  1. Varying ultrasound power level to distinguish surgical instruments and tissue.

    Science.gov (United States)

    Ren, Hongliang; Anuraj, Banani; Dupont, Pierre E

    2018-03-01

    We investigate a new framework of surgical instrument detection based on power-varying ultrasound images with simple and efficient pixel-wise intensity processing. Without using complicated feature extraction methods, we identified the instrument with an estimated optimal power level and by comparing pixel values of varying transducer power level images. The proposed framework exploits the physics of ultrasound imaging system by varying the transducer power level to effectively distinguish metallic surgical instruments from tissue. This power-varying image-guidance is motivated from our observations that ultrasound imaging at different power levels exhibit different contrast enhancement capabilities between tissue and instruments in ultrasound-guided robotic beating-heart surgery. Using lower transducer power levels (ranging from 40 to 75% of the rated lowest ultrasound power levels of the two tested ultrasound scanners) can effectively suppress the strong imaging artifacts from metallic instruments and thus, can be utilized together with the images from normal transducer power levels to enhance the separability between instrument and tissue, improving intraoperative instrument tracking accuracy from the acquired noisy ultrasound volumetric images. We performed experiments in phantoms and ex vivo hearts in water tank environments. The proposed multi-level power-varying ultrasound imaging approach can identify robotic instruments of high acoustic impedance from low-signal-to-noise-ratio ultrasound images by power adjustments.

  2. Elastography Using Multi-Stream GPU: An Application to Online Tracked Ultrasound Elastography, In-Vivo and the da Vinci Surgical System

    Science.gov (United States)

    Deshmukh, Nishikant P.; Kang, Hyun Jae; Billings, Seth D.; Taylor, Russell H.; Hager, Gregory D.; Boctor, Emad M.

    2014-01-01

    A system for real-time ultrasound (US) elastography will advance interventions for the diagnosis and treatment of cancer by advancing methods such as thermal monitoring of tissue ablation. A multi-stream graphics processing unit (GPU) based accelerated normalized cross-correlation (NCC) elastography, with a maximum frame rate of 78 frames per second, is presented in this paper. A study of NCC window size is undertaken to determine the effect on frame rate and the quality of output elastography images. This paper also presents a novel system for Online Tracked Ultrasound Elastography (O-TRuE), which extends prior work on an offline method. By tracking the US probe with an electromagnetic (EM) tracker, the system selects in-plane radio frequency (RF) data frames for generating high quality elastograms. A novel method for evaluating the quality of an elastography output stream is presented, suggesting that O-TRuE generates more stable elastograms than generated by untracked, free-hand palpation. Since EM tracking cannot be used in all systems, an integration of real-time elastography and the da Vinci Surgical System is presented and evaluated for elastography stream quality based on our metric. The da Vinci surgical robot is outfitted with a laparoscopic US probe, and palpation motions are autonomously generated by customized software. It is found that a stable output stream can be achieved, which is affected by both the frequency and amplitude of palpation. The GPU framework is validated using data from in-vivo pig liver ablation; the generated elastography images identify the ablated region, outlined more clearly than in the corresponding B-mode US images. PMID:25541954

  3. Elastography using multi-stream GPU: an application to online tracked ultrasound elastography, in-vivo and the da Vinci Surgical System.

    Directory of Open Access Journals (Sweden)

    Nishikant P Deshmukh

    Full Text Available A system for real-time ultrasound (US elastography will advance interventions for the diagnosis and treatment of cancer by advancing methods such as thermal monitoring of tissue ablation. A multi-stream graphics processing unit (GPU based accelerated normalized cross-correlation (NCC elastography, with a maximum frame rate of 78 frames per second, is presented in this paper. A study of NCC window size is undertaken to determine the effect on frame rate and the quality of output elastography images. This paper also presents a novel system for Online Tracked Ultrasound Elastography (O-TRuE, which extends prior work on an offline method. By tracking the US probe with an electromagnetic (EM tracker, the system selects in-plane radio frequency (RF data frames for generating high quality elastograms. A novel method for evaluating the quality of an elastography output stream is presented, suggesting that O-TRuE generates more stable elastograms than generated by untracked, free-hand palpation. Since EM tracking cannot be used in all systems, an integration of real-time elastography and the da Vinci Surgical System is presented and evaluated for elastography stream quality based on our metric. The da Vinci surgical robot is outfitted with a laparoscopic US probe, and palpation motions are autonomously generated by customized software. It is found that a stable output stream can be achieved, which is affected by both the frequency and amplitude of palpation. The GPU framework is validated using data from in-vivo pig liver ablation; the generated elastography images identify the ablated region, outlined more clearly than in the corresponding B-mode US images.

  4. Elastography using multi-stream GPU: an application to online tracked ultrasound elastography, in-vivo and the da Vinci Surgical System.

    Science.gov (United States)

    Deshmukh, Nishikant P; Kang, Hyun Jae; Billings, Seth D; Taylor, Russell H; Hager, Gregory D; Boctor, Emad M

    2014-01-01

    A system for real-time ultrasound (US) elastography will advance interventions for the diagnosis and treatment of cancer by advancing methods such as thermal monitoring of tissue ablation. A multi-stream graphics processing unit (GPU) based accelerated normalized cross-correlation (NCC) elastography, with a maximum frame rate of 78 frames per second, is presented in this paper. A study of NCC window size is undertaken to determine the effect on frame rate and the quality of output elastography images. This paper also presents a novel system for Online Tracked Ultrasound Elastography (O-TRuE), which extends prior work on an offline method. By tracking the US probe with an electromagnetic (EM) tracker, the system selects in-plane radio frequency (RF) data frames for generating high quality elastograms. A novel method for evaluating the quality of an elastography output stream is presented, suggesting that O-TRuE generates more stable elastograms than generated by untracked, free-hand palpation. Since EM tracking cannot be used in all systems, an integration of real-time elastography and the da Vinci Surgical System is presented and evaluated for elastography stream quality based on our metric. The da Vinci surgical robot is outfitted with a laparoscopic US probe, and palpation motions are autonomously generated by customized software. It is found that a stable output stream can be achieved, which is affected by both the frequency and amplitude of palpation. The GPU framework is validated using data from in-vivo pig liver ablation; the generated elastography images identify the ablated region, outlined more clearly than in the corresponding B-mode US images.

  5. Surgical vs ultrasound-guided drainage of deep neck space abscesses: a randomized controlled trial: surgical vs ultrasound drainage.

    Science.gov (United States)

    Biron, Vincent L; Kurien, George; Dziegielewski, Peter; Barber, Brittany; Seikaly, Hadi

    2013-02-26

    Deep neck space abscesses (DNAs) are relatively common otolaryngology-head and neck surgery emergencies and can result in significant morbidity with potential mortality. Traditionally, surgical incision and drainage (I&D) with antibiotics has been the mainstay of treatment. Some reports have suggested that ultrasound-guided drainage (USD) is a less invasive and effective alternative in select cases. To compare I&D vs USD of well-defined DNAs, using a randomized controlled clinical trial design. The primary outcome measure was effectiveness (length of hospital stay (LOHS) and safety), and the secondary outcome measure was overall cost to the healthcare system. Patients presenting to the University of Alberta Emergency Department with a well-defined deep neck space abscess were recruited in the study. Patients were randomized to surgical or US-guided drainage, placed on intravenous antibiotics and admitted with airway precautions. Following drainage with either intervention, abscess collections were cultured and drains were left in place until discharge. Seventeen patients were recruited in the study. We found a significant difference in mean LOHS between patients who underwent USD (3.1 days) vs I&D (5.2 days). We identified significant cost savings associated with USD with a 41% cost reduction in comparison to I&D. USD drainage of deep neck space abscesses in a certain patient population is effective, safe, and results in a significant cost savings to the healthcare system.

  6. A Diagnostic Ultrasound Imaging System

    International Nuclear Information System (INIS)

    Lee, Seong Woo

    1999-01-01

    The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result, their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result, the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described

  7. Automatic localization of the da Vinci surgical instrument tips in 3-D transrectal ultrasound.

    Science.gov (United States)

    Mohareri, Omid; Ramezani, Mahdi; Adebar, Troy K; Abolmaesumi, Purang; Salcudean, Septimiu E

    2013-09-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) using the da Vinci surgical system is the current state-of-the-art treatment option for clinically confined prostate cancer. Given the limited field of view of the surgical site in RALRP, several groups have proposed the integration of transrectal ultrasound (TRUS) imaging in the surgical workflow to assist with accurate resection of the prostate and the sparing of the neurovascular bundles (NVBs). We previously introduced a robotic TRUS manipulator and a method for automatically tracking da Vinci surgical instruments with the TRUS imaging plane, in order to facilitate the integration of intraoperative TRUS in RALRP. Rapid and automatic registration of the kinematic frames of the da Vinci surgical system and the robotic TRUS probe manipulator is a critical component of the instrument tracking system. In this paper, we propose a fully automatic registration technique based on automatic 3-D TRUS localization of robot instrument tips pressed against the air-tissue boundary anterior to the prostate. The detection approach uses a multiscale filtering technique to identify and localize surgical instrument tips in the TRUS volume, and could also be used to detect other surface fiducials in 3-D ultrasound. Experiments have been performed using a tissue phantom and two ex vivo tissue samples to show the feasibility of the proposed methods. Also, an initial in vivo evaluation of the system has been carried out on a live anaesthetized dog with a da Vinci Si surgical system and a target registration error (defined as the root mean square distance of corresponding points after registration) of 2.68 mm has been achieved. Results show this method's accuracy and consistency for automatic registration of TRUS images to the da Vinci surgical system.

  8. [da Vinci surgical system].

    Science.gov (United States)

    Watanabe, Gou; Ishikawa, Norihiro

    2014-07-01

    The da Vinci surgical system was developed by Intuitive Surgical Inc. in the United States as an endoscopic surgical device to assist remote control surgeries. In 1998, the Da Vinci system was first used for cardiothoracic procedures. Currently a combination of robot-assisted internal thoracic artery harvest together with coronary artery bypass grafting (CABG) through a mini-incision (ThoraCAB) or totally endoscopic procedures including anastomoses under robotic assistance (TECAB) are being conducted for the treatment of coronary artery diseases. With the recent advances in catheter interventions, hybrid procedures combining catheter intervention with ThoraCAB or TECAB are anticipated in the future.On the other hand, with the decrease in number of coronary artery bypass surgeries, the share of valvular surgeries is expected to increase in the future. Among them, mitral valvuloplasty for mitral regurgitation is anticipated to be conducted mainly by low-invasive procedures, represented by minimally invasive cardiac surgery( MICS) and robot-assisted surgery. Apart from the intrinsic good surgical view, robotic-assisted systems offer additional advantages of the availability of an amplified view and the easy to observe the mitral valve in the physiological position. Thus, robotic surgical surgeries that make complicated procedures easier are expected to accomplish further developments in the future. Furthermore, while the number of surgeries for atrial septal defects has decreased dramatically following the widespread use of Amplatzer septal occluder, robotic surgery may become a good indication for cases in which the Amplatzer device is not indicated. In Japan, clinical trial of the da Vinci robotic system for heart surgeries has been completed. Statutory approval of the da Vinci system for mitral regurgitation and atrial septal defects is anticipated in the next few years.

  9. Surgical fiducial segmentation and tracking for pose estimation based on ultrasound B-mode images.

    Science.gov (United States)

    Lei Chen; Kuo, Nathanael; Aalamifar, Fereshteh; Narrow, David; Coon, Devin; Prince, Jerry; Boctor, Emad M

    2016-08-01

    Doppler ultrasound is a non-invasive diagnostic tool for the quantitative measurement of blood flow. However, given that it provides velocity data that is dependent on the location and angle of measurement, repeat measurements to detect problems over time may require an expert to return to the same location. We therefore developed an image-guidance system based on ultrasound B-mode images that enables an inexperienced user to position the ultrasound probe at the same site repeatedly in order to acquire a comparable time series of Doppler readings. The system utilizes a bioresorbable fiducial and complementing software composed of the fiducial detection, key points tracking, probe pose estimation, and graphical user interface (GUI) modules. The fiducial is an echogenic marker that is implanted at the surgical site and can be detected and tracked during ultrasound B-mode screening. The key points on the marker can next be used to determine the pose of the ultrasound probe with respect to the marker. The 3D representation of the probe with its position and orientation are then displayed in the GUI for the user guidance. The fiducial detection has been tested on the data sets collected from three animal studies. The pose estimation algorithm was validated by five data sets collected by a UR5 robot. We tested the system on a plastisol phantom and showed that it can detect and track the fiducial marker while displaying the probe pose in real-time.

  10. [Ultrasound of the urinary system].

    Science.gov (United States)

    Segura-Grau, A; Herzog, R; Díaz-Rodriguez, N; Segura-Cabral, J M

    2016-09-01

    Ultrasound techniques are able to provide a fairly complete examination of the urinary system, achieving a high sensitivity in relevant-pathology detection, especially in the kidney, bladder and prostate. Early detection of pathologies such as tumors or urinary tract obstructions, sometimes even before their clinical manifestation, has improved their management and prognosis in many cases. This, added to its low cost and harmlessness, makes ultrasound ideal for early approaches and follow-up of a wide number of urinary system pathologies. In this article, the ultrasound characteristics of the main urinary system pathologies that can be diagnosed by this technique, are reviewed. Copyright © 2014 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.

  11. OSPACS: Ultrasound image management system

    Directory of Open Access Journals (Sweden)

    Bessant Conrad

    2008-06-01

    Full Text Available Abstract Background Ultrasound scanning uses the medical imaging format, DICOM, for electronically storing the images and data associated with a particular scan. Large health care facilities typically use a picture archiving and communication system (PACS for storing and retrieving such images. However, these systems are usually not suitable for managing large collections of anonymized ultrasound images gathered during a clinical screening trial. Results We have developed a system enabling the accurate archiving and management of ultrasound images gathered during a clinical screening trial. It is based upon a Windows application utilizing an open-source DICOM image viewer and a relational database. The system automates the bulk import of DICOM files from removable media by cross-validating the patient information against an external database, anonymizing the data as well as the image, and then storing the contents of the file as a field in a database record. These image records may then be retrieved from the database and presented in a tree-view control so that the user can select particular images for display in a DICOM viewer or export them to external media. Conclusion This system provides error-free automation of ultrasound image archiving and management, suitable for use in a clinical trial. An open-source project has been established to promote continued development of the system.

  12. Ultrasound findings in biliary system

    International Nuclear Information System (INIS)

    Park, Won Sik; Lee, Yong Woo; Cheung, Hwan

    1986-01-01

    In the liver and biliary system ultrasound has emerged as one of the most useful imaging techniques. It is usually the first radiological procedure selected and is often sufficient alone to enable a clinical decision to be made. Good result with ultrasound depend critically on expert scanning technique coupled with an understanding of tomographic anatomy and, of course, an appreciation of the clinical significance of any findings. In addition to we'd like to stress on the ultrasonical anatomy and for the technologist and also discuss about pathological part

  13. Active ultrasound pattern injection system (AUSPIS for interventional tool guidance.

    Directory of Open Access Journals (Sweden)

    Xiaoyu Guo

    Full Text Available Accurate tool tracking is a crucial task that directly affects the safety and effectiveness of many interventional medical procedures. Compared to CT and MRI, ultrasound-based tool tracking has many advantages, including low cost, safety, mobility and ease of use. However, surgical tools are poorly visualized in conventional ultrasound images, thus preventing effective tool tracking and guidance. Existing tracking methods have not yet provided a solution that effectively solves the tool visualization and mid-plane localization accuracy problem and fully meets the clinical requirements. In this paper, we present an active ultrasound tracking and guiding system for interventional tools. The main principle of this system is to establish a bi-directional ultrasound communication between the interventional tool and US imaging machine within the tissue. This method enables the interventional tool to generate an active ultrasound field over the original imaging ultrasound signals. By controlling the timing and amplitude of the active ultrasound field, a virtual pattern can be directly injected into the US machine B mode display. In this work, we introduce the time and frequency modulation, mid-plane detection, and arbitrary pattern injection methods. The implementation of these methods further improves the target visualization and guiding accuracy, and expands the system application beyond simple tool tracking. We performed ex vitro and in vivo experiments, showing significant improvements of tool visualization and accurate localization using different US imaging platforms. An ultrasound image mid-plane detection accuracy of ±0.3 mm and a detectable tissue depth over 8.5 cm was achieved in the experiment. The system performance is tested under different configurations and system parameters. We also report the first experiment of arbitrary pattern injection to the B mode image and its application in accurate tool tracking.

  14. Imaging in gynecological disease. 10: Clinical and ultrasound characteristics of decidualized endometriomas surgically removed during pregnancy.

    Science.gov (United States)

    Mascilini, F; Moruzzi, C; Giansiracusa, C; Guastafierro, F; Savelli, L; De Meis, L; Epstein, E; Timor-Tritsch, I E; Mailath-Pokorny, M; Ercoli, A; Exacoustos, C; Benacerraf, B R; Valentin, L; Testa, A C

    2014-09-01

    To describe the clinical history and ultrasound findings in women with decidualized endometriomas surgically removed during pregnancy. In this retrospective study, women with a histological diagnosis of decidualized endometrioma during pregnancy who had undergone preoperative ultrasound examination were identified from the databases of seven ultrasound centers. The ultrasound appearance of the tumors was described on the basis of ultrasound images, ultrasound reports and research protocols (when applicable) by one author from each center using the terms and definitions of the International Ovarian Tumor Analysis (IOTA) group. In addition, two authors reviewed together available digital ultrasound images and used pattern recognition to describe the typical ultrasound appearance of decidualized endometriomas. Eighteen eligible women were identified. Median age was 34 (range, 20-43) years. Median gestational age at surgical removal of the decidualized endometrioma was 18 (range, 11-41) weeks. Seventeen women (94%) were asymptomatic and one presented with pelvic pain. In three of the 18 women an ultrasound diagnosis of endometrioma had been made before pregnancy. The original ultrasound examiner was uncertain whether the mass was benign or malignant in 10 (56%) women and suggested a diagnosis of benignity in nine (50%) women, borderline in eight women (44%), and invasive malignancy in one (6%) woman. Seventeen decidualized endometriomas contained a papillary projection, and in 16 of these at least one of the papillary projections was vascularized at power or color Doppler examination. The number of cyst locules varied between one (n = 11) and four. No woman had ascites. When using pattern recognition, most decidualized endometriomas (14/17, 82%) were described as manifesting vascularized rounded papillary projections with a smooth contour in an ovarian cyst with one or a few cyst locules and ground-glass or low-level echogenicity of the cyst fluid. Rounded vascularized

  15. Towards Safe Robotic Surgical Systems

    DEFF Research Database (Denmark)

    Sloth, Christoffer; Wisniewski, Rafael

    2015-01-01

    a controller for motion compensation in beating-heart surgery, and prove that it is safe, i.e., the surgical tool is kept within an allowable distance and orientation of the heart. We solve the problem by simultaneously finding a control law and a barrier function. The motion compensation system is simulated...... from several initial conditions to demonstrate that the designed control system is safe for every admissible initial condition....

  16. [A new technique for ensuring negative surgical margins during partial nephrectomy: the ex vivo ultrasound control].

    Science.gov (United States)

    Desmonts, A; Tillou, X; Le Gal, S; Secco, M; Orczyk, C; Bensadoun, H; Doerfler, A

    2013-10-01

    To evaluate the feasibility and the efficiency of intraoperative ex vivo ultrasound of resection margins in patients undergoing partial nephrectomy by urologist. Patients undergoing partial nephrectomy from July 2010 to November 2012 for T1-T2 renal tumors were included in analysis. Tumor margin status was immediately determined by ex vivo ultrasound done by the surgeon himself. Results were compared with margin status on definitive pathological evaluation. A total of 26 men and 15 women with a median age of 61 (30-82) years old were included in analysis. Intraoperative ex vivo ultrasound revealed negative surgical margins in 38 cases and positive margins in two. Final pathological results revealed negative margins in all except one case. Ultrasound sensitivity and specificity were 100% and 97%, respectively. Mean ultrasound duration was 1minute±1. Mean tumor and margin sizes were 3.4±1.8cm and 2.38±1.76mm, respectively. Intraoperative ex vivo ultrasound of resection margins in patients undergoing partial nephrectomy by a urologist seemed to be feasible, efficient and easy. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  17. Ultrasound and MRI predictors of surgical bowel resection in pediatric Crohn disease

    International Nuclear Information System (INIS)

    Rosenbaum, Daniel G.; Conrad, Maire A.; Kelsen, Judith R.; Biko, David M.; Anupindi, Sudha A.; Ruchelli, Eduardo D.

    2017-01-01

    Imaging predictors for surgery in children with Crohn disease are lacking. To identify imaging features of the terminal ileum on short-interval bowel ultrasound (US) and MR enterography (MRE) in children with Crohn disease requiring surgical bowel resection and those managed by medical therapy alone. This retrospective study evaluated patients 18 years and younger with Crohn disease undergoing short-interval bowel US and MRE (within 2 months of one another), as well as subsequent ileocecectomy or endoscopy within 3 months of imaging. Appearance of the terminal ileum on both modalities was compared between surgical patients and those managed with medical therapy, with the following parameters assessed: bowel wall thickness, mural stratification, vascularity, fibrofatty proliferation, abscess, fistula and stricture on bowel US; bowel wall thickness, T2 ratio, enhancement pattern, mesenteric edema, fibrofatty proliferation, abscess, fistula and stricture on MRE. A two-sided t-test was used to compare means, a Mann-Whitney U analysis was used for non-parametric parameter scores, and a chi-square or two-sided Fisher exact test compared categorical variables. Imaging findings in surgical patients were correlated with location-matched histopathological scores of inflammation and fibrosis using a scoring system adapted from the Simple Endoscopic Score for Crohn Disease, and a Spearman rank correlation coefficient was used to compare inflammation and fibrosis on histopathology. Twenty-two surgical patients (mean age: 16.5 years; male/female: 13/9) and 20 nonsurgical patients (mean age: 14.8; M/F: 8/12) were included in the final analysis. On US, the surgical group demonstrated significantly increased mean bowel wall thickness (6.1 mm vs. 4.7 mm for the nonsurgical group; P = 0.01), loss of mural stratification (odds ratio [OR] = 6.3; 95% confidence interval [CI]: 1.4-28.4; P = 0.02) and increased fibrofatty proliferation (P = 0.04). On MRE, the surgical group showed

  18. Ultrasound and MRI predictors of surgical bowel resection in pediatric Crohn disease

    Energy Technology Data Exchange (ETDEWEB)

    Rosenbaum, Daniel G. [NewYork-Presbyterian Hospital/Weill Cornell Medicine, Division of Pediatric Radiology, New York, NY (United States); Conrad, Maire A.; Kelsen, Judith R. [The Children' s Hospital of Philadelphia, Division of Gastroenterology, Hepatology and Nutrition, Philadelphia, PA (United States); Biko, David M.; Anupindi, Sudha A. [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Ruchelli, Eduardo D. [The Children' s Hospital of Philadelphia, Division of Anatomic Pathology, Philadelphia, PA (United States)

    2017-01-15

    Imaging predictors for surgery in children with Crohn disease are lacking. To identify imaging features of the terminal ileum on short-interval bowel ultrasound (US) and MR enterography (MRE) in children with Crohn disease requiring surgical bowel resection and those managed by medical therapy alone. This retrospective study evaluated patients 18 years and younger with Crohn disease undergoing short-interval bowel US and MRE (within 2 months of one another), as well as subsequent ileocecectomy or endoscopy within 3 months of imaging. Appearance of the terminal ileum on both modalities was compared between surgical patients and those managed with medical therapy, with the following parameters assessed: bowel wall thickness, mural stratification, vascularity, fibrofatty proliferation, abscess, fistula and stricture on bowel US; bowel wall thickness, T2 ratio, enhancement pattern, mesenteric edema, fibrofatty proliferation, abscess, fistula and stricture on MRE. A two-sided t-test was used to compare means, a Mann-Whitney U analysis was used for non-parametric parameter scores, and a chi-square or two-sided Fisher exact test compared categorical variables. Imaging findings in surgical patients were correlated with location-matched histopathological scores of inflammation and fibrosis using a scoring system adapted from the Simple Endoscopic Score for Crohn Disease, and a Spearman rank correlation coefficient was used to compare inflammation and fibrosis on histopathology. Twenty-two surgical patients (mean age: 16.5 years; male/female: 13/9) and 20 nonsurgical patients (mean age: 14.8; M/F: 8/12) were included in the final analysis. On US, the surgical group demonstrated significantly increased mean bowel wall thickness (6.1 mm vs. 4.7 mm for the nonsurgical group; P = 0.01), loss of mural stratification (odds ratio [OR] = 6.3; 95% confidence interval [CI]: 1.4-28.4; P = 0.02) and increased fibrofatty proliferation (P = 0.04). On MRE, the surgical group showed

  19. Ultrasound and MRI predictors of surgical bowel resection in pediatric Crohn disease.

    Science.gov (United States)

    Rosenbaum, Daniel G; Conrad, Maire A; Biko, David M; Ruchelli, Eduardo D; Kelsen, Judith R; Anupindi, Sudha A

    2017-01-01

    Imaging predictors for surgery in children with Crohn disease are lacking. To identify imaging features of the terminal ileum on short-interval bowel ultrasound (US) and MR enterography (MRE) in children with Crohn disease requiring surgical bowel resection and those managed by medical therapy alone. This retrospective study evaluated patients 18 years and younger with Crohn disease undergoing short-interval bowel US and MRE (within 2 months of one another), as well as subsequent ileocecectomy or endoscopy within 3 months of imaging. Appearance of the terminal ileum on both modalities was compared between surgical patients and those managed with medical therapy, with the following parameters assessed: bowel wall thickness, mural stratification, vascularity, fibrofatty proliferation, abscess, fistula and stricture on bowel US; bowel wall thickness, T2 ratio, enhancement pattern, mesenteric edema, fibrofatty proliferation, abscess, fistula and stricture on MRE. A two-sided t-test was used to compare means, a Mann-Whitney U analysis was used for non-parametric parameter scores, and a chi-square or two-sided Fisher exact test compared categorical variables. Imaging findings in surgical patients were correlated with location-matched histopathological scores of inflammation and fibrosis using a scoring system adapted from the Simple Endoscopic Score for Crohn Disease, and a Spearman rank correlation coefficient was used to compare inflammation and fibrosis on histopathology. Twenty-two surgical patients (mean age: 16.5 years; male/female: 13/9) and 20 nonsurgical patients (mean age: 14.8; M/F: 8/12) were included in the final analysis. On US, the surgical group demonstrated significantly increased mean bowel wall thickness (6.1 mm vs. 4.7 mm for the nonsurgical group; P = 0.01), loss of mural stratification (odds ratio [OR] = 6.3; 95% confidence interval [CI]: 1.4-28.4; P = 0.02) and increased fibrofatty proliferation (P = 0.04). On MRE, the

  20. High-frequency ultrasound in carpal tunnel syndrome: assessment of patient eligibility for surgical treatment

    Directory of Open Access Journals (Sweden)

    Katarzyna Kapuścińska

    2015-09-01

    Full Text Available Carpal tunnel syndrome (CTS is the most common entrapment neuropathy and a frequent cause of sick leaves because of work-related hand overload. That is why an early diagnosis and adequate treatment (conservative or surgical are essential for optimal patient management. Aim: The aim of the study is to assess the usefulness of high-frequency ultrasound in CTS for the assessment of patient eligibility for surgical treatment. Material and methods: The study involved 62 patients (50 women and 12 men, aged 28–70, mean age 55.2 with scheduled surgeries of CTS on the basis of clinical symptoms, physical examination performed by a neurosurgeon and a positive result of EMG testing. The ultrasound examinations of the wrist were performed in all these patients. On the basis of the collected data, the author has performed multiple analyses to confi rm the usefulness of ultrasound imaging in assessing patient eligibility for surgical treatment of CTS. Results: US examinations showed evidence of median nerve compression at the level of the carpal tunnel in all of the examined patients. This was further confi rmed during surgical procedures. The mean value of the cross-sectional area at the proximal part of the pisiform bone was 17.45 mm2 (min. 12 mm2 , max. 31 mm2 . Nerve hypoechogenicity proximal to the nerve compression site was visible in all 62 patients (100%. Increased nerve vascularity on the transverse section was present in 50 patients (80.65%. Conclusions: Ultrasonography with the use of high-frequency transducers is a valuable diagnostic tool both for assessing patient eligibility for surgical treatment of CTS, and in postoperative assessment of the treatment efficacy.

  1. Output control of da Vinci surgical system's surgical graspers.

    Science.gov (United States)

    Johnson, Paul J; Schmidt, David E; Duvvuri, Umamaheswar

    2014-01-01

    The number of robot-assisted surgeries performed with the da Vinci surgical system has increased significantly over the past decade. The articulating movements of the robotic surgical grasper are controlled by grip controls at the master console. The user interface has been implicated as one contributing factor in surgical grasping errors. The goal of our study was to characterize and evaluate the user interface of the da Vinci surgical system in controlling surgical graspers. An angular manipulator with force sensors was used to increment the grip control angle as grasper output angles were measured. Input force at the grip control was simultaneously measured throughout the range of motion. Pressure film was used to assess the maximum grasping force achievable with the endoscopic grasping tool. The da Vinci robot's grip control angular input has a nonproportional relationship with the grasper instrument output. The grip control mechanism presents an intrinsic resistant force to the surgeon's fingertips and provides no haptic feedback. The da Vinci Maryland graspers are capable of applying up to 5.1 MPa of local pressure. The angular and force input at the grip control of the da Vinci robot's surgical graspers is nonproportional to the grasper instrument's output. Understanding the true relationship of the grip control input to grasper instrument output may help surgeons understand how to better control the surgical graspers and promote fewer grasping errors. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Plunging ranulas: high-resolution ultrasound for diagnosis and surgical management

    International Nuclear Information System (INIS)

    Jain, Prabha; Jain, Ravi; Morton, Randall P.; Ahmad, Zahoor

    2010-01-01

    We see a high incidence of plunging ranulas, particularly in Maori and Polynesian populations. We have investigated the usefulness of ultrasound in the diagnosis and management of plunging ranulas and present our findings. Thirty-three new cases were examined over 4 years (June 2004 to October 2008). High-resolution ultrasound was very successful in determining the extent of the plunging ranula, confirming the cystic nature of the lesion, assessing the status of the mylohyoid muscle (a defect demonstrated in 100% of our cases) and evaluating the sublingual gland for rupture or herniation. Correlation with surgical findings was available for 30 cases. There was excellent ultrasonographic and surgical correlation, particularly with respect to submandibular space cystic collection (29 of 30 cases, 96.7%) and mylohyoid defects (27 of 30 cases, 90%). With the considerations of cost, accessibility and the fact that many of our patients are young (median of 20 years), ultrasound is recommended as the preferred examination for plunging ranula. (orig.)

  3. Plunging ranulas: high-resolution ultrasound for diagnosis and surgical management

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Prabha [Middlemore Hospital, Counties Manakau, Department of Radiology, P.O. Box 93311, Otahuhu, Auckland (New Zealand); Jain, Ravi [Waikato Hospital, Department of Plastic Surgery, Hamilton (New Zealand); Morton, Randall P.; Ahmad, Zahoor [Middlemore Hospital, Counties Manakau, Department of ENT Surgery, P.O. Box 93311, Otahuhu, Auckland (New Zealand)

    2010-06-15

    We see a high incidence of plunging ranulas, particularly in Maori and Polynesian populations. We have investigated the usefulness of ultrasound in the diagnosis and management of plunging ranulas and present our findings. Thirty-three new cases were examined over 4 years (June 2004 to October 2008). High-resolution ultrasound was very successful in determining the extent of the plunging ranula, confirming the cystic nature of the lesion, assessing the status of the mylohyoid muscle (a defect demonstrated in 100% of our cases) and evaluating the sublingual gland for rupture or herniation. Correlation with surgical findings was available for 30 cases. There was excellent ultrasonographic and surgical correlation, particularly with respect to submandibular space cystic collection (29 of 30 cases, 96.7%) and mylohyoid defects (27 of 30 cases, 90%). With the considerations of cost, accessibility and the fact that many of our patients are young (median of 20 years), ultrasound is recommended as the preferred examination for plunging ranula. (orig.)

  4. Ultrasound guided aspiration of breast abscess as an alternative to surgical incision and drainage

    International Nuclear Information System (INIS)

    Naper, M.A.; Shaikh, M.S.; Dholia, K.R.

    2017-01-01

    To evaluate the outcome and assess the success rate of ultrasound guided aspiration of breast abscess as an alternative to surgical incision and drainage. Methodology: A prospective descriptive study was carried out at Department of Surgery, Chandka Medical College Hospital, Larkana, Pakistan, from January 2015 to December 2015. A total of 111 patients of breast abscess who underwent ultrasound guided aspiration without anesthesias with oral antibiotic cover were studied. Females with breast abscess within seven days, and the abscess size was <3cm were included in the study. Males, antibioma and inflammatory carcinoma were excluded from the study. Outcome of success or failure was observed within two weeks and recorded. Results: Out of 111 patients, 68.46% were lactating and 31.53% were non-lactating women, with ages ranging from 18 to 60 years (mean 36.5 years). The successful rate with complete resolution after ultrasound guided aspiration was observed in 94.5%. 80.82% responded after single aspiration, 12.38% after two times aspiration, and 6.66% after multiple aspirations, while 5.4% of patients required incision and drainage. Conclusion: Ultrasound guided aspiration of breast abscess is an effective treatment option with a diameter of <3cm, which can be recommended as a routine outpatient procedure. (author)

  5. Modification of Food Systems by Ultrasound

    Directory of Open Access Journals (Sweden)

    L. M. Carrillo-Lopez

    2017-01-01

    Full Text Available This review describes the mechanism, operation, and recent potential applications of ultrasound in various food systems, as well as the physical and chemical effects of ultrasound treatments on the conservation and modification of different groups of food. Acoustic energy has been recognized as an emerging technology with great potential for applications in the food industry. The phenomenon of acoustic cavitation, which modifies the physical, chemical, and functional properties of food, can be used to improve existing processes and to develop new ones. The combination of ultrasonic energy with a sanitizing agent can improve the effect of microbial reduction in foods and, thereby, their quality. Finally, it is concluded that the use of ultrasound in food is a very promising area of research; however, more research is still needed before applying this technology in a wider range of industrial sectors.

  6. Ultrasound systems for blood velocity estimation

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    1998-01-01

    Medical ultrasound scanners can be used both for displayinggray-scale images of the anatomy and for visualizing theblood flow dynamically in the body.The systems can interrogate the flow at a single position in the bodyand there find the velocity distribution over time. They can also show adynamic...

  7. Need for intraoperative ultrasound and surgical recommendation for partial nephrectomy: correlation with tumor imaging features and urologist practice patterns.

    Science.gov (United States)

    Sun, Maryellen R M; Wagner, Andrew A; San Francisco, Ignacio F; Brook, Alexander; Kavoussi, Louis; Russo, Paul; Steele, Graeme; Viterbo, Rosalia; Pedrosa, Ivan

    2012-03-01

    This study aimed to evaluate the need for intraoperative ultrasound (IOUS) and recommendation for surgical approach in the resection of renal tumors through a survey of practicing urologists, with correlation to tumor imaging features and urologist practice pattern. An institutional review board-approved retrospective review, compliant with the Health Insurance Portability and Accountability Act, of 44 renal tumors that underwent laparoscopic partial nephrectomy at the study institution was performed. The numeric component of the RENAL nephrometry score (radius [diameter], % exophytic, nearness [to collecting system/renal sinus], location) was calculated for each case using preoperative computed tomography/magnetic resonance imaging. Five anonymized images of each tumor were presented to 4 academic urologists with varying practice patterns. Reviewers independently scored each case for its need for IOUS, for recommendation of a surgical technique, and for the difficulty of the proposed surgery. The RENAL scores were as follows: RENAL 1 (low complexity, score 4-6; n = 19); RENAL 2 (moderate complexity, score 7-9; n = 23); RENAL 3 (high complexity, score 10-12; n = 2). The only RENAL score component significantly influencing need for IOUS was percentage exophytic (P = 0.00002). There was an inverse relationship between normalized and averaged need for IOUS and percentage exophytic (P recommendation of surgical method was the reviewer him/herself, with each reviewer's recommendations closely matching his/her practice pattern. Size and percentage exophytic represented the only tumor features significantly (P = 0.03) influencing surgical recommendation. There was a significant difference in the perceived need for IOUS and surgical recommendation when 4 academic urologists reviewed a series of renal masses requiring resection. Percentage exophytic correlated inversely with need for IOUS. Urologist's practice pattern and tumor size and percentage exophytic were most

  8. Doppler ultrasound and magnetic resonance for evaluation of patients treated surgically for aortic coarctation

    International Nuclear Information System (INIS)

    Canteli, B.; Saez, F.; Garcia, F.; Cabrera, A.; Galdeano, J.M.; Rodriguez, O.

    1994-01-01

    Doppler ultrasound and magnetic resonance were performed in a series of 39 patients who had been treated surgically for aortic coarctation. The purpose was to assess the different Doppler gradients, comparing the findings with morphological data disclosed by magnetic resonance. The aortic caliber in the operative field was pathological in 7 patients (ratio between the caliber at the level of the lesion and that of descending aorta of less than 0.7). When the patients were considered as a group. Doppler ultrasound did not show satisfactory sensitivity (29%-43%), specificity (74%) or positive predictive value (17%-23%). Only the negative predictive value (85%-88%) presented more favorable results. When the Subgroup of patients without associated cardiac abnormalities or collateral circulation was studied alone, the following results were found: sensitivity, 100%; specificity, 81%-90%, positive predictive value, 33%-50%, negative predictive value, 100%, similar to those reported in the literature. Thus, we consider that Doppler ultrasound is a harmless and low cost diagnostic method that is highly suitable for follow-up of these patients, within certain limits. Magnetic resonance is the method of choice for the noninvasive assessment of aortic morphology. (Author)

  9. Actuator-Assisted Calibration of Freehand 3D Ultrasound System.

    Science.gov (United States)

    Koo, Terry K; Silvia, Nathaniel

    2018-01-01

    Freehand three-dimensional (3D) ultrasound has been used independently of other technologies to analyze complex geometries or registered with other imaging modalities to aid surgical and radiotherapy planning. A fundamental requirement for all freehand 3D ultrasound systems is probe calibration. The purpose of this study was to develop an actuator-assisted approach to facilitate freehand 3D ultrasound calibration using point-based phantoms. We modified the mathematical formulation of the calibration problem to eliminate the need of imaging the point targets at different viewing angles and developed an actuator-assisted approach/setup to facilitate quick and consistent collection of point targets spanning the entire image field of view. The actuator-assisted approach was applied to a commonly used cross wire phantom as well as two custom-made point-based phantoms (original and modified), each containing 7 collinear point targets, and compared the results with the traditional freehand cross wire phantom calibration in terms of calibration reproducibility, point reconstruction precision, point reconstruction accuracy, distance reconstruction accuracy, and data acquisition time. Results demonstrated that the actuator-assisted single cross wire phantom calibration significantly improved the calibration reproducibility and offered similar point reconstruction precision, point reconstruction accuracy, distance reconstruction accuracy, and data acquisition time with respect to the freehand cross wire phantom calibration. On the other hand, the actuator-assisted modified "collinear point target" phantom calibration offered similar precision and accuracy when compared to the freehand cross wire phantom calibration, but it reduced the data acquisition time by 57%. It appears that both actuator-assisted cross wire phantom and modified collinear point target phantom calibration approaches are viable options for freehand 3D ultrasound calibration.

  10. Ultrasound-guided versus surgical transversus abdominis plane block in obese patients following caesarean section: a prospective randomised study

    OpenAIRE

    Urfalıoğlu, Aykut; Bakacak, Murat; Boran, Ömer Faruk; Yazar, Fatih Mehmet; Arslan, Mahmut; Öksüz, Hafize

    2016-01-01

    Abstract Background and objectives Ultrasound-guided transversus abdominis plane block demonstrated efficacy in providing post-operative analgesia by prolonging the time to first analgesic requirement and reducing the total analgesic consumption. The surgical transversus abdominis plane block, a novel technique, can be performed safely in obese patients in whom muscle layers cannot be sufficiently exposed. Here, we compared applicability, efficacy and complications of surgical transversus ab...

  11. Field: A Program for Simulating Ultrasound Systems

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    1997-01-01

    A program for the simulation of ultrasound systems is presented.It is based on the Tupholme-Stepanishen method, and is fastbecause of the use of a far-field approximation. Any kind oftransducer geometry and excitation can be simulated, and bothpulse-echo and continuous wave fields can be calculated...... for bothtransmit and pulse-echo. Dynamic apodization and focusing arehandled through time lines, and different focusingschemes can be simulated. The versatility of the program isensured by interfacing it to Matlab. All routines are calleddirectly from Matlab, and all Matlab features can be used. Thismakes...

  12. Sampling system for in vivo ultrasound images

    DEFF Research Database (Denmark)

    Jensen, Jorgen Arendt; Mathorne, Jan

    1991-01-01

    Newly developed algorithms for processing medical ultrasound images use the high frequency sampled transducer signal. This paper describes demands imposed on a sampling system suitable for acquiring such data and gives details about a prototype constructed. It acquires full clinical images...... at a sampling frequency of 20 MHz with a resolution of 12 bits. The prototype can be used for real time image processing. An example of a clinical in vivo image is shown and various aspects of the data acquisition process are discussed....

  13. Ultrasound

    Science.gov (United States)

    Ultrasound is a useful procedure for monitoring the baby's development in the uterus. Ultrasound uses inaudible sound waves to produce a two-dimensional image of the baby while inside the mother's ...

  14. Endoscopic ultrasound-guided pancreaticobiliary intervention in patients with surgically altered anatomy and inaccessible papillae: A review of current literature

    Science.gov (United States)

    Martin, Aaron; Kistler, Charles Andrew; Wrobel, Piotr; Yang, Juliana F.; Siddiqui, Ali A.

    2016-01-01

    The management of pancreaticobiliary disease in patients with surgically altered anatomy is a growing problem for gastroenterologists today. Over the years, endoscopic ultrasound (EUS) has emerged as an important diagnostic and therapeutic modality in the treatment of pancreaticobiliary disease. Patient anatomy has become increasingly complex due to advances in surgical resection of pancreaticobiliary disease and EUS has emerged as the therapy of choice when endoscopic retrograde cholangiopancreatography failed cannulation or when the papilla is inaccessible such as in gastric obstruction or duodenal obstruction. The current article gives a comprehensive review of the current literature for EUS-guided intervention of the pancreaticobiliary tract in patients with altered surgical anatomy. PMID:27386471

  15. Surgical Workflow Analysis: Ideal Application of Navigated Linear Array Ultrasound in Low-Grade Glioma Surgery.

    Science.gov (United States)

    Lothes, Thomas Ernst; Siekmann, Max; König, Ralph Werner; Wirtz, Christian Rainer; Coburger, Jan

    2016-11-01

    Background  Intraoperative imaging in low-grade glioma (LGG) surgery can facilitate residual tumor control and improve surgical outcome. The aim of the study was to evaluate the ideal application and typical interactions of intraoperative MRI (iMRI), conventional low-frequency intraoperative ultrasound (cioUS), and high-frequency linear array intraoperative ultrasound (lioUS) to optimize surgical workflow. Methods  Prospectively, we included 11 patients with an LGG. Typical procedural workflow in the iMRI suite was recorded with a compatible software. We took notes of duration, frequency of application, the surgeon's evaluation of image quality, and the respective benefit of lioUS (15 MHz), cioUS (7 MHz), and iMRI (1.5 T). With the help of the workflow software, we meticulously analyzed ∼ 55 hours of surgery. Results  During the interventions, lioUS was used more often (76.3%) than cioUS (23.7%) and showed a better mean image quality (1 = best to 6 = worst) of 2.08 versus 3.26 with cioUS. The benefit of the lioUS application was rated with an average of 2.27, whereas the cioUS probe only reached a mean value of 3.83. The most common application of lioUS was resection control (42.6%); cioUS was used mainly for orientation (63.2%). Overall, lioUS was used more often and was rated better for both the purposes just described regarding image quality and benefit. Estimated residual tumor based on lioUS alone was lower than the final residual tumor detected with iMRI (7.5% versus 14.5%). The latter technique was rated as the best imaging modality for resection control in all cases followed by lioUS. Conclusion  We provide proof of principle for workflow assessment in cranial neurosurgery. Although iMRI remains the imaging method of choice, lioUS has shown to be beneficial in a combined setup. Evaluation of lioUS was significantly superior to cioUS in most indications except for subcortical lesions. Georg Thieme Verlag KG Stuttgart · New York.

  16. Systems for tracking minimally invasive surgical instruments.

    Science.gov (United States)

    Chmarra, M K; Grimbergen, C A; Dankelman, J

    2007-01-01

    Minimally invasive surgery (e.g. laparoscopy) requires special surgical skills, which should be objectively assessed. Several studies have shown that motion analysis is a valuable assessment tool of basic surgical skills in laparoscopy. However, to use motion analysis as the assessment tool, it is necessary to track and record the motions of laparoscopic instruments. This article describes the state of the art in research on tracking systems for laparoscopy. It gives an overview on existing systems, on how these systems work, their advantages, and their shortcomings. Although various approaches have been used, none of the tracking systems to date comes out as clearly superior. A great number of systems can be used in training environment only, most systems do not allow the use of real laparoscopic instruments, and only a small number of systems provide force feedback.

  17. Transperineal Ultrasound as a Tool to Plan Surgical Strategies in Pediatric Urology: Back to the Future?

    Science.gov (United States)

    de Jesus, Lisieux Eyer; Fazecas, Tatiana; Ribeiro, Bianca G; Dekermacher, Samuel

    2017-06-01

    To demonstrate the usefulness and advantages of transperineal ultrasound (TPUS) on planning the surgical tactics to treat childhood pelviperineal disease (CPPD). A cohort of CPPD is reviewed to provide a pictorial review of TPUS as imaging method variety of CPPD. Other imaging methods are compared with TPUS. TPUS studies of patients showing different conditions on the spectrum of pelviperineal malformation are shown in detail (pictorial review, graphically shown-see figures in the article and as supplementary material), highlighting the advantages of the method and comparing TPUS findings with other imaging techniques. Magnetic resonance imaging, contrast genitograms, voiding cystourethrography, and genital or urologic endoscopy have some important disadvantages, especially radiation exposure, high cost, not easily available equipment, and the need of general anesthesia or deep sedation in children. TPUS is easily available, including in impoverished environments, portable, painless, reproducible, inexpensive, and capable of providing detailed and specific information about pelviperineal malformation with accuracy. Data provided by TPUS are comparable with other imaging techniques (Table 1). Its main disadvantage is the dependency on the expertise of the operator to obtain high-quality, well-interpreted images. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Ultrasound-guided versus surgical transversus abdominis plane block in obese patients following cesarean section: a prospective randomised study

    Directory of Open Access Journals (Sweden)

    Aykut Urfalıoğlu

    Full Text Available Abstract Background and objectives Ultrasound-guided transversus abdominis plane block demonstrated efficacy in providing post-operative analgesia by prolonging the time to first analgesic requirement and reducing the total analgesic consumption. The surgical transversus abdominis plane block, a novel technique, can be performed safely in obese patients in whom muscle layers cannot be sufficiently exposed. Here, we compared applicability, efficacy and complications of surgical transversus abdominis plane and ultrasound-guided transversus abdominis plane blocks in obese pregnant women following cesarean section under general anesthesia. Methods Seventy-five pregnant women with pre- and post-pregnancy body mass index > 30 were randomized and allocated into two groups: Ultrasound-guided transversus abdominis plane block (UT group; n = 38 and surgical TAP block (ST group; n = 37. Visual analogue scale scores at post-operative 0, 2, 6, 12 and 24 hours (h, time to first analgesic requirement, total analgesic consumption amount in 24 h, post-operative side effects, complications and patient satisfaction were recorded. Results and conclusions Age, American Society of Anesthesiologist score, operative duration, body mass index, mean time to first analgesic requirement and total analgesic consumption in 24 h were similar between groups, while significant differences in pre- and post-pregnancy body mass index were observed between groups. Block procedure durations were 7 and 10 minutes in ST and UT groups, respectively. No significant differences in visual analogue scale scores were observed between the groups at all times; itching and nausea was observed in one (UT group and four (UT and ST groups patients, respectively. Surgical transversus abdominis plane block was safe in obese pregnant patients and provided similar post-operative analgesia to ultrasound-guided transversus abdominis plane block.

  19. Peritendinous calcinosis of calcaneus tendon associated with dermatomyositis: correlation between conventional radiograph, ultrasound, magnetic resonance imaging and gross surgical pathology

    International Nuclear Information System (INIS)

    Rosa, Ana Claudia Ferreira; Gomide, Lidyane Marques de Paula; Lemes, Marcella Stival

    2006-01-01

    Interstitial calcinosis is an uncommon condition in which there is either localized or widely disseminated deposition of calcium in the skin, subcutaneous tissues, muscles, and tendons. Calcinosis is often associated with collagen diseases, scleroderma and dermatomyositis. The authors report a case of interstitial calcinosis associated with dermatomyositis studied with conventional radiograph, ultrasound and magnetic resonance imaging, and correlate the imaging findings with the results of surgical pathology gross examination. (author)

  20. Investing in a Surgical Outcomes Auditing System

    Science.gov (United States)

    Bermudez, Luis; Trost, Kristen; Ayala, Ruben

    2013-01-01

    Background. Humanitarian surgical organizations consider both quantity of patients receiving care and quality of the care provided as a measure of success. However, organizational efficacy is often judged by the percent of resources spent towards direct intervention/surgery, which may discourage investment in an outcomes monitoring system. Operation Smile's established Global Standards of Care mandate minimum patient followup and quality of care. Purpose. To determine whether investment of resources in an outcomes monitoring system is necessary and effectively measures success. Methods. This paper analyzes the quantity and completeness of data collected over the past four years and compares it against changes in personnel and resources assigned to the program. Operation Smile began investing in multiple resources to obtain the missing data necessary to potentially implement a global Surgical Outcomes Auditing System. Existing personnel resources were restructured to focus on postoperative program implementation, data acquisition and compilation, and training materials used to educate local foundation and international employees. Results. An increase in the number of postoperative forms and amount of data being submitted to headquarters occurred. Conclusions. Humanitarian surgical organizations would benefit from investment in a surgical outcomes monitoring system in order to demonstrate success and to ameliorate quality of care. PMID:23401763

  1. A passive wireless ultrasound pitch–catch system

    International Nuclear Information System (INIS)

    Zahedi, F; Yao, J; Huang, H

    2015-01-01

    This paper exploits amplitude modulation and demodulation to achieve a passive wireless ultrasound pitch–catch system consisting of a wireless interrogator and a combination of a wireless actuator and a sensor mounted on a structure. The wireless interrogator operates in two modes, i.e. the generation and sensing modes. At the generation mode, the interrogator transmits two microwave signals; one is amplitude modulated with the ultrasound excitation signal while the other is a continuous-wave carrier signal. Once received by the wireless actuator, the amplitude modulated signal is demodulated using the carrier signal to recover the ultrasound excitation signal, which is then supplied to a piezoelectric wafer actuator for ultrasound generation. Subsequently, the interrogator is switched to the sensing mode by transmitting a carrier signal with a different frequency. Once received by the wireless sensor, this carrier signal is modulated with the ultrasound sensing signal acquired by the piezoelectric wafer sensor to produce an amplitude modulated microwave signal, which can then be wirelessly transmitted and demodulated by the interrogator to recover the original ultrasound sensing signal. The principle and implementation of the wireless ultrasound pitch–catch system as well as the data processing of the wirelessly received sensing signal are described. Experiment results validating wireless ultrasound generation and sensing from a distance of 0.5 m are presented. (paper)

  2. A thermocouple thermometry system for ultrasound hyperthermia

    International Nuclear Information System (INIS)

    Ozarka, M.; Gharakhani, A.; Magin, R.; Cain, C.

    1984-01-01

    A thermometry system designed to be used in the treatment of cancer by ultrasound hyperthermia is described. The system monitors tumor temperatures using 16 type T (copper-constantan) thermocouples and is controlled by a 12 MHz Intel 8031 microcomputer. An analog circuit board contains the thermocouple amplifiers, an analog multiplexer, scaling circuitry, and an analog to digital converter. A digital board contains the Intel 8031, program memory, data memory, as well as circuitry for control and data communications. Communication with the hyperthermia system control computer is serially by RS-232 with selectable baud rate. Since the thermocouple amplifiers may have slight differences in gain and offset, a calibrated offset is added to a lookup table value to obtain the proper display temperature to within +- 0.1 0 C. The calibration routine, implemented in software, loads a nonvolatile random access memory chip with the proper offset values based on the outputs of each thermocouple channel at known temperatures which bracket a range of interest

  3. Development of haptic system for surgical robot

    Science.gov (United States)

    Gang, Han Gyeol; Park, Jiong Min; Choi, Seung-Bok; Sohn, Jung Woo

    2017-04-01

    In this paper, a new type of haptic system for surgical robot application is proposed and its performances are evaluated experimentally. The proposed haptic system consists of an effective master device and a precision slave robot. The master device has 3-DOF rotational motion as same as human wrist motion. It has lightweight structure with a gyro sensor and three small-sized MR brakes for position measurement and repulsive torque generation, respectively. The slave robot has 3-DOF rotational motion using servomotors, five bar linkage and a torque sensor is used to measure resistive torque. It has been experimentally demonstrated that the proposed haptic system has good performances on tracking control of desired position and repulsive torque. It can be concluded that the proposed haptic system can be effectively applied to the surgical robot system in real field.

  4. Security of patient data when decommissioning ultrasound systems.

    Science.gov (United States)

    Moggridge, James

    2017-02-01

    Although ultrasound systems generally archive to Picture Archiving and Communication Systems (PACS), their archiving workflow typically involves storage to an internal hard disk before data are transferred onwards. Deleting records from the local system will delete entries in the database and from the file allocation table or equivalent but, as with a PC, files can be recovered. Great care is taken with disposal of media from a healthcare organisation to prevent data breaches, but ultrasound systems are routinely returned to lease companies, sold on or donated to third parties without such controls. In this project, five methods of hard disk erasure were tested on nine ultrasound systems being decommissioned: the system's own delete function; full reinstallation of system software; the manufacturer's own disk wiping service; open source disk wiping software for full and just blank space erasure. Attempts were then made to recover data using open source recovery tools. All methods deleted patient data as viewable from the ultrasound system and from browsing the disk from a PC. However, patient identifiable data (PID) could be recovered following the system's own deletion and the reinstallation methods. No PID could be recovered after using the manufacturer's wiping service or the open source wiping software. The typical method of reinstalling an ultrasound system's software may not prevent PID from being recovered. When transferring ownership, care should be taken that an ultrasound system's hard disk has been wiped to a sufficient level, particularly if the scanner is to be returned with approved parts and in a fully working state.

  5. Ultrasound

    Science.gov (United States)

    ... completed. Young children may need additional preparation. When scheduling an ultrasound for yourself or your child, ask ... of Privacy Practices Notice of Nondiscrimination Manage Cookies Advertising Mayo Clinic is a not-for-profit organization ...

  6. Ultrasound

    Science.gov (United States)

    ... reflect off body structures. A computer receives the waves and uses them to create a picture. Unlike with an x-ray or CT scan, this test does not use ionizing radiation. The test is done in the ultrasound ...

  7. FY1995 development of a endoscopic surgical system utilizing multi-modal functional images; 1995 nendo tashu kino gazo wo mochiiru teishinshu naishikyo shujutsu system no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-05-01

    The purpose of this study is to develop an endoscope system for neurosurgery that can provide not only conventional endoscopic images but also ultraviolet-visible spectra, fluorescence spectra, near infrared spectra, and ultra-soundimages of tissue aiming for real-time identification of pathological tissue. The system also incorporates surgical manipulator and devices such as micro forceps and laser surgical instruments for endoscopic image guided surgery. Surgical Manipulator should be a high performance and easy to operate surgical instrument as well as conventional surgical tools such as scissors and knife. Since living tissue deforms during surgical operation, pre-operative three dimensional information for registration of pathological tissue should be modified based on information obtained during surgery. Thus surgical manipulator should be operated under guidance of surgeon's observation. Consequently, surgical manipulator should have various types of imaging and measurement devices such as an endoscope and an ultrasound imaging probe at its end effectors. Based on this concept, a prototype of a new multi channel surgical manipulator system CM cube (CM3, Computer aided Micro Multichannel Manipulator) that has various types of imaging and measurement devices such as ultra-violet-visible camera for spectroscopic measurement, ultra-sound imaging probe, three dimensional endoscope, together with micro surgical instruments and laser surgical systems has been developed. Its performance was evaluated through in vitro/in vivo experiments and clinical application. (NEDO)

  8. An ultrasound system for simultaneous ultrasound hyperthermia and photon beam irradiation

    International Nuclear Information System (INIS)

    Straube, William L.; Moros, Eduardo G.; Low, Daniel A.; Klein, Eric E.; Willcut, Virgil M.; Myerson, Robert J.

    1996-01-01

    Purpose: An existing ultrasound system has been adapted for simultaneous use with external photon beam irradiation. The system is being used to investigate the potential for increased biological benefit of simultaneously combined hyperthermia and external beam irradiation with currently achievable temperature distributions. Methods and Materials: An existing clinical ultrasound system has been modified for simultaneous operation with a 60 Co teletherapy machine. The generator, thermometry system, computer, and applicators are located inside the treatment room, while the monitor and system control are located at the control console. Two approaches have been used clinically to combine the two modalities. In the first approach, an en-face setup is used in which the ultrasound beam and the photon beam travel through the same window of entry to the tumor. This is achieved by a reflecting system designed to deflect the ultrasound to the tumor while positioning the ultrasound transducer outside the radiation beam. The reflecting system consists of water and water-equivalent materials except for a 1 mm sheet of polished brass that is used as the reflector. The relative pressure fields were measured in water at the same distance from the ultrasound source using a scanning hydrophone with and without the reflector at the two operating frequencies of the device (1.0 and 3.4 MHz) for two applicators. Radiation dosimetry measurements were performed to determine the relationship between 60 Co irradiation through the reflector and absorbed dose. In the second approach the ultrasound and the radiation beam travel into the tumor from different windows of entry such that the radiation beam passes through no portion of the water bolus prior to entering the patient. We have termed this approach the orthogonal approach. For both approaches, the radiation fraction is given in the middle of an uninterrupted 60-min hyperthermia treatment. Results: The system modifications did not impair

  9. Therapeutic ultrasound

    International Nuclear Information System (INIS)

    Crum, Lawrence A

    2004-01-01

    The use of ultrasound in medicine is now quite commonplace, especially with the recent introduction of small, portable and relatively inexpensive, hand-held diagnostic imaging devices. Moreover, ultrasound has expanded beyond the imaging realm, with methods and applications extending to novel therapeutic and surgical uses. These applications broadly include: tissue ablation, acoustocautery, lipoplasty, site-specific and ultrasound mediated drug activity, extracorporeal lithotripsy, and the enhancement of natural physiological functions such as wound healing and tissue regeneration. A particularly attractive aspect of this technology is that diagnostic and therapeutic systems can be combined to produce totally non-invasive, imageguided therapy. This general lecture will review a number of these exciting new applications of ultrasound and address some of the basic scientific questions and future challenges in developing these methods and technologies for general use in our society. We shall particularly emphasize the use of High Intensity Focused Ultrasound (HIFU) in the treatment of benign and malignant tumors as well as the introduction of acoustic hemostasis, especially in organs which are difficult to treat using conventional medical and surgical techniques. (amum lecture)

  10. Ultrasound Picture Archiving And Communication Systems

    Science.gov (United States)

    Koestner, Ken; Hottinger, C. F.

    1982-01-01

    The ideal ultrasonic image communication and storage system must be flexible in order to optimize speed and minimize storage requirements. Various ultrasonic imaging modalities are quite different in data volume and speed requirements. Static imaging, for example B-Scanning, involves acquisition of a large amount of data that is averaged or accumulated in a desired manner. The image is then frozen in image memory before transfer and storage. Images are commonly a 512 x 512 point array, each point 6 bits deep. Transfer of such an image over a serial line at 9600 baud would require about three minutes. Faster transfer times are possible; for example, we have developed a parallel image transfer system using direct memory access (DMA) that reduces the time to 16 seconds. Data in this format requires 256K bytes for storage. Data compression can be utilized to reduce these requirements. Real-time imaging has much more stringent requirements for speed and storage. The amount of actual data per frame in real-time imaging is reduced due to physical limitations on ultrasound. For example, 100 scan lines (480 points long, 6 bits deep) can be acquired during a frame at a 30 per second rate. In order to transmit and save this data at a real-time rate requires a transfer rate of 8.6 Megabaud. A real-time archiving system would be complicated by the necessity of specialized hardware to interpolate between scan lines and perform desirable greyscale manipulation on recall. Image archiving for cardiology and radiology would require data transfer at this high rate to preserve temporal (cardiology) and spatial (radiology) information.

  11. Design and development of an ultrasound calibration phantom and system

    Science.gov (United States)

    Cheng, Alexis; Ackerman, Martin K.; Chirikjian, Gregory S.; Boctor, Emad M.

    2014-03-01

    Image-guided surgery systems are often used to provide surgeons with informational support. Due to several unique advantages such as ease of use, real-time image acquisition, and no ionizing radiation, ultrasound is a common medical imaging modality used in image-guided surgery systems. To perform advanced forms of guidance with ultrasound, such as virtual image overlays or automated robotic actuation, an ultrasound calibration process must be performed. This process recovers the rigid body transformation between a tracked marker attached to the ultrasound transducer and the ultrasound image. A phantom or model with known geometry is also required. In this work, we design and test an ultrasound calibration phantom and software. The two main considerations in this work are utilizing our knowledge of ultrasound physics to design the phantom and delivering an easy to use calibration process to the user. We explore the use of a three-dimensional printer to create the phantom in its entirety without need for user assembly. We have also developed software to automatically segment the three-dimensional printed rods from the ultrasound image by leveraging knowledge about the shape and scale of the phantom. In this work, we present preliminary results from using this phantom to perform ultrasound calibration. To test the efficacy of our method, we match the projection of the points segmented from the image to the known model and calculate a sum squared difference between each point for several combinations of motion generation and filtering methods. The best performing combination of motion and filtering techniques had an error of 1.56 mm and a standard deviation of 1.02 mm.

  12. SAGES TAVAC safety and effectiveness analysis: da Vinci ® Surgical System (Intuitive Surgical, Sunnyvale, CA).

    Science.gov (United States)

    Tsuda, Shawn; Oleynikov, Dmitry; Gould, Jon; Azagury, Dan; Sandler, Bryan; Hutter, Matthew; Ross, Sharona; Haas, Eric; Brody, Fred; Satava, Richard

    2015-10-01

    The da Vinci(®) Surgical System (Intuitive Surgical, Sunnyvale, CA, USA) is a computer-assisted (robotic) surgical system designed to enable and enhance minimally invasive surgery. The Food and Drug Administration (FDA) has cleared computer-assisted surgical systems for use by trained physicians in an operating room environment for laparoscopic surgical procedures in general, cardiac, colorectal, gynecologic, head and neck, thoracic and urologic surgical procedures. There are substantial numbers of peer-reviewed papers regarding the da Vinci(®) Surgical System, and a thoughtful assessment of evidence framed by clinical opinion is warranted. The SAGES da Vinci(®) TAVAC sub-committee performed a literature review of the da Vinci(®) Surgical System regarding gastrointestinal surgery. Conclusions by the sub-committee were vetted by the SAGES TAVAC Committee and SAGES Executive Board. Following revisions, the document was evaluated by the TAVAC Committee and Executive Board again for final approval. Several conclusions were drawn based on expert opinion organized by safety, efficacy, and cost for robotic foregut, bariatric, hepatobiliary/pancreatic, colorectal surgery, and single-incision cholecystectomy. Gastrointestinal surgery with the da Vinci(®) Surgical System is safe and comparable, but not superior to standard laparoscopic approaches. Although clinically acceptable, its use may be costly for select gastrointestinal procedures. Current data are limited to the da Vinci(®) Surgical System; further analyses are needed.

  13. Ultrasound Guided Needle Aspiration versus Surgical Drainage in the management of breast abscesses: a Ugandan experience

    Directory of Open Access Journals (Sweden)

    Chandika Alphonce B

    2012-01-01

    Full Text Available Abstract Background Despite breast abscess becoming less common in developed countries, it has remained one of the leading causes of morbidity in women in developing countries. A randomized controlled trial was conducted at Mulago hospital complex in Kampala Uganda to establish whether ultrasound guided needle aspiration is a feasible alternative treatment option for breast abscesses. Results A total of 65 females with breast abscess were analyzed, of these 33 patients were randomized into the ultrasound guided needle aspiration and 32 patients in the Incision and drainage arm. The mean age was 23.12, most of them were lactating (66.2%, primipararous (44.6% with peripheral abscesses (73.8% located in the upper lateral quadrant (56%.The mean breast size was 3.49 cm. The two groups were comparably in demographic characteristic and breast abscess size. Survival analysis showed no difference in breast abscess healing rate between the two groups (Log rank 0.24 df 1 and P = 0.63. Incision and drainage was found to be more costly than ultrasound guided aspiration (cost effective ratio of 2.85. Conclusion Ultrasound guided needle aspiration is therefore a feasible and cost effective treatment option for both lactating and non lactating breast abscesses with a diameter up to 5 cm by ultrasound in an immune competent patient

  14. Ultrasound Vector Flow Imaging: Part II: Parallel Systems

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Nikolov, Svetoslav Ivanov; Yu, Alfred C. H.

    2016-01-01

    The paper gives a review of the current state-of-theart in ultrasound parallel acquisition systems for flow imaging using spherical and plane waves emissions. The imaging methods are explained along with the advantages of using these very fast and sensitive velocity estimators. These experimental...... ultrasound imaging for studying brain function in animals. The paper explains the underlying acquisition and estimation methods for fast 2-D and 3-D velocity imaging and gives a number of examples. Future challenges and the potentials of parallel acquisition systems for flow imaging are also discussed....

  15. Imaging of foreign bodies in the face and ultrasound guided surgical removal; Diagnostico por imagem de corpos estranhos da face e retirada cirurgica guiada por ultra-sonografia

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Claudio Marcio Amaral de Oliveira; Gambin, Moises; Ribeiro, Erica Barreiros; Amarante Junior, Jose Luiz de Medeiros [Hospital Naval Marcilio Dias, Rio de Janeiro, RJ (Brazil)]. E-mail: cmaol@br.inter.net; cmaolima@hotmail.com; Monteiro, Alexandra Maria Vieira [Pontificia Univ. Catolica do Rio de Janeiro (PUC/Rio), RJ (Brazil). Curso de Pos-Graduacao em Radiologia

    2006-10-15

    The identification and surgical removal of foreign bodies is a complex procedure in medical practice, principally when the involved material is radiolucent. The technological advent of the ultrasonography equipment comes enlarging the field of application of this method more and more, in medical practice. The authors describe a case of an ultrasound guided surgical removal of glass fragments from the face of a patient. The foreign bodies were previously diagnosed by ultrasound and computed tomography. The guided technic showed secure, less invasive and efficient, allowing the retreat of all the fragments. (author)

  16. Real-Time Implementation of Medical Ultrasound Strain Imaging System

    International Nuclear Information System (INIS)

    Jeong, Mok Kun; Kwon, Sung Jae; Bae, Moo Ho

    2008-01-01

    Strain imaging in a medical ultrasound imaging system can differentiate the cancer or tumor in a lesion that is stiffer than the surrounding tissue. In this paper, a strain imaging technique using quasistatic compression is implemented that estimates the displacement between pre- and postcompression ultrasound echoes and obtains strain by differentiating it in the spatial direction. Displacements are computed from the phase difference of complex baseband signals obtained using their autocorrelation, and errors associated with converting the phase difference into time or distance are compensated for by taking into the center frequency variation. Also, to reduce the effect of operator's hand motion, the displacements of all scanlines are normalized with the result that satisfactory strain image quality has been obtained. These techniques have been incorporated into implementing a medical ultrasound strain imaging system that operates in real time.

  17. [The rational application of Da Vinci surgical system in thyroidectomy].

    Science.gov (United States)

    He, Q Q

    2017-08-01

    Da Vinci surgical system is the most advanced minimally invasive surgical platform in the world, and this system has been widely used in cardiac surgery, urology surgery, gynecologic surgery and general surgery. Although the application of this system was relatively late in thyroid surgery, the number of thyroidectomy with Da Vinci surgical system is increasing quickly. Having reviewed recent studies and summarized clinical experience, compared with traditional open operation, the robotic thyroidectomy has the same surgical safety and effectiveness in selective patients with thyroid cancer. In this paper, several aspects on this novel operation were demonstrated, including surgical indications and contraindications, the approaches, surgical procedures and postoperative complications, in order to promote the rational application of Da Vinci surgical system in thyroidectomy.

  18. A Portable Ultrasound System for Non-Invasive Ultrasonic Neuro-Stimulation.

    Science.gov (United States)

    Qiu, Weibao; Zhou, Juan; Chen, Yan; Su, Min; Li, Guofeng; Zhao, Huixia; Gu, Xianyi; Meng, De; Wang, Congzhi; Xiao, Yang; Lam, Kwok Ho; Dai, Jiyan; Zheng, Hairong

    2017-12-01

    Fundamental insights into the function of the neural circuits often follows from the advances in methodologies and tools for neuroscience. Electrode- and optical- based stimulation methods have been used widely for neuro-modulation with high resolution. However, they are suffering from inherent invasive surgical procedure. Ultrasound has been proved as a promising technology for neuro-stimulation in a non-invasive manner. However, no portable ultrasound system has been developed particularly for neuro-stimulation. The utilities used currently are assembled by traditional functional generator, power amplifier, and general transducer, therefore, resulting in lack of flexibility. This paper presents a portable system to achieve ultrasonic neuro-stimulation to satisfy various studies. The system incorporated a high voltage waveform generator and a matching circuit that were optimized for neuro-stimulation. A new switching mode power amplifier was designed and fabricated. The noise generated by the power amplifier was reduced (about 30 dB), and the size and weight were smaller in contrast with commercial equipment. In addition, a miniaturized ultrasound transducer was fabricated using Pb(Mg 1/3 Nb 2/3 )O 3 -PbTiO 3 (PMN-PT) 1-3 composite single crystal for the improved ultrasonic performance. The spatial peak temporal average pressure was higher than 250 kPa in the range of 0.5-5 MHz. In vitro and in vivo studies were conducted to show the performance of the system.

  19. Surgical treatment for mediastinal abscess induced by endobronchial ultrasound-guided transbronchial needle aspiration: a case report and literature review.

    Science.gov (United States)

    Yokoyama, Yujiro; Nakagomi, Takahiro; Shikata, Daichi; Higuchi, Rumi; Oyama, Toshio; Goto, Taichiro

    2017-07-14

    Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a useful and less invasive procedure for the definitive diagnosis of mediastinal and hilar lymph nodes. However, infectious complications can occur after EBUS-TBNA, although they are extremely rare. A 66-year-old man with necrotic and swollen lower paratracheal lymph nodes underwent EBUS-TBNA. A mediastinal abscess developed 9 days post-procedure. Surgical drainage and debridement of the abscess were performed along with lymph node biopsy followed by daily washing of the thoracic cavity. Surgical treatment was effective, leading to remission of the abscess. Biopsy revealed that the tumor was squamous cell carcinoma with no radiologically detected cancer elsewhere in the body. Mediastinal lung cancer was thus confirmed. Subsequent chemoradiotherapy led to the remission of the tumor. Mediastinitis after EBUS-TBNA is rare but should be considered, particularly if the target lymph nodes are necrotic. Mediastinitis can lead to serious and rapid deterioration of the patient's condition, for which surgical intervention is the treatment of choice.

  20. CISUS: an integrated 3D ultrasound system for IGT using a modular tracking API

    Science.gov (United States)

    Boctor, Emad M.; Viswanathan, Anand; Pieper, Steve; Choti, Michael A.; Taylor, Russell H.; Kikinis, Ron; Fichtinger, Gabor

    2004-05-01

    Ultrasound has become popular in clinical/surgical applications, both as the primary image guidance modality and also in conjunction with other modalities like CT or MRI. Three dimensional ultrasound (3DUS) systems have also demonstrated usefulness in image-guided therapy (IGT). At the same time, however, current lack of open-source and open-architecture multi-modal medical visualization systems prevents 3DUS from fulfilling its potential. Several stand-alone 3DUS systems, like Stradx or In-Vivo exist today. Although these systems have been found to be useful in real clinical setting, it is difficult to augment their functionality and integrate them in versatile IGT systems. To address these limitations, a robotic/freehand 3DUS open environment (CISUS) is being integrated into the 3D Slicer, an open-source research tool developed for medical image analysis and surgical planning. In addition, the system capitalizes on generic application programming interfaces (APIs) for tracking devices and robotic control. The resulting platform-independent open-source system may serve as a valuable tool to the image guided surgery community. Other researchers could straightforwardly integrate the generic CISUS system along with other functionalities (i.e. dual view visualization, registration, real-time tracking, segmentation, etc) to rapidly create their medical/surgical applications. Our current driving clinical application is robotically assisted and freehand 3DUS-guided liver ablation, which is fully being integrated under the CISUS-3D Slicer. Initial functionality and pre-clinical feasibility are demonstrated on phantom and ex-vivo animal models.

  1. Application of da Vinci surgical robotic system in hepatobiliary surgery

    Directory of Open Access Journals (Sweden)

    Chen Jiahai

    2018-01-01

    Full Text Available The development of minimally invasive surgery has brought a revolutionary change to surgery techniques, and endoscopic surgical robots, especially Da Vinci robotic surgical system, has further broaden the scope of minimally invasive surgery, which has been applied in a variety of surgical fields including hepatobiliary surgery. Today, the application of Da Vinci surgical robot can cover most of the operations in hepatobiliary surgery which has proved to be safe and practical. What’s more, many clinical studies in recent years have showed that Da Vinci surgical system is superior to traditional laparoscopy. This paper summarize the advantage and disadvantage of Da Vinci surgical system, and outlines the current status of and future perspectives on the robot-assisted hepatobiliary surgery based on the cases reports in recent years of the application of Da Vinci surgical robot.

  2. Systems for tracking minimally invasive surgical instruments

    NARCIS (Netherlands)

    Chmarra, M. K.; Grimbergen, C. A.; Dankelman, J.

    2007-01-01

    Minimally invasive surgery (e.g. laparoscopy) requires special surgical skills, which should be objectively assessed. Several studies have shown that motion analysis is a valuable assessment tool of basic surgical skills in laparoscopy. However, to use motion analysis as the assessment tool, it is

  3. Development and implementation of ultrasound picture archiving and communication system

    Science.gov (United States)

    Weinberg, Wolfram S.; Tessler, Franklin N.; Grant, Edward G.; Kangarloo, Hooshang; Huang, H. K.

    1990-08-01

    The Department of Radiological Sciences at the UCLA School of Medicine is developing an archiving and communication system (PACS) for digitized ultrasound images. In its final stage the system will involve the acquisition and archiving of ultrasound studies from four different locations including the Center for Health Sciences, the Department for Mental Health and the Outpatient Radiology and Endoscopy Departments with a total of 200-250 patient studies per week. The concept comprises two stages of image manipulation for each ultrasound work area. The first station is located close to the examination site and accomodates the acquisition of digital images from up to five ultrasound devices and provides for instantaneous display and primary viewing and image selection. Completed patient studies are transferred to a main workstation for secondary review, further analysis and comparison studies. The review station has an on-line storage capacity of 10,000 images with a resolution of 512x512 8 bit data to allow for immediate retrieval of active patient studies of up to two weeks. The main work stations are connected through the general network and use one central archive for long term storage and a film printer for hardcopy output. First phase development efforts concentrate on the implementation and testing of a system at one location consisting of a number of ultrasound units with video digitizer and network interfaces and a microcomputer workstation as host for the display station with two color monitors, each allowing simultaneous display of four 512x512 images. The discussion emphasizes functionality, performance and acceptance of the system in the clinical environment.

  4. [Clinical application of Da Vinci surgical system in China].

    Science.gov (United States)

    Jin, Zhenyu

    2014-01-01

    Da Vinci robotic surgical system leads the development of minimally invasive surgical techniques. By using Da Vinci surgical robot for minimally invasive surgery, it brings a lot of advantages to the surgeons. Since 2008, Da Vinci surgeries have been performed in 14 hospitals in domestic cities such as Beijing and Shanghai. Until the end of 2012, 3 551 cases of Da Vinci robotic surgery have been performed, covering various procedures of various surgical departments including the department of general surgery, urology, cardiovascular surgery, thoracic surgery, gynecology, and etc. Robotic surgical technique has made remarkable achievements.

  5. Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey.

    Science.gov (United States)

    Huang, Qinghua; Zhang, Fan; Li, Xuelong

    2018-01-01

    The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD) systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system.

  6. Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey

    Directory of Open Access Journals (Sweden)

    Qinghua Huang

    2018-01-01

    Full Text Available The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system.

  7. A multipoint feedback control system for scanned focussed ultrasound hyperthermia

    International Nuclear Information System (INIS)

    Johnson, C.; Kress, R.; Roemer, R.; Hynynen, K.

    1987-01-01

    A multipoint feedback control system has been developed and tested for use with a scanned focussed ultrasound hyperthermia system. Extensive in-vivo tests (using a perfused organ model) have been made to evaluate the basic performance characteristics of the feedback control scheme for control of temperature in perfused media. The results of these tests are presented and compared with the predictions of a simulation routine. The control scheme was also tested in vivo using dogs' thighs and kidneys. Thigh experiments show the control scheme responds well to the affects of vasodilation and is able to maintain the targeted temperatures. In kidney experiments, where the rate of perfusion was controllable, the power adjusting algorithm successfully maintained uniform temperature distributions across regions of varying rates of perfusion. As a conclusion, the results show that this multipoint feedback controller scheme induces uniform temperature distributions when used with scanned focussed ultrasound systems

  8. Percutaneous ultrasound-guided radiofrequency ablation for kidney tumors in patients with surgical risk

    International Nuclear Information System (INIS)

    Salagierski, Marek; Salagierski, Maciej; Sosnowski, Marek; Salagierska-Barwinska, Anna

    2006-01-01

    The aim of this study was to describe our experience with percutaneous ultrasound-guided radiofrequency ablation of kidney tumors. From July 2002 to August 2005, 45 radiofrequency ablations (RFA) in 42 selected patients with kidney tumor were performed. The patients had either contraindications to surgery procedures or had a solitary kidney. The average tumor size was 37.5 mm (range, 18-59 mm) with the mean age of 68 years (range, 28-83 years). RFA were performed based on radiographic findings. Needle biopsy was made only twice. Monopolar Cool-tip Tyco or bipolar Celon Olympus radiofrequency devices were used. The procedure was performed under conscious sedation with local anesthesia. Treatment efficacy was assessed by computed tomography and by Doppler ultrasound. The absence of contrast enhancement on computed tomography was considered to be a successful treatment. The average follow up was 14 months (range, 3-36 months). In 42 tumors (93%), total absence of contrast enhancement was obtained after the initial RFA and in three tumors (7%) after the second ablation session. There were no complications following 41 procedures, including all ablations in small (<35 mm) renal masses. In four procedures, minor complications were observed. All patients are alive. There has been no need for chronic hemodialysis and, until now, we have not observed any local recurrences with the exception of one metastasis to an ipsilateral adrenal gland. RFA of kidney tumors is a promising alternative treatment which could be considered for patients who are not suitable for surgery. (author)

  9. Error analysis for determination of accuracy of an ultrasound navigation system for head and neck surgery.

    Science.gov (United States)

    Kozak, J; Krysztoforski, K; Kroll, T; Helbig, S; Helbig, M

    2009-01-01

    The use of conventional CT- or MRI-based navigation systems for head and neck surgery is unsatisfactory due to tissue shift. Moreover, changes occurring during surgical procedures cannot be visualized. To overcome these drawbacks, we developed a novel ultrasound-guided navigation system for head and neck surgery. A comprehensive error analysis was undertaken to determine the accuracy of this new system. The evaluation of the system accuracy was essentially based on the method of error definition for well-established fiducial marker registration methods (point-pair matching) as used in, for example, CT- or MRI-based navigation. This method was modified in accordance with the specific requirements of ultrasound-guided navigation. The Fiducial Localization Error (FLE), Fiducial Registration Error (FRE) and Target Registration Error (TRE) were determined. In our navigation system, the real error (the TRE actually measured) did not exceed a volume of 1.58 mm(3) with a probability of 0.9. A mean value of 0.8 mm (standard deviation: 0.25 mm) was found for the FRE. The quality of the coordinate tracking system (Polaris localizer) could be defined with an FLE of 0.4 +/- 0.11 mm (mean +/- standard deviation). The quality of the coordinates of the crosshairs of the phantom was determined with a deviation of 0.5 mm (standard deviation: 0.07 mm). The results demonstrate that our newly developed ultrasound-guided navigation system shows only very small system deviations and therefore provides very accurate data for practical applications.

  10. Transverse vs torsional ultrasound: prospective randomized contralaterally controlled study comparing two phacoemulsification-system handpieces.

    Science.gov (United States)

    Assil, Kerry K; Harris, Lindsay; Cecka, Jeannie

    2015-01-01

    To compare surgical efficiency and multiple early clinical outcome variables in eyes undergoing phacoemulsification using either transversal or torsional ultrasound systems. Assil Eye Institute, Beverly Hills, CA, USA. Prospective, randomized, clinician-masked, contralaterally controlled single-center evaluation. Patients seeking cataract removal in both eyes with implantation of multifocal intraocular lenses were randomly assigned to one of two treatment rooms for phacoemulsification with either a transverse ultrasound system or torsional handpiece system. The contralateral eye was treated at a later date with the alternate device. A total of 54 eyes of 27 patients having similar degrees of cataract, astigmatism, and visual potential were included. All operative data were collected for analysis, and patients were followed for 3 months after surgery. Similar visual acuity was reported at all postoperative visits between the two groups. Mean phacoemulsification time and total power required were both significantly lower with the transverse system than with the torsional technique (Ptransverse system vs torsional (Ptransverse vs torsional. Macular swelling was less at 1 week, 1 month, and 3 months with transverse vs torsional, although the difference did not achieve significance (P=0.1) at any single time point. Clinically detectable corneal edema was reported less frequently at all postoperative time points with the transverse system. The transverse ultrasound system was found to be possibly associated with less balanced salt-solution use, less phacoemulsification time, and less power required than the torsional phaco system. Postoperative data suggested that improved phaco efficiency may translate to a better overall safety profile for the patient.

  11. Ultrasound guided percutaneous cholecystostomy in high-risk patients for surgical intervention.

    Science.gov (United States)

    Bakkaloglu, Huseyin; Yanar, Hakan; Guloglu, Recep; Taviloglu, Korhan; Tunca, Fatih; Aksoy, Murat; Ertekin, Cemalettin; Poyanli, Arzu

    2006-11-28

    To assess the efficacy and safety of ultrasound guided percutaneous cholecystostomy (PC) in the treatment of acute cholecystitis in a well-defined high risk patients under general anesthesia. The data of 27 consecutive patients who underwent percutaneous transhepatic cholecystostomy for the management of acute cholecystitis from January 1999 to June 2003 was retrospectively evaluated. All of the patients had both clinical and sonographic signs of acute cholecystitis and had comorbid diseases. Ultrasound revealed gallbladder stones in 25 patients and acalculous cholecystitis in two patients. Cholecystostomy catheters were removed 14-32 d (mean 23 d) after the procedure in cases where complete regression of all symptoms was achieved. There were statistically significant reductions in leukocytosis, (13.7 x 10(3)+/-1.3 x 10(3) microg/L vs 13 x 10(3)+/-1 x 10(3) microg/L, P extraction was performed successfully with endoscopic retrograde cholangio-pancreatography (ERCP) in three patients. After cholecystostomy, 5 (18%) patients underwent delayed cholecystectomy without any complications. Three out of 22 patients were admitted with recurrent acute cholecystitis during the follow-up and recovered with medical treatment. Catheter dislodgement occurred in three patients spontaneously, and two of them were managed by reinsertion of the catheter. As an alternative to surgery, percutaneous cholecystostomy seems to be a safe method in critically ill patients with acute cholecystitis and can be performed with low mortality and morbidity. Delayed cholecystectomy and ERCP, if needed, can be performed after the acute period has been resolved by percutaneous cholecystostomy.

  12. [Percutaneous ultrasound-guided drainage in the surgical treatment of acute severe pancreatitis].

    Science.gov (United States)

    Delattre, J-F; Levy Chazal, N; Lubrano, D; Flament, J-B

    2004-11-01

    To report results of percutaneous ultrasound-guided drainage, performed by a surgeon, in the treatment of complications of acute pancreatitis (AP), and to determine the role of this technique in the therapeutic armamentarium of severe AP. From 1986 to 2001, 59 patients were included in this retrospective study. All patients initially had severe necrotizing AP (mean Ranson score = 4.1 ; range : 2-7). Anatomical lesions included pancreatic abscess in 6 patients and necrosis in 53 (17 stage D and 36 stage E according to Balthazar's classification). Necrosis was infected in 42 and sterile in 11 respectively. Drainage was performed under ultrasound guidance and local anaesthesia using small-diameter drains (7-14 French). Drainage was performed on average 23 days after onset of AP. Infection was proven by fine-needle aspiration in 47 (80 %) patients (41 infected necrosis and 6 localized abscess). In one patient, culture of aspirated fluid was negative but necrosis was infected (one false negative). Culture of aspirated fluid was negative and necrosis was sterile in 11 patients. Nineteen (32%) patients healed without subsequent surgery: 7 (16%) in the infected necrosis group, 6(55%) in the sterile necrosis group, and 6 (100%) in the abscess group. Forty (68%) patients had subsequent necrosectomy including 8 (14%) who died. Twenty (34 %) digestive fistulas healed spontaneously, except one treated by diversion stomia. Of the 16 (27 %) pancreatic fistulas, 6 needed subsequent interventional treatment. In selected patients, percutaneous drainage can represent an alternative to surgery with a 14% mortality rate. The high rate of subsequent necrosectomy suggests that drains with larger diameter, possibly associated with continuous irrigation, should be used.

  13. Utility of compact ultrasound in a mass surgical selection program in Africa: experience of a sonologist at the MV Africa Mercy Hospital Ship's screening day.

    Science.gov (United States)

    Harris, Robert D; Parker, Gary

    2015-02-01

    Compact ultrasound (US) was introduced in an austere setting with no other available imaging for an annual mass surgical screening day. Compact US examinations were performed on 25 patients from more than 7000 potential patients, as deemed possibly useful by the screening surgeons. Of the 20 patients with recorded data, compact US was helpful in 14 of 20 as a decision-making tool, obviating computed tomography for preoperative planning. Compact US was helpful in most cases, saving resources (computed tomography), technologist time, and radiation risk in this select population. © 2015 by the American Institute of Ultrasound in Medicine.

  14. Evaluation of Chest Ultrasound Integrated Teaching of Respiratory System Physiology to Medical Students

    Science.gov (United States)

    Paganini, Matteo; Bondì, Michela; Rubini, Alessandro

    2017-01-01

    Ultrasound imaging is a widely used diagnostic technique, whose integration in medical education is constantly growing. The aim of this study was to evaluate chest ultrasound usefulness in teaching respiratory system physiology, students' perception of chest ultrasound integration into a traditional lecture in human physiology, and short-term…

  15. Development of a Cognitive Robotic System for Simple Surgical Tasks

    Directory of Open Access Journals (Sweden)

    Riccardo Muradore

    2015-04-01

    Full Text Available The introduction of robotic surgery within the operating rooms has significantly improved the quality of many surgical procedures. Recently, the research on medical robotic systems focused on increasing the level of autonomy in order to give them the possibility to carry out simple surgical actions autonomously. This paper reports on the development of technologies for introducing automation within the surgical workflow. The results have been obtained during the ongoing FP7 European funded project Intelligent Surgical Robotics (I-SUR. The main goal of the project is to demonstrate that autonomous robotic surgical systems can carry out simple surgical tasks effectively and without major intervention by surgeons. To fulfil this goal, we have developed innovative solutions (both in terms of technologies and algorithms for the following aspects: fabrication of soft organ models starting from CT images, surgical planning and execution of movement of robot arms in contact with a deformable environment, designing a surgical interface minimizing the cognitive load of the surgeon supervising the actions, intra-operative sensing and reasoning to detect normal transitions and unexpected events. All these technologies have been integrated using a component-based software architecture to control a novel robot designed to perform the surgical actions under study. In this work we provide an overview of our system and report on preliminary results of the automatic execution of needle insertion for the cryoablation of kidney tumours.

  16. Ultrasound guided percutaneous cholecystostomy in high-risk patients for surgical intervention

    Science.gov (United States)

    Bakkaloglu, Huseyin; Yanar, Hakan; Guloglu, Recep; Taviloglu, Korhan; Tunca, Fatih; Aksoy, Murat; Ertekin, Cemalettin; Poyanli, Arzu

    2006-01-01

    AIM: To assess the efficacy and safety of ultrasound guided percutaneous cholecystostomy (PC) in the treatment of acute cholecystitis in a well-defined high risk patients under general anesthesia. METHODS: The data of 27 consecutive patients who underwent percutaneous transhepatic cholecystostomy for the management of acute cholecystitis from January 1999 to June 2003 was retrospectively evaluated. All of the patients had both clinical and sonographic signs of acute cholecystitis and had comorbid diseases. RESULTS: Ultrasound revealed gallbladder stones in 25 patients and acalculous cholecystitis in two patients. Cholecystostomy catheters were removed 14-32 d (mean 23 d) after the procedure in cases where complete regression of all symptoms was achieved. There were statistically significant reductions in leukocytosis, (13.7 × 103 ± 1.3 × 103 μg/L vs 13 × 103 ± 1 × 103 μg/L, P < 0.05 for 24 h after PC; 13.7 × 103 ± 1.3 × 103 μg/L vs 8.3 × 103 ± 1.2 × 103 μg/L, P < 0.0001 for 72 h after PC), C -reactive protein (51.2 ± 18.5 mg/L vs 27.3 ± 10.4 mg/L, P < 0.05 for 24 h after PC; 51.2 ± 18.5 mg/L vs 5.4 ± 1.5 mg/L, P < 0.0001 for 72 h after PC), and fever (38 ± 0.35°C vs 37.3 ± 0.32°C, P < 0.05 for 24 h after PC; 38 ± 0.35°C vs 36.9 ± 0.15°C, P < 0.0001 for 72 h after PC). Sphincterotomy and stone extraction was performed successfully with endoscopic retrograde cholangio-pancreatography (ERCP) in three patients. After cholecystostomy, 5 (18%) patients underwent delayed cholecystectomy without any complications. Three out of 22 patients were admitted with recurrent acute cholecystitis during the follow-up and recovered with medical treatment. Catheter dislodgement occurred in three patients spontaneously, and two of them were managed by reinsertion of the catheter. CONCLUSION: As an alternative to surgery, percutan-eous cholecystostomy seems to be a safe method in critically ill patients with acute cholecystitis and can be performed with low

  17. Cost comparison between ultrasound-guided 14-g large core breast biopsy and open surgical biopsy: an analysis for Austria.

    Science.gov (United States)

    Gruber, R; Walter, E; Helbich, T H

    2010-06-01

    To examine the budget impact of ultrasound-guided 14-g large core breast biopsy (US-guided LCBB) by comparing the costs of US-guided LCBB and open surgical biopsy (OSB); to calculate the cost savings attributable to US-guided LCBB; and to assess the frequency with which US-guided LCBB obviates the need for an OSB. In a retrospective study, we reviewed 399 suspicious breast lesions on which US-guided LCBB and OSB or, in cases of benign histology, clinical follow-up, were performed. Cost savings were calculated using nationally allowed flat rates (A-drg) and patient charges. Costs were measured from both, a hospital and a socioeconomic perspective. Deterministic sensitivity analyses were simulated to assess the extent of achievable cost savings. Overall cost savings for US-guided LCBB over OSB were euro 977 (euro 2,337/euro 3,314) per case from a hospital perspective, resulting in a total cost decrease of 30% for the diagnosis of suspicious breast lesions. From a socioeconomic perspective, cost savings were euro 1,542 (euro 2,600/euro 4,142) per case, resulting in a 37% reduction in biopsy cost. US-guided LCBB obviated the need for a surgical procedure in 240 (60%) of 399 women. In all four sensitivity analyses, costs of US-guided LCBB remained lower than that of OSB. From an economic perspective, US-guided LCBB is highly recommended for the diagnosis of suspicious breast lesions, as this procedure reduces the cost of diagnosis substantially. In Austria, annual cost savings would be euro 18.5 million. Copyright (c) 2009 Elsevier Ireland Ltd. All rights reserved.

  18. Cost comparison between ultrasound-guided 14-g large core breast biopsy and open surgical biopsy: An analysis for Austria

    Energy Technology Data Exchange (ETDEWEB)

    Gruber, R., E-mail: renate.gruber@meduniwien.ac.a [Medical University of Vienna, Department of Radiology, Division of Molecular and Gender Imaging, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Walter, E. [Institute of Pharmacoeconomic Research, Wolfengasse 4/7, A-1010 Vienna (Austria); Helbich, T.H. [Medical University of Vienna, Department of Radiology, Division of Molecular and Gender Imaging, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2010-06-15

    Purpose: To examine the budget impact of ultrasound-guided 14-g large core breast biopsy (US-guided LCBB) by comparing the costs of US-guided LCBB and open surgical biopsy (OSB); to calculate the cost savings attributable to US-guided LCBB; and to assess the frequency with which US-guided LCBB obviates the need for an OSB. Materials and methods: In a retrospective study, we reviewed 399 suspicious breast lesions on which US-guided LCBB and OSB or, in cases of benign histology, clinical follow-up, were performed. Cost savings were calculated using nationally allowed flat rates (A-drg) and patient charges. Costs were measured from both, a hospital and a socioeconomic perspective. Deterministic sensitivity analyses were simulated to assess the extent of achievable cost savings. Results: Overall cost savings for US-guided LCBB over OSB were Euro 977 ( Euro 2,337/ Euro 3,314) per case from a hospital perspective, resulting in a total cost decrease of 30% for the diagnosis of suspicious breast lesions. From a socioeconomic perspective, cost savings were Euro 1,542 ( Euro 2,600/ Euro 4,142) per case, resulting in a 37% reduction in biopsy cost. US-guided LCBB obviated the need for a surgical procedure in 240 (60%) of 399 women. In all four sensitivity analyses, costs of US-guided LCBB remained lower than that of OSB. Conclusion: From an economic perspective, US-guided LCBB is highly recommended for the diagnosis of suspicious breast lesions, as this procedure reduces the cost of diagnosis substantially. In Austria, annual cost savings would be Euro 18.5 million.

  19. Cost comparison between ultrasound-guided 14-g large core breast biopsy and open surgical biopsy: An analysis for Austria

    International Nuclear Information System (INIS)

    Gruber, R.; Walter, E.; Helbich, T.H.

    2010-01-01

    Purpose: To examine the budget impact of ultrasound-guided 14-g large core breast biopsy (US-guided LCBB) by comparing the costs of US-guided LCBB and open surgical biopsy (OSB); to calculate the cost savings attributable to US-guided LCBB; and to assess the frequency with which US-guided LCBB obviates the need for an OSB. Materials and methods: In a retrospective study, we reviewed 399 suspicious breast lesions on which US-guided LCBB and OSB or, in cases of benign histology, clinical follow-up, were performed. Cost savings were calculated using nationally allowed flat rates (A-drg) and patient charges. Costs were measured from both, a hospital and a socioeconomic perspective. Deterministic sensitivity analyses were simulated to assess the extent of achievable cost savings. Results: Overall cost savings for US-guided LCBB over OSB were Euro 977 ( Euro 2,337/ Euro 3,314) per case from a hospital perspective, resulting in a total cost decrease of 30% for the diagnosis of suspicious breast lesions. From a socioeconomic perspective, cost savings were Euro 1,542 ( Euro 2,600/ Euro 4,142) per case, resulting in a 37% reduction in biopsy cost. US-guided LCBB obviated the need for a surgical procedure in 240 (60%) of 399 women. In all four sensitivity analyses, costs of US-guided LCBB remained lower than that of OSB. Conclusion: From an economic perspective, US-guided LCBB is highly recommended for the diagnosis of suspicious breast lesions, as this procedure reduces the cost of diagnosis substantially. In Austria, annual cost savings would be Euro 18.5 million.

  20. Potential and problems in ultrasound-responsive drug delivery systems

    Directory of Open Access Journals (Sweden)

    Zhao YZ

    2013-04-01

    Full Text Available Ying-Zheng Zhao,1,3 Li-Na Du,2 Cui-Tao Lu,1 Yi-Guang Jin,2 Shu-Ping Ge3 1Wenzhou Medical College, Wenzhou City, Zhejiang Province, 2Department of Pharmaceutical Sciences, Beijing Institute of Radiation Medicine, Beijing, People’s Republic of China; 3St Christopher’s Hospital for Children/Drexel University College of Medicine, Philadelphia, PA, USA Abstract: Ultrasound is an important local stimulus for triggering drug release at the target tissue. Ultrasound-responsive drug delivery systems (URDDS have become an important research focus in targeted therapy. URDDS include many different formulations, such as microbubbles, nanobubbles, nanodroplets, liposomes, emulsions, and micelles. Drugs that can be loaded into URDDS include small molecules, biomacromolecules, and inorganic substances. Fields of clinical application include anticancer therapy, treatment of ischemic myocardium, induction of an immune response, cartilage tissue engineering, transdermal drug delivery, treatment of Huntington’s disease, thrombolysis, and disruption of the blood–brain barrier. This review focuses on recent advances in URDDS, and discusses their formulations, clinical application, and problems, as well as a perspective on their potential use in the future. Keywords: ultrasound, targeted therapy, clinical application

  1. A novel fusion imaging system for endoscopic ultrasound

    DEFF Research Database (Denmark)

    Gruionu, Lucian Gheorghe; Saftoiu, Adrian; Gruionu, Gabriel

    2016-01-01

    BACKGROUND AND OBJECTIVE: Navigation of a flexible endoscopic ultrasound (EUS) probe inside the gastrointestinal (GI) tract is problematic due to the small window size and complex anatomy. The goal of the present study was to test the feasibility of a novel fusion imaging (FI) system which uses...... time was 24.6 ± 6.6 min, while the time to reach the clinical target was 8.7 ± 4.2 min. CONCLUSIONS: The FI system is feasible for clinical use, and can reduce the learning curve for EUS procedures and improve navigation and targeting in difficult anatomic locations....

  2. Ultrasound-guided versus surgical transversus abdominis plane block in obese patients following cesarean section: a prospective randomised study

    Directory of Open Access Journals (Sweden)

    Aykut Urfalıoğlu

    2017-09-01

    Full Text Available Background and objectives: Ultrasound-guided transversus abdominis plane block demonstrated efficacy in providing post-operative analgesia by prolonging the time to first analgesic requirement and reducing the total analgesic consumption. The surgical transversus abdominis plane block, a novel technique, can be performed safely in obese patients in whom muscle layers cannot be sufficiently exposed. Here, we compared applicability, efficacy and complications of surgical transversus abdominis plane and ultrasound-guided transversus abdominis plane blocks in obese pregnant women following cesarean section under general anesthesia. Methods: Seventy-five pregnant women with pre- and post-pregnancy body mass index > 30 were randomized and allocated into two groups: Ultrasound-guided transversus abdominis plane block (UT group; n = 38 and surgical TAP block (ST group; n = 37. Visual analogue scale scores at post-operative 0, 2, 6, 12 and 24 hours (h, time to first analgesic requirement, total analgesic consumption amount in 24 h, post-operative side effects, complications and patient satisfaction were recorded. Results and conclusions: Age, American Society of Anesthesiologist score, operative duration, body mass index, mean time to first analgesic requirement and total analgesic consumption in 24 h were similar between groups, while significant differences in pre- and post-pregnancy body mass index were observed between groups. Block procedure durations were 7 and 10 minutes in ST and UT groups, respectively. No significant differences in visual analogue scale scores were observed between the groups at all times; itching and nausea was observed in one (UT group and four (UT and ST groups patients, respectively. Surgical transversus abdominis plane block was safe in obese pregnant patients and provided similar post-operative analgesia to ultrasound-guided transversus abdominis plane block. Resumo: Justificativa e objetivos: O bloqueio do

  3. Surgical data processing for smart intraoperative assistance systems

    Directory of Open Access Journals (Sweden)

    Stauder Ralf

    2017-09-01

    Full Text Available Different components of the newly defined field of surgical data science have been under research at our groups for more than a decade now. In this paper, we describe our sensor-driven approaches to workflow recognition without the need for explicit models, and our current aim is to apply this knowledge to enable context-aware surgical assistance systems, such as a unified surgical display and robotic assistance systems. The methods we evaluated over time include dynamic time warping, hidden Markov models, random forests, and recently deep neural networks, specifically convolutional neural networks.

  4. Interfaces for Modular Surgical Planning and Assistance Systems

    OpenAIRE

    Gessat, Michael

    2010-01-01

    Modern surgery of the 21st century relies in many aspects on computers or, in a wider sense, digital data processing. Department administration, OR scheduling, billing, and - with increasing pervasion - patient data management are performed with the aid of so called Surgical Information Systems (SIS) or, more general, Hospital Information Systems (HIS). Computer Assisted Surgery (CAS) summarizes techniques which assist a surgeon in the preparation and conduction of surgical interventions...

  5. A projective surgical navigation system for cancer resection

    Science.gov (United States)

    Gan, Qi; Shao, Pengfei; Wang, Dong; Ye, Jian; Zhang, Zeshu; Wang, Xinrui; Xu, Ronald

    2016-03-01

    Near infrared (NIR) fluorescence imaging technique can provide precise and real-time information about tumor location during a cancer resection surgery. However, many intraoperative fluorescence imaging systems are based on wearable devices or stand-alone displays, leading to distraction of the surgeons and suboptimal outcome. To overcome these limitations, we design a projective fluorescence imaging system for surgical navigation. The system consists of a LED excitation light source, a monochromatic CCD camera, a host computer, a mini projector and a CMOS camera. A software program is written by C++ to call OpenCV functions for calibrating and correcting fluorescence images captured by the CCD camera upon excitation illumination of the LED source. The images are projected back to the surgical field by the mini projector. Imaging performance of this projective navigation system is characterized in a tumor simulating phantom. Image-guided surgical resection is demonstrated in an ex-vivo chicken tissue model. In all the experiments, the projected images by the projector match well with the locations of fluorescence emission. Our experimental results indicate that the proposed projective navigation system can be a powerful tool for pre-operative surgical planning, intraoperative surgical guidance, and postoperative assessment of surgical outcome. We have integrated the optoelectronic elements into a compact and miniaturized system in preparation for further clinical validation.

  6. Surgical drill system and surgical drill bit to be used therein

    NARCIS (Netherlands)

    Margallo Balbas, E.; Wieringa, P.A.; French, P.J.; Lee, R.A.; Breedveld, P.

    2007-01-01

    Surgical drill system comprising a mechanical drill bit and means for imaging the vicinity of the drill bit tip, said means comprising: at least one optical fiber having a distal end and a proximal end, said distal end being located adjacent said drill bit tip, an optical processing unit, said

  7. Independent Navigation System for a Surgical Colonoscope

    Directory of Open Access Journals (Sweden)

    Lilia A. Ochoa-Luna

    2013-08-01

    Full Text Available This paper provides a novel algorithm to attain the independent navigation of a colonoscopy surgical endoscope. First, it introduces a brief description of this issue through the scientist advance for medical robotics. It then makes a quickly count of the existent methods and at the end it provides the basis in order to propose a new alternative solution with help from vision-guidance. That means that images will be processed and interpreted with the purpose of maintaining the endoscope always at the intestine center. All this considered will help us to reduce colonoscopy surgeries consequences and the most important advantage of this new method proposed is that surgeons will accomplish their work easier and more efficiently.

  8. Ultrasound pregnancy

    Science.gov (United States)

    Pregnancy sonogram; Obstetric ultrasonography; Obstetric sonogram; Ultrasound - pregnancy; IUGR - ultrasound; Intrauterine growth - ultrasound; Polyhydramnios - ultrasound; Oligohydramnios - ultrasound; ...

  9. Optical surgical navigation system causes pulse oximeter malfunction.

    Science.gov (United States)

    Satoh, Masaaki; Hara, Tetsuhito; Tamai, Kenji; Shiba, Juntaro; Hotta, Kunihisa; Takeuchi, Mamoru; Watanabe, Eiju

    2015-01-01

    An optical surgical navigation system is used as a navigator to facilitate surgical approaches, and pulse oximeters provide valuable information for anesthetic management. However, saw-tooth waves on the monitor of a pulse oximeter and the inability of the pulse oximeter to accurately record the saturation of a percutaneous artery were observed when a surgeon started an optical navigation system. The current case is thought to be the first report of this navigation system interfering with pulse oximetry. The causes of pulse jamming and how to manage an optical navigation system are discussed.

  10. Surgical bedside master console for neurosurgical robotic system.

    Science.gov (United States)

    Arata, Jumpei; Kenmotsu, Hajime; Takagi, Motoki; Hori, Tatsuya; Miyagi, Takahiro; Fujimoto, Hideo; Kajita, Yasukazu; Hayashi, Yuichiro; Chinzei, Kiyoyuki; Hashizume, Makoto

    2013-01-01

    We are currently developing a neurosurgical robotic system that facilitates access to residual tumors and improves brain tumor removal surgical outcomes. The system combines conventional and robotic surgery allowing for a quick conversion between the procedures. This concept requires a new master console that can be positioned at the surgical bedside and be sterilized. The master console was developed using new technologies, such as a parallel mechanism and pneumatic sensors. The parallel mechanism is a purely passive 5-DOF (degrees of freedom) joystick based on the author's haptic research. The parallel mechanism enables motion input of conventional brain tumor removal surgery with a compact, intuitive interface that can be used in a conventional surgical environment. In addition, the pneumatic sensors implemented on the mechanism provide an intuitive interface and electrically isolate the tool parts from the mechanism so they can be easily sterilized. The 5-DOF parallel mechanism is compact (17 cm width, 19cm depth, and 15cm height), provides a 505,050 mm and 90° workspace and is highly backdrivable (0.27N of resistance force representing the surgical motion). The evaluation tests revealed that the pneumatic sensors can properly measure the suction strength, grasping force, and hand contact. In addition, an installability test showed that the master console can be used in a conventional surgical environment. The proposed master console design was shown to be feasible for operative neurosurgery based on comprehensive testing. This master console is currently being tested for master-slave control with a surgical robotic system.

  11. Five-dimensional ultrasound system for soft tissue visualization.

    Science.gov (United States)

    Deshmukh, Nishikant P; Caban, Jesus J; Taylor, Russell H; Hager, Gregory D; Boctor, Emad M

    2015-12-01

    A five-dimensional ultrasound (US) system is proposed as a real-time pipeline involving fusion of 3D B-mode data with the 3D ultrasound elastography (USE) data as well as visualization of these fused data and a real-time update capability over time for each consecutive scan. 3D B-mode data assist in visualizing the anatomy of the target organ, and 3D elastography data adds strain information. We investigate the feasibility of such a system and show that an end-to-end real-time system, from acquisition to visualization, can be developed. We present a system that consists of (a) a real-time 3D elastography algorithm based on a normalized cross-correlation (NCC) computation on a GPU; (b) real-time 3D B-mode acquisition and network transfer; (c) scan conversion of 3D elastography and B-mode volumes (if acquired by 4D wobbler probe); and (d) visualization software that fuses, visualizes, and updates 3D B-mode and 3D elastography data in real time. We achieved a speed improvement of 4.45-fold for the threaded version of the NCC-based 3D USE versus the non-threaded version. The maximum speed was 79 volumes/s for 3D scan conversion. In a phantom, we validated the dimensions of a 2.2-cm-diameter sphere scan-converted to B-mode volume. Also, we validated the 5D US system visualization transfer function and detected 1- and 2-cm spherical objects (phantom lesion). Finally, we applied the system to a phantom consisting of three lesions to delineate the lesions from the surrounding background regions of the phantom. A 5D US system is achievable with real-time performance. We can distinguish between hard and soft areas in a phantom using the transfer functions.

  12. Virtual Reality Simulator Systems in Robotic Surgical Training.

    Science.gov (United States)

    Mangano, Alberto; Gheza, Federico; Giulianotti, Pier Cristoforo

    2018-06-01

    The number of robotic surgical procedures has been increasing worldwide. It is important to maximize the cost-effectiveness of robotic surgical training and safely reduce the time needed for trainees to reach proficiency. The use of preliminary lab training in robotic skills is a good strategy for the rapid acquisition of further, standardized robotic skills. Such training can be done either by using a simulator or by exercises in a dry or wet lab. While the use of an actual robotic surgical system for training may be problematic (high cost, lack of availability), virtual reality (VR) simulators can overcome many of these obstacles. However, there is still a lack of standardization. Although VR training systems have improved, they cannot yet replace experience in a wet lab. In particular, simulated scenarios are not yet close enough to a real operative experience. Indeed, there is a difference between technical skills (i.e., mechanical ability to perform a simulated task) and surgical competence (i.e., ability to perform a real surgical operation). Thus, while a VR simulator can replace a dry lab, it cannot yet replace training in a wet lab or operative training in actual patients. However, in the near future, it is expected that VR surgical simulators will be able to provide total reality simulation and replace training in a wet lab. More research is needed to produce more wide-ranging, trans-specialty robotic curricula.

  13. Experimental ultrasound system for real-time synthetic imaging

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Holm, Ole; Jensen, Lars Joost

    1999-01-01

    Digital signal processing is being employed more and more in modern ultrasound scanners. This has made it possible to do dynamic receive focusing for each sample and implement other advanced imaging methods. The processing, however, has to be very fast and cost-effective at the same time. Dedicated...... for synthetic aperture imaging, 2D and 3D B-mode and velocity imaging. The system can be used with 128 element transducers and can excite 128 channels and receive and sample data from 64 channels simultaneously at 40 MHz with 12 bits precision. Data can be processed in real time using the system's 80 signal...... chips are used in order to do real time processing. This often makes it difficult to implement radically different imaging strategies on one platform and makes the scanners less accessible for research purposes. Here flexibility is the prime concern, and the storage of data from all transducer elements...

  14. Towards 3D ultrasound image based soft tissue tracking: a transrectal ultrasound prostate image alignment system.

    Science.gov (United States)

    Baumann, Michael; Mozer, Pierre; Daanen, Vincent; Troccaz, Jocelyne

    2007-01-01

    The emergence of real-time 3D ultrasound (US) makes it possible to consider image-based tracking of subcutaneous soft tissue targets for computer guided diagnosis and therapy. We propose a 3D transrectal US based tracking system for precise prostate biopsy sample localisation. The aim is to improve sample distribution, to enable targeting of unsampled regions for repeated biopsies, and to make post-interventional quality controls possible. Since the patient is not immobilized, since the prostate is mobile and due to the fact that probe movements are only constrained by the rectum during biopsy acquisition, the tracking system must be able to estimate rigid transformations that are beyond the capture range of common image similarity measures. We propose a fast and robust multi-resolution attribute-vector registration approach that combines global and local optimization methods to solve this problem. Global optimization is performed on a probe movement model that reduces the dimensionality of the search space and thus renders optimization efficient. The method was tested on 237 prostate volumes acquired from 14 different patients for 3D to 3D and 3D to orthogonal 2D slices registration. The 3D-3D version of the algorithm converged correctly in 96.7% of all cases in 6.5s with an accuracy of 1.41mm (r.m.s.) and 3.84mm (max). The 3D to slices method yielded a success rate of 88.9% in 2.3s with an accuracy of 1.37mm (r.m.s.) and 4.3mm (max).

  15. Adaptive lesion formation using dual mode ultrasound array system

    Science.gov (United States)

    Liu, Dalong; Casper, Andrew; Haritonova, Alyona; Ebbini, Emad S.

    2017-03-01

    We present the results from an ultrasound-guided focused ultrasound platform designed to perform real-time monitoring and control of lesion formation. Real-time signal processing of echogenicity changes during lesion formation allows for identification of signature events indicative of tissue damage. The detection of these events triggers the cessation or the reduction of the exposure (intensity and/or time) to prevent overexposure. A dual mode ultrasound array (DMUA) is used for forming single- and multiple-focus patterns in a variety of tissues. The DMUA approach allows for inherent registration between the therapeutic and imaging coordinate systems providing instantaneous, spatially-accurate feedback on lesion formation dynamics. The beamformed RF data has been shown to have high sensitivity and specificity to tissue changes during lesion formation, including in vivo. In particular, the beamformed echo data from the DMUA is very sensitive to cavitation activity in response to HIFU in a variety of modes, e.g. boiling cavitation. This form of feedback is characterized by sudden increase in echogenicity that could occur within milliseconds of the application of HIFU (see http://youtu.be/No2wh-ceTLs for an example). The real-time beamforming and signal processing allowing the adaptive control of lesion formation is enabled by a high performance GPU platform (response time within 10 msec). We present results from a series of experiments in bovine cardiac tissue demonstrating the robustness and increased speed of volumetric lesion formation for a range of clinically-relevant exposures. Gross histology demonstrate clearly that adaptive lesion formation results in tissue damage consistent with the size of the focal spot and the raster scan in 3 dimensions. In contrast, uncontrolled volumetric lesions exhibit significant pre-focal buildup due to excessive exposure from multiple full-exposure HIFU shots. Stopping or reducing the HIFU exposure upon the detection of such an

  16. Implementation of a versatile research data acquisition system using a commercially available medical ultrasound scanner

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Nikolov, Svetoslav Ivanov; Pedersen, Mads Møller

    2012-01-01

    to the clinic. The system consists of a standard PC equipped with a camera link and an ultrasound scanner equipped with a research interface. The ultrasound scanner is an easy-to-use imaging device that is capable of generating high-quality images. In addition to supporting the acquisition of multiple data...

  17. Ultrasound-guided supra-acetabular pin placement in pelvic external fixation: description of a surgical technique and results.

    Science.gov (United States)

    Chana-Rodríguez, Francisco; Cuervas-Mons, Manuel; Rojo-Manaute, José; Mora, Félix; Arnal, Juan; Vaquero-Martín, Javier

    2017-11-01

    Pelvic fracture in trauma patients can lead to hemodynamic instability. External fixation is a treatment capable of stabilizing these injuries in the context of damage control surgery. Supra-acetabular pin offers the greater biomechanical stability but requires the use of intraoperative fluoroscopy. The aim of this study was to analyze our results for an ultrasound-guided supra-acetabular pinning. Cross-sectional study with cadaveric specimens. Ultrasound-guided pin placement assessed by fluoroscopy and dissection. Fourteen ultrasound-guided supra-acetabular pins were placed in seven cadaveric specimens. Excellent placement in all cases, evaluated with radiological control. Good qualitative bone fixation after dissection. One femoral cutaneous nerve was not found during anatomic dissection and was assumed injured. Ultrasound-guided supra-acetabular pin placement is a feasible and effective technique. Our study indicates that pin placement without intraoperative fluoroscopy is feasible without compromising the reliability of its placement. © 2017 Elsevier Ltd. All rights reserved.

  18. The Presto 1000: A novel automated transcranial Doppler ultrasound system.

    Science.gov (United States)

    Han, Seunggu J; Rutledge, William Caleb; Englot, Dario J; Winkler, Ethan A; Browne, Janet L; Pflugrath, Lauren; Cronsier, David; Abla, Adib A; Kliot, Michel; Lawton, Michael T

    2015-11-01

    We examined the reliability and ease of use of a novel automated transcranial Doppler (TCD) system in comparison to a conventional TCD system. TCD ultrasound allows non-invasive monitoring of cerebral blood flow, and can predict arterial vasospasm after a subarachnoid hemorrhage (SAH). The Presto 1000 TCD system (PhysioSonics, Bellevue, WA, USA) is designed for monitoring flow through the M1 segment of the middle cerebral artery (MCA) via temporal windows. The Presto 1000 system was tested across multiple preclinical and clinical settings in parallel with a control predicate TCD system. In a phantom flow generating device, both the Presto 1000 and Spencer system (Spencer Technologies, Redmond, WA, USA) were able to detect velocities with high accuracy. In nine volunteer patients, the Presto system was able to locate the MCA in 14 out of 18 temporal windows, in an average of 12.5s. In the SAH cohort of five patients with a total of 25 paired measurements, the mean absolute difference in flow velocities of the M1 segment, as measured by the two systems, was 17.5 cm/s. These data suggest that the Presto system offers an automated TCD that can reliably localize and detect flow of the MCA, with relative ease of use. The system carries the additional benefit of requiring minimal training for the operator, and can be used by many providers across multiple bedside settings. The mean velocities that were generated warrant further validation across an extended group of patients, and the predictive value for vasospasm should be checked against the current standard of angiography. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. A single FPGA-based portable ultrasound imaging system for point-of-care applications.

    Science.gov (United States)

    Kim, Gi-Duck; Yoon, Changhan; Kye, Sang-Bum; Lee, Youngbae; Kang, Jeeun; Yoo, Yangmo; Song, Tai-kyong

    2012-07-01

    We present a cost-effective portable ultrasound system based on a single field-programmable gate array (FPGA) for point-of-care applications. In the portable ultrasound system developed, all the ultrasound signal and image processing modules, including an effective 32-channel receive beamformer with pseudo-dynamic focusing, are embedded in an FPGA chip. For overall system control, a mobile processor running Linux at 667 MHz is used. The scan-converted ultrasound image data from the FPGA are directly transferred to the system controller via external direct memory access without a video processing unit. The potable ultrasound system developed can provide real-time B-mode imaging with a maximum frame rate of 30, and it has a battery life of approximately 1.5 h. These results indicate that the single FPGA-based portable ultrasound system developed is able to meet the processing requirements in medical ultrasound imaging while providing improved flexibility for adapting to emerging POC applications.

  20. A GPU Accelerated Spring Mass System for Surgical Simulation

    DEFF Research Database (Denmark)

    Mosegaard, Jesper; Sørensen, Thomas Sangild

    2005-01-01

    There is a growing demand for surgical simulators to dofast and precise calculations of tissue deformation to simulateincreasingly complex morphology in real-time. Unfortunately, evenfast spring-mass based systems have slow convergence rates for largemodels. This paper presents a method to accele...... to accelerate computation of aspring-mass system in order to simulate a complex organ such as theheart. This acceleration is achieved by taking advantage of moderngraphics processing units (GPU)....

  1. Robot-assisted ultrasound imaging: overview and development of a parallel telerobotic system.

    Science.gov (United States)

    Monfaredi, Reza; Wilson, Emmanuel; Azizi Koutenaei, Bamshad; Labrecque, Brendan; Leroy, Kristen; Goldie, James; Louis, Eric; Swerdlow, Daniel; Cleary, Kevin

    2015-02-01

    Ultrasound imaging is frequently used in medicine. The quality of ultrasound images is often dependent on the skill of the sonographer. Several researchers have proposed robotic systems to aid in ultrasound image acquisition. In this paper we first provide a short overview of robot-assisted ultrasound imaging (US). We categorize robot-assisted US imaging systems into three approaches: autonomous US imaging, teleoperated US imaging, and human-robot cooperation. For each approach several systems are introduced and briefly discussed. We then describe a compact six degree of freedom parallel mechanism telerobotic system for ultrasound imaging developed by our research team. The long-term goal of this work is to enable remote ultrasound scanning through teleoperation. This parallel mechanism allows for both translation and rotation of an ultrasound probe mounted on the top plate along with force control. Our experimental results confirmed good mechanical system performance with a positioning error of < 1 mm. Phantom experiments by a radiologist showed promising results with good image quality.

  2. The Effects of Ultrasound on Biological Systems: Site

    Science.gov (United States)

    El-Karmi, Anan M.

    Earlier studies (Dinno et al., Ultrasound Med. Biol. 15:461 -470; 1989) demonstrated that ultrasound at therapeutic intensities causes large increases in total conductance (G_{rm t}) of frog skin. These changes were attributed to non-thermal mechanisms, primarily, cavitation. In this study, the site(s) and mechanism(s) of action of ultrasound for the increase in G_{rm t} were examined. The reversible changes in G_{rm t } and sodium current were monitored in real time as a function of ultrasound exposure. Amiloride, a sodium channel blocker, was used to differentiate between cellular (G_{rm c}) and paracellular (G_{rm s}) pathways in the presence and absence of ultrasound. No significant changes were detected in G_ {rm c}. However, changes in G _{rm s} were significant. These results demonstrate that most of the increase in G _{rm t} due to ultrasound is taking place in the paracellular pathways. Sodium channels were not significantly affected by ultrasound. Thus, the changes in G_{rm c} are not specific. The effects of ultrasound were examined in the presence of radical scavengers and antioxidants. The increase in G_{rm t} due to ultrasound was significantly minimized in the presence of cystamine, cysteamine, and sodium ascorbate. This demonstrates that free radicals and other reactive species generated by cavitation are causing the increase in G_ {rm t}, possibly by acting from inside the cells. Radical scavengers and antioxidants are providing protection from oxidative damage but are not involved in the recovery of G_{ rm t} towards steady state values after sonication. The role of Ca^{2+} in the effects of ultrasound was examined since many of the cellular reactions involved in tissue recovery are dependent on the intracellular availability of free Ca^{2+}. The percentage increase in G_{rm t} in the presence of Ca^{2+} was larger than in its absence (140% vs. 27%). The time constant for G_{rm t} to return to steady state was longer in calcium-free solutions (122

  3. System Architecture of an Experimental Synthetic Aperture Real-Time Ultrasound System

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Hansen, Martin; Tomov, Borislav Gueorguiev

    2007-01-01

    is done using a parametric beam former. Code synthesized for a Xilinx V4FX100 speed grade 11 FPGA can operate at a maximum clock frequency of 167.8 MHz producing 1 billion I and Q samples/second sufficient for real time SA imaging. The system is currently in production, and all boards have been laid out......Synthetic Aperture (SA) ultrasound imaging has many advantages in terms of flexibility and accuracy. One of the major drawbacks is, however, that no system exists, which can implement SA imaging in real time due to the very high number of calculations amounting to roughly 1 billion complex focused...... samples per second per receive channel. Real time imaging is a key aspect in ultrasound, and to truly demonstrate the many advantages of SA imaging, a system usable in the clinic should be made. The paper describes a system capable of real time SA B-mode and vector flow imaging. The Synthetic Aperture...

  4. Multifunctional pulse generator for high-intensity focused ultrasound system

    Science.gov (United States)

    Tamano, Satoshi; Yoshizawa, Shin; Umemura, Shin-Ichiro

    2017-07-01

    High-intensity focused ultrasound (HIFU) can achieve high spatial resolution for the treatment of diseases. A major technical challenge in implementing a HIFU therapeutic system is to generate high-voltage high-current signals for effectively exciting a multichannel HIFU transducer at high efficiencies. In this paper, we present the development of a multifunctional multichannel generator/driver. The generator can produce a long burst as well as an extremely high-voltage short pulse of pseudosinusoidal waves (trigger HIFU) and second-harmonic superimposed waves for HIFU transmission. The transmission timing, waveform, and frequency can be controlled using a field-programmable gate array (FPGA) via a universal serial bus (USB) microcontroller. The hardware is implemented in a compact printed circuit board. The test results of trigger HIFU reveal that the power consumption and the temperature rise of metal-oxide semiconductor field-effect transistors were reduced by 19.9% and 38.2 °C, respectively, from the previous design. The highly flexible performance of the novel generator/driver is demonstrated in the generation of second-harmonic superimposed waves, which is useful for cavitation-enhanced HIFU treatment, although the previous design exhibited difficulty in generating it.

  5. Low-cost Volumetric Ultrasound by Augmentation of 2D Systems: Design and Prototype.

    Science.gov (United States)

    Herickhoff, Carl D; Morgan, Matthew R; Broder, Joshua S; Dahl, Jeremy J

    2018-01-01

    Conventional two-dimensional (2D) ultrasound imaging is a powerful diagnostic tool in the hands of an experienced user, yet 2D ultrasound remains clinically underutilized and inherently incomplete, with output being very operator dependent. Volumetric ultrasound systems can more fully capture a three-dimensional (3D) region of interest, but current 3D systems require specialized transducers, are prohibitively expensive for many clinical departments, and do not register image orientation with respect to the patient; these systems are designed to provide improved workflow rather than operator independence. This work investigates whether it is possible to add volumetric 3D imaging capability to existing 2D ultrasound systems at minimal cost, providing a practical means of reducing operator dependence in ultrasound. In this paper, we present a low-cost method to make 2D ultrasound systems capable of quality volumetric image acquisition: we present the general system design and image acquisition method, including the use of a probe-mounted orientation sensor, a simple probe fixture prototype, and an offline volume reconstruction technique. We demonstrate initial results of the method, implemented using a Verasonics Vantage research scanner.

  6. Development of a High Intensity Focused Ultrasound (HIFU) Hydrophone System

    International Nuclear Information System (INIS)

    Schafer, Mark E.; Gessert, James

    2009-01-01

    The growing clinical use of High Intensity Focused Ultrasound (HIFU) has driven a need for reliable, reproducible measurements of HIFU acoustic fields. We have previously presented data on a reflective scatterer approach, incorporating several novel features for improved bandwidth, reliability, and reproducibility [Proc. 2005 IEEE Ultrasonics Symposium, 1739-1742]. We now report on several design improvements which have increase the signal to noise ratio of the system, and potentially reduced the cost of implementation. For the scattering element, we now use an artificial sapphire material to provide a more uniform radiating surface. The receiver is a segmented, truncated spherical structure with a 10 cm radius; the scattering element is positioned at the center of the sphere. The receiver is made from 25 micron thick, biaxially stretched PVDF, with a Pt-Au electrode on the front surface. In the new design, a specialized backing material provides the stiffness required to maintain structural stability, while at the same time providing both electrical shielding and ultrasonic absorption. Compared with the previous version, the new receiver design has improved the noise performance by 8-12 dB; the new scattering sphere has reduced the scattering loss by another 14 dB, producing an effective sensitivity of -298 dB re 1 microVolt/Pa. The design trade-off still involves receiver sensitivity with effective spot size, and signal distortion from the scatter structure. However, the reduced cost and improved repeatability of the new scatter approach makes the overall design more robust for routine waveform measurements of HIFU systems.

  7. Critical roles of orthopaedic surgeon leadership in healthcare systems to improve orthopaedic surgical patient safety.

    Science.gov (United States)

    Kuo, Calvin C; Robb, William J

    2013-06-01

    The prevention of medical and surgical harm remains an important public health problem despite increased awareness and implementation of safety programs. Successful introduction and maintenance of surgical safety programs require both surgeon leadership and collaborative surgeon-hospital alignment. Documentation of success of such surgical safety programs in orthopaedic practice is limited. We describe the scope of orthopaedic surgical patient safety issues, define critical elements of orthopaedic surgical safety, and outline leadership roles for orthopaedic surgeons needed to establish and sustain a culture of safety in contemporary healthcare systems. We identified the most common causes of preventable surgical harm based on adverse and sentinel surgical events reported to The Joint Commission. A comprehensive literature review through a MEDLINE(®) database search (January 1982 through April 2012) to identify pertinent orthopaedic surgical safety articles found 14 articles. Where gaps in orthopaedic literature were identified, the review was supplemented by 22 nonorthopaedic surgical references. Our final review included 36 articles. Six important surgical safety program elements needed to eliminate preventable surgical harm were identified: (1) effective surgical team communication, (2) proper informed consent, (3) implementation and regular use of surgical checklists, (4) proper surgical site/procedure identification, (5) reduction of surgical team distractions, and (6) routine surgical data collection and analysis to improve the safety and quality of surgical patient care. Successful surgical safety programs require a culture of safety supported by all six key surgical safety program elements, active surgeon champions, and collaborative hospital and/or administrative support designed to enhance surgical safety and improve surgical patient outcomes. Further research measuring improvements from such surgical safety systems in orthopaedic care is needed.

  8. Performance Evaluation of a Synthetic Aperture Real-Time Ultrasound System

    DEFF Research Database (Denmark)

    Stuart, Matthias Bo; Tomov, Borislav Gueorguiev; Jensen, Jørgen Arendt

    2011-01-01

    This paper evaluates the signal-to-noise ratio, the time stability, and the phase difference of the sampling in the experimental ultrasound scanner SARUS: A synthetic aperture, real-time ultrasound system. SARUS has 1024 independent transmit and receive channels and is capable of handling 2D probes...... arrays (FPGAs) making it very flexible and allowing implementation of other real-time ultrasound processing methods in the future. For conventional B-mode imaging, a penetration depth around 7 cm for a 7 MHz transducer is obtained (signal-tonoise ratio of 0 dB), which is comparable to commercial...... for 3D ultrasound imaging. It samples at 12 bits per sample and has a sampling rate of 70 MHz with the possibility of decimating the sampling frequency at the input. SARUS is capable of advanced real-time computations such as synthetic aperture imaging. The system is built using fieldprogrammable gate...

  9. Dissimilar trend of nonlinearity in ultrasound transducers and systems at resonance and non-resonance frequencies

    DEFF Research Database (Denmark)

    Ghasemi, Negareh; Zare, Firuz; Davari, Pooya

    2017-01-01

    Several factors can affect performance of an ultrasound system such as quality of excitation signal and ultrasound transducer behaviour. Nonlinearity of piezoelectric ultrasound transducers is a key determinant in designing a proper driving power supply. Although, the nonlinearity of piezoelectric...... was excited at different frequencies. Different excitation signals were generated using a linear power amplifier and a multilevel converter within a range of 30–200 V. Empirical relation was developed to express the resistance of the piezoelectric transducer as a nonlinear function of both excitation voltage...... and resonance frequency. The impedance measurements revealed that at higher voltage ranges, the piezoelectric transducer can be easily saturated. Also, it was shown that for the developed ultrasound system composed of two transducers (one transmitter and one receiver), the output voltage measured across...

  10. PLUS: open-source toolkit for ultrasound-guided intervention systems.

    Science.gov (United States)

    Lasso, Andras; Heffter, Tamas; Rankin, Adam; Pinter, Csaba; Ungi, Tamas; Fichtinger, Gabor

    2014-10-01

    A variety of advanced image analysis methods have been under the development for ultrasound-guided interventions. Unfortunately, the transition from an image analysis algorithm to clinical feasibility trials as part of an intervention system requires integration of many components, such as imaging and tracking devices, data processing algorithms, and visualization software. The objective of our paper is to provide a freely available open-source software platform-PLUS: Public software Library for Ultrasound-to facilitate rapid prototyping of ultrasound-guided intervention systems for translational clinical research. PLUS provides a variety of methods for interventional tool pose and ultrasound image acquisition from a wide range of tracking and imaging devices, spatial and temporal calibration, volume reconstruction, simulated image generation, and recording and live streaming of the acquired data. This paper introduces PLUS, explains its functionality and architecture, and presents typical uses and performance in ultrasound-guided intervention systems. PLUS fulfills the essential requirements for the development of ultrasound-guided intervention systems and it aspires to become a widely used translational research prototyping platform. PLUS is freely available as open source software under BSD license and can be downloaded from http://www.plustoolkit.org.

  11. Prototype volumetric ultrasound tomography image guidance system for prone stereotactic partial breast irradiation: proof-of-concept

    Science.gov (United States)

    Chiu, Tsuicheng D.; Parsons, David; Zhang, Yue; Hrycushko, Brian; Zhao, Bo; Chopra, Rajiv; Kim, Nathan; Spangler, Ann; Rahimi, Asal; Timmerman, Robert; Jiang, Steve B.; Lu, Weiguo; Gu, Xuejun

    2018-03-01

    Accurate dose delivery in stereotactic partial breast irradiation (S-PBI) is challenging because of the target position uncertainty caused by breast deformation, the target volume changes caused by lumpectomy cavity shrinkage, and the target delineation uncertainty on simulation computed tomography (CT) images caused by poor soft tissue contrast. We have developed a volumetric ultrasound tomography (UST) image guidance system for prone position S-PBI. The system is composed of a novel 3D printed rotation water tank, a patient-specific resin breast immobilization cup, and a 1D array ultrasound transducer. Coronal 2D US images were acquired in 5° increments over a 360° range, and planes were acquired every 2 mm in elevation. A super-compounding technique was used to reconstruct the image volume. The image quality of UST was evaluated with a BB-1 breast phantom and BioZorb surgical marker, and the results revealed that UST offered better soft tissue contrast than CT and similar image quality to MR. In the evaluated plane, the size and location of five embedded objects were measured and compared to MR, which is considered as the ground truth. Objects’ diameters and the distances between objects in UST differ by approximately 1 to 2 mm from those in MR, which showed that UST offers the image quality required for S-PBI. In future work we will develop a robotic system that will be ultimately implemented in the clinic.

  12. Postoperative Surgical Site Infections: Understanding the Discordance Between Surveillance Systems.

    Science.gov (United States)

    Ali-Mucheru, Mariam N; Seville, Maria T; Miller, Vickie; Sampathkumar, Priya; Etzioni, David A

    2018-04-18

    To characterize agreement in the ascertainment of surgical site infections (SSIs) between the National Surgical Quality Improvement Program (NSQIP), National Healthcare Safety Network (NHSN), and administrative data. The NSQIP, NHSN, and administrative data are the primary systems used to monitor and report SSIs for the purpose of quality control and benchmarking of hospitals and surgeons. These systems have different methods for identifying SSIs. We queried the NHSN, NSQIP, and administrative data systems for patients who had an operation at 1 of 4 hospitals within a single health system between January 2013 and September 2015. The detection of an SSI during a postoperative hospitalization was the outcome of analysis. Any SSI detected by one (or more) of these systems was analyzed by 2 reviewers to determine the presence of discrete elements of documentation constituting evidence of SSI. Concordance between the 3 systems (NHSN, NSQIP, and administrative data) was analyzed using Cohen's kappa. After application of appropriate exclusion criteria, a cohort of 9447 inpatient operations was analyzed. In total, 130 SSIs were detected by 1 or more of the 3 systems, with reported SSI rates of 0.5% (NHSN), 0.7% (administrative data), and 1.0% (NSQIP). Of these 130 SSIs, only 17 SSIs were reported by all 3 systems. The concordance between these 3 systems was moderate (kappa values NSQIP-NHSN = 0.50 [0.40-0.60], administrative-NHSN = 0.36 [0.24-0.47], and administrative-NSQIP = 0.47 [0.38-0.57]). Chart review found that reasons for discordance were related to issues of different criteria as well as inaccuracies. There is significant discordance in the determination of SSIs reported by the NHSN, NSQIP, and administrative data. The differences and limitations of each of these systems have to be recognized, especially when using these data for quality reports and pay for performance.

  13. A multicenter prospective study of surgical audit systems.

    Science.gov (United States)

    Haga, Yoshio; Ikejiri, Koji; Wada, Yasuo; Takahashi, Tadateru; Ikenaga, Masakazu; Akiyama, Noriyoshi; Koike, Shoichiro; Koseki, Masato; Saitoh, Toshihiro

    2011-01-01

    This study was undertaken to evaluate a modified form of Estimation of Physiologic Ability and Surgical Stress (E-PASS) for surgical audit comparing with other existing models. Although several scoring systems have been devised for surgical audit, no nation-wide survey has been performed yet. We modified our previous E-PASS surgical audit system by computing the weights of 41 procedures, using data from 4925 patients who underwent elective digestive surgery, designated it as mE-PASS. Subsequently, a prospective cohort study was conducted in 43 national hospitals in Japan from April 1, 2005, to April 8, 2007. Variables for the E-PASS and American Society of Anesthesiologists (ASA) status-based model were collected for 5272 surgically treated patients. Of the 5272 patients, we also collected data for the Portsmouth modification of Physiologic and Operative Severity Score for the enUmeration of Mortality and morbidity (P-POSSUM) in 3128 patients. The area under the receiver operative characteristic curve (AUC) was used to evaluate discrimination performance to detect in-hospital mortality. The ratio of observed to estimated in-hospital mortality rates (OE ratio) was defined as a measure of quality. The numbers of variables required were 10 for E-PASS, 7 for mE-PASS, 20 for P-POSSUM, and 4 for the ASA status-based model. The AUC (95% confidence interval) values were 0.86 (0.79-0.93) for E-PASS, 0.86 (0.79-0.92) for mE-PASS, 0.81 (0.75-0.88) for P-POSSUM, and 0.73 (0.63-0.83) for the ASA status-based model. The OE ratios for mE-PASS among large-volume hospitals significantly correlated with those for E-PASS (R = 0.93, N = 9, P = 0.00026), P-POSSUM (R = 0.96, N = 6, P = 0.0021), and ASA status-based model (R = 0.83, N = 9, P = 0.0051). Because of its features of easy use, accuracy, and generalizability, mE-PASS is a candidate for a nation-wide survey.

  14. Musculoskeletal ultrasound on the hand and wrist in systemic sclerosis

    Directory of Open Access Journals (Sweden)

    Rasha M Fawzy

    2016-01-01

    Conclusion Ultrasound was more accurate than clinical examination and conventional radiography in the detection of subclinical synovitis, tenosynovitis, and the underlying fibrotic changes of tendon friction rub. In SSc patients, on using MSUS, articular involvement was found to be less frequent compared with that in RA patients, with specific appearance of sclerosing tenosynovitis in SSc patients.

  15. Development of a precision multimodal surgical navigation system for lung robotic segmentectomy.

    Science.gov (United States)

    Baste, Jean Marc; Soldea, Valentin; Lachkar, Samy; Rinieri, Philippe; Sarsam, Mathieu; Bottet, Benjamin; Peillon, Christophe

    2018-04-01

    Minimally invasive sublobar anatomical resection is becoming more and more popular to manage early lung lesions. Robotic-assisted thoracic surgery (RATS) is unique in comparison with other minimally invasive techniques. Indeed, RATS is able to better integrate multiple streams of information including advanced imaging techniques, in an immersive experience at the level of the robotic console. Our aim was to describe three-dimensional (3D) imaging throughout the surgical procedure from preoperative planning to intraoperative assistance and complementary investigations such as radial endobronchial ultrasound (R-EBUS) and virtual bronchoscopy for pleural dye marking. All cases were operated using the DaVinci System TM . Modelisation was provided by Visible Patient™ (Strasbourg, France). Image integration in the operative field was achieved using the Tile Pro multi display input of the DaVinci console. Our experience was based on 114 robotic segmentectomies performed between January 2012 and October 2017. The clinical value of 3D imaging integration was evaluated in 2014 in a pilot study. Progressively, we have reached the conclusion that the use of such an anatomic model improves the safety and reliability of procedures. The multimodal system including 3D imaging has been used in more than 40 patients so far and demonstrated a perfect operative anatomic accuracy. Currently, we are developing an original virtual reality experience by exploring 3D imaging models at the robotic console level. The act of operating is being transformed and the surgeon now oversees a complex system that improves decision making.

  16. Superficial Ultrasound Shear Wave Speed Measurements in Soft and Hard Elasticity Phantoms: Repeatability and Reproducibility Using Two Different Ultrasound Systems

    Science.gov (United States)

    Dillman, Jonathan R.; Chen, Shigao; Davenport, Matthew S.; Zhao, Heng; Urban, Matthew W.; Song, Pengfei; Watcharotone, Kuanwong; Carson, Paul L.

    2014-01-01

    Background There is a paucity of data available regarding the repeatability and reproducibility of superficial shear wave speed (SWS) measurements at imaging depths relevant to the pediatric population. Purpose To assess the repeatability and reproducibility of superficial shear wave speed (SWS) measurements acquired from elasticity phantoms at varying imaging depths using three different imaging methods, two different ultrasound systems, and multiple operators. Methods and Materials Soft and hard elasticity phantoms manufactured by Computerized Imaging Reference Systems, Inc. (Norfolk, VA) were utilized for our investigation. Institution #1 used an Acuson S3000 ultrasound system (Siemens Medical Solutions USA, Inc.) and three different shear wave imaging method/transducer combinations, while institution #2 used an Aixplorer ultrasound system (Supersonic Imagine) and two different transducers. Ten stiffness measurements were acquired from each phantom at three depths (1.0, 2.5, and 4.0 cm) by four operators at each institution. Student’s t-test was used to compare SWS measurements between imaging techniques, while SWS measurement agreement was assessed with two-way random effects single measure intra-class correlation coefficients and coefficients of variation. Mixed model regression analysis determined the effect of predictor variables on SWS measurements. Results For the soft phantom, the average of mean SWS measurements across the various imaging methods and depths was 0.84 ± 0.04 m/s (mean ± standard deviation) for the Acuson S3000 system and 0.90 ± 0.02 m/s for the Aixplorer system (p=0.003). For the hard phantom, the average of mean SWS measurements across the various imaging methods and depths was 2.14 ± 0.08 m/s for the Acuson S3000 system and 2.07 ± 0.03 m/s Aixplorer system (p>0.05). The coefficients of variation were low (0.5–6.8%), and inter-operator agreement was near-perfect (ICCs ≥0.99). Shear wave imaging method and imaging depth

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... frequently used to evaluate the reproductive and urinary systems. Ultrasound is safe, noninvasive and does not use ... and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. ...

  18. Assessment of substantia nigra echogenicity in German and Filipino populations using a portable ultrasound system.

    Science.gov (United States)

    Go, Criscely L; Frenzel, Antonia; Rosales, Raymond L; Lee, Lillian V; Benecke, Reiner; Dressler, Dirk; Walter, Uwe

    2012-02-01

    Transcranial sonography of the substantia nigra for diagnosing premotor stages of Parkinson disease has been attracting increasing interest. Standard reference values defining an abnormal increased echogenic size (hyperechogenicity) of the substantia nigra have been established in several populations using high-end stationary ultrasound systems. It is unknown whether a portable ultrasound system can be appropriately used and how the Filipino population would compare with the well-studied white population. We prospectively studied substantia nigra echogenic sizes and third ventricle widths in 71 healthy adult German participants and 30 age- and sex-matched Filipino participants using both a well-established stationary ultrasound system (in the German cohort) and a recently distributed portable ultrasound system (in both ethnic cohorts). Mean substantia nigra echogenic sizes, cutoff values defining abnormal hyperechogenicity, and intra-rater reliability were similar with both systems and in both ethnic cohorts studied. The Filipino and German participants did not differ with respect to the frequency of insufficient insonation conditions (each 3%) and substantia nigra hyperechogenicity (10% versus 9%; P = .80). However, third ventricle widths were smaller in the Filipino than the German participants (mean ± SD, 1.6 ± 1.1 versus 2.4 ± 1.0 mm; P = .004). The frequency of substantia nigra hyperechogenicity appears to be homogeneous in white and Asian populations. Screening for this feature may well be performed with a present-day portable ultrasound system.

  19. Bedside intravascular ultrasound-guided inferior vena cava filter placement in medical-surgical intensive care critically-ill patients

    Directory of Open Access Journals (Sweden)

    Mohammad A. Abusedera

    2015-09-01

    Conclusions: Bedside IVUS-guided filter placement in medical-surgical critically ill patient in intensive care unit is a feasible, safe and reliable technique for IVC interruption. IVUS may be the most appropriate tool to guide filter insertion in obese patient.

  20. Design, implementation and testing of master slave robotic surgical system

    International Nuclear Information System (INIS)

    Ali, S.A.

    2015-01-01

    The autonomous manipulation of the medical robotics is needed to draw up a complete surgical plan in development. The autonomy of the robot comes from the fact that once the plan is drawn up off-line, it is the servo loops, and only these, that control the actions of the robot online, based on instantaneous control signals and measurements provided by the vision or force sensors. Using only these autonomous techniques in medical and surgical robotics remain relatively limited for two main reasons: Predicting complexity of the gestures, and human Safety. Therefore, Modern research in haptic force feedback in medical robotics is aimed to develop medical robots capable of performing remotely, what a surgeon does by himself. These medical robots are supposed to work exactly in the manner that a surgeon does in daily routine. In this paper the master slave tele-robotic system is designed and implemented with accuracy and stability by using 6DOF (Six Degree of Freedom) haptic force feedback devices. The master slave control strategy, haptic devices integration, application software designing using Visual C++ and experimental setup are considered. Finally, results are presented the stability, accuracy and repeatability of the system. (author)

  1. A highly articulated robotic surgical system for minimally invasive surgery.

    Science.gov (United States)

    Ota, Takeyoshi; Degani, Amir; Schwartzman, David; Zubiate, Brett; McGarvey, Jeremy; Choset, Howie; Zenati, Marco A

    2009-04-01

    We developed a novel, highly articulated robotic surgical system (CardioARM) to enable minimally invasive intrapericardial therapeutic delivery through a subxiphoid approach. We performed preliminary proof of concept studies in a porcine preparation by performing epicardial ablation. CardioARM is a robotic surgical system having an articulated design to provide unlimited but controllable flexibility. The CardioARM consists of serially connected, rigid cyclindrical links housing flexible working ports through which catheter-based tools for therapy and imaging can be advanced. The CardioARM is controlled by a computer-driven, user interface, which is operated outside the operative field. In six experimental subjects, the CardioARM was introduced percutaneously through a subxiphoid access. A commercial 5-French radiofrequency ablation catheter was introduced through the working port, which was then used to guide deployment. In all subjects, regional ("linear") left atrial ablation was successfully achieved without complications. Based on these preliminary studies, we believe that the CardioARM promises to enable deployment of a number of epicardium-based therapies. Improvements in imaging techniques will likely facilitate increasingly complex procedures.

  2. Design, Implementation and Testing of Master Slave Robotic Surgical System

    Directory of Open Access Journals (Sweden)

    Syed Amjad Ali

    2015-01-01

    Full Text Available The autonomous manipulation of the medical robotics is needed to draw up a complete surgical plan in development. The autonomy of the robot comes from the fact that once the plan is drawn up off-line, it is the servo loops, and only these, that control the actions of the robot online, based on instantaneous control signals and measurements provided by the vision or force sensors. Using only these autonomous techniques in medical and surgical robotics remain relatively limited for two main reasons: Predicting complexity of the gestures, and human Safety. Therefore, Modern research in haptic force feedback in medical robotics is aimed to develop medical robots capable of performing remotely, what a surgeon does by himself. These medical robots are supposed to work exactly in the manner that a surgeon does in daily routine. In this paper the master slave tele-robotic system is designed and implemented with accuracy and stability by using 6DOF (Six Degree of Freedom haptic force feedback devices. The master slave control strategy, haptic devices integration, application software designing using Visual C++ and experimental setup are considered. Finally, results are presented the stability, accuracy and repeatability of the system

  3. A Wearable Goggle Navigation System for Dual-Mode Optical and Ultrasound Localization of Suspicious Lesions: Validation Studies Using Tissue-Simulating Phantoms and an Ex Vivo Human Breast Tissue Model.

    Directory of Open Access Journals (Sweden)

    Zeshu Zhang

    Full Text Available Surgical resection remains the primary curative treatment for many early-stage cancers, including breast cancer. The development of intraoperative guidance systems for identifying all sites of disease and improving the likelihood of complete surgical resection is an area of active ongoing research, as this can lead to a decrease in the need of subsequent additional surgical procedures. We develop a wearable goggle navigation system for dual-mode optical and ultrasound imaging of suspicious lesions. The system consists of a light source module, a monochromatic CCD camera, an ultrasound system, a Google Glass, and a host computer. It is tested in tissue-simulating phantoms and an ex vivo human breast tissue model. Our experiments demonstrate that the surgical navigation system provides useful guidance for localization and core needle biopsy of simulated tumor within the tissue-simulating phantom, as well as a core needle biopsy and subsequent excision of Indocyanine Green (ICG-fluorescing sentinel lymph nodes. Our experiments support the contention that this wearable goggle navigation system can be potentially very useful and fully integrated by the surgeon for optimizing many aspects of oncologic surgery. Further engineering optimization and additional in vivo clinical validation work is necessary before such a surgical navigation system can be fully realized in the everyday clinical setting.

  4. A novel fluoride anion modified gelatin nanogel system for ultrasound-triggered drug release.

    Science.gov (United States)

    Wu, Daocheng; Wan, Mingxi

    2008-01-01

    Controlled drug release, especially tumor-targeted drug release, remains a great challenge. Here, we prepare a novel fluoride anion-modified gelatin nanogel system and investigate its characteristics of ultrasound-triggered drug release. Adriamycin gelatin nanogel modified with fluoride anion (ADM-GNMF) was prepared by a modified co-precipitation method with fluoride anion and sodium sulfate. The loading and encapsulation efficiency of the anti-neoplastic agent adriamycin (ADM) were measured by high performance liquid chromatography (HPLC). The size and shape of ADM-GNMF were determined by electron microscopy and photo-correlation spectroscopy. The size distribution and drug release efficiency of ADM-GNMF, before and after sonication, were measured by two designed measuring devices that consisted of either a submicron particle size analyzer and an ultrasound generator as well as an ultrasound generator, automatic sampler, and HPLC. The ADM-GNMF was stable in solution with an average diameter of 46+/-12 nm; the encapsulation and loading efficiency of adriamycin were 87.2% and 6.38%, respectively. The ultrasound-triggered drug release and size change were most efficient at a frequency of 20 kHz, power density of 0.4w/cm2, and a 1~2 min duration. Under this ultrasound-triggered condition, 51.5% of drug in ADM-GNMF was released within 1~2 min, while the size of ADM-GNMF changed from 46 +/- 12 nm to 1212 +/- 35 nm within 1~2 min of sonication and restored to its previous size in 2~3 min after the ultrasound stopped. In contrast, 8.2% of drug in ADM-GNMF was released within 2~3 min without sonication, and only negligible size changes were found. The ADM-GNMF system efficiently released the encompassed drug in response to ultrasound, offering a novel and promising controlled drug release system for targeted therapy for cancer or other diseases.

  5. Preliminary Clinical Experience with a Combined Automated Breast Ultrasound and Digital Breast Tomosynthesis System.

    Science.gov (United States)

    Larson, Eric D; Lee, Won-Mean; Roubidoux, Marilyn A; Goodsitt, Mitchell M; Lashbrook, Chris; Davis, Cynthia E; Kripfgans, Oliver D; Carson, Paul L

    2018-03-01

    We analyzed the performance of a mammographically configured, automated breast ultrasound (McABUS) scanner combined with a digital breast tomosynthesis (DBT) system. The GE Invenia ultrasound system was modified for integration with GE DBT systems. Ultrasound and DBT imaging were performed in the same mammographic compression. Our small preliminary study included 13 cases, six of whom had contained invasive cancers. From analysis of these cases, current limitations and corresponding potential improvements of the system were determined. A registration analysis was performed to compare the ease of McABUS to DBT registration for this system with that of two systems designed previously. It was observed that in comparison to data from an earlier study, the McABUS-to-DBT registration alignment errors for both this system and a previously built combined system were smaller than those for a previously built standalone McABUS system. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored by Please ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... specific content. Related Articles and Media Sonohysterography Ultrasound - Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and ...

  9. SU-G-JeP3-08: Robotic System for Ultrasound Tracking in Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kuhlemann, I [University of Luebeck, Luebeck (Germany); Graduate School for Computing in Medicine and Life Sciences, University of Luebeck (Germany); Jauer, P; Schweikard, A; Ernst, F [University of Luebeck, Luebeck (Germany)

    2016-06-15

    Purpose: For safe and accurate real-time tracking of tumors for IGRT using 4D ultrasound, it is necessary to make use of novel, high-end force-sensitive lightweight robots designed for human-machine interaction. Such a robot will be integrated into an existing robotized ultrasound system for non-invasive 4D live tracking, using a newly developed real-time control and communication framework. Methods: The new KUKA LWR iiwa robot is used for robotized ultrasound real-time tumor tracking. Besides more precise probe contact pressure detection, this robot provides an additional 7th link, enhancing the dexterity of the kinematic and the mounted transducer. Several integrated, certified safety features create a safe environment for the patients during treatment. However, to remotely control the robot for the ultrasound application, a real-time control and communication framework has to be developed. Based on a client/server concept, client-side control commands are received and processed by a central server unit and are implemented by a client module running directly on the robot’s controller. Several special functionalities for robotized ultrasound applications are integrated and the robot can now be used for real-time control of the image quality by adjusting the transducer position, and contact pressure. The framework was evaluated looking at overall real-time capability for communication and processing of three different standard commands. Results: Due to inherent, certified safety modules, the new robot ensures a safe environment for patients during tumor tracking. Furthermore, the developed framework shows overall real-time capability with a maximum average latency of 3.6 ms (Minimum 2.5 ms; 5000 trials). Conclusion: The novel KUKA LBR iiwa robot will advance the current robotized ultrasound tracking system with important features. With the developed framework, it is now possible to remotely control this robot and use it for robotized ultrasound tracking

  10. SU-G-JeP3-08: Robotic System for Ultrasound Tracking in Radiation Therapy

    International Nuclear Information System (INIS)

    Kuhlemann, I; Jauer, P; Schweikard, A; Ernst, F

    2016-01-01

    Purpose: For safe and accurate real-time tracking of tumors for IGRT using 4D ultrasound, it is necessary to make use of novel, high-end force-sensitive lightweight robots designed for human-machine interaction. Such a robot will be integrated into an existing robotized ultrasound system for non-invasive 4D live tracking, using a newly developed real-time control and communication framework. Methods: The new KUKA LWR iiwa robot is used for robotized ultrasound real-time tumor tracking. Besides more precise probe contact pressure detection, this robot provides an additional 7th link, enhancing the dexterity of the kinematic and the mounted transducer. Several integrated, certified safety features create a safe environment for the patients during treatment. However, to remotely control the robot for the ultrasound application, a real-time control and communication framework has to be developed. Based on a client/server concept, client-side control commands are received and processed by a central server unit and are implemented by a client module running directly on the robot’s controller. Several special functionalities for robotized ultrasound applications are integrated and the robot can now be used for real-time control of the image quality by adjusting the transducer position, and contact pressure. The framework was evaluated looking at overall real-time capability for communication and processing of three different standard commands. Results: Due to inherent, certified safety modules, the new robot ensures a safe environment for patients during tumor tracking. Furthermore, the developed framework shows overall real-time capability with a maximum average latency of 3.6 ms (Minimum 2.5 ms; 5000 trials). Conclusion: The novel KUKA LBR iiwa robot will advance the current robotized ultrasound tracking system with important features. With the developed framework, it is now possible to remotely control this robot and use it for robotized ultrasound tracking

  11. Toward a real-time system for temporal enhanced ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Azizi, Shekoofeh; Van Woudenberg, Nathan; Sojoudi, Samira; Li, Ming; Xu, Sheng; Abu Anas, Emran M; Yan, Pingkun; Tahmasebi, Amir; Kwak, Jin Tae; Turkbey, Baris; Choyke, Peter; Pinto, Peter; Wood, Bradford; Mousavi, Parvin; Abolmaesumi, Purang

    2018-03-27

    We have previously proposed temporal enhanced ultrasound (TeUS) as a new paradigm for tissue characterization. TeUS is based on analyzing a sequence of ultrasound data with deep learning and has been demonstrated to be successful for detection of cancer in ultrasound-guided prostate biopsy. Our aim is to enable the dissemination of this technology to the community for large-scale clinical validation. In this paper, we present a unified software framework demonstrating near-real-time analysis of ultrasound data stream using a deep learning solution. The system integrates ultrasound imaging hardware, visualization and a deep learning back-end to build an accessible, flexible and robust platform. A client-server approach is used in order to run computationally expensive algorithms in parallel. We demonstrate the efficacy of the framework using two applications as case studies. First, we show that prostate cancer detection using near-real-time analysis of RF and B-mode TeUS data and deep learning is feasible. Second, we present real-time segmentation of ultrasound prostate data using an integrated deep learning solution. The system is evaluated for cancer detection accuracy on ultrasound data obtained from a large clinical study with 255 biopsy cores from 157 subjects. It is further assessed with an independent dataset with 21 biopsy targets from six subjects. In the first study, we achieve area under the curve, sensitivity, specificity and accuracy of 0.94, 0.77, 0.94 and 0.92, respectively, for the detection of prostate cancer. In the second study, we achieve an AUC of 0.85. Our results suggest that TeUS-guided biopsy can be potentially effective for the detection of prostate cancer.

  12. Compensated Row-Column Ultrasound Imaging System Using Multilayered Edge Guided Stochastically Fully Connected Random Fields.

    Science.gov (United States)

    Ben Daya, Ibrahim; Chen, Albert I H; Shafiee, Mohammad Javad; Wong, Alexander; Yeow, John T W

    2017-09-06

    The row-column method received a lot of attention for 3-D ultrasound imaging. By reducing the number of connections required to address the 2-D array and therefore reducing the amount of data to handle, this addressing method allows for real time 3-D imaging. Row-column still has its limitations: the issues of sparsity, speckle noise inherent to ultrasound, the spatially varying point spread function, and the ghosting artifacts inherent to the row-column method must all be taken into account when building a reconstruction framework. In this research, we build on a previously published system and propose an edge-guided, compensated row-column ultrasound imaging system that incorporates multilayered edge-guided stochastically fully connected conditional random fields to address the limitations of the row-column method. Tests carried out on simulated and real row-column ultrasound images show the effectiveness of our proposed system over other published systems. Visual assessment show our proposed system's potential at preserving edges and reducing speckle. Quantitative analysis shows that our proposed system outperforms previously published systems when evaluated with metrics such as Peak Signal-to-Noise Ratio, Coefficient of Correlation, and Effective Number of Looks. These results show the potential of our proposed system as an effective tool for enhancing 3-D row-column imaging.

  13. An experimental system for the study of ultrasound exposure of isolated blood vessels

    NARCIS (Netherlands)

    Tokarczyk, Anna; Rivens, Ian; van Bavel, E.; Symonds-Tayler, Richard; ter Haar, Gail

    2013-01-01

    An experimental system designed for the study of the effects of diagnostic or therapeutic ultrasound exposure on isolated blood vessels in the presence or absence of intraluminal contrast agent is described. The system comprised several components. A microscope was used to monitor vessel size (and

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls of the uterus). Sonohysterography allows for a ... and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. ...

  15. First clinical experience with a dedicated MRI-guided high-intensity focused ultrasound system for breast cancer ablation

    Energy Technology Data Exchange (ETDEWEB)

    Merckel, Laura G.; Knuttel, Floor M.; Peters, Nicky H.G.M.; Mali, Willem P.T.M.; Bosch, Maurice A.A.J. van den [University Medical Center Utrecht, Department of Radiology, HP E 01.132, Utrecht (Netherlands); Deckers, Roel; Moonen, Chrit T.W.; Bartels, Lambertus W. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Dalen, Thijs van [Diakonessenhuis Utrecht, Department of Surgery, Utrecht (Netherlands); Schubert, Gerald [Philips Healthcare, Best (Netherlands); Weits, Teun [Diakonessenhuis Utrecht, Department of Radiology, Utrecht (Netherlands); Diest, Paul J. van [University Medical Center Utrecht, Department of Pathology, Utrecht (Netherlands); Vaessen, Paul H.H.B. [University Medical Center Utrecht, Department of Anesthesiology, Utrecht (Netherlands); Gorp, Joost M.H.H. van [Diakonessenhuis Utrecht, Department of Pathology, Utrecht (Netherlands)

    2016-11-15

    To assess the safety and feasibility of MRI-guided high-intensity focused ultrasound (MR-HIFU) ablation in breast cancer patients using a dedicated breast platform. Patients with early-stage invasive breast cancer underwent partial tumour ablation prior to surgical resection. MR-HIFU ablation was performed using proton resonance frequency shift MR thermometry and an MR-HIFU system specifically designed for breast tumour ablation. The presence and extent of tumour necrosis was assessed by histopathological analysis of the surgical specimen. Pearson correlation coefficients were calculated to assess the relationship between sonication parameters, temperature increase and size of tumour necrosis at histopathology. Ten female patients underwent MR-HIFU treatment. No skin redness or burns were observed in any of the patients. No correlation was found between the applied energy and the temperature increase. In six patients, tumour necrosis was observed with a maximum diameter of 3-11 mm. In these patients, the number of targeted locations was equal to the number of areas with tumour necrosis. A good correlation was found between the applied energy and the size of tumour necrosis at histopathology (Pearson = 0.76, p = 0.002). Our results show that MR-HIFU ablation with the dedicated breast system is safe and results in histopathologically proven tumour necrosis. (orig.)

  16. Obstetrical ultrasound data-base management system by using personal computer

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Park, Jeong Hee; Kim, Soo Nyung

    1993-01-01

    A computer program which performs obstetric calculations on Clipper Language using the data from ultrasonography was developed for personal computer. It was designed for fast assessment of fetal development, prediction of gestational age, and weight from ultrasonographic measurements which included biparietal diameter, femur length, gestational sac, occipito-frontal diameter, abdominal diameter, and etc. The Obstetrical-Ultrasound Data-Base Management System was tested for its performance. The Obstetrical-Ultrasound Data-Base Management System was very useful in patient management with its convenient data filing, easy retrieval of previous report, prompt but accurate estimation of fetal growth and skeletal anomaly and production of equation and growth curve for pregnant women

  17. Modeling of higher harmonics formation in medical ultrasound systems

    DEFF Research Database (Denmark)

    Taylor, Louise Kold; Schlaikjer, Malene; Jensen, Jørgen Arendt

    2002-01-01

    a valuable tool for simulating ultrasound harmonic imaging. An extended version of Field II is obtained by means of operator splitting. The pressure eld is calculated by propagation of the eld from the transducer through a number of planes. Every plane serves as a virtual aperture for the next plane...... of the approach is demonstrated by comparing results from simulations and measurements from a convex array transducer. The new simulation tool is capable of simulating the formation of higher harmonics in water on the acoustical axis. The generation of nonlinear higher harmonic components can be predicted...

  18. Three-dimensional micro electromechanical system piezoelectric ultrasound transducer

    Science.gov (United States)

    Hajati, Arman; Latev, Dimitre; Gardner, Deane; Hajati, Azadeh; Imai, Darren; Torrey, Marc; Schoeppler, Martin

    2012-12-01

    Here we present the design and experimental acoustic test data for an ultrasound transducer technology based on a combination of micromachined dome-shaped piezoelectric resonators arranged in a flexible architecture. Our high performance niobium-doped lead zirconate titanate film is implemented in three-dimensional dome-shaped structures, which form the basic resonating cells. Adjustable frequency response is realized by mixing these basic cells and modifying their dimensions by lithography. Improved characteristics such as high sensitivity, adjustable wide-bandwidth frequency response, low transmit voltage compatible with ordinary integrated circuitry, low electrical impedance well matched to coaxial cabling, and intrinsic acoustic impedance match to water are demonstrated.

  19. Accuracy and safety of ward based pleural ultrasound in the Australian healthcare system.

    Science.gov (United States)

    Hammerschlag, Gary; Denton, Matthew; Wallbridge, Peter; Irving, Louis; Hew, Mark; Steinfort, Daniel

    2017-04-01

    Ultrasound has been shown to improve the accuracy and safety of pleural procedures. Studies to date have been performed in large, specialized units, where pleural procedures are performed by a small number of highly specialized physicians. There are no studies examining the safety and accuracy of ultrasound in the Australian healthcare system where procedures are performed by junior doctors with a high staff turnover. We performed a retrospective review of the ultrasound database in the Respiratory Department at the Royal Melbourne Hospital to determine accuracy and complications associated pleural procedures. A total of 357 ultrasounds were performed between October 2010 and June 2013. Accuracy of pleural procedures was 350 of 356 (98.3%). Aspiration of pleural fluid was successful in 121 of 126 (96%) of patients. Two (0.9%) patients required chest tube insertion for management of pneumothorax. There were no recorded pleural infections, haemorrhage or viscera puncture. Ward-based ultrasound for pleural procedures is safe and accurate when performed by appropriately trained and supported junior medical officers. Our findings support this model of pleural service care in the Australian healthcare system. © 2016 Asian Pacific Society of Respirology.

  20. Feasibility of Electronic Nicotine Delivery Systems in Surgical Patients.

    Science.gov (United States)

    Nolan, Margaret; Leischow, Scott; Croghan, Ivana; Kadimpati, Sandeep; Hanson, Andrew; Schroeder, Darrell; Warner, David O

    2016-08-01

    Cigarette smoking is a known risk factor for postoperative complications. Quitting or cutting down on cigarettes around the time of surgery may reduce these risks. This study aimed to determine the feasibility of using electronic nicotine delivery systems (ENDS) to help patients achieve this goal, regardless of their intent to attempt long-term abstinence. An open-label observational study was performed of cigarette smoking adults scheduled for elective surgery at Mayo Clinic Rochester and seen in the pre-operative evaluation clinic between December 2014 and June 2015. Subjects were given a supply of ENDS to use prior to and 2 weeks after surgery. They were encouraged to use them whenever they craved a cigarette. Daily use of ENDS was recorded, and patients were asked about smoking behavior and ENDS use at baseline, 14 days and 30 days. Of the 105 patients approached, 80 (76%) agreed to participate; five of these were later excluded. Among the 75, 67 (87%) tried ENDS during the study period. At 30-day follow-up, 34 (51%) who had used ENDS planned to continue using them. Average cigarette consumption decreased from 15.6 per person/d to 7.6 over the study period (P < .001). At 30 days, 11/67 (17%) reported abstinence from cigarettes. ENDS use is feasible in adult smokers scheduled for elective surgery and is associated with a reduction in perioperative cigarette consumption. These results support further exploration of ENDS as a means to help surgical patients reduce or eliminate their cigarette consumption around the time of surgery. Smoking in the perioperative period increases patients' risk for surgical complications and healing difficulties, but new strategies are needed to help patients quit or cut down during this stressful time. These pilot data suggest that ENDS use is feasible and well-accepted in surgical patients, and worthy of exploration as a harm reduction strategy in these patients. © The Author 2016. Published by Oxford University Press on behalf of

  1. Potential use of an ultrasound antifouling technology as a ballast water treatment system

    Science.gov (United States)

    Estévez-Calvar, Noelia; Gambardella, Chiara; Miraglia, Francesco; Pavanello, Giovanni; Greco, Giuliano; Faimali, Marco; Garaventa, Francesca

    2018-03-01

    The aim of this study was to investigate, at a laboratory scale, the potentialities of an ultrasound-based treatment initially designed to eliminate fouling, as a ballast water treatment system. Therefore, early life stages of three different zooplanktonic species (Amphibalanus amphitrite, Brachionus plicatilis and Artemia salina) were exposed to ultrasound waves (20-22 kHz). The experimental set up included static assays with variations of time exposure (30 s, 60 s and 30 s on/60 s off/30 s on), material of tanks (stainless steel, galvanized steel and plastic) and position of the ultrasound source. Results showed that the treatment efficacy increased from 30 to 60 s and no differences were registered between 60 s-continuous exposure and pulse exposure. The highest efficacy was observed in Experiment I (metal-to-metal contact assay) with a mortality value of 93-95% for B. plicatilis and A. salina. It consisted of organisms located inside stainless steel tubes that were located in direct contact with the ultrasound source and treated for 60 s. Further, we found that, generally, A. amphitrite and B. plicatilis were the most resistant species to the ultrasound treatment whereas A. salina was the most sensitive. We further discuss that US may unlikely be used for commercial vessels, but may be used to treat ballast water in smaller ballast tanks as on board of mega yachts.

  2. Evaluation of a Novel Wireless Transmission System for Trauma Ultrasound Examinations From Moving Ambulances.

    Science.gov (United States)

    Morchel, Herman; Ogedegbe, Chinwe; Chaplin, William; Cheney, Brianna; Zakharchenko, Svetlana; Misch, David; Schwartz, Matthew; Feldman, Joseph; Kaul, Sanjeev

    2018-03-01

    To determine if physicians trained in ultrasound interpretation perceive a difference in image quality and usefulness between Extended Focused Assessment with Sonography ultrasound examinations performed at bedside in a hospital vs. by emergency medical technicians minimally trained in medical ultrasound on a moving ambulance and transmitted to the hospital via a novel wireless system. In particular, we sought to demonstrate that useful images could be obtained from patients in less than optimal imaging conditions; that is, while they were in transport. Emergency medical technicians performed the examinations during transport of blunt trauma patients. Upon patient arrival at the hospital, a bedside Extended Focused Assessment with Sonography examination was performed by a physician. Both examinations were recorded and later reviewed by physicians trained in ultrasound interpretation. Data were collected on 20 blunt trauma patients over a period of 13 mo. Twenty ultrasound-trained physicians blindly compared transmitted vs. bedside images using 11 Questionnaire for User Interaction Satisfaction scales. Four paired samples t-tests were conducted to assess mean differences between ratings for ambulatory and base images. Although there is a slight tendency for the average rating across all subjects and raters to be slightly higher in the base than in the ambulatory condition, none of these differences are statistically significant. These results suggest that the quality of the ambulatory images was viewed as essentially as good as the quality of the base images.

  3. Verification and compensation of respiratory motion using an ultrasound imaging system

    International Nuclear Information System (INIS)

    Chuang, Ho-Chiao; Hsu, Hsiao-Yu; Chiu, Wei-Hung; Tien, Der-Chi; Wu, Ren-Hong; Hsu, Chung-Hsien

    2015-01-01

    Purpose: The purpose of this study was to determine if it is feasible to use ultrasound imaging as an aid for moving the treatment couch during diagnosis and treatment procedures associated with radiation therapy, in order to offset organ displacement caused by respiratory motion. A noninvasive ultrasound system was used to replace the C-arm device during diagnosis and treatment with the aims of reducing the x-ray radiation dose on the human body while simultaneously being able to monitor organ displacements. Methods: This study used a proposed respiratory compensating system combined with an ultrasound imaging system to monitor the compensation effect of respiratory motion. The accuracy of the compensation effect was verified by fluoroscopy, which means that fluoroscopy could be replaced so as to reduce unnecessary radiation dose on patients. A respiratory simulation system was used to simulate the respiratory motion of the human abdomen and a strain gauge (respiratory signal acquisition device) was used to capture the simulated respiratory signals. The target displacements could be detected by an ultrasound probe and used as a reference for adjusting the gain value of the respiratory signal used by the respiratory compensating system. This ensured that the amplitude of the respiratory compensation signal was a faithful representation of the target displacement. Results: The results show that performing respiratory compensation with the assistance of the ultrasound images reduced the compensation error of the respiratory compensating system to 0.81–2.92 mm, both for sine-wave input signals with amplitudes of 5, 10, and 15 mm, and human respiratory signals; this represented compensation of the respiratory motion by up to 92.48%. In addition, the respiratory signals of 10 patients were captured in clinical trials, while their diaphragm displacements were observed simultaneously using ultrasound. Using the respiratory compensating system to offset, the diaphragm

  4. Use of Ultrasound Elastography in the Assessment of the Musculoskeletal System

    International Nuclear Information System (INIS)

    Paluch, Łukasz; Nawrocka-Laskus, Ewa; Wieczorek, Janusz; Mruk, Bartosz; Frel, Małgorzata; Walecki, Jerzy

    2016-01-01

    This article presents possible applications of ultrasound elastography in musculoskeletal imaging based on the available literature, as well as the possibility of extending indications for the use of elastography in the future. Ultrasound elastography (EUS) is a new method that shows structural changes in tissues following application of physical stress. Elastography techniques have been widely used to assess muscles and tendons in vitro since the early parts of the twentieth century. Only recently with the advent of new technology and creation of highly specialized ultrasound devices, has elastography gained widespread use in numerous applications. The authors performed a search of the Medline/PubMed databases for original research and reviewed publications on the application of ultrasound elastography for musculoskeletal imaging. All publications demonstrate possible uses of ultrasound elastography in examinations of the musculoskeletal system. The most widely studied areas include the muscles, tendons and rheumatic diseases. There are also reports on the employment in vessel imaging. The main limitation of elastography as a technique is above all the variability of applied pressure during imaging, which is operator-dependent. It would therefore be reasonable to provide clear guidelines on the technique applied, as well as clear indications for performing the test. It is important to develop methods for creating artifact-free, closed-loop, compression-decompression cycles. The main advantages include cost-effectiveness, short duration of the study, non-invasive nature of the procedure, as well as a potentially broader clinical availability. There are no clear guidelines with regard to indications as well as examination techniques. Ultrasound elastography is a new and still poorly researched method. We conclude, however, that it can be widely used in the examinations of musculoskeletal system. Therefore, it is necessary to conduct large, multi-center studies to

  5. System-Level Design of an Integrated Receiver Front End for a Wireless Ultrasound Probe

    DEFF Research Database (Denmark)

    di Ianni, Tommaso; Hemmsen, Martin Christian; Llimos Muntal, Pere

    2016-01-01

    In this paper, a system-level design is presented for an integrated receive circuit for a wireless ultrasound probe, which includes analog front ends and beamformation modules. This paper focuses on the investigation of the effects of architectural design choices on the image quality. The point...

  6. Peritendinous calcinosis of calcaneus tendon associated with dermatomyositis: correlation between conventional radiograph, ultrasound, magnetic resonance imaging and gross surgical pathology; Calcinose peritendinea do tendao calcaneo associada a dermatomiosite: correlacao entre radiografia convencional, ultra-sonografia, ressonancia magnetica e macroscopia cirurgica

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, Ana Claudia Ferreira; Gomide, Lidyane Marques de Paula; Lemes, Marcella Stival [Universidade Federal de Goias (UFG), Goiana, GO (Brazil). Faculdade de Medicina. Hospital das Clinicas; Costa, Edegmar Nunes; Rocha, Valney Luiz da [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Faculdade de Medicina. Dept. de Ortopedia; Machado, Marcio Martins; Santos Junior, Rubens Carneiro dos; Barros, Nestor de; Cerri, Giovanni Guido [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Faculdade de Medicina. Dept. de Radiologia; Sernik, Renato Antonio [Sao Paulo Univ., SP (Brazil). Hospital das Clinicas. Inst. de Radiologia; Nunes, Rodrigo Alvarenga [Universidade do Vale do Sapucai (UNIVAS), Pouso Alegre, MG (Brazil). Faculdade de Ciencias Medicas; Albieri, Alexandre Daher [Hospital de Acidentados de Goiania, GO (Brazil)

    2006-01-15

    Interstitial calcinosis is an uncommon condition in which there is either localized or widely disseminated deposition of calcium in the skin, subcutaneous tissues, muscles, and tendons. Calcinosis is often associated with collagen diseases, scleroderma and dermatomyositis. The authors report a case of interstitial calcinosis associated with dermatomyositis studied with conventional radiograph, ultrasound and magnetic resonance imaging, and correlate the imaging findings with the results of surgical pathology gross examination. (author)

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to ... Ultrasound Imaging? What is Ultrasound Imaging of the Prostate? Ultrasound is safe and painless, and produces pictures ...

  8. The feasibility of an infrared system for real-time visualization and mapping of ultrasound fields

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, Adam; Nunn, John, E-mail: adam.shaw@npl.co.u [National Physical Laboratory, Teddington, Middlesex, TW11 0LW (United Kingdom)

    2010-06-07

    In treatment planning for ultrasound therapy, it is desirable to know the 3D structure of the ultrasound field. However, mapping an ultrasound field in 3D is very slow, with even a single planar raster scan taking typically several hours. Additionally, hydrophones that are used for field mapping are expensive and can be damaged in some therapy fields. So there is value in rapid methods which enable visualization and mapping of the ultrasound field in about 1 min. In this note we explore the feasibility of mapping the intensity distribution by measuring the temperature distribution produced in a thin sheet of absorbing material. A 0.2 mm thick acetate sheet forms a window in the wall of a water tank containing the transducer. The window is oriented at 45{sup 0} to the beam axis, and the distance from the transducer to the window can be varied. The temperature distribution is measured with an infrared camera; thermal images of the inclined plane could be viewed in real time or images could be captured for later analysis and 3D field reconstruction. We conclude that infrared thermography can be used to gain qualitative information about ultrasound fields. Thermal images are easily visualized with good spatial and thermal resolutions (0.044 mm and 0.05 {sup 0}C in our system). The focus and field structure such as side lobes can be identified in real time from the direct video output. 3D maps and image planes at arbitrary orientations to the beam axis can be obtained and reconstructed within a few minutes. In this note we are primarily interested in the technique for characterization of high intensity focused ultrasound (HIFU) fields, but other applications such as physiotherapy fields are also possible. (note)

  9. The feasibility of an infrared system for real-time visualization and mapping of ultrasound fields

    International Nuclear Information System (INIS)

    Shaw, Adam; Nunn, John

    2010-01-01

    In treatment planning for ultrasound therapy, it is desirable to know the 3D structure of the ultrasound field. However, mapping an ultrasound field in 3D is very slow, with even a single planar raster scan taking typically several hours. Additionally, hydrophones that are used for field mapping are expensive and can be damaged in some therapy fields. So there is value in rapid methods which enable visualization and mapping of the ultrasound field in about 1 min. In this note we explore the feasibility of mapping the intensity distribution by measuring the temperature distribution produced in a thin sheet of absorbing material. A 0.2 mm thick acetate sheet forms a window in the wall of a water tank containing the transducer. The window is oriented at 45 0 to the beam axis, and the distance from the transducer to the window can be varied. The temperature distribution is measured with an infrared camera; thermal images of the inclined plane could be viewed in real time or images could be captured for later analysis and 3D field reconstruction. We conclude that infrared thermography can be used to gain qualitative information about ultrasound fields. Thermal images are easily visualized with good spatial and thermal resolutions (0.044 mm and 0.05 0 C in our system). The focus and field structure such as side lobes can be identified in real time from the direct video output. 3D maps and image planes at arbitrary orientations to the beam axis can be obtained and reconstructed within a few minutes. In this note we are primarily interested in the technique for characterization of high intensity focused ultrasound (HIFU) fields, but other applications such as physiotherapy fields are also possible. (note)

  10. Making surgical missions a joint operation: NGO experiences of visiting surgical teams and the formal health care system in Guatemala.

    Science.gov (United States)

    Roche, Stephanie; Hall-Clifford, Rachel

    2015-01-01

    Each year, thousands of Guatemalans receive non-emergent surgical care from short-term medical missions (STMMs) hosted by local non-governmental organizations (NGOs) and staffed by foreign visiting medical teams (VMTs). The purpose of this study was to explore the perspectives of individuals based in NGOs involved in the coordination of surgical missions to better understand how these missions articulate with the larger Guatemalan health care system. During the summers of 2011 and 2013, in-depth interviews were conducted with 25 representatives from 11 different Guatemalan NGOs with experience with surgical missions. Transcripts were analysed for major themes using an inductive qualitative data analysis process. NGOs made use of the formal health care system but were limited by several factors, including cost, issues of trust and current ministry of health policy. Participants viewed the government health care system as a potential resource and expressed a desire for more collaboration. The current practices of STMMs are not conducive to health system strengthening. The role of STMMs must be defined and widely understood by all stakeholders in order to improve patient safety and effectively utilise health resources. Priority should be placed on aligning the work of VMTs with that of the larger health care system.

  11. The da vinci robot system eliminates multispecialty surgical trainees' hand dominance in open and robotic surgical settings.

    Science.gov (United States)

    Badalato, Gina M; Shapiro, Edan; Rothberg, Michael B; Bergman, Ari; RoyChoudhury, Arindam; Korets, Ruslan; Patel, Trushar; Badani, Ketan K

    2014-01-01

    Handedness, or the inherent dominance of one hand's dexterity over the other's, is a factor in open surgery but has an unknown importance in robot-assisted surgery. We sought to examine whether the robotic surgery platform could eliminate the effect of inherent hand preference. Residents from the Urology and Obstetrics/Gynecology departments were enrolled. Ambidextrous and left-handed subjects were excluded. After completing a questionnaire, subjects performed three tasks modified from the Fundamentals of Laparoscopic Surgery curriculum. Tasks were performed by hand and then with the da Vinci robotic surgical system (Intuitive Surgical, Sunnyvale, California). Participants were randomized to begin with using either the left or the right hand, and then switch. Left:right ratios were calculated from scores based on time to task completion. Linear regression analysis was used to determine the significance of the impact of surgical technique on hand dominance. Ten subjects were enrolled. The mean difference in raw score performance between the right and left hands was 12.5 seconds for open tasks and 8 seconds for robotic tasks (Probot tasks, respectively (Probotic and open approaches for raw time scores (Phand, prior robotic experience, and comfort level. These findings remain to be validated in larger cohorts. The robotic technique reduces hand dominance in surgical trainees across all task domains. This finding contributes to the known advantages of robotic surgery.

  12. A ferromagnetic surgical system reduces phrenic nerve injury in redo congenital cardiac surgery.

    Science.gov (United States)

    Shinkawa, Takeshi; Holloway, Jessica; Tang, Xinyu; Gossett, Jeffrey M; Imamura, Michiaki

    2017-05-01

    A ferromagnetic surgical system (FMwand®) is a new type of dissection device expected to reduce the risk of adjacent tissue damage. We reviewed 426 congenital cardiac operations with cardiopulmonary bypass through redo sternotomy to assess if this device prevented phrenic nerve injury. The ferromagnetic surgical system was used in 203 operations (47.7%) with regular electrocautery and scissors. The preoperative and operative details were similar between the operations with or without the ferromagnetic surgical system. The incidence of phrenic nerve injury was significantly lower with the ferromagnetic surgical system (0% vs 2.7%, P = 0.031). A logistic regression model showed that the use of the ferromagnetic surgical system was significantly associated with reduced odds of phrenic nerve injury (P < 0.001). © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  13. Ultrasound assisted combustion synthesis of TiC in Al-Ti-C system.

    Science.gov (United States)

    Liu, Zhiwei; Rakita, Milan; Xu, Wilson; Wang, Xiaoming; Han, Qingyou

    2015-11-01

    This research investigated the effects of high-intensity ultrasound on the combustion synthesis of TiC particles in Al-Ti-C system. The process involved that high-intensity ultrasound was applied on the surface of a compacted Al-Ti-C pellet directly through a Nb probe during the thermal explosion reaction. By comparing with the sample without ultrasonic treatment, it was found that the thermal explosion reaction for synthesizing TiC phase could take place thoroughly in the ultrasonically treated sample. During the process of synthesizing TiC phase, the dissolution of solid graphite particles into the Al-Ti melt, as well as the nucleation and growth of TiC particles could be promoted effectively due to the effects of ultrasound, leading to an enhancement of the formation of TiC particles. Ultrasound assisted combustion synthesis as a simple and effective approach was proposed for synthesizing materials in this research. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Round Robin Test for Performance Demonstration System of Ultrasound Examination Personnel in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kim, Young Ho; Yang, Seung Han; Kim, Yong Sik; Yoon, Byung Sik; Lee, Hee Jong

    2005-01-01

    Ultrasound testing performance during in-service inspection for the main components of NPPs is strongly affected by each examination person. Therefore, ASME established a more strict qualification requirement in Sec. XI Appendix VIII for the ultrasound testing personnel in nuclear power plants. The Korean Performance Demonstration (KPD) System according to the ASME code for the ultrasonic testing personnel, equipments, and procedures to apply to the Class 1 and 2 piping ultrasound examination of nuclear power plants in Korea was established. And a round robin test was conducted in order to verify the effectiveness of PD method by comparing the examination results from the method of Performance Demonstration (PD) and a traditional ASME code dB-drop method. The round robin test shows that the reliability of the PD method is better than that of the dB-drop method. As a result, application of the PD method to the in-service inspection of the nuclear power plants will improve the performance of ultrasound testing

  15. Bipolar-power-transistor-based limiter for high frequency ultrasound imaging systems.

    Science.gov (United States)

    Choi, Hojong; Yang, Hao-Chung; Shung, K Kirk

    2014-03-01

    High performance limiters are described in this paper for applications in high frequency ultrasound imaging systems. Limiters protect the ultrasound receiver from the high voltage (HV) spikes produced by the transmitter. We present a new bipolar power transistor (BPT) configuration and compare its design and performance to a diode limiter used in traditional ultrasound research and one commercially available limiter. Limiter performance depends greatly on the insertion loss (IL), total harmonic distortion (THD) and response time (RT), each of which will be evaluated in all the limiters. The results indicated that, compared with commercial limiter, BPT-based limiter had less IL (-7.7 dB), THD (-74.6 dB) and lower RT (43 ns) at 100 MHz. To evaluate the capability of these limiters, they were connected to a 100 MHz single element transducer and a two-way pulse-echo test was performed. It was found that the -6 dB bandwidth and sensitivity of the transducer using BPT-based limiter were better than those of the commercial limiter by 22% and 140%, respectively. Compared to the commercial limiter, BPT-based limiter is shown to be capable of minimizing signal attenuation, RT and THD at high frequencies and is thus suited for high frequency ultrasound applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Role of RENAL nephrometry scoring system in planning surgical intervention in patients with localized renal mas

    OpenAIRE

    Mohamed Samir Shaaban; Tamer Mohammed Abou Youssif; Ahmed Mostafa; Hossam Eldin Hegazy; Mohammed Adel Atta

    2015-01-01

    Purpose: The study was designed to validate the value of preoperative planning using RENAL nephrometry scoring system in patients having organ confined renal tumors and undergoing surgical intervention and to assess its correlation with the surgical technique. Patient and methods: Forty patients with organ-confined renal masses underwent RENAL nephrometry scoring which was correlated with the surgical technique either radical or nephron-sparing surgery. Result: RENAL nephrometry scoring...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, also called transrectal ultrasound, provides ...

  18. Orthognathic positioning system: intraoperative system to transfer virtual surgical plan to operating field during orthognathic surgery.

    Science.gov (United States)

    Polley, John W; Figueroa, Alvaro A

    2013-05-01

    To introduce the concept and use of an occlusal-based "orthognathic positioning system" (OPS) to be used during orthognathic surgery. The OPS consists of intraoperative occlusal-based devices that transfer virtual surgical planning to the operating field for repositioning of the osteotomized dentoskeletal segments. The system uses detachable guides connected to an occlusal splint. An initial drilling guide is used to establish stable references or landmarks. These are drilled on the bone that will not be repositioned adjacent to the osteotomy line. After mobilization of the skeletal segment, a final positioning guide, referenced to the drilled landmarks, is used to transfer the skeletal segment according to the virtual surgical planning. The OPS is digitally designed using 3-dimensional computer-aided design/computer-aided manufacturing technology and manufactured with stereolithographic techniques. Virtual surgical planning has improved the preoperative assessment and, in conjunction with the OPS, the execution of orthognathic surgery. The OPS has the possibility to eliminate the inaccuracies commonly associated with traditional orthognathic surgery planning and to simplify the execution by eliminating surgical steps such as intraoperative measuring, determining the condylar position, the use of bulky intermediate splints, and the use of intermaxillary wire fixation. The OPS attempts precise translation of the virtual plan to the operating field, bridging the gap between virtual and actual surgery. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. System Level Design of a Continuous-Time Delta-Sigma Modulator for Portable Ultrasound Scanners

    DEFF Research Database (Denmark)

    Llimos Muntal, Pere; Færch, Kjartan; Jørgensen, Ivan Harald Holger

    2015-01-01

    In this paper the system level design of a continuous-time ∆Σ modulator for portable ultrasound scanners is presented. The overall required signal-to-noise ratio (SNR) is derived to be 42 dB and the sampling frequency used is 320 MHz for an oversampling ratio of 16. In order to match these requir......, based on high-level VerilogA simulations, the performance of the ∆Σ modulator versus various block performance parameters is presented as trade-off curves. Based on these results, the block specifications are derived.......In this paper the system level design of a continuous-time ∆Σ modulator for portable ultrasound scanners is presented. The overall required signal-to-noise ratio (SNR) is derived to be 42 dB and the sampling frequency used is 320 MHz for an oversampling ratio of 16. In order to match...

  20. Mesh three-dimensional arm orthosis with built-in ultrasound physiotherapy system

    Science.gov (United States)

    Kashapova, R. M.; Kashapov, R. N.; Kashapova, R. S.

    2017-09-01

    The possibility of using the built-in ultrasound physiotherapy system of the hand orthosis is explored in the work. The individual mesh orthosis from nylon 12 was manufactured by the 3D prototyping method on the installation of selective laser sintering SLS SPro 60HD. The applied technology of three-dimensional scanning made it possible to obtain a model of the patient’s hand and on the basis of it to build a virtual model of the mesh frame. In the course of the research, the developed system of ultrasound exposure was installed on the orthosis and its tests were carried out. As a result, the acceleration of the healing process and the reduction in the time of wearing orthosis were found.

  1. New ultrasound stone locking system in extracorporeal lithotripsy: Decreased duration of fluoroscopy and radiation doses

    International Nuclear Information System (INIS)

    Abid, N.; Ravier, E.; Codas, R.; Crouzet, S.; Martin, X.

    2013-01-01

    Extracorporeal shock wave lithotripsy is the most common method of treatment for kidney stones. Both fluoroscopy and ultrasound imaging can be used to locate stones, but fluoroscopy is more frequently employed. Evaluation of a new stereotaxic navigational system: the stone was located using an ultrasound probe, and its 3D location was saved. The table automatically moved to position the stone at the focal point. A real-time follow-up was possible during treatment. Our objective was to demonstrate a decrease in the use of fluoroscopy to locate kidney stones for extracorporeal shock wave lithotripsy through the use of a 3D ultrasound stone locking system. Prospective analysis of the case records of the 20 patients preceding and the 20 patients succeeding the arrival of the ultrasound stone locking system Visio-Track (EDAP-TMS). We used a Student test to compare age, BMI, kidney stone size, number of shock waves and administered energy. Patient characteristics were comparable. The average age was 55 years old and the average kidney stone size was 10.7 mm. Radiation duration was 174.8 seconds in the group without Visio-Track versus 57.1 seconds in the group with it (P < 0.0001). A similar result was observed for radiation doses: 5197.25 mGy.cm 2 for the group without versus 1987.6 mGy.cm 2 for the group with Visio-Track (P ≡ 0.0033). The stone locking system Visio-Track reduced fluoroscopy in our first group of patients, which decreased the patient's individual absorbed irradiation dose. (authors)

  2. The SEP "Robot": A Valid Virtual Reality Robotic Simulator for the Da Vinci Surgical System?

    NARCIS (Netherlands)

    van der Meijden, O. A. J.; Broeders, I. A. M. J.; Schijven, M. P.

    2010-01-01

    The aim of the study was to determine if the concept of face and construct validity may apply to the SurgicalSim Educational Platform (SEP) "robot" simulator. The SEP robot simulator is a virtual reality (VR) simulator aiming to train users on the Da Vinci Surgical System. To determine the SEP's

  3. Clinical diagnostic ultrasound

    International Nuclear Information System (INIS)

    Barnett, E.; Morley, P.

    1986-01-01

    This textbook on diagnostic ultrasound covers the main systems, with emphasis being placed on the clinical application of diagnostic ultrasound in everyday practice. It provides not only a textbook for postgraduates (particularly FRCR candidates), but also a reference work for practitioners of clinical ultrasound and clinicians generally

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound or with a rectal examination, an ultrasound-guided biopsy can be performed. This procedure involves advancing ... of the Prostate) Prostate Cancer Ultrasound- and MRI-Guided Prostate Biopsy Images related to Ultrasound - Prostate Sponsored ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to produce pictures of the structures and ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Z Ultrasound - Prostate Ultrasound of the prostate uses sound waves to produce pictures of a man’s prostate ... pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound scanning or ...

  7. Ultrasound -- Pelvis

    Science.gov (United States)

    ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  8. An experimental system for the study of ultrasound exposure of isolated blood vessels

    International Nuclear Information System (INIS)

    Tokarczyk, Anna; Rivens, Ian; Symonds-Tayler, Richard; Ter Haar, Gail; Van Bavel, E

    2013-01-01

    An experimental system designed for the study of the effects of diagnostic or therapeutic ultrasound exposure on isolated blood vessels in the presence or absence of intraluminal contrast agent is described. The system comprised several components. A microscope was used to monitor vessel size (and thus vessel functionality), and potential leakage of intraluminal 70 kDa FITC-dextran fluorescence marker. A vessel chamber allowed the mounting of an isolated vessel whilst maintaining its viability, with pressure regulation for the control of intraluminal pressure and induction of flow for the infusion of contrast microbubbles. A fibre-optic hydrophone sensor mounted on the vessel chamber using a micromanipulator allowed pre-exposure targeting of the vessel to within 150 µm, and monitoring of acoustic cavitation emissions during exposures. Acoustic cavitation was also detected using changes in the ultrasound drive voltage and by detection of audible emissions using a submerged microphone. The suitability of this system for studying effects in the isolated vessel model has been demonstrated using a pilot study of 6 sham exposed and 18 high intensity focused ultrasound exposed vessels, with or without intraluminal contrast agent (SonoVue) within the vessels. (paper)

  9. Intraocular robotic interventional surgical system (IRISS): Mechanical design, evaluation, and master-slave manipulation.

    Science.gov (United States)

    Wilson, Jason T; Gerber, Matthew J; Prince, Stephen W; Chen, Cheng-Wei; Schwartz, Steven D; Hubschman, Jean-Pierre; Tsao, Tsu-Chin

    2018-02-01

    Since the advent of robotic-assisted surgery, the value of using robotic systems to assist in surgical procedures has been repeatedly demonstrated. However, existing technologies are unable to perform complete, multi-step procedures from start to finish. Many intraocular surgical steps continue to be manually performed. An intraocular robotic interventional surgical system (IRISS) capable of performing various intraocular surgical procedures was designed, fabricated, and evaluated. Methods were developed to evaluate the performance of the remote centers of motion (RCMs) using a stereo-camera setup and to assess the accuracy and precision of positioning the tool tip using an optical coherence tomography (OCT) system. The IRISS can simultaneously manipulate multiple surgical instruments, change between mounted tools using an onboard tool-change mechanism, and visualize the otherwise invisible RCMs to facilitate alignment of the RCM to the surgical incision. The accuracy of positioning the tool tip was measured to be 0.205±0.003 mm. The IRISS was evaluated by trained surgeons in a remote surgical theatre using post-mortem pig eyes and shown to be effective in completing many key steps in a variety of intraocular surgical procedures as well as being capable of performing an entire cataract extraction from start to finish. The IRISS represents a necessary step towards fully automated intraocular surgery and demonstrated accurate and precise master-slave manipulation for cataract removal and-through visual feedback-retinal vein cannulation. Copyright © 2017 John Wiley & Sons, Ltd.

  10. Left lower lobe sleeve lobectomy for lung cancer using the Da Vinci surgical system.

    Science.gov (United States)

    Zhao, Yandong; Jiao, Wenjie; Ren, Xiaoyang; Zhang, Liangdong; Qiu, Tong; Fu, Bo; Wang, Lei

    2016-04-12

    Despite the robotic surgery is widely applied, sleeve lobectomy for lung cancer using the Da Vinci surgical system is still less performed. We described a sleeve lobectomy for adenocarcinoma located at the left lower lobe using the Da Vinci surgical system. A case of 57-year old female referred to our hospital. Computed tomography scan showed an occupation located at the left lower lobe and adenocarcinoma project from the lobe bronchus was diagnosed by bronchoscope examination. A sleeve lobectomy was performed using the Da Vinci surgical system and the postoperative recovery was uneventful. Robotic thoracic surgery is feasible to perform sleeve lobectomy inspite of inadequate experience.

  11. High-frequency Doppler ultrasound transducer for the peripheral circulatory system

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Youngmin; Yang, Jeongwon; Kang, Uk; Kim, Guanghoon [Korea Electrotechnology Research Institute, Ansan (Korea, Republic of)

    2011-12-15

    A Doppler ultrasound transducer was designed and implemented to measure the blood flow velocity in tiny vessels near the skin of hands or feet. The geometric parameters of the transducer for defining the observation volume were derived and implemented with an acoustic window made of polystyrene. The observation volume designed in this study was located 6.5 mm from the transducer, which was comparable to the value predicted geometrically. The two-way insertion loss of the transducer was -11.3 dB on ultrasound frequency of 20 MHz, and the 3-dB bandwidth was approximately 2 MHz. In addition, the Doppler shift in the frequency measured by using a Doppler device composed of the transducer and a Doppler signal processing unit was proportional to the flow velocity generated by a homemade flowing system. Finally, we concluded that the transducer could be applied to measure the blood flow velocity in hands or feet.

  12. High-frequency Doppler ultrasound transducer for the peripheral circulatory system

    International Nuclear Information System (INIS)

    Bae, Youngmin; Yang, Jeongwon; Kang, Uk; Kim, Guanghoon

    2011-01-01

    A Doppler ultrasound transducer was designed and implemented to measure the blood flow velocity in tiny vessels near the skin of hands or feet. The geometric parameters of the transducer for defining the observation volume were derived and implemented with an acoustic window made of polystyrene. The observation volume designed in this study was located 6.5 mm from the transducer, which was comparable to the value predicted geometrically. The two-way insertion loss of the transducer was -11.3 dB on ultrasound frequency of 20 MHz, and the 3-dB bandwidth was approximately 2 MHz. In addition, the Doppler shift in the frequency measured by using a Doppler device composed of the transducer and a Doppler signal processing unit was proportional to the flow velocity generated by a homemade flowing system. Finally, we concluded that the transducer could be applied to measure the blood flow velocity in hands or feet.

  13. Development of ClearPEM-Sonic, a multimodal mammography system for PET and Ultrasound

    Science.gov (United States)

    Cucciati, G.; Auffray, E.; Bugalho, R.; Cao, L.; Di Vara, N.; Farina, F.; Felix, N.; Frisch, B.; Ghezzi, A.; Juhan, V.; Jun, D.; Lasaygues, P.; Lecoq, P.; Mensah, S.; Mundler, O.; Neves, J.; Paganoni, M.; Peter, J.; Pizzichemi, M.; Siles, P.; Silva, J. C.; Silva, R.; Tavernier, S.; Tessonnier, L.; Varela, J.

    2014-03-01

    ClearPEM-Sonic is an innovative imaging device specifically developed for breast cancer. The possibility to work in PEM-Ultrasound multimodality allows to obtain metabolic and morphological information increasing the specificity of the exam. The ClearPEM detector is developed to maximize the sensitivity and the spatial resolution as compared to Whole-Body PET scanners. It is coupled with a 3D ultrasound system, the SuperSonic Imagine Aixplorer that improves the specificity of the exam by providing a tissue elasticity map. This work describes the ClearPEM-Sonic project focusing on the technological developments it has required, the technical merits (and limits) and the first multimodal images acquired on a dedicated phantom. It finally presents selected clinical case studies that confirm the value of PEM information.

  14. Development of ClearPEM-Sonic, a multimodal mammography system for PET and Ultrasound

    International Nuclear Information System (INIS)

    Cucciati, G; Vara, N Di; Ghezzi, A; Paganoni, M; Pizzichemi, M; Auffray, E; Frisch, B; Lecoq, P; Bugalho, R; Neves, J; Cao, L; Peter, J; Farina, F; Felix, N; Juhan, V; Mundler, O; Siles, P; Jun, D; Lasaygues, P; Mensah, S

    2014-01-01

    ClearPEM-Sonic is an innovative imaging device specifically developed for breast cancer. The possibility to work in PEM-Ultrasound multimodality allows to obtain metabolic and morphological information increasing the specificity of the exam. The ClearPEM detector is developed to maximize the sensitivity and the spatial resolution as compared to Whole-Body PET scanners. It is coupled with a 3D ultrasound system, the SuperSonic Imagine Aixplorer that improves the specificity of the exam by providing a tissue elasticity map. This work describes the ClearPEM-Sonic project focusing on the technological developments it has required, the technical merits (and limits) and the first multimodal images acquired on a dedicated phantom. It finally presents selected clinical case studies that confirm the value of PEM information

  15. The sensitivity of schlieren systems for viewing ultrasound

    International Nuclear Information System (INIS)

    Hanstead, P.D.

    1976-01-01

    A novel set of simplifying assumptions makes computer prediction of schlieren sensitivity possible economically. Predictions correlate with experimental and published figures. Other means of improving sensitivity are given. A compact schlieren system giving binocular stereoscopic viewing is described

  16. A Wearable Transcranial Doppler Ultrasound Phased Array System.

    Science.gov (United States)

    Pietrangelo, Sabino J; Lee, Hae-Seung; Sodini, Charles G

    2018-01-01

     Practical deficiencies related to conventional transcranial Doppler (TCD) sonography have restricted its use and applicability. This work seeks to mitigate several such constraints through the development of a wearable, electronically steered TCD velocimetry system, which enables noninvasive measurement of cerebral blood flow velocity (CBFV) for monitoring applications with limited operator interaction. A highly-compact, discrete prototype system was designed and experimentally validated through flow phantom and preliminary human subject testing. The prototype system incorporates a custom two-dimensional transducer array and multi-channel transceiver electronics, thereby facilitating acoustic beamformation via phased array operation. Electronic steering of acoustic energy enables algorithmic system controls to map Doppler power throughout the tissue volume of interest and localize regions of maximal flow. Multi-focal reception permits dynamic vessel position tracking and simultaneous flow velocimetry over the time-course of monitoring. Experimental flow phantom testing yielded high correlation with concurrent flowmeter recordings across the expected range of physiological flow velocities. Doppler power mapping has been validated in both flow phantom and preliminary human subject testing, resulting in average vessel location mapping times testing. A wearable prototype CBFV measurement system capable of autonomous vessel search and tracking has been presented. Although flow phantom and preliminary human validation show promise, further human subject testing is necessary to compare velocimetry data against existing commercial TCD systems. Additional human subject testing must also verify acceptable vessel search and tracking performance under a variety of subject populations and motion dynamics-such as head movement and ambulation.

  17. Effect of high intensity ultrasound on the fermentation profile of Lactobacillus sakei in a meat model system.

    Science.gov (United States)

    Ojha, Kumari Shikha; Kerry, Joseph P; Alvarez, Carlos; Walsh, Des; Tiwari, Brijesh K

    2016-07-01

    The objective of this study was to investigate the efficacy of high intensity ultrasound on the fermentation profile of Lactobacillus sakei in a meat model system. Ultrasound power level (0-68.5 W) and sonication time (0-9 min) at 20 °C were assessed against the growth of L. sakei using a Microplate reader over a period of 24h. The L. sakei growth data showed a good fit with the Gompertz model (R(2)>0.90; SEfunctional food products can be tailored by selection of ultrasound processing parameters. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. A ring transducer system for medical ultrasound research.

    Science.gov (United States)

    Waag, Robert C; Fedewa, Russell J

    2006-10-01

    An ultrasonic ring transducer system has been developed for experimental studies of scattering and imaging. The transducer consists of 2048 rectangular elements with a 2.5-MHz center frequency, a 67% -6 dB bandwidth, and a 0.23-mm pitch arranged in a 150-mm-diameter ring with a 25-mm elevation. At the center frequency, the element size is 0.30lambda x 42lambda and the pitch is 0.38lambda. The system has 128 parallel transmit channels, 16 parallel receive channels, a 2048:128 transmit multiplexer, a 2048:16 receive multiplexer, independently programmable transmit waveforms with 8-bit resolution, and receive amplifiers with time variable gain independently programmable over a 40-dB range. Receive signals are sampled at 20 MHz with 12-bit resolution. Arbitrary transmit and receive apertures can be synthesized. Calibration software minimizes system nonidealities caused by noncircularity of the ring and element-to-element response differences. Application software enables the system to be used by specification of high-level parameters in control files from which low-level hardware-dependent parameters are derived by specialized code. Use of the system is illustrated by producing focused and steered beams, synthesizing a spatially limited plane wave, measuring angular scattering, and forming b-scan images.

  19. The state of the vegetative nervous system in patients with gonarthrosis for surgical treatment before and after surgical treatment

    Directory of Open Access Journals (Sweden)

    Karaseva T.lu.

    2012-12-01

    Full Text Available Aim. Analyzing the vegetative tensity of organism» functional systems before and after surgical treatment of elderly patients with metabolic-and-dystrophic gonarthrosis. Methods. The evaluation of vegetative homeostasis, reactivity of the vegetative nervous system by the data of variation pulsometry («REAN-POLY» RGPA-6/12, Taganrog in 60 patients with gonarthrosis at the age of 50-72 years and the disease duration — 9+1.5 years before and after surgical treatment: total tunnelization (Group I, tunnelization with osteotomy of leg bones for correction of limb biomechanical axis (Group II, treatment-and-diagnostic arthroscopy (Group III. Results. The reduction of the level of hypoxia tolerance and the decrease of the processes of general adaptation one month after surgery in Group I was registered in 40% of patients. As for patients of Group II, by the end of the period of fixation with the llizarov device — in 50%. As for those of Group III after arthroscopy — in 10% of patients. Among the patients whose 1С / 1С calculated parameter after surgical treatment was registered <1.0, its values were >10.0 before treatment in 70% of cases. At rest, marked vagotonia was registered with hypersympathicotonic reaction to orthotest, as well as with sharp decrease of the proportion of second-order slow waves while transition to standing position (VLF proportion <10.0%, thereby reflecting organism»s energy deficiency state. Conclusion. Preoperative examination. When VLF proportion after orthotest is registered <10.0%, such patients should be referred to risk group and prescribed in-depth examination. The index of centralization (1С dynamics for orthotest (1С test/1С rest is one of the criteria of functional recovery level for the particular patient: its increase points to the positive dynamics of restorative rehabilitative process, and the values <1.0 —to the negative one.

  20. Gynecomastia Classification for Surgical Management: A Systematic Review and Novel Classification System.

    Science.gov (United States)

    Waltho, Daniel; Hatchell, Alexandra; Thoma, Achilleas

    2017-03-01

    Gynecomastia is a common deformity of the male breast, where certain cases warrant surgical management. There are several surgical options, which vary depending on the breast characteristics. To guide surgical management, several classification systems for gynecomastia have been proposed. A systematic review was performed to (1) identify all classification systems for the surgical management of gynecomastia, and (2) determine the adequacy of these classification systems to appropriately categorize the condition for surgical decision-making. The search yielded 1012 articles, and 11 articles were included in the review. Eleven classification systems in total were ascertained, and a total of 10 unique features were identified: (1) breast size, (2) skin redundancy, (3) breast ptosis, (4) tissue predominance, (5) upper abdominal laxity, (6) breast tuberosity, (7) nipple malposition, (8) chest shape, (9) absence of sternal notch, and (10) breast skin elasticity. On average, classification systems included two or three of these features. Breast size and ptosis were the most commonly included features. Based on their review of the current classification systems, the authors believe the ideal classification system should be universal and cater to all causes of gynecomastia; be surgically useful and easy to use; and should include a comprehensive set of clinically appropriate patient-related features, such as breast size, breast ptosis, tissue predominance, and skin redundancy. None of the current classification systems appears to fulfill these criteria.

  1. A computerized tomography system for transcranial ultrasound imaging.

    Science.gov (United States)

    Tang, Sai Chun; Clement, Gregory T

    Hardware for tomographic imaging presents both challenge and opportunity for simplification when compared with traditional pulse-echo imaging systems. Specifically, point diffraction tomography does not require simultaneous powering of elements, in theory allowing just a single transmit channel and a single receive channel to be coupled with a switching or multiplexing network. In our ongoing work on transcranial imaging, we have developed a 512-channel system designed to transmit and/or receive a high voltage signal from/to arbitrary elements of an imaging array. The overall design follows a hierarchy of modules including a software interface, microcontroller, pulse generator, pulse amplifier, high-voltage power converter, switching mother board, switching daughter board, receiver amplifier, analog-to-digital converter, peak detector, memory, and USB communication. Two pulse amplifiers are included, each capable of producing up to 400Vpp via power MOSFETS. Switching is based around mechanical relays that allow passage of 200V, while still achieving switching times of under 2ms, with an operating frequency ranging from below 100kHz to 10MHz. The system is demonstrated through ex vivo human skulls using 1MHz transducers. The overall system design is applicable to planned human studies in transcranial image acquisition, and may have additional tomographic applications for other materials necessitating a high signal output.

  2. Simulation of advanced ultrasound systems using Field II

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2004-01-01

    impulse responses is explained. A simulation example for a synthetic aperture spread spectrum flow systems is described. It is shown how the advanced coded excitation can be set up, and how the simulation can be parallelized to reduce the simulation time from 17 months to 391 hours using a 32 CPU Linux...

  3. SARUS: A Synthetic Aperture Real-Time Ultrasound System

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Holten-Lund, Hans; Nilsson, Ronnie Thorup

    2013-01-01

    -resolution images/s. Both RF element data and beamformed data can be stored in the system for later storage and processing. The stored data can be transferred in parallel using the system’s sixty-four 1-Gbit Ethernet interfaces at a theoretical rate of 3.2 GB/s to a 144-core Linux cluster....

  4. Anatomy and Physiology. Module Set II: Major Body Systems. Teacher Edition [and] Student Edition. Surgical Technology.

    Science.gov (United States)

    Hilley, Robert

    This document, which is the second part of a two-part set of modules on anatomy and physiology for future surgical technicians, contains the teacher and student editions of an introduction to anatomy and physiology that consists of modules on the following body systems: integumentary system; skeletal system; muscular system; nervous system;…

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exams are also used to monitor the health and development of an embryo or fetus during pregnancy. See the ... can help to identify and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. ...

  6. Surgical smoke.

    Science.gov (United States)

    Fan, Joe King-Man; Chan, Fion Siu-Yin; Chu, Kent-Man

    2009-10-01

    Surgical smoke is the gaseous by-product formed during surgical procedures. Most surgeons, operating theatre staff and administrators are unaware of its potential health risks. Surgical smoke is produced by various surgical instruments including those used in electrocautery, lasers, ultrasonic scalpels, high speed drills, burrs and saws. The potential risks include carbon monoxide toxicity to the patient undergoing a laparoscopic operation, pulmonary fibrosis induced by non-viable particles, and transmission of infectious diseases like human papilloma virus. Cytotoxicity and mutagenicity are other concerns. Minimisation of the production of surgical smoke and modification of any evacuation systems are possible solutions. In general, a surgical mask can provide more than 90% protection to exposure to surgical smoke; however, in most circumstances it cannot provide air-tight protection to the user. An at least N95 grade or equivalent respirator offers the best protection against surgical smoke, but whether such protection is necessary is currently unknown.

  7. Wire in the Cable-Driven System of Surgical Robot

    Science.gov (United States)

    Wang, X. F.; Lv, N.; Mu, H. Z.; Xue, L. J.

    2017-07-01

    During the evolution of the surgical robot, cable plays an important role. It translates motion and force precisely from surgeon’s hand to the tool’s tips. In the paper, the vertical wires, the composition of cable, are mathematically modeled from a geometric point of view. The cable structure and tension are analyzed according to the characteristics of wire screw twist. The structural equations of the wires in different positions are derived for both non-bent cable and bent cable, respectively. The bending moment formula of bent cable is also obtained. This will help researchers find suitable cable and design more matched pulley.

  8. Toward a reduced-wire readout system for ultrasound imaging.

    Science.gov (United States)

    Lim, Jaemyung; Arkan, Evren F; Degertekin, F Levent; Ghovanloo, Maysam

    2014-01-01

    We present a system-on-a-chip (SoC) for use in high-frequency capacitive micromachined ultrasonic transducer (CMUT) imaging systems. This SoC consists of trans-impedance amplifiers (TIA), delay locked loop (DLL) based clock multiplier, quadrature sampler, and pulse width modulator (PWM). The SoC down converts RF echo signal to baseband by quadrature sampling which facilitates modulation. To send data through a 1.6 m wire in the catheter which has limited bandwidth and is vulnerable to noise, the SoC creates a pseudo-digital PWM signal which can be used for back telemetry or wireless readout of the RF data. In this implementation, using a 0.35-μm std. CMOS process, the TIA and single-to-differential (STD) converter had 45 MHz bandwidth, the quadrature sampler had 10.1 dB conversion gain, and the PWM had 5-bit ENoB. Preliminary results verified front-end functionality, and the power consumption of a TIA, STD, quadrature sampler, PWM, and clock multiplier was 26 mW from a 3 V supply.

  9. Early experience using the da Vinci Surgical System for the treatment of mediastinal tumors.

    Science.gov (United States)

    Kajiwara, Naohiro; Taira, Masahiro; Yoshida, Koichi; Hagiwara, Masaru; Kakihana, Masatoshi; Usuda, Jitsuo; Uchida, Osamu; Ohira, Tatsuo; Kawate, Norihiko; Ikeda, Norihiko

    2011-10-01

    The da Vinci Surgical System has been used in only a few cases for treating mediastinal tumors in Japan. Recently, we used the da Vinci Surgical System for various types of anterior and middle mediastinal tumors in clinical practice. We report our early experience using the da Vinci Surgical System. Seven patients gave written informed consent to undergo robotic surgery for mediastinal tumor dissection using the da Vinci Surgical System. We evaluated the safety and feasibility of this system for the surgical treatment of mediastinal tumors. Two specialists in thoracic surgery who are certified to use the da Vinci S Surgical System and another specialist acted as an assistant performed the tumor dissection. We were able to access difficult-to-reach areas, such as the mediastinum, safely. All the resected tumors were classified as benign tumors histologically. The average da Vinci setting time was 14.0 min, the average working time was 55.7 min, and the average overall operating time was 125.9 min. The learning curve for the da Vinci setup and manipulation time was short. Robotic surgery enables mediastinal tumor dissection in certain cases more safely and easily than conventional video-assisted thoracoscopic surgery and less invasively than open thoracotomy.

  10. Breast Ultrasound Examination with Video Monitor System: A Satisfaction Survey among Patients

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jung Kyu; Kim, Hyun Cheol; Yang, Dal Mo [East-West Neo Medical Center, Kyung-Hee University, Seoul (Korea, Republic of)

    2010-03-15

    The purpose of this study is to assess the patients satisfaction with a newly established video-monitor system and the associated basic items for performing breast ultrasound exams by conducting a survey among the patients. 349 patients were invited to take the survey and they had undergone breast ultrasound examination once during the 3 months after the monitor system has been introduced. The questionnaire was composed of 8 questions, 4 of which were about the basic items such as age, gender and the reason of their taking the breast ultrasound exam, their preference for the gender of the examiner and the desired length of time for the examination. The other 4 question were about their satisfaction with the video monitor. The patients were divided into two groups according to the purposes of taking the exams, which were screening or diagnostic purposes. The results were compared between these 2 groups. The satisfaction with the video monitor system was assessed by using a scoring system that ranged from 1 to 5. For the total patients, the screening group was composed of 124 patients and the diagnostic group was composed of 225. The reasons why the patients wanted to take the examinations in the diagnostic group varied. The questionnaire about the preference of the gender of the examiner showed that 81.5% in the screening group and 79.1% in the diagnostic group preferred a woman doctor. The required, suitable time for the breast ultrasound examination was 5 to 10 minutes or 10 to 15 minutes for about 70% of the patients. The mean satisfaction score for the video monitor system was as high as 3.95 point. The portion of patients in each group who answered over 3 points for their satisfaction with the monitor system was 88.7% and 94.2%, respectively. Our study showed that patients preferred 5-15 minutes for the length of the examination time and a female examiner. We also confirmed high patient satisfaction with the video monitor system

  11. Breast Ultrasound Examination with Video Monitor System: A Satisfaction Survey among Patients

    International Nuclear Information System (INIS)

    Ryu, Jung Kyu; Kim, Hyun Cheol; Yang, Dal Mo

    2010-01-01

    The purpose of this study is to assess the patients satisfaction with a newly established video-monitor system and the associated basic items for performing breast ultrasound exams by conducting a survey among the patients. 349 patients were invited to take the survey and they had undergone breast ultrasound examination once during the 3 months after the monitor system has been introduced. The questionnaire was composed of 8 questions, 4 of which were about the basic items such as age, gender and the reason of their taking the breast ultrasound exam, their preference for the gender of the examiner and the desired length of time for the examination. The other 4 question were about their satisfaction with the video monitor. The patients were divided into two groups according to the purposes of taking the exams, which were screening or diagnostic purposes. The results were compared between these 2 groups. The satisfaction with the video monitor system was assessed by using a scoring system that ranged from 1 to 5. For the total patients, the screening group was composed of 124 patients and the diagnostic group was composed of 225. The reasons why the patients wanted to take the examinations in the diagnostic group varied. The questionnaire about the preference of the gender of the examiner showed that 81.5% in the screening group and 79.1% in the diagnostic group preferred a woman doctor. The required, suitable time for the breast ultrasound examination was 5 to 10 minutes or 10 to 15 minutes for about 70% of the patients. The mean satisfaction score for the video monitor system was as high as 3.95 point. The portion of patients in each group who answered over 3 points for their satisfaction with the monitor system was 88.7% and 94.2%, respectively. Our study showed that patients preferred 5-15 minutes for the length of the examination time and a female examiner. We also confirmed high patient satisfaction with the video monitor system

  12. Virtual reality based surgical assistance and training system for long duration space missions.

    Science.gov (United States)

    Montgomery, K; Thonier, G; Stephanides, M; Schendel, S

    2001-01-01

    Access to medical care during long duration space missions is extremely important. Numerous unanticipated medical problems will need to be addressed promptly and efficiently. Although telemedicine provides a convenient tool for remote diagnosis and treatment, it is impractical due to the long delay between data transmission and reception to Earth. While a well-trained surgeon-internist-astronaut would be an essential addition to the crew, the vast number of potential medical problems necessitate instant access to computerized, skill-enhancing and diagnostic tools. A functional prototype of a virtual reality based surgical training and assistance tool was created at our center, using low-power, small, lightweight components that would be easy to transport on a space mission. The system consists of a tracked, head-mounted display, a computer system, and a number of tracked surgical instruments. The software provides a real-time surgical simulation system with integrated monitoring and information retrieval and a voice input/output subsystem. Initial medical content for the system has been created, comprising craniofacial, hand, inner ear, and general anatomy, as well as information on a number of surgical procedures and techniques. One surgical specialty in particular, microsurgery, was provided as a full simulation due to its long training requirements, significant impact on result due to experience, and likelihood for need. However, the system is easily adapted to realistically simulate a large number of other surgical procedures. By providing a general system for surgical simulation and assistance, the astronaut-surgeon can maintain their skills, acquire new specialty skills, and use tools for computer-based surgical planning and assistance to minimize overall crew and mission risk.

  13. Mammography and ultrasound in the evaluation of male breast disease

    Energy Technology Data Exchange (ETDEWEB)

    Munoz Carrasco, Rafaela; Alvarez Benito, Marina; Raya Povedano, Jose Luis [Hospital Universitario ' Reina Sofia' , Radiology Department, Cordoba (Spain); Munoz Gomariz, Elisa [Hospital Universitario ' Reina Sofia' , Support Unit for Research, Cordoba (Spain); Martinez Paredes, Maria [University of Cordoba, Radiology and Physical Medicine Area, Cordoba (Spain)

    2010-12-15

    To assess clinical variables that may be useful in differentiating gynaecomastia from carcinoma and to analyse the contribution of mammography and ultrasound to the evaluation of male breast disease. All men who underwent mammography and/or ultrasound between 1993 and 2006 in our hospital were retrospectively evaluated. Clinical characteristics in patients with gynaecomastia and those with carcinoma were compared. Radiological findings were classified according to the BI-RADS (Breast Imaging Reporting and Data System) criteria. The diagnostic performance of physical examination, mammography and ultrasound was determined and compared. A total of 628 patients with 518 mammograms and 423 ultrasounds were reviewed. The final diagnoses were: 19 carcinomas, 526 gynaecomastias, 84 other benign conditions and 25 normal. There were statistically significant differences in age, bilateral involvement, clinical presentation and physical examination between patients with carcinoma and those with gynaecomastia. The diagnostic performance of physical examination was lower than that of mammography and ultrasound (p < 0.05 for specificity). Mammography was the most sensitive (94.7%) and ultrasound the most specific (95.3%) for detection of malignancy (p > 0.05). We propose an algorithm for the use of mammography and ultrasound in men. Mammography and ultrasound, with a negative predictive value close to 100%, make it possible to avoid very many unnecessary surgical procedures in men. (orig.)

  14. Rotational multispectral fluorescence lifetime imaging and intravascular ultrasound: bimodal system for intravascular applications

    Science.gov (United States)

    Ma, Dinglong; Bec, Julien; Yankelevich, Diego R.; Gorpas, Dimitris; Fatakdawala, Hussain; Marcu, Laura

    2014-01-01

    Abstract. We report the development and validation of a hybrid intravascular diagnostic system combining multispectral fluorescence lifetime imaging (FLIm) and intravascular ultrasound (IVUS) for cardiovascular imaging applications. A prototype FLIm system based on fluorescence pulse sampling technique providing information on artery biochemical composition was integrated with a commercial IVUS system providing information on artery morphology. A customized 3-Fr bimodal catheter combining a rotational side-view fiberoptic and a 40-MHz IVUS transducer was constructed for sequential helical scanning (rotation and pullback) of tubular structures. Validation of this bimodal approach was conducted in pig heart coronary arteries. Spatial resolution, fluorescence detection efficiency, pulse broadening effect, and lifetime measurement variability of the FLIm system were systematically evaluated. Current results show that this system is capable of temporarily resolving the fluorescence emission simultaneously in multiple spectral channels in a single pullback sequence. Accurate measurements of fluorescence decay characteristics from arterial segments can be obtained rapidly (e.g., 20 mm in 5 s), and accurate co-registration of fluorescence and ultrasound features can be achieved. The current finding demonstrates the compatibility of FLIm instrumentation with in vivo clinical investigations and its potential to complement conventional IVUS during catheterization procedures. PMID:24898604

  15. Surgical PACS for the digital operating room. Systems engineering and specification of user requirements.

    Science.gov (United States)

    Korb, Werner; Bohn, Stefan; Burgert, Oliver; Dietz, Andreas; Jacobs, Stephan; Falk, Volkmar; Meixensberger, Jürgen; Strauss, Gero; Trantakis, Christos; Lemke, Heinz U

    2006-01-01

    For better integration of surgical assist systems into the operating room, a common communication and processing plattform that is based on the users needs is needed. The development of such a system, a Surgical Picture Aquisition and Communication System (S-PACS), according the systems engineering cycle is oulined in this paper. The first two steps (concept and specification) for the engineering of the S-PACS are discussed.A method for the systematic integration of the users needs', the Quality Function Deployment (QFD), is presented. The properties of QFD for the underlying problem and first results are discussed. Finally, this leads to a first definition of an S-PACS system.

  16. A multicenter hospital-based diagnosis study of automated breast ultrasound system in detecting breast cancer among Chinese women.

    Science.gov (United States)

    Zhang, Xi; Lin, Xi; Tan, Yanjuan; Zhu, Ying; Wang, Hui; Feng, Ruimei; Tang, Guoxue; Zhou, Xiang; Li, Anhua; Qiao, Youlin

    2018-04-01

    The automated breast ultrasound system (ABUS) is a potential method for breast cancer detection; however, its diagnostic performance remains unclear. We conducted a hospital-based multicenter diagnostic study to evaluate the clinical performance of the ABUS for breast cancer detection by comparing it to handheld ultrasound (HHUS) and mammography (MG). Eligible participants underwent HHUS and ABUS testing; women aged 40-69 years additionally underwent MG. Images were interpreted using the Breast Imaging Reporting and Data System (BI-RADS). Women in the BI-RADS categories 1-2 were considered negative. Women classified as BI-RADS 3 underwent magnetic resonance imaging to distinguish true- and false-negative results. Core aspiration or surgical biopsy was performed in women classified as BI-RADS 4-5, followed by a pathological diagnosis. Kappa values and agreement rates were calculated between ABUS, HHUS and MG. A total of 1,973 women were included in the final analysis. Of these, 1,353 (68.6%) and 620 (31.4%) were classified as BI-RADS categories 1-3 and 4-5, respectively. In the older age group, the agreement rate and Kappa value between the ABUS and HHUS were 94.0% and 0.860 (P<0.001), respectively; they were 89.2% and 0.735 (P<0.001) between the ABUS and MG, respectively. Regarding consistency between imaging and pathology results, 78.6% of women classified as BI-RADS 4-5 based on the ABUS were diagnosed with precancerous lesions or cancer; which was 7.2% higher than that of women based on HHUS. For BI-RADS 1-2, the false-negative rates of the ABUS and HHUS were almost identical and were much lower than those of MG. We observed a good diagnostic reliability for the ABUS. Considering its performance for breast cancer detection in women with high-density breasts and its lower operator dependence, the ABUS is a promising option for breast cancer detection in China.

  17. A review of the recommendations governing quality assurance of ultrasound systems used for guidance in prostate brachytherapy.

    Science.gov (United States)

    Doyle, Andrea Jane; King, Deirdre M; Browne, Jacinta E

    2017-12-01

    Ultrasound guided brachytherapy for the treatment of prostate cancer has become a routine treatment option, due to many benefits including patient recovery and dose localisation [1]; however it is not clear whether the standards which govern the image quality for these systems are adequate. Upon review of the recommended standards for ultrasound systems used in prostate brachytherapy procedures, the recommended tests do not appear to be specific to the clinical application of ultrasound guided prostate brachytherapy. Rather they are generic and similar to those recommended for other clinical applications such as general abdominal scanning [2]. Furthermore, there is growing evidence that these tests should be specific to the clinical application [3,4] in order to gain meaningful data about the performance of the system for the application, and also to detect clinically relevant changes in quality control results. An additional problem is that there are no clinically relevant test phantom recommended for the quality assurance of ultrasound systems used in prostate brachytherapy. The image quality for this application of ultrasound needs to be monitored to ensure consistent levels of confidence in the procedure. This paper reviews the currently recommended test guidelines and test phantoms for ultrasound systems used in prostate brachytherapy from the different standard bodies and professional organisations. A critical analysis of those tests which are most reflective of the imaging and guidance tasks undertaken in an ultrasound guided prostate brachytherapy procedure will also be presented to inform the design of a TRUS quality assurance protocol. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  18. Prehospital Ultrasound

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Full Text Available Ultrasound is a commonly used diagnostic tool in clinical conditions. With recent developments in technology, use of portable ultrasound devices has become feasible in prehospital settings. Many studies also proved the feasibility and accuracy of prehospital ultrasound. In this article, we focus on the use of prehospital ultrasound, with emphasis on trauma and chest ultrasound.

  19. MATLAB/Simulink Pulse-Echo Ultrasound System Simulator Based on Experimentally Validated Models.

    Science.gov (United States)

    Kim, Taehoon; Shin, Sangmin; Lee, Hyongmin; Lee, Hyunsook; Kim, Heewon; Shin, Eunhee; Kim, Suhwan

    2016-02-01

    A flexible clinical ultrasound system must operate with different transducers, which have characteristic impulse responses and widely varying impedances. The impulse response determines the shape of the high-voltage pulse that is transmitted and the specifications of the front-end electronics that receive the echo; the impedance determines the specification of the matching network through which the transducer is connected. System-level optimization of these subsystems requires accurate modeling of pulse-echo (two-way) response, which in turn demands a unified simulation of the ultrasonics and electronics. In this paper, this is realized by combining MATLAB/Simulink models of the high-voltage transmitter, the transmission interface, the acoustic subsystem which includes wave propagation and reflection, the receiving interface, and the front-end receiver. To demonstrate the effectiveness of our simulator, the models are experimentally validated by comparing the simulation results with the measured data from a commercial ultrasound system. This simulator could be used to quickly provide system-level feedback for an optimized tuning of electronic design parameters.

  20. [System design of small intellectualized ultrasound hyperthermia instrument in the LabVIEW environment].

    Science.gov (United States)

    Jiang, Feng; Bai, Jingfeng; Chen, Yazhu

    2005-08-01

    Small-scale intellectualized medical instrument has attracted great attention in the field of biomedical engineering, and LabVIEW (Laboratory Virtual Instrument Engineering Workbench) provides a convenient environment for this application due to its inherent advantages. The principle and system structure of the hyperthermia instrument are presented. Type T thermocouples are employed as thermotransducers, whose amplifier consists of two stages, providing built-in ice point compensation and thus improving work stability over temperature. Control signals produced by specially designed circuit drive the programmable counter/timer 8254 chip to generate PWM (Pulse width modulation) wave, which is used as ultrasound radiation energy control signal. Subroutine design topics such as inner-tissue real time feedback temperature control algorithm, water temperature control in the ultrasound applicator are also described. In the cancer tissue temperature control subroutine, the authors exert new improvments to PID (Proportional Integral Differential) algorithm according to the specific demands of the system and achieve strict temperature control to the target tissue region. The system design and PID algorithm improvement have experimentally proved to be reliable and excellent, meeting the requirements of the hyperthermia system.

  1. Multi-Channel RF System for MRI-Guided Transurethral Ultrasound Thermal Therapy

    Science.gov (United States)

    Yak, Nicolas; Asselin, Matthew; Chopra, Rajiv; Bronskill, Michael

    2009-04-01

    MRI-guided transurethral ultrasound thermal therapy is an approach to treating localized prostate cancer which targets precise deposition of thermal energy within a confined region of the gland. This treatment requires a system incorporating a heating applicator with multiple planar ultrasound transducers and associated RF electronics to control individual elements independently in order to achieve accurate 3D treatment. We report the design, construction, and characterization of a prototype multi-channel system capable of controlling 16 independent RF signals for a 16-element heating applicator. The main components are a control computer, microcontroller, and a 16-channel signal generator with 16 amplifiers, each incorporating a low-pass filter and transmitted/reflected power detection circuit. Each channel can deliver from 0.5 to 10 W of electrical power and good linearity from 3 to 12 MHz. Harmonic RF signals near the Larmor frequency of a 1.5 T MRI were measured to be below -30 dBm and heating experiments within the 1.5 T MR system showed no significant decrease in SNR of the temperature images. The frequency and power for all 16 channels could be changed in less than 250 ms, which was sufficiently rapid for proper performance of the control algorithms. A common backplane design was chosen which enabled an inexpensive, modular approach for each channel resulting in an overall system with minimal footprint.

  2. Evolution of Robot-assisted ultrasound-guided breast biopsy systems

    Directory of Open Access Journals (Sweden)

    Mustafa Z. Mahmoud

    2018-01-01

    Full Text Available Robot-assisted ultrasound-guided breast biopsy combines ultrasound (US imaging with a robotic system for medical interventions. This study was designed to provide a literature review of a robotic US-guided breast biopsy system to delineate its efficacious impact on current medical practice. In addition, the strengths and limitations of this approach were also addressed. Articles published in the English language between 2000 and 2016 were appraised in this review. A wide range of systems that bind robotics with US imaging and guided breast biopsy were examined in this article. The fundamental safety and real-time imaging capabilities of US, together with the accuracy and maneuverability of robotic devices, is clearly an effective association with unmatched capabilities. Numerous experimental systems have obvious benefits over old-fashioned techniques, and the future of robot-assisted US-guided breast biopsy will be characterized by increasing levels of automation, and they hold tremendous possibility to impact doctor achievement, patient recovery, and clinical management.

  3. Three-dimensional ultrasound image-guided robotic system for accurate microwave coagulation of malignant liver tumours.

    Science.gov (United States)

    Xu, Jing; Jia, Zhen-zhong; Song, Zhang-jun; Yang, Xiang-dong; Chen, Ken; Liang, Ping

    2010-09-01

    The further application of conventional ultrasound (US) image-guided microwave (MW) ablation of liver cancer is often limited by two-dimensional (2D) imaging, inaccurate needle placement and the resulting skill requirement. The three-dimensional (3D) image-guided robotic-assisted system provides an appealing alternative option, enabling the physician to perform consistent, accurate therapy with improved treatment effectiveness. Our robotic system is constructed by integrating an imaging module, a needle-driven robot, a MW thermal field simulation module, and surgical navigation software in a practical and user-friendly manner. The robot executes precise needle placement based on the 3D model reconstructed from freehand-tracked 2D B-scans. A qualitative slice guidance method for fine registration is introduced to reduce the placement error caused by target motion. By incorporating the 3D MW specific absorption rate (SAR) model into the heat transfer equation, the MW thermal field simulation module determines the MW power level and the coagulation time for improved ablation therapy. Two types of wrists are developed for the robot: a 'remote centre of motion' (RCM) wrist and a non-RCM wrist, which is preferred in real applications. The needle placement accuracies were robot with the RCM wrist was improved to 1.6 +/- 1.0 mm when real-time 2D US feedback was used in the artificial-tissue phantom experiment. By using the slice guidance method, the robot with the non-RCM wrist achieved accuracy of 1.8 +/- 0.9 mm in the ex vivo experiment; even target motion was introduced. In the thermal field experiment, a 5.6% relative mean error was observed between the experimental coagulated neurosis volume and the simulation result. The proposed robotic system holds promise to enhance the clinical performance of percutaneous MW ablation of malignant liver tumours. Copyright 2010 John Wiley & Sons, Ltd.

  4. Development and validation of a surgical-pathologic staging and scoring system for cervical cancer.

    Science.gov (United States)

    Li, Shuang; Li, Xiong; Zhang, Yuan; Zhou, Hang; Tang, Fangxu; Jia, Yao; Hu, Ting; Sun, Haiying; Yang, Ru; Chen, Yile; Cheng, Xiaodong; Lv, Weiguo; Wu, Li; Zhou, Jin; Wang, Shaoshuai; Huang, Kecheng; Wang, Lin; Yao, Yuan; Yang, Qifeng; Yang, Xingsheng; Zhang, Qinghua; Han, Xiaobing; Lin, Zhongqiu; Xing, Hui; Qu, Pengpeng; Cai, Hongbing; Song, Xiaojie; Tian, Xiaoyu; Shen, Jian; Xi, Ling; Li, Kezhen; Deng, Dongrui; Wang, Hui; Wang, Changyu; Wu, Mingfu; Zhu, Tao; Chen, Gang; Gao, Qinglei; Wang, Shixuan; Hu, Junbo; Kong, Beihua; Xie, Xing; Ma, Ding

    2016-04-12

    Most cervical cancer patients worldwide receive surgical treatments, and yet the current International Federation of Gynecology and Obstetrics (FIGO) staging system do not consider surgical-pathologic data. We propose a more comprehensive and prognostically valuable surgical-pathologic staging and scoring system (SPSs). Records from 4,220 eligible cervical cancer cases (Cohort 1) were screened for surgical-pathologic risk factors. We constructed a surgical-pathologic staging and SPSs, which was subsequently validated in a prospective study of 1,104 cervical cancer patients (Cohort 2). In Cohort 1, seven independent risk factors were associated with patient outcome: lymph node metastasis (LNM), parametrial involvement, histological type, grade, tumor size, stromal invasion, and lymph-vascular space invasion (LVSI). The FIGO staging system was revised and expanded into a surgical-pathologic staging system by including additional criteria of LNM, stromal invasion, and LVSI. LNM was subdivided into three categories based on number and location of metastases. Inclusion of all seven prognostic risk factors improves practical applicability. Patients were stratified into three SPSs risk categories: zero-, low-, and high-score with scores of 0, 1 to 3, and ≥4 (P=1.08E-45; P=6.15E-55). In Cohort 2, 5-year overall survival (OS) and disease-free survival (DFS) outcomes decreased with increased SPSs scores (P=9.04E-15; P=3.23E-16), validating the approach. Surgical-pathologic staging and SPSs show greater homogeneity and discriminatory utility than FIGO staging. Surgical-pathologic staging and SPSs improve characterization of tumor severity and disease invasion, which may more accurately predict outcome and guide postoperative therapy.

  5. Early clinical experience with the da Vinci Xi Surgical System in general surgery.

    Science.gov (United States)

    Hagen, Monika E; Jung, Minoa K; Ris, Frederic; Fakhro, Jassim; Buchs, Nicolas C; Buehler, Leo; Morel, Philippe

    2017-09-01

    The da Vinci Xi Surgical System (Intuitive Surgical Inc., Sunnyvale, CA, USA) has been released in 2014 to facilitate minimally invasive surgery. Novel features are targeted towards facilitating complex multi-quadrant procedures, but data is scarce so far. Perioperative data of patients who underwent robotic general surgery with the da Vinci Xi system within the first 6 month after installation were collected and analyzed. The gastric bypass procedures performed with the da Vinci Xi Surgical System were compared to an equal amount of the last procedures with the da Vinci Si Surgical System. Thirty-one foregut (28 Roux-en-Y gastric bypasses), 6 colorectal procedures and 1 revisional biliary procedure were performed. The mean operating room (OR) time was 221.8 (±69.0) minutes for gastric bypasses and 306.5 (±48.8) for colorectal procedures with mean docking time of 9.4 (±3.8) minutes. The gastric bypass procedure was transitioned from a hybrid to a fully robotic approach. In comparison to the last 28 gastric bypass procedures performed with the da Vinci Si Surgical System, the OR time was comparable (226.9 versus 230.6 min, p = 0.8094), but the docking time significantly longer with the da Vinci Xi Surgical System (8.5 versus 6.1 min, p = 0.0415). All colorectal procedures were performed with a single robotic docking. No intraoperative and two postoperative complications occurred. The da Vinci Xi might facilitate single-setups of totally robotic gastric bypass and colorectal surgeries. However, further comparable research is needed to clearly determine the significance of this latest version of the da Vinci Surgical System.

  6. Processing system of jaws tomograms for pathology identification and surgical guide modeling

    Energy Technology Data Exchange (ETDEWEB)

    Putrik, M. B., E-mail: pmb-88@mail.ru; Ivanov, V. Yu. [Ural Federal University named after the first President of Russia B.N. Yeltsin, Yekaterinburg (Russian Federation); Lavrentyeva, Yu. E. [Private dental clinic «Uraldent», Yekaterinburg (Russian Federation)

    2015-11-17

    The aim of the study is to create an image processing system, which allows dentists to find pathological resorption and to build surgical guide surface automatically. X-rays images of jaws from cone beam tomography or spiral computed tomography are the initial data for processing. One patient’s examination always includes up to 600 images (or tomograms), that’s why the development of processing system for fast automation search of pathologies is necessary. X-rays images can be useful not for only illness diagnostic but for treatment planning too. We have studied the case of dental implantation – for successful surgical manipulations surgical guides are used. We have created a processing system that automatically builds jaw and teeth boundaries on the x-ray image. After this step, obtained teeth boundaries used for surgical guide surface modeling and jaw boundaries limit the area for further pathologies search. Criterion for the presence of pathological resorption zones inside the limited area is based on statistical investigation. After described actions, it is possible to manufacture surgical guide using 3D printer and apply it in surgical operation.

  7. Processing system of jaws tomograms for pathology identification and surgical guide modeling

    International Nuclear Information System (INIS)

    Putrik, M. B.; Ivanov, V. Yu.; Lavrentyeva, Yu. E.

    2015-01-01

    The aim of the study is to create an image processing system, which allows dentists to find pathological resorption and to build surgical guide surface automatically. X-rays images of jaws from cone beam tomography or spiral computed tomography are the initial data for processing. One patient’s examination always includes up to 600 images (or tomograms), that’s why the development of processing system for fast automation search of pathologies is necessary. X-rays images can be useful not for only illness diagnostic but for treatment planning too. We have studied the case of dental implantation – for successful surgical manipulations surgical guides are used. We have created a processing system that automatically builds jaw and teeth boundaries on the x-ray image. After this step, obtained teeth boundaries used for surgical guide surface modeling and jaw boundaries limit the area for further pathologies search. Criterion for the presence of pathological resorption zones inside the limited area is based on statistical investigation. After described actions, it is possible to manufacture surgical guide using 3D printer and apply it in surgical operation

  8. Do Robotic Surgical Systems Improve Profit Margins? A Cross-Sectional Analysis of California Hospitals.

    Science.gov (United States)

    Shih, Ya-Chen Tina; Shen, Chan; Hu, Jim C

    2017-09-01

    The aim of this study was to examine the association between ownership of robotic surgical systems and hospital profit margins. This study used hospital annual utilization data, annual financial data, and discharge data for year 2011 from the California Office of Statewide Health Planning and Development. We first performed bivariate analysis to compare mean profit margin by hospital and market characteristics and to examine whether these characteristics differed between hospitals that had one or more robotic surgical systems in 2011 and those that did not. We applied the t test and the F test to compare mean profit margin between two groups and among three or more groups, respectively. We then conducted multilevel logistic regression to determine the association between ownership of robotic surgical systems and having a positive profit margin after controlling for other hospital and market characteristics and accounting for possible correlation among hospitals located within the same market. The study sample included 167 California hospitals with valid financial information. Hospitals with robotic surgical systems tended to report more favorable profit margins. However, multilevel logistic regression showed that this relationship (an association, not causality) became only marginally significant (odds ratio [OR] = 6.2; P = 0.053) after controlling for other hospital characteristics, such as ownership type, teaching status, bed size, and surgical volumes, and market characteristics, such as total number of robotic surgical systems owned by other hospitals in the same market area. As robotic surgical systems become widely disseminated, hospital decision makers should carefully evaluate the financial and clinical implications before making a capital investment in this technology. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  9. Ultrasound-controlled neuronavigator-guided brain surgery.

    Science.gov (United States)

    Koivukangas, J; Louhisalmi, Y; Alakuijala, J; Oikarinen, J

    1993-07-01

    The development of a unique neurosurgical navigator is described and a preliminary series of seven cases of intracerebral lesions approached with the assistance of this neuronavigation system under ultrasound control is presented. The clinical series included five low-grade astrocytomas, one chronic intracerebral hematoma, and one porencephalic cyst. Management procedures included biopsy in all cases, drainage of the hematoma, and endoscopy and fenestration for the cyst. The features of the neuronavigation system are interactive reconstructions of preoperative computerized tomography and magnetic resonance imaging data, corresponding intraoperative ultrasound images, versatility of the interchangeable end-effector instruments, graphic presentation of instruments on the reconstructed images, and voice control of the system. The principle of a common axis in the reconstructed images served to align the navigational pointer, biopsy guide, endoscope guide, ultrasound transducer, and surgical microscope to the brain anatomy. Intraoperative ultrasound imaging helped to verify the accuracy of the neuronavigator and check the results of the procedures. The arm of the neuronavigation system served as a holder for instruments, such as the biopsy guide, endoscope guide, and ultrasound transducer, in addition to functioning as a navigational pointer. Also, the surgical microscope was aligned with the neuronavigator for inspection and biopsy of the hematoma capsule to rule out tumor etiology. Voice control freed the neurosurgeon from manual exercises during start-up and calibration of the system.

  10. Animal study assessing safety of an acoustic coupling fluid that holds the potential to avoid surgically induced artifacts in 3D ultrasound guided operations

    International Nuclear Information System (INIS)

    Jakola, Asgeir S; Jørgensen, Arve; Selbekk, Tormod; Michler, Ralf-Peter; Solheim, Ole; Torp, Sverre H; Sagberg, Lisa M; Aadahl, Petter; Unsgård, Geirmund

    2014-01-01

    Use of ultrasound in brain tumor surgery is common. The difference in attenuation between brain and isotonic saline may cause artifacts that degrade the ultrasound images, potentially affecting resection grades and safety. Our research group has developed an acoustic coupling fluid that attenuates ultrasound energy like the normal brain. We aimed to test in animals if the newly developed acoustic coupling fluid may have harmful effects. Eight rats were included for intraparenchymal injection into the brain, and if no adverse reactions were detected, 6 pigs were to be included with injection of the coupling fluid into the subarachnoid space. Animal behavior, EEG registrations, histopathology and immunohistochemistry were used in assessment. In total, 14 animals were included, 8 rats and 6 pigs. We did not detect any clinical adverse effects, seizure activity on EEG or histopathological signs of tissue damage. The novel acoustic coupling fluid intended for brain tumor surgery appears safe in rats and pigs under the tested circumstances

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a pelvic ultrasound examination. Doppler ultrasound , also called color Doppler ultrasonography, is a special ultrasound technique that ... and processes the sounds and creates graphs or color pictures that represent the flow of blood through ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are ... Ultrasound page for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: pelvic ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently ... pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Obstetrical Ultrasound page for more information . Ultrasound examinations can help diagnose symptoms experienced by women such as: ...

  15. TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

    International Nuclear Information System (INIS)

    Garra, B.

    2016-01-01

    Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging

  16. TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

    Energy Technology Data Exchange (ETDEWEB)

    Garra, B. [FDA, Silver Spring, MD (United States)

    2016-06-15

    Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging

  17. Implementation of a virtual vascular clinic with point-of-care ultrasound in an integrated health care system.

    Science.gov (United States)

    Lin, Judith C; Crutchfield, Janelle M; Zurawski, Dana K; Stevens, Courtney

    2018-02-01

    Using secured videoconferencing technologies, telemedicine may replace traditional clinic visits, save patients' time and travel, and improve use of limited surgeon and facility resources. We report our initial experience of the remote clinical encounter (RCE) by evaluating vascular surgery patients. In this proof-of-concept pilot study, we conducted telemedicine evaluations of vascular patients at a tertiary care institution from October 2015 to August 2016. Patients were offered synchronous virtual visits from a surgical provider in lieu of an in-person visit. We used Skype for Business (Microsoft, Redmond, Wash) over secured networks for patient-provider interaction, clinical data entry in the Epic electronic medical record (Epic Systems Corporation, Verona, Wisc) for documentation, and established satellite facilities with existing vascular laboratories for imaging and laboratory testing. We evaluated feasibility, demographics, encounter type, and satisfaction of the patient through web-based questionnaires. During a 10-month period, 41 women and 14 men with an average age of 57 years (range, 29-79 years) underwent 82 RCEs. There were 43 white (78.1%), 9 black (16.3%), 1 Asian (1.8%), and 2 Middle Eastern (3.6%) patients. Diagnoses included both arterial (aneurysm, carotid, and occlusive disease) and venous (deep venous thrombosis and varicose vein) disease. Among the 82 RCEs, visit types included 15 new patients, 30 postoperative visits, and 37 follow-up visits. Ultrasound imaging was performed in conjunction with the RCE in 74 patients (90.2%). Most patients (57%) had multiple RCEs during the study period. All 55 patients responded to the satisfaction questionnaire; 91% stated that they would highly recommend a virtual physician encounter to a friend or colleague, and all of the respondents found their encounter more convenient than having a traditional office visit. All patients thought that they were able to communicate clearly with the provider, and

  18. Multi-processor system for real-time deconvolution and flow estimation in medical ultrasound

    DEFF Research Database (Denmark)

    Jensen, Jesper Lomborg; Jensen, Jørgen Arendt; Stetson, Paul F.

    1996-01-01

    of the algorithms. Many of the algorithms can only be properly evaluated in a clinical setting with real-time processing, which generally cannot be done with conventional equipment. This paper therefore presents a multi-processor system capable of performing 1.2 billion floating point operations per second on RF...... filter is used with a second time-reversed recursive estimation step. Here it is necessary to perform about 70 arithmetic operations per RF sample or about 1 billion operations per second for real-time deconvolution. Furthermore, these have to be floating point operations due to the adaptive nature...... interfaced to our previously-developed real-time sampling system that can acquire RF data at a rate of 20 MHz and simultaneously transmit the data at 20 MHz to the processing system via several parallel channels. These two systems can, thus, perform real-time processing of ultrasound data. The advantage...

  19. Interlaced photoacoustic and ultrasound imaging system with real-time coregistration for ovarian tissue characterization

    Science.gov (United States)

    Alqasemi, Umar; Li, Hai; Yuan, Guangqian; Kumavor, Patrick; Zanganeh, Saeid; Zhu, Quing

    2014-07-01

    Coregistered ultrasound (US) and photoacoustic imaging are emerging techniques for mapping the echogenic anatomical structure of tissue and its corresponding optical absorption. We report a 128-channel imaging system with real-time coregistration of the two modalities, which provides up to 15 coregistered frames per second limited by the laser pulse repetition rate. In addition, the system integrates a compact transvaginal imaging probe with a custom-designed fiber optic assembly for in vivo detection and characterization of human ovarian tissue. We present the coregistered US and photoacoustic imaging system structure, the optimal design of the PC interfacing software, and the reconfigurable field programmable gate array operation and optimization. Phantom experiments of system lateral resolution and axial sensitivity evaluation, examples of the real-time scanning of a tumor-bearing mouse, and ex vivo human ovaries studies are demonstrated.

  20. Prospective validation of a surgical complications grading system in a cohort of 2114 patients.

    Science.gov (United States)

    Mazeh, Haggi; Cohen, Oded; Mizrahi, Ido; Hamburger, Tamar; Stojadinovic, Alexander; Abu-Wasel, Bassam; Alaiyan, Bilal; Freund, Herbert R; Eid, Ahmed; Nissan, Aviram

    2014-05-01

    We recently reported a grading system for surgical complications. This system proved to have a high sensitivity for recording minor but meaningful complications prolonging hospital stay in patients after colorectal surgery. We aimed to prospectively validate the complication grading system in a general surgery department over 1 year. All surgical procedures and related complications were prospectively recorded between January 1st and December 31st, 2009. Surgical complications were graded on a severity scale of 1-5. The system classifies short-term outcome by grade emphasizing intensity of therapy required for treatment of the defined complication. During the study period, 2114 patients underwent surgery. Elective and oncological surgeries were performed in 1606 (76%) and 465 (22%) patients, respectively. There were 422 surgical complications in 304 (14%) patients (Grade 1/2: 203 [67%]; Grade 3/4: 90 [29%]; Grade 5: 11 [4%]). Median length of stay correlated significantly with complication severity: 2.3 d for no complication, 6.2 and 11.8 d for Grades 1/2 and 3/4, respectively (P 2 (OR 2.07, P Grade (OR 1.85, P = 0.001), oncological (OR 2.82, P 120 min (OR 2.08, P grading surgical complications permits standardized reporting of surgical morbidity according to the severity of impact. Prospective validation of this system supports its use in a general surgery setting as a tool for surgical outcome assessment and quality assurance. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Research of the master-slave robot surgical system with the function of force feedback.

    Science.gov (United States)

    Shi, Yunyong; Zhou, Chaozheng; Xie, Le; Chen, Yongjun; Jiang, Jun; Zhang, Zhenfeng; Deng, Ze

    2017-12-01

    Surgical robots lack force feedback, which may lead to operation errors. In order to improve surgical outcomes, this research developed a new master-slave surgical robot, which was designed with an integrated force sensor. The new structure designed for the master-slave robot employs a force feedback mechanism. A six-dimensional force sensor was mounted on the tip of the slave robot's actuator. Sliding model control was adopted to control the slave robot. According to the movement of the master system manipulated by the surgeon, the slave's movement and the force feedback function were validated. The motion was completed, the standard deviation was calculated, and the force data were detected. Hence, force feedback was realized in the experiment. The surgical robot can help surgeons to complete trajectory motions with haptic sensation. Copyright © 2017 John Wiley & Sons, Ltd.

  2. Effect of sensory substitution on suture-manipulation forces for robotic surgical systems.

    Science.gov (United States)

    Kitagawa, Masaya; Dokko, Daniell; Okamura, Allison M; Yuh, David D

    2005-01-01

    Direct haptic (force or tactile) feedback is not yet available in commercial robotic surgical systems. Previous work by our group and others suggests that haptic feedback might significantly enhance the execution of surgical tasks requiring fine suture manipulation, specifically those encountered in cardiothoracic surgery. We studied the effects of substituting direct haptic feedback with visual and auditory cues to provide the operating surgeon with a representation of the forces he or she is applying with robotic telemanipulators. Using the robotic da Vinci surgical system (Intuitive Surgical, Inc, Sunnyvale, Calif), we compared applied forces during a standardized surgical knot-tying task under 4 different sensory-substitution scenarios: no feedback, auditory feedback, visual feedback, and combined auditory-visual feedback. The forces applied with these sensory-substitution modes more closely approximate suture tensions achieved under ideal haptic conditions (ie, hand ties) than forces applied without such sensory feedback. The consistency of applied forces during robot-assisted suture tying aided by visual feedback or combined auditory-visual feedback sensory substitution is superior to that achieved with hand ties. Robot-assisted ties aided with auditory feedback revealed levels of consistency that were generally equivalent or superior to those attained with hand ties. Visual feedback and auditory feedback improve the consistency of robotically applied forces. Sensory substitution, in the form of visual feedback, auditory feedback, or both, confers quantifiable advantages in applied force accuracy and consistency during the performance of a simple surgical task.

  3. Patient-specific system for prognosis of surgical treatment outcomes of human cardiovascular system

    Science.gov (United States)

    Golyadkina, Anastasiya A.; Kalinin, Aleksey A.; Kirillova, Irina V.; Kossovich, Elena L.; Kossovich, Leonid Y.; Menishova, Liyana R.; Polienko, Asel V.

    2015-03-01

    Object of study: Improvement of life quality of patients with high stroke risk ia the main goal for development of system for patient-specific modeling of cardiovascular system. This work is dedicated at increase of safety outcomes for surgical treatment of brain blood supply alterations. The objects of study are common carotid artery, internal and external carotid arteries and bulb. Methods: We estimated mechanical properties of carotid arteries tissues and patching materials utilized at angioplasty. We studied angioarchitecture features of arteries. We developed and clinically adapted computer biomechanical models, which are characterized by geometrical, physical and mechanical similarity with carotid artery in norm and with pathology (atherosclerosis, pathological tortuosity, and their combination). Results: Collaboration of practicing cardiovascular surgeons and specialists in the area of Mathematics and Mechanics allowed to successfully conduct finite-element modeling of surgical treatment taking into account various features of operation techniques and patching materials for a specific patient. Numerical experiment allowed to reveal factors leading to brain blood supply decrease and atherosclerosis development. Modeling of carotid artery reconstruction surgery for a specific patient on the basis of the constructed biomechanical model demonstrated the possibility of its application in clinical practice at approximation of numerical experiment to the real conditions.

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: ...

  5. A Google Glass navigation system for ultrasound and fluorescence dual-mode image-guided surgery

    Science.gov (United States)

    Zhang, Zeshu; Pei, Jing; Wang, Dong; Hu, Chuanzhen; Ye, Jian; Gan, Qi; Liu, Peng; Yue, Jian; Wang, Benzhong; Shao, Pengfei; Povoski, Stephen P.; Martin, Edward W.; Yilmaz, Alper; Tweedle, Michael F.; Xu, Ronald X.

    2016-03-01

    Surgical resection remains the primary curative intervention for cancer treatment. However, the occurrence of a residual tumor after resection is very common, leading to the recurrence of the disease and the need for re-resection. We develop a surgical Google Glass navigation system that combines near infrared fluorescent imaging and ultrasonography for intraoperative detection of sites of tumor and assessment of surgical resection boundaries, well as for guiding sentinel lymph node (SLN) mapping and biopsy. The system consists of a monochromatic CCD camera, a computer, a Google Glass wearable headset, an ultrasonic machine and an array of LED light sources. All the above components, except the Google Glass, are connected to a host computer by a USB or HDMI port. Wireless connection is established between the glass and the host computer for image acquisition and data transport tasks. A control program is written in C++ to call OpenCV functions for image calibration, processing and display. The technical feasibility of the system is tested in both tumor simulating phantoms and in a human subject. When the system is used for simulated phantom resection tasks, the tumor boundaries, invisible to the naked eye, can be clearly visualized with the surgical Google Glass navigation system. This system has also been used in an IRB approved protocol in a single patient during SLN mapping and biopsy in the First Affiliated Hospital of Anhui Medical University, demonstrating the ability to successfully localize and resect all apparent SLNs. In summary, our tumor simulating phantom and human subject studies have demonstrated the technical feasibility of successfully using the proposed goggle navigation system during cancer surgery.

  6. High-intensity ultrasound production of Maillard reaction flavor compounds in a cysteine-xylose model system.

    Science.gov (United States)

    Ong, Olivia X H; Seow, Yi-Xin; Ong, Peter K C; Zhou, Weibiao

    2015-09-01

    Application of high intensity ultrasound has shown potential in the production of Maillard reaction odor-active flavor compounds in model systems. The impact of initial pH, sonication duration, and ultrasound intensity on the production of Maillard reaction products (MRPs) by ultrasound processing in a cysteine-xylose model system were evaluated using Response Surface Methodology (RSM) with a modified mathematical model. Generation of selected MRPs, 2-methylthiophene and tetramethyl pyrazine, was optimal at an initial pH of 6.00, accompanied with 78.1 min of processing at an ultrasound intensity of 19.8 W cm(-2). However, identification of volatiles using gas chromatography-mass spectrometry (GC/MS) revealed that ultrasound-assisted Maillard reactions generated fewer sulfur-containing volatile flavor compounds as compared to conventional heat treatment of the model system. Likely reasons for this difference in flavor profile include the expulsion of H2S due to ultrasonic degassing and inefficient transmission of ultrasonic energy. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Clinical effectiveness and cost-effectiveness of endobronchial and endoscopic ultrasound relative to surgical staging in potentially resectable lung cancer: results from the ASTER randomised controlled trial

    NARCIS (Netherlands)

    Sharples, L. D.; Jackson, C.; Wheaton, E.; Griffith, G.; Annema, J. T.; Dooms, C.; Tournoy, K. G.; Deschepper, E.; Hughes, V.; Magee, L.; Buxton, M.; Rintoul, R. C.

    2012-01-01

    To assess the clinical effectiveness and cost-effectiveness of endosonography (followed by surgical staging if endosonography was negative), compared with standard surgical staging alone, in patients with non-small cell lung cancer (NSCLC) who are otherwise candidates for surgery with curative

  8. The Use of the OMERACT Ultrasound Tenosynovitis Scoring System in Multicenter Clinical Trials.

    Science.gov (United States)

    Ammitzbøll-Danielsen, Mads; Østergaard, Mikkel; Naredo, Esperanza; Iagnocco, Annamaria; Möller, Ingrid; D'Agostino, Maria-Antonietta; Gandjbakhch, Frédérique; Terslev, Lene

    2018-02-01

    To test the sensitivity to change of the Outcome Measures in Rheumatology Clinical Trials (OMERACT) ultrasound (US) scoring system for tenosynovitis when applied in a multicenter design. RA patients with US-verified tenosynovitis were recruited when scheduled for treatment intensification. Tenosynovitis was assessed at baseline, and 3 and 6 months followup, using the semiquantitative OMERACT scoring system. Expressed in median (25th; 75th percentiles), the overall greyscale and Doppler score decreased significantly from baseline at 4 (2; 7) and 3 (2; 6), to 6 months at 2 (0; 3) and 0 (0; 1, p The OMERACT US scoring system for tenosynovitis showed high responsiveness, supporting its use for diagnosing and monitoring tenosynovitis in multicenter trials.

  9. Gene delivery systems by the combination of lipid bubbles and ultrasound.

    Science.gov (United States)

    Negishi, Yoichi; Endo-Takahashi, Yoko; Maruyama, Kazuo

    2016-11-28

    Gene therapy is promising for the treatment of many diseases including cancers and genetic diseases. From the viewpoint of safety, ultrasound (US)-mediated gene delivery with nano/ microbubbles was recently developed as a novel non-viral vector system. US-mediated gene delivery using nano/microbubbles are able to produce transient changes in the permeability of the cell membrane after US-induced cavitation while reducing cellular damage and enables the tissue-specific or the site-specific intracellular delivery of gene both in vitro and in vivo. We have recently developed novel lipid nanobubbles (Lipid Bubbles). These nanobubbles can also be used to enhance the efficacy of the US-mediated genes (plasmid DNA, siRNA, and miRNA etc.) delivery. In this review, we describe US-mediated delivery systems combined with nano/microbubbles and discuss their feasibility as non-viral vector systems.

  10. Design and implementation of a PC-based image-guided surgical system.

    Science.gov (United States)

    Stefansic, James D; Bass, W Andrew; Hartmann, Steven L; Beasley, Ryan A; Sinha, Tuhin K; Cash, David M; Herline, Alan J; Galloway, Robert L

    2002-11-01

    In interactive, image-guided surgery, current physical space position in the operating room is displayed on various sets of medical images used for surgical navigation. We have developed a PC-based surgical guidance system (ORION) which synchronously displays surgical position on up to four image sets and updates them in real time. There are three essential components which must be developed for this system: (1) accurately tracked instruments; (2) accurate registration techniques to map physical space to image space; and (3) methods to display and update the image sets on a computer monitor. For each of these components, we have developed a set of dynamic link libraries in MS Visual C++ 6.0 supporting various hardware tools and software techniques. Surgical instruments are tracked in physical space using an active optical tracking system. Several of the different registration algorithms were developed with a library of robust math kernel functions, and the accuracy of all registration techniques was thoroughly investigated. Our display was developed using the Win32 API for windows management and tomographic visualization, a frame grabber for live video capture, and OpenGL for visualization of surface renderings. We have begun to use this current implementation of our system for several surgical procedures, including open and minimally invasive liver surgery.

  11. A cable-driven soft robot surgical system for cardiothoracic endoscopic surgery: preclinical tests in animals.

    Science.gov (United States)

    Wang, Hesheng; Zhang, Runxi; Chen, Weidong; Wang, Xiaozhou; Pfeifer, Rolf

    2017-08-01

    Minimally invasive surgery attracts more and more attention because of the advantages of minimal trauma, less bleeding and pain and low complication rate. However, minimally invasive surgery for beating hearts is still a challenge. Our goal is to develop a soft robot surgical system for single-port minimally invasive surgery on a beating heart. The soft robot described in this paper is inspired by the octopus arm. Although the octopus arm is soft and has more degrees of freedom (DOFs), it can be controlled flexibly. The soft robot is driven by cables that are embedded into the soft robot manipulator and can control the direction of the end and middle of the soft robot manipulator. The forward, backward and rotation movement of the soft robot is driven by a propulsion plant. The soft robot can move freely by properly controlling the cables and the propulsion plant. The soft surgical robot system can perform different thoracic operations by changing surgical instruments. To evaluate the flexibility, controllability and reachability of the designed soft robot surgical system, some testing experiments have been conducted in vivo on a swine. Through the subxiphoid, the soft robot manipulator could enter into the thoracic cavity and pericardial cavity smoothly and perform some operations such as biopsy, ligation and ablation. The operations were performed successfully and did not cause any damage to the surrounding soft tissues. From the experiments, the flexibility, controllability and reachability of the soft robot surgical system have been verified. Also, it has been shown that this system can be used in the thoracic and pericardial cavity for different operations. Compared with other endoscopy robots, the soft robot surgical system is safer, has more DOFs and is more flexible for control. When performing operations in a beating heart, this system maybe more suitable than traditional endoscopy robots.

  12. Contributory factors in surgical incidents as delineated by a confidential reporting system.

    Science.gov (United States)

    Mushtaq, F; O'Driscoll, C; Smith, Fct; Wilkins, D; Kapur, N; Lawton, R

    2018-05-01

    Background Confidential reporting systems play a key role in capturing information about adverse surgical events. However, the value of these systems is limited if the reports that are generated are not subjected to systematic analysis. The aim of this study was to provide the first systematic analysis of data from a novel surgical confidential reporting system to delineate contributory factors in surgical incidents and document lessons that can be learned. Methods One-hundred and forty-five patient safety incidents submitted to the UK Confidential Reporting System for Surgery over a 10-year period were analysed using an adapted version of the empirically-grounded Yorkshire Contributory Factors Framework. Results The most common factors identified as contributing to reported surgical incidents were cognitive limitations (30.09%), communication failures (16.11%) and a lack of adherence to established policies and procedures (8.81%). The analysis also revealed that adverse events were only rarely related to an isolated, single factor (20.71%) - with the majority of cases involving multiple contributory factors (79.29% of all cases had more than one contributory factor). Examination of active failures - those closest in time and space to the adverse event - pointed to frequent coupling with latent, systems-related contributory factors. Conclusions Specific patterns of errors often underlie surgical adverse events and may therefore be amenable to targeted intervention, including particular forms of training. The findings in this paper confirm the view that surgical errors tend to be multi-factorial in nature, which also necessitates a multi-disciplinary and system-wide approach to bringing about improvements.

  13. Opportunities for system level improvement in antibiotic use across the surgical pathway

    Directory of Open Access Journals (Sweden)

    E. Charani

    2017-07-01

    Full Text Available Optimizing antibiotic prescribing across the surgical pathway (before, during, and after surgery is a key aspect of tackling important drivers of antimicrobial resistance and simultaneously decreasing the burden of infection at the global level. In the UK alone, 10 million patients undergo surgery every year, which is equivalent to 60% of the annual hospital admissions having a surgical intervention. The overwhelming majority of surgical procedures require effectively limited delivery of antibiotic prophylaxis to prevent infections. Evidence from around the world indicates that antibiotics for surgical prophylaxis are administered ineffectively, or are extended for an inappropriate duration of time postoperatively. Ineffective antibiotic prophylaxis can contribute to the development of surgical site infections (SSIs, which represent a significant global burden of disease. The World Health Organization estimates SSI rates of up to 50% in postoperative surgical patients (depending on the type of surgery, with a particular problem in low- and middle-income countries, where SSIs are the most frequently reported healthcare-associated infections. Across European hospitals, SSIs alone comprise 19.6% of all healthcare-acquired infections. Much of the scientific research in infection management in surgery is related to infection prevention and control in the operating room, surgical prophylaxis, and the management of SSIs, with many studies focusing on infection within the 30-day postoperative period. However it is important to note that SSIs represent only one of the many types of infection that can occur postoperatively. This article provides an overview of the surgical pathway and considers infection management and antibiotic prescribing at each step of the pathway. The aim was to identify the implications for research and opportunities for system improvement.

  14. Opportunities for system level improvement in antibiotic use across the surgical pathway.

    Science.gov (United States)

    Charani, E; Ahmad, R; Tarrant, C; Birgand, G; Leather, A; Mendelson, M; Moonesinghe, S R; Sevdalis, N; Singh, S; Holmes, A

    2017-07-01

    Optimizing antibiotic prescribing across the surgical pathway (before, during, and after surgery) is a key aspect of tackling important drivers of antimicrobial resistance and simultaneously decreasing the burden of infection at the global level. In the UK alone, 10 million patients undergo surgery every year, which is equivalent to 60% of the annual hospital admissions having a surgical intervention. The overwhelming majority of surgical procedures require effectively limited delivery of antibiotic prophylaxis to prevent infections. Evidence from around the world indicates that antibiotics for surgical prophylaxis are administered ineffectively, or are extended for an inappropriate duration of time postoperatively. Ineffective antibiotic prophylaxis can contribute to the development of surgical site infections (SSIs), which represent a significant global burden of disease. The World Health Organization estimates SSI rates of up to 50% in postoperative surgical patients (depending on the type of surgery), with a particular problem in low- and middle-income countries, where SSIs are the most frequently reported healthcare-associated infections. Across European hospitals, SSIs alone comprise 19.6% of all healthcare-acquired infections. Much of the scientific research in infection management in surgery is related to infection prevention and control in the operating room, surgical prophylaxis, and the management of SSIs, with many studies focusing on infection within the 30-day postoperative period. However it is important to note that SSIs represent only one of the many types of infection that can occur postoperatively. This article provides an overview of the surgical pathway and considers infection management and antibiotic prescribing at each step of the pathway. The aim was to identify the implications for research and opportunities for system improvement. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  15. The use of vertical constructed wetland and ultrasound in aquaponic systems.

    Science.gov (United States)

    Krivograd Klemenčič, A; Griessler Bulc, T

    2015-01-01

    Treatment performance, fish production, crop plant biomass production, water consumption, and water use efficiency of a pilot aquaponic system for small-scale land-based cyprinid fish farms were evaluated. The system consisted of a 36 m(3) Pond A with an initial carp load of 0.6 kg/m(3); of a treatment chain with a lamellar settler, a roughing filter, a vertical constructed wetland filled with expanded clay and planted with tomatoes; and of a low power ultrasound unit installed in the corner of the pond. The average circulation of the water in the system was 1.2 times per day. Pond A was compared with Pond B of the same dimensions and fish load but with no treatment chain or ultrasound. The treatment chain was efficient in mass removal of total suspended solids , biochemical oxygen demand, chemical oxygen demand, NH4-N, total nitrogen, and total phosphorous (57, 49, 35, 42, 31, and 25 %, respectively). Negative removal of NO3-N, NO2-N, and PO4-P indicated the need for the introduction of additional hydroponic beds in the system. Pond A had markedly lower nutrient concentrations compared with Pond B. Fish body weight increase and specific growth rate in Pond A were higher than in Pond B (102.6 %, 72.1 %; 0.19 %/day, 0.14 %/day, respectively) indicating better rearing conditions in Pond A. Tomato biomass production was high. Water use efficiency was higher in Pond A compared with Pond B (0.31 kg of produced fish/m(3) inflow water and 0.22 kg of produced fish/m(3) inflow water, respectively). The presented aquaponic system could be useful for semi-natural fish farming with fish loads up to 2 kg/m(3).

  16. Novel Use of Ultrasound to Teach Reproductive System Physical Examination Skills and Pelvic Anatomy.

    Science.gov (United States)

    Parikh, Tejal; Czuzak, Maria; Bui, Naomi; Wildner, Corinna; Koch, Bryna; Leko, Elizabeth; Rappaport, William; Adhikari, Srikar; Gordon, Paul; Gura, Mike; Ellis, Susan

    2018-03-01

    To determine whether integration of ultrasound (US) into a reproductive system examination clinical skills lab can increase confidence in palpating key reproductive structures during testicular and bimanual pelvic examinations, reduce anxiety about conducting testicular and bimanual pelvic examinations, and improve performance on multiple-choice questions based on structure identification using US images. Second-year medical students enrolled in the Life Cycle preclinical course participated in this cross-sectional study. A single learning activity was developed to pair the teaching of the reproductive system physical examination with the use of US in the clinical skills lab. The evaluation of the teaching session consisted of a pre-post analysis of student self-reported knowledge, confidence, and anxiety. The response rate for the pre survey was 82% (n = 96), and the rate for the post survey was 79% (n = 93). Students' confidence in their ability to identify reproductive system structures on US images increased from pre to post survey. Their confidence in their ability to palpate the epididymis, uterus, and ovary during a physical examination improved, and their anxiety about conducting testicular and bimanual pelvic examinations decreased. Student satisfaction with the session was high. Students' performance on multiple-choice questions based on structure identification using US images was at 96% or higher. Our study findings support the integration of US into a reproductive system examination clinical skills lab. Medical students acquire competency and confidence in reproductive system physical examination skills with US integration. © 2017 by the American Institute of Ultrasound in Medicine.

  17. Experience with a small animal hyperthermia ultrasound system (SAHUS): report on 83 tumours

    International Nuclear Information System (INIS)

    Novak, P; Moros, E G; Parry, J J; Rogers, B E; Myerson, R J; Zeug, A; Locke, J E; Rossin, R; Straube, W L; Singh, A K

    2005-01-01

    An external local ultrasound (US) system was developed to induce controlled hyperthermia of subcutaneously implanted tumours in small animals (e.g., mice and rats). It was designed to be compatible with a small animal positron emission tomography scanner (microPET) to facilitate studies of hyperthermia-induced tumour re-oxygenation using a PET radiopharmaceutical, but it is applicable for any small animal study requiring controlled heating. The system consists of an acrylic applicator bed with up to four independent 5 MHz planar disc US transducers of 1 cm in diameter, a four-channel radiofrequency (RF) generator, a multiple thermocouple thermometry unit, and a personal computer with custom monitoring and controlling software. Although the system presented here was developed to target tumours of up to 1 cm in diameter, the applicator design allows for different piezoelectric transducers to be exchanged and operated within the 3.5-6.5 MHz band to target different tumour sizes. Temperature feedback control software was developed on the basis of a proportional-integral-derivative (PID) approach when the measured temperatures were within a selectable temperature band about the target temperature. Outside this band, an on/off control action was applied. Perfused tissue-mimicking phantom experiments were performed to determine optimum controller gain constants, which were later employed successfully in animal experiments. The performance of the SAHUS (small animal hyperthermia ultrasound system) was tested using several tumour types grown in thighs of female nude (nu/nu) mice. To date, the system has successfully treated 83 tumours to target temperatures in the range of 41-43 deg. C for periods of 65 min on average

  18. Ultrasound Findings on Hands and Wrists of Patients with Systemic Lupus Erythematosus: Relationship with Physical Examination.

    Science.gov (United States)

    Lins, Carolina Freitas; Lima de Sá Ribeiro, Daniel; Dourado Santos, Willer Gonçalves; Rosa, Genevievi; Machicado, Viviane; Pedreira, Ana Luisa; Pimenta da Fonseca, Emanuela; Mota Duque Sousa, Anna Paula; Rodrigues Silva, Carla Baleeiro; Matos, Marcos Antonio Almeida; Santiago, Mittermayer Barreto

    2017-09-01

    Diagnosis of synovitis/tenosynovitis by physical examination can be difficult. Ultrasound (US) can be an effective tool for the evaluation of joint involvement in systemic lupus erythematosus (SLE). This study will describe musculoskeletal findings by US in SLE patients and the evaluation of their correlation with physical examination. SLE patients underwent clinical/sonographic evaluation of hand/wrists. In total, 896 joints were evaluated: at least 1 change on physical examination was found in 136 joints and at least 1 US abnormality was found in 65 of 896 joints. Out of the 65 joints with US changes, only 13 had findings on physical examination. Conversely, 111 joints had tenderness on physical examination with no sonographic abnormalities. Tenosynovitis was statistically significant more frequently with joint edema (41%) (p = 0.0003). US can detect musculoskeletal changes in only a minority of symptomatic SLE patients. Clinical findings may be related to some reasons that cannot be explained using US. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  19. Development of an integrated automated retinal surgical laser system.

    Science.gov (United States)

    Barrett, S F; Wright, C H; Oberg, E D; Rockwell, B A; Cain, C; Rylander, H G; Welch, A J

    1996-01-01

    Researchers at the University of Texas and the USAF Academy have worked toward the development of a retinal robotic laser system. The overall goal of this ongoing project is to precisely place and control the depth of laser lesions for the treatment of various retinal diseases such as diabetic retinopathy and retinal tears. Separate low speed prototype subsystems have been developed to control lesion depth using lesion reflectance feedback parameters and lesion placement using retinal vessels as tracking landmarks. Both subsystems have been successfully demonstrated in vivo on pigmented rabbits using an argon continuous wave laser. Preliminary testing on rhesus primate subjects have been accomplished with the CW argon laser and also the ultrashort pulse laser. Recent efforts have concentrated on combining the two subsystems into a single prototype capable of simultaneously controlling both lesion depth and placement. We have designated this combined system CALOSOS for Computer Aided Laser Optics System for Ophthalmic Surgery. Several interesting areas of study have developed in integrating the two subsystems: 1) "doughnut" shaped lesions that occur under certain combinations of laser power, spot size, and irradiation time complicating measurements of central lesion reflectance, 2) the optimal retinal field of view (FOV) to achieve both tracking and lesion parameter control, and 3) development of a hybrid analog/digital tracker using confocal reflectometry to achieve retinal tracking speeds of up to 100 dgs. This presentation will discuss these design issues of this clinically significant prototype system. Details of the hybrid prototype system are provided in "Hybrid Eye Tracking for Computer-Aided Retinal Surgery" at this conference. The paper will close with remaining technical hurdles to clear prior to testing the full-up clinical prototype system.

  20. Modelling and Experiment Based on a Navigation System for a Cranio-Maxillofacial Surgical Robot

    Science.gov (United States)

    Duan, Xingguang; Gao, Liang; Li, Jianxi; Li, Haoyuan; Guo, Yanjun

    2018-01-01

    In view of the characteristics of high risk and high accuracy in cranio-maxillofacial surgery, we present a novel surgical robot system that can be used in a variety of surgeries. The surgical robot system can assist surgeons in completing biopsy of skull base lesions, radiofrequency thermocoagulation of the trigeminal ganglion, and radioactive particle implantation of skull base malignant tumors. This paper focuses on modelling and experimental analyses of the robot system based on navigation technology. Firstly, the transformation relationship between the subsystems is realized based on the quaternion and the iterative closest point registration algorithm. The hand-eye coordination model based on optical navigation is established to control the end effector of the robot moving to the target position along the planning path. The closed-loop control method, “kinematics + optics” hybrid motion control method, is presented to improve the positioning accuracy of the system. Secondly, the accuracy of the system model was tested by model experiments. And the feasibility of the closed-loop control method was verified by comparing the positioning accuracy before and after the application of the method. Finally, the skull model experiments were performed to evaluate the function of the surgical robot system. The results validate its feasibility and are consistent with the preoperative surgical planning. PMID:29599948

  1. Modelling and Experiment Based on a Navigation System for a Cranio-Maxillofacial Surgical Robot

    Directory of Open Access Journals (Sweden)

    Xingguang Duan

    2018-01-01

    Full Text Available In view of the characteristics of high risk and high accuracy in cranio-maxillofacial surgery, we present a novel surgical robot system that can be used in a variety of surgeries. The surgical robot system can assist surgeons in completing biopsy of skull base lesions, radiofrequency thermocoagulation of the trigeminal ganglion, and radioactive particle implantation of skull base malignant tumors. This paper focuses on modelling and experimental analyses of the robot system based on navigation technology. Firstly, the transformation relationship between the subsystems is realized based on the quaternion and the iterative closest point registration algorithm. The hand-eye coordination model based on optical navigation is established to control the end effector of the robot moving to the target position along the planning path. The closed-loop control method, “kinematics + optics” hybrid motion control method, is presented to improve the positioning accuracy of the system. Secondly, the accuracy of the system model was tested by model experiments. And the feasibility of the closed-loop control method was verified by comparing the positioning accuracy before and after the application of the method. Finally, the skull model experiments were performed to evaluate the function of the surgical robot system. The results validate its feasibility and are consistent with the preoperative surgical planning.

  2. Robot-Assisted Fracture Surgery: Surgical Requirements and System Design.

    Science.gov (United States)

    Georgilas, Ioannis; Dagnino, Giulio; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2018-03-09

    The design of medical devices is a complex and crucial process to ensure patient safety. It has been shown that improperly designed devices lead to errors and associated accidents and costs. A key element for a successful design is incorporating the views of the primary and secondary stakeholders early in the development process. They provide insights into current practice and point out specific issues with the current processes and equipment in use. This work presents how information from a user-study conducted in the early stages of the RAFS (Robot Assisted Fracture Surgery) project informed the subsequent development and testing of the system. The user needs were captured using qualitative methods and converted to operational, functional, and non-functional requirements based on the methods derived from product design and development. This work presents how the requirements inform a new workflow for intra-articular joint fracture reduction using a robotic system. It is also shown how the various elements of the system are developed to explicitly address one or more of the requirements identified, and how intermediate verification tests are conducted to ensure conformity. Finally, a validation test in the form of a cadaveric trial confirms the ability of the designed system to satisfy the aims set by the original research question and the needs of the users.

  3. A Fully Sensorized Cooperative Robotic System for Surgical Interventions

    Science.gov (United States)

    Tovar-Arriaga, Saúl; Vargas, José Emilio; Ramos, Juan M.; Aceves, Marco A.; Gorrostieta, Efren; Kalender, Willi A.

    2012-01-01

    In this research a fully sensorized cooperative robot system for manipulation of needles is presented. The setup consists of a DLR/KUKA Light Weight Robot III especially designed for safe human/robot interaction, a FD-CT robot-driven angiographic C-arm system, and a navigation camera. Also, new control strategies for robot manipulation in the clinical environment are introduced. A method for fast calibration of the involved components and the preliminary accuracy tests of the whole possible errors chain are presented. Calibration of the robot with the navigation system has a residual error of 0.81 mm (rms) with a standard deviation of ±0.41 mm. The accuracy of the robotic system while targeting fixed points at different positions within the workspace is of 1.2 mm (rms) with a standard deviation of ±0.4 mm. After calibration, and due to close loop control, the absolute positioning accuracy was reduced to the navigation camera accuracy which is of 0.35 mm (rms). The implemented control allows the robot to compensate for small patient movements. PMID:23012551

  4. Quality Assurance of Ultrasound Imaging Systems for Target Localization and Online Setup Corrections

    International Nuclear Information System (INIS)

    Tome, Wolfgang A.; Orton, Nigel P.

    2008-01-01

    We describe quality assurance paradigms for ultrasound imaging systems for target localization (UISTL). To determine the absolute localization accuracy of a UISTL, an absolute coordinate system can be established in the treatment room and spherical targets at various depths can be localized. To test the ability of such a system to determine the magnitude of internal organ motion, a phantom that mimics the human male pelvic anatomy can be used to simulate different organ motion ranges. To assess the interuser variability of ultrasound (US) guidance, different experienced users can independently determine the daily organ shifts for the same patients for a number of consecutive fractions. The average accuracy for a UISTL for the localization of spherical targets at various depths has been found to be 0.57 ± 0.47 mm in each spatial dimension for various focal depths. For the phantom organ motion test it was found that the true organ motion could be determined to within 1.0 mm along each axis. The variability between different experienced users who localized the same 5 patients for five consecutive fractions was small in comparison to the indicated shifts. In addition to the quality assurance tests that address the ability of a UISTL to accurately localize a target, a thorough quality assurance program should also incorporate the following two aspects to ensure consistent and accurate localization in daily clinical use: (1) adequate training and performance monitoring of users of the US target localization system, and (2) prescreening of patients who may not be good candidates for US localization

  5. Ultrasound guided implantation of chest port systems via the lateral subclavian vein

    International Nuclear Information System (INIS)

    Zaehringer, M.; Hilgers, J.; Krueger, K.; Strohe, D.; Bangard, C.; Neumann, L.; Lackner, K.; Warm, M.; Reiser, M.; Toex, U.

    2006-01-01

    Purpose: Retrospective analysis of the success and complication rates of chest port implantation via the lateral subclavian vein. Materials and methods: Between January 2003 and June 2004, the lateral subclavian vein in 271 patients (186 women, 85 men, mean age 53.2 years) was punctured guided by ultrasound. This access was used to insert a port system, and the catheter tip was placed at the cavoatrial junction. The port reservoir was implanted in a subcutaneous infraclavicular pocket and fixed to the fascia of the pectoralis muscle. Indications for port implantation were chemotherapy (n=239), total parenteral nutrition (n=2) and intravenous medication (n=30). The patient follow-up was mainly performed either by the oncology division of the department of gynecology or by the department of internal medicine. Results: A chest port catheter system was successfully implanted in all patients. The catheter remained in place for a mean duration of 269.4 days (SD 192.3 days). No complications occurred during implantation. In the post-interventional period, 6 catheter dysfunctions were found (thrombotic 0.09 per 1000 catheter days; mechanic 0.05 per 1000 catheter days). While one local infection occurred in the early post-interventional period, 3 local and 15 systemic infections were independent of the port catheter placement (0.39 per 1000 catheter days). The rate of port catheter explantations due to dysfunction or infection was 0.07 per 1000 catheter days. Conclusion: Ultrasound-guided puncture of the lateral subclavian vein is a safe procedure for the insertion of central venous port catheter systems and had a very low complication rate in our study. For further evaluation of our port placement technique, prospective studies compared to placement through the internal jugular vein are necessary. (orig.)

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page This page was reviewed on ... Abdomen Children's (Pediatric) Ultrasound - Abdomen Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding ... Images related to Ultrasound - Pelvis Sponsored by Please ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding Ovarian Cancer Images related to Ultrasound - Pelvis Sponsored ...

  8. Development of surgical CW Nd:YAG laser with optical fiber delivery system

    International Nuclear Information System (INIS)

    Kim, Cheol Jung; Kim, Jeong Mook; Jung, Chin Mann; Kim, Kwang Suk; Kim, Min Suk; Cho, Jae Wan; Kim, Duk Hyun

    1992-06-01

    We developed a surgical CW Nd:YAG laser with optical fiber delivery system. Several commercial models have been investigated in design and performance. We improved its quality to the level of commercial Nd:YAG laser by an endurance test for each parts of laser system. The maximum power of our surgical laser was 150 W and the laser pulse width could be controlled to 99 sec continuously by 0.1 sec. Many optical parts were localized and lowered much in cost. Only few parts were imported and almost 90% in cost were localized. Also, to find out the maintenance problem of this surgical laser, it was applicated to the production line of our joint company. (Author)

  9. Evaluation of an automated breast 3D-ultrasound system by comparing it with hand-held ultrasound (HHUS) and mammography.

    Science.gov (United States)

    Golatta, Michael; Baggs, Christina; Schweitzer-Martin, Mirjam; Domschke, Christoph; Schott, Sarah; Harcos, Aba; Scharf, Alexander; Junkermann, Hans; Rauch, Geraldine; Rom, Joachim; Sohn, Christof; Heil, Joerg

    2015-04-01

    Automated three-dimensional (3D) breast ultrasound (US) systems are meant to overcome the shortcomings of hand-held ultrasound (HHUS). The aim of this study is to analyze and compare clinical performance of an automated 3D-US system by comparing it with HHUS, mammography and the clinical gold standard (defined as the combination of HHUS, mammography and-if indicated-histology). Nine hundred and eighty three patients (=1,966 breasts) were enrolled in this monocentric, explorative and prospective cohort study. All examinations were analyzed blinded to the patients´ history and to the results of the routine imaging. The agreement of automated 3D-US with HHUS, mammography and the gold standard was assessed with kappa statistics. Sensitivity, specificity and positive and negative predictive value were calculated to assess the test performance. Blinded to the results of the gold standard the agreement between automated 3D-US and HHUS or mammography was fair, given by a Kappa coefficient of 0.31 (95% CI [0.26;0.36], p automated 3D-US the sensitivity improved to 84% (NPV = 99%, specificity = 85%). The results of this study let us suggest, that automated 3D-US might be a helpful new tool in breast imaging, especially in screening.

  10. Making Safe Surgery Affordable: Design of a Surgical Drill Cover System for Scale.

    Science.gov (United States)

    Buchan, Lawrence L; Black, Marianne S; Cancilla, Michael A; Huisman, Elise S; Kooyman, Jeremy J R; Nelson, Scott C; OʼHara, Nathan N; OʼBrien, Peter J; Blachut, Piotr A

    2015-10-01

    Many surgeons in low-resource settings do not have access to safe, affordable, or reliable surgical drilling tools. Surgeons often resort to nonsterile hardware drills because they are affordable, robust, and efficient, but they are impossible to sterilize using steam. A promising alternative is to use a Drill Cover system (a sterilizable fabric bag plus surgical chuck adapter) so that a nonsterile hardware drill can be used safely for surgical bone drilling. Our objective was to design a safe, effective, affordable Drill Cover system for scale in low-resource settings. We designed our device based on feedback from users at Mulago Hospital (Kampala, Uganda) and focused on 3 main aspects. First, the design included a sealed barrier between the surgical field and hardware drill that withstands pressurized fluid. Second, the selected hardware drill had a maximum speed of 1050 rpm to match common surgical drills and reduce risk of necrosis. Third, the fabric cover was optimized for ease of assembly while maintaining a sterile technique. Furthermore, with the Drill Cover approach, multiple Drill Covers can be provided with a single battery-powered drill in a "kit," so that the drill can be used in back-to-back surgeries without requiring immediate sterilization. The Drill Cover design presented here provides a proof-of-concept for a product that can be commercialized, produced at scale, and used in low-resource settings globally to improve access to safe surgery.

  11. SURGNET: An Integrated Surgical Data Transmission System for Telesurgery.

    Science.gov (United States)

    Natarajan, Sriram; Ganz, Aura

    2009-01-01

    Remote surgery information requires quick and reliable transmission between the surgeon and the patient site. However, the networks that interconnect the surgeon and patient sites are usually time varying and lossy which can cause packet loss and delay jitter. In this paper we propose SURGNET, a telesurgery system for which we developed the architecture, algorithms and implemented it on a testbed. The algorithms include adaptive packet prediction and buffer time adjustment techniques which reduce the negative effects caused by the lossy and time varying networks. To evaluate the proposed SURGNET system, at the therapist site, we implemented a therapist panel which controls the force feedback device movements and provides image analysis functionality. At the patient site we controlled a virtual reality applet built in Matlab. The varying network conditions were emulated using NISTNet emulator. Our results show that even for severe packet loss and variable delay jitter, the proposed integrated synchronization techniques significantly improve SURGNET performance.

  12. Thorascopic resection of an apical paraspinal schwannoma using the da Vinci surgical system.

    Science.gov (United States)

    Finley, David; Sherman, Jonathan H; Avila, Edward; Bilsky, Mark

    2014-01-01

    Posterior mediastinal neurogenic tumors have traditionally been resected via an open posterolateral thoracotomy. Video-assisted thorascopic surgery has emerged as an alternative technique allowing for improved morbidity with decreased blood loss, less postoperative pain, and a shorter recovery period, among others. The da Vinci surgical system, as first described for urologic procedures, has recently been reported for lung lobectomy. This technique provides the advantages of instrumentation with 6 degrees of freedom, stable operating arms, and improved visualization with the three-dimensional high-definition camera. We describe the technique for thorascopic resection of an apical paraspinal schwannoma of the T1 nerve root with the da Vinci surgical system. This technique used a specialized intraoperative neuromonitoring probe for free-running electromyography (EMG) and triggered EMG. We demonstrate successful resection of a posterior paraspinal schwannoma with the da Vinci surgical system while preserving neurologic function. The patient displayed stable intraoperative monitoring of the T1 nerve root and full intrinsic hand strength postoperatively. The technique described in this article introduces robotic system accuracy and precludes the need for an open thoracotomy. In addition, this approach demonstrates the ability of the da Vinci surgical system to safely dissect tumors from their neural attachments and is applicable to other such lesions of similar size and location. Georg Thieme Verlag KG Stuttgart · New York.

  13. Compact teleoperated laparoendoscopic single-site robotic surgical system: Kinematics, control, and operation.

    Science.gov (United States)

    Isaac-Lowry, Oran Jacob; Okamoto, Steele; Pedram, Sahba Aghajani; Woo, Russell; Berkelman, Peter

    2017-12-01

    To date a variety of teleoperated surgical robotic systems have been developed to improve a surgeon's ability to perform demanding single-port procedures. However typical large systems are bulky, expensive, and afford limited angular motion, while smaller designs suffer complications arising from limited motion range, speed, and force generation. This work was to develop and validate a simple, compact, low cost single site teleoperated laparoendoscopic surgical robotic system, with demonstrated capability to carry out basic surgical procedures. This system builds upon previous work done at the University of Hawaii at Manoa and includes instrument and endoscope manipulators as well as compact articulated instruments designed to overcome single incision geometry complications. A robotic endoscope holder was used for the base, with an added support frame for teleoperated manipulators and instruments fabricated mostly from 3D printed parts. Kinematics and control methods were formulated for the novel manipulator configuration. Trajectory following results from an optical motion tracker and sample task performance results are presented. Results indicate that the system has successfully met the goal of basic surgical functionality while minimizing physical size, complexity, and cost. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Development of stereo endoscope system with its innovative master interface for continuous surgical operation.

    Science.gov (United States)

    Kim, Myungjoon; Lee, Chiwon; Hong, Nhayoung; Kim, Yoon Jae; Kim, Sungwan

    2017-06-24

    Although robotic laparoscopic surgery has various benefits when compared with conventional open surgery and minimally invasive surgery, it also has issues to overcome and one of the issues is the discontinuous surgical flow that occurs whenever control is swapped between the endoscope system and the operating robot arm system. This can lead to problems such as collision between surgical instruments, injury to patients, and increased operation time. To achieve continuous surgical operation, a wireless controllable stereo endoscope system is proposed which enables the simultaneous control of the operating robot arm system and the endoscope system. The proposed system consists of two improved novel master interfaces (iNMIs), a four-degrees of freedom (4-DOFs) endoscope control system (ECS), and a simple three-dimensional (3D) endoscope. In order to simultaneously control the proposed system and patient side manipulators of da Vinci research kit (dVRK), the iNMIs are installed to the master tool manipulators of dVRK system. The 4-DOFs ECS consists of four servo motors and employs a two-parallel link structure to provide translational and fulcrum point motion to the simple 3D endoscope. The images acquired by the endoscope undergo stereo calibration and rectification to provide a clear 3D vision to the surgeon as available in clinically used da Vinci surgical robot systems. Tests designed to verify the accuracy, data transfer time, and power consumption of the iNMIs were performed. The workspace was calculated to estimate clinical applicability and a modified peg transfer task was conducted with three novice volunteers. The iNMIs operated for 317 min and moved in accordance with the surgeon's desire with a mean latency of 5 ms. The workspace was calculated to be 20378.3 cm 3 , which exceeds the reference workspace of 549.5 cm 3 . The novice volunteers were able to successfully execute the modified peg transfer task designed to evaluate the proposed system's overall

  15. Person or system - What leads to surgical advances?

    Science.gov (United States)

    Hughes, Sean Pf

    2017-01-01

    To understand the relationship between standardisation and originality in surgery, the contributions of three surgeons in the 20th century are analysed. The individual Arbuthnot Lane, the collectivist Robert Jones and the scientist Alexis Carrel changed the practice of orthopaedic surgery. It is argued that the factors influencing innovation are not binary but multifactorial and that advances in surgery occur when individual freedom is permitted within a system. It is concluded that innovation and standardisation in orthopaedic surgery need not conflict with each other.

  16. Ultrasound skin tightening.

    Science.gov (United States)

    Minkis, Kira; Alam, Murad

    2014-01-01

    Ultrasound skin tightening is a noninvasive, nonablative method that allows for energy deposition into the deep dermal and subcutaneous tissue while avoiding epidermal heating. Ultrasound coagulation is confined to arrays of 1-mm(3) zones that include the superficial musculoaponeurotic system and connective tissue. This technology gained approval from the Food and Drug Administration as the first energy-based skin "lifting" device, specifically for lifting lax tissue on the neck, submentum, and eyebrows. Ultrasound has the unique advantage of direct visualization of treated structures during treatment. Ultrasound is a safe and efficacious treatment for mild skin tightening and lifting. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Novel power MOSFET-based expander for high frequency ultrasound systems.

    Science.gov (United States)

    Choi, Hojong; Shung, K Kirk

    2014-01-01

    The function of an expander is to obstruct the noise signal transmitted by the pulser so that it does not pass into the transducer or receive electronics, where it can produce undesirable ring-down in an ultrasound imaging application. The most common type is a diode-based expander, which is essentially a simple diode-pair, is widely used in pulse-echo measurements and imaging applications because of its simple architecture. However, diode-based expanders may degrade the performance of ultrasonic transducers and electronic components on the receiving and transmitting sides of the ultrasound systems, respectively. Since they are non-linear devices, they cause excessive signal attenuation and noise at higher frequencies and voltages. In this paper, a new type of expander that utilizes power MOSFET components, which we call a power MOSFET-based expander, is introduced and evaluated for use in high frequency ultrasound imaging systems. The performance of a power MOSFET-based expander was evaluated relative to a diode-based expander by comparing the noise figure (NF), insertion loss (IL), total harmonic distortion (THD), response time (RT), electrical impedance (EI) and dynamic power consumption (DPC). The results showed that the power MOSFET-based expander provided better NF (0.76 dB), IL (-0.3 dB) and THD (-62.9 dB), and faster RT (82 ns) than did the diode-based expander (NF (2.6 dB), IL (-1.4 dB), THD (-56.0 dB) and RT (119 ns)) at 70 MHz. The -6 dB bandwidth and the peak-to-peak voltage of the echo signal received by the transducer using the power MOSFET-based expander improved by 17.4% and 240% compared to the diode-based expander, respectively. The new power MOSFET-based expander was shown to yield lower NF, IL and THD, faster RT and lower ring down than the diode-based expander at the expense of higher dynamic power consumption. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. LED surgical lighting system with multiple free-form surfaces for highly sterile operating theater application.

    Science.gov (United States)

    Liu, Peng; Zhang, Yaqin; Zheng, Zhenrong; Li, Haifeng; Liu, Xu

    2014-06-01

    Although the ventilation system is widely employed in the operating theater, a strictly sterile surgical environment still cannot be ensured because of laminar disturbance, which is mainly caused by the surgical lighting system. Abandoning traditional products, we propose an LED surgical lighting system, which can alleviate the laminar disturbance and provide an appropriate lighting condition for surgery. It contains a certain amount of LED lens units, which are embedded in the ceiling and arranged around the air supply smallpox. The LED lens unit integrated with an LED light source and a free-form lens is required to produce a uniform circular illumination with a large tolerance to the change of lighting distance. To achieve such a dedicated lens, two free-form refractive surfaces, which are converted into two ordinary differential equations by the design method presented in this paper, are used to deflect the rays. The results show that the LED surgical lighting system can provide an excellent illumination environment for surgery, and, apparently, the laminar disturbance also can be relieved.

  19. The surgical algorithm for the AOSpine thoracolumbar spine injury classification system

    NARCIS (Netherlands)

    Vaccaro, Alexander R.; Schroeder, Gregory D.; Kepler, Christopher K.; Cumhur Oner, F.; Vialle, Luiz R.; Kandziora, Frank; Koerner, John D.; Kurd, Mark F.; Reinhold, Max; Schnake, Klaus J.; Chapman, Jens; Aarabi, Bizhan; Fehlings, Michael G.; Dvorak, Marcel F.

    2016-01-01

    Purpose: The goal of the current study is to establish a surgical algorithm to accompany the AOSpine thoracolumbar spine injury classification system. Methods: A survey was sent to AOSpine members from the six AO regions of the world, and surgeons were asked if a patient should undergo an initial

  20. [Short-term efficacy of da Vinci robotic surgical system on rectal cancer in 101 patients].

    Science.gov (United States)

    Zeng, Dong-Zhu; Shi, Yan; Lei, Xiao; Tang, Bo; Hao, Ying-Xue; Luo, Hua-Xing; Lan, Yuan-Zhi; Yu, Pei-Wu

    2013-05-01

    To investigate the feasibility and safety of da Vinci robotic surgical system in rectal cancer radical operation, and to summarize its short-term efficacy and clinical experience. Data of 101 cases undergoing da Vinci robotic surgical system for rectal cancer radical operation from March 2010 to September 2012 were retrospectively analyzed. Evaluation was focused on operative procedure, complication, recovery and pathology. All the 101 cases underwent operation successfully and safely without conversion to open procedure. Rectal cancer radical operation with da Vinci robotic surgical system included 73 low anterior resections and 28 abdominoperineal resections. The average operative time was (210.3±47.2) min. The average blood lose was (60.5±28.7) ml without transfusion. Lymphadenectomy harvest was 17.3±5.4. Passage of first flatus was (2.7±0.7) d. Distal margin was (5.3±2.3) cm without residual cancer cells. The complication rate was 6.9%, including anastomotic leakage(n=2), perineum incision infection(n=2), pulmonary infection (n=2), urinary retention (n=1). There was no postoperative death. The mean follow-up time was(12.9±8.0) months. No local recurrence was found except 2 cases with distant metastasis. Application of da Vinci robotic surgical system in rectal cancer radical operation is safe and patients recover quickly The short-term efficacy is satisfactory.

  1. Surgical strategy for giant pituitary adenoma based on evaluation of fine feeding system and angioarchitecture

    Directory of Open Access Journals (Sweden)

    Yoshikazu Ogawa, M.D., Ph.D.

    2017-06-01

    Conclusion: Major blood supply was different from the normal supply to the anterior pituitary gland and did not necessarily correspond to tumor shape and extension. Surgical strategy should be established based on the tumor feeding systems and hemodynamics in giant pituitary adenomas.

  2. Virtual Reality Training System for Anytime/Anywhere Acquisition of Surgical Skills: A Pilot Study.

    Science.gov (United States)

    Zahiri, Mohsen; Booton, Ryan; Nelson, Carl A; Oleynikov, Dmitry; Siu, Ka-Chun

    2018-03-01

    This article presents a hardware/software simulation environment suitable for anytime/anywhere surgical skills training. It blends the advantages of physical hardware and task analogs with the flexibility of virtual environments. This is further enhanced by a web-based implementation of training feedback accessible to both trainees and trainers. Our training system provides a self-paced and interactive means to attain proficiency in basic tasks that could potentially be applied across a spectrum of trainees from first responder field medical personnel to physicians. This results in a powerful training tool for surgical skills acquisition relevant to helping injured warfighters.

  3. Power MOSFET-diode-based limiter for high-frequency ultrasound systems.

    Science.gov (United States)

    Choi, Hojong; Kim, Min Gon; Cummins, Thomas M; Hwang, Jae Youn; Shung, K Kirk

    2014-10-01

    The purpose of the limiter circuits used in the ultrasound imaging systems is to pass low-voltage echo signals generated by ultrasonic transducers while preventing high-voltage short pulses transmitted by pulsers from damaging front-end circuits. Resistor-diode-based limiters (a 50 Ω resistor with a single cross-coupled diode pair) have been widely used in pulse-echo measurement and imaging system applications due to their low cost and simple architecture. However, resistor-diode-based limiters may not be suited for high-frequency ultrasound transducer applications since they produce large signal conduction losses at higher frequencies. Therefore, we propose a new limiter architecture utilizing power MOSFETs, which we call a power MOSFET-diode-based limiter. The performance of a power MOSFET-diode-based limiter was evaluated with respect to insertion loss (IL), total harmonic distortion (THD), and response time (RT). We compared these results with those of three other conventional limiter designs and showed that the power MOSFET-diode-based limiter offers the lowest IL (-1.33 dB) and fastest RT (0.10 µs) with the lowest suppressed output voltage (3.47 Vp-p) among all the limiters at 70 MHz. A pulse-echo test was performed to determine how the new limiter affected the sensitivity and bandwidth of the transducer. We found that the sensitivity and bandwidth of the transducer were 130% and 129% greater, respectively, when combined with the new power MOSFET-diode-based limiter versus the resistor-diode-based limiter. Therefore, these results demonstrate that the power MOSFET-diode-based limiter is capable of producing lower signal attenuation than the three conventional limiter designs at higher frequency operation. © The Author(s) 2014.

  4. 3D ultrasound system to investigate intraventricular hemorrhage in preterm neonates

    Science.gov (United States)

    Kishimoto, J.; de Ribaupierre, S.; Lee, D. S. C.; Mehta, R.; St. Lawrence, K.; Fenster, A.

    2013-11-01

    Intraventricular hemorrhage (IVH) is a common disorder among preterm neonates that is routinely diagnosed and monitored by 2D cranial ultrasound (US). The cerebral ventricles of patients with IVH often have a period of ventricular dilation (ventriculomegaly). This initial increase in ventricle size can either spontaneously resolve, which often shows clinically as a period of stabilization in ventricle size and eventual decline back towards a more normal size, or progressive ventricular dilation that does not stabilize and which may require interventional therapy to reduce symptoms relating to increased intracranial pressure. To improve the characterization of ventricle dilation, we developed a 3D US imaging system that can be used with a conventional clinical US scanner to image the ventricular system of preterm neonates at risk of ventriculomegaly. A motorized transducer housing was designed specifically for hand-held use inside an incubator using a transducer commonly used for cranial 2D US scans. This system was validated using geometric phantoms, US/MRI compatible ventricle volume phantoms, and patient images to determine 3D reconstruction accuracy and inter- and intra-observer volume estimation variability. 3D US geometric reconstruction was found to be accurate with an error of 0.05) for the measured ventricle volumes between observers. This 3D US system can reliably produce 3D US images of the neonatal ventricular system. There is the potential to use this system to monitor the progression of ventriculomegaly over time in patients with IVH.

  5. Oxidative degradation of phenols in sono-Fenton-like systems upon high-frequency ultrasound irradiation

    Science.gov (United States)

    Aseev, D. G.; Sizykh, M. R.; Batoeva, A. A.

    2017-12-01

    The kinetics of oxidative degradation of phenol and chlorophenols upon acoustic cavitation in the megahertz range (1.7 MHz) is studied experimentally in model systems, and the involvement of in situ generated reactive oxygen species (ROSs) is demonstrated. The phenols subjected to high frequency ultrasound (HFUS) are ranked in terms of their rate of conversion: 2,4,6-trichlorophenol > 2,4-dichlorophenol 2-chlorophenol > 4-chlorophenol phenol. Oxidative degradation upon HFUS irradiation is most efficient at low concentrations of pollutants, due to the low steady-state concentrations of the in situ generated ROSs. A dramatic increase is observed in the efficiency of oxidation in several sonochemical oxidative systems (HFUS in combination with other chemical oxidative factors). The system with added Fe2+ (a sono-Fenton system) derives its efficiency from hydrogen peroxide generated in situ as a result of the recombination of OH radicals. The S2O8 2-/Fe2+/HFUS system has a synergetic effect on substrate oxidation that is attributed to a radical chain mechanism. In terms of the oxidation rates, degrees of conversion, and specific energy efficiencies of 4-chlorophenol oxidation based on the amount of oxidized substance per unit of expended energy the considered sonochemical oxidative systems form the series HFUS < S2O8 2-/HFUS < S2O8 2-/Fe2+/HFUS.

  6. Poster - 09: A MATLAB-based Program for Automated Quality Assurance of a Prostate Brachytherapy Ultrasound System

    Energy Technology Data Exchange (ETDEWEB)

    Poon, Justin; Sabondjian, Eric; Sankreacha, Raxa [University of British Columbia, Dept. of Physics and Astronomy, Vancouver, BC (Canada); Trillium Health Partners – Credit Valley Hospital, Peel Regional Cancer Centre, Mississauga, ON, Trillium Health Partners – Credit Valley Hospital, Peel Regional Cancer Centre, Mississauga, ON, Trillium Health Partners – Credit Valley Hospital, Peel Regional Cancer Centre, Mississauga, ON (Canada); University of Toronto, Dept. of Radiation Oncology, Toronto, ON (Canada)

    2016-08-15

    Purpose: A robust Quality Assurance (QA) program is essential for prostate brachytherapy ultrasound systems due to the importance of imaging accuracy during treatment and planning. Task Group 128 of the American Association of Physicists in Medicine has recommended a set of QA tests covering grayscale visibility, depth of penetration, axial and lateral resolution, distance measurement, area measurement, volume measurement, and template/electronic grid alignment. Making manual measurements on the ultrasound system can be slow and inaccurate, so a MATLAB program was developed for automation of the described tests. Methods: Test images were acquired using a BK Medical Flex Focus 400 ultrasound scanner and 8848 transducer with the CIRS Brachytherapy QA Phantom – Model 045A. For each test, the program automatically segments the inputted image(s), makes the appropriate measurements, and indicates if the test passed or failed. The program was tested by analyzing two sets of images, where the measurements from the first set were used as baseline values. Results: The program successfully analyzed the images for each test and determined if any action limits were exceeded. All tests passed – the measurements made by the program were consistent and met the requirements outlined by Task Group 128. Conclusions: The MATLAB program we have developed can be used for automated QA of an ultrasound system for prostate brachytherapy. The GUI provides a user-friendly way to analyze images without the need for any manual measurement, potentially removing intra- and inter-user variability for more consistent results.

  7. Poster - 09: A MATLAB-based Program for Automated Quality Assurance of a Prostate Brachytherapy Ultrasound System

    International Nuclear Information System (INIS)

    Poon, Justin; Sabondjian, Eric; Sankreacha, Raxa

    2016-01-01

    Purpose: A robust Quality Assurance (QA) program is essential for prostate brachytherapy ultrasound systems due to the importance of imaging accuracy during treatment and planning. Task Group 128 of the American Association of Physicists in Medicine has recommended a set of QA tests covering grayscale visibility, depth of penetration, axial and lateral resolution, distance measurement, area measurement, volume measurement, and template/electronic grid alignment. Making manual measurements on the ultrasound system can be slow and inaccurate, so a MATLAB program was developed for automation of the described tests. Methods: Test images were acquired using a BK Medical Flex Focus 400 ultrasound scanner and 8848 transducer with the CIRS Brachytherapy QA Phantom – Model 045A. For each test, the program automatically segments the inputted image(s), makes the appropriate measurements, and indicates if the test passed or failed. The program was tested by analyzing two sets of images, where the measurements from the first set were used as baseline values. Results: The program successfully analyzed the images for each test and determined if any action limits were exceeded. All tests passed – the measurements made by the program were consistent and met the requirements outlined by Task Group 128. Conclusions: The MATLAB program we have developed can be used for automated QA of an ultrasound system for prostate brachytherapy. The GUI provides a user-friendly way to analyze images without the need for any manual measurement, potentially removing intra- and inter-user variability for more consistent results.

  8. Medical ultrasound imaging

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2007-01-01

    The paper gives an introduction to current medical ultrasound imaging systems. The basics of anatomic and blood flow imaging are described. The properties of medical ultrasound and its focusing are described, and the various methods for two- and three-dimensional imaging of the human anatomy...

  9. Chest-wall thickness and percent thoracic fat estimation by B-mode ultrasound: system and procedure review

    International Nuclear Information System (INIS)

    Berger, C.D.; Lane, B.H.; Dunsmore, M.R.

    1983-02-01

    Accurate measurement of chest wall thickness is necessary for estimation of lung burden of transuranic elements in humans. To achieve tis capability, the ORNL Whole Body Counter has acquired a B-mode ultrasonic imaging system for defining the structure within the thorax of the body. This report contains a review of the ultrasound system in use at the ORNL Whole Body Counter, including its theory of operation, and te procedure for use of the system. Future developmental plans are also presented

  10. Prototyping a Hybrid Cooperative and Tele-robotic Surgical System for Retinal Microsurgery.

    Science.gov (United States)

    Balicki, Marcin; Xia, Tian; Jung, Min Yang; Deguet, Anton; Vagvolgyi, Balazs; Kazanzides, Peter; Taylor, Russell

    2011-06-01

    This paper presents the design of a tele-robotic microsurgical platform designed for development of cooperative and tele-operative control schemes, sensor based smart instruments, user interfaces and new surgical techniques with eye surgery as the driving application. The system is built using the distributed component-based cisst libraries and the Surgical Assistant Workstation framework. It includes a cooperatively controlled EyeRobot2, a da Vinci Master manipulator, and a remote stereo visualization system. We use constrained optimization based virtual fixture control to provide Virtual Remote-Center-of-Motion (vRCM) and haptic feedback. Such system can be used in a hybrid setup, combining local cooperative control with remote tele-operation, where an experienced surgeon can provide hand-over-hand tutoring to a novice user. In another scheme, the system can provide haptic feedback based on virtual fixtures constructed from real-time force and proximity sensor information.

  11. Practice-based interpretation of ultrasound studies leads the way to more effective clinical support and less pharmaceutical and surgical intervention for breastfeeding infants.

    Science.gov (United States)

    Douglas, Pamela; Geddes, Donna

    2018-03-01

    breastfeeding optimises health outcomes for both mothers and infants. Although most women want to breastfeed, they report commencing infant formula because of nipple pain, unsettled infant behaviour, and infant growth concerns. To date, existing approaches to fit and hold ('latch and positioning') have been demonstrated not to help breastfeeding outcomes, and women report widespread dissatisfaction with the quality of support and conflicting advice they receive. Breast and nipple pain, difficulty with latching and sucking, fussing at the breast, back-arching, marathon feeds, excessively frequent feeds, poor weight gain, breast refusal, and crying due to poor satiety often signal suboptimal positional instability and impaired milk transfer, but may be misdiagnosed as medical conditions. Over the past two decades, there has been an exponential increase in numbers of infants being treated with medications, laser or scissors frenotomy, and manual therapy for unsettled behaviour and breastfeeding difficulty. New approaches to clinical breastfeeding support are urgently required. we analyse the findings of a literature search of PubMed and MEDLINE databases for ultrasound studies measuring sucking in term and preterm infants. The findings demonstrate that the Stripping Action Model of infant suck during breastfeeding, and the resultant Structural Model of infant suck dysfunction, are inaccurate. Instead, ultrasound data demonstrates the critical role of intra-oral vacuum for milk transfer. We integrate these two-dimensional ultrasound results with clinical experience of the third dimension, volume, to propose a Gestalt Model of the biomechanics of healthy infant suck during breastfeeding. The Gestalt Model hypothesises that optimal intra-oral vacuums and breast tissue volumes are achieved when mother-infant positional stability eliminates conflicting intra-oral vectors, resulting in pain-free, effective milk transfer. the Gestalt Model of the biomechanics of healthy

  12. Ultrasound lung comets: new echographic sign of lung interstitial fibrosis in systemic sclerosis

    Directory of Open Access Journals (Sweden)

    C. Giacomelli

    2011-09-01

    Full Text Available Objective: Interstitial lung disease (ILD and pulmonary arterial hypertension (PAH are common complications of systemic sclerosis (SSc. Echocardiography evaluates PAH, and chest sonography detects even mild ILC as ultrasound lung comets (ULC, i.e. multiple comet-tails fanning out from the lung surface and originating from subpleural interlobular septa thickened by fibrosis. Aim: to assess ILaD and PAH by integrated cardiac and chest ultrasound in SSc. Methods: We enrolled 30 consecutive SSc patients (age= 54±13 years, 23 females in the Rheumatology Clinic of Pisa University. In all, we assessed systolic pulmonary arterial pressure (SPAP, from maximal velocity of tricuspid regurgitation flow, and ULC score with chest sonography (summing the number of ULC from each scanning space of anterior and posterior right and left chest, from second to fifth intercostal space. All patients underwent plasma assay for anti-topoisomerase antibodies (anti-Scl70, and antiicentromere associated with development of pulmonary involvement. Twenty-eight patients also underwent high resolution computed tomography, HRCT (from 0= no fibrosis to 3= honey combing. Results: ULC number - but not SPAP - was correlated to HRCT fibrosis and presence Scl-70 antibodies. ULC number was similar in localized or diffuse forms (16±20 vs 21±19, p=ns and was unrelated to SPAP (r=0.216, p=ns. Conclusions: Chest sonography assessment and ULC allow a complete, simple, radiation-free characterization of interstitial lung involvement in SSc - all in one setting and with the same instrument, same transducer and the same sonographer. In particular, ULC number is associated with HRCT evidence of lung fibrosis and presence of Scl-70 antibodies.

  13. Lens subluxation grading system: predictive value for ectopia lentis surgical outcomes

    OpenAIRE

    Mauro Waiswol; Niro Kasahara

    2009-01-01

    Objective: To present a classification system to grade ectopia lentis and to assess its usefulness as a predictor for surgical outcomes. Methods: Fifty-one eyes of 28 patients with either simple (19 patients) or Marfan syndrome-associated ectopia lentis (nine patients) with variable degrees of subluxation were operated on. Lens subluxation intensity was graded according to the lens subluxation grading system (LSGS) from grade 1 (lens on the whole pupillary area) up to grade 4 (lens absent fro...

  14. Treatment delivery software for a new clinical grade ultrasound system for thermoradiotherapy.

    Science.gov (United States)

    Novák, Petr; Moros, Eduardo G; Straube, William L; Myerson, Robert J

    2005-11-01

    A detailed description of a clinical grade Scanning Ultrasound Reflector Linear Array System (SURLAS) applicator was given in a previous paper [Med. Phys. 32, 230-240 (2005)]. In this paper we concentrate on the design, development, and testing of the personal computer (PC) based treatment delivery software that runs the therapy system. The SURLAS requires the coordinated interaction between the therapy applicator and several peripheral devices for its proper and safe operation. One of the most important tasks was the coordination of the input power sequences for the elements of two parallel opposed ultrasound arrays (eight 1.5 cm x 2 cm elements/array, array 1 and 2 operate at 1.9 and 4.9 MHz, respectively) in coordination with the position of a dual-face scanning acoustic reflector. To achieve this, the treatment delivery software can divide the applicator's treatment window in up to 64 sectors (minimum size of 2 cm x 2 cm), and control the power to each sector independently by adjusting the power output levels from the channels of a 16-channel radio-frequency generator. The software coordinates the generator outputs with the position of the reflector as it scans back and forth between the arrays. Individual sector control and dual frequency operation allows the SURLAS to adjust power deposition in three dimensions to superficial targets coupled to its treatment window. The treatment delivery software also monitors and logs several parameters such as temperatures acquired using a 16-channel thermocouple thermometry unit. Safety (in particular to patients) was the paramount concern and design criterion. Failure mode and effects analysis (FMEA) was applied to the applicator as well as to the entire therapy system in order to identify safety issues and rank their relative importance. This analysis led to the implementation of several safety mechanisms and a software structure where each device communicates with the controlling PC independently of the others. In case

  15. Open-source, small-animal magnetic resonance-guided focused ultrasound system.

    Science.gov (United States)

    Poorman, Megan E; Chaplin, Vandiver L; Wilkens, Ken; Dockery, Mary D; Giorgio, Todd D; Grissom, William A; Caskey, Charles F

    2016-01-01

    MR-guided focused ultrasound or high-intensity focused ultrasound (MRgFUS/MRgHIFU) is a non-invasive therapeutic modality with many potential applications in areas such as cancer therapy, drug delivery, and blood-brain barrier opening. However, the large financial costs involved in developing preclinical MRgFUS systems represent a barrier to research groups interested in developing new techniques and applications. We aim to mitigate these challenges by detailing a validated, open-source preclinical MRgFUS system capable of delivering thermal and mechanical FUS in a quantifiable and repeatable manner under real-time MRI guidance. A hardware and software package was developed that includes closed-loop feedback controlled thermometry code and CAD drawings for a therapy table designed for a preclinical MRI scanner. For thermal treatments, the modular software uses a proportional integral derivative controller to maintain a precise focal temperature rise in the target given input from MR phase images obtained concurrently. The software computes the required voltage output and transmits it to a FUS transducer that is embedded in the delivery table within the magnet bore. The delivery table holds the FUS transducer, a small animal and its monitoring equipment, and a transmit/receive RF coil. The transducer is coupled to the animal via a water bath and is translatable in two dimensions from outside the magnet. The transducer is driven by a waveform generator and amplifier controlled by real-time software in Matlab. MR acoustic radiation force imaging is also implemented to confirm the position of the focus for mechanical and thermal treatments. The system was validated in tissue-mimicking phantoms and in vivo during murine tumor hyperthermia treatments. Sonications were successfully controlled over a range of temperatures and thermal doses for up to 20 min with minimal temperature overshoot. MR thermometry was validated with an optical temperature probe, and focus

  16. A Portable Shoulder-Mounted Camera System for Surgical Education in Spine Surgery.

    Science.gov (United States)

    Pham, Martin H; Ohiorhenuan, Ifije E; Patel, Neil N; Jakoi, Andre M; Hsieh, Patrick C; Acosta, Frank L; Wang, Jeffrey C; Liu, John C

    2017-02-07

    The past several years have demonstrated an increased recognition of operative videos as an important adjunct for resident education. Currently lacking, however, are effective methods to record video for the purposes of illustrating the techniques of minimally invasive (MIS) and complex spine surgery. We describe here our experiences developing and using a shoulder-mounted camera system for recording surgical video. Our requirements for an effective camera system included wireless portability to allow for movement around the operating room, camera mount location for comfort and loupes/headlight usage, battery life for long operative days, and sterile control of on/off recording. With this in mind, we created a shoulder-mounted camera system utilizing a GoPro™ HERO3+, its Smart Remote (GoPro, Inc., San Mateo, California), a high-capacity external battery pack, and a commercially available shoulder-mount harness. This shoulder-mounted system was more comfortable to wear for long periods of time in comparison to existing head-mounted and loupe-mounted systems. Without requiring any wired connections, the surgeon was free to move around the room as needed. Over the past several years, we have recorded numerous MIS and complex spine surgeries for the purposes of surgical video creation for resident education. Surgical videos serve as a platform to distribute important operative nuances in rich multimedia. Effective and practical camera system setups are needed to encourage the continued creation of videos to illustrate the surgical maneuvers in minimally invasive and complex spinal surgery. We describe here a novel portable shoulder-mounted camera system setup specifically designed to be worn and used for long periods of time in the operating room.

  17. Improved automated lumen contour detection by novel multifrequency processing algorithm with current intravascular ultrasound system.

    Science.gov (United States)

    Kume, Teruyoshi; Kim, Byeong-Keuk; Waseda, Katsuhisa; Sathyanarayana, Shashidhar; Li, Wenguang; Teo, Tat-Jin; Yock, Paul G; Fitzgerald, Peter J; Honda, Yasuhiro

    2013-02-01

    The aim of this study was to evaluate a new fully automated lumen border tracing system based on a novel multifrequency processing algorithm. We developed the multifrequency processing method to enhance arterial lumen detection by exploiting the differential scattering characteristics of blood and arterial tissue. The implementation of the method can be integrated into current intravascular ultrasound (IVUS) hardware. This study was performed in vivo with conventional 40-MHz IVUS catheters (Atlantis SR Pro™, Boston Scientific Corp, Natick, MA) in 43 clinical patients with coronary artery disease. A total of 522 frames were randomly selected, and lumen areas were measured after automatically tracing lumen borders with the new tracing system and a commercially available tracing system (TraceAssist™) referred to as the "conventional tracing system." The data assessed by the two automated systems were compared with the results of manual tracings by experienced IVUS analysts. New automated lumen measurements showed better agreement with manual lumen area tracings compared with those of the conventional tracing system (correlation coefficient: 0.819 vs. 0.509). When compared against manual tracings, the new algorithm also demonstrated improved systematic error (mean difference: 0.13 vs. -1.02 mm(2) ) and random variability (standard deviation of difference: 2.21 vs. 4.02 mm(2) ) compared with the conventional tracing system. This preliminary study showed that the novel fully automated tracing system based on the multifrequency processing algorithm can provide more accurate lumen border detection than current automated tracing systems and thus, offer a more reliable quantitative evaluation of lumen geometry. Copyright © 2011 Wiley Periodicals, Inc.

  18. Lens subluxation grading system: predictive value for ectopia lentis surgical outcomes

    Directory of Open Access Journals (Sweden)

    Mauro Waiswol

    2009-03-01

    Full Text Available Objective: To present a classification system to grade ectopia lentis and to assess its usefulness as a predictor for surgical outcomes. Methods: Fifty-one eyes of 28 patients with either simple (19 patients or Marfan syndrome-associated ectopia lentis (nine patients with variable degrees of subluxation were operated on. Lens subluxation intensity was graded according to the lens subluxation grading system (LSGS from grade 1 (lens on the whole pupillary area up to grade 4 (lens absent from the pupillary area. Thirty eyes underwent cataract extraction (“dry” aspiration with endocapsular ring and in-the-bag intraocular lens (IOL implantation. Twenty-one eyes underwent cataract extraction (“dry” aspiration with scleral fixation of the IOL. The predictive value of the LSGS was assessed by analyzing the post-operative outcomes, including visual acuity (VA, endothelial cell loss, and complications for each grade on the grading system. Rresults: Patients were classified into grade 1 (19.6%, grade 2 (51% and grade 3 (29.4%. Post-operative VA was lower for eyes with larger degrees of subluxation. The higher the subluxation grade, the higher the endothelial cell loss, as well as, the frequency of vitreous loss and surgical time. Higher subluxation grades prevented optimal surgical outcomes with endocapsular ring and in-the-bag IOL implantation. Cconclusions: The LSGS provides an estimate of the surgical success of ectopia lentis. Adequate standardization of lens subluxation is crucial for understanding studies dealing with the surgical correction of this disorder.

  19. Single-use surgical clothing system for reduction of airborne bacteria in the operating room.

    Science.gov (United States)

    Tammelin, A; Ljungqvist, B; Reinmüller, B

    2013-07-01

    It is desirable to maintain a low bacterial count in the operating room air to prevent surgical site infection. This can be achieved by ventilation or by all staff in the operating room wearing clothes made from low-permeable material (i.e. clean air suits). We investigated whether there was a difference in protective efficacy between a single-use clothing system made of polypropylene and a reusable clothing system made of a mixed material (cotton/polyester) by testing both in a dispersal chamber and during surgical procedures. Counts of colony-forming units (cfu)/m(3) air were significantly lower when using the single-use clothing system in both settings. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ... pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic organs early ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... size, shape and consistency (whether the object is solid or filled with fluid). In medicine, ultrasound is ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... pictures of a man’s prostate gland and to help diagnose symptoms such as difficulty urinating or an ... Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. Prostate ultrasound, ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams also help identify: ... fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ultrasound or ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. There are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... There are three types of pelvic ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams ... are three types of pelvic ultrasound: abdominal ( transabdominal ) vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the procedure? In women, a pelvic ultrasound is most often performed to evaluate the: uterus cervix ovaries ... page How is the procedure performed? Transabdominal: For most ultrasound exams, you will be positioned lying face- ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is used to evaluate the: bladder seminal vesicles prostate Transrectal ultrasound, a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ultrasound transducer into ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Obstetric Ultrasound Ultrasound - Prostate Kidney and Bladder Stones Abnormal Vaginal Bleeding ... questions or for a referral to a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use ... procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view the endometrium (the lining of the uterus) and the ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ... abnormal masses, such as tumors. In an ultrasound examination, a transducer both sends the sound waves into ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... needles are used to extract a sample of cells from organs for laboratory testing. Doppler ultrasound images ... ultrasound, measures the direction and speed of blood cells as they move through vessels. The movement of ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ... structure and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging uses no ionizing radiation. Ultrasound scanning ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ... sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... help to distract the child and make the time pass quickly. The ultrasound exam room may have ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ... bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the prostate gland because ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Imaging? Ultrasound waves are disrupted by air or gas; therefore ultrasound is not an ideal imaging technique ... page Additional Information and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... ultrasound images are captured in real-time, they can show the structure and movement of the body's ... Because ultrasound provides real-time images, it also can be used to guide procedures such as needle ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? Ultrasound exams in which the transducer ... in the sperm or urine following the procedure. After an ultrasound examination, you should be able to ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... investigation of the uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries ... abnormal uterine bleeding Some physicians also use 3-D ultrasound or sonohysterography for patients with infertility. In ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and produces pictures of the inside of the body using sound waves. Ultrasound imaging, also called ultrasound ... from the probe through the gel into the body. The transducer collects the sounds that bounce back ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  7. Obstetrical Ultrasound

    Science.gov (United States)

    ... heartbeat can be seen as an ongoing ultrasound movie. Ultrasound devices also use Doppler, a special application ... the possible charges you will incur. Web page review process: This Web page is reviewed regularly by ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Sonohysterography Ultrasound - ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... menstrual problems Ultrasound exams also help identify: palpable masses such as ovarian cysts and uterine fibroids ovarian ... In children, pelvic ultrasound can help evaluate: pelvic masses pelvic pain ambiguous genitalia and anomalies of pelvic ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive, and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is safe, noninvasive and does not use ionizing radiation. This procedure requires little to no special preparation. ... create an image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and development of an embryo or fetus during pregnancy. See the Obstetrical Ultrasound page for more information . ... object is solid or filled with fluid). In medicine, ultrasound is used to detect changes in appearance, ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... most ultrasound exams, you will be positioned lying face-up on an examination table that can be ... region of the prostate. A biopsy will add time to the procedure. If a Doppler ultrasound study ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound: abdominal, vaginal (for women), and rectal (for men). These exams are frequently used to evaluate the ... vaginal ( transvaginal / endovaginal ) for women rectal ( transrectal ) for men A Doppler ultrasound exam may be part of ...

  15. Ultraino: An Open Phased-Array System for Narrowband Airborne Ultrasound Transmission.

    Science.gov (United States)

    Marzo, Asier; Corkett, Tom; Drinkwater, Bruce W

    2018-01-01

    Modern ultrasonic phased-array controllers are electronic systems capable of delaying the transmitted or received signals of multiple transducers. Configurable transmit-receive array systems, capable of electronic steering and shaping of the beam in near real-time, are available commercially, for example, for medical imaging. However, emerging applications, such as ultrasonic haptics, parametric audio, or ultrasonic levitation, require only a small subset of the capabilities provided by the existing controllers. To meet this need, we present Ultraino, a modular, inexpensive, and open platform that provides hardware, software, and example applications specifically aimed at controlling the transmission of narrowband airborne ultrasound. Our system is composed of software, driver boards, and arrays that enable users to quickly and efficiently perform research in various emerging applications. The software can be used to define array geometries, simulate the acoustic field in real time, and control the connected driver boards. The driver board design is based on an Arduino Mega and can control 64 channels with a square wave of up to 17 Vpp and /5 phase resolution. Multiple boards can be chained together to increase the number of channels. The 40-kHz arrays with flat and spherical geometries are demonstrated for parametric audio generation, acoustic levitation, and haptic feedback.

  16. Local Gene Delivery System by Bubble Liposomes and Ultrasound Exposure into Joint Synovium

    Directory of Open Access Journals (Sweden)

    Yoichi Negishi

    2011-01-01

    Full Text Available Recently, we have developed novel polyethylene glycol modified liposomes (bubble liposomes; BL entrapping an ultrasound (US imaging gas, which can work as a gene delivery tool with US exposure. In this study, we investigated the usefulness of US-mediated gene transfer systems with BL into synoviocytes in vitro and joint synovium in vivo. Highly efficient gene transfer could be achieved in the cultured primary synoviocytes transfected with the combination of BL and US exposure, compared to treatment with plasmid DNA (pDNA alone, pDNA plus BL, or pDNA plus US. When BL was injected into the knee joints of mice, and US exposure was applied transcutaneously to the injection site, highly efficient gene expression could be observed in the knee joint transfected with the combination of BL and US exposure, compared to treatment with pDNA alone, pDNA plus BL, or pDNA plus US. The localized and prolonged gene expression was also shown by an in vivo luciferase imaging system. Thus, this local gene delivery system into joint synovium using the combination of BL and US exposure may be an effective means for gene therapy in joint disorders.

  17. 3D optical imagery for motion compensation in a limb ultrasound system

    Science.gov (United States)

    Ranger, Bryan J.; Feigin, Micha; Zhang, Xiang; Mireault, Al; Raskar, Ramesh; Herr, Hugh M.; Anthony, Brian W.

    2016-04-01

    Conventional processes for prosthetic socket fabrication are heavily subjective, often resulting in an interface to the human body that is neither comfortable nor completely functional. With nearly 100% of amputees reporting that they experience discomfort with the wearing of their prosthetic limb, designing an effective interface to the body can significantly affect quality of life and future health outcomes. Active research in medical imaging and biomechanical tissue modeling of residual limbs has led to significant advances in computer aided prosthetic socket design, demonstrating an interest in moving toward more quantifiable processes that are still patient-specific. In our work, medical ultrasonography is being pursued to acquire data that may quantify and improve the design process and fabrication of prosthetic sockets while greatly reducing cost compared to an MRI-based framework. This paper presents a prototype limb imaging system that uses a medical ultrasound probe, mounted to a mechanical positioning system and submerged in a water bath. The limb imaging is combined with three-dimensional optical imaging for motion compensation. Images are collected circumferentially around the limb and combined into cross-sectional axial image slices, resulting in a compound image that shows tissue distributions and anatomical boundaries similar to magnetic resonance imaging. In this paper we provide a progress update on our system development, along with preliminary results as we move toward full volumetric imaging of residual limbs for prosthetic socket design. This demonstrates a novel multi-modal approach to residual limb imaging.

  18. Positioning device for MRI-guided high intensity focused ultrasound system

    Energy Technology Data Exchange (ETDEWEB)

    Damianou, Christakis [Frederick Institute of Technology (FIT), Limassol (Cyprus); MEDSONIC, LTD, Limassol (Cyprus); Ioannides, Kleanthis [Polikliniki Igia, Limassol (Cyprus); Milonas, Nicos [Frederick Institute of Technology (FIT), Limassol (Cyprus)

    2008-04-15

    A prototype magnetic resonance imaging (MRI)- compatible positioning device was used to move an MRI-guided high intensity focused ultrasound (HIFU) transducer. The positioning device has three user-controlled degrees of freedom that allow access to various targeted lesions. The positioning device was designed and fabricated using construction materials selected for compatibility with high magnetic fields and fast switching magnetic field gradients encountered inside MRI scanners. The positioning device incorporates only MRI compatible materials such as piezoelectric motors, plastic sheets, brass screws, plastic pulleys and timing belts. The HIFU/MRI system includes the multiple subsystems (a) HIFU system, (b) MR imaging, (c) Positioning device (robot) and associate drivers, (d) temperature measurement, (e) cavitation detection, (f) MRI compatible camera, and (g) Soft ware. The MRI compatibility of the system was successfully demonstrated in a clinical high-field MRI scanner. The ability of the robot to accurately move the transducer thus creating discrete and overlapping lesions in biological tissue was tested successfully. A simple, cost effective, portable positioning device has been developed which can be used in virtually any clinical MRI scanner since it can be sited on the scanner's table. The propagation of HIFU can use either a lateral or superior-inferior approach. Discrete and large lesions were created successfully with reproducible results. (orig.)

  19. A novel ultrasound-guided shoulder arthroscopic surgery

    Science.gov (United States)

    Tyryshkin, K.; Mousavi, P.; Beek, M.; Chen, T.; Pichora, D.; Abolmaesumi, P.

    2006-03-01

    This paper presents a novel ultrasound-guided computer system for arthroscopic surgery of the shoulder joint. Intraoperatively, the system tracks and displays the surgical instruments, such as arthroscope and arthroscopic burrs, relative to the anatomy of the patient. The purpose of this system is to improve the surgeon's perception of the three-dimensional space within the anatomy of the patient in which the instruments are manipulated and to provide guidance towards the targeted anatomy. Pre-operatively, computed tomography images of the patient are acquired to construct virtual threedimensional surface models of the shoulder bone structure. Intra-operatively, live ultrasound images of pre-selected regions of the shoulder are captured using an ultrasound probe whose three-dimensional position is tracked by an optical camera. These images are used to register the surface model to the anatomy of the patient in the operating room. An initial alignment is obtained by matching at least three points manually selected on the model to their corresponding points identified on the ultrasound images. The registration is then improved with an iterative closest point or a sequential least squares estimation technique. In the present study the registration results of these techniques are compared. After the registration, surgical instruments are displayed relative to the surface model of the patient on a graphical screen visible to the surgeon. Results of laboratory experiments on a shoulder phantom indicate acceptable registration results and sufficiently fast overall system performance to be applicable in the operating room.

  20. Application of Ultrasound in a Closed System: Optimum Condition for Antioxidants Extraction of Blackberry (Rubus fructicosus) Residues.

    Science.gov (United States)

    Zafra-Rojas, Quinatzin Y; Cruz-Cansino, Nelly S; Quintero-Lira, Aurora; Gómez-Aldapa, Carlos A; Alanís-García, Ernesto; Cervantes-Elizarrarás, Alicia; Güemes-Vera, Norma; Ramírez-Moreno, Esther

    2016-07-21

    Blackberry processing generates up to 20% of residues composed mainly of peel, seeds and pulp that are abundant in flavonoids. The objective of this study was to optimize the ultrasound conditions, in a closed system, for antioxidants extraction, using the response surface methodology. Blackberry (Rubus fructicosus) residues were analyzed for total phenolics, total anthocyanins, and antioxidant activity by ABTS and DPPH. The selected independent variables were ultrasound amplitude (X₁: 80%-90%) and extraction time (X₂: 10-15 min), and results were compared with conventional extraction methods. The optimal conditions for antioxidants extraction were 91% amplitude for 15 min. The results for total phenolic content and anthocyanins and antioxidant activity by ABTS and DPPH were of 1201.23 mg gallic acid equivalent (GAE)/100 g dry weight basis (dw); 379.12 mg/100 g·dw; 6318.98 µmol Trolox equivalent (TE)/100 g·dw and 9617.22 µmol TE/100 g·dw, respectively. Compared to solvent extraction methods (water and ethanol), ultrasound achieved higher extraction of all compounds except for anthocyanins. The results obtained demonstrated that ultrasound is an alternative to improve extraction yield of antioxidants from fruit residues such as blackberry.

  1. New real-time MR image-guided surgical robotic system for minimally invasive precision surgery

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, M.; Yasunaga, T.; Konishi, K. [Kyushu University, Department of Advanced Medical Initiatives, Faculty of Medical Sciences, Fukuoka (Japan); Tanoue, K.; Ieiri, S. [Kyushu University Hospital, Department of Advanced Medicine and Innovative Technology, Fukuoka (Japan); Kishi, K. [Hitachi Ltd, Mechanical Engineering Research Laboratory, Hitachinaka-Shi, Ibaraki (Japan); Nakamoto, H. [Hitachi Medical Corporation, Application Development Office, Kashiwa-Shi, Chiba (Japan); Ikeda, D. [Mizuho Ikakogyo Co. Ltd, Tokyo (Japan); Sakuma, I. [The University of Tokyo, Graduate School of Engineering, Bunkyo-Ku, Tokyo (Japan); Fujie, M. [Waseda University, Graduate School of Science and Engineering, Shinjuku-Ku, Tokyo (Japan); Dohi, T. [The University of Tokyo, Graduate School of Information Science and Technology, Bunkyo-Ku, Tokyo (Japan)

    2008-04-15

    To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D navigation and 2-D ISC images, as well as the MR-compatible laparoscope. The ISC image was updated every 4 s; no artifact was detected. A newly developed MR image-guided surgical robotic system is feasible for an operator to perform safe and precise minimally invasive procedures. (orig.)

  2. New real-time MR image-guided surgical robotic system for minimally invasive precision surgery

    International Nuclear Information System (INIS)

    Hashizume, M.; Yasunaga, T.; Konishi, K.; Tanoue, K.; Ieiri, S.; Kishi, K.; Nakamoto, H.; Ikeda, D.; Sakuma, I.; Fujie, M.; Dohi, T.

    2008-01-01

    To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe was monitored continuously with 3-D navigation and 2-D ISC images, as well as the MR-compatible laparoscope. The ISC image was updated every 4 s; no artifact was detected. A newly developed MR image-guided surgical robotic system is feasible for an operator to perform safe and precise minimally invasive procedures. (orig.)

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... transducer sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of Pelvic Ultrasound Imaging? Ultrasound waves are ...

  4. A compact mechatronic system for 3D ultrasound guided prostate interventions

    International Nuclear Information System (INIS)

    Bax, Jeffrey; Smith, David; Bartha, Laura; Montreuil, Jacques; Sherebrin, Shi; Gardi, Lori; Edirisinghe, Chandima; Fenster, Aaron

    2011-01-01

    Purpose: Ultrasound imaging has improved the treatment of prostate cancer by producing increasingly higher quality images and influencing sophisticated targeting procedures for the insertion of radioactive seeds during brachytherapy. However, it is critical that the needles be placed accurately within the prostate to deliver the therapy to the planned location and avoid complications of damaging surrounding tissues. Methods: The authors have developed a compact mechatronic system, as well as an effective method for guiding and controlling the insertion of transperineal needles into the prostate. This system has been designed to allow guidance of a needle obliquely in 3D space into the prostate, thereby reducing pubic arch interference. The choice of needle trajectory and location in the prostate can be adjusted manually or with computer control. Results: To validate the system, a series of experiments were performed on phantoms. The 3D scan of the string phantom produced minimal geometric error, which was less than 0.4 mm. Needle guidance accuracy tests in agar prostate phantoms showed that the mean error of bead placement was less then 1.6 mm along parallel needle paths that were within 1.2 mm of the intended target and 1 deg. from the preplanned trajectory. At oblique angles of up to 15 deg. relative to the probe axis, beads were placed to within 3.0 mm along a trajectory that were within 2.0 mm of the target with an angular error less than 2 deg. Conclusions: By combining 3D TRUS imaging system to a needle tracking linkage, this system should improve the physician's ability to target and accurately guide a needle to selected targets without the need for the computer to directly manipulate and insert the needle. This would be beneficial as the physician has complete control of the system and can safely maneuver the needle guide around obstacles such as previously placed needles.

  5. 3D ultrasound system to investigate intraventricular hemorrhage in preterm neonates

    International Nuclear Information System (INIS)

    Kishimoto, J; Lawrence, K St; De Ribaupierre, S; Fenster, A; Lee, D S C; Mehta, R

    2013-01-01

    Intraventricular hemorrhage (IVH) is a common disorder among preterm neonates that is routinely diagnosed and monitored by 2D cranial ultrasound (US). The cerebral ventricles of patients with IVH often have a period of ventricular dilation (ventriculomegaly). This initial increase in ventricle size can either spontaneously resolve, which often shows clinically as a period of stabilization in ventricle size and eventual decline back towards a more normal size, or progressive ventricular dilation that does not stabilize and which may require interventional therapy to reduce symptoms relating to increased intracranial pressure. To improve the characterization of ventricle dilation, we developed a 3D US imaging system that can be used with a conventional clinical US scanner to image the ventricular system of preterm neonates at risk of ventriculomegaly. A motorized transducer housing was designed specifically for hand-held use inside an incubator using a transducer commonly used for cranial 2D US scans. This system was validated using geometric phantoms, US/MRI compatible ventricle volume phantoms, and patient images to determine 3D reconstruction accuracy and inter- and intra-observer volume estimation variability. 3D US geometric reconstruction was found to be accurate with an error of 3 for a single observer. Results from ANOVA for three observers segmenting three patients of IVH grade II did not show any significant differences (p > 0.05) for the measured ventricle volumes between observers. This 3D US system can reliably produce 3D US images of the neonatal ventricular system. There is the potential to use this system to monitor the progression of ventriculomegaly over time in patients with IVH. (paper)

  6. [Mobile hospital -real time mobile telehealthcare system with ultrasound and CT van using high-speed satellite communication-].

    Science.gov (United States)

    Takizawa, Masaomi; Miyashita, Toyohisa; Murase, Sumio; Kanda, Hirohito; Karaki, Yoshiaki; Yagi, Kazuo; Ohue, Toru

    2003-01-01

    A real-time telescreening system is developed to detect early diseases for rural area residents using two types of mobile vans with a portable satellite station. The system consists of a satellite communication system with 1.5Mbps of the JCSAT-1B satellite, a spiral CT van, an ultrasound imaging van with two video conference system, a DICOM server and a multicast communication unit. The video image and examination image data are transmitted from the van to hospitals and the university simultaneously. Physician in the hospital observes and interprets exam images from the van and watches the video images of the position of ultrasound transducer on screenee in the van. After the observation images, physician explains a results of the examination by the video conference system. Seventy lung CT screening and 203 ultrasound screening were done from March to June 2002. The trial of this real time screening suggested that rural residents are given better healthcare without visit to the hospital. And it will open the gateway to reduce the medical cost and medical divide between city area and rural area.

  7. Photoacoustic cystography using handheld dual modal clinical ultrasound photoacoustic imaging system

    Science.gov (United States)

    Sivasubramanian, Kathyayini; Periyasamy, Vijitha; Austria, Dienzo Rhonnie; Pramanik, Manojit

    2018-02-01

    Vesicoureteral reflux is the abnormal flow of urine from your bladder back up the tubes (ureters) that connect your kidneys to your bladder. Normally, urine flows only down from your kidneys to your bladder. Vesicoureteral reflux is usually diagnosed in infants and children. The disorder increases the risk of urinary tract infections, which, if left untreated, can lead to kidney damage. X-Ray cystography is used currently to diagnose this condition which uses ionising radiation, making it harmful for patients. In this work we demonstrate the feasibility of imaging the urinary bladder using a handheld clinical ultrasound and photoacoustic dual modal imaging system in small animals (rats). Additionally, we demonstrate imaging vesicoureteral reflux using bladder mimicking phantoms. Urinary bladder imaging is done with the help of contrast agents like black ink and gold nanoparticles which have high optical absorption at 1064 nm. Imaging up to 2 cm was demonstrated with this system. Imaging was done at a framerate of 5 frames per second.

  8. Combined Scanning Confocal Ultrasound Diagnostic and Treatment System for Bone Quality Assessment and Fracture Healing

    Data.gov (United States)

    National Aeronautics and Space Administration — The objectives of this study are to develop a combined diagnostic and treatment ultrasound technology for early prediction of bone disorder and guided acceleration...

  9. First steps towards ultrasound-based motion compensation for imaging and therapy: calibration with an optical system and 4D PET imaging

    Directory of Open Access Journals (Sweden)

    Julia eSchwaab

    2015-11-01

    Full Text Available Target motion, particularly in the abdomen, due to respiration or patient movement is still a challenge in many diagnostic and therapeutic processes. Hence, methods to detect and compensate this motion are required. Diagnostic ultrasound represents a non-invasive and dose-free alternative to fluoroscopy, providing more information about internal target motion than respiration belt or optical tracking.The goal of this project is to develop an ultrasound based motion tracking for real time motion correction in radiation therapy and diagnostic imaging, notably in 4D positron emission tomography (PET. In this work, a workflow is established to enable the transformation of ultrasound tracking data to the coordinates of the treatment delivery or imaging system – even if the ultrasound probe is moving due to respiration. It is shown that the ultrasound tracking signal is equally adequate for 4D PET image reconstruction as the clinically used respiration belt and provides additional opportunities in this concern. Furthermore, it is demonstrated that the ultrasound probe being within the PET field of view generally has no relevant influence on the image quality. The accuracy and precision of all the steps in the calibration workflow for ultrasound tracking based 4D PET imaging are found to be in an acceptable range for clinical implementation. Eventually, we show in vitro that an ultrasound based motion tracking in absolute room coordinates with a moving US-transducer is feasible.

  10. Superficial ultrasound shear wave speed measurements in soft and hard elasticity phantoms: repeatability and reproducibility using two ultrasound systems.

    Science.gov (United States)

    Dillman, Jonathan R; Chen, Shigao; Davenport, Matthew S; Zhao, Heng; Urban, Matthew W; Song, Pengfei; Watcharotone, Kuanwong; Carson, Paul L

    2015-03-01

    There is a paucity of data available regarding the repeatability and reproducibility of superficial shear wave speed (SWS) measurements at imaging depths relevant to the pediatric population. To assess the repeatability and reproducibility of superficial shear wave speed measurements acquired from elasticity phantoms at varying imaging depths using three imaging methods, two US systems and multiple operators. Soft and hard elasticity phantoms manufactured by Computerized Imaging Reference Systems Inc. (Norfolk, VA) were utilized for our investigation. Institution No. 1 used an Acuson S3000 US system (Siemens Medical Solutions USA, Malvern, PA) and three shear wave imaging method/transducer combinations, while institution No. 2 used an Aixplorer US system (SuperSonic Imagine, Bothell, WA) and two different transducers. Ten stiffness measurements were acquired from each phantom at three depths (1.0 cm, 2.5 cm and 4.0 cm) by four operators at each institution. Student's t-test was used to compare SWS measurements between imaging techniques, while SWS measurement agreement was assessed with two-way random effects single-measure intra-class correlation coefficients (ICCs) and coefficients of variation. Mixed model regression analysis determined the effect of predictor variables on SWS measurements. For the soft phantom, the average of mean SWS measurements across the various imaging methods and depths was 0.84 ± 0.04 m/s (mean ± standard deviation) for the Acuson S3000 system and 0.90 ± 0.02 m/s for the Aixplorer system (P = 0.003). For the hard phantom, the average of mean SWS measurements across the various imaging methods and depths was 2.14 ± 0.08 m/s for the Acuson S3000 system and 2.07 ± 0.03 m/s Aixplorer system (P > 0.05). The coefficients of variation were low (0.5-6.8%), and interoperator agreement was near-perfect (ICCs ≥ 0.99). Shear wave imaging method and imaging depth significantly affected measured SWS (P

  11. Computer-aided diagnostic system for detection of Hashimoto thyroiditis on ultrasound images from a Polish population.

    Science.gov (United States)

    Acharya, U Rajendra; Sree, S Vinitha; Krishnan, M Muthu Rama; Molinari, Filippo; Zieleźnik, Witold; Bardales, Ricardo H; Witkowska, Agnieszka; Suri, Jasjit S

    2014-02-01

    Computer-aided diagnostic (CAD) techniques aid physicians in better diagnosis of diseases by extracting objective and accurate diagnostic information from medical data. Hashimoto thyroiditis is the most common type of inflammation of the thyroid gland. The inflammation changes the structure of the thyroid tissue, and these changes are reflected as echogenic changes on ultrasound images. In this work, we propose a novel CAD system (a class of systems called ThyroScan) that extracts textural features from a thyroid sonogram and uses them to aid in the detection of Hashimoto thyroiditis. In this paradigm, we extracted grayscale features based on stationary wavelet transform from 232 normal and 294 Hashimoto thyroiditis-affected thyroid ultrasound images obtained from a Polish population. Significant features were selected using a Student t test. The resulting feature vectors were used to build and evaluate the following 4 classifiers using a 10-fold stratified cross-validation technique: support vector machine, decision tree, fuzzy classifier, and K-nearest neighbor. Using 7 significant features that characterized the textural changes in the images, the fuzzy classifier had the highest classification accuracy of 84.6%, sensitivity of 82.8%, specificity of 87.0%, and a positive predictive value of 88.9%. The proposed ThyroScan CAD system uses novel features to noninvasively detect the presence of Hashimoto thyroiditis on ultrasound images. Compared to manual interpretations of ultrasound images, the CAD system offers a more objective interpretation of the nature of the thyroid. The preliminary results presented in this work indicate the possibility of using such a CAD system in a clinical setting after evaluating it with larger databases in multicenter clinical trials.

  12. Load evaluation of the da Vinci surgical system for transoral robotic surgery.

    Science.gov (United States)

    Fujiwara, Kazunori; Fukuhara, Takahiro; Niimi, Koji; Sato, Takahiro; Kitano, Hiroya

    2015-12-01

    Transoral robotic surgery, performed with the da Vinci surgical system (da Vinci), is a surgical approach for benign and malignant lesions of the oral cavity and laryngopharynx. It provides several unique advantages, which include a 3-dimensional magnified view and ability to see and work around curves or angles. However, the current da Vinci surgical system does not provide haptic feedback. This is problematic because the potential risks specific to the transoral use of the da Vinci include tooth injury, mucosal laceration, ocular injury and mandibular fracture. To assess the potential for intraoperative injuries, we measured the load of the endoscope and the instrument of the da Vinci Si surgical system. We pressed the endoscope and instrument of the da Vinci Si against Load cell six times each and measured the dynamic load and the time-to-maximum load. We also struck the da Vinci Si endoscope and instrument against the Load cell six times each and measured the impact load. The maximum dynamic load was 7.27 ± 1.31 kg for the endoscope and 1.90 ± 0.72 for the instrument. The corresponding time-to-maximum loads were 1.72 ± 0.22 and 1.29 ± 0.34 s, but the impact loads were significantly lower than the dynamic load. It remains possible that a major load is exerted on adjacent structures by continuous contact with the endoscope and instrument of da Vinci Si. However, there is a minor delay in reaching the maximum load. Careful monitoring by an on-site assistant may, therefore, help prevent contiguous injury.

  13. Application of a drug delivery system using ultrasound and nano/microbubbles for anti-angiogenic therapy

    International Nuclear Information System (INIS)

    Horie, Sachiko; Kodama, Tetsuya; Sato, Yasushi

    2017-01-01

    The drug delivery system using ultrasound and nano/microbubbles is a molecular delivery approach using the mechanism of sonoporation. With sonoporation, an endothelium-derived negative-feedback regulator of angiogenesis, Vasohibin-1 (VASH1), was introduced specifically into tumor vessels. We found VASH1 in tumor vessels induce normalization of tumor vessels and inhibited tumor growth. A recent topic regarding tumor angiogenesis is vascular normalization. Tumor vessels are abnormal or immature that cause hyperpermeability and impaired blood flow. Tumor vascular normalization improves blood flow and tissue hypoxia, which increase the effectiveness of chemotherapy and radiotherapy and reduce tumor cell malignancy. In this review, application of drug delivery system using ultrasound for an anti-angiogenic therapy, a tumor vessel normalization therapy to treat cancer, is summarized. (author)

  14. Stone fragmentation by ultrasound

    Indian Academy of Sciences (India)

    Unknown

    In the present work, enhancement of the kidney stone fragmentation by using ultrasound is studied. The cavi- ... ment system like radiation pressure balance, the power is given by ... Thus the bubble size has direct relationship with its life and.

  15. Application of the ultrasound hyperthermia model for a multi-layered tissue system

    International Nuclear Information System (INIS)

    Loerincz, A

    2004-01-01

    This work models the thermal effect of several planar transducers targeting the tumour interactively in a ceramics-coupling-skin-muscle-tumour system. The most important inputs of the model include the following: emitted electric output, J/s; mechanical efficiency, %; number of transducers, pieces; surface area of the transducer, m 2 ; area, m 2 and temperature, K of the cooling surface, attenuation coefficients, Np/cm MHz; specific heats, J/gK; densities, g/cm 3 ; heat conductivities, J/msK; sound velocities m/s; flow rate of blood in the tissues, ml/gtissue/min; sound path in the tissues and in the blood flowing through the tissues, m. From the inputs, a number of intermediate data are determined, e.g. the geometry of the irradiated bodies that are in the path of ultrasound, acoustic hardness, Pas/m; sound reflection and sound transmission occurring at the interfaces, Np; heat exchanger wall thickness of the irradiated bodies, m; heat dissipation and heat exchanger surface areas, m 2 ; flow rate of blood in the tissues located in the path of ultrasound, ml/tissue mass in g/min; and the sound attenuation of the tissues, Np. The amount of generated heat, K/s decreased by the heat energy transported, J/s to the surrounding tissues by blood and heat conductivity, and the actual temperature, K of the irradiated tissue are the output parameters calculated by the model. The output results are available in the form of functions. The expected temperature of the target area, K can be set to either the denaturation temperature or to the respiratory decomposition temperature (43.5 deg. C) without damaging the surrounding tissues by setting in the following parameters properly: electric output power, W; the number and surface area, m 2 of the transducers; the area, m 2 and temperature, K of the cooling surfaces. After further development, the model will be suitable for handling more than three tissue layers, increased blood flow rates different angles of incidence, and

  16. Extracranial Carotid Artery Stenting in Surgically High-Risk Patients Using the Carotid Wallstent Endoprosthesis:Midterm Clinical and Ultrasound Follow-Up Results

    International Nuclear Information System (INIS)

    Maleux, Geert; Bernaerts, Pauwel; Thijs, Vincent; Daenens, Kim; Vaninbroukx, Johan; Fourneau, Inge; Nevelsteen, Andre

    2003-01-01

    The purpose of this study was to evaluate the feasibility, safety and midterm outcome of elective implantation of the Carotid Wallstent (registered) in patients considered to be at high surgical risk. In a prospective study, 54 carotid artery stenoses in 51 patients were stented over a 24-month period. Three patients underwent bilateral carotid artery stenting. Institutional inclusion criteria for invasive treatment of carotid occlusive disease (carotid endarterectomy or carotid artery stenting) are patients presenting with a 70% or more symptomatic stenosis and those with an 80% or more asymptomatic stenosis having a life-expectancy of more than 1 year. All patients treated by carotid artery stenting were considered at high risk for carotid endarterectomy because of a hostile neck (17 patients-31.5%) or because of severe comorbidities (37 patients-68.5%). No cerebral protection device was used. Of the 54 lesions, 33 (61.1%) were symptomatic and 21 (38.8%) were asymptomatic. Follow-up was performed by physical examination and by duplex ultrasonography at 1 month, 6 months, 1 year and 2 years after the procedure. All 54 lesions could be stented successfully without periprocedural stroke. Advert events during follow-up (mean 13.9 ± 5.7 months) were non-stroke-related death in 6 patients (11.1%), minor stroke in 4 stented hemispheres(7.4%), transient ipsilateral facial pain in 1 patient (1.8%),infection of the stented surgical patch in 1 patient (1.8%) and asymptomatic in stent restenosis in 4 patients (7.4%). The percutaneous implantation of the Carotid Wallstent (registered) , even without cerebral protection device, appears to be a safe procedure with acceptable clinical and ultrasonographic follow-up results in patients at high surgical risk. But some late adverse events such as ipsilateral recurrence of non-disabling (minor) stroke or in stent restenosis still remain real challenging problems

  17. Application of a uniform anatomic grading system to measure disease severity in eight emergency general surgical illnesses.

    Science.gov (United States)

    Crandall, Marie L; Agarwal, Suresh; Muskat, Peter; Ross, Steven; Savage, Stephanie; Schuster, Kevin; Tominaga, Gail T; Shafi, Shahid

    2014-11-01

    Emergent general surgical diseases encompass a broad spectrum of anatomy and pathophysiology, creating challenges for outcomes assessment, research, and surgical training. The goal of this study was to measure anatomic disease severity for eight emergent general surgical diseases using the uniform grading system of the American Association for the Surgery of Trauma (AAST). The Committee on Patient Assessment and Outcomes of AAST applied the previously developed uniform grading system to eight emergent general surgical diseases using a consensus of experts. It was then reviewed and approved by the Board of Managers of AAST. Severity grades for eight commonly encountered emergent general surgical conditions were created: breast abscess, esophageal perforation, infectious colitis, pelvic inflammatory disease, perirectal abscess, pleural space infections, soft tissue infections, and surgical site infections. The range of grades from I through V, reflect progression from mild disease, limited to within the organ itself, to widespread severe disease. This article provides a uniform grading system for measuring anatomic severity of eight emergent general surgical diseases. Consistent adoption of these grades could improve standardization for quality assurance, outcomes research, and surgical training.

  18. Hemodynamic behavior modeling of a Virtual Surgical Patient based on a Fuzzy Expert System.

    Directory of Open Access Journals (Sweden)

    Paulo Farias Paiva

    2016-07-01

    Full Text Available The Virtual Reality (VR allows its users to experience a sense of being immersed in synthetic 3D scenarios generated by computer graphics. The so-called Virtual Environments (VEs based on RV can be applied to medical education, enabling: repetitive training and the development of psychomotor skills in surgical procedures without compromising real patients. Surgical simulators that feature Dynamic Virtual Patients (VPs, that is, reacts physiologically to interventions and medical decisions made during the training. These systems present more realism while it offers the possibility of varying clinical cases. This work has as main objective to discuss important issues of modeling the hemodynamic performance of a VP, specifically to simulate blood pressure values (both sistolic and diastolic variables. The model of a VP is presented as result as well as is presented an architecture for its integration to simulators based on VR.

  19. The effect of a robot-assisted surgical system on the kinematics of user movements.

    Science.gov (United States)

    Nisky, Ilana; Hsieh, Michael H; Okamura, Allison M

    2013-01-01

    Teleoperated robot-assisted surgery (RAS) offers many advantages over traditional minimally invasive surgery. However, RAS has not yet realized its full potential, and it is not clear how to optimally train surgeons to use these systems. We hypothesize that the dynamics of the master manipulator impact the ability of users to make desired movements with the robot. We compared freehand and teleoperated movements of novices and experienced surgeons. To isolate the effects of dynamics from procedural knowledge, we chose simple movements rather than surgical tasks. We found statistically significant effects of teleoperation and user expertise in several aspects of motion, including target acquisition error, movement speed, and movement smoothness. Such quantitative assessment of human motor performance in RAS can impact the design of surgical robots, their control, and surgeon training methods, and eventually, improve patient outcomes.

  20. The utilization of an ultrasound-guided 8-gauge vacuum-assisted breast biopsy system as an innovative approach to accomplishing complete eradication of multiple bilateral breast fibroadenomas

    Directory of Open Access Journals (Sweden)

    Povoski Stephen P

    2007-10-01

    Full Text Available Abstract Background Ultrasound-guided vacuum-assisted breast biopsy technology is extremely useful for diagnostic biopsy of suspicious breast lesions and for attempted complete excision of appropriately selected presumed benign breast lesions. Case presentation A female patient presented with 16 breast lesions (eight within each breast, documented on ultrasound and all presumed to be fibroadenomas. Over a ten and one-half month period of time, 14 of these 16 breast lesions were removed under ultrasound guidance during a total of 11 separate 8-gauge Mammotome® excision procedures performed during seven separate sessions. Additionally, two of these 16 breast lesions were removed by open surgical excision. A histopathologic diagnosis of fibroadenoma and/or fibroadenomatous changes was confirmed at all lesion excision sites. Interval follow-up ultrasound imaging revealed no evidence of a residual lesion at the site of any of the 16 original breast lesions. Conclusion This report describes an innovative approach of utilizing ultrasound-guided 8-gauge vacuum-assisted breast biopsy technology for assisting in achieving complete eradication of multiple bilateral fibroadenomas in a patient who presented with 16 documented breast lesions. As such, this innovative approach is highly recommended in similar appropriately selected patients.

  1. Evaluation of a microfocused ultrasound system for improving skin laxity and tightening in the lower face.

    Science.gov (United States)

    Oni, Georgette; Hoxworth, Ron; Teotia, Sumeet; Brown, Spencer; Kenkel, Jeffrey M

    2014-09-01

    The Ulthera System (Ulthera, Inc, Mesa, Arizona) employs microfocused ultrasound to cause discrete focal heating of the dermis and stimulate neocollagenesis and elastin remodeling. The authors investigated tightening and lifting of cheek tissue, improvement in jawline definition, and reduction in submental skin laxity in patients treated with the Ulthera System. A total of 103 adults were enrolled in this prospective nonrandomized clinical trial. Three-dimensional photographs obtained at baseline and 3 months posttreatment were assessed qualitatively by 3 blinded reviewers and quantitatively with AutoCAD software (Informer Technologies, Redwood City, California). The relationship between outcomes and body mass index (BMI) was examined as well. Patients rated pain during the procedure and provided subjective assessment of their outcome at 90 days. Adverse events were documented. Ninety-three patients were evaluated. Blinded reviewers observed improvement in skin laxity in 58.1% of patients. During quantitative assessments, overall improvement in skin laxity was noted in 63.6% of evaluated patients. No change was detected in 54.5% of patients whose BMI exceeded 30 kg/m2 or in 12.2% of patients whose BMI was ≤30 kg/m2. At day 90, 65.6% of patients perceived improvement in the skin laxity of the lower half of their face/neck. The average procedural pain scores for the cheek, submental, and submandibular regions were 5.68, 6.09, and 6.53, respectively. Wheals, which resolved without intervention or long-term sequelae, were reported for 3 patients. To the authors' knowledge, this is the largest clinical study of the effectiveness of the Ulthera System for rejuvenation of the lower face. At day 90, improvements were reported by two-thirds of patients and by nearly 60% of blinded reviewers. Outcomes were better in patients with BMI≤30 kg/m2. 2. © 2014 The American Society for Aesthetic Plastic Surgery, Inc.

  2. [Successful treatment of surgically induced necrotizing sclerokeratitis (SINS) with systemic immunosuppresive agents and amniotic membrane grafting].

    Science.gov (United States)

    Cordero-Coma, M; Franco-Benito, M; García-Ruiz-de-Morales, J M; Alonso-Orcajo, N; Del Barrio-Manso, I

    2009-11-01

    We report the case of a 74-year-old female who developed a necrotizing sclerokeratitis affecting her left eye after uncomplicated cataract surgery. She had no previous history of systemic autoimmune disease. Histopathology of the lesion revealed necrotic granulomatosis with an increased number of plasma cells. Surgically induced necrotizing sclerokeratitis (SINS) is a serious entity which requires prompt and aggressive therapy to prevent its potential devastating ocular consequences. Conjunctival resection and amniotic membrane grafting may be necessary to temporarily interrupt local immunologic events in severe cases. However, associated systemic immunomodulatory therapy seems to be mandatory (Arch Soc Esp Oftalmol 2009; 84: 577-580).

  3. Prostate ultrasound imaging: evaluation of a two-step scoring system in the diagnosis of prostate cancer.

    Science.gov (United States)

    Gao, Yong; Liao, Xin-Hong; Ma, Yan; Lu, Lu; Wei, Li-Yan; Yan, Xue

    2017-12-01

    This study aims to investigate the feasibility and performance of a two-step scoring system of ultrasound imaging in the diagnosis of prostate cancer. 75 patients with 888 consecutive histopathologically verified lesions were included in this study. Step 1, an initial 5-point scoring system was developed based on conventional transrectal ultrasound (TRUS). Step 2, a final scoring system was evaluated according to contrast-enhanced transrectal ultrasound (CE-TRUS). Each lesion was evaluated using the two-step scoring system (step 1 + step 2) and compared with only using conventional TRUS (step 1). 888 lesions were histologically verified: 315 of them were prostate cancer from 46 patients and 573 were benign prostatic hypertrophy (BPH) from 29 patients. According to the two-step scoring system, 284 lesions were upgraded and 130 lesions were downgraded from step 1 to step 2 (this means using step 2 to assess the results by step 1). However, 96 cases were improperly upgraded after step 2 and 48 malignant lesions were still missed after step 2 as score-1. For the two-step scoring system, the sensitivity, specificity, and accuracy were 84.7%, 83.2%, and 83.7%, respectively, versus 22.8%, 96.6%, and 70.4%, respectively, for conventional TRUS. The area under the ROC curve (AUC) for lesion diagnosis was 0.799-0.952 for the two-step scoring system, versus 0.479-0.712 for conventional TRUS. The difference in the diagnostic accuracy of the two-step scoring system and conventional TRUS was statistically significant (Pstep scoring system was straightforward to use and achieved a considerably accurate diagnostic performance for prostate cancer. The application of the two-step scoring system for prostate cancer is promising.

  4. Implementation and utility of a daily ultrasound-based localization system with intensity-modulated radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Morr, Jody; DiPetrillo, Thomas; Tsai, J.-S.; Engler, Mark; Wazer, David E. MD.

    2002-01-01

    Purpose: To evaluate the clinical feasibility of daily computer-assisted transabdominal ultrasonography for target position verification in the setting of intensity-modulated radiotherapy (IMRT) for prostate cancer. Methods and Materials: Twenty-three patients with clinically localized prostate cancer were treated using a sequential tomotherapy IMRT technique (Peacock) and daily computer-assisted transabdominal ultrasonography (BAT) for target localization. Patients were instructed to maintain a full bladder and were placed in the supine position using triangulation tattoos and a leg immobilizer to minimize pelvic rotation. The BAT ultrasound system is docked to the treatment collimator and electronically imports the CT simulation target contours and isocenter. The system is able to use the machine isocenter as a reference point to overlay the corresponding CT contours onto the ultrasound images captured in the transverse and sagittal planes. A touch screen menu is used to maneuver the CT contours in three dimensions such that they match the ultrasound images. The system then displays the three-dimensional couch shifts required to produce field alignment. Data were prospectively collected to measure the frequency by which useful ultrasound images were obtained, the amount of time required for localization/setup, and the direction/magnitude of the positional adjustments. Results: Of the 23 patients, the BAT ultrasound system produced images of sufficient quality to perform the overlay of the CT contours in 19 patients such that positional verification could be reliably performed. Poor image quality was associated with patient inability to maintain a full bladder, large body habitus, or other anatomic constraints. Of the 19 assessable patients, a total of 185 treatment alignments were performed (mean 8.8/patient). For all cases, the average time required for the daily ultrasound imaging and positional adjustments was 11.9 min. After the initial 5 cases, the user

  5. PMO Delivery System Using Bubble Liposomes and Ultrasound Exposure for Duchenne Muscular Dystrophy Treatment.

    Science.gov (United States)

    Negishi, Yoichi; Ishii, Yuko; Nirasawa, Kei; Sasaki, Eri; Endo-Takahashi, Yoko; Suzuki, Ryo; Maruyama, Kazuo

    2018-01-01

    Duchenne muscular dystrophy (DMD) is a genetic disorder characterized by progressive muscle degeneration, caused by nonsense or frameshift mutations in the dystrophin (DMD) gene. Antisense oligonucleotides can be used to induce specific exon skipping; recently, a phosphorodiamidate morpholino oligomer (PMO) has been approved for clinical use in DMD. However, an efficient PMO delivery strategy is required to improve the therapeutic efficacy in DMD patients. We previously developed polyethylene glycol (PEG)-modified liposomes containing ultrasound contrast gas, "Bubble liposomes" (BLs), and found that the combination of BLs with ultrasound exposure is a useful gene delivery tool. Here, we describe an efficient PMO delivery strategy using the combination of BLs and ultrasound exposure to treat muscles in a DMD mouse model (mdx). This ultrasound-mediated BL technique can increase the PMO-mediated exon-skipping efficiency, leading to significantly increased dystrophin expression. Thus, the combination of BLs and ultrasound exposure may be a feasible PMO delivery method to improve therapeutic efficacy and reduce the PMO dosage for DMD treatment.

  6. Treatment time reduction for large thermal lesions by using a multiple 1D ultrasound phased array system

    International Nuclear Information System (INIS)

    Liu, H.-L.; Chen, Y.-Y.; Yen, J.-Y.; Lin, W.-L.

    2003-01-01

    To generate large thermal lesions in ultrasound thermal therapy, cooling intermissions are usually introduced during the treatment to prevent near-field heating, which leads to a long treatment time. A possible strategy to shorten the total treatment time is to eliminate the cooling intermissions. In this study, the two methods, power optimization and acoustic window enlargement, for reducing power accumulation in the near field are combined to investigate the feasibility of continuously heating a large target region (maximally 3.2 x 3.2 x 3.2 cm 3 ). A multiple 1D ultrasound phased array system generates the foci to scan the target region. Simulations show that the target region can be successfully heated without cooling and no near-field heating occurs. Moreover, due to the fact that there is no cooling time during the heating sessions, the total treatment time is significantly reduced to only several minutes, compared to the existing several hours

  7. Using value-based analysis to influence outcomes in complex surgical systems.

    Science.gov (United States)

    Kirkpatrick, John R; Marks, Stanley; Slane, Michele; Kim, Donald; Cohen, Lance; Cortelli, Michael; Plate, Juan; Perryman, Richard; Zapas, John

    2015-04-01

    Value-based analysis (VBA) is a management strategy used to determine changes in value (quality/cost) when a usual practice (UP) is replaced by a best practice (BP). Previously validated in clinical initiatives, its usefulness in complex systems is unknown. To answer this question, we used VBA to correct deficiencies in cardiac surgery at Memorial Healthcare System. Cardiac surgery is a complex surgical system that lends itself to VBA because outcomes metrics provided by the Society of Thoracic Surgeons provide an estimate of quality; cost is available from Centers for Medicare and Medicaid Services and other contemporary sources; the UP can be determined; and the best practice can be established. Analysis of the UP at Memorial Healthcare System revealed considerable deficiencies in selection of patients for surgery; the surgery itself, including choice of procedure and outcomes; after care; follow-up; and control of expenditures. To correct these deficiencies, each UP was replaced with a BP. Changes included replacement of most of the cardiac surgeons; conversion to an employed physician model; restructuring of a heart surgery unit; recruitment of cardiac anesthesiologists; introduction of an interactive educational program; eliminating unsafe practices; and reducing cost. There was a significant (p value (quality/cost) in a complex surgical system. Copyright © 2015 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Design and Performance Evaluation of Real-time Endovascular Interventional Surgical Robotic System with High Accuracy.

    Science.gov (United States)

    Wang, Kundong; Chen, Bing; Lu, Qingsheng; Li, Hongbing; Liu, Manhua; Shen, Yu; Xu, Zhuoyan

    2018-05-15

    Endovascular interventional surgery (EIS) is performed under a high radiation environment at the sacrifice of surgeons' health. This paper introduces a novel endovascular interventional surgical robot that aims to reduce radiation to surgeons and physical stress imposed by lead aprons during fluoroscopic X-ray guided catheter intervention. The unique mechanical structure allowed the surgeon to manipulate the axial and radial motion of the catheter and guide wire. Four catheter manipulators (to manipulate the catheter and guide wire), and a control console which consists of four joysticks, several buttons and two twist switches (to control the catheter manipulators) were presented. The entire robotic system was established on a master-slave control structure through CAN (Controller Area Network) bus communication, meanwhile, the slave side of this robotic system showed highly accurate control over velocity and displacement with PID controlling method. The robotic system was tested and passed in vitro and animal experiments. Through functionality evaluation, the manipulators were able to complete interventional surgical motion both independently and cooperatively. The robotic surgery was performed successfully in an adult female pig and demonstrated the feasibility of superior mesenteric and common iliac artery stent implantation. The entire robotic system met the clinical requirements of EIS. The results show that the system has the ability to imitate the movements of surgeons and to accomplish the axial and radial motions with consistency and high-accuracy. Copyright © 2018 John Wiley & Sons, Ltd.

  9. Study on real-time force feedback for a master-slave interventional surgical robotic system.

    Science.gov (United States)

    Guo, Shuxiang; Wang, Yuan; Xiao, Nan; Li, Youxiang; Jiang, Yuhua

    2018-04-13

    In robot-assisted catheterization, haptic feedback is important, but is currently lacking. In addition, conventional interventional surgical robotic systems typically employ a master-slave architecture with an open-loop force feedback, which results in inaccurate control. We develop herein a novel real-time master-slave (RTMS) interventional surgical robotic system with a closed-loop force feedback that allows a surgeon to sense the true force during remote operation, provide adequate haptic feedback, and improve control accuracy in robot-assisted catheterization. As part of this system, we also design a unique master control handle that measures the true force felt by a surgeon, providing the basis for the closed-loop control of the entire system. We use theoretical and empirical methods to demonstrate that the proposed RTMS system provides a surgeon (using the master control handle) with a more accurate and realistic force sensation, which subsequently improves the precision of the master-slave manipulation. The experimental results show a substantial increase in the control accuracy of the force feedback and an increase in operational efficiency during surgery.

  10. Surgical clothing systems in laminar airflow operating room: a numerical assessment.

    Science.gov (United States)

    Sadrizadeh, Sasan; Holmberg, Sture

    2014-01-01

    This study compared two different laminar airflow distribution strategies - horizontal and vertical - and investigated the effectiveness of both ventilation systems in terms of reducing the sedimentation and distribution of bacteria-carrying particles. Three different staff clothing systems, which resulted in source strengths of 1.5, 4 and 5 CFU/s per person, were considered. The exploration was conducted numerically using a computational fluid dynamics technique. Active and passive air sampling methods were simulated in addition to recovery tests, and the results were compared. Model validation was performed through comparisons with measurement data from the published literature. The recovery test yielded a value of 8.1 min for the horizontal ventilation scenario and 11.9 min for the vertical ventilation system. Fewer particles were captured by the slit sampler and in sedimentation areas with the horizontal ventilation system. The simulated results revealed that under identical conditions in the examined operating room, the horizontal laminar ventilation system performed better than the vertical option. The internal constellation of lamps, the surgical team and objects could have a serious effect on the movement of infectious particles and therefore on postoperative surgical site infections. Copyright © 2014 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  11. Image-Guided Surgical Robotic System for Percutaneous Reduction of Joint Fractures.

    Science.gov (United States)

    Dagnino, Giulio; Georgilas, Ioannis; Morad, Samir; Gibbons, Peter; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2017-11-01

    Complex joint fractures often require an open surgical procedure, which is associated with extensive soft tissue damages and longer hospitalization and rehabilitation time. Percutaneous techniques can potentially mitigate these risks but their application to joint fractures is limited by the current sub-optimal 2D intra-operative imaging (fluoroscopy) and by the high forces involved in the fragment manipulation (due to the presence of soft tissue, e.g., muscles) which might result in fracture malreduction. Integration of robotic assistance and 3D image guidance can potentially overcome these issues. The authors propose an image-guided surgical robotic system for the percutaneous treatment of knee joint fractures, i.e., the robot-assisted fracture surgery (RAFS) system. It allows simultaneous manipulation of two bone fragments, safer robot-bone fixation system, and a traction performing robotic manipulator. This system has led to a novel clinical workflow and has been tested both in laboratory and in clinically relevant cadaveric trials. The RAFS system was tested on 9 cadaver specimens and was able to reduce 7 out of 9 distal femur fractures (T- and Y-shape 33-C1) with acceptable accuracy (≈1 mm, ≈5°), demonstrating its applicability to fix knee joint fractures. This study paved the way to develop novel technologies for percutaneous treatment of complex fractures including hip, ankle, and shoulder, thus representing a step toward minimally-invasive fracture surgeries.

  12. Development and Assessment of Memorial Sloan Kettering Cancer Center’s Surgical Secondary Events Grading System

    Science.gov (United States)

    Strong, Vivian E.; Selby, Luke V.; Sovel, Mindy; Disa, Joseph J.; Hoskins, William; DeMatteo, Ronald; Scardino, Peter; Jaques, David P.

    2015-01-01

    Background Studying surgical secondary events is an evolving effort with no current established system for database design, standard reporting, or definitions. Using the Clavien-Dindo classification as a guide, in 2001 we developed a Surgical Secondary Events database based on grade of event and required intervention to begin prospectively recording and analyzing all surgical secondary events (SSE). Study Design Events are prospectively entered into the database by attending surgeons, house staff, and research staff. In 2008 we performed a blinded external audit of 1,498 operations that were randomly selected to examine the quality and reliability of the data. Results 1,498 of 4,284 operations during the 3rd quarter of 2008 were audited. 79% (N=1,180) of the operations did not have a secondary event while 21% (N=318) of operations had an identified event. 91% (1,365) of operations were correctly entered into the SSE database. 97% (129/133) of missed secondary events were Grades I and II. Three Grade III (2%) and one Grade IV (1%) secondary event were missed. There were no missed Grade 5 secondary events. Conclusion Grade III – IV events are more accurately collected than Grade I – II events. Robust and accurate secondary events data can be collected by clinicians and research staff and these data can safely be used for quality improvement projects and research. PMID:25319579

  13. Ultrasound-guided renal biopsy: experience using an automated core biopsy system.

    Science.gov (United States)

    Chan, R; Common, A A; Marcuzzi, D

    2000-04-01

    To assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy using an automated core biopsy system, and to determine radiologists' accuracy in predicting sample adequacy. Ninety-five biopsies were performed on 25 native kidneys and 70 renal allografts using a 16-gauge automated, spring-loaded core biopsy device under real-time sonographic guidance. Radiologists performing the biopsy estimated the number of core samples needed to obtain an adequate specimen, based on visual inspection of each core. The final determination of the number of samples was made by a pathology technologist who attended each biopsy, based on preliminary microscopic examination of tissue cores. After each biopsy, an ultrasonographic examination was performed to search for biopsy-related hemorrhage, and a questionnaire was given to the patient to determine biopsy-related complications, which were categorized as either minor or major. The main indication for biopsy was acute renal failure (in 43.2% of biopsies). An average of 3 tissue cores per biopsy were obtained. Of the 94 patients in whom a biopsy was conducted to exclude diffuse renal disease, a mean of 12.5 glomeruli were present in each specimen. Overall, adequate tissue for diagnosis was obtained in 98.9% of cases. The radiologists' estimate of the number of core samples needed concurred with the pathology technologists' determination of sample adequacy in 88.4% of cases. A total of 26 complications occurred (in 27.4% of biopsies), consisting of 23 minor (24.2%) and 3 major (3.2%) complications. Real-time sonographic guidance in conjunction with an automated core biopsy system is a safe and accurate method of performing percutaneous renal biopsy. Routine use of sonographic examinations to search for biopsy-related complications is not indicated. Radiologists are accurate in estimating sample adequacy in most cases; however, the presence of a pathology technologist at the biopsy procedure virtually eliminates the

  14. Effectiveness of the Thoracic Pedicle Screw Placement Using the Virtual Surgical Training System: A Cadaver Study.

    Science.gov (United States)

    Hou, Yang; Lin, Yanping; Shi, Jiangang; Chen, Huajiang; Yuan, Wen

    2018-03-14

    The virtual simulation surgery has initially exhibited its promising potentials in neurosurgery training. To evaluate effectiveness of the Virtual Surgical Training System (VSTS) on novice residents placing thoracic pedicle screws in a cadaver study. A total of 10 inexperienced residents participated in this study and were randomly assigned to 2 groups. The group using VSTS to learn thoracic pedicle screw fixation was the simulation training (ST) group and the group receiving an introductory teaching session was the control group. Ten fresh adult spine specimens including 6 males and 4 females with a mean age of 58.5 yr (range: 33-72) were collected and randomly allocated to the 2 groups. After exposing anatomic structures of thoracic spine, the bilateral pedicle screw placement of T6-T12 was performed on each cadaver specimen. The postoperative computed tomography scan was performed on each spine specimen, and experienced observers independently reviewed the placement of the pedicle screws to assess the incidence of pedicle breach. The screw penetration rates of the ST group (7.14%) was significantly lower in comparison to the control group (30%, P < .05). Statistically significant difference in acceptable rates of screws also occurred between the ST (100%) and control (92.86%) group (P < .05). In addition, the average screw penetration distance in control group (2.37 mm ± 0.23 mm) was significantly greater than ST group (1.23 mm ± 0.56 mm, P < .05). The virtual reality surgical training of thoracic pedicle screw instrumentation effectively improves surgical performance of novice residents compared to those with traditional teaching method, and can help new beginners to master the surgical technique within shortest period of time.

  15. Intraoperative registered transrectal ultrasound guidance for robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Mohareri, Omid; Ischia, Joseph; Black, Peter C; Schneider, Caitlin; Lobo, Julio; Goldenberg, Larry; Salcudean, Septimiu E

    2015-01-01

    To provide unencumbered real-time ultrasound image guidance during robot-assisted laparoscopic radical prostatectomy, we developed a robotic transrectal ultrasound system that tracks the da Vinci® Surgical System instruments. We describe our initial clinical experience with this system. After an evaluation in a canine model, 20 patients were enrolled in the study. During each procedure the transrectal ultrasound transducer was manually positioned using a brachytherapy stabilizer to provide good imaging of the prostate. Then the transrectal ultrasound was registered to the da Vinci robot by a previously validated procedure. Finally, automatic rotation of the transrectal ultrasound was enabled such that the transrectal ultrasound imaging plane safely tracked the tip of the da Vinci instrument controlled by the surgeon, while real-time transrectal ultrasound images were relayed to the surgeon at the da Vinci console. Tracking was activated during all critical stages of the surgery. The transrectal ultrasound robot was easy to set up and use, adding 7 minutes (range 5 to 14) to the procedure. It did not require an assistant or additional control devices. Qualitative feedback was acquired from the surgeons, who found transrectal ultrasound useful in identifying the urethra while passing the dorsal venous complex suture, defining the prostate-bladder interface during bladder neck dissection, identifying the seminal vesicles and their location with respect to the rectal wall, and identifying the distal prostate boundary at the apex. Real-time, registered robotic transrectal ultrasound guidance with automatic instrument tracking during robot-assisted laparoscopic radical prostatectomy is feasible and potentially useful. The results justify further studies to establish whether the approach can improve procedure outcomes. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  16. Outpatient and Ambulatory Surgery Consumer Assessment of Healthcare Providers and Systems (OAS CAHPS) survey for ambulatory surgical centers - Facility

    Data.gov (United States)

    U.S. Department of Health & Human Services — A list of ambulatory surgical center ratings for the Outpatient and Ambulatory Surgery Consumer Assessment of Healthcare Providers and Systems (OAS CAHPS) survey....

  17. A System-on-Chip Solution for Point-of-Care Ultrasound Imaging Systems: Architecture and ASIC Implementation.

    Science.gov (United States)

    Kang, Jeeun; Yoon, Changhan; Lee, Jaejin; Kye, Sang-Bum; Lee, Yongbae; Chang, Jin Ho; Kim, Gi-Duck; Yoo, Yangmo; Song, Tai-kyong

    2016-04-01

    In this paper, we present a novel system-on-chip (SOC) solution for a portable ultrasound imaging system (PUS) for point-of-care applications. The PUS-SOC includes all of the signal processing modules (i.e., the transmit and dynamic receive beamformer modules, mid- and back-end processors, and color Doppler processors) as well as an efficient architecture for hardware-based imaging methods (e.g., dynamic delay calculation, multi-beamforming, and coded excitation and compression). The PUS-SOC was fabricated using a UMC 130-nm NAND process and has 16.8 GFLOPS of computing power with a total equivalent gate count of 12.1 million, which is comparable to a Pentium-4 CPU. The size and power consumption of the PUS-SOC are 27×27 mm(2) and 1.2 W, respectively. Based on the PUS-SOC, a prototype hand-held US imaging system was implemented. Phantom experiments demonstrated that the PUS-SOC can provide appropriate image quality for point-of-care applications with a compact PDA size ( 200×120×45 mm(3)) and 3 hours of battery life.

  18. Incidence of surgical-site infections and the validity of the National Nosocomial Infections Surveillance System risk index in a general surgical ward in Santa Cruz, Bolivia.

    Science.gov (United States)

    Soleto, Lorena; Pirard, Marianne; Boelaert, Marleen; Peredo, Remberto; Vargas, Reinerio; Gianella, Alberto; Van der Stuyft, Patrick

    2003-01-01

    To estimate the frequency of and risk factors for surgical-site infections (SSIs) in Bolivia, and to study the performance of the National Nosocomial Infections Surveillance (NNIS) System risk index in a developing country. A prospective study with patient follow-up until the 30th postoperative day. A general surgical ward of a public hospital in Santa Cruz, Bolivia. Patients admitted to the ward between July 1998 and June 1999 on whom surgical procedures were performed. Follow-up was complete for 91.5% of 376 surgical procedures. The overall SSI rate was 12%. Thirty-four (75.6%) of the 45 SSIs were culture positive. A logistic regression model retained an American Society of Anesthesiologists score of more than 1 (odds ratio [OR], 1.87), a not-clean wound class (OR, 2.28), a procedure duration of more than 1 hour (OR, 1.81), and drain (OR, 1.98) as independent risk factors for SSI. There was no significant association between the NNIS System risk index and SSI rates. However, a "local" risk index constructed with the above cutoff points showed a linear trend with SSI (P < .001) and a relative risk of 3.18 for risk class 3 versus a class of less than 3. SSIs cause considerable morbidity in Santa Cruz. Appropriate nosocomial infection surveillance and control should be introduced. The NNIS System risk index did not discriminate between patients at low and high risk for SSI in this hospital setting, but a risk score based on local cutoff points performed substantially better.

  19. Assessment of portal venous system patency in the liver transplant candidate: A prospective study comparing ultrasound, microbubble-enhanced colour Doppler ultrasound, with arteriography and surgery

    International Nuclear Information System (INIS)

    Marshall, M.M.; Beese, R.C.; Muiesan, P.; Sarma, D.I.; O'Grady, J.; Sidhu, P.S.

    2002-01-01

    AIM: To determine the role of microbubble-enhanced colour Doppler ultrasound (CDUS) in assessing portal venous patency prior to liver transplantation. MATERIALS AND METHODS: Over a 2-year period, all patients with chronic liver disease undergoing routine pre-transplant CDUS examination in whom the portal venous system was inadequately demonstrated were recruited to the study. CDUS was performed in 368 patients and 33 patients (9%) were recruited. A repeat CDUS examination following an intravenous bolus injection of the microbubble contrast agent Levovist[reg] (Schering Healthcare AG, Berlin, Germany) was performed. Diagnostic confidence was recorded on a free linear analogue scale for both examinations. Findings were compared with indirect portography and surgery. RESULTS: Of the 33 patients with sub-optimal baseline examinations, improvement in portal vein visualization was achieved in 31 patients (94%). Median diagnostic confidence increased from 50% (interquartile range 30-60) to 90% (interquartile range 75-98) (P < 0.001) following administration of Levovist[reg]. Overall accuracy of portal vein assessment using microbubble-enhanced CDUS in 15 patients in whom a definitive diagnosis was made within 2 months was 87%. CONCLUSION: Microbubble-enhanced CDUS is a simple, inexpensive adjunct to standard pre liver transplant screening of the portal vein. It is particularly helpful in patients with end-stage cirrhosis who are at high risk of portal vein thrombosis and in whom the conventional examination is sub-optimal.Marshall, M.M. et al. (2002)

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  1. A high pulse repetition frequency ultrasound system for the ex vivo measurement of mechanical properties of crystalline lenses with laser-induced microbubbles interrogated by acoustic radiation force

    International Nuclear Information System (INIS)

    Yoon, Sangpil; Emelianov, Stanislav; Aglyamov, Salavat; Karpiouk, Andrei

    2012-01-01

    A high pulse repetition frequency ultrasound system for an ex vivo measurement of mechanical properties of an animal crystalline lens was developed and validated. We measured the bulk displacement of laser-induced microbubbles created at different positions within the lens using nanosecond laser pulses. An impulsive acoustic radiation force was applied to the microbubble, and spatio-temporal measurements of the microbubble displacement were assessed using a custom-made high pulse repetition frequency ultrasound system consisting of two 25 MHz focused ultrasound transducers. One of these transducers was used to emit a train of ultrasound pulses and another transducer was used to receive the ultrasound echoes reflected from the microbubble. The developed system was operating at 1 MHz pulse repetition frequency. Based on the measured motion of the microbubble, Young’s moduli of surrounding tissue were reconstructed and the values were compared with those measured using the indentation test. Measured values of Young’s moduli of four bovine lenses ranged from 2.6 ± 0.1 to 26 ± 1.4 kPa, and there was good agreement between the two methods. Therefore, our studies, utilizing the high pulse repetition frequency ultrasound system, suggest that the developed approach can be used to assess the mechanical properties of ex vivo crystalline lenses. Furthermore, the potential of the presented approach for in vivo measurements is discussed. (paper)

  2. The role of robotic surgical system in the management of vascular disease.

    Science.gov (United States)

    Lin, Judith C

    2013-10-01

    The evolution of minimally invasive treatment for aneurysms and occlusive disease has led to the development of endovascular, laparoscopic, and robot-assisted techniques. This article reviews the current literature on the clinical use of robotic surgical systems in the treatment of patients with aneurysms and occlusive disease. A MEDLINE search was performed using the keywords "robotic, vascular, AND surgery." All pertinent articles concerning the use of the robotic surgical system on aneurysms and occlusive disease were reviewed. The author's personal experience consisted of a retrospective review of a prospectively maintained confidential database on all procedures performed with the da Vinci(®) surgical system. Several robot-assisted laparoscopic series on the treatment of aortic disease were identified, including review articles of potential clinical applications in hybrid, laparoscopic vascular, and endovascular treatments for vascular patients using robotic technology. The use of computer-enhanced or robotic technology as a sole modality for bypass of occlusive disease and repair of abdominal aortic, splenic, and renal aneurysms was described in case series with satisfactory patient outcomes. Current robotic endovascular technology was also described. Minimally invasive techniques using endovascular, laparoscopic, or robot-assisted technology have revolutionized the treatment of aortoiliac, splanchnic, and renal aneurysms and occlusive disease. However, robot-assisted techniques for aortic disease may involve a learning curve and increased operating times. Although endovascular therapy is preferred because of faster recovery, this preference for improved short-term outcomes will be balanced with the superiority and durability of robot-assisted endoscopic methods as comparable to open surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Anomalous Systemic Artery to the Left Lower Lobe: Literature Review and a New Surgical Technique.

    Science.gov (United States)

    Miller, Jacob R; Lancaster, Timothy S; Abarbanell, Aaron M; Manning, Peter B; Eghtesady, Pirooz

    2018-05-01

    Anomalous systemic arterial supply to the basal segments of the left lower lobe without coexisting pulmonary artery connection is a rare anomaly. Most feel treatment is necessary; however, the ideal strategy is unclear. Treatments described include embolization, pulmonary resection, or anastomosis to the native pulmonary artery. We recently encountered an infant with this anomaly and present a literature review summarizing all recent reports. Additionally, we describe a novel surgical technique to create a tension-free anastomosis utilizing segmental aortic translocation that we employed in our patient due to a large distance between the anomalous vessel and native left pulmonary artery.

  4. A needle guidance system for biopsy and therapy using two-dimensional ultrasound

    International Nuclear Information System (INIS)

    Bluvol, Nathan; Sheikh, Allison; Kornecki, Anat; Del Rey Fernandez, David; Downey, Donal; Fenster, Aaron

    2008-01-01

    Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsy procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75±0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists

  5. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... inserted into a man's rectum to view the prostate. Transvaginal ultrasound. The transducer is inserted into a ... Stenting Ultrasound-Guided Breast Biopsy Obstetric Ultrasound Ultrasound - Prostate Biopsies - Overview Images related to General Ultrasound Videos ...

  6. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z General Ultrasound Ultrasound imaging uses sound waves to produce ... the limitations of General Ultrasound Imaging? What is General Ultrasound Imaging? Ultrasound is safe and painless, and ...

  7. Diuretic Agent and Normal Saline Infusion Technique for Ultrasound-Guided Percutaneous Nephrostomies in Nondilated Pelvicaliceal Systems

    International Nuclear Information System (INIS)

    Yagci, Cemil; Ustuner, Evren; Atman, Ebru Dusunceli; Baltaci, Sumer; Uzun, Caglar; Akyar, Serdar

    2013-01-01

    Percutaneous nephrostomy (PCN) in a nondilated pelvicaliceal system is technically challenging. We describe an effective method to achieve transient dilatation of the pelvicaliceal system via induction of diuresis using infusion of a diuretic agent in normal saline, therefore allowing easier access to the pelvicaliceal system. Under real-time ultrasound guidance, the technique had been tested in 22 nephrostomies with nondilated system (a total of 20 patients with 2 patients having bilateral nephrostomies) during a 5-year period. Patients were given 40 mg of furosemide in 250 ml of normal saline solution intravenously by rapid infusion. As soon as maximum calyceal dilatation of more than 5 mm was observed, which is usually 15 min later after the end of rapid infusion, patients were positioned obliquely, and PCN procedure under ultrasound guidance was performed. The procedure was successful in 19 of the nephrostomies in 17 patients with a success rate of 86.36 % per procedure and 85 % per patient in nondilated pelvicaliceal systems. No major nephrostomy-, drug-, or technique-related complications were encountered. The technique failed to work in three patients due to the presence of double J catheters and preexisting calyceal perforation which avoided transient dilation of the pelvicaliceal system with diuresis. Diuretic infusion in saline is a feasible and effective method for PCN in nondilated pelvicaliceal systems.

  8. Diuretic Agent and Normal Saline Infusion Technique for Ultrasound-Guided Percutaneous Nephrostomies in Nondilated Pelvicaliceal Systems

    Energy Technology Data Exchange (ETDEWEB)

    Yagci, Cemil, E-mail: cemil.yagci@medicine.ankara.edu.tr; Ustuner, Evren, E-mail: evrenustuner@hotmail.com; Atman, Ebru Dusunceli, E-mail: ebrumd2001@yahoo.com [Ankara University, Department of Radiology, School of Medicine (Turkey); Baltaci, Sumer, E-mail: sbaltaci@hotmail.com [Ankara University, Department of Urology, School of Medicine (Turkey); Uzun, Caglar, E-mail: cuzun77@yahoo.com; Akyar, Serdar, E-mail: yusuf.s.akyar@medicine.ankara.edu.tr [Ankara University, Department of Radiology, School of Medicine (Turkey)

    2013-04-15

    Percutaneous nephrostomy (PCN) in a nondilated pelvicaliceal system is technically challenging. We describe an effective method to achieve transient dilatation of the pelvicaliceal system via induction of diuresis using infusion of a diuretic agent in normal saline, therefore allowing easier access to the pelvicaliceal system. Under real-time ultrasound guidance, the technique had been tested in 22 nephrostomies with nondilated system (a total of 20 patients with 2 patients having bilateral nephrostomies) during a 5-year period. Patients were given 40 mg of furosemide in 250 ml of normal saline solution intravenously by rapid infusion. As soon as maximum calyceal dilatation of more than 5 mm was observed, which is usually 15 min later after the end of rapid infusion, patients were positioned obliquely, and PCN procedure under ultrasound guidance was performed. The procedure was successful in 19 of the nephrostomies in 17 patients with a success rate of 86.36 % per procedure and 85 % per patient in nondilated pelvicaliceal systems. No major nephrostomy-, drug-, or technique-related complications were encountered. The technique failed to work in three patients due to the presence of double J catheters and preexisting calyceal perforation which avoided transient dilation of the pelvicaliceal system with diuresis. Diuretic infusion in saline is a feasible and effective method for PCN in nondilated pelvicaliceal systems.

  9. Surgical Assisting

    Science.gov (United States)

    ... instruction, including: Microbiology Pathophysiology Pharmacology Anatomy and physiology Medical terminology Curriculum . Course content includes: Advanced surgical anatomy Surgical microbiology Surgical pharmacology Anesthesia methods and agents Bioscience Ethical ...

  10. Consumer assessment of healthcare providers and systems surgical care survey: benefits and challenges.

    Science.gov (United States)

    Schulz, Kristine A; Rhee, John S; Brereton, Jean M; Zema, Carla L; Witsell, David L

    2012-10-01

    To describe the feasibility and initial results of the implementation of a continuous quality improvement project using the newly available Consumer Assessment of Healthcare Providers and Systems Surgical Care Survey (S-CAHPS), in a small cohort of otolaryngology-head and neck surgery practices. Prospective observational study using a newly validated health care consumer survey. Two community-based and 2 university-based otolaryngology-head and neck surgery outpatient clinic practices. Fourteen board-certified otolaryngology, head and neck surgeons from 4 practice sites voluntarily participated in this project. All adult patients scheduled for surgery during a 12-month period were asked to complete the S-CAHPS survey through an electronic data capture (EDC) system 7 to 28 days after surgery. The surgeons were not directly involved in administration or collection of survey data. Three sites successfully implemented the S-CAHPS project. A 39.9% response rate was achieved for the cohort of surgical patients entered into the EDC system. While most patients rated their surgeons very high (mean of 9.5 or greater out of 10), subanalysis revealed there is variability among sites and surgeons in communication practices. From these data, a potential surgeon Quality Improvement report was developed that highlights priority areas to improve surgeon-patient rapport. The S-CAHPS survey can be successfully implemented in most otolaryngology practices, and our initial work holds promise for how the survey can be best deployed and analyzed for the betterment of both the surgeon and the patient.

  11. Hybrid procedure for total laryngectomy with a flexible robot-assisted surgical system.

    Science.gov (United States)

    Schuler, Patrick J; Hoffmann, Thomas K; Veit, Johannes A; Rotter, Nicole; Friedrich, Daniel T; Greve, Jens; Scheithauer, Marc O

    2017-06-01

    Total laryngectomy is a standard procedure in head-and-neck surgery for the treatment of cancer patients. Recent clinical experiences have indicated a clinical benefit for patients undergoing transoral robot-assisted total laryngectomy (TORS-TL) with commercially available systems. Here, a new hybrid procedure for total laryngectomy is presented. TORS-TL was performed in human cadavers (n = 3) using a transoral-transcervical hybrid procedure. The transoral approach was performed with a robotic flexible robot-assisted surgical system (Flex®) and compatible flexible instruments. Transoral access and visualization of anatomical landmarks were studied in detail. Total laryngectomy is feasible with a combined transoral-transcervical approach using the flexible robot-assisted surgical system. Transoral visualization of all anatomical structures is sufficient. The flexible design of the robot is advantageous for transoral surgery of the laryngeal structures. Transoral robot assisted surgery has the potential to reduce morbidity, hospital time and fistula rates in a selected group of patients. Initial clinical studies and further development of supplemental tools are in progress. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Intraoperative Ultrasound for Peripheral Nerve Applications.

    Science.gov (United States)

    Willsey, Matthew; Wilson, Thomas J; Henning, Phillip Troy; Yang, Lynda J-S

    2017-10-01

    Offering real-time, high-resolution images via intraoperative ultrasound is advantageous for a variety of peripheral nerve applications. To highlight the advantages of ultrasound, its extraoperative uses are reviewed. The current intraoperative uses, including nerve localization, real-time evaluation of peripheral nerve tumors, and implantation of leads for peripheral nerve stimulation, are reviewed. Although intraoperative peripheral nerve localization has been performed previously using guide wires and surgical dyes, the authors' approach using ultrasound-guided instrument clamps helps guide surgical dissection to the target nerve, which could lead to more timely operations and shorter incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. VR-based training and assessment in ultrasound-guided regional anesthesia: from error analysis to system design.

    LENUS (Irish Health Repository)

    2011-01-01

    If VR-based medical training and assessment is to improve patient care and safety (i.e. a genuine health gain), it has to be based on clinically relevant measurement of performance. Metrics on errors are particularly useful for capturing and correcting undesired behaviors before they occur in the operating room. However, translating clinically relevant metrics and errors into meaningful system design is a challenging process. This paper discusses how an existing task and error analysis was translated into the system design of a VR-based training and assessment environment for Ultrasound Guided Regional Anesthesia (UGRA).

  14. Counterbalancing the use of ultrasound contrast agents by a cavitation-regulated system.

    Science.gov (United States)

    Desjouy, C; Fouqueray, M; Lo, C W; Muleki Seya, P; Lee, J L; Bera, J C; Chen, W S; Inserra, C

    2015-09-01

    The stochastic behavior of cavitation can lead to major problems of initiation and maintenance of cavitation during sonication, responsible of poor reproducibility of US-induced bioeffects in the context of sonoporation for instance. To overcome these disadvantages, the injection of ultrasound contrast agents as cavitation nuclei ensures fast initiation and lower acoustic intensities required for cavitation activity. More recently, regulated-cavitation devices based on the real-time modulation of the applied acoustic intensity have shown their potential to maintain a stable cavitation state during an ultrasonic shot, in continuous or pulsed wave conditions. In this paper is investigated the interest, in terms of cavitation activity, of using such regulated-cavitation device or injecting ultrasound contrast agents in the sonicated medium. When using fixed applied acoustic intensity, results showed that introducing ultrasound contrast agents increases reproducibility of cavitation activity (coefficient of variation 62% and 22% without and with UCA, respectively). Moreover, the use of the regulated-cavitation device ensures a given cavitation activity (coefficient of variation less 0.4% in presence of UCAs or not). This highlights the interest of controlling cavitation over time to free cavitation-based application from the use of UCAs. Interestingly, during a one minute sonication, while ultrasound contrast agents progressively disappear, the regulated-cavitation device counterbalance their destruction to sustain a stable inertial cavitation activity. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Chest Ultrasound Integrated Teaching of Respiratory System Physiology to Medical Students: A First Experience

    Science.gov (United States)

    Paganini, M.; Rubini, A.

    2015-01-01

    Ultrasound imaging is a useful diagnostic technique that has spread among several different medical specialties within the last few years. Initially restricted to radiology, cardiology, obstetrics, and gynecology, today it is widely used by many specialists, especially in critical care. New graduate physicians will need to be comfortable with…

  16. A framework for human spine imaging using a freehand 3D ultrasound system

    NARCIS (Netherlands)

    Purnama, Ketut E.; Wilkinson, Michael H.F.; Veldhuizen, Albert G.; van Ooijen, Peter M.A.; Lubbers, Jaap; Burgerhof, Johannes G.M.; Sardjono, Tri A.; Verkerke, Gijsbertus Jacob

    2010-01-01

    The use of 3D ultrasound imaging to follow the progression of scoliosis, i.e., a 3D deformation of the spine, is described. Unlike other current examination modalities, in particular based on X-ray, its non-detrimental effect enables it to be used frequently to follow the progression of scoliosis

  17. The SEP "robot": a valid virtual reality robotic simulator for the Da Vinci Surgical System?

    Science.gov (United States)

    van der Meijden, O A J; Broeders, I A M J; Schijven, M P

    2010-04-01

    The aim of the study was to determine if the concept of face and construct validity may apply to the SurgicalSim Educational Platform (SEP) "robot" simulator. The SEP robot simulator is a virtual reality (VR) simulator aiming to train users on the Da Vinci Surgical System. To determine the SEP's face validity, two questionnaires were constructed. First, a questionnaire was sent to users of the Da Vinci system (reference group) to determine a focused user-group opinion and their recommendations concerning VR-based training applications for robotic surgery. Next, clinical specialists were requested to complete a pre-tested face validity questionnaire after performing a suturing task on the SEP robot simulator. To determine the SEP's construct validity, outcome parameters of the suturing task were compared, for example, relative to participants' endoscopic experience. Correlations between endoscopic experience and outcome parameters of the performed suturing task were tested for significance. On an ordinal five-point, scale the average score for the quality of the simulator software was 3.4; for its hardware, 3.0. Over 80% agreed that it is important to train surgeons and surgical trainees to use the Da Vinci. There was a significant but marginal difference in tool tip trajectory (p = 0.050) and a nonsignificant difference in total procedure time (p = 0.138) in favor of the experienced group. In conclusion, the results of this study reflect a uniform positive opinion using VR training in robotic surgery. Concepts of face and construct validity of the SEP robotic simulator are present; however, these are not strong and need to be improved before implementation of the SEP robotic simulator in its present state for a validated training curriculum to be successful .

  18. The study of surgical image quality evaluation system by subjective quality factor method

    Science.gov (United States)

    Zhang, Jian J.; Xuan, Jason R.; Yang, Xirong; Yu, Honggang; Koullick, Edouard

    2016-03-01

    GreenLightTM procedure is an effective and economical way of treatment of benign prostate hyperplasia (BPH); there are almost a million of patients treated with GreenLightTM worldwide. During the surgical procedure, the surgeon or physician will rely on the monitoring video system to survey and confirm the surgical progress. There are a few obstructions that could greatly affect the image quality of the monitoring video, like laser glare by the tissue and body fluid, air bubbles and debris generated by tissue evaporation, and bleeding, just to name a few. In order to improve the physician's visual experience of a laser surgical procedure, the system performance parameter related to image quality needs to be well defined. However, since image quality is the integrated set of perceptions of the overall degree of excellence of an image, or in other words, image quality is the perceptually weighted combination of significant attributes (contrast, graininess …) of an image when considered in its marketplace or application, there is no standard definition on overall image or video quality especially for the no-reference case (without a standard chart as reference). In this study, Subjective Quality Factor (SQF) and acutance are used for no-reference image quality evaluation. Basic image quality parameters, like sharpness, color accuracy, size of obstruction and transmission of obstruction, are used as subparameter to define the rating scale for image quality evaluation or comparison. Sample image groups were evaluated by human observers according to the rating scale. Surveys of physician groups were also conducted with lab generated sample videos. The study shows that human subjective perception is a trustworthy way of image quality evaluation. More systematic investigation on the relationship between video quality and image quality of each frame will be conducted as a future study.

  19. Implementation of surgical debriefing programs in large health systems: an exploratory qualitative analysis.

    Science.gov (United States)

    Brindle, Mary E; Henrich, Natalie; Foster, Andrew; Marks, Stanley; Rose, Michael; Welsh, Robert; Berry, William

    2018-03-27

    The role of the "debrief" to address issues related to patient safety and systematic flaws in care is frequently overlooked. In our study, we interview surgical leaders who have developed successful strategies of debriefing within a comprehensive program of quality improvement. Semi-structured interviews of four implementation leaders were performed. The observations, beliefs and strategies of surgical leaders are compared and contrasted. Common themes are identified related to program success and failure. Quality and safety researchers performed, coded and categorized the interviews and coordinated the analysis and interpretation of the results. The authors from the four institutions aided in interpretation and framing of the results. The debriefing programs evaluated were part of comprehensive quality improvement projects. Seven high-level themes and 24 subthemes were identified from the interviews. Themes related to leadership included early engagement, visible ongoing commitment and enforcement. Success appeared to depend upon meaningful and early debriefing feedback. The culture of safety that promoted success included a commitment to open and fair communication and continuous improvement. There were many challenges to the success of debriefing programs. The loss of institutional commitment of resources and personnel was the instigating factor behind the collapse of the program at Michigan. Other areas of potential failure included communication issues and loss of early and meaningful feedback. Leaders of four surgical systems with strong debriefing programs report success using debriefing to improve system performance. These findings are consistent with previously published studies. Success requires commitment of resources, and leadership engagement. The greatest gains may be best achieved by programs that provide meaningful debriefing feedback in an atmosphere dedicated to open communication.

  20. The da Vinci telerobotic surgical system: the virtual operative field and telepresence surgery.

    Science.gov (United States)

    Ballantyne, Garth H; Moll, Fred

    2003-12-01

    The United States Department of Defense developed the telepresence surgery concept to meet battlefield demands. The da Vinci telerobotic surgery system evolved from these efforts. In this article, the authors describe the components of the da Vinci system and explain how the surgeon sits at a computer console, views a three-dimensional virtual operative field, and performs the operation by controlling robotic arms that hold the stereoscopic video telescope and surgical instruments that simulate hand motions with seven degrees of freedom. The three-dimensional imaging and handlike motions of the system facilitate advanced minimally invasive thoracic, cardiac, and abdominal procedures. da Vinci has recently released a second generation of telerobots with four arms and will continue to meet the evolving challenges of surgery.

  1. Truth in Reporting: How Data Capture Methods Obfuscate Actual Surgical Site Infection Rates within a Health Care Network System.

    Science.gov (United States)

    Bordeianou, Liliana; Cauley, Christy E; Antonelli, Donna; Bird, Sarah; Rattner, David; Hutter, Matthew; Mahmood, Sadiqa; Schnipper, Deborah; Rubin, Marc; Bleday, Ronald; Kenney, Pardon; Berger, David

    2017-01-01

    Two systems measure surgical site infection rates following colorectal surgeries: the American College of Surgeons National Surgical Quality Improvement Program and the Centers for Disease Control and Prevention National Healthcare Safety Network. The Centers for Medicare & Medicaid Services pay-for-performance initiatives use National Healthcare Safety Network data for hospital comparisons. This study aimed to compare database concordance. This is a multi-institution cohort study of systemwide Colorectal Surgery Collaborative. The National Surgical Quality Improvement Program requires rigorous, standardized data capture techniques; National Healthcare Safety Network allows 5 data capture techniques. Standardized surgical site infection rates were compared between databases. The Cohen κ-coefficient was calculated. This study was conducted at Boston-area hospitals. National Healthcare Safety Network or National Surgical Quality Improvement Program patients undergoing colorectal surgery were included. Standardized surgical site infection rates were the primary outcomes of interest. Thirty-day surgical site infection rates of 3547 (National Surgical Quality Improvement Program) vs 5179 (National Healthcare Safety Network) colorectal procedures (2012-2014). Discrepancies appeared: National Surgical Quality Improvement Program database of hospital 1 (N = 1480 patients) routinely found surgical site infection rates of approximately 10%, routinely deemed rate "exemplary" or "as expected" (100%). National Healthcare Safety Network data from the same hospital and time period (N = 1881) revealed a similar overall surgical site infection rate (10%), but standardized rates were deemed "worse than national average" 80% of the time. Overall, hospitals using less rigorous capture methods had improved surgical site infection rates for National Healthcare Safety Network compared with standardized National Surgical Quality Improvement Program reports. The correlation coefficient

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... be able to give a clearer picture of soft tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may be repeated as often as is necessary if medically indicated. Ultrasound provides real-time imaging, making it a good tool for guiding ...

  3. Prostate Ultrasound

    Science.gov (United States)

    ... be able to give a clearer picture of soft tissues that do not show up well on x-ray images. Ultrasound causes no health problems and may be repeated as often as is necessary if medically indicated. Ultrasound provides real-time imaging, making it a good tool for guiding ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging of the pelvis uses sound waves to ...

  5. Interventional ultrasound

    International Nuclear Information System (INIS)

    VanSonnenberg, E.

    1987-01-01

    This book contains 12 chapters and several case studies. Some of the chapter titles are: The Interplay of Ultrasound and Computed Tomography in the Planning and Execution of Interventional Procedures: Ulltrasound Guided Biopsy; Interventioal Genitourinary Sonography; Diagnosis and Treatment of Pericardial Effusion Using Ultrasonic Guidance; and New Ultrasound-Guided Interventional Procedures--Cholecystostomy, Pancreatography, Gastrostomy

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Pelvis Ultrasound imaging ...

  7. Prostate Ultrasound

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Ultrasound - Prostate Ultrasound of ...

  8. Ultrasound stethoscopy

    NARCIS (Netherlands)

    E.C. Vourvouri (Eleni)

    2002-01-01

    textabstractIn this thesis we repmi the many evaluation studies with the hand-held ultrasound device in the assessment of different cardiac pathologies and in different clinical settings. The reason for using the tetm "ultrasound stethoscopy" is that these devices are augmenting our

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not use any ionizing radiation. Ultrasound scanning gives a clear picture of soft tissues that do not show up well on ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the best way to see if treatment is working or if a finding is stable or changed over time. top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use and less expensive than other imaging methods. Ultrasound imaging uses ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the patient. Because ultrasound images are captured in real-time, they can show the structure and movement of ... blood test result. difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide ...

  12. Clinical Experience of the Treatment of Solitary Pulmonary Nodules with Da Vinci Surgical System

    Directory of Open Access Journals (Sweden)

    Xiangdong TONG

    2014-07-01

    Full Text Available Background and objective A solitary pulmonary nodule (SPN is defined as a round intraparenchimal lung lesion less than 3 cm in size, not associated with atelectasis or adenopathy. The aim of this study is to learn clinical experience of the treatment of SPN with Da Vinci Surgical System. Methods A total of 9 patients with solitary pulmonary nodules (SPN less than 3 cm in diameter was treated with Da Vinci Surgical System (Intuitive Surgical, California in thoracic surgery department from General Hospital of Shenyang Militrary Region from November 2011 to March 2014. This group of patients included 3 males and 6 females, and the mean age was 51±9.9 yr (range: 41-74 yr. Most of the patients were no obvious clinical symptoms (7 cases were found by physical examination, others were with cough and expectoration. Their median medical history was 12 mo (range: 4 d-3 yr. All the lesions of patients were peripheral pulmonary nodules and the mean diameter of those was (1.4±0.6 cm(range: 0.8-2.8 cm. Wedge-shaped resection or lobectomy was performed depending on the result of rapid pathology and systemic lymph node dissection was done for malignant leision. We used general anesthesis with double lumens trachea cannula. We set the patients in lateral decubitus position with jackknife. The patient cart enter from top of the patient. The position of trocars would be set according to the position of lesion. A 12 mm incision was positioned at the 8th intercostal space in the posterior axillary line as vision port, and two 8 mm incisions were positioned at the 5th intercostal space between the anterior axillary line and midclavicular line, and the 8th infrascapular line as robotic instrument ports about 10 cm apart from the vision port. One additional auxiliary small incision for instrument without retracting ribs was set at the 7th intercostal space in the middle axillary line. Results There were 4 benign leisions and 5 malignancies identified. Wedge

  13. The vacuum-assisted closure (V.A.C®) system for surgical site infection with involved vascular grafts.

    Science.gov (United States)

    Saziye, Karaca; Afksendiyos, Kalangos

    2015-04-01

    In vascular surgery, surgical site infection is the most common postoperative morbidity, occurring in 5-10% of vascular patients. The optimal management of surgical site infection with involved lower limb vascular grafts remains controversial. We present our 6-year results of using the V.A.C.® system in surgical site infection with involved vascular grafts. A retrospective 6-year review of patient who underwent a VAC® therapy for postoperative surgical site infection in lower limb with involved vascular grafts in our department between January 2006 and December 2011. V.A.C therapy was used in 40 patients. All patients underwent surgical wound revision with VAC® therapy and antibiotics. The mean time of use of the V.A.C. system was 14.2 days. After mean of 12 days in 34 of 40 patients, in whom the use of VAC® therapy resulted in delayed primary closure or healing by secondary intention. The mean postoperative follow-up time was 61.67 months, during which 3 patients died. We showed that the V.A.C.® system is valuable for managing specifically surgical site infection with involved vascular grafts. Using the V.A.C.® system, reoperation rates are reduced; 85% of patients avoided graft replacement. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  14. Abortion - surgical

    Science.gov (United States)

    Suction curettage; Surgical abortion; Elective abortion - surgical; Therapeutic abortion - surgical ... Surgical abortion involves dilating the opening to the uterus (cervix) and placing a small suction tube into the uterus. ...

  15. Computer versus paper system for recognition and management of sepsis in surgical intensive care.

    Science.gov (United States)

    Croft, Chasen A; Moore, Frederick A; Efron, Philip A; Marker, Peggy S; Gabrielli, Andrea; Westhoff, Lynn S; Lottenberg, Lawrence; Jordan, Janeen; Klink, Victoria; Sailors, R Matthew; McKinley, Bruce A

    2014-02-01

    A system to provide surveillance, diagnosis, and protocolized management of surgical intensive care unit (SICU) sepsis was undertaken as a performance improvement project. A system for sepsis management was implemented for SICU patients using paper followed by a computerized system. The hypothesis was that the computerized system would be associated with improved process and outcomes. A system was designed to provide early recognition and guide patient-specific management of sepsis including (1) modified early warning signs-sepsis recognition score (MEWS-SRS; summative point score of ranges of vital signs, mental status, white blood cell count; after every 4 hours) by bedside nurse; (2) suspected site assessment (vascular access, lung, abdomen, urinary tract, soft tissue, other) at bedside by physician or extender; (3) sepsis management protocol (replicable, point-of-care decisions) at bedside by nurse, physician, and extender. The system was implemented first using paper and then a computerized system. Sepsis severity was defined using standard criteria. In January to May 2012, a paper system was used to manage 77 consecutive sepsis encounters (3.9 ± 0.5 cases per week) in 65 patients (77% male; age, 53 ± 2 years). In June to December 2012, a computerized system was used to manage 132 consecutive sepsis encounters (4.4 ± 0.4 cases per week) in 119 patients (63% male; age, 58 ± 2 years). MEWS-SRS elicited 683 site assessments, and 201 had sepsis diagnosis and protocol management. The predominant site of infection was abdomen (paper, 58%; computer, 53%). Recognition of early sepsis tended to occur more using the computerized system (paper, 23%; computer, 35%). Hospital mortality rate for surgical ICU sepsis (paper, 20%; computer, 14%) was less with the computerized system. A computerized sepsis management system improves care process and outcome. Early sepsis is recognized and managed with greater frequency compared with severe sepsis or septic shock. The system

  16. The Settings, Pros and Cons of the New Surgical Robot da Vinci Xi System for Transoral Robotic Surgery (TORS): A Comparison With the Popular da Vinci Si System.

    Science.gov (United States)

    Kim, Da Hee; Kim, Hwan; Kwak, Sanghyun; Baek, Kwangha; Na, Gina; Kim, Ji Hoon; Kim, Se Heon

    2016-10-01

    The da Vinci system (da Vinci Surgical System; Intuitive Surgical Inc.) has rapidly developed in several years from the S system to the Si system and now the Xi System. To investigate the surgical feasibility and to provide workflow guidance for the newly released system, we used the new da Vinci Xi system for transoral robotic surgery (TORS) on a cadaveric specimen. Bilateral supraglottic partial laryngectomy, hypopharyngectomy, lateral oropharyngectomy, and base of the tongue resection were serially performed in search of the optimal procedures with the new system. The new surgical robotic system has been upgraded in all respects. The telescope and camera were incorporated into one system, with a digital end-mounted camera. Overhead boom rotation allows multiquadrant access without axis limitation, the arms are now thinner and longer with grabbing movements for easy adjustments. The patient clearance button dramatically reduces external collisions. The new surgical robotic system has been optimized for improved anatomic access, with better-equipped appurtenances. This cadaveric study of TORS offers guidance on the best protocol for surgical workflow with the new Xi system leading to improvements in the functional results of TORS.

  17. Coding and Billing in Surgical Education: A Systems-Based Practice Education Program.

    Science.gov (United States)

    Ghaderi, Kimeya F; Schmidt, Scott T; Drolet, Brian C

    Despite increased emphasis on systems-based practice through the Accreditation Council for Graduate Medical Education core competencies, few studies have examined what surgical residents know about coding and billing. We sought to create and measure the effectiveness of a multifaceted approach to improving resident knowledge and performance of documenting and coding outpatient encounters. We identified knowledge gaps and barriers to documentation and coding in the outpatient setting. We implemented a series of educational and workflow interventions with a group of 12 residents in a surgical clinic at a tertiary care center. To measure the effect of this program, we compared billing codes for 1 year before intervention (FY2012) to prospectively collected data from the postintervention period (FY2013). All related documentation and coding were verified by study-blinded auditors. Interventions took place at the outpatient surgical clinic at Rhode Island Hospital, a tertiary-care center. A cohort of 12 plastic surgery residents ranging from postgraduate year 2 through postgraduate year 6 participated in the interventional sequence. A total of 1285 patient encounters in the preintervention group were compared with 1170 encounters in the postintervention group. Using evaluation and management codes (E&M) as a measure of documentation and coding, we demonstrated a significant and durable increase in billing with supporting clinical documentation after the intervention. For established patient visits, the monthly average E&M code level increased from 2.14 to 3.05 (p coding and billing of outpatient clinic encounters. Using externally audited coding data, we demonstrate significantly increased rates of higher complexity E&M coding in a stable patient population based on improved documentation and billing awareness by the residents. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  18. Surgical treatment of female stress urinary incontinence with the Gynecare TVT Secur™ System – preliminary report

    Directory of Open Access Journals (Sweden)

    Włodzimierz Baranowski

    2010-02-01

    Full Text Available Introduction: Sling procedures were first introduced over 100 years ago in the treatment of stress urinaryincontinence. Since then they have evolved to become less invasive and safer. The sling procedure using theGynecare TVT Secur™ system is a new therapeutic option for women with stress urinary incontinence.Objectives: To evaluate the efficacy and safety of Gynecare TVT Secur™ in the surgical treatment of stressurinary incontinence in women. Material and methods: The study comprised consecutive female patients admitted to the Department ofGynaecology and Gynaecological Oncology of the Military Institute of Health Services in Warsaw, Poland, whohad been qualified for surgical treatment of stress urinary incontinence on the basis of physical signs and symptomsand the findings of a urodynamic study. The procedure was performed using the Gynecare TVT Secur™system with tapes introduced in an H- or U-shape mode. Results: Between October 2006 and September 2009, 77 sling procedures using the Gynecare TVT Secur™system were performed in women with stress urinary incontinence. Their mean age was 55.1 (30-76 years, meanBMI 28.5 (20.2-43.8 kg/m2. Sixty-nine implants were positioned in H-shape mode, 8 in U-shape mode. Fortyninewomen (63.6% were menopausal, 14 (18.2% previously had three or more natural deliveries, 13 (16.8%had a history of gynaecological surgeries. Thirty-one procedures were performed under general anaesthesia and46 under local anaesthesia. The mean duration of the surgery was 9 (4-42 minutes. It was possible to dischargefifty-seven (74% women on the day of the surgery. Urine retention was observed only in 1 (1.7% woman. Noother complications were recorded. Conclusions: The surgical treatment of urinary incontinence with sling procedures using the Gynecare TVTSecur™ system shows good immediate efficacy and safety. Considering this as well as the short duration ofthe procedure and its good tolerability under local anaesthesia, use

  19. Microsurgical robotic system for the deep surgical field: development of a prototype and feasibility studies in animal and cadaveric models.

    Science.gov (United States)

    Morita, Akio; Sora, Shigeo; Mitsuishi, Mamoru; Warisawa, Shinichi; Suruman, Katopo; Asai, Daisuke; Arata, Junpei; Baba, Shoichi; Takahashi, Hidechika; Mochizuki, Ryo; Kirino, Takaaki

    2005-08-01

    To enhance the surgeon's dexterity and maneuverability in the deep surgical field, the authors developed a master-slave microsurgical robotic system. This concept and the results of preliminary experiments are reported in this paper. The system has a master control unit, which conveys motion commands in six degrees of freedom (X, Y, and Z directions; rotation; tip flexion; and grasping) to two arms. The slave manipulator has a hanging base with an additional six degrees of freedom; it holds a motorized operating unit with two manipulators (5 mm in diameter, 18 cm in length). The accuracy of the prototype in both shallow and deep surgical fields was compared with routine freehand microsurgery. Closure of a partial arteriotomy and complete end-to-end anastomosis of the carotid artery (CA) in the deep operative field were performed in 20 Wistar rats. Three routine surgical procedures were also performed in cadavers. The accuracy of pointing with the nondominant hand in the deep surgical field was significantly improved through the use of robotics. The authors successfully closed the partial arteriotomy and completely anastomosed the rat CAs in the deep surgical field. The time needed for stitching was significantly shortened over the course of the first 10 rat experiments. The robotic instruments also moved satisfactorily in cadavers, but the manipulators still need to be smaller to fit into the narrow intracranial space. Computer-controlled surgical manipulation will be an important tool for neurosurgery, and preliminary experiments involving this robotic system demonstrate its promising maneuverability.

  20. Comparison of shear wave velocity measurements assessed with two different ultrasound systems in an ex-vivo tendon strain phantom.

    Science.gov (United States)

    Rosskopf, Andrea B; Bachmann, Elias; Snedeker, Jess G; Pfirrmann, Christian W A; Buck, Florian M

    2016-11-01

    The purpose of this study is to compare the reliability of SW velocity measurements of two different ultrasound systems and their correlation with the tangent traction modulus in a non-static tendon strain model. A bovine tendon was fixed in a custom-made stretching device. Force was applied increasing from 0 up to 18 Newton. During each strain state the tangent traction modulus was determined by the stretcher device, and SW velocity (m/s) measurements using a Siemens S3000 and a Supersonic Aixplorer US machine were done for shear modulus (kPa) calculation. A strong significant positive correlation was found between SW velocity assessed by the two ultrasound systems and the tangent traction modulus (r = 0.827-0.954, p Aixplorer 0.25 ± 0.3 m/s (p = 0.034). Mean difference of SW velocity between the two US-systems was 0.37 ± 0.3 m/s (p = 0.012). In conclusion, SW velocities are highly dependent on mechanical forces in the tendon tissue, but for controlled mechanical loads appear to yield reproducible and comparable measurements using different US systems.

  1. Line fiducial material and thickness considerations for ultrasound calibration

    Science.gov (United States)

    Ameri, Golafsoun; McLeod, A. J.; Baxter, John S. H.; Chen, Elvis C. S.; Peters, Terry M.

    2015-03-01

    Ultrasound calibration is a necessary procedure in many image-guided interventions, relating the position of tools and anatomical structures in the ultrasound image to a common coordinate system. This is a necessary component of augmented reality environments in image-guided interventions as it allows for a 3D visualization where other surgical tools outside the imaging plane can be found. Accuracy of ultrasound calibration fundamentally affects the total accuracy of this interventional guidance system. Many ultrasound calibration procedures have been proposed based on a variety of phantom materials and geometries. These differences lead to differences in representation of the phantom on the ultrasound image which subsequently affect the ability to accurately and automatically segment the phantom. For example, taut wires are commonly used as line fiducials in ultrasound calibration. However, at large depths or oblique angles, the fiducials appear blurred and smeared in ultrasound images making it hard to localize their cross-section with the ultrasound image plane. Intuitively, larger diameter phantoms with lower echogenicity are more accurately segmented in ultrasound images in comparison to highly reflective thin phantoms. In this work, an evaluation of a variety of calibration phantoms with different geometrical and material properties for the phantomless calibration procedure was performed. The phantoms used in this study include braided wire, plastic straws, and polyvinyl alcohol cryogel tubes with different diameters. Conventional B-mode and synthetic aperture images of the phantoms at different positions were obtained. The phantoms were automatically segmented from the ultrasound images using an ellipse fitting algorithm, the centroid of which is subsequently used as a fiducial for calibration. Calibration accuracy was evaluated for these procedures based on the leave-one-out target registration error. It was shown that larger diameter phantoms with lower

  2. Robotics and telecommunication systems to provide better access to ultrasound expertise in the OR.

    Science.gov (United States)

    Angelini, L; Papaspyropoulos, V

    2000-01-01

    Surgery has begun to evolve as a result of the intense use of technological innovations. The result of this is better services for patients and enormous opportunities for the producers of biomedical instruments. The surgeon and the technologist are fast becoming allies in applying the latest developments of robotics, image treatment, simulation, sensors and telecommunications to surgery, in particular to the emerging field of minimally-invasive surgery. Ultrasonography is at present utilised both for diagnostic and therapeutic purposes in various fields. Intraoperative US examination can be of primary importance, especially when dealing with space-occupying lesions. The widening use of minimally-invasive surgery has furthered the development of US for use during this type of surgery. The success of a US examination requires not only a correct execution of the procedure, but also a correct interpretation of the images. We describe two projects that combine robotics and telecommunication systems to provide better access to US expertise in the operating room. The Midstep project has as its object the realisation of two robotic arms, one for the distant control of the US probe during laparoscopic surgery and the second to perform tele-interventional US. The second project, part of the Strategic CNR Project-'Robotics in Surgery', involves the realisation of a common platform for tracking and targeting surgical instruments in video-assisted surgery.

  3. Surgical management of gastroesophageal reflux disease in patients with systemic sclerosis.

    Science.gov (United States)

    Yan, Jingliang; Strong, Andrew T; Sharma, Gautam; Gabbard, Scott; Thota, Prashanti; Rodriguez, John; Kroh, Matthew

    2018-02-12

    Systemic sclerosis (scleroderma) is frequently associated with both gastroesophageal reflux disease (GERD) and simultaneous esophageal dysmotility. Anti-reflux procedures in this patient population must account for the existing physiology of each patient and likely disease progression. We aim to compare perioperative and intermediate outcomes of fundoplication versus gastric bypass for the treatment of GERD. After IRB approval, patients with systemic sclerosis undergoing fundoplication or gastric bypass for the treatment of GERD from 2004 to 2016 were identified. Demographics, perioperative data, immediate complications, and symptom improvement were retrieved and analyzed. Fourteen patients with systemic sclerosis underwent surgical treatment of GERD during the defined study period. Average body mass index was 26 kg/m 2 . Seven fundoplications (2 Nissens, 4 Toupets, and 1 Dor) and 7 Roux-en-Y gastric bypasses (RYGB) were performed. No 30-day mortality was observed in either group. Median follow-up was 97 months for the fundoplication group (range 28-204 months), and 19 months for the RYGB group (range 1-164 months). Preoperatively, dysphagia, heartburn, and regurgitation were present in 71% (n = 10), 86% (n = 12), and 64% (n = 9) of patients, respectively. Eleven patients had pH study prior to surgical intervention, and 91% of them had abnormal acid exposure. Esophagitis was evident in 85% (n = 11) of patients during preoperative upper endoscopy, and two patients had Barrett's esophagus. Impaired esophageal motility was present in all RYGB patients and 71% of fundoplication patients. Of the patients who had assessment of their GERD symptoms at follow-up, all five patients in the RYGB group and only 3 (50%) patients in the fundoplication group reported symptom improvement or resolution. Laparoscopic RYGB as an anti-reflux procedure is safe and may provide an alternative to fundoplication in the treatment of GERD for systemic sclerosis patients

  4. Drainage Systems Effect on Surgical Site Infection in Children with Perforated Appendicitis

    Directory of Open Access Journals (Sweden)

    Seref Kilic

    2016-09-01

    Full Text Available Aim: Effect of replacing open drainage system to closed drainage system on surgical site infection (SSI in children operated for perforated appendicitis was evaluated. Material and Method: Hospital files and computer records of perforated appendicitis cases operated in 2004-2010 were evaluated retrospectively. Open drainage systems were used for 70 in cases (group I and closed systems were used in the others (group II. Results: Eleven of SSI cases had superficial infection and 3 had the organ/space infection. SSI rate was 15.7% for group I and 7.5% for the group II. The antibiotic treatment length was 7.5 ± 3.4 days for group I and 6.4 ± 2.2 days for group II and the difference between groups was not statistically significant. Hospitalization length for group I was 8.2 ± 3.1 days and 6.8 ± 1.9 days for group II and the difference was statistically significant. Discussion: SSI is an important problem increasing morbidity and treatment costs through increasing hospitalization and antibiotic treatment length. Open drainage system used in operation in patients with perforated appendicitis leads an increased frequency of SSI when compared to the closed drainage system. Thus, closed drainage systems should be preferred in when drainage is necessary in operations for perforated appendicitis in children.

  5. A Study of Laser-generated Ultrasound for Evaluation of Thickness Reduction in Piping System

    International Nuclear Information System (INIS)

    Seo, Kyung Chul; Choi, Sang Woo; Lee, Jun Hyun; Kang, Seung Hyun

    2005-01-01

    In carbon steel pipes of nuclear power plants, local wall thinning may result from erosion-corrosion or FAC(Flow Accelerated Corrosion) damage. Local wall thinning is one of the major causes for the structural fracture of these pipes. Therefore, assessment of local wall thinning due to corrosion is an important issue in nondestructive evaluation for the integrity of nuclear power plants. In this study, laser-generated ultrasound technique was employed to evaluate local wall thinning due to corrosion. Guided waves were generated in the thermoelastic regime using a Q-switched pulsed Nd:YAG laser with an linear array slit. Time-frequency analysis of ultrasonic waveforms using wavelet transform and FRT(Fast Fourier Transform) allowed the identification of generated guided wave modes by comparison with the theoretical dispersion curves. This study shows some experimental results about optimization of generating laser ultrasound using various linear array slits.

  6. [Applicability of the da Vinci robotic system in the skull base surgical approach. Preclinical investigation].

    Science.gov (United States)

    Fernandez-Nogueras Jimenez, Francisco J; Segura Fernandez-Nogueras, Miguel; Jouma Katati, Majed; Arraez Sanchez, Miguel Ángel; Roda Murillo, Olga; Sánchez Montesinos, Indalecio

    2015-01-01

    The role of robotic surgery is well established in various specialties such as urology and general surgery, but not in others such as neurosurgery and otolaryngology. In the case of surgery of the skull base, it has just emerged from an experimental phase. To investigate possible applications of the da Vinci surgical robot in transoral skull base surgery, comparing it with the authors' experience using conventional endoscopic transnasal surgery in the same region. A transoral transpalatal approach to the nasopharynx and medial skull base was performed on 4 cryopreserved cadaver heads. We used the da Vinci robot, a 30° standard endoscope 12mm thick, dual camera and dual illumination, Maryland forceps on the left terminal and curved scissors on the right, both 8mm thick. Bone drilling was performed manually. For the anatomical study of this region, we used 0.5cm axial slices from a plastinated cadaver head. Various skull base structures at different depths were reached with relative ease with the robot terminals Transoral robotic surgery with the da Vinci system provides potential advantages over conventional endoscopic transnasal surgery in the surgical approach to this region. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  7. Portable Ultrasound Imaging

    DEFF Research Database (Denmark)

    di Ianni, Tommaso

    This PhD project investigates hardware strategies and imaging methods for hand-held ultrasound systems. The overall idea is to use a wireless ultrasound probe linked to general-purpose mobile devices for the processing and visualization. The approach has the potential to reduce the upfront costs...... beamforming strategies are simulated from a system-level perspective. The quality of the B-mode image is evaluated and the minimum specifications are derived for the design of a portable probe with integrated electronics in-handle. The system is based on a synthetic aperture sequential beamforming approach...... that allows to significantly reduce the data rate between the probe and processing unit. The second part investigates the feasibility of vector flow imaging in a hand-held ultrasound system. Vector flow imaging overcomes the limitations of conventional imaging methods in terms of flow angle compensation...

  8. Research of Ultrasound-Mediated Transdermal Drug Delivery System Using Cymbal-Type Piezoelectric Composite Transducer

    Science.gov (United States)

    Huan, Huiting; Gao, Chunming; Liu, Lixian; Sun, Qiming; Zhao, Binxing; Yan, Laijun

    2015-06-01

    Transdermal drug delivery (TDD) implemented by especially low-frequency ultrasound is generally known as sonophoresis or phonophoresis which has drawn considerable wide attention. However, TDD has not yet achieved its full potential as an alternative to conventional drug delivery methods due to its bulky instruments. In this paper, a cymbal-type piezoelectric composite transducer (CPCT) which has advantages over a traditional ultrasound generator in weight, flexibility, and power consumption, is used as a substitute ultrasonicator to realize TDD. First, theoretical research on a CPCT based on the finite element analysis was carried out according to which a series of applicable CPCTs with bandwidths of 20 kHz to 100 kHz were elaborated. Second, a TDD experimental setup was built with previously fabricated CPCTs aimed at the administration of glucose. Finally, the TDD performance of glucose molecule transport in porcine skin was measured in vitro by quantifying the concentration of glucose, and the time variation curves were subsequently obtained. During the experiment, the driving wave form, frequency, and power consumption of the transducers were selected as the main elements which determined the efficacy of glucose delivery. The results indicate that the effectiveness of the CPCT-based delivery is constrained more by the frequency and intensity of ultrasound rather than the driving waveform. The light-weight, flexibility, and low-power consumption of a CPCT can potentially achieve effective TDD.

  9. Optical detection of ultrasound using an apertureless near-field scanning optical microscopy system

    Science.gov (United States)

    Ahn, Phillip; Zhang, Zhen; Sun, Cheng; Balogun, Oluwaseyi

    2013-01-01

    Laser ultrasonics techniques are power approaches for non-contact generation and detection of high frequency ultrasound on a local scale. In these techniques, optical diffraction limits the spatial information that can be accessed from a measurement. In order to improve the lateral spatial resolution, we incorporate an apertureless near-field scanning optical microscope (aNSOM) into laser ultrasonics setup for local detection of laser generated ultrasound. The aNSOM technique relies on the measurement of a weak backscattered near-field light intensity resulting from the oblique illumination of a nanoscale probe-tip positioned close to a sample surface. We enhance the optical near-field intensity by coupling light to surface plasmon polaritons (SPPs) on the shaft of an atomic force microscopy (AFM) cantilever. The SPPs propagate down the AFM shaft, localize at the tip apex, and are backscattered to the far-field when the separation distance between the probe tip and the sample surface is comparable to the probe-tip radius. The backscattered near-field intensity is dynamically modulated when an ultrasonic wave arrives at the sample surface leading to a transient change in the tip-sample separation distance. We present experimental results detailing measurement of broadband and narrowband laser generated ultrasound in solids with frequencies reaching up to 180 MHz range.

  10. Experimental and clinical trial of measuring urinary velocity with the pitot tube and a transrectal ultrasound guided video urodynamic system.

    Science.gov (United States)

    Tsujimoto, Yukio; Nose, Yorihito; Ohba, Kenkichi

    2003-01-01

    The pitot tube is a common device to measure flow velocity. If the pitot tube is used as an urodynamic catheter, urinary velocity and urethral pressure may be measured simultaneously. However, to our knowledge, urodynamic studies with the pitot tube have not been reported. We experimentally and clinically evaluated the feasibility of the pitot tube to measure urinary velocity with a transrectal ultrasound guided video urodynamic system. We carried out a basal experiment measuring flow velocity in model urethras of 4.5-8.0 mm in inner diameter with a 12-Fr pitot tube. In a clinical trial, 79 patients underwent transrectal ultrasound guided video urodynamic studies with the 12-Fr pitot tube. Urinary velocity was calculated from dynamic pressure (Pd) with the pitot tube formula and the correcting equation according to the results of the basal experiment. Velocity measured by the pitot tube was proportional to the average velocity in model urethras and the coefficients were determined by diameters of model urethras. We obtained a formula to calculate urinary velocity from the basal experiment. The urinary velocity could be obtained in 32 of 79 patients. Qmax was 8.1 +/- 4.3 mL/s (mean +/- SD; range, 18.4-1.3 mL/s), urethral diameter was 7.3 +/- 3.0 mm (mean +/- SD; range, 18.7-4.3 mm) and urinary velocity was 69.4 +/- 43.6 (mean +/- SD; range, 181.3-0 cm/s) at maximum flow rate. The correlation coefficient of Qmax measured by a flowmeter versus Qdv flow rate calculated with urethral diameter and velocity was 0.41 without significant difference. The use of the pitot tube as an urodynamic catheter to a transrectal ultrasound-guided video urodynamic system can measure urethral pressure, diameter and urinary velocity simultaneously. However, a thinner pitot tube and further clinical trials are needed to obtain more accurate results.

  11. Surgical outcomes of robot-assisted rectal cancer surgery using the da Vinci Surgical System: a multi-center pilot Phase II study.

    Science.gov (United States)

    Tsukamoto, Shunsuke; Nishizawa, Yuji; Ochiai, Hiroki; Tsukada, Yuichiro; Sasaki, Takeshi; Shida, Dai; Ito, Masaaki; Kanemitsu, Yukihide

    2017-12-01

    We conducted a multi-center pilot Phase II study to examine the safety of robotic rectal cancer surgery performed using the da Vinci Surgical System during the introduction period of robotic rectal surgery at two institutes based on surgical outcomes. This study was conducted with a prospective, multi-center, single-arm, open-label design to assess the safety and feasibility of robotic surgery for rectal cancer (da Vinci Surgical System). The primary endpoint was the rate of adverse events during and after robotic surgery. The secondary endpoint was the completion rate of robotic surgery. Between April 2014 and July 2016, 50 patients were enrolled in this study. Of these, 10 (20%) had rectosigmoid cancer, 17 (34%) had upper rectal cancer, and 23 (46%) had lower rectal cancer; six underwent high anterior resection, 32 underwent low anterior resection, 11 underwent intersphincteric resection, and one underwent abdominoperineal resection. Pathological stages were Stage 0 in 1 patient, Stage I in 28 patients, Stage II in 7 patients and Stage III in 14 patients. Pathologically complete resection was achieved in all patients. There was no intraoperative organ damage or postoperative mortality. Eight (16%) patients developed complications of all grades, of which 2 (4%) were Grade 3 or higher, including anastomotic leakage (2%) and conversion to open surgery (2%). The present study demonstrates the feasibility and safety of robotic rectal cancer surgery, as reflected by low morbidity and low conversion rates, during the introduction period. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  12. Development of estimation system of knee extension strength using image features in ultrasound images of rectus femoris

    Science.gov (United States)

    Murakami, Hiroki; Watanabe, Tsuneo; Fukuoka, Daisuke; Terabayashi, Nobuo; Hara, Takeshi; Muramatsu, Chisako; Fujita, Hiroshi

    2016-04-01

    The word "Locomotive syndrome" has been proposed to describe the state of requiring care by musculoskeletal disorders and its high-risk condition. Reduction of the knee extension strength is cited as one of the risk factors, and the accurate measurement of the strength is needed for the evaluation. The measurement of knee extension strength using a dynamometer is one of the most direct and quantitative methods. This study aims to develop a system for measuring the knee extension strength using the ultrasound images of the rectus femoris muscles obtained with non-invasive ultrasonic diagnostic equipment. First, we extract the muscle area from the ultrasound images and determine the image features, such as the thickness of the muscle. We combine these features and physical features, such as the patient's height, and build a regression model of the knee extension strength from training data. We have developed a system for estimating the knee extension strength by applying the regression model to the features obtained from test data. Using the test data of 168 cases, correlation coefficient value between the measured values and estimated values was 0.82. This result suggests that this system can estimate knee extension strength with high accuracy.

  13. Surgical Management of Renal Cell Carcinoma Extending Into Venous System: A 20-Year Experience.

    Science.gov (United States)

    Xiao, X; Zhang, L; Chen, X; Cui, L; Zhu, H; Pang, D; Yang, Y; Wang, Q; Wang, M; Gao, C

    2017-11-01

    The purpose of this study is to report our 20-year experience with the surgical management of renal cell carcinoma extending into the inferior vena cava using a novel classification system. We retrospectively reviewed the data of 103 patients (69 males, 34 females, mean age: 52.9 ± 12.6 years) with renal cell carcinoma involving the venous system treated between 1993 and 2014. The inferior vena cava tumor thrombus was classified into five levels: 0 (renal vein, n = 12), 1 (infrahepatic, n = 33), 2a (low retrohepatic, n = 26), 2b (high retrohepatic, n = 19), and 3 (supradiaphragmatic, n = 13). Clinical data were summarized, and overall survival, cancer-specific survival, and disease-free survival were examined by Cox regression analysis. All patients underwent radical surgery. Complete resections of the renal tumor and thrombus were achieved in 101 patients (98.1%). Two intraoperative and one postoperative in-hospital deaths (2.9%) occurred. In total, 19 patients (18.8%) had a total of 29 postoperative complications. Mean follow-up time was 46 months (range, 1-239 months). The 5- and 10-year overall survival rates were 62.9% and 56.0%, respectively. Metastasis, rather than thrombus level, was a significant risk factor associated with overall survival (hazard ratio = 4.89, 95% confidence interval: 2.24-10.67, p system can be used to select the optimal surgical approach and method for patients with renal cell carcinoma and venous thrombus. Its use is associated with prolonged survival and relatively few complications. Metastasis is an independent risk factor of overall survival.

  14. Development of a 3D ultrasound system to investigate post-hemorrhagic hydrocephalus in pre-term neonates

    Science.gov (United States)

    Kishimoto, J.; Lee, D.; St. Lawrence, K.; Romano, W.; Fenster, A.; de Ribaupierre, S.

    2013-03-01

    Clinical intracranial ultrasound (US) is performed as a standard of care on neonates at risk of intraventricular hemorrhaging (IVH) and is also used after a diagnosis to monitor for potential ventricular dilation. However, it is difficult to estimate the volume of ventricles with 2D US due to their irregular shape. We developed a 3D US system to be used as an adjunct to a clinical system to investigate volumetric changes in the ventricles of neonates with IVH. Our system has been found have an error of within 1% of actual distance measurements in all three directions and volume measurements of manually segmented volumes from phantoms were not statistically significantly different from the actual values (p>0.3). Interobserver volume measurements of the lateral ventricles in a patient with grade III IVH found no significant differences between measurements. There is the potential to use this system in IVH patients to monitor the progression of ventriculomegaly over time.

  15. Surgical scheduling categorization system (SSCS): A novel classification system to improve coordination and scheduling of operative cases in a tertiary pediatric medical system.

    Science.gov (United States)

    Gantwerker, Eric A; Bannos, Cassandra; Cunningham, Michael J; Rahbar, Reza

    2017-01-01

    To describe a surgical categorization system to create a universal nomenclature, delineating patient complexity as a first step toward developing a true risk stratification system. Retrospective database review of all otolaryngology surgical procedures performed in a tertiary pediatric hospital system over one academic year (July 2012-June 2013). All otolaryngology surgical procedures were reviewed, encompassing 8478 procedures on 5711 patients. The attending otolaryngologist assigned surgical scheduling category (SSCS) at the time of case booking based on an institution specific guidelines. The guidelines are as follow: Category I was assigned to American Society of Anesthesiologists physical status classification (ASA) I/II patients, designating them appropriate for institution's suburban ambulatory surgery centers; Category II was ASA I/II patients with social or transportation issues; Category III was ASA I/II patients who required case coordination with other medical or surgical departments; Category IV was reserved for patients of any ASA class whom the surgeon designated to be of a higher complexity. 8478 total procedures analyzed with 7198 having complete records. 48% were Category I, 13.6% were Category II, 1.9% were Category III and 36.5% were Category IV. The ASA were 34.7% ASA I, 50% ASA II, 13.39% ASA III, and 1.9% ASA IV. Although the largest proportion of patients were ASA II (50%), 39.6% of all ASA II were Category IV. Category IV was split into 54.2% ASA II and 34% ASA III and shows that peri-operative surgical concerns were not encompassed by the ASA system. This surgical categorization system streamlines surgical scheduling in a tertiary pediatric hospital system, particularly with respect to the designation of cases as ambulatory surgery center or main operating room appropriate. The case mix complexity is also readily apparent, enhancing recognition of the coordination and attention required for the perioperative management of high complexity

  16. Surgical anatomy of the hypoglossal nerve: A new classification system for selective upper airway stimulation.

    Science.gov (United States)

    Heiser, Clemens; Knopf, Andreas; Hofauer, Benedikt

    2017-12-01

    Selective upper airway stimulation (UAS) has shown effectiveness in treating patients with obstructive sleep apnea (OSA). The terminating branches of the hypoglossal nerve show a wide complexity, requiring careful discernment of a functional breakpoint between branches for inclusion and exclusion from the stimulation cuff electrode. The purpose of this study was to describe and categorize the topographic phenotypes of these branches. Thirty patients who received an implant with selective UAS from July 2015 to June 2016 were included. All implantations were recorded using a microscope and resultant tongue motions were captured perioperatively for comparison. Eight different variations of the branches were encountered and described, both in a tabular numeric fashion and in pictorial schema. The examinations showed the complex phenotypic surgical anatomy of the hypoglossal nerve. A schematic classification system has been developed to help surgeons identify the optimal location for cuff placement in UAS. © 2017 Wiley Periodicals, Inc.

  17. Fetal Ultrasound

    Science.gov (United States)

    ... isn't recommended simply to determine a baby's sex. Similarly, fetal ultrasound isn't recommended solely for the purpose of producing keepsake videos or pictures. If your health care provider doesn' ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... and movement of the body's internal organs, as well as blood flowing through blood vessels. Ultrasound imaging is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... nodule felt by a physician during a routine physical exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides real-time ...

  1. Prostate Ultrasound

    Medline Plus

    Full Text Available ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ... well on x-ray images. Ultrasound causes no health problems and may be repeated as often as ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound exams are also used to monitor the health and development of an embryo or fetus during ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the ... the transducer (the device placed on the patient's skin to send and receive the returning sound waves), ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... probe) and ultrasound gel placed directly on the skin. High-frequency sound waves are transmitted from the ... the transducer (the device placed on the patient's skin to send and receive the returning sound waves), ...

  5. Prostate Ultrasound

    Medline Plus

    Full Text Available ... no ionizing radiation. Ultrasound scanning may be able to give a clearer picture of soft tissues that do ... understanding of the possible charges you will incur. Web page review process: This Web page is reviewed ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... use different transducers (with different capabilities) during a single exam. The transducer sends out high-frequency sound ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... collects the sounds that bounce back and a computer then uses those sound waves to create an ... Ultrasound scanners consist of a console containing a computer and electronics, a video display screen and a ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is located directly in front of the rectum, so the ultrasound exam is performed transrectally in order ... A follow-up examination may also be necessary so that any change in a known abnormality can ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the rectal wall is relatively insensitive to the pain in the region of the prostate. A biopsy ... needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... diagnose symptoms such as difficulty urinating or an elevated blood test result. It’s also used to investigate ... physical exam or prostate cancer screening exam. an elevated blood test result. difficulty urinating. Because ultrasound provides ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... The principles are similar to sonar used by boats and submarines. The ultrasound image is immediately visible ... principles involved in the sonar used by bats, ships and fishermen. When a sound wave strikes an ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... areas of the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. For ... make secure contact with the body and eliminate air pockets between the transducer and the skin that ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... a follow-up exam is done because a potential abnormality needs further evaluation with additional views or ... of soft tissues that do not show up well on x-ray images. Ultrasound causes no health ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... a follow-up exam is done because a potential abnormality needs further evaluation with additional views or ... of soft tissues that do not show up well on x-ray images. Ultrasound is the preferred ...

  17. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is smaller than the standard speculum used when performing a Pap test . A protective cover is placed ... of soft tissues that do not show up well on x-ray images. Ultrasound is the preferred ...

  18. Prostate Ultrasound

    Medline Plus

    Full Text Available ... scanning or sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on ... to do the scanning. The transducer is a small hand-held device that resembles a microphone, attached ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... scanning or sonography , involves the use of a small transducer (probe) and ultrasound gel placed directly on ... the child prior to the exam. Bringing books, small toys, music or games can help to distract ...

  20. Prostate Ultrasound

    Medline Plus

    Full Text Available ... less than 20 minutes. top of page What will I experience during and after the procedure? Ultrasound ... in the region of the prostate. A biopsy will add time to the procedure. Rarely, a small ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ultrasound images are reviewed. top of page What will I experience during and after the procedure? For ... in the region of the prostate. A biopsy will add time to the procedure. If a Doppler ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... arteries and veins in the abdomen, arms, legs, neck and/or brain (in infants and children) or ... diagnose symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the best way to see if treatment is working or if a finding is stable or changed ...

  4. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... and development of an embryo or fetus during pregnancy. See the Obstetrical Ultrasound page for more information . ... move through vessels. The movement of blood cells causes a change in pitch of the reflected sound ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... abdomen, arms, legs, neck and/or brain (in infants and children) or within various body organs such ... and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time imaging, making it a ...

  6. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ... barium exams, CT scanning , and MRI are the methods of choice in such a setting. Large patients ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... move through vessels. The movement of blood cells causes a change in pitch of the reflected sound ...

  8. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... requested the exam. Usually, the referring physician or health care provider will share the results with you. ...

  10. Ultrasound imaging

    International Nuclear Information System (INIS)

    Wells, P.N.T.

    1983-01-01

    Ultrasound is a form of energy which consists of mechanical vibrations the frequencies of which are so high that they are above the range of human hearing. The lower frequency limit of the ultrasonic spectrum may generally be taken to be about 20 kHz. Most biomedical applications of ultrasound employ frequencies in the range 1-15 MHz. At these frequencies, the wavelength is in the range 1.5 - 0.1 mm in soft tissues, and narrow beams of ultrasound can be generated which propagate through such tissues without excessive attenuation. This chapter begins with brief reviews of the physics of diagnostic ultrasound pulse-echo imaging methods and Doppler imaging methods. The remainder of the chapter is a resume of the applications of ultrasonic imaging to physiological measurement

  11. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow- ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ...

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow- ... Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... be asked to drink water prior to the examination to fill your bladder. Leave jewelry at home ... those sound waves to create an image. Ultrasound examinations do not use ionizing radiation (as used in ...

  14. Prostate Ultrasound

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Prostate Cancer top of page ... to Ultrasound - Prostate Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... with measurements acquired as needed for any treatment planning. detect an abnormal growth within the prostate. help ... end of their bowel (rectum) removed during prior surgery are not good candidates for ultrasound of the ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... tip of the transducer is smaller than the standard speculum used when performing a Pap test . A ... both sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... prostate gland and to help diagnose symptoms such as difficulty urinating or an elevated blood test result. ... image. Ultrasound examinations do not use ionizing radiation (as used in x-rays ), thus there is no ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... in the abdomen, arms, legs, neck and/or brain (in infants and children) or within various body organs ... or uterine cancers A transvaginal ultrasound is usually performed to view ...

  19. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is enlarged, also known as benign prostatic hyperplasia (BPH) , with measurements acquired as needed for any treatment ... caption Related Articles and Media Benign Prostatic Hyperplasia (BPH) (Enlargement of the Prostate) Prostate Cancer Ultrasound- and ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the exam. Bringing books, small toys, music or games can help to distract the child and make ... modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound provides real-time ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... uterine cavity . Three-dimensional (3-D) ultrasound permits evaluation of the uterus and ovaries in planes that ... a special study usually done to provide detailed evaluation of the prostate gland, involves inserting a specialized ...

  2. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... the examination process. To ensure a smooth experience, it often helps to explain the procedure to the ... on the amplitude (loudness), frequency (pitch) and time it takes for the ultrasound signal to return from ...

  3. Prostate Ultrasound

    Medline Plus

    Full Text Available ... difficulty urinating or an elevated blood test result. It’s also used to investigate a nodule found during ... difficulty urinating. Because ultrasound provides real-time images, it also can be used to guide procedures such ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on ... and Resources RTAnswers.org Radiation Therapy for Prostate Cancer top of page This page was reviewed on ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects on ... and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... rectum. top of page What are some common uses of the procedure? A transrectal ultrasound of the ... is done because a potential abnormality needs further evaluation with additional views or a special imaging technique. ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... legs, neck and/or brain (in infants and children) or within various body organs such as the ... tumors other disorders of the urinary bladder In children, pelvic ultrasound can help evaluate: pelvic masses pelvic ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... uterus). Sonohysterography allows for a more in-depth investigation of the uterine cavity . Three-dimensional (3-D) ... to-use and less expensive than other imaging methods. Ultrasound imaging is extremely safe and does not ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... is Pelvic Ultrasound Imaging? What are some common uses of the procedure? How should I prepare? What does the equipment look like? How does the procedure work? How is the procedure performed? What will I ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... quickly. The ultrasound exam room may have a television. Feel free to ask for your child's favorite ... display screen that looks like a computer or television monitor. The image is created based on the ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... Images related to Ultrasound - Prostate Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Images related to Ultrasound - Pelvis Sponsored by Please note RadiologyInfo.org is not a medical facility. Please ... is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society of ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... symptoms experienced by women such as: pelvic pain abnormal vaginal bleeding other menstrual problems Ultrasound exams also ... endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some physicians also use 3-D ...

  14. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... The ultrasound exam room may have a television. Feel free to ask for your child's favorite channel. ... performed over an area of tenderness, you may feel pressure or minor pain from the transducer. Once ...

  15. Prostate Ultrasound

    Medline Plus

    Full Text Available ... also known as benign prostatic hyperplasia (BPH) , with measurements acquired as needed for any treatment planning. detect ... areas of the body while other areas, especially air-filled lungs, are poorly suited for ultrasound. For ...

  16. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovarian cysts and uterine fibroids ovarian or uterine cancers A transvaginal ultrasound is usually performed to view ... detect: uterine anomalies uterine scars endometrial polyps fibroids cancer, especially in patients with abnormal uterine bleeding Some ...

  17. Prostate Ultrasound

    Medline Plus

    Full Text Available ... rectum. top of page What are some common uses of the procedure? A transrectal ultrasound of the ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  18. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... kidneys. top of page What are some common uses of the procedure? In women, a pelvic ultrasound ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  19. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  20. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... sends out high-frequency sound waves (that the human ear cannot hear) into the body and then ... ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... various body organs such as the liver or kidneys. top of page What are some common uses ... women, a pelvic ultrasound exam can help identify: kidney stones bladder tumors other disorders of the urinary ...

  2. Prostate Ultrasound

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ships ...

  3. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... echoes from the tissues in the body. The principles are similar to sonar used by boats and ... work? Ultrasound imaging is based on the same principles involved in the sonar used by bats, ships ...

  4. Prostate Ultrasound

    Medline Plus

    Full Text Available ... is at high risk for cancer. In this case, a biopsy is performed and an ultrasound probe ... will share the results with you. In some cases, the radiologist may discuss results with you at ...

  5. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... ovaries. Transvaginal ultrasound also evaluates the myometrium (muscular walls of the uterus). Sonohysterography allows for a more ... needle insertion) is usually minimal because the rectal wall is relatively insensitive to the pain in the ...

  6. Prostate Ultrasound

    Medline Plus

    Full Text Available ... uses sound waves to produce pictures of a man’s prostate gland and to help diagnose symptoms such ... also called transrectal ultrasound, provides images of a man's prostate gland and surrounding tissue. The exam typically ...

  7. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... pain ambiguous genitalia and anomalies of pelvic organs early or delayed puberty in girls Pelvic ultrasound is ... sensitive to motion, and an active or crying child can prolong the examination process. To ensure a ...

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... consist of a console containing a computer and electronics, a video display screen and a transducer that ... the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn babies. Ultrasound ...

  9. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... insertion. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  10. Prostate Ultrasound

    Medline Plus

    Full Text Available ... gel. top of page How does the procedure work? Ultrasound imaging is based on the same principles ... the transducer is pressed against the skin, it directs small pulses of inaudible, high-frequency sound waves ...

  11. Prospective study of Centurion® versus Infiniti® phacoemulsification systems: surgical and visual outcomes

    Directory of Open Access Journals (Sweden)

    Lawrence J. Oh

    2017-11-01

    Full Text Available AIM: To evaluate surgical outcomes (SOs and visual outcomes (VOs in cataract surgery comparing the Centurion® phacoemulsification system (CPS with the Infiniti® phacoemulsification system (IPS. METHODS: Prospective, consecutive study in a single-site private practice. Totally 412 patients undergoing cataract surgery with either the CPS using the 30-degree balanced® tip (n=207 or the IPS using the 30-degree Kelman® tip (n=205. Intraoperative and postoperative outcomes were documented prospectively up to one month follow-up. Nuclear sclerosis (NS grade, cumulated dissipated energy (CDE, preoperative corrected distance visual acuity (CDVA, and CDVA at one month were recorded. RESULTS: CDE was 13.50% less in the whole CPS compared with the whole IPS subcohort. In eyes with NS grade III or greater, CDE was 28.87% less with CPS (n=70 compared with IPS (n=44 (P=0.010. Surgical complications were not statistically different between the two subcohorts (P=0.083, but in the one case of vitreous loss using the CPS, CDVA of 6/4 was achieved at one month. The mean CDVAs (VOs at one month for NS grade III and above cataracts were -0.17 logMAR (6/4.5 in the CPS and -0.15 logMAR (6/4.5 in the IPS subcohort respectively (P=0.033. CONCLUSION: CDE is 28.87% less, and VOs are significantly improved, in denser cataracts in the CPS compared with the IPS. The authors recommend the CPS for cases with denser nuclei.

  12. Prospective study of Centurion® versus Infiniti® phacoemulsification systems: surgical and visual outcomes.

    Science.gov (United States)

    Oh, Lawrence J; Nguyen, Chu Luan; Wong, Eugene; Wang, Samuel S Y; Francis, Ian C

    2017-01-01

    To evaluate surgical outcomes (SOs) and visual outcomes (VOs) in cataract surgery comparing the Centurion ® phacoemulsification system (CPS) with the Infiniti ® phacoemulsification system (IPS). Prospective, consecutive study in a single-site private practice. Totally 412 patients undergoing cataract surgery with either the CPS using the 30-degree balanced ® tip ( n =207) or the IPS using the 30-degree Kelman ® tip ( n =205). Intraoperative and postoperative outcomes were documented prospectively up to one month follow-up. Nuclear sclerosis (NS) grade, cumulated dissipated energy (CDE), preoperative corrected distance visual acuity (CDVA), and CDVA at one month were recorded. CDE was 13.50% less in the whole CPS compared with the whole IPS subcohort. In eyes with NS grade III or greater, CDE was 28.87% less with CPS ( n =70) compared with IPS ( n =44) ( P =0.010). Surgical complications were not statistically different between the two subcohorts ( P =0.083), but in the one case of vitreous loss using the CPS, CDVA of 6/4 was achieved at one month. The mean CDVAs (VOs) at one month for NS grade III and above cataracts were -0.17 logMAR (6/4.5) in the CPS and -0.15 logMAR (6/4.5) in the IPS subcohort respectively ( P =0.033). CDE is 28.87% less, and VOs are significantly improved, in denser cataracts in the CPS compared with the IPS. The authors recommend the CPS for cases with denser nuclei.

  13. Experience in the diagnostic and surgical treatment of pancreatic pseudocysts

    Directory of Open Access Journals (Sweden)

    N. G. Golovko

    2015-10-01

    Full Text Available Actuality. Problem of surgical treatment of pancreatic pseudocysts is actual and debatable. The incidence of pancreatic pseudocysts is 0.5–1 per 100 000 adults per year, and in the overall incidence it reaches 1.6% –4.5%. Aim. Surgical treatment results of 34 patients with pancreatic pseudocysts were analyzed to improve results of diagnostic and surgical management of pancreatic pseudocests. Methods and results. Ultrasound scan combined with computer tomography were used for pancreatic pseudocysts diagnostic. Pancreatic pseudocysts surgical treatment was performed by minimally invasive percutaneous techniques and laparotomic surgery. Laparotomy operations were performed in 27 patients. The structure of operations was follow: external drainage of pseudocysts - 11 patients, 2 of them by minilaparotomy access, pseudocyst jejunostomy by Roux – 9 patients, pseudocyst jejunostomy with entero-enteroanastamosis by Brown – 3 patients, pseudocyst gastrostomy and pseudocyst duodenostomy – in 2 patients. Percutaneous external drainage of pancreatic pseudocysts under ultrasound control was performed in 7 patients. Indications for external percutaneous needle drainage of pancreatic pseudocysts under ultrasound control were: presence of a secure acoustic windows, lack of communication with the pancreatic pseudocysts ductal system, pseudocyst cavity diameter greater than 60 mm with wall thickness more than 3–4 mm, presence of the severe comorbidity and high operational and anesthetic risk (III–IV class ASA. Conclusions. Analysis of early treatment results (3–6 months found that pancreatic pseudocysts minimally invasive percutaneous puncture external drainage use in combination with ultrasound control, in addition to laparotomic operation, allows to achieve excellent and good results in 91.1% of patients.

  14. The galenic venous system: Surgical anatomy and its angiographic and magnetic resonance venographic correlations

    International Nuclear Information System (INIS)

    Kilic, Tuerker; Ozduman, Koray; Cavdar, Safiye; Oezek, M. Memet; Pamir, M. Necmettin

    2005-01-01

    Objective: This study aims at evaluating the adequacy of digital subtraction angiography and magnetic resonance venography in imaging of the galenic venous system for surgical planning of approaches to the pineal region. Anatomical dissections were carried out in 10 cadavers of several age groups and these were compared to imaging findings in 10 living subjects. Methods: The presence or absence of 10 predetermined veins or vein groupings belonging to the galenic venous system were prospectively analyzed in 10 cadaver dissections and imaging findings of 10 age matched human subjects. The studied vessels were the vein of galen, the internal cerebral veins, both basal vein of Rosenthals, internal occipital vein, occipitotemporal veins, precentral cerebellar veins, tectal veins, pineal veins, superior vermian veins (including superior cerebellar veins (SCVs)) and posterior pericallosal veins. Each of the subjects had both digital subtraction angiography and magnetic resonance venography studies performed. Diagnostic digital subtraction angiography was performed using the transfemoral route and the venous phase was used for the study. Magnetic resonance venography was performed in 1.5 T MRI equipment using the 2D-TOF sequence. All studies were reported to be normal. Results: There was wide variation in the anatomy of the galenic venous system. There were interpersonal, intrapersonal and age related variations. Both the digital subtraction angiography and the magnetic resonance venography were efficient at demonstrating large veins. However, smaller veins were less readily demonstrated in either study. The general sensitivities of the digital subtraction angiography and the magnetic resonance venography for the galenic venous system were 45.5% and 32.5%, respectively. Surgically important veins were missed in most studies. Conclusions: Anatomically, the galenic venous system is highly variable. This variability is caused by interpersonal, intrapersonal and age related

  15. The galenic venous system: Surgical anatomy and its angiographic and magnetic resonance venographic correlations

    Energy Technology Data Exchange (ETDEWEB)

    Kilic, Tuerker [Marmara University, Department of Neurosurgery, PK 53, Maltepe, 81532 Istanbul (Turkey) and Marmara University, Department of Anatomy, Istanbul (Turkey)]. E-mail: turkilic@tnn.net; Ozduman, Koray [Marmara University, Department of Neurosurgery, PK 53, Maltepe, 81532 Istanbul (Turkey); Cavdar, Safiye [Marmara University, Department of Anatomy, Istanbul (Turkey); Oezek, M. Memet [Marmara University, Department of Neurosurgery, PK 53, Maltepe, 81532 Istanbul (Turkey); Pamir, M. Necmettin [Marmara University, Department of Neurosurgery, PK 53, Maltepe, 81532 Istanbul (Turkey)

    2005-11-01

    Objective: This study aims at evaluating the adequacy of digital subtraction angiography and magnetic resonance venography in imaging of the galenic venous system for surgical planning of approaches to the pineal region. Anatomical dissections were carried out in 10 cadavers of several age groups and these were compared to imaging findings in 10 living subjects. Methods: The presence or absence of 10 predetermined veins or vein groupings belonging to the galenic venous system were prospectively analyzed in 10 cadaver dissections and imaging findings of 10 age matched human subjects. The studied vessels were the vein of galen, the internal cerebral veins, both basal vein of Rosenthals, internal occipital vein, occipitotemporal veins, precentral cerebellar veins, tectal veins, pineal veins, superior vermian veins (including superior cerebellar veins (SCVs)) and posterior pericallosal veins. Each of the subjects had both digital subtraction angiography and magnetic resonance venography studies performed. Diagnostic digital subtraction angiography was performed using the transfemoral route and the venous phase was used for the study. Magnetic resonance venography was performed in 1.5 T MRI equipment using the 2D-TOF sequence. All studies were reported to be normal. Results: There was wide variation in the anatomy of the galenic venous system. There were interpersonal, intrapersonal and age related variations. Both the digital subtraction angiography and the magnetic resonance venography were efficient at demonstrating large veins. However, smaller veins were less readily demonstrated in either study. The general sensitivities of the digital subtraction angiography and the magnetic resonance venography for the galenic venous system were 45.5% and 32.5%, respectively. Surgically important veins were missed in most studies. Conclusions: Anatomically, the galenic venous system is highly variable. This variability is caused by interpersonal, intrapersonal and age related

  16. A simple weighted scoring system to guide surgical decision-making in patients with parapneumonic pleural effusion.

    Science.gov (United States)

    Chang, Che-Chia; Chen, Tzu-Ping; Yeh, Chi-Hsiao; Huang, Pin-Fu; Wang, Yao-Chang; Yin, Shun-Ying

    2016-11-01

    The selection of ideal candidates for surgical intervention among patients with parapneumonic pleural effusion remains challenging. In this retrospective study, we sought to identify the main predictors of surgical treatment and devise a simple scoring system to guide surgical decision-making. Between 2005 and 2014, we identified 276 patients with parapneumonic pleural effusion. Patients in the training set (n=201) were divided into two groups according to their treatment modality (non-surgery vs. surgery). Using multivariable logistic regression analysis, we devised a scoring system to guide surgical decision-making. The score was subsequently validated in an independent set of 75 patients. A white blood cell count >13,500/µL, pleuritic pain, loculations, and split pleura sign were identified as independent predictors of surgical treatment. A weighted score based on these factors was devised, as follows: white blood cell count >13,500/µL (one point), pleuritic pain (one point), loculations (two points), and split pleura sign (three points). A score >4 was associated with a surgical approach with a sensitivity of 93.4%, a specificity of 82.4%, and an area under curve (AUC) of 0.879 (95% confidence interval: 0.828-0.930). In the validation set, a sensitivity of 94.3% and a specificity of 79.6% were found (AUC=0.869). The proposed scoring system reliably identifies patients with parapneumonic pleural effusion who are candidates for surgery. Pending independent external validation, our score may inform the appropriate use of surgical interventions in this clinical setting.

  17. Study of the Operational Safety of a Vascular Interventional Surgical Robotic System

    Directory of Open Access Journals (Sweden)

    Jian Guo

    2018-03-01

    Full Text Available This paper proposes an operation safety early warning system based on LabView (2014, National Instruments Corporation, Austin, TX, USA for vascular interventional surgery (VIS robotic system. The system not only provides intuitive visual feedback information for the surgeon, but also has a safety early warning function. It is well known that blood vessels differ in their ability to withstand stress in different age groups, therefore, the operation safety early warning system based on LabView has a vascular safety threshold function that changes in real-time, which can be oriented to different age groups of patients and a broader applicable scope. In addition, the tracing performance of the slave manipulator to the master manipulator is also an important index for operation safety. Therefore, we also transformed the slave manipulator and integrated the displacement error compensation algorithm in order to improve the tracking ability of the slave manipulator to the master manipulator and reduce master–slave tracking errors. We performed experiments “in vitro” to validate the proposed system. According to previous studies, 0.12 N is the maximum force when the blood vessel wall has been penetrated. Experimental results showed that the proposed operation safety early warning system based on LabView combined with operating force feedback can effectively avoid excessive collisions between the surgical catheter and vessel wall to avoid vascular puncture. The force feedback error of the proposed system is maintained between ±20 mN, which is within the allowable safety range and meets our design requirements. Therefore, the proposed system can ensure the safety of surgery.

  18. A 3D freehand ultrasound system for multi-view reconstructions from sparse 2D scanning planes.

    Science.gov (United States)

    Yu, Honggang; Pattichis, Marios S; Agurto, Carla; Beth Goens, M

    2011-01-20

    A significant limitation of existing 3D ultrasound systems comes from the fact that the majority of them work with fixed acquisition geometries. As a result, the users have very limited control over the geometry of the 2D scanning planes. We present a low-cost and flexible ultrasound imaging system that integrates several image processing components to allow for 3D reconstructions from limited numbers of 2D image planes and multiple acoustic views. Our approach is based on a 3D freehand ultrasound system that allows users to control the 2D acquisition imaging using conventional 2D probes.For reliable performance, we develop new methods for image segmentation and robust multi-view registration. We first present a new hybrid geometric level-set approach that provides reliable segmentation performance with relatively simple initializations and minimum edge leakage. Optimization of the segmentation model parameters and its effect on performance is carefully discussed. Second, using the segmented images, a new coarse to fine automatic multi-view registration method is introduced. The approach uses a 3D Hotelling transform to initialize an optimization search. Then, the fine scale feature-based registration is performed using a robust, non-linear least squares algorithm. The robustness of the multi-view registration system allows for accurate 3D reconstructions from sparse 2D image planes. Volume measurements from multi-view 3D reconstructions are found to be consistently and significantly more accurate than measurements from single view reconstructions. The volume error of multi-view reconstruction is measured to be less than 5% of the true volume. We show that volume reconstruction accuracy is a function of the total number of 2D image planes and the number of views for calibrated phantom. In clinical in-vivo cardiac experiments, we show that volume estimates of the left ventricle from multi-view reconstructions are found to be in better agreement with clinical

  19. The Role of Radio Frequency Detection System Embedded Surgical Sponges in Preventing Retained Surgical Sponges: A Prospective Evaluation in Patients Undergoing Emergency Surgery.

    Science.gov (United States)

    Inaba, Kenji; Okoye, Obi; Aksoy, Hande; Skiada, Dimitra; Ault, Glenn; Sener, Stephen; Lam, Lydia; Benjamin, Elizabeth; Demetriades, Demetrios

    2016-10-01

    To prospectively evaluate the ability of radio frequency detection (RFD) system-embedded sponges to mitigate the incidence of retained surgical sponges (RSS) after emergency surgery. Emergency surgery patients are at high risk for retained foreign bodies. All emergent trauma and nontrauma cavitary operations over a 5-year period (January 2010-December 2014) were prospectively enrolled. For damage-control procedures, only the definitive closure was included. RFD sponges were used exclusively throughout the study period. Before closure, the sponge and instrument count was followed by RFD scanning and x-ray evaluation for retained sponges. RSS and near-misses averted using the RFD system were analyzed. In all, 2051 patients [median (range)], aged 41 (1-101) years, 72.2% male, 46.8% trauma patients, underwent 2148 operations (1824 laparotomy, 100 thoracotomy, 30 sternotomy, and 97 combined). RFD detected retained sponges in 11 (0.5%) patients (81.8%laparotomy, 18.2% sternotomy) before cavitary closure. All postclosure x-rays were negative. No retained sponges were missed by the RFD system. Body mass index was 29 (23-43), estimated blood loss 1.0 L (0-23), and operating room time 160 minutes (71-869). Procedures started after 18:00 to 06:00 hours in 45.5% of the patients. The sponge count was incorrect in 36.4%, not performed due to time constraints in 45.5%, and correct in 18.2%. The additional cost of using RFD-embedded disposables was $0.17 for a 4X18 laparotomy sponge and $0.46 for a 10 pack of 12ply, 4X8. Emergent surgical procedures are high-risk for retained sponges, even when sponge counts are performed and found to be correct. Implementation of a RFD system was effective in preventing this complication and should be considered for emergent operations in an effort to improve patient safety.

  20. Development of a surgical site infection (SSI) surveillance system, calculation of SSI rates and specification of important factors affecting SSI in a digestive organ surgical department.

    Science.gov (United States)

    Kimura, Koji; Sawa, Akihiro; Akagi, Shinji; Kihira, Kenji

    2007-06-01

    We have developed an original system to conduct surgical site infection (SSI) surveillance. This system accumulates SSI surveillance information based on the National Nosocomial Infections Surveillance (NNIS) System and the Japanese Nosocomial Infections Surveillance (JNIS) System. The features of this system are as follows: easy input of data, high generality, data accuracy, SSI rate by operative procedure and risk index category (RIC) can be promptly calculated and compared with the current NNIS SSI rate, and the SSI rates and accumulated data can be exported electronically. Using this system, we monitored 798 patients in 24 operative procedure categories in the Digestive Organs Surgery Department of Mazda Hospital, Mazda Motor Corporation, from January 2004 through December 2005. The total number and rate of SSI were 47 and 5.89%, respectively. The SSI rates of 777 patients were calculated based on 15 operative procedure categories and Risk Index Categories (RIC). The highest SSI rate was observed in the rectum surgery of RIC 1 (30%), followed by the colon surgery of RIC3 (28.57%). About 30% of the isolated infecting bacteria were Enterococcus faecalis, Staphylococcus aureus, Klebsiella pneumoniae, Pseudomonas aeruginosa, and Escherichia coli. Using quantification theory type 2, the American Society of Anesthesiology score (4.531), volume of hemorrhage under operation (3.075), wound classification (1.76), operation time (1.352), and history of diabetes (0.989) increased to higher ranks as factors for SSI. Therefore, we evaluated this system as a useful tool in safety control for operative procedures.