WorldWideScience

Sample records for surgically implanted newly

  1. Surgical stent for dental implant using cone beam CT images

    International Nuclear Information System (INIS)

    Choi, Hyung Soo; Kim, Gyu Tae; Choi, Yong Suk; Hwang, Eui Hwan

    2010-01-01

    The purpose of this study is to develop a surgical stent for dental implant procedure that can be easily applied and affordable by using cone beam computerized tomography (CBCT). Aluminum, Teflon-PFA (perfluoroalkoxy), and acetal (polyoxymethylene plastic) were selected as materials for the surgical stent. Among these three materials, the appropriate material was chosen using the CBCT images. The surgical stent, which could be easily placed into an oral cavity, was designed with chosen material. CBCT images of the new surgical stent on mandible were obtained using Alphard-3030 dental CT system (Asahi Roentgen Co., Ltd., Kyoto, Japan). The point of insertion was prescribed on the surgical stent with the multiplanar reconstruction software of OnDemand3D (CyberMed Inc., Seoul, Korea). Guide holes were made at the point of insertion on the surgical stent using newly designed guide jig. CBCT scans was taken for the second time to verify the accuracy of the newly designed surgical stent. Teflon-PFA showed radiologically excellent image characteristics for the surgical stent. High accuracy and reproducibility of implantation were confirmed with the surgical stent. The newly designed surgical stent can lead to the accurate implantation and achieve the clinically predictable result.

  2. Observation of the bone mineral density of newly formed bone using rabbits. Compared with newly formed bone around implants and cortical bone

    International Nuclear Information System (INIS)

    Nakada, Hiroshi; Numata, Yasuko; Sakae, Toshiro; Tamaki, Hiroyuki; Kato, Takao

    2009-01-01

    There have been many studies reporting that newly formed bone around implants is spongy bone. However, although the morphology is reported as being like spongy bone, it is difficult to discriminate whether the bone quality of newly formed bone appears similar to osteoid or cortical bone; therefore, evaluation of bone quality is required. The aims of this study were to measure the bone mineral density (BMD) values of newly formed bone around implants after 4, 8, 16, 24 and 48 weeks, to represent these values on three-dimensional color mapping (3Dmap), and to evaluate the change in bone quality associated with newly formed bone around implants. The animal experimental protocol of this study was approved by the Ethics Committee for Animal Experiments of our University. This experiment used 20 surface treatment implants (Ti-6Al-4V alloy: 3.1 mm in diameter and 30.0 mm in length) by grit-blasting. They were embedded into surgically created flaws in femurs of 20 New Zealand white rabbits (16 weeks old, male). The rabbits were sacrificed with an ear intravenous overdose of pentobarbital sodium under general anesthesia each period, and the femurs were resected. We measured BMD of newly formed bone around implants and cortical bone using Micro-CT, and the BMD distribution map of 3Dmap (TRI/3D Bon BMD, Ratoc System Engineering). The BMD of cortical bone was 1,026.3±44.3 mg/cm 3 at 4 weeks, 1,023.8±40.9 mg/cm 3 at 8 weeks, 1,048.2±45.6 mg/cm 3 at 16 weeks, 1,067.2±60.2 mg/cm 3 at 24 weeks, and 1,069.3±50.7 mg/cm 3 at 48 weeks after implantation, showing a non-significant increase each period. The BMD of newly formed bone around implants was 296.8±25.6 mg/cm 3 at 4 weeks, 525.0±72.4 mg/cm 3 at 8 weeks, 691.2±26.0 mg/cm 3 at 16 weeks, 776.9±27.7 mg/cm 3 at 24 weeks, and 845.2±23.1 mg/cm 3 at 48 weeks after implantation, showing a significant increase after each period. It was revealed that the color scale of newly formed bone was Low level at 4 weeks, and then it

  3. A Novel Surgical Template Design in Staged Dental Implant Rehabilitations

    Directory of Open Access Journals (Sweden)

    Michael Patras

    2012-05-01

    Full Text Available Background: The philosophy of a gradual transition to an implant retained prosthesis in cases of full-mouth or extensive rehabilitation usually involves a staged treatment concept. In this therapeutic approach, the placement of implants may sometimes be divided into phases. During a subsequent surgical phase of treatment, the pre-existing implants can serve as anchors for the surgical template. Those modified surgical templates help in the precise transferring of restorative information into the surgical field and guide the optimal three-dimensional implant positioning. Methods: This article highlights the rationale of implant-retained surgical templates and illustrates them through the presentation of two clinical cases. The templates are duplicates of the provisional restorations and are secured to the existing implants through the utilization of implant mounts. Results: This template design in such staged procedures provided stability in the surgical field and enhanced the accuracy in implant positioning based upon the planned restoration, thus ensuring predictable treatment outcomes.Conclusions: Successful rehabilitation lies in the correct sequence of surgical and prosthetic procedures. Whenever a staged approach of implant placement is planned, the clinician can effectively use the initially placed implants as anchors for the surgical template during the second phase of implant surgery.

  4. Accuracy of Implants Placed with Surgical Guides: Thermoplastic Versus 3D Printed.

    Science.gov (United States)

    Bell, Caitlyn K; Sahl, Erik F; Kim, Yoon Jeong; Rice, Dwight D

    This study was conducted to evaluate the accuracy of implants placed using two different guided implant surgery materials: thermoplastic versus three-dimensionally (3D) printed. A cone beam computed tomography (CBCT) scan previously obtained and selected for single-tooth implant replacement was converted into a Digital Imaging and Communications in Medicine (DICOM) file. All models were planned and exported for printing using BlueSkyBio Plan Software with the DICOM files. A total of 20 3D-printed mandibular quadrant jaws replicating the CBCT were printed by Right Choice Milling, as was the control model to accept the control implant. Previously, 10 thermoplastic and 10 3D-printed surgical guides had been made by the same lab technician at Right Choice Milling. One Nobel Biocare implant with a trilobe connection was placed per guide and replica jaw model pair. Implants were placed using the thermoplastic and 3D-printed surgical guides, representing the two test groups, following the Nobel Biocare guided surgical protocol. A total of 21 CBCT scans were then taken, one for the control implant and one for each test implant. The CBCT volume was converted to a DICOM file and transferred to Invivo5 software version 5.4 (Anatomage). The DICOM file of each test implant was superimposed over the DICOM file of the control. The deviation of the head of the implant, the deviation of the apex of the implant, and the angle of deviation were evaluated from measurements on the superimposition of the control and test implants. Mann-Whitney U test was used to test the null hypotheses at α = .05 and a confidence interval of 95%. Descriptive statistics were used for the average ± standard deviation. The implants placed with the thermoplastic surgical guides showed an average of 3.40 degrees of angular deviation compared to 2.36 degrees for implants placed with the 3D-printed surgical guides (P = .143). The implants placed with the thermoplastic surgical guides showed an average of 1

  5. Surgical templates for dental implant positioning; current knowledge and clinical perspectives

    Directory of Open Access Journals (Sweden)

    Mohammed Zaheer Kola

    2015-01-01

    Full Text Available Dental implants have been used in a variety of different forms for many years. Since the mid-20 th century, there has been an increase in interest in the implant process for the replacement of missing teeth. Branemark was one of the initial pioneers who applied scientifically based research techniques to develop an endosseous implant that forms an immobile connection with bone. The need for a dental implant to completely address multiple physical and biological factors imposes tremendous constraints on the surgical and handling protocol. Metallic dental implants have been successfully used for decades, but they have serious shortcomings related to their bony union and the fact that their mechanical properties do not match those of bone. However, anatomic limitation and restorative demands encourage the surgeon to gain precision in planning and surgical positioning of dental implants. Ideal placement of the implant facilitates the establishment of favorable forces on the implants and the prosthetic component as well as ensures an aesthetic outcome. Therefore, it is advisable to establish a logical continuity between the planned restoration and the surgical phases, it is essential to use a transfer device that for sure increases the predictability of success. The surgical guide template is fabricated by a dental technician after the presurgical restorative appointments that primarily include determination of occlusal scheme and implant angulations. Here, authors genuinely attempted to review the evolution and clinical applicability of surgical templates used in the placement of dental implants.

  6. Erythritol-Enriched Air-Polishing Powder for the Surgical Treatment of Peri-Implantitis

    Directory of Open Access Journals (Sweden)

    Silvio Taschieri

    2015-01-01

    Full Text Available Peri-implantitis represents a major complication that can compromise the success and survival of implant-supported rehabilitations. Both surgical and nonsurgical treatment protocols were proposed to improve clinical parameters and to treat implants affected by peri-implantitis. A systematic review of the literature was performed on electronic databases. The use of air-polishing powder in surgical treatment of peri-implantitis was investigated. A total of five articles, of different study designs, were included in the review. A meta-analysis could not be performed. The data from included studies reported a substantial benefit of the use of air-polishing powders for the decontamination of implant surface in surgical protocols. A case report of guided bone regeneration in sites with implants affected by peri-implantitis was presented. Surgical treatment of peri-implantitis, though demanding and not supported by a wide scientific literature, could be considered a viable treatment option if an adequate decontamination of infected surfaces could be obtained.

  7. Reliability of implant surgical guides based on soft-tissue models.

    Science.gov (United States)

    Maney, Pooja; Simmons, David E; Palaiologou, Archontia; Kee, Edwin

    2012-12-01

    The purpose of this study was to determine the accuracy of implant surgical guides fabricated on diagnostic casts. Guides were fabricated with radiopaque rods representing implant positions. Cone beam computerized tomograms were taken with guides in place. Accuracy was evaluated using software to simulate implant placement. Twenty-two sites (47%) were considered accurate (13 of 24 maxillary and 9 of 23 mandibular sites). Soft-tissue models do not always provide sufficient accuracy for fabricating implant surgical guides.

  8. Surgical implantation techniques for electronic tags in fish

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Glenn N.; Cooke, Steven J.; Brown, Richard S.; Deters, Katherine A.

    2011-01-01

    Intracoelomic implantation of transmitters into fish requires making a surgical incision, incision closure, and other surgery related techniques; however, the tools and techniques used in the surgical process vary widely. We review the available literature and focus on tools and techniques used for conducting surgery on juvenile salmonids because of the large amount of research that is conducted on them. The use of sterilized surgical instruments properly selected for a given size of fish will minimize tissue damage and infection rates, and speed the wound healing of fish implanted with transmitters. For the implantation of transmitters into small fish, the optimal surgical methods include making an incision on the ventral midline along the linea alba (for studies under 1 month), protecting the viscera (by lifting the skin with forceps while creating the incision), and using absorbable monofilament suture with a small-swaged-on swaged-on tapered or reverse-cutting needle. Standardizing the implantation techniques to be used in a study involving particular species and age classes of fish will improve survival and transmitter retention while allowing for comparisons to be made among studies and across multiple years. This review should be useful for researchers working on juvenile salmonids and other sizes and species of fish.

  9. Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants.

    Science.gov (United States)

    Ersoy, Ahmet Ersan; Turkyilmaz, Ilser; Ozan, Oguz; McGlumphy, Edwin A

    2008-08-01

    Dental implant placement requires precise planning with regard to anatomic limitations and restorative goals. The aim of this study was to evaluate the match between the positions and axes of the planned and placed implants using stereolithographic (SLA) surgical guides. Ninety-four implants were placed using SLA surgical guides generated from computed tomography (CT) between 2005 and 2006. Radiographic templates were used for all subjects during CT imaging. After obtaining three-dimensional CT images, each implant was virtually placed on the CT images. SLA surgical guides, fabricated using an SLA machine with a laser beam to polymerize the liquid photo-polymerized resin, were used during implant placement. A new CT scan was taken for each subject following implant placement. Special software was used to fuse the images of the planned and placed implants, and the locations and axes were compared. Compared to the planned implants, the placed implants showed angular deviation of 4.9 degrees+/-2.36 degrees, whereas the mean linear deviation was 1.22+/-0.85 mm at the implant neck and 1.51+/-1 mm at the implant apex. Compared to the implant planning, the angular deviation and linear deviation at the neck and apex of the placed maxillary implants were 5.31 degrees+/-0.36 degrees, 1.04+/-0.56 mm, and 1.57+/-0.97 mm, respectively, whereas corresponding figures for placed mandibular implants were 4.44 degrees+/-0.31 degrees, 1.42+/-1.05 mm, and 1.44+/-1.03 mm, respectively. SLA surgical guides using CT data may be reliable in implant placement and make flapless implant placement possible.

  10. Transcatheter aortic valve prosthesis surgically replaced 4 months after implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Lund, Jens Teglgaard; Engstrøm, Thomas

    2010-01-01

    Transcatheter aortic valve implantation is a new and rapidly evolving treatment option for high-risk surgical patients with degenerative aortic valve stenosis. Long-term results with these new valve prostheses are lacking, and potential valve dysfunction and failure would require valve replacemen....... We report the first case of surgical valve replacement in a patient with a dysfunctional transcatheter-implanted aortic valve prosthesis 4 months after implantation....

  11. Does the Implant Surgical Technique Affect the Primary and/or Secondary Stability of Dental Implants? A Systematic Review

    Science.gov (United States)

    Shadid, Rola Muhammed; Sadaqah, Nasrin Rushdi; Othman, Sahar Abdo

    2014-01-01

    Background. A number of surgical techniques for implant site preparation have been advocated to enhance the implant of primary and secondary stability. However, there is insufficient scientific evidence to support the association between the surgical technique and implant stability. Purpose. This review aimed to investigate the influence of different surgical techniques including the undersized drilling, the osteotome, the piezosurgery, the flapless procedure, and the bone stimulation by low-level laser therapy on the primary and/or secondary stability of dental implants. Materials and methods. A search of PubMed, Cochrane Library, and grey literature was performed. The inclusion criteria comprised observational clinical studies and randomized controlled trials (RCTs) conducted in patients who received dental implants for rehabilitation, studies that evaluated the association between the surgical technique and the implant primary and/or secondary stability. The articles selected were carefully read and classified as low, moderate, and high methodological quality and data of interest were tabulated. Results. Eight clinical studies were included then they were classified as moderate or high methodological quality and control of bias. Conclusions. There is a weak evidence suggesting that any of previously mentioned surgical techniques could influence the primary and/or secondary implant stability. PMID:25126094

  12. Does the Implant Surgical Technique Affect the Primary and/or Secondary Stability of Dental Implants? A Systematic Review

    Directory of Open Access Journals (Sweden)

    Rola Muhammed Shadid

    2014-01-01

    Full Text Available Background. A number of surgical techniques for implant site preparation have been advocated to enhance the implant of primary and secondary stability. However, there is insufficient scientific evidence to support the association between the surgical technique and implant stability. Purpose. This review aimed to investigate the influence of different surgical techniques including the undersized drilling, the osteotome, the piezosurgery, the flapless procedure, and the bone stimulation by low-level laser therapy on the primary and/or secondary stability of dental implants. Materials and methods. A search of PubMed, Cochrane Library, and grey literature was performed. The inclusion criteria comprised observational clinical studies and randomized controlled trials (RCTs conducted in patients who received dental implants for rehabilitation, studies that evaluated the association between the surgical technique and the implant primary and/or secondary stability. The articles selected were carefully read and classified as low, moderate, and high methodological quality and data of interest were tabulated. Results. Eight clinical studies were included then they were classified as moderate or high methodological quality and control of bias. Conclusions. There is a weak evidence suggesting that any of previously mentioned surgical techniques could influence the primary and/or secondary implant stability.

  13. Infective endocarditis following Melody valve implantation: comparison with a surgical cohort.

    Science.gov (United States)

    O'Donnell, Clare; Holloway, Rhonda; Tilton, Elizabeth; Stirling, John; Finucane, Kirsten; Wilson, Nigel

    2017-03-01

    Infective endocarditis has been reported post Melody percutaneous pulmonary valve implant; the incidence and risk factors, however, remain poorly defined. We identified four cases of endocarditis from our first 25 Melody implants. Our aim was to examine these cases in the context of postulated risk factors and directly compare endocarditis rates with local surgical valves. We conducted a retrospective review of patients post Melody percutaneous pulmonary valve implant in New Zealand (October, 2009-May, 2015) and also reviewed the incidence of endocarditis in New Zealand among patients who have undergone surgical pulmonary valve implants. In total, 25 patients underwent Melody implantation at a median age of 18 years. At a median follow-up of 2.9 years, most were well with low valve gradient (median 27 mmHg) and only mild regurgitation. Two patients presented with life-threatening endocarditis and obstructive vegetations at 14 and 26 months post implant, respectively. Two additional patients presented with subacute endocarditis at 5.5 years post implant. From 2009 to May, 2015, 178 surgical pulmonic bioprostheses, largely Hancock valves and homografts, were used at our institution. At a median follow-up of 2.9 years, four patients (2%) had developed endocarditis in this group compared with 4/25 (16%) in the Melody group (p=0.0089). Three surgical valves have been replaced. The Melody valve offers a good alternative to surgical conduit replacement in selected patients. Many patients have excellent outcomes in the medium term. Endocarditis, however, can occur and if associated with obstruction can be life threatening. The risk for endocarditis in the Melody group was higher in comparison with that in a contemporaneous surgical pulmonary implant cohort.

  14. Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates.

    Science.gov (United States)

    Nickenig, Hans-Joachim; Eitner, Stephan

    2007-01-01

    We assessed the reliability of implant placement after virtual planning of implant positions using cone-beam CT data and surgical guide templates. A total of 102 patients (250 implants, 55.4% mandibular; mean patient age, 40.4 years) who had undergone implant treatment therapy in an armed forces dental clinic (Cologne, Germany) between July 1, 2005 and December 1, 2005. They were treated with a system that allows transfer of virtual planning to surgical guide templates. Only in eight cases the surgical guides were not used because a delayed implant placement was necessary. In four posterior mandibular cases, handling was limited because of reduced interocclusal distance, requiring 50% shortening of the drill guides. The predictability of implant size was high: only one implant was changed to a smaller diameter (because of insufficient bone). In all cases, critical anatomical structures were protected and no complications were detected in postoperative panoramic radiographs. In 58.1% (147) of the 250 implants, a flapless surgery plan was realized. Implant placement after virtual planning of implant positions using cone beam CT data and surgical templates can be reliable for preoperative assessment of implant size, position, and anatomical complications. It is also indicative of cases amenable to flapless surgery.

  15. Reliability of a CAD/CAM Surgical Guide for Implant Placement: An In Vitro Comparison of Surgeons' Experience Levels and Implant Sites.

    Science.gov (United States)

    Park, Su-Jung; Leesungbok, Richard; Cui, Taixing; Lee, Suk Won; Ahn, Su-Jin

    This in vitro study evaluated the reliability of a surgical guide with regard to different levels of operator surgical experience and implant site. A stereolithographic surgical guide for epoxy resin mandibles with three edentulous molar sites was produced using a computer-aided design/computer-assisted manufacture (CAD/CAM) system. Two surgeons with and two surgeons without implant surgery experience placed implants in a model either using or not using the CAD/CAM surgical guide. Four groups were created: inexperienced surgeon without the guide (group 1); experienced surgeon without the guide (group 2); inexperienced surgeon with the guide (group 3); and experienced surgeon with the guide (group 4). Planned implants and placed implants were superimposed using digital software, and deviation parameters were calculated. There were no significant differences in any of the deviation parameters between the groups when using the surgical guide. With respect to the implant sites, there were no significant differences among the groups in any parameter. Use of the CAD/CAM surgical guide reduced discrepancies among operators performing implant surgery regardless of their level of experience. Whether or not the guide was used, differences in the anterior-posterior implant site in the molar area did not affect the accuracy of implant placement.

  16. Comparison of two approaches to the surgical management of cochlear implantation

    NARCIS (Netherlands)

    Postelmans, Job T. F.; Grolman, Wilko; Tange, Rinze A.; Stokroos, Robert J.

    2009-01-01

    OBJECTIVES/HYPOTHESIS: Our study was designed to compare two surgical approaches that are currently employed in cochlear implantation. METHODS: There were 315 patients who were divided into two groups according to the surgical technique used for implantation. The suprameatal approach (SMA) was

  17. Biomedical engineering principles of modern cochlear implants and recent surgical innovations.

    Science.gov (United States)

    Eshraghi, Adrien A; Gupta, Chhavi; Ozdamar, Ozcan; Balkany, Thomas J; Truy, Eric; Nazarian, Ronen

    2012-11-01

    This review covers the most recent clinical and surgical advances made in the development and application of cochlear implants (CIs). In recent years, dramatic progress has been made in both clinical and basic science aspect of cochlear implantation. Today's modern CI uses multi-channel electrodes with highly miniaturized powerful digital processing chips. This review article describes the function of various components of the modern multi-channel CIs. A selection of the most recent clinical and surgical innovations is presented. This includes the preliminary results with electro-acoustic stimulation or hybrid devices and ongoing basic science research that is focused on the preservation of residual hearing post-implantation. The result of an original device that uses a binaural stimulation mode with a single implanted receiver/stimulator is also presented. The benefit and surgical design of a temporalis pocket technique for the implant's receiver stimulator is discussed. Advances in biomedical engineering and surgical innovations that lead to an increasingly favorable clinical outcome and to an expansion of the indication of CI surgery are presented and discussed. Copyright © 2012 Wiley Periodicals, Inc.

  18. Evaluation of primary and secondary stability of titanium implants using different surgical techniques.

    Science.gov (United States)

    Tabassum, Afsheen; Meijer, Gert J; Walboomers, X Frank; Jansen, John A

    2014-04-01

    To investigate the influence of different surgical techniques on the primary and secondary implant stability using trabecular bone of goats as an implantation model. In the iliac crest of eight goats, 48 cylindrical-screw-type implants with a diameter of 4.2 mm (Dyna(®) ; Bergen op Zoom, the Netherlands) were installed, using three different surgical techniques: (i) 5% undersized, using a final drill diameter of 4 mm; (ii) 15% undersized, using a final drill diameter of 3.6 mm; and (iii) 25% undersized, using a final drill diameter of 3.2 mm. Peak insertion torque values were measured by a Digital(®) (MARK-10 Corporation, New York, NY, USA) torque gauge instrument during placement. At 3 weeks after implantation, removal torque was measured. Histomorphometrically, the peri-implant bone volume was measured in three zones; the inner zone (0-500 μm), the middle zone (500-1000 μm) and the outer zone (1000-1500 μm). Evaluation of the obtained data demonstrated no statistically significant difference between different surgical techniques regarding removal torque values. With respect to the percentage peri-implant bone volume (%BV), also no significant difference could be observed between all three applied surgical techniques for both the inner, middle and outer zone. However, irrespective of the surgical technique, it was noticed that the %BV was significantly higher for the inner zone as compared to middle and outer zone (P < 0.05) around the implant. At 3 weeks after implant installation, independent of the used undersized surgical technique, the %BV in the inner zone (0-500 μm) peri-implant area was improved due to both condensation of the surrounding bone as also the translocation of host bone particles along the implant surface. Surprisingly, no mechanical beneficial effect of the 25% undersized surgical technique could be observed as compared to the 5% or 15% undersized surgical technique to improve primary or secondary implant stability. © 2013

  19. Ahmed glaucoma valve implant: surgical technique and complications.

    Science.gov (United States)

    Riva, Ivano; Roberti, Gloria; Oddone, Francesco; Konstas, Anastasios Gp; Quaranta, Luciano

    2017-01-01

    Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications.

  20. Maxillary Three-Implant Overdentures Opposing Mandibular Two-Implant Overdentures: 10-Year Surgical Outcomes of a Randomized Controlled Trial.

    Science.gov (United States)

    Ma, Sunyoung; Tawse-Smith, Andrew; De Silva, Rohana K; Atieh, Momen A; Alsabeeha, Nabeel H M; Payne, Alan G T

    2016-06-01

    The surgical placement of four maxillary implants for overdentures may not be obligatory when opposing mandibular two-implant overdentures. To determine 10-year surgical outcomes and implant success of three narrow diameter implants in edentulous maxillae with conventional loading. Forty participants with mandibular two-implant overdentures were randomly allocated for surgery for maxillary overdentures. Using osteotomes, three implants of similar systems were placed with a one-stage procedure and 12-week loading with splinted and unsplinted prosthodontic designs. Marginal bone and stability measurements were done at surgery, 12 weeks, 1-, 2-, 5-, 7-, 10 years. One hundred seventeen implants were placed in 39 participants, with 35 being seen at 1 year; 29 at 2 years; 28 at 5 years; 26 at 7 years; and 23 (59%) at 10 years. Marginal bone loss was 1.35 mm between surgery and 12 weeks; 0.36 mm between 12 weeks and 1 year; 0.48 mm between 1 and 5 years; and 0.22 mm between 5 and 10 years. Implant stability quotients were 56.05, 57.54, 60.88, 58.80, 61.17 at surgery, 12 weeks, 1 year, 5 years, and 10 years. Four-field tables by implant showed success rates of 82% at 1 year; 69.2% at 2 years; 66.7% at 5 years; 61.5% at 7 years; 51.3% at 10 years. Data showed no differences between surgical technique, systems, or prosthodontic designs. Surgical placement with osteotomes of three narrow diameter implants for maxillary overdentures, opposing mandibular two-implant overdentures, is an acceptable approach, subject to strict patient selection. Implant success is independent of prosthodontic design. © 2015 Wiley Periodicals, Inc.

  1. Surgical Outcomes of Additional Ahmed Glaucoma Valve Implantation in Refractory Glaucoma.

    Science.gov (United States)

    Ko, Sung Ju; Hwang, Young Hoon; Ahn, Sang Il; Kim, Hwang Ki

    2016-06-01

    To evaluate the surgical outcomes of the implantation of an additional Ahmed glaucoma valve (AGV) into the eyes of patients with refractory glaucoma following previous AGV implantation. This study is a retrospective review of the clinical histories of 23 patients who had undergone a second AGV implantation after a failed initial implantation. Age, sex, prior surgery, glaucoma type, number of medications, intraocular pressure (IOP), visual acuity, and surgical complications were analyzed. Surgical success was defined as IOP maintained below 21 mm Hg, with at least a 20% overall reduction in IOP, regardless of the use of IOP-lowering medications. Following the implantation of a second AGV, the mean IOP decreased from 39.3 to 18.5 mm Hg (52.9% reduction, P<0.001). The mean number of postoperative IOP-lowering medications administered decreased from 2.8 to 1.7 after the second AGV implantation (P<0.001). The cumulative probability of success for the procedure was 87% after 1 year and 52% after 3 years. Three patients (13.0%) experienced bullous keratopathy after the second AGV implantation. None of the patients showed any evidence of diplopia or ocular movement limitation as a result of the presence of 2 AGVs in the same eye. Prior trabeculectomy was found to be a significant risk factor for failure (P=0.027). A second AGV implantation can be a good choice of surgical treatment when the first AGV has failed to control IOP.

  2. The effects of implant surface roughness and surgical technique on implant fixation in an in vitro model.

    NARCIS (Netherlands)

    Shalabi, M.M.; Wolke, J.G.C.; Jansen, J.A.

    2006-01-01

    OBJECTIVES: The aim of the present study was to determine the relationship between implant surface parameters, surgical approach and initial implant fixation. MATERIAL AND METHODS: Sixty tapered, conical, screw-shaped implants with machined or etched surface topography were implanted into the

  3. Ahmed glaucoma valve implant: surgical technique and complications

    Directory of Open Access Journals (Sweden)

    Riva I

    2017-02-01

    Full Text Available Ivano Riva,1 Gloria Roberti,1 Francesco Oddone,1 Anastasios GP Konstas,2 Luciano Quaranta3 1IRCCS “Fondazione GB Bietti per l’Oftalmologia”, Rome, Italy; 21st University Department of Ophthalmology, Glaucoma Unit, AHEPA Hospital, Thessaloniki, Greece; 3Department of Medical and Surgical Specialties, Section of Ophthalmology, University of Brescia, Brescia, Italy Abstract: Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications. Keywords: glaucoma, surgical technique, glaucoma drainage devices, Ahmed glaucoma valve, complications

  4. Hemiepiphysiodesis Implants for Late-onset Tibia Vara: A Comparison of Cost, Surgical Success, and Implant Failure.

    Science.gov (United States)

    Funk, Shawn S; Mignemi, Megan E; Schoenecker, Jonathan G; Lovejoy, Steven A; Mencio, Gregory A; Martus, Jeffrey E

    2016-01-01

    The purpose of this study was to compare hemiepiphysiodesis implants for late-onset tibia vara and to evaluate patient characteristics that may predict surgical failure. This is a retrospective review of late-onset tibia vara patients treated with temporary hemiepiphysiodesis from 1998 to 2012. Mechanical axis deviation (MAD), mechanical axis angle, mechanical lateral distal femoral angle, and medial proximal tibial angle were measured on standing bone length radiographs. Surgical failure was defined as residual deformity requiring osteotomy, revision surgery, or MAD exceeding 40 mm at the time of final follow-up. Implant failure was recorded. Costs included implants and disposables required for construct placement. Staple constructs included 2 or 3 staples. Plate constructs included the plate, screws, guide wires, and drill bits. A total of 25 patients with 38 temporary lateral proximal tibia hemiepiphysiodeses met the inclusion criteria. The average body mass index (BMI) was 39.1 kg/m with an average follow-up of 3.0 years (minimum 1 y). Surgical failure occurred in 57.9% of patients. Greater BMI (P=0.05) and more severe deformity (MAD, mechanical axis angle, and medial proximal tibial angle; Pfailure. Younger age predicted higher rates of implant failure (Pfailure between staple and plate systems. Hospital costs of plate constructs ($781 to $1244) were 1.5 to 3.5 times greater than the staple constructs ($332 to $498). Greater BMI, more severe deformity, and younger age were predictive of surgical or implant failure. There was no difference in success between implant types, whereas the cost of plate constructs was 1.5 to 3.5 times greater than staples. The rate of surgical failure was high (58%) and consideration should be given to reserving hemiepiphysiodesis for patients with lower BMI and less severe deformity. In our population, if hemiepiphysiodesis was not offered to patients with BMI>35 or MAD>80 mm varus, the surgical failure rate would diminish to 28

  5. Surgical Non-Regenerative Treatments for Peri-Implantitis: a Systematic Review

    Directory of Open Access Journals (Sweden)

    Ausra Ramanauskaite

    2016-09-01

    Full Text Available Objectives: The purposes of the present study were 1 to systematically review the literature on the surgical non-regenerative treatments of peri-implantitis and 2 to determine a predictable therapeutic option for the clinical management of peri-implantitis lesions. Material and Methods: The study search was performed on primary database MEDLINE and EMBASE from 2005 until 2016. Sequential screenings at the title, abstract, and full-text levels were performed. Clinical human studies in the English language that had reported changes in probing depth (PD and/or bleeding on probing (BOP and/or radiologic marginal bone level changes after peri-implantitis surgical non-regenerative treatment at 6-month follow-up or longer were included accordingly PRISMA guidelines. Results: The first electronic and hand search resulted in 765 citations. From 16 full-text articles reviewed, 6 were included in this systematic review. Surgical non-regenerative methods were found to be efficient in reducing clinical parameters. BOP and PD values were significantly decreased following implantoplasty and systematic administration of antibacterials, but not after local application of chemical compounds or diode laser. Similarly, significant improvement in clinical and radiographic parameters was found only after implantoplasty compared with resective surgery alone. We found significant heterogeneity in study designs and treatments provided among the pooled studies. All of the studies revealed an unclear or high risk of bias. Conclusions: Surgical non-regenerative treatment of peri-implantitis was found to be effective to reduce the soft tissue inflammation and decrease probing depth. More randomized controlled clinical trials are needed to assess the efficacy of surgical non-regenerative therapy of peri-implantitis.

  6. Global convergence on the bioethics of surgical implants.

    Science.gov (United States)

    Garcia, Alberto; Monlezun, Dominique J

    2015-01-01

    The increasing globalization of mankind with pluralistic belief systems necessitates physicians by virtue of their profession to partner with bioethics for soundly applying emerging knowledge and technologies for the best use of the patient. A subfield within medicine in which this need is acutely felt is that of surgical implants. Within this subfield such recent promising ethics and medicine partnerships include the International Tissue Engineering Research Association and UNESCO Chair in Bioethics and Human Rights' International Code of Ethics. In this paper, we provide an overview of the emerging human rights framework from bioethics and international law, discussion of key framework principles, their application to the current surgical challenge of implantation of surgical mesh for prolapse, and conclusions and recommendations. Such discussions are meant to facilitate true quality improvement in patient care by ensuring the exciting technologies and medical practices emerging new daily are accompanied by an equal commitment of physicians to ethically provide their services for the chief end of the patient's good.

  7. Global Convergence on the Bioethics of Surgical Implants

    Science.gov (United States)

    Monlezun, Dominique J.

    2015-01-01

    The increasing globalization of mankind with pluralistic belief systems necessitates physicians by virtue of their profession to partner with bioethics for soundly applying emerging knowledge and technologies for the best use of the patient. A subfield within medicine in which this need is acutely felt is that of surgical implants. Within this subfield such recent promising ethics and medicine partnerships include the International Tissue Engineering Research Association and UNESCO Chair in Bioethics and Human Rights' International Code of Ethics. In this paper, we provide an overview of the emerging human rights framework from bioethics and international law, discussion of key framework principles, their application to the current surgical challenge of implantation of surgical mesh for prolapse, and conclusions and recommendations. Such discussions are meant to facilitate true quality improvement in patient care by ensuring the exciting technologies and medical practices emerging new daily are accompanied by an equal commitment of physicians to ethically provide their services for the chief end of the patient's good. PMID:25973426

  8. Surgical pitfalls with custom-made porous hydroxyapatite cranial implants

    Directory of Open Access Journals (Sweden)

    Bruno Zanotti

    2015-03-01

    Full Text Available Aim: Cranioplasty implants are used primarily in cases of surgical cranial decompression following pathological elevations of intracranial pressure. Available bone substitutes include porous hydroxyapatite (HA and polymethylmethacrylate. Whichever material is used, however, prosthetic cranial implants are susceptible to intra- and postsurgical complications and even failure. The aim of this study was to investigate such occurrences in HA cranioplasty implants, seeking not only to determine the likely causes (whether correlated or not with the device itself but also, where possible, to suggest countermeasures. Methods: We analyzed information regarding failures or complications reported in postmarketing surveillance and clinical studies of patients treated worldwide with custom-made HA cranial implants (Custom Bone Service Fin-Ceramica Faenza, Italy in the period 1997-2013. Results: The two most common complications were implant fractures (84 cases, 2.9% of the total fitted and infections (51 cases, 1.77%. Conclusion: Although cranioplasties are superficial and not difficult types of surgery, and use of custom-made implants are often considered the "easy" option from a surgical perspective, these procedures are nonetheless plagued by potential pitfalls. If performed well they yield more than satisfactory results from the points of view of both the patient and surgeon, but lack of appropriate care can open the door to numerous potential sources of failure, which can compromise-even irreparably-the ability to heal.

  9. [Retrieval and failure analysis of surgical implants in Brazil: the need for proper regulation].

    Science.gov (United States)

    Azevedo, Cesar R de Farias; Hippert, Eduardo

    2002-01-01

    This paper summarizes several cases of metallurgical failure analysis of surgical implants conducted at the Laboratory of Failure Analysis, Instituto de Pesquisas Tecnológicas (IPT), in Brazil. Failures with two stainless steel femoral compression plates, one stainless steel femoral nail plate, one Ti-6Al-4V alloy maxillary reconstruction plate, and five Nitinol wires were investigated. The results showed that the implants were not in accordance with ISO standards and presented evidence of corrosion-assisted fracture. Furthermore, some of the implants presented manufacturing/processing defects which also contributed to their premature failure. Implantation of materials that are not biocompatible may cause several types of adverse effects in the human body and lead to premature implant failure. A review of prevailing health legislation is needed in Brazil, along with the adoption of regulatory mechanisms to assure the quality of surgical implants on the market, providing for compulsory procedures in the reporting and investigation of surgical implants which have failed in service.

  10. Accurate pre-surgical determination for self-drilling miniscrew implant placement using surgical guides and cone-beam computed tomography.

    Science.gov (United States)

    Miyazawa, Ken; Kawaguchi, Misuzu; Tabuchi, Masako; Goto, Shigemi

    2010-12-01

    Miniscrew implants have proven to be effective in providing absolute orthodontic anchorage. However, as self-drilling miniscrew implants have become more popular, a problem has emerged, i.e. root contact, which can lead to perforation and other root injuries. To avoid possible root damage, a surgical guide was fabricated and cone-beam computed tomography (CBCT) was used to incorporate guide tubes drilled in accordance with the planned direction of the implants. Eighteen patients (5 males and 13 females; mean age 23.8 years; minimum 10.7, maximum 45.5) were included in the study. Forty-four self-drilling miniscrew implants (diameter 1.6, and length 8 mm) were placed in interradicular bone using a surgical guide procedure, the majority in the maxillary molar area. To determine the success rates, statistical analysis was undertaken using Fisher's exact probability test. CBCT images of post-surgical self-drilling miniscrew implant placement showed no root contact (0/44). However, based on CBCT evaluation, it was necessary to change the location or angle of 52.3 per cent (23/44) of the guide tubes prior to surgery in order to obtain optimal placement. If orthodontic force could be applied to the screw until completion of orthodontic treatment, screw anchorage was recorded as successful. The total success rate of all miniscrews was 90.9 per cent (40/44). Orthodontic self-drilling miniscrew implants must be inserted carefully, particularly in the case of blind placement, since even guide tubes made on casts frequently require repositioning to avoid the roots of the teeth. The use of surgical guides, fabricated using CBCT images, appears to be a promising technique for placement of orthodontic self-drilling miniscrew implants adjacent to the dental roots and maxillary sinuses.

  11. Study of breast implant rupture: MRI versus surgical findings.

    Science.gov (United States)

    Vestito, A; Mangieri, F F; Ancona, A; Minervini, C; Perchinunno, V; Rinaldi, S

    2012-09-01

    This study evaluated the role of breast magnetic resonance (MR) imaging in the selective study breast implant integrity. We retrospectively analysed the signs of breast implant rupture observed at breast MR examinations of 157 implants and determined the sensitivity and specificity of the technique in diagnosing implant rupture by comparing MR data with findings at surgical explantation. The linguine and the salad-oil signs were statistically the most significant signs for diagnosing intracapsular rupture; the presence of siliconomas/seromas outside the capsule and/or in the axillary lymph nodes calls for immediate explantation. In agreement with previous reports, we found a close correlation between imaging signs and findings at explantation. Breast MR imaging can be considered the gold standard in the study of breast implants.

  12. Reliability of computer designed surgical guides in six implant rehabilitations with two years follow-up.

    Science.gov (United States)

    Giordano, Mauro; Ausiello, Pietro; Martorelli, Massimo; Sorrentino, Roberto

    2012-09-01

    To evaluate the reliability and accuracy of computer-designed surgical guides in osseointegrated oral implant rehabilitation. Six implant rehabilitations, with a total of 17 implants, were completed with computer-designed surgical guides, performed with the master model developed by muco-compressive and muco-static impressions. In the first case, the surgical guide had exclusively mucosal support, in the second case exclusively dental support. For all six cases computer-aided surgical planning was performed by virtual analyses with 3D models obtained by dental scan DICOM data. The accuracy and stability of implant osseointegration over two years post surgery was then evaluated with clinical and radiographic examinations. Radiographic examination, performed with digital acquisitions (RVG - Radio Video graph) and parallel techniques, allowed two-dimensional feedback with a margin of linear error of 10%. Implant osseointegration was recorded for all the examined rehabilitations. During the clinical and radiographic post-surgical assessments, over the following two years, the peri-implant bone level was found to be stable and without appearance of any complications. The margin of error recorded between pre-operative positions assigned by virtual analysis and the post-surgical digital radiographic observations was as low as 0.2mm. Computer-guided implant surgery can be very effective in oral rehabilitations, providing an opportunity for the surgeon: (a) to avoid the necessity of muco-periosteal detachments and then (b) to perform minimally invasive interventions, whenever appropriate, with a flapless approach. Copyright © 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  13. Rehabilitation with 4 zygomatic implants with a new surgical protocol using ultrasonic technique.

    Science.gov (United States)

    Mozzati, Marco; Mortellaro, Carmen; Arata, Valentina; Gallesio, Giorgia; Previgliano, Valter

    2015-05-01

    When the residual bone crest cannot allow the placement of standard implants, the treatment for complete arch rehabilitation of severely atrophic maxillae can be performed with 4 zygomatic implants (ZIs) and immediate function with predictable results in terms of aesthetics, function, and comfort for the patient. However, even if ZIs' rehabilitations showed a good success rate, this surgery is difficult and need a skillful operator. Complications in this kind of rehabilitation are not uncommon; the main difficulties can be related to the reduced surgical visibility and instrument control in a critical anatomic area. All the surgical protocols described in the literature used drilling techniques. Furthermore, the use of ultrasonic instruments in implant surgery compared with drilling instruments have shown advantages in many aspects of surgical procedures, tissues management, enhancement of control, surgical visualization, and healing. The aim of this study was to report on the preliminary experience using ultrasound technique for ZIs surgery in terms of safety and technical improvement. Ten consecutive patients with severely atrophic maxilla have been treated with 4 ZIs and immediate complete arch acrylic resin provisional prostheses. The patients were followed up from 30 to 32 months evaluating implant success, prosthetic success, and patient satisfaction with a questionnaire. No implants were lost during the study period, with a 100% implant and prosthetic success rate. Within the limitations of this preliminary study, these data indicate that ultrasonic implant site preparation for ZIs can be a good alternative to the drilling technique and an improvement for the surgeon.

  14. Soft Tissue Surgical Procedures for Optimizing Anterior Implant Esthetics

    Science.gov (United States)

    Ioannou, Andreas L.; Kotsakis, Georgios A.; McHale, Michelle G.; Lareau, Donald E.; Hinrichs, James E.; Romanos, Georgios E.

    2015-01-01

    Implant dentistry has been established as a predictable treatment with excellent clinical success to replace missing or nonrestorable teeth. A successful esthetic implant reconstruction is predicated on two fundamental components: the reproduction of the natural tooth characteristics on the implant crown and the establishment of soft tissue housing that will simulate a healthy periodontium. In order for an implant to optimally rehabilitate esthetics, the peri-implant soft tissues must be preserved and/or augmented by means of periodontal surgical procedures. Clinicians who practice implant dentistry should strive to achieve an esthetically successful outcome beyond just osseointegration. Knowledge of a variety of available techniques and proper treatment planning enables the clinician to meet the ever-increasing esthetic demands as requested by patients. The purpose of this paper is to enhance the implant surgeon's rationale and techniques beyond that of simply placing a functional restoration in an edentulous site to a level whereby an implant-supported restoration is placed in reconstructed soft tissue, so the site is indiscernible from a natural tooth. PMID:26124837

  15. Surgical Results and Complications of Cochlear Implantation in Far-Advanced Otosclerosis

    DEFF Research Database (Denmark)

    West, Niels; Brand, Markus; Foghsgaard, Søren

    2017-01-01

    OBJECTIVE: To report surgical results and complications of cochlear implantation in patients with far-advanced otosclerosis (FAO). MATERIALS AND METHODS: This was a retrospective chart review of surgical results in terms of electrode insertion as well as peri- and postoperative complications. Ten...

  16. Magnetic resonance imaging metallic artifact of commonly encountered surgical implants and foreign material.

    Science.gov (United States)

    Sutherland-Smith, James; Tilley, Brenda

    2012-01-01

    Magnetic resonance imaging (MRI) artifacts secondary to metallic implants and foreign bodies are well described. Herein, we provide quantitative data from veterinary implants including total hip arthroplasty implants, cranial cruciate repair implants, surgical screws, a skin staple, ligation clips, an identification microchip, ameroid constrictor, and potential foreign bodies including air gun and BB projectiles and a sewing needle. The objects were scanned in a gelatin phantom with plastic grid using standardized T2-weighted turbo-spin echo (TSE), T1-weighted spin echo, and T2*-weighted gradient recalled echo (GRE) image acquisitions at 1.5 T. Maximum linear dimensions and areas of signal voiding and grid distortion were calculated using a DICOM workstation for each sequence and object. Artifact severity was similar between the T2-weighted TSE and T1-weighted images, while the T2*-weighted images were most susceptible to artifact. Metal type influenced artifact size with the largest artifacts arising from steel objects followed by surgical stainless steel, titanium, and lead. For animals with metallic surgical implants or foreign bodies, the quantification of the artifact size will help guide clinicians on the viability of MRI. © 2012 Veterinary Radiology & Ultrasound.

  17. Evaluation of primary and secondary stability of titanium implants using different surgical techniques

    NARCIS (Netherlands)

    Tabassum, A.; Meijer, G.J.; Walboomers, X.F.; Jansen, J.A.

    2014-01-01

    OBJECTIVE: To investigate the influence of different surgical techniques on the primary and secondary implant stability using trabecular bone of goats as an implantation model. MATERIAL AND METHODS: In the iliac crest of eight goats, 48 cylindrical-screw-type implants with a diameter of 4.2 mm

  18. Patients' perceptions of implant placement surgery, the post-surgical healing and the transitional implant prostheses: a qualitative study.

    Science.gov (United States)

    Kashbour, Wafa A; Rousseau, Nikki; Thomason, J Mark; Ellis, Janice S

    2017-07-01

    This study aimed to explore patients' thoughts, feelings about, and experiences of, implant placement surgery (IPS), the post-surgical healing stage and the immediate post-surgical transitional implant prosthesis (TIP) (fixed and removable). A qualitative study design was chosen and 38 semi-structured telephone and face-to-face interviews were conducted with 34 patients at different stages of implant treatment. The interviews were transcribed verbatim; the data collection and coding process followed the principles of thematic analysis, which was facilitated through the use of NVivo10. Patients anticipated that surgery would be painful and unpleasant but were prepared to accept this temporary discomfort for the expected benefits of implant treatment. However, a key finding was that patients felt they had overestimated the trauma of surgery but underestimated the discomfort and difficulties of the healing phase. A number of difficulties were also identified with the TIP phase following implant surgery. Existing research has tended to focus on the longer term benefits of dental implant treatment. This qualitative study has investigated in-depth patients' perceptions of dental implant surgery, including their experiences related to sedation, and of transitional implant restoration. While patients felt their concerns were overestimated in relation to the implant surgery, they experienced greater morbidity than they expected in the healing phase. Recommendations are made for relatively small changes in care provision which might improve the overall patient experience. Partial dentate patients treated with a fixed transitional prosthesis experienced advantages more quickly than patients with an overdenture. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Surgical management of fibrotic encapsulation of the fluocinolone acetonide implant in CAPN5-associated proliferative vitreoretinopathy.

    Science.gov (United States)

    Tlucek, Paul S; Folk, James C; Sobol, Warren M; Mahajan, Vinit B

    2013-01-01

    To review fibrosis of fluocinolone acetonide (FA) implants in subjects with CAPN5 autosomal dominant neovascular inflammatory vitreoretinopathy (ADNIV). A retrospective case series was assembled from ADNIV patients in which there was fibrotic encapsulation of a fluocinolone acetonide implant. CAPN5 genotypes and surgical repair techniques were reviewed. Two eyes of two ADNIV patients developed a fibrotic capsule over the fluocinolone acetonide implant. Both patients had Stage IV disease. Patient A had a c.731T > C mutation in the CAPN5 gene and patient B had a c.728G > T mutation. The fibrotic membrane was surgically excised and the implant function was restored. The exuberant fibrotic response in later stages of ADNIV may be resistant to local immunosuppression with steroids. Surgical excision of fibrotic membranes over FA implants can reestablish local steroid delivery in cases of severe proliferative vitreoretinopathy.

  20. Accuracy Assessment of Immediate and Delayed Implant Placements Using CAD/CAM Surgical Guides.

    Science.gov (United States)

    Alzoubi, Fawaz; Massoomi, Nima; Nattestad, Anders

    2016-10-01

    The aim of this study is to assess the accuracy of immediately placed implants using Anatomage Invivo5 computer-assisted design/computer-assisted manufacturing (CAD/CAM) surgical guides and compare the accuracy to delayed implant placement protocol. Patients who had implants placed using Anatomage Invivo5 CAD/CAM surgical guides during the period of 2012-2015 were evaluated retrospectively. Patients who received immediate implant placements and/or delayed implant placements replacing 1-2 teeth were included in this study. Pre- and postsurgical images were superimposed to evaluate deviations at the crest, apex, and angle. A total of 40 implants placed in 29 patients were included in this study. The overall mean deviations measured at the crest, apex, and angle were 0.86 mm, 1.25 mm, and 3.79°, respectively. The means for the immediate group deviations were: crest = 0.85 mm, apex = 1.10, and angle = 3.49°. The means for the delayed group deviations were: crest = 0.88 mm, apex = 1.59, and angle = 4.29°. No statistically significant difference was found at the crest and angle; however, there was a statistically significant difference between the immediate and delayed group at the apex, with the immediate group presenting more accurate placements at the apical point than the delayed group. CAD/CAM surgical guides can be reliable tools to accurately place implants immediately and/or in a delayed fashion. No statistically significant differences were found between the delayed and the immediate group at the crest and angle, however apical position was more accurate in the immediate group.

  1. Porous Structure Characterization in Titanium Coating for Surgical Implants

    Directory of Open Access Journals (Sweden)

    M.V. Oliveira

    2002-09-01

    Full Text Available Powder metallurgy techniques have been used to produce controlled porous structures, such as the porous coatings applied for dental and orthopedic surgical implants, which allow bony tissue ingrowth within the implant surface improving fixation. This work presents the processing and characterization of titanium porous coatings of different porosity levels, processed through powder metallurgy techniques. Pure titanium sponge powders were used for coating and Ti-6Al7Nb powder metallurgy rods were used as substrates. Characterization was made through quantitative metallographic image analysis using optical light microscope for coating porosity data and SEM analysis for evaluation of the coating/substrate interface integrity. The results allowed optimization of the processing parameters in order to obtain porous coatings that meet the requirements for use as implants.

  2. Surgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma.

    Science.gov (United States)

    Yadgarov, Arkadiy; Liu, Dan; Crane, Elliot S; Khouri, Albert S

    2017-01-01

    To describe postoperative surgical success of either Ahmed or Baerveldt tube shunt implantation for eyes with medically uncontrolled traumatic glaucoma. A review was carried out to identify patients with traumatic glaucoma that required tube shunt implantation between 2009 and 2015 at Rutgers University in Newark, New Jersey, USA. Seventeen eyes from 17 patients met inclusion criteria, including at least 3-month postoperative follow-up. The main outcome measure was surgical success at 1-year follow-up after tube implantation. Mean preoperative intraocular pressure (IOP) was 34.1 ± 8.2 mm Hg on 3.1 ± 1.6 ocular hypotensive medications. Nine eyes (53%) sustained closed globe injury. Ten eyes (59%) received an Ahmed valve shunt and seven eyes (41%) received a Baerveldt tube shunt. Surgical success rate at 1 year postoperatively was 83%. Compared to preoperative, the mean postoperative IOP was significantly lower (16.1 ± 3.5 mm Hg, p Ahmed or Baerveldt tube shunt provided successful control of IOP in patients with medically uncontrollable traumatic glaucoma. Yadgarov A, Liu D, Crane ES, Khouri AS. Surgical Outcomes of Ahmed or Baerveldt Tube Shunt Implantation for medically Uncontrolled Traumatic Glaucoma. J Curr Glaucoma Pract 2017;11(1):16-21.

  3. Surgical complications after peritoneal dialysis catheter implantation depend on children's weight.

    Science.gov (United States)

    Radtke, Josephine; Lemke, Anja; Kemper, Markus J; Nashan, Bjoern; Koch, Martina

    2016-08-01

    Surgical complications are estimated to be as high as 30%-40% during the first 8 weeks after implantation of peritoneal dialysis (PD) catheters. 70 PD catheters which were implanted by transplant surgeons in 61 children (median age 3.3years, range 0.01-15.5years, 31 boys and 30 girls) in 2009-2014 were retrospectively reviewed. The incidence of complications and revisions during the first 6months after implantation was analyzed depending on children's weight and diagnosis. 17 out of 70 catheters needed a surgical revision within 6months after implantation (24.3%). Peritonitis was the most common complication affecting 18.6% of peritoneal dialysis catheters followed by obstruction and dislocation, which it occurred in 9 (12.9%) and 7 (10%) catheters, respectively. Leakage (n=5) only occurred in children with a weight of less than 10kg. The total proportion of complications was higher in children with less than 10kg of weight (P<0.001). PD is safe in children with acute renal failure and older children with chronic renal failure; however children with a weight of less than 10kg are more likely to develop complications. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Surgical positioning of orthodontic mini-implants with guides fabricated on models replicated with cone-beam computed tomography.

    Science.gov (United States)

    Kim, Seong-Hun; Choi, Yong-Suk; Hwang, Eui-Hwan; Chung, Kyu-Rhim; Kook, Yoon-Ah; Nelson, Gerald

    2007-04-01

    This article illustrates a new surgical guide system that uses cone-beam computed tomography (CBCT) images to replicate dental models; surgical guides for the proper positioning of orthodontic mini-implants were fabricated on the replicas, and the guides were used for precise placement. The indications, efficacy, and possible complications of this method are discussed. Patients who were planning to have orthodontic mini-implant treatment were recruited for this study. A CBCT system (PSR 9000N, Asahi Roentgen, Kyoto, Japan) was used to acquire virtual slices of the posterior maxilla that were 0.1 to 0.15 mm thick. Color 3-dimensional rapid prototyping was used to differentiate teeth, alveolus, and maxillary sinus wall. A surgical guide for the mini-implant was fabricated on the replica model. Proper positioning for mini-implants on the posterior maxilla was determined by viewing the CBCT images. The surgical guide was placed on the clinical site, and it allowed precise pilot drilling and accurate placement of the mini-implant. CBCT imaging allows remarkably lower radiation doses and thinner acquisition slices compared with medical computed tomography. Virtually reproduced replica models enable precise planning for mini-implant positions in anatomically complex sites.

  5. XEN Gel Implant: a new surgical approach in glaucoma.

    Science.gov (United States)

    Chaudhary, Ankita; Salinas, Lauriane; Guidotti, Jacopo; Mermoud, André; Mansouri, Kaweh

    2018-01-01

    Glaucoma is a leading cause of blindness worldwide. Intraocular pressure (IOP) lowering is the only effective treatment strategy. Traditional glaucoma surgeries are generally considered to be unpredictable and associated with a high rate of complications. This has led to the development of a novel XEN Gel Implant, a type of minimally invasive glaucoma surgery (MIGS), lowering the IOP without extensive surgical dissection. Areas covered: A literature search was undertaken on PubMed using the terms XEN glaucoma, gelatin microstent, and MIGS. All the articles and case reports on XEN Gel Implant and selected articles on MIGS were studied and reviewed. We have discussed the results of most studies on XEN Gel Implant related to its efficacy, safety and success. Expert commentary: The XEN Gel Implant effectively lowers IOP and medication use, with a favorable safety profile. Long-term data on its success and cost-effectiveness are lacking. The studies have shown it to be without any serious adverse events and to have good safety profile encouraging future research on this novel implant. There is a need to correctly identify selection criteria for patients, who would benefit the most from the XEN Gel Implant.

  6. Decrease of Staphylococcal adhesion on surgical stainless steel after Si ion implantation

    International Nuclear Information System (INIS)

    Braceras, Iñigo; Pacha-Olivenza, Miguel A.; Calzado-Martín, Alicia; Multigner, Marta; Vera, Carolina; Broncano, Luis Labajos-; Gallardo-Moreno, Amparo M.; González-Carrasco, José Luis; Vilaboa, Nuria

    2014-01-01

    Highlights: • Si ion implantation of AISI 316LVM medical grade alloy might reduce bacterial adhesion and colonization. • Si ion implantation does not impair the attachment, viability and matrix maturation of human mesenchymal stem cells. • Nano-topography and surface chemistry changes account for the Si ion implantation induced effects. - Abstract: 316LVM austenitic stainless steel is often the material of choice on temporal musculoskeletal implants and surgical tools as it combines good mechanical properties and acceptable corrosion resistance to the physiologic media, being additionally relatively inexpensive. This study has aimed at improving the resistance to bacterial colonization of this surgical stainless steel, without compromising its biocompatibility and resistance. To achieve this aim, the effect of Si ion implantation on 316LVM has been studied. First, the effect of the ion implantation parameters (50 keV; fluence: 2.5–5 × 10 16 ions/cm 2 ; angle of incidence: 45–90°) has been assessed in terms of depth profiling of chemical composition by XPS and nano-topography evaluation by AFM. The in vitro biocompatibility of the alloy has been evaluated with human mesenchymal stem cells. Finally, bacterial adhesion of Staphylococcus epidermidis and Staphylococcus aureus on these surfaces has been assessed. Reduction of bacterial adhesion on Si implanted 316LVM is dependent on the implantation conditions as well as the features of the bacterial strains, offering a promising implantable biomaterial in terms of biocompatibility, mechanical properties and resistance to bacterial colonization. The effects of surface composition and nano-topography on bacterial adhesion, directly related to ion implantation conditions, are also discussed

  7. Decrease of Staphylococcal adhesion on surgical stainless steel after Si ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Braceras, Iñigo, E-mail: inigo.braceras@tecnalia.com [Tecnalia, Mikeletegi Pasealekua 2, 20009 Donostia-San Sebastian (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Pacha-Olivenza, Miguel A. [CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Universidad de Extremadura, Departamento de Física Aplicada, Facultad de Ciencias, Av. Elvas s/n, 06006 Badajoz (Spain); Calzado-Martín, Alicia [Hospital Universitario La Paz-IdiPAZ, Paseo de la Castellana 261, 28046 Madrid (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Multigner, Marta [Centro Nacional de Investigaciones Metalúrgicas, CENIM-CSIC, Avda Gregorio del Amo 8, 28040 Madrid (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Vera, Carolina [Tecnalia, Mikeletegi Pasealekua 2, 20009 Donostia-San Sebastian (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Broncano, Luis Labajos-; Gallardo-Moreno, Amparo M. [Universidad de Extremadura, Departamento de Física Aplicada, Facultad de Ciencias, Av. Elvas s/n, 06006 Badajoz (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); González-Carrasco, José Luis [Centro Nacional de Investigaciones Metalúrgicas, CENIM-CSIC, Avda Gregorio del Amo 8, 28040 Madrid (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); Vilaboa, Nuria [Hospital Universitario La Paz-IdiPAZ, Paseo de la Castellana 261, 28046 Madrid (Spain); CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN) (Spain); and others

    2014-08-15

    Highlights: • Si ion implantation of AISI 316LVM medical grade alloy might reduce bacterial adhesion and colonization. • Si ion implantation does not impair the attachment, viability and matrix maturation of human mesenchymal stem cells. • Nano-topography and surface chemistry changes account for the Si ion implantation induced effects. - Abstract: 316LVM austenitic stainless steel is often the material of choice on temporal musculoskeletal implants and surgical tools as it combines good mechanical properties and acceptable corrosion resistance to the physiologic media, being additionally relatively inexpensive. This study has aimed at improving the resistance to bacterial colonization of this surgical stainless steel, without compromising its biocompatibility and resistance. To achieve this aim, the effect of Si ion implantation on 316LVM has been studied. First, the effect of the ion implantation parameters (50 keV; fluence: 2.5–5 × 10{sup 16} ions/cm{sup 2}; angle of incidence: 45–90°) has been assessed in terms of depth profiling of chemical composition by XPS and nano-topography evaluation by AFM. The in vitro biocompatibility of the alloy has been evaluated with human mesenchymal stem cells. Finally, bacterial adhesion of Staphylococcus epidermidis and Staphylococcus aureus on these surfaces has been assessed. Reduction of bacterial adhesion on Si implanted 316LVM is dependent on the implantation conditions as well as the features of the bacterial strains, offering a promising implantable biomaterial in terms of biocompatibility, mechanical properties and resistance to bacterial colonization. The effects of surface composition and nano-topography on bacterial adhesion, directly related to ion implantation conditions, are also discussed.

  8. Physiological Stress Responses to Prolonged Exposure to MS-222 and Surgical Implantation in Juvenile Chinook Salmon

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Katie A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Woodley, Christa M. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Seaburg, Adam [Univ. of Washington, Seattle, WA (United States); Skalski, John R. [Univ. of Washington, Seattle, WA (United States); Eppard, Matthew B. [U.S. Army Corps of Engineers, Portland, OR (United States)

    2014-07-17

    While many studies have investigated the effects of transmitters on fish condition, behavior, and survival, to our knowledge, no studies have taken into account anesthetic exposure time in addition to tag and surgery effects. We investigated stress responses to prolonged MS-222 exposure after stage 4 induction in surgically implanted juvenile Chinook salmon (Oncorhynchus tshawytscha). Survival, tag loss, plasma cortisol concentration, and blood Na+, K+, Ca2+, and pH were measured immediately following anesthetic exposure and surgical implantation and 1, 7, and 14 days post-treatment. Despite the prolonged anesthetic exposure, 3-15 minutes post Stage 4 induction, there were no mortalities or tag loss in any treatment. MS-222 was effective at delaying immediate cortisol release during surgical implantation; however, osmotic disturbances resulted, which were more pronounced in longer anesthetic time exposures. From day 1 to day 14, Na+, Ca2+, and pH significantly decreased, while cortisol significantly increased. The cortisol increase was exacerbated by surgical implantation. There was a significant interaction between MS-222 time exposure and observation day for Na+, Ca2+, K+, and pH; variations were seen in the longer time exposures, although not consistently. In conclusion, stress response patterns suggest stress associated with surgical implantation is amplified with increased exposure to MS-222.

  9. Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol

    Directory of Open Access Journals (Sweden)

    Corina Marilena Cristache

    2017-01-01

    Full Text Available The aim of this study was to evaluate the accuracy of a stereolithographic template, with sleeve structure incorporated into the design, for computer-guided dental implant insertion in partially edentulous patients. Materials and Methods. Sixty-five implants were placed in twenty-five consecutive patients with a stereolithographic surgical template. After surgery, digital impression was taken and 3D inaccuracy of implants position at entry point, apex, and angle deviation was measured using an inspection tool software. Mann–Whitney U test was used to compare accuracy between maxillary and mandibular surgical guides. A p value < .05 was considered significant. Results. Mean (and standard deviation of 3D error at the entry point was 0.798 mm (±0.52, at the implant apex it was 1.17 mm (±0.63, and mean angular deviation was 2.34 (±0.85. A statistically significant reduced 3D error was observed at entry point p=.037, at implant apex p=.008, and also in angular deviation p=.030 in mandible when comparing to maxilla. Conclusions. The surgical template used has proved high accuracy for implant insertion. Within the limitations of the present study, the protocol for comparing a digital file (treatment plan with postinsertion digital impression may be considered a useful procedure for assessing surgical template accuracy, avoiding radiation exposure, during postoperative CBCT scanning.

  10. Long-Term Mortality Effect of Early Pacemaker Implantation After Surgical Aortic Valve Replacement.

    Science.gov (United States)

    Greason, Kevin L; Lahr, Brian D; Stulak, John M; Cha, Yong-Mei; Rea, Robert F; Schaff, Hartzell V; Dearani, Joseph A

    2017-10-01

    The need for pacemaker implantation is a well-described complication of aortic valve replacement. Not so well described is the effect such an event has on long-term outcome. This study reviewed a 21-year experience at the Mayo Clinic (Rochester, Minnesota) with aortic valve replacement to understand the influence of early postoperative pacemaker implantation on long-term mortality rates more clearly. This study retrospectively reviewed the records of 5,842 patients without previous pacemaker implantation who underwent surgical aortic valve replacement from January 1993 through June 2014. The median age of these patients was 73 years (range, 65 to 79 years), the median ejection fraction was 62% (range, 53% to 68%), 3,853 patients were male (66%), and coronary artery bypass graft operation was performed in 2,553 (44%) of the patients studied. Early pacemaker implantation occurred in 146 patients (2.5%) within 30 days of surgical aortic valve replacement. The median follow-up of patients was 11.1 years (range, 5.8 to 16.5 years), and all-cause mortality rates were 2.4% at 30 days, 6.4% at 1 year, 23.1% at 5 years, 48.3% at 10 years, and 67.9% at 15 years postoperatively. Early pacemaker implantation was associated with an increased risk of death after multivariable adjustment for baseline patients' characteristics (hazard ratio, 1.49; 95% confidence interval, 1.20, 1.84; p pacemaker implantation as a complication of surgical aortic valve replacement is associated with an increased risk of long-term death. Valve replacement-related pacemaker implantation rates should be important considerations with respect to new valve replacement paradigms, especially in younger and lower-risk patients. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Transcatheter aortic valve prosthesis surgically replaced 4 months after implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Lund, Jens Teglgaard; Engstrøm, Thomas

    2010-01-01

    Transcatheter aortic valve implantation is a new and rapidly evolving treatment option for high-risk surgical patients with degenerative aortic valve stenosis. Long-term results with these new valve prostheses are lacking, and potential valve dysfunction and failure would require valve replacemen...

  12. Bone Reduction to Facilitate Immediate Implant Placement and Loading Using CAD/CAM Surgical Guides for Patients With Terminal Dentition.

    Science.gov (United States)

    Alzoubi, Fawaz; Massoomi, Nima; Nattestad, Anders

    2016-10-01

    The aim of this study is to present a method, using 3 computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guides, to accurately obtain the desired bone reduction followed by immediate implant placements and loading for patients diagnosed with terminal dentition. Patients who had bone reduction, implants placed, and immediate loading using Anatomage Invivo 5 CAD/CAM surgical guides between the period 2013 and 2015 were evaluated retrospectively. Patients diagnosed with terminal dentition and treated using the "3-guide technique" were identified. Pre- and postsurgical images were superimposed to evaluate deviations of the bone reduction and deviations at the crest, apex, and angle of implants placed. Twenty-six implants placed in 5 patients were included in this study. The overall deviation means measured for bone reduction was 1.98 mm. The overall deviation means measured for implant placement at the crest, apex, and angle were 1.43 mm, 1.90 mm, and 4.14°, respectively. The CAD/CAM surgical guide fabrication is an emerging tool that may facilitate the surgical process and aid in safe and predictable execution of bone reduction and immediate implant placement. Using 3 CAD/CAM surgical guides, a method is presented to obtain the desired bone reduction followed by immediate implant placement and loading for patients diagnosed with terminal dentition. This method may improve guide stability for patients with terminal dentition undergoing complete implant-supported treatment by taking advantage of the teeth to be extracted.

  13. Soft and Hard Tissue Management in Implant Therapy—Part I: Surgical Concepts

    Directory of Open Access Journals (Sweden)

    Antonio D'Addona

    2012-01-01

    Full Text Available Implant therapy has become a reliable and predictable treatment alternative for the replacement of missing teeth with conventional removable and fixed partial dentures. Recently though, in the pursuit for improved esthetics, the literature has dedicated a considerable amount of its research on the successful maintenance and regeneration of the surrounding gingiva and bone, which are lost following extraction of a tooth. Thoroughly analyzing the anatomic situation and well-planned treatment has become a requirement, because incorrectly planned and positioned implants may jeopardize long-term esthetic and functional prognosis. In addition, many types of biocompatible materials, autogenous hard and soft tissue grafts, and different surgical techniques have been developed, and their viability has been investigated. As a result, implant specialists have gained a greater understanding of the dynamics and anatomical and biological concepts of the periodontium and peri-implant tissues both at the surgical and prosthetic phases of treatment, which contributes to better soft and hard tissue management (SHTM. This may further contribute to achieving a superior final result which is obtained by having a harmonious soft tissue profile, a correctly placed and contoured final restoration, and the reestablishment of masticatory function and phonetics.

  14. Three-Year Outcome of Fixed Partial Rehabilitations Supported by Implants Inserted with Flap or Flapless Surgical Techniques.

    Science.gov (United States)

    Maló, Paulo; de Araújo Nobre, Miguel; Lopes, Armando

    2016-07-01

    The aim of this prospective clinical study was to evaluate the 3-year outcome of fixed partial prostheses supported by implants with immediate provisionalization without occlusal contacts inserted in predominantly soft bone with flap and flapless protocols. Forty-one patients partially rehabilitated with 72 NobelSpeedy implants (51 maxillary; 21 mandibular) were consecutively included and treated with a flapless surgical protocol (n = 20 patients; 32 implants) and flapped surgical protocol (n = 21 patients; 40 implants). Primary outcome measure was implant survival; secondary outcome measures were marginal bone resorption (comparing the bone levels at 1 and 3 years with baseline) and the incidence of biological, mechanical, and esthetic complications. Survival was computed through life tables; descriptive statistics were applied to the remaining variables of interest. Eight patients with eight implants dropped out of the study. One implant failed in one patient (flapless group) giving an overall cumulative survival rate (CSR) of 98.6%. No failures were noted with the flapped protocol (CSR 100%), while for the implants placed with the flapless surgical technique, a 96.9% CSR was registered. The overall average marginal bone resorption at 3 years was 1.37 mm (SD = 0.94 mm), with 1.14 mm (SD = 0.49 mm) and 1.60 mm (SD = 1.22 mm) for the flap and flapless groups, respectively. Mechanical complications occurred in nine patients (n = 5 patients in the flapless group; n = 4 patients in the flap group). Implant infection was registered in three implants and three patients (flapless group), who exhibited inadequate oral hygiene levels. Partial edentulism rehabilitation through immediate provisionalization fixed prosthesis supported by dental implants inserted through flap or flapless surgical techniques in areas of predominantly soft bone was viable at 3 years of follow-up. The limitations and risks of the "free-hand" method in flapless surgery should be considered when

  15. Optimization in multi-implant placement for immediate loading in edentulous arches using a modified surgical template and prototyping: a case report.

    Science.gov (United States)

    Jayme, Sérgio J; Muglia, Valdir A; de Oliveira, Rafael R; Novaes, Arthur B Júnior

    2008-01-01

    Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance throughout the treatment period. Placement of dental implants requires precise planning that accounts for anatomic limitations and restorative goals. Diagnosis can be made with the assistance of computerized tomographic scanning, but transfer of planning to the surgical field is limited. Recently, novel CAD/CAM techniques such as stereolithographic rapid prototyping have been developed to build surgical guides in an attempt to improve precision of implant placement. The aim of this case report was to show a modified surgical template used throughout implant placement as an alternative to a conventional surgical guide.

  16. The surgical viability and radiological monitoring of brain implants of bioactive micro-seeds in an animal model

    International Nuclear Information System (INIS)

    Silva, Giane X.O.; Campos, Tarcisio Passos Ribeiro de; Siqueira, Savio Lana; Maciel, Marcelo B.

    2005-01-01

    The interstitial implant is a therapeutic modality in brachytherapy of the head and neck. Presently, the seeds implanted in tumors in the central nervous system are metallic I-125. After the full emission of the radionuclide, the seed remains inert in the implanted area. Bioactive ceramic seeds have been prepared for this research group incorporating Sm-152 to be active in Sm-153. The main goal of the present study is the development of a the surgical technique for implanting the biodegradable radioactive micro-seeds in the brains of rabbits, as well as the observation of the clinical reactions of the animal after implantation of two sets of three seeds. The surgical procedure consisted of performing two separate perforations 10 mm from each other in the skull, permitting the implantation of two groups of three seeds, totaling six seeds. The results of the pilot study showed the effectiveness of the surgical procedure and of the biocompatibility of the seeds and the lack of presence of adverse reactions, functional sequels, or inflammation in a follow up 50 days post-surgery. Such seeds of reduced volume, 0.2 x 1.6 mm, could be monitored by computerized tomography 30 days after implanting. (author)

  17. The Suprameatal Approach: A Safe Alternative Surgical Technique for Cochlear Implantation

    NARCIS (Netherlands)

    Postelmans, Job T. F.; Tange, Rinze A.; Stokroos, Robert J.; Grolman, Wilko

    2010-01-01

    Objective: To report on surgical complications arising post-operatively in 104 patients undergoing cochlear implantation surgery using the suprameatal approach (SMA). Second, to examine the advantages and disadvantages of the SMA technique compared with the classic mastoidectomy using the posterior

  18. Surgical Treatment of Peri-Implantitis: A 17-Year Follow-Up Clinical Case Report

    Directory of Open Access Journals (Sweden)

    Fabrizio Bassi

    2015-01-01

    Full Text Available The purpose of the present case report was to describe the surgical treatment of a peri-implantitis lesion associated with a regenerative approach. A 48-year-old patient came to authors’ attention 36 months after the placement of a dental implant (ITI-Bonefit Straumann, Waldenburg, Switzerland in position 46. A swelling of the peri-implant soft tissues was observed, associated with bleeding on probing and probing depth > 10 mm. A significant peri-implant bone loss was clearly visible on the periapical radiograph. A nonsurgical periodontal supportive therapy was firstly conducted to reduce the inflammation, followed by the surgical treatment of the defect. After mechanical and chemical decontamination with tetracycline solution, a regenerative approach consisting in the application of deproteinized bovine bone mineral (Bio-Oss, Geistlich Pharma AG, Wolhusen, Switzerland and a collagen membrane (Bio-Gide, Geistlich Pharma AG, Wolhusen, Switzerland was performed. An antibiotic therapy was associated with the treatment. The 17-year follow-up showed a physiological probing depth with no clinical signs of peri-implant inflammation and bleeding on probing. No further radiographic bone loss was observed. The treatment described in the present case report seemed to show improved clinical results up to a relevant follow-up period.

  19. Surgical Outcome of Ahmed Valve Implantation in Mexican Patients with Neovascular Glaucoma.

    Science.gov (United States)

    Hernandez-Oteyza, Alejandra; Lazcano-Gomez, Gabriel; Jimenez-Roman, Jesus; Hernandez-Garciadiego, Carlos

    2014-01-01

    To describe clinical results of Ahmed glaucoma valve implantation in Mexican patients with neovascular glaucoma (NVG). We reviewed records of 60 eyes of 60 patients with NVG who underwent Ahmed valve implantation, with a follow-up period of 1 year. We identified successful and failed cases and compared baseline and follow-up characteristics to identify possible differences between both groups. We classified 36 eyes (60%) as successful and 24 (40%) as failed cases. We found a significant difference in success rate in patients who had a hypertensive phase at any time during the follow-up period (OR = 5.15, CI = 1.49-20.15, p = 0.004). Patients in the success group showed a statistically significant decrease in the number of glaucoma medications 1 year after surgery (p Ahmed valve surgical failure in patients with NVG. How to cite this article: Hernandez-Oteyza A, Lazcano-Gomez G, Jimenez-Roman J, Hernandez-Garciadiego C. Surgical Outcome of Ahmed Valve Implantation in Mexican Patients with Neovascular Glaucoma. J Curr Glaucoma Pract 2014;8(3):86-90.

  20. USE OF PLASTIC MATERIAL AND TRIPLE SCAN IN THE PREPARATION OF SURGICAL GUIDES FOR THE DENTAL IMPLANT TREATMENT-CASE REPORT

    Directory of Open Access Journals (Sweden)

    Rosen Borisov

    2016-09-01

    Full Text Available The use of surgical guides in implant treatment increases the accuracy of the dental implant positioning compared with manual methods. Regardless of how they are made, deviations of implants from their intended position are established in all kinds of surgical guides. This article considers the use of plastic material and new scanning technique for the production of CAD/CAM surgical guides that aim to overcome the deficiencies of the currently applied technologies in the production of surgical guides. Materials and methods: The study shows the techniques used to overcome degraded by metal artifacts CBCT images in implant treatment of patients with partial edentulism, and located medially to the defect metal-ceramic crowns. When planning implant treatment, a triple scan method has been implied. At the beginning, CBCT scan of the patient with a silicone impression material is made in the zone of interest. Secondly, CBCT scan only of the silicon impression is made, and thirdly - intraoral scanning of the patient with an intraoral scanner. Virtual analogues have been created of images from the three scans and have been repositioned one over another; as thereby an intraoral image have been accurately positioned over the CBCT image of the patient. Virtual planning of the implant positioning has been performed, and a model of surgical guide has been made for their placement. The guide has been printed with an SLA 3D printer technology of photopolymer with dualistic characteristics-rigid in the working part and plastic in the fixing part. Through it, implants have been placed to the treatment planning. Postoperative CBCT has been done on the patient to measure the implant deviation to their position in the treatment planning. Results: Axes angular deviation of the planned and placed implants has not been established. Average linear displacement of 240 μ (+/- 40 μ has been found. Conclusions: Using the triple scan method is possible to overcome the

  1. Surgical management of fibrotic encapsulation of the fluocinolone acetonide implant in CAPN5-associated proliferative vitreoretinopathy

    Directory of Open Access Journals (Sweden)

    Tlucek PS

    2013-06-01

    Full Text Available Paul S Tlucek,1 James C Folk,1 Warren M Sobol,2 Vinit B Mahajan1,3 1Department of Ophthalmology and Visual Sciences, University of Iowa, Iowa City, IA, USA; 2Retina Physicians and Surgeons, Dayton, OH, USA; 3Omics Laboratory, University of Iowa, Iowa City, IA, USA Objective: To review fibrosis of fluocinolone acetonide (FA implants in subjects with CAPN5 autosomal dominant neovascular inflammatory vitreoretinopathy (ADNIV. Methods: A retrospective case series was assembled from ADNIV patients in which there was fibrotic encapsulation of a fluocinolone acetonide implant. CAPN5 genotypes and surgical repair techniques were reviewed. Results: Two eyes of two ADNIV patients developed a fibrotic capsule over the fluocinolone acetonide implant. Both patients had Stage IV disease. Patient A had a c.731T > C mutation in the CAPN5 gene and patient B had a c.728G > T mutation. The fibrotic membrane was surgically excised and the implant function was restored. Conclusion: The exuberant fibrotic response in later stages of ADNIV may be resistant to local immunosuppression with steroids. Surgical excision of fibrotic membranes over FA implants can reestablish local steroid delivery in cases of severe proliferative vitreoretinopathy. Keywords: autosomal dominant neovascular inflammatory vitreoretinopathy, ADNIV, CAPN5, calpain-5, Retisert, fluocinolone acetonide, fibrotic encapsulation

  2. Characterization of the ODS MA 956 superalloy for biomedical surgical implants

    International Nuclear Information System (INIS)

    Escudero, M.L.; Ruiz, J.; Gonzalez-Carrasco, J.L.; Chao, J.; Lopez, M.F.; Garcia-Alonso, M.C.; Canahua, H.; Adeva, P.; Coedo, A.G.; Dorado, M.T.; Rubio, J.C.; Martinez, M.E.; Munuera, L.; Agustin, D. de; Ruiz, J.

    1998-01-01

    Since the MA 956 was proposed as a possible new biomaterial due to its good corrosion resistance values in physiological fluids a long way, still not finished, has been done. An exhaustive characterization of this alloy at room temperature has been developed. The technological objectives are well established: the possible use of this material for biomedical as hip or knee prostheses and as dental implants. The study was performed comparing the results of this alloy with the materials used nowadays as surgical implants, i.e., titanium alloys and polyethylene. (Author) 5 refs

  3. Virtual surgical planning and 3D printing in prosthetic orbital reconstruction with percutaneous implants: a technical case report.

    Science.gov (United States)

    Huang, Yu-Hui; Seelaus, Rosemary; Zhao, Linping; Patel, Pravin K; Cohen, Mimis

    2016-01-01

    Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis.

  4. Virtual surgical planning and 3D printing in prosthetic orbital reconstruction with percutaneous implants: a technical case report

    Directory of Open Access Journals (Sweden)

    Huang Y

    2016-10-01

    Full Text Available Yu-Hui Huang,1,2 Rosemary Seelaus,1,2 Linping Zhao,1,2 Pravin K Patel,1,2 Mimis Cohen1,2 1The Craniofacial Center, Department of Surgery, Division of Plastic & Reconstructive Surgery, University of Illinois Hospital & Health Sciences System, 2University of Illinois College of Medicine at Chicago, Chicago, IL, USA Abstract: Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis. Keywords: computer-assisted surgery, virtual surgical planning (VSP, 3D printing, orbital prosthetic reconstruction, craniofacial implants

  5. 3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study.

    Science.gov (United States)

    Schnutenhaus, Sigmar; Edelmann, Cornelia; Rudolph, Heike; Dreyhaupt, Jens; Luthardt, Ralph G

    2018-01-22

    The aim of this study was to investigate differences between the virtually planned and clinically achieved implant positions in completely template-guided implantations as a function of the type of edentulous space, the residual natural dentition, and the surgical implementation. Fifty-six patient cases with a total of 122 implants were evaluated retrospectively. The implantations were completely template-based. The data of the planned implant positions were overlaid with the actual clinical implant positions, followed by measurements of the 3D deviations in terms of coronal (x c ) and apical distance, height (x h ), and angulation (ang) and statistical analysis. The mean x c was 1.2 mm (SD 0.7 mm); the mean x a was 1.8 mm (SD 0.9 mm), the mean x h was 0.8 mm (SD 0.7 mm); and the mean ang was 4.8° (SD 3.1). The type of edentulous space and the jaw (maxilla/mandible) had no significant effect on the results in terms of implant positions. The presence of an adjacent natural tooth at the time of implantation had a significant influence on x h (p = 0.04) and ang (p = 0.05). No significant differences were found regarding the surgical approach for any of the parameters examined. The results of our study are in the same range as those of other studies. Template-guided implantation offers a high degree of accuracy even in the presence of different configurations of the residual dentition or different surgical approaches. A clinical benefit is therefore present, especially from a prosthetic point of view. The clinically achievable accuracy can be described as sufficient for further prosthetic treatment, given the intrinsic and methodological tolerances, making prosthetic rehabilitation safe and predictable.

  6. Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure.

    Science.gov (United States)

    Huang, Jingjing; Lin, Jialiu; Wu, Ziqiang; Xu, Hongzhi; Zuo, Chengguo; Ge, Jian

    2015-01-01

    The purpose of this study was to evaluate the intermediate surgical results of Ahmed glaucoma valve (AGV) implantation in patients less than 7 years of age, with advanced primary congenital glaucoma who have failed previous surgeries. Consecutive patients with advanced primary congenital glaucoma that failed previous operations and had undergone subsequent AGV implantation were evaluated retrospectively. Surgical success was defined as 1) intraocular pressure (IOP) ≥6 and ≤21 mmHg; 2) IOP reduction of at least 30% relative to preoperative values; and 3) without the need for additional surgical intervention for IOP control, loss of light perception, or serious complications. Fourteen eyes of eleven patients were studied. Preoperatively, the average axial length was 27.71±1.52 (25.56-30.80) mm, corneal diameter was 14.71±1.07 (13.0-16.0) mm, cup-to-disc ratio was 0.95±0.04 (0.9-1.0), and IOP was 39.5±5.7 (30-55) mmHg. The mean follow-up time was 18.29±10.96 (5-44, median 18) months. There were significant reductions in IOPs and the number of glaucoma medications (Pvalve success were 85.7%, 71.4%, and 71.4% at 6, 12, and 18 months, respectively. Severe surgical complications, including erosion of tube, endophthalmitis, retinal detachment, choroidal detachment, and delayed suprachoroidal hemorrhage, occurred in 28.6% cases. AGV implantation remains a viable option for patients with advanced primary congenital glaucoma unresponsive to previous surgical intervention, despite a relatively high incidence of severe surgical complications.

  7. Surgical considerations and safety of cochlear implantation in otitis media with effusion.

    Science.gov (United States)

    Cevizci, Rasit; Dilci, Alper; Celenk, Fatih; Karamert, Recep; Bayazit, Yildirim

    2018-06-01

    To evaluate the effects of otitis media with effusion on surgical parameters, patient safety, perioperative and postoperative complications. Total 890 children who underwent cochlear implantation between 2006 and 2015 were included. The ages ranged from 12 months to 63 months (mean: 32 months). The patients were divided into two groups according to the presence or absence of otitis media with effusion; otitis media with effusion group and non-otitis media group. Of 890 children, 105 had otitis media with effusion prior to surgery. In non-otitis media with group, there were 785 children. The average duration of surgery was 60min (ranged from 28 to 75min) in non-otitis media group, and 90min (ranged from 50 to 135min) in otitis media with effusion group (peffusion during the surgery. There was no significant difference between the complications of groups with or without otitis media with effusion (p>0.05). In 5 of 105 patients, there was a ventilation tube inserted before cochlear implantation, which did not change the outcome of implantation. There is no need for surgical treatment for otitis media with effusion before implantation since otitis media with effusion does not increase the risks associated with cochlear implantation. Operation duration is longer in the presence of otitis media with effusion. However, otitis media with effusion leads to intraoperative difficulties like longer operation duration, bleeding, visualization of the round window membrane, cleansing the middle ear granulations as well as mastoid and petrous air cells. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Placement of fin type dental implant in three different surgical situations of alveolar bone

    Directory of Open Access Journals (Sweden)

    Coen Pramono D

    2007-03-01

    Full Text Available Three different dental implant placements according to surgical implant bed situations were observed in its bone integration 3 months after dental implant insertion. This observation was done on implant system which has plateau or fin system. Elf implants were placed in the upper jaw in two patients. In case one, two implants were inserted immediately after tooth extraction, and the other six implants were placed in the alveolar crest regions in delayed implantation or in which the teeth had been extracted over 6 months of period. In case two, three implants were inserted in the post trauma region in the anterior maxilla, which the labial plate had been lost and reconstructed with bone grafting procedure using a mixture of alloplastic and autogenous bones. The alveolar reconstruction was needed to be performed due to only thin alveolar crest width was left intact. All of those implants observed showed in good integration.

  9. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips.

    Science.gov (United States)

    Gill, Amreeta; Shellock, Frank G

    2012-01-09

    Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC) and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC) that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information) among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants) underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration). Heating was not substantial (highest temperature change, ≤ 1.6°C). Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants.

  10. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips

    Directory of Open Access Journals (Sweden)

    Gill Amreeta

    2012-01-01

    Full Text Available Abstract Purpose Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. Methods A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Results Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration. Heating was not substantial (highest temperature change, ≤ 1.6°C. Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. Conclusions The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants.

  11. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips

    Science.gov (United States)

    2012-01-01

    Purpose Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. Methods A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC) and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC) that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information) among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants) underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Results Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration). Heating was not substantial (highest temperature change, ≤ 1.6°C). Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. Conclusions The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants. PMID:22230200

  12. The Efficacy of Ultraviolet Radiation for Sterilizing Tools Used for Surgically Implanting Transmitters into Fish

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Ricardo W.; Markillie, Lye Meng; Colotelo, Alison HA; Gay, Marybeth E.; Woodley, Christa M.; Brown, Richard S.

    2013-02-28

    Telemetry is frequently used to examine the behavior of fish, and the transmitters used are normally surgically implanted into the coelom of fish. Implantation requires the use of surgical tools such as scalpels, forceps, needle holders, and sutures. When several fish are implanted consecutively for large telemetry studies, it is common for surgical tools to be sterilized or, at minimum, disinfected between each use so that pathogens that may be present are not spread among fish. However, autoclaving tools can take a long period of time, and chemical sterilants or disinfectants can be harmful to both humans and fish and have varied effectiveness. Ultraviolet (UV) radiation is commonly used to disinfect water in aquaculture facilities. However, this technology has not been widely used to sterilize tools for surgical implantation of transmitters in fish. To determine its efficacy for this application, Pacific Northwest National Laboratory researchers used UV radiation to disinfect surgical tools (i.e., forceps, needle holder, stab scalpel, and suture) that were exposed to one of four aquatic organisms that typically lead to negative health issues for salmonids. These organisms included Aeromonas salmonicida, Flavobacterium psychrophilum, Renibacterium salmoninarum, and Saprolegnia parasitica. Surgical tools were exposed to the bacteria by dipping them into a confluent suspension of three varying concentrations (i.e., low, medium, high). After exposure to the bacterial culture, tools were placed into a mobile Millipore UV sterilization apparatus. The tools were then exposed for three different time periods—2, 5, or 15 min. S. parasitica, a water mold, was tested using an agar plate method and forceps-pinch method. UV light exposures of 5 and 15 min were effective at killing all four organisms. UV light was also effective at killing Geobacillus stearothermophilus, the organism used as a biological indicator to verify effectiveness of steam sterilizers. These

  13. Fractal analysis of the surgical treatment of ligature-induced peri-implantitis in dogs

    International Nuclear Information System (INIS)

    Kim, Hak Kun; Kim, Jin Soo

    2010-01-01

    To evaluate the effect of surgical treatment of ligature-induced peri-implantitis in dogs using fractal analysis. Also, the capabilities of fractal analysis as bone analysis techniques were compared with those of histomorphometric analysis. A total of 24 implants were inserted in 6 dogs. After a 3-months, experimental periimplantitis characterized by a bone loss of about 3 mm was established by inducing with wires. Surgical treatment involving flap procedure, debridement of implants surface with chlorhexidine and saline (group 1), guided bone regeneration (GBR) with absorbable collagen membrane and mineralized bone graft (group 2), and CO2 laser application with GBR (group 3) were performed. After animals were sacrificed in 8 and 16 weeks respectively, bone sections including implants were made. Fractal dimensions were calculated by box-counting method on the skeletonized images, made from each region of interest, including five screws at medial and distal aspects of implant, were selected. Statistically significant differences in the fractal dimensions between the group 1 (0.9340 ± 0.0126) and group 3 (0.9783 ± 0.0118) at 16 weeks were found (P<0.05). The fractal dimension was statistically significant different between 8 (0.9395 ± 0.0283) and 16 weeks in group 3 (P<0.05). These results were similar with the result of the evaluation of new bone formation in histomorphometric analysis. Treatment of experimental peri-implantitis by using CO2 laser with GBR is more useful than other treatments in the formation of new bone and also the tendency of fractal dimension to increase relative to healing time may be a useful means of evaluating.

  14. Fractal analysis of the surgical treatment of ligature-induced peri-implantitis in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hak Kun; Kim, Jin Soo [School of Dentisity, Chosun University, Gwangju (Korea, Republic of)

    2010-09-15

    To evaluate the effect of surgical treatment of ligature-induced peri-implantitis in dogs using fractal analysis. Also, the capabilities of fractal analysis as bone analysis techniques were compared with those of histomorphometric analysis. A total of 24 implants were inserted in 6 dogs. After a 3-months, experimental periimplantitis characterized by a bone loss of about 3 mm was established by inducing with wires. Surgical treatment involving flap procedure, debridement of implants surface with chlorhexidine and saline (group 1), guided bone regeneration (GBR) with absorbable collagen membrane and mineralized bone graft (group 2), and CO2 laser application with GBR (group 3) were performed. After animals were sacrificed in 8 and 16 weeks respectively, bone sections including implants were made. Fractal dimensions were calculated by box-counting method on the skeletonized images, made from each region of interest, including five screws at medial and distal aspects of implant, were selected. Statistically significant differences in the fractal dimensions between the group 1 (0.9340 {+-} 0.0126) and group 3 (0.9783 {+-} 0.0118) at 16 weeks were found (P<0.05). The fractal dimension was statistically significant different between 8 (0.9395 {+-} 0.0283) and 16 weeks in group 3 (P<0.05). These results were similar with the result of the evaluation of new bone formation in histomorphometric analysis. Treatment of experimental peri-implantitis by using CO2 laser with GBR is more useful than other treatments in the formation of new bone and also the tendency of fractal dimension to increase relative to healing time may be a useful means of evaluating.

  15. The clinical outcomes of surgical management of anterior chamber migration of a dexamethasone implant (Ozurdex®).

    Science.gov (United States)

    Kang, Hyunseung; Lee, Min Woo; Byeon, Suk Ho; Koh, Hyoung Jun; Lee, Sung Chul; Kim, Min

    2017-09-01

    Our purpose was to describe the clinical course, and individualized management approaches, of patients with migration of a dexamethasone implant into the anterior chamber. This was a retrospective review of four patients with seven episodes of anterior chamber migration of a dexamethasone implant. After 924 intravitreal dexamethasone injections, anterior migration of the implant occurred in four eyes of four patients (0.43%). All four eyes were pseudophakic: one eye had a posterior chamber intraocular lens in the capsular bag but in a post-laser posterior capsulotomy state, two eyes had a sulcus intraocular lens (IOL), and one eye had an iris-fixated retropupillary IOL. All eyes had a prior vitrectomy and no lens capsule. The time interval from injection to detection of the implant migration ranged from 2 to 6 weeks. Of the four eyes with corneal edema, only one eye required a corneal transplantation, although it was unclear whether the implant migration was the direct cause of the corneal decompensation because the patient had a history of bullous keratopathy resulting from an extended history of uveitis. All patients underwent surgical intervention: two patients with a repositioning procedure, and the other two patients with removal due to repeated episodes, although surgical removal was not always necessary to reverse the corneal complications. In our study, not all patients required surgical removal of the implants. Repositioning the implant back into the vitreous cavity may be considered as an option in cases involving the first episode with no significant corneal endothelial decompensation. Considering potential anterior segment complications and the loss of drug effectiveness together, an individualized approach is recommended to obtain the best treatment outcomes and to minimize the risk of corneal complications.

  16. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...... and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83...

  17. Surgical site infection in orthopedic implants and its common bacteria with their sensitivities to antibiotics, in open reduction internal fixation

    International Nuclear Information System (INIS)

    Shah, M.Q.; Zardad, M.S.; Khan, A.; Ahmed, S.; Awan, A. S.; Mohammad, T.

    2017-01-01

    Surgical site infection in orthopaedic implants is a major problem, causing long hospital stay, cost to the patient and is a burden on health care facilities. It increases rate of non-union, osteomyelitis, implant failure, sepsis, multiorgan dysfunction and even death. Surgical site infection is defined as pain, erythema, swelling and discharge from wound site. Surgical site infection in orthopaedic implants is more challenging to the treating orthopaedic surgeon as the causative organism is protected by a biofilm over the implant's surface. Antibiotics cannot cross this film to reach the bacteria's, causing infection. Method: This descriptive case series study includes 132 patients of both genders with ages between 13 years to 60 years conducted at Orthopaedic Unit, Ayub Medical College, Abbottabad from 1st October 2015 to 31st March 2016. Patients with close fractures of long bones were included in the study to determine the frequency of surgical site infection in orthopaedic implants and the type of bacteria involved and their sensitivity to various antibiotics. All implants were of stainless steel. The implants used were Dynamic hip screws, Dynamic compression screws, plates, k-wires, Interlocking nails, SIGN nails, Austin Moore prosthesis and tension band wires. Pre-op and post-op antibiotics used were combination of Sulbactum and Cefoperazone which was given 1 hour before surgery and continued for 72 hours after surgery. Patients were followed up to 4 weeks. Pus was taken on culture stick, from those who developed infection. Results were entered in the pro forma. Results: A total of 132 patients of long bone fractures, who were treated with open reduction and internal fixation, were studied. Only 7 patients developed infection. Staphylococcus Aureus was isolated from all 7 patients. Staphylococcus aureus was sensitive to Linezolid, Fusidic Acid, and vancomycin. Cotrimoxazole, tetracycline, Gentamycin and Clindamycin were partially effective. Conclusion

  18. The effects of local nitroglycerin on the surgical delay procedure in prefabricated flaps by vascular implant in rats.

    Science.gov (United States)

    Sá, Jairo Zacchê de; Aguiar, José Lamartine de Andrade; Cruz, Adriana Ferreira; Schuler, Alexandre Ricardo Pereira; Lima, José Ricardo Alves de; Marques, Olga Martins

    2012-12-01

    To evaluate the effect of local nitroglycerin on the viable area of a prefabricated flap for vascular implant in rats, and to investigate the surgical delay procedure. A femoral pedicle was implanted under the skin of the abdominal wall in forty Wistar rats. The animals were divided into four groups of ten: group 1 - without surgical delay procedure and local nitroglycerin; group 2 - with surgical delay procedure, but without local nitroglycerin; group 3 - without surgical delay procedure, but with local nitroglycerin; and group 4 - with simultaneous surgical delay procedure and local nitroglycerin. The percentages of the viable areas, in relation to the total flap, were calculated using AutoCAD R 14. The mean percentage value of the viable area was 8.9% in the group 1. 49.4% in the group 2; 8.4% in the group 3 and 1.1% in the group 4. There was significant difference between groups 1 and 2 (p=0.005), 1 and 4 (p=0.024), 2 and 3 (p=0.003), 2 and 4 (p=0.001). These results support the hypothesis that the closure of the arterial venous channels is responsible for the phenomenon of surgical delay procedure. Local nitroglycerin did not cause an increase in the prefabricated viable flap area by vascular implantation and decreased the viable flap area that underwent delay procedures.

  19. [The evolution of surgical interventions for cochlear implantation at the Russian Research and Practical Centre of Audiology and Hearing Rehabilitation].

    Science.gov (United States)

    Fedoseev, V I; Dmitriev, N S

    2014-01-01

    The objective of the present study was to estimate and analyse the effectiveness and labour intensity of the methods of surgical intervention for cochlear implantation. The analysis of the surgical stage of cochlear implantation was based on the examination of 2073 children and adults during the period from 1991 to 2013. The age of the patients varied between 6 months to 71 years. The cause of deafness was meningitis and an injury in 11% and 6% of the patients respectively. The cochlear implants from Advanced Bionics were inserted in 495 patients, those from Med-El in 9 ones , and from Neurelec in 20, and Nucleus devices from Cochlear in the remaining patents (n=1549) including 37 double-array electrodes and a Hybrid implant for electroacoustic correction of hearing . The implants with a straight and perimodiolar electrode were placed in a roughly equal number of the patients. The rationale for the performance of selected components of the surgical stage of cochlear implantation was developed along with the technical procedures for the purpose applied at this Centre since 1991. The original methods for the fixation and covering of the receiver-stimulator and also for the choice of the place of the electrode array insertion into the cochlea are described. They allowed to significantly decrease the frequency of complications, duration and extent of the surgical intervention as well as to reduce to a minimum post-operative manipulations.

  20. Intra-Arterial Hepatic Chemotherapy: A Comparison of Percutaneous Versus Surgical Implantation of Port-Catheters

    International Nuclear Information System (INIS)

    Deschamps, F.; Elias, D.; Goere, D.; Malka, D.; Ducreux, M.; Boige, V.; Auperin, A.; Baere, T. de

    2011-01-01

    Purpose: To compare retrospectively the safety and efficacy of percutaneous and surgical implantations of port-catheters for intra-arterial hepatic chemotherapy (IAHC). Materials and Methods: Between January 2004 and December 2008, 126 consecutive patients (mean age 58 years) suffering from liver colorectal metastases were referred for intra-arterial hepatic chemotherapy (IAHC). Port-catheters were percutaneously implanted (P) through femoral access with the patient under conscious sedation when no other surgery was planned or were surgically implanted (S) when laparotomy was performed for another purpose. We report the implantation success rate, primary functionality, functionality after revision, and complications of IAHC. Results: The success rates of implantation were 97% (n = 65 of 67) for P and 98% (n = 58 of 59) for S. One hundred eleven patients received IAHC in our institution (n = 56P and n = 55S). Primary functionality was the same for P and S (4.80 vs. 4.82 courses), but functionality after revision was significantly higher for P (9.18 vs. 5.95 courses, p = 0.004) than for S. Forty-five complications occurred during 516 courses for P and 28 complications occurred during 331 courses for S. The rates of discontinuation of IAHC linked to complications of the port-catheters were 21% (n = 12 of 56) for P and 34% (n = 19 of 55) for S. Conclusion: Overall, significantly better functionality and similar complication rates occurred after P versus S port-catheters.

  1. The nordic aortic valve intervention (NOTION) trial comparing transcatheter versus surgical valve implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Søndergaard, Lars; Ihlemann, Nikolaj

    2013-01-01

    Degenerative aortic valve (AV) stenosis is the most prevalent heart valve disease in the western world. Surgical aortic valve replacement (SAVR) has until recently been the standard of treatment for patients with severe AV stenosis. Whether transcatheter aortic valve implantation (TAVI) can...

  2. Factors influencing immediate post-release survival of spectacled eiders following surgical implantation of transmitters with percutaneous antennae

    Science.gov (United States)

    Sexson, Matthew G.; Mulcahy, Daniel M.; Spriggs, Maria; Myers, Gwen E.

    2014-01-01

    Surgically implanted transmitters are a common method for tracking animal movements. Immediately following surgical implantation, animals pass through a critical recovery phase when behaviors may deviate from normal and the likelihood of individual survival may be reduced. Therefore, data collected during this period may be censored to minimize bias introduced by surgery-related behaviors or mortality. However, immediate post-release mortalities negate a sampling effort and reduce the amount of data potentially collected after the censoring period. Wildlife biologists should employ methods to support an animal’s survival through this period, but factors contributing to immediate post-release survival have not been formally assessed. We evaluated factors that potentially influenced the immediate post-release survival of 56 spectacled eiders (Somateria fischeri) marked with coelomically implanted satellite transmitters with percutaneous antennae in northern Alaska in 2010 and 2011. We modeled survival through the first 14 days following release and assessed the relative importance and effect of 15 covariates hypothesized to influence survival during this immediate post-release period. Estimated daily survival rate increased over the duration of the immediate post-release period; the probability of mortality was greatest within the first 5 days following release. Our top-ranking model included the effect of 2 blood analytes, pH and hematocrit, measured prior to surgical implantation of a transmitter. We found a positive response to pH; eiders exhibiting acidemia (low pH) prior to surgery were less likely to survive the immediate post-release period. We found a curvilinear response to hematocrit; eiders exhibiting extremely low or high pre-surgery hematocrit were also less likely to survive the immediate post-release period. In the interest of maximizing the survival of marked birds following release, hematological data obtained prior to surgical implantation of

  3. Patient-Specific Surgical Implants Made of 3D Printed PEEK: Material, Technology, and Scope of Surgical Application

    Directory of Open Access Journals (Sweden)

    Philipp Honigmann

    2018-01-01

    Full Text Available Additive manufacturing (AM is rapidly gaining acceptance in the healthcare sector. Three-dimensional (3D virtual surgical planning, fabrication of anatomical models, and patient-specific implants (PSI are well-established processes in the surgical fields. Polyetheretherketone (PEEK has been used, mainly in the reconstructive surgeries as a reliable alternative to other alloplastic materials for the fabrication of PSI. Recently, it has become possible to fabricate PEEK PSI with Fused Filament Fabrication (FFF technology. 3D printing of PEEK using FFF allows construction of almost any complex design geometry, which cannot be manufactured using other technologies. In this study, we fabricated various PEEK PSI by FFF 3D printer in an effort to check the feasibility of manufacturing PEEK with 3D printing. Based on these preliminary results, PEEK can be successfully used as an appropriate biomaterial to reconstruct the surgical defects in a “biomimetic” design.

  4. Patient-Specific Surgical Implants Made of 3D Printed PEEK: Material, Technology, and Scope of Surgical Application.

    Science.gov (United States)

    Honigmann, Philipp; Sharma, Neha; Okolo, Brando; Popp, Uwe; Msallem, Bilal; Thieringer, Florian M

    2018-01-01

    Additive manufacturing (AM) is rapidly gaining acceptance in the healthcare sector. Three-dimensional (3D) virtual surgical planning, fabrication of anatomical models, and patient-specific implants (PSI) are well-established processes in the surgical fields. Polyetheretherketone (PEEK) has been used, mainly in the reconstructive surgeries as a reliable alternative to other alloplastic materials for the fabrication of PSI. Recently, it has become possible to fabricate PEEK PSI with Fused Filament Fabrication (FFF) technology. 3D printing of PEEK using FFF allows construction of almost any complex design geometry, which cannot be manufactured using other technologies. In this study, we fabricated various PEEK PSI by FFF 3D printer in an effort to check the feasibility of manufacturing PEEK with 3D printing. Based on these preliminary results, PEEK can be successfully used as an appropriate biomaterial to reconstruct the surgical defects in a "biomimetic" design.

  5. CT-guided localization of small pulmonary nodules using adjacent microcoil implantation prior to video-assisted thoracoscopic surgical resection

    Energy Technology Data Exchange (ETDEWEB)

    Su, Tian-Hao; Jin, Long; He, Wen [Capital Medical University, Department of Radiology, Beijing Friendship Hospital, Beijing (China); Fan, Yue-Feng [Xiamen University, Department of Interventional Therapy, The First Affiliated Hospital, Xiamen, Fujian (China); Hu, Li-Bao [Peking University People' s Hospital, Department of Radiology, Beijing (China)

    2015-09-15

    To describe and assess the localization of small peripheral pulmonary nodules prior to video-assisted thoracoscopic surgical (VATS) resection using the implantation of microcoils. Ninety-two patients with 101 pulmonary nodules underwent computed tomography (CT)-guided implantation of microcoils proximal to each nodule. Patients were randomly assigned to undergo entire microcoil or leaving-microcoil-end implantations. The complications and efficacy of the two implantation methods were evaluated. VATS resection of lung tissue containing each pulmonary lesion and microcoil were performed in the direction of the microcoil marker. Histopathological analysis was performed for the resected pulmonary lesions. CT-guided microcoil implantation was successful in 99/101 cases, and the placement of microcoils within 1 cm of the nodules was not disruptive. There was no difference in the complications and efficacy associated with the entire implantation method (performed for 51/99 nodules) versus the leaving-microcoil-end implantation method (performed for 48/99 nodules). All nodules were successfully removed using VATS resection. Asymptomatic pneumothorax occurred in 16 patients and mild pulmonary haemorrhage occurred in nine patients. However, none of these patients required further surgical treatment. Preoperative localization of small pulmonary nodules using a refined percutaneous microcoil implantation method was found to be safe and useful prior to VATS resection. (orig.)

  6. Stratification of risk to the surgical team in removal of small arms ammunition implanted in the craniofacial region: case report.

    Science.gov (United States)

    Forbes, Jonathan A; Laughlin, Ian; Newberry, Shane; Ryhn, Michael; Pasley, Jason; Newberry, Travis

    2016-09-01

    In cases of penetrating injury with implantation of small arms ammunition, it can often be difficult to tell the difference between simple ballistics and ballistics associated with unexploded ordnances (UXOs). In the operative environment, where highly flammable substances are often close to the surgical site, detonation of UXOs could have catastrophic consequences for both the patient and surgical team. There is a paucity of information in the literature regarding how to evaluate whether an implanted munition contains explosive material. This report describes a patient who presented during Operation Enduring Freedom with an implanted munition suspicious for a UXO and the subsequent workup organized by Explosive Ordnance Disposal (EOD) Company prior to surgical removal. Clinical risk factors for UXOs include assassination attempts and/or wartime settings. Specific radiological features suggestive of a UXO include projectile size greater than 7.62-mm caliber, alterations in density of the tip, as well as radiological evidence of a hollowed-out core. If an implanted UXO is suspected, risks to the surgical and anesthesia teams can be minimized by notifying the nearest military installation with EOD capabilities and following clinical practice guidelines set forth by the Joint Theater Trauma System.

  7. Surgical results of trabeculectomy and Ahmed valve implantation following a previous failed trabeculectomy in primary congenital glaucoma patients.

    Science.gov (United States)

    Lee, Naeun; Ma, Kyoung Tak; Bae, Hyoung Won; Hong, Samin; Seong, Gong Je; Hong, Young Jae; Kim, Chan Yun

    2015-04-01

    To compare the surgical results of trabeculectomy and Ahmed glaucoma valve implantation after a previous failed trabeculectomy. A retrospective comparative case series review was performed on 31 eye surgeries in 20 patients with primary congenital glaucoma who underwent trabeculectomy or Ahmed glaucoma valve implantation after a previous failed trabeculectomy with mitomycin C. The preoperative mean intraocular pressure was 25.5 mmHg in the trabeculectomy group and 26.9 mmHg in the Ahmed glaucoma valve implantation group (p = 0.73). The 48-month postoperative mean intraocular pressure was 19.6 mmHg in the trabeculectomy group and 20.2 mmHg in the Ahmed glaucoma valve implantation group (p = 0.95). The 12-month trabeculectomy success rate was 69%, compared with 64% for Ahmed glaucoma valve implantation, and the 48-month success rates were 42% and 36% for trabeculectomy and valve implantation, respectively. The success rates following the entire follow-up period were not significantly different between the two groups (p > 0.05 by log rank test). Postoperative complications occurred in 25% of the trabeculectomy-operated eyes and 9% of the Ahmed-implanted eyes (p = 0.38). There was no significant difference in surgical outcome between the trabeculectomy and Ahmed glaucoma valve implantation groups, neither of which had favorable results. However, the trabeculectomy group demonstrated a higher prevalence of adverse complications such as post-operative endophthalmitis.

  8. Assessment of the Quality of Newly Formed Bone around Titanium Alloy Implants by Using X-Ray Photoelectron Spectroscopy

    Directory of Open Access Journals (Sweden)

    Hiroshi Nakada

    2012-01-01

    Full Text Available The aim of this study was to evaluate differences in bones quality between newly formed bone and cortical bone formed around titanium alloy implants by using X-ray photoelectron spectroscopy. As a result of narrow scan measurement at 4 weeks, the newly formed bone of C1s, P2p, O1s, and Ca2p were observed at a different peak range and strength compared with a cortical bone. At 8 weeks, the peak range and strength of newly formed bone were similar to those of cortical bone at C1s, P2p, and Ca2p, but not O1s. The results from this analysis indicate that the peaks and quantities of each element of newly formed bone were similar to those of cortical bone at 8 weeks, suggestive of a strong physicochemical resemblance.

  9. Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure

    Science.gov (United States)

    Huang, Jingjing; Lin, Jialiu; Wu, Ziqiang; Xu, Hongzhi; Zuo, Chengguo; Ge, Jian

    2015-01-01

    Purpose The purpose of this study was to evaluate the intermediate surgical results of Ahmed glaucoma valve (AGV) implantation in patients less than 7 years of age, with advanced primary congenital glaucoma who have failed previous surgeries. Patients and methods Consecutive patients with advanced primary congenital glaucoma that failed previous operations and had undergone subsequent AGV implantation were evaluated retrospectively. Surgical success was defined as 1) intraocular pressure (IOP) ≥6 and ≤21 mmHg; 2) IOP reduction of at least 30% relative to preoperative values; and 3) without the need for additional surgical intervention for IOP control, loss of light perception, or serious complications. Results Fourteen eyes of eleven patients were studied. Preoperatively, the average axial length was 27.71±1.52 (25.56–30.80) mm, corneal diameter was 14.71±1.07 (13.0–16.0) mm, cup-to-disc ratio was 0.95±0.04 (0.9–1.0), and IOP was 39.5±5.7 (30–55) mmHg. The mean follow-up time was 18.29±10.96 (5–44, median 18) months. There were significant reductions in IOPs and the number of glaucoma medications (Pglaucoma unresponsive to previous surgical intervention, despite a relatively high incidence of severe surgical complications. PMID:26082610

  10. A Review of the Ahmed Glaucoma Valve Implant and Comparison with Other Surgical Operations.

    Science.gov (United States)

    Riva, Ivano; Roberti, Gloria; Katsanos, Andreas; Oddone, Francesco; Quaranta, Luciano

    2017-04-01

    The Ahmed glaucoma valve (AGV) is a popular glaucoma drainage implant used for the control of intraocular pressure in patients with glaucoma. While in the past AGV implantation was reserved for glaucoma patients poorly controlled after one or more filtration procedures, mounting evidence has recently encouraged its use as a primary surgery in selected cases. AGV has been demonstrated to be safe and effective in reducing intraocular pressure in patients with primary or secondary refractory glaucoma. Compared to other glaucoma surgeries, AGV implantation has shown favorable efficacy and safety. The aim of this article is to review the results of studies directly comparing AGV with other surgical procedures in patients with glaucoma.

  11. Assessment of wrought ASTM F1058 cobalt alloy properties for permanent surgical implants.

    Science.gov (United States)

    Clerc, C O; Jedwab, M R; Mayer, D W; Thompson, P J; Stinson, J S

    1997-01-01

    The behavior of the ASTM F1058 wrought cobalt-chromium-nickel-molybdenum-iron alloy (commonly referred to as Elgiloy or Phynox) is evaluated in terms of mechanical properties, magnetic resonance imaging, corrosion resistance, and biocompatibility. The data found in the literature, the experimental corrosion and biocompatibility results presented in this article, and its long track record as an implant material demonstrate that the cobalt superalloy is an appropriate material for permanent surgical implants that require high yield strength and fatigue resistance combined with high elastic modulus, and that it can be safely imaged with magnetic resonance.

  12. Transcatheter aortic valve implantation for failing surgical aortic bioprosthetic valve: from concept to clinical application and evaluation (part 2).

    Science.gov (United States)

    Piazza, Nicolo; Bleiziffer, Sabine; Brockmann, Gernot; Hendrick, Ruge; Deutsch, Marcus-André; Opitz, Anke; Mazzitelli, Domenico; Tassani-Prell, Peter; Schreiber, Christian; Lange, Rüdiger

    2011-07-01

    This study sought to review the acute procedural outcomes of patients who underwent transcatheter aortic valve (TAV)-in-surgical aortic valve (SAV) implantation at the German Heart Center, Munich, and to summarize the existing literature on TAV-in-SAV implantation (n = 47). There are several case reports and small case series describing transcatheter aortic valve implantation for a failing surgical aortic valve bioprosthesis (TAV-in-SAV implantation). From January 2007 to March 2011, 20 out of 556 patients underwent a TAV-in-SAV implantation at the German Heart Center Munich. Baseline characteristics and clinical outcome data were prospectively entered into a dedicated database. The mean patient age was 75 ± 13 years, and the mean logistic European System for Cardiac Operative Risk Evaluation and Society of Thoracic Surgeons' Risk Model scores were 27 ± 13% and 7 ± 4%, respectively. Of the 20 patients, 14 had stented and 6 had stentless surgical bioprostheses. Most cases (12 of 20) were performed via the transapical route using a 23-mm Edwards Sapien prosthesis (Edwards Lifesciences, Irvine, California). Successful implantation of a TAV in a SAV with the patient leaving the catheterization laboratory alive was achieved in 18 of 20 patients. The mean transaortic valve gradient was 20.0 ± 7.5 mm Hg. None-to-trivial, mild, and mild-to-moderate paravalvular aortic regurgitation was observed in 10, 6, and 2 patients, respectively. We experienced 1 intraprocedural death following pre-implant balloon aortic valvuloplasty ("stone heart") and 2 further in-hospital deaths due to myocardial infarction. TAV-in-SAV implantation is a safe and feasible treatment for high-risk patients with failing aortic bioprosthetic valves and should be considered as part of the armamentarium in the treatment of aortic bioprosthetic valve failure. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Immediate prostheses on one-piece trans-mucosal implants in flapless surgical procedures Case Series Report. Part I: full arch rehabilitations

    Directory of Open Access Journals (Sweden)

    Aris Petros Tripodakis

    2012-06-01

    Full Text Available Aim: The aim of the present case series report is to illustrate a clinical technique and present the application of onepiece transmucosal implants in flapless surgical procedures, supporting full arch immediate prostheses. Materials and methods: A total of 294 implants (Xive TG, Friadent, Germany have been used to support full arch immediate prostheses, over the last six years and have been in function for at least one year. The surgical placement of five or more implants per case involved immediate extraction and intrasocket flapless placement, combined with minimal flap elevation in the areas of healed extraction sites (43 mandibular and 7 maxillary arches. In all cases immediate provisionalization followed. Detailed three-dimensional cone-beam localized volumetric tomography preceeded the surgical procedures. The delivery of the final ceramo-metal prostheses was accomplished within a 20 day period. Materials and methods: Results Six implants failed to osseointegrate. All other implants are still successfully bearing the final prosthesis for the time that they have been followed. Soft tissue reaction was favorable from both the biologic and esthetic point of view. Conclusion: The flapless placement of one piece implants into edentulous healed sites is a predictable procedure in the presence of abundance of supporting bone as confirmed by 3-D imaging. On the other hand, immediate extraction placement of one piece implants allows the engagement of sound bone located deeper into the socket and provides adequate mechanical support of the soft tissue architecture that is preserved predictably. In all cases the prosthetic procedures are accomplished without disturbing the hardsoft tissue interface as the abutment-prosthesis interface is coronally elevated by the virtual design of the implant.

  14. Evaluation of distributed practice schedules on retention of a newly acquired surgical skill: a randomized trial.

    Science.gov (United States)

    Mitchell, Erica L; Lee, Dae Y; Sevdalis, Nick; Partsafas, Aaron W; Landry, Gregory J; Liem, Timothy K; Moneta, Gregory L

    2011-01-01

    practice influences new skill acquisition. The aim of this study was to prospectively investigate the impact of practice distribution (weekly vs monthly) on complex motor skill (end-side vascular anastomosis) acquisition and 4-month retention. twenty-four surgical interns were randomly assigned to weekly training for 4 weeks or monthly training for 4 months, with equal total training times. Performance was assessed before training, immediately after training, after the completion of distributed training, and 4 months later. there was no statistical difference in surgical skill acquisition and retention between the weekly and monthly scheduled groups, as measured by procedural checklist scores, global rating scores of operative performance, final product analysis, and overall performance or assessment of operative "competence." distributed practice results in improvement and retention of a newly acquired surgical skill independent of weekly or monthly practice schedules. Flexibility in a surgical skills laboratory curriculum is possible without adversely affecting training. 2011 Elsevier Inc. All rights reserved.

  15. Surgical Regenerative Treatments for Peri-Implantitis: Meta-analysis of Recent Findings in a Systematic Literature Review

    Directory of Open Access Journals (Sweden)

    Povilas Daugela

    2016-09-01

    Full Text Available Objectives: The purpose of the present study was to systematically review the literature on the surgical regenerative treatment of the peri-implantitis and to determine an effective therapeutic predictable option for their clinical management. Material and Methods: The study searched MEDLINE and EMBASE databases from 2006 to 2016. Clinical human studies that had reported changes in probing depth (PD and/or bleeding on probing (BOP and/or radiologic marginal bone level (RBL changes after peri-implantitis surgical treatment at 12-month follow-up or longer were included accordingly to PRISMA guidelines. Results: The initial search obtained 883 citations. After screening and determination of eligibility, 18 articles were included in the review. The meta-analysis of selected studies revealed that the weighted mean RBL fill was 1.97 mm (95% confidence interval [CI] = 1.58 to 2.35 mm, PD reduction was 2.78 mm (95% CI = 2.31 to 3.25 mm, and BOP reduced by 52.5% (95% CI = 41.6 to 63.1%. Defect fill in studies using and not using barrier membranes for graft coverage was 1.86 mm (95% CI = 1.36 to 2.36 mm and 2.12 mm (95% CI = 1.46 to 2.78 mm correspondingly. High heterogeneity among the studies regarding defects morphology, surgical protocols, and selection of biomaterials were found. Conclusions: All included studies underlined an improvement of clinical conditions after the surgical regenerative treatment of peri-implantitis, however, there is a lack of scientific evidence in the literature regarding the superiority of the regenerative versus non-regenerative surgical treatment. The presence of a barrier membrane or submergence in the regenerative procedure does not seem to be fundamental in order to obtain clinical success of the surgery.

  16. Two-year clinical outcomes following non-surgical mechanical therapy of peri-implantitis with adjunctive diode laser application.

    Science.gov (United States)

    Mettraux, Gérald R; Sculean, Anton; Bürgin, Walter B; Salvi, Giovanni E

    2016-07-01

    Non-surgical mechanical therapy of peri-implantitis (PI) with/without adjunctive measures yields limited clinical improvements. To evaluate the clinical outcomes following non-surgical mechanical therapy of PI with adjunctive application of a diode laser after an observation period ≥2 years. At baseline (BL), 15 patients with 23 implants with a sandblasted and acid-etched (SLA) surface diagnosed with PI were enrolled and treated. PI was defined as presence of probing pocket depths (PPD) ≥5 mm with bleeding on probing (BoP) and/or suppuration and ≥2 threads with bone loss after delivery of the restoration. Implant sites were treated with carbon fiber and metal curettes followed by repeated application of a diode laser 3x for 30 s (settings: 810 nm, 2.5 W, 50 Hz, 10 ms). This procedure was performed at Day 0 (i.e., baseline), 7 and 14. Adjunctive antiseptics or adjunctive systemic antibiotics were not prescribed. All implants were in function after 2 years. The deepest PPD decreased from 7.5 ± 2.6 mm to 3.6 ± 0.7 mm at buccal (P surgical mechanical therapy of PI with adjunctive repeated application of a diode laser yielded significant clinical improvements after an observation period of at least 2 years. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Inferior Alveolar Nerve Lateralization and Transposition for Dental Implant Placement. Part I: a Systematic Review of Surgical Techniques

    Directory of Open Access Journals (Sweden)

    Boris Abayev

    2015-03-01

    Full Text Available Objectives: The purpose of this first part of a two-part series was to review the literature concerning the indications, contraindications, advantages, disadvantages and surgical techniques of the lateralization and transposition of the inferior alveolar nerve, followed by the placement of an implant in an edentulous atrophic posterior mandible. Material and Methods: A comprehensive review of the current literature was conducted according to the PRISMA guidelines by accessing the NCBI PubMed and PMC database, academic sites and books. The articles were searched from January 1997 to July 2014 and comprised English-language articles that included adult patients between 18 and 80 years old with minimal residual bone above the mandibular canal who had undergone inferior alveolar nerve (IAN repositioning with a minimum 6 months of follow-up. Results: A total of 16 studies were included in this review. Nine were related to IAN transposition, 4 to IAN lateralization and 3 to both transposition and lateralization. Implant treatment results and complications were presented. Conclusions: Inferior alveolar nerve lateralization and transposition in combination with the installation of dental implants is sometimes the only possible procedure to help patients to obtain a fixed prosthesis, in edentulous atrophic posterior mandibles. With careful pre-operative surgical and prosthetic planning, imaging, and extremely precise surgical technique, this procedure can be successfully used for implant placement in edentulous posterior mandibular segments.

  18. Load-Bearing Capacity and Retention of Newly Developed Micro-Locking Implant Prosthetic System: An In Vitro Pilot Study

    Directory of Open Access Journals (Sweden)

    Jae-Won Choi

    2018-04-01

    Full Text Available The aim of this study was to introduce the newly developed micro-locking implant prosthetic system and to evaluate the resulting its characteristics. To evaluate load-bearing capacity, 25 implants were divided into five groups: external-hexagon connection (EH, internal-octagon connection (IO, internal-hexagon connection (IH, one-body implant (OB, micro-locking implant system (ML. The maximum compressive load was measured using a universal testing machine (UTM according to the ISO 14801. Retention was evaluated in two experiments: (1 a tensile test of the structure modifications of the components (attachment and implant and (2 a tensile test after cyclic loading (total 5,000,000 cycles, 100 N, 2 Hz. The load-bearing capacity of the ML group was not significantly different from the other groups (p > 0.05. The number of balls in the attachment and the presence of a hexagonal receptacle did not show a significant correlation with retention (p > 0.05, but the shape of the retentive groove in the implant post had a statistically significant effect on retention (p < 0.05. On the other hand, the retention loss was observed during the initial 1,000,000 cycles, but an overall constant retention was maintained afterward. Various preclinical studies on this novel micro-locking implant prosthetic system should continue so that it can be applied in clinical practice.

  19. Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure

    Directory of Open Access Journals (Sweden)

    Huang J

    2015-06-01

    Full Text Available Jingjing Huang,1 Jialiu Lin,1 Ziqiang Wu,2 Hongzhi Xu,3 Chengguo Zuo,1 Jian Ge1 1State Key Laboratory of Ophthalmology, Department of Glaucoma, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, People’s Republic of China; 2Center for Advanced Eye Care, Carson City, NV, USA; 3Institute of Child Health Policy, University of Florida, Gainesville, FL, USA Purpose: The purpose of this study was to evaluate the intermediate surgical results of Ahmed glaucoma valve (AGV implantation in patients less than 7 years of age, with advanced primary congenital glaucoma who have failed previous surgeries.Patients and methods: Consecutive patients with advanced primary congenital glaucoma that failed previous operations and had undergone subsequent AGV implantation were evaluated retrospectively. Surgical success was defined as 1 intraocular pressure (IOP ≥6 and ≤21 mmHg; 2 IOP reduction of at least 30% relative to preoperative values; and 3 without the need for additional surgical intervention for IOP control, loss of light perception, or serious complications.Results: Fourteen eyes of eleven patients were studied. Preoperatively, the average axial length was 27.71±1.52 (25.56–30.80 mm, corneal diameter was 14.71±1.07 (13.0–16.0 mm, cup-to-disc ratio was 0.95±0.04 (0.9–1.0, and IOP was 39.5±5.7 (30–55 mmHg. The mean follow-up time was 18.29±10.96 (5–44, median 18 months. There were significant reductions in IOPs and the number of glaucoma medications (P<0.001 postoperatively. The IOPs after operation were 11.3±3.4, 13.6±5.1, 16.3±2.7, and 16.1±2.6 mmHg at 1 month, 6 months, 12 months, and 18 months, respectively. Kaplan–Meier estimates of the cumulative probability of valve success were 85.7%, 71.4%, and 71.4% at 6, 12, and 18 months, respectively. Severe surgical complications, including erosion of tube, endophthalmitis, retinal detachment, choroidal detachment, and delayed suprachoroidal hemorrhage, occurred in 28

  20. Re-implant of the right coronary artery: a surgical technique for the treatment of ostial lesions

    Directory of Open Access Journals (Sweden)

    Bongiovani Hércules Lisboa

    2002-01-01

    Full Text Available Previously described surgical treatment for ostial coronary artery stenosis relied on either venous or arterial bypasses or ostial patch angioplasty. These surgical procedures are performed with bovine pericardium, saphenous vein or internal thoracic artery. We describe a technique of right coronary artery re-implantation into the aorta. The procedure was performed in four patients with right coronary artery ostial stenosis along with other left coronary artery lesions.

  1. Non-surgical treatment of peri-implantitis with the adjunctive use of an 810-nm diode laser

    Directory of Open Access Journals (Sweden)

    Marisa Roncati

    2013-01-01

    Full Text Available An 810-nm diode laser was used to non-surgically treat a 7-mm pocket around an implant that had five threads of bone loss, BoP+, and exudate, and the patient was followed up for 5 years. Non-surgical treatment, home care reinforcement, clinical indices records, and radiographic examination were completed in two consecutive 1-h appointments within 24 h. The patient was monitored frequently for the first 3 months. Subsequently, maintenance debridement visits were scheduled at 3-month intervals. The patient had a decreased probing pocket depth and a negative BoP index compared to initial clinical data, and the results were stable after 1 year. After 5 years of follow-up visits, there appeared to be rebound of the bone level radiographically. Within the limits of this case report, conventional non-surgical periodontal therapy with the adjunctive use of an 810-nm diode laser may be a feasible alternative approach for the management of peri-implantitis. The 5-year clinical and radiographic outcomes indicated maintenance of the clinical improvement.

  2. Trends in Surgical Practices for Lateral Epicondylitis Among Newly Trained Orthopaedic Surgeons.

    Science.gov (United States)

    Wang, Dean; Degen, Ryan M; Camp, Christopher L; McGraw, Michael H; Altchek, David W; Dines, Joshua S

    2017-10-01

    Much controversy exists regarding the optimal surgical intervention for lateral epicondylitis because of a multitude of options available and the lack of comparative studies. Knowledge of the current practice trends would help guide the design of comparative studies needed to determine which surgical technique results in the best outcome. To review the latest practice trends for the surgical treatment of lateral epicondylitis among newly trained surgeons in the United States utilizing the American Board of Orthopaedic Surgery (ABOS) database. Cross-sectional study; Level of evidence, 3. The ABOS database was utilized to identify surgical cases for lateral epicondylitis submitted by Part II board certification examination candidates from 2004 through 2013. Inclusion criteria were predetermined using a combination of International Classification of Diseases, Ninth Revision (ICD-9) and Current Procedural Terminology (CPT) codes. Cases were organized by open and arthroscopic treatment groups and by fellowship training and were analyzed to determine differences in surgical techniques, complication rates, and concomitant procedures. In total, 1150 surgeons submitted 2106 surgical cases for the treatment of lateral epicondylitis. The number of surgical cases for lateral epicondylitis performed per 10,000 submitted cases significantly decreased from 26.7 in 2004 to 21.1 in 2013 ( P = .002). Among all cases, 92.2% were open and 7.8% were arthroscopic, with no change in the incidence of arthroscopic surgeries over the study period. Shoulder and elbow (18.1%) and sports medicine (11.4%) surgeons were more likely to perform surgery arthroscopically compared with hand surgeons (6.1%) ( P < .001). There was no difference in overall self-reported complication rates between open (4.4%) and arthroscopic (5.5%) procedures ( P = .666). Percutaneous tenotomy, debridement only, and debridement with tendon repair comprised 6.4%, 46.3%, and 47.3% of open treatment, respectively. Sports

  3. Complex radial folds versus subtle signs of intracapsular rupture of breast implants: MR findings with surgical correlation.

    Science.gov (United States)

    Soo, M S; Kornguth, P J; Walsh, R; Elenberger, C D; Georgiade, G S

    1996-06-01

    Detection of intracapsular rupture of silicone breast prostheses using MR imaging is often performed by identifying the "linguine sign" [1]. The linguine sign is easily differentiated from simple radial folds that are seen in intact implants. However, more subtle signs of intracapsular rupture, including undulating subcapsular lines and the "teardrop sign," are less often recognized [2-5] and may prove difficult for the less experienced radiologist to differentiate from complex radial folds of intact implants. In this essay, we illustrate the MR imaging findings of complex radial folds in intact implants and compare them with findings of incomplete shell collapse in ruptured implants in a surgically confirmed series of explanted silicone breast prostheses.

  4. Adverse effects of nickel in transosseous wires and surgical implants: literature review.

    Science.gov (United States)

    Nwashindi, A; Dim, E M

    2014-01-01

    Transosseous wires used in the management of fractures are stainless steel alloys which contain nickel 14.5%, chromium 17.6%, iron 62.5% and molybdenum 2.8%. Gradual disintegration of the transosseous wires release nickel into the blood leading to increase nickel concentration in the blood. Nickel has been found to have some adverse systemic effects on the body. The aim of this paper is to discuss the sources of Nickel in the body as well as the systemic adverse effects of Nickel as a degradation product of stainless steel surgical implants. A study of pertinent literature on nickel as a content of stainless steel alloy used in implant surgery was done, taking note also of other sources of nickel in the body, the toxicokinetics of nickel and the related adverse effects of this metal and its compound in humans. As outcome,the sources of human exposure to nickel,distribution and metabolism of nickel in the body, host responseto stainless steel wires and the adverse effects of nickel in the body are presented. It may be necessary to discourage the use of wires or implants containing nickel in the management of fractures.The need for removal of these implants after they have served their purposes is emphasized.

  5. Heat generation during implant placement in low-density bone: effect of surgical technique, insertion torque and implant macro design.

    Science.gov (United States)

    Marković, Aleksa; Mišić, Tijana; Miličić, Biljana; Calvo-Guirado, Jose Luis; Aleksić, Zoran; Ðinić, Ana

    2013-07-01

    The study aimed to investigate the effect of surgical technique, implant macrodesign and insertion torque on bone temperature changes during implant placement. In the in vitro study, 144 self-tapping (blueSKY(®) 4 × 10 mm; Bredent) and 144 non-self-tapping (Standard implant(®) 4.1 × 10 mm; Straumann) were placed in osteotomies prepared in pig ribs by lateral bone condensing or bone drilling techniques. The maximum insertion torque values of 30, 35 and 40 Ncm were used. Real-time bone temperature measurement during implant placement was performed by three thermocouples positioned vertically, in tripod configuration around every osteotomy, at a distance of 5 mm from it and at depths of 1, 5 and 10 mm. Data were analysed using Kruskal-Wallis, Mann-Whitney U-tests and Regression analysis. Significant predictor of bone temperature at the osteotomy depth of 1 mm was insertion torque (P = 0.003) and at the depth of 10-mm implant macrodesign (P = 0.029), while no significant predictor at depth of 5 mm was identified (P > 0.05). Higher insertion torque values as well as non-self-tapping implant macrodesign were related to higher temperatures. Implant placement in sites prepared by bone drilling induced significantly higher temperature increase (P = 0.021) compared with bone condensing sites at the depth of 5 mm, while no significant difference was recorded at other depths. Compared with 30 Ncm, insertion torque values of 35 and 40 Ncm produced significantly higher temperature increase (P = 0.005; P = 0.003, respectively) at the depth of 1 mm. There was no significant difference in temperature change induced by 35 and 40 Ncm, neither by implant macrodesign at all investigated depths (P > 0.05). Placement of self-tapping implants with low insertion torque into sites prepared by lateral bone condensing technique might be advantageous in terms of thermal effect on bone. © 2012 John Wiley & Sons A/S.

  6. The surgical viability and radiological monitoring of brain implants of bioactive micro-seeds in an animal model

    Directory of Open Access Journals (Sweden)

    Giane X. O. Silva

    2005-10-01

    Full Text Available The interstitial implant is a therapeutic modality in brachytherapy of the head and neck. Presently, the seeds implanted in tumors in the central nervous system are metallic I-125. After the full emission of the radionuclide, the seed remains inert in the implanted area. Bioactive ceramic seeds have been prepared for this research group incorporating Sm-152 to be active in Sm-153. The main goal of the present study is the development of a the surgical technique for implanting the biodegradable radioactive micro-seeds in the brains of rabbits, as well as the observation of the clinical reactions of the animal after implantation of two sets of three seeds. The surgical procedure consisted of performing two separate perforations 10 mm from each other in the skull, permitting the implantation of two groups of three seeds, totaling six seeds. The results of the pilot study showed the effectiveness of the surgical procedure and of the biocompatibility of the seeds and the lack of presence of adverse reactions, functional sequels, or inflammation in a follow up 50 days post-surgery. Such seeds of reduced volume, 0.2 x 1.6 mm, could be monitored by computerized tomography 30 days after implanting.Os implantes intersticiais podem ser utilizados em braquiterapia de cabeça e pescoço. Atualmente as sementes implantadas no CNS são de I-125 metálicas. Após o decaimento do radioisótopo, a semente fica inerte na região implantada. Sementes cerâmicas bioativas tem sido preparadas pelo grupo de pesquisa incorporando Sm-152. O presente estudo tem o objetivo de viabilizar a técnica cirúrgica de implantes de microsementes biodegradáveis não radioativas no cérebro de coelhos, bem como verificar as reações clínicas e funcionais do animal ao corpo estranho implantado. O procedimento cirúrgico compreendeu em proceder duas perfurações separadas em 10mm na calota craniana onde foi possível a implantação de dois conjuntos de três sementes

  7. High resolution micro-CT scanning as an innovative tool for evaluation of the surgical positioning of cochlear implant electrodes.

    Science.gov (United States)

    Postnov, A; Zarowski, A; De Clerck, N; Vanpoucke, F; Offeciers, F E; Van Dyck, D; Peeters, S

    2006-05-01

    X-ray microtomography (micro-CT) is a new technique allowing for visualization of the internal structure of opaque specimens with a quasi-histological quality. Among multiple potential applications, the use of this technique in otology is very promising. Micro-CT appears to be ideally suited for in vitro visualization of the inner ear tissues as well as for evaluation of the electrode damage and/or surgical insertion trauma during implantation of the cochlear implant electrodes. This technique can greatly aid in design and development of new cochlear implant electrodes and is applicable for temporal bone studies. The main advantage of micro-CT is the practically artefact-free preparation of the samples and the possibility of evaluation of the interesting parameters along the whole insertion depth of the electrode. This paper presents the results of the first application of micro-CT for visualization of the inner ear structures in human temporal bones and for evaluation of the surgical positioning of the cochlear implant electrodes relative to the intracochlear soft tissues.

  8. [Contribution of computer-aided design for the conception of custom-made implants in Pectus Excavatum surgical treatment. Experience of the Nantes plastic surgery unit].

    Science.gov (United States)

    Tilliet Le Dentu, H; Lancien, U; Sellal, O; Duteille, F; Perrot, P

    2018-02-01

    Pectus excavatum is the most common congenital chest malformation and is a common reason for consultation in plastic surgery. Our attitude is most often a filling of the depression with a custom-made silicone prosthesis. The objective of this work was to evaluate the interest of computer-aided design (CAD) of implants compared to the conventional plaster molds method. We have collected all the cases of custom-made silicone implants to treat funnel chests in our plastic surgery department. The quality of the results was evaluated by the patient, and in a blind manner by the surgical team using photographs and standardized surveys. The pre-operative delays, the operating time and length of hospital stays, the number of surgical recoveries, and the post-operative surgical outcomes were recorded. Between 1990 and 2016, we designed 29 silicone thoracic implants in our department. Before 2012, implants were made from plaster chest molds (n=13). After this date, implants were designed by CAD (n=16). Patients rated their results as "good" or "excellent" in 77% and 86% of cases respectively in the plaster and CAD groups. The surgical team's ratings for CAD implant reconstructions were better than in the plaster group: 8.17 versus 6.96 (P=0.001). CAD implants were significantly less detectable than the plaster group implants. The operating time was reduced in the CAO group: 60.2 compared to 74.7minutes in the plaster group (P=0.04), as was the length of hospitalization: 3.5 versus 5.3 days (P=0.01). There were no significant differences between the two groups in terms of post-operative complications. The management of pectus excavatum by a custom-made silicone implant is a minimally invasive method that provides good cosmetic results. The design of these implants is facilitated and qualitatively improved by CAD. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  9. A novel dental implant guided surgery based on integration of surgical template and augmented reality.

    Science.gov (United States)

    Lin, Yen-Kun; Yau, Hong-Tzong; Wang, I-Chung; Zheng, Cheng; Chung, Kwok-Hung

    2015-06-01

    Stereoscopic visualization concept combined with head-mounted displays may increase the accuracy of computer-aided implant surgery. The aim of this study was to develop an augmented reality-based dental implant placement system and evaluate the accuracy of the virtually planned versus the actual prepared implant site created in vitro. Four fully edentulous mandibular and four partially edentulous maxillary duplicated casts were used. Six implants were planned in the mandibular and four in the maxillary casts. A total of 40 osteotomy sites were prepared in the casts using stereolithographic template integrated with augmented reality-based surgical simulation. During the surgery, the dentist could be guided accurately through a head-mounted display by superimposing the virtual auxiliary line and the drill stop. The deviation between planned and prepared positions of the implants was measured via postoperative computer tomography generated scan images. Mean and standard deviation of the discrepancy between planned and prepared sites at the entry point, apex, angle, depth, and lateral locations were 0.50 ± 0.33 mm, 0.96 ± 0.36 mm, 2.70 ± 1.55°, 0.33 ± 0.27 mm, and 0.86 ± 0.34 mm, respectively, for the fully edentulous mandible, and 0.46 ± 0.20 mm, 1.23 ± 0.42 mm, 3.33 ± 1.42°, 0.48 ± 0.37 mm, and 1.1 ± 0.39 mm, respectively, for the partially edentulous maxilla. There was a statistically significant difference in the apical deviation between maxilla and mandible in this surgical simulation (p augmented reality technology. © 2013 Wiley Periodicals, Inc.

  10. Computer-aided design and computer-aided modeling (CAD/CAM) generated surgical splints, cutting guides and custom-made implants: Which indications in orthognathic surgery?

    Science.gov (United States)

    Scolozzi, P

    2015-12-01

    The purpose of the present report was to describe our indications, results and complications of computer-aided design and computer-aided modeling CAD/CAM surgical splints, cutting guides and custom-made implants in orthognathic surgery. We analyzed the clinical and radiological data of ten consecutive patients with dentofacial deformities treated using a CAD/CAM technique. Four patients had surgical splints and cutting guides for correction of maxillomandibular asymmetries, three had surgical cutting guides and customized internal distractors for correction of severe maxillary deficiencies and three had custom-made implants for additional chin contouring and/or mandibular defects following bimaxillary osteotomies and sliding genioplasty. We recorded age, gender, dentofacial deformity, surgical procedure and intra- and postoperative complications. All of the patients had stable cosmetic results with a high rate of patient satisfaction at the 1-year follow-up examination. No intra- and/or postoperative complications were encountered during any of the different steps of the procedure. This study demonstrated that the application of CAD/CAM patient-specific surgical splints, cutting guides and custom-made implants in orthognathic surgery allows for a successful outcome in the ten patients presented in this series. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  11. Complete Surgical Excision Is Essential for the Management of Patients With Breast Implant-Associated Anaplastic Large-Cell Lymphoma.

    Science.gov (United States)

    Clemens, Mark W; Medeiros, L Jeffrey; Butler, Charles E; Hunt, Kelly K; Fanale, Michelle A; Horwitz, Steven; Weisenburger, Dennis D; Liu, Jun; Morgan, Elizabeth A; Kanagal-Shamanna, Rashmi; Parkash, Vinita; Ning, Jing; Sohani, Aliyah R; Ferry, Judith A; Mehta-Shah, Neha; Dogan, Ahmed; Liu, Hui; Thormann, Nora; Di Napoli, Arianna; DiNapoli, Arianna; Lade, Stephen; Piccolini, Jorge; Reyes, Ruben; Williams, Travis; McCarthy, Colleen M; Hanson, Summer E; Nastoupil, Loretta J; Gaur, Rakesh; Oki, Yasuhiro; Young, Ken H; Miranda, Roberto N

    2016-01-10

    Breast implant-associated anaplastic large-cell lymphoma (BI-ALCL) is a rare type of T-cell lymphoma that arises around breast implants. The optimal management of this disease has not been established. The goal of this study is to evaluate the efficacy of different therapies used in patients with BI-ALCL to determine an optimal treatment approach. In this study, we applied strict criteria to pathologic findings, assessed therapies used, and conducted a clinical follow-up of 87 patients with BI-ALCL, including 50 previously reported in the literature and 37 unreported. A Prentice, Williams, and Peterson model was used to assess the rate of events for each therapeutic intervention. The median and mean follow-up times were 45 and 30 months, respectively (range, 3 to 217 months). The median overall survival (OS) time after diagnosis of BI-ALCL was 13 years, and the OS rate was 93% and 89% at 3 and 5 years, respectively. Patients with lymphoma confined by the fibrous capsule surrounding the implant had better event-free survival (EFS) and OS than did patients with lymphoma that had spread beyond the capsule (P = .03). Patients who underwent a complete surgical excision that consisted of total capsulectomy with breast implant removal had better OS (P = .022) and EFS (P = .014) than did patients who received partial capsulectomy, systemic chemotherapy, or radiation therapy. Surgical management with complete surgical excision is essential to achieve optimal EFS in patients with BI-ALCL. © 2015 by American Society of Clinical Oncology.

  12. Fixation of Hydroxyapatite-Coated Revision Implants Is Improved by the Surgical Technique of Cracking the Sclerotic Bone Rim

    Science.gov (United States)

    Elmengaard, Brian; Bechtold, Joan E.; Chen, Xinqian; Søballe, Kjeld

    2013-01-01

    Revision joint replacement has poorer outcomes that have been associated with poorer mechanical fixation. We investigate a new bone-sparing surgical technique that locally cracks the sclerotic bone rim formed during aseptic loosening. We inserted 16 hydroxyapatite-coated implants bilaterally in the distal femur of eight dogs, using a controlled weight-bearing experimental model that replicates important features of a typical revision setting. At 8 weeks, a control revision procedure and a crack revision procedure were performed on contralateral implants. The crack procedure used a splined tool to perform a systematic local perforation of the sclerotic bone rim of the revision cavity. After 4 weeks, the hydroxyapatite-coated implants were evaluated for mechanical fixation by a push-out test and for tissue distribution by histomorphometry. The cracking revision procedure resulted in significantly improved mechanical fixation, significantly more bone ongrowth and bone volume in the gap, and reduced fibrous tissue compared to the control revision procedure. The study demonstrates that the sclerotic bone rim prevents bone ingrowth and promotes fixation by fibrous tissue. The effect of the cracking technique may be due to improved access to the vascular compartment of the bone. The cracking technique is a simple surgical method that potentially can improve the fixation of revision implants in sclerotic regions important for obtaining the fixation critical for overall implant stability. PMID:19148940

  13. In-vitro study on the accuracy of a simple-design CT-guided stent for dental implants

    International Nuclear Information System (INIS)

    Huh, Young June; Choi, Bo Ram; Huh, Kyung Hoe; Yi, Won Jin; Heo, Min Suk; Lee, Sam Sun; Choi, Soon Chul

    2012-01-01

    An individual surgical stent fabricated from computed tomography (CT) data, called a CT-guided stent, would be useful for accurate installation of implants. The purpose of the present study was to introduce a newly developed CT-guided stent with a simple design and evaluate the accuracy of the stent placement. A resin template was fabricated from a hog mandible and a specially designed plastic plate, with 4 metal balls inserted in it for radiographic recognition, was attached to the occlusal surface of the template. With the surgical stent applied, CT images were taken, and virtual implants were placed using software. The spatial positions of the virtually positioned implants were acquired and implant guiding holes were drilled into the surgical stent using a specially designed 5-axis drilling machine. The surgical stent was placed on the mandible and CT images were taken again. The discrepancy between the central axis of the drilled holes on the second CT images and the virtually installed implants on the first CT images was evaluated. The deviation of the entry point and angulation of the central axis in the reference plane were 0.47±0.27 mm, 0.57±0.23 mm, and 0.64±0.16 degree, 0.57±0.15 degree, respectively. However, for the two different angulations in each group, the 20 degree angulation showed a greater error in the deviation of the entry point than did the 10 degree angulation. The CT-guided template proposed in this study was highly accurate. It could replace existing implant guide systems to reduce costs and effort.

  14. Short Implants: New Horizon in Implant Dentistry.

    Science.gov (United States)

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  15. Non-surgical periodontal treatment of peri-implant diseases with the adjunctive use of diode laser: preliminary clinical study.

    Science.gov (United States)

    Lerario, Francesco; Roncati, Marisa; Gariffo, Annalisa; Attorresi, Enrica; Lucchese, Alessandra; Galanakis, Alexandros; Palaia, Gaspare; Romeo, Umberto

    2016-01-01

    Peri-implant diseases present in two forms: peri-implant mucositis and peri-implantitis. The prevalence of peri-implant complications is significantly rising. The aim of this study was to compare conventional treatment of inflamed peri-implant tissues with conventional treatment together with diode laser application. Twenty-seven patients (age 36 to 67, 15 women and 12 men, 12 smokers and 15 non-smokers) requiring treatment for mucositis or peri-implantitis were taken into account for this preliminary study. Plaque index (PI), pocket depth (PD), and bleeding on probing (BoP) were recorded at baseline evaluation. Patients in control group (CG) received conventional non-surgical periodontal treatment. Patients in test group received conventional non-surgical periodontal treatment together with diode laser application (810 nm, 30 s, 1 W, 50 Hz, t on = 100 ms, t off = 100 ms, energy density = 24.87 J/cm(2)). Paired t test was used to evaluate the difference in repeated measurements of considered indexes at T 0 and T 1 (1 year) in both groups. A total of 606 sites were taken into account in the test group (TG) and 144 in the CG. PD mean variation in the TG was 2.66 mm ± 1.07, while mean PD variation in the CG was 0.94 ± 1.13 mm. Paired t testing of the variation in PD in CG and TG revealed a statistically significant difference between the two groups (p diode laser seems to be an additional valuable tool for peri-implant disease treatment.

  16. Urogynecologic Surgical Mesh Implants

    Science.gov (United States)

    ... procedures performed to treat pelvic floor disorders with surgical mesh: Transvaginal mesh to treat POP Transabdominal mesh to treat ... address safety risks Final Order for Reclassification of Surgical Mesh for Transvaginal Pelvic Organ Prolapse Repair Final Order for Effective ...

  17. Improving osseointegration of dental implants.

    Science.gov (United States)

    Elias, Carlos Nelson; Meirelles, Luiz

    2010-03-01

    In the beginning of implantology, the procedures adopted for treating patients were performed in two surgical phases with an interval of 3-6 months. Nowadays, it is possible to insert and load a dental implant in the same surgical procedure. This change is due to several factors, such as improvement of surgical technique, modifications of the implant design, increased quality of implant manufacturing, development of the surgical instruments' quality, careful patient screening and adequate treatment of the implant surface. The clinical results show that adequate treatment of surfaces is crucial for reducing healing time and treating at-risk patients. The surface properties of dental implants can be significantly improved at the manufacturing stage, affecting cells' activity during the healing phase that will ultimately determine the host tissue response, a fundamental requirement for clinical success. This review focuses on different types of dental implant surfaces and the influence of surface characteristics on osseointegration.

  18. Surgical site infections following transcatheter apical aortic valve implantation: incidence and management.

    Science.gov (United States)

    Baillot, Richard; Fréchette, Éric; Cloutier, Daniel; Rodès-Cabau, Josep; Doyle, Daniel; Charbonneau, Éric; Mohammadi, Siamak; Dumont, Éric

    2012-11-13

    The present study was undertaken to examine the incidence and management of surgical site infection (SSI) in patients submitted to transapical transcatheter aortic valve implantation (TA-TAVI). From April 2007 to December 2011, 154 patients underwent TA-TAVI with an Edwards Sapien bioprosthesis (ES) at the Institut Universitaire de Cardiologie et Pneumologie de Québec (IUCPQ) as part of a multidisciplinary program to prospectively evaluate percutaneous aortic valve implantation. Patient demographics, perioperative variables, and postoperative complications were recorded in a prospective registry. Five (3.2%) patients in the cohort presented with an SSI during the study period. The infections were all hospital-acquired (HAI) and were considered as organ/space SSI's based on Center for Disease Control criteria (CDC). Within the first few weeks of the initial procedure, these patients presented with an abscess or chronic draining sinus in the left thoracotomy incision and were re-operated. The infection spread to the apex of the left ventricle in all cases where pledgeted mattress sutures could be seen during debridement. Patients received multiple antibiotic regimens without success until the wound was surgically debrided and covered with viable tissue. The greater omentum was used in three patients and the pectoralis major muscle in the other two. None of the patients died or had a recurrent infection. Three of the patients were infected with Staphylococcus epidermidis, one with Staphylococcus aureus, and one with Enterobacter cloacae. Patients with surgical site infections were significantly more obese with higher BMI (31.4±3.1 vs 26.2±4.4 p=0.0099) than the other patients in the cohort. While TA-TAVI is a minimally invasive technique, SSIs, which are associated with obesity, remain a concern. Debridement and rib resection followed by wound coverage with the greater omentum and/or the pectoralis major muscle were used successfully in these patients.

  19. Cochlear implants in children implanted in Jordan: A parental overview.

    Science.gov (United States)

    Alkhamra, Rana A

    2015-07-01

    Exploring the perspective of parents on the cochlear implant process in Jordan. Sixty parents of deaf children were surveyed on the information gathering process prior to cochlear implant surgery, and their implant outcome expectations post-surgery. Whether child or parent characteristics may impact parents' post-surgical expectations was explored. Although parents used a variety of information sources when considering a cochlear implant, the ear, nose and throat doctor comprised their major source of information (60%). Parents received a range of information prior to cochlear implant but agreed (93.3%) on the need for a multidisciplinary team approach. Post-surgically, parents' expected major developments in the areas of spoken language (97%), and auditory skills (100%). Receiving education in mainstream schools (92%) was expected too. Parents perceived the cochlear implant decision as the best decision they can make for their child (98.3%). A significant correlation was found between parents contentment with the cochlear implant decision and expecting developments in the area of reading and writing (r=0.7). Child's age at implantation and age at hearing loss diagnosis significantly affected parents' post-implant outcome expectations (pparents agree on the need for a comprehensive multidisciplinary team approach during the different stages of the cochlear implant process. Parents' education about cochlear implants prior to the surgery can affect their post-surgical outcome expectations. The parental perspective presented in this study can help professionals develop better understanding of parents' needs and expectations and henceforth improve their services and support during the different stages of the cochlear implant process. Copyright © 2015. Published by Elsevier Ireland Ltd.

  20. The utilization of a diode laser in the surgical treatment of peri-implantitis. A randomized clinical trial.

    Science.gov (United States)

    Papadopoulos, Christos A; Vouros, Ioannis; Menexes, Georgios; Konstantinidis, Antonis

    2015-11-01

    A comparison of different treatment modalities of peri-implantitis can lead to the development and application of more effective and efficient methods of therapy in clinical practice. This study compares the effectiveness of open flap debridement used alone, with an approach employing the additional use of a diode laser for the treatment of peri-implantitis. Nineteen patients were divided into two groups and treated for peri-implantitis. In the control group (C group), the therapy utilized access flaps, plastic curettes, and sterilized gauzes soaked in saline. The test group (L group) was treated similarly but with additional irradiation using a diode laser. The parameters studied were pocket depth (PD) as the primary outcome variable, clinical attachment level (CAL), bleeding on probing (BOP), and plaque index (PI) as secondary variables. Measurements were performed at three different time points, baseline (BSL), 3 months, and 6 months after treatment. Three months after treatment, a mean PD reduction of 1.19 mm for the control group and 1.38 mm for the laser group was recorded. The corresponding BOP changes were 72.9 and 66.7%, respectively. These changes were significant and remained at the same levels at the 6-month examination (p Surgical treatment of peri-implantitis by access flaps leads to improvement of all clinical parameters studied while the additional use of diode laser does not seem to have an extra beneficiary effect. The additional use of a diode laser in the surgical treatment of peri-implantitis offers a limited clinical benefit.

  1. Surgical Results of Trabeculectomy and Ahmed Valve Implantation Following a Previous Failed Trabeculectomy in Primary Congenital Glaucoma Patients

    OpenAIRE

    Lee, Naeun; Ma, Kyoung Tak; Bae, Hyoung Won; Hong, Samin; Seong, Gong Je; Hong, Young Jae; Kim, Chan Yun

    2015-01-01

    Purpose To compare the surgical results of trabeculectomy and Ahmed glaucoma valve implantation after a previous failed trabeculectomy. Methods A retrospective comparative case series review was performed on 31 eye surgeries in 20 patients with primary congenital glaucoma who underwent trabeculectomy or Ahmed glaucoma valve implantation after a previous failed trabeculectomy with mitomycin C. Results The preoperative mean intraocular pressure was 25.5 mmHg in the trabeculectomy group and 26.9...

  2. Angioplasty treatment and stent implant vs. surgical treatment in patients with stenosis of the cervical carotid artery

    International Nuclear Information System (INIS)

    Hamdan, Nabil; Castro, Pablo; Calderon, Luis I; Gomez, German; Estrada, Gilberto; Hurtado, Edgar; Echeverria, Rene

    2006-01-01

    Angioplasty with stent implant is a less invasive procedure than surgical intervention in the treatment of significant stenosis of the common cervical carotid artery (common and internal) (5). Currently the major published studies, in which angioplasty and surgical treatment are compared, show similar results in the major events, as cerebrovascular accidents and mortality, but a greater significant difference in the apparition of acute myocardial infarction, during surgical intervention (5,11). The objective of this study is to compare in both treatment methods the major and minor clinical events, like cerebrovascular accident, acute myocardial infarction, death, bradycardia, hypotension and encephalopathy during the intervention, the hospitalization and the follow-up year, as well as the re-intervention, the time of hospital stay and the complications of the surgical incision. Materials and methods: in this study of historical cohort, 46 patients with significant stenosis of the cervical carotid arteries, who were subjected to intervention from January 1st 2001 to December 31st 2003, were included. 21 patients were treated with angioplasty and stent implant and 25 with surgery (endarterectomy) Results: 1 (4.8%) major cerebrovascular accident occurred during angioplasty, whereas none occurred in the patients treated with surgery. 1 (4%) acute myocardial infarction occurred during intervention in the group of patients treated with surgery, and none in the patients treated with angioplasty. No deaths occurred in any of the groups during intervention, hospitalization and the follow-up year. After 8 months 1 (4%) patient treated with surgery was intervened again with angioplasty and stent implant. There were no statistically significant differences between both groups during hospitalization, and in the apparition of minor complications as bradycardia and hypotension. 2 (8%) complications related to the incision of the neck compromising cranial nerves, occurred in the

  3. Fixation of revision implants is improved by a surgical technique to crack the sclerotic bone rim.

    Science.gov (United States)

    Kold, Søren; Bechtold, Joan E; Mouzin, Olivier; Elmengaard, Brian; Chen, Xinqian; Søballe, Kjeld

    2005-03-01

    Revision joint replacement has poorer outcomes compared with primary joint replacement, and these poor outcomes have been associated with poorer fixation. We investigated a surgical technique done during the revision operation to improve access from the marrow space to the implant interface by locally cracking the sclerotic bone rim that forms during aseptic loosening. Sixteen implants were inserted bilaterally by distal femur articulation of the knee joint of eight dogs, using our controlled experimental model that replicates the revision setting (sclerotic bone rim, dense fibrous tissue, macrophages, elevated cytokines) by pistoning a loaded 6.0-mm implant 500 microm into the distal femur with particulate PE. At 8 weeks, one of two revision procedures was done. Both revision procedures included complete removal of the membrane, scraping, lavaging, and inserting a revision plasma-spray Ti implant. The crack revision procedure also used a splined tool to circumferentially locally perforate the sclerotic bone rim before insertion of an identical revision implant. Superior fixation was achieved with the cracking procedure in this experimental model. Revision implants inserted with the rim cracking procedure had a significantly higher pushout strength (fivefold median increase) and energy to failure (sixfold median increase), compared with the control revision procedure. Additional evaluation is needed of local perforation of sclerotic bone rim as a simple bone-sparing means to improve revision implant fixation and thereby increase revision implant longevity.

  4. SU-F-T-03: Radiobiological Evaluation of a Directional Brachytherapy Device Surgically Implanted Following EBRT

    Energy Technology Data Exchange (ETDEWEB)

    Rivard, MJ [Tufts University School of Medicine, Boston, MA (United States); Emrich, JG; Poli, J [Drexel University College of Medicine, Philadelphia, PA (United States)

    2016-06-15

    Purpose: Preceding surgical implantation following external-beam radiotherapy (EBRT) delivery, a radiobiological evaluation was performed for a new LDR Pd-103 directional brachytherapy device (CivaSheet). As this was the first case with the device used in combination with EBRT, there was concern to determine the appropriate prescription dose. Methods: The radiobiological model of Dale (1985, 1989) was used for a permanent LDR implant including radioactive decay. The biological effective dose (BED) was converted to the equivalent dose in 2 Gy fractions (EQD2) for comparison with EBRT prescription expectations. Given IMRT delivery of 50.4 Gy, an LDR brachytherapy dose of approximately 15–20 Gy EQD2 was desired. To be specific to the treatment site (leiomyosarcoma T2bN0M0, grade 2 with R1 surgical margin), the radiobiological model required several radiobiological parameters with values taken from the literature. A sensitivity analysis was performed to determine their relative importance on the calculated BED and subsequent EQD2. The Pd-103 decay constant (λ=0.0017 h{sup −1}) was also used. DVHs were prepared for pre- and post-surgical geometries to glean the possible and realized implant geometric configuration. DVHs prepared in VariSeed9 were converted to BEDVHs and subsequently EQD2 values for each volume-element. Results: For a physical dose of 28 Gy to a 0.5 cm depth, BED=21.7 Gy and EQD2=17.6 Gy, which was near the center of the desired EQD2 range. Tumor bed (CTV=4 cm{sup 3}) coverage was 99.2% with 48 sources implanted. In order of decreasing importance from the sensitivity analysis, the radiobiological parameters were α=0.25 Gy{sup −1}, T{sub POT}=23 days, α/β=8.6 Gy, and T=1.5 h. Percentage variations in these values produced EQD2 variations of 40%, 20%, 18%, and 1%, respectively. Conclusion: This radiobiological evaluation indicated that prescription dose may be determined for comparison with the desired EQD2, and that radiobiologicalparameter

  5. Vascular mapping of the retroauricular skin - proposal for a posterior superior surgical incision for transcutaneous bone-conduction hearing implants.

    Science.gov (United States)

    Perenyi, Adam; Bere, Zsofia; Jarabin, Janos; Sztano, Balazs; Kukla, Edit; Bikhazi, Ziad; Tiszlavicz, Laszlo; Toth, Ferenc; Kiss, Jozsef Geza; Rovo, Laszlo

    2017-01-17

    Passive transcutaneous osseointegrated hearing implant systems have become increasingly popular more recently. The area over the implant is vulnerable due to vibration and pressure from the externally worn sound processor. Good perfusion and neural integrity has the potential to reduce complications. The authors' objective was to determine the ideal surgical exposure to maintain perfusion and neural integrity and decrease surgical time as a result of reduced bleeding. The vascular anatomy of the temporal-parietal soft tissue was examined in a total of 50 subjects. Imaging diagnostics included magnetic resonance angiography in 12 and Doppler ultrasound in 25 healthy subjects to reveal the arterial network. Cadaver dissection of 13 subjects formed the control group. The prevalence of the arteries were statistically analyzed with sector analysis in the surgically relevant area. The main arterial branches of this region could be well identified with each method. Statistical analysis showed that the arterial pattern was similar in all subjects. The prevalence of major arteries is low in the upper posterior area though large in proximity to the auricle region. Diverse methods indicate the advantages of a posterior superior incision because the major arteries and nerves are at less risk of damage and best preserved. Although injury to these structures is rare, when it occurs, the distal flow is compromised and the peri-implant area is left intact. Hand-held Doppler is efficient and cost-effective in finding the best position for incision, if necessary, in subjects with a history of surgical stress to the retroauricular skin. This was a non-interventional study.

  6. Determine the Influence of Time Held in “Knockdown” Anesthesia on Survival and Stress of Surgically Implanted Juvenile Salmonids

    Energy Technology Data Exchange (ETDEWEB)

    Woodley, Christa M.; Wagner, Katie A.; Knox, Kasey M.

    2012-01-31

    The Juvenile Salmon Acoustic Telemetry System (JSATS) was developed for the U.S. Army Corp of Engineers Portland District (USACE) to address questions related to survival and performance measures of juvenile salmonids as they pass through the Federal Columbia River Power System (FCRPS). Researchers using JSATS acoustic transmitters (ATs) were tasked with standardizing the surgical implantation procedure to ensure that the stressors of handling and surgery on salmonids were consistent and less likely to cause effects of tagging in survival studies. Researchers questioned whether the exposure time in 'knockdown' anesthesia (or induction) to prepare fish for surgery could influence the survival of study fish (CBSPSC 2011). Currently, fish are held in knockdown anesthesia after they reach Stage 4 anesthesia until the completion of the surgical implantation of a transmitter, varies from 5 to 15 minutes for studies conducted in the Columbia Basin. The Columbia Basin Surgical Protocol Steering Committee (CBSPSC ) expressed concern that its currently recommended 10-minute maximum time limit during which fish are held in anesthetic - tricaine methanesulfonate (MS-222, 80 mg L-1 water) - could increase behavioral and physiological costs, and/or decrease survival of outmigrating juvenile salmonids. In addition, the variability in the time fish are held at Stage 4 could affect the data intended for direct comparison of fish within or among survival studies. Under the current recommended protocol, if fish exceed the 10-minute time limit, they are to be released without surgical implantation, thereby increasing the number of fish handled and endangered species 'take' at the bypass systems for FCRPS survival studies.

  7. Surgical implantation of temperature-sensitive transmitters and data-loggers to record body temperature in koalas (Phascolarctos cinereus).

    Science.gov (United States)

    Adam, D; Johnston, S D; Beard, L; Nicholson, V; Lisle, A; Gaughan, J; Larkin, R; Theilemann, P; Mckinnon, A; Ellis, W

    2016-01-01

    Under predicted climate change scenarios, koala distribution in Australia is expected to be adversely affected. Recent studies have attempted to identify suitable habitat, based on models of bioclimatic regions, but to more accurately reflect the thermal tolerance and behavioural adaptations of the various regional populations, the koala's response to periods of heat stress will need to be investigated at the individual animal level. To explore the safety and suitability of temperature-sensitive intra-abdominal implants for monitoring core body temperature in the koala. A temperature-sensitive radio transmitter and thermal iButton data-logger, waxed together as a package, were surgically implanted into the abdominal cavity of four captive koalas. In one animal the implant was tethered and in the other three, it was left free-floating. After 3 months, the implants were removed and all four koalas recovered without complications. The tethering of the package in the one koala resulted in minor inflammation and adhesion, so this practice was subsequently abandoned. The free-floating deployments were complication-free and revealed a diurnal body temperature rhythm, with daily ranges of 0.4-2.8°C. The minimum recorded body temperature was 34.2°C and the maximum was 37.7°C. The difference in the readings obtained from the transmitters and iButtons never exceeded 0.3°C. The suitability of the surgical approach was confirmed, from both the animal welfare and data collection points of view. © 2016 Australian Veterinary Association.

  8. When operable patients become inoperable: conversion of a surgical aortic valve replacement into transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Arendrup, Henrik; Engstrøm, Thomas

    2009-01-01

    . On extracorporal circulation it was reconized that the aortic annulus, the coronary ostiae and the proximal part of the ascending aorta were severely calcified making valve implantation impossible. Surgical closure without valve substitution was estimated to be associated with a high risk of mortality due...

  9. Location of unaccessible implant surface areas during debridement in simulated peri-implantitis therapy

    OpenAIRE

    Steiger-Ronay, Valerie; Merlini, Andrea; Wiedemeier, Daniel B.; Schmidlin, Patrick R.; Attin, Thomas; Sahrmann, Philipp

    2017-01-01

    Background An in vitro model for peri-implantitis treatment was used to identify areas that are clinically difficult to clean by analyzing the pattern of residual stain after debridement with commonly employed instruments. Methods Original data from two previous publications, which simulated surgical (SA) and non-surgical (NSA) implant debridement on two different implant systems respectively, were reanalyzed regarding the localization pattern of residual stains after instrumentation. Two bli...

  10. Training considerations for the intracoelomic implantation of electronic tags in fish with a summary of common surgical errors

    Energy Technology Data Exchange (ETDEWEB)

    Cooke, Steven J.; Wagner, Glenn N.; Brown, Richard S.; Deters, Katherine A.

    2011-01-01

    Training is a fundamental part of all scientific and technical disciplines. This is particularly true for all types of surgeons. For surgical procedures, a number of skills are necessary to reduce mistakes. Trainees must learn an extensive yet standardized set of problem-solving and technical skills to handle challenges as they arise. There are currently no guidelines or consistent training methods for those intending to implant electronic tags in fish; this is surprising, considering documented cases of negative consequences of fish surgeries and information from studies having empirically tested fish surgical techniques. Learning how to do fish surgery once is insufficient for ensuring the maintenance or improvement of surgical skill. Assessment of surgical skills is rarely incorporated into training, and is needed. Evaluation provides useful feedback that guides future learning, fosters habits of self-reflection and self-remediation, and promotes access to advanced training. Veterinary professionals should be involved in aspects of training to monitor basic surgical principles. We identified attributes related to knowledge, understanding, and skill that surgeons must demonstrate prior to performing fish surgery including a “hands-on” assessment using live fish. Included is a summary of common problems encountered by fish surgeons. We conclude by presenting core competencies that should be required as well as outlining a 3-day curriculum for training surgeons to conduct intracoelomic implantation of electronic tags. This curriculum could be offered through professional fisheries societies as professional development courses.

  11. Cochlear implantation in Pendred syndrome and non-syndromic enlarged vestibular aqueduct – clinical challenges, surgical results, and complications

    DEFF Research Database (Denmark)

    Mey, Kristianna; Bille, Michael; Cayé-Thomasen, Per

    2016-01-01

    , and post-operative complications were retrieved. RESULTS: Complications occurred in 36% of implantations; 5% hereof major complications. Gushing/oozing from the cochleostoma occurred in 10% of implantations and was related to transient, but not prolonged post-operative vertigo. CONCLUSION: Intra......-operative risks of gushing/oozing and post-operative vertigo are the primary clinical issues in PS/NSEVA patients regarding CI. Nonetheless, the surgical success rate is high and the major complication rate is low; similar to studies of unselected series of CI recipients....

  12. Endometrial fluid associated with Essure implants placed before in vitro fertilization: Considerations for patient counseling and surgical management.

    Science.gov (United States)

    Sills, E Scott; Walsh, David J; Jones, Christopher A; Wood, Samuel H

    2015-09-01

    Essure (Bayer) received approval from the U.S. Food and Drugs Administration as a permanent non-hormonal contraceptive implant in November 2002. While the use of Essure in the management of hydrosalpinx prior to in vitro fertilization (IVF) remains off-label, it has been used specifically for this purpose since at least 2007. Although most published reports on Essure placement before IVF have been reassuring, clinical experience remains limited, and no randomized studies have demonstrated the safety or efficacy of Essure in this context. In fact, no published guidelines deal with patient selection or counseling regarding the Essure procedure specifically in the context of IVF. Although Essure is an irreversible birth control option, some patients request the surgical removal of the implants for various reasons. While these patients could eventually undergo hysterectomy, at present no standardized technique exists for simple Essure removal with conservation of the uterus. This article emphasizes new aspects of the Essure procedure, as we describe the first known association between the placement of Essure implants and the subsequent development of fluid within the uterine cavity, which resolved after the surgical removal of both devices.

  13. Cochlear implantation in X-linked deafness - How to manage the surgical challenges.

    Science.gov (United States)

    Saeed, Haroon; Powell, Harry R F; Saeed, Shakeel R

    2016-07-01

    In children with X-linked deafness, cochlear malformations challenge the implant surgeon to avoid electrode insertion into the internal auditory meatus and prevent a continuous cerebrospinal fluid (CSF) leak. We describe our experience of cochlear implantation (CI) in two children with profound hearing loss secondary to X-linked deafness, highlighting safer operative techniques to avoid potential complications. Descriptive cases of two children with X-linked deafness (patient 1 and patient 2) undergoing CI. Peri-operative imaging and work-up to surgery are discussed. Specific operative considerations, post-operative complications and subsequent audiological performance are highlighted. In each case, intra-operative fluoroscopic imaging ensured intra-cochlear insertion of electrodes. Expected CSF gusher was seen in each case which was initially controlled by packing around the cochleostomy and array with temporalis muscle and fascia. Patient 1 developed post-operative meningitis secondary to continuous CSF leak. We avoided further significant CSF leak by planning staged procedures for patient 2, with obliteration of the middle ear cleft and external ear canal (EAC) at the time of implantation. In both patients, bilateral implantation successfully provided hearing thresholds of less than 35 dB in both ears at routine follow up. When planning for CI in children with radiological features of X-linked deafness, intra-operative imaging should be utilized to ensure correct electrode positioning. Traditional methods of stopping a CSF gusher may not suffice. We therefore encourage additional surgical obliteration of the middle ear space and EAC to avoid persistent CSF leak and its associated complications.

  14. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique.

    Science.gov (United States)

    Canut Jordana, M Isabel; Pérez Formigó, Daniel; Abreu González, Rodrigo; Nadal Reus, Jeroni

    2010-11-11

    We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact. Complete ophthalmologic examination and optical coherence tomography (OCT) of the anterior segment were performed. Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control. Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.

  15. Surgical site infections following transcatheter apical aortic valve implantation: incidence and management

    Directory of Open Access Journals (Sweden)

    Baillot Richard

    2012-11-01

    Full Text Available Abstract Objective The present study was undertaken to examine the incidence and management of surgical site infection (SSI in patients submitted to transapical transcatheter aortic valve implantation (TA-TAVI. Methods From April 2007 to December 2011, 154 patients underwent TA-TAVI with an Edwards Sapien bioprosthesis (ES at the Institut Universitaire de Cardiologie et Pneumologie de Québec (IUCPQ as part of a multidisciplinary program to prospectively evaluate percutaneous aortic valve implantation. Patient demographics, perioperative variables, and postoperative complications were recorded in a prospective registry. Results Five (3.2% patients in the cohort presented with an SSI during the study period. The infections were all hospital-acquired (HAI and were considered as organ/space SSI’s based on Center for Disease Control criteria (CDC. Within the first few weeks of the initial procedure, these patients presented with an abscess or chronic draining sinus in the left thoracotomy incision and were re-operated. The infection spread to the apex of the left ventricle in all cases where pledgeted mattress sutures could be seen during debridement. Patients received multiple antibiotic regimens without success until the wound was surgically debrided and covered with viable tissue. The greater omentum was used in three patients and the pectoralis major muscle in the other two. None of the patients died or had a recurrent infection. Three of the patients were infected with Staphylococcus epidermidis, one with Staphylococcus aureus, and one with Enterobacter cloacae. Patients with surgical site infections were significantly more obese with higher BMI (31.4±3.1 vs 26.2±4.4 p=0.0099 than the other patients in the cohort. Conclusions While TA-TAVI is a minimally invasive technique, SSIs, which are associated with obesity, remain a concern. Debridement and rib resection followed by wound coverage with the greater omentum and/or the pectoralis major

  16. Reposição cirúrgico-ortopédica de implante mal posicionado: relato de caso Surgical-orthopedic repositioning of malpositioned implant: a case report

    Directory of Open Access Journals (Sweden)

    Luiz Carlos Ferreira da Silva

    2005-06-01

    Full Text Available A reabilitação bucal por meio da colocação de implantes dentários tem se tornado um procedimento freqüente da clínica odontológica. Falhas no planejamento ou na execução da técnica podem levar a casos onde, apesar de osseointegrado, o implante não apresenta condições de restauração satisfatória devido ao seu mal posicionamento. Diversos autores têm relatado a possibilidade de se utilizar osteotomias segmentares de maxila ou mandíbula para reposicionar um segmento alveolar com implante, mostrando que esta pode ser uma técnica efetiva e previsível para restaurar implantes em posição anatômica comprometida. O presente trabalho apresenta o caso clínico de uma paciente de 20 anos de idade onde foi realizada osteotomia segmentar de maxila associada à distração osteogênica para correção de um implante mal posicionado.Oral rehabilitation through dental implants has become a common procedure at dental practice. However, if the implant is placed in an inappropriate position either because of inadequate presurgical planning or poor surgical technique, it may be unrestorable in spite of osseointegrated. Many authors have reported the possibility of using segmental maxillary or mandibular osteotomies to reposition an alveolar segment with its implants. This can be an effective, predictable technique for restoring implants in a compromised anatomic position. This paper presents a case report describing the use of this procedure associated to distraction osteogeneis to reposition one malpositioned implant in a 20 years old girl.

  17. Surgical Templates for Dental Implant Positioning; Current ...

    African Journals Online (AJOL)

    Since the mid‑20th century, there has been an increase in interest in the implant process for the replacement of missing teeth. Branemark ... Ideal placement of the implant facilitates the establishment of favorable forces on the implants and the prosthetic component as well as ensures an aesthetic outcome. Therefore, it is ...

  18. Implant decontamination with phosphoric acid during surgical peri-implantitis treatment : a RCT

    NARCIS (Netherlands)

    Hentenaar, Diederik F M; De Waal, Yvonne C M; Strooker, Hans; Meijer, Henny J A; Van Winkelhoff, Arie-Jan; Raghoebar, Gerry M

    2017-01-01

    BACKGROUND: Peri-implantitis is known as an infectious disease that affects the peri-implant soft and hard tissue. Today, scientific literature provides very little evidence for an effective intervention protocol for treatment of peri-implantitis. The aim of the present randomized controlled trial

  19. A surgical robot with augmented reality visualization for stereoelectroencephalography electrode implantation.

    Science.gov (United States)

    Zeng, Bowei; Meng, Fanle; Ding, Hui; Wang, Guangzhi

    2017-08-01

    Using existing stereoelectroencephalography (SEEG) electrode implantation surgical robot systems, it is difficult to intuitively validate registration accuracy and display the electrode entry points (EPs) and the anatomical structure around the electrode trajectories in the patient space to the surgeon. This paper proposes a prototype system that can realize video see-through augmented reality (VAR) and spatial augmented reality (SAR) for SEEG implantation. The system helps the surgeon quickly and intuitively confirm the registration accuracy, locate EPs and visualize the internal anatomical structure in the image space and patient space. We designed and developed a projector-camera system (PCS) attached to the distal flange of a robot arm. First, system calibration is performed. Second, the PCS is used to obtain the point clouds of the surface of the patient's head, which are utilized for patient-to-image registration. Finally, VAR is produced by merging the real-time video of the patient and the preoperative three-dimensional (3D) operational planning model. In addition, SAR is implemented by projecting the planning electrode trajectories and local anatomical structure onto the patient's scalp. The error of registration, the electrode EPs and the target points are evaluated on a phantom. The fiducial registration error is [Formula: see text] mm (max 1.22 mm), and the target registration error is [Formula: see text] mm (max 1.18 mm). The projection overlay error is [Formula: see text] mm, and the TP error after the pre-warped projection is [Formula: see text] mm. The TP error caused by a surgeon's viewpoint deviation is also evaluated. The presented system can help surgeons quickly verify registration accuracy during SEEG procedures and can provide accurate EP locations and internal structural information to the surgeon. With more intuitive surgical information, the surgeon may have more confidence and be able to perform surgeries with better outcomes.

  20. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study.

    NARCIS (Netherlands)

    Tabassum, A.; Meijer, G.J.; Wolke, J.G.C.; Jansen, J.A.

    2010-01-01

    OBJECTIVE: The aim of this biomechanical study was to assess the interrelated effect of both surface roughness and surgical technique on the primary stability of dental implants. MATERIAL AND METHODS: For the experiment, 160 screw-designed implants (Biocomp), with either a machined or an etched

  1. Comparison of surface modified zirconia implants with commercially available zirconium and titanium implants: a histological study in pigs.

    Science.gov (United States)

    Gredes, Tomasz; Kubasiewicz-Ross, Pawel; Gedrange, Tomasz; Dominiak, Marzena; Kunert-Keil, Christiane

    2014-08-01

    New biomaterials and their various surface modifications should undergo in vitro and in vivo evaluation before clinical trials. The objective of our in vivo study was to evaluate the biocompatibility of newly created zirconium implant surfaces after implantation in the lower jaw of pigs and compare the osseointegration of these dental implants with commercially available zirconium and titanium implants. After a healing period of 12 weeks, a histological analysis of the soft and hard tissues and a histomorphometric analysis of the bone-implant contact (BIC) were performed. The implant surfaces showed an intimate connection to the adjacent bone for all tested implants. The 3 newly created zirconium implant surfaces achieved a BIC of 45% on average in comparison with a BIC of 56% from the reference zirconium implants and 35% from titanium implants. Furthermore, the new zirconium implants had a better attachment to gingival and bone tissues in the range of implant necks as compared with the reference implants. The results suggest that the new implants comparably osseointegrate within the healing period, and they have a good in vivo biocompatibility.

  2. Multicentre prospective evaluation of implant-assisted mandibular removable partial dentures: surgical and prosthodontic outcomes.

    Science.gov (United States)

    Payne, Alan G T; Tawse-Smith, Andrew; Wismeijer, Daniel; De Silva, Rohana K; Ma, Sunyoung

    2017-01-01

    To determine implant survival and prosthodontic maintenance of implant-assisted mandibular removable partial dentures in a multicentre prospective study up to 10 years. Forty-eight participants with mandibular distal extension partial dentures were selected. A control group of 12 New Zealand participants had new conventional mandibular partial dentures made. Three test groups of 36 participants in New Zealand (n = 12), the Netherlands (n = 12) and Colombia (n = 12) had bilateral distal implants placed. Surgical and prosthodontic outcomes were documented with only healing caps placed (Stage 1) and with an attachment system (Stage 2). No implants failed after 3 years. Four late implant failures in three participants occurred in New Zealand (two unilateral implant failures after 5 and 8 years and two bilateral implant failures in the same participant after 6 and 10 years); two unilateral late implant failures occurred in the Netherlands and no late failures in Colombia. Implant survival rate was 92% by 10 years. Resonance frequency measurements were taken at surgery implant stability quotient (ISQ) 62.44 ± 7.46; range 40 - 79), baseline (ISQ 63.22 ± 6.17; range 50 - 74) and after 3 years (ISQ 66.38 ± 6.77; range 55 - 83). In New Zealand and Colombia, measured crestal bone levels were 2.03 ± 0.71 mm and 2.20 ± 0.81 mm, respectively, at baseline and 3 years. For Stage I, principal prosthodontic maintenance issues were loose healing caps among 10 New Zealand participants, four Colombian participants and one Netherlands participant. For Stage 2, matrix activation and overdenture puncture fractures resulted in 41 events (25 participants) in New Zealand over 10 years, whilst over 3 years, there were 14 events in nine Colombian participants and six events in five Netherlands participants. This clinical multicentre research complements previous case reports, case series, retrospective and prospective studies on the notion of implant

  3. Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites - thermographic analysis on bovine ribs.

    Science.gov (United States)

    Marković, Aleksa; Lazić, Zoran; Mišić, Tijana; Šćepanović, Miodrag; Todorović, Aleksandar; Thakare, Kaustubh; Janjić, Bojan; Vlahović, Zoran; Glišić, Mirko

    2016-08-01

    During drilling implant sites, mechanical energy is converted into thermal one resulting in transient rise in temperature of surrounding bone. The temperature of 47°C exeeding one minute impairs osseointegration, compromises mechanical properties of the local bone and could cause early implant failure. This in vitro study aimed to assess the effect of surgical drill guide and temperature of irrigans on thermal changes of the local bone during drilling implant sites, and to test the influence of irrigans temperature on the temperature of surgical drill guide. A total of 48 specimens obtained from bovine ribs were randomly allocated to four experimental conditions according to the 2 x 2 factorial design: drill guide (with or without) and saline (at 25°C or 5°C). Real-time infrared thermography was used as a method for temperature measurement. The primary outcome was bone temperature change during drilling implant sites measured at 3 osteotomy depths, whereas the second one was change in the temperature of the drill guide. Data were analyzed by Brunner and Langer nonparametric analysis and Wilcoxon test. The effect of drill guide on the changes of bone temperature was significant at the entrance of osteotomy, whereas the effect of saline temperature was significant at all osteotomy levels (p 0.05). Guided surgery and irrigation with saline at 25°C were associated with the highest bone temperature increase. Increase in drill guide temperature was significantly higher when saline at 25°C was used (p < 0.001). Guided implant site preparation generates higher temperature of the local bone than conventional drilling, not exceeding the threshold for thermal bone necrosis. Although saline at room temperature provides sufficient heat control during drilling, cooled saline is more effective regardless the use of surgical drill guide.

  4. Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites - thermographic analysis on bovine ribs

    Directory of Open Access Journals (Sweden)

    Marković Aleksa

    2016-01-01

    Full Text Available Background/Aim. During drilling implant sites, mechanical energy is converted into thermal one resulting in transient rise in temperature of surrounding bone. The temperature of 47°C exeeding one minute impairs osseointegration, compromises mechanical properties of the local bone and could cause early implant failure. This in vitro study aimed to assess the effect of surgical drill guide and temperature of irrigans on thermal changes of the local bone during drilling implant sites, and to test the influence of irrigans temperature on the temperature of surgical drill guide. Methods. A total of 48 specimens obtained from bovine ribs were randomly allocated to four experimental conditions according to the 2 x 2 factorial design: drill guide (with or without and saline (at 25°C or 5°C. Real-time infrared thermography was used as a method for temperature measurement. The primary outcome was bone temperature change during drilling implant sites measured at 3 osteotomy depths, whereas the second one was change in the temperature of the drill guide. Data were analyzed by Brunner and Langer nonparametric analysis and Wilcoxon test. Results. The effect of drill guide on the changes of bone temperature was significant at the entrance of osteotomy, whereas the effect of saline temperature was significant at all osteotomy levels (p 0.05. Guided surgery and irrigation with saline at 25°C were associated with the highest bone temperature increase. Increase in drill guide temperature was significantly higher when saline at 25°C was used (p < 0.001. Conclusion. Guided implant site preparation generates higher temperature of the local bone than conventional drilling, not exceeding the threshold for thermal bone necrosis. Although saline at room temperature provides sufficient heat control during drilling, cooled saline is more effective regardless the use of surgical drill guide.

  5. Osteogenesis and Morphology of the Peri-Implant Bone Facing Dental Implants

    Directory of Open Access Journals (Sweden)

    Marco Franchi

    2004-01-01

    Full Text Available This study investigated the influence of different implant surfaces on peri-implant osteogenesis and implant face morphology of peri-implant tissues during the early (2 weeks and complete healing period (3 months. Thirty endosseous titanium implants (conic screws with differently treated surfaces (smooth titanium = SS, titanium plasma sprayed = TPS, sand-blasted zirconium oxide = Zr-SLA were implanted in femur and tibiae diaphyses of two mongrel sheep. Histological sections of the implants and surrounding tissues obtained by sawing and grinding techniques were observed under light microscopy (LM. The peri-implant tissues of other samples were mechanically detached from the corresponding implants to be processed for SEM observation. Two weeks after implantation, we observed osteogenesis (new bone trabeculae around all implant surfaces only where a gap was present at the host bone-metal interface. No evident bone deposition was detectable where threads of the screws were in direct contact with the compact host bone. Distance osteogenesis predominated in SS implants, while around rough surfaces (TPS and Zr-SLA, both distance and contact osteogenesis were present. At SEM analysis 2 weeks after implantation, the implant face of SS peri-implant tissue showed few, thin, newly formed, bone trabeculae immersed in large, loose, marrow tissue with blood vessels. Around the TPS screws, the implant face of the peri-implant tissue was rather irregular because of the rougher metal surface. Zr-SLA screws showed more numerous, newly formed bone trabeculae crossing marrow spaces and also needle-like crystals in bone nodules indicating an active mineralising process. After 3 months, all the screws appeared osseointegrated, being almost completely covered by a compact, mature, newly formed bone. However, some marrow spaces rich in blood vessels and undifferentiated cells were in contact with the metal surface. By SEM analysis, the implant face of the peri-implant

  6. Rapid orthodontic treatment after the ridge-splitting technique--a combined surgical-orthodontic approach for implant site development: case report.

    Science.gov (United States)

    Amato, Francesco; Mirabella, A Davide; Borlizzi, Diego

    2012-08-01

    This article presents a clinical case of bilateral partial edentulism in the posterior mandible with severe horizontal and moderate vertical bone atrophy. A new technique using rapid orthodontics after ridge splitting is presented. The split-crest technique was carried out using piezosurgical instruments in the first molar and second premolar areas to widen the bone crest and open a channel for tooth movement. Immediately after, orthodontic appliances were used to move the first premolars distally and the second molars mesially into the surgical site. The rationale was to facilitate and accelerate orthodontic movement of the teeth, which is otherwise difficult in a cortical knife-edged ridge. The bone defect was filled with the alveolar bone of the adjacent teeth that were moved into the surgically opened path. Adequate bone volume for implant placement was generated in the first premolar area. Implants were then inserted, and the patient was rehabilitated.

  7. Surgical Templates for Dental Implant Positioning; Current ...

    African Journals Online (AJOL)

    prosthodontics; however, designing an implant‑supported prosthesis with function .... template where a provisional fixed restoration bridges the implant site. Pesun and ... in single implant therapy or short‑span implant‑supported prostheses.

  8. New-Onset Atrial Fibrillation After Surgical Aortic Valve Replacement and Transcatheter Aortic Valve Implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...... (NOAF) is 31%-64% and 4%-32%, respectively. NOAF is independently associated with adverse events such as stroke, death, and increased length of hospital stay. Increasing the knowledge of predisposing factors, optimal postprocedural monitoring, and prophylactic antiarrhythmic and antithrombotic therapy...

  9. New-onset atrial fibrillation after surgical aortic valve replacement and transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Jørgensen, Troels Højsgaard; Thygesen, Julie Bjerre; Thyregod, Hans Gustav

    2015-01-01

    Surgical aortic valve replacement (SAVR) and, more recently, transcatheter aortic valve implantation (TAVI) have been shown to be the only treatments that can improve the natural cause of severe aortic valve stenosis. However, after SAVR and TAVI, the incidence of new-onset atrial fibrillation...... (NOAF) is 31%-64% and 4%-32%, respectively. NOAF is independently associated with adverse events such as stroke, death, and increased length of hospital stay. Increasing the knowledge of predisposing factors, optimal postprocedural monitoring, and prophylactic antiarrhythmic and antithrombotic therapy...

  10. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  11. Implant Therapy in the Esthetic Zone-Surgical Considerations

    Directory of Open Access Journals (Sweden)

    Marković Aleksa

    2016-07-01

    Full Text Available Implant placement in the esthetic zone is a complex procedure and requires a restoration-driven approach. Proper selection of patients and implant together with individual assessment of the risk of esthetic complications are very important. Correct 3D-implant positioning and sufficient bone volume should provide long-term esthetic and function. Esthetic region is a zone in which expectations and possibilities collide. Clinician should bring the important decision on the appropriate time of implant placement. Immediate implant placement is particularly challenging in the esthetic zone. Patient desire for reduced treatment time should be weighed against the possible risk factors. Protocol of immediate implant placement in conditions of unfavourable gingival biotypes, the lack of bone or soft tissue in patients with a high smile line lead to esthetic failure which is very important in the esthetic region.

  12. Ion implantation technology

    CERN Document Server

    Downey, DF; Jones, KS; Ryding, G

    1993-01-01

    Ion implantation technology has made a major contribution to the dramatic advances in integrated circuit technology since the early 1970's. The ever-present need for accurate models in ion implanted species will become absolutely vital in the future due to shrinking feature sizes. Successful wide application of ion implantation, as well as exploitation of newly identified opportunities, will require the development of comprehensive implant models. The 141 papers (including 24 invited papers) in this volume address the most recent developments in this field. New structures and possible approach

  13. Effects of noble-metal ion implantation on corrosion inhibition and charge injection capability of surgical Ti and Ti-6Al-4V

    International Nuclear Information System (INIS)

    Lee, I.S.

    1989-01-01

    Studies are described involving effects of noble-metal ion implantation on corrosion inhibition and charge injection capabilities of surgical Ti and Ti-6Al-4V. With surgical alloys, harmful biological responses are principally due to the type and quantity of metal ions released by the corrosion process. One approach to improve long-term biological performance involves surface modifications to significantly reduce degradation rates. With regard to surface-modifications, one of the most effective methods is through ion implantation. Results are presented for ion-implanted Au, Rh, and Ir. For the static in vitro corrosion properties, the noble-metal ion implanted Ti-6Al-4V and commercially-pure (CP) Ti were investigated in non-passivating acid and passivating saline solutions. It was postulated that during the early stages of corrosion (or during a corrosion pretreatment) the implanted noble-metal would enrich at the surface and significantly reduce subsequent corrosion rates. The observed behavior for the Ir and Rh implanted materials appeared to follow the postulated mechanism, with both initial and time-dependent improvements in corrosion resistance. However, the Au implanted material yielded early benefits, but the enhanced corrosion resistance deteriorated with time. X-ray photoelectron spectroscopy (XPS) analysis indicated that the implanted Au atoms remained as pure metallic Au, while the Ir and Rh atoms were in some oxide state, which gave the good adhesion of the Ir or Rh enriched surface to the Ti substrate. For a stimulating neural electrode, the charge density should be as large as possible to provide adequate stimulation of the nervous system while allowing for miniaturization of the electrode. Activated Ir has been known as having the highest charge injection capability of any material known

  14. Reliability of Soft Tissue Model Based Implant Surgical Guides; A Methodological Mistake.

    Science.gov (United States)

    Sabour, Siamak; Dastjerdi, Elahe Vahid

    2012-08-20

    Abstract We were interested to read the paper by Maney P and colleagues published in the July 2012 issue of J Oral Implantol. The authors aimed to assess the reliability of soft tissue model based implant surgical guides reported that the accuracy was evaluated using software. 1 I found the manuscript title of Maney P, et al. incorrect and misleading. Moreover, they reported twenty-two sites (46.81%) were considered accurate (13 of 24 maxillary and 9 of 23 mandibular sites). As the authors point out in their conclusion, Soft tissue models do not always provide sufficient accuracy for implant surgical guide fabrication.Reliability (precision) and validity (accuracy) are two different methodological issues in researches. Sensitivity, specificity, PPV, NPV, likelihood ratio positive (true positive/false negative) and likelihood ratio negative (false positive/ true negative) as well as odds ratio (true results\\false results - preferably more than 50) are among the tests to evaluate the validity (accuracy) of a single test compared to a gold standard.2-4 It is not clear that the reported twenty-two sites (46.81%) which were considered accurate related to which of the above mentioned estimates for validity analysis. Reliability (repeatability or reproducibility) is being assessed by different statistical tests such as Pearson r, least square and paired t.test which all of them are among common mistakes in reliability analysis 5. Briefly, for quantitative variable Intra Class Correlation Coefficient (ICC) and for qualitative variables weighted kappa should be used with caution because kappa has its own limitation too. Regarding reliability or agreement, it is good to know that for computing kappa value, just concordant cells are being considered, whereas discordant cells should also be taking into account in order to reach a correct estimation of agreement (Weighted kappa).2-4 As a take home message, for reliability and validity analysis, appropriate tests should be

  15. Influence of surgical and prosthetic techniques on marginal bone loss around titanium implants. Part I: immediate loading in fresh extraction sockets.

    Science.gov (United States)

    Berberi, Antoine N; Tehini, Georges E; Noujeim, Ziad F; Khairallah, Alexandre A; Abousehlib, Moustafa N; Salameh, Ziad A

    2014-10-01

    Delayed placement of implant abutments has been associated with peri-implant marginal bone loss; however, long-term results obtained by modifying surgical and prosthetic techniques after implant placement are still lacking. This study aimed to evaluate the marginal bone loss around titanium implants placed in fresh extraction sockets using two loading protocols after a 5-year follow-up period. A total of 36 patients received 40 titanium implants (Astra Tech) intended for single-tooth replacement. Implants were immediately placed into fresh extraction sockets using either a one-stage (immediate loading by placing an interim prosthesis into functional occlusion) or a two-stage prosthetic loading protocol (insertion of abutments after 8 weeks of healing time). Marginal bone levels relative to the implant reference point were evaluated at four time intervals using intraoral radiographs: at time of implant placement, and 1, 3, and 5 years after implant placement. Measurements were obtained from mesial and distal surfaces of each implant (α = 0.05). One-stage immediate implant placement into fresh extraction sockets resulted in a significant reduction in marginal bone loss (p sockets reduced marginal bone loss and did not compromise the success rate of the restorations. © 2014 by the American College of Prosthodontists.

  16. Surgical implantation of intra-abdominal radiotransmitters in marine otters (Lontra felina) in central Chile.

    Science.gov (United States)

    Soto-Azat, Claudio; Boher, Francisca; Fabry, Mauricio; Pascual, Paulo; Medina-Vogel, Gonzalo

    2008-10-01

    Six free-ranging marine otters (Lontra felina) were livetrapped on the central coast of Chile and implanted with specially designed radiotransmitters as part of a spatial ecology study. Marine otters frequent the rocky seashore, often squeezing their narrow bodies through cracks and crevices and grooming themselves on the rocks. They are also among the smallest of the otter species, weighing between 3.4 kg and 4.5 kg. For these reasons, the transmitter used was small, rectangular, and flat, measuring 3.5 x 3.2 x 1.0 cm. They were implanted using a ventral midline approach to minimize contact between the skin incision and sharp-edged rocks. Surgical incisions healed within 2 wk. The transmitters functioned well, but the duration varied from 62 days to 143 days instead of the 240 days predicted by the manufacturer. All six marine otters reestablished in their home ranges, and survey results suggest they survived well beyond the life of the transmitters.

  17. Prognostic indicators for surgical peri-implantitis treatment

    NARCIS (Netherlands)

    de Waal, Yvonne C M; Raghoebar, Gerry M; Meijer, Henny J A; Winkel, Edwin G; van Winkelhoff, Arie Jan

    2016-01-01

    Objectives: Objective of this study was to identify prognostic indicators for the outcome of resective peri-implantitis treatment, by an analysis of the pooled data of two previously conducted randomized controlled trials. Material and methods: Data of 74 patients with peri-implantitis (187

  18. Peri-implant osseointegration after low-level laser therapy: micro-computed tomography and resonance frequency analysis in an animal model.

    Science.gov (United States)

    Mayer, Luciano; Gomes, Fernando Vacilotto; de Oliveira, Marília Gerhardt; de Moraes, João Feliz Duarte; Carlsson, Lennart

    2016-12-01

    The purpose of the present study is to evaluate the effects of low-level laser therapy on the osseointegration process by comparing resonance frequency analysis measurements performed at implant placement and after 30 days and micro-computed tomography images in irradiated vs nonirradiated rabbits. Fourteen male New Zealand rabbits were randomly divided into two groups of seven animals each, one control group (nonirradiated animals) and one experimental group that received low-level laser therapy (Thera Lase®, aluminum-gallium-arsenide laser diode, 10 J per spot, two spots per session, seven sessions, 830 nm, 50 mW, CW, Ø 0.0028 cm 2 ). The mandibular left incisor was surgically extracted in all animals, and one osseointegrated implant was placed immediately afterward (3.25ø × 11.5 mm; NanoTite, BIOMET 3i). Resonance frequency analysis was performed with the Osstell® device at implant placement and at 30 days (immediately before euthanasia). Micro-computed tomography analyses were then conducted using a high-resolution scanner (SkyScan 1172 X-ray Micro-CT) to evaluate the amount of newly formed bone around the implants. Irradiated animals showed significantly higher implant stability quotients at 30 days (64.286 ± 1.596; 95 % confidence interval (CI) 60.808-67.764) than controls (56.357 ± 1.596; 95 %CI 52.879-59.835) (P = .000). The percentage of newly formed bone around the implants was also significantly higher in irradiated animals (75.523 ± 8.510; 95 %CI 61.893-89.155) than in controls (55.012 ± 19.840; 95 %CI 41.380-68.643) (P = .027). Laser therapy, based on the irradiation protocol used in this study, was able to provide greater implant stability and increase the volume of peri-implant newly formed bone, indicating that laser irradiation effected an improvement in the osseointegration process.

  19. Surgical outcomes of trabeculectomy and glaucoma drainage implant for uveitic glaucoma and relationship with uveitis activity.

    Science.gov (United States)

    Kwon, Hye Jin; Kong, Yu Xiang George; Tao, Lingwei William; Lim, Lyndell L; Martin, Keith R; Green, Catherine; Ruddle, Jonathan; Crowston, Jonathan G

    2017-07-01

    This study provides ophthalmologists who manage uveitic glaucoma with important information on factors that can affect the success of surgical management of this challenging disease. This study examines surgical outcomes of trabeculectomy and glaucoma device implant (GDI) surgery for uveitic glaucoma, in particular the effect of uveitis activity on surgical outcomes. Retrospective chart review at a tertiary institution. Eighty-two cases with uveitic glaucoma (54 trabeculectomies and 28 (GDI) surgeries) performed between 1 December 2006 and 30 November 2014. Associations of factors with surgical outcomes were examined using univariate and multivariate analysis. Surgical outcomes as defined in Guidelines from World Glaucoma Association. Average follow up was 26.4 ± 21.5 months. Overall qualified success rate of the trabeculectomies was not statistically different from GDI, being 67% and 75%, respectively (P = 0.60). Primary and secondary GDI operations showed similar success rates. The most common postoperative complication was hypotony (~30%). Active uveitis at the time of operation was higher in trabeculectomy compared with GDI group (35% vs. 14%). Active uveitis at the time of surgery did not significantly increase risk of failure for trabeculectomies. Recurrence of uveitis was significantly associated with surgical failure in trabeculectomy group (odds ratio 4.8, P = 0.02) but not in GDI group. Surgical success rate of GDI was not significantly different from trabeculectomy for uveitic glaucoma in this study. Regular monitoring, early and prolonged intensive treatment of ocular inflammation is important for surgical success particularly following trabeculectomy. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  20. Customizable cap implants for neurophysiological experimentation.

    Science.gov (United States)

    Blonde, Jackson D; Roussy, Megan; Luna, Rogelio; Mahmoudian, Borna; Gulli, Roberto A; Barker, Kevin C; Lau, Jonathan C; Martinez-Trujillo, Julio C

    2018-04-22

    Several primate neurophysiology laboratories have adopted acrylic-free, custom-fit cranial implants. These implants are often comprised of titanium or plastic polymers, such as polyether ether ketone (PEEK). Titanium is favored for its mechanical strength and osseointegrative properties whereas PEEK is notable for its lightweight, machinability, and MRI compatibility. Recent titanium/PEEK implants have proven to be effective in minimizing infection and implant failure, thereby prolonging experiments and optimizing the scientific contribution of a single primate. We created novel, customizable PEEK 'cap' implants that contour to the primate's skull. The implants were created using MRI and/or CT data, SolidWorks software and CNC-machining. Three rhesus macaques were implanted with a PEEK cap implant. Head fixation and chronic recordings were successfully performed. Improvements in design and surgical technique solved issues of granulation tissue formation and headpost screw breakage. Primate cranial implants have traditionally been fastened to the skull using acrylic and anchor screws. This technique is prone to skin recession, infection, and implant failure. More recent methods have used imaging data to create custom-fit titanium/PEEK implants with radially extending feet or vertical columns. Compared to our design, these implants are more surgically invasive over time, have less force distribution, and/or do not optimize the utilizable surface area of the skull. Our PEEK cap implants served as an effective and affordable means to perform electrophysiological experimentation while reducing surgical invasiveness, providing increased strength, and optimizing useful surface area. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  1. In Vivo Tooth-Supported Implant Surgical Guides Fabricated With Desktop Stereolithographic Printers: Fully Guided Surgery Is More Accurate Than Partially Guided Surgery.

    Science.gov (United States)

    Bencharit, Sompop; Staffen, Adam; Yeung, Matthew; Whitley, Daniel; Laskin, Daniel M; Deeb, George R

    2018-02-21

    Desktop stereolithographic printers combined with intraoral scanning and implant planning software promise precise and cost-effective guided implant surgery. The purpose of the present study was to determine the overall range of accuracy of tooth-supported guided implant surgery using desktop printed stereolithographic guides. A cross-sectional study comparing fully and partially guided implant surgery was conducted. Preoperative cone beam computed tomography (CBCT) and intraoral scans were used to plan the implant sites. Surgical guides were then fabricated using a desktop stereolithographic 3-dimensional printer. Postoperative CBCT was used to evaluate the accuracy of placement. Deviations from the planned positions were used as the primary outcome variables. The planning software used, implant systems, and anterior/posterior positions were the secondary outcome variables. The differences between the planned and actual implant positions in the mesial, distal, buccal, and lingual dimensions and buccolingual angulations were determined, and the accuracy was compared statistically using the 1-tail F-test (P = .01), box plots, and 95% confidence intervals for the mean. Sixteen partially edentulous patients requiring placement of 31 implants were included in the present study. The implant deviations from the planned positions for mesial, distal, buccal, and lingual dimensions and buccolingual angulations with the fully guided protocol (n = 20) were 0.17 ± 0.78 mm, 0.44 ± 0.78 mm, 0.23 ± 1.08 mm, -0.22 ± 1.44 mm, and -0.32° ± 2.36°, respectively. The corresponding implant deviations for the partially guided protocol (n = 11) were 0.33 ± 1.38 mm, -0.03 ± 1.59 mm, 0.62 ± 1.15 mm, -0.27 ± 1.61 mm, and 0.59° ± 6.83°. The difference between the variances for fully and partially guided surgery for the distal and angulation dimensions was statistically significant (P = .006 and P guided implant surgery is more accurate than

  2. The zygomatic implant perforated (ZIP) flap: a new technique for combined surgical reconstruction and rapid fixed dental rehabilitation following low-level maxillectomy.

    Science.gov (United States)

    Butterworth, C J; Rogers, S N

    2017-12-01

    This aim of this report is to describe the development and evolution of a new surgical technique for the immediate surgical reconstruction and rapid post-operative prosthodontic rehabilitation with a fixed dental prosthesis following low-level maxillectomy for malignant disease.The technique involves the use of a zygomatic oncology implant perforated micro-vascular soft tissue flap (ZIP flap) for the primary management of maxillary malignancy with surgical closure of the resultant maxillary defect and the installation of osseointegrated support for a zygomatic implant-supported maxillary fixed dental prosthesis.The use of this technique facilitates extremely rapid oral and dental rehabilitation within a few weeks of resective surgery, providing rapid return to function and restoring appearance following low-level maxillary resection, even in cases where radiotherapy is required as an adjuvant treatment post-operatively. The ZIP flap technique has been adopted as a standard procedure in the unit for the management of low-level maxillary malignancy, and this report provides a detailed step-by-step approach to treatment and discusses modifications developed over the treatment of an initial cohort of patients.

  3. Original Solution for Middle Ear Implant and Anesthetic/Surgical Management in a Child with Severe Craniofacial Dysmorphism

    Directory of Open Access Journals (Sweden)

    Giovanni Bianchin

    2015-01-01

    Full Text Available We describe the novel solution adopted in positioning middle ear implant in a child with bilateral congenital aural atresia and craniofacial dysmorphism that have posed a significant challenge for the safe and correct management of deafness. A five-year-old child, affected by a rare congenital disease (Van Maldergem Syndrome, suffered from conductive hearing loss. Conventional skin-drive bone-conduction device, attached with a steel spring headband, has been applied but auditory restoration was not optimal. The decision made was to position Vibrant Soundbridge, a middle ear implant, with an original surgical application due to hypoplasia of the tympanic cavity. Intubation procedure was complicated due to child craniofacial deformities. Postoperative hearing rehabilitation involved a multidisciplinary team, showing improved social skills and language development.

  4. A New Detection Method for Submerged Implants: Oral Tattoo.

    Science.gov (United States)

    Soylu, Emrah; Gönen, Zeynep Burçin; Alkan, Alper

    2018-04-01

    To evaluate the marking potential of tattoo ink in determining the definitive locations of submerged implants at the time of surgical exposure of the implants. In total, 104 implants in 32 patients were included in this study. After placement of the implants, cover screws were inserted. Overlying mucosa was marked with tattoo ink using a 20 g needle through the center of the cover screw. At the time of surgical exposure the tattoo marks were evaluated relative to visibility. At the time of the surgical exposures, tattoo ink was clearly visible at 91 implants, slightly visible at 8 implants, and not visible at 5 implants. After detection and classification of tattoo ink, the overlying mucosa was gently removed by tissue punch under local anesthesia. The results of this study seemed to indicate that marking the location of implants with tattoos at the time of implant placement can be an inexpensive, easy, healthy, and practical way to identify the location of marked submerged dental implants. © 2016 by the American College of Prosthodontists.

  5. Comparison of five-axis milling and rapid prototyping for implant surgical templates.

    Science.gov (United States)

    Park, Ji-Man; Yi, Tae-Kyoung; Koak, Jai-Young; Kim, Seong-Kyoon; Park, Eun-Jin; Heo, Seong-Joo

    2014-01-01

    This study aims to compare and evaluate the accuracy of surgical templates fabricated using coordinate synchronization processing with five-axis milling and design-related processing with rapid prototyping (RP). Master phantoms with 10 embedded gutta-percha cylinders hidden under artificial gingiva were fabricated and imaged using cone beam computed tomography. Vectors of the hidden cylinders were extracted and transferred to those of the planned implants through reverse engineering using virtual planning software. An RP-produced template was fabricated by stereolithography in photopolymer at the RP center according to planned data. Metal sleeves were bonded after holes were bored (group RP). For the milled template, milling coordinates were synchronized using the conversion process for the coordinate synchronization platform located on the model's bottom. Metal bushings were set on holes milled on the five-axis milling machine, on which the model was fixed through the coordinate synchronization plate, and the framework was constructed on the model using orthodontic resin (group CS). A computed tomography image was taken with templates firmly fixed on models using anchor pins (RP) or anchor screws (CS). The accuracy was analyzed via reverse engineering. Differences between the two groups were compared by repeated measures two-factor analysis. From the reverse-engineered image of the template on the experimental model, RP-produced templates showed significantly larger deviations than did milled surgical guides. Maximum deviations of the group RP were 1.58 mm (horizontal), 1.68 mm (vertical), and 8.51 degrees (angular); those of the group CS were 0.68 mm (horizontal), 0.41 mm (vertical), and 3.23 degrees (angular). A comparison of milling and RP template production methods showed that a vector-milled surgical guide had significantly smaller deviations than did an RP-produced template. The accuracy of computer-guided milled surgical templates was within the safety

  6. Image-guided navigation system for placing dental implants.

    Science.gov (United States)

    Casap, Nardy; Wexler, Alon; Lustmann, Joshua

    2004-10-01

    Navigation-guided surgery has recently been introduced into various surgical disciplines, including oral and maxillofacial surgery. Since the advent of dental implants, dental computed tomography (CT) scans have been used as a diagnostic tool for preoperative planning, but not as part of the surgical phase. This article explains the principles of computer-assisted surgery and describes the use of a computer-guided navigation system in dental implantology. The system uses preoperative dental CT scans for planning and as an integral part of the surgical procedure. This system allows continuous intraoperative coordination of the implantation phase with the preoperative plan, optimizing the accuracy of implant surgery. Deviations from the planned location of the implants are minimal. Several cases are discussed.

  7. Diagnostic Imaging for Dental Implant Therapy

    Directory of Open Access Journals (Sweden)

    Aishwarya Nagarajan

    2014-01-01

    Full Text Available Dental implant is a device made of alloplastic (foreign material implanted into the jaw bone beneath the mucosal layer to support a fixed or removable dental prosthesis. Dental implants are gaining immense popularity and wide acceptance because they not only replace lost teeth but also provide permanent restorations that do not interfere with oral function or speech or compromise the self-esteem of a patient. Appropriate treatment planning for replacement of lost teeth is required and imaging plays a pivotal role to ensure a satisfactory outcome. The development of pre-surgical imaging techniques and surgical templates helps the dentist place the implants with relative ease. This article focuses on various types of imaging modalities that have a pivotal role in implant therapy.

  8. Fourteen-years experience with cochlear implantation in Ramathibodi Hospital.

    Science.gov (United States)

    Kasemsuwan, Lalida; Cheewaruangroj, Wichit; Tungkeeratichai, Jumroon; Bhongmakapat, Thongchai; Thawin, Cheamchit; Lertsukprasert, Krisna; Tiravanitchakul, Rattinan; Dara, Rada; Laothamatas, Jiraporn

    2010-12-01

    To review the cochlear implant program in Ramathibodi Hospital and share experience of cochlear implantation emphasized on clinical and surgical outcomes. Retrospective review of 143 ears (140 patients) operated with cochlear implant between 1995 and 2009. The demographic data including etiology of deafness and findings from temporal bone CTscans were reviewed. The authors' experience with cochlear implant surgery in terms of patient selection, patient advisory clinic, necessary equipment, pre- and postoperative evaluations, surgical techniques and complications were discussed. Most congenital origin was unknown etiology and congenital rubella was the most common known cause. From the CT scans of congenital deafness, vestibular aqueduct dilatation was the most common and found in 29.31% while Mondini malformation was shown to be 16.37%. The authors' surgical technique of using the pocket method and designed bony ridge at cortical mastoid rim had helped stabilizing the implant and electrode fancoil. During the last two years, no complication or revision surgery was detected. Cochlear implant surgery in both children and adults can result in good surgical outcome and fewer complications under experienced surgeons and a good team.

  9. Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory study.

    NARCIS (Netherlands)

    Tabassum, A.; Meijer, G.J.; Wolke, J.G.C.; Jansen, J.A.

    2009-01-01

    OBJECTIVE: The aim of this biomechanical study was to assess the effect of surgical technique and surface roughness on primary implant stability in low-density bone. MATERIAL AND METHODS: Eighty screw-shaped (Biocomp) implants with machined or etched surface topography were inserted into a

  10. Implant-Supported PMMA Monolithic Full-Arch Rehabilitation with Surgical Computer-Planned Guide and Immediate Provisional: A Case Report with One Year Follow-Up

    Directory of Open Access Journals (Sweden)

    Vincenzo Luca Zizzari

    2018-01-01

    Full Text Available The aim of this case report is to describe the surgical and prosthetic procedures to achieve maxillary and mandibular implant-supported PMMA monolithic full-arch rehabilitation (PMFR with surgical computer-planned guide and immediate provisional. In such cases, the correct planning of dental implants’ position, length, and diameter and the prosthetic phases via computer-aided design are very important to achieve good aesthetic and functional long-lasting results.

  11. Implant-Supported PMMA Monolithic Full-Arch Rehabilitation with Surgical Computer-Planned Guide and Immediate Provisional: A Case Report with One Year Follow-Up

    OpenAIRE

    Zizzari, Vincenzo Luca; Tacconelli, Gianmarco

    2018-01-01

    The aim of this case report is to describe the surgical and prosthetic procedures to achieve maxillary and mandibular implant-supported PMMA monolithic full-arch rehabilitation (PMFR) with surgical computer-planned guide and immediate provisional. In such cases, the correct planning of dental implants’ position, length, and diameter and the prosthetic phases via computer-aided design are very important to achieve good aesthetic and functional long-lasting results.

  12. Hard and soft tissue surgical complications in dental implantology.

    Science.gov (United States)

    Aziz, Shahid R

    2015-05-01

    This article discusses surgical complications associated with the placement of dental implants, specifically focusing on how they occur (etiology), as well as their management and prevention. Dental implant surgical complications can be classified into those of hard and soft tissues. In general, complications can be avoided with thorough preoperative treatment planning and proper surgical technique. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. [Intraocular lens implantation with one loop haptic amputated: a new propose to the subluxation lens surgical treatment].

    Science.gov (United States)

    Ventura, Marcelo; Endriss, Daniela

    2010-01-01

    To evaluate the postoperative results of congenital lens subluxation corrected by a new technique. Retrospective chart review of 21 eyes of 13 patients with no traumatic lens subluxation who underwent surgery in Altino Ventura Foundation from April, 1999 to April, 2004. The mean age was 8.7 +/- 5.4 years old, and the mean follow-up period was 21.5 +/- 19.3 months. Patients underwent phacoaspiration, endocapsular ring and intraocular lens (IOL) implantation. The implanted IOL had one loop haptic excised and was supported above the ring, inside the capsular bag promoting intraocular lens centralization. Visual acuity improvement was observed in all cases. There was a significant reduction of the spherical equivalent and spherical component comparing the pre and postoperative refraction (psubluxation surgical treatment, promoting lens centralization and postoperative visual acuity improvement.

  14. Long time follow up of implant therapy and treatment of peri-implantitis.

    Science.gov (United States)

    Roos-Jansåker, Ann-Marie

    2007-01-01

    Dental implants have become an often used alternative to replace missing teeth, resulting in an increasing percentage of the adult population with implant supported prosthesis. Although favourable long-term results of implant therapy have been reported, infections occur. Until recently few reports included data on peri-implant infections, possibly underestimating this complication of implant treatment. It is possible that some infections around implants develop slowly and that with time peri-implantitis will be a common complication to implant therapy as an increasing number of patients have had their implants for a long time (>10 years). Data on treatment of peri-implant lesions are scarce leaving the clinician with limited guidance regarding choice of treatment. The aim of this thesis was to study the frequency of implant loss and presence of peri-implant lesions in a group of patients supplied with Brånemark implants 9-14 years ago, and to relate these events to patient and site specific characteristics. Moreover three surgical treatment modalities for peri-implantitis were evaluated. The thesis is based on six studies; Studies I-III included 218 patients and 1057 implants followed for 9-14 years evaluating prevalence of, and factors related to implant loss (Paper I) and prevalence of peri-implant infections and related factors (Paper I-III). Study IV is a review describing different treatment modalities of peri-implant infections. Study V is a prospective cohort study involving 36 patients and 65 implants, evaluating the use of a bone substitute with or without the use of a resorbable membrane. Study VI is a case series with 12 patients and 16 implants, evaluating a bone substitute in combination with a resorbable membrane and submerged healing. This thesis demonstrated that: After 9-14 years the survival rates of dental implants are high (95.7%). Implant loss seems to cluster within patients and are related to periodontitis evidenced as bone loss on

  15. Small Intestinal Submucosa Implantation for the Possible Treatment of Vocal Fold Scar, Sulcus, and Superficial Lamina Propria Atrophy.

    Science.gov (United States)

    Pitman, Michael J; Cabin, Jonathan A; Iacob, Codrin E

    2016-02-01

    Evaluate the histologic effects of grafting porcine-derived small intestinal submucosa (SIS) into the vocal fold superficial lamina propria (SLP) layer for the potential treatment of vocal fold scar, sulcus and superficial lamina propria atrophy. Small intestinal submucosa was implanted into the right vocal fold SLP of 6 mongrel dogs. The left vocal fold served as a sham surgical control. At 2, 4, and 6 weeks postoperative, bilateral vocal fold specimens were evaluated histologically. At 2 and 4 weeks, respectively, SIS-implanted vocal folds demonstrated moderate and mild inflammation and acute and chronic inflammation. At 6 weeks, inflammation was minimal and chronic. The 6-week specimens showed copious amounts of newly generated hyaluronic acid (HA) within the graft. There was no reactive fibrosis at 6 weeks. In the canine model, SIS appears safe for SLP grafting. Inflammation is similar to that of sham surgery. Small intestinal submucosa results in newly generated HA without concomitant fibrosis. Small intestinal submucosa has potential to be used in treatment of disorders with SLP, including vocal fold scar, sulcus, and atrophy. Studies evaluating the effect of SIS implantation on vocal fold function, as well as the ultimate fate of the graft, are required. © The Author(s) 2015.

  16. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

    Directory of Open Access Journals (Sweden)

    M Isabel Canut Jordana

    2010-11-01

    Full Text Available M Isabel Canut Jordana1, Daniel Pérez Formigó1, Rodrigo Abreu González2, Jeroni Nadal Reus11Barraquer Ophthalmology Centre, Barcelona, Spain; 2University Hospital of La Candelaria, Tenerife, SpainAims: We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact.Methods: Complete ophthalmologic examination and optical coherence tomography (OCT of the anterior segment were performed.Results: Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control.Conclusion: Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.Keywords: pigmentary glaucoma, intraocular lens, optical coherence tomography, laser

  17. The effect of different surgical drilling procedures on full laser-etched microgrooves surface-treated implants: an experimental study in sheep.

    Science.gov (United States)

    Jimbo, Ryo; Tovar, Nick; Yoo, Daniel Y; Janal, Malvin N; Anchieta, Rodolfo B; Coelho, Paulo G

    2014-09-01

    To evaluate the influence of instrumentation technique on the early osseointegration histomorphometrics and biomechanical fixation of fully laser-etched microgrooves implant surfaces in a sheep model. Six sheep were subjected to bilateral hip surgeries 3 and 6 weeks before euthanasia. A total of 48 implants (∅4.5 mm, 8 mm in length) were distributed among four sites (8 per animal) and placed in bone sites drilled to 4.6 mm (reamer), 4.1 mm (loose), 3.7 mm (medium) and 3.2 mm (tight) in diameter. After healing, the animals were euthanized and half of the implants were biomechanically tested, while the remainder was subjected to non-decalcified histologic processing. The histomorphometric parameters assessed were bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). Statistical analysis was performed using a mixed-model analysis of variance with significance level set at P bone seemed to be in contact to the implant surface, at 3 weeks, whereas the implants placed in press-fit situations were mainly supported by cortical bone. The laser-etched microgrooved implant presented osteoconductive and biocompatible properties for all surgical procedures tested. However, procedures providing increasingly higher press-fit scenarios presented the strongest histomorphometric and biomechanical responses at 3 and 6 weeks. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Repair of spinal cord injury by implantation of bFGF-incorporated HEMA-MOETACL hydrogel in rats

    Science.gov (United States)

    Chen, Bo; He, Jianyu; Yang, Hao; Zhang, Qian; Zhang, Lingling; Zhang, Xian; Xie, En; Liu, Cuicui; Zhang, Rui; Wang, Yi; Huang, Linhong; Hao, Dingjun

    2015-03-01

    There is no effective strategy for the treatment of spinal cord injury (SCI). An appropriate combination of hydrogel materials and neurotrophic factor therapy is currently thought to be a promising approach. In this study, we performed experiments to evaluate the synergic effect of implanting hydroxyl ethyl methacrylate [2-(methacryloyloxy)ethyl] trimethylammonium chloride (HEMA-MOETACL) hydrogel incorporated with basic fibroblast growth factor (bFGF) into the site of surgically induced SCI. Prior to implantation, the combined hydrogel was surrounded by an acellular vascular matrix. Sprague-Dawley rats underwent complete spinal cord transection at the T-9 level, followed by implantation of bFGF/HEMA-MOETACL 5 days after transection surgery. Our results showed that the bFGF/HEMA-MOETACL transplant provided a scaffold for the ingrowth of regenerating tissue eight weeks after implantation. Furthermore, this newly designed implant promoted both nerve tissue regeneration and functional recovery following SCI. These results indicate that HEMA-MOETACL hydrogel is a promising scaffold for intrathecal, localized and sustained delivery of bFGF to the injured spinal cord and provide evidence for the possibility that this approach may have clinical applications in the treatment of SCI.

  19. [Clinical experience in osteoplastic material Allomatrix-implant and fibrin rich platelets use in surgical treatment of jaw radicular cysts].

    Science.gov (United States)

    Kuz'minykh, I A

    2009-01-01

    Bones forming optimizators applying in surgical dentistry is an important element of jaw destructive processes successful treatment. Today use of osteoplastic materials on the collagen basis is widely spread. One of this challenge solution is FRP and Allomatrix-implant material applying to jaws during surgery operations. We described clinical investigation phase: the estimation of postoperative and remote results of treatment was carried out.

  20. Surgical timing for bilateral simultaneous cochlear implants: When is best?

    Science.gov (United States)

    Franchella, Sebastiano; Bovo, Roberto; Bandolin, Luigia; Gheller, Flavia; Montino, Silvia; Borsetto, Daniele; Ghiselli, Sara; Martini, Alessandro

    2018-06-01

    Hearing loss is considered the most common congenital disease and the prevalence of neonatal deafness can be estimated between 1 and 2 cases per 1000 live births. Infant deafness must be diagnosed as early as possible and an effective therapeutic intervention needs to be carried out in order to avoid the serious consequences of hearing deprivation during the evolutionary period: alterations in the development of central auditory pathways and lack of language acquisition. The cochlear implant (CI) has proved to be the best instrument to solve the problem of auditory deprivation. In particular, the bilateral CI gives the patient access to binaural hearing which results in benefits in terms of sound localisation and discrimination. The optimal age of application of the CI is a widely discussed topic in the scientific community and the current guidelines indicate a period between 12 and 24 months of age, even though the supporters of the application before 12 months of age are nowadays increasing. The study is observational, retrospective, monocentric. 49 paediatric patients (<18 years) with simultaneous bilateral CIs were included. The audiometric threshold and speech tests were carried out during the follow-up 3, 6 and 12 months after the CIs activation and when the patient reached 2 years of age. The statistical analysis showed that undergoing bilateral implantation surgery before 2 years of age allows a satisfactory audiometric performance, while there are no particular benefits in performing the surgery before 1 year of age. As far as the speech outcome is concerned, the statistical analysis didn't show significant correlation between the earlier age of implantation and better speech performance if the operation is carried out before 2.5 years of age. The results of the study indicate that the optimal age to perform the simultaneous bilateral CIs surgery is between 12 and 24 months, without demonstrating any particular benefit in carrying out the procedure before

  1. Evolving practices in augmentation operative technique with Sientra HSC round implants.

    Science.gov (United States)

    Calobrace, M Bradley; Kaufman, David L; Gordon, Ashley E; Reid, Dustin L

    2014-07-01

    As of 2012, breast augmentation surgery continues to be the most commonly performed aesthetic surgical procedure in the United States. Surgeons consider a multitude of factors when choosing the type and style of breast implant for a patient. With the continuous evolution of breast implant designs, there are a variety of breast implant options for plastic surgeons to choose from; however, round implants remain the implant of choice for breast augmentation. This article discusses preoperative planning, implant selection, surgical techniques, and postoperative management using Sientra's Silimed brand smooth and textured round implants.

  2. The flaws in the detail of an observational study on transcatheter aortic valve implantation versus surgical aortic valve replacement in intermediate-risks patients

    NARCIS (Netherlands)

    Barili, Fabio; Freemantle, Nick; Folliguet, Thierry; Muneretto, Claudio; de Bonis, Michele; Czerny, Martin; Obadia, Jean Francois; Al-Attar, Nawwar; Bonaros, Nikolaos; Kluin, Jolanda; Lorusso, Roberto; Punjabi, Prakash; Sadaba, Rafael; Suwalski, Piotr; Benedetto, Umberto; Böning, Andreas; Falk, Volkmar; Sousa-Uva, Miguel; Kappetein, Pieter A.; Menicanti, Lorenzo

    2017-01-01

    The PARTNER group recently published a comparison between the latest generation SAPIEN 3 transcatheter aortic valve implantation (TAVI) system (Edwards Lifesciences, Irvine, CA, USA) and surgical aortic valve replacement (SAVR) in intermediate-risk patients, apparently demonstrating superiority of

  3. Assessment of conditions affecting surgical success of Ahmed glaucoma valve implants in glaucoma secondary to different uveitis etiologies in adults.

    Science.gov (United States)

    Sungur, G; Yakin, M; Eksioglu, U; Satana, B; Ornek, F

    2017-10-01

    PurposeThere is little known about the long-term efficacy and safety of Ahmed glaucoma valve (AGV) implant and about the conditions affecting surgical success in uveitic glaucoma (UG).Patients and methodsThe charts of adult patients with UG who underwent AGV implantation from 2006 to 2015 were reviewed retrospectively.ResultsData of 46 eyes of 39 patients were evaluated. Mean follow-up was 51.93±23.08 months. Mean preoperative IOP was 37.05±9.62 mm Hg and mean number of preoperative topical anti-glaucomatous medications was 2.98±0.27. One eye (2%) was defined as failure because of implant extraction surgery. In the rest of the eyes, intraocular pressure (IOP) was under control with or without anti-glaucomatous medications during follow-up. The cumulative probability of complete success (IOP control without medications) was 78% at 6 months, 76% at 1 year, 71% at 2 years, 66% at 3 years, and 63% at 4 years (95% confidence interval, 61.24-87.81). The cumulative probability of eyes without complication was 64% at 6 months, 48% at 12 months, 44% at 24 months, 41% at 36 months, and 38% at 48 months (95% confidence interval, 34.64-62.85). Complete success was lower in eyes with previous ocular surgery than the eyes without (P=0.061) and it was lower in eyes with active inflammation at the time of surgery than the eyes without (P=0.011).ConclusionAGV implantation is an effective and safe alternative method in the management of UG, especially when it is performed as a primary surgical option and when no inflammation is present preoperatively.

  4. CLINICAL CONSIDERATIONS OF DENTAL IMPLANT SYSTEM IN IMMEDIATE LOADING IMPLANT CASES

    Directory of Open Access Journals (Sweden)

    Carolina Damayanti Marpaung

    2015-06-01

    Full Text Available Immediate loading of dental implant has been researched intensively in the development of Branemark’s early concept of 2 stages implant placement. This was embarked from both patients and practiitioner’s convenience towards a simpler protocol and shorter time frame. Many recent researchers later found that micromotions derived from occlusal loading for a certain degree, instead of resulting a fibrous tissue encapsulation, can enhance the osseointegration process. Dental Implant system enhancement towards maximizing the primary stability held a key factor in Branemark’s concept development. Surgical protocol and implant design was found to give a significant contribution to the prognosis of immediate-loading implants.

  5. Effects of tag and suture type on survival and growth of brown trout with surgically implanted telemetry tags in the wild

    DEFF Research Database (Denmark)

    Jepsen, Niels; Mikkelsen, Jørgen Skole; Koed, Anders

    2008-01-01

    To test the effects of surgical implants with or without external antennae, 188 wild brown trout Salmo trutta, 150 - 290 mm, were tagged and released in a small river in May 2005. After 5 months, 103 of the fish were recaptured and examined. Thus, information on the relative survival, growth and ...

  6. Computerized axial tomography : the tool in osseointegrated dental implants

    International Nuclear Information System (INIS)

    Fernandez-Lopez, Otton

    2002-01-01

    Failure rates in rehabilitations with osseointegrated implants are handled through appropriate radiographic preoperative planning. The appropriate length of the implant without running the risk of a perforation of vital structures, has been determined by a radiographic diagnosis. Computerized and conventional axial tomography have proved to be invaluable elements for pre-surgical evaluation. A radiologic guidance is elaborated to perform a computerized axial tomography (CT) of maxillary bones in totally edentulous patients. Surgical guides are constructed from a wax-up emanated from the information of the CT. The CT has proven to be an radiographic indispensable element to achieve the surgical-prosthetic success in osseointegrated dental implants. The CT has allowed the realization of a precise wax-up for making of surgical guide and a precise temporary prostheses in positioning of osseointegrated implants, with the consequent saving time and money for the rehabilitator and patient [es

  7. Sacroiliac Joint Fusion Using Triangular Titanium Implants vs. Non-Surgical Management: Six-Month Outcomes from a Prospective Randomized Controlled Trial.

    Science.gov (United States)

    Whang, Peter; Cher, Daniel; Polly, David; Frank, Clay; Lockstadt, Harry; Glaser, John; Limoni, Robert; Sembrano, Jonathan

    2015-01-01

    Sacroiliac (SI) joint pain is a prevalent, underdiagnosed cause of lower back pain. SI joint fusion can relieve pain and improve quality of life in patients who have failed nonoperative care. To date, no study has concurrently compared surgical and non-surgical treatments for chronic SI joint dysfunction. We conducted a prospective randomized controlled trial of 148 subjects with SI joint dysfunction due to degenerative sacroiliitis or sacroiliac joint disruptions who were assigned to either minimally invasive SI joint fusion with triangular titanium implants (N=102) or non-surgical management (NSM, n=46). SI joint pain scores, Oswestry Disability Index (ODI), Short-Form 36 (SF-36) and EuroQol-5D (EQ-5D) were collected at baseline and at 1, 3 and 6 months after treatment commencement. Six-month success rates, defined as the proportion of treated subjects with a 20-mm improvement in SI joint pain in the absence of severe device-related or neurologic SI joint-related adverse events or surgical revision, were compared using Bayesian methods. Subjects (mean age 51, 70% women) were highly debilitated at baseline (mean SI joint VAS pain score 82, mean ODI score 62). Six-month follow-up was obtained in 97.3%. By 6 months, success rates were 81.4% in the surgical group vs. 23.9% in the NSM group (difference of 56.6%, 95% posterior credible interval 41.4-70.0%, posterior probability of superiority >0.999). Clinically important (≥15 point) ODI improvement at 6 months occurred in 75% of surgery subjects vs. 27.3% of NSM subjects. At six months, quality of life improved more in the surgery group and satisfaction rates were high. The mean number of adverse events in the first six months was slightly higher in the surgical group compared to the non-surgical group (1.3 vs. 1.0 events per subject, p=0.1857). Six-month follow-up from this level 1 study showed that minimally invasive SI joint fusion using triangular titanium implants was more effective than non-surgical management

  8. Dental implant treatment following trauma: An investigation into the failure to complete Accident Compensation Corporation funded care.

    Science.gov (United States)

    Kennedy, R; Murray, C; Leichter, J

    2016-03-01

    Among other restorative strategies, the Accident Compensation Corporation (ACC) provides benefits for dental implant treatment to replace teeth lost as a result of trauma. While ACC has funded over 15,000 dental implants since 2002, the outcomes of this treatment and patient perceptions of this treatment have not been investigated. The aim of this study was to investigate the perceptions of the dental implant treatment outcomes and reasons for failure to complete restorative treatment in patients who had undergone trauma-related implant surgery funded by ACC between February 2006 and September 2009, but had not completed the prosthetic component of the treatment. A randomly selected sample of 399 patients, who had undergone dental implant surgery but not completed the crown restoration, was identified from the ACC database. These individuals were contacted by mail for expressions of interest and 181 clients were interviewed by telephone. Responses to open-ended questions were entered into an Excel spreadsheet and analysed using a general inductive technique. A common emergent theme was the high level of satisfaction expressed by participants with the implant process, however just under half of those responding felt they had been pushed into having implants and were given the impression that this was the only treatment ACC paid for. The cost of the prosthetic phase of the treatment and surgical complications were identified as the primary reasons why participants failed to complete the restorative phase of treatment, after completing the surgical phase. The results highlighted the need to better inform patients of their treatment options and to allow time for them to process this information before progressing with care. A patient decision tool may help to give greater ownership of the treatment options. Newly implemented protocols to assist dentists to better assess treatment needs may also assist in achieving improvements in perceived treatment outcomes for

  9. Biodegradable Implants in Orthopaedics and Traumatology

    OpenAIRE

    YETKIN, Haluk

    2014-01-01

    Biodegradable implants are an alternative to metallic implants and have the advantage of not being necessary to remove once the fracture has healed. Twenty-two patients with fractures were treated with biodegradable implants. There were osteolysis in eleven patients; however, no serious complication was encountered. Although biodegradable implants are expensive, a second surgical procedure to remove the implants is not necessary, relieving the patient of the related costs and risks.

  10. A 2D panoramic surgical stent imaging: Complete arch mandibular implant fixed prosthesis along with bar supported maxillary over denture

    Directory of Open Access Journals (Sweden)

    Mukesh Kumar Singhal

    2017-01-01

    Full Text Available Successful rehabilitation of a patient should restore function, esthetic, and speech by prosthesis. Treatment modalities vary from patient to patient. Semi-precision attachments and implants offer several advantages over the traditional approach. The aim and objective of this report was to assess a case of a 55-year-old female patient who had lost all her teeth, except maxillary canines #13 and #23 and with severe bone loss in the mandible. Tooth-supported bar attachment was planned for maxilla, and a total of five dental implants were placed in the mandible using a flapless approach aided by radiographic gutta-percha surgical stents over panoramic two-dimensional imaging. Customized, radiographic stents help for the placement of implant in the view of paralleling and flapless surgery, completely. An immediate loading protocol is adopted as from day of the surgery to 6 weeks along with implant supported full arch fixed dentures after 4 months. The outcome of the treatment was impressive, and the patient gave a positive response with superb esthetics and functions.

  11. The effects of local nitroglycerin on the surgical delay procedure in prefabricated flaps by vascular implant in rats Efeitos da nitroglicerina tópica na autonomização de retalhos pré-fabricados por implante vascular em ratos

    Directory of Open Access Journals (Sweden)

    Jairo Zacchê de Sá

    2012-12-01

    Full Text Available PURPOSE: To evaluate the effect of local nitroglycerin on the viable area of a prefabricated flap for vascular implant in rats, and to investigate the surgical delay procedure. METHODS: A femoral pedicle was implanted under the skin of the abdominal wall in forty Wistar rats. The animals were divided into four groups of ten: group 1 - without surgical delay procedure and local nitroglycerin; group 2 - with surgical delay procedure, but without local nitroglycerin; group 3 - without surgical delay procedure, but with local nitroglycerin; and group 4 - with simultaneous surgical delay procedure and local nitroglycerin. The percentages of the viable areas, in relation to the total flap, were calculated using AutoCAD R 14. RESULTS: The mean percentage value of the viable area was 8.9% in the group 1. 49.4% in the group 2; 8.4% in the group 3 and 1.1% in the group 4. There was significant difference between groups 1 and 2 (p=0.005, 1 and 4 (p=0.024, 2 and 3 (p=0.003, 2 and 4 (p=0.001. These results support the hypothesis that the closure of the arterial venous channels is responsible for the phenomenon of surgical delay procedure. CONCLUSION: Local nitroglycerin did not cause an increase in the prefabricated viable flap area by vascular implantation and decreased the viable flap area that underwent delay procedures.OBJETIVO: Avaliar o efeito da nitroglicerina tópica sobre a área viável de um modelo de retalho pré-fabricado por implante vascular em ratos e analisar o mecanismo de autonomização cirúrgica aplicada a retalhos pré-fabricados. MÉTODOS: Foram utilizados 40 ratos Wistar. No primeiro tempo cirúrgico - 20 ratos foram submetidos a implante do pedículo femoral na região subdérmica da parede abdominal, e 20 submetidos à autonomização cirúrgica de retalho cutâneo de parede abdominal e, simultaneamente, implante do pedículo femoral na região subdérmica deste retalho. No segundo tempo - após três semanas e em todos os animais

  12. Role of clinician's experience and implant design on implant stability. An ex vivo study in artificial soft bones.

    Science.gov (United States)

    Romanos, Georgios E; Basha-Hijazi, Abdulaziz; Gupta, Bhumija; Ren, Yan-Fang; Malmstrom, Hans

    2014-04-01

    Clinical experience in implant placement is important in order to prevent implant failures. However, the implant design affects the primary implant stability (PS) especially in poor quality bones. Therefore, the aim of this study was to compare the effect of clinician surgical experience on PS, when placing different type of implant designs. A total of 180 implants (90 parallel walled-P and 90 tapered-T) were placed in freshly slaughtered cow ribs. Bone quality was evaluated by two examiners during surgery and considered as 'type IV' bone. Implants (ø 5 mm, length: 15 mm, Osseotite, BIOMET 3i, Palm Beach Gardens, FL, USA) were placed by three different clinicians (master/I, good/II, non-experienced/III, under direct supervision of a manufacturer representative; 30 implants/group). An independent observer assessed the accuracy of placement by resonance frequency analysis (RFA) with implant stability quotient (ISQ) values. Two-way analysis of variance (ANOVA) and Tukey's post hoc test were used to detect the surgical experience of the clinicians and their interaction and effects of implant design on the PS. All implants were mechanically stable. The mean ISQ values were: 49.57(± 18.49) for the P-implants and 67.07(± 8.79) for the T-implants. The two-way ANOVA showed significant effects of implant design (p bone. © 2012 Wiley Periodicals, Inc.

  13. Implant decontamination during surgical peri-implantitis treatment : a randomized, double-blind, placebo-controlled trial

    NARCIS (Netherlands)

    de Waal, Yvonne C. M.; Raghoebar, Gerry M.; Huddleston Slater, James J. R.; Meijer, Henny J. A.; Winkel, Edwin G.; van Winkelhoff, Arie Jan

    Aim The objective of this randomized, double-blind, placebo-controlled trial was to study the effect of implant surface decontamination with chlorhexidine (CHX)/cetylpyridinium chloride (CPC) on microbiological and clinical parameters. Material & Methods Thirty patients (79 implants) with

  14. Implant decontamination during surgical peri-implantitis treatment : a randomized, double-blind, placebo-controlled trial

    NARCIS (Netherlands)

    de Waal, Yvonne C.M.; Raghoebar, Gerry M; Huddleston Slater, James J R; Meijer, Hendrikus; Winkel, Edwin G; van Winkelhoff, Arie Jan

    AIM: The objective of this randomized, double-blind, placebo-controlled trial was to study the effect of implant surface decontamination with chlorhexidine (CHX)/cetylpyridinium chloride (CPC) on microbiological and clinical parameters. MATERIAL & METHODS: Thirty patients (79 implants) with

  15. SURGICAL TREATMENT OF TROCHANTERIC FRACTURES BY GAMMA3 NAIL

    Directory of Open Access Journals (Sweden)

    Aleksandar Vukićević

    2010-09-01

    Full Text Available Fractures of the greater trochanter rank amongst severe injuries of bone tissue. They occur most frequently in patients over 65 years of age, nearly all of whom are diagnosed with osteoporosis. Non-surgical treatment does not prove to be satisfactory and results in high mortality rate. Surgical treatment is a method of fracture treatment of the trochanteric region, which enables early activation and thus prevents numerous complications in bedridden patients. Gamma3 nails are one of the most state-of-the-art implants for trochanteric fracture fixation. The implant is easy to embed, which does not require a large surgical team. This implant embedding requires the least invasive surgery and complications are rare.This paper describes 47 patients who received surgical treatment and is focused on the first nine months of 2009. The patients were treated at the Orthopaedics Ward of Health Centre Valjevo. They were in their seventies, average age: 72.21 years, with female sex prevailing (63.82%. The outcome was as follows: excellent in 65.96%, good in 17.02% and satisfactory in 4.25% of patients. Surface infections occurred in 6.38% of patients. One implant broke.We had one death outcome in the early post-surgical treatment.Surgical treatment of trochanteric fractures by Gamma3 implants proved very effective as it resulted in few complications and numerous excellent functional and anatomic outcomes. Thus we recommend it as an option when decision on treatment of this type of fractures is made.

  16. Development and Assessment of a 3D-Printed Scaffold with rhBMP-2 for an Implant Surgical Guide Stent and Bone Graft Material: A Pilot Animal Study

    Directory of Open Access Journals (Sweden)

    Ji Cheol Bae

    2017-12-01

    Full Text Available In this study, a new concept of a 3D-printed scaffold was introduced for the accurate placement of an implant and the application of a recombinant human bone morphogenetic protein-2 (rhBMP-2-loaded bone graft. This preliminary study was conducted using two adult beagles to evaluate the 3D-printed polycaprolactone (PCL/β-tricalcium phosphate (β-TCP/bone decellularized extracellular matrix (bdECM scaffold conjugated with rhBMP-2 for the simultaneous use as an implant surgical guide stent and bone graft material that promotes new bone growth. Teeth were extracted from the mandible of the beagle model and scanned by computed tomography (CT to fabricate a customized scaffold that would fit the bone defect. After positioning the implant guide scaffold, the implant was placed and rhBMP-2 was injected into the scaffold of the experimental group. The two beagles were sacrificed after three months. The specimen block was obtained and scanned by micro-CT. Histological analysis showed that the control and experimental groups had similar new bone volume (NBV, % but the experimental group with BMP exhibited a significantly higher bone-to-implant contact ratio (BIC, %. Within the limitations of this preliminary study, a 3D-printed scaffold conjugated with rhBMP-2 can be used simultaneously as an implant surgical guide and a bone graft in a large bone defect site. Further large-scale studies will be needed to confirm these results.

  17. Development and Assessment of a 3D-Printed Scaffold with rhBMP-2 for an Implant Surgical Guide Stent and Bone Graft Material: A Pilot Animal Study

    Science.gov (United States)

    Bae, Ji Cheol; Lee, Jin-Ju; Shim, Jin-Hyung; Park, Keun-Ho; Lee, Jeong-Seok; Bae, Eun-Bin; Choi, Jae-Won; Huh, Jung-Bo

    2017-01-01

    In this study, a new concept of a 3D-printed scaffold was introduced for the accurate placement of an implant and the application of a recombinant human bone morphogenetic protein-2 (rhBMP-2)-loaded bone graft. This preliminary study was conducted using two adult beagles to evaluate the 3D-printed polycaprolactone (PCL)/β-tricalcium phosphate (β-TCP)/bone decellularized extracellular matrix (bdECM) scaffold conjugated with rhBMP-2 for the simultaneous use as an implant surgical guide stent and bone graft material that promotes new bone growth. Teeth were extracted from the mandible of the beagle model and scanned by computed tomography (CT) to fabricate a customized scaffold that would fit the bone defect. After positioning the implant guide scaffold, the implant was placed and rhBMP-2 was injected into the scaffold of the experimental group. The two beagles were sacrificed after three months. The specimen block was obtained and scanned by micro-CT. Histological analysis showed that the control and experimental groups had similar new bone volume (NBV, %) but the experimental group with BMP exhibited a significantly higher bone-to-implant contact ratio (BIC, %). Within the limitations of this preliminary study, a 3D-printed scaffold conjugated with rhBMP-2 can be used simultaneously as an implant surgical guide and a bone graft in a large bone defect site. Further large-scale studies will be needed to confirm these results. PMID:29258172

  18. Middle ear implants

    Directory of Open Access Journals (Sweden)

    K S Gangadhara Somayaji

    2013-01-01

    Full Text Available Hearing loss is becoming more common in the society living in cities with lot of background noise around, and frequent use of gadgets like mobile phones, MP3s, and IPods are adding to the problem. The loss may involve the conductive or perceptive pathway. Majority of the patients with conductive hearing loss will revert back to normal hearing levels with medical and/or surgical treatment. However, in sensorineural hearing loss, many factors are involved in the management. Though traditionally hearing aids in various forms are the most commonly used modality in managing these patients, there are some drawbacks associated with them. Implantable middle ear amplifiers represent the most recent breakthrough in the management of hearing loss. Middle ear implants are surgically implanted electronic devices that aim to correct hearing loss by stimulating the ossicular chain or middle ear. Of late, they are also being used in the management of congenital conductive hearing loss and certain cases of chronic otitis media with residual hearing loss. The article aims to provide general information about the technology, indications and contraindications, selection of candidates, available systems, and advantages of middle ear implants. (MEI

  19. Linguine sign at MR imaging: does it represent the collapsed silicone implant shell?

    Science.gov (United States)

    Gorczyca, D P; DeBruhl, N D; Mund, D F; Bassett, L W

    1994-05-01

    One intact and one ruptured single-lumen implant were surgically placed in a rabbit. Magnetic resonance (MR) imaging was performed before and after surgical removal, and the ruptured implant was imaged after removal of the implant shell. Multiple curvilinear hypointense lines (linguine sign) were present in the MR images of the ruptured implant and of the implant shell alone immersed in saline solution but not in the image of the free silicone. The collapsed implant shell in a ruptured silicone implant does cause the linguine sign.

  20. Tricks of the trade: time management tips for newly qualified doctors.

    Science.gov (United States)

    Offiah, Gozie; Doherty, Eva

    2018-03-01

    The transition from medical student to doctor is an important milestone. The discovery that their time is no longer their own and that the demands of their job are greater than the time they have available is extremely challenging. At a recent surgical boot camp training programme, 60 first-year surgical trainees who had just completed their internship were invited to reflect on the lessons learnt regarding effective time management and to recommend tips for their newly qualified colleagues. They were asked to identify clinical duties that were considered urgent and important using the time management matrix and the common time traps encountered by newly qualified doctors. The surgical trainees identified several practical tips that ranged from writing a priority list to working on relationships within the team. These tips are generic and so applicable to all newly qualified medial doctors. We hope that awareness of these tips from the outset as against learning them through experience will greatly assist newly qualified doctors. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. [Morphologic feature and cochlear implant surgical approach for cochlear modiolus deficiency].

    Science.gov (United States)

    Zhang, Daoxing

    2014-09-01

    To review the classification of cochlear modiolus deficiency and decision on surgical approach for above case,in order to provide mastery for cochlear implant (CI) indication. Basing on temporal bone HRCT pre-operation, CI subjects with modiolus deficiency were defined as following groups: (1) deficiency caused by cochlear dysplasia (Mondini malformation); (2) deficiency caused by dysplasia of cochlear and vestibule (Common cavity malformation); (3) deficiency caused by absence of internal acoustic meatus fundus (IP-III malformation). Three types of surgical approach were utilized: type I, electrode array was introduced through facial recess, enlarged the round window, type II, opened the surface of chchlea, electrode array was introduced through facial recess, fenestration on posterior promontory and then inserted around lateral wall of inner-cochlear cavity. type III, electrode array was introduce through fenestration of lateral semicircular canal and then placed close to the bony wall of common cavity. One hundred and sixty-six cochlear modiolus deficiency cases were identified into 3 groups as following: 135 Mondini malformation cases into group a, 18 common cavity malformation cases into group b, and 13 IP-III malformation cases into group c. Surgical approach: type I were used in 136 cases (123 Mondini cases and 13 IP-III cases), while approach type II in 12 cases (12 Mondini cases), and approach type III in 18 cases (18 common cavity cases). Income post-operation of CI: For group a (Mondini malformation), post-activation mean hearing threshold in sound field was 65 dB, speech recognition score is 95% (single finals test) and 25% (signal initials test), while it was 80 dB, 60% and 0 for group b (Conmon cavity malformation), and it was 55 dB, 100% and 45% for group c (IP-III malformation). The income of speech recognition score for cochlear modiolus deficiency was relatively poor, group b was worst and group c was best, while group a moderate.

  2. Retrospective analysis of dental implants placed and restored by advanced prosthodontic residents.

    Science.gov (United States)

    Barias, Pamela A; Lee, Damian J; Yuan, Judy Chia-Chun; Sukotjo, Cortino; Campbell, Stephen D; Knoernschild, Kent L

    2013-02-01

    The purposes of this retrospective clinical review were to: (1) describe the demographics of implant patients, types of implant treatment and implant-supported prostheses in an Advanced Education in Prosthodontic Program, (2) evaluate the survival rate of dental implants placed by prosthodontic residents from 2006 to 2008, and (3) analyze the relationship between resident year of training and implant survival rate. All patients who received dental implants placed by prosthodontic residents from January 2006 to October of 2008 in the Advanced Prosthodontic Program at the University of Illinois at Chicago College of Dentistry were selected for this study. Age, gender, implant diameter, length, implant locations, surgical and restorative detail, and year of prosthodontic residency training were collected and analyzed. Life-table and Kaplan-Meier survival analyses were performed based on implants overall, locations, year of training, and use of a computer-generated surgical guide. A Logrank statistic was performed between implant survival and year of prosthodontic residency training, location, and use of computer-generated surgical guide (α= 0.05). Three hundred and six implants were placed, and of these, seven failed. Life-table and Kaplan-Meier analyses computed a cumulative survival rate (CSR) of 97% for overall implants and implants placed with a computer-generated surgical guide. No statistical difference was found in implant survival rates as a function of year of training (P= 0.85). Dental implants placed by prosthodontic residents had a CSR comparable to previously published studies by other specialties. The year of prosthodontic residency training and implant failure rate did not have any significant relationship. © 2012 by the American College of Prosthodontists.

  3. Sub-meninges implantation reduces immune response to neural implants.

    Science.gov (United States)

    Markwardt, Neil T; Stokol, Jodi; Rennaker, Robert L

    2013-04-15

    Glial scar formation around neural interfaces inhibits their ability to acquire usable signals from the surrounding neurons. To improve neural recording performance, the inflammatory response and glial scarring must be minimized. Previous work has indicated that meningeally derived cells participate in the immune response, and it is possible that the meninges may grow down around the shank of a neural implant, contributing to the formation of the glial scar. This study examines whether the glial scar can be reduced by placing a neural probe completely below the meninges. Rats were implanted with sets of loose microwire implants placed either completely below the meninges or implanted conventionally with the upper end penetrating the meninges, but not attached to the skull. Histological analysis was performed 4 weeks following surgical implantation to evaluate the glial scar. Our results found that sub-meninges implants showed an average reduction in reactive astrocyte activity of 63% compared to trans-meninges implants. Microglial activity was also reduced for sub-meninges implants. These results suggest that techniques that isolate implants from the meninges offer the potential to reduce the encapsulation response which should improve chronic recording quality and stability. Published by Elsevier B.V.

  4. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma

    OpenAIRE

    Wang, Rui; Bi, Chun-Chao; Lei, Chun-Ling; Sun, Wen-Tao; Wang, Shan-Shan; Dong, Xiao-Juan

    2014-01-01

    AIM:To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL) implantation.METHODS:Non-comparative retrospective observational case series. Participants:30 cases (30 eyes) of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Opht...

  5. Trabeculectomy with Ex-PRESS implant versus Ahmed glaucoma valve implantation-a comparative study

    Science.gov (United States)

    Waisbourd, Michael; Fischer, Naomi; Shalev, Hadas; Spierer, Oriel; Ben Artsi, Elad; Rachmiel, Rony; Shemesh, Gabi; Kurtz, Shimon

    2016-01-01

    AIM To compare the surgical outcomes of trabeculectomy with Ex-PRESS implant and Ahmed glaucoma valve (AGV) implantation. METHODS Patients who underwent trabeculectomy with Ex-PRESS implants or AGV implantation separately were included in this retrospective chart review. Main outcome measures were surgical failure and complications. Failure was defined as intraocular pressure (IOP) >21 mm Hg or glaucoma, or loss of light perception. Eyes that had not failed were considered as complete success if they did not required supplemental medical therapy. RESULTS A total of 64 eyes from 57 patients were included: 31 eyes in the Ex-PRESS group and 33 eyes in the AGV group. The mean follow-up time was 2.6±1.1y and 3.3±1.6y, respectively. Patients in the AGV group had significantly higher baseline mean IOP (P=0.005), lower baseline mean visual acuity (VA) (P=0.02), and higher proportion of patients with history of previous trabeculectomy (Pglaucoma surgeries. Therefore, the results are limited to the cohort included in this study. PMID:27803857

  6. Surgically Implanted JSATS Micro-Acoustic Transmitters Effects on Juvenile Chinook Salmon and Steelhead Tag Expulsion and Survival, 2010

    Energy Technology Data Exchange (ETDEWEB)

    Woodley, Christa M.; Carpenter, Scott M.; Carter, Kathleen M.; Wagner, Katie A.; Royer, Ida M.; Knox, Kasey M.; Kim, Jin A.; Gay, Marybeth E.; Weiland, Mark A.; Brown, Richard S.

    2011-09-16

    The purpose of this study was to evaluate survival model assumptions associated with a concurrent study - Acoustic Telemetry Evaluation of Dam Passage Survival and Associated Metrics at John Day, The Dalles, and Bonneville Dams, 2010 by Thomas Carlson and others in 2010 - in which the Juvenile Salmonid Acoustic Telemetry System (JSATS) was used to estimate the survival of yearling and subyearling Chinook salmon (Oncorhynchus tshawytscha) and steelhead (O. mykiss) migrating through the Federal Columbia River Power System (FCRPS). The micro-acoustic transmitter used in these studies is the smallest acoustic transmitter model to date (12 mm long x 5 mm wide x 4 mm high, and weighing 0.43 g in air). This study and the 2010 study by Carlson and others were conducted by researchers from the Pacific Northwest National Laboratory and the University of Washington for the U.S. Army Corps of Engineers, Portland District, to meet requirements set forth by the 2008 FCRPS Biological Opinion. In 2010, we compared survival, tag burden, and tag expulsion in five spring groups of yearling Chinook salmon (YCH) and steelhead (STH) and five summer groups of subyearling Chinook salmon (SYC) to evaluate survival model assumptions described in the concurrent study. Each tagging group consisted of approximately 120 fish/species, which were collected and implanted on a weekly basis, yielding approximately 600 fish total/species. YCH and STH were collected and implanted from late April to late May (5 weeks) and SYC were collected and implanted from mid-June to mid-July (5 weeks) at the John Day Dam Smolt Monitoring Facility. The fish were collected once a week, separated by species, and assigned to one of three treatment groups: (1) Control (no surgical treatment), (2) Sham (surgical implantation of only a passive integrated transponder [PIT] tag), and (3) Tagged (surgical implantation of JSATS micro-acoustic transmitter [AT] and PIT tags). The test fish were held for 30 days in indoor

  7. Performance Assessment of Suture Type in Juvenile Chinook Salmon Surgically Implanted with Acoustic Transmitters

    Energy Technology Data Exchange (ETDEWEB)

    Deters, Katherine A.; Brown, Richard S.; Carter, Kathleen M.; Boyd, James W.

    2009-02-27

    The objective of this study was to determine the best overall suture material to close incisions from the surgical implantation of Juvenile Salmon Acoustic Telemetry System (JSATS) acoustic microtransmitters in subyearling Chinook salmon Oncorhynchus tshawytscha. The effects of seven suture materials, four surgeons, and two water temperatures on suture retention, incision openness, tag retention, tissue inflammation, and tissue ulceration were quantified. The laboratory study, conducted by researchers at the Pacific Northwest National Laboratory, supports a larger effort under way for the U.S. Army Corps of Engineers, Portland District, aimed at determining the suitability of acoustic telemetry for estimating short- and longer-term (30-60 days) juvenile-salmonid survival at Columbia and Snake River dams and through the lower Columbia River.

  8. 3D Printed, Customized Cranial Implant for Surgical Planning

    Science.gov (United States)

    Bogu, Venkata Phanindra; Ravi Kumar, Yennam; Asit Kumar, Khanra

    2018-06-01

    The main objective of the present work is to model cranial implant and printed in FDM machine (printer model used: mojo). Actually this is peculiar case and the skull has been damaged in frontal, parietal and temporal regions and a small portion of frontal region damaged away from saggital plane, complexity is to fill this frontal region with proper curvature. The Patient CT-data (Number of slices was 381 and thickness of each slice is 0.488 mm) was processed in mimics14.1 software, mimics file was sent to 3-matic software and calculated thickness of skull at different sections where cranial implant is needed then corrected the edges of cranial implant to overcome CSF (cerebrospinal fluid) leakage and proper fitting. Finally the implant average thickness is decided as 2.5 mm and printed in FDM machine with ABS plastic.

  9. Surface modifications of dental implants.

    Science.gov (United States)

    Stanford, C M

    2008-06-01

    Dental implant surface technologies have been evolving rapidly to enhance a more rapid bone formation on their surface and hold a potential to increase the predictability of expedited implant therapy. While implant outcomes have become highly predictable, there are sites and conditions that result in elevated implant loss. This paper reviews the impact of macro-retentive features which includes approaches to surface oxide modification, thread design, press-fit and sintered-bead technologies to increase predictability of outcomes. Implant designs that lead to controlled lateral compression of the bone can improve primary stability as long as the stress does not exceed the localized yield strength of the cortical bone. Some implant designs have reduced crestal bone loss by use of multiple cutting threads that are closely spaced, smoothed on the tip but designed to create a hoop-stress stability of the implant as it is completely seated in the osteotomy. Following the placement of the implant, there is a predictable sequence of bone turnover and replacement at the interface that allows the newly formed bone to adapt to microscopic roughness on the implant surface, and on some surfaces, a nanotopography (<10(-9) m scale) that has been shown to preferably influence the formation of bone. Newly emerging studies show that bone cells are exquisitely sensitive to these topographical features and will upregulate the expression of bone related genes for new bone formation when grown on these surfaces. We live in an exciting time of rapid changes in the modalities we can offer patients for tooth replacement therapy. Given this, it is our responsibility to be critical when claims are made, incorporate into our practice what is proven and worthwhile, and to continue to support and provide the best patient care possible.

  10. Impact of cone-beam computed tomography on implant planning and on prediction of implant size

    International Nuclear Information System (INIS)

    Pedroso, Ludmila Assuncao de Mello; Silva, Maria Alves Garcia Santos; Garcia, Robson Rodrigues; Leles, Jose Luiz Rodrigues; Leles, Claudio Rodrigues

    2013-01-01

    The aim was to investigate the impact of cone-beam computed tomography (CBCT) on implant planning and on prediction of final implant size. Consecutive patients referred for implant treatment were submitted to clinical examination, panoramic (PAN) radiography and a CBCT exam. Initial planning of implant length and width was assessed based on clinical and PAN exams, and final planning, on CBCT exam to complement diagnosis. The actual dimensions of the implants placed during surgery were compared with those obtained during initial and final planning, using the McNemmar test (p 0.05). It was concluded that CBCT improves the ability of predicting the actual implant length and reduces inaccuracy in surgical dental implant planning. (author)

  11. Survival of dental implants placed in sites of previously failed implants.

    Science.gov (United States)

    Chrcanovic, Bruno R; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-11-01

    To assess the survival of dental implants placed in sites of previously failed implants and to explore the possible factors that might affect the outcome of this reimplantation procedure. Patients that had failed dental implants, which were replaced with the same implant type at the same site, were included. Descriptive statistics were used to describe the patients and implants; survival analysis was also performed. The effect of systemic, environmental, and local factors on the survival of the reoperated implants was evaluated. 175 of 10,096 implants in 98 patients were replaced by another implant at the same location (159, 14, and 2 implants at second, third, and fourth surgeries, respectively). Newly replaced implants were generally of similar diameter but of shorter length compared to the previously placed fixtures. A statistically significant greater percentage of lost implants were placed in sites with low bone quantity. There was a statistically significant difference (P = 0.032) in the survival rates between implants that were inserted for the first time (94%) and implants that replaced the ones lost (73%). There was a statistically higher failure rate of the reoperated implants for patients taking antidepressants and antithrombotic agents. Dental implants replacing failed implants had lower survival rates than the rates reported for the previous attempts of implant placement. It is suggested that a site-specific negative effect may possibly be associated with this phenomenon, as well as the intake of antidepressants and antithrombotic agents. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Impact of dental implant insertion method on the peri-implant bone tissue: Experimental study

    Directory of Open Access Journals (Sweden)

    Stamatović Novak

    2013-01-01

    Full Text Available Background/Aim. The function of dental implants depends on their stability in bone tissue over extended period of time, i.e. on osseointegration. The process through which osseointegration is achieved depends on several factors, surgical insertion method being one of them. The aim of this study was to histopathologically compare the impact of the surgical method of implant insertion on the peri-implant bone tissue. Methods. The experiment was performed on 9 dogs. Eight weeks following the extraction of lower premolars implants were inserted using the one-stage method on the right mandibular side and two-stage method on the left side. Three months after implantation the animals were sacrificed. Three distinct regions of bone tissue were histopathologically analyzed, the results were scored and compared. Results. In the specimens of one-stage implants increased amount of collagen fibers was found in 5 specimens where tissue necrosis was also observed. Only moderate osteoblastic activity was found in 3 sections. The analysis of bone-to-implant contact region revealed statistically significantly better results regarding the amount of collagen tissue fibers for the implants inserted in the two-stage method (Wa = 59 105, α = 0.05. No necrosis and osteoblastic activity were observed. Conclusion. Better results were achieved by the two-stage method in bone-to-implant contact region regarding the amount of collagen tissue, while the results were identical regarding the osteoblastic activity and bone tissue necrosis. There was no difference between the methods in the bone-implant interface region. In the bone tissue adjacent to the implant the results were identical regarding the amount of collagen tissue, osteoblastic reaction and bone tissue necrosis, while better results were achieved by the two-stage method regarding the number of osteocytes.

  13. Most common surgical mistakes with treatment of prosthetic joint infections

    Directory of Open Access Journals (Sweden)

    Boštjan Kocjančič

    2014-08-01

    Full Text Available The treatment of infections of orthopedic implants is often difficult and complex, although the chances of successful treatment with properly selected diagnostics, surgical and antibiotic treatment protocol have recently increased significantly. Surgical treatment is a key stone factor in the treatment of infections of orthopedic implants and any errors in it often lead to worse clinical outcomes. The most important and frequent surgical errors include: conservative treatment of periprothetic infections with antibiotics only, to-late surgical revision, insufficient debridement during surgical revision, inadequate intraoperative samples for bacteriological and histological analysis. It is important to have and to follow proper treatment algorithm for periprosthetic joint infection. In this work we present the listed surgical and most illustrative key errors.

  14. Surgical management of fractured orthodontic mini- implant- a case report.

    Science.gov (United States)

    Desai, Manthan; Jain, Anoop; Sumra, Nida

    2015-01-01

    The idea of absolute anchorage has always been an elusive goal for clinicians. Orthodontic mini-implants or temporary anchorage devices allow tooth movements previously thought to be impossible or difficult. Although extensive literature exists on use of temporary anchorage devices, their failures have been hardly focused upon, especially implant fracture. The following case report describes successful management of fractured orthodontic mini-implant.

  15. Influence of surgical implantation angle of left ventricular assist device outflow graft and management of aortic valve opening on the risk of stroke in heart failure patients

    Science.gov (United States)

    Chivukula, V. Keshav; McGah, Patrick; Prisco, Anthony; Beckman, Jennifer; Mokadam, Nanush; Mahr, Claudius; Aliseda, Alberto

    2016-11-01

    Flow in the aortic vasculature may impact stroke risk in patients with left ventricular assist devices (LVAD) due to severely altered hemodynamics. Patient-specific 3D models of the aortic arch and great vessels were created with an LVAD outflow graft at 45, 60 and 90° from centerline of the ascending aorta, in order to understand the effect of surgical placement on hemodynamics and thrombotic risk. Intermittent aortic valve opening (once every five cardiac cycles) was simulated and the impact of this residual native output investigated for the potential to wash out stagnant flow in the aortic root region. Unsteady CFD simulations with patient-specific boundary conditions were performed. Particle tracking for 10 cardiac cycles was used to determine platelet residence times and shear stress histories. Thrombosis risk was assessed by a combination of Eulerian and Lagrangian metrics and a newly developed thrombogenic potential metric. Results show a strong influence of LVAD outflow graft angle on hemodynamics in the ascending aorta and consequently on stroke risk, with a highly positive impact of aortic valve opening, even at low frequencies. Optimization of LVAD implantation and management strategies based on patient-specific simulations to minimize stroke risk will be presented

  16. Analysis of submerged implant towards mastication load using 3D finite element method (FEM)

    OpenAIRE

    Widia Hafsyah Sumarlina Ritonga; Janti Rusjanti; Nunung Rusminah; Aldilla Miranda; Tatacipta Dirgantara

    2016-01-01

    Introduction: The surgical procedure for implantation of a surgical implant comprising a stage for the implant design nonsubmerged and two stages for submerged. Submerged implant design often used in Faculty of Dentistry Universitas Padjadjaran because it is safer in achieving osseointegration. This study was conducted to evaluate the failure of dental implant based on location and the value of internal tensiones as well as supporting tissues when given mastication load by using the 3D Finite...

  17. Single Sitting Surgical Treatment of Generalized Aggressive Periodontitis Using GTR Technique and Immediate Implant Placement with 10-Year Follow-Up

    Directory of Open Access Journals (Sweden)

    Fatme Mouchref Hamasni

    2018-01-01

    Full Text Available This case report exhibits a patient with generalized aggressive periodontitis who has been under maintenance for the past 12 years after being surgically treated in a single sitting and restored with dental implants. A 41-year-old systemically healthy male patient presented complaining of lower anterior teeth mobility and pain in the upper right quadrant. After clinical and radiographic examination, the upper right molars and lower anterior incisors were deemed unrestorable. Covered by doxycycline, the patient received a nonsurgical periodontal treatment. Three weeks later, teeth extraction, immediate implant placement, immediate nonloading provisional prosthesis, and a guided tissue regeneration were performed at indicated areas in a single sitting. The clinical decisions were based on patient compliance, the status of the existing periodontal tissues, and the prognosis of the remaining teeth. During the 12-year follow-up period, no residual pockets were observed and there was no exacerbation of the inflammatory condition. Marginal bone stability is present on all implants. For aggressive periodontal disease, a high risk of relapse as well as limited success and survival of dental implants should be considered. This case shows proper containment of the disease based on appropriate treatment planning and a strict maintenance program.

  18. Advancing the surgical implantation of electronic tags in fish: a gap analysis and research agenda based on a review of trends in intracoelomic tagging effects studies

    Energy Technology Data Exchange (ETDEWEB)

    Cooke, Steven J.; Woodley, Christa M.; Eppard, M. B.; Brown, Richard S.; Nielsen, Jennifer L.

    2011-03-08

    Early approaches to surgical implantation of electronic tags in fish were often through trial and error, however, in recent years there has been an interest in using scientific research to identify techniques and procedures that improve the outcome of surgical procedures and determine the effects of tagging on individuals. Here we summarize the trends in 108 peer-reviewed electronic tagging effect studies focused on intracoleomic implantation to determine opportunities for future research. To date, almost all of the studies have been conducted in freshwater, typically in laboratory environments, and have focused on biotelemetry devices. The majority of studies have focused on salmonids, cyprinids, ictalurids and centrarchids, with a regional bias towards North America, Europe and Australia. Most studies have focused on determining whether there is a negative effect of tagging relative to control fish, with proportionally fewer that have contrasted different aspects of the surgical procedure (e.g., methods of sterilization, incision location, wound closure material) that could advance the discipline. Many of these studies included routine endpoints such as mortality, growth, healing and tag retention, with fewer addressing sublethal measures such as swimming ability, predator avoidance, physiological costs, or fitness. Continued research is needed to further elevate the practice of electronic tag implantation in fish in order to ensure that the data generated are relevant to untagged conspecifics (i.e., no long-term behavioural or physiological consequences) and the surgical procedure does not impair the health and welfare status of the tagged fish. To that end, we advocate for i) rigorous controlled manipulations based on statistical designs that have adequate power, account for inter-individual variation, and include controls and shams, ii) studies that transcend the laboratory and the field with more studies in marine waters, iii) incorporation of knowledge and

  19. Percutaneous implantation of thoracic and abdominal aortic prostheses in patients at high surgical risk

    Directory of Open Access Journals (Sweden)

    Juan C Ortiz

    2013-02-01

    intraluminal stent implantation is an alternative. Objective: to analyze the impact of percutaneous implantation of aortic stents in high-risk surgical patients with a minimum of one y ear follow-up. Method: Descriptive study conducted from December 2005 to March 2010 which included 125 patients with thoracic or abdominal aortic aneurysm, meeting surgical criteria by its diameter and that were rejected from surgery due to their high risk. The outcomes were intraoperative death from any cause and aneurysm-related at one, six and twelve months. Complications were defined as vascular occurred during the first thirty days. Results: Abdominal aneurysm was more frequent (70.4%. The overall mortality at 25.7 months follow-up was 14.8%. Of this percentage, 5.2% died from causes related to the aneurysm. One patient died during surgery. 4.3% were reoperated for leaks. There was higher aneurysm-related mortality in the thoracic (14.7 vs. 1.2% p = 0.003 and a trend in those of larger diameter (6.9 vs. 5.7 cm p = 0.210. There was no association between mortality and diabetes mellitus, smoking, heart disease, hypertension or dyslipidemia. Conclusions: aneurysm-related mortality in patients undergoing aortic stent graft is low. Mortality was associated with thoracic aneurysm and to its greater diameter. Complications did not imply an increase in mortality. In conclusion, in patients with aortic aneurysm and high surgical risk rejected for open surgery, percutaneous approach is a safe and effective treatment in a medium-term follow-up.

  20. Pneumococcal meningitis post-cochlear implantation: preventative measures.

    Science.gov (United States)

    Wei, Benjamin P C; Shepherd, Robert K; Robins-Browne, Roy M; Clark, Graeme M; O'Leary, Stephen J

    2010-11-01

    Both clinical data and laboratory studies demonstrated the risk of pneumococcal meningitis post-cochlear implantation. This review examines strategies to prevent post-implant meningitis. Medline/PubMed database; English articles after 1980. Search terms: cochlear implants, pneumococcus meningitis, streptococcus pneumonia, immunization, prevention. Narrative review. All articles relating to post-implant meningitis without any restriction in study designs were assessed and information extracted. The presence of inner ear trauma as a result of surgical technique or cochlear implant electrode array design was associated with a higher risk of post-implant meningitis. Laboratory data demonstrated the effectiveness of pneumococcal vaccination in preventing meningitis induced via the hematogenous route of infection. Fibrous sealing around the electrode array at the cochleostomy site, and the use of antibiotic-coated electrode array reduced the risk of meningitis induced via an otogenic route. The recent scientific data support the U.S. Food and Drug Administration recommendation of pneumococcal vaccination for the prevention of meningitis in implant recipients. Nontraumatic cochlear implant design, surgical technique, and an adequate fibrous seal around the cochleostomy site further reduce the risk of meningitis. Copyright © 2010 American Academy of Otolaryngology–Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  1. Tissue engineering as a potential alternative or adjunct to surgical reconstruction in treating pelvic organ prolapse

    DEFF Research Database (Denmark)

    Boennelycke, M; Gräs, Søren; Lose, G

    2013-01-01

    Cell-based tissue engineering strategies could potentially provide attractive alternatives to surgical reconstruction of native tissue or the use of surgical implants in treating pelvic organ prolapse (POP).......Cell-based tissue engineering strategies could potentially provide attractive alternatives to surgical reconstruction of native tissue or the use of surgical implants in treating pelvic organ prolapse (POP)....

  2. Cochlear implants and medical tourism.

    Science.gov (United States)

    McKinnon, Brian J; Bhatt, Nishant

    2010-09-01

    To compare the costs of medical tourism in cochlear implant surgery performed in India as compared to the United States. In addition, the cost savings of obtaining cochlear implant surgery in India were compare d to those of other surgical interventions obtained as a medical tourist. Searches were conducted on Medline and Google using the search terms: 'medical tourism', 'medical offshoring', 'medical outsourcing', 'cochlear implants' and 'cochlear implantation'. The information regarding cost of medical treatment was obtained from personal communication with individuals familiar with India's cochlear implantation medical tourism industry. The range of cost depended on length of stay as well as the device chosen. Generally the cost, inclusive of travel, surgery and device, was in the range of $21,000-30,000, as compared to a cost range of $40,000-$60,000 in the US. With the escalating cost of healthcare in the United States, it is not surprising that some patients would seek to obtain surgical care overseas at a fraction of the cost. Participants in medical tourism often have financial resources, but lack health insurance coverage. While cardiovascular and orthopedic surgery performed outside the United States in India at centers that cater to medical tourists are often performed at one-quarter to one-third of the cost that would have been paid in the United States, the cost differential for cochlear implants is not nearly as favorable.

  3. Analysis of edentulous maxillae using computed tomography and panoramic radiography in the surgical planning of dental implants

    International Nuclear Information System (INIS)

    Sahuinco, Humberto Lazaro Choquepuma; Souza, Ricardo Pires de

    2006-01-01

    Objective: to determine agreement of three observers on analysis of linear measurements of edentulous maxillae using computed tomography and panoramic radiography in the surgical planning of dental implants. Material and Method: the samples of 17 patients were analyzed with computed tomography and panoramic radiography. Linear measurements obtained from both methods were made at the following anatomical points: left tuberosity, left canine pillar, incisive foramen, right canine pillar and right tuberosity. Kendall's W test was applied to assess the level of agreement. Results: measured W-values from the samples of the anatomical points mentioned above, analyzed with panoramic radiography and computed tomography, were: 0.75 and 0.901; 0.916 and 0.956; 0.843 and 0.964; 0.963 and 0.931; 0.95 and 0.89 respectively. Statistical analysis showed that there was no statistically significant difference. Conclusion: agreement occurred in the measurements of variables.That means that if the three observers were to select an implant to be placed in each of the anatomical regions studied, there would be a good chance whey would choose the same type. (author)

  4. Management of peri-implant infections

    Directory of Open Access Journals (Sweden)

    K L Vandana

    2015-01-01

    Full Text Available The ever-increasing popularity of dental implants in recent years has been associated with the reported incidence of short-term and long-term complications such as peri-implant mucositis and peri-implantitis. Therapies proposed for treating peri-implantitis are based on the evidence available for the treatment of periodontitis, and are aimed at reducing the bacterial load within peri-implant pockets and decontaminating implant surfaces, and, in some cases, attempting afterward to bring about bone regeneration. The treatment of peri-implant infections comprises conservative (nonsurgical and surgical approaches. This paper reviews various treatment strategies used for the treatment of peri-implant diseases. There are many approaches suggested by various authors for the treatment of peri-implant diseases, but there is no “ideal peri-implant therapy” that has been described in the literature. There is no consensus regarding the treatment protocol as the studies conducted so far have had varying study designs, small sample sizes, and short follow-up periods.

  5. Intracapsular implant rupture: MR findings of incomplete shell collapse.

    Science.gov (United States)

    Soo, M S; Kornguth, P J; Walsh, R; Elenberger, C; Georgiade, G S; DeLong, D; Spritzer, C E

    1997-01-01

    The objective of this study was to determine the frequency and significance of the MR findings of incomplete shell collapse for detecting implant rupture in a series of surgically removed breast prostheses. MR images of 86 breast implants in 44 patients were studied retrospectively and correlated with surgical findings at explantation. MR findings included (a) complete shell collapse (linguine sign), 21 implants; (b) incomplete shell collapse (subcapsular line sign, teardrop sign, and keyhole sign), 33 implants; (c) radial folds, 31 implants; and (d) normal, 1 implant. The subcapsular line sign was seen in 26 implants, the teardrop sign was seen in 27 implants, and the keyhole sign was seen in 23 implants. At surgery, 48 implants were found to be ruptured and 38 were intact. The MR findings of ruptured implants showed signs of incomplete collapse in 52% (n = 25), linguine sign in 44% (n = 21), and radial folds in 4% (n = 2). The linguine sign perfectly predicted implant rupture, but sensitivity was low. Findings of incomplete shell collapse improved sensitivity and negative predictive values, and the subcapsular line sign produced a significant incremental increase in predictive ability. MRI signs of incomplete shell collapse were more common than the linguine sign in ruptured implants and are significant contributors to the high sensitivity and negative predictive values of MRI for evaluating implant integrity.

  6. Three-Dimensional Printing Surgical Applications.

    Science.gov (United States)

    AlAli, Ahmad B; Griffin, Michelle F; Butler, Peter E

    2015-01-01

    Three-dimensional printing, a technology used for decades in the industrial field, gains a lot of attention in the medical field for its potential benefits. With advancement of desktop printers, this technology is accessible and a lot of research is going on in the medical field. To evaluate its application in surgical field, which may include but not limited to surgical planning, surgical education, implants, and prosthesis, which are the focus of this review. Research was conducted by searching PubMed, Web of science, and other reliable sources. We included original articles and excluded articles based on animals, those more than 10 years old, and those not in English. These articles were evaluated, and relevant studies were included in this review. Three-dimensional printing shows a potential benefit in surgical application. Printed implants were used in patient in a few cases and show successful results; however, longer follow-up and more trials are needed. Surgical and medical education is believed to be more efficient with this technology than the current practice. Printed surgical instrument and surgical planning are also believed to improve with three-dimensional printing. Three-dimensional printing can be a very powerful tool in the near future, which can aid the medical field that is facing a lot of challenges and obstacles. However, despite the reported results, further research on larger samples and analytical measurements should be conducted to ensure this technology's impact on the practice.

  7. Treatment Alternatives to Negotiate Peri-Implantitis

    Directory of Open Access Journals (Sweden)

    Eli E. Machtei

    2014-01-01

    Full Text Available Peri-implant diseases are becoming a major health issue in dentistry. Despite the magnitude of this problem and the potential grave consequences, commonly acceptable treatment protocols are missing. Hence, the present paper reviews the literature treatment of peri-implantitis in order to explore their benefits and limitations. Treatment of peri-implantitis may include surgical and nonsurgical approaches, either individually or combined. Nonsurgical therapy is aimed at removing local irritants from the implants’ surface with or without surface decontamination and possibly some additional adjunctive therapies agents or devices. Systemic antibiotics may also be incorporated. Surgical therapy is aimed at removing any residual subgingival deposits and additionally reducing the peri-implant pockets depth. This can be done alone or in conjunction with either osseous respective approach or regenerative approach. Finally, if all fails, explantation might be the best alternative in order to arrest the destruction of the osseous structure around the implant, thus preserving whatever is left in this site for future reconstruction. The available literature is still lacking with large heterogeneity in the clinical response thus suggesting possible underlying predisposing conditions that are not all clear to us. Therefore, at present time treatment of peri-implantitis should be considered possible but not necessarily predictable.

  8. Carbon offers advantages as implant material in human body

    Science.gov (United States)

    Benson, J.

    1969-01-01

    Because of such characteristics as high strength and long-term biocompatability, aerospace carbonaceous materials may be used as surgical implants to correct pathological conditions in the body resulting from disease or injury. Examples of possible medical uses include bone replacement, implantation splints and circulatory bypass implants.

  9. Development and Assessment of a 3D-Printed Scaffold with rhBMP-2 for an Implant Surgical Guide Stent and Bone Graft Material: A Pilot Animal Study

    OpenAIRE

    Bae, Ji Cheol; Lee, Jin-Ju; Shim, Jin-Hyung; Park, Keun-Ho; Lee, Jeong-Seok; Bae, Eun-Bin; Choi, Jae-Won; Huh, Jung-Bo

    2017-01-01

    In this study, a new concept of a 3D-printed scaffold was introduced for the accurate placement of an implant and the application of a recombinant human bone morphogenetic protein-2 (rhBMP-2)-loaded bone graft. This preliminary study was conducted using two adult beagles to evaluate the 3D-printed polycaprolactone (PCL)/β-tricalcium phosphate (β-TCP)/bone decellularized extracellular matrix (bdECM) scaffold conjugated with rhBMP-2 for the simultaneous use as an implant surgical guide stent an...

  10. Experimental study on bone tissue reaction around HA implants radiated after implantation

    International Nuclear Information System (INIS)

    Kudo, Masato; Matsui, Yoshiro; Tamura, Sayaka; Chen, Xuan; Uchida, Haruo; Mori, Kimie; Ohno, Kohsuke; Michi, Ken-ichi

    1998-01-01

    This study was conducted to investigate histologically and histomorphometrically the tissue reaction around hydroxylapatite (HA) implants that underwent irradiation in 3 different periods in the course of bone healing after implantation. The cylindrical high-density HA implants were implanted in 48 Japanese white rabbit mandibles. A single 15 Gy dose was applied to the mandible 5, 14, or 28 days after implantation. The rabbits were sacrificed 7, 14, 28, and 90 days after irradiation. Nonirradiated rabbits were used as controls. CMR, labeling with tetracycline and calcein, and non-decalcified specimens stained with toluidine blue were used for histological analyses and histomorphometric measurements. The results were as follows: In the rabbits irradiated 5 days after implantation, the HA-bone contact was observed later than that in the controls and the bone-implant contact surface ratio was lower than that in the controls at examination because necrosis of the newly-formed bone occurred just after irradiation. HA-bone contact of the rabbits irradiated 14 and 28 days after implantation was similar to that of the controls. And, bone remodeling was suppressed in rabbits of each group sacrificed at 90 days after irradiation. The results suggested that a short interval between implantation and irradiation causes direct contact between HA implant and bone and a long lapse of time before irradiation hardly affects the bone-implant contact, but delays bone remodeling. Therefore, it is necessary to prevent overloading the HA implants irradiated after implantation and pay utmost attention to conditions around the bone-implant contact. (author)

  11. Surgical insertion of transmitters and telemetry methods in fisheries research

    DEFF Research Database (Denmark)

    Rub, A. Michelle Wargo; Jepsen, Niels; Liedtke, Theresa L.

    2014-01-01

    ) will be described. Effects of surgical insertion of transmitters (ie, tagging) and aspects of the surgical implantation process where collaboration and professional exchanges among nonveterinarian researchers and veterinarians may be most fruitful will be discussed. Although this report focuses on surgical...

  12. Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

    Directory of Open Access Journals (Sweden)

    Sung-Eun Kim

    2014-09-01

    Full Text Available BackgroundIn 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience.MethodsFrom November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction.ResultsThe mean breast resection volume was 240 mL (range, 83-540 mL. The mean size of the breast implants was 217 mL (range, 125-395 mL. Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen.ConclusionsBy using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

  13. Breast Reconstruction with Implants

    Science.gov (United States)

    ... your surgical options and discuss the advantages and disadvantages of implant-based reconstruction, and may show you ... Policy Notice of Privacy Practices Notice of Nondiscrimination Advertising Mayo Clinic is a not-for-profit organization ...

  14. Monte Carlo simulation of boron-ion implantation into single-crystal silicon

    International Nuclear Information System (INIS)

    Klein, K.M.

    1991-01-01

    A physically based Monte Carlo boron implantation model developed comprehends previously neglected but important implant parameters such as native oxide layers, wafer temperature, beam divergence, tilt angle, rotation (twist) angle, and dose, in addition to energy. This model uses as its foundation the MARLOWE Monte Carlo simulation code developed at Oak Ridge National Laboratory for the analysis of radiation effects in materials. This code was carefully adapted for the simulation of ion implantation, and a number of significant improvements have been made, including the addition of atomic pair specific interatomic potentials, the implementation of a newly developed local electron concentration dependent electronic stopping model, and the implementation of a newly developed cumulative damage model. This improved version of the code, known as UT-MARLOWE, allows boron implantation profiles to be accurately predicted as a function of energy, tilt angle, rotation angle, and dose. This code has also been used in the development and implementation of an accurate and efficient two-dimensional boron implantation model

  15. The key to success: maintaining the long-term health of implants.

    Science.gov (United States)

    Silverstein, L; Garg, A; Callan, D; Shatz, P

    1998-02-01

    During the infancy years of dental implantology, the emphasis for long-term success of osseointegrated implants was the surgical phase of dental implantology. In the years that followed, the emphasis for success had switched from a purely surgical influence to focusing more on the proper fixture placement which would be dictated by the prosthetic and aesthetic needs of each particular case. In more recent years, the dental profession has recognized professional implant maintenance and diligent patient home care as two critical factors for the long-term success of dental implants. The microbiota and clinical presentation of peri-implantitis is the same as periodontitis around a natural tooth.

  16. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma.

    Science.gov (United States)

    Wang, Rui; Bi, Chun-Chao; Lei, Chun-Ling; Sun, Wen-Tao; Wang, Shan-Shan; Dong, Xiao-Juan

    2014-01-01

    To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL) implantation. Non-comparative retrospective observational case series. 30 cases (30 eyes) of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Ophthalmology of Xi'an No.4 Hospital from 2007 to 2011. According to the different situations of lens subluxation/dislocation, various surgical procedures were performed such as crystalline lens phacoemulsification, crystalline lens phacoemulsification combined anterior vitrectomy, intracapsular cataract extraction combined anterior vitrectomy, lensectomy combined anterior vitrectomy though peripheral transparent cornea incision, pars plana lensectomy combined pars plana vitrectomy, and intravitreal cavity crystalline lens phacofragmentation combined pars plana vitrectomy. And whether to implement trabeculectomy depended on the different situations of secondary glaucoma. The posterior chamber intraocular lenses (PC-IOLs) were implanted in the capsular-bag or trassclerally sutured in the sulus decided by whether the capsular were present. visual acuity, intraocular pressure, the situation of intraocular lens and complications after the operations. The follow-up time was 11-36mo (21.4±7.13). Postoperative visual acuity of all eyes were improved; 28 cases maintained IOP below 21 mm Hg; 2 cases had slightly IOL subluxation, 4 cases had slightly tilted lens optical area; 1 case had postoperative choroidal detachment; 4 cases had postoperative corneal edema more than 1wk, but eventually recovered transparent; 2 cases had mild postoperative vitreous hemorrhage, and absorbed 4wk later. There was no postoperative retinal detachment, IOL dislocation, and endophthalmitis. To take early treatment of traumatic lens

  17. Are short implants in the mandible safe?

    Directory of Open Access Journals (Sweden)

    Sergio Henrique Gonçalves Motta

    2009-10-01

    Full Text Available Objective: To analyze the importance of bioengineering and the improvement in surgical techniques demonstrated by the rates attained of the prevalence of successful placement of dental implants in the posterior region of the mandible, in D3 bone quality in patients between the ages of 52 and 60 years, with dentures fixed on 8.5 mm implants. Methods: The statistical data for this retrospective study were collected at the Post-Graduation Center of the Integrated Dentistry Center, Faculty of Sarandi / Academy of Dentistry - Rio de Janeiro, at the CLIVO clinic, from among a total of 2.294 implants placed in the mandible, in the period from 1999 to 2007. There was a total of 1.056 short implants, of a length shorter than or equal to 10 mm, among which 20 implants were randomly chosen and analyzed. Results: The data were treated statistically and comparison of these data was consubstantiated in constructive data analysis by means of Statistical Pattern Recognition Methods for each variable under study. A success rate of 85% was obtained, and the need to take certain care when indicating the use of short implants was verified. Conclusion: Bioengineering and the development of present day surgical techniques have optimized the use of short implants, with the aim of avoiding advanced surgeries. To compensate the smaller size, there are some factors that must be observed, such as: Bone quality, crown/implant ratio, number and diameter of implants, macroscopic and microscopic geometry of the implants, magnitude of mesial occlusal forces.

  18. A standard operating procedure for the surgical implantation of transmitters in juvenile salmonids

    Science.gov (United States)

    Liedtke, T.L.; Beeman, J.W.; Gee, L.P.

    2012-01-01

    Biotelemetry is a useful tool to monitor the movements of animals and is widely applied in fisheries research. Radio or acoustic technology can be used, depending on the study design and the environmental conditions in the study area. A broad definition of telemetry also includes the use of Passive Integrated Transponder (PIT) tags, either separately or with a radio or acoustic transmitter. To use telemetry, fish must be equipped with a transmitter. Although there are several attachment procedures available, surgical implantation of transmitters in the abdominal cavity is recognized as the best technique for long-term telemetry studies in general (Stasko and Pincock, 1977; Winter, 1996; Jepsen, 2003), and specifically for juvenile salmonids, Oncorhynchus spp. (Adams and others, 1998a, 1998b; Martinelli and others, 1998; Hall and others, 2009). Studies that use telemetry assume that the processes by which the animals are captured, handled, and tagged, as well as the act of carrying the transmitter, will have minimal effect on their behavior and performance. This assumption, commonly stated as a lack of transmitter effects, must be valid if telemetry studies are to describe accurately the movements and behavior of an entire population of interest, rather than the subset of that population that carries transmitters. This document describes a standard operating procedure (SOP) for surgical implantation of radio or acoustic transmitters in juvenile salmonids. The procedures were developed from a broad base of published information, laboratory experiments, and practical experience in tagging thousands of fish for numerous studies of juvenile salmon movements near Columbia River and Snake River hydroelectric dams. Staff from the Western Fisheries Research Center's Columbia River Research Laboratory (CRRL) frequently have used telemetry studies to evaluate new structures or operations at hydroelectric dams in the Columbia River Basin, and these evaluations typically

  19. Location of unaccessible implant surface areas during debridement in simulated peri-implantitis therapy.

    Science.gov (United States)

    Steiger-Ronay, Valerie; Merlini, Andrea; Wiedemeier, Daniel B; Schmidlin, Patrick R; Attin, Thomas; Sahrmann, Philipp

    2017-11-28

    An in vitro model for peri-implantitis treatment was used to identify areas that are clinically difficult to clean by analyzing the pattern of residual stain after debridement with commonly employed instruments. Original data from two previous publications, which simulated surgical (SA) and non-surgical (NSA) implant debridement on two different implant systems respectively, were reanalyzed regarding the localization pattern of residual stains after instrumentation. Two blinded examiners evaluated standardized photographs of 360 initially ink-stained dental implants, which were cleaned at variable defect angulations (30, 60, or 90°), using different instrument types (Gracey curette, ultrasonic scaler or air powder abrasive device) and treatment approaches (SA or NSA). Predefined implant surface areas were graded for residual stain using scores ranging from one (stain-covered) to six (clean). Score differences between respective implant areas were tested for significance by pairwise comparisons using Wilcoxon-rank-sum-tests with a significance level α = 5%. Best scores were found at the machined surface areas (SA: 5.58 ± 0.43, NSA: 4.76 ± 1.09), followed by the tips of the threads (SA: 4.29 ± 0.44, NSA: 4.43 ± 0.61), and areas between threads (SA: 3.79 ± 0.89, NSA: 2.42 ± 1.11). Apically facing threads were most difficult to clean (SA: 1.70 ± 0.92, NSA: 2.42 ± 1.11). Here, air powder abrasives provided the best results. Machined surfaces at the implant shoulder were well accessible and showed least amounts of residual stain. Apically facing thread surfaces constituted the area with most residual stain regardless of treatment approach.

  20. A new surgical method for penile girth enhancement.

    Science.gov (United States)

    Li, Xiaoge; Tao, Ling; Cao, Chuan; Shi, Haishan; Li, Le; Chen, Liang; Li, Shirong

    2015-01-01

    We developed a new surgical model of penile girth enhancement in dog, with minimal damage, fewer complications, and high success rate, to enable the experimental investigation of penile implants. We obtained materials for penile girth enhancement by processing the pericardium and blood vessel wall collected from pigs. Incisions were made at the penile bulb for the implantation of the materials, and facilitate observation and data collection, based on the anatomical features of dog's penis. We measured the girth of the flaccid penis before and after the operation, and erectile function at 1-month postoperation. In addition to evaluation of recovery from the incision and local pathological changes, ultrasonic examination was performed to monitor the long-term changes associated with implantation. The mean girth of the flaccid penis significantly increased from 7.37±0.40 cm before the operation, to 8.70±0.56 cm postoperation. Dogs resumed normal mating at 1 month after the operation, without any significant change in the mating time. Ultrasonic examination clearly illustrated the implants, and helped in the measurement of the distance between the materials and the baculum. Chinese Rural dog is a promising animal model for penile girth enhancement surgery. The findings demonstrated that surgical implantation into penile bulb was associated with less damage, faster postoperative recovery, and higher success. For the first time, ultrasonic examination provided objective data on the surgical outcomes of penile girth enhancement.

  1. Effects of dose reduction on multi-detector computed tomographic images in evaluating the maxilla and mandible for pre-surgical implant planning: a cadaveric study.

    Science.gov (United States)

    Koizumi, Hiroshi; Sur, Jaideep; Seki, Kenji; Nakajima, Koh; Sano, Tsukasa; Okano, Tomohiro

    2010-08-01

    To assess effects of dose reduction on image quality in evaluating maxilla and mandible for pre-surgical implant planning using cadavers. Six cadavers were used for the study using multi-detector computed tomography (CT) operated at 120 kV and the variable tube current of 80, 40, 20 and 10 mA. A slice thickness of 0.625 mm and pitch 1 were used. Multi-planar images perpendicular and parallel to dentitions were created. The images were evaluated by five oral radiologists in terms of visibility of the anatomical landmarks including alveolar crest, mandibular canal, floors of the maxillary sinus and nasal cavity, contours/cortical layer of jaw bones and the details of trabecular bone. Observers were asked to determine the quality of the images in comparison with 80 mA images based on the criteria: excellent, good, fair or non-diagnostic. The average scores of all observers were calculated for each specimen in all exposure conditions. The 40 mA images could visualize such landmarks and were evaluated to be same or almost equivalent in quality to the 80 mA images. Even the 20 mA images could be accepted just for diagnostic purpose for implant with substantial deterioration of the image quality. The 10 mA images may not be accepted because of the obscured contour caused by image noise. Significant dose reduction by lowering mA can be utilized for pre-surgical implant planning in multi-detector CT.

  2. Cranial reconstruction: 3D biomodel and custom-built implant created using additive manufacturing.

    Science.gov (United States)

    Jardini, André Luiz; Larosa, Maria Aparecida; Maciel Filho, Rubens; Zavaglia, Cecília Amélia de Carvalho; Bernardes, Luis Fernando; Lambert, Carlos Salles; Calderoni, Davi Reis; Kharmandayan, Paulo

    2014-12-01

    Additive manufacturing (AM) technology from engineering has helped to achieve several advances in the medical field, particularly as far as fabrication of implants is concerned. The use of AM has made it possible to carry out surgical planning and simulation using a three-dimensional physical model which accurately represents the patient's anatomy. AM technology enables the production of models and implants directly from a 3D virtual model, facilitating surgical procedures and reducing risks. Furthermore, AM has been used to produce implants designed for individual patients in areas of medicine such as craniomaxillofacial surgery, with optimal size, shape and mechanical properties. This work presents AM technologies which were applied to design and fabricate a biomodel and customized implant for the surgical reconstruction of a large cranial defect. A series of computed tomography data was obtained and software was used to extract the cranial geometry. The protocol presented was used to create an anatomic biomodel of the bone defect for surgical planning and, finally, the design and manufacture of the patient-specific implant. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  3. Analysis of percussion response of dental implants: An in vitro study

    International Nuclear Information System (INIS)

    Dinh, Andrew; Sheets, Cherilyn G.; Earthman, James C.

    2013-01-01

    The Periometer® quantitative percussion system was used to interrogate the interfacial stability of implants in vitro for comparison with X-ray computer tomography (CT) data. Selected implants were placed as per standard practice in bone stimulant polyurethane blocks. The dimensions of the surgical sites surrounding the implants were analyzed using X-ray computer tomography (CT) to determine the quality of support at the implant–bone interface. In particular, the misfit between the size of the surgical site and the corresponding implant was determined for each sample. The resulting average surgical site error from the CT scans was found to exhibit good agreement with the presence of irregularities found in the percussion data. - Highlights: ► Percussion response versus time exhibited irregularities for some in vitro samples. ► X-Ray CT was used to assess the interface integrity for six implant–bone specimens. ► Irregularities in percussion data correlate well with the CT based assessments

  4. Physical Properties of Silicone Gel Breast Implants.

    Science.gov (United States)

    Jewell, Mark L; Bengtson, Bradley P; Smither, Kate; Nuti, Gina; Perry, TracyAnn

    2018-04-28

    Surgical applications using breast implants are individualized operations to fill and shape the breast. Physical properties beyond shape, size, and surface texture are important considerations during implant selection. Compare form stability, gel material properties, and shell thickness of textured shaped, textured round, and smooth round breast implants from 4 manufacturers: Allergan, Mentor, Sientra, and Establishment Labs through bench testing. Using a mandrel height gauge, form stability was measured by retention of dimensions on device movement from a horizontal to vertical supported orientation. Dynamic response of gel material (gel cohesivity, resistance to gel deformation, energy absorption) was measured using a synchronized target laser following application of graded negative pressure. Shell thickness was measured using digital thickness gauge calipers. Form stability, gel material properties, and shell thickness differed across breast implants. Of textured shaped devices, Allergan Natrelle 410 exhibited greater form stability than Mentor MemoryShape and Sientra Shaped implants. Allergan Inspira round implants containing TruForm 3 gel had greater form stability, higher gel cohesivity, greater resistance to gel deformation, and lower energy absorption than those containing TruForm 2 gel and in turn, implants containing TruForm 1 gel. Shell thickness was greater for textured versus smooth devices, and differed across styles. Gel cohesivity, resistance to gel deformation, and energy absorption are directly related to form stability, which in turn determines shape retention. These characteristics provide information to aid surgeons choosing an implant based on surgical application, patient tissue characteristics, and desired outcome.

  5. Sirviendo a los estudiantes sordos que tienen Los implantes cocleares. Hoja de consejos de PEPNet (Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet)

    Science.gov (United States)

    Clark, Catherine

    2010-01-01

    This version of "Serving Deaf Students Who Have Cochlear Implants. PEPNet Tipsheet," written in Spanish, describes how cochlear implants (CIs) work. CIs are complex electronic devices surgically implanted under the skin behind the ear. These devices utilize electrodes placed in the inner ear (the cochlea) to stimulate the auditory nerve of…

  6. Training needs for general dentistry residents to place and restore two-implant-retained mandibular overdentures.

    Science.gov (United States)

    Malmstrom, Hans; Xiao, Jin; Romanos, Georgios E; Ren, Yan-Fang

    2015-01-01

    Implant therapy is rapidly becoming a standard of care for replacing missing dentition. Predoctoral dental curricula include some training in the implant restorative phase but offer limited exposure to the surgical phase, so it is important for postdoctoral general dentistry residency programs to provide competency training in all phases of implant therapy. The aim of this study was to determine the training needed for general dentistry residents to achieve competence in this area, specifically by defining the number of clinical experiences necessary in both the surgical and prosthetic phases of implant-retained mandibular overdenture construction (IRMOD). Fifteen Advanced Education in General Dentistry (AEGD) residents at one academic dental institution placed two implants in a total of 50 patients with edentulous mandibles and subsequently restored them with IRMOD. The supervising faculty member and the residents evaluated the competency level on a five-point scale after each implant placement and prosthetic case completion. According to the faculty evaluations, the residents achieved surgical competence after placing two implants in four to six cases and prosthetic management competence after restoring two to four cases of IRMOD. All 50 patients were satisfied with the treatment outcomes of IRMOD. This study concluded that general dentistry residents could potentially achieve competence in both the surgical and prosthetic phases of implant therapy while enrolled in an AEGD program.

  7. Venous Obstruction Following Pacemaker or Implantable Cardioverter-Defibrillator Implantation, Mini Review

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Akbarzadeh

    2016-08-01

    Full Text Available Venous obstruction is relatively frequent following permanent pacemaker or implantable cardioverter-defibrillator (ICD implantation. However, most of them are asymptomatic. Although the exact risk factor for this complication is not known, number of leads, heart failure and infection may prone the patient to this complication. The goal standard for detection of vein stenosis is venography; however, ultrasound sonography has an acceptable accuracy. Anticoagulant therapy may be considered for symptomatic patients. For device upgrading, non-functional leads removal, venoplasty and rarely surgical treatment may be indicated.

  8. Bone-anchored titanium implants for auricular rehabilitation: case report and review of literature.

    Science.gov (United States)

    Gumieiro, Emne Hammoud; Dib, Luciano Lauria; Jahn, Ricardo Schmitutz; Santos Junior, João Ferreira dos; Nannmark, Ulf; Granström, Gösta; Abrahão, Márcio

    2009-01-01

    Osseointegrated implants have acquired an important role in the prosthetic rehabilitation of patients with craniofacial defects. The main indications are lack of local tissue for autogenous reconstruction, previous reconstruction failure and selection of this technique by the patient. This paper presents a clinical case and discusses indications and advantages of the osseointegrated implant technique for retention of auricular prostheses. Case report, Universidade Federal de São Paulo (UNIFESP). A female patient received three auricular implants after surgical resection of a hemangioma in her left ear. The time taken for osseointegration of the temporal bone was three months. After fabrication of the implant-retained auricular prosthesis, the patient was monitored for 12 months. The clinical parameters evaluated showed good postoperative healing, healthy peri-implant tissue, good hygiene and no loss of implants. Good hygiene combined with thin and immobile peri-implant soft tissues resulted in minimal complications. Craniofacial implant integration appears to be site-dependent; increasing age affects osseointegration in the temporal bone. The frequency of adverse skin reactions in peri-implant tissues is generally low. The surgical technique for rehabilitation using implant-retained auricular prostheses seems to be simple. It is associated with low rates of adverse skin reactions and long-term complications. Prostheses anchored by osseointegrated implants seem to provide better retention than do prostheses supported on spectacle frames, less risk of discoloration through the use of adhesives and better esthetic results than do prostheses anchored in the surgical cavity.

  9. Atypical Case of Three Dental Implants Displaced into the Maxillary Sinus

    Directory of Open Access Journals (Sweden)

    João Felipe Bonatto Bruniera

    2015-01-01

    Full Text Available Oral rehabilitation with dental implants has become a routine treatment in contemporary dentistry. The displacement of dental implants into the sinus membrane, a complication related to the maxillary sinus, is one of the most common accidents reported in the literature. The treatment for this complication is the surgical removal of the implant. A 60-year-old woman with three dental implants displaced into the maxillary sinus (one implant displaced into the left maxillary sinus and two implants displaced into the right maxillary sinus underwent surgery for removal of the implants. The surgery to remove the implants was performed under local anesthesia through the Caldwell-Luc technique. The patient was subsequently administered antibiotic, anti-inflammatory, and analgesic drugs. The patient returned 7 days after the surgery for suture removal and is being regularly monitored to determine whether future rehabilitation of the edentulous area is necessary. In conclusion, surgical removal of the dental implant displaced into the maxillary sinus is the treatment of choice. This technique is appropriate because it allows the use of local anesthesia and provides direct visualization for the removal of the implants.

  10. New Criteria of Indication and Selection of Patients to Cochlear Implant

    Directory of Open Access Journals (Sweden)

    André L. L. Sampaio

    2011-01-01

    Full Text Available Numerous changes continue to occur in cochlear implant candidacy. In general, these have been accompanied by concomitant and satisfactory changes in surgical techniques. Together, this has advanced the utility and safety of cochlear implantation. Most devices are now approved for use in patients with severe to profound unilateral hearing loss rather then the prior requirement of a bilateral profound loss. Furthermore, studies have begun utilizing short electrode arrays for shallow insertion in patients with considerable low-frequency residual hearing. This technique will allow the recipient to continue to use acoustically amplified hearing for the low frequencies simultaneously with a cochlear implant for the high frequencies. The advances in design of, and indications for, cochlear implants have been matched by improvements in surgical techniques and decrease in complications. The resulting improvements in safety and efficacy have further encouraged the use of these devices. This paper will review the new concepts in the candidacy of cochlear implant. Medline data base was used to search articles dealing with the following topics: cochlear implant in younger children, cochlear implant and hearing preservation, cochlear implant for unilateral deafness and tinnitus, genetic hearing loss and cochlear implant, bilateral cochlear implant, neuropathy and cochlear implant and neural plasticity, and the selection of patients for cochlear implant.

  11. Characterization of the bone-metal implant interface by Digital Volume Correlation of in-situ loading using neutron tomography.

    Science.gov (United States)

    Le Cann, Sophie; Tudisco, Erika; Perdikouri, Christina; Belfrage, Ola; Kaestner, Anders; Hall, Stephen; Tägil, Magnus; Isaksson, Hanna

    2017-11-01

    Metallic implants are commonly used as surgical treatments for many orthopedic conditions. The long-term stability of implants relies on an adequate integration with the surrounding bone. Unsuccessful integration could lead to implant loosening. By combining mechanical loading with high-resolution 3D imaging methods, followed by image analysis such as Digital Volume Correlation (DVC), we aim at evaluating ex vivo the mechanical resistance of newly formed bone at the interface. X-rays tomography is commonly used to image bone but induces artefacts close to metallic components. Utilizing a different interaction with matter, neutron tomography is a promising alternative but has not yet been used in studies of bone mechanics. This work demonstrates that neutron tomography during in situ loading is a feasible tool to characterize the mechanical response of bone-implant interfaces, especially when combined with DVC. Experiments were performed where metal screws were implanted in rat tibiae during 4 weeks. The screws were pulled-out while the samples were sequentially imaged in situ with neutron tomography. The images were analyzed to quantify bone ingrowth around the implants. DVC was used to track the internal displacements and calculate the strain fields in the bone during loading. The neutron images were free of metal-related artefacts, which enabled accurate quantification of bone ingrowth on the screw (ranging from 60% to 71%). DVC allowed successful identification of the deformation and cracks that occurred during mechanical loading and led to final failure of the bone-implant interface. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Combination therapy of surgical tumor resection with implantation of a hydrogel containing camptothecin-loaded poly(lactic-co-glycolic acid) microspheres in a C6 rat glioma model.

    Science.gov (United States)

    Ozeki, Tetsuya; Kaneko, Daiki; Hashizawa, Kosuke; Imai, Yoshihiro; Tagami, Tatsuaki; Okada, Hiroaki

    2012-01-01

    We have developed a drug-loaded poly(lactic-co-glycolic acid) (PLGA) microsphere-containing thermoreversible gelation polymer (TGP) (drug/PLGA/TGP) formulation as a novel device for implantation after surgical glioma resection. TGP is a thermosensitive polymer that is a gel at body temperature and a sol at room temperature. When a drug/PLGA/TGP formulation is injected into a target site, PLGA microspheres in TGP gel localize at the injection site and do not diffuse across the entire brain tissue, and thus, sustained drug release from the PLGA microspheres at the target site is expected. Using in vivo imaging, we confirmed that the implantation of indocyanine green (ICG)/PLGA/TGP formulation exhibited a stronger localization of ICG at the injection site 28 d after injection compared with that of ICG/PLGA formulation. The therapeutic effect (mean survival) was evaluated in a C6 rat glioma model. Surgical tumor resection alone showed almost no effect on survival (controls, 18 d; surgical resection; 18.5 d). Survival was prolonged after the treatment with a camptothecin (CPT; 10 µg)/PLGA/TGP formulation (24 d). The combination treatment of surgical tumor resection and CPT/PLGA/TGP showed almost the same therapeutic effect (24 d) compared with CPT/PLGA/TGP alone, while the combination treatment produced long term survivors (>60 d). Therefore, the CPT/PLGA/TGP formulation can be an effective candidate for localized and sustained long-term glioma therapy.

  13. Facial and occlusal esthetic improvements of an adult skeletal Class III malocclusion using surgical, orthodontic, and implant treatment

    Science.gov (United States)

    de Almeida Cardoso, Mauricio; de Avila, Erica Dorigatti; Guedes, Fabio Pinto; Battilani Filho, Valter Antonio Ban; Capelozza Filho, Leopoldino; Correa, Marcio Aurelio; Nary Filho, Hugo

    2016-01-01

    The aim of this clinical report is to describe the complex treatment of an adult Class III malocclusion patient who was disappointed with the outcome of a previous oral rehabilitation. Interdisciplinary treatment planning was performed with a primary indication for implant removal because of marginal bone loss and gingival recession, followed by orthodontic and surgical procedures to correct the esthetics and skeletal malocclusion. The comprehensive treatment approach included: (1) implant removal in the area of the central incisors; (2) combined orthodontic decompensation with mesial displacement and forced extrusion of the lateral incisors; (3) extraction of the lateral incisors and placement of new implants corresponding to the central incisors, which received provisional crowns; (4) orthognathic surgery for maxillary advancement to improve occlusal and facial relationships; and finally, (5) orthodontic refinement followed by definitive prosthetic rehabilitation of the maxillary central incisors and reshaping of the adjacent teeth. At the three-year follow-up, clinical and radiographic examinations showed successful replacement of the central incisors and improved skeletal and esthetic appearances. Moreover, a Class II molar relationship was obtained with an ideal overbite, overjet, and intercuspation. In conclusion, we report the successful esthetic anterior rehabilitation of a complex case in which interdisciplinary treatment planning improved facial harmony, provided gingival architecture with sufficient width and thickness, and improved smile esthetics, resulting in enhanced patient comfort and satisfaction. This clinical case report might be useful to improve facial esthetics and occlusion in patients with dentoalveolar and skeletal defects. PMID:26877982

  14. An introduction to the practical and ethical perspectives on the need to advance and standardize the intracoelomic surgical implantation of electronic tags in fish

    Science.gov (United States)

    Brown, R.S.; Eppard, M.B.; Murchie, K.J.; Nielsen, J.L.; Cooke, S.J.

    2011-01-01

    The intracoelomic surgical implantation of electronic tags (including radio and acoustic telemetry transmitters, passive integrated transponders and archival biologgers) is frequently used for conducting studies on fish. Electronic tagging studies provide information on the spatial ecology, behavior and survival of fish in marine and freshwater systems. However, any surgical procedure, particularly one where a laparotomy is performed and the coelomic cavity is opened, has the potential to alter the survival, behavior or condition of the animal which can impair welfare and introduce bias. Given that management, regulatory and conservation decisions are based on the assumption that fish implanted with electronic tags have similar fates and behavior relative to untagged conspecifics, it is critical to ensure that best surgical practices are being used. Also, the current lack of standardized surgical procedures and reporting of specific methodological details precludes cross-study and cross-year analyses which would further progress the field of fisheries science. This compilation of papers seeks to identify the best practices for the entire intracoelomic tagging procedure including pre- and post-operative care, anesthesia, wound closure, and use of antibiotics. Although there is a particular focus on salmonid smolts given the large body of literature available on that group, other life-stages and species of fish are discussed where there is sufficient knowledge. Additional papers explore the role of the veterinarian in fish surgeries, the need for minimal standards in the training of fish surgeons, providing a call for more complete and transparent procedures, and identifying trends in procedures and research needs. Collectively, this body of knowledge should help to improve data quality (including comparability and repeatability), enhance management and conservation strategies, and maintain the welfare status of tagged fish. ?? 2010 Springer Science+Business Media B.V.

  15. Reconstruction of a Severely Atrophied Alveolar Ridge by Computer-Aided Gingival Simulation and 3D-Printed Surgical Guide: A Case Report.

    Science.gov (United States)

    Song, In-Seok; Lee, Mi-Ran; Ryu, Jae-Jun; Lee, Ui-Lyong

    Dental implants positioned in severely atrophied anterior maxillae require esthetic or functional compromises. This case report describes the rehabilitation of a severely atrophied alveolar ridge with a three-dimensional (3D) computer-aided design/computer-aided manufacture (CAD/CAM) surgical guide. A 50-year-old woman had a severely atrophied anterior maxilla with unfavorably positioned dental implants. Functional and esthetic prosthodontic restoration was difficult to achieve. An anterior segmental osteotomy was planned to reposition the dental implants. A 3D surgical guide was designed for precise relocation of the segment. The surgical guide firmly grasped the impression copings of the dental implants, minimizing surgical errors. Three-dimensional gingival simulation was used preoperatively to estimate the appropriate position of the gingiva. Rigid fixation to the surrounding bone allowed immobilization of the implant-bone segment. Satisfactory esthetic and functional outcomes were attained 6 months after surgery. Finally, a severely atrophied alveolar ridge with unfavorably positioned dental implants was recovered with minimal esthetic and functional deterioration using gingival simulation and a 3D CAD/CAM surgical guide.

  16. Bone-anchored titanium implants for auricular rehabilitation: case report and review of literature

    Directory of Open Access Journals (Sweden)

    Emne Hammoud Gumieiro

    Full Text Available CONTEXT AND OBJECTIVE: Osseointegrated implants have acquired an important role in the prosthetic rehabilitation of patients with craniofacial defects. The main indications are lack of local tissue for autogenous reconstruction, previous reconstruction failure and selection of this technique by the patient. This paper presents a clinical case and discusses indications and advantages of the osseointegrated implant technique for retention of auricular prostheses. TYPE OF STUDY: Case report, Universidade Federal de São Paulo (UNIFESP. METHODS: A female patient received three auricular implants after surgical resection of a hemangioma in her left ear. The time taken for osseointegration of the temporal bone was three months. After fabrication of the implant-retained auricular prosthesis, the patient was monitored for 12 months. RESULTS: The clinical parameters evaluated showed good postoperative healing, healthy peri-implant tissue, good hygiene and no loss of implants. Good hygiene combined with thin and immobile peri-implant soft tissues resulted in minimal complications. Craniofacial implant integration appears to be site-dependent; increasing age affects osseointegration in the temporal bone. The frequency of adverse skin reactions in peri-implant tissues is generally low. CONCLUSION: The surgical technique for rehabilitation using implant-retained auricular prostheses seems to be simple. It is associated with low rates of adverse skin reactions and long-term complications. Prostheses anchored by osseointegrated implants seem to provide better retention than do prostheses supported on spectacle frames, less risk of discoloration through the use of adhesives and better esthetic results than do prostheses anchored in the surgical cavity

  17. Efficiency of photodynamic therapy in the treatment of peri-implantitis: A three-month randomized controlled clinical trial

    Directory of Open Access Journals (Sweden)

    Rakašević Dragana

    2016-01-01

    Full Text Available Introduction. Peri-implantitis is an inflammatory lesion of peri-implant tissues. Eradication of the causative bacteria and decontamination of the implant surface is essential in achieving predictable and stabile clinical results. Photodynamic therapy (PDT is non-invasive adjuvant therapeutic method to surgery in the treatment of bacterial infection. Objective. The aim of this study was to evaluate early clinical and microbiological outcomes of periimplantitis after surgical therapy with adjuvant PDT. Methods. Fifty-two diagnosed peri-implantitis sites were divided into two groups. PDT was used for decontamination of implant surface in the study group; in the control group, chlorhexidine gel (CHX followed by saline irrigation was applied. Several clinical parameters were recorded before the treatment (baseline values and three months after surgical treatment. Samples for microbiological identification were collected before therapy, during the surgical therapy (before and after decontamination of implant surface, and three months thereafter, and analyzed with identification systems using biochemical analysis. Results. The use of PDT resulted in significant decrease of bleeding on probing in comparison to CHX (p < 0.001. It showed significant decontamination of implant surfaces with complete elimination of anaerobic bacteria immediately after surgical procedure and three months later. Conclusion. The results indicate that PDT can be used as an adjuvant therapy to surgery for decontamination of implant surface and surrounding peri-implant tissues within the treatment of peri-implantitis. [Projekat Ministarstva nauke Republike Srbije, br. 41008

  18. Newly graduated nurses' use of knowledge sources in clinical decision-making

    DEFF Research Database (Denmark)

    Voldbjerg, Siri Lygum; Grønkjaer, Mette; Wiechula, Rick

    2017-01-01

    AIMS AND OBJECTIVES: To explore which knowledge sources newly graduated nurses' use in clinical decision-making and why and how they are used. BACKGROUND: In spite of an increased educational focus on skills and competencies within evidence based practice newly graduated nurses' ability to use...... approaches to strengthen the knowledgebase used in clinical decision-making. DESIGN AND METHODS: Ethnographic study using participant-observation and individual semi-structured interviews of nine Danish newly graduated nurses in medical and surgical hospital settings. RESULTS: Newly graduates use...... in clinical decision-making. If newly graduates are to be supported in an articulate and reflective use of a variety of sources, they have to be allocated to experienced nurses who model a reflective, articulate and balanced use of knowledge sources. This article is protected by copyright. All rights reserved....

  19. Implant surface preparation in the surgical treatment of experimental peri-implantitis with autogenous bone graft and ePTFE membrane in cynomolgus monkeys

    DEFF Research Database (Denmark)

    Schou, Søren; Holmstrup, Palle; Jørgensen, Torben

    2003-01-01

    peri-implantitis; treatment; implant surface preparation; nonhuman primates; histology; stereology......peri-implantitis; treatment; implant surface preparation; nonhuman primates; histology; stereology...

  20. Range of impingement-free abduction and adduction deficit after reverse shoulder arthroplasty. Hierarchy of surgical and implant-design-related factors.

    Science.gov (United States)

    Gutiérrez, Sergio; Comiskey, Charles A; Luo, Zong-Ping; Pupello, Derek R; Frankle, Mark A

    2008-12-01

    Evaluations of functional outcomes of reverse shoulder arthroplasty have revealed variable improvements in the range of motion and high rates of scapular notching. The purpose of this study was to systematically examine the impact of surgical factors (location of the glenosphere on the glenoid and tilt angle of the glenosphere on the glenoid) and implant-related factors (implant size, center-of-rotation offset, and humeral neck-shaft angle) on impingement-free abduction motion. A computer model was developed to virtually simulate abduction/adduction motion and its dependence on five surgical and implant-related factors. Three conditions were tested for each factor, resulting in a total of 243 simulated combinations. The overall motion was determined from 0 degrees of abduction until maximum abduction, which would be limited by impingement of the humerosocket on the scapula. In those combinations in which 0 degrees of abduction could not be achieved, the adduction deficit was recorded. The largest average increase in the range of impingement-free abduction motion resulted from a more lateral center-of-rotation offset: the average increase was 31.9 degrees with a change in the center-of-rotation offset from 0 to 10 mm, and this change resulted in an increase in abduction motion in eighty of the eighty-one combinations. The position of the glenosphere on the glenoid was associated with the second largest average increase in abduction motion (28.1 degrees when the glenosphere position was changed from superior to inferior, with the change resulting in an increase in seventy-one of the eighty-one combinations). These factors were followed by glenosphere tilt, humeral neck-shaft angle, and prosthetic size in terms of their effects on abduction motion. The largest effect in terms of avoiding an adduction deficit was provided by a humeral neck-shaft angle of 130 degrees (the deficit was avoided in forty-nine of the eighty-one combinations in which this angle was used

  1. REHABILITATION OF SEVERELY ATROPHIED UPPER JAW WITH INTRAOSSAL DENTAL IMPLANTS - clinical case

    Directory of Open Access Journals (Sweden)

    Ivan Chenchev

    2010-07-01

    Full Text Available Objective: The purpose of this presentation is to show the difficulty in prosthetization of a clinical case with a pronounced atrophy of the upper jaw and the various types and nature of restrictions imposed by the requirements of the patient. Methods: The clinical analysis, surgical protocol and prosthetic solution are presented in the treatment of 72 year-old woman with a pronounced atrophy of the upper jaw. OPG, standard CT of the upper jaw was used in the planning and a special surgical template was fabricated, helping us to find intraoperatively the exact locations of implants. The preliminary analysis of the number, height and diameter of intraossal implants helped us to find the exact prosthetic solution in this clinical case. The preparation of the implant bed was done by conical osteotomy in order to expand and condense the existing bone, which allowed us to use endoossal implants with a possible maximum size in a very limited maxillary volume and the reluctance of the patient to use other methods and surgical techniques. Conical threaded and self-tapping intraossal implants were used, placed according to a classic two-stage methodology with a flap and a long-term functional loading after a period of four months.Results and Conclusion: The applied surgical and prosthetic solution allowed us to achieve a good functional and aesthetic rehabilitation in this case of severe atrophy of the upper jaw, following a number of restrictions imposed on us by the reluctance of the patient to use other surgical solutions. This shows that in the case of severe atrophy of the upper jaw, a good clinical result can be achieved. For this reason, the use of CT,a well-planned surgical template, sufficient preparation ,the maximum use of available bone volume and the choice of a good prosthetic solution is very important.

  2. The effect of platelet-rich fibrin on implant stability.

    Science.gov (United States)

    Öncü, Elif; Alaaddinoğlu, E Emine

    2015-01-01

    Achieving accelerated implant osseointegration could make immediate or early loading of implants more predictable. Platelet-rich fibrin (PRF) is frequently used to accelerate soft and hard tissue healing. The activated platelets in PRF release growth factors, resulting in cellular proliferation, collagen synthesis, and osteoid production. The aim of this study was to compare the stability of dental implants inserted in a one-stage surgical protocol with or without PRF application. Twenty healthy patients with adequate alveolar bone and two or more adjacent missing teeth extracted at least 6 months previously were included in this study. A minimum of two tapered implants (Ankylos, Dentsply/Friadent) were placed in each patient. After surgical preparation of the implant sockets, PRF that had been prepared preoperatively was placed randomly into one of the sockets (PRF+). The acellular plasma portion of PRF was used to wet the implant placed into the PRF-coated socket. Resonance frequency measurements were made after implant placement and at 1 week and 1 month postoperatively. Mean implant stability quotients (ISQs) of the PRF+ implants was 69.3 ± 10.5, and mean ISQs for the PRF- implants was 64.5 ± 12.2 at the end of the first week. The mean ISQs at 4 weeks postoperatively were 77.1 ± 7.1 for the PRF+ group and 70.5 ± 7.7 for the PRF- group. In this study, PRF application increased implant stability during the early healing period, as evidenced by higher ISQ values. Simple application of this material seems to provide faster osseointegration.

  3. Device-length changes and implant function following surgical implantation of the KineSpring in cadaver knees

    Directory of Open Access Journals (Sweden)

    McNicholas MJ

    2015-01-01

    Full Text Available Michael J McNicholas,1 Stefan M Gabriel,2 Anton G Clifford,2 Evelyne M Hasler2 1Aintree University Hospital, Teaching Hospital, Major Trauma Centre, NHS Foundation Trust, Liverpool, UK; 2Moximed, Hayward, CA, USA Introduction: The KineSpring implant system has been shown to provide load reductions at the medial compartment of the knee, and has demonstrated clinical success in reducing pain and increasing function in patients with medial knee osteoarthritis. These results depend on the ability of the KineSpring to rotate, lengthen, and shorten to accommodate knee motions, and in response to knee position and loading. Purpose: The present study was undertaken to determine length changes of the implanted KineSpring in response to a range of knee positions, external knee loads, and placements by different orthopedic surgeons. Materials and methods: KineSpring system components were implanted in ten cadaver leg specimens by ten orthopedic surgeons, and absorber-length changes were measured under combined loading and in different positions of the knee. Results and conclusion: Spring compression consistent with knee-load reduction, and device lengthening and shortening to accommodate knee loads and motions were seen. These confirm the functionality of the KineSpring when implanted medially to the knee. Keywords: KineSpring, knee, function, preservation, offloading, osteoarthritis

  4. The Effect of Price on Surgeons' Choice of Implants: A Randomized Controlled Survey.

    Science.gov (United States)

    Wasterlain, Amy S; Melamed, Eitan; Bello, Ricardo; Karia, Raj; Capo, John T

    2017-08-01

    Surgical costs are under scrutiny and surgeons are being held increasingly responsible for cost containment. In some instances, implants are the largest component of total procedure cost, yet previous studies reveal that surgeons' knowledge of implant prices is poor. Our study aims to (1) understand drivers behind implant selection and (2) assess whether educating surgeons about implant costs affects implant selection. We surveyed 226 orthopedic surgeons across 6 continents. The survey presented 8 clinical cases of upper extremity fractures with history, radiographs, and implant options. Surgeons were randomized to receive either a version with each implant's average selling price ("price-aware" group), or a version without prices ("price-naïve" group). Surgeons selected a surgical implant and ranked factors affecting implant choice. Descriptive statistics and univariate, multivariable, and subgroup analyses were performed. For cases offering implants within the same class (eg, volar locking plates), price-awareness reduced implant cost by 9% to 11%. When offered different models of distal radius volar locking plates, 25% of price-naïve surgeons selected the most expensive plate compared with only 7% of price-aware surgeons. For cases offering different classes of implants (eg, plate vs external fixator), there was no difference in implant choice between price-aware and price-naïve surgeons. Familiarity with the implant was the most common reason for choosing an implant in both groups (35% vs 46%). Price-aware surgeons were more likely to rank cost as a factor (29% vs 21%). Price awareness significantly influences surgeons' choice of a specific model within the same implant class. Merely including prices with a list of implants leads surgeons to select less expensive implants. This implies that an untapped opportunity exists to reduce surgical expenditures simply by enhancing surgeons' cost awareness. Economic/Decision Analyses I. Copyright © 2017 American

  5. Multiple methods of surgical treatment combined with primary IOL implantation on traumatic lens subluxation/dislocation in patients with secondary glaucoma

    Directory of Open Access Journals (Sweden)

    Rui Wang

    2014-04-01

    Full Text Available AIM:To describe clinical findings and complications from cases of traumatic lens subluxation/dislocation in patients with secondary glaucoma, and discuss the multiple treating methods of operation combined with primary intraocular lens (IOL implantation.METHODS:Non-comparative retrospective observational case series. Participants:30 cases (30 eyes of lens subluxation/dislocation in patients with secondary glaucoma were investigated which accepted the surgical treatment by author in the Ophthalmology of Xi''an No.4 Hospital from 2007 to 2011. According to the different situations of lens subluxation/dislocation, various surgical procedures were performed such as crystalline lens phacoemulsification, crystalline lens phacoemulsification combined anterior vitrectomy, intracapsular cataract extraction combined anterior vitrectomy, lensectomy combined anterior vitrectomy though peripheral transparent cornea incision, pars plana lensectomy combined pars plana vitrectomy, and intravitreal cavity crystalline lens phacofragmentation combined pars plana vitrectomy. And whether to implement trabeculectomy depended on the different situations of secondary glaucoma. The posterior chamber intraocular lenses (PC-IOLs were implanted in the capsular-bag or trassclerally sutured in the sulus decided by whether the capsular were present. Main outcome measures:visual acuity, intraocular pressure, the situation of intraocular lens and complications after the operations.RESULTS: The follow-up time was 11-36mo (21.4±7.13. Postoperative visual acuity of all eyes were improved; 28 cases maintained IOP below 21 mm Hg; 2 cases had slightly IOL subluxation, 4 cases had slightly tilted lens optical area; 1 case had postoperative choroidal detachment; 4 cases had postoperative corneal edema more than 1wk, but eventually recovered transparent; 2 cases had mild postoperative vitreous hemorrhage, and absorbed 4wk later. There was no postoperative retinal detachment, IOL

  6. Graft infections after surgical aortic reconstructions

    OpenAIRE

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open surgical reconstructions as first line of treatment for aorto-iliac diseases. Nowadays, open reconstructions are primarily reserved for patients unsuitable for endovascular reconstructions or for redo ...

  7. Application of digital diagnostic impression, virtual planning, and computer-guided implant surgery for a CAD/CAM-fabricated, implant-supported fixed dental prosthesis: a clinical report.

    Science.gov (United States)

    Stapleton, Brandon M; Lin, Wei-Shao; Ntounis, Athanasios; Harris, Bryan T; Morton, Dean

    2014-09-01

    This clinical report demonstrated the use of an implant-supported fixed dental prosthesis fabricated with a contemporary digital approach. The digital diagnostic data acquisition was completed with a digital diagnostic impression with an intraoral scanner and cone-beam computed tomography with a prefabricated universal radiographic template to design a virtual prosthetically driven implant surgical plan. A surgical template fabricated with computer-aided design and computer-aided manufacturing (CAD/CAM) was used to perform computer-guided implant surgery. The definitive digital data were then used to design the definitive CAD/CAM-fabricated fixed dental prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Impact of cone-beam computed tomography on implant planning and on prediction of implant size

    Energy Technology Data Exchange (ETDEWEB)

    Pedroso, Ludmila Assuncao de Mello; Silva, Maria Alves Garcia Santos, E-mail: ludmilapedroso@hotmail.com [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia; Garcia, Robson Rodrigues [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Medicina Oral; Leles, Jose Luiz Rodrigues [Universidade Paulista (UNIP), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Cirurgia; Leles, Claudio Rodrigues [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Fac. de Odontologia. Dept. de Prevencao e Reabilitacao Oral

    2013-11-15

    The aim was to investigate the impact of cone-beam computed tomography (CBCT) on implant planning and on prediction of final implant size. Consecutive patients referred for implant treatment were submitted to clinical examination, panoramic (PAN) radiography and a CBCT exam. Initial planning of implant length and width was assessed based on clinical and PAN exams, and final planning, on CBCT exam to complement diagnosis. The actual dimensions of the implants placed during surgery were compared with those obtained during initial and final planning, using the McNemmar test (p < 0.05). The final sample comprised 95 implants in 27 patients, distributed over the maxilla and mandible. Agreement in implant length was 50.5% between initial and final planning, and correct prediction of the actual implant length was 40.0% and 69.5%, using PAN and CBCT exams, respectively. Agreement in implant width assessment ranged from 69.5% to 73.7%. A paired comparison of the frequency of changes between initial or final planning and implant placement (McNemmar test) showed greater frequency of changes in initial planning for implant length (p < 0.001), but not for implant width (p = 0.850). The frequency of changes was not influenced by implant location at any stage of implant planning (chi-square test, p > 0.05). It was concluded that CBCT improves the ability of predicting the actual implant length and reduces inaccuracy in surgical dental implant planning. (author)

  9. “In vitro” Implantation Technique Based on 3D Printed Prosthetic Prototypes

    Science.gov (United States)

    Tarnita, D.; Boborelu, C.; Geonea, I.; Malciu, R.; Grigorie, L.; Tarnita, D. N.

    2018-06-01

    In this paper, Rapid Prototyping ZCorp 310 system, based on high-performance composite powder and on resin-high strength infiltration system and three-dimensional printing as a manufacturing method are used to obtain physical prototypes of orthopaedic implants and prototypes of complex functional prosthetic systems directly from the 3D CAD data. These prototypes are useful for in vitro experimental tests and measurements to optimize and obtain final physical prototypes. Using a new elbow prosthesis model prototype obtained by 3D printing, the surgical technique of implantation is established. Surgical implantation was performed on male corpse elbow joint.

  10. Results of a prospective surgical audit of bilateral paediatric cochlear implantation in the UK.

    Science.gov (United States)

    Broomfield, Stephen J; Murphy, John; Wild, Dominik C; Emmett, Stevan R; O'Donoghue, Gerard M

    2014-09-01

    Since being approved in 2009, bilateral simultaneous cochlear implantation (CI) has been the standard treatment for children in the UK who meet the criteria for CI. The aim was to report surgical outcomes of bilateral CI in the UK. Between January 2010 and December 2011, 14 UK CI centres collected data prospectively: demographics, aetiology, use of imaging, device type, surgery duration, use of intra-operative electrophysiology, length of stay, and post-operative complications. 1397 CI procedures in 961 CI recipients were included; 436 bilateral simultaneous, 394 bilateral sequential, and 131 unilateral. The majority (85%) were congenitally deaf. The commonest causes of acquired deafness were meningitis and cytomegalovirus infection. The median age for congenitally deaf bilateral simultaneous CI was 2.2 years, mean surgical duration 4.5 hours. 6.3% surgeries were day case procedures. Eight cases (2.0%) of planned bilateral CI had unilateral surgery. The overall major complication rate was 1.6% (0.9% excluding device failures), including explantation due to infection (0.2%), cerebrospinal fluid leak (0.2%), and meningitis (0.1%). There were no permanent facial nerve palsies and no deaths. Sixty-two (6.5%) immediate minor complications included 12 (1.3%) children with significant vestibular impairment. The complication rate was similar following bilateral CI compared to sequential and unilateral CI, and is comparable to other published series. This prospective multi-centre audit provides evidence that bilateral paediatric CI is a safe procedure in the UK, thus endorsing its role as a major therapeutic intervention in childhood deafness.

  11. Evolution of general surgical problems in patients with left ventricular assist devices.

    Science.gov (United States)

    McKellar, Stephen H; Morris, David S; Mauermann, William J; Park, Soon J; Zietlow, Scott P

    2012-11-01

    Left ventricular assist devices (LVADs) are increasingly used to treat patients with end-stage heart failure. These patients may develop acute noncardiac surgical problems around the time of LVAD implantation or, as survival continues to improve, chronic surgical problems as ambulatory patients remote from the LVAD implant. Previous reports of noncardiac surgical problems in LVAD patients included patients with older, first-generation devices and do not address newer, second-generation devices. We describe the frequency and management of noncardiac surgical problems encountered during LVAD support with these newer-generation devices to assist noncardiac surgeons involved in the care of patients with LVADs. We retrospectively reviewed the medical records of consecutive patients receiving LVADs at our institution. We collected data for any consultation by noncardiac surgeons within the scope of general surgery during LVAD support and subsequent treatment. Ninety-nine patients received implantable LVADs between 2003 and 2009 (first-generation, n = 19; second-generation, n = 80). Excluding intestinal hemorrhage, general surgical opinions were rendered for 34 patients with 49 problems, mostly in the acute recovery phase after LVAD implantation. Of those, 27 patients underwent 28 operations. Respiratory failure and intra-abdominal pathologies were the most common problems addressed, and LVAD rarely precluded operation. Patients with second-generation LVADs were more likely to survive hospitalization (P = .04) and develop chronic, rather than emergent, surgical problems. Patients with LVADs frequently require consultation from noncardiac surgeons within the scope of general surgeons and often require operation. Patients with second-generation LVADs are more likely to become outpatients and develop more elective surgical problems. Noncardiac surgeons will be increasingly involved in caring for patients with LVADs and should anticipate the problems unique to this patient

  12. Original computer aided support system for safe and accurate implant placement—Collaboration with an university originated venture company

    Directory of Open Access Journals (Sweden)

    Taiji Sohmura

    2010-08-01

    Two clinical cases with implant placement on the three lower molars by flap operation using bone supported surgical guide and flapless operation with teeth supported surgical guide and immediate loading with provisional prostheses prepared beforehand are introduced. The present simulation and drilling support using the surgical guide may help to perform safe and accurate implant surgery.

  13. Imaging technique for the complete edentulous patient treated conventionally or with mini implant overdenture

    Science.gov (United States)

    Meleşcanu Imre, M; Preoteasa, E; Țâncu, AM; Preoteasa, CT

    2013-01-01

    Rationale. The imaging methods are more and more used in the clinical process of modern dentistry. Once the implant based treatment alternatives are nowadays seen as being the standard of care in edentulous patients, these techniques must be integrated in the complete denture treatment. Aim. The study presents some evaluation techniques for the edentulous patient treated by conventional dentures or mini dental implants (mini SKY Bredent) overdentures, using the profile teleradiography. These offer data useful for an optimal positioning of the artificial teeth and the mini dental implants, favoring to obtain an esthetic and functional treatment outcome. We proposed also a method to conceive a simple surgical guide that allows the prosthetically driven implants placement. Material and method. Clinical case reports were made, highlighting the importance of cephalometric evaluation on lateral teleradiographs in complete edentulous patients. A clinical case that gradually reports the surgical guide preparation (Bredent silicon radio opaque), in order to place the mini dental implants in the best prosthetic and anatomic conditions, was presented. Conclusions. The profile teleradiograph is a useful tool for the practitioner. It allows establishing the optimal site for implant placement, in a good relation with the overdenture. The conventional denture can be easily and relatively costless transformed in a surgical guide used during implant placement. PMID:23599828

  14. Quantitative Assessment of Orbital Implant Position--A Proof of Concept.

    Directory of Open Access Journals (Sweden)

    Ruud Schreurs

    Full Text Available In orbital reconstruction, the optimal location of a predefined implant can be planned preoperatively. Surgical results can be assessed intraoperatively or postoperatively. A novel method for quantifying orbital implant position is introduced. The method measures predictability of implant placement: transformation parameters between planned and resulting implant position are quantified.The method was tested on 3 human specimen heads. Computed Tomography scans were acquired at baseline with intact orbits (t0, after creation of the defect (t1 and postoperatively after reconstruction of the defect using a preformed implant (t2. Prior to reconstruction, the optimal implant position was planned on the t0 and t1 scans. Postoperatively, the planned and realized implant position were compared. The t0 and t2 scans were fused using iPlan software and the resulting implant was segmented in the fused t2 scan. An implant reference frame was created (Orbital Implant Positioning Frame; the planned implant was transformed to the reference position using an Iterative Closest Point approach. The segmentation of the resulting implant was also registered on the reference position, yielding rotational (pitch, yaw, roll as well as translational parameters of implant position.Measurement with the Orbital Implant Positioning Frame proved feasible on all three specimen. The positional outcome provided more thorough and accurate insight in resulting implant position than could be gathered from distance measurements alone. Observer-related errors were abolished from the process, since the method is largely automatic.A novel method of quantifying surgical outcome in orbital reconstructive surgery was presented. The presented Orbital Implant Positioning Frame assessed all parameters involved in implant displacement. The method proved to be viable on three human specimen heads. Clinically, the method could provide direct feedback intraoperatively and could improve

  15. The acquisition of personal pronouns in cochlear-implanted children

    NARCIS (Netherlands)

    Verbist, Annemie Josee Jozef

    2010-01-01

    Today, many deaf children can be given access to oral language thanks to a cochlear implant, a surgically implanted electronic device that provides a sense of sound thanks to electric stimulation of the auditory nerve. In this study, the acquisition of personal pronouns is considered to be a measure

  16. Computed Tomographic Analysis of Ventral Atlantoaxial Optimal Safe Implantation Corridors in 27 Dogs.

    Science.gov (United States)

    Leblond, Guillaume; Gaitero, Luis; Moens, Noel M M; Zur Linden, Alex; James, Fiona M K; Monteith, Gabrielle J; Runciman, John

    2017-11-01

    Objectives  Ventral atlantoaxial stabilization techniques are challenging surgical procedures in dogs. Available surgical guidelines are based upon subjective anatomical landmarks, and limited radiographic and computed tomographic data. The aims of this study were (1) to provide detailed anatomical descriptions of atlantoaxial optimal safe implantation corridors to generate objective recommendations for optimal implant placements and (2) to compare anatomical data obtained in non-affected Toy breed dogs, affected Toy breed dogs suffering from atlantoaxial instability and non-affected Beagle dogs. Methods  Anatomical data were collected from a prospectively recruited population of 27 dogs using a previously validated method of optimal safe implantation corridor analysis using computed tomographic images. Results  Optimal implant positions and three-dimensional numerical data were generated successfully in all cases. Anatomical landmarks could be used to generate objective definitions of optimal insertion points which were applicable across all three groups. Overall the geometrical distribution of all implant sites was similar in all three groups with a few exceptions. Clinical Significance  This study provides extensive anatomical data available to facilitate surgical planning of implant placement for atlantoaxial stabilization. Our data suggest that non-affected Toy breed dogs and non-affected Beagle dogs constitute reasonable research models to study atlantoaxial stabilization constructs. Schattauer GmbH Stuttgart.

  17. Osseointegration of Plateau Root Form Implants: Unique Healing Pathway Leading to Haversian-Like Long-Term Morphology.

    Science.gov (United States)

    Coelho, Paulo G; Suzuki, Marcelo; Marin, Charles; Granato, Rodrigo; Gil, Luis F; Tovar, Nick; Jimbo, Ryo; Neiva, Rodrigo; Bonfante, Estevam A

    2015-01-01

    Endosteal dental implants have been utilized as anchors for dental and orthopedic rehabilitations for decades with one of the highest treatment success rates in medicine. Such success is due to the phenomenon of osseointegration where after the implant surgical placement, bone healing results into an intimate contact between bone and implant surface. While osseointegration is an established phenomenon, the route which osseointegration occurs around endosteal implants is related to various implant design factors including surgical instrumentation and implant macro, micro, and nanometer scale geometry. In an implant system where void spaces (healing chambers) are present between the implant and bone immediately after placement, its inherent bone healing pathway results in unique opportunities to accelerate the osseointegration phenomenon at the short-term and its maintenance on the long-term through a haversian-like bone morphology and mechanical properties.

  18. Three-Dimensional Implant Positioning with a Piezosurgery Implant Site Preparation Technique and an Intraoral Surgical Navigation System: Case Report.

    Science.gov (United States)

    Pellegrino, Gerardo; Taraschi, Valerio; Vercellotti, Tomaso; Ben-Nissan, Besim; Marchetti, Claudio

    This case report describes new implant site preparation techniques joining the benefits of using an intraoral navigation system to optimize three-dimensional implant site positioning in combination with an ultrasonic osteotomy. A report of five patients is presented, and the implant positions as planned in the navigation software with the postoperative scan image were compared. The preliminary results are useful, although further clinical studies with larger populations are needed to confirm these findings.

  19. [Guided and computer-assisted implant surgery and prosthetic: The continuous digital workflow].

    Science.gov (United States)

    Pascual, D; Vaysse, J

    2016-02-01

    New continuous digital workflow protocols of guided and computer-assisted implant surgery improve accuracy of implant positioning. The design of the future prosthesis is based on the available prosthetic space, gingival height and occlusal relationship with the opposing and adjacent teeth. The implant position and length depend on volume, density and bone quality, gingival height, tooth-implant and implant-implant distances, implant parallelism, axis and type of the future prosthesis. The crown modeled on the software will therefore serve as a guide to the future implant axis and not the reverse. The guide is made by 3D printing. The software determines surgical protocol with the drilling sequences. The unitary or plural prosthesis, modeled on the software and built before surgery, is loaded directly after implant placing, if needed. These protocols allow for a full continuity of the digital workflow. The software provides the surgeon and the dental technician a total freedom for the prosthetic-surgery guide design and the position of the implants. The prosthetic project, occlusal and aesthetic, taking the bony and surgical constraints into account, is optimized. The implant surgery is simplified and becomes less "stressful" for the patient and the surgeon. Guided and computer-assisted surgery with continuous digital workflow is becoming the technique of choice to improve the accuracy and quality of implant rehabilitation. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  20. Computer-aided insertion of endosteal implants in the zygoma: a pilot study

    Science.gov (United States)

    Birkfellner, Wolfgang; Watzinger, Franz; Wanschitz, Felix; Ziya, F.; Kremser, J.; Potyka, A.; Mayr, R.; Huber, Klaus; Kainberger, F.; Ewers, Rolf; Bergmann, Helmar

    2000-04-01

    Endosteal implants facilitate obturator prosthesis fixation in tumor patients after maxillectomy. Previous clinical studies shown however, that survival of implants placed into available bone after maxillectomy is generally poor. Implants positioned optimally in residual zygomatic bone provide superior stability form a biomechanical point of view as well as improved survival. In a pilot study, we have assessed the precision of VISIT, a surgical navigation system developed for research purposes at our institution. VISIT is based on the AVW-library and a number of in-house developed algorithms for communication with an optical tracker and patient-to-CT-registration. The final platform independent application was assembled within 6 man-months using ANSI-C and Tcl/Tk. Five cadaver specimens underwent hemimaxillectomy. The cadaver head was matched to a preoperative high resolution CT by using implanted surgical microscrews as fiducial markers. The position of a surgical drill relative to the cadaver head was determined with an optical tracking system. Implants were placed into the zygomatic arch where maximum bone volume was available. The results were assessed using test for allocation accuracy and postoperative CT-scans of the cadaver specimens. The average allocation accuracy of landmarks on the bony skull was 0.6 +/- 0.3 mm determined with a 5 degree-of-freedom pointer probe. The allocation accuracy of the tip of the implant burr was 1.7 +/- 0.4 mm. The accuracy of the implant position compared to the planned position was 1.5 +/- 1.1 mm. 8 out of 10 implants were inserted with maximum contact to surrounding bone, two implants were located unfavorably. However, reliable placement of implants in this region is difficult to achieve. The techqni3u described in this paper may be very helpful in the management of patients after maxillary resection without sufficient retention for obturator prostheses.

  1. Split-mouth comparison of the accuracy of computer-generated and conventional surgical guides.

    Science.gov (United States)

    Farley, Nathaniel E; Kennedy, Kelly; McGlumphy, Edwin A; Clelland, Nancy L

    2013-01-01

    Recent clinical studies have shown that implant placement is highly predictable with computer-generated surgical guides; however, the reliability of these guides has not been compared to that of conventional guides clinically. This study aimed to compare the accuracy of reproducing planned implant positions with computer-generated and conventional surgical guides using a split-mouth design. Ten patients received two implants each in symmetric locations. All implants were planned virtually using a software program and information from cone beam computed tomographic scans taken with scan appliances in place. Patients were randomly selected for computer-aided design/computer-assisted manufacture (CAD/CAM)-guided implant placement on their right or left side. Conventional guides were used on the contralateral side. Patients underwent operative cone beam computed tomography postoperatively. Planned and actual implant positions were compared using three-dimensional analyses capable of measuring volume overlap as well as differences in angles and coronal and apical positions. Results were compared using a mixed-model repeated-measures analysis of variance and were further analyzed using a Bartlett test for unequal variance (α = .05). Implants placed with CAD/CAM guides were closer to the planned positions in all eight categories examined. However, statistically significant differences were shown only for coronal horizontal distances. It was also shown that CAD/CAM guides had less variability than conventional guides, which was statistically significant for apical distance. Implants placed using CAD/CAM surgical guides provided greater accuracy in a lateral direction than conventional guides. In addition, CAD/CAM guides were more consistent in their deviation from the planned locations than conventional guides.

  2. Transforming growth factor-beta1 adsorbed to tricalciumphosphate coated implants increases peri-implant bone remodeling

    DEFF Research Database (Denmark)

    Lin, M.; Overgaard, S; Glerup, H

    2001-01-01

    inserted bilaterally into the femoral condyles of 10 skeletally mature mongrel dogs. The implants were initially surrounded by a 2 mm gap. Implants with 0.3 microg rhTGF-beta1 were compared with implants without growth factor. The dogs were sacrificed after six weeks. Bone remodeling was evaluated...... by histomorphometry on Goldner-stained undecalcified sections. The bone volume in the gap was increased significantly from 17.6% in the control group to 25.6% in the rhTGF-beta1 group (p = 0.03). Also bone surface was increased in the rhTGF-beta1 group. The osteoclast covered surfaces were increased from 3.......6% in the control group to 5.9% in the rhTGF-beta1 group (p = 0.02). In the surrounding trabecular bone no significant changes in bone remodeling parameters was demonstrated. This study suggests that rhTGF-beta1 adsorbed onto TCP-ceramic coated implants accelerates repair activity in the newly formed bone close...

  3. Implant rehabilitation of partial maxillectomy edentulous patien

    Directory of Open Access Journals (Sweden)

    Mahesh E Gowda

    2013-01-01

    Full Text Available Edentulous patients with maxillectomy defects present a significant challenge for prosthetic rehabilitation and the adaptive capabilities of the patient as retention is highly compromised. Hence, the option of using endosseous implants to increase obturator retention has been used. A patient of mucormycosis of the left maxilla was treated with surgical excision. After satisfactory healing, definitive implant supported magnet retained prosthesis was fabricated for the patient. Implants with magnetic units offer a practical method of improving the retention of obturators provided acceptable prosthetic protocols are followed for the rehabilitation.

  4. Implant rehabilitation of partial maxillectomy edentulous patient

    Science.gov (United States)

    Gowda, Mahesh E.; Mohan, Murali S.; Verma, Kamal; Roy, I. D.

    2013-01-01

    Edentulous patients with maxillectomy defects present a significant challenge for prosthetic rehabilitation and the adaptive capabilities of the patient as retention is highly compromised. Hence, the option of using endosseous implants to increase obturator retention has been used. A patient of mucormycosis of the left maxilla was treated with surgical excision. After satisfactory healing, definitive implant supported magnet retained prosthesis was fabricated for the patient. Implants with magnetic units offer a practical method of improving the retention of obturators provided acceptable prosthetic protocols are followed for the rehabilitation. PMID:24124314

  5. Ahmed Glaucoma Valve Implantation in Vitrectomized Eyes

    OpenAIRE

    Erçalık, Nimet Yeşim; İmamoğlu, Serhat

    2018-01-01

    Purpose. To evaluate the outcomes of Ahmed glaucoma valve (AGV) implantation in vitrectomized eyes. Materials and Methods. The medical records of 13 eyes that developed glaucoma due to emulsified silicon oil or neovascularization following pars plana vitrectomy and underwent AGV implantation were retrospectively reviewed. The main outcome measures were intraocular pressure (IOP), best-corrected visual acuity (BCVA), number of antiglaucoma medications, and postoperative complications. Surgical...

  6. Retrospective analysis of 56 edentulous dental arches restored with 344 single-stage implants using an immediate loading fixed provisional protocol: statistical predictors of implant failure.

    Science.gov (United States)

    Kinsel, Richard P; Liss, Mindy

    2007-01-01

    The purpose of this retrospective study was to evaluate the effects of implant dimensions, surface treatment, location in the dental arch, numbers of supporting implant abutments, surgical technique, and generally recognized risk factors on the survival of a series of single-stage Straumann dental implants placed into edentulous arches using an immediate loading protocol. Each patient received between 4 and 18 implants in one or both dental arches. Periapical radiographs were obtained over a 2- to 10-year follow-up period to evaluate crestal bone loss following insertion of the definitive metal-ceramic fixed prostheses. Univariate tests for failure rates as a function of age ( or = 60 years), gender, smoking, bone grafting, dental arch, surface type, anterior versus posterior, number of implants per arch, and surgical technique were made using Fisher exact tests. The Cochran-Armitage test for trend was used to evaluate the presence of a linear trend in failure rates regarding implant length and implant diameter. Logistic regression modeling was used to determine which, if any, of the aforementioned factors would predict patient and implant failure. A significance criterion of P = .05 was utilized. Data were collected for 344 single-stage implants placed into 56 edentulous arches (39 maxillae and 17 mandibles) of 43 patients and immediately loaded with a 1-piece provisional fixed prosthesis. A total of 16 implants failed to successfully integrate, for a survival rate of 95.3%. Increased rates of failure were associated with reduced implant length, placement in the posterior region of the jaw, increased implant diameter, and surface treatment. Implant length emerged as the sole significant predictor of implant failure. In this retrospective analysis of 56 consecutively treated edentulous arches with multiple single-stage dental implants loaded immediately, reduced implant length was the sole significant predictor of failure.

  7. Effect of implant macro-design on primary stability: A prospective clinical study

    OpenAIRE

    Lozano-Carrascal, Naroa; Salom?-Coll, Oscar; Gilabert-Cerd?, Marta; Farr?-Pag?s, Nuria; Gargallo-Albiol, Jordi; Hern?ndez-Alfaro, Federico

    2016-01-01

    Background Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Methods A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS? Seven implants; Control group...

  8. Cranioplasty with individual titanium implants

    Science.gov (United States)

    Mishinov, S.; Stupak, V.; Sadovoy, M.; Mamonova, E.; Koporushko, N.; Larkin, V.; Novokshonov, A.; Dolzhenko, D.; Panchenko, A.; Desyatykh, I.; Krasovsky, I.

    2017-09-01

    Cranioplasty is the second procedure in the history of neurosurgery after trepanation, and it is still relevant despite the development of civilization and progress in medicine. Each cranioplasty operation is unique because there are no two patients with identical defects of the skull bones. The development of Direct Metal Laser Sintering (DMLS) technique opened up the possibility of direct implant printing of titanium, a biocompatible metal used in medicine. This eliminates the need for producing any intermediate products to create the desired implant. We have produced 8 patient-specific titanium implants using this technique for patients who underwent different decompressive cranioectomies associated with bone tumors. Follow-up duration ranged from 6 to 12 months. We observed no implant-related reactions or complications. In all cases of reconstructive neurosurgery we achieved good clinical and aesthetic results. The analysis of the literature and our own experience in three-dimensional modeling, prototyping, and printing suggests that direct laser sintering of titanium is the optimal method to produce biocompatible surgical implants.

  9. Influence of prosthesis design and implantation technique on implant stresses after cementless revision THR

    Directory of Open Access Journals (Sweden)

    Duda Georg N

    2011-05-01

    Full Text Available Abstract Background Femoral offset influences the forces at the hip and the implant stresses after revision THR. For extended bone defects, these forces may cause considerable bending moments within the implant, possibly leading to implant failure. This study investigates the influences of femoral anteversion and offset on stresses in the Wagner SL revision stem implant under varying extents of bone defect conditions. Methods Wagner SL revision stems with standard (34 mm and increased offset (44 mm were virtually implanted in a model femur with bone defects of variable extent (Paprosky I to IIIb. Variations in surgical technique were simulated by implanting the stems each at 4° or 14° of anteversion. Muscle and joint contact forces were applied to the reconstruction and implant stresses were determined using finite element analyses. Results Whilst increasing the implant's offset by 10 mm led to increased implant stresses (16.7% in peak tensile stresses, altering anteversion played a lesser role (5%. Generally, larger stresses were observed with reduced bone support: implant stresses increased by as much as 59% for a type IIIb defect. With increased offset, the maximum tensile stress was 225 MPa. Conclusion Although increased stresses were observed within the stem with larger offset and increased anteversion, these findings indicate that restoration of offset, key to restoring joint function, is unlikely to result in excessive implant stresses under routine activities if appropriate fixation can be achieved.

  10. Osseointegrated implants and auricular defects: a case series study.

    Science.gov (United States)

    Wright, Robert F; Zemnick, Candice; Wazen, Jack J; Asher, Eric

    2008-08-01

    The objective of this study was to report on the survival rate of 16 patients treated with extraoral implants in the auricular region, analyze treatment outcomes, and discuss important clinical variables encountered during treatment. Sixteen patients who received extraoral dental implants to retain auricular prostheses between 1987 and 2003 were followed retrospectively. The variables recorded were gender, initial diagnosis, number and size of implants, implant placement date, age at implant placement, history of radiation to the treated field, abutment size, design of initial prosthesis, age of initial prosthesis (when a remake was indicated), date of prosthesis delivery, soft tissue response, grafting procedure, date of last follow-up, and complications. All patients were thoroughly evaluated presurgically by the reconstruction team, which consisted of prosthodontists, a facial prosthetist, and an otolaryngologist. Surgical templates were used for all patients. The criteria for success of the prostheses included marginal accuracy, overall stability and function, symmetry/position, texture, color stability, and patient acceptance. Thirty-nine implants were placed in 16 patients. All 16 patients were completely satisfied with their reconstructions. No surgical complications, implant failures, or prosthetic failures were encountered. Therefore, the survival rate was 100%. Three patients (18.75%) had grade 0, seven (43.75%) had grade 1, five (31.25%) had grade 2, and one (6.25%) had grade 3 soft tissue inflammation. The inflammation completely resolved in 7 of the 13 patients (54%) with hygiene reinforcement or soft tissue reduction. The survival rate for bone-anchored titanium implants and prostheses was 100%. Bone-anchored titanium implants provided the 16 patients in this study with a safe, reliable, adhesive-free method to anchor auricular prostheses with recovery of normal appearance. Under the guidance of an appropriate implant team, proper positioning of

  11. Mechanical Properties of a Newly Additive Manufactured Implant Material Based on Ti-42Nb.

    Science.gov (United States)

    Schulze, Christian; Weinmann, Markus; Schweigel, Christoph; Keßler, Olaf; Bader, Rainer

    2018-01-13

    The application of Ti-6Al-4V alloy or commercially pure titanium for additive manufacturing enables the fabrication of complex structural implants and patient-specific implant geometries. However, the difference in Young's modulus of α + β-phase Ti alloys compared to the human bone promotes stress-shielding effects in the implant-bone interphase. The aim of the present study is the mechanical characterization of a new pre-alloyed β-phase Ti-42Nb alloy for application in additive manufacturing. The present investigation focuses on the mechanical properties of SLM-printed Ti-42Nb alloy in tensile and compression tests. In addition, the raw Ti-42Nb powder, the microstructure of the specimens prior to and after compression tests, as well as the fracture occurring in tensile tests are characterized by means of the SEM/EDX analysis. The Ti-42Nb raw powder exhibits a dendrite-like Ti-structure, which is melted layer-by-layer into a microstructure with a very homogeneous distribution of Nb and Ti during the SLM process. Tensile tests display Young's modulus of 60.51 ± 3.92 GPa and an ultimate tensile strength of 683.17 ± 16.67 MPa, whereas, under a compressive load, a compressive strength of 1330.74 ± 53.45 MPa is observed. The combination of high mechanical strength and low elastic modulus makes Ti-42Nb an interesting material for orthopedic and dental implants. The spherical shape of the pre-alloyed material additionally allows for application in metal 3D printing, enabling the fabrication of patient-specific structural implants.

  12. Surgical treatment of complications associated with the Angio-Seal vascular closure device.

    Science.gov (United States)

    Cikirikcioglu, Mustafa; Cherian, Sanjay; Keil, Vera; Manzano, Norman; Gemayel, Gino; Theologou, Thomas; Kalangos, Afksendiyos

    2011-05-01

    Vascular closure devices are used to provide quick hemostasis and early ambulation after percutaneous interventions. The Angio-Seal (AS) vascular closure device forms a mechanical seal by closing the puncture site located between a bioabsorbable anchor within the lumen and a collagen sponge on the adventitia. Although morbidities associated with AS are reportedly infrequent, even the slightest inaccuracy in device implantation may result in displacement of these device components, leading to sudden and severe complications. We report the surgical treatment of complications associated with the use of AS in four patients, including acute limb ischemia, pseudoaneurysm formation, significant hemorrhage, and hypovolemic shock. A common factor in all these cases was that the components of the AS device were displaced from their original site of implantation, stressing the importance of proper device placement. All patients underwent successful surgical vascular repair. Our report highlights the need for exercising extreme care during device implantation, and also the requirement for vigilant inspection for any associated vascular complications commencing immediately after device implantation. It is vital that these device components are actively looked for and removed during surgical exploration so as to prevent future complications. Copyright © 2011. Published by Elsevier Inc.

  13. Maxillary "All-On-Four" treatment using zygomatic implants. A mechanical analysis.

    Science.gov (United States)

    de Moraes, P H; Olate, S; Nóbilo, M de Arruda; Asprino, L; de Moraes, M; Barbosa, J de Albergaría

    2016-04-01

    Zygomatic implants may be used for dental rehabilitation in atrophic maxillae. The aim of this study was to establish experimentally the areas of stress distribution using 2 kinds of "All-On-Four" maxillary procedures. The best position to insert the implants was selected using polyurethane craniomaxillary models and surgical guides were made. Group 1 was designed with two posterior zygomatic implants and two conventional anterior implants, and group 2 with two posterior zygomatic implants and two anterior zygomatic implants. A titanium bar was built to link the 4 implants in both groups. Photoelastic replicas of these models were made and the implants were inserted using the surgical guides. An Instrom 4411 testing machine was used to perform a unilateral compressive loading at the level of the right first molar until 2mm of displacement was obtained. Group 1 showed a high strain concentration in the right lateral orbital region at the level of the apex of the zygomatic implant. Less strain was noticed at the apical levels of the conventional implants in the anterior sector and of the contralateral zygomatic implant. Group 2 showed high strains in the lateral inferior orbital area. The load was low in the alveolar bone sector. Zygomatic bone and paranasal structures are loaded at high levels when zygomatic implants are used to stabilize a full maxillary prosthodontic rehabilitation on 4 implants. The use of 4 zygomatic implants loads the alveolar bone to a lower extent and seems better suited from a mechanical point of view than the use of 2 zygomatic implants. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  14. Structural and mechanical characterization of custom design cranial implant created using additive manufacturing

    OpenAIRE

    Khaja Moiduddin; Saied Darwish; Abdulrahman Al-Ahmari; Sherif ElWatidy; Ashfaq Mohammad; Wadea Ameen

    2017-01-01

    Background: Reconstruction of customized cranial implants with a mesh structure using computer-assisted design and additive manufacturing improves the implant design, surgical planning, defect evaluation, implant-tissue interaction and surgeon's accuracy. The objective of this study is to design, develop and fabricate cranial implant with mechanical properties closer to that of bone and drastically decreases the implant failure and to improve the esthetic outcome in cranial surgery with preci...

  15. Potential applications of biphosphonates in dental surgical implants.

    Science.gov (United States)

    Berardi, D; Carlesi, T; Rossi, F; Calderini, M; Volpi, R; Perfetti, G

    2007-01-01

    Biphosphonates are largely used for their unquestionable properties of inhibiting bone resorption by osteoclasts in the treatment of various osteometabolic illnesses such as osteoporosis, multiple myeloma, tumors which metastasize to the bone and malignant hypercalcemia. In this literature review the physico-chemical properties, biologic activities and the mechanisms of action of biphosphonates are described. The use of these drugs is discussed, analyzing the quantity of results which have emerged through in vitro and in vivo experiments on animal models. In this study the efficiency of these drugs is demonstrated in contrasting the osteolitic processes of the alveolar bone, in promoting the neoformation and in bettering the quality of bone implants. However, it is important to draw attention to a worrying correlation which has emerged during the last 3-4 years, between osteonecrosis of the jaw (ONJ) and the systemic administration of aminobiphosphonates. This collateral effect did not emerge following the use of non-aminobiphosphonates. The aim of this review is to identify the guidelines for the use of biphosphonates in oral implant surgery.

  16. Use of extraocular muscle flaps in the correction of orbital implant exposure.

    Directory of Open Access Journals (Sweden)

    Hsueh-Yen Chu

    Full Text Available PURPOSES: The study is to describe a new surgical technique for correcting large orbital implant exposure with extraocular muscle flaps and to propose a treatment algorithm for orbital implant exposure. METHODS: In a retrospective study, seven patients with orbital implant exposure were treated with extraocular muscle flaps. All data were collected from patients in Chang Gung Memorial Hospital, Taiwan during 2007-2012. All surgeries were performed by one surgeon (Y.J.T. Patient demographics, the original etiology, details of surgical procedures, implant types, and follow-up interval were recorded. Small exposure, defined as exposure area smaller than 3 mm in diameter, was treated conservatively first with topical lubricant and prophylactic antibiotics. Larger defects were managed surgically. RESULTS: Seven patients consisting of two males and five females were successfully treated for orbital implant exposure with extraocular muscle flaps. The average age was 36.4 (range, 3-55 years old. Five patients were referred from other hospitals. One eye was enucleated for retinoblastoma. The other six eyes were eviscerated, including one for endophthalmitis and five for trauma. Mean follow-up time of all seven patients was 19.5 (range, 2-60 months. No patient developed recurrence of exposure during follow-up. All patients were fitted with an acceptable prosthesis and had satisfactory cosmetic and functional results. CONCLUSIONS: The most common complication of orbital implant is exposure, caused by breakdown of the covering layers, leading to extrusion. Several methods were reported to manage the exposed implants. We report our experience of treating implant exposure with extraocular muscle flaps to establish a well-vascularized environment that supplies both the wrapping material and the overlying ocular surface tissue. We believe it can work as a good strategy to manage or to prevent orbital implant exposure.

  17. Comparison of Reconstructive Outcomes in Breast Cancer Patients With Preexisting Subpectoral Implants: Implant-Sparing Mastectomy With Delayed Implant Exchange Versus Immediate Tissue Expander Reconstruction.

    Science.gov (United States)

    Parabkaharan, Sangeetha; Melody, Megan; Trotta, Rose; Lleshi, Amina; Sun, Weihong; Smith, Paul D; Khakpour, Nazanin; Dayicioglu, Deniz

    2016-06-01

    Women who have undergone prior augmentation mammoplasty represent a unique subset of breast cancer patients with several options available for breast reconstruction. We performed a single institution review of surgical outcomes of breast reconstruction performed in patients with breast cancer with prior history of subpectoral breast augmentation. Institutional review board-approved retrospective review was conducted among patients with previously mentioned criteria treated at our institution between 2000 and 2014. Reconstructions were grouped into 2 categories as follows: (1) removal of preexisting subpectoral implant during mastectomy with immediate tissue expander placement and (2) implant-sparing mastectomy followed by delayed exchange to a larger implant. We reviewed demographics, tumor features, and reconstruction outcomes of these groups. Fifty-three patients had preexisting subpectoral implants. Of the 63 breast reconstructions performed, 18 (28.6%) had immediate tissue expander placed and 45 (71.4%) had implant-sparing mastectomy followed by delayed implant exchange. The groups were comparable based on age, body mass index, cancer type, tumor grade, TNM stage at presentation, and hormonal receptor status. No significant difference was noted between tumor margins or subsequent recurrence, mastectomy specimen weight, removed implant volume, volume of implant placed during reconstruction, or time from mastectomy to final implant placement. Rates of complications were significantly higher in the tissue expander group compared to the implant-sparing mastectomy group 7 (38.9%) versus 4 (8.9%) (P = 0.005). Implant-sparing mastectomy with delayed implant exchange in patients with preexisting subpectoral implants is safe and has fewer complications compared to tissue expander placement. There was no difference noted in the final volume of implant placed, time interval for final implant placement, or tumor margins.

  18. Combined Orbital Fractures: Surgical Strategy of Sequential Repair

    Directory of Open Access Journals (Sweden)

    Su Won Hur

    2015-07-01

    Full Text Available BackgroundReconstruction of combined orbital floor and medial wall fractures with a comminuted inferomedial strut (IMS is challenging and requires careful practice. We present our surgical strategy and postoperative outcomes.MethodsWe divided 74 patients who underwent the reconstruction of the orbital floor and medial wall concomitantly into a comminuted IMS group (41 patients and non-comminuted IMS group (33 patients. In the comminuted IMS group, we first reconstructed the floor stably and then the medial wall by using separate implant pieces. In the non-comminuted IMS group, we reconstructed the floor and the medial wall with a single large implant.ResultsIn the follow-up of 6 to 65 months, most patients with diplopia improved in the first-week except one, who eventually improved at 1 year. All patients with an EOM limitation improved during the first month of follow-up. Enophthalmos (displacement, 2 mm was observed in two patients. The orbit volume measured on the CT scans was statistically significantly restored in both groups. No complications related to the surgery were observed.ConclusionsWe recommend the reconstruction of orbit walls in the comminuted IMS group by using the following surgical strategy: usage of multiple pieces of rigid implants instead of one large implant, sequential repair first of the floor and then of the medial wall, and a focus on the reconstruction of key areas. Our strategy of step-by-step reconstruction has the benefits of easy repair, less surgical trauma, and minimal stress to the surgeon.

  19. Micro CT and human histological analysis of a peri-implant osseous defect grafted with porous titanium granules: a case report.

    Science.gov (United States)

    Wohlfahrt, Johan Caspar; Aass, Anne Merete; Ronold, Hans Jacob; Lyngstadaas, Stale Petter

    2011-01-01

    Treatment of peri-implant osseous defects represents a significant challenge for clinicians, and the need to evolve within predictable surgical procedures is important. This case report describes the surgical treatment and grafting with porous titanium granules (PTG) of one patient with a peri-implant osseous defect. The suggested thrombogenic properties of titanium are intriguing from the perspective of osseous reconstructive surgery. In an ongoing randomized clinical trial using PTG for treatment of peri-implant osseous defects, one patient with one test implant was excluded and scheduled for implant removal. The surgical therapy included open flap debridement with surface decontamination with 24% EDTA gel, grafting with PTG, and resubmersion of the implant. After 12 months of healing, the implant with surrounding tissues was excised en bloc and micro CT and histological analyses were performed. Analyses showed PTG in close contact with new bone and with bone growing both into the porosities of the graft material and onto the adjacent implant surface. Element analysis demonstrated calcium and phosphorus in the new tissue embedding the PTG and the implant. Int J Oral Maxillofac Implants 2011;26:e9-e14.

  20. A conceptual knowledge-link model for supporting dental implant process

    OpenAIRE

    Szejka , Anderson Luis; Canciglieri , Osiris ,; Rudek , Marcelo; Panetto , Hervé

    2014-01-01

    International audience; Computer aided techniques widely used as diagnostic and surgical procedures tools are scarcely applied in implantology, which continues using visualization of CT images to define the parameters for dental implant process leaving to the dentist discretion the implant determination, since only the images analysis is non-deterministic. Thus, this research proposes the development of a knowledge-link model integrated to a reasoner system to support dental implant process t...

  1. Study of surgical treatment on neovascular glaucoma

    Directory of Open Access Journals (Sweden)

    Xiao-Nü Liu

    2014-05-01

    Full Text Available AIM: To compare the effect of two surgical methods on neovascular glaucoma(NVG. METHODS: The clinical date of 46 cases(57 eyeswith NVG underwent surgical treatment were retrospectively analyzed and followed-up. Patients were divided into Ahmed glaucoma valve(AGVimplantation group(group A, 24 cases, 31 eyesand semiconductor diode laser transscleral ciliary body photocoagulation(TSCPCgroup(group B, 22cases, 26 eyesaccording to the surgical approach. The intraocular pressure, visual acuity and postoperative complications were compared before and after operation. RESULTS: The intraocular pressure postoperative in two groups were significantly lower than those preoperative(P P>0.05. The changes of visual acuity postoperative showed no statistical difference between the two groups(P>0.05. The postoperative complications of group A was significantly lower than that in group B, in which the incidence of eye pain, anterior chamber bleeding were significant differences between two groups(P CONCLUSION: AGV implantation treatment and TSCPC for NVG are both valid, but AGV implantation is filtration surgery, and TSCPC isciliary body destructive surgery, and the latter has higher rate of postoperative complications.

  2. Aesthetic Surgical Approach for Bone Dehiscence Treatment by Means of Single Implant and Interdental Tissue Regeneration: A Case Report with Five Years of Follow-Up

    Directory of Open Access Journals (Sweden)

    Giorgio Lombardo

    2016-01-01

    Full Text Available The replacement of single anterior teeth by means of endosseous implants implies the achievement of success in restoring both aesthetic and function. However, the presence of wide endoperiodontal lesions can lead to horizontal hard and soft tissues defects after tooth extraction, making it impossible to correctly place an implant in the compromised alveolar socket. Vertical augmentation procedures have been proposed to solve these clinical situations, but the amount of new regenerated bone is still not predictable. Furthermore, bone augmentation can be complicated by the presence of adjacent teeth, especially if they bring with them periodontal defects. Therefore, it is used to restore periodontal health of adjacent teeth before making any augmentation procedures and to wait a certain healing period before placing an implant in vertically augmented sites, otherwise risking to obtain a nonsatisfactory aesthetic result. All of these procedures, however, lead to an expansion of treatment time which should affect patient compliance. For this reason, this case report suggests a surgical technique to perform vertical bone augmentation at a single gap left by a central upper incisor while placing an implant and simultaneously to regenerate the periodontal attachment of an adjacent lateral incisor, without compromising the aesthetic result.

  3. Prosthetic Consideration in Implant-supported Prosthesis: A Review of Literature.

    Science.gov (United States)

    Gowd, Manga Snigdha; Shankar, Thatapudi; Ranjan, Rajeev; Singh, Arpita

    2017-06-01

    Modern dentistry has changed tremendously with implant therapy. For the successful implant therapy, making a proper treatment plan considering both surgical and prosthetic part in mind is the key of success. Often practitioners tend to create a treatment plan overlooking the basic principles of prosthetic part. This present review has discussed various prosthetic consideration of implant-supported prosthesis. A step-by-step detailed prosthetic option with their indications has been discussed to help all dental implant practitioners in making of an optimal treatment plan for each case.

  4. Progress in surgical palliative treatment for malignant obstructive jaundice

    Directory of Open Access Journals (Sweden)

    LIANG Zhang

    2013-06-01

    Full Text Available Obstructive jaundice, also known as surgical jaundice, is divided into benign and malignant types. Most of the patients newly diagnosed with malignant obstructive jaundice have lost the opportunity of receiving radical surgery due to its insidious onset, so surgical palliative treatment is very important for patients with advanced malignant obstructive jaundice. This paper elaborates on various current modalities of surgical palliative treatment for malignant obstructive jaundice. Appropriate modality of surgical palliative treatment is of great significance for patients with advanced malignant obstructive jaundice.

  5. Surgical approach to end-stage heart failure.

    Science.gov (United States)

    Klotz, Stefan; Scheld, Hans H

    2011-02-01

    End-stage heart failure is a challenging disease with growing incidence. With decreasing heart transplant rates worldwide organ preserving therapies become, again, of interest. The purpose of the present review is to examine the potential challenges of surgical therapies in patients with end-stage heart failure. The gold-standard for end-stage heart failure is and will be cardiac transplantation. However, due to organ shortage this therapy is limited to a few patients. Therefore implantation of ventricular assist devices (VADs) or long-term minimal-invasive partial support devices will increase. Improvements in device design with smaller devices, easier implantation techniques, and modified anticoagulation outcome and long-term success will likely improve. In addition, good quality of life as destination therapy is almost available. Organ conservation surgery (coronary artery bypass grafting and surgical ventricular restoration or surgical repair of mitral valve regurgitation) in end-stage heart failure patients could not prove the expected results. Transcatheter or minimal-invasive approaches of these therapies might become routine in the near future. Due to the overwhelming outcome rates, cardiac transplantation is the most established surgical therapy for end-stage heart failure. VAD therapy is increasing and minimized VADs might further open the market for destination therapy/permanent support.

  6. Surgical site infections in paediatric otolaryngology operative procedures.

    Science.gov (United States)

    Ifeacho, S N; Bajaj, Y; Jephson, C G; Albert, D M

    2012-07-01

    An assessment of the rate of surgical site infections associated with elective paediatric otolaryngology surgical procedures. Prospective data was collected for a 3-week period for all children undergoing surgery where either mucosa or skin was breached. The parents of the children were requested to complete a questionnaire at 30 days after the operation. Data was collected on 80 consecutive cases. The majority of cases were admitted on the day of the procedure. The procedures included adenotonsillectomy (24), grommets (12), cochlear implantation (6), bone-anchored hearing aid (2), submandibular gland excision (1), branchial sinus excision (1), cystic hygroma excision (3), nasal glioma excision (1), microlaryngobronchoscopy (13), tracheostomy (3) and other procedures (14). Nearly half the cases had more than one operation done at the same time. 26/80 (32.5%) patients had a temporary or permanent implant inserted at the time of operation (grommet, bone-anchored hearing aid, cochlear implant). 25/80 (31%) operative fields were classed as clean and 55/80 (68.7%) as clean contaminated operations. The duration of the operation varied from 6 min to 142 min. Hospital antibiotic protocol was adhered to in 69/80 (86.3%) cases but not in 11/80 cases. In our series, 3/80 (3.7%) patients had an infection in the postoperative period. Surgical site infections do occur at an appreciable rate in paediatric otolaryngology. With the potential for serious consequences, reduction in the risk of surgical site infections is important. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  7. Hearing Preservation after Cochlear Implantation: UNICAMP Outcomes

    Directory of Open Access Journals (Sweden)

    Guilherme Machado de Carvalho

    2013-01-01

    Full Text Available Background. Electric-acoustic stimulation (EAS is an excellent choice for people with residual hearing in low frequencies but not high frequencies and who derive insufficient benefit from hearing aids. For EAS to be effective, subjects' residual hearing must be preserved during cochlear implant (CI surgery. Methods. We implanted 6 subjects with a CI. We used a special surgical technique and an electrode designed to be atraumatic. Subjects' rates of residual hearing preservation were measured 3 times postoperatively, lastly after at least a year of implant experience. Subjects' aided speech perception was tested pre- and postoperatively with a sentence test in quiet. Subjects' subjective responses assessed after a year of EAS or CI experience. Results. 4 subjects had total or partial residual hearing preservation; 2 subjects had total residual hearing loss. All subjects' hearing and speech perception benefited from cochlear implantation. CI diminished or eliminated tinnitus in all 4 subjects who had it preoperatively. 5 subjects reported great satisfaction with their new device. Conclusions. When we have more experience with our surgical technique we are confident we will be able to report increased rates of residual hearing preservation. Hopefully, our study will raise the profile of EAS in Brazil and Latin/South America.

  8. [Influence of implants prepared by selective laser melting on early bone healing].

    Science.gov (United States)

    Liu, J Y; Chen, F; Ge, Y J; Wei, L; Pan, S X; Feng, H L

    2018-02-18

    To evaluate the influence of the rough surface of dental implants prepared by selective laser melting (SLM) on early bone healing around titanium implants. A total of sixteen titanium implants were involved in our research, of which eight implants were prepared by SLM (TIXOS Cylindrical, Leader-Novaxa, Milan, Italy; 3.3 mm×10 mm, internal hex) and the other eight were sandblasted, large-grit and acid-etched (SLA) implants (IMPLUS Cylindrical, Leader-Novaxa, Milan, Italy; 3.3 mm×10 mm, internal hex). All of the dental implants were inserted into the healed extraction sockets of the mandible of two adult male Beagle dogs. Half of the dental implants were designed to be healed beneath the mucosa and the other half were intended to be healed transgingivally and were immediately loaded by acrylic resin bridge restoration. Three types of tetracycline fluorescent labels, namely calcein blue, alizarin complexone and calcein, were administered into the veins of the Beagle dogs 2, 4, and 8 weeks after implant placement respectively for fluorescent evaluation of newly formed bone peri-implant. Both Beagle dogs were euthanized 12 weeks after implant insertion and the mandible block specimens containing the titanium implants and surrounding bone and soft tissue of each dog were carefully sectioned and dissected. A total of 16 hard tissue slices were obtained and stained with toluidine blue for microscopic examination and histomorphometric measurements. Histological observation was made for each slice under light microscope and laser scanning confocal microscope (LSCM). Comparison on new bone formation around titanium implants of each group was made and mineral apposition rate (MAR) was calculated for each group. Dental implants prepared by selective laser melting had achieved satisfying osseointegration to surrounding bone tissue after the healing period of 12 weeks. Newly formed bone tissue was observed creeping on the highly porous surface of the SLM implant and growing

  9. Versatility of Capsular Flaps in the Salvage of Exposed Breast Implants

    Directory of Open Access Journals (Sweden)

    Beniamino Brunetti, MD

    2015-03-01

    Full Text Available Summary: Breast implant exposure due to poor tissue coverage or previous irradiation represents a surgical challenge both in the reconstructive and aesthetic plastic surgery practice. In case of implant extrusion or incipient exposure, the commonly suggested strategies, such as targeted antibiotic therapy, drainage and lavage of the cavity, fistulectomy, and primary closure, may be ineffective leading the surgeon to an unwanted implant removal or to adopt more invasive flap coverage procedures. Breast implant capsule, in its physiological clinical behavior, can be considered as a new reliable source of tissue, which can be used in a wide range of clinical situations. In our hands, capsular flaps proved to be a versatile solution not only to treat breast contour deformities or inframammary fold malpositions but also to salvage exposed breast implants. In this scenario, the use of more invasive surgical techniques can be avoided or simply saved and delayed for future recurrences.(Plast Reconstr Surg Glob Open 2015;3:e340; doi:10.1097/GOX.0000000000000307; Published online 30 March 2015.

  10. Surgical complications following cochlear implantation in adults based on a proposed reporting consensus

    DEFF Research Database (Denmark)

    Jeppesen, Jonas; Faber, Christian Emil

    2013-01-01

    Abstract Conclusion: The rate of severe complications was low and cochlear implantation is a relatively safe procedure. Standardization is crucial when reporting on cochlear implant complications to ensure comparability between studies. A consensus on the reporting of complications proposed by a ...... occurred following one implantation (0.3%). Transient chorda tympani syndrome (30.8%), vertigo/dizziness (29.5%) and tinnitus (4.9%) were the most frequent minor complications....

  11. Role of interstitial implantation in gynecological cancer

    International Nuclear Information System (INIS)

    Nori, D.; Hilaris, B.S.

    1987-01-01

    Recurrent cancer at any site carries a gloomy prognosis. Cancer of the cervix that recurs after radical surgery or curative radiation therapy is a perplexing problem confronting both gynecological and radiation oncologists. In the authors' series, 45% of the patients survived disease-free at 1 year and 10% survived without disease at 5 years or longer following interstitial implantation for recurrent cervical cancer. The optimal utilization of this procedure seems to depend on the site of recurrence, the extent of the disease in the pelvis, and the status of para-aortic node involvement. This retrospective analysis enabled the authors to identify the prognostic factors. The most favorable group benefited by this technique were those who presented with either central recurrence or unilateral, localized pelvic side wall recurrent disease. The least morbidity was noticed in those patients with minimal surgical manipulations at the time of the interstitial implantation. The authors recommended that only a limited and essential surgical procedure should accompany interstitial implantation, since the associated morbidity and mortality is high and survival brief

  12. Peri-Implant Bone Loss and Peri-Implantitis: A Report of Three Cases and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Vanchit John

    2016-01-01

    Full Text Available Dental implant supported restorations have been added substantially to the clinical treatment options presented to patients. However, complications with these treatment options also arise due to improper patient selection and inadequate treatment planning combined with poor follow-up care. The complications related to the presence of inflammation include perimucositis, peri-implant bone loss, and peri-implantitis. Prevalence rates of these complications have been reported to be as high as 56%. Treatment options that have been reported include nonsurgical therapy, the use of locally delivered and systemically delivered antibiotics, and surgical protocols aimed at regenerating the lost bone and soft tissue around the implants. The aim of this article is to report on three cases and review some of the treatment options used in their management.

  13. Managing peri-implant bone loss: current understanding.

    Science.gov (United States)

    Aljateeli, Manar; Fu, Jia-Hui; Wang, Hom-Lay

    2012-05-01

    With the improved macro- and micro-designs, dental implants enjoy a high survival rate. However, peri-implant bone loss has recently emerged to be the focus of implant therapy. As such, researchers and clinicians are in need of finding predictable techniques to treat peri-implant bone loss and stop its progression. Literature search on the currently available treatment modalities was performed and a brief description of each modality was provided. Numerous techniques have been proposed and none has been shown to be superior and effective in managing peri-implant bone loss. This may be because of the complex of etiological factors acting on the implant-supported prosthesis hence the treatment approach has to be individually tailored. Due to the lack of high-level clinical evidence on the management of peri-implant bone loss, the authors, through a literature review, attempt to suggest a decision tree or guideline, based on sound periodontal surgical principles, to aid clinicians in managing peri-implantitis associated bone loss. © 2011 Wiley Periodicals, Inc.

  14. Hearing Preservation in Cochlear Implant Surgery

    Directory of Open Access Journals (Sweden)

    Priscila Carvalho Miranda

    2014-01-01

    Full Text Available In the past, it was thought that hearing loss patients with residual low-frequency hearing would not be good candidates for cochlear implantation since insertion was expected to induce inner ear trauma. Recent advances in electrode design and surgical techniques have made the preservation of residual low-frequency hearing achievable and desirable. The importance of preserving residual low-frequency hearing cannot be underestimated in light of the added benefit of hearing in noisy atmospheres and in music quality. The concept of electrical and acoustic stimulation involves electrically stimulating the nonfunctional, high-frequency region of the cochlea with a cochlear implant and applying a hearing aid in the low-frequency range. The principle of preserving low-frequency hearing by a “soft surgery” cochlear implantation could also be useful to the population of children who might profit from regenerative hair cell therapy in the future. Main aspects of low-frequency hearing preservation surgery are discussed in this review: its brief history, electrode design, principles and advantages of electric-acoustic stimulation, surgical technique, and further implications of this new treatment possibility for hearing impaired patients.

  15. Ahmed Glaucoma Valve Implantation in Vitrectomized Eyes

    Directory of Open Access Journals (Sweden)

    Nimet Yeşim Erçalık

    2018-01-01

    Full Text Available Purpose. To evaluate the outcomes of Ahmed glaucoma valve (AGV implantation in vitrectomized eyes. Materials and Methods. The medical records of 13 eyes that developed glaucoma due to emulsified silicon oil or neovascularization following pars plana vitrectomy and underwent AGV implantation were retrospectively reviewed. The main outcome measures were intraocular pressure (IOP, best-corrected visual acuity (BCVA, number of antiglaucoma medications, and postoperative complications. Surgical success was defined as last IOP ≤21 mmHg or ≥6 mmHg and without loss of light perception. Results. The mean follow-up duration was 11.7 ± 5.5 (range, 6–23 months. The mean IOP before the AGV implantation was 37.9 ± 6.7 mmHg with an average of 3.5 ± 1.2 drugs. At the final visit, the mean IOP was 15.9 ± 4.6 mmHg (p=0.001 and the mean number of glaucoma medications decreased to 2.3 ± 1.3 (p=0.021. At the last visit, 11 eyes (84.4% had stable or improved VA and one eye (7.7% had a final VA of no light perception. Surgical success was achieved in 11 of the 13 eyes (84.4%. Postoperative complications were bleb encapsulation (69.2%, early hypotony (38.5%, hyphema (23.1%, decompression retinopathy (23.1%, choroidal detachment (15.4%, intraocular hemorrhage (7.7%, and late endophthalmitis (7.7%. One eye (7.7% was enucleated because of late endophthalmitis. Conclusions. Despite complications necessitating medical and surgical interventions, vitrectomized eyes were effectively managed with AGV implantation.

  16. Ahmed Glaucoma Valve Implantation in Vitrectomized Eyes.

    Science.gov (United States)

    Erçalık, Nimet Yeşim; İmamoğlu, Serhat

    2018-01-01

    To evaluate the outcomes of Ahmed glaucoma valve (AGV) implantation in vitrectomized eyes. The medical records of 13 eyes that developed glaucoma due to emulsified silicon oil or neovascularization following pars plana vitrectomy and underwent AGV implantation were retrospectively reviewed. The main outcome measures were intraocular pressure (IOP), best-corrected visual acuity (BCVA), number of antiglaucoma medications, and postoperative complications. Surgical success was defined as last IOP ≤21 mmHg or ≥6 mmHg and without loss of light perception. The mean follow-up duration was 11.7 ± 5.5 (range, 6-23) months. The mean IOP before the AGV implantation was 37.9 ± 6.7 mmHg with an average of 3.5 ± 1.2 drugs. At the final visit, the mean IOP was 15.9 ± 4.6 mmHg ( p =0.001) and the mean number of glaucoma medications decreased to 2.3 ± 1.3 ( p =0.021). At the last visit, 11 eyes (84.4%) had stable or improved VA and one eye (7.7%) had a final VA of no light perception. Surgical success was achieved in 11 of the 13 eyes (84.4%). Postoperative complications were bleb encapsulation (69.2%), early hypotony (38.5%), hyphema (23.1%), decompression retinopathy (23.1%), choroidal detachment (15.4%), intraocular hemorrhage (7.7%), and late endophthalmitis (7.7%). One eye (7.7%) was enucleated because of late endophthalmitis. Despite complications necessitating medical and surgical interventions, vitrectomized eyes were effectively managed with AGV implantation.

  17. Analysis of corrosions-products in tissue samples near surgical implants by means of LAMMA (Laser Microprobe Mass Analyzer) and ICP-MS (Inductively Coupled Plasma Mass Spectrometer)

    International Nuclear Information System (INIS)

    Schlagenhaufen, C.

    1996-08-01

    In this work corrosion products of surgical implants in tissue samples were identified. For the characterization of the corrosion products the LAMMA 500 (Laser Microprobe Mass Analyzer) was used. Additional analysis were made with the ICP-MS (Inductively Coupled Plasma Mass Spectrometer) to determine the concentration of chromium, cobalt, nickel, and molybdenum in the tissues. In the first part several synthetic chromium- and molybdenum compounds were investigated with LAMMA. With the anionic mass spectra of the chromium-compounds it is possible to the oxidation state of chromium. The mass spectra of the synthetic compounds were used to identify, the compounds in the corrosion products. In the second part thin sections prepared from the tissue samples from the surrounding of the implants were analyzed. Several embedding and cutting methods were tested. Histological staining methods and LAMMA spectra were used to characterize the deposits in the tissue. Three different deposits were found in the tissue. In all tissues metal splinters from the implant were found. In most of the tissues iron-rich deposits were found, that were identified as iron-phosphate. As definitive corrosion products of the implant mixtures of chromium(III)phosphate, calcium molybdate, calcium phosphate and chromium(III) molybdate were identified. The ICP-MS results show in comparison to normal values, very high concentrations for chromium, nickel, cobalt and molybdenum. These results support the conclusions based on LAMMA results. The results of these investigations clearly indicate, that stainless steel implants, are not corrosion-resistant in the body. Relatively high amounts of the constituents, of the implant dissolved, and are deposited as solid compounds in the tissue next to the implant. (author)

  18. Graft infections after surgical aortic reconstructions

    NARCIS (Netherlands)

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open

  19. Ultrasonic implant site preparation using piezosurgery: a multicenter case series study analyzing 3,579 implants with a 1- to 3-year follow-up.

    Science.gov (United States)

    Vercellotti, Tomaso; Stacchi, Claudio; Russo, Crescenzo; Rebaudi, Alberto; Vincenzi, Giampaolo; Pratella, Umberto; Baldi, Domenico; Mozzati, Marco; Monagheddu, Chiara; Sentineri, Rosario; Cuneo, Tommaso; Di Alberti, Luca; Carossa, Stefano; Schierano, Gianmario

    2014-01-01

    This multicenter case series introduces an innovative ultrasonic implant site preparation (UISP) technique as an alternative to the use of traditional rotary instruments. A total of 3,579 implants were inserted in 1,885 subjects, and the sites were prepared using a specific ultrasonic device with a 1- to 3-year follow-up. No surgical complications related to the UISP protocol were reported for any of the implant sites. Seventy-eight implants (59 maxillary, 19 mandibular) failed within 5 months of insertion, for an overall osseointegration percentage of 97.82% (97.14% maxilla, 98.75% mandible). Three maxillary implants failed after 3 years of loading, with an overall implant survival rate of 97.74% (96.99% maxilla, 98.75% mandible).

  20. Treatment of peri-implant diseases: a review of the literature and protocol proposal.

    Science.gov (United States)

    Armas, Joshé; Culshaw, Shauna; Savarrio, Lee

    2013-01-01

    Over 100,000 implants were placed in the UK in 2010. As the numbers of patients with implant-retained prostheses increases, operators are encountering an increasing number of biological implant complications, most commonly peri-implant mucositis and peri-implantitis. The effective management of these complications is crucial to maintain patients' oral health. In particular, in contrast to common periodontal infections, some peri-implant infections may benefit from surgical intervention as a first line approach. This article reviews the literature on the treatment options for peri-implant mucositis and peri-implantitis and proposes a protocol for their treatment.

  1. The delivery of general paediatric surgery in Ireland: a survey of higher surgical trainees.

    LENUS (Irish Health Repository)

    Boyle, E

    2012-12-01

    The delivery of general paediatric surgery is changing in Ireland. Fewer paediatric surgical procedures are being performed by newly appointed consultant general surgeons, resulting in increased referrals to the specialist paediatric surgeons of uncomplicated general paediatric surgical problems. We surveyed current higher surgical trainees about their views on provision of paediatric surgical services.

  2. Teaching mandibular implant-Supported overdentures in dental schools in North America - a survey.

    Science.gov (United States)

    Ben-Gal, G; Ziv, Y; Weiss, E I; Zabrovsky, A

    2017-05-01

    Mandibular two-implant overdentures are considered the minimum standard of care for edentulous patients and provide an excellent performance, as well as satisfaction to the patients. Dental schools are required to promote the teaching of current treatment options in order to enable students to master state-of-the-art procedures. The purpose of this study was to examine how the theoretical and practical aspects of mandibular two-implant overdentures are taught in dental schools in North America. Data were collected via an online questionnaire that included questions regarding the theoretical and clinical courses, surgical procedure and imaging method. Of 75 schools, 36 responded to the survey. Almost all the schools teach the subject theoretically, but it is not mandatory for students to perform in most of the schools. Only a minority (23%) of the mandibular dentures made by students are implant-supported. Almost all of the schools (94%) use two implants to support overdentures, and Locator abutment is used almost exclusively. The prevalent imaging for the surgical procedure is CT scans, although 30% of the schools use panoramic radiograph. None of the schools loads the implants immediately after surgery. Some clear trends are apparent in the current survey: the use of two implants, no use of bar connectors and delayed loading of the implants. It is likely that graduates will not have sufficient clinical skills and will need continuing education to be familiar with the required procedures, both surgical and prosthetic. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Penile prosthesis implant: scientific advances and technological innovations over the last four decades.

    Science.gov (United States)

    Chung, Eric

    2017-02-01

    Despite introduction of oral phosphodiesterase type 5 inhibitors and intracavernosal vasoactive agents, penile prosthesis implant remains a relevant and desired option with sales of penile prostheses continue to stay high, as many men became refractory to medical therapy and/or seeking a more effective and permanent therapy. There are two types of penile prosthesis implants: inflatable and non-inflatable types, and the inflatable penile implants can be subdivided into single-, two- and three-piece devices. Non-inflatable penile prosthesis (non-IPP) may be referred to as semi-rigid rod or malleable prosthesis. IPP is considered a superior option to malleable prosthesis as it produces penile rigidity and flaccidity that closely replicates a normal penile erectile function. Since the introduction of IPP by Scott in 1973, surgical landscape for penile prosthesis implantation has changed dramatically. Advances in prosthesis design, device technologies and surgical techniques have made penile prosthesis implant a more natural, durable and reliable device. The following article reviews the scientific advances and technological innovation in modern penile prosthesis implants over the last four decades.

  4. Analysis of submerged implant towards mastication load using 3D finite element method (FEM

    Directory of Open Access Journals (Sweden)

    Widia Hafsyah Sumarlina Ritonga

    2016-11-01

    Full Text Available Introduction: The surgical procedure for implantation of a surgical implant comprising a stage for the implant design nonsubmerged and two stages for submerged. Submerged implant design often used in Faculty of Dentistry Universitas Padjadjaran because it is safer in achieving osseointegration. This study was conducted to evaluate the failure of dental implant based on location and the value of internal tensiones as well as supporting tissues when given mastication load by using the 3D Finite Element Method (FEM. Methods: This study used a photograph of the mandibular CBCT patient and CT Scan Micro one implant submerged. Radiograph image was then converted into a digital model of the 3D computerized finite element, inputted the material properties, pedestal, then simulated the occlusion load  as much as 87N and 29N of frictional Results: The maximum tension location on the implant was located on the  exact side of the contact area between the implant and alveolar crest. The maximum tension value was 193.31MPa on the implant body. The value was below the limit value of the ability of the titanium alloy to withstand fracture (860 MPa. Conclusion: The location of the maximum tension on the body of the implant was located on the exact contact area between the implant-abutment and alveolar crest. Under the mastication load, this implant design found no failure.

  5. Fluid Dynamics of a Novel Micro-Fistula Implant for the Surgical Treatment of Glaucoma.

    Science.gov (United States)

    Sheybani, Arsham; Reitsamer, Herbert; Ahmed, Iqbal Ike K

    2015-07-01

    The purpose of this study was to describe the fluidics of a novel non-valved glaucoma implant designed to prevent hypotony and compare the fluidics of this device with two commonly used non-valved glaucoma devices. The XEN 45 micro-fistula implant was designed to limit hypotony by virtue of its length and width according to the Hagen-Poiseuille equation. Flow testing was performed using a syringe pump and pressure transducer at multiple flow rates. The pressure differentials across the XEN implant, the Ex-Press implant, and 10 mm of silicone tubing from a Baerveldt implant at a physiologic flow rate (2.5 μL/min) were extrapolated. The XEN 45 achieved a steady-state pressure calculated at 7.56 mm Hg at 2.5 μL/min. At the same flow rate, the Ex-Press device and Baerveldt tubing reached steady-state pressures of 0.09 and 0.01 mm Hg, respectively. Under flow testing, the XEN micro-fistula implant was able to maintain backpressure above numerical hypotony levels without the use of complex valve systems. This is due to the XEN implant's design, derived from the principles that dictate Newtonian fluids.

  6. Simultaneous versus sequential bilateral cochlear implants in adults: Cost analysis in a US setting.

    Science.gov (United States)

    Trinidade, Aaron; Page, Joshua C; Kennett, Sarah W; Cox, Matthew D; Dornhoffer, John L

    2017-11-01

    From a purely surgical efficiency point of view, simultaneous cochlear implantation (SimCI) is more cost-effective than sequential cochlear implantation (SeqCI) when total direct costs are considered (implant and hospital costs). However, in a setting where only SeqCI is practiced and a proportion of initially unilaterally implanted patients do not progress to a second implant, this may not be the case, especially when audiological costs are factored in. We present a cost analysis of such a scenario as would occur in our institution. Retrospective review and cost analysis. Between 2005 and 2015, 370 patients fulfilled the audiological criteria for bilateral implantation. Of those, 267 (72.1%) underwent unilateral cochlear implantation only, 101 (27.3%) progressed to SeqCI, and two underwent SimCI. The total hospital, surgical, and implant costs, and initial implant stimulation series audiological costs between August 2015 and August 2016 (29 adult patients) were used in this analysis. The total hospital, surgical, and implant costs for this period was $2,731,360.42. Based on previous local trends, if a projected eight (27.3%) of these patients decide to progress to SeqCI, this will cost an additional $750,811.04, resulting in an overall total of $3,482,171.46 for these 29 patients. Had all 29 undergone SimCI, the total projected cost would have been $3,332,991.75, representing a total potential saving of $149,179.67 (4.3%). In institutions where only SeqCI is allowed in adults, overall patient management may cost marginally more than if SimCI were practiced. This will be of interest to CI programs and health insurance companies. 4. Laryngoscope, 127:2615-2618, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  7. Surgery without papilla incision: tunneling flap procedures in plastic periodontal and implant surgery.

    Science.gov (United States)

    Zuhr, Otto; Rebele, Stephan F; Cheung, Stefani L; Hürzeler, Markus B

    2018-06-01

    Diverse clinical advancements, together with some relevant technical innovations, have led to an increase in popularity of tunneling flap procedures in plastic periodontal and implant surgery in the recent past. This trend is further promoted by the fact that these techniques have lately been introduced to a considerably expanded range of indications. While originally described for the treatment of gingival recession-type defects, tunneling flap procedures may now be applied successfully in a variety of clinical situations in which augmentation of the soft tissues is indicated in the esthetic zone. Potential clinical scenarios include surgical thickening of thin buccal gingiva or peri-implant mucosa, alveolar ridge/socket preservation and implant second-stage surgery, as well as soft-tissue ridge augmentation or pontic site development. In this way, tunneling flap procedures developed from a technique, originally merely intended for surgical root coverage, into a capacious surgical conception in plastic periodontal and implant surgery. The purpose of this article is to provide a comprehensive overview on tunneling flap procedures, to introduce the successive development of the approach along with underlying ideas on surgical wound healing and to present contemporary clinical scenarios in step-by-step photograph-illustrated sequences, which aim to provide clinicians with guidance to help them integrate tunneling flap procedures into their daily clinical routine. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Biofilm formation on surface characterized micro-implants for skeletal anchorage in orthodontics

    NARCIS (Netherlands)

    Chin, Yeen; Sandham, John; de Vries, Jacob; van der Mei, Henderina; Busscher, Hendrik

    Micro-implants are increasingly popular in clinical orthodontics to effect skeletal anchorage. However, biofilm formation on their surfaces and subsequent infection of peri-implant tissues can result in either exfoliation or surgical removal of these devices. The present study aimed to assess

  9. Surgical outcomes and nipple projection using the modified skate flap for nipple-areolar reconstruction in a series of 422 implant reconstructions.

    Science.gov (United States)

    Zhong, Toni; Antony, Anu; Cordeiro, Peter

    2009-05-01

    Numerous techniques have been used in an attempt to achieve long-term nipple projection following nipple-areolar reconstruction (NAR). A common setback, however, is the diminution of projection over time; this phenomenon is particularly evident following implant based breast reconstruction. The purpose of this report was thus to evaluate surgical outcomes and long-term nipple projection with the use of "modified skate flap" technique in exclusively implant based postmastectomy reconstructions. A retrospective review was performed for the period between 1993 and 2007. All consecutive patients with 2-staged tissue expander/implant reconstructions followed by NAR using the modified skate flap technique performed by the senior author (P.C.) were identified in a prospectively maintained breast reconstruction database. Only patients with a minimum of 1-year follow-up were included in the study. Patients with a history of irradiation to the breast were excluded from nipple projection assessment. Clinical outcome measurements included long-term nipple projection as well as incidence of complications from the NAR procedure using the modified skate flap technique. Over the 15-year study period, 475 patients underwent 2-staged tissue expander/implant reconstruction followed by NAR using the modified skate flap technique. Of these, there was a total of 292 patients with the minimum requirement of 1-year follow-up post NAR (61% follow-up rate). The total number of reconstructed nipple areolar complexes evaluated in this series was 422 (130 bilateral and 162 unilateral NAR). Forty patients (28 unilateral and 12 bilateral NAR) who received radiation to their breasts were excluded from nipple projection assessment. At a median follow-up of 44 months (range: 12-84 months), mean nipple projection was 2.5 mm (range: 1-4 mm). Minor complications occurred in 7.2% of the patients (n = 292). Skin graft donor site dehiscence was the most common complication (3.1%) followed by partial skin

  10. A new surgical method for penile girth enhancement

    OpenAIRE

    Li, Xiaoge; Tao, Ling; Cao, Chuan; Shi, Haishan; Li, Le; Chen, Liang; Li, Shirong

    2015-01-01

    Objective: We developed a new surgical model of penile girth enhancement in dog, with minimal damage, fewer complications, and high success rate, to enable the experimental investigation of penile implants. Methods: We obtained materials for penile girth enhancement by processing the pericardium and blood vessel wall collected from pigs. Incisions were made at the penile bulb for the implantation of the materials, and facilitate observation and data collection, based on the anatomical feature...

  11. Bone Response to Two Dental Implants with Different Sandblasted/Acid-Etched Implant Surfaces: A Histological and Histomorphometrical Study in Rabbits

    Directory of Open Access Journals (Sweden)

    Antonio Scarano

    2017-01-01

    Full Text Available Background. Scientific evidence in the field of implant dentistry of the past 20 years established that titanium rough surfaces have shown improved osseointegration rates. In a majority of dental implants, the surface microroughness was obtained by grit blasting and/or acid etching. The aim of the study was to evaluate in vivo two different highly hydrophilic surfaces at different experimental times. Methods. Calcium-modified (CA and SLActive surfaces were evaluated and a total of 18 implants for each type of surface were positioned into the rabbit articular femoral knee-joint in a split model experiment, and they were evaluated histologically and histomorphometrically at 15, 30, and 60 days of healing. Results. Bone-implant contact (BIC at the two-implant surfaces was significantly different in favor of the CA surface at 15 days (p=0.027, while SLActive displayed not significantly higher values at 30 (p=0.51 and 60 days (p=0.061. Conclusion. Both implant surfaces show an intimate interaction with newly formed bone.

  12. [Change of paradigms in the surgical treatment of complex thoracic aortic disease].

    Science.gov (United States)

    Herold, Ulf; Tsagakis, Konstantinos; Kamler, Markus; Massoudy, Parwis; Assenmacher, Eva; Eggebrecht, Holger; Buck, Thomas; Jakob, Heinz

    2006-08-01

    group. The experience gained with these devices revealed the limitations of the devices designed for pure retrograde aortic delivery. This required a complete redesign and new construction of the stent graft itself as well as the introducer system. In a preliminary series of 14 patients the required stent-graft properties were presented in detail and resulted in the first industrially manufactured standardized and CE-marked Hybrid stent graft (Essen 1 prosthesis, E-vita Open, Jotec), especially made for antegrade open stent grafting of the descending aorta. This device consists of a stent graft with an integrated Dacron vascular prosthesis, enabling for direct and continuous aortic arch replacement after stent grafting of the descending aorta. From 01/2005 to 03/2006, this hybrid prosthesis was implanted in 16 patients (one aneurysm and 15 aortic dissections). In all cases, the underlying pathology within the thoracic aspect of the aorta could be excluded in a one-stage approach. In case of aortic dissection, thrombosis of the false lumen was detectable by transesophageal echocardiography already at the end of surgery. Though long-term results using this new method are not yet available, the initial promising results postoperatively are encouraging toward true one-stage repair by combining classic aortic surgery with open antegrade stent grafting utilizing the newly designed hybrid prosthesis. While surgical trauma is markedly reduced, this treatment option can be offered to elderly patients as well.

  13. Cadaveric feasibility study of da Vinci Si-assisted cochlear implant with augmented visual navigation for otologic surgery.

    Science.gov (United States)

    Liu, Wen P; Azizian, Mahdi; Sorger, Jonathan; Taylor, Russell H; Reilly, Brian K; Cleary, Kevin; Preciado, Diego

    2014-03-01

    To our knowledge, this is the first reported cadaveric feasibility study of a master-slave-assisted cochlear implant procedure in the otolaryngology-head and neck surgery field using the da Vinci Si system (da Vinci Surgical System; Intuitive Surgical, Inc). We describe the surgical workflow adaptations using a minimally invasive system and image guidance integrating intraoperative cone beam computed tomography through augmented reality. To test the feasibility of da Vinci Si-assisted cochlear implant surgery with augmented reality, with visualization of critical structures and facilitation with precise cochleostomy for electrode insertion. Cadaveric case study of bilateral cochlear implant approaches conducted at Intuitive Surgical Inc, Sunnyvale, California. Bilateral cadaveric mastoidectomies, posterior tympanostomies, and cochleostomies were performed using the da Vinci Si system on a single adult human donor cadaveric specimen. Radiographic confirmation of successful cochleostomies, placement of a phantom cochlear implant wire, and visual confirmation of critical anatomic structures (facial nerve, cochlea, and round window) in augmented stereoendoscopy. With a surgical mean time of 160 minutes per side, complete bilateral cochlear implant procedures were successfully performed with no violation of critical structures, notably the facial nerve, chorda tympani, sigmoid sinus, dura, or ossicles. Augmented reality image overlay of the facial nerve, round window position, and basal turn of the cochlea was precise. Postoperative cone beam computed tomography scans confirmed successful placement of the phantom implant electrode array into the basal turn of the cochlea. To our knowledge, this is the first study in the otolaryngology-head and neck surgery literature examining the use of master-slave-assisted cochleostomy with augmented reality for cochlear implants using the da Vinci Si system. The described system for cochleostomy has the potential to improve the

  14. Regenerative surgical therapy for peri-implantitis using deproteinized bovine bone mineral with 10% collagen, enamel matrix derivative and Doxycycline-A prospective 3-year cohort study.

    Science.gov (United States)

    Mercado, Faustino; Hamlet, Stephen; Ivanovski, Saso

    2018-05-16

    There is limited evidence regarding the long-term efficacy of regenerative treatment for peri-implantitis. The aim of this study was to evaluate a combination therapy of deproteinized bovine bone mineral with 10% collagen (DBBMC), enamel matrix derivative (EMD) and Doxycycline in the regeneration of bone defects associated with peri-implantitis. Thirty patients diagnosed with peri-implantitis (BoP/suppuration, probing depth greater than 4 mm, minimum radiographic bone loss of 20%, at least 2 years in function) were enrolled in the study. Clinical measurements included probing depths, recession, radiographic bone fill, gingival inflammation and bleeding on probing/suppuration. Following surgical access and debridement, the implant surfaces were decontaminated with 24% EDTA for 2 min, and the bone defects were filled with a combined mixture of DBBMC, EMD and Doxycycline powder. The defects were covered with connective tissue grafts where necessary. Clinical measurements were recorded after 12, 24 and 36 months. The mean probing depth and bone loss at the initial visit was 8.9 mm (±1.9) and 6.92 mm (±1.26), respectively. Both mean probing depth and bone loss reduced significantly from baseline to 3.55 mm (±0.50) and 2.85 mm (±0.73) at 12 months, 3.50 (±0.50) and 2.62 mm (±0.80) at 24 months and 3.50 mm (±0.50) and 2.60 mm (±0.73) at 36 months. 56.6% of the implants were considered successfully treated (according to Successful Treatment Outcome Criterion: PD 10%, no BoP/suppuration, no recession >0.5 mm for anterior implants and >1.5 mm for posterior implants) after 36 months. Regenerative treatment of peri-implantitis using a combined mixture of DBBMC, EMD and Doxycycline achieved promising results. The benefits of this protocol incorporating EMD should be tested in randomized clinical trials. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Avaliação de um novo implante intra-orbitário: resultados preliminares Evaluation of a new intraorbital implant: preliminary results

    Directory of Open Access Journals (Sweden)

    Thierry Malet

    2003-01-01

    Full Text Available OBJETIVO: Apresentar novo tipo de implante orbitário, com formato original, o modo de utilização e os resultados clínicos preliminares. MÉTODOS: Os autores descrevem a técnica cirúrgica utilizada para a inserção do novo implante em 22 pacientes, como implante primário ou secundário. Os pacientes foram avaliados de forma prospectiva quanto aos seguintes aspectos: cosmético (grau de sulco suprapalpebral e enoftalmia, mobilidade, centragem e volume do implante. O tempo de seguimento variou de 3 a 15 meses (média 1 ano. RESULTADOS: Observou-se resultado cosmético satisfatório, sem casos de enoftalmia ou de sulco suprapalpebral importante, bem como boa mobilidade das próteses adaptadas sobre o novo implante. Não houve casos de infecção, migração ou extrusão do implante. CONCLUSÃO: Os resultados pós-operatórios com o novo implante são comparáveis aos implantes com pinos externos. Contudo um estudo multicêntrico, com maior tempo de controle pós-operatório é necessário, para avaliação mais acurada das complicações potenciais.PURPOSE: To describe a new orbital implant, with an original shape, the surgical technique adapted for its implantation and preliminary results. METHODS: The authors describe the surgical technique performed in 22 patients, either as primary or secondary implants. The patients were evaluated in a prospective way to cosmesis (degree of upper lid sulcus and enophthalmos, implant mobility, volume and centralization. Follow-up ranged from 3 to 15 months (average 1 year. RESULTS: A good cosmetic result without cases of severe upper lid sulcus or enophthalmos and a good prosthesis mobility were observed. There was no implant infection, migration or extrusion. CONCLUSIONS: We conclude that the clinical results with the new implant can be compared to the usual coupled ones, but a multicentric study, with longer follow-up is necessary, for a better evaluation of its potential complications.

  16. New orthopaedic implant management tool for computer-assisted planning, navigation, and simulation: from implant CAD files to a standardized XML-based implant database.

    Science.gov (United States)

    Sagbo, S; Blochaou, F; Langlotz, F; Vangenot, C; Nolte, L-P; Zheng, G

    2005-01-01

    Computer-Assisted Orthopaedic Surgery (CAOS) has made much progress over the last 10 years. Navigation systems have been recognized as important tools that help surgeons, and various such systems have been developed. A disadvantage of these systems is that they use non-standard formalisms and techniques. As a result, there are no standard concepts for implant and tool management or data formats to store information for use in 3D planning and navigation. We addressed these limitations and developed a practical and generic solution that offers benefits for surgeons, implant manufacturers, and CAS application developers. We developed a virtual implant database containing geometrical as well as calibration information for orthopedic implants and instruments, with a focus on trauma. This database has been successfully tested for various applications in the client/server mode. The implant information is not static, however, because manufacturers periodically revise their implants, resulting in the deletion of some implants and the introduction of new ones. Tracking these continuous changes and keeping CAS systems up to date is a tedious task if done manually. This leads to additional costs for system development, and some errors are inevitably generated due to the huge amount of information that has to be processed. To ease management with respect to implant life cycle, we developed a tool to assist end-users (surgeons, hospitals, CAS system providers, and implant manufacturers) in managing their implants. Our system can be used for pre-operative planning and intra-operative navigation, and also for any surgical simulation involving orthopedic implants. Currently, this tool allows addition of new implants, modification of existing ones, deletion of obsolete implants, export of a given implant, and also creation of backups. Our implant management system has been successfully tested in the laboratory with very promising results. It makes it possible to fill the current gap

  17. Soft tissue wound healing around teeth and dental implants.

    Science.gov (United States)

    Sculean, Anton; Gruber, Reinhard; Bosshardt, Dieter D

    2014-04-01

    To provide an overview on the biology and soft tissue wound healing around teeth and dental implants. This narrative review focuses on cell biology and histology of soft tissue wounds around natural teeth and dental implants. The available data indicate that: (a) Oral wounds follow a similar pattern. (b) The tissue specificities of the gingival, alveolar and palatal mucosa appear to be innately and not necessarily functionally determined. (c) The granulation tissue originating from the periodontal ligament or from connective tissue originally covered by keratinized epithelium has the potential to induce keratinization. However, it also appears that deep palatal connective tissue may not have the same potential to induce keratinization as the palatal connective tissue originating from an immediately subepithelial area. (d) Epithelial healing following non-surgical and surgical periodontal therapy appears to be completed after a period of 7–14 days. Structural integrity of a maturing wound between a denuded root surface and a soft tissue flap is achieved at approximately 14-days post-surgery. (e) The formation of the biological width and maturation of the barrier function around transmucosal implants requires 6–8 weeks of healing. (f) The established peri-implant soft connective tissue resembles a scar tissue in composition, fibre orientation, and vasculature. (g) The peri-implant junctional epithelium may reach a greater final length under certain conditions such as implants placed into fresh extraction sockets versus conventional implant procedures in healed sites. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Měření primární stability dentálního implantátu a její ovlivnění designem implantátu

    OpenAIRE

    Dzan, Ladislav

    2017-01-01

    1 SUMMARY Measurement of primary stability of the dental implant and the influence of the implant de- sign Primary stability is the lack of mobility in the bone after an implant insertion and it is conditioned by the quality and quantity of the bone, the surgical technique and the skill of the surgeon. Another element is the micro-design and especially macro-design of the implant, whose influence on the primary stability has not been given sufficient scientific attention. The objective of thi...

  19. Performance of Surgical Risk Scores to Predict Mortality after Transcatheter Aortic Valve Implantation

    Directory of Open Access Journals (Sweden)

    Leonardo Sinnott Silva

    2015-01-01

    Full Text Available Abstract Background: Predicting mortality in patients undergoing transcatheter aortic valve implantation (TAVI remains a challenge. Objectives: To evaluate the performance of 5 risk scores for cardiac surgery in predicting the 30-day mortality among patients of the Brazilian Registry of TAVI. Methods: The Brazilian Multicenter Registry prospectively enrolled 418 patients undergoing TAVI in 18 centers between 2008 and 2013. The 30-day mortality risk was calculated using the following surgical scores: the logistic EuroSCORE I (ESI, EuroSCORE II (ESII, Society of Thoracic Surgeons (STS score, Ambler score (AS and Guaragna score (GS. The performance of the risk scores was evaluated in terms of their calibration (Hosmer–Lemeshow test and discrimination [area under the receiver–operating characteristic curve (AUC]. Results: The mean age was 81.5 ± 7.7 years. The CoreValve (Medtronic was used in 86.1% of the cohort, and the transfemoral approach was used in 96.2%. The observed 30-day mortality was 9.1%. The 30-day mortality predicted by the scores was as follows: ESI, 20.2 ± 13.8%; ESII, 6.5 ± 13.8%; STS score, 14.7 ± 4.4%; AS, 7.0 ± 3.8%; GS, 17.3 ± 10.8%. Using AUC, none of the tested scores could accurately predict the 30-day mortality. AUC for the scores was as follows: 0.58 [95% confidence interval (CI: 0.49 to 0.68, p = 0.09] for ESI; 0.54 (95% CI: 0.44 to 0.64, p = 0.42 for ESII; 0.57 (95% CI: 0.47 to 0.67, p = 0.16 for AS; 0.48 (95% IC: 0.38 to 0.57, p = 0.68 for STS score; and 0.52 (95% CI: 0.42 to 0.62, p = 0.64 for GS. The Hosmer–Lemeshow test indicated acceptable calibration for all scores (p > 0.05. Conclusions: In this real world Brazilian registry, the surgical risk scores were inaccurate in predicting mortality after TAVI. Risk models specifically developed for TAVI are required.

  20. Trauma to an implant-supported crown that was saved by the fixation screw : A case report

    NARCIS (Netherlands)

    den Hartog, Laurens; Meijer, Henny J. A.; Stellingsma, Kees; Santing, Hendrik J.; Raghoebar, Gerry M.

    A traumatic impact to an implant-supported crown might damage the implant, restoration and peri-implant tissues. Ideally, only a small prosthetic retreatment is needed for restoration, as complicated prosthetic retreatments or surgical retreatments in particular, could be very inconvenient for the

  1. Vertical Root Fracture: Preservation of the Alveolar Ridge Using Immediate Implants

    Directory of Open Access Journals (Sweden)

    Edmar de Oliveira Oya

    2014-01-01

    Full Text Available Teeth with vertical root fracture (VRF have complete or incomplete fractures that begin in the root and extend toward the occlusal surface. The most frequent causes of VRF originate from physical trauma, occlusal prematurity, inadequate endodontic treatment, and iatrogenic causes. Diagnose is difficult and delay can cause stomatognathic system problem. The purpose of this case report was to evaluate immediate implant placement after extraction of teeth with vertical root fracture. For the 1st case, the VRF in 1st left lower molar was confirmed during surgical flap and at the same time, the tooth was removed and immediate implant was placed. For the 2nd case, the VRF 1st left lower molar was confirmed during endodontic access and at the same appointment, the tooth was removed and the immediate implant is placed. Several studies have shown that immediate implants have similar success rates when compared with late implants. Consider that this approach is a safe procedure with favorable prognosis. In cases of VRF, the main factor to be considered is the presence of adequate bone support and immediate implants can preserve the vertical bone height, adding the fact that good patient compliance reduces the number of surgical interventions and promotes the functionality of stomatognathic system.

  2. Surgical data processing for smart intraoperative assistance systems

    Directory of Open Access Journals (Sweden)

    Stauder Ralf

    2017-09-01

    Full Text Available Different components of the newly defined field of surgical data science have been under research at our groups for more than a decade now. In this paper, we describe our sensor-driven approaches to workflow recognition without the need for explicit models, and our current aim is to apply this knowledge to enable context-aware surgical assistance systems, such as a unified surgical display and robotic assistance systems. The methods we evaluated over time include dynamic time warping, hidden Markov models, random forests, and recently deep neural networks, specifically convolutional neural networks.

  3. Biomechanical rationale and evaluation of an implant system for rib fracture fixation

    OpenAIRE

    Bottlang, M.; Walleser, S.; Noll, M.; Honold, S.; Madey, S. M.; Fitzpatrick, D.; Long, W. B.

    2010-01-01

    Background Biomechanical research directed at developing customized implant solutions for rib fracture fixation is essential to reduce the complexity and to increase the reliability of rib osteosynthesis. Without a simple and reliable implant solution, surgical stabilization of rib fractures will remain underutilized despite proven benefits for select indications. This article summarizes the research, development, and testing of a specialized and comprehensive implant solution for rib fractur...

  4. Development of implant/interconnected porous hydroxyapatite complex as new concept graft material.

    Directory of Open Access Journals (Sweden)

    Kazuya Doi

    Full Text Available BACKGROUND: Dental implant has been successfully used to replace missing teeth. However, in some clinical situations, implant placement may be difficult because of a large bone defect. We designed novel complex biomaterial to simultaneously restore bone and place implant. This complex was incorporated implant into interconnected porous calcium hydroxyapatite (IP-CHA. We then tested this Implant/IP-CHA complex and evaluated its effect on subsequent bone regeneration and implant stability in vivo. METHODOLOGY/PRINCIPAL FINDINGS: A cylinder-type IP-CHA was used in this study. After forming inside of the cylinder, an implant was placed inside to fabricate the Implant/IP-CHA complex. This complex was then placed into the prepared bone socket in the femur of four beagle-Labrador hybrid dogs. As a control, implants were placed directly into the femur without any bone substrate. Bone sockets were allowed to heal for 2, 3 and 6 months and implant stability quotients (ISQ were measured. Finally, tissue blocks containing the Implant/IP-CHA complexes were harvested. Specimens were processed for histology and stained with toluidine blue and bone implant contact (BIC was measured. The ISQs of complex groups was 77.8±2.9 in the 6-month, 72.0±5.7 in the 3-month and 47.4±11.0 in the 2-month. There was no significant difference between the 3- or 6-month complex groups and implant control groups. In the 2-month group, connective tissue, including capillary angiogenesis, was predominant around the implants, although newly formed bone could also be observed. While, in the 3 and 6-month groups, newly formed bone could be seen in contact to most of the implant surface. The BICs of complex groups was 2.18±3.77 in the 2-month, 44.03±29.58 in the 3-month, and 51.23±8.25 in the 6-month. Significant difference was detected between the 2 and 6-month. CONCLUSIONS/SIGNIFICANCE: Within the results of this study, the IP-CHA/implant complex might be able to achieve both

  5. Interventions for replacing missing teeth: treatment of peri-implantitis.

    Science.gov (United States)

    Esposito, Marco; Grusovin, Maria Gabriella; Worthington, Helen V

    2012-01-18

    One of the key factors for the long-term success of oral implants is the maintenance of healthy tissues around them. Bacterial plaque accumulation induces inflammatory changes in the soft tissues surrounding oral implants and it may lead to their progressive destruction (peri-implantitis) and ultimately to implant failure. Different treatment strategies for peri-implantitis have been suggested, however it is unclear which are the most effective. To identify the most effective interventions for treating peri-implantitis around osseointegrated dental implants. We searched the Cochrane Oral Health Group's Trials Register, CENTRAL, MEDLINE and EMBASE. Handsearching included several dental journals. We checked the bibliographies of the identified randomised controlled trials (RCTs) and relevant review articles for studies outside the handsearched journals. We wrote to authors of all identified RCTs, to more than 55 dental implant manufacturers and an Internet discussion group to find unpublished or ongoing RCTs. No language restrictions were applied. The last electronic search was conducted on 9 June 2011. All RCTs comparing agents or interventions for treating peri-implantitis around dental implants. Screening of eligible studies, assessment of the methodological quality of the trials and data extraction were conducted in duplicate and independently by two review authors. We contacted the authors for missing information. Results were expressed as random-effects models using mean differences for continuous outcomes and risk ratios for dichotomous outcomes with 95% confidence intervals (CI). Heterogeneity was to be investigated including both clinical and methodological factors. Fifteen eligible trials were identified, but six were excluded. The following interventions were compared in the nine included studies: different non-surgical interventions (five trials); adjunctive treatments to non-surgical interventions (one trial); different surgical interventions (two trials

  6. The osteoinductive effect of chitosan-collagen composites around pure titanium implant surfaces in rats.

    Science.gov (United States)

    Kung, S; Devlin, H; Fu, E; Ho, K-Y; Liang, S-Y; Hsieh, Y-D

    2011-02-01

    The enhancing effects of chitosan on activation of platelets and differentiation of osteoprogenitor cells have been demonstrated in vitro. The purpose of this study was to evaluate the in vivo osteoinductive effect of chitosan-collagen composites around pure titanium implant surfaces. Chitosan-collagen composites containing chitosan of different molecular weights (450 and 750 kDa) were wrapped onto titanium implants and embedded into the subcutaneous area on the back of 15 Sprague-Dawley rats. The control consisted of implants wrapped with plain collagen type I membranes. Implants and surrounding tissues were retrieved 6 wks after surgery and identified by Alizarin red and Alcian blue whole mount staining. The newly formed structures in the test groups were further analyzed by Toluidine blue and Masson-Goldner trichrome staining, and immunohistochemical staining with osteopontin and alkaline phosphotase. The bone formation parameters of the new bone in the two test groups were measured and compared. New bone formed ectopically in both chitosan-collagen groups, whereas no bone induction occurred in the negative control group. These newly formed bone-like structures were further confirmed by immunohistochemical staining. Comparison of bone parameters of the newly induced bone revealed no statistically significant differences between the 450 and 750 kDa chitosan-collagen groups. Our results demonstrated that chitosan-collagen composites might induce in vivo new bone formation around pure titanium implant surfaces. Different molecular weights of chitosan did not show significantly different effects on the osteoinductive potential of the test materials. © 2010 John Wiley & Sons A/S.

  7. Iso-surface volume rendering for implant surgery

    NARCIS (Netherlands)

    van Foreest-Timp, Sheila; Lemke, H.U.; Inamura, K.; Doi, K.; Vannier, M.W.; Farman, A.G.

    2001-01-01

    Many clinical situations ask for the simultaneous visualization of anatomical surfaces and synthetic meshes. Common examples include hip replacement surgery, intra-operative visualization of surgical instruments or probes, visualization of planning information, or implant surgery. To be useful for

  8. Do Prolonged Prophylactic Antibiotics Reduce the Incidence of Surgical-Site Infections in Immediate Prosthetic Breast Reconstruction?

    Science.gov (United States)

    Wang, Frederick; Chin, Robin; Piper, Merisa; Esserman, Laura; Sbitany, Hani

    2016-12-01

    Approximately 50,000 women in the United States undergo mastectomy and immediate prosthetic breast reconstruction annually, and most receive postoperative prophylactic antibiotics. The effect of these antibiotics on the risk of surgical-site infections remains unclear. The authors searched the Medline, Embase, and Cochrane Library databases for studies that compared less than 24 hours and greater than 24 hours of antibiotics following immediate prosthetic breast reconstruction. Primary outcomes were surgical-site infections and implant loss. Conservative random effects models were used to obtain pooled relative risk estimates. The authors identified 927 studies, but only four cohort studies and one randomized controlled trial met their inclusion criteria. Unadjusted incidences of surgical-site infections were 14 percent with more than 24 hours of antibiotics, 19 percent with less than 24 hours of antibiotics, and 16 percent overall. Unadjusted incidences of implant loss were 8 percent with more than 24 hours of antibiotics, 10 percent with less than 24 hours of antibiotics, and 9 percent overall. The pooled relative risk of implant loss was 1.17 (95 percent CI, 0.39 to 3.6) with less than 24 hours of antibiotics, which was not statistically significant. Prolonged antibiotic use did not have a statistically significant effect on reducing surgical-site infections or implant loss. There was significant heterogeneity between studies, and prolonged antibiotics may have increased the risk of implant loss in the randomized controlled trial. Definitive evidence may only be obtained with data from more prospective randomized controlled trials.

  9. A comparative study of zirconium and titanium implants in rat: osseointegration and bone material quality.

    Science.gov (United States)

    Hoerth, Rebecca M; Katunar, María R; Gomez Sanchez, Andrea; Orellano, Juan C; Ceré, Silvia M; Wagermaier, Wolfgang; Ballarre, Josefina

    2014-02-01

    Permanent metal implants are widely used in human medical treatments and orthopedics, for example as hip joint replacements. They are commonly made of titanium alloys and beyond the optimization of this established material, it is also essential to explore alternative implant materials in view of improved osseointegration. The aim of our study was to characterize the implant performance of zirconium in comparison to titanium implants. Zirconium implants have been characterized in a previous study concerning material properties and surface characteristics in vitro, such as oxide layer thickness and surface roughness. In the present study, we compare bone material quality around zirconium and titanium implants in terms of osseointegration and therefore characterized bone material properties in a rat model using a multi-method approach. We used light and electron microscopy, micro Raman spectroscopy, micro X-ray fluorescence and X-ray scattering techniques to investigate the osseointegration in terms of compositional and structural properties of the newly formed bone. Regarding the mineralization level, the mineral composition, and the alignment and order of the mineral particles, our results show that the maturity of the newly formed bone after 8 weeks of implantation is already very high. In conclusion, the bone material quality obtained for zirconium implants is at least as good as for titanium. It seems that the zirconium implants can be a good candidate for using as permanent metal prosthesis for orthopedic treatments.

  10. The Use of a Polyetheretherketone (PEEK) Implant to Reconstruct the Midface Region.

    Science.gov (United States)

    Hussain, Rumana N; Clark, Martin; Berry-Brincat, Antonella

    A good functional and cosmetic result after midfacial reconstructive surgical procedures is of paramount importance. We describe the use of a Polyetheretherketone (PEEK) implant to reconstruct the midface area, after extensive mutilating surgery due to an infiltrative skin tumor. A 67-year-old male patient underwent multiple and extensive surgeries to the left cheek and lower lid because of a highly aggressive metatypical basal cell carcinoma. Complete resection of the recurrent tumor resulted in a cosmetically evident absent cheek contour and facial deformity. The PEEK implant was used to restore the bony cheek contour, with good aesthetic outcome and restoration of the facial symmetry. Preoperative planning with 3-dimensional CT scans allow for customization of the implant. PEEK implants have been scantily described in the periorbital region. The material has a very low reported morbidity and also has the advantage of improving intraoperative predictability and reducing surgical time in complex reconstructive procedures.

  11. Complications in cochlear implantation at the Clinical Center of Vojvodina

    Directory of Open Access Journals (Sweden)

    Dankuc Dragan

    2015-01-01

    Full Text Available Introduction. The first modern cochlear implantation in Serbia was performed on November 26, 2002 at the Center for Cochlear Implantation of the Clinic for Ear, Nose and Throat Diseases, Clinical Center of Vojvodina. Objective. The aim of the paper is the analysis of intraoperative and postoperative complications. Major complications include those resulting in the necessity for revision surgery, explantation, reimplantation, severe disease or even lethal outcomes. Minor complications resolve spontaneously or can be managed by conservative therapy and do not require any prolonged hospitalization of the patient. Methods. In the 2002-2013 period, 99 patients underwent surgical procedures and 100 cochlear implants were placed. Both intraoperative and postoperative complications were analyzed in the investigated patient population. Results. The analysis encompassed 99 patients, the youngest and the oldest ones being one year old and 61 years old, respectively. The complications were noticed in 11 patients, i.e. in 10.5% of 105 surgical procedures. The majority of procedures (89.5% were not accompanied by any post-surgical complications. Unsuccessful implantation in a single-step procedure (4.04% and transient facial nerve paralysis can be considered most frequent among our patients, whereas cochlear ossification (1.01% and transient ataxia (2.02% occurred rarely. Stimulation of the facial nerve (1.01%, intraoperative perilymph liquid gusher (1.01%, device failure and late infections (1.01% were recorded extremely rarely. Conclusion. Complications such as electrode extrusion, skin necrosis over the implant or meningitis, which is considered the most severe postoperative complication, have not been recorded at our Center since the very beginning. Absence of postoperative meningitis in patients treated at the Center can be attributed to timely pneumococcal vaccination of children.

  12. Quality standards for bone conduction implants.

    Science.gov (United States)

    Gavilan, Javier; Adunka, Oliver; Agrawal, Sumit; Atlas, Marcus; Baumgartner, Wolf-Dieter; Brill, Stefan; Bruce, Iain; Buchman, Craig; Caversaccio, Marco; De Bodt, Marc T; Dillon, Meg; Godey, Benoit; Green, Kevin; Gstoettner, Wolfgang; Hagen, Rudolf; Hagr, Abdulrahman; Han, Demin; Kameswaran, Mohan; Karltorp, Eva; Kompis, Martin; Kuzovkov, Vlad; Lassaletta, Luis; Li, Yongxin; Lorens, Artur; Martin, Jane; Manoj, Manikoth; Mertens, Griet; Mlynski, Robert; Mueller, Joachim; O'Driscoll, Martin; Parnes, Lorne; Pulibalathingal, Sasidharan; Radeloff, Andreas; Raine, Christopher H; Rajan, Gunesh; Rajeswaran, Ranjith; Schmutzhard, Joachim; Skarzynski, Henryk; Skarzynski, Piotr; Sprinzl, Georg; Staecker, Hinrich; Stephan, Kurt; Sugarova, Serafima; Tavora, Dayse; Usami, Shin-Ichi; Yanov, Yuri; Zernotti, Mario; Zorowka, Patrick; de Heyning, Paul Van

    2015-01-01

    Bone conduction implants are useful in patients with conductive and mixed hearing loss for whom conventional surgery or hearing aids are no longer an option. They may also be used in patients affected by single-sided deafness. To establish a consensus on the quality standards required for centers willing to create a bone conduction implant program. To ensure a consistently high level of service and to provide patients with the best possible solution the members of the HEARRING network have established a set of quality standards for bone conduction implants. These standards constitute a realistic minimum attainable by all implant clinics and should be employed alongside current best practice guidelines. Fifteen items are thoroughly analyzed. They include team structure, accommodation and clinical facilities, selection criteria, evaluation process, complete preoperative and surgical information, postoperative fitting and assessment, follow-up, device failure, clinical management, transfer of care and patient complaints.

  13. Surgical and procedural skills training at medical school - a national review.

    Science.gov (United States)

    Davis, Christopher R; Toll, Edward C; Bates, Anthony S; Cole, Matthew D; Smith, Frank C T

    2014-01-01

    This national study quantifies procedural and surgical skills training at medical schools in the United Kingdom (UK), a stipulated requirement of all graduates by the General Medical Council (GMC). A questionnaire recorded basic procedural and surgical skills training provided by medical schools and surgical societies in the UK. Skills were extracted from (1) GMC Tomorrows Doctors and (2) The Royal College of Surgeons Intercollegiate Basic Surgical Skills (BSS) course. Data from medical school curricula and extra-curricular student surgical societies were compared against the national GMC guidelines and BSS course content. Data were analysed using Mann-Whitney U tests. Representatives from 23 medical schools completed the survey (71.9% response). Thirty one skills extracted from the BSS course were split into 5 categories, with skills content cross referenced against GMC documentation. Training of surgical skills by medical schools was as follows: Gowning and gloving (72.8%), handling instruments (29.4%), knot tying (17.4%), suturing (24.7%), other surgical techniques (4.3%). Surgical societies provided significantly more training of knot tying (64.4%, P = 0.0013) and suturing (64.5%, P = 0.0325) than medical schools. Medical schools provide minimal basic surgical skills training, partially supplemented by extracurricular student surgical societies. Our findings suggest senior medical students do not possess simple surgical and procedural skills. Newly qualified doctors are at risk of being unable to safely perform practical procedures, contradicting GMC Guidelines. We propose a National Undergraduate Curriculum in Surgery and Surgical Skills to equip newly qualified doctors with basic procedural skills to maximise patient safety. Copyright © 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  14. Surgical revascularization induces angiogenesis in orthotopic bone allograft

    NARCIS (Netherlands)

    Willems, Wouter F.; Kremer, Thomas; Friedrich, Patricia; Bishop, Allen T.

    2012-01-01

    Remodeling of structural bone allografts relies on adequate revascularization, which can theoretically be induced by surgical revascularization. We developed a new orthotopic animal model to determine the technical feasibility of axial arteriovenous bundle implantation and resultant angiogenesis. We

  15. Effect of a preoperative decontamination protocol on surgical site infections in patients undergoing elective orthopedic surgery with hardware implantation.

    Science.gov (United States)

    Bebko, Serge P; Green, David M; Awad, Samir S

    2015-05-01

    Surgical site infections (SSIs), commonly caused by methicillin-resistant Staphylococcus aureus (MRSA), are associated with significant morbidity and mortality, specifically when hardware is implanted in the patient. Previously, we have demonstrated that a preoperative decontamination protocol using chlorhexidine gluconate washcloths and intranasal antiseptic ointment is effective in eradicating MRSA in the nose and on the skin of patients. To examine the effect of a decontamination protocol on SSIs in patients undergoing elective orthopedic surgery with hardware implantation. A prospective database of patients undergoing elective orthopedic surgery with hardware implantation at the Michael E. DeBakey Veterans Affairs Medical Center in Houston, Texas, was analyzed from October 1, 2012, to December 31, 2013. Cohort groups before and after the intervention were compared. Starting in May 2013, during their preoperative visit, all of the patients watched an educational video about MRSA decontamination and were given chlorhexidine washcloths and oral rinse and nasal povidone-iodine solution to be used the night before and the morning of scheduled surgery. Thirty-day SSI rates were collected according to the definitions of the Centers for Disease Control and Prevention National Nosocomial Infections Surveillance. Data on demographics, comorbidities such as chronic obstructive pulmonary disease and coronary artery disease, tobacco use, alcohol use, and body mass index were also collected. Univariate analysis was performed between the 2 groups of patients. Multivariate analysis was used to identify independent predictors of SSI. A total of 709 patients were analyzed (344 controls and 365 patients who were decolonized). Both groups were well matched with no significant differences in age, body mass index, sex, or comorbidities. All of the patients (100%) completed the MRSA decontamination protocol. The SSI rate in the intervention group was significantly lower (1.1%; 4 of

  16. Immediate loading with single-piece implant following extraction

    Directory of Open Access Journals (Sweden)

    Hemlata Dwivedi

    2017-01-01

    Full Text Available Although dental implantology had evolved over a number of years, many dental surgeons are unaware of the concept of immediate loading with the use of one-piece implant that began in the early 1960s. The goal of successful prosthodontics rehabilitation is to provide function, esthetics, and comfort to the patient. The aim of this literature is to provide an overview of one-piece implant, with its advantages and disadvantages over conventional two-piece implant. Immediate prosthetic of a one-piece system allows for a better tissue healing and better adhesion of gingival mucosa to form a collar which is healthy and adherent to the implant, avoiding a second surgical procedure, and also includes a very important aspect esthetics. This article describes a case report of immediate loading with single-piece implant following extraction.

  17. Surgical simulation in orthopaedic skills training.

    Science.gov (United States)

    Atesok, Kivanc; Mabrey, Jay D; Jazrawi, Laith M; Egol, Kenneth A

    2012-07-01

    Mastering rapidly evolving orthopaedic surgical techniques requires a lengthy period of training. Current work-hour restrictions and cost pressures force trainees to face the challenge of acquiring more complex surgical skills in a shorter amount of time. As a result, alternative methods to improve the surgical skills of orthopaedic trainees outside the operating room have been developed. These methods include hands-on training in a laboratory setting using synthetic bones or cadaver models as well as software tools and computerized simulators that enable trainees to plan and simulate orthopaedic operations in a three-dimensional virtual environment. Laboratory-based training offers potential benefits in the development of basic surgical skills, such as using surgical tools and implants appropriately, achieving competency in procedures that have a steep learning curve, and assessing already acquired skills while minimizing concerns for patient safety, operating room time, and financial constraints. Current evidence supporting the educational advantages of surgical simulation in orthopaedic skills training is limited. Despite this, positive effects on the overall education of orthopaedic residents, and on maintaining the proficiency of practicing orthopaedic surgeons, are anticipated.

  18. Induced hemocompatibility and bone formation as biological scaffold for cell therapy implant

    Directory of Open Access Journals (Sweden)

    Keng-Liang Ou

    2016-06-01

    Full Text Available Although stem cells can become almost any type of specialized cell in the human body and may have the potential to generate replacement cells for tissues and organs, the transplantation of these cells are hindered by immune rejection and teratoma formation. However, scientists have found a promising solution for these problems-they have discovered the ability to isolate stem cells from a patient’s umbilical cord blood or bone marrow. Even more recently, small stem cells, such as spore-like stem cells, Blastomere-Like Stem Cells (BLSCs, and Very-Small Embryonic-Like stem cells (VSELs isolated directly from the peripheral blood have beeninvestigated as a novel approach to stem cell therapy as they can be isolated directly from the peripheral blood. A newly-discovered population of multipotent stem cells in this class has been dubbed StemBios (SB cells. The potential therapeutic uses of such stem cells have been explored in many ways, one of which includes dental remodeling and construction. Using adult stem cells, scientists have engineered and cultivated teeth in mice that may one day be used for human implantation.It follows that such regeneration may be possible, to a certain degree, in human patients as well. This idea leads to the present study on the effect of SB cell therapy on early osseointegrationof dental implants. Titanium (Ti dental implants have been proven to be a reliable and predictable treatment for restoration of edentulous regions. The osseointegration process can be described in two stages: primary stability (mechanical stability and secondary stability (biological stability. The mechanical stabilization of the implant reflects the interaction between the bone density and the features of the implant designs and can be determined after implant insertion. Alternatively,the biological stabilization of the implant is a physiologic healing process. It is couple to the biological interaction between the external surface of the

  19. Osseointegration of KrF laser hydroxylapatite films on Ti6A14V alloy by mini-pigs: loaded osseointegration of dental implants

    Science.gov (United States)

    Dostalova, Tatjana; Jelinek, Miroslav; Himmlova, Lucia; Grivas, Christos

    1999-05-01

    Aim of study was to evaluate osseointegration of the KrF laser hydroxyapatite coated titanium alloy Ti6Al4V dental implants. For deposition KrF excimer laser in stainless- steel deposition chamber was used. Thickness of HA films were round 1 μm . Mini-pigs were used in this investigation. Implants were placed vertically into the lower jaw. After 14 weeks unloaded osseointegration the metal ceramic crowns were inserted. the experimental animals were sacrificed (1 year post insertion). The vertical position of implants was controlled with a radiograph. Microscopical sections were cut and ground. Sections were viewed using microscope with CCD camera. 1 year osseointegration in lower jaw confirmed by all implants presence of newly formed bone around the all implants. Laser-deposited coating the layer of fibrous connective tissue was seen only seldom. In the control group (titamium implant without cover) the fibrous connective tissue was seen between implant and newly formed bone.

  20. The KineSpring® Knee Implant System: an implantable joint-unloading prosthesis for treatment of medial knee osteoarthritis

    Directory of Open Access Journals (Sweden)

    Clifford AG

    2013-05-01

    Full Text Available Anton G Clifford,1 Stefan M Gabriel,1 Mary O’Connell,1 David Lowe,1 Larry E Miller,2,3 Jon E Block31Moximed, Inc, Hayward, CA, USA; 2Miller Scientific Consulting, Inc, Arden, NC, USA; 3The Jon Block Group, San Francisco, CA, USAAbstract: Symptomatic medial compartment knee osteoarthritis (OA is the leading cause of musculoskeletal pain and disability in adults. Therapies intended to unload the medial knee compartment have yielded unsatisfactory results due to low patient compliance with conservative treatments and high complication rates with surgical options. There is no widely available joint-unloading treatment for medial knee OA that offers clinically important symptom alleviation, low complication risk, and high patient acceptance. The KineSpring® Knee Implant System (Moximed, Inc, Hayward, CA, USA is a first-of-its-kind, implantable, extra-articular, extra-capsular prosthesis intended to alleviate knee OA-related symptoms by reducing medial knee compartment loading while overcoming the limitations of traditional joint-unloading therapies. Preclinical and clinical studies have demonstrated excellent prosthesis durability, substantial reductions in medial compartment and total joint loads, and clinically important improvements in OA-related pain and function. The purpose of this report is to describe the KineSpring System, including implant characteristics, principles of operation, indications for use, patient selection criteria, surgical technique, postoperative care, preclinical testing, and clinical experience. The KineSpring System has potential to bridge the gap between ineffective conservative treatments and irreversible surgical interventions for medial compartment knee OA.Keywords: KineSpring, knee, medial, osteoarthritis, prosthesis

  1. Image calibration and registration in cone-beam computed tomogram for measuring the accuracy of computer-aided implant surgery

    Science.gov (United States)

    Lam, Walter Y. H.; Ngan, Henry Y. T.; Wat, Peter Y. P.; Luk, Henry W. K.; Goto, Tazuko K.; Pow, Edmond H. N.

    2015-02-01

    Medical radiography is the use of radiation to "see through" a human body without breaching its integrity (surface). With computed tomography (CT)/cone beam computed tomography (CBCT), three-dimensional (3D) imaging can be produced. These imagings not only facilitate disease diagnosis but also enable computer-aided surgical planning/navigation. In dentistry, the common method for transfer of the virtual surgical planning to the patient (reality) is the use of surgical stent either with a preloaded planning (static) like a channel or a real time surgical navigation (dynamic) after registration with fiducial markers (RF). This paper describes using the corner of a cube as a radiopaque fiducial marker on an acrylic (plastic) stent, this RF allows robust calibration and registration of Cartesian (x, y, z)- coordinates for linking up the patient (reality) and the imaging (virtuality) and hence the surgical planning can be transferred in either static or dynamic way. The accuracy of computer-aided implant surgery was measured with reference to coordinates. In our preliminary model surgery, a dental implant was planned virtually and placed with preloaded surgical guide. The deviation of the placed implant apex from the planning was x=+0.56mm [more right], y=- 0.05mm [deeper], z=-0.26mm [more lingual]) which was within clinically 2mm safety range. For comparison with the virtual planning, the physically placed implant was CT/CBCT scanned and errors may be introduced. The difference of the actual implant apex to the virtual apex was x=0.00mm, y=+0.21mm [shallower], z=-1.35mm [more lingual] and this should be brought in mind when interpret the results.

  2. Peri-implant evaluation of osseointegrated implants subjected to orthodontic forces: results after three years of functional loading

    Directory of Open Access Journals (Sweden)

    Bruna de Rezende Marins

    2016-04-01

    Full Text Available ABSTRACT Objective: The objective of this study was to clinically and radiographically assess the peri-implant conditions of implants used as orthodontic anchorage. Methods: Two groups were studied: 1 a test group in which osseointegrated implants were used as orthodontic anchorage, with the application of 200-cN force; and 2 a control group in which implants were not subjected to orthodontic force, but supported a screw-retained prosthesis. Clinical evaluations were performed three, six and nine months after prosthesis installation and 1- and 3-year follow-up examinations. Intraoral periapical radiographs were obtained 30 days after surgical implant placement, at the time of prosthesis installation, and one, two and three years thereafter. The results were compared by Kruskal-Wallis test. Results: There was no statistically significant difference in clinical probing depth (p = 0.1078 or mesial and distal crestal bone resorption (p = 0.1832 during the study period. After three years of follow-up, the mean probing depth was 2.21 mm for the control group and 2.39 mm for the test group. The implants of the control group showed a mean distance between the bone crest and implant shoulder of 2.39 mm, whereas the implants used as orthodontic anchorage showed a mean distance of 2.58 mm at the distal site. Conclusion: Results suggest that the use of stable intraoral orthodontic anchorage did not compromise the health of peri-implant tissues or the longevity of the implant.

  3. Mechanical behaviour of synthetic surgical meshes: finite element simulation of the herniated abdominal wall.

    Science.gov (United States)

    Hernández-Gascón, B; Peña, E; Melero, H; Pascual, G; Doblaré, M; Ginebra, M P; Bellón, J M; Calvo, B

    2011-11-01

    The material properties of meshes used in hernia surgery contribute to the overall mechanical behaviour of the repaired abdominal wall. The mechanical response of a surgical mesh has to be defined since the haphazard orientation of an anisotropic mesh can lead to inconsistent surgical outcomes. This study was designed to characterize the mechanical behaviour of three surgical meshes (Surgipro®, Optilene® and Infinit®) and to describe a mechanical constitutive law that accurately reproduces the experimental results. Finally, through finite element simulation, the behaviour of the abdominal wall was modelled before and after surgical mesh implant. Uniaxial loading of mesh samples in two perpendicular directions revealed the isotropic response of Surgipro® and the anisotropic behaviour of Optilene® and Infinit®. A phenomenological constitutive law was used to reproduce the measured experimental curves. To analyze the mechanical effect of the meshes once implanted in the abdomen, finite element simulation of the healthy and partially herniated repaired rabbit abdominal wall served to reproduce wall behaviour before and after mesh implant. In all cases, maximal displacements were lower and maximal principal stresses higher in the implanted abdomen than the intact wall model. Despite the fact that no mesh showed a behaviour that perfectly matched that of abdominal muscle, the Infinit® mesh was able to best comply with the biomechanics of the abdominal wall. Copyright © 2011 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  4. The effects of a slow release GnRH agonist implant on male rabbits

    DEFF Research Database (Denmark)

    Goericke-Pesch, Sandra Kathrin; Groeger, Gesa; Wehrend, Axel

    2015-01-01

    Surgical castration is done in male pet rabbits for reproduction control, to reduce inter-male aggression and to control hyper-sexuality, territory marking and aggression against humans. Alternatives to surgical castration are requested because of a relatively great anaesthetic risk in rabbits....... Long-term application of a GnRH agonist implant results in a fully reversible "hormonal" castration in male dogs, cats, boars and many other species. Therefore, the present study using New Zealand White hybrid and German Giant rabbits aimed to investigate the effects of a 4.7mg deslorelin implant...

  5. The Effect of Price on Surgeons' Choice of Implants: A Randomized Controlled Survey

    NARCIS (Netherlands)

    Wasterlain, Amy S.; Melamed, Eitan; Bello, Ricardo; Karia, Raj; Capo, John T.; Adams, Julie; Vochteloo, A. J. H.; Powell, Andrew John; Marcus, Alexander; Andreas, Platz; Miller, Anna N.; Berner, A. B. Arne; Altintas, Burak; Sears, Benjamin W.; Calfee, Ryan P.; Ekholm, Carl; Fernandes, C. H.; Porcellini, Giuseppe; Jones, Clifford; Moreno-Serrano, Constanza L.; Manke, Chad; Crist, Brett D.; Haverkamp, Daniel; Hanel, Doug; Merchant, Milind; Rikli, Daniel A.; Shafi, Mohamed; Patiño, Juan M.; Duncan, Scott F.; Ballas, Efsthathios G.; Harvey, Edward; Walbeehm, E. T.; Schumer, Evan D.; Evans, Peter J.; Suarez, Fabio; Lopez-Gonzalez, Francisco; Seibert, Franz Josef; DeSilva, Gregory; Bayne, Grant J.; Guitton, T. G.; Nancollas, Michael; Lane, Lewis B.; Westly, Stephen K.; Villamizar, Harold Alonso; Pountos, Ippokratis; Hofmeister, Eric; Biert, Jan; Goslings, J. Carel; Bishop, Julius; Peters, R. W.

    2017-01-01

    Surgical costs are under scrutiny and surgeons are being held increasingly responsible for cost containment. In some instances, implants are the largest component of total procedure cost, yet previous studies reveal that surgeons' knowledge of implant prices is poor. Our study aims to (1) understand

  6. Mechanical Properties of a Newly Additive Manufactured Implant Material Based on Ti-42Nb

    Directory of Open Access Journals (Sweden)

    Christian Schulze

    2018-01-01

    Full Text Available The application of Ti-6Al-4V alloy or commercially pure titanium for additive manufacturing enables the fabrication of complex structural implants and patient-specific implant geometries. However, the difference in Young’s modulus of α + β-phase Ti alloys compared to the human bone promotes stress-shielding effects in the implant–bone interphase. The aim of the present study is the mechanical characterization of a new pre-alloyed β-phase Ti-42Nb alloy for application in additive manufacturing. The present investigation focuses on the mechanical properties of SLM-printed Ti-42Nb alloy in tensile and compression tests. In addition, the raw Ti-42Nb powder, the microstructure of the specimens prior to and after compression tests, as well as the fracture occurring in tensile tests are characterized by means of the SEM/EDX analysis. The Ti-42Nb raw powder exhibits a dendrite-like Ti-structure, which is melted layer-by-layer into a microstructure with a very homogeneous distribution of Nb and Ti during the SLM process. Tensile tests display Young’s modulus of 60.51 ± 3.92 GPa and an ultimate tensile strength of 683.17 ± 16.67 MPa, whereas, under a compressive load, a compressive strength of 1330.74 ± 53.45 MPa is observed. The combination of high mechanical strength and low elastic modulus makes Ti-42Nb an interesting material for orthopedic and dental implants. The spherical shape of the pre-alloyed material additionally allows for application in metal 3D printing, enabling the fabrication of patient-specific structural implants.

  7. Functional outcome in subretinal electronic implants depends on foveal eccentricity.

    Science.gov (United States)

    Stingl, Katarina; Bartz-Schmidt, Karl-Ulrich; Gekeler, Florian; Kusnyerik, Akos; Sachs, Helmut; Zrenner, Eberhart

    2013-11-19

    An active microelectronic subretinal implant, developed to replace the photoreceptive function in hereditary degenerations of the outer retina, has been applied in a pilot and clinical study in patients with end-stage retinal degeneration. The study population comprised 20 blind patients, all of whom lost vision as result of a hereditary retinal disease. An active visual implant was placed surgically within the subretinal space of each patient: subfoveal placement in eight patients (group 1) and parafoveal placement in 12 (group 2). Standardized low-vision tests, including light perception, light localization, movement detection, grating acuity, and visual acuity by Landolt C-rings, were used under masked, randomized implant-OFF and implant-ON conditions. For the chip-mediated vision functional results of both subject groups were compared. Three of 20 patients were excluded from analysis because of surgical or technical implant issues. Among patients with nonfoveal placement of the implant, 80% could perceive light, 10% recognized location, and 10% correctly distinguished stripe patterns up to a resolution of 0.33 cycles/degree. No nonfoveal placement patient passed the motion or Landolt C-ring tests. When the implant was placed subfoveally, 100% of patients could perceive light and determine light localization, 75% could resolve motion up to 35°/s, 88% correctly distinguished stripe patterns up to a resolution of 3.3 cycles/degree, and 38% passed a Landolt C-ring test with a decimal visual acuity of up to 20/546 (logMAR 1.43). Subfoveal placement of active subretinal visual implants allows superior measurable outcomes compared to para- or nonfoveal placement locations. (ClinicalTrials.gov numbers, NCT01024803, NCT00515814.).

  8. Biventricular pacemaker implantation with the BV Pulsera

    Energy Technology Data Exchange (ETDEWEB)

    Wright, J.D.W.; Todd, D.; Waktare, J.E.P.; Hughes, S.; Abell, C. [The Cardiothoracic Centre, Liverpool (United Kingdom)

    2005-07-01

    The BV Pulsera mobile X-ray system is used for biventricular pacemaker implantation in a surgical environment. It provides high-quality images of the moving structures, including the fine coronary leads, and can be used for long fluoroscopy runs without overheating. (orig.)

  9. Biventricular pacemaker implantation with the BV Pulsera

    International Nuclear Information System (INIS)

    Wright, J.D.W.; Todd, D.; Waktare, J.E.P.; Hughes, S.; Abell, C.

    2005-01-01

    The BV Pulsera mobile X-ray system is used for biventricular pacemaker implantation in a surgical environment. It provides high-quality images of the moving structures, including the fine coronary leads, and can be used for long fluoroscopy runs without overheating. (orig.)

  10. Osteodistraction With Dental Implant-Borne Devices for Bone Regeneration in Atrophied Premaxilla.

    Science.gov (United States)

    Carlino, Francesco; Villani, Gian Piero; Berti, Andrea; Pantaleo, Giuseppe; Cortese, Antonio; Claudio, Pier Paolo

    2016-11-01

    Aim of this work is to present the evolution of an innovative technique for tooth/implant supported bone distraction, leading to proper oral rehabilitation in patients with atrophic alveolar bone, even when a complete premaxilla expansion is needed, or in patients in whom implants were already present, but inserted in wrong position.Distraction osteogenesis was selected because of its moderate invasiveness, the few surgical steps needed, and the proper cost/benefits balance. This procedure is particularly suited for young patients with remarkable aesthetic demands related to active social and working life, as for elderly patients expecting lower surgical stress and risks.

  11. Placement of replace select Ti-Unite-coated type implants using a combination of immediate and submerge techniques after tooth extraction

    Directory of Open Access Journals (Sweden)

    Coen Pramono D

    2006-06-01

    Full Text Available The high success rate of immediate implant placement both in the anterior and posterior regions were reported by many authors, therefore applying this techniques can be considered as a safe surgical procedure and minimizing the dental office visit for patient satisfaction. This paper reports the outcome of immediate placement of implants following extraction of anterior maxillary teeth. Combination technique of immediate and submerge implant placements including bone grafting procedure were used. Four implants with TiUnite surface type were placed immediately in two patients with the short-term result indicated that this technique may serve as a simple and safe procedure for immediate implant placement. It was concluded that immediate implant placement technique combined with TiUnite implant surface was successful in treating region directly after tooth extraction therefore this technique can be use as an alternative surgical method for dental implant rehabilitation.

  12. Scala vestibuli cochlear implantation in patients with partially ossified cochleas.

    Science.gov (United States)

    Berrettini, Stefano; Forli, Francesca; Neri, Emanuele; Segnini, Giovanni; Franceschini, Stefano Sellari

    2002-11-01

    Partial cochlear obstruction is a relatively common finding in candidates for cochlear implants and frequently involves the inferior segment of the scala tympani in the basal turn of the cochlea. In such patients, the scala vestibuli is often patent and offers an alternative site for implantation. The current report describes two patients with such partial obstruction of the inferior segment of the basal cochlear turn, caused in one case by systemic vasculitis (Takayasu's disease) and in the other by obliterative otosclerosis. A scala vestibuli implantation allowed for complete insertion of the electrode array. No problems were encountered during the surgical procedures and the good post-operative hearing and communicative outcomes achieved were similar to those reported in patients without cochlear ossification. The importance of accurate pre-operative radiological study of the inner ear is underscored, to disclose the presence and define the features of the cochlear ossification and ultimately to properly plan the surgical approach.

  13. Controlling the Biomimetic Implant Interface: Modulating Antimicrobial Activity by Spacer Design

    Science.gov (United States)

    Wisdom, Cate; Vanoosten, Sarah Kay; Boone, Kyle W.; Khvostenko, Dmytro; Arnold, Paul M.; Snead, Malcolm L.; Tamerler, Candan

    2016-08-01

    Surgical site infection is a common cause of post-operative morbidity, often leading to implant loosening, ultimately requiring revision surgery, increased costs and worse surgical outcomes. Since implant failure starts at the implant surface, creating and controlling the bio-material interface will play a critical role in reducing infection while improving host cell-to-implant interaction. Here, we engineered a biomimetic interface based upon a chimeric peptide that incorporates a titanium binding peptide (TiBP) with an antimicrobial peptide (AMP) into a single molecule to direct binding to the implant surface and deliver an antimicrobial activity against S. mutans and S. epidermidis, two bacteria which are linked with clinical implant infections. To optimize antimicrobial activity, we investigated the design of the spacer domain separating the two functional domains of the chimeric peptide. Lengthening and changing the amino acid composition of the spacer resulted in an improvement of minimum inhibitory concentration by a three-fold against S. mutans. Surfaces coated with the chimeric peptide reduced dramatically the number of bacteria, with up to a nine-fold reduction for S. mutans and a 48-fold reduction for S. epidermidis. Ab initio predictions of antimicrobial activity based on structural features were confirmed. Host cell attachment and viability at the biomimetic interface were also improved compared to the untreated implant surface. Biomimetic interfaces formed with this chimeric peptide offer interminable potential by coupling antimicrobial and improved host cell responses to implantable titanium materials, and this peptide based approach can be extended to various biomaterials surfaces.

  14. Short dental implants versus standard dental implants placed in the posterior jaws: A systematic review and meta-analysis.

    Science.gov (United States)

    Lemos, Cleidiel Aparecido Araujo; Ferro-Alves, Marcio Luiz; Okamoto, Roberta; Mendonça, Marcos Rogério; Pellizzer, Eduardo Piza

    2016-04-01

    The purpose of the present systematic review and meta-analysis was to compare short implants (equal or less than 8mm) versus standard implants (larger than 8mm) placed in posterior regions of maxilla and mandible, evaluating survival rates of implants, marginal bone loss, complications and prosthesis failures. This review has been registered at PROSPERO under the number CRD42015016588. Main search terms were used in combination: dental implant, short implant, short dental implants, short dental implants posterior, short dental implants maxilla, and short dental implants mandible. An electronic search for data published up until September/2015 was undertaken using the PubMed/Medline, Embase and The Cochrane Library databases. Eligibility criteria included clinical human studies, randomized controlled trials and/or prospective studies, which evaluated short implants in comparison to standard implants in the same study. The search identified 1460 references, after inclusion criteria 13 studies were assessed for eligibility. A total of 1269 patients, who had received a total of 2631 dental implants. The results showed that there was no significant difference of implants survival (P=.24; RR:1.35; CI: 0.82-2.22), marginal bone loss (P=.06; MD: -0.20; CI: -0.41 to 0.00), complications (P=.08; RR:0.54; CI: 0.27-1.09) and prosthesis failures (P=.92; RR:0.96; CI: 0.44-2.09). Short implants are considered a predictable treatment for posterior jaws. However, short implants with length less than 8 mm (4-7 mm) should be used with caution because they present greater risks to failures compared to standard implants. Short implants are frequently placed in the posterior area in order to avoid complementary surgical procedures. However, clinicians need to be aware that short implants with length less than 8mm present greater risk of failures. Copyright © 2016. Published by Elsevier Ltd.

  15. functional outcome and quality of life after surgical management

    African Journals Online (AJOL)

    Objective: To determine the functional outcome and quality of life of acetabular ... Outcome measures: Modified Merle d'Aubigne scale and “Squat and Smile” test for functional outcome. ..... limited number of implants, few surgical instruments.

  16. [The Léon [correction of Laurent] Guedj implant concept: simplification of the surgical phase in implantology].

    Science.gov (United States)

    Fabie, L; Guedj, L; Pichaud, Ch; Fabie, M

    2002-11-01

    We present a new self-drilling self-tapping dental implant that simplifies the operative technique and optimizes osseointegration. The implant, the instrumentation, and the operative technique are described. An experimental study was conducted in a sheep with pathological and histomorphological analysis at three months. A clinical evaluation was also conducted in 18 patients who had 27 implants. The experimental study demonstrated good quality osseointegration, without bone necrosis. Three sectors were identified. Histomorphometric analysis demonstrated that mean bone contact reached 40% on cancellous bone and 65% on cortical bone. In the clinical series, one implant had to be removed due to a problem with gum healing. All the other implants were well tolerated. The advantage of this new technique is the use of the implant as the drilling instrument. Much time is saved. In addition, the bone-implant contact is better since the bone cavity is exactly adapted to the implant. The risk of bone lesion is reduced due to the smaller number of drillings.

  17. Los implantes MG-OSSEOUS: Estudio multicéntrico retrospectivo MG-OSSEOUS implants: A multicentric retrospective study

    Directory of Open Access Journals (Sweden)

    E. Serrano Caturla

    2006-12-01

    commercial implants. Material and methodology. This is a retrospective multicentric study coordinated by a company called Scientific Management in O&SS (Barcelona, Spain. 1001 dental implants were placed in 247 patients and 328 prostheses were designed between 2004 and 2005, with a follow-up of two years. All implants were loaded with prostheses. We detail and analyze each implant, according to the diameter, length, position, surgical timing, loadings, design and types of prostheses and complementary surgical procedures, either synchronic or metachronic. Results. After the statistical method was homogenized, we were able to report an overall implant survival rate of 97.8% with monitoring of two years. The failures depending on the peculiarities of each clinical case are provided. No prosthetic failures are reported. Discussion. The criteria and indications applied by the professionals to the MG-OSSEOUS implants are standardized depending on the clinical case. Our results are compared with the international scientific literature, past and present, with these procedures totally agreeing with those found in the history of implantology. Finally, our survey is compared with those published by the Branemark team. Conclusion. The mixture between the quality of the MGOSSEOUS implants and the scientifically supported criteria regarding the implants, reveals an implant failure of 2.2% over two years, with a survival of 100% of both the replaced implants and the loaded prostheses.

  18. Median Sternotomy or Right Thoracotomy Techniques for Total Artificial Heart Implantation in Calves.

    Science.gov (United States)

    Karimov, Jamshid H; Moazami, Nader; Sunagawa, Gengo; Kobayashi, Mariko; Byram, Nicole; Sale, Shiva; Such, Kimberly A; Horvath, David J; Golding, Leonard A R; Fukamachi, Kiyotaka

    2016-10-01

    The choice of optimal operative access technique for mechanical circulatory support device implantation ensures successful postoperative outcomes. In this study, we retrospectively evaluated the median sternotomy and lateral thoracotomy incisions for placement of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) in a bovine model. The CFTAH was implanted in 17 calves (Jersey calves; weight range, 77.0-93.9 kg) through a median sternotomy (n = 9) or right thoracotomy (n = 8) for elective chronic implantation periods of 14, 30, or 90 days. Similar preoperative preparation, surgical techniques, and postoperative care were employed. Implantation of the CFTAH was successfully performed in all cases. Both methods provided excellent surgical field visualization. After device connection, however, the median sternotomy approach provided better visualization of the anastomoses and surgical lines for hemostasis confirmation and repair due to easier device displacement, which is severely limited following right thoracotomy. All four animals sacrificed after completion of the planned durations (up to 90 days) were operated through full median sternotomy. Our data demonstrate that both approaches provide excellent initial field visualization. Full median sternotomy provides larger viewing angles at the anastomotic suture line after device connection to inflow and outflow ports. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  19. New horizon for infection prevention technology and implantable device

    Directory of Open Access Journals (Sweden)

    Yusuke Kondo, MD, PhD

    2016-08-01

    Full Text Available There has been a significant increase in the number of patients receiving cardiovascular implantable electronic devices (CIED over the last two decades. CIED infection represents a serious complication after CIED implantation and is associated with significant morbidity and mortality. Recently, newly advanced technologies have offered attractive and suitable therapeutic alternatives. Notably, the leadless pacemaker and anti-bacterial envelope decrease the potential risk of CIED infection and the resulting mortality, when it does occur. A completely subcutaneous implantable cardioverter defibrillator is also an alternative to the transvenous implantable cardioverter defibrillator (ICD, as it does not require implantation of any transvenous or epicardial leads. Among the patients who require ICD removal and subsequent antibiotics secondary to infection, the wearable cardioverter defibrillator represents an alternative approach to inpatient monitoring for the prevention of sudden cardiac death. In this review paper, we aimed to introduce the advanced technologies and devices for prevention of CIED infection.

  20. Chemical characterization of 4140 steel implanted by nitrogen ions

    International Nuclear Information System (INIS)

    Niño, E D V; Dugar-Zhabon, V; Pinto, J L; Henao, J A

    2012-01-01

    AISI SAE 4140 steel samples of different surface roughness which are implanted with 20 keV and 30 keV nitrogen ions at a dose of 10 17 ions/cm 2 are studied. The crystal phases of nitrogen compositions of the implanted samples, obtained with help of an x-ray diffraction method, are confronted with the data reported by the International Centre for Diffraction Data (ICDD) PDF-2. The implantation treatment is realized in high-voltage pulsed discharges at low pressures. The crystal structure of the implanted solid surfaces is analyzed by the x-ray diffraction technique which permits to identify the possible newly formed compounds and to identify any change in the surface structure of the treated samples. A decrease in the intensity of the plane (110), a reduction of the cell unity in values of 2-theta and a diminishing of the crystallite dimensions in comparison with non-implanted samples are observed.

  1. Chemical characterization of 4140 steel implanted by nitrogen ions

    Science.gov (United States)

    Niño, E. D. V.; Pinto, J. L.; Dugar-Zhabon, V.; Henao, J. A.

    2012-06-01

    AISI SAE 4140 steel samples of different surface roughness which are implanted with 20 keV and 30 keV nitrogen ions at a dose of 1017 ions/cm2 are studied. The crystal phases of nitrogen compositions of the implanted samples, obtained with help of an x-ray diffraction method, are confronted with the data reported by the International Centre for Diffraction Data (ICDD) PDF-2. The implantation treatment is realized in high-voltage pulsed discharges at low pressures. The crystal structure of the implanted solid surfaces is analyzed by the x-ray diffraction technique which permits to identify the possible newly formed compounds and to identify any change in the surface structure of the treated samples. A decrease in the intensity of the plane (110), a reduction of the cell unity in values of 2-theta and a diminishing of the crystallite dimensions in comparison with non-implanted samples are observed.

  2. Preventing Bacterial Infections using Metal Oxides Nanocoatings on Bone Implant

    Science.gov (United States)

    Duceac, L. D.; Straticiuc, S.; Hanganu, E.; Stafie, L.; Calin, G.; Gavrilescu, S. L.

    2017-06-01

    Nowadays bone implant removal is caused by infection that occurs around it possibly acquired after surgery or during hospitalization. The purpose of this study was to reveal some metal oxides applied as coatings on bone implant thus limiting the usual antibiotics-resistant bacteria colonization. Therefore ZnO, TiO2 and CuO were synthesized and structurally and morphologically analized in order to use them as an alternative antimicrobial agents deposited on bone implant. XRD, SEM, and FTIR characterization techniques were used to identify structure and texture of these nanoscaled metal oxides. These metal oxides nanocoatings on implant surface play a big role in preventing bacterial infection and reducing surgical complications.

  3. Effect of a Rapidly Degrading Presolidified 10 kDa Chitosan/Blood Implant and Subchondral Marrow Stimulation Surgical Approach on Cartilage Resurfacing in a Sheep Model

    Science.gov (United States)

    Bell, Angela D.; Hurtig, Mark B.; Quenneville, Eric; Rivard, Georges-Étienne; Hoemann, Caroline D.

    2016-01-01

    Objective This study tested the hypothesis that presolidified chitosan-blood implants are retained in subchondral bone channels perforated in critical-size sheep cartilage defects, and promote bone repair and hyaline-like cartilage resurfacing versus blood implant. Design Cartilage defects (10 × 10 mm) with 3 bone channels (1 drill, 2 Jamshidi biopsy, 2 mm diameter), and 6 small microfracture holes were created bilaterally in n = 11 sheep knee medial condyles. In one knee, 10 kDa chitosan–NaCl/blood implant (presolidified using recombinant factor VIIa or tissue factor), was inserted into each drill and Jamshidi hole. Contralateral knee defects received presolidified whole blood clot. Repair tissues were assessed histologically, biochemically, biomechanically, and by micro–computed tomography after 1 day (n = 1) and 6 months (n = 10). Results Day 1 defects showed a 60% loss of subchondral bone plate volume fraction along with extensive subchondral hematoma. Chitosan implant was resident at day 1, but had no effect on any subsequent repair parameter compared with blood implant controls. At 6 months, bone defects exhibited remodeling and hypomineralized bone repair and were partly resurfaced with tissues containing collagen type II and scant collagen type I, 2-fold lower glycosaminoglycan and fibril modulus, and 4.5-fold higher permeability compared with intact cartilage. Microdrill holes elicited higher histological ICRS-II overall assessment scores than Jamshidi holes (50% vs. 30%, P = 0.041). Jamshidi biopsy holes provoked sporadic osteonecrosis in n = 3 debrided condyles. Conclusions Ten kilodalton chitosan was insufficient to improve repair. Microdrilling is a feasible subchondral marrow stimulation surgical approach with the potential to elicit poroelastic tissues with at least half the compressive modulus as intact articular cartilage. PMID:28934884

  4. Effect of a Rapidly Degrading Presolidified 10 kDa Chitosan/Blood Implant and Subchondral Marrow Stimulation Surgical Approach on Cartilage Resurfacing in a Sheep Model.

    Science.gov (United States)

    Bell, Angela D; Hurtig, Mark B; Quenneville, Eric; Rivard, Georges-Étienne; Hoemann, Caroline D

    2017-10-01

    Objective This study tested the hypothesis that presolidified chitosan-blood implants are retained in subchondral bone channels perforated in critical-size sheep cartilage defects, and promote bone repair and hyaline-like cartilage resurfacing versus blood implant. Design Cartilage defects (10 × 10 mm) with 3 bone channels (1 drill, 2 Jamshidi biopsy, 2 mm diameter), and 6 small microfracture holes were created bilaterally in n = 11 sheep knee medial condyles. In one knee, 10 kDa chitosan-NaCl/blood implant (presolidified using recombinant factor VIIa or tissue factor), was inserted into each drill and Jamshidi hole. Contralateral knee defects received presolidified whole blood clot. Repair tissues were assessed histologically, biochemically, biomechanically, and by micro-computed tomography after 1 day ( n = 1) and 6 months ( n = 10). Results Day 1 defects showed a 60% loss of subchondral bone plate volume fraction along with extensive subchondral hematoma. Chitosan implant was resident at day 1, but had no effect on any subsequent repair parameter compared with blood implant controls. At 6 months, bone defects exhibited remodeling and hypomineralized bone repair and were partly resurfaced with tissues containing collagen type II and scant collagen type I, 2-fold lower glycosaminoglycan and fibril modulus, and 4.5-fold higher permeability compared with intact cartilage. Microdrill holes elicited higher histological ICRS-II overall assessment scores than Jamshidi holes (50% vs. 30%, P = 0.041). Jamshidi biopsy holes provoked sporadic osteonecrosis in n = 3 debrided condyles. Conclusions Ten kilodalton chitosan was insufficient to improve repair. Microdrilling is a feasible subchondral marrow stimulation surgical approach with the potential to elicit poroelastic tissues with at least half the compressive modulus as intact articular cartilage.

  5. Treatment of an Erratic Extraction Socket for Implant Therapy in a Patient with Chronic Periodontitis

    Directory of Open Access Journals (Sweden)

    Yusuke Hamada

    2016-01-01

    Full Text Available As implant therapy becomes more commonplace in daily practice, preservation and preparation of edentulous sites are key. Many times, however, implant therapy may not be considered at the time of tooth extraction and additional measures are not taken to conserve the edentulous site. While the healing process in extraction sockets has been well investigated and bone fill can be expected, there are cases where even when clinicians perform thorough debridement of the sockets, connective tissue infiltration into the socket can occur. This phenomenon, known as “erratic healing,” may be associated with factors that lead to peri-implant disease and should be appropriately managed and treated prior to surgical implant placement. This case report describes the successful management of an erratic healing extraction socket in a 62-year-old Caucasian male patient with chronic periodontitis and the outcomes of an evidence-based treatment protocol performed prior to implant therapy. Careful preoperative analysis and cone beam computed tomography imaging can help detect signs of impaired healing in future implant sites and prevent surgical complications.

  6. Treatment of an Erratic Extraction Socket for Implant Therapy in a Patient with Chronic Periodontitis

    Science.gov (United States)

    Prabhu, Srividya

    2016-01-01

    As implant therapy becomes more commonplace in daily practice, preservation and preparation of edentulous sites are key. Many times, however, implant therapy may not be considered at the time of tooth extraction and additional measures are not taken to conserve the edentulous site. While the healing process in extraction sockets has been well investigated and bone fill can be expected, there are cases where even when clinicians perform thorough debridement of the sockets, connective tissue infiltration into the socket can occur. This phenomenon, known as “erratic healing,” may be associated with factors that lead to peri-implant disease and should be appropriately managed and treated prior to surgical implant placement. This case report describes the successful management of an erratic healing extraction socket in a 62-year-old Caucasian male patient with chronic periodontitis and the outcomes of an evidence-based treatment protocol performed prior to implant therapy. Careful preoperative analysis and cone beam computed tomography imaging can help detect signs of impaired healing in future implant sites and prevent surgical complications. PMID:27807485

  7. Treatment of an Erratic Extraction Socket for Implant Therapy in a Patient with Chronic Periodontitis.

    Science.gov (United States)

    Hamada, Yusuke; Prabhu, Srividya; John, Vanchit

    2016-01-01

    As implant therapy becomes more commonplace in daily practice, preservation and preparation of edentulous sites are key. Many times, however, implant therapy may not be considered at the time of tooth extraction and additional measures are not taken to conserve the edentulous site. While the healing process in extraction sockets has been well investigated and bone fill can be expected, there are cases where even when clinicians perform thorough debridement of the sockets, connective tissue infiltration into the socket can occur. This phenomenon, known as "erratic healing," may be associated with factors that lead to peri-implant disease and should be appropriately managed and treated prior to surgical implant placement. This case report describes the successful management of an erratic healing extraction socket in a 62-year-old Caucasian male patient with chronic periodontitis and the outcomes of an evidence-based treatment protocol performed prior to implant therapy. Careful preoperative analysis and cone beam computed tomography imaging can help detect signs of impaired healing in future implant sites and prevent surgical complications.

  8. Cochlear Implantation in Patients with Neurofibromatosis Type 2 and Patients with Vestibular Schwannoma in the Only Hearing Ear

    Directory of Open Access Journals (Sweden)

    Erika Celis-Aguilar

    2012-01-01

    Full Text Available Cochlear implants are a new surgical option in the hearing rehabilitation of patients with neurofibromatosis type 2 (NF2 and patients with vestibular schwannoma (VS in the only hearing ear. Auditory brainstem implant (ABI has been the standard surgical treatment for these patients. We performed a literature review of patients with NF2 and patients with VS in the only hearing ear. Cochlear implantation (CI provided some auditory benefit in all patients. Preservation of cochlear nerve integrity is crucial after VS resection. Results ranged from environmental sound awareness to excellent benefit with telephone use. Promontory stimulation is recommended although not crucial. MRI can be performed safely in cochlear implanted patients.

  9. Conservative surgical management of placenta accreta: a report of 3 cases.

    Science.gov (United States)

    Pliskow, Steven; Dai, Xiaorong; Kohner, Andrew; Kapnick, Jason

    2009-10-01

    Placenta accreta is often diagnosed at the time of delivery and is a cause of postpartum hemorrhage, morbidity and mortality. The standard treatment for placenta accreta is hysterectomy to avoid acute blood loss and shock. A conservative surgical approach to the treatment of placenta accreta will allow immediate cure while preserving the patient's future fertility. A 39-year-old woman with placenta accreta diagnosed at the time of vaginal delivery was successfully treated with resection of the placental implantation site. A 33-year-old woman and a 35-year-old woman with placenta accreta/increta diagnosed at the time of cesarean section were successfully treated with resection of the placental implantation site. One patient has since conceived and given birth. Placenta accreta and placenta increta can be safely and successfully treated, in some well-selected cases, by resection of the placental implantation site and uterine repair. This conservative surgical management provides immediate therapy, reduces blood loss and preserves fertility.

  10. Evaluating the Effectiveness of Biomaterial Removal from Dental Implant Drills

    Science.gov (United States)

    2016-06-13

    dental implant drills. More research is indicated to differentiate surgical debris from solution remnants, to verify results with different cleaning...In the past 50 years, research studies evaluating the effectiveness of cleaning dental instruments focused primarily on endodontic files and dental...of 1.64 implants per visit (T Oringderff, oral communication, APR 2016); combined with the additional use of a starter drill and the possible use

  11. Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design

    Directory of Open Access Journals (Sweden)

    Domenico Baldi

    2018-01-01

    Full Text Available Aim. To evaluate the correlation between insertion torque (IT and implant stability quotient (ISQ in tapered implants with knife-edge threads. Methods. Seventy-five identical implants (Anyridge, Megagen were inserted by using a surgical drilling unit with torque control and an integrated resonance frequency analysis module (Implantmed, W&H. IT (N/cm and ISQ were recorded and implants were divided into three groups (n=25 according to the IT: low (50. ISQ difference among groups was assessed by Kruskal-Wallis test, followed by Bonferroni-corrected Mann–Whitney U-test for pairwise comparisons. The strength of the association between IT and ISQ was assessed by Spearman Rho correlation coefficient (α=0.05. Results. At the pairwise comparisons, a significant difference of ISQ values was demonstrated only between low torque and high torque groups. The strength of the association between IT and ISQ value was significant for both the entire sample and the medium torque group, while it was not significant in low and high torque groups. Conclusions. For the investigated implant, ISQ and IT showed a positive correlation up to values around 50 N/cm: higher torques subject the bone-implant system to unnecessary biological and mechanical stress without additional benefits in terms of implant stability. This trial is registered with NCT03222219.

  12. Preservation of keratinized mucosa around implants using a prefabricated implant-retained stent: a case-control study

    Science.gov (United States)

    2016-01-01

    Purpose The aim of this study was to clinically assess the impact of a prefabricated implant-retained stent clipped over healing abutments on the preservation of keratinized mucosa around implants after implant surgery, and to compare it with horizontal external mattress sutures. Methods A total of 50 patients were enrolled in this study. In the test group, a prefabricated implant-retained stent was clipped on the healing abutment after implant surgery to replace the keratinized tissue bucco-apically. In the control group, horizontal external mattress sutures were applied instead of using a stent. After the surgical procedure, the width of the buccal keratinized mucosa was measured at the mesial, middle, and distal aspects of the healing abutment. The change in the width of the buccal keratinized mucosa was assessed at 1 and 3 months. Results Healing was uneventful in both groups. The difference of width between baseline and 1 month was −0.26±0.85 mm in the test group, without any statistical significance (P=0.137). Meanwhile, the corresponding difference in the control group was −0.74±0.73 mm and it showed statistical significance (Pprefabricated implant-retained stent was shown to be effective in the preservation of the keratinized mucosa around implants and it was simple and straightforward in comparison to the horizontal external mattress suture technique. PMID:27800215

  13. Different types of implants for reconstructive breast surgery.

    Science.gov (United States)

    Rocco, Nicola; Rispoli, Corrado; Moja, Lorenzo; Amato, Bruno; Iannone, Loredana; Testa, Serena; Spano, Andrea; Catanuto, Giuseppe; Accurso, Antonello; Nava, Maurizio B

    2016-05-16

    Breast cancer is the most common cancer in women worldwide, and is a leading cause of cancer death among women. Prophylactic or curative mastectomy is often followed by breast reconstruction for which there are several surgical approaches that use breast implants with which surgeons can restore the natural feel, size and shape of the breast. To assess the effects of different types of breast implants on capsular contracture, surgical short- and long-term complications, postoperative satisfaction level and quality of life in women who have undergone reconstructive breast surgery after mastectomy. We searched the Cochrane Breast Cancer Group's Specialised Register on 20 July 2015, MEDLINE (1985 to 20 July 2015), EMBASE (1985 to 20 July 2015) and the Cochrane Central Register of Controlled Trials (CENTRAL; Issue 8, 2015). We also searched the World Health Organization's International Clinical Trials Registry Platform (WHO ICTRP) and ClinicalTrials.gov on 16 July 2015. We included randomised controlled trials (RCTs) and quasi-RCTs that compared different types of breast implants for reconstructive surgery. We considered the following types of intervention: implant envelope surfaces - texturised versus smooth; implant filler material - silicone versus saline, PVP-Hydrogel versus saline; implant shape - anatomical versus round; implant volume - variable versus fixed; brands - different implant manufacturing companies and implant generation (fifth versus previous generations). Two review authors independently assessed methodological quality and extracted data. We used standard Cochrane methodological procedures. The quality of the evidence was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. Five RCTs with 202 participants met the inclusion criteria. The women participants were typically in their 50s, and the majority of them (about 82%) received reconstructive surgery following breast cancer, while the others had

  14. Implant decontamination with 2% chlorhexidine during surgical peri-implantitis treatment : a randomized, double-blind, controlled trial

    NARCIS (Netherlands)

    de Waal, Y. C. M.; Raghoebar, G. M.; Meijer, H. J. A.; Winkel, E. G.; van Winkelhoff, A. J.

    ObjectiveThe objective of this randomized, double-blind, controlled trial was to evaluate the clinical, radiographic, and microbiological effects of implant surface decontamination with a 2% chlorhexidine (CHX) solution in comparison with a 0.12% chlorhexidine+0.05% cetylpyridinium chloride (CPC)

  15. Costal bone abnormalities: an unusual cause of spontaneous bilateral breast implant deflation†

    Science.gov (United States)

    Brooker, Jack E.; Gusenoff, Jeffrey A.

    2014-01-01

    Augmentation mammoplasty is the most common aesthetic surgical procedure performed in the USA. Prosthetic failure is a major reason for surgical reintervention. A number of causes for this have been documented, but costal bone abnormalities leading to perforation of the prosthesis are very unusual. We present the case of a woman who experienced spontaneous deflation of both saline implants in close succession, and who was found to have sharp bony spicules on both sides of her chest. Pathology examination reported reactive changes, suggestive of heterotopic bone. Examination of the implants showed no defects besides small punctures on the back wall, which coincided with the position of the spicules of bone. There are a number of possible causes for these bony growths which we examine in turn. The chest wall should be examined in all cases where unexplained implant deflation has occurred. PMID:25535321

  16. Advanced immediate functional loading: requirements for long-term success in modern implant dentistry.

    Science.gov (United States)

    Romanos, Georgios E

    2014-01-01

    There are benefits to be derived from the use of advanced surgical protocols in conjunction with immediate functional loading using various dental implant designs and implant-abutment connections. Clinical protocols with simultaneous bone grafting, immediate implant placement, and/or sinus augmentations when a shortened treatment period is needed are included in this report, with the aim of providing understanding of the main protocol characteristics and prerequisites for long-term success in implant dentistry. This article presents three clinical cases that illustrate possibilities for advanced immediate loading using different implant designs. It demonstrates treatment of severe bone defects and the facilitation of placing implants in regenerated bone that can be immediately loaded.

  17. Evaluation of 4 mm implants in mandibular edentulous patients with reduced bone height. Surgical preliminary results

    Directory of Open Access Journals (Sweden)

    J.L. Calvo-Guirado

    2014-06-01

    Full Text Available Aim: Growing evidence has suggested the utility of short dental implants for oral reconstructive procedures in clinical situations of limited vertical bone height. The aim of this short comunication was to evaluate the clinical use of implants < 10 mm in length and to determine short implant-supported prosthesis success in the atrophic jaw. Materials and methods: Six women and three men were recruited for the treatment of edentulous mandibles. A total of 6 implants were inserted in each patient: two anterior implants of conventional lenght and four posterior 4 mm Titanium Zirconium (TiZr implants. The insertion torque and bone denisty were evaluated. Results: The mean insertion torque for the 4 mm implants was lower than for conventional ones, without any statistical difference. Moreover, most of the patients (88% showed a D2 bone type. Conclusion: The provision of short implant-supported prostheses in patients with atrophic alveolar ridges appears to be a successful treatment option in the short term; however, more scientific evidence is needed for the long term.

  18. Initial experience of two national centers in transcatheter aortic prosthesis implantation.

    Science.gov (United States)

    Lluberas, Sebastián; Abizaid, Alexandre; Siqueira, Dimytri; Ramos, Auristela; Costa, J Ribamar; Arrais, Magaly; Kambara, Antônio; Bihan, David Le; Sousa, Amanda; Sousa, J Eduardo

    2014-04-01

    Transcatheter aortic valve implantation is an effective alternative to surgical treatment of severe aortic stenosis in patients who are inoperable or at high surgical risk. To report the immediate and follow-up clinical and echocardiographic results of the initial experience of transcatheter aortic valve implantation. From 2009 June to 2013 February, 112 patients underwent transcatheter aortic valve implantation. Mean age was 82.5 ± 6.5 years, and the logistic EuroSCORE was 23.6 ± 13.5. Procedural success was 84%. After the intervention, a reduction in the mean systolic gradient was observed (pre: 54.7 ± 15.3 vs. post: 11.7 ± 4.0 mmHg; p < 0.01). Cerebrovascular accidents occurred in 3.6%, vascular complications in 19% and permanent pacemaker was required by 13% of the patients. Thirty-day mortality and at follow-up of 16 ± 11 months was 14% and 8.9% respectively. The presence of chronic obstructive pulmonary disease was the only predictor of mortality at 30 days and at follow-up. During follow up, aortic valve area and mean systolic gradient did not change significantly. Transcatheter aortic valve implantation is an effective and safe procedure for the treatment of aortic stenosis in high-surgical risk or inoperable patients. The presence of chronic obstructive pulmonary disease was the only independent predictor of mortality identified both in the first month post-intervention and at follow-up.

  19. Perioperative management for the prevention of bacterial infection in cardiac implantable electronic device placement

    Directory of Open Access Journals (Sweden)

    Katsuhiko Imai

    2016-08-01

    Full Text Available Cardiac implantable electronic devices (CIEDs have become important in the treatment of cardiac disease and placement rates increased significantly in the last decade. However, despite the use of appropriate antimicrobial prophylaxis, CIED infection rates are increasing disproportionately to the implantation rate. CIED infection often requires explantation of all hardware, and at times results in death. Surgical site infection (SSI is the most common cause of CIED infection as a pocket infection. The best method of combating CIED infection is prevention. Prevention of CIED infections comprises three phases: before, during, and after device implantation. The most critical factors in the prevention of SSIs are detailed operative techniques including the practice of proper technique by the surgeon and surgical team.

  20. Low permanent pacemaker rates following Lotus device implantation for transcatheter aortic valve replacement due to modified implantation protocol.

    Science.gov (United States)

    Krackhardt, Florian; Kherad, Behrouz; Krisper, Maximilian; Pieske, Burkert; Laule, Michael; Tschöpe, Carsten

    2017-01-01

    Conduction disturbances requiring permanent pacemaker implantation following transcatheter aortic valve replacement (TAVR) are a common problem. Pacemaker implantation rates after TAVR appear to be higher compared to conventional aortic valve replacement. The aim of this study was to analyze whether a high annulus implantation conveys the benefit of a decreased rate of permanent pacemaker implantation while being safe and successful according to Valve Academic Research Consortium 2 (VARC2)-criteria. A total of 23 patients with symptomatic severe aortic valve stenosis, an aortic annulus of 19-27 mm and at high risk for surgery were treated with the Lotus valve. In all patients the valve was implanted in a high annulus position via femoral access. The primary device performance endpoint was VARC2-defined device success after 30 days and the primary safety endpoint was the need for permanent pacemaker implantation. The mean age was 73.23 ± 7.65 years, 46% were female, 38% were New York Heart Association class III/IV at baseline. Thirty-day follow-up data were available for all patients. The VARC2-defined device success rate after 30 days was 22/23 (96%). 2/21 (10%) patients required a newly implanted pacemaker due to 3rd degree atrioventricular block. 25% of the patients developed a new left bundle branch block after valvuloplasty or device implantation. 21 of the 23 patients (96%) had no other signs of conduction disturbances after 30 days. The approach of the modified implantation technique of Lotus TAVR device was safe and effective. The incidence of need for a permanent pacemaker following TAVR could be significantly reduced due to adopted implantation protocol.

  1. [Surgical treatment with an artificial iris].

    Science.gov (United States)

    Mayer, C S; Hoffmann, A E

    2015-10-01

    Iris defects with their disturbed pupillary function, visual impairment and glare constitute a therapeutic challenge in surgical reconstruction. A new therapeutic option for distinctive defects consists in the implantation of a custom-made silicone iris. This new and challenging therapy provides the opportunity to achieve an individual, aesthetically appealing and good functional result for the patient.

  2. Surgical site infections following instrumented stabilization of the spine

    Directory of Open Access Journals (Sweden)

    Dapunt U

    2017-09-01

    Full Text Available Ulrike Dapunt,1 Caroline Bürkle,1 Frank Günther,2 Wojciech Pepke,1 Stefan Hemmer,1 Michael Akbar1 1Clinic for Orthopedics and Trauma Surgery, Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, Heidelberg University Hospital, 2Department for Infectious Diseases, Medical Microbiology and Hygiene, Heidelberg University, Heidelberg, Germany Background: Implant-associated infections are still a feared complication in the field of orthopedics. Bacteria attach to the implant surface and form so-called biofilm colonies that are often difficult to diagnose and treat. Since the majority of studies focus on prosthetic joint infections (PJIs of the hip and knee, current treatment options (eg, antibiotic prophylaxis of implant-associated infections have mostly been adapted according to these results. Objective: The aim of this study was to evaluate patients with surgical site infections following instrumented stabilization of the spine with regard to detected bacteria species and the course of the disease. Patients and methods: We performed a retrospective single-center analysis of implant-associated infections of the spine from 2010 to 2014. A total of 138 patients were included in the study. The following parameters were evaluated: C-reactive protein serum concentration, microbiological evaluation of tissue samples, the time course of the disease, indication for instrumented stabilization of the spine, localization of the infection, and the number of revision surgeries required until cessation of symptoms. Results: Coagulase-negative Staphylococcus spp. were most commonly detected (n=69, 50%, followed by fecal bacteria (n=46, 33.3%. In 23.2% of cases, no bacteria were detected despite clinical suspicion of an infection. Most patients suffered from degenerative spine disorders (44.9%, followed by spinal fractures (23.9%, non-degenerative scoliosis (20.3%, and spinal tumors (10.1%. Surgical site infections occurred predominantly within 3

  3. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  4. Power Approaches for Implantable Medical Devices

    Directory of Open Access Journals (Sweden)

    Achraf Ben Amar

    2015-11-01

    Full Text Available Implantable medical devices have been implemented to provide treatment and to assess in vivo physiological information in humans as well as animal models for medical diagnosis and prognosis, therapeutic applications and biological science studies. The advances of micro/nanotechnology dovetailed with novel biomaterials have further enhanced biocompatibility, sensitivity, longevity and reliability in newly-emerged low-cost and compact devices. Close-loop systems with both sensing and treatment functions have also been developed to provide point-of-care and personalized medicine. Nevertheless, one of the remaining challenges is whether power can be supplied sufficiently and continuously for the operation of the entire system. This issue is becoming more and more critical to the increasing need of power for wireless communication in implanted devices towards the future healthcare infrastructure, namely mobile health (m-Health. In this review paper, methodologies to transfer and harvest energy in implantable medical devices are introduced and discussed to highlight the uses and significances of various potential power sources.

  5. Effect of osteoporosis on fixation of osseointegrated implants in rats.

    Science.gov (United States)

    Li, Yunfeng; He, Sheng; Hua, Yunwei; Hu, Jing

    2017-11-01

    The effect of osteoporosis on implant osseointegration has been widely investigated, whereas osteoporosis may also newly occur in patient with previously osseointegrated implant. This study was designed to investigate the effect of osteoporosis on implant fixation in rats after successful osseointegration had been obtained. Seventy female Sprague-Dawley rats were included, and each animal received two titanium implants in the distal metaphysis of femur bilaterally. Eight weeks later, ten rats were sacrificed to confirm the establishment of implant osseointegration. All left rats were randomly subjected to bilateral ovariectomy (OVX) or sham operation. Three, six, and twelve weeks later, implant osseointegration, peri-implant bone tissue, and biomechanical properties of implant were analyzed. Right femurs with implants were used for micro-CT and histological analysis, and left femurs with implants were used for biomechanical test. Micro-CT, histology, and biomechanical test confirmed the destructive effect of OVX on previously osseointegrated implant in rats; when compared to sham-operated rats, peri-implant bone volume, trabecular architecture, bone-to-implant contact ratio, as well as biomechanical parameters decreased progressively within 12 weeks. Results also indicated that the effect of OVX on undisturbed bone (proximal tibiae) was much stronger than that on peri-implant bone. Osteoporosis produced a progressive negative effect on previously osseointegrated implant in distal femora of rats during 12 weeks. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2426-2432, 2017. © 2016 Wiley Periodicals, Inc.

  6. An update on implant placement and provisionalization in extraction, edentulous, and sinus-grafted sites. A clinical report on 3200 sites over 8 years.

    Science.gov (United States)

    Petrungaro, Paul S

    2008-06-01

    Provisionalization of dental implants at placement has become more prominent in the field of implantology over the past several years, especially in the esthetic zone. The benefits of this treatment option include immediate tooth replacement, formation and maintenance of esthetic soft-tissue contours, containment for bone-grafting and tissue-regenerative procedures, and an improved sense of the patient's perception of the implant process. The blending together of the surgical and prosthetic/esthetic phase has never been more important as implant systems, abutment options, and surgical techniques have helped optimize procedures that can be accomplished at the surgical visit. This article reviews the guidelines for surgical success first described by the author in 2003 and expands upon those results. This article highlights the results of more than 3200 immediately restored implants placed in edentulous, fresh extraction sockets, and sinus-grafted sites, over an 8-year period, and presents a case for each area of placement.

  7. Nanomechanical properties of bone around cement-retained abutment implants. A minipig study

    Directory of Open Access Journals (Sweden)

    R.R.M. de Barros

    2016-06-01

    Full Text Available Aim The nanomechanical evaluation can provide additional information about the dental implants osseointegration process. The aim of this study was to quantify elastic modulus and hardness of bone around cemented-retained abutment implants positioned at two different crestal bone levels. Materials and methods The mandibular premolars of 7 minipigs were extracted. After 8 weeks, 8 implants were inserted in each animal: crestally on one side of the mandible and subcrestally on the other (crestal and subcrestal groups. Functional loading were immediately provided with abutments cementation and prostheses installation. Eight weeks later, the animals euthanasia was performed and nanoindentation analyses were made at the most coronal newly formed bone region (coronal group, and below in the threaded region (threaded group of histologic sections. Results The comparisons between subcrestal and crestal groups did not achieve statistical relevance; however the elastic modulus and hardness levels were statistically different in the two regions of evaluation (coronal and threaded. Conclusions The crestal and subcrestal placement of cement-retained abutment implants did not affect differently the nanomechanical properties of the surrounding bone. However the different regions of newly formed bone (coronal and threaded groups were extremely different in both elastic modulus and hardness, probably reflecting their differences in bone composition and structure.

  8. Combined Glaucoma Tube Shunt (Ahmed) and Fluocinolone Acetonide (Retisert™) Implantation Compared to Ahmed Alone in Uveitic Glaucoma.

    Science.gov (United States)

    Zivney, Mark; Lin, Phoebe; Edmunds, Beth; Parikh, Mansi; Takusagawa, Hana; Tehrani, Shandiz

    2016-12-01

    Glaucoma is a known complication of uveitis, and may require glaucoma tube shunt implantation for intraocular pressure (IOP) control. The success of glaucoma tube shunt implantation in the setting of a local ocular steroid depot in uveitic glaucoma remains unknown. The purpose of this study was to determine whether patients who underwent combined glaucoma tube shunt (Ahmed) and fluocinolone acetonide (Retisert™, Bausch + Lomb, Bridgewater, NJ, USA) implantation have superior outcomes compared to patients with Ahmed implants only in the setting of uveitic glaucoma. All participants were studied retrospectively and underwent Ahmed implantation alone or with existing/concurrent Retisert implantation (combined group) at a single academic institution. The main outcome measures were IOP, visual acuity (VA), number of IOP-lowering medications, and adverse events at 6 months after Ahmed implantation. Secondary outcome measures included adverse events and surgical success at 6 months after Ahmed implantation. Mean IOP at 6 months after Ahmed implantation was 15.3 ± 4.8 and 15.1 ± 4.9 mm Hg in the Ahmed only group (n = 17) and the combined group (n = 17), respectively (p = 0.89). The mean number of IOP-lowering medications at 6 months after Ahmed implantation was 1.7 ± 1.0 and 1.8 ± 1.0 in the Ahmed only group and the combined group, respectively (p = 0.86). Mean VA at 6 months after Ahmed implantation was 0.35 ± 0.29 and 0.42 ± 0.33 log mean angle of resolution in the Ahmed only group and the combined group, respectively (p = 0.50). No significant differences in surgical success or adverse events were noted between the two groups. At 6 months, no significant differences in mean IOP, mean number of IOP-lowering medications, VA, surgical success, or adverse events were noted between Ahmed implantation alone or combined Ahmed and Retisert implantation in patients with uveitic glaucoma.

  9. Assessment of auditory cortical function in cochlear implant patients using 15O PET

    International Nuclear Information System (INIS)

    Young, J.P.; O'Sullivan, B.T.; Gibson, W.P.; Sefton, A.E.; Mitchell, T.E.; Sanli, H.; Cervantes, R.; Withall, A.; Royal Prince Alfred Hospital, Sydney,

    1998-01-01

    Full text: Cochlear implantation has been an extraordinarily successful method of restoring hearing and the potential for full language development in pre-lingually and post-lingually deaf individuals (Gibson 1996). Post-lingually deaf patients, who develop their hearing loss later in life, respond best to cochlear implantation within the first few years of their deafness, but are less responsive to implantation after several years of deafness (Gibson 1996). In pre-lingually deaf children, cochlear implantation is most effect in allowing the full development language skills when performed within a critical period, in the first 8 years of life. These clinical observations suggest considerable neural plasticity of the human auditory cortex in acquiring and retaining language skills (Gibson 1996, Buchwald 1990). Currently, electrocochleography is used to determine the integrity of the auditory pathways to the auditory cortex. However, the functional integrity of the auditory cortex cannot be determined by this method. We have defined the extent of activation of the auditory cortex and auditory association cortex in 6 normal controls and 6 cochlear implant patients using 15 O PET functional brain imaging methods. Preliminary results have indicated the potential clinical utility of 15 O PET cortical mapping in the pre-surgical assessment and post-surgical follow up of cochlear implant patients. Copyright (1998) Australian Neuroscience Society

  10. Immunological Response to Biodegradable Magnesium Implants

    Science.gov (United States)

    Pichler, Karin; Fischerauer, Stefan; Ferlic, Peter; Martinelli, Elisabeth; Brezinsek, Hans-Peter; Uggowitzer, Peter J.; Löffler, Jörg F.; Weinberg, Annelie-Martina

    2014-04-01

    The use of biodegradable magnesium implants in pediatric trauma surgery would render surgical interventions for implant removal after tissue healing unnecessary, thereby preventing stress to the children and reducing therapy costs. In this study, we report on the immunological response to biodegradable magnesium implants—as an important aspect in evaluating biocompatibility—tested in a growing rat model. The focus of this study was to investigate the response of the innate immune system to either fast or slow degrading magnesium pins, which were implanted into the femoral bones of 5-week-old rats. The main alloying element of the fast-degrading alloy (ZX50) was Zn, while it was Y in the slow-degrading implant (WZ21). Our results demonstrate that degrading magnesium implants beneficially influence the immune system, especially in the first postoperative weeks but also during tissue healing and early bone remodeling. However, rodents with WZ21 pins showed a slightly decreased phagocytic ability during bone remodeling when the degradation rate reached its maximum. This may be due to the high release rate of the rare earth-element yttrium, which is potentially toxic. From our results we conclude that magnesium implants have a beneficial effect on the innate immune system but that there are some concerns regarding the use of yttrium-alloyed magnesium implants, especially in pediatric patients.

  11. Prefabricated fibula free flap with dental implants for mandibular reconstruction.

    Science.gov (United States)

    Pauchet, D; Pigot, J-L; Chabolle, F; Bach, C-A

    2018-03-02

    Free fibula transplant is routinely used for mandibular reconstruction in head and neck cancer. Dental rehabilitation, the objective of mandibular reconstruction, requires the use of dental implants as supports for fixed or removable dentures. Positioning of fibular bone grafts and implants determines implant osseointegration and the possibilities of dental rehabilitation. Prefabrication of a fibula free flap with dental implants prior to harvesting as a free flap can promote implant osseointegration. The position of the implants must then be precisely planned. Virtual surgery and computer-assisted design and prefabrication techniques are used to plan the reconstruction and then reproduce this planning by means of tailored fibula and mandible cutting guides, thereby ensuring correct positioning of fibular bone fragments and implants. The prefabricated fibula free flap technique requires two surgical procedures (prefabrication and flap transfer) and precise preoperative planning. Prefabricated fibula free flap with dental implants, by improving the quality of osseointegration of the implants before flap transfer, extends the possibilities of prosthetic rehabilitation in complex secondary mandibular reconstructions. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  12. United Kingdom national paediatric bilateral cochlear implant audit: preliminary results.

    Science.gov (United States)

    Cullington, Helen; Bele, Devyanee; Brinton, Julie; Lutman, Mark

    2013-11-01

    Prior to 2009, United Kingdom (UK) public funding was mainly only available for children to receive unilateral cochlear implants. In 2009, the National Institute for Health and Care Excellence published guidance for cochlear implantation following their review. According to these guidelines, all suitable children are eligible to have simultaneous bilateral cochlear implants or a sequential bilateral cochlear implant if they had received the first before the guidelines were published. Fifteen UK cochlear implant centres formed a consortium to carry out a multi-centre audit. The audit involves collecting data from simultaneously and sequentially implanted children at four intervals: before bilateral cochlear implants or before the sequential implant, 1, 2, and 3 years after bilateral implants. The measures include localization, speech recognition in quiet and background noise, speech production, listening, vocabulary, parental perception, quality of life, and surgical data including complications. The audit has now passed the 2-year point, and data have been received on 850 children. This article provides a first view of some data received up until March 2012.

  13. Hearing Preservation Outcomes With a Mid-Scala Electrode in Cochlear Implantation.

    Science.gov (United States)

    Hunter, Jacob B; Gifford, René H; Wanna, George B; Labadie, Robert F; Bennett, Marc L; Haynes, David S; Rivas, Alejandro

    2016-03-01

    To evaluate hearing preservation (HP) outcomes in adult cochlear implant recipients with a mid-scala electrode. Tertiary academic center. Adult patients implanted with a mid-scala electrode between May 2013 and July 2015. Cochlear implantation. Age, sex, surgical approach, residual hearing changes post cochlear implantation, HP rates using different published classifications, and speech perception scores. Fifty ears for 47 patients (mean age, 58.2 yr; range, 23-86) were implanted with the electrode. Recognizing that not all patients were true HP candidates and/or underwent generally accepted HP surgical techniques, 39 ears had preoperative low-frequency hearing (audiometric threshold ≤ 85dB HL at 250Hz), 24 preserved acoustic hearing postoperatively (75.0%). Patients who had preserved acoustic hearing were implanted via round window (N = 18), extended round window (N = 4), or via cochleostomy (N = 2) approaches. Mean threshold elevation for low-frequency pure-tone average (125, 250, and 500  Hz) was 20.2  dB after surgery. 43.8% of patients had aidable low-frequency hearing at activation, 30.0% at 6-months postoperatively, and 30.8% 1-year postopera tively. Using a formula outlined by Skarzynski and colleagues, at 6-months postoperatively, 15.0% of patients had complete HP, whereas 40.0% had partial HP. At 1-year, these percentages decreased to 0% and 38.5%, respectively. Age, type of approach, and perioperative steroid use were not correlated with HP outcomes at activation and 6-months postoperatively (p > 0.05). The mid-scala electrode evaluated allows preservation of low-frequency hearing in patients undergoing cochlear implantation at rates and degrees of preservation close to other reports in the cochlear implant literature.

  14. Toward the Development of Virtual Surgical Tools to Aid Orthopaedic FE Analyses

    Directory of Open Access Journals (Sweden)

    Srinivas C. Tadepalli

    2010-01-01

    Full Text Available Computational models of joint anatomy and function provide a means for biomechanists, physicians, and physical therapists to understand the effects of repetitive motion, acute injury, and degenerative diseases. Finite element models, for example, may be used to predict the outcome of a surgical intervention or to improve the design of prosthetic implants. Countless models have been developed over the years to address a myriad of orthopaedic procedures. Unfortunately, few studies have incorporated patient-specific models. Historically, baseline anatomic models have been used due to the demands associated with model development. Moreover, surgical simulations impose additional modeling challenges. Current meshing practices do not readily accommodate the inclusion of implants. Our goal is to develop a suite of tools (virtual instruments and guides which enable surgical procedures to be readily simulated and to facilitate the development of all-hexahedral finite element mesh definitions.

  15. Reading the small print - labelling recommendations for orthopaedic implants.

    Science.gov (United States)

    Haene, Roger A; Sandhu, Ranbir S; Baxandall, Richard

    2009-11-01

    There exist, currently, no clear guidelines regarding standards for surgical implant labelling. Dimensions of the laminar flow canopies in orthopaedic use fixes the distance at which implant labels can be read. Mistakes when reading the label on an implant box can pose health risks for patients, and financial consequences for medical institutions. Using scientifically validated tools such as the Snellen Chart Formula, a theoretical minimum standard for text on implant labels was reached. This theoretical standard was then tested under real operating conditions. After discovering a minimum practical standard for implant labels, the authors then audited current labels in use on a wide range of orthopaedic implant packages. Furthermore, other non-text-related labelling problems were also noted. There is a definite minimum standard which should be observed when implant labels are manufactured. Implants in current use bear labels on the packaging that are of an insufficient standard to ensure patient safety in theatre. The authors have established text parameters that will increase the legibility of implant labels. In the interests of improving risk management in theatre, therefore, the authors propose a standard for orthopaedic implant labelling, and believe this will provide a useful foundation for further discussion between the orthopaedic community and implant manufacturers.

  16. Recent advances in the design of drug-loaded polymeric implants for the treatment of solid tumors.

    Science.gov (United States)

    Wadee, Ameena; Pillay, Viness; Choonara, Yahya E; du Toit, Lisa C; Penny, Clement; Ndesendo, Valence M K; Kumar, Pradeep; Murphy, Caragh S

    2011-10-01

    The effective treatment of solid tumors continues to be a great challenge to clinicians, despite the development of novel drugs. In order to improve the clinical efficacy of existing chemotherapeutic agents, researchers have considered the possibility of site-specific solid tumor treatment. The greatest advantage of localized delivery is the significantly fewer side effects experienced by patients. Recently, in situ forming implants have attracted considerable interest. These polymeric systems are injected as solutions into tumor sites and the injected solution forms an implant as a result of local environmental stimuli and hence removes the need for surgical implantation. This review summarizes the attempts that have been made to date in the development of polymeric implants for the treatment of solid tumors. Both in situ forming implants and preformed implants, fabricated using natural and synthetic polymers, are described. In addition, the peri- or intra-tumoral delivery of chemotherapeutic agents based on implants inserted surgically into the affected region is also discussed along with a short coverage of implants having an undesirable initial burst release effect. Although these implants have been shown to improve the treatment of various solid tumors, the ideal implant that is able to deliver high doses of chemotherapeutics to the tumor site, over prolonged periods with relatively few side effects on normal tissue, is yet to be formulated.

  17. Determining factors for implant referral rates.

    Science.gov (United States)

    Levin, Roger P

    2002-01-01

    The research findings indicate that the field of implant dentistry will only grow at a moderately low level unless certain changes are made. Findings indicated that the effort by the implant companies has been nothing short of dramatic, and yet almost 60% of restorative doctors do not participate annually in any implant case. There was no clear indication that younger restorative doctors will significantly increase the number of implant referrals, as their overall implant education has not dramatically differed from those dentists who graduated in earlier years. Once the research was completed, it became obvious to Levin Group that the driving force behind implant referral growth will be implant surgeons, because of their one-to-one relationship with restorative doctors. The Levin Group Implant Management and Marketing Consulting Program is based on approaching restorative doctors in several different levels, starting with awareness all the way through to case facilitation and long-term tracking and communication. Finally, a continuing marketing/education effort needs to be consistently in place with effective materials, not only to create a high level of awareness, but also to motivate restorative doctors to refer cases and then work through the case with the implant surgeon to a satisfactory completion for the restorative doctor, implant surgeon, and patient. While the surgical insertion of implants may seem to carry a high-profit margin relative to the restoration of implants, the truth is that the restoration of implants usually provides a 40% higher profit margin for the restorative doctor than traditional dental services. One of the key issues is that referring doctors have not necessarily learned how to set fees and present cases with regard to implant dentistry. The key factor here is to ensure that the patient understands that implant services involve higher fees than traditional services, because of the necessarily higher levels of experience, education

  18. Biocorrosion of magnesium alloys: a new principle in cardiovascular implant technology?

    Science.gov (United States)

    Heublein, B; Rohde, R; Kaese, V; Niemeyer, M; Hartung, W; Haverich, A

    2003-06-01

    To develop and test a new concept of the degradation kinetics of newly developed coronary stents consisting of magnesium alloys. Design of a coronary stent prototype consisting of the non-commercial magnesium based alloy AE21 (containing 2% aluminium and 1% rare earths) with an expected 50% loss of mass within six months. Eleven domestic pigs underwent coronary implantation of 20 stents (overstretch injury). No stent caused major problems during implantation or showed signs of initial breakage in the histological evaluation. There were no thromboembolic events. Quantitative angiography at follow up showed a significant (p biocorrosion seem to be a realistic alternative to permanent implants.

  19. Modified endoscopic medial maxillectomy for zygomatic implant salvage.

    Science.gov (United States)

    Schwartz, Joseph S; Tajudeen, Bobby A; Adappa, Nithin D; Palmer, James N

    2016-01-01

    Odontogenic chronic rhinosinusitis (CRS) is an epidemiologically important disease process due, in part, to the increasingly commonplace use of dental restorative procedures such as zygomatic implantation. Traditional management of this clinical entity typically entails extraction of the infected hardware via an open or endoscopic approach. We describe a novel management strategy of odontogenic CRS following bilateral zygomatic implantation for oral rehabilitation that we surgically salvaged via a modified endoscopic medial maxillectomy. We describe the presentation and management of a case of metachronous development of bilateral CRS subsequent to zygomatic implantation. The patient's postoperative course was characterized by marked endoscopic, radiologic, and symptomatic improvement as measured by the 22-item Sino-Nasal Outcome Test. We describe a novel treatment strategy for the management of odontogenic sinusitis resulting from erroneous zygomatic implant placement. Modified endoscopic medial maxillectomy in this clinical context facilitates mucosal normalization of the affected sinus, while permitting preservation of oral function through salvage of the displaced implant.

  20. Various Techniques to Increase Keratinized Tissue for Implant Supported Overdentures: Retrospective Case Series

    Directory of Open Access Journals (Sweden)

    Ahmed Elkhaweldi

    2015-01-01

    Full Text Available Purpose. The purpose of this retrospective case series is to describe and compare different surgical techniques that can be utilized to augment the keratinized soft tissue around implant-supported overdentures. Materials and Methods. The data set was extracted as deidentified information from the routine treatment of patients at the Ashman Department of Periodontology and Implant Dentistry at New York University College of Dentistry. Eight edentulous patients were selected to be included in this study. Patients were treated for lack of keratinized tissue prior to implant placement, during the second stage surgery, and after delivery of the final prosthesis. Results. All 8 patients in this study were wearing a complete maxillary and/or mandibular denture for at least a year before the time of the surgery. One of the following surgical techniques was utilized to increase the amount of keratinized tissue: apically positioned flap (APF, pedicle graft (PG, connective tissue graft (CTG, or free gingival graft (FGG. Conclusions. The amount of keratinized tissue should be taken into consideration when planning for implant-supported overdentures. The apical repositioning flap is an effective approach to increase the width of keratinized tissue prior to the implant placement.

  1. ASPS clinical practice guideline summary on breast reconstruction with expanders and implants.

    Science.gov (United States)

    Alderman, Amy; Gutowski, Karol; Ahuja, Amy; Gray, Diedra

    2014-10-01

    After reading this article, participants should be able to: 1. Understand the evidence regarding the timing of expander/implant breast reconstruction in the setting of radiation therapy. 2. Discuss the implications of a patient's risk factors for possible outcomes and complications of expander/implant breast reconstruction. 3. Implement proper prophylactic antibiotic protocols. 4. Use the guidelines to improve their own clinical outcomes and reduce complications. In March of 2013, the Executive Committee of the American Society of Plastic Surgeons approved an evidence-based guideline on breast reconstruction with expanders and implants, as developed by a guideline-specific work group commissioned by the society's Health Policy Committee. The guideline addresses ten clinical questions: patient education, immediate versus delayed reconstruction, risk factors, radiation therapy, chemotherapy, hormonal therapy, antibiotic prophylaxis, acellular dermal matrix, monitoring for cancer recurrence, and oncologic outcomes associated with implant-based reconstruction. The evidence indicates that patients undergoing mastectomy should be offered a preoperative referral to a plastic surgeon. Evidence varies regarding the association between postoperative complications and timing of postmastectomy expander/implant breast reconstruction. Evidence is limited regarding the optimal timing of expand/implant reconstruction in the setting of radiation therapy but suggests that irradiation to the expander or implant is associated with an increased risk of postoperative complications. Evidence also varies regarding the association between acellular dermal matrix and surgical complications in the setting of postmastectomy expander/implant reconstruction. Data support the use of an appropriate preoperative antibiotic, but antibiotics should be discontinued within 24 hours of the procedure, unless a surgical drain is present. Furthermore, postmastectomy expander/implant breast reconstruction

  2. Cochlear implant revision surgeries in children.

    Science.gov (United States)

    Amaral, Maria Stella Arantes do; Reis, Ana Cláudia Mirândola B; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2018-02-16

    The surgery during which the cochlear implant internal device is implanted is not entirely free of risks and may produce problems that will require revision surgeries. To verify the indications for cochlear implantation revision surgery for the cochlear implant internal device, its effectiveness and its correlation with certain variables related to language and hearing. A retrospective study of patients under 18 years submitted to cochlear implant Surgery from 2004 to 2015 in a public hospital in Brazil. Data collected were: age at the time of implantation, gender, etiology of the hearing loss, audiological and oral language characteristics of each patient before and after Cochlear Implant surgery and any need for surgical revision and the reason for it. Two hundred and sixty-five surgeries were performed in 236 patients. Eight patients received a bilateral cochlear implant and 10 patients required revision surgery. Thirty-two surgeries were necessary for these 10 children (1 bilateral cochlear implant), of which 21 were revision surgeries. In 2 children, cochlear implant removal was necessary, without reimplantation, one with cochlear malformation due to incomplete partition type I and another due to trauma. With respect to the cause for revision surgery, of the 8 children who were successfully reimplanted, four had cochlear calcification following meningitis, one followed trauma, one exhibited a facial nerve malformation, one experienced a failure of the cochlear implant internal device and one revision surgery was necessary because the electrode was twisted. The incidence of the cochlear implant revision surgery was 4.23%. The period following the revision surgeries revealed an improvement in the subject's hearing and language performance, indicating that these surgeries are valid in most cases. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  3. Histological assessment of titanium and polypropylene fiber mesh implantation with and without fibrin tissue glue.

    NARCIS (Netherlands)

    Hallers, E.J.O. ten; Jansen, J.A.; Marres, H.A.M.; Rakhorst, G.; Verkerke, G.J.

    2007-01-01

    Polypropylene (PP) and titanium (Ti) meshes are well-known surgical implants that provoke a relative low foreign body reaction. Firm stabilization of the implant is important to prevent migration and subsequent failure of the operation. Fibrin tissue glues are commercially available adhesives and

  4. Histological assessment of titanium and polypropylene fiber mesh implantation with and without fibrin tissue glue

    NARCIS (Netherlands)

    ten Hallers, E.J. Olivier; Jansen, John A.; Marres, Henri A.M.; Rakhorst, Gerhard; Verkerke, Gijsbertus Jacob

    2007-01-01

    Polypropylene (PP) and titanium (Ti) meshes are well-known surgical implants that provoke a relative low foreign body reaction. Firm stabilization of the implant is important to prevent migration and subsequent failure of the operation. Fibrin tissue glues are commercially available adhesives and

  5. Histological assessment of titanium and polypropylene fiber mesh implantation with and without fibrin tissue glue

    NARCIS (Netherlands)

    ten Hallers, E. J. Olivier; Jansen, John A.; Marres, Henri A. M.; Rakhorst, Gerhard; Verkerke, Gijsbertus J.

    Polypropylene (PP) and titanium (Ti) meshes are well-known surgical implants that provoke a relative low foreign body reaction. Firm stabilization of the implant is important to prevent migration and subsequent failure of the operation. Fibrin tissue glues are commercially available adhesives and

  6. Qualitative and quantitative observations of bone tissue reactions to anodised implants.

    Science.gov (United States)

    Sul, Young-Taeg; Johansson, Carina B; Röser, Kerstin; Albrektsson, Tomas

    2002-04-01

    Research projects focusing on biomaterials related factors; the bulk implant material, the macro-design of the implant and the microsurface roughness are routinely being conducted at our laboratories. In this study, we have investigated the bone tissue reactions to turned commercially pure (c.p.) titanium implants with various thicknesses of the oxide films after 6 weeks of insertion in rabbit bone. The control c.p. titanium implants had an oxide thickness of 17-200 nm while the test implants revealed an oxide thickness between 600 and 1000 nm. Routine histological investigations of the tissue reactions around the implants and enzyme histochemical detections of alkaline and acid phosphatase activities demonstrated similar findings around both the control and test implants. In general, the histomorphometrical parameters (bone to implant contact and newly formed bone) revealed significant quantitative differences between the control and test implants. The test implants demonstrated a greater bone response histomorphometrically than control implants and the osteoconductivity was more pronounced around the test implant surfaces. The parameters that differed between the implant surfaces, i.e. the oxide thickness, the pore size distribution, the porosity and the crystallinity of the surface oxides may represent factors that have an influence on the histomorphometrical results indicated by a stronger bone tissue response to the test implant surfaces, with an oxide thickness of more than 600 nm.

  7. Minimally Invasive Epicardial Pacemaker Implantation in Neonates with Congenital Heart Block.

    Science.gov (United States)

    Costa, Roberto; Silva, Katia Regina da; Martinelli Filho, Martino; Carrillo, Roger

    2017-10-01

    Few studies have characterized the surgical outcomes following epicardial pacemaker implantation in neonates with congenital complete atrioventricular block (CCAVB). This study sought to assess the long-term outcomes of a minimally invasive epicardial approach using a subxiphoid access for pacemaker implantation in neonates. Between July 2002 and February 2015, 16 consecutive neonates underwent epicardial pacemaker implantation due to CCAVB. Among these, 12 (75.0%) had congenital heart defects associated with CCAVB. The patients had a mean age of 4.7 ± 5.3 days and nine (56.3%) were female. Bipolar steroid-eluting epicardial leads were implanted in all patients through a minimally invasive subxiphoid approach and fixed on the diaphragmatic ventricular surface. The pulse generator was placed in an epigastric submuscular position. All procedures were successful, with no perioperative complications or early deaths. Mean operating time was 90.2 ± 16.8 minutes. None of the patients displayed pacing or sensing dysfunction, and all parameters remained stable throughout the follow-up period of 4.1 ± 3.9 years. Three children underwent pulse generator replacement due to normal battery depletion at 4.0, 7.2, and 9.0 years of age without the need of ventricular lead replacement. There were two deaths at 12 and 325 days after pacemaker implantation due to bleeding from thrombolytic use and progressive refractory heart failure, respectively. Epicardial pacemaker implantation through a subxiphoid approach in neonates with CCAVB is technically feasible and associated with excellent surgical outcomes and pacing lead longevity.

  8. The use of virtual surgical planning and navigation in the treatment of orbital trauma

    Directory of Open Access Journals (Sweden)

    Alan Scott Herford

    2017-02-01

    Full Text Available Virtual surgical planning (VSP has recently been introduced in craniomaxillofacial surgery with the goal of improving efficiency and precision for complex surgical operations. Among many indications, VSP can also be applied for the treatment of congenital and acquired craniofacial defects, including orbital fractures. VSP permits the surgeon to visualize the complex anatomy of craniofacial region, showing the relationship between bone and neurovascular structures. It can be used to design and print using three-dimensional (3D printing technology and customized surgical models. Additionally, intraoperative navigation may be useful as an aid in performing the surgery. Navigation is useful for both the surgical dissection as well as to confirm the placement of the implant. Navigation has been found to be especially useful for orbit and sinus surgery. The present paper reports a case describing the use of VSP and computerized navigation for the reconstruction of a large orbital floor defect with a custom implant.

  9. Early Clinical Results of a Novel Ab Interno Gel Stent for the Surgical Treatment of Open-angle Glaucoma.

    Science.gov (United States)

    Sheybani, Arsham; Dick, H Burkhard; Ahmed, Iqbal I K

    2016-07-01

    To evaluate the intraocular pressure (IOP) lowering effect of the XEN140 microfistula gel stent implant for the surgical treatment of open-angle glaucoma. Forty-nine eyes of 49 patients with an IOP>18 mm Hg and ≤35 mm Hg were studied in a prospective nonrandomized multicenter cohort trial of the surgical implantation of the XEN140 implant in patients with open-angle glaucoma. Complete success was defined as a postoperative IOP≤18 mm Hg with ≥20% reduction in IOP at 12 months without any glaucoma medications. Failure was defined as vision loss of light perceptions vision or worse, need for additional glaucoma surgery, or glaucoma.

  10. 3D Printing Guide Implant Placement: A Case Report

    Directory of Open Access Journals (Sweden)

    Vlahović Zoran

    2017-03-01

    Full Text Available Background: Cone Beam Computer Tomography (CBCT is representing a new concept of radiological diagnostics and its application occupies a special place in implantology. Today, preoperative planning, and quantitative and qualitative jaw bone analysis cannot be done without the use of these techniques. The latest in a series of achievements in this field is a method of making a guide for implant using a 3D printing technique. This way pre implantology planning reduces the chance of surgical complications to a minimum and allows installation of dental implants in the most optimal position for future prosthetic work. Aim: To show benefits of guide implantation in clinical practice.

  11. [Role of endo-osseus implant in odonto-oral rehabilitation].

    Science.gov (United States)

    Vanhakendover, S

    2003-01-01

    Dental implants have critically changed the restorative procedures available to edentulous patients. Biocompatible materials, precise surgical techniques and improved instrumentation give well trained practicioners various opportunities to achieve successful treatments. The necessity of combining full expertise in surgery and rational prosthetic planning with comprehensive occlusal management is emphasized. Recent advances in periodontal treatment of osseous and soft tissue defects, new grafting techniques and surgical approaches have dramatically enlarged the scope of oral implantology.

  12. The immediate insertion, loading and provisional prosthetic restoration of dental implants.

    Science.gov (United States)

    Sârbu, I

    2008-01-01

    The immediate insertion and loading of dental implants although used in the past as an alternative method for the surgical phase of the dental implant treatment is today becoming more and more popular due to its immediate and spectacular results. With information on bone density and a careful patient selection, this method has increased chances of success. Its main advantage is the high degree of patient comfort with a great aesthetic effect. This article presents the theoretical and practical technique used on two clinical cases of dental implantation and their outcome.

  13. Electrospun nanofibrous scaffolds increase the efficacy of stem cell-mediated therapy of surgically resected glioblastoma

    Science.gov (United States)

    Bagó, Juli R.; Pegna, Guillaume J.; Okolie, Onyi; Mohiti-Asli, Mahsa; Loboa, Elizabeth G.; Hingtgen, Shawn D.

    2017-01-01

    Engineered stem cell (SC)-based therapy holds enormous promise for treating the incurable brain cancer glioblastoma (GBM). Retaining the cytotoxic SCs in the surgical cavity after GBM resection is one of the greatest challenges to this approach. Here, we describe a biocompatible electrospun nanofibrous scaffold (bENS) implant capable of delivering and retaining tumor-homing cytotoxic stem cells that suppress recurrence of post-surgical GBM. As a new approach to GBM therapy, we created poly(l-lactic acid) (PLA) bENS bearing drug-releasing human mesenchymal stem cells (hMSCs). We discovered that bENS-based implant increased hMSC retention in the surgical cavity 5-fold and prolonged persistence 3-fold compared to standard direct injection using our mouse model of GBM surgical resection/recurrence. Time-lapse imaging showed cytotoxic hMSC/bENS treatment killed co-cultured human GBM cells, and allowed hMSCs to rapidly migrate off the scaffolds as they homed to GBMs. In vivo, bENS loaded with hMSCs releasing the anti-tumor protein TRAIL (bENSsTR) reduced the volume of established GBM xenografts 3-fold. Mimicking clinical GBM patient therapy, lining the post-operative GBM surgical cavity with bENSsTR implants inhibited the re-growth of residual GBM foci 2.3-fold and prolonged post-surgical median survival from 13.5 to 31 days in mice. These results suggest that nanofibrous-based SC therapies could be an innovative new approach to improve the outcomes of patients suffering from terminal brain cancer. PMID:27016620

  14. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome.

    Science.gov (United States)

    Koyama, Hajime; Kashio, Akinori; Sakata, Aki; Tsutsumiuchi, Katsuhiro; Matsumoto, Yu; Karino, Shotaro; Kakigi, Akinobu; Iwasaki, Shinichi; Yamasoba, Tatsuya

    2016-01-01

    Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months). Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome.

  15. The Hearing Outcomes of Cochlear Implantation in Waardenburg Syndrome

    Directory of Open Access Journals (Sweden)

    Hajime Koyama

    2016-01-01

    Full Text Available Objectives. This study aimed to determine the feasibility of cochlear implantation for sensorineural hearing loss in patients with Waardenburg syndrome. Method. A retrospective chart review was performed on patients who underwent cochlear implantation at the University of Tokyo Hospital. Clinical classification, genetic mutation, clinical course, preoperative hearing threshold, high-resolution computed tomography of the temporal bone, and postoperative hearing outcome were assessed. Result. Five children with Waardenburg syndrome underwent cochlear implantation. The average age at implantation was 2 years 11 months (ranging from 1 year 9 months to 6 years 3 months. Four patients had congenital profound hearing loss and one patient had progressive hearing loss. Two patients had an inner ear malformation of cochlear incomplete partition type 2. No surgical complication or difficulty was seen in any patient. All patients showed good hearing outcome postoperatively. Conclusion. Cochlear implantation could be a good treatment option for Waardenburg syndrome.

  16. Percutaneous implantation of the CoreValve aortic valve prosthesis in patients at high risk or rejected for surgical valve replacement: Clinical evaluation and feasibility of the procedure in the first 30 patients in the AMC-UvA

    NARCIS (Netherlands)

    Baan, J.; Yong, Z. Y.; Koch, K. T.; Henriques, J. P. S.; Bouma, B. J.; de Hert, S. G.; van der Meulen, J.; Tijssen, J. G. P.; Piek, J. J.; de Mol, B. A. J. M.

    2010-01-01

    Objective. To report the feasibility, safety and efficacy of percutaneous aortic valve implantation (PAVI) with the CoreValve self-expanding aortic valve bioprosthesis in elderly patients with aortic valve stenosis who are rejected for surgery or have a high surgical risk.Methods. PAVI using the

  17. Ultraviolet radiation as disinfection for fish surgical tools

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Ricardo W.; Markillie, Lye Meng; Colotelo, Alison HA; Geist, David R.; Gay, Marybeth E.; Woodley, Christa M.; Eppard, M. B.; Brown, Richard S.

    2013-04-04

    Telemetry is frequently used to examine the behavior of fish, and the transmitters used are normally surgically implanted into the coelomic cavity of fish. Implantation requires the use of surgical tools such as scalpels, forceps, needle holders, and sutures. When fish are implanted consecutively, as in large telemetry studies, it is common for surgical tools to be sterilized or, at minimum, disinfected between each use so that pathogens that may be present are not spread among fish. To determine the efficacy for this application, ultraviolet (UV) radiation was used to disinfect surgical tools exposed to one of four aquatic organisms that typically lead to negative health issues for salmonids. These organisms included Aeromonas salmonicida, Flavobacterium psychrophilum, Renibacterium salmoninarum, and Saprolegnia parasitica, causative agents of furunculosis, coldwater disease, bacterial kidney disease, and saprolegniasis (water mold), respectively. Four experiments were conducted to address the question of UV efficacy. In the first experiment, forceps were exposed to the three bacteria at three varying concentrations. After exposure to the bacterial culture, tools were placed into a mobile Millipore UV sterilization apparatus. The tools were then exposed for three different time periods – 2, 5, or 15 min. UV radiation exposures at all durations were effective at killing all three bacteria on forceps at the highest bacteria concentrations. In the second experiment, stab scalpels, sutures, and needle holders were exposed to A. salmonicida using the same methodology as used in Experiment 1. UV radiation exposure at 5 and 15 min was effective at killing A. salmonicida on stab scalpels and sutures but not needle holders. In the third experiment, S. parasitica, a water mold, was tested using an agar plate method and forceps-pinch method. UV radiation was effective at killing the water mold at all three exposure durations. Collectively, this study shows that UV

  18. Minimally invasive piezosurgery for a safe placement of blade dental implants in jaws with severe bone loss

    Directory of Open Access Journals (Sweden)

    F. Rossi

    2014-10-01

    Full Text Available Aim :Severe atrophies of edentulous jaws require major reconstructive bone surgery in order to allow the placement of root-form implants with standard diameter. These bone augmentation techniques represent the best option reported in the literature, but they are often rejected by patients because of their high economic and biological costs in addition to the possibility of failure in the short and/or long term. In the maxilla regenerative methods (onlay, inlay, and distraction have high success rates, whereas in the mandible, especially in the distal atrophic area, they are not so predictable. In such situations an alternative technique for fixed prosthethic rebilitation is the insertion of platform blade implants, which have their elective indication for atrophic bone ridges with reduced width, owing to their reduced thickness. The aim of this study is to assess the effectiveness of the use of piezoelectric ultrasonic handpieces, in order to simplify the placement of blade implants, making it safer and less traumatic than with conventional surgical procedures. Materials and methods: Platform blade implants are extension implant functionally and aesthetically reliable, even if they require a more difficult surgical technique compared with the one currently in use for screw implants. A minimally invasive procedure by means of piezosurgery that was performed on 142 subjects is presented and a case is reported which highlights the successful results. Results: and conclusion The use of piezoelectric ultrasonic handpieces simplifies the surgical procedure for the placement of blade implant, making it safer and less traumatic.

  19. Imaging of implants on chest radiographs: a radiological perspective

    International Nuclear Information System (INIS)

    Burney, K.; Thayur, N.; Husain, S.A.; Martin, R.P.; Wilde, P.

    2007-01-01

    Endovascular and percutaneous techniques have emerged as alternatives to surgical management in the treatment for a wide range of congenital and acquired cardiac, non-vascular and vascular conditions. Consequently, there has been an increasing use of implants such as closure devices, vascular stents (coronary, aortic, pulmonary and superior vena cava) and non-vascular stents like oesophageal and tracheo-bronchial stents. A large number of percutaneously sited implants are used for treating congenital cardiac anomalies such as atrial septal defects (ASD), ventricular septal defects (VSD), and patent ductus arteriosus (PDA). These implants take many shapes and forms. The aim of this review is to demonstrate the radiographic appearances of the various types of cardiovascular, bronchial and oesophageal implants that are visible on plain films. A brief outline of the aims and indications of various implant procedures, the general appearance of the commonest types of implants, and the radiological procedures are discussed. All radiologists are likely to come across implanted devices in plain film reporting. Imaging can be useful in identifying the device, assessing the position, integrity, and for the identification of complications related directly to the implant

  20. Imaging of implants on chest radiographs: a radiological perspective

    Energy Technology Data Exchange (ETDEWEB)

    Burney, K [Department of Clinical Radiology, Bristol Royal Infirmary (United Kingdom); Thayur, N [Department of Clinical Radiology, Bristol Royal Infirmary (United Kingdom); Husain, S A [Department of Respiratory Medicine, Bristol Royal Infirmary (United Kingdom); Martin, R P [Department of Cardiology, Bristol Royal Hospital for Children, Bristol (United Kingdom); Wilde, P [Department of Clinical Radiology, Bristol Royal Infirmary (United Kingdom)

    2007-03-15

    Endovascular and percutaneous techniques have emerged as alternatives to surgical management in the treatment for a wide range of congenital and acquired cardiac, non-vascular and vascular conditions. Consequently, there has been an increasing use of implants such as closure devices, vascular stents (coronary, aortic, pulmonary and superior vena cava) and non-vascular stents like oesophageal and tracheo-bronchial stents. A large number of percutaneously sited implants are used for treating congenital cardiac anomalies such as atrial septal defects (ASD), ventricular septal defects (VSD), and patent ductus arteriosus (PDA). These implants take many shapes and forms. The aim of this review is to demonstrate the radiographic appearances of the various types of cardiovascular, bronchial and oesophageal implants that are visible on plain films. A brief outline of the aims and indications of various implant procedures, the general appearance of the commonest types of implants, and the radiological procedures are discussed. All radiologists are likely to come across implanted devices in plain film reporting. Imaging can be useful in identifying the device, assessing the position, integrity, and for the identification of complications related directly to the implant.

  1. Prosthetic Rehabilitation of a Patient with Mandibular Resection Prosthesis Using Mini Dental Implants (MDIs) – Case Report

    OpenAIRE

    Vojvodić, Denis; Čelebić, Asja; Mehulić, Ketij; Žabarović, Domagoj

    2012-01-01

    Physical disfigurement and functional impairments associated with facial trauma are a challenge to a prosthodontist, because even novel sophisticated surgical reconstructive techniques fail to provide adequate support for dental resection prosthesis. Therefore, different endosseous implants are often used as prosthesis-supporting elements. Manufacturers of dental implants have recently presented mini dental implants (MDIs) with diameter of only 1.8–2.4 mm. These implants allow very suitable p...

  2. Adjuvant Maneuvers for Residual Curvature Correction During Penile Prosthesis Implantation in Men with Peyronie's Disease.

    Science.gov (United States)

    Berookhim, Boback M; Karpman, Edward; Carrion, Rafael

    2015-11-01

    The surgical treatment of comorbid erectile dysfunction and Peyronie's disease has long included the implantation of an inflatable penile prosthesis as well as a number of adjuvant maneuvers to address residual curvature after prosthesis placement. To review the various surgical options for addressing curvature after prosthesis placement, with specific attention paid to an original article by Wilson et al. reporting on modeling over a penile prosthesis for the management of Peyronie's disease. A literature review was performed analyzing articles reporting the management of penile curvature in patients undergoing implantation of an inflatable penile prosthesis. Reported improvement in Peyronie's deformity as well as the complication rate associated with the various surgical techniques described. Modeling is a well-established treatment modality among patients with Peyronie's disease undergoing penile prosthesis implantation. A variety of other adjuvant maneuvers to address residual curvature when modeling alone is insufficient has been presented in the literature. Over 20 years of experience with modeling over a penile prosthesis have proven the efficacy and safety of this treatment option, providing the surgeon a simple initial step for the management of residual curvature after penile implantation which allows for the use of additional adjuvant maneuvers in those with significant deformities. © 2015 International Society for Sexual Medicine.

  3. Chronically implanted pressure sensors: challenges and state of the field.

    Science.gov (United States)

    Yu, Lawrence; Kim, Brian J; Meng, Ellis

    2014-10-31

    Several conditions and diseases are linked to the elevation or depression of internal pressures from a healthy, normal range, motivating the need for chronic implantable pressure sensors. A simple implantable pressure transduction system consists of a pressure-sensing element with a method to transmit the data to an external unit. The biological environment presents a host of engineering issues that must be considered for long term monitoring. Therefore, the design of such systems must carefully consider interactions between the implanted system and the body, including biocompatibility, surgical placement, and patient comfort. Here we review research developments on implantable sensors for chronic pressure monitoring within the body, focusing on general design requirements for implantable pressure sensors as well as specifications for different medical applications. We also discuss recent efforts to address biocompatibility, efficient telemetry, and drift management, and explore emerging trends.

  4. Quasi-static strength and fractography analysis of two dental implants manufactured by direct metal laser sintering.

    Science.gov (United States)

    Gehrke, Sergio Alexandre; Pérez-Díaz, Leticia; Dedavid, Berenice Anina

    2018-01-30

    New manufacturing methods was developed to improve the tissues integration with the titanium alloy pieces. The present in vitro study was to assess the resistance and fracture mode after applied a quasi-static compressive force on the two dental implants manufactured by direct metal laser sintering. Twenty dental implants manufactured by direct metal laser sintering, using titanium alloy (Ti-6Al-4V) granules in two designs (n = 10 per group): Conventional dental implant (group Imp1) two-piece implant design, where the surgical implant and prosthetic abutment are two separate components and, the one-piece implant (group Imp2), where the surgical implant and prosthetic abutment are one integral piece. All samples were subjected to quasi-static loading at a 30° angle to the implant axis in a universal testing machine. The mean fracture strengths were 1269.2 ± 128.8 N for the group Imp1 and, 1259.5 ± 115.1 N for the group Imp2, without statistical differences (P = .8722). In both groups, the fracture surface does not present crack between the compact core and the superficial (less dense and porous) part of the implants. Based on the measured resistance data for the two implant models manufactured by direct metal laser sintering tested in the present study, we can suggest that they have adequate capacity to withstand the masticatory loads. © 2018 Wiley Periodicals, Inc.

  5. Healthcare technology: physician collaboration in reducing the surgical cost.

    Science.gov (United States)

    Olson, Steven A; Obremskey, William T; Bozic, Kevin J

    2013-06-01

    The increasing cost of providing health care is a national concern. Healthcare spending related to providing hospital care is one of the primary drivers of healthcare spending in the United States. Adoption of advanced medical technologies accounts for the largest percentage of growth in healthcare spending in the United States when compared with other developed countries. Within the specialty of orthopaedic surgery, a variety of implants can result in similar outcomes for patients in several areas of clinical care. However, surgeons often do not know the cost of implants used in a specific procedure or how the use of an implant or technology affects the overall cost of the episode of care. The purposes of this study were (1) to describe physician-led processes for introduction of new surgical products and technologies; and (2) to inform physicians of potential cost savings of physician-led product contract negotiations and approval of new technology. We performed a detailed review of the steps taken by two centers that have implemented surgeon-led programs to demonstrate responsibility in technology acquisition and product procurement decision-making. Each program has developed a physician peer review process in technology and new product acquisition that has resulted in a substantial reduction in spending for the respective hospitals in regard to surgical implants. Implant costs have decreased between 3% and 38% using different negotiating strategies. At the same time, new product requests by physicians have been approved in greater than 90% of instances. Hospitals need physicians to be engaged and informed in discussions concerning current and new technology and products. Surgeons can provide leadership for these efforts to reduce the cost of high-quality care.

  6. Clinical efficacy analysis of Ahmed glaucoma valve implantation in neovascular glaucoma and influencing factors

    Science.gov (United States)

    He, Ye; Tian, Ying; Song, Weitao; Su, Ting; Jiang, Haibo; Xia, Xiaobo

    2017-01-01

    Abstract This study aimed to evaluate the efficacy of Ahmed glaucoma valve (AGV) implantation in treating neovascular glaucoma (NVG) and to analyze the factors influencing the surgical success rate. This is a retrospective review of 40 eyes of 40 NVG patients who underwent AGV implantation at Xiangya Hospital of Central South University, China, between January 2014 and December 2016. Pre- and postoperative intraocular pressure (IOP), visual acuity, surgical success rate, medications, and complications were observed. Surgical success criteria were defined as IOP ≤21 and >6 mm Hg with or without additional medications. Kaplan–Meier survival curves and Multivariate cox regression analysis were used to examine success rates and risk factors for surgical outcomes. The mean follow-up period was 8.88 ± 3.12 months (range: 3–17). IOP declined at each visit postoperatively and it was statistically significant (P < .001). An average of 3.55 ± 0.86 drugs was applied preoperatively, while an average of 0.64 ± 0.90 drugs was used postoperatively, with the difference being of statistical significance (P < .05). The complete surgical success rate of 3, 6, and 12 months after the operation was 85%, 75%, and 65%, respectively. Meanwhile, the qualified success rate of 3, 6, and 12 months after the operation was 85%, 80%, and 77.5%, respectively. The multivariate cox regression analysis showed that age (hazard ratio: 3.717, 7.246; 95% confidence interval: 1.149–12.048, 1.349–38.461; P = .028, .021) was influencing factors for complete success rate and qualified success rate among all NVG patients. Gender, previous operation history, primary disease, and preoperative IOP were found to be not significant. AGV implantation is an effective and safe surgical method to treat NVG. Age is an important factor influencing the surgical success rate. PMID:29049253

  7. The influence of micro and macro-geometry in term of bone-implant interface in two implant systems: an histomorphometrical study.

    Science.gov (United States)

    Rocci, A; Calcaterra, R; DI Girolamo, M; Rocci, M; Rocci, C; Baggi, L

    2015-01-01

    Many factors could affect the osseous healing of implants such as surface topography of biomaterial, the status of the bone/implant site, implant loading conditions, surgical technique and implant design. The aim of this study was to analyze the BIC of 2 different implants systems characterized by different micro and macrogeometry, that were placed in the posterior maxillary and mandibular jaws of humans, clinically unloaded and retrieved for histomorphometric analyses after 12 weeks. The patients were divided in two groups (Group I and II); group I was composed by 4 patients that each received in the posterior areas of mandible one type A implant [GTB-Plan1Health Amaro (UD) Italy] one type B implant (OsseoSpeed Astra Tech, Dentsply Molndal, Sweden). Group II was composed by 3 patients that each received in the posterior areas of jawsbone one type A implant [GTB-Plan1Health Amaro (UD) Italy] one type B implant (OsseoSpeed Astra Tech, Dentsply Molndal, Sweden). After 12 weeks of healing all the implants of both groups were harvested with the peri-implant bone tissues. Osseointegration process was evaluated throughout measurements of BIC. No statistical significance differences were found among the mean percentage of BIC of Group I - type A were 66,51% versus 49,96% in Group I - type B, as well as among the mean percentage of BIC of Group II - type A were 43.7% versus 60.02% in Group II - type B. Our results highlight that the mean percentage of BIC after 12 weeks from the implants placement without functional loading is not influenced by the composition of the implant surface.

  8. Osseointegration of dental implants in patients with and without radiotherapy

    International Nuclear Information System (INIS)

    Wagner, W.; Esser, E.; Ostkamp, K.

    1998-01-01

    Between 1987 and 1997, 275 dental implants were inserted in the mandibles of 63 patients with squamous cell carcinoma of the lower oropharyngeal level following a radical surgical procedure. Thirty-five of these patients had been preirradiated with a complete dose of 60 Gy. In a retrospective analysis we have reviewed the data of these patients for age, sex, localization of the implants, irradiation, interval of implantation and interval of the abutment operation. Thus far, the median follow-up time is 65 months. The 5-year success rate for all implants was 97.9%. We found that radiotherapy, age, sex, localization of implantation or the interval between the end of the tumor therapy and the time of implantation did not have any significant influence on osseointegration or loss of osseointegration. Only the time interval between implantation and the abutment operation was recorded to be of any great significance (p=0.0001). No augmentation in the osteoradionecrosis rate could be recorded after dental implantation (1.6%), which leads us to conclude that radiotherapy (60 Gy) in patients with head and neck cancers should not be regarded as a contraindication for dental implantation. (orig.)

  9. Antimicrobial and Antifouling Polymeric Agents for Surface Functionalization of Medical Implants.

    Science.gov (United States)

    Zeng, Qiang; Zhu, Yiwen; Yu, Bingran; Sun, Yujie; Ding, Xiaokang; Xu, Chen; Wu, Yu-Wei; Tang, Zhihui; Xu, Fu-Jian

    2018-05-09

    Combating implant-associated infections is an urgent demand due to the increasing numbers in surgical operations such as joint replacements and dental implantations. Surface functionalization of implantable medical devices with polymeric antimicrobial and antifouling agents is an efficient strategy to prevent bacterial fouling and associated infections. In this work, antimicrobial and antifouling branched polymeric agents (GPEG and GEG) were synthesized via ring-opening reaction involving gentamicin and ethylene glycol species. Due to their rich primary amine groups, they can be readily coated on the polydopamine-modified implant (such as titanium) surfaces. The resultant surface coatings of Ti-GPEG and Ti-GEG produce excellent in vitro antibacterial efficacy toward both Staphylococcus aureus and Escherichia coli, while Ti-GPEG exhibit better antifouling ability. Moreover, the infection model with S. aureus shows that implanted Ti-GPEG possessed excellent antibacterial and antifouling ability in vivo. This study would provide a promising strategy for the surface functionalization of implantable medical devices to prevent implant-associated infections.

  10. Findings from the experience with the punch technique for auditory osseointegrated implants: A retrospective single center comparative study.

    Science.gov (United States)

    Bonilla, Alfonso; Magri, Carlos; Juan, Eulalia

    To compare the punch technique and linear incision with soft tissue reduction for the placement of auditory osseointegrated implants (AOI) and analyze results of osseointegration obtained with the punch technique as measured with the Implant Stability Quotient (ISQ). Case review of 34 patients who received auditory osseointegrated implants between January 2010 and July 2015 and were divided into two groups according to the surgical technique: 18 with the punch technique (PT) and 16 with the linear incision technique (LI). Minimum follow-up was four months (mean: 24 months; range 4-64 months). Included in the analysis were patient profiles and records of the demographic data, surgical indications, surgical technique, implant placement, surgical time, intraoperative complications, as well as postsurgical complications (Holgers classification) and implant stability quotients (ISQ). Use of larger abutments was significantly greater in the PT group (PT, 10mm; LI, 6mm, p<0.001). The PT technique resulted in a shorter procedure than the LI (PT, 20min; LI, 45min, p<0.001). Holgers classification scores identified significantly fewer skin complications one week after surgery for the PT group; however, only small differences were seen between the two groups at the one- and three-month control visits. As shown for our cohort, the punch technique for surgical placement of AOI is faster and presents fewer immediate postoperative complications when compared to the linear incision technique. The clinical application of the ISQ is a useful, easy method to demonstrate the status of osseointegration and, thus, the stability of the device. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.

  11. Suprapubic cystostomy for the management of urethral injuries during penile prosthesis implantation.

    Science.gov (United States)

    Anele, Uzoma A; Le, Brian V; Burnett, Arthur L

    2014-12-01

    Urethral injury is an uncommon surgical complication of penile prosthesis (PP) surgery. Conventional dogma requires abortion of the procedure if the adjacent corporal body is involved or delayed implantation to avert device infection associated with urinary extravasation. Besides the setback of the aborted surgery, this management approach also presents the possible difficulty of encountering corporal fibrosis at the time of reoperation. We report an approach using primary urethral repair and temporary suprapubic cystostomy for the management of incidental urethral injuries in a cohort of patients allowing for successful completion of unaborted PP implantation. We performed a retrospective analysis of all patients receiving PPs from 1990 to 2014 in which incidental urethral injuries were repaired and PP implantation was completed with suprapubic cystostomy (suprapubic tube [SPT] insertion). After allowing for urethral healing and urinary diversion via SPT for 4-8 weeks, the PP was activated. Successful management was determined by the absence of perioperative complications within 6 months of implantation. We identified four cases, all receiving inflatable PPs, managed with temporary suprapubic cystostomy. These patients sustained urethral injuries during corporal dissection (one patient), corporal dilation (one patient), and penile straightening (two patients). All patients were managed safely and successfully. Primary urethral repair followed by temporary suprapubic cystostomy offers a surgical approach to complete PP implantation successfully in patients who sustain urethral injury complications, particularly for complex PP surgeries. Anele UA, Le BV, and Burnett AL. Suprapubic cystostomy for the management of urethral injuries during penile prosthesis implantation.

  12. MRI evaluation of post-mastectomy irradiated breast implants: prevalence and analysis of complications.

    Science.gov (United States)

    Rella, L; Telegrafo, M; Nardone, A; Milella, A; Stabile Ianora, A A; Lioce, M; Angelelli, G; Moschetta, M

    2015-09-01

    To evaluate the effect of post-mastectomy radiation therapy (RT) on breast implants as detected by magnetic resonance imaging (MRI) searching for short-term complications. One hundred and forty patients (total of 144 implants) were evaluated by MRI; 80 (group 1) had undergone RT, whereas the remaining 60 patients (group 2) underwent mastectomy with implant reconstruction without RT. Two radiologists evaluated MRI images searching for implant rupture signs, sub-capsular seromas, capsular contracture, soft-tissue oedema, peri-implant fluid collections. Implant ruptures were classified as severe complications; seromas and capsular contractures as moderate complications; oedema and fluid collections as mild complications. The prevalence of MRI findings in the two groups was calculated and compared by unpaired t-test. Cohen's kappa statistics was used to assess interobserver agreement. Sixty-nine out of 144 (48%) implants presented pathological findings at MRI with complication rates of 47.5 and 48.4 for groups 1 and 2, respectively. Two (5%) severe complications, 10 (26%) moderate complications, and 26 (69%) mild complications occurred in group 1 and surgical treatment was performed in 10 cases. Two (6%) severe complications, seven (23%) moderate complications, and 22 (71%) mild complications occurred in group 2 and surgical treatment was performed in eight cases. No significant difference between the two groups was found (p>0.1). Almost perfect agreement between the two radiologists was found for MRI image detection (k=0.86). RT does not seem to cause a significant effect on breast implants in terms of complication rate in patients undergoing implant-based breast reconstruction. One-stage immediate implant-based breast reconstruction performed at the same time as mastectomy could be proposed. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. Surgical implications of perimodiolar cochlear implant electrode design: avoiding intracochlear damage and scala vestibuli insertion.

    Science.gov (United States)

    Briggs, R J; Tykocinski, M; Saunders, E; Hellier, W; Dahm, M; Pyman, B; Clark, G M

    2001-09-01

    To review the mechanisms and nature of intracochlear damage associated with cochlear implant electrode array insertion, in particular, the various perimodiolar electrode designs. Make recommendations regarding surgical techniques for the Nucleus Contour electrode to ensure correct position and minimal insertion trauma. The potential advantages of increased modiolar proximity of intracochlear multichannel electrode arrays are a reduction in stimulation thresholds, an increase in dynamic range and more localized neural excitation. This may improve speech perception and reduce power consumption. These advantages may be negated if increased intracochlear damage results from the method used to position the electrodes close to the modiolus. A review of the University of Melbourne Department of Otolaryngology experience with temporal bone safety studies using the Nucleus standard straight electrode array and a variety of perimodiolar electrode array designs; comparison with temporal bone insertion studies from other centres and postmortem histopathology studies reported in the literature. Review of our initial clinical experience using the Nucleus Contour electrode array. The nature of intracochlear damage resulting from electrode insertion trauma ranges from minor, localized, spiral ligament tear to diffuse organ of Corti disruption and osseous spiral lamina fracture. The type of damage depends on the mechanical characteristics of the electrode array, the stiffness, curvature and size of the electrode in relation to the scala, and the surgical technique. The narrow, flexible, straight arrays are the least traumatic. Pre-curved or stiffer arrays are associated with an incidence of basilar membrane perforation. The cochleostomy must be correctly sited in relation to the round window to ensure scala tympani insertion. A cochleostomy anterior to the round window rather than inferior may lead to scala media or scala vestibuli insertion. Proximity of electrodes to the modiolus

  14. Influence of cochlear implantation on peripheral vestibular receptor function.

    Science.gov (United States)

    Krause, Eike; Louza, Julia P R; Wechtenbruch, Juliane; Gürkov, Robert

    2010-06-01

    The objectives of this study were 1) to assess the influence of a cochlear implantation on peripheral vestibular receptor function in the inner ear in the implant and in the nonimplant side, and 2) to analyze a possible correlation with resulting vertigo symptoms. Prospective clinical study. Cochlear implant center at tertiary referral hospital. A total of 32 patients, aged 15 to 83 years, undergoing cochlear implantation were assessed pre- and postoperatively for caloric horizontal semicircular canal response and vestibular-evoked myogenic potentials of the sacculus, and postoperatively for subjective vertigo symptoms. Patients with vertigo were compared with patients without symptoms with regard to the findings of the vestibular function tests. Cochlear implantation represents a significant risk factor for horizontal semicircular canal impairment (P 0.05). Cochlear implantation is a relevant risk factor for damage of peripheral vestibular receptor function. Therefore, preservation not only of residual hearing function but also of vestibular function should be aimed for, by using minimally invasive surgical techniques. Copyright 2010 American Academy of Otolaryngology-Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  15. Staged Hard and Soft Tissue Reconstruction Followed by Implant Supported Restoration in the Aesthetic Zone: A Case Report.

    Science.gov (United States)

    Parthasarathy, Harinath; Ramachandran, Lakshmi; Tadepalli, Anupama; Ponnaiyan, Deepa

    2017-04-01

    Alveolar ridge deficiency is a common clinical consequence following tooth loss due to chronic periodontitis complicating ideal implant placement. Advanced hard and soft tissue augmentation procedures have been developed in the recent past with predictable clinical outcomes. A male patient presented with a Grade III mobile upper right central incisor associated with advanced bone loss and soft tissue deficit. Following extraction of tooth #11, socket augmentation was done using an autogenous cortico-cancellous block graft and subsequent soft tissue augmentation was done with palatal connective tissue graft. At the end of six months, a tapered self tapping implant fixture was placed with adequate primary stability and after eight weeks, second stage implant surgery was done with the Misch technique in order to recreate papillae and the implant was prosthetically restored. The alveolar ridge was adequately recontoured following the staged surgical protocol. The implant was well integrated at the end of 15 months. Execution of sequential surgical procedures in a highly deficient edentulous site made it possible to achieve of optimal pink and white aesthetics with stable implant supported fixed prosthesis.

  16. A trabecular metal implant 4 months after placement: clinical-histologic case report.

    Science.gov (United States)

    Spinato, Sergio; Zaffe, Davide; Felice, Pietro; Checchi, Luigi; Wang, Hom-Lay

    2014-02-01

    The aim of this case report was to histologically evaluate the behavior of a trabecular metal (TM) implant composed of titanium and spatial 3-dimensional tantalum (Ta) trabeculae. This study is the first human histologic case report of this implant. A TM implant was placed in a 54-year-old woman exhibiting moderate chronic periodontitis. After periodontal treatment, the implant was inserted under favorable clinical conditions. Patient was not seen for 4 months because of unrelated breast reduction surgery. At the surgical reopening, periimplant inflammation affecting the coronal third of the implant was observed 4 months after implant placement. With patient's consent, the implant was removed for histologic analysis. Histology highlighted a greater amount of bone in close contact with Ta trabeculae than titanium surfaces. The finding of bone formation around the Ta trabeculae suggests that trabecular metal material promotes bone ingrowth for secondary implant stability. Additional evidence is needed to confirm this observation.

  17. Evolution of bone biomechanical properties at the micrometer scale around titanium implant as a function of healing time

    International Nuclear Information System (INIS)

    Vayron, Romain; Mathieu, Vincent; Haiat, Guillaume; Matsukawa, Mami; Tsubota, Ryo; Barthel, Etienne

    2014-01-01

    The characterization of the biomechanical properties of newly formed bone tissue around implants is important to understand the osseointegration process. The objective of this study is to investigate the evolution of elastic properties of newly formed bone tissue as a function of healing time. To do so, nanoindentation and micro-Brillouin scattering techniques are coupled following a multimodality approach using histological analysis. Coin-shaped implants were placed in vivo at a distance of 200 µm from the cortical bone surface, leading to an initially empty cavity. Two rabbits were sacrificed after 7 and 13 weeks of healing time. The histological analyses allow us to distinguish mature and newly formed bone tissue. The bone mechanical properties were measured in mature and newly formed bone tissue. Analysis of variance and Tukey–Kramer tests reveals a significant effect of healing time on the indentation modulus and ultrasonic velocities of bone tissue. The results show that bone mass density increases by 12.2% (2.2% respectively) between newly formed bone at 7 weeks (13 weeks respectively) and mature bone. The dependence of bone properties on healing time may be explained by the evolution of bone microstructure and mineralization. (paper)

  18. [A totally implantable venous access device. Implantation in general or local anaesthesia? A retrospective cost analysis].

    Science.gov (United States)

    Schuld, J; Richter, S; Moussavian, M R; Kollmar, O; Schilling, M K

    2009-08-01

    Implantation of venous access port systems can be performed in local or general anesthesia. In spite of the increasing rate of interventionally implanted systems, the surgical cut-down represents a safe alternative. Thus, the question arises whether--in context to the increasing health-economic pressure--open implantation in general anesthesia is still a feasible alternative to implantation in local anesthesia regarding OR efficiency and costs. In a retrospective analysis, 993 patients receiving a totally implantable venous access device between 2001 and 2007 were evaluated regarding OR utilization, turnover times, intraoperative data and costs. Implantations in local (LA) and general anesthesia (GA) were compared. GA was performed in 762 cases (76.6 %), LA was performed in 231 patients (23.3 %). Mean operation time was similar in both groups (LA 47.27 +/- 1.40 min vs. GA 45.41 +/- 0.75 min, p = 0.244). Patients receiving local anesthesia had a significantly shorter stay in the OR unit (LA 95.9 +/- 1.78 min vs. GA 105.92 +/- 0.92 min; p cut (LA 39.57 +/- 0.69 min vs. GA 50.46 +/- 0.52 min; p material costs were significantly lower in the LA group compared with the GA group (LA: 400.72 +/- 8.25 euro vs. GA: 482.86 +/- 6.23 euro; p systems in local anesthesia is superior in comparison to the implantation under general anesthesia regarding procedural times in the OR unit and costs. With the same operation duration, but less personnel and material expenditure, implantation in local anesthesia offers a potential economic advantage by permitting faster changing times. Implantation in GA only should be performed at a special request by the patient or in difficult venous conditions. Georg Thieme Verlag Stuttgart.New York.

  19. PIXE microbeam analysis of the metallic debris release around endosseous implants

    International Nuclear Information System (INIS)

    Buso, G.P.; Galassini, S.; Moschini, G.; Passi, P.; Zadro, A.; Uzunov, N.M.; Doyle, B.L.; Rossi, P.; Provencio, P.

    2005-01-01

    The mechanical friction that occurs during the surgical insertion of endosseous implants, both in dentistry and orthopaedics, may cause the detachment of metal debris which are dislodged into the peri-implant tissues and can lead to adverse clinical effects. This phenomenon more likely happens with coated or roughened implants that are the most widely employed. In the present study were studied dental implants screws made of commercially pure titanium and coated using titanium plasma-spray (TPS) technique. The implants were inserted in the tibia of rabbits, and removed 'en bloc' with the surrounding bone after one month. After proper processing and mounting on plastic holders, samples from bones were analysed by EDXRF setup at of National Laboratories of Legnaro, INFN, Italy, and consequently at 3 MeV proton microbeam setup at Sandia National Laboratories. Elemental maps were drawn, showing some occasional presence of metal particles in the peri-implant bone

  20. Improved procedure for implanting radiotransmitters in the coelomic cavity of snakes.

    Science.gov (United States)

    Bryant, G L; Eden, P; De Tores, P; Warren, K

    2010-11-01

    To investigate the expulsion of radiotransmitters in snakes and modify the surgical technique for coelomic implantation to prevent its occurrence. To enable monitoring of snakes for an ecological study, radiotransmitters were implanted in 23 south-west carpet pythons (Morelia spilota imbricata) using the standard surgical technique. In a further 23 pythons we used a refinement of the technique, which anchored the tracking device, using non-dissolvable sutures, to the snake's rib-cage. We also investigated the potential mechanisms for expelling the radiotransmitters in one snake that underwent an exploratory coeliotomy. Of the initial group of snakes, 12 (52%) expelled the radiotransmitter between 4 days and 3 years post implantation. In the later group, which underwent the refined technique of implantation, none of the radiotransmitters was expelled and no adverse responses were observed. An appropriately sized radiotransmitter anchored to the rib-cage of the snake will prevent expulsion of the device and appears to be well tolerated. Non-attachment of the tracking device enables it to migrate along the length of the body, particularly during feeding and reproduction. Caudal positioning of the transmitter's antenna provides a possible pathogenesis for expulsion into the cloaca. © 2010 The Authors. Australian Veterinary Journal © 2010 Australian Veterinary Association.

  1. [Multi-channel cochlear implants in patients with Mondini malformation].

    Science.gov (United States)

    Li, Yong-xin; Han, De-min; Zhao, Xiao-tian; Chen, Xue-qing; Kong, Ying; Zheng, Jun; Liu, Bo; Liu, Sha; Mo, Ling-yan; Zhang, Hua; Wang, Shuo

    2004-02-01

    To describe clinical experiences with multi-channel cochlear implantation in patients with Mondini malformation. Among 300 patients who received multi-channel cochlear implants from 1996 to 2002 in Beijing Tongren Hospital, 15 patients were diagnosed with Mondini malformation. A retrospective analysis was performed dealing with the surgical techniques, mapping and rehabilitations characteristics after surgery. 15 patients with normal cochlear structure are consider as control group. Gusher is found more common than the normal cochlear implantation, most of them are serious. The electrodes are inserted in the "cochleostomy" in full length of 13 Patients, 2 pairs of electrodes remains outside of "cochleostomy" in 2 patients. No serious complications occurred after implantation. All patients have auditory sensations. The impedance of the electrodes, the T level, C level and the hearing threshold are similar with the normal cochlear implantation group. The results have no significant difference in compare with normal cochlear group(P > 0.05). Multi-channel cochlear implantation could be performed safely in patients with Mondini malformation. The primary outcome for patients with Mondini malformation are similar to those with normal cochlear structure following the multi-channel cochlear implantation.

  2. Molteno3 Implantation as Primary Glaucoma Surgery

    Directory of Open Access Journals (Sweden)

    Juha O. Välimäki

    2014-01-01

    Full Text Available Purpose. To determine the outcome of Molteno3 implantation as primary glaucoma surgery and to analyze the factors influencing the surgical outcome. Methods. This is a retrospective clinical study of 106 consecutive eyes (97 patients with no previous glaucoma surgery. Surgical failure was defined as an IOP > 21 mmHg or less than a 20% reduction below baseline, or IOP ≤ 5 mmHg, on two consecutive visits after 3 months follow-up, or reoperation for glaucoma or loss of light perception. Results. At the end of the follow-up (mean, 35 months; range, 12–71 months, the mean postoperative IOP (14.2 ± 4.4 mmHg was statistically significantly lower than the preoperative IOP (35.2 ± 9.7 mmHg (P<0.001. Life-table success rates were 97%, 94%, and 91% after follow-up of 12, 24, and 36 months, respectively. Success rate for an IOP ≤ 18 mmHg was 77% at the last visit. Success was not influenced by previous cataract surgery, sex, age, laser trabeculoplasty (LTP, preoperative IOP, or number of antiglaucoma medications. Forty-seven eyes had 66 postoperative complications. Conclusions. The primary Molteno3 implant provided significant IOP lowering with minimal and manageable complications in uncontrolled glaucoma. Neither previous cataract surgery nor LTP had any detrimental effect on surgical success.

  3. Esthetics of Flapless Single-Tooth Implants in the Anterior Maxilla Using Guided Surgery: Association of Three-Dimensional Accuracy and Pink Esthetic Score.

    Science.gov (United States)

    Fürhauser, Rudolf; Mailath-Pokorny, Georg; Haas, Robert; Busenlechner, Dieter; Watzek, Georg; Pommer, Bernhard

    2015-10-01

    Flapless implant placement using surgical templates may guarantee predictable and esthetic results provided that preplanned implant positions are transfered precisely into surgical reality. The study aims to investigate the effect of three-dimensional accuracy in guided implant surgery on the esthetic outcome of single-tooth implants in the anterior maxilla. Single-tooth implants for delayed replacement of upper incisors were inserted in 27 patients using stereolithographic templates. Superimposition of postoperative cone beam computed tomography (CBCT) scans allowed assessment of positional inaccuracy at the implant shoulder and apex, as well as angular deviation. Objective evaluation of implant esthetics was performed after a mean follow-up of 2.3 years using the Pink Esthetic Score (PES). Mean deviation between planned and actual implant position was 0.84 mm at the implant shoulder and significantly correlated to average PES of 12 (p = .031). Inaccuracy toward the buccal side was most frequent (70%). Deviations  ≥  0.8  mm resulted in significantly worse implant esthetics (median PES: 9.5, interquartile range [IQR]: 8-11) compared with more accurate implant positions (median PES: 13, IQR: 12-13, p = .039). Positional inaccuracy is low in guided implant surgery, but may however significantly compromise implant esthetics in the anterior maxilla. © 2014 Wiley Periodicals, Inc.

  4. Cephalomedullary fixation for femoral neck/intertrochanteric and ipsilateral shaft fractures: surgical tips and pitfalls

    Directory of Open Access Journals (Sweden)

    Bali Kamal

    2013-02-01

    Full Text Available 【Abstract】Objective: Surgical management op-tions for femoral shaft fracture and ipsilateral proximal fe-mur fracture vary from single-implant to double-implant fixation. Cephalomedullary fixation in such fractures has rela-tive advantages over other techniques especially because of less soft tissue dissection and immediate postoperative weight bearing with accelerated rehabilitation. However, the surgery is technically demanding and there is a paucity of literature describing the surgical techniques for this fixation. The aim of the study was to describe the surgical technique of cephalomedullary fixation for femoral shaft fracture and ipsilateral proximal femur fracture. Methods: Sixteen cases (10 males and 6 females with a mean age of 41.8 years of ipsilateral proximal femur and shaft fractures were treated by single-stage cephalomedullary fixa-tion at tertiary level trauma center in northern India. The fractures were classified according to AO classification. An intraoperative record of duration of surgery as well as tech-nical challenges unique to each fracture pattern was kept for all the patients. Results: The most common proximal femoral pattern was AO B2.1 observed in 9 of our patients. The AO B2.3 fractures were seen in 4 patients while the AO A1.2 fractures in 3 patients. Four of the AO B2.1 and 2 of the AO B2.3 frac-tures required open reduction with Watson-Jones approach. The mean operative time was around 78 minutes, which tended to decrease as the surgical experience increased. There was only one case of malreduction, which required revision surgery. Conclusion: Combination of ipsilateral femoral shaft fracture and neck/intertrochanteric fracture is a difficult frac-ture pattern for trauma surgeons. Cephalomedullary nail is an excellent implant for such fractures but it requires careful insertion to avoid complications. Surgery is technically de-manding with a definite learning curve. Nevertheless, a ma-jority of these

  5. MRI evaluation of post-mastectomy irradiated breast implants: prevalence and analysis of complications

    International Nuclear Information System (INIS)

    Rella, L.; Telegrafo, M.; Nardone, A.; Milella, A.; Ianora, A.A. Stabile; Lioce, M.; Angelelli, G.; Moschetta, M.

    2015-01-01

    Aim: To evaluate the effect of post-mastectomy radiation therapy (RT) on breast implants as detected by magnetic resonance imaging (MRI) searching for short-term complications. Materials and methods: One hundred and forty patients (total of 144 implants) were evaluated by MRI; 80 (group 1) had undergone RT, whereas the remaining 60 patients (group 2) underwent mastectomy with implant reconstruction without RT. Two radiologists evaluated MRI images searching for implant rupture signs, sub-capsular seromas, capsular contracture, soft-tissue oedema, peri-implant fluid collections. Implant ruptures were classified as severe complications; seromas and capsular contractures as moderate complications; oedema and fluid collections as mild complications. The prevalence of MRI findings in the two groups was calculated and compared by unpaired t-test. Cohen's kappa statistics was used to assess interobserver agreement. Results: Sixty-nine out of 144 (48%) implants presented pathological findings at MRI with complication rates of 47.5 and 48.4 for groups 1 and 2, respectively. Two (5%) severe complications, 10 (26%) moderate complications, and 26 (69%) mild complications occurred in group 1 and surgical treatment was performed in 10 cases. Two (6%) severe complications, seven (23%) moderate complications, and 22 (71%) mild complications occurred in group 2 and surgical treatment was performed in eight cases. No significant difference between the two groups was found (p>0.1). Almost perfect agreement between the two radiologists was found for MRI image detection (k=0.86). Conclusion: RT does not seem to cause a significant effect on breast implants in terms of complication rate in patients undergoing implant-based breast reconstruction. One-stage immediate implant-based breast reconstruction performed at the same time as mastectomy could be proposed. -- Highlights: •RT could increase complication rates of implant-based breast reconstruction (IBR). •No general consensus

  6. Post-operative orbital imaging: a focus on implants and prosthetic devices

    International Nuclear Information System (INIS)

    Adams, Ashok; Mankad, Kshitij; Poitelea, Cornelia; Verity, David H.; Davagnanam, Indran

    2014-01-01

    Accurate interpretation of orbital imaging in the presence of either orbital implants requires a sound knowledge of both the surgical approach used and the imaging characteristics of the implanted devices themselves. In this article, the radiological appearance of the various devices used in ophthalmology, and their relationship to other orbital structures, is reviewed. In addition, the intended anatomical location, function of these devices, and clinical indications for their use are provided. (orig.)

  7. Novel surgical procedures in glaucoma: advances in penetrating glaucoma surgery.

    Science.gov (United States)

    Filippopoulos, Theodoros; Rhee, Douglas J

    2008-03-01

    Despite late modifications and enhancements, traditional penetrating glaucoma surgery is not without complications and is reserved for patients in whom pharmacologic treatment and/or laser trabeculoplasty do not suffice to control the intraocular pressure. This article critically reviews recent advances in penetrating glaucoma surgery with particular attention paid to two novel surgical approaches: ab interno trabeculectomy with the Trabectome and implantation of the Ex-PRESS shunt. Ab interno trabeculectomy (Trabectome) achieves a sustained 30% reduction in intraocular pressure by focally ablating and cauterizing the trabecular meshwork/inner wall of Schlemm's canal. It has a remarkable safety profile with respect to early hypotonous or infectious complications as it does not generate a bleb, but it can be associated with early postoperative intraocular pressure spikes that may necessitate additional glaucoma surgery. The Ex-PRESS shunt is more commonly implanted under a partial thickness scleral flap, and appears to have similar efficacy to standard trabeculectomy offering some advantages with respect to the rate of early complications related to hypotony. Penetrating glaucoma surgery will continue to evolve. As prospective randomized clinical trials become available, we will determine the exact role of these surgical techniques in the glaucoma surgical armamentarium.

  8. Soft tissue grafting to improve implant esthetics

    Directory of Open Access Journals (Sweden)

    Moawia M Kassab

    2010-09-01

    Full Text Available Moawia M KassabDivision of Periodontics, Marquette University, School of Dentistry, Milwaukee, WI, USAAbstract: Dental implants are becoming the treatment of choice to replace missing teeth, especially if the adjacent teeth are free of restorations. When minimal bone width is present, implant placement becomes a challenge and often resulting in recession and dehiscence around the implant that leads to subsequent gingival recession. To correct such defect, the author turned to soft tissue autografting and allografting to correct a buccal dehiscence around tooth #24 after a malpositioned implant placed by a different surgeon. A 25-year-old woman presented with the chief complaint of gingival recession and exposure of implant threads around tooth #24. The patient received three soft tissue grafting procedures to augment the gingival tissue. The first surgery included a connective tissue graft to increase the width of the keratinized gingival tissue. The second surgery included the use of autografting (connective tissue graft to coronally position the soft tissue and achieve implant coverage. The third and final surgery included the use of allografting material Alloderm to increase and mask the implant from showing through the gingiva. Healing period was uneventful for the patient. After three surgical procedures, it appears that soft tissue grafting has increased the width and height of the gingiva surrounding the implant. The accomplished thickness of gingival tissue appeared to mask the showing of implant threads through the gingival tissue and allowed for achieving the desired esthetic that the patient desired. The aim of the study is to present a clinical case with soft tissue grafting procedures.Keywords: case report, connective tissue, dental implants, allograft, coronally positioned flap

  9. Integration of implant planning workflows into the PACS infrastructure

    Science.gov (United States)

    Gessat, Michael; Strauß, Gero; Burgert, Oliver

    2008-03-01

    The integration of imaging devices, diagnostic workstations, and image servers into Picture Archiving and Communication Systems (PACS) has had an enormous effect on the efficiency of radiology workflows. The standardization of the information exchange between the devices with the DICOM standard has been an essential precondition for that development. For surgical procedures, no such infrastructure exists. With the increasingly important role computerized planning and assistance systems play in the surgical domain, an infrastructure that unifies the communication between devices becomes necessary. In recent publications, the need for a modularized system design has been established. A reference architecture for a Therapy Imaging and Model Management System (TIMMS) has been proposed. It was accepted by the DICOM Working Group 6 as the reference architecture for DICOM developments for surgery. In this paper we propose the inclusion of implant planning systems into the PACS infrastructure. We propose a generic information model for the patient specific selection and positioning of implants from a repository according to patient image data. The information models are based on clinical workflows from ENT, cardiac, and orthopedic surgery as well as technical requirements derived from different use cases and systems. We show an exemplary implementation of the model for application in ENT surgery: the selection and positioning of an ossicular implant in the middle ear. An implant repository is stored in the PACS. It makes use of an experimental implementation of the Surface Mesh Module that is currently being developed as extension to the DICOM standard.

  10. Influence of implant properties and local delivery systems on the outcome in operative fracture care.

    Science.gov (United States)

    Metsemakers, W-J; Moriarty, T F; Nijs, S; Pape, H C; Richards, R G

    2016-03-01

    Fracture fixation devices are implanted into a growing number of patients each year. This may be attributed to an increase in the popularity of operative fracture care and the development of ever more sophisticated implants, which may be used in even the most difficult clinical cases. Furthermore, as the general population ages, fragility fractures become more frequent. With the increase in number of surgical interventions, the absolute number of complications of these surgical treatments will inevitably rise. Implant-related infection and compromised fracture healing remain the most challenging and prevalent complications in operative fracture care. Any strategy that can help to reduce these complications will not only lead to a faster and more complete resumption of activities, but will also help to reduce the socio-economic impact. In this review we describe the influence of implant design and material choice on complication rates in trauma patients. Furthermore, we discuss the importance of local delivery systems, such as implant coatings and bone cement, and how these systems may have an impact on the prevalence, prevention and treatment outcome of these complications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Sequential transcatheter aortic valve implantation due to valve dislodgement

    DEFF Research Database (Denmark)

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected...

  12. Straightforward Case of Dental Implant in General Dentistry

    Directory of Open Access Journals (Sweden)

    Aji P. Tjikman

    2013-07-01

    Full Text Available Dental implant has become a fast developing and dynamic field in dental practice. It is acknowledged as a predictable treatment modality with high clinical success rates. Conventional fixed prostheses are no longer considered to be the first choice of treatment for replacing a missing tooth. Despite the increasing number of patients requesting dental implant treatments, there are only some clinicians who are offering implant therapy in their daily practice. The International team for Implantology described a straightforward case as a simple case such as implant placements in adquate soft and hard tissue conditions and single-tooth restorations in a non-aesthetic zone. A review of the current literature discussed the implementation of implant dentistry in universities worldwide into their curriculum for both undergraduate and postgraduate programs in general dentistry. The European consensus in implant dentistry education concluded that it is desirable to include the surgical technique for implant placement for straightforward cases into the dental curriculum. The levels and limitations to which the various aspects of implant dentistry and related skills are taught to be determined by the academic community. This review aimed at promoting awareness amongst dental practitioners and institutions in Indonesia of the shifting treatment paradigm in the maangement of a missing tooth. Hence clinicians will be able to include implant dentistry in the treatment planning of their patients and also undertake a significant part in the execution of such treatments.

  13. Surgeons' Perspectives on Premium Implants in Total Joint Arthroplasty.

    Science.gov (United States)

    Wasterlain, Amy S; Bello, Ricardo J; Vigdorchik, Jonathan; Schwarzkopf, Ran; Long, William J

    2017-09-01

    Declining total joint arthroplasty reimbursement and rising implant prices have led many hospitals to restrict access to newer, more expensive total joint arthroplasty implants. The authors sought to understand arthroplasty surgeons' perspectives on implants regarding innovation, product launch, costs, and cost-containment strategies including surgeon gain-sharing and patient cost-sharing. Members of the International Congress for Joint Reconstruction were surveyed regarding attitudes about implant technology and costs. Descriptive and univariate analyses were performed. A total of 126 surgeons responded from all 5 regions of the United States. Although 76.9% believed new products advance technology in orthopedics, most (66.7%) supported informing patients that new implants lack long-term clinical data and restricting new implants to a small number of investigators prior to widespread market launch. The survey revealed that 66.7% would forgo gain-sharing incentives in exchange for more freedom to choose implants. Further, 76.9% believed that patients should be allowed to pay incremental costs for "premium" implants. Surgeons who believed that premium products advance orthopedic technology were more willing to forgo gain-sharing (P=.040). Surgeons with higher surgical volume (P=.007), those who believed implant companies should be allowed to charge more for new technology (Pnew implants with patients. Many surgeons support alternative payment models permitting surgeons and patients to retain implant selection autonomy. Most respondents prioritized patient beneficence and surgeon autonomy above personal financial gain. [Orthopedics. 2017; 40(5):e825-e830.]. Copyright 2017, SLACK Incorporated.

  14. CAD/CAM technologies in the surgical and prosthetic treatment of the edentulous patient with biomymetic individualized approach.

    Science.gov (United States)

    Pozzi, A; Gargari, M; Barlattani, A

    2008-04-01

    The advent of modern endosseous implant design and improved surface technology has allowed the development of new restorative techniques that decrease patient's total treatment time. Utilizing the latest scanning, CAD/CAM and manufacturing technolgies we are able to manufacture individualized dental restoration with high accuracy and a perfect precision of fit. This report describes the rehabilitation of a completely edentulous patient utilizing a CT-based implant planning with computer-assisted surgical design, simultaneous CAD/CAM fabrication of a surgical template, a flapless surgical placement of the implants, and a prefabricated fixed complete denture for an immediately loaded restoration according to Nobel Biocare's Teeth-in-an-Hour™ (Nobel Biocare Goteborg, Sweden) protocol. This systematic approach to full mouth rehabilitation reduces the time necessary for an edentulous patient to go from severely atrophic alveolar support to implant retained prosthetic restoration. These aspects of minimally invasive and simplified surgery, along with reducing the treatment time and postsurgical discomfort, are beneficial to the patient, and allowing for rehabilitation with the same level of success as in flap surgery. The Teeth-in-an-Hour protocol is a unique solution made possible by the Procera System. With the aid of the CT scans and a virtual planning software, a custom fabricated precision drill guide and a pre-manufactured prosthesis can be made before surgery. The execution of implant placement is performed with a flapless procedure that results in minimal surgical intervention. This results in a short and non-traumatic surgery with a minimum of postoperative complications, allowing the patient to leave the chair with a fixed prosthesis. Utilizing the latest scanning, CAD/CAM and manufacturing technologies the dental team is able to develop individualized zirconia full arch framework with high accuracy and precision of fit.

  15. is there an increased risk of post-operative surgical site infection

    African Journals Online (AJOL)

    2012-09-06

    Sep 6, 2012 ... requiring implant orthopaedic surgery are at an increased risk for post-operative surgical ... further studies should determine the effect of reduced CD4 counts, viral load .... Language not Enlish, French, Ducth or German (n=2).

  16. Prognostic trend in advanced implant surgery.

    Science.gov (United States)

    Demitri, V; Polini, F; Robiony, M; Politi, M

    2002-03-01

    Implant surgery in association with bone grafting is generally considered less predictive than primary implant surgery. Many reports have been published about implant rehabilitation with bone grafts in atrophic patients. Most of these papers showed a lower implant success rate than primary implantology. The aim of this study is to verify if it's possible to warrant similar results between the two types of implantology, if such procedures are performed following effective protocols and criteria. From 1995 to 1999, 43 severely atrophic edentulous patients were treated in our Clinic with 63 autologous bone grafts and delayed implantology; 45 patients were treated with traditional implantology. 284 fixtures were positioned. The success rate in grafted implantology versus traditional implantology was compared for every maxillary and mandibular region. Furthermore, success rate in implantology of the anterior maxilla versus the poster maxilla in grafted patients was compared. The statistical considerations were performed with c2 test (p<0.05). The statistical analysis evidenced not significative difference in the implant success rate between grafted and not grafted patients in the anterior (p=0.23) and in the posterior maxilla (p=0.35). There was not significative difference in the implant success rate between grafted and not grafted patients in the anterior mandible (p=0.54) and in the posterior mandible (p=0.54). There was not significative difference in the implant success rate between the anterior and posterior grafted maxilla (p=0.21). The results obtained show that if close surgical protocol is performed it is possible to obtain no prognostic difference between the two METHODS.

  17. [Correction of congenital malformations by custom-made silicone implants: Contribution of computer-aided design. Experience of 611 cases].

    Science.gov (United States)

    Chavoin, J P; Chaput, B; Garrido, I; Moreno, B; Dahan, M; Grolleau, J L

    2016-10-01

    Modern techniques of computer-aided design and tridimensional prototyping for manufacturing silicone elastomer custom implants are growing. They have widely modified the surgical indications in our unit. By presenting their experience of 611 cases managed between 1993 and 2016, the authors describe the method of conception from CT-scans, the virtual image of the body and the manufacture of the custom-made implant perfectly adapted to the anatomy of each one. The operative techniques are described for the three main indications: the funnel chest or pectus excavatum (474 cases) according to a modified CHIN classification is corrected simply and very satisfactorily. This approach may render thoracic surgery techniques obsolete. Indeed, these operations remain risky and of doubtful functional utility; Poland syndrome (116 cases), where the use of a custom-made implant for compensation of muscle volume is frequently used, but can be improved by a transfer of adipose tissue or a classic breast implant; the leg atrophies (21 cases) receive custom elastomer implants introduced in a sub-fascial plane. The results are excellent for pectus excavatum but more difficult to optimize for the other two indications, requiring sometimes complementary techniques. Complications are rare and often benign, implants endure for life. Quality of life, psychological comfort and self-esteem have been improved with low morbidity and without having undergone a painful surgical experience. Reconstructive procedures of congenital malformations by custom-made silicone implants open a new field of activity for our surgical specialty with vast opportunities. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  18. Cochlear Implant

    Directory of Open Access Journals (Sweden)

    Mehrnaz Karimi

    1992-04-01

    Full Text Available People with profound hearing loss are not able to use some kinds of conventional amplifiers due to the nature of their loss . In these people, hearing sense is stimulated only when the auditory nerve is activated via electrical stimulation. This stimulation is possible through cochlear implant. In fact, for the deaf people who have good mental health and can not use surgical and medical treatment and also can not benefit from air and bone conduction hearing aids, this device is used if they have normal central auditory system. The basic parts of the device included: Microphone, speech processor, transmitter, stimulator and receiver, and electrode array.

  19. Perforated schneiderian membrane repair during sinus augmentation in conjunction with immediate implant placement

    Directory of Open Access Journals (Sweden)

    K Hameed Fathima

    2014-01-01

    Full Text Available Dental implant associated rehabilitation of the posterior maxilla poses unique challenge owing to the presence of pneumatized sinuses and atrophied alveolar bone. Sinus augmentation procedure to manage expanded sinuses frequently results in membrane tear resulting in unfavorable stabilization of the graft and associated bone regeneration. Simultaneous implant placement during sinus augmentation procedures frequently requires a minimal alveolar bone height, which when not present forces clinician to defer implant placement resulting in extended treatment duration and multiple surgical appointments. The present case report is about a piezosurgery assisted lateral wall osteotomy approach for sinus augmentation associated with membrane repair with simultaneous implant placement in the posterior maxilla.

  20. Treatment planning for permanent and temporary percutaneous implants with custom made templates

    International Nuclear Information System (INIS)

    Osian, A.D.; Anderson, L.L.; Linares, L.A.; Nori, D.; Hilaris, B.S.

    1989-01-01

    Nine patients who were presented at MSKCC with primary or recurrent pelvic or head and neck tumors and for whom surgery or further external radiation were excluded, were treated with percutaneous permanent or temporary implants, with individual pre-treatment planning and custom made templates. The tumor dose distributions achieved were as good as for implants performed at the time of surgical exploration. No serious complications have been encountered

  1. Rehabilitation of deaf persons with cochlear implants

    International Nuclear Information System (INIS)

    Gstoettner, W.; Hamzavi, J.; Czerny, C.

    1997-01-01

    In the last decade, the rehabilitation of postlingually deaf adults and prelingually deaf children with cochlear implants has been established as a treatment of deafness. The technological development of the implant devices and improvement of the surgical technique have led to a considerable increase of hearing performance during the last years. The postlingually deaf adults are able to use the telephone and may be integrated in their original job. Prelingually deaf children can even visit normal schools after cochlear implantation and hearing rehabilitation training. In order to preoperatively establish the state of the cochlear, radiological diagnosis of the temporal bone is necessary. High resolution computerized tomography imaging of the temporal bone with coronar and axial 1 mm slices and MRI with thin slice technique (three dimensional, T2 weighted turbo-spinecho sequence with 0.7 mm slices) have proved to be valuable according to our experience. Furthermore a postoperative synoptical X-ray, in a modified Chausse III projection, offers good information about the position of the implant and insertion of the stimulating electrode into the cochlea. (orig.) [de

  2. Multi-scale modeling of photopolymerization for medical hydrogel-implant design

    Science.gov (United States)

    Schmocker, Andreas; Khoushabi, Azadeh; Farahi, Salma; Pioletti, Dominique; Bourban, Pierre-Etienne; Manson, Jan A.; Moser, Christophe

    2013-02-01

    We report on the modeling of a photopolymerizable hydrogel and its application as a replacement of the interior of the intervertebral disc (so called Nucleus Pulposus). The hydrogel is initially injected in its liquid form and then photopolymerized via a small catheter. Therefore, also the light necessary for the photopolymerization is constrained to a small light guide to keep the surgical procedure as minimally invasive as possible. Hence, the hydrogel is photopolymerized inside. For applications with restricted physical access and illumination time, such as an Nucleus Pulposus replacement, photopolymerization of volumes with a large volume/illumination-area ratio becomes highly challenging. During polymerization, the material's absorption and scattering coefficients change and directly influence local polymerization rates. By understanding and controlling such polymerization patterns, local material properties can be engineered (e.g. elastic modulus, swelling ratio), to match the set of mechanical requirements for the implant. Thus, it is essential to better understand and model photopolymerization reactions. Experiments were conducted by polymerizing a hydrogel in a column-like volume using an optical fiber for light delivery. Quantitative scattering and absorption values as well as monomer conversion rates of the hydrogel sample were validated using a newly established Monte Carlo model for photopolymerization. The results were used to study and predict 3D polymerization patterns for different illumination configurations. In particular, we show an example of a lumbar intervertebral disc replacement where the jelly core of the intervertebral disc (Nucleus Pulposus) is replaced by an in situ photopolymerized hydrogel. The results provide insights for the development of novel endoscopic light-scattering polymerization probes paving the way for a new generation of implantable hydrogels.

  3. Lens subluxation grading system: predictive value for ectopia lentis surgical outcomes

    Directory of Open Access Journals (Sweden)

    Mauro Waiswol

    2009-03-01

    Full Text Available Objective: To present a classification system to grade ectopia lentis and to assess its usefulness as a predictor for surgical outcomes. Methods: Fifty-one eyes of 28 patients with either simple (19 patients or Marfan syndrome-associated ectopia lentis (nine patients with variable degrees of subluxation were operated on. Lens subluxation intensity was graded according to the lens subluxation grading system (LSGS from grade 1 (lens on the whole pupillary area up to grade 4 (lens absent from the pupillary area. Thirty eyes underwent cataract extraction (“dry” aspiration with endocapsular ring and in-the-bag intraocular lens (IOL implantation. Twenty-one eyes underwent cataract extraction (“dry” aspiration with scleral fixation of the IOL. The predictive value of the LSGS was assessed by analyzing the post-operative outcomes, including visual acuity (VA, endothelial cell loss, and complications for each grade on the grading system. Rresults: Patients were classified into grade 1 (19.6%, grade 2 (51% and grade 3 (29.4%. Post-operative VA was lower for eyes with larger degrees of subluxation. The higher the subluxation grade, the higher the endothelial cell loss, as well as, the frequency of vitreous loss and surgical time. Higher subluxation grades prevented optimal surgical outcomes with endocapsular ring and in-the-bag IOL implantation. Cconclusions: The LSGS provides an estimate of the surgical success of ectopia lentis. Adequate standardization of lens subluxation is crucial for understanding studies dealing with the surgical correction of this disorder.

  4. Surgical Management of Iatrogenic Pigment Dispersion Glaucoma.

    Science.gov (United States)

    Mierlo, Camille Van; Pinto, Luis Abegão; Stalmans, Ingeborg

    2015-01-01

    Iatrogenic pigment dispersion syndrome generally originates from a repetitive, mechanical trauma to the pigmented posterior epithelium of the iris. This trauma can arise after intraocular surgery, most commonly due to an abnormal contact between the intraocular lens (IOL) and the iris. Whether surgical removal of this primary insult can lead to a successful intraocular pressure (IOP) control remains unclear. Case-series. Patients with IOP elevation and clinical signs of pigment dispersion were screened for a diagnosis of iatrogenic IOL-related pigment dispersion. Three patients in which the IOL or the IOL-bag complex caused a pigment dispersion through a repetitive iris chafing were selected. In two cases, replacement of a sulcus-based single-piece IOL (patient 1) or a sub-luxated in-the-bag IOL (patient 2) by an anterior-chamber (AC) iris-fixed IOL led to a sustained decrease in IOP. In the third case, extensive iris atrophy and poor anatomical AC parameters for IOL implantation precluded further surgical intervention. IOL-exchange appears to be a useful tool in the management of iatrogenic pigment dispersion glaucoma due to inappropriate IOL implantation. This cause-oriented approach seems to be effective in controlling IOP, but should be offered only if safety criteria are met. How to cite this article: Van Mierlo C, Abegao Pinto L, Stalmans I. Surgical Management of Iatrogenic Pigment Dispersion Glaucoma. J Curr Glaucoma Pract 2015;9(1):28-32.

  5. Computer-assisted intraoperative visualization of dental implants. Augmented reality in medicine

    International Nuclear Information System (INIS)

    Ploder, O.; Wagner, A.; Enislidis, G.; Ewers, R.

    1995-01-01

    In this paper, a recently developed computer-based dental implant positioning system with an image-to-tissue interface is presented. On a computer monitor or in a head-up display, planned implant positions and the implant drill are graphically superimposed on the patient's anatomy. Electromagnetic 3D sensors track all skull and jaw movements; their signal feedback to the workstation induces permanent real-time updating of the virtual graphics' position. An experimental study and a clinical case demonstrates the concept of the augmented reality environment - the physician can see the operating field and superimposed virtual structures, such as dental implants and surgical instruments, without loosing visual control of the operating field. Therefore, the operation system allows visualization of CT planned implantposition and the implementation of important anatomical structures. The presented method for the first time links preoperatively acquired radiologic data, planned implant location and intraoperative navigation assistance for orthotopic positioning of dental implants. (orig.) [de

  6. Magnetic Resonance Imaging of Surgical Implants Made from Weak Magnetic Materials

    Science.gov (United States)

    Gogola, D.; Krafčík, A.; Štrbák, O.; Frollo, I.

    2013-08-01

    Materials with high magnetic susceptibility cause local inhomogeneities in the main field of the magnetic resonance (MR) tomograph. These inhomogeneities lead to loss of phase coherence, and thus to a rapid loss of signal in the image. In our research we investigated inhomogeneous field of magnetic implants such as magnetic fibers, designed for inner suture during surgery. The magnetic field inhomogeneities were studied at low magnetic planar phantom, which was made from four thin strips of magnetic tape, arranged grid-wise. We optimized the properties of imaging sequences with the aim to find the best setup for magnetic fiber visualization. These fibers can be potentially exploited in surgery for internal stitches. Stitches can be visualized by the magnetic resonance imaging (MRI) method after surgery. This study shows that the imaging of magnetic implants is possible by using the low field MRI systems, without the use of complicated post processing techniques (e.g., IDEAL).

  7. Radio-frequency plasma nitriding and nitrogen plasma immersion ion implantation of Ti-6Al-4V alloy

    International Nuclear Information System (INIS)

    Wang, S.Y.; Chu, P.K.; Tang, B.Y.; Zeng, X.C.; Wang, X.F.; Chen, Y.B.

    1997-01-01

    Nitrogen ion implantation improves the wear resistance of Ti-6Al-4V alloys by forming a hard TiN superficial passivation layer. However, the thickness of the layer formed by traditional ion implantation is typically 100-200 nm and may not be adequate for many industrial applications. We propose to use radio-frequency (RF) plasma nitriding and nitrogen plasma immersion ion implantation (PIII) to increase the layer thickness. By using a newly designed inductively coupled RF plasma source and applying a series of negative high voltage pulses to the Ti-6Al-4V samples. RF plasma nitriding and nitrogen PIII can be achieved. Our process yields a substantially thicker modified layer exhibiting more superior wear resistance characteristics, as demonstrated by data from micro-hardness testing, pin-on-disc wear testing, scanning electron microscopy (SEM), as well as Auger electron spectroscopy (AES). The performance of our newly developed inductively coupled RF plasma source which is responsible for the success of the experiments is also described. (orig.)

  8. [Cochlear implant in children: rational, indications and cost/efficacy].

    Science.gov (United States)

    Martini, A; Bovo, R; Trevisi, P; Forli, F; Berrettini, S

    2013-06-01

    A cochlear implant (CI) is a partially implanted electronic device that can help to provide a sense of sound and support speech to severely to profoundly hearing impaired patients. It is constituted by an external portion, that usually sits behind the ear and an internal portion surgically placed under the skin. The external components include a microphone connected to a speech processor that selects and arranges sounds pucked up by the microphone. This is connected to a transmitter coil, worn on the side of the head, which transmits data to an internal receiver coil placed under the skin. The received data are delivered to an array of electrodes that are surgically implanted within the cochlea. The primary neural targets of the electrodes are the spiral ganglion cells which innervate fibers of the auditory nerve. When the electrodes are activated by the signal, they send a current along the auditory nerve and auditory pathways to the auditory cortex. Children and adults who are profoundly or severely hearing impaired can be fitted with cochlear implants. According to the Food and Drug Administration, approximately 188,000 people worldwide have received implants. In Italy it is extimated that there are about 6-7000 implanted patients, with an average of 700 CI surgeries per year. Cochlear implantation, followed by intensive postimplantation speech therapy, can help young children to acquire speech, language, and social skills. Early implantation provides exposure to sounds that can be helpful during the critical period when children learn speech and language skills. In 2000, the Food and Drug Administration lowered the age of eligibility to 12 months for one type of CI. With regard to the results after cochlear implantation in relation to early implantation, better linguistic results are reported in children implanted before 12 months of life, even if no sufficient data exist regarding the relation between this advantage and the duration of implant use and how long

  9. Short dental implants: A scoping review of the literature for patients with head and neck cancer.

    Science.gov (United States)

    Edher, Faraj; Nguyen, Caroline T

    2017-09-16

    Dental implants can be essential in the rehabilitation of various cancer defects, but their ideal placement can be complicated by the limited dimensions of the available host bone. Surgical interventions developed to increase the amount of bone are not all predictable or successful and can sometimes be contraindicated. Short dental implants have been suggested as an alternative option in sites where longer implants are not possible. Whether they provide a successful treatment option is unclear. The purpose of this study was to review the literature on short dental implants and assess whether they are a viable definitive treatment option for rehabilitating cancer patients with deficient bone. A scoping review of the literature was performed, including a search of established periodontal textbooks for articles on short dental implants combined with a search of PubMed, MEDLINE, EMBASE, Web of Science, and Cochrane Database of Systematic Reviews. A search for all literature published before June 2016 was based on the following keywords: ['dental implants' OR 'dental implantation, endosseous' OR 'dental prosthesis, implant supported'] AND [short]. The minimum acceptable implant length has been considered to be 6 mm. The survival rates of short implants varied between 74% and 96% at 5 years, depending on factors such as the quality of the patient's bone, primary stability of the implant, clinician's learning curve, and implant surface. Short implants can achieve results similar to those of longer implants in augmented bone and offer a treatment alternative that could reduce the need for invasive surgery and associated morbidity and be safer and more economical. Short dental implants (6 mm to 8 mm) can be used successfully to support single or multiple fixed reconstructions or overdentures in atrophic maxillae and mandibles. The use of short dental implants lessens the need for advanced and complicated surgical bone augmentation procedures, which reduces complications

  10. Multicenter surgical experience evaluation on the Mid-Scala electrode and insertion tools.

    Science.gov (United States)

    Gazibegovic, Dzemal; Bero, Eva M

    2017-02-01

    The HiFocus Mid-Scala electrode is intended to improve hearing for individuals with severe-to-profound hearing loss by providing extended electrical coverage of the cochlea while minimizing trauma related to insertion. The electrode is appropriate for use with a wide range of surgical techniques, including either a cochleostomy or round window insertion, and the use of either a free-hand or tool-assisted approach. The objective of this survey was to evaluate how the HiFocus Mid-Scala electrode and insertion tools was used across a population of cochlear implant recipients of differing ages, audiologic profiles, and anatomical characteristics. The intent was to understand the type and frequency of surgical techniques applicable with the electrode, and to provide guidelines for clinical practice. Two questionnaires were completed by surgeons at implant centres located in the United States, Europe, and Asia. Before any surgeries were conducted, surgeons completed a questionnaire that assessed their overall cochlear implant surgical practice and preferences. Following each HiFocus Mid-Scala electrode insertion, surgeons completed a questionnaire that summarized their experience during that surgical procedure. Questionnaires were completed by 32 surgeons from 16 centres for a total of 143 surgeries (112 adults, 31 children). Most surgeons (62 %) preferred to insert the electrode via the round window or an extended round window compared with a cochleostomy (16 %), whereas the remaining 22 % indicated that they made an insertion choice based on presenting anatomy. Sixty-nine percent preferred a free-hand approach over using insertion tools. In 32 procedures, surgeons elected to deviate from an intended round window insertion to either an extended round window or cochleostomy approach.

  11. Moderate hypothermia technique for chronic implantation of a total artificial heart in calves.

    Science.gov (United States)

    Karimov, Jamshid H; Grady, Patrick; Sinkewich, Martin; Sunagawa, Gengo; Dessoffy, Raymond; Byram, Nicole; Moazami, Nader; Fukamachi, Kiyotaka

    2017-06-01

    The benefit of whole-body hypothermia in preventing ischemic injury during cardiac surgical operations is well documented. However, application of hypothermia during in vivo total artificial heart implantation has not become widespread because of limited understanding of the proper techniques and restrictions implied by constitutional and physiological characteristics specific to each animal model. Similarly, the literature on hypothermic set-up in total artificial heart implantation has also been limited. Herein we present our experience using hypothermia in bovine models implanted with the Cleveland Clinic continuous-flow total artificial heart.

  12. Piezosurgery in implant dentistry

    Science.gov (United States)

    Stübinger, Stefan; Stricker, Andres; Berg, Britt-Isabelle

    2015-01-01

    Piezosurgery, or the use of piezoelectric devices, is being applied increasingly in oral and maxillofacial surgery. The main advantages of this technique are precise and selective cuttings, the avoidance of thermal damage, and the preservation of soft-tissue structures. Through the application of piezoelectric surgery, implant-site preparation, bone grafting, sinus-floor elevation, edentulous ridge splitting or the lateralization of the inferior alveolar nerve are very technically feasible. This clinical overview gives a short summary of the current literature and outlines the advantages and disadvantages of piezoelectric bone surgery in implant dentistry. Overall, piezoelectric surgery is superior to other methods that utilize mechanical instruments. Handling of delicate or compromised hard- and soft-tissue conditions can be performed with less risk for the patient. With respect to current and future innovative surgical concepts, piezoelectric surgery offers a wide range of new possibilities to perform customized and minimally invasive osteotomies. PMID:26635486

  13. A PATIENT WITH EPIDERMAL CYST IN MANDIBULA, SIMULTANEOUSLY ENUCLEATION OF EPIDERMAL CYST AND IMPLANT PLACEMENT:

    OpenAIRE

    Terzi, Mithat; Karaaslan, Fatih; Çalık, Muhammed; Dilsiz, Alparslan; Altun, Eren

    2015-01-01

    Dermoid cysts are malformations that rarely seen in oral mucosa and can be defined as an epidermoid when lining presents only epithelium. Epidermoid and dermoid cysts are rarely seen in intraosseous and there was a few report about their presentation in the jaws. The development in implant surfaces and surgical techniques has led to changes in treatment protocol such as immediate implant placement. Immediate implant placement has some advantages such as, reduction in the time of treat- ment a...

  14. Osseointegration of loaded dental implant with KrF laser hydroxylapatite films on Ti6Al4V alloy by minipigs

    Science.gov (United States)

    Dostalova, Tatjana; Himmlova, Lucia; Jelinek, Miroslav; Grivas, Christos

    2001-04-01

    This study was performed with the objective of evaluating osseointegration of titanium alloy Ti6Al4V dental implants coated with hydroxylapatite (HA) deposited by a KrF laser. For this a KrF excimer laser and stainless-steel deposition chamber were used. The thickness of the HA films was approximately 1 micrometers . IN this investigation experimental animals minipigs were used; the implants were placed vertically into the lower jaw. After 14 weeks of unloaded osseointegration, metal-ceramic crowns were inserted and, at the same time, fluorescent solution was injected into the experimental animals. Six months after insertion of crowns the animals were sacrificed. The vertical position of the implants was checked by a radiograph. Microscopic sections were cut and ground, and the sections were examined under polarized and fluorescent light using a microscope with a charge coupled device camera. The six month long osseointegration in the lower jaw has confirmed the presence of newly formed bone around all the implants. In the experimental group, which had a laser-deposited coating, the layer of fibrous connective tissue was seen only randomly. In the control group (titanium implant without a cover) the fibrous connective tissue between the implant and the newly formed bone was observed more frequently, but this difference was not significant.

  15. Heat generated by dental implant drills during osteotomy-a review: heat generated by dental implant drills.

    Science.gov (United States)

    Mishra, Sunil Kumar; Chowdhary, Ramesh

    2014-06-01

    Osseointegration is the more stable situation and results in a high success rate of dental implants. Heat generation during rotary cutting is one of the important factors influencing the development of osseointegration. To assess the various factors related to implant drills responsible for heat generation during osteotomy. To identify suitable literature, an electronic search was performed using Medline and Pubmed database. Articles published in between 1960 to February 2013 were searched. The search is focused on heat generated by dental implant drills during osteotomy. Various factors related to implant drill such effect of number of blades; drill design, drill fatigue, drill speed and force applied during osteotomies which were responsible for heat generation were reviewed. Titles and abstracts were screened, and literature that fulfilled the inclusion criteria was selected for a full-text reading. The initial literature search resulted in 299 articles out of which only 70 articles fulfils the inclusion criteria and were included in this systematic review. Many factors related to implant drill responsible for heat generation were found. Successful preparation of an implant cavity with minimal damage to the surrounding bone depends on the avoidance of excessive temperature generation during surgical drilling. The relationship between heat generated and implant drilling osteotomy is multifactorial in nature and its complexity has not been fully studied. Lack of scientific knowledge regarding this issue still exists. Further studies should be conducted to determine the various factors which generate less heat while osteotomy such as ideal ratio of force and speed in vivo, exact time to replace a drill, ideal drill design, irrigation system, drill-bone contact area.

  16. Clinical and radiographic evaluation of early loaded narrow-diameter implants

    DEFF Research Database (Denmark)

    Maiorana, Carlo; King, Paul; Quaas, Sebastian

    2015-01-01

    OBJECTIVE: To evaluate the clinical reliability of narrow implants placed in a one-stage procedure and early loaded in the upper and lower incisor region. MATERIAL AND METHODS: This is a prospective, single-arm, multicenter study in which patients with missing natural dentition in upper lateral a...... be considered as a valid solution in the treatment of the localized narrow bony defects in the anterior area with reduced spaces between the natural teeth....... healing period. Clinical and radiographic checks were performed at implant placement, loading, and at the 6, 12, 24, and 36 months follow-up visits. RESULTS: A total of 69 subjects with 97 implants have been included in this study. From surgery to 36 months follow-up, 5.6% of the implants showed bone loss...... loss between loading and the 1-year follow-up visit (Galindo-Moreno et al. 2012). This finding, associated with a stable probing pocket depth and a stable crown-gingiva distance, using a one-stage surgical procedure helps to maintain the integrity of the peri-implant soft tissues. Narrow implants can...

  17. Aortic Root Enlargement or Sutureless Valve Implantation?

    Directory of Open Access Journals (Sweden)

    Nikolaos G. Baikoussis

    2016-11-01

    Full Text Available Aortic valve replacement (AVR in patients with a small aortic annulus is a challenging issue. The importance of prosthesis–patient mismatch (PPM post aortic valve replacement (AVR is controversial but has to be avoided. Many studies support the fact that PPM has a negative impact on short and long term survival. In order to avoid PPM, aortic root enlargement may be performed. Alternatively and keeping in mind that often some comorbidities are present in old patients with small aortic root, the Perceval S suturelles valve implantation could be a perfect solution. The Perceval sutureless bioprosthesis provides reasonable hemodynamic performance avoiding the PPM and providing the maximum of aortic orifice area. We would like to see in the near future the role of the aortic root enlargement techniques in the era of surgical implantation of the sutureless valve (SAVR and the transcatheter valve implantation (TAVI.

  18. Preoperative implant planning considering alveolar bone grafting needs and complication prediction using panoramic versus CBCT images

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero, Maria Eugenia; Jacobs, Reinhilde [OIC, OMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, University of Leuven, Leuven (Belgium); Noriega, Jorge [Master of Periodontology, Universidad San Martin de Porres, Lima (Peru)

    2014-09-15

    This study was performed to determine the efficacy of observers' prediction for the need of bone grafting and presence of perioperative complications on the basis of cone-beam computed tomography (CBCT) and panoramic radiographic (PAN) planning as compared to the surgical outcome. One hundred and eight partially edentulous patients with a need for implant rehabilitation were referred for preoperative imaging. Imaging consisted of PAN and CBCT images. Four observers carried out implant planning using PAN image datasets, and at least one month later, using CBCT image datasets. Based on their own planning, the observers assessed the need for bone graft augmentation as well as complication prediction. The implant length and diameter, the need for bone graft augmentation, and the occurrence of anatomical complications during planning and implant placement were statistically compared. In the 108 patients, 365 implants were installed. Receiver operating characteristic analyses of both PAN and CBCT preoperative planning showed that CBCT performed better than PAN-based planning with respect to the need for bone graft augmentation and perioperative complications. The sensitivity and the specificity of CBCT for implant complications were 96.5% and 90.5%, respectively, and for bone graft augmentation, they were 95.2% and 96.3%, respectively. Significant differences were found between PAN-based planning and the surgery of posterior implant lengths. Our findings indicated that CBCT-based preoperative implant planning enabled treatment planning with a higher degree of prediction and agreement as compared to the surgical standard. In PAN-based surgery, the prediction of implant length was poor.

  19. Recent advances in imaging technologies in implant dentistry

    Directory of Open Access Journals (Sweden)

    Sharad Sahai

    2015-01-01

    Full Text Available Dental implants have become a part of routine treatment plans in oral rehabilitation. Diagnostic imaging is critical to presurgical treatment planning and the success of implants. Various imaging modalities may aid the placing of implants in an appropriate location with relative ease and also obtain a predictable outcome. Cross-sectional imaging techniques such as computed tomography (CT and, more recently, cone beam-computed tomography (CBCT are invaluable during preoperative planning for endosseous dental implantation procedures. An understanding of geometric and software parameters, and image formatting options to maximize image display is necessary to optimize diagnostic yield while maintaining minimal patient radiation dose. Multiplanar CT or CBCT images contain far more detailed information of the maxillofacial region than do panoramic or other bidimensional (2D images and necessitate a thorough knowledge of the tridimensional (3D anatomy of the region and considerations of variability in the range of the anatomically normal. This article provides: (1 an overview of the fundamental principles of operation of maxillofacial CT and CBCT; (2 an understanding of image processing and display protocols specific to pre-implant bone assessment; (3 the basics of qualitative and quantitative bone evaluation; and (4 an introduction to image-guided implant surgery using custom or computer-generated surgical guides.

  20. Implantation of a new enteral stent in obstructive colorectal cancer using interventional radiology in patients over 70 years of age.

    Science.gov (United States)

    Miłek, Tomasz; Ciostek, Piotr

    2015-07-01

    Colorectal cancer is the second leading cause of death due to cancer in Poland. The traditional approach to treat patients included a surgical procedure. Irrespective of the surgical method being used, surgical treatment of malignant colorectal obstruction is associated with prolonged hospitalisation, and the postoperative mortality rate is approximately 5-11%. Due to these problems, more interest has been shown in less invasive methods. Prosthesis implantation is a leading endoscopic method used currently in palliative or preoperative treatment. To compare the results of implantation of traditional stents with the results of implantation of an own stent using minimally invasive methods. Left-sided colon obstruction due to cancer was an indication for transplantation. All patients were aged over 70 years and had serious concomitant diseases. The control group included 50 patients with colorectal cancer who received traditional stents in the period 2009-2011. Our stent covers only the internal length of a tumour. It is not equipped with anti-migration flares. To minimize the risk of migration it has a system of hooks that are responsible for permanent anchorage of the stent within the tumour mass. Implantation technical and clinical success defined as effective decompression of intestinal obstruction was 100% in both groups. There were 2 cases of stent migration in the control group. It is possible to achieve a secure surgical anastomosis after intestinal decompression. Stent implantation is fast and safe thanks to the positioning system that was used. The use of labelled hooks is a secure anti-migration solution.