WorldWideScience

Sample records for surveillance radar-1988 doppler

  1. Maritime target and sea clutter measurements with a coherent Doppler polarimetric surveillance radar

    NARCIS (Netherlands)

    Smith, A.J.E.; Gelsema, S.J.; Kester, L.J.H.M.; Melief, H.W.; Premel Cabic, G.; Theil, A.; Woudenberg, E.

    2002-01-01

    Doppler polarimetry in a surveillance radar for the maritime surface picture is considered. This radar must be able to detect low-RCS targets in littoral environments. Measurements on such targets have been conducted with a coherent polarimetric measurement radar in March 2001 and preliminary

  2. Maritime target and sea clutter measurements with a coherent Doppler polarimetric surveillance radar

    NARCIS (Netherlands)

    Smith, A.J.E.; Gelsema, S.J.; Kester, L.J.H.M.; Melief, H.W.; Premel Cabic, G.; Theil, A.; Woudenberg, E.

    2002-01-01

    Doppler polarimetry in a surveillance radar for the maritime surface picture is considered. This radar must be able to detect low-RCS targets in littoral environments. Measurements on such targets have been conducted with a coherent polarimetric measurement radar in March 2001 and preliminary result

  3. A micro-Doppler sonar for acoustic surveillance in sensor networks

    Science.gov (United States)

    Zhang, Zhaonian

    Wireless sensor networks have been employed in a wide variety of applications, despite the limited energy and communication resources at each sensor node. Low power custom VLSI chips implementing passive acoustic sensing algorithms have been successfully integrated into an acoustic surveillance unit and demonstrated for detection and location of sound sources. In this dissertation, I explore active and passive acoustic sensing techniques, signal processing and classification algorithms for detection and classification in a multinodal sensor network environment. I will present the design and characterization of a continuous-wave micro-Doppler sonar to image objects with articulated moving components. As an example application for this system, we use it to image gaits of humans and four-legged animals. I will present the micro-Doppler gait signatures of a walking person, a dog and a horse. I will discuss the resolution and range of this micro-Doppler sonar and use experimental results to support the theoretical analyses. In order to reduce the data rate and make the system amenable to wireless sensor networks, I will present a second micro-Doppler sonar that uses bandpass sampling for data acquisition. Speech recognition algorithms are explored for biometric identifications from one's gait, and I will present and compare the classification performance of the two systems. The acoustic micro-Doppler sonar design and biometric identification results are the first in the field as the previous work used either video camera or microwave technology. I will also review bearing estimation algorithms and present results of applying these algorithms for bearing estimation and tracking of moving vehicles. Another major source of the power consumption at each sensor node is the wireless interface. To address the need of low power communications in a wireless sensor network, I will also discuss the design and implementation of ultra wideband transmitters in a three dimensional

  4. Using a low-order model to detect and characterize intense vortices in multiple-Doppler radar data

    Science.gov (United States)

    Potvin, Corey Keith

    A new multiple-Doppler radar analysis technique is presented for the objective detection and characterization of intense vortices. The technique consists of fitting radial wind data from two or more radars to a simple analytical model of a vortex and its near-environment. The model combines a uniform flow, linear shear flow, linear divergence flow (all of which comprise a broadscale flow), and modified combined Rankine vortex. The vortex and its environment are allowed to translate. A cost-function accounting for the discrepancy between the model and observed radial winds is evaluated over space and time so that observations can be used at the actual times and locations they were acquired. The parameters in the low-order model are determined by minimizing this cost function. The development of the method is initially guided by emulated radial velocity observations of analytical vortices. A high-resolution Advanced Regional Prediction System (ARPS) simulation of a supercellular tornado is then used to generate more realistic pseudo-observations. Finally, the technique is tested using real dual-Doppler tornado and mesocyclone observations from a variety of radar platforms including Weather Surveillance Radar - 1988 Doppler (WSR-88D), Terminal Doppler Weather Radar (TDWR), Shared Mobile Atmospheric Research and Teaching Radar (SMART-R), and Doppler on Wheels (DOW). The technique shows skill in detecting intense vortices and, when the vortex is well-resolved, in retrieving key model parameters including vortex location, translational velocity, radius and maximum tangential wind speed. In cases where the vortex is not well-resolved, additional vortex characteristics computed from the retrieved model parameters and verified against radial velocity observations can still provide useful information about vortex size and strength.

  5. Surveillance

    DEFF Research Database (Denmark)

    Albrechtslund, Anders; Coeckelbergh, Mark; Matzner, Tobias;

    Studying surveillance involves raising questions about the very nature of concepts such as information, technology, identity, space and power. Besides the maybe all too obvious ethical issues often discussed with regard to surveillance, there are several other angles and approaches that we should...... like to encourage. Therefore, our panel will focus on the philosophical, yet non-ethical issues of surveillance in order to stimulate an intense debate with the audience on the ethical implications of our enquiries. We also hope to provide a broader and deeper understanding of surveillance....

  6. Doppler changes as the earliest parameter in fetal surveillance to detect fetal compromise in intrauterine growth-restricted fetuses

    Directory of Open Access Journals (Sweden)

    Bansal Saloni

    2016-01-01

    Full Text Available Introduction. It is estimated that 3-10% of infants are growth restricted. Growth disturbances may have long-term issues. Doppler allows insight into the fetal response to intrauterine stress. Objective. The aim of this study was to detect fetal compromise in intrauterine growth-restricted (IUGR fetuses by means of biophysical profile (BPP vis-а-vis Doppler velocimetry studies of the fetal umbilical artery, and to find out which of the two is a better and earlier predictor of fetal compromise. Methods. A prospective study was conducted on a total of 50 singleton pregnancies with IUGR between 28 and 42 weeks of gestation. Study patients were managed expectantly with nonstress testing and amniotic fluid assessment, BPP and Doppler velocimetry studies of the fetal umbilical artery. Results. Fetal outcome was poor in 5/50 (10% of the fetuses, defined as presence of all of the following: poor Apgar test score, neonatal intensive care unit stay, necrotizing enterocolitis, and low birth weight. Of the four with abnormal BPP, 50% had poor fetal outcomes. Out of 46 with normal BPP, 6.5% had poor fetal outcomes. Conclusion. Inference drawn from the study is that the Doppler technology provides us the opportunity for repetitive noninvasive hemodynamic monitoring in IUGR pregnancies.

  7. Angiogenic factors vs Doppler surveillance in the prediction of adverse outcome among late-pregnancy small-for- gestational-age fetuses.

    Science.gov (United States)

    Lobmaier, S M; Figueras, F; Mercade, I; Perello, M; Peguero, A; Crovetto, F; Ortiz, J U; Crispi, F; Gratacós, E

    2014-05-01

    To compare the value of Doppler surveillance with maternal blood angiogenic factors at diagnosis for the prediction of adverse outcome in late-pregnancy small-for-gestational-age (SGA) fetuses. In a cohort of 198 SGA fetuses we evaluated the association of Doppler indices (mean uterine artery pulsatility index (UtA-PI) and cerebroplacental ratio (CPR)) and angiogenic factors (maternal serum levels of soluble fms-like tyrosine kinase-1 (sFlt-1) and placental growth factor (PlGF)) with the development of pre-eclampsia and adverse perinatal outcome (operative delivery for non-reassuring fetal status or neonatal metabolic acidosis). In SGA fetuses subsequently developing pre-eclampsia, mean UtA-PI (P < 0.001), sFlt-1 MoM (P < 0.001) and sFlt-1/PlGF MoM ratio (P < 0.001) were higher, while PlGF MoM was lower (P = 0.004). In SGA fetuses with adverse perinatal outcome, CPR (P < 0.002) and PlGF MoM (P < 0.001) were lower, and sFlt-1/PlGF MoM ratio was higher (P = 0.001). For predicting pre-eclampsia, the areas under the receiver-operating characteristics (ROC) curves for mean UtA-PI, sFlt-1 MoM and the combination of both were 0.852, 0.839 and 0.860, respectively. For adverse perinatal outcome, the areas under the ROC curves for CPR, PlGF MoM and the combination of both were 0.652, 0.656 and 0.684, respectively. The combination of Doppler indices and angiogenic factors did not significantly improve prediction of either pre-eclampsia (P = 0.851) or adverse outcome (P = 0.579). In SGA fetuses, angiogenic factors at diagnosis and follow-up with Doppler ultrasound both predict adverse outcome with a similar performance. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.

  8. The Doppler Effect--A New Approach

    Science.gov (United States)

    Allen, J.

    1973-01-01

    Discusses the Doppler effect as it applies to different situations, such as a stationary source of sound with the observer moving, a stationary observer, and the sound source and observer both moving. Police radar, satellite surveillance radar, radar astronomy, and the Doppler navigator, are discussed as applications of Doppler shift. (JR)

  9. La surveillance du retard de croissance intra-utérin d'origine vasculaire par la vélocimétrie du Doppler ombilical

    OpenAIRE

    2012-01-01

    Intrauterine growth restriction of vascular origin monitored by umbilical Doppler velocimetry Fetuses with early onset intrauterine growth restriction are at increased risk for adverse short and long term outcomes. The umbilical artery Doppler velocimetry used to monitor fetuses with intrauterine growth restriction (IUGR) allows a reduction in perinatal morbidity and mortality. To monitor fetuses with IUGR, it is recommended to sample a free-floating loop of the umbilical cord as a measuremen...

  10. Doppler Tomography

    CERN Document Server

    Marsh, T R

    2000-01-01

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the a...

  11. Doppler imaging

    Energy Technology Data Exchange (ETDEWEB)

    Piskunov, N [Department of Physics and Astronomy, Uppsala University, Box 515, S-75120 Uppsala (Sweden)], E-mail: piskunov@fysast.uu.se

    2008-12-15

    In this paper, I present a short review of the history and modern status of Doppler imaging techniques, highlighting their dependence on the knowledge of the fundamental stellar parameters, the quality of stellar atmospheric models and the accuracy of spectral synthesis.

  12. The doppler ultrasound. La ecografia Doppler

    Energy Technology Data Exchange (ETDEWEB)

    Contreras Cecilia, E.; Lozano Setien, E.; Hernandez Montero, J.; Ganado Diaz, T.; Jorquera Moya, M.; Blasco Pascual, E. (Hospital Universitario San Carlos. Madrid (Spain))

    1994-01-01

    The discovery and development of Doppler ultrasound has had a great influence on Medical practice since it allows the noninvasive study of vascular pathology, both arterial and venous, as well as the flow patterns of the different parenchyma. This article deals with the principles, limitations and interpretation of the Doppler signal, as well as the different Doppler ultrasound systems routinely employed in Medicine.

  13. Introduction to surveillance studies

    CERN Document Server

    Petersen, JK

    2012-01-01

    Introduction & OverviewIntroduction Brief History of Surveillance Technologies & TechniquesOptical SurveillanceAerial Surveillance Audio Surveillance Radio-Wave SurveillanceGlobal Positioning Systems Sensors Computers & the Internet Data Cards Biochemical Surveillance Animal Surveillance Biometrics Genetics Practical ConsiderationsPrevalence of Surveillance Effectiveness of Surveillance Freedom & Privacy IssuesConstitutional Freedoms Privacy Safeguards & Intrusions ResourcesReferences Glossary Index

  14. Surveillance Pleasures

    DEFF Research Database (Denmark)

    Albrechtslund, Anders

    and leisure have not been studied with the same intensity as e.g. policing, civil liberties and social sorting. This paper offers a study of trends in surveillance pleasures, i.e. watching and eavesdropping in popular culture. My focus is the existential aspects and ethical dilemmas of surveillance...

  15. Differential doppler heterodyning technique

    DEFF Research Database (Denmark)

    Lading, Lars

    1971-01-01

    Measuring velocity without disturbing the moving object is possible by use of the laser doppler heterodyning technique. Theoretical considerations on the doppler shift show that the antenna property of the photodetector can solve an apparent conflict between two different ways of calculating...... the detected doppler frequency. It is found that the doppler frequency for this particular setup is independent of the direction of detection. Investigations of the signal-to-noise ratio (SNR) show that the maximum SNR-considering the optical setup-is obtained by measuring the frequency difference between two...

  16. Tendinopathy and Doppler activity

    DEFF Research Database (Denmark)

    Boesen, M I; Koenig, M J; Torp-Pedersen, S

    2006-01-01

    Intratendinous Doppler activity has been interpreted as an equivalent of neovessels in the Achilles tendon and as a sign of tendinosis (AT).......Intratendinous Doppler activity has been interpreted as an equivalent of neovessels in the Achilles tendon and as a sign of tendinosis (AT)....

  17. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue ...

  18. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been......Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new...

  19. Pulse subtraction Doppler

    Science.gov (United States)

    Mahue, Veronique; Mari, Jean Martial; Eckersley, Robert J.; Caro, Colin G.; Tang, Meng-Xing

    2010-01-01

    Recent advances have demonstrated the feasibility of molecular imaging using targeted microbubbles and ultrasound. One technical challenge is to selectively detect attached bubbles from those freely flowing bubbles and surrounding tissue. Pulse Inversion Doppler is an imaging technique enabling the selective detection of both static and moving ultrasound contrast agents: linear scatterers generate a single band Doppler spectrum, while non-linear scatterers generate a double band spectrum, one being uniquely correlated with the presence of contrast agents and non-linear tissue signals. We demonstrate that similar spectrums, and thus the same discrimination, can be obtained through a Doppler implementation of Pulse Subtraction. This is achieved by reconstructing a virtual echo using the echo generated from a short pulse transmission. Moreover by subtracting from this virtual echo the one generated from a longer pulse transmission, it is possible to fully suppress the echo from linear scatterers, while for non-linear scatterers, a signal will remain, allowing classical agent detection. Simulations of a single moving microbubble and a moving linear scatterer subject to these pulses show that when the virtual echo and the long pulse echo are used to perform pulsed Doppler, the power Doppler spectrum allows separation of linear and non-linear moving scattering. Similar results are obtained on experimental data acquired on a flow containing either microbubble contrast agents or linear blood mimicking fluid. This new Doppler method constitutes an alternative to Pulse Inversion Doppler and preliminary results suggest that similar dual band spectrums could be obtained by the combination of any non-linear detection technique with Doppler demodulation.

  20. Surveillance of Autism.

    Science.gov (United States)

    Boyle, Coleen A.; Bertrand, Jacquelyn; Yeargin-Allsopp, Marshalyn

    1999-01-01

    This article describes the autism surveillance activities of the Center for Disease Control and Prevention. It considers why surveillance to track prevalence of autistic disorders is needed, how such surveillance is conducted, and the special challenges of autism surveillance. (DB)

  1. Surveillance Angels

    NARCIS (Netherlands)

    Rothkrantz, L.J.M.

    2014-01-01

    The use of sensor networks has been proposed for military surveillance and environmental monitoring applications. Those systems are composed of a heterogeneous set of sensors to observe the environment. In centralised systems the observed data will be conveyed to the control room to process the

  2. Surveillance Angels

    NARCIS (Netherlands)

    Rothkrantz, L.J.M.

    2014-01-01

    The use of sensor networks has been proposed for military surveillance and environmental monitoring applications. Those systems are composed of a heterogeneous set of sensors to observe the environment. In centralised systems the observed data will be conveyed to the control room to process the data

  3. Aerial ultrasonic micro Doppler sonar detection range in outdoor environments.

    Science.gov (United States)

    Bradley, Marshall; Sabatier, James M

    2012-03-01

    Current research demonstrates that micro Doppler sonar has the capability to uniquely identify the presence of a moving human, making it an attractive component in surveillance systems for border security applications. Primary environmental factors that limit sonar performance are two-way spreading losses, ultrasonic absorption, and backscattered energy from the ground that appears at zero Doppler shift in the sonar signal processor. Spectral leakage from the backscatter component has a significant effect on sonar performance for slow moving targets. Sonar performance is shown to rapidly decay as the sensor is moved closer to the ground due to increasing surface backscatter levels.

  4. Steerable Doppler transducer probes

    Energy Technology Data Exchange (ETDEWEB)

    Fidel, H.F.; Greenwood, D.L.

    1986-07-22

    An ultrasonic diagnostic probe is described which is capable of performing ultrasonic imaging and Doppler measurement consisting of: a hollow case having an acoustic window which passes ultrasonic energy and including chamber means for containing fluid located within the hollow case and adjacent to a portion of the acoustic window; imaging transducer means, located in the hollow case and outside the fluid chamber means, and oriented to direct ultrasonic energy through the acoustic window toward an area which is to be imaged; Doppler transducer means, located in the hollow case within the fluid chamber means, and movably oriented to direct Doppler signals through the acoustic window toward the imaged area; means located within the fluid chamber means and externally controlled for controllably moving the Doppler transducer means to select one of a plurality of axes in the imaged area along which the Doppler signals are to be directed; and means, located external to the fluid chamber means and responsive to the means for moving, for providing an indication signal for identifying the selected axis.

  5. Air surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Patton, G.W.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the air surveillance and monitoring programs currently in operation at that Hanford Site. Atmospheric releases of pollutants from Hanford to the surrounding region are a potential source of human exposure. For that reason, both radioactive and nonradioactive materials in air are monitored at a number of locations. The influence of Hanford emissions on local radionuclide concentrations was evaluated by comparing concentrations measured at distant locations within the region to concentrations measured at the Site perimeter. This section discusses sample collection, analytical methods, and the results of the Hanford air surveillance program. A complete listing of all analytical results summarized in this section is reported separately by Bisping (1995).

  6. Doppler cooling a microsphere

    CERN Document Server

    Barker, P F

    2010-01-01

    Doppler cooling the center-of-mass motion of an optically levitated microsphere via the velocity dependent scattering force from narrow whispering gallery mode (WGM) resonances is described. Light that is red detuned from the WGM resonance can be used to damp the center-of-mass motion in a process analogous to the Doppler cooling of atoms. Leakage of photons out of the microsphere when the incident field is near resonant with the narrow WGM resonance acts to damp the motion of the sphere. The scattering force is not limited by saturation, but can be controlled by the incident power. Cooling times on the order of seconds are calculated for a 20 micron diameter silica microsphere trapped within optical tweezers, with a Doppler temperature limit in the microKelvin regime.

  7. Pulse Doppler radar

    CERN Document Server

    Alabaster, Clive

    2012-01-01

    This book is a practitioner's guide to all aspects of pulse Doppler radar. It concentrates on airborne military radar systems since they are the most used, most complex, and most interesting of the pulse Doppler radars; however, ground-based and non-military systems are also included. It covers the fundamental science, signal processing, hardware issues, systems design and case studies of typical systems. It will be a useful resource for engineers of all types (hardware, software and systems), academics, post-graduate students, scientists in radar and radar electronic warfare sectors and milit

  8. Doppler radar physiological sensing

    CERN Document Server

    Lubecke, Victor M; Droitcour, Amy D; Park, Byung-Kwon; Singh, Aditya

    2016-01-01

    Presents a comprehensive description of the theory and practical implementation of Doppler radar-based physiological monitoring. This book includes an overview of current physiological monitoring techniques and explains the fundamental technology used in remote non-contact monitoring methods. Basic radio wave propagation and radar principles are introduced along with the fundamentals of physiological motion and measurement. Specific design and implementation considerations for physiological monitoring radar systems are then discussed in detail. The authors address current research and commercial development of Doppler radar based physiological monitoring for healthcare and other applications.

  9. Doppler visibility of coherent random noise radar systems

    Science.gov (United States)

    Li, Zhixi; Narayanan, Ram M.

    2005-05-01

    Random noise radar has recently been used in a variety of imaging and surveillance applications. These systems can be made phase coherent using the technique of heterodyne correlation. Phase coherence has been exploited to measure Doppler and thereby the velocity of moving targets. The Doppler visibility, i.e., the ability to extract Doppler information over the inherent clutter spectra, is constrained by system parameters, especially the phase noise generated by microwave components. Our paper proposes a new phase noise model for the heterodyne mixer as applicable for ultrawideband (UWB) random noise radar and for the local oscillator in the time domain. The Doppler spectra are simulated by including phase noise contamination effects and compared to our previous experimental results. A Genetic Algorithm (GA) optimization routine is applied to synthesize the effects of a variety of parameter combinations to derive a suitable empirical formula for estimating the Doppler visibility in dB. According to the phase noise analysis and the simulation results, the Doppler visibility of UWB random noise radar depends primarily on the following parameters: (a) the local oscillator (LO) drive level of the receiver heterodyne mixer; (b) the saturation current in the receiver heterodyne mixer; (c) the bandwidth of the transmit noise source, and; (d) the target velocity. Other parameters such as the carrier frequency of the receiver LO and the loaded quality factor of the LO have a small effect over the range of applicability of the model and are therefore neglected in the model formulation. The Doppler visibility curves generated from this formula match the simulation results very well over the applicable parameter range within 1 dB. Our model may therefore be used to quickly estimate the Doppler visibility of random noise radars for trade-off analysis.

  10. Scanning laser Doppler vibrometry

    DEFF Research Database (Denmark)

    Brøns, Marie; Thomsen, Jon Juel

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from...

  11. The Doppler Pendulum Experiment

    Science.gov (United States)

    Lee, C. K.; Wong, H. K.

    2011-01-01

    An experiment to verify the Doppler effect of sound waves is described. An ultrasonic source is mounted at the end of a simple pendulum. As the pendulum swings, the rapid change of frequency can be recorded by a stationary receiver using a simple frequency-to-voltage converter. The experimental results are in close agreement with the Doppler…

  12. Surveillance and Critical Theory

    Directory of Open Access Journals (Sweden)

    Christian Fuchs

    2015-09-01

    Full Text Available In this comment, the author reflects on surveillance from a critical theory approach, his involvement in surveillance research and projects, and the status of the study of surveillance. The comment ascertains a lack of critical thinking about surveillance, questions the existence of something called “surveillance studies” as opposed to a critical theory of society, and reflects on issues such as Edward Snowden’s revelations, and Foucault and Marx in the context of surveillance.

  13. Laser Doppler flowmetry imaging

    Science.gov (United States)

    Nilsson, Gert E.; Wardell, Karin

    1994-02-01

    A laser Doppler perfusion imager has been developed that makes possible mapping of tissue blood flow over surfaces with extensions up to about 12 cm X 12 cm. The He-Ne laser beam scans the tissue under study throughout 4096 measurement sites. A fraction of the backscattered and Doppler broadened light is detected by a photo diode positioned about 20 cm above the tissue surface. After processing, a signal that scales linearly with perfusion is stored in a computer and a color coded image of the spatial tissue perfusion is shown on a monitor. A full format scan is completed in about 4.5 minutes. Algorithms for calculating perfusion profiles and averages as well as substraction of one image from another, form an integral part of the system data analysis software. The perfusion images can also be exported to other software packages for further processing and analysis.

  14. Scanning laser Doppler vibrometry

    OpenAIRE

    2016-01-01

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from Polytec Inc. – was acquired and put to operation in October 2014, paid by a sub-donation of DKK 1,5 mill. of the total VILLUM CASMaT grant. Opening possibilities of measuring complicated vibration shapes...

  15. Holographic laser Doppler ophthalmoscopy

    CERN Document Server

    Simonutti, Manuel; Sahel, J A; Gross, Michel; Samson, Benjamin; Magnain, Caroline; Atlan, Michael; 10.1364/OL.35.001941

    2010-01-01

    We report laser Doppler ophthalmoscopic fundus imaging in the rat eye with near-IR heterodyne holography. Sequential sampling of the beat of the reflected radiation against a frequency-shifted optical local oscillator is made onto an array detector. Wide-field maps of fluctuation spectra in the 10 Hz to 25 kHz band exhibit angiographic contrasts in the retinal vascular tree without requirement of an exogenous marker.

  16. Laser double Doppler flowmeter

    Science.gov (United States)

    Poffo, L.; Goujon, J.-M.; Le Page, R.; Lemaitre, J.; Guendouz, M.; Lorrain, N.; Bosc, D.

    2014-05-01

    The Laser Doppler flowmetry (LDF) is a non-invasive method for estimating the tissular blood flow and speed at a microscopic scale (microcirculation). It is used for medical research as well as for the diagnosis of diseases related to circulatory system tissues and organs including the issues of microvascular flow (perfusion). It is based on the Doppler effect, created by the interaction between the laser light and tissues. LDF measures the mean blood flow in a volume formed by the single laser beam, that penetrate into the skin. The size of this measurement volume is crucial and depends on skin absorption, and is not directly reachable. Therefore, current developments of the LDF are focused on the use of always more complex and sophisticated signal processing methods. On the other hand, laser Double Doppler Flowmeter (FL2D) proposes to use two laser beams to generate the measurement volume. This volume would be perfectly stable and localized at the intersection of the two laser beams. With FL2D we will be able to determine the absolute blood flow of a specific artery. One aimed application would be to help clinical physicians in health care units.

  17. Doppler spectral characteristics of infrainguinal vein bypasses

    DEFF Research Database (Denmark)

    Nielsen, Tina G; von Jessen, F; Sillesen, H

    1993-01-01

    With the aim of assessing the velocity profile of femoropopliteal and femorocrural vein bypasses, 128 patients undergoing infrainguinal vein bypass surgery entered a postoperative Duplex surveillance protocol, which included clinical assessment and Duplex scanning, using Doppler spectral analysis...... of arteriovenous fistulas the initially antegrade diastolic velocity was replaced by a retrograde flow within 3 months, whereas a forward flow in diastole was sustained in grafts with patent fistulas. Abnormal Duplex findings in 31 patients led to angiography and revision in 13 cases. Four revised grafts failed......, while nine remained patent at follow-up 1-12 months later. Ten (56%) of 18 non-revised bypasses with abnormal Duplex findings failed within 9 months compared to 1 (1%) of 76 bypasses with a normal velocity profile (p analysis provides...

  18. The surveillant assemblage.

    Science.gov (United States)

    Haggerty, K D; Ericson, R V

    2000-12-01

    George Orwell's 'Big Brother' and Michel Foucault's 'panopticon' have dominated discussion of contemporary developments in surveillance. While such metaphors draw our attention to important attributes of surveillance, they also miss some recent dynamics in its operation. The work of Gilles Deleuze and Felix Guattari is used to analyse the convergence of once discrete surveillance systems. The resultant 'surveillant assemblage' operates by abstracting human bodies from their territorial settings, and separating them into a series of discrete flows. These flows are then reassembled in different locations as discrete and virtual 'data doubles'. The surveillant assemblage transforms the purposes of surveillance and the hierarchies of surveillance, as well as the institution of privacy.

  19. Comparisons between PW Doppler system and enhanced FM Doppler system

    DEFF Research Database (Denmark)

    Wilhjelm, Jens E.; Pedersen, P. C.

    1995-01-01

    This paper presents a new implementation of an echo-ranging FM Doppler system with improved performance, relative to the FM Doppler system reported previously. The use of long sweeps provides a significant reduction in peak to average power ratio compared to pulsed wave (PW) emission. A PW Doppler...... system exploits the direct relationship between arrival time of the received signal and range from the transducer. In the FM Doppler systems, a similar relationship exists in the spectral domain of the demodulated received signals, so that range is represented by frequency. Thus, a shift in location...... of moving scatterers between consecutive emissions corresponds to a frequency shift in the spectral signature. The improvement relative to the earlier version of the FM Doppler system is attained by utilizing cross-correlation of real spectra rather than of magnitude spectra for assessing flow velocity...

  20. ANL Doppler flowmeter

    Science.gov (United States)

    Karplus, H. B.; Raptis, A. C.; Lee, S.; Simpson, T.

    1985-10-01

    A flowmeter has been developed for measuring flow velocity in hot slurries. The flowmeter works on an ultrasonic Doppler principle in which ultrasound is injected into the flowing fluid through the solid pipe wall. Isolating waveguides separate the hot pipe from conventional ultrasonic transducers. Special clamp-on high-temperature transducers also can be adapted to work well in this application. Typical flows in pilot plants were found to be laminar, giving rise to broad-band Doppler spectra. A special circuit based on a servomechanism sensor was devised to determine the frequency average of such a broad spectrum. The device was tested at different pilot plants. Slurries with particulates greater than 70 microns (0.003 in.) yielded good signals, but slurries with extremely fine particulates were unpredictable. Small bubbles can replace the coarse particles to provide a good signal if there are not too many. Successful operation with very fine particulate slurries may have been enhanced by the presence of microbubbles.

  1. Laser Doppler Imaging of Microflow

    CERN Document Server

    Gross, Michel; Leng, Jacques

    2013-01-01

    We report a pilot study with a wide-field laser Doppler detection scheme used to perform laser Doppler anemometry and imaging of particle seeded microflow. The optical field carrying the local scatterers (particles) dynamic state, as a consequence of momentum transfer at each scattering event, is analyzed in the temporal frequencies domain. The setup is based on heterodyne digital holography, which is used to map the scattered field in the object plane at a tunable frequency with a multipixel detector. We show that wide-field heterodyne laser Doppler imaging can be used for quantitative microflow diagnosis; in the presented study, maps of the first-order moment of the Doppler frequency shift are used as a quantitative and directional estimator of the Doppler signature of particles velocity.

  2. Evaluation of multivariate surveillance

    OpenAIRE

    Frisén,Marianne; Andersson, Eva; Schiöler, Linus

    2009-01-01

    Multivariate surveillance is of interest in many areas such as industrial production, bioterrorism detection, spatial surveillance, and financial transaction strategies. Some of the suggested approaches to multivariate surveillance have been multivariate counterparts to the univariate Shewhart, EWMA, and CUSUM methods. Our emphasis is on the special challenges of evaluating multivariate surveillance methods. Some new measures are suggested and the properties of several measures are demonstrat...

  3. Doppler study of middle cerebral artery and umbilical artery in biometrically suspected intra uterine growth restricted pregnancies

    Directory of Open Access Journals (Sweden)

    Rajesh Kuber

    2016-02-01

    Conclusions: Doppler imaging is of value for monitoring pregnancies complicated with IUGR because it can provide indirect evidence of foetal compromise and is known to improve outcome of high risk pregnancies. Doppler evaluation is complementary to all other surveillance modalities. Because the changes in umbilical, uterine and MCA strongly correlate with pregnancy outcome in growth restricted foetuses the use of foetal biometry and Doppler examination is recommended in all cases of suspected IUGR cases. [Int J Res Med Sci 2016; 4(2.000: 403-414

  4. GEIS Surveillance Network Program

    Science.gov (United States)

    2013-10-01

    resistance surveillance, diarrhea etiology and antimicrobial resistance surveillance, sexually transmitted illness surveillance, and capacity building...vomiting, diarrhea , joint pains, general malaise. Of the samples analyzed, only 53.7% had an associated etiology: Malaria (47.0%, EBV (39.7...immunity to the disease. Many adults in those situations are reservoirs, facilitating continuing disease transmission to those without immunity. In Kenya

  5. SOA-surveillance Nederland

    NARCIS (Netherlands)

    Rijlaarsdam J; Bosman A; Laar MJW van de; CIE

    2000-01-01

    In May 1999 a working group was started to evaluate the current surveillance systems for sexually transmitted diseases (STD) and to make suggestions for a renewed effective and efficient STD surveillance system in the Netherlands. The surveillance system has to provide insight into the prevalence an

  6. SOA-surveillance Nederland

    NARCIS (Netherlands)

    Rijlaarsdam J; Bosman A; Laar MJW van de; CIE

    2000-01-01

    In May 1999 a working group was started to evaluate the current surveillance systems for sexually transmitted diseases (STD) and to make suggestions for a renewed effective and efficient STD surveillance system in the Netherlands. The surveillance system has to provide insight into the prevalence

  7. Classification of human activity on water through micro-Dopplers using deep convolutional neural networks

    Science.gov (United States)

    Kim, Youngwook; Moon, Taesup

    2016-05-01

    Detecting humans and classifying their activities on the water has significant applications for surveillance, border patrols, and rescue operations. When humans are illuminated by radar signal, they produce micro-Doppler signatures due to moving limbs. There has been a number of research into recognizing humans on land by their unique micro-Doppler signatures, but there is scant research into detecting humans on water. In this study, we investigate the micro-Doppler signatures of humans on water, including a swimming person, a swimming person pulling a floating object, and a rowing person in a small boat. The measured swimming styles were free stroke, backstroke, and breaststroke. Each activity was observed to have a unique micro-Doppler signature. Human activities were classified based on their micro-Doppler signatures. For the classification, we propose to apply deep convolutional neural networks (DCNN), a powerful deep learning technique. Rather than using conventional supervised learning that relies on handcrafted features, we present an alternative deep learning approach. We apply the DCNN, one of the most successful deep learning algorithms for image recognition, directly to a raw micro-Doppler spectrogram of humans on the water. Without extracting any explicit features from the micro-Dopplers, the DCNN can learn the necessary features and build classification boundaries using the training data. We show that the DCNN can achieve accuracy of more than 87.8% for activity classification using 5- fold cross validation.

  8. Doppler characteristics of sea clutter.

    Energy Technology Data Exchange (ETDEWEB)

    Raynal, Ann Marie; Doerry, Armin Walter

    2010-06-01

    Doppler radars can distinguish targets from clutter if the target's velocity along the radar line of sight is beyond that of the clutter. Some targets of interest may have a Doppler shift similar to that of clutter. The nature of sea clutter is different in the clutter and exo-clutter regions. This behavior requires special consideration regarding where a radar can expect to find sea-clutter returns in Doppler space and what detection algorithms are most appropriate to help mitigate false alarms and increase probability of detection of a target. This paper studies the existing state-of-the-art in the understanding of Doppler characteristics of sea clutter and scattering from the ocean to better understand the design and performance choices of a radar in differentiating targets from clutter under prevailing sea conditions.

  9. Dual-Doppler Feasibility Study

    Science.gov (United States)

    Huddleston, Lisa L.

    2012-01-01

    When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any

  10. Novel instantaneous laser Doppler velocimeter.

    Science.gov (United States)

    Avidor, J M

    1974-02-01

    A laser Doppler velocimeter capable of directly measuring instantaneous velocities is described. The new LDV uses a novel detection technique based on the utilization of a static slightly defocused spherical Fabry-Perot interferometer used in conjunction with a special mask for the detection of instantaneous Doppler frequency shifts. The essential characteristics of this LDV are discussed, and such a system recently developed is described. Results of turbulent flow measurements show good agreement with data obtained using hot wire anemometry.

  11. Sensors for Desert Surveillance

    Directory of Open Access Journals (Sweden)

    B. S. Chauhan

    2005-10-01

    Full Text Available Various types of sensors-visible, passive night vision, infrared, synthetic aperture radar, etc can be used for desert surveillance. The surveillance capability of these sensors depends to a large extent, on various atmospheric effects, viz., absorption, scattering, aerosol, turbulence, and optical mirage. In this paper, effects of various atmospheric phenomena on the transmission of signals, merits and demerits of different means of surveillance under desert environmental conditions are discussed. Advanced surveillance techniques, ie, multisensor fusion, multi and hyperspectral imaging, having special significance for desert surveillance, have also been discussed.

  12. Health environmental risks surveillance systems: toxicological surveillance

    OpenAIRE

    Ana Ferrer Dufol; Santiago Nogué Xarau; Francisco Vargas Marcos; Olivia Castillo Soria; Pilar Gascó Alberich; Ana de la Torre Reoyo; Eduardo de la Peña de Torres

    2004-01-01

    A study of the Clinical Toxicological Section, about the Epidemiological Surveillance in Emergency Services, in relation to chemical products intoxications during the 1999-2003 period, is presented. This work is a result of an agreement between the Spanish Toxicological Association (AETOX) and the Spanish Ministry of Health and Consumption, and was presented in the National Congress of Environment (CONAMA) within the “Health Environmental Risks Surveillance Systems” working group.

  13. Surveillance of fetal arrhythmias in the outpatient setting: current limitations and call for action.

    Science.gov (United States)

    Freire, Grace

    2015-12-01

    Surveillance of fetal arrhythmias in the outpatient setting remains limited by lack of monitoring modalities. Despite technological advances made in the field of obstetrics, existing devices are not currently suitable to monitor fetal arrhythmias. In this report, the author describes the current and developing fetal heart rate monitoring technologies including the recent introduction of hand-held Doppler monitors for outpatient surveillance of fetal arrhythmias.

  14. Reassembling Surveillance Creep

    DEFF Research Database (Denmark)

    Bøge, Ask Risom; Lauritsen, Peter

    2017-01-01

    We live in societies in which surveillance technologies are constantly introduced, are transformed, and spread to new practices for new purposes. How and why does this happen? In other words, why does surveillance “creep”? This question has received little attention either in theoretical...... development or in empirical analyses. Accordingly, this article contributes to this special issue on the usefulness of Actor-Network Theory (ANT) by suggesting that ANT can advance our understanding of ‘surveillance creep’. Based on ANT’s model of translation and a historical study of the Danish DNA database......, we argue that surveillance creep involves reassembling the relations in surveillance networks between heterogeneous actors such as the watchers, the watched, laws, and technologies. Second, surveillance creeps only when these heterogeneous actors are adequately interested and aligned. However...

  15. Planetary Doppler Imaging

    Science.gov (United States)

    Murphy, N.; Jefferies, S.; Hart, M.; Hubbard, W. B.; Showman, A. P.; Hernandez, G.; Rudd, L.

    2014-12-01

    Determining the internal structure of the solar system's gas and ice giant planets is key to understanding their formation and evolution (Hubbard et al., 1999, 2002, Guillot 2005), and in turn the formation and evolution of the solar system. While internal structure can be constrained theoretically, measurements of internal density distributions are needed to uncover the details of the deep interior where significant ambiguities exist. To date the interiors of giant planets have been probed by measuring gravitational moments using spacecraft passing close to, or in orbit around the planet. Gravity measurements are effective in determining structure in the outer envelope of a planet, and also probing dynamics (e.g. the Cassini and Juno missions), but are less effective in probing deep structure or the presence of discrete boundaries. A promising technique for overcoming this limitation is planetary seismology (analogous to helioseismology in the solar case), postulated by Vorontsov, 1976. Using trapped pressure waves to probe giant planet interiors allows insight into the density and temperature distribution (via the sound speed) down to the planetary core, and is also sensitive to sharp boundaries, for example at the molecular to metallic hydrogen transition or at the core-envelope interface. Detecting such boundaries is not only important in understanding the overall structure of the planet, but also has implications for our understanding of the basic properties of matter at extreme pressures. Recent Doppler measurements of Jupiter by Gaulme et al (2011) claimed a promising detection of trapped oscillations, while Hedman and Nicholson (2013) have shown that trapped waves in Saturn cause detectable perturbations in Saturn's C ring. Both these papers have fueled interest in using seismology as a tool for studying the solar system's giant planets. To fully exploit planetary seismology as a tool for understanding giant planet structure, measurements need to be made

  16. General principles of carotid Doppler ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Whal [Dept. of Radiology, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2014-03-15

    Carotid Doppler ultrasonography is a popular tool for evaluating atherosclerosis of the carotid artery. Its two-dimensional gray scale can be used for measuring the intima-media thickness, which is very good biomarker for atherosclerosis and can aid in plaque characterization. The plaque morphology is related to the risk of stroke. The ulceration of plaque is also known as one of the strong predictors of future embolic event risk. Color Doppler ultrasonography and pulse Doppler ultrasonography have been used for detecting carotid artery stenosis. Doppler ultrasonography has unique physical properties. The operator should be familiar with the physics and other parameters of Doppler ultrasonography to perform optimal Doppler ultrasonography studies.

  17. Handbook of surveillance technologies

    CERN Document Server

    Petersen, JK

    2012-01-01

    From officially sanctioned, high-tech operations to budget spy cameras and cell phone video, this updated and expanded edition of a bestselling handbook reflects the rapid and significant growth of the surveillance industry. The Handbook of Surveillance Technologies, Third Edition is the only comprehensive work to chronicle the background and current applications of the full-range of surveillance technologies--offering the latest in surveillance and privacy issues.Cutting-Edge--updates its bestselling predecessor with discussions on social media, GPS circuits in cell phones and PDAs, new GIS s

  18. Redefining syndromic surveillance.

    Science.gov (United States)

    Katz, Rebecca; May, Larissa; Baker, Julia; Test, Elisa

    2011-12-01

    With growing concerns about international spread of disease and expanding use of early disease detection surveillance methods, the field of syndromic surveillance has received increased attention over the last decade. The purpose of this article is to clarify the various meanings that have been assigned to the term syndromic surveillance and to propose a refined categorization of the characteristics of these systems. Existing literature and conference proceedings were examined on syndromic surveillance from 1998 to 2010, focusing on low- and middle-income settings. Based on the 36 unique definitions of syndromic surveillance found in the literature, five commonly accepted principles of syndromic surveillance systems were identified, as well as two fundamental categories: specific and non-specific disease detection. Ultimately, the proposed categorization of syndromic surveillance distinguishes between systems that focus on detecting defined syndromes or outcomes of interest and those that aim to uncover non-specific trends that suggest an outbreak may be occurring. By providing an accurate and comprehensive picture of this field's capabilities, and differentiating among system types, a unified understanding of the syndromic surveillance field can be developed, encouraging the adoption, investment in, and implementation of these systems in settings that need bolstered surveillance capacity, particularly low- and middle-income countries. Copyright © 2011 Ministry of Health, Saudi Arabia. Published by Elsevier Ltd. All rights reserved.

  19. Surveillance of antibiotic resistance

    National Research Council Canada - National Science Library

    Johnson, Alan P

    2015-01-01

    .... Surveillance of antibiotic resistance involves the collection of antibiotic susceptibility test results undertaken by microbiology laboratories on bacteria isolated from clinical samples sent for investigation...

  20. Doppler peaks from active perturbations

    CERN Document Server

    Magueijo, J; Coulson, D; Ferreira, P; Magueijo, Joao; Albrecht, Andreas; Coulson, David; Ferreira, Pedro

    1995-01-01

    We examine how the qualitative structure of the Doppler peaks in the angular power spectrum of the cosmic microwave anisotropy depends on the fundamental nature of the perturbations which produced them. The formalism of Hu and Sugiyama is extended to treat models with cosmic defects. We discuss how perturbations can be ``active'' or ``passive'' and ``incoherent'' or ``coherent'', and show how causality and scale invariance play rather different roles in these various cases. We find that the existence of secondary Doppler peaks and the rough placing of the primary peak unambiguously reflect these basic properties.

  1. Inverse Doppler Effects in Flute

    CERN Document Server

    Zhao, Xiao P; Liu, Song; Shen, Fang L; Li, Lin L; Luo, Chun R

    2015-01-01

    Here we report the observation of the inverse Doppler effects in a flute. It is experimentally verified that, when there is a relative movement between the source and the observer, the inverse Doppler effect could be detected for all seven pitches of a musical scale produced by a flute. Higher tone is associated with a greater shift in frequency. The effect of the inverse frequency shift may provide new insights into why the flute, with its euphonious tone, has been popular for thousands of years in Asia and Europe.

  2. 利用彩色多普勒超声对终末期肾病患者人工动静脉内瘘血管的监测%Using Color Doppler sonography in end-stage renal disease surveillance of artificial blood vessel arteriovenous internal fistula

    Institute of Scientific and Technical Information of China (English)

    顾星; 茅红卫; 季平; 张新源

    2013-01-01

    Objective: The use of Color Doppler sonography monitoring end-stage renal disease artificial vascular arteriove-nous fistula. Methods: 34 cases of Color Doppler sonography in patients with end-stage renal disease artificial arteriovenous fistula vessel diameter, flow velocity, resistance index(RI), blood flow. Results:34 cases of patients with end-stage renal dis-ease in 25 cases of fistula patency good, there are different situations complications in nine cases. Conclusion: Color Doppler sonography in end-stage renal disease artificial arteriovenous fistula of the indicators play an important role in monitoring , artificial arteriovenous fistula inside diameter 3-7 mm, flow rate at 350-800 mL/min can meet the normal amount of hemodialysis.%目的:利用彩色多普勒超声监测终末期肾病患者人工动静脉内瘘的血管。方法:应用彩色多普勒超声测定34例终末期肾病患者人工动静脉内瘘血管内径、血流速度、阻力指数(resistent index,RI)、血流量。结果:34例终末期肾病患者中25例内瘘通畅良好,9例出现不同情况的并发症。结论:彩色多普勒超声在终末期肾病患者人工动静脉内瘘的各项指标监测中起重要作用,人工动静脉内瘘口内径在3~7 mm,血流量在350~800 mL/min时,可满足正常血透量。

  3. Doppler tomography in fusion plasmas and astrophysics

    CERN Document Server

    Salewski, Mirko; Heidbrink, Bill; Jacobsen, Asger Schou; Korsholm, Soren Bang; Leipold, Frank; Madsen, Jens; Moseev, Dmitry; Nielsen, Stefan Kragh; Rasmussen, Jesper; Stagner, Luke; Steeghs, Danny; Stejner, Morten; Tardini, Giovani; Weiland, Markus

    2015-01-01

    Doppler tomography is a well-known method in astrophysics to image the accretion flow, often in the shape of thin discs, in compact binary stars. As accretion discs rotate, all emitted line radiation is Doppler-shifted. In fast-ion D-alpha (FIDA) spectroscopy measurements in magnetically confined plasma, the D-alpha-photons are likewise Doppler-shifted ultimately due to gyration of the fast ions. In either case, spectra of Doppler-shifted line emission are sensitive to the velocity distribution of the emitters. Astrophysical Doppler tomography has lead to images of accretion discs of binaries revealing bright spots, spiral structures, and flow patterns. Fusion plasma Doppler tomography has lead to an image of the fast-ion velocity distribution function in the tokamak ASDEX Upgrade. This image matched numerical simulations very well. Here we discuss achievements of the Doppler tomography approach, its promise and limits, analogies and differences in astrophysical and fusion plasma Doppler tomography, and what ...

  4. Doppler Ultrasound: What Is It Used for?

    Science.gov (United States)

    ... in your neck (carotid artery stenosis) A Doppler ultrasound can estimate how fast blood flows by measuring the rate of change in its pitch (frequency). During a Doppler ultrasound, a technician trained in ultrasound imaging (sonographer) presses ...

  5. Surveillance and persuasion

    NARCIS (Netherlands)

    Nagenborg, Michael

    2014-01-01

    This paper is as much about surveillance as about persuasive technologies (PTs). With regard to PTs it raises the question about the ethical limits of persuasion. It will be argued that even some forms of self-imposed persuasive soft surveillance technologies may be considered unethical. Therefore,

  6. Soil and vegetation surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Antonio, E.J.

    1995-06-01

    Soil sampling and analysis evaluates long-term contamination trends and monitors environmental radionuclide inventories. This section of the 1994 Hanford Site Environmental Report summarizes the soil and vegetation surveillance programs which were conducted during 1994. Vegetation surveillance is conducted offsite to monitor atmospheric deposition of radioactive materials in areas not under cultivation and onsite at locations adjacent to potential sources of radioactivity.

  7. Signal Processing for Radar with Array Antennas and for Radar with Micro-Doppler Measurements

    OpenAIRE

    Björklund, Svante

    2017-01-01

    Radar (RAdio Detection And Ranging) uses radio waves to detect the presence of a target and measure its position and other properties. This sensor has found many civilian and military applications due to advantages such as possible large surveillance areas and operation day and night and in all weather. The contributions of this thesis are within applied signal processing for radar in two somewhat separate research areas: 1) radar with array antennas and 2) radar with micro-Doppler measuremen...

  8. Velocity-aligned Doppler spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Z.; Koplitz, B.; Wittig, C.

    1989-03-01

    The technique of velocity-aligned Doppler spectrosocopy (VADS) is presented and discussed. For photolysis/probe experiments with pulsed initiation, VADS can yield Doppler profiles for nascent photofragments that allow detailed center-of-mass (c.m.) kinetic energy distributions to be extracted. When compared with traditional forms of Doppler spectroscopy, the improvement in kinetic energy resolution is dramatic. Changes in the measured profiles are a consequence of spatial discrimination (i.e., focused and overlapping photolysis and probe beams) and delayed observation. These factors result in the selective detection of species whose velocities are aligned with the wave vector of the probe radiation k/sub pr/, thus revealing the speed distribution along k/sub pr/ rather than the distribution of nascent velocity components projected upon this direction. Mathematical details of the procedure used to model VADS are given, and experimental illustrations for HI, H/sub 2/S, and NH/sub 3/ photodissociation are presented. In these examples, pulsed photodissociation produces H atoms that are detected by sequential two-photon, two-frequency ionization via Lyman-..cap alpha.. with a pulsed laser (121.6+364.7 nm), and measuring the Lyman-..cap alpha.. Doppler profile as a function of probe delay reveals both internal and c.m. kinetic energy distributions for the photofragments. Strengths and weaknesses of VADS as a tool for investigating photofragmentation phenomena are also discussed.

  9. Speckles in laser doppler perfusion imaging

    NARCIS (Netherlands)

    Rajan, Vinayakrishnan

    2007-01-01

    Laser Doppler Flowmetry (LDF) is a noninvasive diagnostic method to measure blood flow in tissue [1]. The technique is based on measuring the Doppler shift induced by moving red blood cells to the illuminating coherent light. A laser Doppler instrument often gives output signals related to the flux,

  10. Micro-Doppler Analysis of Small UAVs

    NARCIS (Netherlands)

    Wit, J.J.M. de; Harmanny, R.I.A.; Prémel Cabic, G.

    2012-01-01

    Coherent radar measures micro-Doppler properties of moving objects. The micro-Doppler signature depends on parts of an object moving and rotating in addition to the main body motion (e.g. rotor blades) and is therefore characteristic for the type of object. In this study, the micro-Doppler signature

  11. Micro-Doppler Analysis of Small UAVs

    NARCIS (Netherlands)

    Wit, J.J.M. de; Harmanny, R.I.A.; Prémel Cabic, G.

    2012-01-01

    Coherent radar measures micro-Doppler properties of moving objects. The micro-Doppler signature depends on parts of an object moving and rotating in addition to the main body motion (e.g. rotor blades) and is therefore characteristic for the type of object. In this study, the micro-Doppler signature

  12. 2012 Sexually Transmitted Diseases Surveillance

    Science.gov (United States)

    ... National Summary Chlamydia Gonorrhea Syphilis Chancroid Selected STDs Appendix Appendix Interpreting STD Surveillance Data Appendix Tables A1 - A4 STD Surveillance Case Definitions Contributors ...

  13. Doppler indicates of uterine artery Doppler velocimetry by placental location

    Energy Technology Data Exchange (ETDEWEB)

    Han, Sung Shik; Park, Yong Won; Cho, Jae Sung; Kwon, Hye Kyeung; Kim, Jae Wook [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2001-09-15

    Our purpose was to investigate the relation between the vascular resistance of uterine artery and placental location and to establish the reference value of Doppler index in uterine artery by placental location. Placental location and flow velocity waveforms of both uterine arteries in 7,016 pregnant women after 18 weeks gestation were examined using color Doppler ultrasonography. Placental location was classified as central and lateral placental and the uterine artery with lateral placental were divided into ipsilateral uterine artery (same side of the placental) and contralateral uterine artery (opposite side of the placenta). The uterine artery with central placental was classified as the central uterine artery. Systolic-Diastolic ratio (S/D ratio) of uterine arteries by gestational weeks were calculated and compared with the placental location and perinatal outcomes. In the lateral placental group, the S/D ratio of the contralateral uterine artery was higher than the ipsilateral one (mean=2.08+0.34 vs 1.89+0.34, p=0.0001). S/D ratio of the uterine artery decreased during second trimester and the ratio after 27 weeks was a tendency to have a constant values(ipsilateral: 1.85+ 0.34, central : 1.96+ 0.40, contralateral: 2.01+0.54). S/D ratio of the uterine artery was affected by placental location. So when we evaluate Doppler spectrum of uterine artery, placental location should be considered and we established the reference value of Doppler index of uterine artery by placental location.

  14. Azimuthal Doppler Effect in Optical Vortex Spectroscopy

    Science.gov (United States)

    Aramaki, Mitsutoshi; Yoshimura, Shinji; Toda, Yasunori; Morisaki, Tomohiro; Terasaka, Kenichiro; Tanaka, Masayoshi

    2015-11-01

    Optical vortices (OV) are a set of solutions of the paraxial Helmholtz equation in the cylindrical coordinates, and its wave front has a spiral shape. Since the Doppler shift is caused by the phase change by the movement in a wave field, the observer in the OV, which has the three-dimensional structured wave front, feels a three-dimensional Doppler effect. Since the multi-dimensional Doppler components are mixed into a single Doppler spectrum, development of a decomposition method is required. We performed a modified saturated absorption spectroscopy to separate the components. The OV and plane wave are used as a probe beam and pump beam, respectively. Although the plane-wave pump laser cancels the z-direction Doppler shift, the azimuthal Doppler shift remains in the saturated dip. The spatial variation of the dip width gives the information of the azimuthal Doppler shift. The some results of optical vortex spectroscopy will be presented.

  15. Velocity-aligned Doppler spectroscopy

    Science.gov (United States)

    Xu, Z.; Koplitz, B.; Wittig, C.

    1989-03-01

    The use of velocity-aligned Doppler spectroscopy (VADS) to measure center-of-mass kinetic-energy distributions of nascent photofragments produced in pulsed-initiation photolysis/probe experiments is described and demonstrated. In VADS, pulsed photolysis and probe laser beams counterpropagate through the ionization region of a time-of-flight mass spectrometer. The theoretical principles of VADS and the mathematical interpretation of VADS data are explained and illustrated with diagrams; the experimental setup is described; and results for the photodissociation of HI, H2S, and NH3 are presented in graphs and characterized in detail. VADS is shown to give much higher kinetic-energy resolution than conventional Doppler spectroscopy.

  16. Children's Mental Health Surveillance

    Science.gov (United States)

    Children’s Mental Health Surveillance What are childhood mental disorders? The term childhood mental disorder means all mental disorders that can ... is the impact of mental disorders in children? Mental health is important to overall health. Mental disorders are ...

  17. Between visibility and surveillance

    DEFF Research Database (Denmark)

    Uldam, Julie

    visible. It thus enables activists to monitor and expose corporate misconduct, but simultaneously renders them vulnerable to surveillance from corporations. In this presentation, I examine these practices and discuss their implications for political participation by drawing on examples of companies...

  18. Autonomous surveillance for biosecurity.

    Science.gov (United States)

    Jurdak, Raja; Elfes, Alberto; Kusy, Branislav; Tews, Ashley; Hu, Wen; Hernandez, Emili; Kottege, Navinda; Sikka, Pavan

    2015-04-01

    The global movement of people and goods has increased the risk of biosecurity threats and their potential to incur large economic, social, and environmental costs. Conventional manual biosecurity surveillance methods are limited by their scalability in space and time. This article focuses on autonomous surveillance systems, comprising sensor networks, robots, and intelligent algorithms, and their applicability to biosecurity threats. We discuss the spatial and temporal attributes of autonomous surveillance technologies and map them to three broad categories of biosecurity threat: (i) vector-borne diseases; (ii) plant pests; and (iii) aquatic pests. Our discussion reveals a broad range of opportunities to serve biosecurity needs through autonomous surveillance. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  19. 522 Postmarket Surveillance Studies

    Data.gov (United States)

    U.S. Department of Health & Human Services — The 522 Postmarket Surveillance Studies Program encompasses design, tracking, oversight, and review responsibilities for studies mandated under section 522 of the...

  20. 522 Postmarket Surveillance Studies

    Data.gov (United States)

    U.S. Department of Health & Human Services — The 522 Postmarket Surveillance Studies Program encompasses design, tracking, oversight, and review responsibilities for studies mandated under section 522 of the...

  1. Aortic isthmus Doppler velocimetry: role in assessment of preterm fetal growth restriction.

    LENUS (Irish Health Repository)

    Kennelly, M M

    2012-02-01

    Intrauterine fetal growth restriction (IUGR) is an important pregnancy complication associated with significant adverse clinical outcome, stillbirth, perinatal morbidity and cerebral palsy. To date, no uniformly accepted management protocol of Doppler surveillance that reduces mortality and cognitive morbidity has emerged. Aortic isthmus (AoI) evaluation has been proposed as a potential monitoring tool for IUGR fetuses. In this review, the current knowledge of the relationship between AoI Doppler velocimetry and preterm fetal growth restriction is reviewed. Relevant technical aspects and reproducibility data are reviewed as we discuss AoI Doppler and its place within the existing repertoire of Doppler assessments in placental insufficiency. The AoI is a link between the right and left ventricles which perfuse the lower and upper body, respectively. The clinical use of AoI waveforms for monitoring fetal deterioration in IUGR has been limited, but preliminary work suggests that abnormal AoI impedance indices are an intermediate step between placental insufficiency-hypoxemia and cardiac decompensation. Further prospective studies correlating AoI indices with arterial and venous Doppler indices and perinatal outcome are required before encorporating this index into clinical practice.

  2. Range ambiguity resolution for high PRF pulse-Doppler radar

    Science.gov (United States)

    Postema, G. B.

    The range ambiguity resolution for high 'PRF pulse-Doppler radars can be resolved using a simple algorithm based on residue arithmetic. The unambiguous range is found from R = T + R(a), where T is the output of a look-up table and R(a) is one of the measured ambiguous ranges. This formula is easily extended to multiple PRF ranging systems, where three or more measurements are required for the ambiguity resolution. Target obscuration in clutter reduces the visibility and leads, especially in dense target environments, to ghost ranges. It is shown that long range coverage requires a small resolved pulse length and PRFs as low as practical in the intended clutter and target environment. Special attention is given to the generation of sparsely populated look-up tables that reduce the ghosting problem. A practical example for an S-band surveillance radar is presented.

  3. DOPPLER ANALYSIS IN PREGNANCY INDUCED HYPERTENSION

    Directory of Open Access Journals (Sweden)

    Tushar

    2014-12-01

    Full Text Available A study of 50 cases was conducted to evaluate the role of Colour Doppler imaging in pregnancy induced hypertension with women over 28 weeks of gestation, the initial scan was performed immediately after the diagnosis of PIH to avoid any influence of treatment on Doppler evaluation. This study was aimed to analyze the blood flow in umbilical artery, maternal uterine artery & fetal middle cerebral artery using Doppler ultrasound.

  4. Surveillance Metrics Sensitivity Study

    Energy Technology Data Exchange (ETDEWEB)

    Bierbaum, R; Hamada, M; Robertson, A

    2011-11-01

    In September of 2009, a Tri-Lab team was formed to develop a set of metrics relating to the NNSA nuclear weapon surveillance program. The purpose of the metrics was to develop a more quantitative and/or qualitative metric(s) describing the results of realized or non-realized surveillance activities on our confidence in reporting reliability and assessing the stockpile. As a part of this effort, a statistical sub-team investigated various techniques and developed a complementary set of statistical metrics that could serve as a foundation for characterizing aspects of meeting the surveillance program objectives. The metrics are a combination of tolerance limit calculations and power calculations, intending to answer level-of-confidence type questions with respect to the ability to detect certain undesirable behaviors (catastrophic defects, margin insufficiency defects, and deviations from a model). Note that the metrics are not intended to gauge product performance but instead the adequacy of surveillance. This report gives a short description of four metrics types that were explored and the results of a sensitivity study conducted to investigate their behavior for various inputs. The results of the sensitivity study can be used to set the risk parameters that specify the level of stockpile problem that the surveillance program should be addressing.

  5. Emboli detection using the Doppler ultrasound technique

    Institute of Scientific and Technical Information of China (English)

    WANG Yuanyuan; CHEN Xi; ZHANG Yu; WANG Weiqi

    2003-01-01

    Embolic detection is very important to the early diagnosis of vessel disease. The Doppler ultrasound technique is one of the common methods to detect the emboli non-invasively. When the emboli pass through the sample volume of the Doppler ultrasound instrument, there exist high intensity transient Doppler signals. Thus the emboli can be detected directly from the variation of Doppler signal amplitude. Since there may be some disturbance in the system, this general detection method has great limitation. To improve the accuracy of emboli auto-detection, several novel methods are studied to obtain the sensitive characteristic of the emboli signals using the new signal processing theories.

  6. Internet and Surveillance

    DEFF Research Database (Denmark)

    The Internet has been transformed in the past years from a system primarily oriented on information provision into a medium for communication and community-building. The notion of “Web 2.0”, social software, and social networking sites such as Facebook, Twitter and MySpace have emerged...... institutions have a growing interest in accessing this personal data. Here, contributors explore this changing landscape by addressing topics such as commercial data collection by advertising, consumer sites and interactive media; self-disclosure in the social web; surveillance of file-sharers; privacy...... in the age of the internet; civil watch-surveillance on social networking sites; and networked interactive surveillance in transnational space. This book is a result of a research action launched by the intergovernmental network COST (European Cooperation in Science and Technology)....

  7. The plays and arts of surveillance: studying surveillance as entertainment

    NARCIS (Netherlands)

    Albrechtslund, Anders; Dubbeld, L.

    2006-01-01

    This paper suggests a direction in the development of Surveillance Studies that goes beyond current attention for the caring, productive and enabling aspects of surveillance practices. That is, surveillance could be considered not just as positively protective, but even as a comical, playful,

  8. Doppler tomography in fusion plasmas and astrophysics

    DEFF Research Database (Denmark)

    Salewski, Mirko; Geiger, B.; Heidbrink, W. W.

    2015-01-01

    Doppler tomography is a well-known method in astrophysics to image the accretion flow, often in the shape of thin discs, in compact binary stars. As accretion discs rotate, all emitted line radiation is Doppler-shifted. In fast-ion Dα (FIDA) spectroscopy measurements in magnetically confined plas...

  9. Radar Doppler Processing with Nonuniform Sampling.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Conventional signal processing to estimate radar Doppler frequency often assumes uniform pulse/sample spacing. This is for the convenience of t he processing. More recent performance enhancements in processor capability allow optimally processing nonuniform pulse/sample spacing, thereby overcoming some of the baggage that attends uniform sampling, such as Doppler ambiguity and SNR losses due to sidelobe control measures.

  10. Doppler tomography in fusion plasmas and astrophysics

    NARCIS (Netherlands)

    Salewski, M.; Geiger, B.; Heidbrink, W. W.; Jacobsen, A. S.; Korsholm, S. B.; Leipold, F.; Madsen, J.; Moseev, D.; Nielsen, S.K.; Rasmussen, J.; Stagner, L.; Steeghs, D.; Stejner, M.; Tardini, G.; Weiland, M.; ASDEX Upgrade team,

    2015-01-01

    Doppler tomography is a well-known method in astrophysics to image the accretion flow, often in the shape of thin discs, in compact binary stars. As accretion discs rotate, all emitted line radiation is Doppler-shifted. In fast-ion D-alpha (FIDA) spectroscopy measurements in magnetically confined pl

  11. Diagnostics and surveillance methods

    Science.gov (United States)

    Detection and diagnosis of influenza A virus (IAV) infection in animals requires a laboratory test since disease from IAV presents no pathognomonic signs. Diagnosis and surveillance of animal influenza focuses on the detection of virus or type specific antibodies. Whether one targets the virus or ...

  12. Active surveillance: Oncologic outcome

    NARCIS (Netherlands)

    L.D.F. Venderbos (Lionne); L.P. Bokhorst (Leonard); C.H. Bangma (Chris); M.J. Roobol-Bouts (Monique)

    2013-01-01

    textabstractPURPOSE OF REVIEW: To give insight into recent literature (during the past 12-18 months) reporting on oncologic outcomes of men on active surveillance. RECENT FINDINGS: From recent published trials comparing radical prostatectomy vs. watchful waiting, we learn that radical treatment only

  13. Pregnancy nutrition surveillance system.

    Science.gov (United States)

    2003-01-01

    The Pregnancy Nutrition Surveillance System is a useful tool in monitoring Healthy People 2010 objectives and is intended to provide a framework for analyzing data on the nutritional status and behavioral risk factors of pregnant women and the association to birth outcome. The data are useful to health professionals in providing prenatal care and developing programs to reduce pregnancy-related health risks.

  14. Inverse Doppler Effects in Broadband Acoustic Metamaterials.

    Science.gov (United States)

    Zhai, S L; Zhao, X P; Liu, S; Shen, F L; Li, L L; Luo, C R

    2016-08-31

    The Doppler effect refers to the change in frequency of a wave source as a consequence of the relative motion between the source and an observer. Veselago theoretically predicted that materials with negative refractions can induce inverse Doppler effects. With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally. Here, we demonstrated a method of designing and experimentally characterising arbitrary broadband acoustic metamaterials. These omni-directional, double-negative, acoustic metamaterials are constructed with 'flute-like' acoustic meta-cluster sets with seven double meta-molecules; these metamaterials also overcome the limitations of broadband negative bulk modulus and mass density to provide a region of negative refraction and inverse Doppler effects. It was also shown that inverse Doppler effects can be detected in a flute, which has been popular for thousands of years in Asia and Europe.

  15. Inverse Doppler Effects in Broadband Acoustic Metamaterials

    Science.gov (United States)

    Zhai, S. L.; Zhao, X. P.; Liu, S.; Shen, F. L.; Li, L. L.; Luo, C. R.

    2016-08-01

    The Doppler effect refers to the change in frequency of a wave source as a consequence of the relative motion between the source and an observer. Veselago theoretically predicted that materials with negative refractions can induce inverse Doppler effects. With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally. Here, we demonstrated a method of designing and experimentally characterising arbitrary broadband acoustic metamaterials. These omni-directional, double-negative, acoustic metamaterials are constructed with ‘flute-like’ acoustic meta-cluster sets with seven double meta-molecules; these metamaterials also overcome the limitations of broadband negative bulk modulus and mass density to provide a region of negative refraction and inverse Doppler effects. It was also shown that inverse Doppler effects can be detected in a flute, which has been popular for thousands of years in Asia and Europe.

  16. Observation of the Zero Doppler Effect

    Science.gov (United States)

    Ran, Jia; Zhang, Yewen; Chen, Xiaodong; Fang, Kai; Zhao, Junfei; Chen, Hong

    2016-04-01

    The normal Doppler effect has well-established applications in many areas of science and technology. Recently, a few experimental demonstrations of the inverse Doppler effect have begun to appear in negative-index metamaterials. Here we report an experimental observation of the zero Doppler effect, that is, no frequency shift irrespective of the relative motion between the wave signal source and the detector in a zero-index metamaterial. This unique phenomenon, accompanied by the normal and inverse Doppler effects, is generated by reflecting a wave from a moving discontinuity in a composite right/left-handed transmission line loaded with varactors when operating in the near zero-index passband, or the right/left-handed passband. This work has revealed a complete picture of the Doppler effect in metamaterials and may lead to potential applications in electromagnetic wave related metrology.

  17. Estimating the Doppler centroid of SAR data

    DEFF Research Database (Denmark)

    Madsen, Søren Nørvang

    1989-01-01

    After reviewing frequency-domain techniques for estimating the Doppler centroid of synthetic-aperture radar (SAR) data, the author describes a time-domain method and highlights its advantages. In particular, a nonlinear time-domain algorithm called the sign-Doppler estimator (SDE) is shown to have...... attractive properties. An evaluation based on an existing SEASAT processor is reported. The time-domain algorithms are shown to be extremely efficient with respect to requirements on calculations and memory, and hence they are well suited to real-time systems where the Doppler estimation is based on raw SAR...... data. For offline processors where the Doppler estimation is performed on processed data, which removes the problem of partial coverage of bright targets, the ΔE estimator and the CDE (correlation Doppler estimator) algorithm give similar performance. However, for nonhomogeneous scenes it is found...

  18. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1996-02-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the US Department of Energy (DOE). This document contains the planned 1996 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project.

  19. Color doppler sonography in thickened gallbladder wall

    Energy Technology Data Exchange (ETDEWEB)

    Han, Sang Suk; Choi, Seok Jin; Seo, Chang Hae; Eun, Choong Ki [Inje Univ. College of Medicine, Kimhae (Korea, Republic of)

    1996-11-01

    The thickening of the gallbladder wall is a valuable finding for the diagnosis of cholecystitis, but may be seen in non-cholecystic disease as well as in acute or chronic cholecystitis. The purpose of this study is to determine the value of color Doppler sonography in differentiating the causes of thickened gallbladder wall. Ninety eight patients with thickened gallbladder wall(more than 3mm) which was not due to gallbladder cancer were prospectively evaluated with color Doppler sonography. Sixty-six cases, confirmed by pathologic reports and clinical records, were analyzed for correlation between thickened gallbladder wall and color flow signal according to the underlying causes. Of the 66 patients, 28 cases were cholecystitis and 38 cases had non-cholecystic causes such as liver cirrhosis, ascites, hepatitis, pancreatitis, renal failure, and hypoalbuminemia. Of the 28 patients with cholecystitis(12 acute, 16 chronic), 23(82%) had color Doppler flow signals in the thickened gallbladder wall. Of the 38 patients with non-cholecystic causes, eight(21%) had color Doppler flow signals. There was a statistically significant difference of color Doppler flow signals between the cholecystitis and non-cholecystic groups(p=0.0001). No significant difference of color Doppler flow signals was found between cases of acute and chronic cholecystitis. Of the 23 patients with color Doppler flow signals in 28 cases of cholecystitis, 18(78.3%) showed a linear pattern and five(21.7%) showed a spotty pattern. Of the eight patients with color Doppler flow signals in the 38 non-cholecystic cases, four(50%) showed a linear pattern and four(50%) showed a spotty pattern. In cholecystitis, a linear color Doppler flow signal pattern is a much more frequent finding than a spotty pattern. Color Doppler sonography is a useful and adequate method for determining whether a thickened gallbladder wall is the result of cholecystitis or has non-cholecystic causes.

  20. Postmarketing surveillance for drug abuse.

    Science.gov (United States)

    Arfken, Cynthia L; Cicero, Theodore J

    2003-06-05

    Assessing actual abuse of prescribed medications requires postmarketing surveillance. In this article we discuss general systems of postmarketing surveillance that exist as of the end of 2002 in the United States and two medication-specific surveillance systems that were devised and tested. The two specific surveillance systems are compared with limitations highlighted. Postmarketing surveillance is in its infancy and requires more research on ways to improve its validity without inducing illicit experimentation. Information on comparator medications is highly recommended both to validate the system and to place the results in context.

  1. Optical Doppler tomography and spectral Doppler imaging of localized ischemic stroke in a mouse model

    Science.gov (United States)

    Yu, Lingfeng; Nguyen, Elaine; Liu, Gangjun; Rao, Bin; Choi, Bernard; Chen, Zhongping

    2010-02-01

    We present a combined optical Doppler tomography/spectral Doppler imaging modality to quantitatively evaluate the dynamic blood circulation and the artery blockage before and after a localized ischemic stroke in a mouse model. Optical Doppler Tomography (ODT) combines the Doppler principle with optical coherence tomography for noninvasive localization and measurement of particle flow velocity in highly scattering media with micrometer scale spatial resolution. Spectral Doppler imaging (SDI) provides complementary temporal flow information to the spatially distributed flow information of Doppler imaging. Fast, repeated, ODT scans across an entire vessel were performed to record flow dynamic information with high temporal resolution of cardiac cycles. Spectral Doppler analysis of continuous Doppler images demonstrates how the velocity components and longitudinally projected flow-volume-rate change over time for scatters within the imaging volume using spectral Doppler waveforms. Furthermore, vascular conditions can be quantified with various Doppler-angle-independent flow indices. Non-invasive in-vivo mice experiments were performed to evaluate microvascular blood circulation of a localized ischemic stroke mouse model.

  2. Wideband radar micro-doppler applications

    Science.gov (United States)

    Tahmoush, Dave

    2013-05-01

    Wideband radar provides a significant improvement over traditional narrowband radars for micro-Doppler analysis because the high bandwidth can be used to separate many of the signals in range, allowing a simpler decomposition of the micro-Doppler signals. Recent wideband radar work has focused on micro-Doppler, but there is a point where the narrowband approach used to analyze the micro-Doppler signals breaks down. The effect is shown to be independent of frequency, but the error relative to the bandwidth is shown to be inversely proportional to the frequency and proportional to the velocity of the subject. This error can create a smearing effect in the observed Doppler if it is not corrected, leading to reduced signal-to-noise and the appearance of more diffuse targets in Doppler space. In range-space, wideband data can also break the subject into several range bins, affecting the observed signal to noise ratio. The possible applications of wideband micro-Doppler radar are also shown, including the separation of arm movement from human motion which implies that the arms are not encumbered.

  3. Rotational Doppler effect in nonlinear optics

    Science.gov (United States)

    Li, Guixin; Zentgraf, Thomas; Zhang, Shuang

    2016-08-01

    The translational Doppler effect of electromagnetic and sound waves has been successfully applied in measurements of the speed and direction of vehicles, astronomical objects and blood flow in human bodies, and for the Global Positioning System. The Doppler effect plays a key role for some important quantum phenomena such as the broadened emission spectra of atoms and has benefited cooling and trapping of atoms with laser light. Despite numerous successful applications of the translational Doppler effect, it fails to measure the rotation frequency of a spinning object when the probing wave propagates along its rotation axis. This constraint was circumvented by deploying the angular momentum of electromagnetic waves--the so-called rotational Doppler effect. Here, we report on the demonstration of rotational Doppler shift in nonlinear optics. The Doppler frequency shift is determined for the second harmonic generation of a circularly polarized beam passing through a spinning nonlinear optical crystal with three-fold rotational symmetry. We find that the second harmonic generation signal with circular polarization opposite to that of the fundamental beam experiences a Doppler shift of three times the rotation frequency of the optical crystal. This demonstration is of fundamental significance in nonlinear optics, as it provides us with insight into the interaction of light with moving media in the nonlinear optical regime.

  4. Staggered Multiple-PRF Ultrafast Color Doppler.

    Science.gov (United States)

    Posada, Daniel; Poree, Jonathan; Pellissier, Arnaud; Chayer, Boris; Tournoux, Francois; Cloutier, Guy; Garcia, Damien

    2016-06-01

    Color Doppler imaging is an established pulsed ultrasound technique to visualize blood flow non-invasively. High-frame-rate (ultrafast) color Doppler, by emissions of plane or circular wavefronts, allows severalfold increase in frame rates. Conventional and ultrafast color Doppler are both limited by the range-velocity dilemma, which may result in velocity folding (aliasing) for large depths and/or large velocities. We investigated multiple pulse-repetition-frequency (PRF) emissions arranged in a series of staggered intervals to remove aliasing in ultrafast color Doppler. Staggered PRF is an emission process where time delays between successive pulse transmissions change in an alternating way. We tested staggered dual- and triple-PRF ultrafast color Doppler, 1) in vitro in a spinning disc and a free jet flow, and 2) in vivo in a human left ventricle. The in vitro results showed that the Nyquist velocity could be extended to up to 6 times the conventional limit. We found coefficients of determination r(2) ≥ 0.98 between the de-aliased and ground-truth velocities. Consistent de-aliased Doppler images were also obtained in the human left heart. Our results demonstrate that staggered multiple-PRF ultrafast color Doppler is efficient for high-velocity high-frame-rate blood flow imaging. This is particularly relevant for new developments in ultrasound imaging relying on accurate velocity measurements.

  5. Internet and Surveillance

    DEFF Research Database (Denmark)

    The Internet has been transformed in the past years from a system primarily oriented on information provision into a medium for communication and community-building. The notion of “Web 2.0”, social software, and social networking sites such as Facebook, Twitter and MySpace have emerged in this co......The Internet has been transformed in the past years from a system primarily oriented on information provision into a medium for communication and community-building. The notion of “Web 2.0”, social software, and social networking sites such as Facebook, Twitter and MySpace have emerged...... in the age of the internet; civil watch-surveillance on social networking sites; and networked interactive surveillance in transnational space. This book is a result of a research action launched by the intergovernmental network COST (European Cooperation in Science and Technology)....

  6. Surface-water surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Saldi, K.A.; Dirkes, R.L.; Blanton, M.L.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the Surface water on and near the Hanford Site is monitored to determine the potential effects of Hanford operations. Surface water at Hanford includes the Columbia River, riverbank springs, ponds located on the Hanford Site, and offsite water systems directly east and across the Columbia River from the Hanford Site, and offsite water systems directly east and across the Columbia River from the Hanford Site. Columbia River sediments are also included in this discussion. Tables 5.3.1 and 5.3.2 summarize the sampling locations, sample types, sampling frequencies, and sample analyses included in surface-water surveillance activities during 1994. Sample locations are also identified in Figure 5.3.1. This section describes the surveillance effort and summarizes the results for these aquatic environments. Detailed analytical results are reported by Bisping (1995).

  7. Surveillance for gastrointestinal malignancies

    Institute of Scientific and Technical Information of China (English)

    Ashish K Tiwari; Heather S Laird-Fick; Ramesh K Wali; Hemant K Roy

    2012-01-01

    Gastrointestinal (GI) malignancies are notorious for frequently progressing to advanced stages even in the absence of serious symptoms,thus leading to delayed diagnoses and dismal prognoses.Secondary prevention of GI malignancies through early detection and treatment of cancer-precursor/premalignant lesions,therefore,is recognized as an effective cancer prevention strategy.In order to efficiently detect these lesions,systemic application of screening tests (surveillance) is needed.However,most of the currently used non-invasive screening tests for GI malignancies (for example,serum markers such as alpha-fetoprotein for hepatocellular carcinoma,and fecal occult blood test,for colon cancer) are only modestly effective necessitating the use of highly invasive endoscopy-based procedures,such as esophagogastroduodenoscopy and colonoscopy for screening purposes.Even for hepatocellular carcinoma where non-invasive imaging (ultrasonography) has become a standard screening tool,the need for repeated liver biopsies of suspicious liver nodules for histopathological confirmation can't be avoided.The invasive nature and high-cost associated with these screening tools hinders implementation of GI cancer screening programs.Moreover,only a small fraction of general population is truly predisposed to developing GI malignancies,and indeed needs surveillance.To spare the average-risk individuals from superfluous invasive procedures and achieve an economically viable model of cancer prevention,it's important to identify cohorts in general population that are at substantially high risk of developing GI malignancies (riskstratification),and select suitable screening tests for surveillance in these cohorts.We herein provide a brief overview of such high-risk cohorts for different GI malignancies,and the screening strategies that have commonly been employed for surveillance purpose in them.

  8. Ocean surveillance satellites

    Science.gov (United States)

    Laurent, D.

    Soviet and U.S. programs involving satellites for surveillance of ships and submarines are discussed, considering differences in approaches. The Soviet program began with the Cosmos 198 in 1967 and the latest, the Cosmos 1400 series, 15 m long and weighing 5 tons, carry radar for monitoring ships and a nuclear reactor for a power supply. Other Soviet spacecraft carrying passive microwave sensors and ion drives powered by solar panels have recently been detonated in orbit for unknown reasons. It has also been observed that the Soviet satellites are controlled in pairs, with sequential orbital changes for one following the other, and both satellites then overflying the same points. In contrast, U.S. surveillance satellites have been placed in higher orbits, thus placing greater demands on the capabilities of the on-board radar and camera systems. Project White Cloud and the Clipper Bow program are described, noting the continued operation of the White Cloud spacecraft, which are equipped to intercept radio signals from surface ships. Currently, the integrated tactical surveillance system program has completed its study and a decision is expected soon.

  9. History of trichinellosis surveillance

    Directory of Open Access Journals (Sweden)

    Blancou J.

    2001-06-01

    Full Text Available The origin of trichinellosis, which existed in ancient times as testified by the discovery of parasite larvae on an Egyptian mummy, unfolded in several stages: discovery of encapsulated larvae (in the 1820s, identification and scientific description of these larvae (Paget Owen, 1835, followed by experimental infestations of animals (dogs, pigs, rabbits, mice or of humans as from 1850.The main occurrences of trichinellosis were followed with particular attention in Europe (Germany, Denmark, France, etc. and in the United States of America at the end of the XIXth century. They affected numerous domestic animal species (pigs, horses, etc. or wildlife and humans. Germany paid the heaviest toll with regard to the disease in humans, between 1860 and 1880, with several thousands of patients and more than 500 deaths.Different trichinellosis surveillance systems were set up in the relevant countries in the 1860s. In humans, this surveillance was carried out on affected living patients by a biopsy of the biceps muscles and subsequently by an analysis of eosinophilia (1895. In animals, surveillance was for a long time solely based on postmortem examination of the muscles of the affected animals. This method was used for the first time in 863 in Germany, and from the 1 890s, on several hundreds of thousands of pigs in Europe or in the United States of America.

  10. Doppler backscatter properties of a blood-mimicking fluid for Doppler performance assessment.

    Science.gov (United States)

    Ramnarine, K V; Hoskins, P R; Routh, H F; Davidson, F

    1999-01-01

    The Doppler backscatter properties of a blood-mimickig fluid (BMF) were studied to evaluate its suitability for use in a Doppler flow test object. Measurements were performed using a flow rig with C-flex tubing and BMF flow produced by a roller pump or a gear pump. A SciMed Doppler system was used to measure the backscattered Doppler power with a root-mean-square power meter connected to the audio output. Studies investigated the dependence of the backscattered Doppler power of the BMF with: circulation time; batch and operator preparations; storage; sieve size; flow speed; and pump type. A comparison was made with human red blood cells resuspended in saline. The backscatter properties are stable and within International Electrotechnical Commission requirements. The BMF is suitable for use in a test object for Doppler performance assessment.

  11. Doppler echocardiography in normal functioning valve prostheses.

    Science.gov (United States)

    Cha, R; Yang, S S; Salvucci, T; DiBlasi, S

    1994-09-01

    Even though there has been some criticism regarding the Doppler evaluation in prosthetic valves because of inter-observer and intra-observer variability, among other factors, and Doppler study has a tendency to have falsely high gradients compared to invasive studies, especially mechanical aortic prostheses, Doppler evaluation can provide reliable hemodynamic information about valve function. This test may be particularly useful if used serially, when baseline values are known. Doppler measurement of gradient and valve area has an expected normal range that is specific for the prosthetic type, size, anatomical position, and chronological age. Clearly, a database involving these aspects is needed to provide a more accurate normal range. This study is intended to provide guidance for echocardiographers.

  12. Teaching the Doppler effect in astrophysics

    Science.gov (United States)

    Hughes, Stephen W.; Cowley, Michael

    2017-03-01

    The Doppler effect is a shift in the frequency of waves emitted from an object moving relative to the observer. By observing and analysing the Doppler shift in electromagnetic waves from astronomical objects, astronomers gain greater insight into the structure and operation of our Universe. In this paper, a simple technique is described for teaching the basics of the Doppler effect to undergraduate astrophysics students using acoustic waves. An advantage of the technique is that it produces a visual representation of the acoustic Doppler shift. The equipment comprises a 40 kHz acoustic transmitter and a microphone. The sound is bounced off a computer fan and the signal collected by a DrDAQ ADC and processed by a spectrum analyser. Widening of the spectrum is observed as the fan power supply potential is increased from 4 to 12 V.

  13. High range resolution micro-Doppler analysis

    Science.gov (United States)

    Cammenga, Zachary A.; Smith, Graeme E.; Baker, Christopher J.

    2015-05-01

    This paper addresses use of the micro-Doppler effect and the use of high range-resolution profiles to observe complex targets in complex target scenes. The combination of micro-Doppler and high range-resolution provides the ability to separate the motion of complex targets from one another. This ability leads to the differentiation of targets based on their micro-Doppler signatures. Without the high-range resolution, this would not be possible because the individual signatures would not be separable. This paper also addresses the use of the micro-Doppler information and high range-resolution profiles to generate an approximation of the scattering properties of a complex target. This approximation gives insight into the structure of the complex target and, critically, is created without using a pre-determined target model.

  14. High Throughput Direct Detection Doppler Lidar Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Lite Cycles, Inc. (LCI) proposes to develop a direct-detection Doppler lidar (D3L) technology called ELITE that improves the system optical throughput by more than...

  15. Student Microwave Experiments Involving the Doppler Effect.

    Science.gov (United States)

    Weber, F. Neff; And Others

    1980-01-01

    Described is the use of the Doppler Effect with microwaves in the measurement of the acceleration due to gravity of falling objects. The experiments described add to the repertoire of quantitative student microwave experiments. (Author/DS)

  16. Inverse Doppler Effects in Broadband Acoustic Metamaterials

    National Research Council Canada - National Science Library

    Zhai, S L; Zhao, X P; Liu, S; Shen, F L; Li, L L; Luo, C R

    2016-01-01

    .... With the development of metamaterials, inverse Doppler effects have been extensively investigated. However, the ideal material parameters prescribed by these metamaterial design approaches are complex and also challenging to obtain experimentally...

  17. Optical Doppler shift with structured light

    OpenAIRE

    2011-01-01

    When a light beam with a transverse spatially varying phase is considered for optical remote sensing, in addition to the usual longitudinal Doppler frequency shift of the returned signal induced by the motion of the scatter along the beam axis, a new transversal Doppler shift appears associated to the motion of the scatterer in the plane perpendicular to the beam axis. We discuss here how this new effect can be used to enhance the current capabilities of optical measurement system...

  18. with Ultrasound Color Doppler Imaging

    Directory of Open Access Journals (Sweden)

    Shin Takayama

    2012-01-01

    Full Text Available Color Doppler imaging (CDI can be used to noninvasively create images of human blood vessels and quantitatively evaluate blood flow in real-time. The purpose of this study was to assess the effects of acupuncture on the blood flow of the peripheral, mesenteric, and retrobulbar arteries by CDI. Statistical significance was defined as P values less than 0.05. Blood flow in the radial and brachial arteries was significantly lower during needle stimulation on LR3 than before in healthy volunteers, but was significantly higher after needle stimulation than before. LR3 stimulation also resulted in a significant decrease in the vascular resistance of the short posterior ciliary artery and no significant change of blood flow through the superior mesenteric artery (SMA during acupuncture. In contrast, ST36 stimulation resulted in a significant increase in blood flow through the SMA and no significant change in the vascular resistance of the retrobulbar arteries. Additionally, acupuncture at previously determined acupoints in patients with open-angle glaucoma led to a significant reduction in the vascular resistance of the central retinal artery and short posterior ciliary artery. Our results suggest that acupuncture can affect blood flow of the peripheral, mesenteric, and retrobulbar arteries, and CDI can be useful to evaluate hemodynamic changes by acupuncture.

  19. Doppler micro sense and avoid radar

    Science.gov (United States)

    Gorwara, Ashok; Molchanov, Pavlo; Asmolova, Olga

    2015-10-01

    There is a need for small Sense and Avoid (SAA) systems for small and micro Unmanned Aerial Systems (UAS) to avoid collisions with obstacles and other aircraft. The proposed SAA systems will give drones the ability to "see" close up and give them the agility to maneuver through tight areas. Doppler radar is proposed for use in this sense and avoid system because in contrast to optical or infrared (IR) systems Doppler can work in more harsh conditions such as at dusk, and in rain and snow. And in contrast to ultrasound based systems, Doppler can better sense small sized obstacles such as wires and it can provide a sensing range from a few inches to several miles. An SAA systems comprised of Doppler radar modules and an array of directional antennas that are distributed around the perimeter of the drone can cover the entire sky. These modules are designed so that they can provide the direction to the obstacle and simultaneously generate an alarm signal if the obstacle enters within the SAA system's adjustable "Protection Border". The alarm signal alerts the drone's autopilot to automatically initiate an avoidance maneuver. A series of Doppler radar modules with different ranges, angles of view and transmitting power have been designed for drones of different sizes and applications. The proposed Doppler radar micro SAA system has simple circuitry, works from a 5 volt source and has low power consumption. It is light weight, inexpensive and it can be used for a variety of small unmanned aircraft.

  20. The Doppler effect in NMR spectroscopy.

    Science.gov (United States)

    Guéron, Maurice

    2003-02-01

    An NMR sample may be subject to motions, such as those due to sample spinning or to liquid flow. Is the spectrum of such a sample affected by the Doppler effect? The question arises because, instrumental dimensions being much shorter than the wavelength, it is the near-field of the precessing magnetic moment which couples to the receiver coil, rather than the radiated far-field. We expand the near-field into plane propagating waves. For each such wave there is another one with the same amplitude, propagating in the opposite direction. The Doppler shifts are therefore equal and opposite. In the model case of a small fluid sample moving with constant velocity, this leads to a distribution of Doppler shifts which is symmetrical with respect to the unshifted frequency: there is no net spectral shift. We examine the possibility of observing the Doppler distribution in this case. We also consider the case of thermal motion of a gas. We draw attention to the resolved Doppler splitting of molecular rotational transitions in a supersonic burst as observed in a microwave resonator. We also mention briefly the Doppler effect in molecular beam spectroscopy.

  1. AIDS-case surveillance.

    Science.gov (United States)

    Lal, S; Khodakevich, L; Sengupta, D

    1994-01-01

    In 1991 in India, the Ministry of Health realized that the diagnostic and reporting network for AIDS cases was inadequate as AIDS cases grew and that the establishment of specialized AIDS units in hospitals was not the best strategy. It decided to integrate AIDS diagnostic and management facilities into primary health services. It would arrange training for 1 physician from each district and peripheral hospital, private hospital, and inpatient service of other medical institutions in AIDS diagnosis and management. These physicians would then train others in the clinical diagnosis and management of AIDS cases. The physicians would use the World Health Organization [WHO] case definition of AIDS supported by HIV serological test results. All AIDS cases would be transferred to the Medical College Hospitals of the States and Union Territories (UTs), regional hospitals, and perhaps some private hospitals. Between May 1986 and October 1993, India had 459 AIDS cases reported from 19 States and UTs, especially the States of Tamil Nadul and Maharashtra. This AIDS case surveillance system should motivate political will, describe the underlying and preceding HIV epidemic, and contribute to the understanding of current and future course of the epidemic. Thus, it will guide decision makers to develop sound preventive strategies, to plan health care, and to evaluate interventions. The surveillance system's target population is all outpatients and inpatients at medical institutions. During 1993-1994, 1000 hospitals should make up the network of referral institutions. AIDS case surveillance coordinators (ASCs) at each institution form the basis of the network. The individual case record of each suspected AIDS case will have details on his/her life and medical history. Records of confirmed cases will be sent to State ASCs who will compile them for the National AIDS Control Organisation. After 3-4 year of training and practice in AIDS diagnosis and reporting, AIDS reporting will be

  2. GSFC Supplier Surveillance

    Science.gov (United States)

    Kelly, Michael P.

    2011-01-01

    Topics covered include: Develop Program/Project Quality Assurance Surveillance Plans The work activities performed by the developer and/or his suppliers are subject to evaluation and audit by government-designated representatives. CSO supports project by selecting on-site supplier representative s by one of several methods: (1) a Defense Contract Management Agency (DCMA) person via a Letter Of Delegation (LOD), (2) an independent assurance contractor (IAC) via a contract Audits, Assessments, and Assurance (A3) Contract Code 300 Mission Assurance Support Contract (MASC)

  3. Bodygraphic Injury Surveillance System

    Science.gov (United States)

    Tsuboi, Toshiki; Kitamura, Koji; Nishida, Yoshihumi; Motomura, Yoichi; Takano, Tachio; Yamanaka, Tatsuhiro; Mizoguchi, Hiroshi

    This paper proposes a new technology,``a bodygraphic injury surveillance system (BISS)'' that not only accumulates accident situation data but also represents injury data based on a human body coordinate system in a standardized and multilayered way. Standardized and multilayered representation of injury enables accumulation, retrieval, sharing, statistical analysis, and modeling causalities of injury across different fields such as medicine, engineering, and industry. To confirm the effectiveness of the developed system, the authors collected 3,685 children's injury data in cooperation with a hospital. As new analyses based on the developed BISS, this paper shows bodygraphically statistical analysis and childhood injury modeling using the developed BISS and Bayesian network technology.

  4. Projectbeschrijving Surveillance Ziekenhuisinfecties 1996-1999

    NARCIS (Netherlands)

    Berg JMJ van den; Boer AS de; Mintjes-de Groot AJ; Sprenger MJW; Cucic S; Pelt W van; Centraal Begeleidingsorgaan; CIE

    1996-01-01

    In the Project Surveillance Hospital Acquired Infections a surveillance system in a national network of hospitals is being developed and implemented. In the project surveillance of hospital acquired infections is implemented in components: surveillance of surgical wound infections, surveillance of i

  5. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Directory of Open Access Journals (Sweden)

    Sumit Goel

    2011-01-01

    Full Text Available Aim: To evaluate the efficacy of ultrasonography (USG with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas. There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions.

  6. Sonoma Persistent Surveillance System

    Energy Technology Data Exchange (ETDEWEB)

    Pennington, D M

    2006-03-24

    Sonoma offers the first cost-effective, broad-area, high-resolution, real-time motion imagery system for surveillance applications. Sonoma is unique in its ability to provide continuous, real-time video imagery of an area the size of a small city with resolutions sufficient to track 8,000 moving objects in the field of view. At higher resolutions and over smaller areas, Sonoma can even track the movement of individual people. The visual impact of the data available from Sonoma is already causing a paradigm shift in the architecture and operation of other surveillance systems. Sonoma is expected to cost just one-tenth the price of comparably sized sensor systems. Cameras mounted on an airborne platform constantly monitor an area, feeding data to the ground for real-time analysis. Sonoma was designed to provide real-time data for actionable intelligence in situations such as monitoring traffic, special events, border security, and harbors. If a Sonoma system had been available in the aftermath of the Katrina and Rita hurricanes, emergency responders would have had real-time information on roads, water levels, and traffic conditions, perhaps saving many lives.

  7. A new computerized program for surveillance of prosthetic arteriovenous fistulas

    Directory of Open Access Journals (Sweden)

    Matteo Tozzi

    2015-05-01

    Full Text Available Stenosis and thrombosis are common causes of prosthetic vascular access (pVA failure. The role of arteriovenous fistula (AVF surveillance is widely debated. The aim of this paper is to present a new real-time application designed for AVF surveillance called SPIDER. Surgical staff and hemodialysis nurses are responsible for data entry. SPIDER automatically analyses data and generates alerts in case of abnormal trends. Surgical evaluation and duplex Doppler ultrasonography are then immediately performed to confirm presence of stenosis or other possible pVA defects. Surgery can be performed if required. A preliminary analysis of results will be completed at 12 months after the program begins and subsequently after 24 months. Primary assisted patency will be compared with historical using multivariate analysis. Expected results are an improvement in primary assisted pVA patency and reduction of hospitalizations. Simultaneous management of a high number of patients can become difficult due to the large amount of data required for surveillance. We want to demonstrate whether a real-time automated system could help to prevent thrombosis and graft loss.

  8. Surveillance theory and its implications for law

    NARCIS (Netherlands)

    Timan, Tjerk; Galic, Masa; Koops, Bert-Jaap; Yeung, Karen; Brownsword, Roger; Scotford, Eloise

    2016-01-01

    This chapter provides an overview of key surveillance theories and their implications for law and regulation. It presents three stages of theories that characterise changes in thinking about surveillance in society and the disciplining, controlling, and entertaining functions of surveillance.

  9. Development of the doppler electron velocimeter: theory.

    Energy Technology Data Exchange (ETDEWEB)

    Reu, Phillip L.

    2007-03-01

    Measurement of dynamic events at the nano-scale is currently impossible. This paper presents the theoretical underpinnings of a method for making these measurements using electron microscopes. Building on the work of Moellenstedt and Lichte who demonstrated Doppler shifting of an electron beam with a moving electron mirror, further work is proposed to perfect and utilize this concept in dynamic measurements. Specifically, using the concept of ''fringe-counting'' with the current principles of transmission electron holography, an extension of these methods to dynamic measurements is proposed. A presentation of the theory of Doppler electron wave shifting is given, starting from the development of the de Broglie wave, up through the equations describing interference effects and Doppler shifting in electron waves. A mathematical demonstration that Doppler shifting is identical to the conceptually easier to understand idea of counting moving fringes is given by analogy to optical interferometry. Finally, potential developmental experiments and uses of a Doppler electron microscope are discussed.

  10. Defining 'surveillance' in drug safety.

    Science.gov (United States)

    Aronson, Jeffrey K; Hauben, Manfred; Bate, Andrew

    2012-05-01

    The concept of surveillance in pharmacovigilance and pharmacoepidemiology has evolved from the concept of surveillance in epidemiology, particularly of infectious diseases. We have surveyed the etymology, usages, and previous definitions of 'surveillance' and its modifiers, such as 'active' and 'passive'. The following essential definitional features of surveillance emerge: (i) surveillance and monitoring are different--surveillance involves populations, while monitoring involves individuals; (ii) surveillance can be performed repeatedly and at any time during the lifetime of a medicinal product or device; (iii) although itself non-interventional, it can adduce any types of evidence (interventional, observational, or anecdotal, potentially at different times); (iv) it encompasses data collection, management, analysis, and interpretation; (v) it includes actions to be taken after signal detection, including initial evaluation and communication; and (vi) it should contribute to the classification of adverse reactions and their prevention or mitigation and/or to the harnessing of beneficial effects. We conclude that qualifiers add ambiguity and uncertainty without enhancing the idea of surveillance. We propose the following definition of surveillance of health-care products, which embraces all the surveyed ideas and reflects real-world pharmacovigilance processes: 'a form of non-interventional public health research, consisting of a set of processes for the continued systematic collection, compilation, interrogation, analysis, and interpretation of data on benefits and harms (including relevant spontaneous reports, electronic medical records, and experimental data).' As a codicil, we note that the purposes of surveillance are to identify, evaluate, understand, and communicate previously unknown effects of health-care products, or new aspects of known effects, in order to harness such effects (if beneficial) or prevent or mitigate them (if harmful).

  11. Self-surveillance

    DEFF Research Database (Denmark)

    Albrechtslund, Anders

    coupled with social interaction and sometimes framed as entertainment or games. Facilitated by online community and social networking sites, the possibility of collecting and sharing data is a significant feature of these self-monitoring technologies. They all include sharing features where weight, blood...... pressure, fitness activities, sleep cycles, etc. can be broadcasted, e.g. as tweets on Twitter or status updates on Facebook. Such quantification practices with monitoring technologies become co-producing when individuals constitute themselves as subjects engaging in self-tracking, self-care, and self......, and gamification modulate the enactment of selfhood? How does self-surveillance contribute to corresponding notions of self-optimization and self-cultivation such as “the good life”, “sustainable lifestyle”, “healthy living”, “good learning” and “work productivity”?...

  12. Drug approval and surveillance.

    Science.gov (United States)

    Potts, M

    1980-01-01

    This article argues that current regulations governing the licensing of drugs, particularly in the U.S., need to be changed and replaced by a system of provisional or conditional licensing and increased postmarketing surveillance of drug use. In terms of research and development of new forms of contraception, this proposal would have great impact. It is believed that the U.S./Food and Drug Administration (FDA) requirements--animal experiments and Phase 1 and 2 clinical trials--not only put an unacceptable financial burden on any institution attempting to develop new contraceptives, but do not demonstrably contribute to the reduction of risks. The author questions whether even if oral contraceptives introduced prior to new U.S./FDA regulations had been subject to these current regulations that convincing evidence would have been found to alert anyone to the now-known rare adverse effects, such as risk of thromboembolism. It is pointed out that these sorts of rare risks were uncovered by continuous screening processes which are not now a part of the FDA drug regulation requirements. The author also questions the politics of "conpulsory safety," such as might be legislated for regulated car safety belt use. Citing a partnership already established between government and private industry in high-risk/low cost ventures in the aerospace industry, the author sees no reason why such a relationship could not evolve in the pharmaceutical industry. In Britain, proposals have been made to establish a fund to compensate patients adversely affected by drugs which pharmaceutical companies would reimburse if proved negligent; such a fund may work in the U.S. under new regulations which stress postmarketing surveillance.

  13. Secure surveillance videotapes

    Energy Technology Data Exchange (ETDEWEB)

    Resnik, W.M.; Kadner, S.P. [Aquila Technologies Group, Inc., Albuquerque, NM (United States); Olsen, R.; Chitumbo, K. [International Atomic Energy Agency, Vienna (Austria); Pepper, S. [International Safeguards Project Office, Vienna (Austria)

    1995-12-31

    With assistance from the US Program for Technical Assistance to IAEA Safeguards (POTAS), Aquila Technologies Group developed the Tamper-Resistant Analog Media (TRAM-1000) system to provide standard VHS surveillance video tapes with an enhanced tamper-indicating capability. This project represents further implementation of the partnership approach in facilities including light water reactors with MOX facilities. These facilities use Uniplex Digiquad system video tapes. The partnership approach ensures that one organization can exchange the tapes in a machine without the presence of the other, without losing continuity of information. The TRAM-1000 system development project was accomplished in two stages. In the first stage of the project, the original system delivered to the IAEA, consists of three parts: (1) the tamper detection unit, (2) a specially augmented VHS video tape, and (3) an HP-95 reader. The tamper detection unit houses a VACOSS active fiber-optic seal and an electronic identification tag (E-TAG) reader. In the second stage of the project, the original TRAM-1000 was modified to its current design based on agency input. After delivery of the original TRAM-1000 system to the IAEA, it was reviewed by inspectors. The inspectors felt that the initial system`s tape storage/transport method could be simplified. Rather than threading the fiber through the tape spindles, the inspectors suggested that the tape be placed in a bag capable of being sealed. Also, a more flexible fiber-optic cable was recommended. As a result of these suggestions, Aquila developed a tamper-proof bag specifically for holding a surveillance video tape and sealable with a VACOSS fiber optical seal.

  14. Diabetic Nephropathy : Evaluation with Doppler Ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Sim, Jung Suk; Kim, Seung Hyup; Kang, Heung Sik; Park, Jae Hyung; Han, Man Chung [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1996-06-15

    To compare Doppler ultrasonography with laboratory tests in evaluation of diabetic nephropathy. Fifty-five patients (mean age = 60, M : F = 26 : 29) with diabetes mellitus underwent renal Doppler ultrasonography. Resistive indices were compared with degree of proteinuria, serum creatinine level, and creatinine clearance rate. Eighteen patients who showed no proteinuria or microscopic proteinuria had a mean resistive index (RI) of 0.72 (SD, 0.05), 16 patients with macroscopic proteinuria without nephrotic syndrome had a mean RI of 0.82 (SD, 0.13), and 21 patients with nephrotic syndrome had a mean RI of 0.90 (SD, 0.12). Renal RI correlated highly with serum creatinine level (r = 0.62) and creatinine clearance rate (r = -0.43). Renal Doppler ultrasonography provides a useful indication of renal function in diabetic nephropathy but cannot offer an advantage over conventional laboratory test

  15. Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

    Science.gov (United States)

    Roberts, B.

    1986-01-01

    The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

  16. Color Doppler ultrasonography evaluation of amblyopia

    Directory of Open Access Journals (Sweden)

    Ece Turan-Vural

    2013-07-01

    Full Text Available AIM: To assess the hemodynamic changes in the extraocular orbital vessels of amblyopic patients in comparison with non-amblyopic fellow eyes, using color Doppler ultrasonography(CDU. METHODS: Thirty-six eyes of 18 pediatric patients were included in the study(20 amblyopic, 16 normal. All eyes underwent color Doppler ultrasonography examination of ophthalmic artery, central retinal artery, and posterior ciliary artery. RESULTS: The only differences between the two groups with regard to color Doppler ultrasonography parameters was the significantly lower peak systolic velocity(32.70±11.60 vs 55.01±11.68, P=0.001and end-diastolic velocity(6.83±1.91 vs 13.99±4.15, P=0.001for ophthalmic artery in amblyopic eyes.CONCLUSION: Our study showed amblyopic eyes may present a decrease in retrobulbar blood flow velocity.

  17. Observation of the inverse Doppler effect.

    Science.gov (United States)

    Seddon, N; Bearpark, T

    2003-11-28

    We report experimental observation of an inverse Doppler shift, in which the frequency of a wave is increased on reflection from a receding boundary. This counterintuitive effect has been produced by reflecting a wave from a moving discontinuity in an electrical transmission line. Doppler shifts produced by this system can be varied in a reproducible manner by electronic control of the transmission line and are typically five orders of magnitude greater than those produced by solid objects with kinematic velocities. Potential applications include the development of tunable and multifrequency radiation sources.

  18. Reversed Doppler effect in photonic crystals.

    Science.gov (United States)

    Reed, Evan J; Soljacić, Marin; Joannopoulos, John D

    2003-09-26

    Nonrelativistic reversed Doppler shifts have never been observed in nature and have only been speculated to occur in pathological systems with simultaneously negative effective permittivity and permeability. This Letter presents a different, new physical phenomenon that leads to a nonrelativistic reversed Doppler shift in light. It arises when light is reflected from a moving shock wave propagating through a photonic crystal. In addition to reflection of a single frequency, multiple discrete reflected frequencies or a 10 GHz periodic modulation can also be observed when a single carrier frequency of wavelength 1 microm is incident.

  19. Preprocessing of ionospheric echo Doppler spectra

    Institute of Scientific and Technical Information of China (English)

    FANG Liang; ZHAO Zhengyu; WANG Feng; SU Fanfan

    2007-01-01

    The real-time information of the distant ionosphere can be acquired by using the Wuhan ionospheric oblique backscattering sounding system(WIOBSS),which adopts a discontinuous wave mechanism.After the characteristics of the ionospheric echo Doppler spectra were analyzed,the signal preprocessing was developed in this paper,which aimed at improving the Doppler spectra.The results indicate that the preprocessing not only makes the system acquire a higher ability of target detection but also suppresses the radio frequency interference by 6-7 dB.

  20. Optical Doppler shift with structured light.

    Science.gov (United States)

    Belmonte, Aniceto; Torres, Juan P

    2011-11-15

    When a light beam with a transverse spatially varying phase is considered for optical remote sensing, in addition to the usual longitudinal Doppler frequency shift of the returned signal induced by the motion of the scatter along the beam axis, a new transversal Doppler shift appears associated to the motion of the scatterer in the plane perpendicular to the beam axis. We discuss here how this new effect can be used to enhance the current capabilities of optical measurement systems, adding the capacity to detect more complex movements of scatters.

  1. Magnetic Doppler Imaging of Active Stars

    CERN Document Server

    Kochukhov, O

    2007-01-01

    We present a new implementation of the magnetic Doppler imaging technique, which aims at self-consistent temperature and magnetic mapping of the surface structures in cool active stars. Our magnetic imaging procedure is unique in its capability to model individual spectral features in all four Stokes parameters. We discuss performance and intrinsic limitations of the new magnetic Doppler imaging method. A special emphasis is given to the simultaneous modelling of the magnetically sensitive lines in the optical and infrared regions and to combining information from both atomic and molecular spectral features. These two techniques may, for the first time, give us a tool to study magnetic fields in the starspot interiors.

  2. Review of Australia's polio surveillance.

    Science.gov (United States)

    Paterson, Beverley J; Durrheim, David N

    2013-06-30

    With eradication almost within reach, the importance of detecting every poliomyelitis case has taken on additional significance. The selected surveillance strategy must be effective and efficient. A review of polio surveillance in Australia was conducted to consider whether current strategies were optimal. Document review and semi-structured key informant interviews were used to conduct the review. Interviews were recorded, transcribed and thematically analysed. The review was an iterative process with feedback on the findings sought from interviewees. Since Western Pacific Regional polio-elimination status was certified, one imported adult case was detected in 2007 in Australia, with no evidence of further transmission, and no Australian paediatric cases identified. Respondents reported that: it was not possible to prevent importations; paediatric cases were more likely to be identified than adult cases; and there may be a low level of suspicion among clinicians. Case detection and outbreak mitigation were considered key reasons to undertake polio surveillance. While Australia has not achieved one of the key World Health Organization (WHO) surveillance targets, this did not compromise Australias polio-free status. Identified issues with polio surveillance were the potential for an importation with high attendant investigation and containment costs, low stool sample collection rates, and the opportunity to improve safeguards around the importation and laboratory storage of biological samples containing poliovirus. The review found strong support for ongoing polio surveillance, particularly to detect imported cases and to demonstrate commitment to maintaining a polio-free region. Existing polio surveillance strategies were considered appropriate for Australia.

  3. Operational Bright-Band Snow Level Detection Using Doppler Radar

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A method to detect the bright-band snow level from radar reflectivity and Doppler vertical velocity data collection with an atmospheric profiling Doppler radar. The...

  4. ISAR imaging using the instantaneous range instantaneous Doppler method

    CSIR Research Space (South Africa)

    Wazna, TM

    2015-10-01

    Full Text Available In Inverse Synthetic Aperture Radar (ISAR) imaging, the Range Instantaneous Doppler (RID) method is used to compensate for the nonuniform rotational motion of the target that degrades the Doppler resolution of the ISAR image. The Instantaneous Range...

  5. Fish embryo multimodal imaging by laser Doppler digital holography

    CERN Document Server

    Verrier, Nicolas; Picart, Pascal; Gross, Michel

    2015-01-01

    A laser Doppler imaging scheme combined to an upright microscope is proposed. Quantitative Doppler imaging in both velocity norm and direction, as well as amplitude contrast of either zebrafish flesh or vasculature is demonstrated.

  6. Photoacoustic Doppler flow measurement in optically scattering media

    Science.gov (United States)

    Fang, Hui; Maslov, Konstantin; Wang, Lihong V.

    2007-12-01

    We recently observed the photoacoustic Doppler effect from flowing small light-absorbing particles. Here, we apply the effect to measure blood-mimicking fluid flow in an optically scattering medium. The light scattering in the medium decreases the amplitude of the photoacoustic Doppler signal but does not affect either the magnitude or the directional discrimination of the photoacoustic Doppler shift. This technology may hold promise for a new Doppler method for measuring blood flow in microcirculation with high sensitivity.

  7. Acoustic micro-Doppler radar for human gait imaging.

    Science.gov (United States)

    Zhang, Zhaonian; Pouliquen, Philippe O; Waxman, Allen; Andreou, Andreas G

    2007-03-01

    A portable acoustic micro-Doppler radar system for the acquisition of human gait signatures in indoor and outdoor environments is reported. Signals from an accelerometer attached to the leg support the identification of the components in the measured micro-Doppler signature. The acoustic micro-Doppler system described in this paper is simpler and offers advantages over the widely used electromagnetic wave micro-Doppler radars.

  8. Photoacoustic Doppler effect from flowing small light-absorbing particles.

    Science.gov (United States)

    Fang, Hui; Maslov, Konstantin; Wang, Lihong V

    2007-11-01

    From the flow of a suspension of micrometer-scale carbon particles, the photoacoustic Doppler shift is observed. As predicted theoretically, the observed Doppler shift equals half of that in Doppler ultrasound and does not depend on the direction of laser illumination. This new physical phenomenon provides a basis for developing photoacoustic Doppler flowmetry, which can potentially be used for detecting fluid flow in optically scattering media and especially low-speed blood flow of relatively deep microcirculation in biological tissue.

  9. Tissue Doppler imaging reproducibility during exercise.

    Science.gov (United States)

    Bougault, V; Nottin, S; Noltin, S; Doucende, G; Obert, P

    2008-05-01

    Tissue Doppler imaging (TDI) is an echocardiographic technique used during exercising to improve the accuracy of a cardiovascular diagnostic. The validity of TDI requires its reproducibility, which has never been challenged during moderate to maximal intensity exercising. The present study was specifically designed to assess the transmitral Doppler and pulsed TDI reproducibility in 19 healthy men, who had undergone two identical semi-supine maximal exercise tests on a cycle ergometer. Systolic (S') and diastolic (E') tissue velocities at the septal and lateral walls as well as early transmitral velocities (E) were assessed during exercise up to maximal effort. The data were compared between the two tests at 40 %, 60 %, 80 % and 100 % of maximal aerobic power. Despite upper body movements and hyperventilation, good quality echocardiographic images were obtained in each case. Regardless of exercise intensity, no differences were noticed between the two tests for all measurements. The variation coefficients for Doppler variables ranged from 3 % to 9 % over the transition from rest to maximal exercise. The random measurement error was, on average, 5.8 cm/s for E' and 4.4 cm/s for S'. Overall, the reproducibility of TDI was acceptable. Tissue Doppler imaging can be used to accurately evaluate LV diastolic and/or systolic function for this range of exercise intensity.

  10. Doppler-ultralydundersøgelse af underekstremitetsarteriosklerose

    DEFF Research Database (Denmark)

    Rørdam, P; von Jessen, F; Sillesen, H H;

    1992-01-01

    Arteriography, which requires resources and is not entirely without risk, has hitherto been a prerequisite for reconstructive surgery in cases of symptom-producing arteriosclerosis in the lower limbs. As an alternative, indirect Doppler ultrasonic examination has been employed but does not appear...

  11. Power Doppler sonography of cervical lymphadenopathy

    Energy Technology Data Exchange (ETDEWEB)

    Ahuja, Anil; Ying, Michael; Yuen, Yuen Hok; Metreweli, Constantine

    2001-12-01

    AIMS: The supraclavicular region is a common site for tuberculous and metastatic nodes from infraclavicular carcinomas. Grey scale sonographic features differentiating the two have been previously described. However, as power Doppler sonography is now frequently used in the assessment of neck nodes, power Doppler features that may help to differentiate the two are discussed. MATERIALS AND METHODS: In 78 patients, power Doppler sonograms of nodes involved by metastases from infraclavicular carcinomas (n = 24) and tuberculosis (n = 54) were evaluated. The intranodal distribution of vessels and the intranodal vascular resistance of vessels was assessed and compared. In addition, the power Doppler features of metastatic nodes from infraclavicular carcinomas were compared with metastatic nodes from a head and neck primary (n = 38) such as nasopharyngeal carcinoma (NPC). RESULTS: Tuberculous nodes frequently demonstrated displaced hilar vascularity or avascularity and the intranodal vascular resistance was low. Metastatic nodes from infraclavicular primaries demonstrated capsular or mixed vascularity and their intranodal resistance was significantly (P < 0.05) higher. In general, metastatic nodes from infraclavicular primaries had a higher intranodal vascular resistance compared to metastatic nodes from NPC, but this was not statistically significant. CONCLUSION: In the supraclavicular region, the presence of displaced low resistance hilar vascularity or avascularity in nodes is suggestive of tuberculous nodes. Metastatic nodes from infraclavicular primaries have a capsular or mixed vascularity with high resistance. Ahuja, A. et al. (2001)

  12. Transcranial Doppler velocimetry in aneurysmal subarachnoid haemorrhage

    DEFF Research Database (Denmark)

    Staalsø, J M; Edsen, T; Romner, B

    2013-01-01

    -coded transcranial Doppler (TCCD), with the secondary aim of describing prediction of angiographic vasospasm and mortality. METHODS: /st>Sixty patients and 70 healthy controls were each examined in duplicate by alternating operators. A total of 939 measurements divided on 201 examination sets were conducted by four...

  13. Investigations of Near-Zone Doppler Effects.

    Science.gov (United States)

    Prouty, Dale Austen

    Far away from an electromagnetic source the normal Doppler shifts in frequency occur--a red shift for receding and a blue shift for approaching. As indicated by previous work with an infinitesimal dipole, different frequency shifts occur when the source and observer move closer together, into the near-zone. These "near-zone Doppler effects" are investigated for general sources and subsequently two specific examples are presented. The general results show that near-zone shifts are similar to far-zone shifts, but the local phase velocity must be used, i.e. (DIAGRAM, TABLE OR GRAPHIC OMITTED...PLEASE SEE DAI). In the far zone the phase velocity is the speed of light; in the near zone it differs. Fundamentally, the distance between surfaces of constant phase in the near zone is changed. The surfaces of constant phase for the waves are no longer spherical, but more ellipsoidal or spheroidal, so that a moving observer sees a different frequency shift. Two specific examples are presented to indicate the actual magnitude of near-zone effects. The examples include a prolate spheroidal antenna and a circular aperture. Once the magnitude of the effects is determined, the measurability of near-zone Doppler effects is discussed. The investigation concentrates on Fresnel zone effects due to the measurement problem. Finally, it is shown that for an electrically large wire antenna (the spheroidal example) near-zone Doppler effects are measurable.

  14. Spectroscopic observation of the rotational Doppler effect.

    Science.gov (United States)

    Barreiro, S; Tabosa, J W R; Failache, H; Lezama, A

    2006-09-15

    We report on the first spectroscopic observation of the rotational Doppler shift associated with light beams carrying orbital angular momentum. The effect is evidenced as the broadening of a Hanle electromagnetically induced transparency coherence resonance on Rb vapor when the two incident Laguerre-Gaussian laser beams have opposite topological charges. The observations closely agree with theoretical predictions.

  15. Method for Canceling Ionospheric Doppler Effect

    Science.gov (United States)

    Vessot, R. F. C.

    1982-01-01

    Unified transponder system with hydrogen-maser oscillators at both stations can compensate for both motional and ionospheric components of Doppler shift. Appropriate choices of frequency shift in output of mixer m3. System exploits proportionality between dispersive component of frequency shift and reciprocal of frequency to achieve cancellation of dispersive component at output.

  16. Calculating "g" from Acoustic Doppler Data

    Science.gov (United States)

    Torres, Sebastian; Gonzalez-Espada, Wilson J.

    2006-01-01

    Traditionally, the Doppler effect for sound is introduced in high school and college physics courses. Students calculate the perceived frequency for several scenarios relating a stationary or moving observer and a stationary or moving sound source. These calculations assume a constant velocity of the observer and/or source. Although seldom…

  17. [Phlegmasia alba dolens diagnosed with Doppler ultrasonography].

    Science.gov (United States)

    Wulff, C; Lorentzen, T; Christensen, E; Pedersen, E B

    1996-11-11

    Differential diagnostic problems may occur in a patient with a cold, pale and swollen leg. Especially when the peripheral blood pressure is reduced, it is particularly difficult to distinguish cases caused by venous thrombosis from those caused by arterial embolism. Colour-Doppler ultra-sonography might be helpful for establishing the correct diagnosis. A case history is presented.

  18. Doppler Shift Compensation Schemes in VANETs

    Directory of Open Access Journals (Sweden)

    F. Nyongesa

    2015-01-01

    Full Text Available Over the last decade vehicle-to-vehicle (V2V communication has received a lot of attention as it is a crucial issue in intravehicle communication as well as in Intelligent Transportation System (ITS. In ITS the focus is placed on integration of communication between mobile and fixed infrastructure to execute road safety as well as nonsafety information dissemination. The safety application such as emergence alerts lays emphasis on low-latency packet delivery rate (PDR, whereas multimedia and infotainment call for high data rates at low bit error rate (BER. The nonsafety information includes multimedia streaming for traffic information and infotainment applications such as playing audio content, utilizing navigation for driving, and accessing Internet. A lot of vehicular ad hoc network (VANET research has focused on specific areas including channel multiplexing, antenna diversity, and Doppler shift compensation schemes in an attempt to optimize BER performance. Despite this effort few surveys have been conducted to highlight the state-of-the-art collection on Doppler shift compensation schemes. Driven by this cause we survey some of the recent research activities in Doppler shift compensation schemes and highlight challenges and solutions as a stock-taking exercise. Moreover, we present open issues to be further investigated in order to address the challenges of Doppler shift in VANETs.

  19. On acceleration dependence of Doppler effect in light

    Indian Academy of Sciences (India)

    Sanjay M Wagh

    2013-09-01

    Using only the geometric relationships of suitable locations, we analyse Doppler effect in light to show how the acceleration of the source also contributes to the Doppler shift. We further propose that an experiment be performed using cyclotron-type devices to determine the acceleration dependence of the Doppler shift.

  20. Radar micro-doppler signatures processing and applications

    CERN Document Server

    Chen, Victor C; Miceli, William J

    2014-01-01

    Radar Micro-Doppler Signatures: Processing and applications concentrates on the processing and application of radar micro-Doppler signatures in real world situations, providing readers with a good working knowledge on a variety of applications of radar micro-Doppler signatures.

  1. Musculoskeletal colour/power Doppler in sports medicine

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, M; Langberg, Henning

    2010-01-01

    guidelines and recommendations are based on personal experience since no evidence in literature exists. The basic technical background of Doppler ultrasound and typical artefacts will be discussed, in order to understand and interpret the Doppler result. Recommendations for the Doppler settings are given...

  2. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550... system. (a) Identification. An ultrasonic pulsed doppler imaging system is a device that combines the features of continuous wave doppler-effect technology with pulsed-echo effect technology and is intended...

  3. Solid breast neoplasms: Differential diagnosis with pulsed Doppler ultrasound

    NARCIS (Netherlands)

    T.J.A. Kuijpers (T. J A); A.I.M. Obdeijn (Inge-Marie); Ph.M. Kruyt (Philip); M. Oudkerk (Matthijs)

    1994-01-01

    textabstractIn this prospective study, duplex Doppler ultrasound was used in 95 consecutive patients with solid breast masses to evaluate the presence of neovascular flow. A positive Doppler signal, i.e., a Doppler shift frequency of more than 1 kHz using a 5 MHz insonating frequency, was found in 3

  4. Classification of micro-Doppler signatures of human aquatic activity through simulation and measurement using transferred learning

    Science.gov (United States)

    Kim, Youngwook; Park, Jinhee; Moon, Taesup

    2017-05-01

    Remote detection of human aquatic activity can be applied not only to ocean surveillance but also to rescue operations. When a human is illuminated by electromagnetic waves, a Doppler signal is generated from his or her moving parts. Indeed, bodily movements are what make humans' micro-Doppler signatures unique, offering a chance to classify human motions. Certain studies have analyzed and attempted to recognize human aquatic activity, but the topic has yet to be extensively studied. In the present research, we simulate the micro-Doppler signatures of a swimming person in an attempt to investigate those signatures' characteristics. We model human arms as point scatterers while assuming a simple arm motion. By means of such a simulation, we can obtain spectrograms from a swimming person, then extend our measurement to multiple participants. Measurements are taken from five aquatic activities featuring five participants, comprising freestyle, backstroke, and breaststroke, pulling a boat, and rowing. As suggested by the simulation study, the spectrograms for the five activities show different micro-Doppler signatures; hence, we propose to classify them using a deep convolutional neural network (DCNN). In particular, we suggest the use of a transfer-learned DCNN, which is based on a DCNN pretrained by a large-scale RGB image dataset that is, ImageNet. The classification accuracy is calculated using fivefold cross-validation on our dataset. We find that a DCNN trained through transfer learning achieves the highest accuracy while also providing a significant performance boost over the conventional classification method.

  5. Youth Risk Behavior Surveillance System

    Science.gov (United States)

    ... Evaluation FAQs Additional Evaluation Resources Health & Academics Anti-Bullying Policies and Enumeration: An Infobrief for Local Education ... Youth Risk Behavior Surveillance System (YRBSS) monitors six types of health-risk behaviors that contribute to the ...

  6. Radioisotopic Thermoelectric Generator (RTG) Surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Mulford, Roberta Nancy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-29

    This lecture discusses stockpile stewardship efforts and the role surveillance plays in the process. Performance of the RTGs is described, and the question of the absence of anticipated He is addressed.

  7. Cyber surveillance for flood disasters

    National Research Council Canada - National Science Library

    Lo, Shi-Wei; Wu, Jyh-Horng; Lin, Fang-Pang; Hsu, Ching-Han

    2015-01-01

    ... river areas and sections. Therefore, in this paper, we propose an easy method to automatically monitor the flood object of a specific area, based on the currently widely used remote cyber surveillance systems and image...

  8. Airport Surveillance Radar : Model 8 -

    Data.gov (United States)

    Department of Transportation — The Airport Surveillance Radar Model 8 (ASR-8) is a short-range (60 nautical mile (nmi)), analog radar system used to detect and report the presence and location of...

  9. Airport Surveillance Radar : Model 7 -

    Data.gov (United States)

    Department of Transportation — The Airport Surveillance Radar Model 7 (ASR-7) is a short-range (60 nautical miles (nmi)) analog radar system used to detect and report the presence and location of...

  10. Surveillance of rotavirus diarrhea

    Directory of Open Access Journals (Sweden)

    Titis Widowati

    2012-01-01

    Full Text Available Background Rotavirus is a major cause of severe diarrhea and dehydration in children worldwide. Data on the burden of disease in Indonesia is limited. Objective To provide an epidemiological profile of rotavirus infection among children hospitalized for diarrhea in Mohammad Hoesin Hospital, Palembang. Methods In January - December 2006, a prospective, hospital-based surveillance was carried out in children aged less than five years, presenting with diarrhea. Stool samples were examined for rotavirus using enzyme immunoassay (EIA. G- and P-typing were performed on specimens confirmed to be positive by EIA. Results A total of 513 fecal specimens from 534 children were tested for rotavirus. Rotavirus was detected in 64% of the specimens, mostly of the G9 type (62.5%. Incidence of rotavirus diarrhea was highest in the 6 month to 2 years age group (60.4%. Children with rotavirus diarrhea were more likely to present with dehydration, compared to those with non-rotavirus diarrhea (94% vs 70%, respectively, P=0.03. Conclusion Rotavirus was the most common pathogen found in children with diarrhea. Rotavirus was detected in 64% of pediatric diarrheal specimens tested in our study. This finding warrants the use of a large-scale program to prevent disease, such as vaccination against rotavirus. [Paediatr Indones. 2012;52:22-7].

  11. Public Health Disease Surveillance Networks.

    Science.gov (United States)

    Morse, Stephen S

    2014-02-01

    Zoonotic infections are important sources of human disease; most known emerging infections are zoonotic (e.g., HIV, Ebola virus, severe acute respiratory syndrome, Nipah virus, and enteropathogenic Escherichia coli) and originated as natural infections of other species that acquired opportunities to come in contact with humans. There are also serious infectious diseases classically considered zoonotic, such as influenza, rabies, bubonic plague, brucellosis, and leptospirosis. More recently, it has been recognized that wildlife constitutes a particularly important source of novel zoonoses. With all this microbial movement, surveillance is considered the first line of public health defense. The zoonotic origin of many human and livestock infections argues strongly for the synergistic value of a One Health approach, which provides the capability to identify pathogens crossing into new species and could provide earlier warning of potential epidemics. This article discusses public health surveillance and major recent surveillance initiatives and reviews progress toward implementing a One Health surveillance framework. Networks discussed include global intergovernmental organizations and recent combined efforts of these organizations; Web-based nongovernmental systems (e.g., ProMED, the Program for Monitoring Emerging Diseases); and networks of bilateral or multilateral government programs (e.g., the CDC's Global Disease Detection [GDD] platform; the U.S. Department of Defense's Global Emerging Infections Surveillance and Response System [GEIS]; regional and subregional networks; and the U.S. Agency for International Development's Emerging Pandemic Threats [EPT] program and its surveillance component, PREDICT). Syndromic surveillance also has potential to complement existing systems. New technologies are enabling revolutionary capabilities for global surveillance, but in addition to serious technical needs, both sustainability and data-sharing mechanisms remain

  12. Development of the Observational Surveillance

    OpenAIRE

    Rieutort, Delphine

    2015-01-01

    Impact of population on the environment, and conversely, is obvious and represents a real challenge for Public Health since 2000. It has been shown an increase in cancer prevalence, respiratory disease or even reproductive disorders, for which multifactorial origins are strongly suspected. In this context, surveillance has become an essential tool to decision making in public health, and surveillance networks of health events are multiplying, giving rise to numerous databases (sometimes consi...

  13. Syndromic surveillance: A local perspective

    OpenAIRE

    2003-01-01

    The promise of syndromic surveillance extends beyond early warning for bioterrorist attacks. Even if bioterrorism is first detected by an astute clinician, syndromic surveillance can help delineate the size, location, and tempo of the epidemic or provide reassurance that a large outbreak is not occurring when a single case or a small, localized cluster of an unusual illness is detected. More broadly, however, as public health and medicine proceed in our information age, the use of existing el...

  14. Occupational Surveillance for Spaceflight Exposures

    Science.gov (United States)

    Tarver, William J.

    2010-01-01

    This slide presentation reviews the importance of longterm occupational health surveillance of astronauts after exposure to the possible hazards of spaceflight. Because there is not much information about long term effects of spaceflight on human health, it is important to identify some of the possible results of exposure to the many possible factors that can influence longterm health impacts. This surveillance also allows for NASA to meet the obligation to care for the astronauts for their lifetime.

  15. Surface Environmental Surveillance Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    RW Hanf; TM Poston

    2000-09-20

    Environmental surveillance data are used in assessing the impact of current and past site operations on human health and the environment, demonstrating compliance with applicable local, state, and federal environmental regulations, and verifying the adequacy of containment and effluent controls. SESP sampling schedules are reviewed, revised, and published each calendar year in the Hanford Site Environmental Surveillance Master Sampling Schedule. Environmental samples are collected by SESP staff in accordance with the approved sample collection procedures documented in this manual.

  16. Rubidium atomic line filtered (RALF) Doppler velocimetry

    Science.gov (United States)

    Fajardo, Mario E.; Molek, Christopher D.; Vesely, Annamaria L.

    2017-01-01

    We report recent improvements to our Rubidium Atomic Line Filtered (RALF) Doppler velocimetry apparatus [M.E. Fajardo, C.D. Molek, and A.L. Vesely, J. Appl. Phys. 118, 144901 (2015)]. RALF is a high-velocity and high-acceleration adaptation of the Doppler Global Velocimetry method for measuring multi-dimensional velocity vector flow fields, which was developed in the 1990s by aerodynamics researchers [H. Komine, U.S. Patent #4,919,536]. Laser velocimetry techniques in common use within the shock physics community (e.g. VISAR, Fabry-Pérot, PDV) decode the Doppler shift of light reflected from a moving surface via interference phenomena. In contrast, RALF employs a completely different physical principle: the frequency-dependent near-resonant optical transmission of a Rb/N2 gas cell, to encode the Doppler shift of reflected λ0 ≈ 780.24 nm light directly onto the transmitted light intensity. Thus, RALF is insensitive to minor changes to the optical pathlengths and transit times of the Doppler shifted light, which promises a number of practical advantages in imaging velocimetry applications. The single-point RALF proof-of-concept apparatus described here is fiber optic based, and our most recent modifications include the incorporation of a larger bandwidth detection system, and a second 780 nm laser for simultaneous upshifted-PDV (UPDV) measurements. We report results for the laser driven launch of a 10-μm-thick aluminum flyer which show good agreement between the RALF and UPDV velocity profiles, within the limitations of the admittedly poor signal:noise ratio (SNR) RALF data.

  17. A MAGNETIC CALIBRATION OF PHOTOSPHERIC DOPPLER VELOCITIES

    Energy Technology Data Exchange (ETDEWEB)

    Welsch, Brian T.; Fisher, George H. [Space Sciences Laboratory, University of California, Berkeley, CA 94720-7450 (United States); Sun, Xudong [W. W. Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA 94305 (United States)

    2013-03-10

    The zero point of measured photospheric Doppler shifts is uncertain for at least two reasons: instrumental variations (from, e.g., thermal drifts); and the convective blueshift, a known correlation between intensity and upflows. Accurate knowledge of the zero point is, however, useful for (1) improving estimates of the Poynting flux of magnetic energy across the photosphere, and (2) constraining processes underlying flux cancellation, the mutual apparent loss of magnetic flux in closely spaced, opposite-polarity magnetogram features. We present a method to absolutely calibrate line-of-sight (LOS) velocities in solar active regions (ARs) near disk center using three successive vector magnetograms and one Dopplergram coincident with the central magnetogram. It exploits the fact that Doppler shifts measured along polarity inversion lines (PILs) of the LOS magnetic field determine one component of the velocity perpendicular to the magnetic field, and optimizes consistency between changes in LOS flux near PILs and the transport of transverse magnetic flux by LOS velocities, assuming that ideal electric fields govern the magnetic evolution. Previous calibrations fitted the center-to-limb variation of Doppler velocities, but this approach cannot, by itself, account for residual convective shifts at the limb. We apply our method to vector magnetograms of AR 11158, observed by the Helioseismic and Magnetic Imager aboard the Solar Dynamics Observatory, and find clear evidence of offsets in the Doppler zero point in the range of 50-550 m s{sup -1}. In addition, we note that a simpler calibration can be determined from an LOS magnetogram and Dopplergram pair from the median Doppler velocity among all near-disk-center PIL pixels. We briefly discuss shortcomings in our initial implementation, and suggest ways to address these. In addition, as a step in our data reduction, we discuss the use of temporal continuity in the transverse magnetic field direction to correct apparently

  18. Classification of ground moving targets using bicepstrum-based features extracted from Micro-Doppler radar signatures

    Science.gov (United States)

    Molchanov, Pavlo O.; Astola, Jaakko T.; Egiazarian, Karen O.; Totsky, Alexander V.

    2013-12-01

    In this article, a novel bicepstrum-based approach is suggested for ground moving radar target classification. Distinctive classification features were extracted from short-time backscattering bispectrum estimates of the micro-Doppler signature. Real radar data were obtained using surveillance Doppler microwave radar operating at 34 GHz. Classifier performance was studied in detail using the Gaussian Mixture Mode and Maximum Likelihood decision making rule, and the results were verified on a multilayer perceptron and Support Vector Machine. Experimental real radar measurements demonstrated that it is quite feasible to discern three classes of humans (single, two and three persons) walking in a vegetation cluttered environment using proposed bicepstrum-based classification features. Sophisticated bispectrum-based signal processing provides the extraction of new classification features in the form of phase relationships in the radar data. It provides a novel insight into moving radar target classification compared to the commonly used energy-based strategy.

  19. Practicability of intraoperative microvascular Doppler sonography in aneurysm surgery.

    Science.gov (United States)

    Firsching, R; Synowitz, H J; Hanebeck, J

    2000-09-01

    Inadvertent narrowing of parent or branching vessels is one major cause of unfavorable outcome from aneurysm surgery. Intraoperative micro-Doppler sonography of arterial brain vessels during surgery for cerebral aneurysms of the anterior circulation was performed in 50 patients and compared retrospectively with 50 patients, who were operated upon without micro-Doppler sonography. Intraoperative micro-Doppler sonography demonstrated the need for repositioning of the clip in 12 instances. Outcome after surgery with micro-Doppler sonography appeared slightly better than without. Micro-Doppler sonography is concluded to be a practicable adjunct to routine aneurysm surgery.

  20. Exact classical Doppler effect derived from the photon emission process

    CERN Document Server

    Lin, Chyi-Lung; Hsieh, Shang-Lin; Tsai, Chun-Ming

    2016-01-01

    The concept of photon is not necessary only applied to the relativistic Doppler theory. It may also work well for classical theory. As conservation of momentum and energy are physical laws, if applying these laws gives the exact relativistic Doppler effect, it should also give the exact classical Doppler effect. So far the classical Doppler effect is only obtained by using some approximation, as derived by Fermi in 1932. We show that the exact classical Doppler effect can be derived from the photon emission process in the exact treatment and reveal that these results are the same as those derived from the wave theory of light.

  1. ESTIMATION OF DOPPLER CENTROID FREQUENCY IN SPACEBORNE SCANSAR

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    Doppler centroid frequency is an essential parameter in the imaging processing of the Scanning mode Synthetic Aperture Radar(ScanSAR).Inaccurate Doppler centroid frequency will result in ghost images in imaging result.In this letter,the principle and algorithms of Doppler centroid frequency estimation are introduced.Then the echo data of ScanSAR system is analyzed.Based on the algorithms of energy balancing and correlation Doppler estimator in the estimation of Doppler centroid fequency in strip mode SAR,an improved method for Doppler centroid frequency estimation in ScanSAR is proposed.The method has improved the accuracy of Doppler centroid fequency estimation in ScanSAR by zero padding between burst data.Finally,the proposed method is validated with the processing of ENVironment SATellite Advanced Synthetic Aperture Radar(ENVISAT ASAR)wide swath raw data.

  2. Power and color Doppler ultrasound settings for inflammatory flow

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin

    2015-01-01

    OBJECTIVE: To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. METHODS: Six different types of ultrasound machines were used....... On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA......) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. RESULTS...

  3. Superharmonic microbubble Doppler effect in ultrasound therapy

    Science.gov (United States)

    Pouliopoulos, Antonios N.; Choi, James J.

    2016-08-01

    The introduction of microbubbles in focused ultrasound therapies has enabled a diverse range of non-invasive technologies: sonoporation to deliver drugs into cells, sonothrombolysis to dissolve blood clots, and blood-brain barrier opening to deliver drugs into the brain. Current methods for passively monitoring the microbubble dynamics responsible for these therapeutic effects can identify the cavitation position by passive acoustic mapping and cavitation mode by spectral analysis. Here, we introduce a new feature that can be monitored: microbubble effective velocity. Previous studies have shown that echoes from short imaging pulses had a Doppler shift that was produced by the movement of microbubbles. Therapeutic pulses are longer (>1 000 cycles) and thus produce a larger alteration of microbubble distribution due to primary and secondary acoustic radiation force effects which cannot be monitored using pulse-echo techniques. In our experiments, we captured and analyzed the Doppler shift during long therapeutic pulses using a passive cavitation detector. A population of microbubbles (5  ×  104-5  ×  107 microbubbles ml-1) was embedded in a vessel (inner diameter: 4 mm) and sonicated using a 0.5 MHz focused ultrasound transducer (peak-rarefactional pressure: 75-366 kPa, pulse length: 50 000 cycles or 100 ms) within a water tank. Microbubble acoustic emissions were captured with a coaxially aligned 7.5 MHz passive cavitation detector and spectrally analyzed to measure the Doppler shift for multiple harmonics above the 10th harmonic (i.e. superharmonics). A Doppler shift was observed on the order of tens of kHz with respect to the primary superharmonic peak and is due to the axial movement of the microbubbles. The position, amplitude and width of the Doppler peaks depended on the acoustic pressure and the microbubble concentration. Higher pressures increased the effective velocity of the microbubbles up to 3 m s-1, prior to the onset of

  4. Congenital syphilis surveillance

    Directory of Open Access Journals (Sweden)

    Antonella Marangoni

    2011-06-01

    Full Text Available Congenital syphilis (CS is mainly a consequence of the lack of antenatal care and control of sexually transmitted infections.The bedrock of the prevention of CS is syphilis diagnosis by serological screening during pregnancy.Current Italian guidelines suggest that all the pregnant women should be tested in the first trimester. Due to the frequently absence of specific signs of infection at birth, laboratory tests are often the only method for a correct CS diagnosis. The aim of this study was to evaluate the usefulness of Treponema pallidum IgM Western Blot (WB and Polymerase Chain Reaction (PCR on cerebrospinal fluid (CSF as an aid in the diagnosis of CS during a prospective surveillance study carried out at St. Orsola Hospital in Bologna, Italy, from November 2000 through June 2010. All pregnant women during pregnancy and at delivery were screened for syphilis by ARCHITECT® Syphilis TP, Abbott. Positive samples were further analysed by Treponema Pallidum Hemagglutination Test (TPHA and Rapid Plasma Reagin (RPR tests, Radim.An in-house Western Blot (WB was also performed. Infants born to syphilis seropositive mothers were enrolled in a prospective follow up. At birth, tests were performed (including IgM WB. Infants with positive RPR tests at birth born to mothers not adequately treated received also a long bone radiograph as well as a complete CSF analysis, including Veneral Disease Research Laboratori (VDRL (Siemens Healthcare Diagnostics and PCR testing. All seroreactive infants received careful follow up examinations and serological testing at 0, 3, 6, 9, 12 months or until the tests became negative. In this study, positive syphilis serology was noted in 151 pregnant women delivering in our hospital. Fifteen women had never been adequately treated, and 9 out 15 gave birth to infected newborns.All these 9 infants had positive IgM WB results on serum samples. Two babies had characteristic long bone lesions at X-ray examination and 3 were born

  5. Color Doppler US of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Bertolotto, Michele (ed.) [Trieste Univ. Ospedale di Cattinara (Italy). Dept. Radiology

    2008-07-01

    This book provides a comprehensive reference and practical guide on the application of US to penile diseases and conditions. After introductory chapters on technical requirements and penile anatomy, subsequent chapters offer a systematic overview of the diverse applications of color Doppler US. The topics covered include erectile dysfunction, Peyronie's disease, priapism, trauma, tumors, the postoperative penis, inflammation, and fibrosis. Each topic is introduced by a clinical overview with the purpose of clarifying the problems and elucidating what the urologist may expect from color Doppler US. Thereafter, performance of the US study is explained and the pathological anatomy reviewed. High-quality images obtained with high-end US equipment are included. Each chapter also contains a section on the diagnostic information provided by other imaging modalities, and in particular MRI. (orig.)

  6. Renal duplex Doppler ultrasound findings in diabetics

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Hyang Yee; Kim, Young Geun; Kook, Cheol Keu; Yoon, Chong Hyun; Lee, Shin Hyung; Lee, Chang Joon [National Medical Center, Seoul (Korea, Republic of)

    1993-12-15

    The correlation between clinical-laboratory findings and renal duplex Doppler ultrasound findings was studied in 45 patients with diabetes mellitus to see the role of duplex Doppler ultrasound in the detection of diabetic nephropathy. The resistive indices in patients with elevated serum creatinine, BUN, proteinuria, and systolic blood pressure levels were statistically significantly higher than those in patients with normal levels (p<0.05). Also resistive indics in patients with retinopathy were higher than that in patients without retinopathy (p<0.05). But the ultrasound morphologic changes of kidney such as renal length, cortical eye-catching, and corticomedullarycontrast were not well correlated with clinical-laboratory data and resistive index. The resistive index of the kidney in conjunction with clinical-laboratory data in diabetics may be helpful in the evaluation of diabetic nephropathy

  7. [Color-Doppler semiology in transplanted kidney].

    Science.gov (United States)

    Rivolta, R; Castagnone, D; Burdick, L; Mandelli, C; Mangiarotti, R

    1993-05-01

    Color-encoded duplex ultrasonography (CEDU) makes a more accurate technique in kidney graft monitoring by combining real-time US with pulsed Doppler studies of renal vasculature. It is a non-invasive and easy technique. Suitable to study the whole renal artery and vein, CEDU also allows the qualitative and quantitative assessment of the intrarenal vasculature and therefore the easy diagnosis of such vessel dysfunctions as arteriovenous fistulas following biopsy. Moreover, Doppler spectral analysis can be used to distinguish among different causes of renal allograft dysfunction--i.e. rejection, cyclosporine nephrotoxicity or acute tubular necrosis. The value of the resistive index for the differential diagnosis is discussed. CEDU allows a more reliable measurement of renal blood flow thanks to the more precise evaluation of renal artery diameter and mean flow velocity.

  8. Transcranial Doppler sonography in familial hemiplegic migraine

    Energy Technology Data Exchange (ETDEWEB)

    Pierelli, F.; Pauri, F.; Cupini, L.M.; Fiermonte, G.; Rizzo, P.A. (Universita la Sapienza, Roma (Italy))

    1991-02-01

    A patient affected by familial hemiplegic migraine underwent transcranial Doppler sonography twice: the first during a spontaneous attack with right hemiparesis and aphasia, the second during a headachefree period. During the attack the following haemodynamic changes were seen: (a) bilateral increase in the middle cerebral artery and anterior cerebral artery blood flow velocities (this increase was more pronounced on the left side), (b) decreased systo-diastolic ratio and pulsatility index on the right side, (c) increased systo-diastolic ratio and pulsatility index on the left side. The results indicate that during the attack in this familial hemiplegic migraine patient, a diffuse vasoconstriction of the basal cerebral arteries developed. Moreover, transcranial Doppler sonography data suggest that a prolonged vasoconstriction of the peripheral arterioles could play a role in determining the neurological symptoms in this syndrome. 13 refs., 1 figs., 1 tab.

  9. Doppler Lidar Wind Value-Added Product

    Energy Technology Data Exchange (ETDEWEB)

    Newsom, R. K. [DOE ARM Climate Research Facility, Washington, DC (United States); Sivaraman, C. [DOE ARM Climate Research Facility, Washington, DC (United States); Shippert, T. R. [DOE ARM Climate Research Facility, Washington, DC (United States); Riihimaki, L. D. [DOE ARM Climate Research Facility, Washington, DC (United States)

    2015-07-01

    Wind speed and direction, together with pressure, temperature, and relative humidity, are the most fundamental atmospheric state parameters. Accurate measurement of these parameters is crucial for numerical weather prediction. Vertically resolved wind measurements in the atmospheric boundary layer are particularly important for modeling pollutant and aerosol transport. Raw data from a scanning coherent Doppler lidar system can be processed to generate accurate height-resolved measurements of wind speed and direction in the atmospheric boundary layer.

  10. Colour Doppler ultrasound of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Wilkins, C.J.; Sriprasad, S.; Sidhu, P.S. E-mail: paulsidhu@compuserve.com

    2003-07-01

    Because it is a superficial structure, the penis is ideally suited to ultrasound imaging. A number of disease processes, including Peyronie's disease, penile fractures and penile tumours, are clearly visualized with ultrasound. An assessment of priapism can also be made using spectral Doppler waveform technology. Furthermore, dynamic assessment of cavernosal arterial changes after pharmaco-stimulation allows diagnosis of arterial and venogenic causes for impotence. This pictorial review illustrates the range of diseases encountered with ultrasound of the penis.

  11. Precise Doppler Monitoring of Barnard's Star

    CERN Document Server

    Choi, Jieun; Marcy, Geoffrey W; Howard, Andrew W; Fischer, Debra A; Johnson, John A; Isaacson, Howard; Wright, Jason T

    2012-01-01

    We present 248 precise Doppler measurements of Barnard's Star (Gl 699), the second nearest star system to Earth, obtained from Lick and Keck Observatories during 25 years between 1987 and 2012. The early precision was 20 \\ms{} but was 2 \\ms{} during the last 8 years, constituting the most extensive and sensitive search for Doppler signatures of planets around this stellar neighbor. We carefully analyze the 136 Keck radial velocities spanning 8 years by first applying a periodogram analysis to search for nearly circular orbits. We find no significant periodic Doppler signals with amplitudes above $\\sim$2 \\ms{}, setting firm upper limits on the minimum mass (\\msini) of any planets with orbital periods from 0.1 to 1000 days. Using a Monte Carlo analysis for circular orbits, we determine that planetary companions to Barnard's Star with masses above 2 \\mearth{} and periods below 10 days would have been detected. Planets with periods up to 2 years and masses above 10 \\mearth{} (0.03 \\mjup) are also ruled out. A sim...

  12. Doppler Lidar for Wind Measurements on Venus

    Science.gov (United States)

    Singh, Upendra N.; Emmitt, George D.; Yu, Jirong; Kavaya, Michael J.

    2010-01-01

    NASA Langley Research Center has a long history of developing 2-micron laser transmitter for wind sensing. With support from NASA Laser Risk Reduction Program (LRRP) and Instrument Incubator Program (IIP), NASA Langley Research Center has developed a state-of-the-art compact lidar transceiver for a pulsed coherent Doppler lidar system for wind measurement. The transmitter portion of the transceiver employs the high-pulse-energy, Ho:Tm:LuLiF, partially conductively cooled laser technology developed at NASA Langley. The transceiver is capable of 250 mJ pulses at 10 Hz. It is very similar to the technology envisioned for coherent Doppler lidar wind measurements from Earth and Mars orbit. The transceiver is coupled to the large optics and data acquisition system in the NASA Langley VALIDAR mobile trailer. The large optics consists of a 15-cm off-axis beam expanding telescope, and a full-hemispheric scanner. Vertical and horizontal vector winds are measured, as well as relative backscatter. The data acquisition system employs frequency domain velocity estimation and pulse accumulation. It permits real-time display of the processed winds and archival of all data. This lidar system was recently deployed at Howard University facility in Beltsville, Mary-land, along with other wind lidar systems. Coherent Doppler wind lidar ground-based wind measurements and comparisons with other sensors will be presented. A simulation and data product for wind measurement at Venus will be presented.

  13. Privacy Implications of Surveillance Systems

    DEFF Research Database (Denmark)

    Thommesen, Jacob; Andersen, Henning Boje

    2009-01-01

    This paper presents a model for assessing the privacy „cost‟ of a surveillance system. Surveillance systems collect and provide personal information or observations of people by means of surveillance technologies such as databases, video or location tracking. Such systems can be designed...... by analyzing a location-based system for airport passengers developed for a Copenhagen Airport, and the dimensions are used to explain user reactions to different services offered by the system....... for various purposes, even as a service for those being observed, but in any case they will to some degree invade their privacy. The model provided here can indicate how invasive any particular system may be – and be used to compare the invasiveness of different systems. Applying a functional approach...

  14. Informatics enables public health surveillance

    Directory of Open Access Journals (Sweden)

    Scott J. N McNabb

    2017-01-01

    Full Text Available Over the past decade, the world has radically changed. New advances in information and communication technologies (ICT connect the world in ways never imagined. Public health informatics (PHI leveraged for public health surveillance (PHS, can enable, enhance, and empower essential PHS functions (i.e., detection, reporting, confirmation, analyses, feedback, response. However, the tail doesn't wag the dog; as such, ICT cannot (should not drive public health surveillance strengthening. Rather, ICT can serve PHS to more effectively empower core functions. In this review, we explore promising ICT trends for prevention, detection, and response, laboratory reporting, push notification, analytics, predictive surveillance, and using new data sources, while recognizing that it is the people, politics, and policies that most challenge progress for implementation of solutions.

  15. UTERINE ARTERY DOPPLER STUDY FOR PREDICTION OF ADVERSE OUTCOME IN HIGH RISK PREGNANCY

    Directory of Open Access Journals (Sweden)

    Gunjan

    2015-07-01

    Full Text Available AIM : To detect abnormal waveforms in uterine artery in pregnancies at risk between 20 to 24 weeks of gestation and to measure Resistance index (RI and systolic/diastolic ratio(S/D of these waveforms in study population and to study correlation of Doppler dat a with adverse pregnancy outcome. METHODS : This is a prospective study included Doppler analysis of uterine artery waveforms in 107 normotensive women with singleton pregnancy between 20 to24 weeks of period of gestation who were considered to be at increa sed risk of developing pregnancy complications. Women with Multiple gestation, with congenital anomaly of fetus, chronic hypertension, renal disease, cardiac disease, Diabetes Mellitus were excluded from the study. Bilateral uterine artery Doppler was done and Parameters studied were S/D ratio and RI in uterine artery. Early diastolic notch in uterine artery was watched for. The flow velocity waveforms considered abnormal if there was an early diastolic notch in uterine artery in either right or left uterin e artery was watched for abnormal pregnancy outcomes considered are Gestational hypertension, Pre - eclampsia IUGR, Abruptio placentae, IUD and preterm deliveries. RESULTS : minimum women were aged 21 – 25 year with minimum of 18 years and maximum of 36 years, 28% were primigravidae while 72% were multigravidae mean gestational age of which scan was done was 22 wks 1 day (20 - 24 minimum gestational age at time of delivery was 28 wks of gestation 70% women were delivered vaginally and 30% LSCS. 7% women developed Gestational Hypertension, 5% developed Preeclampsia, 8% neonates with IUGR, 3% developed Placental Abruption while 4% had IUD and 8% had Preterm deliveries. CONCLUSION : Abnormal uterine artery Doppler studies in second trimester have been associated with subsequent adverse pregnancy out comes including Preeclampsia IUGR and perinatal mortality. Doppler velocimetry is a primary tool for fetomaternal surveillance in high

  16. Doppler effect in resonant photoemission from SF6: correlation between Doppler profile and Auger emission anisotropy.

    Science.gov (United States)

    Kitajima, M; Ueda, K; De Fanis, A; Furuta, T; Shindo, H; Tanaka, H; Okada, K; Feifel, R; Sorensen, S L; Gel'mukhanov, F; Baev, A; Agren, H

    2003-11-21

    Fragmentation of the SF6 molecule upon F 1s excitation has been studied by resonant photoemission. The F atomiclike Auger line exhibits the characteristic Doppler profile that depends on the direction of the photoelectron momentum relative to the polarization vector of the radiation as well as on the photon energy. The measured Doppler profiles are analyzed by the model simulation that takes account of the anisotropy of the Auger emission in the molecular frame. The Auger anisotropy extracted from the data decreases with an increase in the F-SF5 internuclear distance.

  17. National Cardiac Device Surveillance Program Database

    Data.gov (United States)

    Department of Veterans Affairs — The National Cardiac Device Surveillance Program Database supports the Eastern Pacemaker Surveillance Center (EPSC) staff in its function of monitoring some 11,000...

  18. Inappropriate colonoscopic surveillance of hyperplastic polyps.

    LENUS (Irish Health Repository)

    Keane, R A

    2011-11-15

    Colonoscopic surveillance of hyperplastic polyps alone is controversial and may be inappropriate. The colonoscopy surveillance register at a university teaching hospital was audited to determine the extent of such hyperplastic polyp surveillance. The surveillance endoscopy records were reviewed, those patients with hyperplastic polyps were identified, their clinical records were examined and contact was made with each patient. Of the 483 patients undergoing surveillance for colonic polyps 113 (23%) had hyperplastic polyps alone on last colonoscopy. 104 patients remained after exclusion of those under appropriate surveillance. 87 of the 104 patients (84%) were successfully contacted. 37 patients (8%) were under appropriate colonoscopic surveillance for a significant family history of colorectal carcinoma. 50 (10%) patients with hyperplastic polyps alone and no other clinical indication for colonoscopic surveillance were booked for follow up colonoscopy. This represents not only a budgetary but more importantly a clinical opportunity cost the removal of which could liberate valuable colonoscopy time for more appropriate indications.

  19. Regional Disease Surveillance Meeting - Final Paper

    Energy Technology Data Exchange (ETDEWEB)

    Lesperance, Ann M.; Mahy, Heidi A.

    2006-08-08

    On June 1, 2006, public health officials working in surveillance, epidemiological modeling, and information technology communities from the Seattle/Tacoma area and State of Washington met with members of the Pacific Northwest National Laboratory (PNNL) to discuss the current state of disease surveillance and gaps and needs to improve the current systems. The meeting also included a discussion of PNNL initiatives that might be appropriate to enhance disease surveillance and the current tools being used for disease surveillance. Participants broke out into two groups to identify critical gaps and needs for improving a surveillance system, and discuss the requirements for developing improved surveillance. Each group developed a list of key priorities summarizing the requirements for improved surveillance. The objective of this meeting was to work towards the development of an improved disease surveillance system.

  20. Surveillance intervals for small abdominal aortic aneurysms

    DEFF Research Database (Denmark)

    Bown, Matthew J; Sweeting, Michael J; Brown, Louise C

    2013-01-01

    Small abdominal aortic aneurysms (AAAs [3.0 cm-5.4 cm in diameter]) are monitored by ultrasound surveillance. The intervals between surveillance scans should be chosen to detect an expanding aneurysm prior to rupture.......Small abdominal aortic aneurysms (AAAs [3.0 cm-5.4 cm in diameter]) are monitored by ultrasound surveillance. The intervals between surveillance scans should be chosen to detect an expanding aneurysm prior to rupture....

  1. Doppler-compensated three-photon electromagnetically induced transparency

    CERN Document Server

    Carr, Christopher; Sargsyan, Armen; Sarkisyan, David; Adams, Charles S; Weatherill, Kevin J

    2012-01-01

    We demonstrate Doppler-compensated bright and dark states in a resonant four-level atomic system. The spectral features are the result of electromagnetically induced transparency (EIT) and absorption (EIA) and are sub-Doppler due to the compensation of Doppler shifts with AC Stark shifts. We demonstrate the effect using a three-photon cascade system to Rydberg states in Cs vapor, however, the results apply to any four-level cascade or N-type system.

  2. Influence of Doppler Bin Width on GNSS Detection Probabilities

    CERN Document Server

    Geiger, Bernhard C

    2011-01-01

    The acquisition stage in GNSS receivers determines Doppler shifts and code phases of visible satellites. Acquisition is thus a search in two continuous dimensions, where the digital algorithms require a partitioning of the search space into cells. We present analytic expressions for the acquisition performance depending on the partitioning of the Doppler frequency domain. In particular, the impact of the number and width of Doppler bins is analyzed. The presented results are verified by simulations.

  3. New insights from inside-out Doppler tomography

    CERN Document Server

    Kotze, Enrico J

    2015-01-01

    We present preliminary results from our investigation into using an 'inside-out' velocity space for creating a Doppler tomogram. The aim is to transpose the inverted appearance of the Cartesian velocity space used in normal Doppler tomography. In a comparison between normal and inside-out Doppler tomograms of cataclysmic variables, we show that the inside-out velocity space has the potential to produce new insights into the accretion dynamics in these systems.

  4. Analysis on rotational Doppler Effect based on modal expansion method

    CERN Document Server

    Zhou, Hailong; Zhang, Pei; Zhang, Xinliang

    2015-01-01

    We theoretically investigate the optical rotational Doppler Effect using modal expansion method. We find that the frequency shift content is only determined by the surface of spinning object and the reduced Doppler shift is linear to the change of mode index. The theoretical model makes us better understand the physical processes of rotational Doppler Effect. It can provide theoretical guidance for many related applications, such as detection of rotating bodies, detection of OAM and frequency shift.

  5. Range-instantaneous Doppler imaging of inverse synthetic aperture sonar

    Institute of Scientific and Technical Information of China (English)

    XU Jia; JIANG Xingzhou; TANG Jingsong

    2003-01-01

    Because the existing range-Doppler algorithm in inverse synthetic aperture sonar (ISAS) is based on target model of uniform motion, it may be invalidated for maneuvering targets due to the time-varying changes of both individual scatter′s Doppler and imaging projection plane. To resolve the problem, a new range-instantaneous Doppler imaging method is proposed for imaging maneuvering targets based on time-frequency analysis. The proposed approach is verified using real underwater acoustic data.

  6. Anomaly detection for internet surveillance

    NARCIS (Netherlands)

    Bouma, H.; Raaijmakers, S.A.; Halma, A.H.R.; Wedemeijer, H.

    2012-01-01

    Many threats in the real world can be related to activity of persons on the internet. Internet surveillance aims to predict and prevent attacks and to assist in finding suspects based on information from the web. However, the amount of data on the internet rapidly increases and it is time consuming

  7. Video Surveillance using Distance Maps

    NARCIS (Netherlands)

    Schouten, Theo E.; Kuppens, Harco C.; Broek, van den Egon L.; Kehtarnavaz, Nasser; Laplante, Phillip A.

    2006-01-01

    Human vigilance is limited; hence, automatic motion and distance detection is one of the central issues in video surveillance. Hereby, many aspects are of importance, this paper specially addresses: efficiency, achieving real-time performance, accuracy, and robustness against various noise factors.

  8. Video surveillance with speckle imaging

    Science.gov (United States)

    Carrano, Carmen J.; Brase, James M.

    2007-07-17

    A surveillance system looks through the atmosphere along a horizontal or slant path. Turbulence along the path causes blurring. The blurring is corrected by speckle processing short exposure images recorded with a camera. The exposures are short enough to effectively freeze the atmospheric turbulence. Speckle processing is used to recover a better quality image of the scene.

  9. Anomaly detection for internet surveillance

    NARCIS (Netherlands)

    Bouma, H.; Raaijmakers, S.A.; Halma, A.H.R.; Wedemeijer, H.

    2012-01-01

    Many threats in the real world can be related to activity of persons on the internet. Internet surveillance aims to predict and prevent attacks and to assist in finding suspects based on information from the web. However, the amount of data on the internet rapidly increases and it is time consuming

  10. Smart sensing surveillance video system

    Science.gov (United States)

    Hsu, Charles; Szu, Harold

    2016-05-01

    An intelligent video surveillance system is able to detect and identify abnormal and alarming situations by analyzing object movement. The Smart Sensing Surveillance Video (S3V) System is proposed to minimize video processing and transmission, thus allowing a fixed number of cameras to be connected on the system, and making it suitable for its applications in remote battlefield, tactical, and civilian applications including border surveillance, special force operations, airfield protection, perimeter and building protection, and etc. The S3V System would be more effective if equipped with visual understanding capabilities to detect, analyze, and recognize objects, track motions, and predict intentions. In addition, alarm detection is performed on the basis of parameters of the moving objects and their trajectories, and is performed using semantic reasoning and ontologies. The S3V System capabilities and technologies have great potential for both military and civilian applications, enabling highly effective security support tools for improving surveillance activities in densely crowded environments. It would be directly applicable to solutions for emergency response personnel, law enforcement, and other homeland security missions, as well as in applications requiring the interoperation of sensor networks with handheld or body-worn interface devices.

  11. Video surveillance using distance maps

    NARCIS (Netherlands)

    Schouten, Theo E.; Kuppens, Harco C.; van den Broek, Egon; Kehtarnavaz, Nasser; Laplante, Phillip A,

    2006-01-01

    Human vigilance is limited; hence, automatic motion and distance detection is one of the central issues in video surveillance. Hereby, many aspects are of importance, this paper specially addresses: efficiency, achieving real-time performance, accuracy, and robustness against various noise factors.

  12. Micro-doppler radar classification of human motions under various training scenarios

    Science.gov (United States)

    Fairchild, Dustin P.; Narayanan, Ram M.

    2013-05-01

    The identification and classification of human motions has become a popular area of research due to its broad range of applications. Knowledge of a person's movements can be a useful tool in surveillance, security, military combat, search and rescue operations, and the medical fields. Classification of common stationary human movements has been performed under various scenarios for two different micro-Doppler radar systems: S-band radar and millimeter-wave (mm-wave) radar. Each radar system has been designed for a specific scenario. The S-band radar is intended for through-the-wall situations at close distances, whereas the mm-wave radar is designed for long distance applications and also for through light foliage. Here, the performance of these radars for different training scenarios is investigated. The S-band radar will be analyzed for classification without a wall barrier, through a brick wall, and also through a cinder block wall. The effect of a wall barrier on micro-Doppler signatures will be briefly discussed. The mm-wave radar will be analyzed for classification at distances of 30, 60, and 91 meters.

  13. Video Surveillance: Privacy Issues and Legal Compliance

    DEFF Research Database (Denmark)

    Mahmood Rajpoot, Qasim; Jensen, Christian D.

    2015-01-01

    . There is a need to balance the usage of video surveillance against its negative impact on privacy. This chapter aims to highlight the privacy issues in video surveillance and provides a model to help identify the privacy requirements in a video surveillance system. The authors make a step in the direction...

  14. Evaluating Peripheral Vascular Injuries: Is Color Doppler Enough for Diagnosis?

    Directory of Open Access Journals (Sweden)

    Mohd Lateef Wani

    2014-03-01

    Full Text Available Background:: Vascular injury poses a serious threat to limb and life. Thus, diagnosis should be made immediately with minimally invasive methods. Doppler is a good aid in diagnosis of vascular injury. Methods:: The present prospective study was conducted on 150 patients who presented with soft signs (the signs which are suggestive but not confirmatory of vascular injury. They were subjected to color Doppler examination before exploration. The patients with the features of vascular injury on color Doppler were subjected to exploration. On the other hand, those who had normal Doppler were subjected to CT- angiography. Then, the findings of the exploration were matched with those of color Doppler. The data were analyzed using the SPSS statistical software. Results:: Out of the 150 Doppler examinations, 110 (73.33% were reported as positive, while 40 were reported as negative for vascular injury. These were subjected to CT-angiography and seven of them had the features of vascular injury on CT-angiography. All the patients with positive Doppler or CT angiography findings were subjected to exploration. Doppler had a sensitivity of 94% and specificity of 82.5% in diagnosis of vascular injury using Binary classification test. Conclusions:: Color Doppler is an easily available, reliable, and handy method of diagnosing a vascular injury. It has a very high sensitivity and specificity in diagnosis of vascular injuries.

  15. EUV Doppler Imaging for CubeSat Platforms Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Mature the design and fabricate the Flare Initiation Doppler Imager (FIDI) instrument to demonstrate low-spacecraft-resource EUV technology (most notably,...

  16. Reexamination of the Doppler effect through Maxwell's equations.

    Science.gov (United States)

    Guo, Wei; Aktas, Yildirim

    2012-08-01

    In this work, the electric field emitted from a moving source, an electric point dipole, is analyzed for the purpose of illustrating the physics behind the Doppler effect. It is found that if the (translational) motion of the source is nonrelativistic, the Doppler effect is realized in two steps: the motion of the source first causes the dyadic Green function associated with the electric field to acquire an oscillation frequency in the far-field region of the source, and then the frequency leads to the Doppler effect. It is also demonstrated that the Doppler effect is observable only in the far-field region of the source.

  17. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1995-02-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy (DOE). This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring onsite drinking water falls outside the scope of the SESP. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control, and reporting. The ground-water sampling schedule identifies ground-water sampling .events used by PNL for environmental surveillance of the Hanford Site. Sampling is indicated as annual, semi-annual, quarterly, or monthly in the sampling schedule. Some samples are collected and analyzed as part of ground-water monitoring and characterization programs at Hanford (e.g. Resources Conservation and Recovery Act (RCRA), Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), or Operational). The number of samples planned by other programs are identified in the sampling schedule by a number in the analysis column and a project designation in the Cosample column. Well sampling events may be merged to avoid redundancy in cases where sampling is planned by both-environmental surveillance and another program.

  18. Burst Format Design for Optimum Joint Estimation of Doppler-Shift and Doppler-Rate in Packet Satellite Communications

    Directory of Open Access Journals (Sweden)

    Luca Giugno

    2007-05-01

    Full Text Available This paper considers the problem of optimizing the burst format of packet transmission to perform enhanced-accuracy estimation of Doppler-shift and Doppler-rate of the carrier of the received signal, due to relative motion between the transmitter and the receiver. Two novel burst formats that minimize the Doppler-shift and the Doppler-rate Cramér-Rao bounds (CRBs for the joint estimation of carrier phase/Doppler-shift and of the Doppler-rate are derived, and a data-aided (DA estimation algorithm suitable for each optimal burst format is presented. Performance of the newly derived estimators is evaluated by analysis and by simulation, showing that such algorithms attain their relevant CRBs with very low complexity, so that they can be directly embedded into new-generation digital modems for satellite communications at low SNR.

  19. Applications of Doppler optical coherence tomography

    Science.gov (United States)

    Xu, Zhiqiang

    A major development in biomedical imaging in the last decade has been optical coherence tomography (OCT). This technique enables microscale resolution, depth resolved imaging of the detailed morphology of transparent and nontransparent biological tissue in a noncontact and quasi-noninvasive way. In the first part of this dissertation, we will describe the development and the performance of our home-made OCT systems working with different wavelength regions based on free-space and optical fiber Michelson interferometers. The second part will focus on Doppler OCT (DOCT), an important extension of OCT, which enables the simultaneous evaluation of the structural information and of the fluid flow distribution at a localized position beneath the sample surface. Much effort has been spent during the past few years in our laboratory aimed at providing more accurate velocity measurements with an extended dynamic range. We also applied our technique in different research areas such as microfluidics and hemodynamics. Investigations on the optical properties of the biological tissues (such as absorption and scattering) corresponding to different center wavelengths, have been performed in our laboratory. We used a 10 femtosecond Ti:sapphire laser centered at about 810 nm associated with a free-space Michelson interferometer. The infrared sources were centered at about 1310 and 1560 nm with all-fiber interferometers. Comparative studies using three different sources for several in vitro biological tissues based on a graphical method illustrated how the optical properties affect the quality of the OCT images in terms of the penetration depth and backscattering intensity. We have shown the advantage of working with 810-nm emission wavelength for good backscattering amplitude and contrast, while sources emitting at 1570 nm give good penetration depth. The 1330-nm sources provide a good compromise between the two. Therefore, the choice of the source will ultimately determine the

  20. [Color Doppler sonography of focal abdominal lesions].

    Science.gov (United States)

    Licanin, Zoran; Lincender, Lidija; Djurović, V; Salihefendić, Nizama; Smajlović, Fahrudin

    2004-01-01

    Color Doppler sonography (CDS--spectral, color and power), harmonic imaging techniques (THI, PHI), possibility of 3D analysis of picture, usage of contrast agents, have raised the values of ultrasound as a diagnostic method to a very high level. THI--non-linear gray scale modality, is based on the processing of higher reflected frequencies, that has improved a picture resolution, which is presented with less artifacts and limiting effects of obesity and gases. Ultrasound contrast agents improve analysis of micro and macro circulation of the examined area, and with the assessment of velocity of supply in ROI (wash in), distribution and time of signal weakening (wash out), are significantly increasing diagnostic value of ultrasound. Besides the anatomical and topographic presentation of examined region (color, power), Color Doppler sonography gives us haemodynamic-functional information on vascularisation of that region, as well as on pathologic vascularisation if present. Avascular aspect of a focal pathologic lesion corresponds to a cyst or haematoma, while coloration and positive spectral curve discover that anechogenic lesions actually represents aneurysms, pseudoaneurysms or AVF. In local inflammatory lesion, abscess in an acute phase, CDS shows first increased, and then decreased central perfusion, while in a chronic phase, a pericapsular vascularisation is present. Contribution of CDS in differentiation of hepatic tumors (hemangioma, HCC and metastasis) is very significant. Central color dots along the peripheral blood vessels and the blush phenomenon are characteristics of capillary hemangioma, peritumoral vascular ring "basket" of HCC, and "detour" sign of metastasis. The central artery, RI from 0.45 to 0.60 and radial spreading characterize FNH. Hepatic adenoma is characterized by an intratumoral vein, and rarely by a vascular hallo. Further on, blood velocity in tumor defined by Color Doppler, distinguishes malignant from benign lesion, where 40 cm/s is a

  1. Neutral wind results from TIMED Doppler interferometer

    Science.gov (United States)

    Killeen, T.; Gablehouse, R.; Gell, D.; Johnson, R.; Niciejewski, R.; Ortland, D.; Wu, Q.; Skinner, W.; Solomon, S.; Kafkalidis, J.

    2003-04-01

    Since the launch of the NASA Thermosphere-Ionosphere-Mesosphere Energetics and Dynamics (TIMED) satellite in December 2001, the TIMED Doppler Interferometer (TIDI) has been collecting lower thermosphere and mesospheric data for over a year. After adjustments to the spectral sampling scheme and operational mode, the instrument has been optimized. Efforts have also been made to improve the instrument performance. Preliminary neutral winds from O2 (0-0) have been analyzed. Tidal features and their seasonal variation are shown clearly in the wind data, which are quantitatively consistent with model prediction. We will report our progress on these efforts.

  2. Mobile fiber-optic laser Doppler anemometer.

    Science.gov (United States)

    Stieglmeier, M; Tropea, C

    1992-07-20

    A laser Doppler anemometer (LDA) has been developed that combines the compactness and low power consumption of laser diodes and avalanche photodiodes with the flexibility and possibility of miniaturization by using fiber-optic probes. The system has been named DFLDA for laser diode fiber LDA and is especially suited for mobile applications, for example, in trains, airplanes, or automobiles. Optimization considerations of fiber-optic probes are put forward and several probe examples are described in detail. Measurement results from three typical applications are given to illustrate the use of the DFLDA. Finally, a number of future configurations of the DFLDA concept are discussed.

  3. Check list Doppler and duplex sonography. 4. rev. ed.; Checkliste Doppler- und Duplexsonografie

    Energy Technology Data Exchange (ETDEWEB)

    Kopp, Helmut [MED-Facharztzentrum, Mainz (Germany). Praxis fuer Gefaessmedizin; Ludwig, Malte [Benedictus Krankenhaus Tutzing (Germany). Gefaesszentrum

    2012-11-01

    Check list Doppler and duplex sonography includes 4 parts: (1) Basic information: technical fundamentals, equipment premises, hemodynamics. (2) Flow schemata and pitfalls. (3) Special vascular regions: arteries in the upper and lower extremities, veins in the upper and lower extremities, abdominal arteries, abdominal veins, ex-cranial brain sustaining arteries, intra-cranial brain sustaining arteries. (4) Attachment: diagnostic criteria and case studies.

  4. Doppler term in the galaxy two-point correlation function: wide-angle, velocity, Doppler lensing and cosmic acceleration effects

    OpenAIRE

    Raccanelli, Alvise; Bertacca, Daniele; Jeong, Donghui; Neyrinck, Mark C.; Szalay, Alexander S.

    2016-01-01

    We study the parity-odd part (that we shall call Doppler term) of the linear galaxy two-point correlation function that arises from wide-angle, velocity, Doppler lensing and cosmic acceleration effects. As it is important at low redshift and at large angular separations, the Doppler term is usually neglected in the current generation of galaxy surveys. For future wide-angle galaxy surveys such as Euclid, SPHEREx and SKA, however, we show that the Doppler term must be included. The effect of t...

  5. Doppler ultrasound scan during normal gestation: umbilical circulation; Ecografia Doppler en la gestacion normal: circulacion umbilical

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, T.; Sabate, J.; Martinez-Benavides, M. M.; Sanchez-Ramos, J. [Hospital Virgen Macarena. Sevilla (Spain)

    2002-07-01

    To determine normal umbilical circulation patterns by means of Doppler ultrasound scan in a healthy gestating population without risk factors and with normal perinatal results, and to evaluate any occurring modifications relative to gestational age by obtaining records kept during pregnancy. One hundred and sixteen pregnant women carrying a single fetus have been studied. These women had no risk factors, with both clinical and analytical controls, as well as ultrasound scans, all being normal. There were performed a total of 193 Doppler ultrasound scans between weeks 15 and 41 of gestation, with blood-flow analysis in the arteries and vein of the umbilical cord. The obtained information was correlated with parameters that evaluate fetal well-being (fetal monitoring and/or oxytocin test) and perinatal result (delivery type, birth weight, Apgar score). Statistical analysis was performed with the programs SPSS 6.0.1 for Windows and EPIINFO 6.0.4. With pulsed Doppler, the umbilical artery in all cases demonstrated a biphasic morphology with systolic and diastolic components and without retrograde blood flow. As the gestation period increased, there was observed a progressive decrease in resistance along with an increase in blood-flow velocity during the diastolic phase. The Doppler ultrasound scan is a non-invasive method that permits the hemodynamic study of umbilical blood circulation. A knowledge of normal blood-flow signal morphology, as well as of the normal values for Doppler indices in relation to gestational age would permit us to utilize this method in high-risk pregnancies. (Author) 30 refs.

  6. Initial Results from the XUV Doppler Telescope

    Science.gov (United States)

    Kano, R.; Hara, H.; Kobayashi, K.; Kumagai, K.; Nagata, S.; Sakao, T.; Shimizu, T.; Tsuneta, S.; Yoshida, T.

    We developed a unique telescope to obtain simultaneous XUV images and the velocity maps by measuring the line-of-sight Doppler shifts of the Fe XIV 211A&ring line (T = 1.8 MK): the Solar XUV Doppler Telescope (hereafter XDT). The telescope was launched by the Institute of Space and Astronautical Science with the 22nd S520 rocket on January 31, 1998, and took 14 XUV whole sun images during 5 minutes. Simultaneous observations of XDT with Yohkoh (SXT), SOHO (EIT, CDS, LASCO and MDI) were successfully carried out. The images taken with EIT, XDT and SXT are able to cover the wide temperature ranging from 1 to 10 MK, and clearly show the multi-temperature nature of the solar corona. Indeed, we notice that both the cool (1-2 MK) loops observed with EIT and XDT, and the hot (>3 MK) loops observed with SXT exist in the same active regions but in a spatially exclusive way. The XDT red-blue ratio between longer- and shorter-wavelength bands of Fe XIV 211A&ring line indicates a possible down-flow of 1.8 MK plasma near the footpoints of multiple cool loops

  7. Reactor Vessel Surveillance Program for Advanced Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Kyeong-Hoon; Kim, Tae-Wan; Lee, Gyu-Mahn; Kim, Jong-Wook; Park, Keun-Bae; Kim, Keung-Koo

    2008-10-15

    This report provides the design requirements of an integral type reactor vessel surveillance program for an integral type reactor in accordance with the requirements of Korean MEST (Ministry of Education, Science and Technology Development) Notice 2008-18. This report covers the requirements for the design of surveillance capsule assemblies including their test specimens, test block materials, handling tools, and monitors of the surveillance capsule neutron fluence and temperature. In addition, this report provides design requirements for the program for irradiation surveillance of reactor vessel materials, a layout of specimens and monitors in the surveillance capsule, procedures of installation and retrieval of the surveillance capsule assemblies, and the layout of the surveillance capsule assemblies in the reactor.

  8. The Sharper Image for Surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Hazi, A

    2006-01-13

    A technique adapted by Livermore scientists to take the twinkle out of stars is now being used to improve the resolution of long-range surveillance systems trained on earthbound objects. The speckle-imaging technique involves taking tens to hundreds of pictures with short-exposure times and reconstructing a single, sharp image using image-processing software. The technique drew the interest of Livermore engineer Carmen Carrano. She developed a prototype remote-surveillance system that can produce a detailed image of a face from a couple of kilometers away. The system also helps identify vehicles tens of kilometers away and improves the viewing of large structures more than 60 kilometers away.

  9. Congenital anomalies surveillance in Canada.

    Science.gov (United States)

    Lowry, R Brian

    2008-01-01

    Congenital anomalies (CA) are present in approximately 3% of all newborn babies and account for about 12% of paediatric hospital admissions. They represent an important public health problem. Surveillance is especially important so that preventive measures such as folic acid fortification can be properly assessed without resorting to a series of ad hoc studies. Canada's surveillance of CAs is weak, with only Alberta and British Columbia having established sytems. Most provinces have perinatal systems but their CA data are incomplete and they do not capture terminations of pregnancy. The same is true of the Public Health Agency of Canada's system. A new system, the Fetal Alert Network, has been proposed for Ontario, which represents a start but will require additional sources of ascertainment if it is to be a truly population-based system for Ontario.

  10. Surveillance of Space in Australia

    Science.gov (United States)

    Newsam, G.

    Australia's geography and technology base got it off to a flying start in the early days of surveillance of space, starting with CSIRO's first radio telescope in the 1940's and climaxing in NASA's establishment of station 43 in the Deep Space Network at Tidbinbilla in 1965. But Britain's exit from space and the subsequent closure of the Woomera launch range and associated space tracking facilities in the early 1970's saw the start of a long draw-down of capability. Programs such as CSIRO's radio astronomy telescopes, Electro-Optic Systems' adoption of laser technology for satellite laser ranging and tracking system, and the exploration of the use of technology developed in Australia's over-the-horizon-radar program for surveillance of space, kept some interest in the problem alive, but there has been no serious national investment in the area for the last thirty years. Recently, however, increased awareness of the vulnerability of space systems and the need to include potential opponents' space capabilities in operations planning has led to a revival of interest in space situational awareness within the Australian Defence Organisation. While firm commitments to new systems must wait on the next Defence White Paper due out at the end of 2007 and the policy directions it formally endorses, discussions have already started with the US on participating in the Space Surveillance Network (SSN) and developing a comprehensive space situational awareness capability. In support of these initiatives the Defence Science and Technology Organisation (DSTO) is drawing up an inventory of relevant Australian capabilities, technologies and activities: the paper will describe the findings of this inventory, and in particular local technologies and systems that might be deployed in Australia to contribute to the SSN. In the optical regime the available options are rather limited; they centre primarily on the satellite laser ranging technology developed by Electro-Optic Systems and

  11. Mining Surveillance and Maintenance Dollars

    Energy Technology Data Exchange (ETDEWEB)

    MARTINEZ, R.

    2000-02-01

    Accelerating site cleanup to reduce facility risks to the workers, the public and the environment during a time of declining federal budgets represents a significant technical and economic challenge to U.S. Department of Energy (DOE) Operations Offices and their respective contractors. A significant portion of a facility's recurring annual expenses are associated with routine, long-term surveillance and maintenance (S&M) activities. However, ongoing S&M activities do nothing to reduce risks and basically spend money that could be reallocated towards facility deactivation. This paper discusses the background around DOE efforts to reduce surveillance and maintenance costs, one approach used to perform cost reviews, lessons learned from field implementation and what assistance is available to assist DOE sites in performing these evaluations.

  12. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1997-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL)(a) for the US Department of Energy (DOE). This document contains the planned 1997 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. In addition, Section 3.0, Biota, also reflects a rotating collection schedule identifying the year a specific sample is scheduled for collection. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, General Environmental Protection Program, and DOE Order 5400.5, Radiation Protection of the Public and the Environment. The sampling methods will be the same as those described in the Environmental Monitoring Plan, US Department of Energy, Richland Operations Office, DOE/RL91-50, Rev. 1, US Department of Energy, Richland, Washington.

  13. Functional Doppler optical coherence tomography for cortical blood flow imaging

    Science.gov (United States)

    Yu, Lingfeng; Liu, Gangjun; Nguyen, Elaine; Choi, Bernard; Chen, Zhongping

    2010-02-01

    Optical methods have been widely used in basic neuroscience research to study the cerebral blood flow dynamics in order to overcome the low spatial resolution associated with magnetic resonance imaging and positron emission tomography. Although laser Doppler imaging and laser speckle imaging can map out en face cortical hemodynamics and columns, depth resolution is not available. Two-photon microscopy has been used for mapping cortical activity. However, flow measurement requires fluorescent dye injection, which can be problematic. The noninvasive and high resolution tomographic capabilities of optical coherence tomography make it a promising technique for mapping depth resolved cortical blood flow. Here, we present a functional Doppler optical coherence tomography (OCT) imaging modality for quantitative evaluation of cortical blood flow in a mouse model. Fast, repeated, Doppler OCT scans across a vessel of interest were performed to record flow dynamic information with a high temporal resolution of the cardiac cycles. Spectral Doppler analysis of continuous Doppler images demonstrates how the velocity components and longitudinally projected flow-volume-rate change over time, thereby providing complementary temporal flow information to the spatially distributed flow information of Doppler OCT. The proposed functional Doppler OCT imaging modality can be used to diagnose vessel stenosis/blockage or monitor blood flow changes due to pharmacological agents/neuronal activities. Non-invasive in-vivo mice experiments were performed to verify the capabilities of function Doppler OCT.

  14. Measurement of depth of burns by laser Doppler perfusion imaging

    NARCIS (Netherlands)

    Droog, E.J.; Droog, E.J.; Steenbergen, Wiendelt; Sjöberg, F.

    2001-01-01

    Laser Doppler perfusion imaging (LDPI), is a further development in laser Doppler flowmetry (LDF). Its advantage is that it enables assessment of microvascular blood flow in a predefined skin area rather than, as for LDF, in one place. In many ways this method seems to be more promising than LDF in

  15. Micro-Doppler classification of riders and riderless horses

    Science.gov (United States)

    Tahmoush, David

    2014-05-01

    Micro-range Micro-Doppler can be used to isolate particular parts of the radar signature, and in this case we demonstrate the differences in the signature between a walking horse versus a walking horse with a rider. Using micro-range micro-Doppler, we can distinguish the radar returns from the rider as separate from the radar returns of the horse.

  16. A Rayleigh Doppler Frequency Estimator Derived from Maximum Likelihood Theory

    DEFF Research Database (Denmark)

    Hansen, Henrik; Affes, Sofiene; Mermelstein, Paul

    1999-01-01

    Reliable estimates of Rayleigh Doppler frequency are useful for the optimization of adaptive multiple access wireless receivers.The adaptation parameters of such receivers are sensitive to the amount of Doppler and automatic reconfiguration to the speed of terminalmovement can optimize cell...

  17. Measurement of depth of burns by laser Doppler perfusion imaging

    NARCIS (Netherlands)

    Droog, E.J.; Steenbergen, W.; Sjöberg, F.

    2001-01-01

    Laser Doppler perfusion imaging (LDPI), is a further development in laser Doppler flowmetry (LDF). Its advantage is that it enables assessment of microvascular blood flow in a predefined skin area rather than, as for LDF, in one place. In many ways this method seems to be more promising than LDF in

  18. Compressive sensing for high resolution profiles with enhanced Doppler performance

    NARCIS (Netherlands)

    Anitori, L.; Hoogeboom, P.; Chevalier, F. Le; Otten, M.P.G.

    2012-01-01

    In this paper we demonstrate how Compressive Sensing (CS) can be used in pulse-Doppler radars to improve the Doppler performance while preserving range resolution. We investigate here two types of stepped frequency waveforms, the coherent frequency bursts and successive frequency ramps, which can be

  19. An elementary approach to the gravitational Doppler shift

    Science.gov (United States)

    Wörner, C. H.; Rojas, Roberto

    2017-01-01

    In college physics courses, treatment of the Doppler effect is usually done far from the first introduction to kinematics. This paper aims to apply a graphical treatment to describe the gravitational redshift, by considering the Doppler effect in two accelerated reference frames and exercising the equivalence principle. This approach seems appropriate to discuss with beginner students and could serve to enrich the didactic processes.

  20. Detection and visualization to Doppler sensitive sonar pulses

    NARCIS (Netherlands)

    Bertrand, D.B.; IJsselmuide, S.P. van; Beerens, S.P.

    2006-01-01

    In anti-submarine warfare, the use of Doppler sensitive sonar pulses is common practice. In particular, the wideband Doppler sensitive PTFM pulse (Pulse Train Frequency Modulation) is a powerful tool for detection in reverberation limited conditions. Nevertheless, this pulse is not operationally

  1. The value of Doppler ultrasound in cirrhosis and portal hypertension

    NARCIS (Netherlands)

    Kok, T; van der Jagt, EJ; Haagsma, EB; Bijleveld, CMA; Jansen, PLM; Boeve, WJ

    1999-01-01

    Background: Cirrhosis and portal hypertension affect the flow profile of the liver vasculature. In these conditions Doppler ultrasound can provide important information on the hemodynamics of the portal venous system, the hepatic artery and the hepatic veins. Methods: The value of Doppler ultrasound

  2. A Rayleigh Doppler frequency estimator derived from maximum likelihood theory

    DEFF Research Database (Denmark)

    Hansen, Henrik; Affes, Sofiéne; Mermelstein, Paul

    1999-01-01

    Reliable estimates of Rayleigh Doppler frequency are useful for the optimization of adaptive multiple access wireless receivers. The adaptation parameters of such receivers are sensitive to the amount of Doppler and automatic reconfiguration to the speed of terminal movement can optimize cell cap...

  3. Attaching Hollywood to a Surveillant Assemblage: Normalizing Discourses of Video Surveillance

    Directory of Open Access Journals (Sweden)

    Randy K Lippert

    2015-10-01

    Full Text Available This article examines video surveillance images in Hollywood film. It moves beyond previous accounts of video surveillance in relation to film by theoretically situating the use of these surveillance images in a broader “surveillant assemblage”. To this end, scenes from a sample of thirty-five (35 films of several genres are examined to discern dominant discourses and how they lend themselves to normalization of video surveillance. Four discourses are discovered and elaborated by providing examples from Hollywood films. While the films provide video surveillance with a positive associative association it is not without nuance and limitations. Thus, it is found that some forms of resistance to video surveillance are shown while its deterrent effect is not. It is ultimately argued that Hollywood film is becoming attached to a video surveillant assemblage discursively through these normalizing discourses as well as structurally to the extent actual video surveillance technology to produce the images is used.

  4. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1994-02-01

    This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring the onsite drinking water falls outside the scope of the SESP. The Hanford Environmental Health Foundation is responsible for monitoring the nonradiological parameters as defined in the National Drinking Water Standards while PNL conducts the radiological monitoring of the onsite drinking water. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize the expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control and reporting. The ground-water sampling schedule identifies ground-water sampling events used by PNL for environmental surveillance of the Hanford Site.

  5. Mobile Surveillance and Monitoring Robots

    Energy Technology Data Exchange (ETDEWEB)

    Kimberly, Howard R.; Shipers, Larry R.

    1999-07-14

    Long-term nuclear material storage will require in-vault data verification, sensor testing, error and alarm response, inventory, and maintenance operations. System concept development efforts for a comprehensive nuclear material management system have identified the use of a small flexible mobile automation platform to perform these surveillance and maintenance operations. In order to have near-term wide-range application in the Complex, a mobile surveillance system must be small, flexible, and adaptable enough to allow retrofit into existing special nuclear material facilities. The objective of the Mobile Surveillance and Monitoring Robot project is to satisfy these needs by development of a human scale mobile robot to monitor the state of health, physical security and safety of items in storage and process; recognize and respond to alarms, threats, and off-normal operating conditions; and perform material handling and maintenance operations. The system will integrate a tool kit of onboard sensors and monitors, maintenance equipment and capability, and SNL developed non-lethal threat response technology with the intelligence to identify threats and develop and implement first response strategies for abnormal signals and alarm conditions. System versatility will be enhanced by incorporating a robot arm, vision and force sensing, robust obstacle avoidance, and appropriate monitoring and sensing equipment.

  6. Use of GPS network data for HF Doppler measurements interpretation

    CERN Document Server

    Petrova, Inna R; Latypov, Ruslan R

    2014-01-01

    The method of measurement of Doppler frequency shift of ionospheric signal - HF Doppler technique - is one of well-known and widely used methods of ionosphere research. It allows to research various disturbances in the ionosphere. There are some sources of disturbances in the ionosphere. These are geomagnetic storms, solar flashes, metrological effects, atmospheric waves. This method allows to find out the influence of earthquakes, explosions and other processes on the ionosphere, which occur near to the Earth. HF Doppler technique has the high sensitivity to small frequency variations and the high time resolution, but interpretation of results is difficult. In this work we make an attempt to use GPS data for Doppler measurements interpretation. Modeling of Doppler frequency shift variations with use of TEC allows to separate ionosphere disturbances of medium scale.

  7. Embolic Doppler ultrasound signal detection via fractional Fourier transform.

    Science.gov (United States)

    Gençer, Merve; Bilgin, Gökhan; Aydın, Nizamettin

    2013-01-01

    Computerized analysis of Doppler ultrasound signals can aid early detection of asymptomatic circulating emboli. For analysis, physicians use informative features extracted from Doppler ultrasound signals. Time -frequency analysis methods are useful tools to exploit the transient like signals such as Embolic signals. Detection of discriminative features would be the first step toward automated analysis of embolic Doppler ultrasound signals. The most problematic part of setting up emboli detection system is to differentiate embolic signals from confusing similar wave-like patterns such as Doppler speckle and artifacts caused by tissue movement, probe tapping, speaking etc. In this study, discrete version of fractional Fourier transform is presented as a solution in the detection of emboli in digitized Doppler ultrasound signals. An accurate set of parameters are extracted using short time Fourier transform and fractional Fourier transform and the results are compared to reveal detection quality. Experimental results prove the efficiency of fractional Fourier transform in which discriminative features becomes more evident.

  8. One way Doppler extractor. Volume 1: Vernier technique

    Science.gov (United States)

    Blasco, R. W.; Klein, S.; Nossen, E. J.; Starner, E. R.; Yanosov, J. A.

    1974-01-01

    A feasibility analysis, trade-offs, and implementation for a One Way Doppler Extraction system are discussed. A Doppler error analysis shows that quantization error is a primary source of Doppler measurement error. Several competing extraction techniques are compared and a Vernier technique is developed which obtains high Doppler resolution with low speed logic. Parameter trade-offs and sensitivities for the Vernier technique are analyzed, leading to a hardware design configuration. A detailed design, operation, and performance evaluation of the resulting breadboard model is presented which verifies the theoretical performance predictions. Performance tests have verified that the breadboard is capable of extracting Doppler, on an S-band signal, to an accuracy of less than 0.02 Hertz for a one second averaging period. This corresponds to a range rate error of no more than 3 millimeters per second.

  9. Doppler-cancelled response to VLF gravitational waves

    Science.gov (United States)

    Caporali, A.

    1981-01-01

    The interaction of long periodic gravitational waves with a three link microwave system known as the Doppler Cancelling System is discussed. This system, which was developed for a gravitational redshift experiment, uses one-way and two-way Doppler informatin to construct the beat signal of two reference oscillators moving with respect to each other. The geometric optics approximation is used to derive the frequency shift produced on a light signal propagating in a gravitational wave space-time. The signature left on the Doppler-cancelled beat by burst and continuous gravitational waves is analyzed. A comparison is made between the response to gravitational waves of the Doppler Cancelling System and that of a Doppler tracking system which employs two-way, round-trip radio waves. A three-fold repetition of the gravitational wave form is found to be a common feature of the response functions of both systems. These two functions otherwise exhibit interesting differences.

  10. Limits on Planetary Companions from Doppler Surveys of Nearby Stars

    CERN Document Server

    Howard, Andrew W

    2016-01-01

    Most of our knowledge of planets orbiting nearby stars comes from Doppler surveys. For spaced-based, high-contrast imaging missions, nearby stars with Doppler-discovered planets are attractive targets. The known orbits tell imaging missions where and when to observe, and the dynamically-determined masses provide important constraints for the interpretation of planetary spectra. Quantifying the set of planet masses and orbits that could have been detected will enable more efficient planet discovery and characterization. We analyzed Doppler measurements from Lick and Keck Observatories collected by the California Planet Survey. We focused on stars that are likely targets for three space-based planet imaging mission concepts studied by NASA--WFIRST-AFTA, Exo-C, and Exo-S. The Doppler targets are primarily F8 and later main sequence stars, with observations spanning 1987-2014. We identified 76 stars with Doppler measurements from the prospective mission target lists. We developed an automated planet search and a ...

  11. Doplerovi brodski navigacioni brzinomjeri / Maritime navigational Doppler logs

    Directory of Open Access Journals (Sweden)

    Milovan Unković

    2006-01-01

    Full Text Available Doplerovi navigacioni brodski brzinomjeri rade na principu Doplerovog efekta. Doplerov predajni projektor emituje snop ultrazvučnih vibracija u vodi, a drugi (ili isti projektor prima odbijeni signal od dna ili od sloja vode. U ovom radu opisana je teorija Doplerovog efekta, primjena te teorije na brodskim brzinomjerima, konstrukcija i karakteristike savremenih Doplerovih brzinomjera. / The Doppler maritime navigational logs are based on measurement of the Doppler effect. A Doppler log transmitting transducer emits beam of sound vibration in the water, and a second (or the same transducer receives the echo from the sea bed or -water layer. In this article describes theory of Doppler effect, using this theory in maritime logs, construction and performance of modern Doppler logs.

  12. A radar unattended ground sensor with micro-Doppler capabilities for false alarm reduction

    Science.gov (United States)

    Tahmoush, Dave; Silvious, Jerry; Burke, Ed

    2010-10-01

    Unattended ground sensors (UGS) provide the capability to inexpensively secure remote borders and other areas of interest. However, the presence of normal animal activity can often trigger a false alarm. Accurately detecting humans and distinguishing them from natural fauna is an important issue in security applications to reduce false alarm rates and improve the probability of detection. In particular, it is important to detect and classify people who are moving in remote locations and transmit back detections and analysis over extended periods at a low cost and with minimal maintenance. We developed and demonstrate a compact radar technology that is scalable to a variety of ultra-lightweight and low-power platforms for wide area persistent surveillance as an unattended, unmanned, and man-portable ground sensor. The radar uses micro-Doppler processing to characterize the tracks of moving targets and to then eliminate unimportant detections due to animals as well as characterize the activity of human detections. False alarms from sensors are a major liability that hinders widespread use. Incorporating rudimentary intelligence into sensors can reduce false alarms but can also result in a reduced probability of detection. Allowing an initial classification that can be updated with new observations and tracked over time provides a more robust framework for false alarm reduction at the cost of additional sensor observations. This paper explores these tradeoffs with a small radar sensor for border security. Multiple measurements were done to try to characterize the micro-Doppler of human versus animal and vehicular motion across a range of activities. Measurements were taken at the multiple sites with realistic but low levels of clutter. Animals move with a quadrupedal motion, which can be distinguished from the bipedal human motion. The micro-Doppler of a vehicle with rotating parts is also shown, along with ground truth images. Comparisons show large variations for

  13. TIMED Doppler Interferometer: Overview and recent results

    Science.gov (United States)

    Killeen, T. L.; Wu, Q.; Solomon, S. C.; Ortland, D. A.; Skinner, W. R.; Niciejewski, R. J.; Gell, D. A.

    2006-10-01

    The Thermosphere-Ionosphere-Mesosphere Energetics and Dynamics (TIMED) satellite carries a limb-scanning Fabry-Perot interferometer designed to perform remote-sensing measurements of upper atmosphere winds and temperatures globally. This instrument is called the TIMED Doppler Interferometer, or TIDI. This paper provides an overview of the TIDI instrument design, on-orbit performance, operational modes, data processing and inversion procedures, and a summary of wind results to date. Daytime and nighttime neutral winds in the mesosphere and lower thermosphere/ionosphere (MLTI) are measured on TIDI using four individual scanning telescopes that collect light from various upper atmosphere airglow layers on both the cold and warm sides of the high-inclination TIMED spacecraft. The light is spectrally analyzed using an ultrastable plane etalon Fabry-Perot system with sufficient spectral resolution to determine the Doppler line characteristics of atomic and molecular emissions emanating from the MLTI. The light from all four telescopes and from an internal calibration field passes through the etalon and is combined on a single image plane detector using a Circle-to-Line Interferometer Optic (CLIO). The four geophysical fields provide orthogonal line-of-sight measurements to either side of the satellite's path and these are analyzed to produce altitude profiles of vector winds in the MLTI. The TIDI wind measurements presented here are from the molecular oxygen (0-0) band, covering the altitude region 85-105 km. The unique TIDI design allows for more extended local time coverage of wind structures than previous wind-measuring instruments from high-inclination satellites. The TIDI operational performance has been nominal except for two anomalies: (1) higher than expected background white light caused by a low-level light leak and (2) ice deposition on cold optical surfaces. Both anomalies are well understood and the instrumental modes and data analysis techniques have been

  14. HIV surveillance in complex emergencies.

    Science.gov (United States)

    Salama, P; Dondero, T J

    2001-04-01

    Many studies have shown a positive association between both migration and temporary expatriation and HIV risk. This association is likely to be similar or even more pronounced for forced migrants. In general, HIV transmission in host-migrant or host-forced-migrant interactions depends on the maturity of the HIV epidemic in both the host and the migrant population, the relative seroprevalence of HIV in the host and the migrant population, the prevalence of other sexually transmitted infections (STIs) that may facilitate transmission, and the level of sexual interaction between the two communities. Complex emergencies are the major cause of mass population movement today. In complex emergencies, additional factors such as sexual interaction between forced-migrant populations and the military; sexual violence; increasing commercial sex work; psychological trauma; and disruption of preventive and curative health services may increase the risk for HIV transmission. Despite recent success in preventing HIV infection in stable populations in selected developing countries, internally displaced persons and refugees (or forced migrants) have not been systematically included in HIV surveillance systems, nor consequently in prevention activities. Standard surveillance systems that rely on functioning health services may not provide useful data in many complex emergency settings. Secondary sources can provide some information in these settings. Little attempt has been made, however, to develop innovative HIV surveillance systems in countries affected by complex emergencies. Consequently, data on the HIV epidemic in these countries are scarce and HIV prevention programs are either not implemented or interventions are not effectively targeted. Second generation surveillance methods such as cross-sectional, population-based surveys can provide rapid information on HIV, STIs, and sexual behavior. The risks for stigmatization and breaches of confidentiality must be recognized

  15. Avaliação dos tumores hepáticos ao Doppler Doppler evaluation of liver tumors

    Directory of Open Access Journals (Sweden)

    Márcio Martins Machado

    2004-10-01

    Full Text Available Os avanços recentes na ultra-sonografia têm ampliado a possibilidade de detecção de tumores hepáticos. Isto tem auxiliado na perspectiva de melhora do prognóstico destes pacientes, à medida que novas técnicas terapêuticas têm surgido. Neste artigo os autores relatam achados ao Doppler que podem auxiliar na identificação e caracterização dos tumores hepáticos, avaliando dados do Doppler colorido, pulsado e do Doppler de amplitude ("power Doppler". Fazem, também, referência a novas modalidades de imagem, como o uso da harmônica.Recent advances in ultrasound have optimized the detection of liver tumors and helped to improve the prognosis of patients with this condition as newly developed and improved therapeutic modalities have been established. The authors review important Doppler findings which may help in the identification and characterization of some hepatic tumors through the evaluation of color Doppler, pulsed Doppler and power Doppler features. New imaging methods such as the use of harmonics imaging are also reviewed.

  16. Universal miniaturized signal evaluation for laser doppler anemometers; Universelle Miniatur-Signalauswertung fuer die Laser Doppler Anemometrie

    Energy Technology Data Exchange (ETDEWEB)

    Wnuck, J. von; Strunck, V.; Dopheide, D.

    1994-01-01

    A laser doppler anemometer (LDA) is a contactless optical sensor for flow rate measurement. Interference of two laser beams generates a measuring volume with interference lines in the point of intersection. A particle moving through the measuring volume with a current scatters light modulated wiith the doppler frequency, which is received by a detector. The frequency of the doppler-modulated light is proportional to the velocity of the particle. The report describes the technical details of an electronic evaluation system for laser doppler signals in the time range using programmable gate arrays by Xilinix. (orig.) [Deutsch] Ein Laser Doppler Anemometer (LDA) ist ein beruehrungsloser optischer Sensor, der Stroemungsgeschwindigkeiten misst. Die Ueberlagerung zweier Laserstrahlen erzeugt im Schnittpunkt ein Messvolumen mit Inferenzstreifen. Ein Teilchen, das sich mit einer Stroemung durch das Messvolumen bewegt, streut mit der Doppelfrequenz des Doppler moduliertes Licht, das von einem Detektor empfangen wird. Die Frequenz des Doppler-modulierten Lichts ist der Geschwindigkeit des Teilchens proportional. Hier wird die technische Realisierung einer Auswerteelektronik fuer Laser Doppler Signale im Zeitbereich mit programmierbaren Gate-Arrays von Xilinx beschrieben. (orig.)

  17. Color Doppler US of superficial adenopathies; Il color Doppler nelle adenopatie superficiali

    Energy Technology Data Exchange (ETDEWEB)

    Giovagnorio, F. [Rome Univ. (Italy). 1. Cattedra di Radiologia

    1999-03-01

    Superficial lymph node are frequently involved in different diseases. Their location makes them suitable for effective assessment with high-resolution US and color Doppler has been recently suggested as a tool for increasing sensitivity in lymph node studies. Thus the author investigated the main vascular patterns detectable in abnormal superficial lymph nodes. [Italian] Numerosa malattie con natura differente coinvolgono i linfonodi superficiali: la localizzazione ne consente l'esplorazione con ecografia con alta risoluzione e lo studio mediante eco color Doppler e' stato proposto negli ultimi anni incontrando notevole sviluppo in tempi recenti. Scopo del lavoro e' illustrare il contributo personale nella definizione dei principali quadri riscontrabili nelle diverse adenopatie superficiali.

  18. Fractal fluctuations in transcranial Doppler signals

    Science.gov (United States)

    West, B. J.; Zhang, R.; Sanders, A. W.; Miniyar, S.; Zuckerman, J. H.; Levine, B. D.

    1999-03-01

    Cerebral blood flow (CBF) velocity measured using transcranial Doppler ultrasonography (TCD) is not strictly constant, but has both a systematic and random component. This behavior may indicate that the axial blood flow in the middle cerebral artery is a chaotic process. Herein we use the relative dispersion, the ratio of the standard deviation to the mean, to show by systematically aggregating the data that the correlation in the beat-to-beat CBF time series is a modulated inverse power law. This scaling of the CBF time series indicates the existence of long-time memory in the underlying control process. We argue herein that the control system has allometric properties that enable it to maintain a relatively constant brain perfusion.

  19. Role of transcranial Doppler in cerebrovascular disease

    Directory of Open Access Journals (Sweden)

    Amit A Kulkarni

    2016-01-01

    Full Text Available Transcranial Doppler (TCD is the only noninvasive modality for the assessment of real-time cerebral blood flow. It complements various anatomic imaging modalities by providing physiological-flow related information. It is relatively cheap, easily available, and can be performed at the bedside. It has been suggested as an essential component of a comprehensive stroke centre. In addition to its importance in acute cerebrovascular ischemia, its role is expanding in the evaluation of cerebral hemodynamics in various disorders of the brain. The “established” clinical indications for the use of TCD include cerebral ischemia, sickle cell disease, detection of right-to-left shunts, subarachnoid hemorrhage, periprocedural or surgical monitoring, and brain death. We present the role of TCD in acute cerebrovascular ischemia, sonothrombolysis, and intracranial stenosis.

  20. The Doppler peaks from a generic defect

    CERN Document Server

    Magueijo, J

    1996-01-01

    We investigate which of the exotic Doppler peak features found for textures and cosmic strings are generic novelties pertaining to defects. We find that the ``out of phase'' texture signature is an accident. Generic defects, when they generate a secondary peak structure similar to inflation, apply to it an additive shift. It is not necessary for this shift to be ``out of phase''. We also show which factors are responsible for the absence of secondary oscillations found for cosmic strings. Within this general analysis we finally consider the conditions under which topological defects and inflation can be confused. It is argued that only \\Omega=1 inflation and a defect with a horizon size coherence length have a chance to be confused. Any other inflationary or defect model always differ distinctly. (To appear in the proceedings of the XXXIth Moriond meeting, ``Microwave Background Anisotropies'')

  1. Laser Doppler vibrometry: new ENT applications

    Science.gov (United States)

    Stasche, Norbert; Baermann, M.; Kempe, C.; Hoermann, Karl; Foth, Hans-Jochen

    1996-12-01

    Common audiometry often does not really allow a reliable and objective differential diagnosis of hearing disorders such as otosclerosis, adhesive otitis, ossicular interruption or tinnitus, even though several methods might be used complementarily. In recent years, some experimental studies on middle ear mechanics established laser Doppler vibrometry (LDV) as a useful method allowing objective measurement of human tympanic membrane displacement. The present study on LDV investigated the clinical use of this new method under physiological conditions. LDV proved to be a fast, reproducible, non-invasive and very sensitive instrument to characterize ear-drum vibrations in various middle ear dysfunctions, except in tinnitus patients. For future applications, improved optical characteristics of the vibrometer might result in a better differential diagnosis of subjective and objective tinnitus, otoacoustic emissions or Morbus Meniere.

  2. Heartrate variation of umbilical artery Doppler waveforms.

    Science.gov (United States)

    Hoskins, P R; Johnstone, F D; Chambers, S E; Haddad, N G; White, G; McDicken, W N

    1989-01-01

    Umbilical artery Doppler waveforms from 20 patients were used to investigate the dependence of resistance index and pulsatility index on beat to beat pulse length over short time periods for individual patients, and on the usefulness of a common normalisation formula. For individual patients the resistance index and pulsatility index were only partially correlated with pulse length. Changes in both indices occurred independently of pulse length. Use of a common normalisation formula resulted in no significant reduction of the coefficient of variation of the resistance index (p greater than 0.1), and a reduction in the coefficient of variation of the pulsatility index of 10% (p greater than 0.001). It is concluded that short term changes in resistance index and pulsatility index cannot be corrected by a common normalisation formula.

  3. Correlation and Sequential Filtering with Doppler Measurements

    Institute of Scientific and Technical Information of China (English)

    WANGJianguo; HEPeikun; HANYueqiu; WUSiliang

    2004-01-01

    Two sequential filters are developed for Doppler radar measurements in the presence of correlation between range and range rate measurement errors. Two ideal linear measurement equations with the pseudo measurements are constructed via block-partitioned Cholesky factorization and the practical measurement equationswith the pseudo measurements are obtained through the direction cosine estimation and error compensation. The resulting sequential filters make the position measurement be possibly processed before the pseudo measurement and hence the more accurate direction cosine estimate can be obtained from the filtered position estimate rather than the predicted state estimate. The numerical simulations with different rangerange rate correlation coefficients show thatthe proposed two sequential filters are almost equivalent in performance but both superior to the conventional extended Kalman filter for different correlation coefficients.

  4. Doppler cooling and trapping on forbidden transitions.

    Science.gov (United States)

    Binnewies, T; Wilpers, G; Sterr, U; Riehle, F; Helmcke, J; Mehlstäubler, T E; Rasel, E M; Ertmer, W

    2001-09-17

    Ultracold atoms at temperatures close to the recoil limit have been achieved by extending Doppler cooling to forbidden transitions. A cloud of (40)Ca atoms has been cooled and trapped to a temperature as low as 6 microK by operating a magnetooptical trap on the spin-forbidden intercombination transition. Quenching the long-lived excited state with an additional laser enhanced the scattering rate by a factor of 15, while a high selectivity in velocity was preserved. With this method, more than 10% of precooled atoms from a standard magnetooptical trap have been transferred to the ultracold trap. Monte Carlo simulations of the cooling process are in good agreement with the experiments.

  5. Phase Doppler anemometry as an ejecta diagnostic

    Science.gov (United States)

    Bell, D. J.; Chapman, D. J.

    2017-01-01

    When a shock wave is incident on a free surface, micron sized pieces of the material can be ejected from that surface. Phase Doppler Anemometry (PDA) is being developed to simultaneously measure the sizes and velocities of the individual shock induced ejecta particles; providing an important insight into ejecta phenomena. The results from experiments performed on the 13 mm bore light gas gun at the Institute of Shock Physics, Imperial College London are presented. Specially grooved tin targets were shocked at pressures of up to 14 GPa, below the melt on release pressure, to generate ejecta particles. These experiments are the first time that PDA has been successfully fielded on dynamic ejecta experiments. The results and current state of the art of the technique are discussed along with the future improvements required to optimise performance and increase usability.

  6. Calibration of a cw infrared Doppler lidar.

    Science.gov (United States)

    Schwiesow, R L; Cupp, R E

    1980-09-15

    A moving scattering target used as a transfer standard allows absolute calibration of the response of a cw Doppler lidar to an atmospheric target. The lidar in this study operated at a 10.6-microm wavelength. Consideration of the distribution of radiant energy density near the focus of the lidar transceiver permits measurement of a backscatter coefficient from a distributed array of scatterers, such as atmospheric aerosols, based on the diffuse reflectance of the surface of the transfer standard. The minimum detectable signal for our system with a 5-sec averaging time corresponds to a backscatter coefficient of 2.4 x 10(-12) m (-1) sr (-1) +/- 2.5 dB, which is ~ 9 dB greater than the theoretical threshold. Calibration shows that the lidar response is 5+/-1 dB less than the ideal limit for signal powers well above the minimum detectable signal.

  7. The recondite intricacies of Zeeman Doppler mapping

    CERN Document Server

    Stift, M J; Cowley, C R

    2011-01-01

    We present a detailed analysis of the reliability of abundance and magnetic maps of Ap stars obtained by Zeeman Doppler mapping (ZDM). It is shown how they can be adversely affected by the assumption of a mean stellar atmosphere instead of appropriate "local" atmospheres corresponding to the actual abundances in a given region. The essenceof the difficulties was already shown by Chandrasekhar's picket-fence model. The results obtained with a suite of Stokes codes written in the Ada programming language and based on modern line-blanketed atmospheres are described in detail. We demonstrate that the high metallicity values claimed to have been found in chemically inhomogeneous Ap star atmospheres would lead to local temperature structures, continuum and line intensities, and line shapes that differ significantly from those predicted by a mean stellar atmosphere. Unfortunately, past applications of ZDM have consistently overlooked the intricate aspects of metallicity with their all-pervading effects. The erroneou...

  8. Position finding using simple Doppler sensors

    Science.gov (United States)

    Schelkshorn, S.; Detlefsen, J.

    2007-06-01

    An increasing number of modern applications and services is based on the knowledge of the users actual position. Depending on the application a rough position estimate is sufficient, e. g. services in cellular networks that use the information about the users actual cell. Other applications, e. g. navigation systems use the GPS-System for accurate position finding. Beyond these outdoor applications a growing number of indoor applications requires position information. The previously mentioned methods for position finding (mobile cell, GPS) are not usable for these indoor applications. Within this paper we will present a system that relies on the simultaneous measurement of doppler signals at four different positions to obtain position and velocity of an unknown object. It is therefore suiteable for indoor usage, extendig already existing wireless infrastructure.

  9. Microscale Heat Conduction Models and Doppler Feedback

    Energy Technology Data Exchange (ETDEWEB)

    Hawari, Ayman I. [North Carolina State Univ., Raleigh, NC (United States); Ougouag, Abderrafi [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-01-22

    The objective of this project is to establish an approach for providing the fundamental input that is needed to estimate the magnitude and time-dependence of the Doppler feedback mechanism in Very High Temperature reactors. This mechanism is the foremost contributor to the passive safety of gas-cooled, graphite-moderated high temperature reactors that use fuel based on Tristructural-Isotropic (TRISO) coated particles. Therefore, its correct prediction is essential to the conduct of safety analyses for these reactors. Since the effect is directly dependent on the actual temperature reached by the fuel during transients, the underlying phenomena of heat deposition, heat transfer and temperature rise must be correctly predicted. To achieve the above objective, this project will explore an approach that accounts for lattice effects as well as local temperature variations and the correct definition of temperature and related local effects.

  10. Doppler time-of-flight imaging

    KAUST Repository

    Heidrich, Wolfgang

    2017-02-16

    Systems and methods for imaging object velocity are provided. In an embodiment, at least one Time-of-Flight camera is used to capture a signal representative of an object in motion over an exposure time. Illumination and modulation frequency of the captured motion are coded within the exposure time. A change of illumination frequency is mapped to measured pixel intensities of the captured motion within the exposure time, and information about a Doppler shift in the illumination frequency is extracted to obtain a measurement of instantaneous per pixel velocity of the object in motion. The radial velocity information of the object in motion can be simultaneously captured for each pixel captured within the exposure time. In one or more aspects, the illumination frequency can be coded orthogonal to the modulation frequency of the captured motion. The change of illumination frequency can correspond to radial object velocity.

  11. Analytic radar micro-Doppler signatures classification

    Science.gov (United States)

    Oh, Beom-Seok; Gu, Zhaoning; Wang, Guan; Toh, Kar-Ann; Lin, Zhiping

    2017-06-01

    Due to its capability of capturing the kinematic properties of a target object, radar micro-Doppler signatures (m-DS) play an important role in radar target classification. This is particularly evident from the remarkable number of research papers published every year on m-DS for various applications. However, most of these works rely on the support vector machine (SVM) for target classification. It is well known that training an SVM is computationally expensive due to its nature of search to locate the supporting vectors. In this paper, the classifier learning problem is addressed by a total error rate (TER) minimization where an analytic solution is available. This largely reduces the search time in the learning phase. The analytically obtained TER solution is globally optimal with respect to the classification total error count rate. Moreover, our empirical results show that TER outperforms SVM in terms of classification accuracy and computational efficiency on a five-category radar classification problem.

  12. Widefield laser doppler velocimeter: development and theory.

    Energy Technology Data Exchange (ETDEWEB)

    Hansche, Bruce David; Reu, Phillip L.; Massad, Jordan Elias

    2007-03-01

    The widefield laser Doppler velocimeter is a new measurement technique that significantly expands the functionality of a traditional scanning system. This new technique allows full-field velocity measurements without scanning, a drawback of traditional measurement techniques. This is particularly important for tests in which the sample is destroyed or the motion of the sample is non-repetitive. The goal of creating ''velocity movies'' was accomplished during the research, and this report describes the current functionality and operation of the system. The mathematical underpinnings and system setup are thoroughly described. Two prototype experiments are then presented to show the practical use of the current system. Details of the corresponding hardware used to collect the data and the associated software to analyze the data are presented.

  13. Ultrasonic intrusion sensor using the Doppler effect; Choonpa Doppler hoshiki shinnyu sensor

    Energy Technology Data Exchange (ETDEWEB)

    Kani, H.; Iwasaki, N.; Goto, M. [Nippon Soken, Inc., Tokyo (Japan); Tsuzuki, T.; Nakamura, T. [Denso Corp., Aichi (Japan)

    1997-10-01

    For vehicle anti-theft alarm systems which cope with vehicle and car component theft, EU initiated vehicle security regulations from Jan 1997. Also, the insurance industry has instituted the insurance certification of vehicle anti-theft alarm systems. We have developed an ultrasonic intrusion sensor using the doppler effect for vehicle anti-theft alarm systems specifically for these EU regulations and insurance certification. 2 refs., 7 figs., 1 tab.

  14. Laser Doppler flowmetry in endodontics: a review.

    Science.gov (United States)

    Jafarzadeh, H

    2009-06-01

    Vascular supply is the most accurate marker of pulp vitality. Tests for assessing vascular supply that rely on the passage of light through a tooth have been considered as possible methods for detecting pulp vitality. Laser Doppler flowmetry (LDF), which is a noninvasive, objective, painless, semi-quantitative method, has been shown to be reliable for measuring pulpal blood flow. The relevant literature on LDF in the context of endodontics up to March 2008 was reviewed using PubMed and MEDLINE database searches. This search identified papers published between June 1983 and March 2008. Laser light is transmitted to the pulp by means of a fibre optic probe. Scattered light from moving red blood cells will be frequency-shifted whilst that from the static tissue remains unshifted. The reflected light, composed of Doppler-shifted and unshifted light, is returned by afferent fibres and a signal is produced. This technique has been successfully employed for estimating pulpal vitality in adults and children, differential diagnosis of apical radiolucencies (on the basis of pulp vitality), examining the reactions to pharmacological agents or electrical and thermal stimulation, and monitoring of pulpal responses to orthodontic procedures and traumatic injuries. Assessments may be highly susceptible to environmental and technique-related factors. Nonpulpal signals, principally from periodontal blood flow, may contaminate the signal. Because this test produces no noxious stimuli, apprehensive or distressed patients accept it more readily than current methods of pulp vitality assessment. A review of the literature and a discussion of the application of this system in endodontics are presented.

  15. Surveillance and threat detection prevention versus mitigation

    CERN Document Server

    Kirchner, Richard

    2014-01-01

    Surveillance and Threat Detection offers readers a complete understanding of the terrorist/criminal cycle, and how to interrupt that cycle to prevent an attack. Terrorists and criminals often rely on pre-attack and pre-operational planning and surveillance activities that can last a period of weeks, months, or even years. Identifying and disrupting this surveillance is key to prevention of attacks. The systematic capture of suspicious events and the correlation of those events can reveal terrorist or criminal surveillance, allowing security professionals to employ appropriate countermeasures and identify the steps needed to apprehend the perpetrators. The results will dramatically increase the probability of prevention while streamlining protection assets and costs. Readers of Surveillance and Threat Detection will draw from real-world case studies that apply to their real-world security responsibilities. Ultimately, readers will come away with an understanding of how surveillance detection at a high-value, f...

  16. Use of Doppler ultrasound for non-invasive urodynamic diagnosis

    Directory of Open Access Journals (Sweden)

    Hideo Ozawa

    2009-01-01

    Full Text Available Objectives: A totally non-invasive transperineal urodynamic technique using Doppler ultrasonography has been developed. Methods: Since normal urine does not have blood cells, urine was thought not to produce the Doppler effects. However, basic studies confirmed that the decrease of pressure at high velocity (Bernouilli effect caused dissolved gas to form microbubbles, which are detected by Doppler ultrasonography. Subjects sat and the probe was advanced via remote control to achieve gentle contact with the perineal skin. The digital uroflow data signals and the color Doppler ultrasound video images were processed on a personal computer. The flow-velocity curves from two sites; the distal prostatic urethra just above the external sphincter (V1 and the sphincteric urethra (V2 were plotted against time. The parameters of both the pressure-flow studies and the Doppler ultrasound urodynamic studies were compared in men who had various degrees of obstruction. Results: Functional cross-sectional area at prostatic urethra (A1, calculated by Q max /V1, was lower in the group of bladder outlet obstruction (BOO vs. control group. Velocity ratio (VR, which was calculated by V1/V2, was the parameter having the best correlation with BOO index, though A1 had a similar correlation. This method is viable to diagnose the degree of BOO. Conclusions: The development of non-invasive Doppler ultrasound videourodynamics (Doppler UDS will dramatically expand the information on voiding function.

  17. Doppler sensitivity and its effect on transatlantic TWSTFT links

    Science.gov (United States)

    Zhang, Shengkang; Parker, Thomas; Zhang, Victor

    2017-02-01

    Some investigations have concluded that the diurnal pattern in the time comparison results of present two way satellite time and frequency transfer (TWSTFT) links may come mainly from Doppler dependent errors in the time of arrival (TOA) measurements made by the receivers of the TWSTFT modems. In this paper, several experiments were carried out to test if there is a Doppler dependent error in the ‘delay’ measurements of the receivers currently used. By simulating quantitative Doppler effects in the time transfer signal both on the carrier and the code, a type of Doppler sensitivity on the code was observed in the receivers, which has about  -0.49 ns offset in ‘delay’ measurement for a 1  ×  10-9 fractional Doppler shift. This sensitivity is basically the same for modems with different serial numbers from the same manufacture. We calculated this Doppler caused diurnal pattern in the time comparison results of the transatlantic TWSTFT link between NIST and PTB and found that it is very small and negligible, because the Doppler dependent error is almost identical in the NIST and PTB measurements and therefore it is nearly canceled in the TWSTFT difference. Commercial products are identified for technical completeness only, and no endorsement by NIST is implied.

  18. Ionospheric observations made by a time-interleaved Doppler ionosonde

    Science.gov (United States)

    Lynn, Kenneth J. W.

    2008-10-01

    Mid-latitude HF observations of ionospheric Doppler velocity as a function of frequency are reported here as observed over a quiet 24-h period by a KEL IPS71 ionosonde operating at a 5-min sampling rate. The unique time-interleaving technique used in this ionosonde provided a Doppler resolution of 0.04 Hz over a Doppler range of ±2.5 Hz at each sounding frequency via FFT processing and is described here for the first time. The time-interleaving technique can be applied to other types of ionosonde as well as to other applications. The measurements described were made at a middle latitude site (Salisbury, South Australia). Doppler variations (rate-of-change of foF2 as predicted by a simple parabolic layer model. The descending cusp in short-period TIDs is shown to mark an abrupt change with increasing frequency from negative towards positive Doppler shift with the greatest change in Doppler shift being observed below the cusp. The “smilergram” is introduced as observed in both F2 and Sporadic E. The characteristic curve in Doppler versus group height at a single frequency is described and related to changes in reflection symmetry, velocity and depth of moving ionospheric inhomogeneities.

  19. Platforms for Persistent Communications, Surveillance and Reconnaissance

    Science.gov (United States)

    2008-09-01

    Membership Study Manager Ms. Anorme Anim – ASB Communications (Comms) Team Dr. Allen Adler Dr. Pete Swan BG(Ret) Bob Wynn Ms. Madhu Beriwal Surveillance...Pete Swan BG(Ret) Bob Wynn Dr. Madhu Beriwal Surveillance & Reconnaissance (SR) Team Dr. Darrell Collier Mr. Herb Gallagher Mr. Gary Glaser Mr. Steve...ASB Communications (Comms) Team Dr. Allen Adler Dr. Pete Swan BG(Ret) Bob Wynn Ms. Madhu Beriwal Surveillance & Reconnaissance (SR) Team Dr

  20. Priorities for antibiotic resistance surveillance in Europe

    DEFF Research Database (Denmark)

    Fluit, A. C.; van der Bruggen, J. T.; Aarestrup, Frank Møller

    2006-01-01

    Antibiotic resistance is an increasing global problem. Surveillance studies are needed to monitor resistance development, to guide local empirical therapy, and to implement timely and adequate countermeasures. To achieve this, surveillance studies must have standardised methodologies...... to the various reservoirs of antibiotic-resistant bacteria, such as hospitalised patients, nursing homes, the community, animals and food. Two studies that could serve as examples of tailored programmes are the European Antimicrobial Resistance Surveillance System (EARSS), which collects resistance data during...... of antibiotic resistance....

  1. Pulsed Doppler echocardiographic analysis of mitral regurgitation after myocardial infarction.

    Science.gov (United States)

    Loperfido, F; Biasucci, L M; Pennestri, F; Laurenzi, F; Gimigliano, F; Vigna, C; Rossi, E; Favuzzi, A; Santarelli, P; Manzoli, U

    1986-10-01

    In 72 patients with previous myocardial infarction (MI), mitral regurgitation (MR) was assessed by pulsed-wave Doppler echocardiography and compared with physical and 2-dimensional echocardiographic findings. MR was found by Doppler in 29 of 42 patients (62%) with anterior MI, 11 of 30 (37%) with inferior MI (p less than 0.01) and in none of 20 normal control subjects. MR was more frequent in patients who underwent Doppler study 3 months after MI than in those who underwent Doppler at discharge (anterior MI = 83% vs 50%, p less than 0.01; inferior MI = 47% vs 27%, p = not significant). Of 15 patients who underwent Doppler studies both times, 3 (all with anterior MI) had MR only on the second study. Of the patients with Doppler MR, 12 of 27 (44%) with a left ventricular (LV) ejection fraction (EF) greater than 30% and 1 of 13 (8%) with an EF of 30% or less (p less than 0.01) had an MR systolic murmur. Mitral prolapse or eversion and papillary muscle fibrosis were infrequent in MI patients, whether or not Doppler MR was present. The degree of Doppler MR correlated with EF (r = -0.61), LV systolic volume (r = 0.47), and systolic and diastolic mitral anulus circumference (r = 0.52 and 0.51, respectively). Doppler MR was present in 24 of 28 patients (86%) with an EF of 40% or less and in 16 of 44 (36%) with EF more than 40% (p less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

  2. Limits on Planetary Companions from Doppler Surveys of Nearby Stars

    Science.gov (United States)

    Howard, Andrew W.; Fulton, Benjamin J.

    2016-11-01

    Most of our knowledge of planets orbiting nearby stars comes from Doppler surveys. For spaced-based, high-contrast imaging missions, nearby stars with Doppler-discovered planets are attractive targets. The known orbits tell imaging missions where and when to observe, and the dynamically determined masses provide important constraints for the interpretation of planetary spectra. Quantifying the set of planet masses and orbits that could have been detected will enable more efficient planet discovery and characterization. We analyzed Doppler measurements from Lick and Keck Observatories by the California Planet Survey. We focused on stars that are likely targets for three space-based planet imaging mission concepts studied by NASA—WFIRST-AFTA, Exo-C, and Exo-S. The Doppler targets are primarily F8 and later main sequence stars, with observations spanning 1987-2014. We identified 76 stars with Doppler measurements from the prospective mission target lists. We developed an automated planet search and a methodology to estimate the pipeline completeness using injection and recovery tests. We applied this machinery to the Doppler data and computed planet detection limits for each star as a function of planet minimum mass and semimajor axis. For typical stars in the survey, we are sensitive to approximately Saturn-mass planets inside of 1 au, Jupiter-mass planets inside of ˜3 au, and our sensitivity declines out to ˜10 au. For the best Doppler targets, we are sensitive to Neptune-mass planets in 3 au orbits. Using an idealized model of Doppler survey completeness, we forecast the precision of future surveys of non-ideal Doppler targets that are likely targets of imaging missions. Based on observations obtained at the W. M. Keck Observatory, which is operated jointly by the University of California and the California Institute of Technology. Keck time has been granted by NASA, the University of California, and the University of Hawaii.

  3. Medical surveillance of occupationally exposed workers

    Energy Technology Data Exchange (ETDEWEB)

    2007-05-15

    The guide covers medical surveillance of workers engaged in radiation work and their fitness for this work, protection of the foetus and infant during the worker's pregnancy or breastfeeding, and medical surveillance measures to be taken when the dose limit has been exceeded. The guide also covers recognition of practitioners responsible for medical surveillance of category A workers, medical certificates to be issued to workers, and preservation and transfer of medical records. The medical surveillance requirements specified in this Guide cover the use of radiation and nuclear energy. The guide also applies to exposure to natural radiation in accordance with section 28 of the Finnish Radiation Decree

  4. Remotely piloted LTA vehicle for surveillance

    Science.gov (United States)

    Seemann, G. R.; Harris, G. L.; Brown, G. J.

    1975-01-01

    Various aspects of a remotely piloted mini-LTA vehicle for surveillance, monitoring and measurement for civilian and military applications are considered. Applications, operations and economics are discussed.

  5. Carotid Doppler and transcranial Doppler in diagnosing transient ischemic attack: A healthy control

    Institute of Scientific and Technical Information of China (English)

    Huiling Chen; Jinhua Qiu; Hongying Liu

    2006-01-01

    BACKGROUND: If changes of hemodynamics in internal or external cranial artery and stenosis of atherosclerosis are found early, patients with transient ischemic attack (TIA) may be treated at an early phase so as to prevent and decrease the onset of cerebral infarction. Carotid Doppler can analyze carotid canal wall, hemodynamic properties and stenosis, and changes of plaque morphology; however, transcranial Doppler (TCD)can evaluate vascular stenosis and occlusion and judge collateral circulation in cranium through detecting velocity and direction of blood flow. Can the association of them increase the diagnostic rate of TIA?OBJECTIVE: To evaluate the effect of the association of carotid Doppler and TCD on TIA in internal carotid artery.DESIGN: Contrast observational study.SETTING: Department of Neuroelectrophysiology, Central People's Hospital of Huizhou.PARTICIPANTS: A total of 54 patients with TIA in internal carotid artery were selected from the Department of Neurology of Huizhou Central People's Hospital from May 2004 to June 2005. There were 35 males and 24 females aged 46-81 years. The clinical situation was asthenia of single limb, hemiplegia, anaesthesia of single upper or lower limb, hemianesthesia, sensory disorder and aphasia. The symptoms lasted for less than 2 hours. All cases were diagnosed with CT, and those who had pathological changes of acute cerebral infarction and history of cardiac disease were excluded. Additionally, 50 healthy subjects who were regarded as control group were selected from the Department of Neurology of Huizhou Central People's Hospital. There were 30 males and 20 females aged 45-80 years. All subjects were consent.METHODS: HD15000 color Doppler ultrasound (Philips Company, USA) and Muliti-DopX2 TCD (DWL Company, Germany) were used to detect hemodynamics, stenosis and distribution of atherosclerosis in carotid artery and internal carotid artery. Evaluation of marker: Stenosis was calculated by the ratio between the minimal

  6. Legionnaires’ disease Surveillance in Italy

    Directory of Open Access Journals (Sweden)

    Maria Luisa Ricci

    2004-12-01

    Full Text Available

    In the report presented, data on legionellosis diagnosed in the year 2003 in Italy and notified to the National Surveillance System are analysed. Overall, 617 cases were notified, of which 517 were confirmed and 46 were presumptive.

    The characteristics of the patients are very similar to those reported in the previous years in terms of male/female ratio, age–specific distribution, occupation, etc. Legionella pneumophila serogroup 1 was responsible for approximately 90% of the cases.

  7. Ultrasonic Doppler measurement of renal artery blood flow

    Science.gov (United States)

    Freund, W. R.; Beaver, W. L.; Meindl, J. D.

    1976-01-01

    Studies were made of (1) blood flow redistribution during lower body negative pressure (LBNP), (2) the profile of blood flow across the mitral annulus of the heart (both perpendicular and parallel to the commissures), (3) testing and evaluation of a number of pulsed Doppler systems, (4) acute calibration of perivascular Doppler transducers, (5) redesign of the mitral flow transducers to improve reliability and ease of construction, and (6) a frequency offset generator designed for use in distinguishing forward and reverse components of blood flow by producing frequencies above and below the offset frequency. Finally methodology was developed and initial results were obtained from a computer analysis of time-varying Doppler spectra.

  8. Interferometric millimeter wave and THz wave doppler radar

    Science.gov (United States)

    Liao, Shaolin; Gopalsami, Nachappa; Bakhtiari, Sasan; Raptis, Apostolos C.; Elmer, Thomas

    2015-08-11

    A mixerless high frequency interferometric Doppler radar system and methods has been invented, numerically validated and experimentally tested. A continuous wave source, phase modulator (e.g., a continuously oscillating reference mirror) and intensity detector are utilized. The intensity detector measures the intensity of the combined reflected Doppler signal and the modulated reference beam. Rigorous mathematics formulas have been developed to extract bot amplitude and phase from the measured intensity signal. Software in Matlab has been developed and used to extract such amplitude and phase information from the experimental data. Both amplitude and phase are calculated and the Doppler frequency signature of the object is determined.

  9. Processor operated correlator with applications to laser Doppler signals

    DEFF Research Database (Denmark)

    Bisgaard, C.; Johnsen, B.; Hassager, Ole

    1984-01-01

    A 64-channel correlator is designed with application to the processing of laser Doppler anemometry signals in the range 200 Hz to 250 kHz. The correlator is processor operated to enable the consecutive sampling of 448 correlation functions at a rate up to 500 Hz. Software is described to identify...... a Doppler frequency from each correlation and the system is especially designed for transient flow signals. Doppler frequencies are determined with an accuracy of about 0.1%. Review of Scientific Instruments is copyrighted by The American Institute of Physics....

  10. Mitigating Doppler shift effect in HF multitone data modem

    Science.gov (United States)

    Sonlu, Yasar

    1989-09-01

    Digital communications over High Frequency (HF) radio channels are getting important in recent years. Current HF requirements are for data transmission at rates 2.4 kbps or more to accommodate computer data links and digital secure voice. HF modems which were produced to meet these speeds are, serial modems and parallel modems. On the other hand, the HF sky-wave communication medium, the ionosphere, has some propagation problems such as multipath and Doppler shift. The effect of Doppler shift in a parallel modem which employs Differential Quadrature Phase Shift Keying (DQPSK) modulation is considered and a correction method to mitigate the Doppler Shift effect is introduced.

  11. Computer simulation studies of pulsed Doppler signals from vortices

    Institute of Scientific and Technical Information of China (English)

    CHEN Sizhong; WANG Yuanyuan; WANG Weiqi

    2001-01-01

    A computer simulation method for pulsed Doppler signals from vortices was proposed to generate simulated vortex Doppler signals under various given circumstances. The relative waveforms, such as the maximum frequency waveform, the mean frequency waveform and the bandwidth waveform, were obtained using the short time Fourier analysis of those simulated signals. The relations were studied between several spectrum parameters obtained from these waveforms and given simulation conditions, such as the position and the size of the sample volume, the distance between two vortices, the free stream velocity and the maximum tangent velocity of the vortex. The sensitive parameters were found to detect vortices using the pulsed Doppler techniques.

  12. Automatic extraction of disease-specific features from Doppler images

    Science.gov (United States)

    Negahdar, Mohammadreza; Moradi, Mehdi; Parajuli, Nripesh; Syeda-Mahmood, Tanveer

    2017-03-01

    Flow Doppler imaging is widely used by clinicians to detect diseases of the valves. In particular, continuous wave (CW) Doppler mode scan is routinely done during echocardiography and shows Doppler signal traces over multiple heart cycles. Traditionally, echocardiographers have manually traced such velocity envelopes to extract measurements such as decay time and pressure gradient which are then matched to normal and abnormal values based on clinical guidelines. In this paper, we present a fully automatic approach to deriving these measurements for aortic stenosis retrospectively from echocardiography videos. Comparison of our method with measurements made by echocardiographers shows large agreement as well as identification of new cases missed by echocardiographers.

  13. Limits on surveillance: frictions, fragilities and failures in the operation of camera surveillance.

    NARCIS (Netherlands)

    Dubbeld, L.

    2004-01-01

    Public video surveillance tends to be discussed in either utopian or dystopian terms: proponents maintain that camera surveillance is the perfect tool in the fight against crime, while critics argue that the use of security cameras is central to the development of a panoptic, Orwellian surveillance

  14. Limits on surveillance: frictions, fragilities and failures in the operation of camera surveillance.

    NARCIS (Netherlands)

    Dubbeld, Lynsey

    2004-01-01

    Public video surveillance tends to be discussed in either utopian or dystopian terms: proponents maintain that camera surveillance is the perfect tool in the fight against crime, while critics argue that the use of security cameras is central to the development of a panoptic, Orwellian surveillance

  15. The Next Generation Airborne Polarimetric Doppler Radar

    Science.gov (United States)

    Vivekanandan, J.; Lee, Wen-Chau; Loew, Eric; Salazar, Jorge; Chandrasekar, V.

    2013-04-01

    NCAR's Electra Doppler radar (ELDORA) with a dual-beam slotted waveguide array using dual-transmitter, dual-beam, rapid scan and step-chirped waveform significantly improved the spatial scale to 300m (Hildebrand et al. 1996). However, ELDORA X-band radar's penetration into precipitation is limited by attenuation and is not designed to collect polarimetric measurements to remotely estimate microphysics. ELDORA has been placed on dormancy because its airborne platform (P3 587) was retired in January 2013. The US research community has strongly voiced the need to continue measurement capability similar to the ELDORA. A critical weather research area is quantitative precipitation estimation/forecasting (QPE/QPF). In recent years, hurricane intensity change involving eye-eyewall interactions has drawn research attention (Montgomery et al., 2006; Bell and Montgomery, 2006). In the case of convective precipitation, two issues, namely, (1) when and where convection will be initiated, and (2) determining the organization and structure of ensuing convection, are key for QPF. Therefore collocated measurements of 3-D winds and precipitation microphysics are required for achieving significant skills in QPF and QPE. Multiple radars in dual-Doppler configuration with polarization capability estimate dynamical and microphysical characteristics of clouds and precipitation are mostly available over land. However, storms over complex terrain, the ocean and in forest regions are not observable by ground-based radars (Bluestein and Wakimoto, 2003). NCAR/EOL is investigating potential configurations for the next generation airborne radar that is capable of retrieving dynamic and microphysical characteristics of clouds and precipitation. ELDORA's slotted waveguide array radar is not compatible for dual-polarization measurements. Therefore, the new design has to address both dual-polarization capability and platform requirements to replace the ELDORA system. NCAR maintains a C-130

  16. Cyber Surveillance for Flood Disasters

    Directory of Open Access Journals (Sweden)

    Shi-Wei Lo

    2015-01-01

    Full Text Available Regional heavy rainfall is usually caused by the influence of extreme weather conditions. Instant heavy rainfall often results in the flooding of rivers and the neighboring low-lying areas, which is responsible for a large number of casualties and considerable property loss. The existing precipitation forecast systems mostly focus on the analysis and forecast of large-scale areas but do not provide precise instant automatic monitoring and alert feedback for individual river areas and sections. Therefore, in this paper, we propose an easy method to automatically monitor the flood object of a specific area, based on the currently widely used remote cyber surveillance systems and image processing methods, in order to obtain instant flooding and waterlogging event feedback. The intrusion detection mode of these surveillance systems is used in this study, wherein a flood is considered a possible invasion object. Through the detection and verification of flood objects, automatic flood risk-level monitoring of specific individual river segments, as well as the automatic urban inundation detection, has become possible. The proposed method can better meet the practical needs of disaster prevention than the method of large-area forecasting. It also has several other advantages, such as flexibility in location selection, no requirement of a standard water-level ruler, and a relatively large field of view, when compared with the traditional water-level measurements using video screens. The results can offer prompt reference for appropriate disaster warning actions in small areas, making them more accurate and effective.

  17. Health surveillance and endocrine disruptors

    Directory of Open Access Journals (Sweden)

    Waissmann William

    2002-01-01

    Full Text Available The author discusses the extreme relevance of research on the presence of endocrine disruptors (EDs in products of interest to health surveillance (HS. Focusing on EDs, the author highlights the urgency of changes already under way in the direction of HS. The shift should be from product and product-registration approaches to the productive process and its realization in consumption, generation of contaminants, and alterations in the health of workers and the overall population. He briefly describes: regulatory gaps for dealing with EDs; difficulty in evaluating risk and suspension of the production and use of products with its characteristics and the need, as exemplified by such products, to enhance the inter-relationship among all stakeholders and to turn HS into a state-of-the-art technological setting, associated with the academic community and accountable to the public. The author reports on measures already taken in relation to EDs, including the establishment of a reference laboratory for analyzing persistent organic pollutants (POPs, interruption of the use of various POPs in Brazil and an initial review of requirements for registering pesticides under the Brazilian National Health Surveillance Agency (ANVISA.

  18. Health surveillance and endocrine disruptors

    Directory of Open Access Journals (Sweden)

    William Waissmann

    2002-04-01

    Full Text Available The author discusses the extreme relevance of research on the presence of endocrine disruptors (EDs in products of interest to health surveillance (HS. Focusing on EDs, the author highlights the urgency of changes already under way in the direction of HS. The shift should be from product and product-registration approaches to the productive process and its realization in consumption, generation of contaminants, and alterations in the health of workers and the overall population. He briefly describes: regulatory gaps for dealing with EDs; difficulty in evaluating risk and suspension of the production and use of products with its characteristics and the need, as exemplified by such products, to enhance the inter-relationship among all stakeholders and to turn HS into a state-of-the-art technological setting, associated with the academic community and accountable to the public. The author reports on measures already taken in relation to EDs, including the establishment of a reference laboratory for analyzing persistent organic pollutants (POPs, interruption of the use of various POPs in Brazil and an initial review of requirements for registering pesticides under the Brazilian National Health Surveillance Agency (ANVISA.

  19. Estimation of amputation level with a laser Doppler flowmeter

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Jørgensen, J P; Vollmer-Larsen, B;

    1989-01-01

    Leg amputation levels were decided in 24 patients suffering from atherosclerosis, using the conventional techniques of segmental blood pressure and radioisotope skin clearance. The skin microcirculation was measured and recorded before operation with a laser doppler flowmeter. A high correlation ...

  20. Doppler Signatures of the Atmospheric Circulation on Hot Jupiters

    CERN Document Server

    Showman, Adam P; Lewis, Nikole K; Shabram, Megan

    2013-01-01

    The meteorology of hot Jupiters has been characterized primarily with thermal measurements, but recent observations suggest the possibility of directly detecting the winds by observing the Doppler shift of spectral lines seen during transit. Motivated by these observations, we show how Doppler measurements can place powerful constraints on the meteorology. We show that the atmospheric circulation--and Doppler signature--of hot Jupiters splits into two regimes. Under weak stellar insolation, the day-night thermal forcing generates fast zonal jet streams from the interaction of atmospheric waves with the mean flow. In this regime, air along the terminator (as seen during transit) flows toward Earth in some regions and away from Earth in others, leading to a Doppler signature exhibiting superposed blue- and redshifted components. Under intense stellar insolation, however, the strong thermal forcing damps these planetary-scale waves, inhibiting their ability to generate jets. Strong frictional drag likewise damps...

  1. Doppler bubble detection and decompression sickness: a prospective clinical trial.

    Science.gov (United States)

    Bayne, C G; Hunt, W S; Johanson, D C; Flynn, E T; Weathersby, P K

    1985-09-01

    Decompression sickness in human beings exposed to high ambient pressure is thought to follow from gas bubble formation and growth in the body during return to low pressure. Detection of Doppler-shifted ultrasonic reflections in major blood vessels has been promoted as a noninvasive and sensitive indicator of the imminence of decompression sickness. We have conducted a double-blind, prospective clinical trial of Doppler ultrasonic bubble detection in simulated diving using 83 men, of whom 8 were stricken and treated for the clinical disease. Diagnosis based only on the Doppler signals had no correlation with clinical diagnosis. Bubble scores were only slightly higher in the stricken group. The Doppler technique does not appear to be of diagnostic value in the absence of other clinical information.

  2. Doppler electron velocimetry : notes on creating a practical tool.

    Energy Technology Data Exchange (ETDEWEB)

    Reu, Phillip L.; Milster, Tom (University of Arizona)

    2008-11-01

    The Doppler electron velocimeter (DEV) has been shown to be theoretically possible. This report attempts to answer the next logical question: Is it a practical instrument? The answer hinges upon whether enough electrons are available to create a time-varying Doppler current to be measured by a detector with enough sensitivity and bandwidth. The answer to both of these questions is a qualified yes. A target Doppler frequency of 1 MHz was set as a minimum rate of interest. At this target a theoretical beam current signal-to-noise ratio of 25-to-1 is shown for existing electron holography equipment. A detector is also demonstrated with a bandwidth of 1-MHz at a current of 10 pA. Additionally, a Linnik-type interferometer that would increase the available beam current is shown that would offer a more flexible arrangement for Doppler electron measurements over the traditional biprism.

  3. Aliasing-tolerant color Doppler quantification of regurgitant jets.

    Science.gov (United States)

    Stewart, S F

    1998-07-01

    Conservation of momentum transfer in regurgitant cardiac jets can be used to calculate the flow rate from color Doppler velocities. In this study, turbulent jets were simulated by finite elements; pseudocolor Doppler images were interpolated from the computations, with aliasing introduced artificially. Jets were also imaged by color Doppler in an in vitro flow system. To suppress aliasing errors, jet velocities were fitted iteratively to a fluid mechanical model constrained to match the orifice velocity (measured without aliasing by continuous-wave Doppler). At each iteration, the model was used to detect aliased velocities, which were excluded during the next iteration. Iteration continued until the flow rate calculated by the model and number of calculated nonaliased pixels were unchanged. The good correlations between measured and calculated flow rates in the experimental (R2 = 0.933) and computational studies (R2 = 0.990) suggest that this may be a clinically useful approach even in aliased images. Published by Elsevier Science Inc.

  4. Micro-Doppler processing for ultra-wideband radar data

    Science.gov (United States)

    Smith, Graeme E.; Ahmad, Fauzia; Amin, Moeness G.

    2012-06-01

    In this paper, we describe an operational pulse Doppler radar imaging system for indoor target localization and classification, and show how a target's micro-Doppler signature (μDS) can be processed when ultra-wideband (UWB) waveforms are employed. Unlike narrowband radars where time-frequency signal representations can be applied to reveal the target time-Doppler frequency signatures, the UWB system permits joint range-time-frequency representation (JRTFR). JRTFR outputs the data in a 3D domain representing range, frequency, and time, allowing both the μDS and high range resolution (HRR) signatures to be observed. We delineate the relationship between the μDS and the HRR signature, showing how they would form a complimentary joint feature for classification. We use real-data to demonstrate the effectiveness of the UWB pulse-Doppler radar, combined with nonstationary signal analyses, in gaining valuable insights into human positioning and motions.

  5. Millimeter-wave micro-Doppler measurements of small UAVs

    Science.gov (United States)

    Rahman, Samiur; Robertson, Duncan A.

    2017-05-01

    This paper discusses the micro-Doppler signatures of small UAVs obtained from a millimeter-wave radar system. At first, simulation results are shown to demonstrate the theoretical concept. It is illustrated that whilst the propeller rotation rate of the small UAVs is quite high, millimeter-wave radar systems are capable of capturing the full micro-Doppler spread. Measurements of small UAVs have been performed with both CW and FMCW radars operating at 94 GHz. The CW radar was used for obtaining micro-Doppler signatures of individual propellers. The field test data of a flying small UAV was collected with the FMCW radar and was processed to extract micro-Doppler signatures. The high fidelity results clearly reveal features such as blade flashes and propeller rotation modulation lines which can be used to classify targets. This work confirms that millimeter-wave radar is suitable for the detection and classification of small UAVs at usefully long ranges.

  6. Extracting and analyzing micro-Doppler from ladar signatures

    Science.gov (United States)

    Tahmoush, Dave

    2015-05-01

    Ladar and other 3D imaging modalities have the capability of creating 3D micro-Doppler to analyze the micro-motions of human subjects. An additional capability to the recognition of micro-motion is the recognition of the moving part, such as the hand or arm. Combined with measured RCS values of the body, ladar imaging can be used to ground-truth the more sensitive radar micro-Doppler measurements and associate the moving part of the subject with the measured Doppler and RCS from the radar system. The 3D ladar signatures can also be used to classify activities and actions on their own, achieving an 86% accuracy using a micro-Doppler based classification strategy.

  7. The Doppler Effect: A Consideration of Quasar Redshifts.

    Science.gov (United States)

    Gordon, Kurtiss J.

    1980-01-01

    Provides information on the calculation of the redshift to blueshift ratio introduced by the transverse Doppler effect at relativistic speeds. Indicates that this shift should be mentioned in discussions of whether quasars are "local" rather than "cosmological" objects. (GS)

  8. Doppler Ambiguity Resolution Based on Random Sparse Probing Pulses

    Directory of Open Access Journals (Sweden)

    Yunjian Zhang

    2015-01-01

    Full Text Available A novel method for solving Doppler ambiguous problem based on compressed sensing (CS theory is proposed in this paper. A pulse train with the random and sparse transmitting time is transmitted. The received signals after matched filtering can be viewed as randomly sparse sampling from the traditional fixed-pulse repetition frequency (PRF echo signals. The whole target echo could be reconstructed via CS recovery algorithms. Through refining the sensing matrix, which is equivalent to increase the sampling frequency of target characteristic, the Doppler unambiguous range is enlarged. In particular, Complex Approximate Message Passing (CAMP algorithm is developed to estimate the unambiguity Doppler frequency. Cramer-Rao lower bound expressions are derived for the frequency. Numerical simulations validate the effectiveness of the proposed method. Finally, compared with traditional methods, the proposed method only requires transmitting a few sparse probing pulses to achieve a larger Doppler frequency unambiguous range and can also reduce the consumption of the radar time resources.

  9. [Postpartal ovarian thrombophlebitis. Value of Doppler ultrasonograph y].

    Science.gov (United States)

    Renaud-Giono, A; Giraud, J R; Poulain, P; Proudhon, J F; Grall, J Y; Moquet, P Y; Darnault, J P

    1996-01-01

    Thrombophlebitis of the ovarian vein is a well recognized but uncommon complication during the postpartum period. We report a small series and emphasize the contribution of color Doppler and the basic therapeutic measures.

  10. Doppler ultrasound exam of an arm or leg

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003775.htm Doppler ultrasound exam of an arm or leg To use ... this page, please enable JavaScript. This test uses ultrasound to look at the blood flow in the ...

  11. Analysis of multiple scattering effects in optical Doppler tomography

    DEFF Research Database (Denmark)

    Yura, H.T.; Thrane, L.; Andersen, Peter E.

    2005-01-01

    Optical Doppler tomography (ODT) combines Doppler velocimetry and optical coherence tomography (OCT) to obtain high-resolution cross-sectional imaging of particle flow velocity in scattering media such as the human retina and skin. Here, we present the results of a theoretical analysis of ODT where...... multiple scattering effects are included. The purpose of this analysis is to determine how multiple scattering affects the estimation of the depth-resolved localized flow velocity. Depth-resolved velocity estimates are obtained directly from the corresponding mean or standard deviation of the observed...... Doppler frequency spectrum. Thus, in the present analysis, the dependence of the mean and standard deviation of the Doppler shift on the scattering properties of the flowing medium are obtained. Taking the multiple scattering effects into account, we are able to explain previous measurements of depth...

  12. Multiplexed sub-Doppler spectroscopy with an optical frequency comb

    CERN Document Server

    Long, David A; Plusquellic, David F; Hodges, Joseph T

    2016-01-01

    An optical frequency comb generated with an electro-optic phase modulator and a chirped radiofrequency waveform is used to perform saturation and pump-probe spectroscopy on the $D_1$ and $D_2$ transitions of atomic potassium. With a comb tooth spacing of 200 kHz and an optical bandwidth of 2 GHz the hyperfine transitions can be simultaneously observed. Interferograms are recorded in as little as 5 $\\mu$s (a timescale corresponding to the inverse of the comb tooth spacing). Importantly, the sub-Doppler features can be measured as long as the laser carrier frequency lies within the Doppler profile, thus removing the need for slow scanning or a priori knowledge of the frequencies of the sub-Doppler features. Sub-Doppler optical frequency comb spectroscopy has the potential to dramatically reduce acquisition times and allow for rapid and accurate assignment of complex molecular and atomic spectra which are presently intractable.

  13. COLOR DOPPLER ULTRASOUND IN EVALUATION OF SCROTAL LESIONS

    Directory of Open Access Journals (Sweden)

    Desai Sanjay

    2015-11-01

    Full Text Available : Color Doppler ultrasound is a non-invasive, non-ionising and rapid method for scrotal examination. The present study is carried out to evaluate clinically suspected cases of scrotal lesions, the sensitivity, specificity of color doppler. MATERIAL AND METHODS: This prospective study comprises 120 patients of different age groups with clinical suspicion of scrotal lesions. Color doppler ultrasound was done with 7.5MHz transducer. RESULTS: Of the total 120 cases, benign conditions 111 (92.5% is more common than malignant 9 (7.5%. In benign group commonest diagnoses were hydrocele, epididymo-orchitis, varicocele and epididymal cyst. In malignant group teratocarcinoma, choriocarcinoma, seminoma, lymphoma, embryonal cell carcinoma, yolk sac tumor with teratocarcinoma. The sensitivity for diagnosing extratesticular lesions was 83.14% and for testicular lesions 88.57%. CONCLUSION: Color doppler ultrasound is helpful in differentiating extratesticular and intratesticular lesions. It should be performed in all patients with suspected scrotal lesions

  14. The Doppler Effect: A Consideration of Quasar Redshifts.

    Science.gov (United States)

    Gordon, Kurtiss J.

    1980-01-01

    Provides information on the calculation of the redshift to blueshift ratio introduced by the transverse Doppler effect at relativistic speeds. Indicates that this shift should be mentioned in discussions of whether quasars are "local" rather than "cosmological" objects. (GS)

  15. Design of new seismometer based on laser Doppler effect

    Institute of Scientific and Technical Information of China (English)

    Zhenhui Du(杜振辉); Fuxiang Huang(黄福祥); Chengzhi Jiang(蒋诚志); Zhifei Tao(陶知非); Hua Gao(高华); Lina Lü(吕丽娜)

    2004-01-01

    In order to improve the resolution of seismic acquisition, a new seismic acquisition system based on tangential laser Doppler effect with an optimized differential optical configuration is proposed. The relative movement of the inertia object and the immobile frame is measured by laser Doppler effect, which can avoid the electromagnetic and thermometric interference, and the adoption of frequency-modulated (FM)transmission can improve the ability of anti-jamming. The frequency bandwidth is properly determined by analyzing the frequency of the Doppler signal. The velocity, displacement, acceleration, and frequency to be measured can be real-time acquired by frequency/velocity (F/V) converting the FM Doppler signal.A 100-dB dynamic range and the linear frequency range of 1.0 to 1000 Hz are realized.

  16. Doppler Compensation by using of Segmented Match Filter

    Directory of Open Access Journals (Sweden)

    Nader Ghadimi

    2008-09-01

    Full Text Available Match filter is one of the important parts of radar receiver. By using of Match Filter, the signal to noise ratio can be maximized so that the probability of detection is increased. Match Filter can be used as a pulse compression filter in radar receiver. Binary phase code is one of the pulse compression methods that, the compression can be down with a Match Filter in the receiver. Doppler effect is one of the problems that degrade the performance of Match Filter. In this paper, two methods “Mixer Array” and “Segmented Match Filter” are proposed for Doppler compensation. The operation of these two methods as Doppler compensation techniques are considered theoretically. The simulation is used to demonstrate the Doppler compensation performance of new techniques compared to conventional methods.

  17. Methodology for obtaining wind gusts using Doppler lidar

    DEFF Research Database (Denmark)

    Suomi, Irene; Gryning, Sven-Erik; O'Connor, Ewan J.

    2017-01-01

    . This novel method also provides estimates for wind gusts at arbitrary gust durations, including those shorter than the temporal resolution of the Doppler lidar measurements. The input parameters for the scaling method are the measured wind-gust speed as well as the mean and standard deviation...... of the horizontal wind speed. The method was tested using WindCube V2 Doppler lidar measurements taken next to a 100 m high meteorological mast. It is shown that the method can provide realistic Doppler lidar estimates of the gust factor, i.e. the ratio of the wind-gust speed to the mean wind speed. The method...... speed. To assure the data quality in this study, we applied a filtering technique based on spike detection to remove possible outliers in the Doppler lidar data. We found that the spike detection-removal method clearly improved the wind-gust measurements, both with and without the scaling method. Spike...

  18. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Maulik, D. [Winthrop Univ. Hospital, Mineola, NY (United States). Dept. of Obstetrics and Gynecology; Zalud, I. (eds.) [Kapiolani Medical Center for Women and Children, Honolulu, HI (United States)

    2005-07-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  19. 40 CFR 52.2030 - Source surveillance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Source surveillance. 52.2030 Section 52.2030 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) Pennsylvania § 52.2030 Source surveillance...

  20. European surveillance network for influenza in pigs

    NARCIS (Netherlands)

    Simon, Gaëlle; Larsen, Lars E.; Dürrwald, Ralf; Foni, Emanuela; Harder, Timm; Reeth, Van Kristien; Markowska-Daniel, Iwona; Reid, Scott M.; Dan, Adam; Maldonado, Jaime; Huovilainen, Anita; Billinis, Charalambos; Davidson, Irit; Agüero, Montserrat; Vila, Thaïs; Hervé, Séverine; Breum, Solvej Østergaard; Chiapponi, Chiara; Urbaniak, Kinga; Kyriakis, Constantinos S.; Brown, Ian H.; Loeffen, Willie; Meulen, Van der Karen; Schlegel, Michael; Bublot, Michel; Kellam, Paul; Watson, Simon; Lewis, Nicola S.; Pybus, Oliver G.; Webby, Richard; Chen, Hualan; Vincent, Amy L.

    2014-01-01

    Swine influenza causes concern for global veterinary and public health officials. In continuing two previous networks that initiated the surveillance of swine influenza viruses (SIVs) circulating in European pigs between 2001 and 2008, a third European Surveillance Network for Influenza in Pigs (

  1. Rare disease surveillance: An international perspective

    NARCIS (Netherlands)

    Elliott, E.J.; Nicoll, A.; Lynn, R.; Marchessault, V.; Hirasing, R.A.; Ridley, G.

    2001-01-01

    Background: The International Network of Paediatric Surveillance Units (INoPSU) was established in 1998 and met formally for the first time in Ottawa, Ontario in June 2000. Objectives: To document the methodology and activities of existing national paediatric surveillance units; the formation of

  2. Unattended video surveillance systems for international safeguards

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, C.S.

    1979-01-01

    The use of unattended video surveillance systems places some unique requirements on the systems and their hardware. The systems have the traditional requirements of video imaging, video storage, and video playback but also have some special requirements such as tamper safing. The technology available to meet these requirements and how it is being applied to unattended video surveillance systems are discussed in this paper.

  3. Rare disease surveillance: An international perspective

    NARCIS (Netherlands)

    Elliott, E.J.; Nicoll, A.; Lynn, R.; Marchessault, V.; Hirasing, R.A.; Ridley, G.

    2001-01-01

    Background: The International Network of Paediatric Surveillance Units (INoPSU) was established in 1998 and met formally for the first time in Ottawa, Ontario in June 2000. Objectives: To document the methodology and activities of existing national paediatric surveillance units; the formation of INo

  4. Video Surveillance: All Eyes Turn to IP

    Science.gov (United States)

    Raths, David

    2011-01-01

    Many university officials recognize the need to upgrade their older analog video surveillance systems. In a 2010 survey by "Campus Safety" magazine, half of university respondents expressed dissatisfaction with the quality and coverage of their current video surveillance systems. Among the limitations of analog closed-circuit television…

  5. Quantification of cardiac blood flow by Doppler technique

    OpenAIRE

    Meijboom, Erik Jan

    1985-01-01

    textabstractThe investigations described in this thesis started as part of the research program of the divisions of pediatric cardiology of the Universities of Arizona and California (San Diego). The investigations were part of an ongoing project designed by D.J. Sahn and L.M. Valdes-Cruz. This project was initiated to implement Doppler techniques in the daily practice of pediatric cardiology. New developments in medical technology made the Doppler techniques integrated into sophisticated two...

  6. Monitoring and Analysis of Respiratory Patterns Using Microwave Doppler Radar

    Science.gov (United States)

    Pathirana, Pubudu N.; Steinfort, Christopher Louis; Caelli, Terry

    2014-01-01

    Noncontact detection characteristic of Doppler radar provides an unobtrusive means of respiration detection and monitoring. This avoids additional preparations, such as physical sensor attachment or special clothing, which can be useful for certain healthcare applications. Furthermore, robustness of Doppler radar against environmental factors, such as light, ambient temperature, interference from other signals occupying the same bandwidth, fading effects, reduce environmental constraints and strengthens the possibility of employing Doppler radar in long-term respiration detection, and monitoring applications such as sleep studies. This paper presents an evaluation in the of use of microwave Doppler radar for capturing different dynamics of breathing patterns in addition to the respiration rate. Although finding the respiration rate is essential, identifying abnormal breathing patterns in real-time could be used to gain further insights into respiratory disorders and refine diagnostic procedures. Several known breathing disorders were professionally role played and captured in a real-time laboratory environment using a noncontact Doppler radar to evaluate the feasibility of this noncontact form of measurement in capturing breathing patterns under different conditions associated with certain breathing disorders. In addition to that, inhalation and exhalation flow patterns under different breathing scenarios were investigated to further support the feasibility of Doppler radar to accurately estimate the tidal volume. The results obtained for both experiments were compared with the gold standard measurement schemes, such as respiration belt and spirometry readings, yielding significant correlations with the Doppler radar-based information. In summary, Doppler radar is highlighted as an alternative approach not only for determining respiration rates, but also for identifying breathing patterns and tidal volumes as a preferred nonwearable alternative to the conventional

  7. Radar target recognition based on micro-Doppler effect

    Institute of Scientific and Technical Information of China (English)

    DONG Wei-guang; LI Yan-jun

    2008-01-01

    Mechanical vibration of target structures will modulate the phase function of radar backscattering, and will induce thefrequency modulation of returned signals from the target. It generates a side bands of the target body Doppler frequencyshift, which is helpful for target recognition. Based on this.a micro-Doppler atomic storehouse is built for the targetrecognition, and four kinds of common classifiers are used separately to perform the classified recognition. The simulationexperimental results show that this method has high recognition rate above 90%.

  8. Using doppler radar images to estimate aircraft navigational heading error

    Science.gov (United States)

    Doerry, Armin W [Albuquerque, NM; Jordan, Jay D [Albuquerque, NM; Kim, Theodore J [Albuquerque, NM

    2012-07-03

    A yaw angle error of a motion measurement system carried on an aircraft for navigation is estimated from Doppler radar images captured using the aircraft. At least two radar pulses aimed at respectively different physical locations in a targeted area are transmitted from a radar antenna carried on the aircraft. At least two Doppler radar images that respectively correspond to the at least two transmitted radar pulses are produced. These images are used to produce an estimate of the yaw angle error.

  9. Single mode, extreme precision Doppler spectrographs

    CERN Document Server

    Schwab, Christian; Betters, Christopher H; Bland-Hawthorn, Joss; Mahadevan, Suvrath

    2012-01-01

    The 'holy grail' of exoplanet research today is the detection of an earth-like planet: a rocky planet in the habitable zone around a main-sequence star. Extremely precise Doppler spectroscopy is an indispensable tool to find and characterize earth-like planets; however, to find these planets around solar-type stars, we need nearly one order of magnitude better radial velocity (RV) precision than the best current spectrographs provide. Recent developments in astrophotonics (Bland-Hawthorn & Horton 2006, Bland-Hawthorn et al. 2010) and adaptive optics (AO) enable single mode fiber (SMF) fed, high resolution spectrographs, which can realize the next step in precision. SMF feeds have intrinsic advantages over multimode fiber or slit coupled spectrographs: The intensity distribution at the fiber exit is extremely stable, and as a result the line spread function of a well-designed spectrograph is fully decoupled from input coupling conditions, like guiding or seeing variations (Ihle et al. 2010). Modal noise, a...

  10. Satellite Doppler Fixation and International Boundaries

    Science.gov (United States)

    Leppard, N. A. G.

    1980-01-01

    International boundaries have seldom been completely defined in geodetic terms. The existence of natural resources, which ignore the arbitrary boundaries of man, assume considerable importance when division of those resources becomes a point of issue between potential owners. This is particularly so when the boundary is illdefined in a geodetic sense. World-wide satellite reference systems, like natural resources, also have little regard for the internally less precise national or international systems. When the one is used to define the location of the other, great care must be taken to ensure equitable division, for financial gain and loss can be considerable. The definition of position is complicated by the existence of the two ephemerides for the N.N.S.S. satellites and the number of alternative reduction procedures available. The definition of the position of the Frigg Gas Field in the North Sea is an example of how the United Kingdom and Norway resolved the geodetic problem of reconciling geodetic and Doppler data.

  11. Doppler time-of-flight imaging

    KAUST Repository

    Heide, Felix

    2015-07-30

    Over the last few years, depth cameras have become increasingly popular for a range of applications, including human-computer interaction and gaming, augmented reality, machine vision, and medical imaging. Many of the commercially-available devices use the time-of-flight principle, where active illumination is temporally coded and analyzed on the camera to estimate a per-pixel depth map of the scene. In this paper, we propose a fundamentally new imaging modality for all time-of-flight (ToF) cameras: per-pixel velocity measurement. The proposed technique exploits the Doppler effect of objects in motion, which shifts the temporal frequency of the illumination before it reaches the camera. Using carefully coded illumination and modulation frequencies of the ToF camera, object velocities directly map to measured pixel intensities. We show that a slight modification of our imaging system allows for color, depth, and velocity information to be captured simultaneously. Combining the optical flow computed on the RGB frames with the measured metric axial velocity allows us to further estimate the full 3D metric velocity field of the scene. We believe that the proposed technique has applications in many computer graphics and vision problems, for example motion tracking, segmentation, recognition, and motion deblurring.

  12. Doppler cooling of a Coulomb crystal

    CERN Document Server

    Morigi, G; Morigi, Giovanna; Eschner, Juergen

    2001-01-01

    We study theoretically Doppler laser-cooling of a cluster of 2-level atoms confined in a linear ion trap. Using several consecutive steps of averaging we derive, from the full quantum mechanical master equation, an equation for the total mechanical energy of the one dimensional crystal, defined on a coarse-grained energy scale whose grid size is smaller than the linewidth of the electronic transition. This equation describes the cooling dynamics for an arbitrary number of ions and in the quantum regime. We discuss the validity of the ergodic assumption (i.e. that the phase space distribution is only a function of energy). From our equation we derive the semiclassical limit (i.e. when the mechanical motion can be treated classically) and the Lamb-Dicke limit (i.e. when the size of the mechanical wave function is much smaller than the laser wavelength). We find a Fokker-Planck equation for the total mechanical energy of the system, whose solution is in agreement with previous analytical calculations which were ...

  13. MEMS characterization using Laser Doppler Vibrometry

    Science.gov (United States)

    Lawrence, Eric M.; Speller, Kevin E.; Yu, Duli

    2003-01-01

    The use of Laser Doppler Vibrometry (LDV) technology has been at the forefront of Micro-Electro-Mechanical Systems (MEMS) research since the early 1990"s. By its nature as a sensitive laser optical technique, it is well suited for non-contact dynamic response measurements of microscopic structures. The art of the technology has culminated into the latest micro-scanning vibrometer for automated scan measurement and display of deflection shapes with sub-nanometer resolution. To exemplify the use of this technology, Polytec PI presents characterization measurements in collaboration with Applied MEMS on two of their devices used in commercial applications. LDV characterization measurements are used for validating the design of the Applied MEMS two-axis micro mirror. Scan measurements reveal distinct, isolated rotation modes about x- and y- axes that can be used to promote the mirror motion in either direction. Settling time performance is evaluated from impulse response and optimized using Input Shaping techniques. Scan measurements of a low-noise accelerometer device from Applied MEMS reveals spurious high frequency modes of support spring causing unwanted response effects. Further use of a new time domain animation feature shows ringing response of the accelerometer to step motions.

  14. Muscle activity characterization by laser Doppler Myography

    Science.gov (United States)

    Scalise, Lorenzo; Casaccia, Sara; Marchionni, Paolo; Ercoli, Ilaria; Primo Tomasini, Enrico

    2013-09-01

    Electromiography (EMG) is the gold-standard technique used for the evaluation of muscle activity. This technique is used in biomechanics, sport medicine, neurology and rehabilitation therapy and it provides the electrical activity produced by skeletal muscles. Among the parameters measured with EMG, two very important quantities are: signal amplitude and duration of muscle contraction, muscle fatigue and maximum muscle power. Recently, a new measurement procedure, named Laser Doppler Myography (LDMi), for the non contact assessment of muscle activity has been proposed to measure the vibro-mechanical behaviour of the muscle. The aim of this study is to present the LDMi technique and to evaluate its capacity to measure some characteristic features proper of the muscle. In this paper LDMi is compared with standard superficial EMG (sEMG) requiring the application of sensors on the skin of each patient. sEMG and LDMi signals have been simultaneously acquired and processed to test correlations. Three parameters has been analyzed to compare these techniques: Muscle activation timing, signal amplitude and muscle fatigue. LDMi appears to be a reliable and promising measurement technique allowing the measurements without contact with the patient skin.

  15. Doppler effect induced spin relaxation boom

    Science.gov (United States)

    Zhao, Xinyu; Huang, Peihao; Hu, Xuedong

    2016-03-01

    We study an electron spin qubit confined in a moving quantum dot (QD), with our attention on both spin relaxation, and the product of spin relaxation, the emitted phonons. We find that Doppler effect leads to several interesting phenomena. In particular, spin relaxation rate peaks when the QD motion is in the transonic regime, which we term a spin relaxation boom in analogy to the classical sonic boom. This peak indicates that a moving spin qubit may have even lower relaxation rate than a static qubit, pointing at the possibility of coherence-preserving transport for a spin qubit. We also find that the emitted phonons become strongly directional and narrow in their frequency range as the qubit reaches the supersonic regime, similar to Cherenkov radiation. In other words, fast moving excited spin qubits can act as a source of non-classical phonons. Compared to classical Cherenkov radiation, we show that quantum dot confinement produces a small but important correction on the Cherenkov angle. Taking together, these results have important implications to both spin-based quantum information processing and coherent phonon dynamics in semiconductor nanostructures.

  16. Zeeman Doppler Maps: Always Unique, Never Spurious?

    Science.gov (United States)

    Stift, Martin J.; Leone, Francesco

    2017-01-01

    Numerical models of atomic diffusion in magnetic atmospheres of ApBp stars predict abundance structures that differ from the empirical maps derived with (Zeeman) Doppler mapping (ZDM). An in-depth analysis of this apparent disagreement investigates the detectability by means of ZDM of a variety of abundance structures, including (warped) rings predicted by theory, but also complex spot-like structures. Even when spectra of high signal-to-noise ratio are available, it can prove difficult or altogether impossible to correctly recover shapes, positions, and abundances of a mere handful of spots, notwithstanding the use of all four Stokes parameters and an exactly known field geometry; the recovery of (warped) rings can be equally challenging. Inversions of complex abundance maps that are based on just one or two spectral lines usually permit multiple solutions. It turns out that it can by no means be guaranteed that any of the regularization functions in general use for ZDM (maximum entropy or Tikhonov) will lead to a true abundance map instead of some spurious one. Attention is drawn to the need for a study that would elucidate the relation between the stratified, field-dependent abundance structures predicted by diffusion theory on the one hand, and empirical maps obtained by means of “canonical” ZDM, i.e., with mean atmospheres and unstratified abundances, on the other hand. Finally, we point out difficulties arising from the three-dimensional nature of the atomic diffusion process in magnetic ApBp star atmospheres.

  17. Intrahepatic portosystemic venous shunts: diagnosis by Doppler ultrasound; Cortocircuitos venosos portosistemicos intrahepaticos: diagnostico mediante ecografia Doppler

    Energy Technology Data Exchange (ETDEWEB)

    Garofano, M. P.; Medina, A.; Lopez, G.; Garrido, C. [Hospital Universitario Virgen de las Nieves. Granada (Spain)

    2001-07-01

    Intrahepatic portosystemic venous shunts are venous vascular lesions that allow intrahepatic portal vessels to communicate with hepatic veins. They may present in patients with portal hypertension or b discovered incidentally; it is considered that the latter may be congenital or acquired. A noninvasive methods. Doppler ultrasound aids in the diagnosis of these anomalous communications by providing images of the vessels and the direction, velocity and volume of the blood flow through the shunt. We present four cases of intrahepatic portosystemic venous shunt. (Author) 8 refs.

  18. Low-Frequency Gravitational Wave Searches Using Spacecraft Doppler Tracking

    Directory of Open Access Journals (Sweden)

    Armstrong J. W.

    2006-01-01

    Full Text Available This paper discusses spacecraft Doppler tracking, the current-generation detector technology used in the low-frequency (~millihertz gravitational wave band. In the Doppler method the earth and a distant spacecraft act as free test masses with a ground-based precision Doppler tracking system continuously monitoring the earth-spacecraft relative dimensionless velocity $2 Delta v/c = Delta u/ u_0$, where $Delta u$ is the Doppler shift and $ u_0$ is the radio link carrier frequency. A gravitational wave having strain amplitude $h$ incident on the earth-spacecraft system causes perturbations of order $h$ in the time series of $Delta u/ u_0$. Unlike other detectors, the ~1-10 AU earth-spacecraft separation makes the detector large compared with millihertz-band gravitational wavelengths, and thus times-of-flight of signals and radio waves through the apparatus are important. A burst signal, for example, is time-resolved into a characteristic signature: three discrete events in the Doppler time series. I discuss here the principles of operation of this detector (emphasizing transfer functions of gravitational wave signals and the principal noises to the Doppler time series, some data analysis techniques, experiments to date, and illustrations of sensitivity and current detector performance. I conclude with a discussion of how gravitational wave sensitivity can be improved in the low-frequency band.

  19. Doppler Monitoring of the WASP-47 Multiplanet System

    CERN Document Server

    Dai, Fei; Arriagada, Pamela; Butler, R Paul; Crane, Jeffrey D; Johnson, John Asher; Shectman, Stephen A; Teske, Johanna K; Thompson, Ian B; Vanderburg, Andrew; Wittenmyer, Robert A

    2015-01-01

    We present precise Doppler observations of WASP-47, a transiting planetary system featuring a hot Jupiter with both inner and outer planetary companions. This system has an unusual architecture and also provides a rare opportunity to measure planet masses in two different ways: the Doppler method, and the analysis of transit-timing variations (TTV). Based on the new Doppler data, obtained with the Planet Finder Spectrograph on the Magellan/Clay 6.5m telescope, the mass of the hot Jupiter is $370 \\pm 29~M_{\\oplus}$. This is consistent with the previous Doppler determination as well as the TTV determination. For the inner planet WASP-47e, the Doppler data lead to a mass of $12.2\\pm 3.7~ M_{\\oplus}$, in agreement with the TTV-based upper limit of $<$22~$M_{\\oplus}$ ($95\\%$ confidence). For the outer planet WASP-47d, the Doppler mass constraint of $10.4\\pm 8.4~M_{\\oplus}$ is consistent with the TTV-based measurement of $15.2^{+6.7}_{-7.6}~ M_{\\oplus}$.

  20. Analysis of Radar Doppler Signature from Human Data

    Directory of Open Access Journals (Sweden)

    M. ANDRIĆ

    2014-04-01

    Full Text Available This paper presents the results of time (autocorrelation and time-frequency (spectrogram analyses of radar signals returned from the moving human targets. When a radar signal falls on the human target which is moving toward or away from the radar, the signals reflected from different parts of his body produce a Doppler shift that is proportional to the velocity of those parts. Moving parts of the body causes the characteristic Doppler signature. The main contribution comes from the torso which causes the central Doppler frequency of target. The motion of arms and legs induces modulation on the returned radar signal and generates sidebands around the central Doppler frequency, referred to as micro-Doppler signatures. Through analyses on experimental data it was demonstrated that the human motion signature extraction is better using spectrogram. While the central Doppler frequency can be determined using the autocorrelation and the spectrogram, the extraction of the fundamental cadence frequency using the autocorrelation is unreliable when the target is in the clutter presence. It was shown that the fundamental cadence frequency increases with increasing dynamic movement of people and simultaneously the possibility of its extraction is proportional to the degree of synchronization movements of persons in the group.

  1. Microbiological Food Safety Surveillance in China

    Directory of Open Access Journals (Sweden)

    Xiaoyan Pei

    2015-08-01

    Full Text Available Microbiological food safety surveillance is a system that collects data regarding food contamination by foodborne pathogens, parasites, viruses, and other harmful microbiological factors. It helps to understand the spectrum of food safety, timely detect food safety hazards, and provide relevant data for food safety supervision, risk assessment, and standards-setting. The study discusses the microbiological surveillance of food safety in China, and introduces the policies and history of the national microbiological surveillance system. In addition, the function and duties of different organizations and institutions are provided in this work, as well as the generation and content of the surveillance plan, quality control, database, and achievement of the microbiological surveillance of food safety in China.

  2. Microbiological Food Safety Surveillance in China.

    Science.gov (United States)

    Pei, Xiaoyan; Li, Ning; Guo, Yunchang; Liu, Xiumei; Yan, Lin; Li, Ying; Yang, Shuran; Hu, Jing; Zhu, Jianghui; Yang, Dajin

    2015-08-28

    Microbiological food safety surveillance is a system that collects data regarding food contamination by foodborne pathogens, parasites, viruses, and other harmful microbiological factors. It helps to understand the spectrum of food safety, timely detect food safety hazards, and provide relevant data for food safety supervision, risk assessment, and standards-setting. The study discusses the microbiological surveillance of food safety in China, and introduces the policies and history of the national microbiological surveillance system. In addition, the function and duties of different organizations and institutions are provided in this work, as well as the generation and content of the surveillance plan, quality control, database, and achievement of the microbiological surveillance of food safety in China.

  3. Classification and modeling of human activities using empirical mode decomposition with S-band and millimeter-wave micro-Doppler radars

    Science.gov (United States)

    Fairchild, Dustin P.; Narayanan, Ram M.

    2012-06-01

    The ability to identify human movements can be an important tool in many different applications such as surveillance, military combat situations, search and rescue operations, and patient monitoring in hospitals. This information can provide soldiers, security personnel, and search and rescue workers with critical knowledge that can be used to potentially save lives and/or avoid a dangerous situation. Most research involving human activity recognition is focused on using the Short-Time Fourier Transform (STFT) as a method of analyzing the micro-Doppler signatures. Because of the time-frequency resolution limitations of the STFT and because Fourier transform-based methods are not well-suited for use with non-stationary and nonlinear signals, we have chosen a different approach. Empirical Mode Decomposition (EMD) has been shown to be a valuable time-frequency method for processing non-stationary and nonlinear data such as micro-Doppler signatures and EMD readily provides a feature vector that can be utilized for classification. For classification, the method of a Support Vector Machine (SVMs) was chosen. SVMs have been widely used as a method of pattern recognition due to their ability to generalize well and also because of their moderately simple implementation. In this paper, we discuss the ability of these methods to accurately identify human movements based on their micro-Doppler signatures obtained from S-band and millimeter-wave radar systems. Comparisons will also be made based on experimental results from each of these radar systems. Furthermore, we will present simulations of micro-Doppler movements for stationary subjects that will enable us to compare our experimental Doppler data to what we would expect from an "ideal" movement.

  4. Calculation of the Doppler broadening function using Fourier analysis;Calculo da funcao de alargamento Doppler utilizando analise de Fourier

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, Alessandro da Cruz

    2010-07-01

    An efficient and precise method for calculation of Doppler broadening function is very important to obtain average group microscopic cross sections, self shielding factors, resonance integrals and others reactor physics parameter. In this thesis two different methods for calculation of Doppler broadening function and interference term will be presented. The main method is based on a new integral form for Doppler broadening function {psi}(x,{zeta}) which gives a mathematical interpretation of the approximation proposed by Bethe and Placzek, as the convolution of the Lorentzian function with a Gaussian function. This interpretation besides leading to a new integral form for {psi}(x,{zeta}), enables to obtain a simple analytic solution for the Doppler broadening function. (author)

  5. Automatic Dependent Surveillance - Broadcast Verification and Validation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Automatic Dependent Surveillance ? Broadcast (ADS-B) is an emerging Communications, Navigation, and Surveillance (CNS) technology that will vastly expand the state...

  6. The Nordic Obstetric Surveillance Study

    DEFF Research Database (Denmark)

    Colmorn, Lotte B.; Petersen, Kathrine B; Jakobsson, Maija

    2015-01-01

    OBJECTIVE: To assess the rates and characteristics of women with complete uterine rupture, abnormally invasive placenta, peripartum hysterectomy, and severe blood loss at delivery in the Nordic countries. DESIGN: Prospective, Nordic collaboration. SETTING: The Nordic Obstetric Surveillance Study...... (NOSS) collected cases of severe obstetric complications in the Nordic countries from April 2009 to August 2012. SAMPLE AND METHODS: Cases were reported by clinicians at the Nordic maternity units and retrieved from medical birth registers, hospital discharge registers, and transfusion databases...... hysterectomy was 3.5/10 000 deliveries. Of the women, 25% had two or more complications. Women with complications were more often >35 years old, overweight, with a higher parity, and a history of cesarean delivery compared with the total population. CONCLUSION: The studied obstetric complications are rare...

  7. Symbolic power, robotting, and surveilling

    DEFF Research Database (Denmark)

    Skovsmose, Ole

    2012-01-01

    Symbolic power is discussed with reference to mathematics and formal languages. Two distinctions are crucial for establishing mechanical and formal perspectives: one between appearance and reality, and one between sense and reference. These distinctions include a nomination of what to consider...... primary and secondary. They establish the grammatical format of a mechanical and a formal world view. Such views become imposed on the domains addressed by means of mathematics and formal languages. Through such impositions symbolic power of mathematics becomes exercised. The idea that mathematics...... describes as it prioritises is discussed with reference to robotting and surveillance. In general, the symbolic power of mathematics and formal languages is summarised through the observations: that mathematics treats parts and properties as autonomous, that it dismembers what it addresses and destroys...

  8. [Ethical problems in health surveillance].

    Science.gov (United States)

    Toffoletto, F; Briatico Vangosa, G; Panizza, C

    2000-01-01

    Surveillance of workers' health in the field of occupational medicine poses substantial ethical problems in view of occupational medicine's complex responsibilities towards workers and employers, preventive and protection services, workers' representatives, public healthcare and preventive medicine facilities, controlling agencies and judicial authorities. Potentially conflicting rights and duties often come into play in this sector. In the last few years various international and national bodies have drawn up codes of ethics or guidelines for the conduct of physicians in occupational medicine, three of which are of particular importance: 1) The International Ethical Code of the International Commission on Occupational Health (ICOH, 1992); 2) The Code of Conduct of the National Association of Company Doctors (ANMA, 1997); 3) The Technical and Ethical Guidelines for workers' health (ILO, 1998). The chief purpose of all these documents is to safeguard the health of workers and to guarantee the safety of the workplace by defining programmes of health supervision to match specific risks. The methods should be non-invasive and should allow for a check or efficiency. The physician is expected to have a high degree of professionalism and up-to-date skills; to be independent and impartial; to be reserved and capable of inter-disciplinary co-operation. On the basis of the above documents, a number of problematic aspects may be appraised concerning the relationship between the occupational health physician responsible for the surveillance activities of the local health authority and the relative company physician. The documents stress the importance of keeping up to date and of quality, fields in which the dominant role played by Scientific Societies is underlined. Finally it is recommended that health supervision be arranged in such a manner as to foster the professionalism and responsibility of the physician in charge rather than the formal implementation of health

  9. Fpga based L-band pulse doppler radar design and implementation

    Science.gov (United States)

    Savci, Kubilay

    As its name implies RADAR (Radio Detection and Ranging) is an electromagnetic sensor used for detection and locating targets from their return signals. Radar systems propagate electromagnetic energy, from the antenna which is in part intercepted by an object. Objects reradiate a portion of energy which is captured by the radar receiver. The received signal is then processed for information extraction. Radar systems are widely used for surveillance, air security, navigation, weather hazard detection, as well as remote sensing applications. In this work, an FPGA based L-band Pulse Doppler radar prototype, which is used for target detection, localization and velocity calculation has been built and a general-purpose Pulse Doppler radar processor has been developed. This radar is a ground based stationary monopulse radar, which transmits a short pulse with a certain pulse repetition frequency (PRF). Return signals from the target are processed and information about their location and velocity is extracted. Discrete components are used for the transmitter and receiver chain. The hardware solution is based on Xilinx Virtex-6 ML605 FPGA board, responsible for the control of the radar system and the digital signal processing of the received signal, which involves Constant False Alarm Rate (CFAR) detection and Pulse Doppler processing. The algorithm is implemented in MATLAB/SIMULINK using the Xilinx System Generator for DSP tool. The field programmable gate arrays (FPGA) implementation of the radar system provides the flexibility of changing parameters such as the PRF and pulse length therefore it can be used with different radar configurations as well. A VHDL design has been developed for 1Gbit Ethernet connection to transfer digitized return signal and detection results to PC. An A-Scope software has been developed with C# programming language to display time domain radar signals and detection results on PC. Data are processed both in FPGA chip and on PC. FPGA uses fixed

  10. Longitudinal study of aortic isthmus Doppler in appropriately grown and small-for-gestational-age fetuses with normal and abnormal umbilical artery Doppler.

    LENUS (Irish Health Repository)

    Kennelly, M M

    2012-04-01

    To establish reference ranges using longitudinal data for aortic isthmus (AoI) Doppler indices in appropriate-for-gestational-age (AGA) fetuses and to document the longitudinal trends in a cohort of small-for-gestational-age (SGA) fetuses with normal umbilical artery Doppler and in fetuses with intrauterine growth restriction (IUGR) and abnormal umbilical artery Doppler.

  11. ADEPT - Abnormal Doppler Enteral Prescription Trial

    Directory of Open Access Journals (Sweden)

    McCormick Kenny

    2009-10-01

    Full Text Available Abstract Background Pregnancies complicated by abnormal umbilical artery Doppler blood flow patterns often result in the baby being born both preterm and growth-restricted. These babies are at high risk of milk intolerance and necrotising enterocolitis, as well as post-natal growth failure, and there is no clinical consensus about how best to feed them. Policies of both early milk feeding and late milk feeding are widely used. This randomised controlled trial aims to determine whether a policy of early initiation of milk feeds is beneficial compared with late initiation. Optimising neonatal feeding for this group of babies may have long-term health implications and if either of these policies is shown to be beneficial it can be immediately adopted into clinical practice. Methods and Design Babies with gestational age below 35 weeks, and with birth weight below 10th centile for gestational age, will be randomly allocated to an "early" or "late" enteral feeding regimen, commencing milk feeds on day 2 and day 6 after birth, respectively. Feeds will be gradually increased over 9-13 days (depending on gestational age using a schedule derived from those used in hospitals in the Eastern and South Western Regions of England, based on surveys of feeding practice. Primary outcome measures are time to establish full enteral feeding and necrotising enterocolitis; secondary outcomes include sepsis and growth. The target sample size is 400 babies. This sample size is large enough to detect a clinically meaningful difference of 3 days in time to establish full enteral feeds between the two feeding policies, with 90% power and a 5% 2-sided significance level. Initial recruitment period was 24 months, subsequently extended to 38 months. Discussion There is limited evidence from randomised controlled trials on which to base decisions regarding feeding policy in high risk preterm infants. This multicentre trial will help to guide clinical practice and may also

  12. Doppler ultrasound and giant cell arteritis

    Directory of Open Access Journals (Sweden)

    Ana Marina Suelves

    2010-11-01

    Full Text Available Ana Marina Suelves1, Enrique España-Gregori1,2, Jose Tembl3, Stephanie Rohrweck1, Jose Maria Millán4, Manuel Díaz-Llopis1,4,51Service of Ophthalmology, La Fe University Hospital, Valencia, Spain; 2Department of Optics, University of Valencia, Valencia, Spain; 3Service of Neurology, La Fe University Hospital, Valencia, Spain; 4CIBERER, Ciber de Enfermedades Raras, Valencia, Spain; 5Faculty of Medicine, University of Valencia, Valencia, SpainObjective: To evaluate the utility of ultrasound in aiding the diagnosis of giant cell arteritis (GCA, in monitoring the response to corticotherapy, and in detecting early relapses.Methods: A pilot study, prospective, included 10 patients with suspected GCA. All patients underwent ultrasound examination of both temporal arteries before temporal artery biopsy (TAB, 3 weeks after starting treatment, and 3 months after diagnosis. For this study, the histological findings alone were used to define if patients were suffering from GCA. The findings on ultrasound were compared with the results of biopsy. The best place to perform TAB was observed by ultrasound.Results: All patients with positive biopsy were detected with ultrasound. No false positives were observed on ultrasound. The results presented give a sensibility, specificity, and positive predictive value of 100% for the use of ultrasound in the diagnosis of GCA. Two relapses were detected early by ultrasound during the follow-up.Conclusions: This pilot study suggests that eco-doppler may be a useful tool in diagnosis and clinic follow-up in patients with suspected GCA.Keywords: giant cell arteritis, ultrasound, temporal artery biopsy, optic nerve

  13. Single Mode, Extreme Precision Doppler Spectrographs

    Science.gov (United States)

    Schwab, Christian; Leon-Saval, Sergio G.; Betters, Christopher H.; Bland-Hawthorn, Joss; Mahadevan, Suvrath

    2014-04-01

    The `holy grail' of exoplanet research today is the detection of an earth-like planet: a rocky planet in the habitable zone around a main-sequence star. Extremely precise Doppler spectroscopy is an indispensable tool to find and characterize earth-like planets; however, to find these planets around solar-type stars, we need nearly one order of magnitude better radial velocity (RV) precision than the best current spectrographs provide. Recent developments in astrophotonics (Bland-Hawthorn & Horton 2006, Bland-Hawthorn et al. 2010) and adaptive optics (AO) enable single mode fiber (SMF) fed, high resolution spectrographs, which can realize the next step in precision. SMF feeds have intrinsic advantages over multimode fiber or slit coupled spectrographs: The intensity distribution at the fiber exit is extremely stable, and as a result the line spread function of a well-designed spectrograph is fully decoupled from input coupling conditions, like guiding or seeing variations (Ihle et al. 2010). Modal noise, a limiting factor in current multimode fiber fed instruments (Baudrand & Walker 2001), can be eliminated by proper design, and the diffraction limited input to the spectrograph allows for very compact instrument designs, which provide excellent optomechanical stability. A SMF is the ideal interface for new, very precise wavelength calibrators, like laser frequency combs (Steinmetz et al. 2008, Osterman et al. 2012), or SMF based Fabry-Perot Etalons (Halverson et al. 2013). At near infrared wavelengths, these technologies are ready to be implemented in on-sky instruments, or already in use. We discuss a novel concept for such a spectrograph.

  14. Interpreting laser Doppler recordings from free flaps.

    Science.gov (United States)

    Svensson, H; Holmberg, J; Svedman, P

    1993-01-01

    Although the transfer of free flaps is nowadays accomplished with an increasing degree of safety, thrombosis of the microvascular anastomoses is still a problem. In order to avoid delay in re-operating, various methods for objective blood flow monitoring have been tried, among them Laser Doppler Flowmetry (LDF). When one reviews the literature, it is apparent that opinions differ about whether or not LDF is a reliable technique for this purpose. To focus on the need to interpret continuous recordings, this paper reports our findings in six latissimus dorsi free flaps chosen from our series of LDF monitoring procedures. One uneventful flap, no. 1, had an immediate postoperative LDF value of 4.5 perfusion units (PU). LDF values improved during the recovery period and the graphic recording showed fluctuations due to normal physiological variations of the blood flow in the flap. Another uneventful flap, no. 4, showed the same pattern, though at an appreciably lower level, 2 PU, on average. Flap no. 2 had an acceptably high value of 3.5 PU despite suffering a venous thrombosis. However, the LDF recording showed no fluctuations and the value declined gradually. Another flap, no. 3, showed fluctuations and blood flow was normal although the value decreased to 2.5 PU. In flap no. 5, any value between 2 and 3.5 PU could be obtained merely by adjusting the position of the probe in the holder. In no. 6, the LDF value suddenly dropped, accompanied by a decrease in the total amount of backscattered light, indicating venous obstruction which was confirmed at re-operation.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Cost effectiveness of surveillance for GI cancers.

    Science.gov (United States)

    Omidvari, Amir-Houshang; Meester, Reinier G S; Lansdorp-Vogelaar, Iris

    2016-12-01

    Gastrointestinal (GI) diseases are among the leading causes of death in the world. To reduce the burden of GI diseases, surveillance is recommended for some diseases, including for patients with inflammatory bowel diseases, Barrett's oesophagus, precancerous gastric lesions, colorectal adenoma, and pancreatic neoplasms. This review aims to provide an overview of the evidence on cost-effectiveness of surveillance of individuals with GI conditions predisposing them to cancer, specifically focussing on the aforementioned conditions. We searched the literature and reviewed 21 studies. Despite heterogeneity of studies in terms of settings, study populations, surveillance strategies and outcomes, most reviewed studies suggested at least some surveillance of patients with these GI conditions to be cost-effective. For some high-risk conditions frequent surveillance with 3-month intervals was warranted, while for other conditions, surveillance may only be cost-effective every 10 years. Further studies based on more robust effectiveness evidence are needed to inform and optimise surveillance programmes for GI cancers. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Remote container monitoring and surveillance systems

    Energy Technology Data Exchange (ETDEWEB)

    Resnik, W.M.; Kadner, S.P. [Aquila Technologies Group, Inc., Albuquerque, NM (United States)

    1995-12-31

    Aquila Technologies Group is developing a monitoring and surveillance system to monitor containers of nuclear materials. The system will both visually and physically monitor the containers. The system is based on the combination of Aquila`s Gemini All-Digital Surveillance System and on Aquila`s AssetLAN{trademark} asset tracking technology. This paper discusses the Gemini Digital Surveillance system as well as AssetLAN technology. The Gemini architecture with emphasis on anti-tamper security features is also described. The importance of all-digital surveillance versus other surveillance methods is also discussed. AssetLAN{trademark} technology is described, emphasizing the ability to continually track containers (as assets) by location utilizing touch memory technology. Touch memory technology provides unique container identification, as well as the ability to store and retrieve digital information on the container. This information may relate to container maintenance, inspection schedules, and other information. Finally, this paper describes the combination of the Gemini system with AssetLAN technology, yielding a self contained, container monitoring and area/container surveillance system. Secure container fixture design considerations are discussed. Basic surveillance review functions are also discussed.

  17. Modernization of existing VVER-1000 surveillance programs

    Energy Technology Data Exchange (ETDEWEB)

    Kochkin, V.; Erak, D.; Makhotin, D. [NRC ' Kurchatov Inst.' , 1 Kurchatov Square, Moscow 123182 (Russian Federation)

    2011-07-01

    According to generally accepted world practice, evaluation of the reactor pressure vessel (RPV) material behavior during operation is carried out using tests of surveillance specimens. The main objective of the surveillance program consists in insurance of safe RPV operation during the design lifetime and lifetime-extension period. At present, the approaches of pressure vessels residual life validation based on the test results of their surveillance specimens have been developed and introduced in Russia and are under consideration in other countries where vodo-vodyanoi energetichesky reactors- (VVER-) 1000 are in operation. In this case, it is necessary to ensure leading irradiation of surveillance specimens (as compared to the pressure vessel wall) and to provide uniformly irradiated specimen groups for mechanical testing. Standard surveillance program of VVER-1000 has several significant shortcomings and does not meet these requirements. Taking into account program of lifetime extension of VVER-1000 operating in Russia, it is necessary to carry out upgrading of the VVER-1000 surveillance program. This paper studies the conditions of a surveillance specimen's irradiation and upgrading of existing sets to provide monitoring and prognosis of RPV material properties for extension of the reactor's lifetime up to 60 years or more. (authors)

  18. Standardized rendering from IR surveillance motion imagery

    Science.gov (United States)

    Prokoski, F. J.

    2014-06-01

    Government agencies, including defense and law enforcement, increasingly make use of video from surveillance systems and camera phones owned by non-government entities.Making advanced and standardized motion imaging technology available to private and commercial users at cost-effective prices would benefit all parties. In particular, incorporating thermal infrared into commercial surveillance systems offers substantial benefits beyond night vision capability. Face rendering is a process to facilitate exploitation of thermal infrared surveillance imagery from the general area of a crime scene, to assist investigations with and without cooperating eyewitnesses. Face rendering automatically generates greyscale representations similar to police artist sketches for faces in surveillance imagery collected from proximate locations and times to a crime under investigation. Near-realtime generation of face renderings can provide law enforcement with an investigation tool to assess witness memory and credibility, and integrate reports from multiple eyewitnesses, Renderings can be quickly disseminated through social media to warn of a person who may pose an immediate threat, and to solicit the public's help in identifying possible suspects and witnesses. Renderings are pose-standardized so as to not divulge the presence and location of eyewitnesses and surveillance cameras. Incorporation of thermal infrared imaging into commercial surveillance systems will significantly improve system performance, and reduce manual review times, at an incremental cost that will continue to decrease. Benefits to criminal justice would include improved reliability of eyewitness testimony and improved accuracy of distinguishing among minority groups in eyewitness and surveillance identifications.

  19. DOPPLER SIGNATURES OF THE ATMOSPHERIC CIRCULATION ON HOT JUPITERS

    Energy Technology Data Exchange (ETDEWEB)

    Showman, Adam P.; Lewis, Nikole K. [Department of Planetary Sciences and Lunar and Planetary Laboratory, The University of Arizona, 1629 University Boulevard, Tucson, AZ 85721 (United States); Fortney, Jonathan J. [Department of Astronomy and Astrophysics, University of California, Santa Cruz, CA 95064 (United States); Shabram, Megan, E-mail: showman@lpl.arizona.edu [Department of Astronomy, University of Florida, 211 Bryant Space Science Center, Gainesville, FL 32611-2055 (United States)

    2013-01-01

    The meteorology of hot Jupiters has been characterized primarily with thermal measurements, but recent observations suggest the possibility of directly detecting the winds by observing the Doppler shift of spectral lines seen during transit. Motivated by these observations, we show how Doppler measurements can place powerful constraints on the meteorology. We show that the atmospheric circulation-and Doppler signature-of hot Jupiters splits into two regimes. Under weak stellar insolation, the day-night thermal forcing generates fast zonal jet streams from the interaction of atmospheric waves with the mean flow. In this regime, air along the terminator (as seen during transit) flows toward Earth in some regions and away from Earth in others, leading to a Doppler signature exhibiting superposed blueshifted and redshifted components. Under intense stellar insolation, however, the strong thermal forcing damps these planetary-scale waves, inhibiting their ability to generate jets. Strong frictional drag likewise damps these waves and inhibits jet formation. As a result, this second regime exhibits a circulation dominated by high-altitude, day-to-night airflow, leading to a predominantly blueshifted Doppler signature during transit. We present state-of-the-art circulation models including non-gray radiative transfer to quantify this regime shift and the resulting Doppler signatures; these models suggest that cool planets like GJ 436b lie in the first regime, HD 189733b is transitional, while planets hotter than HD 209458b lie in the second regime. Moreover, we show how the amplitude of the Doppler shifts constrains the strength of frictional drag in the upper atmospheres of hot Jupiters. If due to winds, the {approx}2 km s{sup -1} blueshift inferred on HD 209458b may require drag time constants as short as 10{sup 4}-10{sup 6} s, possibly the result of Lorentz-force braking on this planet's hot dayside.

  20. Application of IR microbolometers in border surveillance

    Science.gov (United States)

    Breakfield, David K.; Norton, Peter; Plemons, Dan; Rodriguez, Christian; Sustare, Dennis

    2007-04-01

    BAE Systems led a collaborative study with New Mexico State University to investigate a series of ground based persistent surveillance solutions for potential use along the Southwest border of the United States. This study considered a wide range of system options for mobile and fixed site applications. This paper summarizes the findings of the study including the central role of the imaging subsystems in mobile ground based surveillance solutions and the suitability of uncooled IR Microbolometers within this subsystem. The paper also provides a discussion of the benefits of real time decision support applications when fielding a persistent surveillance solution.

  1. The value of micro-Doppler in stereotactic brain biopsy.

    Science.gov (United States)

    Hertel, F; Feiden, W; Bettag, M

    2005-06-01

    The aim of this study was to analyse the value of intraoperative micro-Doppler in stereotactic brain biopsy (SBB). So far, only a few studies have reported about the usefulness of micro-Doppler in stereotactic brain biopsy. Between 1998 and 2003, 155 SBBs were performed in 153 patients with micro-Doppler (81 males, 72 females, mean age: 59 years). All operations were performed using a ZD-frame and a multiplanar computer tomography-guided trajectory planning system (Leibinger SPP). A 16 MHz micro-Doppler probe (diameter 1 mm, DWL) was used in all cases to explore the area of biopsy before the tissue probes were taken. Serial biopsies (mean, 6 samples) were taken with the Sedan side-cutting cannula (n = 145) or the small forceps (n = 10). We evaluated the number of intraoperative detectable vessel signals by micro-Doppler, intraoperative bleedings as well as bleedings detected by postoperative CT (which was performed in all cases). We compared our results according to bleeding-related complications with the data of stereotactic biopsy series from the recent literature. A conclusive histopathological diagnosis was achieved in 150/153 patients (98 %). A re-biopsy had to be undertaken in 2 cases. In 98 biopsies (63 %), no vessel could be detected with the micro-Doppler. In the remainder, a signal of arterial vessels was detected in 22 (14 %) and a signal of venous vessels in 35 cases (23 %). Detection of a vessel in the micro-Doppler led to a change of the biopsy site in each case within the same trajectory. Biopsy-related bleedings were detected in 4 cases (2.6 %). Among these, the only bleeding which occurred without any signs of vessels in the micro-Doppler happened in a case of a melanoma. The overall biopsy-related permanent morbidity was 0.6 % (n = 1). The biopsy-related mortality was 0. Despite the overall high security of SBB, the use of intraoperative micro-Doppler may lead to an additional reduction of the risk for a biopsy-related bleeding without enormous

  2. The U.S.-Mexico Border Infectious Disease Surveillance Project: Establishing Binational Border Surveillance

    Science.gov (United States)

    Waterman, Stephen; Lucas, Carlos Alvarez; Falcon, Veronica Carrion; Morales, Pablo Kuri; Lopez, Luis Anaya; Peter, Chris; Gutiérrez, Alejandro Escobar; Gonzalez, Ernesto Ramirez; Flisser, Ana; Bryan, Ralph; Valle, Enrique Navarro; Rodriguez, Alfonso; Hernandez, Gerardo Alvarez; Rosales, Cecilia; Ortiz, Javier Arias; Landen, Michael; Vilchis, Hugo; Rawlings, Julie; Leal, Francisco Lopez; Ortega, Luis; Flagg, Elaine; Conyer, Roberto Tapia; Cetron, Martin

    2003-01-01

    In 1997, the Centers for Disease Control and Prevention, the Mexican Secretariat of Health, and border health officials began the development of the Border Infectious Disease Surveillance (BIDS) project, a surveillance system for infectious diseases along the U.S.-Mexico border. During a 3-year period, a binational team implemented an active, sentinel surveillance system for hepatitis and febrile exanthems at 13 clinical sites. The network developed surveillance protocols, trained nine surveillance coordinators, established serologic testing at four Mexican border laboratories, and created agreements for data sharing and notification of selected diseases and outbreaks. BIDS facilitated investigations of dengue fever in Texas-Tamaulipas and measles in California–Baja California. BIDS demonstrates that a binational effort with local, state, and federal participation can create a regional surveillance system that crosses an international border. Reducing administrative, infrastructure, and political barriers to cross-border public health collaboration will enhance the effectiveness of disease prevention projects such as BIDS. PMID:12533288

  3. Laser Doppler perfusion monitoring and imaging of blood microcirculation

    Science.gov (United States)

    Nilsson, Gert E.; Wardell, Karin

    1994-07-01

    Laser Doppler perfusion monitoring is a method of assessing tissue perfusion based on measurements performed using Doppler broadening of monochromatic light scattered in moving blood cells. Ever since laser Doppler perfusion monitors became available about 15 years ago they have been used in numerous applications in both clinical and laboratory settings. The high spatial resolution has in practice manifested itself as one of the main limitations of the method. The reason for this is the difficulty in attaining reproducible values at successive measurement sites because most skin tissue possesses a substantial variation in blood flow even at adjacent measurement sites. In order to overcome this difficulty the laser Doppler perfusion imager was developed. In this camera-like device, the laser beam successively scans the tissue and the Doppler components of the backscattered light are detected by a remote photodiode. After a scanning procedure is complete, a color-coded perfusion map showing the spatial variation of skin blood flow is displayed on a monitor. The operating principle and early applications of this emerging technology are addressed in further detail.

  4. Short period ionospheric perturbations from continuous Doppler sounding

    Science.gov (United States)

    Fiser, Jiri; Chum, Jaroslav; Lastovicka, Jan; Buresova, Dalia

    2017-04-01

    Results of recent observations of ionospheric perturbations on short time scales obtained by international network (Czech Republic, Argentina, Taiwan and South Africa) of multipoint continuous Doppler sounders with time resolution about 10 s are presented. Examples of observation and analysis of propagation of gravity waves (GWs), equatorial spread F (ESF), infrasound from earthquake and large convective systems, as well as ionospheric perturbations caused by solar flares will be shown. It is documented that roughly poleward propagation of GWs dominates in the local summer, whereas mainly equatorward propagation is observed in the local winter. The analysis of occurrences and zonal drifts of ESF based on Doppler sounding are consistent with optical and satellite measurements. The observations of co-seismic perturbations by Doppler sounders in the vicinity of ionosondes and seismic sensors proved that the co-seismic perturbations are caused by approximately vertically propagating infrasound waves triggered by vertical motion of the ground surface. Numerical simulations and Doppler measurements confirmed that in the vicinity (up to about 1000 km) from epicenters of strong earthquake, the infrasound propagates in nonlinear regime in the upper atmosphere, which results in the formation of N-shaped pulse. Solar flares are observed both as sudden frequency deviations and amplitude attenuations of Doppler signal.

  5. Detector resolution in positron annihilation Doppler broadening experiments

    Science.gov (United States)

    Heikinheimo, J.; Ala-Heikkilä, J.; Tuomisto, F.

    2017-09-01

    Positron annihilation Doppler broadening spectroscopy characterizes lattice point defects and is sensitive to very small vacancy densities. High-purity germanium detectors are generally used for recording the Doppler broadening spectrum because they provide good energy resolution and stability. However, the energy resolution of a germanium detector is somewhat dependent on the photon absorption geometry in the detector crystal. This change in the energy resolution changes also the Doppler broadening parameters. To observe the dependency of the resolution function and the Doppler broadening parameters, we performed experiments on Si samples in standard sandwich configuration with a Na-22 source. We changed the radiation geometry of the incident gamma photons via altering the distance of the sample-source package from the detector and by adding steel between the source and the detector. We observed the change of the absorption geometry in the germanium detector crystal by doing Monte Carlo simulations. The aim of this study is to help understand and decide what is the best way to compare the Doppler broadening parameters obtained with different measurement setups and even with the same setup when the geometry in the measurements has changed.

  6. Color Doppler US in the acute scrotal disease

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Yoo Mi; Yang, Dal Mo; Kang, Sook Wook; Kim, Hyung Sik; Lee, Young Seok; Kim, Hyeon Hoe [Chung Ang Gil Hospital, Incheon (Korea, Republic of)

    1993-12-15

    To evaluate the utility of Color doppler US in the patients with acute scrotal pain, we retrospectively analyzed 37 patients referred for Color Doppler US of the scrotum. The diagnosis was confirmed by means of appropriate response to antibiotic treatment (31 cases) or surgery (6 cases). Thirty one of 37 patients were diagnosed as inflammatory disease (24 cases of epididymitis, 7 cases of epididymo-orchitis). Twenty three of 24cases of epididymitis had increased epididymal flow, while 6 of 7 cases of epididymo-orchitis had increased epididymal and testicular flow. Five patients were confirmed as testicular torsion, and in all cases nointratesticular blood flow was identified on the symptomatic side. In one case of torsion of appendix testis, epididymis was enlarged and there were increased signals suggesting epididymitis on Color Doppler US, but was confirmed by surgery as torsion of appendix testis. Therefore, the differentiation between torsion and inflammatory disease was possible by using Color Doppler US of the scrotum in 34 of 37 cases in our study. On the basis of our results, we may conclude that Color Doppler US can simultaneously display blood flow and detailed anatomic images, and function as an effective means of evaluating patients with acute scrotal disease

  7. Influence of speckle effect on doppler velocity measurement

    Science.gov (United States)

    Zheng, Zheng; Changming, Zhao; Haiyang, Zhang; Suhui, Yang; Dehua, Zhang; Xingyuan, Zheng; Hongzhi, Yang

    2016-06-01

    In a coherent Lidar system, velocity measurement of a target is achieved by measuring Doppler frequency shift between the echo and local oscillator (LO) signals. The measurement accuracy is proportional to the spectrum width of Doppler signal. Actually, the speckle effect caused by the scattering of laser from a target will broaden the Doppler signal's spectrum and bring uncertainty to the velocity measurement. In this paper, a theoretical model is proposed to predict the broadening of Doppler spectrum with respect to different target's surface and motion parameters. The velocity measurement uncertainty caused by the broadening of spectrum is analyzed. Based on the analysis, we design a coherent Lidar system to measure the velocity of the targets with different surface roughness and transverse velocities. The experimental results are in good agreement with theoretical analysis. It is found that the target's surface roughness and transverse velocity can significantly affect the spectrum width of Doppler signal. With the increase of surface roughness and transverse velocity, the measurement accuracy becomes worse. However, the influence of surface roughness becomes weaker when the spot size of laser beam on the target is smaller.

  8. Response of a Doppler canceling system to plane gravitational waves

    Science.gov (United States)

    Caporali, A.

    1982-01-01

    This paper discusses the interaction of long periodic gravitational waves with a three-link microwave system known as the Doppler canceling system. This system, which was developed for a gravitational red-shift experiment, uses one-way and two-way Doppler information to construct the beat signal of two reference oscillators moving with respect to each other. The geometric-optics approximation is used to derive the frequency shift produced on a light signal propagating in a gravitational-wave space-time. The signature left on the Doppler-cancelled beat by bursts and continuous gravitational waves is analyzed. A comparison is made between the response to gravitational waves of the Doppler canceling system and that of a (NASA) Doppler tracking system which employs two-way, round-trip radio waves. A threefold repetition of the gravitational wave form is found to be a common feature of the response functions of both systems. These two functions otherwise exhibit interesting differences.

  9. Renal Power Doppler Ultrasonographic Evaluation of Children With Acute Pyelonephritis

    Directory of Open Access Journals (Sweden)

    Ali Pahlusi

    2011-10-01

    Full Text Available Urinary tract infections are common in children. The available gold standard method for diagnosis, Tc-99m dimercaptosuccinic acid scan is expensive and exposes patients to considerable amount of radiation. This study was performed to compare and assess the efficacy of Power Doppler Ultrasound versus Tc-99m DMSA scan for diagnosis of acute pyelonephritis. A quasi experimental study was conducted on 34 children with mean age of 2.82.7 years who were hospitalized with their first episode of febrile urinary tract infection. All children were evaluated in the first 3 days of admission by Doppler Ultrasound and Tc-99m DMSA scan. Patients with congenital structural anomalies were excluded. Each kidney was divided into three zones. The comparison between efficacy of Doppler Ultrasound and DMSA scan was carried out based on number of patients and on classified renal units. Based on the number of patients enrolled; the sensitivity, specificity, positive and negative predictive values and accuracy of Doppler Ultrasound were 89%, 53%, 70%, 80% and 74%, respectively but based on the renal units, it was 66%, 81%, 46%, 91% and 79% , respectively. Although Doppler Ultrasound has the potential for identifying acute pyelonephritis in children, but it is still soon to replace DMSA scan.

  10. Radar Scan Strategies for the Patrick Air Force Base Weather Surveillance Radar, Model-74C, Replacement

    Science.gov (United States)

    Short, David

    2008-01-01

    The 45th Weather Squadron (45 WS) is replacing the Weather Surveillance Radar, Model 74C (WSR-74C) at Patrick Air Force Base (PAFB), with a Doppler, dual polarization radar, the Radtec 43/250. A new scan strategy is needed for the Radtec 43/250, to provide high vertical resolution data over the Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS) launch pads, while taking advantage of the new radar's advanced capabilities for detecting severe weather phenomena associated with convection within the 45 WS area of responsibility. The Applied Meteorology Unit (AMU) developed several scan strategies customized for the operational needs of the 45 WS. The AMU also developed a plan for evaluating the scan strategies in the period prior to operational acceptance, currently scheduled for November 2008.

  11. Surveillance studies about "rear-window ethics"%Surveillance studies about"rear-window ethics"

    Institute of Scientific and Technical Information of China (English)

    黄婷婷

    2016-01-01

    It can be said that people now live in a surveillance society. Some forms of surveillance have always existed as people watch over each other for mutual care, for moral caution and to discover information under the table. Alfred Hitchcock's Rear Window is a typical fi lm for surveillance studies.What is happening on the screen is merely a projection of our own anxieties, our own existence, and our self-ambiguity as portrayed by the characters in this wonderful film.

  12. Selection functions in doppler planet searches

    Science.gov (United States)

    O'Toole, S. J.; Tinney, C. G.; Jones, H. R. A.; Butler, R. P.; Marcy, G. W.; Carter, B.; Bailey, J.

    2009-01-01

    We present a preliminary analysis of the sensitivity of Anglo-Australian Planet Search data to the orbital parameters of extrasolar planets. To do so, we have developed new tools for the automatic analysis of large-scale simulations of Doppler velocity planet search data. One of these tools is the two-dimensional Keplerian Lomb-Scargle (LS) periodogram that enables the straightforward detection of exoplanets with high eccentricities (something the standard LS periodogram routinely fails to do). We used this technique to redetermine the orbital parameters of HD20782b, with one of the highest known exoplanet eccentricities (e = 0.97 +/- 0.01). We also derive a set of detection criteria that do not depend on the distribution functions of fitted Keplerian orbital parameters (which we show are non-Gaussian with pronounced, extended wings). Using these tools, we examine the selection functions in orbital period, eccentricity and planet mass of Anglo-Australian Planet Search data for three planets with large-scale Monte Carlo like simulations. We find that the detectability of exoplanets declines at high eccentricities. However, we also find that exoplanet detectability is a strong function of epoch-to-epoch data quality, number of observations and period sampling. This strongly suggests that simple parametrizations of the detectability of exoplanets based on `whole-of-survey' metrics may not be accurate. We have derived empirical relationships between the uncertainty estimates for orbital parameters that are derived from least-squares Keplerian fits to our simulations and the true 99 per cent limits for the errors in those parameters, which are larger than equivalent Gaussian limits by the factors of 5-10. We quantify the rate at which false positives are made by our detection criteria, and find that they do not significantly affect our final conclusions. And finally, we find that there is a bias against measuring near-zero eccentricities, which becomes more significant

  13. Musculoskeletal colour/power Doppler in sports medicine: image parameters, artefacts, image interpretation and therapy

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, Mikael; Kønig, Merete Juhl;

    2010-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some...... guidelines and recommendations are based on personal experience since no evidence in literature exists. The basic technical background of Doppler ultrasound and typical artefacts will be discussed, in order to understand and interpret the Doppler result. Recommendations for the Doppler settings are given...... in relevant sections. Ultrasound guided treatments where the Doppler result is used as a guide are mentioned and discussed....

  14. Crypto and empire: the contradictions of counter-surveillance advocacy

    NARCIS (Netherlands)

    Gürses, S.; Kundnani, A.; Van Hoboken, J.

    2016-01-01

    Since Edward Snowden’s revelations of US and UK surveillance programs, privacy advocates, progressive security engineers, and policy makers have been seeking to win majority support for countering surveillance. The problem is framed as the replacement of targeted surveillance with mass surveillance

  15. 48 CFR 37.604 - Quality assurance surveillance plans.

    Science.gov (United States)

    2010-10-01

    ... assurance surveillance plans. Requirements for quality assurance and quality assurance surveillance plans are in Subpart 46.4. The Government may either prepare the quality assurance surveillance plan or require the offerors to submit a proposed quality assurance surveillance plan for the Government's...

  16. Surveillance and Datenschutz in Virtual Environments

    Science.gov (United States)

    Cikic, Sabine; Lehmann-Grube, Fritz; Sablatnig, Jan

    Virtual environments are becoming more and more accepted, and part of the everyday online experience for many users. This offers new potential for both surveillance and data mining. Some of the techniques used are discussed in this paper.

  17. CDC Behavioral Risk Factor Surveillance System (BRFSS)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Behavioral Risk Factor Surveillance System (BRFSS) is a state-based system of health surveys that collects information on health risk behaviors, preventive...

  18. Donning and doffing PPE for HPAI surveillance

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — Instructions describing the proper donning and doffing personal protective equipment (PPE) for highly pathogenic avian influenza (HPAI) surveillance. This protocol...

  19. Youth Risk Behavior Surveillance System (YRBSS)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Youth Risk Behavior Surveillance System (YRBSS) monitors 6 types of health-risk behaviors that contribute to the leading causes of death and disability among...

  20. Surveillance and Monitoring of Dialysis Access

    Directory of Open Access Journals (Sweden)

    Lalathaksha Kumbar

    2012-01-01

    Full Text Available Vascular access is the lifeline of a hemodialysis patient. Currently arteriovenous fistula and graft are considered the permanent options for vascular access. Monitoring and surveillance of vascular access are an integral part of the care of hemodialysis patient. Although different techniques and methods are available for identifying access dysfunction, the scientific evidence for the optimal methodology is lacking. A small number of randomized controlled trials have been performed evaluating different surveillance techniques. We performed a study of the recent literature published in the PUBMED, to review the scientific evidence on different methodologies currently being used for surveillance and monitoring and their impact on the care of the dialysis access. The limited randomized studies especially involving fistulae and small sample size of the published studies with conflicting results highlight the need for a larger multicentered randomized study with hard clinical end points to evaluate the optimal surveillance strategy for both fistula and graft.

  1. Hanford Site Environmental Surveillance Master Sampling Schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2000-01-27

    This document contains the CY2000 schedules for the routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes sampling locations, sample types, and analyses to be performed.

  2. Future Airportal Surveillance and Prediction Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Recent advances in airport surface surveillance and other sensor, automation, and data sharing technologies now allow the consideration of a significant change in...

  3. Moving object detection for video surveillance

    National Research Council Canada - National Science Library

    Kalirajan, K; Sudha, M

    2015-01-01

    .... In this paper, a novel approach of object detection for video surveillance is presented. The proposed algorithm consists of various steps including video compression, object detection, and object localization...

  4. Disease Surveillance at Rocky Mountain Arsenal NWR

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — Deer populations have been reduced under the new Habitat Management Plan (HMP). Surveillance of chronic wasting disease (CWD) and other common ungulate diseases...

  5. Ecocardiografia modo Doppler pulsado em gatos clinicamente sadios Pulsed wave Doppler echocardiography in clinically healthy cats

    Directory of Open Access Journals (Sweden)

    R.O. Carvalho

    2006-06-01

    Full Text Available Estudou-se o fluxo sangüíneo através das quatro valvas cardíacas em 30 gatos clinicamente sadios, com idade entre um e cinco anos e peso médio de 4,08kg, por meio da ecocardiografia modo Doppler pulsado. Foram medidas a velocidade máxima e a velocidade média dos fluxos, e realizou-se uma análise qualitativa dos seus perfis. Os animais foram sedados pela combinação de quetamina (12mg/kg e acepromazina (0,04mg/kg, aplicados por via intramuscular. Observou-se correlação positiva entre os parâmetros avaliados e a freqüência cardíaca, com exceção daqueles medidos no fluxo da valva aórtica. Não se observou correlação entre velocidades máxima e média e freqüência cardíaca e entre aquelas e peso corporal, e não houve diferença entre sexos.Pulsed wave Doppler echocardiography was used to study blood flow across the cardiac valves in 30 five-year-old cats (average body weight = 4.08kg. Animals were sedated using a combination of ketamin (12mg/kg, IM and acepromazin (0.04mg/kg, IM. Peak and mean velocities were determined, and blood flow patterns were recorded at the four cardiac valves. All variables, except those characterizing aortic valve flow, were positively correlated with heart rate. Blood flow variables were not correlated, however, with body weight; and there were no differences between males and females.

  6. Malaria Surveillance - United States, 2014.

    Science.gov (United States)

    Mace, Kimberly E; Arguin, Paul M

    2017-05-26

    Malaria in humans is caused by intraerythrocytic protozoa of the genus Plasmodium. These parasites are transmitted by the bite of an infective female Anopheles mosquito. The majority of malaria infections in the United States occur among persons who have traveled to regions with ongoing malaria transmission. However, malaria is occasionally acquired by persons who have not traveled out of the country through exposure to infected blood products, congenital transmission, laboratory exposure, or local mosquitoborne transmission. Malaria surveillance in the United States is conducted to identify episodes of local transmission and to guide prevention recommendations for travelers. This report summarizes cases in persons with onset of illness in 2014 and trends during previous years. Malaria cases diagnosed by blood film, polymerase chain reaction, or rapid diagnostic tests are reported to local and state health departments by health care providers or laboratory staff. Case investigations are conducted by local and state health departments, and reports are transmitted to CDC through the National Malaria Surveillance System, National Notifiable Diseases Surveillance System, or direct CDC consultations. CDC conducts antimalarial drug resistance marker testing on blood samples submitted by health care providers or local or state health departments. Data from these reporting systems serve as the basis for this report. CDC received reports of 1,724 confirmed malaria cases, including one congenital case and two cryptic cases, with onset of symptoms in 2014 among persons in the United States. The number of confirmed cases in 2014 is consistent with the number of confirmed cases reported in 2013 (n = 1,741; this number has been updated from a previous publication to account for delayed reporting for persons with symptom onset occurring in late 2013). Plasmodium falciparum, P. vivax, P. ovale, and P. malariae were identified in 66.1%, 13.3%, 5.2%, and 2.7% of cases, respectively

  7. Tank Farm Operations Surveillance Automation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    MARQUEZ, D.L.

    2000-12-21

    The Nuclear Operations Project Services identified the need to improve manual tank farm surveillance data collection, review, distribution and storage practices often referred to as Operator Rounds. This document provides the analysis in terms of feasibility to improve the manual data collection methods by using handheld computer units, barcode technology, a database for storage and acquisitions, associated software, and operational procedures to increase the efficiency of Operator Rounds associated with surveillance activities.

  8. Enhanced surveillance program FY1998 accomplishments

    Energy Technology Data Exchange (ETDEWEB)

    Kass, J

    1998-10-01

    This report highlights the accomplishments of the Enhanced Surveillance Program (ESP), the highest-priority research and development effort in stockpile management today. This is volume one of eleven, the unclassified summary of selected program highlights. These highlights fall into the following focus areas: pits, high explosives, organics, dynamics, diagnostics, systems, secondaries, materials-aging models, non-nuclear components, and routine surveillance testing system upgrades. Principal investigators from around the DOE complex contributed to this report.

  9. Workplace surveillance, privacy protection, and efficiency wages

    OpenAIRE

    Schmitz, Patrick W.

    2005-01-01

    Consider an employer who wants her employee to work hard. As is well known from the efficiency wage literature, the employer must pay the (wealth-constrained) employee a positive rent to provide incentives for exerting unobservable effort. Alternatively, the employer could make effort observable by costly workplace surveillance. It is argued that a privacy protection law preventing surveillance may increase the total surplus. While such a law reduces the employer?s profit, this loss can be ov...

  10. Microbiological Food Safety Surveillance in China

    OpenAIRE

    Xiaoyan Pei; Ning Li; Yunchang Guo; Xiumei Liu; Lin Yan; Ying Li; Shuran Yang; Jing Hu; Jianghui Zhu; Dajin Yang

    2015-01-01

    Microbiological food safety surveillance is a system that collects data regarding food contamination by foodborne pathogens, parasites, viruses, and other harmful microbiological factors. It helps to understand the spectrum of food safety, timely detect food safety hazards, and provide relevant data for food safety supervision, risk assessment, and standards-setting. The study discusses the microbiological surveillance of food safety in China, and introduces the policies and history of the na...

  11. Hanford Site Environmental Surveillance Master Sampling Schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2002-01-16

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs. The document contains the CY 2002 schedules for the routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project.

  12. Customer Surveillance: Consumer Attitudes and Management Strategies

    OpenAIRE

    Plangger, Kirk Anton

    2015-01-01

    Due to technological advances, customer surveillance (i.e., the collection, capture, use, or storage of customers’ personal data) is becoming less expensive and more covert. Brands use these personal data that contain needs, preferences, characteristics, behavior, attitudes, or other customer attributes (i.e., market intelligence) to develop more competitive products and services. Customer surveillance also can put stress on customer relationships with brands, thus brands must conduct custome...

  13. Non-Gaussianity and CMB aberration and Doppler

    CERN Document Server

    Catena, Riccardo; Notari, Alessio; Renzi, Alessandro

    2013-01-01

    The peculiar motion of an observer with respect to the CMB rest frame induces a deflection in the arrival direction of the observed photons (also known as CMB aberration) and a Doppler shift in the measured photon frequencies. As a consequence, aberration and Doppler effects induce non trivial correlations between the harmonic coefficients of the observed CMB temperature maps. In this paper we investigate whether these correlations generate a bias on Non-Gaussianity estimators $f_{NL}$. We perform this analysis simulating a large number of temperature maps with Planck-like resolution (lmax $= 2000$) as different realizations of the same cosmological fiducial model (WMAP7yr). We then add to these maps aberration and Doppler effects employing a modified version of the HEALPix code. We finally evaluate a generalization of the Komatsu, Spergel and Wandelt Non-Gaussianity estimator for all the simulated maps, both when peculiar velocity effects have been considered and when these phenomena have been neglected. Usi...

  14. Doppler Spectrum from Moving Scatterers in a Random Environment

    DEFF Research Database (Denmark)

    Andersen, Jørgen Bach; Nielsen, Jesper Ødum; Pedersen, Gert Frølund

    2009-01-01

    as well as sharply peaked distributions are considered in the theory. The Doppler spectra are in all cases sharply peaked at zero frequency due to forward scattering, but the actually measured distribution depends on the degree and type of activity in the environment, as well as the spectrum estimation......A random non-line-of-sight environment with stationary transmitter and receiver is considered. In such an environment movement of a scatterer will lead to perturbations of the otherwise static channel with a resulting Doppler spectrum. This is quite a general situation in outdoor environments...... with moving traffic or indoor situations with moving people. Here we study the latter situation in detail with experimental results from a large office environment. A general theory of Doppler spectra is developed. The impact of a scatterer depends on the angular distribution of scattered energy, and uniform...

  15. One way Doppler Extractor. Volume 2: Digital VCO technique

    Science.gov (United States)

    Nossen, E. J.; Starner, E. R.

    1974-01-01

    A feasibility analysis and trade-offs for a one-way Doppler extractor using digital VCO techniques is presented. The method of Doppler measurement involves the use of a digital phase lock loop; once this loop is locked to the incoming signal, the precise frequency and hence the Doppler component can be determined directly from the contents of the digital control register. The only serious error source is due to internally generated noise. Techniques are presented for minimizing this error source and achieving an accuracy of 0.01 Hz in a one second averaging period. A number of digitally controlled oscillators were analyzed from a performance and complexity point of view. The most promising technique uses an arithmetic synthesizer as a digital waveform generator.

  16. Micro-range micro-doppler for dismount classification

    Science.gov (United States)

    Tahmoush, Dave

    2013-05-01

    This paper presents a processing technique that can be used to detect and classify pedestrians group based on the micro- Doppler signature gathered with a millimeter wave radar. The evaluation of the number of pedestrians moving in a group can be a difficult task using a traditional micro-Doppler spectrogram because of a tendency for people to partially synchronize their steps when walking together. The new approach, based on multi-range variation as well as the micro-Doppler variations, provides promising results. The range-spectrogram processing technique was developed and tested using a database composed of hundreds of pedestrian and vehicle signatures gathered in an urban test site over a two year period in a variety of weather conditions. We associate image detections with radar detections through motion extracted from both radar and imagery. We also explain how radar and video together can produce an inexpensive alternative to 3-D imaging.

  17. Automatic human micro-Doppler signature separation by Hough transform

    Science.gov (United States)

    Zhang, Jun; Jin, Tian; Qiu, Lei; Zhou, Zhimin

    2015-12-01

    The micro-Doppler signature is one of the most prominent information for target classification and identification. As Hough transform (HT) is an efficient tool for detecting weak straight target traces in the image, an HT based algorithm is proposed for micro-Doppler signature separation of multiple persons. Few seconds data is processed at one time to ensure human motion traces approximate to straight lines in the radar slow time-range image. Taking HT to the slow time-range image, each human's motion trace can be recovered through recursively searching the peaks in HT space. Applying time-frequency transform to the range cells around each recovered line, the human micro-Doppler signature can be achieved and separated. Experimental results are given to illustrate the validity of the proposed algorithm.

  18. Holographic laser Doppler imaging of microvascular blood flow

    CERN Document Server

    Magnain, C; Boucneau, T; Simonutti, M; Ferezou, I; Rancillac, A; Vitalis, T; Sahel, J A; Paques, M; Atlan, M

    2014-01-01

    We report on local superficial blood flow monitoring in biological tissue from laser Doppler holographic imaging. In time averaging recording conditions, holography acts as a narrowband bandpass filter, which, combined with a frequency shifted reference beam, permits frequency selective imaging in the radiofrequency range. These Doppler images are acquired with an off axis Mach Zehnder interferometer. Microvascular hemodynamic components mapping is performed in the cerebral cortex of the mouse and the eye fundus of the rat with near-infrared laser light without any exogenous marker. These measures are made from a basic inverse method analysis of local first order optical fluctuation spectra at low radiofrequencies, from 0 Hz to 100 kHz. Local quadratic velocity is derived from Doppler broadenings induced by fluid flows, with elementary diffusing wave spectroscopy formalism in backscattering configuration. We demonstrate quadratic mean velocity assessment in the 0.1 to 10 millimeters per second range in vitro ...

  19. Improved technique for blood flow velocity measurement using Doppler effect

    Science.gov (United States)

    Valadares Oliveira, Eduardo J.; Nantes Button, Vera L. d. S.; Maia, Joaquim M.; Costa, Eduardo T.

    2002-04-01

    The Doppler velocimeter developed allows to determine the angle between the ultrasonic beam and the velocity vector of the flow, and to calculate the precise blood flow in a vessel. Four piezoelectric transducers constitute the Doppler velocimeter. Three of these transducers are positioned to form an equilateral triangle (base of a pyramid). When these transducers move simultaneously, backward or forward from the initial position, the emitted ultrasonic beams focalize on a position (peak of the pyramid) closer or farther from the transducers faces, according to the depth of the vessel where we intend to measure de flow. The angle between the transducers allows adjusting the height of this pyramid and the position of the focus (where the three beams meet). A forth transducer is used to determine the diameter of the vessel and monitor the position of the Doppler velocimeter relative to the vessel. Simulation results showed that with this technique is possible to accomplish precise measurement of blood flow.

  20. Curvelet Transform-Based Denoising Method for Doppler Frequency Extraction

    Institute of Scientific and Technical Information of China (English)

    HOU Shu-juan; WU Si-liang

    2007-01-01

    A novel image denoising method based on curvelet transform is proposed in order to improve the performance of Doppler frequency extraction in low signal-noise-ratio (SNR) environment. The echo can be represented as a gray image with spectral intensity as its gray values by time-frequency transform. And the curvelet coefficients of the image are computed. Then an adaptive soft-threshold scheme based on dual-median operation is implemented in curvelet domain. After that, the image is reconstructed by inverse curvelet transform and the Doppler curve is extracted by a curve detection scheme. Experimental results show the proposed method can improve the detection of Doppler frequency in low SNR environment.

  1. Theoretical analysis and experimental verification on optical rotational Doppler effect

    CERN Document Server

    Zhou, Hailong; Dong, Jianji; Zhang, Pei; Zhang, Xinliang

    2016-01-01

    We present a theoretical model to sufficiently investigate the optical rotational Doppler effect based on modal expansion method. We find that the frequency shift content is only determined by the surface of spinning object and the reduced Doppler shift is linear to the difference of mode index between input and output orbital angular momentum (OAM) light, and linear to the rotating speed of spinning object as well. An experiment is carried out to verify the theoretical model. We explicitly suggest that the spatial spiral phase distribution of spinning object determines the frequency content. The theoretical model makes us better understand the physical processes of rotational Doppler effect, and thus has many related application fields, such as detection of rotating bodies, imaging of surface and measurement of OAM light.

  2. Doppler-like effect and doubtful expansion of universe

    CERN Document Server

    Szaraniec, E

    2003-01-01

    The distance contraction, as observed in electrical soundings over horizontally stratified earth (static system), is identified as a counterpart of Doppler shift in dynamical systems. Identification of Doppler-like effect in a stock-still systems makes it possible to give an al-ternative answer to the question about an effective cause of the Doppler shift, which sounds: the inhomogeneities. This answer opens different static as well as kinematic possibilities, which challenge established theories of expanding universe and energizing big bang.The energy propagating in stratified universe of layers exhibits a shift which could be at-tributed not only to the expansion (Hubble's theory) but alternatively to fluctuations in material properties (inhomogeneities).

  3. It's all in the past: Deconstructing the temporal Doppler effect.

    Science.gov (United States)

    Aksentijevic, Aleksandar; Treider, John Melvin Gudnyson

    2016-10-01

    A recent study reported an asymmetry between subjective estimates of future and past distances with passive estimation and virtual movement. The temporal Doppler effect refers to the contraction of future distance judgments relative to past ones. We aimed to replicate the effect using real and imagined motion in both directions as well as different temporal perspectives. To avoid the problem of subjective anchoring, we compared real- and imagined-, ego- and time-moving conditions to a control group. Generally, Doppler-like distortion was only observed in conditions in which the distance between the participant and a frontal target increased. No effects of temporal perspective were observed. The "past-directed temporal Doppler effect" presents a challenge for the current theories of temporal cognition by demonstrating absence of psychological movement into the future. The effect could open new avenues in memory research and serve as a starting point in a systematic examination of how the humans construct future.

  4. Rotational Doppler Effect: A Probe for Molecular Orbitals Anisotropy.

    Science.gov (United States)

    Miao, Quan; Travnikova, Oksana; Gel'mukhanov, Faris; Kimberg, Victor; Sun, Yu-Ping; Thomas, T Darrah; Nicolas, Christophe; Patanen, Minna; Miron, Catalin

    2015-05-01

    The vibrationally resolved X-ray photoelectron spectra of X2Σg+(3σg−1) and B2Σu+(2σu−1) states of N2+ were recorded for different photon energies and orientations of the polarization vector. Clear dependencies of the spectral line widths on the X-ray polarization as well as on the symmetry of the final electronic states are observed. Contrary to the translational Doppler, the rotational Doppler broadening is sensitive to the photoelectron emission anisotropy. On the basis of theoretical modeling, we suggest that the different rotational Doppler broadenings observed for gerade and ungerade final states result from a Young's double-slit interference phenomenon.

  5. Theoretical analysis and experimental verification on optical rotational Doppler effect

    Science.gov (United States)

    Zhou, Hailong; Fu, Dongzhi; Dong, Jianji; Zhang, Pei; Zhang, Xinliang

    2016-05-01

    We present a theoretical model to sufficiently investigate the optical rotational Doppler effect based on modal expansion method. We find that the frequency shift content is only determined by the surface of spinning object and the reduced Doppler shift is linear to the difference of mode index between input and output orbital angular momentum (OAM) light, and linear to the rotating speed of spinning object as well. An experiment is carried out to verify the theoretical model. We explicitly suggest that the spatial spiral phase distribution of spinning object determines the frequency content. The theoretical model makes us better understand the physical processes of rotational Doppler effect, and thus has many related application fields, such as detection of rotating bodies, imaging of surface and measurement of OAM light.

  6. The Doppler paradigm and the APEX-EPOS-ORANGE quandary

    CERN Document Server

    Griffin, J J

    1996-01-01

    The experimental detection of the sharp lines of the \\ee Puzzle is viewed as a struggle against Doppler broadening. Gedanken experiments which are realistic in zeroth order of detail are analyzed to show that the ORANGE and EPOS/I geometries select narrower slices of a Doppler broadened line than spherically inclusive (APEX and EPOS/II --like) apparati. Roughly speaking, the latter require event-by-event Doppler reconstruction simply to regain an even footing with the former. This suggests that APEX' or EPOS/II's coincident pair distributions must be statistically superior to those of EPOS/I or ORANGE in order to support a comparable inference about sharp structure. Under present circumstances, independent alternative data is invaluable. Therefore, a corroboration of Sakai's 330.1 keV (< 3 keV wide) electron line in few MeV e^+ or e^- bombardments of U and Th targets could prove crucial.

  7. Liberal luxury: Decentering Snowden, surveillance and privilege

    Directory of Open Access Journals (Sweden)

    Piro Rexhepi

    2016-11-01

    Full Text Available This paper reflects on the continued potency of veillance theories to traverse beyond the taxonomies of surveillance inside liberal democracies. It provides a commentary on the ability of sousveillance to destabilise and disrupt suer/violence by shifting its focus from the centre to the periphery, where Big Data surveillance is tantamount to sur/violence. In these peripheral political spaces, surveillance is not framed by concerns over privacy, democracy and civil society; rather, it is a matter of life and death, a technique of both biopolitical and thanatopolitical power. I argue that the universalist, and universalizing, debates over surveillance cannot be mapped through the anxieties of privileged middle classes as they would neither transcend nor make possible alternative ways of tackling the intersection of surveillance and violence so long as they are couched in the liberal concerns for democracy. I call this phenomenon “liberal luxury,” whereby debates over surveillance have over-emphasised liberal proclivities at the expense of disengaging those peripheral populations most severely affected by sur/violence.

  8. Doppler changes as the earliest parameter in fetal surveillance to detect fetal compromise in intrauterine growth-restricted fetuses: Erratum

    Directory of Open Access Journals (Sweden)

    Editorial

    2017-01-01

    Full Text Available In the article that appeared on pages 69-73 of the January-February 2016 issue of the Serbian Archives of Medicine (“Srpski arhiv za celokupno lekarstvo”; Srp Arh Celok Lek. 2016 Jan-Feb; 144(1-2:69-73; doi: 10.2298/SARH1602069B, there is an inaccuracy regarding the stated authors of the article (Saloni Bansal, Deepika Deka, Vatsla Dhadwal, Rajiv Mahendru; the authors should be in fact listed in the following manner: Saloni Bansal, Dipika Deka, Vatsla Dadhwal, Neeta Singh, Smriti Hari. The authors, as well as the publisher, regret this error. Link to the corrected article 10.2298/SARH1602069B

  9. The US color Doppler in acute renal failure.

    Science.gov (United States)

    Nori, G; Granata, A; Leonardi, G; Sicurezza, E; Spata, C

    2004-12-01

    Imaging techniques, especially ultrasonography and Doppler, can give an effective assistance in the differential diagnosis of acute renal failure (ARF). An resistance Index (RI) value >0.75 is reported as optimal in attempting differential diagnosis between acute tubular necrosis (ANT) and prerenal ARF. In hepatorenal syndrome (HRS) RIs is very increased. In some renal vasculitis, as nodose panarteritis (PN), hemolytic-uremic syndrome (HUS), thrombotic thrombocytopenic purpura (TTP), parenchymal perfusion is reduced and RI increased. In lupus nephritis the RI values are correlated with creatinine level and normal RI are considered as a good prognostic tool. In acute primitive or secondary glomerulonephritis (GN), RI value is normal, with diffuse parenchymal hypervascularization. In acute crescentic and proliferative GN and tubulo-interstitial disease, color Doppler (CD) and power Doppler (PD) reveal a decreased renal parenchymal perfusion, which correlates with increased RI values. In acute thrombosis of renal artery, US color Doppler (DUS) reveals either an absence of Doppler signal or a tardus-parvus pulse distal to the vascular obstruction. In this situation it is possible to visualize hyperthropic perforating vessels that redirect their flow from the capsular plexus to the renal parenchyma. In acute thrombosis of the renal vein Doppler analysis of parenchymal vessels reveals remarkable RI values, sometimes with reversed diastolic flow. In postrenal ARF an adjunct to the differentiation between obstruction and non obstructive dilatation can be found through RIs. Diagnostic criteria of obstruction as reported by literature are: RI>0.70 in the obstructed kidney and, mostly, a difference in RI between the 2 kidneys >0.06-0.1.

  10. Reducing Antenna Mechanical Noise in Precision Doppler Tracking

    Science.gov (United States)

    Armstrong, J. W.; Estabrook, F. B.; Asmar, S. W.; Iess, L.; Tortora, P.

    2006-05-01

    Precision Doppler tracking of deep-space probes is central to spacecraft navigation and many radio science investigations. The most sensitive Doppler observations to date have been taken using the NASA/JPL Deep Space Network (DSN) antenna DSS 25, a 34-m-diameter beam-waveguide station especially instrumented with simultaneous X-band (approximately 8.4-GHz) and Ka-band (approximately 32-GHz) links and tropospheric scintillation calibration equipment, tracking the Cassini spacecraft. These Cassini observations achieved Doppler fractional frequency stability (Doppler frequency fluctuation divided by center frequency, Delta f / f_o ) of approximately 3 x 10^-15 at tau = 1000 s integration. In those very-high-sensitivity tracks, the leading disturbance was antenna mechanical noise: time-dependent unmodeled physical motion of the ground antenna's phase center caused by antenna sag as the elevation angle changed, unmodeled subreflector motion, wind loading, bulk motion of the antenna as it rolled over irregularities in the supporting azimuth ring, differential thermal expansion of the structure, etc. This noise has seemed irreducible at reasonable cost, since it is unclear how to build a practical, large, moving, steel structure having mechanical stability significantly better than that of current tracking stations. Here we show how the mechanical noise of a large tracking antenna can effectively be removed when two-way Doppler tracking data from an existing DSN antenna are suitably combined with simultaneous tracking data using an ancillary (smaller and stiffer) antenna. Using our method, the mechanical noise in the final Doppler observable can be reduced, substantially, to that of the stiffer antenna.

  11. UltraFast Doppler ultrasonography for hepatic vessels of liver recipients: preliminary experiences

    Energy Technology Data Exchange (ETDEWEB)

    Hur, Bo Yun; Lee, Jae Young; Chu, A Jung; Kim, Se Hyung; Han, Joon Koo; Choi, Byung Ihn [Seoul National University Hospital, Seoul (Korea, Republic of)

    2015-01-15

    The purpose of this study was to investigate the value of UltraFast Doppler ultrasonography (US) for evaluating hepatic vessels in liver recipients. Thirty-nine liver Doppler US sessions were conducted in 20 liver recipients. Each session consisted of UltraFast and conventional liver Doppler US in a random order. We compared the velocities and phasicities of the hepatic vessels, duration of each Doppler study, occurrence of technical failures, and differences in clinical decisions. The velocities and resistive index values of hepatic vessels showed a strong positive correlation between the two Doppler studies (mean R=0.806; range, 0.710 to 0.924). The phasicities of the hepatic vessels were the same in both Doppler US exams. With respect to the duration of the Doppler US exam, there was no significant difference between the UltraFast (251±99 seconds) and conventional (231±117 seconds) Doppler studies (P=0.306). In five poor breath-holders, in whom the duration of conventional Doppler US was longer, UltraFast Doppler US (272±157 seconds) required a shorter time than conventional Doppler US (381±133 seconds; P=0.005). There was no difference between the two techniques with respect to technical failures and clinical decisions. UltraFast Doppler US is clinically equivalent to conventional Doppler US with advantages for poor breath-holders during the post-liver transplantation work-up.

  12. A review of Doppler ultrasound quality assurance protocols and test devices.

    Science.gov (United States)

    Browne, Jacinta E

    2014-11-01

    In this paper, an overview of Doppler ultrasound quality assurance (QA) testing will be presented in three sections. The first section will review the different Doppler ultrasound parameters recommended by professional bodies for use in QA protocols. The second section will include an evaluation and critique of the main test devices used to assess Doppler performance, while the final section of this paper will discuss which of the wide range of test devices have been found to be most suitable for inclusion in Doppler QA programmes. Pulsed Wave Spectral Doppler, Colour Doppler Imaging QA test protocols have been recommended over the years by various professional bodies, including the UK's Institute of Physics and Engineering in Medicine (IPEM), the American Institute for Ultrasound in Medicine (AIUM), and the International Electrotechnical Commission (IEC). However, despite the existence of such recommended test protocols, very few commercial or research test devices exist which can measure the full range of both PW Doppler ultrasound and colour Doppler imaging performance parameters, particularly quality control measurements such as: (i) Doppler sensitivity (ii) colour Doppler spatial resolution (iii) colour Doppler temporal resolution (iv) colour Doppler velocity resolution (v) clutter filter performance and (vi) tissue movement artefact suppression. In this review, the merits of the various commercial and research test devices will be considered and a summary of results obtained from published studies which have made use of some of these Doppler test devices, such as the flow, string, rotating and belt phantom, will be presented.

  13. Miniature Laser Doppler Velocimeter for Measuring Wall Shear

    Science.gov (United States)

    Gharib, Morteza; Modarress, Darius; Forouhar, Siamak; Fourguette, Dominique; Taugwalder, Federic; Wilson, Daniel

    2005-01-01

    A miniature optoelectronic instrument has been invented as a nonintrusive means of measuring a velocity gradient proportional to a shear stress in a flow near a wall. The instrument, which can be mounted flush with the wall, is a variant of a basic laser Doppler velocimeter. The laser Doppler probe volume can be located close enough to the wall (as little as 100 micron from the surface) to lie within the viscosity-dominated sublayer of a turbulent boundary layer. The instrument includes a diode laser, the output of which is shaped by a diffractive optical element (DOE) into two beams that have elliptical cross sections with very high aspect ratios.

  14. Optical Doppler tomography based on a field programmable gate array

    DEFF Research Database (Denmark)

    Larsen, Henning Engelbrecht; Nilsson, Ronnie Thorup; Thrane, Lars

    2008-01-01

    We report the design of and results obtained by using a field programmable gate array (FPGA) to digitally process optical Doppler tomography signals. The processor fits into the analog signal path in an existing optical coherence tomography setup. We demonstrate both Doppler frequency and envelope...... extraction using the Hilbert transform, all in a single FPGA. An FPGA implementation has certain advantages over general purpose digital signal processor (DSP) due to the fact that the processing elements operate in parallel as opposed to the DSP. which is primarily a sequential processor....

  15. Experimental Verification of Doppler Effect with the Refraction Method

    Institute of Scientific and Technical Information of China (English)

    Lie FENG; Jia-bi CHEN; Jing-bin HU; Song-lin ZHUANG

    2010-01-01

    The traditional methad of measuring Dopplr Effect is either reflection or dispersion.This article clarifies that it can also verify the Doppler Effect with the refraction method.We have designed the experimental system with the method of optical heterodyne,using the refraction light beam from a prism,and made the experiment.The experimental results are in accordance with the theoreticai calculation.It is very useful in some particular case,such as in Negative-Index Materials(NIM),to verify the Doppler Effect with this method.

  16. Multigroup Free-atom Doppler-broadening Approximation. Theory

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Mark Girard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-06

    Multigroup cross sections at a one target temperature can be Doppler-broadened to multigroup cross sections at a higher target temperature by matrix multiplication if the group structure suf- ficiently resolves the original temperature continuous energy cross section. Matrix elements are the higher temperature group weighted averages of the integral over the lower temperature group boundaries of the free-atom Doppler-broadening kernel. The results match theory for constant and 1/v multigroup cross sections at 618 lanl group structure resolution.

  17. Single pass Doppler positioning for Search and Rescue satellite missions

    Science.gov (United States)

    Schmid, P. E.; Vonbun, F. O.; Lynn, J. J.

    1976-01-01

    This paper describes the implementation of beacon location experiments involving the NASA Nimbus-6 and the Amateur Satellite Corporation (AMSAT) Oscar-6 and Oscar-7 spacecraft. The purpose of these experiments is to demonstrate the feasibility of determining the geographical location of a low power VHF 'distress beacon' via satellite. Doppler data collected during satellite passes is reduced in a mini-computer by means of a simple algorithm resulting in the simultaneous recovery of the unknown receiver coordinates and the unknown Doppler bias frequency. Results indicate point positioning to within a few kilometers - which is within the required accuracies for the positioning of downed aircraft for Search/Rescue missions.

  18. Wide-band coherent receiver development for enhanced surveillance

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, M.L.; Richards, R.K.; Hutchinson, D.P.

    1998-03-01

    Oak Ridge National Laboratory (ORNL) has been developing advanced coherent IR heterodyne receivers for plasma diagnostics in fusion reactors for over 20 years. Recent progress in wide band IR detectors and high speed electronics has significantly enhanced the measurement capabilities of coherent receivers. In addition, developments in new HgCdTe and quantum well IR photodetector (QWIP) focal plane arrays are providing the possibility of both active and passive coherent imaging. In this paper the authors discuss the implications of these new enabling technologies to the IR remote sensing community for enhanced surveillance. Coherent receivers, as opposed to direct or thermal detection, provide multiple dimensions of information about a scene or target in a single detector system. Combinations of range, velocity, temperature, and chemical species information are all available from a coherent heterodyne receiver. They present laboratory data showing measured noise equivalent power (NEP) of new QWIP detectors with heterodyne bandwidths greater than 7 GHz. For absorption measurements, a wide band coherent receiver provides the capability of looking between CO{sub 2} lines at off-resonance peaks and thus the measurement of lines normally inaccessible with conventional heterodyne or direct detection systems. Also described are differential absorption lidar (DIAL) and Doppler laboratory measurements using an 8 x 8 HgCdTe focal plane array demonstrating the snapshot capability of coherent receiver detector arrays for enhanced chemical plume and moving hardbody capture. Finally they discuss a variety of coherent receiver configurations that can suppress (or enhance) sensitivity of present active remote sensing systems to speckle, glint, and other measurement anomalies.

  19. Acoustic doppler methods for remote measurements of ocean flows - a review

    Digital Repository Service at National Institute of Oceanography (India)

    Joseph, A.

    The evolution of acoustic doppler methods for remote measurements of ocean flows has been briefly reviewed in historical perspective. Both Eulerian and profiling methods have been discussed. Although the first acoustic Doppler current meter has been...

  20. A review of zoonotic disease surveillance supported by the Armed Forces Health Surveillance Center.

    Science.gov (United States)

    Burke, R L; Kronmann, K C; Daniels, C C; Meyers, M; Byarugaba, D K; Dueger, E; Klein, T A; Evans, B P; Vest, K G

    2012-05-01

    The Armed Forces Health Surveillance Center (AFHSC), Division of Global Emerging Infections Surveillance and Response System conducts disease surveillance through a global network of US Department of Defense research laboratories and partnerships with foreign ministries of agriculture, health and livestock development in over 90 countries worldwide. In 2010, AFHSC supported zoonosis survey efforts were organized into four main categories: (i) development of field assays for animal disease surveillance during deployments and in resource limited environments, (ii) determining zoonotic disease prevalence in high-contact species which may serve as important reservoirs of diseases and sources of transmission, (iii) surveillance in high-risk human populations which are more likely to become exposed and subsequently infected with zoonotic pathogens and (iv) surveillance at the human-animal interface examining zoonotic disease prevalence and transmission within and between human and animal populations. These efforts have aided in the detection, identification and quantification of the burden of zoonotic diseases such as anthrax, brucellosis, Crimean Congo haemorrhagic fever, dengue fever, Hantaan virus, influenza, Lassa fever, leptospirosis, melioidosis, Q fever, Rift Valley fever, sandfly fever Sicilian virus, sandfly fever Naples virus, tuberculosis and West Nile virus, which are of military and public health importance. Future zoonotic surveillance efforts will seek to develop local capacity for zoonotic surveillance focusing on high risk populations at the human-animal interface.

  1. Weighing in on Surveillance: Perception of the Impact of Surveillance on Female Ballet Dancers' Health

    Science.gov (United States)

    Dryburgh, Anne; Fortin, Sylvie

    2010-01-01

    The aim of this qualitative study was to investigate professional ballet dancers' perceptions of the impact of surveillance on their psychological and physical health. The theoretical framework was inspired by Foucault's writing, particularly his concepts of surveillance, power, discipline and docile bodies. Fifteen professional ballet dancers…

  2. Weighing in on Surveillance: Perception of the Impact of Surveillance on Female Ballet Dancers' Health

    Science.gov (United States)

    Dryburgh, Anne; Fortin, Sylvie

    2010-01-01

    The aim of this qualitative study was to investigate professional ballet dancers' perceptions of the impact of surveillance on their psychological and physical health. The theoretical framework was inspired by Foucault's writing, particularly his concepts of surveillance, power, discipline and docile bodies. Fifteen professional ballet dancers…

  3. Economics of zoonoses surveillance in a 'One Health' context: an assessment of Campylobacter surveillance in Switzerland.

    Science.gov (United States)

    Babo Martins, S; Rushton, J; Stärk, K D C

    2017-04-01

    Cross-sectorial surveillance and general collaboration between the animal and the public health sectors are increasingly recognized as needed to better manage the impacts of zoonoses. From 2009, the Swiss established a Campylobacter mitigation system that includes human and poultry surveillance data-sharing within a multi-sectorial platform, in a 'One Health' approach. The objective of this study was to explore the economics of this cross-sectorial approach, including surveillance and triggered interventions. Costs and benefits of the One Health and of the uni-sectorial approach to Campylobacter surveillance were identified using an economic assessment framework developed earlier. Cost information of surveillance activities and interventions was gathered and disability-adjusted life years (DALYs) associated with the disease estimated for 2008 and 2013. In the first 5 years of this One Health approach to Campylobacter mitigation, surveillance contributed with information mainly used to perform risk assessments, monitor trends and shape research efforts on Campylobacter. There was an increase in costs associated with the mitigation activities following integration, due mainly to the allocation of additional resources to research and implementation of poultry surveillance. The overall burden of campylobacteriosis increased by 3·4-8·8% to 1751-2852 DALYs in 2013. In the timing of the analysis, added value associated with this cross-sectorial approach to surveillance of Campylobacter in the country was likely generated through non-measurable benefits such as intellectual capital and social capital.

  4. Unforeseen costs of cutting mosquito surveillance budgets.

    Directory of Open Access Journals (Sweden)

    Gonzalo M Vazquez-Prokopec

    Full Text Available A budget proposal to stop the U.S. Centers for Disease Control and Prevention (CDC funding in surveillance and research for mosquito-borne diseases such as dengue and West Nile virus has the potential to leave the country ill-prepared to handle new emerging diseases and manage existing ones. In order to demonstrate the consequences of such a measure, if implemented, we evaluated the impact of delayed control responses to dengue epidemics (a likely scenario emerging from the proposed CDC budget cut in an economically developed urban environment. We used a mathematical model to generate hypothetical scenarios of delayed response to a dengue introduction (a consequence of halted mosquito surveillance in the City of Cairns, Queensland, Australia. We then coupled the results of such a model with mosquito surveillance and case management costs to estimate the cumulative costs of each response scenario. Our study shows that halting mosquito surveillance can increase the management costs of epidemics by up to an order of magnitude in comparison to a strategy with sustained surveillance and early case detection. Our analysis shows that the total costs of preparedness through surveillance are far lower than the ones needed to respond to the introduction of vector-borne pathogens, even without consideration of the cost in human lives and well-being. More specifically, our findings provide a science-based justification for the re-assessment of the current proposal to slash the budget of the CDC vector-borne diseases program, and emphasize the need for improved and sustainable systems for vector-borne disease surveillance.

  5. Organization of surveillance in GI practice.

    Science.gov (United States)

    Senore, Carlo; Bellisario, Cristina; Hassan, Cesare

    2016-12-01

    Several reports documented an inefficient utilisation of available resources, as well as a suboptimal compliance with surveillance recommendations. Although, evidence suggests that organisational issues can influence the quality of care delivered, surveillance protocols are usually based on non-organized approaches. We conducted a literature search (publication date: 01/2000-06/2016) on PubMed and Cochrane Database of Systematic Reviews, Database of Abstracts of Reviews of Effects and Cochrane Central Register of Controlled Trials for guidelines, or consensus statements, for surveys of practice, reporting information about patients, or providers attitudes and behaviours, for intervention studies to enhance compliance with guidelines. Related articles were also scrutinised. Based on the clinical relevance and burden on endoscopy services this review was focused on surveillance for Barrett's oesophagus, IBD and post-polypectomy surveillance of colonic adenomas. Existing guidelines are generally recognising structure and process requirements influencing delivery of surveillance interventions, while less attention had been devoted to transitions and interfaces in the care process. Available evidence from practice surveys is suggesting the need to design organizational strategies aimed to enable patients to attend and providers to deliver timely and appropriate care. Well designed studies assessing the effectiveness of specific interventions in this setting are however lacking. Indirect evidence from screening settings would suggest that the implementation of automated standardized recall systems, utilisation of clinical registries, removing financial barriers, could improve appropriateness of use and compliance with recommendations. Lack of sound evidence regarding utility and methodology of surveillance can contribute to explain the observed variability in providers and patients attitudes and in compliance with the recommended surveillance. Copyright © 2016 Elsevier

  6. Using Poison Center Data for Postdisaster Surveillance

    Science.gov (United States)

    Wolkin, Amy; Schnall, Amy H.; Law, Royal; Schier, Joshua

    2015-01-01

    The role of public health surveillance in disaster response continues to expand as timely, accurate information is needed to mitigate the impact of disasters. Health surveillance after a disaster involves the rapid assessment of the distribution and determinants of disaster-related deaths, illnesses, and injuries in the affected population. Public health disaster surveillance is one mechanism that can provide information to identify health problems faced by the affected population, establish priorities for decision makers, and target interventions to meet specific needs. Public health surveillance traditionally relies on a wide variety of data sources and methods. Poison center (PC) data can serve as data sources of chemical exposures and poisonings during a disaster. In the US, a system of 57 regional PCs serves the entire population. Poison centers respond to poison-related questions from the public, health care professionals, and public health agencies. The Centers for Disease Control and Prevention (CDC) uses PC data during disasters for surveillance of disaster-related toxic exposures and associated illnesses to enhance situational awareness during disaster response and recovery. Poison center data can also be leveraged during a disaster by local and state public health to supplement existing surveillance systems. Augmenting traditional surveillance data (ie, emergency room visits and death records) with other data sources, such as PCs, allows for better characterization of disaster-related morbidity and mortality. Poison center data can be used during a disaster to detect outbreaks, monitor trends, track particular exposures, and characterize the epidemiology of the event. This timely and accurate information can be used to inform public health decision making during a disaster and mitigate future disaster-related morbidity and mortality. PMID:25205009

  7. Distributed data processing for public health surveillance

    Directory of Open Access Journals (Sweden)

    Yih Katherine

    2006-09-01

    Full Text Available Abstract Background Many systems for routine public health surveillance rely on centralized collection of potentially identifiable, individual, identifiable personal health information (PHI records. Although individual, identifiable patient records are essential for conditions for which there is mandated reporting, such as tuberculosis or sexually transmitted diseases, they are not routinely required for effective syndromic surveillance. Public concern about the routine collection of large quantities of PHI to support non-traditional public health functions may make alternative surveillance methods that do not rely on centralized identifiable PHI databases increasingly desirable. Methods The National Bioterrorism Syndromic Surveillance Demonstration Program (NDP is an example of one alternative model. All PHI in this system is initially processed within the secured infrastructure of the health care provider that collects and holds the data, using uniform software distributed and supported by the NDP. Only highly aggregated count data is transferred to the datacenter for statistical processing and display. Results Detailed, patient level information is readily available to the health care provider to elucidate signals observed in the aggregated data, or for ad hoc queries. We briefly describe the benefits and disadvantages associated with this distributed processing model for routine automated syndromic surveillance. Conclusion For well-defined surveillance requirements, the model can be successfully deployed with very low risk of inadvertent disclosure of PHI – a feature that may make participation in surveillance systems more feasible for organizations and more appealing to the individuals whose PHI they hold. It is possible to design and implement distributed systems to support non-routine public health needs if required.

  8. SAVY-4000 Field Surveillance Plan Update for 2017

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, Elizabeth J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Stone, Timothy Amos [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Smith, Paul Herrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Reeves, Kirk Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Veirs, Douglas Kirk [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Prochnow, David Adrian [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-20

    The Packaging Surveillance Program section of the Department of Energy (DOE) Manual 441.1-­1, Nuclear Material Packaging Manual (DOE 2008), requires DOE contractors to “ensure that a surveillance program is established and implemented to ensure the nuclear material storage package continues to meet its design criteria.”This 2017 update reflects changes to the surveillance plan resulting from surveillance findings as documented in Reeves et al. 2016. These findings include observations of corrosion in SAVY and Hagan containers and the indication (in one SAVY container) of possible filter membrane thermal degradation. This surveillance plan update documents the rationale for selecting surveillance containers, specifies the containers for 2017 surveillance, and identifies a minimum set of containers for 2018 surveillance. This update contains important changes to the previous surveillance plans.

  9. Effective surveillance for homeland security balancing technology and social issues

    CERN Document Server

    Flammini, Francesco; Franceschetti, Giorgio

    2013-01-01

    Effective Surveillance for Homeland Security: Balancing Technology and Social Issues provides a comprehensive survey of state-of-the-art methods and tools for the surveillance and protection of citizens and critical infrastructures against natural and deliberate threats. Focusing on current technological challenges involving multi-disciplinary problem analysis and systems engineering approaches, it provides an overview of the most relevant aspects of surveillance systems in the framework of homeland security. Addressing both advanced surveillance technologies and the related socio-ethical issues, the book consists of 21 chapters written by international experts from the various sectors of homeland security. Part I, Surveillance and Society, focuses on the societal dimension of surveillance-stressing the importance of societal acceptability as a precondition to any surveillance system. Part II, Physical and Cyber Surveillance, presents advanced technologies for surveillance. It considers developing technologie...

  10. Surveillance issues in inflammatory bowel disease: ulcerative colitis.

    Science.gov (United States)

    Provenzale, D; Onken, J

    2001-02-01

    This review article on the surveillance of patients with ulcerative colitis provides an overview of the criteria for evaluating screening and surveillance programs and applies the criteria to the available evidence to determine the effectiveness of the surveillance of patients with ulcerative colitis. We examine the clinical outcomes associated with surveillance, the additional clinical time required to confirm the diagnosis of dysplasia and cancer, compliance with surveillance and follow-up, and the effectiveness of the individual components of a surveillance program, including colonoscopy and pathologist's interpretation. The disability associated with colectomy is considered, as are the cost and acceptability of surveillance programs. Patients with long-standing ulcerative colitis are at risk for developing colorectal cancer. Recommended surveillance colonoscopy should be supported. New endoscopic and histopathologic techniques to improve the identification of high-risk patients may enhance the effectiveness and cost-effectiveness of surveillance practices.

  11. Anomaly Detection In Additively Manufactured Parts Using Laser Doppler Vibrometery

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, Carlos A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-09-29

    Additively manufactured parts are susceptible to non-uniform structure caused by the unique manufacturing process. This can lead to structural weakness or catastrophic failure. Using laser Doppler vibrometry and frequency response analysis, non-contact detection of anomalies in additively manufactured parts may be possible. Preliminary tests show promise for small scale detection, but more future work is necessary.

  12. Radar Micro-Doppler classification of Mini-UAVs

    NARCIS (Netherlands)

    Harmanny, R.L.A.; Prémel-Cabic, G.; Wit, J.J.M.

    2015-01-01

    The radar micro-Doppler signature of a target depends on its micro-motion, i.e., the motion of parts of a target relative to the motion of the target as a whole. These micro-motions are very characteristic considering different target classes, e.g., the slow pendulum-like motion of a bird’s wings ve

  13. High-resolution kinetic energy distributions via doppler shift measurements

    Science.gov (United States)

    Xu, Z.; Koplitz, B.; Buelow, S.; Baugh, D.; Wittig, C.

    1986-07-01

    In photolysis/probe experiments using pulsed sources, time delay produces both spatial and directional bias in the fragment distributions, thus enabling well-resolved kinetic energy distributions to be obtained from Doppler shift measurements. Data are presented for H-atoms detected using two-photon ionization, and high S/N and laser-limited kinetic energy resolution are demonstrated.

  14. ATTITUDE RATE ESTIMATION BY GPS DOPPLER SIGNAL PROCESSING

    Institute of Scientific and Technical Information of China (English)

    He Side; Milos Doroslovacki; Guo Zhenyu; Zhang Yufeng

    2003-01-01

    A method is presented for near-Earth spacecraft or aviation vehicle's attitude rate estimation by using relative Doppler frequency shift of the Global Positioning System (GPS)carrier. It comprises two GPS receiving antennas, a signal processing circuit and an algorithm.The whole system is relatively simple, the cost and wcight, as well as power consumption, are very low.

  15. New Type of 2-D Laser Doppler Vibrometer

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The fundamentals and method of 2-D laser Doppler vibrometer are introduced.The factors influencing the measuring accuracy are analyzed. Moreover, the circuit for signal processing is designed. The vibrating amplitude and frequency of 2-D vibration in wider range can be measured simultaneously in non-contact means,the measuring results are accurate.

  16. Diagnostic sensitivity and specificity of Doppler ultrasound in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Terslev, L.; Recke, P. von der; Torp-Pedersen, S.

    2008-01-01

    Objective. To evaluate the sensitivity and specificity of Doppler ultrasound (DUS) in diagnosing arthritis in the wrist and hands, and, if possible, to define a cutoff level for our ultrasound measures for inflammation, resistive index (RI), and color fraction. Methods. Using DUS, 88 patients...

  17. Noise Studies of Externally Dispersed Interferometry for Doppler Velocimetry

    Energy Technology Data Exchange (ETDEWEB)

    Erskine, D J; Edelstein, J; Lloyd, J; Muirhead, P

    2006-05-04

    Externally Dispersed Interferometry (EDI) is the series combination of a fixed-delay field-widened Michelson interferometer with a dispersive spectrograph. This combination boosts the spectrograph performance for both Doppler velocimetry and high resolution spectroscopy. The interferometer creates a periodic comb that multiplies against the input spectrum to create moire fringes, which are recorded in combination with the regular spectrum. Both regular and high-frequency spectral components can be recovered from the data--the moire component carries additional information that increases the signal to noise for velocimetry and spectroscopy. Here we present simulations and theoretical studies of the photon limited Doppler velocity noise in an EDI. We used a model spectrum of a 1600K temperature star. For several rotational blurring velocities 0, 7.5, 15 and 25 km/s we calculated the dimensionless Doppler quality index (Q) versus wavenumber v. This is the normalized RMS of the derivative of the spectrum and is proportional to the photon-limited Doppler signal to noise ratio.

  18. Excitonic Doppler-Rabi Oscillations in a Moving Organic Slab

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    It is theoretically shown that excitonic Doppler-Rabi oscillations can occur in an organic slab moving along the axis of a high-Q cavity. Due to the √N enhancement of the vacuum Rabi frequency, this effect can be more easily observed than that in a moving two-level atom.

  19. Color Doppler in the Assessment of Uteroplacental Circulation Insufficiency

    Directory of Open Access Journals (Sweden)

    Ahmad Soltani Shirazi

    2010-05-01

    Full Text Available Usage of color Doppler ultrasound in the diagnosis of uteroplacental or fetal-placental vascular insufficiency is based on the theory that many of these insufficiencies are due to small vessel disease in the uteroplacental or fetal-placental vasculature which ultimately results in fetal intrauterine growth retardation, increase in prenatal mortality and morbidity and fetal neurological development. "nIn a prospective study on patients who were sus-pected for developing uteroplacental insufficiency, color Doppler ultrasound was done and the results were compared with neonatal weight (one of the most important criteria for IUGR determination which was measured just after delivery."nDirect significant relation was showed to be present between prepartum vascular changes detected in Doppler ultrasound and prognosis of IUGR. "nThree vessel types were assessed in this study:"n1. Umbilical-middle cerebral arteries"n2. Uterine arteries"n3.Venous system (umbilical, ductus venosus, IVC, which is used to assess the compensation process in fetal circulation."nThree Doppler indices of vascular resistance were studied and their abnormalities according to the age of pregnancy were assessed.

  20. Tethered acoustic doppler current profiler platforms for measuring streamflow

    Science.gov (United States)

    Rehmel, Michael S.; Stewart, James A.; Morlock, Scott E.

    2003-01-01

    The U.S. Geological Survey tested and refined tethered-platform designs for measuring streamflow. Platform specifications were developed, radio-modem telemetry of acoustic Doppler current profiler (ADCP) data and potential platform-hull sources were investigated, and hulls were tested and evaluated.

  1. Study of an airborne Doppler radar: Project Asterix

    Science.gov (United States)

    Testud, Jacques; Baudin, F.; Amayenc, P.

    Specifications for an airborne Doppler radar for meteorological applications are given. The following areas are covered: (1) principle for measuring three-dimensional speed field; (2) pulse pattern and detectability; (3) antenna; (4) processing of data; (5) analog system; (6) data control and recording; (7) attitude control and vibrations; and (8) logistics.

  2. Airborne Wind Profiling Algorithm for Doppler Wind LIDAR

    Science.gov (United States)

    Beyon, Jeffrey Y. (Inventor); Koch, Grady J. (Inventor); Kavaya, Michael J. (Inventor)

    2015-01-01

    Systems, methods, and devices of the present invention enable airborne Doppler Wind LIDAR system measurements and INS/GPS measurements to be combined to estimate wind parameters and compensate for instrument misalignment. In a further embodiment, the wind speed and wind direction may be computed based on two orthogonal line-of-sight LIDAR returns.

  3. Radar Micro-Doppler classification of Mini-UAVs

    NARCIS (Netherlands)

    Harmanny, R.L.A.; Prémel-Cabic, G.; Wit, J.J.M.

    2015-01-01

    The radar micro-Doppler signature of a target depends on its micro-motion, i.e., the motion of parts of a target relative to the motion of the target as a whole. These micro-motions are very characteristic considering different target classes, e.g., the slow pendulum-like motion of a bird’s wings

  4. Asymmetric micro-Doppler frequency comb generation via magnetoelectric coupling

    Science.gov (United States)

    Filonov, Dmitry; Steinberg, Ben Z.; Ginzburg, Pavel

    2017-06-01

    Electromagnetic scattering from moving bodies, being an inherently time-dependent phenomenon, gives rise to a generation of new frequencies, which can be used to characterize the motion. Whereas an ordinary motion along a linear path produces a constant Doppler shift, an accelerated scatterer can generate a micro-Doppler frequency comb. The spectra produced by rotating objects were studied and observed in a bistatic lock-in detection scheme. The internal geometry of a scatterer was shown to determine the spectrum, and the degree of structural asymmetry was suggested to be identified via signatures in the micro-Doppler comb. In particular, hybrid magnetoelectric particles, showing an ultimate degree of asymmetry in forward and backward scattering directions, were investigated. It was shown that the comb in the backward direction has signatures at the fundamental rotation frequency and its odd harmonics, whereas the comb of the forward scattered field has a prevailing peak at the doubled frequency and its multiples. Additional features of the comb were shown to be affected by the dimensions of the particle and by the strength of the magnetoelectric coupling. Experimental verification was performed with a printed circuit board antenna based on a wire and a split ring, while the structure was illuminated at a 2 GHz carrier frequency. Detailed analysis of micro-Doppler combs enables remote detection of asymmetric features of distant objects and could find use in a span of applications, including stellar radiometry and radio identification.

  5. A simplified study of trans-mitral Doppler patterns

    Directory of Open Access Journals (Sweden)

    Thomas George

    2008-11-01

    Full Text Available Abstract Background Trans-mitral Doppler produces complex patterns with a great deal of variability. There are several confusing numerical measures and indices to study these patterns. However trans-mitral Doppler produces readymade data visualization by pattern generation which could be interpreted by pattern analysis. By following a systematic approach we could create an order and use this tool to study cardiac function. Presentation of the hypothesis In this new approach we eliminate the variables and apply pattern recognition as the main criterion of study. Proper terminologies are also devised to avoid confusion. In this way we can get some meaningful information. Testing the hypothesis Trans-mitral Doppler should be seen as patterns rather than the amplitude. The hypothesis can be proven by logical deduction, extrapolation and elimination of variables. Trans-mitral flow is also analyzed vis-à-vis the Starling's Law applied to the left atrium. Implications of the hypothesis Trans-mitral Doppler patterns are not just useful for evaluating diastolic function. They are also useful to evaluate systolic function. By following this schema we could get useful diagnostic information and therapeutic options using simple pattern recognition with minimal measurements. This simplified but practical approach will be useful in day to day clinical practice and help in understanding cardiac function better. This will also standardize research and improve communication.

  6. A compact differential laser Doppler velocimeter using a semiconductor laser

    NARCIS (Netherlands)

    Jentink, H.W.; Beurden, van J.A.J.; Helsdingen, M.A.; Mul, de F.F.M.; Suichies, H.E.; Aarnoudse, J.G.; Greve, J.

    1987-01-01

    A small differential laser Doppler velocimeter which uses a semiconductor laser and a small number of optical components is described. In this device the light from the laser diode is split into coherent beams by means of a diffraction grating. The two first-order beams are crossed in a probe volume

  7. Laser Doppler velocimetry in Microchannels using integrated optical waveguides.

    NARCIS (Netherlands)

    Pandraud, G.; van den Berg, Albert; Semenov, S.N.

    2000-01-01

    The possibility of laser Doppler velocimetry (LDV) in microchannels, where particles are suspended in a liquid, and where oscillating or evanescent guided coherent light wave is present, is examined theoretically. The conditions for the observation of the transverse and longitudinal collective phore

  8. UTEROPLACENTAL DOPPLER VELOCIMETRY DURING BRAXTON-HICKS CONTRACTIONS

    NARCIS (Netherlands)

    DIJKSTRA, K; AARNOUDSE, JG; Oosterhof, H.

    1992-01-01

    Pulsed-wave Doppler ultrasound was used to evaluate the influence of Braxton Hicks' contractions on flow velocity waveforms in the uterine arteries. Flow velocity waveforms were obtained from a standardized site, at the crossing of the uterine artery with the external iliac artery near the uterine w

  9. Transcranial Doppler for detection of cerebral ischaemia during carotid endarterectomy

    DEFF Research Database (Denmark)

    Jørgensen, L G; Schroeder, T V

    1992-01-01

    We evaluated transcranial Doppler sonography (TCD) for the detection of cerebral ischaemia during carotid endarterectomy in 30 male and 14 female patients with ipsilateral focal cerebro-vascular symptoms. Surgery was performed during halothane-nitrous oxide anaesthesia with moderate hypocapnia...

  10. Color M-mode and pulsed wave tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H;

    2001-01-01

    To assess the association between color M-mode flow propagation velocity and the early diastolic mitral annular velocity (E(m)) obtained with tissue Doppler echocardiography and to assess the prognostic implications of the indexes, echocardiography was performed on days 1 and 5, and 1 and 3 months...

  11. Ultrasonography and color Doppler in juvenile idiopathic arthritis

    DEFF Research Database (Denmark)

    Laurell, Louise; Court-Payen, Michel; Nielsen, Susan;

    2012-01-01

    The wrist region is one of the most complex joints of the human body. It is prone to deformity and functional impairment in juvenile idiopathic arthritis (JIA), and is difficult to examine clinically. The aim of this study was to evaluate the role of ultrasonography (US) with Doppler in diagnosis...

  12. Review of methodological developments in laser Doppler flowmetry

    NARCIS (Netherlands)

    Rajan, Vinayakrishnan; Varghese, Babu; van Leeuwen, Ton; Steenbergen, Wiendelt

    2009-01-01

    Laser Doppler flowmetry is a non-invasive method of measuring microcirculatory blood flow in tissue. In this review the technique is discussed in detail. The theoretical and experimental developments to improve the technique are reviewed. The limitations of the method are elaborated upon, and the re

  13. Venstre ventrikels diastoliske funktion vurderet med transtorakal Doppler-ekkokardiografi

    DEFF Research Database (Denmark)

    Poulsen, S H; Jensen, S E; Gøtzsche, O;

    1996-01-01

    Left ventricular diastolic dysfunction is currently recognized in patients with different heart diseases. Three abnormal filling patterns of the left ventricle detected by pulsed-Doppler echocardiography are observed in patients with heart disease. Each filling pattern is characterised by differe...

  14. Color doppler in diagnosis of pathological changes in blood vessels

    Directory of Open Access Journals (Sweden)

    Mladenović Saša

    2014-01-01

    Full Text Available Color Doppler ultrasound is a method that allows noninvasive imaging of blood flow through a blood vessel and analysis of blood vessels, which can be made to flow disturbance and the presence of plaque and narrowing of the blood vessel. Color Doppler ultrasonography allows early detection of pathological changes in blood vessels, which contributes to adequate preventive and therapeutic procedures in the prevention of cerebrovascular disorders. The aim of this paper is to demonstrate the importance of color Doppler ultrasound blood vessels in the diagnosis of pathological changes in the blood vessels of the neck. To create a work used the material of the Cabinet of color Doppler ultrasonography of the Health Center in Donja Gusterica in a prospective study of a random sample of 60 patients were reviewed in January 2014. Gender analysis examined patients, women were 32 (53.33% and 28 men (46.67%. Looking at the age of examined patients, we have found that most of them 43 (71.67% over the age of 50 years, while we found 17 (28.33% patients under 50 years. Atherosclerotic plaques were diagnosed in 36, a change in the shape of the carotid arteries in 29 patients. Atherosclerotic plaque, we usually find the bifurcation ACC and the Origin ACI in 23 (63.89%. Duplex sonography shows what angioneurologists and vascular surgeons are most interested in: the morphology of arterial lesions and hemodynamic effects.

  15. A Reference Optical System of Laser Doppler Longitudinal Displacement Measurement

    Institute of Scientific and Technical Information of China (English)

    张存满; 赵洋; 李达成

    2001-01-01

    In this paper, a new reference optical system is put forward to achieve longitudinal displacement measurement. An optical grating is used for frequency mixing and getting high SNR signals in the measurement. Conditions and methods for getting Doppler beat signals are presented.The experiments indicate that this optical syetem can be used to measure the longitudinal displacement with high accuracy.

  16. Doppler velocimetry with emphasis on the fetal cerebral circulation

    NARCIS (Netherlands)

    M.J. Noordam (Marja)

    1996-01-01

    textabstractIn this thesis the following questions were addressed: 1. Are changes in placental vascular resistance associated with alterations in arterial down stream impedance at fetal level? To this purpose placental embolization was carried-out in the fetal lamb with subsequent Doppler velocimetr

  17. Complex Doppler effect in left-handed metamaterials

    CERN Document Server

    Ziemkiewicz, David

    2014-01-01

    The Doppler shift is investigated in one-dimensional system with moving source. Theoretical findings are confirmed in numerical simulations of optical and acoustical waves propagation in simple metamaterial model, showing the reversed shift and the existence of multiple frequency modes. The properties of these waves are discussed. The effect of absorption on the phenomenon is outlined.

  18. Augmented Reality Based Doppler Lidar Data Visualization: Promises and Challenges

    Directory of Open Access Journals (Sweden)

    Cherukuru N. W.

    2016-01-01

    As a proof of concept, we used the lidar data from a recent field campaign and developed a smartphone application to view the lidar scan in augmented reality. In this paper, we give a brief methodology of this feasibility study, present the challenges and promises of using AR technology in conjunction with Doppler wind lidars.

  19. Usefulness of Doppler Parameter in Patients with Renal Transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yeo Chang; Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of); Park, Mi Hyun [Dept. of Radiology, Dankook University Hospital, Cheonan (Korea, Republic of); Kim, Ho Jun [Dept. of Radiology, Konyang University Hospital, Daejeon (Korea, Republic of)

    2012-08-15

    The purpose of this study is to assess the usefulness of Doppler parameters in transplanted kidney function. Doppler parameters, including resistive index (RI), pulsatility index (PI), peak systolic velocity (PSV), and end diastolic velocity (EDV) were measured in the interlobar artery of 55 transplant recipients. Patients were grouped according to glomerular filtration rate (GFR): Group A (GFR < 30 ml / min / 1.73 m2, n = 27) and group B (GFR {>=}30 ml / min / 1.73 m2, n = 28). Doppler parameters were compared between groups and correlated with the GFR. GFR (40.1 {+-} 26.9) showed a significant negative correlation with RI (0.69{+-}.08) (p = .002, r = -.414). RI (0.72 vs. 0.67), PI (1.42 vs. 1.23), and EDV (10.5 vs. 15.3) differed significantly between groups (p < .05), however, PSV was not (36.9 vs. 47.1). Patients in group A (n = 11) with a lower RI than the mean had significantly lower PSV (31.7 vs. 45.1; p = .027) and EDV (11.1 vs. 16.7; p .017), compared with such patients in group B (n = 21). Doppler parameters are useful for evaluation of function of transplanted kidney. Even if the RI is normal, PSV and EDV may be used as hemodynamic indicators.

  20. A range-rate extraction unit for determining Doppler effect

    Science.gov (United States)

    1970-01-01

    Active ranging technique devised for VHF or S-band radar systems divides target Doppler frequency by counter-generated number that is proportional to transmitting frequency, thus producing target velocity data in terms of speed and distance relative to target transponder.

  1. How to Study the Doppler Effect with Audacity Software

    Science.gov (United States)

    Dias, Marco Adriano; Carvalho, Paulo Simeão; Ventura, Daniel Rodrigues

    2016-01-01

    The Doppler effect is one of the recurring themes in college and high school classes. In order to contextualize the topic and engage the students in their own learning process, we propose a simple and easily accessible activity, i.e. the analysis of the videos available on the internet by the students. The sound of the engine of the vehicle…

  2. Unidirectional Rotation of Molecules Measured by the Rotational Doppler Effect

    Directory of Open Access Journals (Sweden)

    Prior Yehiam

    2013-03-01

    Full Text Available A pair of linearly polarized pump pulses induce field-free unidirectional molecular rotation, which is detected by a delayed circularly polarized probe. The polarization and spectrum of the probe are modified by the interaction with the molecules, in accordance with the Rotational Doppler Effect.

  3. Determining the Speed of Sound Using the Doppler Effect.

    Science.gov (United States)

    Gagne, Richard.

    1996-01-01

    Presents a simple but effective experiment that uses ultrasonic transducers and some basic electronics to study the speed of sound using the Doppler effect. Eliminates the noise problems associated with most sound experiments. Discusses the theory, and describes the apparatus and procedure. (JRH)

  4. Maternal and fetal Doppler velocimetry in women diagnosed with ...

    African Journals Online (AJOL)

    2016-03-16

    Mar 16, 2016 ... Aim: This study aimed to investigate maternal and fetal Doppler flow parameters in term pregnant women diagnosed with fear of ... [3] A strong association was found between FOC ... and it includes 33 items about women's cognitive appraisal .... acute emotional reactivity during pregnancy can influence.

  5. Doppler Lidar in the Wind Forecast Improvement Projects

    Directory of Open Access Journals (Sweden)

    Pichugina Yelena

    2016-01-01

    Full Text Available This paper will provide an overview of some projects in support of Wind Energy development involving Doppler lidar measurement of wind flow profiles. The high temporal and vertical resolution of these profiles allows the uncertainty of Numerical Weather Prediction models to be evaluated in forecasting dynamic processes and wind flow phenomena in the layer of rotor-blade operation.

  6. Doppler Lidar in the Wind Forecast Improvement Projects

    Science.gov (United States)

    Pichugina, Yelena; Banta, Robert; Brewer, Alan; Choukulkar, Aditya; Marquis, Melinda; Olson, Joe; Hardesty, Mike

    2016-06-01

    This paper will provide an overview of some projects in support of Wind Energy development involving Doppler lidar measurement of wind flow profiles. The high temporal and vertical resolution of these profiles allows the uncertainty of Numerical Weather Prediction models to be evaluated in forecasting dynamic processes and wind flow phenomena in the layer of rotor-blade operation.

  7. High-Energy 2-Micrometers Doppler Lidar for Wind Measurements

    Science.gov (United States)

    Koch, Grady J.; Beyon, Jeffrey Y.; Barnes, Bruce W.; Petros, Mulugeta; Yu, Jirong; Amzajerdian, Farzin; Kavaya, Michael J.; Singh, Upendra N.

    2006-01-01

    High-energy 2-micrometer wavelength lasers have been incorporated in a prototype coherent Doppler lidar to test component technologies and explore applications for remote sensing of the atmosphere. Design of the lidar is presented including aspects in the laser transmitter, receiver, photodetector, and signal processing. Calibration tests and sample atmospheric data are presented on wind and aerosol profiling.

  8. Validar: a testbed for advanced 2-micron Doppler lidar

    Science.gov (United States)

    Koch, Grady J.; Petros, Mulugeta; Barnes, Bruce W.; Beyon, Jeffrey Y.; Amzajerdian, Farzin; Yu, Jirong; Kavaya, Michael J.; Singh, Upendra N.

    2004-09-01

    High-energy 2-micron lasers have been incorporated in a breadboard coherent Doppler lidar to test component technologies and explore applications for remote sensing of the atmosphere. Design of the lidar is presented including aspects in the laser transmitter, receiver, photodetector, and signal processing. Sample data is presented on wind profiling and CO2 concentration measurements.

  9. Estimation of amputation level with a laser Doppler flowmeter

    DEFF Research Database (Denmark)

    Gebuhr, Peter Henrik; Jørgensen, J P; Vollmer-Larsen, B

    1989-01-01

    Leg amputation levels were decided in 24 patients suffering from atherosclerosis, using the conventional techniques of segmental blood pressure and radioisotope skin clearance. The skin microcirculation was measured and recorded before operation with a laser doppler flowmeter. A high correlation...... was found between the successful amputation levels and the maximal blood perfusion of the skin measured in this way....

  10. Path-length-resolved optical Doppler perfusion monitoring

    NARCIS (Netherlands)

    Varghese, Babu; Rajan, Vinayakrishnan; Leeuwen, van Ton G.; Steenbergen, Wiendelt

    2007-01-01

    We report the first path-length-resolved perfusion measurements on human skin measured with a phase-modulated low-coherence Mach-Zehnder interferometer with spatially separated fibers for illumination and detection. Optical path lengths of Doppler shifted and unshifted light and path-length-dependen

  11. Predictable progressive Doppler deterioration in IUGR: does it really exist?

    LENUS (Irish Health Repository)

    Unterscheider, Julia

    2013-12-01

    An objective of the Prospective Observational Trial to Optimize Pediatric Health in IUGR (PORTO) study was to evaluate multivessel Doppler changes in a large cohort of intrauterine growth restriction (IUGR) fetuses to establish whether a predictable progressive sequence of Doppler deterioration exists and to correlate these Doppler findings with respective perinatal outcomes.

  12. Radar micro-Doppler of wind turbines: Simulation and analysis using rotating linear wire structures

    NARCIS (Netherlands)

    Krasnov, O.A.; Yarovoy, A.

    2015-01-01

    A simple electromagnetic model of wind-turbine's main structural elements as the linear wired structures is developed to simulate the temporal patterns of observed radar return Doppler spectra (micro-Doppler). Using the model, the micro-Doppler for different combinations of the turbines rotation

  13. Classification of Small UAVs and Birds by Micro-Doppler Signatures

    NARCIS (Netherlands)

    Molchanov, P.; Egiazarian, K.; Astola, J.; Harmanny, R.I.A.; Wit, J.J.M. de

    2013-01-01

    The problem of unmanned aerial vehicles classification using continuous wave radar is considered in this paper. Classification features are extracted from micro-Doppler signature. Before the classification, the micro-Doppler signature is filtered and aligned to compensate the Doppler shift caused by

  14. Musculoskeletal colour/power Doppler in sports medicine: image parameters, artefacts, image interpretation and therapy

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, Mikael; Kønig, Merete Juhl

    2011-01-01

    guidelines and recommendations are based on personal experience since no evidence in literature exists. The basic technical background of Doppler ultrasound and typical artefacts will be discussed, in order to understand and interpret the Doppler result. Recommendations for the Doppler settings are given...

  15. Color Doppler Ultrasonography in Evaluation of the Postoperative Penis

    Directory of Open Access Journals (Sweden)

    M. Ghafouri

    2005-08-01

    Full Text Available Introduction & Background: Color Doppler ultrasonography (US is the imaging modality of choice in patients with penile diseases. Ultrasonography has a well-established role in evaluating erectile dysfunction as well as penile trauma, scarring, deformity, and tumors. The normal postoperative anatomy and the pathologic changes that can occur in cases of surgical complications can be successfully investigated with US. Gray Scale (B Mode and Color Doppler US clearly depicts the normal penile anatomy and postoperative changes. It is also effective in evaluating surgery-related complications and determining the causes of erectile dysfunction and other un-satisfactory long¬term results. Color Doppler US is the imaging modality of choice in evaluating patients who have undergone penile surgery. Here we aim to illustrate the gray-scale and color Doppler US appearance of normal penis, discuss the main penile surgical procedures, recognize the typical US features of the postopera-tive penis, and describe the US appearance of various postoperative complications. Patients & Methods: This article is the result of evaluating 42 patients referred to the radiology ward of Hashemi-Nejad Hospital, Iran University of Medical Sciences in the years 2002 to 2005 for ultrasonography of penis to assess the penis after different penile surgical procedures (urethral surgery, correction of penile mal-formations, prosthesis implantation, vascular surgery for impotence, surgical management of priapism, phallic reconstruction. The US apparatus was Esaote Technos MP, with linear multifrequency 5-8.5MHz. transducer. Results: A variety of early and late surgical complications could be identified, such as extraalbugineal patho-logic fluid collections and fibrosis. Moreover, Doppler US of the penile vessels and vascular anastomoses fol-lowing revascularization allowed direct evaluation of flow characteristics, shunt patency, and venous en-gorgement. Color Doppler US was also

  16. Role of Doppler Velocimetry in growth restricted fetuses

    Directory of Open Access Journals (Sweden)

    Dr. Khushali Gandhi

    2015-01-01

    Full Text Available Background Intra Uterine Growth Restriction (IUGR is an important and particularly challenging problem for obstetricians and pediatricians. IUGR is a leading contributor in perinatal morbidity and mortality affecting 23.8% newborns around the world and 75% are born in Asia alone. In India the incidence of low birth weight varies from 15 to 25% and more than 50% of them are IUGR. Methods The present article consists of a study of 100 cases of intrauterine growth restriction with periodic color Doppler during the period of 1st July 2011 to 30 th August, 2013 in Obstetrics and Gynecology Department of a tertiary care center. Detail history taken. General and obstetrical examination was done along with routine hematological and urine investigations. Ultrasound examination was done for growth, liquor and placental localization. Fetal well- being was assessed with Doppler studies and daily fetal movement count. Results In present study moderate to severe pregnancy induced hypertension (53.9% and lack of proper weight gain (23% are found to be the commonest causes of IUGR. Out of 69 IUGR cases having abnormal Doppler, about 63.8% had abnormality in uterine artery flow, 85.5% had abnormality in umbilical artery flow, 88.4% had abnormality in middle cerebral artery flow, 55% had abnormality in uterine and umbilical artery and 75.4% had abnormality in umbilical artery and MCA. Incidence of fetal demise (13% was higher in patients with abnormal Doppler flow compared to normal flow (3.2%. Surgical intervention in form of caesarean was required in 69.6% of patients with abnormal Doppler flow. Cerebro-placental ratio (CPR 1 where fetal demise is 2.6%. Incidence of AEDF/REDF ( Absent End Diastolic flow/Reversed End diastolic flow in IUGR was 8% that resulted in 50% loss of fetus. Conclusions Color Doppler is a useful mode to predict fetal outcome in IUGR. Color Doppler allows better understandings of hemodynamic changes in feto- placental and utero

  17. Veterinary surveillance laboratories: developing the training program.

    Science.gov (United States)

    Mitchell, Staci L; McCline, Katasha T; Hanfelt, Margery M

    2010-01-01

    The increased need and demand for onsite, frequent, rapid, and portable food and bottled water testing for indicators of microbiological and chemical agents led to the deployment of 2 laboratory veterinary equipment sets. A Surveillance Food Laboratory Program (SFLP) was developed to allow Veterinary Corps commanders to establish targeted testing programs to enhance food safety and wholesomeness, along with faster responses to food defense, suspected foodborne illness, and food/water risk assessment missions. To support the deployment of the veterinary equipment sets and the SFLP, 2 new functional courses were developed by the Department of Veterinary Science. The Surveillance Food Laboratory Technician Course teaches essential technical skills that include sample processing, assay methodologies, results review, and interpretation of results produced by these laboratories. The Surveillance Food Laboratory Manager Course, developed for designated managers of the laboratories and laboratory programs, teaches the skills critical to ensuring proper surveillance laboratory oversight, testing, evaluation of results, risk communication, and response to presumptive positive results produced by the laboratories. Together, the courses allowed for the successful deployment of the unique veterinary equipment sets, resulting in development of fully operational surveillance laboratories in support of food protection missions in every major theater of operations.

  18. Project Surveillance and Maintenance Plan. [UMTRA Project

    Energy Technology Data Exchange (ETDEWEB)

    1985-09-01

    The Project Surveillance and Maintenance Plan (PSMP) describes the procedures that will be used by the US Department of Energy (DOE), or other agency as designated by the President to verify that inactive uranium tailings disposal facilities remain in compliance with licensing requirements and US Environmental Protection Agency (EPA) standards for remedial actions. The PSMP will be used as a guide for the development of individual Site Surveillance and Maintenance Plans (part of a license application) for each of the UMTRA Project sites. The PSMP is not intended to provide minimum requirements but rather to provide guidance in the selection of surveillance measures. For example, the plan acknowledges that ground-water monitoring may or may not be required and provides the (guidance) to make this decision. The Site Surveillance and Maintenance Plans (SSMPs) will form the basis for the licensing of the long-term surveillance and maintenance of each UMTRA Project site by the NRC. Therefore, the PSMP is a key milestone in the licensing process of all UMTRA Project sites. The Project Licensing Plan (DOE, 1984a) describes the licensing process. 11 refs., 22 figs., 8 tabs.

  19. Surveillance and Resilience in Theory and Practice

    Directory of Open Access Journals (Sweden)

    Charles D. Raab

    2015-09-01

    Full Text Available Surveillance is often used as a tool in resilience strategies towards the threat posed by terrorist attacks and other serious crime. “Resilience” is a contested term with varying and ambiguous meaning in governmental, business and social discourses, and it is not clear how it relates to other terms that characterise processes or states of being. Resilience is often assumed to have positive connotations, but critics view it with great suspicion, regarding it as a neo-liberal governmental strategy. However, we argue that surveillance, introduced in the name of greater security, may itself erode social freedoms and public goods such as privacy, paradoxically requiring societal resilience, whether precautionary or in mitigation of the harms it causes to the public goods of free societies. This article develops new models and extends existing ones to describe resilience processes unfolding over time and in anticipation of, or in reaction to, adversities of different kinds and severity, and explores resilience both on the plane of abstract analysis and in the context of societal responses to mass surveillance. The article thus focuses upon surveillance as a special field for conceptual analysis and modelling of situations, and for evaluating contemporary developments in “surveillance societies”.

  20. Hydronephrosis and pregnancy: study with Doppler echography. Hidronefrosis y embarazo: estudio mediante ecografia Doppler

    Energy Technology Data Exchange (ETDEWEB)

    Ripolles Gonzalez, T.R.; Ambit Capdevilla, S.; Sanguesa Nebot, C.; Lazaro, S. de; Garcia Vila, J.H.; Belloch Ugarte, V.

    1993-01-01

    An 18-month study was performed to establish the normal intrarenal resistance index during pregnancy, in order to determine whether it differed significantly depending on the week of gestation or the degree of hydronephrosis. For this purpose , the flow velocity waves obtained in right kidney were analyzed in a group of 112 patients on the basis of 209 explorations. The kidneys were classified as grade 0,I,II, or III according to the degree of hydronephrosis. Doppler signal sampling was carried out at the level of the corticomedullary junction. From the results of the study it can be deduced that the index of intrarenal resistance during pregnancy is similar to that of the general population, that there are no significant differences among the groups with different degree of hydronephrosis and that the index does not vary according to the different weeks of gestation. These findings suggest that, during pregnancy, a pathological resistance index in a kidney should not be attributed to the physiological changes associated with normal gestation. (Author) 21 refs.

  1. Abortion Surveillance - United States, 2013.

    Science.gov (United States)

    Jatlaoui, Tara C; Ewing, Alexander; Mandel, Michele G; Simmons, Katharine B; Suchdev, Danielle B; Jamieson, Denise J; Pazol, Karen

    2016-11-25

    Since 1969, CDC has conducted abortion surveillance to document the number and characteristics of women obtaining legal induced abortions in the United States. 2013. Each year, CDC requests abortion data from the central health agencies of 52 reporting areas (the 50 states, the District of Columbia, and New York City). The reporting areas provide this information voluntarily. For 2013, data were received from 49 reporting areas. For trend analysis, abortion data were evaluated from 47 areas that reported data every year during 2004-2013. Census and natality data, respectively, were used to calculate abortion rates (number of abortions per 1,000 women) and ratios (number of abortions per 1,000 live births). A total of 664,435 abortions were reported to CDC for 2013. Of these abortions, 98.2% were from the 47 reporting areas that provided data every year during 2004-2013. Among these 47 reporting areas, the abortion rate for 2013 was 12.5 abortions per 1,000 women aged 15-44 years, and the abortion ratio was 200 abortions per 1,000 live births. From 2012 to 2013, the total number, rate, and ratio of reported abortions decreased 5%. From 2004 to 2013, the total number, rate, and ratio of reported abortions decreased 20%, 21%, and 17%, respectively. In 2013, all three measures reached their lowest level for the entire period of analysis (2004-2013). In 2013 and throughout the period of analysis, women in their 20s accounted for the majority of abortions and had the highest abortion rates; women in their 30s and older accounted for a much smaller percentage of abortions and had lower abortion rates. In 2013, women aged 20-24 and 25-29 years accounted for 32.7% and 25.9% of all abortions, respectively, and had abortion rates of 21.8 and 18.2 abortions per 1,000 women aged 20-24 and 25-29 years, respectively. In contrast, women aged 30-34, 35-39, and ≥40 years accounted for 16.8%, 9.2%, and 3.6% of all abortions, respectively, and had abortion rates of 11.8, 7.0, and 2

  2. Abortion Surveillance - United States, 2012.

    Science.gov (United States)

    Pazol, Karen; Creanga, Andreea A; Jamieson, Denise J

    2015-11-27

    Since 1969, CDC has conducted abortion surveillance to document the number and characteristics of women obtaining legal induced abortions in the United States. 2012. Each year, CDC requests abortion data from the central health agencies of 52 reporting areas (the 50 states, the District of Columbia, and New York City). The reporting areas provide this information voluntarily. For 2012, data were received from 49 reporting areas. For trend analysis, abortion data were evaluated from 47 areas that reported data every year during 2003-2012. Census and natality data, respectively, were used to calculate abortion rates (number of abortions per 1,000 women) and ratios (number of abortions per 1,000 live births). A total of 699,202 abortions were reported to CDC for 2012. Of these abortions, 98.4% were from the 47 reporting areas that provided data every year during 2003-2012. Among these same 47 reporting areas, the abortion rate for 2012 was 13.2 abortions per 1,000 women aged 15-44 years, and the abortion ratio was 210 abortions per 1,000 live births. From 2011 to 2012, the total number and ratio of reported abortions decreased 4% and the abortion rate decreased 5%. From 2003 to 2012, the total number, rate, and ratio of reported abortions decreased 17%, 18%, and 14%, respectively, and reached their lowest level in 2012 for the entire period of analysis (2003-2012). In 2012 and throughout the period of analysis, women in their 20s accounted for the majority of abortions and had the highest abortion rates; women in their 30s and older accounted for a much smaller percentage of abortions and had lower abortion rates. In 2012, women aged 20-24 and 25-29 years accounted for 32.8% and 25.4% of all abortions, respectively, and had abortion rates of 23.3 and 18.9 abortions per 1,000 women aged 20-24 and 25-29 years, respectively. In contrast, women aged 30-34, 35-39, and ≥40 years accounted for 16.4%, 9.1%, and 3.7% of all abortions, respectively, and had abortion rates of

  3. Market surveillance for the food industry

    DEFF Research Database (Denmark)

    Grunert, Klaus G.; Brunsø, Karen

    1993-01-01

    Executive Summary: 1. We define market surveillance as the collection of information about variables which will allow inferences about the attractiveness of a company's present and future offerings. The attractiveness, in turn, will depend on the value customers perceive in a product relative...... to competing products and relative to its price. Such information on determinants of value perception and costs can be used in the strategy formulation of the company. 2. We define a market surveillance system as a set of methods/instruments to regularly select, collect, and process data about a market and its...... actors, with the aim of detecting changes in those long-term trends, which are expected to influence the attractiveness of a company's present an future offerings. 3. Different types of market surveillance systems can be distinguished based on the actors it covers (distributors/end users...

  4. A comprehensive review on intelligent surveillance systems

    Directory of Open Access Journals (Sweden)

    Sutrisno Warsono Ibrahim

    2016-05-01

    Full Text Available Intelligent surveillance system (ISS has received growing attention due to the increasing demand on security and safety. ISS is able to automatically analyze image, video, audio or other type of surveillance data without or with limited human intervention. The recent developments in sensor devices, computer vision, and machine learning have an important role in enabling such intelligent system. This paper aims to provide general overview of intelligent surveillance system and discuss some possible sensor modalities and their fusion scenarios such as visible camera (CCTV, infrared camera, thermal camera and radar. This paper also discusses main processing steps in ISS: background-foreground segmentation, object detection and classification, tracking, and behavioral analysis.

  5. System for surveillance of spectral signals

    Science.gov (United States)

    Gross, Kenneth C.; Wegerich, Stephan W.; Criss-Puszkiewicz, Cynthia; Wilks, Alan D.

    2001-01-01

    A method and system for monitoring at least one of a system, a process and a data source. A method and system have been developed for carrying out surveillance, testing and modification of an ongoing process or other source of data, such as a spectroscopic examination. A signal from the system under surveillance is collected and compared with a reference signal, a frequency domain transformation carried out for the system signal and reference signal, a frequency domain difference function established. The process is then repeated until a full range of data is accumulated over the time domain and a SPRT sequential probability ratio test methodology applied to determine a three-dimensional surface plot characteristic of the operating state of the system under surveillance.

  6. Infectious diseases: Surveillance, genetic modification and simulation

    Science.gov (United States)

    Koh, H. L.; Teh, S.Y.; De Angelis, D. L.; Jiang, J.

    2011-01-01

    Infectious diseases such as influenza and dengue have the potential of becoming a worldwide pandemic that may exert immense pressures on existing medical infrastructures. Careful surveillance of these diseases, supported by consistent model simulations, provides a means for tracking the disease evolution. The integrated surveillance and simulation program is essential in devising effective early warning systems and in implementing efficient emergency preparedness and control measures. This paper presents a summary of simulation analysis on influenza A (H1N1) 2009 in Malaysia. This simulation analysis provides insightful lessons regarding how disease surveillance and simulation should be performed in the future. This paper briefly discusses the controversy over the experimental field release of genetically modified (GM) Aedes aegypti mosquito in Malaysia. Model simulations indicate that the proposed release of GM mosquitoes is neither a viable nor a sustainable control strategy. ?? 2011 WIT Press.

  7. Inferring epidemic network topology from surveillance data.

    Science.gov (United States)

    Wan, Xiang; Liu, Jiming; Cheung, William K; Tong, Tiejun

    2014-01-01

    The transmission of infectious diseases can be affected by many or even hidden factors, making it difficult to accurately predict when and where outbreaks may emerge. One approach at the moment is to develop and deploy surveillance systems in an effort to detect outbreaks as timely as possible. This enables policy makers to modify and implement strategies for the control of the transmission. The accumulated surveillance data including temporal, spatial, clinical, and demographic information, can provide valuable information with which to infer the underlying epidemic networks. Such networks can be quite informative and insightful as they characterize how infectious diseases transmit from one location to another. The aim of this work is to develop a computational model that allows inferences to be made regarding epidemic network topology in heterogeneous populations. We apply our model on the surveillance data from the 2009 H1N1 pandemic in Hong Kong. The inferred epidemic network displays significant effect on the propagation of infectious diseases.

  8. [Flaccid paralysis surveillance in the Latium Region].

    Science.gov (United States)

    Patti, A M; Santi, A L; Ciapetti, C; Fiore, L; Novello, F; Vellucci, L; De Stefano, F; Fara, G M

    2000-01-01

    The goal of World Health Organization is to reach the global eradication of poliomyelitis during the first decade of the third millennium. To achieve the certification of the eradication of the disease the main strategy is the Acute Flaccid Paralysis (AFP) surveillance. In Italy the active AFP surveillance was performed at national level since 1997. In the Latium region the active surveillance was performed since January 1997 by the laboratory of virology of Institute of Hygiene G Sanarelli which established a regional hospital network. During the years of survey 7 cases were found in 1997 (0.87/100,000), 4 in 1998 (0.5/100,000), 2 in 1999 (0.25/100,000) and 2 in 2000. No wild polioviruses were detected.

  9. Epidemiological Concepts Regarding Disease Monitoring and Surveillance

    Directory of Open Access Journals (Sweden)

    Christensen Jette

    2001-03-01

    Full Text Available Definitions of epidemiological concepts regarding disease monitoring and surveillance can be found in textbooks on veterinary epidemiology. This paper gives a review of how the concepts: monitoring, surveillance, and disease control strategies are defined. Monitoring and surveillance systems (MO&SS involve measurements of disease occurrence, and the design of the monitoring determines which types of disease occurrence measures can be applied. However, the knowledge of the performance of diagnostic tests (sensitivity and specificity is essential to estimate the true occurrence of the disease. The terms, disease control programme (DCP or disease eradication programme (DEP, are defined, and the steps of DCP/DEP are described to illustrate that they are a process rather than a static MO&SS.

  10. Enhancing Disease Surveillance Event Communication Among Jurisdictions.

    Science.gov (United States)

    Tabernero, Nathaniel R; Loschen, Wayne A; Jorgensen, Joel; Suereth, Joshua; Coberly, Jacqueline S; Holtry, Rekha S; Sikes, Marvin L; Babin, Steven M; Lewis, Sheryl L Happel

    2009-01-01

    Automated disease surveillance systems are becoming widely used by the public health community. However, communication among non-collocated and widely dispersed users still needs improvement. A web-based software tool for enhancing user communications was completely integrated into an existing automated disease surveillance system and was tested during two simulated exercises and operational use involving multiple jurisdictions. Evaluation of this tool was conducted by user meetings, anonymous surveys, and web logs. Public health officials found this tool to be useful, and the tool has been modified further to incorporate features suggested by user responses. Features of the automated disease surveillance system, such as alerts and time series plots, can be specifically referenced by user comments. The user may also indicate the alert response being considered by adding a color indicator to their comment. The web-based event communication tool described in this article provides a common ground for collaboration and communication among public health officials at different locations.

  11. [Recommendations for the surveillance of Aedes aegypti].

    Science.gov (United States)

    Barrera, Roberto

    2016-09-01

    Diseases caused by arboviruses transmitted by Aedes aegypti, such as dengue, chikungunya and Zika, continue to rise in annual incidence and geographic expansion. A key limitation for achieving control of A. aegypti has been the lack of effective tools for monitoring its population, and thus determine what control measures actually work. Surveillance of A. aegypti has been based mainly on immature indexes, but they bear little relation to the number of mosquito females, which are the ones capable of transmitting the viruses. The recent development of sampling techniques for adults of this vector species promises to facilitate surveillance and control activities. In this review, we present the various monitoring techniques for this mosquito, along with a discussion of their usefulness, and recommendations for improved entomological surveillance.

  12. MARGINAL EXPENSE OIL WELL WIRELESS SURVEILLANCE MEOWS

    Energy Technology Data Exchange (ETDEWEB)

    Mason M. Medizade; John R. Ridgely; Donald G. Nelson

    2004-11-01

    A marginal expense oil well wireless surveillance system to monitor system performance and production from rod-pumped wells in real time from wells operated by Vaquero Energy in the Edison Field, Main Area of Kern County in California has been successfully designed and field tested. The surveillance system includes a proprietary flow sensor, a programmable transmitting unit, a base receiver and receiving antenna, and a base station computer equipped with software to interpret the data. First, the system design is presented. Second, field data obtained from three wells is shown. Results of the study show that an effective, cost competitive, real-time wireless surveillance system can be introduced to oil fields across the United States and the world.

  13. Enhanced Video Surveillance (EVS) with speckle imaging

    Energy Technology Data Exchange (ETDEWEB)

    Carrano, C J

    2004-01-13

    Enhanced Video Surveillance (EVS) with Speckle Imaging is a high-resolution imaging system that substantially improves resolution and contrast in images acquired over long distances. This technology will increase image resolution up to an order of magnitude or greater for video surveillance systems. The system's hardware components are all commercially available and consist of a telescope or large-aperture lens assembly, a high-performance digital camera, and a personal computer. The system's software, developed at LLNL, extends standard speckle-image-processing methods (used in the astronomical community) to solve the atmospheric blurring problem associated with imaging over medium to long distances (hundreds of meters to tens of kilometers) through horizontal or slant-path turbulence. This novel imaging technology will not only enhance national security but also will benefit law enforcement, security contractors, and any private or public entity that uses video surveillance to protect their assets.

  14. Statistical analyses in disease surveillance systems.

    Science.gov (United States)

    Lescano, Andres G; Larasati, Ria Purwita; Sedyaningsih, Endang R; Bounlu, Khanthong; Araujo-Castillo, Roger V; Munayco-Escate, Cesar V; Soto, Giselle; Mundaca, C Cecilia; Blazes, David L

    2008-11-14

    The performance of disease surveillance systems is evaluated and monitored using a diverse set of statistical analyses throughout each stage of surveillance implementation. An overview of their main elements is presented, with a specific emphasis on syndromic surveillance directed to outbreak detection in resource-limited settings. Statistical analyses are proposed for three implementation stages: planning, early implementation, and consolidation. Data sources and collection procedures are described for each analysis.During the planning and pilot stages, we propose to estimate the average data collection, data entry and data distribution time. This information can be collected by surveillance systems themselves or through specially designed surveys. During the initial implementation stage, epidemiologists should study the completeness and timeliness of the reporting, and describe thoroughly the population surveyed and the epidemiology of the health events recorded. Additional data collection processes or external data streams are often necessary to assess reporting completeness and other indicators. Once data collection processes are operating in a timely and stable manner, analyses of surveillance data should expand to establish baseline rates and detect aberrations. External investigations can be used to evaluate whether abnormally increased case frequency corresponds to a true outbreak, and thereby establish the sensitivity and specificity of aberration detection algorithms.Statistical methods for disease surveillance have focused mainly on the performance of outbreak detection algorithms without sufficient attention to the data quality and representativeness, two factors that are especially important in developing countries. It is important to assess data quality at each state of implementation using a diverse mix of data sources and analytical methods. Careful, close monitoring of selected indicators is needed to evaluate whether systems are reaching their

  15. Disease surveillance using a hidden Markov model

    Directory of Open Access Journals (Sweden)

    Wright Graeme

    2009-08-01

    Full Text Available Abstract Background Routine surveillance of disease notification data can enable the early detection of localised disease outbreaks. Although hidden Markov models (HMMs have been recognised as an appropriate method to model disease surveillance data, they have been rarely applied in public health practice. We aimed to develop and evaluate a simple flexible HMM for disease surveillance which is suitable for use with sparse small area count data and requires little baseline data. Methods A Bayesian HMM was designed to monitor routinely collected notifiable disease data that are aggregated by residential postcode. Semi-synthetic data were used to evaluate the algorithm and compare outbreak detection performance with the established Early Aberration Reporting System (EARS algorithms and a negative binomial cusum. Results Algorithm performance varied according to the desired false alarm rate for surveillance. At false alarm rates around 0.05, the cusum-based algorithms provided the best overall outbreak detection performance, having similar sensitivity to the HMMs and a shorter average time to detection. At false alarm rates around 0.01, the HMM algorithms provided the best overall outbreak detection performance, having higher sensitivity than the cusum-based Methods and a generally shorter time to detection for larger outbreaks. Overall, the 14-day HMM had a significantly greater area under the receiver operator characteristic curve than the EARS C3 and 7-day negative binomial cusum algorithms. Conclusion Our findings suggest that the HMM provides an effective method for the surveillance of sparse small area notifiable disease data at low false alarm rates. Further investigations are required to evaluation algorithm performance across other diseases and surveillance contexts.

  16. Creating a global dialogue on infectious disease surveillance: connecting organizations for regional disease surveillance (CORDS).

    Science.gov (United States)

    Gresham, Louise S; Smolinski, Mark S; Suphanchaimat, Rapeepong; Kimball, Ann Marie; Wibulpolprasert, Suwit

    2013-01-01

    Connecting Organizations for Regional Disease Surveillance (CORDS) is an international non-governmental organization focused on information exchange between disease surveillance networks in different areas of the world. By linking regional disease surveillance networks, CORDS builds a trust-based social fabric of experts who share best practices, surveillance tools and strategies, training courses, and innovations. CORDS exemplifies the shifting patterns of international collaboration needed to prevent, detect, and counter all types of biological dangers - not just naturally occurring infectious diseases, but also terrorist threats. Representing a network-of-networks approach, the mission of CORDS is to link regional disease surveillance networks to improve global capacity to respond to infectious diseases. CORDS is an informal governance cooperative with six founding regional disease surveillance networks, with plans to expand; it works in complement and cooperatively with the World Health Organization (WHO), the World Organization for Animal Health (OIE), and the Food and Animal Organization of the United Nations (FAO). As described in detail elsewhere in this special issue of Emerging Health Threats, each regional network is an alliance of a small number of neighboring countries working across national borders to tackle emerging infectious diseases that require unified regional efforts. Here we describe the history, culture and commitment of CORDS; and the novel and necessary role that CORDS serves in the existing international infectious disease surveillance framework.

  17. Creating a Global Dialogue on Infectious Disease Surveillance: Connecting Organizations for Regional Disease Surveillance (CORDS

    Directory of Open Access Journals (Sweden)

    Louise S. Gresham

    2013-01-01

    Full Text Available Connecting Organizations for Regional Disease Surveillance (CORDS is an international non-governmental organization focused on information exchange between disease surveillance networks in different areas of the world. By linking regional disease surveillance networks, CORDS builds a trust-based social fabric of experts who share best practices, surveillance tools and strategies, training courses, and innovations. CORDS exemplifies the shifting patterns of international collaboration needed to prevent, detect, and counter all types of biological dangers – not just naturally occurring infectious diseases, but also terrorist threats. Representing a network-of-networks approach, the mission of CORDS is to link regional disease surveillance networks to improve global capacity to respond to infectious diseases. CORDS is an informal governance cooperative with six founding regional disease surveillance networks, with plans to expand; it works in complement and cooperatively with the World Health Organization (WHO, the World Organization for Animal Health (OIE, and the Food and Animal Organization of the United Nations (FAO. As described in detail elsewhere in this special issue of Emerging Health Threats, each regional network is an alliance of a small number of neighboring countries working across national borders to tackle emerging infectious diseases that require unified regional efforts. Here we describe the history, culture and commitment of CORDS; and the novel and necessary role that CORDS serves in the existing international infectious disease surveillance framework.

  18. Design of a Miniature Autonomous Surveillance Robot

    Institute of Scientific and Technical Information of China (English)

    ZHENG Chang-e; HUANG Qiang; HUANG Yuan-can

    2009-01-01

    The small size of miniature robots poses great challenges for the mechanical and deetrieal design and the implementation of autonomous capabilities.In this paper,the mechanical and electrical design for a twowheeled cylindrical miniature autonomous robot ("BMS-1",BIT MicroScout-1) is presented and some autonomous capabilities are implemented by multiple sensors and some arithmetic models.Several experimental results show that BMS-1 is useful for surveillance in confined spaces and suitable for large-scale surveillance due to some autonomous capabilities.

  19. Intelligent video surveillance systems and technology

    CERN Document Server

    Ma, Yunqian

    2009-01-01

    From the streets of London to subway stations in New York City, hundreds of thousands of surveillance cameras ubiquitously collect hundreds of thousands of videos, often running 24/7. How can such vast volumes of video data be stored, analyzed, indexed, and searched? How can advanced video analysis and systems autonomously recognize people and detect targeted activities real-time? Collating and presenting the latest information Intelligent Video Surveillance: Systems and Technology explores these issues, from fundamentals principle to algorithmic design and system implementation.An Integrated

  20. Event-driven surveillance possibilities and challenges

    CERN Document Server

    Denecke, Kerstin

    2012-01-01

    The Web has become a rich source of personal information in the last few years. People twitter, blog, and chat online. Current feelings, experiences or latest news are posted. For instance, first hints to disease outbreaks, customer preferences, or political changes could be identified with this data. Surveillance or early warning systems enable such detection of changes and support humans in getting information on changing situations. However, the variety of data that could be considered for surveillance is immense, ranging from sensor-measured values to collected counts and information extra