexibility, acceptability, stability and usefulness of the ETR.Net were assessed qualitatively through interviews with TB nurses, information health officers, sub-district and district coordinators involved in the TB surveillance. TB surveillance system stakeholders report that Eden District's ETR.Net system was simple, acceptable, flexible and stable, and achieves its objective of informing TB control program, policies and activities. Data were less complete in the ETR.Net (66-100%) than in the TBCs (76-100%), and concordant for most variables except pre-treatment smear results, antiretroviral therapy (ART) and treatment outcome. The sensitivity of recorded variables in ETR.Net was 98% for gender, 97% for patient category, 93% for ART, 92% for treatment outcome and 90% for pre-treatment smear grading. Our results reveal that the system provides useful information to guide TB control program activities in Eden District. However, urgent attention is needed to address gaps in clinical recording on the TBC and data capturing into the ETR.Net system. We recommend continuous training and support of TB personnel involved with TB care, management and surveillance on TB data recording into the TBCs and ETR.Net as well as the implementation of a well

  18. Airborne and Maritime/Fixed Station Joint Tactical Radio System (AMF JTRS)

    Science.gov (United States)

    2015-12-01

    Selected Acquisition Report (SAR) RCS: DD-A&T(Q&A)823-421 Airborne & Maritime/Fixed Station Joint Tactical Radio System (AMF JTRS) As of FY 2017...Information Program Name Airborne & Maritime/Fixed Station Joint Tactical Radio System (AMF JTRS) DoD Component Army Responsible Office References SAR...UNCLASSIFIED 5 Mission and Description Airborne & Maritime/Fixed Station Joint Tactical Radio System (AMF JTRS) products are software programmable

  19. Technical Specifications, Braidwood Station, Unit Nos. 1 and 2 (Docket Nos. STN 50-456 and STN 50-457). Appendix ''A'' to License No. NPF-59

    International Nuclear Information System (INIS)

    1986-10-01

    Information is presented for Braidwood Station Unit Nos. 1 and 2 in the areas of: safety limits and limiting safety system settings; limiting conditions for operation and surveillance requirements; design features; and administrative controls

  20. Global Tobacco Surveillance System (GTSS) - Global Adult Tobacco Survey (GATS)

    Data.gov (United States)

    U.S. Department of Health & Human Services — 2008-2012. Centers for Disease Control and Prevention (CDC). Office on Smoking and Health (OSH) – Global Tobacco Surveillance System (GTSS) - Global Adult Tobacco...

  1. Nutrition, Physical Activity, and Obesity - Youth Risk Behavior Surveillance System

    Data.gov (United States)

    U.S. Department of Health & Human Services — This dataset includes data on adolescent's diet, physical activity, and weight status from Youth Risk Behavior Surveillance System (YRBSS). This data is used for...

  2. Potentialities and type of integrating nuclear heating stations into district heating systems

    International Nuclear Information System (INIS)

    Munser, H.; Reetz, B.; Schmidt, G.

    1978-01-01

    Technical and economical potentialities of applying nuclear heating stations in district heating systems are discussed considering the conditions of the GDR. Special attention is paid to an optimum combination of nuclear heating stations with heat sources based on organic fuels. Optimum values of the contribution of nuclear heating stations to such combined systems and the economic power range of nuclear heating stations are estimated. Final considerations are concerned with the effect of siting and safety concepts of nuclear heating stations on the structure of the district heating system. (author)

  3. Reliability models for Space Station power system

    Science.gov (United States)

    Singh, C.; Patton, A. D.; Kim, Y.; Wagner, H.

    1987-01-01

    This paper presents a methodology for the reliability evaluation of Space Station power system. The two options considered are the photovoltaic system and the solar dynamic system. Reliability models for both of these options are described along with the methodology for calculating the reliability indices.

  4. Extracting foreground ensemble features to detect abnormal crowd behavior in intelligent video-surveillance systems

    Science.gov (United States)

    Chan, Yi-Tung; Wang, Shuenn-Jyi; Tsai, Chung-Hsien

    2017-09-01

    Public safety is a matter of national security and people's livelihoods. In recent years, intelligent video-surveillance systems have become important active-protection systems. A surveillance system that provides early detection and threat assessment could protect people from crowd-related disasters and ensure public safety. Image processing is commonly used to extract features, e.g., people, from a surveillance video. However, little research has been conducted on the relationship between foreground detection and feature extraction. Most current video-surveillance research has been developed for restricted environments, in which the extracted features are limited by having information from a single foreground; they do not effectively represent the diversity of crowd behavior. This paper presents a general framework based on extracting ensemble features from the foreground of a surveillance video to analyze a crowd. The proposed method can flexibly integrate different foreground-detection technologies to adapt to various monitored environments. Furthermore, the extractable representative features depend on the heterogeneous foreground data. Finally, a classification algorithm is applied to these features to automatically model crowd behavior and distinguish an abnormal event from normal patterns. The experimental results demonstrate that the proposed method's performance is both comparable to that of state-of-the-art methods and satisfies the requirements of real-time applications.

  5. MORTICIA, a statistical analysis software package for determining optical surveillance system effectiveness.

    Science.gov (United States)

    Ramkilowan, A.; Griffith, D. J.

    2017-10-01

    Surveillance modelling in terms of the standard Detect, Recognise and Identify (DRI) thresholds remains a key requirement for determining the effectiveness of surveillance sensors. With readily available computational resources it has become feasible to perform statistically representative evaluations of the effectiveness of these sensors. A new capability for performing this Monte-Carlo type analysis is demonstrated in the MORTICIA (Monte- Carlo Optical Rendering for Theatre Investigations of Capability under the Influence of the Atmosphere) software package developed at the Council for Scientific and Industrial Research (CSIR). This first generation, python-based open-source integrated software package, currently in the alpha stage of development aims to provide all the functionality required to perform statistical investigations of the effectiveness of optical surveillance systems in specific or generic deployment theatres. This includes modelling of the mathematical and physical processes that govern amongst other components of a surveillance system; a sensor's detector and optical components, a target and its background as well as the intervening atmospheric influences. In this paper we discuss integral aspects of the bespoke framework that are critical to the longevity of all subsequent modelling efforts. Additionally, some preliminary results are presented.

  6. Nutrition, Physical Activity, and Obesity - Behavioral Risk Factor Surveillance System

    Data.gov (United States)

    U.S. Department of Health & Human Services — This dataset includes data on adult's diet, physical activity, and weight status from Behavioral Risk Factor Surveillance System. This data is used for DNPAO's Data,...

  7. Evaluation of a Spotted Fever Group Rickettsia Public Health Surveillance System in Tennessee.

    Science.gov (United States)

    Fill, Mary-Margaret A; Moncayo, Abelardo C; Bloch, Karen C; Dunn, John R; Schaffner, William; Jones, Timothy F

    2017-09-01

    Spotted fever group (SFG) rickettsioses are endemic in Tennessee, with ∼2,500 cases reported during 2000-2012. Because of this substantial burden of disease, we performed a three-part evaluation of Tennessee's routine surveillance for SFG rickettsioses cases and deaths to assess the system's effectiveness. Tennessee Department of Health (TDH) SFG rickettsioses surveillance records were matched to three patient series: 1) patients with positive serologic specimens from a commercial reference laboratory during 2010-2011, 2) tertiary medical center patients with positive serologic tests during 2007-2013, and 3) patients identified from death certificates issued during 1995-2014 with SFG rickettsiosis-related causes of death. Chart reviews were performed and patients were classified according to the Council of State and Territorial Epidemiologists' case definition. Of 254 SFG Rickettsia -positive serologic specimens from the reference laboratory, 129 (51%) met the case definition for confirmed or probable cases of rickettsial disease after chart review. The sensitivity of the TDH surveillance system to detect cases was 45%. Of the 98 confirmed or probable cases identified from the medical center, the sensitivity of the TDH surveillance system to detect cases was 34%. Of 27 patients identified by death certificates, 12 (44%) were classified as confirmed or probable cases; four (33%) were reported to TDH, but none were correctly identified as deceased. Cases of SFG rickettsioses were underreported and fatalities not correctly identified. Efforts are needed to improve SFG rickettsiosis surveillance in Tennessee.

  8. Ontario Hydro Pickering Generating Station fuel handling system performance

    International Nuclear Information System (INIS)

    Underhill, H.J.

    1986-01-01

    The report briefly describes the Pickering Nuclear Generating Station (PNGS) on-power fuel handling system and refuelling cycle. Lifetime performance parameters of the fuelling system are presented, including station incapability charged to the fuel handling system, cost of operating and maintenance, dose expenditure, events causing system unavailability, maintenance and refuelling strategy. It is concluded that the 'CANDU' on-power fuelling system, by consistently contributing less than 1% to the PNGS incapability, has been credited with a 6 to 20% increase in reactor capacity factor, compared to off-power fuelling schemes. (author)

  9. Involving private healthcare practitioners in an urban NCD sentinel surveillance system: lessons learned from Pune, India.

    Science.gov (United States)

    Kroll, Mareike; Phalkey, Revati; Dutta, Sayani; Shukla, Sharvari; Butsch, Carsten; Bharucha, Erach; Kraas, Frauke

    2016-01-01

    Despite the rising impact of non-communicable diseases (NCDs) on public health in India, lack of quality data and routine surveillance hampers the planning process for NCD prevention and control. Current surveillance programs focus largely on communicable diseases and do not adequately include the private healthcare sector as a major source of care in cities. The objective of the study was to conceptualize, implement, and evaluate a prototype for an urban NCD sentinel surveillance system among private healthcare practitioners providing primary care in Pune, India. We mapped all private healthcare providers in three selected areas of the city, conducted a knowledge, attitude, and practice survey with regard to surveillance among 258 consenting practitioners, and assessed their willingness to participate in a routine NCD surveillance system. In total, 127 practitioners agreed and were included in a 6-month surveillance study. Data on first-time diagnoses of 10 selected NCDs alongside basic demographic and socioeconomic patient information were collected onsite on a monthly basis using a paper-based register. Descriptive and regression analyses were performed. In total, 1,532 incident cases were recorded that mainly included hypertension ( n =622, 41%) and diabetes ( n =460, 30%). Dropout rate was 10% ( n =13). The monthly reporting consistency was quite constant, with the majority ( n =63, 50%) submitting 1-10 cases in 6 months. Average number of submitted cases was highest among allopathic practitioners (17.4). A majority of the participants ( n =104, 91%) agreed that the surveillance design could be scaled up to cover the entire city. The study indicates that private primary healthcare providers (allopathic and alternate medicine practitioners) play an important role in the diagnosis and treatment of NCDs and can be involved in NCD surveillance, if certain barriers are addressed. Main barriers observed were lack of regulation of the private sector, cross

  10. FCA containment and surveillance (C/S) system

    International Nuclear Information System (INIS)

    Ogawa, Hironobu; Mukaiyama, Takehiko; Yokota, Yasuhiro.

    1994-11-01

    The Fast Critical Assembly (FCA) facility of the Japan Atomic Energy Research Inst. (JAERI) is internationally recognized as one of the most sensitive facility in the world from the viewpoint of international safeguards, because the facility possesses a large amount of metallic uranium and metallic plutonium, which are needed to perform various physical experiments. These material are subject to frequent verifications by the inspectorate, the International Atomic Energy Agency (IAEA) and the domestic authority (Science and Technology Agency of Japan, STA). Those verifications require inspectors to access to these materials for measurements and applications of seals. Human resources increase of irradiations and restrictions on the freedom of physical experiments, that are inevitably associated with these inspection activities, have been a serious problem that causes significant burdens for all relating parties. To decrease these burdens without any confliction with the inspection goals, an advanced comprehensive system of containment and surveillance has been developed. The FCA Containment and Surveillance (C/S) System consists of tow independent subsystems, i. e. Portal Monitor (P/M) and Penetration Monitor(PN/M). In this system the internal wall of the reactor building is used as a part of containment for the safeguards purpose, which enables the portal, that is installed at the internal wall of the reactor building, to be used as an area for monitoring of any removal of nuclear material. A metal detector of high sensitivity has been selected for the system since all nuclear materials possessed by the FCA has metallic forms. The internal wall has several penetrations for utility purposes, which should also be monitored for the purpose of detecting any removal of nuclear material from the reactor core area. A penetration monitor system has been developed for this purpose. This report describes functions of the system and their operation procedures. (author)

  11. Automated surveillance system for hospital-acquired urinary tract infections in Denmark

    DEFF Research Database (Denmark)

    Condell, Orla; Gubbels, Sophie; Nielsen, J

    2016-01-01

    BACKGROUND: The Danish Hospital-Acquired Infections Database (HAIBA) is an automated surveillance system using hospital administrative, microbiological, and antibiotic medication data. AIM: To define and evaluate the case definition for hospital-acquired urinary tract infection (HA-UTI) and to de......BACKGROUND: The Danish Hospital-Acquired Infections Database (HAIBA) is an automated surveillance system using hospital administrative, microbiological, and antibiotic medication data. AIM: To define and evaluate the case definition for hospital-acquired urinary tract infection (HA-UTI......) and to describe surveillance data from 2010 to 2014. METHODS: The HA-UTI algorithm defined a laboratory-diagnosed UTI as a urine culture positive for no more than two micro-organisms with at least one at ≥10(4)cfu/mL, and a probable UTI as a negative urine culture and a relevant diagnosis code or antibiotic...... treatment. UTI was considered hospital-acquired if a urine sample was collected ≥48h after admission and UTI was calculated per 10,000 risk-days. For validation, prevalence was calculated for each day and compared to point prevalence survey (PPS) data. FINDINGS: HAIBA...

  12. Design, Implementation, and Evaluation of the Adolescents and Surveillance System for the Obesity Prevention Project.

    Science.gov (United States)

    Tabacchi, Garden; Bianco, Antonino; Alessi, Nicola; Filippi, Anna Rita; Napoli, Giuseppe; Jemni, Monèm; Censi, Laura; Breda, João; Schumann, Nathali Lehmann; Firenze, Alberto; Vitale, Francesco; Mammina, Caterina

    2016-03-01

    The Adolescents Surveillance System for Obesity prevention (ASSO) Project aimed at developing standardized and web-based tools for collecting data on adolescents' obesity and its potential determinants. This has been implemented and piloted in the local area of Palermo city, Italy. The aim of the present study is to provide an overview of the Project's design, implementation, and evaluation, highlighting all the aspects for a potential scale-up of the surveillance system on the whole national territory and abroad, as a sustainable and effective source of data.The overall structure and management, the ASSO-toolkit, the ASSO-NutFit software, and all developed and used procedures for recruiting, training, and data collecting/analyzing are addressed. An interim evaluation has been performed through a feasibility study; a final Project evaluation has been performed reporting the Strengths, Weaknesses, Opportunities, and Threats (SWOT) and the attributes that a surveillance system should have.This article provides a detailed overview of the Project and highlights that ASSO can be considered a valid, logical, coherent, efficient, and sustainable surveillance system that is consistent with countries' needs and priorities.The system developed by the ASSO Project provides high-quality data and complies with several characteristics typical of a suitable surveillance system. It has a potential of being adopted within the National Health Service and other countries' Health Services for monitoring adolescents' obesity and its determinants, such as food intakes, behaviors, physical activity, and fitness profiles.

  13. A Smart Card-Based Electronic School Absenteeism System for Influenza-Like Illness Surveillance in Hong Kong: Design, Implementation, and Feasibility Assessment.

    Science.gov (United States)

    Ip, Dennis Km; Lau, Eric Hy; So, Hau Chi; Xiao, Jingyi; Lam, Chi Kin; Fang, Vicky J; Tam, Yat Hung; Leung, Gabriel M; Cowling, Benjamin J

    2017-10-06

    School-aged children have the highest incidence of respiratory virus infections each year, and transmission of respiratory viruses such as influenza virus can be a major concern in school settings. School absenteeism data have been employed as a component of influenza surveillance systems in some locations. Data timeliness and system acceptance remain as key determinants affecting the usefulness of a prospective surveillance system. The aim of this study was to assess the feasibility of implementing an electronic school absenteeism surveillance system using smart card-based technology for influenza-like illness (ILI) surveillance among a representative network of local primary and secondary schools in Hong Kong. We designed and implemented a surveillance system according to the Protocol for a Standardized information infrastructure for Pandemic and Emerging infectious disease Response (PROSPER). We employed an existing smart card-based education and school administration platform for data capture, customized the user interface, and used additional back end systems built for other downstream surveillance steps. We invited local schools to participate and collected absenteeism data by the implemented system. We compared temporal trend of the absenteeism data with data from existing community sentinel and laboratory surveillance data. We designed and implemented an ILI surveillance system utilizing smart card-based attendance tracking approach for data capture. We implemented the surveillance system in a total of 107 schools (including 66 primary schools and 41 secondary schools), covering a total of 75,052 children. The system successfully captured information on absences for 2 consecutive academic years (2012-2013 and 2013-2014). The absenteeism data we collected from the system reflected ILI activity in the community, with an upsurge in disease activity detected up to 1 to 2 weeks preceding other existing surveillance systems. We designed and implemented a novel

  14. Replicas Strategy and Cache Optimization of Video Surveillance Systems Based on Cloud Storage

    Directory of Open Access Journals (Sweden)

    Rongheng Li

    2018-04-01

    Full Text Available With the rapid development of video surveillance technology, especially the popularity of cloud-based video surveillance applications, video data begins to grow explosively. However, in the cloud-based video surveillance system, replicas occupy an amount of storage space. Also, the slow response to video playback constrains the performance of the system. In this paper, considering the characteristics of video data comprehensively, we propose a dynamic redundant replicas mechanism based on security levels that can dynamically adjust the number of replicas. Based on the location correlation between cameras, this paper also proposes a data cache strategy to improve the response speed of data reading. Experiments illustrate that: (1 our dynamic redundant replicas mechanism can save storage space while ensuring data security; (2 the cache mechanism can predict the playback behaviors of the users in advance and improve the response speed of data reading according to the location and time correlation of the front-end cameras; and (3 in terms of cloud-based video surveillance, our proposed approaches significantly outperform existing methods.

  15. Final report : mobile surveillance and wireless communication systems field operational test. Volume 1, Executive summary

    Science.gov (United States)

    1999-03-01

    This study focused on assessing the application of traffic monitoring and management systems which use transportable surveillance and ramp meter trailers, video image processors, and wireless communications. The mobile surveillance and wireless commu...

  16. An Operations Management System for the Space Station

    Science.gov (United States)

    Rosenthal, H. G.

    1986-09-01

    This paper presents an overview of the conceptual design of an integrated onboard Operations Management System (OMS). Both hardware and software concepts are presented and the integrated space station network is discussed. It is shown that using currently available software technology, an integrated software solution for Space Station management and control, implemented with OMS software, is feasible.

  17. Evaluation of cholera surveillance system in Osu Klottey District, Accra, Ghana (2011-2013).

    Science.gov (United States)

    Adjei, Eric Yirenkyi; Malm, Keziah Laurencia; Mensah, Kofi Nyarko; Sackey, Samuel Oko; Ameme, Donne; Kenu, Ernest; Abdulai, Marijanatu; Mills, Richael; Afari, Edwin

    2017-01-01

    Cholera is an acute illness characterized by profuse watery diarrhea. It is caused by vibrio cholera subgroup 01 and 0139. Rapid administration of fluid replacement therapy and supportive treatment can reduce mortality to around 1%. By the close of 2011, 10,628 cases and 100 deaths were reported in Ghana with a case fatality rate of 0.99. It is important to evaluate the cholera surveillance system in Ghana to determine if it is meeting its objective. The study was conducted in Osu Klottey district in the Accra Metropolitan area in January 2014. We assessed the operations (attributes and performance) of the surveillance system for cholera using CDC guidelines (2001). Surveillance data records at the district level from 2011-2013 were extracted and analyzed for frequency using Microsoft excel. Stakeholders and key informants were interviewed using structured questionnaire. Records were also reviewed at some health facilities and at district levels. In 2011 and 2012, case fatality rates (1.3% and 0.65%) respectively. Males were mostly affected. The most affected age group was 20-29. In 2011, Predictive value positive was 69.2% and 50% in 2012.Cholera peaked in March 2011 and April 2012. The Government of Ghana funded the system. The system is sensitive, simple, stable, flexible, acceptable and representative. It was also useful and data quality was relatively good. Predictive Value Positive was also good. The surveillance system is achieving its set out objectives. The system is sensitive, simple, stable, flexible, and acceptable. Predictive value positive was good.

  18. Using Acute Flaccid Paralysis Surveillance as a Platform for Vaccine-Preventable Disease Surveillance.

    Science.gov (United States)

    Wassilak, Steven G F; Williams, Cheryl L; Murrill, Christopher S; Dahl, Benjamin A; Ohuabunwo, Chima; Tangermann, Rudolf H

    2017-07-01

    Surveillance for acute flaccid paralysis (AFP) is a fundamental cornerstone of the global polio eradication initiative (GPEI). Active surveillance (with visits to health facilities) is a critical strategy of AFP surveillance systems for highly sensitive and timely detection of cases. Because of the extensive resources devoted to AFP surveillance, multiple opportunities exist for additional diseases to be added using GPEI assets, particularly because there is generally 1 district officer responsible for all disease surveillance. For this reason, integrated surveillance has become a standard practice in many countries, ranging from adding surveillance for measles and rubella to integrated disease surveillance for outbreak-prone diseases (integrated disease surveillance and response). This report outlines the current level of disease surveillance integration in 3 countries (Nepal, India, and Nigeria) and proposes that resources continue for long-term maintenance in resource-poor countries of AFP surveillance as a platform for surveillance of vaccine-preventable diseases and other outbreak-prone diseases. © The Author 2017. Published by Oxford University Press for the Infectious Diseases Society of America.

  19. Integrated design of intelligent surveillance systems and their user interface

    NARCIS (Netherlands)

    Toet, A.

    2005-01-01

    Modern complex surveillance systems consisting of multiple and heterogeneous sensors, automatic information registration and data analysis techniques, and decision support tools should provide the human operator an integrated, transparent and easily comprehensible view of the surveyed scene.

  20. Space Station tethered elevator system

    Science.gov (United States)

    Haddock, Michael H.; Anderson, Loren A.; Hosterman, K.; Decresie, E.; Miranda, P.; Hamilton, R.

    1989-01-01

    The optimized conceptual engineering design of a space station tethered elevator is presented. The tethered elevator is an unmanned, mobile structure which operates on a ten-kilometer tether spanning the distance between Space Station Freedom and a platform. Its capabilities include providing access to residual gravity levels, remote servicing, and transportation to any point along a tether. The report discusses the potential uses, parameters, and evolution of the spacecraft design. Emphasis is placed on the elevator's structural configuration and three major subsystem designs. First, the design of elevator robotics used to aid in elevator operations and tethered experimentation is presented. Second, the design of drive mechanisms used to propel the vehicle is discussed. Third, the design of an onboard self-sufficient power generation and transmission system is addressed.

  1. Euratom multi-camera optical surveillance system (EMOSS) - a digital solution

    International Nuclear Information System (INIS)

    Otto, P.; Wagner, H.G.; Taillade, B.; Pryck, C. de.

    1991-01-01

    In 1989 the Euratom Safeguards Directorate of the Commission of the European Communities drew up functional and draft technical specifications for a new fully digital multi-camera optical surveillance system. HYMATOM of Castries designed and built a prototype unit for laboratory and field tests. This paper reports and system design and first test results

  2. The Health and Occupation Research Network: An Evolving Surveillance System.

    Science.gov (United States)

    Carder, Melanie; Hussey, Louise; Money, Annemarie; Gittins, Matthew; McNamee, Roseanne; Stocks, Susan Jill; Sen, Dil; Agius, Raymond M

    2017-09-01

    Vital to the prevention of work-related ill-health (WRIH) is the availability of good quality data regarding WRIH burden and risks. Physician-based surveillance systems such as The Health and Occupation Research (THOR) network in the UK are often established in response to limitations of statutory, compensation-based systems for addressing certain epidemiological aspects of disease surveillance. However, to fulfil their purpose, THOR and others need to have methodologic rigor in capturing and ascertaining cases. This article describes how data collected by THOR and analogous systems can inform WRIH incidence, trends, and other determinants. An overview of the different strands of THOR research is provided, including methodologic advancements facilitated by increased data quantity/quality over time and the value of the research outputs for informing Government and other policy makers. In doing so, the utility of data collected by systems such as THOR to address a wide range of research questions, both in relation to WRIH and to wider issues of public and social health, is demonstrated.

  3. The Health and Occupation Research Network: An Evolving Surveillance System

    Directory of Open Access Journals (Sweden)

    Melanie Carder

    2017-09-01

    Full Text Available Vital to the prevention of work-related ill-health (WRIH is the availability of good quality data regarding WRIH burden and risks. Physician-based surveillance systems such as The Health and Occupation Research (THOR network in the UK are often established in response to limitations of statutory, compensation-based systems for addressing certain epidemiological aspects of disease surveillance. However, to fulfil their purpose, THOR and others need to have methodologic rigor in capturing and ascertaining cases. This article describes how data collected by THOR and analogous systems can inform WRIH incidence, trends, and other determinants. An overview of the different strands of THOR research is provided, including methodologic advancements facilitated by increased data quantity/quality over time and the value of the research outputs for informing Government and other policy makers. In doing so, the utility of data collected by systems such as THOR to address a wide range of research questions, both in relation to WRIH and to wider issues of public and social health, is demonstrated.

  4. Real-time wideband holographic surveillance system

    Science.gov (United States)

    Sheen, D.M.; Collins, H.D.; Hall, T.E.; McMakin, D.L.; Gribble, R.P.; Severtsen, R.H.; Prince, J.M.; Reid, L.D.

    1996-09-17

    A wideband holographic surveillance system including a transceiver for generating a plurality of electromagnetic waves; antenna for transmitting the electromagnetic waves toward a target at a plurality of predetermined positions in space; the transceiver also receiving and converting electromagnetic waves reflected from the target to electrical signals at a plurality of predetermined positions in space; a computer for processing the electrical signals to obtain signals corresponding to a holographic reconstruction of the target; and a display for displaying the processed information to determine nature of the target. The computer has instructions to apply a three dimensional backward wave algorithm. 28 figs.

  5. Wide area surveillance real-time motion detection systems

    CERN Document Server

    2014-01-01

    The book describes a system for visual surveillance using intelligent cameras. The camera uses robust techniques for detecting and tracking moving objects. The real time capture of the objects is then stored int he database. The tracking data stored in the database is analysed to study the camera view, detect and track objects, and study object behavior. These set of models provide a robust framework for coordinating the tracking of objects between overlapping and non-overlapping cameras, and recording the activity of objects detected by the system.

  6. Monitoring influenza activity in the United States: a comparison of traditional surveillance systems with Google Flu Trends.

    Directory of Open Access Journals (Sweden)

    Justin R Ortiz

    2011-04-01

    Full Text Available Google Flu Trends was developed to estimate US influenza-like illness (ILI rates from internet searches; however ILI does not necessarily correlate with actual influenza virus infections.Influenza activity data from 2003-04 through 2007-08 were obtained from three US surveillance systems: Google Flu Trends, CDC Outpatient ILI Surveillance Network (CDC ILI Surveillance, and US Influenza Virologic Surveillance System (CDC Virus Surveillance. Pearson's correlation coefficients with 95% confidence intervals (95% CI were calculated to compare surveillance data. An analysis was performed to investigate outlier observations and determine the extent to which they affected the correlations between surveillance data. Pearson's correlation coefficient describing Google Flu Trends and CDC Virus Surveillance over the study period was 0.72 (95% CI: 0.64, 0.79. The correlation between CDC ILI Surveillance and CDC Virus Surveillance over the same period was 0.85 (95% CI: 0.81, 0.89. Most of the outlier observations in both comparisons were from the 2003-04 influenza season. Exclusion of the outlier observations did not substantially improve the correlation between Google Flu Trends and CDC Virus Surveillance (0.82; 95% CI: 0.76, 0.87 or CDC ILI Surveillance and CDC Virus Surveillance (0.86; 95%CI: 0.82, 0.90.This analysis demonstrates that while Google Flu Trends is highly correlated with rates of ILI, it has a lower correlation with surveillance for laboratory-confirmed influenza. Most of the outlier observations occurred during the 2003-04 influenza season that was characterized by early and intense influenza activity, which potentially altered health care seeking behavior, physician testing practices, and internet search behavior.

  7. Monitoring Influenza Activity in the United States: A Comparison of Traditional Surveillance Systems with Google Flu Trends

    Science.gov (United States)

    Ortiz, Justin R.; Zhou, Hong; Shay, David K.; Neuzil, Kathleen M.; Fowlkes, Ashley L.; Goss, Christopher H.

    2011-01-01

    Background Google Flu Trends was developed to estimate US influenza-like illness (ILI) rates from internet searches; however ILI does not necessarily correlate with actual influenza virus infections. Methods and Findings Influenza activity data from 2003–04 through 2007–08 were obtained from three US surveillance systems: Google Flu Trends, CDC Outpatient ILI Surveillance Network (CDC ILI Surveillance), and US Influenza Virologic Surveillance System (CDC Virus Surveillance). Pearson's correlation coefficients with 95% confidence intervals (95% CI) were calculated to compare surveillance data. An analysis was performed to investigate outlier observations and determine the extent to which they affected the correlations between surveillance data. Pearson's correlation coefficient describing Google Flu Trends and CDC Virus Surveillance over the study period was 0.72 (95% CI: 0.64, 0.79). The correlation between CDC ILI Surveillance and CDC Virus Surveillance over the same period was 0.85 (95% CI: 0.81, 0.89). Most of the outlier observations in both comparisons were from the 2003–04 influenza season. Exclusion of the outlier observations did not substantially improve the correlation between Google Flu Trends and CDC Virus Surveillance (0.82; 95% CI: 0.76, 0.87) or CDC ILI Surveillance and CDC Virus Surveillance (0.86; 95%CI: 0.82, 0.90). Conclusions This analysis demonstrates that while Google Flu Trends is highly correlated with rates of ILI, it has a lower correlation with surveillance for laboratory-confirmed influenza. Most of the outlier observations occurred during the 2003–04 influenza season that was characterized by early and intense influenza activity, which potentially altered health care seeking behavior, physician testing practices, and internet search behavior. PMID:21556151

  8. Development of a Space Station Operations Management System

    Science.gov (United States)

    Brandli, A. E.; McCandless, W. T.

    To enhance the productivity of operations aboard the Space Station, a means must be provided to augment, and frequently to supplant, human effort in support of mission operations and management, both on the ground and onboard. The Operations Management System (OMS), under development at the Johnson Space Center, is one such means. OMS comprises the tools and procedures to facilitate automation of station monitoring, control, and mission planning tasks. OMS mechanizes, and hence rationalizes, execution of tasks traditionally performed by mission planners, the mission control center team, onboard System Management software, and the flight crew.

  9. Development of a Space Station Operations Management System

    Science.gov (United States)

    Brandli, A. E.; Mccandless, W. T.

    1988-01-01

    To enhance the productivity of operations aboard the Space Station, a means must be provided to augment, and frequently to supplant, human effort in support of mission operations and management, both on the ground and onboard. The Operations Management System (OMS), under development at the Johnson Space Center, is one such means. OMS comprises the tools and procedures to facilitate automation of station monitoring, control, and mission planning tasks. OMS mechanizes, and hence rationalizes, execution of tasks traditionally performed by mission planners, the mission control center team, onboard System Management software, and the flight crew.

  10. Daya Bay Nuclear Power Station equipment reliability management system innovation

    International Nuclear Information System (INIS)

    Gao Ligang; Wang Zongjun

    2006-01-01

    Daya Bay Nuclear Power Station has achieved good performance since its commercial operation in 1994. The equipment reliability management system that features Daya Bay characteristics has been established through constant technology introduction, digestion and innovation. It is also based on the success of operational system, equipment maintenance system and technical support system. The system lays a solid foundation for the long-term safe operation of power station. This article emphasizes on the innovation part of equipment reliability management system in Daya Bay. (authors)

  11. 77 FR 52317 - Record of Decision for Surveillance Towed Array Sensor System Low Frequency Active Sonar

    Science.gov (United States)

    2012-08-29

    ... DEPARTMENT OF DEFENSE Department of the Navy Record of Decision for Surveillance Towed Array Sensor System Low Frequency Active Sonar AGENCY: Department of the Navy, DoD. ACTION: Notice of decision... to employ up to four Surveillance Towed Array Sensor System Low Frequency Active (SURTASS LFA) sonar...

  12. Utilization of artificial intelligence techniques for the Space Station power system

    Science.gov (United States)

    Evatt, Thomas C.; Gholdston, Edward W.

    1988-01-01

    Due to the complexity of the Space Station Electrical Power System (EPS) as currently envisioned, artificial intelligence/expert system techniques are being investigated to automate operations, maintenance, and diagnostic functions. A study was conducted to investigate this technology as it applies to failure detection, isolation, and reconfiguration (FDIR) and health monitoring of power system components and of the total system. Control system utilization of expert systems for load scheduling and shedding operations was also researched. A discussion of the utilization of artificial intelligence/expert systems for Initial Operating Capability (IOC) for the Space Station effort is presented along with future plans at Rocketdyne for the utilization of this technology for enhanced Space Station power capability.

  13. Containment and surveillance devices

    International Nuclear Information System (INIS)

    Campbell, J.W.; Johnson, C.S.; Stieff, L.R.

    The growing acceptance of containment and surveillance as a means to increase safeguards effectiveness has provided impetus to the development of improved surveillance and containment devices. Five recently developed devices are described. The devices include one photographic and two television surveillance systems and two high security seals that can be verified while installed

  14. A Web-Based, Hospital-Wide Health Care-Associated Bloodstream Infection Surveillance and Classification System: Development and Evaluation.

    Science.gov (United States)

    Tseng, Yi-Ju; Wu, Jung-Hsuan; Lin, Hui-Chi; Chen, Ming-Yuan; Ping, Xiao-Ou; Sun, Chun-Chuan; Shang, Rung-Ji; Sheng, Wang-Huei; Chen, Yee-Chun; Lai, Feipei; Chang, Shan-Chwen

    2015-09-21

    Surveillance of health care-associated infections is an essential component of infection prevention programs, but conventional systems are labor intensive and performance dependent. To develop an automatic surveillance and classification system for health care-associated bloodstream infection (HABSI), and to evaluate its performance by comparing it with a conventional infection control personnel (ICP)-based surveillance system. We developed a Web-based system that was integrated into the medical information system of a 2200-bed teaching hospital in Taiwan. The system automatically detects and classifies HABSIs. In this study, the number of computer-detected HABSIs correlated closely with the number of HABSIs detected by ICP by department (n=20; r=.999 Psystem performed excellently with regard to sensitivity (98.16%), specificity (99.96%), positive predictive value (95.81%), and negative predictive value (99.98%). The system enabled decreasing the delay in confirmation of HABSI cases, on average, by 29 days. This system provides reliable and objective HABSI data for quality indicators, improving the delay caused by a conventional surveillance system.

  15. Sunglass detection method for automation of video surveillance system

    Science.gov (United States)

    Sikandar, Tasriva; Samsudin, Wan Nur Azhani W.; Hawari Ghazali, Kamarul; Mohd, Izzeldin I.; Fazle Rabbi, Mohammad

    2018-04-01

    Wearing sunglass to hide face from surveillance camera is a common activity in criminal incidences. Therefore, sunglass detection from surveillance video has become a demanding issue in automation of security systems. In this paper we propose an image processing method to detect sunglass from surveillance images. Specifically, a unique feature using facial height and width has been employed to identify the covered region of the face. The presence of covered area by sunglass is evaluated using facial height-width ratio. Threshold value of covered area percentage is used to classify the glass wearing face. Two different types of glasses have been considered i.e. eye glass and sunglass. The results of this study demonstrate that the proposed method is able to detect sunglasses in two different illumination conditions such as, room illumination as well as in the presence of sunlight. In addition, due to the multi-level checking in facial region, this method has 100% accuracy of detecting sunglass. However, in an exceptional case where fabric surrounding the face has similar color as skin, the correct detection rate was found 93.33% for eye glass.

  16. VigilAgent for the development of agent-based multi-robot surveillance systems

    OpenAIRE

    Gascueña Noheda, José Manuel; Navarro Martínez, Elena María; Fernández Caballero, Antonio

    2011-01-01

    Usually, surveillance applications are developed following an ad-hoc approach instead of using a methodology to guide stakeholders in achieving quality standards expected from commercial software. To solve this gap, our conjecture is that surveillance applications can be fully developed from their initial design stages by means of agent-based methodologies. Specifically, this paper describes the experience and the results of using a multi-agent systems approach according to the process provid...

  17. Evaluation of the novel respiratory virus surveillance program: Pediatric Early Warning Sentinel Surveillance (PEWSS).

    Science.gov (United States)

    Armour, Patricia A; Nguyen, Linh M; Lutman, Michelle L; Middaugh, John P

    2013-01-01

    Infections caused by respiratory viruses are associated with recurrent epidemics and widespread morbidity and mortality. Routine surveillance of these pathogens is necessary to determine virus activity, monitor for changes in circulating strains, and plan for public health preparedness. The Southern Nevada Health District in Las Vegas, Nevada, recruited five pediatric medical practices to serve as sentinel sites for the Pediatric Early Warning Sentinel Surveillance (PEWSS) program. Sentinel staff collected specimens throughout the year from ill children who met the influenza-like illness case definition and submitted specimens to the Southern Nevada Public Health Laboratory for molecular testing for influenza and six non-influenza viruses. Laboratory results were analyzed and reported to the medical and general communities in weekly bulletins year-round. PEWSS data were also used to establish viral respiratory seasonal baselines and in influenza vaccination campaigns. The surveillance program was evaluated using the Centers for Disease Control and Prevention's (CDC's) Updated Guidelines for Evaluating Public Health Surveillance Systems. PEWSS met three of six program usefulness criteria and seven of nine surveillance system attributes, which exceeded the CDC Guidelines evaluation criteria for a useful and complete public health surveillance program. We found that PEWSS is a useful and complete public health surveillance system that is simple, flexible, accessible, and stable.

  18. The Household Registration System

    Directory of Open Access Journals (Sweden)

    2000-06-01

    Full Text Available Although longitudinal experimental community health research is crucial to testing hypotheses about the demographic impact of health technologies, longitudinal demographic research field stations are rare, owing to the complexity and high cost of developing requisite computer software systems. This paper describes the Household Registration System (HRS, a software package that has been used for the rapid development of eleven surveillance systems in sub-Saharan Africa and Asia. Features of the HRS automate software generation for a family of surveillance applications, obviating the need for new and complex computer software systems for each new longitudinal demographic study.

  19. Survey of surveillance systems and select prevention activities for hepatitis B and C, European Union/European Economic Area, 2009.

    Science.gov (United States)

    Duffell, E F; van de Laar, M J

    2015-04-02

    Hepatitis B and C viral infections are leading causes of hepatic cirrhosis and cancer. The incidence and prevalence of both hepatitis B and C varies across European countries. European wide surveillance data help to understand the dynamic epidemiology of hepatitis B and C, which is important for the implementation and effectiveness of prevention and control activities.Comparison of surveillance data between countries in Europe is hampered by the differences in national healthcare and reporting systems. This report presents the results of a survey in 2009 which was undertaken to collect baseline information on surveillance systems and core prevention programmes for hepatitis B and C in individual European Union/ European Economic Area countries. The results provide key information to aid the interpretation of surveillance data, and while indicating heterogeneity in national surveillance systems and programmes, they highlight the potential of these systems. This resource has supported the implementation of a standardised European enhanced surveillance programme.

  20. Comparing national infectious disease surveillance systems : China and the Netherlands

    NARCIS (Netherlands)

    Vlieg, Willemijn L; Fanoy, Ewout B; van Asten, Liselotte; Liu, Xiaobo; Yang, Jun; Pilot, Eva; Bijkerk, Paul; van der Hoek, Wim; Krafft, Thomas; van der Sande, Marianne A; Liu, Qi-Yong

    2017-01-01

    BACKGROUND: Risk assessment and early warning (RAEW) are essential components of any infectious disease surveillance system. In light of the International Health Regulations (IHR)(2005), this study compares the organisation of RAEW in China and the Netherlands. The respective approaches towards

  1. Strengthening health security at the Hajj mass gatherings: characteristics of the infectious diseases surveillance systems operational during the 2015 Hajj.

    Science.gov (United States)

    Alotaibi, Badriah M; Yezli, Saber; Bin Saeed, Abdul-Aziz A; Turkestani, Abdulhafeez; Alawam, Amnah H; Bieh, Kingsley L

    2017-05-01

    Hajj is one of the largest and the most ethnically and culturally diverse mass gatherings worldwide. The use of appropriate surveillance systems ensures timely information management for effective planning and response to infectious diseases threats during the pilgrimage. The literature describes infectious diseases prevention and control strategies for Hajj but with limited information on the operations and characteristics of the existing Hajj infectious diseases surveillance systems. We reviewed documents, including guidelines and reports from the Saudi Ministry of Health's database, to describe the characteristics of the infectious diseases surveillance systems that were operational during the 2015 Hajj, highlighting best practices and gaps and proposing strategies for strengthening and improvement. Using Pubmed and Embase online search engines and a combination of search terms including, 'mass gatherings' 'Olympics' 'surveillance' 'Hajj' 'health security', we explored the existing literature and highlighted some lessons learnt from other international mass gatherings. A regular indicator-based infectious disease surveillance system generates routine reports from health facilities within the Kingdom to the regional and central public health directorates all year round. During Hajj, enhanced indicator-based notifiable diseases surveillance systems complement the existing surveillance tool to ensure timely reporting of event information for appropriate action by public health officials. There is need to integrate the existing Hajj surveillance data management systems and to implement syndromic surveillance as an early warning system for infectious disease control during Hajj. International engagement is important to strengthen Hajj infectious diseases surveillance and to prevent disease transmission and globalization of infectious agents which could undermine global health security. © International Society of Travel Medicine, 2017. Published by Oxford University

  2. Simple simulation training system for short-wave radio station

    Science.gov (United States)

    Tan, Xianglin; Shao, Zhichao; Tu, Jianhua; Qu, Fuqi

    2018-04-01

    The short-wave radio station is a most important transmission equipment of our signal corps, but in the actual teaching process, which exist the phenomenon of fewer equipment and more students, making the students' short-wave radio operation and practice time is very limited. In order to solve the above problems, to carry out shortwave radio simple simulation training system development is very necessary. This project is developed by combining hardware and software to simulate the voice communication operation and signal principle of shortwave radio station, and can test the signal flow of shortwave radio station. The test results indicate that this system is simple operation, human-machine interface friendly and can improve teaching more efficiency.

  3. A Data Management System for International Space Station Simulation Tools

    Science.gov (United States)

    Betts, Bradley J.; DelMundo, Rommel; Elcott, Sharif; McIntosh, Dawn; Niehaus, Brian; Papasin, Richard; Mah, Robert W.; Clancy, Daniel (Technical Monitor)

    2002-01-01

    Groups associated with the design, operational, and training aspects of the International Space Station make extensive use of modeling and simulation tools. Users of these tools often need to access and manipulate large quantities of data associated with the station, ranging from design documents to wiring diagrams. Retrieving and manipulating this data directly within the simulation and modeling environment can provide substantial benefit to users. An approach for providing these kinds of data management services, including a database schema and class structure, is presented. Implementation details are also provided as a data management system is integrated into the Intelligent Virtual Station, a modeling and simulation tool developed by the NASA Ames Smart Systems Research Laboratory. One use of the Intelligent Virtual Station is generating station-related training procedures in a virtual environment, The data management component allows users to quickly and easily retrieve information related to objects on the station, enhancing their ability to generate accurate procedures. Users can associate new information with objects and have that information stored in a database.

  4. AN AUTOMATED RAILWAY STATION TRAFFIC CONTROL SYSTEM

    African Journals Online (AJOL)

    AN AUTOMATED RAILWAY STATION TRAFFIC CONTROL SYSTEM. ... involve collision with automobiles or other vehicles and collision with other trains. ... the processed signals to control electromagnetic devices through motor drivers.

  5. Mapping HIV/STI behavioural surveillance in Europe

    Directory of Open Access Journals (Sweden)

    Lert France

    2010-10-01

    Full Text Available Abstract Background Used in conjunction with biological surveillance, behavioural surveillance provides data allowing for a more precise definition of HIV/STI prevention strategies. In 2008, mapping of behavioural surveillance in EU/EFTA countries was performed on behalf of the European Centre for Disease prevention and Control. Method Nine questionnaires were sent to all 31 member States and EEE/EFTA countries requesting data on the overall behavioural and second generation surveillance system and on surveillance in the general population, youth, men having sex with men (MSM, injecting drug users (IDU, sex workers (SW, migrants, people living with HIV/AIDS (PLWHA, and sexually transmitted infection (STI clinics patients. Requested data included information on system organisation (e.g. sustainability, funding, institutionalisation, topics covered in surveys and main indicators. Results Twenty-eight of the 31 countries contacted supplied data. Sixteen countries reported an established behavioural surveillance system, and 13 a second generation surveillance system (combination of biological surveillance of HIV/AIDS and STI with behavioural surveillance. There were wide differences as regards the year of survey initiation, number of populations surveyed, data collection methods used, organisation of surveillance and coordination with biological surveillance. The populations most regularly surveyed are the general population, youth, MSM and IDU. SW, patients of STI clinics and PLWHA are surveyed less regularly and in only a small number of countries, and few countries have undertaken behavioural surveys among migrant or ethnic minorities populations. In many cases, the identification of populations with risk behaviour and the selection of populations to be included in a BS system have not been formally conducted, or are incomplete. Topics most frequently covered are similar across countries, although many different indicators are used. In most

  6. Surveillance of nuclear power reactors

    International Nuclear Information System (INIS)

    Marini, J.

    1983-01-01

    Surveillance of nuclear power reactors is now a necessity imposed by such regulatory documents as USNRC Regulatory Guide 1.133. In addition to regulatory requirements, however, nuclear reactor surveillance offers plant operators significant economic advantages insofar as a single day's outage is very costly. The economic worth of a reactor surveillance system can be stated in terms of the improved plant availability provided through its capability to detect incidents before they occur and cause serious damage. Furthermore, the TMI accident has demonstrated the need for monitoring certain components to provide operators with clear information on their functional status. In response to the above considerations, Framatome has developed a line of products which includes: pressure vessel leakage detection systems, loose part detection systems, component vibration monitoring systems, and, crack detection and monitoring systems. Some of the surveillance systems developed by Framatome are described in this paper

  7. The EUVAC-NET survey: national pertussis surveillance systems in the European Union, Switzerland, Norway, and Iceland.

    Science.gov (United States)

    Schmidt, J E; Tozzi, A E; Rava, L; Glismann, S

    2001-06-01

    A questionnaire was mailed out to member states of the European Union (EU) plus Switzerland, Norway, and Iceland, to inquire about the type of information routinely recorded in national pertussis surveillance systems. Information was requested on surveillance methods, type of information recorded for cases of pertussis, vaccination schedule, type of vaccine used, and methods for estimating vaccination coverage. Local surveillance methods, vaccination strategies, and methods to estimate vaccination coverage were found to differ widely across the participating countries. The results of the questionnaire survey show, however, that there are comparable subsets of variables common to many countries. Future activities of the EUVAC-NET project will include defining the homogeneous elements in national systems and to group appropriately those countries with common surveillance features.

  8. An optimal beam alignment method for large-scale distributed space surveillance radar system

    Science.gov (United States)

    Huang, Jian; Wang, Dongya; Xia, Shuangzhi

    2018-06-01

    Large-scale distributed space surveillance radar is a very important ground-based equipment to maintain a complete catalogue for Low Earth Orbit (LEO) space debris. However, due to the thousands of kilometers distance between each sites of the distributed radar system, how to optimally implement the Transmitting/Receiving (T/R) beams alignment in a great space using the narrow beam, which proposed a special and considerable technical challenge in the space surveillance area. According to the common coordinate transformation model and the radar beam space model, we presented a two dimensional projection algorithm for T/R beam using the direction angles, which could visually describe and assess the beam alignment performance. Subsequently, the optimal mathematical models for the orientation angle of the antenna array, the site location and the T/R beam coverage are constructed, and also the beam alignment parameters are precisely solved. At last, we conducted the optimal beam alignment experiments base on the site parameters of Air Force Space Surveillance System (AFSSS). The simulation results demonstrate the correctness and effectiveness of our novel method, which can significantly stimulate the construction for the LEO space debris surveillance equipment.

  9. National Weather Service (NWS) Station Information System (SIS), Version 2

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — National Weather Service (NWS) Station Information System (SIS) contains observing station metadata from November 2016 to present. These are renditions are used for...

  10. Behavioral Risk Factor Surveillance System (BRFSS) Prevalence Data (2011 to present)

    Data.gov (United States)

    U.S. Department of Health & Human Services — 2011 to present. BRFSS combined land line and cell phone prevalence data. BRFSS is a continuous, state-based surveillance system that collects information about...

  11. Behavioral Risk Factor Surveillance System (BRFSS) Prevalence Data (2010 and prior)

    Data.gov (United States)

    U.S. Department of Health & Human Services — 1995-2010. BRFSS land line only prevalence data. BRFSS is a continuous, state-based surveillance system that collects information about modifiable risk factors for...

  12. Current French system of post-marketing drug surveillance.

    Science.gov (United States)

    Albengres, E; Gauthier, F; Tillement, J P

    1990-07-01

    The French system of drug surveillance is characterized by several original features: thirty regional centres are selected to cover all of France to collect, analyze and enter the adverse drug events in the national data bank. The system is based on a bank of well documented files submitted to a decision of imputation; the report of severe events by prescribers is mandatory; cases are collected either by spontaneous reporting (routine) or by direct request (intensive validation study); the system is being involved in studies of epidemiological type as carried out by the national system of health or a few societies of medicine as well as by the centres themselves in cooperative works on defined populations.

  13. Environmental surveillance: An integral part of the spill contingency plan

    International Nuclear Information System (INIS)

    Salinas, J.; Bozzo, W.

    1993-01-01

    Typically, the initial response to spills is directed at containing, controlling, and stopping the flow of spilled materials. The primary goal of such a response is to limit the spread and further impact of spilled material, and to initiate timely cleanup and recovery of affected areas. Surveillance of actual spill impacts has often followed an after the fact approach, using only immediately available resources. Surveillance may occur quickly after a spill, but in most incidents its occurs as a follow-up action after initial response and containment have been achieved. Insufficient planning may produce spill surveillance that inadequately assesses impacts, fails to incorporate baseline data, and does not clearly identify a cleanup recovery and endpoint. The management and operations contractor for the US Dept. of Energy's Strategic Petroleum Reserve (SPR) conducts environmental surveillance activities in response to spill incidents when they occur at these facilities. These surveillance activities, when conducted as part of the response, are useful instruments in the initial assessment of spill incidents, management of spill response, containment, and cleanup activities, and for monitoring and documenting postspill impacts and recovery. An Environmental Surveillance Plan (ESP) incorporated in the SPR Spill Contingency Plan provides for initiation of environmental surveillance as part of the spill response. The ESP outlines, through alogic tree, conditions for activating the plan, key indicator parameters for evaluation, detailed methods for establishing surveillance stations, lists of key personnel, locations of equipment necessary to perform surveillance, and conditions for termination of environmental surveillance

  14. Research on comprehensive decision-making of PV power station connecting system

    Science.gov (United States)

    Zhou, Erxiong; Xin, Chaoshan; Ma, Botao; Cheng, Kai

    2018-04-01

    In allusion to the incomplete indexes system and not making decision on the subjectivity and objectivity of PV power station connecting system, based on the combination of improved Analytic Hierarchy Process (AHP), Criteria Importance Through Intercriteria Correlation (CRITIC) as well as grey correlation degree analysis (GCDA) is comprehensively proposed to select the appropriate system connecting scheme of PV power station. Firstly, indexes of PV power station connecting system are divided the recursion order hierarchy and calculated subjective weight by the improved AHP. Then, CRITIC is adopted to determine the objective weight of each index through the comparison intensity and conflict between indexes. The last the improved GCDA is applied to screen the optimal scheme, so as to, from the subjective and objective angle, select the connecting system. Comprehensive decision of Xinjiang PV power station is conducted and reasonable analysis results are attained. The research results might provide scientific basis for investment decision.

  15. Dual keel Space Station payload pointing system design and analysis feasibility study

    Science.gov (United States)

    Smagala, Tom; Class, Brian F.; Bauer, Frank H.; Lebair, Deborah A.

    1988-01-01

    A Space Station attached Payload Pointing System (PPS) has been designed and analyzed. The PPS is responsible for maintaining fixed payload pointing in the presence of disturbance applied to the Space Station. The payload considered in this analysis is the Solar Optical Telescope. System performance is evaluated via digital time simulations by applying various disturbance forces to the Space Station. The PPS meets the Space Station articulated pointing requirement for all disturbances except Shuttle docking and some centrifuge cases.

  16. Rotating machinery surveillance system reduces plant downtime and radiation exposure

    International Nuclear Information System (INIS)

    Bohanick, J.S.; Robinson, J.C.; Allen, J.W.

    1988-01-01

    A rotating machinery surveillance system (RMSS) was permanently installed at Grand Gulf nuclear station (GGNS) as part of a program sponsored by the US Department of Energy whose goal was to reduce radiation exposure to power plant personnel resulting from the inspection, maintenance, and repair of rotating machinery. The RMSS was installed at GGNS in 1983 to continuously monitor 173 analog vibration signals from proximity probes mounted on 26 machine trains and ∼450 process data points via a computer data link. Vibration frequency spectra, i.e., the vibration amplitude versus frequency of vibration, and various characterizations of these spectra are the fundamental data collected by the RMSS for performing machinery diagnostics. The RMSS collects vibration frequency spectra on a daily basis for all the monitored rotating equipment and automatically stores the collected spectra for review by the vibration engineer. Vibration spectra automatically stored by the RMSS fall into categories that include the last normal, alarm, minimum and maximum, past three-day data set, baseline, current, and user-saved spectra. During first and second fuel-cycle operation at GGNS, several significant vibration problems were detected by the RMSS. Two of these are presented in this paper: recirculation pumps and turbine-generator bearing degradation. The total reduction in personnel radiation exposure at GGNS from 1985 to 1987 due to the presence of the RMSS was estimated to be in the range from 49 to 54 person-rem

  17. Falling-incident detection and throughput enhancement in a multi-camera video-surveillance system.

    Science.gov (United States)

    Shieh, Wann-Yun; Huang, Ju-Chin

    2012-09-01

    For most elderly, unpredictable falling incidents may occur at the corner of stairs or a long corridor due to body frailty. If we delay to rescue a falling elder who is likely fainting, more serious consequent injury may occur. Traditional secure or video surveillance systems need caregivers to monitor a centralized screen continuously, or need an elder to wear sensors to detect falling incidents, which explicitly waste much human power or cause inconvenience for elders. In this paper, we propose an automatic falling-detection algorithm and implement this algorithm in a multi-camera video surveillance system. The algorithm uses each camera to fetch the images from the regions required to be monitored. It then uses a falling-pattern recognition algorithm to determine if a falling incident has occurred. If yes, system will send short messages to someone needs to be noticed. The algorithm has been implemented in a DSP-based hardware acceleration board for functionality proof. Simulation results show that the accuracy of falling detection can achieve at least 90% and the throughput of a four-camera surveillance system can be improved by about 2.1 times. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. Challenges in the implementation of an electronic surveillance system in a resource-limited setting: Alerta, in Peru

    Directory of Open Access Journals (Sweden)

    Soto Giselle

    2008-11-01

    Full Text Available Abstract Background Infectious disease surveillance is a primary public health function in resource-limited settings. In 2003, an electronic disease surveillance system (Alerta was established in the Peruvian Navy with support from the U.S. Naval Medical Research Center Detachment (NMRCD. Many challenges arose during the implementation process, and a variety of solutions were applied. The purpose of this paper is to identify and discuss these issues. Methods This is a retrospective description of the Alerta implementation. After a thoughtful evaluation according to the Centers for Disease Control and Prevention (CDC guidelines, the main challenges to implementation were identified and solutions were devised in the context of a resource-limited setting, Peru. Results After four years of operation, we have identified a number of challenges in implementing and operating this electronic disease surveillance system. These can be divided into the following categories: (1 issues with personnel and stakeholders; (2 issues with resources in a developing setting; (3 issues with processes involved in the collection of data and operation of the system; and (4 issues with organization at the central hub. Some of the challenges are unique to resource-limited settings, but many are applicable for any surveillance system. For each of these challenges, we developed feasible solutions that are discussed. Conclusion There are many challenges to overcome when implementing an electronic disease surveillance system, not only related to technology issues. A comprehensive approach is required for success, including: technical support, personnel management, effective training, and cultural sensitivity in order to assure the effective deployment of an electronic disease surveillance system.

  19. Video Surveillance using a Multi-Camera Tracking and Fusion System

    OpenAIRE

    Zhang , Zhong; Scanlon , Andrew; Yin , Weihong; Yu , Li; Venetianer , Péter L.

    2008-01-01

    International audience; Usage of intelligent video surveillance (IVS) systems is spreading rapidly. These systems are being utilized in a wide range of applications. In most cases, even in multi-camera installations, the video is processed independently in each feed. This paper describes a system that fuses tracking information from multiple cameras, thus vastly expanding its capabilities. The fusion relies on all cameras being calibrated to a site map, while the individual sensors remain lar...

  20. Surveillance systems (PWR) - loose parts monitoring - vibration monitoring - leakage detection

    International Nuclear Information System (INIS)

    Schuette, A.; Blaesig, H.

    1982-01-01

    The contribution is engaged in the task and the results of the loose parts monitoring and the vibration monitoring following from the practice at the PWR of Biblis. First a description of both systems - location and type of the sensors used, the treatment of the measurements and the indications - is given. The results of the analysis of some events picked up by the surveillance systems are presented showing applicabilty and benefit of such systems. (orig.)

  1. Strengthening systems for communicable disease surveillance: creating a laboratory network in Rwanda

    Directory of Open Access Journals (Sweden)

    Ndihokubwayo Jean B

    2011-06-01

    Full Text Available Abstract Background The recent emergence of a novel strain of influenza virus with pandemic potential underscores the need for quality surveillance and laboratory services to contribute to the timely detection and confirmation of public health threats. To provide a framework for strengthening disease surveillance and response capacities in African countries, the World Health Organization Regional Headquarters for Africa (AFRO developed Integrated Disease Surveillance and Response (IDSR aimed at improving national surveillance and laboratory systems. IDSR emphasizes the linkage of information provided by public health laboratories to the selection of relevant, appropriate and effective public health responses to disease outbreaks. Methods We reviewed the development of Rwanda's National Reference Laboratory (NRL to understand essential structures involved in creating a national public health laboratory network. We reviewed documents describing the NRL's organization and record of test results, conducted site visits, and interviewed health staff in the Ministry of Health and in partner agencies. Findings were developed by organizing thematic categories and grouping examples within them. We purposefully sought to identify success factors as well as challenges inherent in developing a national public health laboratory system. Results Among the identified success factors were: a structured governing framework for public health surveillance; political commitment to promote leadership for stronger laboratory capacities in Rwanda; defined roles and responsibilities for each level; coordinated approaches between technical and funding partners; collaboration with external laboratories; and use of performance results in advocacy with national stakeholders. Major challenges involved general infrastructure, human resources, and budgetary constraints. Conclusions Rwanda's experience with collaborative partnerships contributed to creation of a functional

  2. Traffic Flow Wide-Area Surveillance system

    Energy Technology Data Exchange (ETDEWEB)

    Allgood, G.O.; Ferrell, R.K.; Kercel, S.W.; Abston, R.A.

    1994-09-01

    Traffic management can be thought of as a stochastic queuing process where the serving time at one of its control points is dynamically linked to the global traffic pattern, which is, in turn, dynamically linked to the control point. For this closed-loop system to be effective, the traffic management system must sense and interpret a large spatial projection of data originating from multiple sensor suites. This concept is the basis for the development of a Traffic Flow Wide-Area Surveillance (TFWAS) system. This paper presents the results of a study by Oak Ridge National Laboratory to define the operational specifications and characteristics, to determine the constraints, and to examine the state of technology of a TFWAS system in terms of traffic management and control. In doing so, the functions and attributes of a TFWAS system are mapped into an operational structure consistent with the Intelligent Vehicle Highway System (IVHS) concept and the existing highway infrastructure. This mapping includes identifying candidate sensor suites and establishing criteria, requirements, and performance measures by which these systems can be graded in their ability and practicality to meet the operational requirements of a TFWAS system. In light of this, issues such as system integration, applicable technologies, impact on traffic management and control, and public acceptance are addressed.

  3. Traffic flow wide-area surveillance system

    Science.gov (United States)

    Allgood, Glenn O.; Ferrell, Regina K.; Kercel, Stephen W.; Abston, Ruth A.

    1995-01-01

    Traffic management can be thought of as a stochastic queuing process where the serving time at one of its control points is dynamically linked to the global traffic pattern, which is, in turn, dynamically linked to the control point. For this closed-loop system to be effective, the traffic management system must sense and interpret a large spatial projection of data originating from multiple sensor suites. This concept is the basis for the development of a traffic flow wide-area surveillance (TFWAS) system. This paper presents the results of a study by Oak Ridge National Laboratory to define the operational specifications and characteristics, to determine the constraints, and to examine the state of technology of a TFWAS system in terms of traffic management and control. In doing so, the functions and attributes of a TFWAS system are mapped into an operational structure consistent with the Intelligent Vehicle Highway System (IVHS) concept and the existing highway infrastructure. This mapping includes identifying candidate sensor suites and establishing criteria, requirements, and performance measures by which these systems can be graded in their ability and practicality to meet the operational requirements of a TFWAS system. In light of this, issues such as system integration, applicable technologies, impact on traffic management and control, and public acceptance are addressed.

  4. R and D study on on-line criticality surveillance system (III)

    International Nuclear Information System (INIS)

    Yamada, Sumasu

    1999-02-01

    The Criticality Surveillance System should have high reliability and high expandability enable to apply new approaches. Under this basic concept, a basic design of the Criticality Surveillance System has been proposed in 1997. We propose here several new ideas of modification to the original design of the Criticality Surveillance System, and also reports some results of numerical analysis over the DCA experiments in 1996. In this report, first, we proposed the modification of the Criticality Surveillance System by adding a series of modules for the usage of the Feynman-α method over the γ-ray signal, because recent studies revealed that the statistical analysis of the γ-ray signal in time domain can provide very good information of the reactor decay constant even in the case of low count rate. This modification could increase the reliability of the Criticality Surveillance System over the wide range of amount of the reprocessed fuel in the tank. Last year we have developed an executable ADF program based on the Least Mean Squares, as the redundancy to the recursive ARMA model identification algorithm. However, this algorithm has a property that the convergence rate of parameter estimation becomes very slow when input data is corrupted with colored noise. To cope with this problem, we introduced a new ADF algorithm called Block ADF algorithm, which is developed to improve the convergence rate with less computational load to the computer. In Chapter 2, we showed the basic theory and a fast adaptive filter algorithm using eigenvalue reciprocals as stepsizes in Chapter 3. This new algorithm provides a stable parameter estimates with less computation as fast as the Recursive Least Squares Method. Thirdly, we introduced a notch filter for power line noise and a software. This filter has to be developed for each specific sampling frequency and specific power line frequency, however, this filter can remove not only the line spectrum of the power line frequency but also

  5. The Establishment and Function of Schistosomiasis Surveillance System Towards Elimination in The People's Republic of China.

    Science.gov (United States)

    Zhang, L-J; Li, S-Z; Wen, L-Y; Lin, D-D; Abe, E M; Zhu, R; Du, Y; Lv, S; Xu, J; Webster, B L; Rollinson, D; Zhou, X-N

    2016-01-01

    Schistosoma japonicum is the main schistosome species in The People's Republic of China, causing intestinal schistosomiasis, a debilitating disease of public health importance. The People's Republic of China used to be heavily endemic with schistosomiasis, but great progress has been made through the vigorous efforts of the national control programmes in the last six decades. Presently, efforts are geared towards eliminating schistosomiasis from The People's Republic of China by the end of 2025 through effective schistosomiasis surveillance, an important component in the drive towards schistosomiasis elimination. Therefore, this article explicitly outlines the development and progress made in schistosomiasis surveillance since 1990 with a special focus on the new surveillance system in use. Although the surveillance system has steadily improved over the years, it is faced with many challenges. Hence, more efforts are needed to establish an effective and sensitive evaluation system for the national schistosomiasis elimination programme in The People's Republic of China. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Congenital rubella syndrome surveillance as a platform for surveillance of other congenital infections, Peru, 2004-2007.

    Science.gov (United States)

    Whittembury, Alvaro; Galdos, Jorge; Lugo, María; Suárez-Ognio, Luis; Ortiz, Ana; Cabezudo, Edwin; Martínez, Mario; Castillo-Solórzano, Carlos; Andrus, Jon Kim

    2011-09-01

    Rubella during pregnancy can cause serious fetal abnormalities and death. Peru has had integrated measles/rubella surveillance since 2000 but did not implement congenital rubella syndrome (CRS) surveillance until 2004, in accordance with the Pan American Health Organization recommendations for rubella elimination. The article describes the experience from the CRS sentinel surveillance system in Peru. Peru has maintained a national sentinel surveillance system for reporting confirmed and suspected CRS cases since 2004. A surveillance protocol was implemented with standardized case definitions and instruments in the selected sentinel sites. Each sentinel site completes their case investigations and report forms and sends the reports to the Health Region Epidemiology Department, which forwards the data to the national Epidemiology Department. CRS surveillance data were analyzed for the period 2004-2007. During the period 2004-2007, 16 health facilities, which are located in 9 of the 33 health regions, representing the 3 main geographical areas (coast, mountain, and jungle), were included as sentinel sites for the CRS surveillance. A total of 2061 suspected CRS cases were reported to the system. Of these, 11 were classified as CRS and 23 as congenital rubella infection. Factors significantly associated with rubella vertical transmission were: (1) in the mother, maternal history of rash during pregnancy (odds ratio [OR], 12.0; 95% confidence interval [CI], 3.8-37.8); (2) and in the infant, pigmentary retinopathy (OR, 18.4; 95% CI, 3.2-104.6), purpura (OR, 14.7; 95% CI, 2.8-78.3), and developmental delay (OR, 4.4; 95% CI, 1.75-11.1). The surveillance system has been able to identify rubella vertical transmission, reinforcing the evidence that rubella was a public health problem in Peru. This system may serve as a platform to implement surveillance for other congenital infections in Peru.

  7. Developing a database management system to support birth defects surveillance in Florida.

    Science.gov (United States)

    Salemi, Jason L; Hauser, Kimberlea W; Tanner, Jean Paul; Sampat, Diana; Correia, Jane A; Watkins, Sharon M; Kirby, Russell S

    2010-01-01

    The value of any public health surveillance program is derived from the ways in which data are managed and used to improve the public's health. Although birth defects surveillance programs vary in their case volume, budgets, staff, and objectives, the capacity to operate efficiently and maximize resources remains critical to long-term survival. The development of a fully-integrated relational database management system (DBMS) can enrich a surveillance program's data and improve efficiency. To build upon the Florida Birth Defects Registry--a statewide registry relying solely on linkage of administrative datasets and unconfirmed diagnosis codes-the Florida Department of Health provided funding to the University of South Florida to develop and pilot an enhanced surveillance system in targeted areas with a more comprehensive approach to case identification and diagnosis confirmation. To manage operational and administrative complexities, a DBMS was developed, capable of managing transmission of project data from multiple sources, tracking abstractor time during record reviews, offering tools for defect coding and case classification, and providing reports to DBMS users. Since its inception, the DBMS has been used as part of our surveillance projects to guide the receipt of over 200 case lists and review of 12,924 fetuses and infants (with associated maternal records) suspected of having selected birth defects in over 90 birthing and transfer facilities in Florida. The DBMS has provided both anticipated and unexpected benefits. Automation of the processes for managing incoming case lists has reduced clerical workload considerably, while improving accuracy of working lists for field abstraction. Data quality has improved through more effective use of internal edits and comparisons with values for other data elements, while simultaneously increasing abstractor efficiency in completion of case abstraction. We anticipate continual enhancement to the DBMS in the future

  8. The Copyright Surveillance Industry

    Directory of Open Access Journals (Sweden)

    Mike Zajko

    2015-09-01

    Full Text Available Creative works are now increasingly distributed as digital “content” through the internet, and copyright law has created powerful incentives to monitor and control these flows. This paper analyzes the surveillance industry that has emerged as a result. Copyright surveillance systems identify copyright infringement online and identify persons to hold responsible for infringing acts. These practices have raised fundamental questions about the nature of identification and attribution on the internet, as well as the increasing use of algorithms to make legal distinctions. New technologies have threatened the profits of some media industries through copyright infringement, but also enabled profitable forms of mass copyright surveillance and enforcement. Rather than a system of perfect control, copyright enforcement continues to be selective and uneven, but its broad reach results in systemic harm and provides opportunities for exploitation. It is only by scrutinizing copyright surveillance practices and copyright enforcement measures that we can evaluate these consequences.

  9. GeoMedStat: an integrated spatial surveillance system to track air pollution and associated healthcare events

    Directory of Open Access Journals (Sweden)

    Fazlay S. Faruque

    2014-12-01

    Full Text Available Air pollutants, such as particulate matter with a diameter ≤2.5 microns (PM2.5 and ozone (O3, are known to exacerbate asthma and other respiratory diseases. An integrated surveillance system that tracks such air pollutants and associated disease incidence can assist in risk assessment, healthcare preparedness and public awareness. However, the implementation of such an integrated environmental health surveillance system is a challenge due to the disparate sources of many types of data and the implementation becomes even more complicated for a spatial and real-time system due to lack of standardised technological components and data incompatibility. In addition, accessing and utilising health data that are considered as Protected Health Information (PHI require maintaining stringent protocols, which have to be supported by the system. This paper aims to illustrate the development of a spatial surveillance system (GeoMedStat that is capable of tracking daily environmental pollutants along with both daily and historical patient encounter data. It utilises satellite data and the groundmonitor data from the US National Aeronautics and Space Administration (NASA and the US Environemental Protection Agenecy (EPA, rspectively as inputs estimating air pollutants and is linked to hospital information systems for accessing chief complaints and disease classification codes. The components, developmental methods, functionality of GeoMedStat and its use as a real-time environmental health surveillance system for asthma and other respiratory syndromes in connection with with PM2.5 and ozone are described. It is expected that the framework presented will serve as an example to others developing real-time spatial surveillance systems for pollutants and hospital visits.

  10. Vector Borne Infections in Italy: Results of the Integrated Surveillance System for West Nile Disease in 2013

    Directory of Open Access Journals (Sweden)

    Christian Napoli

    2015-01-01

    Full Text Available The epidemiology of West Nile disease (WND is influenced by multiple ecological factors and, therefore, integrated surveillance systems are needed for early detecting the infection and activating consequent control actions. As different animal species have different importance in the maintenance and in the spread of the infection, a multispecies surveillance approach is required. An integrated and comprehensive surveillance system is in place in Italy aiming at early detecting the virus introduction, monitoring the possible infection spread, and implementing preventive measures for human health. This paper describes the integrated surveillance system for WND in Italy, which incorporates data from veterinary and human side in order to evaluate the burden of infection in animals and humans and provide the public health authorities at regional and national levels with the information needed for a fine tune response.

  11. Optimization and Feasibility Analysis of Satellite Earth Station Power System Using Homer

    Directory of Open Access Journals (Sweden)

    Hassen T. Dorrah

    2012-06-01

    Full Text Available Satellite earth stations which located in remote areas are one of many applications powered by the renewable energy sources. Ground system consists of ground station and control centers working together to support the spacecraft and the data user. Earth station consists of major subsystems, transmitter, receiver, antenna, tracking equipment, terrestrial interface equipment and power supply. Power subsystem is an important part that required for supplying the earth station with electrical power to continue communicating with its remote sensing satellite. This paper deals with simulation and optimal sizing of earth station power system using HOMER software. A combination of two energy sources (solar, and wind to provide a continuous electric power production is used to determine the optimum system operation. Three system configurations are compared with respect to the total net present cost (NPC and levelized cost of energy (COE. Also, economical study will be analyzed for energy demand and sensitivity analysis will be performed.

  12. Perceptions and acceptability of some stakeholders about the bovine tuberculosis surveillance system for wildlife (Sylvatub) in France

    Science.gov (United States)

    2018-01-01

    Bovine tuberculosis (bTB) is a common disease of cattle and wildlife, with economic repercussions and implications for animal and human health. The surveillance of bTB in wildlife is particularly important, to shed light on the epidemiological role of wild species and for the adaptation of control measures. In France, a bTB surveillance system for free-ranging wildlife, the Sylvatub system, was launched in 2011 on wild boars, red deer, roe deer and badgers. It relies on active and passive surveillance activities, constrained by practical difficulties, such as the accessibility of wild animals, and regulatory rules for the trapping of badgers, for example. We report here the first assessment of stakeholders’ perceptions of the Sylvatub system and its acceptability, based on 20 individual semi-structured interviews with three types of stakeholder (collectors, coordinators, officers) in areas with different rates of bTB infection. With the caveat that these findings cannot be assumed to be representative of the national situation, we found that the Sylvatub system was considered useful by all the stakeholders interviewed. Those from the world of hunting participate in surveillance mostly to help livestock farmers, who are not systematically involved in bTB surveillance in wildlife. Many practical and regulatory constraints were raised, which could be offset by recognition of the work done by the “hunting community”, to maintain the willingness of these individuals to participate. We also identified a need for improvements in communication and information. Qualitative information, such as that collected here, is essential to improve our understanding of the reasons favoring and disfavoring participation in surveillance, and should be taken into account in the evaluation process. These results are relevant to hunters and to veterinary authorities wishing to identify the determinants of participation in the Sylvatub system. They could provide support for decision

  13. Pervasive surveillance-agent system based on wireless sensor networks: design and deployment

    International Nuclear Information System (INIS)

    Martínez, José F; Bravo, Sury; García, Ana B; Corredor, Iván; Familiar, Miguel S; López, Lourdes; Hernández, Vicente; Da Silva, Antonio

    2010-01-01

    Nowadays, proliferation of embedded systems is enhancing the possibilities of gathering information by using wireless sensor networks (WSNs). Flexibility and ease of installation make these kinds of pervasive networks suitable for security and surveillance environments. Moreover, the risk for humans to be exposed to these functions is minimized when using these networks. In this paper, a virtual perimeter surveillance agent, which has been designed to detect any person crossing an invisible barrier around a marked perimeter and send an alarm notification to the security staff, is presented. This agent works in a state of 'low power consumption' until there is a crossing on the perimeter. In our approach, the 'intelligence' of the agent has been distributed by using mobile nodes in order to discern the cause of the event of presence. This feature contributes to saving both processing resources and power consumption since the required code that detects presence is the only system installed. The research work described in this paper illustrates our experience in the development of a surveillance system using WNSs for a practical application as well as its evaluation in real-world deployments. This mechanism plays an important role in providing confidence in ensuring safety to our environment

  14. The installation and performance test of the surveillance system for DUPIC facility

    International Nuclear Information System (INIS)

    Kim, Dong Young; Kim, Ho Dong; Cha, Hong Ryul

    2000-07-01

    We have developed the real time surveillance system, named by DSSS, for DUPIC test facility. The system acquires data from He-3 neutron monitors(DSNM) and CCD cameras to automatically diagnose the transportation status of nuclear material. This technical report shortly illustrates important features of hardware and software of the system

  15. The installation and performance test of the surveillance system for DUPIC facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Young; Kim, Ho Dong; Cha, Hong Ryul

    2000-07-01

    We have developed the real time surveillance system, named by DSSS, for DUPIC test facility. The system acquires data from He-3 neutron monitors(DSNM) and CCD cameras to automatically diagnose the transportation status of nuclear material. This technical report shortly illustrates important features of hardware and software of the system.

  16. EpiScanGIS: an online geographic surveillance system for meningococcal disease

    Directory of Open Access Journals (Sweden)

    Albert Jürgen

    2008-07-01

    Full Text Available Abstract Background Surveillance of infectious diseases increasingly relies on Geographic Information Systems (GIS. The integration of pathogen fine typing data in dynamic systems and visualization of spatio-temporal clusters are a technical challenge for system development. Results An online geographic information system (EpiScanGIS based on open source components has been launched in Germany in May 2006 for real time provision of meningococcal typing data in conjunction with demographic information (age, incidence, population density. Spatio-temporal clusters of disease detected by computer assisted cluster analysis (SaTScan™ are visualized on maps. EpiScanGIS enables dynamic generation of animated maps. The system is based on open source components; its architecture is open for other infectious agents and geographic regions. EpiScanGIS is available at http://www.episcangis.org, and currently has 80 registered users, mostly from the public health service in Germany. At present more than 2,900 cases of invasive meningococcal disease are stored in the database (data as of June 3, 2008. Conclusion EpiScanGIS exemplifies GIS applications and early-warning systems in laboratory surveillance of infectious diseases.

  17. A Framework for People Re-Identification in Multi-Camera Surveillance Systems

    Science.gov (United States)

    Ammar, Sirine; Zaghden, Nizar; Neji, Mahmoud

    2017-01-01

    People re-identification has been a very active research topic recently in computer vision. It is an important application in surveillance system with disjoint cameras. This paper is focused on the implementation of a human re-identification system. First the face of detected people is divided into three parts and some soft-biometric traits are…

  18. Results of EMC market surveillance tests for UPS systems

    Energy Technology Data Exchange (ETDEWEB)

    Rajamaeki, J. [Safety Technology Authority, Helsinki (Finland)

    1997-12-31

    This paper reports the first wide electromagnetic compatibility (EMC) market surveillance project in Finland in which the uninterruptible power systems (UPS) on the Finnish market are monitored. Altogether 11 UPS units are EMC tested and the results of these tests are described in this paper. The effect of basic characters of UPS on the level of electromagnetic interference are analysed. (orig.) 3 refs.

  19. Reporting and Surveillance for Norovirus Outbreaks

    Science.gov (United States)

    ... Vaccine Surveillance Network (NVSN) Foodborne Diseases Active Surveillance Network (FoodNet) National Outbreak Reporting System (NORS) Estimates of Foodborne Illness in the United States CDC's Vessel Sanitation Program CDC Feature: Surveillance for Norovirus Outbreaks Top ...

  20. The process monitoring computer system an integrated operations and safeguards surveillance system

    International Nuclear Information System (INIS)

    Liester, N.A.

    1995-01-01

    The use of the Process Monitoring Computer System (PMCS) at the Idaho Chemical Processing Plant (ICPP) relating to Operations and Safeguards concerns is discussed. Measures taken to assure the reliability of the system data are outlined along with the measures taken to assure the continuous availability of that data for use within the ICPP. The integration of process and safeguards information for use by the differing organizations is discussed. The PMCS successfully demonstrates the idea of remote Safeguards surveillance and the need for sharing of common information between different support organizations in an operating plant

  1. Privacy as Invisibility: Pervasive Surveillance and the Privatization of Peer-to-Peer Systems

    Directory of Open Access Journals (Sweden)

    Francesca Musiani

    2011-06-01

    Full Text Available This article addresses the ongoing, increasing privatization of peer-to-peer (P2P file sharing systems – the emergence of systems that users may only join by personal, friend-to-friend invitation. It argues that, within P2P systems, privacy is increasingly coinciding with “mere” invisibility vis-à-vis the rest of the Internet ecosystem because of a trend that has shaped the recent history of P2P technology: The alternation between forms of pervasive surveillance of such systems, and reactions by developers and users to such restrictive measures. Yet, it also suggests that the richness of today’s landscape of P2P technology development and use, mainly in the field of Internet-based services, opens up new dimensions to the conceptualization of privacy, and may give room to a more articulate definition of the concept as related to P2P technology; one that includes not only the need of protection from external attacks, and the temporary outcomes of the competition between surveillance and counter-surveillance measures, but also issues such as user empowerment through better control over personal information, reconfiguration of data management practices, and removal of intermediaries in sharing and communication activities.

  2. Emulador de Master System 2 corriendo bajo PlayStation Portable

    OpenAIRE

    García Flores, Jorge

    2013-01-01

    Creación de un emulador de Master System 2 (videoconsola de SEGA) para ser ejecutado en PlayStation Portable (videoconsola de Sony), implentando los lenguajes de programación C y ensamblados. El uso de este emulador servirá para poder ejecutar los videojuegos para Master System 2 en la videoconsola PlayStation Portable. Ingeniería Técnica en Informática de Gestión

  3. Systematic review of electronic surveillance of infectious diseases with emphasis on antimicrobial resistance surveillance in resource-limited settings.

    Science.gov (United States)

    Rattanaumpawan, Pinyo; Boonyasiri, Adhiratha; Vong, Sirenda; Thamlikitkul, Visanu

    2018-02-01

    Electronic surveillance of infectious diseases involves rapidly collecting, collating, and analyzing vast amounts of data from interrelated multiple databases. Although many developed countries have invested in electronic surveillance for infectious diseases, the system still presents a challenge for resource-limited health care settings. We conducted a systematic review by performing a comprehensive literature search on MEDLINE (January 2000-December 2015) to identify studies relevant to electronic surveillance of infectious diseases. Study characteristics and results were extracted and systematically reviewed by 3 infectious disease physicians. A total of 110 studies were included. Most surveillance systems were developed and implemented in high-income countries; less than one-quarter were conducted in low-or middle-income countries. Information technologies can be used to facilitate the process of obtaining laboratory, clinical, and pharmacologic data for the surveillance of infectious diseases, including antimicrobial resistance (AMR) infections. These novel systems require greater resources; however, we found that using electronic surveillance systems could result in shorter times to detect targeted infectious diseases and improvement of data collection. This study highlights a lack of resources in areas where an effective, rapid surveillance system is most needed. The availability of information technology for the electronic surveillance of infectious diseases, including AMR infections, will facilitate the prevention and containment of such emerging infectious diseases. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  4. Microbiological Food Safety Surveillance in China

    Directory of Open Access Journals (Sweden)

    Xiaoyan Pei

    2015-08-01

    Full Text Available Microbiological food safety surveillance is a system that collects data regarding food contamination by foodborne pathogens, parasites, viruses, and other harmful microbiological factors. It helps to understand the spectrum of food safety, timely detect food safety hazards, and provide relevant data for food safety supervision, risk assessment, and standards-setting. The study discusses the microbiological surveillance of food safety in China, and introduces the policies and history of the national microbiological surveillance system. In addition, the function and duties of different organizations and institutions are provided in this work, as well as the generation and content of the surveillance plan, quality control, database, and achievement of the microbiological surveillance of food safety in China.

  5. An Expert System And Simulation Approach For Sensor Management & Control In A Distributed Surveillance Network

    Science.gov (United States)

    Leon, Barbara D.; Heller, Paul R.

    1987-05-01

    A surveillance network is a group of multiplatform sensors cooperating to improve network performance. Network control is distributed as a measure to decrease vulnerability to enemy threat. The network may contain diverse sensor types such as radar, ESM (Electronic Support Measures), IRST (Infrared search and track) and E-0 (Electro-Optical). Each platform may contain a single sensor or suite of sensors. In a surveillance network it is desirable to control sensors to make the overall system more effective. This problem has come to be known as sensor management and control (SM&C). Two major facets of network performance are surveillance and survivability. In a netted environment, surveillance can be enhanced if information from all sensors is combined and sensor operating conditions are controlled to provide a synergistic effect. In contrast, when survivability is the main concern for the network, the best operating status for all sensors would be passive or off. Of course, improving survivability tends to degrade surveillance. Hence, the objective of SM&C is to optimize surveillance and survivability of the network. Too voluminous data of various formats and the quick response time are two characteristics of this problem which make it an ideal application for Artificial Intelligence. A solution to the SM&C problem, presented as a computer simulation, will be presented in this paper. The simulation is a hybrid production written in LISP and FORTRAN. It combines the latest conventional computer programming methods with Artificial Intelligence techniques to produce a flexible state-of-the-art tool to evaluate network performance. The event-driven simulation contains environment models coupled with an expert system. These environment models include sensor (track-while-scan and agile beam) and target models, local tracking, and system tracking. These models are used to generate the environment for the sensor management and control expert system. The expert system

  6. Virginia power nuclear power station engineer training program

    International Nuclear Information System (INIS)

    Williams, T.M.; Haberstroh-Timpano, S.

    1987-01-01

    In response to the Institute of Nuclear Power Operations (INPO) accreditation requirements for technical staff and manager, Virginia Power developed the Nuclear Power Station Engineer Training Programs (NPSETP). The NPSETP is directed toward enhancing the specific knowledge and skills of company engineers, especially newly hired engineers. The specific goals of the program are to promote safe and reliable plant operation by providing engineers and appropriate engineering technicians with (1) station-specific basic skills; (2) station-specific specialized skills in the areas of surveillance and test, plant engineering, nuclear safety, and in-service inspection. The training is designed to develop, maintain, and document through demonstration the required knowledge and skills of the engineers in the identified groups at North Anna and Surry Power Stations. The program responds to American National Standards Institute, INPO, and US Nuclear Regulatory Commission standards

  7. Challenges of implementing an Integrated Disease Surveillance and ...

    African Journals Online (AJOL)

    Tanzania adopted an Integrated Disease Surveillance and Response (IDSR) strategy in 1998 in order to strengthen its infectious disease surveillance system. During that time, the country had 5 separate surveillance systems to monitor infectious disease trends and disease control programmes. The systems included the ...

  8. System of wireless base stations employing shadow prices for power load balancing

    NARCIS (Netherlands)

    2011-01-01

    In one aspect, a system is provided. In one embodiment, the system includes a plurality of wireless base stations that are located in a contiguous spatial coverage region of a cellular communication system. Each wireless base station that is configured to generate a coverage pilot beam to enable

  9. Critical Surveillance Studies in the Information Society

    Directory of Open Access Journals (Sweden)

    Thomas Allmer

    2011-11-01

    Full Text Available The overall aim of this paper is to clarify how we can theorize and systemize economic surveillance. Surveillance studies scholars like David Lyon stress that economic surveillance such as monitoring consumers or the workplace are central aspects of surveillance societies. The approach that is advanced in this work recognizes the importance of the role of the economy in contemporary surveillance societies. The paper at hand constructs theoretically founded typologies in order to systemize the existing literature of surveillance studies and to analyze examples of surveillance. Therefore, it mainly is a theoretical approach combined with illustrative examples. This contribution contains a systematic discussion of the state of the art of surveillance and clarifies how different notions treat economic aspects of surveillance. In this work it is argued that the existing literature is insufficient for studying economic surveillance. In contrast, a typology of surveillance in the modern economy, which is based on foundations of a political economy approach, allows providing a systematic analysis of economic surveillance on the basis of current developments on the Internet. Finally, some political recommendations are drawn in order to overcome economic surveillance. This contribution can be fruitful for scholars who want to undertake a systematic analysis of surveillance in the modern economy and who want to study the field of surveillance critically.

  10. Using a data fusion-based activity recognition framework to determine surveillance system requirements

    CSIR Research Space (South Africa)

    Le Roux, WH

    2007-07-01

    Full Text Available A technique is proposed to extract system requirements for a maritime area surveillance system, based on an activity recognition framework originally intended for the characterisation, prediction and recognition of intentional actions for threat...

  11. Situation exploration in a persistent surveillance system with multidimensional data

    Science.gov (United States)

    Habibi, Mohammad S.

    2013-03-01

    There is an emerging need for fusing hard and soft sensor data in an efficient surveillance system to provide accurate estimation of situation awareness. These mostly abstract, multi-dimensional and multi-sensor data pose a great challenge to the user in performing analysis of multi-threaded events efficiently and cohesively. To address this concern an interactive Visual Analytics (VA) application is developed for rapid assessment and evaluation of different hypotheses based on context-sensitive ontology spawn from taxonomies describing human/human and human/vehicle/object interactions. A methodology is described here for generating relevant ontology in a Persistent Surveillance System (PSS) and demonstrates how they can be utilized in the context of PSS to track and identify group activities pertaining to potential threats. The proposed VA system allows for visual analysis of raw data as well as metadata that have spatiotemporal representation and content-based implications. Additionally in this paper, a technique for rapid search of tagged information contingent to ranking and confidence is explained for analysis of multi-dimensional data. Lastly the issue of uncertainty associated with processing and interpretation of heterogeneous data is also addressed.

  12. DASH - Youth Risk Behavior Surveillance System (YRBSS): High School - Excluding Sexual Identity

    Data.gov (United States)

    U.S. Department of Health & Human Services — 1991-2015. High School Dataset. The Youth Risk Behavior Surveillance System (YRBSS) monitors six categories of priority health behaviors among youth and young...

  13. Privacy preserving surveillance and the tracking-paradox

    OpenAIRE

    Greiner, S.; Birnstill, Pascal; Krempel, Erik; Beckert, B.; Beyerer, Jürgen

    2013-01-01

    Increasing capabilities of intelligent video surveillance systems impose new threats to privacy while, at the same time, offering opportunities for reducing the privacy invasiveness of surveillance measures as well as their selectivity. We show that aggregating more data about observed people does not necessarily lead to less privacy, but can increase the selectivity of surveillance measures. In case of video surveillance in a company environment, if we enable the system to authenticate emplo...

  14. Transition to CCTV surveillance for safeguards

    International Nuclear Information System (INIS)

    Gaertner, K.J.; Heaysman, B.; Kerr, R.E.; Rundquist, D.E.

    1987-01-01

    After many years of development effort and as a result of regular maintenance the Agency's most important optical surveillance system, the Twin Minolta, has matured to a highly reliable, economic and user friendly equipment. In 1986 its reliability was 95.7%, including human failures. However, because they are no longer available, the Agency is forced to replace the Minolta Super 8 cameras by adequate Closed Circuit Television systems. Ten years of experience with television systems clearly indicate that they must work actively to improve the overall reliability of CCTV systems. The recording units, from the authors experience, are the most critical components. Therefore new systems - already existing or under development - focus on this aspect. The Multiplex TV Surveillance System (MUX), uses redundant time lapse recorders, which are specifically designed for surveillance applications. The Compact Surveillance Monitoring System (COSMOS) will be using low speed time lapse recorders which are specifically developed for still-picture recording surveillance applications. The Modular Integrated Video System (MIVS) will use two redundant 8 mm video recorders to achieve the goal of high reliability. It is their understanding that this intensive consideration of reliability aspects in the design phase will also result in a decrease in maintenance and operational costs for the Agency in the future

  15. Intelligent agents for adaptive security market surveillance

    Science.gov (United States)

    Chen, Kun; Li, Xin; Xu, Baoxun; Yan, Jiaqi; Wang, Huaiqing

    2017-05-01

    Market surveillance systems have increasingly gained in usage for monitoring trading activities in stock markets to maintain market integrity. Existing systems primarily focus on the numerical analysis of market activity data and generally ignore textual information. To fulfil the requirements of information-based surveillance, a multi-agent-based architecture that uses agent intercommunication and incremental learning mechanisms is proposed to provide a flexible and adaptive inspection process. A prototype system is implemented using the techniques of text mining and rule-based reasoning, among others. Based on experiments in the scalping surveillance scenario, the system can identify target information evidence up to 87.50% of the time and automatically identify 70.59% of cases depending on the constraints on the available information sources. The results of this study indicate that the proposed information surveillance system is effective. This study thus contributes to the market surveillance literature and has significant practical implications.

  16. Space vehicle field unit and ground station system

    Science.gov (United States)

    Judd, Stephen; Dallmann, Nicholas; Delapp, Jerry; Proicou, Michael; Seitz, Daniel; Michel, John; Enemark, Donald

    2017-09-19

    A field unit and ground station may use commercial off-the-shelf (COTS) components and share a common architecture, where differences in functionality are governed by software. The field units and ground stations may be easy to deploy, relatively inexpensive, and be relatively easy to operate. A novel file system may be used where datagrams of a file may be stored across multiple drives and/or devices. The datagrams may be received out of order and reassembled at the receiving device.

  17. [Epidemiologic surveillance of dengue fever in the French army from 1996 to 1999].

    Science.gov (United States)

    Meynard, J B; Ollivier-Gay, L; Deparis, X; Durand, J P; Michel, R; Pages, F; Matton, T; Boutin, J P; Tolou, H; Merouze, F; Baudon, D

    2001-01-01

    Dengue fever is a widespread disease that can occur outside tropical areas. Several thousand French military personnel are exposed to this infectious risk each year and exposure is expected to rise with the creation of a professional army and the increasing number of foreign missions. As a result, dengue fever has become a major priority for the Armed Services Health Corps (ASHC). A system of epidemiological surveillance based on the active participation of all military physicians has been designed by the ASHC to collect and analyze all data relevant to cases of dengue fever involving French military personnel stationed overseas or at home. The purpose of this study is to present data compiled for the period from 1996 to 1999. Analysis of these data demonstrated that the incidence of dengue fever peaked in 1997 due to epidemic outbreaks occurring in French Polynesia and Martinique. In response to these outbreaks control measures were adapted especially in regard to vector control. This study shows that the system of surveillance implemented by the ASHC is an effective but still perfectible tool.

  18. Space station communications and tracking equipment management/control system

    Science.gov (United States)

    Kapell, M. H.; Seyl, J. W.

    1982-01-01

    Design details of a communications and tracking (C and T) local area network and the distribution system requirements for the prospective space station are described. The hardware will be constructed of LRUs, including those for baseband, RF, and antenna subsystems. It is noted that the C and T equipment must be routed throughout the station to accommodate growth of the station. Configurations of the C and T modules will therefore be dependent on the function of the space station module where they are located. A block diagram is provided of a sample C and T hardware distribution configuration. A topology and protocol will be needed to accommodate new terminals, wide bandwidths, bidirectional message transmission, and distributed functioning. Consideration will be given to collisions occurring in the data transmission channels.

  19. Syndromic surveillance system based on near real-time cattle mortality monitoring.

    Science.gov (United States)

    Torres, G; Ciaravino, V; Ascaso, S; Flores, V; Romero, L; Simón, F

    2015-05-01

    Early detection of an infectious disease incursion will minimize the impact of outbreaks in livestock. Syndromic surveillance based on the analysis of readily available data can enhance traditional surveillance systems and allow veterinary authorities to react in a timely manner. This study was based on monitoring the number of cattle carcasses sent for rendering in the veterinary unit of Talavera de la Reina (Spain). The aim was to develop a system to detect deviations from expected values which would signal unexpected health events. Historical weekly collected dead cattle (WCDC) time series stabilized by the Box-Cox transformation and adjusted by the minimum least squares method were used to build the univariate cycling regression model based on a Fourier transformation. Three different models, according to type of production system, were built to estimate the baseline expected number of WCDC. Two types of risk signals were generated: point risk signals when the observed value was greater than the upper 95% confidence interval of the expected baseline, and cumulative risk signals, generated by a modified cumulative sum algorithm, when the cumulative sums of reported deaths were above the cumulative sum of expected deaths. Data from 2011 were used to prospectively validate the model generating seven risk signals. None of them were correlated to infectious disease events but some coincided, in time, with very high climatic temperatures recorded in the region. The harvest effect was also observed during the first week of the study year. Establishing appropriate risk signal thresholds is a limiting factor of predictive models; it needs to be adjusted based on experience gained during the use of the models. To increase the sensitivity and specificity of the predictions epidemiological interpretation of non-specific risk signals should be complemented by other sources of information. The methodology developed in this study can enhance other existing early detection

  20. Insights from a Systematic Search for Information on Designs, Costs, and Effectiveness of Poliovirus Environmental Surveillance Systems.

    Science.gov (United States)

    Duintjer Tebbens, Radboud J; Zimmermann, Marita; Pallansch, Mark A; Thompson, Kimberly M

    2017-12-01

    Poliovirus surveillance plays a critical role in achieving and certifying eradication and will play a key role in the polio endgame. Environmental surveillance can provide an opportunity to detect circulating polioviruses prior to the observation of any acute flaccid paralysis cases. We completed a systematic review of peer-reviewed publications on environmental surveillance for polio including the search terms "environmental surveillance" or "sewage," and "polio," "poliovirus," or "poliomyelitis," and compared characteristics of the resulting studies. The review included 146 studies representing 101 environmental surveillance activities from 48 countries published between 1975 and 2016. Studies reported taking samples from sewage treatment facilities, surface waters, and various other environmental sources, although they generally did not present sufficient details to thoroughly evaluate the sewage systems and catchment areas. When reported, catchment areas varied from 50 to over 7.3 million people (median of 500,000 for the 25% of activities that reported catchment areas, notably with 60% of the studies not reporting this information and 16% reporting insufficient information to estimate the catchment area population size). While numerous studies reported the ability of environmental surveillance to detect polioviruses in the absence of clinical cases, the review revealed very limited information about the costs and limited information to support quantitative population effectiveness of conducting environmental surveillance. This review motivates future studies to better characterize poliovirus environmental surveillance systems and the potential value of information that they may provide in the polio endgame.

  1. 75 FR 81512 - Airworthiness Directives; Various Aviation Communication & Surveillance Systems (ACSS) Traffic...

    Science.gov (United States)

    2010-12-28

    ... units. This proposed AD would require upgrading software. This proposed AD results from reports of anomalies with TCAS units during a flight test over a high density airport. The TCAS units dropped several... & Surveillance Systems (ACSS) Traffic Alert and Collision Avoidance System (TCAS) units during a flight test over...

  2. Using plasma-fuel systems at Eurasian coal-fired thermal power stations

    Science.gov (United States)

    Karpenko, E. I.; Karpenko, Yu. E.; Messerle, V. E.; Ustimenko, A. B.

    2009-06-01

    The development of plasma technology for igniting solid fuels at coal-fired thermal power stations in Russia, Kazakhstan, China, and other Eurasian countries is briefly reviewed. Basic layouts and technical and economic characteristics of plasma-fuel systems installed in different coal-fired boiles are considered together with some results from using these systems at coal-fired thermal power stations.

  3. Evaluation of a radioactive aerosol surveillance system

    International Nuclear Information System (INIS)

    Scripsick, R.C.; Stafford, R.G.; Beckman, R.J.; Tillery, M.I.; Romero, P.O.

    Measurements of the dilution of air contaminants between worker breathing zone and area air samplers were made by releasing a test aerosol in a workroom equipped with an aerosol surveillance system. The data were used to evaluate performance, and suggest improvements in design of the workroom's alarming air monitor system. It was found that a breathing zone concentration of 960 times the maximum permissible concentration in air (MPC/sub a/) for a half-hour was required to trigger alarms of the existing monitoring system under some release conditions. Alternative air monitor placement, suggested from dilution measurements, would reduce this average triggering concentration to 354 MPC/sub a/. Deployment of additional air monitors could further reduce the average triggering concentration to 241 MPC/sub a/. The relation between number of monitors and triggering concentration was studied. No significant decrease in average triggering concentration was noted for arrays containing greater than five monitors

  4. Practical experience with a local verification system for containment and surveillance sensors

    International Nuclear Information System (INIS)

    Lauppe, W.D.; Richter, B.; Stein, G.

    1984-01-01

    With the growing number of nuclear facilities and a number of large commercial bulk handling facilities steadily coming into operation the International Atomic Energy Agency is faced with increasing requirements as to reducing its inspection efforts. One means of meeting these requirements will be to deploy facility based remote interrogation methods for its containment and surveillance instrumentation. Such a technical concept of remote interrogation was realized through the so-called LOVER system development, a local verification system for electronic safeguards seal systems. In the present investigations the application was extended to radiation monitoring by introducing an electronic interface between the electronic safeguards seal and the neutron detector electronics of a waste monitoring system. The paper discusses the safeguards motivation and background, the experimental setup of the safeguards system and the performance characteristics of this LOVER system. First conclusions can be drawn from the performance results with respect to the applicability in international safeguards. This comprises in particular the definition of design specifications for an integrated remote interrogation system for various types of containment and surveillance instruments and the specifications of safeguards applications employing such a system

  5. SCORPION II persistent surveillance system update

    Science.gov (United States)

    Coster, Michael; Chambers, Jon

    2010-04-01

    This paper updates the improvements and benefits demonstrated in the next generation Northrop Grumman SCORPION II family of persistent surveillance and target recognition systems produced by the Xetron Campus in Cincinnati, Ohio. SCORPION II reduces the size, weight, and cost of all SCORPION components in a flexible, field programmable system that is easier to conceal and enables integration of over fifty different Unattended Ground Sensor (UGS) and camera types from a variety of manufacturers, with a modular approach to supporting multiple Line of Sight (LOS) and Beyond Line of Sight (BLOS) communications interfaces. Since 1998 Northrop Grumman has been integrating best in class sensors with its proven universal modular Gateway to provide encrypted data exfiltration to Common Operational Picture (COP) systems and remote sensor command and control. In addition to feeding COP systems, SCORPION and SCORPION II data can be directly processed using a common sensor status graphical user interface (GUI) that allows for viewing and analysis of images and sensor data from up to seven hundred SCORPION system gateways on single or multiple displays. This GUI enables a large amount of sensor data and imagery to be used for actionable intelligence as well as remote sensor command and control by a minimum number of analysts.

  6. A Categorization of Converter Station Controllers Within Multi-terminal DC Transmission Systems

    DEFF Research Database (Denmark)

    Irnawan, Roni; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2016-01-01

    of controller might exist in the same system. It is therefore important to identify the parameters required by the converter station controllers to ensure a smooth coordination. In this paper, different converter station controllers available in the literatures are categorized. Challenges of converter station...

  7. Distributed operating system for NASA ground stations

    Science.gov (United States)

    Doyle, John F.

    1987-01-01

    NASA ground stations are characterized by ever changing support requirements, so application software is developed and modified on a continuing basis. A distributed operating system was designed to optimize the generation and maintenance of those applications. Unusual features include automatic program generation from detailed design graphs, on-line software modification in the testing phase, and the incorporation of a relational database within a real-time, distributed system.

  8. Microprocessor-based integrated LMFBR core surveillance. Pt. 2

    International Nuclear Information System (INIS)

    Elies, V.

    1985-12-01

    This report is the result of the KfK part of a joint study of KfK and INTERATOM. The aim of this study is to explore the advantages of microprocessors and microelectronics for a more sophisticated core surveillance, which is based on the integration of separate surveillance techniques. After a description of the experimental results gained with the different surveillance techniques so far, it is shown which kinds of correlation can be done using the evaluation results obtained from the single surveillance systems. The main part of this report contains the systems analysis of a microcomputer-based system integrating different surveillance methods. After an analysis of the hardware requirements a hardware structure for the integrated system is proposed. The software structure is then described for the subsystem performing the different surveillance algorithms as well as for the system which does the correlation thus deriving additional information from the single results. (orig.) [de

  9. Evaluation of the national Notifiable Diseases Surveillance System for dengue fever in Taiwan, 2010-2012.

    Directory of Open Access Journals (Sweden)

    Caoimhe McKerr

    2015-03-01

    Full Text Available In Taiwan, around 1,500 cases of dengue fever are reported annually and incidence has been increasing over time. A national web-based Notifiable Diseases Surveillance System (NDSS has been in operation since 1997 to monitor incidence and trends and support case and outbreak management. We present the findings of an evaluation of the NDSS to ascertain the extent to which dengue fever surveillance objectives are being achieved.We extracted the NDSS data on all laboratory-confirmed dengue fever cases reported during 1 January 2010 to 31 December 2012 to assess and describe key system attributes based on the Centers for Disease Control and Prevention surveillance evaluation guidelines. The system's structure and processes were delineated and operational staff interviewed using a semi-structured questionnaire. Crude and age-adjusted incidence rates were calculated and key demographic variables were summarised to describe reporting activity. Data completeness and validity were described across several variables.Of 5,072 laboratory-confirmed dengue fever cases reported during 2010-2012, 4,740 (93% were reported during July to December. The system was judged to be simple due to its minimal reporting steps. Data collected on key variables were correctly formatted and usable in > 90% of cases, demonstrating good data completeness and validity. The information collected was considered relevant by users with high acceptability. Adherence to guidelines for 24-hour reporting was 99%. Of 720 cases (14% recorded as travel-related, 111 (15% had an onset >14 days after return, highlighting the potential for misclassification. Information on hospitalization was missing for 22% of cases. The calculated PVP was 43%.The NDSS for dengue fever surveillance is a robust, well maintained and acceptable system that supports the collection of complete and valid data needed to achieve the surveillance objectives. The simplicity of the system engenders compliance leading to

  10. Space Station data system analysis/architecture study. Task 1: Functional requirements definition, DR-5

    Science.gov (United States)

    1985-01-01

    The initial task in the Space Station Data System (SSDS) Analysis/Architecture Study is the definition of the functional and key performance requirements for the SSDS. The SSDS is the set of hardware and software, both on the ground and in space, that provides the basic data management services for Space Station customers and systems. The primary purpose of the requirements development activity was to provide a coordinated, documented requirements set as a basis for the system definition of the SSDS and for other subsequent study activities. These requirements should also prove useful to other Space Station activities in that they provide an indication of the scope of the information services and systems that will be needed in the Space Station program. The major results of the requirements development task are as follows: (1) identification of a conceptual topology and architecture for the end-to-end Space Station Information Systems (SSIS); (2) development of a complete set of functional requirements and design drivers for the SSIS; (3) development of functional requirements and key performance requirements for the Space Station Data System (SSDS); and (4) definition of an operating concept for the SSIS. The operating concept was developed both from a Space Station payload customer and operator perspective in order to allow a requirements practicality assessment.

  11. Ebola Surveillance - Guinea, Liberia, and Sierra Leone.

    Science.gov (United States)

    McNamara, Lucy A; Schafer, Ilana J; Nolen, Leisha D; Gorina, Yelena; Redd, John T; Lo, Terrence; Ervin, Elizabeth; Henao, Olga; Dahl, Benjamin A; Morgan, Oliver; Hersey, Sara; Knust, Barbara

    2016-07-08

    Developing a surveillance system during a public health emergency is always challenging but is especially so in countries with limited public health infrastructure. Surveillance for Ebola virus disease (Ebola) in the West African countries heavily affected by Ebola (Guinea, Liberia, and Sierra Leone) faced numerous impediments, including insufficient numbers of trained staff, community reticence to report cases and contacts, limited information technology resources, limited telephone and Internet service, and overwhelming numbers of infected persons. Through the work of CDC and numerous partners, including the countries' ministries of health, the World Health Organization, and other government and nongovernment organizations, functional Ebola surveillance was established and maintained in these countries. CDC staff were heavily involved in implementing case-based surveillance systems, sustaining case surveillance and contact tracing, and interpreting surveillance data. In addition to helping the ministries of health and other partners understand and manage the epidemic, CDC's activities strengthened epidemiologic and data management capacity to improve routine surveillance in the countries affected, even after the Ebola epidemic ended, and enhanced local capacity to respond quickly to future public health emergencies. However, the many obstacles overcome during development of these Ebola surveillance systems highlight the need to have strong public health, surveillance, and information technology infrastructure in place before a public health emergency occurs. Intense, long-term focus on strengthening public health surveillance systems in developing countries, as described in the Global Health Security Agenda, is needed.The activities summarized in this report would not have been possible without collaboration with many U.S and international partners (http://www.cdc.gov/vhf/ebola/outbreaks/2014-west-africa/partners.html).

  12. Elementary Surveillance (ELS) and Enhanced Surveillance (EHS) Validation via Mode S Secondary Radar Surveillance

    National Research Council Canada - National Science Library

    Grappel, Robert D; Harris, Garrett S; Kozar, Mark J; Wiken, Randall T

    2008-01-01

    ...) and Enhanced Surveillance (ERS) data link applications. The intended audience for this report is an engineering staff assigned the task of implementing a monitoring system used to determine ELS and EHS compliance...

  13. Information management in Iranian Maternal Mortality Surveillance System.

    Science.gov (United States)

    Sadoughi, Farahnaz; Karimi, Afsaneh; Erfannia, Leila

    2017-07-01

    Maternal mortality is preventable by proper information management and is the main target of the Maternal Mortality Surveillance System (MMSS). This study aimed to determine the status of information management in the Iranian Maternal Mortality Surveillance System (IMMSS). The population of this descriptive and analytical study, which was conducted in 2016, included 96 administrative staff of health and treatment deputies of universities of medical sciences and the Ministry of Health in Iran. Data were gathered by a five-part questionnaire with confirmed validity and reliability. A total of 76 questionnaires were completed, and data were analyzed using SPSS software, version 19, by descriptive and inferential statistics. The relationship between variables "organizational unit" and the four studied axes was studied using Kendall's correlation coefficient test. The status of information management in IMMSS was desirable. Data gathering and storage axis and data processing and compilation axis achieved the highest (2.7±0.46) and the lowest (2.4±0.49) mean scores, respectively. The data-gathering method, control of a sample of women deaths in reproductive age in the universities of medical sciences, use of international classification of disease, and use of this system information by management teams to set resources allocation achieved the lowest mean scores in studied axes. Treatment deputy staff had a more positive attitude toward the status of information management of IMMSS than the health deputy staff (p=0.004). Although the status of information management in IMMSS was desirable, it could be improved by modification of the data-gathering method; creating communication links between different data resources; a periodic sample control of women deaths in reproductive age in the universities of medical sciences; and implementing ICD-MM and integration of its rules on a unified system of death.

  14. Wisconsin’s Environmental Public Health Tracking Network: Information Systems Design for Childhood Cancer Surveillance

    Science.gov (United States)

    Hanrahan, Lawrence P.; Anderson, Henry A.; Busby, Brian; Bekkedal, Marni; Sieger, Thomas; Stephenson, Laura; Knobeloch, Lynda; Werner, Mark; Imm, Pamela; Olson, Joseph

    2004-01-01

    In this article we describe the development of an information system for environmental childhood cancer surveillance. The Wisconsin Cancer Registry annually receives more than 25,000 incident case reports. Approximately 269 cases per year involve children. Over time, there has been considerable community interest in understanding the role the environment plays as a cause of these cancer cases. Wisconsin’s Public Health Information Network (WI-PHIN) is a robust web portal integrating both Health Alert Network and National Electronic Disease Surveillance System components. WI-PHIN is the information technology platform for all public health surveillance programs. Functions include the secure, automated exchange of cancer case data between public health–based and hospital-based cancer registrars; web-based supplemental data entry for environmental exposure confirmation and hypothesis testing; automated data analysis, visualization, and exposure–outcome record linkage; directories of public health and clinical personnel for role-based access control of sensitive surveillance information; public health information dissemination and alerting; and information technology security and critical infrastructure protection. For hypothesis generation, cancer case data are sent electronically to WI-PHIN and populate the integrated data repository. Environmental data are linked and the exposure–disease relationships are explored using statistical tools for ecologic exposure risk assessment. For hypothesis testing, case–control interviews collect exposure histories, including parental employment and residential histories. This information technology approach can thus serve as the basis for building a comprehensive system to assess environmental cancer etiology. PMID:15471739

  15. Real-time monitoring of school absenteeism to enhance disease surveillance: a pilot study of a mobile electronic reporting system.

    Science.gov (United States)

    Lawpoolsri, Saranath; Khamsiriwatchara, Amnat; Liulark, Wongwat; Taweeseneepitch, Komchaluch; Sangvichean, Aumnuyphan; Thongprarong, Wiraporn; Kaewkungwal, Jaranit; Singhasivanon, Pratap

    2014-05-12

    School absenteeism is a common source of data used in syndromic surveillance, which can eventually be used for early outbreak detection. However, the absenteeism reporting system in most schools, especially in developing countries, relies on a paper-based method that limits its use for disease surveillance or outbreak detection. The objective of this study was to develop an electronic real-time reporting system on school absenteeism for syndromic surveillance. An electronic (Web-based) school absenteeism reporting system was developed to embed it within the normal routine process of absenteeism reporting. This electronic system allowed teachers to update students' attendance status via mobile tablets. The data from all classes and schools were then automatically sent to a centralized database for further analysis and presentation, and for monitoring temporal and spatial patterns of absent students. In addition, the system also had a disease investigation module, which provided a link between absenteeism data from schools and local health centers, to investigate causes of fever among sick students. The electronic school absenteeism reporting system was implemented in 7 primary schools in Bangkok, Thailand, with total participation of approximately 5000 students. During May-October 2012 (first semester), the percentage of absentees varied between 1% and 10%. The peak of school absenteeism (sick leave) was observed between July and September 2012, which coincided with the peak of dengue cases in children aged 6-12 years being reported to the disease surveillance system. The timeliness of a reporting system is a critical function in any surveillance system. Web-based application and mobile technology can potentially enhance the use of school absenteeism data for syndromic surveillance and outbreak detection. This study presents the factors that determine the implementation success of this reporting system.

  16. Real-Time Surveillance of Infectious Diseases: Taiwan's Experience.

    Science.gov (United States)

    Jian, Shu-Wan; Chen, Chiu-Mei; Lee, Cheng-Yi; Liu, Ding-Ping

    Integration of multiple surveillance systems advances early warning and supports better decision making during infectious disease events. Taiwan has a comprehensive network of laboratory, epidemiologic, and early warning surveillance systems with nationwide representation. Hospitals and clinical laboratories have deployed automatic reporting mechanisms since 2014 and have effectively improved timeliness of infectious disease and laboratory data reporting. In June 2016, the capacity of real-time surveillance in Taiwan was externally assessed and was found to have a demonstrated and sustainable capability. We describe Taiwan's disease surveillance system and use surveillance efforts for influenza and Zika virus as examples of surveillance capability. Timely and integrated influenza information showed a higher level and extended pattern of influenza activity during the 2015-16 season, which ensured prompt information dissemination and the coordination of response operations. Taiwan also has well-developed disease detection systems and was the first country to report imported cases of Zika virus from Miami Beach and Singapore. This illustrates a high level of awareness and willingness among health workers to report emerging infectious diseases, and highlights the robust and sensitive nature of Taiwan's surveillance system. These 2 examples demonstrate the flexibility of the surveillance systems in Taiwan to adapt to emerging infectious diseases and major communicable diseases. Through participation in the GHSA, Taiwan can more actively collaborate with national counterparts and use its expertise to strengthen global and regional surveillance capacity in the Asia Pacific and in Southeast Asia, in order to advance a world safe and secure from infectious disease.

  17. Retrofit of new digital control systems in existing power stations

    International Nuclear Information System (INIS)

    Smith, J.E.; Baird, C.F.

    1986-01-01

    With the notable exception of the Canadian CANDU nuclear power stations, little use has been made of digital control in North American nuclear stations. Recently, however, there has been renewed interest in such systems within the nuclear industry in response to demands for better ergonomics in control room design and the obsolescence of control equipment whose fundamental design has changed little in 20 yr. Early in 1985, Atomic Energy of Canada Limited was asked by New Brunswick Power to advise on the redesign of the control systems for two fossil-fired generating stations, Coleson Cove and Courtenay Bay Unit 4. Coleson Cove is to be converted from oil to coal firing with consequent extensive control system changes and Courtenay Bay Unit 4 required a low-cost solution to the problem of relocating its control room from the existing isolated location to the combined control center used by units 1, 2, and 3. In both cases, the recommended solution involves the retrofit of state-of-the-art digital control systems. Although the units involved are nonnuclear the experience is applicable

  18. Technical-evaluation report on the proposed technical-specification changes for the inservice surveillance of safety-related hydraulic and mechanical snubbers at the Millstone Nuclear Power Station, Unit 2 (Docket No. 50-336)

    International Nuclear Information System (INIS)

    Selan, J.C.

    1983-01-01

    This report documents the technical evaluation of the proposed Technical Specification changes to Limiting Conditions for Operation, Surveillance Requirements and Bases for safety-related hydraulic and mechanical snubbers at the Millstone Nuclear Power Station, Unit 2. The evaluation is to determine whether the proposed Technical Specifications are in conformance with the model Standard Technical Specification set forth by the NRC. A check list, Appendix A of this report, compares the licensee's submittal with the NRC requirements and includes Proposed Resolution of the Deviations

  19. Evaluation of community-based surveillance for Guinea worm, South ...

    African Journals Online (AJOL)

    2012-08-03

    Aug 3, 2012 ... deleted at the Data Manager Level in Loki. Conclusion. Community-based surveillance for guinea worm is a good example of a surveillance system on which an integrated disease surveillance system can be based in countries with poor surveillance like South Sudan. This makes its potential value to ...

  20. Video auto stitching in multicamera surveillance system

    Science.gov (United States)

    He, Bin; Zhao, Gang; Liu, Qifang; Li, Yangyang

    2012-01-01

    This paper concerns the problem of video stitching automatically in a multi-camera surveillance system. Previous approaches have used multiple calibrated cameras for video mosaic in large scale monitoring application. In this work, we formulate video stitching as a multi-image registration and blending problem, and not all cameras are needed to be calibrated except a few selected master cameras. SURF is used to find matched pairs of image key points from different cameras, and then camera pose is estimated and refined. Homography matrix is employed to calculate overlapping pixels and finally implement boundary resample algorithm to blend images. The result of simulation demonstrates the efficiency of our method.

  1. Functions and Requirements and Specifications for Replacement of the Computer Automated Surveillance System (CASS)

    International Nuclear Information System (INIS)

    SCAIEF, C.C.

    1999-01-01

    This functions, requirements and specifications document defines the baseline requirements and criteria for the design, purchase, fabrication, construction, installation, and operation of the system to replace the Computer Automated Surveillance System (CASS) alarm monitoring

  2. Weather-enabled future onboard surveillance and navigation systems

    Science.gov (United States)

    Mutuel, L.; Baillon, B.; Barnetche, B.; Delpy, P.

    2009-09-01

    With the increasing traffic and the development of business trajectories, there is a widespread need to anticipate any adverse weather conditions that could impact the performance of the flight or to use of atmospheric parameters to optimize trajectories. Current sensors onboard air transport are challenged to provide the required service, while new products for business jets and general aviation open the door to innovative assimilation of weather information in onboard surveillance and navigation. The paper aims at surveying current technology available to air transport aircraft and pointing out their shortcomings in view of the modernization proposed in SESAR and NextGen implementation plans. Foreseen innovations are then illustrated via results of ongoing research like FLYSAFE or standardization efforts, in particular meteorological datalink services and impact on Human-Machine Interface. The paper covers the operational need to avoid adverse weather like thunderstorm, icing, turbulence, windshear and volcanic ash, but also the requirement to control in 4D the trajectory through the integration of wind and temperature grids in the flight management. The former will lead to enhanced surveillance systems onboard the aircraft with new displays and new alerting schemes, ranging from targeted information supporting better re-planning to auto-escape strategies. The latter will be standard in next generation flight management systems. Finally both will rely on ATM products that will also assimilate weather information so that situational awareness is shared and decision is collaborative.

  3. A super base station based centralized network architecture for 5G mobile communication systems

    Directory of Open Access Journals (Sweden)

    Manli Qian

    2015-04-01

    Full Text Available To meet the ever increasing mobile data traffic demand, the mobile operators are deploying a heterogeneous network with multiple access technologies and more and more base stations to increase the network coverage and capacity. However, the base stations are isolated from each other, so different types of radio resources and hardware resources cannot be shared and allocated within the overall network in a cooperative way. The mobile operators are thus facing increasing network operational expenses and a high system power consumption. In this paper, a centralized radio access network architecture, referred to as the super base station (super BS, is proposed, as a possible solution for an energy-efficient fifth-generation (5G mobile system. The super base station decouples the logical functions and physical entities of traditional base stations, so different types of system resources can be horizontally shared and statistically multiplexed among all the virtual base stations throughout the entire system. The system framework and main functionalities of the super BS are described. Some key technologies for system implementation, i.e., the resource pooling, real-time virtualization, adaptive hardware resource allocation are also highlighted.

  4. A modular Space Station/Base electrical power system - Requirements and design study.

    Science.gov (United States)

    Eliason, J. T.; Adkisson, W. B.

    1972-01-01

    The requirements and procedures necessary for definition and specification of an electrical power system (EPS) for the future space station are discussed herein. The considered space station EPS consists of a replaceable main power module with self-contained auxiliary power, guidance, control, and communication subsystems. This independent power source may 'plug into' a space station module which has its own electrical distribution, control, power conditioning, and auxiliary power subsystems. Integration problems are discussed, and a transmission system selected with local floor-by-floor power conditioning and distribution in the station module. This technique eliminates the need for an immediate long range decision on the ultimate space base power sources by providing capability for almost any currently considered option.

  5. Technology for Space Station Evolution. Volume 3: EVA/Manned Systems/Fluid Management System

    Science.gov (United States)

    1990-01-01

    NASA's Office of Aeronautics and Space Technology (OAST) conducted a workshop on technology for space station evolution 16-19 Jan. 1990 in Dallas, Texas. The purpose of this workshop was to collect and clarify Space Station Freedom technology requirements for evolution and to describe technologies that can potentially fill those requirements. These proceedings are organized into an Executive Summary and Overview and five volumes containing the Technology Discipline Presentations. Volume 3 consists of the technology discipline sections for Extravehicular Activity/Manned Systems and the Fluid Management System. For each technology discipline, there is a Level 3 subsystem description, along with the papers.

  6. thermal power stations' reliability evaluation in a hydrothermal system

    African Journals Online (AJOL)

    Dr Obe

    A quantitative tool for the evaluation of thermal power stations reliability in a hydrothermal system is presented. ... (solar power); wind (wind power) and the rest, thermal power and ... probability of a system performing its function adequately for ...

  7. Review of occupational radiation exposures in all biennial shutdown maintenance of Kaiga generating station

    International Nuclear Information System (INIS)

    Murukan, E.K.; Vinod Kumar, T.; Austine, N.X.; Soumia Menon, M.; Girish Kumar, K.; Rao, M.M.L.N.; Venkataramana, K.

    2008-01-01

    Full text: Kaiga generating station 1 and 2 consists of twin units of 220 M We pressurized heavy water reactors located in Karnataka, India. Major maintenance activities of one of the twin units are taken up once in two years (biennial shutdown) to execute system maintenance, system up gradation, surveillance and in-service inspection (ISI) jobs. BSDs are mandatory activities to comply with regulatory requirement to ensure the safety and reliability of plant system equipment. More than 65% of the station collective dose is contributed by biennial shutdown (BSD) jobs. It is observed that the man rem consumed during normal operation of the plant is less than 35% of the total man rem consumed. Since BSD jobs contributes significantly to station collective dose, an effective implementation of radiation protection programme specific to BSD is the key to control the occupational exposure. Various improvements in the field of radiation protection practices and process systems are adopted to achieve lowest collective dose at par with international standards. The key areas identified for application of various strategies to achieve ALARA were Man rem budgeting, Radiological condition monitoring, Radiation protection practices, Identification of critical jobs and Work groups, Work planning and execution, and Radioactive waste management. Review of collective doses of all the BSD jobs performed in the station since year 2004 and various measures incorporated to achieve ALARA exposures to plant personnel are briefly discussed in this paper. (author)

  8. A home away from home. [life support system design for Space Station

    Science.gov (United States)

    Powell, L. E.; Hager, R. W.; Mccown, J. W.

    1985-01-01

    The role of the NASA-Marshall center in the development of the Space Station is discussed. The tasks of the center include the development of the life-support system; the design of the common module, which will form the basis for all pressurized Space Station modules; the design and outfit of a common module for the Material and Technology Laboratory (MTL) and logistics use; accommodations for operations of the Orbit Maneuvering Vehicle (OMV) and the Orbit Transfer Vehicle (OTV); and the Space Station propulsion system. A description of functions and design is given for each system, with particular emphasis on the goals of safety, efficiency, automation, and cost effectiveness.

  9. Effectiveness of community participation in a surveillance system initiative to prevent drowning in Thailand.

    Science.gov (United States)

    Sansiritaweesook, Getsara; Muangsom, Niramon; Kanato, Manop; Ratanasiri, Amornrat

    2015-03-01

    This study had a 2-group pre-post quasiexperimental design and was conducted in 2 selected areas of Ubon Ratchathani province, Thailand. The objective was to evaluate the extent to which the surveillance system that was developed helped in drowning prevention. The development process involved extensive participation from the community. System efficiency was evaluated, and the drowning rates were compared. The system demonstrated 82.8% system sensitivity and 87% positive-predictive value. There were 90.0% rescues with no injury during the study period. The relative risk of drowning injury suggests that the control area was at 5.6 times more at risk for drowning injury than the intervention area (95% CI = 1.58, 20.12). Local knowledge and participation from the community were found to be key issues in the success of the surveillance system, and such systems can be applied to other areas with similar problems. © 2013 APJPH.

  10. Development and piloting of the Fiji Injury Surveillance in Hospitals System (TRIP Project-1).

    Science.gov (United States)

    Wainiqolo, I; Kafoa, B; McCaig, E; Kool, B; McIntyre, R; Ameratunga, S

    2013-01-01

    Whilst more than 90% of injury related deaths are estimated to occur in low-and-middle-income countries (LMICs), the epidemiology of fatal and hospitalised injuries in Pacific Island Countries has received scant attention. This study describes the development and piloting of a population-based trauma registry in Fiji to address this gap in knowledge. The Fiji Injury Surveillance in Hospitals (FISH) system was an active surveillance system designed to identify injuries resulting in death or a hospital admission in Viti Levu, Fiji. During the pilot conducted over five months in 2005, Accident and Emergency registers, admission folders and morgue registers from 8 of Viti Levu's 12 hospitals, and an additional 3 hospitals in other parts of the country were reviewed by hospital staff and medical students to identify cases and extract a minimum data set that included demographic factors; the mechanism, nature and context of injury; substance use; and discharge outcomes. The system was audited to identify and redress difficulties with data quality in a manner that also supported local capacity development and training in injury surveillance and data management. This pilot study demonstrated the potential to collect high quality data on injuries that can pose a significant threat to life in Fiji using a mechanism that also increased the capability of health professionals to recognise the significance of injury as a public health issue. The injury surveillance system piloted provides the opportunity to inform national injury control strategies in Fiji and increase the capacity for injury prevention and more focused research addressing risk factors in the local context. Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. Cell Phone-Based System (Chaak) for Surveillance of Immatures of Dengue Virus Mosquito Vectors

    Science.gov (United States)

    LOZANO–FUENTES, SAUL; WEDYAN, FADI; HERNANDEZ–GARCIA, EDGAR; SADHU, DEVADATTA; GHOSH, SUDIPTO; BIEMAN, JAMES M.; TEP-CHEL, DIANA; GARCÍA–REJÓN, JULIÁN E.; EISEN, LARS

    2014-01-01

    Capture of surveillance data on mobile devices and rapid transfer of such data from these devices into an electronic database or data management and decision support systems promote timely data analyses and public health response during disease outbreaks. Mobile data capture is used increasingly for malaria surveillance and holds great promise for surveillance of other neglected tropical diseases. We focused on mosquito-borne dengue, with the primary aims of: 1) developing and field-testing a cell phone-based system (called Chaak) for capture of data relating to the surveillance of the mosquito immature stages, and 2) assessing, in the dengue endemic setting of Mérida, México, the cost-effectiveness of this new technology versus paper-based data collection. Chaak includes a desktop component, where a manager selects premises to be surveyed for mosquito immatures, and a cell phone component, where the surveyor receives the assigned tasks and captures the data. Data collected on the cell phone can be transferred to a central database through different modes of transmission, including near-real time where data are transferred immediately (e.g., over the Internet) or by first storing data on the cell phone for future transmission. Spatial data are handled in a novel, semantically driven, geographic information system. Compared with a pen-and-paper-based method, use of Chaak improved the accuracy and increased the speed of data transcription into an electronic database. The cost-effectiveness of using the Chaak system will depend largely on the up-front cost of purchasing cell phones and the recurring cost of data transfer over a cellular network. PMID:23926788

  12. Television system in which digitised picture signals subjected to a transform coding are transmitted from an encoding station to a decoding station

    NARCIS (Netherlands)

    1989-01-01

    Television system in which digitalized picture signals subjected to a transform coding are transmitted from an encoding station to a decoding station. In a television system a digital picture signal is subjected to a transform coding for the purpose of bit rate reduction. In order to detect motion

  13. Establishment of a Background Environmental Monitoring Station for the PNNL Campus

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, Brad G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Snyder, Sandra F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Barnett, J. Matthew [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bisping, Lynn E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rishel, Jeremy P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2014-12-01

    The environmental surveillance of background levels of radionuclides and, in particular, the siting of a background environmental surveillance (monitoring) station are examined. Many published works identify and stress the need for background monitoring; however, little definitive and comprehensive information for siting a station exists. A definition of an ideal background monitoring location and the generic criteria recommended for use in establishing such a background monitoring location are proposed. There are seven primary (mandatory) criteria described with two additional, optional criteria. The criteria are applied to the Richland, Washington (WA), Pacific Northwest National Laboratory (PNNL) Campus, which currently uses background monitoring data from the nearby Hanford Site. Eleven potential background monitoring sites were identified, with one location in Benton City, WA found to meet all of the mandatory and optional criteria. It is expected that the new sampler will be installed and operating by the end of June, 2015.

  14. Surveillance Angels

    NARCIS (Netherlands)

    Rothkrantz, L.J.M.

    2014-01-01

    The use of sensor networks has been proposed for military surveillance and environmental monitoring applications. Those systems are composed of a heterogeneous set of sensors to observe the environment. In centralised systems the observed data will be conveyed to the control room to process the

  15. Distributed systems for the protection of nuclear stations

    International Nuclear Information System (INIS)

    Jover, P.

    1980-01-01

    The advantages of distributed control systems usually mentioned are improved exploitation, cost reduction, and adaptation to changes in technology. These advantages are obviously very interesting for nuclear power plant applications, and many such systems have been proposed. This note comments on the application of the distributed system concept to protection systems - what should be distributed - and closes with a brief description of a protection system based on microprocessors for pressurized water stations being built in France. (auth) [fr

  16. The utility of information collected by occupational disease surveillance systems.

    Science.gov (United States)

    Money, A; Carder, M; Hussey, L; Agius, R M

    2015-11-01

    The Health and Occupation Research (THOR) network in the UK and the Republic of Ireland (ROI) is an integrated system of surveillance schemes collecting work-related ill-health (WRIH) data since 1989. In addition to providing information about disease incidence, trends in incidence and the identification of new hazards, THOR also operates an ad hoc data enquiry service enabling interested parties to request information about cases of WRIH reported to THOR. To examine requests for information made to a network of surveillance schemes for WRIH in the UK. Analysis via SPSS of data requests received by THOR between 2002 and 2014. A total of 631 requests were received by THOR between 2002 and 2014. Requests were predominantly submitted by participating THOR physicians (34%) and the main THOR funder-the UK Health & Safety Executive (HSE) (31%). The majority (67%) of requests were for information about work-related respiratory or skin disease with relatively few requests for other diagnoses, such as musculoskeletal or mental ill-health. Requests frequently related to a specific industry and/or occupation (42%) and/or a specific causal agent (58%). Data collected by occupational disease surveillance systems such as THOR are an extremely useful source of information, the use of which extends beyond informing government on disease incidence and trends in incidence. The data collected provide a framework that can assist a wide range of enquirers with clinical diagnoses, identification of suspected causative agents/exposures and to highlight growing risks in particular industrial and occupational sectors. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. How Can We Identify the Elimination of Infectious Diseases? Experience From an Active Measles Laboratory Surveillance System in the Republic of Korea.

    Science.gov (United States)

    Yang, Tae Un; Kang, Hae Ji; Eom, Hye Eun; Park, Young-Joon; Park, Ok; Kim, Su Jin; Nam, Jeong-Gu; Kim, Sung Soon; Jeong, Eun Kyeong

    2015-11-01

    Global efforts have markedly decreased the disease burden of vaccine-preventable diseases. Many countries have made considerable progress toward the elimination of measles. As elimination is approached, the very low incidence achieved by high vaccination coverage has underscored the need for a sensitive and timely surveillance system. In the Republic of Korea, an active laboratory surveillance system (ALSS) was implemented to supplement the existing passive surveillance system in 2006. The ALSS connects 5 major commercial laboratories and the national measles reference laboratory, where referred samples with positive or equivocal results are retested. Annually, from 2009 to 2013, 3714 suspected cases were detected through the ALSS, an expansion of 8- to 57-fold, compared with only the passive surveillance system. The ALSS, with its sensitivity and timeliness, is a reasonable strategy to supplement the existing measles surveillance system and to help identify the elimination of measles. © 2015 APJPH.

  18. Somatic surveillance: corporeal control through information networks

    OpenAIRE

    Monahan, Torin; Wall, Tyler

    2007-01-01

    Somatic surveillance is the increasingly invasive technological monitoring of and intervention into body functions. Within this type of surveillance regime, bodies are recast as nodes on vast information networks, enabling corporeal control through remote network commands, automated responses, or self-management practices. In this paper, we investigate three developments in somatic surveillance: nanotechnology systems for soldiers on the battlefield, commercial body-monitoring systems for hea...

  19. Limerick Nuclear Generating Station vibration monitoring system

    International Nuclear Information System (INIS)

    Mikulski, R.

    1988-01-01

    Philadelphia Electric Company utilizes a vibration monitoring computer system at its Limerick Nuclear Generating Station to evaluate machine performance. Performance can be evaluated through instantaneous sampling, online static and transient data. The system functions as an alarm monitor, displaying timely alarm data to the control area. The passage of time since the system's inception has been a learning period. Evaluation through continuous use has led to many enhancements in alarm handling and in the acquisition and display of machine data. Due to the system's sophistication, a routine maintenance program is a necessity. This paper describes the system's diagnostic tools and current utilization. System development and maintenance techniques will also be discussed

  20. The space station tethered elevator system

    Science.gov (United States)

    Anderson, Loren A.

    1989-01-01

    The optimized conceptual engineering design of a space station tethered elevator is presented. The elevator is an unmanned mobile structure which operates on a ten kilometer tether spanning the distance between the Space Station and a tethered platform. Elevator capabilities include providing access to residual gravity levels, remote servicing, and transportation to any point along a tether. The potential uses, parameters, and evolution of the spacecraft design are discussed. Engineering development of the tethered elevator is the result of work conducted in the following areas: structural configurations; robotics, drive mechanisms; and power generation and transmission systems. The structural configuration of the elevator is presented. The structure supports, houses, and protects all systems on board the elevator. The implementation of robotics on board the elevator is discussed. Elevator robotics allow for the deployment, retrieval, and manipulation of tethered objects. Robotic manipulators also aid in hooking the elevator on a tether. Critical to the operation of the tethered elevator is the design of its drive mechanisms, which are discussed. Two drivers, located internal to the elevator, propel the vehicle along a tether. These modular components consist of endless toothed belts, shunt-wound motors, regenerative power braking, and computer controlled linear actuators. The designs of self-sufficient power generation and transmission systems are reviewed. Thorough research indicates all components of the elevator will operate under power provided by fuel cells. The fuel cell systems will power the vehicle at seven kilowatts continuously and twelve kilowatts maximally. A set of secondary fuel cells provides redundancy in the unlikely event of a primary system failure. Power storage exists in the form of Nickel-Hydrogen batteries capable of powering the elevator under maximum loads.

  1. Effective surveillance for homeland security balancing technology and social issues

    CERN Document Server

    Flammini, Francesco; Franceschetti, Giorgio

    2013-01-01

    Effective Surveillance for Homeland Security: Balancing Technology and Social Issues provides a comprehensive survey of state-of-the-art methods and tools for the surveillance and protection of citizens and critical infrastructures against natural and deliberate threats. Focusing on current technological challenges involving multi-disciplinary problem analysis and systems engineering approaches, it provides an overview of the most relevant aspects of surveillance systems in the framework of homeland security. Addressing both advanced surveillance technologies and the related socio-ethical issues, the book consists of 21 chapters written by international experts from the various sectors of homeland security. Part I, Surveillance and Society, focuses on the societal dimension of surveillance-stressing the importance of societal acceptability as a precondition to any surveillance system. Part II, Physical and Cyber Surveillance, presents advanced technologies for surveillance. It considers developing technologie...

  2. Electrical system design and reliability at Ontario Hydro nuclear generating stations

    Energy Technology Data Exchange (ETDEWEB)

    Royce, C. J. [Ontario Hydro, 700 University Avenue, Toronto, Ontario M5G 1X6 (Canada)

    1986-02-15

    This paper provides an overview of design practice and the predicted and actual reliability of electrical station service Systems at Ontario Nuclear Generating Stations. Operational experience and licensing changes have indicated the desirability of improving reliability in certain instances. For example, the requirement to start large emergency coolant injection pumps resulted in the turbine generator units in a multi-unit station being used as a back-up power supply. Results of reliability analyses are discussed. To mitigate the effects of common mode events Ontario Hydro adopted a 'two group' approach to the design of safety related Systems. This 'two group' approach is reviewed and a single fully environmentally qualified standby power supply is proposed for future use. (author)

  3. Radiation protection in nuclear facilities. The Caise environmental surveillance system

    International Nuclear Information System (INIS)

    Witt, H. de; Voelz, E.

    1995-01-01

    The Computer Aided Surveillance System for the Environment of Nuclear Installations (Caise) has been designed for permanent surveillance of the environment of nuclear installations under normal operating conditions and for unusual events on the basis of radiological and meteorological measured data. In normal operation, the data measured on line are fed to the system by way of a defined interface, while off-line data can be entered manually in the dialog mode. Subsequently, the measured data are stored, filed away, and secured. Short-time dispersion factors can be calculated permanently in the on-line mode, while the off-line mode allows short-term and long-term dispersions to be calculated for randomly selectable periods of time under the General Administrative Rule of Sec. 45 of the German Radiation Protection Ordinance. The corresponding dose distributions in the environment of the plant can be determined next. Under conditions of increased emissions (accidents, failures), Caise assists in quick decision-making by its capacity for real-time dispersion calculations including current on-line and off-line emission sample measurements. In this way, the contributions by various different exposure pathways to the calculated dose can be determined more accurately. (orig.) [de

  4. Man-machine interface systems for the Sizewell B Nuclear Power Station

    International Nuclear Information System (INIS)

    Boettcher, D.B.

    2004-01-01

    Sizewell B is the first nuclear power station to be built in the United Kingdom using the Pressurised Water Reactor or PWR system. The design is based on stations operating in the United States, but many changes and new features have been introduced to bring it up to date, and to meet United Kingdom practice and regulatory requirements. The Man-Machine Interfaces (MMIs) in the control rooms have been newly designed from first principles, with special attention paid to human factors and the role of the operators. The instrumentation and control (1 and C) systems which interface the MMIs to the process plant, and automate the operation of the station, use advanced technology to achieve high performance and availability. This paper describes the development of the control rooms and 1 and C systems, explaining the thinking that lay behind the principal decisions. (author)

  5. HIV surveillance in MENA: recent developments and results.

    Science.gov (United States)

    Bozicevic, Ivana; Riedner, Gabriele; Calleja, Jesus Maria Garcia

    2013-11-01

    To provide an overview of the current level of development and results from the national HIV surveillance systems of the 23 countries of the Middle East and North Africa (MENA), and to assess the quality of HIV surveillance systems in the period 2007-2011. A questionnaire was used to collect the information about the structure, activities and the results of HIV surveillance systems from the National AIDS Programmes. Assessment of the quality was based on four indicators: timeliness of data collection, appropriateness of populations under surveillance, consistency of the surveillance sites and groups measured over time, and coverage of the surveillance system. Only in four countries did surveillance systems enable assessment of epidemic trends in the same populations and locations over time, such as in pregnant women (Morocco, Iran), injecting drug users (Iran, Pakistan), female sex workers (Djibouti, Morocco) and male sex workers (Pakistan). There is increasing evidence of HIV infection being firmly established in at least one of the populations most at risk of HIV in nine MENA countries, while lower risk populations show elevated HIV prevalence in South Sudan, Djibouti and some parts of Somalia. The performance of HIV surveillance systems in several of the MENA countries has improved in recent years. The extent of HIV epidemics in the populations most at risk of HIV is still largely unknown in 10 countries. Multiple data sources that most of the countries still lack would enable indirectly estimation not only of the patterns of HIV epidemics but also the effectiveness of HIV responses.

  6. Reassessing the WIC Effect: Evidence from the Pregnancy Nutrition Surveillance System

    Science.gov (United States)

    Joyce, Ted; Racine, Andrew; Yunzal-Butler, Cristina

    2008-01-01

    Recent analyses differ on how effective the Special Supplemental Nutrition Program for Women, Infants and Children (WIC) is at improving infant health. We use data from nine states that participate in the Pregnancy Nutrition Surveillance System to address limitations in previous work. With information on the mother's timing of WIC enrollment, we…

  7. Approaches to canine health surveillance.

    Science.gov (United States)

    O'Neill, Dan G; Church, David B; McGreevy, Paul D; Thomson, Peter C; Brodbelt, Dave C

    2014-01-01

    Effective canine health surveillance systems can be used to monitor disease in the general population, prioritise disorders for strategic control and focus clinical research, and to evaluate the success of these measures. The key attributes for optimal data collection systems that support canine disease surveillance are representativeness of the general population, validity of disorder data and sustainability. Limitations in these areas present as selection bias, misclassification bias and discontinuation of the system respectively. Canine health data sources are reviewed to identify their strengths and weaknesses for supporting effective canine health surveillance. Insurance data benefit from large and well-defined denominator populations but are limited by selection bias relating to the clinical events claimed and animals covered. Veterinary referral clinical data offer good reliability for diagnoses but are limited by referral bias for the disorders and animals included. Primary-care practice data have the advantage of excellent representation of the general dog population and recording at the point of care by veterinary professionals but may encounter misclassification problems and technical difficulties related to management and analysis of large datasets. Questionnaire surveys offer speed and low cost but may suffer from low response rates, poor data validation, recall bias and ill-defined denominator population information. Canine health scheme data benefit from well-characterised disorder and animal data but reflect selection bias during the voluntary submissions process. Formal UK passive surveillance systems are limited by chronic under-reporting and selection bias. It is concluded that active collection systems using secondary health data provide the optimal resource for canine health surveillance.

  8. Behavioral Risk Factor Surveillance System (BRFSS) Age-Adjusted Prevalence Data (2011 to present)

    Data.gov (United States)

    U.S. Department of Health & Human Services — 2011 to present. BRFSS combined land line and cell phone age-adjusted prevalence data. The BRFSS is a continuous, state-based surveillance system that collects...

  9. Containment and surveillance systems for international safeguards

    International Nuclear Information System (INIS)

    Ney, J.F.

    1978-01-01

    Important criteria in measuring the effectiveness of IAEA safeguards include timeliness of detection of diversion, timeliness of reporting such detections, and confidence in determining the amount of material diverted. Optimum use of IAEA inspectors, combined with adequate instrumentation, can provide a practical means for achieving these criteria. System studies are being carried out for different types of facilities that may come under IAEA safeguards to determine the proper balance between inspector's efforts and the use of safeguards instrumentation. A description of a typical study is presented. Based on the results of these studies, the program undertaken to develop those containment and surveillance subsystems for which the technical feasibility and operational acceptability need to be established is described

  10. Hydraulic oil control system for transformer stations

    International Nuclear Information System (INIS)

    Truong, P.

    2002-01-01

    'Full text:' Electrical oil control systems are commonly used to contain large volumes of spilled oil in transformer stations. Specially calibrated floats, some of which are designed to float only in oil and others only in water, are used in combination with a pump to contain oil at the catch basin below a transformer station.This electrical control system requires frequent maintenance and inspections to ensure the electrical system is not affected by any electrical surges. Also the floats need to be inspected and cleaned frequently to prevent oil or grit build up that may affect the systems' ability to contain oil.Recognizing the limitations of electrical oil control systems, Hydro One is investigating alternative control systems. A hydraulic oil control system is being investigated as an alternative which can backup oil in a containment area while allowing any water entering the containment area to pass through. Figure 1 shows a schematic of a bench-top model tested at Ryerson University. Oil and water separation occurs within the double-piped column. Oil and water are allowed to enter the external pipe column but only water is allowed to exit the internal pipe column. The internal pipe column is designed to generate enough hydrostatic pressure to ensure the oil is contained in the external pipe column.The hydraulic oil control system provides a reliable control mechanism and requires less maintenance compared to that of the electrical control system. Since the hydraulic oil control system has no moving parts, nor would any parts that require electricity, it is not affected by electrical surges such as lightening.The maintenance requirements of the hydraulic oil control system are: the removal of any oil and grit from the catch basin, and the occasional visual inspection for any crack or clogs in the system. (author)

  11. Flow Control and Design Assessment for Drainage System at McMurdo Station, Antarctica

    Science.gov (United States)

    2014-11-24

    Drainage System at McMurdo Station, Antarctica Co ld R eg io ns R es ea rc h an d En gi ne er in g La bo ra to ry Rosa Affleck, Meredith...Flow Control and Design Assessment for Drainage System at McMurdo Station, Antarctica Rosa Affleck, Meredith Carr, and Brendan West Cold Regions...Characterization and Variations at McMurdo Station, Antarctica . ERDC/CRREL TR-14-6. Hanover, NH: U.S. Army Engineer Research and Development Center

  12. The value of information: Current challenges in surveillance implementation.

    Science.gov (United States)

    Stärk, Katharina D C; Häsler, Barbara

    2015-11-01

    Animal health surveillance is a complex activity that involves multiple stakeholders and provides decision support across sectors. Despite progress in the design of surveillance systems, some technical challenges remain, specifically for emerging hazards. Surveillance can also be impacted by political interests and costly consequences of case reporting, particularly in relation to international trade. Constraints on surveillance can therefore be of technical, economic and political nature. From an economic perspective, both surveillance and intervention are resource-using activities that are part of a mitigation strategy. Surveillance provides information for intervention decisions and thereby helps to offset negative effects of animal disease and to reduce the decision uncertainty associated with choices on disease control. It thus creates monetary and non-monetary benefits, both of which may be challenging to quantify. The technical relationships between surveillance, intervention and loss avoidance have not been established for most hazards despite being important consideration for investment decisions. Therefore, surveillance cannot just be maximised to minimise intervention costs. Economic appraisals of surveillance need to be done on a case by case basis for any hazard considering both surveillance and intervention performance, the losses avoided and the values attached to them. This can be achieved by using an evaluation approach which provides a systematic investigation of the worth or merit of surveillance activities. Evaluation is driven by a specific evaluation question which for surveillance systems commonly considers effectiveness, efficiency, implementation and/or compliance issues. More work is needed to provide guidance on the appropriate selection of evaluation attributes and general good practice in surveillance evaluation. Due to technical challenges, economic constraints and variable levels of capacity, the implementation of surveillance systems

  13. Estimation of the sensitivity of the surveillance system for avian influenza in the western region of Cuba.

    Science.gov (United States)

    Ferrer, Edyniesky; Calistri, Paolo; Fonseca, Osvaldo; Ippoliti, Carla; Alfonso, Pastor; Iannetti, Simona; Abeledo, María A; Fernández, Octavio; Percedo, María I; Pérez, Antonio

    2013-01-01

    Although avian influenza (AI) virus of H5 and H7 subtypes has the potential to mutate to a highly pathogenic form and cause very high mortalities in some poultry species, most AI infections in poultry are due to low pathogenic AI (LPAI). Hence serological surveys, coupled with passive surveillance activities, are essential to detect sub-clinical infections by LPAI viruses, H5 and H7 subtypes. However the proper planning of an active surveillance system should be based on a careful estimation of its performance. Therefore, the sensitivity of the active surveillance system for AI in the western region of Cuba was assessed by a stochastic model quantifying the probability of revealing at least one animal infected by H5 or H7 subtype. The diagnostic sensitivity of the haemagglutination inhibition assay and different levels of within-flock prevalence (5%, 12% and 30%) were considered. The sensitivity of the surveillance system was then assessed under five different samples size scenarios: testing 20, 30, 40, 50 or 60 animals in each flock. Poultry flock sites in the western region of Cuba with a size ranging from 10,000 to 335,000 birds were included in the study.

  14. Infectious disease surveillance for the London 2012 Olympic and Paralympic Games.

    Science.gov (United States)

    Severi, E; Heinsbroek, E; Watson, C; Catchpole, M

    2012-08-02

    The London 2012 Olympic and Paralympic Games will be one of the largest mass gathering events in British history. In order to minimise potential infectious disease threats related to the event, the Health Protection Agency (HPA) has set up a suite of robust and multisource surveillance systems. These include enhancements of already established systems (notification of infectious diseases, local and regional reporting,laboratory surveillance, mortality surveillance, international surveillance, and syndromic surveillance in primary care), as well as new systems created for the Games (syndromic surveillance in emergency departments and out-of-hours/unscheduled care,undiagnosed serious infectious illness surveillance).Enhanced existing and newly established surveillance systems will continue after the Games or will be ready for future reactivation should the need arise. In addition to the direct improvements to surveillance, the strengthening of relationships with national and international stakeholders will constitute a major post-Games legacy for the HPA.

  15. Adverse reactions to cosmetic products and the Notification System in Health Surveillance: a survey.

    Science.gov (United States)

    Huf, Gisele; Rito, Priscila da Nobrega; Presgrave, Rosaura de Farias; Boas, Maria Helena Simoes Villas

    2013-12-01

    This paper is part of a study that investigates the quality of cosmetic products and evaluates the cosmetic surveillance system. This study presents the results of a research that aimed to describe the point of view of the population in terms of the prevalence of Adverse Reactions (AR) and information about the surveillance system. A structured questionnaire was applied to a random sample of 200 people from the administrative staff of the Municipal Guard of Rio de Janeiro. 38% of the participants declared AR to some cosmetic product used in the past two years. To our knowledge, this is an unpublished study in Brazil, which presents results regarding the estimated prevalence of AR similarly to international studies.

  16. Standardized rendering from IR surveillance motion imagery

    Science.gov (United States)

    Prokoski, F. J.

    2014-06-01

    Government agencies, including defense and law enforcement, increasingly make use of video from surveillance systems and camera phones owned by non-government entities.Making advanced and standardized motion imaging technology available to private and commercial users at cost-effective prices would benefit all parties. In particular, incorporating thermal infrared into commercial surveillance systems offers substantial benefits beyond night vision capability. Face rendering is a process to facilitate exploitation of thermal infrared surveillance imagery from the general area of a crime scene, to assist investigations with and without cooperating eyewitnesses. Face rendering automatically generates greyscale representations similar to police artist sketches for faces in surveillance imagery collected from proximate locations and times to a crime under investigation. Near-realtime generation of face renderings can provide law enforcement with an investigation tool to assess witness memory and credibility, and integrate reports from multiple eyewitnesses, Renderings can be quickly disseminated through social media to warn of a person who may pose an immediate threat, and to solicit the public's help in identifying possible suspects and witnesses. Renderings are pose-standardized so as to not divulge the presence and location of eyewitnesses and surveillance cameras. Incorporation of thermal infrared imaging into commercial surveillance systems will significantly improve system performance, and reduce manual review times, at an incremental cost that will continue to decrease. Benefits to criminal justice would include improved reliability of eyewitness testimony and improved accuracy of distinguishing among minority groups in eyewitness and surveillance identifications.

  17. Experiences From Developing and Upgrading a Web-Based Surveillance System for Malaria Elimination in Cambodia.

    Science.gov (United States)

    Fu, Clementine; Lopes, Sérgio; Mellor, Steve; Aryal, Siddhi; Sovannaroth, Siv; Roca-Feltrer, Arantxa

    2017-06-14

    Strengthening the surveillance component is key toward achieving country-wide malaria elimination in Cambodia. A Web-based upgraded malaria information system (MIS) was deemed to essentially act as the central component for surveillance strengthening. New functionality (eg, data visualization) and operational (eg, data quality) attributes of the system received particular attention. However, building from the lessons learned in previous systems' developments, other aspects unique to Cambodia were considered to be equally important; for instance, feasibility issues, particularly at the field level (eg, user acceptability at various health levels), and sustainability needs (eg, long-term system flexibility). The Cambodian process of identifying the essential changes and critical attributes for this new information system can provide a model for other countries at various stages of the disease control and elimination continuum. Sharing these experiences not only facilitates the establishment of "best practices" but also accelerates global and regional malaria elimination efforts. In this article, Cambodia's experience in developing and upgrading its MIS to remain responsive to country-specific needs demonstrates the necessity for considering functionality, operationalization, feasibility, and sustainability of an information system in the context of malaria elimination. ©Clementine Fu, Sérgio Lopes, Steve Mellor, Siddhi Aryal, Siv Sovannaroth, Arantxa Roca-Feltrer. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 14.06.2017.

  18. Microprocessor-based integrated LMFBR core surveillance

    International Nuclear Information System (INIS)

    Gmeiner, L.

    1984-06-01

    This report results from a joint study of KfK and INTERATOM. The aim of this study is to explore the advantages of microprocessors and microelectronics for a more sophisticated core surveillance, which is based on the integration of separate surveillance techniques. Due to new developments in microelectronics and related software an approach to LMFBR core surveillance can be conceived that combines a number of measurements into a more intelligent decision-making data processing system. The following techniques are considered to contribute essentially to an integrated core surveillance system: - subassembly state and thermal hydraulics performance monitoring, - temperature noise analysis, - acoustic core surveillance, - failure characterization and failure prediction based on DND- and cover gas signals, and - flux tilting techniques. Starting from a description of these techniques it is shown that by combination and correlation of these individual techniques a higher degree of cost-effectiveness, reliability and accuracy can be achieved. (orig./GL) [de

  19. A surveillance sector review applied to infectious diseases at a country level

    Directory of Open Access Journals (Sweden)

    Easther Sally

    2010-06-01

    Full Text Available Abstract Background The new International Health Regulations (IHR require World Health Organization (WHO member states to assess their core capacity for surveillance. Such reviews also have the potential to identify important surveillance gaps, improve the organisation of disparate surveillance systems and to focus attention on upstream hazards, determinants and interventions. Methods We developed a surveillance sector review method for evaluating all of the surveillance systems and related activities across a sector, in this case those concerned with infectious diseases in New Zealand. The first stage was a systematic description of these surveillance systems using a newly developed framework and classification system. Key informant interviews were conducted to validate the available information on the systems identified. Results We identified 91 surveillance systems and related activities in the 12 coherent categories of infectious diseases examined. The majority (n = 40 or 44% of these were disease surveillance systems. They covered all categories, particularly for more severe outcomes including those resulting in death or hospitalisations. Except for some notifiable diseases and influenza, surveillance of less severe, but important infectious diseases occurring in the community was largely absent. There were 31 systems (34% for surveillance of upstream infectious disease hazards, including risk and protective factors. This area tended to have many potential gaps and lack integration, partly because such systems were operated by a range of different agencies, often outside the health sector. There were fewer surveillance systems for determinants, including population size and characteristics (n = 9, and interventions (n = 11. Conclusions It was possible to create and populate a workable framework for describing all the infectious diseases surveillance systems and related activities in a single developed country and to identify potential

  20. Space Station Freedom regenerative water recovery system configuration selection

    Science.gov (United States)

    Reysa, R.; Edwards, J.

    1991-01-01

    The Space Station Freedom (SSF) must recover water from various waste water sources to reduce 90 day water resupply demands for a four/eight person crew. The water recovery system options considered are summarized together with system configuration merits and demerits, resource advantages and disadvantages, and water quality considerations used to select the SSF water recovery system.

  1. Converting Mosquito Surveillance to Arbovirus Surveillance with Honey-Baited Nucleic Acid Preservation Cards.

    Science.gov (United States)

    Flies, Emily J; Toi, Cheryl; Weinstein, Philip; Doggett, Stephen L; Williams, Craig R

    2015-07-01

    Spatially and temporally accurate information about infectious mosquito distribution allows for pre-emptive public health interventions that can reduce the burden of mosquito-borne infections on human populations. However, the labile nature of arboviruses, the low prevalence of infection in mosquitoes, the expensive labor costs for mosquito identification and sorting, and the specialized equipment required for arbovirus testing can obstruct arbovirus surveillance efforts. The recently developed techniques of testing mosquito expectorate using honey-baited nucleic acid preservation cards or sugar bait stations allows a sensitive method of testing for infectious, rather than infected, mosquito vectors. Here we report the results from the first large-scale incorporation of honey-baited cards into an existing mosquito surveillance program. During 4 months of the peak virus season (January-April, 2014) for a total of 577 trap nights, we set CO2-baited encephalitis vector survey (EVS) light traps at 88 locations in South Australia. The collection container for the EVS trap was modified to allow for the placement of a honey-baited nucleic acid preservation card (FTA™ card) inside. After collection, mosquitoes were maintained in a humid environment and allowed access to the cards for 1 week. Cards were then analyzed for common endemic Australian arboviruses using a nested RT-PCR. Eighteen virus detections, including 11 Ross River virus, four Barmah Forest virus, and three Stratford virus (not previously reported from South Australia) were obtained. Our findings suggest that adding FTA cards to an existing mosquito surveillance program is a rapid and efficient way of detecting infectious mosquitoes with high spatial resolution.

  2. A novel framework for intelligent surveillance system based on abnormal human activity detection in academic environments.

    Science.gov (United States)

    Al-Nawashi, Malek; Al-Hazaimeh, Obaida M; Saraee, Mohamad

    2017-01-01

    Abnormal activity detection plays a crucial role in surveillance applications, and a surveillance system that can perform robustly in an academic environment has become an urgent need. In this paper, we propose a novel framework for an automatic real-time video-based surveillance system which can simultaneously perform the tracking, semantic scene learning, and abnormality detection in an academic environment. To develop our system, we have divided the work into three phases: preprocessing phase, abnormal human activity detection phase, and content-based image retrieval phase. For motion object detection, we used the temporal-differencing algorithm and then located the motions region using the Gaussian function. Furthermore, the shape model based on OMEGA equation was used as a filter for the detected objects (i.e., human and non-human). For object activities analysis, we evaluated and analyzed the human activities of the detected objects. We classified the human activities into two groups: normal activities and abnormal activities based on the support vector machine. The machine then provides an automatic warning in case of abnormal human activities. It also embeds a method to retrieve the detected object from the database for object recognition and identification using content-based image retrieval. Finally, a software-based simulation using MATLAB was performed and the results of the conducted experiments showed an excellent surveillance system that can simultaneously perform the tracking, semantic scene learning, and abnormality detection in an academic environment with no human intervention.

  3. The Marine Corps Needs a Targeting, Sensors, and Surveillance Systems Operational Integration and Support Team

    Science.gov (United States)

    2010-03-02

    triggerman is probably still close ; lately all IEDs in the area have been initiated via command-wire. The squad leader sets a cordon, ensures an IED 9...Operational Surveillance System (G-BOSS) with a Class IIIb laser pointer. This class of laser requires users to receive a laser safety class...2) The Keyhole kit of surveillance equipment. Designed to provide “snipers with an increased capability to visually detect the enemy emplacing IEDs

  4. Commissioning and operation of the CEBAF end station refrigeration system

    International Nuclear Information System (INIS)

    Arenius, D.; Bevins, B.; Chronis, W.C.; Ganni, V.

    1996-01-01

    The CEBAF End Station Helium Refrigerator (ESR) System provides refrigeration at 80 K, 20 K and 4.5 K to three End Station experimental halls. The facility consists of a two stage helium screw compressor system, 4.5 K refrigerator, cryogen distribution valve box, and transfer lines to the individual experimental halls. The 4.5 K cold box and compressors were originally part of the ESCAR 1500 W, 4 K refrigeration system at Lawrence Berkeley Laboratory which was first commissioned in 1977. The compressors, 4.5 K cold box, and control system design were modified to adapt the plant for the requirements of the CEBAF experimental halls. Additional subsystems of cryogen distribution, transfer lines, warm gas management, and computer control interface were added. This paper describes the major plant subsystems, modifications, operational experiences and performance

  5. Expert system for surveillance and diagnosis of breach fuel elements

    Science.gov (United States)

    Gross, Kenny C.

    1989-01-01

    An apparatus and method are disclosed for surveillance and diagnosis of breached fuel elements in a nuclear reactor. A delayed neutron monitoring system provides output signals indicating the delayed neutron activity and age and the equivalent recoil areas of a breached fuel element. Sensors are used to provide outputs indicating the status of each component of the delayed neutron monitoring system. Detectors also generate output signals indicating the reactor power level and the primary coolant flow rate of the reactor. The outputs from the detectors and sensors are interfaced with an artificial intelligence-based knowledge system which implements predetermined logic and generates output signals indicating the operability of the reactor.

  6. Expert system for surveillance and diagnosis of breach fuel elements

    International Nuclear Information System (INIS)

    Gross, K.C.

    1989-01-01

    An apparatus and method are disclosed for surveillance and diagnosis of breached fuel elements in a nuclear reactor. A delayed neutron monitoring system provides output signals indicating the delayed neutron activity and age and the equivalent recoil areas of a breached fuel element. Sensors are used to provide outputs indicating the status of each component of the delayed neutron monitoring system. Detectors also generate output signals indicating the reactor power level and the primary coolant flow rate of the reactor. The outputs from the detectors and sensors are interfaced with an artificial intelligence-based knowledge system which implements predetermined logic and generates output signals indicating the operability of the reactor

  7. IEEE standard for design qualification of safety systems equipment used in nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    This standard is written to serve as a general standard for qualification of all types of safety systems equipment, mechanical and instrumentation as well as electrical. It also establishes principles and procedures to be followed in preparing specific safety systems equipment standards. Guidance for qualifying specific safety systems equipment may be found in various specific equipment qualification standards that are now available or are being prepared. It is required that safety systems equipment in nuclear power generating stations meet or exceed its performance requirements throughout its installed life. This is accomplished by a disciplined program of design qualification and quality assurance of design, production, installation, maintenance and surveillance. This standard is for the design qualification section of the program only. Design qualification is intended to demonstrate the capability of the equipment design to perform its safety function(s) over the expected range of normal, abnormal, design basis event, post design basis event, and in-service test conditions. Inherent to design qualification is the requirement for demonstration, within limitations afforded by established technical state-of-the-art, that in-service aging throughout the qualified life established for the equipment will not degrade safety systems equipment from its original design condition to the point where it cannot perform its required safety function(s), upon demand. The above requirement reflects the primary role of design qualification to provide reasonable assurance that design- and age-related common failure modes will not occur during performance of safety function(s) under postulated service conditions

  8. Towards One Health disease surveillance: The Southern African Centre for Infectious Disease Surveillance approach

    Directory of Open Access Journals (Sweden)

    Esron D. Karimuribo

    2012-06-01

    Full Text Available Africa has the highest burden of infectious diseases in the world and yet the least capacity for its risk management. It has therefore become increasingly important to search for ‘fit-for- purpose’ approaches to infectious disease surveillance and thereby targeted disease control. The fact that the majority of human infectious diseases are originally of animal origin means we have to consider One Health (OH approaches which require inter-sectoral collaboration for custom-made infectious disease surveillance in the endemic settings of Africa. A baseline survey was conducted to assess the current status and performance of human and animal health surveillance systems and subsequently a strategy towards OH surveillance system was developed. The strategy focused on assessing the combination of participatory epidemiological approaches and the deployment of mobile technologies to enhance the effectiveness of disease alerts and surveillance at the point of occurrence, which often lies in remote areas. We selected three study sites, namely the Ngorongoro, Kagera River basin and Zambezi River basin ecosystems. We have piloted and introduced the next-generation Android mobile phones running the EpiCollect application developed by Imperial College to aid geo-spatial and clinical data capture and transmission of this data from the field to the remote Information Technology (IT servers at the research hubs for storage, analysis, feedback and reporting. We expect that the combination of participatory epidemiology and technology will significantly improve OH disease surveillance in southern Africa.

  9. Towards one health disease surveillance: the Southern African Centre for Infectious Disease Surveillance approach.

    Science.gov (United States)

    Karimuribo, Esron D; Sayalel, Kuya; Beda, Eric; Short, Nick; Wambura, Philemon; Mboera, Leonard G; Kusiluka, Lughano J M; Rweyemamu, Mark M

    2012-06-20

    Africa has the highest burden of infectious diseases in the world and yet the least capacity for its risk management. It has therefore become increasingly important to search for 'fit-for- purpose' approaches to infectious disease surveillance and thereby targeted disease control. The fact that the majority of human infectious diseases are originally of animal origin means we have to consider One Health (OH) approaches which require inter-sectoral collaboration for custom-made infectious disease surveillance in the endemic settings of Africa. A baseline survey was conducted to assess the current status and performance of human and animal health surveillance systems and subsequently a strategy towards OH surveillance system was developed. The strategy focused on assessing the combination of participatory epidemiological approaches and the deployment of mobile technologies to enhance the effectiveness of disease alerts and surveillance at the point of occurrence, which often lies in remote areas. We selected three study sites, namely the Ngorongoro, Kagera River basin and Zambezi River basin ecosystems. We have piloted and introduced the next-generation Android mobile phones running the EpiCollect application developed by Imperial College to aid geo-spatial and clinical data capture and transmission of this data from the field to the remote Information Technology (IT) servers at the research hubs for storage, analysis, feedback and reporting. We expect that the combination of participatory epidemiology and technology will significantly improve OH disease surveillance in southern Africa.

  10. Video Surveillance: Privacy Issues and Legal Compliance

    DEFF Research Database (Denmark)

    Mahmood Rajpoot, Qasim; Jensen, Christian D.

    2015-01-01

    Pervasive usage of video surveillance is rapidly increasing in developed countries. Continuous security threats to public safety demand use of such systems. Contemporary video surveillance systems offer advanced functionalities which threaten the privacy of those recorded in the video. There is a...

  11. On Chinese National Continuous Operating Reference Station System of GNSS

    Directory of Open Access Journals (Sweden)

    CHEN Junyong

    2007-11-01

    Full Text Available Objective: Global navigation satellite system (GNSS Continuous Operating Reference Station (CORS System can maintain a accurate, 3D, geocentric and dynamic reference coordinate frame in the corresponding area, can provide positioning and navigation service. It can also serve for the meteorology, geodynamics, earthquake monitoring and Location Based services (LBS etc in the same area. Until now, our country can’t provide a facing National CORS System serving for every profession and trade, and the national sharing platform of CORS System resources has not been established. So this paper discusses some valuable insight how to construct the National CORS System in China. Method: Constructing goal、Service object、CORS distribution、CORS geographic、geology and communication environment and other factors, are major considerations for the Constructing the National CORS System. Moreover, constructing GNSS CORS is more specific, mainly from four aspects, namely site-selection、civil construction、security measures and equipment-selection for consideration. Outcome: The project of the Constructing Global navigation satellite system (GNSS Continuous Operating Reference Station (CORS System in china is put forward, and is discussed from goal、principle、project and other for construction. Some meaning thought how to construct the National CORS System is submitted Conclusion: The Global navigation satellite system (GNSS Continuous Operating Reference Station (CORS System in china is the lack of a unified planning and design in the national level. So far, the national CORS system serving all walks of life has not been provided, and the national sharing platform of CORS System resources has not been established The primary mission of the Global navigation satellite system (GNSS Continuous Operating Reference Station (CORS System in china is as follows: using data set of GNSS and receiving, transport, process, integration, transmit information and

  12. [A review on the advancement of internet-based public health surveillance program].

    Science.gov (United States)

    Zhao, Y Q; Ma, W J

    2017-02-10

    Internet data is introduced into public health arena under the features of fast updating and tremendous volume. Mining and analyzing internet data, researchers can model the internet-based surveillance system to assess the distribution of health-related events. There are two main types of internet-based surveillance systems, i.e. active and passive, which are distinguished by the sources of information. Through passive surveillance system, information is collected from search engine and social media while the active system gathers information through provision of the volunteers. Except for serving as a real-time and convenient complementary approach to traditional disease, food safety and adverse drug reaction surveillance program, Internet-based surveillance system can also play a role in health-related behavior surveillance and policy evaluation. Although several techniques have been applied to filter information, the accuracy of internet-based surveillance system is still bothered by the false positive information. In this article, we have summarized the development and application of internet-based surveillance system in public health to provide reference for a better surveillance program in China.

  13. Daya Bay Nuclear Power Station operation and management indicators system

    International Nuclear Information System (INIS)

    Fang Chunfa

    2000-01-01

    Ever since the commercial operation of Daya Bay Nuclear Power Station (GNPS), dynamic objective management concept that features modern enterprises has been adopted by the station to manage all operational activities with the guidance of business plan. And some quantitative indicators have been employed in order to measure effectively the progress status of these operational activities. After several years' evolvement, a hierarchical and standard performance indicators system has been developed and is playing an active part in the plant's efforts towards top quartile of world nuclear power industry. Structured hierarchically with higher levels resolving into lower levels and lower levels committing to higher levels, the indicator system represents the corporate vision, WANO (World Association of Nuclear Operators) performance indicators, plant integrated indicators and departmental key indicators, covering such areas as safety, production, environment, human resource and cost control. The indicator system not only reflects performance-centered management concept, but also shows the controllability of the whole operational process of the station. Indicators of a certain level serve as both early warnings to superior indicators (lagging indicators in this case) and effects to inferior indicators (leading indicators in this case). The dynamic status of these indicators, numbered more than 230, will eventually be fed back to the business plan and realized through daily work of every branch, and even every member of the workforce. With the indicator system as a quantitative management tool, and an effective tracking system, GNPS has achieved great success in self-assessment, objective definition, improvement follow up, resource re-allocation, and management-staff communication. Periodic plant performance assessment is performed through spider chart and other pictorial diagrams. Indicators are displayed at the plant entrance, offices, Main Control Room and SIS network

  14. The design and evaluation of an antimicrobial resistance surveillance system for neonatal intensive care units in Iran.

    Science.gov (United States)

    Rezaei-Hachesu, Peyman; Samad-Soltani, Taha; Yaghoubi, Sajad; GhaziSaeedi, Marjan; Mirnia, Kayvan; Masoumi-Asl, Hossein; Safdari, Reza

    2018-07-01

    Neonatal intensive care units (NICUs) have complex patients in terms of their diagnoses and required treatments. Antimicrobial treatment is a common therapy for patients in NICUs. To solve problems pertaining to empirical therapy, antimicrobial stewardship programs have recently been introduced. Despite the success of these programs in terms of data collection, there is still inefficiency in terms of analyzing and reporting the data. Thus, to successfully implement these stewardship programs, the design of antimicrobial resistance (AMR) surveillance systems is recommended as a first step. As a result, this study aimed to design an AMR surveillance system for use in the NICUs in northwestern Iranian hospitals to cover these information gaps. The recommended system is compatible with the World Health Organization (WHO) guidelines. The business intelligence (BI) requirements were extracted in an interview with a product owner (PO) using a valid and reliable checklist. Following this, an AMR surveillance system was designed and evaluated in relation to user experiences via a user experience questionnaire (UEQ). Finally, an association analysis was performed on the database, and the results were reported by identifying the important multidrug resistances in the database. A customized software development methodology was proposed. The three major modules of the AMR surveillance are the data registry, dashboard, and decision support modules. The data registry module was implemented based on a three-tier architecture, and the Clinical Decision Support System (CDSS) and dashboard modules were designed based on the BI requirements of the Scrum product owner (PO). The mean values of UEQ measures were in a good range. This measures showed the suitable usability of the AMR surveillance system. Applying efficient software development methodologies allows for the systems' compatibility with users' opinions and requirements. In addition, the construction of interdisciplinary

  15. Parallel Computational Intelligence-Based Multi-Camera Surveillance System

    Directory of Open Access Journals (Sweden)

    Sergio Orts-Escolano

    2014-04-01

    Full Text Available In this work, we present a multi-camera surveillance system based on the use of self-organizing neural networks to represent events on video. The system processes several tasks in parallel using GPUs (graphic processor units. It addresses multiple vision tasks at various levels, such as segmentation, representation or characterization, analysis and monitoring of the movement. These features allow the construction of a robust representation of the environment and interpret the behavior of mobile agents in the scene. It is also necessary to integrate the vision module into a global system that operates in a complex environment by receiving images from multiple acquisition devices at video frequency. Offering relevant information to higher level systems, monitoring and making decisions in real time, it must accomplish a set of requirements, such as: time constraints, high availability, robustness, high processing speed and re-configurability. We have built a system able to represent and analyze the motion in video acquired by a multi-camera network and to process multi-source data in parallel on a multi-GPU architecture.

  16. Assessing the population coverage of a health demographic surveillance system using satellite imagery and crowd-sourcing.

    Directory of Open Access Journals (Sweden)

    Aurelio Di Pasquale

    Full Text Available Remotely sensed data can serve as an independent source of information about the location of residential structures in areas under demographic and health surveillance. We report on results obtained combining satellite imagery, imported from Bing, with location data routinely collected using the built-in GPS sensors of tablet computers, to assess completeness of population coverage in a Health and Demographic Surveillance System in Malawi. The Majete Malaria Project Health and Demographic Surveillance System, in Malawi, started in 2014 to support a project with the aim of studying the reduction of malaria using an integrated control approach by rolling out insecticide treated nets and improved case management supplemented with house improvement and larval source management. In order to support the monitoring of the trial a Health and Demographic Surveillance System was established in the area that surrounds the Majete Wildlife Reserve (1600 km2, using the OpenHDS data system. We compared house locations obtained using GPS recordings on mobile devices during the demographic surveillance census round with those acquired from satellite imagery. Volunteers were recruited through the crowdcrafting.org platform to identify building structures on the images, which enabled the compilation of a database with coordinates of potential residences. For every building identified on these satellite images by the volunteers (11,046 buildings identified of which 3424 (ca. 30% were part of the censused area, we calculated the distance to the nearest house enumerated on the ground by fieldworkers during the census round of the HDSS. A random sample of buildings (85 structures identified on satellite images without a nearby location enrolled in the census were visited by a fieldworker to determine how many were missed during the baseline census survey, if any were missed. The findings from this ground-truthing effort suggest that a high population coverage was

  17. Assessment of the infectious diseases surveillance system of the Republic of Armenia: an example of surveillance in the Republics of the former Soviet Union

    Directory of Open Access Journals (Sweden)

    Mac Kenzie William R

    2002-02-01

    Full Text Available Abstract Background Before 1991, the infectious diseases surveillance systems (IDSS of the former Soviet Union (FSU were centrally planned in Moscow. The dissolution of the FSU resulted in economic stresses on public health infrastructure. At the request of seven FSU Ministries of Health, we performed assessments of the IDSS designed to guide reform. The assessment of the Armenian infectious diseases surveillance system (AIDSS is presented here as a prototype. Discussion We performed qualitative assessments using the Centers for Disease Control and Prevention (CDC guidelines for evaluating surveillance systems. Until 1996, the AIDSS collected aggregate and case-based data on 64 infectious diseases. It collected information on diseases of low pathogenicity (e.g., pediculosis and those with no public health intervention (e.g., infectious mononucleosis. The specificity was poor because of the lack of case definitions. Most cases were investigated using a lengthy, non-disease-specific case-report form Armenian public health officials analyzed data descriptively and reported data upward from the local to national level, with little feedback. Information was not shared across vertical programs. Reform should focus on enhancing usefulness, efficiency, and effectiveness by reducing the quantity of data collected and revising reporting procedures and information types; improving the quality, analyses, and use of data at different levels; reducing system operations costs; and improving communications to reporting sources. These recommendations are generalizable to other FSU republics. Summary The AIDSS was complex and sensitive, yet costly and inefficient. The flexibility, representativeness, and timeliness were good because of a comprehensive health-care system and compulsory reporting. Some data were questionable and some had no utility.

  18. Distributed data processing for public health surveillance

    Directory of Open Access Journals (Sweden)

    Yih Katherine

    2006-09-01

    Full Text Available Abstract Background Many systems for routine public health surveillance rely on centralized collection of potentially identifiable, individual, identifiable personal health information (PHI records. Although individual, identifiable patient records are essential for conditions for which there is mandated reporting, such as tuberculosis or sexually transmitted diseases, they are not routinely required for effective syndromic surveillance. Public concern about the routine collection of large quantities of PHI to support non-traditional public health functions may make alternative surveillance methods that do not rely on centralized identifiable PHI databases increasingly desirable. Methods The National Bioterrorism Syndromic Surveillance Demonstration Program (NDP is an example of one alternative model. All PHI in this system is initially processed within the secured infrastructure of the health care provider that collects and holds the data, using uniform software distributed and supported by the NDP. Only highly aggregated count data is transferred to the datacenter for statistical processing and display. Results Detailed, patient level information is readily available to the health care provider to elucidate signals observed in the aggregated data, or for ad hoc queries. We briefly describe the benefits and disadvantages associated with this distributed processing model for routine automated syndromic surveillance. Conclusion For well-defined surveillance requirements, the model can be successfully deployed with very low risk of inadvertent disclosure of PHI – a feature that may make participation in surveillance systems more feasible for organizations and more appealing to the individuals whose PHI they hold. It is possible to design and implement distributed systems to support non-routine public health needs if required.

  19. Internet and Surveillance

    DEFF Research Database (Denmark)

    The Internet has been transformed in the past years from a system primarily oriented on information provision into a medium for communication and community-building. The notion of “Web 2.0”, social software, and social networking sites such as Facebook, Twitter and MySpace have emerged in this co......The Internet has been transformed in the past years from a system primarily oriented on information provision into a medium for communication and community-building. The notion of “Web 2.0”, social software, and social networking sites such as Facebook, Twitter and MySpace have emerged...... institutions have a growing interest in accessing this personal data. Here, contributors explore this changing landscape by addressing topics such as commercial data collection by advertising, consumer sites and interactive media; self-disclosure in the social web; surveillance of file-sharers; privacy...... in the age of the internet; civil watch-surveillance on social networking sites; and networked interactive surveillance in transnational space. This book is a result of a research action launched by the intergovernmental network COST (European Cooperation in Science and Technology)....

  20. An opportunity analysis system for space surveillance experiments with the MSX

    Science.gov (United States)

    Sridharan, Ramaswamy; Duff, Gary; Hayes, Tony; Wiseman, Andy

    1994-01-01

    The Mid-Course Space Experiment consists of a set of payloads on a satellite being designed and built under the sponsorship of Ballistic Missile Defense Office. The MSX satellite will conduct a series of measurements of phenomenology of backgrounds, missile targets, plumes and resident space objects (RSO's); and will engage in functional demonstrations in support of detection, acquisition and tracking for ballistic missile defense and space-based space surveillance missions. A complex satellite like the MSX has several constraints imposed on its operation by the sensors, the supporting instrumentation, power resources, data recording capability, communications and the environment in which all these operate. This paper describes the implementation of an opportunity and feasibility analysis system, developed at Lincoln Laboratory, Massachusetts Institute of Technology, specifically to support the experiments of the Principal Investigator for space-based surveillance.

  1. EUPOS - Satellite multifunctional system of reference stations in Central and Eastern Europe

    Science.gov (United States)

    Sledzinski, J.

    2003-04-01

    The European project EUPOS (European Position Determination System) of establishment of a system of multifunctional satellite reference stations in Central and Eastern Europe is described in the paper. Fifteen countries intend to participate in the project: Bulgaria, Croatia, Czech Republic, Estonia, Germany, Hungary, Latvia, Lithuania, Macedonia, Poland, Romania, Russia, Serbia, Slovak Republic and Slovenia. One common project will be prepared for all countries, however it will include the existing or developed infrastructure in particular countries. The experiences of establishing and operating of the German network SAPOS as well as experiences gained by other countries will be used. The European network of stations will be compatible with the system SAPOS and future European system Galileo. The network of reference stations will provide signal for both positioning of the geodetic control points and for land, air and marine navigation. Several levels of positioning accuracy will be delivered.

  2. A review of zoonotic disease surveillance supported by the Armed Forces Health Surveillance Center.

    Science.gov (United States)

    Burke, R L; Kronmann, K C; Daniels, C C; Meyers, M; Byarugaba, D K; Dueger, E; Klein, T A; Evans, B P; Vest, K G

    2012-05-01

    The Armed Forces Health Surveillance Center (AFHSC), Division of Global Emerging Infections Surveillance and Response System conducts disease surveillance through a global network of US Department of Defense research laboratories and partnerships with foreign ministries of agriculture, health and livestock development in over 90 countries worldwide. In 2010, AFHSC supported zoonosis survey efforts were organized into four main categories: (i) development of field assays for animal disease surveillance during deployments and in resource limited environments, (ii) determining zoonotic disease prevalence in high-contact species which may serve as important reservoirs of diseases and sources of transmission, (iii) surveillance in high-risk human populations which are more likely to become exposed and subsequently infected with zoonotic pathogens and (iv) surveillance at the human-animal interface examining zoonotic disease prevalence and transmission within and between human and animal populations. These efforts have aided in the detection, identification and quantification of the burden of zoonotic diseases such as anthrax, brucellosis, Crimean Congo haemorrhagic fever, dengue fever, Hantaan virus, influenza, Lassa fever, leptospirosis, melioidosis, Q fever, Rift Valley fever, sandfly fever Sicilian virus, sandfly fever Naples virus, tuberculosis and West Nile virus, which are of military and public health importance. Future zoonotic surveillance efforts will seek to develop local capacity for zoonotic surveillance focusing on high risk populations at the human-animal interface. © 2011 Blackwell Verlag GmbH.

  3. Use of unmanned aerial vehicle (UAV) for the detection and surveillance of marine oil spills in the Belgian part of the North Sea

    International Nuclear Information System (INIS)

    Donnay, E.

    2009-01-01

    This paper discussed the use of unmanned aerial vehicles (UAV) deployed by the Belgian Army in order to detect oil spills as well as for intelligence, reconnaissance and surveillance missions. The UAV are fitted with a dual sensor gyro-stabilized turret which combines a daylight camera and a thermal infrared camera. Live images of the sensors are transmitted in real time to control stations. All Belgian marine pollution surveillance platforms are coordinated by the Maritime Security Center of the Belgian Coast Guard. Satellite surveillance services provide real time information related to potential oil spills and other anomalies on the sea surface. Stand-by helicopters are also used for the rapid assessment of reported spills. The B-Hunter system is undetectable due to its small size and low noise signature, and can be used for the continuous monitoring of specific areas or for the tracking of suspect vessels. The system will also be used to monitor the progress of oil spill response operations as well as to provide information and guidance to response vessels. 6 refs., 2 figs

  4. Use of unmanned aerial vehicle (UAV) for the detection and surveillance of marine oil spills in the Belgian part of the North Sea

    Energy Technology Data Exchange (ETDEWEB)

    Donnay, E. [Federal Public Service Health, Food Chain Safety and Environment, Brussels (Belgium)

    2009-07-01

    This paper discussed the use of unmanned aerial vehicles (UAV) deployed by the Belgian Army in order to detect oil spills as well as for intelligence, reconnaissance and surveillance missions. The UAV are fitted with a dual sensor gyro-stabilized turret which combines a daylight camera and a thermal infrared camera. Live images of the sensors are transmitted in real time to control stations. All Belgian marine pollution surveillance platforms are coordinated by the Maritime Security Center of the Belgian Coast Guard. Satellite surveillance services provide real time information related to potential oil spills and other anomalies on the sea surface. Stand-by helicopters are also used for the rapid assessment of reported spills. The B-Hunter system is undetectable due to its small size and low noise signature, and can be used for the continuous monitoring of specific areas or for the tracking of suspect vessels. The system will also be used to monitor the progress of oil spill response operations as well as to provide information and guidance to response vessels. 6 refs., 2 figs.

  5. Validation of an electronic surveillance system for acute lung injury.

    Science.gov (United States)

    Herasevich, Vitaly; Yilmaz, Murat; Khan, Hasrat; Hubmayr, Rolf D; Gajic, Ognjen

    2009-06-01

    Early detection of acute lung injury (ALI) is essential for timely implementation of evidence-based therapies and enrollment into clinical trials. We aimed to determine the accuracy of computerized syndrome surveillance for detection of ALI in hospitalized patients and compare it with routine clinical assessment. Using a near-real time copy of the electronic medical records, we developed and validated a custom ALI electronic alert (ALI "sniffer") based on the European-American Consensus Conference Definition and compared its performance against provider-derived documentation. A total of 3,795 consecutive critically ill patients admitted to nine multidisciplinary intensive care units (ICUs) of a tertiary care teaching institution were included. ALI developed in 325 patients and was recognized by bedside clinicians in only 86 (26.5%). Under-recognition of ALI was associated with not implementing protective mechanical ventilation (median tidal volumes of 9.2 vs. 8.0 ml/kg predicted body weight, P sniffer" demonstrated excellent sensitivity of 96% (95% CI 94-98) and moderate specificity of 89% (95% CI 88-90) with a positive predictive value ranging from 24% (95% CI 13-40) in the heart-lung transplant ICU to 64% (95% CI 55-71) in the medical ICU. The computerized surveillance system accurately identifies critically ill patients who develop ALI syndrome. Since the lack of ALI recognition is a barrier to the timely implementation of best practices and enrollment into research studies, computerized syndrome surveillance could be a useful tool to enhance patient safety and clinical research.

  6. National Infectious Diseases Surveillance data of South Korea.

    Science.gov (United States)

    Park, Sunhee; Cho, Eunhee

    2014-01-01

    The Korea Centers for Disease Control and Prevention (KCDC) operate infectious disease surveillance systems to monitor national disease incidence. Since 1954, Korea has collected data on various infectious diseases in accordance with the Infectious Disease Control and Prevention Act. All physicians (including those working in Oriental medicine) who diagnose a patient with an infectious disease or conduct a postmortem examination of an infectious disease case are obliged to report the disease to the system. These reported data are incorporated into the database of the National Infectious Disease Surveillance System, which has been providing web-based real-time surveillance data on infectious diseases since 2001. In addition, the KCDC analyzes reported data and publishes the Infectious Disease Surveillance Yearbook annually.

  7. National laboratory-based surveillance system for antimicrobial resistance : a successful tool to support the control of antimicrobial resistance in the Netherlands

    NARCIS (Netherlands)

    Altorf-van der Kuil, Wieke; Schoffelen, Annelot F.; de Greeff, Sabine C; Thijsen, Steven Ft; Alblas, H Jeroen; Notermans, Daan W; Vlek, Anne Lm; van der Sande, Marianne Ab; Leenstra, Tjalling

    2017-01-01

    An important cornerstone in the control of antimicrobial resistance (AMR) is a well-designed quantitative system for the surveillance of spread and temporal trends in AMR. Since 2008, the Dutch national AMR surveillance system, based on routine data from medical microbiological laboratories (MMLs),

  8. National laboratory-based surveillance system for antimicrobial resistance: a successful tool to support the control of antimicrobial resistance in the Netherlands.

    NARCIS (Netherlands)

    Altorf-van der Kuil, Wieke; Schoffelen, Annelot F; de Greeff, Sabine C; Thijsen, Steven Ft; Alblas, H Jeroen; Notermans, Daan W; Vlek, Anne Lm; van der Sande, Marianne Ab; Leenstra, Tjalling

    2017-01-01

    An important cornerstone in the control of antimicrobial resistance (AMR) is a well-designed quantitative system for the surveillance of spread and temporal trends in AMR. Since 2008, the Dutch national AMR surveillance system, based on routine data from medical microbiological laboratories (MMLs),

  9. French experience in transient data collection and fatigue monitoring of PWR`s nuclear steam supply system; Experience francaise sur la comptabilisation des transitoires et la surveillance en fatigue des chaudieres REP

    Energy Technology Data Exchange (ETDEWEB)

    Sabaton, M.; Morilhat, P.; Savoldelli, D.; Genette, P.

    1995-10-01

    Electricite de France (EDF), the french national electricity company, is operating 54 standardized pressurizer water reactors. This about 500 reactor-years experience in nuclear stations operation and maintenance area has allowed EDF to develop its own strategy for monitoring of age-related degradations of NPP systems and components relevant for plant safety and reliability. After more than fifteen years of experience in regulatory transient data collection and seven years of successful fatigue monitoring prototypes experimentation, EDF decided to design a new system called SYSFAC (acronym for SYsteme de Surveillance en FAtigue de la Chaudiere) devoted to transient logging and thermal fatigue monitoring of the reactor coolant pressure boundary. The system is fully automatic and directly connected to the on-site data acquisition network without any complementary instrumentation. A functional transient detection module and a mechanical transient detection module are in charge of the general transient data collection. A fatigue monitoring module is aimed towards a precise surveillance of five specific zones particularly sensible to thermal fatigue. After the first step of preliminary studies, the industrial phase of the SYSFAC project is currently going on, with hardware and software tests and implementation. The first SYSFAC system will be delivered to the pilot power plant by the beginning of 1996. The extension to all EDF`s nuclear 900 MW is planned after one more year of feedback experience. (authors). 12 refs., 3 figs.

  10. Automated ultrasonic inspection system for nuclear power stations

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    The automated system of ultrasonic inspection which was used to conduct weld inspections of the complex primary system of the Borselle PWR station is described. It relies upon mechanically traversing purpose designed multi-crystal ultrasonic probes along the welds. A number of probes are switched sequentially to provide a continuous scan. A typical scan rate of 120 scan/sec is achieved by a multiplexer capable of switching transmitter and receiver individually. The system has wide applications in other industries. (U.K.)

  11. Space Station thermal storage/refrigeration system research and development

    Science.gov (United States)

    Dean, W. G.; Karu, Z. S.

    1993-01-01

    Space Station thermal loading conditions represent an order of magnitude increase over current and previous spacecraft such as Skylab, Apollo, Pegasus III, Lunar Rover Vehicle, and Lockheed TRIDENT missiles. Thermal storage units (TSU's) were successfully used on these as well as many applications for ground based solar energy storage applications. It is desirable to store thermal energy during peak loading conditions as an alternative to providing increased radiator surface area which adds to the weight of the system. Basically, TSU's store heat by melting a phase change material (PCM) such as a paraffin. The physical property data for the PCM's used in the design of these TSU's is well defined in the literature. Design techniques are generally well established for the TSU's. However, the Space Station provides a new challenge in the application of these data and techniques because of three factors: the large size of the TSU required, the integration of the TSU for the Space Station thermal management concept with its diverse opportunities for storage application, and the TSU's interface with a two-phase (liquid/vapor) thermal bus/central heat rejection system. The objective in the thermal storage research and development task was to design, fabricate, and test a demonstration unit. One test article was to be a passive thermal storage unit capable of storing frozen food at -20 F for a minimum of 90 days. A second unit was to be capable of storing frozen biological samples at -94 F, again for a minimum of 90 days. The articles developed were compatible with shuttle mission conditions, including safety and handling by astronauts. Further, storage rack concepts were presented so that these units can be integrated into Space Station logistics module storage racks. The extreme sensitivity of spacecraft radiator systems design-to-heat rejection temperature requirements is well known. A large radiator area penalty is incurred if low temperatures are accommodated via a

  12. Integrated Monitoring and Surveillance System demonstration project. Phase 2 accomplishments

    International Nuclear Information System (INIS)

    Aumeier, S.E.; Walters, B.G.; Singleterry, R.C.

    1997-01-01

    The paper presents the results of the Integrated Monitoring and Surveillance System (IMSS) demonstration project Phase 2 efforts. the rationale behind IMSS development is reviewed and progress in each of the 5 basic tasks is detailed. Significant results include further development of the data acquisition system and procurement of necessary hardware/software, options and associated costs for plutonium canning systems and gloveboxes, initiation of facility modifications, determination of possibly affected facility documentation, results from sensor system trade study, and preliminary storage configuration designs. Resources invested during Phase 1 and Phase 2 are summarized and budgetary requirements for completion of Phase 3 presented. The results show that the IMSS demonstration project team has met and in many cases exceeded the commitments made for Phase 2 deliverables

  13. Automated video surveillance: teaching an old dog new tricks

    Science.gov (United States)

    McLeod, Alastair

    1993-12-01

    The automated video surveillance market is booming with new players, new systems, new hardware and software, and an extended range of applications. This paper reviews available technology, and describes the features required for a good automated surveillance system. Both hardware and software are discussed. An overview of typical applications is also given. A shift towards PC-based hybrid systems, use of parallel processing, neural networks, and exploitation of modern telecomms are introduced, highlighting the evolution modern video surveillance systems.

  14. Digital dashboard design using multiple data streams for disease surveillance with influenza surveillance as an example.

    Science.gov (United States)

    Cheng, Calvin K Y; Ip, Dennis K M; Cowling, Benjamin J; Ho, Lai Ming; Leung, Gabriel M; Lau, Eric H Y

    2011-10-14

    Great strides have been made exploring and exploiting new and different sources of disease surveillance data and developing robust statistical methods for analyzing the collected data. However, there has been less research in the area of dissemination. Proper dissemination of surveillance data can facilitate the end user's taking of appropriate actions, thus maximizing the utility of effort taken from upstream of the surveillance-to-action loop. The aims of the study were to develop a generic framework for a digital dashboard incorporating features of efficient dashboard design and to demonstrate this framework by specific application to influenza surveillance in Hong Kong. Based on the merits of the national websites and principles of efficient dashboard design, we designed an automated influenza surveillance digital dashboard as a demonstration of efficient dissemination of surveillance data. We developed the system to synthesize and display multiple sources of influenza surveillance data streams in the dashboard. Different algorithms can be implemented in the dashboard for incorporating all surveillance data streams to describe the overall influenza activity. We designed and implemented an influenza surveillance dashboard that utilized self-explanatory figures to display multiple surveillance data streams in panels. Indicators for individual data streams as well as for overall influenza activity were summarized in the main page, which can be read at a glance. Data retrieval function was also incorporated to allow data sharing in standard format. The influenza surveillance dashboard serves as a template to illustrate the efficient synthesization and dissemination of multiple-source surveillance data, which may also be applied to other diseases. Surveillance data from multiple sources can be disseminated efficiently using a dashboard design that facilitates the translation of surveillance information to public health actions.

  15. Surveillance Analysis Computer System (SACS): Software requirements specification (SRS). Revision 2

    International Nuclear Information System (INIS)

    Glasscock, J.A.

    1995-01-01

    This document is the primary document establishing requirements for the Surveillance Analysis Computer System (SACS) database, an Impact Level 3Q system. SACS stores information on tank temperatures, surface levels, and interstitial liquid levels. This information is retrieved by the customer through a PC-based interface and is then available to a number of other software tools. The software requirements specification (SRS) describes the system requirements for the SACS Project, and follows the Standard Engineering Practices (WHC-CM-6-1), Software Practices (WHC-CM-3-10) and Quality Assurance (WHC-CM-4-2, QR 19.0) policies

  16. Groundwater surveillance plan for the Oak Ridge Reservation

    International Nuclear Information System (INIS)

    Forstrom, J.M.; Smith, E.D.; Winters, S.L.; McMaster, W.M.

    1994-07-01

    US Department of Energy (DOE) Order 5400.1 requires the preparation of environmental monitoring plans and implementation of environmental monitoring programs for all DOE facilities. The order identifies two distinct components of environmental monitoring, namely effluent monitoring and environmental surveillance. In general, effluent monitoring has the objectives of characterizing contaminants and demonstrating compliance with applicable standards and permit requirements, whereas environmental surveillance has the broader objective of monitoring the effects of DOE activities on on- and off-site environmental and natural resources. The purpose of this document is to support the Environmental Monitoring Plan for the Oak Ridge Reservation (ORR) by describing the groundwater component of the environmental surveillance program for the DOE facilities on the ORR. The distinctions between groundwater effluent monitoring and groundwater surveillance have been defined in the Martin Marietta Energy Systems, Inc., Groundwater Surveillance Strategy. As defined in the strategy, a groundwater surveillance program consists of two parts, plant perimeter surveillance and off-site water well surveillance. This document identifies the sampling locations, parameters, and monitoring frequencies for both of these activities on and around the ORR and describes the rationale for the program design. The program was developed to meet the objectives of DOE Order 5400.1 and related requirements in DOE Order 5400.5 and to conform with DOE guidance on environmental surveillance and the Energy Systems Groundwater Surveillance Strategy

  17. 77 FR 6000 - Airworthiness Directives; Aviation Communication & Surveillance Systems (ACSS) Traffic Alert and...

    Science.gov (United States)

    2012-02-07

    ... reduced surveillance aircraft tracks because of interference limiting. This AD requires upgrading software... FURTHER INFORMATION CONTACT: Abby Malmir, Aerospace Engineer, Systems and Equipment Branch, ANM-130L, FAA..., 2010) proposed to require upgrading software. The SNPRM proposed to require new updated software for...

  18. The Added-Value of Using Participatory Approaches to Assess the Acceptability of Surveillance Systems: The Case of Bovine Tuberculosis in Belgium

    Science.gov (United States)

    Calba, Clémentine; Goutard, Flavie Luce; Vanholme, Luc; Antoine-Moussiaux, Nicolas; Hendrikx, Pascal; Saegerman, Claude

    2016-01-01

    Context and Objective Bovine tuberculosis (bTB) surveillance in Belgium is essential to maintain the officially free status and to preserve animal and public health. An evaluation of the system is thus needed to ascertain the surveillance provides a precise description of the current situation in the country. The evaluation should assess stakeholders’ perceptions and expectations about the system due to the fact that the acceptability has an influence on the levels of sensitivity and timeliness of the surveillance system. The objective of the study was to assess the acceptability of the bTB surveillance in Belgium, using participatory tools and the OASIS flash tool (‘analysis tool for surveillance systems’). Methods For the participatory process, focus group discussions and individual interviews were implemented with representatives involved with the system, both from cattle and wildlife part of the surveillance. Three main tools were used: (i) relational diagrams associated with smileys, (ii) flow diagrams associated with proportional piling, and (iii) impact diagrams associated with proportional piling. A total of six criteria were assessed, among which five were scored on a scale from -1 to +1. For the OASIS flash tool, one full day meeting with representatives from stakeholders involved with the surveillance was organised. A total of 19 criteria linked to acceptability were scored on a scale from 0 to 3. Results and Conclusion Both methods highlighted a medium acceptability of the bTB surveillance. The main elements having a negative influence were the consequences of official notification of a bTB suspect case in a farm, the low remuneration paid to private veterinarians for execution of intradermal tuberculin tests and the practical difficulties about the containment of the animals. Based on the two evaluation processes, relevant recommendations to improve the surveillance were made. Based on the comparison between the two evaluation processes, the

  19. SCHISTOSOMIASIS: GEOSPATIAL SURVEILLANCE AND RESPONSE SYSTEMS IN SOUTHEAST ASIA

    Directory of Open Access Journals (Sweden)

    J. Malone

    2016-10-01

    Full Text Available Geographic information system (GIS and remote sensing (RS from Earth-observing satellites offer opportunities for rapid assessment of areas endemic for vector-borne diseases including estimates of populations at risk and guidance to intervention strategies. This presentation deals with GIS and RS applications for the control of schistosomiasis in China and the Philippines. It includes large-scale risk mapping including identification of suitable habitats for Oncomelania hupensis, the intermediate host snail of Schistosoma japonicum. Predictions of infection risk are discussed with reference to ecological transformations and the potential impact of climate change and the potential for long-term temperature increases in the North as well as the impact on rivers, lakes and water resource developments. Potential integration of geospatial mapping and modeling in schistosomiasis surveillance and response systems in Asia within Global Earth Observation System of Systems (GEOSS guidelines in the health societal benefit area is discussed.

  20. Privacy information management for video surveillance

    Science.gov (United States)

    Luo, Ying; Cheung, Sen-ching S.

    2013-05-01

    The widespread deployment of surveillance cameras has raised serious privacy concerns. Many privacy-enhancing schemes have been proposed to automatically redact images of trusted individuals in the surveillance video. To identify these individuals for protection, the most reliable approach is to use biometric signals such as iris patterns as they are immutable and highly discriminative. In this paper, we propose a privacy data management system to be used in a privacy-aware video surveillance system. The privacy status of a subject is anonymously determined based on her iris pattern. For a trusted subject, the surveillance video is redacted and the original imagery is considered to be the privacy information. Our proposed system allows a subject to access her privacy information via the same biometric signal for privacy status determination. Two secure protocols, one for privacy information encryption and the other for privacy information retrieval are proposed. Error control coding is used to cope with the variability in iris patterns and efficient implementation is achieved using surrogate data records. Experimental results on a public iris biometric database demonstrate the validity of our framework.

  1. Support systems for optics in the experiment stations at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Barraza, J.; Shu, D.; Kuzay, T.M.

    1994-01-01

    Support systems have been designed for optics in the experiment stations of the Advanced Photon Source at Argonne National Laboratory. These systems utilize modular precision positioning slides and stages arranged in 3-point kinematic mount fashion for optimum mechanical stability. Through the use of novel configurations, these systems can achieve large linear motions, six degree-of-freedom motion, and large load capacities without sacrificing valuable experimental station space. This paper will discuss the designs and specifications of the positioning systems developed

  2. Geo-enviromental monitoring system of the oil storages on petrol stations

    Directory of Open Access Journals (Sweden)

    Shimenkova Anastasiya Anatol'evna

    2014-03-01

    Full Text Available In large cities, fuel consumption is growing rapidly, and therefore the number of filling stations. And they are a source of anthropogenic impact on the environment and represent current scientific and practical task, because recently no research was conducted into the optimization of monitoring systems in the construction of gas station storage tanks, and no activity on replacing the obsolete design with new storage tanks. In this regard, much attention should be paid to the creation of geo-environmental systems integrated assessment of the environment, as well as modeling and forecasting various negative situations. In the modern world, the creation of such systems is possible with the help of modern computer tools such as geographic information systems.

  3. Space station environmental control and life support systems test bed program - an overview

    Science.gov (United States)

    Behrend, Albert F.

    As the National Aeronautics and Space Administration (NASA) begins to intensify activities for development of the Space Station, decisions must be made concerning the technical state of the art that will be baselined for the initial Space Station system. These decisions are important because significant potential exists for enhancing system performance and for reducing life-cycle costs. However, intelligent decisions cannot be made without an adequate assessment of new and ready technologies, i.e., technologies which are sufficiently mature to allow predevelopment demonstrations to prove their application feasibility and to quantify the risk associated with their development. Therefore, the NASA has implemented a technology development program which includes the establishment of generic test bed capabilities in which these new technologies and approaches can be tested at the prototype level. One major Space Station subsystem discipline in which this program has been implemented is the environmental control and life support system (ECLSS). Previous manned space programs such as Gemini, Apollo, and Space Shuttle have relied heavily on consumables to provide environmental control and life support services. However, with the advent of a long-duration Space Station, consumables must be reduced within technological limits to minimize Space Station resupply penalties and operational costs. The use of advanced environmental control and life support approaches involving regenerative processes offers the best solution for significant consumables reduction while also providing system evolutionary growth capability. Consequently, the demonstration of these "new technologies" as viable options for inclusion in the baseline that will be available to support a Space Station initial operational capability in the early 1990's becomes of paramount importance. The mechanism by which the maturity of these new regenerative life support technologies will be demonstrated is the Space

  4. European Surveillance System on Contact Allergies (ESSCA)

    DEFF Research Database (Denmark)

    Uter, W; Amario-Hita, J C; Balato, A

    2017-01-01

    BACKGROUND: Contact allergy is a common condition and can severely interfere with daily life or professional activities. Due to changes in exposures, such as introduction of new substances, new products or formulations and regulatory intervention, the spectrum of contact sensitization changes....... OBJECTIVE: To evaluate the current spectrum of contact allergy to allergens present in the European baseline series (EBS) across Europe. METHODS: Retrospective analysis of data collected by the European Surveillance System on Contact Allergies (ESSCA, www.essca-dc.org) in consecutively patch-tested patients......, 2013/14, in 46 departments in 12 European countries. RESULTS: Altogether, 31 689 patients were included in the analysis. Compared to a similar analysis in 2004, the prevalence of contact allergy to methylisothiazolinone went up to around 20% in several departments. In comparison, contact allergy...

  5. Space Station Freedom power - A reliability, availability, and maintainability assessment of the proposed Space Station Freedom electric power system

    Science.gov (United States)

    Turnquist, S. R.; Twombly, M.; Hoffman, D.

    1989-01-01

    A preliminary reliability, availability, and maintainability (RAM) analysis of the proposed Space Station Freedom electric power system (EPS) was performed using the unit reliability, availability, and maintainability (UNIRAM) analysis methodology. Orbital replacement units (ORUs) having the most significant impact on EPS availability measures were identified. Also, the sensitivity of the EPS to variations in ORU RAM data was evaluated for each ORU. Estimates were made of average EPS power output levels and availability of power to the core area of the space station. The results of assessments of the availability of EPS power and power to load distribution points in the space stations are given. Some highlights of continuing studies being performed to understand EPS availability considerations are presented.

  6. 47 CFR 95.139 - Adding a small base station or a small control station.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Adding a small base station or a small control... base station or a small control station. (a) Except for a GMRS system licensed to a non-individual, one or more small base stations or a small control station may be added to a GMRS system at any point...

  7. NASA Systems Autonomy Demonstration Project - Development of Space Station automation technology

    Science.gov (United States)

    Bull, John S.; Brown, Richard; Friedland, Peter; Wong, Carla M.; Bates, William

    1987-01-01

    A 1984 Congressional expansion of the 1958 National Aeronautics and Space Act mandated that NASA conduct programs, as part of the Space Station program, which will yield the U.S. material benefits, particularly in the areas of advanced automation and robotics systems. Demonstration programs are scheduled for automated systems such as the thermal control, expert system coordination of Station subsystems, and automation of multiple subsystems. The programs focus the R&D efforts and provide a gateway for transfer of technology to industry. The NASA Office of Aeronautics and Space Technology is responsible for directing, funding and evaluating the Systems Autonomy Demonstration Project, which will include simulated interactions between novice personnel and astronauts and several automated, expert subsystems to explore the effectiveness of the man-machine interface being developed. Features and progress on the TEXSYS prototype thermal control system expert system are outlined.

  8. Vers un modèle de surveillance intégrée des maladies exotiques abortives chez les bovins en France métropolitaine : évaluation de la surveillance évènementielle et exploration d’outils complémentaires de surveillance syndromique

    OpenAIRE

    Bronner , Anne

    2015-01-01

    The surveillance system for exotic abortive diseases in French cattle (i.e. abortive diseases that are not currently found in France), such as brucellosis, is a typical example of a surveillance system that is in need of improvement. This type of surveillance only actually exists for brucellosis. Clinical surveillance is the cornerstone of brucellosis surveillance and consists in the mandatory notification of each bovine abortion. However, while no quantitatively assessments have been made, i...

  9. Insights From Flutracking: Thirteen Tips to Growing a Web-Based Participatory Surveillance System.

    Science.gov (United States)

    Dalton, Craig; Carlson, Sandra; Butler, Michelle; Cassano, Daniel; Clarke, Stephen; Fejsa, John; Durrheim, David

    2017-08-17

    Flutracking is a weekly Web-based survey of influenza-like illness (ILI) in Australia that has grown from 400 participants in 2006 to over 26,000 participants every week in 2016. Flutracking monitors both the transmission and severity of ILI across Australia by documenting symptoms (cough, fever, and sore throat), time off work or normal duties, influenza vaccination status, laboratory testing for influenza, and health seeking behavior. Recruitment of Flutrackers commenced via health department and other organizational email systems, and then gradually incorporated social media promotion and invitations from existing Flutrackers to friends to enhance participation. Invitations from existing participants typically contribute to over 1000 new participants each year. The Flutracking survey link was emailed every Monday morning in winter and took less than 10 seconds to complete. To reduce the burden on respondents, we collected only a minimal amount of demographic and weekly data. Additionally, to optimize users' experiences, we maintained a strong focus on "obvious design" and repeated usability testing of naïve and current participants of the survey. In this paper, we share these and other insights on recruitment methods and user experience principles that have enabled Flutracking to become one of the largest online participatory surveillance systems in the world. There is still much that could be enhanced in Flutracking; however, we believe these principles could benefit others developing similar online surveillance systems. ©Craig Dalton, Sandra Carlson, Michelle Butler, Daniel Cassano, Stephen Clarke, John Fejsa, David Durrheim. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 17.08.2017.

  10. Health & Demographic Surveillance System profile: the Muzaffarpur-TMRC Health and Demographic Surveillance System.

    Science.gov (United States)

    Malaviya, Paritosh; Picado, Albert; Hasker, Epco; Ostyn, Bart; Kansal, Sangeeta; Singh, Rudra Pratap; Shankar, Ravi; Boelaert, Marleen; Sundar, Shyam

    2014-10-01

    The Muzaffarpur-TMRC Health and Demographic Surveillance System (HDSS), established in 2007, was developed as an enlargement of the scope of a research collaboration on the project Visceral Leishmaniasis in Bihar, which had been ongoing since 2005. The HDSS is located in a visceral leishmaniasis (VL)-endemic area in the Muzaffarpur district of Bihar state in India. It is the only HDSS conducting research on VL, which is a vector-borne infectious disease transmitted by female phlebotomine sandflies and is fatal if left untreated. Currently the HDSS serves a population of over 105,000 in 66 villages. The HDSS collects data on vital events including pregnancies, births, deaths, migration and marriages, as well as other socio-economic indicators, at regular intervals. Incident VL cases are identified. The HDSS team is experienced in conducting both qualitative and quantitative studies, sample collection and rapid diagnostic tests in the field. In each village, volunteers connect the HDSS team with the community members. The Muzaffarpur-TMRC HDSS provides opportunities for studies on VL and other neglected tropical diseases (NTDs) and their interaction with demographic events such as migration. Queries related to research collaborations and data sharing can be sent to Dr Shyam Sundar at [drshyamsundar@hotmail.com]. © The Author 2014; all rights reserved. Published by Oxford University Press on behalf of the International Epidemiological Association.

  11. Monitoring the introduction of pneumococcal conjugate vaccines into West Africa: design and implementation of a population-based surveillance system.

    Directory of Open Access Journals (Sweden)

    Grant A Mackenzie

    2012-01-01

    Full Text Available Routine use of pneumococcal conjugate vaccines (PCVs in developing countries is expected to lead to a significant reduction in childhood deaths. However, PCVs have been associated with replacement disease with non-vaccine serotypes. We established a population-based surveillance system to document the direct and indirect impact of PCVs on the incidence of invasive pneumococcal disease (IPD and radiological pneumonia in those aged 2 months and older in The Gambia, and to monitor changes in serotype-specific IPD. Here we describe how this surveillance system was set up and is being operated as a partnership between the Medical Research Council Unit and the Gambian Government. This surveillance system is expected to provide crucial information for immunisation policy and serves as a potential model for those introducing routine PCV vaccination in diverse settings.

  12. National laboratory-based surveillance system for antimicrobial resistance: a successful tool to support the control of antimicrobial resistance in the Netherlands.

    Science.gov (United States)

    Altorf-van der Kuil, Wieke; Schoffelen, Annelot F; de Greeff, Sabine C; Thijsen, Steven Ft; Alblas, H Jeroen; Notermans, Daan W; Vlek, Anne Lm; van der Sande, Marianne Ab; Leenstra, Tjalling

    2017-11-01

    An important cornerstone in the control of antimicrobial resistance (AMR) is a well-designed quantitative system for the surveillance of spread and temporal trends in AMR. Since 2008, the Dutch national AMR surveillance system, based on routine data from medical microbiological laboratories (MMLs), has developed into a successful tool to support the control of AMR in the Netherlands. It provides background information for policy making in public health and healthcare services, supports development of empirical antibiotic therapy guidelines and facilitates in-depth research. In addition, participation of the MMLs in the national AMR surveillance network has contributed to sharing of knowledge and quality improvement. A future improvement will be the implementation of a new semantic standard together with standardised data transfer, which will reduce errors in data handling and enable a more real-time surveillance. Furthermore, the scientific impact and the possibility of detecting outbreaks may be amplified by merging the AMR surveillance database with databases from selected pathogen-based surveillance programmes containing patient data and genotypic typing data.

  13. Final report : mobile surveillance and wireless communication systems field operational test. Volume 2, FOT objectives, organization, system design, results, conclusions, and recommendations

    Science.gov (United States)

    1999-03-01

    The Mobile Surveillance and Wireless Communication Systems Field Operational Test (FOT) evaluated the performance of wireless traffic detection and communications systems in areas where permanent detectors, electrical power, and landline communicatio...

  14. Automated graphic image generation system for effective representation of infectious disease surveillance data.

    Science.gov (United States)

    Inoue, Masashi; Hasegawa, Shinsaku; Suyama, Akihiko; Meshitsuka, Shunsuke

    2003-11-01

    Infectious disease surveillance schemes have been established to detect infectious disease outbreak in the early stages, to identify the causative viral strains, and to rapidly assess related morbidity and mortality. To make a scheme function well, two things are required. Firstly, it must have sufficient sensitivity and be timely to guarantee as short a delay as possible from collection to redistribution of information. Secondly, it must provide a good representation of the results of the surveillance. To do this, we have developed a database system that can redistribute the information via the Internet. The feature of this system is to automatically generate the graphic images based on the numerical data stored in the database by using Hypertext Preprocessor (PHP) script and Graphics Drawing (GD) library. It dynamically displays the information as a map or bar chart as well as a numerical impression according to the real time demand of the users. This system will be a useful tool for medical personnel and researchers working on infectious disease problems and will save significant time in the redistribution of information.

  15. Radiator selection for Space Station Solar Dynamic Power Systems

    Science.gov (United States)

    Fleming, Mike; Hoehn, Frank

    A study was conducted to define the best radiator for heat rejection of the Space Station Solar Dynamic Power System. Included in the study were radiators for both the Organic Rankine Cycle and Closed Brayton Cycle heat engines. A number of potential approaches were considered for the Organic Rankine Cycle and a constructable radiator was chosen. Detailed optimizations of this concept were conducted resulting in a baseline for inclusion into the ORC Preliminary Design. A number of approaches were also considered for the CBC radiator. For this application a deployed pumped liquid radiator was selected which was also refined resulting in a baseline for the CBC preliminary design. This paper reports the results and methodology of these studies and describes the preliminary designs of the Space Station Solar Dynamic Power System radiators for both of the candidate heat engine cycles.

  16. Technical Specifications, Seabrook Station, Unit 1 (Docket No. 50-443). Appendix ''A'' to License No. NPF-56

    International Nuclear Information System (INIS)

    1986-10-01

    This report provides specifications for the Seabrook Station Unit 1 reactor concerning: safety limits and limiting safety settings; limiting conditions for operation and surveillance requirements; design features; and administrative controls

  17. Complement: a key system for immune surveillance and homeostasis.

    Science.gov (United States)

    Ricklin, Daniel; Hajishengallis, George; Yang, Kun; Lambris, John D

    2010-09-01

    Nearly a century after the significance of the human complement system was recognized, we have come to realize that its functions extend far beyond the elimination of microbes. Complement acts as a rapid and efficient immune surveillance system that has distinct effects on healthy and altered host cells and foreign intruders. By eliminating cellular debris and infectious microbes, orchestrating immune responses and sending 'danger' signals, complement contributes substantially to homeostasis, but it can also take action against healthy cells if not properly controlled. This review describes our updated view of the function, structure and dynamics of the complement network, highlights its interconnection with immunity at large and with other endogenous pathways, and illustrates its multiple roles in homeostasis and disease.

  18. The applicability of animal health surveillance systems for post-market monitoring of potential adverse effects of genetically modified (GM) feed.

    Science.gov (United States)

    Vince, L; Kleter, G A; Kostov, K; Pfeiffer, D U; Guitian, J

    2018-04-20

    A facultative post market monitoring of potential health impacts of genetically modified (GM) feedstuffs on livestock consuming these feeds after pre-market risk assessment is under ongoing consideration. Within the IPAFEED database, scientific studies on health effects beyond performance in livestock and the results of a systematic search for evidence of outcome effects due to GM feed are consolidated. These outcomes were reviewed and checked for consistency in order to identify plausible syndromes suitable for conducting surveillance. The 24 selected studies showed no consistent changes in any health parameter. There were no repeated studies in any species by GM crop type and animal species. As such, there is insufficient evidence to inform the design of surveillance systems for detecting known adverse effects. Animal health surveillance systems have been proposed for the post market monitoring of potential adverse effects in animals. Such systems were evaluated for their applicability to the detection of hypothetical adverse effects and their strengths and weaknesses to detect syndromes of concern are presented. For known adverse effects, applied controlled post-market studies may yield conclusive and high-quality evidence. For detecting unknown adverse effects, the use of existing surveillance systems may still be of interest. A simulation tool developed within the project can be adapted and applied to existing surveillance systems to explore their applicability to the detection of potential adverse effects of GM feed. Copyright © 2018. Published by Elsevier Ltd.

  19. Large Efficient Intelligent Heating Relay Station System

    Science.gov (United States)

    Wu, C. Z.; Wei, X. G.; Wu, M. Q.

    2017-12-01

    The design of large efficient intelligent heating relay station system aims at the improvement of the existing heating system in our country, such as low heating efficiency, waste of energy and serious pollution, and the control still depends on the artificial problem. In this design, we first improve the existing plate heat exchanger. Secondly, the ATM89C51 is used to control the whole system and realize the intelligent control. The detection part is using the PT100 temperature sensor, pressure sensor, turbine flowmeter, heating temperature, detection of user end liquid flow, hydraulic, and real-time feedback, feedback signal to the microcontroller through the heating for users to adjust, realize the whole system more efficient, intelligent and energy-saving.

  20. Including test errors in evaluating surveillance test intervals

    International Nuclear Information System (INIS)

    Kim, I.S.; Samanta, P.K.; Martorell, S.; Vesely, W.E.

    1991-01-01

    Technical Specifications require surveillance testing to assure that the standby systems important to safety will start and perform their intended functions in the event of plant abnormality. However, as evidenced by operating experience, the surveillance tests may be adversely impact safety because of their undesirable side effects, such as initiation of plant transients during testing or wearing-out of safety systems due to testing. This paper first defines the concerns, i.e., the potential adverse effects of surveillance testing, from a risk perspective. Then, we present a methodology to evaluate the risk impact of those adverse effects, focusing on two important kinds of adverse impacts of surveillance testing: (1) risk impact of test-caused trips and (2) risk impact of test-caused equipment wear. The quantitative risk methodology is demonstrated with several surveillance tests conducted at boiling water reactors, such as the tests of the main steam isolation valves, the turbine overspeed protection system, and the emergency diesel generators. We present the results of the risk-effectiveness evaluation of surveillance test intervals, which compares the adverse risk impact with the beneficial risk impact of testing from potential failure detection, along with insights from sensitivity studies

  1. Surveillance

    DEFF Research Database (Denmark)

    Albrechtslund, Anders; Coeckelbergh, Mark; Matzner, Tobias

    Studying surveillance involves raising questions about the very nature of concepts such as information, technology, identity, space and power. Besides the maybe all too obvious ethical issues often discussed with regard to surveillance, there are several other angles and approaches that we should...... like to encourage. Therefore, our panel will focus on the philosophical, yet non-ethical issues of surveillance in order to stimulate an intense debate with the audience on the ethical implications of our enquiries. We also hope to provide a broader and deeper understanding of surveillance....

  2. Approaches to the Surveillance of Foodborne Disease: A Review of the Evidence.

    Science.gov (United States)

    Ford, Laura; Miller, Megge; Cawthorne, Amy; Fearnley, Emily; Kirk, Martyn

    2015-12-01

    Foodborne disease surveillance aims to reduce the burden of illness due to contaminated food. There are several different types of surveillance systems, including event-based surveillance, indicator-based surveillance, and integrated food chain surveillance. These approaches are not mutually exclusive, have overlapping data sources, require distinct capacities and resources, and can be considered a hierarchy, with each level being more complex and resulting in a greater ability to detect and control foodborne disease. Event-based surveillance is generally the least resource-intensive system and makes use of informal data sources. Indicator-based surveillance is seen as traditional notifiable disease surveillance and consists of routinely collected data. Integrated food chain surveillance is viewed as the optimal practice for conducting continuous risk analysis for foodborne diseases, but also requires significant ongoing resources and greater multisectoral collaboration compared to the other systems. Each country must determine the most appropriate structure for their surveillance system for foodborne diseases based on their available resources. This review explores the evidence on the principles, minimum capabilities, and minimum requirements of each type of surveillance and discusses examples from a range of countries. This review forms the evidence base for the Strengthening the Surveillance and Response for Foodborne Diseases: A Practical Manual.

  3. Environmental Control and Life Support Systems technology options for Space Station application

    Science.gov (United States)

    Hall, J. B., Jr.; Ferebee, M. J., Jr.; Sage, K. H.

    1985-01-01

    Continuous assessments regarding the suitability of candidate technologies for manned Space Stations will be needed over the next several years to obtain a basis for recommending the optimum system for an Initial Operating Capability (IOC) Space Station which is to be launched in the early 1990's. This paper has the objective to present analysis programs, the candidate recommendations, and the recommended approach for integration these candidates into the NASA Space Station reference configuration. Attention is given to ECLSS (Environmental Control and Life Support System) technology assessment program, an analysis approach for candidate technology recommendations, mission model variables, a candidate integration program, metabolic oxygen recovery, urine/flush water and all waste water recovery, wash water and condensate water recovery, and an integration analysis.

  4. Detecting Ebola with limited laboratory access in the Democratic Republic of Congo: evaluation of a clinical passive surveillance reporting system.

    Science.gov (United States)

    Ashbaugh, Hayley R; Kuang, Brandon; Gadoth, Adva; Alfonso, Vivian H; Mukadi, Patrick; Doshi, Reena H; Hoff, Nicole A; Sinai, Cyrus; Mossoko, Mathias; Kebela, Benoit Ilunga; Muyembe, Jean-Jacques; Wemakoy, Emile Okitolonda; Rimoin, Anne W

    2017-09-01

    Ebola virus disease (EVD) can be clinically severe and highly fatal, making surveillance efforts for early disease detection of paramount importance. In areas with limited access to laboratory testing, the Integrated Disease Surveillance and Response (IDSR) strategy in the Democratic Republic of Congo (DRC) may be a vital tool in improving outbreak response. Using DRC IDSR data from the nation's four EVD outbreak periods from 2007-2014, we assessed trends of Viral Hemorrhagic Fever (VHF) and EVD differential diagnoses reportable through IDSR. With official case counts from active surveillance of EVD outbreaks, we assessed accuracy of reporting through the IDSR passive surveillance system. Although the active and passive surveillance represent distinct sets of data, the two were correlated, suggesting that passive surveillance based only on clinical evaluation may be a useful predictor of true cases prior to laboratory confirmation. There were 438 suspect VHF cases reported through the IDSR system and 416 EVD cases officially recorded across the outbreaks examined. Although collected prior to official active surveillance cases, case reporting through the IDSR during the 2007, 2008 and 2012 outbreaks coincided with official EVD epidemic curves. Additionally, all outbreak areas experienced increases in suspected cases for both malaria and typhoid fever during EVD outbreaks, underscoring the importance of training health care workers in recognising EVD differential diagnoses and the potential for co-morbidities. © 2017 John Wiley & Sons Ltd.

  5. Containment/surveillance concepts for international safeguards in reprocessing plants

    International Nuclear Information System (INIS)

    Bleck, M.E.; Cameron, C.P.; Camp, A.L.

    1980-01-01

    This paper examines the potential role of advanced containment/surveillance instrumentation systems for international safeguards in reprocessing plants. Several conceptual systems for the surveillance of containment boundary penetrations in a reference reprocessing plant are described and evaluated. The results of the evaluation aid in understanding the potential capabilities and limitations of containment/surveillance as an international safeguards concept in this type of facility

  6. Semantic web technologies for video surveillance metadata

    OpenAIRE

    Poppe, Chris; Martens, Gaëtan; De Potter, Pieterjan; Van de Walle, Rik

    2012-01-01

    Video surveillance systems are growing in size and complexity. Such systems typically consist of integrated modules of different vendors to cope with the increasing demands on network and storage capacity, intelligent video analytics, picture quality, and enhanced visual interfaces. Within a surveillance system, relevant information (like technical details on the video sequences, or analysis results of the monitored environment) is described using metadata standards. However, different module...

  7. Surveillance of WWER-440 fuel performance

    International Nuclear Information System (INIS)

    Simko, J.; Urban, P.

    1999-01-01

    In this lecture next problems of surveillance of WWER-440 fuel performance are presented: surveillance of WWER-440 fuel performance at Mochovce NPP; basic data of WWER-440 reactor; in-core reactor measuring system 'SVRK'; basic level of SVRK; information output of basic level of SVRK; surveillance of fuel performance; table of permissible operation conditions of the reactor; limitation of the unit 1 power at the beginning of the operation; cyclic changes of power; future perspectives

  8. A Global Cancer Surveillance Framework Within Noncommunicable Disease Surveillance: Making the Case for Population-Based Cancer Registries.

    Science.gov (United States)

    Piñeros, Marion; Znaor, Ariana; Mery, Les; Bray, Freddie

    2017-01-01

    The growing burden of cancer among several major noncommunicable diseases (NCDs) requires national implementation of tailored public health surveillance. For many emerging economies where emphasis has traditionally been placed on the surveillance of communicable diseases, it is critical to understand the specificities of NCD surveillance and, within it, of cancer surveillance. We propose a general framework for cancer surveillance that permits monitoring the core components of cancer control. We examine communalities in approaches to the surveillance of other major NCDs as well as communicable diseases, illustrating key differences in the function, coverage, and reporting in each system. Although risk factor surveys and vital statistics registration are the foundation of surveillance of NCDs, population-based cancer registries play a unique fundamental role specific to cancer surveillance, providing indicators of population-based incidence and survival. With an onus now placed on governments to collect these data as part of the monitoring of NCD targets, the integration of cancer registries into existing and future NCD surveillance strategies is a vital requirement in all countries worldwide. The Global Initiative for Cancer Registry Development, endorsed by the World Health Organization, provides a means to enhance cancer surveillance capacity in low- and middle-income countries. © The Author 2017. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. Space Station Freedom (SSF) Data Management System (DMS) performance model data base

    Science.gov (United States)

    Stovall, John R.

    1993-01-01

    The purpose of this document was originally to be a working document summarizing Space Station Freedom (SSF) Data Management System (DMS) hardware and software design, configuration, performance and estimated loading data from a myriad of source documents such that the parameters provided could be used to build a dynamic performance model of the DMS. The document is published at this time as a close-out of the DMS performance modeling effort resulting from the Clinton Administration mandated Space Station Redesign. The DMS as documented in this report is no longer a part of the redesigned Space Station. The performance modeling effort was a joint undertaking between the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) Flight Data Systems Division (FDSD) and the NASA Ames Research Center (ARC) Spacecraft Data Systems Research Branch. The scope of this document is limited to the DMS core network through the Man Tended Configuration (MTC) as it existed prior to the 1993 Clinton Administration mandated Space Station Redesign. Data is provided for the Standard Data Processors (SDP's), Multiplexer/Demultiplexers (MDM's) and Mass Storage Units (MSU's). Planned future releases would have added the additional hardware and software descriptions needed to describe the complete DMS. Performance and loading data through the Permanent Manned Configuration (PMC) was to have been included as it became available. No future releases of this document are presently planned pending completion of the present Space Station Redesign activities and task reassessment.

  10. 47 CFR 90.656 - Responsibilities of base station licensees of Specialized Mobile Radio systems.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Responsibilities of base station licensees of... Bands § 90.656 Responsibilities of base station licensees of Specialized Mobile Radio systems. (a) The licensees of base stations that provide Specialized Mobile Radio service on a commercial basis of the use of...

  11. Development of a web-based epidemiological surveillance system with health system response for improving maternal and newborn health: Field-testing in Thailand.

    Science.gov (United States)

    Liabsuetrakul, Tippawan; Prappre, Tagoon; Pairot, Pakamas; Oumudee, Nurlisa; Islam, Monir

    2017-06-01

    Surveillance systems are yet to be integrated with health information systems for improving the health of pregnant mothers and their newborns, particularly in developing countries. This study aimed to develop a web-based epidemiological surveillance system for maternal and newborn health with integration of action-oriented responses and automatic data analysis with results presentations and to assess the system acceptance by nurses and doctors involved in various hospitals in southern Thailand. Freeware software and scripting languages were used. The system can be run on different platforms, and it is accessible via various electronic devices. Automatic data analysis with results presentations in the forms of graphs, tables and maps was part of the system. A multi-level security system was incorporated into the program. Most doctors and nurses involved in the study felt the system was easy to use and useful. This system can be integrated into country routine reporting system for monitoring maternal and newborn health and survival.

  12. Surveillance of systemic autoimmune rheumatic diseases using administrative data.

    Science.gov (United States)

    Bernatsky, S; Lix, L; Hanly, J G; Hudson, M; Badley, E; Peschken, C; Pineau, C A; Clarke, A E; Fortin, P R; Smith, M; Bélisle, P; Lagace, C; Bergeron, L; Joseph, L

    2011-04-01

    There is growing interest in developing tools and methods for the surveillance of chronic rheumatic diseases, using existing resources such as administrative health databases. To illustrate how this might work, we used population-based administrative data to estimate and compare the prevalence of systemic autoimmune rheumatic diseases (SARDs) across three Canadian provinces, assessing for regional differences and the effects of demographic factors. Cases of SARDs (systemic lupus erythematosus, scleroderma, primary Sjogren's, polymyositis/dermatomyositis) were ascertained from provincial physician billing and hospitalization data. We combined information from three case definitions, using hierarchical Bayesian latent class regression models that account for the imperfect nature of each case definition. Using methods that account for the imperfect nature of both billing and hospitalization databases, we estimated the over-all prevalence of SARDs to be approximately 2-3 cases per 1,000 residents. Stratified prevalence estimates suggested similar demographic trends across provinces (i.e. greater prevalence in females-versus-males, and in persons of older age). The prevalence in older females approached or exceeded 1 in 100, which may reflect the high burden of primary Sjogren's syndrome in this group. Adjusting for demographics, there was a greater prevalence in urban-versus-rural settings. In our work, prevalence estimates had good face validity and provided useful information about potential regional and demographic variations. Our results suggest that surveillance of some rheumatic diseases using administrative data may indeed be feasible. Our work highlights the usefulness of using multiple data sources, adjusting for the error in each.

  13. Systems Biology and Ratio-Based, Real-Time Disease Surveillance.

    Science.gov (United States)

    Fair, J M; Rivas, A L

    2015-08-01

    Most infectious disease surveillance methods are not well fit for early detection. To address such limitation, here we evaluated a ratio- and Systems Biology-based method that does not require prior knowledge on the identity of an infective agent. Using a reference group of birds experimentally infected with West Nile virus (WNV) and a problem group of unknown health status (except that they were WNV-negative and displayed inflammation), both groups were followed over 22 days and tested with a system that analyses blood leucocyte ratios. To test the ability of the method to discriminate small data sets, both the reference group (n = 5) and the problem group (n = 4) were small. The questions of interest were as follows: (i) whether individuals presenting inflammation (disease-positive or D+) can be distinguished from non-inflamed (disease-negative or D-) birds, (ii) whether two or more D+ stages can be detected and (iii) whether sample size influences detection. Within the problem group, the ratio-based method distinguished the following: (i) three (one D- and two D+) data classes; (ii) two (early and late) inflammatory stages; (iii) fast versus regular or slow responders; and (iv) individuals that recovered from those that remained inflamed. Because ratios differed in larger magnitudes (up to 48 times larger) than percentages, it is suggested that data patterns are likely to be recognized when disease surveillance methods are designed to measure inflammation and utilize ratios. Published 2013. This article is a U.S. Government work and is in the public domain in the USA.

  14. A new omni-directional multi-camera system for high resolution surveillance

    Science.gov (United States)

    Cogal, Omer; Akin, Abdulkadir; Seyid, Kerem; Popovic, Vladan; Schmid, Alexandre; Ott, Beat; Wellig, Peter; Leblebici, Yusuf

    2014-05-01

    Omni-directional high resolution surveillance has a wide application range in defense and security fields. Early systems used for this purpose are based on parabolic mirror or fisheye lens where distortion due to the nature of the optical elements cannot be avoided. Moreover, in such systems, the image resolution is limited to a single image sensor's image resolution. Recently, the Panoptic camera approach that mimics the eyes of flying insects using multiple imagers has been presented. This approach features a novel solution for constructing a spherically arranged wide FOV plenoptic imaging system where the omni-directional image quality is limited by low-end sensors. In this paper, an overview of current Panoptic camera designs is provided. New results for a very-high resolution visible spectrum imaging and recording system inspired from the Panoptic approach are presented. The GigaEye-1 system, with 44 single cameras and 22 FPGAs, is capable of recording omni-directional video in a 360°×100° FOV at 9.5 fps with a resolution over (17,700×4,650) pixels (82.3MP). Real-time video capturing capability is also verified at 30 fps for a resolution over (9,000×2,400) pixels (21.6MP). The next generation system with significantly higher resolution and real-time processing capacity, called GigaEye-2, is currently under development. The important capacity of GigaEye-1 opens the door to various post-processing techniques in surveillance domain such as large perimeter object tracking, very-high resolution depth map estimation and high dynamicrange imaging which are beyond standard stitching and panorama generation methods.

  15. Emergency Diesel Generation System Surveillance Test Policy Optimization Through Genetic Algorithms Using Non-Periodic Intervention Frequencies and Seasonal Constraints

    International Nuclear Information System (INIS)

    Lapa, Celso M.F.; Pereira, Claudio M.N.A.; Frutuoso e Melo, P.F.

    2002-01-01

    Nuclear standby safety systems must frequently, be submitted to periodic surveillance tests. The main reason is to detect, as soon as possible, the occurrence of unrevealed failure states. Such interventions may, however, affect the overall system availability due to component outages. Besides, as the components are demanded, deterioration by aging may occur, penalizing again the system performance. By these reasons, planning a good surveillance test policy implies in a trade-off between gains and overheads due to the surveillance test interventions. In order maximize the systems average availability during a given period of time, it has recently been developed a non-periodic surveillance test optimization methodology based on genetic algorithms (GA). The fact of allowing non-periodic tests turns the solution space much more flexible and schedules can be better adjusted, providing gains in the overall system average availability, when compared to those obtained by an optimized periodic tests scheme. The optimization problem becomes, however, more complex. Hence, the use of a powerful optimization technique, such as GAs, is required. Some particular features of certain systems can turn it advisable to introduce other specific constraints in the optimization problem. The Emergency Diesel Generation System (EDGS) of a Nuclear Power Plant (N-PP) is a good example for demonstrating the introduction of seasonal constraints in the optimization problem. This system is responsible for power supply during an external blackout. Therefore, it is desirable during periods of high blackout probability to maintain the system availability as high as possible. Previous applications have demonstrated the robustness and effectiveness of the methodology. However, no seasonal constraints have ever been imposed. This work aims at investigating the application of such methodology in the Angra-II Brazilian NPP EDGS surveillance test policy optimization, considering the blackout probability

  16. Output power distributions of mobile radio base stations based on network measurements

    International Nuclear Information System (INIS)

    Colombi, D; Thors, B; Persson, T; Törnevik, C; Wirén, N; Larsson, L-E

    2013-01-01

    In this work output power distributions of mobile radio base stations have been analyzed for 2G and 3G telecommunication systems. The approach is based on measurements in selected networks using performance surveillance tools part of the network Operational Support System (OSS). For the 3G network considered, direct measurements of output power levels were possible, while for the 2G networks, output power levels were estimated from measurements of traffic volumes. Both voice and data services were included in the investigation. Measurements were conducted for large geographical areas, to ensure good overall statistics, as well as for smaller areas to investigate the impact of different environments. For high traffic hours, the 90th percentile of the averaged output power was found to be below 65% and 45% of the available output power for the 2G and 3G systems, respectively.

  17. Output power distributions of mobile radio base stations based on network measurements

    Science.gov (United States)

    Colombi, D.; Thors, B.; Persson, T.; Wirén, N.; Larsson, L.-E.; Törnevik, C.

    2013-04-01

    In this work output power distributions of mobile radio base stations have been analyzed for 2G and 3G telecommunication systems. The approach is based on measurements in selected networks using performance surveillance tools part of the network Operational Support System (OSS). For the 3G network considered, direct measurements of output power levels were possible, while for the 2G networks, output power levels were estimated from measurements of traffic volumes. Both voice and data services were included in the investigation. Measurements were conducted for large geographical areas, to ensure good overall statistics, as well as for smaller areas to investigate the impact of different environments. For high traffic hours, the 90th percentile of the averaged output power was found to be below 65% and 45% of the available output power for the 2G and 3G systems, respectively.

  18. Establishment, test and evaluation of a prototype volcano surveillance system

    Science.gov (United States)

    Ward, P. L.; Eaton, J. P.; Endo, E.; Harlow, D.; Marquez, D.; Allen, R.

    1973-01-01

    A volcano-surveillance system utilizing 23 multilevel earthquake counters and 6 biaxial borehole tiltmeters is being installed and tested on 15 volcanoes in 4 States and 4 foreign countries. The purpose of this system is to give early warning when apparently dormant volcanoes are becoming active. The data are relayed through the ERTS-Data Collection System to Menlo Park for analysis. Installation was completed in 1972 on the volcanoes St. Augustine and Iliamna in Alaska, Kilauea in Hawaii, Baker, Rainier and St. Helens in Washington, Lassen in California, and at a site near Reykjavik, Iceland. Installation continues and should be completed in April 1973 on the volcanoes Santiaguito, Fuego, Agua and Pacaya in Guatemala, Izalco in El Salvador and San Cristobal, Telica and Cerro Negro in Nicaragua.

  19. Extending the GEMINI advanced review station development

    International Nuclear Information System (INIS)

    Kadner, S.; Spahn, W.; Pepper, S.

    1999-01-01

    Recent changes in the objectives of arms control agreements will have a dramatic impact on the nuclear non-proliferation regime. Meeting the demands of the nuclear non-proliferation regime will require the utilisation of the best available technological means for verification. The following discussion focuses on the increasing demands for safeguards with a view towards the possible technological solutions available to meet these demands. Based on the assumption that the gap between the international nonproliferation verification agenda and the available financial means can only be bridged via technology, the following discussion hopes to offer a compelling argument for the adoption of remote monitoring technologies in safeguards applications, specifically, data collection and review. The GEMINI Advanced Review Station (GARS) was developed with initial support from USPOTAS. This poster presentation presents the latest developments in GARS, including its extension to other surveillance systems under IAEA consideration, NDA applications, and networked safeguards. (author)

  20. Hospitalization records as a tool for evaluating performance of food- and water-borne disease surveillance systems: a Massachusetts case study.

    Science.gov (United States)

    Mor, Siobhan M; DeMaria, Alfred; Naumova, Elena N

    2014-01-01

    We outline a framework for evaluating food- and water-borne surveillance systems using hospitalization records, and demonstrate the approach using data on salmonellosis, campylobacteriosis and giardiasis in persons aged ≥65 years in Massachusetts. For each infection, and for each reporting jurisdiction, we generated smoothed standardized morbidity ratios (SMR) and surveillance to hospitalization ratios (SHR) by comparing observed surveillance counts with expected values or the number of hospitalized cases, respectively. We examined the spatial distribution of SHR and related this to the mean for the entire state. Through this approach municipalities that deviated from the typical experience were identified and suspected of under-reporting. Regression analysis revealed that SHR was a significant predictor of SMR, after adjusting for population age-structure. This confirms that the spatial "signal" depicted by surveillance is in part influenced by inconsistent testing and reporting practices since municipalities that reported fewer cases relative to the number of hospitalizations had a lower relative risk (as estimated by SMR). Periodic assessment of SHR has potential in assessing the performance of surveillance systems.

  1. Hospitalization records as a tool for evaluating performance of food- and water-borne disease surveillance systems: a Massachusetts case study.

    Directory of Open Access Journals (Sweden)

    Siobhan M Mor

    Full Text Available We outline a framework for evaluating food- and water-borne surveillance systems using hospitalization records, and demonstrate the approach using data on salmonellosis, campylobacteriosis and giardiasis in persons aged ≥65 years in Massachusetts. For each infection, and for each reporting jurisdiction, we generated smoothed standardized morbidity ratios (SMR and surveillance to hospitalization ratios (SHR by comparing observed surveillance counts with expected values or the number of hospitalized cases, respectively. We examined the spatial distribution of SHR and related this to the mean for the entire state. Through this approach municipalities that deviated from the typical experience were identified and suspected of under-reporting. Regression analysis revealed that SHR was a significant predictor of SMR, after adjusting for population age-structure. This confirms that the spatial "signal" depicted by surveillance is in part influenced by inconsistent testing and reporting practices since municipalities that reported fewer cases relative to the number of hospitalizations had a lower relative risk (as estimated by SMR. Periodic assessment of SHR has potential in assessing the performance of surveillance systems.

  2. A microcontroller-based data-acquisition system for meteorological station monitoring

    International Nuclear Information System (INIS)

    Rosiek, S.; Batlles, F.J.

    2008-01-01

    This paper presents a study of feasibility of different existing methodologies linked to field's data acquisition from remote meteorological stations. The data transmission serves to collect field's meteorological information, such as temperature, humidity and radiation. In our study the experimental data is registered in a weather station located about 100 km from University of Almeria. Various existing techniques are studied, especially Radio, GSM (global system of mobile communication) and GPRS (general packet radio service). In the result of these studies has been designed a system of field's data acquisition (herein referred as Meteologger) which we are going to present in this paper. The system is based on an ATmega 16 microcontroller, which scans 8 sensors together at any programmable intervals. This paper presents the study of the mentioned project, application and some main characteristics of the prototype system and its program. We attempt to implement the system, and subsequently present the performance of tests regarding the mentioned system. To verify its functioning some comparison of this measurement system with two others commercial data-acquisition system (Campbell and Hobo H8) has been carried out

  3. A microcontroller-based data-acquisition system for meteorological station monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Rosiek, S.; Batlles, F.J. [Dpto. Fisica Aplicada, Universidad de Almeria, 04120 Almeria (Spain)

    2008-12-15

    This paper presents a study of feasibility of different existing methodologies linked to field's data acquisition from remote meteorological stations. The data transmission serves to collect field's meteorological information, such as temperature, humidity and radiation. In our study the experimental data is registered in a weather station located about 100 km from the University of Almeria. Various existing techniques are studied, especially Radio, GSM (global system of mobile communication) and GPRS (general packet radio service). In the result of these studies has been designed a system of field's data acquisition (herein referred as Meteologger) which we are going to present in this paper. The system is based on an ATmega 16 microcontroller, which scans 8 sensors together at any programmable intervals. This paper presents the study of the mentioned project, application and some main characteristics of the prototype system and its program. We attempt to implement the system, and subsequently present the performance of tests regarding the mentioned system. To verify its functioning some comparison of this measurement system with two others commercial data-acquisition system (Campbell and Hobo H8) has been carried out. (author)

  4. Tritium surveillance around nuclear facilities in Japan

    International Nuclear Information System (INIS)

    Inoue, Y.; Kasida, Y.

    1978-01-01

    In order to measure the tritium levels in the environmental water around the nuclear facilities, the tritium surveillance program began in 1967 locally at Tsuruga and Mihama districts. Nowadays it has been expanded to the ten commercial nuclear power stations and three nuclear facilities. For samples whose tritium concentration is believed less than about 100 pCi/l, they were electrolytically enriched, and then counted by the liquid scintillation counter. Some of samples believed higher than 100 pCi/l were analysed without any enrichment by the low background liquid scintillation counters, Aloka LB 600 or Aloka LB 1. The results of each station are listed in Table. The sampling points corresponding to each results are shown in Figure. Tritium from the effluent was not reflected in all the land water and the tap water around the nuclear power stations and the nuclear facilities. Tritium concentration in rivers, streams, and reservoirs (pools) decreased exponentially from about 600 pCi/l in 1967 to about 150 pCi/l in 1972 at Tsuruga and Mihama, and 360 pCi/l in 1968 to 120 pCi/l in 1973 at Genkai, with the half life of about 2.5 years in both cases. After around 1972, tritium levels of river system in all districts of Japan kept nearly constant up to the end of 1975 and they were in the range from 100 to 300 pCi/l corresponding to the districts. Thereafter, it seems to start to decrease again in 1976. Sea water sampled at the intake of the station or on the seashore far from the outlet was regarded not to be influenced by the effluent from the nuclear reactors or facilities. Tritium concentration in these coastal waters decreased from 100 - 300 pCi/l in 1971 to 30 - 40 pCi/l in 1972 in Fukushima, Ibaraki and Fukui prefectures. (author)

  5. Mature data transport and command management services for the Space Station

    Science.gov (United States)

    Carper, R. D.

    1986-01-01

    The duplex space/ground/space data services for the Space Station are described. The need to separate the uplink data service functions from the command functions is discussed. Command management is a process shared by an operation control center and a command management system and consists of four functions: (1) uplink data communications, (2) management of the on-board computer, (3) flight resource allocation and management, and (4) real command management. The new data service capabilities provided by microprocessors, ground and flight nodes, and closed loop and open loop capabilities are studied. The need for and functions of a flight resource allocation management service are examined. The system is designed so only users can access the system; the problems encountered with open loop uplink access are analyzed. The procedures for delivery of operational, verification, computer, and surveillance and monitoring data directly to users are reviewed.

  6. Exchange of pressurizer safeguarding system at Biblis nuclear power station

    International Nuclear Information System (INIS)

    Weber, D.; Hofbeck, W.

    1991-01-01

    Valves and piping of the pressurizer safeguarding system are exchanged and reset in such a way that they are suitable not only for discharging steam, but also for discharging a water-steam mixture and hot pressurized water; for the emergency measure of primary depressurization by hand (bleed) in the event of failure of the entire feedwater supply and station black-out, and in the event of operational transients with supposed failure of the reactor scram (ATWS). To achieve this, in addition to the requirements of the pressurizer discharging station, changes have to be made to the valve drive to dominate the water loads. During the 1990 inspection this exchange of the pressurizer discharging station was performed at the Biblis A unit as the first German plant. (orig.) [de

  7. Towards a medium-range coastal station fog forecasting system

    CSIR Research Space (South Africa)

    Landman, S

    2013-09-01

    Full Text Available -1 29th Annual conference of South African Society for Atmospheric Sciences (SASAS) 2013 http://sasas.ukzn.ac.za/homepage.aspx Towards a Medium-Range Coastal Station Fog Forecasting System Stephanie Landman*1, Estelle Marx1, Willem A. Landman2...

  8. Low earth orbit environmental effects on the space station photovoltaic power generation systems

    International Nuclear Information System (INIS)

    Nahra, H.K.

    1977-01-01

    A summary of the Low Earth Orbital Environment, its impact on the photovoltaic power systems of the space station and the solutions implemented to resolve the environmental concerns or issues are described. Low Earth Orbital Environment (LEO) presents several concerns to the photovoltaic power systems of the space station. These concerns include atomic oxygen interaction with the polymeric substrate of the solar arrays, ionized environment effects on the array operating voltage, the effects of the meteoroids and debris impacts and penetration through the different layers of the solar cells and their circuits, and the high energy particle and radiation effects on the overall solar array performance. Potential solutions to some of the degrading environmental interactions that will provide the photovoltaic power system of the space station with the desired life are also summarized

  9. Establishing an emergency department syndromic surveillance system to support the London 2012 Olympic and Paralympic Games.

    Science.gov (United States)

    Elliot, Alex J; Hughes, Helen E; Hughes, Thomas C; Locker, Thomas E; Shannon, Tony; Heyworth, John; Wapling, Andy; Catchpole, Mike; Ibbotson, Sue; McCloskey, Brian; Smith, Gillian E

    2012-12-01

    The London 2012 Olympic and Paralympic Games is a mass gathering event that will present a major public health challenge. The Health Protection Agency, in collaboration with the College of Emergency Medicine, has established the Emergency Department Sentinel Syndromic Surveillance System (EDSSS) to support the public health surveillance requirements of the Games. This feasibility study assesses the usefulness of EDSSS in monitoring indicators of disease in the community. Daily counts of anonymised attendance data from six emergency departments across England were analysed by patient demographics (age, gender, partial postcode), triage coding and diagnosis codes. Generic and specific syndromic indicators were developed using aggregations of diagnosis codes recorded during each attendance. Over 339,000 attendances were recorded (26 July 2010 to 25 July 2011). The highest attendances recorded on weekdays between 10:00 and 11:00 and on weekends between 12:00 and 13:00. The mean daily attendance per emergency department was 257 (range 38-435). Syndromic indicators were developed including: respiratory, gastrointestinal, cardiac, acute respiratory infection, gastroenteritis and myocardial ischaemia. Respiratory and acute respiratory infection indicators peaked during December 2010, concomitant with national influenza activity, as monitored through other influenza surveillance systems. The EDSSS has been established to provide an enhanced surveillance system for the London 2012 Olympics. Further validation of the data will be required; however, the results from this initial descriptive study demonstrate the potential for identifying unusual and/or severe outbreaks of infectious disease, or other incidents with public health impact, within the community.

  10. Cooperating expert systems for Space Station - Power/thermal subsystem testbeds

    Science.gov (United States)

    Wong, Carla M.; Weeks, David J.; Sundberg, Gale R.; Healey, Kathleen L.; Dominick, Jeffrey S.

    1988-01-01

    The Systems Autonomy Demonstration Project (SADP) is a NASA-sponsored series of increasingly complex demonstrations to show the benefits of integrating knowledge-based systems with conventional process control in real-time, real-world problem domains that can facilitate the operations and availability of major Space Station distributed systems. This paper describes the system design, objectives, approaches, and status of each of the testbed knowledge-based systems. Simplified schematics of the systems are shown.

  11. Differences in physical activity prevalence and trends from 3 U.S. surveillance systems: NHIS, NHANES, and BRFSS.

    Science.gov (United States)

    Carlson, Susan A; Densmore, Dianna; Fulton, Janet E; Yore, Michelle M; Kohl, Harold W

    2009-01-01

    Three U.S. surveillance systems-National Health Interview Survey (NHIS), National Health and Nutrition Examination Survey (NHANES), and Behavioral Risk Factor Surveillance System (BRFSS)--estimate physical activity prevalence. Survey differences were examined qualitatively. Prevalence estimates by sex, age, and race/ethnicity were assessed for comparable survey periods. Trends were examined from NHIS 1998 to 2007, NHANES 1999 to 2006, and BRFSS 2001 to 2007. Age-adjusted prevalence estimates appeared most similar for NHIS 2005 (physically active: 30.2%, inactive: 40.7%) and NHANES 2005 to 2006 (physically active: 33.5%, inactive: 32.4%). In BRFSS 2005, prevalence of being physically active was 48.3% and inactive was 13.9%. Across all systems, men were more likely to be active than women; non-Hispanic whites were most likely to be active; as age increased, overall prevalence of being active decreased. Prevalence of being active exhibited a significant increasing trend only in BRFSS 2001 to 2007 (P < .001), while prevalence of being inactive decreased significantly in NHANES 1999 to 2006 (P < .001) and BRFSS 2001 to 2007 (P < .001). Different ways of assessing physical activity in surveillance systems result in different prevalence estimates. Before comparing estimates from different systems, all aspects of data collection and data analysis should be examined to determine if comparisons are appropriate.

  12. Evaluation of the enterovirus laboratory surveillance system in Denmark, 2010 to 2013.

    Science.gov (United States)

    Condell, Orla; Midgley, Sofie; Christiansen, Claus Bohn; Chen, Ming; Chen Nielsen, Xiaohui; Ellermann-Eriksen, Svend; Mølvadgaard, Mette; Schønning, Kristian; Vermedal Hoegh, Silje; Andersen, Peter Henrik; Voldstedlund, Marianne; Fischer, Thea Kølsen

    2016-05-05

    The primary aim of the Danish enterovirus (EV) surveillance system is to document absence of poliovirus infection. The conflict in Syria has left many children unvaccinated and movement from areas with polio cases to Europe calls for increased awareness to detect and respond to virus-transmission in a timely manner. We evaluate the national EV laboratory surveillance, to generate recommendations for system strengthening. The system was analysed for completeness of viral typing analysis and clinical information and timeliness of specimen collection, laboratory results and reporting of clinical information. Of 23,720 specimens screened, 2,202 (9.3%) were EV-positive. Submission of cerebrospinal fluid and faecal specimens from primary diagnostic laboratories was 79.5% complete (845/1,063), and varied by laboratory and patient age. EV genotypes were determined in 68.5% (979/1,430) of laboratory-confirmed cases, clinical information was available for 63.1% (903/1,430). Primary diagnostic results were available after a median of 1.4 days, typing results after 17 days, detailed clinical information after 33 days. The large number of samples typed demonstrated continued monitoring of EV-circulation in Denmark. The system could be strengthened by increasing the collection of supplementary faecal specimens, improving communication with primary diagnostic laboratories, adapting the laboratory typing methodology and collecting clinical information with electronic forms.

  13. Priorities for antibiotic resistance surveillance in Europe

    DEFF Research Database (Denmark)

    Fluit, A. C.; van der Bruggen, J. T.; Aarestrup, Frank Møller

    2006-01-01

    Antibiotic resistance is an increasing global problem. Surveillance studies are needed to monitor resistance development, to guide local empirical therapy, and to implement timely and adequate countermeasures. To achieve this, surveillance studies must have standardised methodologies, be longitud......Antibiotic resistance is an increasing global problem. Surveillance studies are needed to monitor resistance development, to guide local empirical therapy, and to implement timely and adequate countermeasures. To achieve this, surveillance studies must have standardised methodologies...... to the various reservoirs of antibiotic-resistant bacteria, such as hospitalised patients, nursing homes, the community, animals and food. Two studies that could serve as examples of tailored programmes are the European Antimicrobial Resistance Surveillance System (EARSS), which collects resistance data during...... of antibiotic resistance....

  14. Developing a Formal Specification for the Mission Systems of a Maritime Surveillance Aircraft

    DEFF Research Database (Denmark)

    Petrucci, Laure; Billington, Jonathan; Kristensen, Lars Michael

    2003-01-01

    The mission system of an aircraft is a complex real-time distributed system consisting of a mission control computer, different kinds of devices interconnected by a number of serial data buses. The complexity and real-time requirements of mission systems have motivated research into the applicati...... system with Coloured Petri Nets and analysed the model using state spaces. Here, we describe how this model was refined and modified to obtain a Coloured Petri Net model for the AP-3C Orion maritime surveillance aircraft....

  15. Catheter Associated Urinary Tract Infection Based on Surveillance Attributes in RSU Haji Surabaya

    Directory of Open Access Journals (Sweden)

    Spica Redina Vebrilian

    2017-03-01

    Full Text Available Surveillance system is instrumental in reducing the incidence of nosocomial infection. The implementation of this surveillance system is necessary in the hospital. Surveillance CAUTI is one of the focus prevention and infection control program in RSU Haji Surabaya 2015. The success of surveillance system highly depends on the association of attributes inside it. Surveillance attributes are indicator that describes the characteristics ofsurveillance system. In 2015, there was a delay in the collection of data reports which exceeds the prescribed time limit and there was also a lot of blank space in the confi rmation sheet. It affects the surveillance system in RSU Haji Surabaya. The purpose of this research is to evaluate the surveillance CAUTI based on the surveillance attributes in RSU Haji Surabaya2015. This research is a descriptive evaluative research. Subjects in this study are the surveillance attributes (simplicity, flexibility, acceptability, sensitivity, positive predictive value, representativeness, timeliness, data quality, and stability CAUTI in RSU Haji Surabaya, while survey respondents are IPCN, IPCLN, and head nurse. Data collected by interview and documentation study. The results showed that the attributes of surveillance is already has simplicity, high acceptability, high sensitivity, high positive predictive value, representative, and high stability. However, other attributes were not fl exible, not timeliness, and has a low data quality. Alternative solutions that can be done are to improve the regulatory function in every unit, establish standardization of hospital data, and manage reward and punishment system. Keywords: surveillance system, surveillance attributes, evaluation, nosocomial infections, CAUTI

  16. Intercomparison of auto- and cross-power spectral density surveillance systems for sodium boiling detection in fast reactors

    International Nuclear Information System (INIS)

    Ehrhardt, J.

    1979-01-01

    Theoretical and experimental investigations on detection systems for small narrow-band components in noise signals were conducted. These detectionn systems are based on the continuous surveillance of the power spectral density for characteristic peaks. Detection sensitivity for auto- and cross-correlation measurements was computed for signals with normally distributed amplitudes in dependence of signal coherence. The derived detection criteria allowed the comparison of auto- and cross-power spectral density surveillance. Theoretical results were confirmed in a number of experimental parameter studies. Special theoretical investigations were done for the optimal detection of local sodium boiling in liquid-metal fast breeder reactors

  17. Measuring costs of data collection at village clinics by village doctors for a syndromic surveillance system-a cross sectional survey from China.

    Science.gov (United States)

    Ding, Yan; Fei, Yang; Xu, Biao; Yang, Jun; Yan, Weirong; Diwan, Vinod K; Sauerborn, Rainer; Dong, Hengjin

    2015-07-25

    Studies into the costs of syndromic surveillance systems are rare, especially for estimating the direct costs involved in implementing and maintaining these systems. An Integrated Surveillance System in rural China (ISSC project), with the aim of providing an early warning system for outbreaks, was implemented; village clinics were the main surveillance units. Village doctors expressed their willingness to join in the surveillance if a proper subsidy was provided. This study aims to measure the costs of data collection by village clinics to provide a reference regarding the subsidy level required for village clinics to participate in data collection. We conducted a cross-sectional survey with a village clinic questionnaire and a staff questionnaire using a purposive sampling strategy. We tracked reported events using the ISSC internal database. Cost data included staff time, and the annual depreciation and opportunity costs of computers. We measured the village doctors' time costs for data collection by multiplying the number of full time employment equivalents devoted to the surveillance by the village doctors' annual salaries and benefits, which equaled their net incomes. We estimated the depreciation and opportunity costs of computers by calculating the equivalent annual computer cost and then allocating this to the surveillance based on the percentage usage. The estimated total annual cost of collecting data was 1,423 Chinese Renminbi (RMB) in 2012 (P25 = 857, P75 = 3284), including 1,250 RMB (P25 = 656, P75 = 3000) staff time costs and 134 RMB (P25 = 101, P75 = 335) depreciation and opportunity costs of computers. The total costs of collecting data from the village clinics for the syndromic surveillance system was calculated to be low compared with the individual net income in County A.

  18. The setting for ground based augmentation system station

    Science.gov (United States)

    Ni, Yude; Liu, Ruihua

    2007-11-01

    Based on the minimum field strength requirement within the whole GBAS service volume, this paper performs nominal link power budget for GBAS VHF data broadcast (VDB) system, and the required power transmitted from VDB system is derived. The paper elaborates the requirement of Desired-to-Undesired (D/U) signal ratio for a specific VHF airborne receiver to ensure the normal operation by the test, and presents the experimental method and results for acquiring the D/U signal ratios. The minimum geographical separations among GBAS, VOR and ILS stations are calculated according to the specifications of these three kinds of navigation systems.

  19. Surveillance of Human Rabies by National Authorities--A Global Survey.

    Science.gov (United States)

    Taylor, L H; Knopf, L

    2015-11-01

    Effective prevention of deaths due to human rabies is currently hampered by a lack of understanding of the scale of the problem, and the distribution of both animal and human cases across countries, regions and continents. Unfortunately, despite the severity of the disease, accurate data on which to assess these questions and to prioritize and direct public health interventions are not available for many parts of the world. This survey sought to understand the current global situation regarding the surveillance of human rabies. Data were collected from 91 countries across all continents and all categories of human rabies risk, generating the most complete and representative global data set currently available. Respondents were asked key questions about whether human rabies was a notifiable disease, how the surveillance system for human rabies operated and whether the respondent considered that the surveillance system was working effectively. Across the 91 countries from which data were collated, human rabies was a notifiable disease in all but eight. Despite international guidance, surveillance systems were very varied. Even where rabies is a notifiable disease, many countries had surveillance system judged to be ineffective, almost all of these being high and moderate rabies risk countries in Africa and Asia. Overall, 41% of the population covered by this survey (around 2.5 billion people) live in countries where there is no or ineffective rabies surveillance. The lack of robust surveillance is hindering rabies control efforts. However, whilst worldwide rabies surveillance would be improved if rabies were notifiable in all countries, many other challenges to the implementation of effective global human rabies surveillance systems remain. © 2015 Blackwell Verlag GmbH.

  20. Integrating malaria surveillance with climate data for outbreak detection and forecasting: the EPIDEMIA system.

    Science.gov (United States)

    Merkord, Christopher L; Liu, Yi; Mihretie, Abere; Gebrehiwot, Teklehaymanot; Awoke, Worku; Bayabil, Estifanos; Henebry, Geoffrey M; Kassa, Gebeyaw T; Lake, Mastewal; Wimberly, Michael C

    2017-02-23

    Early indication of an emerging malaria epidemic can provide an opportunity for proactive interventions. Challenges to the identification of nascent malaria epidemics include obtaining recent epidemiological surveillance data, spatially and temporally harmonizing this information with timely data on environmental precursors, applying models for early detection and early warning, and communicating results to public health officials. Automated web-based informatics systems can provide a solution to these problems, but their implementation in real-world settings has been limited. The Epidemic Prognosis Incorporating Disease and Environmental Monitoring for Integrated Assessment (EPIDEMIA) computer system was designed and implemented to integrate disease surveillance with environmental monitoring in support of operational malaria forecasting in the Amhara region of Ethiopia. A co-design workshop was held with computer scientists, epidemiological modelers, and public health partners to develop an initial list of system requirements. Subsequent updates to the system were based on feedback obtained from system evaluation workshops and assessments conducted by a steering committee of users in the public health sector. The system integrated epidemiological data uploaded weekly by the Amhara Regional Health Bureau with remotely-sensed environmental data freely available from online archives. Environmental data were acquired and processed automatically by the EASTWeb software program. Additional software was developed to implement a public health interface for data upload and download, harmonize the epidemiological and environmental data into a unified database, automatically update time series forecasting models, and generate formatted reports. Reporting features included district-level control charts and maps summarizing epidemiological indicators of emerging malaria outbreaks, environmental risk factors, and forecasts of future malaria risk. Successful implementation and

  1. Disturbance analysis and surveillance system scoping and feasibility system. Final report

    International Nuclear Information System (INIS)

    Dowling, E.F.; Benedict, B.J.; Snidow, N.L.

    1981-05-01

    This report summarizes the results of a disturbance analysis and surveillance system (DASS) scoping and feasibility study conducted by The Babcock and Wilcox Company, Burns and Roe, Incorporated, General Physics Corporation, and Duke Power Company for Sandia Laboratories and the US Department of Energy. The report addresses selection of DASS goals and functions, development of a design concept for a DASS based on monitoring the nuclear plant subsystem functions and states against predetermined targets, and creation of engineering procedures for the design and implementation of a DASS. The validity of the procedures is evaluated based on application to a subset of the DASS functions. It is concluded that the DASS design concept is a feasible, systematic, and modular approach to plant disturbance identification

  2. Control of Flywheel Energy Storage Systems in Electrical Vehicle Charging Stations

    DEFF Research Database (Denmark)

    Sun, Bo

    energy storage system (FESS). The proposed PhD project supports a corresponding smart control strategy that could be termed “charging station to grid (CS2G)”. It explores the possibility of using a dedicated energy storage system (FESS) within the charging station to alleviate grid and market conditions...... converters is built and analyzed. |Based on modeling analysis, centralized and distributed control methods are both explored to realize the coordination control of each components in the system. Specially, this project proposes a “dc voltage vs speed” droop strategy for FESS control based on distributed bus...... function method when the system switches its operation behavior between two modes. Finally, a downscaled FCS prototype with FESS is built in the intelligent MG lab, and experiments and hardware-in-loop simulation results are conducted to verify the effectiveness and feasibility with the proposed FCS...

  3. Honey bee surveillance: a tool for understanding and improving honey bee health.

    Science.gov (United States)

    Lee, Kathleen; Steinhauer, Nathalie; Travis, Dominic A; Meixner, Marina D; Deen, John; vanEngelsdorp, Dennis

    2015-08-01

    Honey bee surveillance systems are increasingly used to characterize honey bee health and disease burdens of bees in different regions and/or over time. In addition to quantifying disease prevalence, surveillance systems can identify risk factors associated with colony morbidity and mortality. Surveillance systems are often observational, and prove particularly useful when searching for risk factors in real world complex systems. We review recent examples of surveillance systems with particular emphasis on how these efforts have helped increase our understanding of honey bee health. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Security and Privacy in Video Surveillance: Requirements and Challenges

    DEFF Research Database (Denmark)

    Mahmood Rajpoot, Qasim; Jensen, Christian D.

    2014-01-01

    observed by the system. Several techniques to protect the privacy of individuals have therefore been proposed, but very little research work has focused on the specific security requirements of video surveillance data (in transit or in storage) and on authorizing access to this data. In this paper, we...... present a general model of video surveillance systems that will help identify the major security and privacy requirements for a video surveillance system and we use this model to identify practical challenges in ensuring the security of video surveillance data in all stages (in transit and at rest). Our...... study shows a gap between the identified security requirements and the proposed security solutions where future research efforts may focus in this domain....

  5. Integrated monitoring and surveillance system demonstration project: Phase I accomplishments

    International Nuclear Information System (INIS)

    Aumeier, S.E.; Walters, B.G.; Crawford, D.C.

    1997-01-01

    The authors present the results of the Integrated Monitoring and Surveillance System (IMSS) demonstration project Phase I efforts. The rationale behind IMSS development is reviewed and progress in each of the 5 basic tasks is detailed. Significant results include decisions to use Echelon LonWorks networking protocol and Microsoft Access for the data system needs, a preliminary design for the plutonium canning system glovebox, identification of facilities and materials available for the demonstration, determination of possibly affected facility documentation, and a preliminary list of available sensor technologies. Recently imposed changes in the overall project schedule and scope are also discussed and budgetary requirements for competition of Phase II presented. The results show that the IMSS demonstration project team has met and in many cases exceeded the commitments made for Phase I deliverables

  6. Prototyping of a Situation Awareness System in the Maritime Surveillance

    International Nuclear Information System (INIS)

    Handayani, D O D; Shah, A; Sediono, W

    2013-01-01

    This paper discusses about the design of a Situation Awareness (SA) system to support vessel crews and control room operators in improving the decision making process. The architecture of the system is ontology based. The vessel crews and control room operators may face a loss of SA. They may have limited cognitive abilities which make it difficult to make a decision in a high stress level, short time availability and continuously evolving situation with incomplete information. In this work, we describe the application of Semantic Web Rule Language to represent corresponding knowledge in the maritime surveillance domain. The result of this research will demonstrate that an ontology based system can be used to remodel the information into a meaningful and valuable form to predict the future states of SA and improve the decision making process

  7. A data-capture system for post-marketing surveillance of drugs that integrates with hospital electronic health records

    Directory of Open Access Journals (Sweden)

    Yamamoto K

    2011-04-01

    Full Text Available Keiichi Yamamoto1, Shigemi Matsumoto2, Kazuhiro Yanagihara2, Satoshi Teramukai1, Masanori Fukushima1,2,31Department of Clinical Trial Design and Management, Translational Research Center, Kyoto University Hospital, Kyoto, Japan; 2Outpatient Oncology Unit, Kyoto University Hospital, Kyoto, Japan; 3Translational Research Informatics Center, Foundation for Biomedical Research and Innovation, Kobe, JapanPurpose: In conventional clinical studies, the cost of data management for the purposes of quality control tend to be high and collecting paper-based case report forms (CRFs can be burdensome, because paper-based CRFs must be developed and filled out for each clinical study protocol. Use of electronic health records (EHRs for this purpose could reduce costs and improve data quality in clinical studies. Kyoto University Hospital launched an EHR system in January 2005. At the same time, a replicate of that database was established for other purposes. At the Outpatient Oncology Unit of Kyoto University Hospital we developed a data-capture system that includes a cancer clinical database system and a data warehouse for outcomes studies. This system allows us to accumulate data at low cost and apply it to various uses in clinical or outcomes studies. Here we report on the application of this system to the post-marketing surveillance of drugs.Methods: We evaluated the availability of this system and identified problems for future development. With this system investigators can register cases for post-marketing surveillance, and the registered cases are listed on a screen. When CRFs for a particular case are required, data can be extracted from the list and CRFs are produced in PDF format.Results and conclusion: In this study we confirmed the applicability of our new system to post-marketing surveillance in providing prompt and efficient data exchange. We expect it to reduce the cost of data management and analysis and to improve the quality of data in post

  8. Users manual data base MATSURV. Reactor pressure vessel material surveillance data management system

    International Nuclear Information System (INIS)

    Kenworthy, L.D.; Tether, C.D.

    1980-02-01

    This Users Guide to the data management system MATSURV has been prepared to assist the user in all facets of the task of processing data related to reactor pressure vessel materials surveillance; preparation of raw data for input, input of data, modification of existing data, retrieval and display of data, and the creation of data reports. MATSURV is structured upon the System 2000 data base management system which is maintained on the IBM 370/168 computer at National Institutes of Health. An overview of System 2000 is provided

  9. SCORPION II persistent surveillance system with universal gateway

    Science.gov (United States)

    Coster, Michael; Chambers, Jonathan; Brunck, Albert

    2009-05-01

    This paper addresses improvements and benefits derived from the next generation Northrop Grumman SCORPION II family of persistent surveillance and target recognition systems produced by the Xetron campus in Cincinnati, Ohio. SCORPION II reduces the size, weight, and cost of all SCORPION components in a flexible, field programmable system that is easier to conceal, backward compatible, and enables integration of over forty Unattended Ground Sensor (UGS) and camera types from a variety of manufacturers, with a modular approach to supporting multiple Line of Sight (LOS) and Beyond Line of Sight (BLOS) communications interfaces. Since 1998 Northrop Grumman has been integrating best in class sensors with its proven universal modular Gateway to provide encrypted data exfiltration to Common Operational Picture (COP) systems and remote sensor command and control. In addition to being fed to COP systems, SCORPION and SCORPION II data can be directly processed using a common sensor status graphical user interface (GUI) that allows for viewing and analysis of images and sensor data from up to seven hundred SCORPION system Gateways on single or multiple displays. This GUI enables a large amount of sensor data and imagery to be used for actionable intelligence as well as remote sensor command and control by a minimum number of analysts.

  10. Programmable Ultra-Lightweight System Adaptable Radio Satellite Base Station

    Science.gov (United States)

    Varnavas, Kosta; Sims, Herb

    2015-01-01

    With the explosion of the CubeSat, small sat, and nanosat markets, the need for a robust, highly capable, yet affordable satellite base station, capable of telemetry capture and relay, is significant. The Programmable Ultra-Lightweight System Adaptable Radio (PULSAR) is NASA Marshall Space Flight Center's (MSFC's) software-defined digital radio, developed with previous Technology Investment Programs and Technology Transfer Office resources. The current PULSAR will have achieved a Technology Readiness Level-6 by the end of FY 2014. The extensibility of the PULSAR will allow it to be adapted to perform the tasks of a mobile base station capable of commanding, receiving, and processing satellite, rover, or planetary probe data streams with an appropriate antenna.

  11. Oconee Nuclear Station, Units 1, 2, and 3. Semiannual operating report, January--June 1975

    International Nuclear Information System (INIS)

    1975-01-01

    Information is presented concerning operations, performance characteristics, changes, tests, inspections, containment leak tests, maintenance, primary coolant chemistry, station staff changes, reservoir investigations, plume mapping, and operational environmental radioactivity monitoring data for oconee Units 1, 2, and 3. The non-radiological environmental surveillance program is also described. (FS)

  12. Mobile Surveillance and Monitoring Robots

    International Nuclear Information System (INIS)

    Kimberly, Howard R.; Shipers, Larry R.

    1999-01-01

    Long-term nuclear material storage will require in-vault data verification, sensor testing, error and alarm response, inventory, and maintenance operations. System concept development efforts for a comprehensive nuclear material management system have identified the use of a small flexible mobile automation platform to perform these surveillance and maintenance operations. In order to have near-term wide-range application in the Complex, a mobile surveillance system must be small, flexible, and adaptable enough to allow retrofit into existing special nuclear material facilities. The objective of the Mobile Surveillance and Monitoring Robot project is to satisfy these needs by development of a human scale mobile robot to monitor the state of health, physical security and safety of items in storage and process; recognize and respond to alarms, threats, and off-normal operating conditions; and perform material handling and maintenance operations. The system will integrate a tool kit of onboard sensors and monitors, maintenance equipment and capability, and SNL developed non-lethal threat response technology with the intelligence to identify threats and develop and implement first response strategies for abnormal signals and alarm conditions. System versatility will be enhanced by incorporating a robot arm, vision and force sensing, robust obstacle avoidance, and appropriate monitoring and sensing equipment

  13. Development of an automated checkout, service and maintenance system for a Space Station EVAS

    Science.gov (United States)

    Abeles, Fred J.; Tri, Terry; Blaser, Robert

    1988-01-01

    The development of a new operational system for the Space Station will minimize the time normally spent on performing on-orbit checkout, servicing, and maintenance of an extravehicular activity system of the Space Station. This system, the Checkout, Servicing, and Maintenance System (COSM), is composed of interactive control software interfacing with software simulations of hardware components. The major elements covered in detail include the controller, the EMU simulator and the regenerative life support system. The operational requirements and interactions of the individual elements as well as the protocols are also discussed.

  14. Surface-water surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Saldi, K.A.; Dirkes, R.L.; Blanton, M.L.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the Surface water on and near the Hanford Site is monitored to determine the potential effects of Hanford operations. Surface water at Hanford includes the Columbia River, riverbank springs, ponds located on the Hanford Site, and offsite water systems directly east and across the Columbia River from the Hanford Site, and offsite water systems directly east and across the Columbia River from the Hanford Site. Columbia River sediments are also included in this discussion. Tables 5.3.1 and 5.3.2 summarize the sampling locations, sample types, sampling frequencies, and sample analyses included in surface-water surveillance activities during 1994. Sample locations are also identified in Figure 5.3.1. This section describes the surveillance effort and summarizes the results for these aquatic environments. Detailed analytical results are reported by Bisping (1995).

  15. Surface-water surveillance

    International Nuclear Information System (INIS)

    Saldi, K.A.; Dirkes, R.L.; Blanton, M.L.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the Surface water on and near the Hanford Site is monitored to determine the potential effects of Hanford operations. Surface water at Hanford includes the Columbia River, riverbank springs, ponds located on the Hanford Site, and offsite water systems directly east and across the Columbia River from the Hanford Site, and offsite water systems directly east and across the Columbia River from the Hanford Site. Columbia River sediments are also included in this discussion. Tables 5.3.1 and 5.3.2 summarize the sampling locations, sample types, sampling frequencies, and sample analyses included in surface-water surveillance activities during 1994. Sample locations are also identified in Figure 5.3.1. This section describes the surveillance effort and summarizes the results for these aquatic environments. Detailed analytical results are reported by Bisping (1995)

  16. A new surveillance system for undiagnosed serious infectious illness for the London 2012 Olympic and Paralympic Games.

    Science.gov (United States)

    Heinsbroek, E; Said, B; Kirkbride, H

    2012-08-02

    A new surveillance system was developed to detect possible new or emerging infections presenting as undiagnosed serious infectious illness (USII) for use during the London 2012 Olympic and Paralympic Games. Designated clinicians in sentinel adult and paediatric intensive care units (ICU/ PICUs) reported USII using an online reporting tool or provided a weekly nil notification. Reported cases were investigated for epidemiological links. A pilot study was undertaken for six months between January and July 2011 to evaluate the feasibility and acceptability of the system. In this six-month period, 5 adults and 13 children were reported by six participating units (3 ICUs, 3 PICUs). Of these 18 patients, 12 were reported within four days after admission to an ICU/PICU. Nine patients were subsequently diagnosed and were thus excluded from the surveillance. Therefore, only nine cases of USII were reported. No clustering was identified.On the basis of the pilot study, we conclude that the system is able to detect cases of USII and is feasible and acceptable to users. USII surveillance has been extended to a total of 19 sentinel units in London and the south-east of England during the London 2012 Olympic and Paralympic Games.

  17. A New Molecular Surveillance System for Leishmaniasis

    Science.gov (United States)

    Pandey, Kishor; Pandey, Basu Dev; Mallik, Arun Kumar; Acharya, Jyoti; Kato, Kentaro; Kaneko, Osamu; Ferreira, Pedro Eduardo

    2014-01-01

    Abstract. Presently, global efforts are being made to control and eradicate the deadliest tropical diseases through the improvement of adequate interventions. A critical point for programs to succeed is the prompt and accurate diagnosis in endemic regions. Rapid diagnostic tests (RDTs) are being massively deployed and used to improve diagnosis in tropical countries. In the present report, we evaluated the hypothesis of, after use for diagnosis, the reuse of the Leishmania RDT kit as a DNA source, which can be used downstream as a molecular surveillance and/or quality control tool. As a proof of principle, a polymerase chain reaction-based method was used to detect Leishmania spp. minicircle kinetoplast DNA from leishmaniasis RDT kits. Our results show that Leishmania spp. DNA can be extracted from used RDTs and may constitute an important, reliable, and affordable tool to assist in future leishmaniasis molecular surveillance methods. PMID:24752687

  18. A vision-based driver nighttime assistance and surveillance system based on intelligent image sensing techniques and a heterogamous dual-core embedded system architecture.

    Science.gov (United States)

    Chen, Yen-Lin; Chiang, Hsin-Han; Chiang, Chuan-Yen; Liu, Chuan-Ming; Yuan, Shyan-Ming; Wang, Jenq-Haur

    2012-01-01

    This study proposes a vision-based intelligent nighttime driver assistance and surveillance system (VIDASS system) implemented by a set of embedded software components and modules, and integrates these modules to accomplish a component-based system framework on an embedded heterogamous dual-core platform. Therefore, this study develops and implements computer vision and sensing techniques of nighttime vehicle detection, collision warning determination, and traffic event recording. The proposed system processes the road-scene frames in front of the host car captured from CCD sensors mounted on the host vehicle. These vision-based sensing and processing technologies are integrated and implemented on an ARM-DSP heterogamous dual-core embedded platform. Peripheral devices, including image grabbing devices, communication modules, and other in-vehicle control devices, are also integrated to form an in-vehicle-embedded vision-based nighttime driver assistance and surveillance system.

  19. Implementation of a Multimodal Mobile System for Point-of-Sale Surveillance: Lessons Learned From Case Studies in Washington, DC, and New York City.

    Science.gov (United States)

    Cantrell, Jennifer; Ganz, Ollie; Ilakkuvan, Vinu; Tacelosky, Michael; Kreslake, Jennifer; Moon-Howard, Joyce; Aidala, Angela; Vallone, Donna; Anesetti-Rothermel, Andrew; Kirchner, Thomas R

    2015-01-01

    In tobacco control and other fields, point-of-sale surveillance of the retail environment is critical for understanding industry marketing of products and informing public health practice. Innovations in mobile technology can improve existing, paper-based surveillance methods, yet few studies describe in detail how to operationalize the use of technology in public health surveillance. The aims of this paper are to share implementation strategies and lessons learned from 2 tobacco, point-of-sale surveillance projects to inform and prepare public health researchers and practitioners to implement new mobile technologies in retail point-of-sale surveillance systems. From 2011 to 2013, 2 point-of-sale surveillance pilot projects were conducted in Washington, DC, and New York, New York, to capture information about the tobacco retail environment and test the feasibility of a multimodal mobile data collection system, which included capabilities for audio or video recording data, electronic photographs, electronic location data, and a centralized back-end server and dashboard. We established a preimplementation field testing process for both projects, which involved a series of rapid and iterative tests to inform decisions and establish protocols around key components of the project. Important components of field testing included choosing a mobile phone that met project criteria, establishing an efficient workflow and accessible user interfaces for each component of the system, training and providing technical support to fieldworkers, and developing processes to integrate data from multiple sources into back-end systems that can be utilized in real-time. A well-planned implementation process is critical for successful use and performance of multimodal mobile surveillance systems. Guidelines for implementation include (1) the need to establish and allow time for an iterative testing framework for resolving technical and logistical challenges; (2) developing a streamlined

  20. Implementation of a Multimodal Mobile System for Point-of-Sale Surveillance: Lessons Learned From Case Studies in Washington, DC, and New York City

    Science.gov (United States)

    Ganz, Ollie; Ilakkuvan, Vinu; Tacelosky, Michael; Kreslake, Jennifer; Moon-Howard, Joyce; Aidala, Angela; Vallone, Donna; Anesetti-Rothermel, Andrew; Kirchner, Thomas R

    2015-01-01

    Background In tobacco control and other fields, point-of-sale surveillance of the retail environment is critical for understanding industry marketing of products and informing public health practice. Innovations in mobile technology can improve existing, paper-based surveillance methods, yet few studies describe in detail how to operationalize the use of technology in public health surveillance. Objective The aims of this paper are to share implementation strategies and lessons learned from 2 tobacco, point-of-sale surveillance projects to inform and prepare public health researchers and practitioners to implement new mobile technologies in retail point-of-sale surveillance systems. Methods From 2011 to 2013, 2 point-of-sale surveillance pilot projects were conducted in Washington, DC, and New York, New York, to capture information about the tobacco retail environment and test the feasibility of a multimodal mobile data collection system, which included capabilities for audio or video recording data, electronic photographs, electronic location data, and a centralized back-end server and dashboard. We established a preimplementation field testing process for both projects, which involved a series of rapid and iterative tests to inform decisions and establish protocols around key components of the project. Results Important components of field testing included choosing a mobile phone that met project criteria, establishing an efficient workflow and accessible user interfaces for each component of the system, training and providing technical support to fieldworkers, and developing processes to integrate data from multiple sources into back-end systems that can be utilized in real-time. Conclusions A well-planned implementation process is critical for successful use and performance of multimodal mobile surveillance systems. Guidelines for implementation include (1) the need to establish and allow time for an iterative testing framework for resolving technical and