WorldWideScience

Sample records for surveillance system implemented

  1. Next Generation Surveillance System (NGSS): Field Implementation & Associated Developments

    International Nuclear Information System (INIS)

    Hadfi, G.; John, M.; Liguori, C.; Moeslinger, M.; Murray, J.; Rocchi, S.

    2015-01-01

    The NGSS is the product of more than five years of development between the IAEA, other Inspectorates, Member State Support Programmes, and commercial vendors. The product of these efforts has now matured into the field implementation stage. This paper details the goals, achievements and challenges experienced during the implementation phase and associated developments of the project. NGSS procurement was subject to the IAEA's stringent procurement policies involving independent third party assessments to assure supplier reliability and competitive pricing controls. More than 1200 surveillance cameras currently installed in facilities worldwide will be replaced by NGSS within the next 4 to 5 years. Joint use procedures have been established taking advantage of the technical capabilities integrated within the design of the NGSS which allow for multiple inspectorates and States to securely and independently share and review data. Utilization of outdated facility infrastructure poses many challenges to implementation efforts; these were met with innovative technical solutions to take advantage of cost benefits allowed in its re-utilization. New partnerships were established with Member States, regulatory bodies and nuclear power plant operators for new nuclear facilities under construction, to address infrastructural requirements spanning the next half century. The utilization of the IAEA's well-established PKI infrastructure enhances data security features and usability with regard to data sharing, key management and joint use of the NGSS system data. Embedded inventory reporting capability aids electronic inventory verification of safeguards equipment, simplifying accountability, configuration control and troubleshooting of installed systems. Current developments ongoing within the project include the design of hardware and software components for use of the system in special applications (e.g., underwater and outdoor installations, mechanism to

  2. Design and Implementation of an Embedded Smart Intruder Surveillance System

    Directory of Open Access Journals (Sweden)

    Sabri Naseer

    2018-01-01

    Full Text Available Remote and scattered valuable and sensitive locations such as labs and offices inside university campus need efficient monitoring and warning system. As well as scattered area and belonging. This research presents a Real-Time intruder Surveillance System based on a single board computer (SBC. Thus the design and development of a cost effective surveillance management system based SBC that can be deployed efficiently in remote and scattered locations such as universities belonging. The fusion of embedded Python codes with SBC that attached to cameras, Long distance sensors, alerting circuitry and wireless module presents a novel integration based effective cost solution and enhances SBC of much flexibility of improvement and development for pervasive remote locations. The system proves the high integrity of smooth working with web application, it’s cost effective and thus can be deployed as many of units to seize and concisely covered remote and scattered area as well as university belonging and departments. The system can be administrated by a remote user sparsely or geographically away from any networked workstation. The proposed solution offers efficient stand alone, flexibility to upgrade and cheap development and installation as well as cost effective ubiquitous surveillance solution. In conclusion, the system acceptable boundaries of successful intruder recognition and warning alert are computed between 1m and 3m distance of intruder from system camera. Recognition rate of 95% and 83% are achieved and the successful warning alert were in the range of 86-97%.

  3. Implementation of nuclear material surveillance system based on the digital video capture card and counter

    International Nuclear Information System (INIS)

    Lee, Sang Yoon; Song, Dae Yong; Ko, Won Il; Ha, Jang Ho; Kim, Ho Dong

    2003-07-01

    In this paper, the implementation techniques of nuclear material surveillance system based on the digital video capture board and digital counter was described. The surveillance system that is to be developed is consist of CCD cameras, neutron monitors, and PC for data acquisition. To develop the system, the properties of the PCI based capture board and counter was investigated, and the characteristics of related SDK library was summarized. This report could be used for the developers who want to develop the surveillance system for various experimental environments based on the DVR and sensors using Borland C++ Builder

  4. Design, Implementation, and Evaluation of the Adolescents and Surveillance System for the Obesity Prevention Project.

    Science.gov (United States)

    Tabacchi, Garden; Bianco, Antonino; Alessi, Nicola; Filippi, Anna Rita; Napoli, Giuseppe; Jemni, Monèm; Censi, Laura; Breda, João; Schumann, Nathali Lehmann; Firenze, Alberto; Vitale, Francesco; Mammina, Caterina

    2016-03-01

    The Adolescents Surveillance System for Obesity prevention (ASSO) Project aimed at developing standardized and web-based tools for collecting data on adolescents' obesity and its potential determinants. This has been implemented and piloted in the local area of Palermo city, Italy. The aim of the present study is to provide an overview of the Project's design, implementation, and evaluation, highlighting all the aspects for a potential scale-up of the surveillance system on the whole national territory and abroad, as a sustainable and effective source of data.The overall structure and management, the ASSO-toolkit, the ASSO-NutFit software, and all developed and used procedures for recruiting, training, and data collecting/analyzing are addressed. An interim evaluation has been performed through a feasibility study; a final Project evaluation has been performed reporting the Strengths, Weaknesses, Opportunities, and Threats (SWOT) and the attributes that a surveillance system should have.This article provides a detailed overview of the Project and highlights that ASSO can be considered a valid, logical, coherent, efficient, and sustainable surveillance system that is consistent with countries' needs and priorities.The system developed by the ASSO Project provides high-quality data and complies with several characteristics typical of a suitable surveillance system. It has a potential of being adopted within the National Health Service and other countries' Health Services for monitoring adolescents' obesity and its determinants, such as food intakes, behaviors, physical activity, and fitness profiles.

  5. Design and implementation of distributed multimedia surveillance system based on object-oriented middleware

    Science.gov (United States)

    Cao, Xuesong; Jiang, Ling; Hu, Ruimin

    2006-10-01

    Currently, the applications of surveillance system have been increasingly widespread. But there are few surveillance platforms that can meet the requirement of large-scale, cross-regional, and flexible surveillance business. In the paper, we present a distributed surveillance system platform to improve safety and security of the society. The system is constructed by an object-oriented middleware called as Internet Communications Engine (ICE). This middleware helps our platform to integrate a lot of surveillance resource of the society and accommodate diverse range of surveillance industry requirements. In the follow sections, we will describe in detail the design concepts of system and introduce traits of ICE.

  6. Implementing a Childhood Cancer Outcomes Surveillance System Within a Population-Based Cancer Registry

    Directory of Open Access Journals (Sweden)

    Oscar Ramirez

    2018-03-01

    Full Text Available Purpose: Approximately 80% of cases of childhood cancer occur in low- and middle-income countries and are associated with high mortality rates. Assessing outcomes is essential for designing effective strategies to improve outcomes equally worldwide. We implemented a real-time surveillance system, VIGICANCER, embedded in a population-based cancer registry (PBCR to assess childhood cancer outcomes. Methods: VIGICANCER was established in 2009 as an integral part of Cali’s PBCR to collect real-time data on outcomes of patients (age < 19 years with a new diagnosis of cancer treated in pediatric oncology units in Cali, Colombia. Baseline and follow-up data (death, relapse, treatment abandonment, second neoplasms were collected from medical records, hospital discharge logs, pathology reports, death certificates, and the National Public Health Insurance database. A quality assurance process was implemented for the system. Results: From 2009 to 2013, data from 1,242 patients were included in VIGICANCER: 32% of patients were younger than 5 years, 55% were male, and 15% were Afro-descendants. International Classification of Childhood Cancer group I diagnoses predominated in all age groups except children younger than 1 year old, in whom CNS tumors predominated. Five-year overall survival for all cancers was 51.7% (95% CI, 47.9% to 55.4% for children (< 15 years, and 39.4% (95% CI, 29.8% to 50.5% for adolescents (15 to 18.9 years. Five-year overall survival for acute lymphoblastic leukemia was 55.6% (95% CI, 48.5% to 62.2%. Conclusion: Our study demonstrates the feasibility of implementing a real-time childhood cancer outcomes surveillance system embedded in a PBCR that can guide interventions to improve clinical outcomes in low- and middle-income countries.

  7. Implementation of Syndromic Surveillance Systems in Two Rural Villages in Senegal.

    Science.gov (United States)

    Abat, Cédric; Colson, Philippe; Chaudet, Hervé; Rolain, Jean-Marc; Bassene, Hubert; Diallo, Aldiouma; Mediannikov, Oleg; Fenollar, Florence; Raoult, Didier; Sokhna, Cheikh

    2016-12-01

    Infectious diseases still represent a major challenge for humanity. In this context, their surveillance is critical. From 2010 to 2016, two Point-Of-Care (POC) laboratories have been successfully implemented in the rural Saloum region of Senegal. In parallel, a homemade syndromic surveillance system called EPIMIC was implemented to monitor infectious diseases using data produced by the POC laboratory of the Timone hospital in Marseille, France. The aim of this study is to describe the steps necessary for implementing EPIMIC using data routinely produced by two POC laboratories (POC-L) established in rural Senegal villages. After improving EPIMIC, we started to monitor the 15 pathogens routinely diagnosed in the two POC-L using the same methodology we used in France. In 5 years, 2,577 deduplicated patients-samples couples from 775 different patients have been tested in the Dielmo and Ndiop POC-L. 739 deduplicated patients-samples couples were found to be positive to at least one of the tested pathogens. The retrospective analysis of the Dielmo and Ndiop POC data with EPIMIC allowed to generate 443 alarms. Since January 2016, 316 deduplicated patients-samples couples collected from 298 different patients were processed in the Niakhar POC laboratory. 56 deduplicated patients-samples couples were found to be positive to at least one of the tested pathogens. The retrospective analysis of the data of the Niakhar POC laboratory with EPIMIC allowed to generate 14 alarms. Although some improvements are still needed, EPIMIC has been successfully spread using data routinely produced by two rural POC-L in Senegal, West Africa.

  8. Implementation of Syndromic Surveillance Systems in Two Rural Villages in Senegal.

    Directory of Open Access Journals (Sweden)

    Cédric Abat

    2016-12-01

    Full Text Available Infectious diseases still represent a major challenge for humanity. In this context, their surveillance is critical. From 2010 to 2016, two Point-Of-Care (POC laboratories have been successfully implemented in the rural Saloum region of Senegal. In parallel, a homemade syndromic surveillance system called EPIMIC was implemented to monitor infectious diseases using data produced by the POC laboratory of the Timone hospital in Marseille, France. The aim of this study is to describe the steps necessary for implementing EPIMIC using data routinely produced by two POC laboratories (POC-L established in rural Senegal villages. After improving EPIMIC, we started to monitor the 15 pathogens routinely diagnosed in the two POC-L using the same methodology we used in France. In 5 years, 2,577 deduplicated patients-samples couples from 775 different patients have been tested in the Dielmo and Ndiop POC-L. 739 deduplicated patients-samples couples were found to be positive to at least one of the tested pathogens. The retrospective analysis of the Dielmo and Ndiop POC data with EPIMIC allowed to generate 443 alarms. Since January 2016, 316 deduplicated patients-samples couples collected from 298 different patients were processed in the Niakhar POC laboratory. 56 deduplicated patients-samples couples were found to be positive to at least one of the tested pathogens. The retrospective analysis of the data of the Niakhar POC laboratory with EPIMIC allowed to generate 14 alarms. Although some improvements are still needed, EPIMIC has been successfully spread using data routinely produced by two rural POC-L in Senegal, West Africa.

  9. Challenges in the implementation of an electronic surveillance system in a resource-limited setting: Alerta, in Peru

    Directory of Open Access Journals (Sweden)

    Soto Giselle

    2008-11-01

    Full Text Available Abstract Background Infectious disease surveillance is a primary public health function in resource-limited settings. In 2003, an electronic disease surveillance system (Alerta was established in the Peruvian Navy with support from the U.S. Naval Medical Research Center Detachment (NMRCD. Many challenges arose during the implementation process, and a variety of solutions were applied. The purpose of this paper is to identify and discuss these issues. Methods This is a retrospective description of the Alerta implementation. After a thoughtful evaluation according to the Centers for Disease Control and Prevention (CDC guidelines, the main challenges to implementation were identified and solutions were devised in the context of a resource-limited setting, Peru. Results After four years of operation, we have identified a number of challenges in implementing and operating this electronic disease surveillance system. These can be divided into the following categories: (1 issues with personnel and stakeholders; (2 issues with resources in a developing setting; (3 issues with processes involved in the collection of data and operation of the system; and (4 issues with organization at the central hub. Some of the challenges are unique to resource-limited settings, but many are applicable for any surveillance system. For each of these challenges, we developed feasible solutions that are discussed. Conclusion There are many challenges to overcome when implementing an electronic disease surveillance system, not only related to technology issues. A comprehensive approach is required for success, including: technical support, personnel management, effective training, and cultural sensitivity in order to assure the effective deployment of an electronic disease surveillance system.

  10. A Best Practices Model for Implementing Successful Electronic Disease Surveillance Systems: Insights from Peru and Around the Globe

    Science.gov (United States)

    2013-06-03

    reports provided detailed information for each case such as age, residential district, gender, and laboratory data. For instance, dengue fever and... region in Management of Childhood Observational study I) Training component I) Experienced high staff turnover. Brazil ; Inclusion Illness) aims to reduce...proved to be key to the successful implementation of such a system. National and regional surveillance teams performed the critical functions of disease

  11. A Smart Card-Based Electronic School Absenteeism System for Influenza-Like Illness Surveillance in Hong Kong: Design, Implementation, and Feasibility Assessment.

    Science.gov (United States)

    Ip, Dennis Km; Lau, Eric Hy; So, Hau Chi; Xiao, Jingyi; Lam, Chi Kin; Fang, Vicky J; Tam, Yat Hung; Leung, Gabriel M; Cowling, Benjamin J

    2017-10-06

    School-aged children have the highest incidence of respiratory virus infections each year, and transmission of respiratory viruses such as influenza virus can be a major concern in school settings. School absenteeism data have been employed as a component of influenza surveillance systems in some locations. Data timeliness and system acceptance remain as key determinants affecting the usefulness of a prospective surveillance system. The aim of this study was to assess the feasibility of implementing an electronic school absenteeism surveillance system using smart card-based technology for influenza-like illness (ILI) surveillance among a representative network of local primary and secondary schools in Hong Kong. We designed and implemented a surveillance system according to the Protocol for a Standardized information infrastructure for Pandemic and Emerging infectious disease Response (PROSPER). We employed an existing smart card-based education and school administration platform for data capture, customized the user interface, and used additional back end systems built for other downstream surveillance steps. We invited local schools to participate and collected absenteeism data by the implemented system. We compared temporal trend of the absenteeism data with data from existing community sentinel and laboratory surveillance data. We designed and implemented an ILI surveillance system utilizing smart card-based attendance tracking approach for data capture. We implemented the surveillance system in a total of 107 schools (including 66 primary schools and 41 secondary schools), covering a total of 75,052 children. The system successfully captured information on absences for 2 consecutive academic years (2012-2013 and 2013-2014). The absenteeism data we collected from the system reflected ILI activity in the community, with an upsurge in disease activity detected up to 1 to 2 weeks preceding other existing surveillance systems. We designed and implemented a novel

  12. Lessons From the Implementation of Mo-Buzz, a Mobile Pandemic Surveillance System for Dengue.

    Science.gov (United States)

    Lwin, May Oo; Jayasundar, Karthikayen; Sheldenkar, Anita; Wijayamuni, Ruwan; Wimalaratne, Prasad; Ernst, Kacey C; Foo, Schubert

    2017-10-02

    Approximately 128 countries and 3.9 billion people are at risk of dengue infection. Incidence of dengue has increased over the past decades, becoming a growing public health concern for countries with populations that are increasingly susceptible to this vector-borne disease, such as Sri Lanka. Almost 55,150 dengue cases were reported in Sri Lanka in 2016, with more than 30.40% of cases (n=16,767) originating from Colombo, which struggles with an outdated manual paper-based dengue outbreak management system. Community education and outreach about dengue are also executed using paper-based media channels such as pamphlets and brochures. Yet, Sri Lanka is one of the countries with the most affordable rates of mobile services in the world, with penetration rates higher than most developing countries. To combat the issues of an exhausted dengue management system and to make use of new technology, in 2015, a mobile participatory system for dengue surveillance called Mo-Buzz was developed and launched in Colombo, Sri Lanka. This paper describes the system's components and uptake, along with other similar disease surveillance systems. We developed Mo-Buzz and tested its feasibility for dengue. Two versions of the app were developed. The first was for use by public health inspectors (PHIs) to digitize form filling and recording of site visit information, and track dengue outbreaks on a real-time dengue hotspot map using the global positioning system technology. The system also provides updated dengue infographics and educational materials for the PHIs to educate the general public. The second version of Mo-Buzz was created for use by the general public. This system uses dynamic mapping to help educate and inform the general public about potential outbreak regions and allow them to report dengue symptoms and post pictures of potential dengue mosquito-breeding sites, which are automatically sent to the health authorities. Targeted alerts can be sent to users depending on

  13. Present and future of desertification in Spain: Implementation of a surveillance system to prevent land degradation.

    Science.gov (United States)

    Martínez-Valderrama, Jaime; Ibáñez, Javier; Del Barrio, Gabriel; Sanjuán, Maria E; Alcalá, Francisco J; Martínez-Vicente, Silvio; Ruiz, Alberto; Puigdefábregas, Juan

    2016-09-01

    Mitigation strategies are crucial for desertification given that once degradation starts, other solutions are extremely expensive or unworkable. Prevention is key to handle this problem and solutions should be based on spotting and deactivating the stressors of the system. Following this topic, the Spanish Plan of Action to Combat Desertification (SPACD) created the basis for implementing two innovative approaches to evaluate the threat of land degradation in the country. This paper presents tools for preventing desertification in the form of a geomatic approach to enable the periodic assessments of the status and trends of land condition. Also System Dynamics modelling has been used to integrate bio-physical and socio-economic aspects of desertification to explain and analyse degradation in the main hot spots detected in Spain. The 2dRUE procedure was implemented to map the land-condition status by comparing potential land productivity according to water availability, the limiting factor in arid lands, with plant-biomass data. This assessment showed that 20% of the territory is degraded and an additional 1% is actively degrading. System Dynamics modelling was applied to study the five desertification landscapes identified by the SPACD. The risk analysis, implemented on these models, concluded that 'Herbaceous crops affected by soil erosion' is the landscape most at risk, while the Plackett-Burman sensitivity analysis used to rank the factors highlighted the supremacy of climatic factors above socioeconomic drivers. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Implementation of a data fusion algorithm for RODS, a real-time outbreak and disease surveillance system.

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Douglas (Sandia National Laboratories, Livermore, CA); Gray, Genetha Anne (Sandia National Laboratories, Livermore, CA)

    2005-10-01

    Due to the nature of many infectious agents, such as anthrax, symptoms may either take several days to manifest or resemble those of less serious illnesses leading to misdiagnosis. Thus, bioterrorism attacks that include the release of such agents are particularly dangerous and potentially deadly. For this reason, a system is needed for the quick and correct identification of disease outbreaks. The Real-time Outbreak Disease Surveillance System (RODS), initially developed by Carnegie Mellon University and the University of Pittsburgh, was created to meet this need. The RODS software implements different classifiers for pertinent health surveillance data in order to determine whether or not an outbreak has occurred. In an effort to improve the capability of RODS at detecting outbreaks, we incorporate a data fusion method. Data fusion is used to improve the results of a single classification by combining the output of multiple classifiers. This paper documents the first stages of the development of a data fusion system that can combine the output of the classifiers included in RODS.

  15. Implementation of an integrated on-line process surveillance and diagnostic system at the Halden reactor project: MOAS

    International Nuclear Information System (INIS)

    Kim, I.S.; Grini, R.-E.; Nilsen, S.

    2001-01-01

    MOAS is an integrated on-line process surveillance and diagnostic system that uses several different models for knowledge acquisition and diagnostic reasoning, such as goal-tree success-tree model, process monitor trees, and sensor failure diagnosis trees. Within these models, the knowledge of the process and its operation, including deep knowledge, like mass balance or controller algorithm, is incorporated. During an extensive review, made as part of the integrated diagnosis system project of the Halden reactor project, MOAS (Maryland Operator Advisory System) was identified as one of the most thorough systems developed thus far. MOAS encompasses diverse functional aspects that are required for an effective process disturbance management: (1) intelligent process monitoring and alarming, (2) on-line sensor data validation and sensor failure diagnosis, (3) on-line hardware (besides sensors) failure diagnosis, and (4) real-time corrective measure synthesis. The MOAS methodology was used for the NORS (Nokia Research Simulator) process at the Halden man-machine laboratory HAMMLAB of the OECD Halden reactor project. The performance tests of MOAS, implemented in G2 real-time expert system shell, show that MOAS successfully carries out its intended functions, i.e. quickly recognizing an occurring disturbance, correctly diagnosing its cause, and presenting advice on its control to the operator. The lessons learned and insights gained during the implementation and performance tests also are discussed

  16. Laser surveillance system (LASSY)

    International Nuclear Information System (INIS)

    Boeck, H.; Hammer, J.

    1988-01-01

    The development progress during the reporting period 1988 of the laser surveillance system of spent fuel pools is summarized. The present engineered system comes close to a final version for field application as all technical questions have been solved in 1988. 14 figs., 1 tab. (Author)

  17. Laser surveillance system (LASSY)

    International Nuclear Information System (INIS)

    Boeck, H.

    1991-09-01

    Laser Surveillance System (LASSY) is a beam of laser light which scans a plane above the water or under-water in a spent-fuel pond. The system can detect different objects and estimates its coordinates and distance as well. LASSY can operate in stand-alone configuration or in combination with a video surveillance to trigger signal to a videorecorder. The recorded information on LASSY computer's disk comprises date, time, start and stop angle of detected alarm, the size of the disturbance indicated in number of deviated points and some other information. The information given by the laser system cannot be fully substituted by TV camera pictures since the scanning beam creates a horizontal surveillance plan. The engineered prototype laser system long-term field test has been carried out in Soluggia (Italy) and has shown its feasibility and reliability under the conditions of real spent fuel storage pond. The verification of the alarm table on the LASSY computer with the recorded video pictures of TV surveillance system confirmed that all alarm situations have been detected. 5 refs

  18. Monitoring the introduction of pneumococcal conjugate vaccines into West Africa: design and implementation of a population-based surveillance system.

    Directory of Open Access Journals (Sweden)

    Grant A Mackenzie

    2012-01-01

    Full Text Available Routine use of pneumococcal conjugate vaccines (PCVs in developing countries is expected to lead to a significant reduction in childhood deaths. However, PCVs have been associated with replacement disease with non-vaccine serotypes. We established a population-based surveillance system to document the direct and indirect impact of PCVs on the incidence of invasive pneumococcal disease (IPD and radiological pneumonia in those aged 2 months and older in The Gambia, and to monitor changes in serotype-specific IPD. Here we describe how this surveillance system was set up and is being operated as a partnership between the Medical Research Council Unit and the Gambian Government. This surveillance system is expected to provide crucial information for immunisation policy and serves as a potential model for those introducing routine PCV vaccination in diverse settings.

  19. Implementation of a Multimodal Mobile System for Point-of-Sale Surveillance: Lessons Learned From Case Studies in Washington, DC, and New York City.

    Science.gov (United States)

    Cantrell, Jennifer; Ganz, Ollie; Ilakkuvan, Vinu; Tacelosky, Michael; Kreslake, Jennifer; Moon-Howard, Joyce; Aidala, Angela; Vallone, Donna; Anesetti-Rothermel, Andrew; Kirchner, Thomas R

    2015-01-01

    In tobacco control and other fields, point-of-sale surveillance of the retail environment is critical for understanding industry marketing of products and informing public health practice. Innovations in mobile technology can improve existing, paper-based surveillance methods, yet few studies describe in detail how to operationalize the use of technology in public health surveillance. The aims of this paper are to share implementation strategies and lessons learned from 2 tobacco, point-of-sale surveillance projects to inform and prepare public health researchers and practitioners to implement new mobile technologies in retail point-of-sale surveillance systems. From 2011 to 2013, 2 point-of-sale surveillance pilot projects were conducted in Washington, DC, and New York, New York, to capture information about the tobacco retail environment and test the feasibility of a multimodal mobile data collection system, which included capabilities for audio or video recording data, electronic photographs, electronic location data, and a centralized back-end server and dashboard. We established a preimplementation field testing process for both projects, which involved a series of rapid and iterative tests to inform decisions and establish protocols around key components of the project. Important components of field testing included choosing a mobile phone that met project criteria, establishing an efficient workflow and accessible user interfaces for each component of the system, training and providing technical support to fieldworkers, and developing processes to integrate data from multiple sources into back-end systems that can be utilized in real-time. A well-planned implementation process is critical for successful use and performance of multimodal mobile surveillance systems. Guidelines for implementation include (1) the need to establish and allow time for an iterative testing framework for resolving technical and logistical challenges; (2) developing a streamlined

  20. Implementation of a Multimodal Mobile System for Point-of-Sale Surveillance: Lessons Learned From Case Studies in Washington, DC, and New York City

    Science.gov (United States)

    Ganz, Ollie; Ilakkuvan, Vinu; Tacelosky, Michael; Kreslake, Jennifer; Moon-Howard, Joyce; Aidala, Angela; Vallone, Donna; Anesetti-Rothermel, Andrew; Kirchner, Thomas R

    2015-01-01

    Background In tobacco control and other fields, point-of-sale surveillance of the retail environment is critical for understanding industry marketing of products and informing public health practice. Innovations in mobile technology can improve existing, paper-based surveillance methods, yet few studies describe in detail how to operationalize the use of technology in public health surveillance. Objective The aims of this paper are to share implementation strategies and lessons learned from 2 tobacco, point-of-sale surveillance projects to inform and prepare public health researchers and practitioners to implement new mobile technologies in retail point-of-sale surveillance systems. Methods From 2011 to 2013, 2 point-of-sale surveillance pilot projects were conducted in Washington, DC, and New York, New York, to capture information about the tobacco retail environment and test the feasibility of a multimodal mobile data collection system, which included capabilities for audio or video recording data, electronic photographs, electronic location data, and a centralized back-end server and dashboard. We established a preimplementation field testing process for both projects, which involved a series of rapid and iterative tests to inform decisions and establish protocols around key components of the project. Results Important components of field testing included choosing a mobile phone that met project criteria, establishing an efficient workflow and accessible user interfaces for each component of the system, training and providing technical support to fieldworkers, and developing processes to integrate data from multiple sources into back-end systems that can be utilized in real-time. Conclusions A well-planned implementation process is critical for successful use and performance of multimodal mobile surveillance systems. Guidelines for implementation include (1) the need to establish and allow time for an iterative testing framework for resolving technical and

  1. The value of information: Current challenges in surveillance implementation.

    Science.gov (United States)

    Stärk, Katharina D C; Häsler, Barbara

    2015-11-01

    Animal health surveillance is a complex activity that involves multiple stakeholders and provides decision support across sectors. Despite progress in the design of surveillance systems, some technical challenges remain, specifically for emerging hazards. Surveillance can also be impacted by political interests and costly consequences of case reporting, particularly in relation to international trade. Constraints on surveillance can therefore be of technical, economic and political nature. From an economic perspective, both surveillance and intervention are resource-using activities that are part of a mitigation strategy. Surveillance provides information for intervention decisions and thereby helps to offset negative effects of animal disease and to reduce the decision uncertainty associated with choices on disease control. It thus creates monetary and non-monetary benefits, both of which may be challenging to quantify. The technical relationships between surveillance, intervention and loss avoidance have not been established for most hazards despite being important consideration for investment decisions. Therefore, surveillance cannot just be maximised to minimise intervention costs. Economic appraisals of surveillance need to be done on a case by case basis for any hazard considering both surveillance and intervention performance, the losses avoided and the values attached to them. This can be achieved by using an evaluation approach which provides a systematic investigation of the worth or merit of surveillance activities. Evaluation is driven by a specific evaluation question which for surveillance systems commonly considers effectiveness, efficiency, implementation and/or compliance issues. More work is needed to provide guidance on the appropriate selection of evaluation attributes and general good practice in surveillance evaluation. Due to technical challenges, economic constraints and variable levels of capacity, the implementation of surveillance systems

  2. Disaster prevention surveillance system

    International Nuclear Information System (INIS)

    Nara, Satoru; Kamiya, Eisei

    2001-01-01

    Fuji Electric Co., Ltd. has supplied many management systems to nuclear reactor institution. 'The nuclear countermeasures-against-calamities special-measures' was enforced. A nuclear entrepreneur has devised the measure about expansion prevention and restoration of a calamity while it endeavors after prevention of generating of a nuclear calamity. Our company have supplied the 'disaster prevention surveillance system' to the Japan Atomic Energy Research Institute Tokai Research Establishment aiming at strengthening of the monitoring function at the time (after the accident) of the accident used as one of the above-mentioned measures. A 'disaster prevention surveillance system' can share the information on the accident spot in an on-site command place, an activity headquarters, and support organizations, when the serious accident happens. This system is composed of various sensors (temperature, pressure and radiation), cameras, computers and network. (author)

  3. SCORPIO - VVER core surveillance system

    International Nuclear Information System (INIS)

    Zalesky, K.; Svarny, J.; Novak, L.; Rosol, J.; Horanes, A.

    1997-01-01

    The Halden Project has developed the core surveillance system SCORPIO which has two parallel modes of operation: the Core Follow Mode and the Predictive Mode. The main motivation behind the development of SCORPIO is to make a practical tool for reactor operators which can increase the quality and quantity of information presented on core status and dynamic behavior. This can first of all improve plant safety as undesired core conditions are detected and prevented. Secondly, more flexible and efficient plant operation is made possible. So far the system has only been implemented on western PWRs but the basic concept is applicable to a wide range of reactor including WWERs. The main differences between WWERs and typical western PWRs with respect to core surveillance requirements are outlined. The development of a WWER version of SCORPIO was initiated in cooperation with the Nuclear Research Institute at Rez and industry partners in the Czech Republic. The first system will be installed at the Dukovany NPP. (author)

  4. Wallops Ship Surveillance System

    Science.gov (United States)

    Smith, Donna C.

    2011-01-01

    Approved as a Wallops control center backup system, the Wallops Ship Surveillance Software is a day-of-launch risk analysis tool for spaceport activities. The system calculates impact probabilities and displays ship locations relative to boundary lines. It enables rapid analysis of possible flight paths to preclude the need to cancel launches and allow execution of launches in a timely manner. Its design is based on low-cost, large-customer- base elements including personal computers, the Windows operating system, C/C++ object-oriented software, and network interfaces. In conformance with the NASA software safety standard, the system is designed to ensure that it does not falsely report a safe-for-launch condition. To improve the current ship surveillance method, the system is designed to prevent delay of launch under a safe-for-launch condition. A single workstation is designated the controller of the official ship information and the official risk analysis. Copies of this information are shared with other networked workstations. The program design is divided into five subsystems areas: 1. Communication Link -- threads that control the networking of workstations; 2. Contact List -- a thread that controls a list of protected item (ocean vessel) information; 3. Hazard List -- threads that control a list of hazardous item (debris) information and associated risk calculation information; 4. Display -- threads that control operator inputs and screen display outputs; and 5. Archive -- a thread that controls archive file read and write access. Currently, most of the hazard list thread and parts of other threads are being reused as part of a new ship surveillance system, under the SureTrak project.

  5. Sonoma Persistent Surveillance System

    Energy Technology Data Exchange (ETDEWEB)

    Pennington, D M

    2006-03-24

    Sonoma offers the first cost-effective, broad-area, high-resolution, real-time motion imagery system for surveillance applications. Sonoma is unique in its ability to provide continuous, real-time video imagery of an area the size of a small city with resolutions sufficient to track 8,000 moving objects in the field of view. At higher resolutions and over smaller areas, Sonoma can even track the movement of individual people. The visual impact of the data available from Sonoma is already causing a paradigm shift in the architecture and operation of other surveillance systems. Sonoma is expected to cost just one-tenth the price of comparably sized sensor systems. Cameras mounted on an airborne platform constantly monitor an area, feeding data to the ground for real-time analysis. Sonoma was designed to provide real-time data for actionable intelligence in situations such as monitoring traffic, special events, border security, and harbors. If a Sonoma system had been available in the aftermath of the Katrina and Rita hurricanes, emergency responders would have had real-time information on roads, water levels, and traffic conditions, perhaps saving many lives.

  6. A Google Earth-based surveillance system for schistosomiasis japonica implemented in the lower reaches of the Yangtze River, China

    Directory of Open Access Journals (Sweden)

    Sun Le-Ping

    2011-11-01

    Full Text Available Abstract Background Due to the success of the national schistosomiasis control programme in China, transmission has been sufficiently reduced in many areas to severely limit identification of areas at risk by conventional snail surveys only. In this study, we imported Google Earth technology and a Global Positioning System (GPS into the monitoring system for schistosomiasis surveillance of the banks of the Yangtze River in Jiangsu Province, China. Methods A total of 45 sites were selected and the risk was assessed monthly by water exposure of sentinel mice at these sites from May to September in 2009 and 2010. The results were assembled and broadcast via the Google Earth platform. Results The intensity of schistosomiasis transmission showed peaks of risk in June and September of 2009, while there was only one small peak in June in 2010 as the number of detected positive transmission sites dropped dramatically that year thanks to improved mollusciciding. River ports were found to be areas of particular risk, but ferry terminals and other centres of river-related activities were also problematic. Conclusions The results confirm that the surveillance system can be rapidly updated and easily maintained, which proves the Google Earth approach to be a user-friendly, inexpensive warning system for schistosomiasis risk.

  7. Smart sensing surveillance system

    Science.gov (United States)

    Hsu, Charles; Chu, Kai-Dee; O'Looney, James; Blake, Michael; Rutar, Colleen

    2010-04-01

    An effective public safety sensor system for heavily-populated applications requires sophisticated and geographically-distributed infrastructures, centralized supervision, and deployment of large-scale security and surveillance networks. Artificial intelligence in sensor systems is a critical design to raise awareness levels, improve the performance of the system and adapt to a changing scenario and environment. In this paper, a highly-distributed, fault-tolerant, and energy-efficient Smart Sensing Surveillance System (S4) is presented to efficiently provide a 24/7 and all weather security operation in crowded environments or restricted areas. Technically, the S4 consists of a number of distributed sensor nodes integrated with specific passive sensors to rapidly collect, process, and disseminate heterogeneous sensor data from near omni-directions. These distributed sensor nodes can cooperatively work to send immediate security information when new objects appear. When the new objects are detected, the S4 will smartly select the available node with a Pan- Tilt- Zoom- (PTZ) Electro-Optics EO/IR camera to track the objects and capture associated imagery. The S4 provides applicable advanced on-board digital image processing capabilities to detect and track the specific objects. The imaging detection operations include unattended object detection, human feature and behavior detection, and configurable alert triggers, etc. Other imaging processes can be updated to meet specific requirements and operations. In the S4, all the sensor nodes are connected with a robust, reconfigurable, LPI/LPD (Low Probability of Intercept/ Low Probability of Detect) wireless mesh network using Ultra-wide band (UWB) RF technology. This UWB RF technology can provide an ad-hoc, secure mesh network and capability to relay network information, communicate and pass situational awareness and messages. The Service Oriented Architecture of S4 enables remote applications to interact with the S4

  8. Smart sensing surveillance system

    Science.gov (United States)

    Hsu, Charles; Chu, Kai-Dee; O'Looney, James; Blake, Michael; Rutar, Colleen

    2010-04-01

    Unattended ground sensor (UGS) networks have been widely used in remote battlefield and other tactical applications over the last few decades due to the advances of the digital signal processing. The UGS network can be applied in a variety of areas including border surveillance, special force operations, perimeter and building protection, target acquisition, situational awareness, and force protection. In this paper, a highly-distributed, fault-tolerant, and energyefficient Smart Sensing Surveillance System (S4) is presented to efficiently provide 24/7 and all weather security operation in a situation management environment. The S4 is composed of a number of distributed nodes to collect, process, and disseminate heterogeneous sensor data. Nearly all S4 nodes have passive sensors to provide rapid omnidirectional detection. In addition, Pan- Tilt- Zoom- (PTZ) Electro-Optics EO/IR cameras are integrated to selected nodes to track the objects and capture associated imagery. These S4 camera-connected nodes will provide applicable advanced on-board digital image processing capabilities to detect and track the specific objects. The imaging detection operations include unattended object detection, human feature and behavior detection, and configurable alert triggers, etc. In the S4, all the nodes are connected with a robust, reconfigurable, LPI/LPD (Low Probability of Intercept/ Low Probability of Detect) wireless mesh network using Ultra-wide band (UWB) RF technology, which can provide an ad-hoc, secure mesh network and capability to relay network information, communicate and pass situational awareness and messages. The S4 utilizes a Service Oriented Architecture such that remote applications can interact with the S4 network and use the specific presentation methods. The S4 capabilities and technologies have great potential for both military and civilian applications, enabling highly effective security support tools for improving surveillance activities in densely crowded

  9. Implementation of a Multimodal Mobile System for Point-of-Sale Surveillance: Lessons Learned From Case Studies in Washington, DC, and New York City

    OpenAIRE

    Cantrell, Jennifer; Ganz, Ollie; Ilakkuvan, Vinu; Tacelosky, Michael; Kreslake, Jennifer; Moon-Howard, Joyce; Aidala, Angela; Vallone, Donna; Anesetti-Rothermel, Andrew; Kirchner, Thomas R

    2015-01-01

    Background In tobacco control and other fields, point-of-sale surveillance of the retail environment is critical for understanding industry marketing of products and informing public health practice. Innovations in mobile technology can improve existing, paper-based surveillance methods, yet few studies describe in detail how to operationalize the use of technology in public health surveillance. Objective The aims of this paper are to share implementation strategies and lessons learned from 2...

  10. SCORPIO - WWER core surveillance system

    International Nuclear Information System (INIS)

    Hornaes, Arne; Bodal, Terje; Sunde, Svein; Zalesky, K.; Lehman, M.; Pecka, M.; Svarny, J.; Krysl, V.; Juzova, Z.; Sedlak, A.; Semmler, M.

    1998-01-01

    The Institut for energiteknikk has developed the core surveillance system SCORPIO, which has two parallel modes of operation: the Core Follow Mode and the Predictive Mode. The main motivation behind the development of SCORPIO is to make a practical tool for reactor operators which can increase the quality and quantity of information presented on core status and dynamic behavior. This can first of all improve plant safety, as undesired core conditions are detected and prevented. Secondly, more flexible and efficient plant operation is made possible. The system has been implemented on western PWRs, but the basic concept is applicable to a wide range of reactors including WWERs. The main differences between WWERs and typical western PWRs with respect to core surveillance requirements are outlined. The development of a WWER version of SCORPIO has been done in co-operation with the Nuclear Research Institute Rez, and industry partners in the Czech Republic. The first system is installed at Dukovany NPP, where the Site Acceptance Test was completed 6. March 1998.(Authors)

  11. SCORPIO - VVER core surveillance system

    International Nuclear Information System (INIS)

    Hornaes, A.; Bodal, T.; Sunde, S.

    1998-01-01

    The Institutt for energiteknikk has developed the core surveillance system SCORPIO, which has two parallel modes of operation: the Core Follow Mode and the Predictive Mode. The main motivation behind the development of SCORPIO is to make a practical tool for reactor operators, which can increase the quality and quantity of information presented on core status and dynamic behavior. This can first of all improve plant safety, as undesired core conditions are detected and prevented. Secondly, more flexible and efficient plant operation is made possible. The system has been implemented on western PWRs, but the basic concept is applicable to a wide range of reactors including VVERs. The main differences between VVERs and typical western PWRs with respect to core surveillance requirements are outlined. The development of a VVER version of SCORPIO has been done in co-operation with the Nuclear Research Institute Rez, and industry partners in the Czech Republic. The first system is installed at Dukovany NPP, where the Site Acceptance Test was completed 6. March 1998.(author)

  12. Privacy Implications of Surveillance Systems

    DEFF Research Database (Denmark)

    Thommesen, Jacob; Andersen, Henning Boje

    2009-01-01

    This paper presents a model for assessing the privacy „cost‟ of a surveillance system. Surveillance systems collect and provide personal information or observations of people by means of surveillance technologies such as databases, video or location tracking. Such systems can be designed for vari......This paper presents a model for assessing the privacy „cost‟ of a surveillance system. Surveillance systems collect and provide personal information or observations of people by means of surveillance technologies such as databases, video or location tracking. Such systems can be designed...... for various purposes, even as a service for those being observed, but in any case they will to some degree invade their privacy. The model provided here can indicate how invasive any particular system may be – and be used to compare the invasiveness of different systems. Applying a functional approach......, the model is established by first considering the social function of privacy in everyday life, which in turn lets us determine which different domains will be considered as private, and finally identify the different types of privacy invasion. This underlying model (function – domain – invasion) then serves...

  13. Youth Risk Behavior Surveillance System

    Science.gov (United States)

    ... Youth Risk Behavior Surveillance System (YRBSS) monitors six types of health-risk behaviors that contribute to the leading causes of death and disability among youth and adults, including— Behaviors that contribute ...

  14. Intelligent video surveillance systems and technology

    CERN Document Server

    Ma, Yunqian

    2009-01-01

    From the streets of London to subway stations in New York City, hundreds of thousands of surveillance cameras ubiquitously collect hundreds of thousands of videos, often running 24/7. How can such vast volumes of video data be stored, analyzed, indexed, and searched? How can advanced video analysis and systems autonomously recognize people and detect targeted activities real-time? Collating and presenting the latest information Intelligent Video Surveillance: Systems and Technology explores these issues, from fundamentals principle to algorithmic design and system implementation.An Integrated

  15. Challenges of implementing an Integrated Disease Surveillance and ...

    African Journals Online (AJOL)

    Tanzania adopted an Integrated Disease Surveillance and Response (IDSR) strategy in 1998 in order to strengthen its infectious disease surveillance system. During that time, the country had 5 separate surveillance systems to monitor infectious disease trends and disease control programmes. The systems included the ...

  16. Environmental health surveillance system; Kankyo hoken surveillance system

    Energy Technology Data Exchange (ETDEWEB)

    Ono, M. [National Inst. for Environmental Studies, Tsukuba (Japan)

    1998-02-01

    The Central Environmental Pollution Prevention Council pointed out the necessity to establish an environmental health surveillance system (hereinafter referred to as System) in its report `on the first type district specified by the Environmental Pollution Caused Health Damages Compensation Act,` issued in 1986. A study team, established in Environment Agency, has been discussing to establish System since 1986. This paper outlines System, and some of the pilot surveillance results. It is not aimed at elucidation of the cause-effect relationships between health and air pollution but at discovery of problems, in which the above relationships in a district population are monitored periodically and continuously from long-term and prospective viewpoints, in order to help take necessary measures in the early stage. System is now collecting the data of the chronic obstructive lung diseases on a nation-wide scale through health examinations of 3-year-old and preschool children and daily air pollution monitoring. 6 refs., 3 figs., 1 tab.

  17. Surveillance data management system

    Science.gov (United States)

    Teague, Ralph

    2002-10-01

    On October 8, 2001, an Executive Order was signed creating the White House Office of Homeland Security. With its formaiton comes focused attention in setting goals and priorities for homeland security. Analysis, preparation, and implementation of strategies will hinge not only on how information is collected and analyzed, but more important, on how it is coordinated and shared. Military installations/facilities, Public safety agencies, airports, federal and local offices, public utilities, harbors, transportation and others critical areas must work either independently or as a team to ensure the safety of our citizens and visitor. In this new era of increased security, the key to interoperation is continuous information exchanged-events must be rapidly identified, reported and responded to by the appropriate agencies. For instance when a threat has been detected the security officers must be immediately alerted and must have access to the type of threat, location, movement, heading, threat size, etc to respond accordingly and the type of support required. This requires instant communications and teamwork with reliable and flexible technology.

  18. Unattended digital video surveillance: A system prototype for EURATOM safeguards

    International Nuclear Information System (INIS)

    Chare, P.; Goerten, J.; Wagner, H.; Rodriguez, C.; Brown, J.E.

    1994-01-01

    Ever increasing capabilities in video and computer technology have changed the face of video surveillance. From yesterday's film and analog video tape-based systems, we now emerge into the digital era with surveillance systems capable of digital image processing, image analysis, decision control logic, and random data access features -- all of which provide greater versatility with the potential for increased effectiveness in video surveillance. Digital systems also offer other advantages such as the ability to ''compress'' data, providing increased storage capacities and the potential for allowing longer surveillance Periods. Remote surveillance and system to system communications are also a benefit that can be derived from digital surveillance systems. All of these features are extremely important in today's climate Of increasing safeguards activity and decreasing budgets -- Los Alamos National Laboratory's Safeguards Systems Group and the EURATOM Safeguards Directorate have teamed to design and implement a period surveillance system that will take advantage of the versatility of digital video for facility surveillance system that will take advantage of the versatility of digital video for facility surveillance and data review. In this Paper we will familiarize you with system components and features and report on progress in developmental areas such as image compression and region of interest processing

  19. Next generation surveillance system (NGSS)

    International Nuclear Information System (INIS)

    Aparo, Massimo

    2006-01-01

    Development of 'functional requirements' for transparency systems may offer a near-term mode of regional cooperation. New requirements under development at the IAEA may provide a foundation for this potential activity. The Next Generation Surveillance System (NGSS) will become the new IAEA remote monitoring system Under new requirements the NGSS would attempt to use more commercial components to reduce cost, increase radiation survivability and further increase reliability. The NGSS must be available in two years due to rapidly approaching obsolescence in the existing DCM family. (author)

  20. Recent advancements on the development of web-based applications for the implementation of seismic analysis and surveillance systems

    Science.gov (United States)

    Friberg, P. A.; Luis, R. S.; Quintiliani, M.; Lisowski, S.; Hunter, S.

    2014-12-01

    Recently, a novel set of modules has been included in the Open Source Earthworm seismic data processing system, supporting the use of web applications. These include the Mole sub-system, for storing relevant event data in a MySQL database (see M. Quintiliani and S. Pintore, SRL, 2013), and an embedded webserver, Moleserv, for serving such data to web clients in QuakeML format. These modules have enabled, for the first time using Earthworm, the use of web applications for seismic data processing. These can greatly simplify the operation and maintenance of seismic data processing centers by having one or more servers providing the relevant data as well as the data processing applications themselves to client machines running arbitrary operating systems.Web applications with secure online web access allow operators to work anywhere, without the often cumbersome and bandwidth hungry use of secure shell or virtual private networks. Furthermore, web applications can seamlessly access third party data repositories to acquire additional information, such as maps. Finally, the usage of HTML email brought the possibility of specialized web applications, to be used in email clients. This is the case of EWHTMLEmail, which produces event notification emails that are in fact simple web applications for plotting relevant seismic data.Providing web services as part of Earthworm has enabled a number of other tools as well. One is ISTI's EZ Earthworm, a web based command and control system for an otherwise command line driven system; another is a waveform web service. The waveform web service serves Earthworm data to additional web clients for plotting, picking, and other web-based processing tools. The current Earthworm waveform web service hosts an advanced plotting capability for providing views of event-based waveforms from a Mole database served by Moleserve.The current trend towards the usage of cloud services supported by web applications is driving improvements in Java

  1. SCORPIO: a framework for core surveillance systems

    International Nuclear Information System (INIS)

    Berg, Oe.; Tsuiki, Makoto

    1999-01-01

    The first version of the core surveillance system SCORPIO was installed at Unit 2, Ringhals, in 1984. It was implemented on Norsk Data mini-computers with a fully graphical user-interface. The main purpose was to provide a practical tool for reactor operators and reactor physicists for on-line monitoring and predictive analysis of core behaviour. A second version of SCORPIO was developed in 1993-1995 and implemented on Unix workstations. In addition to upgrading the system at Ringhals, the system was installed by Duke Power, USA, on 7 reactors. SCORPIO was also installed on the Sizewell B reactor. Recently a new framework has been developed which further enhances the flexibility and capabilities for implementing core surveillance systems in different types of nuclear power plants. Modules can be added and replaced in an easy manner. It allows fast and reliable communication of data between modules based on the Software Bus tool developed by IFE. Further, the Picasso-3 user interface management system supports efficient implementation of different user interfaces. Both Unix and Windows NT platforms are supported. The new framework has been applied in development and installation of a SCORPIO-VVER version for the Dukovany NPP, Czech Republic. Here it was of particular importance to provide a flexible system for integration of modules originating from different companies. Development of a BWR version is now in progress. This means that SCORPIO will be available for all the major reactor types, and synergy is obtained by application of a common framework both with respect to system implementation and maintenance. By using the SCORPIO framework, the development time is reduced and the maintenance work is carried out more efficiently, compared to developing systems with lower-level tools. For instance, the MMI can be developed and tested independently of the physics modules

  2. MATSurv: multisensor air traffic surveillance system

    Science.gov (United States)

    Yeddanapudi, Murali; Bar-Shalom, Yaakov; Pattipati, Krishna R.; Gassner, Richard R.

    1995-09-01

    This paper deals with the design and implementation of MATSurv 1--an experimental Multisensor Air Traffic Surveillance system. The proposed system consists of a Kalman filter based state estimator used in conjunction with a 2D sliding window assignment algorithm. Real data from two FAA radars is used to evaluate the performance of this algorithm. The results indicate that the proposed algorithm provides a superior classification of the measurements into tracks (i.e., the most likely aircraft trajectories) when compared to the aircraft trajectories obtained using the measurement IDs (squawk or IFF code).

  3. First experiences in the implementation of biometric technology to link data from Health and Demographic Surveillance Systems with health facility data

    Directory of Open Access Journals (Sweden)

    Adwoa Serwaa-Bonsu

    2010-02-01

    Full Text Available Background: In developing countries, Health and Demographic Surveillance Systems (HDSSs provide a framework for tracking demographic and health dynamics over time in a defined geographical area. Many HDSSs co-exist with facility-based data sources in the form of Health Management Information Systems (HMIS. Integrating both data sources through reliable record linkage could provide both numerator and denominator populations to estimate disease prevalence and incidence rates in the population and enable determination of accurate health service coverage. Objective: To measure the acceptability and performance of fingerprint biometrics to identify individuals in demographic surveillance populations and those attending health care facilities serving the surveillance populations. Methodology: Two HDSS sites used fingerprint biometrics for patient and/or surveillance population participant identification. The proportion of individuals for whom a fingerprint could be successfully enrolled were characterised in terms of age and sex. Results: Adult (18–65 years fingerprint enrolment rates varied between 94.1% (95% CI 93.6–94.5 for facility-based fingerprint data collection at the Africa Centre site to 96.7% (95% CI 95.9–97.6 for population-based fingerprint data collection at the Agincourt site. Fingerprint enrolment rates in children under 1 year old (Africa Centre site were only 55.1% (95% CI 52.7–57.4. By age 5, child fingerprint enrolment rates were comparable to those of adults. Conclusion: This work demonstrates the feasibility of fingerprint-based individual identification for population-based research in developing countries. Record linkage between demographic surveillance population databases and health care facility data based on biometric identification systems would allow for a more comprehensive evaluation of population health, including the ability to study health service utilisation from a population perspective, rather than the

  4. First experiences in the implementation of biometric technology to link data from Health and Demographic Surveillance Systems with health facility data.

    Science.gov (United States)

    Serwaa-Bonsu, Adwoa; Herbst, Abraham J; Reniers, Georges; Ijaa, Wilfred; Clark, Benjamin; Kabudula, Chodziwadziwa; Sankoh, Osman

    2010-02-24

    In developing countries, Health and Demographic Surveillance Systems (HDSSs) provide a framework for tracking demographic and health dynamics over time in a defined geographical area. Many HDSSs co-exist with facility-based data sources in the form of Health Management Information Systems (HMIS). Integrating both data sources through reliable record linkage could provide both numerator and denominator populations to estimate disease prevalence and incidence rates in the population and enable determination of accurate health service coverage. To measure the acceptability and performance of fingerprint biometrics to identify individuals in demographic surveillance populations and those attending health care facilities serving the surveillance populations. Two HDSS sites used fingerprint biometrics for patient and/or surveillance population participant identification. The proportion of individuals for whom a fingerprint could be successfully enrolled were characterised in terms of age and sex. Adult (18-65 years) fingerprint enrolment rates varied between 94.1% (95% CI 93.6-94.5) for facility-based fingerprint data collection at the Africa Centre site to 96.7% (95% CI 95.9-97.6) for population-based fingerprint data collection at the Agincourt site. Fingerprint enrolment rates in children under 1 year old (Africa Centre site) were only 55.1% (95% CI 52.7-57.4). By age 5, child fingerprint enrolment rates were comparable to those of adults. This work demonstrates the feasibility of fingerprint-based individual identification for population-based research in developing countries. Record linkage between demographic surveillance population databases and health care facility data based on biometric identification systems would allow for a more comprehensive evaluation of population health, including the ability to study health service utilisation from a population perspective, rather than the more restrictive health service perspective.

  5. A Reinforcement Learning Model Equipped with Sensors for Generating Perception Patterns: Implementation of a Simulated Air Navigation System Using ADS-B (Automatic Dependent Surveillance-Broadcast) Technology.

    Science.gov (United States)

    Álvarez de Toledo, Santiago; Anguera, Aurea; Barreiro, José M; Lara, Juan A; Lizcano, David

    2017-01-19

    Over the last few decades, a number of reinforcement learning techniques have emerged, and different reinforcement learning-based applications have proliferated. However, such techniques tend to specialize in a particular field. This is an obstacle to their generalization and extrapolation to other areas. Besides, neither the reward-punishment (r-p) learning process nor the convergence of results is fast and efficient enough. To address these obstacles, this research proposes a general reinforcement learning model. This model is independent of input and output types and based on general bioinspired principles that help to speed up the learning process. The model is composed of a perception module based on sensors whose specific perceptions are mapped as perception patterns. In this manner, similar perceptions (even if perceived at different positions in the environment) are accounted for by the same perception pattern. Additionally, the model includes a procedure that statistically associates perception-action pattern pairs depending on the positive or negative results output by executing the respective action in response to a particular perception during the learning process. To do this, the model is fitted with a mechanism that reacts positively or negatively to particular sensory stimuli in order to rate results. The model is supplemented by an action module that can be configured depending on the maneuverability of each specific agent. The model has been applied in the air navigation domain, a field with strong safety restrictions, which led us to implement a simulated system equipped with the proposed model. Accordingly, the perception sensors were based on Automatic Dependent Surveillance-Broadcast (ADS-B) technology, which is described in this paper. The results were quite satisfactory, and it outperformed traditional methods existing in the literature with respect to learning reliability and efficiency.

  6. The Impact of Law on Syndromic Disease Surveillance Implementation.

    Science.gov (United States)

    Purtle, Jonathan; Field, Robert I; Hipper, Thomas; Nash-Arott, Jillian; Chernak, Esther; Buehler, James W

    Legal environments influence how health information technologies are implemented in public health practice settings. Syndromic disease surveillance (SyS) is a relatively new approach to surveillance that depends heavily on health information technologies to achieve rapid awareness of disease trends. Evidence suggests that legal concerns have impeded the optimization of SyS. To (1) understand the legal environments in which SyS is implemented, (2) determine the perceived legal basis for SyS, and (3) identify perceived legal barriers and facilitators to SyS implementation. Multisite case study in which 35 key informant interviews and 5 focus groups were conducted with 75 SyS stakeholders. Interviews and focus groups were audio recorded, transcribed, and analyzed by 3 coders using thematic content analysis. Legal documents were reviewed. Seven jurisdictions (5 states, 1 county, and 1 city) that were purposively selected on the basis of SyS capacity and legal environment. Health department directors, SyS system administrators, legal counsel, and hospital personnel. Federal (eg, HIPAA) and state (eg, notifiable disease reporting) laws that authorize traditional public health surveillance were perceived as providing a legal basis for SyS. Financial incentives for hospitals to satisfy Meaningful Use regulations have eased concerns about the legality of SyS and increased the number of hospitals reporting SyS data. Legal issues were perceived as barriers to BioSense 2.0 (the federal SyS program) participation but were surmountable. Major legal reforms are not needed to promote more widespread use of SyS. The current legal environment is perceived by health department and hospital officials as providing a firm basis for SyS practice. This is a shift from how law was perceived when SyS adoption began and has policy implications because it indicates that major legal reforms are not needed to promote more widespread use of the technology. Beyond SyS, our study suggests that

  7. Video auto stitching in multicamera surveillance system

    Science.gov (United States)

    He, Bin; Zhao, Gang; Liu, Qifang; Li, Yangyang

    2012-01-01

    This paper concerns the problem of video stitching automatically in a multi-camera surveillance system. Previous approaches have used multiple calibrated cameras for video mosaic in large scale monitoring application. In this work, we formulate video stitching as a multi-image registration and blending problem, and not all cameras are needed to be calibrated except a few selected master cameras. SURF is used to find matched pairs of image key points from different cameras, and then camera pose is estimated and refined. Homography matrix is employed to calculate overlapping pixels and finally implement boundary resample algorithm to blend images. The result of simulation demonstrates the efficiency of our method.

  8. Mobile phone-based syndromic surveillance system, Papua New Guinea.

    Science.gov (United States)

    Rosewell, Alexander; Ropa, Berry; Randall, Heather; Dagina, Rosheila; Hurim, Samuel; Bieb, Sibauk; Datta, Siddhartha; Ramamurthy, Sundar; Mola, Glen; Zwi, Anthony B; Ray, Pradeep; MacIntyre, C Raina

    2013-11-01

    The health care system in Papua New Guinea is fragile, and surveillance systems infrequently meet international standards. To strengthen outbreak identification, health authorities piloted a mobile phone-based syndromic surveillance system and used established frameworks to evaluate whether the system was meeting objectives. Stakeholder experience was investigated by using standardized questionnaires and focus groups. Nine sites reported data that included 7 outbreaks and 92 cases of acute watery diarrhea. The new system was more timely (2.4 vs. 84 days), complete (70% vs. 40%), and sensitive (95% vs. 26%) than existing systems. The system was simple, stable, useful, and acceptable; however, feedback and subnational involvement were weak. A simple syndromic surveillance system implemented in a fragile state enabled more timely, complete, and sensitive data reporting for disease risk assessment. Feedback and provincial involvement require improvement. Use of mobile phone technology might improve the timeliness and efficiency of public health surveillance.

  9. Mobile Phone–based Syndromic Surveillance System, Papua New Guinea

    Science.gov (United States)

    Ropa, Berry; Randall, Heather; Dagina, Rosheila; Hurim, Samuel; Bieb, Sibauk; Datta, Siddhartha; Ramamurthy, Sundar; Mola, Glen; Zwi, Anthony B.; Ray, Pradeep; MacIntyre, C. Raina

    2013-01-01

    The health care system in Papua New Guinea is fragile, and surveillance systems infrequently meet international standards. To strengthen outbreak identification, health authorities piloted a mobile phone–based syndromic surveillance system and used established frameworks to evaluate whether the system was meeting objectives. Stakeholder experience was investigated by using standardized questionnaires and focus groups. Nine sites reported data that included 7 outbreaks and 92 cases of acute watery diarrhea. The new system was more timely (2.4 vs. 84 days), complete (70% vs. 40%), and sensitive (95% vs. 26%) than existing systems. The system was simple, stable, useful, and acceptable; however, feedback and subnational involvement were weak. A simple syndromic surveillance system implemented in a fragile state enabled more timely, complete, and sensitive data reporting for disease risk assessment. Feedback and provincial involvement require improvement. Use of mobile phone technology might improve the timeliness and efficiency of public health surveillance. PMID:24188144

  10. Unattended video surveillance systems for international safeguards

    International Nuclear Information System (INIS)

    Johnson, C.S.

    1979-01-01

    The use of unattended video surveillance systems places some unique requirements on the systems and their hardware. The systems have the traditional requirements of video imaging, video storage, and video playback but also have some special requirements such as tamper safing. The technology available to meet these requirements and how it is being applied to unattended video surveillance systems are discussed in this paper

  11. Post-tensioning system surveillance program

    International Nuclear Information System (INIS)

    Drew, G.E.

    1979-01-01

    Nuclear power plant containment structure post-tensioning system tendon surveillance program is described in detail. Data collected over three yearly post-tensioning system Surveillance Programs is presented and evaluated to correlate anticipated stress losses with actual losses. In addition corrosion protected system performance is analyzed

  12. CDC Behavioral Risk Factor Surveillance System (BRFSS)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Behavioral Risk Factor Surveillance System (BRFSS) is a state-based system of health surveys that collects information on health risk behaviors, preventive...

  13. Remote container monitoring and surveillance systems

    International Nuclear Information System (INIS)

    Resnik, W.M.; Kadner, S.P.

    1995-01-01

    Aquila Technologies Group is developing a monitoring and surveillance system to monitor containers of nuclear materials. The system will both visually and physically monitor the containers. The system is based on the combination of Aquila's Gemini All-Digital Surveillance System and on Aquila's AssetLAN trademark asset tracking technology. This paper discusses the Gemini Digital Surveillance system as well as AssetLAN technology. The Gemini architecture with emphasis on anti-tamper security features is also described. The importance of all-digital surveillance versus other surveillance methods is also discussed. AssetLAN trademark technology is described, emphasizing the ability to continually track containers (as assets) by location utilizing touch memory technology. Touch memory technology provides unique container identification, as well as the ability to store and retrieve digital information on the container. This information may relate to container maintenance, inspection schedules, and other information. Finally, this paper describes the combination of the Gemini system with AssetLAN technology, yielding a self contained, container monitoring and area/container surveillance system. Secure container fixture design considerations are discussed. Basic surveillance review functions are also discussed

  14. Reliability demonstration of imaging surveillance systems

    International Nuclear Information System (INIS)

    Sheridan, T.F.; Henderson, J.T.; MacDiarmid, P.R.

    1979-01-01

    Security surveillance systems which employ closed circuit television are being deployed with increasing frequency for the protection of property and other valuable assets. A need exists to demonstrate the reliability of such systems before their installation to assure that the deployed systems will operate when needed with only the scheduled amount of maintenance and support costs. An approach to the reliability demonstration of imaging surveillance systems which employ closed circuit television is described. Failure definitions based on industry television standards and imaging alarm assessment criteria for surveillance systems are discussed. Test methods which allow 24 hour a day operation without the need for numerous test scenarios, test personnel and elaborate test facilities are presented. Existing reliability demonstration standards are shown to apply which obviate the need for elaborate statistical tests. The demonstration methods employed are shown to have applications in other types of imaging surveillance systems besides closed circuit television

  15. Implementing a quality assurance system in the Laboratory of Environmental Radiological Surveillance from the Center of Protection and Hygiene of Radiation

    International Nuclear Information System (INIS)

    Prendes Alosno, M.; Fernandes Gomez, I.M.; Marrero Garcia, M.

    1998-01-01

    This work aimed to design and implement a system for quality assurance. The same describes working experiences, the organization of the registry system, the training and certification of the staff, checking, maintenance and calibration of equipment as well as internal auditing process made

  16. Youth Risk Behavior Surveillance System (YRBSS)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Youth Risk Behavior Surveillance System (YRBSS) monitors 6 types of health-risk behaviors that contribute to the leading causes of death and disability among...

  17. Science and engineering intelligent surveillance systems

    CERN Document Server

    Huihuan, Qian; Xu, Yangsheng

    2011-01-01

    As shortcomings such as high labor costs make intelligent surveillance systems more desirable, this practical book focuses on detecting abnormal behavior based on learning and the analysis of dangerous crowd behavior based on texture and optical flow.

  18. The multi-camera optical surveillance system (MOS)

    International Nuclear Information System (INIS)

    Otto, P.; Wagner, H.; Richter, B.; Gaertner, K.J.; Laszlo, G.; Neumann, G.

    1991-01-01

    The transition from film camera to video surveillance systems, in particular the implementation of high capacity multi-camera video systems, results in a large increase in the amount of recorded scenes. Consequently, there is a substantial increase in the manpower requirements for review. Moreover, modern microprocessor controlled equipment facilitates the collection of additional data associated with each scene. Both the scene and the annotated information have to be evaluated by the inspector. The design of video surveillance systems for safeguards necessarily has to account for both appropriate recording and reviewing techniques. An aspect of principal importance is that the video information is stored on tape. Under the German Support Programme to the Agency a technical concept has been developed which aims at optimizing the capabilities of a multi-camera optical surveillance (MOS) system including the reviewing technique. This concept is presented in the following paper including a discussion of reviewing and reliability

  19. Laser surveillance system for spent fuel

    International Nuclear Information System (INIS)

    Fiarman, S.; Zucker, M.S.; Bieber, A.M. Jr.

    1980-01-01

    A laser surveillance system installed at spent fuel storage pools (SFSP's) will provide the safeguard inspector with specific knowledge of spent fuel movement that cannot be obtained with current surveillance systems. The laser system will allow for the division of the pool's spent fuel inventory into two populations - those assemblies which have been moved and those which haven't - which is essential for maximizing the efficiency and effectiveness of the inspection effort. We have designed, constructed, and tested a full size laser system operating in air and have used an array of 6 zircaloy BWR tubes to simulate an assembly. The reflective signal from the zircaloy rods is a strong function of position of the assembly, but in all cases is easily discernable from the reference scan of the background with no assembly. A design for a SFSP laser surveillance system incorporating laser ranging is discussed. 10 figures

  20. MO-F-16A-06: Implementation of a Radiation Exposure Monitoring System for Surveillance of Multi-Modality Radiation Dose Data

    International Nuclear Information System (INIS)

    Stewart, B; Kanal, K; Dickinson, R; Zamora, D

    2014-01-01

    Purpose: We have implemented a commercially available Radiation Exposure Monitoring System (REMS) to enhance the processes of radiation dose data collection, analysis and alerting developed over the past decade at our sites of practice. REMS allows for consolidation of multiple radiation dose information sources and quicker alerting than previously developed processes. Methods: Thirty-nine x-ray producing imaging modalities were interfaced with the REMS: thirteen computed tomography scanners, sixteen angiography/interventional systems, nine digital radiography systems and one mammography system. A number of methodologies were used to provide dose data to the REMS: Modality Performed Procedure Step (MPPS) messages, DICOM Radiation Dose Structured Reports (RDSR), and DICOM header information. Once interfaced, the dosimetry information from each device underwent validation (first 15–20 exams) before release for viewing by end-users: physicians, medical physicists, technologists and administrators. Results: Before REMS, our diagnostic physics group pulled dosimetry data from seven disparate databases throughout the radiology, radiation oncology, cardiology, electrophysiology, anesthesiology/pain management and vascular surgery departments at two major medical centers and four associated outpatient clinics. With the REMS implementation, we now have one authoritative source of dose information for alerting, longitudinal analysis, dashboard/graphics generation and benchmarking. REMS provides immediate automatic dose alerts utilizing thresholds calculated through daily statistical analysis. This has streamlined our Closing the Loop process for estimated skin exposures in excess of our institutional specific substantial radiation dose level which relied on technologist notification of the diagnostic physics group and daily report from the radiology information system (RIS). REMS also automatically calculates the CT size-specific dose estimate (SSDE) as well as provides

  1. MO-F-16A-06: Implementation of a Radiation Exposure Monitoring System for Surveillance of Multi-Modality Radiation Dose Data

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, B; Kanal, K; Dickinson, R; Zamora, D [University Washington, Seattle, WA (United States)

    2014-06-15

    Purpose: We have implemented a commercially available Radiation Exposure Monitoring System (REMS) to enhance the processes of radiation dose data collection, analysis and alerting developed over the past decade at our sites of practice. REMS allows for consolidation of multiple radiation dose information sources and quicker alerting than previously developed processes. Methods: Thirty-nine x-ray producing imaging modalities were interfaced with the REMS: thirteen computed tomography scanners, sixteen angiography/interventional systems, nine digital radiography systems and one mammography system. A number of methodologies were used to provide dose data to the REMS: Modality Performed Procedure Step (MPPS) messages, DICOM Radiation Dose Structured Reports (RDSR), and DICOM header information. Once interfaced, the dosimetry information from each device underwent validation (first 15–20 exams) before release for viewing by end-users: physicians, medical physicists, technologists and administrators. Results: Before REMS, our diagnostic physics group pulled dosimetry data from seven disparate databases throughout the radiology, radiation oncology, cardiology, electrophysiology, anesthesiology/pain management and vascular surgery departments at two major medical centers and four associated outpatient clinics. With the REMS implementation, we now have one authoritative source of dose information for alerting, longitudinal analysis, dashboard/graphics generation and benchmarking. REMS provides immediate automatic dose alerts utilizing thresholds calculated through daily statistical analysis. This has streamlined our Closing the Loop process for estimated skin exposures in excess of our institutional specific substantial radiation dose level which relied on technologist notification of the diagnostic physics group and daily report from the radiology information system (RIS). REMS also automatically calculates the CT size-specific dose estimate (SSDE) as well as provides

  2. A comprehensive review on intelligent surveillance systems

    Directory of Open Access Journals (Sweden)

    Sutrisno Warsono Ibrahim

    2016-05-01

    Full Text Available Intelligent surveillance system (ISS has received growing attention due to the increasing demand on security and safety. ISS is able to automatically analyze image, video, audio or other type of surveillance data without or with limited human intervention. The recent developments in sensor devices, computer vision, and machine learning have an important role in enabling such intelligent system. This paper aims to provide general overview of intelligent surveillance system and discuss some possible sensor modalities and their fusion scenarios such as visible camera (CCTV, infrared camera, thermal camera and radar. This paper also discusses main processing steps in ISS: background-foreground segmentation, object detection and classification, tracking, and behavioral analysis.

  3. Was the French clinical surveillance system of bovine brucellosis influenced by the occurrence and surveillance of other abortive diseases?

    Science.gov (United States)

    Bronner, Anne; Morignat, Eric; Touratier, Anne; Gache, Kristel; Sala, Carole; Calavas, Didier

    2015-03-01

    The bovine brucellosis clinical surveillance system implemented in France aims to detect early any case of bovine brucellosis, a disease of which the country has been declared free since 2005. It relies on the mandatory notification of every bovine abortion. Following the spread of the Schmallenberg virus (SBV) in France in 2012 and 2013, and the implementation in 2012 of a clinical surveillance programme of Q fever based on abortion notifications in ten pilot départements, our objective was to study whether these two events influenced the brucellosis clinical surveillance system. The proportion of notifying farmers was analyzed over each semester from June 1, 2009 to June 30, 2013 according to the size and production type of herds, SBV status of départements and the implementation of the Q fever surveillance. Our analysis showed a slight increase in the proportion of notifying farmers as départements became infected by SBV, and after the implementation of Q fever surveillance (during the first semester of 2013). These variations might be explained by an increase in abortion occurrence (congenital deformities in newborns, due to SBV) and/or by an increase in farmers' and veterinarians' awareness (due to the spread of SBV and the implementation of the Q fever surveillance). These results highlight the difficulties in interpreting variations in the proportion of notifying farmers as a consequence of an increase in abortion occurrence. As bovine abortion surveillance can play an important role in the early warning for several diseases, there is a need to explore other ways to monitor abortions in cattle, such as syndromic surveillance using the dates of artificial insemination or calving data. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Surveillance system for nuclear power plants

    International Nuclear Information System (INIS)

    Mizeracki, M.T.

    1981-01-01

    This paper describes an integrated surveillance system for nuclear power plant application. The author explores an expanded role for closed circuit television, with remotely located cameras and infrared scanners as the basic elements. The video system, integrated with voice communication, can enhance the safe and efficient operation of the plant, by improving the operator's knowledge of plant conditions. 7 refs

  5. Multimodal surveillance sensors, algorithms, and systems

    CERN Document Server

    Zhu, Zhigang

    2007-01-01

    From front-end sensors to systems and environmental issues, this practical resource guides you through the many facets of multimodal surveillance. The book examines thermal, vibration, video, and audio sensors in a broad context of civilian and military applications. This cutting-edge volume provides an in-depth treatment of data fusion algorithms that takes you to the core of multimodal surveillance, biometrics, and sentient computing. The book discusses such people and activity topics as tracking people and vehicles and identifying individuals by their speech.Systems designers benefit from d

  6. Information Systems to Support Surveillance for Malaria Elimination

    Science.gov (United States)

    Ohrt, Colin; Roberts, Kathryn W.; Sturrock, Hugh J. W.; Wegbreit, Jennifer; Lee, Bruce Y.; Gosling, Roly D.

    2015-01-01

    Robust and responsive surveillance systems are critical for malaria elimination. The ideal information system that supports malaria elimination includes: rapid and complete case reporting, incorporation of related data, such as census or health survey information, central data storage and management, automated and expert data analysis, and customized outputs and feedback that lead to timely and targeted responses. Spatial information enhances such a system, ensuring cases are tracked and mapped over time. Data sharing and coordination across borders are vital and new technologies can improve data speed, accuracy, and quality. Parts of this ideal information system exist and are in use, but have yet to be linked together coherently. Malaria elimination programs should support the implementation and refinement of information systems to support surveillance and response and ensure political and financial commitment to maintain the systems and the human resources needed to run them. National malaria programs should strive to improve the access and utility of these information systems and establish cross-border data sharing mechanisms through the use of standard indicators for malaria surveillance. Ultimately, investment in the information technologies that support a timely and targeted surveillance and response system is essential for malaria elimination. PMID:26013378

  7. Information systems to support surveillance for malaria elimination.

    Science.gov (United States)

    Ohrt, Colin; Roberts, Kathryn W; Sturrock, Hugh J W; Wegbreit, Jennifer; Lee, Bruce Y; Gosling, Roly D

    2015-07-01

    Robust and responsive surveillance systems are critical for malaria elimination. The ideal information system that supports malaria elimination includes: rapid and complete case reporting, incorporation of related data, such as census or health survey information, central data storage and management, automated and expert data analysis, and customized outputs and feedback that lead to timely and targeted responses. Spatial information enhances such a system, ensuring cases are tracked and mapped over time. Data sharing and coordination across borders are vital and new technologies can improve data speed, accuracy, and quality. Parts of this ideal information system exist and are in use, but have yet to be linked together coherently. Malaria elimination programs should support the implementation and refinement of information systems to support surveillance and response and ensure political and financial commitment to maintain the systems and the human resources needed to run them. National malaria programs should strive to improve the access and utility of these information systems and establish cross-border data sharing mechanisms through the use of standard indicators for malaria surveillance. Ultimately, investment in the information technologies that support a timely and targeted surveillance and response system is essential for malaria elimination. © The American Society of Tropical Medicine and Hygiene.

  8. Inexpensive remote video surveillance system with microcomputer and solar cells

    International Nuclear Information System (INIS)

    Guevara Betancourt, Edder

    2013-01-01

    A low-cost prototype is developed with a RPI plate for remote video surveillance. Additionally, the theoretical basis to provide energy independence have developed through solar cells and a battery bank. Some existing commercial monitoring systems are studied and analyzed, components such as: cameras, communication devices (WiFi and 3G), free software packages for video surveillance, control mechanisms and theory remote photovoltaic systems. A number of steps are developed to implement the module and install, configure and test each of the elements of hardware and software that make up the module, exploring the feasibility of providing intelligence to the system using the software chosen. Events that have been generated by motion detection have been simple, intuitive way to view, archive and extract. The implementation of the module by a microcomputer video surveillance and motion detection software (Zoneminder) has been an option for a lot of potential; as the platform for monitoring and recording data has provided all the tools to make a robust and secure surveillance. (author) [es

  9. Next Generation Space Surveillance System-of-Systems

    Science.gov (United States)

    McShane, B.

    2014-09-01

    International economic and military dependence on space assets is pervasive and ever-growing in an environment that is now congested, contested, and competitive. There are a number of natural and man-made risks that need to be monitored and characterized to protect and preserve the space environment and the assets within it. Unfortunately, today's space surveillance network (SSN) has gaps in coverage, is not resilient, and has a growing number of objects that get lost. Risks can be efficiently and effectively mitigated, gaps closed, resiliency improved, and performance increased within a next generation space surveillance network implemented as a system-of-systems with modern information architectures and analytic techniques. This also includes consideration for the newest SSN sensors (e.g. Space Fence) which are born Net-Centric out-of-the-box and able to seamlessly interface with the JSpOC Mission System, global information grid, and future unanticipated users. Significant opportunity exists to integrate legacy, traditional, and non-traditional sensors into a larger space system-of-systems (including command and control centers) for multiple clients through low cost sustainment, modification, and modernization efforts. Clients include operations centers (e.g. JSpOC, USSTRATCOM, CANSPOC), Intelligence centers (e.g. NASIC), space surveillance sensor sites (e.g. AMOS, GEODSS), international governments (e.g. Germany, UK), space agencies (e.g. NASA), and academic institutions. Each has differing priorities, networks, data needs, timeliness, security, accuracy requirements and formats. Enabling processes and technologies include: Standardized and type accredited methods for secure connections to multiple networks, machine-to-machine interfaces for near real-time data sharing and tip-and-queue activities, common data models for analytical processing across multiple radar and optical sensor types, an efficient way to automatically translate between differing client and

  10. System specification for the integrated monitoring and surveillance system

    International Nuclear Information System (INIS)

    1997-09-01

    This System Specification establishes the requirements for the Plutonium Focus Area (PFA) Integrated Monitoring and Surveillance System (IMSS). In this document, ''Integrated Monitoring and Surveillance System'' is used to describe the concept of integrated sensors, computers, personnel, and systems that perform the functions of sensing conditions, acquiring data, monitoring environmental safety and health, controlling and accounting for materials, monitoring material stability, monitoring container integrity, transferring data, and analyzing, reporting, and storing data. This concept encompasses systems (e.g. sensors, personnel, databases, etc.) that are already in place at the sites but may require modifications or additions to meet all identified surveillance requirements. The purpose of this System Specification is to provide Department of Energy (DOE) sites that store plutonium materials with a consolidation of all known requirements for the storage and surveillance of 3013 packages of stabilized plutonium metals and oxides. This compilation may be used (1) as a baseline for surveillance system design specifications where 3013 packages of stabilized plutonium metals and oxides will be stored and monitored; (2) as a checklist for evaluating existing surveillance systems to ensure that all requirements are met for the storage and surveillance of 3013 packages of stabilized plutonium metals and oxides; and (3) as a baseline for preparing procurement specifications tailored for site specific storage and surveillance of 3013 packages of stabilized plutonium metals and oxides

  11. Surveyor mobile surveillance system for hazardous environments

    International Nuclear Information System (INIS)

    Silverman, E.B.; Simmons, R.K.; Kniazewycz, B.G.; Darvish, A.R.; Irving, T.L.

    1987-01-01

    A successful program was recently conducted to test and evaluate a commercial-ready, wireless, remotely operated surveillance system for use in nuclear power plants. This evaluation of the Surveyor mobile surveillance system took place at Niagara Mohawk Power Corporation's Nine Mile Point Nuclear Power Station. The remotely operated vehicle measures radiation, temperature and relative humidity and provides optical inspection capability. The vehicle is readily maneuvered in 36-inch wide passageways and labyrinth entries and can climb stairs, negotiating 180-degree turns on stair landings. The system consists of a supervisory control station and a rugged, remotely-operated, battery-powered vehicle. The surveyor system is specifically designed to decrease personnel radiation exposure by supplementing the functions of an auxiliary operator or wealth physics technician to perform periodic component inspections inside particular areas within a nuclear power plant

  12. Laser surveillance system for spent fuel

    International Nuclear Information System (INIS)

    Fiarman, S.; Zucker, M.S.; Bieber, A.M. Jr.

    1980-01-01

    A laser surveillance system installed at spent fuel storage pools will provide the safeguard inspector with specific knowledge of spent fuel movement that cannot be obtained with current surveillance systems. The laser system will allow for the division of the pool's spent fuel inventory into two populations - those assemblies which have been moved and those which haven't - which is essential for maximizing the efficiency and effectiveness of the inspection effort. We have designed, constructed, and tested a laser system and have used it with a simulated BWR assembly. The reflected signal from the zircaloy rods depends on the position of the assembly, but in all cases is easily discernable from the reference scan of background with no assembly

  13. Evaluation of HIV Surveillance System in Rivers State, Nigeria ...

    African Journals Online (AJOL)

    Sony Computer (Iby)

    HIV surveillance system generates information for timely and appropriate ..... active type of surveillance.14 Nonetheless, it requires training, supervision and motivation ... very effectively.14 The introduction of reward-system could be included.

  14. ALGORITHM OF PLACEMENT OF VIDEO SURVEILLANCE CAMERAS AND ITS SOFTWARE IMPLEMENTATION

    Directory of Open Access Journals (Sweden)

    Loktev Alexey Alexeevich

    2012-10-01

    Full Text Available Comprehensive distributed safety, control, and monitoring systems applied by companies and organizations of different ownership structure play a substantial role in the present-day society. Video surveillance elements that ensure image processing and decision making in automated or automatic modes are the essential components of new systems. This paper covers the modeling of video surveillance systems installed in buildings, and the algorithm, or pattern, of video camera placement with due account for nearly all characteristics of buildings, detection and recognition facilities, and cameras themselves. This algorithm will be subsequently implemented as a user application. The project contemplates a comprehensive approach to the automatic placement of cameras that take account of their mutual positioning and compatibility of tasks. The project objective is to develop the principal elements of the algorithm of recognition of a moving object to be detected by several cameras. The image obtained by different cameras will be processed. Parameters of motion are to be identified to develop a table of possible options of routes. The implementation of the recognition algorithm represents an independent research project to be covered by a different article. This project consists in the assessment of the degree of complexity of an algorithm of camera placement designated for identification of cases of inaccurate algorithm implementation, as well as in the formulation of supplementary requirements and input data by means of intercrossing sectors covered by neighbouring cameras. The project also contemplates identification of potential problems in the course of development of a physical security and monitoring system at the stage of the project design development and testing. The camera placement algorithm has been implemented as a software application that has already been pilot tested on buildings and inside premises that have irregular dimensions. The

  15. Surveillance systems for intermodal transportation

    Science.gov (United States)

    Jakovlev, Sergej; Voznak, Miroslav; Andziulis, Arunas

    2015-05-01

    Intermodal container monitoring is considered a major security issue in many major logistic companies and countries worldwide. Current representation of the problem, we face today, originated in 2002, right after the 9/11 attacks. Then, a new worldwide Container Security Initiative (CSI, 2002) was considered that shaped the perception of the transportation operations. Now more than 80 larger ports all over the world contribute to its further development and integration into everyday transportation operations and improve the regulations for the developing regions. Although, these new improvements allow us to feel safer and secure, constant management of transportation operations has become a very difficult problem for conventional data analysis methods and information systems. The paper deals with a proposal of a whole new concept for the improvement of the Containers Security Initiative (CSI) by virtually connecting safety, security processes and systems. A conceptual middleware approach with deployable intelligent agent modules is proposed to be used with possible scenarios and a testbed is used to test the solution. Middleware examples are visually programmed using National Instruments LabView software packages and Wireless sensor network hardware modules. An experimental software is used to evaluate he solution. This research is a contribution to the intermodal transportation and is intended to be used as a means or the development of intelligent transport systems.

  16. Evaluation of HIV Surveillance System in Rivers State, Nigeria ...

    African Journals Online (AJOL)

    Background: Rivers State has been reported to have the highest HIV prevalence of all the thirty-six states in Nigeria. HIV surveillance system generates information for timely and appropriate public health action. Evaluation of the surveillance system is vital in ensuring that the purpose of the surveillance system is being met.

  17. Web-based infectious disease surveillance systems and public health perspectives: a systematic review

    Directory of Open Access Journals (Sweden)

    Jihye Choi

    2016-12-01

    needed, web-based surveillance systems have evolved to complement traditional national surveillance systems. This review highlights ways in which the strengths of existing systems can be maintained and weaknesses alleviated to implement optimal web surveillance systems.

  18. SCM: a practical tool to implement hospital-based syndromic surveillance.

    Science.gov (United States)

    Ye, Chuchu; Li, Zhongjie; Fu, Yifei; Lan, Yajia; Zhu, Weiping; Zhou, Dinglun; Zhang, Honglong; Lai, Shengjie; Buckeridge, David L; Sun, Qiao; Yang, Weizhong

    2016-06-18

    Syndromic surveillance has been widely used for the early warning of infectious disease outbreaks, especially in mass gatherings, but the collection of electronic data on symptoms in hospitals is one of the fundamental challenges that must be overcome during operating a syndromic surveillance system. The objective of our study is to describe and evaluate the implementation of a symptom-clicking-module (SCM) as a part of the enhanced hospital-based syndromic surveillance during the 41st World Exposition in Shanghai, China, 2010. The SCM, including 25 targeted symptoms, was embedded in the sentinels' Hospital Information Systems (HIS). The clinicians used SCM to record these information of all the visiting patients, and data were collated and transmitted automatically in daily batches. The symptoms were categorized into seven targeted syndromes using pre-defined criteria, and statistical algorithms were applied to detect temporal aberrations in the data series. SCM was deployed successfully in each sentinel hospital and was operated during the 184-day surveillance period. A total of 1,730,797 patient encounters were recorded by SCM, and 6.1 % (105,352 visits) met the criteria of the seven targeted syndromes. Acute respiratory and gastrointestinal syndromes were reported most frequently, accounted for 92.1 % of reports in all syndromes, and the aggregated time-series presented an obvious day-of-week variation over the study period. In total, 191 aberration signals were triggered, and none of them were identified as outbreaks after verification and field investigation. SCM has acted as a practical tool for recording symptoms in the hospital-based enhanced syndromic surveillance system during the 41st World Exposition in Shanghai, in the context of without a preexisting electronic tool to collect syndromic data in the HIS of the sentinel hospitals.

  19. The Argentine remote monitoring and surveillance system

    International Nuclear Information System (INIS)

    Bonino, A.; Roca, J.L.; Perez, A.; Pizarro, L.; Krimer, M.; Teira, R.; Higa, Z.; Saettone, S.; Monzon, J.; Moroni, D.

    1996-01-01

    The Scientific and Technical Support Department of the Argentine National Board of Nuclear Regulation (ENREN) has developed a Remote Monitoring and Surveillance System (RMSS) that provides a media to verify state of variables related to the monitoring and surveillance activities of nuclear facilities, mainly safeguard applications. RMSS includes a variety of on site installed sensors, an authenticated radiofrequency communication link, a receiver processing unit, an active vision set and a user friendly personal computer interface to collect, view and store pertinent histories of events. A real time data base allows consulting, maintenance, updating and checking activities. RMSS could be integrated into a LAN or WAN via modem for use in a remote operation scheme. In this paper a description of the RMSS is provided. Also, an overview of the RMSS operation at one facility under safeguards belonging to the National Commission of Atomic Energy (CNEA) is presented. Results and conclusions of the system associated with this facility are given. (author). 37 figs

  20. The Argentine remote monitoring and surveillance system

    Energy Technology Data Exchange (ETDEWEB)

    Bonino, A; Roca, J L; Perez, A; Pizarro, L; Krimer, M; Teira, R; Higa, Z; Saettone, S; Monzon, J; Moroni, D [Ente Nacional Regulador Nuclear, Buenos Aires (Argentina). Dept. Apoyo Cientifico y Tecnico

    1997-12-31

    The Scientific and Technical Support Department of the Argentine National Board of Nuclear Regulation (ENREN) has developed a Remote Monitoring and Surveillance System (RMSS) that provides a media to verify state of variables related to the monitoring and surveillance activities of nuclear facilities, mainly safeguard applications. RMSS includes a variety of on site installed sensors, an authenticated radiofrequency communication link, a receiver processing unit, an active vision set and a user friendly personal computer interface to collect, view and store pertinent histories of events. A real time data base allows consulting, maintenance, updating and checking activities. RMSS could be integrated into a LAN or WAN via modem for use in a remote operation scheme. In this paper a description of the RMSS is provided. Also, an overview of the RMSS operation at one facility under safeguards belonging to the National Commission of Atomic Energy (CNEA) is presented. Results and conclusions of the system associated with this facility are given. (author). 37 figs.

  1. Expert system for surveillance and diagnosis of breach fuel elements

    Science.gov (United States)

    Gross, Kenny C.

    1989-01-01

    An apparatus and method are disclosed for surveillance and diagnosis of breached fuel elements in a nuclear reactor. A delayed neutron monitoring system provides output signals indicating the delayed neutron activity and age and the equivalent recoil areas of a breached fuel element. Sensors are used to provide outputs indicating the status of each component of the delayed neutron monitoring system. Detectors also generate output signals indicating the reactor power level and the primary coolant flow rate of the reactor. The outputs from the detectors and sensors are interfaced with an artificial intelligence-based knowledge system which implements predetermined logic and generates output signals indicating the operability of the reactor.

  2. Expert system for surveillance and diagnosis of breach fuel elements

    International Nuclear Information System (INIS)

    Gross, K.C.

    1989-01-01

    An apparatus and method are disclosed for surveillance and diagnosis of breached fuel elements in a nuclear reactor. A delayed neutron monitoring system provides output signals indicating the delayed neutron activity and age and the equivalent recoil areas of a breached fuel element. Sensors are used to provide outputs indicating the status of each component of the delayed neutron monitoring system. Detectors also generate output signals indicating the reactor power level and the primary coolant flow rate of the reactor. The outputs from the detectors and sensors are interfaced with an artificial intelligence-based knowledge system which implements predetermined logic and generates output signals indicating the operability of the reactor

  3. Laser surveillance systems for fuel storage pools

    International Nuclear Information System (INIS)

    Boeck, H.

    1985-06-01

    A Laser Surveillance System (LASSY) as a new safeguards device has been developed under the IAEA research contract No. 3458/RB at the Atominstitut Wien using earlier results by S. Fiarman. This system is designed to act as a sheet of light covering spent fuel assemblies in spent fuel storage pools. When movement of assemblies takes place, LASSY detects and locates the position of the movement in the pool and when interrogated, presents a list of pool positions and times of movement to the safeguards inspector. A complete prototype system was developed and built. Full scale tests showed the principal working capabilities of a LASSY underwater

  4. Recording and surveillance systems for periodontal diseases

    DEFF Research Database (Denmark)

    Beltrán-Aguilar, Eugenio D; Eke, Paul I; Thornton-Evans, Gina

    2012-01-01

    This paper describes tools used to measure periodontal diseases and the integration of these tools into surveillance systems. Tools to measure periodontal diseases at the surveillance level have focussed on current manifestations of disease (e.g. gingival inflammation) or disease sequelae (e.......g. periodontal pocket depth or loss of attachment). All tools reviewed in this paper were developed based on the state of the science of the pathophysiology of periodontal disease at the time of their design and the need to provide valid and reliable measurements of the presence and severity of periodontal...... diseases. Therefore, some of these tools are no longer valid. Others, such as loss of periodontal attachment, are the current de-facto tools but demand many resources to undertake periodical assessment of the periodontal health of populations. Less complex tools such as the Community Periodontal Index...

  5. Implementing Student Information Systems

    Science.gov (United States)

    Sullivan, Laurie; Porter, Rebecca

    2006-01-01

    Implementing an enterprise resource planning system is a complex undertaking. Careful planning, management, communication, and staffing can make the difference between a successful and unsuccessful implementation. (Contains 3 tables.)

  6. An integrated national mortality surveillance system for death registration and mortality surveillance, China.

    Science.gov (United States)

    Liu, Shiwei; Wu, Xiaoling; Lopez, Alan D; Wang, Lijun; Cai, Yue; Page, Andrew; Yin, Peng; Liu, Yunning; Li, Yichong; Liu, Jiangmei; You, Jinling; Zhou, Maigeng

    2016-01-01

    In China, sample-based mortality surveillance systems, such as the Chinese Center for Disease Control and Prevention's disease surveillance points system and the Ministry of Health's vital registration system, have been used for decades to provide nationally representative data on health status for health-care decision-making and performance evaluation. However, neither system provided representative mortality and cause-of-death data at the provincial level to inform regional health service needs and policy priorities. Moreover, the systems overlapped to a considerable extent, thereby entailing a duplication of effort. In 2013, the Chinese Government combined these two systems into an integrated national mortality surveillance system to provide a provincially representative picture of total and cause-specific mortality and to accelerate the development of a comprehensive vital registration and mortality surveillance system for the whole country. This new system increased the surveillance population from 6 to 24% of the Chinese population. The number of surveillance points, each of which covered a district or county, increased from 161 to 605. To ensure representativeness at the provincial level, the 605 surveillance points were selected to cover China's 31 provinces using an iterative method involving multistage stratification that took into account the sociodemographic characteristics of the population. This paper describes the development and operation of the new national mortality surveillance system, which is expected to yield representative provincial estimates of mortality in China for the first time.

  7. Violence Against Children Surveys (VACS): towards a global surveillance system.

    Science.gov (United States)

    Chiang, Laura F; Kress, Howard; Sumner, Steven A; Gleckel, Jessie; Kawemama, Philbert; Gordon, Rebecca N

    2016-04-01

    To describe the Violence Against Children Surveys (VACS). The survey is a national, household survey that systematically measures the prevalence, nature and consequences of sexual, physical and emotional violence against children. This report provides information about the history, implementation, ethical protections, utility, results, limitations, and future directions of the VACS work. The study has been implemented in 11 countries in Africa, Asia and the Caribbean, providing each of these countries with baseline data and momentum to address violence against children as a public health and human rights priority. These data are novel in each country, and VACS is well poised to contribute to an existing surveillance system or be used as the basis of a periodic surveillance system. Without ongoing surveillance to assess prevalence and the impact of policy, prevention and response programming, violence will likely continue to be overlooked as the linchpin public health crisis that it is, globally and in individual countries. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  8. Surveillance Monitoring Management for General Care Units: Strategy, Design, and Implementation.

    Science.gov (United States)

    McGrath, Susan P; Taenzer, Andreas H; Karon, Nancy; Blike, George

    2016-07-01

    The growing number of monitoring devices, combined with suboptimal patient monitoring and alarm management strategies, has increased "alarm fatigue," which have led to serious consequences. Most reported alarm man- agement approaches have focused on the critical care setting. Since 2007 Dartmouth-Hitchcock (Lebanon, New Hamp- shire) has developed a generalizable and effective design, implementation, and performance evaluation approach to alarm systems for continuous monitoring in general care settings (that is, patient surveillance monitoring). In late 2007, a patient surveillance monitoring system was piloted on the basis of a structured design and implementation approach in a 36-bed orthopedics unit. Beginning in early 2009, it was expanded to cover more than 200 inpatient beds in all medicine and surgical units, except for psychiatry and labor and delivery. Improvements in clinical outcomes (reduction of unplanned transfers by 50% and reduction of rescue events by more than 60% in 2008) and approximately two alarms per patient per 12-hour nursing shift in the original pilot unit have been sustained across most D-H general care units in spite of increasing patient acuity and unit occupancy. Sample analysis of pager notifications indicates that more than 85% of all alarm conditions are resolved within 30 seconds and that more than 99% are resolved before escalation is triggered. The D-H surveillance monitoring system employs several important, generalizable features to manage alarms in a general care setting: alarm delays, static thresholds set appropriately for the prevalence of events in this setting, directed alarm annunciation, and policy-driven customization of thresholds to allow clinicians to respond to needs of individual patients. The systematic approach to design, implementation, and performance management has been key to the success of the system.

  9. Strengthening Injury Surveillance System in Iran

    Directory of Open Access Journals (Sweden)

    Motevalian Seyed Abbas

    2012-02-01

    Full Text Available 【Abstract】Objective: To strengthen the current Injury Surveillance System (IS System in order to better monitor injury conditions, improve protection ways and promote safety. Methods: At first we carried out a study to evaluate the frameworks of IS System in the developed countries. Then all the available documents from World Health Organization, Eastern Mediterranean Regional Organization, as well as Minister of Health and Medical Education concerning Iran were reviewed. Later a national stakeholder抯 consultation was held to collect opinions and views. A national workshop was also intended for provincial representatives from 41 universities to identify the barriers and limitations of the existing program and further to strengthen injury surveillance. Results: The evaluation of the current IS System revealed many problems, mainly presented as lack of accurate pre- and post-hospital death registry, need of precise injury data registry in outpatient medical centers, incomplete injury data registry in hospitals and lack of accuracy in definition of variables in injury registry. The five main characteristics of current IS System including flexibility, acceptability, simplicity, usefulness and timeliness were evaluated as moderate by experts. Conclusions: Major revisions must be considered in the current IS System in Iran. The following elements should be added to the questionnaire: identifier, manner of arrival to the hospital, situation of the injured patient, consumption of alcohol and opioids, other involved participants in the accident, intention, severity and site of injury, side effects of surgery and medication, as well as one month follow-up results. Data should be collected from 10% of all hospitals in Iran and analyzed every 3 months. Simultaneously data should be online to be retrieved by researches. Key words: Wounds and injuries; Population surveillance; Registries; Iran

  10. Cost analysis of an integrated vaccine-preventable disease surveillance system in Costa Rica.

    Science.gov (United States)

    Toscano, C M; Vijayaraghavan, M; Salazar-Bolaños, H M; Bolaños-Acuña, H M; Ruiz-González, A I; Barrantes-Solis, T; Fernández-Vargas, I; Panero, M S; de Oliveira, L H; Hyde, T B

    2013-07-02

    Following World Health Organization recommendations set forth in the Global Framework for Immunization Monitoring and Surveillance, Costa Rica in 2009 became the first country to implement integrated vaccine-preventable disease (iVPD) surveillance, with support from the U.S. Centers for Disease Control and Prevention (CDC) and the Pan American Health Organization (PAHO). As surveillance for diseases prevented by new vaccines is integrated into existing surveillance systems, these systems could cost more than routine surveillance for VPDs targeted by the Expanded Program on Immunization. We estimate the costs associated with establishing and subsequently operating the iVPD surveillance system at a pilot site in Costa Rica. We retrospectively collected data on costs incurred by the institutions supporting iVPD surveillance during the preparatory (January 2007 through August 2009) and implementation (September 2009 through August 2010) phases of the iVPD surveillance project in Costa Rica. These data were used to estimate costs for personnel, meetings, infrastructure, office equipment and supplies, transportation, and laboratory facilities. Costs incurred by each of the collaborating institutions were also estimated. During the preparatory phase, the estimated total cost was 128,000 U.S. dollars (US$), including 64% for personnel costs. The preparatory phase was supported by CDC and PAHO. The estimated cost for 1 year of implementation was US$ 420,000, including 58% for personnel costs, 28% for laboratory costs, and 14% for meeting, infrastructure, office, and transportation costs combined. The national reference laboratory and the PAHO Costa Rica office incurred 64% of total costs, and other local institutions supporting iVPD surveillance incurred the remaining 36%. Countries planning to implement iVPD surveillance will require adequate investments in human resources, laboratories, data management, reporting, and investigation. Our findings will be valuable for

  11. Logistical and safeguards aspects related to the introduction and implementation of video surveillance equipment by EURATOM

    International Nuclear Information System (INIS)

    Chare, P.J.; Wagner, H.G.; Otto, P.; Schenkel, R.

    1987-01-01

    With the growing availability of reliable video equipment for surveillance applications in safeguards and the disappearance of the Super 8 mm cameras, there will be a period of transition from film camera to video surveillance, a process which started two years ago. This gradual transition, as the film cameras come to the end of their useful lives, will afford the safeguards authorities the opportunity to examine in detail the logistical and procedural changes necessary. This paper examines, on the basis of existing video equipment in use or under development, the differences and problems to be encountered in the approach to surveillance. These problems include tamper resistance of signal transmission, on site and headquarters review, preventative maintenance, reliability, repair, and overall performance evaluation. In addition the advantages and flexibility offered by the introduction of video, such as on site review and increased memory capacity, are also discussed. The paper also considers the overall costs and manpower required by EURATOM for the implementation of the video systems as compared to the existing twin Minolta film camera system to ensure the most efficient use of manpower and equipment

  12. Functional requirements for core surveillance systems

    International Nuclear Information System (INIS)

    Andersson, T.

    2000-01-01

    Operating experience at Ringhals-2 has demonstrated the feasibility of a mixed core surveillance system comprised of fixed in-core detectors combined with the original movable detector system. A small number of fixed in-core detectors provide continuous measurement of the thermal margins while the movable detectors are used mainly at start-up to verify the expected power distribution. Reactor noise diagnostics and neural networks can further improve the monitoring system. The reliability of the movable detector system can be improved by mechanical simplification. Wear and maintenance costs are lowered if the required flux-mapping frequency is reduced. Improved computer codes make the measurement uncertainties less dependent on the number of instrumented positions. A mixed system requires new types of technical specifications. (author)

  13. Canadian CANDU plant data systems for technical surveillance and analysis

    International Nuclear Information System (INIS)

    Deverno, M.; Pothier, H.; Xian, C.; Grosbois, J. De; Bosnich, M.

    1996-01-01

    Plant data systems are emerging as a critical plant support system technology. In particular, plant-wide Historical Data Systems (HDS) are pivotal to the successful implementation of technical surveillance and analysis programs supporting plant operations, maintenance, safety, and licensing activities. In partnership with Canadian CANDU utility and design organizations, AECL has conducted a review of current Canadian CANDU HDS approaches with emphasis on understanding the existing functionality and uses of plant historical data systems, their future needs and benefits. The results is a vision of a plant-wide HDS providing seamless access to both near real-time and historical data, user tool-kits for data visualization and analysis, and data management of the large volume of data acquired during the life of a plant. The successful implementation of the HDS vision will lead to higher capability and capacity factors while minimizing Operations, Maintenance, and Administration (OM and A) costs. (author). 5 refs, 3 figs

  14. Canadian CANDU plant data systems for technical surveillance and analysis

    Energy Technology Data Exchange (ETDEWEB)

    Deverno, M; Pothier, H; Xian, C [Atomic Energy of Canada Ltd., Control Centre Technology Branch, Fredericton, NB (Canada); Grosbois, J De; Bosnich, M [Atomic Energy of Canada Ltd., Control Centre Technology Branch, Chalk River, ON (Canada). Chalk River Labs.

    1997-12-31

    Plant data systems are emerging as a critical plant support system technology. In particular, plant-wide Historical Data Systems (HDS) are pivotal to the successful implementation of technical surveillance and analysis programs supporting plant operations, maintenance, safety, and licensing activities. In partnership with Canadian CANDU utility and design organizations, AECL has conducted a review of current Canadian CANDU HDS approaches with emphasis on understanding the existing functionality and uses of plant historical data systems, their future needs and benefits. The results is a vision of a plant-wide HDS providing seamless access to both near real-time and historical data, user tool-kits for data visualization and analysis, and data management of the large volume of data acquired during the life of a plant. The successful implementation of the HDS vision will lead to higher capability and capacity factors while minimizing Operations, Maintenance, and Administration (OM and A) costs. (author). 5 refs, 3 figs.

  15. Real-time wideband holographic surveillance system

    Science.gov (United States)

    Sheen, D.M.; Collins, H.D.; Hall, T.E.; McMakin, D.L.; Gribble, R.P.; Severtsen, R.H.; Prince, J.M.; Reid, L.D.

    1996-09-17

    A wideband holographic surveillance system including a transceiver for generating a plurality of electromagnetic waves; antenna for transmitting the electromagnetic waves toward a target at a plurality of predetermined positions in space; the transceiver also receiving and converting electromagnetic waves reflected from the target to electrical signals at a plurality of predetermined positions in space; a computer for processing the electrical signals to obtain signals corresponding to a holographic reconstruction of the target; and a display for displaying the processed information to determine nature of the target. The computer has instructions to apply a three dimensional backward wave algorithm. 28 figs.

  16. Is the HIV sentinel surveillance system adequate in China? Findings from an evaluation of the national HIV sentinel surveillance system

    Directory of Open Access Journals (Sweden)

    Marc Bulterys

    2012-11-01

    Full Text Available Background: An external evaluation was conducted to assess the performance of the national HIV sentinel surveillance system (HSS, identify operational challenges at national and local levels and provide recommendations for improvement.Methods: The United States Centers for Disease Control and Prevention’s (CDC Updated Guidelines for Evaluating Public Health Surveillance Systems were followed to assess the key attributes of HSS. Comprehensive assessment activities were conducted, including: using a detailed checklist to review surveillance guidelines, protocols and relevant documents; conducting self-administered, anonymous surveys with 286 local China CDC staff; and carrying out field observations in 32 sentinel sites in four provinces.Results: China has built an extensive HSS with 1888 sentinel sites to monitor HIV epidemic trends by population groups over time. The strengths of HSS lie in its flexibility, simplicity, usefulness and increase in coverage in locations and populations. With its rapid expansion in 2010, HSS faces challenges in maintaining acceptability, timeliness, data quality, representativeness and sustainability.Recommendations: Implementation of the national guidelines should be standardized by strengthening training, monitoring and supervision of all staff involved, including community-based organizations. National surveillance guidelines need to be revised to strengthen data quality and representativeness, particularly to include specific instructions on HIV testing result provision, collection of identifying information, sample size and sampling methods particularly for men who have sex with men (MSM, collection of refusal information, and data interpretation. Sustainability of China’s HSS could be strengthened by applying locally tailored surveillance strategies, strengthening coordination and cooperation among government agencies and ensuring financial and human resources.

  17. Automated intelligent video surveillance system for ships

    Science.gov (United States)

    Wei, Hai; Nguyen, Hieu; Ramu, Prakash; Raju, Chaitanya; Liu, Xiaoqing; Yadegar, Jacob

    2009-05-01

    To protect naval and commercial ships from attack by terrorists and pirates, it is important to have automatic surveillance systems able to detect, identify, track and alert the crew on small watercrafts that might pursue malicious intentions, while ruling out non-threat entities. Radar systems have limitations on the minimum detectable range and lack high-level classification power. In this paper, we present an innovative Automated Intelligent Video Surveillance System for Ships (AIVS3) as a vision-based solution for ship security. Capitalizing on advanced computer vision algorithms and practical machine learning methodologies, the developed AIVS3 is not only capable of efficiently and robustly detecting, classifying, and tracking various maritime targets, but also able to fuse heterogeneous target information to interpret scene activities, associate targets with levels of threat, and issue the corresponding alerts/recommendations to the man-in- the-loop (MITL). AIVS3 has been tested in various maritime scenarios and shown accurate and effective threat detection performance. By reducing the reliance on human eyes to monitor cluttered scenes, AIVS3 will save the manpower while increasing the accuracy in detection and identification of asymmetric attacks for ship protection.

  18. Sustainable Monitoring and Surveillance Systems to Improve HIV Programs: Review.

    Science.gov (United States)

    Low-Beer, Daniel; Mahy, Mary; Renaud, Francoise; Calleja, Txema

    2018-04-24

    HIV programs have provided a major impetus for investments in surveillance data, with 5-10% of HIV program budgets recommended to support data. However there are questions concerning the sustainability of these investments. The Sustainable Development Goals have consolidated health into one goal and communicable diseases into one target (Target 3.3). Sustainable Development Goals now introduce targets focused specifically on data (Targets 17.18 and 17.19). Data are seen as one of the three systemic issues (in Goal 17) for implementing Sustainable Development Goals, alongside policies and partnerships. This paper reviews the surveillance priorities in the context of the Sustainable Development Goals and highlights the shift from periodic measurement towards sustainable disaggregated, real-time, case, and patient data, which are used routinely to improve programs. Finally, the key directions in developing person-centered monitoring systems are assessed with country examples. The directions contribute to the Sustainable Development Goal focus on people-centered development applied to data. ©Daniel Low-Beer, Mary Mahy, Francoise Renaud, Txema Calleja. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 24.04.2018.

  19. ACP Facility Safety Surveillance System Installation

    International Nuclear Information System (INIS)

    You, Gil Sung; Kook, D. H.; Choung, W. M.; Ku, J. H.; Cho, I. J.; You, G. S.; Kwon, K. C.; Lee, W. K.; Lee, E. P.

    2006-10-01

    The Advanced spent fuel Conditioning Process is under development for effective management of spent fuel by converting UO 2 into U-metal. For demonstration of this process, α-γ type new hotcell was built in the IMEF basement. All facilities which treat radioactive materials must manage CCTV system which is under control of Health Physics department. Three main points (including hotcell rear door area) have each camera, but operators who are in charge of facility management need to check the safety of the facility immediately through the network in his office. This needs introduce additional network cameras installation and this new surveillance system is expected to update the whole safety control ability with existing system

  20. Evaluation of a radioactive aerosol surveillance system

    International Nuclear Information System (INIS)

    Scripsick, R.C.; Stafford, R.G.; Beckman, R.J.; Tillery, M.I.; Romero, P.O.

    Measurements of the dilution of air contaminants between worker breathing zone and area air samplers were made by releasing a test aerosol in a workroom equipped with an aerosol surveillance system. The data were used to evaluate performance, and suggest improvements in design of the workroom's alarming air monitor system. It was found that a breathing zone concentration of 960 times the maximum permissible concentration in air (MPC/sub a/) for a half-hour was required to trigger alarms of the existing monitoring system under some release conditions. Alternative air monitor placement, suggested from dilution measurements, would reduce this average triggering concentration to 354 MPC/sub a/. Deployment of additional air monitors could further reduce the average triggering concentration to 241 MPC/sub a/. The relation between number of monitors and triggering concentration was studied. No significant decrease in average triggering concentration was noted for arrays containing greater than five monitors

  1. Surveillance

    DEFF Research Database (Denmark)

    Albrechtslund, Anders; Coeckelbergh, Mark; Matzner, Tobias

    Studying surveillance involves raising questions about the very nature of concepts such as information, technology, identity, space and power. Besides the maybe all too obvious ethical issues often discussed with regard to surveillance, there are several other angles and approaches that we should...... like to encourage. Therefore, our panel will focus on the philosophical, yet non-ethical issues of surveillance in order to stimulate an intense debate with the audience on the ethical implications of our enquiries. We also hope to provide a broader and deeper understanding of surveillance....

  2. Strengthening Injury Surveillance System in Iran

    Institute of Scientific and Technical Information of China (English)

    Seyed Abbas Motevalian; Mashyaneh Haddadi; Hesam Akbari; Reza Khorramirouz; Soheil Saadat; Arash Tehrani; Vafa Rahimi-Movaghar

    2011-01-01

    Objective:To strengthen the current Injury Surveillance System (IS System) in order to better monitor injury conditions,improve protection ways and promote safety.Methods:At first we carried out a study to evaluate the frameworks of IS System in the developed countries.Then all the available documents from World Health OrganizationEastern Mediterranean Regional Organization,as well as Minister of Health and Medical Education concerning Iran were reviewed.Later a national stakeholder's consultation was held to collect opinions and views.A national workshop was also intended for provincial representatives from 41 universities to identify the barriers and limitations of the existing program and further to strengthen injury surveillance.Results:The evaluation of the current IS System revealed many problems,mainly presented as lack of accurate pre- and post-hospital death registry,need of precise injury data registry in outpatient medical centers,incomplete injury data registry in hospitals and lack of accuracy in definition of variables in injury registry.The five main characteristics of current IS System including flexibility,acceptability,simplicity,usefulness and timeliness were evaluated as moderate by experts.Contusions:Major revisions must be considered in the current IS System in Iran.The following elements should be added to the questionnaire:identifier,manner of arrival to the hospital,situation of the injured patient,consumption of alcohol and opioids,other involved participants in the accident,intention,severity and site of injury,side effects of surgery and medication,as well as one month follow-up results.Data should be collected from 10% of all hospitals in Iran and analyzed every 3 months.Simultaneously data should be online to be retrieved by researches.

  3. Illness and injury in athletes during the competition period at the London 2012 Paralympic Games: development and implementation of a web-based surveillance system (WEB-IISS) for team medical staff.

    Science.gov (United States)

    Derman, Wayne; Schwellnus, Martin; Jordaan, Esme; Blauwet, Cheri A; Emery, Carolyn; Pit-Grosheide, Pia; Marques, Norma-Angelica Patino; Martinez-Ferrer, Oriol; Stomphorst, Jaap; Van de Vliet, Peter; Webborn, Nick; Willick, Stuart E

    2013-05-01

    In this study we describe (1) the implementation of a novel web-based injury and illness surveillance system (WEB-IISS) for use by a team of physicians at multisport events and (2) the incidence and characteristics of injuries and illness in athletes during the London 2012 Paralympic Games. Overall, 3565 athletes from 160 of the 164 participating countries were followed daily over a 14-day period, consisting of a precompetition period (3 days), and a competition period (11 days) (49 910 athlete-days). Daily injury and illness data were obtained from teams with their own medical support (78 teams, 3329 athletes) via the WEB-IISS, and without their own medical support through the London Organising Committee of the Olympic Games and Paralympic Games database (82 teams and 236 athletes). There were no differences between incidence rates (IR) of injury and illness, or between the precompetition and competition periods. The IR of injury during the competition period was 12.1/1000 athlete-days, with an incidence proportion (IP) of 11.6% (95% CI 11.0% to 13.3%). Upper limb injuries (35%), particularly of the shoulder (17%) were most common. The IR of illness during the competition period was 12.8/1000 athlete-days (95% CI 12.18 to 1421), with an IP of 10.2%. The IP was highest in the respiratory system (27.4%), skin (18.3%) and the gastrointestinal (14.5%) systems. During the competition period, the IR and IP of illness and injury at the Games were similar and comparable to the observed rates in other elite competitions. In Paralympic athletes, the IP of upper limb injuries is higher than that of lower limb injuries and non-respiratory illnesses are more common.

  4. Optimizing the response to surveillance alerts in automated surveillance systems.

    Science.gov (United States)

    Izadi, Masoumeh; Buckeridge, David L

    2011-02-28

    Although much research effort has been directed toward refining algorithms for disease outbreak alerting, considerably less attention has been given to the response to alerts generated from statistical detection algorithms. Given the inherent inaccuracy in alerting, it is imperative to develop methods that help public health personnel identify optimal policies in response to alerts. This study evaluates the application of dynamic decision making models to the problem of responding to outbreak detection methods, using anthrax surveillance as an example. Adaptive optimization through approximate dynamic programming is used to generate a policy for decision making following outbreak detection. We investigate the degree to which the model can tolerate noise theoretically, in order to keep near optimal behavior. We also evaluate the policy from our model empirically and compare it with current approaches in routine public health practice for investigating alerts. Timeliness of outbreak confirmation and total costs associated with the decisions made are used as performance measures. Using our approach, on average, 80 per cent of outbreaks were confirmed prior to the fifth day of post-attack with considerably less cost compared to response strategies currently in use. Experimental results are also provided to illustrate the robustness of the adaptive optimization approach and to show the realization of the derived error bounds in practice. Copyright © 2011 John Wiley & Sons, Ltd.

  5. Second Generation of HIV Surveillance System: A Pattern for Iran

    OpenAIRE

    Nematollahi, M; Khalesi, N; Moghaddasi, H; Askarian, M

    2012-01-01

    Background For the purpose of minimizing the HIV/AIDS epidemic effects, one of the programs is the promotion of scientific methods and setting of the suitable surveillance systems. The present research was conducted to design the HIV/AIDS surveillance system in Iran applying WHO recommendations and the experience of some countries. Methods In 2009, based on the country's requirements, the HIV/AIDS surveillance system was proposed and designed for Iran. The Delphi technique was utilized to fin...

  6. Low-cost panoramic infrared surveillance system

    Science.gov (United States)

    Kecskes, Ian; Engel, Ezra; Wolfe, Christopher M.; Thomson, George

    2017-05-01

    A nighttime surveillance concept consisting of a single surface omnidirectional mirror assembly and an uncooled Vanadium Oxide (VOx) longwave infrared (LWIR) camera has been developed. This configuration provides a continuous field of view spanning 360° in azimuth and more than 110° in elevation. Both the camera and the mirror are readily available, off-the-shelf, inexpensive products. The mirror assembly is marketed for use in the visible spectrum and requires only minor modifications to function in the LWIR spectrum. The compactness and portability of this optical package offers significant advantages over many existing infrared surveillance systems. The developed system was evaluated on its ability to detect moving, human-sized heat sources at ranges between 10 m and 70 m. Raw camera images captured by the system are converted from rectangular coordinates in the camera focal plane to polar coordinates and then unwrapped into the users azimuth and elevation system. Digital background subtraction and color mapping are applied to the images to increase the users ability to extract moving items from background clutter. A second optical system consisting of a commercially available 50 mm f/1.2 ATHERM lens and a second LWIR camera is used to examine the details of objects of interest identified using the panoramic imager. A description of the components of the proof of concept is given, followed by a presentation of raw images taken by the panoramic LWIR imager. A description of the method by which these images are analyzed is given, along with a presentation of these results side-by-side with the output of the 50 mm LWIR imager and a panoramic visible light imager. Finally, a discussion of the concept and its future development are given.

  7. Automated Safety Incident Surveillance and Tracking System (ASISTS)

    Data.gov (United States)

    Department of Veterans Affairs — The Automated Safety Incident Surveillance and Tracking System (ASISTS) is a repository of Veterans Health Administration (VHA) employee accident data. Many types of...

  8. Traffic Flow Wide-Area Surveillance system

    Energy Technology Data Exchange (ETDEWEB)

    Allgood, G.O.; Ferrell, R.K.; Kercel, S.W.; Abston, R.A.

    1994-09-01

    Traffic management can be thought of as a stochastic queuing process where the serving time at one of its control points is dynamically linked to the global traffic pattern, which is, in turn, dynamically linked to the control point. For this closed-loop system to be effective, the traffic management system must sense and interpret a large spatial projection of data originating from multiple sensor suites. This concept is the basis for the development of a Traffic Flow Wide-Area Surveillance (TFWAS) system. This paper presents the results of a study by Oak Ridge National Laboratory to define the operational specifications and characteristics, to determine the constraints, and to examine the state of technology of a TFWAS system in terms of traffic management and control. In doing so, the functions and attributes of a TFWAS system are mapped into an operational structure consistent with the Intelligent Vehicle Highway System (IVHS) concept and the existing highway infrastructure. This mapping includes identifying candidate sensor suites and establishing criteria, requirements, and performance measures by which these systems can be graded in their ability and practicality to meet the operational requirements of a TFWAS system. In light of this, issues such as system integration, applicable technologies, impact on traffic management and control, and public acceptance are addressed.

  9. Traffic flow wide-area surveillance system

    Science.gov (United States)

    Allgood, Glenn O.; Ferrell, Regina K.; Kercel, Stephen W.; Abston, Ruth A.

    1995-01-01

    Traffic management can be thought of as a stochastic queuing process where the serving time at one of its control points is dynamically linked to the global traffic pattern, which is, in turn, dynamically linked to the control point. For this closed-loop system to be effective, the traffic management system must sense and interpret a large spatial projection of data originating from multiple sensor suites. This concept is the basis for the development of a traffic flow wide-area surveillance (TFWAS) system. This paper presents the results of a study by Oak Ridge National Laboratory to define the operational specifications and characteristics, to determine the constraints, and to examine the state of technology of a TFWAS system in terms of traffic management and control. In doing so, the functions and attributes of a TFWAS system are mapped into an operational structure consistent with the Intelligent Vehicle Highway System (IVHS) concept and the existing highway infrastructure. This mapping includes identifying candidate sensor suites and establishing criteria, requirements, and performance measures by which these systems can be graded in their ability and practicality to meet the operational requirements of a TFWAS system. In light of this, issues such as system integration, applicable technologies, impact on traffic management and control, and public acceptance are addressed.

  10. Validation of an electronic surveillance system for acute lung injury.

    Science.gov (United States)

    Herasevich, Vitaly; Yilmaz, Murat; Khan, Hasrat; Hubmayr, Rolf D; Gajic, Ognjen

    2009-06-01

    Early detection of acute lung injury (ALI) is essential for timely implementation of evidence-based therapies and enrollment into clinical trials. We aimed to determine the accuracy of computerized syndrome surveillance for detection of ALI in hospitalized patients and compare it with routine clinical assessment. Using a near-real time copy of the electronic medical records, we developed and validated a custom ALI electronic alert (ALI "sniffer") based on the European-American Consensus Conference Definition and compared its performance against provider-derived documentation. A total of 3,795 consecutive critically ill patients admitted to nine multidisciplinary intensive care units (ICUs) of a tertiary care teaching institution were included. ALI developed in 325 patients and was recognized by bedside clinicians in only 86 (26.5%). Under-recognition of ALI was associated with not implementing protective mechanical ventilation (median tidal volumes of 9.2 vs. 8.0 ml/kg predicted body weight, P sniffer" demonstrated excellent sensitivity of 96% (95% CI 94-98) and moderate specificity of 89% (95% CI 88-90) with a positive predictive value ranging from 24% (95% CI 13-40) in the heart-lung transplant ICU to 64% (95% CI 55-71) in the medical ICU. The computerized surveillance system accurately identifies critically ill patients who develop ALI syndrome. Since the lack of ALI recognition is a barrier to the timely implementation of best practices and enrollment into research studies, computerized syndrome surveillance could be a useful tool to enhance patient safety and clinical research.

  11. Survey of surveillance systems and select prevention activities for hepatitis B and C, European Union/European Economic Area, 2009.

    Science.gov (United States)

    Duffell, E F; van de Laar, M J

    2015-04-02

    Hepatitis B and C viral infections are leading causes of hepatic cirrhosis and cancer. The incidence and prevalence of both hepatitis B and C varies across European countries. European wide surveillance data help to understand the dynamic epidemiology of hepatitis B and C, which is important for the implementation and effectiveness of prevention and control activities.Comparison of surveillance data between countries in Europe is hampered by the differences in national healthcare and reporting systems. This report presents the results of a survey in 2009 which was undertaken to collect baseline information on surveillance systems and core prevention programmes for hepatitis B and C in individual European Union/ European Economic Area countries. The results provide key information to aid the interpretation of surveillance data, and while indicating heterogeneity in national surveillance systems and programmes, they highlight the potential of these systems. This resource has supported the implementation of a standardised European enhanced surveillance programme.

  12. 32 CFR 637.20 - Security surveillance systems.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Security surveillance systems. 637.20 Section 637... ENFORCEMENT AND CRIMINAL INVESTIGATIONS MILITARY POLICE INVESTIGATION Investigations § 637.20 Security surveillance systems. Closed circuit video recording systems, to include those with an audio capability, may be...

  13. Implementing maternal death surveillance and response: a review of lessons from country case studies.

    Science.gov (United States)

    Smith, Helen; Ameh, Charles; Roos, Natalie; Mathai, Matthews; Broek, Nynke van den

    2017-07-17

    Maternal Death Surveillance and Response (MDSR) implementation is monitored globally, but not much is known about what works well, where and why in scaling up. We reviewed a series of country case studies in order to determine whether and to what extent these countries have implemented the four essential components of MDSR and identify lessons for improving implementation. A secondary analysis of ten case studies from countries at different stages of MDSR implementation, using a policy analysis framework to draw out lessons learnt and opportunities for improvement. We identify the consistent drivers of success in countries with well-established systems for MDSR, and common barriers in countries were Maternal Death Review (MDR) systems have been less successful. MDR is accepted and ongoing at subnational level in many countries, but it is not adequately institutionalised and the shift from facility based MDR to continuous MDSR that informs the wider health system still needs to be made. Our secondary analysis of country experiences highlights the need for a) social and team processes at facility level, for example the existence of a 'no shame, no blame' culture, and the ability to reflect on practice and manage change as a team for recommendations to be acted upon, b) health system inputs including adequate funding and reliable health information systems to enable identification and analysis of cases c) national level coordination of dissemination, and monitoring implementation of recommendations at all levels and d) mandatory notification of maternal deaths (and enforcement of this) and a professional requirement to participate in MDRs. Case studies from countries with established MDSR systems can provide valuable guidance on ways to set up the processes and overcome some of the barriers; but the challenge, as with many health system interventions, is to find a way to provide catalytic assistance and strengthen capacity for MDSR such that this becomes embedded in

  14. European Surveillance System on Contact Allergies (ESSCA)

    DEFF Research Database (Denmark)

    Uter, W; Amario-Hita, J C; Balato, A

    2017-01-01

    BACKGROUND: Contact allergy is a common condition and can severely interfere with daily life or professional activities. Due to changes in exposures, such as introduction of new substances, new products or formulations and regulatory intervention, the spectrum of contact sensitization changes....... OBJECTIVE: To evaluate the current spectrum of contact allergy to allergens present in the European baseline series (EBS) across Europe. METHODS: Retrospective analysis of data collected by the European Surveillance System on Contact Allergies (ESSCA, www.essca-dc.org) in consecutively patch-tested patients......, 2013/14, in 46 departments in 12 European countries. RESULTS: Altogether, 31 689 patients were included in the analysis. Compared to a similar analysis in 2004, the prevalence of contact allergy to methylisothiazolinone went up to around 20% in several departments. In comparison, contact allergy...

  15. Containment and surveillance systems for international safeguards

    International Nuclear Information System (INIS)

    Ney, J.F.

    1978-01-01

    Important criteria in measuring the effectiveness of IAEA safeguards include timeliness of detection of diversion, timeliness of reporting such detections, and confidence in determining the amount of material diverted. Optimum use of IAEA inspectors, combined with adequate instrumentation, can provide a practical means for achieving these criteria. System studies are being carried out for different types of facilities that may come under IAEA safeguards to determine the proper balance between inspector's efforts and the use of safeguards instrumentation. A description of a typical study is presented. Based on the results of these studies, the program undertaken to develop those containment and surveillance subsystems for which the technical feasibility and operational acceptability need to be established is described

  16. SCORPION II persistent surveillance system update

    Science.gov (United States)

    Coster, Michael; Chambers, Jon

    2010-04-01

    This paper updates the improvements and benefits demonstrated in the next generation Northrop Grumman SCORPION II family of persistent surveillance and target recognition systems produced by the Xetron Campus in Cincinnati, Ohio. SCORPION II reduces the size, weight, and cost of all SCORPION components in a flexible, field programmable system that is easier to conceal and enables integration of over fifty different Unattended Ground Sensor (UGS) and camera types from a variety of manufacturers, with a modular approach to supporting multiple Line of Sight (LOS) and Beyond Line of Sight (BLOS) communications interfaces. Since 1998 Northrop Grumman has been integrating best in class sensors with its proven universal modular Gateway to provide encrypted data exfiltration to Common Operational Picture (COP) systems and remote sensor command and control. In addition to feeding COP systems, SCORPION and SCORPION II data can be directly processed using a common sensor status graphical user interface (GUI) that allows for viewing and analysis of images and sensor data from up to seven hundred SCORPION system gateways on single or multiple displays. This GUI enables a large amount of sensor data and imagery to be used for actionable intelligence as well as remote sensor command and control by a minimum number of analysts.

  17. Electronic Integrated Disease Surveillance System and Pathogen Asset Control System

    Directory of Open Access Journals (Sweden)

    Tom G. Wahl

    2012-06-01

    Full Text Available Electronic Integrated Disease Surveillance System (EIDSS has been used to strengthen and support monitoring and prevention of dangerous diseases within One Health concept by integrating veterinary and human surveillance, passive and active approaches, case-based records including disease-specific clinical data based on standardised case definitions and aggregated data, laboratory data including sample tracking linked to each case and event with test results and epidemiological investigations. Information was collected and shared in secure way by different means: through the distributed nodes which are continuously synchronised amongst each other, through the web service, through the handheld devices. Electronic Integrated Disease Surveillance System provided near real time information flow that has been then disseminated to the appropriate organisations in a timely manner. It has been used for comprehensive analysis and visualisation capabilities including real time mapping of case events as these unfold enhancing decision making. Electronic Integrated Disease Surveillance System facilitated countries to comply with the IHR 2005 requirements through a data transfer module reporting diseases electronically to the World Health Organisation (WHO data center as well as establish authorised data exchange with other electronic system using Open Architecture approach. Pathogen Asset Control System (PACS has been used for accounting, management and control of biological agent stocks. Information on samples and strains of any kind throughout their entire lifecycle has been tracked in a comprehensive and flexible solution PACS. Both systems have been used in a combination and individually. Electronic Integrated Disease Surveillance System and PACS are currently deployed in the Republics of Kazakhstan, Georgia and Azerbaijan as a part of the Cooperative Biological Engagement Program (CBEP sponsored by the US Defense Threat Reduction Agency (DTRA.

  18. Electronic integrated disease surveillance system and pathogen asset control system.

    Science.gov (United States)

    Wahl, Tom G; Burdakov, Aleksey V; Oukharov, Andrey O; Zhilokov, Azamat K

    2012-06-20

    Electronic Integrated Disease Surveillance System (EIDSS) has been used to strengthen and support monitoring and prevention of dangerous diseases within One Health concept by integrating veterinary and human surveillance, passive and active approaches, case-based records including disease-specific clinical data based on standardised case definitions and aggregated data, laboratory data including sample tracking linked to each case and event with test results and epidemiological investigations. Information was collected and shared in secure way by different means: through the distributed nodes which are continuously synchronised amongst each other, through the web service, through the handheld devices. Electronic Integrated Disease Surveillance System provided near real time information flow that has been then disseminated to the appropriate organisations in a timely manner. It has been used for comprehensive analysis and visualisation capabilities including real time mapping of case events as these unfold enhancing decision making. Electronic Integrated Disease Surveillance System facilitated countries to comply with the IHR 2005 requirements through a data transfer module reporting diseases electronically to the World Health Organisation (WHO) data center as well as establish authorised data exchange with other electronic system using Open Architecture approach. Pathogen Asset Control System (PACS) has been used for accounting, management and control of biological agent stocks. Information on samples and strains of any kind throughout their entire lifecycle has been tracked in a comprehensive and flexible solution PACS.Both systems have been used in a combination and individually. Electronic Integrated Disease Surveillance System and PACS are currently deployed in the Republics of Kazakhstan, Georgia and Azerbaijan as a part of the Cooperative Biological Engagement Program (CBEP) sponsored by the US Defense Threat Reduction Agency (DTRA).

  19. Survey of Clostridium difficile infection surveillance systems in Europe, 2011.

    Science.gov (United States)

    Kola, Axel; Wiuff, Camilla; Akerlund, Thomas; van Benthem, Birgit H; Coignard, Bruno; Lyytikäinen, Outi; Weitzel-Kage, Doris; Suetens, Carl; Wilcox, Mark H; Kuijper, Ed J; Gastmeier, Petra

    2016-07-21

    To develop a European surveillance protocol for Clostridium difficile infection (CDI), existing national CDI surveillance systems were assessed in 2011. A web-based electronic form was provided for all national coordinators of the European CDI Surveillance Network (ECDIS-Net). Of 35 national coordinators approached, 33 from 31 European countries replied. Surveillance of CDI was in place in 14 of the 31 countries, comprising 18 different nationwide systems. Three of 14 countries with CDI surveillance used public health notification of cases as the route of reporting, and in another three, reporting was limited to public health notification of cases of severe CDI. The CDI definitions published by the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) and the European Centre for Disease Prevention and Control (ECDC) were widely used, but there were differing definitions to distinguish between community- and healthcare-associated cases. All CDI surveillance systems except one reported annual national CDI rates (calculated as number of cases per patient-days). Only four surveillance systems regularly integrated microbiological data (typing and susceptibility testing results). Surveillance methods varied considerably between countries, which emphasises the need for a harmonised European protocol to allow consistent monitoring of the CDI epidemiology at European level. The results of this survey were used to develop a harmonised EU-wide hospital-based CDI surveillance protocol. This article is copyright of The Authors, 2016.

  20. Risk analysis of a video-surveillance system

    NARCIS (Netherlands)

    Rothkrantz, L.; Lefter, I.

    2011-01-01

    The paper describes a surveillance system of cameras installed at lamppost of a military area. The surveillance system has been designed to detect unwanted visitors or suspicious behaviors. The area is composed of streets, building blocks and surrounded by gates and water. The video recordings are

  1. Surveillance System for Infectious Diseases of Pets, Santiago, Chile

    Science.gov (United States)

    López, Javier; Abarca, Katia; Valenzuela, Berta; Lorca, Lilia; Olea, Andrea; Aguilera, Ximena

    2009-01-01

    Pet diseases may pose risks to human health but are rarely included in surveillance systems. A pilot surveillance system of pet infectious diseases in Santiago, Chile, found that 4 canine and 3 feline diseases accounted for 90.1% and 98.4% of notifications, respectively. Data also suggested association between poverty and pet diseases. PMID:19861073

  2. Secure Video Surveillance System (SVSS) for unannounced safeguards inspections

    International Nuclear Information System (INIS)

    Galdoz, Erwin G.; Pinkalla, Mark

    2010-01-01

    The Secure Video Surveillance System (SVSS) is a collaborative effort between the U.S. Department of Energy (DOE), Sandia National Laboratories (SNL), and the Brazilian-Argentine Agency for Accounting and Control of Nuclear Materials (ABACC). The joint project addresses specific requirements of redundant surveillance systems installed in two South American nuclear facilities as a tool to support unannounced inspections conducted by ABACC and the International Atomic Energy Agency (IAEA). The surveillance covers the critical time (as much as a few hours) between the notification of an inspection and the access of inspectors to the location in facility where surveillance equipment is installed. ABACC and the IAEA currently use the EURATOM Multiple Optical Surveillance System (EMOSS). This outdated system is no longer available or supported by the manufacturer. The current EMOSS system has met the project objective; however, the lack of available replacement parts and system support has made this system unsustainable and has increased the risk of an inoperable system. A new system that utilizes current technology and is maintainable is required to replace the aging EMOSS system. ABACC intends to replace one of the existing ABACC EMOSS systems by the Secure Video Surveillance System. SVSS utilizes commercial off-the shelf (COTS) technologies for all individual components. Sandia National Laboratories supported the system design for SVSS to meet Safeguards requirements, i.e. tamper indication, data authentication, etc. The SVSS consists of two video surveillance cameras linked securely to a data collection unit. The collection unit is capable of retaining historical surveillance data for at least three hours with picture intervals as short as 1sec. Images in .jpg format are available to inspectors using various software review tools. SNL has delivered two SVSS systems for test and evaluation at the ABACC Safeguards Laboratory. An additional 'proto-type' system remains

  3. Cost analysis of various low pathogenic avian influenza surveillance systems in the Dutch egg layer sector.

    Directory of Open Access Journals (Sweden)

    Niels Rutten

    Full Text Available BACKGROUND: As low pathogenic avian influenza viruses can mutate into high pathogenic viruses the Dutch poultry sector implemented a surveillance system for low pathogenic avian influenza (LPAI based on blood samples. It has been suggested that egg yolk samples could be sampled instead of blood samples to survey egg layer farms. To support future decision making about AI surveillance economic criteria are important. Therefore a cost analysis is performed on systems that use either blood or eggs as sampled material. METHODOLOGY/PRINCIPAL FINDINGS: The effectiveness of surveillance using egg or blood samples was evaluated using scenario tree models. Then an economic model was developed that calculates the total costs for eight surveillance systems that have equal effectiveness. The model considers costs for sampling, sample preparation, sample transport, testing, communication of test results and for the confirmation test on false positive results. The surveillance systems varied in sampled material (eggs or blood, sampling location (farm or packing station and location of sample preparation (laboratory or packing station. It is shown that a hypothetical system in which eggs are sampled at the packing station and samples prepared in a laboratory had the lowest total costs (i.e. € 273,393 a year. Compared to this a hypothetical system in which eggs are sampled at the farm and samples prepared at a laboratory, and the currently implemented system in which blood is sampled at the farm and samples prepared at a laboratory have 6% and 39% higher costs respectively. CONCLUSIONS/SIGNIFICANCE: This study shows that surveillance for avian influenza on egg yolk samples can be done at lower costs than surveillance based on blood samples. The model can be used in future comparison of surveillance systems for different pathogens and hazards.

  4. Comparing national infectious disease surveillance systems: China and the Netherlands.

    NARCIS (Netherlands)

    Vlieg, Willemijn L; Fanoy, Ewout B; van Asten, Liselotte; Liu, Xiaobo; Yang, Jun; Pilot, Eva; Bijkerk, Paul; van der Hoek, Wim; Krafft, Thomas; van der Sande, Marianne A; Liu, Qi-Yong

    2017-01-01

    Risk assessment and early warning (RAEW) are essential components of any infectious disease surveillance system. In light of the International Health Regulations (IHR)(2005), this study compares the organisation of RAEW in China and the Netherlands. The respective approaches towards surveillance of

  5. Weather-enabled future onboard surveillance and navigation systems

    Science.gov (United States)

    Mutuel, L.; Baillon, B.; Barnetche, B.; Delpy, P.

    2009-09-01

    With the increasing traffic and the development of business trajectories, there is a widespread need to anticipate any adverse weather conditions that could impact the performance of the flight or to use of atmospheric parameters to optimize trajectories. Current sensors onboard air transport are challenged to provide the required service, while new products for business jets and general aviation open the door to innovative assimilation of weather information in onboard surveillance and navigation. The paper aims at surveying current technology available to air transport aircraft and pointing out their shortcomings in view of the modernization proposed in SESAR and NextGen implementation plans. Foreseen innovations are then illustrated via results of ongoing research like FLYSAFE or standardization efforts, in particular meteorological datalink services and impact on Human-Machine Interface. The paper covers the operational need to avoid adverse weather like thunderstorm, icing, turbulence, windshear and volcanic ash, but also the requirement to control in 4D the trajectory through the integration of wind and temperature grids in the flight management. The former will lead to enhanced surveillance systems onboard the aircraft with new displays and new alerting schemes, ranging from targeted information supporting better re-planning to auto-escape strategies. The latter will be standard in next generation flight management systems. Finally both will rely on ATM products that will also assimilate weather information so that situational awareness is shared and decision is collaborative.

  6. Surveillance Analysis Computer System (SACS) software requirements specification (SRS)

    International Nuclear Information System (INIS)

    Glasscock, J.A.; Flanagan, M.J.

    1995-09-01

    This document is the primary document establishing requirements for the Surveillance Analysis Computer System (SACS) Database, an Impact Level 3Q system. The purpose is to provide the customer and the performing organization with the requirements for the SACS Project

  7. Real Time Wide Area Radiation Surveillance System

    Science.gov (United States)

    Biafore, M.

    2012-04-01

    We present the REWARD project, financed within the FP7 programme, theme SEC-2011.1.5-1 (Development of detection capabilities of difficult to detect radioactive sources and nuclear materials - Capability Project). Within this project, we propose a novel mobile system for real time, wide area radiation surveillance. The system is based on the integration of new miniaturized solid-state radiation sensors: a CdZnTe detector for gamma radiation and a high efficiency neutron detector based on novel silicon technologies. The sensing unit will include a wireless communication interface to send the data remotely to a monitoring base station which also uses a GPS system to calculate the position of the tag. The system will also incorporate middleware and high level software to provide web-service interfaces for the exchange of information, and that will offer top level functionalities as management of users, mobile tags and environment data and alarms, database storage and management and a web-based graphical user interface. Effort will be spent to ensure that the software is modular and re-usable across as many architectural levels as possible. Finally, an expert system will continuously analyze the information from the radiation sensor and correlate it with historical data from the tag location in order to generate an alarm when an abnormal situation is detected. The system will be useful for many different scenarios, including such lost radioactive sources and radioactive contamination. It will be possible to deploy in emergency units and in general in any type of mobile or static equipment. The sensing units will be highly portable thanks to their low size and low energy consumption. The complete system will be scalable in terms of complexity and cost and will offer very high precision on both the measurement and the location of the radiation. The modularity and flexibility of the system will allow for a realistic introduction to the market. Authorities may start with a

  8. A Framework for People Re-Identification in Multi-Camera Surveillance Systems

    Science.gov (United States)

    Ammar, Sirine; Zaghden, Nizar; Neji, Mahmoud

    2017-01-01

    People re-identification has been a very active research topic recently in computer vision. It is an important application in surveillance system with disjoint cameras. This paper is focused on the implementation of a human re-identification system. First the face of detected people is divided into three parts and some soft-biometric traits are…

  9. FPGA-Based Real-Time Motion Detection for Automated Video Surveillance Systems

    Directory of Open Access Journals (Sweden)

    Sanjay Singh

    2016-03-01

    Full Text Available Design of automated video surveillance systems is one of the exigent missions in computer vision community because of their ability to automatically select frames of interest in incoming video streams based on motion detection. This research paper focuses on the real-time hardware implementation of a motion detection algorithm for such vision based automated surveillance systems. A dedicated VLSI architecture has been proposed and designed for clustering-based motion detection scheme. The working prototype of a complete standalone automated video surveillance system, including input camera interface, designed motion detection VLSI architecture, and output display interface, with real-time relevant motion detection capabilities, has been implemented on Xilinx ML510 (Virtex-5 FX130T FPGA platform. The prototyped system robustly detects the relevant motion in real-time in live PAL (720 × 576 resolution video streams directly coming from the camera.

  10. SCORPIO-VVER core monitoring and surveillance system with advanced capabilities

    International Nuclear Information System (INIS)

    Molnar, J.; Vocka, R.

    2010-01-01

    In this work authors present 12 years of operation experience of core monitoring and surveillance system with advanced capabilities on nuclear power plants on 6 unit of VVER-440 type of reactors at two different NPPs. The original version of the SCORPIO (Surveillance of reactor CORe by PIcture On-line display) system was developed for the western type of PWR reactors. The first version of the SCORPIO-VVER Core Monitoring System for Dukovany NPP (VVER-440 type of reactor, Czech Republic) was developed in 1998. For SCORPIO-VVER implementation at Bohunice NPP in Slovakia (2001) the system was enhanced with startup module KRITEX.

  11. An Autonomous Mobile Robotic System for Surveillance of Indoor Environments

    Directory of Open Access Journals (Sweden)

    Donato Di Paola

    2010-02-01

    Full Text Available The development of intelligent surveillance systems is an active research area. In this context, mobile and multi-functional robots are generally adopted as means to reduce the environment structuring and the number of devices needed to cover a given area. Nevertheless, the number of different sensors mounted on the robot, and the number of complex tasks related to exploration, monitoring, and surveillance make the design of the overall system extremely challenging. In this paper, we present our autonomous mobile robot for surveillance of indoor environments. We propose a system able to handle autonomously general-purpose tasks and complex surveillance issues simultaneously. It is shown that the proposed robotic surveillance scheme successfully addresses a number of basic problems related to environment mapping, localization and autonomous navigation, as well as surveillance tasks, like scene processing to detect abandoned or removed objects and people detection and following. The feasibility of the approach is demonstrated through experimental tests using a multisensor platform equipped with a monocular camera, a laser scanner, and an RFID device. Real world applications of the proposed system include surveillance of wide areas (e.g. airports and museums and buildings, and monitoring of safety equipment.

  12. An Autonomous Mobile Robotic System for Surveillance of Indoor Environments

    Directory of Open Access Journals (Sweden)

    Donato Di Paola

    2010-03-01

    Full Text Available The development of intelligent surveillance systems is an active research area. In this context, mobile and multi-functional robots are generally adopted as means to reduce the environment structuring and the number of devices needed to cover a given area. Nevertheless, the number of different sensors mounted on the robot, and the number of complex tasks related to exploration, monitoring, and surveillance make the design of the overall system extremely challenging. In this paper, we present our autonomous mobile robot for surveillance of indoor environments. We propose a system able to handle autonomously general-purpose tasks and complex surveillance issues simultaneously. It is shown that the proposed robotic surveillance scheme successfully addresses a number of basic problems related to environment mapping, localization and autonomous navigation, as well as surveillance tasks, like scene processing to detect abandoned or removed objects and people detection and following. The feasibility of the approach is demonstrated through experimental tests using a multisensor platform equipped with a monocular camera, a laser scanner, and an RFID device. Real world applications of the proposed system include surveillance of wide areas (e.g. airports and museums and buildings, and monitoring of safety equipment.

  13. Performance Assessment of a Communicable Disease Surveillance System in Response to the Twin Earthquakes of East Azerbaijan.

    Science.gov (United States)

    Babaie, Javad; Ardalan, Ali; Vatandoost, Hasan; Goya, Mohammad Mehdi; Akbari Sari, Ali

    2015-08-01

    Following the twin earthquakes on August 11, 2012, in the East Azerbaijan province of Iran, the provincial health center set up a surveillance system to monitor communicable diseases. This study aimed to assess the performance of this surveillance system. In this quantitative-qualitative study, performance of the communicable diseases surveillance system was assessed by using the updated guidelines of the Centers for Disease Control and Prevention (CDC). Qualitative data were collected through interviews with the surveillance system participants, and quantitative data were obtained from the surveillance system. The surveillance system was useful, simple, representative, timely, and flexible. The data quality, acceptability, and stability of the surveillance system were 65.6%, 10.63%, and 100%, respectively. The sensitivity and positive predictive value were not calculated owing to the absence of a gold standard. The surveillance system satisfactorily met the goals expected for its setup. The data obtained led to the control of communicable diseases in the affected areas. Required interventions based on the incidence of communicable disease were designed and implemented. The results also reassured health authorities and the public. However, data quality and acceptability should be taken into consideration and reviewed for implementation in future disasters.

  14. The Degree of One Health Implementation in the West Nile Virus Integrated Surveillance in Northern Italy, 2016

    Directory of Open Access Journals (Sweden)

    Giulia Paternoster

    2017-09-01

    Full Text Available West Nile virus (WNV is endemic in the Po valley area, Northern Italy, and within the legal framework of the national plan for the surveillance of human vector-borne diseases, WNV surveillance has over time been implemented. The surveillance plans are based on the transdisciplinary and trans-sectorial collaboration between regional institutions involved in public, animal, and environmental health. This integrated surveillance targets mosquitoes, wild birds, humans, and horses and aims at early detecting the viral circulation and reducing the risk of infection in the human populations. The objective of our study was to assess the degree of One Health (OH implementation (OH-ness of the WNV surveillance system in three North Italian regions (Emilia-Romagna, Lombardy, Piedmont in 2016, following the evaluation protocol developed by the Network for Evaluation of One Health (NEOH. In detail, we (i described the OH initiative (drivers, outcomes and its system (boundaries, aim, dimensions, actors, stakeholders and (ii scored different aspects of this initiative (i.e., OH-thinking, -planning, -sharing, -learning, transdisciplinarity and leadership, with values from 0 (=no OH approach to 1 (=perfect OH approach. We obtained a mean score for each aspect evaluated. We reached high scores for OH thinking (0.90 and OH planning (0.89. Lower scores were attributed to OH sharing (0.83, transdisciplinarity and leadership (0.77, and OH learning (0.67, highlighting some critical issues related to communication and learning gaps. The strengths and weaknesses detected by the described quantitative evaluation will be investigated in detail by a qualitative evaluation (process evaluation, aiming to provide a basis for the development of shared recommendations to refine the initiative and conduct it in a more OH-oriented perspective.

  15. Global Tobacco Surveillance System (GTSS) - Global Adult Tobacco Survey (GATS)

    Data.gov (United States)

    U.S. Department of Health & Human Services — 2008-2012. Centers for Disease Control and Prevention (CDC). Office on Smoking and Health (OSH) – Global Tobacco Surveillance System (GTSS) - Global Adult Tobacco...

  16. DASH - Youth Risk Behavior Surveillance System (YRBSS): High School

    Data.gov (United States)

    U.S. Department of Health & Human Services — 1991-2015. High School Dataset. The Youth Risk Behavior Surveillance System (YRBSS) monitors six categories of priority health behaviors among youth and young...

  17. Nutrition, Physical Activity, and Obesity - Behavioral Risk Factor Surveillance System

    Data.gov (United States)

    U.S. Department of Health & Human Services — This dataset includes data on adult's diet, physical activity, and weight status from Behavioral Risk Factor Surveillance System. This data is used for DNPAO's Data,...

  18. DASH - Youth Risk Behavior Surveillance System (YRBSS): Middle School

    Data.gov (United States)

    U.S. Department of Health & Human Services — 1991-2015. Middle School Dataset. The Youth Risk Behavior Surveillance System (YRBSS) monitors six categories of priority health behaviors among youth and young...

  19. Integrated design of intelligent surveillance systems and their user interface

    NARCIS (Netherlands)

    Toet, A.

    2005-01-01

    Modern complex surveillance systems consisting of multiple and heterogeneous sensors, automatic information registration and data analysis techniques, and decision support tools should provide the human operator an integrated, transparent and easily comprehensible view of the surveyed scene.

  20. CPSC’s National Electronic Injury Surveillance System (NEISS)

    Data.gov (United States)

    US Consumer Product Safety Commission — CPSC’s National Electronic Injury Surveillance System (NEISS) is a national probability sample of hospitals in the U.S. and its territories. Patient information is...

  1. Nutrition, Physical Activity, and Obesity - Youth Risk Behavior Surveillance System

    Data.gov (United States)

    U.S. Department of Health & Human Services — This dataset includes data on adolescent's diet, physical activity, and weight status from Youth Risk Behavior Surveillance System (YRBSS). This data is used for...

  2. Behavioral Risk Factor Surveillance System (BRFSS) Historical Questions

    Data.gov (United States)

    U.S. Department of Health & Human Services — 1984-2016. Centers for Disease Control and Prevention (CDC). BRFSS Survey Data. The BRFSS is a continuous, state-based surveillance system that collects information...

  3. ISS--an electronic syndromic surveillance system for infectious disease in rural China.

    Directory of Open Access Journals (Sweden)

    Weirong Yan

    Full Text Available BACKGROUND: Syndromic surveillance system has great advantages in promoting the early detection of epidemics and reducing the necessities of disease confirmation, and it is especially effective for surveillance in resource poor settings. However, most current syndromic surveillance systems are established in developed countries, and there are very few reports on the development of an electronic syndromic surveillance system in resource-constrained settings. OBJECTIVE: This study describes the design and pilot implementation of an electronic surveillance system (ISS for the early detection of infectious disease epidemics in rural China, complementing the conventional case report surveillance system. METHODS: ISS was developed based on an existing platform 'Crisis Information Sharing Platform' (CRISP, combining with modern communication and GIS technology. ISS has four interconnected functions: 1 work group and communication group; 2 data source and collection; 3 data visualization; and 4 outbreak detection and alerting. RESULTS: As of Jan. 31(st 2012, ISS has been installed and pilot tested for six months in four counties in rural China. 95 health facilities, 14 pharmacies and 24 primary schools participated in the pilot study, entering respectively 74,256, 79,701, and 2330 daily records into the central database. More than 90% of surveillance units at the study sites are able to send daily information into the system. In the paper, we also presented the pilot data from health facilities in the two counties, which showed the ISS system had the potential to identify the change of disease patterns at the community level. CONCLUSIONS: The ISS platform may facilitate the early detection of infectious disease epidemic as it provides near real-time syndromic data collection, interactive visualization, and automated aberration detection. However, several constraints and challenges were encountered during the pilot implementation of ISS in rural China.

  4. Information management in Iranian Maternal Mortality Surveillance System.

    Science.gov (United States)

    Sadoughi, Farahnaz; Karimi, Afsaneh; Erfannia, Leila

    2017-07-01

    Maternal mortality is preventable by proper information management and is the main target of the Maternal Mortality Surveillance System (MMSS). This study aimed to determine the status of information management in the Iranian Maternal Mortality Surveillance System (IMMSS). The population of this descriptive and analytical study, which was conducted in 2016, included 96 administrative staff of health and treatment deputies of universities of medical sciences and the Ministry of Health in Iran. Data were gathered by a five-part questionnaire with confirmed validity and reliability. A total of 76 questionnaires were completed, and data were analyzed using SPSS software, version 19, by descriptive and inferential statistics. The relationship between variables "organizational unit" and the four studied axes was studied using Kendall's correlation coefficient test. The status of information management in IMMSS was desirable. Data gathering and storage axis and data processing and compilation axis achieved the highest (2.7±0.46) and the lowest (2.4±0.49) mean scores, respectively. The data-gathering method, control of a sample of women deaths in reproductive age in the universities of medical sciences, use of international classification of disease, and use of this system information by management teams to set resources allocation achieved the lowest mean scores in studied axes. Treatment deputy staff had a more positive attitude toward the status of information management of IMMSS than the health deputy staff (p=0.004). Although the status of information management in IMMSS was desirable, it could be improved by modification of the data-gathering method; creating communication links between different data resources; a periodic sample control of women deaths in reproductive age in the universities of medical sciences; and implementing ICD-MM and integration of its rules on a unified system of death.

  5. The integrated proactive surveillance system for prostate cancer.

    Science.gov (United States)

    Wang, Haibin; Yatawara, Mahendra; Huang, Shao-Chi; Dudley, Kevin; Szekely, Christine; Holden, Stuart; Piantadosi, Steven

    2012-01-01

    In this paper, we present the design and implementation of the integrated proactive surveillance system for prostate cancer (PASS-PC). The integrated PASS-PC is a multi-institutional web-based system aimed at collecting a variety of data on prostate cancer patients in a standardized and efficient way. The integrated PASS-PC was commissioned by the Prostate Cancer Foundation (PCF) and built through the joint of efforts by a group of experts in medical oncology, genetics, pathology, nutrition, and cancer research informatics. Their main goal is facilitating the efficient and uniform collection of critical demographic, lifestyle, nutritional, dietary and clinical information to be used in developing new strategies in diagnosing, preventing and treating prostate cancer.The integrated PASS-PC is designed based on common industry standards - a three tiered architecture and a Service- Oriented Architecture (SOA). It utilizes open source software and programming languages such as HTML, PHP, CSS, JQuery, Drupal and MySQL. We also use a commercial database management system - Oracle 11g. The integrated PASS-PC project uses a "confederation model" that encourages participation of any interested center, irrespective of its size or location. The integrated PASS-PC utilizes a standardized approach to data collection and reporting, and uses extensive validation procedures to prevent entering erroneous data. The integrated PASS-PC controlled vocabulary is harmonized with the National Cancer Institute (NCI) Thesaurus. Currently, two cancer centers in the USA are participating in the integrated PASS-PC project.THE FINAL SYSTEM HAS THREE MAIN COMPONENTS: 1. National Prostate Surveillance Network (NPSN) website; 2. NPSN myConnect portal; 3. Proactive Surveillance System for Prostate Cancer (PASS-PC). PASS-PC is a cancer Biomedical Informatics Grid (caBIG) compatible product. The integrated PASS-PC provides a foundation for collaborative prostate cancer research. It has been built to

  6. Cost Analysis of Various Low Pathogenic Avian Influenza Surveillance Systems in the Dutch Egg Layer Sector

    NARCIS (Netherlands)

    Rutten, N.; Gonzales, J.L.; Elbers, A.R.; Velthuis, A.G.J.

    2012-01-01

    Background As low pathogenic avian influenza viruses can mutate into high pathogenic viruses the Dutch poultry sector implemented a surveillance system for low pathogenic avian influenza (LPAI) based on blood samples. It has been suggested that egg yolk samples could be sampled instead of blood

  7. Framework for evaluating public health surveillance systems for early detection of outbreaks: recommendations from the CDC Working Group.

    Science.gov (United States)

    Buehler, James W; Hopkins, Richard S; Overhage, J Marc; Sosin, Daniel M; Tong, Van

    2004-05-07

    The threat of terrorism and high-profile disease outbreaks has drawn attention to public health surveillance systems for early detection of outbreaks. State and local health departments are enhancing existing surveillance systems and developing new systems to better detect outbreaks through public health surveillance. However, information is limited about the usefulness of surveillance systems for outbreak detection or the best ways to support this function. This report supplements previous guidelines for evaluating public health surveillance systems. Use of this framework is intended to improve decision-making regarding the implementation of surveillance for outbreak detection. Use of a standardized evaluation methodology, including description of system design and operation, also will enhance the exchange of information regarding methods to improve early detection of outbreaks. The framework directs particular attention to the measurement of timeliness and validity for outbreak detection. The evaluation framework is designed to support assessment and description of all surveillance approaches to early detection, whether through traditional disease reporting, specialized analytic routines for aberration detection, or surveillance using early indicators of disease outbreaks, such as syndromic surveillance.

  8. Feasibility of using pedometers in a state-based surveillance system: 2014 Arizona Behavioral Risk Factor Surveillance System

    Directory of Open Access Journals (Sweden)

    Alberto Flórez-Pregonero

    2018-01-01

    Conclusion: The feasibility of using pedometers in a state-based surveillance system is modest at best. Feasibility may potentially be improved with easy-to-use pedometers where data can be electronically downloaded.

  9. Internet-based surveillance systems for monitoring emerging infectious diseases.

    Science.gov (United States)

    Milinovich, Gabriel J; Williams, Gail M; Clements, Archie C A; Hu, Wenbiao

    2014-02-01

    Emerging infectious diseases present a complex challenge to public health officials and governments; these challenges have been compounded by rapidly shifting patterns of human behaviour and globalisation. The increase in emerging infectious diseases has led to calls for new technologies and approaches for detection, tracking, reporting, and response. Internet-based surveillance systems offer a novel and developing means of monitoring conditions of public health concern, including emerging infectious diseases. We review studies that have exploited internet use and search trends to monitor two such diseases: influenza and dengue. Internet-based surveillance systems have good congruence with traditional surveillance approaches. Additionally, internet-based approaches are logistically and economically appealing. However, they do not have the capacity to replace traditional surveillance systems; they should not be viewed as an alternative, but rather an extension. Future research should focus on using data generated through internet-based surveillance and response systems to bolster the capacity of traditional surveillance systems for emerging infectious diseases. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. A New Molecular Surveillance System for Leishmaniasis

    Science.gov (United States)

    Pandey, Kishor; Pandey, Basu Dev; Mallik, Arun Kumar; Acharya, Jyoti; Kato, Kentaro; Kaneko, Osamu; Ferreira, Pedro Eduardo

    2014-01-01

    Abstract. Presently, global efforts are being made to control and eradicate the deadliest tropical diseases through the improvement of adequate interventions. A critical point for programs to succeed is the prompt and accurate diagnosis in endemic regions. Rapid diagnostic tests (RDTs) are being massively deployed and used to improve diagnosis in tropical countries. In the present report, we evaluated the hypothesis of, after use for diagnosis, the reuse of the Leishmania RDT kit as a DNA source, which can be used downstream as a molecular surveillance and/or quality control tool. As a proof of principle, a polymerase chain reaction-based method was used to detect Leishmania spp. minicircle kinetoplast DNA from leishmaniasis RDT kits. Our results show that Leishmania spp. DNA can be extracted from used RDTs and may constitute an important, reliable, and affordable tool to assist in future leishmaniasis molecular surveillance methods. PMID:24752687

  11. Developing a surveillance system for HIV/AIDS in Pakistan

    International Nuclear Information System (INIS)

    Emmanuel, F.; Bokhari, A.

    2006-01-01

    Apart from other interventions, surveillance remains a major focus of the national response to HIV/AIDS. However, with a shift in the epidemic pattern, the existing surveillance strategies are barely insufficient and long-term structural changes are desirable. This article provides a conceptual framework for developing a scientific system for HIV surveillance in Pakistan. Second generation surveillance system including repeated cross-sectional surveys in high risk population groups are suggested to collect behavioral and serological data at regular intervals on an annual basis to monitor the epidemic trend as well as the associated behaviors. In addition, multiple data resources have been highlighted, which could be coordinated to describe the epidemic pattern in the country. This information should form the basis for national prevention planning and ought to be used for making sensible choices through which prevention efforts are most likely to reduce new infections. (author)

  12. Suboptimal processor for anomaly detection for system surveillance and diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Ciftcioglu, Oe.; Hoogenboom, J.E.; Dam, H. van

    1989-06-01

    Anomaly detection for nuclear reactor surveillance and diagnosis is described. The residual noise obtained as a result of autoregressive (AR) modelling is essential to obtain high sensitivity for anomaly detection. By means of the method of hypothesis testing a suboptimal anomaly detection processor is devised for system surveillance and diagnosis. Experiments are carried out to investigate the performance of the processor, which is in particular of interest for on-line and real-time applications.

  13. Descriptive review of tuberculosis surveillance systems across the circumpolar regions

    Directory of Open Access Journals (Sweden)

    Annie-Claude Bourgeois

    2016-04-01

    Full Text Available Background: Tuberculosis is highly prevalent in many Arctic areas. Members of the International Circumpolar Surveillance Tuberculosis (ICS-TB Working Group collaborate to increase knowledge about tuberculosis in Arctic regions. Objective: To establish baseline knowledge of tuberculosis surveillance systems used by ICS-TB member jurisdictions. Design: Three questionnaires were developed to reflect the different surveillance levels (local, regional and national; all 3 were forwarded to the official representative of each of the 15 ICS-TB member jurisdictions in 2013. Respondents self-identified the level of surveillance conducted in their region and completed the applicable questionnaire. Information collected included surveillance system objectives, case definitions, data collection methodology, storage and dissemination. Results: Thirteen ICS-TB jurisdictions [Canada (Labrador, Northwest Territories, Nunavik, Nunavut, Yukon, Finland, Greenland, Norway, Sweden, Russian Federation (Arkhangelsk, Khanty-Mansiysk Autonomous Okrug, Yakutia (Sakha Republic, United States (Alaska] voluntarily completed the survey – representing 2 local, 7 regional and 4 national levels. Tuberculosis reporting is mandatory in all jurisdictions, and case definitions are comparable across regions. The common objectives across systems are to detect outbreaks, and inform the evaluation/planning of public health programmes and policies. All jurisdictions collect data on confirmed active tuberculosis cases and treatment outcomes; 11 collect contact tracing results. Faxing of standardized case reporting forms is the most common reporting method. Similar core data elements are collected; 8 regions report genotyping results. Data are stored using customized programmes (n=7 and commercial software (n=6. Nine jurisdictions provide monthly, bi-annual or annual reports to principally government and/or scientific/medical audiences. Conclusion: This review successfully establishes

  14. Collecting syndromic surveillance data by mobile phone in rural India: implementation and feasibility

    Directory of Open Access Journals (Sweden)

    Vishal Diwan

    2015-04-01

    Full Text Available Background: Infectious disease surveillance has long been a challenge for countries like India, where 75% of the health care services are private and consist of both formal and informal health care providers. Infectious disease surveillance data are regularly collected from governmental and qualified private facilities, but not from the informal sector. This study describes a mobile-based syndromic surveillance system and its application in a resource-limited setting, collecting data on patients’ symptoms from formal and informal health care providers. Design: The study includes three formal and six informal health care providers from two districts of Madhya Pradesh, India. Data collectors were posted in the clinics during the providers’ working hours and entered patient information and infectious disease symptoms on the mobile-based syndromic surveillance system. Results: Information on 20,424 patients was collected in the mobile-based surveillance system. The five most common (overlapping symptoms were fever (48%, cough (38%, body ache (38%, headache (37%, and runny nose (22%. During the same time period, the government's disease surveillance program reported around 22,000 fever cases in one district as a whole. Our data – from a very small fraction of all health care providers – thus highlight an enormous underreporting in the official surveillance data, which we estimate here to capture less than 1% of the fever cases. Additionally, we found that patients from more than 600 villages visited the nine providers included in our study. Conclusions: The study demonstrated that a mobile-based system can be used for disease surveillance from formal and informal providers in resource-limited settings. People who have not used smartphones or even computers previously can, in a short timeframe, be trained to fill out surveillance forms and submit them from the device. Technology, including network connections, works sufficiently for disease

  15. Formal and informal surveillance systems: how to build links

    Directory of Open Access Journals (Sweden)

    S. Desvaux

    2015-11-01

    Full Text Available Within the framework of highly pathogenic avian influenza (HPAI surveillance in Vietnam, interviews were carried out with poultry farmers and local animal health operators in two municipalities of the Red River delta with a view to documenting the circulation of health information concerning poultry (content of the information; method, scope and speed of circulation; actors involved; actions triggered as a result of the information received; economic and social incentives for disseminating or withholding information. The main results show that (i active informal surveillance networks exist, (ii the alert levels vary and the measures applied by the poultry farmers are myriad and often far-removed from the official recommendations, and (iii the municipal veterinarian is at the interface between the formal and the informal surveillance systems. The conclusions emphasize the need for the authorities to separate distinctly surveillance and control activities, and to regionalize control strategies, taking into account epidemiological specificities and social dynamics at local level.

  16. Tamper Detection for Active Surveillance Systems

    DEFF Research Database (Denmark)

    Theodore, Tsesmelis; Christensen, Lars; Fihl, Preben

    2013-01-01

    If surveillance data are corrupted they are of no use to neither manually post-investigation nor automatic video analysis. It is therefore critical to automatically be able to detect tampering events such as defocusing, occlusion and displacement. In this work we for the first time ad- dress...... of different tampering events. In order to assess the developed methods we have collected a large data set, which contains sequences from different active cameras at different scenarios. We evaluate our sys- tem on these data and the results are encouraging with a very high detecting rate and relatively few...

  17. Real-time implementations of acoustic signal enhancement techniques for aerial based surveillance and rescue applications

    Science.gov (United States)

    Ramos, Antonio L. L.; Shao, Zhili; Holthe, Aleksander; Sandli, Mathias F.

    2017-05-01

    The introduction of the System-on-Chip (SoC) technology has brought exciting new opportunities for the development of smart low cost embedded systems spanning a wide range of applications. Currently available SoC devices are capable of performing high speed digital signal processing tasks in software while featuring relatively low development costs and reduced time-to-market. Unmanned aerial vehicles (UAV) are an application example that has shown tremendous potential in an increasing number of scenarios, ranging from leisure to surveillance as well as in search and rescue missions. Video capturing from UAV platforms is a relatively straightforward task that requires almost no preprocessing. However, that does not apply to audio signals, especially in cases where the data is to be used to support real-time decision making. In fact, the enormous amount of acoustic interference from the surroundings, including the noise from the UAVs propellers, becomes a huge problem. This paper discusses a real-time implementation of the NLMS adaptive filtering algorithm applied to enhancing acoustic signals captured from UAV platforms. The model relies on a combination of acoustic sensors and a computational inexpensive algorithm running on a digital signal processor. Given its simplicity, this solution can be incorporated into the main processing system of an UAV using the SoC technology, and run concurrently with other required tasks, such as flight control and communications. Simulations and real-time DSP-based implementations have shown significant signal enhancement results by efficiently mitigating the interference from the noise generated by the UAVs propellers as well as from other external noise sources.

  18. Vector-borne disease surveillance in livestock populations: a critical review of literature recommendations and implemented surveillance (BTV-8) in five European countries

    DEFF Research Database (Denmark)

    Dórea, Fernanda C.; Elbers, Armin R.W.; Hendrikx, Pascal

    2016-01-01

    Preparedness against vector-borne threats depends on the existence of a long-term, sustainable surveillance of vector-borne disease and their relevant vectors. This work reviewed the availability of such surveillance systems in five European countries (Denmark, France, The Netherlands, Sweden and...

  19. Diseño y puesta en marcha de un sistema de vigilancia epidemiológica en salud mental Design and implementation of an epidemiological surveillance system for mental health

    Directory of Open Access Journals (Sweden)

    Judith Scharager Goldenberg

    2002-02-01

    a surveillance system to detect and rank the most significant mental health problems in a community and to establish their association with the living conditions in that community. Methods. The system was designed and tested at a primary health care center in the community of La Florida, which is in the metropolitan region of Santiago, the capital of Chile. The health problems that were under surveillance, with monthly monitoring, were: addiction (to alcohol, tobacco, and benzodiazepines or other drugs, violence (domestic violence and sexual abuse, real or suspected, and disorders in children (attention deficit and behavioral disorders. By means of a computerized geographical information system (GIS, those surveillance data were combined with other data. These other data included sociodemographic information on the persons who went to the health center for care as well as data on local risk factors and protective factors for health problems, some of which are indicators of the local residents' living conditions. Results. The proposed epidemiological surveillance system, which takes into account local living conditions and environmental variables, is a good tool for health action. The proposed system also complements the incomplete perspective of monitoring systems, which do not include variables describing the local context and that focus only on health problems. The information synthesized in the GIS maps makes it possible to simultaneously display different layers of information on factors related to the health problems studied, linked to a specific area and all its environmental variables, in an easy-to-read, self-explanatory format. Conclusions. These results and the concurring opinions of the participating physicians show that the experimental system effectively met the basic requirements of an epidemiological surveillance system of this kind.

  20. Establishment of a Canine Rabies Burden in Haiti through the Implementation of a Novel Surveillance Program

    Science.gov (United States)

    Wallace, Ryan M; Reses, Hannah; Franka, Richard; Dilius, Pierre; Fenelon, Natael; Orciari, Lillian; Etheart, Melissa; Destine, Apollon; Crowdis, Kelly; Blanton, Jesse D; Francisco, Calvin; Ludder, Fleurinord; Del Rio Vilas, Victor; Haim, Joseph; Millien, Max

    2015-01-01

    The Republic of Haiti is one of only several countries in the Western Hemisphere in which canine rabies is still endemic. Estimation methods have predicted that 130 human deaths occur per year, yet existing surveillance mechanisms have detected few of these rabies cases. Likewise, canine rabies surveillance capacity has had only limited capacity, detecting only two rabid dogs per year, on average. In 2013, Haiti initiated a community-based animal rabies surveillance program comprised of two components: active community bite investigation and passive animal rabies investigation. From January 2013 –December 2014, 778 rabies suspect animals were reported for investigation. Rabies was laboratory-confirmed in 70 animals (9%) and an additional 36 cases were identified based on clinical diagnosis (5%), representing an 18-fold increase in reporting of rabid animals compared to the three years before the program was implemented. Dogs were the most frequent rabid animal (90%). Testing and observation ruled out rabies in 61% of animals investigated. A total of 639 bite victims were reported to the program and an additional 364 bite victims who had not sought medical care were identified during the course of investigations. Only 31% of people with likely rabies exposures had initiated rabies post-exposure prophylaxis prior to the investigation. Rabies is a neglected disease in-part due to a lack of surveillance and understanding about the burden. The surveillance methods employed by this program established a much higher burden of canine rabies in Haiti than previously recognized. The active, community-based bite investigations identified numerous additional rabies exposures and bite victims were referred for appropriate medical care, averting potential human rabies deaths. The use of community-based rabies surveillance programs such as HARSP should be considered in canine rabies endemic countries. PMID:26600437

  1. Barriers to the Implementation of Surveillance for Stage I Testicular Seminoma

    International Nuclear Information System (INIS)

    Arvold, Nils D.; Catalano, Paul J.; Sweeney, Christopher J.; Hoffman, Karen E.; Nguyen, Paul L.; Balboni, Tracy A.; Fosså, Sophie D.; Travis, Lois B.; Beard, Clair J.

    2012-01-01

    Purpose: Postorchiectomy adjuvant radiotherapy (RT) for Stage I seminoma can be associated with long-term toxicity, and management strategies with a lower treatment burden achieve the same excellent cure rate. Because studies suggest that radiation oncologists in the United States continue to recommend RT for these patients, we sought to identify factors associated with management recommendations. Methods and Materials: We conducted a one-time internet-based survey among 491 randomly selected American radiation oncologists self-described as specializing in genitourinary oncology. Results: Response rate was 53% (n = 261). Forty-nine percent of respondents worked in university-affiliated practices. Sixty-two percent of respondents always/usually recommended adjuvant RT for patients with Stage I seminoma, whereas 21% always/usually recommended surveillance and 3% always/usually recommended chemotherapy. One third (33%) expressed concerns that patients who experienced relapse during surveillance could not be salvaged. Although 88% of physicians were aware of an increased risk of second malignant neoplasms (SMN) after adjuvant RT, 85% underestimated its magnitude. Compared with physicians not typically recommending RT, physicians who always/usually recommended RT were more likely to believe that patients might not be salvaged at relapse during surveillance (p = 0.008) and were less aware of the association between RT and SMN (p = 0.04). Conclusions: Respondents who always/usually recommend postorchiectomy RT for patients with Stage I seminoma are more likely to underestimate late RT morbidity and to believe that surveillance is associated with increased mortality. Given the equivalent efficacy and reduced morbidity of surveillance compared with RT, our findings underscore the need for ongoing physician education to increase appropriate clinical implementation of surveillance strategies.

  2. Barriers to the Implementation of Surveillance for Stage I Testicular Seminoma

    Energy Technology Data Exchange (ETDEWEB)

    Arvold, Nils D. [Harvard Radiation Oncology Program, Harvard Medical School, Boston, Massachusetts (United States); Catalano, Paul J. [Department of Biostatistics, Harvard School of Public Health, and Department of Biostatistics and Computational Biology, Dana-Farber Cancer Institute, Boston, Massachusetts (United States); Sweeney, Christopher J. [Department of Medical Oncology, Dana-Farber Cancer Institute, Boston, Massachusetts (United States); Hoffman, Karen E. [Department of Radiation Oncology, University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Nguyen, Paul L.; Balboni, Tracy A. [Department of Radiation Oncology, Brigham and Women' s Hospital and Dana-Farber Cancer Institute, Boston, Massachusetts (United States); Fossa, Sophie D. [Department of Clinical Research, Norwegian Radium Hospital, Oslo University, Oslo (Norway); Travis, Lois B. [Department of Radiation Oncology, University of Rochester Medical Center, Rochester, New York (United States); Beard, Clair J., E-mail: cbeard@lroc.harvard.edu [Department of Radiation Oncology, Brigham and Women' s Hospital and Dana-Farber Cancer Institute, Boston, Massachusetts (United States)

    2012-10-01

    Purpose: Postorchiectomy adjuvant radiotherapy (RT) for Stage I seminoma can be associated with long-term toxicity, and management strategies with a lower treatment burden achieve the same excellent cure rate. Because studies suggest that radiation oncologists in the United States continue to recommend RT for these patients, we sought to identify factors associated with management recommendations. Methods and Materials: We conducted a one-time internet-based survey among 491 randomly selected American radiation oncologists self-described as specializing in genitourinary oncology. Results: Response rate was 53% (n = 261). Forty-nine percent of respondents worked in university-affiliated practices. Sixty-two percent of respondents always/usually recommended adjuvant RT for patients with Stage I seminoma, whereas 21% always/usually recommended surveillance and 3% always/usually recommended chemotherapy. One third (33%) expressed concerns that patients who experienced relapse during surveillance could not be salvaged. Although 88% of physicians were aware of an increased risk of second malignant neoplasms (SMN) after adjuvant RT, 85% underestimated its magnitude. Compared with physicians not typically recommending RT, physicians who always/usually recommended RT were more likely to believe that patients might not be salvaged at relapse during surveillance (p = 0.008) and were less aware of the association between RT and SMN (p = 0.04). Conclusions: Respondents who always/usually recommend postorchiectomy RT for patients with Stage I seminoma are more likely to underestimate late RT morbidity and to believe that surveillance is associated with increased mortality. Given the equivalent efficacy and reduced morbidity of surveillance compared with RT, our findings underscore the need for ongoing physician education to increase appropriate clinical implementation of surveillance strategies.

  3. IMPLEMENTATION OF AERONAUTICAL LOCAL SATELLITE AUGMENTATION SYSTEM

    Directory of Open Access Journals (Sweden)

    Stojce Ilcev

    2011-03-01

    Full Text Available Abstract. This paper introduces development and implementation of new Local Satellite AugmentationSystem as an integration component of the Regional Satellite Augmentation System (RSAS employingcurrent and new Satellite Communications, Navigation and Surveillance (CNS for improvement of the AirTraffic Control (ATC and Air Traffic Management (ATM and for enhancement safety systems includingtransport security and control of flights in all stages, airport approaching, landing, departures and allmovements over airport surface areas. The current first generation of the Global Navigation Satellite SystemGNSS-1 applications are represented by fundamental military solutions for Position, Velocity and Time ofthe satellite navigation and determination systems such as the US GPS and Russian GLONASS (Former-USSR requirements, respectively. The establishment of Aeronautical CNS is also discussed as a part ofGlobal Satellite Augmentation Systems of GPS and GLONASS systems integrated with existing and futureRSAS and LSAS in airports areas. Specific influence and factors related to the Comparison of the Currentand New Aeronautical CNS System including the Integration of RSAS and GNSS solutions are discussedand packet of facts is determined to maximize the new satellite Automatic Dependent Surveillance System(ADSS and Special Effects of the RSAS Networks. The possible future integration of RSAS and GNSS andthe common proposal of the satellite Surface Movement Guidance and Control are presented in thechangeless ways as of importance for future enfacements of ATC and ATM for any hypothetical airportinfrastructure.Keywords: ADSS, ATC, ATM, CNS, GSAS, LRAS, RSAS, SMGC, Special Effects of RSAS.

  4. [Development of an index system for the comprehensive evaluation on public health emergency events surveillance system in China].

    Science.gov (United States)

    Hong, Zhiheng; Ni, Daxin; Cao, Yang; Meng, Ling; Tu, Wenxiao; Li, Leilei; Li, Qun; Jin, Lianmei

    2015-06-01

    To establish a comprehensive evaluation index system for the China Public Health Emergency Events Surveillance System (CPHEESS). A draft index system was built through literature review and under the consideration of the characteristics on CPHEESS. Delphi method was adapted to determine the final index system. The index system was divided into primary, secondary and tertiary levels. There were 4 primary indicators: System structure, Network platform, Surveillance implementation reports with Data analysis and utilization. There were 16 secondary and 70 tertiary indicators being set, with System structure including 14 tertiary indicators (accounted for 20.00%), 21 Network platforms (accounted for 30.00%). Twenty-four Surveillance implementation reports (accounted for 34.29%), 11 Data analysis and utilization (accounted for 15.71%). The average score of importance of each indicators was 4.29 (3.77-4.94), with an average coefficient variation as 0.14 (0.12-0.16). The mean Chronbach's α index was 0.84 (0.81-0.89). The adaptability of each related facilities indicator was specified. The primary indicators were set in accordance with the characteristics and goals of the surveillance systems. Secondary indicators provided key elements in the management and control of the system while the tertiary indicators were available and operative. The agreement rate of experts was high with good validity and reliability. This index system could be used for CPHEESS in future.

  5. Workers' health surveillance: implementation of the Directive 89/391/EEC in Europe.

    Science.gov (United States)

    Colosio, C; Mandic-Rajcevic, S; Godderis, L; van der Laan, G; Hulshof, C; van Dijk, F

    2017-10-01

    European Union (EU) Directive 89/391 addressed occupational health surveillance, which recommends to provide workers with 'access to health surveillance at regular intervals', aiming to prevent work-related and occupational diseases. To investigate how EU countries adopted this Directive. We invited one selected representative per member state to complete a questionnaire. All 28 EU countries implemented the Directive in some form. Workers' health surveillance (WHS) is available to all workers in 15 countries, while in 12, only specific subgroups have access. In 21 countries, workers' participation is mandatory, and in 22, the employer covers the cost. In 13 countries, access to WHS is not available to all workers but depends on exposure to specific risk factors, size of the enterprise or belonging to vulnerable groups. In 26 countries, the employer appoints and revokes the physician in charge of WHS. Twelve countries have no recent figures, reports or cost-benefit analyses of their WHS programmes. In 15 countries where reports exist, they are often in the native language. Coverage and quality of occupational health surveillance should be evaluated to facilitate learning from good practice and from scientific studies. We propose a serious debate in the EU with the aim of protecting workers more effectively, including the use of evidence-based WHS programmes. © The Author 2017. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  6. Hospital adoption of automated surveillance technology and the implementation of infection prevention and control programs.

    Science.gov (United States)

    Halpin, Helen; Shortell, Stephen M; Milstein, Arnold; Vanneman, Megan

    2011-05-01

    This research analyzes the relationship between hospital use of automated surveillance technology (AST) for identification and control of hospital-acquired infections (HAI) and implementation of evidence-based infection control practices. Our hypothesis is that hospitals that use AST have made more progress implementing infection control practices than hospitals that rely on manual surveillance. A survey of all acute general care hospitals in California was conducted from October 2008 through January 2009. A structured computer-assisted telephone interview was conducted with the quality director of each hospital. The final sample includes 241 general acute care hospitals (response rate, 83%). Approximately one third (32.4%) of California's hospitals use AST for monitoring HAI. Adoption of AST is statistically significant and positively associated with the depth of implementation of evidence-based practices for methicillin-resistant Staphylococcus aureus and ventilator-associated pneumonia and adoption of contact precautions and surgical care infection practices. Use of AST is also statistically significantly associated with the breadth of hospital implementation of evidence-based practices across all 5 targeted HAI. Our findings suggest that hospitals using AST can achieve greater depth and breadth in implementing evidenced-based infection control practices. Copyright © 2011 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  7. Evaluating the electronic tuberculosis register surveillance system in Eden District, Western Cape, South Africa, 2015.

    Science.gov (United States)

    Mlotshwa, Mandla; Smit, Sandra; Williams, Seymour; Reddy, Carl; Medina-Marino, Andrew

    2017-01-01

    Tuberculosis (TB) surveillance data are crucial to the effectiveness of National TB Control Programs. In South Africa, few surveillance system evaluations have been undertaken to provide a rigorous assessment of the platform from which the national and district health systems draws data to inform programs and policies. Evaluate the attributes of Eden District's TB surveillance system, Western Cape Province, South Africa. Data quality, sensitivity and positive predictive value were assessed using secondary data from 40,033 TB cases entered in Eden District's ETR.Net from 2007 to 2013, and 79 purposively selected TB Blue Cards (TBCs), a medical patient file and source document for data entered into ETR.Net. Simplicity, flexibility, acceptability, stability and usefulness of the ETR.Net were assessed qualitatively through interviews with TB nurses, information health officers, sub-district and district coordinators involved in the TB surveillance. TB surveillance system stakeholders report that Eden District's ETR.Net system was simple, acceptable, flexible and stable, and achieves its objective of informing TB control program, policies and activities. Data were less complete in the ETR.Net (66-100%) than in the TBCs (76-100%), and concordant for most variables except pre-treatment smear results, antiretroviral therapy (ART) and treatment outcome. The sensitivity of recorded variables in ETR.Net was 98% for gender, 97% for patient category, 93% for ART, 92% for treatment outcome and 90% for pre-treatment smear grading. Our results reveal that the system provides useful information to guide TB control program activities in Eden District. However, urgent attention is needed to address gaps in clinical recording on the TBC and data capturing into the ETR.Net system. We recommend continuous training and support of TB personnel involved with TB care, management and surveillance on TB data recording into the TBCs and ETR.Net as well as the implementation of a well

  8. Comparing national infectious disease surveillance systems: China and the Netherlands.

    Science.gov (United States)

    Vlieg, Willemijn L; Fanoy, Ewout B; van Asten, Liselotte; Liu, Xiaobo; Yang, Jun; Pilot, Eva; Bijkerk, Paul; van der Hoek, Wim; Krafft, Thomas; van der Sande, Marianne A; Liu, Qi-Yong

    2017-05-08

    Risk assessment and early warning (RAEW) are essential components of any infectious disease surveillance system. In light of the International Health Regulations (IHR)(2005), this study compares the organisation of RAEW in China and the Netherlands. The respective approaches towards surveillance of arboviral disease and unexplained pneumonia were analysed to gain a better understanding of the RAEW mode of operation. This study may be used to explore options for further strengthening of global collaboration and timely detection and surveillance of infectious disease outbreaks. A qualitative study design was used, combining data retrieved from the literature and from semi-structured interviews with Chinese (5 national-level and 6 provincial-level) and Dutch (5 national-level) experts. The results show that some differences exist such as in the use of automated electronic components of the early warning system in China ('CIDARS'), compared to a more limited automated component in the Netherlands ('barometer'). Moreover, RAEW units in the Netherlands focus exclusively on infectious diseases, while China has a broader 'all hazard' approach (including for example chemical incidents). In the Netherlands, veterinary specialists take part at the RAEW meetings, to enable a structured exchange/assessment of zoonotic signals. Despite these differences, the main conclusion is that for the two infections studied, the early warning system in China and the Netherlands are remarkably similar considering their large differences in infectious disease history, population size and geographical setting. Our main recommendations are continued emphasis on international corporation that requires insight into national infectious disease surveillance systems, the usage of a One Health approach in infectious disease surveillance, and further exploration/strengthening of a combined syndromic and laboratory surveillance system.

  9. A survey of core and support activities of communicable disease surveillance systems at operating-level CDCs in China.

    Science.gov (United States)

    Xiong, Weiyi; Lv, Jun; Li, Liming

    2010-11-17

    In recent years, problems like insufficient coordination, low efficiency, and heavy working load in national communicable disease surveillance systems in China have been pointed out by many researchers. To strengthen the national communicable disease surveillance systems becomes an immediate concern. Since the World Health Organization has recommended that a structured approach to strengthen national communicable disease surveillance must include an evaluation to existing systems which usually begins with a systematic description, we conducted the first survey for communicable disease surveillance systems in China, in order to understand the situation of core and support surveillance activities at province-level and county-level centers for disease control and prevention (CDCs). A nationwide survey was conducted by mail between May and October 2006 to investigate the implementation of core and support activities of the Notifiable Disease Reporting System (NDRS) and disease-specific surveillance systems in all of the 31 province-level and selected 14 county-level CDCs in Mainland China The comments on the performance of communicable disease surveillance systems were also collected from the directors of CDCs in this survey. The core activities of NDRS such as confirmation, reporting and analysis and some support activities such as supervision and staff training were found sufficient in both province-level and county-level surveyed CDCs, but other support activities including information feedback, equipment and financial support need to be strengthened in most of the investigated CDCs. A total of 47 communicable diseases or syndromes were under surveillance at province level, and 20 diseases or syndromes at county level. The activities among different disease-specific surveillance systems varied widely. Acute flaccid paralysis (AFP), measles and tuberculosis (TB) surveillance systems got relatively high recognition both at province level and county level. China has

  10. Health & demographic surveillance system profile: the Nahuche Health and Demographic Surveillance System, Northern Nigeria (Nahuche HDSS).

    Science.gov (United States)

    Alabi, Olatunji; Doctor, Henry V; Jumare, Abdulazeez; Sahabi, Nasiru; Abdulwahab, Ahmad; Findley, Sally E; Abubakar, Sani D

    2014-12-01

    The Nahuche Health and Demographic Surveillance System (HDSS) study site, established in 2009 with 137 823 individuals is located in Zamfara State, north western Nigeria. North-West Nigeria is a region with one of the worst maternal and child health indicators in Nigeria. For example, the 2013 Nigeria Demographic and Health Survey estimated an under-five mortality rate of 185 deaths per 1000 live births for the north-west geo-political zone compared with a national average of 128 deaths per 1000 live births. The site comprises over 100 villages under the leadership of six district heads. Virtually all the residents of the catchment population are Hausa by ethnicity. After a baseline census in 2010, regular update rounds of data collection are conducted every 6 months. Data collection on births, deaths, migration events, pregnancies, marriages and marriage termination events are routinely conducted. Verbal autopsy (VA) data are collected on all deaths reported during routine data collection. Annual update data on antenatal care and household characteristics are also collected. Opportunities for collaborations are available at Nahuche HDSS. The Director of Nahuche HDSS, M.O. Oche at [ochedr@hotmail.com] is the contact person for all forms of collaboration. © The Author 2014; all rights reserved. Published by Oxford University Press on behalf of the International Epidemiological Association.

  11. Health & Demographic Surveillance System profile: the Muzaffarpur-TMRC Health and Demographic Surveillance System.

    Science.gov (United States)

    Malaviya, Paritosh; Picado, Albert; Hasker, Epco; Ostyn, Bart; Kansal, Sangeeta; Singh, Rudra Pratap; Shankar, Ravi; Boelaert, Marleen; Sundar, Shyam

    2014-10-01

    The Muzaffarpur-TMRC Health and Demographic Surveillance System (HDSS), established in 2007, was developed as an enlargement of the scope of a research collaboration on the project Visceral Leishmaniasis in Bihar, which had been ongoing since 2005. The HDSS is located in a visceral leishmaniasis (VL)-endemic area in the Muzaffarpur district of Bihar state in India. It is the only HDSS conducting research on VL, which is a vector-borne infectious disease transmitted by female phlebotomine sandflies and is fatal if left untreated. Currently the HDSS serves a population of over 105,000 in 66 villages. The HDSS collects data on vital events including pregnancies, births, deaths, migration and marriages, as well as other socio-economic indicators, at regular intervals. Incident VL cases are identified. The HDSS team is experienced in conducting both qualitative and quantitative studies, sample collection and rapid diagnostic tests in the field. In each village, volunteers connect the HDSS team with the community members. The Muzaffarpur-TMRC HDSS provides opportunities for studies on VL and other neglected tropical diseases (NTDs) and their interaction with demographic events such as migration. Queries related to research collaborations and data sharing can be sent to Dr Shyam Sundar at [drshyamsundar@hotmail.com]. © The Author 2014; all rights reserved. Published by Oxford University Press on behalf of the International Epidemiological Association.

  12. Involving private healthcare practitioners in an urban NCD sentinel surveillance system: lessons learned from Pune, India.

    Science.gov (United States)

    Kroll, Mareike; Phalkey, Revati; Dutta, Sayani; Shukla, Sharvari; Butsch, Carsten; Bharucha, Erach; Kraas, Frauke

    2016-01-01

    Despite the rising impact of non-communicable diseases (NCDs) on public health in India, lack of quality data and routine surveillance hampers the planning process for NCD prevention and control. Current surveillance programs focus largely on communicable diseases and do not adequately include the private healthcare sector as a major source of care in cities. The objective of the study was to conceptualize, implement, and evaluate a prototype for an urban NCD sentinel surveillance system among private healthcare practitioners providing primary care in Pune, India. We mapped all private healthcare providers in three selected areas of the city, conducted a knowledge, attitude, and practice survey with regard to surveillance among 258 consenting practitioners, and assessed their willingness to participate in a routine NCD surveillance system. In total, 127 practitioners agreed and were included in a 6-month surveillance study. Data on first-time diagnoses of 10 selected NCDs alongside basic demographic and socioeconomic patient information were collected onsite on a monthly basis using a paper-based register. Descriptive and regression analyses were performed. In total, 1,532 incident cases were recorded that mainly included hypertension ( n =622, 41%) and diabetes ( n =460, 30%). Dropout rate was 10% ( n =13). The monthly reporting consistency was quite constant, with the majority ( n =63, 50%) submitting 1-10 cases in 6 months. Average number of submitted cases was highest among allopathic practitioners (17.4). A majority of the participants ( n =104, 91%) agreed that the surveillance design could be scaled up to cover the entire city. The study indicates that private primary healthcare providers (allopathic and alternate medicine practitioners) play an important role in the diagnosis and treatment of NCDs and can be involved in NCD surveillance, if certain barriers are addressed. Main barriers observed were lack of regulation of the private sector, cross

  13. Introduction to surveillance studies

    CERN Document Server

    Petersen, JK

    2012-01-01

    Introduction & OverviewIntroduction Brief History of Surveillance Technologies & TechniquesOptical SurveillanceAerial Surveillance Audio Surveillance Radio-Wave SurveillanceGlobal Positioning Systems Sensors Computers & the Internet Data Cards Biochemical Surveillance Animal Surveillance Biometrics Genetics Practical ConsiderationsPrevalence of Surveillance Effectiveness of Surveillance Freedom & Privacy IssuesConstitutional Freedoms Privacy Safeguards & Intrusions ResourcesReferences Glossary Index

  14. Surveillance of hazardous substances releases due to system interruptions, 2002.

    Science.gov (United States)

    Orr, Maureen F; Ruckart, Perri Zeitz

    2007-04-11

    The Hazardous Substances Emergency Events Surveillance (HSEES) system collected information on 9014 acute hazardous substance releases in 15 participating states in 2002. There were 3749 fixed-facility manufacturing events, of which 2100 involved "interruptions" to normal processing and 1649 "comparisons" that did not involve interruption. Equipment failure (69%) or intentional acts (20%) were the main root factor. Many events occurred in October and November in three states (Texas, Louisiana, and New Jersey), in three manufacturing industries (industrial and miscellaneous chemicals; petroleum refining; and plastics, synthetics, and resins). In interruption events, the substance categories most often released were mixtures, other inorganic substances, and volatile organic compounds and those most often causing injury were acids, chlorine, bases, and ammonia. Comparison events resulted in more acutely injured persons (408 versus 59) and more evacuees (11,318 versus 335) than interruption events and therefore may receive more public health attention. Because of the large number of interruption events, targeted prevention activities, including management of change procedures, lessons-learned implementation, process hazards analysis, and appropriate protection for workers could be economically advantageous and improve environmental quality. Efforts should focus on the identified areas of greater occurrence. The relationship of weather and equipment failure with interruption events needs further investigation.

  15. Will smart surveillance systems listen, understand and speak Slovene?

    Directory of Open Access Journals (Sweden)

    Simon Dobrišek

    2013-12-01

    Full Text Available The paper deals with the spoken language technologies that could enable the so-called smart (intelligent surveillance systems to listen, understand and speak Slovenian in the near future. Advanced computational methods of artificial perception and pattern recognition enable such systems to be at least to some extent aware of the environment, the presence of people and other phenomena that could be subject to surveillance. Speech is one such phenomenon that has the potential to be a key source of information in certain security situations. Technologies that enable automatic speech and speaker recognition as well as their psychophysical state by computer analysis of acoustic speech signals provide an entirely new dimension to the development of smart surveillance systems. Automatic recognition of spoken threats, screaming and crying for help, as well as a suspicious psycho-physical state of a speaker provide such systems to some extent with intelligent behaviour. The paper investigates the current state of development of these technologies and the requirements and possibilities of these systems to be used for the Slovenian spoken language, as well as different possible security application scenarios. It also addresses the broader legal and ethical issues raised by the development and use of such technologies, especially as audio surveillance is one of the most sensitive issues of privacy protection.

  16. A Radiation-Triggered Surveillance System for UF6 Cylinder Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Curtis, Michael M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Myjak, Mitchell J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-09-23

    This report provides background information and representative scenarios for testing a prototype radiation-triggered surveillance system at an operating facility that handles uranium hexafluoride (UF6) cylinders. The safeguards objective is to trigger cameras using radiation, or radiation and motion, rather than motion alone, to reduce significantly the number of image files generated by a motion-triggered system. The authors recommend the use of radiation-triggered surveillance at all facilities where cylinder paths are heavily traversed by personnel. The International Atomic Energy Agency (IAEA) has begun using surveillance cameras in the feed and withdrawal areas of gas centrifuge enrichment plants (GCEPs). The cameras generate imagery using elapsed time or motion, but this creates problems in areas occupied 24/7 by personnel. Either motion-or-interval-based triggering generates thousands of review files over the course of a month. Since inspectors must review the files to verify operator material-flow-declarations, a plethora of files significantly extends the review process. The primary advantage of radiation-triggered surveillance is the opportunity to obtain full-time cylinder throughput verification versus what presently amounts to part-time verification. Cost savings should be substantial, as the IAEA presently uses frequent unannounced inspections to verify cylinder-throughput declarations. The use of radiation-triggered surveillance allows the IAEA to implement less frequent unannounced inspections for the purpose of flow verification, but its principal advantage is significantly shorter and more effective inspector video reviews.

  17. Strengthening health security at the Hajj mass gatherings: characteristics of the infectious diseases surveillance systems operational during the 2015 Hajj.

    Science.gov (United States)

    Alotaibi, Badriah M; Yezli, Saber; Bin Saeed, Abdul-Aziz A; Turkestani, Abdulhafeez; Alawam, Amnah H; Bieh, Kingsley L

    2017-05-01

    Hajj is one of the largest and the most ethnically and culturally diverse mass gatherings worldwide. The use of appropriate surveillance systems ensures timely information management for effective planning and response to infectious diseases threats during the pilgrimage. The literature describes infectious diseases prevention and control strategies for Hajj but with limited information on the operations and characteristics of the existing Hajj infectious diseases surveillance systems. We reviewed documents, including guidelines and reports from the Saudi Ministry of Health's database, to describe the characteristics of the infectious diseases surveillance systems that were operational during the 2015 Hajj, highlighting best practices and gaps and proposing strategies for strengthening and improvement. Using Pubmed and Embase online search engines and a combination of search terms including, 'mass gatherings' 'Olympics' 'surveillance' 'Hajj' 'health security', we explored the existing literature and highlighted some lessons learnt from other international mass gatherings. A regular indicator-based infectious disease surveillance system generates routine reports from health facilities within the Kingdom to the regional and central public health directorates all year round. During Hajj, enhanced indicator-based notifiable diseases surveillance systems complement the existing surveillance tool to ensure timely reporting of event information for appropriate action by public health officials. There is need to integrate the existing Hajj surveillance data management systems and to implement syndromic surveillance as an early warning system for infectious disease control during Hajj. International engagement is important to strengthen Hajj infectious diseases surveillance and to prevent disease transmission and globalization of infectious agents which could undermine global health security. © International Society of Travel Medicine, 2017. Published by Oxford University

  18. Developing Agent-Oriented Video Surveillance System through Agent-Oriented Methodology (AOM

    Directory of Open Access Journals (Sweden)

    Cheah Wai Shiang

    2016-12-01

    Full Text Available Agent-oriented methodology (AOM is a comprehensive and unified agent methodology for agent-oriented software development. Although AOM is claimed to be able to cope with a complex system development, it is still not yet determined up to what extent this may be true. Therefore, it is vital to conduct an investigation to validate this methodology. This paper presents the adoption of AOM in developing an agent-oriented video surveillance system (VSS. An intruder handling scenario is designed and implemented through AOM. AOM provides an alternative method to engineer a distributed security system in a systematic manner. It presents the security system at a holistic view; provides a better conceptualization of agent-oriented security system and supports rapid prototyping as well as simulation of video surveillance system.

  19. A generic flexible and robust approach for intelligent real-time video-surveillance systems

    Science.gov (United States)

    Desurmont, Xavier; Delaigle, Jean-Francois; Bastide, Arnaud; Macq, Benoit

    2004-05-01

    In this article we present a generic, flexible and robust approach for an intelligent real-time video-surveillance system. A previous version of the system was presented in [1]. The goal of these advanced tools is to provide help to operators by detecting events of interest in visual scenes and highlighting alarms and compute statistics. The proposed system is a multi-camera platform able to handle different standards of video inputs (composite, IP, IEEE1394 ) and which can basically compress (MPEG4), store and display them. This platform also integrates advanced video analysis tools, such as motion detection, segmentation, tracking and interpretation. The design of the architecture is optimised to playback, display, and process video flows in an efficient way for video-surveillance application. The implementation is distributed on a scalable computer cluster based on Linux and IP network. It relies on POSIX threads for multitasking scheduling. Data flows are transmitted between the different modules using multicast technology and under control of a TCP-based command network (e.g. for bandwidth occupation control). We report here some results and we show the potential use of such a flexible system in third generation video surveillance system. We illustrate the interest of the system in a real case study, which is the indoor surveillance.

  20. Comparing national infectious disease surveillance systems : China and the Netherlands

    NARCIS (Netherlands)

    Vlieg, Willemijn L; Fanoy, Ewout B; van Asten, Liselotte; Liu, Xiaobo; Yang, Jun; Pilot, Eva; Bijkerk, Paul; van der Hoek, Wim; Krafft, Thomas; van der Sande, Marianne A; Liu, Qi-Yong

    2017-01-01

    BACKGROUND: Risk assessment and early warning (RAEW) are essential components of any infectious disease surveillance system. In light of the International Health Regulations (IHR)(2005), this study compares the organisation of RAEW in China and the Netherlands. The respective approaches towards

  1. Results of EMC market surveillance tests for UPS systems

    Energy Technology Data Exchange (ETDEWEB)

    Rajamaeki, J. [Safety Technology Authority, Helsinki (Finland)

    1997-12-31

    This paper reports the first wide electromagnetic compatibility (EMC) market surveillance project in Finland in which the uninterruptible power systems (UPS) on the Finnish market are monitored. Altogether 11 UPS units are EMC tested and the results of these tests are described in this paper. The effect of basic characters of UPS on the level of electromagnetic interference are analysed. (orig.) 3 refs.

  2. Considerations on a VXI based digital image surveillance system

    International Nuclear Information System (INIS)

    Gaertner, K.J.; Neumann, G.; Richter, B.

    1995-01-01

    In 1992 the International Atomic Energy Agency established the IAEA Integrated Safeguards Instrumentation Programme (I 2 SIP) which provides a conceptual framework to guide new equipment development activities. One of the main goals of I 2 SIP is to define the optimum structure of future safeguards equipment inventory that would enable the integration of containment, surveillance and unattended radiation monitoring modules for application in facilities with complex safeguards systems. This approach implies a modular equipment structure in both hardware and software. In December 1993, a Consultants Meeting concluded that the VXI instrument bus (VXIbus) standard does not appear to have any technical limitations that will inhibit the use of I 2 SIP and should be considered the first choice for future safeguards equipment. The Agency's development plan for Digital Image Surveillance (DIS) is part of the I 2 SIP and has defined the need for 'distributed systems', i.e. for multichannel surveillance systems, which should accommodate the integration aspect and meet requirements for both mail-in of recorded information to the Agency and remote surveillance. The paper describes the basic considerations that have led to the selection of the VXI bus to be used for such a system including the different modules emphasizing the integration issue

  3. INVIS : Integrated night vision surveillance and observation system

    NARCIS (Netherlands)

    Toet, A.; Hogervorst, M.A.; Dijk, J.; Son, R. van

    2010-01-01

    We present the design and first field trial results of the all-day all-weather INVIS Integrated Night Vision surveillance and observation System. The INVIS augments a dynamic three-band false-color nightvision image with synthetic 3D imagery in a real-time display. The night vision sensor suite

  4. Surveillance systems (PWR) - loose parts monitoring - vibration monitoring - leakage detection

    International Nuclear Information System (INIS)

    Schuette, A.; Blaesig, H.

    1982-01-01

    The contribution is engaged in the task and the results of the loose parts monitoring and the vibration monitoring following from the practice at the PWR of Biblis. First a description of both systems - location and type of the sensors used, the treatment of the measurements and the indications - is given. The results of the analysis of some events picked up by the surveillance systems are presented showing applicabilty and benefit of such systems. (orig.)

  5. Active surveillance for influenza vaccine adverse events: the integrated vaccine surveillance system.

    Science.gov (United States)

    Newes-Adeyi, Gabriella; Greece, Jacey; Bozeman, Sam; Walker, Deborah Klein; Lewis, Faith; Gidudu, Jane

    2012-02-01

    We conducted a pilot study of the Integrated Vaccine Surveillance System (IVSS), a novel active surveillance system for monitoring influenza vaccine adverse events that could be used in mass vaccination settings. We recruited 605 adult vaccinees from a convenience sample of 12 influenza vaccine clinics conducted by public health departments of two U.S. metropolitan regions. Vaccinees provided daily reports on adverse reactions following immunization (AEFI) using an interactive voice response system (IVR) or the internet for 14 consecutive days following immunization. Followup with nonrespondents was conducted through computer-assisted telephone interviewing (CATI). Data on vaccinee reports were available real-time through a dedicated secure website. 90% (545) of vaccinees made at least one daily report and 49% (299) reported consecutively for the full 14-day period. 58% (315) used internet, 20% (110) IVR, 6% (31) CATI, and 16% (89) used a combination for daily reports. Of the 545 reporters, 339 (62%) reported one or more AEFI, for a total of 594 AEFIs reported. The majority (505 or 85%) of these AEFIs were mild symptoms. It is feasible to develop a system to obtain real-time data on vaccine adverse events. Vaccinees are willing to provide daily reports for a considerable time post vaccination. Offering multiple modes of reporting encourages high response rates. Study findings on AEFIs showed that the IVSS was able to exhibit the emerging safety profile of the 2008 seasonal influenza vaccine. Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Surveillance indicators and their use in implementation of the Marine Strategy Framework Directive

    DEFF Research Database (Denmark)

    Shephard, Samuel; Greenstreet, Simon P. R.; Piet, GerJan J.

    2015-01-01

    The European Union Marine Strategy Framework Directive (MSFD) uses indicators to track ecosystem state in relation to Good Environmental Status (GES). These indicators were initially expected to be “operational”, i.e. to have well-understood relationships between state and specified anthropogenic...... pressure(s), and to have defined targets. Recent discussion on MSFD implementation has highlighted an additional class of “surveillance” indicators. Surveillance indicators monitor key aspects of the ecosystem for which there is: first, insufficient evidence to define targets and support formal state...

  7. A review of occupational disease surveillance systems in Modernet countries.

    Science.gov (United States)

    Carder, M; Bensefa-Colas, L; Mattioli, S; Noone, P; Stikova, E; Valenty, M; Telle-Lamberton, M

    2015-11-01

    To improve occupational health public policies and to facilitate coordinated research within the European Union to reduce the incidence of occupational diseases (ODs), it is important to know what OD surveillance systems exist and how they compare. Monitoring trends in occupational diseases and tracing new and emerging risks in a network (Modernet) participants are well placed to provide this information as most either contribute data to and/or are involved in the management of OD systems. To identify and describe OD surveillance systems in Modernet countries with the longer-term objective of identifying a core template to be used on a large scale. A questionnaire sent to Modernet participants, seeking structured information about the OD surveillance system(s) in their country. Overall 14 countries (70%) provided information for 33 OD systems, among them 11 compensation-based (CB) systems. Six countries provided information for non-CB systems reporting for any type of OD. The other systems reported either only ODs from a prescribed list, or specific diagnoses or diagnostic groups, with reports to most schemes being physician-based. Data collected varied but all systems collected diagnosis, age, gender, date reported and occupation (and/or industry) and most collected information on exposure. This review provides information beneficial to both policy makers and researchers by identifying data sources useable to measure OD trends in European countries and opening the way to future work, both on trend comparisons within Europe and on the definition of a core template to extend OD surveillance on a larger scale. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Designing and evaluating risk-based surveillance systems

    DEFF Research Database (Denmark)

    Willeberg, Preben; Nielsen, Liza Rosenbaum; Salman, Mo

    2012-01-01

    Risk-based surveillance systems reveal occurrence of disease or infection in a sample of population units, which are selected on the basis of risk factors for the condition under study. The purpose of such systems for supporting practical animal disease policy formulations and management decisions...... with prudent use of resources while maintaining acceptable system performance. High-risk category units are selected for testing by identification of the presence of specific high-risk factor(s), while disregarding other factors that might also influence the risk. On this basis we argue that the most...... applicable risk estimate for use in designing and evaluating a risk-based surveillance system would be a crude (unadjusted) relative risk, odds ratio or apparent prevalence. Risk estimates found in the published literature, however, are often the results of multivariable analyses implicitly adjusting...

  9. Evaluation of the influenza sentinel surveillance system in Madagascar, 2009-2014.

    Science.gov (United States)

    Rakotoarisoa, Alain; Randrianasolo, Laurence; Tempia, Stefano; Guillebaud, Julia; Razanajatovo, Norosoa; Randriamampionona, Lea; Piola, Patrice; Halm, Ariane; Heraud, Jean-Michel

    2017-05-01

    Evaluation of influenza surveillance systems is poor, especially in Africa. In 2007, the Institut Pasteur de Madagascar and the Malagasy Ministry of Public Health implemented a countrywide system for the prospective syndromic and virological surveillance of influenza-like illnesses. In assessing this system's performance, we identified gaps and ways to promote the best use of resources. We investigated acceptability, data quality, flexibility, representativeness, simplicity, stability, timeliness and usefulness and developed qualitative and/or quantitative indicators for each of these attributes. Until 2007, the influenza surveillance system in Madagascar was only operational in Antananarivo and the observations made could not be extrapolated to the entire country. By 2014, the system covered 34 sentinel sites across the country. At 12 sites, nasopharyngeal and/or oropharyngeal samples were collected and tested for influenza virus. Between 2009 and 2014, 177 718 fever cases were detected, 25 809 (14.5%) of these fever cases were classified as cases of influenza-like illness. Of the 9192 samples from patients with influenza-like illness that were tested for influenza viruses, 3573 (38.9%) tested positive. Data quality for all evaluated indicators was categorized as above 90% and the system also appeared to be strong in terms of its acceptability, simplicity and stability. However, sample collection needed improvement. The influenza surveillance system in Madagascar performed well and provided reliable and timely data for public health interventions. Given its flexibility and overall moderate cost, this system may become a useful platform for syndromic and laboratory-based surveillance in other low-resource settings.

  10. Wireless sensor network for mobile surveillance systems; 2005BU1-TRSP

    NARCIS (Netherlands)

    Maris, M.G.; Dijk, G.J.A. van

    2005-01-01

    Guarding safety and security within industrial, commercial and military areas is an important issue nowadays. A specific challenge lies in the design of portable surveillance systems that can be rapidly deployed, installed and easily operated. Conventional surveillance systems typically employ

  11. Parallel Computational Intelligence-Based Multi-Camera Surveillance System

    OpenAIRE

    Orts-Escolano, Sergio; Garcia-Rodriguez, Jose; Morell, Vicente; Cazorla, Miguel; Azorin-Lopez, Jorge; García-Chamizo, Juan Manuel

    2014-01-01

    In this work, we present a multi-camera surveillance system based on the use of self-organizing neural networks to represent events on video. The system processes several tasks in parallel using GPUs (graphic processor units). It addresses multiple vision tasks at various levels, such as segmentation, representation or characterization, analysis and monitoring of the movement. These features allow the construction of a robust representation of the environment and interpret the behavior of mob...

  12. Computational methods and implementation of the 3-D PWR core dynamics SIMTRAN code for online surveillance and prediction

    International Nuclear Information System (INIS)

    Aragones, J.M.; Ahnert, C.

    1995-01-01

    New computational methods have been developed in our 3-D PWR core dynamics SIMTRAN code for online surveillance and prediction. They improve the accuracy and efficiency of the coupled neutronic-thermalhydraulic solution and extend its scope to provide, mainly, the calculation of: the fission reaction rates at the incore mini-detectors; the responses at the excore detectors (power range); the temperatures at the thermocouple locations; and the in-vessel distribution of the loop cold-leg inlet coolant conditions in the reflector and core channels, and to the hot-leg outlets per loop. The functional capabilities implemented in the extended SIMTRAN code for online utilization include: online surveillance, incore-excore calibration, evaluation of peak power factors and thermal margins, nominal update and cycle follow, prediction of maneuvers and diagnosis of fast transients and oscillations. The new code has been installed at the Vandellos-II PWR unit in Spain, since the startup of its cycle 7 in mid-June, 1994. The computational implementation has been performed on HP-700 workstations under the HP-UX Unix system, including the machine-man interfaces for online acquisition of measured data and interactive graphical utilization, in C and X11. The agreement of the simulated results with the measured data, during the startup tests and first months of actual operation, is well within the accuracy requirements. The performance and usefulness shown during the testing and demo phase, to be extended along this cycle, has proved that SIMTRAN and the man-machine graphic user interface have the qualities for a fast, accurate, user friendly, reliable, detailed and comprehensive online core surveillance and prediction

  13. Vector Borne Infections in Italy: Results of the Integrated Surveillance System for West Nile Disease in 2013

    Directory of Open Access Journals (Sweden)

    Christian Napoli

    2015-01-01

    Full Text Available The epidemiology of West Nile disease (WND is influenced by multiple ecological factors and, therefore, integrated surveillance systems are needed for early detecting the infection and activating consequent control actions. As different animal species have different importance in the maintenance and in the spread of the infection, a multispecies surveillance approach is required. An integrated and comprehensive surveillance system is in place in Italy aiming at early detecting the virus introduction, monitoring the possible infection spread, and implementing preventive measures for human health. This paper describes the integrated surveillance system for WND in Italy, which incorporates data from veterinary and human side in order to evaluate the burden of infection in animals and humans and provide the public health authorities at regional and national levels with the information needed for a fine tune response.

  14. A GIS-driven integrated real-time surveillance pilot system for national West Nile virus dead bird surveillance in Canada

    Directory of Open Access Journals (Sweden)

    Aramini Jeff

    2006-04-01

    Full Text Available Abstract Background An extensive West Nile virus surveillance program of dead birds, mosquitoes, horses, and human infection has been launched as a result of West Nile virus first being reported in Canada in 2001. Some desktop and web GIS have been applied to West Nile virus dead bird surveillance. There have been urgent needs for a comprehensive GIS services and real-time surveillance. Results A pilot system was developed to integrate real-time surveillance, real-time GIS, and Open GIS technology in order to enhance West Nile virus dead bird surveillance in Canada. Driven and linked by the newly developed real-time web GIS technology, this integrated real-time surveillance system includes conventional real-time web-based surveillance components, integrated real-time GIS components, and integrated Open GIS components. The pilot system identified the major GIS functions and capacities that may be important to public health surveillance. The six web GIS clients provide a wide range of GIS tools for public health surveillance. The pilot system has been serving Canadian national West Nile virus dead bird surveillance since 2005 and is adaptable to serve other disease surveillance. Conclusion This pilot system has streamlined, enriched and enhanced national West Nile virus dead bird surveillance in Canada, improved productivity, and reduced operation cost. Its real-time GIS technology, static map technology, WMS integration, and its integration with non-GIS real-time surveillance system made this pilot system unique in surveillance and public health GIS.

  15. Implementation of condition-dependent probabilistic risk assessment using surveillance data on passive components

    International Nuclear Information System (INIS)

    Lewandowski, Radoslaw; Denning, Richard; Aldemir, Tunc; Zhang, Jinsuo

    2016-01-01

    Highlights: • Condition-dependent probabilistic risk assessment (PRA). • Time-dependent characterization of plant-specific risk. • Containment bypass involving in secondary system piping and SCC in SG tubes. - Abstract: A great deal of surveillance data are collected for a nuclear power plant that reflect the changing condition of the plant as it ages. Although surveillance data are used to determine failure probabilities of active components for the plant’s probabilistic risk assessment (PRA) and to indicate the need for maintenance activities, they are not used in a structured manner to characterize the evolving risk of the plant. The present study explores the feasibility of using a condition-dependent PRA framework that takes a first principles approach to modeling the progression of degradation mechanisms to characterize evolving risk, periodically adapting the model to account for surveillance results. A case study is described involving a potential containment bypass accident sequence due to the progression of flow-accelerated corrosion in secondary system piping and stress corrosion cracking of steam generator tubes. In this sequence, a steam line break accompanied by failure to close of a main steam isolation valve results in depressurization of the steam generator and induces the rupture of one or more faulted steam generator tubes. The case study indicates that a condition-dependent PRA framework might be capable of providing early identification of degradation mechanisms important to plant risk.

  16. The Acceptability and Feasibility of Implementing a Bio-Behavioral Enhanced Surveillance Tool for Sexually Transmitted Infections in England: Mixed-Methods Study.

    Science.gov (United States)

    Wayal, Sonali; Reid, David; Blomquist, Paula B; Weatherburn, Peter; Mercer, Catherine H; Hughes, Gwenda

    2018-05-04

    Sexually transmitted infection (STI) surveillance is vital for tracking the scale and pattern of epidemics; however, it often lacks data on the underlying drivers of STIs. This study aimed to assess the acceptability and feasibility of implementing a bio-behavioral enhanced surveillance tool, comprising a self-administered Web-based survey among sexual health clinic attendees, as well as linking this to their electronic health records (EHR) held in England's national STI surveillance system. Staff from 19 purposively selected sexual health clinics across England and men who have sex with men and black Caribbeans, because of high STI burden among these groups, were interviewed to assess the acceptability of the proposed bio-behavioral enhanced surveillance tool. Subsequently, sexual health clinic staff invited all attendees to complete a Web-based survey on drivers of STI risk using a study tablet or participants' own digital device. They recorded the number of attendees invited and participants' clinic numbers, which were used to link survey data to the EHR. Participants' online consent was obtained, separately for survey participation and linkage. In postimplementation phase, sexual health clinic staff were reinterviewed to assess the feasibility of implementing the bio-behavioral enhanced surveillance tool. Acceptability and feasibility of implementing the bio-behavioral enhanced surveillance tool were assessed by analyzing these qualitative and quantitative data. Prior to implementation of the bio-behavioral enhanced surveillance tool, sexual health clinic staff and attendees emphasized the importance of free internet/Wi-Fi access, confidentiality, and anonymity for increasing the acceptability of the bio-behavioral enhanced surveillance tool among attendees. Implementation of the bio-behavioral enhanced surveillance tool across sexual health clinics varied considerably and was influenced by sexual health clinics' culture of prioritization of research and

  17. Falling-incident detection and throughput enhancement in a multi-camera video-surveillance system.

    Science.gov (United States)

    Shieh, Wann-Yun; Huang, Ju-Chin

    2012-09-01

    For most elderly, unpredictable falling incidents may occur at the corner of stairs or a long corridor due to body frailty. If we delay to rescue a falling elder who is likely fainting, more serious consequent injury may occur. Traditional secure or video surveillance systems need caregivers to monitor a centralized screen continuously, or need an elder to wear sensors to detect falling incidents, which explicitly waste much human power or cause inconvenience for elders. In this paper, we propose an automatic falling-detection algorithm and implement this algorithm in a multi-camera video surveillance system. The algorithm uses each camera to fetch the images from the regions required to be monitored. It then uses a falling-pattern recognition algorithm to determine if a falling incident has occurred. If yes, system will send short messages to someone needs to be noticed. The algorithm has been implemented in a DSP-based hardware acceleration board for functionality proof. Simulation results show that the accuracy of falling detection can achieve at least 90% and the throughput of a four-camera surveillance system can be improved by about 2.1 times. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  18. Present status of metrology of electro-optical surveillance systems

    Science.gov (United States)

    Chrzanowski, K.

    2017-10-01

    There has been a significant progress in equipment for testing electro-optical surveillance systems over the last decade. Modern test systems are increasingly computerized, employ advanced image processing and offer software support in measurement process. However, one great challenge, in form of relative low accuracy, still remains not solved. It is quite common that different test stations, when testing the same device, produce different results. It can even happen that two testing teams, while working on the same test station, with the same tested device, produce different results. Rapid growth of electro-optical technology, poor standardization, limited metrology infrastructure, subjective nature of some measurements, fundamental limitations from laws of physics, tendering rules and advances in artificial intelligence are major factors responsible for such situation. Regardless, next decade should bring significant improvements, since improvement in measurement accuracy is needed to sustain fast growth of electro-optical surveillance technology.

  19. A Novel Surveillance System Applied in Civil Airport

    Directory of Open Access Journals (Sweden)

    Sun Hua Bo

    2016-01-01

    Full Text Available Conventional security monitoring of civil airport usually uses a fixed camera to acquire images. There are several problems with performance including difficulties introduced in the information transmission, storage, and analysis of the process. Insect compound eyes offer unique advantages for moving target capture and these have attracted the attention of many researchers in recent years. This paper contributes to this research by proposing a new surveillance system applied in civil airport. We discuss the finished bionic structure of the system, the development of the bionic control circuit, and introduce the proposed mathematical model of bionic compound eyes for data acquisition and image mosaic. Image matching for large view is also illustrated with different conditions. This mode and algorithm effectively achieve safety surveillance of airport with large field of view and high real-time processing.

  20. An optimal beam alignment method for large-scale distributed space surveillance radar system

    Science.gov (United States)

    Huang, Jian; Wang, Dongya; Xia, Shuangzhi

    2018-06-01

    Large-scale distributed space surveillance radar is a very important ground-based equipment to maintain a complete catalogue for Low Earth Orbit (LEO) space debris. However, due to the thousands of kilometers distance between each sites of the distributed radar system, how to optimally implement the Transmitting/Receiving (T/R) beams alignment in a great space using the narrow beam, which proposed a special and considerable technical challenge in the space surveillance area. According to the common coordinate transformation model and the radar beam space model, we presented a two dimensional projection algorithm for T/R beam using the direction angles, which could visually describe and assess the beam alignment performance. Subsequently, the optimal mathematical models for the orientation angle of the antenna array, the site location and the T/R beam coverage are constructed, and also the beam alignment parameters are precisely solved. At last, we conducted the optimal beam alignment experiments base on the site parameters of Air Force Space Surveillance System (AFSSS). The simulation results demonstrate the correctness and effectiveness of our novel method, which can significantly stimulate the construction for the LEO space debris surveillance equipment.

  1. Surveillance for travel-related disease--GeoSentinel Surveillance System, United States, 1997-2011.

    Science.gov (United States)

    Harvey, Kira; Esposito, Douglas H; Han, Pauline; Kozarsky, Phyllis; Freedman, David O; Plier, D Adam; Sotir, Mark J

    2013-07-19

    In 2012, the number of international tourist arrivals worldwide was projected to reach a new high of 1 billion arrivals, a 48% increase from 674 million arrivals in 2000. International travel also is increasing among U.S. residents. In 2009, U.S. residents made approximately 61 million trips outside the country, a 5% increase from 1999. Travel-related morbidity can occur during or after travel. Worldwide, 8% of travelers from industrialized to developing countries report becoming ill enough to seek health care during or after travel. Travelers have contributed to the global spread of infectious diseases, including novel and emerging pathogens. Therefore, surveillance of travel-related morbidity is an essential component of global public health surveillance and will be of greater importance as international travel increases worldwide. September 1997-December 2011. GeoSentinel is a clinic-based global surveillance system that tracks infectious diseases and other adverse health outcomes in returned travelers, foreign visitors, and immigrants. GeoSentinel comprises 54 travel/tropical medicine clinics worldwide that electronically submit demographic, travel, and clinical diagnosis data for all patients evaluated for an illness or other health condition that is presumed to be related to international travel. Clinical information is collected by physicians with expertise or experience in travel/tropical medicine. Data collected at all sites are entered electronically into a database, which is housed at and maintained by CDC. The GeoSentinel network membership program comprises 235 additional clinics in 40 countries on six continents. Although these network members do not report surveillance data systematically, they can report unusual or concerning diagnoses in travelers and might be asked to perform enhanced surveillance in response to specific health events or concerns. During September 1997-December 2011, data were collected on 141,789 patients with confirmed or

  2. Food and water radioactivity surveillance system in Romania

    International Nuclear Information System (INIS)

    Cucu, A.; Gheorghe, R.; May, C.; Barbu, R.

    2008-01-01

    Full text: Justification: Food and water radioactivity content are closely related both to natural radioactivity and also generated by contamination due to anthropic nuclear activities. Consequently, in accordance with the European Union acquis and World Health Organization recommendation, surveillance systems were operationalized in many European countries. According to the national Romanian derived legislation the public health authorities are responsible for organizing and coordination of the national surveillance system for water and food radioactivity and their health related effects. Objectives: Description of the levels and type of radioactivity of drinking water and main foodstuffs and their contribution to the Romanian population exposure in order to elaborate appropriate public health interventions. Method: The gross parameters, alpha and beta, have been used for screening surveillance of drinking water sources indeed for potable purposes in order to identify those that could exceed the total indicative dose of 0.1 mSv/year. The food surveillance was focused on the main foodstuffs including milk, meat, fish, eggs, bread, potatoes, root vegetables (mainly carrots), leafy vegetables (mainly cabbage), fruits, and canteen menu, controlled for presence and level of radioactivity for 137 Cs, 90 Sr, 226 Ra, 210 Po and 40 K. Nuclear facility related monitoring for areas as nuclear power plant Cernavoda (type HWR-CANDU) and for regions with activities of extraction and fabrication of uranium fuel includes monitoring of radioactivity for: environmental deposit levels, surface waters, spontaneous vegetation, drinking water and foodstuffs. Results: 1) The water radioactivity surveillance results, mapped by administrative borders of the national territory, reveal that parameters of drinking water complies both with Drinking Water Directive 98/83 EC and WHO recommandation/2004; 2) For food stuff radioactivity: a) Mean registered values fully comply with reference for

  3. Final report : mobile surveillance and wireless communication systems field operational test. Volume 1, Executive summary

    Science.gov (United States)

    1999-03-01

    This study focused on assessing the application of traffic monitoring and management systems which use transportable surveillance and ramp meter trailers, video image processors, and wireless communications. The mobile surveillance and wireless commu...

  4. Evaluating safety management system implementation

    International Nuclear Information System (INIS)

    Preuss, M.

    2009-01-01

    Canada is committed to not only maintaining, but also improving upon our record of having one of the safest aviation systems in the world. The development, implementation and maintenance of safety management systems is a significant step towards improving safety performance. Canada is considered a world leader in this area and we are fully engaged in implementation. By integrating risk management systems and business practices, the aviation industry stands to gain better safety performance with less regulatory intervention. These are important steps towards improving safety and enhancing the public's confidence in the safety of Canada's aviation system. (author)

  5. Development of Compact Surveillance and Monitoring System `COSMOS`

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Hironobu; Mukaiyama, Takehiko [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1999-03-01

    The Compact Surveillance and Monitoring System (COSMOS) was developed by the Japan Atomic Energy Research Institute (JAERI) for the International Atomic Energy Agency (IAEA) as a safeguards surveillance system under the JASPAS (Japan Support Programme for Agency Safeguards) with the collaboration of the Sony Corporation. It was intended as a direct replacement to the Twin Minolta film camera system. The COSMOS system can operate with a self-contained battery, record 30,000 scenes with an 8 mm video cassette tape and operate continuously for three months without human intervention. It can also operate by AC power supply for more than three months, and record 45,000 scenes in an 8 mm video cassette tape. The COSMOS system consists of two units, one is the Recording Unit and the other is the Setup/Review Unit. The Recording Unit consists of a main frame, four modules and a tamperproof housing. The four modules are a small CCD (Charge Coupled Device) camera with an auto-iris lens and a specific VTR (Video Tape Recorder), a video frame memory module, a system control module, and a DC or an AC power module. Currently, the COSMOS is the only safeguards video surveillance system without the need of external power supply for three months. In 1992 thirteen COSMOS units were successfully tested for the reliability by both the IAEA and the JAERI. None of mechanical failure was observed. On the one hand, the battery operation tests using four units were successfully carried out with 5 minutes time interval for three months. Three units were also tested in the field and no failure was observed. The COSMOS was accepted as the routine-use device for international safeguards by the IAEA in August 1993. The total of 90 units were purchased by the IAEA from the manufacturer, SONY, and also several units were purchased by the Science and Technology Agency (STA) of Japan for the STA/IAEA joint-use in Japan. (author)

  6. Development of Compact Surveillance and Monitoring System 'COSMOS'

    International Nuclear Information System (INIS)

    Ogawa, Hironobu; Mukaiyama, Takehiko

    1999-03-01

    The Compact Surveillance and Monitoring System (COSMOS) was developed by the Japan Atomic Energy Research Institute (JAERI) for the International Atomic Energy Agency (IAEA) as a safeguards surveillance system under the JASPAS (Japan Support Programme for Agency Safeguards) with the collaboration of the Sony Corporation. It was intended as a direct replacement to the Twin Minolta film camera system. The COSMOS system can operate with a self-contained battery, record 30,000 scenes with an 8 mm video cassette tape and operate continuously for three months without human intervention. It can also operate by AC power supply for more than three months, and record 45,000 scenes in an 8 mm video cassette tape. The COSMOS system consists of two units, one is the Recording Unit and the other is the Setup/Review Unit. The Recording Unit consists of a main frame, four modules and a tamperproof housing. The four modules are a small CCD (Charge Coupled Device) camera with an auto-iris lens and a specific VTR (Video Tape Recorder), a video frame memory module, a system control module, and a DC or an AC power module. Currently, the COSMOS is the only safeguards video surveillance system without the need of external power supply for three months. In 1992 thirteen COSMOS units were successfully tested for the reliability by both the IAEA and the JAERI. None of mechanical failure was observed. On the one hand, the battery operation tests using four units were successfully carried out with 5 minutes time interval for three months. Three units were also tested in the field and no failure was observed. The COSMOS was accepted as the routine-use device for international safeguards by the IAEA in August 1993. The total of 90 units were purchased by the IAEA from the manufacturer, SONY, and also several units were purchased by the Science and Technology Agency (STA) of Japan for the STA/IAEA joint-use in Japan. (author)

  7. Autonomous mobile robotic system for supporting counterterrorist and surveillance operations

    Science.gov (United States)

    Adamczyk, Marek; Bulandra, Kazimierz; Moczulski, Wojciech

    2017-10-01

    Contemporary research on mobile robots concerns applications to counterterrorist and surveillance operations. The goal is to develop systems that are capable of supporting the police and special forces by carrying out such operations. The paper deals with a dedicated robotic system for surveillance of large objects such as airports, factories, military bases, and many others. The goal is to trace unauthorised persons who try to enter to the guarded area, document the intrusion and report it to the surveillance centre, and then warn the intruder by sound messages and eventually subdue him/her by stunning through acoustic effect of great power. The system consists of several parts. An armoured four-wheeled robot assures required mobility of the system. The robot is equipped with a set of sensors including 3D mapping system, IR and video cameras, and microphones. It communicates with the central control station (CCS) by means of a wideband wireless encrypted system. A control system of the robot can operate autonomously, and under remote control. In the autonomous mode the robot follows the path planned by the CCS. Once an intruder has been detected, the robot can adopt its plan to allow tracking him/her. Furthermore, special procedures of treatment of the intruder are applied including warning about the breach of the border of the protected area, and incapacitation of an appropriately selected very loud sound until a patrol of guards arrives. Once getting stuck the robot can contact the operator who can remotely solve the problem the robot is faced with.

  8. Implementation of integrated management system

    International Nuclear Information System (INIS)

    Gaspar Junior, Joao Carlos A.; Fonseca, Victor Zidan da

    2007-01-01

    In present day exist quality assurance system, environment, occupational health and safety such as ISO9001, ISO14001 and OHSAS18001 and others standards will can create. These standards can be implemented and certified they guarantee one record system, quality assurance, documents control, operational control, responsibility definition, training, preparing and serve to emergency, monitoring, internal audit, corrective action, continual improvement, prevent of pollution, write procedure, reduce costs, impact assessment, risk assessment , standard, decree, legal requirements of municipal, state, federal and local scope. These procedure and systems when isolate applied cause many management systems and bureaucracy. Integration Management System reduce to bureaucracy, excess of documents, documents storage and conflict documents and easy to others standards implementation in future. The Integrated Management System (IMS) will be implemented in 2007. INB created a management group for implementation, this group decides planing, works, policy and advertisement. Legal requirements were surveyed, internal audits, pre-audits and audits were realized. INB is partially in accordance with ISO14001, OSHAS18001 standards. But very soon, it will be totally in accordance with this norms. Many studies and works were contracted to deal with legal requirements. This work have intention of show implementation process of ISO14001, OHSAS18001 and Integrated Management System on INB. (author)

  9. Redefining syndromic surveillance

    Directory of Open Access Journals (Sweden)

    Rebecca Katz

    2011-12-01

    Full Text Available With growing concerns about international spread of disease and expanding use of early disease detection surveillance methods, the field of syndromic surveillance has received increased attention over the last decade. The purpose of this article is to clarify the various meanings that have been assigned to the term syndromic surveillance and to propose a refined categorization of the characteristics of these systems. Existing literature and conference proceedings were examined on syndromic surveillance from 1998 to 2010, focusing on low- and middle-income settings. Based on the 36 unique definitions of syndromic surveillance found in the literature, five commonly accepted principles of syndromic surveillance systems were identified, as well as two fundamental categories: specific and non-specific disease detection. Ultimately, the proposed categorization of syndromic surveillance distinguishes between systems that focus on detecting defined syndromes or outcomes of interest and those that aim to uncover non-specific trends that suggest an outbreak may be occurring. By providing an accurate and comprehensive picture of this field’s capabilities, and differentiating among system types, a unified understanding of the syndromic surveillance field can be developed, encouraging the adoption, investment in, and implementation of these systems in settings that need bolstered surveillance capacity, particularly low- and middle-income countries.

  10. Sunglass detection method for automation of video surveillance system

    Science.gov (United States)

    Sikandar, Tasriva; Samsudin, Wan Nur Azhani W.; Hawari Ghazali, Kamarul; Mohd, Izzeldin I.; Fazle Rabbi, Mohammad

    2018-04-01

    Wearing sunglass to hide face from surveillance camera is a common activity in criminal incidences. Therefore, sunglass detection from surveillance video has become a demanding issue in automation of security systems. In this paper we propose an image processing method to detect sunglass from surveillance images. Specifically, a unique feature using facial height and width has been employed to identify the covered region of the face. The presence of covered area by sunglass is evaluated using facial height-width ratio. Threshold value of covered area percentage is used to classify the glass wearing face. Two different types of glasses have been considered i.e. eye glass and sunglass. The results of this study demonstrate that the proposed method is able to detect sunglasses in two different illumination conditions such as, room illumination as well as in the presence of sunlight. In addition, due to the multi-level checking in facial region, this method has 100% accuracy of detecting sunglass. However, in an exceptional case where fabric surrounding the face has similar color as skin, the correct detection rate was found 93.33% for eye glass.

  11. Wide area surveillance real-time motion detection systems

    CERN Document Server

    2014-01-01

    The book describes a system for visual surveillance using intelligent cameras. The camera uses robust techniques for detecting and tracking moving objects. The real time capture of the objects is then stored int he database. The tracking data stored in the database is analysed to study the camera view, detect and track objects, and study object behavior. These set of models provide a robust framework for coordinating the tracking of objects between overlapping and non-overlapping cameras, and recording the activity of objects detected by the system.

  12. Requirements and concepts for a nuclear plant surveillance and diagnostic system (NPSDS)

    International Nuclear Information System (INIS)

    Nicholson, P.J.; Lanning, D.D.

    1980-01-01

    An advanced plant surveillance and diagnostic system has been postulated for the purpose of aiding operator response to unanticipated plant upsets. The plant operator is described as an information processor that needs plant status information represented by symbolic outputs. These will be compatible with modern visual processing techniques, such as CRTs. Preferrred methods of estimating the state-of-the-plant and verifying measurements require on-line real-time models which are simple dynamical relationships based on energy and mass conservation laws. Implementation of on-line state estimation techniques using such models probably requires a distributed microcomputer system whose features are described. (auth)

  13. Real-time monitoring of school absenteeism to enhance disease surveillance: a pilot study of a mobile electronic reporting system.

    Science.gov (United States)

    Lawpoolsri, Saranath; Khamsiriwatchara, Amnat; Liulark, Wongwat; Taweeseneepitch, Komchaluch; Sangvichean, Aumnuyphan; Thongprarong, Wiraporn; Kaewkungwal, Jaranit; Singhasivanon, Pratap

    2014-05-12

    School absenteeism is a common source of data used in syndromic surveillance, which can eventually be used for early outbreak detection. However, the absenteeism reporting system in most schools, especially in developing countries, relies on a paper-based method that limits its use for disease surveillance or outbreak detection. The objective of this study was to develop an electronic real-time reporting system on school absenteeism for syndromic surveillance. An electronic (Web-based) school absenteeism reporting system was developed to embed it within the normal routine process of absenteeism reporting. This electronic system allowed teachers to update students' attendance status via mobile tablets. The data from all classes and schools were then automatically sent to a centralized database for further analysis and presentation, and for monitoring temporal and spatial patterns of absent students. In addition, the system also had a disease investigation module, which provided a link between absenteeism data from schools and local health centers, to investigate causes of fever among sick students. The electronic school absenteeism reporting system was implemented in 7 primary schools in Bangkok, Thailand, with total participation of approximately 5000 students. During May-October 2012 (first semester), the percentage of absentees varied between 1% and 10%. The peak of school absenteeism (sick leave) was observed between July and September 2012, which coincided with the peak of dengue cases in children aged 6-12 years being reported to the disease surveillance system. The timeliness of a reporting system is a critical function in any surveillance system. Web-based application and mobile technology can potentially enhance the use of school absenteeism data for syndromic surveillance and outbreak detection. This study presents the factors that determine the implementation success of this reporting system.

  14. Disturbance analysis and surveillance system scoping and feasibility system. Final report

    International Nuclear Information System (INIS)

    Dowling, E.F.; Benedict, B.J.; Snidow, N.L.

    1981-05-01

    This report summarizes the results of a disturbance analysis and surveillance system (DASS) scoping and feasibility study conducted by The Babcock and Wilcox Company, Burns and Roe, Incorporated, General Physics Corporation, and Duke Power Company for Sandia Laboratories and the US Department of Energy. The report addresses selection of DASS goals and functions, development of a design concept for a DASS based on monitoring the nuclear plant subsystem functions and states against predetermined targets, and creation of engineering procedures for the design and implementation of a DASS. The validity of the procedures is evaluated based on application to a subset of the DASS functions. It is concluded that the DASS design concept is a feasible, systematic, and modular approach to plant disturbance identification

  15. Electronic implementation of a novel surveillance paradigm for ventilator-associated events. Feasibility and validation

    NARCIS (Netherlands)

    Klein Klouwenberg, Peter M. C.; van Mourik, Maaike S. M.; Ong, David S. Y.; Horn, Janneke; Schultz, Marcus J.; Cremer, Olaf L.; Bonten, Marc J. M.

    2014-01-01

    Accurate surveillance of ventilator-associated pneumonia (VAP) is hampered by subjective diagnostic criteria. A novel surveillance paradigm for ventilator-associated events (VAEs) was introduced. To determine the validity of surveillance using the new VAE algorithm. Prospective cohort study in two

  16. How Can We Identify the Elimination of Infectious Diseases? Experience From an Active Measles Laboratory Surveillance System in the Republic of Korea.

    Science.gov (United States)

    Yang, Tae Un; Kang, Hae Ji; Eom, Hye Eun; Park, Young-Joon; Park, Ok; Kim, Su Jin; Nam, Jeong-Gu; Kim, Sung Soon; Jeong, Eun Kyeong

    2015-11-01

    Global efforts have markedly decreased the disease burden of vaccine-preventable diseases. Many countries have made considerable progress toward the elimination of measles. As elimination is approached, the very low incidence achieved by high vaccination coverage has underscored the need for a sensitive and timely surveillance system. In the Republic of Korea, an active laboratory surveillance system (ALSS) was implemented to supplement the existing passive surveillance system in 2006. The ALSS connects 5 major commercial laboratories and the national measles reference laboratory, where referred samples with positive or equivocal results are retested. Annually, from 2009 to 2013, 3714 suspected cases were detected through the ALSS, an expansion of 8- to 57-fold, compared with only the passive surveillance system. The ALSS, with its sensitivity and timeliness, is a reasonable strategy to supplement the existing measles surveillance system and to help identify the elimination of measles. © 2015 APJPH.

  17. An opportunity analysis system for space surveillance experiments with the MSX

    Science.gov (United States)

    Sridharan, Ramaswamy; Duff, Gary; Hayes, Tony; Wiseman, Andy

    1994-01-01

    The Mid-Course Space Experiment consists of a set of payloads on a satellite being designed and built under the sponsorship of Ballistic Missile Defense Office. The MSX satellite will conduct a series of measurements of phenomenology of backgrounds, missile targets, plumes and resident space objects (RSO's); and will engage in functional demonstrations in support of detection, acquisition and tracking for ballistic missile defense and space-based space surveillance missions. A complex satellite like the MSX has several constraints imposed on its operation by the sensors, the supporting instrumentation, power resources, data recording capability, communications and the environment in which all these operate. This paper describes the implementation of an opportunity and feasibility analysis system, developed at Lincoln Laboratory, Massachusetts Institute of Technology, specifically to support the experiments of the Principal Investigator for space-based surveillance.

  18. Rapid prototyping of an automated video surveillance system: a hardware-software co-design approach

    Science.gov (United States)

    Ngo, Hau T.; Rakvic, Ryan N.; Broussard, Randy P.; Ives, Robert W.

    2011-06-01

    FPGA devices with embedded DSP and memory blocks, and high-speed interfaces are ideal for real-time video processing applications. In this work, a hardware-software co-design approach is proposed to effectively utilize FPGA features for a prototype of an automated video surveillance system. Time-critical steps of the video surveillance algorithm are designed and implemented in the FPGAs logic elements to maximize parallel processing. Other non timecritical tasks are achieved by executing a high level language program on an embedded Nios-II processor. Pre-tested and verified video and interface functions from a standard video framework are utilized to significantly reduce development and verification time. Custom and parallel processing modules are integrated into the video processing chain by Altera's Avalon Streaming video protocol. Other data control interfaces are achieved by connecting hardware controllers to a Nios-II processor using Altera's Avalon Memory Mapped protocol.

  19. The Health and Occupation Research Network: An Evolving Surveillance System.

    Science.gov (United States)

    Carder, Melanie; Hussey, Louise; Money, Annemarie; Gittins, Matthew; McNamee, Roseanne; Stocks, Susan Jill; Sen, Dil; Agius, Raymond M

    2017-09-01

    Vital to the prevention of work-related ill-health (WRIH) is the availability of good quality data regarding WRIH burden and risks. Physician-based surveillance systems such as The Health and Occupation Research (THOR) network in the UK are often established in response to limitations of statutory, compensation-based systems for addressing certain epidemiological aspects of disease surveillance. However, to fulfil their purpose, THOR and others need to have methodologic rigor in capturing and ascertaining cases. This article describes how data collected by THOR and analogous systems can inform WRIH incidence, trends, and other determinants. An overview of the different strands of THOR research is provided, including methodologic advancements facilitated by increased data quantity/quality over time and the value of the research outputs for informing Government and other policy makers. In doing so, the utility of data collected by systems such as THOR to address a wide range of research questions, both in relation to WRIH and to wider issues of public and social health, is demonstrated.

  20. Improvements for optical surveillance systems in international safeguards

    International Nuclear Information System (INIS)

    Richter, B.; Stein, G.; Neumann, G.; Gaertner, K.J.; Whichello, J.N.

    1988-01-01

    Within the next few years, a transition from film camera systems to video surveillance systems will take place in international safeguards. In order to maintain the indispensable requirements of reliability and authentication, development and tests continued under the Federal Republic of Germany Support Programme of video components for IAEA safeguards applications. The prototype of a tamper resistant TV-link was developed under Task D.12/4/. A field test of the TV-link is in preparation using a production model suitable for multiplexed TV applications. The test will utilize an Agency owned, multiplexed TV system. An evaluation of the tamper resistant TV-link is given. After a successful field trial of the prototype Solid State Video Memory (SSVM-516) under task D.14 a production model has been developed under Task D.17. Several operating modes are envisaged, depending on whether it will be used in an on-site video surveillance system or in a video review station. The concept and technical features, including an explanation of the function of the video memory, are discussed

  1. The Health and Occupation Research Network: An Evolving Surveillance System

    Directory of Open Access Journals (Sweden)

    Melanie Carder

    2017-09-01

    Full Text Available Vital to the prevention of work-related ill-health (WRIH is the availability of good quality data regarding WRIH burden and risks. Physician-based surveillance systems such as The Health and Occupation Research (THOR network in the UK are often established in response to limitations of statutory, compensation-based systems for addressing certain epidemiological aspects of disease surveillance. However, to fulfil their purpose, THOR and others need to have methodologic rigor in capturing and ascertaining cases. This article describes how data collected by THOR and analogous systems can inform WRIH incidence, trends, and other determinants. An overview of the different strands of THOR research is provided, including methodologic advancements facilitated by increased data quantity/quality over time and the value of the research outputs for informing Government and other policy makers. In doing so, the utility of data collected by systems such as THOR to address a wide range of research questions, both in relation to WRIH and to wider issues of public and social health, is demonstrated.

  2. The utility of information collected by occupational disease surveillance systems.

    Science.gov (United States)

    Money, A; Carder, M; Hussey, L; Agius, R M

    2015-11-01

    The Health and Occupation Research (THOR) network in the UK and the Republic of Ireland (ROI) is an integrated system of surveillance schemes collecting work-related ill-health (WRIH) data since 1989. In addition to providing information about disease incidence, trends in incidence and the identification of new hazards, THOR also operates an ad hoc data enquiry service enabling interested parties to request information about cases of WRIH reported to THOR. To examine requests for information made to a network of surveillance schemes for WRIH in the UK. Analysis via SPSS of data requests received by THOR between 2002 and 2014. A total of 631 requests were received by THOR between 2002 and 2014. Requests were predominantly submitted by participating THOR physicians (34%) and the main THOR funder-the UK Health & Safety Executive (HSE) (31%). The majority (67%) of requests were for information about work-related respiratory or skin disease with relatively few requests for other diagnoses, such as musculoskeletal or mental ill-health. Requests frequently related to a specific industry and/or occupation (42%) and/or a specific causal agent (58%). Data collected by occupational disease surveillance systems such as THOR are an extremely useful source of information, the use of which extends beyond informing government on disease incidence and trends in incidence. The data collected provide a framework that can assist a wide range of enquirers with clinical diagnoses, identification of suspected causative agents/exposures and to highlight growing risks in particular industrial and occupational sectors. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Situation exploration in a persistent surveillance system with multidimensional data

    Science.gov (United States)

    Habibi, Mohammad S.

    2013-03-01

    There is an emerging need for fusing hard and soft sensor data in an efficient surveillance system to provide accurate estimation of situation awareness. These mostly abstract, multi-dimensional and multi-sensor data pose a great challenge to the user in performing analysis of multi-threaded events efficiently and cohesively. To address this concern an interactive Visual Analytics (VA) application is developed for rapid assessment and evaluation of different hypotheses based on context-sensitive ontology spawn from taxonomies describing human/human and human/vehicle/object interactions. A methodology is described here for generating relevant ontology in a Persistent Surveillance System (PSS) and demonstrates how they can be utilized in the context of PSS to track and identify group activities pertaining to potential threats. The proposed VA system allows for visual analysis of raw data as well as metadata that have spatiotemporal representation and content-based implications. Additionally in this paper, a technique for rapid search of tagged information contingent to ranking and confidence is explained for analysis of multi-dimensional data. Lastly the issue of uncertainty associated with processing and interpretation of heterogeneous data is also addressed.

  4. Integrated Monitoring and Surveillance System demonstration project. Phase 2 accomplishments

    International Nuclear Information System (INIS)

    Aumeier, S.E.; Walters, B.G.; Singleterry, R.C.

    1997-01-01

    The paper presents the results of the Integrated Monitoring and Surveillance System (IMSS) demonstration project Phase 2 efforts. the rationale behind IMSS development is reviewed and progress in each of the 5 basic tasks is detailed. Significant results include further development of the data acquisition system and procurement of necessary hardware/software, options and associated costs for plutonium canning systems and gloveboxes, initiation of facility modifications, determination of possibly affected facility documentation, results from sensor system trade study, and preliminary storage configuration designs. Resources invested during Phase 1 and Phase 2 are summarized and budgetary requirements for completion of Phase 3 presented. The results show that the IMSS demonstration project team has met and in many cases exceeded the commitments made for Phase 2 deliverables

  5. Current French system of post-marketing drug surveillance.

    Science.gov (United States)

    Albengres, E; Gauthier, F; Tillement, J P

    1990-07-01

    The French system of drug surveillance is characterized by several original features: thirty regional centres are selected to cover all of France to collect, analyze and enter the adverse drug events in the national data bank. The system is based on a bank of well documented files submitted to a decision of imputation; the report of severe events by prescribers is mandatory; cases are collected either by spontaneous reporting (routine) or by direct request (intensive validation study); the system is being involved in studies of epidemiological type as carried out by the national system of health or a few societies of medicine as well as by the centres themselves in cooperative works on defined populations.

  6. SCHISTOSOMIASIS: GEOSPATIAL SURVEILLANCE AND RESPONSE SYSTEMS IN SOUTHEAST ASIA

    Directory of Open Access Journals (Sweden)

    J. Malone

    2016-10-01

    Full Text Available Geographic information system (GIS and remote sensing (RS from Earth-observing satellites offer opportunities for rapid assessment of areas endemic for vector-borne diseases including estimates of populations at risk and guidance to intervention strategies. This presentation deals with GIS and RS applications for the control of schistosomiasis in China and the Philippines. It includes large-scale risk mapping including identification of suitable habitats for Oncomelania hupensis, the intermediate host snail of Schistosoma japonicum. Predictions of infection risk are discussed with reference to ecological transformations and the potential impact of climate change and the potential for long-term temperature increases in the North as well as the impact on rivers, lakes and water resource developments. Potential integration of geospatial mapping and modeling in schistosomiasis surveillance and response systems in Asia within Global Earth Observation System of Systems (GEOSS guidelines in the health societal benefit area is discussed.

  7. The Nigerian health care system: Need for integrating adequate medical intelligence and surveillance systems

    Directory of Open Access Journals (Sweden)

    Menizibeya Osain Welcome

    2011-01-01

    Full Text Available Objectives : As an important element of national security, public health not only functions to provide adequate and timely medical care but also track, monitor, and control disease outbreak. The Nigerian health care had suffered several infectious disease outbreaks year after year. Hence, there is need to tackle the problem. This study aims to review the state of the Nigerian health care system and to provide possible recommendations to the worsening state of health care in the country. To give up-to-date recommendations for the Nigerian health care system, this study also aims at reviewing the dynamics of health care in the United States, Britain, and Europe with regards to methods of medical intelligence/surveillance. Materials and Methods : Databases were searched for relevant literatures using the following keywords: Nigerian health care, Nigerian health care system, and Nigerian primary health care system. Additional keywords used in the search were as follows: United States (OR Europe health care dynamics, Medical Intelligence, Medical Intelligence systems, Public health surveillance systems, Nigerian medical intelligence, Nigerian surveillance systems, and Nigerian health information system. Literatures were searched in scientific databases Pubmed and African Journals OnLine. Internet searches were based on Google and Search Nigeria. Results : Medical intelligence and surveillance represent a very useful component in the health care system and control diseases outbreak, bioattack, etc. There is increasing role of automated-based medical intelligence and surveillance systems, in addition to the traditional manual pattern of document retrieval in advanced medical setting such as those in western and European countries. Conclusion : The Nigerian health care system is poorly developed. No adequate and functional surveillance systems are developed. To achieve success in health care in this modern era, a system well grounded in routine

  8. Intelligent fractions learning system: implementation

    CSIR Research Space (South Africa)

    Smith, Andrew C

    2011-05-01

    Full Text Available Conference Proceedings Paul Cunningham and Miriam Cunningham (Eds) IIMC International Information Management Corporation, 2011 ISBN: 978-1-905824-24-3 An Intelligent Fractions Learning System: Implementation Andrew Cyrus SMITH1, Teemu H. LAINE2 1CSIR... to fractions. Our aim with the current research project is to extend the existing UFractions learning system to incorporate automatic data capturing. ?Intelligent UFractions? allows a teacher to remotely monitor the children?s progress during...

  9. EPICS system: RSX implementation issues

    International Nuclear Information System (INIS)

    Lahey, T.E.; Bartlett, J.F.; Bobbitt, J.S.; Kramper, B.J.; MacKinnon, B.A.; West, R.E.

    1984-02-01

    This paper presents implementation details of the Experimental Physics Interactive Control System (EPICS). EPICS is used to control accelerated particle beams for high-energy physics experiments at the Fermi National Accelerator Laboratory. The topics discussed are: interprocessor communication, support of beamline terminals and devices, resource management, mapping, various problems, some solutions to the problems, performance measurement, and modifications and extensions to RSX-11M. This paper is the third of three related papers on the EPICS system. The other two cover (1) the system overview and (2) the system structure and user interface

  10. Integrating malaria surveillance with climate data for outbreak detection and forecasting: the EPIDEMIA system.

    Science.gov (United States)

    Merkord, Christopher L; Liu, Yi; Mihretie, Abere; Gebrehiwot, Teklehaymanot; Awoke, Worku; Bayabil, Estifanos; Henebry, Geoffrey M; Kassa, Gebeyaw T; Lake, Mastewal; Wimberly, Michael C

    2017-02-23

    Early indication of an emerging malaria epidemic can provide an opportunity for proactive interventions. Challenges to the identification of nascent malaria epidemics include obtaining recent epidemiological surveillance data, spatially and temporally harmonizing this information with timely data on environmental precursors, applying models for early detection and early warning, and communicating results to public health officials. Automated web-based informatics systems can provide a solution to these problems, but their implementation in real-world settings has been limited. The Epidemic Prognosis Incorporating Disease and Environmental Monitoring for Integrated Assessment (EPIDEMIA) computer system was designed and implemented to integrate disease surveillance with environmental monitoring in support of operational malaria forecasting in the Amhara region of Ethiopia. A co-design workshop was held with computer scientists, epidemiological modelers, and public health partners to develop an initial list of system requirements. Subsequent updates to the system were based on feedback obtained from system evaluation workshops and assessments conducted by a steering committee of users in the public health sector. The system integrated epidemiological data uploaded weekly by the Amhara Regional Health Bureau with remotely-sensed environmental data freely available from online archives. Environmental data were acquired and processed automatically by the EASTWeb software program. Additional software was developed to implement a public health interface for data upload and download, harmonize the epidemiological and environmental data into a unified database, automatically update time series forecasting models, and generate formatted reports. Reporting features included district-level control charts and maps summarizing epidemiological indicators of emerging malaria outbreaks, environmental risk factors, and forecasts of future malaria risk. Successful implementation and

  11. Radiation protection in nuclear facilities. The Caise environmental surveillance system

    International Nuclear Information System (INIS)

    Witt, H. de; Voelz, E.

    1995-01-01

    The Computer Aided Surveillance System for the Environment of Nuclear Installations (Caise) has been designed for permanent surveillance of the environment of nuclear installations under normal operating conditions and for unusual events on the basis of radiological and meteorological measured data. In normal operation, the data measured on line are fed to the system by way of a defined interface, while off-line data can be entered manually in the dialog mode. Subsequently, the measured data are stored, filed away, and secured. Short-time dispersion factors can be calculated permanently in the on-line mode, while the off-line mode allows short-term and long-term dispersions to be calculated for randomly selectable periods of time under the General Administrative Rule of Sec. 45 of the German Radiation Protection Ordinance. The corresponding dose distributions in the environment of the plant can be determined next. Under conditions of increased emissions (accidents, failures), Caise assists in quick decision-making by its capacity for real-time dispersion calculations including current on-line and off-line emission sample measurements. In this way, the contributions by various different exposure pathways to the calculated dose can be determined more accurately. (orig.) [de

  12. System for implement draft reduction

    DEFF Research Database (Denmark)

    2008-01-01

    Abstract of WO 2008095503  (A1) There is disclosed a system and method of reducing draft forces when working soil with agricultural soil working implements (206, 211) creating draft forces, the soil working implements (208, 206, 211) beingoperable connectable to a frame (204, 304, 404, 504, 604......, the second part of the width comprising an other part of said width (212) than the first part (222), so as e.g. to reduce draft forces compared to working both first and second parts at the same time....

  13. Integrated monitoring and surveillance system demonstration project: Phase I accomplishments

    International Nuclear Information System (INIS)

    Aumeier, S.E.; Walters, B.G.; Crawford, D.C.

    1997-01-01

    The authors present the results of the Integrated Monitoring and Surveillance System (IMSS) demonstration project Phase I efforts. The rationale behind IMSS development is reviewed and progress in each of the 5 basic tasks is detailed. Significant results include decisions to use Echelon LonWorks networking protocol and Microsoft Access for the data system needs, a preliminary design for the plutonium canning system glovebox, identification of facilities and materials available for the demonstration, determination of possibly affected facility documentation, and a preliminary list of available sensor technologies. Recently imposed changes in the overall project schedule and scope are also discussed and budgetary requirements for competition of Phase II presented. The results show that the IMSS demonstration project team has met and in many cases exceeded the commitments made for Phase I deliverables

  14. Prototyping of a Situation Awareness System in the Maritime Surveillance

    International Nuclear Information System (INIS)

    Handayani, D O D; Shah, A; Sediono, W

    2013-01-01

    This paper discusses about the design of a Situation Awareness (SA) system to support vessel crews and control room operators in improving the decision making process. The architecture of the system is ontology based. The vessel crews and control room operators may face a loss of SA. They may have limited cognitive abilities which make it difficult to make a decision in a high stress level, short time availability and continuously evolving situation with incomplete information. In this work, we describe the application of Semantic Web Rule Language to represent corresponding knowledge in the maritime surveillance domain. The result of this research will demonstrate that an ontology based system can be used to remodel the information into a meaningful and valuable form to predict the future states of SA and improve the decision making process

  15. Establishment, test and evaluation of a prototype volcano surveillance system

    Science.gov (United States)

    Ward, P. L.; Eaton, J. P.; Endo, E.; Harlow, D.; Marquez, D.; Allen, R.

    1973-01-01

    A volcano-surveillance system utilizing 23 multilevel earthquake counters and 6 biaxial borehole tiltmeters is being installed and tested on 15 volcanoes in 4 States and 4 foreign countries. The purpose of this system is to give early warning when apparently dormant volcanoes are becoming active. The data are relayed through the ERTS-Data Collection System to Menlo Park for analysis. Installation was completed in 1972 on the volcanoes St. Augustine and Iliamna in Alaska, Kilauea in Hawaii, Baker, Rainier and St. Helens in Washington, Lassen in California, and at a site near Reykjavik, Iceland. Installation continues and should be completed in April 1973 on the volcanoes Santiaguito, Fuego, Agua and Pacaya in Guatemala, Izalco in El Salvador and San Cristobal, Telica and Cerro Negro in Nicaragua.

  16. Surveillance and early warning systems of infectious disease in China: From 2012 to 2014.

    Science.gov (United States)

    Zhang, Honglong; Wang, Liping; Lai, Shengjie; Li, Zhongjie; Sun, Qiao; Zhang, Peng

    2017-07-01

    Appropriate surveillance and early warning of infectious diseases have very useful roles in disease control and prevention. In 2004, China established the National Notifiable Infectious Disease Surveillance System and the Public Health Emergency Event Surveillance System to report disease surveillance and events on the basis of data sources from the National Notifiable Infectious Disease Surveillance System, China Infectious Disease Automated-alert and Response System in this country. This study provided a descriptive summary and a data analysis, from 2012 to 2014, of these 3 key surveillance and early warning systems of infectious disease in China with the intent to provide suggestions for system improvement and perfection. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Developing a new syndromic surveillance system for the London 2012 Olympic and Paralympic Games.

    Science.gov (United States)

    Harcourt, S E; Fletcher, J; Loveridge, P; Bains, A; Morbey, R; Yeates, A; McCloskey, B; Smyth, B; Ibbotson, S; Smith, G E; Elliot, A J

    2012-12-01

    Syndromic surveillance is vital for monitoring public health during mass gatherings. The London 2012 Olympic and Paralympic Games represents a major challenge to health protection services and community surveillance. In response to this challenge the Health Protection Agency has developed a new syndromic surveillance system that monitors daily general practitioner out-of-hours and unscheduled care attendances. This new national system will fill a gap identified in the existing general practice-based syndromic surveillance systems by providing surveillance capability of general practice activity during evenings/nights, over weekends and public holidays. The system will complement and supplement the existing tele-health phone line, general practitioner and emergency department syndromic surveillance systems. This new national system will contribute to improving public health reassurance, especially to meet the challenges of the London 2012 Olympic and Paralympic Games.

  18. FCA containment and surveillance (C/S) system

    International Nuclear Information System (INIS)

    Ogawa, Hironobu; Mukaiyama, Takehiko; Yokota, Yasuhiro.

    1994-11-01

    The Fast Critical Assembly (FCA) facility of the Japan Atomic Energy Research Inst. (JAERI) is internationally recognized as one of the most sensitive facility in the world from the viewpoint of international safeguards, because the facility possesses a large amount of metallic uranium and metallic plutonium, which are needed to perform various physical experiments. These material are subject to frequent verifications by the inspectorate, the International Atomic Energy Agency (IAEA) and the domestic authority (Science and Technology Agency of Japan, STA). Those verifications require inspectors to access to these materials for measurements and applications of seals. Human resources increase of irradiations and restrictions on the freedom of physical experiments, that are inevitably associated with these inspection activities, have been a serious problem that causes significant burdens for all relating parties. To decrease these burdens without any confliction with the inspection goals, an advanced comprehensive system of containment and surveillance has been developed. The FCA Containment and Surveillance (C/S) System consists of tow independent subsystems, i. e. Portal Monitor (P/M) and Penetration Monitor(PN/M). In this system the internal wall of the reactor building is used as a part of containment for the safeguards purpose, which enables the portal, that is installed at the internal wall of the reactor building, to be used as an area for monitoring of any removal of nuclear material. A metal detector of high sensitivity has been selected for the system since all nuclear materials possessed by the FCA has metallic forms. The internal wall has several penetrations for utility purposes, which should also be monitored for the purpose of detecting any removal of nuclear material from the reactor core area. A penetration monitor system has been developed for this purpose. This report describes functions of the system and their operation procedures. (author)

  19. The South African national non-natural mortality surveillance system ...

    African Journals Online (AJOL)

    Journal Home > Vol 91, No 5 (2001) > ... Data entered into the system by mortuary staff were checked against a random sample of cases ... Lack of equipment, personnel resistance, and closure of some mortuaries prevented implementation in ...

  20. Complement: a key system for immune surveillance and homeostasis.

    Science.gov (United States)

    Ricklin, Daniel; Hajishengallis, George; Yang, Kun; Lambris, John D

    2010-09-01

    Nearly a century after the significance of the human complement system was recognized, we have come to realize that its functions extend far beyond the elimination of microbes. Complement acts as a rapid and efficient immune surveillance system that has distinct effects on healthy and altered host cells and foreign intruders. By eliminating cellular debris and infectious microbes, orchestrating immune responses and sending 'danger' signals, complement contributes substantially to homeostasis, but it can also take action against healthy cells if not properly controlled. This review describes our updated view of the function, structure and dynamics of the complement network, highlights its interconnection with immunity at large and with other endogenous pathways, and illustrates its multiple roles in homeostasis and disease.

  1. Implementation Research of CRM System

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    This paper firstly discusses the importance of impl em enting CRM (Costumer Relationship Management) in the information era, studies th e elementary theory of CRM, and the relationship between CRM and ERP(Enterprise Resource Planning). Then the present situation of application of CRM system in C hina is analyzed in details. Based on the actuality and development object in th e future of ChangSha Zoomlion Heavy Industry and Technology Development CO., LTD ., the objective of CRM implementation and organizat...

  2. Public health efforts to build a surveillance system for child maltreatment mortality: lessons learned for stakeholder engagement.

    Science.gov (United States)

    Smith, Lucia Rojas; Gibbs, Deborah; Wetterhall, Scott; Schnitzer, Patricia G; Farris, Tonya; Crosby, Alex E; Leeb, Rebecca T

    2011-01-01

    Reducing the number of largely preventable and tragic deaths due to child maltreatment (CM) requires an understanding of the magnitude of and risk factors for fatal CM and targeted research, policy, and prevention efforts. Public health surveillance offers an opportunity to improve our understanding of the problem of CM. In 2006, the Centers for Disease Control and Prevention (CDC) funded state public health agencies in California, Michigan, and Oregon to implement a model approach for routine and sustainable CM surveillance and evaluated the experience of those efforts. We describe the experiences of 3 state health agencies in building collaborations and partnerships with multiple stakeholders for CM surveillance. Qualitative, structured key informant interviews were carried out during site visits as part of an evaluation of a CDC-funded project to implement a model approach to CM surveillance. Key informants included system stakeholders from state health agencies, law enforcement, child protective services, the medical community, and child welfare advocacy groups in the 3 funded states. Factors that facilitated stakeholder engagement for CM surveillance included the following: streamlining and coordinating the work of Child Death Review Teams (CDRTs); demonstrating the value of surveillance to non-public health partners; codifying relationships with participating agencies; and securing the commitment of decision-makers. Legislative mandates were helpful in bringing key stakeholders together, but it was not sufficient to ensure sustained engagement. The engagement process yielded multiple benefits for the stakeholders including a deeper appreciation of the complexity of defining CM; a greater understanding of risk factors for CM; and enhanced guidance for prevention and control efforts. States considering or currently undertaking CM surveillance can glean useful insights from the experiences of these 3 states and apply them to their own efforts to engage

  3. Workers' health surveillance: implementation of the Directive 89/391/EEC in Europe

    NARCIS (Netherlands)

    Colosio, C.; Mandic-Rajcevic, S.; Godderis, L.; van der Laan, G.; Hulshof, C.; van Dijk, F.

    2017-01-01

    Background European Union (EU) Directive 89/391 addressed occupational health surveillance, which recommends to provide workers with `access to health surveillance at regular intervals', aiming to prevent work-related and occupational diseases. Aims To investigate how EU countries adopted this

  4. Implementing hospital-based surveillance for severe acute respiratory infections caused by influenza and other respiratory pathogens in New Zealand

    Directory of Open Access Journals (Sweden)

    Q Sue Huang

    2014-05-01

    Full Text Available Background: Recent experience with pandemic influenza A(H1N1pdm09 highlighted the importance of global surveillance for severe respiratory disease to support pandemic preparedness and seasonal influenza control. Improved surveillance in the southern hemisphere is needed to provide critical data on influenza epidemiology, disease burden, circulating strains and effectiveness of influenza prevention and control measures. Hospital-based surveillance for severe acute respiratory infection (SARI cases was established in New Zealand on 30 April 2012. The aims were to measure incidence, prevalence, risk factors, clinical spectrum and outcomes for SARI and associated influenza and other respiratory pathogen cases as well as to understand influenza contribution to patients not meeting SARI case definition. Methods/Design: All inpatients with suspected respiratory infections who were admitted overnight to the study hospitals were screened daily. If a patient met the World Health Organization’s SARI case definition, a respiratory specimen was tested for influenza and other respiratory pathogens. A case report form captured demographics, history of presenting illness, co-morbidities, disease course and outcome and risk factors. These data were supplemented from electronic clinical records and other linked data sources. Discussion: Hospital-based SARI surveillance has been implemented and is fully functioning in New Zealand. Active, prospective, continuous, hospital-based SARI surveillance is useful in supporting pandemic preparedness for emerging influenza A(H7N9 virus infections and seasonal influenza prevention and control.

  5. Multidisciplinary approach to successful implementation of production information system (PRISM)

    Energy Technology Data Exchange (ETDEWEB)

    Shariff, M.R.; Gopalakrishnan, S.G.; Francis, N. [and others

    1995-12-31

    A company wide corporate and regional production database supporting all production areas was envisaged critical to the current expansion within Petronas Carigali Sdn Bhd (PCSB). A multi disciplinary project team was thus formed to analyze the requirements prior to developing, testing, implementing and training users. PCSB has currently evolved into a mature E & P company on par with other E & P companies within the region. This expansion necessitates a common Production Information System for the efficient dissemination of vital Production Information for Production Surveillance, Reservoir Management, Reserve Assessment, Special Studies and Standardized Group-wide Reporting. This paper will discuss all the phases involved in the project which includes Systems Requirement Study, Data Migration, System Development, System Implementation and Post-Implementation Plan.

  6. A vision-based driver nighttime assistance and surveillance system based on intelligent image sensing techniques and a heterogamous dual-core embedded system architecture.

    Science.gov (United States)

    Chen, Yen-Lin; Chiang, Hsin-Han; Chiang, Chuan-Yen; Liu, Chuan-Ming; Yuan, Shyan-Ming; Wang, Jenq-Haur

    2012-01-01

    This study proposes a vision-based intelligent nighttime driver assistance and surveillance system (VIDASS system) implemented by a set of embedded software components and modules, and integrates these modules to accomplish a component-based system framework on an embedded heterogamous dual-core platform. Therefore, this study develops and implements computer vision and sensing techniques of nighttime vehicle detection, collision warning determination, and traffic event recording. The proposed system processes the road-scene frames in front of the host car captured from CCD sensors mounted on the host vehicle. These vision-based sensing and processing technologies are integrated and implemented on an ARM-DSP heterogamous dual-core embedded platform. Peripheral devices, including image grabbing devices, communication modules, and other in-vehicle control devices, are also integrated to form an in-vehicle-embedded vision-based nighttime driver assistance and surveillance system.

  7. GeoMedStat: an integrated spatial surveillance system to track air pollution and associated healthcare events

    Directory of Open Access Journals (Sweden)

    Fazlay S. Faruque

    2014-12-01

    Full Text Available Air pollutants, such as particulate matter with a diameter ≤2.5 microns (PM2.5 and ozone (O3, are known to exacerbate asthma and other respiratory diseases. An integrated surveillance system that tracks such air pollutants and associated disease incidence can assist in risk assessment, healthcare preparedness and public awareness. However, the implementation of such an integrated environmental health surveillance system is a challenge due to the disparate sources of many types of data and the implementation becomes even more complicated for a spatial and real-time system due to lack of standardised technological components and data incompatibility. In addition, accessing and utilising health data that are considered as Protected Health Information (PHI require maintaining stringent protocols, which have to be supported by the system. This paper aims to illustrate the development of a spatial surveillance system (GeoMedStat that is capable of tracking daily environmental pollutants along with both daily and historical patient encounter data. It utilises satellite data and the groundmonitor data from the US National Aeronautics and Space Administration (NASA and the US Environemental Protection Agenecy (EPA, rspectively as inputs estimating air pollutants and is linked to hospital information systems for accessing chief complaints and disease classification codes. The components, developmental methods, functionality of GeoMedStat and its use as a real-time environmental health surveillance system for asthma and other respiratory syndromes in connection with with PM2.5 and ozone are described. It is expected that the framework presented will serve as an example to others developing real-time spatial surveillance systems for pollutants and hospital visits.

  8. Surveillance of systemic autoimmune rheumatic diseases using administrative data.

    Science.gov (United States)

    Bernatsky, S; Lix, L; Hanly, J G; Hudson, M; Badley, E; Peschken, C; Pineau, C A; Clarke, A E; Fortin, P R; Smith, M; Bélisle, P; Lagace, C; Bergeron, L; Joseph, L

    2011-04-01

    There is growing interest in developing tools and methods for the surveillance of chronic rheumatic diseases, using existing resources such as administrative health databases. To illustrate how this might work, we used population-based administrative data to estimate and compare the prevalence of systemic autoimmune rheumatic diseases (SARDs) across three Canadian provinces, assessing for regional differences and the effects of demographic factors. Cases of SARDs (systemic lupus erythematosus, scleroderma, primary Sjogren's, polymyositis/dermatomyositis) were ascertained from provincial physician billing and hospitalization data. We combined information from three case definitions, using hierarchical Bayesian latent class regression models that account for the imperfect nature of each case definition. Using methods that account for the imperfect nature of both billing and hospitalization databases, we estimated the over-all prevalence of SARDs to be approximately 2-3 cases per 1,000 residents. Stratified prevalence estimates suggested similar demographic trends across provinces (i.e. greater prevalence in females-versus-males, and in persons of older age). The prevalence in older females approached or exceeded 1 in 100, which may reflect the high burden of primary Sjogren's syndrome in this group. Adjusting for demographics, there was a greater prevalence in urban-versus-rural settings. In our work, prevalence estimates had good face validity and provided useful information about potential regional and demographic variations. Our results suggest that surveillance of some rheumatic diseases using administrative data may indeed be feasible. Our work highlights the usefulness of using multiple data sources, adjusting for the error in each.

  9. REVIEW OF METHODS FOR THE SURVEILLANCE AND ACCESS CONTROL USING THE THERMAL IMAGING SYSTEM

    Directory of Open Access Journals (Sweden)

    Mate Krišto

    2016-12-01

    Full Text Available This paper presents methods for human detection for application in the field of national security in the context of state border surveillance. Except in the context of state border security, the presented methods can be applied to monitor other protected object and infrastructure such as ports and airports, power plants, water supply systems, oil pipelines, etc. Presented methods are based on use of thermal imaging systems for the human detection, recognition and identification. In addition to methods for the detection of persons, are presented and methods for face recognition and identification of the person. The use of such systems has special significance in the context of national security in the domain of timely detection of illegal crossing of state border or illegal movement near buildings, which are of special importance for national security such as traffic infrastructure facilities, power plants, military bases, especially in mountain or forests areas. In this context, thermal imaging has significant advantages over the optical camera surveillance systems because thermal imaging is robust to weather conditions and due to such an infrared thermal system can successfully applied in any weather conditions, or the periods of the day. Featured are procedures that has human detection results as well as a brief survey of specific implementation in terms of the use of infrared thermal imagers mounted on autonomous vehicles (AV and unmanned aerial vehicles (UAV. In addition to the above in this paper are described techniques and methods of face detection and human identification based on thermal image (thermogram.

  10. The design and evaluation of an antimicrobial resistance surveillance system for neonatal intensive care units in Iran.

    Science.gov (United States)

    Rezaei-Hachesu, Peyman; Samad-Soltani, Taha; Yaghoubi, Sajad; GhaziSaeedi, Marjan; Mirnia, Kayvan; Masoumi-Asl, Hossein; Safdari, Reza

    2018-07-01

    Neonatal intensive care units (NICUs) have complex patients in terms of their diagnoses and required treatments. Antimicrobial treatment is a common therapy for patients in NICUs. To solve problems pertaining to empirical therapy, antimicrobial stewardship programs have recently been introduced. Despite the success of these programs in terms of data collection, there is still inefficiency in terms of analyzing and reporting the data. Thus, to successfully implement these stewardship programs, the design of antimicrobial resistance (AMR) surveillance systems is recommended as a first step. As a result, this study aimed to design an AMR surveillance system for use in the NICUs in northwestern Iranian hospitals to cover these information gaps. The recommended system is compatible with the World Health Organization (WHO) guidelines. The business intelligence (BI) requirements were extracted in an interview with a product owner (PO) using a valid and reliable checklist. Following this, an AMR surveillance system was designed and evaluated in relation to user experiences via a user experience questionnaire (UEQ). Finally, an association analysis was performed on the database, and the results were reported by identifying the important multidrug resistances in the database. A customized software development methodology was proposed. The three major modules of the AMR surveillance are the data registry, dashboard, and decision support modules. The data registry module was implemented based on a three-tier architecture, and the Clinical Decision Support System (CDSS) and dashboard modules were designed based on the BI requirements of the Scrum product owner (PO). The mean values of UEQ measures were in a good range. This measures showed the suitable usability of the AMR surveillance system. Applying efficient software development methodologies allows for the systems' compatibility with users' opinions and requirements. In addition, the construction of interdisciplinary

  11. Smart Telerobotic Surveillance System via Internet with Reduced Time Delay

    Directory of Open Access Journals (Sweden)

    Ashesh Vasalya

    2012-09-01

    Full Text Available This work provides an imperial solution to the problems faced by man while enduring hazardous tasks like handling and disposal of nuclear wastes, monitoring nuclear power plants, mining operations etc .which have to be aborted if expertise group running it is unavailable or on a run. This paper presents a distributed platform that allows the special group of user to control a gadget (possibly a robot through internet as a medium. An advanced version of this technology is capable of transmitting graphic images and other surrounding information as required, via internet back to the user to facilitate the effective monitoring of the existent situation using appropriate software tools. The project uses the SRV-1 Mobile Surveillance Robot which is a fully integrated system standard designed and other related technology for surveillance purposes. It is driven via web browser using JAVA based control applications with live video feeds. Specialised user group will be given separate account from where they can control and monitor the system even when they are not present at the site. End user will be connected to the gadget (robot through a central server which acts as a single channel for both sending and receiving information. But the subject of remote control over the internet has some possible anomalies namely network freezing, delay between host and recipient, congested network and many others. This system enables asynchronous object passing so that network bandwidth is used effectively and such parameters as the network condition and server states have less effect on the system. To resolve this issue, a fuzzy logic controller is used to control the robot’s motion along a predefined path with the necessary manipulation of the normal course. The robot was first modelled in Matlab Simulink and the fuzzy logic rules were optimized for the best results possible. In accordance with the fuzzy rules developed the fuzzy interference system generates the

  12. Elementary Surveillance (ELS) and Enhanced Surveillance (EHS) Validation via Mode S Secondary Radar Surveillance

    National Research Council Canada - National Science Library

    Grappel, Robert D; Harris, Garrett S; Kozar, Mark J; Wiken, Randall T

    2008-01-01

    ...) and Enhanced Surveillance (ERS) data link applications. The intended audience for this report is an engineering staff assigned the task of implementing a monitoring system used to determine ELS and EHS compliance...

  13. SCORPION II persistent surveillance system with universal gateway

    Science.gov (United States)

    Coster, Michael; Chambers, Jonathan; Brunck, Albert

    2009-05-01

    This paper addresses improvements and benefits derived from the next generation Northrop Grumman SCORPION II family of persistent surveillance and target recognition systems produced by the Xetron campus in Cincinnati, Ohio. SCORPION II reduces the size, weight, and cost of all SCORPION components in a flexible, field programmable system that is easier to conceal, backward compatible, and enables integration of over forty Unattended Ground Sensor (UGS) and camera types from a variety of manufacturers, with a modular approach to supporting multiple Line of Sight (LOS) and Beyond Line of Sight (BLOS) communications interfaces. Since 1998 Northrop Grumman has been integrating best in class sensors with its proven universal modular Gateway to provide encrypted data exfiltration to Common Operational Picture (COP) systems and remote sensor command and control. In addition to being fed to COP systems, SCORPION and SCORPION II data can be directly processed using a common sensor status graphical user interface (GUI) that allows for viewing and analysis of images and sensor data from up to seven hundred SCORPION system Gateways on single or multiple displays. This GUI enables a large amount of sensor data and imagery to be used for actionable intelligence as well as remote sensor command and control by a minimum number of analysts.

  14. Parallel Computational Intelligence-Based Multi-Camera Surveillance System

    Directory of Open Access Journals (Sweden)

    Sergio Orts-Escolano

    2014-04-01

    Full Text Available In this work, we present a multi-camera surveillance system based on the use of self-organizing neural networks to represent events on video. The system processes several tasks in parallel using GPUs (graphic processor units. It addresses multiple vision tasks at various levels, such as segmentation, representation or characterization, analysis and monitoring of the movement. These features allow the construction of a robust representation of the environment and interpret the behavior of mobile agents in the scene. It is also necessary to integrate the vision module into a global system that operates in a complex environment by receiving images from multiple acquisition devices at video frequency. Offering relevant information to higher level systems, monitoring and making decisions in real time, it must accomplish a set of requirements, such as: time constraints, high availability, robustness, high processing speed and re-configurability. We have built a system able to represent and analyze the motion in video acquired by a multi-camera network and to process multi-source data in parallel on a multi-GPU architecture.

  15. Experiences with the Twitter Health Surveillance (THS) System.

    Science.gov (United States)

    Rodríguez-Martínez, Manuel

    2017-06-01

    Social media has become an important platform to gauge public opinion on topics related to our daily lives. In practice, processing these posts requires big data analytics tools since the volume of data and the speed of production overwhelm single-server solutions. Building an application to capture and analyze posts from social media can be a challenge simply because it requires combining a set of complex software tools that often times are tricky to configure, tune, and maintain. In many instances, the application ends up being an assorted collection of Java/Scala programs or Python scripts that developers cobble together to generate the data products they need. In this paper, we present the Twitter Health Surveillance (THS) application framework. THS is designed as a platform to allow end-users to monitor a stream of tweets, and process the stream with a combination of built-in functionality and their own user-defined functions. We discuss the architecture of THS, and describe its implementation atop the Apache Hadoop Ecosystem. We also present several lessons learned while developing our current prototype.

  16. Experiences with the Twitter Health Surveillance (THS) System

    Science.gov (United States)

    Rodríguez-Martínez, Manuel

    2018-01-01

    Social media has become an important platform to gauge public opinion on topics related to our daily lives. In practice, processing these posts requires big data analytics tools since the volume of data and the speed of production overwhelm single-server solutions. Building an application to capture and analyze posts from social media can be a challenge simply because it requires combining a set of complex software tools that often times are tricky to configure, tune, and maintain. In many instances, the application ends up being an assorted collection of Java/Scala programs or Python scripts that developers cobble together to generate the data products they need. In this paper, we present the Twitter Health Surveillance (THS) application framework. THS is designed as a platform to allow end-users to monitor a stream of tweets, and process the stream with a combination of built-in functionality and their own user-defined functions. We discuss the architecture of THS, and describe its implementation atop the Apache Hadoop Ecosystem. We also present several lessons learned while developing our current prototype. PMID:29607412

  17. Commercial-off-the-shelf digital surveillance systems for safeguards

    International Nuclear Information System (INIS)

    Neufing, C.; Tschritter, C.; Meylemans, P.; Vandaele, R.; Heppleston, M.; Chare, P.; Kloeckner, W.

    2001-01-01

    The reasons why safeguards authorities are from time to time looking for Commercial-Off-The-Shelf (C.O.T.S.) equipment for safeguards purposes are for the following reasons: Equipment that is designed from scratch to satisfy specific safeguards requirements is very likely to go through a period of teething problems. If these problems are only discovered once the equipment is deployed for routine use, this will be accompanied with large overhead costs for the safeguards authorities to maintain and repair such equipment. The overhead costs are much higher if unattended equipment is concerned that is permanently installed on-site. In that case an extra mission has to be organised to return the faulty equipment to our headquarters before it can be repaired. Using C.O.T.S. equipment that is also used by others reduces the risk of teething problems. At least the burden of going through such kind of problem period is shared with other customers of the concerned equipment. It is clear that safeguards is not a big market on its own. The non-negligible cost of the development of equipment that only fits safeguards requirements will therefore have to be recovered on the expected sales. If the market is small, if the expected number of units that can be sold is small, a large part of the unit cost will depend on the initial development costs. Going for C.O.T.S. equipment that is also sold in other markets, would in that respect lower the equipment cost. That not any safeguards equipment can be obtained commercially off the shelf is clear, but in certain domains like digital surveillance, the functionality of C.O.T.S. equipment has been approaching the one needed for safeguards. That is why in 1998 the Euratom Safeguards Office published an open call for tender for the purchase of a digital surveillance system that is able to support up to 64 colour camera channels. In response to a successful bid for this call for tender a contract for the delivery of 3 prototype systems and 6

  18. Establishment of a High Canine Rabies Burden in Haiti through the Implementation of a Novel Surveillance Program [corrected].

    Directory of Open Access Journals (Sweden)

    Ryan M Wallace

    2015-11-01

    Full Text Available The Republic of Haiti is one of only several countries in the Western Hemisphere in which canine rabies is still endemic. Estimation methods have predicted that 130 human deaths occur per year, yet existing surveillance mechanisms have detected few of these rabies cases. Likewise, canine rabies surveillance capacity has had only limited capacity, detecting only two rabid dogs per year, on average. In 2013, Haiti initiated a community-based animal rabies surveillance program comprised of two components: active community bite investigation and passive animal rabies investigation. From January 2013 -December 2014, 778 rabies suspect animals were reported for investigation. Rabies was laboratory-confirmed in 70 animals (9% and an additional 36 cases were identified based on clinical diagnosis (5%, representing an 18-fold increase in reporting of rabid animals compared to the three years before the program was implemented. Dogs were the most frequent rabid animal (90%. Testing and observation ruled out rabies in 61% of animals investigated. A total of 639 bite victims were reported to the program and an additional 364 bite victims who had not sought medical care were identified during the course of investigations. Only 31% of people with likely rabies exposures had initiated rabies post-exposure prophylaxis prior to the investigation. Rabies is a neglected disease in-part due to a lack of surveillance and understanding about the burden. The surveillance methods employed by this program established a much higher burden of canine rabies in Haiti than previously recognized. The active, community-based bite investigations identified numerous additional rabies exposures and bite victims were referred for appropriate medical care, averting potential human rabies deaths. The use of community-based rabies surveillance programs such as HARSP should be considered in canine rabies endemic countries.

  19. Application of robust face recognition in video surveillance systems

    Science.gov (United States)

    Zhang, De-xin; An, Peng; Zhang, Hao-xiang

    2018-03-01

    In this paper, we propose a video searching system that utilizes face recognition as searching indexing feature. As the applications of video cameras have great increase in recent years, face recognition makes a perfect fit for searching targeted individuals within the vast amount of video data. However, the performance of such searching depends on the quality of face images recorded in the video signals. Since the surveillance video cameras record videos without fixed postures for the object, face occlusion is very common in everyday video. The proposed system builds a model for occluded faces using fuzzy principal component analysis (FPCA), and reconstructs the human faces with the available information. Experimental results show that the system has very high efficiency in processing the real life videos, and it is very robust to various kinds of face occlusions. Hence it can relieve people reviewers from the front of the monitors and greatly enhances the efficiency as well. The proposed system has been installed and applied in various environments and has already demonstrated its power by helping solving real cases.

  20. Success Factors of European Syndromic Surveillance Systems: A Worked Example of Applying Qualitative Comparative Analysis.

    Science.gov (United States)

    Ziemann, Alexandra; Fouillet, Anne; Brand, Helmut; Krafft, Thomas

    2016-01-01

    Syndromic surveillance aims at augmenting traditional public health surveillance with timely information. To gain a head start, it mainly analyses existing data such as from web searches or patient records. Despite the setup of many syndromic surveillance systems, there is still much doubt about the benefit of the approach. There are diverse interactions between performance indicators such as timeliness and various system characteristics. This makes the performance assessment of syndromic surveillance systems a complex endeavour. We assessed if the comparison of several syndromic surveillance systems through Qualitative Comparative Analysis helps to evaluate performance and identify key success factors. We compiled case-based, mixed data on performance and characteristics of 19 syndromic surveillance systems in Europe from scientific and grey literature and from site visits. We identified success factors by applying crisp-set Qualitative Comparative Analysis. We focused on two main areas of syndromic surveillance application: seasonal influenza surveillance and situational awareness during different types of potentially health threatening events. We found that syndromic surveillance systems might detect the onset or peak of seasonal influenza earlier if they analyse non-clinical data sources. Timely situational awareness during different types of events is supported by an automated syndromic surveillance system capable of analysing multiple syndromes. To our surprise, the analysis of multiple data sources was no key success factor for situational awareness. We suggest to consider these key success factors when designing or further developing syndromic surveillance systems. Qualitative Comparative Analysis helped interpreting complex, mixed data on small-N cases and resulted in concrete and practically relevant findings.

  1. Context-based object-of-interest detection for a generic traffic surveillance analysis system

    NARCIS (Netherlands)

    Bao, X.; Javanbakhti, S.; Zinger, S.; Wijnhoven, R.G.J.; With, de P.H.N.

    2014-01-01

    We present a new traffic surveillance video analysis system, focusing on building a framework with robust and generic techniques, based on both scene understanding and moving object-of-interest detection. Since traffic surveillance is widely applied, we want to design a single system that can be

  2. Low-Cost National Media-Based Surveillance System for Public Health Events, Bangladesh

    Science.gov (United States)

    Ao, Trong T.; Rahman, Mahmudur; Haque, Farhana; Chakraborty, Apurba; Hossain, M. Jahangir; Haider, Sabbir; Alamgir, A.S.M.; Sobel, Jeremy; Luby, Stephen P.

    2016-01-01

    We assessed a media-based public health surveillance system in Bangladesh during 2010–2011. The system is a highly effective, low-cost, locally appropriate, and sustainable outbreak detection tool that could be used in other low-income, resource-poor settings to meet the capacity for surveillance outlined in the International Health Regulations 2005. PMID:26981877

  3. 77 FR 52317 - Record of Decision for Surveillance Towed Array Sensor System Low Frequency Active Sonar

    Science.gov (United States)

    2012-08-29

    ... DEPARTMENT OF DEFENSE Department of the Navy Record of Decision for Surveillance Towed Array Sensor System Low Frequency Active Sonar AGENCY: Department of the Navy, DoD. ACTION: Notice of decision... to employ up to four Surveillance Towed Array Sensor System Low Frequency Active (SURTASS LFA) sonar...

  4. Digitized video subject positioning and surveillance system for PET

    International Nuclear Information System (INIS)

    Picard, Y.; Thompson, C.J.

    1995-01-01

    Head motion is a significant contribution to the degradation of image quality of Positron Emission Tomography (PET) studies. Images from different studies must also be realigned digitally to be correlated when the subject position has changed. These constraints could be eliminated if the subject's head position could be monitored accurately. The authors have developed a video camera-based surveillance system to monitor the head position and motion of subjects undergoing PET studies. The system consists of two CCD (charge-coupled device) cameras placed orthogonally such that both face and profile views of the subject's head are displayed side by side on an RGB video monitor. Digitized images overlay the live images in contrasting colors on the monitor. Such a system can be used to (1) position the subject in the field of view (FOV) by displaying the position of the scanner's slices on the monitor along with the current subject position, (2) monitor head motion and alert the operator of any motion during the study and (3) reposition the subject accurately for subsequent studies by displaying the previous position along with the current position in a contrasting color

  5. Traffic flow wide-area surveillance system definition

    Energy Technology Data Exchange (ETDEWEB)

    Allgood, G.O.; Ferrell, R.K.; Kercel, S.W.; Abston, R.A.; Carnal, C.L. [Oak Ridge National Lab., TN (United States); Moynihan, P.I. [Jet Propulsion Lab., Pasadena, CA (United States)

    1994-11-01

    Traffic Flow Wide-Area Surveillance (TFWAS) is a system for assessing the state of traffic flow over a wide area for enhanced traffic control and improved traffic management and planning. The primary purpose of a TFWAS system is to provide a detailed traffic flow description and context description to sophisticated traffic management and control systems being developed or envisioned for the future. A successful TFWAS system must possess the attributes of safety, reconfigurability, reliability, and expandability. The primary safety premise of TFWAS is to ensure that no action or failure of the TFWAS system or its components can result in risk of injury to humans. A wide variety of communication techniques is available for use with TFWAS systems. These communication techniques can be broken down into two categories, landlines and wireless. Currently used and possible future traffic sensing technologies have been examined. Important criteria for selecting TFWAS sensors include sensor capabilities, costs, operational constraints, sensor compatibility with the infrastructure, and extent. TFWAS is a concept that can take advantage of the strengths of different traffic sensing technologies, can readily adapt to newly developed technologies, and can grow with the development of new traffic control strategies. By developing innovative algorithms that will take information from a variety of sensor types and develop descriptions of traffic flows over a wide area, a more comprehensive understanding of the traffic state can be provided to the control system to perform the most reasonable control actions over the entire wide area. The capability of characterizing the state of traffic over an entire region should revolutionize developments in traffic control strategies.

  6. Profile: Agincourt Health and Socio-demographic Surveillance System

    Science.gov (United States)

    Kahn, Kathleen; Collinson, Mark A; Gómez-Olivé, F Xavier; Mokoena, Obed; Twine, Rhian; Mee, Paul; Afolabi, Sulaimon A; Clark, Benjamin D; Kabudula, Chodziwadziwa W; Khosa, Audrey; Khoza, Simon; Shabangu, Mildred G; Silaule, Bernard; Tibane, Jeffrey B; Wagner, Ryan G; Garenne, Michel L; Clark, Samuel J; Tollman, Stephen M

    2012-01-01

    The Agincourt health and socio-demographic surveillance system (HDSS), located in rural northeast South Africa close to the Mozambique border, was established in 1992 to support district health systems development led by the post-apartheid ministry of health. The HDSS (90 000 people), based on an annual update of resident status and vital events, now supports multiple investigations into the causes and consequences of complex health, population and social transitions. Observational work includes cohorts focusing on different stages along the life course, evaluation of national policy at population, household and individual levels and examination of household responses to shocks and stresses and the resulting pathways influencing health and well-being. Trials target children and adolescents, including promoting psycho-social well-being, preventing HIV transmission and reducing metabolic disease risk. Efforts to enhance the research platform include using automated measurement techniques to estimate cause of death by verbal autopsy, full ‘reconciliation’ of in- and out-migrations, follow-up of migrants departing the study area, recording of extra-household social connections and linkage of individual HDSS records with those from sub-district clinics. Fostering effective collaborations (including INDEPTH multi-centre work in adult health and ageing and migration and urbanization), ensuring cross-site compatibility of common variables and optimizing public access to HDSS data are priorities. PMID:22933647

  7. Evolution of Mosquito-Based Arbovirus Surveillance Systems in Australia

    Directory of Open Access Journals (Sweden)

    Andrew F. van den Hurk

    2012-01-01

    Full Text Available Control of arboviral disease is dependent on the sensitive and timely detection of elevated virus activity or the identification of emergent or exotic viruses. The emergence of Japanese encephalitis virus (JEV in northern Australia revealed numerous problems with performing arbovirus surveillance in remote locations. A sentinel pig programme detected JEV activity, although there were a number of financial, logistical, diagnostic and ethical limitations. A system was developed which detected viral RNA in mosquitoes collected by solar or propane powered CO2-baited traps. However, this method was hampered by trap-component malfunction, microbial contamination and large mosquito numbers which overwhelmed diagnostic capabilities. A novel approach involves allowing mosquitoes within a box trap to probe a sugar-baited nucleic-acid preservation card that is processed for expectorated arboviruses. In a longitudinal field trial, both Ross River and Barmah Forest viruses were detected numerous times from multiple traps over different weeks. Further refinements, including the development of unpowered traps and use of yeast-generated CO2, could enhance the applicability of this system to remote locations. New diagnostic technology, such as next generation sequencing and biosensors, will increase the capacity for recognizing emergent or exotic viruses, while cloud computing platforms will facilitate rapid dissemination of data.

  8. A methodological framework for the evaluation of syndromic surveillance systems: a case study of England.

    Science.gov (United States)

    Colón-González, Felipe J; Lake, Iain R; Morbey, Roger A; Elliot, Alex J; Pebody, Richard; Smith, Gillian E

    2018-04-24

    Syndromic surveillance complements traditional public health surveillance by collecting and analysing health indicators in near real time. The rationale of syndromic surveillance is that it may detect health threats faster than traditional surveillance systems permitting more timely, and hence potentially more effective public health action. The effectiveness of syndromic surveillance largely relies on the methods used to detect aberrations. Very few studies have evaluated the performance of syndromic surveillance systems and consequently little is known about the types of events that such systems can and cannot detect. We introduce a framework for the evaluation of syndromic surveillance systems that can be used in any setting based upon the use of simulated scenarios. For a range of scenarios this allows the time and probability of detection to be determined and uncertainty is fully incorporated. In addition, we demonstrate how such a framework can model the benefits of increases in the number of centres reporting syndromic data and also determine the minimum size of outbreaks that can or cannot be detected. Here, we demonstrate its utility using simulations of national influenza outbreaks and localised outbreaks of cryptosporidiosis. Influenza outbreaks are consistently detected with larger outbreaks being detected in a more timely manner. Small cryptosporidiosis outbreaks (framework constitutes a useful tool for public health emergency preparedness in multiple settings. The proposed framework allows the exhaustive evaluation of any syndromic surveillance system and constitutes a useful tool for emergency preparedness and response.

  9. Integrated Disease Investigations and Surveillance planning: a systems approach to strengthening national surveillance and detection of events of public health importance in support of the International Health Regulations

    Directory of Open Access Journals (Sweden)

    Kennedy Sarah

    2010-12-01

    Full Text Available Abstract The international community continues to define common strategic themes of actions to improve global partnership and international collaborations in order to protect our populations. The International Health Regulations (IHR[2005] offer one of these strategic themes whereby World Health Organization (WHO Member States and global partners engaged in biosecurity, biosurveillance and public health can define commonalities and leverage their respective missions and resources to optimize interventions. The U.S. Defense Threat Reduction Agency’s Cooperative Biologica Engagement Program (CBEP works with partner countries across clinical, veterinary, epidemiological, and laboratory communities to enhance national disease surveillance, detection, diagnostic, and reporting capabilities. CBEP, like many other capacity building programs, has wrestled with ways to improve partner country buy-in and ownership and to develop sustainable solutions that impact integrated disease surveillance outcomes. Designing successful implementation strategies represents a complex and challenging exercise and requires robust and transparent collaboration at the country level. To address this challenge, the Laboratory Systems Development Branch of the U.S. Centers for Disease Control and Prevention (CDC and CBEP have partnered to create a set of tools that brings together key leadership of the surveillance system into a deliberate system design process. This process takes into account strengths and limitations of the existing system, how the components inter-connect and relate to one another, and how they can be systematically refined within the local context. The planning tools encourage cross-disciplinary thinking, critical evaluation and analysis of existing capabilities, and discussions across organizational and departmental lines toward a shared course of action and purpose. The underlying concepts and methodology of these tools are presented here.

  10. Implementing a public web based GIS service for feedback of surveillance data on communicable diseases in Sweden

    Directory of Open Access Journals (Sweden)

    Ekdahl Karl

    2004-06-01

    Full Text Available Abstract Background Surveillance data allow for analysis, providing public health officials and policy-makers with a basis for long-term priorities and timely information on possible outbreaks for rapid response (data for action. In this article we describe the considerations and technology behind a newly introduced public web tool in Sweden for easy retrieval of county and national surveillance data on communicable diseases. Methods The web service was designed to automatically present updated surveillance statistics of some 50 statutory notifiable diseases notified to the Swedish Institute for Infectious Disease Control (SMI. The surveillance data is based on clinical notifications from the physician having treated the patient and laboratory notifications, merged into cases using a unique personal identification number issued to all Swedish residents. The web service use notification data from 1997 onwards, stored in a relational database at the SMI. Results The web service presents surveillance data to the user in various ways; tabulated data containing yearly and monthly disease data per county, age and sex distribution, interactive maps illustrating the total number of cases and the incidence per county and time period, graphs showing the total number of cases per week and graphs illustrating trends in the disease data. The system design encompasses the database (storing the data, the web server (holding the web service and an in-the-middle computer (to ensure good security standards. Conclusions The web service has provided the health community, the media, and the public with easy access to both timely and detailed surveillance data presented in various forms. Since it was introduced in May 2003, the system has been accessed more than 1,000,000 times, by more than 10,000 different viewers (over 12.600 unique IP-numbers.

  11. 77 FR 52742 - Public Meeting-Strengthening the National Medical Device Postmarket Surveillance System; Request...

    Science.gov (United States)

    2012-08-30

    ... Contact Person) no later than September 5, 2012. No commercial or promotional material will be permitted... develop and implement a comprehensive medical device postmarket surveillance strategy to collect, analyze... implementing this strategy, FDA is holding a public meeting to discuss the current and future state of medical...

  12. Surveillance system using the CCTV at the fuel transfer pond in the Tokai reprocessing plant

    International Nuclear Information System (INIS)

    Hayakawa, T.; Fukuhara, J.; Ochiai, K.; Ohnishi, T.; Ogata, Y.; Okamoto, H.

    1991-01-01

    The Fuel Transfer Pond (FTP) in the Tokai Reprocessing Plant (TRP) is a strategic point for safeguards. Spent fuels, therefore, in the FTP have been surveyed by the surveillance system using the underwater CCTV. This system was developed through the improvement of devices composed of cameras and VCRs and the provision of tamper resistance function as one of the JASPAS (Japan Support Program for Agency Safeguards) program. The purpose of this program is to realize the continuous surveillance of the slanted tunnel through which the spent fuel on the conveyor is moved from the FTP to the Mechanical Processing Cell (MPC). This paper reports that, when this surveillance system is applied to an inspection device, the following requirements are needed: To have the ability of continuous and unattended surveillance of the spent fuel on the conveyor path from the FTP to the MPC; To have the tamper resistance function for continuous and unattended surveillance of the spent fuel

  13. Using Surveillance Camera Systems to Monitor Public Domains: Can Abuse Be Prevented

    Science.gov (United States)

    2006-03-01

    relationship with a 16-year old girl failed. The incident was captured by a New York City Police Department surveillance camera. Although the image...administrators stated that the images recorded were “…nothing more than images of a few bras and panties .”17 The use of CCTV surveillance systems for

  14. Designing a Low-Resolution Face Recognition System for Long-Range Surveillance

    NARCIS (Netherlands)

    Peng, Y.; Spreeuwers, Lieuwe Jan; Veldhuis, Raymond N.J.

    2016-01-01

    Most face recognition systems deal well with high-resolution facial images, but perform much worse on low-resolution facial images. In low-resolution face recognition, there is a specific but realistic surveillance scenario: a surveillance camera monitoring a large area. In this scenario, usually

  15. Functions and Requirements and Specifications for Replacement of the Computer Automated Surveillance System (CASS)

    International Nuclear Information System (INIS)

    SCAIEF, C.C.

    1999-01-01

    This functions, requirements and specifications document defines the baseline requirements and criteria for the design, purchase, fabrication, construction, installation, and operation of the system to replace the Computer Automated Surveillance System (CASS) alarm monitoring

  16. Using a data fusion-based activity recognition framework to determine surveillance system requirements

    CSIR Research Space (South Africa)

    Le Roux, WH

    2007-07-01

    Full Text Available A technique is proposed to extract system requirements for a maritime area surveillance system, based on an activity recognition framework originally intended for the characterisation, prediction and recognition of intentional actions for threat...

  17. Implementation of Molecular Surveillance After a Cluster of Fatal Toxoplasmosis at 2 Neighboring Transplant Centers.

    Science.gov (United States)

    Isa, Flonza; Saito, Kohta; Huang, Yao-Ting; Schuetz, Audrey; Babady, N Esther; Salvatore, Steven; Pessin, Melissa; van Besien, Koen; Perales, Miguel-Angel; Giralt, Sergio; Sepkowitz, Kent; Papanicolaou, Genovefa A; Soave, Rosemary; Kamboj, Mini

    2016-08-15

    After a cluster of fatal toxoplasmosis among stem cell transplant recipients at 2 hospitals, surveillance with polymerase chain reaction (PCR) (blood) was instituted. Rate of reactivation among seropositive recipients was 2.2 and 16%. Parasitemia was successfully managed with preemptive treatment. For seropositive recipients unable to take prophylaxis, toxoplasma PCR surveillance should be routinely performed. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  18. Candid camera : video surveillance system can help protect assets

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, L.

    2009-11-15

    By combining closed-circuit cameras with sophisticated video analytics to create video sensors for use in remote areas, Calgary-based IntelliView Technologies Inc.'s explosion-proof video surveillance system can help the oil and gas sector monitor its assets. This article discussed the benefits, features, and applications of IntelliView's technology. Some of the benefits include a reduced need for on-site security and operating personnel and its patented analytics product known as the SmrtDVR, where the camera's images are stored. The technology can be used in temperatures as cold as minus 50 degrees Celsius and as high as 50 degrees Celsius. The product was commercialized in 2006 when it was used by Nexen Inc. It was concluded that false alarms set off by natural occurrences such as rain, snow, glare and shadows were a huge problem with analytics in the past, but that problem has been solved by IntelliView, which has its own source code, and re-programmed code. 1 fig.

  19. Rotating machinery surveillance system reduces plant downtime and radiation exposure

    International Nuclear Information System (INIS)

    Bohanick, J.S.; Robinson, J.C.; Allen, J.W.

    1988-01-01

    A rotating machinery surveillance system (RMSS) was permanently installed at Grand Gulf nuclear station (GGNS) as part of a program sponsored by the US Department of Energy whose goal was to reduce radiation exposure to power plant personnel resulting from the inspection, maintenance, and repair of rotating machinery. The RMSS was installed at GGNS in 1983 to continuously monitor 173 analog vibration signals from proximity probes mounted on 26 machine trains and ∼450 process data points via a computer data link. Vibration frequency spectra, i.e., the vibration amplitude versus frequency of vibration, and various characterizations of these spectra are the fundamental data collected by the RMSS for performing machinery diagnostics. The RMSS collects vibration frequency spectra on a daily basis for all the monitored rotating equipment and automatically stores the collected spectra for review by the vibration engineer. Vibration spectra automatically stored by the RMSS fall into categories that include the last normal, alarm, minimum and maximum, past three-day data set, baseline, current, and user-saved spectra. During first and second fuel-cycle operation at GGNS, several significant vibration problems were detected by the RMSS. Two of these are presented in this paper: recirculation pumps and turbine-generator bearing degradation. The total reduction in personnel radiation exposure at GGNS from 1985 to 1987 due to the presence of the RMSS was estimated to be in the range from 49 to 54 person-rem

  20. Taking care of hospital physicians: Development and implementation of a job-specific workers’ health surveillance

    NARCIS (Netherlands)

    Ruitenburg, M.M.

    2016-01-01

    A Workers’ Health Surveillance (WHS) can serve as an occupational health strategy to maintain or promote work-related health and work functioning of employees. The aims of this thesis were to assess the evidence-based content of a job-specific WHS for hospital physicians (medical specialists and

  1. Using cloud computing technologies in IP-video surveillance systems with the function of 3d-object modelling

    Directory of Open Access Journals (Sweden)

    Zhigalov Kirill

    2018-01-01

    Full Text Available This article is devoted to the integration of cloud technology functions into 3D IP video surveil-lance systems in order to conduct further video Analytics, incoming real-time data, as well as stored video materials on the server in the «cloud». The main attention is devoted to «cloud technologies» usage optimizing the process of recognition of the desired object by increasing the criteria of flexibility and scalability of the system. Transferring image load from the client to the cloud server, to the virtual part of the system. The development of the issues considered in the article in terms of data analysis, which will significantly improve the effectiveness of the implementation of special tasks facing special units.

  2. A video imaging system and related control hardware for nuclear safeguards surveillance applications

    International Nuclear Information System (INIS)

    Whichello, J.V.

    1987-03-01

    A novel video surveillance system has been developed for safeguards applications in nuclear installations. The hardware was tested at a small experimental enrichment facility located at the Lucas Heights Research Laboratories. The system uses digital video techniques to store, encode and transmit still television pictures over the public telephone network to a receiver located in the Australian Safeguards Office at Kings Cross, Sydney. A decoded, reconstructed picture is then obtained using a second video frame store. A computer-controlled video cassette recorder is used automatically to archive the surveillance pictures. The design of the surveillance system is described with examples of its operation

  3. A scenario tree model for the Canadian Notifiable Avian Influenza Surveillance System and its application to estimation of probability of freedom and sample size determination.

    Science.gov (United States)

    Christensen, Jette; Stryhn, Henrik; Vallières, André; El Allaki, Farouk

    2011-05-01

    In 2008, Canada designed and implemented the Canadian Notifiable Avian Influenza Surveillance System (CanNAISS) with six surveillance activities in a phased-in approach. CanNAISS was a surveillance system because it had more than one surveillance activity or component in 2008: passive surveillance; pre-slaughter surveillance; and voluntary enhanced notifiable avian influenza surveillance. Our objectives were to give a short overview of two active surveillance components in CanNAISS; describe the CanNAISS scenario tree model and its application to estimation of probability of populations being free of NAI virus infection and sample size determination. Our data from the pre-slaughter surveillance component included diagnostic test results from 6296 serum samples representing 601 commercial chicken and turkey farms collected from 25 August 2008 to 29 January 2009. In addition, we included data from a sub-population of farms with high biosecurity standards: 36,164 samples from 55 farms sampled repeatedly over the 24 months study period from January 2007 to December 2008. All submissions were negative for Notifiable Avian Influenza (NAI) virus infection. We developed the CanNAISS scenario tree model, so that it will estimate the surveillance component sensitivity and the probability of a population being free of NAI at the 0.01 farm-level and 0.3 within-farm-level prevalences. We propose that a general model, such as the CanNAISS scenario tree model, may have a broader application than more detailed models that require disease specific input parameters, such as relative risk estimates. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  4. Multi-modal low cost mobile indoor surveillance system on the Robust Artificial Intelligence-based Defense Electro Robot (RAIDER)

    Science.gov (United States)

    Nair, Binu M.; Diskin, Yakov; Asari, Vijayan K.

    2012-10-01

    We present an autonomous system capable of performing security check routines. The surveillance machine, the Clearpath Husky robotic platform, is equipped with three IP cameras with different orientations for the surveillance tasks of face recognition, human activity recognition, autonomous navigation and 3D reconstruction of its environment. Combining the computer vision algorithms onto a robotic machine has given birth to the Robust Artificial Intelligencebased Defense Electro-Robot (RAIDER). The end purpose of the RAIDER is to conduct a patrolling routine on a single floor of a building several times a day. As the RAIDER travels down the corridors off-line algorithms use two of the RAIDER's side mounted cameras to perform a 3D reconstruction from monocular vision technique that updates a 3D model to the most current state of the indoor environment. Using frames from the front mounted camera, positioned at the human eye level, the system performs face recognition with real time training of unknown subjects. Human activity recognition algorithm will also be implemented in which each detected person is assigned to a set of action classes picked to classify ordinary and harmful student activities in a hallway setting.The system is designed to detect changes and irregularities within an environment as well as familiarize with regular faces and actions to distinguish potentially dangerous behavior. In this paper, we present the various algorithms and their modifications which when implemented on the RAIDER serves the purpose of indoor surveillance.

  5. Stakeholder perspectives on dissemination and implementation of a prospective surveillance model of rehabilitation for breast cancer treatment.

    Science.gov (United States)

    Stout, Nicole L; Andrews, Kimberly; Binkley, Jill M; Schmitz, Kathryn H; Smith, Robert A

    2012-04-15

    The prospective surveillance model proposes a paradigm shift in the delivery of care for patients with breast cancer. The model is based on clinical research and clinical practice experience that was reviewed and discussed at a multidisciplinary meeting. The model identifies critical physical sequelae of treatment as well as timeframes for identification of and surveillance for these issues. Although the model of ongoing assessment for physical impairment and early rehabilitative intervention creates a framework for care, broad support and active dissemination among a variety of stakeholders will be required to transform patient care. Translating research findings to transform practice often occurs on a protracted timeline. The authors sought participation from a variety of stakeholder representatives throughout the process of creating this model in an effort to ensure that it reflects the realities of the patient experience and care delivery, to incorporate their input regarding the construct and viability of the model, and to potentiate effective and efficient strategies for implementation. This article summarizes comments from stakeholder representatives concerning the prospective surveillance model for rehabilitation for women treated for breast cancer. Concerns addressed include the scope of impairments included in the model, the potential creation of barriers to exercise and participation in community exercise programs, and cost and feasibility issues. Stakeholder disseminations strategies are also presented. Overall, there is recognition by the stakeholder group that this model calls attention to important unmet needs and defines a crucial opportunity to improve care for breast cancer survivors. Copyright © 2012 American Cancer Society.

  6. The Added-Value of Using Participatory Approaches to Assess the Acceptability of Surveillance Systems: The Case of Bovine Tuberculosis in Belgium

    Science.gov (United States)

    Calba, Clémentine; Goutard, Flavie Luce; Vanholme, Luc; Antoine-Moussiaux, Nicolas; Hendrikx, Pascal; Saegerman, Claude

    2016-01-01

    Context and Objective Bovine tuberculosis (bTB) surveillance in Belgium is essential to maintain the officially free status and to preserve animal and public health. An evaluation of the system is thus needed to ascertain the surveillance provides a precise description of the current situation in the country. The evaluation should assess stakeholders’ perceptions and expectations about the system due to the fact that the acceptability has an influence on the levels of sensitivity and timeliness of the surveillance system. The objective of the study was to assess the acceptability of the bTB surveillance in Belgium, using participatory tools and the OASIS flash tool (‘analysis tool for surveillance systems’). Methods For the participatory process, focus group discussions and individual interviews were implemented with representatives involved with the system, both from cattle and wildlife part of the surveillance. Three main tools were used: (i) relational diagrams associated with smileys, (ii) flow diagrams associated with proportional piling, and (iii) impact diagrams associated with proportional piling. A total of six criteria were assessed, among which five were scored on a scale from -1 to +1. For the OASIS flash tool, one full day meeting with representatives from stakeholders involved with the surveillance was organised. A total of 19 criteria linked to acceptability were scored on a scale from 0 to 3. Results and Conclusion Both methods highlighted a medium acceptability of the bTB surveillance. The main elements having a negative influence were the consequences of official notification of a bTB suspect case in a farm, the low remuneration paid to private veterinarians for execution of intradermal tuberculin tests and the practical difficulties about the containment of the animals. Based on the two evaluation processes, relevant recommendations to improve the surveillance were made. Based on the comparison between the two evaluation processes, the

  7. The Canadian Transfusion Surveillance System: what is it and how can the data be used?

    Science.gov (United States)

    Ditomasso, Julie; Liu, Yang; Heddle, Nancy M

    2012-06-01

    Hemovigilance systems are important programs for: monitoring trends of known risks; evaluating effectiveness of steps taken to reduce risks; providing data to support recommendations for change and guideline development; and contributing overall to the safety of transfusion. The Transfusion Transmitted Injury Surveillance System is the hemovigilance system implemented in Canada. It evolved in 1999 as a pilot program and expanded across Canada in 2005. Each province reports their adverse reactions to the transfusion of blood products and plasma proteins to the Public Health Agency of Canada (PHAC) at predetermined intervals. PHAC reconciles, summarizes the data and publishes a report approximately 2 years after the data are collected. This is considered a passive reporting system but in spite of the delays, the program provides useful information to address a variety of questions. Examples include: assessing the impact of a provincial patient transfusion history registry in Québec on reporting of hemolytic transfusion reactions; identifying trends of bacterial contamination of blood products and assessing the impact of interventions on these events; and the impact of male-only plasma on the incidence of Transfusion Related Acute Lung Injury. Although hemovigilance data has been successfully used to improve blood safety, we must continue to explore ways to utilize such data to improve and implement safe transfusion practices. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Surveillance and Measurement System (SAMS). Innovative Technology Summary Report

    International Nuclear Information System (INIS)

    2001-01-01

    The United States Department of Energy (DOE) continually seeks safer and more cost-effective technologies for the decontamination and decommissioning (D and D) of nuclear facilities. The Deactivation and Decommissioning Focus Area (DDFA) of the DOE's Office of Science and Technology sponsors large-scale demonstration and deployment projects (LSDDPs) to identify and demonstrate technologies that will be safer and more cost-effective. At these LSDDPs, developers and vendors of improved or innovative technologies showcase products that are potentially beneficial to the DOE's projects as well as others in the D and D community. Benefits sought include decreased health and safety risks to personnel and the environment, increased productivity, and decreased cost of operation. The Idaho National Engineering and Environmental Laboratory (INEEL) LSDDP generated a list of need statements defining specific needs or problems where improved technologies could be incorporated into ongoing D and D tasks. Advances in characterization technologies are continuously being sought to decrease the cost of sampling and increase the speed of obtaining results. Currently it can take as long as 90 days to receive isotopic analysis of radioactive samples from laboratories on soil, liquid, and paint samples. The cost to analyze these types of samples for radionuclides is about $150 per sample. This demonstration investigated the feasibility of using the Surveillance and Measurement System (SAMS) (innovative technology) to make in situ isotopic radiation measurements in paint and soil. Sample collection and on-site laboratory analysis (baseline technology) is currently being used on D and D sampling activities. Benefits expected from using the innovative technology include: Significant decrease in time to receive results on radiological samples; Decrease in cost associated with sample collection, preparation, analysis, and disposal; Equivalent data quality to laboratory analysis; and Fewer

  9. Implementation Guidelines for BMDO Open Systems Approach

    National Research Council Canada - National Science Library

    1998-01-01

    This Directive: (1) Implements the policy set forth in references (a), (b) and (c); (2) Assigns responsibilities and prescribes mandatory procedures to open systems implementation with EMDO and Service Ballistic Missile Defense...

  10. Guidance for implementing the long-term surveillance program for UMTRA Project Title I Disposal Sites

    International Nuclear Information System (INIS)

    1996-02-01

    This guidance document has two purposes: it provides guidance for writing site-specific long-term surveillance plans (LTSP) and it describes site surveillance, monitoring, and long-term care techniques for Title I disposal sites of the Uranium Mill Tailings Radiation Control Act (UMTRCA) (42 USC Section 7901 et seq.). Long-term care includes monitoring, maintenance, and emergency measures needed to protect public health and safety and the environment after remedial action is completed. This document applies to the UMTRCA-designated Title I disposal sites. The requirements for long-term care of the Title I sites and the contents of the LTSPs are provided in U.S. Nuclear Regulatory Commission (NRC) regulations (10 CFR Section 40.27) provided in Attachment 1

  11. Surveillance and Datalink Communication Performance Analysis for Distributed Separation Assurance System Architectures

    Science.gov (United States)

    Chung, William W.; Linse, Dennis J.; Alaverdi, Omeed; Ifarraguerri, Carlos; Seifert, Scott C.; Salvano, Dan; Calender, Dale

    2012-01-01

    This study investigates the effects of two technical enablers: Automatic Dependent Surveillance - Broadcast (ADS-B) and digital datalink communication, of the Federal Aviation Administration s Next Generation Air Transportation System (NextGen) under two separation assurance (SA) system architectures: ground-based SA and airborne SA, on overall separation assurance performance. Datalink performance such as successful reception probability in both surveillance and communication messages, and surveillance accuracy are examined in various operational conditions. Required SA performance is evaluated as a function of subsystem performance, using availability, continuity, and integrity metrics to establish overall required separation assurance performance, under normal and off-nominal conditions.

  12. Monitoring of health and demographic outcomes in poor urban settlements: evidence from the Nairobi Urban Health and Demographic Surveillance System.

    Science.gov (United States)

    Emina, Jacques; Beguy, Donatien; Zulu, Eliya M; Ezeh, Alex C; Muindi, Kanyiva; Elung'ata, Patricia; Otsola, John K; Yé, Yazoumé

    2011-06-01

    The Nairobi Urban Health and Demographic Surveillance System (NUHDSS) was set up in Korogocho and Viwandani slum settlements to provide a platform for investigating linkages between urban poverty, health, and demographic and other socioeconomic outcomes, and to facilitate the evaluation of interventions to improve the wellbeing of the urban poor. Data from the NUHDSS confirm the high level of population mobility in slum settlements, and also demonstrate that slum settlements are long-term homes for many people. Research and intervention programs should take account of the duality of slum residency. Consistent with the trends observed countrywide, the data show substantial improvements in measures of child mortality, while there has been limited decline in fertility in slum settlements. The NUHDSS experience has shown that it is feasible to set up and implement long-term health and demographic surveillance system in urban slum settlements and to generate vital data for guiding policy and actions aimed at improving the wellbeing of the urban poor.

  13. Internet security information system implement method

    International Nuclear Information System (INIS)

    Liu Baoxu; Mei Jie; Xu Rongsheng; An Dehai; Yu Mingjian; Chen Xiangyang; Zheng Peng

    1999-01-01

    On the basis of analysis of the key elements that will affect the Internet Security Information System, the author takes UNIX Operating System as an example, and provides the important stages that must be considered when implementing the Internet Security Information System. An implemental model of the Internet Security Information System is given

  14. Behavioral Risk Factor Surveillance System (BRFSS) Age-Adjusted Prevalence Data (2011 to present)

    Data.gov (United States)

    U.S. Department of Health & Human Services — 2011 to present. BRFSS combined land line and cell phone age-adjusted prevalence data. The BRFSS is a continuous, state-based surveillance system that collects...

  15. Work-Related Lung Disease Surveillance System (eWoRLD)

    Data.gov (United States)

    U.S. Department of Health & Human Services — A surveillance system that provides morbidity, mortality, and workplace exposure data on work-related respiratory diseases by geographic region, industry and...

  16. Behavioral Risk Factor Surveillance System (BRFSS) Prevalence Data (2011 to present)

    Data.gov (United States)

    U.S. Department of Health & Human Services — 2011 to present. BRFSS combined land line and cell phone prevalence data. BRFSS is a continuous, state-based surveillance system that collects information about...

  17. Behavioral Risk Factor Surveillance System (BRFSS) Prevalence Data (2010 and prior)

    Data.gov (United States)

    U.S. Department of Health & Human Services — 1995-2010. BRFSS land line only prevalence data. BRFSS is a continuous, state-based surveillance system that collects information about modifiable risk factors for...

  18. DASH - Youth Risk Behavior Surveillance System (YRBSS): High School - Excluding Sexual Identity

    Data.gov (United States)

    U.S. Department of Health & Human Services — 1991-2015. High School Dataset. The Youth Risk Behavior Surveillance System (YRBSS) monitors six categories of priority health behaviors among youth and young...

  19. Applied learning-based color tone mapping for face recognition in video surveillance system

    Science.gov (United States)

    Yew, Chuu Tian; Suandi, Shahrel Azmin

    2012-04-01

    In this paper, we present an applied learning-based color tone mapping technique for video surveillance system. This technique can be applied onto both color and grayscale surveillance images. The basic idea is to learn the color or intensity statistics from a training dataset of photorealistic images of the candidates appeared in the surveillance images, and remap the color or intensity of the input image so that the color or intensity statistics match those in the training dataset. It is well known that the difference in commercial surveillance cameras models, and signal processing chipsets used by different manufacturers will cause the color and intensity of the images to differ from one another, thus creating additional challenges for face recognition in video surveillance system. Using Multi-Class Support Vector Machines as the classifier on a publicly available video surveillance camera database, namely SCface database, this approach is validated and compared to the results of using holistic approach on grayscale images. The results show that this technique is suitable to improve the color or intensity quality of video surveillance system for face recognition.

  20. Evaluation of an Electronic Smart-Card Based School Absenteeism Surveillance System

    OpenAIRE

    So, HC; Lam, CK; Tam, YH; Cowling, BJ; Leung, GM; Lau, EHY; Ip, DKM

    2014-01-01

    We evaluated the performance of an electronic smart-card based school absenteeism surveillance system which was initiated in 2008 in Hong Kong. The result demonstrated the feasibility and potential benefit of employing electronic school absenteeism data as captured automatically by a smart card system as an alternative data stream for monitoring influenza activities, and flexibility in establishing surveillance for emerging diseases. The increasing popularity of usage of smart card technology...

  1. Infectious Disease Surveillance in the Big Data Era: Towards Faster and Locally Relevant Systems

    Science.gov (United States)

    Simonsen, Lone; Gog, Julia R.; Olson, Don; Viboud, Cécile

    2016-01-01

    While big data have proven immensely useful in fields such as marketing and earth sciences, public health is still relying on more traditional surveillance systems and awaiting the fruits of a big data revolution. A new generation of big data surveillance systems is needed to achieve rapid, flexible, and local tracking of infectious diseases, especially for emerging pathogens. In this opinion piece, we reflect on the long and distinguished history of disease surveillance and discuss recent developments related to use of big data. We start with a brief review of traditional systems relying on clinical and laboratory reports. We then examine how large-volume medical claims data can, with great spatiotemporal resolution, help elucidate local disease patterns. Finally, we review efforts to develop surveillance systems based on digital and social data streams, including the recent rise and fall of Google Flu Trends. We conclude by advocating for increased use of hybrid systems combining information from traditional surveillance and big data sources, which seems the most promising option moving forward. Throughout the article, we use influenza as an exemplar of an emerging and reemerging infection which has traditionally been considered a model system for surveillance and modeling. PMID:28830112

  2. Infectious Disease Surveillance in the Big Data Era: Towards Faster and Locally Relevant Systems.

    Science.gov (United States)

    Simonsen, Lone; Gog, Julia R; Olson, Don; Viboud, Cécile

    2016-12-01

    While big data have proven immensely useful in fields such as marketing and earth sciences, public health is still relying on more traditional surveillance systems and awaiting the fruits of a big data revolution. A new generation of big data surveillance systems is needed to achieve rapid, flexible, and local tracking of infectious diseases, especially for emerging pathogens. In this opinion piece, we reflect on the long and distinguished history of disease surveillance and discuss recent developments related to use of big data. We start with a brief review of traditional systems relying on clinical and laboratory reports. We then examine how large-volume medical claims data can, with great spatiotemporal resolution, help elucidate local disease patterns. Finally, we review efforts to develop surveillance systems based on digital and social data streams, including the recent rise and fall of Google Flu Trends. We conclude by advocating for increased use of hybrid systems combining information from traditional surveillance and big data sources, which seems the most promising option moving forward. Throughout the article, we use influenza as an exemplar of an emerging and reemerging infection which has traditionally been considered a model system for surveillance and modeling. Published by Oxford University Press for the Infectious Diseases Society of America 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  3. The Establishment and Function of Schistosomiasis Surveillance System Towards Elimination in The People's Republic of China.

    Science.gov (United States)

    Zhang, L-J; Li, S-Z; Wen, L-Y; Lin, D-D; Abe, E M; Zhu, R; Du, Y; Lv, S; Xu, J; Webster, B L; Rollinson, D; Zhou, X-N

    2016-01-01

    Schistosoma japonicum is the main schistosome species in The People's Republic of China, causing intestinal schistosomiasis, a debilitating disease of public health importance. The People's Republic of China used to be heavily endemic with schistosomiasis, but great progress has been made through the vigorous efforts of the national control programmes in the last six decades. Presently, efforts are geared towards eliminating schistosomiasis from The People's Republic of China by the end of 2025 through effective schistosomiasis surveillance, an important component in the drive towards schistosomiasis elimination. Therefore, this article explicitly outlines the development and progress made in schistosomiasis surveillance since 1990 with a special focus on the new surveillance system in use. Although the surveillance system has steadily improved over the years, it is faced with many challenges. Hence, more efforts are needed to establish an effective and sensitive evaluation system for the national schistosomiasis elimination programme in The People's Republic of China. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Light Water Reactor-Pressure Vessel Surveillance project computer system

    International Nuclear Information System (INIS)

    Merriman, S.H.

    1980-10-01

    A dedicated process control computer has been implemented for regulating the metallurgical Pressure Vessel Wall Benchmark Facility (PSF) at the Oak Ridge Research Reactor. The purpose of the PSF is to provide reliable standards and methods by which to judge the radiation damage to reactor pressure vessel specimens. Benchmark data gathered from the PSF will be used to improve and standardize procedures for assessing the remaining safe operating lifetime of aging reactors. The computer system controls the pressure vessel specimen environment in the presence of gamma heating so that in-vessel conditions are simulated. Instrumented irradiation capsules, in which the specimens are housed, contain temperature sensors and electrical heaters. The computer system regulates the amount of power delivered to the electrical heaters based on the temperature distribution within the capsules. Time-temperature profiles are recorded along with reactor conditions for later correlation with specimen metallurgical changes

  5. Guidance for implementing the UMTRA Project long-term surveillance program

    International Nuclear Information System (INIS)

    1992-09-01

    The US Nuclear Regulatory Commission (NRC) has issued a general license for the custody and long-term care of US Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) Project permanent disposal sites. The purpose of this general license is to ensure that the UMTRA disposal sites will be cared for in such a manner as to protect the public health and safety and the environment upon completion of remedial actions. The general license will be in effect for a disposal site when NRC accepts the disposal site long-term surveillance plan (LTSP) that meets the requirements of 10 CFR 40.27. The site LTSP describes in detail the long-term surveillance program, including any monitoring, maintenance, and emergency measures necessary to fulfill the conditions of the general license. This guidance document provides (1) instructions for preparing the disposal site LTSPs and (2) instructions for carrying out the UMTRA Project long-term surveillance program, including any monitoring that may be required. The information provided in this document also is in accordance with the regulatory requirements set forth in 40 CFR 192. On January 5, 1985, the US Tenth Circuit Court of Appeals remanded the groundwater standards, 40 CFR 192.02. Proposed groundwater standards were issued for comment on September 24, 1987 (52 FR 3600). When the groundwater standards become final, this document will be revised, as appropriate. This document also will be updated in response to any changes to 10 CFR 40, or in response to changes in the manner in which the long-term care of the licensed disposal sites is carried out

  6. Evolution of computer-based surveillance, control and man-machine communication systems in nuclear power stations

    International Nuclear Information System (INIS)

    Wilkinson, H.M.

    1980-01-01

    Reactor surveillance systems, man-machine communication, control methods and system relibility have steadily improved with successive designs. These improvements have been dramatic. Operational results from nine power-reactor units and preliminary results from 12 more units in various phases of implementation are now becoming available. The scope of the improvements ranges from the first design which used only lantern type displays to the latest which uses 18 colour cathode ray tubes (CRT). The operator can bnow scan a parallel presentation of annunciator messages, bar charts and graphical presentations. (orig./HP)

  7. Measuring costs of data collection at village clinics by village doctors for a syndromic surveillance system-a cross sectional survey from China.

    Science.gov (United States)

    Ding, Yan; Fei, Yang; Xu, Biao; Yang, Jun; Yan, Weirong; Diwan, Vinod K; Sauerborn, Rainer; Dong, Hengjin

    2015-07-25

    Studies into the costs of syndromic surveillance systems are rare, especially for estimating the direct costs involved in implementing and maintaining these systems. An Integrated Surveillance System in rural China (ISSC project), with the aim of providing an early warning system for outbreaks, was implemented; village clinics were the main surveillance units. Village doctors expressed their willingness to join in the surveillance if a proper subsidy was provided. This study aims to measure the costs of data collection by village clinics to provide a reference regarding the subsidy level required for village clinics to participate in data collection. We conducted a cross-sectional survey with a village clinic questionnaire and a staff questionnaire using a purposive sampling strategy. We tracked reported events using the ISSC internal database. Cost data included staff time, and the annual depreciation and opportunity costs of computers. We measured the village doctors' time costs for data collection by multiplying the number of full time employment equivalents devoted to the surveillance by the village doctors' annual salaries and benefits, which equaled their net incomes. We estimated the depreciation and opportunity costs of computers by calculating the equivalent annual computer cost and then allocating this to the surveillance based on the percentage usage. The estimated total annual cost of collecting data was 1,423 Chinese Renminbi (RMB) in 2012 (P25 = 857, P75 = 3284), including 1,250 RMB (P25 = 656, P75 = 3000) staff time costs and 134 RMB (P25 = 101, P75 = 335) depreciation and opportunity costs of computers. The total costs of collecting data from the village clinics for the syndromic surveillance system was calculated to be low compared with the individual net income in County A.

  8. Kalman Filter Based Tracking in an Video Surveillance System

    Directory of Open Access Journals (Sweden)

    SULIMAN, C.

    2010-05-01

    Full Text Available In this paper we have developed a Matlab/Simulink based model for monitoring a contact in a video surveillance sequence. For the segmentation process and corect identification of a contact in a surveillance video, we have used the Horn-Schunk optical flow algorithm. The position and the behavior of the correctly detected contact were monitored with the help of the traditional Kalman filter. After that we have compared the results obtained from the optical flow method with the ones obtained from the Kalman filter, and we show the correct functionality of the Kalman filter based tracking. The tests were performed using video data taken with the help of a fix camera. The tested algorithm has shown promising results.

  9. Development of the Diabetes Technology Society Blood Glucose Monitor System Surveillance Protocol.

    Science.gov (United States)

    Klonoff, David C; Lias, Courtney; Beck, Stayce; Parkes, Joan Lee; Kovatchev, Boris; Vigersky, Robert A; Arreaza-Rubin, Guillermo; Burk, Robert D; Kowalski, Aaron; Little, Randie; Nichols, James; Petersen, Matt; Rawlings, Kelly; Sacks, David B; Sampson, Eric; Scott, Steve; Seley, Jane Jeffrie; Slingerland, Robbert; Vesper, Hubert W

    2016-05-01

    Inaccurate blood glucsoe monitoring systems (BGMSs) can lead to adverse health effects. The Diabetes Technology Society (DTS) Surveillance Program for cleared BGMSs is intended to protect people with diabetes from inaccurate, unreliable BGMS products that are currently on the market in the United States. The Surveillance Program will provide an independent assessment of the analytical performance of cleared BGMSs. The DTS BGMS Surveillance Program Steering Committee included experts in glucose monitoring, surveillance testing, and regulatory science. Over one year, the committee engaged in meetings and teleconferences aiming to describe how to conduct BGMS surveillance studies in a scientifically sound manner that is in compliance with good clinical practice and all relevant regulations. A clinical surveillance protocol was created that contains performance targets and analytical accuracy-testing studies with marketed BGMS products conducted by qualified clinical and laboratory sites. This protocol entitled "Protocol for the Diabetes Technology Society Blood Glucose Monitor System Surveillance Program" is attached as supplementary material. This program is needed because currently once a BGMS product has been cleared for use by the FDA, no systematic postmarket Surveillance Program exists that can monitor analytical performance and detect potential problems. This protocol will allow identification of inaccurate and unreliable BGMSs currently available on the US market. The DTS Surveillance Program will provide BGMS manufacturers a benchmark to understand the postmarket analytical performance of their products. Furthermore, patients, health care professionals, payers, and regulatory agencies will be able to use the results of the study to make informed decisions to, respectively, select, prescribe, finance, and regulate BGMSs on the market. © 2015 Diabetes Technology Society.

  10. Development of the Diabetes Technology Society Blood Glucose Monitor System Surveillance Protocol

    Science.gov (United States)

    Klonoff, David C.; Lias, Courtney; Beck, Stayce; Parkes, Joan Lee; Kovatchev, Boris; Vigersky, Robert A.; Arreaza-Rubin, Guillermo; Burk, Robert D.; Kowalski, Aaron; Little, Randie; Nichols, James; Petersen, Matt; Rawlings, Kelly; Sacks, David B.; Sampson, Eric; Scott, Steve; Seley, Jane Jeffrie; Slingerland, Robbert; Vesper, Hubert W.

    2015-01-01

    Background: Inaccurate blood glucsoe monitoring systems (BGMSs) can lead to adverse health effects. The Diabetes Technology Society (DTS) Surveillance Program for cleared BGMSs is intended to protect people with diabetes from inaccurate, unreliable BGMS products that are currently on the market in the United States. The Surveillance Program will provide an independent assessment of the analytical performance of cleared BGMSs. Methods: The DTS BGMS Surveillance Program Steering Committee included experts in glucose monitoring, surveillance testing, and regulatory science. Over one year, the committee engaged in meetings and teleconferences aiming to describe how to conduct BGMS surveillance studies in a scientifically sound manner that is in compliance with good clinical practice and all relevant regulations. Results: A clinical surveillance protocol was created that contains performance targets and analytical accuracy-testing studies with marketed BGMS products conducted by qualified clinical and laboratory sites. This protocol entitled “Protocol for the Diabetes Technology Society Blood Glucose Monitor System Surveillance Program” is attached as supplementary material. Conclusion: This program is needed because currently once a BGMS product has been cleared for use by the FDA, no systematic postmarket Surveillance Program exists that can monitor analytical performance and detect potential problems. This protocol will allow identification of inaccurate and unreliable BGMSs currently available on the US market. The DTS Surveillance Program will provide BGMS manufacturers a benchmark to understand the postmarket analytical performance of their products. Furthermore, patients, health care professionals, payers, and regulatory agencies will be able to use the results of the study to make informed decisions to, respectively, select, prescribe, finance, and regulate BGMSs on the market. PMID:26481642

  11. Environmental Surveillance System To Track Wild Poliovirus Transmission

    Science.gov (United States)

    Deshpande, Jagadish M.; Shetty, Sushmitha J.; Siddiqui, Zaeem A.

    2003-01-01

    Eradication of poliomyelitis from large metropolis cities in India has been difficult due to high population density and the presence of large urban slums. Three paralytic poliomyelitis cases were reported in Mumbai, India, in 1999 and 2000 in spite of high immunization coverage and good-quality supplementary immunization activities. We therefore established a systematic environmental surveillance study by weekly screening of sewage samples from three high-risk slum areas to detect the silent transmission of wild poliovirus. In 2001, from among the 137 sewage samples tested, wild poliovirus type 1 was isolated from 35 and wild poliovirus type 3 was isolated from 1. Acute flaccid paralysis (AFP) surveillance indicated one case of paralytic poliomyelitis from the city. Phylogenetic analysis with complete VP1 sequences revealed that the isolates from environmental samples belonged to four lineages of wild polioviruses recently isolated from poliomyelitis cases in Uttar Pradesh and not to those previously isolated from AFP cases in Mumbai. Wild poliovirus thus introduced caused one case of paralytic poliomyelitis. The virus was detected in environmental samples 3 months before. It was found that wild polioviruses introduced several times during the year circulated in Mumbai for a limited period before being eliminated. Environmental surveillance was found to be sensitive for the detection of wild poliovirus silent transmission. Nucleotide sequence analysis helped identify wild poliovirus reservoir areas. PMID:12732567

  12. Implementation of Rotavirus Surveillance and Vaccine Introduction - World Health Organization African Region, 2007-2016.

    Science.gov (United States)

    Mwenda, Jason M; Burke, Rachel M; Shaba, Keith; Mihigo, Richard; Tevi-Benissan, Mable Carole; Mumba, Mutale; Biey, Joseph Nsiari-Muzeyi; Cheikh, Dah; Poy MSc, Alain; Zawaira, Felicitas R; Aliabadi, Negar; Tate, Jacqueline E; Hyde, Terri; Cohen, Adam L; Parashar, Umesh D

    2017-11-03

    Rotavirus is a leading cause of severe pediatric diarrhea globally, estimated to have caused 120,000 deaths among children aged rotavirus vaccination for all infants worldwide (2). Two rotavirus vaccines are currently licensed globally: the monovalent Rotarix vaccine (RV1, GlaxoSmithKline; 2-dose series) and the pentavalent RotaTeq vaccine (RV5, Merck; 3-dose series). This report describes progress of rotavirus vaccine introduction (3), coverage (using estimates from WHO and the United Nations Children's Fund [UNICEF]) (4), and impact on pediatric diarrhea hospitalizations in the WHO African Region. By December 2016, 31 (66%) of 47 countries in the WHO African Region had introduced rotavirus vaccine, including 26 that introduced RV1 and five that introduced RV5. Among these countries, rotavirus vaccination coverage (completed series) was 77%, according to WHO/UNICEF population-weighted estimates. In 12 countries with surveillance data available before and after vaccine introduction, the proportion of pediatric diarrhea hospitalizations that were rotavirus-positive declined 33%, from 39% preintroduction to 26% following rotavirus vaccine introduction. These results support introduction of rotavirus vaccine in the remaining countries in the region and continuation of rotavirus surveillance to monitor impact.

  13. VigilAgent for the development of agent-based multi-robot surveillance systems

    OpenAIRE

    Gascueña Noheda, José Manuel; Navarro Martínez, Elena María; Fernández Caballero, Antonio

    2011-01-01

    Usually, surveillance applications are developed following an ad-hoc approach instead of using a methodology to guide stakeholders in achieving quality standards expected from commercial software. To solve this gap, our conjecture is that surveillance applications can be fully developed from their initial design stages by means of agent-based methodologies. Specifically, this paper describes the experience and the results of using a multi-agent systems approach according to the process provid...

  14. The Marine Corps Needs a Targeting, Sensors, and Surveillance Systems Operational Integration and Support Team

    Science.gov (United States)

    2010-03-02

    triggerman is probably still close ; lately all IEDs in the area have been initiated via command-wire. The squad leader sets a cordon, ensures an IED 9...Operational Surveillance System (G-BOSS) with a Class IIIb laser pointer. This class of laser requires users to receive a laser safety class...2) The Keyhole kit of surveillance equipment. Designed to provide “snipers with an increased capability to visually detect the enemy emplacing IEDs

  15. Evaluation of Syndromic Surveillance Systems in 6 US State and Local Health Departments.

    Science.gov (United States)

    Thomas, Mathew J; Yoon, Paula W; Collins, James M; Davidson, Arthur J; Mac Kenzie, William R

    Evaluating public health surveillance systems is critical to ensuring that conditions of public health importance are appropriately monitored. Our objectives were to qualitatively evaluate 6 state and local health departments that were early adopters of syndromic surveillance in order to (1) understand the characteristics and current uses, (2) identify the most and least useful syndromes to monitor, (3) gauge the utility for early warning and outbreak detection, and (4) assess how syndromic surveillance impacted their daily decision making. We adapted evaluation guidelines from the Centers for Disease Control and Prevention and gathered input from the Centers for Disease Control and Prevention subject matter experts in public health surveillance to develop a questionnaire. We interviewed staff members from a convenience sample of 6 local and state health departments with syndromic surveillance programs that had been in operation for more than 10 years. Three of the 6 interviewees provided an example of using syndromic surveillance to identify an outbreak (ie, cluster of foodborne illness in 1 jurisdiction) or detect a surge in cases for seasonal conditions (eg, influenza in 2 jurisdictions) prior to traditional, disease-specific systems. Although all interviewees noted that syndromic surveillance has not been routinely useful or efficient for early outbreak detection or case finding in their jurisdictions, all agreed that the information can be used to improve their understanding of dynamic disease control environments and conditions (eg, situational awareness) in their communities. In the jurisdictions studied, syndromic surveillance may be useful for monitoring the spread and intensity of large outbreaks of disease, especially influenza; enhancing public health awareness of mass gatherings and natural disasters; and assessing new, otherwise unmonitored conditions when real-time alternatives are unavailable. Future studies should explore opportunities to

  16. SCORPIO-VVER core monitoring and surveillance system with advanced capabilities

    International Nuclear Information System (INIS)

    Molnar, J.; Vocka, R.

    2009-01-01

    The SCORPIO-VVER system includes following features: 1) Validation of plant measurements and identification of sensor failures. 2) Optimum combination of measurements and calculations to obtain precise values of important parameters. 3) On-line 3D power distribution calculation with pin power reconstruction. 4) Limit checking and thermal margin calculation allowing for surveillance of VVER core limits such as DNBR, Sub-cooling margin, FdH and FQ peeking factors. 5) Integrated modules for monitoring fuel performance and coolant activity for identification of fuel failures. 6) Predictive capabilities and strategy planning, offering the possibility to check the consequences of operational manoeuvres in advance, prediction of critical parameters, etc. 7) Convenient monitoring of approach to criticality during reactor start-up. 8) Automated transition between cycles (fuel reload). The SCORPIO-VVER core monitoring system with its flexible and modular framework successfully responses to the plant operating needs and advances in nuclear fuel cycle strategies and fuel design. Modular framework allows for easy modifications of the system and implementation of new methods in physical modules. Even if the system is installed only on VVER-440 reactors, it could be adapted for VVER-1000 needs

  17. National laboratory-based surveillance system for antimicrobial resistance: a successful tool to support the control of antimicrobial resistance in the Netherlands.

    Science.gov (United States)

    Altorf-van der Kuil, Wieke; Schoffelen, Annelot F; de Greeff, Sabine C; Thijsen, Steven Ft; Alblas, H Jeroen; Notermans, Daan W; Vlek, Anne Lm; van der Sande, Marianne Ab; Leenstra, Tjalling

    2017-11-01

    An important cornerstone in the control of antimicrobial resistance (AMR) is a well-designed quantitative system for the surveillance of spread and temporal trends in AMR. Since 2008, the Dutch national AMR surveillance system, based on routine data from medical microbiological laboratories (MMLs), has developed into a successful tool to support the control of AMR in the Netherlands. It provides background information for policy making in public health and healthcare services, supports development of empirical antibiotic therapy guidelines and facilitates in-depth research. In addition, participation of the MMLs in the national AMR surveillance network has contributed to sharing of knowledge and quality improvement. A future improvement will be the implementation of a new semantic standard together with standardised data transfer, which will reduce errors in data handling and enable a more real-time surveillance. Furthermore, the scientific impact and the possibility of detecting outbreaks may be amplified by merging the AMR surveillance database with databases from selected pathogen-based surveillance programmes containing patient data and genotypic typing data.

  18. Pilot Implementation of Health Information Systems

    DEFF Research Database (Denmark)

    Bansler, Jørgen P.; Havn, Erling C.

    2009-01-01

    Pilot implementation is a powerful and widely used approach in identifying design flaws and implementation issues before the full-scale deployment of new health information systems. However, pilot implementations often fail in the sense that they say little about the usability and usefulness...... of the proposed system designs. This calls for studies that seek to uncover and analyze the reasons for failure, so that guidelines for conducting such pilots can be developed. In this paper, we present a qualitative field study of an ambitious, but unsuccessful pilot implementation of a Danish healthcare...... information system. Based on the findings from this study, we identify three main challenges: (1) defining an appropriate scope for pilot implementation, (2) managing the implementation process, and (3) ensuring commitment to the pilot. Finally, recommendations for future research and implications...

  19. Application of digital compression techniques to optical surveillance systems

    International Nuclear Information System (INIS)

    Johnson, C.S.

    1991-01-01

    There are many benefits to handling video images electronically, however, the amount of digital data in a normal video image is a major obstacle. The solution is to remove the high frequency and redundant information in a process that is referred to as compression. Compression allows the number of digital bits required for a given image to be reduced for more efficient storage or transmission of images. The next question is how much compression can be done without impairing the image quality beyond its usefulness for a given application. This paper discusses image compression that might be applied to provide useful images in unattended nuclear facility surveillance applications

  20. Status and prospects of the core surveillance system SCORPIO-VVER in Czech Republic and Slovakia

    International Nuclear Information System (INIS)

    Molnar, J.; Vocka, R.

    2011-01-01

    The SCORPIO-VVER core monitoring system has proved since the first installation at Dukovany NPP in 1999 to be a valuable tool for the reactor operators and reactor physicists. It is now installed on four units of Dukovany NPP (Czech Republic) and two units of Bohunice NPP (Slovak Republic) replacing the original Russian VK3 system. By both Czech and Slovak nuclear regulatory bodies it was licensed as a Technical Specification Surveillance tool. Since it's first installation, the development of SCORPIO-VVER system continues along with the changes in WWER reactors operation. The system is being adapted according the utility needs and several notable improvements in physical modules of the system were introduced. The latest most significant changes were done in connection with implementation of a new digital I and C system, loading of the optimized gadolinium bearing Gd2 fuel assemblies, improvements in the area of core design (neutron physics, core thermal hydraulics and fuel thermal mechanics), adaptation of the system to up-rated unit conditions, in design and methodology of the limit and technical specifications checking (implementation of the on-line shutdown margin calculation to the system) and improvements in the predictive part of the system (Strategy Generator). After the currently finished upgrades (Upgrade 2 at EBO Slovakia in 2009, Upgrade 5 at EDU Czech Republic in 2010) the SCORPIO-VVER is still in focus of Central European nuclear power plants with the road map of modification and implementation up to 2015. In April 2011 the Upgrade 3 at EBO Slovakia has been contracted to support the changed reactor technical specification and for support of the new type of fuel planned to load in 2012. During the summer of 2011 the discussions started with EDU NPP in Czech Republic regarding to the future development of the SCORPIO-VVER system up to 2015. Parallel with the support of current installations at NPPs the project of new installations is ongoing. During

  1. Testing a symptom-based surveillance system at high-profile gatherings as a preparatory measure for bioterrorism.

    Science.gov (United States)

    Osaka, K; Takahashi, H; Ohyama, T

    2002-12-01

    We tested symptom-based surveillance during the G8 conference in 2000 as a means of detecting outbreaks, including bio-terrorism attacks, promptly. Five categories of symptoms (skin and haemorrhagic, respiratory, gastrointestinal, neurological and unexplained) were adopted for the case definition of the surveillance. The surveillance began I week before the conference, and continued until 1 week after the conference ended. We could not detect any outbreaks during this surveillance. Compared to the existing diagnosis-based surveillance system, symptom-based surveillance has the advantages of timeliness and simplicity. However, poor specificity and difficulties in determining epidemic threshold were important limitations of this system. To increase the specificity of surveillance, it is essential to incorporate rapid laboratory diagnoses into the system.

  2. Nation-wide, web-based, geographic information system for the integrated surveillance and control of dengue fever in Mexico.

    Directory of Open Access Journals (Sweden)

    Juan Eugenio Hernández-Ávila

    Full Text Available Dengue fever incidence and its geographical distribution are increasing throughout the world. Quality and timely information is essential for its prevention and control. A web based, geographically enabled, dengue integral surveillance system (Dengue-GIS was developed for the nation-wide collection, integration, analysis and reporting of geo-referenced epidemiologic, entomologic, and control interventions data. Consensus in the design and practical operation of the system was a key factor for its acceptance. Working with information systems already implemented as a starting point facilitated its acceptance by officials and operative personnel. Dengue-GIS provides the geographical detail needed to plan, asses and evaluate the impact of control activities. The system is beginning to be adopted as a knowledge base by vector control programs. It is used to generate evidence on impact and cost-effectiveness of control activities, promoting the use of information for decision making at all levels of the vector control program. Dengue-GIS has also been used as a hypothesis generator for the academic community. This GIS-based model system for dengue surveillance and the experience gathered during its development and implementation could be useful in other dengue endemic countries and extended to other infectious or chronic diseases.

  3. Nation-wide, web-based, geographic information system for the integrated surveillance and control of dengue fever in Mexico.

    Science.gov (United States)

    Hernández-Ávila, Juan Eugenio; Rodríguez, Mario-Henry; Santos-Luna, René; Sánchez-Castañeda, Veronica; Román-Pérez, Susana; Ríos-Salgado, Víctor Hugo; Salas-Sarmiento, Jesús Alberto

    2013-01-01

    Dengue fever incidence and its geographical distribution are increasing throughout the world. Quality and timely information is essential for its prevention and control. A web based, geographically enabled, dengue integral surveillance system (Dengue-GIS) was developed for the nation-wide collection, integration, analysis and reporting of geo-referenced epidemiologic, entomologic, and control interventions data. Consensus in the design and practical operation of the system was a key factor for its acceptance. Working with information systems already implemented as a starting point facilitated its acceptance by officials and operative personnel. Dengue-GIS provides the geographical detail needed to plan, asses and evaluate the impact of control activities. The system is beginning to be adopted as a knowledge base by vector control programs. It is used to generate evidence on impact and cost-effectiveness of control activities, promoting the use of information for decision making at all levels of the vector control program. Dengue-GIS has also been used as a hypothesis generator for the academic community. This GIS-based model system for dengue surveillance and the experience gathered during its development and implementation could be useful in other dengue endemic countries and extended to other infectious or chronic diseases.

  4. The MIVS [Modular Integrated Video System] Image Processing System (MIPS) for assisting in the optical surveillance data review process

    International Nuclear Information System (INIS)

    Horton, R.D.

    1990-01-01

    The MIVS (Modular Integrated Video System) Image Processing System (MIPS) is designed to review MIVS surveillance data automatically and identify IAEA defined objects of safeguards interest. To achieve this, MIPS uses both digital image processing and neural network techniques to detect objects of safeguards interest in an image and assist an inspector in the review of the MIVS video tapes. MIPS must be ''trained'' i.e., given example images showing the objects that it must recognize, for each different facility. Image processing techniques are used to first identify significantly changed areas of the image. A neural network is then used to determine if the image contains the important object(s). The MIPS algorithms have demonstrated the capability to detect when a spent fuel shipping cask is present in an image after MIPS is properly trained to detect the cask. The algorithms have also demonstrated the ability to reject uninteresting background activities such as people and crane movement. When MIPS detects an important object, the corresponding image is stored to another media and later replayed for the inspector to review. The MIPS algorithms are being implemented in commercially available hardware: an image processing subsystem and an 80386 Personal Computer. MIPS will have a high-level easy-to-use system interface to allow inspectors to train MIPS on MIVS data from different facilities and on various safeguards significant objects. This paper describes the MIPS algorithms, hardware implementation, and system configuration. 3 refs., 10 figs

  5. The process monitoring computer system an integrated operations and safeguards surveillance system

    International Nuclear Information System (INIS)

    Liester, N.A.

    1995-01-01

    The use of the Process Monitoring Computer System (PMCS) at the Idaho Chemical Processing Plant (ICPP) relating to Operations and Safeguards concerns is discussed. Measures taken to assure the reliability of the system data are outlined along with the measures taken to assure the continuous availability of that data for use within the ICPP. The integration of process and safeguards information for use by the differing organizations is discussed. The PMCS successfully demonstrates the idea of remote Safeguards surveillance and the need for sharing of common information between different support organizations in an operating plant

  6. Implementing Business Intelligence System - Case Study

    Directory of Open Access Journals (Sweden)

    Yasser AL-HADAD

    2016-08-01

    Full Text Available Understanding and analysis data is essential for making decision within a system. Any analytical tasks can be implemented directly by the transactional system but it becomes more difficult as the transactional system grows. Analytical systems and their extension appear as a solution for complex and large datasets. We think that it's time for medium companies to get the benefit from such systems as analytical systems become more variant and in hand for every possible user. In this paper, we propose an architecture of analytical system that can adapt and integrate with existent transactional system of timber export company. The proposed analytical system should have the ability of implementing the tasks required by the decision makers of the system. Also, we try to explore the ability of SQL server of implementing our proposed architecture.

  7. Traumatic orodental injuries and the development of an orodental injury surveillance system: a pilot study in Victoria, Australia.

    Science.gov (United States)

    Tham, Rachel Catherine Anne; Cassell, Erin; Calache, Hanny

    2009-02-01

    Traumatic orodental injuries are common dental public health problems that have complex aetiology and significant impact on those affected. It is important to understand the frequency, pattern and causes of traumatic orodental injuries so that appropriate and effective treatment services are made available and injury prevention interventions are designed and implemented. The aims of this study were to measure the frequency, causes and patterns of traumatic orodental injuries in patients of all ages treated at the Royal Dental Hospital of Melbourne in Victoria, Australia, over a 12-month period and to investigate the feasibility of establishing an orodental injury surveillance system. For which, a retrospective audit of 304 patient records was undertaken and injury surveillance data were extracted and analysed. Males represented 67% of cases. Three-quarters of all cases were aged less than 24 years. The most frequent cause of orodental injury was falls from less than 1 m or being struck by or colliding with a person or object. Injuries occurred most commonly around the home, on the road, street or footpath, the sports ground and places for recreation and were most often associated with leisure and sports activities. Orodental injuries sustained in one traumatic incident were often multiple and serious. Many severe orodental trauma injury cases present at this public dental hospital are expensive to treat, require long-term management and may be preventable. The findings from this study have led to the development and planned implementation of an enhanced electronic orodental injury structured history form that incorporates the collection of key injury surveillance data. These prospective data are to be combined with injury surveillance data that are routinely collected by all Victorian public hospital emergency departments in order to improve understanding of the nature of orodental injuries impacting Victorian communities and assist with appropriate service

  8. Combining Google Earth and GIS mapping technologies in a dengue surveillance system for developing countries

    Directory of Open Access Journals (Sweden)

    Sobieszczyk Magdalena E

    2009-07-01

    Full Text Available Abstract Background Dengue fever is a mosquito-borne illness that places significant burden on tropical developing countries with unplanned urbanization. A surveillance system using Google Earth and GIS mapping technologies was developed in Nicaragua as a management tool. Methods and Results Satellite imagery of the town of Bluefields, Nicaragua captured from Google Earth was used to create a base-map in ArcGIS 9. Indices of larval infestation, locations of tire dumps, cemeteries, large areas of standing water, etc. that may act as larval development sites, and locations of the homes of dengue cases collected during routine epidemiologic surveying were overlaid onto this map. Visual imagery of the location of dengue cases, larval infestation, and locations of potential larval development sites were used by dengue control specialists to prioritize specific neighborhoods for targeted control interventions. Conclusion This dengue surveillance program allows public health workers in resource-limited settings to accurately identify areas with high indices of mosquito infestation and interpret the spatial relationship of these areas with potential larval development sites such as garbage piles and large pools of standing water. As a result, it is possible to prioritize control strategies and to target interventions to highest risk areas in order to eliminate the likely origin of the mosquito vector. This program is well-suited for resource-limited settings since it utilizes readily available technologies that do not rely on Internet access for daily use and can easily be implemented in many developing countries for very little cost.

  9. Description and implementation of a surveillance network for bluetongue in the Balkans and in adjoining areas of south-eastern Europe.

    Science.gov (United States)

    Dall'Acqua, F; Paladini, C; Meiswinkel, R; Savini, L; Calistri, P

    2006-01-01

    During the recent severe outbreaks of bluetongue (BT) in the Mediterranean Basin, the BT virus (BTV) spread beyond its historical limits into the Balkan region. One of the primary impacts of BT is the cessation in livestock trade which can have severe economic and social consequences. The authors briefly describe the development of the collaborative East-BTnet programme which aims to assist all affected and at-risk Balkan states and adjoining countries in the management of BT, and in the development of individual national surveillance systems. The beneficiary countries involved, and led by the World organisation for animal health (Office International des Epizooties) Collaborating Centre for veterinary training, epidemiology, food safety and animal welfare of the Istituto Zooprofilattico dell'Abruzzo e del Molise 'G. Caporale' in collaboration with the Institute for the Protection and the Security of the Citizen, the European Commission Joint Research Centre (IPSC-JRC), were Albania, Bosnia-Herzegovina, Bulgaria, Croatia, Cyprus, the Former Yugoslavia Republic of Macedonia, Kosovo, Malta, Romania, Serbia and Montenegro, Slovenia and Turkey. A regional web-based surveillance network is a valuable tool for controlling and managing transboundary animal diseases such as BT. Its implementation in the Balkan region and in adjoining areas of south-eastern Europe is described and discussed.

  10. The installation and performance test of the surveillance system for DUPIC facility

    International Nuclear Information System (INIS)

    Kim, Dong Young; Kim, Ho Dong; Cha, Hong Ryul

    2000-07-01

    We have developed the real time surveillance system, named by DSSS, for DUPIC test facility. The system acquires data from He-3 neutron monitors(DSNM) and CCD cameras to automatically diagnose the transportation status of nuclear material. This technical report shortly illustrates important features of hardware and software of the system

  11. The installation and performance test of the surveillance system for DUPIC facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Young; Kim, Ho Dong; Cha, Hong Ryul

    2000-07-01

    We have developed the real time surveillance system, named by DSSS, for DUPIC test facility. The system acquires data from He-3 neutron monitors(DSNM) and CCD cameras to automatically diagnose the transportation status of nuclear material. This technical report shortly illustrates important features of hardware and software of the system.

  12. Methodology implementation in order to evaluate the biological risks in the Centre for Research and Rehabilitation of Hereditary Ataxias of Cuba: a biosecurity surveillance method

    Directory of Open Access Journals (Sweden)

    Dailín Cobos Valdes

    2014-12-01

    Full Text Available Introduction: The Center for Research and Rehabilitation of Hereditary Ataxias faces biological risks. Nevertheless a Biosafety system was not yet implemented. Objective: To apply the methodology in order to evaluate these risks Materials and Methods: Interview with the researchers of the center and the use of the methodology for evaluating biological risks designed for Cobos, 2009. Results: Fifty-three biological risks were identified and evaluated, 32 as moderated, 18 as tolerable and 3 as trivial. Such classification are crucial to establish its management priorities and represent a way of surveillance in Biosafety field. Conclusion: The results of this research represent an essential factor for the Biosafety documentation development adapted to the Center and according to the legal basis in terms of biological safety in Cuba.

  13. Development of an electronic emergency department-based geo-information injury surveillance system in Hong Kong.

    Science.gov (United States)

    Chow, C B; Leung, M; Lai, Adela; Chow, Y H; Chung, Joanne; Tong, K M; Lit, Albert

    2012-06-01

    To describe the experience in the development of an electronic emergency department (ED)-based injury surveillance (IS) system in Hong Kong using data-mining and geo-spatial information technology (IT) for a Safe Community setup. This paper described the phased development of an emergency department-based IS system based on World Health Organization (WHO) injury surveillance Guideline to support safety promotion and injury prevention in a Safe Community in Hong Kong starting 2002. The initial ED data-based only collected data on name, sex, age, address, eight general categories of injury types (traffic, domestic, common assault, indecent assault, batter, industrial, self-harm and sports) and disposal from ED. Phase 1--manual data collection on International Classification of External Causes of Injury pre-event data; Phase 2--manual form was converted to electronic format using web-based data mining technology with built in data quality monitoring mechanism; Phase 3--integration of injury surveillance-data with in-patient hospital information; and Phase 4--geo-spatial information and body mapping were introduced to geo-code exact place of injury in an electronic map and site of injury on body map. It was feasible to develop a geo-spatial IS system at busy ED to collect valuable information for safety promotion and injury prevention at Safe Community setting. The keys for successful development and implementation involves engagement of all stakeholders at design and implementation of the system with injury prevention as ultimate goal, detail workflow planning at front end, support from the management, building on exiting system and appropriate utilisation of modern technology. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Desain dan Implementasi Aplikasi Video Surveillance System Berbasis Web-SIG

    Directory of Open Access Journals (Sweden)

    I M.O. Widyantara

    2015-06-01

    Full Text Available Video surveillance system (VSS is an monitoring system based-on IP-camera. VSS implemented in live streaming and serves to observe and monitor a site remotely. Typically, IP- camera in the VSS has a management software application. However, for ad hoc applications, where the user wants to manage VSS independently, application management software has become ineffective. In the IP-camera installation spread over a large area, an administrator would be difficult to describe the location of the IP-camera. In addition, monitoring an area of IP- Camera will also become more difficult. By looking at some of the flaws in VSS, this paper has proposed a VSS application for easy monitoring of each IP Camera. Applications that have been proposed to integrate the concept of web-based geographical information system with the Google Maps API (Web-GIS. VSS applications built with smart features include maps ip-camera, live streaming of events, information on the info window and marker cluster. Test results showed that the application is able to display all the features built well

  15. Successful Enterprise System Re-Implementation

    DEFF Research Database (Denmark)

    Svejvig, Per

    2017-01-01

    Achieving success in enterprise systems (ES) implementations is challenging. The success rate is not high in view of the sums invested by many organizations in these companywide systems. The literature is charged with reasons for unsuccessful implementations, such as a lack of top management...... support and insufficient change management. Contrary to this research, empirical data from an ES re-implementation in a Scandinavian high-tech company shows successful implementation despite many problematic shifts in outsourcing partners. Therefore, it is natural to ask: why was the re......-implementation of the ES at SCANDI successful despite the major troubles encountered during the project? Building an analysis based on ten Critical Success Factors (CSFs) combined with an investigation into the institutional structures at play, we present several reasons for the successful implementation. The CSF analysis...

  16. The insertion of the environmental health surveillance in the unified health system

    Directory of Open Access Journals (Sweden)

    Edenilo Baltazar Barreira Filho

    2012-03-01

    Full Text Available The integration of environmental monitoring activities in the Unified Health System (SUS shows some characteristics that differentiate it from the practice of epidemiological surveillance. This occurs mainly because much data on exposure to environmental factors is obtained outside the health sector and the adoption of actions that seek to control and/or prevent requires, in most cases, an intra andintersectoral understanding and articulation, since the health sector is not able, by itself, to provide answers to environmental health issues.In recent years, there has been an increasingly consolidation of the field of environmental health, which includes the area of public health, accustomed to scientific knowledge, to the formulation of public policies and the corresponding interventions (actions related to the interaction between human health and both natural and anthropic environmental factors, which determine, modulate and influence such interaction, in order to improve the quality of human life from the point of view of sustainability(1.As agreed at the Ist Seminar of the National Environmental Health, held in October 2005 and consolidated in the first National Conference on Environmental Health, held in December 2009, it is understood as an area of intersectoral and interdisciplinarypractice focused on the outcomes, in human health, of ecogeossocialrelations between man and environment(1.Accordingly, the Ministry of Health has been implementing, throughout the country, a Surveillance System in Environmental Health (SINVISA, seeking the improvement of this “model” of activities, establishing expertise into the three levels of government, aiming to consolidate the practice of Environmental Health within the SUS.Normative Instruction No. 1, March 7, 2005, creates SINVISA, establishes the area of action, the scope of the three levels of management within SUS and defines the Environmental Health Surveillance as a set of actions and services

  17. The systems engineering design of a smart Forward Operating Base surveillance system for forward operating base protection

    OpenAIRE

    Craft, Timothy L.

    2013-01-01

    Approved for public release; distribution is unlimited Forward operating bases are vulnerable to terrorist activity due to their location and limited resources. Threat awareness under these conditions is paramount to the safety of the personnel and to mission accomplishment. In the absence of the manpower required to maintain complete and continuous monitoring of the FOBs surroundings, an automated surveillance system is needed. The Smart FOB Surveillance System (SFSS) employs a multi-agen...

  18. On-line surveillance system for Borssele nuclear power plant monitoring and diagnostics

    International Nuclear Information System (INIS)

    Tuerkcan, E.; Ciftcioglu, Oe.

    1993-08-01

    An operating on-line surveillance and diagnostic system is described where information processing for monitoring and fault diagnosis and plant maintenance are addressed. The surveillance system by means of its realtime multiprocessing, multitasking execution capabilities can perform plant-wide and wide-range monitoring for enhanced plant safety and operational reliability as well as enhanced maintenance. At the same time the system provides the possibilities for goal-oriented research and development such as estimation, filtering, verification and validation and neural networks. (orig./HP)

  19. Implementing a new TLD system

    International Nuclear Information System (INIS)

    Rhea, T.A.

    1988-01-01

    Martin Marietta Energy Systems will soon be issuing new personnel dosimeters at four of their five Department of Energy (DOE) facilities, The Piketon, Ohio uranium enrichment facility is not included in this dosimetry upgrade program. This talk will focus on the ORNL perspective of this program, especially the new beta-gamma dosimeter. Neutron dosimetry will be discussed briefly. The objective of this upgrade is to put in place a state-of-the-art personnel dosimetry system and to meet the recent DOE Laboratory Accreditation Program performance criteria. Processing such a large number of dosimeters will require stringent quality controls. Approximately 18,000 beta-gamma dosimeters are scheduled for issue in January 1989. 15 figs

  20. Introduction of Service Systems Implementation

    Science.gov (United States)

    Demirkan, Haluk; Spohrer, James C.; Krishna, Vikas

    Services systems can range from an individual to a firm to an entire nation. They can also be nested and composed of other service systems. They are configurations of people, information, technology and organizations to co-create value between a service customer and a provider (Maglio et al. 2006; Spohrer et al. 2007). While these configurations can take many, potentially infinite, forms, they can be optimized for the subject service to eliminate unnecessary costs in the forms of redundancies, over allocation, etc. So what is an ideal configuration that a provider and a customer might strive to achieve? As much as it would be nice to have a formula for such configurations, experiences that are result of engagement, are very different for each value co-creation configurations. The variances and dynamism of customer provider engagements result in potentially infinite types and numbers of configurations in today's global economy.

  1. HIV test offers and acceptance: New York State findings from the behavioral risk factor surveillance system and the National HIV behavioral surveillance, 2011-2012.

    Science.gov (United States)

    John Leung, Shu-Yin; Sinclair, Amber H; Battles, Haven B; Swain, Carol-Ann E; French, Patrick Tyler; Anderson, Bridget J; Sowizral, Mycroft J; Ruberto, Rachael; Brissette, Ian; Lillquist, Patricia; Smith, Lou C

    2015-01-01

    The New York State HIV testing law requires that patients aged 13-64 years be offered HIV testing in health care settings. We investigated the extent to which HIV testing was offered and accepted during the 24 months after law enactment. We added local questions to the Behavioral Risk Factor Surveillance System (BRFSS) and the National HIV Behavioral Surveillance (NHBS) surveys asking respondents aged 18-64 years whether they were offered an HIV test in health care settings, and whether they had accepted testing. Statewide prevalence estimates of test offers and acceptance were obtained from a combined 2011-2012 BRFSS sample (N = 6,223). Local estimates for 2 high-risk populations were obtained from NHBS 2011 men who have sex with men (N = 329) and 2012 injection drug users (N = 188) samples. BRFSS data showed that 73% of New Yorkers received care in any health care setting in the past 12 months, of whom 25% were offered an HIV test. Sixty percent accepted the test when offered. The levels of test offer increased from 20% to 29% over time, whereas acceptance levels decreased from 68% to 53%. NHBS data showed that 81% of men who have sex with men received care, of whom 43% were offered an HIV test. Eighty-eight percent accepted the test when offered. Eighty-five percent of injection drug users received care, of whom 63% were offered an HIV test, and 63% accepted the test when offered. We found evidence of partial and increasing implementation of the HIV testing law. Importantly, these studies demonstrated New Yorkers' willingness to accept an offered HIV test as part of routine care in health care settings.

  2. SMART VIDEO SURVEILLANCE SYSTEM FOR VEHICLE DETECTION AND TRAFFIC FLOW CONTROL

    Directory of Open Access Journals (Sweden)

    A. A. SHAFIE

    2011-08-01

    Full Text Available Traffic signal light can be optimized using vehicle flow statistics obtained by Smart Video Surveillance Software (SVSS. This research focuses on efficient traffic control system by detecting and counting the vehicle numbers at various times and locations. At present, one of the biggest problems in the main city in any country is the traffic jam during office hour and office break hour. Sometimes it can be seen that the traffic signal green light is still ON even though there is no vehicle coming. Similarly, it is also observed that long queues of vehicles are waiting even though the road is empty due to traffic signal light selection without proper investigation on vehicle flow. This can be handled by adjusting the vehicle passing time implementing by our developed SVSS. A number of experiment results of vehicle flows are discussed in this research graphically in order to test the feasibility of the developed system. Finally, adoptive background model is proposed in SVSS in order to successfully detect target objects such as motor bike, car, bus, etc.

  3. DIAGNOSTIC OF SYSTEM OF FOOD AND NUTRITIONAL SURVEILLANCE IN A BASIC HEALTH UNIT - CUIABÁ/MT.

    Directory of Open Access Journals (Sweden)

    Amélia Dreyer Machado

    2011-01-01

    Full Text Available The System of Food and Nutritional Surveillance (SFNS is a vigilance system that stores information about population feeding and nutrition and also data about the nutritional conditions that can affect their health. The aim of this study, therefore, was to diagnose the reality of SFNS in the Basic Health Unit (BHU Despraiado I / Cuiabá-MT. Based on previously prepared forms that were created for the Family Health Team (FHT and the program technical manager, and in information available in the BHU registration cadastres, data collection happened in August 2010. The SFNS at the studied BHU began in 2007, being detected incomplete and inconsistent data in 43 forms, with a coverage of 0% of the related group. Feeling unable to implement the SFNS relevant actions, the FHT questions the lack of feedback to the community concerning to improvements in their dietary pattern. In turn, the SFNS technical manager attaches to BHU the existing flaws concerning to low coverage and inconsistent data. It was observed, therefore, the great importance of capacitating the FHT in order to increase the coverage and quality of data in forms filling out.

  4. Evaluation of a Spotted Fever Group Rickettsia Public Health Surveillance System in Tennessee.

    Science.gov (United States)

    Fill, Mary-Margaret A; Moncayo, Abelardo C; Bloch, Karen C; Dunn, John R; Schaffner, William; Jones, Timothy F

    2017-09-01

    Spotted fever group (SFG) rickettsioses are endemic in Tennessee, with ∼2,500 cases reported during 2000-2012. Because of this substantial burden of disease, we performed a three-part evaluation of Tennessee's routine surveillance for SFG rickettsioses cases and deaths to assess the system's effectiveness. Tennessee Department of Health (TDH) SFG rickettsioses surveillance records were matched to three patient series: 1) patients with positive serologic specimens from a commercial reference laboratory during 2010-2011, 2) tertiary medical center patients with positive serologic tests during 2007-2013, and 3) patients identified from death certificates issued during 1995-2014 with SFG rickettsiosis-related causes of death. Chart reviews were performed and patients were classified according to the Council of State and Territorial Epidemiologists' case definition. Of 254 SFG Rickettsia -positive serologic specimens from the reference laboratory, 129 (51%) met the case definition for confirmed or probable cases of rickettsial disease after chart review. The sensitivity of the TDH surveillance system to detect cases was 45%. Of the 98 confirmed or probable cases identified from the medical center, the sensitivity of the TDH surveillance system to detect cases was 34%. Of 27 patients identified by death certificates, 12 (44%) were classified as confirmed or probable cases; four (33%) were reported to TDH, but none were correctly identified as deceased. Cases of SFG rickettsioses were underreported and fatalities not correctly identified. Efforts are needed to improve SFG rickettsiosis surveillance in Tennessee.

  5. Extracting foreground ensemble features to detect abnormal crowd behavior in intelligent video-surveillance systems

    Science.gov (United States)

    Chan, Yi-Tung; Wang, Shuenn-Jyi; Tsai, Chung-Hsien

    2017-09-01

    Public safety is a matter of national security and people's livelihoods. In recent years, intelligent video-surveillance systems have become important active-protection systems. A surveillance system that provides early detection and threat assessment could protect people from crowd-related disasters and ensure public safety. Image processing is commonly used to extract features, e.g., people, from a surveillance video. However, little research has been conducted on the relationship between foreground detection and feature extraction. Most current video-surveillance research has been developed for restricted environments, in which the extracted features are limited by having information from a single foreground; they do not effectively represent the diversity of crowd behavior. This paper presents a general framework based on extracting ensemble features from the foreground of a surveillance video to analyze a crowd. The proposed method can flexibly integrate different foreground-detection technologies to adapt to various monitored environments. Furthermore, the extractable representative features depend on the heterogeneous foreground data. Finally, a classification algorithm is applied to these features to automatically model crowd behavior and distinguish an abnormal event from normal patterns. The experimental results demonstrate that the proposed method's performance is both comparable to that of state-of-the-art methods and satisfies the requirements of real-time applications.

  6. Twitter web-service for soft agent reporting in persistent surveillance systems

    Science.gov (United States)

    Rababaah, Haroun; Shirkhodaie, Amir

    2010-04-01

    Persistent surveillance is an intricate process requiring monitoring, gathering, processing, tracking, and characterization of many spatiotemporal events occurring concurrently. Data associated with events can be readily attained by networking of hard (physical) sensors. Sensors may have homogeneous or heterogeneous (hybrid) sensing modalities with different communication bandwidth requirements. Complimentary to hard sensors are human observers or "soft sensors" that can report occurrences of evolving events via different communication devices (e.g., texting, cell phones, emails, instant messaging, etc.) to the command control center. However, networking of human observers in ad-hoc way is rather a difficult task. In this paper, we present a Twitter web-service for soft agent reporting in persistent surveillance systems (called Web-STARS). The objective of this web-service is to aggregate multi-source human observations in hybrid sensor networks rapidly. With availability of Twitter social network, such a human networking concept can not only be realized for large scale persistent surveillance systems (PSS), but also, it can be employed with proper interfaces to expedite rapid events reporting by human observers. The proposed technique is particularly suitable for large-scale persistent surveillance systems with distributed soft and hard sensor networks. The efficiency and effectiveness of the proposed technique is measured experimentally by conducting several simulated persistent surveillance scenarios. It is demonstrated that by fusion of information from hard and soft agents improves understanding of common operating picture and enhances situational awareness.

  7. Real-Time FPGA-Based Object Tracker with Automatic Pan-Tilt Features for Smart Video Surveillance Systems

    Directory of Open Access Journals (Sweden)

    Sanjay Singh

    2017-05-01

    Full Text Available The design of smart video surveillance systems is an active research field among the computer vision community because of their ability to perform automatic scene analysis by selecting and tracking the objects of interest. In this paper, we present the design and implementation of an FPGA-based standalone working prototype system for real-time tracking of an object of interest in live video streams for such systems. In addition to real-time tracking of the object of interest, the implemented system is also capable of providing purposive automatic camera movement (pan-tilt in the direction determined by movement of the tracked object. The complete system, including camera interface, DDR2 external memory interface controller, designed object tracking VLSI architecture, camera movement controller and display interface, has been implemented on the Xilinx ML510 (Virtex-5 FX130T FPGA Board. Our proposed, designed and implemented system robustly tracks the target object present in the scene in real time for standard PAL (720 × 576 resolution color video and automatically controls camera movement in the direction determined by the movement of the tracked object.

  8. Remote-Reading Safety and Safeguards Surveillance System for 3013 Containers

    International Nuclear Information System (INIS)

    Lechelt, W. M.; Skorpik, J. R.; Silvers, K. L.; Szempruch, R. W.; Douglas, D. G.; Fein, K. O.

    2002-01-01

    At Hanford's Plutonium Finishing Plant (PFP), plutonium oxide is being loaded into stainless steel containers for long-term storage on the Hanford Site. These containers consist of two weld-sealed stainless steel cylinders nested one within the other. A third container holds the plutonium within the inner cylinder. This design meets the U.S. Department of Energy (DOE) storage standard, DOE-STD- 3013-2000, which anticipates a 50-year storage lifetime. The 3013 standard also requires a container surveillance program to continuously monitor pressure and to assure safeguards are adequate. However, the configuration of the container system makes using conventional measurement and monitoring methods difficult. To better meet the 3013 monitoring requirements, a team from Fluor Hanford (who manages the PFP), Pacific Northwest National Laboratory (PNNL), and Vista Engineering Technologies, LLC, developed a safer, cost-efficient, remote PFP 3013 container surveillance system. This new surveillance system is a combination of two successfully deployed technologies: (1) a magnetically coupled pressure gauge developed by Vista Engineering and (2) a radio frequency (RF) tagging device developed by PNNL. This system provides continuous, 100% monitoring of critical parameters with the containers in place, as well as inventory controls. The 3013 container surveillance system consists of three main elements: (1) an internal magnetic pressure sensor package, (2) an instrument pod (external electronics package), and (3) a data acquisition storage and display computer. The surveillance system described in this paper has many benefits for PFP and DOE in terms of cost savings and reduced personnel exposure. In addition, continuous safety monitoring (i.e., internal container pressure and temperature) of every container is responsible nuclear material stewardship and fully meets and exceeds DOE's Integrated Surveillance Program requirements

  9. 75 FR 81512 - Airworthiness Directives; Various Aviation Communication & Surveillance Systems (ACSS) Traffic...

    Science.gov (United States)

    2010-12-28

    ... units. This proposed AD would require upgrading software. This proposed AD results from reports of anomalies with TCAS units during a flight test over a high density airport. The TCAS units dropped several... & Surveillance Systems (ACSS) Traffic Alert and Collision Avoidance System (TCAS) units during a flight test over...

  10. Euratom multi-camera optical surveillance system (EMOSS) - a digital solution

    International Nuclear Information System (INIS)

    Otto, P.; Wagner, H.G.; Taillade, B.; Pryck, C. de.

    1991-01-01

    In 1989 the Euratom Safeguards Directorate of the Commission of the European Communities drew up functional and draft technical specifications for a new fully digital multi-camera optical surveillance system. HYMATOM of Castries designed and built a prototype unit for laboratory and field tests. This paper reports and system design and first test results

  11. Harmful Algal Bloom-Associated Illnesses in Humans and Dogs Identified Through a Pilot Surveillance System - New York, 2015.

    Science.gov (United States)

    Figgatt, Mary; Hyde, James; Dziewulski, David; Wiegert, Eric; Kishbaugh, Scott; Zelin, Grant; Wilson, Lloyd

    2017-11-03

    Cyanobacteria, also known as blue-green algae, are photosynthetic, aquatic organisms found in fresh, brackish, and marine water around the world (1). Rapid proliferation and accumulation of potentially toxin-producing cyanobacteria characterize one type of harmful algal bloom (HAB). HABs have the potential to cause illness in humans and animals (2,3); however, the epidemiology of these illnesses has not been well characterized. Statewide in 2015, a total of 139 HABs were identified in New York, 97 (70%) of which were confirmed through laboratory analysis; 77 independent beach closures were ordered at 37 beaches on 20 different bodies of water. To better characterize HAB-associated illnesses, during June-September 2015, the New York State Department of Health (NYSDOH) implemented a pilot surveillance system in 16 New York counties. Activities included the collection of data from environmental HAB reports, illness reports, poison control centers, and syndromic surveillance, and increased outreach to the public, health care providers, and veterinarians. During June-September, 51 HAB-associated illnesses were reported, including 35 that met the CDC case definitions*; 32 of the cases occurred in humans and three in dogs. In previous years, New York never had more than 10 HAB-associated illnesses reported statewide. The pilot surveillance results from 16 counties during a 4-month period suggest that HAB-associated illnesses might be more common than previously reported.

  12. Nadzor vazdušnog prostora pasivnim multisenzorskim sistemima / Air surveillance by passive multisensor systems

    Directory of Open Access Journals (Sweden)

    Miljko Erić

    2004-05-01

    Full Text Available Za sprovođenje savremenih operacija, kako na operativno-strategijskom, tako i na taktič kom nivou, izuzetno je važno da se obezbedi kontinuirani nadzor vazdušnog prostora. Poznato je da su aktivni radarski sistemi, na kojima se kod nas trenutno zasniva nadzor vazdušnog prostora, u ratnim uslovima veoma ranjivi i podložni elektronskim i borbenim dejstvima protivnika, što je u toku rata 1999. godine i praktično potvrđeno. Kao alternativa aktivnim radarskim sistemima nameće se koncept pasivnog nadzora vazdušnog prostora korišćenjem distribuiranih multisenzorskih sistema. Predmet širih istraživanja predstavljaju tehnička rešenja integrisanog multisenzorskog sistema za pasivan nadzor vazdušnog prostora, koji se sastoji od sledećih podsistema za nadzor vazdušnog prostora: na radio-gonimetarskom principu u frekvencijskom opsegu 20-3000 MHz, na zvukometrijskom principu, na principu vizuelnih osmatračkih stanica, na termovizijskom i televizijskom principu. U ovom radu analizirani su opšti principi pasivnog nadzora vazdušnog prostora multisenzorskim sistemima i predložena je tehnička koncepcija radio-goniometarskog i zvukometrijskog podsistema. / It is very important to provide continuous air surveillance in to realize modern operations on the operational-strategic level and tactical, as well. It is well known that active radar systems, on which air surveillance is based in our country, are very vulnerable in war times and susceptible to the electronic counter and combat attacks of the enemy, what is shown practically in 1999 war. Air surveillance by passive multi-sensor systems is a possible alternative to the air surveillance by the active radar systems. Subjects of our wider research are technical solutions of integrated multi-sensor systems for passive air surveillance which consists of the following subsystems: a subsystem for the air communication intelligence within the frequency range 20-3000 MHz based on intercept

  13. R and D study on on-line criticality surveillance system (V)

    International Nuclear Information System (INIS)

    Yamada, Sumasu

    2001-02-01

    In view of necessity and importance of criticality surveillance systems for ensuring the safety of nuclear fuel manufacturing and reprocessing plants, 5-year basic studies and 4 year R and D studies on an on-line criticality surveillance system were carried out since 1991. This report is a summary of these series of studies. Noticing that the signal from a neutron detector is random in principle, these series of studies aimed to accumulate knowledge for developing an inexpensive criticality surveillance system with quick response based on the Auto-Regressive Moving Average (ARMA) model identification algorithm. During five-year basic studies on criticality surveillance system since 1991, we obtained knowledge required for developing a criticality surveillance system based on the ARMA model identification algorithm through 1) studies on recursive ARMA model identification algorithms most appropriate for estimating subcriticality form time series data under a steady state condition, 2) studies on pre-processing of signal from neutron detectors, 3) developing a new recursive ARMA model identification algorithm with small time delay to estimate time-dependent subcriticality, 4) proposing a basic concept for the elements required for an on-line criticality surveillance system, and 5) numerical analysis of data from the DCA experiments. During next four-year R and D studies on a criticality surveillance system since 1996, we 1) proposed modules required for a no-line criticality surveillance system, 2) revealed effectiveness of a adaptive digital filter (ADF) algorithm, as an important redundancy to the recursive ARMA model identification algorithm to be used in the signal processing module through numerical analysis of real data, 3) proposed a module of the Feynman-α method over γ ray signal and a fast signal processing module for γ ray signal, 4) developed a line-noise removal filter(Notch filter) and revealed its effectiveness for the DCA data corrupted with power

  14. The information protection level assessment system implementation

    Science.gov (United States)

    Trapeznikov, E. V.

    2018-04-01

    Currently, the threat of various attacks increases significantly as automated systems become more widespread. On the basis of the conducted analysis the information protection level assessment system establishing objective was identified. The paper presents the information protection level assessment software implementation in the information system by applying the programming language C #. In conclusions the software features are identified and experimental results are represented.

  15. User resistance to information system implementations

    DEFF Research Database (Denmark)

    Campbell, Robert H.; Grimshaw, Mark

    2016-01-01

    Users often resist information system implementations and it has been established that this can cause an implementation to fail. In this paper, the user attitudes that can cause resistance are examined using an established attitude change theory from social and cognitive psychology: the Elaboration......-ranging study are presented that, in addition to supporting this argument, identifies and classifies 19 new heuristics and peripheral influences (in addition to the nine already known) that commonly, and adversely, affect user attitudes and responses to new information system implementations....

  16. Monitoring influenza activity in the United States: a comparison of traditional surveillance systems with Google Flu Trends.

    Directory of Open Access Journals (Sweden)

    Justin R Ortiz

    2011-04-01

    Full Text Available Google Flu Trends was developed to estimate US influenza-like illness (ILI rates from internet searches; however ILI does not necessarily correlate with actual influenza virus infections.Influenza activity data from 2003-04 through 2007-08 were obtained from three US surveillance systems: Google Flu Trends, CDC Outpatient ILI Surveillance Network (CDC ILI Surveillance, and US Influenza Virologic Surveillance System (CDC Virus Surveillance. Pearson's correlation coefficients with 95% confidence intervals (95% CI were calculated to compare surveillance data. An analysis was performed to investigate outlier observations and determine the extent to which they affected the correlations between surveillance data. Pearson's correlation coefficient describing Google Flu Trends and CDC Virus Surveillance over the study period was 0.72 (95% CI: 0.64, 0.79. The correlation between CDC ILI Surveillance and CDC Virus Surveillance over the same period was 0.85 (95% CI: 0.81, 0.89. Most of the outlier observations in both comparisons were from the 2003-04 influenza season. Exclusion of the outlier observations did not substantially improve the correlation between Google Flu Trends and CDC Virus Surveillance (0.82; 95% CI: 0.76, 0.87 or CDC ILI Surveillance and CDC Virus Surveillance (0.86; 95%CI: 0.82, 0.90.This analysis demonstrates that while Google Flu Trends is highly correlated with rates of ILI, it has a lower correlation with surveillance for laboratory-confirmed influenza. Most of the outlier observations occurred during the 2003-04 influenza season that was characterized by early and intense influenza activity, which potentially altered health care seeking behavior, physician testing practices, and internet search behavior.

  17. Monitoring Influenza Activity in the United States: A Comparison of Traditional Surveillance Systems with Google Flu Trends

    Science.gov (United States)

    Ortiz, Justin R.; Zhou, Hong; Shay, David K.; Neuzil, Kathleen M.; Fowlkes, Ashley L.; Goss, Christopher H.

    2011-01-01

    Background Google Flu Trends was developed to estimate US influenza-like illness (ILI) rates from internet searches; however ILI does not necessarily correlate with actual influenza virus infections. Methods and Findings Influenza activity data from 2003–04 through 2007–08 were obtained from three US surveillance systems: Google Flu Trends, CDC Outpatient ILI Surveillance Network (CDC ILI Surveillance), and US Influenza Virologic Surveillance System (CDC Virus Surveillance). Pearson's correlation coefficients with 95% confidence intervals (95% CI) were calculated to compare surveillance data. An analysis was performed to investigate outlier observations and determine the extent to which they affected the correlations between surveillance data. Pearson's correlation coefficient describing Google Flu Trends and CDC Virus Surveillance over the study period was 0.72 (95% CI: 0.64, 0.79). The correlation between CDC ILI Surveillance and CDC Virus Surveillance over the same period was 0.85 (95% CI: 0.81, 0.89). Most of the outlier observations in both comparisons were from the 2003–04 influenza season. Exclusion of the outlier observations did not substantially improve the correlation between Google Flu Trends and CDC Virus Surveillance (0.82; 95% CI: 0.76, 0.87) or CDC ILI Surveillance and CDC Virus Surveillance (0.86; 95%CI: 0.82, 0.90). Conclusions This analysis demonstrates that while Google Flu Trends is highly correlated with rates of ILI, it has a lower correlation with surveillance for laboratory-confirmed influenza. Most of the outlier observations occurred during the 2003–04 influenza season that was characterized by early and intense influenza activity, which potentially altered health care seeking behavior, physician testing practices, and internet search behavior. PMID:21556151

  18. [Surveillance system for adverse events following immunization against yellow fever in Burkina Faso in 2008. Good practice recommendations].

    Science.gov (United States)

    Yaméogo, T M; Breugelmans, J G; Kambou, J L; Badolo, O; Tiendrebéogo, S; Traoré, E; Avokey, F; Yactayo, S

    2009-08-01

    Yellow fever (YF) remains a public health problem in Africa. In 2007 and 2008, Togo, Senegal, Mali and Burkina Faso became the first countries to implement mass YF immunization campaigns within the framework of the Yellow Fever Initiative. The goal of this initiative led by the World Health Organization (WHO) and the United Nations Children's Fund (UNICEF) with the support of The Global Alliance for Vaccines and Immunization (GAVI) is to organize mass YF immunization campaigns in 12 African countries at high risk forYF transmission between 2006 and 2013. A total of 290 million USD have been allocated for vaccination of 180 million people with the highly effective attenuated 17DYF vaccine. Working in partnership with the WHO, the 12 member states are to identify and target high risk areas with the dual aim of preventing epidemics and increasing immunization coverage. Surveillance of adverse events following immunization (AEFI) is a mandatory component for organization of these campaigns. Purpose. The purpose of this article is to describe the AEFI surveillance system implemented in Burkina Faso in 2008. Methods. The strategy used in Burkina Faso was based on a combination of regular passive surveillance and active surveillance. General guidelines and related operational processes were established including reporting forms, investigation forms, and procedures for collection, storage and transport of biological specimens. Classification of cases was based on clearly defined criteria. Any patient meeting the defined criteria and requiring hospitalization was considered as a serious case. In addition to case definition criteria, serious cases were tracked according to presented signs and symptoms using a line-listing form at two university hospital centers in Ouagadougou and one regional hospital center. Emergency room admission records and patient charts were examined during the surveillance period (30 days after the end of the immunization campaign) and on

  19. Expanding severe acute respiratory infection (SARI) surveillance beyond influenza: The process and data from 1 year of implementation in Vietnam.

    Science.gov (United States)

    Alroy, Karen A; Do, Trang Thuy; Tran, Phu Dac; Dang, Tan Quang; Vu, Long Ngoc; Le, Nga Thi Hang; Dang, Anh Duc; Ngu, Nghia Duy; Ngo, Tu Huy; Hoang, Phuong Vu Mai; Phan, Lan Trong; Nguyen, Thuong Vu; Nguyen, Long Thanh; Nguyen, Thinh Viet; Vien, Mai Quang; Le, Huy Xuan; Dao, Anh The; Nguyen, Trieu Bao; Pham, Duoc Tho; Nguyen, Van Thi Tuyet; Pham, Thanh Ngoc; Phan, Binh Hai; Whitaker, Brett; Do, Thuy Thi Thu; Dao, Phuong Anh; Balajee, S Arunmozhi; Mounts, Anthony W

    2018-05-13

    In 2016, as a component of the Global Health Security Agenda, the Vietnam Ministry of Health expanded its existing influenza sentinel surveillance for severe acute respiratory infections (SARI) to include testing for 7 additional viral respiratory pathogens. This article describes the steps taken to implement expanded SARI surveillance in Vietnam and reports data from 1 year of expanded surveillance. The process of expanding the suite of pathogens for routine testing by real-time reverse transcriptase-polymerase chain reaction (rRT-PCR) included laboratory trainings, procurement/distribution of reagents, and strengthening and aligning SARI surveillance epidemiology practices at sentinel sites and regional institutes (RI). Surveillance data showed that of 4003 specimens tested by the RI laboratories, 20.2% (n = 810) were positive for influenza virus. Of the 3193 influenza-negative specimens, 41.8% (n = 1337) were positive for at least 1 non-influenza respiratory virus, of which 16.2% (n = 518), 13.4% (n = 428), and 9.6% (n = 308) tested positive for respiratory syncytial virus, rhinovirus, and adenovirus, respectively. The Government of Vietnam has demonstrated that expanding respiratory viral surveillance by strengthening and building upon an influenza platform is feasible, efficient, and practical. © 2018 The Authors. Influenza and Other Respiratory Viruses Published by John Wiley & Sons Ltd.

  20. Assessment of different surveillance systems for avian influenza in commercial poultry in Catalonia (North-Eastern Spain).

    Science.gov (United States)

    Alba, A; Casal, J; Napp, S; Martin, P A J

    2010-11-01

    Compulsory surveillance programmes for avian influenza (AI) have been implemented in domestic poultry and wild birds in all the European Member States since 2005. The implementation of these programmes is complex and requires a close evaluation. A good indicator to assess their efficacy is the sensitivity (Se) of the surveillance system. In this study, the sensitivities for different sampling designs proposed by the Spanish authorities for the commercial poultry population of Catalonia were assessed, using the scenario tree model methodology. These samplings were stratified throughout the territory of Spain and took into account the species, the types of production and their specific risks. The probabilities of detecting infection at different prevalences at both individual and holding level were estimated. Furthermore, those subpopulations that contributed more to the Se of the system were identified. The model estimated that all the designs met the requirements of the European Commission. The probability of detecting AI circulating in Catalonian poultry did not change significantly when the within-holding design prevalence varied from 30% to 10%. In contrast, when the among-holding design prevalence decreased from 5% to 1%, the probability of detecting AI was drastically reduced. The sampling of duck and goose holdings, and to a lesser extent the sampling of turkey and game bird holdings, increased the Se substantially. The Se of passive surveillance in chickens for highly pathogenic avian influenza (HPAI) and low pathogenicity avian influenza (LPAI) were also assessed. The probability of the infected birds manifesting apparent clinical signs and the awareness of veterinarians and farmers had great influence on the probability of detecting AI. In order to increase the probability of an early detection of HPAI in chicken, the probability of performing AI specific tests when AI is suspected would need to be increased. Copyright © 2010 Elsevier B.V. All rights

  1. Using an Emergency Department Syndromic Surveillance System to Evaluate Reporting of Potential Rabies Exposures, Illinois, 2013-2015.

    Science.gov (United States)

    Bemis, Kelley; Frias, Mabel; Patel, Megan Toth; Christiansen, Demian

    Mandatory reporting of potential rabies exposures and initiation of postexposure prophylaxis (PEP) allow local health authorities to monitor PEP administration for errors. Our objectives were to use an emergency department (ED) syndromic surveillance system to (1) estimate reporting compliance for exposure to rabies in suburban Cook County, Illinois, and (2) initiate interventions to improve reporting and reassess compliance. We queried ED records from 45 acute care hospitals in Cook County and surrounding areas from January 1, 2013, through June 30, 2015, for chief complaints or discharge diagnoses pertaining to rabies, PEP, or contact with a wild mammal (eg, bat, raccoon, skunk, fox, or coyote). We matched patients with ≥1 ED visit for potential rabies exposure to people with potential rabies exposure reported to the Cook County Department of Public Health. We considered nonmatches to have unreported exposures. We then initiated active surveillance in July 2015, disseminated education on reporting requirements in August and September 2015, and reassessed reporting completeness from July 2015 through February 2016. Of 248 patients with rabies-related ED visits from January 2013 through June 2015, 63 (25.4%) were reported. After interventions were implemented to increase reporting compliance, 53 of 98 (54.1%) patients with rabies-related ED visits from July 2015 through February 2016 were reported. Patients with ED visits for potential rabies exposure were twice as likely to be reported postintervention than preintervention (risk ratio = 2.1; 95% CI, 1.6-2.8). The volume of potential rabies exposure cases reported to the health department from July 2015 through February 2016 increased by 252% versus the previous year. Potential rabies exposures and PEP initiation are underreported in suburban Cook County. ED syndromic surveillance records can be used to estimate reporting compliance and conduct active surveillance.

  2. Sensitivity of the Dengue Surveillance System in Brazil for Detecting Hospitalized Cases

    Science.gov (United States)

    2016-01-01

    We evaluated the sensitivity of the dengue surveillance system in detecting hospitalized cases in ten capital cities in Brazil from 2008 to 2013 using a probabilistic record linkage of two independent information systems hospitalization (SIH-SUS) adopted as the gold standard and surveillance (SINAN). Sensitivity was defined as the proportion of cases reported to the surveillance system amid the suspected hospitalized cases registered in SIH-SUS. Of the 48,174 hospitalizations registered in SIH-SUS, 24,469 (50.7%) were reported and registered in SINAN, indicating an overall sensitivity of 50.8% (95%CI 50.3–51.2). The observed sensitivity for each of the municipalities included in the study ranged from 22.0% to 99.1%. The combination of the two data sources identified 71,161 hospitalizations, an increase of 97.0% over SINAN itself. Our results allowed establishing the proportion of underreported dengue hospitalizations in the public health system in Brazil, highlighting the use of probabilistic record linkage as a valuable tool for evaluating surveillance systems. PMID:27192405

  3. Intelligent agents for adaptive security market surveillance

    Science.gov (United States)

    Chen, Kun; Li, Xin; Xu, Baoxun; Yan, Jiaqi; Wang, Huaiqing

    2017-05-01

    Market surveillance systems have increasingly gained in usage for monitoring trading activities in stock markets to maintain market integrity. Existing systems primarily focus on the numerical analysis of market activity data and generally ignore textual information. To fulfil the requirements of information-based surveillance, a multi-agent-based architecture that uses agent intercommunication and incremental learning mechanisms is proposed to provide a flexible and adaptive inspection process. A prototype system is implemented using the techniques of text mining and rule-based reasoning, among others. Based on experiments in the scalping surveillance scenario, the system can identify target information evidence up to 87.50% of the time and automatically identify 70.59% of cases depending on the constraints on the available information sources. The results of this study indicate that the proposed information surveillance system is effective. This study thus contributes to the market surveillance literature and has significant practical implications.

  4. The Stevens Integrated Maritime Surveillance Forecast System: Expansion and Enhancement

    National Research Council Canada - National Science Library

    Bruno, Michael S; Blumberg, Alan F

    2006-01-01

    .... In the long-term, the observation and modeling systems will be linked in a unique fashion, whereby the model forecast system will be enhanced by data assimilation, and the observing system will...

  5. Utilization and viability of biologically-inspired algorithms in a dynamic multiagent camera surveillance system

    Science.gov (United States)

    Mundhenk, Terrell N.; Dhavale, Nitin; Marmol, Salvador; Calleja, Elizabeth; Navalpakkam, Vidhya; Bellman, Kirstie; Landauer, Chris; Arbib, Michael A.; Itti, Laurent

    2003-10-01

    In view of the growing complexity of computational tasks and their design, we propose that certain interactive systems may be better designed by utilizing computational strategies based on the study of the human brain. Compared with current engineering paradigms, brain theory offers the promise of improved self-organization and adaptation to the current environment, freeing the programmer from having to address those issues in a procedural manner when designing and implementing large-scale complex systems. To advance this hypothesis, we discus a multi-agent surveillance system where 12 agent CPUs each with its own camera, compete and cooperate to monitor a large room. To cope with the overload of image data streaming from 12 cameras, we take inspiration from the primate"s visual system, which allows the animal to operate a real-time selection of the few most conspicuous locations in visual input. This is accomplished by having each camera agent utilize the bottom-up, saliency-based visual attention algorithm of Itti and Koch (Vision Research 2000;40(10-12):1489-1506) to scan the scene for objects of interest. Real time operation is achieved using a distributed version that runs on a 16-CPU Beowulf cluster composed of the agent computers. The algorithm guides cameras to track and monitor salient objects based on maps of color, orientation, intensity, and motion. To spread camera view points or create cooperation in monitoring highly salient targets, camera agents bias each other by increasing or decreasing the weight of different feature vectors in other cameras, using mechanisms similar to excitation and suppression that have been documented in electrophysiology, psychophysics and imaging studies of low-level visual processing. In addition, if cameras need to compete for computing resources, allocation of computational time is weighed based upon the history of each camera. A camera agent that has a history of seeing more salient targets is more likely to obtain

  6. Guidelines for implementation of RCM on safety systems

    International Nuclear Information System (INIS)

    Kim, Tae Woon; Brijendra Singh.

    1996-04-01

    Reliability Centered Maintenance (RCM) methodology was originally developed by the commercial airlines industry in the early 1960s for identifying applicable and effective preventive maintenance tasks and as currently used in nuclear power industry. Effective maintenance of the systems at a nuclear power plant (NPP) is essential for its safe and reliable operation. Reliability Centered Maintenance at NPP is the program to assure that plant systems remain within an original design criteria and are not adversely affected during the plant life time. The aim of this report is to provide the guidelines to implement the RCM approach on NPP safety systems. Safety systems are usually standby and therefore, we need to periodically detect and repair failures that may have occurred since the previous activation or inspection the equipment. The RCM guidelines are intended to help identify the failure modes and related root causes and then decide the maintenance policies to achieve the high level of safety and reliability. The RCM is intended to improve or maintain high levels of system reliability and plant availability. Since the reliability of plant systems will be improved, the plant safety correspondingly will be increased. Another goal of RCM is to optimize the maintenance and surveillance tasks such that the overall level of resources required to accomplish essential tasks is kept to minimum. RCM also strives to eliminate unnecessary corrective maintenance and to select yet most cost-effective approach to maintenance, testing and inspection for system components. 9 refs. (Author) .new

  7. Development and implementation of integrated management system

    International Nuclear Information System (INIS)

    Tomov, E.; Nenkova, B.

    2013-01-01

    Risk Engineering Ltd is a private Bulgarian company in the field of scientific technical consultancy and engineering services, established in 1990. The aim of this report is to present the experience of Risk Engineering Ltd. in the development, implementation and operation of an integrated management system. The process of implementation of the system was completed at the end of 2011. In January 2012, the Risk Engineering Integrated Management System was certified by Lloyd's Register for compliance with standards ISO 9001:2008, ISO 140001:2004 and BS OHSAS 18001:2007

  8. Real time incorporation of random events in the reasoning of an on-line expert system. Application to the acoustic surveillance of vapor generators

    International Nuclear Information System (INIS)

    Launay, T.

    1989-03-01

    A study for improving an expert system applied in diagnostic assistance is presented. The results will be implemented in the vapor generators surveillance system. The aim of the work is to improve performances by reducing the time spent on reasoning and to strengthen the vigilance system. The investigation consists of four parts. In the first part, the state of the art of the different logics used in the artificial intelligence techniques is discussed, and the TMS and ATMS systems are presented. The second part of this thesis deals with problematics. Each point of the problem is studied and answered by applying the basic concepts used in the generation of on-line expert systems. In the third part, the on-line expert system generator ACTE is described. The ACTE aspects concerning the user, the inner structure and the functionality are considered. In the fourth part, an application to the surveillance of vapor generators and concluding remarks are presented [fr

  9. Quantitative and qualitative assessment of the bovine abortion surveillance system in France.

    Science.gov (United States)

    Bronner, Anne; Gay, Emilie; Fortané, Nicolas; Palussière, Mathilde; Hendrikx, Pascal; Hénaux, Viviane; Calavas, Didier

    2015-06-01

    Bovine abortion is the main clinical sign of bovine brucellosis, a disease of which France has been declared officially free since 2005. To ensure the early detection of any brucellosis outbreak, event-driven surveillance relies on the mandatory notification of bovine abortions and the brucellosis testing of aborting cows. However, the under-reporting of abortions appears frequent. Our objectives were to assess the aptitude of the bovine abortion surveillance system to detect each and every bovine abortion and to identify factors influencing the system's effectiveness. We evaluated five attributes defined by the U.S. Centers for Disease Control with a method suited to each attribute: (1) data quality was studied quantitatively and qualitatively, as this factor considerably influences data analysis and results; (2) sensitivity and representativeness were estimated using a unilist capture-recapture approach to quantify the surveillance system's effectiveness; (3) acceptability and simplicity were studied through qualitative interviews of actors in the field, given that the surveillance system relies heavily on abortion notifications by farmers and veterinarians. Our analysis showed that (1) data quality was generally satisfactory even though some errors might be due to actors' lack of awareness of the need to collect accurate data; (2) from 2006 to 2011, the mean annual sensitivity - i.e. the proportion of farmers who reported at least one abortion out of all those who detected such events - was around 34%, but was significantly higher in dairy than beef cattle herds (highlighting a lack of representativeness); (3) overall, the system's low sensitivity was related to its low acceptability and lack of simplicity. This study showed that, in contrast to policy-makers, most farmers and veterinarians perceived the risk of a brucellosis outbreak as negligible. They did not consider sporadic abortions as a suspected case of brucellosis and usually reported abortions only to

  10. Implementing polytope projects for smart systems

    CERN Document Server

    Iordache, Octavian

    2017-01-01

    This book presents a domain of extreme industrial and scientific interest: the study of smart systems and structures. It presents polytope projects as comprehensive physical and cognitive architectures that support the investigation, fabrication and implementation of smart systems and structures. These systems feature multifunctional components that can perform sensing, control, and actuation. In light of the fact that devices, tools, methodologies and organizations based on electronics and information technology for automation, specific to the third industrial revolution, are increasingly reaching their limits, it is essential that smart systems be implemented in industry. Polytope projects facilitate the utilization of smart systems and structures as key elements of the fourth industrial revolution. The book begins by presenting polytope projects as a reference architecture for cyber-physical systems and smart systems, before addressing industrial process synthesis in Chapter 2. Flow-sheet trees, cyclic sep...

  11. Project W-320, waste retrieval sluicing system: BIO/SER implementation matrices

    International Nuclear Information System (INIS)

    Bailey, J.W.

    1998-01-01

    This document provides verification that the safety related commitments specified in HNF-SD-WM-810-001, Addendum 1 for the Waste Retrieval Sluicing System, Project W-320 and Project W-320 Safety Evaluation Report (SER), have been implemented in the project hardware, procedures and administrative controls. Four appendices include matrices which show where the 810 commitments are implemented for limiting conditions of operation and surveillance requirements controls, administrative controls, defense-in-depth controls and controls discussed in 810 Addendum 1. A fifth appendix includes the implementation of Project W-320 SER issues and provisions

  12. Inventory of surveillance systems assessing dietary, physical activity and sedentary behaviours in Europe: a DEDIPAC study.

    NARCIS (Netherlands)

    Bel-Serrat, Silvia; Huybrechts, Inge; Thumann, Barbara F; Hebestreit, Antje; Abuja, Peter M; de Henauw, Stefaan; Dubuisson, Carine; Heuer, Thorsten; Murrin, Celine M; Lazzeri, Giacomo; van Rossum, Caroline; Andersen, Lene F; Szeklicki, Robert; Vioque, Jesús; Berry, Rachel; van der Ploeg, Hidde P; Ahrens, Wolfgang; Slimani, Nadia

    2017-01-01

    There is a need for harmonized public health surveillance systems to monitor regional variations and temporal trends of health behaviours and health outcomes and to align policies, action plans and recommendations in terms of healthy diet and physical (in)activity within Europe. We provide an

  13. Reassessing the WIC Effect: Evidence from the Pregnancy Nutrition Surveillance System

    Science.gov (United States)

    Joyce, Ted; Racine, Andrew; Yunzal-Butler, Cristina

    2008-01-01

    Recent analyses differ on how effective the Special Supplemental Nutrition Program for Women, Infants and Children (WIC) is at improving infant health. We use data from nine states that participate in the Pregnancy Nutrition Surveillance System to address limitations in previous work. With information on the mother's timing of WIC enrollment, we…

  14. A novel framework for intelligent surveillance system based on abnormal human activity detection in academic environments.

    Science.gov (United States)

    Al-Nawashi, Malek; Al-Hazaimeh, Obaida M; Saraee, Mohamad

    2017-01-01

    Abnormal activity detection plays a crucial role in surveillance applications, and a surveillance system that can perform robustly in an academic environment has become an urgent need. In this paper, we propose a novel framework for an automatic real-time video-based surveillance system which can simultaneously perform the tracking, semantic scene learning, and abnormality detection in an academic environment. To develop our system, we have divided the work into three phases: preprocessing phase, abnormal human activity detection phase, and content-based image retrieval phase. For motion object detection, we used the temporal-differencing algorithm and then located the motions region using the Gaussian function. Furthermore, the shape model based on OMEGA equation was used as a filter for the detected objects (i.e., human and non-human). For object activities analysis, we evaluated and analyzed the human activities of the detected objects. We classified the human activities into two groups: normal activities and abnormal activities based on the support vector machine. The machine then provides an automatic warning in case of abnormal human activities. It also embeds a method to retrieve the detected object from the database for object recognition and identification using content-based image retrieval. Finally, a software-based simulation using MATLAB was performed and the results of the conducted experiments showed an excellent surveillance system that can simultaneously perform the tracking, semantic scene learning, and abnormality detection in an academic environment with no human intervention.

  15. 77 FR 6000 - Airworthiness Directives; Aviation Communication & Surveillance Systems (ACSS) Traffic Alert and...

    Science.gov (United States)

    2012-02-07

    ... reduced surveillance aircraft tracks because of interference limiting. This AD requires upgrading software... FURTHER INFORMATION CONTACT: Abby Malmir, Aerospace Engineer, Systems and Equipment Branch, ANM-130L, FAA..., 2010) proposed to require upgrading software. The SNPRM proposed to require new updated software for...

  16. Revisiting the Rise of Electronic Nicotine Delivery Systems Using Search Query Surveillance.

    Science.gov (United States)

    Ayers, John W; Althouse, Benjamin M; Allem, Jon-Patrick; Leas, Eric C; Dredze, Mark; Williams, Rebecca S

    2016-06-01

    Public perceptions of electronic nicotine delivery systems (ENDS) remain poorly understood because surveys are too costly to regularly implement and, when implemented, there are long delays between data collection and dissemination. Search query surveillance has bridged some of these gaps. Herein, ENDS' popularity in the U.S. is reassessed using Google searches. ENDS searches originating in the U.S. from January 2009 through January 2015 were disaggregated by terms focused on e-cigarette (e.g., e-cig) versus vaping (e.g., vapers); their geolocation (e.g., state); the aggregate tobacco control measures corresponding to their geolocation (e.g., clean indoor air laws); and by terms that indicated the searcher's potential interest (e.g., buy e-cigs likely indicates shopping)-all analyzed in 2015. ENDS searches are rapidly increasing in the U.S., with 8,498,000 searches during 2014 alone. Increasingly, searches are shifting from e-cigarette- to vaping-focused terms, especially in coastal states and states where anti-smoking norms are stronger. For example, nationally, e-cigarette searches declined 9% (95% CI=1%, 16%) during 2014 compared with 2013, whereas vaping searches increased 136% (95% CI=97%, 186%), even surpassing e-cigarette searches. Additionally, the percentage of ENDS searches related to shopping (e.g., vape shop) nearly doubled in 2014, whereas searches related to health concerns (e.g., vaping risks) or cessation (e.g., quit smoking with e-cigs) were rare and declined in 2014. ENDS popularity is rapidly growing and evolving. These findings could inform survey questionnaire development for follow-up investigation and immediately guide policy debates about how the public perceives the health risks or cessation benefits of ENDS. Copyright © 2016 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  17. Ideology, Critique and Surveillance

    Directory of Open Access Journals (Sweden)

    Heidi Herzogenrath-Amelung

    2013-11-01

    Full Text Available The 2013 revelations concerning global surveillance programmes demonstrate in unprecedented clarity the need for Critical Theory of information and communication technologies (ICTs to address the mechanisms and implications of increasingly global, ubiquitous surveillance. This is all the more urgent because of the dominance of the “surveillance ideology” (the promise of security through surveillance that supports the political economy of surveillance. This paper asks which theoretical arguments and concepts can be useful for philosophically grounding a critique of this surveillance ideology. It begins by examining how the surveillance ideology works through language and introduces the concept of the ‘ideological packaging’ of ICTs to show how rhetoric surrounding the implementation of surveillance technologies reinforces the surveillance ideology. It then raises the problem of how ideology-critique can work if it relies on language itself and argues that Martin Heidegger’s philosophy can make a useful contribution to existing critical approaches to language.

  18. Developing a database management system to support birth defects surveillance in Florida.

    Science.gov (United States)

    Salemi, Jason L; Hauser, Kimberlea W; Tanner, Jean Paul; Sampat, Diana; Correia, Jane A; Watkins, Sharon M; Kirby, Russell S

    2010-01-01

    The value of any public health surveillance program is derived from the ways in which data are managed and used to improve the public's health. Although birth defects surveillance programs vary in their case volume, budgets, staff, and objectives, the capacity to operate efficiently and maximize resources remains critical to long-term survival. The development of a fully-integrated relational database management system (DBMS) can enrich a surveillance program's data and improve efficiency. To build upon the Florida Birth Defects Registry--a statewide registry relying solely on linkage of administrative datasets and unconfirmed diagnosis codes-the Florida Department of Health provided funding to the University of South Florida to develop and pilot an enhanced surveillance system in targeted areas with a more comprehensive approach to case identification and diagnosis confirmation. To manage operational and administrative complexities, a DBMS was developed, capable of managing transmission of project data from multiple sources, tracking abstractor time during record reviews, offering tools for defect coding and case classification, and providing reports to DBMS users. Since its inception, the DBMS has been used as part of our surveillance projects to guide the receipt of over 200 case lists and review of 12,924 fetuses and infants (with associated maternal records) suspected of having selected birth defects in over 90 birthing and transfer facilities in Florida. The DBMS has provided both anticipated and unexpected benefits. Automation of the processes for managing incoming case lists has reduced clerical workload considerably, while improving accuracy of working lists for field abstraction. Data quality has improved through more effective use of internal edits and comparisons with values for other data elements, while simultaneously increasing abstractor efficiency in completion of case abstraction. We anticipate continual enhancement to the DBMS in the future

  19. Effectiveness of community participation in a surveillance system initiative to prevent drowning in Thailand.

    Science.gov (United States)

    Sansiritaweesook, Getsara; Muangsom, Niramon; Kanato, Manop; Ratanasiri, Amornrat

    2015-03-01

    This study had a 2-group pre-post quasiexperimental design and was conducted in 2 selected areas of Ubon Ratchathani province, Thailand. The objective was to evaluate the extent to which the surveillance system that was developed helped in drowning prevention. The development process involved extensive participation from the community. System efficiency was evaluated, and the drowning rates were compared. The system demonstrated 82.8% system sensitivity and 87% positive-predictive value. There were 90.0% rescues with no injury during the study period. The relative risk of drowning injury suggests that the control area was at 5.6 times more at risk for drowning injury than the intervention area (95% CI = 1.58, 20.12). Local knowledge and participation from the community were found to be key issues in the success of the surveillance system, and such systems can be applied to other areas with similar problems. © 2013 APJPH.

  20. An Expert System And Simulation Approach For Sensor Management & Control In A Distributed Surveillance Network

    Science.gov (United States)

    Leon, Barbara D.; Heller, Paul R.

    1987-05-01

    A surveillance network is a group of multiplatform sensors cooperating to improve network performance. Network control is distributed as a measure to decrease vulnerability to enemy threat. The network may contain diverse sensor types such as radar, ESM (Electronic Support Measures), IRST (Infrared search and track) and E-0 (Electro-Optical). Each platform may contain a single sensor or suite of sensors. In a surveillance network it is desirable to control sensors to make the overall system more effective. This problem has come to be known as sensor management and control (SM&C). Two major facets of network performance are surveillance and survivability. In a netted environment, surveillance can be enhanced if information from all sensors is combined and sensor operating conditions are controlled to provide a synergistic effect. In contrast, when survivability is the main concern for the network, the best operating status for all sensors would be passive or off. Of course, improving survivability tends to degrade surveillance. Hence, the objective of SM&C is to optimize surveillance and survivability of the network. Too voluminous data of various formats and the quick response time are two characteristics of this problem which make it an ideal application for Artificial Intelligence. A solution to the SM&C problem, presented as a computer simulation, will be presented in this paper. The simulation is a hybrid production written in LISP and FORTRAN. It combines the latest conventional computer programming methods with Artificial Intelligence techniques to produce a flexible state-of-the-art tool to evaluate network performance. The event-driven simulation contains environment models coupled with an expert system. These environment models include sensor (track-while-scan and agile beam) and target models, local tracking, and system tracking. These models are used to generate the environment for the sensor management and control expert system. The expert system

  1. Video Surveillance using a Multi-Camera Tracking and Fusion System

    OpenAIRE

    Zhang , Zhong; Scanlon , Andrew; Yin , Weihong; Yu , Li; Venetianer , Péter L.

    2008-01-01

    International audience; Usage of intelligent video surveillance (IVS) systems is spreading rapidly. These systems are being utilized in a wide range of applications. In most cases, even in multi-camera installations, the video is processed independently in each feed. This paper describes a system that fuses tracking information from multiple cameras, thus vastly expanding its capabilities. The fusion relies on all cameras being calibrated to a site map, while the individual sensors remain lar...

  2. Surveillance of invasive diseases caused by Streptococcus pneumoniae in Italy: evolution of serotypes and antibiotic resistance in different age groups before and after implementation of PCV7

    Directory of Open Access Journals (Sweden)

    Fabio D’Ambrosio

    2013-04-01

    Full Text Available Background: PCV7 has been available in Italy since 2001, however only in 2005 national recommendations were issued and vaccination was implemented with different modalities by the Regions. Objectives: Aim of this study was to describe changes in serotype distribution and antibiotic susceptibility of S. pneumoniae from invasive pneumococcal diseases (IPD in the last decade. Study Design: S. pneumoniae isolates from IPD, collected through a national surveillance system, were serotyped and antibiotic susceptibility was determined by E-test. Data were analyzed according to age groups (5 years, >5-64 years, 65 years and to 3 time periods: prior, during and after PCV7 implementation (2001- 2003, 2006-2008 and 2009-2011. Results: The percentage of PCV7 serotypes (vaccine serotypes, VS decreased over the years not only in children (from 60% to 26% but also in the other age groups. Penicillin resistance was rather low in 2001-2003 (7-12%, but peaked in children in 2006-2008 (24%, and decreased in 2009-2011, while erythromycin resistance slightly decreased over the 3 periods. Conclusions: PCV7 use has largely impacted the epidemiology of S. pneumoniae in Italy, with a decrease in VS in all age groups.The impact of PCV 13, available in Italy since the end of 2010, requires future evaluations.

  3. Wisconsin’s Environmental Public Health Tracking Network: Information Systems Design for Childhood Cancer Surveillance

    Science.gov (United States)

    Hanrahan, Lawrence P.; Anderson, Henry A.; Busby, Brian; Bekkedal, Marni; Sieger, Thomas; Stephenson, Laura; Knobeloch, Lynda; Werner, Mark; Imm, Pamela; Olson, Joseph

    2004-01-01

    In this article we describe the development of an information system for environmental childhood cancer surveillance. The Wisconsin Cancer Registry annually receives more than 25,000 incident case reports. Approximately 269 cases per year involve children. Over time, there has been considerable community interest in understanding the role the environment plays as a cause of these cancer cases. Wisconsin’s Public Health Information Network (WI-PHIN) is a robust web portal integrating both Health Alert Network and National Electronic Disease Surveillance System components. WI-PHIN is the information technology platform for all public health surveillance programs. Functions include the secure, automated exchange of cancer case data between public health–based and hospital-based cancer registrars; web-based supplemental data entry for environmental exposure confirmation and hypothesis testing; automated data analysis, visualization, and exposure–outcome record linkage; directories of public health and clinical personnel for role-based access control of sensitive surveillance information; public health information dissemination and alerting; and information technology security and critical infrastructure protection. For hypothesis generation, cancer case data are sent electronically to WI-PHIN and populate the integrated data repository. Environmental data are linked and the exposure–disease relationships are explored using statistical tools for ecologic exposure risk assessment. For hypothesis testing, case–control interviews collect exposure histories, including parental employment and residential histories. This information technology approach can thus serve as the basis for building a comprehensive system to assess environmental cancer etiology. PMID:15471739

  4. Establishing an emergency department syndromic surveillance system to support the London 2012 Olympic and Paralympic Games.

    Science.gov (United States)

    Elliot, Alex J; Hughes, Helen E; Hughes, Thomas C; Locker, Thomas E; Shannon, Tony; Heyworth, John; Wapling, Andy; Catchpole, Mike; Ibbotson, Sue; McCloskey, Brian; Smith, Gillian E

    2012-12-01

    The London 2012 Olympic and Paralympic Games is a mass gathering event that will present a major public health challenge. The Health Protection Agency, in collaboration with the College of Emergency Medicine, has established the Emergency Department Sentinel Syndromic Surveillance System (EDSSS) to support the public health surveillance requirements of the Games. This feasibility study assesses the usefulness of EDSSS in monitoring indicators of disease in the community. Daily counts of anonymised attendance data from six emergency departments across England were analysed by patient demographics (age, gender, partial postcode), triage coding and diagnosis codes. Generic and specific syndromic indicators were developed using aggregations of diagnosis codes recorded during each attendance. Over 339,000 attendances were recorded (26 July 2010 to 25 July 2011). The highest attendances recorded on weekdays between 10:00 and 11:00 and on weekends between 12:00 and 13:00. The mean daily attendance per emergency department was 257 (range 38-435). Syndromic indicators were developed including: respiratory, gastrointestinal, cardiac, acute respiratory infection, gastroenteritis and myocardial ischaemia. Respiratory and acute respiratory infection indicators peaked during December 2010, concomitant with national influenza activity, as monitored through other influenza surveillance systems. The EDSSS has been established to provide an enhanced surveillance system for the London 2012 Olympics. Further validation of the data will be required; however, the results from this initial descriptive study demonstrate the potential for identifying unusual and/or severe outbreaks of infectious disease, or other incidents with public health impact, within the community.

  5. Implementing lean manufacturing system: ISM approach

    Directory of Open Access Journals (Sweden)

    Naveen Kumar

    2013-09-01

    Full Text Available Purpose: Lean Manufacturing System has emerged as an important area of research in Indian context. The requirement of Lean Manufacturing has increased due to defects in products (semi finished and finished and subsequent increase in cost. In this context, this study is an attempt to develop a structural model of the variables, important to implement Lean Manufacturing System in Indian automobile industry. Design/Methodology/Approach: Various variables of lean manufacturing system implementation have been identified from literature review and experts’ opinions. Contextual relationship among these identified variables has been set after carrying out brainstorming session. Further, classification of the variables has been carried out based upon the driving power and dependence. In addition to this, a structural model of variables to implement lean concept in Indian automobile industry has also been developed using Interpretive Structural Modeling (ISM technique. Questionnaire based survey has also been conducted to rank these variables. Findings: Eighteen variables have been identified from the literature and subsequent discussions with experts. Out of which, nine variables have been identified as dependent and nine variables have been identified as driver. No variable has been identified as linkage variable and autonomous variable. From the model developed, ‘Relative cost benefits’ has been identified as top level dependent variable and top management commitment as bottom level most independent variable. Research limitations/Implications: The model so developed is a hypothetical model based upon experts’ opinions. The conclusions so drawn may be further modified to apply in real situation. Practical implication: Clear understanding of interactions among these variables will help organizations to prioritize and manage these variables more effectively and efficiently to draw advantage from lean manufacturing system implementation

  6. System for unattended surveillance of nuclear reactor behavior

    International Nuclear Information System (INIS)

    Gonzalez, R.C.; Howington, L.C.

    1977-01-01

    A multivariate statistical pattern recognition system for reactor noise analysis is presented. The basis of the system is a transformation for decoupling correlated variables and algorithms for inferring probability density functions. The system is adaptable to a variety of statistical properties of the data, and it has learning, tracking, updating, and dimensionality reduction capabilities. System design emphasizes control of the false-alarm rate. Its abilities to learn normal patterns and to recognize deviations from these patterns were evaluated by experiments at the ORNL High-Flux Isotope Reactor. Power perturbations of less than 0.1% of the mean value in selected frequency ranges were readily detected by the pattern recognition system

  7. Demographic and health surveillance of mobile pastoralists in Chad: integration of biometric fingerprint identification into a geographical information system.

    Science.gov (United States)

    Weibel, Daniel; Schelling, Esther; Bonfoh, Bassirou; Utzinger, Jürg; Hattendorf, Jan; Abdoulaye, Mahamat; Madjiade, Toguina; Zinsstag, Jakob

    2008-11-01

    There is a pressing need for baseline demographic and health-related data to plan, implement and evaluate health interventions in developing countries, and to monitor progress towards international development goals. However, mobile pastoralists, i.e. people who depend on a livestock production system and follow their herds as they move, remain marginalized from rural development plans and interventions. The fact that mobile people are hard to reach and stay in contact with is a plausible reason why they are underrepresented in national censuses and/or alternative sequential sample survey systems. We present a proof-of-concept of monitoring highly mobile, pastoral people by recording demographic and health-related data from 933 women and 2020 children and establishing a biometric identification system (BIS) based on the registration and identification of digital fingerprints. Although only 22 women, representing 2.4% of the total registered women, were encountered twice in the four survey rounds, the approach implemented is shown to be feasible. The BIS described here is linked to a geographical information system to facilitate the creation of the first health and demographic surveillance system in a mobile, pastoralist setting. Our ultimate goal is to implement and monitor interventions with the "one health" concept, thus integrating and improving human, animal and ecosystem health.

  8. Demographic and health surveillance of mobile pastoralists in Chad: integration of biometric fingerprint identification into a geographical information system

    Directory of Open Access Journals (Sweden)

    Daniel Weibel

    2008-11-01

    Full Text Available There is a pressing need for baseline demographic and health-related data to plan, implement and evaluate health interventions in developing countries, and to monitor progress towards international development goals. However, mobile pastoralists, i.e. people who depend on a livestock production system and follow their herds as they move, remain marginalized from rural development plans and interventions. The fact that mobile people are hard to reach and stay in contact with is a plausible reason why they are underrepresented in national censuses and/or alternative sequential sample survey systems. We present a proof-of-concept of monitoring highly mobile, pastoral people by recording demographic and health-related data from 933 women and 2020 children and establishing a biometric identification system (BIS based on the registration and identification of digital fingerprints. Although only 22 women, representing 2.4% of the total registered women, were encountered twice in the four survey rounds, the approach implemented is shown to be feasible. The BIS described here is linked to a geographical information system to facilitate the creation of the first health and demographic surveillance system in a mobile, pastoralist setting. Our ultimate goal is to implement and monitor interventions with the “one health” concept, thus integrating and improving human, animal and ecosystem health.

  9. Priorities for antibiotic resistance surveillance in Europe

    DEFF Research Database (Denmark)

    Fluit, A. C.; van der Bruggen, J. T.; Aarestrup, Frank Møller

    2006-01-01

    Antibiotic resistance is an increasing global problem. Surveillance studies are needed to monitor resistance development, to guide local empirical therapy, and to implement timely and adequate countermeasures. To achieve this, surveillance studies must have standardised methodologies, be longitud......Antibiotic resistance is an increasing global problem. Surveillance studies are needed to monitor resistance development, to guide local empirical therapy, and to implement timely and adequate countermeasures. To achieve this, surveillance studies must have standardised methodologies...... to the various reservoirs of antibiotic-resistant bacteria, such as hospitalised patients, nursing homes, the community, animals and food. Two studies that could serve as examples of tailored programmes are the European Antimicrobial Resistance Surveillance System (EARSS), which collects resistance data during...... of antibiotic resistance....

  10. Surveillance and Outbreak Response Management System (SORMAS) to support the control of the Ebola virus disease outbreak in West Africa.

    Science.gov (United States)

    Fähnrich, C; Denecke, K; Adeoye, O O; Benzler, J; Claus, H; Kirchner, G; Mall, S; Richter, R; Schapranow, M P; Schwarz, N; Tom-Aba, D; Uflacker, M; Poggensee, G; Krause, G

    2015-03-26

    In the context of controlling the current outbreak of Ebola virus disease (EVD), the World Health Organization claimed that 'critical determinant of epidemic size appears to be the speed of implementation of rigorous control measures', i.e. immediate follow-up of contact persons during 21 days after exposure, isolation and treatment of cases, decontamination, and safe burials. We developed the Surveillance and Outbreak Response Management System (SORMAS) to improve efficiency and timeliness of these measures. We used the Design Thinking methodology to systematically analyse experiences from field workers and the Ebola Emergency Operations Centre (EOC) after successful control of the EVD outbreak in Nigeria. We developed a process model with seven personas representing the procedures of EVD outbreak control. The SORMAS system architecture combines latest In-Memory Database (IMDB) technology via SAP HANA (in-memory, relational database management system), enabling interactive data analyses, and established SAP cloud tools, such as SAP Afaria (a mobile device management software). The user interface consists of specific front-ends for smartphones and tablet devices, which are independent from physical configurations. SORMAS allows real-time, bidirectional information exchange between field workers and the EOC, ensures supervision of contact follow-up, automated status reports, and GPS tracking. SORMAS may become a platform for outbreak management and improved routine surveillance of any infectious disease. Furthermore, the SORMAS process model may serve as framework for EVD outbreak modeling.

  11. The Spanish system for the radiological surveillance and control of scrap and the products resulting from its processing

    International Nuclear Information System (INIS)

    Gil, E.

    2001-01-01

    Despite the fact that the use of radiation technologies has always been subjected to strict controls in most countries, the presence of radioactive materials in scrap has been detected relatively often in recent years. This has led to the implementation of a series of international initiatives aimed at detecting and preventing illicit international trafficking with radioactive material, intentional or otherwise. The Spanish iron and steel industry is one of the most important industrial sectors in the country, and depends to a large extent on the importing of a significant proportion of the scrap its uses as raw material. Experience has shown that that countries that import large quantities of scrap should complement the aforementioned international initiatives with others of national scope, in order to reduce the risks arising from the presence of radioactive material in scrap. In this context, the Spanish radiological protection authorities, along with the business associations involved in the metal recovery and smelting industry, have established a national system for the radiological surveillance and control of scrap and of the products resulting from its processing. The system consists of a set of legal bases, the installation of specific radiological surveillance equipment and the enhancement of other general purpose equipment that existed prior to these initiatives, the development of radiological training and information plans for the professionals involved in the metal recovery and smelting sectors and improvement to the national radiological emergency response system. (author)

  12. Digital dashboard design using multiple data streams for disease surveillance with influenza surveillance as an example.

    Science.gov (United States)

    Cheng, Calvin K Y; Ip, Dennis K M; Cowling, Benjamin J; Ho, Lai Ming; Leung, Gabriel M; Lau, Eric H Y

    2011-10-14

    Great strides have been made exploring and exploiting new and different sources of disease surveillance data and developing robust statistical methods for analyzing the collected data. However, there has been less research in the area of dissemination. Proper dissemination of surveillance data can facilitate the end user's taking of appropriate actions, thus maximizing the utility of effort taken from upstream of the surveillance-to-action loop. The aims of the study were to develop a generic framework for a digital dashboard incorporating features of efficient dashboard design and to demonstrate this framework by specific application to influenza surveillance in Hong Kong. Based on the merits of the national websites and principles of efficient dashboard design, we designed an automated influenza surveillance digital dashboard as a demonstration of efficient dissemination of surveillance data. We developed the system to synthesize and display multiple sources of influenza surveillance data streams in the dashboard. Different algorithms can be implemented in the dashboard for incorporating all surveillance data streams to describe the overall influenza activity. We designed and implemented an influenza surveillance dashboard that utilized self-explanatory figures to display multiple surveillance data streams in panels. Indicators for individual data streams as well as for overall influenza activity were summarized in the main page, which can be read at a glance. Data retrieval function was also incorporated to allow data sharing in standard format. The influenza surveillance dashboard serves as a template to illustrate the efficient synthesization and dissemination of multiple-source surveillance data, which may also be applied to other diseases. Surveillance data from multiple sources can be disseminated efficiently using a dashboard design that facilitates the translation of surveillance information to public health actions.

  13. Trust dynamics in a large system implementation

    DEFF Research Database (Denmark)

    Schlichter, Bjarne Rerup; Rose, Jeremy

    2013-01-01

    outcomes, but largely ignored the dynamics of trust relations. Giddens, as part of his study of modernity, theorises trust dynamics in relation to abstract social systems, though without focusing on information systems. We use Giddens’ concepts to investigate evolving trust relationships in a longitudinal......A large information systems implementation (such as Enterprise Resource Planning systems) relies on the trust of its stakeholders to succeed. Such projects impact diverse groups of stakeholders, each with their legitimate interests and expectations. Levels of stakeholder trust can be expected...... case analysis of a large Integrated Hospital System implementation for the Faroe Islands. Trust relationships suffered a serious breakdown, but the project was able to recover and meet its goals. We develop six theoretical propositions theorising the relationship between trust and project outcomes...

  14. Paper 5: Surveillance of multiple congenital anomalies: implementation of a computer algorithm in European registers for classification of cases

    DEFF Research Database (Denmark)

    Garne, Ester; Dolk, Helen; Loane, Maria

    2011-01-01

    Surveillance of multiple congenital anomalies is considered to be more sensitive for the detection of new teratogens than surveillance of all or isolated congenital anomalies. Current literature proposes the manual review of all cases for classification into isolated or multiple congenital anomal...

  15. Replicas Strategy and Cache Optimization of Video Surveillance Systems Based on Cloud Storage

    Directory of Open Access Journals (Sweden)

    Rongheng Li

    2018-04-01

    Full Text Available With the rapid development of video surveillance technology, especially the popularity of cloud-based video surveillance applications, video data begins to grow explosively. However, in the cloud-based video surveillance system, replicas occupy an amount of storage space. Also, the slow response to video playback constrains the performance of the system. In this paper, considering the characteristics of video data comprehensively, we propose a dynamic redundant replicas mechanism based on security levels that can dynamically adjust the number of replicas. Based on the location correlation between cameras, this paper also proposes a data cache strategy to improve the response speed of data reading. Experiments illustrate that: (1 our dynamic redundant replicas mechanism can save storage space while ensuring data security; (2 the cache mechanism can predict the playback behaviors of the users in advance and improve the response speed of data reading according to the location and time correlation of the front-end cameras; and (3 in terms of cloud-based video surveillance, our proposed approaches significantly outperform existing methods.

  16. MORTICIA, a statistical analysis software package for determining optical surveillance system effectiveness.

    Science.gov (United States)

    Ramkilowan, A.; Griffith, D. J.

    2017-10-01

    Surveillance modelling in terms of the standard Detect, Recognise and Identify (DRI) thresholds remains a key requirement for determining the effectiveness of surveillance sensors. With readily available computational resources it has become feasible to perform statistically representative evaluations of the effectiveness of these sensors. A new capability for performing this Monte-Carlo type analysis is demonstrated in the MORTICIA (Monte- Carlo Optical Rendering for Theatre Investigations of Capability under the Influence of the Atmosphere) software package developed at the Council for Scientific and Industrial Research (CSIR). This first generation, python-based open-source integrated software package, currently in the alpha stage of development aims to provide all the functionality required to perform statistical investigations of the effectiveness of optical surveillance systems in specific or generic deployment theatres. This includes modelling of the mathematical and physical processes that govern amongst other components of a surveillance system; a sensor's detector and optical components, a target and its background as well as the intervening atmospheric influences. In this paper we discuss integral aspects of the bespoke framework that are critical to the longevity of all subsequent modelling efforts. Additionally, some preliminary results are presented.

  17. The California All-sky Meteor Surveillance (CAMS) System

    Science.gov (United States)

    Gural, P. S.

    2011-01-01

    A unique next generation multi-camera, multi-site video meteor system is being developed and deployed in California to provide high accuracy orbits of simultaneously captured meteors. Included herein is a description of the goals, concept of operations, hardware, and software development progress. An appendix contains a meteor camera performance trade study made for video systems circa 2010.

  18. Postoperative Surgical Site Infections: Understanding the Discordance Between Surveillance Systems.

    Science.gov (United States)

    Ali-Mucheru, Mariam N; Seville, Maria T; Miller, Vickie; Sampathkumar, Priya; Etzioni, David A

    2018-04-18

    To characterize agreement in the ascertainment of surgical site infections (SSIs) between the National Surgical Quality Improvement Program (NSQIP), National Healthcare Safety Network (NHSN), and administrative data. The NSQIP, NHSN, and administrative data are the primary systems used to monitor and report SSIs for the purpose of quality control and benchmarking of hospitals and surgeons. These systems have different methods for identifying SSIs. We queried the NHSN, NSQIP, and administrative data systems for patients who had an operation at 1 of 4 hospitals within a single health system between January 2013 and September 2015. The detection of an SSI during a postoperative hospitalization was the outcome of analysis. Any SSI detected by one (or more) of these systems was analyzed by 2 reviewers to determine the presence of discrete elements of documentation constituting evidence of SSI. Concordance between the 3 systems (NHSN, NSQIP, and administrative data) was analyzed using Cohen's kappa. After application of appropriate exclusion criteria, a cohort of 9447 inpatient operations was analyzed. In total, 130 SSIs were detected by 1 or more of the 3 systems, with reported SSI rates of 0.5% (NHSN), 0.7% (administrative data), and 1.0% (NSQIP). Of these 130 SSIs, only 17 SSIs were reported by all 3 systems. The concordance between these 3 systems was moderate (kappa values NSQIP-NHSN = 0.50 [0.40-0.60], administrative-NHSN = 0.36 [0.24-0.47], and administrative-NSQIP = 0.47 [0.38-0.57]). Chart review found that reasons for discordance were related to issues of different criteria as well as inaccuracies. There is significant discordance in the determination of SSIs reported by the NHSN, NSQIP, and administrative data. The differences and limitations of each of these systems have to be recognized, especially when using these data for quality reports and pay for performance.

  19. A Master-Slave Surveillance System to Acquire Panoramic and Multiscale Videos

    Directory of Open Access Journals (Sweden)

    Yu Liu

    2014-01-01

    Full Text Available This paper describes a master-slave visual surveillance system that uses stationary-dynamic camera assemblies to achieve wide field of view and selective focus of interest. In this system, the fish-eye panoramic camera is capable of monitoring a large area, and the PTZ dome camera has high mobility and zoom ability. In order to achieve the precise interaction, preprocessing spatial calibration between these two cameras is required. This paper introduces a novel calibration approach to automatically calculate a transformation matrix model between two coordinate systems by matching feature points. In addition, a distortion correction method based on Midpoint Circle Algorithm is proposed to handle obvious horizontal distortion in the captured panoramic image. Experimental results using realistic scenes have demonstrated the efficiency and applicability of the system with real-time surveillance.

  20. Electronic surveillance systems in infection prevention: organizational support, program characteristics, and user satisfaction.

    Science.gov (United States)

    Grota, Patti G; Stone, Patricia W; Jordan, Sarah; Pogorzelska, Monika; Larson, Elaine

    2010-09-01

    The use of electronic surveillance systems (ESSs) is gradually increasing in infection prevention and control programs. Little is known about the characteristics of hospitals that have a ESS, user satisfaction with ESSs, and organizational support for implementation of ESSs. A total of 350 acute care hospitals in California were invited to participate in a Web-based survey; 207 hospitals (59%) agreed to participate. The survey included a description of infection prevention and control department staff, where and how they spent their time, a measure of organizational support for infection prevention and control, and reported experience with ESSs. Only 23% (44/192) of responding infection prevention and control departments had an ESS. No statistically significant difference was seen in how and where infection preventionists (IPs) who used an ESS and those who did not spend their time. The 2 significant predictors of whether an ESS was present were score on the Organizational Support Scale (odds ratio [OR], 1.10; 95% confidence interval [CI], 1.02-1.18) and hospital bed size (OR, 1.004; 95% CI, 1.00-1.007). Organizational support also was positively correlated with IP satisfaction with the ESS, as measured on the Computer Usability Scale (P = .02). Despite evidence that such systems may improve efficiency of data collection and potentially improve patient outcomes, ESSs remain relatively uncommon in infection prevention and control programs. Based on our findings, organizational support appears to be a major predictor of the presence, use, and satisfaction with ESSs in infection prevention and control programs.

  1. Electronic surveillance systems in infection prevention: Organizational support, program characteristics, and user satisfaction

    Science.gov (United States)

    Grota, Patti G.; Stone, Patricia W.; Jordan, Sarah; Pogorzelska, Monika; Larson, Elaine

    2012-01-01

    Background The use of electronic surveillance systems (ESSs) is gradually increasing in infection prevention and control programs. Little is known about the characteristics of hospitals that have a ESS, user satisfaction with ESSs, and organizational support for implementation of ESSs. Methods A total of 350 acute care hospitals in California were invited to participate in a Web-based survey; 207 hospitals (59%) agreed to participate. The survey included a description of infection prevention and control department staff, where and how they spent their time, a measure of organizational support for infection prevention and control, and reported experience with ESSs. Results Only 23% (44/192) of responding infection prevention and control departments had an ESS. No statistically significant difference was seen in how and where infection preventionists (IPs) who used an ESS and those who did not spend their time. The 2 significant predictors of whether an ESS was present were score on the Organizational Support Scale (odds ratio [OR], 1.10; 95% confidence interval [CI], 1.02-1.18) and hospital bed size (OR, 1.004; 95% CI, 1.00-1.007). Organizational support also was positively correlated with IP satisfaction with the ESS, as measured on the Computer Usability Scale (P = .02). Conclusion Despite evidence that such systems may improve efficiency of data collection and potentially improve patient outcomes, ESSs remain relatively uncommon in infection prevention and control programs. Based on our findings, organizational support appears to be a major predictor of the presence, use, and satisfaction with ESSs in infection prevention and control programs. PMID:20176411

  2. R and D study on on-line criticality surveillance system (IV)

    International Nuclear Information System (INIS)

    Yamada, Sumasu

    2000-02-01

    Developing an inexpensive on-line criticality surveillance system is required for ensuring the safety of nuclear fuel reprocessing plants. Based on the series of researches for five years, R and D study on On-line Criticality Surveillance system has been carried out since 1996. The concept of this Criticality Surveillance System is based on the Auto-Regressive Moving Average (ARMA) model identification algorithms to the time series of signal fluctuation of a neutron detector. We have proposed several new ideas of modification to the original design of the Criticality Surveillance System, and also reported some results of numerical analysis over the DCA experiments. In those days, DOS/V personal computers with Microsoft Windows have came into wide use instead of those based on the MS-DOS, which have been popular in Japan. NEC, a major maker of MS-DOS computers, stopped the production of MS-DOS computers and changed their management policy toward production of DOS/V personal computers. Our researches have been developed using MS-DOS computers. For the effective use of these important results, it became an urgent theme to transplant all programs developed on MS-DOS computers into computers with the OS, which is not easily affected by commercialism. Since the design concept should be based on high reliability, electromagnetic disturbance-free and high expandability, and also computers have achieved remarkably high performance as well as low price in these days, these computers should be used not only as a simple signal processing unit but also a totally integrated signal analyzing system along with conventional signal analyzing software in stead of IC chips with analyzing soft wares. This configuration enables us to easily introduce newly developed techniques and to provide supplement information. Then, this approach can enhance the reliability of the Criticality Surveillance System without addition of any special devices, and also provide the flexibility of the system

  3. SOA-surveillance Nederland

    NARCIS (Netherlands)

    Rijlaarsdam J; Bosman A; Laar MJW van de; CIE

    2000-01-01

    In May 1999 a working group was started to evaluate the current surveillance systems for sexually transmitted diseases (STD) and to make suggestions for a renewed effective and efficient STD surveillance system in the Netherlands. The surveillance system has to provide insight into the prevalence

  4. National Vital Statistics System (NVSS) - National Cardiovascular Disease Surveillance Data

    Data.gov (United States)

    U.S. Department of Health & Human Services — 2000 forward. NVSS is a secure, web-based data management system that collects and disseminates the Nation's official vital statistics. Indicators from this data...

  5. RTDS Implementation of Bornholm Power System

    DEFF Research Database (Denmark)

    Cha, Seung-Tae

    2010-01-01

    This report is a direct result of special Ph.D course(Distribution System Modeling and Analysis) as part of external stay, RTI, Canada to provide implementation procedures, the capability of the RTDS simulator in the area of distribution modeling, and supporting documentation for future research...

  6. Implementation of a Computerized Maintenance Management System

    Science.gov (United States)

    Shen, Yong-Hong; Askari, Bruce

    1994-01-01

    A primer Computerized Maintenance Management System (CMMS) has been established for NASA Ames pressure component certification program. The CMMS takes full advantage of the latest computer technology and SQL relational database to perform periodic services for vital pressure components. The Ames certification program is briefly described and the aspects of the CMMS implementation are discussed as they are related to the certification objectives.

  7. Using semantic technologies and the OSU ontology for modelling context and activities in multi-sensory surveillance systems

    Science.gov (United States)

    Gómez A, Héctor F.; Martínez-Tomás, Rafael; Arias Tapia, Susana A.; Rincón Zamorano, Mariano

    2014-04-01

    Automatic systems that monitor human behaviour for detecting security problems are a challenge today. Previously, our group defined the Horus framework, which is a modular architecture for the integration of multi-sensor monitoring stages. In this work, structure and technologies required for high-level semantic stages of Horus are proposed, and the associated methodological principles established with the aim of recognising specific behaviours and situations. Our methodology distinguishes three semantic levels of events: low level (compromised with sensors), medium level (compromised with context), and high level (target behaviours). The ontology for surveillance and ubiquitous computing has been used to integrate ontologies from specific domains and together with semantic technologies have facilitated the modelling and implementation of scenes and situations by reusing components. A home context and a supermarket context were modelled following this approach, where three suspicious activities were monitored via different virtual sensors. The experiments demonstrate that our proposals facilitate the rapid prototyping of this kind of systems.

  8. Implementation of an Electronic Medical Records System

    Science.gov (United States)

    2008-05-07

    Hartman, MAJ Roddex Barlow , CPT Christopher Besser and Capt Michael Emerson...thank you I am truly honored to call each of you my friends. Electronic... abnormal findings are addressed. 18 Electronic Medical Record Implementation Barriers of the Electronic Medical Records System There are several...examination findings • Psychological and social assessment findings N. The system provides a flexible mechanism for retrieval of encounter

  9. Respective influence of veterinarians and local institutional stakeholders on the event-driven surveillance system for bovine brucellosis in France.

    Science.gov (United States)

    Bronner, Anne; Morignat, Eric; Calavas, Didier

    2015-08-01

    The event-driven surveillance system for bovine brucellosis implemented in France aims to ensure the early detection of cases of bovine brucellosis, a disease of which the country has been declared free since 2005. It consists of mandatory notification of bovine abortions by farmers and veterinarians. However, as underlined by a previous qualitative study, several factors influence the decision-making process of actors in the field. This process is particularly influenced by the level of cooperation between institutional stakeholders in their département (a French département being an administrative and territorial unit), veterinarians and farmers. In this context, the objectives of this study were 1) to quantify the respective influence of veterinarians and all local institutional stakeholders on the proportion of notifying farmers and identify which actors have most influence on farmers' decisions; 2) to analyse whether the influence of veterinarians is correlated with that of local institutional stakeholders. In addition to factors relating to the farm itself (production type and herd size), the proportion of notifying farmers was influenced by the number of veterinarians per practice and the veterinary practice's membership of a technical association. This proportion was also influenced by unknown factors relating to the veterinary practice and, to a lesser extent, the département in which the farm was located. There was no correlation between variability in the proportion of notifying farmers among veterinary practices per département and the effect of the département itself. To our knowledge, this is the first study to quantify the influence of veterinarians and local institutional stakeholders on the notification process for a mandatory disease. In addition to carrying out regulatory interventions, veterinarians play a major role in encouraging farmers to participate in the surveillance systems. The results of this study, combined with a previous

  10. Experiences From Developing and Upgrading a Web-Based Surveillance System for Malaria Elimination in Cambodia.

    Science.gov (United States)

    Fu, Clementine; Lopes, Sérgio; Mellor, Steve; Aryal, Siddhi; Sovannaroth, Siv; Roca-Feltrer, Arantxa

    2017-06-14

    Strengthening the surveillance component is key toward achieving country-wide malaria elimination in Cambodia. A Web-based upgraded malaria information system (MIS) was deemed to essentially act as the central component for surveillance strengthening. New functionality (eg, data visualization) and operational (eg, data quality) attributes of the system received particular attention. However, building from the lessons learned in previous systems' developments, other aspects unique to Cambodia were considered to be equally important; for instance, feasibility issues, particularly at the field level (eg, user acceptability at various health levels), and sustainability needs (eg, long-term system flexibility). The Cambodian process of identifying the essential changes and critical attributes for this new information system can provide a model for other countries at various stages of the disease control and elimination continuum. Sharing these experiences not only facilitates the establishment of "best practices" but also accelerates global and regional malaria elimination efforts. In this article, Cambodia's experience in developing and upgrading its MIS to remain responsive to country-specific needs demonstrates the necessity for considering functionality, operationalization, feasibility, and sustainability of an information system in the context of malaria elimination. ©Clementine Fu, Sérgio Lopes, Steve Mellor, Siddhi Aryal, Siv Sovannaroth, Arantxa Roca-Feltrer. Originally published in JMIR Public Health and Surveillance (http://publichealth.jmir.org), 14.06.2017.

  11. Evaluation of a Broad-Spectrum Partially Automated Adverse Event Surveillance System: A Potential Tool for Patient Safety Improvement in Hospitals With Limited Resources.

    Science.gov (United States)

    Saikali, Melody; Tanios, Alain; Saab, Antoine

    2017-11-21

    The aim of the study was to evaluate the sensitivity and resource efficiency of a partially automated adverse event (AE) surveillance system for routine patient safety efforts in hospitals with limited resources. Twenty-eight automated triggers from the hospital information system's clinical and administrative databases identified cases that were then filtered by exclusion criteria per trigger and then reviewed by an interdisciplinary team. The system, developed and implemented using in-house resources, was applied for 45 days of surveillance, for all hospital inpatient admissions (N = 1107). Each trigger was evaluated for its positive predictive value (PPV). Furthermore, the sensitivity of the surveillance system (overall and by AE category) was estimated relative to incidence ranges in the literature. The surveillance system identified a total of 123 AEs among 283 reviewed medical records, yielding an overall PPV of 52%. The tool showed variable levels of sensitivity across and within AE categories when compared with the literature, with a relatively low overall sensitivity estimated between 21% and 44%. Adverse events were detected in 23 of the 36 AE categories defined by an established harm classification system. Furthermore, none of the detected AEs were voluntarily reported. The surveillance system showed variable sensitivity levels across a broad range of AE categories with an acceptable PPV, overcoming certain limitations associated with other harm detection methods. The number of cases captured was substantial, and none had been previously detected or voluntarily reported. For hospitals with limited resources, this methodology provides valuable safety information from which interventions for quality improvement can be formulated.

  12. Strengthening systems for communicable disease surveillance: creating a laboratory network in Rwanda

    Directory of Open Access Journals (Sweden)

    Ndihokubwayo Jean B

    2011-06-01

    Full Text Available Abstract Background The recent emergence of a novel strain of influenza virus with pandemic potential underscores the need for quality surveillance and laboratory services to contribute to the timely detection and confirmation of public health threats. To provide a framework for strengthening disease surveillance and response capacities in African countries, the World Health Organization Regional Headquarters for Africa (AFRO developed Integrated Disease Surveillance and Response (IDSR aimed at improving national surveillance and laboratory systems. IDSR emphasizes the linkage of information provided by public health laboratories to the selection of relevant, appropriate and effective public health responses to disease outbreaks. Methods We reviewed the development of Rwanda's National Reference Laboratory (NRL to understand essential structures involved in creating a national public health laboratory network. We reviewed documents describing the NRL's organization and record of test results, conducted site visits, and interviewed health staff in the Ministry of Health and in partner agencies. Findings were developed by organizing thematic categories and grouping examples within them. We purposefully sought to identify success factors as well as challenges inherent in developing a national public health laboratory system. Results Among the identified success factors were: a structured governing framework for public health surveillance; political commitment to promote leadership for stronger laboratory capacities in Rwanda; defined roles and responsibilities for each level; coordinated approaches between technical and funding partners; collaboration with external laboratories; and use of performance results in advocacy with national stakeholders. Major challenges involved general infrastructure, human resources, and budgetary constraints. Conclusions Rwanda's experience with collaborative partnerships contributed to creation of a functional

  13. Acoustic array systems theory, implementation, and application

    CERN Document Server

    Bai, Mingsian R; Benesty, Jacob

    2013-01-01

    Presents a unified framework of far-field and near-field array techniques for noise source identification and sound field visualization, from theory to application. Acoustic Array Systems: Theory, Implementation, and Application provides an overview of microphone array technology with applications in noise source identification and sound field visualization. In the comprehensive treatment of microphone arrays, the topics covered include an introduction to the theory, far-field and near-field array signal processing algorithms, practical implementations, and common applic

  14. Emergency Response Data System (ERDS) implementation

    International Nuclear Information System (INIS)

    Jolicoeur, J.

    1990-04-01

    The US Nuclear Regulatory Commission has begun implementation of the Emergency Response Data System (ERDS) to upgrade its ability to acquire data from nuclear power plants in the event of an emergency at the plant. ERDS provides a direct real-time transfer of data from licensee plant computers to the NRC Operations Center. The system has been designed to be activated by the licensee during an emergency which has been classified at an ALERT or higher level. The NRC portion of ERDS will receive the data stream, sort and file the data. The users will include the NRC Operations Center, the NRC Regional Office of the affected plant, and if requested the States which are within the ten mile EPZ of the site. The currently installed Emergency Notification System will be used to supplement ERDS data. This report provides the minimum guidance for implementation of ERDS at licensee sites. It is intended to be used for planning implementation under the current voluntary program as well as for providing the minimum standards for implementing the proposed ERDS rule

  15. Emergency Response Data System (ERDS) implementation

    International Nuclear Information System (INIS)

    Jolicoeur, J.

    1991-06-01

    The US Nuclear Regulatory Commission has begun implementation of the Emergency Response Data System (ERDS) to upgrade its ability to acquire data from nuclear power plants in the event of an emergency at the plant. ERDS provides a direct real-time transfer of data from licensee plant computers to the NRC Operations Center. The system has been designed to be activated by the licensee during an emergency which has been classified at an ALERT or higher level. The NRC portion of ERDS will receive the data stream, sort and file the data. The users will include the NRC Operations Center, the NRC Regional Office of the affected plant, and if requested the States which are within the ten mile EPZ of the site. The currently installed Emergency Notification System will be used to supplement ERDS data. This report provides the minimum guidance for implementation of ERDS at licensee sites. It is intended to be used for planning implementation under the current voluntary program as well as for providing the minimum standards for implementing the proposed ERDS rule. 4 refs., 3 figs

  16. Evaluation of cholera surveillance system in Osu Klottey District, Accra, Ghana (2011-2013).

    Science.gov (United States)

    Adjei, Eric Yirenkyi; Malm, Keziah Laurencia; Mensah, Kofi Nyarko; Sackey, Samuel Oko; Ameme, Donne; Kenu, Ernest; Abdulai, Marijanatu; Mills, Richael; Afari, Edwin

    2017-01-01

    Cholera is an acute illness characterized by profuse watery diarrhea. It is caused by vibrio cholera subgroup 01 and 0139. Rapid administration of fluid replacement therapy and supportive treatment can reduce mortality to around 1%. By the close of 2011, 10,628 cases and 100 deaths were reported in Ghana with a case fatality rate of 0.99. It is important to evaluate the cholera surveillance system in Ghana to determine if it is meeting its objective. The study was conducted in Osu Klottey district in the Accra Metropolitan area in January 2014. We assessed the operations (attributes and performance) of the surveillance system for cholera using CDC guidelines (2001). Surveillance data records at the district level from 2011-2013 were extracted and analyzed for frequency using Microsoft excel. Stakeholders and key informants were interviewed using structured questionnaire. Records were also reviewed at some health facilities and at district levels. In 2011 and 2012, case fatality rates (1.3% and 0.65%) respectively. Males were mostly affected. The most affected age group was 20-29. In 2011, Predictive value positive was 69.2% and 50% in 2012.Cholera peaked in March 2011 and April 2012. The Government of Ghana funded the system. The system is sensitive, simple, stable, flexible, acceptable and representative. It was also useful and data quality was relatively good. Predictive Value Positive was also good. The surveillance system is achieving its set out objectives. The system is sensitive, simple, stable, flexible, and acceptable. Predictive value positive was good.

  17. Surveillance Angels

    NARCIS (Netherlands)

    Rothkrantz, L.J.M.

    2014-01-01

    The use of sensor networks has been proposed for military surveillance and environmental monitoring applications. Those systems are composed of a heterogeneous set of sensors to observe the environment. In centralised systems the observed data will be conveyed to the control room to process the

  18. Implementation of the DIAC control system

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Dae-Sik; Jang, Doh-Yun; Jin, Jeong-Tae; Oh, Byung-Hoon [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    DIAC (Daejeon Ion Accelerator Complex) system was developed, and operated at JAEA of Japan by KEK team with a name of TRIAC (Tokai Radioactive Ion Accelerator Complex) during 2004 to 2010. The TRIAC control system was based on LabView and had two independent control units for ion source and accelerator. To be an efficient system, it is necessary to have an integrated control capability. And the control software, which had implemented by using LabView at TRIAC, will be changed with EPICS in order to give an effective beam service to the users. In this presentation, the old TRIAC control system is described, and a new control system for DIAC is discussed. The control system of DIAC is based on TRIAC. But it is gradually improved performance using EPICS toolkits and changing some digital interface hardware of it. Details of the control system will be demonstrated during the conference.

  19. Reconfigurable Manufacturing System Design and Implementation

    DEFF Research Database (Denmark)

    Hadar, Ronen; Bilberg, Arne

    2013-01-01

    is meant primarily to show the physical feasibility of the system and provide a first-look into a real production application of the RMS ideas. The purpose of this paper is to present the design of the manufacturer’s RMS proof of concept, its implementation, and evaluation results.......Reconfigurable Manufacturing Systems (RMS) have been an increasing area of interest in the research arena. However, it seems that current literature is lacking application and implementation cases where RMS are simulated, tested, and evaluated as a feasible manufacturing concept. A Manufacturer...... of Consumer Goods identified the potential of the RMS concept and decided to investigate the concept in a real production installation. The result of this development is a proof of concept of a changeable and reconfigurable assembly and decoration system based on the principles of RMS. This proof of concept...

  20. Implementation of optimum solar electricity generating system

    International Nuclear Information System (INIS)

    Singh, Balbir Singh Mahinder; Karim, Samsul Ariffin A.; Sivapalan, Subarna; Najib, Nurul Syafiqah Mohd; Menon, Pradeep

    2014-01-01

    Under the 10 th Malaysian Plan, the government is expecting the renewable energy to contribute approximately 5.5% to the total electricity generation by the year 2015, which amounts to 98MW. One of the initiatives to ensure that the target is achievable was to establish the Sustainable Energy Development Authority of Malaysia. SEDA is given the authority to administer and manage the implementation of the feed-in tariff (FiT) mechanism which is mandated under the Renewable Energy Act 2011. The move to establish SEDA is commendable and the FiT seems to be attractive but there is a need to create awareness on the implementation of the solar electricity generating system (SEGS). In Malaysia, harnessing technologies related to solar energy resources have great potential for implementation. However, the main issue that plagues the implementation of SEGS is the intermittent nature of this source of energy. The availability of sunlight is during the day time, and there is a need for electrical energy storage system, so that there is electricity available during the night time as well. The meteorological condition such as clouds, haze and pollution affects the SEGS as well. The PV based SEGS is seems to be promising electricity generating system that can contribute towards achieving the 5.5% target and will be able to minimize the negative effects of utilizing fossil fuels for electricity generation on the environment. Malaysia is committed to Kyoto Protocol, which emphasizes on fighting global warming by achieving stabilization of greenhouse gas concentrations in the atmosphere at a level that would prevent dangerous anthropogenic interference with the climate system. In this paper, the technical aspects of the implementation of optimum SEGS is discussed, especially pertaining to the positioning of the PV panels

  1. Implementation of optimum solar electricity generating system

    Science.gov (United States)

    Singh, Balbir Singh Mahinder; Sivapalan, Subarna; Najib, Nurul Syafiqah Mohd; Menon, Pradeep; Karim, Samsul Ariffin A.

    2014-10-01

    Under the 10th Malaysian Plan, the government is expecting the renewable energy to contribute approximately 5.5% to the total electricity generation by the year 2015, which amounts to 98MW. One of the initiatives to ensure that the target is achievable was to establish the Sustainable Energy Development Authority of Malaysia. SEDA is given the authority to administer and manage the implementation of the feed-in tariff (FiT) mechanism which is mandated under the Renewable Energy Act 2011. The move to establish SEDA is commendable and the FiT seems to be attractive but there is a need to create awareness on the implementation of the solar electricity generating system (SEGS). In Malaysia, harnessing technologies related to solar energy resources have great potential for implementation. However, the main issue that plagues the implementation of SEGS is the intermittent nature of this source of energy. The availability of sunlight is during the day time, and there is a need for electrical energy storage system, so that there is electricity available during the night time as well. The meteorological condition such as clouds, haze and pollution affects the SEGS as well. The PV based SEGS is seems to be promising electricity generating system that can contribute towards achieving the 5.5% target and will be able to minimize the negative effects of utilizing fossil fuels for electricity generation on the environment. Malaysia is committed to Kyoto Protocol, which emphasizes on fighting global warming by achieving stabilization of greenhouse gas concentrations in the atmosphere at a level that would prevent dangerous anthropogenic interference with the climate system. In this paper, the technical aspects of the implementation of optimum SEGS is discussed, especially pertaining to the positioning of the PV panels.

  2. Implementation of optimum solar electricity generating system

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Balbir Singh Mahinder, E-mail: balbir@petronas.com.my; Karim, Samsul Ariffin A., E-mail: samsul-ariffin@petronas.com.my [Department of Fundamental and Applied Sciences, Universiti Teknologi PETRONAS, 31750 Bandar Seri Iskandar, Perak (Malaysia); Sivapalan, Subarna, E-mail: subarna-sivapalan@petronas.com.my [Department of Management and Humanities, Universiti Teknologi PETRONAS, 31750 Bandar Seri Iskandar, Perak (Malaysia); Najib, Nurul Syafiqah Mohd; Menon, Pradeep [Department of Electrical and Electronics Engineering, Universiti Teknologi PETRONAS, 31750 Bandar Seri Iskandar, Perak (Malaysia)

    2014-10-24

    Under the 10{sup th} Malaysian Plan, the government is expecting the renewable energy to contribute approximately 5.5% to the total electricity generation by the year 2015, which amounts to 98MW. One of the initiatives to ensure that the target is achievable was to establish the Sustainable Energy Development Authority of Malaysia. SEDA is given the authority to administer and manage the implementation of the feed-in tariff (FiT) mechanism which is mandated under the Renewable Energy Act 2011. The move to establish SEDA is commendable and the FiT seems to be attractive but there is a need to create awareness on the implementation of the solar electricity generating system (SEGS). In Malaysia, harnessing technologies related to solar energy resources have great potential for implementation. However, the main issue that plagues the implementation of SEGS is the intermittent nature of this source of energy. The availability of sunlight is during the day time, and there is a need for electrical energy storage system, so that there is electricity available during the night time as well. The meteorological condition such as clouds, haze and pollution affects the SEGS as well. The PV based SEGS is seems to be promising electricity generating system that can contribute towards achieving the 5.5% target and will be able to minimize the negative effects of utilizing fossil fuels for electricity generation on the environment. Malaysia is committed to Kyoto Protocol, which emphasizes on fighting global warming by achieving stabilization of greenhouse gas concentrations in the atmosphere at a level that would prevent dangerous anthropogenic interference with the climate system. In this paper, the technical aspects of the implementation of optimum SEGS is discussed, especially pertaining to the positioning of the PV panels.

  3. Expert system for online surveillance of nuclear reactor coolant pumps

    International Nuclear Information System (INIS)

    Gross, K.C.; Singer, R.M.; Humenik, K.E.

    1993-01-01

    An expert system for determining the operability of a specified pump is described comprising: a set of pumps of which the specified pump is a member; means for measuring physical parameters representative to the operations condition each pump of said set of pumps; means for acquiring data generated by said measuring means; an artificial-intelligence based inference engine coupled to said data acquiring means where said inference engine applies a sequential probability ratio test to statistically evaluate said acquired data to determine a status for the specified pump and its respective measuring means by continually monitoring and comparing changes in a specific operational parameter signal acquired from a plurality of measurement means; means for transferring said status generated by said interference engine to an output system

  4. Real-time unmanned aircraft systems surveillance video mosaicking using GPU

    Science.gov (United States)

    Camargo, Aldo; Anderson, Kyle; Wang, Yi; Schultz, Richard R.; Fevig, Ronald A.

    2010-04-01

    Digital video mosaicking from Unmanned Aircraft Systems (UAS) is being used for many military and civilian applications, including surveillance, target recognition, border protection, forest fire monitoring, traffic control on highways, monitoring of transmission lines, among others. Additionally, NASA is using digital video mosaicking to explore the moon and planets such as Mars. In order to compute a "good" mosaic from video captured by a UAS, the algorithm must deal with motion blur, frame-to-frame jitter associated with an imperfectly stabilized platform, perspective changes as the camera tilts in flight, as well as a number of other factors. The most suitable algorithms use SIFT (Scale-Invariant Feature Transform) to detect the features consistent between video frames. Utilizing these features, the next step is to estimate the homography between two consecutives video frames, perform warping to properly register the image data, and finally blend the video frames resulting in a seamless video mosaick. All this processing takes a great deal of resources of resources from the CPU, so it is almost impossible to compute a real time video mosaic on a single processor. Modern graphics processing units (GPUs) offer computational performance that far exceeds current CPU technology, allowing for real-time operation. This paper presents the development of a GPU-accelerated digital video mosaicking implementation and compares it with CPU performance. Our tests are based on two sets of real video captured by a small UAS aircraft; one video comes from Infrared (IR) and Electro-Optical (EO) cameras. Our results show that we can obtain a speed-up of more than 50 times using GPU technology, so real-time operation at a video capture of 30 frames per second is feasible.

  5. TENTACLE Multi-Camera Immersive Surveillance System Phase 2

    Science.gov (United States)

    2015-04-16

    variants available. For a video with 640x480 frame resolution the CPU CIEL*a*b* performs at 11 FPS (Frames Per Second) on a quad core Xeon processor ...running at 2.67 GHz. For the same video the GPU variant of CIEL*a*b* background model processing speed is 44 FPS on the same processor with an Nvidia...The model is also sometimes called HMAX (Hierarchical Model and X). The BIM tries to build a system that emulates object recognition in human cortex

  6. Evaluation of the enterovirus laboratory surveillance system in Denmark, 2010 to 2013

    DEFF Research Database (Denmark)

    Condell, Orla; Midgley, Sofie E; Christiansen, Claus Bohn

    2016-01-01

    The primary aim of the Danish enterovirus (EV) surveillance system is to document absence of poliovirus infection. The conflict in Syria has left many children unvaccinated and movement from areas with polio cases to Europe calls for increased awareness to detect and respond to virus-transmission......The primary aim of the Danish enterovirus (EV) surveillance system is to document absence of poliovirus infection. The conflict in Syria has left many children unvaccinated and movement from areas with polio cases to Europe calls for increased awareness to detect and respond to virus......-transmission in a timely manner. We evaluate the national EV laboratory surveillance, to generate recommendations for system strengthening. The system was analysed for completeness of viral typing analysis and clinical information and timeliness of specimen collection, laboratory results and reporting of clinical...... information. Of 23,720 specimens screened, 2,202 (9.3%) were EV-positive. Submission of cerebrospinal fluid and faecal specimens from primary diagnostic laboratories was 79.5% complete (845/1,063), and varied by laboratory and patient age. EV genotypes were determined in 68.5% (979/1,430) of laboratory...

  7. Privacy as Invisibility: Pervasive Surveillance and the Privatization of Peer-to-Peer Systems

    Directory of Open Access Journals (Sweden)

    Francesca Musiani

    2011-06-01

    Full Text Available This article addresses the ongoing, increasing privatization of peer-to-peer (P2P file sharing systems – the emergence of systems that users may only join by personal, friend-to-friend invitation. It argues that, within P2P systems, privacy is increasingly coinciding with “mere” invisibility vis-à-vis the rest of the Internet ecosystem because of a trend that has shaped the recent history of P2P technology: The alternation between forms of pervasive surveillance of such systems, and reactions by developers and users to such restrictive measures. Yet, it also suggests that the richness of today’s landscape of P2P technology development and use, mainly in the field of Internet-based services, opens up new dimensions to the conceptualization of privacy, and may give room to a more articulate definition of the concept as related to P2P technology; one that includes not only the need of protection from external attacks, and the temporary outcomes of the competition between surveillance and counter-surveillance measures, but also issues such as user empowerment through better control over personal information, reconfiguration of data management practices, and removal of intermediaries in sharing and communication activities.

  8. FPGA Implementation of Heart Rate Monitoring System.

    Science.gov (United States)

    Panigrahy, D; Rakshit, M; Sahu, P K

    2016-03-01

    This paper describes a field programmable gate array (FPGA) implementation of a system that calculates the heart rate from Electrocardiogram (ECG) signal. After heart rate calculation, tachycardia, bradycardia or normal heart rate can easily be detected. ECG is a diagnosis tool routinely used to access the electrical activities and muscular function of the heart. Heart rate is calculated by detecting the R peaks from the ECG signal. To provide a portable and the continuous heart rate monitoring system for patients using ECG, needs a dedicated hardware. FPGA provides easy testability, allows faster implementation and verification option for implementing a new design. We have proposed a five-stage based methodology by using basic VHDL blocks like addition, multiplication and data conversion (real to the fixed point and vice-versa). Our proposed heart rate calculation (R-peak detection) method has been validated, using 48 first channel ECG records of the MIT-BIH arrhythmia database. It shows an accuracy of 99.84%, the sensitivity of 99.94% and the positive predictive value of 99.89%. Our proposed method outperforms other well-known methods in case of pathological ECG signals and successfully implemented in FPGA.

  9. Adverse reactions to cosmetic products and the Notification System in Health Surveillance: a survey.

    Science.gov (United States)

    Huf, Gisele; Rito, Priscila da Nobrega; Presgrave, Rosaura de Farias; Boas, Maria Helena Simoes Villas

    2013-12-01

    This paper is part of a study that investigates the quality of cosmetic products and evaluates the cosmetic surveillance system. This study presents the results of a research that aimed to describe the point of view of the population in terms of the prevalence of Adverse Reactions (AR) and information about the surveillance system. A structured questionnaire was applied to a random sample of 200 people from the administrative staff of the Municipal Guard of Rio de Janeiro. 38% of the participants declared AR to some cosmetic product used in the past two years. To our knowledge, this is an unpublished study in Brazil, which presents results regarding the estimated prevalence of AR similarly to international studies.

  10. Maintenance quality surveillance for nuclear reactor instrument and control systems

    International Nuclear Information System (INIS)

    Clement, T.M.

    1976-01-01

    A description is given of a formal program of mandatory testing and inspection for assurance of reliability at the N-reactor. The techniques and procedures are called Equipment Maintenance Standards (EMS) and cover the nuclear plant systems which affect nuclear safety, environmental control, continuity of operation and reactor life. The scope of the program is such that all electrical, chemical, mechanical, and nuclear devices with interconnecting circuitry, linkages, and piping are functionally checked and/or inspected from sensors through actuating media necessary for carrying out the defined functions under startup, operating, and shutdown conditions and also under any credible accident condition. Records are kept of the AS FOUND results of the tests and inspections along with adjustments and repairs required to correct any out-of-limits conditions found. These records are accumulated and are used as a source for quantitative reliability information and for evaluating wear-out or design problems

  11. Insights from a Systematic Search for Information on Designs, Costs, and Effectiveness of Poliovirus Environmental Surveillance Systems.

    Science.gov (United States)

    Duintjer Tebbens, Radboud J; Zimmermann, Marita; Pallansch, Mark A; Thompson, Kimberly M

    2017-12-01

    Poliovirus surveillance plays a critical role in achieving and certifying eradication and will play a key role in the polio endgame. Environmental surveillance can provide an opportunity to detect circulating polioviruses prior to the observation of any acute flaccid paralysis cases. We completed a systematic review of peer-reviewed publications on environmental surveillance for polio including the search terms "environmental surveillance" or "sewage," and "polio," "poliovirus," or "poliomyelitis," and compared characteristics of the resulting studies. The review included 146 studies representing 101 environmental surveillance activities from 48 countries published between 1975 and 2016. Studies reported taking samples from sewage treatment facilities, surface waters, and various other environmental sources, although they generally did not present sufficient details to thoroughly evaluate the sewage systems and catchment areas. When reported, catchment areas varied from 50 to over 7.3 million people (median of 500,000 for the 25% of activities that reported catchment areas, notably with 60% of the studies not reporting this information and 16% reporting insufficient information to estimate the catchment area population size). While numerous studies reported the ability of environmental surveillance to detect polioviruses in the absence of clinical cases, the review revealed very limited information about the costs and limited information to support quantitative population effectiveness of conducting environmental surveillance. This review motivates future studies to better characterize poliovirus environmental surveillance systems and the potential value of information that they may provide in the polio endgame.

  12. Developing a Formal Specification for the Mission Systems of a Maritime Surveillance Aircraft

    DEFF Research Database (Denmark)

    Petrucci, Laure; Billington, Jonathan; Kristensen, Lars Michael

    2003-01-01

    The mission system of an aircraft is a complex real-time distributed system consisting of a mission control computer, different kinds of devices interconnected by a number of serial data buses. The complexity and real-time requirements of mission systems have motivated research into the applicati...... system with Coloured Petri Nets and analysed the model using state spaces. Here, we describe how this model was refined and modified to obtain a Coloured Petri Net model for the AP-3C Orion maritime surveillance aircraft....

  13. Users manual data base MATSURV. Reactor pressure vessel material surveillance data management system

    International Nuclear Information System (INIS)

    Kenworthy, L.D.; Tether, C.D.

    1980-02-01

    This Users Guide to the data management system MATSURV has been prepared to assist the user in all facets of the task of processing data related to reactor pressure vessel materials surveillance; preparation of raw data for input, input of data, modification of existing data, retrieval and display of data, and the creation of data reports. MATSURV is structured upon the System 2000 data base management system which is maintained on the IBM 370/168 computer at National Institutes of Health. An overview of System 2000 is provided

  14. Development and piloting of the Fiji Injury Surveillance in Hospitals System (TRIP Project-1).

    Science.gov (United States)

    Wainiqolo, I; Kafoa, B; McCaig, E; Kool, B; McIntyre, R; Ameratunga, S

    2013-01-01

    Whilst more than 90% of injury related deaths are estimated to occur in low-and-middle-income countries (LMICs), the epidemiology of fatal and hospitalised injuries in Pacific Island Countries has received scant attention. This study describes the development and piloting of a population-based trauma registry in Fiji to address this gap in knowledge. The Fiji Injury Surveillance in Hospitals (FISH) system was an active surveillance system designed to identify injuries resulting in death or a hospital admission in Viti Levu, Fiji. During the pilot conducted over five months in 2005, Accident and Emergency registers, admission folders and morgue registers from 8 of Viti Levu's 12 hospitals, and an additional 3 hospitals in other parts of the country were reviewed by hospital staff and medical students to identify cases and extract a minimum data set that included demographic factors; the mechanism, nature and context of injury; substance use; and discharge outcomes. The system was audited to identify and redress difficulties with data quality in a manner that also supported local capacity development and training in injury surveillance and data management. This pilot study demonstrated the potential to collect high quality data on injuries that can pose a significant threat to life in Fiji using a mechanism that also increased the capability of health professionals to recognise the significance of injury as a public health issue. The injury surveillance system piloted provides the opportunity to inform national injury control strategies in Fiji and increase the capacity for injury prevention and more focused research addressing risk factors in the local context. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Annual Surveillance Summary: Escherichia coli (E. coli) Infections in the Military Health System (MHS), 2015

    Science.gov (United States)

    2017-03-01

    Annual Surveillance Summary: Escherichia coli ( E . coli ) Infections in the Military Health System (MHS...or position of the Department of the Navy, Department of Defense, nor the U.S. Government. i i E . coli in the MHS: Annual Summary 2015 Prepared...March 2017 EpiData Center Department NMCPHC-EDC-TR-187-2017 ii ii E . coli in the MHS: Annual Summary 2015 Prepared March 2017 EpiData

  16. Recall bias in a case-control surveillance system on the use of medicine during pregnancy

    DEFF Research Database (Denmark)

    Rockenbauer, M.; Olsen, Jørn; Czeizel, A.E.

    2001-01-01

    It is important to study possible teratogenic effects of drugs used during pregnancy. Many studies of this type rely upon case-control designs in which drug intake is recalled by the mothers after having given birth. Recall bias in this situation may lead to spurious associations. We looked...... study. A case-control surveillance system of this type may frequently cause spurious associations, with biased odds ratios up to a factor of 1.9....

  17. Cell Phone-Based System (Chaak) for Surveillance of Immatures of Dengue Virus Mosquito Vectors

    Science.gov (United States)

    LOZANO–FUENTES, SAUL; WEDYAN, FADI; HERNANDEZ–GARCIA, EDGAR; SADHU, DEVADATTA; GHOSH, SUDIPTO; BIEMAN, JAMES M.; TEP-CHEL, DIANA; GARCÍA–REJÓN, JULIÁN E.; EISEN, LARS

    2014-01-01

    Capture of surveillance data on mobile devices and rapid transfer of such data from these devices into an electronic database or data management and decision support systems promote timely data analyses and public health response during disease outbreaks. Mobile data capture is used increasingly for malaria surveillance and holds great promise for surveillance of other neglected tropical diseases. We focused on mosquito-borne dengue, with the primary aims of: 1) developing and field-testing a cell phone-based system (called Chaak) for capture of data relating to the surveillance of the mosquito immature stages, and 2) assessing, in the dengue endemic setting of Mérida, México, the cost-effectiveness of this new technology versus paper-based data collection. Chaak includes a desktop component, where a manager selects premises to be surveyed for mosquito immatures, and a cell phone component, where the surveyor receives the assigned tasks and captures the data. Data collected on the cell phone can be transferred to a central database through different modes of transmission, including near-real time where data are transferred immediately (e.g., over the Internet) or by first storing data on the cell phone for future transmission. Spatial data are handled in a novel, semantically driven, geographic information system. Compared with a pen-and-paper-based method, use of Chaak improved the accuracy and increased the speed of data transcription into an electronic database. The cost-effectiveness of using the Chaak system will depend largely on the up-front cost of purchasing cell phones and the recurring cost of data transfer over a cellular network. PMID:23926788

  18. Overview of the software for the Telemation/Sandia unattended video surveillance system

    International Nuclear Information System (INIS)

    Merillat, P.D.

    1979-10-01

    A microprocessor has been used to provide the major control functions in the Telemation/Sandia unattended video surveillance system. The software in the microprocessor provides control of the various hardware components and provides the capability of interactive communications with the operator. This document, in conjunction with the commented source listing, defines the philosophy and function of the software. It is assumed that the reader is familiar with the RCA 1802 COSMAC microprocessor and has a reasonable computer science background

  19. Comparison of 2 Disability Measures, Behavioral Risk Factor Surveillance System, 2013

    OpenAIRE

    Stevens, Alissa C.; Courtney-Long, Elizabeth A.; Okoro, Catherine A.; Carroll, Dianna D.

    2016-01-01

    Introduction Beginning in 2013, in addition to the 2-item disability question set asked since 2001, Behavioral Risk Factor Surveillance System (BRFSS) began using 5 of the 6 items from the US Department of Health and Human Services?recommended disability question set. We assess and compare disability prevalence using the 2-question and 5-question sets and describe characteristics of respondents who identified as having a disability using each question set. Methods We used data from the 2013 B...

  20. Development and implementation of the quality control panel of RT-PCR and real-time RT-PCR for avian influenza A (H5N1 surveillance network in mainland China

    Directory of Open Access Journals (Sweden)

    Wang Wei

    2011-03-01

    Full Text Available Abstract Background Reverse transcription PCR (RT-PCR and real time RT-PCR (rRT-PCR have been indispensable methods for influenza surveillance, especially for determination of avian influenza. The movement of testing beyond reference lab introduced the need of quality control, including the implementation of an evaluation system for validating personal training and sample proficiency testing. Methods We developed a panel with lysates of seasonal influenza virus (H1N1, H3N2 and B, serials of diluted H5N1 virus lysates, and in-vitro transcribed H5 hemaglutinin (HA and an artificial gene RNAs for RT-PCR and rRT-PCR quality control assessment. The validations of stability and reproducibility were performed on the panel. Additionally, the panel was implemented to assess the detection capability of Chinese human avian influenza networks. Results The panel has relatively high stability and good reproducibility demonstrated by kappa's tests. In the implementation of panel on Chinese human avian influenza networks, the results suggested that there were a relatively low number of discrepancies for both concise and reproducibility in Chinese avian influenza virus net works. Conclusions A quality control panel of RT-PCR and real-time RT-PCR for avian influenza A (H5N1 surveillance network was developed. An availably statistical data, which are used to assess the detection capability of networks on avian influenza virus (H5N1, can be obtained relatively easily through implementation of the panel on networks.

  1. Implementation and Use of Anesthesia Information Management Systems for Non-operating Room Locations.

    Science.gov (United States)

    Bouhenguel, Jason T; Preiss, David A; Urman, Richard D

    2017-12-01

    Non-operating room anesthesia (NORA) encounters comprise a significant fraction of contemporary anesthesia practice. With the implemention of an aneshtesia information management system (AIMS), anesthesia practitioners can better streamline preoperative assessment, intraoperative automated documentation, real-time decision support, and remote surveillance. Despite the large personal and financial commitments involved in adoption and implementation of AIMS and other electronic health records in these settings, the benefits to safety, efficacy, and efficiency are far too great to be ignored. Continued future innovation of AIMS technology only promises to further improve on our NORA experience and improve care quality and safety. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. The quality analysis system implemented by FRAGEMA

    International Nuclear Information System (INIS)

    Kopff, G.

    1988-01-01

    Systematic statistical processing of measurements and quality control data obtained through manufacturing and conformity inspection is necessary for global knowledge of the fuel quality, which is useful both to the designer and to the manufacturer. For this aim the quality control data management and processing system implemented by FRAGEMA is described and illustrated with examples of the different types of statistical quality reports which are printed out. (orig.)

  3. Pervasive surveillance-agent system based on wireless sensor networks: design and deployment

    International Nuclear Information System (INIS)

    Martínez, José F; Bravo, Sury; García, Ana B; Corredor, Iván; Familiar, Miguel S; López, Lourdes; Hernández, Vicente; Da Silva, Antonio

    2010-01-01

    Nowadays, proliferation of embedded systems is enhancing the possibilities of gathering information by using wireless sensor networks (WSNs). Flexibility and ease of installation make these kinds of pervasive networks suitable for security and surveillance environments. Moreover, the risk for humans to be exposed to these functions is minimized when using these networks. In this paper, a virtual perimeter surveillance agent, which has been designed to detect any person crossing an invisible barrier around a marked perimeter and send an alarm notification to the security staff, is presented. This agent works in a state of 'low power consumption' until there is a crossing on the perimeter. In our approach, the 'intelligence' of the agent has been distributed by using mobile nodes in order to discern the cause of the event of presence. This feature contributes to saving both processing resources and power consumption since the required code that detects presence is the only system installed. The research work described in this paper illustrates our experience in the development of a surveillance system using WNSs for a practical application as well as its evaluation in real-world deployments. This mechanism plays an important role in providing confidence in ensuring safety to our environment

  4. Mechatronic Systems Analysis, Design and Implementation

    CERN Document Server

    Boukas, El-Kébir

    2012-01-01

    This book deals with the analysis, the design and the implementation of the mechatronic systems. Classical and modern tools are developed for the analysis and the design for such systems. Robust control, H-Infinity and guaranteed cost control theory are also used for analysis and design of mechatronic systems. Different controller such as state feedback, static output feedback and dynamic output feedback controllers are used to stabilize mechatronic systems. Heuristic algorithms are provided to solve the design of the classical controller such as PID, phase lead, phase lag and phase lead-lag controllers while linear matrix inequalities (LMI) algorithms are provided for finding solutions to the state feedback, static output feedback and dynamic output feedback controllers. The theory presented in the different chapters of the volume is applied to numerical examples to show the usefulness of the theoretical results. Some case studies are also provided to show how the developed concepts apply for real system. Em...

  5. Using Mobile Agents to Implement Workflow System

    Institute of Scientific and Technical Information of China (English)

    LI Jie; LIU Xian-xing; GUO Zheng-wei

    2004-01-01

    Current workflow management systems usually adopt the existing technologies such as TCP/IP-based Web technologies and CORBA as well to fulfill the bottom communications.Very often it has been considered only from a theoretical point of view, mainly for the lack of concrete possibilities to execute with elasticity.MAT (Mobile Agent Technology) represents a very attractive approach to the distributed control of computer networks and a valid alternative to the implementation of strategies for workflow system.This paper mainly focuses on improving the performance of workflow system by using MAT.Firstly, the performances of workflow systems based on both CORBA and mobile agent are summarized and analyzed; Secondly, the performance contrast is presented by introducing the mathematic model of each kind of data interaction process respectively.Last, a mobile agent-based workflow system named MAWMS is presented and described in detail.

  6. ARM Unmanned Aerial Systems Implementation Plan

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, Beat [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Ivey, Mark [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-11-01

    Recent advances in Unmanned Aerial Systems (UAS) coupled with changes in the regulatory environment for operations of UAS in the National Airspace increase the potential value of UAS to the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility. UAS include unmanned aerial vehicles (UAV) and tethered balloon systems (TBS). The roles UAVs and TBSs could play within the ARM Facility, particularly science questions they could help address, have been discussed in several workshops, reports, and vision documents, including: This document describes the implementation of a robust and vigorous program for use of UAV and TBS for the science missions ARM supports.

  7. Evaluation of the national Notifiable Diseases Surveillance System for dengue fever in Taiwan, 2010-2012.

    Directory of Open Access Journals (Sweden)

    Caoimhe McKerr

    2015-03-01

    Full Text Available In Taiwan, around 1,500 cases of dengue fever are reported annually and incidence has been increasing over time. A national web-based Notifiable Diseases Surveillance System (NDSS has been in operation since 1997 to monitor incidence and trends and support case and outbreak management. We present the findings of an evaluation of the NDSS to ascertain the extent to which dengue fever surveillance objectives are being achieved.We extracted the NDSS data on all laboratory-confirmed dengue fever cases reported during 1 January 2010 to 31 December 2012 to assess and describe key system attributes based on the Centers for Disease Control and Prevention surveillance evaluation guidelines. The system's structure and processes were delineated and operational staff interviewed using a semi-structured questionnaire. Crude and age-adjusted incidence rates were calculated and key demographic variables were summarised to describe reporting activity. Data completeness and validity were described across several variables.Of 5,072 laboratory-confirmed dengue fever cases reported during 2010-2012, 4,740 (93% were reported during July to December. The system was judged to be simple due to its minimal reporting steps. Data collected on key variables were correctly formatted and usable in > 90% of cases, demonstrating good data completeness and validity. The information collected was considered relevant by users with high acceptability. Adherence to guidelines for 24-hour reporting was 99%. Of 720 cases (14% recorded as travel-related, 111 (15% had an onset >14 days after return, highlighting the potential for misclassification. Information on hospitalization was missing for 22% of cases. The calculated PVP was 43%.The NDSS for dengue fever surveillance is a robust, well maintained and acceptable system that supports the collection of complete and valid data needed to achieve the surveillance objectives. The simplicity of the system engenders compliance leading to

  8. Surveillance Analysis Computer System (SACS): Software requirements specification (SRS). Revision 2

    International Nuclear Information System (INIS)

    Glasscock, J.A.

    1995-01-01

    This document is the primary document establishing requirements for the Surveillance Analysis Computer System (SACS) database, an Impact Level 3Q system. SACS stores information on tank temperatures, surface levels, and interstitial liquid levels. This information is retrieved by the customer through a PC-based interface and is then available to a number of other software tools. The software requirements specification (SRS) describes the system requirements for the SACS Project, and follows the Standard Engineering Practices (WHC-CM-6-1), Software Practices (WHC-CM-3-10) and Quality Assurance (WHC-CM-4-2, QR 19.0) policies

  9. An Early Warning System Based on Syndromic Surveillance to Detect Potential Health Emergencies among Migrants: Results of a Two-Year Experience in Italy

    Directory of Open Access Journals (Sweden)

    Christian Napoli

    2014-08-01

    Full Text Available Profound geopolitical changes have impacted the southern and eastern Mediterranean since 2010 and defined a context of instability that is still affecting several countries today. Insecurity combined with the reduction of border controls has led to major population movements in the region and to migration surges from affected countries to southern Europe, especially to Italy. To respond to the humanitarian emergency triggered by this migration surge, Italy implemented a syndromic surveillance system in order to rapidly detect potential public health emergencies in immigrant reception centres. This system was discontinued after two years. This paper presents the results of this experience detailing its strengths and weaknesses in order to document the applicability and usefulness of syndromic surveillance in this specific context.

  10. PASSI d'Argento (Silver Steps): the main features of the new nationwide surveillance system for the ageing Italian population, Italy 2013-2014.

    Science.gov (United States)

    Contoli, Benedetta; Carrieri, Patrizia; Masocco, Maria; Penna, Luana; Perra, Alberto

    2016-01-01

    Italy is particularly concerned by population ageing. The costs for society are substantial. In this context a national, representative surveillance system, Passi D'Argento (PDA), was implemented in 2009 to monitor "active aging" and health status in people aged over 64 and to develop preventive health programs to reduce frailty. PDA recruited a representative sample of 24 129 individuals (March 2012-January 2013) aged over 64 who were interviewed by trained staff using a standardized questionnaire. The PDA collects information about participation in society and employment, independent living, health conditions, safety and living environment. Indicator values are used to obtain population health profiles and to compare different LHUs' profiles within the same region or between different regions. The PDA surveillance system proved to be feasible and to be a powerful and innovative local and national tool for monitoring health status, frailty in Italy's elderly population and the essential levels of care currently provided to the elderly.

  11. [Study on smoking-attributed mortality by using all causes of death surveillance system in Tianjin].

    Science.gov (United States)

    Jiang, Guohong; Zhang, Hui; Li, Wei; Wang, Dezheng; Xu, Zhongliang; Song, Guide; Zhang, Ying; Shen, Chengfeng; Zheng, Wenlong; Xue, Xiaodan; Shen, Wenda

    2016-03-01

    To understand the smoking-attributed mortality by inclusion of smoking information into all causes of death surveillance. Since 2010, the information about smoking status, smoking history and the number of cigarettes smoked daily had been added in death surveillance system. The measures of training, supervision, check, sampling survey and telephone verifying were taken to increase death reporting rate and reduce data missing rate and underreporting rate. Multivariate logistic regression analysis was conducted to identify risk factors for smoking-attributed mortality. During the study period (2010-2014), the annual death reporting rates ranged from 6.5‰ to 7.0‰. The reporting rates of smoking status, smoking history and the number of cigarettes smoked daily were 95.53%, 98.63% and 98.58%, respectively. Compared with the nonsmokers, the RR of males was 1.38 (1.33-1.43) for all causes of death and 3.07 (2.91-3.24) for lung cancer due to smoking, the RR of females was 1.46 (1.39-1.54) for all causes of death and 4.07 (3.81-4.35) for lung cancer due to smoking, respectively. The study of smoking attributed mortality can be developed with less investment by using the stable and effective all causes of death surveillance system in Tianjin.

  12. Automated surveillance system for hospital-acquired urinary tract infections in Denmark

    DEFF Research Database (Denmark)

    Condell, Orla; Gubbels, Sophie; Nielsen, J

    2016-01-01

    BACKGROUND: The Danish Hospital-Acquired Infections Database (HAIBA) is an automated surveillance system using hospital administrative, microbiological, and antibiotic medication data. AIM: To define and evaluate the case definition for hospital-acquired urinary tract infection (HA-UTI) and to de......BACKGROUND: The Danish Hospital-Acquired Infections Database (HAIBA) is an automated surveillance system using hospital administrative, microbiological, and antibiotic medication data. AIM: To define and evaluate the case definition for hospital-acquired urinary tract infection (HA-UTI......) and to describe surveillance data from 2010 to 2014. METHODS: The HA-UTI algorithm defined a laboratory-diagnosed UTI as a urine culture positive for no more than two micro-organisms with at least one at ≥10(4)cfu/mL, and a probable UTI as a negative urine culture and a relevant diagnosis code or antibiotic...... treatment. UTI was considered hospital-acquired if a urine sample was collected ≥48h after admission and UTI was calculated per 10,000 risk-days. For validation, prevalence was calculated for each day and compared to point prevalence survey (PPS) data. FINDINGS: HAIBA...

  13. Core state preconception health indicators - pregnancy risk assessment monitoring system and behavioral risk factor surveillance system, 2009.

    Science.gov (United States)

    Robbins, Cheryl L; Zapata, Lauren B; Farr, Sherry L; Kroelinger, Charlan D; Morrow, Brian; Ahluwalia, Indu; D'Angelo, Denise V; Barradas, Danielle; Cox, Shanna; Goodman, David; Williams, Letitia; Grigorescu, Violanda; Barfield, Wanda D

    2014-04-25

    behaviors (e.g., smoking and drinking) among women of reproductive age, and ensuring that chronic conditions are under control. Evidence-based interventions and clinical practice guidelines exist to address these risks and to improve pregnancy outcomes and women's health in general. The results also highlight the need to increase access to health care for all nonpregnant women of reproductive age and the need to encourage the use of essential preventive services for women, including preconception health services. In addition, system changes in community settings can alleviate health problems resulting from inadequate social and emotional support and environments that foster unhealthy lifestyles. Policy changes can promote health equity by encouraging environments that promote healthier options in nutrition and physical activity. Finally, variation in the preconception health status of women by age and race/ethnicity underscores the need for implementing and scaling up proven strategies to reduce persistent health disparities among those at highest risk. Ongoing surveillance and research in preconception health are needed to monitor the influence of improved health-care access and coverage on women's prepregnancy and interpregnancy health status, pregnancy and infant outcomes, and health disparities. Public health decision makers, program planners, researchers, and other key stakeholders can use the state-level PRAMS and BRFSS preconception health indicators to benchmark and monitor preconception health among women of reproductive age. These data also can be used to evaluate the effectiveness of preconception health state and national programs and to assess the need for new programs, program enhancements, and policies.

  14. Cost-effective implementation of intelligent systems

    Science.gov (United States)

    Lum, Henry, Jr.; Heer, Ewald

    1990-01-01

    Significant advances have occurred during the last decade in knowledge-based engineering research and knowledge-based system (KBS) demonstrations and evaluations using integrated intelligent system technologies. Performance and simulation data obtained to date in real-time operational environments suggest that cost-effective utilization of intelligent system technologies can be realized. In this paper the rationale and potential benefits for typical examples of application projects that demonstrate an increase in productivity through the use of intelligent system technologies are discussed. These demonstration projects have provided an insight into additional technology needs and cultural barriers which are currently impeding the transition of the technology into operational environments. Proposed methods which addresses technology evolution and implementation are also discussed.

  15. R and D study on on-line criticality surveillance system (III)

    International Nuclear Information System (INIS)

    Yamada, Sumasu

    1999-02-01

    The Criticality Surveillance System should have high reliability and high expandability enable to apply new approaches. Under this basic concept, a basic design of the Criticality Surveillance System has been proposed in 1997. We propose here several new ideas of modification to the original design of the Criticality Surveillance System, and also reports some results of numerical analysis over the DCA experiments in 1996. In this report, first, we proposed the modification of the Criticality Surveillance System by adding a series of modules for the usage of the Feynman-α method over the γ-ray signal, because recent studies revealed that the statistical analysis of the γ-ray signal in time domain can provide very good information of the reactor decay constant even in the case of low count rate. This modification could increase the reliability of the Criticality Surveillance System over the wide range of amount of the reprocessed fuel in the tank. Last year we have developed an executable ADF program based on the Least Mean Squares, as the redundancy to the recursive ARMA model identification algorithm. However, this algorithm has a property that the convergence rate of parameter estimation becomes very slow when input data is corrupted with colored noise. To cope with this problem, we introduced a new ADF algorithm called Block ADF algorithm, which is developed to improve the convergence rate with less computational load to the computer. In Chapter 2, we showed the basic theory and a fast adaptive filter algorithm using eigenvalue reciprocals as stepsizes in Chapter 3. This new algorithm provides a stable parameter estimates with less computation as fast as the Recursive Least Squares Method. Thirdly, we introduced a notch filter for power line noise and a software. This filter has to be developed for each specific sampling frequency and specific power line frequency, however, this filter can remove not only the line spectrum of the power line frequency but also

  16. Syndromic Surveillance: Enhancing Detection of Disease Outbreaks in Urban China

    NARCIS (Netherlands)

    Pilot, E.; Schwarz, C.; Wang, L.; Krafft, T.; Wang, W.; Krafft, T.; Rosenberg, M.; Pilot, E.

    2014-01-01

    Recently a number of innovative surveillance approaches have been piloted or implemented in several parts of the country. Though Chinese cities have usually a sufficient health infrastructure that is included in the national surveillance system, the differences in treatment seeking behavior of a

  17. Practical experience with a local verification system for containment and surveillance sensors

    International Nuclear Information System (INIS)

    Lauppe, W.D.; Richter, B.; Stein, G.

    1984-01-01

    With the growing number of nuclear facilities and a number of large commercial bulk handling facilities steadily coming into operation the International Atomic Energy Agency is faced with increasing requirements as to reducing its inspection efforts. One means of meeting these requirements will be to deploy facility based remote interrogation methods for its containment and surveillance instrumentation. Such a technical concept of remote interrogation was realized through the so-called LOVER system development, a local verification system for electronic safeguards seal systems. In the present investigations the application was extended to radiation monitoring by introducing an electronic interface between the electronic safeguards seal and the neutron detector electronics of a waste monitoring system. The paper discusses the safeguards motivation and background, the experimental setup of the safeguards system and the performance characteristics of this LOVER system. First conclusions can be drawn from the performance results with respect to the applicability in international safeguards. This comprises in particular the definition of design specifications for an integrated remote interrogation system for various types of containment and surveillance instruments and the specifications of safeguards applications employing such a system

  18. Malaria surveillance and use of evidence in planning and decision ...

    African Journals Online (AJOL)

    Dr. L Mboera

    system on malaria was evaluated using a structured questionnaire and check list. ... Disease surveillance is the ongoing systematic collection, analysis, and ... cases and deaths is critical for the design, implementation and monitoring and ...

  19. Influenza-like illness in a Vietnamese province: epidemiology in correlation with weather factors and determinants from the surveillance system.

    Science.gov (United States)

    Minh An, Dao Thi; Ngoc, Nguyen Thi Bich; Nilsson, Maria

    2014-01-01

    Seasonal influenza affects from 5 to 15% of the world's population annually and causes an estimated 250,000-500,000 deaths worldwide. The World Health Organization (WHO) recommends 'sentinel surveillance' for influenza-like illness (ILI) because it is simple and calls for standardized methods at a relatively low cost that can be implemented throughout the world. In Vietnam, ILI is a key priority for public health also because of its annually recurring temporal pattern. Two major factors, on which the spread of influenza depends, are the strain of the virus and its rate of mutation, since flu strains constantly mutate as they compete with host immune systems. In the context of global climate change, the role of climatic factors has been discussed, as they may significantly contribute to the cause of large outbreaks of ILI. 1) To describe the epidemiology of ILI in Ha Nam province, Vietnam; 2) to seek scientific evidence on the association of ILI occurrence with weather factors in Ha Nam province; and 3) to analyze factors from the Ha Nam ILI surveillance system that contribute to explaining the correlation between the ILI and the weather factors. A data set of 89,270 monthly reported ILI cases from 2008 to 2012 in Ha Nam was used to describe ILI epidemiological characteristics. Spearman correlation analyses between ILI cases and weather factors were conducted to identify which preceding period of months and weather patterns influenced the occurrence of ILI cases. Ten in-depth interviews with health workers in charge of recording and reporting ILI cases at different levels of the ILI surveillance system were conducted to gain a deeper understanding of factors contributing to explaining the relation between the ILI and the weather factors. The results indicated that the ILI occurred annually in all districts of the Ha Nam province in the five studied years. An epidemic occurred in 2009 with the number of cases three times higher than the average threshold. There was a

  20. Containment and surveillance devices

    International Nuclear Information System (INIS)

    Campbell, J.W.; Johnson, C.S.; Stieff, L.R.

    The growing acceptance of containment and surveillance as a means to increase safeguards effectiveness has provided impetus to the development of improved surveillance and containment devices. Five recently developed devices are described. The devices include one photographic and two television surveillance systems and two high security seals that can be verified while installed

  1. An Interfacing System for Radiation Surveillance Using a Radio Communication Network

    International Nuclear Information System (INIS)

    Arunsiri, T.; Punnachaiya, S.; Pattarasumun, A.

    1998-01-01

    The development of an interfacing system for environmental radiation surveillance using radio communication network is aimed to improve a way by which environmental radiation measurement is transmitted and reported from the regional area monitoring station network. This also includes an automatic warning of beacon status via the radio link network to the center of environmental radiation control when an abnormal radiation level is detected. The interfacing system was developed by simulating the EGAT radio link network, the NT 2612, and can be separated into two parts. The first part was for a mobile station which can manage the output data from the radiation measurement system in the standard form of RS-232, IEEE-488, BCD and analog signal. This was accomplished by modulating the signal in selected baud rates ranging from 150 to 9600 bps using an economical radio packet capable of identifying and recalling the station code number. The other part is the linking system between the output data and the microcomputer equipped with a software to manage and evaluate the data from 10 surveillance stations for convenient handing of data output, statistical analysis and transmitting warning signal. Data transmission was tested using a baud rate of 1200 bps and was found to contain no detectable error when digital signal was transmitted while analog signal transmission resulted in deviations of less than ± 0.003%. The development of this radio link system provides a future trend for the environmental radiation monitoring network for countries with nuclear power plants or neighboring countries needed to continuously monitor for any abnormal radiation level in the environment. In case that the radiation surveillance system detects a high level of radiation, a warning signal will be transmitted and appropriate actions may be immediately exercised to control impacts of radiation on environment and living things according to international guidelines

  2. Recent trends in monitoring, control and surveillance systems for capture fisheries

    National Research Council Canada - National Science Library

    Flewwelling, P

    2003-01-01

    ...; review patrol, boarding, inspections and prosecution procedures; and address emerging coatal MCS strategies. Annexes provides further details of operational issues and options for MCS system design and implementation.

  3. Measures and control: which mandatory regulations? which monitoring system to implement? what results to expect? which relations with the administration?; Mesures et controle: quelles obligations reglementaires? quel systeme de surveillance installer? quels resultats en attendre? quels rapports avec l`administration?

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    This workshop is composed of 7 papers on air pollution monitoring and control related to combustion plants and systems: after a presentation of the regulatory framework (at the French and European levels) concerning air pollution and combustion systems, the mechanisms for a clean and efficient combustion are detailed, followed by measures for a quality combustion, pollution emission reduction techniques during combustion, air pollution monitoring and monitors for environment and pollution sources, quality assessment of monitoring systems, automatic monitoring and control of systems and relations with the administration

  4. A method of determining where to target surveillance efforts in heterogeneous epidemiological systems.

    Directory of Open Access Journals (Sweden)

    Alexander J Mastin

    2017-08-01

    Full Text Available The spread of pathogens into new environments poses a considerable threat to human, animal, and plant health, and by extension, human and animal wellbeing, ecosystem function, and agricultural productivity, worldwide. Early detection through effective surveillance is a key strategy to reduce the risk of their establishment. Whilst it is well established that statistical and economic considerations are of vital importance when planning surveillance efforts, it is also important to consider epidemiological characteristics of the pathogen in question-including heterogeneities within the epidemiological system itself. One of the most pronounced realisations of this heterogeneity is seen in the case of vector-borne pathogens, which spread between 'hosts' and 'vectors'-with each group possessing distinct epidemiological characteristics. As a result, an important question when planning surveillance for emerging vector-borne pathogens is where to place sampling resources in order to detect the pathogen as early as possible. We answer this question by developing a statistical function which describes the probability distributions of the prevalences of infection at first detection in both hosts and vectors. We also show how this method can be adapted in order to maximise the probability of early detection of an emerging pathogen within imposed sample size and/or cost constraints, and demonstrate its application using two simple models of vector-borne citrus pathogens. Under the assumption of a linear cost function, we find that sampling costs are generally minimised when either hosts or vectors, but not both, are sampled.

  5. Detecting Ebola with limited laboratory access in the Democratic Republic of Congo: evaluation of a clinical passive surveillance reporting system.

    Science.gov (United States)

    Ashbaugh, Hayley R; Kuang, Brandon; Gadoth, Adva; Alfonso, Vivian H; Mukadi, Patrick; Doshi, Reena H; Hoff, Nicole A; Sinai, Cyrus; Mossoko, Mathias; Kebela, Benoit Ilunga; Muyembe, Jean-Jacques; Wemakoy, Emile Okitolonda; Rimoin, Anne W

    2017-09-01

    Ebola virus disease (EVD) can be clinically severe and highly fatal, making surveillance efforts for early disease detection of paramount importance. In areas with limited access to laboratory testing, the Integrated Disease Surveillance and Response (IDSR) strategy in the Democratic Republic of Congo (DRC) may be a vital tool in improving outbreak response. Using DRC IDSR data from the nation's four EVD outbreak periods from 2007-2014, we assessed trends of Viral Hemorrhagic Fever (VHF) and EVD differential diagnoses reportable through IDSR. With official case counts from active surveillance of EVD outbreaks, we assessed accuracy of reporting through the IDSR passive surveillance system. Although the active and passive surveillance represent distinct sets of data, the two were correlated, suggesting that passive surveillance based only on clinical evaluation may be a useful predictor of true cases prior to laboratory confirmation. There were 438 suspect VHF cases reported through the IDSR system and 416 EVD cases officially recorded across the outbreaks examined. Although collected prior to official active surveillance cases, case reporting through the IDSR during the 2007, 2008 and 2012 outbreaks coincided with official EVD epidemic curves. Additionally, all outbreak areas experienced increases in suspected cases for both malaria and typhoid fever during EVD outbreaks, underscoring the importance of training health care workers in recognising EVD differential diagnoses and the potential for co-morbidities. © 2017 John Wiley & Sons Ltd.

  6. Implementation of Renewable Energy Systems in Denmark

    DEFF Research Database (Denmark)

    Meyer, Niels I

    1997-01-01

    Denmark has been one of the first countries in the world to commit itself to a sustainable energy development. This has been substantiated by two official action plans from 1990 and 1996 with emphasis on energy efficiency and supply systems based on renewable energy. In year 2005, renewable energy...... sources are planned to cover 12-14% and in year 2030 about 35% of total Danish energy demand. This paper reviews the experiences with implementation of renewable energy in Denmark with a focus on wind power and biomass....

  7. Data archiving system implementation in ITER's CODAC Core System

    International Nuclear Information System (INIS)

    Castro, R.; Abadie, L.; Makushok, Y.; Ruiz, M.; Sanz, D.; Vega, J.; Faig, J.; Román-Pérez, G.; Simrock, S.; Makijarvi, P.

    2015-01-01

    Highlights: • Implementation of ITER's data archiving solution. • Integration of the solution into CODAC Core System. • Data archiving structure. • High efficient data transmission into fast plant system controllers. • Fast control and data acquisition in Linux. - Abstract: The aim of this work is to present the implementation of data archiving in ITER's CODAC Core System software. This first approach provides a client side API and server side software allowing the creation of a simplified version of ITERDB data archiving software, and implements all required elements to complete data archiving flow from data acquisition until its persistent storage technology. The client side includes all necessary components that run on devices that acquire or produce data, distributing and streaming to configure remote archiving servers. The server side comprises an archiving service that stores into HDF5 files all received data. The archiving solution aims at storing data coming for the data acquisition system, the conventional control and also processed/simulated data.

  8. Evaluation of the National Human Immunodeficiency Virus Surveillance System for the 2011 diagnosis year.

    Science.gov (United States)

    Karch, Debra L; Chen, Mi; Tang, Tian

    2014-01-01

    In 2009, the Centers for Disease Control and Prevention completed migration of all 59 surveillance project areas (PAs) from the case-based HIV/AIDS Reporting System to the document-based Enhanced HIV/AIDS Reporting System. We conducted a PA-level assessment of Enhanced HIV/AIDS Reporting System process and outcome standards for HIV infection cases. Process standards were reported by PAs and outcome standards were calculated using standardized Centers for Disease Control and Prevention SAS code. A total of 59 PAs including 50 US states, the District of Columbia, 6 separately funded cities (Chicago, Houston, Los Angeles County, New York City, Philadelphia, and San Francisco), and 2 territories (Puerto Rico and the Virgin Islands). Cases diagnosed or reported to the PA surveillance system between January 1, 2011, and December 31, 2011, using data collected through December 2012. Process standards for death ascertainment and intra- and interstate case de-duplication; outcome standards for completeness and timeliness of case reporting, data quality, intrastate duplication rate, risk factor ascertainment, and completeness of initial CD4 and viral load reporting. Fifty-five of 59 PAs (93%) reported linking cases to state vital records death certificates during 2012, 76% to the Social Security Death Master File, and 59% to the National Death Index. Seventy percent completed monthly intrastate, and 63% completed semiannual interstate de-duplication. Eighty-three percent met the 85% or more case ascertainment standard, and 92% met the 66% or more timeliness standard; 75% met the 97% or more data quality standard; all PAs met the 5% or less intrastate duplication rate; 41% met the 85% or more risk factor ascertainment standard; 90% met the 50% or more standard for initial CD4; and 93% met the same standard for viral load reporting. Overall, 7% of PAs met all 11 process and outcome standards. Findings support the need for continued improvement in HIV surveillance activities

  9. EpiScanGIS: an online geographic surveillance system for meningococcal disease

    Directory of Open Access Journals (Sweden)

    Albert Jürgen

    2008-07-01

    Full Text Available Abstract Background Surveillance of infectious diseases increasingly relies on Geographic Information Systems (GIS. The integration of pathogen fine typing data in dynamic systems and visualization of spatio-temporal clusters are a technical challenge for system development. Results An online geographic information system (EpiScanGIS based on open source components has been launched in Germany in May 2006 for real time provision of meningococcal typing data in conjunction with demographic information (age, incidence, population density. Spatio-temporal clusters of disease detected by computer assisted cluster analysis (SaTScan™ are visualized on maps. EpiScanGIS enables dynamic generation of animated maps. The system is based on open source components; its architecture is open for other infectious agents and geographic regions. EpiScanGIS is available at http://www.episcangis.org, and currently has 80 registered users, mostly from the public health service in Germany. At present more than 2,900 cases of invasive meningococcal disease are stored in the database (data as of June 3, 2008. Conclusion EpiScanGIS exemplifies GIS applications and early-warning systems in laboratory surveillance of infectious diseases.

  10. Proposal of a framework for evaluating military surveillance systems for early detection of outbreaks on duty areas

    Directory of Open Access Journals (Sweden)

    Webber Daniel

    2008-04-01

    Full Text Available Abstract Background In recent years a wide variety of epidemiological surveillance systems have been developed to provide early identification of outbreaks of infectious disease. Each system has had its own strengths and weaknesses. In 2002 a Working Group of the Centers for Disease Control and Prevention (CDC produced a framework for evaluation, which proved suitable for many public health surveillance systems. However this did not easily adapt to the military setting, where by necessity a variety of different parameters are assessed, different constraints placed on the systems, and different objectives required. This paper describes a proposed framework for evaluation of military syndromic surveillance systems designed to detect outbreaks of disease on operational deployments. Methods The new framework described in this paper was developed from the cumulative experience of British and French military syndromic surveillance systems. The methods included a general assessment framework (CDC, followed by more specific methods of conducting evaluation. These included Knowledge/Attitude/Practice surveys (KAP surveys, technical audits, ergonomic studies, simulations and multi-national exercises. A variety of military constraints required integration into the evaluation. Examples of these include the variability of geographical conditions in the field, deployment to areas without prior knowledge of naturally-occurring disease patterns, the differences in field sanitation between locations and over the length of deployment, the mobility of military forces, turnover of personnel, continuity of surveillance across different locations, integration with surveillance systems from other nations working alongside each other, compatibility with non-medical information systems, and security. Results A framework for evaluation has been developed that can be used for military surveillance systems in a staged manner consisting of initial, intermediate and final

  11. Health Care Providers' Knowledge and Practice Gap towards Joint Zoonotic Disease Surveillance System: Challenges and Opportunities, Gomma District, Southwest Ethiopia.

    Science.gov (United States)

    Gemeda, Desta Hiko; Sime, Abiot Girma; Hajito, Kifle Woldemichael; Gelalacha, Benti Deresa; Tafese, Wubit; Gebrehiwot, Tsegaye Tewelde

    2016-01-01

    Background. Health care providers play a crucial role for realization of joint zoonotic diseases surveillance by human and animal health sectors, yet there is limited evidence. Hence, this study aimed to determine knowledge and practice gap of health care providers towards the approach for Rabies and Anthrax in Southwest Ethiopia. Methods. A cross-sectional survey was conducted from December 16, 2014, to January 14, 2015. Eligible health care providers were considered for the study. Data were entered in to Epi-data version 3.1 and analyzed using SPSS version 20. Results. A total of 323 (92.02%) health care providers participated in the study. Three hundred sixteen (97.8%) of participants reported that both human and animal health sectors can work together for zoonotic diseases while 96.9% of them replied that both sectors can jointly conduct surveillance. One hundred seventeen (36.2%) of them reported that their respective sectors had conducted joint surveillance for zoonotic diseases. Their involvement was, however, limited to joint outbreak response. Conclusion. There is good opportunity in health care providers' knowledge even though the practice was unacceptably low and did not address all surveillance components. Therefore, formal joint surveillance structure should be in place for optimal implementation of surveillance.

  12. Health Care Providers’ Knowledge and Practice Gap towards Joint Zoonotic Disease Surveillance System: Challenges and Opportunities, Gomma District, Southwest Ethiopia

    Directory of Open Access Journals (Sweden)

    Desta Hiko Gemeda

    2016-01-01

    Full Text Available Background. Health care providers play a crucial role for realization of joint zoonotic diseases surveillance by human and animal health sectors, yet there is limited evidence. Hence, this study aimed to determine knowledge and practice gap of health care providers towards the approach for Rabies and Anthrax in Southwest Ethiopia. Methods. A cross-sectional survey was conducted from December 16, 2014, to January 14, 2015. Eligible health care providers were considered for the study. Data were entered in to Epi-data version 3.1 and analyzed using SPSS version 20. Results. A total of 323 (92.02% health care providers participated in the study. Three hundred sixteen (97.8% of participants reported that both human and animal health sectors can work together for zoonotic diseases while 96.9% of them replied that both sectors can jointly conduct surveillance. One hundred seventeen (36.2% of them reported that their respective sectors had conducted joint surveillance for zoonotic diseases. Their involvement was, however, limited to joint outbreak response. Conclusion. There is good opportunity in health care providers’ knowledge even though the practice was unacceptably low and did not address all surveillance components. Therefore, formal joint surveillance structure should be in place for optimal implementation of surveillance.

  13. PulseNet International: Vision for the implementation of whole genome sequencing (WGS) for global food-borne disease surveillance.

    NARCIS (Netherlands)

    Nadon, Celine; Van Walle, Ivo; Gerner-Smidt, Peter; Campos, Josefina; Chinen, Isabel; Concepcion-Acevedo, Jeniffer; Gilpin, Brent; Smith, Anthony M; Man Kam, Kai; Perez, Enrique; Trees, Eija; Kubota, Kristy; Takkinen, Johanna; Nielsen, Eva Møller; Carleton, Heather

    2017-01-01

    PulseNet International is a global network dedicated to laboratory-based surveillance for food-borne diseases. The network comprises the national and regional laboratory networks of Africa, Asia Pacific, Canada, Europe, Latin America and the Caribbean, the Middle East, and the United States. The

  14. The development of a reliable multi-camera multiplexed CCTV system for safeguards surveillance

    International Nuclear Information System (INIS)

    Gilbert, R.S.; Chiang, K.S.

    1986-01-01

    The background, requirements and system details for a simple reliable Closed Circuit Television (CCTV) system are described. The design of the system presented allows up to 8 CCTV cameras of different makes to be multiplexed and their out-put recorded by three Time Lapse Recorders (TLRs) operating in parallel. This multiplex or MUX-CCTV system is intended to be used by the IAEA for surveillance at several nuclear facilities. The system is unique in that it allows all of the cameras to be operated asynchronously and it provides high quality video during replay. It also incorporates video event counting logic which enables IAEA inspectors to take a very quick inventory of the events which are recorded during unattended operation. This paper discusses other phases of the development for the system and it presents some speculation about future changes which may enhance performance

  15. The temporal relationship between drug supply indicators: an audit of international government surveillance systems

    Science.gov (United States)

    Werb, Dan; Kerr, Thomas; Nosyk, Bohdan; Strathdee, Steffanie; Montaner, Julio; Wood, Evan

    2013-01-01

    Objectives Illegal drug use continues to be a major threat to community health and safety. We used international drug surveillance databases to assess the relationship between multiple long-term estimates of illegal drug price and purity. Design We systematically searched for longitudinal measures of illegal drug supply indicators to assess the long-term impact of enforcement-based supply reduction interventions. Setting Data from identified illegal drug surveillance systems were analysed using an a priori defined protocol in which we sought to present annual estimates beginning in 1990. Data were then subjected to trend analyses. Main outcome measures Data were obtained from government surveillance systems assessing price, purity and/or seizure quantities of illegal drugs; systems with at least 10 years of longitudinal data assessing price, purity/potency or seizures were included. Results We identified seven regional/international metasurveillance systems with longitudinal measures of price or purity/potency that met eligibility criteria. In the USA, the average inflation-adjusted and purity-adjusted prices of heroin, cocaine and cannabis decreased by 81%, 80% and 86%, respectively, between 1990 and 2007, whereas average purity increased by 60%, 11% and 161%, respectively. Similar trends were observed in Europe, where during the same period the average inflation-adjusted price of opiates and cocaine decreased by 74% and 51%, respectively. In Australia, the average inflation-adjusted price of cocaine decreased 14%, while the inflation-adjusted price of heroin and cannabis both decreased 49% between 2000 and 2010. During this time, seizures of these drugs in major production regions and major domestic markets generally increased. Conclusions With few exceptions and despite increasing investments in enforcement-based supply reduction efforts aimed at disrupting global drug supply, illegal drug prices have generally decreased while drug purity has generally

  16. The temporal relationship between drug supply indicators: an audit of international government surveillance systems.

    Science.gov (United States)

    Werb, Dan; Kerr, Thomas; Nosyk, Bohdan; Strathdee, Steffanie; Montaner, Julio; Wood, Evan

    2013-09-30

    Illegal drug use continues to be a major threat to community health and safety. We used international drug surveillance databases to assess the relationship between multiple long-term estimates of illegal drug price and purity. We systematically searched for longitudinal measures of illegal drug supply indicators to assess the long-term impact of enforcement-based supply reduction interventions. Data from identified illegal drug surveillance systems were analysed using an a priori defined protocol in which we sought to present annual estimates beginning in 1990. Data were then subjected to trend analyses. Data were obtained from government surveillance systems assessing price, purity and/or seizure quantities of illegal drugs; systems with at least 10 years of longitudinal data assessing price, purity/potency or seizures were included. We identified seven regional/international metasurveillance systems with longitudinal measures of price or purity/potency that met eligibility criteria. In the USA, the average inflation-adjusted and purity-adjusted prices of heroin, cocaine and cannabis decreased by 81%, 80% and 86%, respectively, between 1990 and 2007, whereas average purity increased by 60%, 11% and 161%, respectively. Similar trends were observed in Europe, where during the same period the average inflation-adjusted price of opiates and cocaine decreased by 74% and 51%, respectively. In Australia, the average inflation-adjusted price of cocaine decreased 14%, while the inflation-adjusted price of heroin and cannabis both decreased 49% between 2000 and 2010. During this time, seizures of these drugs in major production regions and major domestic markets generally increased. With few exceptions and despite increasing investments in enforcement-based supply reduction efforts aimed at disrupting global drug supply, illegal drug prices have generally decreased while drug purity has generally increased since 1990. These findings suggest that expanding efforts at

  17. Development of integrated containment and surveillance system for fast critical facility FCA. Portal and penetration monitors

    International Nuclear Information System (INIS)

    Mukaiyama, Takehiko; Ogawa, Hironobu; Yokota, Yasuhiro.

    1998-01-01

    Manpower and radiation exposure problems, accompanied by frequent Non Destructive Assay (NDA) based inspections at the Fast Critical Facility FCA of Japan Atomic Energy Research Institute (JAERI), are a burden for both the inspectorates and the facility operator. In the hope of alleviating these burdens, the development of containment and surveillance measures for the FCA was initiated in 1979. The integrated containment and surveillance system consists of a portal monitor and a penetration monitor. The reactor building provides an ideal containment measure because of its explosion-proof, airtight structure and limited number of penetrations. The function of the portal monitor is to detect undeclared removal of nuclear material from the reactor building through the doorway. The penetration monitor is designed for surveillance of diversion routes through containment boundaries, and of safeguards related activities for bypassing the portal monitor. The combination of monitoring by the penetration monitor of containment boundaries and all their penetrations except for the doorway, and monitoring by the portal monitor, provides complete coverage of realistic diversion routes. The development of the system was completed in 1988 and the field trial test was conducted for the period of twelve running months. The final report on the field trial was concluded on January 1990. The major conclusion of the report was that the system is effective, reliable and efficient. Following this successful conclusion, the International Atomic Energy Agency (IAEA) accepted the system for meeting its safeguards goals at the FCA on condition that an independent IAEA authentication equipment is provided. The development of the authentication equipment is accomplished as an separate Japan Support Programme for Agency Safeguards (JASPAS) task. (author)

  18. Implementation of a robotic flexible assembly system

    Science.gov (United States)

    Benton, Ronald C.

    1987-01-01

    As part of the Intelligent Task Automation program, a team developed enabling technologies for programmable, sensory controlled manipulation in unstructured environments. These technologies include 2-D/3-D vision sensing and understanding, force sensing and high speed force control, 2.5-D vision alignment and control, and multiple processor architectures. The subsequent design of a flexible, programmable, sensor controlled robotic assembly system for small electromechanical devices is described using these technologies and ongoing implementation and integration efforts. Using vision, the system picks parts dumped randomly in a tray. Using vision and force control, it performs high speed part mating, in-process monitoring/verification of expected results and autonomous recovery from some errors. It is programmed off line with semiautomatic action planning.

  19. Experience and development of on-line BWR surveillance system at Onagawa nuclear power station unit-1

    International Nuclear Information System (INIS)

    Kishi, A.; Chiba, K.; Kato, K.; Ebata, S.; Ando, Y.; Sakamoto, H.

    1986-01-01

    ONAGAWA nuclear power station Unit-1 (Tohoku Electric Power Co.) is a BWR-4 nuclear power station of 524 MW electric power which started commercial operation in June 1984. To attain high reliability and applicability for ONAGAWA-1, Tohoku Electric Power Co. and Toshiba started a Research and Development project on plant surveillance and diagnosis from April 1982. Main purposes of this project are to: (1) Develop an on-line surveillance system and acquire its operating experience at a commercial BWR, (2) Assist in plant operation and maintenance by data acquisition and analysis, (3) Develop a new technique for plant surveillance and diagnosis. An outline of the project, operating experience gained from the on-line surveillance system and an introduction to new diagnosis techniques are reported in this paper. (author)

  20. The EUVAC-NET survey: national pertussis surveillance systems in the European Union, Switzerland, Norway, and Iceland.

    Science.gov (United States)

    Schmidt, J E; Tozzi, A E; Rava, L; Glismann, S

    2001-06-01

    A questionnaire was mailed out to member states of the European Union (EU) plus Switzerland, Norway, and Iceland, to inquire about the type of information routinely recorded in national pertussis surveillance systems. Information was requested on surveillance methods, type of information recorded for cases of pertussis, vaccination schedule, type of vaccine used, and methods for estimating vaccination coverage. Local surveillance methods, vaccination strategies, and methods to estimate vaccination coverage were found to differ widely across the participating countries. The results of the questionnaire survey show, however, that there are comparable subsets of variables common to many countries. Future activities of the EUVAC-NET project will include defining the homogeneous elements in national systems and to group appropriately those countries with common surveillance features.

  1. [Designing and implementation of a web-based quality monitoring system for plasma glucose measurement in multicenter population study].

    Science.gov (United States)

    Liu, Yong; Wang, Limin; Pang, Richard; Mo, Nanxun; Hu, Yan; Deng, Qian; Hu, Zhaohui

    2015-05-01

    The aim of this paper is to describe the designing and implementation of a web-based plasma glucose measurement quality monitoring system to assess the analytical quality of plasma glucose measurements in multicenter population study and provide evidence for the future studies. In the chronic non-communicable disease and related factor surveillance in China, a web based quality monitoring system for plasma glucose measurement was established to conduct evaluation on plasma glucose monitoring quality and effectiveness in 302 surveillance centers, including quality control data entry, transmission and feedback. The majority of the surveillance centers met the quality requirements and passed the evaluation of reproducibility and precision of plasma glucose measurement, only a few centers required intensive training and re-assessment. In order to ensure the completeness and reliability of plasma glucose measurement in the surveillance centers, the establishment of web-based plasma glucose measurement quality control system can facilitate the identification of the qualified surveillance centers and evaluation of plasma glucose measurement quality in different regions. Communication and training are important in ensuring plasma glucose measurement quality. It is necessary to further improve this web-based plasma glucose measurement quality monitoring system in the future to reduce the method specific plasma glucose measurement bias.

  2. A cost-effectiveness analysis of three components of a syndromic surveillance system for the early warning of epidemics in rural China.

    Science.gov (United States)

    Ding, Yan; Sauerborn, Rainer; Xu, Biao; Shaofa, Nie; Yan, Weirong; Diwan, Vinod K; Dong, Hengjin

    2015-11-14

    Syndromic surveillance systems (SSSs) collect non-specific syndromes in early stages of disease outbreaks. This makes an SSS a promising tool for the early detection of epidemics. An Integrated Surveillance System in rural China (ISSC project), which added an SSS to the existing Chinese surveillance system for the early warning of epidemics, was implemented from April 2012 to March 2014 in Jiangxi and Hubei Provinces. This study aims to measure the costs and effectiveness of the three components of the SSS in the ISSC project. The central measures of the cost-effectiveness analysis of the three components of the syndromic surveillance system were: 1) the costs per reported event, respectively, at the health facilities, the primary schools and the pharmacies; and 2) the operating costs per surveillance unit per year, respectively, at the health facilities, the primary schools and the pharmacies. Effectiveness was expressed by reporting outputs which were numbers of reported events, numbers of raw signals, and numbers of verified signals. The reported events were tracked through an internal data base. Signal verification forms and epidemiological investigation reports were collected from local country centers for disease control and prevention. We adopted project managers' perspective for the cost analysis. Total costs included set-up costs (system development and training) and operating costs (data collection, quality control and signal verification). We used self-designed questionnaires to collect cost data and received, respectively, 369 and 477 facility and staff questionnaires through a cross-sectional survey with a purposive sampling following the ISSC project. All data were entered into Epidata 3.02 and exported to Stata for descriptive analysis. The number of daily reported events per unit was the highest at pharmacies, followed by health facilities and finally primary schools. Variances existed within the three groups and also between Jiangxi and Hubei

  3. Quality system implementation for nuclear analytical techniques

    International Nuclear Information System (INIS)

    2004-0