  1. Consistent evaluation of an ultrasound-guided surgical navigation system by utilizing an active validation platform

    Science.gov (United States)

    Kim, Younsu; Kim, Sungmin; Boctor, Emad M.

    2017-03-01

    An ultrasound image-guided needle tracking systems have been widely used due to their cost-effectiveness and nonionizing radiation properties. Various surgical navigation systems have been developed by utilizing state-of-the-art sensor technologies. However, ultrasound transmission beam thickness causes unfair initial evaluation conditions due to inconsistent placement of the target with respect to the ultrasound probe. This inconsistency also brings high uncertainty and results in large standard deviations for each measurement when we compare accuracy with and without the guidance. To resolve this problem, we designed a complete evaluation platform by utilizing our mid-plane detection and time of flight measurement systems. The evaluating system uses a PZT element target and an ultrasound transmitting needle. In this paper, we evaluated an optical tracker-based surgical ultrasound-guided navigation system whereby the optical tracker tracks marker frames attached on the ultrasound probe and the needle. We performed ten needle trials of guidance experiment with a mid-plane adjustment algorithm and with a B-mode segmentation method. With the midplane adjustment, the result showed a mean error of 1.62+/-0.72mm. The mean error increased to 3.58+/-2.07mm without the mid-plane adjustment. Our evaluation system can reduce the effect of the beam-thickness problem, and measure ultrasound image-guided technologies consistently with a minimal standard deviation. Using our novel evaluation system, ultrasound image-guided technologies can be compared under equal initial conditions. Therefore, the error can be evaluated more accurately, and the system provides better analysis on the error sources such as ultrasound beam thickness.

  2. An ultrasound image-guided surgical workflow model

    Science.gov (United States)

    Guo, Bing; Lemke, Heinz; Liu, Brent; Huang, H. K.; Grant, Edward G.

    2006-03-01

    A 2003 report in the Journal of Annual Surgery predicted an increase in demand for surgical services to be as high as 14 to 47% in the workload of all surgical fields by 2020. Medical difficulties which are already now apparent in the surgical OR (Operation Room) will be amplified in the near future and it is necessary to address this problem and develop strategies to handle the workload. Workflow issues are central to the efficiency of the OR and in response to today's continuing workforce shortages and escalating costs. Among them include: Inefficient and redundant processes, System Inflexibility, Ergonomic deficiencies, Scattered Data, Lack of Guidelines, Standards, and Organization. The objective of this research is to validate the hypothesis that a workflow model does improve the efficiency and quality of surgical procedure. We chose to study the image-guided surgical workflow for US as a first proof of concept by minimizing the OR workflow issues. We developed, and implemented deformable workflow models using existing and projected future clinical environment data as well as a customized ICT system with seamless integration and real-time availability. An ultrasound (US) image-guided surgical workflow (IG SWF) for a specific surgical procedure, the US IG Liver Biopsy, was researched to find out the inefficient and redundant processes, scattered data in clinical systems, and improve the overall quality of surgical procedures to the patient.

  3. Elastography using multi-stream GPU: an application to online tracked ultrasound elastography, in-vivo and the da Vinci Surgical System.

    Directory of Open Access Journals (Sweden)

    Nishikant P Deshmukh

    Full Text Available A system for real-time ultrasound (US elastography will advance interventions for the diagnosis and treatment of cancer by advancing methods such as thermal monitoring of tissue ablation. A multi-stream graphics processing unit (GPU based accelerated normalized cross-correlation (NCC elastography, with a maximum frame rate of 78 frames per second, is presented in this paper. A study of NCC window size is undertaken to determine the effect on frame rate and the quality of output elastography images. This paper also presents a novel system for Online Tracked Ultrasound Elastography (O-TRuE, which extends prior work on an offline method. By tracking the US probe with an electromagnetic (EM tracker, the system selects in-plane radio frequency (RF data frames for generating high quality elastograms. A novel method for evaluating the quality of an elastography output stream is presented, suggesting that O-TRuE generates more stable elastograms than generated by untracked, free-hand palpation. Since EM tracking cannot be used in all systems, an integration of real-time elastography and the da Vinci Surgical System is presented and evaluated for elastography stream quality based on our metric. The da Vinci surgical robot is outfitted with a laparoscopic US probe, and palpation motions are autonomously generated by customized software. It is found that a stable output stream can be achieved, which is affected by both the frequency and amplitude of palpation. The GPU framework is validated using data from in-vivo pig liver ablation; the generated elastography images identify the ablated region, outlined more clearly than in the corresponding B-mode US images.

  4. Medical ultrasound systems.

    Science.gov (United States)

    Powers, Jeff; Kremkau, Frederick

    2011-08-06

    Medical ultrasound imaging has advanced dramatically since its introduction only a few decades ago. This paper provides a short historical background, and then briefly describes many of the system features and concepts required in a modern commercial ultrasound system. The topics addressed include array beam formation, steering and focusing; array and matrix transducers; echo image formation; tissue harmonic imaging; speckle reduction through frequency and spatial compounding, and image processing; tissue aberration; Doppler flow detection; and system architectures. It then describes some of the more practical aspects of ultrasound system design necessary to be taken into account for today's marketplace. It finally discusses the recent explosion of portable and handheld devices and their potential to expand the clinical footprint of ultrasound into regions of the world where medical care is practically non-existent. Throughout the article reference is made to ways in which ultrasound imaging has benefited from advances in the commercial electronics industry. It is meant to be an overview of the field as an introduction to other more detailed papers in this special issue.

  5. Ultrasound training in surgical residency: Is it feasible?

    Directory of Open Access Journals (Sweden)

    Srihari Sridhara

    2014-01-01

    Full Text Available Purpose: Ultrasound training for the surgical residents is not a common practice in India. This study was undertaken to prepare a working model for surgical trainees and assess its effectiveness by training a single surgical resident. Materials and Methods: This was a prospective study of 238 patients with pain abdomen. Training was given in abdominal ultrasound for a period of 2 months. Ultrasound scans were performed independently by a radiology resident and surgery resident. Inter-rater agreement between both residents was assessed using Kappa coefficient. Ultrasound results were compared with clinical diagnosis and final diagnosis. Results: The kappa agreement was 0.53, 0.56, 0.8 and 1 for urolithiasis, appendicitis, pancreatitis and urinary tract infection, respectively. Almost all cases of cholelithiasis were identified by the surgery resident. There was improvement of 21%, 31% and 100% in patients of urolithiasis, acute appendicitis and liver abscess, respectively, in the second 10 months of the study. Conclusions: Ultrasound scans can be performed by a surgery resident with similar results as that of a radiology resident. Training of the surgery resident is possible with satisfactory results.

  6. Ultrasound-guided surgical drainage of face and neck abscesses.

    Science.gov (United States)

    Yusa, H; Yoshida, H; Ueno, E; Onizawa, K; Yanagawa, T

    2002-06-01

    An ultrasound-guided surgical drainage technique in which grey-scale and colour Doppler ultrasonography were combined is described. The technique was performed for eight deep subcutaneous abscesses subsequent to odontogenic infection, and provided easy detection and accurate, reliable penetration of abscesses that were difficult to locate by physical examination. Colour Doppler ultrasonography is particularly useful for differentiating blood vessels from the static space of abscesses.

  7. Passive markers for tracking surgical instruments in real-time 3-D ultrasound imaging.

    Science.gov (United States)

    Stoll, Jeffrey; Ren, Hongliang; Dupont, Pierre E

    2012-03-01

    A family of passive echogenic markers is presented by which the position and orientation of a surgical instrument can be determined in a 3-D ultrasound volume, using simple image processing. Markers are attached near the distal end of the instrument so that they appear in the ultrasound volume along with the instrument tip. They are detected and measured within the ultrasound image, thus requiring no external tracking device. This approach facilitates imaging instruments and tissue simultaneously in ultrasound-guided interventions. Marker-based estimates of instrument pose can be used in augmented reality displays or for image-based servoing. Design principles for marker shapes are presented that ensure imaging system and measurement uniqueness constraints are met. An error analysis is included that can be used to guide marker design and which also establishes a lower bound on measurement uncertainty. Finally, examples of marker measurement and tracking algorithms are presented along with experimental validation of the concepts.

  8. Surgical vs ultrasound-guided drainage of deep neck space abscesses: a randomized controlled trial: surgical vs ultrasound drainage

    OpenAIRE

    2013-01-01

    Introduction Deep neck space abscesses (DNAs) are relatively common otolaryngology-head and neck surgery emergencies and can result in significant morbidity with potential mortality. Traditionally, surgical incision and drainage (I&D) with antibiotics has been the mainstay of treatment. Some reports have suggested that ultrasound-guided drainage (USD) is a less invasive and effective alternative in select cases. Objectives To compare I&D vs USD of well-defined DNAs, using a randomized control...

  9. Spacecraft surgical scrub system

    Science.gov (United States)

    Abbate, M.

    1980-01-01

    Ease of handling and control in zero gravity and minimizing the quantity of water required were prime considerations. The program tasks include the selection of biocidal agent from among the variety used for surgical scrub, formulation of a dispensing system, test, and delivery of flight dispensers. The choice of an iodophore was based on effectiveness on single applications, general familiarity among surgeons, and previous qualification for space use. The delivery system was a choice between the squeeze foamer system and impregnated polyurethane foam pads. The impregnated foam pad was recommended because it is a simpler system since the squeeze foamer requires some applicator to effectively clean the skin surfaces, whereas the form pad is the applicator and agent combined. Testing demonstrated that both systems are effective for use as surgical scrubs.

  10. Automatic localization of the da Vinci surgical instrument tips in 3-D transrectal ultrasound.

    Science.gov (United States)

    Mohareri, Omid; Ramezani, Mahdi; Adebar, Troy K; Abolmaesumi, Purang; Salcudean, Septimiu E

    2013-09-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) using the da Vinci surgical system is the current state-of-the-art treatment option for clinically confined prostate cancer. Given the limited field of view of the surgical site in RALRP, several groups have proposed the integration of transrectal ultrasound (TRUS) imaging in the surgical workflow to assist with accurate resection of the prostate and the sparing of the neurovascular bundles (NVBs). We previously introduced a robotic TRUS manipulator and a method for automatically tracking da Vinci surgical instruments with the TRUS imaging plane, in order to facilitate the integration of intraoperative TRUS in RALRP. Rapid and automatic registration of the kinematic frames of the da Vinci surgical system and the robotic TRUS probe manipulator is a critical component of the instrument tracking system. In this paper, we propose a fully automatic registration technique based on automatic 3-D TRUS localization of robot instrument tips pressed against the air-tissue boundary anterior to the prostate. The detection approach uses a multiscale filtering technique to identify and localize surgical instrument tips in the TRUS volume, and could also be used to detect other surface fiducials in 3-D ultrasound. Experiments have been performed using a tissue phantom and two ex vivo tissue samples to show the feasibility of the proposed methods. Also, an initial in vivo evaluation of the system has been carried out on a live anaesthetized dog with a da Vinci Si surgical system and a target registration error (defined as the root mean square distance of corresponding points after registration) of 2.68 mm has been achieved. Results show this method's accuracy and consistency for automatic registration of TRUS images to the da Vinci surgical system.

  11. [da Vinci surgical system].

    Science.gov (United States)

    Watanabe, Gou; Ishikawa, Norihiro

    2014-07-01

    The da Vinci surgical system was developed by Intuitive Surgical Inc. in the United States as an endoscopic surgical device to assist remote control surgeries. In 1998, the Da Vinci system was first used for cardiothoracic procedures. Currently a combination of robot-assisted internal thoracic artery harvest together with coronary artery bypass grafting (CABG) through a mini-incision (ThoraCAB) or totally endoscopic procedures including anastomoses under robotic assistance (TECAB) are being conducted for the treatment of coronary artery diseases. With the recent advances in catheter interventions, hybrid procedures combining catheter intervention with ThoraCAB or TECAB are anticipated in the future.On the other hand, with the decrease in number of coronary artery bypass surgeries, the share of valvular surgeries is expected to increase in the future. Among them, mitral valvuloplasty for mitral regurgitation is anticipated to be conducted mainly by low-invasive procedures, represented by minimally invasive cardiac surgery( MICS) and robot-assisted surgery. Apart from the intrinsic good surgical view, robotic-assisted systems offer additional advantages of the availability of an amplified view and the easy to observe the mitral valve in the physiological position. Thus, robotic surgical surgeries that make complicated procedures easier are expected to accomplish further developments in the future. Furthermore, while the number of surgeries for atrial septal defects has decreased dramatically following the widespread use of Amplatzer septal occluder, robotic surgery may become a good indication for cases in which the Amplatzer device is not indicated. In Japan, clinical trial of the da Vinci robotic system for heart surgeries has been completed. Statutory approval of the da Vinci system for mitral regurgitation and atrial septal defects is anticipated in the next few years.

  12. Intraoperative ultrasound control of surgical margins during partial nephrectomy.

    Science.gov (United States)

    Alharbi, Feras M; Chahwan, Charles K; Le Gal, Sophie G; Guleryuz, Kerem M; Tillou, Xavier P; Doerfler, Arnaud P

    2016-01-01

    To evaluate a simple and fast technique to ensure negative surgical margins on partial nephrectomies, while correlating margin statuses with the final pathology report. This study was conducted for patients undergoing partial nephrectomy (PN) with T1-T2 renal tumors from January 2010 to the end of December 2015. Before tumor removal, intraoperative ultrasound (US) localization was performed. After tumor removal and before performing hemostasis of the kidney, the specimens were placed in a saline solution and a US was performed to evaluate if the tumor's capsule were intact, and then compared to the final pathology results. In 177 PN(s) (147 open procedures and 30 laparoscopic procedures) were performed on 147 patients. Arterial clamping was done for 32 patients and the mean warm ischemia time was 19 ± 6 min. The mean US examination time was 41 ± 7 s. The US analysis of surgical margins was negative in 172 cases, positive in four, and in only one case it was not possible to conclude. The final pathology results revealed one false positive surgical margin and one false negative surgical margin, while all other margins were in concert with US results. The mean tumor size was 3.53 ± 1.43 cm, and the mean surgical margin was 2.8 ± 1.5 mm. The intraoperative US control of resection margins in PN is a simple, efficient, and effective method for ensuring negative surgical margins with a small increase in warm ischemia time and can be conducted by the operating urologist.

  13. Ultrasound-mediated nail drug delivery system.

    Science.gov (United States)

    Abadi, Danielle; Zderic, Vesna

    2011-12-01

    A novel ultrasound-mediated drug delivery system has been developed for treatment of a nail fungal disorder (onychomycosis) by improving delivery to the nail bed using ultrasound to increase the permeability of the nail. The slip-in device consists of ultrasound transducers and drug delivery compartments above each toenail. The device is connected to a computer, where a software interface allows users to select their preferred course of treatment. In in vitro testing, canine nails were exposed to 3 energy levels (acoustic power of 1.2 W and exposure durations of 30, 60, and 120 seconds). A stereo -microscope was used to determine how much of a drug-mimicking compound was delivered through the nail layers by measuring brightness on the cross section of each nail tested at each condition, where brightness level decreases coincide with increases in permeability. Each of the 3 energy levels tested showed statistical significance when compared to the control (P permeability factor of 1.3 after 30 seconds of exposure, 1.3 after 60 seconds, and 1.5 after 120 seconds, where a permeability factor of 1 shows no increase in permeability. Current treatments for onychomycosis include systemic, topical, and surgical. Even when used all together, these treatments typically take a long time to result in nail healing, thus making this ultrasound-mediated device a promising alternative.

  14. Towards Safe Robotic Surgical Systems

    DEFF Research Database (Denmark)

    Sloth, Christoffer; Wisniewski, Rafael

    2015-01-01

    A proof of safety is paramount for an autonomous robotic surgical system to ensure that it does not cause trauma to patients. However, a proof of safety is rarely constructed, as surgical systems are too complex to be dealt with by most formal verification methods. In this paper, we design...... a controller for motion compensation in beating-heart surgery, and prove that it is safe, i.e., the surgical tool is kept within an allowable distance and orientation of the heart. We solve the problem by simultaneously finding a control law and a barrier function. The motion compensation system is simulated...

  15. Surgical repair of bilateral levator ani muscles with ultrasound guidance.

    Science.gov (United States)

    Rostaminia, Ghazaleh; Shobeiri, S Abbas; Quiroz, Lieschen H

    2013-07-01

    Separation of the levator ani muscles from pubic bone is a common major levator trauma that may occur in vaginal delivery and is associated with pelvic floor dysfunctions. We describe a novel ultrasound-guided technique to repair these muscles. A 33-year-old woman presented with a history of difficult vaginal delivery and complaint of numbness and weakness of the vagina. In evaluation, bilateral levator defects were diagnosed by physical examination, three-dimensional endovaginal ultrasound, and magnetic resonance imaging. With ultrasound guidance the detached ends of muscles were tagged and sutured to their insertion points at the pubic bone. The patient's normal anatomy was restored with the return to normal pelvic floor tone. A follow-up ultrasound showed restored levator anatomy at 3 months.

  16. Active ultrasound pattern injection system (AUSPIS for interventional tool guidance.

    Directory of Open Access Journals (Sweden)

    Xiaoyu Guo

    Full Text Available Accurate tool tracking is a crucial task that directly affects the safety and effectiveness of many interventional medical procedures. Compared to CT and MRI, ultrasound-based tool tracking has many advantages, including low cost, safety, mobility and ease of use. However, surgical tools are poorly visualized in conventional ultrasound images, thus preventing effective tool tracking and guidance. Existing tracking methods have not yet provided a solution that effectively solves the tool visualization and mid-plane localization accuracy problem and fully meets the clinical requirements. In this paper, we present an active ultrasound tracking and guiding system for interventional tools. The main principle of this system is to establish a bi-directional ultrasound communication between the interventional tool and US imaging machine within the tissue. This method enables the interventional tool to generate an active ultrasound field over the original imaging ultrasound signals. By controlling the timing and amplitude of the active ultrasound field, a virtual pattern can be directly injected into the US machine B mode display. In this work, we introduce the time and frequency modulation, mid-plane detection, and arbitrary pattern injection methods. The implementation of these methods further improves the target visualization and guiding accuracy, and expands the system application beyond simple tool tracking. We performed ex vitro and in vivo experiments, showing significant improvements of tool visualization and accurate localization using different US imaging platforms. An ultrasound image mid-plane detection accuracy of ±0.3 mm and a detectable tissue depth over 8.5 cm was achieved in the experiment. The system performance is tested under different configurations and system parameters. We also report the first experiment of arbitrary pattern injection to the B mode image and its application in accurate tool tracking.

  17. Active ultrasound pattern injection system (AUSPIS) for interventional tool guidance.

    Science.gov (United States)

    Guo, Xiaoyu; Kang, Hyun-Jae; Etienne-Cummings, Ralph; Boctor, Emad M

    2014-01-01

    Accurate tool tracking is a crucial task that directly affects the safety and effectiveness of many interventional medical procedures. Compared to CT and MRI, ultrasound-based tool tracking has many advantages, including low cost, safety, mobility and ease of use. However, surgical tools are poorly visualized in conventional ultrasound images, thus preventing effective tool tracking and guidance. Existing tracking methods have not yet provided a solution that effectively solves the tool visualization and mid-plane localization accuracy problem and fully meets the clinical requirements. In this paper, we present an active ultrasound tracking and guiding system for interventional tools. The main principle of this system is to establish a bi-directional ultrasound communication between the interventional tool and US imaging machine within the tissue. This method enables the interventional tool to generate an active ultrasound field over the original imaging ultrasound signals. By controlling the timing and amplitude of the active ultrasound field, a virtual pattern can be directly injected into the US machine B mode display. In this work, we introduce the time and frequency modulation, mid-plane detection, and arbitrary pattern injection methods. The implementation of these methods further improves the target visualization and guiding accuracy, and expands the system application beyond simple tool tracking. We performed ex vitro and in vivo experiments, showing significant improvements of tool visualization and accurate localization using different US imaging platforms. An ultrasound image mid-plane detection accuracy of ±0.3 mm and a detectable tissue depth over 8.5 cm was achieved in the experiment. The system performance is tested under different configurations and system parameters. We also report the first experiment of arbitrary pattern injection to the B mode image and its application in accurate tool tracking.

  18. Bedside ultrasound in the diagnosis of uterine rupture following surgical abortion.

    Science.gov (United States)

    Derr, Charlotte; Henry, Melinda

    2013-04-01

    Reports of uterine rupture following surgical abortion are rare but may result in hemorrhage, sepsis, and even death. In this unique case, we describe how a transabdominal pelvic ultrasound performed at the bedside by an emergency department physician identified uterine rupture with retained products of conception and led to an emergent laparotomy and hysterectomy. This case illustrates how bedside ultrasound may be used in patients presenting with abdominopelvic pain following surgical abortion to shorten the time to definitive treatment and ultimately lower the morbidity and mortality associated with a diagnosis of life-threatening uterine rupture.

  19. Intraoperative ultrasound control of surgical margins during partial nephrectomy

    Directory of Open Access Journals (Sweden)

    Feras M Alharbi

    2016-01-01

    Conclusions: The intraoperative US control of resection margins in PN is a simple, efficient, and effective method for ensuring negative surgical margins with a small increase in warm ischemia time and can be conducted by the operating urologist.

  20. Anaesthesia Management of Surgical Treatment for Atrial Fibrillation using Ultrasound Energy

    Directory of Open Access Journals (Sweden)

    Vaijayanti N Gadre

    2013-03-01

    Full Text Available Atrial Fibrillation is commonly associated with Mitral Valve Disease. Valve replacement, associated with surgical correction of atrial fibrillation, is considered as a definitive cure for such condition. In this article, anaesthesia management of four cases is discussed where AF was surgically treated using Ultrasound energy. Patients were diagnosed cases of Mitral Stenosis and/or Regurgitation. Procedure for ablation of AF was done after midline sternotomy on beating heart followed by Mitral valve replacement on Cardio-Pulmonary bypass. Various surgical methods of treating AF are also discussed.

  1. Augmented reality surgical navigation with ultrasound-assisted registration for pedicle screw placement: a pilot study.

    Science.gov (United States)

    Ma, Longfei; Zhao, Zhe; Chen, Fang; Zhang, Boyu; Fu, Ligong; Liao, Hongen

    2017-08-05

    We present a novel augmented reality (AR) surgical navigation system based on ultrasound-assisted registration for pedicle screw placement. This system provides the clinically desired targeting accuracy and reduces radiation exposure. Ultrasound (US) is used to perform registration between preoperative computed tomography (CT) images and patient, and the registration is performed by least-squares fitting of these two three-dimensional (3D) point sets of anatomical landmarks taken from US and CT images. An integral videography overlay device is calibrated to accurately display naked-eye 3D images for surgical navigation. We use a 3.0-mm Kirschner wire (K-wire) instead of a pedicle screw in this study, and the K-wire is calibrated to obtain its orientation and tip location. Based on the above registration and calibration, naked-eye 3D images of the planning path and the spine are superimposed onto patient in situ using our AR navigation system. Simultaneously, a 3D image of the K-wire is overlaid accurately on the real one to guide the insertion procedure. The targeting accuracy is evaluated postoperatively by performing a CT scan. An agar phantom experiment was performed. Eight K-wires were inserted successfully after US-assisted registration, and the mean targeting error and angle error were 3.35 mm and [Formula: see text], respectively. Furthermore, an additional sheep cadaver experiment was performed. Four K-wires were inserted successfully. The mean targeting error was 3.79 mm and the mean angle error was [Formula: see text], and US-assisted registration yielded better targeting results than skin markers-based registration (targeting errors: 2.41 vs. 5.18 mm, angle errors: [Formula: see text] vs. [Formula: see text]. Experimental outcomes demonstrate that the proposed navigation system has acceptable targeting accuracy. In particular, the proposed navigation method reduces repeated radiation exposure to the patient and surgeons. Therefore, it has promising

  2. Ultrasound and MRI predictors of surgical bowel resection in pediatric Crohn disease.

    Science.gov (United States)

    Rosenbaum, Daniel G; Conrad, Maire A; Biko, David M; Ruchelli, Eduardo D; Kelsen, Judith R; Anupindi, Sudha A

    2017-01-01

    Imaging predictors for surgery in children with Crohn disease are lacking. To identify imaging features of the terminal ileum on short-interval bowel ultrasound (US) and MR enterography (MRE) in children with Crohn disease requiring surgical bowel resection and those managed by medical therapy alone. This retrospective study evaluated patients 18 years and younger with Crohn disease undergoing short-interval bowel US and MRE (within 2 months of one another), as well as subsequent ileocecectomy or endoscopy within 3 months of imaging. Appearance of the terminal ileum on both modalities was compared between surgical patients and those managed with medical therapy, with the following parameters assessed: bowel wall thickness, mural stratification, vascularity, fibrofatty proliferation, abscess, fistula and stricture on bowel US; bowel wall thickness, T2 ratio, enhancement pattern, mesenteric edema, fibrofatty proliferation, abscess, fistula and stricture on MRE. A two-sided t-test was used to compare means, a Mann-Whitney U analysis was used for non-parametric parameter scores, and a chi-square or two-sided Fisher exact test compared categorical variables. Imaging findings in surgical patients were correlated with location-matched histopathological scores of inflammation and fibrosis using a scoring system adapted from the Simple Endoscopic Score for Crohn Disease, and a Spearman rank correlation coefficient was used to compare inflammation and fibrosis on histopathology. Twenty-two surgical patients (mean age: 16.5 years; male/female: 13/9) and 20 nonsurgical patients (mean age: 14.8; M/F: 8/12) were included in the final analysis. On US, the surgical group demonstrated significantly increased mean bowel wall thickness (6.1 mm vs. 4.7 mm for the nonsurgical group; P = 0.01), loss of mural stratification (odds ratio [OR] = 6.3; 95% confidence interval [CI]: 1.4-28.4; P = 0.02) and increased fibrofatty proliferation (P = 0.04). On MRE, the

  3. Ultrasound and MRI predictors of surgical bowel resection in pediatric Crohn disease

    Energy Technology Data Exchange (ETDEWEB)

    Rosenbaum, Daniel G. [NewYork-Presbyterian Hospital/Weill Cornell Medicine, Division of Pediatric Radiology, New York, NY (United States); Conrad, Maire A.; Kelsen, Judith R. [The Children' s Hospital of Philadelphia, Division of Gastroenterology, Hepatology and Nutrition, Philadelphia, PA (United States); Biko, David M.; Anupindi, Sudha A. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Ruchelli, Eduardo D. [The Children' s Hospital of Philadelphia, Division of Anatomic Pathology, Philadelphia, PA (United States)

    2017-01-15

    Imaging predictors for surgery in children with Crohn disease are lacking. To identify imaging features of the terminal ileum on short-interval bowel ultrasound (US) and MR enterography (MRE) in children with Crohn disease requiring surgical bowel resection and those managed by medical therapy alone. This retrospective study evaluated patients 18 years and younger with Crohn disease undergoing short-interval bowel US and MRE (within 2 months of one another), as well as subsequent ileocecectomy or endoscopy within 3 months of imaging. Appearance of the terminal ileum on both modalities was compared between surgical patients and those managed with medical therapy, with the following parameters assessed: bowel wall thickness, mural stratification, vascularity, fibrofatty proliferation, abscess, fistula and stricture on bowel US; bowel wall thickness, T2 ratio, enhancement pattern, mesenteric edema, fibrofatty proliferation, abscess, fistula and stricture on MRE. A two-sided t-test was used to compare means, a Mann-Whitney U analysis was used for non-parametric parameter scores, and a chi-square or two-sided Fisher exact test compared categorical variables. Imaging findings in surgical patients were correlated with location-matched histopathological scores of inflammation and fibrosis using a scoring system adapted from the Simple Endoscopic Score for Crohn Disease, and a Spearman rank correlation coefficient was used to compare inflammation and fibrosis on histopathology. Twenty-two surgical patients (mean age: 16.5 years; male/female: 13/9) and 20 nonsurgical patients (mean age: 14.8; M/F: 8/12) were included in the final analysis. On US, the surgical group demonstrated significantly increased mean bowel wall thickness (6.1 mm vs. 4.7 mm for the nonsurgical group; P = 0.01), loss of mural stratification (odds ratio [OR] = 6.3; 95% confidence interval [CI]: 1.4-28.4; P = 0.02) and increased fibrofatty proliferation (P = 0.04). On MRE, the surgical group showed

  4. Phased array based ultrasound scanning system development

    Science.gov (United States)

    Sagdiev, R. K.; Denisov, E. S.; Evdokimov, Yu K.; Fazlyyyakhmatov, M. G.; Kashapov, N. F.

    2014-12-01

    Multichannel ultrasound scanning system based on phased arrays development is presented in this paper. Substantiation of system parameters is presented. The description of block diagram and hardware development is presented. The combination of the self-developed receiving and a transmitting units and commercially available FPGA unit and Personal Computer can solve our scientific goals, while providing a relatively low device cost.

  5. Predictive Value of Conventional Ultrasound and Contrast-Enhanced Ultrasound in Early Recurrence of Hepatocellular Carcinoma after Surgical Resection.

    Science.gov (United States)

    Wang, Yibin; Liao, Jintang; Qi, Wenjun; Xie, Lulu; Li, Yueyi

    2016-05-01

    The goals of the work described here were to study the pre-operative risk factors associated with early recurrence (ER) of hepatocellular carcinoma (HCC) after surgical resection and discuss the value of conventional ultrasound (US) and contrast-enhanced ultrasound (CEUS) in predicting ER of HCC, so as to provide more information for optimizing clinical treatment and improving prognosis. A retrospective analysis was conducted on 59 patients who underwent both US and CEUS examinations pre-operatively and surgical resection for HCC between December 2010 and January 2014 in our hospital. The patients' clinical data, laboratory examination data and ultrasonic imaging diagnostic data were collected. Univariate analysis and logistic regression analysis were performed to determine the independent risk factors for ER of HCC after surgical resection. Diagnostic values of independent risk factors in predicting ER were further evaluated. The 59 patients were divided into the ER group (27 cases) and ER-free group (32 cases). There were no significant differences in age and sex between the two groups (p > 0.05). Univariate analysis revealed that differences in pre-operative serum α-fetoprotein level ≥400 ng/mL (p = 0.008), tumor diameter ≥5 cm (p = 0.012), macroscopic vascular invasion (p = 0.040), "fast wash-out" enhancement pattern (p = 0.006) and inhomogeneous distribution of contrast agent (p = 0.031) statistically significantly differed between the two groups. Logistic regression analysis indicated that pre-operative serum AFP level ≥400 ng/mL (p = 0.024), tumor diameter ≥5 cm (p = 0.042) and "fast wash-out" enhancement pattern (p = 0.009) were independent risk factors for ER of HCC; macrovascular invasion (p = 0.095) and inhomogeneous distribution of contrast agent (p = 0.628) did not statistically significantly differ between two groups (p = 0.628). Predictive values of the independent risk factors were further evaluated. The sensitivity of a "fast wash

  6. Development of AR Surgical Navigation Systems for Multiple Surgical Regions.

    Science.gov (United States)

    Suzuki, Naoki; Hattori, Asaki; Iimura, Jiro; Otori, Nobuyoshi; Onda, Shinji; Okamoto, Tomoyoshi; Yanaga, Katsuhiko

    2014-01-01

    The purpose of our research is to develop surgical navigation systems to enhance surgical safety. Our systems make use of augmented reality technology to superimpose, on the surgery screen on a real time basis, patients' organ models reconstructed in 3D from their X-ray CT data taken before surgery. By doing so, the systems display anatomical risk materials, tumors and blood vessels which surgeons cannot see with their naked eyes. This will in turn lead to surgeons intuitively grasping the inner structures of the operational fields. We so far have been developing navigation systems that can conduct surgeries in various fields. The basic structure of the navigation systems are the same. The navigation systems uses different peripheral equipment and different methods to display navigation images which best meet the demands of each type of surgery. In this thesis, we report on our navigation systems for 2 types of surgery - endoscopic sinus surgery and hepatobilialy-pancreatic surgery.

  7. Plunging ranulas: high-resolution ultrasound for diagnosis and surgical management

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Prabha [Middlemore Hospital, Counties Manakau, Department of Radiology, P.O. Box 93311, Otahuhu, Auckland (New Zealand); Jain, Ravi [Waikato Hospital, Department of Plastic Surgery, Hamilton (New Zealand); Morton, Randall P.; Ahmad, Zahoor [Middlemore Hospital, Counties Manakau, Department of ENT Surgery, P.O. Box 93311, Otahuhu, Auckland (New Zealand)

    2010-06-15

    We see a high incidence of plunging ranulas, particularly in Maori and Polynesian populations. We have investigated the usefulness of ultrasound in the diagnosis and management of plunging ranulas and present our findings. Thirty-three new cases were examined over 4 years (June 2004 to October 2008). High-resolution ultrasound was very successful in determining the extent of the plunging ranula, confirming the cystic nature of the lesion, assessing the status of the mylohyoid muscle (a defect demonstrated in 100% of our cases) and evaluating the sublingual gland for rupture or herniation. Correlation with surgical findings was available for 30 cases. There was excellent ultrasonographic and surgical correlation, particularly with respect to submandibular space cystic collection (29 of 30 cases, 96.7%) and mylohyoid defects (27 of 30 cases, 90%). With the considerations of cost, accessibility and the fact that many of our patients are young (median of 20 years), ultrasound is recommended as the preferred examination for plunging ranula. (orig.)

  8. Modification of Food Systems by Ultrasound

    Directory of Open Access Journals (Sweden)

    L. M. Carrillo-Lopez

    2017-01-01

    Full Text Available This review describes the mechanism, operation, and recent potential applications of ultrasound in various food systems, as well as the physical and chemical effects of ultrasound treatments on the conservation and modification of different groups of food. Acoustic energy has been recognized as an emerging technology with great potential for applications in the food industry. The phenomenon of acoustic cavitation, which modifies the physical, chemical, and functional properties of food, can be used to improve existing processes and to develop new ones. The combination of ultrasonic energy with a sanitizing agent can improve the effect of microbial reduction in foods and, thereby, their quality. Finally, it is concluded that the use of ultrasound in food is a very promising area of research; however, more research is still needed before applying this technology in a wider range of industrial sectors.

  9. Surgical treatment of multiple symmetric lipomatosis with ultrasound-assisted liposuction.

    Science.gov (United States)

    Bassetto, Franco; Scarpa, Carlotta; De Stefano, Fabio; Busetto, Luca

    2014-11-01

    Multiple symmetric lipomatosis (MSL) is a rare disease of unknown etiology, characterized by the presence of multiple, symmetrical, noncapsulated lipomas, mostly in the neck and upper trunk. To date, there is no effective medical treatment of MSL. Surgical treatment is based on 2 options, namely, lipectomy and/or liposuction. In this retrospective study, we compare traditional lipectomy with ultrasound-assisted liposuction. Our initial experience demonstrates that the ultrasound-assisted liposuction procedure can be applied to patients with MSL, allowing simultaneous treatment of multiple areas in a single session and the removal of a substantial amount of fat, thus improving aesthetic results. If lipomas are circumscribed and isolated, traditional lipectomy is probably to be preferred.

  10. Phyllodes tumor diagnosed after ultrasound-guided vacuum-assisted excision: should it be followed by surgical excision?

    Science.gov (United States)

    Youk, Ji Hyun; Kim, Hana; Kim, Eun-Kyung; Son, Eun Ju; Kim, Min Jung; Kim, Jeong-Ah

    2015-03-01

    Our aim was to retrospectively evaluate the results of ultrasound (US)-guided vacuum-assisted excision (US-VAE) of phyllodes tumors (PTs). A total of 41 PTs diagnosed at US-VAE followed by surgery (n = 27) or at least 2 y of US monitoring (n = 14) were included. By comparison of US-VAE pathology with surgical histology or follow-up US results, cases were divided into upgraded (malignant) and non-upgraded (benign) groups. These two groups were compared with respect to clinical, procedural and US features. Among 27 surgical cases, 2 (8.7%) of 23 benign PTs were upgraded to malignant PTs. The Breast Imaging Reporting and Data System category was retrospectively assigned as 4a (50%) or 4b (50%) in the upgraded group (n = 2) and 3 (64%) or 4a (36%) in the non-upgraded group (n = 39) (p = 0.018). Residual tumor was observed at the site of US-VAE in 15 of 27 surgical cases and 0 of 14 US follow-up cases (36.6%, 15/41). Given the rates of upgrade to malignancy (8.7%) and residual tumor (36.6%), PTs diagnosed after US-VAE should be surgically excised.

  11. Sampling system for in vivo ultrasound images

    DEFF Research Database (Denmark)

    Jensen, Jorgen Arendt; Mathorne, Jan

    1991-01-01

    Newly developed algorithms for processing medical ultrasound images use the high frequency sampled transducer signal. This paper describes demands imposed on a sampling system suitable for acquiring such data and gives details about a prototype constructed. It acquires full clinical images...

  12. New prototype neuronavigation system based on preoperative imaging and intraoperative freehand ultrasound: system description and validation.

    Science.gov (United States)

    Mercier, Laurence; Del Maestro, Rolando F; Petrecca, Kevin; Kochanowska, Anna; Drouin, Simon; Yan, Charles X B; Janke, Andrew L; Chen, Sean Jy-Shyang; Collins, D Louis

    2011-07-01

    The aim of this report is to present IBIS (Interactive Brain Imaging System) NeuroNav, a new prototype neuronavigation system that has been developed in our research laboratory over the past decade that uses tracked intraoperative ultrasound to address surgical navigation issues related to brain shift. The unique feature of the system is its ability, when needed, to improve the initial patient-to-preoperative image alignment based on the intraoperative ultrasound data. Parts of IBIS Neuronav source code are now publicly available on-line. Four aspects of the system are characterized in this paper: the ultrasound probe calibration, the temporal calibration, the patient-to-image registration and the MRI-ultrasound registration. In order to characterize its real clinical precision and accuracy, the system was tested in a series of adult brain tumor cases. Three metrics were computed to evaluate the precision and accuracy of the ultrasound calibration. 1) Reproducibility: 1.77 mm and 1.65 mm for the bottom corners of the ultrasound image, 2) point reconstruction precision 0.62-0.90 mm: and 3) point reconstruction accuracy: 0.49-0.74 mm. The temporal calibration error was estimated to be 0.82 ms. The mean fiducial registration error (FRE) of the homologous-point-based patient-to-MRI registration for our clinical data is 4.9 ± 1.1 mm. After the skin landmark-based registration, the mean misalignment between the ultrasound and MR images in the tumor region is 6.1 ± 3.4 mm. The components and functionality of a new prototype system are described and its precision and accuracy evaluated. It was found to have an accuracy similar to other comparable systems in the literature.

  13. Musculoskeletal Ultrasound

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Ultrasound - Musculoskeletal Ultrasound imaging uses sound waves to produce ... Ultrasound Imaging of the Musculoskeletal System? What is Ultrasound Imaging of the Musculoskeletal System? Ultrasound is safe ...

  14. Motion tracing system for ultrasound guided HIFU

    Science.gov (United States)

    Xiao, Xu; Jiang, Tingyi; Corner, George; Huang, Zhihong

    2017-03-01

    One main limitation in HIFU treatment is the abdominal movement in liver and kidney caused by respiration. The study has set up a tracking model which mainly compromises of a target carrying box and a motion driving balloon. A real-time B-mode ultrasound guidance method suitable for tracking of the abdominal organ motion in 2D was established and tested. For the setup, the phantoms mimicking moving organs are carefully prepared with agar surrounding round-shaped egg-white as the target of focused ultrasound ablation. Physiological phantoms and animal tissues are driven moving reciprocally along the main axial direction of the ultrasound image probe with slightly motion perpendicular to the axial direction. The moving speed and range could be adjusted by controlling the inflation and deflation speed and amount of the balloon driven by a medical ventilator. A 6-DOF robotic arm was used to position the focused ultrasound transducer. The overall system was trying to estimate to simulate the actual movement caused by human respiration. HIFU ablation experiments using phantoms and animal organs were conducted to test the tracking effect. Ultrasound strain elastography was used to post estimate the efficiency of the tracking algorithms and system. In moving state, the axial size of the lesion (perpendicular to the movement direction) are averagely 4mm, which is one third larger than the lesion got when the target was not moving. This presents the possibility of developing a low-cost real-time method of tracking organ motion during HIFU treatment in liver or kidney.

  15. Ultrasound

    Science.gov (United States)

    Ultrasound is a type of imaging. It uses high-frequency sound waves to look at organs and ... liver, and other organs. During pregnancy, doctors use ultrasound to view the fetus. Unlike x-rays, ultrasound ...

  16. Ultrasound systems for blood velocity estimation

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    1998-01-01

    color image of velocity at up to 20 to 60 frames a second. Both measurements are performedby repeatedly pulsing in the same direction and then usethe correlation from pulse to pulse to determine the velocity.The paper gives a simple model for the interactionbetween the ultrasound and the moving blood......Medical ultrasound scanners can be used both for displayinggray-scale images of the anatomy and for visualizing theblood flow dynamically in the body.The systems can interrogate the flow at a single position in the bodyand there find the velocity distribution over time. They can also show adynamic....... The calculation of the velocity distribution is then explainedalong with the different physical effects influencing the estimation.The estimation of mean velocities using auto- andcross-correlation for color flow mapping is also described....

  17. Computerized ultrasound risk evaluation system

    Science.gov (United States)

    Duric, Nebojsa; Littrup, Peter J.; Holsapple, III, Earle; Barter, Robert Henry; Moore, Thomas L.; Azevedo, Stephen G.; Ferguson, Sidney W.

    2007-10-23

    A method and system for examining tissue are provided in which the tissue is maintained in a position so that it may be insonified with a plurality of pulsed spherical or cylindrical acoustic waves. The insonifying acoustic waves are scattered by the tissue so that scattered acoustic radiation including a mix of reflected and transmitted acoustic waves is received. A representation of a portion of the tissue is then derived from the received scattered acoustic radiation.

  18. Method and system to synchronize acoustic therapy with ultrasound imaging

    Science.gov (United States)

    Owen, Neil (Inventor); Bailey, Michael R. (Inventor); Hossack, James (Inventor)

    2009-01-01

    Interference in ultrasound imaging when used in connection with high intensity focused ultrasound (HIFU) is avoided by employing a synchronization signal to control the HIFU signal. Unless the timing of the HIFU transducer is controlled, its output will substantially overwhelm the signal produced by ultrasound imaging system and obscure the image it produces. The synchronization signal employed to control the HIFU transducer is obtained without requiring modification of the ultrasound imaging system. Signals corresponding to scattered ultrasound imaging waves are collected using either the HIFU transducer or a dedicated receiver. A synchronization processor manipulates the scattered ultrasound imaging signals to achieve the synchronization signal, which is then used to control the HIFU bursts so as to substantially reduce or eliminate HIFU interference in the ultrasound image. The synchronization processor can alternatively be implemented using a computing device or an application-specific circuit.

  19. Application of high-frequency ultrasound for the detection of surgical anatomy in the rodent abdomen.

    Science.gov (United States)

    Chen, J Y; Chen, H L; Wu, S H; Tsai, T C; Lin, M F; Yen, C C; Hsu, W H; Chen, W; Chen, C M

    2012-02-01

    Rats are used extensively in abdominal disease research. To monitor disease progress in vivo, high-frequency ultrasound (HFU) can be a powerful tool for obtaining high-resolution images of biological tissues. However, there is a paucity of data regarding the correlation between rat anatomy and corresponding HFU images. Twenty-four adult male Sprague-Dawley (SD) rats underwent abdominal scans using HFU (40 MHz) surgical procedures to identify abdominal organs and major vessels as well as in situ scanning to confirm the imaging results. The results were compared with those of human abdominal organs in ultrasonographic scans. The rat liver, paired kidneys, stomach, intestines, and major blood vessels were identified by HFU and the ultrasonic morphologies of the liver and kidneys showed clear differences between rats and humans. Clinically relevant anatomical structures were identified using HFU imaging of the rat abdomen, and these structures were compared with the corresponding structures in humans. Increased knowledge with regard to identifying the anatomy of rat abdominal organs by ultrasound will allow scientists to conduct more detailed intra-abdominal research in rodents.

  20. Ultrasound-fluoroscopy guided access to the intrarenal excretory system.

    Science.gov (United States)

    Montanari, E; Serrago, M; Esposito, N; Rocco, B; Kartalas-Goumas, I; Del Nero, A; Zanetti, G; Trinchieri, A; Pisani, E

    1999-01-01

    The access to the collecting system can be performed under fluoroscopy computerized tomography, ultrasonographic, mixed ultrasonographic and fluoroscopic guidance. In this paper the creation of a percutaneous transparenchymal ultrasound-fluoroscopy guided access to the intrarenal collecting system completely performed by urologist for different purposes is presented. In five years 297 patients underwent 330 percutaneous kidney accesses to perform derivative nephrostomies (217 pts), percutaneous nephrolithotomies (37 pts), antegrade ureteral manoeuvres (34 pts), antegrade endopyelotomies (7 pts), transitional cell carcinoma of the upper tract resection (2 pts). 11 patients out of these had a percutaneous kidney access in a transplanted kidney. The percutaneous access was successful in 98% of the attemps. A posterior calyx of the lower group (74%), of the medium group (25%) or of the upper group (1%) was accessed. In 73 accesses the mean target calyx diameter was 12.8 mm (range 5-45 mm), the mean operative time 5.4 minutes and the mean fluoroscopy time 5.1 seconds. In 84.5% of the patients the access was performed under local anesthesia when a dilation of the tract was not required. Gross haematuria was observed in 3.9% of the accesses and an arterial lesion treated by embolization in 0.9% of the accesses. Blood transfusion was required in 0.3% of the patients. The ultrasound-fluoroscopy guided access is at least as precise as the fluoroscopy guided one moreover it makes the procedure less invasive and it makes more precise the surgical planning.

  1. Field: A Program for Simulating Ultrasound Systems

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    1997-01-01

    A program for the simulation of ultrasound systems is presented.It is based on the Tupholme-Stepanishen method, and is fastbecause of the use of a far-field approximation. Any kind oftransducer geometry and excitation can be simulated, and bothpulse-echo and continuous wave fields can be calculated...... for bothtransmit and pulse-echo. Dynamic apodization and focusing arehandled through time lines, and different focusingschemes can be simulated. The versatility of the program isensured by interfacing it to Matlab. All routines are calleddirectly from Matlab, and all Matlab features can be used. Thismakes...

  2. Automated kinematic generator for surgical robotic systems.

    Science.gov (United States)

    Jung, David L; Dixon, Warren E; Pin, François G

    2004-01-01

    Unlike traditional assembly line robotic systems that have a fixed kinematic structure associated with a single tool for a structured task, next-generation robotic surgical assist systems will be required to use an array of end-effector tools. Once a robot is connected with a tool, the kinematic equations of motion are altered. Given the need to accommodate evolving surgical challenges and to alleviate the restrictions imposed by the confined minimally invasive environment, new surgical tools may resemble small flexible snakes rather than rigid, cable driven instruments. Connecting to these developing articulated tools will significantly alter the overall kinematic structure of a robotic system. In this paper we present a technique for real-time automated generation and evaluation of manipulator kinematic equations that exhibits the combined advantages of existing methods-speed and flexibility to kinematic change--without their disadvantages.

  3. [Focused surgical bedside ultrasound: E-FAST (focused assessment with sonography in trauma) - abdominal aortic aneurysm - cholecystolithiasis - acute appendicitis].

    Science.gov (United States)

    Studer, Maria; Studer, Peter

    2014-06-04

    Ultrasound is an easy to learn and highly efficient diagnostic tool to complete the clinical examination and improve bedside decision-making. In the trauma room, surgeons are often required to make a quick decision as to whether or not a patient needs an emergency intervention or whether further diagnostics are required. For this reason, education of surgeons in performing focused emergency ultrasound is pivotal. The goal of ICAN is to improve and expand the education of surgeons in Switzerland. This article provides a short review of the most frequent surgical pathologies encountered in the emergency room.

  4. Ultrasound Imaging of the Musculoskeletal System.

    Science.gov (United States)

    Cook, Cristi R

    2016-05-01

    Musculoskeletal ultrasound is a rapidly growing field within veterinary medicine. Ultrasound for musculoskeletal disorders has been commonly used in equine and human medicine and is becoming more commonly performed in small animal patients due to the increase in the recognition of soft tissue injuries. Ultrasound is widely available, cost-effective, but technically difficult to learn. Advantages of musculoskeletal ultrasound are the opposite limb is commonly used for comparison to evaluate symmetry of the tendinous structures and the ease of repeat examinations to assess healing. The article discusses the major areas of shoulder, stifle, iliopsoas, gastrocnemius, and musculoskeletal basics.

  5. Ultrasound guidance system for prostate biopsy

    Science.gov (United States)

    Hummel, Johann; Kerschner, Reinhard; Kaar, Marcus; Birkfellner, Wolfgang; Figl, Michael

    2017-03-01

    We designed a guidance system for prostate biopsy based on PET/MR images and 3D ultrasound (US). With our proposed method common inter-modal MR-US (or CT-US in case of PET/CTs) registration can be replaced by an intra-modal 3D/3D-US/US registration and an optical tracking system (OTS). On the pre-operative site, a PET/MR calibration allows to link both hybrid modalities with an abdominal 3D-US. On the interventional site, another abdominal 3D US is taken to merge the pre-operative images with the real-time 3D-US via 3D/3D-US/US registration. Finally, the images of a tracked trans-rectal US probe can be displayed with the pre-operative images by overlay. For PET/MR image fusion we applied a point-to-point registration between PET and OTS and MR and OTS, respectively. 3D/3D-US/US registration was evaluated for images taken in supine and lateral patient position. To enable table shifts between PET/MR and US image acquisition a table calibration procedure is presented. We found fiducial registration errors of 0.9 mm and 2.8 mm, respectively, with respect to the MR and PET calibration. A target registration error between MR and 3D US amounted to 1.4 mm. The registration error for the 3D/3D-US/US registration was found to be 3.7 mm. Furthermore, we have shown that ultrasound is applicable in an MR environment.

  6. Linear description of ultrasound imaging systems

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    These notes have been prepared for the international summer school on advanced ultrasound imaging sponsored by The Danish Research Academy. The notes should be read in conjunction with the notes prepared by Anderson and Trahey1. The intended audience is Ph.D. students working in medical ultrasound...

  7. FY1995 development of a endoscopic surgical system utilizing multi-modal functional images; 1995 nendo tashu kino gazo wo mochiiru teishinshu naishikyo shujutsu system no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-05-01

    The purpose of this study is to develop an endoscope system for neurosurgery that can provide not only conventional endoscopic images but also ultraviolet-visible spectra, fluorescence spectra, near infrared spectra, and ultra-soundimages of tissue aiming for real-time identification of pathological tissue. The system also incorporates surgical manipulator and devices such as micro forceps and laser surgical instruments for endoscopic image guided surgery. Surgical Manipulator should be a high performance and easy to operate surgical instrument as well as conventional surgical tools such as scissors and knife. Since living tissue deforms during surgical operation, pre-operative three dimensional information for registration of pathological tissue should be modified based on information obtained during surgery. Thus surgical manipulator should be operated under guidance of surgeon's observation. Consequently, surgical manipulator should have various types of imaging and measurement devices such as an endoscope and an ultrasound imaging probe at its end effectors. Based on this concept, a prototype of a new multi channel surgical manipulator system CM cube (CM3, Computer aided Micro Multichannel Manipulator) that has various types of imaging and measurement devices such as ultra-violet-visible camera for spectroscopic measurement, ultra-sound imaging probe, three dimensional endoscope, together with micro surgical instruments and laser surgical systems has been developed. Its performance was evaluated through in vitro/in vivo experiments and clinical application. (NEDO)

  8. An autotuning respiration compensation system based on ultrasound image tracking.

    Science.gov (United States)

    Kuo, Chia-Chun; Chuang, Ho-Chiao; Teng, Kuan-Ting; Hsu, Hsiao-Yu; Tien, Der-Chi; Wu, Chih-Jen; Jeng, Shiu-Chen; Chiou, Jeng-Fong

    2016-11-22

    The purpose of this study was to develop an ultrasound image tracking algorithm (UITA) for extracting the exact displacement of internal organs caused by respiratory motion. The program can track organ displacements in real time, and analyze the displacement signals associated with organ displacements via a respiration compensating system (RCS). The ultrasound imaging system is noninvasive and has a high spatial resolution and a high frame rate (around 32 frames/s), which reduces the radiation doses that patients receive during computed tomography and X-ray observations. This allows for the continuous noninvasive observation and compensation of organ displacements simultaneously during a radiation therapy session.This study designed a UITA for tracking the motion of a specific target, such as the human diaphragm. Simulated diaphragm motion driven by a respiration simulation system was observed with an ultrasound imaging system, and then the induced diaphragm displacements were calculated by our proposed UITA. These signals were used to adjust the gain of the RCS so that the amplitudes of the compensation signals were close to the target movements. The inclination angle of the ultrasound probe with respect to the surface of the abdomen affects the results of ultrasound image displacement tracking. Therefore, the displacement of the phantom was verified by a LINAC with different inclination-angle settings of the ultrasound probe. The experimental results indicate that the best inclination angle of the ultrasound probe is 40 degrees, since this results in the target displacement of the ultrasound images being close to the actual target motion. The displacement signals of the tracking phantom and the opposing displacement signals created by the RCS were compared to assess the positioning accuracy of our proposed ultrasound image tracking technique combined with the RCS.When the ultrasound probe was inclined by 40 degrees in simulated respiration experiments using sine

  9. Quantitative analysis with the optoacoustic/ultrasound system OPUS

    Science.gov (United States)

    Haisch, Christoph; Zell, Karin; Sperl, Jonathan; Vogel, Mika W.; Niessner, Reinhard

    2009-02-01

    The OPUS (Optoacoustic plus Ultrasound) system is a combination of a medical ultrasound scanner with a highrepetition rate, wavelength-tunable laser system and a suitable triggering interface to synchronize the laser and the ultrasound system. The pulsed laser generates an optoacoustic (OA), or photoacoustic (PA), signal which is detected by the ultrasound system. Alternatively, imaging in conventional ultrasound mode can be performed. Both imaging modes can be superimposed. The laser light is coupled into the tissue laterally, parallel to the ultrasound transducer, which does not require for any major modification to the transducer or the ultrasound beam forming. This was a basic requirement on the instrument, as the intention of the project was to establish the optoacoustic imaging modality as add-on to a conventional standard ultrasound instrument. We believe that this approach may foster the introduction of OA imaging as routine tool in medical diagnosis. Another key aspect of the project was to exploit the capabilities of OA imaging for quantitative analysis. The intention of the presented work is to summarize all steps necessary to extract the significant information from the PA raw data, which are required for the quantification of local absorber distributions. We show results of spatially resolved absorption measurements in scattering samples and a comparison of four different image reconstruction algorithms, regarding their influence on lateral resolution as well as on the signal to noise ratio for different sample depths and absorption values. The reconstruction algorithms are based on Fourier transformation, on a generalized 2D Hough transformation, on circular back-projection and the classical delay-and-sum approach which is implemented in most ultrasound scanners. Furthermore, we discuss the influence of a newly developed laser source, combining diode and flash lamp pumping. Compared to all-flash-lamp pumped systems it features a significantly higher

  10. Ultrasound

    Science.gov (United States)

    ... Saunders; 2014:chap 66. Cosgrove DO, Eckersley RJ, Harvey CJ, Lim A. Ultrasound. In: Adam A, Dixon AK, Gillard ... Northside Radiology Associates, Atlanta, GA. Also reviewed by David Zieve, MD, MHA, Isla Ogilvie, PhD, and the ...

  11. Evolution of autonomous and semi-autonomous robotic surgical systems: a review of the literature.

    Science.gov (United States)

    Moustris, G P; Hiridis, S C; Deliparaschos, K M; Konstantinidis, K M

    2011-12-01

    Autonomous control of surgical robotic platforms may offer enhancements such as higher precision, intelligent manoeuvres, tissue-damage avoidance, etc. Autonomous robotic systems in surgery are largely at the experimental level. However, they have also reached clinical application. A literature review pertaining to commercial medical systems which incorporate autonomous and semi-autonomous features, as well as experimental work involving automation of various surgical procedures, is presented. Results are drawn from major databases, excluding papers not experimentally implemented on real robots. Our search yielded several experimental and clinical applications, describing progress in autonomous surgical manoeuvres, ultrasound guidance, optical coherence tomography guidance, cochlear implantation, motion compensation, orthopaedic, neurological and radiosurgery robots. Autonomous and semi-autonomous systems are beginning to emerge in various interventions, automating important steps of the operation. These systems are expected to become standard modality and revolutionize the face of surgery. Copyright © 2011 John Wiley & Sons, Ltd.

  12. Therapeutic ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Crum, Lawrence A [Center for Industrial and Medical Ultrasound, 1013 NE 40th Street, University of Washington, Seattle, WA 98105 (United States)

    2004-01-01

    The use of ultrasound in medicine is now quite commonplace, especially with the recent introduction of small, portable and relatively inexpensive, hand-held diagnostic imaging devices. Moreover, ultrasound has expanded beyond the imaging realm, with methods and applications extending to novel therapeutic and surgical uses. These applications broadly include: tissue ablation, acoustocautery, lipoplasty, site-specific and ultrasound mediated drug activity, extracorporeal lithotripsy, and the enhancement of natural physiological functions such as wound healing and tissue regeneration. A particularly attractive aspect of this technology is that diagnostic and therapeutic systems can be combined to produce totally non-invasive, imageguided therapy. This general lecture will review a number of these exciting new applications of ultrasound and address some of the basic scientific questions and future challenges in developing these methods and technologies for general use in our society. We shall particularly emphasize the use of High Intensity Focused Ultrasound (HIFU) in the treatment of benign and malignant tumors as well as the introduction of acoustic hemostasis, especially in organs which are difficult to treat using conventional medical and surgical techniques. (amum lecture)

  13. Design and development of an ultrasound calibration phantom and system

    Science.gov (United States)

    Cheng, Alexis; Ackerman, Martin K.; Chirikjian, Gregory S.; Boctor, Emad M.

    2014-03-01

    Image-guided surgery systems are often used to provide surgeons with informational support. Due to several unique advantages such as ease of use, real-time image acquisition, and no ionizing radiation, ultrasound is a common medical imaging modality used in image-guided surgery systems. To perform advanced forms of guidance with ultrasound, such as virtual image overlays or automated robotic actuation, an ultrasound calibration process must be performed. This process recovers the rigid body transformation between a tracked marker attached to the ultrasound transducer and the ultrasound image. A phantom or model with known geometry is also required. In this work, we design and test an ultrasound calibration phantom and software. The two main considerations in this work are utilizing our knowledge of ultrasound physics to design the phantom and delivering an easy to use calibration process to the user. We explore the use of a three-dimensional printer to create the phantom in its entirety without need for user assembly. We have also developed software to automatically segment the three-dimensional printed rods from the ultrasound image by leveraging knowledge about the shape and scale of the phantom. In this work, we present preliminary results from using this phantom to perform ultrasound calibration. To test the efficacy of our method, we match the projection of the points segmented from the image to the known model and calculate a sum squared difference between each point for several combinations of motion generation and filtering methods. The best performing combination of motion and filtering techniques had an error of 1.56 mm and a standard deviation of 1.02 mm.

  14. Evaluation of Elastic Stiffness in Healing Achilles Tendon After Surgical Repair of a Tendon Rupture Using In Vivo Ultrasound Shear Wave Elastography.

    Science.gov (United States)

    Zhang, Li-ning; Wan, Wen-bo; Wang, Yue-xiang; Jiao, Zi-yu; Zhang, Li-hai; Luo, Yu-kun; Tang, Pei-fu

    2016-04-09

    BACKGROUND There has been no published report assessing the mechanical properties of a repaired Achilles tendon after surgery using shear wave elastography (SWE). The aim of this study was to investigate the changes in mechanical properties of the healing Achilles tendon after surgical repair of a tendon rupture using ultrasound SWE and how these changes correlate with tendon function. MATERIAL AND METHODS Twenty-six patients who underwent surgical repair for Achilles tendon rupture were examined with ultrasound SWE coupled with a linear array transducer (4-15 MHz). The elasticity values of the repaired Achilles tendon in a longitudinal view were measured at 12, 24, and 48 weeks postoperatively. Functional outcomes were assessed with the American Orthopedic Foot and Ankle Society (AOFAS) rating system at 12, 24, and 48 weeks postoperatively. General linear regression analysis and correlation coefficients were used to analyze the relationship between elasticity and the AOFAS score. RESULTS There were significant differences with respect to the mean elasticity values and functional scores of the repaired Achilles tendon at 12, 24, and 48 weeks postoperatively (all PTendon function was positively correlated with the elasticity of the repaired Achilles tendon (P=0.0003). CONCLUSIONS Our findings suggest that SWE can provide biomechanical information for evaluating the mechanical properties of healing Achilles tendon and predict Achilles tendon function.

  15. A motorized ultrasound system for MRI-ultrasound fusion guided prostatectomy

    Science.gov (United States)

    Seifabadi, Reza; Xu, Sheng; Pinto, Peter; Wood, Bradford J.

    2016-03-01

    Purpose: This study presents MoTRUS, a motorized transrectal ultrasound system, to enable remote navigation of a transrectal ultrasound (TRUS) probe during da Vinci assisted prostatectomy. MoTRUS not only provides a stable platform to the ultrasound probe, but also allows the physician to navigate it remotely while sitting on the da Vinci console. This study also presents phantom feasibility study with the goal being intraoperative MRI-US image fusion capability to bring preoperative MR images to the operating room for the best visualization of the gland, boundaries, nerves, etc. Method: A two degree-of-freedom probe holder is developed to insert and rotate a bi-plane transrectal ultrasound transducer. A custom joystick is made to enable remote navigation of MoTRUS. Safety features have been considered to avoid inadvertent risks (if any) to the patient. Custom design software has been developed to fuse pre-operative MR images to intraoperative ultrasound images acquired by MoTRUS. Results: Remote TRUS probe navigation was evaluated on a patient after taking required consents during prostatectomy using MoTRUS. It took 10 min to setup the system in OR. MoTRUS provided similar capability in addition to remote navigation and stable imaging. No complications were observed. Image fusion was evaluated on a commercial prostate phantom. Electromagnetic tracking was used for the fusion. Conclusions: Motorized navigation of the TRUS probe during prostatectomy is safe and feasible. Remote navigation provides physician with a more precise and easier control of the ultrasound image while removing the burden of manual manipulation of the probe. Image fusion improved visualization of the prostate and boundaries in a phantom study.

  16. Programmable Real-time Clinical Photoacoustic and Ultrasound Imaging System.

    Science.gov (United States)

    Kim, Jeesu; Park, Sara; Jung, Yuhan; Chang, Sunyeob; Park, Jinyong; Zhang, Yumiao; Lovell, Jonathan F; Kim, Chulhong

    2016-10-12

    Photoacoustic imaging has attracted interest for its capacity to capture functional spectral information with high spatial and temporal resolution in biological tissues. Several photoacoustic imaging systems have been commercialized recently, but they are variously limited by non-clinically relevant designs, immobility, single anatomical utility (e.g., breast only), or non-programmable interfaces. Here, we present a real-time clinical photoacoustic and ultrasound imaging system which consists of an FDA-approved clinical ultrasound system integrated with a portable laser. The system is completely programmable, has an intuitive user interface, and can be adapted for different applications by switching handheld imaging probes with various transducer types. The customizable photoacoustic and ultrasound imaging system is intended to meet the diverse needs of medical researchers performing both clinical and preclinical photoacoustic studies.

  17. High Intensity Focused Ultrasound Tumor Therapy System and Its Application

    Science.gov (United States)

    Sun, Fucheng; He, Ye; Li, Rui

    2007-05-01

    At the end of last century, a High Intensity Focused Ultrasound (HIFU) tumor therapy system was successfully developed and manufactured in China, which has been already applied to clinical therapy. This article aims to discuss the HIFU therapy system and its application. Detailed research includes the following: power amplifiers for high-power ultrasound, ultrasound transducers with large apertures, accurate 3-D mechanical drives, a software control system (both high-voltage control and low-voltage control), and the B-mode ultrasonic diagnostic equipment used for treatment monitoring. Research on the dosage of ultrasound required for tumour therapy in multiple human cases has made it possible to relate a dosage formula, presented in this paper, to other significant parameters such as the volume of thermal tumor solidification, the acoustic intensity (I), and the ultrasound emission time (tn). Moreover, the HIFU therapy system can be applied to the clinical treatment of both benign and malignant tumors in the pelvic and abdominal cavity, such as uterine fibroids, liver cancer and pancreatic carcinoma.

  18. An integrated ultrasound-guided high intensity focused ultrasound system for in-vivo experiment

    Science.gov (United States)

    Liu, Dalong; Ebbini, Emad S.

    2017-03-01

    We present the system architecture of an integrated Ultrasound-guided High Intensity Focused Ultrasound (USgHIFU) system for image-guided surgery and temperature tracking in vivo. The system is capable of operating with multiple frontends. Current implementation has a SonixRP for imaging and a custom designed dual mode ultrasound array (DMUA) system (32Tx/32Rx) for imaging/therapy. The highlights of the system include a fully-programmable, multiple data stream capable data processing engine, and an arbitrarily programmable high power array driver that is able to synthesize complex beam patterns in space and time. The data processing engine features a pipeline-style design that can be programmed on-the-fly by re-arranging the pre-verified GPU-accelerated high performance pipeline blocks, which cover an extensive range from basic functions such as filtering to specialized processing like speckle tracking. Furthermore, the pipeline design also has the option of bringing in MATLAB (Mathworks, Natick, MA, US) as part of the processing chain, thus vastly increase the capability of the system. By properly balancing the processing load between GPU-enabled routine and MATLAB script. This allows one to achieve a high degree of flexibility while meeting real-time constraints. Results are presented from in vivo rat experiment. Where low dose of therapeutic ultrasound was delivered into the hind limb of the Copenhagen rats using DMUA and temperature was tracked using a linear probe (HST, Ultrasonix). The data is processed in realtime with MATLAB in the loop to perform temperature regularization. Results show that we can reliably track the low temperature heating in the presence of motion artifacts (respiration and pulsation).

  19. Imaging of foreign bodies in the face and ultrasound guided surgical removal; Diagnostico por imagem de corpos estranhos da face e retirada cirurgica guiada por ultra-sonografia

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Claudio Marcio Amaral de Oliveira; Gambin, Moises; Ribeiro, Erica Barreiros; Amarante Junior, Jose Luiz de Medeiros [Hospital Naval Marcilio Dias, Rio de Janeiro, RJ (Brazil)]. E-mail: cmaol@br.inter.net; cmaolima@hotmail.com; Monteiro, Alexandra Maria Vieira [Pontificia Univ. Catolica do Rio de Janeiro (PUC/Rio), RJ (Brazil). Curso de Pos-Graduacao em Radiologia

    2006-10-15

    The identification and surgical removal of foreign bodies is a complex procedure in medical practice, principally when the involved material is radiolucent. The technological advent of the ultrasonography equipment comes enlarging the field of application of this method more and more, in medical practice. The authors describe a case of an ultrasound guided surgical removal of glass fragments from the face of a patient. The foreign bodies were previously diagnosed by ultrasound and computed tomography. The guided technic showed secure, less invasive and efficient, allowing the retreat of all the fragments. (author)

  20. An intraoperative 3D ultrasound system for tumor margin determination in breast cancer surgery.

    Science.gov (United States)

    DeJean, Paul; Brackstone, Muriel; Fenster, Aaron

    2010-02-01

    The purpose of this study was to analyze the clinical utility of a portable three-dimensional ultrasound (3DUS) system to be used for surgical guidance of lumpectomy surgeries. In 11%-60% of lumpectomy surgeries, a second surgery is required to fully resect the tumor. Previous studies have used 3DUS as a guidance tool with the hope of more accuracy in resecting the entire tumor during the first surgery. However, they utilized larger systems, which are not easily integrated into the operating room. The portable 3DUS scanning system we developed consisted of a motorized "tilt" scanner coupled to a Terason t3000 portable ultrasound machine (Terason Ultrasound, Burlington, MA). The 3DUS system was evaluated by measuring agar "tumor" phantoms of known volumes and acquiring and segmenting images from nine patients undergoing lumpectomy. Experiments on simulated agar tumor phantoms have shown that our device could be used to measure objects with smooth, well-defined boundaries of known volume with an error of 3%. It was possible to view and segment estimated tumor margins from the clinical images in three dimensions. Correspondence between measurements obtained in the laboratory and the operating room varied with tumor geometry and the degree of spiculation in the ultrasound image. The measured values obtained by the system did not correspond closely with those obtained using histology. However, a more accurate histological measurement using 3D histology may provide a better basis for comparison. The results of imaging simulated agar tumor phantoms indicate the system's consistency in measuring objects of known volume and geometry. The system could be used for segmenting the approximate boundary of lumpectomy patients' breast tumors relative to inserted guide wires. The potential advantages of this system are a reduction in the number of re-excision surgeries required and a reduction in the operative time with the patient under anesthesia.

  1. CISUS: an integrated 3D ultrasound system for IGT using a modular tracking API

    Science.gov (United States)

    Boctor, Emad M.; Viswanathan, Anand; Pieper, Steve; Choti, Michael A.; Taylor, Russell H.; Kikinis, Ron; Fichtinger, Gabor

    2004-05-01

    Ultrasound has become popular in clinical/surgical applications, both as the primary image guidance modality and also in conjunction with other modalities like CT or MRI. Three dimensional ultrasound (3DUS) systems have also demonstrated usefulness in image-guided therapy (IGT). At the same time, however, current lack of open-source and open-architecture multi-modal medical visualization systems prevents 3DUS from fulfilling its potential. Several stand-alone 3DUS systems, like Stradx or In-Vivo exist today. Although these systems have been found to be useful in real clinical setting, it is difficult to augment their functionality and integrate them in versatile IGT systems. To address these limitations, a robotic/freehand 3DUS open environment (CISUS) is being integrated into the 3D Slicer, an open-source research tool developed for medical image analysis and surgical planning. In addition, the system capitalizes on generic application programming interfaces (APIs) for tracking devices and robotic control. The resulting platform-independent open-source system may serve as a valuable tool to the image guided surgery community. Other researchers could straightforwardly integrate the generic CISUS system along with other functionalities (i.e. dual view visualization, registration, real-time tracking, segmentation, etc) to rapidly create their medical/surgical applications. Our current driving clinical application is robotically assisted and freehand 3DUS-guided liver ablation, which is fully being integrated under the CISUS-3D Slicer. Initial functionality and pre-clinical feasibility are demonstrated on phantom and ex-vivo animal models.

  2. [Clinical application of Da Vinci surgical system in China].

    Science.gov (United States)

    Jin, Zhenyu

    2014-01-01

    Da Vinci robotic surgical system leads the development of minimally invasive surgical techniques. By using Da Vinci surgical robot for minimally invasive surgery, it brings a lot of advantages to the surgeons. Since 2008, Da Vinci surgeries have been performed in 14 hospitals in domestic cities such as Beijing and Shanghai. Until the end of 2012, 3 551 cases of Da Vinci robotic surgery have been performed, covering various procedures of various surgical departments including the department of general surgery, urology, cardiovascular surgery, thoracic surgery, gynecology, and etc. Robotic surgical technique has made remarkable achievements.

  3. Development of a Mechanical Scanning-type Intravascular Ultrasound System Using a Miniature Ultrasound Motor

    Science.gov (United States)

    Tanabe, Masayuki; Xie, Shangping; Tagawa, Norio; Moriya, Tadashi; Furukawa, Yuji

    2007-07-01

    Intravascular ultrasound (IVUS) plays an important role for the detection of arteriosclerosis, which causes the ischemic heart disease. In mechanical scanning-type IVUS, it is necessary to rotate a transducer or a reflecting mirror. A method that involves rotating the transducer using a torque wire causes image distortion (NURD: non uniform rotation distortion). For a method that involves placing an electromagnetic motor on the tip of an IVUS probe is difficult to miniaturize the probe. Our objectives are to miniaturize the probe (1 mm in diameter, 5 mm in length) and to remove NURD. Therefore, we conducted a study to assess the feasibility of attaining these objectives by constructing a prototype IVUS system, in which an ultrasound motor using a stator in the form of a helical coil (abbreviated as CS-USM: coiled stator-ultrasonic motor) is incorporated, and to clarify problems that need to be solved in constructing the probe.

  4. A preliminary study on the effect of ultrasound therapy on the healing of surgically severed achilles tendons in five dogs.

    Science.gov (United States)

    Saini, N S; Roy, K S; Bansal, P S; Singh, B; Simran, P S

    2002-08-01

    This study was conducted on the left Achilles tendon in five clinically normal dogs. The Achilles tendon was surgically exposed and severed 3-4 cm proximal to the point of its insertion. Tenorrhaphy was undertaken by the application of three sutures on the various tendon units of the Achilles tendon using single locking-loop sutures with polyamide no. 1-0. The superficial digital flexor tendon was sutured with catgut using two horizontal mattress sutures. No ultrasound therapy was used in the animals of group I (control). Ultrasound therapy was given to the animals of group II (treated) starting from the third day post-operatively at 0.5 W/cm2 for 10 min daily for 10 days. A cortical screw was used for immobilization of the tibiotarsal joint which was removed 4 weeks after tenorrhaphy. Post-operatively, healing of the Achilles tendon was monitored using clinical observations, ultrasonography, gross and histomorphological observations at various intervals up to 120 days in both groups. Clinically, the dogs showed significant lameness for the first 4-5 days, which disappeared earlier in the ultrasound-treated (group II) animals than the controls (group I). Extension and flexion of the hock joint were found to be near normal at 6 weeks after the repair of the Achilles tendon. Ultrasonography showed anechoic to hypo-echoic echo-texture on days 3 and 7 after repair. By day 40, the echo-texture started to improve to hypo-echoic in group II, but in group I anechoic areas were still observed. However, the tendon showed near normal mottled hypo- to hyper-echoic texture in both groups by day 120. Gross observations suggested that the Achilles tendon in group II showed comparatively fewer adhesions than in group I animals. Histologically, in group II (treated), on day 40, the union was comparatively better without any inflammatory reaction. Bundle formation had begun in the ultrasound-treated animals which was not observed in the control animals. By day 90, more compact

  5. Point-of-Care Ultrasound and the Rapid Response System.

    Science.gov (United States)

    Lakoff, Daniel J; Barghash, Maya H; Lorin, Scott; Ungaro, Ryan; Nguyen, Vinh-Tung; Baumgardner, Jeffrey; Nelson, Bret P; Narula, Jagat

    2013-12-01

    Over the years, the use of ultrasound has moved solely from the domain of the radiologist to that of the intensivist and emergentologist for use in acute care settings. By virtue of its ease of use and rapid learning curve to proficiency, we are now seeing an increased desire by internists to learn the modality and apply it at the patient's bedside. The rapid response system represents a rational starting point for the introduction of point-of-care ultrasound to the inpatient ward setting. Copyright © 2013 World Heart Federation (Geneva). Published by Elsevier B.V. All rights reserved.

  6. Modeling of higher harmonics formation in medical ultrasound systems

    DEFF Research Database (Denmark)

    Taylor, Louise Kold; Schlaikjer, Malene; Jensen, Jørgen Arendt

    2002-01-01

    The pressure eld emitted from multi-element medical ultrasound transducers can be simulated with Field II in the linear regime. By expanding this program's application to the nonlinear regime, beamforming schemes can be studied under strong focusing and high pressure levels as well, providing...... a valuable tool for simulating ultrasound harmonic imaging. An extended version of Field II is obtained by means of operator splitting. The pressure eld is calculated by propagation of the eld from the transducer through a number of planes. Every plane serves as a virtual aperture for the next plane......, and nonlinear distortion is accounted for by the lossless Burgers' Equation. This method has no plane-wave approximation and the full eects of diraction, attenuation, and nonlinear wave propagation can be observed under electronic focusing of array transducers in medical ultrasound systems. A single example...

  7. Modeling of higher harmonics formation in medical ultrasound systems

    DEFF Research Database (Denmark)

    Taylor, Louise Kold; Schlaikjer, Malene; Jensen, Jørgen Arendt

    2002-01-01

    , and nonlinear distortion is accounted for by the lossless Burgers' Equation. This method has no plane-wave approximation and the full eects of diraction, attenuation, and nonlinear wave propagation can be observed under electronic focusing of array transducers in medical ultrasound systems. A single example...

  8. Ultrasound Vector Flow Imaging: Part II: Parallel Systems

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Nikolov, Svetoslav Ivanov; Yu, Alfred C. H.;

    2016-01-01

    ultrasound imaging for studying brain function in animals. The paper explains the underlying acquisition and estimation methods for fast 2-D and 3-D velocity imaging and gives a number of examples. Future challenges and the potentials of parallel acquisition systems for flow imaging are also discussed....

  9. Multispectral photoacoustic imaging of nerves with a clinical ultrasound system

    Science.gov (United States)

    Mari, Jean Martial; West, Simeon; Beard, Paul C.; Desjardins, Adrien E.

    2014-03-01

    Accurate and efficient identification of nerves is of great importance during many ultrasound-guided clinical procedures, including nerve blocks and prostate biopsies. It can be challenging to visualise nerves with conventional ultrasound imaging, however. One of the challenges is that nerves can have very similar appearances to nearby structures such as tendons. Several recent studies have highlighted the potential of near-infrared optical spectroscopy for differentiating nerves and adjacent tissues, as this modality can be sensitive to optical absorption of lipids that are present in intra- and extra-neural adipose tissue and in the myelin sheaths. These studies were limited to point measurements, however. In this pilot study, a custom photoacoustic system with a clinical ultrasound imaging probe was used to acquire multi-spectral photoacoustic images of nerves and tendons from swine ex vivo, across the wavelength range of 1100 to 1300 nm. Photoacoustic images were processed and overlaid in colour onto co-registered conventional ultrasound images that were acquired with the same imaging probe. A pronounced optical absorption peak centred at 1210 nm was observed in the photoacoustic signals obtained from nerves, and it was absent in those obtained from tendons. This absorption peak, which is consistent with the presence of lipids, provides a novel image contrast mechanism to significantly enhance the visualization of nerves. In particular, image contrast for nerves was up to 5.5 times greater with photoacoustic imaging (0.82 +/- 0.15) than with conventional ultrasound imaging (0.148 +/- 0.002), with a maximum contrast of 0.95 +/- 0.02 obtained in photoacoustic mode. This pilot study demonstrates the potential of photoacoustic imaging to improve clinical outcomes in ultrasound-guided interventions in regional anaesthesia and interventional oncology.

  10. Development and implementation of ultrasound picture archiving and communication system

    Science.gov (United States)

    Weinberg, Wolfram S.; Tessler, Franklin N.; Grant, Edward G.; Kangarloo, Hooshang; Huang, H. K.

    1990-08-01

    The Department of Radiological Sciences at the UCLA School of Medicine is developing an archiving and communication system (PACS) for digitized ultrasound images. In its final stage the system will involve the acquisition and archiving of ultrasound studies from four different locations including the Center for Health Sciences, the Department for Mental Health and the Outpatient Radiology and Endoscopy Departments with a total of 200-250 patient studies per week. The concept comprises two stages of image manipulation for each ultrasound work area. The first station is located close to the examination site and accomodates the acquisition of digital images from up to five ultrasound devices and provides for instantaneous display and primary viewing and image selection. Completed patient studies are transferred to a main workstation for secondary review, further analysis and comparison studies. The review station has an on-line storage capacity of 10,000 images with a resolution of 512x512 8 bit data to allow for immediate retrieval of active patient studies of up to two weeks. The main work stations are connected through the general network and use one central archive for long term storage and a film printer for hardcopy output. First phase development efforts concentrate on the implementation and testing of a system at one location consisting of a number of ultrasound units with video digitizer and network interfaces and a microcomputer workstation as host for the display station with two color monitors, each allowing simultaneous display of four 512x512 images. The discussion emphasizes functionality, performance and acceptance of the system in the clinical environment.

  11. High-resolution imaging with a real-time synthetic aperture ultrasound system: a phantom study

    Science.gov (United States)

    Huang, Lianjie; Labyed, Yassin; Simonetti, Francesco; Williamson, Michael; Rosenberg, Robert; Heintz, Philip; Sandoval, Daniel

    2011-03-01

    It is difficult for ultrasound to image small targets such as breast microcalcifications. Synthetic aperture ultrasound imaging has recently developed as a promising tool to improve the capabilities of medical ultrasound. We use two different tissueequivalent phantoms to study the imaging capabilities of a real-time synthetic aperture ultrasound system for imaging small targets. The InnerVision ultrasound system DAS009 is an investigational system for real-time synthetic aperture ultrasound imaging. We use the system to image the two phantoms, and compare the images with those obtained from clinical scanners Acuson Sequoia 512 and Siemens S2000. Our results show that synthetic aperture ultrasound imaging produces images with higher resolution and less image artifacts than Acuson Sequoia 512 and Siemens S2000. In addition, we study the effects of sound speed on synthetic aperture ultrasound imaging and demonstrate that an accurate sound speed is very important for imaging small targets.

  12. Development of a Cognitive Robotic System for Simple Surgical Tasks

    Directory of Open Access Journals (Sweden)

    Riccardo Muradore

    2015-04-01

    Full Text Available The introduction of robotic surgery within the operating rooms has significantly improved the quality of many surgical procedures. Recently, the research on medical robotic systems focused on increasing the level of autonomy in order to give them the possibility to carry out simple surgical actions autonomously. This paper reports on the development of technologies for introducing automation within the surgical workflow. The results have been obtained during the ongoing FP7 European funded project Intelligent Surgical Robotics (I-SUR. The main goal of the project is to demonstrate that autonomous robotic surgical systems can carry out simple surgical tasks effectively and without major intervention by surgeons. To fulfil this goal, we have developed innovative solutions (both in terms of technologies and algorithms for the following aspects: fabrication of soft organ models starting from CT images, surgical planning and execution of movement of robot arms in contact with a deformable environment, designing a surgical interface minimizing the cognitive load of the surgeon supervising the actions, intra-operative sensing and reasoning to detect normal transitions and unexpected events. All these technologies have been integrated using a component-based software architecture to control a novel robot designed to perform the surgical actions under study. In this work we provide an overview of our system and report on preliminary results of the automatic execution of needle insertion for the cryoablation of kidney tumours.

  13. Development of a Cognitive Robotic System for Simple Surgical Tasks

    Directory of Open Access Journals (Sweden)

    Riccardo Muradore

    2015-04-01

    Full Text Available The introduction of robotic surgery within the operating rooms has significantly improved the quality of many surgical procedures. Recently, the research on medical robotic systems focused on increasing the level of autonomy in order to give them the possibility to carry out simple surgical actions autonomously. This paper reports on the development of technologies for introducing automation within the surgical workflow. The results have been obtained during the ongoing FP7 European funded project Intelligent Surgical Robotics (I-SUR. The main goal of the project is to demonstrate that autonomous robotic surgical systems can carry out simple surgical tasks effectively and without major intervention by surgeons. To fulfil this goal, we have developed innovative solutions (both in terms of technologies and algorithms for the following aspects: fabrication of soft organ models starting from CT images, surgical planning and execution of movement of robot arms in contact with a deformable environment, designing a surgical interface minimizing the cognitive load of the surgeon supervising the actions, intra-operative sensing and reasoning to detect normal transitions and unexpected events. All these technologies have been integrated using a component-based software architecture to control a novel robot designed to perform the surgical actions under study. In this work we provide an overview of our system and report on preliminary results of the automatic execution of needle insertion for the cryoablation of kidney tumours.

  14. A-scan ultrasound system for real-time puncture safety assessment during percutaneous nephrolithotomy

    Science.gov (United States)

    Rodrigues, Pedro L.; Rodrigues, Nuno F.; Fonseca, Jaime C.; von Krüger, M. A.; Pereira, W. C. A.; Vilaça, João. L.

    2015-03-01

    Background: Kidney stone is a major universal health problem, affecting 10% of the population worldwide. Percutaneous nephrolithotomy is a first-line and established procedure for disintegration and removal of renal stones. Its surgical success depends on the precise needle puncture of renal calyces, which remains the most challenging task for surgeons. This work describes and tests a new ultrasound based system to alert the surgeon when undesirable anatomical structures are in between the puncture path defined through a tracked needle. Methods: Two circular ultrasound transducers were built with a single 3.3-MHz piezoelectric ceramic PZT SN8, 25.4 mm of radius and resin-epoxy matching and backing layers. One matching layer was designed with a concave curvature to work as an acoustic lens with long focusing. The A-scan signals were filtered and processed to automatically detect reflected echoes. Results: The transducers were mapped in water tank and tested in a study involving 45 phantoms. Each phantom mimics different needle insertion trajectories with a percutaneous path length between 80 and 150 mm. Results showed that the beam cross-sectional area oscillates around the ceramics radius and it was possible to automatically detect echo signals in phantoms with length higher than 80 mm. Conclusions: This new solution may alert the surgeon about anatomical tissues changes during needle insertion, which may decrease the need of X-Ray radiation exposure and ultrasound image evaluation during percutaneous puncture.

  15. First practical experiences with the optoacoustic/ultrasound system OPUS

    Science.gov (United States)

    Zell, Karin; Vogel, Mika W.; Menzenbach, Peter; Niessner, Reinhard; Haisch, Christoph

    2008-02-01

    The OPUS (OPtoacoustic UltraSound) system combines a conventional ultrasound (US) system with a specially designed OPO (Optical Parametrical Oscillator) laser system to generate and detect optoacoustical (OA) signals at multiple wavelengths. The intention of this combination was to demonstrate that a conventional ultrasound system can be transformed into an optoacoustic module without major modifications. To offer operational ease of use similar to those of the conventional US instrumentation, i.e. slow moving of the US transducer over the examined tissue area, a high repetition rate of the laser is required. A repetition rate of 100 Hz of the laser system enables a fast image frame rate. Different approaches for the presentation of the two types of images to the operator are compared. For an optimum applicability of the system we found it essential to provide both, the well-known US image and the OA image of the same tissue section to the user. The operator has now the possibility to overlay both images on one screen and thus to extract the desired information from each imaging mode.

  16. An Ultrasound Robotic System Using the Commercial Robot UR5

    Directory of Open Access Journals (Sweden)

    Kim eMathiassen

    2016-02-01

    Full Text Available The use of robots in health care has increased dramatically over the last decade. One area of research has been to use robots to conduct ultrasound examinations, either controlled by a physician or autonomously. This paper examines the possibility of using the commercial robot UR5 from Universal Robots to make a tele-operated robotic ultrasound system. Physicians diagnosing patients using ultrasound probes are prone to repetitive strain injuries, as they are required to hold the probe in uncomfortable positions and exert significant static force. The main application for the system is to relieve the physician of this strain by letting the them control a robot that holds the probe. A set of requirements for the system is derived from the state-of-the-art systems found in the research literature. The system is developed through a low-level interface for the robot, effectively building a new software framework for controlling it. Compliance force control and forward flow haptic control of the robot was implemented. Experiments are conducted to quantify the performance of the two control schemes. The force control is estimated to have a bandwidth of 16.6 Hz, while the haptic control is estimated to have a bandwidth of 65.4 Hz for the position control of the slave and 13.4 Hz for the force control of the master. Overall, the system meets the derived requirements and the main conclusion is that it is feasible to use the UR5 robot for robotic ultrasound applications.

  17. Ultrasound-guided surgical treatment for ulnar nerve entrapment: a cadaver study.

    Science.gov (United States)

    Poujade, T; Hanouz, N; Lecoq, B; Hulet, C; Collon, S

    2014-09-01

    Several open and endoscopic techniques for the surgical treatment of ulnar nerve entrapment at the elbow (cubital tunnel syndrome) have been described that provide decompression with or without anterior transposition. Based on our experience with US-guided decompression for carpal tunnel syndrome in our department, we developed a similar surgical technique for the decompression of the ulnar nerve at the elbow. Using sixteen cadaver upper limbs, we performed decompression of all the structures possibly responsible for ulnar nerve compression at the elbow. The structures involved were Struthers' arcade, the cubital tunnel retinaculum, Osborne's fascia and Amadio-Beckenbaugh's arcade. The procedure was followed by anatomical dissection to confirm complete sectioning of the compressive structures, absence of iatrogenic vascular or nervous injuries and absence of nerve dislocation or instability. There were no remaining compressive structures after the release procedure. There was no iatrogenic damage to the nerves and no nerve dislocation was observed during elbow flexion or extension. In 3.4% cases, a thin superficial layer of one or more of the identified structures remained but these did not appear to compress the nerve based on US imaging. Using ultrasonographic visualization of the nerve and compressive structures is easy. Each procedure can be tailored according to the nerve compression sites. Our cadaveric study shows the feasibility of an US-guided percutaneous surgical release for ulnar nerve entrapment.

  18. Dissimilar trend of nonlinearity in ultrasound transducers and systems at resonance and non-resonance frequencies

    DEFF Research Database (Denmark)

    Ghasemi, Negareh; Zare, Firuz; Davari, Pooya

    2017-01-01

    Several factors can affect performance of an ultrasound system such as quality of excitation signal and ultrasound transducer behaviour. Nonlinearity of piezoelectric ultrasound transducers is a key determinant in designing a proper driving power supply. Although, the nonlinearity of piezoelectri...... receiver is a function of a voltage across the resistor in the RLC branches and is related to the resonance frequencies of the ultrasound transducer....

  19. Ultrasound guided percutaneous cholecystostomy in high-risk patients for surgical intervention

    Institute of Scientific and Technical Information of China (English)

    Huseyin Bakkaloglu; Hakan Yanar; Recep Guloglu; Korhan Taviloglu; Fatih Tunca; Murat Aksoy; Cemalettin Ertekin; Arzu Poyanli

    2006-01-01

    AIM: To assess the efficacy and safety of ultrasound guided percutaneous cholecystostomy (PC) in the treatment of acute cholecystitis in a well-defined high risk patients under general anesthesia.METHODS: The data of 27 consecutive patients who underwent percutaneous transhepatic cholecystostomy for the management of acute cholecystitis from January 1999 to June 2003 was retrospectively evaluated. All of the patients had both clinical and sonographic signs of acute cholecystitis and had comorbid diseases.RESULTS: Ultrasound revealed gallbladder stones in 25 patients and acalculous cholecystitis in two patients.Cholecystostomy catheters were removed 14-32 d (mean 23 d) after the procedure in cases where complete regression of all symptoms was achieved. There were statistically significant reductions in leukocytosis, (13.7× 103± 1.3× 103μg/L vs 13× 103± 1× 103μg/L,P<0.05 for 24 h after PC; 13.7 × 103 ± 1.3 × 103 μg/L vs8.3 × 103 ± 1.2 × 103 μg/L, P < 0.0001 for 72 h after PC), C -reactive protein (51.2 ± 18.5 mg/L vs 27.3 ±10.4 mg/L, P < 0.05 for 24 h after PC; 51.2 ± 18.5 mg/Lvs 5.4 ± 1.5 mg/L, P < 0.0001 for 72 h after PC), and fever (38 ± 0.35℃ vs 37.3 ± 0.32℃, P < 0.05 for 24h after PC; 38 ± 0.35℃ vs 36.9 ± 0.15℃, P < 0.0001 for 72 h after PC). Sphincterotomy and stone extraction was performed successfully with endoscopic retrograde cholangio-pancreatography (ERCP) in three patients.After cholecystostomy, 5 (18%) patients underwent delayed cholecystectomy without any complications.Three out of 22 patients were admitted with recurrent acute cholecystitis during the follow-up and recovered with medical treatment. Catheter dislodgement occurred in three patients spontaneously, and two of them were managed by reinsertion of the catheter.CONCLUSION: As an alternative to surgery, percutaneous cholecystostomy seems to be a safe method in critically ill patients with acute cholecystitis and can be performed with low mortality

  20. A dual-modality photoacoustic and ultrasound imaging system for noninvasive sentinel lymph node detection: preliminary clinical results

    Science.gov (United States)

    Erpelding, Todd N.; Garcia-Uribe, Alejandro; Krumholz, Arie; Ke, Haixin; Maslov, Konstantin; Appleton, Catherine; Margenthaler, Julie; Wang, Lihong V.

    2014-03-01

    Sentinel lymph node biopsy (SLNB) has emerged as an accurate, less invasive alternative to axillary lymph node dissection, and it has rapidly become the standard of care for patients with clinically node-negative breast cancer. The sentinel lymph node (SLN) hypothesis states that the pathological status of the axilla can be accurately predicted by determining the status of the first (i.e., sentinel) lymph nodes that drain from the primary tumor. Physicians use radio-labeled sulfur colloid and/or methylene blue dye to identify the SLN, which is most likely to contain metastatic cancer cells. However, the surgical procedure causes morbidity and associated expenses. To overcome these limitations, we developed a dual-modality photoacoustic and ultrasound imaging system to noninvasively detect SLNs based on the accumulation of methylene blue dye. Ultimately, we aim to guide percutaneous needle biopsies and provide a minimally invasive method for axillary staging of breast cancer. The system consists of a tunable dye laser pumped by a Nd:YAG laser, a commercial ultrasound imaging system (Philips iU22), and a multichannel data acquisition system which displays co-registered photoacoustic and ultrasound images in real-time. Our clinical results demonstrate that real-time photoacoustic imaging can provide sensitive and specific detection of methylene blue dye in vivo. While preliminary studies have shown that in vivo detection of SLNs by using co-registered photoacoustic and ultrasound imaging is feasible, further investigation is needed to demonstrate robust SLN detection.

  1. Experimental ultrasound system for real-time synthetic imaging

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Holm, Ole; Jensen, Lars Joost

    1999-01-01

    Digital signal processing is being employed more and more in modern ultrasound scanners. This has made it possible to do dynamic receive focusing for each sample and implement other advanced imaging methods. The processing, however, has to be very fast and cost-effective at the same time. Dedicated...... chips are used in order to do real time processing. This often makes it difficult to implement radically different imaging strategies on one platform and makes the scanners less accessible for research purposes. Here flexibility is the prime concern, and the storage of data from all transducer elements......-element ultrasound transducers, and to enable real-time or near realtime processing of the acquired data. The system will be capable of performing the processing for the currently available imaging methods, and will make it possible to perform initial trials in a clinical environment with new imaging modalities...

  2. Ultrasound of the peripheral nerves in systemic vasculitic neuropathies.

    Science.gov (United States)

    Grimm, Alexander; Décard, Bernhard F; Bischof, Antje; Axer, Hubertus

    2014-12-15

    Ultrasound of the peripheral nerves (PNUS) can be used to visualize nerve pathologies in polyneuropathies (PNP). The aim of this study was to investigate, whether PNUS provides additional information in patients with proven systemic vasculitic neuropathies (VN). Systematic ultrasound measurements of several peripheral nerves, the vagal nerve and the 6th cervical nerve root were performed in 14 patients and 22 healthy controls. Nerve conduction studies of the corresponding nerves were undertaken. Finally, the measured results were compared to a study population of demyelinating immune-mediated and axonal neuropathies. Patients with VN displayed significant smaller amplitudes of compound muscle action potentials (CMAP) (pneuropathies than in other axonal neuropathies, but significantly rarer than in demyelinating neuropathies. Focal CSA enlargement in one or more nerves in electrophysiologically axonal neuropathies can be a hint for VN and thus facilitate diagnostic and therapeutic procedures. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Towards 3D ultrasound image based soft tissue tracking: a transrectal ultrasound prostate image alignment system

    CERN Document Server

    Baumann, Michael; Daanen, Vincent; Troccaz, Jocelyne

    2007-01-01

    The emergence of real-time 3D ultrasound (US) makes it possible to consider image-based tracking of subcutaneous soft tissue targets for computer guided diagnosis and therapy. We propose a 3D transrectal US based tracking system for precise prostate biopsy sample localisation. The aim is to improve sample distribution, to enable targeting of unsampled regions for repeated biopsies, and to make post-interventional quality controls possible. Since the patient is not immobilized, since the prostate is mobile and due to the fact that probe movements are only constrained by the rectum during biopsy acquisition, the tracking system must be able to estimate rigid transformations that are beyond the capture range of common image similarity measures. We propose a fast and robust multi-resolution attribute-vector registration approach that combines global and local optimization methods to solve this problem. Global optimization is performed on a probe movement model that reduces the dimensionality of the search space a...

  4. Thermoradiotherapy using ultrasound hyperthermia system for supraclavicular lymph node metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Kuroki, Masaomi; Ono, Seiji; Shiba, Toru; Nishii, Ryuiti; Tamura, Shozo [Miyazaki Medical Coll., Kiyotake (Japan); Hirose, Tetsuo; Kawamura, Shinji

    1998-06-01

    Metastatic lymphnodes located in the subclavian region were treated with thermoradiotherapy using an ultrasound hyperthermia system. The mean size of tumor was 37 mm diameters (range 30-55 mm). Two cases were histologically diagnosed adenocarcinoma and one case was squamous cell carcinoma. The radiation dose was 40-64 Gy. The hyperthermia was performed once or twice a week, total number of session was 4-6. The ultrasound frequency of applicator was 1.0 MHz or 1.5 MHz. The temperature of tumor center was measured by thermo-couples. In three out of 4 cases the tumor temperature raised over 42.5degC within about 6 minutes but temperature of skin surface were under 37.0degC. Three cases had complete response and one case had partial response. Side effects were occurred in two cases, those were pain of clavicle and weakness of affected side arm and blister. The thermoradiotherapy using ultrasound hyperthermia system was considered to be useful modality for subclavian lymphnode metastasis. (author)

  5. Sonographic physical diagnosis 101: teaching senior medical students basic ultrasound scanning skills using a compact ultrasound system.

    Science.gov (United States)

    Angtuaco, Teresita L; Hopkins, Robert H; DuBose, Terry J; Bursac, Zoran; Angtuaco, Michael J; Ferris, Ernest J

    2007-06-01

    This project was designed to test the feasibility of introducing ultrasound to senior medical students as a primary diagnostic tool in the evaluation of patients. Specifically, its aim was to determine if it is possible for medical students untrained in sonography to gain basic competence in performing abdominal ultrasound with limited didactic and hands-on instructions. Registered sonographers provided the students with hands-on instructions on the use of a compact ultrasound system. They were likewise shown how to evaluate specific organs and perform measurements. The results of the student measurements and those obtained by the sonographers were compared. There was close correlation between the results obtained by sonographers and students on both normal and abnormal findings. This supports the concept that medical students can be taught basic ultrasound skills with limited didactic and hands-on instructions with the potential of using these skills in the patient clinics as an adjunct to routine physical diagnosis.

  6. A projective surgical navigation system for cancer resection

    Science.gov (United States)

    Gan, Qi; Shao, Pengfei; Wang, Dong; Ye, Jian; Zhang, Zeshu; Wang, Xinrui; Xu, Ronald

    2016-03-01

    Near infrared (NIR) fluorescence imaging technique can provide precise and real-time information about tumor location during a cancer resection surgery. However, many intraoperative fluorescence imaging systems are based on wearable devices or stand-alone displays, leading to distraction of the surgeons and suboptimal outcome. To overcome these limitations, we design a projective fluorescence imaging system for surgical navigation. The system consists of a LED excitation light source, a monochromatic CCD camera, a host computer, a mini projector and a CMOS camera. A software program is written by C++ to call OpenCV functions for calibrating and correcting fluorescence images captured by the CCD camera upon excitation illumination of the LED source. The images are projected back to the surgical field by the mini projector. Imaging performance of this projective navigation system is characterized in a tumor simulating phantom. Image-guided surgical resection is demonstrated in an ex-vivo chicken tissue model. In all the experiments, the projected images by the projector match well with the locations of fluorescence emission. Our experimental results indicate that the proposed projective navigation system can be a powerful tool for pre-operative surgical planning, intraoperative surgical guidance, and postoperative assessment of surgical outcome. We have integrated the optoelectronic elements into a compact and miniaturized system in preparation for further clinical validation.

  7. Potential and problems in ultrasound-responsive drug delivery systems

    Directory of Open Access Journals (Sweden)

    Zhao YZ

    2013-04-01

    Full Text Available Ying-Zheng Zhao,1,3 Li-Na Du,2 Cui-Tao Lu,1 Yi-Guang Jin,2 Shu-Ping Ge3 1Wenzhou Medical College, Wenzhou City, Zhejiang Province, 2Department of Pharmaceutical Sciences, Beijing Institute of Radiation Medicine, Beijing, People’s Republic of China; 3St Christopher’s Hospital for Children/Drexel University College of Medicine, Philadelphia, PA, USA Abstract: Ultrasound is an important local stimulus for triggering drug release at the target tissue. Ultrasound-responsive drug delivery systems (URDDS have become an important research focus in targeted therapy. URDDS include many different formulations, such as microbubbles, nanobubbles, nanodroplets, liposomes, emulsions, and micelles. Drugs that can be loaded into URDDS include small molecules, biomacromolecules, and inorganic substances. Fields of clinical application include anticancer therapy, treatment of ischemic myocardium, induction of an immune response, cartilage tissue engineering, transdermal drug delivery, treatment of Huntington’s disease, thrombolysis, and disruption of the blood–brain barrier. This review focuses on recent advances in URDDS, and discusses their formulations, clinical application, and problems, as well as a perspective on their potential use in the future. Keywords: ultrasound, targeted therapy, clinical application

  8. Independent Navigation System for a Surgical Colonoscope

    Directory of Open Access Journals (Sweden)

    Lilia A. Ochoa-Luna

    2013-08-01

    Full Text Available This paper provides a novel algorithm to attain the independent navigation of a colonoscopy surgical endoscope. First, it introduces a brief description of this issue through the scientist advance for medical robotics. It then makes a quickly count of the existent methods and at the end it provides the basis in order to propose a new alternative solution with help from vision-guidance. That means that images will be processed and interpreted with the purpose of maintaining the endoscope always at the intestine center. All this considered will help us to reduce colonoscopy surgeries consequences and the most important advantage of this new method proposed is that surgeons will accomplish their work easier and more efficiently.

  9. Mixed reality ultrasound guidance system: a case study in system development and a cautionary tale.

    Science.gov (United States)

    Ameri, Golafsoun; Baxter, John S H; Bainbridge, Daniel; Peters, Terry M; Chen, Elvis C S

    2017-08-31

    Real-time ultrasound has become a crucial aspect of several image-guided interventions. One of the main constraints of such an approach is the difficulty in interpretability of the limited field of view of the image, a problem that has recently been addressed using mixed reality, such as augmented reality and augmented virtuality. The growing popularity and maturity of mixed reality has led to a series of informal guidelines to direct development of new systems and to facilitate regulatory approval. However, the goals of mixed reality image guidance systems and the guidelines for their development have not been thoroughly discussed. The purpose of this paper is to identify and critically examine development guidelines in the context of a mixed reality ultrasound guidance system through a case study. A mixed reality ultrasound guidance system tailored to central line insertions was developed in close collaboration with an expert user. This system outperformed ultrasound-only guidance in a novice user study and has obtained clearance for clinical use in humans. A phantom study with 25 experienced physicians was carried out to compare the performance of the mixed reality ultrasound system against conventional ultrasound-only guidance. Despite the previous promising results, there was no statistically significant difference between the two systems. Guidelines for developing mixed reality image guidance systems cannot be applied indiscriminately. Each design decision, no matter how well justified, should be the subject of scientific and technical investigation. Iterative and small-scale evaluation can readily unearth issues and previously unknown or implicit system requirements. We recommend a wary eye in development of mixed reality ultrasound image guidance systems emphasizing small-scale iterative evaluation alongside system development. Ultimately, we recommend that the image-guided intervention community furthers and deepens this discussion into best practices in

  10. Ultrasonic transducer chip assembly, ultrasound probe, ultrasonic imaging system and ultrasound assembly and probe manufacturing methods

    NARCIS (Netherlands)

    Weekamp, J.W.; Henneken, V.A.; Groenland, A.W.; Louwerse, M.C.

    2015-01-01

    Disclosed is an ultrasonic transducer assembly comprising an ultrasonic transducer chip (100) having a main surface comprising a plurality of ultrasound transducer elements (112) and a plurality of first contacts (120) for connecting to said ultrasound transducer elements; a contact chip (400) havin

  11. Global Surgical Ecosystems: A Need for Systems Strengthening.

    Science.gov (United States)

    deVries, Catherine R; Rosenberg, Jenna S

    As surgery is gaining recognition as a critical component of universal health care worldwide, surgical communities have come together with unprecedented unity to advocate for systems to support surgical care. This community has long believed that much care could be performed in a cost-effective manner even in low resource settings, despite skepticism voiced by many in public health. To do so will require the development of new systems and re-vamping of old systems that are not effective. In the last five years, coalitions, expert panels, commissions, consortia and alliances have emerged to address these issues and there has been landmark success in advocacy with a new resolution at the 2015 World Health Assembly to include surgical care as a component of universal health coverage. It is critical to understand the ecosystem that constitutes the surgical environment. A surgical ecosystem could be described as a network of people, processes, and materials necessary for surgical services in the context of the facilities and environment in which it functions. We describe components of a functioning surgical ecosystem in terms of administration, support staff and clinicians, and the necessary sub-systems for providing consumable materials such as anesthetic medication and suture and sterile instruments. Related systems that must be integrated are facilities and utilities such as electricity, lighting, plumbing and waste management and even laundry. But especially in low and middle income countries (LMICs) lack of any one of these may be rate-limiting. The World Health Organization (WHO) has developed situational analyses and checklists for first level district hospitals to identify missing elements. A siloed approach cannot solve a systems problem. However, to scale up rapidly and to develop and sustain quality standards, a holistic "ecosystem" approach, including local and global professional societies and advocacy organizations will need to become engaged. Copyright

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... in x-rays ), thus there is no radiation exposure to the patient. Because ultrasound images are captured ... system disorders in both sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and fluid aspiration. Pelvic ultrasound can help to identify and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known ...

  14. Development of a Hybrid Magnetic Resonance and Ultrasound Imaging System

    Directory of Open Access Journals (Sweden)

    Victoria Sherwood

    2014-01-01

    Full Text Available A system which allows magnetic resonance (MR and ultrasound (US image data to be acquired simultaneously has been developed. B-mode and Doppler US were performed inside the bore of a clinical 1.5 T MRI scanner using a clinical 1–4 MHz US transducer with an 8-metre cable. Susceptibility artefacts and RF noise were introduced into MR images by the US imaging system. RF noise was minimised by using aluminium foil to shield the transducer. A study of MR and B-mode US image signal-to-noise ratio (SNR as a function of transducer-phantom separation was performed using a gel phantom. This revealed that a 4 cm separation between the phantom surface and the transducer was sufficient to minimise the effect of the susceptibility artefact in MR images. MR-US imaging was demonstrated in vivo with the aid of a 2 mm VeroWhite 3D-printed spherical target placed over the thigh muscle of a rat. The target allowed single-point registration of MR and US images in the axial plane to be performed. The system was subsequently demonstrated as a tool for the targeting and visualisation of high intensity focused ultrasound exposure in the rat thigh muscle.

  15. Prototype of a rectal wall ultrasound image analysis system

    Science.gov (United States)

    Xiao, Di; Ng, Wan S.; Abeyratne, Udantha R.; Tsang, Charles B.

    2002-05-01

    This paper presents a software system prototype for rectal wall ultrasound image processing, image display and 3D reconstruction and visualization of the rectal wall structure, which is aimed to help surgeons cope with large quantities of rectal wall ultrasound images. On the core image processing algorithm part, a novel multigradient field active contour model proposed by authors is used to complete the multi-layer boundary detection of the rectal wall. A novel unifying active contour model, which combines region information, gradient information and contour's internal constraint, is developed for tumor boundary detection. The region statistical information is described accurately by Gaussian Mixture Model, whose parameter solution is computed by Expectation-Maximization algorithm. The whole system is set up on Java platform. Java JAI technology is used for 2D image display, Java3D technology is employed for 3D reconstruction and visualization. The system prototype is currently composed of three main modules: image processing, image display and 3D visualization.

  16. Methods and systems for producing compounded ultrasound images

    DEFF Research Database (Denmark)

    2012-01-01

    Disclosed is a method for producing compounded ultrasound images by beamforming a first and a second low-resolution image using data from a first ultrasound emission, beamforming a third and a fourth low-resolution image using data from a second ultrasound emission, summing said first and said...

  17. Ultrasound pregnancy

    Science.gov (United States)

    Pregnancy sonogram; Obstetric ultrasonography; Obstetric sonogram; Ultrasound - pregnancy; IUGR - ultrasound; Intrauterine growth - ultrasound; Polyhydramnios - ultrasound; Oligohydramnios - ultrasound; ...

  18. A novel fusion imaging system for endoscopic ultrasound

    DEFF Research Database (Denmark)

    Gruionu, Lucian Gheorghe; Saftoiu, Adrian; Gruionu, Gabriel

    2016-01-01

    BACKGROUND AND OBJECTIVE: Navigation of a flexible endoscopic ultrasound (EUS) probe inside the gastrointestinal (GI) tract is problematic due to the small window size and complex anatomy. The goal of the present study was to test the feasibility of a novel fusion imaging (FI) system which uses...... electromagnetic (EM) sensors to co-register the live EUS images with the pre-procedure computed tomography (CT) data with a novel navigation algorithm and catheter. METHODS: An experienced gastroenterologist and a novice EUS operator tested the FI system on a GI tract bench top model. Also, the experienced...... time was 24.6 ± 6.6 min, while the time to reach the clinical target was 8.7 ± 4.2 min. CONCLUSIONS: The FI system is feasible for clinical use, and can reduce the learning curve for EUS procedures and improve navigation and targeting in difficult anatomic locations....

  19. Ultrasound transducer modeling--general theory and applications to ultrasound reciprocal systems.

    Science.gov (United States)

    Willatzen, M

    2001-01-01

    A tutorial presentation on the theory of reciprocal ultrasound systems is given, and a complete set of modeling equations for one-dimensional multi-layer ultrasound transducers is derived from first principles. The model includes dielectric losses and mechanical losses in the transducer material layers as well as sound absorption in the transmission medium. First, the so-called constitutive relations of a piezoelectric body are derived based on general thermodynamic considerations, assuming that transducer operation takes place under almost isentropic conditions. Second, full attention is given to transducers oscillating in the thickness mode, discarding all other vibration modes. Dynamic transducer equations are determined using Newton's Second Law, Poisson's equation, and the definition of strain applied to a piezoelectric transducer with one or more non-piezoelectric layers on the front surface (multilayer transducer). Boundary conditions include continuity of normal velocity and stress across material interfaces as well as a subsidiary electrical condition over the piezoceramic electrodes. Sound transmission is assumed to take place in a water bath such that the Rayleigh equation can be used to obtain the incoming pressure at the receiver aperture from the acceleration of the opposing transmitter. This allows, e.g., a detailed treatment of receiver signal variations as the receiver moves from the near-field zone to the far-field zone of the transmitter. In the remaining part of the paper, receiver voltage and current signals are obtained by solving the full set of dynamic equations numerically. Special attention is given to transducers consisting of a) a pure piezoceramic layer only, b) a piezoceramic layer and a quarter-wavelength matching layer of polyphenylensulphide (PPS), c) a piezoceramic layer and a half-wavelength matching layer of stainless steel, and d) a piezoceramic layer and a half-wavelength matching layer of stainless steel tuned to resonance by

  20. Optimizing the closed suction surgical drainage system.

    Science.gov (United States)

    Carruthers, Katherine H; Eisemann, Bradley S; Lamp, Susan; Kocak, Ergun

    2013-01-01

    Closed suction drains are indicated in a wide array of postoperative settings, with many distinct drainage systems available to the surgeon. The purpose of this study was to compare the suction gradients achieved using 2 different sizes of suction reservoirs and 2 different techniques for generating negative pressure. Drainage reservoirs of 100 and 400 ml were chosen to evaluate their ability to achieve suction. Suction was established in both sizes of drains by pressing the sides of the reservoir together or by pushing the bottom of the reservoir toward the top. Negative pressures were recorded with the reservoir empty, and after every 10-ml addition of saline. Averages were graphed to illustrate the applied suction over a range of drain volumes. The 100-ml drainage system reached a peak suction of -117.6 mmHg, while the 400-ml drainage system reached only a peak suction of -71.4 mmHg. Both of the maximum suction readings were achieved using the full-squeeze technique. The bottom-pushed-in technique did not result in any sustained measurable levels of suction using either of the reservoir volumes. Smaller drain reservoirs are more successful in generating a high initial suction than larger reservoirs, especially when the volume of fluid in the drain is relatively low. In all sizes of drains, compressing the sides of the reservoir is a far better technique for establishing negative pressure than pressing the bottom of the drain up toward the top.

  1. A Dual-Modality System for Both Multi-Color Ultrasound-Switchable Fluorescence and Ultrasound Imaging

    Science.gov (United States)

    Kandukuri, Jayanth; Yu, Shuai; Cheng, Bingbing; Bandi, Venugopal; D’Souza, Francis; Nguyen, Kytai T.; Hong, Yi; Yuan, Baohong

    2017-01-01

    Simultaneous imaging of multiple targets (SIMT) in opaque biological tissues is an important goal for molecular imaging in the future. Multi-color fluorescence imaging in deep tissues is a promising technology to reach this goal. In this work, we developed a dual-modality imaging system by combining our recently developed ultrasound-switchable fluorescence (USF) imaging technology with the conventional ultrasound (US) B-mode imaging. This dual-modality system can simultaneously image tissue acoustic structure information and multi-color fluorophores in centimeter-deep tissue with comparable spatial resolutions. To conduct USF imaging on the same plane (i.e., x-z plane) as US imaging, we adopted two 90°-crossed ultrasound transducers with an overlapped focal region, while the US transducer (the third one) was positioned at the center of these two USF transducers. Thus, the axial resolution of USF is close to the lateral resolution, which allows a point-by-point USF scanning on the same plane as the US imaging. Both multi-color USF and ultrasound imaging of a tissue phantom were demonstrated. PMID:28165390

  2. Comparative clinical study of ultrasound-guided A1 pulley release vs open surgical intervention in the treatment of trigger finger

    Science.gov (United States)

    Nikolaou, Vasileios S; Malahias, Michael-Alexander; Kaseta, Maria-Kyriaki; Sourlas, Ioannis; Babis, George C

    2017-01-01

    AIM To investigate the effectiveness of ultrasound-guided release of the first annular pulley and compare results with the conventional open operative technique. METHODS In this prospective randomized, single-center, clinical study, 32 patients with trigger finger or trigger thumb, grade II-IV according to Green classification system, were recruited. Two groups were formed; Group A (16 patients) was treated with an ultrasound-guided percutaneous release of the affected A1 pulley under local anesthesia. Group B (16 patients) underwent an open surgical release of the A1 pulley, through a 10-15 mm incision. Patients were assessed pre- and postoperatively (follow-up: 2, 4 and 12 wk) by physicians blinded to the procedures. Treatment of triggering (primary variable of interest) was expressed as the “success rate” per digit. The time for taking postoperative pain killers, range of motion recovery, QuickDASH test scores (Greek version), return to normal activities (including work), complications and cosmetic results were assessed. RESULTS The success rate in group A was 93.75% (15/16) and in group B 100% (16/16). Mean times in group A patients were 3.5 d for taking pain killers, 4.1 d for returning to normal activities, and 7.2 and 3.9 d for complete extension and flexion recovery, respectively. Mean QuickDASH scores in group A were 45.5 preoperatively and, 7.5, 0.5 and 0 after 2, 4, and 12 wk postoperatively. Mean times in group B patients were 2.9 d for taking pain killers, 17.8 d for returning to normal activities, and 5.6 and 3 d for complete extension and flexion recovery. Mean QuickDASH scores in group B were 43.2 preoperatively and, 8.2, 1.3 and 0 after 2, 4, and 12 wk postoperatively. The cosmetic results found excellent or good in 87.5% (14/16) of group A patients, while in 56.25% (9/16) of group B patients were evaluated as fair or poor. CONCLUSION Treatment of the trigger finger using ultrasonography resulted in fewer absence of work days, and better

  3. Estimation of tumor size in breast cancer comparing clinical examination, mammography, ultrasound and MRI-correlation with the pathological analysis of the surgical specimen.

    Science.gov (United States)

    Cortadellas, Tomas; Argacha, Paula; Acosta, Juan; Rabasa, Jordi; Peiró, Ricardo; Gomez, Margarita; Rodellar, Laura; Gomez, Sandra; Navarro-Golobart, Alejandra; Sanchez-Mendez, Sonia; Martinez-Medina, Milagros; Botey, Mireia; Muñoz-Ramos, Carlos; Xiberta, Manel

    2017-08-01

    To evaluate the best method in our center to measure preoperative tumor size in breast tumors, using as reference the tumor size in the postoperative surgical specimen. We compared physical examination vs. mammography vs. resonance vs. ultrasound. There are different studies in the literature with disparate results. This is a retrospective study. All the included patients have been studied by clinical examination performed by gynecologist or surgeon specialists in senology, and radiological tests (mammography, ultrasound and magnetic resonance imaging). The correlation of mammary examination, ultrasound, mammography and resonance with pathological anatomy was studied using the Pearson index. Subsequently, the results of such imaging tests were compared with the tumor size of the infiltrating component measured by anatomopathological study using a student's t test for related variables. The level of significance was set at 95%. Statistical package R. was used. A total of 73 cases were collected from October 2015 to July 2016 with diagnosis of infiltrating breast carcinoma. Twelve cases of carcinoma in situ and seven cases of neoadjuvant carcinoma are excluded. Finally, a total of 56 cases were included in the analysis. The mean age of the patients is 57 years. The histology is of infiltrating ductal carcinoma in 46 patients (80.7%), lobular in 8 (14%) and other carcinomas in 3 cases (5.2%). We verified the relationship between preoperative tumor size by physical examination, mammography, ultrasound (US) and magnetic resonance imaging (MRI), and the final size of the surgical specimen by applying a Pearson correlation test. A strong correlation was found between the physical examination results 0.62 (0.43-0.76 at 95% CI), ultrasound 0.68 (0.51-0.8 at 95% CI), mammography 0.57 (0.36-0.72 at 95% CI) and RM 0.51 (0.29-0.68 at 95% CI) with respect to pathological anatomy. The mean tumor size of the surgical specimen was 16.1 mm. Mean of tumor size by physical examination

  4. IMPORTANCE OF SOUTHAMPTON WOUND GRADING SYSTEM IN SURGICAL SITE INFECTION

    Directory of Open Access Journals (Sweden)

    Shaleen

    2014-05-01

    Full Text Available : Post-operative wound infection is defined as surgical site infection from 0-30 days after surgery, or infection to surgical site till one year in cases of implants like mesh, vascular grafts and prosthesis. This study was done to find out incidence of post-operative wound infection in surgical patients in rural setup. This study of post-operative wound infection was carried out from August 2008 to August 2010. The study is of 3275 patients who underwent surgery in the A.V.B.R.H. Significant association was observed between the nature of surgery and Southampton Wound Grading System. It concluded that severity rate of post-operative wound infection was increased from grade I to grade V which was found to be similar in clean to contaminated nature of surgery and that was found to be statistically significant at P value less than 0.001.

  5. Development of a Cognitive Robotic System for Simple Surgical Tasks

    OpenAIRE

    Riccardo Muradore; Paolo Fiorini; Gokhan Akgun; Duygun Erol Barkana; Marcello Bonfe; Fabrizio Boriero; Andrea Caprara; Giacomo Rossi; Riccardo Dodi; Ole Jakob Elle; Federica Ferraguti; Lorenza Gasperotti; Roger Gassert; Kim Mathiassen; Dilla Handini

    2015-01-01

    ARTICLE International Journal of Advanced Robotic Systems Development of a Cognitive Robotic System for Simple Surgical Tasks Invited Feature Article Riccardo Muradore1*, Paolo Fiorini1, Gokhan Akgun2, Duygun Erol Barkana3, Marcello Bonfe4, Fabrizio Boriero1, Andrea Caprara11, Giacomo De Rossi1, Riccardo Dodi5, Ole Jakob Elle6, Federica Ferraguti7, Lorenza Gasperotti1, Roger Gassert8, Kim Mathiassen6, Dilla Handini9, Olivier Lambercy8, Lin Li10, Maarja Kruusmaa10, Aura...

  6. A GPU Accelerated Spring Mass System for Surgical Simulation

    DEFF Research Database (Denmark)

    Mosegaard, Jesper; Sørensen, Thomas Sangild

    2005-01-01

    There is a growing demand for surgical simulators to dofast and precise calculations of tissue deformation to simulateincreasingly complex morphology in real-time. Unfortunately, evenfast spring-mass based systems have slow convergence rates for largemodels. This paper presents a method to accele...... to accelerate computation of aspring-mass system in order to simulate a complex organ such as theheart. This acceleration is achieved by taking advantage of moderngraphics processing units (GPU)....

  7. Adaptive lesion formation using dual mode ultrasound array system

    Science.gov (United States)

    Liu, Dalong; Casper, Andrew; Haritonova, Alyona; Ebbini, Emad S.

    2017-03-01

    We present the results from an ultrasound-guided focused ultrasound platform designed to perform real-time monitoring and control of lesion formation. Real-time signal processing of echogenicity changes during lesion formation allows for identification of signature events indicative of tissue damage. The detection of these events triggers the cessation or the reduction of the exposure (intensity and/or time) to prevent overexposure. A dual mode ultrasound array (DMUA) is used for forming single- and multiple-focus patterns in a variety of tissues. The DMUA approach allows for inherent registration between the therapeutic and imaging coordinate systems providing instantaneous, spatially-accurate feedback on lesion formation dynamics. The beamformed RF data has been shown to have high sensitivity and specificity to tissue changes during lesion formation, including in vivo. In particular, the beamformed echo data from the DMUA is very sensitive to cavitation activity in response to HIFU in a variety of modes, e.g. boiling cavitation. This form of feedback is characterized by sudden increase in echogenicity that could occur within milliseconds of the application of HIFU (see http://youtu.be/No2wh-ceTLs for an example). The real-time beamforming and signal processing allowing the adaptive control of lesion formation is enabled by a high performance GPU platform (response time within 10 msec). We present results from a series of experiments in bovine cardiac tissue demonstrating the robustness and increased speed of volumetric lesion formation for a range of clinically-relevant exposures. Gross histology demonstrate clearly that adaptive lesion formation results in tissue damage consistent with the size of the focal spot and the raster scan in 3 dimensions. In contrast, uncontrolled volumetric lesions exhibit significant pre-focal buildup due to excessive exposure from multiple full-exposure HIFU shots. Stopping or reducing the HIFU exposure upon the detection of such an

  8. Ultrasound Imaging of the Hepatobiliary System and Pancreas.

    Science.gov (United States)

    Larson, Martha Moon

    2016-05-01

    Ultrasound is an extremely valuable diagnostic modality for the diagnosis of hepatobiliary and pancreatic disease. Normal appearance and normal variations are important to understand to avoid misinterpretation. Although ultrasound can identify a lesion, cytology and histopathology are usually needed for a final diagnosis.

  9. [Lobectomy for lung cancer using the Da Vinci surgical system].

    Science.gov (United States)

    Nakamura, Hiroshige

    2014-05-01

    Robot-assisted surgery using the da Vinci surgical system has attracted attention because of excellent operability without shaking by joint forceps under the clear vision of a three-dimensional high-definition camera in lung cancer surgery. Although this form of advanced medical care is not yet approved for insurance coverage, it is at the stage of clinical research and expected to be useful in hilar exposure, lymph node dissection, and suturing of the lung parenchyma or bronchus. Lung cancer surgery with the da Vinci system has the advantage of combining thoracotomy and minimally invasive surgery in video-assisted thoracic surgery. However, safety management, education, and significant cost are problems to be resolved. Several important issues such as sharing knowledge and technology of robotic surgery, education, training, development of new instruments, and acquisition of advanced medical insurance are discussed for the future development of robotic surgical systems.

  10. A single FPGA-based portable ultrasound imaging system for point-of-care applications.

    Science.gov (United States)

    Kim, Gi-Duck; Yoon, Changhan; Kye, Sang-Bum; Lee, Youngbae; Kang, Jeeun; Yoo, Yangmo; Song, Tai-kyong

    2012-07-01

    We present a cost-effective portable ultrasound system based on a single field-programmable gate array (FPGA) for point-of-care applications. In the portable ultrasound system developed, all the ultrasound signal and image processing modules, including an effective 32-channel receive beamformer with pseudo-dynamic focusing, are embedded in an FPGA chip. For overall system control, a mobile processor running Linux at 667 MHz is used. The scan-converted ultrasound image data from the FPGA are directly transferred to the system controller via external direct memory access without a video processing unit. The potable ultrasound system developed can provide real-time B-mode imaging with a maximum frame rate of 30, and it has a battery life of approximately 1.5 h. These results indicate that the single FPGA-based portable ultrasound system developed is able to meet the processing requirements in medical ultrasound imaging while providing improved flexibility for adapting to emerging POC applications.

  11. The accuracy of ultrasound guided 14-gauge core needle breast biopsy: Correlation with surgical excision or long term follow-up

    Directory of Open Access Journals (Sweden)

    Sumaporn Makkun

    2011-09-01

    Full Text Available Objective: To determine the diagnostic accuracy of ultrasound-guided 14-gauge core-needle breast biopsy (CNB correlation with surgical excision or long term follow-up. Methods: One hundred and fifteen breast lesions which had undergone ultrasound-guided 14-gauge core-needle breast biopsy from May 2003 to Aug 2010 in the Breast Diagnostic Center, King Chulalongkorn Memorial Hospital were included in this study. Clinical history, palpability of the lesion, site of the lesion, the prebiopsy lesion size, ultrasound characteristic, level of suspicion according to the BIRADS classification, number of samples taken and pathologic results of CNB were reviewed and correlated with pathologic results of subsequent open surgery. For benign lesions without surgery, we correlated the result of CNB with stability of the lesion at or more than two-year interval follow-up. The accuracy rate, sensitivity, specificity, false positive rate, false negative rate, positive predictive value and negative predictive value were accessed. The falsenegative diagnoses of core needle biopsy were reviewed in detail. Procedural complications were also observed. Results: Among 115 lesions, 114 lesions were in female and 1 lesion was in male with their mean age of 50.87 years old (ranging from 27-72, 91 lesions were palpable (79.13%, 24 were non-palpable (20.87%. The prebiopsy size was 3.2 cm in diameter ranging from 0.5-20.0 cm. The pathologic results for the CNB were malignancy in 77.39% (89 lesions, high-risk in 0.87% (1 lesion and benign in 21.17% (25 lesions. Five patients were negative for malignancy by core needle biopsy but positive for malignancy by surgical procedure. The sensitivity was 94.68%. The specificity was 100%. The false negative rate was 5.3%. The positive predictive value was 100%. The negative predictive value was 80.76%. The accuracy was 95.65%. There was no false positive case. Conclusions: Core needle biopsy under ultrasound guidance is a minimally

  12. Robot-assisted ultrasound imaging: overview and development of a parallel telerobotic system.

    Science.gov (United States)

    Monfaredi, Reza; Wilson, Emmanuel; Azizi Koutenaei, Bamshad; Labrecque, Brendan; Leroy, Kristen; Goldie, James; Louis, Eric; Swerdlow, Daniel; Cleary, Kevin

    2015-02-01

    Ultrasound imaging is frequently used in medicine. The quality of ultrasound images is often dependent on the skill of the sonographer. Several researchers have proposed robotic systems to aid in ultrasound image acquisition. In this paper we first provide a short overview of robot-assisted ultrasound imaging (US). We categorize robot-assisted US imaging systems into three approaches: autonomous US imaging, teleoperated US imaging, and human-robot cooperation. For each approach several systems are introduced and briefly discussed. We then describe a compact six degree of freedom parallel mechanism telerobotic system for ultrasound imaging developed by our research team. The long-term goal of this work is to enable remote ultrasound scanning through teleoperation. This parallel mechanism allows for both translation and rotation of an ultrasound probe mounted on the top plate along with force control. Our experimental results confirmed good mechanical system performance with a positioning error of < 1 mm. Phantom experiments by a radiologist showed promising results with good image quality.

  13. Computerized Ultrasound Risk Evaluation (CURE) System: Development of Combined Transmission and Reflection Ultrasound with New Reconstruction Algorithms for Breast Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Littrup, P J; Duric, N; Azevedo, S; Chambers, D; Candy, J V; Johnson, S; Auner, G; Rather, J; Holsapple, E T

    2001-09-07

    Our Computerized Ultrasound Risk Evaluation (CURE) system has been developed to the engineering prototype stage and generated unique data sets of both transmission and reflection ultrasound (US). This paper will help define the clinical underpinnings of the developmental process and interpret the imaging results from a similar perspective. The CURE project was designed to incorporate numerous diagnostic parameters to improve upon two major areas of early breast cancer detection. CURE may provide improved tissue characterization of breast masses and reliable detection of abnormal microcalcifications found in some breast cancers and ductal carcinoma in situ (DCIS). Current breast US is limited to mass evaluation, whereas mammography also detects and guides biopsy of malignant calcifications. Screening with CURE remains a distant goal, but improved follow-up of mammographic abnormalities may represent a feasible breakthrough. Improved tissue characterization could result in reduction of the estimated one million benign biopsies each year in the United States, costing up to several billion dollars. Most breast calcifications are benign and comprise-80% of stereotactic biopsies guided by mammography. Ultrasound has the capability of finding some groups of calcifications, but further improvements in resolution should also address tissue characterization to define the soft tissue filling of ducts by DCIS. In this manner, CURE may be able to more accurately identify the malignant calcifications associated with progression of DCIS or early cancers. Currently, high-resolution US images of the breast are performed in the reflection mode at higher frequencies, which also limits depth of penetration. Reconstruction of reflection ultrasound images relies upon acoustic impedance differences in the tissue and includes only direct backscatter of the ultrasound signal. Resolution and tissue contrast of current US continues to improve with denser transducer arrays and image

  14. Can Sarcopenia Quantified by Ultrasound of the Rectus Femoris Muscle Predict Adverse Outcome of Surgical Intensive Care Unit Patients as well as Frailty? A Prospective, Observational Cohort Study.

    Science.gov (United States)

    Mueller, Noomi; Murthy, Sushila; Tainter, Christopher R; Lee, Jarone; Riddell, Kathleen; Fintelmann, Florian J; Grabitz, Stephanie D; Timm, Fanny P; Levi, Benjamin; Kurth, Tobias; Eikermann, Matthias

    2016-12-01

    To compare sarcopenia and frailty for outcome prediction in surgical intensive care unit (SICU) patients. Frailty has been associated with adverse outcomes and describes a status of muscle weakness and decreased physiological reserve leading to increased vulnerability to stressors. However, frailty assessment depends on patient cooperation. Sarcopenia can be quantified by ultrasound and the predictive value of sarcopenia at SICU admission for adverse outcome has not been defined. We conducted a prospective, observational study of SICU patients. Sarcopenia was diagnosed by ultrasound measurement of rectus femoris cross-sectional area. Frailty was diagnosed by the Frailty Index Questionnaire based on 50 variables. Relationship between variables and outcomes was assessed by multivariable regression analysis NCT02270502. Sarcopenia and frailty were quantified in 102 patients and observed in 43.1% and 38.2%, respectively. Sarcopenia predicted adverse discharge disposition (discharge to nursing facility or in-hospital mortality, odds ratio 7.49; 95% confidence interval 1.47-38.24; P = 0.015) independent of important clinical covariates, as did frailty (odds ratio 8.01; 95% confidence interval 1.82-35.27; P = 0.006); predictive ability did not differ between sarcopenia and frailty prediction model, reflected by χ values of 21.74 versus 23.44, respectively, and a net reclassification improvement (NRI) of -0.02 (P = 0.87). Sarcopenia and frailty predicted hospital length of stay and the frailty model had a moderately better predictive accuracy for this outcome. Bedside diagnosis of sarcopenia by ultrasound predicts adverse discharge disposition in SICU patients equally well as frailty. Sarcopenia assessed by ultrasound may be utilized as rapid beside modality for risk stratification of critically ill patients.

  15. The Effects of Ultrasound on Biological Systems: Site

    Science.gov (United States)

    El-Karmi, Anan M.

    Earlier studies (Dinno et al., Ultrasound Med. Biol. 15:461 -470; 1989) demonstrated that ultrasound at therapeutic intensities causes large increases in total conductance (G_{rm t}) of frog skin. These changes were attributed to non-thermal mechanisms, primarily, cavitation. In this study, the site(s) and mechanism(s) of action of ultrasound for the increase in G_{rm t} were examined. The reversible changes in G_{rm t } and sodium current were monitored in real time as a function of ultrasound exposure. Amiloride, a sodium channel blocker, was used to differentiate between cellular (G_{rm c}) and paracellular (G_{rm s}) pathways in the presence and absence of ultrasound. No significant changes were detected in G_ {rm c}. However, changes in G _{rm s} were significant. These results demonstrate that most of the increase in G _{rm t} due to ultrasound is taking place in the paracellular pathways. Sodium channels were not significantly affected by ultrasound. Thus, the changes in G_{rm c} are not specific. The effects of ultrasound were examined in the presence of radical scavengers and antioxidants. The increase in G_{rm t} due to ultrasound was significantly minimized in the presence of cystamine, cysteamine, and sodium ascorbate. This demonstrates that free radicals and other reactive species generated by cavitation are causing the increase in G_ {rm t}, possibly by acting from inside the cells. Radical scavengers and antioxidants are providing protection from oxidative damage but are not involved in the recovery of G_{ rm t} towards steady state values after sonication. The role of Ca^{2+} in the effects of ultrasound was examined since many of the cellular reactions involved in tissue recovery are dependent on the intracellular availability of free Ca^{2+}. The percentage increase in G_{rm t} in the presence of Ca^{2+} was larger than in its absence (140% vs. 27%). The time constant for G_{rm t} to return to steady state was longer in calcium-free solutions (122

  16. Absorption of ultrasound waves during dynamic processes in disperse systems

    Science.gov (United States)

    Kol'tsova, I. S.; Khomutova, A. S.

    2016-11-01

    Measurements of ultrasound wave absorption are conducted at a frequency of 3 MHz in 3% suspensions of starch, gelatin, and lactose. It is shown that the dynamics of the additional ultrasound wave absorption coefficient in the suspensions carries information on the processes of swelling, dissolution, and the phase and structural periods occurring in the interaction of the disperse and dispersoid phases; it also reflects the influence of the temperature field on these processes.

  17. Head-mounted display system for surgical visualization

    Science.gov (United States)

    Schmidt, Greg W.; Osborn, Dale B.

    1995-05-01

    Recent advances in high resolution color spatial light modulators and light weight optics together with application specific integrated circuits enable true stereoscopic visualization on a head mounted display (HMD). The development of precision stereo displays with comfortable long duration wear characteristics are critically dependent on incorporating key human factors into the HMD design. In this paper we discuss the development of a VGA format (640 X 480 pixel) full color video and graphics stereo display. Its primary application is as an element of an integrated, interactive visualization system for surgeons performing minimally invasive surgery and endoscopic laser surgery. Additional uses include endoscopic and open surgical training and rehearsal. The high resolution, wide field of view displays combined with true stereoscopic imagery enhances the surgeon's visualization, ability to navigate and manipulate in the surgical field.

  18. Development of a PET-Transrectal Ultrasound Prostate Imaging System

    Science.gov (United States)

    Huber, Jennifer S.; Peng, Qiyu.; Moses, William W.; Reutter, Bryan W.; Pouliot, Jean; Hsu, I. Chow

    2011-06-01

    Multimodality imaging has an increasing role in the management of a large number of diseases, particularly if both functional and structural information are acquired and accurately registered. Transrectal ultrasound (TRUS) imaging is currently an integral part of prostate cancer diagnosis and treatment procedures, providing high-resolution anatomical detail of the prostate region. Positron Emission Tomography (PET) imaging with 11C-choline is a sensitive functional imaging technique that can identify biochemical states associated with prostate cancer. We believe that merging these prostate imaging technologies will help identify the location and aggressiveness of prostate cancer. We envision using dual PET-TRUS prostate imaging to guide biopsy, guide treatment procedures, and detect local recurrence earlier than is currently possible. Hence, we have developed a dual PET-TRUS prostate imaging system and protocol designed to allow accurate 3-D image registration. We have evaluated this PET-TRUS system by performing dual PET-TRUS imaging of custom phantoms. We describe here our dual-modality imaging system, custom phantoms and phantom study results. We also discuss our investigation of the PET-TRUS registration accuracy. We measure an average PET-TRUS registration error for our phantom studies of 2.1 ±1.7 mm in the x direction, 1.9 ±1.6 mm in the y direction, and 0.6 ±0.2 mm in the z direction. This registration accuracy is sufficient for some clinical applications such as biopsy guidance and early detection of recurrence.

  19. [Norfloxacin Solution Degradation Under Ultrasound, Potassium Persulfate Collaborative System].

    Science.gov (United States)

    Wei, Hong; Shi, Jing-zhuan; Li, Jia-lin; Li, Ke-bin; Zhao, Lin; Han, Kai

    2015-11-01

    High oxidative sulfate radicals can be produced by potassium persulfate (K2S2O8). The integrated effect of ultrasonic and K2S2O8, on norfloxacin degradation was investigated. The experimental parameters such as K2S2O8 concentration, norfloxacin initial concentration, initial pH value, free radicals quenching agents such as methanol and tert-butyl on norfloxacin degradation were discussed. The results indicated that ultrasonic/K2S2O8, system had an obvious degradation and mineralization effect on norfloxacin. Norfloxacin removal efficiencies were 3.2 and 8.9 times in ultrasonic/K2S2O8 system than those in single K252O8 and ultrasonic oxidation system, respectively. And the reaction followed the first-order kinetics. Norfloxacin removal efficiency varied gently with K2S2O8 concentration. Solution initial pH had a significant effect on norfloxacin degradation, which was attributed to the different oxidizing species under different pH values. The radicals were sulfate radicals under acidic and neutral conditions, and was the combination of sulfate and hydroxyl radicals under alkaline conditions. TOC and agar diffusion test with E. coli showed that 49.12% norfloxacin was mineralized and antibacterial activity was completely removed, with the diameter of E. coli inhibition zone decreased from 45 mm to 14 mm (filter paper diameter). The result implied that ultrasound/K2S2O8 showed promising results as a possible application for treatment of norfloxacin antibiotics wastewater.

  20. Three-dimensional ultrasound system for guided breast brachytherapy.

    Science.gov (United States)

    De Jean, Paul; Beaulieu, Luc; Fenster, Aaron

    2009-11-01

    Breast-conserving surgery combined with subsequent radiation therapy is a standard procedure in breast cancer treatment. The disadvantage of whole-breast beam irradiation is that it requires 20-25 treatment days, which is inconvenient for patients with limited mobility or who reside far from the treatment center. However, interstitial high-dose-rate (HDR) brachytherapy is an irradiation method requiring only 5 treatment days and that delivers a lower radiation dose to the surrounding healthy tissue. It involves delivering radiation through 192Ir seeds placed inside the catheters, which are inserted into the breast. The catheters are attached to a HDR afterloader, which controls the seed placement within the catheters and irradiation times to deliver the proper radiation dose. One disadvantage of using HDR brachytherapy is that it requires performing at least one CT scan during treatment planning. The procedure at our institution involves the use of two CT scans. Performing CT scans requires moving the patient from the brachytherapy suite with catheters inserted in their breasts. One alternative is using three-dimensional ultrasound (3DUS) to image the patient. In this study, the authors developed a 3DUS translation scanning system for use in breast brachytherapy. The new system was validated using CT, the current clinical standard, to image catheters in a breast phantom. Once the CT and 3DUS images were registered, the catheter trajectories were then compared. The results showed that the average angular separation between catheter trajectories was 2.4 degrees, the average maximum trajectory separation was 1.0 mm, and the average mean trajectory separation was found to be 0.7 mm. In this article, the authors present the 3DUS translation scanning system's capabilities as well as its potential to be used as the primary treatment planning imaging modality in breast brachytherapy.

  1. Duplex ultrasound

    Science.gov (United States)

    Vascular ultrasound; Peripheral vascular ultrasound ... A duplex ultrasound combines: Traditional ultrasound: This uses sound waves that bounce off blood vessels to create pictures. Doppler ultrasound: This ...

  2. Uterine Length in Adolescents with Developmental Disability: Are Ultrasound Examinations Necessary before Insertion of the Levonorgestrel Intrauterine System?

    Science.gov (United States)

    Whyte, Helena; Pecchioli, Yael; Oyewumi, Lamide; Kives, Sari; Allen, Lisa M; Kirkham, Yolanda A

    2016-12-01

    (1) To determine if there are any differences in uterine length between adolescents with developmental disability (DD) compared with their normally developing (ND) peers that might necessitate ultrasonography before insertion of levonorgestrel intrauterine system (LNG-IUS) in patients with DD; and (2) to characterize the LNG-IUS insertion procedure in adolescents with disabilities. This was a retrospective cohort study of 223 female adolescents with or without DDs. Seventy-five adolescents had DD; 33 underwent intrauterine system insertion in the operating room and 42 did not. A comparative cohort of 148 ND adolescents who had pelvic ultrasound examinations for abnormal uterine bleeding were included. The study period was between January 2006 and July 2013 at the Hospital for Sick Children, Toronto, Canada. Cases were identified from surgical databases and medical records. Mean uterine length on pelvic ultrasound, demographic characteristics (age, age at menarche, time from menarche to ultrasound, weight), and descriptive statistics on intrauterine system insertion. There was a statistically significant difference (P = .03) in uterine length between adolescents with and without DD (6.7 vs 7.1 cm). However, this was not a clinically significant difference because insertion of the LNG-IUS in patients with DD was successful in patients with uteri more than 5 cm long. There was no difference (P = .97) in uterine length of adolescents with DD whether they had LNG-IUS insertion or not (6.7 cm). Adolescents with DD were younger than adolescents without DD at time of ultrasound examination (P = .01). However, among patients with DD, those who underwent intrauterine system insertion were older (P = .001). Incidence of uterine anomaly in patients with DD is low (2.7%) and was the same as in ND adolescents. Rates of complications and expulsions were low and there were no failures of LNG-IUS insertion in adolescents with DD. Routine pelvic ultrasound examinations

  3. Systemic inflammation worsens outcomes in emergency surgical patients.

    Science.gov (United States)

    Becher, Robert D; Hoth, J Jason; Miller, Preston R; Meredith, J Wayne; Chang, Michael C

    2012-05-01

    Acute care surgeons are uniquely aware of the importance of systemic inflammatory response and its influence on postoperative outcomes; concepts like damage control have evolved from this experience. For surgeons whose practice is mostly elective, the significance of such systemic inflammation may be underappreciated. This study sought to determine the influence of preoperative systemic inflammation on postoperative outcome in patients requiring emergent colon surgery. Emergent colorectal operations were identified in the American College of Surgeons National Surgical Quality Improvement Program 2008 dataset. Four groups were defined by the presence and magnitude of the inflammatory response before operation: no inflammation, systemic inflammatory response syndrome (SIRS), sepsis, or severe sepsis/septic shock. Thirty-day survival was analyzed by Kaplan-Meier method. A total of 3,305 patients were identified. Thirty-day survival was significantly different (p SIRS was 1.9 (p SIRS or sepsis patients, operations surgery. II, prognostic study.

  4. Performance Evaluation of a Synthetic Aperture Real-Time Ultrasound System

    DEFF Research Database (Denmark)

    Stuart, Matthias Bo; Tomov, Borislav Gueorguiev; Jensen, Jørgen Arendt

    2011-01-01

    This paper evaluates the signal-to-noise ratio, the time stability, and the phase difference of the sampling in the experimental ultrasound scanner SARUS: A synthetic aperture, real-time ultrasound system. SARUS has 1024 independent transmit and receive channels and is capable of handling 2D probes...... for 3D ultrasound imaging. It samples at 12 bits per sample and has a sampling rate of 70 MHz with the possibility of decimating the sampling frequency at the input. SARUS is capable of advanced real-time computations such as synthetic aperture imaging. The system is built using fieldprogrammable gate...... arrays (FPGAs) making it very flexible and allowing implementation of other real-time ultrasound processing methods in the future. For conventional B-mode imaging, a penetration depth around 7 cm for a 7 MHz transducer is obtained (signal-tonoise ratio of 0 dB), which is comparable to commercial...

  5. PLUS: open-source toolkit for ultrasound-guided intervention systems.

    Science.gov (United States)

    Lasso, Andras; Heffter, Tamas; Rankin, Adam; Pinter, Csaba; Ungi, Tamas; Fichtinger, Gabor

    2014-10-01

    A variety of advanced image analysis methods have been under the development for ultrasound-guided interventions. Unfortunately, the transition from an image analysis algorithm to clinical feasibility trials as part of an intervention system requires integration of many components, such as imaging and tracking devices, data processing algorithms, and visualization software. The objective of our paper is to provide a freely available open-source software platform-PLUS: Public software Library for Ultrasound-to facilitate rapid prototyping of ultrasound-guided intervention systems for translational clinical research. PLUS provides a variety of methods for interventional tool pose and ultrasound image acquisition from a wide range of tracking and imaging devices, spatial and temporal calibration, volume reconstruction, simulated image generation, and recording and live streaming of the acquired data. This paper introduces PLUS, explains its functionality and architecture, and presents typical uses and performance in ultrasound-guided intervention systems. PLUS fulfills the essential requirements for the development of ultrasound-guided intervention systems and it aspires to become a widely used translational research prototyping platform. PLUS is freely available as open source software under BSD license and can be downloaded from http://www.plustoolkit.org.

  6. An improved MRI guided ultrasound system for superficial tumor hyperthermia

    Science.gov (United States)

    Zhu, Mengyuan; Shen, Guofeng; Su, Zhiqiang; Chen, Sheng; Wu, Hao

    2017-03-01

    Among many methods in tumor treatment, ultrasound hyperthermia is characterized by non-invasiveness, and it has been proven very effective for clinical treatment. But the problem of monitoring temperature limits its development. MRI-based temperature mapping techniques are safe compared with invasive methods and have been applied to detect temperature changes for a variety of applications. Among these techniques, the proton resonance frequency (PRF) method is relatively advanced. With a temperature measuring experiment and experiment conducted on tumors inside rabbit legs, the effectiveness of PRF method has been proved. This paper is to introduce an MRI guided ultrasound superficial tumor hyperthermia instrument based on PRF method.

  7. Clinical neurosonography. Ultrasound of the central nervous system

    Energy Technology Data Exchange (ETDEWEB)

    Naidich, T.P.; Quencer, R.M.

    1987-01-01

    Neurosonography is the application of ultrasound technology to the diagnosis and follow-up of lesions of the brain and meninges, spinal cord and canal, carotid arteries, eye and orbit. The authors of this book have reviewed neurosonography in separate sections on fetal neurosonography, the neonate head, the neonatal spine, intraoperative neurosonography, post-operative neurosonography, carotid sonography, and orbital echography. In each section, the authors discuss basic diagnosis, present recent advances in the area. The contents discussed are: Fetal neurosonography. - The neonatal head. - The neonatal spine. - Intraopertive neurosonography. - Post-operative neurosonography. - Duplex carotid ultrasound. - Orbital echography. Subject Index.

  8. Design, Implementation and Testing of Master Slave Robotic Surgical System

    Directory of Open Access Journals (Sweden)

    Syed Amjad Ali

    2015-01-01

    Full Text Available The autonomous manipulation of the medical robotics is needed to draw up a complete surgical plan in development. The autonomy of the robot comes from the fact that once the plan is drawn up off-line, it is the servo loops, and only these, that control the actions of the robot online, based on instantaneous control signals and measurements provided by the vision or force sensors. Using only these autonomous techniques in medical and surgical robotics remain relatively limited for two main reasons: Predicting complexity of the gestures, and human Safety. Therefore, Modern research in haptic force feedback in medical robotics is aimed to develop medical robots capable of performing remotely, what a surgeon does by himself. These medical robots are supposed to work exactly in the manner that a surgeon does in daily routine. In this paper the master slave tele-robotic system is designed and implemented with accuracy and stability by using 6DOF (Six Degree of Freedom haptic force feedback devices. The master slave control strategy, haptic devices integration, application software designing using Visual C++ and experimental setup are considered. Finally, results are presented the stability, accuracy and repeatability of the system

  9. Systemic inflammatory response syndrome and surgical stress in thoracic surgery.

    Science.gov (United States)

    Takenaka, Kazumasa; Ogawa, Eiji; Wada, Hiromi; Hirata, Toshiki

    2006-03-01

    To evaluate the clinical usefulness of postoperative systemic inflammatory response syndrome (SIRS) as an index of surgical stress in patients undergoing thoracic surgery. Forty-five consecutive patients who underwent thoracic surgery with thoracotomy were enrolled. The SIRS criteria were examined daily during the first 7 postoperative days. The serum interleukin-6 (IL-6) level, operation time, intraoperative blood loss, amount of thoracic drainage, and C-reactive protein levels were also measured. Sixteen cases were categorized into the SIRS group, whereas 29 cases were categorized into the non-SIRS group. Among the patients who underwent thoracic surgery, the physiological responses of the patients to the surgery, such as serum IL-6 levels and C-reactive protein levels, were significantly higher in the SIRS group than in the non-SIRS group (P = .002 and .024, respectively). The serum IL-6 level on the first postoperative day was an independent factor associated with SIRS (95% CI 1.002-1.041; P = .030). Furthermore, there was a correlation between the number of SIRS days and the duration of the postoperative hospital stay (r = 0.379, P = .012). Our results demonstrated that SIRS reflected the degree of surgical stress, especially thoracotomic procedures, through the IL-6 levels, and affected the postoperative hospital stay. Systemic inflammatory response syndrome can be useful for the postoperative management of patients undergoing thoracic surgery.

  10. Protection circuits for very high frequency ultrasound systems.

    Science.gov (United States)

    Choi, Hojong; Shung, K Kirk

    2014-04-01

    The purpose of protection circuits in ultrasound applications is to block noise signals from the transmitter from reaching the transducer and also to prevent unwanted high voltage signals from reaching the receiver. The protection circuit using a resistor and diode pair is widely used due to its simple architecture, however, it may not be suitable for very high frequency (VHF) ultrasound transducer applications (>100 MHz) because of its limited bandwidth. Therefore, a protection circuit using MOSFET devices with unique structure is proposed in this paper. The performance of the designed protection circuit was compared with that of other traditional protection schemes. The performance characteristics measured were the insertion loss (IL), total harmonic distortion (THD) and transient response time (TRT). The new protection scheme offers the lowest IL (-1.0 dB), THD (-69.8 dB) and TRT (78 ns) at 120 MHz. The pulse-echo response using a 120 MHz LiNbO3 transducer with each protection circuit was measured to validate the feasibility of the protection circuits in VHF ultrasound applications. The sensitivity and bandwidth of the transducer using the new protection circuit improved by 252.1 and 50.9 %, respectively with respect to the protection circuit using a resistor and diode pair. These results demonstrated that the new protection circuit design minimizes the IL, THD and TRT for VHF ultrasound transducer applications.

  11. Musculoskeletal ultrasound on the hand and wrist in systemic sclerosis

    Directory of Open Access Journals (Sweden)

    Rasha M Fawzy

    2016-01-01

    Conclusion Ultrasound was more accurate than clinical examination and conventional radiography in the detection of subclinical synovitis, tenosynovitis, and the underlying fibrotic changes of tendon friction rub. In SSc patients, on using MSUS, articular involvement was found to be less frequent compared with that in RA patients, with specific appearance of sclerosing tenosynovitis in SSc patients.

  12. Treatment of Glioma Using neuroArm Surgical System

    Directory of Open Access Journals (Sweden)

    Yaser Maddahi

    2016-01-01

    Full Text Available The use of robotic technology in the surgical treatment of brain tumour promises increased precision and accuracy in the performance of surgery. Robotic manipulators may allow superior access to narrow surgical corridors compared to freehand or conventional neurosurgery. This paper reports values and ranges of tool-tissue interaction forces during the performance of glioma surgery using an MR compatible, image-guided neurosurgical robot called neuroArm. The system, capable of microsurgery and stereotaxy, was used in the surgical resection of glioma in seven cases. neuroArm is equipped with force sensors at the end-effector allowing quantification of tool-tissue interaction forces and transmits force of dissection to the surgeon sited at a remote workstation that includes a haptic interface. Interaction forces between the tool tips and the brain tissue were measured for each procedure, and the peak forces were quantified. Results showed maximum and minimum peak force values of 2.89 N (anaplastic astrocytoma, WHO grade III and 0.50 N (anaplastic oligodendroglioma, WHO grade III, respectively, with the mean of peak forces varying from case to case, depending on type of the glioma. Mean values of the peak forces varied in range of 1.27 N (anaplastic astrocytoma, WHO grade III to 1.89 N (glioblastoma with oligodendroglial component, WHO grade IV. In some cases, ANOVA test failed to reject the null hypothesis of equality in means of the peak forces measured. However, we could not find a relationship between forces exerted to the pathological tissue and its size, type, or location.

  13. Discrete echo signal modeling of ultrasound imaging systems

    Science.gov (United States)

    Chen, Ming; Zhang, Cishen

    2008-03-01

    In this paper, a discrete model representing the pulse-tissue interaction in the medical ultrasound scanning and imaging process is developed. The model is based on discretizing the acoustical wave equation and is in terms of convolution between the input ultrasound pulses and the tissue mass density variation. Such a model can provide a useful means for ultrasound echo signal processing and imaging. Most existing models used for ultrasound imaging are based on frequency domain transform. A disadvantage of the frequency domain transform is that it is only applicable to shift-invariant models. Thus it has ignored the shift-variant nature of the original acoustic wave equation where the tissue compressibility and mass density distributions are spatial-variant factors. The discretized frequency domain model also obscures the compressibility and mass density representations of the tissue, which may mislead the physical understanding and interpretation of the image obtained. Moreover, only the classical frequency domain filtering methods have been applied to the frequency domain model for acquiring some tissue information from the scattered echo signals. These methods are non-parametric and require a prior knowledge of frequency spectra of the transmitted pulses. Our proposed model technique will lead to discrete, multidimensional, shift-variant and parametric difference or convolution equations with the transmitted pulse pressure as the input, the measurement data of the echo signals as the output, and functions of the tissue compressibility and mass density distributions as shift-variant parameters that can be readily identified from input-output measurements. The proposed model represents the entire multiple scattering process, and hence overcomes the key limitation in the current ultrasound imaging methods.

  14. Ultrasound assisted combustion synthesis of TiC in Al-Ti-C system.

    Science.gov (United States)

    Liu, Zhiwei; Rakita, Milan; Xu, Wilson; Wang, Xiaoming; Han, Qingyou

    2015-11-01

    This research investigated the effects of high-intensity ultrasound on the combustion synthesis of TiC particles in Al-Ti-C system. The process involved that high-intensity ultrasound was applied on the surface of a compacted Al-Ti-C pellet directly through a Nb probe during the thermal explosion reaction. By comparing with the sample without ultrasonic treatment, it was found that the thermal explosion reaction for synthesizing TiC phase could take place thoroughly in the ultrasonically treated sample. During the process of synthesizing TiC phase, the dissolution of solid graphite particles into the Al-Ti melt, as well as the nucleation and growth of TiC particles could be promoted effectively due to the effects of ultrasound, leading to an enhancement of the formation of TiC particles. Ultrasound assisted combustion synthesis as a simple and effective approach was proposed for synthesizing materials in this research.

  15. Ultrasound transducer assembly and method for manufacturing an ultrasound transducer assembly

    NARCIS (Netherlands)

    Dekker, R.; Henneken, V.A.; Louwerse, M.C.; Raganato, M.F.

    2015-01-01

    The present invention relates to an ultrasound transducer assembly (10), in particular for intravascular ultrasound systems. The ultrasound transducer assembly comprises at least one silicon substrate element (30) including an ultrasound transducer element (14) for emitting and receiving ultrasound

  16. Ultrasound transducer assembly and method for manufacturing an ultrasound transducer assembly

    NARCIS (Netherlands)

    Dekker, R.; Henneken, V.A.; Louwerse, M.C.; Raganato, M.F.

    2015-01-01

    The present invention relates to an ultrasound transducer assembly (10), in particular for intravascular ultrasound systems. The ultrasound transducer assembly comprises at least one silicon substrate element (30) including an ultrasound transducer element (14) for emitting and receiving ultrasound

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... frequently used to evaluate the reproductive and urinary systems. Ultrasound is safe, noninvasive and does not use ... and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. ...

  18. Ultrasound-based servoing of manipulators for telesurgery

    Science.gov (United States)

    Stoll, Jeff; Dupont, Pierre; Howe, Robert D.

    2002-02-01

    Certain minimally invasive surgical procedures involve the treatment of highly precise target locations within deformable tissues. While preoperative MRI and CT models can be used for surgical planning, they provide only coarse guidance during surgery due to their limited resolution and owing to tissue deformation. Ultrasound imaging is a promising means of obtaining real-time intraoperative data for target localization that is particularly well suited to minimally invasive surgery due to its portability, speed, and safety. This paper presents a system, in which ultrasound images are used to guide a manipulator to a surgical site. Electromagnetic tracking of the ultrasound probe is used to orient the images. These are then segmented in real time to determine target locations. Finally, target coordinates are used to produce control inputs to drive the manipulator to the target site. The potential of the approach is demonstrated experimentally using a manipulator arm, phantom target, and commercial ultrasound machine.

  19. Instrumentation of the da Vinci Robotic Surgical System

    DEFF Research Database (Denmark)

    Hansen, Karl Damkjær; Jensen, Simon; Sloth, Christoffer

    2015-01-01

    This paper details the AAU surgical robot, its hardware and software setup. The aim of the paper is to explain how a surgical robot has been rebuild as an open source platform for research in surgical robotics. As a result, the robot has full actuation and sensing capabilities at high sampling ra....... We aim at exploiting the developed surgical robot for research in semi-autonomous control, and safety mechanisms in the context of robotic surgery.......This paper details the AAU surgical robot, its hardware and software setup. The aim of the paper is to explain how a surgical robot has been rebuild as an open source platform for research in surgical robotics. As a result, the robot has full actuation and sensing capabilities at high sampling rate...

  20. Instrumentation of the da Vinci Robotic Surgical System

    DEFF Research Database (Denmark)

    Hansen, Karl Damkjær; Jensen, Simon; Sloth, Christoffer

    2015-01-01

    This paper details the AAU surgical robot, its hardware and software setup. The aim of the paper is to explain how a surgical robot has been rebuild as an open source platform for research in surgical robotics. As a result, the robot has full actuation and sensing capabilities at high sampling ra....... We aim at exploiting the developed surgical robot for research in semi-autonomous control, and safety mechanisms in the context of robotic surgery.......This paper details the AAU surgical robot, its hardware and software setup. The aim of the paper is to explain how a surgical robot has been rebuild as an open source platform for research in surgical robotics. As a result, the robot has full actuation and sensing capabilities at high sampling rate...

  1. An Ultrasound Imaging-Guided Robotic HIFU Ablation Experimental System and Accuracy Evaluations

    Directory of Open Access Journals (Sweden)

    Chih Yu An

    2017-01-01

    Full Text Available In recent years, noninvasive thermal treatment by using high-intensity focused ultrasound (HIFU has high potential in tumor treatment. The goal of this research is to develop an ultrasound imaging-guided robotic HIFU ablation system for tumor treatment. The system integrates the technologies of ultrasound image-assisted guidance, robotic positioning control, and HIFU treatment planning. With the assistance of ultrasound image guidance technology, the tumor size and location can be determined from ultrasound images as well as the robotic arm can be controlled to position the HIFU transducer to focus on the target tumor. After the development of the system, several experiments were conducted to measure the positioning accuracy of this system. The results show that the average positioning error is 1.01 mm with a standard deviation 0.34, and HIFU ablation accuracy is 1.32 mm with a standard deviation 0.58, which means this system is confirmed with its possibility and accuracy.

  2. A model system and technique to study the effects of ultrasound irradiation on embryonic development.

    Science.gov (United States)

    Rosenthal, M S; Yip, Y P; Capriotti, C; Yip, J W

    1991-08-01

    To study the effects of ultrasound on development it is important to have a system which provides reliable results. We have designed a system which allows for reproducible irradiations of chick embryos in ovo. The irradiation system includes a heated sonation tank with ultrasound absorbers and a PC/AT computer-based data acquisition system for on-line monitoring of irradiations. The ultrasound detection microprobe and irradiation transducers were calibrated against an NBS traceable balance meter. An acoustic spacer was utilized to provide a more uniform profile of the irradiation beam. At the position of the embryo the ultrasound field geometry was determined. To maintain the chick embryo in its natural physiological state while minimizing ultrasonic reflections and standing-wave generation, two diametrically opposed windows were made in the eggshell along the ultrasound pathway and covered with polyethylene membranes. Using this irradiation system at intensity levels as high as 1.1 W/cm2 (spatial average, temporal average) for 10 min, the temperature rise is minimal.

  3. A Wearable Goggle Navigation System for Dual-Mode Optical and Ultrasound Localization of Suspicious Lesions: Validation Studies Using Tissue-Simulating Phantoms and an Ex Vivo Human Breast Tissue Model.

    Science.gov (United States)

    Zhang, Zeshu; Pei, Jing; Wang, Dong; Gan, Qi; Ye, Jian; Yue, Jian; Wang, Benzhong; Povoski, Stephen P; Martin, Edward W; Hitchcock, Charles L; Yilmaz, Alper; Tweedle, Michael F; Shao, Pengfei; Xu, Ronald X

    2016-01-01

    Surgical resection remains the primary curative treatment for many early-stage cancers, including breast cancer. The development of intraoperative guidance systems for identifying all sites of disease and improving the likelihood of complete surgical resection is an area of active ongoing research, as this can lead to a decrease in the need of subsequent additional surgical procedures. We develop a wearable goggle navigation system for dual-mode optical and ultrasound imaging of suspicious lesions. The system consists of a light source module, a monochromatic CCD camera, an ultrasound system, a Google Glass, and a host computer. It is tested in tissue-simulating phantoms and an ex vivo human breast tissue model. Our experiments demonstrate that the surgical navigation system provides useful guidance for localization and core needle biopsy of simulated tumor within the tissue-simulating phantom, as well as a core needle biopsy and subsequent excision of Indocyanine Green (ICG)-fluorescing sentinel lymph nodes. Our experiments support the contention that this wearable goggle navigation system can be potentially very useful and fully integrated by the surgeon for optimizing many aspects of oncologic surgery. Further engineering optimization and additional in vivo clinical validation work is necessary before such a surgical navigation system can be fully realized in the everyday clinical setting.

  4. A Wearable Goggle Navigation System for Dual-Mode Optical and Ultrasound Localization of Suspicious Lesions: Validation Studies Using Tissue-Simulating Phantoms and an Ex Vivo Human Breast Tissue Model.

    Directory of Open Access Journals (Sweden)

    Zeshu Zhang

    Full Text Available Surgical resection remains the primary curative treatment for many early-stage cancers, including breast cancer. The development of intraoperative guidance systems for identifying all sites of disease and improving the likelihood of complete surgical resection is an area of active ongoing research, as this can lead to a decrease in the need of subsequent additional surgical procedures. We develop a wearable goggle navigation system for dual-mode optical and ultrasound imaging of suspicious lesions. The system consists of a light source module, a monochromatic CCD camera, an ultrasound system, a Google Glass, and a host computer. It is tested in tissue-simulating phantoms and an ex vivo human breast tissue model. Our experiments demonstrate that the surgical navigation system provides useful guidance for localization and core needle biopsy of simulated tumor within the tissue-simulating phantom, as well as a core needle biopsy and subsequent excision of Indocyanine Green (ICG-fluorescing sentinel lymph nodes. Our experiments support the contention that this wearable goggle navigation system can be potentially very useful and fully integrated by the surgeon for optimizing many aspects of oncologic surgery. Further engineering optimization and additional in vivo clinical validation work is necessary before such a surgical navigation system can be fully realized in the everyday clinical setting.

  5. Experimental ultrasound system for real-time synthetic imaging

    OpenAIRE

    1999-01-01

    Digital signal processing is being employed more and more in modern ultrasound scanners. This has made it possible to do dynamic receive focusing for each sample and implement other advanced imaging methods. The processing, however, has to be very fast and cost-effective at the same time. Dedicated chips are used in order to do real time processing. This often makes it difficult to implement radically different imaging strategies on one platform and makes the scanners less accessible for rese...

  6. In-line positioning of ultrasound images using wireless remote display system with tablet computer facilitates ultrasound-guided radial artery catheterization.

    Science.gov (United States)

    Tsuchiya, Masahiko; Mizutani, Koh; Funai, Yusuke; Nakamoto, Tatsuo

    2016-02-01

    Ultrasound-guided procedures may be easier to perform when the operator's eye axis, needle puncture site, and ultrasound image display form a straight line in the puncture direction. However, such methods have not been well tested in clinical settings because that arrangement is often impossible due to limited space in the operating room. We developed a wireless remote display system for ultrasound devices using a tablet computer (iPad Mini), which allows easy display of images at nearly any location chosen by the operator. We hypothesized that the in-line layout of ultrasound images provided by this system would allow for secure and quick catheterization of the radial artery. We enrolled first-year medical interns (n = 20) who had no prior experience with ultrasound-guided radial artery catheterization to perform that using a short-axis out-of-plane approach with two different methods. With the conventional method, only the ultrasound machine placed at the side of the head of the patient across the targeted forearm was utilized. With the tablet method, the ultrasound images were displayed on an iPad Mini positioned on the arm in alignment with the operator's eye axis and needle puncture direction. The success rate and time required for catheterization were compared between the two methods. Success rate was significantly higher (100 vs. 70 %, P = 0.02) and catheterization time significantly shorter (28.5 ± 7.5 vs. 68.2 ± 14.3 s, P method as compared to the conventional method. An ergonomic straight arrangement of the image display is crucial for successful and quick completion of ultrasound-guided arterial catheterization. The present remote display system is a practical method for providing such an arrangement.

  7. A novel fluoride anion modified gelatin nanogel system for ultrasound-triggered drug release.

    Science.gov (United States)

    Wu, Daocheng; Wan, Mingxi

    2008-01-01

    Controlled drug release, especially tumor-targeted drug release, remains a great challenge. Here, we prepare a novel fluoride anion-modified gelatin nanogel system and investigate its characteristics of ultrasound-triggered drug release. Adriamycin gelatin nanogel modified with fluoride anion (ADM-GNMF) was prepared by a modified co-precipitation method with fluoride anion and sodium sulfate. The loading and encapsulation efficiency of the anti-neoplastic agent adriamycin (ADM) were measured by high performance liquid chromatography (HPLC). The size and shape of ADM-GNMF were determined by electron microscopy and photo-correlation spectroscopy. The size distribution and drug release efficiency of ADM-GNMF, before and after sonication, were measured by two designed measuring devices that consisted of either a submicron particle size analyzer and an ultrasound generator as well as an ultrasound generator, automatic sampler, and HPLC. The ADM-GNMF was stable in solution with an average diameter of 46+/-12 nm; the encapsulation and loading efficiency of adriamycin were 87.2% and 6.38%, respectively. The ultrasound-triggered drug release and size change were most efficient at a frequency of 20 kHz, power density of 0.4w/cm2, and a 1~2 min duration. Under this ultrasound-triggered condition, 51.5% of drug in ADM-GNMF was released within 1~2 min, while the size of ADM-GNMF changed from 46 +/- 12 nm to 1212 +/- 35 nm within 1~2 min of sonication and restored to its previous size in 2~3 min after the ultrasound stopped. In contrast, 8.2% of drug in ADM-GNMF was released within 2~3 min without sonication, and only negligible size changes were found. The ADM-GNMF system efficiently released the encompassed drug in response to ultrasound, offering a novel and promising controlled drug release system for targeted therapy for cancer or other diseases.

  8. Complete Resection of Ampullary Paragangliomas Confined to the Submucosa on Endoscopic Ultrasound May Be Best Achieved by Radical Surgical Resection

    Directory of Open Access Journals (Sweden)

    Kevin A. Ghassemi

    2009-06-01

    Full Text Available Paragangliomas of the gastrointestinal tract generally are benign tumors usually found in the second portion of the duodenum. We present a case of paraganglioma of the ampulla of Vater confined to the submucosa on endoscopic ultrasound examination. This was initially treated by endoscopic resection, followed by pancreaticoduodenectomy after local resection margins were positive. Histopathology showed a well-differentiated ampullary paraganglioma confined to the submucosa, but with involvement of one regional lymph node. Only 25 prior cases of paraganglioma at the ampulla of Vater have been reported, and nine of these have demonstrated local or distant metastases. Because of their malignant potential, ampullary paragangliomas should be treated with radical resection if the goal is to achieve complete resection, even if preoperative imaging shows local confinement.

  9. Clinical trials and evaluation of a mobile, robotic tele-ultrasound system.

    Science.gov (United States)

    Courreges, Fabien; Vieyres, Pierre; Istepanian, Robert S H; Arbeille, Philippe; Bru, Conxita

    2005-01-01

    We have developed a robotic tele-ultrasound system (OTELO) that allows an expert to examine a distant patient by ultrasound. At the expert station, a sonographer controls a virtual probe. Movements are reproduced at the patient station, which may be several kilometres away, on a real probe held by a lightweight robot, which is positioned on the patient by a paramedic. Two medical teams tested the tele-ultrasound system at two different hospitals on a total of 52 patients. Except for some difficulties caused by particular conditions, the diagnosis obtained with the remote scanning system agreed in at least 80% of the cases with the diagnosis made by conventional scanning. The results demonstrate the feasibility and efficiency of the device.

  10. First clinical experience with a dedicated MRI-guided high-intensity focused ultrasound system for breast cancer ablation

    Energy Technology Data Exchange (ETDEWEB)

    Merckel, Laura G.; Knuttel, Floor M.; Peters, Nicky H.G.M.; Mali, Willem P.T.M.; Bosch, Maurice A.A.J. van den [University Medical Center Utrecht, Department of Radiology, HP E 01.132, Utrecht (Netherlands); Deckers, Roel; Moonen, Chrit T.W.; Bartels, Lambertus W. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Dalen, Thijs van [Diakonessenhuis Utrecht, Department of Surgery, Utrecht (Netherlands); Schubert, Gerald [Philips Healthcare, Best (Netherlands); Weits, Teun [Diakonessenhuis Utrecht, Department of Radiology, Utrecht (Netherlands); Diest, Paul J. van [University Medical Center Utrecht, Department of Pathology, Utrecht (Netherlands); Vaessen, Paul H.H.B. [University Medical Center Utrecht, Department of Anesthesiology, Utrecht (Netherlands); Gorp, Joost M.H.H. van [Diakonessenhuis Utrecht, Department of Pathology, Utrecht (Netherlands)

    2016-11-15

    To assess the safety and feasibility of MRI-guided high-intensity focused ultrasound (MR-HIFU) ablation in breast cancer patients using a dedicated breast platform. Patients with early-stage invasive breast cancer underwent partial tumour ablation prior to surgical resection. MR-HIFU ablation was performed using proton resonance frequency shift MR thermometry and an MR-HIFU system specifically designed for breast tumour ablation. The presence and extent of tumour necrosis was assessed by histopathological analysis of the surgical specimen. Pearson correlation coefficients were calculated to assess the relationship between sonication parameters, temperature increase and size of tumour necrosis at histopathology. Ten female patients underwent MR-HIFU treatment. No skin redness or burns were observed in any of the patients. No correlation was found between the applied energy and the temperature increase. In six patients, tumour necrosis was observed with a maximum diameter of 3-11 mm. In these patients, the number of targeted locations was equal to the number of areas with tumour necrosis. A good correlation was found between the applied energy and the size of tumour necrosis at histopathology (Pearson = 0.76, p = 0.002). Our results show that MR-HIFU ablation with the dedicated breast system is safe and results in histopathologically proven tumour necrosis. (orig.)

  11. Surgical guidance system using hand-held probe with accompanying positron coincidence detector

    Energy Technology Data Exchange (ETDEWEB)

    Majewski, Stanislaw; Weisenberger, Andrew G.

    2017-10-10

    A surgical guidance system offering different levels of imaging capability while maintaining the same hand-held convenient small size of light-weight intra-operative probes. The surgical guidance system includes a second detector, typically an imager, located behind the area of surgical interest to form a coincidence guidance system with the hand-held probe. This approach is focused on the detection of positron emitting biomarkers with gamma rays accompanying positron emissions from the radiolabeled nuclei.

  12. Measuring Bubble, Drop and Particle Sizes in Multiphase Systems with Ultrasound

    NARCIS (Netherlands)

    Cents, A.H.G.; Brilman, D.W.F.; Versteeg, G.F.; Wijnstra, P.J.; Regtien, P.P.L.

    2004-01-01

    A technique is developed for measurement of bubble, droplet and particle-size distributions in multiphase systems, based on the propagation speed and attenuation of ultrasound. The measurement of the size distribution of the dispersed phase in multiphase systems was desired to analyze the mass-trans

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... specific content. Related Articles and Media Sonohysterography Ultrasound - Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and ...

  14. A system for investigation of biological effects of diagnostic ultrasound on development of zebrafish embryos.

    Science.gov (United States)

    Miller, Douglas L; Zhou, Weibin

    2013-12-01

    A system for scanning zebrafish embryos with diagnostic ultrasound was developed for research into possible biological effects during development. Two troughs for holding embryos were formed from agarose in a rectangular dish and separated by an ultrasound absorber. A 4.9 MHz linear array ultrasound probe was positioned to uniformly scan all the embryos at the bottom of one trough, with the other used for controls. Zebrafish embryos were scanned continuously from 10-24 h post fertilization (hpf) during the segmentation period and gross morphological parameters were measured at 30 hpf, including viability, length, number of visible axons, and the progression of the lateral line primordium (LLP). Our initial tests were encumbered by the thermal effects of probe self-heating, which resulted in accelerated development of the zebrafish embryos. After subsequent optimization, our test revealed a significant retardation of primary motor axons and the migration of the LLP in embryos scanned with ultrasound, which indicated a potential for nonthermal effects on neuronal development. This diagnostic ultrasound exposure system is suitable for further investigation of possible subtle bioeffects, such as perturbation of neuronal migration.

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of urinary and reproductive system disorders in both sexes without x-ray exposure. Risks For standard diagnostic ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  16. In vivo visualization of robotically implemented synthetic tracked aperture ultrasound (STRATUS) imaging system using curvilinear array

    Science.gov (United States)

    Zhang, Haichong K.; Aalamifar, Fereshteh; Boctor, Emad M.

    2016-04-01

    Synthetic aperture for ultrasound is a technique utilizing a wide aperture in both transmit and receive to enhance the ultrasound image quality. The limitation of synthetic aperture is the maximum available aperture size limit determined by the physical size of ultrasound probe. We propose Synthetic-Tracked Aperture Ultrasound (STRATUS) imaging system to overcome the limitation by extending the beamforming aperture size through ultrasound probe tracking. With a setup involving a robotic arm, the ultrasound probe is moved using the robotic arm, while the positions on a scanning trajectory are tracked in real-time. Data from each pose are synthesized to construct a high resolution image. In previous studies, we have demonstrated the feasibility through phantom experiments. However, various additional factors such as real-time data collection or motion artifacts should be taken into account when the in vivo target becomes the subject. In this work, we build a robot-based STRATUS imaging system with continuous data collection capability considering the practical implementation. A curvilinear array is used instead of a linear array to benefit from its wider capture angle. We scanned human forearms under two scenarios: one submerged the arm in the water tank under 10 cm depth, and the other directly scanned the arm from the surface. The image contrast improved 5.51 dB, and 9.96 dB for the underwater scan and the direct scan, respectively. The result indicates the practical feasibility of STRATUS imaging system, and the technique can be potentially applied to the wide range of human body.

  17. Making surgical missions a joint operation: NGO experiences of visiting surgical teams and the formal health care system in Guatemala.

    Science.gov (United States)

    Roche, Stephanie; Hall-Clifford, Rachel

    2015-01-01

    Each year, thousands of Guatemalans receive non-emergent surgical care from short-term medical missions (STMMs) hosted by local non-governmental organizations (NGOs) and staffed by foreign visiting medical teams (VMTs). The purpose of this study was to explore the perspectives of individuals based in NGOs involved in the coordination of surgical missions to better understand how these missions articulate with the larger Guatemalan health care system. During the summers of 2011 and 2013, in-depth interviews were conducted with 25 representatives from 11 different Guatemalan NGOs with experience with surgical missions. Transcripts were analysed for major themes using an inductive qualitative data analysis process. NGOs made use of the formal health care system but were limited by several factors, including cost, issues of trust and current ministry of health policy. Participants viewed the government health care system as a potential resource and expressed a desire for more collaboration. The current practices of STMMs are not conducive to health system strengthening. The role of STMMs must be defined and widely understood by all stakeholders in order to improve patient safety and effectively utilise health resources. Priority should be placed on aligning the work of VMTs with that of the larger health care system.

  18. Multi-processor system for real-time flow estimation in medical ultrasound imaging

    DEFF Research Database (Denmark)

    Stetson, Paul F.; Jensen, Jesper Lomborg; Antonius, Peter

    1997-01-01

    Advanced algorithms for performing signal and image processing on medical ultrasound signals often use the RF ultrasound signal and perform parallel adaptive signal processing. One example is ultrasonic flow estimation with the recursive least-squares lattice filter. Real-time processing...... a client-server model: the server manages semaphores to avoid memory conflicts and handles a queue of tasks and parameter addresses for scheduling the four DSP’s on the board.As an example, we show how to use the system to perform two parallel processes: imaging and flow estimation....

  19. All-optical photoacoustic imaging system using fiber ultrasound probe and hollow optical fiber bundle.

    Science.gov (United States)

    Miida, Yusuke; Matsuura, Yuji

    2013-09-23

    An all-optical 3D photoacoustic imaging probe that consists of an optical fiber probe for ultrasound detection and a bundle of hollow optical fibers for excitation of photoacoustic waves was developed. The fiber probe for ultrasound is based on a single-mode optical fiber with a thin polymer film attached to the output end surface that works as a Fabry Perot etalon. The input end of the hollow fiber bundle is aligned so that each fiber in the bundle is sequentially excited. A thin and flexible probe can be obtained because the probe system does not have a scanning mechanism at the distal end.

  20. Cancer Immunotherapy Utilized Bubble Liposomes and Ultrasound as Antigen Delivery System

    Science.gov (United States)

    Oda, Yusuke; Otake, Shota; Suzuki, Ryo; Otake, Shota; Nishiie, Norihito; Hirata, Keiichi; Taira, Yuichiro; Utoguchi, Naoki; Maruyama, Kazuo

    2010-03-01

    In dendritic cells (DCs)-based cancer immunotherapy, it is important to present the epitope peptide derived from tumor associated antigens (TAAs) on MHC class I in order to induce tumor specific cytotoxic T lymphocytes (CTLs). However, MHC class I molecules generally present the epitope peptides derived from endogenous antigens for DCs but not exogenous ones such as TAAs. Recently, we developed the novel liposomal bubbles (Bubble liposomes) encapsulating perfluoropropane nanobubbles. In this study, we attempted to establish the novel antigen delivery system to induce MHC class I presentation using the combination of ultrasound and Bubble liposomes. Using ovalbumin (OVA) as model antigen, the combination of Bubble liposomes and ultrasound exposure for the DC could induce MHC class I presentation. In addition, the viability of DCs was more than 80%. These results suggest that Bubble liposomes might be a novel ultrasound enhanced antigen delivery tool in DC-based cancer immunotherapy.

  1. Carotid arterial blood pressure waveform monitoring using a portable ultrasound system.

    Science.gov (United States)

    Joohyun Seo; Pietrangelo, Sabino J; Hae-Seung Lee; Sodini, Charles G

    2015-08-01

    This work presents a non-invasive arterial blood pressure (ABP) waveform monitoring technique using ultrasound. A portable ultrasound system to excite ultrasound transducers and acquire data is designed with off-the-shelf components. The insonation angles are identified using a vector Doppler technique based on the cosine dependency of the Doppler signals. The pulse pressure of an estimated waveform at the left common carotid artery is compared to the standard sphygmomanometer measurement in a clinical test. The estimated carotid ABP waveform shows excellent agreement to the finger ABP waveform with expected discrepancy of the systolic peak shape due to different measurement sites. The proposed method also tracks slow blood pressure fluctuations. This validation on human subjects shows potential for a noninvasive blood pressure waveform monitoring device at central arterial sites.

  2. Quantitative assessment of photoacoustic tomography systems integrating clinical ultrasound transducers using novel tissue-simulating phantoms

    Science.gov (United States)

    Vogt, William C.; Jia, Congxian; Wear, Keith A.; Garra, Brian S.; Pfefer, Joshua

    2015-03-01

    Photoacoustic Tomography (PAT) systems based on commercial ultrasound instruments have the benefit of dualmodality imaging, which increases their appeal from a clinical standpoint. However, factors that influence PAT system performance have not been thoroughly investigated and standardized test methods have not been established for image quality evaluation. To address these issues we have adapted phantom-based approaches from ultrasound imaging standards and implemented them to assess a PAT system developed for vascular imaging. Our system comprises a tunable near-infrared pulsed laser and a commercial ultrasound imaging system, including four interchangeable linear array clinical ultrasound transducers with varying center frequencies, acoustic bandwidths and geometries. Phantoms consisted of a customized polyvinyl chloride (PVC) plastisol gel that simulates both optical and acoustic properties of breast tissue. One phantom incorporates a sub-resolution filament array suitable for bimodal ultrasound-photoacoustic imaging, while another contains an array of hemoglobin-filled cylindrical inclusions at various depths. Key performance characteristics were evaluated, including spatial resolution, signal uniformity, contrast, and penetration depth. These characteristics were evaluated at 750 nm at radiant exposures below ANSI safety limits. Effects of transducer properties on imaging performance were evaluated. Axial and lateral resolution ranged from 0.27-0.83 mm and 0.28-1.8 mm, respectively, and penetration depths from 1.9-4.2 cm were achieved. These results demonstrate variation in PAT system performance based on clinical transducer selection, as well as the utility of realistic phantom-based test methods in performing benchtop evaluations of system performance.

  3. Peritendinous calcinosis of calcaneus tendon associated with dermatomyositis: correlation between conventional radiograph, ultrasound, magnetic resonance imaging and gross surgical pathology; Calcinose peritendinea do tendao calcaneo associada a dermatomiosite: correlacao entre radiografia convencional, ultra-sonografia, ressonancia magnetica e macroscopia cirurgica

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, Ana Claudia Ferreira; Gomide, Lidyane Marques de Paula; Lemes, Marcella Stival [Universidade Federal de Goias (UFG), Goiana, GO (Brazil). Faculdade de Medicina. Hospital das Clinicas; Costa, Edegmar Nunes; Rocha, Valney Luiz da [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Faculdade de Medicina. Dept. de Ortopedia; Machado, Marcio Martins; Santos Junior, Rubens Carneiro dos; Barros, Nestor de; Cerri, Giovanni Guido [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Faculdade de Medicina. Dept. de Radiologia; Sernik, Renato Antonio [Sao Paulo Univ., SP (Brazil). Hospital das Clinicas. Inst. de Radiologia; Nunes, Rodrigo Alvarenga [Universidade do Vale do Sapucai (UNIVAS), Pouso Alegre, MG (Brazil). Faculdade de Ciencias Medicas; Albieri, Alexandre Daher [Hospital de Acidentados de Goiania, GO (Brazil)

    2006-01-15

    Interstitial calcinosis is an uncommon condition in which there is either localized or widely disseminated deposition of calcium in the skin, subcutaneous tissues, muscles, and tendons. Calcinosis is often associated with collagen diseases, scleroderma and dermatomyositis. The authors report a case of interstitial calcinosis associated with dermatomyositis studied with conventional radiograph, ultrasound and magnetic resonance imaging, and correlate the imaging findings with the results of surgical pathology gross examination. (author)

  4. Verification and compensation of respiratory motion using an ultrasound imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Chuang, Ho-Chiao, E-mail: hchuang@mail.ntut.edu.tw; Hsu, Hsiao-Yu; Chiu, Wei-Hung; Tien, Der-Chi [Department of Mechanical Engineering, National Taipei University of Technology, Number 1, Section 3, Chung-Hsiao E. Road, Taipei 10608, Taiwan (China); Wu, Ren-Hong; Hsu, Chung-Hsien [Shin Kong Wu Ho-Su Memorial Hospital, Number 95, Wen-Chang Road, Shih-Lin District, Taipei 11101, Taiwan (China)

    2015-03-15

    Purpose: The purpose of this study was to determine if it is feasible to use ultrasound imaging as an aid for moving the treatment couch during diagnosis and treatment procedures associated with radiation therapy, in order to offset organ displacement caused by respiratory motion. A noninvasive ultrasound system was used to replace the C-arm device during diagnosis and treatment with the aims of reducing the x-ray radiation dose on the human body while simultaneously being able to monitor organ displacements. Methods: This study used a proposed respiratory compensating system combined with an ultrasound imaging system to monitor the compensation effect of respiratory motion. The accuracy of the compensation effect was verified by fluoroscopy, which means that fluoroscopy could be replaced so as to reduce unnecessary radiation dose on patients. A respiratory simulation system was used to simulate the respiratory motion of the human abdomen and a strain gauge (respiratory signal acquisition device) was used to capture the simulated respiratory signals. The target displacements could be detected by an ultrasound probe and used as a reference for adjusting the gain value of the respiratory signal used by the respiratory compensating system. This ensured that the amplitude of the respiratory compensation signal was a faithful representation of the target displacement. Results: The results show that performing respiratory compensation with the assistance of the ultrasound images reduced the compensation error of the respiratory compensating system to 0.81–2.92 mm, both for sine-wave input signals with amplitudes of 5, 10, and 15 mm, and human respiratory signals; this represented compensation of the respiratory motion by up to 92.48%. In addition, the respiratory signals of 10 patients were captured in clinical trials, while their diaphragm displacements were observed simultaneously using ultrasound. Using the respiratory compensating system to offset, the diaphragm

  5. A prototype stimulator system for noninvasive Low Intensity Focused Ultrasound delivery.

    Science.gov (United States)

    Mulgaonkar, Amit P; Singh, Rahul S; Babakhanian, Meghedi; Culjat, Martin O; Grundfest, Warren S; Gorgulho, Alessandra; Lacan, Goran; De Salles, Antonio A F; Bystritsky, Alexander; Melega, William P

    2012-01-01

    A prototype Low Intensity Focused Ultrasound (LIFU) stimulator system was developed to evaluate non-invasive neuromodulation in a large animal model. We conducted a feasibility study on a Göttingen minipig, demonstrating reversible, targeted transcranial neuromodulation. The hypothalamus of the minipig was repeatedly stimulated with LIFU which evoked temporally correlated increases in both heart rate and blood pressure.

  6. Performance characterization of an integrated ultrasound, photoacoustic, and thermoacoustic imaging system

    NARCIS (Netherlands)

    Ke, H.; Erpelding, T.; Jankovic, L.; Wang, L.V.

    2012-01-01

    We developed a tri-modality imaging system for breast cancer imagingby integrating photoacoustic (PA) and thermoacoustic (TA) imaging techniques into a modified commercial ultrasound scanner. Laser and microwave excitation pulses were interleaved to enable PA and TA dataacquisition in parallel at th

  7. An Analysis of Pulsed Wave Ultrasound Systems for Blood Velocity Estimation

    DEFF Research Database (Denmark)

    Jensen, J. A.

    1995-01-01

    Pulsed wave ultrasound systems can be used for determining blood's velocity non-invasively in the body. A region of interest is selected, and the received signal is range gated to measure data from the region. One complex sample value is acquired for each pulse emission after complex demodulation...

  8. Noncontact evaluation of articular cartilage degeneration using a novel ultrasound water jet indentation system.

    Science.gov (United States)

    Lu, M-H; Zheng, Y P; Huang, Q-H; Ling, C; Wang, Q; Bridal, L; Qin, L; Mak, A

    2009-01-01

    We previously reported a noncontact ultrasound water jet indentation system for measuring and mapping tissue mechanical properties. The key idea was to utilize a water jet as an indenter as well as the coupling medium for high-frequency ultrasound. In this paper, the system was employed to assess articular cartilage degeneration, using stiffness ratio as an indicator of the mechanical properties of samples. Both the mechanical and acoustical properties of intact and degenerated bovine patellar articular cartilage (n = 8) were obtained in situ. It was found that the stiffness ratio was reduced by 44 +/- 17% after the articular cartilage was treated by 0.25% trypsin at 37 degrees C for 4 h while no significant difference in thickness was observed between the intact and degenerated samples. A significant decrease of 36 +/- 20% in the peak-to-peak amplitude of ultrasound echoes reflected from the cartilage surface was also found for the cartilage samples treated by trypsin. The results also showed that the stiffness obtained with the new method highly correlated with that measured using a standard mechanical testing protocol. A good reproducibility of the measurements was demonstrated. The present results showed that the ultrasound water jet indentation system may provide a potential tool for the non-destructive evaluation of articular cartilage degeneration by simultaneously obtaining mechanical properties, acoustical properties, and thickness data.

  9. Automatic nipple detection on 3D images of an automated breast ultrasound system (ABUS)

    Science.gov (United States)

    Javanshir Moghaddam, Mandana; Tan, Tao; Karssemeijer, Nico; Platel, Bram

    2014-03-01

    Recent studies have demonstrated that applying Automated Breast Ultrasound in addition to mammography in women with dense breasts can lead to additional detection of small, early stage breast cancers which are occult in corresponding mammograms. In this paper, we proposed a fully automatic method for detecting the nipple location in 3D ultrasound breast images acquired from Automated Breast Ultrasound Systems. The nipple location is a valuable landmark to report the position of possible abnormalities in a breast or to guide image registration. To detect the nipple location, all images were normalized. Subsequently, features have been extracted in a multi scale approach and classification experiments were performed using a gentle boost classifier to identify the nipple location. The method was applied on a dataset of 100 patients with 294 different 3D ultrasound views from Siemens and U-systems acquisition systems. Our database is a representative sample of cases obtained in clinical practice by four medical centers. The automatic method could accurately locate the nipple in 90% of AP (Anterior-Posterior) views and in 79% of the other views.

  10. Towards ontology-based decision support systems for complex ultrasound diagnosis in obstetrics and gynecology.

    Science.gov (United States)

    Maurice, P; Dhombres, F; Blondiaux, E; Friszer, S; Guilbaud, L; Lelong, N; Khoshnood, B; Charlet, J; Perrot, N; Jauniaux, E; Jurkovic, D; Jouannic, J-M

    2017-05-01

    We have developed a new knowledge base intelligent system for obstetrics and gynecology ultrasound imaging, based on an ontology and a reference image collection. This study evaluates the new system to support accurate annotations of ultrasound images. We have used the early ultrasound diagnosis of ectopic pregnancies as a model clinical issue. The ectopic pregnancy ontology was derived from medical texts (4260 ultrasound reports of ectopic pregnancy from a specialist center in the UK and 2795 Pubmed abstracts indexed with the MeSH term "Pregnancy, Ectopic") and the reference image collection was built on a selection from 106 publications. We conducted a retrospective analysis of the signs in 35 scans of ectopic pregnancy by six observers using the new system. The resulting ectopic pregnancy ontology consisted of 1395 terms, and 80 images were collected for the reference collection. The observers used the knowledge base intelligent system to provide a total of 1486 sign annotations. The precision, recall and F-measure for the annotations were 0.83, 0.62 and 0.71, respectively. The global proportion of agreement was 40.35% 95% CI [38.64-42.05]. The ontology-based intelligent system provides accurate annotations of ultrasound images and suggests that it may benefit non-expert operators. The precision rate is appropriate for accurate input of a computer-based clinical decision support and could be used to support medical imaging diagnosis of complex conditions in obstetrics and gynecology. Copyright © 2017. Published by Elsevier Masson SAS.

  11. Integration of crawling waves in an ultrasound imaging system. Part 1: system and design considerations.

    Science.gov (United States)

    Hazard, Christopher; Hah, Zaegyoo; Rubens, Deborah; Parker, Kevin

    2012-02-01

    An ultrasound system (GE Logiq 9) was modified to produce a synthetic crawling wave using shear wave displacements generated by the radiation force of focused beams formed at the left and the right edge of the region of interest (ROI). Two types of focusing, normal and axicon, were implemented. Baseband (IQ) data was collected to determine the left and right displacements, which were then used to calculate an interference pattern. By imposing a variable delay between the two pushes, the interference pattern moves across the ROI to produce crawling waves. Also temperature and pressure measurements were made to assess the safety issues. The temperature profiles measured in a veal liver along the focal line showed the maximum temperature rise less than 0.8°C, and the pressure measurements obtained in degassed water and derated by 0.3 dB/cm/MHz demonstrate that the system can operate within FDA safety guidelines.

  12. Evaluation of three-dimensional temperature distributions produced by a low-frequency transcranial focused ultrasound system within ex vivo human skulls.

    Science.gov (United States)

    McDannold, Nathan; Park, Eun-Joo; Mei, Chang-Sheng; Zadicario, Eyal; Jolesz, Ferenc

    2010-09-01

    Transcranial MR-guided focused ultrasound (TcMRgFUS) provides a potential noninvasive alternative to surgical resection and for other treatments for brain disorders. Use of low-frequency ultrasound provides several advantages for TcMRgFUS, but is potentially limited by reflection and standing wave effects that may cause secondary hotspots within the skull cavity. The purpose of this work was to use volumetric magnetic resonance temperature imaging (MRTI) and ex vivo human skulls filled with tissue-mimicking phantom material to search for heating distant from the focal point that may occur during sonication with a TcMRgFUS system as a result of reflections or standing wave effects. Heating during 120-s sonications was monitored within the entire skull volume for 12 different locations in two different skulls. The setup used a hemispheric array operating at 220 kHz. Multiple sonications were delivered at each location while varying the MRTI slice positions to provide full coverage of the skull cavity. An automated routine was used evaluate the MRTI to detect voxel regions that appeared to be heated by ultrasound. No secondary hotspots with a temperature rise of 15% or more of the focal heating were found. The MRTI noise level prevented the identification of possible hotspots with a lower temperature rise. These results suggest that significant secondary heating by this TcMRgFUS system at points distant from the focal point are not common.

  13. Obstetrical Ultrasound

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Obstetric Ultrasound Obstetric ultrasound uses sound waves to produce pictures ... limitations of Obstetrical Ultrasound Imaging? What is Obstetrical Ultrasound Imaging? Ultrasound is safe and painless, and produces ...

  14. Prostate Ultrasound

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves ... the limitations of Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and ...

  15. Ultrasound - Scrotum

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Ultrasound - Scrotum Ultrasound imaging of the scrotum uses sound ... of Ultrasound Imaging of the Scrotum? What is Ultrasound Imaging of the Scrotum? Ultrasound imaging of the ...

  16. Ultrasound -- Vascular

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Ultrasound - Vascular Vascular ultrasound uses sound waves to evaluate ... the limitations of Vascular Ultrasound? What is Vascular Ultrasound? Ultrasound is safe and painless, and produces pictures ...

  17. Hip Ultrasound

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Hip Ultrasound Hip ultrasound uses sound waves to produce pictures ... of Ultrasound Imaging of the Hip? What is Ultrasound Imaging of the Hip? Ultrasound images of the ...

  18. Ultrasound -- Vascular

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound - Vascular Vascular ultrasound uses sound waves to evaluate the ... are the limitations of Vascular Ultrasound? What is Vascular Ultrasound? Ultrasound is safe and painless, and produces ...

  19. The feasibility of an infrared system for real-time visualization and mapping of ultrasound fields

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, Adam; Nunn, John, E-mail: adam.shaw@npl.co.u [National Physical Laboratory, Teddington, Middlesex, TW11 0LW (United Kingdom)

    2010-06-07

    In treatment planning for ultrasound therapy, it is desirable to know the 3D structure of the ultrasound field. However, mapping an ultrasound field in 3D is very slow, with even a single planar raster scan taking typically several hours. Additionally, hydrophones that are used for field mapping are expensive and can be damaged in some therapy fields. So there is value in rapid methods which enable visualization and mapping of the ultrasound field in about 1 min. In this note we explore the feasibility of mapping the intensity distribution by measuring the temperature distribution produced in a thin sheet of absorbing material. A 0.2 mm thick acetate sheet forms a window in the wall of a water tank containing the transducer. The window is oriented at 45{sup 0} to the beam axis, and the distance from the transducer to the window can be varied. The temperature distribution is measured with an infrared camera; thermal images of the inclined plane could be viewed in real time or images could be captured for later analysis and 3D field reconstruction. We conclude that infrared thermography can be used to gain qualitative information about ultrasound fields. Thermal images are easily visualized with good spatial and thermal resolutions (0.044 mm and 0.05 {sup 0}C in our system). The focus and field structure such as side lobes can be identified in real time from the direct video output. 3D maps and image planes at arbitrary orientations to the beam axis can be obtained and reconstructed within a few minutes. In this note we are primarily interested in the technique for characterization of high intensity focused ultrasound (HIFU) fields, but other applications such as physiotherapy fields are also possible. (note)

  20. An FPGA-based ultrasound imaging system using capacitive micromachined ultrasonic transducers.

    Science.gov (United States)

    Wong, Lawrence L P; Chen, Albert I; Logan, Andrew S; Yeow, John T W

    2012-07-01

    We report the design and experimental results of a field-programmable gate array (FPGA)-based real-time ultrasound imaging system that uses a 16-element phased-array capacitive micromachined ultrasonic transducer fabricated using a fusion bonding process. The imaging system consists of the transducer, discrete analog components situated on a custom-made circuit board, the FPGA, and a monitor. The FPGA program consists of five functional blocks: a main counter, transmit and receive beamformer, receive signal pre-processing, envelope detection, and display. No dedicated digital signal processor or personal computer is required for the imaging system. An experiment is carried out to obtain the sector B-scan of a 4-wire target. The ultrasound imaging system demonstrates the possibility of an integrated system-in-a-package solution.

  1. A phantom pig abdomen as an alternative for testing robotic surgical systems: our experience.

    Science.gov (United States)

    Ristolainen, Asko; Colucci, Gianluca; Kruusmaa, Maarja

    2013-11-01

    The use of animals for testing and validating new medical devices and surgical techniques has raised ethical issues for a long time. Following the introduction of the Three Rs principle, significant efforts have been made to achieve a reduction in the numbers of animals used in testing. Nevertheless, the number of large animals used for testing purposes is still too high. This article describes a potential alternative to the use of large animals in the early phase of the development of surgical equipment -- a high-definition phantom pig abdomen. The phantom pig abdomen was developed from computed tomography scans by using affordable materials, and it was used with two different robotic platforms. It permitted the testing of minimally-invasive robotic pancreatic enucleation, with or without intraoperative ultrasound guidance. The phantom pig abdomen has proven to be a realistic tool, with the potential to reduce the cost and time-frame of the experiments. 2013 FRAME.

  2. Detection of neck recurrence in patients with differentiated thyroid cancer: comparison of ultrasound, contrast-enhanced CT and {sup 18}F-FDG PET/CT using surgical pathology as a reference standard: (ultrasound vs. CT vs. {sup 18}F-FDG PET/CT in recurrent thyroid cancer)

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Lan; Yoon, Dae Young; Ku, You Jin [Hallym University College of Medicine, Department of Radiology, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of); Baek, Sora [Hallym University College of Medicine, Department of Nuclear Medicine, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of); Rho, Young-Soo; Chung, Eun-Jae [Hallym University College of Medicine, Department of Otorhinolaryngology, Ilsong Memorial Institute of Head and Neck Cancer, Kangdong Seong-Sim Hospital, Seoul (Korea, Republic of); Koh, Sung Hye [Hallym University Sacred Heart Hospital, Department of Radiology, Hallym University College of Medicine, Anyang, Gyonggi-do (Korea, Republic of)

    2012-10-15

    To compare the diagnostic performance of ultrasound, contrast-enhanced computed tomography (CT) and {sup 18}F-FDG positron emission tomography (PET)/CT for detecting recurrent differentiated thyroid cancer in the neck. Twenty patients who had undergone previous surgery for differentiated thyroid cancer (19 papillary carcinomas; 1 medullary carcinoma) and presented with pathologically proven recurrence in the neck were included. All patients had undergone ultrasound, CT and PET/CT in the 2 months before further surgery. In each patient, ultrasound, CT and PET/CT images were retrospectively reviewed to determine the presence of loco-regional recurrence by level-by-level analysis. Imaging results were correlated with the histological evaluation of the neck dissection as a standard of reference. Recurrences were found at 52 out of 110 cervical nodal levels surgically explored. The sensitivity, specificity and accuracy were 69.2 %, 89.7 % and 80.0 % for ultrasound; 63.5 %, 94.8 % and 80.0 % for CT; and 53.8 %, 79.3 % and 67.3 % for PET/CT, respectively. ROC analysis revealed higher diagnostic performance with ultrasound than with PET/CT for detecting recurrent tumour. Although no significant difference was found among the three techniques, the sensitivity and specificity of ultrasound and CT were higher than those of PET/CT for the evaluation of cervical recurrence in patients with differentiated thyroid cancer. circle Ultrasound, CT and {sup 18} F-FDG PET/CT can all detect recurrent thyroid cancer. circle Ultrasound and CT have higher sensitivity and specificity. (orig.)

  3. Robotic Surgical System for Radical Prostatectomy: A Health Technology Assessment

    Science.gov (United States)

    Wang, Myra; Xie, Xuanqian; Wells, David; Higgins, Caroline

    2017-01-01

    Background Prostate cancer is the second most common type of cancer in Canadian men. Radical prostatectomy is one of the treatment options available, and involves removing the prostate gland and surrounding tissues. In recent years, surgeons have begun to use robot-assisted radical prostatectomy more frequently. We aimed to determine the clinical benefits and harms of the robotic surgical system for radical prostatectomy (robot-assisted radical prostatectomy) compared with the open and laparoscopic surgical methods. We also assessed the cost-effectiveness of robot-assisted versus open radical prostatectomy in patients with clinically localized prostate cancer in Ontario. Methods We performed a literature search and included prospective comparative studies that examined robot-assisted versus open or laparoscopic radical prostatectomy for prostate cancer. The outcomes of interest were perioperative, functional, and oncological. The quality of the body of evidence was examined according to the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) Working Group criteria. We also conducted a cost–utility analysis with a 1-year time horizon. The potential long-term benefits of robot-assisted radical prostatectomy for functional and oncological outcomes were also evaluated in a 10-year Markov model in scenario analyses. In addition, we conducted a budget impact analysis to estimate the additional costs to the provincial budget if the adoption of robot-assisted radical prostatectomy were to increase in the next 5 years. A needs assessment determined that the published literature on patient perspectives was relatively well developed, and that direct patient engagement would add relatively little new information. Results Compared with the open approach, we found robot-assisted radical prostatectomy reduced length of stay and blood loss (moderate quality evidence) but had no difference or inconclusive results for functional and oncological outcomes

  4. MRI-compatible ultrasound heating system with ring-shaped phased arrays for breast tumor thermal therapy.

    Science.gov (United States)

    Chen, Hung-Nien; Chen, Guan-Ming; Lin, Bo-Sian; Lien, Pi-Hsien; Chen, Yung-Yaw; Chen, Gin-Shin; Lin, Win-Li

    2013-01-01

    Therapeutic ultrasound transducers can carry out precise and efficient power deposition for tumor thermal therapy under the guidance of magnetic resonance imaging. For a better heating, organ-specific ultrasound transducers with precision location control system should be developed for tumors located at various organs. It is feasible to perform a better heating for breast tumor thermal therapy with a ring-shaped ultrasound phased-array transducer. In this study, we developed ring-shaped phased-array ultrasound transducers with 1.0 and 2.5 MHz and a precision location control system to drive the transducers to the desired location to sonicate the designated region. Both thermo-sensitive hydrogel phantom and ex vivo fresh pork were used to evaluate the heating performance of the transducers. The results showed that the ring-shaped phased array ultrasound transducers were very promising for breast tumor heating with the variation of heating patterns and without overheating the ribs.

  5. Design, Implementation and Testing of Master Slave Robotic Surgical System

    OpenAIRE

    Syed Amjad Ali; Amir Mahmood Soomro; Arbab Nighat Khizer

    2015-01-01

    The autonomous manipulation of the medical robotics is needed to draw up a complete surgical plan in development. The autonomy of the robot comes from the fact that once the plan is drawn up off-line, it is the servo loops, and only these, that control the actions of the robot online, based on instantaneous control signals and measurements provided by the vision or force sensors. Using only these autonomous techniques in medical and surgical robotics remain relatively limited for two main rea...

  6. Orthognathic positioning system: intraoperative system to transfer virtual surgical plan to operating field during orthognathic surgery.

    Science.gov (United States)

    Polley, John W; Figueroa, Alvaro A

    2013-05-01

    To introduce the concept and use of an occlusal-based "orthognathic positioning system" (OPS) to be used during orthognathic surgery. The OPS consists of intraoperative occlusal-based devices that transfer virtual surgical planning to the operating field for repositioning of the osteotomized dentoskeletal segments. The system uses detachable guides connected to an occlusal splint. An initial drilling guide is used to establish stable references or landmarks. These are drilled on the bone that will not be repositioned adjacent to the osteotomy line. After mobilization of the skeletal segment, a final positioning guide, referenced to the drilled landmarks, is used to transfer the skeletal segment according to the virtual surgical planning. The OPS is digitally designed using 3-dimensional computer-aided design/computer-aided manufacturing technology and manufactured with stereolithographic techniques. Virtual surgical planning has improved the preoperative assessment and, in conjunction with the OPS, the execution of orthognathic surgery. The OPS has the possibility to eliminate the inaccuracies commonly associated with traditional orthognathic surgery planning and to simplify the execution by eliminating surgical steps such as intraoperative measuring, determining the condylar position, the use of bulky intermediate splints, and the use of intermaxillary wire fixation. The OPS attempts precise translation of the virtual plan to the operating field, bridging the gap between virtual and actual surgery. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Computer-enhanced thoracoscopic thymectomy with the Zeus telemanipulation surgical system.

    Science.gov (United States)

    Berman, Marius; Stamler, Alon; Vidne, Bernardo A; Saute, Milton

    2003-09-01

    Recent years have witnessed important progress in the use of minimally invasive robotic-enhanced surgical systems in cardiac and general thoracic interventions. We report the first-ever successful use of the Zeus robotic surgical system (Computer Motion, Inc, Goleta, CA) for the excision of an anterior mediastinal mass. Proper positioning of the thoracic ports for the robotic arms to permit a wide range of movement, is the key to the application of the system for intrathoracic cage operations. Other advantages of the system include three-dimensional voice controlled imaging, low-heat surgical field, and good exposure of the structures.

  8. Contrast-enhanced ultrasound improved performance of breast imaging reporting and data system evaluation of critical breast lesions

    Institute of Scientific and Technical Information of China (English)

    Jun Luo; Ji-Dong Chen; Qing Chen; Lin-Xian Yue; Guo Zhou; Cheng Lan; Yi Li; Chi-Hua Wu; Jing-Qiao Lu

    2016-01-01

    AIM: To determine whether contrast-enhanced ultrasound(CEUS) can improve the precision of breast imaging reporting and data system(BI-RADS) categorization. METHODS: A total of 230 patients with 235 solid breast lesions classified as BI-RADS 4 on conventional ultrasound were evaluated. CEUS was performed within one week before core needle biopsy or surgical resection and a revised BI-RADS classification was assigned based on 10 CEUS imaging characteristics. Receiver operating characteristic curve analysis was then conducted to evaluate the diagnostic performance of CEUS-based BI-RADS assignment with pathological examination as reference criteria. RESULTS: The CEUS-based BI-RADS evaluation classified 116/235(49.36%) lesions into category 3, 20(8.51%), 13(5.53%) and 12(5.11%) lesions into categories 4A, 4B and 4C, respectively, and 74(31.49%) into category 5. Selecting CEUS-based BI-RADS category 4A as an appropriate cut-off gave sensitivity and specificity values of 85.4% and 87.8%, respectively, for the diagnosisof malignant disease. The cancer-to-biopsy yield was 73.11% with CEUS-based BI-RADS 4A selected as the biopsy threshold compared with 40.85% otherwise, while the biopsy rate was only 42.13% compared with 100% otherwise. Overall, only 4.68% of invasive cancers were misdiagnosed.CONCLUSION: This pilot study suggests that evaluation of BI-RADS 4 breast lesions with CEUS results in reduced biopsy rates and increased cancer-to-biopsy yields.

  9. Utilization of ultrasound sensors for anti-collision systems of powered wheelchairs.

    Science.gov (United States)

    Dutta, Tilak; Fernie, Geoff R

    2005-03-01

    Anti-collision systems have been developed for use with powered wheelchairs in order to enable people with cognitive or physical impairments to safely operate a powered wheelchair. Anti-collision systems consist of sensors that have the ability to detect objects near the wheelchair and a computer that can stop the chair if a collision is determined to be likely. This investigation considered the suitability of using ultrasound sensors in such a system when encountering objects typically found within a home or a long-term care facility. An ultrasound sensor's ability to detect an object was dependent on the object's size, shape, specularity, reflectivity, and sound absorption characteristics. Ultrasound sensors, by themselves, were found to be unsuitable for anti-collision systems due to an inability to detect objects commonly encountered in the target environment (the home or long-term care facility) without increasing the complexity of the system to such a degree that it would be prohibitive to deploy this technology to the public.

  10. Experimental system for perfusion imaging and time-intensity processing based on ultrasound contrast agent

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Objective: To present a self-developed experimental system for basic studies of blood perfusion imaging and time-intensity evaluating based on ultrasound contrast agent. Methods: The experimental system performed the image reconstruction and time-intensity processing with radio frequency signals. The system was comprised of ultra-high speed hardware data acquisition interface and low computational cost algorithms. The self-made contrast agent ,blood mimic phantom and capillary phantom model were used to validate the experimental system. Results: The images acquired in blood phantoms with linear-array and curve-array transducers were given. The time-intensity curves corresponding to selected region of interested from image sequence were demonstrated. It was also shown the time-intensity based decay curves and a comparison of decay of ultrasound contrast agent under different ultrasound powers. Conclusion: Several experiments resulted from two in vitro phantom models show that the experimental system can be used to basic studies of blood perfusion and further clinical studies of microvasculature perfusion.

  11. Intraocular robotic interventional surgical system (IRISS): Mechanical design, evaluation, and master-slave manipulation.

    Science.gov (United States)

    Wilson, Jason T; Gerber, Matthew J; Prince, Stephen W; Chen, Cheng-Wei; Schwartz, Steven D; Hubschman, Jean-Pierre; Tsao, Tsu-Chin

    2017-07-31

    Since the advent of robotic-assisted surgery, the value of using robotic systems to assist in surgical procedures has been repeatedly demonstrated. However, existing technologies are unable to perform complete, multi-step procedures from start to finish. Many intraocular surgical steps continue to be manually performed. An intraocular robotic interventional surgical system (IRISS) capable of performing various intraocular surgical procedures was designed, fabricated, and evaluated. Methods were developed to evaluate the performance of the remote centers of motion (RCMs) using a stereo-camera setup and to assess the accuracy and precision of positioning the tool tip using an optical coherence tomography (OCT) system. The IRISS can simultaneously manipulate multiple surgical instruments, change between mounted tools using an onboard tool-change mechanism, and visualize the otherwise invisible RCMs to facilitate alignment of the RCM to the surgical incision. The accuracy of positioning the tool tip was measured to be 0.205±0.003 mm. The IRISS was evaluated by trained surgeons in a remote surgical theatre using post-mortem pig eyes and shown to be effective in completing many key steps in a variety of intraocular surgical procedures as well as being capable of performing an entire cataract extraction from start to finish. The IRISS represents a necessary step towards fully automated intraocular surgery and demonstrated accurate and precise master-slave manipulation for cataract removal and-through visual feedback-retinal vein cannulation. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also called transrectal ultrasound, provides ...

  13. Development and Validation of a Near-Infrared Optical System for Tracking Surgical Instruments.

    Science.gov (United States)

    Lin, Qinyong; Cai, Ken; Yang, Rongqian; Chen, Huazhou; Wang, Zhigang; Zhou, Jing

    2016-04-01

    Surgical navigation systems can help doctors maximize the accuracy of surgeries, minimize operation durations, avoid mistakes, and improve the survival chances of patients. The tracking of device is an important component in surgical navigation systems. However, commercial surgical tracking devices are expensive, thus hindering the development of surgical navigation systems, particularly in developing countries. Therefore, an accurate and low-cost near-infrared optical tracking system is presented in this study for the real-time tracking of surgical tools and for measuring and displaying the positions of these tools relative to lesions and other targets inside a patient's body. A relative algorithm for the registration of surgical tools is also proposed in this paper to yield easy, safe, and precise tracking. Experiments are conducted to test the performance of the system. Results show that the mean square errors of the distances between the light-emitting points on the surgical tools are less than 0.3 mm, with the mean square error of distance between the tip and light-emitting points is less than 0.025 mm and that between two adjacent corner points is 0.2714 mm.

  14. Real-time feedback control for high-intensity focused ultrasound system using localized motion imaging

    Science.gov (United States)

    Sugiyama, Ryusuke; Kanazawa, Kengo; Seki, Mika; Azuma, Takashi; Sasaki, Akira; Takeuchi, Hideki; Fujiwara, Keisuke; Itani, Kazunori; Tamano, Satoshi; Yoshinaka, Kiyoshi; Takagi, Shu; Matsumoto, Yoichiro

    2015-07-01

    High-intensity focused ultrasound (HIFU) is one of the noninvasive treatment for tumors. Visualizing the treated area inside the human body is necessary to control the HIFU exposure. Localized motion imaging (LMI) using ultrasound to induce and detect tissue deformation is one technique to detect a change in tissue stiffness caused by thermal coagulation. In experiments with porcine liver, LMI has shown to detect deformation with less than 20% accuracy. We have developed a prototype feedback control system using real-time LMI. In this system, coagulation size was measured every 1 s and controlled to correspond to a targeted size. The typical size error was reduced to 14% from 35%. LMI displacements in normal and coagulated tissues were sufficiently different to discriminate between coagulated areas and noncoagulated ones after HIFU sonication and to visualize treated areas after HIFU treatment.

  15. A novel image-guided high-intensity focused ultrasound system for tumor treatment

    Science.gov (United States)

    Wu, Zhiqiang; Wu, Puwei; Chen, Bojie; Guan, Jian; Huang, Zheng

    2004-07-01

    A novel ultrasonography-guided high intensity focused ultrasound (HIFU) system (FS-100; Force Electronics Co. Ltd, Chongqing, China) was developed for non-invasive thermal ablation of tumor. The proprietary therapy delivery system is an integration of the digital image progressing, automatic control and the high intensity focused ultrasound thermal ablation devices. The therapeutic ultrasound probe (φ = 240 mm) consists of eight circular HIFU transducers with a curved surface of a diameter of 60 mm. Dual focused beams generated from the probe were used in this system for thermal delivery. The probe has the maximal resonance frequency of 1 MHz, a maximal treatment depth of 160 mm and focal spot diameter of 3 mm. The maximal intensity at the focal spot is 10,000 W/cm2. The imaging and HIFU components are located on top of the device, therefore, the focused ultrasound beams can be delivered to the patient in a supine position. The motion, targeting and localization of the probe are controlled by a PMAC-PC motion controller and an 8-independent-axis mechanical device. The linear motion error of the probe localization is <= 0.1 mm. The ultrasonographic image information is used for treatment planning and therapeutic interventions, such as target definition and registration, visualization of the three-dimensional anatomy of desired target(s), automatic positioning the thermal beams on targets, controlling thermal delivery, and rapid evaluation of target response post-treatment. The preclinical experimental results will be presented. The safety, feasibility and effectiveness of this novel HIFU system will be tested.

  16. [A 3D-ultrasound imaging system based on back-end scanning mode].

    Science.gov (United States)

    Qi, Jian; Chen, Yimin; Ding, Mingyue; Wei, Chiming

    2012-07-01

    A new scanning mode is proposed that the front-end of the probe is fixed, while the back-end makes fan-shaped, scanning movement. The new scanning mode avoided ribs drawbacks successfully. Based on the new scanning mode a 3D-Ultrasound Images System is accomplished to acquire 2D data of fetusfetus fetusfetus phantom and livers and kidneys, to demonstrates the effectiveness of the new scanning mode.

  17. The state of the vegetative nervous system in patients with gonarthrosis for surgical treatment before and after surgical treatment

    Directory of Open Access Journals (Sweden)

    Karaseva T.lu.

    2012-12-01

    Full Text Available Aim. Analyzing the vegetative tensity of organism» functional systems before and after surgical treatment of elderly patients with metabolic-and-dystrophic gonarthrosis. Methods. The evaluation of vegetative homeostasis, reactivity of the vegetative nervous system by the data of variation pulsometry («REAN-POLY» RGPA-6/12, Taganrog in 60 patients with gonarthrosis at the age of 50-72 years and the disease duration — 9+1.5 years before and after surgical treatment: total tunnelization (Group I, tunnelization with osteotomy of leg bones for correction of limb biomechanical axis (Group II, treatment-and-diagnostic arthroscopy (Group III. Results. The reduction of the level of hypoxia tolerance and the decrease of the processes of general adaptation one month after surgery in Group I was registered in 40% of patients. As for patients of Group II, by the end of the period of fixation with the llizarov device — in 50%. As for those of Group III after arthroscopy — in 10% of patients. Among the patients whose 1С / 1С calculated parameter after surgical treatment was registered <1.0, its values were >10.0 before treatment in 70% of cases. At rest, marked vagotonia was registered with hypersympathicotonic reaction to orthotest, as well as with sharp decrease of the proportion of second-order slow waves while transition to standing position (VLF proportion <10.0%, thereby reflecting organism»s energy deficiency state. Conclusion. Preoperative examination. When VLF proportion after orthotest is registered <10.0%, such patients should be referred to risk group and prescribed in-depth examination. The index of centralization (1С dynamics for orthotest (1С test/1С rest is one of the criteria of functional recovery level for the particular patient: its increase points to the positive dynamics of restorative rehabilitative process, and the values <1.0 —to the negative one.

  18. Anatomy and Physiology. Module Set II: Major Body Systems. Teacher Edition [and] Student Edition. Surgical Technology.

    Science.gov (United States)

    Hilley, Robert

    This document, which is the second part of a two-part set of modules on anatomy and physiology for future surgical technicians, contains the teacher and student editions of an introduction to anatomy and physiology that consists of modules on the following body systems: integumentary system; skeletal system; muscular system; nervous system;…

  19. High frame rate photoacoustic imaging at 7000 frames per second using clinical ultrasound system.

    Science.gov (United States)

    Sivasubramanian, Kathyayini; Pramanik, Manojit

    2016-02-01

    Photoacoustic tomography, a hybrid imaging modality combining optical and ultrasound imaging, is gaining attention in the field of medical imaging. Typically, a Q-switched Nd:YAG laser is used to excite the tissue and generate photoacoustic signals. But, such photoacoustic imaging systems are difficult to translate into clinical applications owing to their high cost, bulky size often requiring an optical table to house such lasers. Moreover, the low pulse repetition rate of few tens of hertz prevents them from being used in high frame rate photoacoustic imaging. In this work, we have demonstrated up to 7000 Hz photoacoustic imaging (B-mode) and measured the flow rate of a fast moving object. We used a ~140 nanosecond pulsed laser diode as an excitation source and a clinical ultrasound imaging system to capture and display the photoacoustic images. The excitation laser is ~803 nm in wavelength with ~1.4 mJ energy per pulse. So far, the reported 2-dimensional photoacoustic B-scan imaging is only a few tens of frames per second using a clinical ultrasound system. Therefore, this is the first report on 2-dimensional photoacoustic B-scan imaging with 7000 frames per second. We have demonstrated phantom imaging to view and measure the flow rate of ink solution inside a tube. This fast photoacoustic imaging can be useful for various clinical applications including cardiac related problems, where the blood flow rate is quite high, or other dynamic studies.

  20. Medical Devices; General and Plastic Surgery Devices; Classification of the Magnetic Surgical Instrument System. Final order.

    Science.gov (United States)

    2016-09-21

    The Food and Drug Administration (FDA) is classifying the Magnetic Surgical Instrument System into class II (special controls). The special controls that will apply to the device are identified in this order and will be part of the codified language for the magnetic surgical instrument system's classification. The Agency is classifying the device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of the device.

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces ... of page What are some common uses of the procedure? A transrectal ultrasound of the prostate gland ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... are the limitations of Pelvic Ultrasound Imaging? What is Pelvic Ultrasound Imaging? Ultrasound is safe and painless, ... through the blood vessels. top of page How is the procedure performed? Transabdominal: For most ultrasound exams, ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate gland ... of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or sonography , ...

  4. Ultrasound - Breast

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Ultrasound - Breast Ultrasound imaging of the breast uses sound waves ... the Breast? What is Ultrasound Imaging of the Breast? Ultrasound is safe and painless, and produces pictures ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to produce pictures of the structures and ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces ... of page What are some common uses of the procedure? A transrectal ultrasound of the prostate gland ...

  8. Precision-guided surgical navigation system using laser guidance and 3D autostereoscopic image overlay.

    Science.gov (United States)

    Liao, Hongen; Ishihara, Hirotaka; Tran, Huy Hoang; Masamune, Ken; Sakuma, Ichiro; Dohi, Takeyoshi

    2010-01-01

    This paper describes a precision-guided surgical navigation system for minimally invasive surgery. The system combines a laser guidance technique with a three-dimensional (3D) autostereoscopic image overlay technique. Images of surgical anatomic structures superimposed onto the patient are created by employing an animated imaging method called integral videography (IV), which can display geometrically accurate 3D autostereoscopic images and reproduce motion parallax without the need for special viewing or tracking devices. To improve the placement accuracy of surgical instruments, we integrated an image overlay system with a laser guidance system for alignment of the surgical instrument and better visualization of patient's internal structure. We fabricated a laser guidance device and mounted it on an IV image overlay device. Experimental evaluations showed that the system could guide a linear surgical instrument toward a target with an average error of 2.48 mm and standard deviation of 1.76 mm. Further improvement to the design of the laser guidance device and the patient-image registration procedure of the IV image overlay will make this system practical; its use would increase surgical accuracy and reduce invasiveness.

  9. Development of a Wireless and Near Real-Time 3D Ultrasound Strain Imaging System.

    Science.gov (United States)

    Chen, Zhaohong; Chen, Yongdong; Huang, Qinghua

    2016-04-01

    Ultrasound elastography is an important medical imaging tool for characterization of lesions. In this paper, we present a wireless and near real-time 3D ultrasound strain imaging system. It uses a 3D translating device to control a commercial linear ultrasound transducer to collect pre-compression and post-compression radio-frequency (RF) echo signal frames. The RF frames are wirelessly transferred to a high-performance server via a local area network (LAN). A dynamic programming strain estimation algorithm is implemented with the compute unified device architecture (CUDA) on the graphic processing unit (GPU) in the server to calculate the strain image after receiving a pre-compression RF frame and a post-compression RF frame at the same position. Each strain image is inserted into a strain volume which can be rendered in near real-time. We take full advantage of the translating device to precisely control the probe movement and compression. The GPU-based parallel computing techniques are designed to reduce the computation time. Phantom and in vivo experimental results demonstrate that our system can generate strain volumes with good quality and display an incrementally reconstructed volume image in near real-time.

  10. SARUS: A Synthetic Aperture Real-Time Ultrasound System

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Holten-Lund, Hans; Nilsson, Ronnie Thorup

    2013-01-01

    -resolution images/s. Both RF element data and beamformed data can be stored in the system for later storage and processing. The stored data can be transferred in parallel using the system’s sixty-four 1-Gbit Ethernet interfaces at a theoretical rate of 3.2 GB/s to a 144-core Linux cluster....

  11. Simulation of advanced ultrasound systems using Field II

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2004-01-01

    impulse responses is explained. A simulation example for a synthetic aperture spread spectrum flow systems is described. It is shown how the advanced coded excitation can be set up, and how the simulation can be parallelized to reduce the simulation time from 17 months to 391 hours using a 32 CPU Linux...

  12. Implementation of a Rotational Ultrasound Biomicroscopy System Equipped with a High-Frequency Angled Needle Transducer — Ex Vivo Ultrasound Imaging of Porcine Ocular Posterior Tissues

    Directory of Open Access Journals (Sweden)

    Tae-Hoon Bok

    2014-09-01

    Full Text Available The mechanical scanning of a single element transducer has been mostly utilized for high-frequency ultrasound imaging. However, it requires space for the mechanical motion of the transducer. In this paper, a rotational scanning ultrasound biomicroscopy (UBM system equipped with a high-frequency angled needle transducer is designed and implemented in order to minimize the space required. It was applied to ex vivo ultrasound imaging of porcine posterior ocular tissues through a minimal incision hole of 1 mm in diameter. The retina and sclera for the one eye were visualized in the relative rotating angle range of 270° ~ 330° and at a distance range of 6 ~ 7 mm, whereas the tissues of the other eye were observed in relative angle range of 160° ~ 220° and at a distance range of 7.5 ~ 9 mm. The layer between retina and sclera seemed to be bent because the distance between the transducer tip and the layer was varied while the transducer was rotated. Certin features of the rotation system such as the optimal scanning angle, step angle and data length need to be improved for ensure higher accuracy and precision. Moreover, the focal length should be considered for the image quality. This implementation represents the first report of a rotational scanning UBM system.

  13. Application of Ultrasound in a Closed System: Optimum Condition for Antioxidants Extraction of Blackberry (Rubus fructicosus) Residues

    OpenAIRE

    2016-01-01

    Blackberry processing generates up to 20% of residues composed mainly of peel, seeds and pulp that are abundant in flavonoids. The objective of this study was to optimize the ultrasound conditions, in a closed system, for antioxidants extraction, using the response surface methodology. Blackberry (Rubus fructicosus) residues were analyzed for total phenolics, total anthocyanins, and antioxidant activity by ABTS and DPPH. The selected independent variables were ultrasound amplitude (X1: 80%–90...

  14. 3D temperature field reconstruction using ultrasound sensing system

    Science.gov (United States)

    Liu, Yuqian; Ma, Tong; Cao, Chengyu; Wang, Xingwei

    2016-04-01

    3D temperature field reconstruction is of practical interest to the power, transportation and aviation industries and it also opens up opportunities for real time control or optimization of high temperature fluid or combustion process. In our paper, a new distributed optical fiber sensing system consisting of a series of elements will be used to generate and receive acoustic signals. This system is the first active temperature field sensing system that features the advantages of the optical fiber sensors (distributed sensing capability) and the acoustic sensors (non-contact measurement). Signals along multiple paths will be measured simultaneously enabled by a code division multiple access (CDMA) technique. Then a proposed Gaussian Radial Basis Functions (GRBF)-based approach can approximate the temperature field as a finite summation of space-dependent basis functions and time-dependent coefficients. The travel time of the acoustic signals depends on the temperature of the media. On this basis, the Gaussian functions are integrated along a number of paths which are determined by the number and distribution of sensors. The inversion problem to estimate the unknown parameters of the Gaussian functions can be solved with the measured times-of-flight (ToF) of acoustic waves and the length of propagation paths using the recursive least square method (RLS). The simulation results show an approximation error less than 2% in 2D and 5% in 3D respectively. It demonstrates the availability and efficiency of our proposed 3D temperature field reconstruction mechanism.

  15. A preliminary study of skin ultrasound in diffuse cutaneous systemic sclerosis: Does skin echogenicity matter?

    Science.gov (United States)

    Xu, Dong; Wang, Liang; Li, Jian-chu; Jiang, Yu-xin; Wang, Qian; Li, Meng-tao; Zhang, Feng-chun; Zeng, Xiao-feng

    2017-01-01

    Objective To evaluate the usefulness of skin ultrasound and acoustic radiation force impulse (ARFI) quantification in diffuse cutaneous systemic sclerosis (dcSSc). Patients and methods 28 patients with dcSSc, and 15 age gender matched normal controls were recruited. Skin echogenicity, thickness, and ARFI quantification were measured by ultrasound at 17 sites corresponding to the modified Rodnan skin score (mRSS) in each participant. Compared with controls, skin echogenicity of dcSSc patients was classified into isoechoic, hypoechoic, and hyperechoic. The skin thickness, ARFI quantification and mRSS were compared between isoechoic, hypoechoic, hyperechoic and controls. Results In patients with dcSSc, the skin thickness increased as the echogenicity changed on the order of isoechoic, hypoechoic and hyperechoic. ARFI quantification was significantly higher in hyperechoic than isoechoic (p<0.001). The mRSS were significantly higher in hyperechoic and/or hypoechoic than isoechoic. For isoechoic patients and healthy controls, the skin echogenicity or thickness was no significant different, however, the ARFI quantification was significantly higher in isoechoic than controls. Conclusion Skin ultrasound is feasible for assessing the skin involvement in dcSSc. Skin echogenicity correlates with skin thickness, stiffness, and mRSS. ARFI quantification may be more sensitive to detect skin changes, compared with skin echogenicity and thickness. PMID:28339492

  16. Light-emitting diode-based multiwavelength diffuse optical tomography system guided by ultrasound

    Science.gov (United States)

    Yuan, Guangqian; Alqasemi, Umar; Chen, Aaron; Yang, Yi; Zhu, Quing

    2014-01-01

    Abstract. Laser diodes are widely used in diffuse optical tomography (DOT) systems but are typically expensive and fragile, while light-emitting diodes (LEDs) are cheaper and are also available in the near-infrared (NIR) range with adequate output power for imaging deeply seated targets. In this study, we introduce a new low-cost DOT system using LEDs of four wavelengths in the NIR spectrum as light sources. The LEDs were modulated at 20 kHz to avoid ambient light. The LEDs were distributed on a hand-held probe and a printed circuit board was mounted at the back of the probe to separately provide switching and driving current to each LED. Ten optical fibers were used to couple the reflected light to 10 parallel photomultiplier tube detectors. A commercial ultrasound system provided simultaneous images of target location and size to guide the image reconstruction. A frequency-domain (FD) laser-diode-based system with ultrasound guidance was also used to compare the results obtained from those of the LED-based system. Results of absorbers embedded in intralipid and inhomogeneous tissue phantoms have demonstrated that the LED-based system provides a comparable quantification accuracy of targets to the FD system and has the potential to image deep targets such as breast lesions. PMID:25473884

  17. Toward a reduced-wire readout system for ultrasound imaging.

    Science.gov (United States)

    Lim, Jaemyung; Arkan, Evren F; Degertekin, F Levent; Ghovanloo, Maysam

    2014-01-01

    We present a system-on-a-chip (SoC) for use in high-frequency capacitive micromachined ultrasonic transducer (CMUT) imaging systems. This SoC consists of trans-impedance amplifiers (TIA), delay locked loop (DLL) based clock multiplier, quadrature sampler, and pulse width modulator (PWM). The SoC down converts RF echo signal to baseband by quadrature sampling which facilitates modulation. To send data through a 1.6 m wire in the catheter which has limited bandwidth and is vulnerable to noise, the SoC creates a pseudo-digital PWM signal which can be used for back telemetry or wireless readout of the RF data. In this implementation, using a 0.35-μm std. CMOS process, the TIA and single-to-differential (STD) converter had 45 MHz bandwidth, the quadrature sampler had 10.1 dB conversion gain, and the PWM had 5-bit ENoB. Preliminary results verified front-end functionality, and the power consumption of a TIA, STD, quadrature sampler, PWM, and clock multiplier was 26 mW from a 3 V supply.

  18. Radius surgical system and conventional laparoscopic instruments in abdominal surgery: application, learning curve and ergonomy.

    Science.gov (United States)

    Di Lorenzo, N; Camperchioli, I; Gaspari, A L

    2007-12-01

    We illustrate our experience with a new class of instruments, the mechanical manipulators (MM), whose main features are an improved mobility, and ergonomy and a modular structure. A specific MM, the Radius Surgical System (RADIUS), has been used both for educational purposes as well as in clinical studies, demonstrating that it can represent an efficient tool to support surgeons performing surgical complex procedures, with a short learning curve for the postural attitude.

  19. Early clinical experience with the da Vinci Xi Surgical System in general surgery.

    Science.gov (United States)

    Hagen, Monika E; Jung, Minoa K; Ris, Frederic; Fakhro, Jassim; Buchs, Nicolas C; Buehler, Leo; Morel, Philippe

    2016-12-27

    The da Vinci Xi Surgical System (Intuitive Surgical Inc., Sunnyvale, CA, USA) has been released in 2014 to facilitate minimally invasive surgery. Novel features are targeted towards facilitating complex multi-quadrant procedures, but data is scarce so far. Perioperative data of patients who underwent robotic general surgery with the da Vinci Xi system within the first 6 month after installation were collected and analyzed. The gastric bypass procedures performed with the da Vinci Xi Surgical System were compared to an equal amount of the last procedures with the da Vinci Si Surgical System. Thirty-one foregut (28 Roux-en-Y gastric bypasses), 6 colorectal procedures and 1 revisional biliary procedure were performed. The mean operating room (OR) time was 221.8 (±69.0) minutes for gastric bypasses and 306.5 (±48.8) for colorectal procedures with mean docking time of 9.4 (±3.8) minutes. The gastric bypass procedure was transitioned from a hybrid to a fully robotic approach. In comparison to the last 28 gastric bypass procedures performed with the da Vinci Si Surgical System, the OR time was comparable (226.9 versus 230.6 min, p = 0.8094), but the docking time significantly longer with the da Vinci Xi Surgical System (8.5 versus 6.1 min, p = 0.0415). All colorectal procedures were performed with a single robotic docking. No intraoperative and two postoperative complications occurred. The da Vinci Xi might facilitate single-setups of totally robotic gastric bypass and colorectal surgeries. However, further comparable research is needed to clearly determine the significance of this latest version of the da Vinci Surgical System.

  20. A cyber-physical management system for delivering and monitoring surgical instruments in the OR.

    Science.gov (United States)

    Li, Yu-Ting; Jacob, Mithun; Akingba, George; Wachs, Juan P

    2013-08-01

    The standard practice in the operating room (OR) is having a surgical technician deliver surgical instruments to the surgeon quickly and inexpensively, as required. This human "in the loop" system may result in mistakes (eg, missing information, ambiguity of instructions, and delays). Errors can be reduced or eliminated by integrating information technology (IT) and cybernetics into the OR. Gesture and voice automatic acquisition, processing, and interpretation allow interaction with these new systems without disturbing the normal flow of surgery. This article describes the development of a cyber-physical management system (CPS), including a robotic scrub nurse, to support surgeons by passing surgical instruments during surgery as required and recording counts of surgical instruments into a personal health record (PHR). The robot used responds to hand signals and voice messages detected through sophisticated computer vision and data mining techniques. The CPS was tested during a mock surgery in the OR. The in situ experiment showed that the robot recognized hand gestures reliably (with an accuracy of 97%), it can retrieve instruments as close as 25 mm, and the total delivery time was less than 3 s on average. This online health tool allows the exchange of clinical and surgical information to electronic medical record-based and PHR-based applications among different hospitals, regardless of the style viewer. The CPS has the potential to be adopted in the OR to handle surgical instruments and track them in a safe and accurate manner, releasing the human scrub tech from these tasks.

  1. Processing system of jaws tomograms for pathology identification and surgical guide modeling

    Energy Technology Data Exchange (ETDEWEB)

    Putrik, M. B., E-mail: pmb-88@mail.ru; Ivanov, V. Yu. [Ural Federal University named after the first President of Russia B.N. Yeltsin, Yekaterinburg (Russian Federation); Lavrentyeva, Yu. E. [Private dental clinic «Uraldent», Yekaterinburg (Russian Federation)

    2015-11-17

    The aim of the study is to create an image processing system, which allows dentists to find pathological resorption and to build surgical guide surface automatically. X-rays images of jaws from cone beam tomography or spiral computed tomography are the initial data for processing. One patient’s examination always includes up to 600 images (or tomograms), that’s why the development of processing system for fast automation search of pathologies is necessary. X-rays images can be useful not for only illness diagnostic but for treatment planning too. We have studied the case of dental implantation – for successful surgical manipulations surgical guides are used. We have created a processing system that automatically builds jaw and teeth boundaries on the x-ray image. After this step, obtained teeth boundaries used for surgical guide surface modeling and jaw boundaries limit the area for further pathologies search. Criterion for the presence of pathological resorption zones inside the limited area is based on statistical investigation. After described actions, it is possible to manufacture surgical guide using 3D printer and apply it in surgical operation.

  2. Processing system of jaws tomograms for pathology identification and surgical guide modeling

    Science.gov (United States)

    Putrik, M. B.; Lavrentyeva, Yu. E.; Ivanov, V. Yu.

    2015-11-01

    The aim of the study is to create an image processing system, which allows dentists to find pathological resorption and to build surgical guide surface automatically. X-rays images of jaws from cone beam tomography or spiral computed tomography are the initial data for processing. One patient's examination always includes up to 600 images (or tomograms), that's why the development of processing system for fast automation search of pathologies is necessary. X-rays images can be useful not for only illness diagnostic but for treatment planning too. We have studied the case of dental implantation - for successful surgical manipulations surgical guides are used. We have created a processing system that automatically builds jaw and teeth boundaries on the x-ray image. After this step, obtained teeth boundaries used for surgical guide surface modeling and jaw boundaries limit the area for further pathologies search. Criterion for the presence of pathological resorption zones inside the limited area is based on statistical investigation. After described actions, it is possible to manufacture surgical guide using 3D printer and apply it in surgical operation.

  3. Pilot study of design method for surgical robot using workspace reproduction system.

    Science.gov (United States)

    Seno, Hiroto; Kawamura, Kazuya; Kobayashi, Yo; Fujie, Masakatsu G

    2011-01-01

    Recent development methods for surgical robots have an inherent problem. The user-friendliness of operating robot cannot be revealed until completion of the robot. To assist the design of a surgical robot that is user-friendly in terms of surgeon's operation, we propose a system that considers the operation manner of surgeon during the design phase of the robot. This system includes the following functionality: 1) a master manipulator that measures the operation manner of the surgeon (operator), and 2) a slave simulator in which the mechanical parameters can be configured freely. The operator can use the master manipulator to operate the slave simulator. Using this system, we investigate the necessity of considering the operator's manner when developing a surgical robot. In the experiment, we used three instruments with mechanisms that differed with respect to the length between bending joints and measured the trajectory of each instrument tip position during the surgical task. The results show that there are differences in the trajectories of each mechanism. Based on the results, changes in the mechanism of the surgical robot influenced the operator's manner. Therefore, when designing the mechanism for a surgical robot, there is a need to consider how this influences the operator's manner.

  4. Effect of high intensity ultrasound on the fermentation profile of Lactobacillus sakei in a meat model system.

    Science.gov (United States)

    Ojha, Kumari Shikha; Kerry, Joseph P; Alvarez, Carlos; Walsh, Des; Tiwari, Brijesh K

    2016-07-01

    The objective of this study was to investigate the efficacy of high intensity ultrasound on the fermentation profile of Lactobacillus sakei in a meat model system. Ultrasound power level (0-68.5 W) and sonication time (0-9 min) at 20 °C were assessed against the growth of L. sakei using a Microplate reader over a period of 24h. The L. sakei growth data showed a good fit with the Gompertz model (R(2)>0.90; SEfermentation of ultrasound treated samples showed antimicrobial activity against Staphylococcus aureus, Listeria monocytogenes, Escherichia coli and Salmonella typhimurium at lower concentrations compared to control. No significant difference (pfermentation period. This study showed that both stimulation and retardation of L. sakei is possible, depending on the ultrasonic power and sonication time employed. Hence, fermentation process involving probiotics to develop functional food products can be tailored by selection of ultrasound processing parameters.

  5. Do Robotic Surgical Systems Improve Profit Margins? A Cross-Sectional Analysis of California Hospitals.

    Science.gov (United States)

    Shih, Ya-Chen Tina; Shen, Chan; Hu, Jim C

    2017-09-01

    The aim of this study was to examine the association between ownership of robotic surgical systems and hospital profit margins. This study used hospital annual utilization data, annual financial data, and discharge data for year 2011 from the California Office of Statewide Health Planning and Development. We first performed bivariate analysis to compare mean profit margin by hospital and market characteristics and to examine whether these characteristics differed between hospitals that had one or more robotic surgical systems in 2011 and those that did not. We applied the t test and the F test to compare mean profit margin between two groups and among three or more groups, respectively. We then conducted multilevel logistic regression to determine the association between ownership of robotic surgical systems and having a positive profit margin after controlling for other hospital and market characteristics and accounting for possible correlation among hospitals located within the same market. The study sample included 167 California hospitals with valid financial information. Hospitals with robotic surgical systems tended to report more favorable profit margins. However, multilevel logistic regression showed that this relationship (an association, not causality) became only marginally significant (odds ratio [OR] = 6.2; P = 0.053) after controlling for other hospital characteristics, such as ownership type, teaching status, bed size, and surgical volumes, and market characteristics, such as total number of robotic surgical systems owned by other hospitals in the same market area. As robotic surgical systems become widely disseminated, hospital decision makers should carefully evaluate the financial and clinical implications before making a capital investment in this technology. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  6. Implementation of a versatile research data acquisition system using a commercially available medical ultrasound scanner.

    Science.gov (United States)

    Hemmsen, Martin Christian; Nikolov, Svetoslav Ivanov; Pedersen, Mads Møller; Pihl, Michael Johannes; Enevoldsen, Marie Sand; Hansen, Jens Munk; Jensen, Jørgen Arendt

    2012-07-01

    This paper describes the design and implementation of a versatile, open-architecture research data acquisition system using a commercially available medical ultrasound scanner. The open architecture will allow researchers and clinicians to rapidly develop applications and move them relatively easy to the clinic. The system consists of a standard PC equipped with a camera link and an ultrasound scanner equipped with a research interface. The ultrasound scanner is an easy-to-use imaging device that is capable of generating high-quality images. In addition to supporting the acquisition of multiple data types, such as B-mode, M-mode, pulsed Doppler, and color flow imaging, the machine provides users with full control over imaging parameters such as transmit level, excitation waveform, beam angle, and focal depth. Beamformed RF data can be acquired from regions of interest throughout the image plane and stored to a file with a simple button press. For clinical trials and investigational purposes, when an identical image plane is desired for both an experimental and a reference data set, interleaved data can be captured. This form of data acquisition allows switching between multiple setups while maintaining identical transducer, scanner, region of interest, and recording time. Data acquisition is controlled through a graphical user interface running on the PC. This program implements an interface for third-party software to interact with the application. A software development toolkit is developed to give researchers and clinicians the ability to utilize third-party software for data analysis and flexible manipulation of control parameters. Because of the advantages of speed of acquisition and clinical benefit, research projects have successfully used the system to test and implement their customized solutions for different applications. Three examples of system use are presented in this paper: evaluation of synthetic aperture sequential beamformation, transverse

  7. Mammography and ultrasound in the evaluation of male breast disease

    Energy Technology Data Exchange (ETDEWEB)

    Munoz Carrasco, Rafaela; Alvarez Benito, Marina; Raya Povedano, Jose Luis [Hospital Universitario ' Reina Sofia' , Radiology Department, Cordoba (Spain); Munoz Gomariz, Elisa [Hospital Universitario ' Reina Sofia' , Support Unit for Research, Cordoba (Spain); Martinez Paredes, Maria [University of Cordoba, Radiology and Physical Medicine Area, Cordoba (Spain)

    2010-12-15

    To assess clinical variables that may be useful in differentiating gynaecomastia from carcinoma and to analyse the contribution of mammography and ultrasound to the evaluation of male breast disease. All men who underwent mammography and/or ultrasound between 1993 and 2006 in our hospital were retrospectively evaluated. Clinical characteristics in patients with gynaecomastia and those with carcinoma were compared. Radiological findings were classified according to the BI-RADS (Breast Imaging Reporting and Data System) criteria. The diagnostic performance of physical examination, mammography and ultrasound was determined and compared. A total of 628 patients with 518 mammograms and 423 ultrasounds were reviewed. The final diagnoses were: 19 carcinomas, 526 gynaecomastias, 84 other benign conditions and 25 normal. There were statistically significant differences in age, bilateral involvement, clinical presentation and physical examination between patients with carcinoma and those with gynaecomastia. The diagnostic performance of physical examination was lower than that of mammography and ultrasound (p < 0.05 for specificity). Mammography was the most sensitive (94.7%) and ultrasound the most specific (95.3%) for detection of malignancy (p > 0.05). We propose an algorithm for the use of mammography and ultrasound in men. Mammography and ultrasound, with a negative predictive value close to 100%, make it possible to avoid very many unnecessary surgical procedures in men. (orig.)

  8. Doppler ultrasound and magnetic resonance for evaluation of patients treated surgically for aortic coarctation. Ecografia Doppler y resonancia magnetica en la evaluacion de pacientes con coartacion de aorta operada

    Energy Technology Data Exchange (ETDEWEB)

    Canteli, B.; Saez, F.; Garcia, F.; Cabrera, A.; Galdeano, J.M.; Rodriguez, O. (Hospital de Cruzes, Vizcaya (Spain))

    1994-01-01

    Doppler ultrasound and magnetic resonance were performed in a series of 39 patients who had been treated surgically for aortic coarctation. The purpose was to assess the different Doppler gradients, comparing the findings with morphological data disclosed by magnetic resonance. The aortic caliber in the operative field was pathological in 7 patients (ratio between the caliber at the level of the lesion and that of descending aorta of less than 0.7). When the patients were considered as a group. Doppler ultrasound did not show satisfactory sensitivity (29%-43%), specificity (74%) or positive predictive value (17%-23%). Only the negative predictive value (85%-88%) presented more favorable results. When the Subgroup of patients without associated cardiac abnormalities or collateral circulation was studied alone, the following results were found: sensitivity, 100%; specificity, 81%-90%, positive predictive value, 33%-50%, negative predictive value, 100%, similar to those reported in the literature. Thus, we consider that Doppler ultrasound is a harmless and low cost diagnostic method that is highly suitable for follow-up of these patients, within certain limits. Magnetic resonance is the method of choice for the noninvasive assessment of aortic morphology. (Author)

  9. Patient-specific system for prognosis of surgical treatment outcomes of human cardiovascular system

    Science.gov (United States)

    Golyadkina, Anastasiya A.; Kalinin, Aleksey A.; Kirillova, Irina V.; Kossovich, Elena L.; Kossovich, Leonid Y.; Menishova, Liyana R.; Polienko, Asel V.

    2015-03-01

    Object of study: Improvement of life quality of patients with high stroke risk ia the main goal for development of system for patient-specific modeling of cardiovascular system. This work is dedicated at increase of safety outcomes for surgical treatment of brain blood supply alterations. The objects of study are common carotid artery, internal and external carotid arteries and bulb. Methods: We estimated mechanical properties of carotid arteries tissues and patching materials utilized at angioplasty. We studied angioarchitecture features of arteries. We developed and clinically adapted computer biomechanical models, which are characterized by geometrical, physical and mechanical similarity with carotid artery in norm and with pathology (atherosclerosis, pathological tortuosity, and their combination). Results: Collaboration of practicing cardiovascular surgeons and specialists in the area of Mathematics and Mechanics allowed to successfully conduct finite-element modeling of surgical treatment taking into account various features of operation techniques and patching materials for a specific patient. Numerical experiment allowed to reveal factors leading to brain blood supply decrease and atherosclerosis development. Modeling of carotid artery reconstruction surgery for a specific patient on the basis of the constructed biomechanical model demonstrated the possibility of its application in clinical practice at approximation of numerical experiment to the real conditions.

  10. MATLAB/Simulink Pulse-Echo Ultrasound System Simulator Based on Experimentally Validated Models.

    Science.gov (United States)

    Kim, Taehoon; Shin, Sangmin; Lee, Hyongmin; Lee, Hyunsook; Kim, Heewon; Shin, Eunhee; Kim, Suhwan

    2016-02-01

    A flexible clinical ultrasound system must operate with different transducers, which have characteristic impulse responses and widely varying impedances. The impulse response determines the shape of the high-voltage pulse that is transmitted and the specifications of the front-end electronics that receive the echo; the impedance determines the specification of the matching network through which the transducer is connected. System-level optimization of these subsystems requires accurate modeling of pulse-echo (two-way) response, which in turn demands a unified simulation of the ultrasonics and electronics. In this paper, this is realized by combining MATLAB/Simulink models of the high-voltage transmitter, the transmission interface, the acoustic subsystem which includes wave propagation and reflection, the receiving interface, and the front-end receiver. To demonstrate the effectiveness of our simulator, the models are experimentally validated by comparing the simulation results with the measured data from a commercial ultrasound system. This simulator could be used to quickly provide system-level feedback for an optimized tuning of electronic design parameters.

  11. [System design of small intellectualized ultrasound hyperthermia instrument in the LabVIEW environment].

    Science.gov (United States)

    Jiang, Feng; Bai, Jingfeng; Chen, Yazhu

    2005-08-01

    Small-scale intellectualized medical instrument has attracted great attention in the field of biomedical engineering, and LabVIEW (Laboratory Virtual Instrument Engineering Workbench) provides a convenient environment for this application due to its inherent advantages. The principle and system structure of the hyperthermia instrument are presented. Type T thermocouples are employed as thermotransducers, whose amplifier consists of two stages, providing built-in ice point compensation and thus improving work stability over temperature. Control signals produced by specially designed circuit drive the programmable counter/timer 8254 chip to generate PWM (Pulse width modulation) wave, which is used as ultrasound radiation energy control signal. Subroutine design topics such as inner-tissue real time feedback temperature control algorithm, water temperature control in the ultrasound applicator are also described. In the cancer tissue temperature control subroutine, the authors exert new improvments to PID (Proportional Integral Differential) algorithm according to the specific demands of the system and achieve strict temperature control to the target tissue region. The system design and PID algorithm improvement have experimentally proved to be reliable and excellent, meeting the requirements of the hyperthermia system.

  12. [The Thyroid Imaging Reporting and Data System (TIRADS) for ultrasound of the thyroid].

    Science.gov (United States)

    Russ, G; Bigorgne, C; Royer, B; Rouxel, A; Bienvenu-Perrard, M

    2011-01-01

    To develop a standardized system for analyzing and reporting thyroid ultrasound, or Thyroid Imaging Reporting and Data System (TIRADS), in order to improve the management of patients with thyroid nodules. An atlas of imaging features, a standardized vocabulary, a report template and TIRADS categories 0 to 6 were defined, based on the BI-RADS system used for mammography. The diagnostic efficacy of the system was tested by a retrospective review of 500 nodules (159 cancers and 341 benign nodules) and comparing US imaging features to histological findings. Five signs allow accurate detection of 90% of thyroid cancers. The score of a nodule can be easily defined by using an organigram. Sensitivity, specificity and odds-ratio of the score were respectively 95%, 68% and 40. TIRADS is a quality assurance tool for thyroid ultrasound. It contains an image atlas, a standardized report and categories to evaluate thyroid nodules to easily assess the risk of individual nodules being cancers and facilitate patient management. Copyright © 2011 Elsevier Masson SAS and Éditions françaises de radiologie. All rights reserved.

  13. Efficient microbubble- and ultrasound-mediated plasmid DNA delivery into a specific rat liver lobe via a targeted injection and acoustic exposure using a novel ultrasound system.

    Science.gov (United States)

    Song, Shuxian; Noble, Misty; Sun, Samuel; Chen, Liping; Brayman, Andrew A; Miao, Carol H

    2012-08-06

    To develop efficient gene delivery in larger animals, based on a previous mouse study, we explored the luciferase reporter gene transfer in rats by establishing a novel unfocused ultrasound system with simultaneous targeted injection of a plasmid and microbubble mixture into a specific liver lobe through a portal vein branch. Luciferase expression was significantly enhanced over 0-30 vol % of the Definity microbubbles, with a plateau between 0.5 and 30 vol %. The increase of gene delivery efficiency also depended on the acoustic peak negative pressure, achieving over 100-fold enhancement at 2.5 MPa compared with plasmid only controls. Transient, modest liver damage following treatment was assessed by transaminase assays and histology, both of which correlated with gene expression induced by acoustic cavitation. In addition, pulse-train ultrasound exposures (i.e., with relatively long quiescent periods between groups of pulses to allow tissue refill with microbubbles) produced gene expression levels comparable to the standard US exposure but reduced the extent of liver damage. These results indicated that unfocused high intensity therapeutic ultrasound exposure with microbubbles is highly promising for safe and efficient gene delivery into the liver of rats or larger animals.

  14. System Level Design of a Continuous-Time Delta-Sigma Modulator for Portable Ultrasound Scanners

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Færch, Kjartan; Jørgensen, Ivan Harald Holger;

    2015-01-01

    In this paper the system level design of a continuous-time ∆Σ modulator for portable ultrasound scanners is presented. The overall required signal-to-noise ratio (SNR) is derived to be 42 dB and the sampling frequency used is 320 MHz for an oversampling ratio of 16. In order to match these requir......, based on high-level VerilogA simulations, the performance of the ∆Σ modulator versus various block performance parameters is presented as trade-off curves. Based on these results, the block specifications are derived....

  15. System-Level Design of an Integrated Receiver Front End for a Wireless Ultrasound Probe

    DEFF Research Database (Denmark)

    di Ianni, Tommaso; Hemmsen, Martin Christian; Llimos Muntal, Pere;

    2016-01-01

    In this paper, a system-level design is presented for an integrated receive circuit for a wireless ultrasound probe, which includes analog front ends and beamformation modules. This paper focuses on the investigation of the effects of architectural design choices on the image quality. The point......). The designs that minimally satisfy the specifications are based on an 8-b 30-MSPS Nyquist converter and a single-bit third-order 240-MSPS modulator, with an SNR for the LNA in both cases equal to 64 dB. The mean lateral FWHM and CR are 2.4% and 7.1% lower for the architecture compared with the Nyquistrate one...

  16. Nonviral gene delivery systems by the combination of bubble liposomes and ultrasound.

    Science.gov (United States)

    Omata, Daiki; Negishi, Yoichi; Suzuki, Ryo; Oda, Yusuke; Endo-Takahashi, Yoko; Maruyama, Kazuo

    2015-01-01

    The combination of therapeutic ultrasound (US) and nano/microbubbles is an important system for establishing a novel and noninvasive gene delivery system. Genes are delivered more efficiently using this system compared with a conventional nonviral vector system such as the lipofection method, resulting in higher gene expression. This higher efficiency is due to the gene being delivered into the cytosol and bypassing the endocytosis pathway. Many in vivo studies have demonstrated US-mediated gene delivery with nano/microbubbles, and several gene therapy feasibility studies for various diseases have been reported. In addition, nano/microbubbles can deliver genes site specifically by the control of US exposure site. In the present review, we summarize the gene delivery systems by the combination of nano/microbubbles and US, describe their properties, and assess applications and challenges of US theranostics.

  17. High-Quality See-Through Surgical Guidance System Using Enhanced 3-D Autostereoscopic Augmented Reality.

    Science.gov (United States)

    Zhang, Xinran; Chen, Guowen; Liao, Hongen

    2017-08-01

    Precise minimally invasive surgery (MIS) has significant advantages over traditional open surgery in clinic. Although pre-/intraoperative diagnosis images can provide necessary guidance for therapy, hand-eye discoordination occurs when guidance information is displayed away from the surgical area. In this study, we introduce a real three-dimensional (3-D) see-through guidance system for precision surgery. To address the resolution and viewing angle limitation as well as the accuracy degradation problems of autostereoscopic 3-D display, we design a high quality and high accuracy 3-D integral videography (IV) medical image display method. Furthermore, a novel see-through microscopic device is proposed to assist surgeons with the superimposition of real 3-D guidance onto the surgical target is magnified by an optical visual magnifier module. Spatial resolutions of 3-D IV image in different depths have been increased 50%∼70%, viewing angles of different image sizes have been increased 9%∼19% compared with conventional IV display methods. Average accuracy of real 3-D guidance superimposed on surgical target was 0.93 mm ± 0.41 mm. Preclinical studies demonstrated that our system could provide real 3-D perception of anatomic structures inside the patient's body. The system showed potential clinical feasibility to provide intuitive and accurate in situ see-through guidance for microsurgery without restriction on observers' viewing position. Our system can effectively improve the precision and reliability of surgical guidance. It will have wider applicability in surgical planning, microscopy, and other fields.

  18. A cable-driven soft robot surgical system for cardiothoracic endoscopic surgery: preclinical tests in animals.

    Science.gov (United States)

    Wang, Hesheng; Zhang, Runxi; Chen, Weidong; Wang, Xiaozhou; Pfeifer, Rolf

    2017-08-01

    Minimally invasive surgery attracts more and more attention because of the advantages of minimal trauma, less bleeding and pain and low complication rate. However, minimally invasive surgery for beating hearts is still a challenge. Our goal is to develop a soft robot surgical system for single-port minimally invasive surgery on a beating heart. The soft robot described in this paper is inspired by the octopus arm. Although the octopus arm is soft and has more degrees of freedom (DOFs), it can be controlled flexibly. The soft robot is driven by cables that are embedded into the soft robot manipulator and can control the direction of the end and middle of the soft robot manipulator. The forward, backward and rotation movement of the soft robot is driven by a propulsion plant. The soft robot can move freely by properly controlling the cables and the propulsion plant. The soft surgical robot system can perform different thoracic operations by changing surgical instruments. To evaluate the flexibility, controllability and reachability of the designed soft robot surgical system, some testing experiments have been conducted in vivo on a swine. Through the subxiphoid, the soft robot manipulator could enter into the thoracic cavity and pericardial cavity smoothly and perform some operations such as biopsy, ligation and ablation. The operations were performed successfully and did not cause any damage to the surrounding soft tissues. From the experiments, the flexibility, controllability and reachability of the soft robot surgical system have been verified. Also, it has been shown that this system can be used in the thoracic and pericardial cavity for different operations. Compared with other endoscopy robots, the soft robot surgical system is safer, has more DOFs and is more flexible for control. When performing operations in a beating heart, this system maybe more suitable than traditional endoscopy robots.

  19. A system analysis of a suboptimal surgical experience

    Directory of Open Access Journals (Sweden)

    Richards Michael

    2009-01-01

    Full Text Available Abstract Background System analyses of incidents that occur in the process of health care delivery are rare. A case study of a series of incidents that one of the authors experienced after routine urologic surgery is presented. We interpret the sequence of events as a case of cascading incidents that resulted in outcomes that were suboptimal, although fortunately not fatal. Methods A system dynamics approach was employed to develop illustrative models (flow diagrams of the dynamics of the patient's interaction with surgery and emergency departments. The flow diagrams were constructed based upon the experience of the patient, chart review, discussion with the involved physicians as well as several physician colleagues, comparison of our diagrams with those developed by the hospital of interest for internal planning purposes, and an iterative process with one of the co-authors who is a system dynamics expert. A dynamic hypothesis was developed using insights gained by building the flow diagrams. Results The incidents originated in design flaws and many small innocuous system changes that have occurred incrementally over time, which by themselves may have no consequence but in conjunction with some system randomness can have serious consequences. In the patient's case, the incidents that occurred in preoperative assessment and surgery originated in communication and procedural failures. System delays, communication failures, and capacity issues contributed largely to the subsequent incidents. Some of these issues were controllable by the physicians and staff of the institution, whereas others were less controllable. To the system's credit, some of the more controllable issues were addressed, but systemic problems like overcrowding are unlikely to be addressed in the near future. Conclusion This is first instance that we are aware of in the literature where a system dynamics approach has been used to analyze a patient safety experience. The

  20. In vivo photoacoustic imaging of nude mice vasculature using a photoacoustic imaging system based on a commercial ultrasound scanner

    Science.gov (United States)

    Jankovic, Ladislav; Shahzad, Khalid; Wang, Yao; Burcher, Michael; Scholle, Frank-Detlef; Hauff, Peter; Mofina, Sabine; Skobe, Mihaela

    2008-02-01

    In-vivo photoacoustic/ultrasound (PA/US) imaging of nude mice was investigated using a photoacoustic imaging system based on a commercial ultrasound scanner HDI-5000. Raw per-channel data was captured and beamformed to generate each individual photoacoustic image with a single laser shot. An ultra-broadband CL15-7 linear array with a center frequency of 8 MHz, combined with a Schott Glass fiber bundle, was used as a compact high resolution imaging probe, with lateral and axial PA resolutions of about 300µm and 200µm, respectively. The imaging system worked in a dual PA-US mode, with the ultrasound outlining the tissue structure and the photoacoustic image showing the blood vessels. PA signals were generated by exposing mice to ultra-short optical pulses from a Nd:YAG-pumped OPO laser operating in a wavelength range of 700-950nm. The corresponding ultrasound images were generated in the regular B-mode with standard delay-and-sum beamforming algorithm. The system resolution was sufficiently high to identify and clearly distinguish the dorsal artery and the two lateral veins in the mouse tail. Both the saphena artery and the ischiatic vein on the cross-section of the mouse leg were clearly outlined in the PA images and correctly overlaid on the ultrasound image of the tissue structure. Similarly, cross-section PA images of the mouse abdomen revealed mesenteric vasculatures located below the abdominal wall. Finally, a successful PA imaging of the mouse thoracic cavity unveiled the ascending and descending aorta. These initial results demonstrate a great potential for a dual photoacoustic/ultrasound imaging modality implemented on a commercial ultrasound imaging scanner.

  1. A Google Glass navigation system for ultrasound and fluorescence dual-mode image-guided surgery

    Science.gov (United States)

    Zhang, Zeshu; Pei, Jing; Wang, Dong; Hu, Chuanzhen; Ye, Jian; Gan, Qi; Liu, Peng; Yue, Jian; Wang, Benzhong; Shao, Pengfei; Povoski, Stephen P.; Martin, Edward W.; Yilmaz, Alper; Tweedle, Michael F.; Xu, Ronald X.

    2016-03-01

    Surgical resection remains the primary curative intervention for cancer treatment. However, the occurrence of a residual tumor after resection is very common, leading to the recurrence of the disease and the need for re-resection. We develop a surgical Google Glass navigation system that combines near infrared fluorescent imaging and ultrasonography for intraoperative detection of sites of tumor and assessment of surgical resection boundaries, well as for guiding sentinel lymph node (SLN) mapping and biopsy. The system consists of a monochromatic CCD camera, a computer, a Google Glass wearable headset, an ultrasonic machine and an array of LED light sources. All the above components, except the Google Glass, are connected to a host computer by a USB or HDMI port. Wireless connection is established between the glass and the host computer for image acquisition and data transport tasks. A control program is written in C++ to call OpenCV functions for image calibration, processing and display. The technical feasibility of the system is tested in both tumor simulating phantoms and in a human subject. When the system is used for simulated phantom resection tasks, the tumor boundaries, invisible to the naked eye, can be clearly visualized with the surgical Google Glass navigation system. This system has also been used in an IRB approved protocol in a single patient during SLN mapping and biopsy in the First Affiliated Hospital of Anhui Medical University, demonstrating the ability to successfully localize and resect all apparent SLNs. In summary, our tumor simulating phantom and human subject studies have demonstrated the technical feasibility of successfully using the proposed goggle navigation system during cancer surgery.

  2. Endocavity Ultrasound Probe Manipulators.

    Science.gov (United States)

    Stoianovici, Dan; Kim, Chunwoo; Schäfer, Felix; Huang, Chien-Ming; Zuo, Yihe; Petrisor, Doru; Han, Misop

    2013-06-01

    We developed two similar structure manipulators for medical endocavity ultrasound probes with 3 and 4 degrees of freedom (DoF). These robots allow scanning with ultrasound for 3-D imaging and enable robot-assisted image-guided procedures. Both robots use remote center of motion kinematics, characteristic of medical robots. The 4-DoF robot provides unrestricted manipulation of the endocavity probe. With the 3-DoF robot the insertion motion of the probe must be adjusted manually, but the device is simpler and may also be used to manipulate external-body probes. The robots enabled a novel surgical approach of using intraoperative image-based navigation during robot-assisted laparoscopic prostatectomy (RALP), performed with concurrent use of two robotic systems (Tandem, T-RALP). Thus far, a clinical trial for evaluation of safety and feasibility has been performed successfully on 46 patients. This paper describes the architecture and design of the robots, the two prototypes, control features related to safety, preclinical experiments, and the T-RALP procedure.

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... are the limitations of Prostate Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe ... transducer into the body. top of page How is the procedure performed? In men, the prostate gland ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Pelvis Ultrasound imaging of the pelvis uses sound waves to produce pictures of the structures and organs ... of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or sonography , ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a pelvic ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  7. Intravascular ultrasound

    Science.gov (United States)

    IVUS; Ultrasound - coronary artery; Endovascular ultrasound; Intravascular echocardiography ... A tiny ultrasound wand is attached to the top of a thin tube. This tube is called a catheter. The catheter ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently ... pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Obstetrical Ultrasound page for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: ...

  10. High-intensity ultrasound production of Maillard reaction flavor compounds in a cysteine-xylose model system.

    Science.gov (United States)

    Ong, Olivia X H; Seow, Yi-Xin; Ong, Peter K C; Zhou, Weibiao

    2015-09-01

    Application of high intensity ultrasound has shown potential in the production of Maillard reaction odor-active flavor compounds in model systems. The impact of initial pH, sonication duration, and ultrasound intensity on the production of Maillard reaction products (MRPs) by ultrasound processing in a cysteine-xylose model system were evaluated using Response Surface Methodology (RSM) with a modified mathematical model. Generation of selected MRPs, 2-methylthiophene and tetramethyl pyrazine, was optimal at an initial pH of 6.00, accompanied with 78.1 min of processing at an ultrasound intensity of 19.8 W cm(-2). However, identification of volatiles using gas chromatography-mass spectrometry (GC/MS) revealed that ultrasound-assisted Maillard reactions generated fewer sulfur-containing volatile flavor compounds as compared to conventional heat treatment of the model system. Likely reasons for this difference in flavor profile include the expulsion of H2S due to ultrasonic degassing and inefficient transmission of ultrasonic energy. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. System Level Design of a Continuous-Time Delta-Sigma Modulator for Portable Ultrasound Scanners

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Færch, Kjartan; Jørgensen, Ivan Harald Holger

    2015-01-01

    In this paper the system level design of a continuous-time ∆Σ modulator for portable ultrasound scanners is presented. The overall required signal-to-noise ratio (SNR) is derived to be 42 dB and the sampling frequency used is 320 MHz for an oversampling ratio of 16. In order to match these requir......In this paper the system level design of a continuous-time ∆Σ modulator for portable ultrasound scanners is presented. The overall required signal-to-noise ratio (SNR) is derived to be 42 dB and the sampling frequency used is 320 MHz for an oversampling ratio of 16. In order to match...... these requirements, a fourth order, 1-bit modulator with optimal zero placing is used. An analysis shows that the thermal noise from the resistors and operational transconductance amplifier is not a limiting factor due to the low required SNR, leading to an inherently very low-power implementation. Furthermore......, based on high-level VerilogA simulations, the performance of the ∆Σ modulator versus various block performance parameters is presented as trade-off curves. Based on these results, the block specifications are derived....

  12. In vitro cell system for studying molecular mechanisms of action associated with low intensity focused ultrasound

    Science.gov (United States)

    Babakhanian, Meghedi; Fan, Richard E.; Mulgaonkar, Amit P.; Singh, Rahul; Culjat, Martin O.; Danesh, Shahab M.; Toro, Ligia; Grundfest, Warren; Melega, William P.

    2012-03-01

    Low intensity focused ultrasound (LIFU) is now being considered as a noninvasive brain therapy for clinical applications. We maintain that LIFU can efficiently deliver energy from outside the skull to target specific brain regions, effecting localized neuromodulation. However, the underlying molecular mechanisms that drive this LIFU-induced neuromodulation are not well-defined due, in part, to our lack of understanding of how particular sets of LIFU delivery parameters affect the outcome. To efficiently conduct multiple sweeps of different parameters and determine their effects, we have developed an in-vitro system to study the effects of LIFU on different types of cells grown in culture. Presently, we are evaluating how LIFU affects the ionic flux that may underlie neuronal excitation and inhibition observed in-vivo. The results of our in-vitro studies will provide a rationale for selection of optimal LIFU parameter to be used in subsequent in-vivo applications. Thus, a prototype ultrasound cell assay system has been developed to conduct these studies, and is described in this work.

  13. A Fully Sensorized Cooperative Robotic System for Surgical Interventions

    Directory of Open Access Journals (Sweden)

    Saúl Tovar-Arriaga

    2012-07-01

    Full Text Available In this research a fully sensorized cooperative robot system for manipulation of needles is presented. The setup consists of a DLR/KUKA Light Weight Robot III especially designed for safe human/robot interaction, a FD-CT robot-driven angiographic C-arm system, and a navigation camera. Also, new control strategies for robot manipulation in the clinical environment are introduced. A method for fast calibration of the involved components and the preliminary accuracy tests of the whole possible errors chain are presented. Calibration of the robot with the navigation system has a residual error of 0.81 mm (rms with a standard deviation of ±0.41 mm. The accuracy of the robotic system while targeting fixed points at different positions within the workspace is of 1.2 mm (rms with a standard deviation of ±0.4 mm. After calibration, and due to close loop control, the absolute positioning accuracy was reduced to the navigation camera accuracy which is of 0.35 mm (rms. The implemented control allows the robot to compensate for small patient movements.

  14. A Fully Sensorized Cooperative Robotic System for Surgical Interventions

    Science.gov (United States)

    Tovar-Arriaga, Saúl; Vargas, José Emilio; Ramos, Juan M.; Aceves, Marco A.; Gorrostieta, Efren; Kalender, Willi A.

    2012-01-01

    In this research a fully sensorized cooperative robot system for manipulation of needles is presented. The setup consists of a DLR/KUKA Light Weight Robot III especially designed for safe human/robot interaction, a FD-CT robot-driven angiographic C-arm system, and a navigation camera. Also, new control strategies for robot manipulation in the clinical environment are introduced. A method for fast calibration of the involved components and the preliminary accuracy tests of the whole possible errors chain are presented. Calibration of the robot with the navigation system has a residual error of 0.81 mm (rms) with a standard deviation of ±0.41 mm. The accuracy of the robotic system while targeting fixed points at different positions within the workspace is of 1.2 mm (rms) with a standard deviation of ±0.4 mm. After calibration, and due to close loop control, the absolute positioning accuracy was reduced to the navigation camera accuracy which is of 0.35 mm (rms). The implemented control allows the robot to compensate for small patient movements. PMID:23012551

  15. Multi-processor system for real-time deconvolution and flow estimation in medical ultrasound

    DEFF Research Database (Denmark)

    Jensen, Jesper Lomborg; Jensen, Jørgen Arendt; Stetson, Paul F.

    1996-01-01

    filter is used with a second time-reversed recursive estimation step. Here it is necessary to perform about 70 arithmetic operations per RF sample or about 1 billion operations per second for real-time deconvolution. Furthermore, these have to be floating point operations due to the adaptive nature...... of the algorithms. Many of the algorithms can only be properly evaluated in a clinical setting with real-time processing, which generally cannot be done with conventional equipment. This paper therefore presents a multi-processor system capable of performing 1.2 billion floating point operations per second on RF...... of the system is its generous input/output bandwidth, that makes it easy to balance the computational load between the processors and prevents data starvation. Due to the use of floating point calculations it is possible to simulate all types of signal processing in modem ultrasound scanners, and this system is...

  16. Essential Tremor (ET): Surgical Options

    Science.gov (United States)

    ... t respond to propranolol, primidone, or other common ET medications and whose tremor has become debilitating, there ... treatments were first introduced. Current surgical options for ET include Deep Brain Stimulation (DBS) , Focused Ultrasound Thalamotomy , ...

  17. SURGNET: An Integrated Surgical Data Transmission System for Telesurgery

    Directory of Open Access Journals (Sweden)

    Sriram Natarajan

    2009-01-01

    Full Text Available Remote surgery information requires quick and reliable transmission between the surgeon and the patient site. However, the networks that interconnect the surgeon and patient sites are usually time varying and lossy which can cause packet loss and delay jitter. In this paper we propose SURGNET, a telesurgery system for which we developed the architecture, algorithms and implemented it on a testbed. The algorithms include adaptive packet prediction and buffer time adjustment techniques which reduce the negative effects caused by the lossy and time varying networks. To evaluate the proposed SURGNET system, at the therapist site, we implemented a therapist panel which controls the force feedback device movements and provides image analysis functionality. At the patient site we controlled a virtual reality applet built in Matlab. The varying network conditions were emulated using NISTNet emulator. Our results show that even for severe packet loss and variable delay jitter, the proposed integrated synchronization techniques significantly improve SURGNET performance.

  18. The surgical anatomy of the lymphatic system of the pancreas.

    Science.gov (United States)

    Cesmebasi, Alper; Malefant, Jason; Patel, Swetal D; Du Plessis, Maira; Renna, Sarah; Tubbs, R Shane; Loukas, Marios

    2015-05-01

    The lymphatic system of the pancreas is a complex, intricate network of lymphatic vessels and nodes responsible for the drainage of the head, neck, body, and tail of the pancreas. Its anatomical divisions and embryological development have been well described in the literature with emphasis on its clinical relevance in regards to pancreatic pathologies. A thorough knowledge and understanding of the lymphatic system surrounding the pancreas is critical for physicians in providing diagnostic and treatment strategies for patients with pancreatic cancer and pancreatitis. Pancreatic cancer has an extremely poor prognosis and is a notable cause of morbidity and mortality worldwide. Although a surgeon may try to predict the routes for metastasis for pancreatic cancer, the complexity of this system presents difficulty due to variable drainage patterns. Pancreatitis also presents as another severe disease which has been shown to have an association with the lymphatics. The aim of this article is to review the literature on the lymphatics of the pancreas, pancreatic pathologies, and the available imaging methodologies used to study the pancreatic lymphatics.

  19. An image-guidance system for dynamic dose calculation in prostate brachytherapy using ultrasound and fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kuo, Nathanael, E-mail: nkuo8@jhmi.edu; Prince, Jerry L. [Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Dehghan, Ehsan [Philips Research North America, Briarcliff Manor, New York 10510 (United States); Deguet, Anton [Department of Computer Science, Johns Hopkins University, Baltimore, Maryland 21218 (United States); Mian, Omar Y.; Le, Yi; Song, Danny Y. [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland 21231 (United States); Burdette, E. Clif [Acoustic MedSystems Inc., Savoy, Illinois 61974 (United States); Fichtinger, Gabor [School of Computing, Queen' s University, Kingston, Ontario K7L3N6 (Canada); Lee, Junghoon [Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, Maryland 21218 and Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland 21231 (United States)

    2014-09-15

    Purpose: Brachytherapy is a standard option of care for prostate cancer patients but may be improved by dynamic dose calculation based on localized seed positions. The American Brachytherapy Society states that the major current limitation of intraoperative treatment planning is the inability to localize the seeds in relation to the prostate. An image-guidance system was therefore developed to localize seeds for dynamic dose calculation. Methods: The proposed system is based on transrectal ultrasound (TRUS) and mobile C-arm fluoroscopy, while using a simple fiducial with seed-like markers to compute pose from the nonencoded C-arm. Three or more fluoroscopic images and an ultrasound volume are acquired and processed by a pipeline of algorithms: (1) seed segmentation, (2) fiducial detection with pose estimation, (3) seed matching with reconstruction, and (4) fluoroscopy-to-TRUS registration. Results: The system was evaluated on ten phantom cases, resulting in an overall mean error of 1.3 mm. The system was also tested on 37 patients and each algorithm was evaluated. Seed segmentation resulted in a 1% false negative rate and 2% false positive rate. Fiducial detection with pose estimation resulted in a 98% detection rate. Seed matching with reconstruction had a mean error of 0.4 mm. Fluoroscopy-to-TRUS registration had a mean error of 1.3 mm. Moreover, a comparison of dose calculations between the authors’ intraoperative method and an independent postoperative method shows a small difference of 7% and 2% forD{sub 90} and V{sub 100}, respectively. Finally, the system demonstrated the ability to detect cold spots and required a total processing time of approximately 1 min. Conclusions: The proposed image-guidance system is the first practical approach to dynamic dose calculation, outperforming earlier solutions in terms of robustness, ease of use, and functional completeness.

  20. Compact teleoperated laparoendoscopic single-site robotic surgical system: Kinematics, control, and operation.

    Science.gov (United States)

    Isaac-Lowry, Oran Jacob; Okamoto, Steele; Pedram, Sahba Aghajani; Woo, Russell; Berkelman, Peter

    2017-03-27

    To date a variety of teleoperated surgical robotic systems have been developed to improve a surgeon's ability to perform demanding single-port procedures. However typical large systems are bulky, expensive, and afford limited angular motion, while smaller designs suffer complications arising from limited motion range, speed, and force generation. This work was to develop and validate a simple, compact, low cost single site teleoperated laparoendoscopic surgical robotic system, with demonstrated capability to carry out basic surgical procedures. This system builds upon previous work done at the University of Hawaii at Manoa and includes instrument and endoscope manipulators as well as compact articulated instruments designed to overcome single incision geometry complications. A robotic endoscope holder was used for the base, with an added support frame for teleoperated manipulators and instruments fabricated mostly from 3D printed parts. Kinematics and control methods were formulated for the novel manipulator configuration. Trajectory following results from an optical motion tracker and sample task performance results are presented. Results indicate that the system has successfully met the goal of basic surgical functionality while minimizing physical size, complexity, and cost. Copyright © 2017 John Wiley & Sons, Ltd.

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: ...

  2. Clinician-performed thyroid ultrasound.

    Science.gov (United States)

    Coltrera, Marc D

    2014-08-01

    This article is intended to demystify the process for those with a potential interest in acquiring ultrasound skills. It is not intended to be a comprehensive review of head and neck ultrasound but, rather, is focused on the bare minimum requirements and considerations involved in clinician-performed ultrasound. The article covers the initial diagnosis and the unparalleled usefulness of ultrasound for surgical planning just before incision. Further readings are listed at the end of the article to direct the reader to some excellent texts to help build confidence and experience.

  3. Evaluation of bacterial contamination on surgical drapes following use of the Bair Hugger(®) forced air warming system.

    Science.gov (United States)

    Occhipinti, Lindsay L; Hauptman, Joe G; Greco, Justin J; Mehler, Stephen J

    2013-12-01

    This pilot study determined the rate of bacterial contamination on surgical drapes of small animal patients warmed intra-operatively with the Bair Hugger(®) forced air warming system compared to a control method. Surgical drapes of 100 patients undergoing clean surgical procedures were swabbed with aerobic culturettes at the beginning and end of surgery. Samples were cultured on Trypticase soy agar. Contamination of the surgical drapes was identified in 6/98 cases (6.1%). There was no significant difference in the number of contaminated surgical drapes between the Bair Hugger(®) and control groups (P = 0.47).

  4. A novel thyroid cancer nodal map classification system to facilitate nodal localization and surgical management: The A to D map.

    Science.gov (United States)

    Cunnane, Marybeth; Kyriazidis, Natalia; Kamani, Dipti; Juliano, Amy F; Kelly, Hillary R; Curtin, Hugh D; Barber, Samuel R; Randolph, Gregory W

    2016-11-30

    To evaluate the effectiveness, reproducibility, and usability of our proposed nodal nomenclature and classification system employed for several years in our high-volume thyroid cancer unit, for the adequate localization and mapping of lymph nodes in thyroid cancer patients with extensive nodal disease. Retrospective review. Thirty-three thyroid cancer patients with extensive nodal disease treated from January 2004 to May 2013 were included in our study. Preoperative ultrasound and computed tomography scans of these patients were reanalyzed by blinded radiologists to investigate the feasibility for the assignment of abnormal lymph nodes to compartments defined in our proposed nodal classification system and to identify areas of difficulty in the assignment. Analysis of nodal localization revealed a discrepancy in compartment agreement between the two radiologists in the assignment of abnormal nodes in nine patients (9/33, 27%). In six patients (6/33, 18%), discrepancy existed in labeling paratracheal and pretracheal nodes. In three patients (3/33, 9%), disagreement arose in the classification of retrocarotid nodes into lateral versus central compartment. A further refinement of the definition of key borderline regions of the pretracheal versus paratracheal and retrocarotid regions of our classification improved the agreement and demonstrated a complete concordance (100%) amongst the reviewing radiologists. The proposed nodal classification system, derived specifically for differentiated thyroid carcinoma, with readily identifiable anatomic boundaries on imaging and at surgery, facilitates communication among multidisciplinary physicians and aids in creating a uniform and reproducible radiographic nodal map to guide surgical therapy. 4 Laryngoscope, 2016. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  5. Preoperative RFA simulation for liver cancer using a CT virtual ultrasound system

    Energy Technology Data Exchange (ETDEWEB)

    Kudo, Kosei [Fourth Department of Gastroenterology and Hepatology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjukuku-ku, Tokyo 160-0023 (Japan); Moriyasu, Fuminori [Fourth Department of Gastroenterology and Hepatology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjukuku-ku, Tokyo 160-0023 (Japan)]. E-mail: moriyasu@tokyo-med.ac.jp; Mine, Yoshitaka [R and D, Toshiba Medical Systems Co., Tokyo (Japan); Miyata, Yuki [Fourth Department of Gastroenterology and Hepatology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjukuku-ku, Tokyo 160-0023 (Japan); Sugimoto, Katsutoshi [Fourth Department of Gastroenterology and Hepatology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjukuku-ku, Tokyo 160-0023 (Japan); Metoki, Ryou [Fourth Department of Gastroenterology and Hepatology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjukuku-ku, Tokyo 160-0023 (Japan); Kamamoto, Hiroyuki [Fourth Department of Gastroenterology and Hepatology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjukuku-ku, Tokyo 160-0023 (Japan); Suzuki, Shirou [Fourth Department of Gastroenterology and Hepatology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjukuku-ku, Tokyo 160-0023 (Japan); Shimizu, Masafumi [Fourth Department of Gastroenterology and Hepatology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjukuku-ku, Tokyo 160-0023 (Japan); Miyahara, Takeo [Fourth Department of Gastroenterology and Hepatology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjukuku-ku, Tokyo 160-0023 (Japan); Yokoi, Masato [Fourth Department of Gastroenterology and Hepatology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjukuku-ku, Tokyo 160-0023 (Japan); Horibe, Toshiya [Fourth Department of Gastroenterology and Hepatology, Tokyo Medical University, 6-7-1 Nishishinjuku, Shinjukuku-ku, Tokyo 160-0023 (Japan); Yamagata, Hitoshi [R and D, Toshiba Medical Systems Co., Tokyo (Japan)

    2007-02-15

    We developed a computed tomography (CT) virtual ultrasound system (CVUS) as an imaging system to support treatment under percutaneous ultrasound (US) guidance. This prototype clinical system, produced in collaboration with Tokyo Medical University, uses display software developed by Toshiba Medical Systems. We examined the utility of this system by scheduling treatment plans preoperatively and simulating puncture and radiofrequency ablation (RFA) for liver cancer. The study enrolled 51 liver cancer patients with 66 nodules 0.8-8 cm in diameter in which RFA was performed between June 2004 and December 2004. Virtual US and multiplanar reconstruction (MPR) images were constructed on the basis of DICOM CT data and puncture and ablation of liver cancer were simulated. The following were evaluated: (1) how to avoid complications and determine an appropriate puncture route by simulating puncture with C-mode MPR images; (2) determination of the three-dimensional location of the tumor for ablation, as well as the adjacent organs and vessels, by MPR rotation 360{sup o} around the center of the tumor (center lock); and (3) how to determine the center and volume of ablation and avoid injuries to nearby organs and vessels by simulating ablation procedures. C -mode MPR images were effective for (1) determining and modifying the puncture route in 35 of 51 cases (69.6%) and (2) determining the spatial location of vessels and nearby organs in 50 of 51 cases (98.0%) by the center lock; and (3) simulating the ablation helped determine the center and volume of ablation by avoiding injuries to vessels and nearby organs in 45 or 51 cases (88.2%). Taken together, the CVUS allowed easy simulation of local treatment of liver cancer under US guidance using CT data alone and the preoperative simulation predicted an improvement in the safety of local therapy of liver cancer.

  6. 3-D microvessel-mimicking ultrasound phantoms produced with a scanning motion system.

    Science.gov (United States)

    Gessner, Ryan C; Kothadia, Roshni; Feingold, Steven; Dayton, Paul A

    2011-05-01

    Ultrasound techniques are currently being developed that can assess the vascularization of tissue as a marker for therapeutic response. Some of these ultrasound imaging techniques seek to extract quantitative features about vessel networks, whereas high-frequency imaging also allows individual vessels to be resolved. The development of these new techniques, and subsequent imaging analysis strategies, necessitates an understanding of their sensitivities to vessel and vessel network structural abnormalities. Constructing in-vitro flow phantoms for this purpose can be prohibitively challenging, because simulating precise flow environments with nontrivial structures is often impossible using conventional methods of construction for flow phantoms. Presented in this manuscript is a method to create predefined structures with precision using a three-axis motion system. The application of this technique is demonstrated for the creation of individual vessel and vessel networks, which can easily be made to simulate the development of structural abnormalities typical of diseased vasculature in vivo. In addition, beyond facilitating the creation of phantoms that would otherwise be very challenging to construct, the method presented herein enables one to precisely simulate very slow blood flow and respiration artifacts, and to measure imaging resolution.

  7. Ultrasound Findings on Hands and Wrists of Patients with Systemic Lupus Erythematosus: Relationship with Physical Examination.

    Science.gov (United States)

    Lins, Carolina Freitas; Lima de Sá Ribeiro, Daniel; Dourado Santos, Willer Gonçalves; Rosa, Genevievi; Machicado, Viviane; Pedreira, Ana Luisa; Pimenta da Fonseca, Emanuela; Mota Duque Sousa, Anna Paula; Rodrigues Silva, Carla Baleeiro; Matos, Marcos Antonio Almeida; Santiago, Mittermayer Barreto

    2017-09-01

    Diagnosis of synovitis/tenosynovitis by physical examination can be difficult. Ultrasound (US) can be an effective tool for the evaluation of joint involvement in systemic lupus erythematosus (SLE). This study will describe musculoskeletal findings by US in SLE patients and the evaluation of their correlation with physical examination. SLE patients underwent clinical/sonographic evaluation of hand/wrists. In total, 896 joints were evaluated: at least 1 change on physical examination was found in 136 joints and at least 1 US abnormality was found in 65 of 896 joints. Out of the 65 joints with US changes, only 13 had findings on physical examination. Conversely, 111 joints had tenderness on physical examination with no sonographic abnormalities. Tenosynovitis was statistically significant more frequently with joint edema (41%) (p = 0.0003). US can detect musculoskeletal changes in only a minority of symptomatic SLE patients. Clinical findings may be related to some reasons that cannot be explained using US. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. The surgical algorithm for the AOSpine thoracolumbar spine injury classification system

    NARCIS (Netherlands)

    Vaccaro, Alexander R.; Schroeder, Gregory D.; Kepler, Christopher K.; Cumhur Oner, F.; Vialle, Luiz R.; Kandziora, Frank; Koerner, John D.; Kurd, Mark F.; Reinhold, Max; Schnake, Klaus J.; Chapman, Jens; Aarabi, Bizhan; Fehlings, Michael G.; Dvorak, Marcel F.

    2016-01-01

    Purpose: The goal of the current study is to establish a surgical algorithm to accompany the AOSpine thoracolumbar spine injury classification system. Methods: A survey was sent to AOSpine members from the six AO regions of the world, and surgeons were asked if a patient should undergo an initial tr

  9. LED surgical lighting system with multiple free-form surfaces for highly sterile operating theater application.

    Science.gov (United States)

    Liu, Peng; Zhang, Yaqin; Zheng, Zhenrong; Li, Haifeng; Liu, Xu

    2014-06-01

    Although the ventilation system is widely employed in the operating theater, a strictly sterile surgical environment still cannot be ensured because of laminar disturbance, which is mainly caused by the surgical lighting system. Abandoning traditional products, we propose an LED surgical lighting system, which can alleviate the laminar disturbance and provide an appropriate lighting condition for surgery. It contains a certain amount of LED lens units, which are embedded in the ceiling and arranged around the air supply smallpox. The LED lens unit integrated with an LED light source and a free-form lens is required to produce a uniform circular illumination with a large tolerance to the change of lighting distance. To achieve such a dedicated lens, two free-form refractive surfaces, which are converted into two ordinary differential equations by the design method presented in this paper, are used to deflect the rays. The results show that the LED surgical lighting system can provide an excellent illumination environment for surgery, and, apparently, the laminar disturbance also can be relieved.

  10. Towards robotic heart surgery: introduction of autonomous procedures into an experimental surgical telemanipulator system.

    Science.gov (United States)

    Bauernschmitt, R; Schirmbeck, E U; Knoll, A; Mayer, H; Nagy, I; Wessel, N; Wildhirt, S M; Lange, R

    2005-09-01

    The introduction of telemanipulator systems into cardiac surgery enabled the heart surgeon to perform minimally invasive procedures with high precision and stereoscopic view. For further improvement and especially for inclusion of autonomous action sequences, implementation of force-feedback is necessary. The aim of our study was to provide a robotic scenario giving the surgeon an impression very similar to open procedures (high immersion) and to enable autonomous surgical knot tying with delicate suture material. In this experimental set-up the feasibility of autonomous surgical knot tying is demonstrated for the first time using stereoscopic view and force feedback. Copyright 2005 John Wiley & Sons, Ltd.

  11. The use of a surgical incision management system on vascular surgery incisions: a pilot study.

    Science.gov (United States)

    Weir, Gregory

    2014-06-01

    Health care-associated infections in hospitals, including surgical site infections, contribute significantly to morbidity as well as mortality. Surgical incision management (SIM) using negative pressure wound therapy (Prevena™ Incision Management System, Kinetic Concepts, Inc., San Antonio, TX, USA) is designed to cover and protect closed surgical incisions from external factors including infectious sources and local trauma, while negative pressure removes fluid and infectious material from the surgical incision. A prospective case-control study assessed wound complications in patients undergoing vascular bypass procedures, where both femoral areas were incised to gain access to the femoral arteries. SIM was placed on one femoral area while a standard postoperative wound dressing was placed on the contralateral femoral area. Eight patients were included in this pilot study. All of them required bilateral femoral artery access. During the follow-up period patients were monitored for wound complications. All wound complications requiring surgical intervention were considered significant. No significant wound complications occurred in wounds treated with SIM, compared with three significant complications in control wounds. These preliminary data would suggest a potential reduction in wound complications and no observed increase in haemorrhage in high-risk patients with severe co-morbidities undergoing vascular surgery.

  12. Risk factors for retained surgical items: a meta-analysis and proposed risk stratification system.

    Science.gov (United States)

    Moffatt-Bruce, Susan D; Cook, Charles H; Steinberg, Steven M; Stawicki, Stanislaw P

    2014-08-01

    Retained surgical items (RSI) are designated as completely preventable "never events". Despite numerous case reports, clinical series, and expert opinions few studies provide quantitative insight into RSI risk factors and their relative contributions to the overall RSI risk profile. Existing case-control studies lack the ability to reliably detect clinically important differences within the long list of proposed risks. This meta-analysis examines the best available data for RSI risk factors, seeking to provide a clinically relevant risk stratification system. Nineteen candidate studies were considered for this meta-analysis. Three retrospective, case-control studies of RSI-related risk factors contained suitable group comparisons between patients with and without RSI, thus qualifying for further analysis. Comprehensive Meta-Analysis 2.0 (BioStat, Inc, Englewood, NJ) software was used to analyze the following "common factor" variables compiled from the above studies: body-mass index, emergency procedure, estimated operative blood loss >500 mL, incorrect surgical count, lack of surgical count, >1 subprocedure, >1 surgical team, nursing staff shift change, operation "afterhours" (i.e., between 5 PM and 7 AM), operative time, trainee presence, and unexpected intraoperative factors. We further stratified resulting RSI risk factors into low, intermediate, and high risk. Despite the fact that only between three and six risk factors were associated with increased RSI risk across the three studies, our analysis of pooled data demonstrates that seven risk factors are significantly associated with increased RSI risk. Variables found to elevate the RSI risk include intraoperative blood loss >500 mL (odds ratio [OR] 1.6); duration of operation (OR 1.7); >1 subprocedure (OR 2.1); lack of surgical counts (OR 2.5); >1 surgical team (OR 3.0); unexpected intraoperative factors (OR 3.4); and incorrect surgical count (OR 6.1). Changes in nursing staff, emergency surgery, body

  13. Prototyping a Hybrid Cooperative and Tele-robotic Surgical System for Retinal Microsurgery

    Science.gov (United States)

    Balicki, Marcin; Xia, Tian; Jung, Min Yang; Deguet, Anton; Vagvolgyi, Balazs; Kazanzides, Peter; Taylor, Russell

    2013-01-01

    This paper presents the design of a tele-robotic microsurgical platform designed for development of cooperative and tele-operative control schemes, sensor based smart instruments, user interfaces and new surgical techniques with eye surgery as the driving application. The system is built using the distributed component-based cisst libraries and the Surgical Assistant Workstation framework. It includes a cooperatively controlled EyeRobot2, a da Vinci Master manipulator, and a remote stereo visualization system. We use constrained optimization based virtual fixture control to provide Virtual Remote-Center-of-Motion (vRCM) and haptic feedback. Such system can be used in a hybrid setup, combining local cooperative control with remote tele-operation, where an experienced surgeon can provide hand-over-hand tutoring to a novice user. In another scheme, the system can provide haptic feedback based on virtual fixtures constructed from real-time force and proximity sensor information. PMID:24398557

  14. Effect of Ultrasound on the Compaction of Ibuprofen/Isomalt Systems

    OpenAIRE

    2009-01-01

    Six mixtures, containing 10, 20 and 30% w/w ibuprofen and isomalt, were compacted by a traditional or ultrasound-assisted machine and analysed by means of thermal (DSC and TGA) and micro-spectrometry (Raman and FT-IR) techniques. Ultrasound discharge causes melting of ibuprofen powder, transforming into a paste that could not assume the shape of a tablet; when in mixture with isomalt, thermal events, occurring during ultrasound compaction, change the appearance of the particles formed by mill...

  15. [Analysis of key vision position technologies in robot assisted surgical system for total knee replacement].

    Science.gov (United States)

    Zhao, Zijian; Liu, Yuncai; Wu, Xiaojuan; Liu, Hongjian

    2008-02-01

    Robot assisted surgery is becoming a widely popular technology and is now entering the total knee replacement. The development of total knee replacement and the operation system structure are introduced in this paper. The vision position technology and the related calibration technology, which are very important, are also analyzed. The experiments of error analysis in our WATO system demonstrate that the position and related calibration technologies have a high precision and can satisfy surgical requirement.

  16. Features of haptic and tactile feedback in TORS-a comparison of available surgical systems.

    Science.gov (United States)

    Friedrich, Daniel T; Dürselen, L; Mayer, B; Hacker, S; Schall, F; Hahn, J; Hoffmann, T K; Schuler, P J; Greve, J

    2017-05-03

    Sustained interest and an increase of possible indications endorse the role of robot-assisted surgery of the head and neck region. However, broad clinical application is impeded by substantial extra cost, time exposure and a supposed deficit of haptic and tactile feedback. The role of haptic feedback has barely been examined in this context, and literature provides only limited objective validation. This point of criticism applies to all commercially available systems. We created an experimental setup to evaluate, quantify and compare the performance of surgical systems. The daVinci system (Intuitive Surgical), the Flex system (Medrobotics) and standard rigid instruments (23 cm laryngoscopic grasper, Karl Storz) were compared with the human hand by head and neck surgeons (n = 15), performing a variety of surgical tasks. Specific samples with different rigidity were sorted with all devices, and the resulting orders were analyzed by permutation analysis, indicating differences in precision and accuracy of haptic and tactile feedback. The human hand was superior in all trials, acting as reference modality. The flexible instruments of the Flex system performed better than the electro-mechanically decoupled instruments of the daVinci system for the majority of measures recorded, suggesting a benefit in terms of haptic and tactile feedback in this context. While not all aspects of haptic and tactile feedback were accessible, this first objective comparison endorses the inferiority of robot-assisted surgery in terms of haptic and tactile feedback, compared to the human sense or standard surgical tools. Furthermore, the immediate force transmission of the Flex system seems to be superior to the electro-mechanical transformation of the daVinci system, indicating an advantage in terms of haptic and tactile feedback in immediate comparison. This study is providing a basis for further experiments and the development of robotic surgery towards an implementation in clinical

  17. MR guided focused ultrasound: technical acceptance measures for a clinical system

    Energy Technology Data Exchange (ETDEWEB)

    Gorny, K R; Hangiandreou, N J; Hesley, G K; Gostout, B S; McGee, K P; Felmlee, J P [Department of Radiology, Mayo Clinic, Rochester, MN 55905 (United States)

    2006-06-21

    Magnetic resonance (MR) guided focused ultrasound (MRgFUS) is a hybrid technique which offers efficient and safe focused ultrasound (FUS) treatments of uterine fibroids under MR guidance and monitoring. As a therapy device, MRgFUS requires systematic testing over a wide range of operational parameters prior to use in the clinical environment. We present technical acceptance tests and data for the first clinical MRgFUS system, ExAblate (registered) 2000 (InSightec Inc., Haifa, Israel), that has been FDA approved for treating uterine fibroids. These tests characterize MRgFUS by employing MR temperature measurements in tissue mimicking phantoms. The coronal scan plane is empirically demonstrated to be most reliable for measuring temperature elevations resulting from high intensity ultrasound (US) pulses ('sonications') and shows high sensitivity to changes in sonication parameters. Temperatures measured in the coronal plane were used as a measure of US energy deposited within the focal spot for a range of sonication parameters used in clinical treatments: spot type, spot length, output power, sonication duration, US frequency, and depth of sonication. In addition, MR images acquired during sonications were used to measure effective diameters and lengths of available sonication spot types and lengths. At a constant 60 W output power, the effective spot type diameters were measured to vary between 4.7 {+-} 0.3 mm and 6.6 {+-} 0.4 mm; treatment temperatures were found to decrease with increasing spot diameter. Prescribing different spot lengths was found to have no effect on the measured length or on measured temperatures. Tests of MRgFUS positioning accuracy determined errors in the direction parallel to the propagation of the US beam to be significantly greater than those in the perpendicular direction; most sonication spots were erroneously positioned towards the FUS transducer. The tests reported here have been demonstrated to be sufficiently sensitive to

  18. Ultrasound skin tightening.

    Science.gov (United States)

    Minkis, Kira; Alam, Murad

    2014-01-01

    Ultrasound skin tightening is a noninvasive, nonablative method that allows for energy deposition into the deep dermal and subcutaneous tissue while avoiding epidermal heating. Ultrasound coagulation is confined to arrays of 1-mm(3) zones that include the superficial musculoaponeurotic system and connective tissue. This technology gained approval from the Food and Drug Administration as the first energy-based skin "lifting" device, specifically for lifting lax tissue on the neck, submentum, and eyebrows. Ultrasound has the unique advantage of direct visualization of treated structures during treatment. Ultrasound is a safe and efficacious treatment for mild skin tightening and lifting.

  19. [A surgical navigation system based on C-arm fluoroscopy images].

    Science.gov (United States)

    Qian, Liwei; Yan, Shijun; Xia, Qing; Wang, Chengtao

    2009-10-01

    A surgical navigation system based on X-rays of C-arm with a calibration target has been studied and developed. Extracting images of markers in the two templates on the calibration target, the system is able to establish the relationship between different markers coordinates in different coordinate systems using the algorithm based on the layout of specific markers. The correction of X-ray image distortion and C-arm camera calibration are performed using the images of calibration target as bases. After the parameters of the C-arm projection model being determined, an X-ray image of surgical site will be acquired preoperatively; the surgical instruments will be tracked by the optical position system, and then virtual projections of instruments can be formed on preoperative images. Surgeons will perform operations with the guidance of the system. The C-arm can be used less frequently and the X-ray radiation can be reduced. Cadaveric spine specimen experiments and error analysis have underpinned the clinical feasibility of the system.

  20. 3D interactive surgical visualization system using mobile spatial information acquisition and autostereoscopic display.

    Science.gov (United States)

    Fan, Zhencheng; Weng, Yitong; Chen, Guowen; Liao, Hongen

    2017-07-01

    Three-dimensional (3D) visualization of preoperative and intraoperative medical information becomes more and more important in minimally invasive surgery. We develop a 3D interactive surgical visualization system using mobile spatial information acquisition and autostereoscopic display for surgeons to observe surgical target intuitively. The spatial information of regions of interest (ROIs) is captured by the mobile device and transferred to a server for further image processing. Triangular patches of intraoperative data with texture are calculated with a dimension-reduced triangulation algorithm and a projection-weighted mapping algorithm. A point cloud selection-based warm-start iterative closest point (ICP) algorithm is also developed for fusion of the reconstructed 3D intraoperative image and the preoperative image. The fusion images are rendered for 3D autostereoscopic display using integral videography (IV) technology. Moreover, 3D visualization of medical image corresponding to observer's viewing direction is updated automatically using mutual information registration method. Experimental results show that the spatial position error between the IV-based 3D autostereoscopic fusion image and the actual object was 0.38±0.92mm (n=5). The system can be utilized in telemedicine, operating education, surgical planning, navigation, etc. to acquire spatial information conveniently and display surgical information intuitively. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. A Portable Shoulder-Mounted Camera System for Surgical Education in Spine Surgery.

    Science.gov (United States)

    Pham, Martin H; Ohiorhenuan, Ifije E; Patel, Neil N; Jakoi, Andre M; Hsieh, Patrick C; Acosta, Frank L; Wang, Jeffrey C; Liu, John C

    2017-02-07

    The past several years have demonstrated an increased recognition of operative videos as an important adjunct for resident education. Currently lacking, however, are effective methods to record video for the purposes of illustrating the techniques of minimally invasive (MIS) and complex spine surgery. We describe here our experiences developing and using a shoulder-mounted camera system for recording surgical video. Our requirements for an effective camera system included wireless portability to allow for movement around the operating room, camera mount location for comfort and loupes/headlight usage, battery life for long operative days, and sterile control of on/off recording. With this in mind, we created a shoulder-mounted camera system utilizing a GoPro™ HERO3+, its Smart Remote (GoPro, Inc., San Mateo, California), a high-capacity external battery pack, and a commercially available shoulder-mount harness. This shoulder-mounted system was more comfortable to wear for long periods of time in comparison to existing head-mounted and loupe-mounted systems. Without requiring any wired connections, the surgeon was free to move around the room as needed. Over the past several years, we have recorded numerous MIS and complex spine surgeries for the purposes of surgical video creation for resident education. Surgical videos serve as a platform to distribute important operative nuances in rich multimedia. Effective and practical camera system setups are needed to encourage the continued creation of videos to illustrate the surgical maneuvers in minimally invasive and complex spinal surgery. We describe here a novel portable shoulder-mounted camera system setup specifically designed to be worn and used for long periods of time in the operating room.

  2. Real-time ultrasound-guided PCNL using a novel SonixGPS needle tracking system.

    Science.gov (United States)

    Li, Xiang; Long, Qingzhi; Chen, Xingfa; He, Dalin; Dalin, He; He, Hui

    2014-08-01

    SonixGPS is a successful ultrasound guidance position system. It helps to improve accuracy in performing complex puncture operations. This study firstly used SonixGPS to perform kidney calyx access in PCNL to investigate its effectiveness and safety. This was a prospectively randomized controlled study performed from September 2011 to October 2012. A total of 97 patients were prospectively randomized into two groups using random number generated from SAS software. 47 Patients were enrolled in conventional ultrasound-guided (US-guided) group and 50 patients were classified into SonixGPS-guided group. Nine patients were lost during follow-up. Hence, a total of 88 patients were qualified and analyzed. Preoperative examinations included urine analysis, urine culture, kidney function, coagulation profile and routine analysis of blood. Ultrasonography was used to evaluate the degree of hydronephrosis. The intraoperative findings, including blood loss, operating time, time to successful puncture, the number of attempts for successful puncture and hospital stay were recorded. The stone clearance rate and complications were analyzed. The present study showed no significant difference between the two groups in terms of demographic data, preoperative markers, stone clearance rate and the stone composition. However, the time to successful puncture, the number of trials for successful puncture, operating time and hospital length of stay were significantly decreased in the SonixGPS-guided group. Furthermore, the hemoglobin decrease was also obviously lower in the SonixGPS group than that in conventional US-guided group. SonixGPS needle tacking system guided PCNL is safe and effective in treating upper urinary tract stones. This novel technology makes puncturing more accuracy and can significantly decrease the incidence of relative hemorrhage and accelerate recovery.

  3. SVM-Based CAC System for B-Mode Kidney Ultrasound Images.

    Science.gov (United States)

    Subramanya, M B; Kumar, Vinod; Mukherjee, Shaktidev; Saini, Manju

    2015-08-01

    The present study proposes a computer-aided classification (CAC) system for three kidney classes, viz. normal, medical renal disease (MRD) and cyst using B-mode ultrasound images. Thirty-five B-mode kidney ultrasound images consisting of 11 normal images, 8 MRD images and 16 cyst images have been used. Regions of interest (ROIs) have been marked by the radiologist from the parenchyma region of the kidney in case of normal and MRD cases and from regions inside lesions for cyst cases. To evaluate the contribution of texture features extracted from de-speckled images for the classification task, original images have been pre-processed by eight de-speckling methods. Six categories of texture features are extracted. One-against-one multi-class support vector machine (SVM) classifier has been used for the present work. Based on overall classification accuracy (OCA), features from ROIs of original images are concatenated with the features from ROIs of pre-processed images. On the basis of OCA, few feature sets are considered for feature selection. Differential evolution feature selection (DEFS) has been used to select optimal features for the classification task. DEFS process is repeated 30 times to obtain 30 subsets. Run-length matrix features from ROIs of images pre-processed by Lee's sigma concatenated with that of enhanced Lee method have resulted in an average accuracy (in %) and standard deviation of 86.3 ± 1.6. The results obtained in the study indicate that the performance of the proposed CAC system is promising, and it can be used by the radiologists in routine clinical practice for the classification of renal diseases.

  4. 3D ultrasound system to investigate intraventricular hemorrhage in preterm neonates

    Science.gov (United States)

    Kishimoto, J.; de Ribaupierre, S.; Lee, D. S. C.; Mehta, R.; St. Lawrence, K.; Fenster, A.

    2013-11-01

    Intraventricular hemorrhage (IVH) is a common disorder among preterm neonates that is routinely diagnosed and monitored by 2D cranial ultrasound (US). The cerebral ventricles of patients with IVH often have a period of ventricular dilation (ventriculomegaly). This initial increase in ventricle size can either spontaneously resolve, which often shows clinically as a period of stabilization in ventricle size and eventual decline back towards a more normal size, or progressive ventricular dilation that does not stabilize and which may require interventional therapy to reduce symptoms relating to increased intracranial pressure. To improve the characterization of ventricle dilation, we developed a 3D US imaging system that can be used with a conventional clinical US scanner to image the ventricular system of preterm neonates at risk of ventriculomegaly. A motorized transducer housing was designed specifically for hand-held use inside an incubator using a transducer commonly used for cranial 2D US scans. This system was validated using geometric phantoms, US/MRI compatible ventricle volume phantoms, and patient images to determine 3D reconstruction accuracy and inter- and intra-observer volume estimation variability. 3D US geometric reconstruction was found to be accurate with an error of 0.05) for the measured ventricle volumes between observers. This 3D US system can reliably produce 3D US images of the neonatal ventricular system. There is the potential to use this system to monitor the progression of ventriculomegaly over time in patients with IVH.

  5. Single-use surgical clothing system for reduction of airborne bacteria in the operating room.

    Science.gov (United States)

    Tammelin, A; Ljungqvist, B; Reinmüller, B

    2013-07-01

    It is desirable to maintain a low bacterial count in the operating room air to prevent surgical site infection. This can be achieved by ventilation or by all staff in the operating room wearing clothes made from low-permeable material (i.e. clean air suits). We investigated whether there was a difference in protective efficacy between a single-use clothing system made of polypropylene and a reusable clothing system made of a mixed material (cotton/polyester) by testing both in a dispersal chamber and during surgical procedures. Counts of colony-forming units (cfu)/m(3) air were significantly lower when using the single-use clothing system in both settings. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  6. Three-dimensional ultrasound image-guided robotic system for accurate microwave coagulation of malignant liver tumours.

    Science.gov (United States)

    Xu, Jing; Jia, Zhen-zhong; Song, Zhang-jun; Yang, Xiang-dong; Chen, Ken; Liang, Ping

    2010-09-01

    The further application of conventional ultrasound (US) image-guided microwave (MW) ablation of liver cancer is often limited by two-dimensional (2D) imaging, inaccurate needle placement and the resulting skill requirement. The three-dimensional (3D) image-guided robotic-assisted system provides an appealing alternative option, enabling the physician to perform consistent, accurate therapy with improved treatment effectiveness. Our robotic system is constructed by integrating an imaging module, a needle-driven robot, a MW thermal field simulation module, and surgical navigation software in a practical and user-friendly manner. The robot executes precise needle placement based on the 3D model reconstructed from freehand-tracked 2D B-scans. A qualitative slice guidance method for fine registration is introduced to reduce the placement error caused by target motion. By incorporating the 3D MW specific absorption rate (SAR) model into the heat transfer equation, the MW thermal field simulation module determines the MW power level and the coagulation time for improved ablation therapy. Two types of wrists are developed for the robot: a 'remote centre of motion' (RCM) wrist and a non-RCM wrist, which is preferred in real applications. The needle placement accuracies were < 3 mm for both wrists in the mechanical phantom experiment. The target accuracy for the robot with the RCM wrist was improved to 1.6 +/- 1.0 mm when real-time 2D US feedback was used in the artificial-tissue phantom experiment. By using the slice guidance method, the robot with the non-RCM wrist achieved accuracy of 1.8 +/- 0.9 mm in the ex vivo experiment; even target motion was introduced. In the thermal field experiment, a 5.6% relative mean error was observed between the experimental coagulated neurosis volume and the simulation result. The proposed robotic system holds promise to enhance the clinical performance of percutaneous MW ablation of malignant liver tumours. Copyright 2010 John Wiley

  7. Medical ultrasound imaging

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2007-01-01

    The paper gives an introduction to current medical ultrasound imaging systems. The basics of anatomic and blood flow imaging are described. The properties of medical ultrasound and its focusing are described, and the various methods for two- and three-dimensional imaging of the human anatomy...

  8. New real-time MR image-guided surgical robotic system for minimally invasive precision surgery

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, M.; Yasunaga, T.; Konishi, K. [Kyushu University, Department of Advanced Medical Initiatives, Faculty of Medical Sciences, Fukuoka (Japan); Tanoue, K.; Ieiri, S. [Kyushu University Hospital, Department of Advanced Medicine and Innovative Technology, Fukuoka (Japan); Kishi, K. [Hitachi Ltd, Mechanical Engineering Research Laboratory, Hitachinaka-Shi, Ibaraki (Japan); Nakamoto, H. [Hitachi Medical Corporation, Application Development Office, Kashiwa-Shi, Chiba (Japan); Ikeda, D. [Mizuho Ikakogyo Co. Ltd, Tokyo (Japan); Sakuma, I. [The University of Tokyo, Graduate School of Engineering, Bunkyo-Ku, Tokyo (Japan); Fujie, M. [Waseda University, Graduate School of Science and Engineering, Shinjuku-Ku, Tokyo (Japan); Dohi, T. [The University of Tokyo, Graduate School of Information Science and Technology, Bunkyo-Ku, Tokyo (Japan)

    2008-04-15

    To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D navigation and 2-D ISC images, as well as the MR-compatible laparoscope. The ISC image was updated every 4 s; no artifact was detected. A newly developed MR image-guided surgical robotic system is feasible for an operator to perform safe and precise minimally invasive procedures. (orig.)

  9. Adaptive field-of-view imaging for efficient receive beamforming in medical ultrasound imaging systems.

    Science.gov (United States)

    Agarwal, Anup; Yoo, Yang Mo; Schneider, Fabio Kurt; Kim, Yongmin

    2008-09-01

    Quadrature demodulation-based phase rotation beamforming (QD-PRBF) is commonly used to support dynamic receive focusing in medical ultrasound systems. However, it is computationally demanding since it requires two demodulation filters for each receive channel. To reduce the computational requirements of QD-PRBF, we have previously developed two-stage demodulation (TSD), which reduces the number of lowpass filters by performing demodulation filtering on summation signals. However, it suffers from image quality degradation due to aliasing at lower beamforming frequencies. To improve the performance of TSD-PRBF with reduced number of beamforming points, we propose a new adaptive field-of-view (AFOV) imaging method. In AFOV imaging, the beamforming frequency is adjusted depending on displayed FOV size and the center frequency of received signals. To study its impact on image quality, simulation was conducted using Field II, phantom data were acquired from a commercial ultrasound machine, and the image quality was quantified using spatial (i.e., axial and lateral) and contrast resolution. The developed beamformer (i.e., TSD-AFOV-PRBF) with 1024 beamforming points provided comparable image resolution to QD-PRBF for typical FOV sizes (e.g., 4.6% and 1.3% degradation in contrast resolution for 160 mm and 112 mm, respectively for a 3.5 MHz transducer). Furthermore, it reduced the number of operations by 86.8% compared to QD-PRBF. These results indicate that the developed TSD-AFOV-PRBF can lower the computational requirement for receive beamforming without significant image quality degradation.

  10. Delineation of atherosclerotic plaque using subharmonic imaging filtering techniques and a commercial intravascular ultrasound system.

    Science.gov (United States)

    Sridharan, Anush; Eisenbrey, John R; Machado, Priscilla; deMuinck, Ebo D; Doyley, Marvin M; Forsberg, Flemming

    2013-01-01

    The ability to delineate atherosclerotic plaque from the surrounding tissue using custom-developed subharmonic imaging (SHI) digital filtering techniques was investigated in vivo using a commercially available system. Atherosclerosis was induced in the aorta of two Watanabe Heritable Hyperlipidemic rabbits following which injections of an ultrasound contrast agent (UCA) Definity (Lantheus Medical Imaging, N Billerica, Massachusetts) were administered. Imaging was performed using a Galaxy intravascular ultrasound (IVUS) scanner (Boston Scientific, Natick, Massachusetts) equipped with an Atlantis® SR Pro Imaging Catheter (Boston Scientific). Four preliminary band-pass filters were designed to isolate the subharmonic signal (from surrounding tissue) and applied to the radio-frequency (RF) data. Preliminary filter performances were compared in terms of vessel-tissue contrast-to-tissue ratio (CTR) and visual examination. Based on preliminary results, a subharmonic adaptive filter and a stopband (SB) filter were designed and applied to the RF data. Images were classified as fundamental, SHI, and SB. Four readers performed qualitative analysis of 168 randomly selected images (across all three imaging modes). The images were scored for overall image quality, image noise, plaque visualization, and vessel lumen visualization. A Wilcoxon signed-rank test was used to compare the scores followed by intraclass correlation (ICC) evaluation. Quantitative analysis was performed by calculating the CTRs for the vessel-to-plaque and vessel-to-tissue (compared using a paired student's t test). Qualitative analysis showed SHI and SB to have significantly less image noise relative to the fundamental mode (p < 0.001). Fundamental mode scored significantly higher than SHI and SB for the remaining three categories. ICC showed mixed results among reader evaluation for delineation of plaque. However, quantitatively, SHI produced the best vessel-plaque CTR.

  11. Ultrasound lung comets: new echographic sign of lung interstitial fibrosis in systemic sclerosis

    Directory of Open Access Journals (Sweden)

    C. Giacomelli

    2011-09-01

    Full Text Available Objective: Interstitial lung disease (ILD and pulmonary arterial hypertension (PAH are common complications of systemic sclerosis (SSc. Echocardiography evaluates PAH, and chest sonography detects even mild ILC as ultrasound lung comets (ULC, i.e. multiple comet-tails fanning out from the lung surface and originating from subpleural interlobular septa thickened by fibrosis. Aim: to assess ILaD and PAH by integrated cardiac and chest ultrasound in SSc. Methods: We enrolled 30 consecutive SSc patients (age= 54±13 years, 23 females in the Rheumatology Clinic of Pisa University. In all, we assessed systolic pulmonary arterial pressure (SPAP, from maximal velocity of tricuspid regurgitation flow, and ULC score with chest sonography (summing the number of ULC from each scanning space of anterior and posterior right and left chest, from second to fifth intercostal space. All patients underwent plasma assay for anti-topoisomerase antibodies (anti-Scl70, and antiicentromere associated with development of pulmonary involvement. Twenty-eight patients also underwent high resolution computed tomography, HRCT (from 0= no fibrosis to 3= honey combing. Results: ULC number - but not SPAP - was correlated to HRCT fibrosis and presence Scl-70 antibodies. ULC number was similar in localized or diffuse forms (16±20 vs 21±19, p=ns and was unrelated to SPAP (r=0.216, p=ns. Conclusions: Chest sonography assessment and ULC allow a complete, simple, radiation-free characterization of interstitial lung involvement in SSc - all in one setting and with the same instrument, same transducer and the same sonographer. In particular, ULC number is associated with HRCT evidence of lung fibrosis and presence of Scl-70 antibodies.

  12. The radius surgical system - a new device for complex minimally invasive procedures in urology?

    Science.gov (United States)

    Frede, Thomas; Hammady, Ahmed; Klein, Jan; Teber, Dogu; Inaki, Noriyuki; Waseda, Masahiro; Buess, Gerhard; Rassweiler, Jens

    2007-04-01

    Complex laparoscopic procedures in urology are technically demanding with an extended learning curve. Robotic systems add significant cost to laparoscopic procedures. We therefore evaluated the use of the Radius Surgical System (RSS), a mechanical manipulator, for complex laparoscopic cases in urology. The RSS (Tuebingen Scientific) consists of two hand-guided surgical manipulators and provides a deflectable and rotatable tip allowing six degrees of freedom. We evaluated the system by using a series of standardized models in the pelvitrainer. We analyzed the effectiveness of the system and the learning curve. We then evaluated the system in the clinical setting during laparoscopic radical prostatectomy. Surgeons with experience on the RSS were compared to surgeons without previous experience on the system. We identified a learning curve in those participants without experience on the system only when performing complete anastomoses in the pelvitrainer. However, this learning curve included less than 10 anastomoses. The first clinical experiences during laparoscopic extraperitoneal radical prostatectomy (n=10) are promising. All anastomoses were patent on routine (X-ray) examination 8 days after surgery. The RSS system is easy to use and we identified a very short learning curve. We now optimize the system for use in urology. This device may facilitate complex laparoscopic procedures without the use of costly robotic systems and should be further evaluated in the experimental and clinical setting.

  13. MPEG compression of ultrasound RF channel data for a real-time software-based imaging system.

    Science.gov (United States)

    Cheng, Po-Wen; Shen, Che-Chou; Li, Pai-Chi

    2012-07-01

    Using software for beamforming in ultrasound systems provides high flexibility, and the large number of computations required in a software-based system can be performed in real time on a PC. However, the very large data transfer rate required from the ultrasound front-end to the PC host for real-time operation is a bottleneck which cannot be overcome without appropriate compression. Previous studies have examined JPEG compression of ultrasound RF channel data, but the schemes do not exploit temporal redundancy between adjacent frames. This study utilized MPEG technology to process the ultrasound RF data to increase the compression efficiency. Our results indicate that MPEG compression generally provides a better compression ratio than does JPEG compression. As an example, the compression ratio of MPEG compression in an 8-bit channel A/D data under 5 μm interframe displacement is smaller than 0.13, thus allowing real-time data transfer requirements to be met. Moreover, the compression efficiency for motions in different directions is shown to be highly dependent on the frame-to-frame correlation.

  14. Open-source, small-animal magnetic resonance-guided focused ultrasound system.

    Science.gov (United States)

    Poorman, Megan E; Chaplin, Vandiver L; Wilkens, Ken; Dockery, Mary D; Giorgio, Todd D; Grissom, William A; Caskey, Charles F

    2016-01-01

    MR-guided focused ultrasound or high-intensity focused ultrasound (MRgFUS/MRgHIFU) is a non-invasive therapeutic modality with many potential applications in areas such as cancer therapy, drug delivery, and blood-brain barrier opening. However, the large financial costs involved in developing preclinical MRgFUS systems represent a barrier to research groups interested in developing new techniques and applications. We aim to mitigate these challenges by detailing a validated, open-source preclinical MRgFUS system capable of delivering thermal and mechanical FUS in a quantifiable and repeatable manner under real-time MRI guidance. A hardware and software package was developed that includes closed-loop feedback controlled thermometry code and CAD drawings for a therapy table designed for a preclinical MRI scanner. For thermal treatments, the modular software uses a proportional integral derivative controller to maintain a precise focal temperature rise in the target given input from MR phase images obtained concurrently. The software computes the required voltage output and transmits it to a FUS transducer that is embedded in the delivery table within the magnet bore. The delivery table holds the FUS transducer, a small animal and its monitoring equipment, and a transmit/receive RF coil. The transducer is coupled to the animal via a water bath and is translatable in two dimensions from outside the magnet. The transducer is driven by a waveform generator and amplifier controlled by real-time software in Matlab. MR acoustic radiation force imaging is also implemented to confirm the position of the focus for mechanical and thermal treatments. The system was validated in tissue-mimicking phantoms and in vivo during murine tumor hyperthermia treatments. Sonications were successfully controlled over a range of temperatures and thermal doses for up to 20 min with minimal temperature overshoot. MR thermometry was validated with an optical temperature probe, and focus

  15. Dimensional optimization of a minimally invasive surgical robot system based on NSGA-II algorithm

    OpenAIRE

    Wei Wang; Weidong Wang; Wei Dong; Hongjian Yu; Zhiyuan Yan; Zhijiang Du

    2015-01-01

    Based on the proposed end-effector structure of a laparoscopic minimally invasive surgical manipulator, a dimensional optimization method is investigated to enlarge the motion range of the mechanical arm in the specific target area and reduce the collision among the mechanical arms simultaneously. Both the length of the kinematics links and the overall size of the integrated system are considered in the optimization process. The NSGA-II algorithm oriented to the multi-objective optimization i...

  16. CMOS Ultrasound Transceiver Chip for High-Resolution Ultrasonic Imaging Systems.

    Science.gov (United States)

    Insoo Kim; Hyunsoo Kim; Griggio, F; Tutwiler, R L; Jackson, T N; Trolier-McKinstry, S; Kyusun Choi

    2009-10-01

    The proposed CMOS ultrasound transceiver chip will enable the development of portable high resolution, high-frequency ultrasonic imaging systems. The transceiver chip is designed for close-coupled MEMS transducer arrays which operate with a 3.3-V power supply. In addition, a transmit digital beamforming system architecture is supported in this work. A prototype chip containing 16 receive and transmit channels with preamplifiers, time-gain compensation amplifiers, a multiplexed analog-to-digital converter with 3 kB of on-chip SRAM, and 50-MHz resolution time delayed excitation pulse generators has been fabricated. By utilizing a shared A/D converter architecture, the number of A/D converter and SRAM is cut down to one, unlike typical digital beamforming systems which need 16 A/D converters for 16 receive channels. The chip was fabricated in a 0.35-mum standard CMOS process. The chip size is 10 mm(2), and its average power consumption in receive mode is approximately 270 mW with a 3.3-V power supply. The transceiver chip specifications and designs are described, as well as measured results of each transceiver component and initial pulse-echo experimental results are presented.

  17. Local Gene Delivery System by Bubble Liposomes and Ultrasound Exposure into Joint Synovium

    Directory of Open Access Journals (Sweden)

    Yoichi Negishi

    2011-01-01

    Full Text Available Recently, we have developed novel polyethylene glycol modified liposomes (bubble liposomes; BL entrapping an ultrasound (US imaging gas, which can work as a gene delivery tool with US exposure. In this study, we investigated the usefulness of US-mediated gene transfer systems with BL into synoviocytes in vitro and joint synovium in vivo. Highly efficient gene transfer could be achieved in the cultured primary synoviocytes transfected with the combination of BL and US exposure, compared to treatment with plasmid DNA (pDNA alone, pDNA plus BL, or pDNA plus US. When BL was injected into the knee joints of mice, and US exposure was applied transcutaneously to the injection site, highly efficient gene expression could be observed in the knee joint transfected with the combination of BL and US exposure, compared to treatment with pDNA alone, pDNA plus BL, or pDNA plus US. The localized and prolonged gene expression was also shown by an in vivo luciferase imaging system. Thus, this local gene delivery system into joint synovium using the combination of BL and US exposure may be an effective means for gene therapy in joint disorders.

  18. 3D optical imagery for motion compensation in a limb ultrasound system

    Science.gov (United States)

    Ranger, Bryan J.; Feigin, Micha; Zhang, Xiang; Mireault, Al; Raskar, Ramesh; Herr, Hugh M.; Anthony, Brian W.

    2016-04-01

    Conventional processes for prosthetic socket fabrication are heavily subjective, often resulting in an interface to the human body that is neither comfortable nor completely functional. With nearly 100% of amputees reporting that they experience discomfort with the wearing of their prosthetic limb, designing an effective interface to the body can significantly affect quality of life and future health outcomes. Active research in medical imaging and biomechanical tissue modeling of residual limbs has led to significant advances in computer aided prosthetic socket design, demonstrating an interest in moving toward more quantifiable processes that are still patient-specific. In our work, medical ultrasonography is being pursued to acquire data that may quantify and improve the design process and fabrication of prosthetic sockets while greatly reducing cost compared to an MRI-based framework. This paper presents a prototype limb imaging system that uses a medical ultrasound probe, mounted to a mechanical positioning system and submerged in a water bath. The limb imaging is combined with three-dimensional optical imaging for motion compensation. Images are collected circumferentially around the limb and combined into cross-sectional axial image slices, resulting in a compound image that shows tissue distributions and anatomical boundaries similar to magnetic resonance imaging. In this paper we provide a progress update on our system development, along with preliminary results as we move toward full volumetric imaging of residual limbs for prosthetic socket design. This demonstrates a novel multi-modal approach to residual limb imaging.

  19. Reliability of an Integrated Ultrasound and Stereophotogrammetric System for Lower Limb Anatomical Characterisation

    Directory of Open Access Journals (Sweden)

    Frederick Greatrex

    2017-01-01

    Full Text Available Background. Lower extremity analysis for preoperative total knee and hip arthroplasty routines can increase surgery success rate and hence reduce associated costs. Current tools are limited by being invasive, limited to supine analysis, or too expensive. This study aimed to propose and validate a device, OrthoPilot®, based on the combined use of a stereophotogrammetric and ultrasound system which can in vivo and noninvasively measure varus/valgus, flexion/extension, femur and tibia torsion, and femur and tibia lengths. Methods. A phantom was measured by four operators to determine the resolution of the system. Interoperator variability was measured on three operators who measured the above six variables on both legs of three subjects in standing and supine positions. Intraoperator variability was assessed on data from three repeats from 9 subjects (18 legs. Results. All 6 variables were reliably detected on a phantom, with a resolution of 1 mm and 0.5°. Inter- and intraoperator consistency was observed for varus/valgus, flexion/extension, and length measurements on the healthy subjects in standing and supine positions (all ICC > 0.93. For torsion measurements, there was a considerable variation. Conclusion. The proposed system, when used on healthy subjects, allowed reliable measurements of key parameters for preoperative procedures in both supine and standing positions. Accuracy testing and further validation on patient populations will be the next step toward its clinical adoption.

  20. Load evaluation of the da Vinci surgical system for transoral robotic surgery.

    Science.gov (United States)

    Fujiwara, Kazunori; Fukuhara, Takahiro; Niimi, Koji; Sato, Takahiro; Kitano, Hiroya

    2015-12-01

    Transoral robotic surgery, performed with the da Vinci surgical system (da Vinci), is a surgical approach for benign and malignant lesions of the oral cavity and laryngopharynx. It provides several unique advantages, which include a 3-dimensional magnified view and ability to see and work around curves or angles. However, the current da Vinci surgical system does not provide haptic feedback. This is problematic because the potential risks specific to the transoral use of the da Vinci include tooth injury, mucosal laceration, ocular injury and mandibular fracture. To assess the potential for intraoperative injuries, we measured the load of the endoscope and the instrument of the da Vinci Si surgical system. We pressed the endoscope and instrument of the da Vinci Si against Load cell six times each and measured the dynamic load and the time-to-maximum load. We also struck the da Vinci Si endoscope and instrument against the Load cell six times each and measured the impact load. The maximum dynamic load was 7.27 ± 1.31 kg for the endoscope and 1.90 ± 0.72 for the instrument. The corresponding time-to-maximum loads were 1.72 ± 0.22 and 1.29 ± 0.34 s, but the impact loads were significantly lower than the dynamic load. It remains possible that a major load is exerted on adjacent structures by continuous contact with the endoscope and instrument of da Vinci Si. However, there is a minor delay in reaching the maximum load. Careful monitoring by an on-site assistant may, therefore, help prevent contiguous injury.

  1. Application of Ultrasound in a Closed System: Optimum Condition for Antioxidants Extraction of Blackberry (Rubus fructicosus Residues

    Directory of Open Access Journals (Sweden)

    Quinatzin Y. Zafra-Rojas

    2016-07-01

    Full Text Available Blackberry processing generates up to 20% of residues composed mainly of peel, seeds and pulp that are abundant in flavonoids. The objective of this study was to optimize the ultrasound conditions, in a closed system, for antioxidants extraction, using the response surface methodology. Blackberry (Rubus fructicosus residues were analyzed for total phenolics, total anthocyanins, and antioxidant activity by ABTS and DPPH. The selected independent variables were ultrasound amplitude (X1: 80%–90% and extraction time (X2: 10–15 min, and results were compared with conventional extraction methods. The optimal conditions for antioxidants extraction were 91% amplitude for 15 min. The results for total phenolic content and anthocyanins and antioxidant activity by ABTS and DPPH were of 1201.23 mg gallic acid equivalent (GAE/100 g dry weight basis (dw; 379.12 mg/100 g·dw; 6318.98 µmol Trolox equivalent (TE/100 g·dw and 9617.22 µmol TE/100 g·dw, respectively. Compared to solvent extraction methods (water and ethanol, ultrasound achieved higher extraction of all compounds except for anthocyanins. The results obtained demonstrated that ultrasound is an alternative to improve extraction yield of antioxidants from fruit residues such as blackberry.

  2. In vivo photoacoustic and ultrasonic mapping of rat sentinel lymph nodes with a modified commercial ultrasound imaging system

    Science.gov (United States)

    Erpelding, Todd N.; Kim, Chulhong; Pramanik, Manojit; Guo, Zijian; Dean, John; Jankovic, Ladislav; Maslov, Konstantin; Wang, Lihong V.

    2010-02-01

    Sentinel lymph node biopsy (SLNB) has become the standard method for axillary staging in breast cancer patients, relying on invasive identification of sentinel lymph nodes (SLNs) following injection of blue dye and radioactive tracers. While SLNB achieves a low false negative rate (5-10%), it is an invasive procedure requiring ionizing radiation. As an alternative to SLNB, ultrasound-guided fine needle aspiration biopsy has been tested clinically. However, ultrasound alone is unable to accurately identify which lymph nodes are sentinel. Therefore, a non-ionizing and noninvasive detection method for accurate SLN mapping is needed. In this study, we successfully imaged methylene blue dye accumulation in vivo in rat axillary lymph nodes using a Phillips iU22 ultrasound imaging system adapted for photoacoustic imaging with an Nd:YAG pumped, tunable dye laser. Photoacoustic images of rat SLNs clearly identify methylene blue dye accumulation within minutes following intradermal dye injection and co-registered photoacoustic/ultrasound images illustrate lymph node position relative to surrounding anatomy. To investigate clinical translation, the imaging depth was extended up to 2.5 cm by adding chicken breast tissue on top of the rat skin surface. These results raise confidence that photoacoustic imaging can be used clinically for accurate, noninvasive SLN mapping.

  3. Microbubble-Assisted Ultrasound for Drug Delivery in the Brain and Central Nervous System.

    Science.gov (United States)

    Burgess, Alison; Hynynen, Kullervo

    2016-01-01

    The blood-brain barrier is a serious impediment to the delivery of pharmaceutical treatments for brain diseases, including cancer, neurodegenerative and neuropsychatric diseases. Focused ultrasound, when combined with microbubbles, has emerged as an effective method to transiently and locally open the blood-brain barrier to promote drug delivery to the brain. Focused ultrasound has been used to successfully deliver a wide variety of therapeutic agents to pre-clinical disease models. The requirement for clinical translation of focused ultrasound technology is considered.

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... as detailed as with the transrectal probe. An MRI of the pelvis may be obtained as an ... Benign Prostatic Hyperplasia (BPH) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ... other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning may be able to give a ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the procedure? In women, a pelvic ultrasound is most often performed to evaluate the: uterus cervix ovaries ... page How is the procedure performed? Transabdominal: For most ultrasound exams, you will be positioned lying face- ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... transducer into the body. Doppler ultrasound, a special application of ultrasound, measures the direction and speed of ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... menstrual problems Ultrasound exams also help identify: palpable masses such as ovarian cysts and uterine fibroids ovarian ... In children, pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... bladder seminal vesicles prostate Transrectal ultrasound, a special study usually done to provide detailed evaluation of the ... time to the procedure. If a Doppler ultrasound study is performed, you may actually hear pulse-like ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? In women, a pelvic ultrasound is most ... child's favorite channel. top of page What does the equipment look like? Ultrasound scanners consist of a ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal , endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... 3-D ultrasound or sonohysterography for patients with infertility. In this setting, three-dimensional ultrasound provides information ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... 20 minutes. top of page What will I experience during and after the procedure? Ultrasound exams in ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use ... procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ... pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic organs early ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Most ultrasound scanning is noninvasive (no needles or injections). Occasionally, an ultrasound exam may be temporarily uncomfortable, ... the following text box: Comment: E-mail: Area code: Phone no: Thank you! Images × Image Gallery Radiologist ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... investigation of the uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries ... abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with infertility. Three- ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... For most ultrasound exams, you will be positioned lying face-up on an examination table that can ... ovaries. Transvaginal ultrasound is usually performed with you lying on your back, possibly with your feet in ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... investigation of the uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries ... abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with infertility. In ...

  3. Endoscopic ultrasound

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/007646.htm Endoscopic ultrasound To use the sharing features on this page, please enable JavaScript. Endoscopic ultrasound is a type of imaging test. It is ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ... to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... chest. To obtain high-quality images, an ultrasound transducer – a plastic cylinder about the size of a ... or sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on the ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams also help identify: ... fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... time to the procedure. If a Doppler ultrasound study is performed, you may actually hear pulse-like ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Because ultrasound provides real-time images, it also can be used to guide procedures such as needle ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? In women, a pelvic ultrasound is most ... child's favorite channel. top of page What does the equipment look like? Ultrasound scanners consist of a ...

  13. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? Ultrasound exams in which the transducer ... a regular ultrasound imaging probe on the perineal skin of the patient, between the legs and behind ...

  14. The effect of a robot-assisted surgical system on the kinematics of user movements.

    Science.gov (United States)

    Nisky, Ilana; Hsieh, Michael H; Okamura, Allison M

    2013-01-01

    Teleoperated robot-assisted surgery (RAS) offers many advantages over traditional minimally invasive surgery. However, RAS has not yet realized its full potential, and it is not clear how to optimally train surgeons to use these systems. We hypothesize that the dynamics of the master manipulator impact the ability of users to make desired movements with the robot. We compared freehand and teleoperated movements of novices and experienced surgeons. To isolate the effects of dynamics from procedural knowledge, we chose simple movements rather than surgical tasks. We found statistically significant effects of teleoperation and user expertise in several aspects of motion, including target acquisition error, movement speed, and movement smoothness. Such quantitative assessment of human motor performance in RAS can impact the design of surgical robots, their control, and surgeon training methods, and eventually, improve patient outcomes.

  15. A compact mechatronic system for 3D ultrasound guided prostate interventions.

    Science.gov (United States)

    Bax, Jeffrey; Smith, David; Bartha, Laura; Montreuil, Jacques; Sherebrin, Shi; Gardi, Lori; Edirisinghe, Chandima; Fenster, Aaron

    2011-02-01

    Ultrasound imaging has improved the treatment of prostate cancer by producing increasingly higher quality images and influencing sophisticated targeting procedures for the insertion of radioactive seeds during brachytherapy. However, it is critical that the needles be placed accurately within the prostate to deliver the therapy to the planned location and avoid complications of damaging surrounding tissues. The authors have developed a compact mechatronic system, as well as an effective method for guiding and controlling the insertion of transperineal needles into the prostate. This system has been designed to allow guidance of a needle obliquely in 3D space into the prostate, thereby reducing pubic arch interference. The choice of needle trajectory and location in the prostate can be adjusted manually or with computer control. To validate the system, a series of experiments were performed on phantoms. The 3D scan of the string phantom produced minimal geometric error, which was less than 0.4 mm. Needle guidance accuracy tests in agar prostate phantoms showed that the mean error of bead placement was less then 1.6 mm along parallel needle paths that were within 1.2 mm of the intended target and 1 degree from the preplanned trajectory. At oblique angles of up to 15 degrees relative to the probe axis, beads were placed to within 3.0 mm along a trajectory that were within 2.0 mm of the target with an angular error less than 2 degrees. By combining 3D TRUS imaging system to a needle tracking linkage, this system should improve the physician's ability to target and accurately guide a needle to selected targets without the need for the computer to directly manipulate and insert the needle. This would be beneficial as the physician has complete control of the system and can safely maneuver the needle guide around obstacles such as previously placed needles.

  16. [Mobile hospital -real time mobile telehealthcare system with ultrasound and CT van using high-speed satellite communication-].

    Science.gov (United States)

    Takizawa, Masaomi; Miyashita, Toyohisa; Murase, Sumio; Kanda, Hirohito; Karaki, Yoshiaki; Yagi, Kazuo; Ohue, Toru

    2003-01-01

    A real-time telescreening system is developed to detect early diseases for rural area residents using two types of mobile vans with a portable satellite station. The system consists of a satellite communication system with 1.5Mbps of the JCSAT-1B satellite, a spiral CT van, an ultrasound imaging van with two video conference system, a DICOM server and a multicast communication unit. The video image and examination image data are transmitted from the van to hospitals and the university simultaneously. Physician in the hospital observes and interprets exam images from the van and watches the video images of the position of ultrasound transducer on screenee in the van. After the observation images, physician explains a results of the examination by the video conference system. Seventy lung CT screening and 203 ultrasound screening were done from March to June 2002. The trial of this real time screening suggested that rural residents are given better healthcare without visit to the hospital. And it will open the gateway to reduce the medical cost and medical divide between city area and rural area.

  17. Combined photoacoustic and ultrasound biomicroscopy.

    Science.gov (United States)

    Harrison, Tyler; Ranasinghesagara, Janaka C; Lu, Huihong; Mathewson, Kory; Walsh, Andrew; Zemp, Roger J

    2009-11-23

    We report on the development of an imaging system capable of combined ultrasound and photoacoustic imaging based on a fast-scanning single-element 25-MHz ultrasound transducer and a unique light-delivery system. The system is capable of 20 ultrasound frames per second and slower photoacoustic frame rates limited by laser pulse-repetition rates. Laser and ultrasound pulses are interlaced for co-registration of photoacoustic and ultrasound images. In vivo imaging of a human finger permits ultrasonic visualization of vessel structures and speckle changes indicative of blood flow, while overlaid photoacoustic images highlight some small vessels that are not clear from the ultrasound scan. Photoacoustic images provide optical absorption contrast co-registered in the structural and blood-flow context of ultrasound with high-spatial resolution and may prove important for clinical diagnostics and basic science of the microvasculature.

  18. An in vitro study of a microbubble contrast agent using a clinical ultrasound imaging system

    Science.gov (United States)

    Sboros, V.; Moran, C. M.; Pye, S. D.; McDicken, W. N.

    2004-01-01

    Optimal insonation settings for contrast imaging are yet to be specified, mainly due to the lack of good understanding of the behaviour of the microbubbles. A satisfactory model that explains the behaviour of individual contrast agent scatterers has not yet been reported in the literature. An in vitro system based on a commercial scanner (ATL HDI3000) has been developed to investigate the backscatter of such agents. Suspensions of Definity® were introduced in an anechoic tank. The frequency of transmitted ultrasound varied from 1 to 5 MHz, pulse period from 2 to 10 periods and peak negative acoustic pressure from 0.08 to 1.7 MPa. The backscatter at the fundamental and second harmonic frequency windows from the agent was normalized in terms of the corresponding components of backscatter from a blood mimicking fluid suspension. The agent provided a dominant resonance effect at 1.6 MHz transmit frequency. Second harmonic normalized backscatter averaged around 9 dB higher than the fundamental. The normalized fundamental backscatter intensity was linear with peak negative pressure. The second harmonic at resonance peaked at 0.5 MPa suggestive of bubble disruption above such pressure. The system proved capable of illustrating the ultrasonic behaviour of Definity® in vitro, and the investigation suggested particular insonation conditions for optimal image enhancement using Definity®.

  19. Implementation of Tissue Harmonic Synthetic Aperture Imaging on a Commercial Ultrasound System

    DEFF Research Database (Denmark)

    Rasmussen, Joachim; Hemmsen, Martin Christian; Madsen, Signe Sloth

    2012-01-01

    This paper presents an imaging technique for synthetic aperture (SAI) tissue harmonic imaging (THI) on a commercial ultrasound system. Synthetic aperture sequential beamforming (SASB) is combined with a pulse inversion (PI) technique on a commercial BK 2202 UltraView system. An interleaved scan...... sequence that performs dynamic receive focused (DRF) imaging and SASB, both using PI, is implemented. From each acquisition four images can be created: DRF image, SASB image, tissue harmonic DRF image (DRF-THI), and tissue harmonic SASB image (SASB-THI). For SASB imaging, a fixed transmit and receive focus...... at 80 mm and an F# of 3 is applied. For DRF imaging, default scanner settings are used, which are a focus at 85 mm and F# of 5.7 in transmit and a dynamic receive aperture with an F# of 0.8. In all cases a 2.14 MHz one-and-ahalf cycle excitation transmit waveform is used. A BK 8820e 192 element convex...

  20. Noninvasive arterial blood pressure waveform monitoring using two- element ultrasound system.

    Science.gov (United States)

    Seo, Joohyun; Pietrangelo, Sabino J; Lee, Hae-Seung; Sodini, Charles G

    2015-04-01

    This work details noninvasive arterial blood pressure (ABP) waveform estimation based on an arterial vessel cross-sectional area measurement combined with an elasticity measurement of the vessel, represented by pulse wave velocity (PWV), using a two-element ultrasound system. The overall ABP waveform estimation is validated in a custom-designed experimental setup mimicking the heart and an arterial vessel segment with two single element transducers, assuming a constant hemodynamic system. The estimation of local PWV using the flow-area method produces unbiased elasticity estimation of the tube in a pressure waveform comparison. The measured PWV using 16 cardiac cycles of data is 8.47 + 0.63 m/s with an associated scaling error of -1.56 + 14.0% in a direct pressure waveform comparison, showing negligible bias error on average. The distension waveform obtained from a complex cross-correlation model estimator (C3M) reliably traces small pressure changes reflected by the diameter change. The excellent agreement of an estimated pressure waveform to the reference pressure waveform suggests the promising potential of a readily available, inexpensive, and portable ABP waveform monitoring device.

  1. Total ankle replacement using HINTEGRA, an unconstrained, three-component system: surgical technique and pitfalls.

    Science.gov (United States)

    Barg, Alexej; Knupp, Markus; Henninger, Heath B; Zwicky, Lukas; Hintermann, Beat

    2012-12-01

    Total ankle replacement (TAR) has become a valuable treatment option in patients with end-stage ankle osteoarthritis. One popular 3-component system, the HINTEGRA TAR, is an unconstrained system that provides inversion-eversion stability. More natural biomechanics of the replaced ankle may be expected when anatomic considerations drive prosthesis design. The HINTEGRA prosthesis includes 2 anatomically contoured metal components and a polyethylene insert, providing axial rotation and physiologic flexion-extension mobility. This article describes the HINTEGRA TAR design and surgical technique. Use of the prosthesis for complex hindfoot reconstruction in patients with an osteoarthritic, varus, or valgus ankle deformity is described.

  2. Carotid Ultrasound

    Science.gov (United States)

    ... this page from the NHLBI on Twitter. Carotid Ultrasound Also known as carotid duplex. Carotid ultrasound is a painless imaging test that uses high- ... of your carotid arteries. This test uses an ultrasound machine, which includes a computer, a screen, and ...

  3. First steps towards ultrasound-based motion compensation for imaging and therapy: calibration with an optical system and 4D PET imaging

    Directory of Open Access Journals (Sweden)

    Julia eSchwaab

    2015-11-01

    Full Text Available Target motion, particularly in the abdomen, due to respiration or patient movement is still a challenge in many diagnostic and therapeutic processes. Hence, methods to detect and compensate this motion are required. Diagnostic ultrasound represents a non-invasive and dose-free alternative to fluoroscopy, providing more information about internal target motion than respiration belt or optical tracking.The goal of this project is to develop an ultrasound based motion tracking for real time motion correction in radiation therapy and diagnostic imaging, notably in 4D positron emission tomography (PET. In this work, a workflow is established to enable the transformation of ultrasound tracking data to the coordinates of the treatment delivery or imaging system – even if the ultrasound probe is moving due to respiration. It is shown that the ultrasound tracking signal is equally adequate for 4D PET image reconstruction as the clinically used respiration belt and provides additional opportunities in this concern. Furthermore, it is demonstrated that the ultrasound probe being within the PET field of view generally has no relevant influence on the image quality. The accuracy and precision of all the steps in the calibration workflow for ultrasound tracking based 4D PET imaging are found to be in an acceptable range for clinical implementation. Eventually, we show in vitro that an ultrasound based motion tracking in absolute room coordinates with a moving US-transducer is feasible.

  4. Photoacoustic imaging system for peripheral small-vessel imaging based on clinical ultrasound technology

    Science.gov (United States)

    Irisawa, Kaku; Hirota, Kazuhiro; Hashimoto, Atsushi; Murakoshi, Dai; Ishii, Hiroyasu; Tada, Takuji; Wada, Takatsugu; Hayakawa, Toshiro; Azuma, Ryuichi; Otani, Naoki; Itoh, Kenji; Ishihara, Miya

    2016-03-01

    One of the features of photoacoustic (PA) imaging is small-vessel visualization realized without injection of a contrast agent or exposure to X-rays. For carrying out clinical studies in this field, a prototype PA imaging system has been developed. The PA imaging system utilizes a technological platform of FUJIFILM's clinical ultrasound (US) imaging system mounting many-core MPU for enhancing the image quality of US B-mode and US Doppler mode, which can be superposed onto PA images. By evaluating the PA and US Doppler images of the prototyped system, the applicability of the prototype system to small-vessel visualization has been discussed. The light source for PA imaging was on a compact cart of a US unit and emitted 750 nm wavelength laser pulses. The laser light was transferred to illumination optics in a handheld US transducer, which was connected to the US unit. Obtained PA rf data is reconstructed into PA images in the US unit. 3D images were obtained by scanning a mechanical stage, which the transducer is attached to. Several peripheral parts such as fingers, palms and wrists were observed by PA and US Doppler imaging. As for small arteries, US Doppler images were able to visualize the bow-shaped artery in the tip of the finger. Though PA images cannot distinguish arteries and veins, it could visualize smaller vessels and showed good resolution and vascular connectivity, resulting in a complementary image for the US Doppler images. Therefore, superposed images of the PA, US B-mode and US Doppler can visualize from large to small vessels without a contrast agent, which should be a differentiating feature of US/PA combined technology from other clinical vascular imaging modalities.

  5. Effect of Ultrasound on the Compaction of Ibuprofen/Isomalt Systems

    Science.gov (United States)

    Fini, Adamo; Cavallari, Cristina; Ospitali, Francesca

    2009-01-01

    Six mixtures, containing 10, 20 and 30% w/w ibuprofen and isomalt, were compacted by a traditional or ultrasound-assisted machine and analysed by means of thermal (DSC and TGA) and micro-spectrometry (Raman and FT-IR) techniques. Ultrasound discharge causes melting of ibuprofen powder, transforming into a paste that could not assume the shape of a tablet; when in mixture with isomalt, thermal events, occurring during ultrasound compaction, change the appearance of the particles formed by milling the tablets obtained this way and SEM photos reveal a dramatic reduction of the particle size and changes due to a possible ibuprofen re-crystallization. Raman and FT-IR spectra of small portions of the surface and of the bulk, using characteristic peaks for identification, reveal that in ultrasound-compacted tablets ibuprofen partially disappears from the top face of the tablet.

  6. A Novel System for the Surgical Staging of Primary High-grade Osteosarcoma: The Birmingham Classification.

    Science.gov (United States)

    Jeys, Lee M; Thorne, Chris J; Parry, Michael; Gaston, Czar Louie L; Sumathi, Vaiyapuri P; Grimer, J Robert

    2017-03-01

    Chemotherapy response and surgical margins have been shown to be associated with the risk of local recurrence in patients with osteosarcoma. However, existing surgical staging systems fail to reflect the response to chemotherapy or define an appropriate safe metric distance from the tumor that will allow complete excision and closely predict the chance of disease recurrence. We therefore sought to review a group of patients with primary high-grade osteosarcoma treated with neoadjuvant chemotherapy and surgical resection and analyzed margins and chemotherapy response in terms of local recurrence. (1) What predictor or combination of predictors available to the clinician can be assessed that more reliably predict the likelihood of local recurrence? (2) Can we determine a better predictor of local recurrence-free survival than the currently applied system of surgical margins? (3) Can we determine a better predictor of overall survival than the currently applied system of surgical margins? This retrospective study included all patients with high-grade conventional osteosarcomas without metastasis at diagnosis treated at one center between 1997 and 2012 with preoperative chemotherapy followed by resection or amputation of the primary tumor who were younger than age 50 years with minimum 24-month followup for those still alive. A total of 389 participants matched the inclusion criteria. Univariate log-rank test and multivariate Cox analyses were undertaken to identify predictors of local recurrence-free survival (LRFS). The Birmingham classification was devised on the basis of two stems: the response to chemotherapy (good response = ≥ 90% necrosis; poor response = HR], 9.9; 95% CI, 1.2-82; p = 0.03 versus radical margin HR, 1) and a poor response to neoadjuvant chemotherapy (HR, 3.8; 95% CI, 1.7-8.4; p = 0.001 versus good response HR, 1) were independent risk factors for local recurrence (LR). The best predictor of LR, however, was a combination of margins ≤ 2 mm and

  7. Image-Guided Surgical Robotic System for Percutaneous Reduction of Joint Fractures.

    Science.gov (United States)

    Dagnino, Giulio; Georgilas, Ioannis; Morad, Samir; Gibbons, Peter; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2017-08-16

    Complex joint fractures often require an open surgical procedure, which is associated with extensive soft tissue damages and longer hospitalization and rehabilitation time. Percutaneous techniques can potentially mitigate these risks but their application to joint fractures is limited by the current sub-optimal 2D intra-operative imaging (fluoroscopy) and by the high forces involved in the fragment manipulation (due to the presence of soft tissue, e.g., muscles) which might result in fracture malreduction. Integration of robotic assistance and 3D image guidance can potentially overcome these issues. The authors propose an image-guided surgical robotic system for the percutaneous treatment of knee joint fractures, i.e., the robot-assisted fracture surgery (RAFS) system. It allows simultaneous manipulation of two bone fragments, safer robot-bone fixation system, and a traction performing robotic manipulator. This system has led to a novel clinical workflow and has been tested both in laboratory and in clinically relevant cadaveric trials. The RAFS system was tested on 9 cadaver specimens and was able to reduce 7 out of 9 distal femur fractures (T- and Y-shape 33-C1) with acceptable accuracy (≈1 mm, ≈5°), demonstrating its applicability to fix knee joint fractures. This study paved the way to develop novel technologies for percutaneous treatment of complex fractures including hip, ankle, and shoulder, thus representing a step toward minimally-invasive fracture surgeries.

  8. Surgical clothing systems in laminar airflow operating room: a numerical assessment.

    Science.gov (United States)

    Sadrizadeh, Sasan; Holmberg, Sture

    2014-01-01

    This study compared two different laminar airflow distribution strategies - horizontal and vertical - and investigated the effectiveness of both ventilation systems in terms of reducing the sedimentation and distribution of bacteria-carrying particles. Three different staff clothing systems, which resulted in source strengths of 1.5, 4 and 5 CFU/s per person, were considered. The exploration was conducted numerically using a computational fluid dynamics technique. Active and passive air sampling methods were simulated in addition to recovery tests, and the results were compared. Model validation was performed through comparisons with measurement data from the published literature. The recovery test yielded a value of 8.1 min for the horizontal ventilation scenario and 11.9 min for the vertical ventilation system. Fewer particles were captured by the slit sampler and in sedimentation areas with the horizontal ventilation system. The simulated results revealed that under identical conditions in the examined operating room, the horizontal laminar ventilation system performed better than the vertical option. The internal constellation of lamps, the surgical team and objects could have a serious effect on the movement of infectious particles and therefore on postoperative surgical site infections.

  9. Transbronchial and transesophageal fine-needle aspiration using a single ultrasound bronchoscope in the diagnosis of locoregional recurrence of surgically-treated lung cancer.

    Science.gov (United States)

    Sanz-Santos, José; Serra, Pere; Andreo, Felipe; Torky, Mohamed; Centeno, Carmen; Morán, Teresa; Carcereny, Enric; Fernández, Esther; García-Reina, Samuel; Ruiz-Manzano, Juan

    2017-02-28

    The present study sought to evaluate the usefulness of EBUS-TBNA in the diagnosis of locoregional recurrence of lung cancer in a cohort of lung cancer patients who were previously treated surgically, and describe our initial experience of EUS-B-FNA in this clinical scenario. We retrospectively studied the clinical records of all patients with a previous surgically-treated lung cancer who were referred to our bronchoscopy unit after suspicion of locoregional recurrence. The diagnostic sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and overall accuracy of EBUS-TBNA for the diagnosis of locoregional recurrence were evaluated. Seventy-three patients were included. EBUS-TBNA confirmed malignancy in 40 patients: 34 confirmed to have locoregional recurrence, six had metachronous tumours. Of the 33 patients with non-malignant EBUS-TBNA; 2 had specific non-malignant diseases, 26 underwent radiological follow up and 5 patients underwent surgery. Of the 26 patients who had radiological follow up; 18 remained stable, three presented thoracic radiological progression and 5 presented extrathoracic progression. Of the 5 patients who underwent surgery; 3 had metachronous tumours, one confirmed to be a true negative and one presented nodal invasion. Seven patients underwent EUS-B-FNA, four of them confirmed to have recurrence. The sensitivity, specificity, NPV, PPV and overall accuracy of EBUS-TBNA for the diagnosis of locoregional recurrence were 80.9, 100, 69.2, 100 and 86.6% respectively. EBUS-TBNA is an accurate procedure for the diagnosis of locoregional recurrence of surgically-treated lung cancer. EUS-B-FNA combined with EBUS-TBNA broads the diagnostic yield of EBUS-TBNA alone.

  10. Towards a Reduced-Wire Interface for CMUT-Based Intravascular Ultrasound Imaging Systems.

    Science.gov (United States)

    Lim, Jaemyung; Tekes, Coskun; Degertekin, F Levent; Ghovanloo, Maysam

    2017-04-01

    Having intravascular ultrasound (IVUS) imaging capability on guide wires used in cardiovascular interventions may eliminate the need for separate IVUS catheters and expand the use of IVUS in a larger portion of the vasculature. High frequency capacitive micro machined ultrasonic transducer (CMUT) arrays should be integrated with interface electronics and placed on the guide wire for this purpose. Besides small size, this system-on-a-chip (SoC) front-end should connect to the back-end imaging system with a minimum number of wires to preserve the critical mechanical properties of the guide wire. We present a 40 MHz CMUT array interface SoC, which will eventually use only two wires for power delivery and transmits image data using a combination of analog-to-time conversion (ATC) and an impulse radio ultra-wideband (IR-UWB) wireless link. The proof-of-concept prototype ASIC consumes only 52.8 mW and occupies 4.07 [Formula: see text] in a 0.35- [Formula: see text] standard CMOS process. A rectifier and regulator power the rest of the SoC at 3.3 V from a 10 MHz power carrier that is supplied through a 2.4 m micro-coax cable with an overall efficiency of 49.1%. Echo signals from an 8-element CMUT array are amplified by a transimpedance amplifier (TIA) array and down-converted to baseband by quadrature sampling using a 40 MHz clock, derived from the power carrier. The ATC generates pulse-width-modulated (PWM) samples at 2 × 10 MS/s with 6 bit resolution, while the entire system achieved 5.1 ENOB. Preliminary images from the prototype system are presented, and alternative data transmission and possible future directions towards practical implementation are discussed.

  11. Comparison of two actuation systems for laparoscopic surgical manipulators using motion analysis.

    Science.gov (United States)

    Kolwadkar, Yogesh Vinod; Brown, Stuart I; Abboud, Rami J; Wang, Weijie

    2011-03-01

    During surgery, all joints of the upper limbs, including shoulder, elbow, wrist, and finger, coordinate to complete a task. Hence, analysis of these joint movements during surgical manipulations is useful for the design of optimal hand-instrument interface. This study compared two types of surgical handheld manipulators with 6 degrees of freedom with different handle designs: one using a controlling wheel (fingertip control, FTC) and the other with a controlling joint (master slave control, MSC) in terms of ergonomics and movement efficiency. Seventeen subjects consisting of surgeons and medical students participated in the experiment. Each performed two standardized surgical tasks in a surgical simulator. A set of reflective markers were attached on the subjects' upper limbs and the marker positions during the tasks were collected by a motion capture system for subsequent analysis of the trunk, shoulder, elbow, wrist, and fingers joint movements. The subjects also completed a Visual Analogue Scale-based questionnaire on their preference for the control mechanism and ease of handling. The data showed that the manipulator with the MSC was more difficult to handle and resulted in larger range of movements, higher velocities, and accelerations in some joints than the manipulator with FTC mechanism. Use of the MSC manipulator also was accompanied by a higher error rate. Additionally, the subjects preferred the finger actuated manipulator and gave it a higher Visual Analogue Score for maneuverability. The manipulator equipped with the MSC was ergonomically inferior; it was more difficult to handle and provided less precision, resulting in higher error rates than the FTC manipulator. This study also confirmed that motion analysis is useful for assessment of the design of handheld manipulators for endoscopic surgery.

  12. The utilization of an ultrasound-guided 8-gauge vacuum-assisted breast biopsy system as an innovative approach to accomplishing complete eradication of multiple bilateral breast fibroadenomas

    Directory of Open Access Journals (Sweden)

    Povoski Stephen P

    2007-10-01

    Full Text Available Abstract Background Ultrasound-guided vacuum-assisted breast biopsy technology is extremely useful for diagnostic biopsy of suspicious breast lesions and for attempted complete excision of appropriately selected presumed benign breast lesions. Case presentation A female patient presented with 16 breast lesions (eight within each breast, documented on ultrasound and all presumed to be fibroadenomas. Over a ten and one-half month period of time, 14 of these 16 breast lesions were removed under ultrasound guidance during a total of 11 separate 8-gauge Mammotome® excision procedures performed during seven separate sessions. Additionally, two of these 16 breast lesions were removed by open surgical excision. A histopathologic diagnosis of fibroadenoma and/or fibroadenomatous changes was confirmed at all lesion excision sites. Interval follow-up ultrasound imaging revealed no evidence of a residual lesion at the site of any of the 16 original breast lesions. Conclusion This report describes an innovative approach of utilizing ultrasound-guided 8-gauge vacuum-assisted breast biopsy technology for assisting in achieving complete eradication of multiple bilateral fibroadenomas in a patient who presented with 16 documented breast lesions. As such, this innovative approach is highly recommended in similar appropriately selected patients.

  13. Feasibility of coded vibration in a vibro-ultrasound system for tissue elasticity measurement.

    Science.gov (United States)

    Zhao, Jinxin; Wang, Yuanyuan; Yu, Jinhua; Li, Tianjie; Zheng, Yong-Ping

    2016-07-01

    The ability of various methods for elasticity measurement and imaging is hampered by the vibration amplitude on biological tissues. Based on the inference that coded excitation will improve the performance of the cross-correlation function of the tissue displacement waves, the idea of exerting encoded external vibration on tested samples for measuring its elasticity is proposed. It was implemented by integrating a programmable vibration generation function into a customized vibro-ultrasound system to generate Barker coded vibration for elasticity measurement. Experiments were conducted on silicone phantoms and porcine muscles. The results showed that coded excitation of the vibration enhanced the accuracy and robustness of the elasticity measurement especially in low signal-to-noise ratio scenarios. In the phantom study, the measured shear modulus values with coded vibration had an R(2 )= 0.993 linear correlation to that of referenced indentation, while for single-cycle pulse the R(2) decreased to 0.987. In porcine muscle study, the coded vibration also obtained a shear modulus value which is more accurate than the single-cycle pulse by 0.16 kPa and 0.33 kPa at two different depths. These results demonstrated the feasibility and potentiality of the coded vibration for enhancing the quality of elasticity measurement and imaging.

  14. Numerical study of a simple transcranial focused ultrasound system applied to blood-brain barrier opening.

    Science.gov (United States)

    Deffieux, Thomas; Konofagou, Elisa E

    2010-12-01

    In this paper, we investigate the focalization properties of single-element transducers at low frequencies (300 to 1000 kHz) through primate and human skulls. The study addresses the transcranial targeting involved in ultrasound- induced blood-brain barrier (BBB) opening with clinically relevant targets such as the hippocampus and the basal ganglia, which are typically affected by early Alzheimer's and Parkinson's disease, respectively. A finite-difference, timedomain simulation platform is used to solve the 3-D linear acoustic wave equation with CT-based acoustic maps of the skulls. The targeted brain structures were extracted from 3-D brain atlases registered with the skulls and used to virtually position and orient the transducers. The effect of frequency is first investigated and the targeting of the different structures is then tested. The frequency of 500 kHz provided the best tradeoff between phase aberrations and standing wave effects in the human case, whereas the frequency of 800 kHz was most suitable in the case of the primate skull. A fast periodic linear chirp method was developed and found capable of reducing the standing wave effects. Such a simple, affordable, and convenient system is concluded to be feasible for BBB opening in primates and humans and could thus allow for its broader impact and applications.

  15. Ultrasound-Assisted Aqueous Two-Phase System for Extraction and Enrichment of Zanthoxylum armatum Lignans

    Directory of Open Access Journals (Sweden)

    Tao Guo

    2015-08-01

    Full Text Available In the study, an aqueous two phase system (ATPS coupled with ultrasound was employed to extract lignans from Zanthoxylum armatum. Three standard lignans, namely (−-fargesin, sesamin and L-asarinin, were used as marker compounds, and extraction was optimized and projected by response surface methodology (RSM and artificial neural network (ANN. The optimal condition for ATPS with 20% n-propanol and 24% (NH42SO4 coupled with ultrasonic-assisted extraction including a solvent to solid ratio of 15:1, a temperature of 40 °C, and a treatment time of 55 min was obtained. Under the condition, the yield of (−-fargesin increased 15.12%, and the purities of (−-fargesin, sesamin and L-asarinin reached 2.222%, 1.066%, and 1.583%, with an increase of 44.38%, 25.70%, and 26.34% compared to those extracted with 95% ethanol, respectively. Coefficient of the determined (0.9855 and mean squared error (0.0018 of ANN model suggested good fitness and generalization of the ANN. Taken together, the results showed that ultrasonic-assisted ATPS can be a suitable method for extraction and enrichment of lignans from Z. armatum.

  16. Ultrasound-mediated gene and drug delivery using a microbubble-liposome particle system.

    Science.gov (United States)

    Yoon, Young Il; Kwon, Yong-Su; Cho, Hee-Sang; Heo, Sun-Hee; Park, Kyeong Soon; Park, Sang Gyu; Lee, Soo-Hong; Hwang, Seung Il; Kim, Young Il; Jae, Hwan Jun; Ahn, Gook-Jun; Cho, Young-Seok; Lee, Hakho; Lee, Hak Jong; Yoon, Tae-Jong

    2014-01-01

    Theranostic agents present a promising clinical approach for cancer detection and treatment. We herein introduce a microbubble and liposome complex (MB-Lipo) developed for ultrasound (US) imaging and activation. The MB-Lipo particles have a hybrid structure consisting of a MB complexed with multiple Lipos. The MB components are used to generate high echo signals in US imaging, while the Lipos serve as a versatile carrier of therapeutic materials. MB-Lipo allows high contrast US imaging of tumor sites. More importantly, the application of high acoustic pressure bursts MBs, which releases therapeutic Lipos and further enhances their intracellular delivery through sonoporation effect. Both imaging and drug release could thus be achieved by a single US modality, enabling in situ treatment guided by real-time imaging. The MB-Lipo system was applied to specifically deliver anti-cancer drug and genes to tumor cells, which showed enhanced therapeutic effect. We also demonstrate the clinical potential of MB-Lipo by imaging and treating tumor in vivo.

  17. A new method for uniform local heating deep in body using ultrasound phased-array system

    Institute of Scientific and Technical Information of China (English)

    Zhang Chenxi; Bai Jingfeng; Chen Yazhu

    2008-01-01

    A new method for targeted heating of deep tissue was developed by using an ultrasound phased-array system which can generate various multiple foci patterns by electronically changing its amplitude or phase pattern. This method involves using a technique of combining switching and rotating of multiple foci patterns to create a uniform temperature over tissue volumes in various size. Using this method, the target tissue deep in the body can be heated to a specified temperature, which gives conditions for thermo-sensitive liposomes release. A simulation study for a 108-element, spherically sectioned array was performed to determine an optimal heating scheme from a set of multiple focus fields which were produced by inputting different combinations of phases and amplitudes. Comparisons of a static multiple foci field, the switched fields and the switched-rotated fields indicated that the technique of combining switching and rotating of multiple foci patterns has advantages of both lowering the peak temperature and evening the temperature distribution. The simulation results also show that the therapeutic heating zones in various size employing the combined method. These results offer significant data for designing thermotherapy equipment for tumor-specific drug release with thermo-sensitive liposomes.

  18. Performance characterization of an integrated ultrasound, photoacoustic, and thermoacoustic imaging system

    Science.gov (United States)

    Ke, Haixin; Erpelding, Todd N.; Jankovic, Ladislav; Liu, Changjun; Wang, Lihong V.

    2012-05-01

    We developed a novel trimodality system for human breast imaging by integrating photoacoustic (PA) and thermoacoustic (TA) imaging techniques into a modified commercial ultrasound scanner. Because light was delivered with an optical assembly placed within the microwave antenna, no mechanical switching between the microwave and laser sources was needed. Laser and microwave excitation pulses were interleaved to enable PA and TA data acquisition in parallel at a rate of 10 frames per second. A tube (7 mm inner diameter) filled with oxygenated bovine blood or 30 mM methylene blue dye was successfully detected in PA images in chicken breast tissue at depths of 6.6 and 8.4 cm, respectively, for the first time. The SNRs at these depths reached ˜24 and ˜15 dB, respectively, by averaging 200 signal acquisitions. Similarly, a tube (13 mm inner diameter) filled with saline solution (0.9%) at a depth of 4.4 cm in porcine fat tissue was successfully detected in TA images. The PA axial, lateral, and elevational resolutions were 640 μm, 720 μm, and 3.5 mm, respectively, suitable for breast cancer imaging. A PA noise-equivalent sensitivity to methylene blue solution of 260 nM was achieved in chicken tissue at a depth of 3.4 cm.

  19. System-Level Design of an Integrated Receiver Front End for a Wireless Ultrasound Probe

    DEFF Research Database (Denmark)

    di Ianni, Tommaso; Hemmsen, Martin Christian; Llimos Muntal, Pere

    2016-01-01

    In this paper, a system-level design is presented for an integrated receive circuit for a wireless ultrasound probe, which includes analog front ends and beamformation modules. This paper focuses on the investigation of the effects of architectural design choices on the image quality. The point...... spread function is simulated in Field II from 10 to 160 mm using a convex array transducer. A noise analysis is performed, and the minimum signal-to-noise ratio (SNR) requirements are derived for the low-noise amplifiers (LNAs) and A/D converters (ADCs) to fulfill the design specifications of a dynamic......). The designs that minimally satisfy the specifications are based on an 8-b 30-MSPS Nyquist converter and a single-bit third-order 240-MSPS modulator, with an SNR for the LNA in both cases equal to 64 dB. The mean lateral FWHM and CR are 2.4% and 7.1% lower for the architecture compared with the Nyquistrate one...

  20. Long-term follow-up of surgically excluded popliteal artery aneurysms with multi-slice CT angiography and Doppler ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Deglise, Sebastien; Haller, Claude; Corpataux, Jean-Marc [CHUV, Department of Thoracic and Vascular Surgery, Lausanne (Switzerland); Qanadli, Salah D.; Rizzo, Elena; Doenz, Francesco; Denys, Alban [University Hospital CHUV-University of Lausanne, Department of Radiology, Lausanne (Switzerland); Ducrey, Nicolas [CHUV, Department of Angiology, Lausanne (Switzerland)

    2006-06-15

    The purpose of this study was to evaluate the role of multi-slice computed tomography (MSCT) angiography in the follow-up of popliteal artery aneurysms (PAAs) that have been operated on. Aneurysm exclusion and progression, graft patency and graft-related complications were analyzed. Fourteen patients with 21 surgically excluded PAAs were evaluated with MSCT angiography with slice thickness of 1.25 mm. The mean follow-up time was 67 months. MSCT demonstrated blood flow in six non-excluded PAAs (24%), with an average increase in the diameter of 21 mm over time. Fifteen PAAs demonstrated no blood flow and revealed an average decrease of 7 mm in diameter. The origin of this residual perfusion was demonstrated, and collaterals were involved in five of six non-excluded PAAs. In addition, MSCT demonstrated three graft stenoses. Furthermore, two occluded grafts were visualized. Twenty-four percent of the patients after surgical exclusion of PAAs revealed residual perfusion within the aneurysmal sac during follow-up, with a significant increase in the aneurysmal size with MSCT. Moreover, evaluation of the graft patency could also be done as could demonstration of anastomotic abnormalities. Thus, MSCT might be considered as a new tool to evaluate residual collateral feeding of popliteal aneurysmal sac and could be useful in identification and localization of feeding vessels. (orig.)

  1. Kinect based real-time position calibration for nasal endoscopic surgical navigation system

    Science.gov (United States)

    Fan, Jingfan; Yang, Jian; Chu, Yakui; Ma, Shaodong; Wang, Yongtian

    2016-03-01

    Unanticipated, reactive motion of the patient during skull based tumor resective surgery is the source of the consequence that the nasal endoscopic tracking system is compelled to be recalibrated. To accommodate the calibration process with patient's movement, this paper developed a Kinect based Real-time positional calibration method for nasal endoscopic surgical navigation system. In this method, a Kinect scanner was employed as the acquisition part of the point cloud volumetric reconstruction of the patient's head during surgery. Then, a convex hull based registration algorithm aligned the real-time image of the patient head with a model built upon the CT scans performed in the preoperative preparation to dynamically calibrate the tracking system if a movement was detected. Experimental results confirmed the robustness of the proposed method, presenting a total tracking error within 1 mm under the circumstance of relatively violent motions. These results point out the tracking accuracy can be retained stably and the potential to expedite the calibration of the tracking system against strong interfering conditions, demonstrating high suitability for a wide range of surgical applications.

  2. A two-view ultrasound CAD system for spina bifida detection using Zernike features

    Science.gov (United States)

    Konur, Umut; Gürgen, Fikret; Varol, Füsun

    2011-03-01

    In this work, we address a very specific CAD (Computer Aided Detection/Diagnosis) problem and try to detect one of the relatively common birth defects - spina bifida, in the prenatal period. To do this, fetal ultrasound images are used as the input imaging modality, which is the most convenient so far. Our approach is to decide using two particular types of views of the fetal neural tube. Transcerebellar head (i.e. brain) and transverse (axial) spine images are processed to extract features which are then used to classify healthy (normal), suspicious (probably defective) and non-decidable cases. Decisions raised by two independent classifiers may be individually treated, or if desired and data related to both modalities are available, those decisions can be combined to keep matters more secure. Even more security can be attained by using more than two modalities and base the final decision on all those potential classifiers. Our current system relies on feature extraction from images for cases (for particular patients). The first step is image preprocessing and segmentation to get rid of useless image pixels and represent the input in a more compact domain, which is hopefully more representative for good classification performance. Next, a particular type of feature extraction, which uses Zernike moments computed on either B/W or gray-scale image segments, is performed. The aim here is to obtain values for indicative markers that signal the presence of spina bifida. Markers differ depending on the image modality being used. Either shape or texture information captured by moments may propose useful features. Finally, SVM is used to train classifiers to be used as decision makers. Our experimental results show that a promising CAD system can be actualized for the specific purpose. On the other hand, the performance of such a system would highly depend on the qualities of image preprocessing, segmentation, feature extraction and comprehensiveness of image data.

  3. A Target-Orientated Marker Image Binarization Method for Orthopaedic Surgical Navigation System

    Institute of Scientific and Technical Information of China (English)

    YAN Shi-ju; CHEN Xiao-jun; WANG Cheng-tao; SU Ying-ying; XIA Qing

    2007-01-01

    Camera calibration is the key technique in a C-arm based orthopaedic surgical navigation system. The extraction of marker location information is a necessary step in the calibration process. Ideal marker images should possess uniform background and contain marker shadow only, but in fact marker images always possess nonuniform background and are contaminated by noise and unwanted anatomic information, making the extraction very difficult. A target-orientated marker shadow extraction method was proposed. With this method a proper threshold for marker image binarization can be determined.

  4. 21 CFR 878.4410 - Low energy ultrasound wound cleaner.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Low energy ultrasound wound cleaner. 878.4410... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4410 Low energy ultrasound wound cleaner. (a) Identification. A low energy ultrasound wound cleaner is a device that...

  5. A high-accuracy surgical augmented reality system using enhanced integral videography image overlay.

    Science.gov (United States)

    Zhang, Xinran; Chen, Guowen; Liao, Hongen

    2015-01-01

    Image guided surgery has been used in clinic to improve the surgery safety and accuracy. Augmented reality (AR) technique, which can provide intuitive image guidance, has been greatly evolved these years. As one promising approach of surgical AR systems, integral videography (IV) autostereoscopic image overlay has achieved accurate fusion of full parallax guidance into surgical scene. This paper describes an image enhanced high-accuracy IV overlay system. A flexible optical image enhancement system (IES) is designed to increase the resolution and quality of IV image. Furthermore, we introduce a novel IV rendering algorithm to promote the spatial accuracy with the consideration of distortion introduced by micro lens array. Preliminary experiments validated that the image accuracy and resolution are improved with the proposed methods. The resolution of the IV image could be promoted to 1 mm for a micro lens array with pitch of 2.32 mm and IES magnification value of 0.5. The relative deviation of accuracy in depth and lateral directions are -4.68 ± 0.83% and -9.01 ± 0.42%.

  6. The Fenix System for Fecal Incontinence: An Overview and Surgical Demonstration.

    Science.gov (United States)

    DeStephano, Christopher C; Chen, Anita H; Pettit, Paul D

    2017-05-03

    This video shows a new technique for the surgical management of fecal incontinence using the Fenix Continence Restoration System (TORAX Medical Inc, Shoreview, MN) in 2 patients. A step-by-step explanation of the video using videos and pictures (educational video) for surgeons (Canadian Task Force classification III). The use of the Fenix System received United States Food and Drug Administration approval under a humanitarian device exemption and can be used with institutional review board approval in patients who have failed previous medical and surgical management of fecal incontinence. The device is a small, flexible band of interlinked titanium, magnetic beads on a titanium string that is placed using a perineal approach around the anal canal. Increased intra-abdominal pressure opens the beads to allow for the passage of stool. Placement of the device was performed in 2 patients. Case 1 is a 63-year-old woman with a long-standing history of fecal incontinence who failed sphincteroplasty, sacral neuromodulation, and an artificial sphincter cuff and pump. Case 2 is a 60-year-old woman with a long-standing history of fecal incontinence secondary to radiation therapy for rectal cancer who failed physical therapy and sacral neuromodulation. Both Fenix Continence Restoration Systems were placed successfully. Long-term postoperative effectiveness is currently being evaluated. Copyright © 2017 AAGL. Published by Elsevier Inc. All rights reserved.

  7. Hybrid procedure for total laryngectomy with a flexible robot-assisted surgical system.

    Science.gov (United States)

    Schuler, Patrick J; Hoffmann, Thomas K; Veit, Johannes A; Rotter, Nicole; Friedrich, Daniel T; Greve, Jens; Scheithauer, Marc O

    2017-06-01

    Total laryngectomy is a standard procedure in head-and-neck surgery for the treatment of cancer patients. Recent clinical experiences have indicated a clinical benefit for patients undergoing transoral robot-assisted total laryngectomy (TORS-TL) with commercially available systems. Here, a new hybrid procedure for total laryngectomy is presented. TORS-TL was performed in human cadavers (n = 3) using a transoral-transcervical hybrid procedure. The transoral approach was performed with a robotic flexible robot-assisted surgical system (Flex®) and compatible flexible instruments. Transoral access and visualization of anatomical landmarks were studied in detail. Total laryngectomy is feasible with a combined transoral-transcervical approach using the flexible robot-assisted surgical system. Transoral visualization of all anatomical structures is sufficient. The flexible design of the robot is advantageous for transoral surgery of the laryngeal structures. Transoral robot assisted surgery has the potential to reduce morbidity, hospital time and fistula rates in a selected group of patients. Initial clinical studies and further development of supplemental tools are in progress. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  8. Ultrasound assisted free radical polymerization of glycidyl methacrylate by a new disite phase-transfer catalyst system: A kinetic study.

    Science.gov (United States)

    Sankar, Kavitha; Rajendran, Venugopal

    2012-11-01

    The kinetics of multi-site phase-transfer catalyzed free radical polymerisation of glycidyl methacrylate (GMA) using potassium peroxy disulphate (PDS) as water soluble initiator and newly synthesized 1,4-dihexadecylpyrazine-1,4-diium dibromide as multi-site phase-transfer catalyst (MPTC) has been investigated in ethyl acetate/water two phase system at constant temperature 65±1°C under nitrogen atmosphere and ultrasound irradiation conditions. The rate of polymerization increases with an increase in concentrations of GMA, PDS and MPTC. The order with respect to monomer, initiator and MPTC were found to be 1.0, 0.5 and 1.0, respectively. The comparative study reveals that the Rp of GMA determined in the presence of PTC combined with ultrasound has shown more enhancements in the activity than PTC alone. Based on the observed results a suitable mechanism has been proposed to account for the experimental observations and its significance was discussed.

  9. A Comparative Analysis of Ultrasound Velocity in Binary Liquid Systems of PPG by Mathematical and Experimental Methods

    Science.gov (United States)

    Gayathri, A.; Venugopal, T.; Venkatramanan, K.

    The estimation of the speed of ultrasound is the fundamental requirement for investigating the transport properties of liquid and solid systems. Ultrasonic velocities of liquid mixtures containing polar and non-polar groups are of considerable importance in understanding inter-molecular interaction between component molecules and they find applications in several industrial and technological processes. There are many standard mathematical methods available to measure the ultrasonic velocity. In the present study, interferometric technique is planned for experimental measurement of ultrasound velocity. In this paper, the speed of ultrasound waves in Polypropylene Glycol (PPG 400, PPG 4000) in toluene has been estimated for different concentrations (2%, 4%, 6%, 8% & 10%) at 303K and these experimental values compared with theoretical values obtained by using various mathematical methods like Nomotto's Relation, Vandeal Vangeal Relation, Impedance Relation, and Rao's specific sound velocity. The most reliable method that matches with experimental method is identified using Average Percentage Error (APE) and analysed in the light of molecular interactions occurring in the binary liquid systems. Comparison of evaluated theoretical velocities with experimental values will reveal the nature of interaction between component molecules in the mixtures. Such theoretical study is useful in defining a comprehensive theoretical model for a specific liquid mixture. Also, various molecular interaction parameters like free volume, internal pressure, viscous relaxation time, inter atomic free length, etc are calculated and discussed in terms of polymer-solvent interactions.

  10. The concordance between thyroid nodules ultrasound, based on thyroid Imaging reporting and data systems, and fine needle aspiration

    Directory of Open Access Journals (Sweden)

    Nazanin Farshchian

    2016-03-01

    Full Text Available Background: Thyroid nodules are solid or cystic lumps within the thyroid gland. The purpose of this study was to evaluate the concordance between thyroid nodules ultrasound reports, based on Thyroid Imaging Reporting and Data (TIRAD System and results of ultrasound guided Fine Needle Aspiration (FNA. Methods: In this cross-sectional study, 144 patients with thyroid nodules who referred to the radiology department of Imam Reza Hospital of Kermanshah at the request of endocrinologist were evaluated. Data were analyzed by SPSS-21software using descriptive statistics. Results: The age range of patients was 15 to 78, with mean age 44.86±13.27 years. Of the sample, 141 cases (97.9 % were female and 3 cases (2.1 % were male. Based on the results of pathology, 130 (90.2% were benign and 14 (9.8% were malignant lesions and sonography result 129 cases (89.6% were benign and 15 cases (10.4% were malignant. There was a significant difference between the results of sonography and FNA and Kappa agreement test showed a significant concordance (96% between the sonographic reports of thyroid nodules, based on TIRAD system, and pathological findings. Conclusion: The results of this study indicated a high concordance between sonographic reports of thyroid nodules, based on TIRAD category, and FNA findings. Thus, TIRAD-based ultrasound can play a key role in determining thyroid nodules, thereby facilitating patient's management.

  11. Gaseous microemboli detection in a simulated pediatric CPB circuit using a novel ultrasound system.

    Science.gov (United States)

    Miller, Akemi; Wang, Shigang; Myers, John L; Undar, Akif

    2008-01-01

    The objective of this study was to evaluate the effect of flow rate and perfusion mode on the delivery of gaseous microemboli in a simulated pediatric cardiopulmonary bypass (CPB) circuit with an open arterial filter purge line using a novel ultrasound detection system. The circuit was primed with 450 ml fresh, heparinized bovine blood plus 200 ml Lactated Ringer's solution (total volume 650 ml, corrected Hct 25%). After the injection of 5 ml air into the venous line, an Emboli Detection and Classification (EDAC) Quantifier (Luna Innovations, Inc., Roanoke, VA) was used to simultaneously record microemboli counts at postpump, postoxygenator, and postarterial filter sites. Trials were conducted at four different flow rates (500, 750, 1,000, 1,250 ml/min) and two perfusion modes (pulsatile, nonpulsatile). Microemboli counts uniformly increased with increasing pump flow rates. In all trials, the majority of gaseous microemboli detected in the simulated pediatric CPB circuit were 10 microm) were cleared from the circuit by the oxygenator and arterial filter. Clearance efficiency was decreased at higher flow rates (750-1,250 ml/min). Over 98% of microemboli detected at the postoxygenator site were <40 microm in diameter. In general, pulsatile flow delivered more microemboli to the circuit at postpump and postoxygenator sites than nonpulsatile flow. The results of this study confirmed that entrained air from the venous line could be delivered to the systemic circulation (as represented by our pediatric pseudo patient) at flow rates from 750 to 1,250 ml/min, despite the presence of an arterial filter and open arterial filter purge line. All of the microemboli distal to the arterial filter were smaller than the conventional detectable level of 40 microm.

  12. The study of surgical image quality evaluation system by subjective quality factor method

    Science.gov (United States)

    Zhang, Jian J.; Xuan, Jason R.; Yang, Xirong; Yu, Honggang; Koullick, Edouard

    2016-03-01

    GreenLightTM procedure is an effective and economical way of treatment of benign prostate hyperplasia (BPH); there are almost a million of patients treated with GreenLightTM worldwide. During the surgical procedure, the surgeon or physician will rely on the monitoring video system to survey and confirm the surgical progress. There are a few obstructions that could greatly affect the image quality of the monitoring video, like laser glare by the tissue and body fluid, air bubbles and debris generated by tissue evaporation, and bleeding, just to name a few. In order to improve the physician's visual experience of a laser surgical procedure, the system performance parameter related to image quality needs to be well defined. However, since image quality is the integrated set of perceptions of the overall degree of excellence of an image, or in other words, image quality is the perceptually weighted combination of significant attributes (contrast, graininess …) of an image when considered in its marketplace or application, there is no standard definition on overall image or video quality especially for the no-reference case (without a standard chart as reference). In this study, Subjective Quality Factor (SQF) and acutance are used for no-reference image quality evaluation. Basic image quality parameters, like sharpness, color accuracy, size of obstruction and transmission of obstruction, are used as subparameter to define the rating scale for image quality evaluation or comparison. Sample image groups were evaluated by human observers according to the rating scale. Surveys of physician groups were also conducted with lab generated sample videos. The study shows that human subjective perception is a trustworthy way of image quality evaluation. More systematic investigation on the relationship between video quality and image quality of each frame will be conducted as a future study.

  13. Predictive model for contrast-enhanced ultrasound of the breast: Is it feasible in malignant risk assessment of breast imaging reporting and data system 4 lesions?

    Institute of Scientific and Technical Information of China (English)

    Jun Luo; Ji-Dong Chen; Qing Chen; Lin-Xian Yue; Guo Zhou; Cheng Lan; Yi Li; Chi-Hua Wu; Jing-Qiao Lu

    2016-01-01

    AIM: To build and evaluate predictive models for contrast-enhanced ultrasound(CEUS) of the breast to distinguish between benign and malignant lesions. METHODS: A total of 235 breast imaging reporting and data system(BI-RADS) 4 solid breast lesions were imaged via CEUS before core needle biopsy or surgical resection. CEUS results were analyzed on 10 enhancing patterns to evaluate diagnostic performance of three benign and three malignant CEUS models, with pathological results used as the gold standard. A logistic regression model was developed basing on the CEUS results, and then evaluated with receiver operating curve(ROC). RESULTS: Except in cases of enhanced homogeneity, the rest of the 9 enhancement appearances were statistically significant(P < 0.05). These 9 enhancement patterns were selected in the final step of the logistic regression analysis, with diagnostic sensitivity and specificity of 84.4% and 82.7%, respectively, and the area under the ROC curve of 0.911. Diagnostic sensitivity, specificity, and accuracy of the malignant vs benign CEUS models were 84.38%, 87.77%, 86.38% and 86.46%, 81.29% and 83.40%, respectively. CONCLUSION: The breast CEUS models can predict risk of malignant breast lesions more accurately, decrease false-positive biopsy, and provide accurate BIRADS classification.

  14. Surgical Site Infection (SSI) Rates in the United States, 1992-1998: The National Nosocomial Infections Surveillance System Basic SSI Risk Index

    National Research Council Canada - National Science Library

    Robert P. Gaynes; David H. Culver; Teresa C. Horan; Jonathan R. Edwards; Chesley Richards; James S. Tolson; The National Nosocomial Infections Surveillance System

    2001-01-01

    By use of the National Nosocomial Infections Surveillance (NNIS) System's surgical patient surveillance component protocol, the NNIS basic risk index was examined to predict the risk of a surgical site infection (SSI...

  15. Scoring ultrasound synovitis in rheumatoid arthritis: a EULAR-OMERACT ultrasound taskforce-Part 1: definition and development of a standardised, consensus-based scoring system.

    Science.gov (United States)

    D'Agostino, Maria-Antonietta; Terslev, Lene; Aegerter, Philippe; Backhaus, Marina; Balint, Peter; Bruyn, George A; Filippucci, Emilio; Grassi, Walter; Iagnocco, Annamaria; Jousse-Joulin, Sandrine; Kane, David; Naredo, Esperanza; Schmidt, Wolfgang; Szkudlarek, Marcin; Conaghan, Philip G; Wakefield, Richard J

    2017-01-01

    To develop a consensus-based ultrasound (US) definition and quantification system for synovitis in rheumatoid arthritis (RA). A multistep, iterative approach was used to: (1) evaluate the baseline agreement on defining and scoring synovitis according to the usual practice of different sonographers, using both grey-scale (GS) (synovial hypertrophy (SH) and effusion) and power Doppler (PD), by reading static images and scanning patients with RA and (2) evaluate the influence of both the definition and acquisition technique on reliability followed by a Delphi exercise to obtain consensus definitions for synovitis, elementary components and scoring system. Baseline reliability was highly variable but better for static than dynamic images that were directly acquired and immediately scored. Using static images, intrareader and inter-reader reliability for scoring PD were excellent for both binary and semiquantitative (SQ) grading but GS showed greater variability for both scoring systems (κ ranges: -0.05 to 1 and 0.59 to 0.92, respectively). In patient-based exercise, both intraobserver and interobserver reliability were variable and the mean κ coefficients did not reach 0.50 for any of the components. The second step resulted in refinement of the preliminary Outcome Measures in Rheumatology synovitis definition by including the presence of both hypoechoic SH and PD signal and the development of a SQ severity score, depending on both the amount of PD and the volume and appearance of SH. A multistep consensus-based process has produced a standardised US definition and quantification system for RA synovitis including combined and individual SH and PD components. Further evaluation is required to understand its performance before application in clinical trials.

  16. Clinical Experience of the Treatment of Solitary Pulmonary Nodules with Da Vinci Surgical System

    Directory of Open Access Journals (Sweden)

    Xiangdong TONG

    2014-07-01

    Full Text Available Background and objective A solitary pulmonary nodule (SPN is defined as a round intraparenchimal lung lesion less than 3 cm in size, not associated with atelectasis or adenopathy. The aim of this study is to learn clinical experience of the treatment of SPN with Da Vinci Surgical System. Methods A total of 9 patients with solitary pulmonary nodules (SPN less than 3 cm in diameter was treated with Da Vinci Surgical System (Intuitive Surgical, California in thoracic surgery department from General Hospital of Shenyang Militrary Region from November 2011 to March 2014. This group of patients included 3 males and 6 females, and the mean age was 51±9.9 yr (range: 41-74 yr. Most of the patients were no obvious clinical symptoms (7 cases were found by physical examination, others were with cough and expectoration. Their median medical history was 12 mo (range: 4 d-3 yr. All the lesions of patients were peripheral pulmonary nodules and the mean diameter of those was (1.4±0.6 cm(range: 0.8-2.8 cm. Wedge-shaped resection or lobectomy was performed depending on the result of rapid pathology and systemic lymph node dissection was done for malignant leision. We used general anesthesis with double lumens trachea cannula. We set the patients in lateral decubitus position with jackknife. The patient cart enter from top of the patient. The position of trocars would be set according to the position of lesion. A 12 mm incision was positioned at the 8th intercostal space in the posterior axillary line as vision port, and two 8 mm incisions were positioned at the 5th intercostal space between the anterior axillary line and midclavicular line, and the 8th infrascapular line as robotic instrument ports about 10 cm apart from the vision port. One additional auxiliary small incision for instrument without retracting ribs was set at the 7th intercostal space in the middle axillary line. Results There were 4 benign leisions and 5 malignancies identified. Wedge

  17. A high pulse repetition frequency ultrasound system for the ex vivo measurement of mechanical properties of crystalline lenses with laser-induced microbubbles interrogated by acoustic radiation force.

    Science.gov (United States)

    Yoon, Sangpil; Aglyamov, Salavat; Karpiouk, Andrei; Emelianov, Stanislav

    2012-08-07

    A high pulse repetition frequency ultrasound system for an ex vivo measurement of mechanical properties of an animal crystalline lens was developed and validated. We measured the bulk displacement of laser-induced microbubbles created at different positions within the lens using nanosecond laser pulses. An impulsive acoustic radiation force was applied to the microbubble, and spatio-temporal measurements of the microbubble displacement were assessed using a custom-made high pulse repetition frequency ultrasound system consisting of two 25 MHz focused ultrasound transducers. One of these transducers was used to emit a train of ultrasound pulses and another transducer was used to receive the ultrasound echoes reflected from the microbubble. The developed system was operating at 1 MHz pulse repetition frequency. Based on the measured motion of the microbubble, Young's moduli of surrounding tissue were reconstructed and the values were compared with those measured using the indentation test. Measured values of Young's moduli of four bovine lenses ranged from 2.6 ± 0.1 to 26 ± 1.4 kPa, and there was good agreement between the two methods. Therefore, our studies, utilizing the high pulse repetition frequency ultrasound system, suggest that the developed approach can be used to assess the mechanical properties of ex vivo crystalline lenses. Furthermore, the potential of the presented approach for in vivo measurements is discussed.

  18. The Settings, Pros and Cons of the New Surgical Robot da Vinci Xi System for Transoral Robotic Surgery (TORS): A Comparison With the Popular da Vinci Si System.

    Science.gov (United States)

    Kim, Da Hee; Kim, Hwan; Kwak, Sanghyun; Baek, Kwangha; Na, Gina; Kim, Ji Hoon; Kim, Se Heon

    2016-10-01

    The da Vinci system (da Vinci Surgical System; Intuitive Surgical Inc.) has rapidly developed in several years from the S system to the Si system and now the Xi System. To investigate the surgical feasibility and to provide workflow guidance for the newly released system, we used the new da Vinci Xi system for transoral robotic surgery (TORS) on a cadaveric specimen. Bilateral supraglottic partial laryngectomy, hypopharyngectomy, lateral oropharyngectomy, and base of the tongue resection were serially performed in search of the optimal procedures with the new system. The new surgical robotic system has been upgraded in all respects. The telescope and camera were incorporated into one system, with a digital end-mounted camera. Overhead boom rotation allows multiquadrant access without axis limitation, the arms are now thinner and longer with grabbing movements for easy adjustments. The patient clearance button dramatically reduces external collisions. The new surgical robotic system has been optimized for improved anatomic access, with better-equipped appurtenances. This cadaveric study of TORS offers guidance on the best protocol for surgical workflow with the new Xi system leading to improvements in the functional results of TORS.

  19. Abortion - surgical

    Science.gov (United States)

    Suction curettage; Surgical abortion; Elective abortion - surgical; Therapeutic abortion - surgical ... Surgical abortion involves dilating the opening to the uterus (cervix) and placing a small suction tube into the uterus. ...

  20. Image reporting and characterization system for ultrasound features of thyroid nodules: Multicentric Korean retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Jin Young [Dept. of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of); Jung, In Kyung [Dept. of Biostatistics, Yonsei University College of Medicine, Seoul (Korea, Republic of); Beak, Jung Hwan [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seou (Korea, Republic of); and others

    2013-01-15

    The objective of this retrospective study was to develop and validate a simple diagnostic prediction model by using ultrasound (US) features of thyroid nodules obtained from multicenter retrospective data. Patient data were collected from 20 different institutions and the data included 2000 thyroid nodules from 1796 patients. For developing a diagnostic prediction model to estimate the malignant risk of thyroid nodules using suspicious malignant US features, we developed a training model in a subset of 1402 nodules from 1260 patients. Several suspicious malignant US features were evaluated to create the prediction model using a scoring tool. The scores for such US features were estimated by calculating odds ratios, and the risk score of malignancy for each thyroid nodule was defined as the sum of these individual scores. Later, we verified the usefulness of developed scoring system by applying into the remaining 598 nodules from 536 patients. Among 2000 tumors, 1268 were benign and 732 were malignant. In our multiple regression analysis models, the following US features were statistically significant for malignant nodules when using the training data set: hypoechogenicity, marked hypoechogenicity, non-parallel orientation, microlobulated or spiculated margin, ill-defined margins, and microcalcifications. The malignancy rate was 7.3% in thyroid nodules that did not have suspicious-malignant features on US. Area under the receiver operating characteristic (ROC) curve was 0.867, which shows that the US risk score help predict thyroid malignancy well. In the test data set, the malignancy rates were 6.2% in thyroid nodules without malignant features on US. Area under the ROC curve of the test set was 0.872 when using the prediction model. The predictor model using suspicious malignant US features may be helpful in risk stratification of thyroid nodules.

  1. System-Level Design of an Integrated Receiver Front End for a Wireless Ultrasound Probe.

    Science.gov (United States)

    Di Ianni, Tommaso; Hemmsen, Martin Christian; Llimos Muntal, Pere; Jorgensen, Ivan Harald Holger; Jensen, Jorgen Arendt

    2016-11-01

    In this paper, a system-level design is presented for an integrated receive circuit for a wireless ultrasound probe, which includes analog front ends and beamformation modules. This paper focuses on the investigation of the effects of architectural design choices on the image quality. The point spread function is simulated in Field II from 10 to 160 mm using a convex array transducer. A noise analysis is performed, and the minimum signal-to-noise ratio (SNR) requirements are derived for the low-noise amplifiers (LNAs) and A/D converters (ADCs) to fulfill the design specifications of a dynamic range of 60 dB and a penetration depth of 160 mm in the B-mode image. Six front-end implementations are compared using Nyquist-rate and Σ∆ modulator ADCs. The image quality is evaluated as a function of the depth in terms of lateral full-width at half-maximum (FWHM) and -12-dB cystic resolution (CR). The designs that minimally satisfy the specifications are based on an 8-b 30-MSPS Nyquist converter and a single-bit third-order 240-MSPS Σ∆ modulator, with an SNR for the LNA in both cases equal to 64 dB. The mean lateral FWHM and CR are 2.4% and 7.1% lower for the Σ∆ architecture compared with the Nyquist-rate one. However, the results generally show minimal differences between equivalent architectures. Advantages and drawbacks are finally discussed for the two families of converters.

  2. Measurement of cervical range of motion pattern during cyclic neck movement by an ultrasound-based motion system.

    Science.gov (United States)

    Wang, Shwu-Fen; Teng, Chin-Chih; Lin, Kwan-Hwa

    2005-02-01

    Goniometers and radiographic imaging have been used to measure active or passive cervical range of motion (ROM) in asymptomatic adults. However, the ultrasound-based coordinate measuring system (CMS) can measure continuous neck motion in three dimensions. The aims of this investigation are to evaluate the reliability and validity of ultrasound-based CMS (Zebris, CMS 70P), and to compare the cervical ROM patterns of asymptomatic young and middle-aged adults during continuous neck motions in the three cardinal planes. The ROM reciprocal ratio was defined as the ratio of the ROM from neutral position in one direction versus that in the opposite direction at the same cardinal plane. This study demonstrated the high test-retest reliability and validity of CMS during cervical motion in Chinese participants. Middle-aged adults exhibit reduced ROM ratios in the sagittal and frontal planes. The advantages and limitations of the CMS measurement tool and the potential future applications are documented. The measurement of neck motion pattern by ultrasound-based CMS may provide information on the management of neck dysfunction during functional movements.

  3. Thyroid ultrasound

    OpenAIRE

    Vikas Chaudhary; Shahina Bano

    2013-01-01

    Thyroid ultrasonography has established itself as a popular and useful tool in the evaluation and management of thyroid disorders. Advanced ultrasound techniques in thyroid imaging have not only fascinated the radiologists but also attracted the surgeons and endocrinologists who are using these techniques in their daily clinical and operative practice. This review provides an overview of indications for ultrasound in various thyroid diseases, describes characteristic ultrasound findings in th...

  4. Ultrasound physics.

    Science.gov (United States)

    Shriki, Jesse

    2014-01-01

    Bedside ultrasound has become an important modality for obtaining critical information in the acute care of patients. It is important to understand the physics of ultrasound in order to perform and interpret images at the bedside. The physics of both continuous wave and pulsed wave sound underlies diagnostic ultrasound. The instrumentation, including transducers and image processing, is important in the acquisition of appropriate sonographic images. Understanding how these concepts interplay with each other enables practitioners to obtain the best possible images.

  5. Diuretic Agent and Normal Saline Infusion Technique for Ultrasound-Guided Percutaneous Nephrostomies in Nondilated Pelvicaliceal Systems

    Energy Technology Data Exchange (ETDEWEB)

    Yagci, Cemil, E-mail: cemil.yagci@medicine.ankara.edu.tr; Ustuner, Evren, E-mail: evrenustuner@hotmail.com; Atman, Ebru Dusunceli, E-mail: ebrumd2001@yahoo.com [Ankara University, Department of Radiology, School of Medicine (Turkey); Baltaci, Sumer, E-mail: sbaltaci@hotmail.com [Ankara University, Department of Urology, School of Medicine (Turkey); Uzun, Caglar, E-mail: cuzun77@yahoo.com; Akyar, Serdar, E-mail: yusuf.s.akyar@medicine.ankara.edu.tr [Ankara University, Department of Radiology, School of Medicine (Turkey)

    2013-04-15

    Percutaneous nephrostomy (PCN) in a nondilated pelvicaliceal system is technically challenging. We describe an effective method to achieve transient dilatation of the pelvicaliceal system via induction of diuresis using infusion of a diuretic agent in normal saline, therefore allowing easier access to the pelvicaliceal system. Under real-time ultrasound guidance, the technique had been tested in 22 nephrostomies with nondilated system (a total of 20 patients with 2 patients having bilateral nephrostomies) during a 5-year period. Patients were given 40 mg of furosemide in 250 ml of normal saline solution intravenously by rapid infusion. As soon as maximum calyceal dilatation of more than 5 mm was observed, which is usually 15 min later after the end of rapid infusion, patients were positioned obliquely, and PCN procedure under ultrasound guidance was performed. The procedure was successful in 19 of the nephrostomies in 17 patients with a success rate of 86.36 % per procedure and 85 % per patient in nondilated pelvicaliceal systems. No major nephrostomy-, drug-, or technique-related complications were encountered. The technique failed to work in three patients due to the presence of double J catheters and preexisting calyceal perforation which avoided transient dilation of the pelvicaliceal system with diuresis. Diuretic infusion in saline is a feasible and effective method for PCN in nondilated pelvicaliceal systems.

  6. Surgical treatment of female stress urinary incontinence with the Gynecare TVT Secur™ System – preliminary report

    Directory of Open Access Journals (Sweden)

    Włodzimierz Baranowski

    2010-02-01

    Full Text Available Introduction: Sling procedures were first introduced over 100 years ago in the treatment of stress urinaryincontinence. Since then they have evolved to become less invasive and safer. The sling procedure using theGynecare TVT Secur™ system is a new therapeutic option for women with stress urinary incontinence.Objectives: To evaluate the efficacy and safety of Gynecare TVT Secur™ in the surgical treatment of stressurinary incontinence in women. Material and methods: The study comprised consecutive female patients admitted to the Department ofGynaecology and Gynaecological Oncology of the Military Institute of Health Services in Warsaw, Poland, whohad been qualified for surgical treatment of stress urinary incontinence on the basis of physical signs and symptomsand the findings of a urodynamic study. The procedure was performed using the Gynecare TVT Secur™system with tapes introduced in an H- or U-shape mode. Results: Between October 2006 and September 2009, 77 sling procedures using the Gynecare TVT Secur™system were performed in women with stress urinary incontinence. Their mean age was 55.1 (30-76 years, meanBMI 28.5 (20.2-43.8 kg/m2. Sixty-nine implants were positioned in H-shape mode, 8 in U-shape mode. Fortyninewomen (63.6% were menopausal, 14 (18.2% previously had three or more natural deliveries, 13 (16.8%had a history of gynaecological surgeries. Thirty-one procedures were performed under general anaesthesia and46 under local anaesthesia. The mean duration of the surgery was 9 (4-42 minutes. It was possible to dischargefifty-seven (74% women on the day of the surgery. Urine retention was observed only in 1 (1.7% woman. Noother complications were recorded. Conclusions: The surgical treatment of urinary incontinence with sling procedures using the Gynecare TVTSecur™ system shows good immediate efficacy and safety. Considering this as well as the short duration ofthe procedure and its good tolerability under local anaesthesia, use

  7. VR-based training and assessment in ultrasound-guided regional anesthesia: from error analysis to system design.

    LENUS (Irish Health Repository)

    2011-01-01

    If VR-based medical training and assessment is to improve patient care and safety (i.e. a genuine health gain), it has to be based on clinically relevant measurement of performance. Metrics on errors are particularly useful for capturing and correcting undesired behaviors before they occur in the operating room. However, translating clinically relevant metrics and errors into meaningful system design is a challenging process. This paper discusses how an existing task and error analysis was translated into the system design of a VR-based training and assessment environment for Ultrasound Guided Regional Anesthesia (UGRA).

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) ...

  9. Systemic Inflammatory Reaction in Females with Severe Gestosis During Surgical Delivery

    Directory of Open Access Journals (Sweden)

    I. V. Mikhno

    2007-01-01

    Full Text Available Objective: to study the impact the impact of surgical delivery on the time course of changes in the concentration of tumor necrosis factor-а (TNF-а, interleukin (IL-1/8, y-interferon, IL-4, IL-6, IL-10, and neopterin in the venous blood of women with severe gestosis and to develop a method for correcting a perioperative systemic inflammatory reaction (SIR.Subjects and methods: 89 females in whom surgical delivery had been performed under spinal anesthesia were examined. A control group comprised 30 females with uncomplicated pregnancy; Group 1 included 29 females with severe gestosis; Group 2 consisted of 30 females with severe gestosis to whom the developed method of perioperative SIR correction with dexametha-sone and pentoxyphylline was applied. Solid-phase enzyme immunoassay was used to determine the peripheral blood level of the cytokines and neopterin. The study was conducted in the following steps: 1 before surgery; 2 during surgery (after aponeurosis suturing, 3, 4, and 5 on days 1, 3, and 5 postoperatively, respectively.Results. In females with uncomplicated pregnancy, surgical delivery was accompanied by increases in the concentrations of IL-1/8 and neopterin. This reaction was limited by the increased synthesis of IL-10. Beginning with the third postoperative day, there was a reduction in the level of proinflammatory cytokines. Significantly elevated venous blood concentrations of y-interferon, IL-1/8, TNF-а, IL-6, and decreased levels of anti-inflammatory cytokines, such as IL-10 and IL-4, were detectable in pregnant females with severe gestosis. Against the above background, surgical delivery caused an increase in the synthesis of proinflammatory cytokines and neopterin with the high level being within 5 postoperative days. The developed method for correction of perioperative SIR in females with severe gestosis lowered the concentrations of y-interferon, IL-1/8, TNF-а, IL-6, and neopterin and promoted the recovery of cytokine

  10. Surgical phantom for off-pump mitral valve replacement

    Science.gov (United States)

    McLeod, A. Jonathan; Moore, John; Guiraudon, Gerard M.; Jones, Doug L.; Campbell, Gordon; Peters, Terry M.

    2011-03-01

    Off-pump, intracardiac, beating heart surgery has the potential to improve patient outcomes by eliminating the need for cardiopulmonary bypass and aortic cross clamping but it requires extensive image guidance as well as the development of specialized instrumentation. Previously, developments in image guidance and instrumentation were validated on either a static phantom or in vivo through porcine models. This paper describes the design and development of a surgical phantom for simulating off-pump mitral valve replacement inside the closed beating heart. The phantom allows surgical access to the mitral annulus while mimicking the pressure inside the beating heart. An image guidance system using tracked ultrasound, magnetic instrument tracking and preoperative models previously developed for off-pump mitral valve replacement is applied to the phantom. Pressure measurements and ultrasound images confirm the phantom closely mimics conditions inside the beating heart.

  11. Drainage Systems Effect on Surgical Site Infection in Children with Perforated Appendicitis

    Directory of Open Access Journals (Sweden)

    Seref Kilic

    2016-09-01

    Full Text Available Aim: Effect of replacing open drainage system to closed drainage system on surgical site infection (SSI in children operated for perforated appendicitis was evaluated. Material and Method: Hospital files and computer records of perforated appendicitis cases operated in 2004-2010 were evaluated retrospectively. Open drainage systems were used for 70 in cases (group I and closed systems were used in the others (group II. Results: Eleven of SSI cases had superficial infection and 3 had the organ/space infection. SSI rate was 15.7% for group I and 7.5% for the group II. The antibiotic treatment length was 7.5 ± 3.4 days for group I and 6.4 ± 2.2 days for group II and the difference between groups was not statistically significant. Hospitalization length for group I was 8.2 ± 3.1 days and 6.8 ± 1.9 days for group II and the difference was statistically significant. Discussion: SSI is an important problem increasing morbidity and treatment costs through increasing hospitalization and antibiotic treatment length. Open drainage system used in operation in patients with perforated appendicitis leads an increased frequency of SSI when compared to the closed drainage system. Thus, closed drainage systems should be preferred in when drainage is necessary in operations for perforated appendicitis in children.

  12. Carotid Ultrasound Imaging

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Ultrasound - Carotid Carotid ultrasound uses sound waves to produce ... limitations of Carotid Ultrasound Imaging? What is Carotid Ultrasound Imaging? Ultrasound is safe and painless, and produces ...

  13. General Ultrasound Imaging

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce pictures ... limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and painless, and produces ...

  14. Venous Ultrasound (Extremities)

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Ultrasound - Venous (Extremities) Venous ultrasound uses sound waves to ... limitations of Venous Ultrasound Imaging? What is Venous Ultrasound Imaging? Ultrasound is safe and painless, and produces ...

  15. A framework for human spine imaging using a freehand 3D ultrasound system

    NARCIS (Netherlands)

    Purnama, Ketut E.; Wilkinson, Michael. H. F.; Veldhuizen, Albert G.; van Ooijen, Peter. M. A.; Lubbers, Jaap; Burgerhof, Johannes G. M.; Sardjono, Tri A.; Verkerke, Gijbertus J.

    2010-01-01

    The use of 3D ultrasound imaging to follow the progression of scoliosis, i.e., a 3D deformation of the spine, is described. Unlike other current examination modalities, in particular based on X-ray, its non-detrimental effect enables it to be used frequently to follow the progression of scoliosis wh

  16. Assessment of a new e-learning system on thorax, trachea, and lung ultrasound.

    Science.gov (United States)

    Cuca, Colleen; Scheiermann, Patrick; Hempel, Dorothea; Via, Gabriele; Seibel, Armin; Barth, Magnus; Hirche, Tim O; Walcher, Felix; Breitkreutz, Raoul

    2013-01-01

    Background. Lung ultrasound has become an emerging tool in acute and critical care medicine. Combined theoretical and hands-on training has been required to teach ultrasound diagnostics. Current computer technology allows for display, explanation, and animation of information in a remote-learning environment. Objective. Development and assessment of an e-learning program for lung ultrasound. Methods. An interactive online tutorial was created. A prospective learning success study was conducted with medical students using a multiple-choice test (Trial A). This e-learning program was used as preparation for a certified course followed by an evaluation of trained doctors (Trial B) by linear analogue scales. Pretests were compared with postcourse tests and sustainability tests as well as a posttest of a one-day custom classroom training. Results. In Trial A, during the learning success study (n = 29), the increase of correct answers was 11.7 to 17/20 in the post-test and to 16.6/20 in the sustainability test (relative change 45.1%, P < 0.0001). E-learning almost equalled scores of classroom-based training regarding gain and retention of factual knowledge. In Trial B, nineteen participating doctors found a 79.5% increase of knowledge (median, 95% CI: 69%; 88%). Conclusion. The basics of lung ultrasound can be taught in a highly effective manner using e-learning.

  17. Assessment of a New E-Learning System on Thorax, Trachea, and Lung Ultrasound

    Directory of Open Access Journals (Sweden)

    Colleen Cuca

    2013-01-01

    Full Text Available Background. Lung ultrasound has become an emerging tool in acute and critical care medicine. Combined theoretical and hands-on training has been required to teach ultrasound diagnostics. Current computer technology allows for display, explanation, and animation of information in a remote-learning environment. Objective. Development and assessment of an e-learning program for lung ultrasound. Methods. An interactive online tutorial was created. A prospective learning success study was conducted with medical students using a multiple-choice test (Trial A. This e-learning program was used as preparation for a certified course followed by an evaluation of trained doctors (Trial B by linear analogue scales. Pretests were compared with postcourse tests and sustainability tests as well as a posttest of a one-day custom classroom training. Results. In Trial A, during the learning success study (n=29, the increase of correct answers was 11.7 to 17/20 in the post-test and to 16.6/20 in the sustainability test (relative change 45.1%, P<0.0001. E-learning almost equalled scores of classroom-based training regarding gain and retention of factual knowledge. In Trial B, nineteen participating doctors found a 79.5% increase of knowledge (median, 95% CI: 69%; 88%. Conclusion. The basics of lung ultrasound can be taught in a highly effective manner using e-learning.

  18. Chest Ultrasound Integrated Teaching of Respiratory System Physiology to Medical Students: A First Experience

    Science.gov (United States)

    Paganini, M.; Rubini, A.

    2015-01-01

    Ultrasound imaging is a useful diagnostic technique that has spread among several different medical specialties within the last few years. Initially restricted to radiology, cardiology, obstetrics, and gynecology, today it is widely used by many specialists, especially in critical care. New graduate physicians will need to be comfortable with…

  19. Enhanced gene expression of systemically administered plasmid DNA inthe liver with therapeutic ultrasound and microbubbles

    NARCIS (Netherlands)

    Raju, B.I.; Leyvi, E.; Seip, R.; Sethuraman, S.; Luo, X.; Bird, A.; Li, S.; Koeberl, D.

    2012-01-01

    Ultrasound mediated delivery (USMD) of novel therapeutic agents in the presence of microbubbles is a potentially safe and effective method for gene therapy offering many desired characteristics such as low toxicity, potential for repeated treatment, and organ specificity.In this study we tested the

  20. Compact and user-friendly ultrasound acquisition systems optimized for field recording

    Directory of Open Access Journals (Sweden)

    Specht Raimund

    2004-01-01

    Full Text Available A compact and rugged hardware interface for laptop-based ultrasound recording in the field has been developed. The versatile devices overcome the limitations and drawbacks of previously available solutions. The accompanying recording software enables flexible hard disk recording for both manual and automated operation.

  1. Counterbalancing the use of ultrasound contrast agents by a cavitation-regulated system.

    Science.gov (United States)

    Desjouy, C; Fouqueray, M; Lo, C W; Muleki Seya, P; Lee, J L; Bera, J C; Chen, W S; Inserra, C

    2015-09-01

    The stochastic behavior of cavitation can lead to major problems of initiation and maintenance of cavitation during sonication, responsible of poor reproducibility of US-induced bioeffects in the context of sonoporation for instance. To overcome these disadvantages, the injection of ultrasound contrast agents as cavitation nuclei ensures fast initiation and lower acoustic intensities required for cavitation activity. More recently, regulated-cavitation devices based on the real-time modulation of the applied acoustic intensity have shown their potential to maintain a stable cavitation state during an ultrasonic shot, in continuous or pulsed wave conditions. In this paper is investigated the interest, in terms of cavitation activity, of using such regulated-cavitation device or injecting ultrasound contrast agents in the sonicated medium. When using fixed applied acoustic intensity, results showed that introducing ultrasound contrast agents increases reproducibility of cavitation activity (coefficient of variation 62% and 22% without and with UCA, respectively). Moreover, the use of the regulated-cavitation device ensures a given cavitation activity (coefficient of variation less 0.4% in presence of UCAs or not). This highlights the interest of controlling cavitation over time to free cavitation-based application from the use of UCAs. Interestingly, during a one minute sonication, while ultrasound contrast agents progressively disappear, the regulated-cavitation device counterbalance their destruction to sustain a stable inertial cavitation activity.

  2. A framework for human spine imaging using a freehand 3D ultrasound system

    NARCIS (Netherlands)

    Purnama, Ketut E.; Wilkinson, Michael. H. F.; Veldhuizen, Albert G.; van Ooijen, Peter. M. A.; Lubbers, Jaap; Burgerhof, Johannes G. M.; Sardjono, Tri A.; Verkerke, Gijbertus J.

    2010-01-01

    The use of 3D ultrasound imaging to follow the progression of scoliosis, i.e., a 3D deformation of the spine, is described. Unlike other current examination modalities, in particular based on X-ray, its non-detrimental effect enables it to be used frequently to follow the progression of scoliosis wh

  3. Ultrasound-Accelerated Thrombolysis in Patients With Intracardiac Thrombi: A Case Series.

    Science.gov (United States)

    Yadlapati, Ajay; Sweis, Ranya; Schimmel, Daniel

    2016-03-01

    We describe a case series of 3 patients presenting with intracardiac thrombi treated with standard anticoagulation therapy and intervention with ultrasound-accelerated thrombolysis therapy. Right-sided intracardiac thrombi portend significant mortality due to their susceptibility for embolization and pulmonary embolus despite the continuation of current standard of therapy of parenteral anticoagulation and surgical embolectomy if warranted. We demonstrate the safety and clinical efficacy of ultrasound-accelerated thrombolysis therapy with the EkoSonic Endovascular System infusion catheter system (EKOS Corporation) and highlight its use in resolving intracardiac thrombi and impeding the propagation of pulmonary emboli.

  4. Determining the Learning Curve of Transcutaneous Laryngeal Ultrasound in Vocal Cord Assessment by CUSUM Analysis of Eight Surgical Residents: When to Abandon Laryngoscopy.

    Science.gov (United States)

    Wong, Kai-Pun; Lang, Brian Hung-Hin; Lam, Shi; Au, Kin-Pan; Chan, Diane Toi-yin; Kotewall, Nicholas Clarence

    2016-03-01

    Transcutaneous laryngeal ultrasonography (TLUSG) is a promising alternative to laryngoscopy in vocal cords (VCs) assessment which might be challenging in the beginning. However, it remains unclear when an assessor can provide proficient TLUSG enough to abandon direct laryngoscopy . Eight surgical residents (SRs) without prior USG experience were recruited to determine the learning curve. After a standardized training program, SRs would perform 80 consecutive peri-operative VCs assessment using TLUSG. Performances of SRs were quantitatively evaluated by a composite performance score (lower score representing better performance) which comprised total examination time (in seconds), VCs visualization, and assessment accuracy. Cumulative sum (CUSUM) chart was then used to evaluate learning curve. Diagnostic accuracy and demographic data between every twentieth TLUSG were compared. 640 TLUSG examinations had been performed by 8 residents. 95.1% of VCs could be assessed by SRs. The CUSUM curve showed a rising pattern (learning phase) until 7th TLUSG and then flattened. The curve declined continuously after 42nd TLUSG (after reaching a plateau). Rates of assessable VCs were comparable in every twentieth cases performed. It took a longer time to complete TLUSG in 1st-20th than 21st-40th examinations. (45 vs. 32s, p = 0.001). Although statistically not significant, proportion of false-negative results was higher in 21st-40th (2.5%) than 1(st)-20th (0.6%), 41(st)-60th (0.7%), and 61(st)-80th (0.7%) TLUSG performed. After a short formal training, surgeons could master skill in TLUSG after seven examination and assess vocal cord function consistently and accurately after 40 TLUSG.

  5. Robot-assisted cardiac surgery using the da vinci surgical system: a single center experience.

    Science.gov (United States)

    Kim, Eung Re; Lim, Cheong; Kim, Dong Jin; Kim, Jun Sung; Park, Kay Hyun

    2015-04-01

    We report our initial experiences of robot-assisted cardiac surgery using the da Vinci Surgical System. Between February 2010 and March 2014, 50 consecutive patients underwent minimally invasive robot-assisted cardiac surgery. Robot-assisted cardiac surgery was employed in two cases of minimally invasive direct coronary artery bypass, 17 cases of mitral valve repair, 10 cases of cardiac myxoma removal, 20 cases of atrial septal defect repair, and one isolated CryoMaze procedure. Average cardiopulmonary bypass time and average aorta cross-clamping time were 194.8±48.6 minutes and 126.1±22.6 minutes in mitral valve repair operations and 132.0±32.0 minutes and 76.1±23.1 minutes in myxoma removal operations, respectively. During atrial septal defect closure operations, the average cardiopulmonary bypass time was 128.3±43.1 minutes. The median length of stay was between five and seven days. The only complication was that one patient needed reoperation to address bleeding. There were no hospital mortalities. Robot-assisted cardiac surgery is safe and effective for mitral valve repair, atrial septal defect closure, and cardiac myxoma removal surgery. Reducing operative time depends heavily on the experience of the entire robotic surgical team.

  6. Ultrasound transmission attenuation tomography using energy-scaled amplitude ratios

    Science.gov (United States)

    Chen, Ting; Shin, Junseob; Huang, Lianjie

    2016-04-01

    Ultrasound attenuation of breast tumors is related to their types and pathological states, and can be used to detect and characterize breast cancer. Particularly, ultrasound scattering attenuation can infer the margin properties of breast tumors. Ultrasound attenuation tomography quantitatively reconstructs the attenuation properties of the breast. Our synthetic-aperture breast ultrasound tomography system with two parallel transducer arrays records both ultrasound reflection and transmission signals. We develop an ultrasound attenuation tomography method using ultrasound energy-scaled amplitude decays of ultrasound transmission signals and conduct ultrasound attenuation tomography using a known sound-speed model. We apply our ultrasound transmission attenuation tomography method to a breast phantom dataset, and compare the ultrasound attenuation tomography results with conventional beamforming ultrasound images obtained using reflection signals. We show that ultrasound transmission attenuation tomography complements beamforming images in identifying breast lesions.

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Prostate ... imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also ...

  8. System Architecture of an Experimental Synthetic Aperture Real-Time Ultrasound System

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Hansen, Martin; Tomov, Borislav Gueorguiev

    2007-01-01

    , and focusing and summing of data. Each FPGA can perform 80 billion multiplications/s and the full system can perform 25,600 billion multiplications/s. The FPGAs are connected through multiple 3.2 Gbit Rocket 10 links, which makes it possible to send more than 1.6 GBytes/s of data between the FPGAs and between...

  9. A High-Frequency High Frame Rate Duplex Ultrasound Linear Array Imaging System for Small Animal Imaging

    Science.gov (United States)

    Zhang, Lequan; Xu, Xiaochen; Hu, Changhong; Sun, Lei; Yen, Jesse T.; Cannata, Jonathan M.; Shung, K. Kirk

    2010-01-01

    High-frequency (HF) ultrasound imaging has been shown to be useful for non-invasively imaging anatomical structures of the eye and small animals in biological and pharmaceutical research, achieving superior spatial resolution. Cardiovascular research utilizing mice requires not only real-time B-scan imaging, but also ultrasound Doppler to evaluate both anatomy and blood flow of the mouse heart. This paper reports the development of a high frequency ultrasound duplex imaging system capable of both B-mode imaging and Doppler flow measurements, using a 64-element linear array. The system included a HF pulsed-wave Doppler module, a 32-channel HF B-mode imaging module, a PC with a 200 MS/s 14-bit A/D card, and real-time LabView software. A 50dB signal-to-noise ratio (SNR) and a depth of penetration of larger than 12 mm were achieved using a 35 MHz linear array with 50 μm pitch. The two-way beam widths were determined to be 165 μm to 260 μm and the clutter energy to total energy ratio (CTR) were 9.1 dB to 12 dB, when the array was electronically focused at different focal points at depths from 4.8 mm to 9.6 mm. The system is capable of acquiring real-time B-mode images at a rate greater than 400 frames per second (fps) for a 4.8 × 13 mm field of view, using a 30 MHz 64-element linear array with 100 μm pitch. Sample in vivo cardiac high frame rate images and duplex images of mouse hearts are shown to assess its current imaging capability and performance for small animals. PMID:20639149

  10. Intraoperative Ultrasound Assisted Microsurgery Surgical Treatment for Deep Brain Tumors%术中超声辅助显微神经外科手术治疗脑深部肿瘤

    Institute of Scientific and Technical Information of China (English)

    戴兴; 晏子媛; 杨超

    2015-01-01

    目的:探讨术中超声辅助显微神经外科手术治疗脑深部肿瘤的临床价值。方法选择我院2009年10月至2014年7月收治的50例脑深部肿瘤患者的资料,均行显微神经外科手术治疗,术前进行颅脑核磁共振(MRI)检查,术中采用超声确定病变位置、病灶深度及与周围组织关系,行肿瘤切除术,对超声在显微神经外科手术中辅助定位脑深部肿瘤的价值进行评价。结果在本组50例患者中,胶质瘤32例,海绵状血管瘤8例,脉络膜乳头状瘤5例,脑膜瘤5例。50例患者肿瘤定位准确,瘤体完全切除,术后恢复良好。与术前MRI诊断相比较,术中超声实时瘤体体积与MRI结果基本一致,但超声有探测能力强、实时、随时探测的术中指导能力。结论颅脑深部肿瘤显微外科术中应用超声技术,具有图像实时可靠、定位准确的特点,对于提高肿瘤的全切率有积极意义。%Objective To discuss the intraoperative ultrasound assisted microsurgery surgical treatment the clinical value of deep brain tumor.Methods From October 2009 to July 2014 were 50 cases of patients with deep brain tumor information, both microscopic nerve surgery, preoperative brain magnetic resonance (MRI) examination, intraoperative using ultrasonic determine lesion location, the focal depth and the relationship with the surrounding tissue, tumor resection, auxiliary positioning of ultrasound in the micro neurosurgery to evaluate the value of the deep brain tumors.Results Gliomas in 50 cases patients, 32cases, 8 cases of cavernous hemangioma,5 cases of inverted papilloma of the choroid, 5 cases with meningioma. 50 cases of patients with tumor location accurate, tumors had complete resection, postoperative recovered well. Compared with the preoperative MRI diagnosis and intraoperative ultrasound real-time tumors volume and MR results are basically identical, but there are ultrasonic detection capability

  11. Towards MRI guided surgical manipulator.

    Science.gov (United States)

    Chinzei, K; Miller, K

    2001-01-01

    The advantages of surgical robots and manipulators are well recognized in the clinical and technical community. Precision, accuracy and the potential for telesurgery are the prime motivations in applying advanced robot technology in surgery. In this paper critical interactions between Magnetic Resonance Imaging equipment and mechatronic devices are discussed and a novel Magnetic Resonance compatible surgical robot is described. Experimental results of the effects from several passive (metallic materials) and active (ultrasound motors) mechanical elements are demonstrated. The design principles for Magnetic Resonance compatible robots are established and the compatibility of the proposed robot is assessed by comparing images taken with and without the robot's presence within Signa SP/I GE Medical Systems scanner. The results showed that, in principle, it is possible to construct precision mechatronic devices intended to operate inside MR scanner. Use of such a device will not cause image shift or significant degradation of signal-to-noise-ratio. An MR compatible surgical assist robot was designed and constructed. The robot is not affected by the presence of strong magnetic fields and is able to manoeuvre during imaging without compromising the quality of images. A novel image-guided robot control scheme was proposed. As a part of the control scheme, biomechanics-based organ deformation model was constructed and validated by in-vivo experiment. It has been recognised that for robust control of an image guided surgical robot the precise knowledge of the mechanical properties of soft organs operated on must be known. As an illustration, results in mathematical modelling and computer simulation of brain deformation are given. The novel MR compatible robot was designed to position and direct an axisymmetric tool, such as a laser pointer or a biopsy catheter. New Robot control system based on the prediction of soft organ deformation was proposed.

  12. Dimensional optimization of a minimally invasive surgical robot system based on NSGA-II algorithm

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2015-02-01

    Full Text Available Based on the proposed end-effector structure of a laparoscopic minimally invasive surgical manipulator, a dimensional optimization method is investigated to enlarge the motion range of the mechanical arm in the specific target area and reduce the collision among the mechanical arms simultaneously. Both the length of the kinematics links and the overall size of the integrated system are considered in the optimization process. The NSGA-II algorithm oriented to the multi-objective optimization is utilized to calculate the Pareto solution set of the objective function. Finally, the dependence of the evaluation indexes is analysed to filter the non-inferior set, which guarantees the selection of the optimization solution.

  13. Robotics and telecommunication systems to provide better access to ultrasound expertise in the OR.

    Science.gov (United States)

    Angelini, L; Papaspyropoulos, V

    2000-01-01

    Surgery has begun to evolve as a result of the intense use of technological innovations. The result of this is better services for patients and enormous opportunities for the producers of biomedical instruments. The surgeon and the technologist are fast becoming allies in applying the latest developments of robotics, image treatment, simulation, sensors and telecommunications to surgery, in particular to the emerging field of minimally-invasive surgery. Ultrasonography is at present utilised both for diagnostic and therapeutic purposes in various fields. Intraoperative US examination can be of primary importance, especially when dealing with space-occupying lesions. The widening use of minimally-invasive surgery has furthered the development of US for use during this type of surgery. The success of a US examination requires not only a correct execution of the procedure, but also a correct interpretation of the images. We describe two projects that combine robotics and telecommunication systems to provide better access to US expertise in the operating room. The Midstep project has as its object the realisation of two robotic arms, one for the distant control of the US probe during laparoscopic surgery and the second to perform tele-interventional US. The second project, part of the Strategic CNR Project-'Robotics in Surgery', involves the realisation of a common platform for tracking and targeting surgical instruments in video-assisted surgery.

  14. Ultrasound-mediated blood-brain barrier disruption for targeted drug delivery in the central nervous system

    Science.gov (United States)

    McDannold, Nathan; Zhang, Yongzhi; Power, Chanikarn; Arvanitis, Costas D.; Vykhodtseva, Natalia; Livingstone, Margaret

    2015-05-01

    The physiology of the vasculature in the central nervous system (CNS), which includes the blood-brain barrier (BBB) and other factors, complicates the delivery of most drugs to the brain. Different methods have been used to bypass the BBB, but they have limitations such as being invasive, non-targeted or requiring the formulation of new drugs. Focused ultrasound (FUS), when combined with circulating microbubbles, is a noninvasive method to locally and transiently disrupt the BBB at discrete targets. The method presents new opportunities for the use of drugs and for the study of the brain.

  15. The galenic venous system: Surgical anatomy and its angiographic and magnetic resonance venographic correlations

    Energy Technology Data Exchange (ETDEWEB)

    Kilic, Tuerker [Marmara University, Department of Neurosurgery, PK 53, Maltepe, 81532 Istanbul (Turkey) and Marmara University, Department of Anatomy, Istanbul (Turkey)]. E-mail: turkilic@tnn.net; Ozduman, Koray [Marmara University, Department of Neurosurgery, PK 53, Maltepe, 81532 Istanbul (Turkey); Cavdar, Safiye [Marmara University, Department of Anatomy, Istanbul (Turkey); Oezek, M. Memet [Marmara University, Department of Neurosurgery, PK 53, Maltepe, 81532 Istanbul (Turkey); Pamir, M. Necmettin [Marmara University, Department of Neurosurgery, PK 53, Maltepe, 81532 Istanbul (Turkey)

    2005-11-01

    Objective: This study aims at evaluating the adequacy of digital subtraction angiography and magnetic resonance venography in imaging of the galenic venous system for surgical planning of approaches to the pineal region. Anatomical dissections were carried out in 10 cadavers of several age groups and these were compared to imaging findings in 10 living subjects. Methods: The presence or absence of 10 predetermined veins or vein groupings belonging to the galenic venous system were prospectively analyzed in 10 cadaver dissections and imaging findings of 10 age matched human subjects. The studied vessels were the vein of galen, the internal cerebral veins, both basal vein of Rosenthals, internal occipital vein, occipitotemporal veins, precentral cerebellar veins, tectal veins, pineal veins, superior vermian veins (including superior cerebellar veins (SCVs)) and posterior pericallosal veins. Each of the subjects had both digital subtraction angiography and magnetic resonance venography studies performed. Diagnostic digital subtraction angiography was performed using the transfemoral route and the venous phase was used for the study. Magnetic resonance venography was performed in 1.5 T MRI equipment using the 2D-TOF sequence. All studies were reported to be normal. Results: There was wide variation in the anatomy of the galenic venous system. There were interpersonal, intrapersonal and age related variations. Both the digital subtraction angiography and the magnetic resonance venography were efficient at demonstrating large veins. However, smaller veins were less readily demonstrated in either study. The general sensitivities of the digital subtraction angiography and the magnetic resonance venography for the galenic venous system were 45.5% and 32.5%, respectively. Surgically important veins were missed in most studies. Conclusions: Anatomically, the galenic venous system is highly variable. This variability is caused by interpersonal, intrapersonal and age related

  16. Clinical application of a 3D ultrasound-guided prostate biopsy system.

    Science.gov (United States)

    Natarajan, Shyam; Marks, Leonard S; Margolis, Daniel J A; Huang, Jiaoti; Macairan, Maria Luz; Lieu, Patricia; Fenster, Aaron

    2011-01-01

    Prostate biopsy (Bx) has for 3 decades been performed in a systematic, but blind fashion using 2D ultrasound (US). Herein is described the initial clinical evaluation of a 3D Bx tracking and targeting device (Artemis; Eigen, Grass Valley, CA). Our main objective was to test accuracy of the new 3D method in men undergoing first and follow-up Bx to rule out prostate cancer (CaP). Patients in the study were men ages 35-87 years (66.1 ± 9.9), scheduled for Bx to rule out CaP, who entered into an IRB-approved protocol. A total of 218 subjects underwent conventional trans-rectal US (TRUS); the tracking system was then attached to the US probe; the prostate was scanned and a 3D reconstruction was created. All Bx sites were visualized in 3D and tracked electronically. In 11 men, a pilot study was conducted to test ability of the device to return a Bx to an original site. In 47 men, multi-parametric 3 Tesla MRI, incorporating T2-weighted images, dynamic contrast enhancement, and diffusion-weighted imaging, was performed in advance of the TRUS, allowing the stored MRI images to be fused with real-time US during biopsy. Lesions on MRI were delineated by a radiologist, assigned a grade of CaP suspicion, and fused into TRUS for biopsy targeting. 3D Bx tracking was completed successfully in 180/218 patients, with a success rate approaching 95% among the last 50 men. Average time for Bx with the Artemis device was 15 minutes with an additional 5 minutes for MRI fusion and Bx targeting. In the tracking study, an ability to return to prior Bx sites (n=32) within 1.2 ± 1.1 mm SD was demonstrated and was independent of prostate volume or location of Bx site. In the MRI fusion study, when suspicious lesions were targeted, a 33% Bx-positivity rate was found compared with a 7% positivity rate for systematic, nontargeted Bx (19/57 cores vs. 9/124 cores, P=0.03). Use of 3D tracking and image fusion has the potential to transform MRI into a clinical tool to aid biopsy and improve current

  17. Ultrasound and ultrasound-related techniques in endocrine diseases.

    Science.gov (United States)

    Trimboli, Pierpaolo; Dietrich, Christoph F; David, Emanuele; Mastroeni, Giampiero; Ventura Spagnolo, Orazio; Sidhu, Paul S; Letizia, Claudio; Messineo, Daniela; D'Ambrosio, Ferdinando; Radzina, Maija; Cantisani, Vito

    2017-09-05

    Ultrasound examination has become essential to evaluate morphology and size of several endocrine glands and detect the presence of lesions within these organs. Nevertheless, with the recent advances of ultrasound technology, we have opportunity to correlate the echostructure of thyroid, ovary, testis, parathyroids, etc. to their function. Thus, the ultrasound systems are in-office essential instruments for many clinical specialists. Herein we presented the most updated information about the use of ultrasound in specific endocrine-related issues, such as thyroid, parathyroid, adrenal gland, and testicle.

  18. Advances in ultrasound methods for high-resolution imaging of the cardiovascular system.

    Science.gov (United States)

    Wickline, S A

    1997-07-01

    Acoustic microscopy entails the use of high-frequency high-resolution ultrasound methods to produce images of sound waves reflected from or propagated through some tissue of interest. The image contrast depends on microscopic differences in the intrinsic material properties of the substance imaged, such as mass density or compressibility. Pathologic changes in cardiovascular tissues at the subcellular level can be observed with high-frequency acoustic imaging techniques, based on alterations in the structure, properties, and organization of cells and their surrounding matrix. Potential applications extend from delineation of cardiovascular development in experimental animals to clinical characterization of the composition of atherosclerotic lesions with intravascular ultrasound and estimation of the potential for plaque rupture and infarction. (Trends Cardiovasc Med 1997;7:168-174). © 1997, Elsevier Science Inc.

  19. Feasibility of Concurrent Treatment with the Scanning Ultrasound Reflector Linear Array System (SURLAS) and the Helical Tomotherapy System

    Science.gov (United States)

    Peñagarícano, José A.; Moros, Eduardo; Novák, Petr; Yan, Yulong; Corry, Peter

    2010-01-01

    Purpose To evaluate the feasibility of concurrent treatment with the Scanning Ultrasound Reflector Linear Array System (SURLAS) and helical tomotherapy (HT) intensity modulated radiation therapy (IMRT). Methods The SURLAS was placed on a RANDO phantom simulating a patient with superficial or deep recurrent breast cancer. A Megavoltage CT (MVCT) of the phantom with and without the SURLAS was obtained in the HT system. MVCT images with the SURLAS were obtained for two configurations: i) with the SURLAS' long axis parallel and ii) perpendicular to the longitudinal axis of the phantom. The MVCT simulation data set was then transferred to a radiation therapy planning station. Organs at risk (OAR) were contoured including the lungs, heart, abdomen and spinal cord. The metallic parts of the SURLAS were contoured as well and constraints were assigned to completely or directionally block radiation through them. The MVCT-simulation data set and regions of interest (ROI) files were subsequently transferred to the HT planning station. Several HT plans were obtained with optimization parameters that are usually used in the clinic. For comparison purposes, planning was also performed without the SURLAS on the phantom. Results All plans with the SURLAS on the phantom showed adequate dose covering 95% of the planning target volume (PTV D95%), average dose and coefficient of variation of the planning target volume (PTV) dose distribution regardless of the SURLAS' orientation with respect to the RANDO phantom. Likewise, all OAR showed clinically acceptable dose values. Spatial dose distributions and dose-volume histogram (DVH) evaluation showed negligible plan degradation due to the presence of the SURLAS. Beam-on time varied depending on the selected optimization parameters. Conclusion From the perspective of the radiation dosage, concurrent treatment with the SURLAS and HT IMRT is feasible as demonstrated by the obtained clinically acceptable treatment plans. In addition, proper

  20. Ultrasound Location of Misplaced Levonorgestrel Releasing Intrauterine System (LNG-IUS) – is it easy?

    Science.gov (United States)

    Gowri, Vaidyanathan; Mathew, Mariam

    2009-01-01

    The Levonorgestrel intrauterine device (LNG-IUD) is a hormone-containing device licensed for treatment of menorrhagia and contraception. Though complications such as perforation have been reported similar to other non-hormonal intrauterine devices, the diagnosis of such complications is difficult with this device because the LNG-IUD has a different ultrasound appearance compared to copper devices and these case reports are intended to emphasize this point. PMID:22303513

  1. Ultrasound Location of Misplaced Levonorgestrel Releasing Intrauterine System (LNG-IUS) - is it easy?

    Science.gov (United States)

    Gowri, Vaidyanathan; Mathew, Mariam

    2009-01-01

    The Levonorgestrel intrauterine device (LNG-IUD) is a hormone-containing device licensed for treatment of menorrhagia and contraception. Though complications such as perforation have been reported similar to other non-hormonal intrauterine devices, the diagnosis of such complications is difficult with this device because the LNG-IUD has a different ultrasound appearance compared to copper devices and these case reports are intended to emphasize this point.

  2. Cranial Ultrasound/Head Ultrasound

    Science.gov (United States)

    ... sickle cell disease. It is also used to measure conditions affecting blood flow to and within the brain, such as: Stenosis : ... saved. Doppler ultrasound, a special application of ultrasound, measures ... represent the flow of blood through the blood vessels. top of ...

  3. Experience in the diagnostic and surgical treatment of pancreatic pseudocysts

    Directory of Open Access Journals (Sweden)

    N. G. Golovko

    2015-10-01

    Full Text Available Actuality. Problem of surgical treatment of pancreatic pseudocysts is actual and debatable. The incidence of pancreatic pseudocysts is 0.5–1 per 100 000 adults per year, and in the overall incidence it reaches 1.6% –4.5%. Aim. Surgical treatment results of 34 patients with pancreatic pseudocysts were analyzed to improve results of diagnostic and surgical management of pancreatic pseudocests. Methods and results. Ultrasound scan combined with computer tomography were used for pancreatic pseudocysts diagnostic. Pancreatic pseudocysts surgical treatment was performed by minimally invasive percutaneous techniques and laparotomic surgery. Laparotomy operations were performed in 27 patients. The structure of operations was follow: external drainage of pseudocysts - 11 patients, 2 of them by minilaparotomy access, pseudocyst jejunostomy by Roux – 9 patients, pseudocyst jejunostomy with entero-enteroanastamosis by Brown – 3 patients, pseudocyst gastrostomy and pseudocyst duodenostomy – in 2 patients. Percutaneous external drainage of pancreatic pseudocysts under ultrasound control was performed in 7 patients. Indications for external percutaneous needle drainage of pancreatic pseudocysts under ultrasound control were: presence of a secure acoustic windows, lack of communication with the pancreatic pseudocysts ductal system, pseudocyst cavity diameter greater than 60 mm with wall thickness more than 3–4 mm, presence of the severe comorbidity and high operational and anesthetic risk (III–IV class ASA. Conclusions. Analysis of early treatment results (3–6 months found that pancreatic pseudocysts minimally invasive percutaneous puncture external drainage use in combination with ultrasound control, in addition to laparotomic operation, allows to achieve excellent and good results in 91.1% of patients.

  4. Development of estimation system of knee extension strength using image features in ultrasound images of rectus femoris

    Science.gov (United States)

    Murakami, Hiroki; Watanabe, Tsuneo; Fukuoka, Daisuke; Terabayashi, Nobuo; Hara, Takeshi; Muramatsu, Chisako; Fujita, Hiroshi

    2016-04-01

    The word "Locomotive syndrome" has been proposed to describe the state of requiring care by musculoskeletal disorders and its high-risk condition. Reduction of the knee extension strength is cited as one of the risk factors, and the accurate measurement of the strength is needed for the evaluation. The measurement of knee extension strength using a dynamometer is one of the most direct and quantitative methods. This study aims to develop a system for measuring the knee extension strength using the ultrasound images of the rectus femoris muscles obtained with non-invasive ultrasonic diagnostic equipment. First, we extract the muscle area from the ultrasound images and determine the image features, such as the thickness of the muscle. We combine these features and physical features, such as the patient's height, and build a regression model of the knee extension strength from training data. We have developed a system for estimating the knee extension strength by applying the regression model to the features obtained from test data. Using the test data of 168 cases, correlation coefficient value between the measured values and estimated values was 0.82. This result suggests that this system can estimate knee extension strength with high accuracy.

  5. The Use of a Novel Ultrasound Guidance System for Real-time Central Venous Cannulation: Safety and Efficacy

    Directory of Open Access Journals (Sweden)

    Robinson M. Ferre

    2014-07-01

    Full Text Available Introduction: Real-time ultrasound guidance is considered to be the standard of care for central venous access for non-emergent central lines. However, adoption has been slow, in part because of the technical challenges and time required to become proficient. The AxoTrack® system (Soma Access Systems, Greenville, SC is a novel ultrasound guidance system recently cleared for human use by the United States Food and Drug Administration (FDA. Methods: After FDA clearance, the AxoTrack® system was released to three hospitals in the United States. Physicians and nurse practitioners who work in the intensive care unit or emergency department and who place central venous catheters were trained to use the AxoTrack® system. De-identified data about central lines placed in living patients with the AxoTrack® system was prospectively gathered at each of the three hospitals for quality assurance purposes. After institutional review board approval, we consolidated the data for the first five months of use for retrospective review. Results: The AxoTrack® system was used by 22 different health care providers in 50 consecutive patients undergoing central venous cannulation (CVC from September 2012 to February 2013. All patients had successful CVC with the guidance of the AxoTrack® system. All but one patient (98% had successful cannulation on the first site attempted. There were no reported complications, including pneumothorax, hemothorax, arterial puncture or arterial cannulation. Conclusion: The AxoTrack® system was a safe and effective means of CVC that was used by a variety of health care practitioners. [West J Emerg Med. 2014;15(4:536-540.

  6. Validation of a whole slide imaging system for primary diagnosis in surgical pathology: A community hospital experience

    OpenAIRE

    Buck, Thomas P.; Rebecca Dilorio; Lauren Havrilla; Dennis G O′Neill

    2014-01-01

    Guidelines for validating whole slide imaging (WSI) for primary diagnosis in surgical pathology have been recommended by an expert panel commissioned by the College of American Pathologists. The implementation of such a system using these validation guidelines has not been reported from the community hospital setting. The objective was to implement a WSI system, validate each pathologist using the system and run the system in parallel with routine glass slide interpretation. Six pathologists ...

  7. Development of a 3D ultrasound system to investigate post-hemorrhagic hydrocephalus in pre-term neonates

    Science.gov (United States)

    Kishimoto, J.; Lee, D.; St. Lawrence, K.; Romano, W.; Fenster, A.; de Ribaupierre, S.

    2013-03-01

    Clinical intracranial ultrasound (US) is performed as a standard of care on neonates at risk of intraventricular hemorrhaging (IVH) and is also used after a diagnosis to monitor for potential ventricular dilation. However, it is difficult to estimate the volume of ventricles with 2D US due to their irregular shape. We developed a 3D US system to be used as an adjunct to a clinical system to investigate volumetric changes in the ventricles of neonates with IVH. Our system has been found have an error of within 1% of actual distance measurements in all three directions and volume measurements of manually segmented volumes from phantoms were not statistically significantly different from the actual values (p>0.3). Interobserver volume measurements of the lateral ventricles in a patient with grade III IVH found no significant differences between measurements. There is the potential to use this system in IVH patients to monitor the progression of ventriculomegaly over time.

  8. Fully integrated optical coherence tomography, ultrasound, and indocyanine green-based fluorescence tri-modality system for intravascular imaging.

    Science.gov (United States)

    Li, Yan; Jing, Joseph; Qu, Yueqiao; Miao, Yusi; Zhang, Buyun; Ma, Teng; Yu, Mingyue; Zhou, Qifa; Chen, Zhongping

    2017-02-01

    We present a tri-modality imaging system and fully integrated tri-modality probe for intravascular imaging. The tri-modality imaging system is able to simultaneously acquire optical coherence tomography (OCT), ultrasound (US), and fluorescence imaging. Moreover, for fluorescence imaging, we used the FDA-approved indocyanine green (ICG) dye as the contrast agent to target lipid-loaded macrophages. We conducted imaging from a male New Zealand white rabbit to evaluate the performance of the tri-modality system. In addition, tri-modality images of rabbit aortas were correlated with hematoxylin and eosin (H&E) histology to check the measurement accuracy. The fully integrated miniature tri-modality probe, together with the use of ICG dye suggest that the system is of great potential for providing a more accurate assessment of vulnerable plaques in clinical applications.

  9. Getting satisfaction: drivers of surgical Hospital Consumer Assessment of Health care Providers and Systems survey scores.

    Science.gov (United States)

    Iannuzzi, James C; Kahn, Steven A; Zhang, Linlin; Gestring, Mark L; Noyes, Katia; Monson, John R T

    2015-07-01

    Hospital consumer assessment of health care providers and systems (HCAHPS) survey scores formally recognize that patients are central to health care, shifting quality metrics from the physician to patient perspective. This study describes clinical predictors of patient satisfaction in surgical patients. Analysis of a single institution's Surgical Department HCAHPS responses was performed from March 2011-October 2012. The end points were top box satisfaction on two global domains. Multivariable regression was used to determine satisfaction predictors including HCAHPS domains, demographics, and clinical variables such as comorbidities, intensive care unit stay, emergency case, discharge day, floor transfers, complications, and ancillary procedures. In total, 978 surveys were evaluated representing admissions to Acute care and/or Trauma (n = 177, 18.1%), Thoracic (n = 169, 17.3%), Colorectal (n = 107, 10.9%), Transplant (n = 95, 9.7%), Vascular (n = 92, 9.4%), Oncology (n = 88, 9.0%), Plastic (n = 49, 5.0%), and Cardiac (n = 201, 20.6%) divisions. Overall, 658 patients (67.3%) had high satisfaction and 733 (74.9%) gave definite hospital recommendations. Hospital satisfaction was positively associated with an intensive care unit admission (odds ratio [OR] = 1.64, confidence interval [CI]: 1.20-2.23, P = 0.002) and satisfaction with provider and pain domains. Factors associated with decreased satisfaction were race (non-black minority compared with whites; OR = 0.41, CI: 0.21-0.83, P = 0.012), self-reported poor health (OR = 0.43, CI: 0.27-0.68, P nurse-patient interactions. These results help inform future quality improvement and resource allocation. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. An anesthesia information system for monitoring and record keeping during surgical anesthesia.

    Science.gov (United States)

    Klocke, H; Trispel, S; Rau, G; Hatzky, U; Daub, D

    1986-10-01

    We have developed an anesthesia information system (AIS) that supports the anesthesiologist in monitoring and recording during a surgical operation. In development of the system, emphasis was placed on providing an anesthesiologist-computer interface that can be adapted to typical situations during anesthesia and to individual user behavior. One main feature of this interface is the integration of the input and output of information. The only device for interaction between the anesthesiologist and the AIS is a touch-sensitive, high-resolution color display screen. The anesthesiologist enters information by touching virtual function keys displayed on the screen. A data window displays all data generated over time, such as automatically recorded vital signs, including blood pressure, heart rate, and rectal and esophageal temperatures, and manually entered variables, such as administered drugs, and ventilator settings. The information gathered by the AIS is presented on the cathode ray tube in several pages. A main distributor page gives an overall view of the content of every work page. A one-page record of the anesthesia is automatically plotted on a multicolor digital plotter during the operation. An example of the use of the AIS is presented from a field test of the system during which it was evaluated in the operating room without interfering with the ongoing operation. Medical staff who used the AIS imitated the anesthesiologist's recording and information search behavior but did not have responsibility for the conduct of the anesthetic.

  11. Surgical treatment of refractory epilepsy, secondary to central nervous system infection

    Institute of Scientific and Technical Information of China (English)

    Yunpeng Wang; Guojun Zhang; Lixin Cai; Yongjie Li

    2011-01-01

    Previous studies have focused on medial temporal lobe epilepsy secondary to central nervous system infections.Several large-sample analyses of multi-lobe injuries or complications of medial temporal lobe epilepsy have been reported.The present study selected 29 patients (10 males and 19 females with a mean age of 18 years) with refractory epilepsy secondary to central nervous system infections (meningitis in 8, encephalitis in 21)from Beijing Functional Neurosurgical Institute from May 2006 to August 2008.All patients underwent computer tomography or magnetic resonance imaging, as well as electroencephalogram examinations; cortical electrodes were embedded in 11 patients.In addition, 13 (45%) patients underwent anterior temporal lobectomy,and 16 (56%) underwent extratemporal corcticectomy.Results showed that 18 (62%) patients obtained favorable outcomes following surgical treatment, including 80% with temporal lobe epilepsy and 50% with extratemporal epilepsy.Central nervous system infection was not a contraindication for epilepsy treatment, and identification of epileptic foci proved to be crucial.In addition, a young age at infection, as well as prolonged latent period from time of infection to initial afebrile seizure, were 2 predictive factors for all patients.Cortical electrodes significantly increased the detection rate of epileptic foci, but did not improve prognosis of foci excision.

  12. Surgical Assisting

    Science.gov (United States)

    ... Insert and remove Foley urinary bladder catheter Place pneumatic tourniquet Confirm procedure with surgeon Drape patient within ... Technology and Surgical Assisting (NBSTSA) offers the CertifiedSurgical First Assistant (CSFA) credential, and the National Surgical Assistant ...

  13. A new motorized MR-guided ultrasound system for the delivery of large molecules to the rodent brain

    Science.gov (United States)

    Magnin, R.; Mériaux, S.; Le Bihan, D.; Dumont, E.; Larrat, B.

    2017-03-01

    Focused ultrasound combined with microbubbles injection has shown its potential to transiently disrupt the Blood Brain Barrier (BBB), allowing the delivery of large molecules to the Central Nervous System (CNS). However, the phenomenon has still to be investigated as the optimal parameters remain unknown up to date. To do so, we developed a new MR-guided motorized system, allowing the displacement of the transducer within preclinical magnets in order to choose the location of the opening. We demonstrated the capabilities of our system by opening the BBB along arbitrary trajectories. We also show the existence of an acoustic pressure threshold for BBB disruption estimated at about 0.3 MPa at 1.5 MHz by testing different acoustic conditions on the same animal. Finally, we investigated the BBB opening efficiency with the duty cycle. We proved that the disruption was greater with higher duty cycle.

  14. Scoring Systems for Outcome Prediction in a Cardiac Surgical Intensive Care Unit: A Comparative Study.

    Science.gov (United States)

    Exarchopoulos, Themistocles; Charitidou, Efstratia; Dedeilias, Panagiotis; Charitos, Christos; Routsi, Christina

    2015-07-01

    Most scoring systems used to predict clinical outcome in critical care were not designed for application in cardiac surgery patients. To compare the predictive ability of the most widely used scoring systems (Acute Physiology and Chronic Health Evaluation [APACHE] II, Simplified Acute Physiology Score [SAPS] II, and Sequential Organ Failure Assessment [SOFA]) and of 2 specialized systems (European System for Cardiac Operative Risk Evaluation [EuroSCORE] II and the cardiac surgery score [CASUS]) for clinical outcome in patients after cardiac surgery. Consecutive patients admitted to a cardiac surgical intensive care unit (CSICU) were prospectively studied. Data on the preoperative condition, intraoperative parameters, and postoperative course were collected. EuroSCORE II, CASUS, and scores from 3 general severity-scoring systems (APACHE II, SAPS II, and SOFA) were calculated on the first postoperative day. Clinical outcome was defined as 30-day mortality and in-hospital morbidity. A total of 150 patients were included. Thirty-day mortality was 6%. CASUS was superior in outcome prediction, both in relation to discrimination (area under curve, 0.89) and calibration (Brier score = 0.043, χ(2) = 2.2, P = .89), followed by EuroSCORE II for 30-day mortality (area under curve, 0.87) and SOFA for morbidity (Spearman ρ= 0.37 and 0.35 for the CSICU length of stay and duration of mechanical ventilation, respectively; Wilcoxon W = 367.5, P = .03 for probability of readmission to CSICU). CASUS can be recommended as the most reliable and beneficial option for benchmarking and risk stratification in cardiac surgery patients. ©2015 American Association of Critical-Care Nurses.

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries in planes that ... a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... areas of the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. For ... appearance, size or contour of organs, tissues, and vessels or to detect abnormal masses, such as tumors. ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the prostate is enlarged, also known as benign prostatic hyperplasia (BPH) , with measurements acquired as needed for any ... size with caption Related Articles and Media Benign Prostatic Hyperplasia (BPH) Prostate Cancer Ultrasound- and MRI-Guided Prostate ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls of the uterus). Sonohysterography allows for a more ... needle insertion) is usually minimal because the rectal wall is relatively insensitive to the pain in the ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ... of the pelvis may be obtained as an alternative imaging test, because it may be obtained with ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. ... an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  3. Ultrasound -- Pelvis

    Science.gov (United States)

    ... help diagnose symptoms experienced by women such as: pelvic pain abnormal bleeding other menstrual problems and help identify: ... children, pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic organs early ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the returning echoes from the tissues in the body. The principles are similar to sonar used by boats and submarines. The ultrasound image is immediately visible on a video display screen ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the returning echoes from the tissues in the body. The principles are similar to sonar used by boats and submarines. The ultrasound image is immediately visible on a video display screen ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ... barium exams, CT scanning , and MRI are the methods of choice in such a setting. Large patients ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... patient consultation. View full size with caption Related Articles and Media Benign Prostatic Hyperplasia (BPH) (Enlargement of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view ... detect: uterine anomalies uterine scars endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... use of a small transducer (probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the probe through the gel into the body. The transducer collects the sounds ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... use of a small transducer (probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the probe through the gel into the body. The transducer collects the sounds ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view ... detect: uterine anomalies uterine scars endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... uses sound waves to produce pictures of a man’s prostate gland and to help diagnose symptoms such ... also called transrectal ultrasound, provides images of a man's prostate gland and surrounding tissue. The exam typically ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... legs, neck and/or brain (in infants and children) or within various body organs such as the ... tumors other disorders of the urinary bladder In children, pelvic ultrasound can help evaluate: pelvic masses pelvic ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ... well on x-ray images. Ultrasound causes no health problems and may be repeated as often as ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exams are also used to monitor the health and development of an embryo or fetus during ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... physician during a routine physical exam or prostate cancer screening exam. an elevated blood test result. difficulty ... vessels or to detect abnormal masses, such as tumors. In an ultrasound examination, a transducer both sends ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page How is the procedure performed? In men, the prostate gland is located directly in front ... What are the limitations of Prostate Ultrasound Imaging? Men who have had the tail end of their ...

  1. Prostate Ultrasound

    Science.gov (United States)

    ... prostate. help diagnose the cause of a man's infertility. A transrectal ultrasound of the prostate gland is ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... prostate. help diagnose the cause of a man's infertility. A transrectal ultrasound of the prostate gland is ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... areas of the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. For ... make secure contact with the body and eliminate air pockets between the transducer and the skin that ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the object is as well as the object's size, shape and consistency (whether the object is solid ... ultrasound is used to detect changes in appearance, size or contour of organs, tissues, and vessels or ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... an ultrasound transducer – a plastic cylinder about the size of a finger – is inserted short distance into ... the object is as well as the object's size, shape and consistency (whether the object is solid ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... are reviewed. top of page What will I experience during and after the procedure? For a transabdominal ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ... barium exams, CT scanning , and MRI are the methods of choice in such a setting. Large patients ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exams are also used to monitor the health and development of an embryo or fetus during ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... difficulty urinating or an elevated blood test result. It’s also used to investigate a nodule found during ... difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide procedures such ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the examination process. To ensure a smooth experience, it often helps to explain the procedure to the ... on the amplitude (loudness), frequency (pitch) and time it takes for the ultrasound signal to return from ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to distract the child and make the time pass quickly. The ultrasound exam room may have a ... tissue attenuate (weaken) the sound waves as they pass deeper into the body. top of page Additional ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... examinations do not use ionizing radiation (as used in x-rays ), thus there is no radiation exposure to the patient. Because ultrasound images are captured in real-time, they can show the structure and ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries in planes that ... a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... are also used to monitor the health and development of an embryo or fetus during pregnancy. See ... I prepare? You should wear comfortable, loose-fitting clothing for your ultrasound exam. You may need to ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... also used to guide procedures such as needle biopsies , in which needles are used to extract a ... gynecologic examination. For a transrectal exam: If no biopsy is required, transrectal ultrasound of the prostate is ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exam room may have a television. Feel free to ask for your child's favorite channel. top ... be turned to either side to improve the quality of the images. After you are positioned on ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the ... small amount of gel is put on the skin to allow the sound waves to best travel ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the ... small amount of gel is put on the skin to allow the sound waves to best travel ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... extract a sample of cells from organs for laboratory testing. Doppler ultrasound images can help the physician ... the returning sound waves), as well as the type of body structure and composition of body tissue ...

  2. Hip Ultrasound

    Science.gov (United States)

    ... be used in infants to check for developmental dysplasia of the hip. Ultrasound is safe, noninvasive, and does not use ... be used to check the hips for developmental dysplasia of the hip (DDH), which in infants can range from a ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... called color Doppler ultrasonography, is a special ultrasound technique that allows the physician to see and evaluate ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... are obtained from different orientations to get the best views of the uterus and ovaries. Transvaginal ultrasound ... over time. Follow-up examinations are sometimes the best way to see if treatment is working or ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the ... the transducer (the device placed on the patient's skin to send and receive the returning sound waves), ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the ... the transducer (the device placed on the patient's skin to send and receive the returning sound waves), ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... or sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on the ... probe through the gel into the body. The transducer collects the sounds that bounce back and a ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Leave jewelry at home and wear loose, comfortable clothing. You may be asked to wear a gown. ... I prepare? You should wear comfortable, loose-fitting clothing for your ultrasound exam. You may need to ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Leave jewelry at home and wear loose, comfortable clothing. You may be asked to wear a gown ... I prepare? You should wear comfortable, loose-fitting clothing for your ultrasound exam. You may need to ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2017 Radiological ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2017 Radiological ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... physician during a routine physical exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  15. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... in the abdomen, arms, legs, neck and/or brain (in infants and children) or within various body organs ... or uterine cancers A transvaginal ultrasound is usually performed to view ...

  16. Prostate Ultrasound

    Medline Plus

    Full Text Available ... uses sound waves to produce pictures of a man’s prostate gland and to help diagnose symptoms such ... also called transrectal ultrasound, provides images of a man's prostate gland and surrounding tissue. The exam typically ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... a nodule found during a rectal exam, detect abnormalities, and determine whether the gland is enlarged. Ultrasound ... follow-up exam is done because a potential abnormality needs further evaluation with additional views or a ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries in planes that ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that ... as clots) narrowing of vessels tumors and congenital vascular malformations reduced or absent blood flow to various ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... information you were looking for? Yes No Please type your comment or suggestion into the following text box: Comment: E-mail: ... Images related to Ultrasound - Prostate Sponsored by Please ...