WorldWideScience

Sample records for surgical suture materials

  1. Choice of surgical suture material used in oral cavity: Clinical study

    Directory of Open Access Journals (Sweden)

    Mirković Siniša

    2010-01-01

    Full Text Available Introduction. Historical data on closing and suturing of surgical wounds describe a wide range of various suture materials. The choice of the surgical catgut, i.e. type and diameter, depends on the localization, characteristics and condition of the tissue to be treated. From the stand-point of oral-surgical practice the following clinical parameters are of the outstanding importance regarding the choice of suture material: accumulation of soft deposits on the sutures, decubitus of the adjacent soft tissues and dehiscence of the operative wound. Aim. The aim of this research was to determine the correlation between different types of suture materials and accumulation of soft deposits on the sutures, decubitus of the adjacent soft tissues and dehiscence of the operative wound. Material and methods. Our prospective clinical study included 150 patients distributed into three groups of 50 subjects. The surgical procedure performed on each patient involved resection (apicoectomy of the tooth root end in the intercanine sector of the upper jaw. The following suture materials were applied: BLACK SILK 5-0, NYLON 5-0 and VICRYL 5-0. The effects of the selected sutures were evaluated by using several parameters: accumulation of soft deposits, wound dehiscence and decubitus of the adjacent soft tissues. The effects of the applied sutures were recorded on days 2, 5 and 7 after the surgery. Conclusion. The comparison of cited parameters of the investigated materials after suture of oral cavity mucosa revealed that none of the used material was ideal; however, a certain preference might be given to the synthetic monofilament suture materials.

  2. Influence of different types of surgical suture materials on mehanical damage of oral mucosa

    Directory of Open Access Journals (Sweden)

    Mirković Siniša

    2011-01-01

    Full Text Available Introduction. Throughout history many kinds of different suture materials have been used for closing and suturing surgical wounds. Medical literature describes four basic characteristics of suture material: knot safety, tensile strength, tissue reaction and wound safety. The tissue reaction is reflected in an inflammatory response, which, though minimal, occurs during first two to seven days after implanting suture into the tissue. The aim of this research was to investigate whether different suture materials affect the development of decubital damage of oral mucosa, which to a great extent can compromise the process of wound healing. Material and methods. The investigation was designed as a prospective clinical study including 150 patients of both genders, aged between 25 and 60. The patients were distributed into three groups of 50 persons. The suture Black Silk was used in the first group, designated as a control group. Nylon and Vicril were used in the second and third group, i.e. experimental groups, respectively. Decubital damage of the surrounding soft tissues was the main parameter for monitoring the effects of selected suture materials on the oral mucosa. Conclusion. The comparison of results obtained for the investigated suture materials after suturing oral mucosa revealed that certain advan­tage could be given to synthetic monofilament suture materials

  3. Evaluation of four suture materials for surgical incision closure in Siberian sturgeon

    Science.gov (United States)

    Boone, S. Shaun; Hernandez, Sonia M.; Camus, Alvin C.; Peterson, Douglas C.; Jennings, Cecil A.; Shelton, James L.; Divers, Stephen J.

    2015-01-01

    The visual and microscopic tissue reactions to the absorbable monofilament Monocryl, absorbable monofilament triclosan-coated Monocryl-Plus, absorbable multifilament Vicryl, and nonabsorbable monofilament Prolene were evaluated for their use of surgical closure in Siberian Sturgeon Acipenser baerii. Postoperative assessments were conducted at 1, 2, 8, 12, and 26 and 55 weeks to visually evaluate the surgical incision for suture retention, incision healing, erythema, and swelling. Incisions were also assessed microscopically at 1, 2, and 8 weeks for necrosis, inflammation, hemorrhage, and fibroplasia. The results indicated that incisions closed with either Vicryl or Prolene suture materials were more likely to exhibit more erythema or incomplete healing compared with those closed with Monocryl or Monocryl-Plus. The surgical implantation of a transmitter in the coelomic cavity did not significantly affect the response variables among the four suture materials. Monocryl or Monocryl-Plus were equally effective and superior to other suture materials used for closing surgical incisions in Siberian Sturgeon or closely related species of sturgeon. Furthermore, Monocryl or Monocryl-Plus may decrease the risk of transmitter expulsion through the incision, as surgical wounds appear to heal faster and exhibit less erythema compared with those closed with Vicryl.

  4. Influence of different types of surgical suture material on the intensity of tissue reaction in oral cavity

    Directory of Open Access Journals (Sweden)

    Mirković Siniša M.

    2008-01-01

    Full Text Available Throughout the history the most diverse suture material have been used for closing and suturing surgical wounds. The four basic features of suture material are described: knot safety, stretch capacity, tissue reactivity and wound safety. Tissue reaction, even the minimum one, which develops during the first to seven days after applying the suture in the tissue. The aim of this study was to investigate influence of a monofilament suture material (nylon on the intensity of local tissue reaction in experimental conditions, and to compare it with the multifilament suture used in the routine practice of oral surgery (silk. This investigation is a prospective experimental study carried out on Wistar rats. The experiment included 30 animals, in which Black Silk (thickness 4-1 and Nylon (thickness 4-0 were applied in the upper and lower jaw, respectively. To monitor tissue reaction on different suture materials the following parameters were used: coagulum formation, presence of polymorphonuclear leukocytes, presence of macrophages and granuloma, formation of epithelial bridge and connective tissue, collagen synthesis, granulomatous tissue formation and presence of fibrous tissue. After comparing parameters for the intensity of tissue reaction to the investigate suture materials by suturing the oral mucosa, certain advantage could be given to the monofilament suture materials.

  5. Influence of surgical sutures on wound healing

    Directory of Open Access Journals (Sweden)

    Mirković Siniša

    2010-01-01

    Full Text Available Historical data on closing and suturing of surgical wounds describe a wide range of various suture materials. The choice of the surgical catgut, i.e. the type and diameter, depends on the locality, characteristics and condition of the tissue to be treated. From the standpoint of oral-surgical practice the following clinical parameters are of outstanding importance with respect to the selection of suture material: accumulation of soft deposits on the sutures, score of the adjacent soft tissues and dehiscence of the operative wound. Our prospective clinical study included 150 patients distributed into three groups of 50 subjects. The surgical procedure performed on each patient involved resection (apicotomy of the tooth root end in the intercanine sector of the upper jaw. The following suture materials were applied: Black Silc 5-0, Nylon 5-0 and Vicryl 5-0. The effects of the selected sutures were evaluated according to the wound dehiscence. The effects of the applied sutures were recorded on Days 2, 5 and 7 after the surgery. The comparison of cited parameters of the investigated materials after suturing the oral mucosa revealed that none of the used material was ideal; however, a certain advantage might be given to the synthetic monofilament suture materials.

  6. Induction of immune gene expression and inflammatory mediator release by commonly used surgical suture materials: an experimental in vitro study.

    Science.gov (United States)

    Lock, Alistair M; Gao, Ryan; Naot, Dorit; Coleman, Brendan; Cornish, Jillian; Musson, David S

    2017-01-01

    Surgeons have a range of materials to choose from to complete wound closure, yet surprisingly very little is still known about the body's immune response to the suture materials in current use. The growing literature of adverse suture material reactions provided the objective of this study, to use in vitro assays to quantify levels of inflammation produced by seven commonly used suture materials in surgical procedures. Human monocyte/macrophage THP-1 cells were exposed to suture materials for 1, 3 and 5 days. Gene expression and protein secretion of six inflammatory cytokines and two cell surface markers were assessed using qPCR and ELISA respectively, with LPS exposure providing a positive control. Furthermore, a IL-1β/IL-1RA marker ratio was assessed to determine the balance between pro-/anti-inflammatory expression. The findings from our in vitro study suggest that four commonly used suture materials cause upregulation of pro-inflammatory markers indicative of an early foreign body reaction, with no balance from anti-inflammatory markers. As prolonged early pro-inflammation is known to produce delayed wound healing responses, the knowledge produced from this study has potential to improve informed surgical decision making and patient safety. This work has the capability to reduce suture-related adverse immune reactions, and therefore positively affect patient outcomes.

  7. [Production of superoxide anion radical and nitric oxide in renal tissues sutured with different surgical suture material].

    Science.gov (United States)

    Kostenko, V O; Tsebrzhins'kii, O I

    2000-01-01

    The generation of superoxide anion radicals (in mitochondria, microsomes and under respiratory burst of leucocytes) and nitric oxide (NO) in renal tissue has been studied in the experiment with white rats, which had been carried out nephrotomy with following usage for suture such absorbable surgical threads as plain and chromic catgut, biofil (of dura mater spinalis of the cattle), Dexon II (polyglycolic acid) and biofil modified with aethonium, succinate and mexidol. The research proves the use of plai and chromic catgut leads to the development longer oxidative stress with increasing of cytotoxic agents production (superoxide anion and NO). The risk of longitudinal oxidative stress decreases under the use of biofil suture modified with biological active compounds (aethonium, succinate and mexidol). In this case, the generation of superoxide anion radicals in mitochondria and microsomes is normalised earlier. The superoxide generation with respiratory burst of leucocytes and NO production decreases in 14 day of postoperative period under the use of biofil suture modified with succinate and mexidol.

  8. Evaluation of surgical implantation of electronic tags in European eel and effects of different suture materials

    DEFF Research Database (Denmark)

    Thorstad, Eva B.; Økland, Finn; Westerberg, Håkan

    2013-01-01

    Effects of implanting data-storage tags in European eel, Anguilla anguilla, and the suitability of different suture materials (braided permanent silk, permanent monofilament, absorbable and absorbable antibacterial) were examined. The tags consisted of an electronic unit and three floats on a wire....... Antibacterial treatment had no effect on inflammation or healing rates. After 6 months, the tag started to become expelled through the incision in five fish (12%). The internal reaction appeared stronger around the floats, suggesting that the coating material of the floats created a tissue reaction, which...

  9. Mechanical performance of gamma irradiated surgical sutures

    Energy Technology Data Exchange (ETDEWEB)

    Pino, Eddy S.; Rela, Paulo P. [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil)

    2000-07-01

    Surgical sutures are medical devices made of natural or synthetic polymeric materials that, due to its end-use, have to be sterilized. Historically, the sterilization by heat or using ethylene oxide had presented so numerous drawbacks that today the non-pollutant radiation sterilization has become a well established sterilization process, that brings, environmental, technical, and economical advantages. The amount of irradiation doses required for sterilization of health care products is 25 kGy in most instances to achieve the necessary sterility assurance level. As high energy radiation produces modifications in the molecular structure of organic materials with changes in its mechanical properties, the aim of this work was to evaluate the mechanical behavior of surgical sutures under irradiation. Silk, polyamide and catgut sutures were gamma irradiated up to doses of 50 kGy in an industrial irradiation sterilization plant. Afterwards, these sutures were mechanical tested for tensile strength under knot following the specifications of the NBR13904 draft standard, using the CTRD-INSTRON at IPEN. The mechanical lab results show that sutures made of Silk and Polyamide do not present any change in their mechanical performance up to the dose of 50 kGy. On the other hand, Catgut present mechanical stability up to 30 kGy and afterwards, a slight decrease in its tensile strength was detected. (author)

  10. Suture Materials in Ophthalmic Surgery

    OpenAIRE

    KÖHLE, Ülkü; Demir, Canser Yılmaz

    2003-01-01

    Suture materials is one of the basic subjects which every surgeon should know. The operation of suturing, sewing together two sides of a wound, is probably one of the oldest in the history of medicine. Its purpose is to aid healing as atraumatically as possible and it has mainly the mechanical effect of holding the wound edges together. Different suture materials have been manufactured. Each material is suited to different types of tissue, but all must posses certain character...

  11. Nonspecific iodine accumulation in surgical suture material mimicking follicular thyroid cancer bone metastasis in (131)I scintigraphy.

    Science.gov (United States)

    Winkens, Thomas; Nietzsche, Sandor; Gottschaldt, Michael; Freesmeyer, Martin

    2014-02-01

    A 23-year-old man with follicular thyroid carcinoma and cervical lymph node metastases showed a clear I focus on the skull after radioiodine therapy; therefore, an osseous metastasis was suspected. I and MRI fusion suggested the I focus to be adjacent to an epicranial suture from an early childhood trepanation for epidural hematoma. Radio-guided surgery found dark brown material to be the source of the radiation and successfully removed the material. Subsequent electron microscopy revealed a thread within the dark brown material, suggesting suture material as the cause of I accumulation.

  12. 21 CFR 878.5030 - Natural nonabsorbable silk surgical suture.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Natural nonabsorbable silk surgical suture. 878... Natural nonabsorbable silk surgical suture. (a) Identification. Natural nonabsorbable silk surgical suture... Bombycidae. Natural nonabsorbable silk surgical suture is indicated for use in soft tissue...

  13. ABDOMINAL CLOSURE WITH ANTI BACTERIAL COATED SUTURE MATERIALS AND ITS RELATION TO THE INCIDENCE OF POST OPERATIVE SUPERFICIAL SURGICAL SITE INFECTION RATES

    Directory of Open Access Journals (Sweden)

    Josephine Pudumai Selvi

    2017-07-01

    Full Text Available BACKGROUND Surgical site infection (SSI is an immense burden on healthcare resources even in the modern era of immaculate sterilization approaches and highly effective antibiotics. An estimated 234 million various surgical procedures, involving skin incisions requiring various types of wound closure techniques, are performed in the world, with the majority resulting in a wound healing by primary intention. Triclosan (5-chloro-2-(2, 4-dichlorophenoxy phenol is a broad-spectrum bactericidal agent that has been used for more than 40 years in various products, such as toothpaste and soaps. Higher concentrations of Triclosan work as a bactericide by attacking different structures in the bacterial cytoplasm and cell membrane. Use of Triclosan-coated sutures should theoretically result in the reduction of SSI. The aim of the study is to assess the abdominal closure with antibacterial coated suture materials and its relation to the incidence of post-operative superficial surgical site infection rates. MATERIALS AND METHODS The data will be collected from hospital records of surgery performed, post-operative daily progress notes and outpatient folders and telephonic conversations with patients after discharge. All patients undergoing laparotomy procedure for any cause. 100 patients divided as 50 in each group. RESULTS The positive outcome of infection (21.5% in patients using ordinary sutures was significantly differed with the positive outcome of infection (11.4% of Triclosan coated sutures. CONCLUSION In conclusion since there was a definite advantage inferred to the patients by using Triclosan coated polyglactin 910, it is the opinion of the researcher that Triclosan coated sutures has a role to play in reducing SSI in clean wounds and its use should be confined to areas where its application has proven benefits. However more studies should be done to clearly define its role and indications in surgery.

  14. Does UV disinfection compromise sutures? An evaluation of tissue response and suture retention in salmon surgically implanted with transmitters

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Ricardo W.; Brown, Richard S.; Deters, Katherine A.; Eppard, M. B.; Cooke, Steven J.

    2013-10-01

    Ultraviolet radiation (UVR) can be used as a tool to disinfect surgery tools used for implanting transmitters into fish. However, the use of UVR could possibly degrade monofilament suture material used to close surgical incisions. This research examined the effect of UVR on monofilament sutures to determine if they were compromised and negatively influenced tag and suture retention, incision openness, or tissue reaction. Eighty juvenile Chinook salmon Oncorhynchus tshawytscha were surgically implanted with an acoustic transmitter and a passive integrated transponder. The incision was closed with a single stitch of either a suture exposed to 20 doses of UV radiation (5 minute duration per dose) or a new, sterile suture. Fish were then held for 28 d and examined under a microscope at day 7, 14, 21 and 28 for incision openness, ulceration, redness, and the presence of water mold. There was no significant difference between treatments for incision openness, redness, ulceration or the presence of water mold on any examination day. On day 28 post-surgery, there were no lost sutures; however, 2 fish lost their transmitters (one from each treatment). The results of this study do not show any differences in negative influences such as tissue response, suture retention or tag retention between a new sterile suture and a suture disinfected with UVR.

  15. Frimand Needle Holder Reduces Suturing Time and Surgical Stress When Suturing in Palm Grip.

    Science.gov (United States)

    Frimand Rönnow, Carl-Fredrik; Jeppsson, Bengt; Thorlacius, Henrik

    2016-06-01

    Purpose The Frimand needle holder (FNH) was developed to facilitate palm grip suturing. In the present study, we wanted to examine the impact of the FNH compared with a conventional Hegar-styled needle holder (HSNH) on suture time and surgical stress. Methods Thirty-two surgeons were enrolled and they performed sets of 3 continuous sutures on a polyurethane pad with premarked insert and exit points and the time for suturing was measured. Surgical stress was quantified by having the surgeons to perform 10 release maneuvers with the FNH and the HSNH on a needle attached to a scale. The scale sent 5 values per second to a computer. The first measurement of each series was regarded as the starting weight and all subsequent measurements were either regarded as neutral, pressure or traction. The sum of these measurements represented total surgical stress. Results We found that all surgeons reduced their median suturing time by 16% when using FNH for palm grip suturing with no difference between junior and senior surgeons. Moreover, it was observed that FNH decreased median surgical stress by 62% for all surgeons performing palm grip suturing compared with a conventional HSNH. Conclusion We conclude that the FNH reduces suture time and surgical stress compared with HSNH when performing palm grip suturing. These findings warrant studies in surgical patients in order to evaluate the potential clinical impact of FNH.

  16. Needle Path Planning for Autonomous Robotic Surgical Suturing.

    Science.gov (United States)

    Jackson, Russell C; Cavuşoğlu, M Cenk

    2013-12-31

    This paper develops a path plan for suture needles used with solid tissue volumes in endoscopic surgery. The path trajectory is based on the best practices that are used by surgeons. The path attempts to minimize the interaction forces between the tissue and the needle. Using surgical guides as a basis, two different techniques for driving a suture needle are developed. The two techniques are compared in hardware experiments by robotically driving the suture needle using both of the motion plans.

  17. Surgical sutures filled with adipose-derived stem cells promote wound healing.

    Directory of Open Access Journals (Sweden)

    Ann Katharin Reckhenrich

    Full Text Available Delayed wound healing and scar formation are among the most frequent complications after surgical interventions. Although biodegradable surgical sutures present an excellent drug delivery opportunity, their primary function is tissue fixation. Mesenchymal stem cells (MSC act as trophic mediators and are successful in activating biomaterials. Here biodegradable sutures were filled with adipose-derived mesenchymal stem cells (ASC to provide a pro-regenerative environment at the injured site. Results showed that after filling, ASCs attach to the suture material, distribute equally throughout the filaments, and remain viable in the suture. Among a broad panel of cytokines, cell-filled sutures constantly release vascular endothelial growth factor to supernatants. Such conditioned media was evaluated in an in vitro wound healing assay and showed a significant decrease in the open wound area compared to controls. After suturing in an ex vivo wound model, cells remained in the suture and maintained their metabolic activity. Furthermore, cell-filled sutures can be cryopreserved without losing their viability. This study presents an innovative approach to equip surgical sutures with pro-regenerative features and allows the treatment and fixation of wounds in one step, therefore representing a promising tool to promote wound healing after injury.

  18. An innovative method to evaluate the suture compliance in sealing the surgical wound lips

    Directory of Open Access Journals (Sweden)

    Farid Saleh, Beniamino Palmieri, Danielle Lodi, Khalid Al-Sebeih

    2008-01-01

    Full Text Available Background and aim: The increasing number of surgical procedures performed with local anesthesia, followed by immediate patient discharge from the hospital, emphasizes the need for a tight waterproof suture that is capable of maintaining its tensile strength in the postoperative phase when the wound tumescence, edema due to the anesthetic drug, and surgical trauma disappear. Moreover, the issue of having an accurate surgical wound closure is very relevant in vivo in order to prevent hemorrhage and exogenous microbial infections. This study aimed at designing a new a lab technique that could be used for evaluating the best surgical material. Using such a technique, we compared the wound-lip-sealing properties of three commonly-used suture threads, namely polyurethane, polypropylene, and polyamide. Materials and methods: The mechanical properties of same-size suture threads made from polyurethane, polypropylene, and polyamide, were compared in order to define the one that possess the best elastic properties by being able to counteract the tension-relaxation process in the first 12 hours following surgery. The tension holding capacity of the suture materials was measured in both in vivo and in vitro experiments. The surface area of the scar associated with the three different suture threads was measured and compared, and the permeability of the three different suture threads was assessed at 0 minute, 2 minute, 4 minute, 6 minute, and 8 minute- interval. Results: Results showed that polyurethane suture threads had significantly (P < 0.05 better tensile strength, elongation endurance before breakage, and better elasticity coefficient as compared to polypropylene and polyamide suture threads. Moreover, polyurethane suture threads were significantly (P < 0.05 more impermeable as compared to the other two suture thread types (polypropylene and polyamide. This impermeability was also associated with a tighter wound-lip-sealing ability, and with

  19. EFFECTS OF DIFFERENT SUTURE MATERIALS ON TISSUE HEALING

    Directory of Open Access Journals (Sweden)

    Fırat SELVİ

    2016-01-01

    Full Text Available Purpose: The purpose of this study was to investigate the healing differences in between four different widely used suture materials in the oral surgery practice, including silk (Perma- Hand; Ethicon, INC., Somerville, NJ, USA, polypropylene (Prolene; Ethicon, INC., Somerville, NJ, USA, coated polyglactin 910 (Ethicon, INC., Somerville, NJ, USA. and polyglecaprone 25 (Ethicon, INC., Somerville, NJ, USA . Materials and Methods: 20 male rats were randomly allocated into two groups depending on their sacrification days (post-operative 1st and the 7th days. Four longitudinal incision wounds, each 1cm in size, were created on the dorsum of each animal which were then primarily closed with four different types of sutures. Results: The effects of these suture materials on soft tissue healing were compared histopathologically, by means of density of the cells, necrosis, fibrosis, foreign body reaction, the presence of cells of acute and chronic infection. No statistically significant difference was observed between the groups regarding the density of the cells, necrosis, fibrosis, foreign body reaction, and the presence of the cells of acute & chronic infections. Of note, propylene showed slightly less tissue reaction among the other materials. Conclusion: The results of our study showed that there is no only one ideal suture material for surgical practice. The factors related to the patient, the type of the surgery and the quality of the tissue are important to decide an appropriate suture material.

  20. The role of antimicrobial sutures in preventing surgical site infection.

    Science.gov (United States)

    Leaper, D; Wilson, P; Assadian, O; Edmiston, C; Kiernan, M; Miller, A; Bond-Smith, G; Yap, J

    2017-07-01

    INTRODUCTION Healthcare associated infections (HCAIs) are falling following widespread and enforced introduction of guidelines, particularly those that have addressed antibiotic resistant pathogens such as methicillin resistant Staphylococcus aureus or emergent pathogens such as Clostridium difficile, but no such decline has been seen in the incidence of surgical site infection (SSI), either in the UK, the EU or the US. SSI is one of the HCAIs, which are all avoidable complications of a surgical patient's pathway through both nosocomial and community care. METHODS This report is based on a meeting held at The Royal College of Surgeons of England on 21 July 2016. Using PubMed, members of the panel reviewed the current use of antiseptics and antimicrobial sutures in their specialties to prevent SSI. FINDINGS The group agreed that wider use of antiseptics in surgical practice may help in reducing reliance on antibiotics in infection prevention and control, especially in the perioperative period of open elective colorectal, hepatobiliary and cardiac operative procedures. The wider use of antiseptics includes preoperative showering, promotion of hand hygiene, (including the appropriate use of surgical gloves), preoperative skin preparation (including management of hair removal), antimicrobial sutures and the management of dehisced surgical wounds after infection. The meeting placed emphasis on the level I evidence that supports the use of antimicrobial sutures, particularly in surgical procedures after which the SSI rate is high (colorectal and hepatobiliary surgery) or when a SSI can be life threatening even when the rate of SSI is low (cardiac surgery).

  1. Bacterial adhesion to suture material in a contaminated wound model: Comparison of monofilament, braided, and barbed sutures.

    Science.gov (United States)

    Dhom, Jonas; Bloes, Dominik A; Peschel, Andreas; Hofmann, Ulf Krister

    2016-05-21

    Contaminated suture material plays an important role in the physiopathology of surgical site infections. Recently, suture material has been developed characterized by barbs projecting from a monofilament base. Claimed advantages for barbed sutures are a shortened wound closure time and reduced maximum wound tension. It has also been suggested that these sutures would be advantageous microbiologically. The aim of this study was to test the microbiological characteristics of the barbed Quill in comparison to the monofilament Ethilon II and the braided sutures Vicryl and triclosan-coated Vicryl Plus. In our study, sutures were cultivated on color-change agar with Staphylococcus aureus, Staphylococcus epidermidis, Enterococcus faecium, Escherichia coli, and Pseudomonas aeruginosa and the halo size was measured. In a second study arm with longer cultivation bacterial growth was followed by antibiotic treatment. Ethilon II and Quill showed good comparable results, whereas large halos were found around Vicryl. Vicryl Plus results depended on triclosan sensitivity. After longer bacterial cultivation and antibiotic treatment, halos were up to 3.6 times smaller on Quill than on Vicryl (P <.001), but 1.4 times larger than on Ethilon II (P <.001) regarding S. aureus. Confocal microscopy analysis showed bacterial colonization between the braided filaments on Vicryl and beneath the barbs on Quill. From a microbiological perspective, barbed sutures can be recommended in aseptic surgery, but should only be used carefully in septic surgery. This article is protected by copyright. All rights reserved.

  2. Performance Assessment of Suture Type in Juvenile Chinook Salmon Surgically Implanted with Acoustic Transmitters

    Energy Technology Data Exchange (ETDEWEB)

    Deters, Katherine A.; Brown, Richard S.; Carter, Kathleen M.; Boyd, James W.

    2009-02-27

    The objective of this study was to determine the best overall suture material to close incisions from the surgical implantation of Juvenile Salmon Acoustic Telemetry System (JSATS) acoustic microtransmitters in subyearling Chinook salmon Oncorhynchus tshawytscha. The effects of seven suture materials, four surgeons, and two water temperatures on suture retention, incision openness, tag retention, tissue inflammation, and tissue ulceration were quantified. The laboratory study, conducted by researchers at the Pacific Northwest National Laboratory, supports a larger effort under way for the U.S. Army Corps of Engineers, Portland District, aimed at determining the suitability of acoustic telemetry for estimating short- and longer-term (30-60 days) juvenile-salmonid survival at Columbia and Snake River dams and through the lower Columbia River.

  3. Long-term active antimicrobial coatings for surgical sutures based on silver nanoparticles and hyperbranched polylysine.

    Science.gov (United States)

    Ho, Chau Hon; Odermatt, Erich K; Berndt, Ingo; Tiller, Joerg C

    2013-01-01

    The goal of this study was to develop a long-term active antimicrobial coating for surgical sutures. To this end, two water-insoluble polymeric nanocontainers based on hyperbranched polylysine (HPL), hydrophobically modified by either using glycidyl hexadecyl ether, or a mixture of stearoyl/palmitoyl chloride, were synthesized. Highly stabilized silver nanoparticles (AgNPs, 2-5 nm in size) were generated by dissolving silver nitrate in the modified HPL solutions in toluene followed by reduction with L-ascorbic acid. Poly(glycolic acid)-based surgical sutures were dip-coated with the two different polymeric silver nanocomposites. The coated sutures showed high efficacies of more than 99.5% reduction of adhesion of living Staphylococcus aureus cells onto the surface compared to the uncoated specimen. Silver release experiments were performed on the HPL-AgNP modified sutures by washing them in phosphate buffered saline for a period of 30 days. These coatings showed a constant release of silver ions over more than 30 days. After this period of washing, the sutures retained their high efficacies against bacterial adhesion. Cytotoxicity tests using L929 mouse fibroblast cells showed that the materials are basically non-cytotoxic.

  4. A clinical study on the influence of suturing material on oral wound healing

    Directory of Open Access Journals (Sweden)

    Gazivoda Dragan

    2015-01-01

    Full Text Available Background/Aim. Suture materials play an important role in healing, enabling reconstruction and reassembly of tissue separated by the surgical procedure or trauma, and at the same time facilitating and promoting healing and hemostasis. Suture materials are used daily in oral surgery, and are considered to be substances most commonly implanted in human body. The aim of this clinical study was to examine the speed of wound healing and complications incidence, after the use of three different absorbable synthetic suture materials in oral surgery (catgut, Dexon and Vicryl rapide, and to ascertain which one is the most suitable for oral surgery. Methods. The study was conducted on 96 patients undergoing root resection or surgical extraction of third molars. Each of the suture materials (catgut, Dexon and Vicryl rapide was used for 8 root resections and 8 surgical third molar extractions in the maxilla, as well as in the mandible (a total of 32 surgical interventions for each suture material. Results. The faster wound healing was obtained with Vicryl rapide compared to other two suturing material tested. There was no significant difference regarding the presence of local reaction in all the three groups of patients on the 21st postoperative day. Conclusion. The results of our clinical study point out that Vycrilrapid contributes more than catgut or Dexon to faster healing of human wounds, with fewer incidences of wound dehiscence and milder local reactions.

  5. 21 CFR 878.4494 - Absorbable poly(hydroxybutyrate) surgical suture produced by recombinant DNA technology.

    Science.gov (United States)

    2010-04-01

    ... produced by recombinant DNA technology. 878.4494 Section 878.4494 Food and Drugs FOOD AND DRUG... recombinant DNA technology. (a) Identification. An absorbable poly(hydroxybutyrate) surgical suture is an...) Surgical Suture Produced by Recombinant DNA Technology.” For the availability of this guidance document...

  6. ABDOMINAL CLOSURE WITH ANTI BACTERIAL COATED SUTURE MATERIALS AND ITS RELATION TO THE INCIDENCE OF POST OPERATIVE SUPERFICIAL SURGICAL SITE INFECTION RATES

    OpenAIRE

    Josephine Pudumai Selvi; Celine Foustina Mary; Karthikeyan Rajashekar

    2017-01-01

    BACKGROUND Surgical site infection (SSI) is an immense burden on healthcare resources even in the modern era of immaculate sterilization approaches and highly effective antibiotics. An estimated 234 million various surgical procedures, involving skin incisions requiring various types of wound closure techniques, are performed in the world, with the majority resulting in a wound healing by primary intention. Triclosan (5-chloro-2-(2, 4-dichlorophenoxy) phenol) is a broad-spectrum b...

  7. Flexor Tenorrhaphy Using Absorbable Suture Materials

    Directory of Open Access Journals (Sweden)

    Hyung Joo Kang

    2012-07-01

    Full Text Available Background Nonabsorbable sutures are favorable for repairing flexor tendons. However,absorbable sutures have performed favorably in an animal model.Methods Two-strand sutures using the interlocking modified Kessler method with polydioxanoneabsorbable sutures 4-0 were used to repair completely ruptured flexor tendons in 55 fingersfrom 41 consecutive patients. The medical records of average 42 follow up weeks were analyzedretrospectively. The data analyzed using the chi-squared test, and Fisher’s exact test was used forpostoperative complications. The results were compared with those of other studies.Results Among the index, middle, ring, and little fingers were injured in 9, 17, 16, and13 fingers, respectively. The injury levels varied from zone 1 to 5. Of the 55 digits in ourstudy, there were 26 (47% isolated flexor digitorum profundus (FDP injuries and 29 (53%combined FDP and with flexor digitorum superficialis injuries. Pulley repair was also conducted.Concomitant injuries of blood vessels and nerves were found in 17 patients (23 fingers; nerveinjuries occurred in 5 patients (10 fingers. Two patients had ruptures (3.6%, and one patienthad two adhesions (3.6%. Using the original Strickland criteria, all the patients were assessedto be excellent or good. Also, fibrosis and long-term foreign body tissue reactions such as stitchgranuloma were less likely occurred in our study. Compared to the Cullen’s report that usednonabsorbable sutures, there was no significant difference in the rupture or adhesion rates.Conclusions Therefore, this study suggests that appropriate absorbable core sutures can beused safely for flexor tendon repairs.

  8. In vitro evaluation of novel antimicrobial coatings for surgical sutures using octenidine.

    Science.gov (United States)

    Obermeier, A; Schneider, J; Föhr, P; Wehner, S; Kühn, K-D; Stemberger, A; Schieker, M; Burgkart, R

    2015-09-24

    Sutures colonized by bacteria represent a challenge in surgery due to their potential to cause surgical site infections. In order to reduce these type of infections antimicrobially coated surgical sutures are currently under development. In this study, we investigated the antimicrobial drug octenidine as a coating agent for surgical sutures. To achieve high antimicrobial efficacy and required biocompatibility for medical devices, we focused on optimizing octenidine coatings based on fatty acids. For this purpose, antimicrobial sutures were prepared with either octenidine-laurate or octenidine-palmitate at 11, 22, and 33 μg/cm drug concentration normalized per length of sutures. Octenidine containing sutures were compared to the commercial triclosan-coated suture Vicryl® Plus. The release of octenidine into aqueous solution was analyzed and long-term antimicrobial efficacy was assessed via agar diffusion tests using Staphylococcus aureus. For determining biocompatibility, cytotoxicity assays (WST-1) were performed using L-929 mouse fibroblasts. In a 7 days elution experiment, octenidine-palmitate coated sutures demonstrated much slower drug release (11 μg/cm: 7%; 22 μg/cm: 5%; 33 μg/cm: 33%) than octenidine-laurate sutures (11 μg/cm: 82%; 22 μg/cm: 88%; 33 μg/cm: 87%). Furthermore sutures at 11 μg/cm drug content were associated with acceptable cytotoxicity according to ISO 10993-5 standard and showed, similar to Vicryl® Plus, relevant efficacy to inhibit surrounding bacterial growth for up to 9 days. Octenidine coated sutures with a concentration of 11 μg/cm revealed high antimicrobial efficacy and biocompatibility. Due to their delayed release, palmitate carriers should be preferred. Such coatings are candidates for clinical testing in regard to their safety and efficacy.

  9. VEGF-releasing suture material for enhancement of vascularization: development, in vitro and in vivo study.

    Science.gov (United States)

    Bigalke, Christian; Luderer, Frank; Wulf, Katharina; Storm, Thilo; Löbler, Marian; Arbeiter, Daniela; Rau, Bettina M; Nizze, Horst; Vollmar, Brigitte; Schmitz, Klaus-Peter; Klar, Ernst; Sternberg, Katrin

    2014-12-01

    As it has been demonstrated that bioactive substances can be delivered locally using coated surgical suture materials, the authors developed a vascular endothelial growth factor (VEGF)-releasing suture material that should promote vascularization and potentially wound healing. In this context, the study focused on the characterization of the developed suture material and the verification of its biological activity, as well as establishing a coating process that allows reproducible and stable coating of a commercially available polydioxanone suture material with poly(l-lactide) (PLLA) and 0.1μg and 1.0μg VEGF. The in vitro VEGF release kinetics was studied using a Sandwich ELISA. The biological activity of the released VEGF was investigated in vitro using human umbilical vein endothelial cells. The potential of the VEGF-releasing suture material was also studied in vivo 5days after implantation in the hind limb of Wistar rats, when the histological findings were analyzed. The essential results, enhanced cell viability in vitro as well as significantly increased vascularization in vivo, were achieved using PLLA/1.0μg VEGF-coated suture material. Furthermore, ELISA measurements revealed a high reproducibility of the VEGF release behavior. Based on the results achieved regarding the dose-effect relationship of VEGF, the stability during its processing and the release behavior, it can be predicted that a bioactive suture material would be successful in later in vivo studies. Therefore, this knowledge could be the basis for future studies, where bioactive substances with different modes of action are combined for targeted, overall enhancement of wound healing. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  10. Entrapment of Common Peroneal Nerve by Surgical Suture following Distal Biceps Femoris Tendon Repair

    Directory of Open Access Journals (Sweden)

    Aki Fukuda

    2016-01-01

    Full Text Available We describe entrapment of the common peroneal nerve by a suture after surgical repair of the distal biceps femoris tendon. Complete rupture of the distal biceps femoris tendon of a 16-year-old male athlete was surgically repaired. Postoperative common peroneal nerve palsy was evident, but conservative treatment did not cause any neurological improvement. Reexploration revealed that the common peroneal nerve was entrapped by the surgical suture. Complete removal of the suture and external neurolysis significantly improved the palsy. The common peroneal nerve is prone to damage as a result of its close proximity to the biceps femoris tendon and it should be identified during surgical repair of a ruptured distal biceps femoris tendon.

  11. Absorbable versus silk sutures for surgical treatment of trachomatous trichiasis in Ethiopia: a randomised controlled trial.

    Directory of Open Access Journals (Sweden)

    Saul N Rajak

    2011-12-01

    Full Text Available Trachoma causes blindness through an anatomical abnormality called trichiasis (lashes touching the eye. Trichiasis can recur after corrective surgery. We tested the hypothesis that using absorbable sutures instead of silk sutures might reduce the risk of recurrent disease among patients with major trichiasis in a randomised trial.1,300 individuals with major trichiasis from rural villages in the Amhara Region of Ethiopia were recruited and assigned (1:1 by computer-generated randomisation sequence to receive trichiasis surgery using either an absorbable suture (polyglactin-910 or silk sutures (removed at 7-10 days in an otherwise identical surgical technique. Participants were examined every 6 months for 2 years by clinicians masked to allocation. The primary outcome measure was recurrent trichiasis (≥one lash touching the eye at 1 year. There was no difference in prevalence of recurrent trichiasis at 1 year (114 [18.2%] in the absorbable suture group versus 120 [19.7%] in the silk suture group; odds ratio = 0.90, 95% CI 0.68-1.20. The two groups also did not differ in terms of corneal opacification, visual acuity, conjunctival inflammation, and surgical complications.There was no evidence that use of absorbable polyglactin-910 sutures was associated with a lower prevalence of trichiasis recurrence at 1 year postsurgery than silk sutures. However, from a programmatic perspective, polyglactin-910 offers the major advantage that patients do not have to be seen soon after surgery for suture removal. The postoperative review after surgery using absorbable polyglactin-910 sutures can be delayed for 3-6 months, which might allow us to better determine whether a patient needs additional surgery.ClinicalTrials.gov NCT00522860.

  12. Surgical treatment of traumatic eventration with polyester button and polypropylene mesh to strengthen the suture technique in equine

    OpenAIRE

    Orlandini, Carla Faria; Steiner, Denis; Boscarato, André Giarola; Gimenes, Gabriel Coelho; Alberton, Luiz Romulo

    2016-01-01

    Background Defects in the abdominal wall of horses have high relapse rate. This is mainly in lateral eventrations and hernias caused by trauma from kicks of other horses or installation structures. The eventration region normally becomes swollen and there may be complications due to intestinal loop incarceration. The surgical treatment, consisting of reconstruction of the abdominal wall, frequently require biological or synthetic materials for the reinforcement of the suture line and tension ...

  13. Stress-Softening and Residual Strain Effects in Suture Materials

    Directory of Open Access Journals (Sweden)

    Alex Elías-Zúñiga

    2013-01-01

    Full Text Available This work focuses on the experimental characterization of suture material samples of MonoPlus, Monosyn, polyglycolic acid, polydioxanone 2–0, polydioxanone 4–0, poly(glycolide-co-epsilon-caprolactone, nylon, and polypropylene when subjected to cyclic loading and unloading conditions. It is found that all tested suture materials exhibit stress-softening and residual strain effects related to the microstructural material damage upon deformation from the natural, undistorted state of the virgin suture material. To predict experimental observations, a new constitutive material model that takes into account stress-softening and residual strain effects is developed. The basis of this model is the inclusion of a phenomenological nonmonotonous softening function that depends on the strain intensity between loading and unloading cycles. The theory is illustrated by modifying the non-Gaussian average-stretch, full-network model to capture stress-softening and residual strains by using pseudoelasticity concepts. It is shown that results obtained from theoretical simulations compare well with suture material experimental data.

  14. Comparison of suture materials for subcuticular skin closure at cesarean delivery.

    Science.gov (United States)

    Tuuli, Methodius G; Stout, Molly J; Martin, Shannon; Rampersad, Roxane M; Cahill, Alison G; Macones, George A

    2016-10-01

    Subcuticular skin closure with suture after cesarean has been shown to result in lower rates of wound complications than with staple closure. However, the optimal choice of suture material for subcuticular skin closure is unclear. Vicryl (a braided multifilament synthetic suture; Ethicon, Somerville, NJ) and Monocryl (a monofilament synthetic suture; Ethicon) are the commonly used suture materials for subcuticular closure of transverse skin incisions after cesarean in the United States. Whereas in vitro and animal studies suggest multifilament suture materials may be associated with a higher risk of wound infection than monofilament sutures, clinical data on their relative effectiveness are limited. We sought to test the hypothesis that Vicryl is associated with a higher rate of wound complications than Monocryl. This is a secondary analysis of data from a randomized trial in which pregnant women undergoing scheduled or unscheduled cesareans were randomly assigned to preoperative skin preparation with either chlorhexidine-alcohol or iodine-alcohol. Women with low transverse skin incisions who were closed with either 4-0 Monocryl or 4-0 Vicryl were included in this analysis. Choice of suture material was at the discretion of the operating physician. The primary outcome was superficial or deep surgical site infection within 30 days after cesarean. Secondary outcomes were other wound complications. Outcomes were compared between the 2 groups using univariable and multivariable statistics. Of 1082 patients who had follow-up after discharge in the primary trial, 871 had subcuticular suture: 180 with 4-0 Vicryl and 691 with 4-0 Monocryl. Skin closure with Vicryl or Monocryl did not significantly differ between women allocated to chlorhexidine-alcohol or iodine-alcohol (51.1% vs 49.4%, P = .67). There was no significant difference in the risk of surgical site infection in women closed with Vicryl compared with Monocryl (11 [6.1%] vs 35 [5.1%]; P = .58; adjusted odds

  15. Comparison of Subcuticular Suture Materials in Cesarean Skin Closure

    Directory of Open Access Journals (Sweden)

    Pınar Solmaz Hasdemir

    2015-01-01

    Full Text Available Aim. Comparison of the rate of wound complications, pain, and patient satisfaction based on used subcuticular suture material. Methods. A total of 250 consecutive women undergoing primary and repeat cesarean section with low transverse incision were prospectively included. The primary outcome was wound complication rate including infection, dehiscence, hematoma, and hypertrophic scar formation within a 6-week period after operation. Secondary outcomes were skin closure time, the need for use of additional analgesic agent, pain score on numeric rating scale, cosmetic score, and patient scar satisfaction scale. Results. Absorbable polyglactin was used in 108 patients and nonabsorbable polypropylene was used in 142 patients. Wound complication rates were similar in primary and repeat cesarean groups based on the type of suture material. Skin closure time is longer in nonabsorbable suture material group in both primary and repeat cesarean groups. There was no difference between groups in terms of postoperative pain, need for additional analgesic use, late phase pain, and itching at the scar. Although the cosmetic results tended to be better in the nonabsorbable group in primary surgery patients, there was no significant difference in the visual satisfaction of the patients. Conclusions. Absorbable and nonabsorbable suture materials are comparable in cesarean section operation skin closure.

  16. Antibacterial-Coated Suture in Reducing Surgical Site Infection in Breast Surgery: A Prospective Study

    Directory of Open Access Journals (Sweden)

    Enora Laas

    2012-01-01

    Full Text Available Background. To reduce the incidence of microbial colonization of suture material, Triclosan- (TC-coated suture materials have been developed. The aim of this study was to assess the incidence of suture-related complications (SRC in breast surgery with and without the use of TC-coated sutures. Methods. We performed a study on two consecutive periods: 92 patients underwent breast surgery with conventional sutures (Group 1 and 98 with TC-coated sutures (Group 2. We performed subgroups analyses and developed a model to predict SRC in Group 1 and tested its clinical efficacy in Group 2 using a nomogram-based approach. Results. The SRC rates were 13% in Group 1 and 8% in Group 2. We found that some subgroups may benefit from TC-coated sutures. The discrimination obtained from a logistic regression model developed in Group 1 and based on multifocality, age and axillary lymphadenectomy was 0.88 (95% CI 0.77–0.95 (. There was a significant difference in Group 2 between predicted probabilities and observed percentages (. The predicted and observed proportions of complications in the high-risk group were 38% and 13%, respectively. Conclusion. This study used individual predictions of SRC and showed that using TC-coated suture may prevent SRC. This was particularly significant in high-risk patients.

  17. Cosmetic outcome and surgical site infection rates of antibacterial absorbable (Polyglactin 910) suture compared to Chinese silk suture in breast cancer surgery: a randomized pilot research

    Institute of Scientific and Technical Information of China (English)

    ZHANG Zhong-tao; Jessica Shen; Martin Weisberg; ZHANG Hong-wei; FANG Xue-dong; WANG Li-ming; LI Xiao-xi; LI Ya-fen; SUN Xiao-wei; Judith Carver; Dorella Simpkins

    2011-01-01

    Background The primary objective of this multicenter post-market study was to compare the cosmetic outcome of triclosan-coated VICRYL* Plus sutures with Chinese silk sutures for skin closure of modified radical mastectomy. A secondary objective was to assess the incidence of surgical site infection (SSI).Methods Patients undergoing modified radical mastectomy were randomly assigned to coated VICRYL* Plus antibacterial (Polyglactin 910) suture or Chinese silk suture. Cosmetic outcomes were evaluated postoperatively at days 12 (±2) and 30 (±5), and the evidence of SSI was assessed at days 3, 5, 7, 12 (±2), 30 (±5), and 90 (±7). Cosmetic outcomes were independently assessed via visual analogue scale (VAS) score evaluations of blinded incision photographs (primary endpoint) and surgeon-assessed modified Hollander Scale (mHCS) scores (secondary endpoint).SSI assessments used both CDC criteria and ASEPSIS scores.Results Six Chinese hospitals randomized 101 women undergoing modified radical mastectomy to closure with coated VICRYL* Plus suture (n=51) or Chinese silk suture (n=50). Mean VAS cosmetic outcome scores for antibacterial suture (67.2) were better than for Chinese silk (45.4) at day 30 (P<0.0001)). Mean mHCS cosmetic outcome total scores, were also higher for antibacterial suture (5.7) than for Chinese silk (5.0) at day 30 (P=0.002).Conclusions Patients using coated VICRYL* Plus suture had significantly better cosmetic outcomes than those with Chinese silk sutures. Patients using coated VICRYL* Plus suture had a lower SSI incidence compared to the Chinese silk sutures, although the difference did not reach statistical significance. (ClinicalTrials.gov NCT 00768222)

  18. Subtotal cranial vault remodelling in anterior sagittal suture closure: impact of age on surgical outcome

    NARCIS (Netherlands)

    Engel, M.; Hoffmann, J.; Muhling, J.; Castrillon-Oberndorfer, G.; Seeberger, R.; Freudlsperger, C.

    2012-01-01

    Isolated fusion of the sagittal suture is usually treated before 1 year of age, but some patients present at a later age. The aim of this study was to evaluate the impact of children's age on the surgical outcome. The authors investigated 46 patients with isolated nonsyndromic sagittal craniosynosto

  19. 21 CFR 878.4830 - Absorbable surgical gut suture.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4830 Absorbable...) or the submucosal fibrous tissue of sheep (ovine) intestine, and is intended for use in soft...

  20. Biocompatibility and biomechanical analysis of elastic TPU threads as new suture material.

    Science.gov (United States)

    Vogels, Ruben R M; Lambertz, Andreas; Schuster, Philipp; Jockenhoevel, Stefan; Bouvy, Nicole D; Disselhorst-Klug, Catherine; Neumann, Ulf P; Klinge, Uwe; Klink, Christian D

    2017-01-01

    High suture tension is one of the causes for many wound-healing problems. Constriction of tissue within the suture loops of nonelastic sutures can lead to cutting of the suture through tissues and necrosis of the tissue within these loops. The use of elastic materials in new suture types could give the material the ability to adapt tension to the tissue requirements and subsequently lead to more vital tissue within its loops. We evaluated the foreign body host response, as indicator of biocompatibility, to a new thermoplastic poly(carbonate) urethane (TPU) synthetic suture material in a rat model compared with standard nonelastic polypropylene (PP) sutures. Tissue samples were collected at 7 and 21 days, and host response was evaluated. Subsequently, suture tension curves of the new elastic sutures for the first 30 min after knotting were recorded in a pig model. The new TPU sutures showed an improved foreign body response when compared with that of PP, with a reduction in the amount of macrophages surrounding the material. Tension experiments showed a superior tension curve for TPU sutures, with a major reduction in peak suture tension when compared with that of standard PP sutures, while still retaining adequate tension after 30 min. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 99-106, 2017.

  1. Tension of knotted surgical sutures shows tissue specific rapid loss in a rodent model

    Directory of Open Access Journals (Sweden)

    Klink Christian D

    2011-12-01

    Full Text Available Abstract Background Every surgical suture compresses the enclosed tissue with a tension that depends from the knotting force and the resistance of the tissue. The aim of this study was to identify the dynamic change of applied suture tension with regard to the tissue specific cutting reaction. Methods In rabbits we placed single polypropylene sutures (3/0 in skin, muscle, liver, stomach and small intestine. Six measurements for each single organ were determined by tension sensors for 60 minutes. We collected tissue specimens to analyse the connective tissue stability by measuring the collagen/protein content. Results We identified three phases in the process of suture loosening. The initial rapid loss of the first phase lasts only one minute. It can be regarded as cutting through damage of the tissue. The percentage of lost tension is closely related to the collagen content of the tissue (r = -0.424; p = 0.016. The second phase is characterized by a slower decrease of suture tension, reflecting a tissue specific plastic deformation. Phase 3 is characterized by a plateau representing the remaining structural stability of the tissue. The ratio of remaining tension to initial tension of phase 1 is closely related to the collagen content of the tissue (r = 0.392; p = 0.026. Conclusions Knotted non-elastic monofilament sutures rapidly loose tension. The initial phase of high tension may be narrowed by reduction of the surgeons' initial force of the sutures' elasticity to those of the tissue. Further studies have to confirm, whether reduced tissue compression and less local damage permits improved wound healing.

  2. Evaluation of opening pattern and bone neoformation at median palatal suture area in patients submitted to surgically assisted rapid maxillary expansion (SARME through cone beam computed tomography

    Directory of Open Access Journals (Sweden)

    Daniel Gomes SALGUEIRO

    2015-08-01

    Full Text Available AbstractSurgically assisted rapid maxillary expansion (SARME is the treatment of choice to adult patients even with severe transversal maxillary discrepancies. However, the adequate retention period to achieve the bone remodeling, thus assuring treatment stability, is controversial.Objective To evaluate the opening pattern and bone neoformation process at the midpalatal suture in patients submitted to surgically assisted (SARME through cone beam computed tomography (CBCT.Material and Methods Fourteen patients were submitted to SARME through subtotal Le Fort I osteotomy. Both the opening pattern and the mean bone density at midpalatal suture area to evaluate bone formation were assessed pre- and post-operatively (15, 60 and 180 days through CBCT.Results Type I opening pattern (from anterior to posterior nasal spine occurred in 12 subjects while type II opening pattern (from anterior nasal spine to transverse palatine suture occurred in 2 individuals. The 180-day postoperative mean (PO 180 of bone density value was 49.9% of the preoperative mean (Pre value.Conclusions The opening pattern of midpalatal suture is more related to patients’ age (23.9 years in type I and 33.5 years in type II and surgical technique. It was not possible to observe complete bone formation at midpalatal suture area at the ending of the retention period studied (180 days.

  3. Efficacy of Murva (Sansevieria roxburghiana Schult. and Schult.f.) as a suture material in closure of incisions in third molar surgeries: A prospective study.

    Science.gov (United States)

    Lambade, Pravin; Thorat, Ashutosh

    2017-01-01

    Adequate closure of the surgical wound is one of the most important aspects of surgery; improper suturing techniques or improper suturing materials sometimes compromise the success of surgery. Many synthetic materials have replaced the natural materials, which were once used for suturing in the ancient era, and Murva is one of them. There are references of Murva (Sansevieria roxburghiana Schult. and Schult.f.) at various contexts of "Sushruta Samhita" where it has been used as a suture material. It is a xerophytic herbaceous plant occurring abundantly in the eastern coastal region of India. The aim of this study is to evaluate the efficacy of Murva fibers as a suturing material in closure of intraoral incision in third molar surgeries. Fifty incisions (Wards incision) placed for the surgical removal of mandibular third molar were sutured with Murva, and follow-up was carried out postoperatively on 1(st), 2(nd), 3(rd), and 7(th) day. Patients were evaluated for pain, swelling, bleeding, infection, wound dehiscence, local tissue irritation, and bacterial colonization. On various follow-ups, progressively significant and predictable healing was observed without any uneventful evidence. The use of Murva as a suture material proved to be effective in closure of intraoral incisions.

  4. The “excluding” suture technique for surgical closure of ventricular septal defects: A retrospective study comparing the standard technique

    Directory of Open Access Journals (Sweden)

    Roy Varghese

    2016-01-01

    Conclusion: Surgical closure of VSDs can be accomplished by placing sutures along the margins or away with comparable results. The incidence of CHB, however, seems to be less when the “excluding” technique is employed.

  5. Conduction Disorders in Continuous Versus Interrupted Suturing Technique in Ventricular Septal Defect Surgical Repair

    Directory of Open Access Journals (Sweden)

    Gholampour-Dehaki

    2016-01-01

    Full Text Available Background Ventricular septal defects (VSD is one of the most frequent congenital cardiac malformations and cardiac conduction disorders are still one of the serious postoperative complications in this surgery. Objectives This study aimed to compare the incidence of conduction disorders with the use of continuous compared to interrupted suturing techniques in VSD surgical repair. Patients and Methods Previously recorded data of 231 patients who underwent surgical closure of VSD between January 2009 and January 2012 at the Rajaie cardiovascular medical and research center were retrospectively reviewed. VSD surgical repair was performed using continues suturing technique in group A patients (n = 163, 70.6% and interrupted suturing technique in group B patients (n = 68, 29.4%. Results The most common concomitant congenital anomaly was Tetralogy of Fallot (27.3%. Twenty-four (10.4% patients had intraoperative cardiac arrhythmia, including 19 (8.2% transient and 5 (2.2 % permanent arrhythmia. During their ICU stay, ventricular arrhythmia and complete heart block were observed in 34 (14.7% and 5 patients (2.2%, respectively. At the time of the last follow-up, incomplete right bundle branch block (RBBB, complete RBBB, RBBB with left anterior hemi-block, and complete heart block were identified in 84 (36.4%, 42 (18.2%, 29 (12.6%, and 5 patients (2.2%, respectively. The results revealed that group A patients were most likely to have had cardiac arrhythmias during their ICU stay and at the time of last follow-up (P < 0.001, while the intraoperative incidence of cardiac arrhythmia during surgery was not statistically significant between the two groups (P = 0.06. Conclusions In the absence of any statistical differences in the other risk factors between the two groups, the difference in the incidence of conduction disorders can be attributed to the type of suturing used during the procedure.

  6. The potential of photoacoustic microscopy as a tool to characterize the in vivo degradation of surgical sutures.

    Science.gov (United States)

    Aguirre, Juan; Morales-Dalmau, Jordi; Funk, Lutz; Jara, Francesc; Turon, Pau; Durduran, Turgut

    2014-08-01

    The ex vivo and in vivo imaging, and quantitative characterization of the degradation of surgical sutures (∼500 μm diameter) up to ∼1cm depth is demonstrated using a custom dark-field photo-acoustic microscope (PAM). A practical algorithm is developed to accurately measure the suture diameter during the degradation process. The results from tissue simulating phantoms and mice are compared to ex vivo measurements with an optical microscope demonstrating that PAM has a great deal of potential to characterize the degradation process of surgical sutures. The implications of this work for industrial applications are discussed.

  7. Surgical staples compared with subcuticular suture for skin closure after cesarean delivery: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Sahar Assadi

    2016-03-01

    Full Text Available Background: Cesarean delivery is the most common surgical procedure and this prevalence is on the rise. Given these trends, cesarean wound complications, such as disruption or infection, remain an important cause of post-cesarean morbidity. Methods: We conducted a single-center randomized controlled trial that included women with viable pregnancies (≥24 weeks undergoing cesarean delivery at Motahary University Hospital, Urmia, Iran from April to November 2014. All cesarean types were included: scheduled or unscheduled and primary or repeat cesareans. Women were excluded for the following reasons: inability to obtain informed consent, immune compromising disease (e.g. AIDS, chronic steroid use, diabetic mellitus and BMI≥30. Of 266 women, 133 were randomized to staples and 133 women to suture group. Results: The mean±SD age of the staples group was 27.6±5.4 years and mean±SD age of suture was 28.7±5.9 years. Multiparity is the most frequent in both groups that by using Chi-square test, no significant differences were observed between the two groups (P=0.393. The most frequent indication for cesarean section in both groups was history of cesarean section in staple 40 cases (30.1% and suture 32 cases (24.1%. The survey was conducted using the Chi-square test was not significant (P=0.381. Pain at 6 weeks postoperatively was significantly less in the staple group (P=0.001. Operative time was longer with suture closure (4.68±0.67 versus 1.03±0.07 minute, P<0.001. The Vancouver scale score was significantly less in suture closure (6.6±0.8 versus 7.5±0.9, P=0.001. Wound disruption was significantly less in suture closure (3.8% versus 11.3%, P=0.017. Conclusion: The staple group had low pain and operation time but had a significant wound disruption and scar. The patients who have suffered a significant wound disruption were affected by age (P=0.022 and BMI (P=0.001 at compared those who were not affected by factors such as age or high BMI as

  8. Novel high efficient coatings for anti-microbial surgical sutures using chlorhexidine in fatty acid slow-release carrier systems.

    Directory of Open Access Journals (Sweden)

    Andreas Obermeier

    Full Text Available Sutures can cause challenging surgical site infections, due to capillary effects resulting in bacteria permeating wounds. Anti-microbial sutures may avoid these complications by inhibiting bacterial pathogens. Recently, first triclosan-resistances were reported and therefore alternative substances are becoming clinically relevant. As triclosan alternative chlorhexidine, the "gold standard" in oral antiseptics was used. The aim of the study was to optimize novel slow release chlorhexidine coatings based on fatty acids in surgical sutures, to reach a high anti-microbial efficacy and simultaneously high biocompatibility. Sutures were coated with chlorhexidine laurate and chlorhexidine palmitate solutions leading to 11, 22 or 33 µg/cm drug concentration per length. Drug release profiles were determined in aqueous elutions. Antibacterial efficacy against Staphylococcus aureus was assessed in agar diffusion tests. Biocompatibility was evaluated via established cytotoxicity assay (WST-1. A commercially triclosan-containing suture (Vicryl Plus, was used as anti-microbial reference. All coated sutures fulfilled European Pharmacopoeia required tensile strength and proved continuous slow drug release over 96 hours without complete wash out of the coated drug. High anti-microbial efficacy for up to 5 days was observed. Regarding biocompatibility, sutures using 11 µg/cm drug content displayed acceptable cytotoxic levels according to ISO 10993-5. The highest potential for human application were shown by the 11 µg/cm chlorhexidine coated sutures with palmitic acid. These novel coated sutures might be alternatives to already established anti-microbial sutures such as Vicryl Plus in case of triclosan-resistance. Chlorhexidine is already an established oral antiseptic, safety and efficacy should be proven for clinical applications in anti-microbial sutures.

  9. Evaluation of three suture techniques based on surgical wound assessment in Caprine

    Directory of Open Access Journals (Sweden)

    John Bayo Adeyanju

    2012-11-01

    Full Text Available Subcuticular, simple interrupted and ford interlocking suture patterns were used in closing skin incision at paralumbar fossa in fifteen apparently healthy male and female adult goats. The goats were randomly divided into three groups: A (Subcuticular; B(Ford interlocking and C(Simple interrupted. Clinical appearance of the surgical wound was scored twice post surgery at 18-24 hours and 10-14 days using swelling, erythema, dehiscence and discharge as the parameters. There were no statistical difference (P

  10. Effects of myrrh on the strength of suture materials: an in vitro study.

    Science.gov (United States)

    Alshehri, Mohammed A; Baskaradoss, Jagan Kumar; Geevarghese, Amrita; Ramakrishnaiah, Ravikumar; Tatakis, Dimitris N

    2015-01-01

    The present in vitro study sought to determine the effects of myrrh-containing solutions on common suture materials used in periodontal surgery. Three commonly used suture materials (silk, polyglactin 910, polytetrafluoroethylene) were immersed in four thermostatically controlled experimental media to simulate daily oral rinsing activity, namely -artificial saliva, normal saline solution with 0.2% Commiphora myrrh, full-concentration (100%) Commiphora myrrh oil, and a myrrh-containing commercial mouthwash. Tensile strength was measured at the end of each day using an Instron tensile testing machine. Silk sutures were susceptible to tensile strength loss when exposed to 0.2% myrrh solution once daily for 5 days. Myrrh-containing commercial mouthwash had no effect on tensile strength, but all three suture materials lost tensile strength when exposed to 100% myrrh oil. For patients that routinely use myrrh mouthwashes postoperatively, findings of this study suggested that silk sutures might not be the optimal material choice.

  11. Comparison of antibacterial-coated and non-coated suture material in intraoral surgery by isolation of adherent bacteria

    Directory of Open Access Journals (Sweden)

    Klaus Pelz

    2015-09-01

    In terms of the total number of oral bacteria, and especially oral pathogens, that adhered to suture material, no reduction was demonstrated for Vicryl Plus. The use of triclosan-coated suture material offers no advantage in intraoral surgery.

  12. Surgical tip: Repair of acute Achilles rupture with Krackow suture through a 1.5 cm medial wound.

    Science.gov (United States)

    Lui, T H

    2010-03-01

    Acute Achilles tendon ruptures is one of the commonest tendon injury of the foot and ankle. The management of this problem is still controversial. Treatment can be classified into non-surgical and surgical types. Surgical management can be subdivided into open repair, percutaneous with or without adjunct of arthroscopy. In compare with non-surgical management, surgical management will decrease the tendon re-rupture rate. However, the possible surgical complications including wound breakdown and sural nerve injury are still quite significant. Percutaneous repair technique has the advantage of less chance of wound breakdown, but the rate of tendon re-rupture is higher than that after open tendon repair, because the repair is usually weaker than that achieved in open repair. Lui have described an endoscopic assisted repair with the Krackow locking suture. However, the technique is complicated and six portal wounds are needed. A simpler way of applying the Krackow suture through the portal wound has been described for reattachment of Achilles tendon insertion after endoscopic calcaneoplasty. We describe a mini-open approach of Achilles tendon repair with the Krackow locking suture. By means of release of the medial edge of the investing fascia, the Achilles tendon can be mobilized easily and the Krackow locking suture can be applied through a 1.5cm medial wound. Hopefully, this can improve the strength of repair and maintaining the advantage of minimally invasive tendon repair.

  13. ADVANTAGES OF SURGICAL TREATMENT OF ACHILLES TENDON RUPTURE BY PERCUTANEOUS SUTURE AS OPPOSED TO NONSURGICAL TREATMENT

    Directory of Open Access Journals (Sweden)

    Goran Vidić

    2010-06-01

    Full Text Available The Achilles tendon is the strongest tendon in the body, and its rupture appears to be the most common injury of the tendomuscular apparatus. This type of injury is more frequent in sportsmen, especially those who play tennis, gymnastics, skiing, handball, football, basketball and athletics. Also, the ruptures are common in people who engage in sports activities for recreation. They appear more often in males, in proportion of 3:1. It appears reciprocally in 25- 30% of the cases. The rupture is easily diagnosed by means of clinical examination (Thompson's test and ultrasonography.The aim of the analysis was to point to the advantages of surgical treatment of a fresh Achilles tendon rupture as opposed to non-surgical treatment by plaster immobilization.The examination was performed on 35 patients, of which 16 (45,71% were treated operatively and 19 (54,29% were treated nonoperatively. The average age of the patients was 38.8 years, that is 37.1 for those treated operatively and 40.2 for those treated nonoperatively. Among the examinees, there were 29(82,86% men and 6 (17,14% women. The operative treatment method consisted of percutaneous suturing, whereas the nonoperative treatment involved the circular above the knee plaster immobilization. All operatively treated patients underwent the surgical treatment in the first 48 hours from the time when the injury had occured. Anesthesia was local and infiltrative.The obtained results showed that there were no unhealed ruptures or re-ruptures. In the group of patients who did not undergo the surgery, there was 1 re-rupture and 1 unhealed rupture, after which the surgical treatment had to be performed in both cases. In the group of operated patients there were no infections, however, 1 thromboembolism occured. Recovery of muscular strenght of the tendon and the realization of the full range of movement required less time in the operated patients. The ultrasonographic findings in the operated patients

  14. Systematic review of absorbable vs non-absorbable sutures used for the closure of surgical incisions

    Institute of Scientific and Technical Information of China (English)

    Muhammad; S; Sajid; Malcolm; R; Mc; Fall; Pauline; A; Whitehouse; Parv; S; Sains

    2014-01-01

    AIM: To report a systematic review of published randomized controlled trials(RCTs) investigating the role of absorbable suture(AS) against non-AS(NAS) used for the closure of surgical incisions.METHODS: RCTs investigating the use of AS vs NAS for the closure of surgical incisions were statistically analysed based upon the principles of meta-analysis and the summated outcomes were represented as OR.RESULTS: The systematic search of medical literature yielded 10 RCTs on 1354 patients. Prevalence of wound infection(OR = 0.97; 95%CI: 0.56, 1.69; Z = 0.11; P = 0.92) and operative morbidity(P = 0.45) was comparable in both groups. Nonetheless, the use of AS lead to lower risk of wound break-down(OR = 0.12; 95%CI: 0.04, 0.39; Z = 3.52; P < 0.0004).CONCLUSION: This meta-analysis of 10 RCTs demonstrates that the use of AS is similar to NAS for skin closure for surgical site infection and other operative morbidities. AS do not increase the risk of skin wound dehiscence,rather lead to a reduced risk of wound dehiscence compared to NAS.

  15. Comparison of seven different suture materials in the feline oral cavity.

    Science.gov (United States)

    DeNardo, G A; Brown, N O; Trenka-Benthin, S; Marretta, S M

    1996-01-01

    Seven different suture materials were implanted into the oral tissues of 12 cats. The sutures and surrounding tissues were retrieved en bloc from each of two cats on days one, three, seven, 14, 21, and 28 postimplantation. Tissue reaction and suture duration were evaluated by gross visual observation and histological examination. Chromic gut disappeared between days three and seven; polyglactin 910 disappeared between days 14 and 21; and polyglycolic acid disappeared as early as seven to 14 days. Polydioxanone still was intact at day 28 and is recommended as an absorbable material for procedures in which longer healing time is anticipated. All the nonabsorbable suture materials (i.e., polypropylene, stainless steel, and nylon) were intact at day 28 postimplantation. Visual inspection showed polypropylene to have the least tissue reaction.

  16. Association between Fellowship Training, Surgical Volume, and Laparoscopic Suturing Techniques among Members of the American Association of Gynecologic Laparoscopists

    Directory of Open Access Journals (Sweden)

    Emad Mikhail

    2016-01-01

    Full Text Available Study Objective. To compare surgical volume and techniques including laparoscopic suturing among members of the American Association of Gynecologic Laparoscopists (AAGL according to fellowship training status. Design. A web-based survey was designed using Qualtrics and sent to AAGL members. Results. Minimally invasive gynecologic surgery (FMIGS trained surgeons were more likely to perform more than 8 major conventional laparoscopic cases per month (63% versus 38%, P<0.001, OR [95% CI] = 2.78 [1.54–5.06] and were more likely to perform laparoscopic suturing during these cases (32% versus 16%, P<0.004, OR [95% CI] = 2.44 [1.25–4.71]. The non-fellowship trained (NFT surgeons in private practice were less likely to perform over 8 conventional laparoscopic cases (34% versus 51%, P=0.03, OR [95% CI] = 0.50 [0.25–0.99] and laparoscopic suturing during these cases (13% versus 27%, P=0.01, OR [95% CI] = 0.39 [0.17–0.92] compared to NFT surgeons in academic practice. Conclusion. The surgical volume and utilization of laparoscopic suturing of FMIGS trained surgeons are significantly increased compared to NFT surgeons. Academic practice setting had a positive impact on surgical volume of NFT surgeons but not on FMIGS trained surgeons.

  17. Association between Fellowship Training, Surgical Volume, and Laparoscopic Suturing Techniques among Members of the American Association of Gynecologic Laparoscopists.

    Science.gov (United States)

    Mikhail, Emad; Scott, Lauren; Miladinovic, Branko; Imudia, Anthony N; Hart, Stuart

    2016-01-01

    Study Objective. To compare surgical volume and techniques including laparoscopic suturing among members of the American Association of Gynecologic Laparoscopists (AAGL) according to fellowship training status. Design. A web-based survey was designed using Qualtrics and sent to AAGL members. Results. Minimally invasive gynecologic surgery (FMIGS) trained surgeons were more likely to perform more than 8 major conventional laparoscopic cases per month (63% versus 38%, P < 0.001, OR [95% CI] = 2.78 [1.54-5.06]) and were more likely to perform laparoscopic suturing during these cases (32% versus 16%, P < 0.004, OR [95% CI] = 2.44 [1.25-4.71]). The non-fellowship trained (NFT) surgeons in private practice were less likely to perform over 8 conventional laparoscopic cases (34% versus 51%, P = 0.03, OR [95% CI] = 0.50 [0.25-0.99]) and laparoscopic suturing during these cases (13% versus 27%, P = 0.01, OR [95% CI] = 0.39 [0.17-0.92]) compared to NFT surgeons in academic practice. Conclusion. The surgical volume and utilization of laparoscopic suturing of FMIGS trained surgeons are significantly increased compared to NFT surgeons. Academic practice setting had a positive impact on surgical volume of NFT surgeons but not on FMIGS trained surgeons.

  18. Influence of suturing material on wound healing: Experimental study in dogs

    Directory of Open Access Journals (Sweden)

    Gazivoda Dragan

    2015-01-01

    Full Text Available Background/Aim. The most common materials implanted in the human organism are suture materials that are classified on the basis of several criteria, usually the origin, structure, and properties. The properties of suture materials are related to its absorbability and non-absorbability. When using resorbable materials it is of great importance to determine whether its absorbability and tensile strength help wound healing in function of time. Sutures themselves can become a source of inflammation, that may reduce or compromise the potential of reparation and regeneration. The aim of this experimental study on dogs was to ascertain whether the absorption rate and the degree of local tissue reactions differ from information provided by the manufacturers, whether there are differences between the applied suture materials and which of the used suture materials have better effect on wound healing. Methods. Experimental testing of the selected suture materials basic characteristics was performed on 6 German Shepherd dogs, which, after induction of general anesthesia, were made 3 identical incisions each in all 4 quadrants (left and right side of the upper and lower jaws, so that 12 horizontal incisions were formed, 10 mm long, 20-25 mm distant from one another, on each animal. Randomly, incisions were stitched up in the following order, starting from back to front: catgut, Dexon®, Vicryl-Rapid®. The experiment was terminated by histopathological examination of tissue samples, taken on postoperative day 3, 7, 14 and 21 in order to identify the effect of healing and the degree of local reaction. Results. The obtained results suggest that catgut has the highest absorption rate, while Dexon® the lowest. Vicryl-Rapid® causes the lowest level of local reactions, while Dexon® the highest. Conclusion. There is no ideal suture material because various patient factors also influence the wound healing process.

  19. The influence of surgical correction on white matter microstructural integrity in rabbits with familial coronal suture craniosynostosis

    Science.gov (United States)

    Bonfield, Christopher M.; Foley, Lesley M.; Kundu, Shinjini; Fellows-Mayle, Wendy; Hitchens, T. Kevin; Rohde, Gustavo K.; Grandhi, Ramesh; Mooney, Mark P.

    2017-01-01

    OBJECT Craniosynostosis is a condition in which one or more of the calvarial sutures fuses prematurely. In addition to the cosmetic ramifications attributable to premature suture fusion, aberrations in neurophysiological parameters are seen, which may result in more significant damage. This work examines the microstructural integrity of white matter, using diffusion tensor imaging (DTI) in a homogeneous strain of rabbits with simple, familial coronal suture synostosis before and after surgical correction. METHODS After diagnosis, rabbits were assigned to different groups: wild-type (WT), rabbits with early-onset complete fusion of the coronal suture (BC), and rabbits that had undergone surgical correction with suturectomy (BC-SU) at 10 days of age. Fixed rabbit heads were imaged at 12,25, or 42 days of life using a 4.7-T, 40-cm bore Avance scanner with a 7.2-cm radiofrequency coil. For DTI, a 3D spin echo sequence was used with a diffusion gradient (b = 2000 sec/mm2) applied in 6 directions. RESULTS As age increased from 12 to 42 days, the DTI differences between WT and BC groups became more pronounced (p days and 100% accurate at 42 days). CONCLUSIONS Craniosynostosis results in characteristic changes of major white matter tracts, with differences becoming more apparent as the age of the rabbits increases. Early suturectomy (at 10 days of life) appears to mitigate these differences. PMID:25929965

  20. Pancreaticojejunostomy after pancreaticoduodenectomy: Suture material and incidence of post-operative pancreatic fistula.

    Science.gov (United States)

    Andrianello, Stefano; Pea, Antonio; Pulvirenti, Alessandra; Allegrini, Valentina; Marchegiani, Giovanni; Malleo, Giuseppe; Butturini, Giovanni; Salvia, Roberto; Bassi, Claudio

    2016-01-01

    Pancreatic fistula represents the most important complication in terms of clinical management and costs after pancreaticoduodenectomy. A lot of studies have investigated several techniques in order to reduce pancreatic fistula, but data on the effect of sutures material on pancreatic fistula are not available. The analysis investigated the role of suture material in influencing pancreatic fistula rate and severity. Results from 130 consecutive pancreaticoduodenectomy with pancreaticojejunostomy performed between March 2013 and September 2014 were prospectively collected and analyzed. In 65 cases pancreaticojejunostomy was performed with absorbable sutures, in the other 65 cases using non-absorbable sutures (polyester, silk and polybutester). Pancreaticojejunostomy with non-absorbable sutures had the same incidence of pancreatic fistula, but less severe and with less episodes of post-operative bleeding if compared with absorbable sutures. A sub-analysis was carried out comparing polydioxanone with polyester: the latter was associated with a lower pancreatic fistula rate (11.9% vs. 31.7%; p = 0,01) and less severe pancreatic anastomosis dehiscence (grade C - 0% vs. 30%; p = 0.05). Univariate and multivariate analysis confirmed that hard pancreatic texture, pancreatic ductal adenocarcinoma at final histology and the use of polyester for pancreaticojejunostomy were associated with a lower pancreatic fistula rate (p fistula with less severe clinical impact. Copyright © 2015 IAP and EPC. Published by Elsevier India Pvt Ltd. All rights reserved.

  1. Systematic review and meta-analysis of sutures coated with triclosan for the prevention of surgical site infection after elective colorectal surgery according to the PRISMA statement.

    Science.gov (United States)

    Sandini, Marta; Mattavelli, Ilaria; Nespoli, Luca; Uggeri, Fabio; Gianotti, Luca

    2016-08-01

    Several randomized clinical trials (RCTs) conducted to evaluate the effect of triclosan-coated suture on surgical site infection (SSI) yield to controversial results. The primary purpose of this systematic review and meta-analysis was to analyze the available RCTs, comparing the effect of triclosan-coated suture with uncoated suture on the incidence of SSI after elective colorectal operations. As secondary endpoint of the analysis, we considered length of hospital stay after surgery. We performed a systematic literature review through Medline, Embase, Pubmed, Scopus, Ovid, ISI Web of Science, and the Cochrane Controlled Trials Register searching for RCTs published from 1990 to 2015. To conduct these meta-analyses, we followed the guidelines and the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. Study inclusion criteria were as follows: parallel-group RCTs in adult populations reporting the closure of the abdominal wall after elective colorectal operation with triclosan-coated suture or noncoated suture, and reporting the outcomes considered in the meta-analysis. Six trials including 2168 patients (1102 treated and 1066 controls) provided data on SSIs. The overall rate was 11.7% (129/1102) in the triclosan group and 13.4% (143/1066) in the control group (odds ratio 0.81, 95% confidence interval [CI] 0.58-1.13, P = 0.220). Heterogeneity among studies was moderate (I = 44.9%). No evidence of publication bias was detectable. Five RCTs (1783 patients; 914 treated and 689 controls) described hospital length of stay with no significant effect (mean difference: -0.02, 95% CI -0.11 to -0.07, P = 0.668). The I test for heterogeneity was 0% (P = 0.836). Moderator analyses showed no significant differences were detected in analyses comparing the suture materials (polydioxanone vs polyglactin). In open-label trials, the odds ratio for SSI risk was 0.62 (95% CI 0.20-1.93, P = 0.413), 0.77 in single-blind (95% CI 0.31-1.95, P

  2. Post operation recurrence of inguinal hernia in children and its relation with suture material

    Directory of Open Access Journals (Sweden)

    Omid Amanollahi

    2011-09-01

    Full Text Available Background: Using non-absorbable suture in children hernia repair to decrease of recurrence is recommended in the most pediatric surgery centers. The aim of this study was to determine relationship between kind of suture material and rate of hernia recurrence. Methods: In this clinical trial 200 children (age 1-5 years with inguinal hernia who operated in Imam-Reza Hospital (kermanshah –Iran Between April 2007 until April 2008 enrolled into the study. Cases were selected by convenience sampling method and then randomly divided into two groups (100 cases per group and operated with absorbable (silk 3-0 and non-absorbable (vicryli 3-0 suture material. Following period was 12 months after operation and collected data analyzed by statistical software. Emergency operations were excluded from the study.Results: 83% of patients were boy and 17% were girl. %53 showed right side inguinal, 29% left side and %18 were bilateral hernia. After one year follow up only one case of recurrence was observed in each group.Conclusion: Our study confirmed that recurrence of inguinal hernia in children after surgery, is not related to kind of suture material (absorbability and we didn’t find any significant difference. Other factors than suture material may influence recurrence rate of hernia operation in children.

  3. Achilles tendon reattachment after surgical treatment of insertional tendinosis using the suture bridge technique: a case series.

    Science.gov (United States)

    Witt, Bryan L; Hyer, Christopher F

    2012-01-01

    Achilles tendinopathy is a clinical diagnosis characterized as a triad of symptoms including pain, swelling, and impaired performance of the diseased tendon. Achilles tendinopathy is divided into Achilles tendonitis and tendinosis based on histopathological examination. Achilles tendinosis is viewed microscopically as disorganized collagen, abnormal neovascularization, necrosis, and mucoid degeneration. Insertional Achilles tendinosis is a degenerative process of the tendon at the junction of the tendon and calcaneus. This disease is initially treated conservatively with activity modification, custom orthotic devices, heel lifts, and immobilization. After 3 to 6 months of conservative therapy has failed to alleviate symptoms, surgical management is indicated. Surgical management of insertional Achilles tendinosis includes Achilles tendon debridement, calcaneal exostosis ostectomy, and retrocalcaneal bursa excision. In this case series, we present 4 patients who underwent surgical management of insertional Achilles tendinosis with complete tendon detachment. All patients underwent reattachment of the Achilles tendon with the suture bridge technique. The Arthrex SutureBridge(®) (Arthrex, Inc., Naples, FL) device uses a series of 4 suture anchors and FiberWire(®) (Arthrex Inc.) to reattach the Achilles tendon to its calcaneal insertion. This hourglass pattern of FiberWire(®) provides a greater area of tendon compression, consequently allowing greater stability and possible earlier return to weightbearing activities. The patients were followed up for approximately 2 years' duration. There were no intraoperative or postoperative complications. At final follow-up there was no evidence of Achilles tendon ruptures or device failures. All patients were able to return to their activities of daily living without the use of assistive devices. The patients' average visual analog pain scale was 1 (range 0 to 4), and their average foot functional index score was 3.41 (range 0

  4. Clinical Outcome and Wound Healing following Carpal Tunnel Decompression: A Comparison of Two Common Suture Materials

    Directory of Open Access Journals (Sweden)

    Robert J. MacFarlane

    2014-01-01

    Full Text Available Introduction. Debate exists amongst surgeons regarding the ideal suture material for skin closure in carpal tunnel decompression (CTD. This study compares wound related complications, patient satisfaction, and functional outcome following open carpal tunnel decompression in patients undergoing wound closure with either of two common absorbable and nonabsorbable suture types. Materials and Methods. 53 patients underwent CTD with either 4/0 polypropylene (ProleneTM, n = 28 or 4/0 polyglactin (Vicryl RapideTM, n = 25 for skin closure. QuickDASH, VAS satisfaction scores, and Southampton wound scores were assessed preoperatively and at 2 and 6 weeks postoperatively. Results. At 6 weeks the mean QuickDASH scores postoperatively were 18.54 and 17.70 for absorbable and nonabsorbable sutures, respectively, (P = 0.86. The mean VAS scores were 0.61 and 0.42 (P = 0.91, respectively. All patients achieved a Southampton wound score of 0 by 6 weeks except one, who achieved 1C in the nonabsorbable group, equivalent to mild erythema. There were no complications in either group. Conclusion. Both suture types are safe and effective materials for CTD, and we recommend surgeons to choose according to personal preference, handling properties, and resources available for suture removal.

  5. In vivo molecular evaluation of guinea pig skin incisions healing after surgical suture and laser tissue welding using Raman spectroscopy.

    Science.gov (United States)

    Alimova, A; Chakraverty, R; Muthukattil, R; Elder, S; Katz, A; Sriramoju, V; Lipper, Stanley; Alfano, R R

    2009-09-01

    The healing process in guinea pig skin following surgical incisions was evaluated at the molecular level, in vivo, by the use of Raman spectroscopy. After the incisions were closed either by suturing or by laser tissue welding (LTW), differences in the respective Raman spectra were identified. The study determined that the ratio of the Raman peaks of the amide III (1247 cm(-1)) band to a peak at 1326 cm(-1) (the superposition of elastin and keratin bands) can be used to evaluate the progression of wound healing. Conformational changes in the amide I band (1633-1682 cm(-1)) and spectrum changes in the range of 1450-1520 cm(-1) were observed in LTW and sutured skin. The stages of the healing process of the guinea pig skin following LTW and suturing were evaluated by Raman spectroscopy, using histopathology as the gold standard. LTW skin demonstrated better healing than sutured skin, exhibiting minimal hyperkeratosis, minimal collagen deposition, near-normal surface contour, and minimal loss of dermal appendages. A wavelet decomposition-reconstruction baseline correction algorithm was employed to remove the fluorescence wing from the Raman spectra.

  6. Evaluation of the histologic reactions to commonly used suture materials in the skin and musculature of ball pythons (Python regius).

    Science.gov (United States)

    McFadden, Michael S; Bennett, R Avery; Kinsel, Michael J; Mitchell, Mark A

    2011-10-01

    To evaluate histologic reactions to 8 suture materials and cyanoacrylate tissue adhesive (CTA) in the musculature and skin of ball pythons. 30 hatchling ball pythons. In each snake, ten 1-cm skin incisions were made (day 0). At 8 sites, a suture of 1 of 8 materials was placed in the epaxial musculature, and the incision was closed with the same material. One incision was closed by use of CTA. No suture material was placed in the tenth incision, which was allowed to heal by second intention (negative control). Snakes (n = 5/group) were euthanized for harvest of treatment-site tissues at days 3, 7, 14, 30, 60, and 90. Skin and muscle sections were examined microscopically and assigned a subjective score (0 to 4) for each of the following: overall severity of inflammation, fibrosis, number of macrophages, number of granulocytes, number of perivascular lymphocytes, and degree of suture fragmentation. Subjective score analysis revealed that CTA did not cause a significant inflammatory response, compared with the negative control. All suture materials caused significantly more inflammation over all time points; for all suture materials, inflammatory response scores were significantly higher than values for the negative control 90 days after implantation. No sutures were completely absorbed by the end of the study period, and several sutures appeared to be in the process of extrusion. In snakes, CTA can be used to close small superficial incisions or lacerations with minimal inflammatory response, and sutures may undergo extrusion from tissues prior to complete absorption.

  7. Healing and evaluating guinea pig skin incision after surgical suture and laser tissue by welding using in vivo Raman spectroscopy

    Science.gov (United States)

    Alimova, A.; Sriramoju, V.; Chakraverty, R.; Muthukattil, R.; Alfano, R. R.

    2010-02-01

    Changes in collagen in the wound during the healing process of guinea pig skin following surgical incisions and LTW was evaluated using in vivo, using Raman spectroscopy. Raman spectroscopy provided information regarding the internal structure of the proteins. After the incisions were closed either by suturing or by LTW the ratio of the Raman peaks of the amide III (1247 cm-1) band to a peak at 1326 cm-1 used to evaluate the progression of collagen deposition. Histopathology was used as the gold standard. LTW skin demonstrated better healing than sutured skin, exhibiting minimal hyperkeratosis, minimal collagen deposition, near-normal surface contour, and minimal loss of dermal appendages. This work is important to plastic surgery.

  8. Comparison of two different suture-passing techniques with different suture materials and thicknesses: Biomechanical study of flexor tendons for yield points, gap formation and early post-operative status

    Directory of Open Access Journals (Sweden)

    Volkan Ergan

    2016-12-01

    Conclusion: The yield points with higher forces is expected to be preferred, but their thicknesses can be 3-0 or 4-0. Oblique suture passing should be preferred rather than longitudinal passing. Obviously, suture strengthening methods, like epitendineous running sutures and core sutures, should be used. Without these measures, even passive wrist motion can result in gap formation at the repair site. The results of this study showed that tensile properties of the repaired vary considerably with differences in suture material and design. [Hand Microsurg 2016; 5(3.000: 130-136

  9. Suturing property of tough double network hydrogels for bio-repair materials

    Science.gov (United States)

    Na, Yang Ho; Oh, Hwa Yeon; Ahn, Young Ju; Han, Youngbae

    2015-02-01

    Cartilage and meniscal lesions have limited potential for spontaneous repair. Consequently, much effort has been made to develop methods for repairing such lesions. Double-network (DN) gels are new candidate-materials for repairing such lesions. They exhibit exceptional mechanical strength and toughness in spite of their high water content. In this study, we prepared highly tough DN hydrogels and investigated the mechanical properties related to clinical implant use. The mechanical properties such as Young's modulus and suture tear-out strength were measured for the artificial replacement. The results suggest that the suture property of DN hydrogels can be adjusted by controlling the crosslinking density and monomer concentration. Finite element method was also applied to these DN hydrogels in order to check whether the fracture strength of the material is enough to meet a medical purpose.

  10. Comparison of antibacterial-coated and non-coated suture material in intraoral surgery by isolation of adherent bacteria

    Directory of Open Access Journals (Sweden)

    Klaus Pelz

    2015-09-01

    Full Text Available Objectives. In general surgery the incidence of postoperative wound infections is reported to be lower using triclosan-coated sutures. In intraoral surgery, sutures are faced with different bacterial species and the question arises whether the antibacterial-coated suture material has the same positive effects. Materials and Methods. Triclosan-coated and uncoated suture materials were applied in 17 patients undergoing wisdom tooth extraction. Postoperatively, sutures were removed and adherent bacteria were isolated, colony-forming units (cfu were counted, and species identified. Results. Oral bacteria were found in high numbers (cfu>10[sup]7[/sup] on both Vicryl and the triclosan-coated Vicryl Plus. The total number of bacteria isolated from Vicryl Plus was 37% higher than for Vicryl, mainly due to increased numbers of anaerobes. The number of bacterial strains identified was higher for Vicryl ( n=203 than for Vicryl Plus (n=198, but the number of pathogens was higher on Vicryl Plus (n=100 than on Vicryl (n=97. Fewer Gram-positive strains were found on Vicryl Plus (n=95 than on Vicryl (n=107 and, conversely, more Gram-negative strains on Vicryl Plus (103vs.96. Conclusions. In terms of the total number of oral bacteria, and especially oral pathogens, that adhered to suture material, no reduction was demonstrated for Vicryl Plus. The use of triclosan-coated suture material offers no advantage in intraoral surgery.

  11. Bundles of spider silk, braided into sutures, resist basic cyclic tests: potential use for flexor tendon repair.

    Directory of Open Access Journals (Sweden)

    Kathleen Hennecke

    Full Text Available Repair success for injuries to the flexor tendon in the hand is often limited by the in vivo behaviour of the suture used for repair. Common problems associated with the choice of suture material include increased risk of infection, foreign body reactions, and inappropriate mechanical responses, particularly decreases in mechanical properties over time. Improved suture materials are therefore needed. As high-performance materials with excellent tensile strength, spider silk fibres are an extremely promising candidate for use in surgical sutures. However, the mechanical behaviour of sutures comprised of individual silk fibres braided together has not been thoroughly investigated. In the present study, we characterise the maximum tensile strength, stress, strain, elastic modulus, and fatigue response of silk sutures produced using different braiding methods to investigate the influence of braiding on the tensile properties of the sutures. The mechanical properties of conventional surgical sutures are also characterised to assess whether silk offers any advantages over conventional suture materials. The results demonstrate that braiding single spider silk fibres together produces strong sutures with excellent fatigue behaviour; the braided silk sutures exhibited tensile strengths comparable to those of conventional sutures and no loss of strength over 1000 fatigue cycles. In addition, the braiding technique had a significant influence on the tensile properties of the braided silk sutures. These results suggest that braided spider silk could be suitable for use as sutures in flexor tendon repair, providing similar tensile behaviour and improved fatigue properties compared with conventional suture materials.

  12. Bundles of Spider Silk, Braided into Sutures, Resist Basic Cyclic Tests: Potential Use for Flexor Tendon Repair

    Science.gov (United States)

    Hennecke, Kathleen; Redeker, Joern; Kuhbier, Joern W.; Strauss, Sarah; Allmeling, Christina; Kasper, Cornelia; Reimers, Kerstin; Vogt, Peter M.

    2013-01-01

    Repair success for injuries to the flexor tendon in the hand is often limited by the in vivo behaviour of the suture used for repair. Common problems associated with the choice of suture material include increased risk of infection, foreign body reactions, and inappropriate mechanical responses, particularly decreases in mechanical properties over time. Improved suture materials are therefore needed. As high-performance materials with excellent tensile strength, spider silk fibres are an extremely promising candidate for use in surgical sutures. However, the mechanical behaviour of sutures comprised of individual silk fibres braided together has not been thoroughly investigated. In the present study, we characterise the maximum tensile strength, stress, strain, elastic modulus, and fatigue response of silk sutures produced using different braiding methods to investigate the influence of braiding on the tensile properties of the sutures. The mechanical properties of conventional surgical sutures are also characterised to assess whether silk offers any advantages over conventional suture materials. The results demonstrate that braiding single spider silk fibres together produces strong sutures with excellent fatigue behaviour; the braided silk sutures exhibited tensile strengths comparable to those of conventional sutures and no loss of strength over 1000 fatigue cycles. In addition, the braiding technique had a significant influence on the tensile properties of the braided silk sutures. These results suggest that braided spider silk could be suitable for use as sutures in flexor tendon repair, providing similar tensile behaviour and improved fatigue properties compared with conventional suture materials. PMID:23613793

  13. Medical devices; general and plastic surgery devices; classification of absorbable poly(hydroxybutyrate) surgical suture produced by recombinant DNA technology. Final rule.

    Science.gov (United States)

    2007-08-03

    The Food and Drug Administration (FDA) is classifying the absorbable poly(hydroxybutyrate) surgical suture produced by recombinant deoxyribonucleic acid (DNA) technology into class II (special controls). The special control that will apply to the device is the guidance document entitled "Class II Special Controls Guidance Document: Absorbable Poly(hydroxybutyrate) Surgical Suture Produced by Recombinant DNA Technology." The agency is classifying these devices into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of these devices. Elsewhere in this issue of the Federal Register, FDA is announcing the availability of the guidance document that will serve as the special control for this device.

  14. Central tendon splitting combined with SutureBridge double-row technique as a surgical treatment for insertional Achilles tendinopathy

    Institute of Scientific and Technical Information of China (English)

    LIN Yuan; WANG Zhi-wei; ZHANG Bo; PAN Jiang; QU Tie-bing; HAI Yong

    2013-01-01

    Background Surgical treatment of insertional Achilles tendinopathy should be considered when a variety of conservative measures fail.To achieve a satisfactory outcome,thorough debridement of the Achilles tendon is critical,besides excision of the bursitis and the calcaneal exostosis.Central tendon-splitting provides straightforward access to the calcified or degenerative tissue within the Achilles tendon.For Achilles tendon reconstruction if detachment is present,several surgical techniques have been reported.Controversy surrounds the technique can provide maximum security for reattachment of the Achilles tendon.The SutureBridge double-row construct,initially used in rotator cuff repair,is probably a good choice.Methods Ten consecutive patients with insertional Achilles tendinopathy underwent tendon reattachment using the SutureBridge technique through a central tendon-splitting approach.We retrospectively evaluated the surgical outcomes,which included pre-and postoperative visual analog scale (VAS),postoperative Maryland Foot Score (MFS),postoperative range of motion of the affected ankle,and related complications.Follow-up was performed in the outpatient department.Results One patient was lost to follow-up.Nine patients (two male and seven female; 12 feet) were reviewed with a minimum follow-up of six months (range 6-30 months).The postoperative VAS pain scores were markedly lower than the preoperative scores.Postoperative MFS was 92.1±8.0 (range 74-100).No intra-or postoperative complications were found,except for one case of delayed healing incision.At last follow-up,all affected ankles achieved their normal range of motion,and patients were able to resume daily activities without any assistive device.Conclusions Although a randomized control trial with a larger sample may be necessary to compare the central tendonsplitting combined with the SutureBridge technique with other techniques,our results confirmed that it was a promising alternative for treatment of

  15. Current manufacturing processes of drug-eluting sutures.

    Science.gov (United States)

    Champeau, Mathilde; Thomassin, Jean-Michel; Tassaing, Thierry; Jérôme, Christine

    2017-02-24

    Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Drug-eluting sutures represent the next generation of surgical sutures since they fulfill their mechanical functions but also deliver the drug in their vicinity after implantation. These implants are produced by a variety of manufacturing processes. Two general approaches can be followed: (i) the ones that add the API into the material during the manufacturing process of the suture and (ii) the ones that load the API to an already manufactured suture. Areas covered: This review provides an overview of the current manufacturing processes for drug-eluting suture production and discusses their benefits and drawbacks depending on the type of drugs. The mechanical properties and the drug delivery profile of drug-eluting sutures are highlighted since these implants must fulfill both criteria. Expert opinion: For limited drug contents, melt extrusion and electrospinning are the emerging processes since the drug is added during the suture manufacture process. Advantageously, the drug release profile can be tuned by controlling the processing parameters specific to each process and the composition of the drug-containing polymer. If high drug content is targeted, the coating or grafting of a drug layer on a pre-manufactured suture allows for preservation of the tensile strength requirements of the suture.

  16. A Novel Surgical Pre-suturing Technique for the Management of ...

    African Journals Online (AJOL)

    Journal of Surgical Technique and Case Report | Jul-Dec 2014 | Vol-6 | Issue-2. 49. A Novel Surgical ... 1Department Periodontology, Rural Dental College, Loni,. Maharashtra, India ... used for local infiltration anesthesia. 0.5‑1 ml of solution.

  17. Meta-analysis and trial sequential analysis of triclosan-coated sutures for the prevention of surgical-site infection.

    Science.gov (United States)

    de Jonge, S W; Atema, J J; Solomkin, J S; Boermeester, M A

    2017-01-01

    Triclosan-coated sutures (TCS) were developed to reduce the risk of surgical-site infection (SSI). Level 1A evidence of effectiveness has been presented in various recent meta-analyses, yet well designed RCTs have not been able to reproduce these favourable results. The aim of this study was to evaluate all available evidence critically with comprehensive analysis to seek a more reliable answer regarding the effectiveness of TCS in the prevention of SSI. PubMed, MEDLINE, Embase and Cochrane Library databases were searched from 1990 to November 2015 for RCTs that compared TCS with sutures that were exactly the same, but uncoated, in the prevention of SSI. Pooled relative risks (RRs) with corresponding 95 per cent confidence intervals were estimated using a random-effects model. Metaregression was used to substantiate subgroup effects, trial sequential analysis was employed to assess the risk of random error, and quality of evidence was determined using Grading of Recommendations Assessment, Development and Evaluation (GRADE) methodology. Twenty-one RCTs including 6462 patients were included. Risk of bias was serious. Pooled effects showed a RR of 0·72 (95 per cent c.i. 0·60 to 0·86; P < 0·001) for all publications. At a risk of 138 SSIs per 1000 procedures, the use of TCS reduced this by 39 (95 per cent c.i. 19, 55). Trial sequential analysis confirmed a RR reduction of 15 per cent for the use of TCS. GRADE assessment shows moderate-quality evidence that TCS are effective in reducing SSI. Trial sequential analysis indicates that the effect was robust, and additional data are unlikely to alter the summary effect. © 2017 BJS Society Ltd Published by John Wiley & Sons Ltd.

  18. [Assessing the effect of subcuticular buried sutures with subcutaneous closed suction drain to prevent surgical site infection in patients undergoing total cystectomy with urinary diversion using intestine].

    Science.gov (United States)

    Kanamaru, Sojun; Tsuchihashi, Kazunari; Makino, Yuki; Shimizu, Yosuke; Ito, Noriyuki

    2014-11-01

    We assessed the effect of subcuticular buried sutures with subcutaneous closed suction drain to prevent surgical site infection (SSI) in patients undergoing total cystectomy with urinary diversion using the intestine. We reviewed the clinical charts of 43 consecutive patients who underwent total cystectomy with urinary diversion using the intestine from February 2006 to March 2011 at Nishi-Kobe Medical Center. All patients received intravenous prophylactic antibiotics before and throughout surgery as well as for three days after surgery. Skin closure was performed with interrupted vertical mattress sutures with 2-0 nylon on the first 22 patients (mattress group), and with interrupted subcuticular buried sutures with 4-0 absorbable monofilament with subcutaneous closed suction drain on the remaining 21 patients (subcuticular buried suture with subcutaneous drain; SBD group). SSI occurred in 7 (31.8%) patients in the mattress group, but did not affect any patient in the SBD group. We compared risk factors for SSI between the groups, and found that the method of skin closure was significant risk factor for SSI (P = 0.005). We concluded that interrupted subcuticular buried sutures with 4-0 absorbable monofilament with subcutaneous suction drain is effective for prevention of SSI in total cystectomy with urinary diversion using the intestine.

  19. The cost of waste of consumable materials in a surgical center

    Directory of Open Access Journals (Sweden)

    Liliana Cristina de Castro

    2013-12-01

    Full Text Available OBJECTIVES: to identify the types, quantities and cost of the consumable materials sent, used, returned unopened and wasted in surgical operations; to classify the incidences of waste as avoidable or unavoidable losses, and to calculate the rate of waste of the consumable materials in the peri-operative period in the Surgical Center of a São Paulo university hospital. METHOD: a descriptive-exploratory case study with a quantitative approach. The convenience sample corresponded to 105 types of consumable materials sent for the 275 operations observed between February and May 2011. RESULTS: the items wasted most were surgical sutures, surgical cotton sutures, and gauze compresses. The total cost of the waste was R$ 709.84. The mean percentage of waste in the sample was 9.34%, of which 1.23% was avoidable and 8.14% unavoidable. CONCLUSION: the study evidenced that the effective management of material resources reduces the costs of the processes, and reduces waste.

  20. Effects of suture material and ultrasonic transmitter size on survival, growth, wound healing, and tag expulsion in rainbow trout

    Science.gov (United States)

    Ivasauskas, Tomas J.; Bettoli, P.W.; Holt, T.

    2012-01-01

    We examined the effects of suture material (braided silk versus Monocryl) and relative ultrasonic transmitter size on healing, growth, mortality, and tag retention in rainbow trout Oncorhynchus mykiss. In experiment 1, 40 fish (205-281mmtotal length [TL], 106-264 g) were implanted with Sonotronics IBT-96-2 (23??7 mm; weight in air, 4.4 g; weight in water, 2.4 g) or IBT 96-2E (30 ?? 7 mm; weight in air, 4.9 g; weight in water, 2.4 g) ultrasonic telemetry tags. In experiment 2, 20 larger fish (342-405 mm TL; 520-844 g) were implanted with Sonotronics IBT-96-5 ultrasonic tags (36 ?? 11 mm; weight in air, 9.1 g; weight in water, 4.1 g). The tag burdens for all implanted fish ranged from 1.1% to 3.4%, and fish in both studies were held at 10-15??C. At the conclusion of both experiments (65 d after surgery), no mortalities were observed in any of the 60 tagged fish, most incisions were completely healed, and all fish in both experiments grew in length, although tagged fish grew more slowly than control fish in experiment 1. In both experiments, fish sutured with silk expelled tags more frequently than those sutured with Monocryl. Expulsion was observed in 45-50% of the fish sutured with silk and 0-25% of the fish sutured withMonocryl. Tag expulsion was not observed until 25-35 d after surgery. Fish sutured with silk exhibited a more severe inflammatory response 3 weeks after surgery than those sutured with Monocryl. In experiment 1, the rate of expulsion was linked to the severity of inflammation. Although braided silk sutures were applied faster than Moncryl sutures in both experiments, knots tied with either material were equally reliable and fish sutured with Monocryl experienced less inflammation and lower rates of tag expulsion. American Fisheries Society 2012.

  1. Craniofacial clefting and sutural dystopia.

    Science.gov (United States)

    Moore, M H; Edwards, T J; David, D J

    1991-07-01

    Sutural anomalies in conjunction with craniofacial clefting are unusual. A case of median frontal clefting is presented in which there was an absence of a normal metopic suture and replacement by paramedian frontal sutures. The association of an underlying brain anomaly, with attendant surgical difficulties, is noted, as are the radiological techniques of preoperative diagnosis.

  2. Analysis of individualized education programs to quantify long-term educational needs following surgical intervention for single-suture craniosynostosis.

    Science.gov (United States)

    Doshier, Laura J; Muzaffar, Arshad R; Deidrick, Kathleen Km; Rice, Gale B

    2015-01-01

    Single-suture craniosynostosis (SSC) is a common craniofacial condition with potential neurocognitive sequelae. To quantify any long-term functional academic and behavioural difficulties of children with SSC as indicated by the need for individualized education programs (IEPs), despite having undergone surgical treatment. Records of all school-age patients from 1992 to 2011 who underwent operative intervention for SSC were identified. Fifty-nine patients' guardians were contacted by telephone to provide informed consent for completion of a mailed standardized questionnaire querying demographic information as well as information regarding the patient's health, family and educational history; specifically whether the patient had ever been provided educational support as delineated in an IEP. The primary outcome measure was the history of the patient being assigned educational support as delineated in an IEP. Thirty-seven consenting guardians completed and returned the standardized questionnaire (response rate 62.7%). Twenty-one patients were male and 16 were female, with an age range of five to 14 years (mean age 10.2 years). Eleven (29.7%) patients had a previous history of or currently were receiving educational support delineated in an IEP. A higher proportion of school-age patients with a history of SSC (status postsurgical intervention) in the present study received educational support delineated in an IEP than the proportion of IEPs in the general student population of the United States (11.3%).

  3. Evaluation of the effect of 4 types of knots on the mechanical properties of 4 types of suture material used in small animal practice.

    Science.gov (United States)

    Avoine, Xytilis; Lussier, Bertrand; Brailovski, Vladimir; Inaekyan, Karine; Beauchamp, Guy

    2016-04-01

    The influence of the type of material used, knot configuration, and use of an additional throw on the tensile force at failure, the elongation, and the mode of failure of different configurations of linear sutures and knotted suture loops was evaluated in this in-vitro mechanical study. We hypothesized that all types of knots would significantly influence the initial force and elongation of suture materials and would influence the force and elongation at which the knotted loops break, but not their mode of failure. A total of 432 samples of 4 types of size 3-0 suture material (polydioxanone, polyglecaprone 25, polyglactin 910, and nylon), representing 9 configurations, were tested in a tensiometer. The configurations were 1 linear suture without a knot and the following loops: square (SQ) knot; surgeon's (SU) knot; granny (GR) knot; and sliding half-hitch (SHH) knot using either 4 and 5 or 3 and 4 throws, depending on the material. For polydioxanone, SQ and SU knots did not decrease the initial force at failure of the suture. Granny (GR) and SHH knots decreased the tensile force at failure and elongation by premature failure of the loop. For polyglecaprone 25, all knots decreased the initial force at failure of the suture, with SHH being weaker than the other knots. For coated polyglactin 910, all knots decreased the initial force at failure of the suture and slippage increased significantly compared with the other 3 sutures. The use of SQ knots with 3 throws did not result in a safe knot. For nylon, knots did not alter the original mechanics of the suture. In conclusion, all knots and types of suture material do not necessarily have the same effect on the initial tensile force at failure of suture materials.

  4. Fiber from ramie plant (Boehmeria nivea): A novel suture biomaterial

    Energy Technology Data Exchange (ETDEWEB)

    Kandimalla, Raghuram; Kalita, Sanjeeb; Choudhury, Bhaswati [Drug discovery laboratory, Institute of Advanced Study in Science and Technology, Guwahati, Assam 781035 (India); Devi, Dipali [Seri biotech laboratory, Institute of Advanced Study in Science and Technology, Guwahati, Assam 781035 (India); Kalita, Dhaneswar [Government Ayurvedic College and Hospital, Jalukbari, Guwahati, Assam 781014 (India); Kalita, Kasturi [Department of Pathology, Hayat Hospital, Guwahati, Assam 781034 (India); Dash, Suvakanta [Girijananda Chowdhury Institute of pharmaceutical science, Azara, Guwahati, Assam 781017 (India); Kotoky, Jibon, E-mail: jkotoky@gmail.com [Drug discovery laboratory, Institute of Advanced Study in Science and Technology, Guwahati, Assam 781035 (India)

    2016-05-01

    various biomedical applications. - Highlights: • This study describes the utilization of ramie plant fiber as surgical suture material for biomedical applications. • The ramie suture possesses excellent biocompatibility and efficiently heals superficial wounds. • The ramie suture is comparable with market available silk suture and the former one has inherent antibacterial property. • Ramie suture is much cost effective than market available sutures which can decrease the healthcare cost by many folds.

  5. Shear lag sutures: Improved suture repair through the use of adhesives.

    Science.gov (United States)

    Linderman, Stephen W; Kormpakis, Ioannis; Gelberman, Richard H; Birman, Victor; Wegst, Ulrike G K; Genin, Guy M; Thomopoulos, Stavros

    2015-09-01

    Suture materials and surgical knot tying techniques have improved dramatically since their first use over five millennia ago. However, the approach remains limited by the ability of the suture to transfer load to tissue at suture anchor points. Here, we predict that adhesive-coated sutures can improve mechanical load transfer beyond the range of performance of existing suture methods, thereby strengthening repairs and decreasing the risk of failure. The mechanical properties of suitable adhesives were identified using a shear lag model. Examination of the design space for an optimal adhesive demonstrated requirements for strong adhesion and low stiffness to maximize the strength of the adhesive-coated suture repair construct. To experimentally assess the model, we evaluated single strands of sutures coated with highly flexible cyanoacrylates (Loctite 4903 and 4902), cyanoacrylate (Loctite QuickTite Instant Adhesive Gel), rubber cement, rubber/gasket adhesive (1300 Scotch-Weld Neoprene High Performance Rubber & Gasket Adhesive), an albumin-glutaraldehyde adhesive (BioGlue), or poly(dopamine). As a clinically relevant proof-of-concept, cyanoacrylate-coated sutures were then used to perform a clinically relevant flexor digitorum tendon repair in cadaver tissue. The repair performed with adhesive-coated suture had significantly higher strength compared to the standard repair without adhesive. Notably, cyanoacrylate provides strong adhesion with high stiffness and brittle behavior, and is therefore not an ideal adhesive for enhancing suture repair. Nevertheless, the improvement in repair properties in a clinically relevant setting, even using a non-ideal adhesive, demonstrates the potential for the proposed approach to improve outcomes for treatments requiring suture fixation. Further study is necessary to develop a strongly adherent, compliant adhesive within the optimal design space described by the model.

  6. Suture-induced right coronary artery stenosis.

    Science.gov (United States)

    Seltmann, Martin; Achenbach, Stephan; Muschiol, Gerd; Feyrer, Richard

    2010-01-01

    An 82-year-old patient developed right heart failure in the days after surgical aortic valve replacement. Coronary CT angiography showed a high-grade stenosis of the mid-right coronary artery. Adjacent suture material seen on noncontrast CT suggested that the lesion was related to surgical closure of the right atrial cannulation site. Invasive angiography confirmed the stenosis, and percutaneous intervention was successfully performed.

  7. Recent advances in biodegradable metals for medical sutures: a critical review.

    Science.gov (United States)

    Seitz, Jan-Marten; Durisin, Martin; Goldman, Jeremy; Drelich, Jaroslaw W

    2015-09-16

    Sutures that biodegrade and dissolve over a period of several weeks are in great demand to stitch wounds and surgical incisions. These new materials are receiving increased acceptance across surgical procedures whenever permanent sutures and long-term care are not needed. Unfortunately, both inflammatory responses and adverse local tissue reactions in the close-to-stitching environment are often reported for biodegradable polymeric sutures currently used by the medical community. While bioabsorbable metals are predominantly investigated and tested for vascular stent or osteosynthesis applications, they also appear to possess adequate bio-compatibility, mechanical properties, and corrosion stability to replace biodegradable polymeric sutures. In this Review, biodegradable alloys made of iron, magnesium, and zinc are critically evaluated as potential materials for the manufacturing of soft and hard tissue sutures. In the case of soft tissue closing and stitching, these metals have to compete against currently available degradable polymers. In the case of hard tissue closing and stitching, biodegradable sternal wires could replace the permanent sutures made of stainless steel or titanium alloys. This Review discusses the specific materials and degradation properties required by all suture materials, summarizes current suture testing protocols and provides a well-grounded direction for the potential future development of biodegradable metal based sutures.

  8. 21 CFR 878.4495 - Stainless steel suture.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Stainless steel suture. 878.4495 Section 878.4495...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture. (a) Identification. A stainless steel suture is a needled or unneedled nonabsorbable surgical suture composed of...

  9. Surgical repair of acute Achilles tendon rupture with an end-to-end tendon suture and tendon flap.

    Science.gov (United States)

    Corradino, B; Di Lorenzo, S; Calamia, C; Moschella, F

    2015-08-01

    Achilles tendon ruptures are becoming more common. Complications after open or minimally invasive surgery are: recurrent rupture (2-8%), wound breakdown, deep infections, granuloma, and fistulas. The authors expose their experience with a personal technique. In 8 patients with acute rupture of Achilles tendon the surgery was performed at least 25 days after trauma. Clinical exam and MR demonstrated in all case a total lesion of tendon. After a posterolateral skin incision the tendon stumps were debrided and suture in end-to-end fashion. A tendon flap was harvested from the proximal part of the tendon, in order to protect and reinforce the suture itself. A plaster cast was applied for 3 weeks and the patients started the rehabilitation protocol. After 4 months all patients returned to pre-injury daily activities. The mean follow up was 13 months (ranged between 6 and 24 months). No major complications occurred. The posterolateral skin incision, not above the tendon, preserves the vascularity of the soft tissues, allows identifying and not accidentally injuring the sural nerve, and prevents the cutaneous scar is overlapped the tendon. In this way is favoured physiological tendon sliding. The preparation of the flap tendon does not weaken the overall strength of the tendon and protects the tendon suture. The tension on sutured stumps is less than being spread over a larger area. In our sample of 8 patients the absence of short-and long-term complications and the rapid functional recovery after surgery suggest that the technique used is safe and effective. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. The impact of bone and suture material properties on mandibular function in Alligator mississippiensis: testing theoretical phenotypes with finite element analysis

    Science.gov (United States)

    Reed, David A; Porro, Laura B; Iriarte-Diaz, Jose; Lemberg, Justin B; Holliday, Casey M; Anapol, Fred; Ross, Callum F

    2011-01-01

    Abstract The functional effects of bone and suture stiffness were considered here using finite element models representing three different theoretical phenotypes of an Alligator mississippiensis mandible. The models were loaded using force estimates derived from muscle architecture in dissected specimens, constrained at the 18th and 19th teeth in the upper jaw and 19th tooth of the lower jaw, as well as at the quadrate-articular joint. Stiffness was varied systematically in each theoretical phenotype. The three theoretical phenotypes included: (i) linear elastic isotropic bone of varying stiffness and no sutures; (ii) linear elastic orthotropic bone of varying stiffness with no sutures; and (iii) linear elastic isotropic bone of a constant stiffness with varying suture stiffness. Variation in the isotropic material properties of bone primarily resulted in changes in the magnitude of principal strain. By comparison, variation in the orthotropic material properties of bone and isotropic material properties of sutures resulted in: a greater number of bricks becoming either more compressive or more tensile, changing between being either dominantly compressive or tensile, and having larger changes in the orientation of maximum principal strain. These data indicate that variation in these model properties resulted in changes to the strain regime of the model, highlighting the importance of using biologically verified material properties when modeling vertebrate bones. When bones were compared within each set, the response of each to changing material properties varied. In two of the 12 bones in the mandible, varied material properties within sutures resulted in a decrease in the magnitude of principal strain in bricks adjacent to the bone/suture interface and decreases in stored elastic energy. The varied response of the mandibular bones to changes in suture stiffness highlights the importance of defining the appropriate functional unit when addressing relationships of

  11. Experimental evaluation of horse hair as a nonabsorbable monofilament suture

    Directory of Open Access Journals (Sweden)

    Swati R Yedke

    2013-01-01

    Full Text Available Background: Success of surgery depends on wound closure and healing. Ancients had coated many suture materials from plant and animal origin. As the quest for natural nonabsorbable, monofilament surgical suture continues, horsehair has been taken for study, which is mentioned in ancient literature. Objectives: Aim of the study was to evaluate detail mechanical and biophysical properties of horsehair. Materials and Methods: Physical properties, that are diameter, straight pull and knot pull tensile strength, bioburden, sterility tests were performed. Visual and histological wound healing parameters were studied in experimental Wistar rat incision wound model. Two experimental wounds about 5 cm long were created on each side of dorsal midline. Each animal received two sutures-Horsehair 4-0 and Ethilon 4-0. The sutured areas were grossly examined on 3 rd and 7 th days for visual observations like congestion, edema, infection, wound disruption, and impression of suture material on healed wound and then subjected for histological study. Results: Revealed that horsehair has got diameter of 0.19 mm which complies with the 4-0 size USP standard. Straight pull tensile strength was found 0.5851 ± 0.122 kg and knot pull tensile strength was 0.3998 ± 0.078 kg, which complies with the standards of United State Pharmacopia for class II nonabsorbable suture materials. In vivo study revealed that there was no evidence of edema, congestion, and discharge in both the groups. Wounds healed with minimum impressions of suture material with minimum scar mark. Mean histological scoring shows very mild tissue reaction. Conclusion: Horsehair has got properties of standard suture material except low tensile strength and hence can be used in reconstructive, plastic surgeries, and ophthalmic surgeries.

  12. Eventos adversos e queixas técnicas relacionados ao fi o para sutura cirúrgica comercializado no Brasil / Adverse events and technical complaints related to surgical sutures marketed in Brazil

    Directory of Open Access Journals (Sweden)

    Luciene de Oliveira Morais

    2013-05-01

    Full Text Available O fi o para sutura cirúrgica (FPS é um produto médico invasivo utilizado para aproximação de tecido biológico e, devido ao contato com a pele, vasculatura e outros tecidos, é considerado um produto crítico. O presente estudo objetivou a análise crítica dos dados do Sistema Nacional de Notifi cações de Eventos Adversos e Queixas Técnicas (Notivisa, relacionados aos FPSs, através de avaliação minuciosa da descrição das notifi cações realizadas entre 2006 e 2009. Foram registradas 256 ocorrências associadas ao FPS, sendo 94 (36,7% episódios de eventos adversos e 162 (63,3% de queixas técnicas. Algumas divergências conceituais e registros incompletos foram observados. Merecem destaque as notifi cações relacionadas ao próprio fi o, como seu rompimento e sua baixa resistência, assim como alterações relacionadas à agulha acoplada ao FPS. Verifi cou-se que 51% das empresas detentoras de registro de FPS no Brasil apresentaram alguma notifi cação no Notivisa e que, ao todo, 28 lotes apresentaram mais de uma notifi cação. Esses dados reforçam a importância da implementação da certifi cação compulsória para esses produtos, estabelecendo requisitos mínimos de qualidade obrigatórios, e demonstram a necessidade de permanente capacitação dos profi ssionais envolvidos no processo de notifi cação. Desse modo, a notifi cação mais rápida e precisa auxiliaria a tomada de medidas oportunas pelo SNVS e pelo detentor do registro, de forma a impedir, ou minimizar, a ocorrência de agravos à saúde das populações expostas. ------------------------------------------------------------------Surgical suture (SS is a medical material used invasively for positioning biological tissues and is regarded as a critical product due to its contact with skin, vessels and other tissues. The present study aimed to critically analyze the Brazilian National Adverse Event and Product Complaint Reporting (Notivisa data

  13. Estudo comparativo das reações teciduais produzidas pela "linha de pesca" (poliamida e fio de náilon cirúrgico Comparative study of tissue reaction produced by fishing line (polyamideand surgical nylon suture

    Directory of Open Access Journals (Sweden)

    Sheila Canevese Rahal

    1998-03-01

    Full Text Available Foram empregados 30 ratos, machos, linhagem Wistar. Implantou-se sob a pele segmentos de 3cm de comprimento de "linha de pesca " mantida em formalina, "linha de pesca " autoclavada uma vez, "linha de pesca " autoclavada duas vezes e fio de náilon cirúrgico. Cada animal recebeu dois tipos de material de sutura, em locais paralelos e eqüidistantes da coluna vertebral. Foram sacrificados com cinco, 15 e 90 dias de pós-operatório para que se procedesse o exame histopatológico. Pelo grau de reação tecidual pode-se concluir que: a maior reação ocorreu com a "linha de pesca mantida em formalina e a menor com o fio de náilon cirúrgico; as "linhas de pesca " autoclavadas uma e duas vezes se comportaram de forma semelhante e apresentaram um reação intermediária.Thirty male Wistar rats were implanted under the skin with surgical nylon or fishing line maintained in formalin or fishing line autoclaved once or twice. Two different types of 3cm length suture material were implanted in each animal parallel and equidistant sites from the vertebral column. The animals were sacrificed at five, 15 and 90 days postoperative for histopathological examination. The greatest tissue reaction was observed in those animals implanted with fishing line maintained in formalin and the smallest reaction in those implanted with surgical nylon. Animals implanted with once and twice autoclaved fishing line showed similar and intermediary reaction.

  14. 急性共同性内斜视矫正手术中可调节缝线的效果观察%Observation of effect of surgical correction of strabismus with adjustable suture in treating acute comitant esotropia

    Institute of Scientific and Technical Information of China (English)

    秦剑英; 周畅达; 赵华; 徐深

    2011-01-01

    Objective To observe the efficiency of surgical correction of strabismus with adjustable suture in treating acute concomitant esotropia. Methods 12 acute concomitant esotropia cases were treated by surgical correction of strabismus with adjustable suture and synoptophore training for 15 days postoperatively. Results Postoperative diplopia: 11 cases regained binocular single vision without diplopia at the near or far distance. 1 case remained 8 prism diopters(PD) esotropia postoperatively, with no diplopia within 1 meter and diplopia alleviated significantly beyond 1 meter. Conclusion The effect of surgical correction of strabismus with adjustable suture in treating acute concomitant esotropia is satisfactory.%目的 观察术中置可调节缝线矫正急性共同性内斜视的效果.方法 12例急性共同性内斜视进行手术治疗,术中置可调节缝线,术后同视机训练15 d.结果 术后复视情况:11例看远看近复视消失,均恢复双眼单视;1例欠矫8△,1 m以内复视消失,1 m以外复视较前明显减轻.结论 急性共同性内斜视全矫手术置可调节缝线效果良好.

  15. Surgical induced astigmatism correlated with corneal pachymetry and intraocular pressure: transconjunctival sutureless 23-gauge versus 20-gauge sutured vitrectomy in diabetes mellitus

    Institute of Scientific and Technical Information of China (English)

    Yan; Shao; Li-Jie; Dong; Yan; Zhang; Hui; Liu; Bo-Jie; Hu; Ju-Ping; Liu; Xiao-Rong; Li

    2015-01-01

    AIM: To determine the difference of surgical induced astigmatism between conventional 20-gauge sutured vitrectomy and 23-gauge transconjunctival sutureless vitrectomy, and the influence of corneal pachymetry and intraocular pressure(IOP) on surgical induced astigmatism in diabetic patients.METHODS: This retrospective, consecutive case series consisted of 40 eyes of 38 diabetic subjects who underwent either 20-gauge or 23-gauge vitrectomy. The corneal curvature and thickness were measured with Scheimpflug imaging before surgery and 1wk; 1, 3mo after surgery. We compared the surgical induced astigmatism(SIA) on the true net power in 23-gauge group with that in 20-gauge group. We determined the correlation between corneal thickness change ratio, IOP and SIA measured by Pentacam. RESULTS: The mean SIAs were 1.082 ±0.085 D( mean ± SEM), 0.689 ±0.070 D and 0.459 ±0.063 D at postoperative 1wk; 1, 3mo respectively in diabetic subjects. The vitrectomy induced astigmatisms were declined significantly with time(F2,36=33.629, P =0.000)postoperatively. The 23-gauge surgery group induced significantly less astigmatism than 20-gauge surgery group(F1,37=11.046, P =0.020). Corneal thickness in diabetes elevated after surgery(F3,78=10.532, P =0.000).The linear regression analysis at postoperatively 1wk went as: SIA =-4.519 +4.931 change ratio(Port3) +0.026IOP(R2=0.46, P =0.000), whereas the rate of cornealthickness change and IOP showed no correlation with the change of astigmatism at postoperatively 1 and 3mo.CONCLUSION: There are significant serial changes in both 20-gauge and 23-gauge group in diabetic subjects.23-gauge induce less astigmatism than 20-gauge and become stable more rapidly than 20-gauge. The elevation of corneal thickness and IOP was associated with increased astigmatim at the early postoperative stage both in 23-gauge and 20-gauge surgery group.

  16. [Influence of tendon surgery training on the quality of the suture].

    Science.gov (United States)

    Poniński, Michał; Tokarski, Maciej; Andrzejewski, Tomasz; Czarnecki, Piotr; Spławski, Robert

    2010-01-01

    Injuries of flexor tendons are one of the most common injuries that need surgical treatment at emergency room. Technique and quality of the surgery was performed are two factors of the utmost importance. The aim of the study was to determine influence of basic surgical training on the quality of suture. Research was divided into four surgical sessions which were held each once a week. Sutures were put by three medical students. Material that was used were deep flexor tendons dissected from fresh pig's legs. Sessions 1st, 2nd and 4th were preceded by training done by experienced surgeon. During study 90 modified-Kessler sutures without additional running suture were made. Breaking strength was assesed by tensile machine (INSTRON 4481). Time of each suture was also recorded. Outcomes were analyzed by tests: ANOVA and post-hoc LSD tests. Time significantly dropped by 64% after the first session and was held on the same level. Strength of sutures rises in each session preceded by training. There was statistically significant difference between session 1 (mean 13.58; SD 9.86N) and 2nd (mean 42.69; SD 9.27N) and 3rd (mean 38.42; SD 12.28N) and 4th (mean 57.12; SD 12.78N). Conclusions. Time of procedure significantly dropped after first teaching course and was held on the same level despite further training. Breaking strength rise in every session that was preceded by teaching course.

  17. Ab-interno scleral suture loop fixation with cow-hitch knot in posterior chamber intraocular lens decentration

    OpenAIRE

    Ertugrul Can; Nurullah Koçak; Özlem Eski Yücel; Adem Gül; Hilal Eser Öztürk; Osman Sayin

    2016-01-01

    Aim of Study: To describe a simplified ab-interno cow-hitch suture fixation technique for repositioning decentered posterior chamber intraocular lens (PC IOL). Materials and Methods: Two cases are presented with the surgical correction of decentered and subluxated IOL. Ab-interno scleral suture fixation technique with hitch-cow knot in the eye was performed with a ciliary sulcus guide instrument and 1 year follow-up was completed. Results: Both of the patients had well centered lenses postope...

  18. Comparison of surgical procedures for vascular and airway anastomoses that utilize a modified non-suture external cuff technique for experimental lung transplantation in rats.

    Science.gov (United States)

    Mizobuchi, Teruaki; Sekine, Yasuo; Yasufuku, Kazuhiro; Fujisawa, Takehiko; Wilkes, David S

    2004-07-01

    Lung transplantation in rats is technically difficult and results may vary. The non-suture cuff technique (non-suture [NS]), which involves using a cuff for anastomoses of vessels and airways, is commonly utilized to perform transplant procedures. However, the standard bronchial cuff may occlude the lumen, resulting in diminished graft survival. In contrast, the non-suture cuff technique for vascular anastomoses with bronchial suturing (bronchial suture [BS]), although more technically difficult, is known to have prolonged bronchial patency. We developed a "modified" NS technique that uses a larger and longer cuff for anastomoses and compared the efficacy of this procedure to the BS technique for lung transplantation. The BS procedure was performed in 146 transplant procedures. The modified NS procedure, which uses a larger cuff than the standard NS procedure, was performed in 113 procedures. Although total ischemic times were comparable, the total operation time in the NS group was significantly shorter than in the BS group (p technique is widely acknowledged to provide prolonged patency of bronchial anastomosis, graft survival in the NS group was observed up 17 months post-transplant. These data show that the NS technique, which is less technically difficult, results in shorter operative times compared with the BS procedure, and results in durable anastomoses of lung grafts.

  19. Optimal Needle Grasp Selection for Automatic Execution of Suturing Tasks in Robotic Minimally Invasive Surgery

    OpenAIRE

    Liu, Taoming; Çavuşoğlu, M. Cenk

    2015-01-01

    This paper presents algorithms for optimal selection of needle grasp, for autonomous robotic execution of the minimally invasive surgical suturing task. In order to minimize the tissue trauma during the suturing motion, the best practices of needle path planning that are used by surgeons are applied for autonomous robotic surgical suturing tasks. Once an optimal needle trajectory in a well-defined suturing scenario is chosen, another critical issue for suturing is the choice of needle grasp f...

  20. Comparative evaluation of sutures coated with triclosan and chlorhexidine for oral biofilm inhibition potential and antimicrobial activity against periodontal pathogens: An in vitro study

    Directory of Open Access Journals (Sweden)

    Kunal Sunder Sethi

    2016-01-01

    Full Text Available Background: Surgical site plaque accumulation is one of the challenging problems leading to unfavorable healing. The antibacterial sutures can be used to reduce or inhibit plaque formation. Presently there is no study comparing efficacy of sutures coated with triclosan and chlorhexidine in terms of oral biofilm inhibition and antimicrobial property against periodontal pathogens. Aim: The aim of present study was to evaluate the antibacterial efficacy and oral biofilm inhibition around chlorhexidine and triclosan coated polyglactin sutures in comparison to uncoated sutures. Materials and Method: Equal segments of chlorhexidine and triclosan coated polyglactin sutures (3-0 were incubated at 370°C in saliva collected from 10 chronic periodontitis patients for 7 days. Plain uncoated suture served as control. Biofilm formation was analyzed with Confocal Laser-Scanning Microscopy (CLSM and Scanning Electron Microscopy (SEM. Quantitative assessment was done using Colony Forming Units (CFU/mL.The antibacterial efficacy of the sutures was tested against specific periodontal pathogens (S.mutans, F.nucleatum, A.actinomycetomcomitans, P.intermedia, P.gingivalis using agar diffusion method. CLSM and SEM were not subjected to statistical analysis. ANOVA test was used for colony forming units and agar diffusion test. (P < 0.05 Results: CLSM and SEM showed substantial biofilm inhibition around chlorhexidine-coated sutures followed by triclosan-coated when compared to plain uncoated suture. The antibacterial coated sutures showed statistically significant difference in CFUs/ml and zone of inhibition compared to plain uncoated sutures. Among coated sutures, chlorhexidine-coated sutures showed better results. Conclusion: The antibacterial coated sutures have a promising potential in preventing the colonization of periodontal pathogens around it thereby inhibiting biofilm formation.

  1. Modality of wound closure after total knee replacement: are staples as safe as sutures? A retrospective study of 181 patients

    Directory of Open Access Journals (Sweden)

    Hammerberg E Mark

    2011-10-01

    Full Text Available Abstract Background Surgical site wound closure plays a vital role in post-operative success. This effect is magnified in regard to commonly performed elective procedures such as total knee arthroplasty. The use of either sutures or staples for skin re-approximation remains a contested subject, which may have a significant impact on both patient safety and surgical outcome. The literature remains divided on this topic. Methods Two cohorts of patients at a level one trauma and regional referral center were reviewed. Cohorts consisted of consecutive total knee arthroplasties performed by two surgeons who achieved surgical wound re-approximation by either staples or absorbable subcuticular sutures. Outcome variables included time of surgery, wound dehiscence, surgical site infection per Center for Disease Control criteria and repeat procedures for debridement and re-closure. Results 181 patients qualified for study inclusion. Staples were employed in 82 cases (45.3% of total and sutures in 99 cases (54.7%. The staples group had no complications while the sutures group had 9 (9.1%. These consisted of: 4 infections (2 superficial, one deep, one organ/space; three patients required re-suturing for dehiscence; one allergic type reaction to suture material; and one gout flare resulting in dehiscence. The mean surgical time with sutures was 122.3 minutes (sd = 33.4 and with staples was 114 minutes (sd = 24.4. Conclusion This study demonstrated significantly fewer complications with staple use than with suture use. While all complications found in this study cannot be directly attributed to skin re-approximation method, the need for further prospective, randomized trials is established.

  2. Mesenchymal stem cell-coated sutures enhance collagen depositions in sutured tissues.

    Science.gov (United States)

    Casado, Javier G; Blazquez, Rebeca; Jorge, Inmaculada; Alvarez, Veronica; Gomez-Mauricio, Guadalupe; Ortega-Muñoz, Mariano; Vazquez, Jesus; Sanchez-Margallo, Francisco M

    2014-01-01

    Sutures are commonly used for surgical procedures and new sutures are being developed to improve wound healing. In the past decade, it has been extensively shown that mesenchymal stem cells (MSCs) have a wound healing potential. To benefit the overall wound healing process, we aimed to analyze the usage of pretreated sutures for improving the implantation of MSCs in the tissues. Our results firstly showed that suture pretreatments with gelatin, poly-L-lysine, and NaOH improved the adhesive strength of MSCs to sutures. These cells remained surrounding the sutured tissue and no significant phenotypic changes were found in those cells cultured onto pretreated sutures. In vivo experiments showed that the implantation of MSCs by suturing increases the collagen content in the sutured tissue. Moreover, proteomics analysis of secreted proteins showed that collagen alpha-1(I) chain was the most abundant collagen found. To our knowledge, this is the first report that aimed to improve the implantation of MSCs in tissue by suture pretreatments. Moreover, in vivo experiments suggest that MSC-coated sutures may enhance wound healing and tissue remodeling through the release of different collagen types being applicable for those patients that tend to have difficulty healing.

  3. Biologic properties of surgical scaffold materials derived from dermal ECM.

    Science.gov (United States)

    Kulig, Katherine M; Luo, Xiao; Finkelstein, Eric B; Liu, Xiang-Hong; Goldman, Scott M; Sundback, Cathryn A; Vacanti, Joseph P; Neville, Craig M

    2013-07-01

    Surgical scaffold materials manufactured from donor human or animal tissue are increasingly being used to promote soft tissue repair and regeneration. The clinical product consists of the residual extracellular matrix remaining after a rigorous decellularization process. Optimally, the material provides both structural support during the repair period and cell guidance cues for effective incorporation into the regenerating tissue. Surgical scaffold materials are available from several companies and are unique products manufactured by proprietary methodology. A significant need exists for a more thorough understanding of scaffold properties that impact the early steps of host cell recruitment and infiltration. In this study, a panel of in vitro assays was used to make direct comparisons of several similar, commercially-available materials: Alloderm, Medeor Matrix, Permacol, and Strattice. Differences in the materials were detected for both cell signaling and scaffold architecture-dependent cell invasion. Material-conditioned media studies found Medeor Matrix to have the greatest positive effect upon cell proliferation and induction of migration. Strattice provided the greatest chemotaxis signaling and best suppressed apoptotic induction. Among assays measuring structure-dependent properties, Medeor Matrix was superior for cell attachment, followed by Permacol. Only Alloderm and Medeor Matrix supported chemotaxis-driven cell invasion beyond the most superficial zone. Medeor Matrix was the only material in the chorioallantoic membrane assay to support substantial cell invasion. These results indicate that both biologic and structural properties need to be carefully assessed in the considerable ongoing efforts to develop new uses and products in this important class of biomaterials. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Visual Measurement of Suture Strain for Robotic Surgery

    Directory of Open Access Journals (Sweden)

    John Martell

    2011-01-01

    Full Text Available Minimally invasive surgical procedures offer advantages of smaller incisions, decreased hospital length of stay, and rapid postoperative recovery to the patient. Surgical robots improve access and visualization intraoperatively and have expanded the indications for minimally invasive procedures. A limitation of the DaVinci surgical robot is a lack of sensory feedback to the operative surgeon. Experienced robotic surgeons use visual interpretation of tissue and suture deformation as a surrogate for tactile feedback. A difficulty encountered during robotic surgery is maintaining adequate suture tension while tying knots or following a running anastomotic suture. Displaying suture strain in real time has potential to decrease the learning curve and improve the performance and safety of robotic surgical procedures. Conventional strain measurement methods involve installation of complex sensors on the robotic instruments. This paper presents a noninvasive video processing-based method to determine strain in surgical sutures. The method accurately calculates strain in suture by processing video from the existing surgical camera, making implementation uncomplicated. The video analysis method was developed and validated using video of suture strain standards on a servohydraulic testing system. The video-based suture strain algorithm is shown capable of measuring suture strains of 0.2% with subpixel resolution and proven reliability under various conditions.

  5. Experimental study on tissue phantoms to understand the effect of injury and suturing on human skin mechanical properties.

    Science.gov (United States)

    Chanda, Arnab; Unnikrishnan, Vinu; Flynn, Zachary; Lackey, Kim

    2017-01-01

    Skin injuries are the most common type of injuries occurring in day-to-day life. A skin injury usually manifests itself in the form of a wound or a cut. While a shallow wound may heal by itself within a short time, deep wounds require surgical interventions such as suturing for timely healing. To date, suturing practices are based on a surgeon's experience and may vary widely from one situation to another. Understanding the mechanics of wound closure and suturing of the skin is crucial to improve clinical suturing practices and also to plan automated robotic surgeries. In the literature, phenomenological two-dimensional computational skin models have been developed to study the mechanics of wound closure. Additionally, the effect of skin pre-stress (due to the natural tension of the skin) on wound closure mechanics has been studied. However, in most of these analyses, idealistic two-dimensional skin geometries, materials and loads have been assumed, which are far from reality, and would clearly generate inaccurate quantitative results. In this work, for the first time, a biofidelic human skin tissue phantom was developed using a two-part silicone material. A wound was created on the phantom material and sutures were placed to close the wound. Uniaxial mechanical tests were carried out on the phantom specimens to study the effect of varying wound size, quantity, suture and pre-stress on the mechanical behavior of human skin. Also, the average mechanical behavior of the human skin surrogate was characterized using hyperelastic material models, in the presence of a wound and sutures. To date, such a robust experimental study on the effect of injury and sutures on human skin mechanics has not been attempted. The results of this novel investigation will provide important guidelines for surgical planning and validation of results from computational models in the future.

  6. A pulled sutures technique for bony Bankart lesion.

    Science.gov (United States)

    Lee, Byung Ill; Choi, Hyung Suk; Min, Kyung Dae; Kwon, Sai Won; Kim, Jun Bum; Kim, Yong-Beom; Chun, Dong-Il

    2014-05-01

    In an attempt to present a new surgical technique for arthroscopic bony Bankart fixation, the authors developed the pulled sutures technique. In executing the new method, the authors first passed several non-absorbable sutures through labroligamentous tissue with displaced articular fragment by mimicking transglenoid suture technique. Aimed at achieving a safe and stable fixation, using a knotless anchor rather than transglenoid suture, was deployed. Overall, this pulled sutures technique was shown to be effective with the result of direct reduction, stable, and safe fixation for bony Bankart's lesion.

  7. An Atypical Etiology of Suprasphincteric Fistula: A Forgotten Surgical Material

    Directory of Open Access Journals (Sweden)

    Melih Paksoy

    2010-01-01

    Full Text Available While the majority of fistulas in ano result from infection of the anal crypts, complex, recurrent, and/or nonhealing fistulas should always raise the suspicion of a chronic underlying condition. In this paper, we present a 30-year-old male patient with a diagnosis of a complex suprasphincteric fistula caused by a surgical thread left behind after an orthopedic hip operation performed sixteen years ago. Partial fistulectomy, extraction of the foreign material, and debridement procedures were performed. Few cases of such complex fistulas in ano due to foreign materials have been described in the literature. After careful history-taking, meticulous physical examination under general anesthesia should be done in order to deal with this rare type of fistula.

  8. Pectoralis major tendon repair: a biomechanical study of suture button versus transosseous suture techniques.

    Science.gov (United States)

    Thomas, William; Gheduzzi, Sabina; Packham, Iain

    2015-09-01

    Pectoralis major tendon avulsion injury benefits from surgical repair. The technique used and speed of rehabilitation in this demanding population remains subject to debate. We performed a biomechanical study comparing suture button (Pec Button™, Arthrex, Naples, FL) with a transosseous suture technique (FibreWire, Arthrex, Naples, FL). Freshly slaughtered porcine humeri were prepared to model a single transosseous suture or suture button repair. A static, tensile load to failure experiment and a cyclic, tensile load experiment to model standard (10,000 cycles) and accelerated rehabilitation (20,000 cycles) philosophies were tested. The mode of failure, yield and ultimate failure load, extension (clinical failure >10 mm) and the resistance to cyclic loading was measured. The mode of failure was suture fracture in all the static load experiments with 10/11 occurring as the suture passed through the button and 7/11 as the suture passed through the bone tunnels. There was a significant difference in yield load, favouring transosseous suture [p = 0.009, suture button (SB) 673.0 N (647.2-691.7 N), transosseous suture (TOS) 855.0 N (750.0-891.4 N)] and median extension, favouring suture button [p = 0.009, SB 8.8 mm (5.0-12.4 mm), TOS 15.2 mm (13.2-17.1 mm)]. 2/3 transosseous suture and 0/3 suture buttons failed before completing 20,000 cycles. The difference in mean number of cycles completed was non-significant. The difference in mean extension was 5.1 mm (SB 6.7 mm, TOS 11.7 mm). Both techniques show advantages. The difference in extension is likely to be more clinically relevant than load tolerated at failure, which is well above physiological levels. The findings do not support an accelerated rehabilitation model.

  9. Ab-interno scleral suture loop fixation with cow-hitch knot in posterior chamber intraocular lens decentration

    Science.gov (United States)

    Can, Ertuğrul; Koçak, Nurullah; Yücel, Özlem Eşki; Gül, Adem; Öztürk, Hilal Eser; Sayın, Osman

    2016-01-01

    Aim of Study: To describe a simplified ab-interno cow-hitch suture fixation technique for repositioning decentered posterior chamber intraocular lens (PC IOL). Materials and Methods: Two cases are presented with the surgical correction of decentered and subluxated IOL. Ab-interno scleral suture fixation technique with hitch-cow knot in the eye was performed with a ciliary sulcus guide instrument and 1 year follow-up was completed. Results: Both of the patients had well centered lenses postoperatively. Corrected distant and near visual acuities of the patients were improved. There was no significant postoperative complication. In the follow-up period of 1 year, no evidence of suture erosion was found. Conclusions: Ab-interno scleral suture loop fixation with hitch-cow knot in the eye was effective in repositioning decentered or subluxated PC IOLs with excellent postoperative centered lenses and visual outcomes. PMID:27050346

  10. Ab-interno scleral suture loop fixation with cow-hitch knot in posterior chamber intraocular lens decentration

    Directory of Open Access Journals (Sweden)

    Ertugrul Can

    2016-01-01

    Full Text Available Aim of Study: To describe a simplified ab-interno cow-hitch suture fixation technique for repositioning decentered posterior chamber intraocular lens (PC IOL. Materials and Methods: Two cases are presented with the surgical correction of decentered and subluxated IOL. Ab-interno scleral suture fixation technique with hitch-cow knot in the eye was performed with a ciliary sulcus guide instrument and 1 year follow-up was completed. Results: Both of the patients had well centered lenses postoperatively. Corrected distant and near visual acuities of the patients were improved. There was no significant postoperative complication. In the follow-up period of 1 year, no evidence of suture erosion was found. Conclusions: Ab-interno scleral suture loop fixation with hitch-cow knot in the eye was effective in repositioning decentered or subluxated PC IOLs with excellent postoperative centered lenses and visual outcomes.

  11. Reconstruction of displaced acromio-clavicular joint dislocations using a triple suture-cerclage: description of a safe and efficient surgical technique.

    Science.gov (United States)

    Sandmann, Gunther H; Martetschläger, Frank; Mey, Lisa; Kraus, Tobias M; Buchholz, Arne; Ahrens, Philipp; Stöckle, Ulrich; Freude, Thomas; Siebenlist, Sebastian

    2012-10-25

    In this retrospective study we investigated the clinical and radiological outcome after operative treatment of acute Rockwood III-V injuries of the AC-joint using two acromioclavicular (AC) cerclages and one coracoclavicular (CC) cerclage with resorbable sutures. Between 2007 and 2009 a total of 39 patients fit the inclusion criteria after operative treatment of acute AC joint dislocation. All patients underwent open reduction and anatomic reconstruction of the AC and CC-ligaments using PDS® sutures (Polydioxane, Ethicon, Norderstedt, Germany). Thirty-three patients could be investigated at a mean follow up of 32±9 months (range 24-56 months). The mean Constant score was 94.3±7.1 (range 73-100) with an age and gender correlated score of 104.2%±6.9 (88-123%). The DASH score (mean 3.46±6.6 points), the ASES score (94.6±9.7points) and the Visual Analogue Scale (mean 0.5±0,6) revealed a good to excellent clinical outcome. The difference in the coracoclavicular distance compared to the contralateral side was border of the clavicle was within 1 cm (ventral-dorsal direction) of the anterior rim of the acromion in 28 patients (85%). Re-dislocations occured in three patients (9%). Open AC joint reconstruction using AC and CC PDS cerclages provides good to excellent clinical results in the majority of cases. However, radiographically, the CC distance increased significantly at final follow up, but neither the amount of re-dislocation nor calcifications of the CC ligaments or osteoarthritis of the AC joint had significant influence on the outcome. Case series, Level IV.

  12. Reconstruction of displaced acromio-clavicular joint dislocations using a triple suture-cerclage: description of a safe and efficient surgical technique

    Directory of Open Access Journals (Sweden)

    Sandmann Gunther H

    2012-10-01

    Full Text Available Abstract Purpose In this retrospective study we investigated the clinical and radiological outcome after operative treatment of acute Rockwood III-V injuries of the AC-joint using two acromioclavicular (AC cerclages and one coracoclavicular (CC cerclage with resorbable sutures. Methods Between 2007 and 2009 a total of 39 patients fit the inclusion criteria after operative treatment of acute AC joint dislocation. All patients underwent open reduction and anatomic reconstruction of the AC and CC-ligaments using PDS® sutures (Polydioxane, Ethicon, Norderstedt, Germany. Thirty-three patients could be investigated at a mean follow up of 32±9 months (range 24–56 months. Results The mean Constant score was 94.3±7.1 (range 73–100 with an age and gender correlated score of 104.2%±6.9 (88-123%. The DASH score (mean 3.46±6.6 points, the ASES score (94.6±9.7points and the Visual Analogue Scale (mean 0.5±0,6 revealed a good to excellent clinical outcome. The difference in the coracoclavicular distance compared to the contralateral side was Conclusion Open AC joint reconstruction using AC and CC PDS cerclages provides good to excellent clinical results in the majority of cases. However, radiographically, the CC distance increased significantly at final follow up, but neither the amount of re-dislocation nor calcifications of the CC ligaments or osteoarthritis of the AC joint had significant influence on the outcome. Level of evidence Case series, Level IV

  13. Reacción tisular a materiales de sutura no absorbibles en piel de equinos Tissue reaction to nonabsorbable suture materials in horse skin

    Directory of Open Access Journals (Sweden)

    F Maldonado

    2006-01-01

    Full Text Available Se evaluó clínica e histológicamente el grado de reacción tisular frente a cuatro materiales de sutura no absorbibles (lino, nylon, caprolactam polimerizado y polipropileno, implantados en la piel de 8 equinos. Se determinó clínicamente el edema provocado y la ausencia o presencia de exudado a los 5 y 10 días de haber sido implantados los materiales de sutura, además al 10º día se realizó una biopsia para determinar histológicamente el grado de reacción tisular. Los resultados obtenidos mostraron que el lino causó un mayor edema al día 5, mientras que al día 10 el nylon y caprolactam provocaron un menor de edema. Con respecto a la presencia o ausencia de exudado, al día 5 la sutura de nylon fue la única que no presentó exudado en ninguno de los 8 ejemplares, sin embargo, al día 10, salvo un ejemplar que presentó exudado en todos los materiales, el nylon, caprolactam y polipropileno no presentaron exudado. En cuanto a la evaluación histológica tanto el nylon como el caprolactam mostraron menor grado de reacción tisular. En conclusión, el lino resultó tener el mayor grado de reacción tisular durante el presente estudio, y el nylon si bien es similar al caprolactam y polipropileno respecto a la reacción tisular, causó una menor cantidad de equinos con presencia de exudado que los otros materiales utilizados.The degree of tissue reaction of 4 nonabsorbable suture materials (linen, nylon, polymerized caprolactum and polypropylene implanted into health skin of 8 horses was clinically and histologically evaluated. Cutaneous oedema and absence or presence of the exudation were clinically evaluated 5 and 10 days following suture material implantation. Biopsies were taken to histologically evaluate tissue reaction at 10 days. The results obtained showed that linen caused more oedema by the 5th day, whereas the nylon and caprolactum had less oedema on the 10th day. With respect to the presence or absence of exudation, nylon was

  14. Avaliação anatomopatológica de cicatrizes uterinas de acordo com o tipo de sutura cirúrgica (modelo experimental Anatomopathological evaluation of uterine scars according to the type of surgical suture (experimental model

    Directory of Open Access Journals (Sweden)

    Rogério Gomes dos Reis Guidoni

    2007-12-01

    parâmetros macroscópicos e microscópicos avaliados.PURPOSE: to compare macro and microscopically, surgical uterine sutures in female rabbits, after caesarean section utilizing separate, continuous and continuous anchored suture stitches. METHODS: three New Zealand female rabbits in their first pregnancy were used. The caesarean section was carried out at the 26th day of gestation and three incisions were performed in each uterus. The hysterorrhaphy was performed with a 00 Vicryl® thread, and a different suture technique was employed for each incision. Total hysterectomy and adnexectomy were done at the 60th day post-delivery with the preservation of eventual adhesions for the evaluation of the surgical scars. The extent of scar retraction, amount of fibrin deposit and the suture integrity were evaluated through macroscopy. For the evaluation through microscopy, hematoxylin eosin technique was used for cellular colorimetry, and Masson's trichrom to evidence collagen. The statistical non-parametric Friedman's test was employed for the matching hypothesis, and Fisher's exact test to verify the homogeneity of the techniques (level of significance: 5%. RESULTS: a total of 18 scars were obtained (six scars per suture. The following mean values were obtained for the longitudinal (0.5/0.4/0.5, p=0.069 and transversal retraction degrees (0.3/0.4/0.3, p=0.143 respectively for separate, continuous and continuous anchored suture techniques. All sutures presented regular fibrin deposit, no adhesions and integral absorption of the stitches. The mean value of the blood vessels (158.5/139.3/172.1; p=0.293, fibroblasts (351.6/345.8/354.3; p=0.311 and of collagen percentage (44.0/45.5/48.5; p=0.422 were calculated through microscopy, respectively for separate, continuous and continuous anchored suture techniques. CONCLUSIONS: the type of hysterorrhaphy technique of caesarean section in female rabbits did not generate any significant statistical difference in the macroscopic and

  15. The enhanced healing of a high-risk, clean, sutured surgical incision by prophylactic negative pressure wound therapy as delivered by Prevena™ Customizable™: cosmetic and therapeutic results.

    Science.gov (United States)

    Scalise, Alessandro; Tartaglione, Caterina; Bolletta, Elisa; Calamita, Roberto; Nicoletti, Giovanni; Pierangeli, Marina; Grassetti, Luca; Di Benedetto, Giovanni

    2015-04-01

    According to the literature, incisional closure complications may range from postoperative surgical site infections, representing 17-22% of health care-associated infections, surgical wound dehiscence and formation of haematomas or seromas, and can lead to delayed or impaired incision healing. These kinds of situations are more common when wounds are closed under tension or in specific patient morbidities. Obesity, in particular, is associated with an impaired blood flow to tissues, predisposing the patient to increased risk of wound complications by various mechanisms. Incisional complications can become relevant economic burdens for health care systems because of an increase in the average length of hospital stay and readmissions, and additional medical and surgical procedures. Thus, a preventive therapy may have a critical role in the management of healing. Negative pressure wound therapy (NPWT) technology as delivered by Prevena™ Customizable™ (Kinetic Concepts Inc., San Antonio, TX) has recently been the focus of a new investigation, as a prophylactic measure to prevent complications via immediate postoperative application in high-risk, clean, closed surgical incisions. The authors present a 62-year-old class II obese female, who underwent bilateral inguinal dermolipectomy. Prophylactic NPWT as delivered by Prevena™ was performed successfully over surgical incisions. Cosmetic and therapeutic results are shown.

  16. Excised Abdominoplasty Material as a Systematic Plastic Surgical Training Model

    Directory of Open Access Journals (Sweden)

    M. Erol Demirseren

    2012-01-01

    Full Text Available Achieving a level of technical skill and confidence in surgical operations is the main goal of plastic surgical training. Operating rooms were accepted as the practical teaching venues of the traditional apprenticeship model. However, increased patient population, time, and ethical and legal considerations made preoperation room practical work a must for plastic surgical training. There are several plastic surgical teaching models and simulators which are very useful in preoperation room practical training and the evaluation of plastic surgery residents. The full thickness skin with its vascular network excised in abdominoplasty procedures is an easily obtainable real human tissue which could be used as a training model in plastic surgery.

  17. Nose tip refinement using interdomal suture in caucasian nose

    Directory of Open Access Journals (Sweden)

    Pasinato, Rogério

    2012-01-01

    Full Text Available Introduction: Refinement of the nose tip can be accomplished by a variety of techniques, but currently, the use of sutures in the nasal tip with conservative resection of the alar cartilage is the most frequently recommended approach. Objective: To classify the nasal tip and to demonstrate the interdomal suture applied to nasal tip refinement in the Caucasian nose, as well as to provide a simple and practical presentation of the surgical steps. Method: Development of surgical algorithm for nasal tip surgery: 1. Interdomal suture (double binding suture, 2. Interdomal suture with alar cartilage weakening (cross-hatching, 3. Interdomal suture with cephalic removal of the alar cartilage (McIndoe technique based on the nasal tip type classification. This classification assesses the interdomal distance (angle of domal divergence and intercrural distance, domal arch width, cartilage consistency, and skin type. Interdomal suture is performed through endonasal rhinoplasty by basic technique without delivery (Converse-Diamond technique under local anesthesia Conclusion: This classification is simple and facilitates the approach of surgical treatment of the nasal tip through interdomal suture, systematizing and standardizing surgical maneuvers for better refinement of the Caucasian nose.

  18. Postoperative washing of sutured wounds

    Directory of Open Access Journals (Sweden)

    Conrad Harrison

    2016-11-01

    Full Text Available A best evidence topic was written according to the structured protocol. The three part question addressed was: [In patients undergoing closure of surgical wounds with sutures] does [keeping the wound dry for the first 48 h after closure] [reduce the incidence of surgical site infections (SSIs]? 4 relevant papers were culled from the literature and appraised. The authors, date, country, population, study type, main outcomes, key results and study weaknesses were tabulated. Current NICE guidelines recommend cleaning surgical wounds with sterile saline only for the first 48 h following skin closure. We found no evidence that washing wounds with tap water during this period increases the incidence of SSIs compared to keeping them dry. Further randomised controlled trials will enable the construction of conclusive systematic reviews and meta-analyses.

  19. Surgical outcomes of mitomycin C combined with adjustable suture trabeculectomy for primary angle-closure glaucoma%丝裂霉素C联合可拆除缝线在小梁切除术中的临床应用

    Institute of Scientific and Technical Information of China (English)

    杨红艳

    2016-01-01

    目的:观察丝裂霉素 C 联合可拆除缝线在青光眼小梁切除术中的效果。方法对30例(35眼)青光眼患者进行丝裂霉素联合可拆除缝线的小梁切除术,术后随诊观察视力、眼压和滤过泡状况。结果手术后第1周眼压为(12.49±1.68) mmHg,第1个月眼压为(14.28±2.22)mmHg,第1年眼压为(17.29±2.87)mmHg 与手术前眼压相比较差异有统计学意义(P <0.05);术后1年功能型滤过泡35眼(82.86%)。结论丝裂霉素 C 联合可拆除缝线在小梁切除术中能有效降低眼压,减少术后并发症,提高手术成功率。%Objective To investigate the safety and efficacy of mitomycin C combined with adjustable suture trabeculectomyin treating primary angle-closure glaucoma.Methods This study included 30 patients(35 eyes)who underwent adjustable suture trabeculectomy combined with mitomycin C.Visual acuity,intraocular pressure and filtering blebs were measured.Results Mean postoperative intraoc-ular pressures were (12.49 ±1.68)mmHg at 1 week,(14.28 ±2.22)mmHg at 1 month and (17.29 ±2.87)mmHg at 1 year,re-spectively.There was significant difference between preoperation and postoperation(P <0.05).The rate of effective filtering bleb was 82.86% at 1 year.Conclusions Mitomycin C combined with adjustable suture trabeculectomy is a safe and effective surgical proce-dure to decrease intraocular pressure,reduce postoperative complications and raise success rate of the surgery.

  20. Bone Suture in Management of Mandibular Degloving Injury

    African Journals Online (AJOL)

    Journal of Surgical Technique and Case Report | Jan-Jun 2013 | Vol-5 | Issue-1. 35 ... bone suture technique. ... Center, Faculty of Dentistry, Mashhad University of Medical. Sciences ... After the administration of local anesthesia (lidocaine 2%.

  1. The use of suture anchors to repair the ruptured quadriceps tendon.

    Science.gov (United States)

    Bushnell, Brandon D; Whitener, George B; Rubright, James H; Creighton, R Alexander; Logel, Kevin J; Wood, Mark L

    2007-07-01

    Quadriceps tendon rupture is an incapacitating injury that usually requires surgical repair. Traditional repair methods involve transpatellar suture tunnels, but recent reports have introduced the idea of using suture anchors to repair the ruptured tendon. We present 5 cases of our technique of using suture anchors to repair the ruptured quadriceps tendon.

  2. A comparative study of outcome of the absorbable suture polydioxanone and nonabsorbable suture polypropylene in laparotomy wound closure

    Directory of Open Access Journals (Sweden)

    Kiran Shankar H.

    2016-06-01

    Full Text Available Background: Abdominal wound closure is one of the common operations for a general surgeon. Prevention of complications is important to reduce post-operative morbidity and mortality. Post-operative wound pain, wound infection, wound dehiscence, suture sinus formation; palpable knots and incisional hernia are the parameters are to be studied. Therefore, the present study was undertaken to compare polydioxanone and polypropylene suture material for abdominal fascial closure regarding morbidity in terms of post-operative wound complications. Methods: Patients admitted in the department of surgery, who undergo laparotomy operations, with midline abdominal incisions were included in the study. The recruited subjects were divided into Group-A, whom abdominal incisions are closed with non-absorbable suture material polypropylene and Group-B whom abdominal incisions are closed with absorbable suture material polydioxanone. Data was expressed as percentages. Results: The incidence of wound pain was observed in all the patients in both immediate and delayed post-operative period in the polypropylene suture material compared to polydioxanone. The incidence of wound infection was higher in polypropylene (24% compared to PDS (2%. There were 4% cases of wound dehiscence in the present study. The incidence of suture sinus formation was higher in the polypropylene suture material (9% compared to the polydioxanone suture material (2% in the delayed postoperative period. The incidence of palpable knots was higher in the polypropylene suture material (23% compared to the polydioxanone suture material. No cases of incisional hernia were reported with polydioxanone suture material. Conclusions: The overall morbidity from abdominal closure was considerably reduced in the Polydioxanone group. We encountered reduction in wound complications like burst abdomen, wound infection, wound pain, suture sinus formation, palpable knots and incisional hernia. Therefore

  3. A comparative study of the effect of suture-less and multiple suture techniques on inflammatory complications following third molar surgery.

    Science.gov (United States)

    Osunde, O D; Adebola, R A; Saheeb, B D

    2012-10-01

    The aim of this prospective randomized study was to evaluate the effect of not using sutures on postoperative pain, swelling and trismus after lower third molar surgery. 80 patients with impacted lower third molars were referred for surgical extraction (42 males; 38 females; aged 18-38 years). The patients were randomly divided into two equal groups (sutures n=40; suture-less n=40). In the experimental group, the flaps were replaced without suturing. The control group was selected using the same criteria and treated under the same surgical protocol as the experimental group, except that the flaps were apposed using multiple sutures. Pain, swelling and trismus were evaluated at 24 h, 48 h and 1 week postoperatively in both groups. The operation time was found to be significantly longer in the multiple sutures group (p0.05). There is less postoperative pain, swelling and trismus with the suture-less technique in third molar surgery.

  4. Insertion force in manual and robotic corneal suturing.

    Science.gov (United States)

    Yang, Yang; Xu, Cunliang; Deng, Shijing; Xiao, Jingjing

    2012-03-01

    Due to differences in corneal grafting microsurgery between manual and robotic suturing, new challenges have arisen in testing the insertion force and torque of corneal tissue acting on suturing needles in order to guarantee successful completion of surgical procedures. In order to measure the force during the insertion operation, from the needle entering the cornea through the entry point until the puncturing of the exit point along the circular trajectory, a force measurement system was established, including fresh porcine cornea, a corneal-suturing robot, a circular needle, a micro-forceps manipulator with a force transducer, a computer with a data acquisition board and a medical microscope. The force values in the needle coordinate frames were obtained on the basis of a sensor coordinate frame through D-H coordinate transformation, and an index is proposed here to evaluate the insertion performance. Experiments on both manual and robotic suturing were carried out for comparison. The scale and changes of the needle insertion force were obtained using two different suturing methods. The maximal tangent force in robotic suturing is a little larger than in manual suturing, and the maximal resultant force in robotic suturing is somewhat smaller. Although the difference is not very significant, robotic suturing performs in a more stable way. Moreover, the performance evaluation index M(dmax) (the maximum of square root of the quadratic sum of torque components M(OX) and M(OY)) in robotic suturing is much smaller than that in manual suturing. The force measurement system has been verified to be feasible through experimentation. Compared with conventional manual surgery, robotic suturing has some advantages: more stable suturing, smaller distortion torque and fewer invasions to the corneal tissue, showing that its application in minimally invasive surgery is practical. Copyright © 2011 John Wiley & Sons, Ltd.

  5. Proposal of a synthetic ethylene-vinyl acetate bench model for surgical foundations learning: suture training Modelo de bancada sintético de etileno vinil acetato para a aprendizagem das bases da cirurgia: treinamento de suturas

    Directory of Open Access Journals (Sweden)

    Érika Malheiros Bastos

    2011-04-01

    Full Text Available Due to ethical and legal aspects involved in the handling of cadavers and animals the synthetic simulators are an alternative for learning how to suture technique plus the practice of various procedures such as incision and surgical flap. In this context, this paper describes and propose the use of a synthetic model manufactured from plates of ethylene-vinyl acetate (EVA to teach primary surgical skills in medical students with no previous exposure to surgery. The model that provides the convenience of being easily reproducible, allowing the students in training can thus improve their skills before applying the technique in clinical practice.Devido aos aspectos éticos e legais envolvidos no manuseio de cadáveres e animais, os simuladores sintéticos surgem como alternativa para o ensino-aprendizagem de técnicas de sutura e simulação de procedimentos, como a confecção de incisões e retalhos cirúrgicos. Neste âmbito é proposto e descrito um modelo de bancada sintético confeccionado a partir de etileno vinil acetato (EVA para o ensino de habilidades cirúrgicas básicas, em estudantes de medicina sem exposição prévia a cirurgia. O modelo fornece a praticidade de ser reprodutível, barato e de fácil aquisição, possibilitando que o acadêmico em formação possa, portanto, aperfeiçoar suas habilidades antes de aplicar a técnica na prática clínica.

  6. Security and biomechanical strength of three end-pass configurations for the terminal end of intradermal closures performed with unidirectional barbed suture material in dogs.

    Science.gov (United States)

    Regier, Penny J; Smeak, Daniel D; McGilvray, Kirk C

    2016-12-01

    OBJECTIVE To compare security of continuous intradermal suture lines closed by use of barbed suture with 3 end-pass configurations or without an end-pass configuration. SAMPLE 40 full-thickness, 4-cm-long, parasagittal wounds in canine cadavers. PROCEDURES Each continuous intradermal closure was terminated with 1 of 3 end-pass techniques or without an end-pass configuration (control group). A servohydraulic machine applied tensile load perpendicular to the long axis of the suture line. A load-displacement curve was generated for each sample; maximum load, displacement, stiffness, mode of construct failure, and load at first suture slippage at termination (ie, terminal end of the suture line) were recorded. RESULTS Values for maximum load, displacement, and stiffness did not differ significantly among the 3 end-pass techniques, and load at first suture slippage at termination was not significantly different among the 4 groups. A 1-pass technique slipped in 5 of 9 samples; 3 of these 5 slips caused failure of wound closure. A 2-pass technique slipped in 3 of 9 samples, none of which caused failure of wound closure. Another 2-pass technique slipped in 4 of 10 samples; 2 of these 4 slips caused failure of wound closure. The control group had slippage in 10 of 10 samples; 9 of 10 slips caused failure of wound closure CONCLUSIONS AND CLINICAL RELEVANCE An end-pass anchor was necessary to terminate a continuous intradermal suture line, and all 3 end-pass anchor techniques were suitable to prevent wound disruption. The 2-pass technique for which none of the suture slippages caused wound closure failure provided the most reliable configuration.

  7. Biomechanical Dynamics of Cranial Sutures during Simulated Impulsive Loading

    Directory of Open Access Journals (Sweden)

    Z. Q. Zhang

    2015-01-01

    Full Text Available Background. Cranial sutures are deformable joints between the bones of the skull, bridged by collagen fibres. They function to hold the bones of the skull together while allowing for mechanical stress transmission and deformation. Objective. The aim of this study is to investigate how cranial suture morphology, suture material property, and the arrangement of sutural collagen fibres influence the dynamic responses of the suture and surrounding bone under impulsive loads. Methods. An idealized bone-suture-bone complex was analyzed using a two-dimensional finite element model. A uniform impulsive loading was applied to the complex. Outcome variables of von Mises stress and strain energy were evaluated to characterize the sutures’ biomechanical behavior. Results. Parametric studies revealed that the suture strain energy and the patterns of Mises stress in both the suture and surrounding bone were strongly dependent on the suture morphologies. Conclusions. It was concluded that the higher order hierarchical suture morphology, lower suture elastic modulus, and the better collagen fiber orientation must benefit the stress attenuation and energy absorption.

  8. Polypropylene suture--is it safe?

    Science.gov (United States)

    Calhoun, T R; Kitten, C M

    1986-07-01

    Polypropylene suture has steadily gained popularity for use in vascular and cardiac surgical procedures because of its long-term tensile strength and minimal tissue trauma. However, recently some questions have arisen concerning its safety. We recently had two cases of polypropylene fracture, one occurring early and the other late after operation. Comparison and collation of these two cases with other reports leads to the conclusion that polypropylene suture is safe in most situations, but care must be taken to avoid instrumentation trauma and kinking stresses at knots, which probably explain most of the reported cases of polypropylene failure. In addition, polypropylene probably should not be used in graft-to-graft anastomoses in which the continual sawing stresses of two rigid structures appears to lead to an excessive incidence of late suture fracture with resultant false aneurysm formation.

  9. Hypersensitivity to Suture Anchors

    Directory of Open Access Journals (Sweden)

    Masafumi Goto

    2013-01-01

    Full Text Available Hypersensitivity to suture anchor is extremely rare. Herein, we present a case in which hypersensitivity to suture anchor was strongly suspected. The right rotator cuff of a 50-year-old woman was repaired with a metal suture anchor. Three weeks after the surgery, she developed erythema around her face, trunk, and hands, accompanied by itching. Infection was unlikely because no abnormalities were detected by blood testing or by medical examination. Suspicious of a metallic allergy, a dermatologist performed a patch testing 6 months after the first surgery. The patient had negative reactions to tests for titanium, aluminum, and vanadium, which were the principal components of the suture anchor. The anchor was removed 7 months after the first surgery, and the erythema disappeared immediately. When allergic symptoms occur and persist after the use of a metal anchor, removal should be considered as a treatment option even if the patch test result is negative.

  10. The surgical experience of 48 cases of laparoscopic choledocholithotomy with primary suture%腹腔镜胆总管切开取石Ⅰ期缝合术48例临床体会

    Institute of Scientific and Technical Information of China (English)

    马陈; 朱挺; 陈晓岗

    2013-01-01

    Objective:To investigate the surgical experience and clinical value of laparoscopic choledocholithotomy with primary suture.Methods:The clinical data of patients suffered from choledocholithiasis from Jan.2010 to May 2012 were retrospectively analyzed.48 cases underwent laparoscopic choledocholithotomy with primary suture (observation group),69 cases underwent open choledocholithotomy T-tube drainage (open surgery T-tube group) and 52 cases underwent laparoscopic choledocholithotomy T-tube drainage (laparoscopic T-tube group).Results:All 48 cases in observation group were successfully operated.The operative time was between 90200 min,the average was (150 ±8.7) min;the blood loss was 30-50 ml,the average was (25 ±4.1) ml;the fart and ambulation appeared 1-2 days after operation.All patients were discharged from the hospital within 4-6 d,the average was (5 ± 0.3) d.No incision infection or bile leakage occurred.Compared with the other two groups,the patients in observation group showed faster recovery,less pain and cost,and shorter hospital stay.Conclusions:Laparoscopic choledocholithotomy with primary suture has more advantages with minimal invasion,quick recovery,little pain,short hospital stay.However,the surgeon and his assistants need more tacit understanding and longer learning curve.%目的:探讨腹腔镜胆总管切开取石Ⅰ期缝合术的手术方法与临床价值.方法:回顾分析2010年1月至2012年5月胆总管结石患者的临床资料,其中48例行腹腔镜胆总管切开取石Ⅰ期缝合术(观察组),69例行开腹胆总管切开取石+T管引流术(开腹T管组),52例行腹腔镜胆总管切开取石+T管引流术(腹腔镜T管组).对比分析3组手术结果.结果:观察组48例手术均获成功.手术时间90 ~ 200 min,平均(150±8.7) min;术中出血量30 ~ 50 ml,平均(25±4.1) ml.术后1~2 d排气并下床活动,4~6d出院,平均(5±0.3)d.无胆漏、切口感染等并发症发生.与其他两组相比,患者术后

  11. Comparison between stainless steel staples and silk sutures for primary closure of skin in patients undergoing neck dissection: A comparative clinical study

    Directory of Open Access Journals (Sweden)

    Abhishek Ghosh

    2015-01-01

    Full Text Available Introduction: Comparison between stainless steel staples and silk sutures for primary closure of skin in patients undergoing neck dissection, in context of rapid application, approximation of the skin edges, economy and aesthetics of the resultant scar. Aim: (1 To compare surgical stainless steel staples and silk sutures for primary wound closure, with respect to presence/absence of wound infection and dehiscence (2 To compare the resultant scar following the two different methods of the closure at 3 rd month postoperatively with the help of visual analog scale and analyze the result statistically Design: This study was designed to compare skin closure using staples and silk sutures in patients undergoing neck dissection, using both methods in one-half of the same wound; thus each wound affording its own control. Materials and Methods: The study was conducted on patients requiring collar line incision (high submandibular incision with or without a cephalad extension of midline lower lip split incision for surgical access, who presented to the Department of Oral and Maxillo-Facial Surgery. (1 Sample size: 10 (2 Study design: Prospective Comparative study (3 Study duration: One and half years (4 Surgical stainless steel staples: Proximate Plus MD 35 W, Ethicon Endo Surgery (5 Sutures: 3-0 Ethiprime NW 5003, Non-Absorbable Surgical Suture, Mersilk-90 cm, Ethicon, (16 mm 3/8 circle cutting needle. Conclusion: It wass concluded that there is no significant difference between the scars observed in the regions of incision which underwent primary closure by two different methods, that is surgical stainless steel staples and 3-0 Mersilk Sutures.

  12. Signaling mechanisms implicated in cranial sutures pathophysiology: Craniosynostosis

    Directory of Open Access Journals (Sweden)

    Maria A. Katsianou

    2016-12-01

    Full Text Available Normal extension and skull expansion is a synchronized process that prevails along the osteogenic intersections of the cranial sutures. Cranial sutures operate as bone growth sites allowing swift bone generation at the edges of the bone fronts while they remain patent. Premature fusion of one or more cranial sutures can trigger craniosynostosis, a birth defect characterized by dramatic manifestations in appearance and functional impairment. Up until today, surgical correction is the only restorative measure for craniosynostosis associated with considerable mortality. Clinical studies have identified several genes implicated in the pathogenesis of craniosynostosis syndromes with useful insights into the underlying molecular signaling events that determine suture fate. In this review, we exploit the intracellular signal transduction pathways implicated in suture pathobiology, in an attempt to identify key signaling molecules for therapeutic targeting.

  13. Strike-through of moist contamination by woven and nonwoven surgical materials.

    Science.gov (United States)

    Laufman, H; Eudy, W W; Vandernoot, A M; Harris, C A; Liu, D

    1975-06-01

    A test is described which correlates the stress of stretching surgical gown and drape material with moist bacterial strike-through. By application of this test to a number of woven and nonwoven surgical gown and drape materials, it was found that not all of these materials, either woven or nonwoven, are impermeable to moist contamination for equal periods of time. Nonwoven disposable materials now in use range from those which remain impermeable to moist bacterial permeation through all tests while some remain impermeable for limited periods of time, and others almost immediately permeable to moist bacterial penetration. The same situation holds for woven materials. Under conditions of our test, Quarpel treated Pima tight-woven cotton cloth was impermeable to moist bacterial strike-through, through up to 75 washing and sterilizing cyclings, while ordinary linen and untreated Pima cloth permitted bacterial permeation almost immediately. These results have significance in lengthy wet surgical operations.

  14. Usefulness of continuous suture using short-thread double-armed micro-suture for cerebral vascular anastomosis

    Directory of Open Access Journals (Sweden)

    Sei Haga

    2014-01-01

    Full Text Available Background: When microvascular anastomosis is performed in a deep, narrow operating field, securing space to throw knots is difficult. To simplify the procedure and avoid obstruction of the anastomosis, we use a continuous suturing with short-thread double-armed micro-suture. Methods: Sixty-four patients (38 cerebral revasculazation, 16 moyamoya disease, and 10 aneurysm surgery undergoing microvaucular anastomosis were included. During anastomosis, a continuous suture was placed with short-thread double-armed micro-suture. Results: During 64 microanastomosis procedures, 64 consecutive continuous sutures were performed with 1-year follow up. All patients showed patency of anastomosis with long-term follow up. Conclusions: This technique is especially useful for anastomosis in a deep, narrow surgical field, such as in superior cerebellar artery anastomosis.

  15. A technique for introducing looped sutures in flexor tendon repair

    Directory of Open Access Journals (Sweden)

    Kamath B

    2006-01-01

    Full Text Available Stronger flexor tendon repairs facilitate early active motion therapy protocols. Core sutures using looped suture material provide 1 ½ to twice the strength of Kessler′s technique (with four strand and six strand Tsuge technique respectively. The technique is well-described and uses preformed looped sutures (supramid. This is not available in many countries and we describe a technique whereby looped sutures can be introduced in flexor tendon repair by the use of 23 G hypodermic needle and conventional 4.0 or 5.0 sutures. This is an alternative when the custom made preformed sutures are not available. This can be practiced in zone 3 to zone 5 repairs. Technical difficulties limit its use in zone 2 repairs.

  16. How we do it:the Running-X suture technique

    Institute of Scientific and Technical Information of China (English)

    Nathaniel L Villanueva; Kyle Sanniec; Ronald Mancini

    2016-01-01

    There are a myriad of suture techniques available to close incisions of the brow and forehead, each with their own advantages and disadvantages. The ideal suture technique would provide excellent cosmetic results, offer expedient wound closure, optimize skin eversion and wound edge apposition, and provide excellent cosmetic results. The authors describe a new suture technique, the Running-X suture, a running horizontal mattress suture that has successfully been used by the senior author for many years to re-approximate surgical wounds of the brow and forehead in an expeditious and aesthetic manner.

  17. Blepharoptosis correction with buried suture method.

    Science.gov (United States)

    Park, Jang Woo; Kang, Moon Seok; Nam, Seung Min; Kim, Yong Bae

    2015-02-01

    Many surgical techniques have been developed to correct blepharoptosis, including the anterior levator resection or advancement, tarsoaponeurectomy, and Fasanella-Servat Müllerectomy. However, to minimize surgical scarring and reduce the postoperative recovery time, the procedure has been developed from a complete incision to a partial incision, which is appealing to patients. To aid the procedural development, this study describes a surgical technique in which the correction of blepharoptosis and a double eyelid fold operation are performed using a buried suture technique during the same operation. A retrospective review was conducted using the medical records and preoperative and postoperative photography of 121 patients who underwent simultaneous correction of blepharoptosis and had a double eyelid fold created between October 2010 and July 2011. All of the patients had mild (1-2 mm) or moderate (3-4 mm) bilateral blepharoptosis and excellent or good levator function (>8 mm). The average preoperative marginal reflex distance (MRD1) measured 1.174 (0.3) mm. No intraoperative complications occurred. The average postoperative MRD1 measured 3.968 (0.2) mm. There was statistical significance improvement between preoperative MRD1 and postoperative MRD1 (Pexposure keratopathy were noted. Blepharoptosis correction using the buried suture technique is an effective technique for young patients experiencing mild to moderate blepharoptosis who want to have the double eyelid fold operation using the buried suture technique.

  18. [Use of root-end filling materials in a surgical apical endodontic treatment in the Netherlands

    NARCIS (Netherlands)

    Bronkhorst, M.A.; Berge, S.J.; Damme, P.A. van; Borstlap, W.A.; Merkx, M.A.W.

    2008-01-01

    The material to be used for closing the root canal when carrying out a retrograde surgical apical endodontic treatment continues to be a subject of discussion. The aim of the present study was to inventory which materials are being used for this purpose at this moment by Dutch O&MF surgeons. All pra

  19. Suture anchor repair of quadriceps tendon rupture after total knee arthroplasty.

    Science.gov (United States)

    Kim, Tae Won B; Kamath, Atul F; Israelite, Craig L

    2011-08-01

    Disruption of the extensor mechanism after total knee arthroplasty (TKA) is a devastating complication, usually requiring surgical repair. Although suture anchor fixation is well described for repair of the ruptured native knee quadriceps tendon, no study has discussed the use of suture anchors in quadriceps repair after TKA. We present an illustrative case of successful suture anchor fixation of the quadriceps mechanism after TKA. The procedure has been performed in a total of 3 patients. A surgical technique and brief review of the literature follows. Suture anchor fixation of the quadriceps tendon is a viable option in the setting of rupture after TKA.

  20. Laparoscopic sacral suture hysteropexy for uterine prolapse.

    Science.gov (United States)

    Krause, Hannah G; Goh, Judith T W; Sloane, Kate; Higgs, Peta; Carey, Marcus P

    2006-06-01

    This study aims to describe and review a new method of uterine conservation in pelvic reconstruction for women with uterine prolapse. This is a prospective study of women who have undergone laparoscopic sacral suture hysteropexy. Structured questions, visual analogue patient satisfaction score (VAS), and vaginal examination were undertaken. Follow-up was performed by non-surgical reviewers. From July 2001 until August 2003, a total of 81 women underwent laparoscopic sacral suture hysteropexy for uterine prolapse. At a mean of 20.3 months follow-up, 76 women (93.8%) were available for questioning and 57 (70.3%) attended for examination. Sixty-five women (87.8%) had no symptoms of pelvic floor prolapse, 54 women (94.7%) had no objective evidence of uterine prolapse, and 61 women (82.4%) were satisfied with their surgery (VAS > or = 80%). Laparoscopic sacral suture hysteropexy attaches the posterior cervix to the sacral promontory via the right uterosacral ligament. Follow-up data of laparoscopic sacral suture hysteropexy indicate it to be an effective method in the management of uterine prolapse.

  1. Effects of suture position on left ventricular fluid mechanics under mitral valve edge-to-edge repair.

    Science.gov (United States)

    Du, Dongxing; Jiang, Song; Wang, Ze; Hu, Yingying; He, Zhaoming

    2014-01-01

    Mitral valve (MV) edge-to-edge repair (ETER) is a surgical procedure for the correction of mitral valve regurgitation by suturing the free edge of the leaflets. The leaflets are often sutured at three different positions: central, lateral and commissural portions. To study the effects of position of suture on left ventricular (LV) fluid mechanics under mitral valve ETER, a parametric model of MV-LV system during diastole was developed. The distribution and development of vortex and atrio-ventricular pressure under different suture position were investigated. Results show that the MV sutured at central and lateral in ETER creates two vortex rings around two jets, compared with single vortex ring around one jet of the MV sutured at commissure. Smaller total orifices lead to a higher pressure difference across the atrio-ventricular leaflets in diastole. The central suture generates smaller wall shear stresses than the lateral suture, while the commissural suture generated the minimum wall shear stresses in ETER.

  2. Pterion: An anatomical variation and surgical landmark

    Directory of Open Access Journals (Sweden)

    Prashant E Natekar

    2011-01-01

    Full Text Available Introduction : The frontal and the parietal bones superiorly and the greater wing of the sphenoid and the squamous temporal inferiorly of one side meet at an H-shaped sutural junction termed the pterion. This is an important anatomical and anthropological landmark as it overlies both the anterior branch of middle meningeal artery and the lateral fissure of the cerebral hemisphere. The knowledge of sutural joints between frontal, parietal, sphenoid and temporal bones at pterion is clinically, radiologically and surgically important during surgical interventions involving burr hole surgeries. Materials and Methods : Study performed on 150 dry temporal bones. The pterion, and its sutural articulations with frontal, parietal, sphenoid and temporal bones and also anatomical variations, if any, were studied. Results : Four types of pterion, i.e. sphenoparietal, frontotemporal, stellate and epipteric, were observed. Conclusions : The knowledge of the variations of pterion and its surgical anatomy, in Indian population are important for surgeons operating in the fieldThe present study will also contribute additional information of skull bone fractures in infancy and early childhood, which may be associated with large intersutural bones giving false appearance of fracture radiologically and also during surgical interventions involving burr hole surgeries, as their extensions may lead to continuation of fracture lines.

  3. An easier method for performing a pancreaticojejunostomy for the soft pancreas using a fast-absorbable suture

    Institute of Scientific and Technical Information of China (English)

    Kenichi Hakamada; Shunji Narumi; Yoshikazu Toyoki; Masaki Nara; Kenosuke Ishido; Takuya Miura; Norihito; Mutsuo Sasaki

    2008-01-01

    AIM:To clarify the usefulness of a new method for performing a pancreaticojejunostomy by using a fastabsorbable suture material irradiated polyglactin 910,and a temporary stent tube for a narrow pancreatic duct with a soft pancreatic texture.METHODS:Among 63 consecutive patients with soft pancreas undergoing a pancreaticoduodenectomy from 2003 to 2006,35 patients were treated with a new reconstructive method.Briefly,after the pancreatic transaction,a stent tube was inserted into the lumen of the pancreatic duct and ligated with it by a fastabsorbable suture.Another tip of the stent tube was introduced into the intestinal lumen at the jejunal limb,where a purse-string suture was made by another fast-absorbable suture to roughly fix the tube.The pancreaticojejunostomy was completed by ligating two fast-absorbable sutures to approximate the ductal end and the jejunal mucosa,and by adding a rough anastomosis between the pancreatic parenchyma and the seromuscular layer of the jejunum.The initial surgical results with this method were retrospectively compared with those of the 28 patients treated with conventional duct-to-mucosa anastomosis.RESULTS:The incidences of postoperative morbidity including pancreatic fistula were comparable between the two groups (new;3%-17% vs conventional;7%-14% according to the definitions).There was no mortality and re-admission.Late complications were also rarely seen.CONCLUSION:A pancreaticojejunostomy using an irradiated polyglactin 910 suture material and a temporary stent is easy to perform and is feasible even in cases with a narrow pancreatic duct and a normal soft pancreas.

  4. Scalp Incision Suturation Technology Improvement%头皮切口缝合技术的改良进展

    Institute of Scientific and Technical Information of China (English)

    周全

    2013-01-01

    Traditional scalp suture only closes the incision,which has high incidence of complications and poor cosmetic effect. So constant improvement of surgical suture method to improve wound healing and aesthetic effects is needed. With the emergence of new suture materials and constantly improving suture methods, the healing of the scalp incision has been significantly improved. The advantages of intradermal suture are the-neat match,small scar,and good apperance;aU subcutaneous and skin sutures adopt absorbable materials , which avoids long term thread end exposure. The method has both reduced the suffering of the patients, and comforted the patient's psychological needs, which is in line with the physiological,psychological,and social model.%传统的头皮缝合方法仅能达到闭合切口的作用,不但并发症高,而且切口美容效果差.为提高切口的愈合率和美观效果,需要不断地改良手术缝合方法.随着新的缝合材料的出现,缝合方法不断改良,头皮切口的愈合效果得到了明显的改善.皮内缝合法的优点是切口对合整齐,瘢痕小,美观;所有皮下及皮内缝线均采用可吸收线、免拆线,也避免了切口远期线头外露.既减轻了患者的痛苦,又安慰了患者的心理,符合生理-心理-社会模式.

  5. Analysis of the readability of patient education materials from surgical subspecialties.

    Science.gov (United States)

    Hansberry, David R; Agarwal, Nitin; Shah, Ravi; Schmitt, Paul J; Baredes, Soly; Setzen, Michael; Carmel, Peter W; Prestigiacomo, Charles J; Liu, James K; Eloy, Jean Anderson

    2014-02-01

    Patients are increasingly using the Internet as a source of information on medical conditions. Because the average American adult reads at a 7th- to 8th-grade level, the National Institutes of Health recommend that patient education material be written between a 4th- and 6th-grade level. In this study, we assess and compare the readability of patient education materials on major surgical subspecialty Web sites relative to otolaryngology. Descriptive and correlational design. Patient education materials from 14 major surgical subspecialty Web sites (American Society of Colon and Rectal Surgeons, American Association of Endocrine Surgeons, American Society of General Surgeons, American Society for Metabolic and Bariatric Surgery, American Association of Neurological Surgeons, American Congress of Obstetricians and Gynecologists, American Academy of Ophthalmology, American Academy of Orthopedic Surgeons, American Academy of Otolaryngology-Head and Neck Surgery, American Pediatric Surgical Association, American Society of Plastic Surgeons, Society for Thoracic Surgeons, and American Urological Association) were downloaded and assessed for their level of readability using 10 widely accepted readability scales. The readability level of patient education material from all surgical subspecialties was uniformly too high. Average readability levels across all subspecialties ranged from the 10th- to 15th-grade level. Otolaryngology and other surgical subspecialties Web sites have patient education material written at an education level that the average American may not be able to understand. To reach a broader population of patients, it might be necessary to rewrite patient education material at a more appropriate level. N/A. © 2013 The American Laryngological, Rhinological and Otological Society, Inc.

  6. SKIN STAPLED OR SUTURED: A COMPARATIVE STUDY

    Directory of Open Access Journals (Sweden)

    Veerendra Kumar

    2015-01-01

    Full Text Available BACKGROUND: The choice of wound closure after a surgical procedure has been a surgeon’s dilemma . The concerns have been as to how fast , uneventful , less painful , with minimal complications and comfortable will the patient’s recovery be. A well - known technology is surgical staples which are easier to use , less time consuming and a needle free method o f wound closure. OBJECTIVE: To compare skin staples with non - absorbable skin suture for skin closure in surgical laparotomy procedures for the following character : wound infection , dehiscence , cosmesis and postoperative pain . METHODS: This is a comparative study conducted on 100 patients divided in two groups randomly at Bapuji Hospital for cases undergoing surgical laparotomy procedures. Skin closure was done with 2 - 0 polyamide skin sutures in one group and skin closure was achieved with skin staples in th e other group. The outcome of wound was assessed on 3rd , 5th and 7th postoperative days using ASEPSIS score. Wound cosmesis was assessed on the 7th postoperative day and followed up at 1st month and 3rd month , using modified Hollander cosmesis scale. Postoperative pain was assessed using the visual analogue scale on the 1st , 3rd and 7th postoperative days. RESULTS : The mean wound ASPESIS scores on day 3 for skin staples and sutured group was 0.28 and 0.36 (p=0.7 respectively. The score on day 5 for staples and sutured group was 0.12 and 0.28 (p=0.4 respectively. The results in both the groups were the same , 0.08 on day 7(p=0. Wound cosmesis mean score assessment on day 7 for skin staples suturing group was 5.84 and 5.68 respectively (p=0.3. The mean score for cosmesis assessment at 1 month , and 3 rd month for skin staples and suturing group was 5.92 and 5.68 (p=0.1 and was 6.00 and 5.92 (p=0.36 respectively which was not satistically significant . The visual analogue scale score for postopera tive pain on 1st day , 3 rd and 7 th day for skin staples and suturing group 54

  7. MonoMax Suture: A New Long-Term Absorbable Monofilament Suture Made from Poly-4-Hydroxybutyrate

    Directory of Open Access Journals (Sweden)

    Erich K. Odermatt

    2012-01-01

    Full Text Available A long-term absorbable monofilament suture was developed using poly-4-hydroxybutyrate (P4HB made from a biosynthetically produced homopolymer of the natural metabolite 4-hydroxybutyrate. The suture, called MonoMax, has prolonged strength retention. At 12 weeks, a size 3-0 MonoMax suture retains approximately 50% of its initial tensile strength in vivo and is substantially degraded in one year with minimal tissue reaction. In contrast, PDS II monofilament suture (Ethicon, Inc., Somerville, NJ has no residual strength in vivo after 12 weeks. In vivo, the MonoMax suture is hydrolyzed primarily by bulk hydrolysis, and is then degraded via the Krebs cycle. MonoMax is substantially more compliant than other monofilament sutures, and incorporates an element of elasticity. Its tensile modulus of 0.48 GPa is approximately one-third of the value of the PDS II fiber providing an exceptionally flexible and pliable fiber with excellent knot strength and security. These features are further enhanced by the fiber's elasticity, which also improves knot security and may help prevent wound dehiscence. Because of its performance advantages, this suture may find clinical utility in applications where prolonged strength retention, and greater flexibility are required, particularly in procedures like abdominal wall closure where wound dehiscence is still a significant post-surgical complication.

  8. Interrupted or continuous-intradermal suturing? Statistical analysis of postoperative scars

    Directory of Open Access Journals (Sweden)

    Elif Sarı

    2014-12-01

    Full Text Available Background and Design: Postoperative scar development is an important problem for patients treated in plastic surgery clinics. Most patients think that continuous intradermal suturing is superior to interrupted suturing because they assume that it creates less scarring. We evaluated scars that form following intradermal and interrupted suturing. This article presents our controlled study that objectively compared the scars on patients' faces using a wound evaluation scale. Materials and Methods: Thirty-five patients, who had undergone operations on the bilateral cheeks, were included in this study. Thirty patients were female; five patients were male. Their mean age was 40.05 years. The average scar evaluation time after surgery was 9.05 months. Elliptical excisions were made on the lesions under local anesthesia. The incisions on the right cheeks were sutured with 6/0 monofilament nonabsorbable sutures using the continuous intradermal suturing technique. The left cheek incisions were sutured with same sutures using the interrupted suturing method. Results: The patients were evaluated 7–11 months after operation (mean: 9.05 months using the Stony Brook Scar Evaluation Scale. A Related Samples T-test was used for statistical evaluation of the differences between the suturing techniques. No significant differences were noted in scar formation between the two suturing methods (p>0.05. Conclusion: We found no differences in scar formation between the two frequently used suturing techniques studied here. We believe that the suturing technique is a less important determinant of scar formation than are other factors.

  9. Cranial suture morphology and its relationship to diet in Cebus.

    Science.gov (United States)

    Byron, Craig D

    2009-12-01

    Cranial sutures are complex morphological structures. Four Cebus species (C. albifrons, C. apella, C. capucinus, C. olivaceus) are used here to test the hypothesis that sagittal suture complexity is enhanced in animals that eat materially challenging foods. These primates are ideal for such comparative studies because they are closely related and some are known to exhibit differences in the material properties of the foods they ingest and masticate. Specifically, Cebus apella is notable among members of this genus for ingesting food items of high toughness as well as consistently demonstrating a relatively robust cranial morphology. Consistent with previous studies, C. apella demonstrates significantly more robust mandibular and temporal fossa morphology. Also, C. apella possesses sagittal sutures that are more complex than congenerics. These data are used to support the hypothesis that cranial suture complexity is increased in response to consuming diets with more obdurate material properties. One interpretation of this hypothesis is that, compared to non-apelloids, total strain in the apelloid cranial suture connective tissue environment is elevated due to increased jaw muscle activity by increases in either force magnitudes or the number of chewing events. It is argued that greater masticatory function enhances the growth and modeling of cranial suture interdigitation. These data show that cranial suture complexity is one more hard tissue feature from the skull that might be used to inform hypotheses of dietary functional morphology.

  10. 玻璃体腔内套结法固定脱位人工晶状体的效果%The surgical effects of fixating the luxated intraocular lens in the vitreous cavity with cow hitch knots suturing technique

    Institute of Scientific and Technical Information of China (English)

    邹玉平; 余惠英; 张楚; 邹秀兰; 丁小燕; 唐仕波; 林振德

    2012-01-01

    Objective Using intraocular cow hitch knots to fix the luxated intraocular lens (IOL) in the vitreous cavity without IOL extraction,and observe the effect of the surgery.Methods It was a retrospective case series study.A three-port vitrectomy were using to suture the IOL which were dislocated in the vitreous cavity.After the vitrectomy,intraocular cow hitch knots were used to fixate the IOL haptics in 12 patients with a luxated IOL in the vitreous cavity.Patients were followed up for 6~61 months,visual acuity and surgical complications associated with the procedure were evaluated after the surgery.Results The postoperative best-corrected visual acuity (BCVA) of 12 patients were 2/100 to 20/20.In all 12 cases,the IOL fixated stably and remained well positioned during the follow-up.Postoperative complications included corneal edema in all eyes,ocular hypotension in 5 eyes,temporary ocular hypertension in 2 eyes,and fibrin exudates in the anterior chamber in 1 eye.Retinal detachment was observed in 2 cases,which were reattached by scleral buckling.Conclusion Fixating the IOL in vitreous cavity directly after vitrectomy using intraocular cow hitch knots enables secure fixation of the luxated IOL in the vitreous without extracting it.This technique is the simplest and most effective method for management of IOL dislocation into vitreous cavity.%目的 采用玻璃体腔内套结法处理脱位至后玻璃体腔内的后房型人工晶状体(IOL),并对手术效果进行观察.方法 回顾性病例研究.对12例IOL脱位至玻璃体腔的患者行玻璃体切除术后玻璃体腔内复位固定后房型IOL,术后随访6~61个月,观察手术前、后患者的视力情况和并发症.结果 12例患者术后最佳矫正视力为0.02~1.0,IOL位置在随访期间无改变.所有病例术后均有不同程度角膜水肿,5例早期眼压偏低,2例出现一过性眼压增高,1例出现前房纤维素性渗出.2例术后发生视网膜脱离,行巩膜外

  11. [Use of root-end filling materials in a surgical apical endodontic treatment in the Netherlands

    OpenAIRE

    Bronkhorst, M.A.; Berge, S.J.; van Damme, P. A.; Borstlap, W.A.; Merkx, M.A.W.

    2008-01-01

    The material to be used for closing the root canal when carrying out a retrograde surgical apical endodontic treatment continues to be a subject of discussion. The aim of the present study was to inventory which materials are being used for this purpose at this moment by Dutch O&MF surgeons. All practicing Dutch OM&F surgeons (n = 195) were sent a questionnaire. The response rate was 77%. The results showed that at this moment intermediate restoration material (IRM) is the retrograde filling ...

  12. Análise da resistência de fios cirúrgicos utilizados no reparo do manguito rotador Strength analysis of surgical sutures used to repair the rotator cuff

    Directory of Open Access Journals (Sweden)

    Marcus Valladares Guimarães

    2008-07-01

    Full Text Available OBJETIVO: Analisar a resistência final suportada por dois tipos de fio e pela interface âncora-fio em três diferentes implantes tipo âncora submetidos à tração contínua, com o propósito de indicar o mais apropriado para sutura de estruturas como o manguito rotador do ombro. MÉTODOS: Os testes foram feitos em três grupos: grupo 1 - parafuso âncora de titânio com fio Ethibond® #2; grupo 2 - parafuso âncora de titânio com fio Fiber Wire® #2; e grupo 3 - parafuso âncora de titânio 5,0mm Corkscrew®. RESULTADOS: No grupo 1, a carga máxima média até a soltura foi de 124,5 newtons (N, sendo a mínima de 105N e a máxima de 180N, com variação de 75N entre os dois extremos e desvio-padrão de 23,03N. No grupo 2, a carga máxima média até a soltura foi de 298N, mínima de 230N, máxima de 375N, com variação de 145N e desvio-padrão de 44,73N. No grupo 3, foi obtida a maior carga máxima média, sendo esta de 272N, a mínima de 205N e a máxima de 340N, com variação de 135N. A análise estatística demonstrou diferença significativa entre as médias de cargas resistidas entre os grupos 1 x 2 e 1 x 3 (p OBJECTIVE: To analyze the final strength withstood by two types of suture threads and by the anchor-suture interface in three different anchor implants submitted to continuous traction for the purpose of choosing the most appropriate to suture structures such as the shoulder rotator cuff. METHOD: Tests were performed in three groups: Group 1 - titanium anchor screw with Ethibond® #2 suture, Group 2 - titanium anchor screw with Fiber Wire® #2 suture, and Group 3 - Corkscrew® 5.0 mm anchor screw. RESULTS: In Group 1, mean maximum load till loosening was 124.5 124,5 Newtons (N, the minimum load was 105 N, and the maximum load was 180 N, with a range of 75 N between the two extremes, and standard deviation of 23.03 N. In Group 2, the mean maximum load till loosening was 298 N, the minimum load was 230 N, the maximum load was 375

  13. Gene transfer during surgical procedures with molecular surgical suture

    Directory of Open Access Journals (Sweden)

    Dan Huang

    2009-06-01

    Full Text Available Over the last decades, there has been an explosion of interest in plasmid DNA for gene therapy with reports of their efficacy in the fight against cancer, vascular diseases, and inherited diseases caused by specific gene defects (Srivastava, 2003. DNA plasmids present several advantages over the use of recombinant viruses concerning their production and safety issues. Plasmid DNA vectors can be constructed easily and economically, and they are free of size constraints imposed by viral packaging, obviating the need for an infectious vector and lessening the likelihood of toxicity and immunogenicity (Davis, 1993. Plasmids have a relative low cost, long shelf life and allow repetitive administration of the therapeutic gene without generating an immune response against the delivery vector (Donnelly, 2003. Finally, plasmids can be injected directly into tissues, such as heart (Sarkar, 2002, muscle (Neumeister, 2001, Dan, 2000 and tumors (De Marco, 2003, Sasaki, 2002.

  14. Performance of antegrade suture passers according to tendon thickness

    Directory of Open Access Journals (Sweden)

    Myung-Sun Kim

    2015-01-01

    Full Text Available Purpose: To determine the effect of tendon thickness on the needle penetration ability of four different designs of antegrade suture passers. Materials and Methods: Four antegrade suture passers were tested: (a ExpresSew II (Depuy Mitek Inc., Raynham, MA, (b Arthrex Scorpion (Arthrex, Naples, FL, (c Concept (Linvatec Corp, Largo, FL, and (d ElitePass (Smith and Nephew Endoscopy, Andover, MA. Bovine tendons were divided into five thickness groups: 3, 5, 7, 9 and 11 mm. At each tendon thickness, we performed 15 trials with the suture loaded and 15 unloaded per device. Successful needle penetration was recorded, and in case of success, the exit point of the needle was noted in relation to the superior arm of the grasping component. Results: All tested suture passing devices successfully penetrated tendon thicknesses of 3 and 5 mm. With the suture loaded, one device (Concept only successfully penetrated 7 mm group tendons in 3/15 (20% trials. Success rates at 9 mm with the suture loaded were 40% in ExpresSew II, 53% in Arthrex Scorpion, 0% in Concept and 53% in ElitePass. Among successful passages with a loaded suture in the 7 and 9 mm-groups, about 20-50% of passages were oblique, and the needle came out distal to the superior arm of grasping the component. No trial with any device succeeded with 11 mm tendons in the suture loading condition. Conclusion: Using an antegrade suture passer during arthroscopic rotator cuff repair should be carefully considered when the torn end of the tendon is thicker than about 7-9 mm due to potential failure of needle penetration and/or too oblique a suture passage. Level of Evidence: Controlled laboratory study.

  15. Performance of antegrade suture passers according to tendon thickness

    Science.gov (United States)

    Kim, Myung-Sun; Kim, Dong Whan; Choi, Young Eun; Bachman, Larry; Kim, Sae Hoon

    2015-01-01

    Purpose: To determine the effect of tendon thickness on the needle penetration ability of four different designs of antegrade suture passers. Materials and Methods: Four antegrade suture passers were tested: (a) ExpresSew II (Depuy Mitek Inc., Raynham, MA), (b) Arthrex Scorpion (Arthrex, Naples, FL), (c) Concept (Linvatec Corp, Largo, FL), and (d) ElitePass (Smith and Nephew Endoscopy, Andover, MA). Bovine tendons were divided into five thickness groups: 3, 5, 7, 9 and 11 mm. At each tendon thickness, we performed 15 trials with the suture loaded and 15 unloaded per device. Successful needle penetration was recorded, and in case of success, the exit point of the needle was noted in relation to the superior arm of the grasping component. Results: All tested suture passing devices successfully penetrated tendon thicknesses of 3 and 5 mm. With the suture loaded, one device (Concept) only successfully penetrated 7 mm group tendons in 3/15 (20%) trials. Success rates at 9 mm with the suture loaded were 40% in ExpresSew II, 53% in Arthrex Scorpion, 0% in Concept and 53% in ElitePass. Among successful passages with a loaded suture in the 7 and 9 mm-groups, about 20-50% of passages were oblique, and the needle came out distal to the superior arm of grasping the component. No trial with any device succeeded with 11 mm tendons in the suture loading condition. Conclusion: Using an antegrade suture passer during arthroscopic rotator cuff repair should be carefully considered when the torn end of the tendon is thicker than about 7-9 mm due to potential failure of needle penetration and/or too oblique a suture passage. Level of Evidence: Controlled laboratory study. PMID:25937714

  16. Penile torsion correction by diagonal corporal plication sutures

    Directory of Open Access Journals (Sweden)

    Brent W. Snow

    2009-02-01

    Full Text Available Penile torsion is commonly encountered. It can be caused by skin and dartos adherence or Buck’s fascia attachments. The authors suggest a new surgical approach to solve both problems. If Buck’s fascia involvement is demonstrated by artificial erection then a new diagonal corporal plication suture is described to effectively solve this problem.

  17. Longitudinal parallel compression suture to control postopartum hemorrhage due to placenta previa and accrete

    Directory of Open Access Journals (Sweden)

    Guang-Tai Li

    2016-04-01

    Conclusion: Longitudinal parallel compression suture is a safe, easy, effective, practical, and conservative surgical technique to stop intractable PPH from the lower uterine segment, particularly in women who have a cesarean scar and placenta previa/accreta.

  18. Development and characterization of antibacterial braided polyamide suture coated with chitosan-citric acid biopolymer.

    Science.gov (United States)

    Debbabi, Faten; Gargoubi, Sondes; Hadj Ayed, Mohamed Adnene; Abdessalem, Saber Ben

    2017-09-01

    Braided polyamide sutures are frequently used in dermatologic surgery for wound closure. However, braided sutures promote bacteria proliferation. In order to prevent wound complications due to this effect, antibacterial sutures should be used. The main objective of this study is the development of new non-absorbable antibacterial polyamide braided suture. This paper suggests new coating process that leads to obtain suture uniformly covered by antibacterial film enclosing chitosan, which is known for its antibacterial benefit. Mechanical properties and surface morphology of developed sutures were investigated by using mechanical tests. Sutures surfaces were also examined by scanning electron microscope, to perceive spreading of coating product on suture surface. In order to identify potential reactions between chemical compounds present in coating solution and suture material, sutures were analyzed by ATR-IF spectroscopy. It has been demonstrated that many eventual bonds between compounds present in coating solutions and polyamide macromolecular chain may occur. The existence of these bonds implies the fixation of biopolymer coating on suture surface. It has been demonstrated that uniform surface may be obtained by progressively applying coating solution containing little amount of chitosan on suture surface. We have also found that developed coating process has not affected mechanical properties of suture, which still meet United States Pharmacopeia requirement. Finally, antibacterial effects against four colonies, very widespread in hospitals, were studied. Prominent antibacterial effects of braided polyamide suture against two gram-positive ( S Aureus, S epidermidis) and two gram-negative ( E coli and P aeruginosa) colonies are presented. Optimal result of best properties is obtained by applying three layers of biopolymer coating comprising 1% chitosan and 10% citric acid. The new developed suture coating process appears as a promising method for obtaining

  19. [Use of root-end filling materials in a surgical apical endodontic treatment in the Netherlands].

    Science.gov (United States)

    Bronkhorst, M A; Bergé, S J; Van Damme, Ph A; Borstlap, W A; Merkx, M A W

    2008-08-01

    The material to be used for closing the root canal when carrying out a retrograde surgical apical endodontic treatment continues to be a subject of discussion. The aim of the present study was to inventory which materials are being used for this purpose at this moment by Dutch O&MF surgeons. All practicing Dutch OM&F surgeons (n = 195) were sent a questionnaire. The response rate was 77%. The results showed that at this moment intermediate restoration material (IRM) is the retrograde filling material most widely used by the Dutch O&MF surgeons (47.6%) in cases of surgical apical endodontic treatment. Amalgam, with 35%, was second, especially due to its plasticity and convenience. The choice of material is just as often determined by tradition, personal preference, individual experience or scientific results. There seems to be no relationship between the dental surgeon's number of years of experience and the type of retro grade filling material which he or she uses.

  20. [Application and development of suture-dragging therapy for anal fistula].

    Science.gov (United States)

    Wang, Chen; Yao, Yibo; Dong, Qingjun; Liang, Hongtao; Guo, Xiutian; Cao, Yongqing; Lu, Jingen

    2015-12-01

    Traditional Chinese surgical treatment "suture-dragging" therapy is based on medical thread therapy and tight seton drainage in combination of minimal invasive surgical principle. It can preserve the integrity of anal sphincter musculature involved in fistulous tract or abscess and maintain anal function. This article not only describes in detail about the operation points and mechanisms of "suture-dragging" therapy of anorectal fistula, but also reviews the application and modification of anorectal disease.

  1. Midwives conducting perineal repair: The Danish Suture Trial

    DEFF Research Database (Denmark)

    Kindberg, Sara

    2007-01-01

    Midwives conducting perineal repair: The Danish Suture Trial.     Background Suture techniques and materials for repair of 2nd degree perineal lacerations and episiotomies have been tested in several clinical trials. Danish midwives and obstetricians have developed a new, simple and time-efficien......Midwives conducting perineal repair: The Danish Suture Trial.     Background Suture techniques and materials for repair of 2nd degree perineal lacerations and episiotomies have been tested in several clinical trials. Danish midwives and obstetricians have developed a new, simple and time...... assessed day 1-2 and 10 post partum. Secondary outcomes: patient satisfaction with wound healing, need for secondary repair, superficial pain during intercourse.   Data management: Double entry of all data and intention-to-treat analysis.   Results The follow up rate was 97%. Baseline data were evenly...

  2. Optimal Needle Grasp Selection for Automatic Execution of Suturing Tasks in Robotic Minimally Invasive Surgery.

    Science.gov (United States)

    Liu, Taoming; Çavuşoğlu, M Cenk

    2015-05-01

    This paper presents algorithms for optimal selection of needle grasp, for autonomous robotic execution of the minimally invasive surgical suturing task. In order to minimize the tissue trauma during the suturing motion, the best practices of needle path planning that are used by surgeons are applied for autonomous robotic surgical suturing tasks. Once an optimal needle trajectory in a well-defined suturing scenario is chosen, another critical issue for suturing is the choice of needle grasp for the robotic system. Inappropriate needle grasp increases operating time requiring multiple re-grasps to complete the desired task. The proposed methods use manipulability, dexterity and torque metrics for needle grasp selection. A simulation demonstrates the proposed methods and recommends a variety of grasps. Then a realistic demonstration compares the performances of the manipulator using different grasps.

  3. SR and LR Union Suture for the Treatment of Myopic Strabismus Fixus: Is Scleral Fixation Necessary?

    Directory of Open Access Journals (Sweden)

    Carol P. S. Lam

    2015-01-01

    Full Text Available Purpose. To evaluate and compare the effectiveness of scleral fixation SR and LR union suture and nonscleral fixation union suture for the treatment of myopic strabismus fixus. Methods. Retrospective review of 32 eyes of 22 patients with myopic strabismus fixus who had undergone union suture of superior rectus (SR and lateral rectus (LR with or without scleral fixation, and follow-up longer than 6 months at Hong Kong Eye Hospital from 2006 to 2013. Surgical techniques and outcomes in terms of ocular alignment are analyzed. Results. There is significant overall improvement both in postoperative angle of esodeviation (P0.05. Conclusions. Union suture of SR and LR is an effective procedure in correcting myopic strabismus fixus. Fixation of the union suture to the sclera does not improve surgical outcome.

  4. Sutures versus staples for wound closure in orthopaedic surgery: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Shantz Jesse A

    2012-06-01

    Full Text Available Abstract Background A recently published meta-analysis comparing metallic staples to sutures in orthopaedic procedures revealed three fold increase in risk for infection in stapled wounds. The studies included in the meta-analysis are at risk of bias due to experimental design limitations. A large randomized controlled trial is proposed to direct orthopaedic surgeons in their choice of wound closure material. Methods/Design A parallel group randomized controlled trial with institutional review board approval will be conducted. Patients will be randomized intraoperatively to have skin wounds closed with sutures or staples. Dressings will be used to maintain blinding outcome assessors. The primary outcome measure will be a composite all-cause wound complication outcome measure composed of: infection, wound drainage, wound necrosis, blistering, dehiscence, suture abscess and material sensitivity reaction. An independent review board blinded to treatment assignment will adjudicate suspected complications based on clinical data. All deceased patients will also be reviewed. An interim analysis of complications will take place after half of the patients have been recruited. All data will be analyzed by a blinded statistician. Dichotomous primary and secondary outcome measures will be analyzed using the Chi-squared statistic. Continuous outcome measures will be analyzed using Student's t-test. Subgroup analysis will compare infection rates using sutures versus staples in each anatomic area (upper extremity, pelvis/acetabulum, hip/femur, knee, ankle. A further subgroup analysis will be conducted comparing trauma patients to elective surgery patients. Non-infected revision surgery will also be compared to primary surgery. Discussion Wound closure material is an afterthought for many orthopaedic surgeons. The combined results of several comparative trials suggests that the choice of wound closure materials may have an impact on the rate of surgical site

  5. Suture anchor repair of patellar tendon rupture after total knee arthroplasty.

    Science.gov (United States)

    Kamath, Atul F; Shah, Roshan P; Summers, Nathan; Israelite, Craig L

    2013-12-01

    Extensor mechanism disruption after total knee arthroplasty (TKA) is a complex problem that often requires surgical repair for functional deficits. We present a brief technical note on suture anchor fixation of a patellar tendon rupture after TKA. A surgical technique and literature review follows. Although suture anchor fixation is well described for tendinous repairs in other areas of orthopedic surgery, no study has discussed the use of suture anchors in patellar tendon repair after TKA. The technique must be evaluated in more patients with longer follow-up before adoption.

  6. Freeman's transorbital lobotomy as an anomaly: A material culture examination of surgical instruments and operative spaces.

    Science.gov (United States)

    Collins, Brianne M; Stam, Henderikus J

    2015-05-01

    In 1946, Walter Freeman introduced the transorbital ice pick lobotomy. Touted as a procedure that could be learned and subsequently performed by psychiatrists outside of the operating room, the technique was quickly criticized by neurosurgeons. In this article, we take a material culture approach to consider 2 grounds upon which neurosurgeons based their objections-surgical instruments and operative spaces. On both counts, Freeman was in contravention of established normative neurosurgical practices and, ultimately, his technique was exposed as an anomaly by neurosurgeons. Despite its rejection, the transorbital lobotomy became entrenched in contemporary memory and remains the emblematic procedure of the psychosurgery era. (c) 2015 APA, all rights reserved).

  7. Arthroscopic suture bridge technique for intratendinous tear of rotator cuff in chronically painful calcific tendinitis of the shoulder.

    Science.gov (United States)

    Ji, Jong-Hun; Shafi, Mohamed; Moon, Chang-Yun; Park, Sang-Eun; Kim, Yeon-Jun; Kim, Sung-Eun

    2013-11-01

    Arthroscopic removal, now the main treatment option, has almost replaced open surgery for treatment of resistant calcific tendinitis. In some cases of chronic calcific tendinitis of the shoulder, the calcific materials are hard and adherent to the tendon. Removal of these materials can cause significant intratendinous tears between the superficial and deep layers of the degenerated rotator cuff. Thus far, there are no established surgical techniques for removing the calcific materials while ensuring cuff integrity. Good clinical results for rotator cuff repair were achieved by using an arthroscopic suture bridge technique in patients with long-standing calcific tendinitis. Intact rotator cuff integrity and recovery of signal change on follow-up magnetic resonance imaging scans were confirmed. This is a technical note about a surgical technique and its clinical results with a review of relevant published reports. © 2013 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  8. Intracorporeal Suturing and Knot Tying Broadens the Clinical Applicability of Laparoscopy

    Science.gov (United States)

    Rivas, Homero; Cacchione, Robert N.; Ferzli, George S.

    2003-01-01

    Objective: As surgeons become more experienced with basic laparoscopic procedures like cholecystectomy, they are able to expand this approach to less common operations. However, without laparoscopic suturing skills, like those obtained with Nissen fundoplication, many operations cannot be completed laparoscopically. We present a series of 10 patients with less common surgical illnesses who were successfully treated with minimal access techniques and intracorporeal suturing. Methods: Over a 6-month period at 2 medical centers, 10 patients underwent operations with laparoscopic intracorporeal suturing and knot tying. Diagnoses included bowel obstruction due to gallstone ileus (n=1), perforated uterus from an intrauterine device (n=1), urinary bladder diverticulum (n=1), bleeding Meckel's diverticulum (n=3), and perforated duodenal ulcer (n=4). Results: Each patient was treated with standard surgical interventions performed entirely laparoscopically with intracorporeal suturing. No morbidity or mortality occurred in any patient due to the operation. Conclusions: Although each of these operations has been previously reported, as a series, they point out the importance of mastering laparoscopic suturing. Although devices are commercially available to facilitate certain suturing scenarios, we encourage residents and fellows to sew manually. We believe that none of these operations could have been completed as effectively by using a suture device. The ability to suture laparoscopically markedly broadens the number of clinical scenarios in which minimal access techniques can be used. PMID:12856844

  9. Rehabilitation of long-standing facial nerve paralysis with percutaneous suture-based slings.

    Science.gov (United States)

    Alam, Daniel

    2007-01-01

    Long-standing facial paralysis creates significant functional and aesthetic problems for patients affected by this deficit. Traditional approaches to correct this problem have involved aggressive open procedures such as unilateral face-lifts and sling procedures using fascia and implantable materials. Unfortunately, our results with these techniques over the last 5 years have been suboptimal. The traditional face-lift techniques did not address the nasolabial fold to our satisfaction, and suture-based techniques alone, while offering excellent short-term results, failed to provide a long-term solution. This led to the development of a novel percutaneous technique combining the minimally invasive approach of suture-based lifts with the long-term efficacy of Gore-Tex-based slings. We report our results with this technique for static facial suspension in patients with long-standing facial nerve paralysis and our surgical outcomes in 13 patients. The procedure offers re-creation of the nasolabial crease and suspension of the oral commissure to its normal anatomic relationships. The recovery time is minimal, and the operation is performed as a short outpatient procedure. Long-term 2-year follow-up has shown effective preservation of the surgical results.

  10. Efeito da anti-sepsia da ferida cirúrgica alveolar sobre o crescimento bacteriano em fios de sutura de algodão Effect of the antisepsis of the alveolar surgical wound on bacterial growth over cotton suture threads

    Directory of Open Access Journals (Sweden)

    Ulysses Nicida SOARES

    2001-03-01

    Full Text Available Embora os fios de sutura empregados rotineiramente em cirurgias bucais possam favorecer o acúmulo e o crescimento bacteriano, há poucos trabalhos na literatura relatando preocupação com a anti-sepsia da ferida cirúrgica durante o período pós-operatório e antes de sua remoção. O presente trabalho teve por objetivo avaliar o efeito de dois métodos de anti-sepsia intra-oral sobre o crescimento bacteriano em fios de sutura de algodão. Os resultados evidenciaram que todos os fios de sutura apresentaram-se contaminados com estreptococos, antes e após a anti-sepsia da ferida cirúrgica. A análise dos resultados obtidos permitiu concluir que os dois métodos de anti-sepsia avaliados reduziram o número de estreptococos isolados dos fragmentos de fios de sutura, entretanto, a análise estatística demonstrou que os dois métodos avaliados não apresentaram diferenças estatisticamente significantes.The objective of this study was to evaluate bacterial growth on cotton suture. The efficiency of cetylpyridinium chloride (50%, hydrogen peroxide (3% and chlorhexidine (0.12% in antisepsis was investigated. For that, 20 patients who were submitted to extraction of impacted lower third molars were studied. Five days after extraction, samples were obtained from the oral and alveolar sides of the sutures, before and after antisepsis of the wounds, and were submitted to bacteriological analysis. Bacterial growth was observed in all examined samples. The number of streptococci decreased after antisepsis and there were no statistically significant differences between the methods of antisepsis used.

  11. Evaluation of Sternal Closure with Absorbable Polydioxanone Sutures in Children

    Directory of Open Access Journals (Sweden)

    Hamid Bigdelian

    2014-03-01

    Full Text Available Introduction: Sternal dehiscence, sternal wound infection and mediastinitis are troublesome complications following median sternotomy which are major causes of morbidity and mortality of patients. Synthetic polydioxanone absorbable suture seems effective in prevention of these complications in children undergoing open heart surgery.Methods: During 2 years period, 620 patients who underwent median sternotomy were studied. The efficacy of absorbable polydioxanone suture was tested on patients using figure-of-eight suture technique. The patients’ age ranged from newborn to 15 years old. All surgical interventions were performed according to a standard protocol.Results: No sternal sutures were broken during the sternal closure and no case of mediastinitis was seen. Two patients experienced sternal dehiscence (0.32%. Follow-up period of patients were established between 1 to 132 months after open heart surgery.Conclusion: Sternal closure with the polydioxanone suture in combination with figure-of-eight technique is a safe and suitable method in children with good clinical results.

  12. Biomechanical Study of Two Peripheral Suture Methods on Repaired Tendons

    Science.gov (United States)

    Qiu, Zhenling

    2015-01-01

    Flexor digitorum tendon injuries are challenging conditions to manage to ensure optimal patient outcomes. While several surgical approaches with high success rates have been developed, there remains no gold standard for suture technique for the repair of flexor tendon injuries. In this study, we compared two distinct peripheral suture methods on the strength of repaired tendons. Pig flexor digitorum profundus tendons were used in biomechanical studies and the biomechanical influence on tendon repair of continuous running peripheral suture (CRPS) and continuous locking peripheral suture (CLPS), were compared, using stitch length ranging from 1mm to 5mm. In CRPS, the 1mm stitch length group displayed the highest maximum load and breaking power, which was 1.57 fold higher than the 2mm stitch length group. Pairwise comparison revealed that the 1 and 2mm groups were statistically different from the 3, 4, and 5mm stitch length groups while comparison among the latter groups was not statistically significant. For CLPS, the 1mm group exhibited consistently the highest maximum load strength and breaking power, which was twice the strength displayed by the 2mm group. Pairwise comparisons between groups showed statistical significance. For future repairs of flexor tendon injuries, 1mm stitch length is highly recommended for simple peripheral suture.

  13. Recognizing surgeon's actions during suture operations from video sequences

    Science.gov (United States)

    Li, Ye; Ohya, Jun; Chiba, Toshio; Xu, Rong; Yamashita, Hiromasa

    2014-03-01

    Because of the shortage of nurses in the world, the realization of a robotic nurse that can support surgeries autonomously is very important. More specifically, the robotic nurse should be able to autonomously recognize different situations of surgeries so that the robotic nurse can pass necessary surgical tools to the medical doctors in a timely manner. This paper proposes and explores methods that can classify suture and tying actions during suture operations from the video sequence that observes the surgery scene that includes the surgeon's hands. First, the proposed method uses skin pixel detection and foreground extraction to detect the hand area. Then, interest points are randomly chosen from the hand area so that their 3D SIFT descriptors are computed. A word vocabulary is built by applying hierarchical K-means to these descriptors, and the words' frequency histogram, which corresponds to the feature space, is computed. Finally, to classify the actions, either SVM (Support Vector Machine), Nearest Neighbor rule (NN) for the feature space or a method that combines "sliding window" with NN is performed. We collect 53 suture videos and 53 tying videos to build the training set and to test the proposed method experimentally. It turns out that the NN gives higher than 90% accuracies, which are better recognition than SVM. Negative actions, which are different from either suture or tying action, are recognized with quite good accuracies, while "Sliding window" did not show significant improvements for suture and tying and cannot recognize negative actions.

  14. Synthetic surgical meshes used in abdominal wall surgery: Part I-materials and structural conformation.

    Science.gov (United States)

    Todros, S; Pavan, P G; Natali, A N

    2017-04-01

    Surgical implants are commonly used in abdominal wall surgery for hernia repair. Many different prostheses are currently offered to surgeons, comprising permanent synthetic polymer meshes and biologic scaffolds. There is a wide range of synthetic meshes currently available on the market with differing chemical compositions, fiber conformations, and mesh textures. These chemical and structural characteristics determine a specific biochemical and mechanical behavior and play a crucial role in guaranteeing a successful post-operative outcome. Although an increasing number of studies report on the structural and mechanical properties of synthetic surgical meshes, nowadays there are no consistent guidelines for the evaluation of mechanical biocompatibility or common criteria for the selection of prostheses. The aim of this work is to review synthetic meshes by considering the extensive bibliography documentation of their use in abdominal wall surgery, taking into account their material and structural properties, in Part I, and their mechanical behavior, in Part II. The main materials available for the manufacture of polymeric meshes are described, including references to their chemical composition, fiber conformation, and textile structural properties. These characteristics are decisive for the evaluation of mesh-tissue interaction process, including foreign body response, mesh encapsulation, infection, and adhesion formation. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 689-699, 2017. © 2015 Wiley Periodicals, Inc.

  15. Biomechanical study on the suture strength of ligament in cruciate ligament reconstruction

    Institute of Scientific and Technical Information of China (English)

    张春礼; 李起鸿; 杨柳

    2003-01-01

    Objective: To test the suture strength on the tendon or ligament end and evaluate the stitch in the reconstruction of cruciate ligament and its clinical application. Methods: Twenty-four specimens of patellar tendon with free ends were divided into 3 groups: Group I (3 Krackow stitches), Group II (2 Krackow stitches) and Group III (2 Krackow stitches with the first stitch passing through the tendon tissue as a modified Krackow stitch). These 3 groups were further divided into 6 subgroups according to different suture materials, No 1 Ethilon or stainless steel wire (φ= 0.4 mm). Tensile test was undertaken to find out the least stitches with efficient suture pattern. Results: Two Krackow locking stitches had stronger strength than 0.4 mm-diameter stainless steel wire. The fixation strength of 2 stitches with No 1 Ethilon was more than 80 N, superior to the failure strength of the material itself. The same strength was maintained if the first stitch was across the tendon tissue transversely. There was no statistically significant difference in the suture strength between 2 and 3 Krackow locking stitches. Conclusions: The suture strength is greater than the failure strength of the suture material. Less suture exposure can be achieved when the first stitch is across the tendon tissue while maintaining a comparable strength to other sutures. To attain higher suture strength, stronger materials or multiple strands rather than more stitches are preferred. Therefore, a rapid early rehabilitation of range of motion (ROM) is possible and reliable in practice.

  16. First investigation of spider silk as a braided microsurgical suture.

    Science.gov (United States)

    Kuhbier, Joern W; Reimers, Kerstin; Kasper, Cornelia; Allmeling, Christina; Hillmer, Anja; Menger, Björn; Vogt, Peter M; Radtke, Christine

    2011-05-01

    Inhibition of axonal outgrowth accompanied by neuroma formation appears in microsurgical nerve repair as reaction to common microsuture materials like silk, nylon, or polyglycolic acid. In contrast, recent findings revealed advantages of spider silk fibers in guiding Schwann cells in nerve regeneration. Here, we asked if we could braid microsutures from native spider silk fibers. Microsutures braided of native spider dragline silk were manufactured, containing either 2 × 15 or 3 × 10 single fibres strands. Morphologic appearance was studied and tensile strength and stress-strain ratio (SSR) were calculated. The constructed spider silk sutures showed a median thickness of 25 μm, matching the USP definition of 10-0. Maximum load and tensile strength for both spider silk microsutures were significantly more than 2-fold higher than for nylon suture; SSR was 1.5-fold higher. All values except elasticity were higher in 3 × 10 strand sutures compared to 2 × 15 strand sutures, but not significantly. In this pilot study, we demonstrate the successful manufacture of microsutures from spider silk. With regards to the mechanical properties, these sutures were superior to nylon sutures. As spider silk displays high biocompatibility in nerve regeneration, its usage in microsurgical nerve repair should be considered. Copyright © 2011 Wiley Periodicals, Inc.

  17. Development of braided drug-loaded nanofiber sutures

    Energy Technology Data Exchange (ETDEWEB)

    Hu Wen [School of Materials Science and Engineering, Tongji University, 1239 Siping Road, Shanghai 200092 (China); Huang Zhengming [School of Aerospace Engineering and Applied Mechanics, Tongji University, 1239 Siping Road, Shanghai 200092 (China); Liu Xiangyang, E-mail: huangzm@tongji.edu.cn [Department of Physics, National University of Singapore, 2 Science Drive 3, 117542 (Singapore)

    2010-08-06

    The objectives of this work are twofold. Firstly, while most work on electrospinning is limited to the development of only functional materials, a structural application of electrospun nanofibers is explored. Secondly, a drug-loaded tissue suture is fabricated and its various properties are characterized. Braided drug-loaded nanofiber sutures are obtained by combining an electrospinning process with a braiding technique followed by a coating procedure. Two different electrospinning techniques, i.e. blend and coaxial electrospinning, to incorporate a model drug cefotaxime sodium (CFX-Na) into poly(L-lactic acid) (PLLA) nanofibers have been applied and compared with each other. Properties of the braided drug-loaded sutures are characterized through a variety of methods including SEM, TEM and tensile testing. The results show that the nanofibers had a preferable micromorphology. The drug was incorporated into the polymer nanofibers homogeneously, with no cross-linking. The nanofibers maintained their fibrous structures. An in vitro release study indicates that the drug-loaded nanofibers fabricated by blend electrospinning and coaxial electrospinning had a different drug release behavior. An inhibition zone experiment shows that both sutures obtained from the nanofibers of the different electrospinning techniques had favorable antibacterial properties. The drug-loaded sutures had preferable histological compatibility performance compared with commercial silk sutures in an in vivo comparative study.

  18. Trapezium excision and suture suspensionplasty (TESS) for the treatment of thumb carpometacarpal arthritis.

    Science.gov (United States)

    Putnam, Matthew D; Meyer, Nicholas J; Baker, Daniel; Brehmer, Jess; Carlson, Brent D

    2014-06-01

    Basilar thumb arthritis, or first carpometacarpal arthritis, is a common condition affecting older women and some men. It is estimated that as many as one third of postmenopausal woman are affected. Surgical treatment of this condition includes options ranging from arthrodesis to prosthetic arthroplasty. Intermediate options include complete or partial trapezial excision with or without interposition of a cushioning/stabilizing material (auto source, allo source, synthetic source). A multitude of methods appear to offer similar end results, although some methods definitely involve more surgical work and perhaps greater patient risk. Through retrospective evaluation of a cohort of patients who underwent suture suspensionplasty, we determined the postoperative effect on strength, motion, patient satisfaction, complications, and radiographic maintenance of the scaphoid-metacarpal distance. This review shows the method to be clinically effective and, by comparison with a more traditional ligament reconstruction trapezial interposition arthroplasty, the method does not require use of autograft or allograft tendon and has fewer surgical steps. Forty-four patients were included in this retrospective study. The results showed that 91% of patients were satisfied with the procedure. Pinch and grip strength remained the same preoperatively and postoperatively. A Disabilities of the Arm, Shoulder, and Hand patient-reported outcome instrument (DASH) scores averaged 30 at final follow-up. Three patients developed a late complication requiring further surgical intervention. In summary, this technique appears to be technically reproducible, requires no additional tendon material, and achieves objectively and subjectively similar results to other reported procedures used to manage first CMC Arthritis.

  19. An investigation of the fixation materials for cartilage frames in microtia.

    Science.gov (United States)

    Sakamoto, Aritaka; Kiyokawa, Kensuke; Rikimaru, Hideaki; Watanabe, Koichi; Nishi, Yukiko

    2012-05-01

    When performing auriculoplasty for microtia surgery, wires are typically used to fix the costal cartilage frames. However, cases in which such wires become exposed during a long-term follow-up were frequently observed at our facility. Hence, using various materials, we conducted an investigation of the materials most suitable for fixation. The subjects consisted of 122 cases in which auriculoplasty by costal cartilage graft surgery was performed and the postoperative course was traceable, within approximately 24 years from January 1984 to March 2007. Regarding the fixation materials used in the 84 cases in which wire was used, 5 cases used monofilament non-absorbable sutures (Nylon(®)), 5 cases used monofilament absorbable sutures (PDS(®)), and 28 cases used braided absorbable sutures(VICRYL(®)).Their postoperative course was investigated, and the presence of auricular deformities caused by a loosening of the fixation materials and the exposure of the fixation materials was examined. An exposure of the wire was observed in 19 cases (22.6%) of the 84 cases that used wires. An exposure of nylon was observed in 2 (40%) of 5 the cases that used nylon, and of those, a mild deformation was observed in the lower helix in one case that was suspected to have been caused by a loosening of the surgical suture. Regarding the 33 cases in which absorbable sutures were used (5 cases used monofilament absorbable sutures and 28 cases used braided absorbable sutures), neither any auricular deformities nor exposure of the fixation materials was observed in any of the cases. Whether using monofilament or braided sutures, absorbable sutures are therefore believed to be the most suitable material for the fixation of cartilage. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Basal joint osteoarthritis of the thumb: comparison of suture button versus abductor pollicis longus suspensionplasty.

    Science.gov (United States)

    Avant, Kristopher R; Nydick, Jason A; White, Brian D; Vaccaro, Lisa; Hess, Alfred V; Stone, Jeffrey D

    2015-03-01

    Our purpose was to compare the outcomes of patients with severe basilar thumb osteoarthritis treated with trapeziectomy and suspensionplasty using abductor pollicis longus (APL) tendon versus a suture button device. A retrospective study was performed for patients undergoing trapeziectomy and suspensionplasty with APL tendon or suture button fixation. Outcome measures included disabilities of the arm, shoulder, and hand (DASH); visual analog score (VAS); grip strength; key pinch; tip pinch; and thumb opposition. Radiographic measurements, surgical times, and complications were recorded. Thirty-three patients in the APL tendon group and 27 patients in the suture button group had a minimum 6-month follow-up. VAS, DASH, and functional measurements improved after surgery for both groups. Mean operative time was 68 min for the APL tendon group and 48 min for the suture button group. Complications were similar between groups. The use of suture button fixation when compared to APL tendon suspensionplasty offers similar clinical outcomes. Therapeutic III.

  1. Transcutaneous Serdev Suture For Buttock’s Lift

    OpenAIRE

    Nikolay Serdev

    2012-01-01

    This article presents the author's technique and experience in the treatment of the flaccid "unhappy buttock" form with his surgical procedure of buttock lift by suture, without incision scars. The author first presented this new operation technique on a national level at the 2nd Annual Meeting of the National Bulgarian Society for Aesthetic Surgery and Aesthetic Medicine in Sofia on March 18, 1994 [1] and internationally at many scientific meetings over the world [2, 3, 4…]. The result is a ...

  2. Sutured Floer homology and hypergraphs

    CERN Document Server

    Juhász, András; Rasmussen, Jacob

    2011-01-01

    By applying Seifert's algorithm to a special alternating diagram of a link L, one obtains a Seifert surface F of L. We show that the support of the sutured Floer homology of the sutured manifold complementary to F is affine isomorphic to the set of lattice points given as hypertrees in a certain hypergraph that is naturally associated to the diagram. This implies that the Floer groups in question are supported in a set of Spin^c structures that are the integer lattice points of a convex polytope. This property has an immediate extension to Seifert surfaces arising from homogeneous link diagrams (including all alternating and positive diagrams). In another direction, together with work in progress of the second author and others, our correspondence suggests a method for computing the "top" coefficients of the HOMFLY polynomial of a special alternating link from the sutured Floer homology of a Seifert surface complement for a certain dual link.

  3. Randomized comparison of polyglycolic acid and polyglyconate sutures for abdominal fascial closure after laparotomy in patients with suspected impaired wound healing

    DEFF Research Database (Denmark)

    Osther, P J; Gjøde, P; Mortensen, Sophie Berit Bondegaard

    1995-01-01

    A randomized study of abdominal fascial closure using interrupted polyglyconate and polyglycolic acid sutures after laparotomy was carried out in 204 consecutive patients with suspected impaired wound healing. There were no statistically significant differences between the two sutures with regard...... to the development of fascial disruption and incisional hernia. Wound infection demanding surgical intervention was found in 7 per cent of patients with polyglyconate sutures and in 16 per cent of those with polyglycolic acid sutures (P = 0.04). Monofilament polyglyconate suture does not reduce the incidence...

  4. Comparison of different fixation methods of the suture-button implant for tibiofibular syndesmosis injuries.

    Science.gov (United States)

    Teramoto, Atsushi; Suzuki, Daisuke; Kamiya, Tomoaki; Chikenji, Takako; Watanabe, Kota; Yamashita, Toshihiko

    2011-10-01

    Suture-button fixation for tibiofibular syndesmosis injuries is a relatively new surgical technique thought to provide semirigid dynamic stabilization. However, adequate information is still not available and there are controversies as to whether it provides enough fixation for syndesmosis injuries. Optimally directed suture-button fixation brings physiologic dynamic stabilization of the ankle syndesmosis. Controlled laboratory study. Stabilization of the ankle syndesmosis fixed by a suture-button construct was examined using 6 normal fresh-frozen cadaver legs. After initial tests of intact and injured models, suture-button fixation and screw surgical techniques were performed sequentially for each specimen, with single suture-button fixation, double suture-button fixation, anatomic suture-button fixation, and metal screw. Anterior and medial traction forces, as well as external rotation force, were applied to the tibia; the diastasis of the syndesmosis and the rotational angle of the fibula related to the tibia were measured using a magnetic tracking system. Each traction and rotation force significantly increased the diastasis and fibular rotational angles in the created injury models. With single fixation, the diastases increased significantly compared with the intact model with an anterior traction force (P button can provide adequate stabilization of the ankle and could benefit athletes with syndesmosis injuries.

  5. Prospective randomized controlled trial investigating the type of sutures used during hepatectomy

    Institute of Scientific and Technical Information of China (English)

    Norifumi Harimoto; Ken Shirabe; Tomoyuki Abe; Takafumi Yukaya; Eiji Tsujita; Tomonobu Gion; Kiyoshi Kajiyama; Takashi Nagaie

    2011-01-01

    AIM: To determine whether absorbable sutures or non-absorbable sutures are better in preventing surgical site infection (SSI), in this paper we discuss the results of a randomized clinical trial which examined the type of sutures used during hepatectomy. METHODS: All hepatic resections performed from January 2007 to November 2008 at the Department of Surgery at Iizuka Hospital in Japan were included in this study. There were 125 patients randomly assigned to an absorbable sutures (Vicryl) group or non-absorbable sutures (Silk) group. RESULTS: SSI was observed in 13.6% (17/125) patients participating in this study, 11.3% in the Vicryl group and 15.8% in the Silk group. Incisional SSI including superficial and deep SSI, was observed in 8% of the Vicryl group and 9.5% of the Silk group. Organ/ space SSI was observed in 3.2% of the Vicryl group and 6.0% of the Silk group. There were no significant differences, but among the patients with SSI, the period for recovery was significantly shorter for the Vicryl group compared to the Silk group. CONCLUSION: The incidence of SSI in patients receiving absorbable sutures and silk sutures is not significantly different in this randomized controlled study; however, the period for recovery in patients with SSI was significantly shorter for absorbable sutures.

  6. Surgical innovations in canine gonadectomy

    NARCIS (Netherlands)

    Van Goethem, Bart

    2016-01-01

    In this thesis some recent technological developments in human surgery are evaluated for their potential use in veterinary medicine by introducing them as surgical innovations for canine gonadectomy. Barbed sutures achieve wound apposition without surgical knot tying and thus avoid knot-associated n

  7. Surgical innovations in canine gonadectomy

    NARCIS (Netherlands)

    Van Goethem, Bart

    2016-01-01

    In this thesis some recent technological developments in human surgery are evaluated for their potential use in veterinary medicine by introducing them as surgical innovations for canine gonadectomy. Barbed sutures achieve wound apposition without surgical knot tying and thus avoid knot-associated n

  8. Torsion of monofilament and polyfilament sutures under tension decreases suture strength and increases risk of suture fracture.

    LENUS (Irish Health Repository)

    Hennessey, D B

    2012-08-01

    A continuous running suture is the preferential method for abdominal closure. In this technique the suture is secured with an initial knot and successive tissue bites are taken. At each tissue bite, the needle is rotated through the tissue; in doing so, the suture can twist around the knot which acts as an anchor.

  9. One strategy for arthroscopic suture fixation of tibial intercondylar eminence fractures using the Meniscal Viper Repair System

    Directory of Open Access Journals (Sweden)

    Ochiai Satoshi

    2011-08-01

    Full Text Available Abstract Background Principles for the treatment of tibial intercondylar eminence fracture are early reduction and stable fixation. Numerous ways to treatment of this fracture have been invented. We designed a simple, low-invasive, and arthroscopic surgical strategy for tibial intercondylar eminence fracture utilizing the Meniscal Viper Repair System used for arthroscopic meniscal suture. Methods We studied 5 patients, who underwent arthroscopic suture fixation that we modified. The present technique utilized the Meniscal Viper Repair System for arthroscopic suture of the meniscus. With one handling, a high-strength ultra-high molecular weight polyethylene(UHMWPE suture can be passed through the anterior cruciate ligament (ACL and the loops for suture retrieval placed at both sides of ACL. Surgical results were evaluated by the presence or absence of bone union on plain radiographs, postoperative range of motion of the knee joint, the side-to-side differences measured by Telos SE, and Lysholm scores. Results The reduced position achieved after surgery was maintained and good function was obtained in all cases. The mean distance of tibia anterior displacement and assessment by Lysholm score showed good surgical results. Conclusion This method simplified the conventional arthroscopic suture fixation and increased its precision, and was applicable to Type II fractures that could be reduced, as well as surgically indicated Types III and IV. The present series suggested that our surgical approach was a useful surgical intervention for tibial intercondylar eminence fracture.

  10. UTILIZAÇÃO DO ADESIVO METIL-2-CIANOACRILATO E FIO DE NÁILON NA REPARAÇÃO DE FERIDAS CUTÂNEAS DE CÃES E GATOS UTILIZATION OF THE METHYL-2-CYANOACRYLATE ADHESIVE AND THE NYLON SUTURE IN SURGICAL SKIN WOUNDS OF DOGS AND CATS

    Directory of Open Access Journals (Sweden)

    Vanja Andrade Gueiros

    2001-04-01

    Full Text Available Com o objetivo de avaliar e comparar clínica e histologicamente o uso do adesivo metil-2-cianoacrilato e do fio de náilon na reparação de feridas cirúrgicas de pele, foram utilizados cinco cães e cinco gatos adultos, clinicamente sadios. Seguindo o protocolo anestésico e cirúrgico habitual para cada espécie, foram feitas cinco incisões na pele da região costal do lado esquerdo e cinco do lado direito, com aproximadamente dois centímetros de comprimento. As feridas cirúrgicas do lado direito foram suturadas com fio de náilon cirúrgico 3-0 e as do lado esquerdo foram aproximadas e fixadas com o metil-2-cianoacrilato em ambas as espécies. Os animais foram submetidos a avaliações clínicas a cada três dias. Foram retirados fragmentos de pele para realização de biopsias aos três, seis, nove, doze e quinze dias após a cirurgia. Os resultados obtidos, tanto em cães quanto em gatos, não revelaram diferença clínica ou histológica entre os tratamentos utilizados.The purpose of this study is to evaluate and compare clinically and histologically the use of methyl-2-cyanoacrylate adhesive versus the nylon's suture in skin wounds closure. There were five adult mongrel dogs and cats, clinically healthy used. Following anaesthetical routine and surgical protocol, five incisions were made in the left costal region, and other five in right costal region, about 2cm in length, in both especies. The right side costal wounds were sutured with surgical nylon 3-0, and in the left side costal wounds methyl-2-cyanoacrylate was applied, in both species. The animals were submitted to clinical evaluation every three days, and a biopsy was realized at three, six, nine, twelve and fifteen days after the surgery. In both species, the results did not show any clinical or histologic difference when comparing the used treatments.

  11. Effect of recombinant human platelet-derived growth factor-BB-coated sutures on Achilles tendon healing in a rat model: A histological and biomechanical study

    Directory of Open Access Journals (Sweden)

    Stephen H Cummings

    2012-12-01

    Full Text Available Purpose: Repairing tendon injuries with recombinant human platelet-derived growth factor-BB has potential for improving surgical outcomes. Augmentation of sutures, a critical component of surgical tendon repair, by coating with growth factors may provide a clinically useful therapeutic device for improving tendon repair. Therefore, the purpose of this study was to (a coat Vicryl sutures with a defined dose of recombinant human platelet-derived growth factor-BB without additional coating excipients (e.g. gelatin, (b quantify the recombinant human platelet-derived growth factor-BB released from the suture, and (c use the recombinant human platelet-derived growth factor-BB-coated sutures to enhance tendon repair in a rat Achilles tendon transection model. Methods: Vicryl sutures were coated with 0, 0.3, 1.0, and 10.0 mg/mL concentrations of recombinant human platelet-derived growth factor-BB using a dip-coating process. In vitro release was quantified by an enzyme-linked immunosorbent assay. Acutely transected rat Achilles tendons were repaired using one of the four suture groups (n = 12 per group. Four weeks following repair, the tensile biomechanical and histological (i.e. collagen organization and angiogenesis properties were determined. Results: A dose-dependent bolus release of recombinant human platelet-derived growth factor-BB occurred within the first hour in vitro, followed by a gradual release over 48 h. There was a significant increase in ultimate tensile strength (p < 0.01 in the two highest recombinant human platelet-derived growth factor-BB dose groups (1.9 ± 0.5 and 2.1 ± 0.5 MPa relative to controls (1.0 ± 0.2 MPa. The modulus significantly increased (p = 0.031 with the highest recombinant human platelet-derived growth factor-BB dose group (7.2 ± 3.8 MPa relative to all other groups (control: 3.5 ± 0.9 MPa. No significant differences were identified for the maximum load or stiffness. The histological collagen and angiogenesis

  12. Unusual sutural bones at pterion

    Directory of Open Access Journals (Sweden)

    Nayak SB

    2008-08-01

    Full Text Available The existence of Wormian (sutural bones in the skull is well known. We found three unusual Wormian bones at the right pterion in an adult Indian skull. The variation noted was unilateral. This type of variation has not been reported yet.

  13. Peer-assisted teaching of basic surgical skills

    Directory of Open Access Journals (Sweden)

    Ryan Preece

    2015-06-01

    Full Text Available Background: Basic surgical skills training is rarely emphasised in undergraduate medical curricula. However, the provision of skills tutorials requires significant commitment from time-constrained surgical faculty. Purpose: We aimed to determine how a peer-assisted suturing workshop could enhance surgical skills competency among medical students and enthuse them towards a career in surgery. Methods: Senior student tutors delivered two suturing workshops to second- and third- year medical students. Suturing performance was assessed before and after teaching in a 10-min suturing exercise (variables measured included number of sutures completed, suture tension, and inter-suture distance. Following the workshop, students completed a questionnaire assessing the effect of the workshop on their suturing technique and their intention to pursue a surgical career. Results: Thirty-five students attended. Eighty-one percent believed their medical school course provided insufficient basic surgical skills training. The mean number of sutures completed post-teaching increased significantly (p<0.001, and the standard deviation of mean inter-suture distance halved from ±4.7 mm pre-teaching, to ±2.6 mm post-teaching. All students found the teaching environment to be relaxed, and all felt the workshop helped to improve their suturing technique and confidence; 87% found the peer-taught workshop had increased their desire to undertake a career in surgery. Discussion: Peer-assisted learning suturing workshops can enhance medical students’ competence with surgical skills and inspire them towards a career in surgery. With very little staff faculty contribution, it is a cheap and sustainable way to ensure ongoing undergraduate surgical skills exposure.

  14. Peer-assisted teaching of basic surgical skills

    Science.gov (United States)

    Preece, Ryan; Dickinson, Emily Clare; Sherif, Mohamed; Ibrahim, Yousef; Ninan, Ann Susan; Aildasani, Laxmi; Ahmed, Sartaj; Smith, Philip

    2015-01-01

    Background Basic surgical skills training is rarely emphasised in undergraduate medical curricula. However, the provision of skills tutorials requires significant commitment from time-constrained surgical faculty. Purpose We aimed to determine how a peer-assisted suturing workshop could enhance surgical skills competency among medical students and enthuse them towards a career in surgery. Methods Senior student tutors delivered two suturing workshops to second- and third- year medical students. Suturing performance was assessed before and after teaching in a 10-min suturing exercise (variables measured included number of sutures completed, suture tension, and inter-suture distance). Following the workshop, students completed a questionnaire assessing the effect of the workshop on their suturing technique and their intention to pursue a surgical career. Results Thirty-five students attended. Eighty-one percent believed their medical school course provided insufficient basic surgical skills training. The mean number of sutures completed post-teaching increased significantly (p<0.001), and the standard deviation of mean inter-suture distance halved from ±4.7 mm pre-teaching, to ±2.6 mm post-teaching. All students found the teaching environment to be relaxed, and all felt the workshop helped to improve their suturing technique and confidence; 87% found the peer-taught workshop had increased their desire to undertake a career in surgery. Discussion Peer-assisted learning suturing workshops can enhance medical students’ competence with surgical skills and inspire them towards a career in surgery. With very little staff faculty contribution, it is a cheap and sustainable way to ensure ongoing undergraduate surgical skills exposure. PMID:26044400

  15. Braiding Parameters of Medical Silk Braided Suture

    Institute of Scientific and Technical Information of China (English)

    张佩华; 吴建华

    2001-01-01

    The relationships between braiding parameters and properties of medical silk braided suture are investigated. Experimental results indicate that the main factors affecting the suture properties include the proportion of core silk and shell silk, braiding density and braiding tension. The results show that the braiding technology significantly influences the suture properties and the optimal braiding parameters were obtained by using the regression method.

  16. Evaluating the Effectiveness of the Lateral Intercrural Suture to Decrease the Interdomal Distance to Improve the Definition of the Nasal Tip in Primary Rhinoplasty

    Directory of Open Access Journals (Sweden)

    Soares, Caio Márcio Correia

    2014-04-01

    Full Text Available Introduction Several surgical techniques emphasizing sutures on the lower lateral cartilage have been studied by surgeons as instruments to improve nasal tip remodeling. It is already known that the domal divergence angle and its definition angle can be modified by lateral intercrural suture (LIS. Techniques for measuring these structures are not yet standardized. Objectives Assess the efficacy of LIS using polydioxanone 4–0 absorbable thread by interdomal distance and systematize the LIS technique to improve nasal tip definition. Materials and Methods This prospective study measured and analyzed interdomal distances measured preoperatively and perioperatively compared with 3- and 6-month postoperative measurements. Results LIS was efficient on reducing interdomal distances. Conclusion LIS is statistically safe and efficient and has low morbidity when utilized in patients with mild to moderate deformities, because it reduces the domal divergence angle, effectively sustaining the nasal tip.

  17. Surgically Correctable Morbidity from Male Circumcision: Indications ...

    African Journals Online (AJOL)

    INTRODUCTION. Circumcision, the surgical removal of the prepuce, is probably the .... circumcision bleeding had haemostatic sutures applied while three patients with .... bridge after clamping with artery forcep for about 3-5 minutes following ...

  18. Triclosan-coated sutures and sternal wound infections: a prospective randomized clinical trial.

    Science.gov (United States)

    Steingrimsson, S; Thimour-Bergström, L; Roman-Emanuel, C; Scherstén, H; Friberg, Ö; Gudbjartsson, T; Jeppsson, A

    2015-12-01

    Surgical site infection is a common complication following cardiac surgery. Triclosan-coated sutures have been shown to reduce the rate of infections in various surgical wounds, including wounds after vein harvesting in coronary artery bypass grafting patients. Our purpose was to compare the rate of infections in sternotomy wounds closed with triclosan-coated or conventional sutures. A total of 357 patients that underwent coronary artery bypass grafting were included in a prospective randomized double-blind single-center study. The patients were randomized to closure of the sternal wound with either triclosan-coated sutures (Vicryl Plus and Monocryl Plus, Ethicon, Inc., Somerville, NJ, USA) (n = 179) or identical sutures without triclosan (n = 178). Patients were followed up after 30 days (clinical visit) and 60 days (telephone interview). The primary endpoint was the prevalence of sternal wound infection according to the Centers for Disease Control and Prevention (CDC) criteria. The demographics in both groups were comparable, including age, gender, body mass index, and rate of diabetes and smoking. Sternal wound infection was diagnosed in 43 patients; 23 (12.8%) sutured with triclosan-coated sutures compared to 20 (11.2%) sutured without triclosan (p = 0.640). Most infections were superficial (n = 36, 10.1%), while 7 (2.0%) were deep sternal wound infections. There were 16 positive cultures in the triclosan group and 17 in the non-coated suture group (p = 0.842). The most commonly identified main pathogens were Staphylococcus aureus (45.4%) and coagulase-negative staphylococci (36.4%). Skin closure with triclosan-coated sutures did not reduce the rate of sternal wound infection after coronary artery bypass grafting. (clinicaltrials.gov: NCT01212315).

  19. Complexity of serrated sutures of a human skull

    Directory of Open Access Journals (Sweden)

    Kochenkova О.V.

    2011-09-01

    Full Text Available Objective: to reveal the variability mechanism of complexity of serrated sutures of a human skull in the correlation with cranial form. Materials and methods. Researches of 253 arches of male and female skulls of patients at the age of 1 day-105 years without signs of cranial trauma or skeletal systemic diseases with absence of morphological signs of increase of intracranial pressure. Minimal (Min and maximal (Max values, average arithmetic (M, a mistake of average arithmetic (m have been studied. For definition of reliability of average size difference parametrical and non-parametric statistical criteria were used: parametrical criterion (t-criterion of Student applied for parameters submitting to the law of normal distribution (Lakin G. R, 1990. Distinctions of average arithmetic size were considered statistically authentic from 95% (p<0,05 a level of correct judgement (Plokhinskiy N.A., 1970. Results. On the surface of the arch lambdoid and coronal sutures in male skulls and lambdoid and sagittal sutures in female were found out to be of the greatest degree of complexity. Conclusion. The increase of complexity of sutures has been observed in children and adolescents; the directed asymmetry of sutures form is absent

  20. Developing Customized Dental Miniscrew Surgical Template from Thermoplastic Polymer Material Using Image Superimposition, CAD System, and 3D Printing

    Directory of Open Access Journals (Sweden)

    Yu-Tzu Wang

    2017-01-01

    Full Text Available This study integrates cone-beam computed tomography (CBCT/laser scan image superposition, computer-aided design (CAD, and 3D printing (3DP to develop a technology for producing customized dental (orthodontic miniscrew surgical templates using polymer material. Maxillary bone solid models with the bone and teeth reconstructed using CBCT images and teeth and mucosa outer profile acquired using laser scanning were superimposed to allow miniscrew visual insertion planning and permit surgical template fabrication. The customized surgical template CAD model was fabricated offset based on the teeth/mucosa/bracket contour profiles in the superimposition model and exported to duplicate the plastic template using the 3DP technique and polymer material. An anterior retraction and intrusion clinical test for the maxillary canines/incisors showed that two miniscrews were placed safely and did not produce inflammation or other discomfort symptoms one week after surgery. The fitness between the mucosa and template indicated that the average gap sizes were found smaller than 0.5 mm and confirmed that the surgical template presented good holding power and well-fitting adaption. This study addressed integrating CBCT and laser scan image superposition; CAD and 3DP techniques can be applied to fabricate an accurate customized surgical template for dental orthodontic miniscrews.

  1. Developing Customized Dental Miniscrew Surgical Template from Thermoplastic Polymer Material Using Image Superimposition, CAD System, and 3D Printing

    Science.gov (United States)

    Yu, Jian-Hong; Lo, Lun-Jou; Hsu, Pin-Hsin

    2017-01-01

    This study integrates cone-beam computed tomography (CBCT)/laser scan image superposition, computer-aided design (CAD), and 3D printing (3DP) to develop a technology for producing customized dental (orthodontic) miniscrew surgical templates using polymer material. Maxillary bone solid models with the bone and teeth reconstructed using CBCT images and teeth and mucosa outer profile acquired using laser scanning were superimposed to allow miniscrew visual insertion planning and permit surgical template fabrication. The customized surgical template CAD model was fabricated offset based on the teeth/mucosa/bracket contour profiles in the superimposition model and exported to duplicate the plastic template using the 3DP technique and polymer material. An anterior retraction and intrusion clinical test for the maxillary canines/incisors showed that two miniscrews were placed safely and did not produce inflammation or other discomfort symptoms one week after surgery. The fitness between the mucosa and template indicated that the average gap sizes were found smaller than 0.5 mm and confirmed that the surgical template presented good holding power and well-fitting adaption. This study addressed integrating CBCT and laser scan image superposition; CAD and 3DP techniques can be applied to fabricate an accurate customized surgical template for dental orthodontic miniscrews. PMID:28280726

  2. Achilles Tendon Rupture: Avoiding Tendon Lengthening during Surgical Repair and Rehabilitation

    Science.gov (United States)

    Maquirriain, Javier

    2011-01-01

    Achilles tendon rupture is a serious injury for which the best treatment is still controversial. Its primary goal should be to restore normal length and tension, thus obtaining an optimal function. Tendon elongation correlates significantly with clinical outcome; lengthening is an important cause of morbidity and may produce permanent functional impairment. In this article, we review all factors that may influence the repair, including the type of surgical technique, suture material, and rehabilitation program, among many others. PMID:21966048

  3. Self-directed practice schedule enhances learning of suturing skills.

    Science.gov (United States)

    Safir, Oleg; Williams, Camille K; Dubrowski, Adam; Backstein, David; Carnahan, Heather

    2013-12-01

    Most preoperative surgical training programs experience challenges with the availability of expert surgeons to teach trainees. Some research suggests that trainees may benefit from being allowed to actively shape their learning environments, which could alleviate some of the time and resource pressures in surgical training. The purpose of this study was to investigate the effects of self-directed or prescribed practice schedules (random or blocked) on learning suturing skills. Participants watched an instructional video for simple interrupted, vertical mattress and horizontal mattress suturing then completed a pretest to assess baseline skills. Participants were assigned to 1 of 4 practice groups: self-directed practice schedule, prescribed blocked practice schedule, prescribed random practice schedule or matched to the self-directed group (control). Practice of the skill was followed by a delayed (1 h) posttest. Improvement from pretest to posttest was determined based on differences in performance time and expert-based assessments. Analyses revealed a significant effect of group for difference in performance time of the simple interrupted suture. Random practice did not show the expected advantage for skill learning, but there was an advantage of self-directed practice. Self-directed practice schedules may be desirable for optimal learning of simple technical skills, even when expert instruction is available. Instructors must also take into account the interaction between task difficulty and conditions of practice to develop ideal training environments.

  4. Absorbable Polydioxanone (PDS) suture provides fewer wound complications than polyester (ethibond) suture in acute Tendo-Achilles rupture repair

    LENUS (Irish Health Repository)

    Baig, M N

    2017-05-01

    We prospectively studied acute Achilles tendon rupture in patients over a two 2-year period and reviewed the causes, outcome and complications. There were 53 patients included with acute Achilles rupture with minimum follow up period of 6 months. We compared the outcomes including infection rate and Boyden score between the two groups repaired by Polydioxanone and Polyester respectively. All infected cases had a suture repair using the polyester suture. The difference in the infection rate was highly significant between the 2 groups (p=0.001). All 34 patients (100%) in the PDS group had good \\/ excellent results based on the Boyden clinical assessment. Conversely, only 16 patients 9(68.4%) had good or excellent results IN Polyester repair group. Patients treated with a non- absorbable suture (ethibond) material for repair had a higher incidence infection and worse Boyden scores than the absorbable PDS group.

  5. Uso do pericárdio autólogo para reforço da aortorrafia no tratamento cirúrgico da valva aórtica The use of autologous pericardium to reinforce the aorta suture in the surgical treatment of the aortic valve

    Directory of Open Access Journals (Sweden)

    Marco Antonio Vieira Guedes

    2004-12-01

    Full Text Available O reparo da aortotomia no tratamento cirúrgico da valva aórtica pode ser realizado por meio de diferentes técnicas. Em alguns casos, porém, a aorta ascendente encontra-se aterosclerótica, fina e friável, aumentando o risco de rotura no pós-operatório imediato e formação tardia de aneurismas. Este trabalho descreve uma técnica de reforço da aortorrafia com a utilização de pericárdio autólogo e seus resultados, através da análise retrospectiva de 23 casos realizados no Instituto do Coração de São Paulo, entre 1999 e 2003.The repair of the aortotomy in the surgical treatment of aortic valve can be achieved using different techniques. Nevertheless, in some cases, the ascending aorta is atherosclerotic, thin and friable, making the risk of aorta rupture and late aneurysm development higher. This article describes the technique and the results obtained from the reinforcement of aortic suture with autologous pericardium by retrospective analysis of 23 cases from the Heart Institute of São Paulo, between 1999 and 2003.

  6. [Surgical wound healing in oral surgery].

    Science.gov (United States)

    Bocca, M; Coscia, D; Bottalico, L; Libro, D

    1999-12-01

    Aim of this study is to improve the in vivo knowledge about the real effects and the physiologic repair by a detached stitches silk suture in the 8th zone. The study has been carried out on 44 patients submitted to surgical extraction of the impacted 8th (19 upper and 25 lower) teeth. Clinical and histological controls have demonstrated the usefulness of this suture procedure, since it gives a good histological reaction and in easy and safe. Histological and clinical results have confirmed the usefulness of silk suture, presenting however the inconvenience of stitches removal and bacterial plaque on the surgical wound.

  7. An Alternative Bundle-to-Bundle Suturing Technique for Repairing Fresh Achilles Tendon Rupture.

    Science.gov (United States)

    Zhao, Jingjing; Yu, Bin; Xie, Ming; Huang, Ruokun; Xiao, Kai

    2016-01-01

    The main concern about conventional Achilles tendon repair surgical techniques is how to maintain the initial strength of the ruptured Achilles tendon through complicated suturing methods. The primary surgical problem lies in the properties of the soft tissue; the deterioration of the Achilles tendon, especially in its elasticity; and the surface lubricity of the local tissues. In the present study, we describe an innovative bundle-to-bundle suturing method that addresses these potential problems. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Midpalatal suture maturation: Classification method for individual assessment before rapid maxillary expansion

    Science.gov (United States)

    Angelieri, Fernanda; Cevidanes, Lucia H. S.; Franchi, Lorenzo; Gonçalves, João R.; Benavides, Erika; McNamara, James A.

    2014-01-01

    Introduction In this study, we present a novel classification method for individual assessment of midpalatal suture morphology. Methods Cone-beam computed tomography images from 140 subjects (ages, 5.6-58.4 years) were examined to define the radiographic stages of midpalatal suture maturation. Five stages of maturation of the midpalatal suture were identified and defined: stage A, straight high-density sutural line, with no or little interdigitation; stage B, scalloped appearance of the high-density sutural line; stage C, 2 parallel, scalloped, high-density lines that were close to each other, separated in some areas by small low-density spaces; stage D, fusion completed in the palatine bone, with no evidence of a suture; and stage E, fusion anteriorly in the maxilla. Intraexaminer and interexaminer agreements were evaluated by weighted kappa tests. Results Stages A and B typically were observed up to 13 years of age, whereas stage C was noted primarily from 11 to 17 years but occasionally in younger and older age groups. Fusion of the palatine (stage D) and maxillary (stage E) regions of the midpalatal suture was completed after 11 years only in girls. From 14 to 17 years, 3 of 13 (23%) boys showed fusion only in the palatine bone (stage D). Conclusions This new classification method has the potential to avoid the side effects of rapid maxillary expansion failure or unnecessary surgically assisted rapid maxillary expansion for late adolescents and young adults. PMID:24182592

  9. Caudal Septal Stabilization Suturing Technique to Treat Crooked Noses.

    Science.gov (United States)

    Baykal, Bahadir; Erdim, Ibrahim; Guvey, Ali; Oghan, Fatih; Kayhan, Fatma Tulin

    2016-10-01

    To rotate the nasal axis and septum to the midline using an L-strut graft and a novel caudal septal stabilization suturing technique to treat crooked noses. Thirty-six patients were included in the study. First, an L-strut graft was prepared by excising the deviated cartilage site in all patients. Second, multiple stabilization suturing, which we describe as a caudal septal stabilization suturing technique with a "fishing net"-like appearance, was applied between the anterior nasal spine and caudal septum in all patients. This new surgical technique, used to rotate the caudal septum, was applied to 22 I-type and 14 C-type crooked noses. Correction rates for the crooked noses were compared between the 2 inclination types with angular estimations. Deviation angles were measured using the AutoCAD 2012 software package and frontal (anterior) views, with the Frankfurt horizontal line parallel to the ground. Nasal axis angles showing angle improvement graded 4 categories as excellent, good, acceptable, and unsuccessful for evaluations at 6 months after surgery in the study. The success rate in the C-type nasal inclination was 86.7% (±21.9) and 88% (±16.7) in the I-type. The overall success rate of L-strut grafting and caudal septal stabilization suturing in crooked nose surgeries was 87.5% (±18.6). "Unsuccessful" results were not reported in any of the patients. L-strut grafting and caudal septal stabilization suturing techniques are efficacious in crooked noses according to objective measurement analysis results. However, a longer follow-up duration in a larger patient population is needed.

  10. An Alternative Alar Cinch Suture

    Science.gov (United States)

    Rauso, Raffaele; Freda, Nicola; Curinga, Giuseppe; Del Pero, Claudio; Tartaro, Gianpaolo

    2010-01-01

    Nasal widening is commonly associated to maxillary osteotomies, but it is only partially dependent on the amount of skeletal movement. Techniques for controlling lateralization of the ala, including the alar base cinch technique, originally described by Millard, have been well reported by Collins and Epker and later modified by others. In this article, authors report the effect of a new alar cinch suture technique on a sample of 32 patients. PMID:21187940

  11. Prediction of rapid maxillary expansion by assessing the maturation of the midpalatal suture on cone beam CT

    Directory of Open Access Journals (Sweden)

    Fernanda Angelieri

    Full Text Available ABSTRACT Rapid maxillary expansion (RME primarily involves the mechanical opening of the midpalatal suture of the maxillary and palatine bones. The fusion of the midpalatal suture determines the failure of RME, a common event in late adolescents and young adults. Recently, the assessment of the maturation of midpalatal suture as viewed using cone beam computed tomography (CBCT has been introduced. Five maturational stages of the midpalatal suture have been presented: Stage A = straight high-density sutural line, with no or little interdigitation; Stage B = scalloped appearance of the high-density sutural line; Stage C = two parallel, scalloped, high-density lines that lie close to each other, separated in some areas by small low-density spaces; Stage D = fusion of the palatine bone where no evidence of a suture is present; and Stage E = complete fusion that extends also anteriorly in the maxilla. At Stage C, less skeletal response would be expected than at Stages A and B, as there are many bony bridges along the suture. For patients at Stages D and E, surgically assisted RME would be necessary, as the fusion of the midpalatal suture already has occurred either partially or totally. This diagnostic method can be used to estimate the prognosis of the RME, mainly for late adolescents and young adults for whom this procedure is unpredictable clinically.

  12. Prediction of rapid maxillary expansion by assessing the maturation of the midpalatal suture on cone beam CT

    Science.gov (United States)

    Angelieri, Fernanda; Franchi, Lorenzo; Cevidanes, Lucia H. S.; Bueno-Silva, Bruno; McNamara, James A.

    2016-01-01

    ABSTRACT Rapid maxillary expansion (RME) primarily involves the mechanical opening of the midpalatal suture of the maxillary and palatine bones. The fusion of the midpalatal suture determines the failure of RME, a common event in late adolescents and young adults. Recently, the assessment of the maturation of midpalatal suture as viewed using cone beam computed tomography (CBCT) has been introduced. Five maturational stages of the midpalatal suture have been presented: Stage A = straight high-density sutural line, with no or little interdigitation; Stage B = scalloped appearance of the high-density sutural line; Stage C = two parallel, scalloped, high-density lines that lie close to each other, separated in some areas by small low-density spaces; Stage D = fusion of the palatine bone where no evidence of a suture is present; and Stage E = complete fusion that extends also anteriorly in the maxilla. At Stage C, less skeletal response would be expected than at Stages A and B, as there are many bony bridges along the suture. For patients at Stages D and E, surgically assisted RME would be necessary, as the fusion of the midpalatal suture already has occurred either partially or totally. This diagnostic method can be used to estimate the prognosis of the RME, mainly for late adolescents and young adults for whom this procedure is unpredictable clinically. PMID:28125147

  13. Suture anchor versus suture through tunnel fixation for quadriceps tendon rupture: a biomechanical study.

    Science.gov (United States)

    Lighthart, William A; Cohen, David A; Levine, Richard G; Parks, Brent G; Boucher, Henry R

    2008-05-01

    This biomechanical study compared suture anchors versus transosseous sutures for repair of quadriceps tendon ruptures using a force of 150 N at a frequency of 0.5 Hz. No significant difference in displacement was found between the 2 techniques with initial loading or with load or no load after 1000 cycles. Displacement after 1000 cycles for suture anchors and bone tunnels was 4.65 and 4.50 mm, respectively. These findings suggest a possible role for suture anchors in repairing quadriceps tendon ruptures. Suture anchors are relatively expensive but require less dissection over the patella and do not involve suture placement about the patella tendon.

  14. Análise da densidade óptica da sutura palatina mediana seis meses após a expansão rápida da maxila assistida cirurgicamente Evaluation of the midpalatal suture optical density six months after surgically assisted rapid maxillary expansion

    Directory of Open Access Journals (Sweden)

    Mônica Cunha Macedo

    2009-10-01

    Full Text Available OBJETIVO: avaliar a neoformação óssea da sutura palatina mediana por meio da análise de densidade óptica após a expansão rápida da maxila assistida cirurgicamente (ERMAC. MÉTODOS: a amostra estudada consistiu de 16 pacientes, sendo 6 do gênero masculino e 10 do gênero feminino. Todos os pacientes apresentavam atresia maxilar com mordida cruzada posterior e foram submetidos à ERMAC. Foram realizadas radiografias oclusais parciais da região dos incisivos superiores em quatro fases: antes da ERMAC (fase I, após o fim da ativação do parafuso expansor (fase II, três meses após a ativação do parafuso expansor (fase III, e seis meses após a ERMAC (fase IV. Uma escala de alumínio com oito degraus, variando de 1 a 8mm, foi adaptada no extremo das radiografias. A análise da densidade óptica foi feita após a digitalização das radiografias, utilizando-se o software Image Tool® (UTHSCSA, San Antonio, Texas, EUA. Em cada uma dessas fases, duas áreas foram selecionadas e analisadas. A região "A" (anterior mediu 8 x 1mm² e localizou-se a 1,2cm da tangente situada nos incisivos centrais superiores na região da sutura palatina mediana. A região "B" (posterior mediu 5 x 9mm² e localizou-se a 4,3cm da tangente situada nos incisivos centrais superiores na região da sutura palatina mediana. RESULTADOS: na região "A", comparando-se a fase I com a fase II, e a fase I com a fase III, foram encontradas diferenças estatisticamente significativas - p 0,05 entre as fases I e IV.AIM: This study evaluated the new bone formation in the midpalatal suture after surgically assisted rapid maxillary expansion by optical density analysis. METHODS: The sample was comprised by 16 patients (six males and ten females. All patients presented maxillary atresia with posterior crossbite and were submitted to SARME. Maxillary occlusal radiographs were taken at four stages (before SARME, immediately after SARME, three months after SARME and six months

  15. Healing of periodontal flaps when closed with silk sutures and N-butyl cyanoacrylate: A clinical and histological study

    Directory of Open Access Journals (Sweden)

    Kulkarni Sudhindra

    2007-01-01

    Full Text Available Background: The closure of the periodontal flaps post-surgery is a necessity for attainment of a primary union between the flap margins and the establishment of a healthy dentogingival junction. N-butyl cyanoacrylate is a tissue adhesive, which can be used for the closure of the incised wounds to overcome the problems associated with conventional suture materials like silk. Objective: The present study was carried out to assess the healing of the periodontal flaps when closed with the conventional silk sutures and N-butyl cyanoacrylate. Materials and Methods: The study was carried out on 24 patients who needed flap surgical procedure for pocket therapy. Results: It was found that healing with the cyanoacrylate is associated with less amount of inflammation during the first week when compared with silk. However, over a period of 21 days to 6 weeks, the sites treated with both the materials showed similar healing patterns. Conclusion: It can be concluded that cyanoacrylate aids in early initial healing.

  16. Age changes in the human frontozygomatic suture from 20 to 95 years.

    Science.gov (United States)

    Kokich, V G

    1976-04-01

    The frontozygomatic suture of human cadaver material was examined by a combination of histologic, radiographic, and gross tecniques to determine the aging changes in the suture and the approximate age at which sutural fusion occurs. The sample consisted of sixty-One specimens of human beings ranging in age from 20 to 95 years. Observations were made on specimens at age intervals of 5 years. Since the frontozygomatic suture is bilateral, one suture from each specimens was used for radiographic and gross examination for synostosis, and the opposite side was subjected to histologic analysis. The findings of this study have lead to the following conclusions: 1. The human frontozygomatic suture undergoes synostosis during the eigth decade of life, but does not completely fuse by the age of 95 years. 2. Synostosis is a progressive process which commences as small areas of bony union that occur initially within the internal portion of the suture and then progresses to the orbital perisosteal surface. Bony union is not found at or near the facial periosteal surface. 3. The bony surfaces of the frontozygomatic suture become increasingly irregular with advancing age as a result of the formation of projections or interifitations=

  17. Medial grasping sutures significantly improve load to failure of the rotator cuff suture bridge repair.

    Science.gov (United States)

    Awwad, George E; Eng, Kevin; Bain, Gregory I; McGuire, Duncan; Jones, Claire F

    2014-05-01

    The suture bridge (SB) transosseous-equivalent rotator cuff repair reduces re-tear rates compared with single-row or other double-row constructs. However, failure rates continue to be high, especially in large and massive tears. The aim of this study was to assess the biomechanical performance of a new SB repair with use of a medial grasping suture compared with the traditional SB repair. Seven matched pairs of sheep infraspinatus tendons were randomly assigned to either SB or suture bridge with grasping suture (SBGS) repair. Each construct was subjected to cyclic loading and then loaded until failure under displacement control in a materials testing machine. Footprint displacement, ultimate load to failure, and mode of failure were assessed. The rotator cuff footprint displacement was less during tensile loading with the addition of the medial grasping suture. The ultimate load to failure was significantly greater for the SBGS repair group than for the SB repair group (334.0 N vs 79.8 N). The mode of failure was the tendon pulling off the footprint in all cases (type 1 tear). There were no failures in which the tendon tore at the medial row of anchors, leaving part of the tendon still on the footprint (type 2 tear). The addition of a medial grasping suture significantly improved the ultimate load to failure and reduced the footprint displacement of the SB rotator cuff repair in a biomechanical model. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  18. CORNEAL ASTIGMATISM AFTER ECCE: A COMPARATIVE STUDY BETWEEN SILK VERSUS NYLON SUTURE

    Directory of Open Access Journals (Sweden)

    Sunita

    2013-11-01

    Full Text Available ABSTRAC T: INTRODUCTION: Cataract as a potent cause of loss of vision in old age persons is probably known since the dawn of human civilization. Post operative astigmatism after cataract extraction remains a big problem for cataract surgeons since Jacques Daviel e ra. Astigmatism is that type of refractive anomaly in which no point focus is formed owing to the unequal refraction of the incident light by the diopteric system of the eye in different meridians. The goal of modern cataract surgery is to produce a pseudo phakic with the quality of vision of a normal phakic eye. Various studies to find out any effect of IOL on post operative astigmatism were carried out but results are controversial. MATERIAL AND METHODS: 60 patients suffering from cataract and fit for extr action were enlisted during the month of August 2008 to February 2009. The general, physical and local examination including preoperative Keratometry, vision and tension were recorded. RESULTS: In the present study, male patients were 38 (63% and female p atients were 22 (37%. Out of the total 60 cases studied, corneo - scleral section of 28 cases (47% were sutured with 10 - 0 nylon suture (Group A while sections of 32 cases were sutured with 8 - 0 black virgin silk suture (Group B.Out of 28 cases of Group A, interrupted sutures were applied in 14 cases (50% (Group A 1 . Cross interrupted sutures were applied in 9 cases (32% Group A 2 , while bootlace continuous sutures were applied in 5 cases (18% (Group A 3 . Out of 32 cases of Group B, interrupted sutures we re applied in 26 cases (80% (Group B 1 , cross interrupted were applied in 3 cases (10% (Group B 2 , while bootlace continuous suture were applied in 3 cases (Group B 3 . In the present series, 19 cases (31% showed with the rule astigmatism, 21 cases (36% showed astigmatism against the rule and 20 cases (33% showed no astigmatism preoperatively, 16 cases were in the range of 0.50D to 1.0D and 12 cases were in the range of 1

  19. Is the pterygopalatomaxillary suture (sutura sphenomaxillaris) a growing suture in the fetus?

    Science.gov (United States)

    Vacher, C; Onolfo, J P; Barbet, J P

    2010-08-01

    The pterygopalatomaxillary suture is considered as having an important role in the posteroanterior growing of the maxilla. To determine whether this suture is a growing suture in the fetus, we performed a histological study of this suture in a fetus aged of 16 weeks of amenorrhea. Serial sections (5 microm) of the pterygopalatomaxillary suture area have been performed. Fibrous sutures are separating four pieces of ossification (maxilla, palatine bone, lateral and medial plates of the pterygoid process). A fibroblastic growing site has been observed on the dorsal aspect of the pterygopalatomaxillary suture, in contact to the anterior border of the lateral plate of the pterygoid process. The posteroanterior growing of maxilla is dependent on a growing suture located on the anterior border of the pterygoid process. The pterygoid process (via its lateral plate) makes the junction between the maxilla and both the cranial base and the condylar mandibular site of growth.

  20. Bio-inspired ``jigsaw''-like interlocking sutures: Modeling, optimization, 3D printing and testing

    Science.gov (United States)

    Malik, I. A.; Mirkhalaf, M.; Barthelat, F.

    2017-05-01

    Structural biological materials such as bone, teeth or mollusk shells draw their remarkable performance from a sophisticated interplay of architectures and weak interfaces. Pushed to the extreme, this concept leads to sutured materials, which contain thin lines with complex geometries. Sutured materials are prominent in nature, and have recently served as bioinspiration for toughened ceramics and glasses. Sutures can generate large deformations, toughness and damping in otherwise all brittle systems and materials. In this study we examine the design and optimization of sutures with a jigsaw puzzle-like geometry, focusing on the non-linear traction behavior generated by the frictional pullout of the jigsaw tabs. We present analytical models which accurately predict the entire pullout response. Pullout strength and energy absorption increase with higher interlocking angles and for higher coefficients of friction, but the associated high stresses in the solid may fracture the tabs. Systematic optimization reveals a counter-intuitive result: the best pullout performance is achieved with interfaces with low coefficient of friction and high interlocking angle. We finally use 3D printing and mechanical testing to verify the accuracy of the models and of the optimization. The models and guidelines we present here can be extended to other types of geometries and sutured materials subjected to other loading/boundary conditions. The nonlinear responses of sutures are particularly attractive to augment the properties and functionalities of inherently brittle materials such as ceramics and glasses.

  1. Comparação dos gastos com material para reparação de perfurações de córnea com cola de cianoacrilato e sutura de córnea Comparative cost evaluation in corneal perforation repair with cyanoacrylate adhesive versus corneal suture

    Directory of Open Access Journals (Sweden)

    Emerson Lioji Ueda

    2004-02-01

    Full Text Available OBJETIVO: Avaliação comparativa de custos de reparação de pequenas perfurações oculares utilizando a técnica da cola de cianoacrilato Super Bonder® (2-metil-cianoacrilato comparada à técnica de sutura de córnea. MÉTODOS: A fim de avaliar comparativamente os custos do uso da técnica de cola de cianoacrilato com a técnica de sutura de córnea, realizou-se análise dos materiais usados em ambas técnicas. RESULTADOS: A análise de custos comparativos entre o uso da técnica de cola de cianoacrilato em pequenas perfurações, versus a técnica de sutura de córnea demonstrou menor gasto com uso do adesivo. CONCLUSÃO: A utilização da técnica de cola de cianoacrilato, para reparação de perfuração de córnea, apresentou custos menores quando comparada com a técnica de sutura de córnea.PURPOSE: The aim of this study was performing a comparative evaluation of cost in small ocular perforation repair using cyanoacrylate adhesive technique Super BonderTM (methyl-2-cyanoacrylate as compared with corneal suture technique. METHODS: In order to compare evaluations of cost a cost analysis in "reais" (R$ was conducted for both techniques according to the materials used in cyanoacrylate glue technique and the corneal suture. RESULTS: The analysis of comparative cost of the cyanoacrylate adhesive technique in small perforations versus corneal suture showed a lower cost of the former. CONCLUSION: Lower cost was found for the cyanoacrylate glue technique for corneal perforation repair when compared to the corneal suture technique.

  2. Factors influencing surgical outcome after anterior stabilization of the cervical spine with heterogeneous material

    Directory of Open Access Journals (Sweden)

    Athanasios K. Petridis

    2012-05-01

    Full Text Available Intervertebral fusion through an anterior approach with polymethylacrylate is a wellestablished neurosurgical technique in the treatment of cervical spine degeneration. However, questions still remain concerning the post-surgical outcome. Factors influencing surgical outcome that could help to predict which patients need further post-surgical treatment and what to expect after surgery are the subject of numerous studies. In the present study, we retrospectively collected data from patients who had undergone intervertebral fusion and defined which pre-operative factors could influence the surgical outcome. Between 1993 and 1997, 379 patients were surgically treated with the ventral fusion technique in our hospital. In 2006, we sent a questionnaire to the patients and 164 responses were received. We identified pre-operative presence of severe pain, hypesthesia, palsy and gait disturbance as negative predictive factors, whereas age, body mass index, pre-operative physical strain and the cervical segment involved did not seem to influence prognosis. In conclusion, identifying preoperative factors which influence prognosis after intervetebral fusion will help predict postoperative outcome.

  3. Use of Absorbable Sutures in Canine Carotid Arteries

    Science.gov (United States)

    Rey, Alejandro R.; Carrillo-Farga, Joaquin; Velasco, Carlos O.; Valencia, Martin O.V.

    1990-01-01

    To study the functional and microstructural characteristics of polydioxanone sutures in vascular surgery, we created 48 vascular anastomoses in the right and left common carotid arteries of 24 mongrel dogs. In each animal, polydioxanone sutures were used in 1 carotid artery, and polypropylene sutures were used in the contralateral carotid artery. Twelve groups of 2 animals each were then formed. The 1st group was observed for 1 month, the 2nd for 2 months, the 3rd for 3 months, and so on until the 12th group, which was observed for 12 months. At the end of each observation period, reoperation was undertaken to evaluate the vascular anastomoses by means of angiography and microscopy. The polypropylene anastomoses showed a marked deformity, with tissue retraction and a foreign body reaction. In contrast, the polydioxanone anastomoses exhibited satisfactory healing, without deformity, and were well tolerated histologically. We believe that polydioxanone may be a useful, alternative vascular suture material. (Texas Heart Institute Journal 1990;17:99-102) Images PMID:15227391

  4. Towards robotic heart surgery: introduction of autonomous procedures into an experimental surgical telemanipulator system.

    Science.gov (United States)

    Bauernschmitt, R; Schirmbeck, E U; Knoll, A; Mayer, H; Nagy, I; Wessel, N; Wildhirt, S M; Lange, R

    2005-09-01

    The introduction of telemanipulator systems into cardiac surgery enabled the heart surgeon to perform minimally invasive procedures with high precision and stereoscopic view. For further improvement and especially for inclusion of autonomous action sequences, implementation of force-feedback is necessary. The aim of our study was to provide a robotic scenario giving the surgeon an impression very similar to open procedures (high immersion) and to enable autonomous surgical knot tying with delicate suture material. In this experimental set-up the feasibility of autonomous surgical knot tying is demonstrated for the first time using stereoscopic view and force feedback. Copyright 2005 John Wiley & Sons, Ltd.

  5. Introduction of a New Suture Method in Repair of Peripheral Nerves Injured with a Sharp Mechanism

    Directory of Open Access Journals (Sweden)

    Alireza Saied

    2015-09-01

    Full Text Available Background: The standard method for repair of an injured peripheal nerve is epineural repair with separate sutures. Herein we describe a method in which the nerve is sutured with continous sutures. In fact this method has not been utilized for nerve repair previously and our purpose was to compare it to the standard method. If it proved to be successful it would replace the standard method in certain circumstances. Methods: The proposal of the clinical trial was given a reference number form the ethics comitee. 25 dogs in which the scaitic nerve was cut by a sharp blade under genaeral anesthesia were divided randomly into three groups: control (5 dogs, repair of sciatic nerve with simple sutures (10 and repair with continous sutures (10. In the control group the nerve was not repaired at all. After 6 weeks the dogs were killed and the nerve was studied by light and electronic microscopes. The amount of consumed suture material, time of repair, myelin thickness and axon diiameter were examined. Ultrastructural studies were performed to assess degeneration and regeneration findings. Results: Time of repair and the amount of consumed suture material were significantly lower in the continous group (P

  6. Nonabsorbable versus absorbable sutures in large, hang-back medial rectus muscle recessions.

    Science.gov (United States)

    Awadein, Ahmed; Marsh, Justin D; Guyton, David L

    2016-06-01

    To investigate the value of nonabsorbable sutures in reducing the incidence of consecutive exotropia after large, "hang-back" medial rectus recessions. The medical records of patients who underwent medial rectus recession of ≥6.5 mm in individuals ≤2 years of age, or ≥7.0 mm in those >2 years were retrospectively reviewed. Patients were divided into two groups based on suture material used: absorbable, polyglactin 910 sutures (44 patients); nonabsorbable, polyester sutures (50 patients). Preoperative measurements, ductions, strabismus surgery, and postoperative results were analyzed. Inadequate anchoring of the medial rectus muscle was suspected when consecutive exotropia developed 4-7 weeks after surgery after initial satisfactory alignment and was confirmed if during reoperation the medial rectus muscle appeared recessed >2 mm beyond the originally intended recession. Consecutive exotropia due to inadequate anchoring of the medial rectus muscle occurred in 11 of 66 muscles (17%) in the absorbable suture group. The muscle was found 6-10 mm posterior to the intended recession. Limited duction in the field of action of the involved medial rectus muscle occurred in 9 of the 11 muscles (82%). None of the eyes with nonabsorbable sutures showed inadequate anchoring. The incidence of consecutive exotropia was higher in the absorbable suture group (30%) than in the nonabsorbable suture group (6%) (P < 0.005). Using nonabsorbable suture for large, hang-back medial rectus recessions greatly reduces the incidence of consecutive exotropia that can occur when absorbable suture dissolves. Copyright © 2016 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  7. Bacterial inhibition potential of quaternised chitosan-coated VICRYL absorbable suture: An in vitro and in vivo study

    Directory of Open Access Journals (Sweden)

    Ying Yang

    2017-01-01

    Conclusion: In general, the present study demonstrated that the quaternised chitosan coating is a flexible and cost-effective alternative strategy to prevent the suture related surgical site infections in orthopaedic practices.

  8. Posterior C1-C2 Fixation Using Absorbable Suture for Type II Odontoid Fracture in 2-Year-Old Child: Description of a New Technique and Literature Review.

    Science.gov (United States)

    Labbe, Jean L; Peres, Olivier; Leclair, Olivier; Goulon, Renaud; Scemama, Patrice; Jourdel, François; Bertrou, Véronique; Murgier, Jerome

    2016-12-01

    Odontoid synchondrosis fractures are rare in children, even though they are the more common cervical fracture in children less than 7 years old. Nonoperative treatment with external orthosis immobilization is the treatment of choice for stable undisplaced or minimally displaced injuries. In unstable fractures, when reduction cannot be achieved or maintained, surgical fixation is recommended. We report a 2-year-old boy with an unstable fracture of the odontoid treated surgically using an absorbable monofilament suture for C1-C2 interlaminar fixation without bone grafting. This suture was strong enough to provide the stability necessary to allow healing of the synchondrosis and the delayed resorption of the suture was followed by complete restoration of the mobility between C1 and C2. This case illustrates that surgical stabilization using an absorbable suture in young children with an unstable odontoid fracture is a safe and effective alternative to other surgical techniques.

  9. USE OF PLASTIC MATERIAL AND TRIPLE SCAN IN THE PREPARATION OF SURGICAL GUIDES FOR THE DENTAL IMPLANT TREATMENT-CASE REPORT

    OpenAIRE

    Rosen Borisov

    2016-01-01

    The use of surgical guides in implant treatment increases the accuracy of the dental implant positioning compared with manual methods. Regardless of how they are made, deviations of implants from their intended position are established in all kinds of surgical guides. This article considers the use of plastic material and new scanning technique for the production of CAD/CAM surgical guides that aim to overcome the deficiencies of the currently applied technologies in the production of surgica...

  10. LigaSure versus Conventional Suture Ligature for Vaginal Hysterectomy: a Randomized Controlled Trial

    OpenAIRE

    Mohamed Abd Elzaher, a, b, Ashraf Moawad, a, c and Hanaa Abu-Ria

    2011-01-01

    Introduction: Vaginal hysterectomy is considered to be the method of choice for removal of the uterus. Of particular concern for the vaginal surgeon is the ability to access, visualize, and legate structures while maintaining adequate hemostasis. Surgical hemostasis can be secured by a variety of methods, including mechanical means (sutures) or vessel coagulation (diathermy). Electro-surgical vessel sealing (LigaSure) is a new hemostatic system based on the combination of pressure and bipolar...

  11. Elastic suture (shoelace technique) for fasciotomy closure after treatment of compartmental syndrome associated to tibial fracture.

    Science.gov (United States)

    Branco, Paulo Sergio Martins Castelo; Cardoso Junior, Mauricio; Rotbande, Isaac; Ciraudo, José Antonio Fraga; Silva, Celso Ricardo Correa de Melo; Leal, Paulo Cesar Dos Santos

    2017-01-01

    This article reports the use of elastic suture as an adjuvant in surgical wound closure caused by decompressive fasciotomy after compartment syndrome associated with a compound fracture of the tibia. Widely used in other medico-surgical specialties, this technique is unusual in orthopedics surgery, but the simplicity of the procedure and the successful outcome observed in this case allows for its consideration as indicated for situations similar to that presented in this study.

  12. A new, removable, sliding noose for adjustable-suture strabismus surgery.

    Science.gov (United States)

    Deschler, Emily K; Irsch, Kristina; Guyton, Kristina L; Guyton, David L

    2013-10-01

    We describe a new removable sliding polyglactin 910 suture noose for postoperative suture adjustment following extraocular muscle surgery. No excess suture material remains after adjustment has been completed, helping to reduce discomfort, inflammation, and scarring. We have used this noose with the cul-de-sac conjunctival incision in approximately 360 patients over a period of 18 months. This report details how to fashion, use, and remove the noose. Copyright © 2013 American Association for Pediatric Ophthalmology and Strabismus. Published by Mosby, Inc. All rights reserved.

  13. Virtual reality robotic surgery simulation curriculum to teach robotic suturing: a randomized controlled trial.

    Science.gov (United States)

    Kiely, Daniel J; Gotlieb, Walter H; Lau, Susie; Zeng, Xing; Samouelian, Vanessa; Ramanakumar, Agnihotram V; Zakrzewski, Helena; Brin, Sonya; Fraser, Shannon A; Korsieporn, Pira; Drudi, Laura; Press, Joshua Z

    2015-09-01

    The objective of this randomized, controlled trial was to assess whether voluntary participation in a proctored, proficiency-based, virtual reality robotic suturing curriculum using the da Vinci(®) Skills Simulator™ improves robotic suturing performance. Residents and attending surgeons were randomized to participation or non-participation during a 5 week training curriculum. Robotic suturing skills were evaluated before and after training using an inanimate vaginal cuff model, which participants sutured for 10 min using the da Vinci(®) Surgical System. Performances were videotaped, anonymized, and subsequently graded independently by three robotic surgeons. 27 participants were randomized. 23 of the 27 completed both the pre- and post-test, 13 in the training group and 10 in the control group. Mean training time in the intervention group was 238 ± 136 min (SD) over the 5 weeks. The primary outcome (improvement in GOALS+ score) and the secondary outcomes (improvement in GEARS, total knots, satisfactory knots, and the virtual reality suture sponge 1 task) were significantly greater in the training group than the control group in unadjusted analysis. After adjusting for lower baseline scores in the training group, improvement in the suture sponge 1 task remained significantly greater in the training group and a trend was demonstrated to greater improvement in the training group for the GOALS+ score, GEARS score, total knots, and satisfactory knots.

  14. The Double-Row Suture Technique: A Better Option for the Treatment of Haglund Syndrome.

    Science.gov (United States)

    Jiang, Yiqiu; Li, Yang; Tao, Tianqi; Li, Wang; Zhang, Kaibin; Gui, Jianchao; Ma, Yong

    2016-01-01

    Purpose. The purpose of this study is to investigate whether double-row suture technique is a better option for the treatment of Haglund syndrome than single-row suture technique regarding the surgical outcomes. Methods. Thirty-two patients with Haglund syndrome were recruited in this study. Patients were divided into Group 1 (treated with single-row suture technique) and Group 2 (treated with double-row suture technique). There were 16 patients in each group. The AOFAS-ankle-hindfoot scale, VISA-A scores, and Arner-Lindholm standard were used to assess the clinical outcomes. The pre- and postoperative X-rays were used to assess the radiological outcome. Results. Both AOFAS-ankle-hindfoot scale score and VISA-A score had varying degrees of improvement in both groups. In latest follow-up assessment, the Arner-Lindholm standard investigation showed there were 7 excellent, 7 good, and 2 bad outcomes in Group 1 and 12 excellent and 4 good outcomes in Group 2. In Group 2 patients, there were no more posterosuperior bony prominence of the calcaneum in post-op X-rays and there were no recurrent cases. The ankle-related scale score was statistically significantly higher in Group 2 than in Group 1 (P = 0.029). Conclusion. The double-row suture technique seems to be a better option to treat Haglund syndrome than single-row suture technique.

  15. The Double-Row Suture Technique: A Better Option for the Treatment of Haglund Syndrome

    Directory of Open Access Journals (Sweden)

    Yiqiu Jiang

    2016-01-01

    Full Text Available Purpose. The purpose of this study is to investigate whether double-row suture technique is a better option for the treatment of Haglund syndrome than single-row suture technique regarding the surgical outcomes. Methods. Thirty-two patients with Haglund syndrome were recruited in this study. Patients were divided into Group 1 (treated with single-row suture technique and Group 2 (treated with double-row suture technique. There were 16 patients in each group. The AOFAS-ankle-hindfoot scale, VISA-A scores, and Arner-Lindholm standard were used to assess the clinical outcomes. The pre- and postoperative X-rays were used to assess the radiological outcome. Results. Both AOFAS-ankle-hindfoot scale score and VISA-A score had varying degrees of improvement in both groups. In latest follow-up assessment, the Arner-Lindholm standard investigation showed there were 7 excellent, 7 good, and 2 bad outcomes in Group 1 and 12 excellent and 4 good outcomes in Group 2. In Group 2 patients, there were no more posterosuperior bony prominence of the calcaneum in post-op X-rays and there were no recurrent cases. The ankle-related scale score was statistically significantly higher in Group 2 than in Group 1 (P=0.029. Conclusion. The double-row suture technique seems to be a better option to treat Haglund syndrome than single-row suture technique.

  16. Low pacemaker incidence with continuous-sutured valves: a retrospective analysis.

    Science.gov (United States)

    Niclauss, Lars; Delay, Dominique; Pfister, Raymond; Colombier, Sebastien; Kirsch, Matthias; Prêtre, René

    2017-06-01

    Background Permanent pacemaker implantation after surgical aortic valve replacement depends on patient selection and risk factors for conduction disorders. We aimed to identify risk criteria and obtain a selected group comparable to patients assigned to transcatheter aortic valve implantation. Methods Isolated sutured aortic valve replacements in 994 patients treated from 2007 to 2015 were reviewed. Demographics, hospital stay, preexisting conduction disorders, surgical technique, and etiology in patients with and without permanent pacemaker implantation were compared. Reported outcomes after transcatheter aortic valve implantation were compared with those of a subgroup including only degenerative valve disease and first redo. Results The incidence of permanent pacemaker implantation was 2.9%. Longer hospital stay ( p = 0.01), preexisting rhythm disorders ( p pacemaker implantation. Although prostheses were sutured with continuous monofilament in the majority of cases (86%), interrupted pledgetted sutures were used more often in the pacemaker group ( p = 0.002). In the subgroup analysis, the incidence of permanent pacemaker implantation was 2%; preexisting rhythm disorders and the suture technique were still major risk factors. Conclusion Permanent pacemaker implantation depends on etiology, preexisting rhythm disorders, and suture technique, and the 2% incidence compares favorably with the reported 5- to 10-fold higher incidence after transcatheter aortic valve implantation. Cost analysis should take this into account. Often dismissed as minor complication, permanent pacemaker implantation increases the risks of endocarditis, impaired myocardial recovery, and higher mortality if associated with prosthesis regurgitation.

  17. Lower Reoperation Rate for Recurrence after Mesh versus Sutured Elective Repair in Small Umbilical and Epigastric Hernias. A Nationwide Register Study

    DEFF Research Database (Denmark)

    Christoffersen, Mette Willaume; Helgstrand, F; Rosenberg, J;

    2013-01-01

    Repair for a small (≤2 cm) umbilical and epigastric hernia is a minor surgical procedure. The most common surgical repair techniques are a sutured repair or a repair with mesh reinforcement. However, the optimal repair technique with regard to risk of reoperation for recurrence is not well...... documented. The aim of the present study was in a nationwide setup to investigate the reoperation rate for recurrence after small open umbilical and epigastric hernia repairs using either sutured or mesh repair....

  18. Minimally invasive surgical technique for tethered surgical drains

    Directory of Open Access Journals (Sweden)

    Shane R Hess

    2017-01-01

    Full Text Available A feared complication of temporary surgical drain placement is from the technical error of accidentally suturing the surgical drain into the wound. Postoperative discovery of a tethered drain can frequently necessitate return to the operating room if it cannot be successfully removed with nonoperative techniques. Formal wound exploration increases anesthesia and infection risk as well as cost and is best avoided if possible. We present a minimally invasive surgical technique that can avoid the morbidity associated with a full surgical wound exploration to remove a tethered drain when other nonoperative techniques fail.

  19. In Vitro Oral Biofilm Formation on Triclosan-Coated Sutures in the Absence and Presence of Additional Antiplaque Treatment

    NARCIS (Netherlands)

    Venema, Sebastiaan; Abbas, Frank; van de Belt-Gritter, Betsy; van der Mei, Henny C.; Busscher, Henk J.; van Hoogmoed, Chris G.

    Purpose: This study evaluated the in vitro plaque inhibitory effect of triclosan-coated polyglactin 910 sutures in the absence and presence of an additional antiplaque agent commonly used after oral surgery. Materials and Methods: Triclosan-coated sutures were incubated for 4 hours in freshly

  20. In Vitro Oral Biofilm Formation on Triclosan-Coated Sutures in the Absence and Presence of Additional Antiplaque Treatment

    NARCIS (Netherlands)

    Venema, Sebastiaan; Abbas, Frank; van de Belt-Gritter, Betsy; van der Mei, Henny C.; Busscher, Henk J.; van Hoogmoed, Chris G.

    2011-01-01

    Purpose: This study evaluated the in vitro plaque inhibitory effect of triclosan-coated polyglactin 910 sutures in the absence and presence of an additional antiplaque agent commonly used after oral surgery. Materials and Methods: Triclosan-coated sutures were incubated for 4 hours in freshly collec

  1. Surgical pearl: the temporary assistant.

    Science.gov (United States)

    Jacobs, Aleda A; Orengo, Ida F

    2008-04-15

    A simple maneuver is presented which simultaneously facilitates both adequate surgical site exposure and sufficient traction. A single suture with high tensile strength can be utilized to this end. This technique is especially helpful when the cutaneous surgeon is operating alone.

  2. Comperative analysis of unilateral cleft lip closure using absorbable and nonabsorbable sutures: a randomised clinical study

    Directory of Open Access Journals (Sweden)

    Abhay Nilkanth Datarkar

    2014-09-01

    Full Text Available Aim: Patients with cleft lip usually undergo multiple procedures that require hospitalization resulting in emotional stress to their family members. Young patients often require sedation or general anesthesia (GA for suture removal on a sensitive area to prevent disruption of the repair. In this study, we compared absorbable and nonabsorbable sutures for primary cleft lip repair. Methods: Patients with cleft lip who presented to Smile Train Unit, Child Hospital and Research Institute, Nagpur, India, were randomly assigned to two groups and underwent surgical repair using either Vicryl Rapid suture (Group 1 or Prolene suture (Group 2. Patients were followed up at 1 month, 6 months, and 1 year. Photographs of the patients were obtained at these visits and rated using a validated 100-mm cosmesis visual analogue scale (VAS by three people (social worker, surgeon, and patient's mother. A VAS score of 15 mm or greater was considered as clinically important difference. Results: A total of 60 patients were enrolled in this study, and they were equally divided into two groups. There was no difference in age, race, sex, wound length, number of sutures, and layered repair rates between the groups. The average age of the patient was 3 months. There was no significant difference in the rates of infection which was 6% in this study, wound dehiscence, and hypertrophic scar formation. No significant difference was found in cosmetic outcome in both the mean VAS score of 90.3 in Group 1 and 91.7 in Group 2. Conclusion: Absorbable sutures are a viable alternative to nonabsorbable sutures in the repair of primary cleft lip repair. We prefer absorbable sutures because they do not require removal under GA or sedation.

  3. Longitudinal parallel compression suture to control postopartum hemorrhage due to placenta previa and accrete.

    Science.gov (United States)

    Li, Guang-Tai; Li, Xiao-Fan; Wu, Baoping; Li, Guangrui

    2016-04-01

    To assess the efficacy and safety of longitudinal parallel compression suture to control heavy postpartum hemorrhage (PPH) in patients with placenta previa/accreta. Fifteen women received a longitudinal parallel compression suture to stop life-threatening PPH due to placenta previa with or without accreta during cesarean section. The suture apposed the anterior and posterior walls of the lower uterine segment together using an absorbable thread A 70-mm round needle with a Number-1 absorbable thread was used. The point of needle entry was 1 cm above the upper margin of the cervix and 1 cm from the right lateral border of the lower segment of the anterior wall. The suture was threaded through the uterine cavity to the serosa of the posterior wall. Then, it was directed upward and threaded from the posterior to the anterior wall at ∼1-2 cm above the upper boundary of the lower uterine segment and 3-cm medial to the right margin of the uterus. Both ends of the suture were tied on the anterior aspect of uterus. The left side was sutured in the same way. The success rate of the procedure was 86.7% (13/15). Two of 15 cases were concurrently administered gauze packing and achieved satisfactory hemostasis. All patients resumed a normal menstrual flow, and no postoperative anatomical or physiological abnormalities related to the suture were observed. Three women achieved further pregnancies after the procedure. Longitudinal parallel compression suture is a safe, easy, effective, practical, and conservative surgical technique to stop intractable PPH from the lower uterine segment, particularly in women who have a cesarean scar and placenta previa/accreta. Copyright © 2016. Published by Elsevier B.V.

  4. Comparison between tenocutaneous suture and Kessler suture techniques in treating acute closed Achilles tendon rupture.

    Science.gov (United States)

    Ding, Wen-Ge; Li, Huan; Zhu, Ya-Ping; Liu, Zhi-wei

    2014-06-01

    To compare the effectiveness of tenocutaneous suture and conventional Kessler suture techniques in treating acute closed Achilles tendon rupture. A total of 33 patients with acute closed Achilles tendon rupture who were admitted to our hospital from February 1998 to December 2008 underwent repair with either a tenocutaneous suture or Kessler suture technique. All patients were followed up for 1-5 years (mean, 3 years). According to the American Orthopaedic Foot and Ankle Society ankle-hindfoot scale, the excellence rate was 91% in the Kessler suture group and 98% in the tenocutaneous suture group, with a significant difference between groups. Our tenocutaneous suture technique is an effective method for treating Achilles tendon rupture. It has certain advantages compared with the conventional incision method and is worthy of wide clinical application. Copyright © 2014 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  5. New adjustable suture technique for trabeculectomy

    Directory of Open Access Journals (Sweden)

    Vespasiano Rebouças-Santos

    2013-06-01

    Full Text Available PURPOSE: To describe an adjustable suture (AS experimental model that allows for tightening, loosening and retightening of the suture tension in trabeculectomy. METHODS: Standard trabeculectomy was performed in fifteen pig eyeballs. All pig eyes were tested twice: one test with conventional suture in both flap's corners (conventional suture group and another test with a conventional suture at one corner and an adjustable suture in the other corner (AS group. The order in which each test was performed was defined by randomization. Intraocular pressure was measured at three time points: T1 when the knots were tightened; T2 when the AS was loosened or the conventional knot was removed; and T3 when the AS was retightened in the AS group or five minutes after the knot removal in the conventional suture group. RESULTS: The mean Intraocular pressure was similar between the two groups at time point 1 (p=0.97. However, significant Intraocular pressure differences were found between eyes in the conventional and adjustable suture groups at time points 2 (12.6 ± 4.2 vs 16.3 ± 2.3 cmH2O, respectively, p=0.006 and 3 (12.2 ± 4.0 vs 26.4 ± 1.7cmH2O, respectively; p=0.001. While the conventional technique allowed only Intraocular pressure reduction (following the knot removal; T2 and T3, the AS technique allowed both Intraocular pressure reduction (T2 and elevation (T3 through the management (loosening and retightening of the suture. CONCLUSION: This experimental model provides an effective noninvasive postoperative mechanism of suture tension adjustment.

  6. Visibility of Sutures of the Orbit and Periorbital Region Using Multidetector Computed Tomography

    OpenAIRE

    2014-01-01

    Objective Knowledge of cranial suture morphology is crucial in emergency medicine, forensic medicine, and maxillofacial reconstructive surgery. This study assessed the visibility of sutures of the orbit and periorbital region on multidetector computed tomography. Materials and Methods Multidetector computed tomography scans of 200 patients (127 males, 73 females; mean age 51.3 years; range, 6-92 years) were evaluated retrospectively. The slice thicknesses varied from 0.5 to 1 mm, and the tube...

  7. Clinical Outcomes After Suture Anchor Repair of Recalcitrant Medial Epicondylitis.

    Science.gov (United States)

    Grawe, Brian M; Fabricant, Peter D; Chin, Christopher S; Allen, Answorth A; DePalma, Brian J; Dines, David M; Altchek, David W; Dines, Joshua S

    2016-01-01

    This study evaluated clinical and patient-reported outcomes and return to sport after surgical treatment of medial epicondylitis with suture anchor fixation. Consecutive patients were evaluated after undergoing debridement and suture anchor repair of the flexor-pronator mass for the treatment of medial epicondylitis. Demographic variables, a short version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH) score, Oxford Elbow Score (OES), and 10-point pain and satisfaction scales were collected. Ability and time to return to sport after surgery were evaluated, and the relationship between predictor variables and both elbow function and return to sport was investigated. Median age at the time of surgery was 55 years (range, 29-65 years), with median follow-up of 40 months (range, 12-67 months). Median QuickDASH score and OES at final follow-up were 2.3 (range, 0-38.6) and 45 (range, 22-48), respectively. Most patients returned to premorbid sporting activities at a median of 4.5 months (range, 2.5-12 months), whereas 4 patients (14%) reported significant limitations at final follow-up. Older age at the time of surgery was predictive of better QuickDASH score and OES (P=.05 and P=.02, respectively). Patients who underwent surgery after a shorter duration of symptoms had better outcomes, but the difference did not reach statistical significance (QuickDASH, P=.09; OES, P=.10). Surgical treatment of recalcitrant medial epicondylitis with suture anchor fixation offers good pain relief and patient satisfaction, with little residual disability. Older age at the time of surgery predicts a better outcome.

  8. Chronic complaints after simple sutured repair for umbilical or epigastric hernias may be related to recurrence

    DEFF Research Database (Denmark)

    Westen, Mikkel; Christoffersen, Mette W; Jorgensen, Lars N

    2014-01-01

    PURPOSE: Umbilical and epigastric hernia repairs are minor, but are commonly conducted surgical procedures. Long-term results have only been sparsely investigated. Our objective was to investigate the risk of chronic complaints after a simple sutured repair for small umbilical and epigastric...... hernias. METHODS: A retrospective cohort study with a 5-year questionnaire and clinical follow-up was conducted. Patients undergoing primary elective, open non-mesh umbilical or epigastric sutured hernia repair were included. Patients completed a structured questionnaire regarding chronic complaints...

  9. Development and evaluation of the e-learning teaching materials for surgical nursing training.

    Science.gov (United States)

    Matsuda, Yoshimi; Takeuchi, Tomiko; Takahashi, Yukiko; Ozawa, Kazuhiro; Nishimoto, Yutaka; Terauti, Hidemasa

    2006-01-01

    We investigated e-learning teaching materials with a questionnaire for 55 nursing students. Students thought the materials easy to use. In addition, the teaching materials which we developed gave them the confidence of thinking, "I can do it". We affect training by imaging a nursing procedure and think anxiety to training to be be relieved. However, load of PC became high in these teaching materials to display of two motion pictures simultaneously in one screen, so it would be necessary to produce the teaching materials considered transmission rate.

  10. Skin closure in vascular neurosurgery: A prospective study on absorbable intradermal suture versus nonabsorbable suture.

    Science.gov (United States)

    Pereira, Julio Leonardo Barbosa; Vieira, Gerival; de Albuquerque, Lucas Alverne Freitas; Mendes, George de Albuquerque Cavalcanti; Salles, Ludmila Rezende; de Souza, André Felipe Ferreira; Dellaretti, Marcos; de Sousa, Atos Alves

    2012-01-01

    The craniotomy performed with minimal hair removal and closure with intradermal suture alone is an option in neurosurgical procedures, which can help faster psychological recovery of the patient, as it allows a better cosmetic result. This study is aimed at evaluating if such method is safe and effective, compared with continuous skin sutures with 2-0 nylon. We analyzed the sutures in 117 patients undergoing craniotomies for cerebral aneurysm clipping. In the case group (n = 49), closure of the scalp was performed only with intradermal absorbable sutures using wire Monocryl(®) 2-0. In the control group (n = 68), closure was performed with continuous suture using 2-0 nylon. The case group was composed of 49 patients in whom just intradermal suture was performed. One (2.2%) patient developed wound infection and was given proper medical treatment. No cases of dehiscence or cerebrospinal fluid leaks were observed. The control group was composed of 68 patients in whom the skin was closed with 2-0 nylon continuous suture. Three (5.3%) patients developed wound infection and were given proper medical treatment. There were no cases of wound dehiscence. The overall infection rate in the control group was 4%. There was no statistically significant difference in the number of wound infections between the two groups (P = 0.73). The closure with intradermal suture alone in craniotomies is as safe as the traditional skin closure with nylon sutures, besides eliminating the need for suture removal and providing a cosmetic advantage.

  11. Influence of different length of core suture purchase among suture row on the strength of 6-strand tendon repairs.

    Science.gov (United States)

    Okubo, Hirotaka; Kusano, Nozomu; Kinjo, Masaki; Kanaya, Fuminori

    2015-01-01

    In multi-strand suture methods consisting of several suture rows, the different length of core suture purchase between each suture row may affect the strength of repairs. We evaluated the influence of the different length of core suture purchase between each suture row on the strength of 6-strand tendon repairs. Rabbit flexor tendons were repaired by using a triple-looped suture technique in which the suture purchase length in each suture row was modified. Group 1, all lengths are 8-mm. Group 2, all lengths are 10-mm. Group 3, two are 10-mm and one is 8-mm. Group 4, one is 10-mm and two are 8-mm. The repaired tendons were subjected to load-to-failure test. The gap strength was significantly greater in Group 1 and Group 2 than in Group 3 and Group 4. This study demonstrates that maintaining equal core suture purchase lengths of each suture row increases the gap resistance.

  12. Transeptal suturing - a cost-efficient alternative for nasal packing in septal surgery.

    Science.gov (United States)

    Plasencia, Daniel Pérez; Falcón, Juan Carlos; Barreiro, Silvia Borkoski; Bocanegra-Pérez, María Sacramento; Barrero, Mario Vicente; Macías, Ángel Ramos

    2016-01-01

    Nasal packing is routinely used in septal surgery to prevent postoperative bleeding. To demonstrate the possibility of transeptal suture as a safe and effective way to avoid nasal packing and to improve efficiency. This is a prospective, descriptive, inferential cost study comprising 92 patients. Two randomized groups of patients were analyzed, one with nasal packing and the other with transeptal suture. In the group of transeptal suture no patient experienced postoperative bleeding, and a statistically significant reduction of pain and headache was demonstrated. At the same time, we improved efficiency by saving on material costs. Transeptal suture is an effective and safe alternative to classic nasal packing in septal surgery. Moreover, it improves the efficiency of the intervention by saving costs. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  13. Transeptal suturing - a cost-efficient alternative for nasal packing in septal surgery

    Directory of Open Access Journals (Sweden)

    Daniel Pérez Plasencia

    Full Text Available ABSTRACT INTRODUCTION: Nasal packing is routinely used in septal surgery to prevent postoperative bleeding. OBJECTIVE: To demonstrate the possibility of transeptal suture as a safe and effective way to avoid nasal packing and to improve efficiency. METHODS: This is a prospective, descriptive, inferential cost study comprising 92 patients. Two randomized groups of patients were analyzed, one with nasal packing and the other with transeptal suture. RESULTS: In the group of transeptal suture no patient experienced postoperative bleeding, and a statistically significant reduction of pain and headache was demonstrated. At the same time, we improved efficiency by saving on material costs. CONCLUSIONS: Transeptal suture is an effective and safe alternative to classic nasal packing in septal surgery. Moreover, it improves the efficiency of the intervention by saving costs.

  14. Suture slippage in knotless suture anchors resulting in subacromial-subdeltoid bursitis.

    Science.gov (United States)

    Hayeri, Mohammad Reza; Keefe, Daniel T; Chang, Eric Y

    2016-05-01

    Rotator cuff repair using a suture bridge and knotless suture anchors is a relatively new, but increasingly used technique. The suture bridge technique creates an anatomically similar and more secure rotator cuff repair compared with conventional arthroscopic techniques and the use of knotless anchors eliminates the challenges associated with knot tying during arthroscopic surgery. However, previous in vitro biomechanical tests have shown that the hold of the suture in a knotless suture anchor is far lower than the pullout strength of the anchor from bone. Up until now slippage has been a theoretical concern. We present a prospectively diagnosed case of in vivo suture loosening after rotator cuff repair using a knotless bridge technique resulting in subacromial-subdeltoid bursitis.

  15. Skin closure in vascular neurosurgery: A prospective study on absorbable intradermal suture versus nonabsorbable suture

    OpenAIRE

    Pereira, Julio Leonardo Barbosa; Vieira,Gerival; de Albuquerque, Lucas Alverne Freitas; Mendes, George de Albuquerque Cavalcanti; Salles, Ludmila Rezende; de Souza, André Felipe Ferreira; Dellaretti, Marcos; Sousa,Atos Alves de

    2012-01-01

    Background: The craniotomy performed with minimal hair removal and closure with intradermal suture alone is an option in neurosurgical procedures, which can help faster psychological recovery of the patient, as it allows a better cosmetic result. This study is aimed at evaluating if such method is safe and effective, compared with continuous skin sutures with 2-0 nylon. Methods: We analyzed the sutures in 117 patients undergoing craniotomies for cerebral aneurysm clipping. In the case group (...

  16. Intravital imaging of the cellular dynamics of LysM-positive cells in a murine corneal suture model.

    Science.gov (United States)

    Ueta, Mayumi; Koga, Ayaka; Kikuta, Junichi; Yamada, Keiko; Kojima, Sachi; Shinomiya, Katsuhiko; Ishii, Masaru; Kinoshita, Shigeru

    2016-03-01

    Corneal suturing is a surgical procedure used in patients with corneal trauma or transplants. It was reported that endogenous neutrophils are brightly labelled in gene-targeted mice expressing enhanced green fluorescent protein (eGFP) under the control of the endogenous lysozyme M promoter (LysM-eGFP mice). We applied intravital imaging methods to analyse in vivo the dynamics of LysM-positive granulocytes (neutrophils) in LysM-eGFP mice with corneal sutures and examined their role in the elicitation of neutrophil infiltration. We found that in the presuturing state, neutrophils strongly positive for LysM were located in the periphery of the corneal stromal layer; none were present in the centre of the cornea. After introducing a corneal suture, neutrophils accumulated in limbal vessels and then migrated to the corneal side and the conjunctival side, suggesting that they derived from limbal vessels. Thereafter they accumulated towards the central corneal area, arriving at the suture about 7 h after its placement. Although corneal sutures may elicit the continuous infiltration of neutrophils, their number was markedly decreased by day 1 after suture removal and continued to decrease thereafter. Our results showed that corneal sutures may elicit the continuous infiltration of neutrophils. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  17. Strength of different meniscus suturing techniques.

    Science.gov (United States)

    Aşik, M; Sener, N; Akpinar, S; Durmaz, H; Göksan, A

    1997-01-01

    We measured and compared the primary stabilities of five different meniscal suturing techniques. The techniques tested were horizontal mattress, vertical mattress, knot-end, vertical, and vertical loop. Twenty bovine medial menisci were cut to simulate peripheral longitudinal tears and repaired with one of the five suture techniques. Then the two parts of the meniscus were pulled using the Instron Tensometer until failure occurred. Knot-end techniques gave inferior results (mean ultimate failure strength 64 +/- 5 N) compared with the other techniques. Vertical mattress failed at 130 +/- 3 N, vertical loop at 128 +/- 4.5 N, horizontal mattress at 98 +/- 5 N and vertical suturing at 136 +/- 2.7 N. This study shows the superior mechanical characteristic of the vertical suturing technique.

  18. A comparison of single-suture and double-suture incision closures in seaward-migrating juvenile Chinook salmon implanted with acoustic transmitters: implications for research in river basins containing hydropower structures

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Richard S.; Deters, Katherine A.; Cook, Katrina V.; Eppard, M. B.

    2013-07-15

    Reductions in the size of acoustic transmitters implanted in migrating juvenile salmonids have resulted in the ability to make shorter incisions that may warrant using only a single suture for closure. However, it is not known if one suture will sufficiently hold the incision closed, particularly when outward pressure is placed on the surgical site such as when migrating fish experience pressure changes associated with passage at hydroelectric dams. The objective of this research was to evaluate the effectiveness of single-suture incision closures on juvenile Chinook salmon (Oncorhynchus tshawytscha). Juvenile Chinook salmon were surgically implanted with a 2012 Juvenile Salmon Acoustic Telemetry System (JSATS) transmitter (0.30 g) and a passive integrated transponder tag (0.10 g) and incisions were closed with either one suture or two sutures. Mortality and tag retention were monitored and fish were examined after 7 and 14 days to evaluate tissue responses. In a separate experiment, surgically implanted fish were exposed to simulated turbine passage and then examined for expulsion of transmitters, expulsion of viscera through the incision, and mortal injury. With incisions closed using a single suture, there was no mortality or tag loss and similar or reduced tissue reaction compared to incisions closed with two sutures. Further, surgery time was significantly reduced when one suture was used, which leads to less handling and reduced stress. No tags were expelled during pressure scenarios and expulsion of viscera only occurred in two non-mortally injured fish (5%) with single sutures that were also exposed to very high pressure changes. No viscera expulsion was present in fish exposed to pressure scenarios likely representative of hydroturbine passage at many Columbia River dams (e.g. <2.7 ratio of pressure change; an acclimation pressure of 146.2 absolute kpa and a lowest exposure pressure of ~ 53.3 absolute kpa). Based on these results, we recommend the use of a

  19. Biomechanical analysis of suture locations of the distal plantar fascia in partial foot.

    Science.gov (United States)

    Guo, Jun-Chao; Wang, Li-Zhen; Mo, Zhong-Jun; Chen, Wei; Fan, Yu-Bo

    2015-12-01

    The aim of this study was to evaluate the rationality of the suture locations of distal plantar fascia (DPF) after foot amputation to avoid the risk factors of re-amputation or plantar fasciitis. The tensile strain of plantar fascia (PF) in the different regions was measured by uni-axial tensile experiment. A three-dimensional (3D) finite element model was also developed to simulate tensile behaviour of PF in weight bearing conditions. The model includes 12 bones, ligaments, PF, cartilage and soft tissues. Four suture location models for the DPF were considered: the fourth and fifth DPF were sutured on the third metatarsal, the cuboid, and both the third metatarsal and the cuboid, and one un-sutured model. The peak tensile strain of the first, second and third PF was 0.134, 0.128 and 0.138 based on the mechanical test, respectively. The fourth and fifth DPF sutured at the cuboid and the third metatarsal could offer more favourable outcomes. The peak strain of 4.859 × 10(-2), 2.347 × 10(-2) and 1.364 × 10(-2) in the first, second and third PF showed the least outcomes in stance phase. Also, peak strain and stress of the residual PF reduced to 4.859 × 10(-2) and 1.834 MPa, respectively. The stress region was redistributed on the mid-shaft of the first and third PF and the peak stress of medial cuneiform bone evidently decreased. The fourth and fifth DPF suture at the third metatarsal and cuboid was appropriate for the partial foot. The findings are expected to suggest optimal surgical plan of the DPF suture and guide further therapeutic planning of partial foot patients.

  20. Biodegradable materials for surgical management of infective endocarditis: new solution or a dead end street?

    Science.gov (United States)

    2014-01-01

    Background One third of patients with infective endocarditis will require operative intervention. Given the superiority of valve repair over valve replacement in many indications other than endocarditis, there has been increasing interest and an increasing number of reports of excellent results of valve repair in acute infective endocarditis. The theoretically ideal material for valve repair in this setting is non-permanent, “vanishing” material, not at risk of seeding or colonization. The goal of this contribution is to review currently available data on biodegradable materials for valve repair in infective endocarditis. Discussion Rigorous electronic and manual literature searches were conducted to identify reports of biodegradable materials for valve repair in infective endocarditis. Articles were identified in electronic database searches of Medline, Embase and the Cochrane Library, using a predetermined search strategy. 49 manuscripts were included in the review. Prosthetic materials needed for valve repair can be summarized into annuloplasty rings to remodel the mitral or tricuspid annulus, and patch materials to replace resected valvar tissue. The commercially available biodegradable annuloplasty ring has shown interesting clinical results in a single-center experience; however further data is required for validation and longer follow-up. Unmodified extra-cellular matrix patches, such as small intestinal submucosa, have had promising initial experimental and clinical results in non-infected valve repair, although in valve repair for endocarditis has been reported in only one patient, and concerns have been raised regarding their mechanical stability in an infected field. Summary These evolving biodegradable devices offer the potential for valve repair with degradable materials replaced with autologous tissue, which could further improve the results of valve repair for infective endocarditis. This is an evolving field with promising experimental or

  1. Adjustable versus non-adjustable suture techniques for concomitant horizontal strabismus: a comparative study

    Directory of Open Access Journals (Sweden)

    Galton C. Vasconcelos

    2015-12-01

    Full Text Available ABSTRACT Purpose: To compare the surgical results of adjustable and non-adjustable horizontal strabismus surgery for concomitant horizontal strabismus. Methods: The charts of 231 patients, who underwent horizontal strabismus surgery, selected using probabilistic sampling, were retrospectively reviewed. Patients were divided into two groups according to the surgical technique used and strabismus type. The adjustable suture technique was used for 107 patients (Group 1, and non-adjustable or conventional surgery was performed in the remaining 124 patients (Group 2. Patients with esotropia (ET or exotropia (XT of 5 PD, syndromes, restrictive or paretic strabismus, reoperations, botulinum toxin injection, and patients postoperatively followed up for 50% was present in all subgroups. Significant differences between strabismus groups submitted to adjustable technique and non-adjustable on postoperative day 1 were observed (p=0.00 for ET and p=0.01 for XT and at the last visit for the XT group with a follow-up of at least 1 year (p=0.05. Conclusion: The adjustable suture technique produced a higher success rate than non-adjustable strabismus surgery for both ET and XT groups on postoperative day 1. For XT patients, the adjustable suture technique appears to produce better surgical results than non-adjustable surgery, when the surgical goal is long-lasting maintenance of a small hypercorrection.

  2. The hidden X suture: a technical note on a novel suture technique for alveolar ridge preservation

    Science.gov (United States)

    2016-01-01

    Purpose The present study investigated the impact of 2 different suture techniques, the conventional crossed mattress suture (X suture) and the novel hidden X suture, for alveolar ridge preservation (ARP) with an open healing approach. Methods This study was a prospective randomized controlled clinical trial. Fourteen patients requiring extraction of the maxillary or mandibular posterior teeth were enrolled and allocated into 2 groups. After extraction, demineralized bovine bone matrix mixed with 10% collagen (DBBM-C) was grafted and the socket was covered by porcine collagen membrane in a double-layer fashion. No attempt to obtain primary closure was made. The hidden X suture and conventional X suture techniques were performed in the test and control groups, respectively. Cone-beam computed tomographic (CBCT) images were taken immediately after the graft procedure and before implant surgery 4 months later. Additionally, the change in the mucogingival junction (MGJ) position was measured and was compared after extraction, after suturing, and 4 months after the operation. Results All sites healed without any complications. Clinical evaluations showed that the MGJ line shifted to the lingual side immediately after the application of the X suture by 1.56±0.90 mm in the control group, while the application of the hidden X suture rather pushed the MGJ line slightly to the buccal side by 0.25±0.66 mm. It was demonstrated that the amount of keratinized tissue (KT) preserved on the buccal side was significantly greater in the hidden X suture group 4 months after the procedure (Pclinical and radiographic verification of the efficacy of the hidden X suture in preserving the width of KT and the dimensions of the alveolar ridge after ARP. PMID:28050319

  3. Functional implications of squamosal suture size in paranthropus boisei.

    Science.gov (United States)

    Dzialo, Christine; Wood, Sarah A; Berthaume, Michael; Smith, Amanda; Dumont, Elizabeth R; Benazzi, Stefano; Weber, Gerhard W; Strait, David S; Grosse, Ian R

    2014-02-01

    It has been hypothesized that the extensively overlapping temporal and parietal bones of the squamosal sutures in Paranthropus boisei are adaptations for withstanding loads associated with feeding. Finite element analysis (FEA) was used to investigate the biomechanical effects of suture size (i.e., the area of overlap between the temporal and parietal bones) on stress, strain energy, and strain ratio in the squamosal sutures of Pan troglodytes and P. boisei (specimen OH 5) during biting. Finite element models (FEMs) of OH 5 and a P. troglodytes cranium were constructed from CT scans. These models contain sutures that approximate the actual suture sizes preserved in both crania. The FEM of Pan was then modified to create two additional FEMs with squamosal sutures that are 50% smaller and 25% larger than those in the original model. Comparisons among the models test the effect of suture size on the structural integrity of the squamosal suture as the temporal squama and parietal bone move relative to each other during simulated premolar biting. Results indicate that with increasing suture size there is a decreased risk of suture failure, and that maximum stress values in the OH 5 suture were favorable compared to values in the Pan model with the normal suture size. Strain ratios suggest that shear is an important strain regime in the squamosal suture. This study is consistent with the hypothesis that larger sutures help reduce the likelihood of suture failure under high biting loads. Copyright © 2013 Wiley Periodicals, Inc.

  4. Operative treatment of acromioclavicular joint dislocation: a new technique with suture anchors

    Directory of Open Access Journals (Sweden)

    Zhang Jingwei

    2014-07-01

    Full Text Available 【Abstract】Objective: To evaluate clinical outcome of suture anchors in strengthening both acromioclavicular and coracoclavicular ligaments in the surgical treatment of acromioclavicular joint dislocation. Methods: Twenty-eight patients with acute traumatic Rockwood III, IV and V dislocations of the acromioclavicular joint surgically treated at our institute between October 2010 and January 2012 were recruited. All patients underwent open reduction combined with suture anchors. Function was evaluated using the ConstantMurley shoulder score. Clinical and radiographic shoulder ratings were evaluated using Taft criteria at 3, 6 and 12 months. Results:Two cases with fixation loosening were not included in final statistical analysis. Other patients obtained full joint reposition on immediate postoperative radiographs. Follow-up was performed with an average of 15.6 months (range, 12-19. After early range of motion exercises, 96.2% of the patients (25/26 could abduct and elevate their shoulders more than 90 degrees within postoperative 3 months. There was no infection. Average Constant-Murley score was 96.3 points (range, 94-100 and mean Taft shoulder rating was 10.7 points (range, 8-12 at 12 months. Conclusion: The suture anchor is a relatively simple technique and can avoid screw removal which is helpful in reconstructing both acromioclavicular and coracoclavicular ligaments in acute traumatic acromioclavicular joint dislocation. Key words: Acromioclavicular joint; Dislocations; Surgery; Suture anchors

  5. Keratometry device for surgical support

    Directory of Open Access Journals (Sweden)

    Saia Paula

    2009-12-01

    Full Text Available Abstract Background High astigmatisms are usually induced during corneal suturing subsequent to tissue transplantation or any other surgery which involves corneal suturing. One of the reasons is that the procedure is intimately dependent on the surgeon's skill for suturing identical stitches. In order to evaluate the influence of the irregularity on suturing for the residual astigmatism, a prototype for ophthalmic surgical support has been developed. The final intention of this prototype is to be an evaluation tool for guided suture and as an outcome diminish the postoperative astigmatism. Methods The system consists of hand held ring with 36 infrared LEDs, that is to be projected onto the lachrymal film of the cornea. The image is reflected back through the optics of the ocular microscope and its distortion from the original circular shape is evaluated by developed software. It provides keratometric and circularity measurements during surgery in order to guide the surgeon for uniformity in suturing. Results The system is able to provide up to 23D of astigmatism (32D - 55D range and is ± 0.25D accurate. It has been tested in 14 volunteer patients intraoperative and has been compared to a commercial keratometer Nidek Oculus Hand-held corneal topographer. The correlation factors are 0.92 for the astigmatism and 0.97 for the associated axis. Conclusion The system is potentially efficient for guiding the surgeon on uniformity of suturing, presenting preliminary data indicating an important decrease on the residual astigmatism, from an average of 8D - for patients not submitted to the prototype guidance - to 1.4D - for patients who have actually been submitted to the prototype guidance - after the first 24 hours post-surgery and in the subsequent weeks. It also indicates that the surgeon should achieve circularity greater or equal to 98% in order to avoid postoperative astigmatisms over 1D. Trial Registration Trial registration number: CAAE - 0212.0.004.000-09.

  6. A single centre comparative study of laparoscopic mesh rectopexy versus suture rectopexy

    Directory of Open Access Journals (Sweden)

    Manash Ranjan Sahoo

    2014-01-01

    Full Text Available Aim: The aim of our study is to compare the results of laparoscopic mesh vs. suture rectopexy. Materials and Methods: In this retrospective study, 70 patients including both male and female of age ranging between 20 years and 65 years (mean 42.5 yrs were subjected to laparoscopic rectopexy during the period between March 2007 and June 2012, of which 38 patients underwent laparoscopic mesh rectopexy and 32 patients laparoscopic suture rectopexy. These patients were followed up for a mean period of 12 months assessing first bowel movement, hospital stay, duration of surgery, faecal incontinence, constipation, recurrence and morbidity. Results: Duration of surgery was 100.8 ± 12.4 minutes in laparoscopic suture rectopexy and 120 ± 10.8 min in laparoscopic mesh rectopexy. Postoperatively, the mean time for the first bowel movement was 38 hrs and 40 hrs, respectively, for suture and mesh rectopexy. Mean hospital stay was five (range: 4-7 days. There was no significant postoperative complication except for one port site infection in mesh rectopexy group. Patients who had varying degree of incontinence preoperatively showed improvement after surgery. Eleven out of 18 (61.1% patients who underwent laparoscopic suture rectopexy as compared to nine of 19 (47.3% patients who underwent laparoscopic mesh rectopexy improved as regards constipation after surgery. Conclusion: There were no significant difference in both groups who underwent surgery except for patients undergoing suture rectopexy had better symptomatic improvement of continence and constipation. Also, cost of mesh used in laparoscopic mesh rectopexy is absent in lap suture rectopexy group. To conclude that laparoscopic suture rectopexy is a safe and feasible procedure and have comparable results as regards operative time, morbidity, bowel function, cost and recurrence or even slightly better results than mesh rectopexy.

  7. Evaluation of absorbable and nonabsorbable sutures for repair of achilles tendon rupture with a suture-guiding device.

    Science.gov (United States)

    Kocaoglu, Baris; Ulku, Tekin Kerem; Gereli, Arel; Karahan, Mustafa; Turkmen, Metin

    2015-06-01

    The purpose of this study was to compare the functional and clinical results of Achilles tendon repairs with an Achilles tendon suture-guiding device using nonabsorbable versus absorbable sutures. We hypothesized that the absorbable suture would have clinical results comparable to those of the nonabsorbable suture for Achilles tendon repair with an Achilles tendon suture-guiding system. From January 2010 to September 2013, 48 consecutive patients who had sustained a spontaneous rupture of the Achilles tendon underwent operative repair with an Achilles tendon suture-guiding device using 2 different suture types. All ruptures were acute. The patients were divided equally into 2 groups according to suture type. In the nonabsorbable suture group, No. 2 braided nonabsorbable polyethylene terephthalate sutures were used, and in the absorbable suture group, braided absorbable polyglactin sutures were used. The average age of the patients was 38 years (range, 28-50 years). Functional outcome scores and complications were evaluated. All patients had an intact Achilles repair after surgery. The American Orthopaedic Foot & Ankle Society (AOFAS) hindfoot clinical outcome scores were 98 (range, 90-100) in the nonabsorbable suture group and 96.8 (range, 87-100) in the absorbable suture group. All patients returned to their previous work. The absorbable suture group had fewer postoperative complications (0%) than the nonabsorbable suture group (12.5%) (P Achilles tendon repair by an Achilles tendon suture-guiding system was associated with a lower incidence of suture reaction; however, functionally the results were not notably different from those using a traditional nonabsorbable suture. We conclude that repair with absorbable sutures is appropriate for Achilles tendon ruptures. Level II, prospective comparative study. © The Author(s) 2015.

  8. Modified method for bronchial suture by Ramirez Gama compared to separate stitches suture: experimental study

    Directory of Open Access Journals (Sweden)

    Vitor Mayer de Moura

    Full Text Available OBJECTIVE: To experimentally compare two classic techniques described for manual suture of the bronchial stump. METHODS: We used organs of pigs, with isolated trachea and lungs, preserved by refrigeration. We dissected 30 bronchi, which were divided into three groups of ten bronchi each, of 3mm, 5mm, and 7mm, respectively. In each, we performed the suture with simple, separated, extramucosal stitches in five other bronchi, and the technique proposed by Ramirez and modified by Santos et al in the other five. Once the sutures were finished, the anastomoses were tested using compressed air ventilation, applying an endotracheal pressure of 20mmHg. RESULTS: the Ramirez Gama suture was more effective in the bronchi of 3, 5 and 7 mm, and there was no air leak even after subjecting them to a tracheal pressure of 20mmHg. The simple interrupted sutures were less effective, with extravasation in six of the 15 tested bronchi, especially in the angles of the sutures. These figures were not significant (p = 0.08. CONCLUSION: manual sutures of the bronchial stumps were more effective when the modified Ramirez Gama suture was used in the caliber bronchi arms when tested with increased endotracheal pressure.

  9. Surgical management of neuroblastoma-related hepatomegaly: do material and method really count?

    Science.gov (United States)

    Harper, L; Perel, Y; Lavrand, F; Brissaud, O

    2008-06-01

    The authors report 2 cases of neuroblastoma-associated hepatomegaly, which were treated using a Silastic patch, and discuss in the light of recent reports, the technical aspects and outcome of these children. They were satisfied by the decompression achieved with the patch and believe there is no increased risk in using Silastic rather than other types of material. The outcome for these children depends more on the evolution of the underlying disease than the technical aspects of the abdominal decompression.

  10. Needle Grasp and Entry Port Selection for Automatic Execution of Suturing Tasks in Robotic Minimally Invasive Surgery

    Science.gov (United States)

    Liu, Taoming; Çavuşoğlu, M. Cenk

    2016-01-01

    This paper presents algorithms for selection of needle grasp and for selection of entry ports of robotic instruments, for autonomous robotic execution of the minimally invasive surgical suturing task. A critical issue for automatic execution of surgical tasks, such as suturing, is the choice of needle grasp for the robotic system. Inappropriate needle grasp increases operating time requiring multiple regrasps to complete the desired task. In robotic minimally invasive surgery, the entry port that the surgical robot goes through into the patient’s body has a significant role on the performance of the robot. Improper entry port affects the robot’s dexterity, manipulability and reachability. The proposed methods use manipulability, dexterity and torque metrics for needle grasp selection, and employ needle grasp robustness and target location robustness metrics for port selection. The results of a case study simulation in thoracoscopic surgery is also presented to demonstrate the proposed methods. Note to Practitioners—This paper is motivated by the problem of automating low-level surgical tasks in robotic surgery, such as, suturing, retraction, dissection, and providing exposure. Specifically, this paper focuses on needle grasp and entry port selection for automating robotic surgical suturing. Selection of an appropriate way of grasping a needle is critical for successfully and robustly completing autonomous suturing. To the best authors’ knowledge, there are no earlier studies in the literature which focus on the needle grasp selection problem. The proposed approach determines how to grasp the needle by optimizing the surgical system’s manipulation performance. The existing approaches in the literature for selecting entry ports for the robotic surgical tools only consider the teleoperated robotic minimally invasive surgery, in which the surgeons directly control the robotic instruments. However, automated performance of suturing introduces additional

  11. Teflon-buttressed sutures plus pericardium patch repair left ventricular rupture caused by radiofrequency catheter ablation

    Science.gov (United States)

    Cao, Hao; Zhang, Qi; He, Yanzhong; Feng, Xiaodong; Liu, Zhongmin

    2016-01-01

    Abstract Background: Cardiac rupture often occurs after myocardial infarction or chest trauma with a high mortality rate. However, left ventricular rupture caused by radiofrequency catheter ablation (RFCA) is extremely rare. Methods: We describe a case of a 61-year-old male who survived from left ventricular rupture caused by a RFCA procedure for frequent ventricular premature contractions. Surgical exploration with cardiopulmonary bypass (CPB) was performed when the signs of cardiac tamponade developed 7 hours after the ablation surgery. Results: Teflon-buttressed sutures of the tear in the left ventricular posterolateral wall and pericardium patch applied to the contusion region on the wall repaired the rupture safely and effectively. Conclusion: Timely surgical intervention under CPB facilitated the survival of the patient. Teflon-buttressed sutures plus pericardium patch achieved the successful repair of the rupture. PMID:27661047

  12. Facial thread lifting with suture suspension.

    Science.gov (United States)

    Tavares, Joana de Pinho; Oliveira, Carlos Augusto Costa Pires; Torres, Rodolfo Prado; Bahmad, Fayez

    2017-05-09

    The increased interest in minimally-invasive treatments, such as the thread lifting, with lower risk of complications, minimum length of time away from work and effectiveness in correcting ptosis and aging characteristics has led many specialists to adopt this technique, but many doubts about its safety and effectiveness still limit its overall use. To analyze data published in the literature on the durability of results, their effectiveness, safety, and risk of serious adverse events associated with procedures using several types of threading sutures. Literature review using the key words "thread lift", "barbed suture", "suture suspension" and "APTOS". Due to the scarcity of literature, recent reports of facial lifting using threads were also selected, complemented with bibliographical references. The first outcomes of facial lifting with barbed sutures remain inconclusive. Adverse events may occur, although they are mostly minor, self-limiting, and short-lived. The data on the maximum effect of the correction, the durability of results, and the consequences of the long-term suture stay are yet to be clarified. Interest in thread lifting is currently high, but this review suggests that it should not yet be adopted as an alternative to rhytidectomy. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  13. Suture placement near the musculotendinous junction in the supraspinatus: implications for rotator cuff repair.

    Science.gov (United States)

    Kullar, Raj S; Reagan, Jeffrey M; Kolz, Christopher W; Burks, Robert T; Henninger, Heath B

    2015-01-01

    Transosseous-equivalent rotator cuff repair has an increased incidence of medial rotator cuff failure compared with single-row repair. No studies have evaluated the influence of the proximity of the suture row to the musculotendinous junction (MTJ) on cyclic gapping and failure properties. A single row of horizontal mattress sutures placed within the supraspinatus tendon lateral to the MTJ will experience less gap formation and higher failure loads than a similar suture row placed at the MTJ. Controlled laboratory study. Paired supraspinatus tendons were isolated from human cadaveric specimens and resected at the tendon insertion to the humerus. Randomized within a pair, a single row of 4 horizontal mattress sutures was placed either in the tendon 5 mm lateral to the MTJ or at the MTJ. The tied sutures secured the tendon to a fixture that ensured consistent placement of the suture row in the tendon and static fixation of the row. The muscle belly was gripped in a cryoclamp, and a servohydraulic materials testing machine was used to provide uniaxial tensile deformation for 500 cycles at 1 Hz, followed by load to failure at 1 mm/s. Fiducial markers with video tracking were used to quantify gap formation at the suture line, while the materials testing machine recorded loading for the cyclic and failure tests. During cyclic loading, both constructs experienced gross initial gap formation, followed by progressive gap formation that plateaued after cycle 200. The MTJ specimens had significantly higher mean cumulative gapping than the tendon specimens: 3.6±1.0 mm versus 2.4±0.6 mm, respectively (P=.012). The tendon specimens had significantly higher mean loads to failure than did the MTJ specimens: 567.1±121.8 N versus 434.2±148.1 N, respectively (P=.013). The mean failure displacement did not differ between groups for the tendon and MTJ: 5.7±2.5 mm versus 4.5±2.0 mm, respectively (P=.144). A horizontal suture row placed at the MTJ has inferior mechanical properties

  14. Patella fracture fixation with suture and wire: you reap what you sew.

    Science.gov (United States)

    Egol, Kenneth; Howard, Daniel; Monroy, Alexa; Crespo, Alexander; Tejwani, Nirmal; Davidovitch, Roy

    2014-01-01

    Operative fixation of displaced inferior pole patella fractures has now become the standard of care. This study aims to quantify clinical, radiographic and functional outcomes, as well as identify complications in a cohort of patients treated with non-absorbable braided suture fixation for inferior pole patellar fractures. These patients were then compared to a control group of patients treated for mid-pole fractures with K-wires or cannulated screws with tension band wiring. In this IRB approved study, we identified a cohort of patients who were diagnosed and treated surgically for a displaced patella fracture. Demographic, injury, and surgical information were recorded. All patients were treated with a standard surgical technique utilizing non-absorbable braided suture woven through the patellar tendon and placed through drill holes to achieve reduction and fracture fixation. All patients were treated with a similar post-operative protocol and followed up at standard intervals. Data were collected concurrently at follow up visits. For purpose of comparison, we identified a control cohort with middle third patella fractures treated with either k-wires or cannulated screws and tension band technique. Patients were followed by the treating surgeon at regular follow-up intervals. Outcomes included self-reported function and knee range of motion compared to the uninjured side. Forty-nine patients with 49 patella fractures identified retrospectively were treated over 9 years. This cohort consisted of 31 females (63.3%) and 18 males (36.7%) with an average age of 57.1 years (range 26-88 years). Patients had an average BMI of 26.48 (range 19-44.08). Thirteen patients with inferior pole fractures underwent suture fixation and 36 patients with mid-pole fractures underwent tension band fixation (K-wire or cannulated screws with tension band). In the suture cohort, one fracture failed open repair (7.6%), which was revised again with sutures and progressed to union. Of the 36

  15. [Refixation of sternoclavicular luxation with a suture anchor system].

    Science.gov (United States)

    Lehmann, W; Laskowski, J; Grossterlinden, L; Rueger, J M

    2010-05-01

    Luxations of the sternoclavicular joint are rare injuries. We present a case of anterior dislocation which was caused by a minor fall onto the right shoulder. Diagnosis was delayed by 2 weeks which prevented treatment by closed reduction. As an alternative surgical treatment a PDS cord around the clavicle and the first rib was used to stabilize the clavicle at the vertical level. Subsequently, fixation to the medial side was achieved by a suture anchor that was placed into the manubrium. The presented case highlights this simple and safe method to treat dislocations of the sternoclavicular joint in which standard treatment cannot be performed. A detailed description for each operation step is given and our experience in terms of aftercare and outcome is reported.

  16. Side-to-side anastomosis using 4 interrupted sutures in small coronary arteries.

    Science.gov (United States)

    Kawahito, Koji; Muraoka, Arata; Misawa, Yoshio

    2014-01-01

    Side-to-side anastomosis in sequential bypass grafting of coronary arteries 1.0 mm in diameter or smaller, requires delicate surgical techniques with a high degree of technical difficulty. However, using only 4 interrupted sutures, we have performed side-to-side anastomosis in sequential grafting without difficulty in a short operative duration. We applied this technique in 58 distal anastomosis procedures, achieving an early angiographic graft patency rate of 100%.

  17. Cauterization technique for suture erosion in transscleralfixation of intraocular lenses

    Directory of Open Access Journals (Sweden)

    Xu-Ting Hu

    2013-12-01

    Full Text Available Transscleral suturing is a commonly applied technique to fix intraocular implants in the sulcus. A major problem after transscleral implantation is suture erosion that normally happens in the late post-surgery period and may result in an increased incidence of endophthalmitis. Here we describe an original cauterization method by using a glass rod to melt the exposed suture end without damaging the suture knot in the sclera to avoid suture exposure in sclera-fixed IOL implantation. This is a simple, quick and effective technique that can be performed without conjunctiva incisions and will help to reduce suture erosion related complications.

  18. [Percutaneus Suture of Achilles Tendon Rupture--Operation for Beginners?].

    Science.gov (United States)

    Prokop, A; Dolezych, R; Chmielnicki, M

    2016-02-01

    Acute rupture of the Achilles tendon is the most common tendon injury, with an incidence of 30/100,000 population. With the Dresden instruments, operative tendon suture can be standardised and is safe, quick and minimally invasive. With post-operative functional therapy in a walking boot, very good clinical results can be achieved. Is this operation suitable as an educational procedure and is its performance still economic? Between 1 January 2007 and 31 December 2013, 212 patients with acute rupture of the Achilles tendon were operated using the Dresden instruments. There were 167 males and 45 females, with an average age of 46 years. 99 operations were performed by trainees, 46 by attending surgical staff, and 57 by a senior surgeon. With the trainees, the mean duration of the operation was 29:53 minutes, and with the attending staff 29:10 minutes (n. s., p > 0.1). The rate of complications (re-rupture, infection, and sural nerve damage) was 5/99 (5 %) for the trainees, 4/46 (8.7 %) for the attending staff, and 3/57 (5.3 %) for the senior surgeon. A total cost analysis yielded a total operative cost of 445.76 € for outpatient surgery. With a billed sum of 490.11 €, net income of 44.35 € per case is generated. In patients with reasonable indications for 2-day short inpatient treatment, total treatment cost was 3232.70 €. Percutaneous suture of the Achilles tendon with the Dresden instruments is a standardised and cost-effective surgical procedure. It is suitable as a "beginner's" procedure that can be performed quickly, safely, and cost-effectively. Georg Thieme Verlag KG Stuttgart · New York.

  19. Allergy to Prolene Sutures in a Dural Graft for Chiari Decompression

    Directory of Open Access Journals (Sweden)

    Iahn Cajigas

    2015-01-01

    Full Text Available Allergy to Prolene suture is exceedingly rare with only 5 cases reported in the literature. There have been no such cases associated with neurosurgical procedures. Diagnosis is nearly always delayed in spite of persistent symptomatology. A 27-year-old girl with suspected Ehlers-Danlos, connective tissue disorder, underwent posterior fossa decompression for Chiari Type 1 malformation. One year later, the patient presented with urticarial rash from the neck to chest. Cerebrospinal fluid and blood testing, magnetic resonance imaging, and intraoperative exploration did not suggest allergic reaction. Eventually skin testing proved specific Prolene allergy. After suture material was removed, the patient no longer complained of pruritus or rash. This single case highlights the important entity of allergic reaction to suture material, namely, Prolene, which can present in a delayed basis. Symptomatology can be vague but has typical allergic characteristics. Multidisciplinary approach is helpful with confirmatory skin testing as a vital part of the workup.

  20. Upper lid crease approach for margin rotation in trachomatous cicatricial entropion without external sutures

    Directory of Open Access Journals (Sweden)

    Antonio Augusto Velasco e Cruz

    2015-12-01

    Full Text Available ABSTRACT Purpose: To describe the use of a lid crease incision for upper eyelid margin rotation in cicatricial entropion combining internal traction on the anterior lamella, tarsotomy, and tarsal overlap without external sutures. Methods: Surgical description: The main steps of the procedure consisted of exposure of the entire tarsal plate up to the eyelashes followed by tarsotomy through the conjunctiva. A double-armed 6.0 polyglactin suture was then passed through the distal tarsal fragment to the marginal section of the orbicularis oculi muscle. As the sutures were tied, the distal tarsus advanced over the marginal section, and traction was exerted on the marginal strip of the orbicularis muscle. There were no bolsters or external knots. The pretarsal skin-muscle flap was closed with a 6.0 plain gut suture. Results: We used this procedure at a tertiary hospital in Saudi Arabia from 2013 to 2014. Sixty upper lids of 40 patients (23 women and 17 men were operated on, with an age range of 44-99 years [mean ± standard deviation (SD = 70.9 ± 13.01 years]. Bilateral surgery was performed on 21 patients. Follow-up ranged from 1 to 12 months (mean 3.0 ± 2.71 months. Forty percent of the patients (24 lids had more than 3 months' follow-up. The postoperative lid margin position was good in all cases. Trichiasis (two lashes was observed in only one patient with unilateral entropion on the medial aspect of the operated lid. Conclusions: The upper lid margin can be effectively rotated through a lid crease incision with internal sutures. The technique combines the main mechanisms of the Wies and Trabut approaches and avoids the use of bolsters or external sutures, which require a second consultation to be removed. Some other lid problems, such as ptosis, retraction, or dermatochalasis, can be concomitantly addressed during the procedure.

  1. Transcutaneous Serdev Suture For Buttock’s Lift

    Directory of Open Access Journals (Sweden)

    Nikolay Serdev

    2012-10-01

    Full Text Available This article presents the author's technique and experience in the treatment of the flaccid "unhappy buttock" form with his surgical procedure of buttock lift by suture, without incision scars. The author first presented this new operation technique on a national level at the 2nd Annual Meeting of the National Bulgarian Society for Aesthetic Surgery and Aesthetic Medicine in Sofia on March 18, 1994 [1] and internationally at many scientific meetings over the world [2, 3, 4…]. The result is a visual change in the buttock position to a higher one, which elongates the lower limbs and changes the proportions between lower and upper half of the body. The aim of this study is to describe a mini-invasive procedure of beautification of the buttock form without scars by creating a lifting effect on the buttock's subcutaneous tissue, using a suture that takes the inferiorly positioned deep fibrose tissue and fixes it upwards to the sacro-cutaneous fascia, discovered by the author. Aesthetic and technical considerations required properly sculpting the buttocks into a higher position, demonstrating nicely rounded form. Preoperative shape is discussed and patient evaluations, operative techniques, postoperative management and results after 4 years of experience are emphasized. 1032 female patients, and 26 male patients aged 18-62 years, with ptosis and cellulite on the buttocks were treated since 1993 on an outpatient basis by the "Serdev suture technique without visible scars". Important instrumentarium is a long, curved, elastic needle and Polycon semi-elastic Bulgarian antimicrobial polycaproamide long term (in 2 years absorbable surgical threads Polycon, produced in Bulgaria. This operation has been performed either alone or after ultrasonic assisted liposculpture (UAL that reduces the amount of fat and heaviness. All patients reported a high degree of satisfaction. A stable improvement in the buttock position and form was observed for the period

  2. The Gore-Tex Suture in Periareolar Closure: A Modified Closure Technique.

    Science.gov (United States)

    Chapman, Jade; Ingram, Scott

    2016-12-01

    In breast reduction and mastopexy procedures, the periareolar closure forms a vital component of the surgery. Periareolar closures completed with an absorbable suture may be prone to significant widening, hypertrophy and/or areolar distortion. In an effort to avoid this, some surgeons use a non-absorbable/permanent suture material [Franco (Arch Plast Surg 41 (6): 728-733, 2014)]. Hammond (Plast Reconstr Surg 119 (3):804-809, 2007) recommends the use of a Gore-Tex® suture for this purpose in view of the supple, pliable nature of the material; however, there remain at least occasional instances of infection and extrusion of the knot used to tie off the Gore-Tex "purse-string" [Franco (Arch Plast Surg 41 (6): 728-733, 2014); Salgarello (Aesthet Plast Surg 37 (5):1061-1062, 2013)]. We describe a method of securing the suture ends, which avoids the creation of a bulky knot, thus minimising the risk of infection and suture extrusion. Level of Evidence V This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  3. A novel technique for chest drain removal using a two layer method with triclosan-coated sutures

    Science.gov (United States)

    Yokoyama, Yujiro; Nakagomi, Takahiro; Shikata, Daichi

    2017-01-01

    In thoracic surgery, a thoracic drain is always inserted after the surgical procedure. Repair of the wound after removal of the thoracic tube is performed postoperatively, but no universally standard methods currently exists for this tube removal. Here we report a technique using triclosan-coated sutures that is used in thoracic surgery in our hospital. There are several advantages of this technique. First, there is no need for stitches removal on follow-up. Second, it prevents the leakage of pleural exudate because of the tight two-layer sutures. In addition, it was observed to be superior in terms of both wound healing and cosmetic aspects, due to the layer-to-layer sutures. The use of triclosan-coated sutures helps prevent infection and empyema is quite unlikely to occur as the result of the tight ligating of the muscular layer using these sutures. We applied this method in 168 patients over a period of 24 months. There were no complications on removal of the chest tube such as infection, fluid leakage or opening of the surgical wound. PMID:28203426

  4. Effect of the suture technique on postoperative pain, swelling and trismus after removal of lower third molars: A randomized clinical trial.

    Science.gov (United States)

    Gay-Escoda, Cosme; Gómez-Santos, Laila; Sánchez-Torres, Alba; Herráez-Vilas, José-María

    2015-05-01

    To evaluate the intensity of pain, swelling and trismus after the removal of impacted lower third molars comparing two different suture techniques of the triangular flap: the complete suture of the distal incision and relieving incision and the partial suture with only one suture knot for closure of the corner of the flap and the closure of the distal incision, without suturing the relieving incision. A prospective, randomized, cross-over clinical trial was conducted in 40 patients aged from 18 to 45 years who underwent surgical extraction of impacted lower third molars at the Department of Oral Surgery in the Odontological Hospital of the University of Barcelona during the year 2011. Patients were randomly divided in 2 groups. Two different techniques (hermetical closure and partial closure of the wound) were performed separated by a one month washout period in each patient. Postoperative pain, swelling and trismus were evaluated prior to the surgical procedure and also at 2 and 7 days postoperatively. No statistically significant differences were observed for pain (ptrismus (p<0.71) and swelling (p<0.05) between the test and the control group. However, the values of the three parameters related to the test group were lower than those for the control group. Partial closure of the flap without suturing the relieving incision after surgical extraction of lower third molars reduces operating time and it does not produce any postoperative complications compared with complete closure of the wound.

  5. Healing of intraoral wounds closed using silk sutures and isoamyl 2-cyanoacrylate glue: a comparative clinical and histologic study.

    Science.gov (United States)

    Vastani, Ankita; Maria, Anisha

    2013-02-01

    To compare the clinical and histologic healing of intraoral wounds closed using No. 3-0 silk suture with that obtained with isoamyl 2-cyanoacrylate glue. We performed alveoloplasty in 30 cases in the mandibular anterior region of edentulous arches; the length of incision in all cases was the same distance from the midline. The closure was performed on 1 side with No. 3-0 silk suture, and the other side was closed with isoamyl 2-cyanoacrylate. The surgical sites were evaluated on the first, seventh, fourteenth, and twenty-first postoperative days for tenderness and erythema. In 15 cases (group A), incisional biopsies on both sutured and glued sides were performed on the seventh postoperative day. In the other 15 patients, similar biopsies were executed on the fourteenth postoperative day (group B). All specimens were examined under a microscope for inflammatory cell infiltration, vascularity, and fibroblastic activity. The incidence of tenderness and erythema was increased on the sutured side on the first, seventh, and fourteenth postoperative days but was similar to that on the glued side on the twenty-first postoperative day. In the patients biopsied on the seventh postoperative day, values of inflammatory cell infiltration and vascularity were higher on the sutured side, whereas in patients biopsied on the fourteenth postoperative day, only vascularity was higher on the sutured side. On the seventh postoperative day, both clinical and histologic indicators of inflammation were higher on the sutured side, but these indicators had reached similar values on the fourteenth postoperative day on both the sutured and glued sides. This suggests that isoamyl 2-cyanoacrylate may aid initial healing. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Sutura intestinal monoplano extramucosa, discontinua, a bordes invertidos: Su aplicación en 22 años Discontinuos extramucosal single layer intestinal suture on reversed edges: Application of this technique for 22 years

    Directory of Open Access Journals (Sweden)

    José Miguel Pérez Morales

    2007-06-01

    Full Text Available Durante el período de enero de 1982 a diciembre del 2004 se aplicó la sutura intestinal monoplano extramucosa, discontinua y a bordes invertidos (SIMEDI en 580 pacientes con 25 enfermedades del tubo digestivo. El estudio fue prospectivo, analítico y descriptivo. La técnica se aplicó 703 veces porque hubo pacientes con más de una sutura y se empleó solamente en segmentos intestinales con serosa. Se realizaron 463 anastomosis, 171 enterorrafias y 69 cierres de un extremo intestinal. Se operaron 373 pacientes de forma programada y 207 pacientes, de urgencia. Hubo 85 pacientes que presentaron complicaciones, 13 de las cuales eran dependientes de la técnica y 72, no dependientes de ella. Las complicaciones dependientes fueron 12 dehiscencias de suturas y 1 estenosis. La combinación anastomótica término-lateral más latero-lateral y cierre de un extremo intestinal fue la que más complicaciones presentó. La neoplasia maligna gástrica y de colon derecho fueron las enfermedades con más complicaciones dependientes. Se ahorró material de sutura. La SIMEDI constituye una buena opción en la cirugía del tubo digestivosummary In the period from January 1982 to December 2004, discontinuos extramucosal single layer intestinal suture on reversed edges was performed in 580 patients who had presented with 25 diseases of the digestive tract. A prospective, analytical and descriptive study was conducted. The technique was applied 703 times because there were patients with more than one suture and it was used only in intestinal segments with serose. Four hundred and sixty three anastomoses, 171 enterorrhaphies and 69 closures of an intestinal end were performed. Three hundred and seventy three patients were scheduled to be operated on whereas 207 patients were operated on due to emergency situation. There were 85 patients who developed complications, 13 had surgical technique-depending complications and 72 did not. Depending complications covered 12

  7. Global Surgical Ecosystems: A Need for Systems Strengthening.

    Science.gov (United States)

    deVries, Catherine R; Rosenberg, Jenna S

    As surgery is gaining recognition as a critical component of universal health care worldwide, surgical communities have come together with unprecedented unity to advocate for systems to support surgical care. This community has long believed that much care could be performed in a cost-effective manner even in low resource settings, despite skepticism voiced by many in public health. To do so will require the development of new systems and re-vamping of old systems that are not effective. In the last five years, coalitions, expert panels, commissions, consortia and alliances have emerged to address these issues and there has been landmark success in advocacy with a new resolution at the 2015 World Health Assembly to include surgical care as a component of universal health coverage. It is critical to understand the ecosystem that constitutes the surgical environment. A surgical ecosystem could be described as a network of people, processes, and materials necessary for surgical services in the context of the facilities and environment in which it functions. We describe components of a functioning surgical ecosystem in terms of administration, support staff and clinicians, and the necessary sub-systems for providing consumable materials such as anesthetic medication and suture and sterile instruments. Related systems that must be integrated are facilities and utilities such as electricity, lighting, plumbing and waste management and even laundry. But especially in low and middle income countries (LMICs) lack of any one of these may be rate-limiting. The World Health Organization (WHO) has developed situational analyses and checklists for first level district hospitals to identify missing elements. A siloed approach cannot solve a systems problem. However, to scale up rapidly and to develop and sustain quality standards, a holistic "ecosystem" approach, including local and global professional societies and advocacy organizations will need to become engaged. Copyright

  8. Comparison of suture types in the closure of scalp wounds.

    LENUS (Irish Health Repository)

    Bonham, Joseph

    2011-06-01

    Innovation in practice can benefit patients and healthcare providers but must be evidence based. This article describes a quantitative study of whether absorbable sutures are as beneficial as non-absorbable sutures in the management of simple scalp lacerations in adults. The results suggest that absorbable sutures can provide the same cosmetic and functional results as non-absorbable sutures. Their use can also reduce patient returns and save money and resources.

  9. Barbed sutures in general and digestive surgery. Review.

    Science.gov (United States)

    Ferrer-Márquez, Manuel; Belda-Lozano, Ricardo

    2016-02-01

    The appearance of new barbed sutures is an advance in making knots and anastomosis, mainly in laparoscopic surgery, where the majority of the surgeons find themselves limited dealing with these sutures. Through this review we aim to evaluate both the use and the safety of the sutures in General and Laparoscopic Surgery. Barbed sutures seem to ease the procedures improving key aspects such as reproducibility and operative time.

  10. The red-eared slider turtle carapace under fatigue loading: The effect of rib-suture arrangement.

    Science.gov (United States)

    Achrai, Ben; Daniel Wagner, H

    2015-08-01

    Biological structures consisting of strong boney elements interconnected by compliant but tough collagenous sutures are abundantly found in skulls and shells of, among others, armadillos, alligators, turtles and more. In the turtle shell, a unique arrangement of alternating rigid (rib) and flexible (suture) elements gives rise to superior mechanical performance when subjected to low and high strain-rate loadings. However, the resistance to repeated load cycling - fatigue - of the turtle shell has yet to be examined. Such repeated loading could approximately simulate the consecutive high-stress bending loads exerted during (a predator) biting or clawing. In the present study flexural high-stress cyclic loads were applied to rib and suture specimens, taken from the top dorsal part of the red-eared slider turtle shell, termed carapace. Subsequently, to obtain a more complete and integrated fatigue behavior of the carapace, specimens containing a complex alternating rib-suture-rib-suture-rib configuration were tested as well. Although the sutures were found to be the least resistant to repeated loads, a synergistic effect was observed for the complex specimens, displaying improved fatigue durability compared to the individual (suture or even rib) constituents. This study may assist in the design of future high-stress fatigue-resistant materials incorporating complex assemblies of rigid and flexible elements. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Non-suture methods of vascular anastomosis

    NARCIS (Netherlands)

    Zeebregts, CJ; Heijmen, RH; van den Dungen, JJ; van Schilfgaarde, R

    2003-01-01

    Background: The main aim of performing a vascular anastomosis is to achieve maximal patency rates. An important factor to achieve that goal is to minimize damage to the vessel walls. Sutures inevitably induce vascular wall damage, which influences the healing of the anastomosis. Over time, several a

  12. 21 CFR 878.4930 - Suture retention device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... button, or a suture bolster, intended to aid wound healing by distributing suture tension over a larger...

  13. Subcuticular absorbable suture with subcutaneous drainage system prevents incisional SSI after hepatectomy for hepatocellular carcinoma.

    Science.gov (United States)

    Tsujita, Eiji; Yamashita, Yo-Ichi; Takeishi, Kazuki; Matsuyama, Ayumi; Tsutsui, Shin-Ichi; Matsuda, Hiroyuki; Taketomi, Akinobu; Shirabe, Ken; Ishida, Teruyoshi; Maehara, Yoshihiko

    2012-07-01

    The effectiveness of subcuticular absorbable suture with subcutaneous drainage to decrease the risk of postoperative incisional surgical site infection (SSI) in hepatocellular carcinoma (HCC) patients was evaluated. A total of 149 patients with HCC who underwent hepatectomy (Hx) were retrospectively investigated. Patients were divided into two groups: the patients with subcuticular suture combined with subcutaneous drainage (the drainage group; 61 patients) and the patients with nylon suture without subcutaneous drainage (the nylon group; 88 patients). After the operations, the complication rate of postoperative incisional SSI was analyzed and compared between the two groups. In the drainage group the rate of incisional SSI was significantly lower compared to the nylon group: 14-3 % (p = 0.033), respectively. Patients with incisional SSI needed significantly longer postoperative hospital care than the patients without incisional SSI: 28 versus 15 days (p SSI (odds ratio; 0.15; p = 0.034). We have demonstrated that the subcuticular suture with subcutaneous drainage is effective in preventing incisional SSI in patients undergoing Hx for HCC.

  14. Indirect reduction of posterior wall fragment using a suture anchor in acetabular posterior wall fracture with posterior labral root tear.

    Science.gov (United States)

    Yoo, Je-Hyun; Chang, Jun-Dong; Lee, Ho-Won

    2015-02-01

    Posterior wall fractures, which are the most common type of acetabulum fracture, are frequently accompanied with an avulsion tear of the posterior labral root as well as hip dislocation due to the injury mechanism. In the treatment of these fractures with an avulsed posterior labral root attached to posterior wall fragment, the use of a suture anchor can induce indirect reduction of a posterior wall fragment as well as direct repair of a labral root tear simultaneously. We describe the simple and efficient technique using a suture anchor in posterior wall acetabular fractures and surgical outcomes of two cases treated with this technique.

  15. Decomposition and analysis of laparoscopic suturing task using tool-motion analysis (TMA): improving the objective assessment.

    Science.gov (United States)

    Pagador, J B; Sánchez-Margallo, F M; Sánchez-Peralta, L F; Sánchez-Margallo, J A; Moyano-Cuevas, J L; Enciso-Sanz, S; Usón-Gargallo, J; Moreno, J

    2012-03-01

    The laparoscopic suturing task is a complex procedure that requires objective assessment of surgical skills. Analysis of laparoscopic suturing task components was performed to improve current objective assessment tools. Twelve subjects participated in this study as three groups of four surgeons (novices, intermediates and experts). A box-trainer and organic tissue were used to perform the experiment while tool movements were recorded with the augmented reality haptic system. All subjects were right-handed and developed a surgeon's knot. The laparoscopic suturing procedure was decomposed into four subtasks. Different objective metrics were applied during tool-motion analysis (TMA). Statistical analysis was performed, and results from three groups were compared using the Jonckheere-Terpstra test, considering significant differences when P ≤ 0.05. Several first, second and fourth subtask metrics had significant differences between the three groups. Subtasks 1 and 2 had more significant differences in metrics than subtask 4. Almost all metrics showed superior task executions accomplished by experts (lower time, total path length and number of movements) compared with intermediates and novices. The most important subtasks during suture learning process are needle puncture and first knot. The TMA could be a useful objective assessment tool to discriminate surgical experience and could be used in the future to measure and certify surgical proficiency.

  16. Performance of fast-absorbable suture and histo-glue in closing incisions in Brown trout

    DEFF Research Database (Denmark)

    Jepsen, Niels; Larsen, Martin Hage; Aarestrup, Kim

    2017-01-01

    , growth, tag expulsion rate and incision healing was compared among three groups of dummy transmitter-tagged wild brown trout Salmo trutta where incisions were closed with two types of suture material (absorbable vs. fast absorbable) and Histo-glue. The tagged fish were kept in semi-natural ponds for 20...

  17. 可吸收胶原蛋白线与丝线编织非吸收线在口腔种植中的应用%Absorbable collagen suture and non-absorbable silk suture in oral implantation

    Institute of Scientific and Technical Information of China (English)

    徐海洋; 徐昊; 张丽; 曲晓欣; 赵保东

    2014-01-01

    背景:胶原蛋白线由动物的胶原蛋白制备而成,由于其具备可降解、无排异、易于制备、使用方便等优点,现在已开始大量使用于临床。  目的:比较胶原蛋白线与丝线编织线对口腔种植手术切口愈合的影响。  方法:100例种植手术患者随机等分为可吸收胶原蛋白线组和丝线编织非吸收性缝线组,分别使用2-0带圆针可吸收胶原蛋白缝合线与4-0带圆针丝线编织非吸收性缝线对伤口进行间断无张力缝合。植入后3,5,7 d观察缝线及伤口愈合情况,植入后第7天拆线,植入后14 d复诊。  结果与结论:可吸收胶原蛋白线组患者切口甲级愈合率明显多于丝线编织非吸收性缝线组(P OBJECTIVE:To evaluate the effects of col agen suture and silk suture in wound healing after oral implant surgery. METHODS:100 patients undergoing oral implantation were randomly assigned into col agen suture group and silk suture group. A 2-0 circular needle with absorbable col agen sutures and a 4-0 circular needle with non-absorbable silk sutures were employed for tension-free suture in the two groups. After 3, 5, 7 days of oral implantation, suture threads and wound healing were observed. The suture was removed at 14 days, and patients were reviewed at 14 days. RESULTS AND CONCLUSION:The wound healing was better in the col agen suture group than the silk suture group at grade I (P<0.05). At 7 days postoperatively, the suture thread was mostly absorbed in the col agen group but not in the silk suture group. In addition, material alba was invisible in the col agen suture group but clear in the silk suture group. These results indicate that the col agen suture is more proper for tension-free suture than the silk suture, which is better matched to the healing time and keeps a better oral environment.

  18. Surgical Team Stability and Risk of Sharps-Related Blood and Body Fluid Exposures During Surgical Procedures.

    Science.gov (United States)

    Myers, Douglas J; Lipscomb, Hester J; Epling, Carol; Hunt, Debra; Richardson, William; Smith-Lovin, Lynn; Dement, John M

    2016-05-01

    To explore whether surgical teams with greater stability among their members (ie, members have worked together more in the past) experience lower rates of sharps-related percutaneous blood and body fluid exposures (BBFE) during surgical procedures. A 10-year retrospective cohort study. A single large academic teaching hospital. Surgical teams participating in surgical procedures (n=333,073) performed during 2001-2010 and 2,113 reported percutaneous BBFE were analyzed. A social network measure (referred to as the team stability index) was used to quantify the extent to which surgical team members worked together in the previous 6 months. Poisson regression was used to examine the effect of team stability on the risk of BBFE while controlling for procedure characteristics and accounting for procedure duration. Separate regression models were generated for percutaneous BBFE involving suture needles and those involving other surgical devices. RESULTS The team stability index was associated with the risk of percutaneous BBFE (adjusted rate ratio, 0.93 [95% CI, 0.88-0.97]). However, the association was stronger for percutaneous BBFE involving devices other than suture needles (adjusted rate ratio, 0.92 [95% CI, 0.85-0.99]) than for exposures involving suture needles (0.96 [0.88-1.04]). Greater team stability may reduce the risk of percutaneous BBFE during surgical procedures, particularly for exposures involving devices other than suture needles. Additional research should be conducted on the basis of primary data gathered specifically to measure qualities of relationships among surgical team personnel.

  19. Biomechanical Comparison of Parallel and Crossed Suture Repair for Longitudinal Meniscus Tears

    Science.gov (United States)

    Milchteim, Charles; Branch, Eric A.; Maughon, Ty; Hughey, Jay; Anz, Adam W.

    2016-01-01

    Background: Longitudinal meniscus tears are commonly encountered in clinical practice. Meniscus repair devices have been previously tested and presented; however, prior studies have not evaluated repair construct designs head to head. This study compared a new-generation meniscus repair device, SpeedCinch, with a similar established device, Fast-Fix 360, and a parallel repair construct to a crossed construct. Both devices utilize self-adjusting No. 2-0 ultra–high molecular weight polyethylene (UHMWPE) and 2 polyether ether ketone (PEEK) anchors. Hypothesis: Crossed suture repair constructs have higher failure loads and stiffness compared with simple parallel constructs. The newer repair device would exhibit similar performance to an established device. Study Design: Controlled laboratory study. Methods: Sutures were placed in an open fashion into the body and posterior horn regions of the medial and lateral menisci in 16 cadaveric knees. Evaluation of 2 repair devices and 2 repair constructs created 4 groups: 2 parallel vertical sutures created with the Fast-Fix 360 (2PFF), 2 crossed vertical sutures created with the Fast-Fix 360 (2XFF), 2 parallel vertical sutures created with the SpeedCinch (2PSC), and 2 crossed vertical sutures created with the SpeedCinch (2XSC). After open placement of the repair construct, each meniscus was explanted and tested to failure on a uniaxial material testing machine. All data were checked for normality of distribution, and 1-way analysis of variance by ranks was chosen to evaluate for statistical significance of maximum failure load and stiffness between groups. Statistical significance was defined as P < .05. Results: The mean maximum failure loads ± 95% CI (range) were 89.6 ± 16.3 N (125.7-47.8 N) (2PFF), 72.1 ± 11.7 N (103.4-47.6 N) (2XFF), 71.9 ± 15.5 N (109.4-41.3 N) (2PSC), and 79.5 ± 25.4 N (119.1-30.9 N) (2XSC). Interconstruct comparison revealed no statistical difference between all 4 constructs regarding maximum

  20. Operative treatment of acromioclavicular joint dislocation: a new technique with suture anchors.

    Science.gov (United States)

    Zhang, Jing-Wei; Li, Min; He, Xian-Feng; Yu, Yi-Hui; Zhu, Li-Mei

    2014-01-01

    To evaluate clinical outcome of suture anchors in strengthening both acromioclavicular and coracoclavicular ligaments in the surgical treatment of acromioclavicular joint dislocation. Twenty-eight patients with acute traumatic Rockwood III, IV and V dislocations of the acromioclavicular joint surgically treated at our institute between October 2010 and January 2012 were recruited.All patients underwent open reduction combined with suture anchors. Function was evaluated using the Constant- Murley shoulder score. Clinical and radiographic shoulder ratings were evaluated using Taft criteria at 3, 6 and 12 months. Two cases with fixation loosening were not included in final statistical analysis. Other patients obtained full joint reposition on immediate postoperative radiographs. Follow-up was performed with an average of 15.6 months (range, 12-19). After early range of motion exercises, 96.2% of the patients (25/26) could abduct and elevate their shoulders more than 90 degrees within postoperative 3 months. There was no infection. Average Constant-Murley score was 96.3 points (range, 94-100) and mean Taft shoulder rating was 10.7 points (range, 8-12) at 12 months. The suture anchor is a relatively simple technique and can avoid screw removal which is helpful in reconstructing both acromioclavicular and coracoclavicular ligaments in acute traumatic acromioclavicular joint dislocation.

  1. Abortion - surgical

    Science.gov (United States)

    Suction curettage; Surgical abortion; Elective abortion - surgical; Therapeutic abortion - surgical ... Surgical abortion involves dilating the opening to the uterus (cervix) and placing a small suction tube into the uterus. ...

  2. Comparação entre dois fios de sutura não absorvíveis na anastomose traqueal término-terminal em cães Comparison of two nonabsorbable suture materials in the end-to-end tracheal anastomosis in dogs

    Directory of Open Access Journals (Sweden)

    Sheila Canevese Rahal

    1995-01-01

    Full Text Available Doze cães sem raça definida, com idade variando entre 1 e 6 anos e peso de 6 a 20kg, foram submetidos a ressecção traqueal e anastomose término-terminal, na qual foram testados os fios poliéster trançado não capilar e náilon monofilamento. Seis animais, cada três com um mesmo tipo de fio de sutura, sofreram a excisão equivalente a três anéis traqueais. Com 15 dias foi executada uma nova intervenção onde se ressecou o equivalente a mais seis anéis, perfazendo um total de nove. Ao final de outros 15 dias foram sacrificados. Os outros seis animais, cada três com um mesmo tipo de fio, foram submetidos à excisão equivalente a três anéis traqueais e mantidos por 43 dias. As traquéias foram avaliadas por exames clínicos, radiográficos, macroscópicos e histopatológicos. O fio de náilon monofilamento apresentou menos reação tecidual do que o poliéster trançado não capilar, promoveu uma anastomose segura e com menor chance de formação de granuloma.Twelve mongrel dogs, with age between 1 and 6 years old and weight between 12 and 40 pounds, were submitted to tracheal resection and end-to-end anastomosis in which were tested braided polyester no capillary and monofilament nylon materiais. Six animais, every threeones with a same type of suture material, suffered the excision equivalent to three tracheal rings. A new intervention was performed with fifteen days, in which the equivalent of more six tracheal rings were removed, completing the total of nine. At the end of more fifteen days they were sacrificed. The other six animals, every three with a same type of suture material, were submitted to the excision equivalent to three tracheal rings and maintained for 43 days. The tracheal anastomosis were evaluated to clinic, radiographic, macroscopic and histopathologic studies. The monofilament nylon material exhibited less reaction than polyester and promoted a secure anastomosis with less risk of granuloma formation.

  3. Modified alar base cinch suture fixation at the bilateral lower border of the piriform rim after a maxillary Le Fort I osteotomy.

    Science.gov (United States)

    Yen, C Y; Kuo, C L; Liu, I H; Su, W C; Jiang, H R; Huang, I G; Liu, S Y; Lee, S Y

    2016-11-01

    Classic cinch suture narrowing of the nasal alar base by medially suturing the bilateral nasolabial soft tissue with one long suture has a limited effect. The modified cinch method described in the present study anchors non-absorbable sutures to the bilateral lower border of the piriform rim and provides optimal direction, position, and stability. The sutures can be shortened and the strength kept stable while the surgical wounds heal. Separate bilateral sutures can also reduce interference and distortion from nasotracheal intubation and make the nasolabial profile more symmetrical. Seventeen consecutive cases of maxillary Le Fort I osteotomy were analyzed. The nasal and alar base width changes were 0.4±1.2mm and 0.1±1.1mm, respectively, and the widening rate was only 1.1%. Compared with the results of other studies, postoperative nasal flaring was well controlled using the modified cinch suture anchored to the bilateral lower border of the piriform rim described in this study.

  4. Ten-year follow up after laparoscopic suture rectopexy for full-thickness rectal prolapse.

    Science.gov (United States)

    Foppa, C; Martinek, L; Arnaud, J P; Bergamaschi, R

    2014-10-01

    Studies have shown that recurrence rates of full-thickness rectal prolapse (FTRP) 5 years after surgery can quadruple at 10 years. This study aimed to evaluate the impact of laparoscopic suture rectopexy for FTRP on recurrence rates and functional outcome at a median follow up of 10 years. Prospectively collected data for patients who underwent laparoscopic suture rectopexy for FTRP between 1993 and 2006 were analysed. Laparoscopic rectopexy consisted of circumferential mobilization of the rectum down to the levator followed by suture suspension to promontory. Patients with preexisting constipation or who were unfit for general anaesthesia were not included. Incontinence, quality of life and constipation were assessed by validated scores. Recurrence-free curves were generated using the Kaplan-Meier method. One hundred and seventy-nine patients with a median age of 62 (15-93) years including 174 women and five men underwent laparoscopic suture rectopexy. There was no mortality. The 30-day complication rate was 4% (partial transection of the left ureter, pneumonia, urinary tract infection, urinary retention, superficial surgical site infection). Data on 172 patients (96%) were available at follow up. There were 10 recurrences of FTRP at 5-year follow up giving a crude recurrence rate of 6%. The actuarial 10-year recurrence rate was 20% (95% CI, 10.8-20.1). Follow-up continence (P < 0.0001) and quality of life were better than preoperatively: lifestyle (P < 0.001), coping (P < 0.001), self-perception (P < 0.005), embarrassment (P < 0.06). Constipation was unchanged. Laparoscopic suture rectopexy led to few complications, a recurrence rate of 20%, improved continence and quality of life with no worsening of constipation at 10 years. Colorectal Disease © 2014 The Association of Coloproctology of Great Britain and Ireland.

  5. Skin tension related to tension reduction sutures.

    Science.gov (United States)

    Hwang, Kun; Kim, Han Joon; Kim, Kyung Yong; Han, Seung Ho; Hwang, Se Jin

    2015-01-01

    The aim of this study was to compare the skin tension of several fascial/subcutaneous tensile reduction sutures. Six upper limbs and 8 lower limbs of 4 fresh cadavers were used. At the deltoid area (10 cm below the palpable acromion) and lateral thigh (midpoint from the palpable greater trochanter to the lateral border of the patella), and within a 3 × 6-cm fusiform area of skin, subcutaneous tissue defects were created. At the midpoint of the defect, a no. 5 silk suture was passed through the dermis at a 5-mm margin of the defect, and the defect was approximated. The initial tension to approximate the margins was measured using a tensiometer.The tension needed to approximate skin without any tension reduction suture (S) was 6.5 ± 4.6 N (Newton). The tensions needed to approximate superficial fascia (SF) and deep fascia (DF) were 7.8 ± 3.4 N and 10.3 ± 5.1 N, respectively. The tension needed to approximate the skin after approximating the SF was 4.1 ± 3.4 N. The tension needed to approximate the skin after approximating the DF was 4.9 ± 4.0 N. The tension reduction effect of approximating the SF was 38.8 ± 16.4% (2.4 ± 1.5 N, P = 0.000 [ANOVA, Scheffé]). The tension reduction effect of approximating the DF was 25.2% ± 21.9% (1.5 ± 1.4 N, P = 0.001 [ANOVA, Scheffé]). The reason for this is thought to be that the SF is located closely to the skin unlike the DF. The results of this study might be a basis for tension reduction sutures.

  6. Ultrasound biomicroscopy confirmation of corneal overriding due to improper suturing of full-thickness corneal laceration

    Directory of Open Access Journals (Sweden)

    Murat Kucukevcilioglu

    2014-12-01

    Full Text Available We herein present a case with corneal overriding due to improper suturing of a full-thickness corneal laceration. There was a 2.5-mm difference between horizontal and vertical white-to-white measurements in the cornea. However, slit lamp examination failed to demonstrate the exact architecture of the laceration. Ultrasound biomicroscopy defined the wound edges thoroughly and confirmed the presence of corneal overriding. Six weeks after suture enhancement, the abnormal oval appearance of the cornea was absent and correct apposition of the corneal edges was seen on ultrasound biomicroscopy. Ultrasound biomicroscopy can be used in preoperative surgical planning of cases with complicated corneal lacerations. It can be used to adjust and enhance wound architecture in eyes with penetrating injury.

  7. Mini-plate fixation versus suture suspensory fixation in cervical laminoplasty

    Science.gov (United States)

    Liu, Feng-Yu; Ma, Lei; Huo, Li-Shuang; Cao, Yan-Xiang; Yang, Da-Long; Wang, Hui; Yang, Si-Dong; Ding, Wen-Yuan

    2017-01-01

    Abstract Background: Both the mini-plate fixation and suture suspensory fixation techniques are extensively applied in cervical laminoplasty, but which technique is superior has not been ascertained. The purpose of this meta-analysis is to compare the results between mini-plate fixation and suture suspensory fixation in cervical laminoplasty for the patients with multilevel cervical compressive myelopathy. Methods: PubMed, Embase, the Cochrane library, CNKI, and WANFANG were searched for studies that compared mini-plate fixation and suture suspensory fixation in cervical laminoplasty up to November 1, 2016. We calculated odds ratio (OR) with 95% confidence interval (CI) for dichotomous outcomes and mean difference (MD) with 95% CI for continuous outcomes. Review Manager 5.3 was used for the statistical analyses. Results: A total of 25 studies, involving 1603 participants, were included in this review. The results of this meta-analysis indicated that there were statistically significant differences in postoperative Japanese Orthopedic Association (JOA) scores (MD = 0.67, 95% CI: 0.34–0.99, P statistically significant difference in C5 palsy (OR = 0.82, 95% CI: 0.37–1.84, P = 0.63). Conclusions: As compared with suture suspensory fixation, mini-plate fixation in cervical laminoplasty appears to achieve better clinical and radiographic outcomes with fewer surgical complications. However, mini-plate fixation is associated with bigger surgical trauma. This conclusion should be interpreted cautiously and more high-quality, randomized controlled trials are needed in the future. PMID:28151906

  8. No-mesh inguinal hernia repair with continuous absorbable sutures: A dream or reality? (a study of 229 patients

    Directory of Open Access Journals (Sweden)

    Desarda Mohan

    2008-01-01

    Full Text Available Background/Aim: The author has published results from two series based on his new technique of inguinal hernia repair. Interrupted sutures with a nonabsorbable material were used for repairs in both theses series. The author now describes the results of repairs done with continuous absorbable sutures. Materials and Methods: This is a prospective study of 229 patients having 256 hernias operated from December 2003 to December 2006. An undetached strip of the external oblique aponeurosis was sutured between the inguinal ligament and the muscle arch to form the new posterior wall. Continuous sutures were taken with absorbable suture material (Monofilament Polydioxanone Violet. Data of hospital stay, complications, ambulation, recurrences, and pain were recorded. Follow-up was done until June 2007. Results: A total of 224 (97.8% patients were ambulatory within 6-8 h (mean: 6.42 h and they attained free ambulation within 18-24 h (mean: 19.26 h. A total of 222 (96.4% patients returned to work within 6-14 days (mean: 8.62 days and 209 (91.26% patients had one-night stays in the hospital. A total of 216 (94.3% patients had mild pain for 2 days. There were four minor complications, but no recurrence or incidence of chronic groin pain. Patients were followed up for a mean period of 24.28 months (range: 6-42 months. Conclusions: The results of this study correlate well with the author′s previous publications. Continuous suturing saves operative time and one packet of suture material. The dream of every surgeon to give recurrence-free inguinal hernia repair without leaving any foreign body inside the patient may well become a reality in future.

  9. The use of imbricated sutures in radioactive plaque brachytherapy surgery

    Directory of Open Access Journals (Sweden)

    Kaan Gündüz

    2010-03-01

    Full Text Available Kaan Gündüz1, Jose S Pulido1, Peter D Yeakel2, Michael King3, Kelly L Classic1, Keith M Furutani21Department of Ophthalmology, 2Department of Radiation Oncology, 3Section of Media Support Services, Mayo Clinic, Rochester, MN, USAAbstract: This paper describes a new technique to suture the radioactive plaque to sclera. The radioactive plaque is conventionally sutured to the sclera using 5/0 nylon sutures. The imbricated suture technique involves using a 1/0 silk or 2/0 mersilene suture imbricated with the 5/0 nylon suture when the nylon suture is tied and cut. The imbricated suture technique allows easy identification of the plaque at removal and provides a surface that separates the 5/0 nylon from the surface of the eyelet platform, making suture cutting easier and safer. The radiation exposure times ranged from 9.1 minutes to 14 minutes (mean: 10.8 minutes during plaque insertion and from 2.8 to 3.3 minutes (mean: 3.0 minutes during plaque removal with the imbricated suture technique. This technique may decrease radiation exposure time and may prevent inadvertent scleral damage.Keywords: plaque radiotherapy, Iodine-125, Ruthenium-106, Collaborative Ocular Melanoma Study, choroidal melanoma, ciliary body melanoma, retinoblastoma, plaque placement, plaque removal, radiation exposure

  10. Cranial suture biology of the Aleutian Island inhabitants.

    Science.gov (United States)

    Cray, James; Mooney, Mark P; Siegel, Michael I

    2011-04-01

    Research on cranial suture biology suggests there is biological and taxonomic information to be garnered from the heritable pattern of suture synostosis. Suture synostosis along with brain growth patterns, diet, and biomechanical forces influence phenotypic variability in cranial vault morphology. This study was designed to determine the pattern of ectocranial suture synostosis in skeletal populations from the Aleutian Islands. We address the hypothesis that ectocranial suture synostosis pattern will differ according to cranial vault shape. Ales Hrdlicka identified two phenotypes in remains excavated from the Aleutian Island. The Paleo-Aleutians, exhibiting a dolichocranic phenotype with little prognathism linked to artifacts distinguished from later inhabitants, Aleutians, who exhibited a brachycranic phenotype with a greater amount of prognathism. A total of 212 crania representing Paleo-Aleuts and Aleutian as defined by Hrdlicka were investigated for suture synostosis pattern following standard methodologies. Comparisons were performed using Guttmann analyses. Results revealed similar suture fusion patterns for the Paleo-Aleut and Aleutian, a strong anterior to posterior pattern of suture fusion for the lateral-anterior suture sites, and a pattern of early termination at the sagittal suture sites for the vault. These patterns were found to differ from that reported in the literature. Because these two populations with distinct cranial shapes exhibit similar patterns of suture synostosis it appears pattern is independent of cranial shape in these populations of Homo sapiens. These findings suggest that suture fusion patterns may be population dependent and that a standardized methodology, using suture fusion to determine age-at-death, may not be applicable to all populations.

  11. USE OF PLASTIC MATERIAL AND TRIPLE SCAN IN THE PREPARATION OF SURGICAL GUIDES FOR THE DENTAL IMPLANT TREATMENT-CASE REPORT

    Directory of Open Access Journals (Sweden)

    Rosen Borisov

    2016-09-01

    Full Text Available The use of surgical guides in implant treatment increases the accuracy of the dental implant positioning compared with manual methods. Regardless of how they are made, deviations of implants from their intended position are established in all kinds of surgical guides. This article considers the use of plastic material and new scanning technique for the production of CAD/CAM surgical guides that aim to overcome the deficiencies of the currently applied technologies in the production of surgical guides. Materials and methods: The study shows the techniques used to overcome degraded by metal artifacts CBCT images in implant treatment of patients with partial edentulism, and located medially to the defect metal-ceramic crowns. When planning implant treatment, a triple scan method has been implied. At the beginning, CBCT scan of the patient with a silicone impression material is made in the zone of interest. Secondly, CBCT scan only of the silicon impression is made, and thirdly - intraoral scanning of the patient with an intraoral scanner. Virtual analogues have been created of images from the three scans and have been repositioned one over another; as thereby an intraoral image have been accurately positioned over the CBCT image of the patient. Virtual planning of the implant positioning has been performed, and a model of surgical guide has been made for their placement. The guide has been printed with an SLA 3D printer technology of photopolymer with dualistic characteristics-rigid in the working part and plastic in the fixing part. Through it, implants have been placed to the treatment planning. Postoperative CBCT has been done on the patient to measure the implant deviation to their position in the treatment planning. Results: Axes angular deviation of the planned and placed implants has not been established. Average linear displacement of 240 μ (+/- 40 μ has been found. Conclusions: Using the triple scan method is possible to overcome the

  12. [Cause and prevention of surgical site infection and hypertrophic scars].

    Science.gov (United States)

    Ogawa, Rei

    2012-03-01

    Surgical site infection (SSI) occurs at the site of surgery within 1 month of an operation or within 1 year of an operation if a foreign body is implanted as part of the surgery. Most SSIs (about 70%) are superficial infections involving the skin and subcutaneous tissues only. The remaining infections are more serious and can involve tissues under the skin, organs, or implanted material. Hypertrophic scars( HSs) occur frequently on particular sites, including the anterior chest wall. The anterior chest wall is frequently subjected to skin stretching caused by the natural daily movements of the body. Most cases of SSIs and HSs can be prevented by (1) suture technique modification to prevent high stretching tension and ischemia, and (2) appropriate wound care after surgery. It would be useful to avoid subjecting wounded skin to sustained mechanical force, thereby permitting the wound to rest and heal normally.

  13. Subcutaneous Achilles tendon rupture: A comparison between open technique and mini-invasive tenorrhaphy with Achillon(®) suture system.

    Science.gov (United States)

    Daghino, W; Enrietti, E; Sprio, A E; di Prun, N Barbasetti; Berta, G N; Massè, A

    2016-11-01

    Surgical management of Achilles tendon rupture is still controversial: open techniques have a higher rate of soft tissue complications but a lower incidence of re-rupture than percutaneous tenorrhaphies. The aim of our retrospective study was to analyze and compare clinical and functional results in patients treated with either the conventional open or minimally invasive suture treatment with the Achillon(®) system. A retrospective review of 140 patients was performed; 72 were treated with open tenorrhaphy, 68 with the minimally invasive Achillon(®) suture system. With a comparable re-rupture rate, there was a statistically significant reduction in surgical time, incidence of minor complications, time required to return to sport activities and return to work in the minimally invasive group. Achillon(®) mini-invasive suture system is a reliable tool for the Achilles tendon ruptures, able to reduce the incidence of soft tissues complications if compared to the classic open tenorrhaphy, while maintaining strength of the suture and leading to superimposed functional outcomes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. LigaSure versus Conventional Suture Ligature for Vaginal Hysterectomy: a Randomized Controlled Trial

    Directory of Open Access Journals (Sweden)

    Mohamed Abd Elzaher, a, b, Ashraf Moawad, a, c and Hanaa Abu-Ria

    2011-07-01

    Full Text Available Introduction: Vaginal hysterectomy is considered to be the method of choice for removal of the uterus. Of particular concern for the vaginal surgeon is the ability to access, visualize, and legate structures while maintaining adequate hemostasis. Surgical hemostasis can be secured by a variety of methods, including mechanical means (sutures or vessel coagulation (diathermy. Electro-surgical vessel sealing (LigaSure is a new hemostatic system based on the combination of pressure and bipolar electrical energy and is able to seal vessels up to 7 mm in diameter. Objective: To assess the safety and efficacy of using the LigaSure vessel sealing system for securing the pedicles during vaginal hysterectomy in comparison with the conventional method of securing the pedicles by suture ligation. Design: Prospective randomized controlled trial. Setting: Obstetrics and Gynecology departments (Al-Kharj University Hospital- KSA, Enjab Hospital - UAE and Gulf Medical College and Research Centre- UAE. Methods: 80 patients undergoing vaginal hysterectomy for benign conditions were randomized to either LigaSure group (n=40 or Suture group (n=40. Main outcome measures: The primary outcome measures were the operative time and blood loss while the secondary outcome measures were the hospital stay and intra- and post-operative complications. Results: Patients in the LigaSure group had a significantly reduced operating time (37.1 ± 8.9 min vs. 63.8 ± 10.9 min; P < 0.001, operative blood loss (125.5 ± 33.2 mL vs. 264.6 ± 70.4 mL; P < 0.001, requirement of surgical sutures(1.2 ± 0.4 units vs. 8.2 ± 0.4 units; p < 0.001, pain status (2.0 ± 0.6 vs. 3.7 ± 0.7; P < 0.001, and hospital stay (30.3 ± 2.5 h vs. 45.7 ±10.5 h; P < 0.001 compared to the control group. The overall complication rate in the study was 10 % (8/80, and did not differ between patients of the LigaSure and control group. Conclusion: The use of LigaSure device can reduce operative time. It allows

  15. Halstedian technique revisited. Innovations in teaching surgical skills.

    Science.gov (United States)

    Barnes, R W; Lang, N P; Whiteside, M F

    1989-07-01

    This paper reviews the laboratory models used to teach fundamental surgical skills in our general surgery residency. The laboratory modules allow supervision and self-instruction, practice, and videotape monitoring of the following techniques: skin incision, suturing, knot tying, hemostasis, vascular anastomosis, and intestinal anastomosis. Pigs' feet simulate human skin for exercises in skin incision, lesion excision, suturing, and basic plastic surgical techniques. Latex tubing and penrose drains allow experience in suturing, knot tying, and hemostasis. Polytetrafluoroethylene vascular prostheses permit quantification of the precision of needle passage and suturing by measurement of leakage of water through a vascular anastomosis. Reconstituted, lyophilized, irradiated bovine arteries and ileum provide models of biologic tissue for creating handsewn vascular anastomoses and sutured or stapled gastrointestinal anastomoses. A headlamp videocamera allows unobstructive recording of the resident's technical performance and provides subsequent visual feedback for self-improvement when compared to reference instructional videotapes. We feel that these innovations may enhance surgical dexterity of residents without the need for animal sacrifice. Our goal is to foreshorten the learning curve for basic surgical skills and improve performance in the clinical operating room.

  16. Bidirectional lift of the anterior midcheek with Gore-Tex cable sutures.

    Science.gov (United States)

    Sasaki, Gordon H; Oberg, Kerby C; Kim, E Yoonah

    2003-01-01

    The reader is presumed to have a broad understanding of the anatomy of the anterior midface. After reading this article, the participant should be able to: Physicians may earn 1 hour of Category 1 CME credit by successfully completing the examination on the basis of material covered in this article. The examination begins on page 257. We have previously described a technique of anterior midface soft tissue repositioning using 2 cable sutures directed only in a superolateral direction. This technique achieves a more normal distribution of subcutaneous fat laterally over the malar bag prominence but does little to overcome central and medial hollowness in the palpebromalar and tear-trough areas. We describe an alteration of our original technique that introduces a vertical lift of the anterior midface soft tissue utilizing Gore-Tex, (W.L. Gore & Associates, Flagstaff, AZ) cable sutures while elevating the preperiosteal soft tissue. We used a transconjunctival approach to expose the postseptal fat, orbital rim, and arcus marginalis. Subperiosteal dissection over the orbital rim was performed to prepare a pocket for the malar fat pads. Using 6.5-cm Keith needles, we placed a braided suture medially, lateral to the location of the infraorbital nerve and foramen, and maneuvered it through the soft tissue until all signs of dimpling at the nasolabial line or upward distortion of the upper lip were removed. A Gore-Tex graft was introduced and seated in a cupped configuration that anchored the caudal fat pad at the nasolabial line. The medial fat pad and vascular pedicle were transposed over the orbital rim into the predissected pocket; the central fat pad was also fashioned into a pedicle and moved into its pocket. The Gore-Tex sutures were tightened, elevating the supraperiosteal soft tissue vertically. A second set of Gore-Tex sutures elevated the anterior midface soft tissue toward the deep temporal fascia. Between 1999 and 2002, 197 patients underwent bidirectional

  17. Assessing the performance characteristics and clinical forces in simulated shape memory bone staple surgical procedure: The significance of SMA material model.

    Science.gov (United States)

    Saleeb, A F; Dhakal, B; Owusu-Danquah, J S

    2015-07-01

    This work is focused on the detailed computer simulation of the key stages involved in a shape memory alloy (SMA) osteosynthesis bone stapling procedure. To this end, a recently developed three-dimensional constitutive SMA material model was characterized from test data of three simple uniaxial-isothermal-tension experiments for powder metallurgically processed nickel-rich NiTi (PM/NiTi-P) material. The calibrated model was subsequently used under the complex, thermomechanical loading conditions involved in the surgical procedure using the body-temperature-activated PM/NiTi-P bone staple. Our aim here is to assess the immediate and post-surgical performance characteristics of the stapling operation using the material model. From this study: (1) it was found that adequate compressive forces were developed by the PM/NiTi-P bone staple, with the tendency of this force to even increase under sustained thermal loading due to the intrinsic "inverse relaxation phenomena" in the SMA material, (2) the simulation results correlated well with those from experimental measurements, (3) the body-temperature-activated PM/NiTi-P staple was proved to be clinically viable, providing a stable clamping force needed for speedy coaptation of the fractured bones, and (4) these realistic assessments crucially depend on the use of suitable and comprehensive SMA material models. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. A study of sutural bones in Gujarati (Indian) crania.

    Science.gov (United States)

    Pal, G P; Bhagwat, S S; Routal, R V

    1986-03-01

    370 adult crania were examined to find the incidence of sutural bones in Gujarati (Indian) crania and to compare it with other populations to establish the distance between them. The mean measure of difference between Indian and other populations was statistically significant. Comparison of cranial capacity in skulls with and without sutural bones showed no significant difference, and this is interpreted as indicating that sutural bones are not formed secondary to stress.

  19. Safety Pin Suture for Management of Atonic Postpartum Hemorrhage

    OpenAIRE

    Zaitoun, Mostafa M.; Mostfa, Ali Abdelhamed M.

    2012-01-01

    Objective. To assess the efficacy of a new suture technique in controlling severe resistant uterine atonic postpartum hemorrhage. Patients and Methods. This is a retrospective observational study that included thirteen women with uterine atony and postpartum bleeding that did not react to usual medical management. All these women underwent compressing vertical suture technique in which the anterior and posterior walls of the uterus were attached so as to compress the uterus. The suture is tra...

  20. Bone suture and lateral sinus lift surgery

    Directory of Open Access Journals (Sweden)

    Amin Rahpeyma

    2015-01-01

    Full Text Available Bone suture in lateral sinus lift has four indications. Three of them depend on creating a hole in the lateral maxillary sinus wall above the antrostomy window for securing the elevated medial maxillary sinus membrane to manage perforated Schneiderian membrane. Covering the buccal antrostomy window with the buccal fat pad (BFP for better nourishment of the inserted graft and as an alternative for bone tags in fixation of collagen membrane has been reported previously. A new indication for firmly anchoring the BFP to the medial maxillary sinus wall as the last resort for the management of perforated Schneiderian membrane is explained in this article.

  1. Surgical Assisting

    Science.gov (United States)

    ... Insert and remove Foley urinary bladder catheter Place pneumatic tourniquet Confirm procedure with surgeon Drape patient within ... Technology and Surgical Assisting (NBSTSA) offers the CertifiedSurgical First Assistant (CSFA) credential, and the National Surgical Assistant ...

  2. Teflon-buttressed sutures plus pericardium patch repair left ventricular rupture caused by radiofrequency catheter ablation: A case report.

    Science.gov (United States)

    Cao, Hao; Zhang, Qi; He, Yanzhong; Feng, Xiaodong; Liu, Zhongmin

    2016-09-01

    Cardiac rupture often occurs after myocardial infarction or chest trauma with a high mortality rate. However, left ventricular rupture caused by radiofrequency catheter ablation (RFCA) is extremely rare. We describe a case of a 61-year-old male who survived from left ventricular rupture caused by a RFCA procedure for frequent ventricular premature contractions. Surgical exploration with cardiopulmonary bypass (CPB) was performed when the signs of cardiac tamponade developed 7 hours after the ablation surgery. Teflon-buttressed sutures of the tear in the left ventricular posterolateral wall and pericardium patch applied to the contusion region on the wall repaired the rupture safely and effectively. Timely surgical intervention under CPB facilitated the survival of the patient. Teflon-buttressed sutures plus pericardium patch achieved the successful repair of the rupture.

  3. Surgical Complications of Cochlear Implantation

    Directory of Open Access Journals (Sweden)

    Basir Hashemi

    2010-03-01

    Full Text Available Cochlear implantation is a method used for the treatment ofpatients with profound hearing loss. This procedure may theaccompanied by some major or minor complications. Weevaluated the surgical complications of cochlear implantationin Fars province (south of Iran. A total of 150 patients withcochlear implantation were enrolled in the present study. Mostof the patients were pre-lingual children and most of our deviceswere nucleus prosthesis. We had three device failuresand four major complications, including one misplaced electrode,one case of meningitis, one case of foreign body reactionto suture and one case with extensive hematoma. Thesecomplications were managed successfully by surgical interventionor re-implantation. Facial nerve damage or woundbreakdown was not seen. Minor complications including smallhematoma, edema, stitch infection and dizziness were found in15 cases, which were managed medically. In our center, therate of minor complications was comparable to other centersin the world. But the rate of major surgical complications waslower than other centers.

  4. A Wireless Sensor for Real-Time Monitoring of Tensile Force on Sutured Wound Sites.

    Science.gov (United States)

    DeRouin, Andrew; Pacella, Nina; Zhao, Chunfeng; An, Kai-Nan; Ong, Keat Ghee

    2016-08-01

    A new wireless sensor was designed, fabricated, and applied for in situ monitoring of tensile force at a wound site. The sensor was comprised of a thin strip of magnetoelastic material with its two ends connected to suture threads for securing the sensor across a wound repair site. Since the sensor was remotely interrogated by applying an ac magnetic field and capturing the resulting magnetic field, it did not require direct wire connections to an external device or internal battery for long-term use. Due to its magnetoelastic property, the application of a tensile force changed the magnetic permeability of the sensor, altering the amplitude of the measured magnetic field. This study presents two sensor designs: one for high and one for low-force ranges. A sensor was fabricated by directly adhering the magnetoelastic strip to the suture. This sensor showed good sensitivity at low force, but its response saturated at about 1.5 N. To monitor high tensile force, the magnetoelastic strip was attached to a metal strip for load sharing. The suture thread was attached to the both ends of the metal strip so only a fraction of the applied force was directed to the sensor, allowing it to exhibit good sensitivity even at 44.5 N. The sensor was applied to two ex vivo models: a sutured section of porcine skin and a whitetail deer Achilles tendon. The results demonstrate the potential for in vivo force monitoring at a wound repair site.

  5. Tensile strength of a weave tendon suture using tendons of different sizes.

    Science.gov (United States)

    Mazurek, Tomasz; Strankowski, Michał; Ceynowa, Marcin; Rocławski, Marek

    2011-05-01

    This study compared the maximum load, stress, elongation at failure and the mode of failure of three kinds of tendons most frequently used for tendon grafting and tendon transfers, using the Pulvertaft weave suture. Sixty tendons were used from fresh human cadaver upper and lower extremities. The performed repairs included: 9 specimens of flexor digitorum superficialis or profundus tendon with flexor digitorum superficialis or profundus tendon (thick-thick suture), 10 specimens of flexor digitorum superficialis or profundus tendon with palmaris longus tendon (thick-medium thin suture), and 10 specimens of flexor digitorum superficialis or profundus tendon with plantaris tendon (thick-thin suture). Material testing machine was used to test repairs to failure. The mean maximum load at failure increased with the thickness of donor tendon. For the thick-thick specimen, the maximum load at failure was 125 newtons (N), for the thick-medium thin specimen it was 86,8N, and for the thick-thin it was 65,2N. These differences were all statistically significant. The active rehabilitation protocol is possible only with thick-thick connections used, the strength of the thick-medium thin connection is on the border of indications for the active rehabilitation protocol, and the thick-thin connection strength is sufficient only for the passive rehabilitation protocol. Copyright © 2010. Published by Elsevier Ltd.

  6. Role of suture anchors in management of fractures of inferior pole of patella

    Directory of Open Access Journals (Sweden)

    Anand Ashish

    2010-01-01

    Full Text Available Background: The traditional recommendation for displaced comminuted inferior pole fractures is excision of the comminuted pole followed by reattachment of the patellar tendon with transosseous suture. To the best of our knowledge there has been no previous published study mentioning the use of suture anchors for fracture inferior pole of patella. We present a retrospective analysis of five cases of patients doing well at final follow-up of two years. Materials and Methods: Five patients treated at our institute using suture anchors for repair of comminuted inferior pole fractures of patella between January 2007 to March 2007. (range 28 years-55 years. There were three males and two females. Results: The average follow-up was 25 months (range 24 months-26 months. The patients were evaluated for range of motion, strength, patellofemoral scores and any alteration of patellar height. The outcome of the procedure was assessed with use of the patellofemoral scoring system of Noyes et al, 5 as adapted by Saltzman et al. 6 The final patellofemoral score (maximum 100 points was 94.6 (range 93-96. Conclusion: We believe it is a novel extended indication of the use of suture anchors and should be in the armament of every trauma surgeon.

  7. [Inguinofemoral hernia: multicenter study of surgical techniques].

    Science.gov (United States)

    Porrero, José L; Sánchez-Cabezudo, Carlos; Bonachía, Oscar; López-Buenadicha, Adolfo; Sanjuánbenito, Alfonso; Hidalgo, Manuel

    2005-07-01

    The present study was performed by the Spanish Association of surgeons through its abdominal wall and sutures section. The aim was to determine the current situation of inguinofemoral hernias in Spain and was based on an anonymous multicenter study with the participation of various national hospitals. Fifty general surgery departments in distinct surgical centers throughout Spain responded to an anonymous survey in 2000. The survey gathered data on anesthetic features, surgical techniques and complications in the treatment of inguinofemoral hernias. Sixty-six percent of hospital centers had a specific abdominal wall unit and 24% performed laparoscopic hernia surgery. Prosthetic techniques (especially Lichtenstein) were the most frequently used in the treatment of primary inguinal hernia (72%) and recurrent hernia (100%). The most frequently used prosthetic material was polypropylene mesh (76%). Only 28% of the departments surveyed performed anatomic techniques in the repair of primary inguinal hernia (Shouldice and Bassini). The most frequent treatment for femoral hernia was the Lichtenstein "plug" (78%). Sixty-eight percent of the centers surveyed performed regional anesthesia, 18% used general anesthesia and only 14% used local anesthesia with sedation. Severe complications were found in 20% of departments. Clinical postoperative follow-up was performed in 96% of the centers and telephone follow-up was used in 4%. The recurrence rate was 1.2% for primary inguinal hernia, 2.7% for recurrent inguinal hernia and 0.3% for femoral hernia. In Spain the most commonly used surgical technique in the treatment of inguinal hernia is Lichtenstein hernioplasty under spinal anesthesia and with polypropylene prosthesis. The Lichtenstein plug is the most commonly used technique in the treatment of femoral hernia.

  8. The effectiveness of b-lynch sutures in management of atonic postpartum haemorrhage during caesarean section

    Directory of Open Access Journals (Sweden)

    Nidhi Kalkal

    2016-09-01

    Conclusions: This procedure proves to be a valuable addition for surgical treatment of atonic PPH and great advantage in young patients with restoration of future fertility with the added advantage of lesser time of application, lesser blood loss, lesser blood transfusion, lesser skill required. Thus, B-Lynch suturing can be adopted as a mid-step before resorting to uterine devascularisation or hysterectomy when medical line of management fails. [Int J Reprod Contracept Obstet Gynecol 2016; 5(9.000: 2915-2920

  9. Suture Granuloma Mimicking Renal Cell Carcinoma: Magnetic Resonance Imaging (MRI and Pathologic Correlation

    Directory of Open Access Journals (Sweden)

    İbrahim İlker Öz

    2014-11-01

    Full Text Available Solid renal masses are generally distinguished with contrast enhancement and intratumoral fatty foci by radiological examinations. The present of enhancement is most important criteria for diagnosis of malignant lesions. Generally, a contrast enhanced solid mass in kidney is accepted as a neoplasm. Foreign body granuloma is an extraordinary cause of enhanced solid renal mass. This case of a renal suture granuloma demonstrated peripheral enhanced exophytic renal mass mimic renal cell carcinoma, and underwent surgery. At the solid renal mass with different radiological features, biopsy is an option to determining the necessity of surgery as well as the surgical approach.

  10. Sutura arterial com técnicas contínua e de pontos separados, utilizando-se os fios polipropilene e polidioxanone: estudo experimental em coelhos Arterial suture with continuous and interrupted techniques, using polypropylene and polydioxanone threads: experimental study in rabbits

    Directory of Open Access Journals (Sweden)

    Nelson Leonardo Kerdahi Leite de Campos

    2003-10-01

    following itens were assessed: weight, arterial diameters and pulse, stenosis, thrombosis, tissue adherence at the suture line, aortography, suture material visibility, suture line healling visibility and microscopic study. RESULTS: a after 60 days, the suture line site had a significant growing in all groups; b interrupted technique result less suture line stenosis in surgical act and in euthanasia c the difference between groups showed in the microscopic study, was transitory, not pesisting after 60 days post surgery; CONCLUSION: Polydioxanone is better than polypropylene for suture in growing artery, not causing (or causing little restriction to the growing of the suture line, even though using continuous technique.

  11. Smart tissue anastomosis robot (STAR): a vision-guided robotics system for laparoscopic suturing.

    Science.gov (United States)

    Leonard, Simon; Wu, Kyle L; Kim, Yonjae; Krieger, Axel; Kim, Peter C W

    2014-04-01

    This paper introduces the smart tissue anastomosis robot (STAR). Currently, the STAR is a proof-of-concept for a vision-guided robotic system featuring an actuated laparoscopic suturing tool capable of executing running sutures from image-based commands. The STAR tool is designed around a commercially available laparoscopic suturing tool that is attached to a custom-made motor stage and the STAR supervisory control architecture that enables a surgeon to select and track incisions and the placement of stitches. The STAR supervisory-control interface provides two modes: A manual mode that enables a surgeon to specify the placement of each stitch and an automatic mode that automatically computes equally-spaced stitches based on an incision contour. Our experiments on planar phantoms demonstrate that the STAR in either mode is more accurate, up to four times more consistent and five times faster than surgeons using state-of-the-art robotic surgical system, four times faster than surgeons using manual Endo360(°)®, and nine times faster than surgeons using manual laparoscopic tools.

  12. Sulcus vocalis: excision, primary suture and medialization laryngoplasty: personal experience with 44 cases.

    Science.gov (United States)

    Yılmaz, Taner

    2012-11-01

    This is a prospective, cohort study to present personal experience on excision of sulcus, primary suture of defect and medialization laryngoplasty. An article about this subject is not present in medical literature. Forty-four patients with sulcus vocalis who were operated on by excision, primary suture of epithelial defect and medialization laryngoplasty were included. Pre- and postoperative evaluations included GRBAS, VHI-30, stroboscopy, aerodynamic and acoustic analysis. Grade, roughness and breathiness of GRBAS were significantly better postoperatively (p  0.05). All VHI-30 results decreased significantly after surgery (p  0.05). Maximum phonation time, mean airflow rate, mean efficiency and mean pressure of aerodynamic analysis improved significantly after surgery (p  0.05). All parameters, except F (0) and soft phonation index during acoustic analysis with /a/, and except F (0), voice turbulence index and soft phonation index during acoustic analysis with constant phrase improved significantly after surgery (p sulcus vocalis are not satisfactory enough, yet. Excision of sulcus, primary suture of epithelial defect and medialization laryngoplasty is one of the successful surgical options. Intact vocal ligament at the bottom of sulcus is a good prognostic sign for good postoperative voice result. Success appears to depend on how long, how wide and how deep sulcus is. Good patient selection may increase the percentage of happy patients.

  13. Arthroscopic Double-Row Suture Anchor Repair of Acute Posterior Bony Bankart Lesion.

    Science.gov (United States)

    Ly, Justin A; Coleman, Erin M; Kropf, Eric J

    2016-08-01

    The treatment of anterior shoulder instability is well described with various techniques, including arthroscopic double-row repair, an alternative to open stabilization procedures in high-risk groups. The surgical management of posterior instability in high-risk and athletic populations is a less-explored entity. We describe our technique for an all arthroscopic double-row suture anchor repair of a large posterior bony Bankart lesion. We prefer this technique over percutaneous cannulated screw fixation because the double-row suture technique allows for incorporation of capsular plication with bony fixation in an effort to better restore normal anatomy for capsulolabral complex. Double-row repair capsulolabral repair or fixation of the bony Bankart is performed via a suture-bridge technique. Medial row anchors are placed down the glenoid neck and shuttled around the bony fragment and labrum. The lateral-row anchor is placed at the rim of the native glenoid. This repair technique has been shown to increase the surface area for healing and more closely reconstruct the native anatomic capsulolabral complex footprint, improve force distribution, and potentially impart enhanced posterior stability to the glenohumeral joint.

  14. [Improvement of vaginal relaxation by vaginal narrowing technique with double suturing].

    Science.gov (United States)

    Liu, Sanhu; Cen, Ying; Liu, Quan

    2009-12-01

    To investigate the surgical procedures and outcomes of curing the mild and medium vaginal relaxation by double suturing vaginal muscularis. From May 2005 to November 2008, 8 patients (aged 30-45 years old) with mild and medium vaginal relaxation were treated. All the patients were married and had reproductive history of natural childbirth. The double semiring suture was performed in the region 4 cm and 0.5 cm away from the vaginal orifice, respectively, forming the first and the second semicircle to make vagina outside 1/3 segments and vagina muscles tighten. The time of operation was 20-30 minutes (average 25 minutes). There was no obvious bleeding and injury of the rectum and urethra during operation. All the incisions healed by first intention. The vagina accommodated 2 fingers without scar on its mucosa 1-2 months after operation. Eight patients were followed up for 6-24 months and the patients resumed their sexual life 4-8 weeks after operation with satisfied improvement. The technique of double suturing vaginal muscularis is easy and simple to perform with mild injury, fast postoperative recovery, and less postoperative complications. It is one of the effective methods to treat mild and medium vaginal relaxation.

  15. Early weightbearing using Achilles suture bridge technique for insertional Achilles tendinosis: a review of 43 patients.

    Science.gov (United States)

    Rigby, Ryan B; Cottom, James M; Vora, Anand

    2013-01-01

    Posterior heel pain caused by insertional Achilles tendinosis can necessitate surgical intervention when recalcitrant to conservative care. Surgical treatment can necessitate near complete detachment of the Achilles tendon to fully eradicate the offending pathologic features and, consequently, result in long periods of non-weightbearing. A suture bridge technique using bone anchors is available for reattachment of the Achilles tendon. This provides restoration of the Achilles footprint on the calcaneus, including not only contact, but also actual pressure between the tendon and bone. We performed a review of 43 patients who underwent surgical treatment of insertional Achilles tendinosis with reattachment of the Achilles tendon using the suture bridge technique. The mean age was 53 (range 29 to 87) years. The mean follow-up period was 24 (range 13 to 52) months. The mean postoperative American Orthopaedic Foot and Ankle Society score was 90 (range 65 to 100). The mean preoperative visual analog scale pain score was 6.8 (range 2 to 10) and the mean postoperative visual analog scale pain score was 1.3 (range 0 to 6). The mean interval to weightbearing was 10 (range 0 to 28) days. No postoperative ruptures occurred. Of the 43 patients, 42 (97.6%) successfully performed the single heel rise test at the final postoperative visit. Concomitant procedures were performed in 35 patients, including 33 (77%) requiring open gastrocnemius recession and 2 (5%) requiring flexor hallucis longus tendon transfer. A total of 42 patients (97.6%) returned to regular shoe gear, and 42 (97.6%) returned to their activities of daily living, including running for 20 athletic patients (100%). Complications included postoperative wound dehiscense requiring surgical debridement in 2 patients (5%) and soft tissue infection requiring antibiotics and surgical debridement in 1 (2%) patient. Our findings support using the Achilles tendon suture bridge for reattachment of the Achilles tendon in the

  16. Safety pin suture for management of atonic postpartum hemorrhage.

    Science.gov (United States)

    Mostfa, Ali Abdelhamed M; Zaitoun, Mostafa M

    2012-01-01

    Objective. To assess the efficacy of a new suture technique in controlling severe resistant uterine atonic postpartum hemorrhage. Patients and Methods. This is a retrospective observational study that included thirteen women with uterine atony and postpartum bleeding that did not react to usual medical management. All these women underwent compressing vertical suture technique in which the anterior and posterior walls of the uterus were attached so as to compress the uterus. The suture is transfixed at the uterine fundus, thus eliminating the risk of sutures sliding off at the uterine fundus (safety pin suture). Results. safety pin uterine compression suture was a sufficient procedure to stop the bleeding immediately in 92.2% of the women. None of the women developed complications related to the procedure. Conclusion. A new safety pin suture is a simple and effective procedure to control bleeding in patients with treatment-resistant, life-threatening atonic postpartum hemorrhage with the advantage of eliminating the risk of the sutures sliding off at the uterine fundus.

  17. Autoadjustable sutures and modified seldinger technique applied to laparoscopic jejunostomy.

    Science.gov (United States)

    Pili, Diego; Ciotola, Franco; Riganti, Juan Martín; Badaloni, Adolfo; Nieponice, Alejandro

    2015-02-01

    This is a simple technique to be applied to those patients requiring an alternative feeding method. This technique has been successfully applied to 25 patients suffering from esophageal carcinoma. The procedure involves laparoscopic approach, suture of the selected intestinal loop to the abdominal wall and jejunostomy using Seldinger technique and autoadjustable sutures. No morbidity or mortality was reported.

  18. What is the significance of tendon suture purchase?

    Science.gov (United States)

    Kim, J B; de Wit, T; Hovius, S E R; McGrouther, D A; Walbeehm, E T

    2009-08-01

    Repairs have been performed on porcine flexor tendons and subjected to tensile stress measurements to determine the effects and mechanism of core suture purchase (the length of the suture bite). Eighty-four pig trotter flexor profundus tendons were divided and repaired using four lengths of core suture purchase (1.33, 1, 0.66 and 0.33 cm) using a double modified Kessler repair (four strands, two knots) with a peripheral epitendinous suture. Tendon purchase was achieved by either bilateral equal purchase lengths or with one tendon purchase at a fixed depth of 1 cm. A separate group of tendons were incubated in blood for 24 hours to simulate the wound environment prior to testing. Tensile tests demonstrated a progressive increase of repair strength with purchase length. With the exception of the 0.33 cm group, video analysis demonstrated the mode of failure as suture failure and not due to suture pullout. Therefore, the increase in breaking strength cannot be attributed to a better grip of the tendon ends, but to the mechanical characteristics of the suture polymer. The tendency for the incubated tendons to fail more consistently by pullout rather than suture failure, particularly in the shorter purchase lengths, emphasises the importance of studying tendon purchase in vivo. The significance of ex vivo mechanical testing should be considered with caution.

  19. Suture technicians in a children's hospital emergency department.

    Science.gov (United States)

    Apolo, J O; DiCocco, D

    1988-03-01

    A program that employs technicians for suturing lacerations is presented. Careful selection of the candidates, intensive training, and ongoing monitoring of their activities have been major factors in the success of the program. The curriculum of a course for suture technicians and their job description are discussed.

  20. Evidence-based surgical wound care on surgical wound infection.

    Science.gov (United States)

    Reilly, Jaqueline

    2002-09-01

    Surgical wound infection is an important outcome indicator in the postoperative period. A 3-year prospective cohort epidemiological study of 2202 surgical patients from seven surgical wards across two hospitals was carried out using gold standard surveillance methodology. This involved following patients up as inpatients and postdischarge surveillance to 30 days by an independent observer. The results led to the development of a mathematical model for risk of clean, elective surgical wound infection. Risk of surgical wound infection was increased by smoking, higher body mass index, presence of malignancy, haematoma formation, increasing numbers of people in theatre, adherent dressing usage, and higher times to suture removal (P<0.05). The results show that this type of surveillance is an effective way of collecting accurate data on wound infection rates. It was noted that patient care practices affected the surgical wound infection rate and the surveillance was used to facilitate the adoption of evidence-based practice, through recommendations for clean surgery, to reduce the risk from extrinsic risk factors for wound infection. As a result of the implementation of this evidence-based practice there was a significant reduction (P<0.05) in the clean wound infection rate.

  1. A seam that sutures the biological to the aesthetic I and II

    Directory of Open Access Journals (Sweden)

    Aliza Shvarts

    2014-01-01

    Full Text Available A seam that sutures the biological to the aesthetic I and II (fat on paper, 2012 are part of a series of prints made with different fats, oils, and other organic materials that explore the skin as a site and surface of reproduction. The diptych stems from Aliza Shvarts interest in printmaking as an exercise of reproductive capacity, the copy as an index of lost origin, and the seam as an eroticized jointure of historically feminized labor.

  2. Evaluation of cosmetic appearance of herniotomy wound scars in African children: Comparison of tissue glue and subcuticular suturing

    Directory of Open Access Journals (Sweden)

    Ademuyiwa A

    2009-01-01

    Full Text Available Aim: To evaluate the cosmetic appearance of herniotomy wound scars closed using either the tissue glue or subcuticular suturing technique. Materials and Methods: Prospective randomised control study; randomisation into tissue glue and suturing groups. Ethical clearance obtained. Cosmetic outcome were based on visual analogue scale by parents and Hollander wound evaluation scale by a Plastic Surgeon blinded to the wound closure method. Results: Fifty one wounds were evaluated, 26 in the tissue glue group and 25 in the suturing group. Parents′ evaluation using Visual Analogue scale (VAS showed that in the suturing group, 17 parents (68% gave a VAS of 8cm while six parents (24% gave a score of 7cm. Two parents (8% gave a score of 9cm. In the tissue glue group, 22 parents (84.6% scored the scar of their children as 8 or 9cm on the VAS while four parents (15.4% gave a score of 7cm. The median VAS was 8cm for both groups with a range of 7 to 9cm. The Chi- square test showed that the parents preferred tissue glue compared with subcuticular suturing (X2 = 7.90, P < 0.05. The Hollander Wound Evaluation Scale (HWES used by Plastic Surgeon showed 21 herniotomy wounds (84% had a score of 6 in the suturing group while four wounds (16% had a score of 5. In the tissue glue group, 19 wounds (73% had a score of 6, six wounds (23.1% had a score of 5 and a patient (3.8% had a score of 4. The median score is 6 for both groups. There was no statistically significant difference between both groups (X 2 = 1.481, P = 0.393. Conclusion: This study has shown that the cosmetic outcome of wound closure using the tissue glue technique and subcuticular suturing technique are similar.

  3. Development of Absorbable, Antibiotic-Eluting Sutures for Ophthalmic Surgery

    Science.gov (United States)

    Kashiwabuchi, Fabiana; Parikh, Kunal S.; Omiadze, Revaz; Zhang, Shuming; Luo, Lixia; Patel, Himatkumar V.; Xu, Qingguo; Ensign, Laura M.; Mao, Hai-Quan; Hanes, Justin; McDonnell, Peter J.

    2017-01-01

    Purpose To develop and evaluate an antibiotic-eluting suture for ophthalmic surgery. Methods Wet electrospinning was used to manufacture sutures composed of poly(L-lactide), polyethylene glycol (PEG), and levofloxacin. Size, morphology, and mechanical strength were evaluated via scanning electron microscopy and tensile strength, respectively. In vitro drug release was quantified using high performance liquid chromatography. In vitro suture activity against Staphylococcus epidermidis was investigated through bacterial inhibition studies. Biocompatibility was determined via histological analysis of tissue sections surrounding sutures implanted into Sprague-Dawley rat corneas. Results Sutures manufactured via wet electrospinning were 45.1 ± 7.7 μm in diameter and 0.099 ± 0.007 newtons (N) in breaking strength. The antibiotic release profile demonstrated a burst followed by sustained release for greater than 60 days. Increasing PEG in the polymer formulation, from 1% to 4% by weight, improved drug release without negatively affecting tensile strength. Sutures maintained a bacterial zone of inhibition for at least 1 week in vitro and elicited an in vivo tissue reaction comparable to a nylon suture. Conclusions There is a need for local, postoperative delivery of antibiotics following ophthalmic procedures. Wet electrospinning provides a suitable platform for the development of sutures that meet size requirements for ophthalmic surgery and are capable of sustained drug release; however, tensile strength must be improved prior to clinical use. Translational Relevance No antibiotic-eluting suture exists for ophthalmic surgery. A biocompatible, high strength suture capable of sustained antibiotic release could prevent ocular infection and preclude compliance issues with topical eye drops. PMID:28083445

  4. Comparative Study of High Powerful Magnet with Conventional Repair of Suture in the Intestinal Anastomosis of Rats

    Directory of Open Access Journals (Sweden)

    Marjan Joudi

    2016-02-01

    Full Text Available Background In this study, given the importance of gastrointestinal anastomosis in surgical procedures, attempts have been made to compare the results of employing magnetic compression anastomosis and magnetic coils in intestinal anastomosis of rats. Materials and Methods This study was an experimental trial on 60 rats which had been randomly divided into two experiment (30 and control (30 groups. First, the rat intestine was cut off from a relatively fixed point and then magnet anastomosis was performed at the both ends of bowel in the control group and manual suture in the experiment group.  Anastomosis was then examined 10 days after the surgery for possible complications with a histological analysis of the indices of tissue repair. Results The mean time required for performing anastomosis of the rat intestine was 735 and 366 seconds for the control and experiment groups, respectively. Also, the laparotomy performed 10 days after the first operation did not show any significant difference between two groups in terms of surgical complications such as infiltration factor of inflammatory cell and fibroblast activity (P>0.05. The microscopic examination indicated that the tissue reaction in the anastomosis site was better in terms of tissue repair of neo-angiogenesis intestine and collagen deposition in the magnet group(P>0.05.   Conclusion Given the shorter duration of the anastomosis by magnets and more favorable histological results reported in the experiment group, as well as the lack of any significant difference in complications of the two techniques, magnetic compressive anastomosis can be used as a new technique for intestinal surgeries and pertaining anastomosis. Although, we recommend that study will be done with large sample size to obtain reliable results.

  5. Frontoorbital advancement in coronal suture craniosynostosis: a ...

    African Journals Online (AJOL)

    due to cerebral atrophy), ocular ... of the contralateral frontoparietal region. ... As frontoorbital deformity represents the central area of ... The goal of the surgical procedure was to remove ... The frontal and temporal lobes of the brain were gently.

  6. Foreign body granulomas in the left main bronchus resulting from the sutures for esophageal cancer surgery: the report of two cases

    Institute of Scientific and Technical Information of China (English)

    JIAO Yang; SHANG Yan; LI Qiang; WANG Yang; WU Ning; WANG Qin; WANG Xiang-qi; XIA Ying

    2012-01-01

    In this report,we present two cases of bronchial foreign body granulomas caused by the suture ties used in bronchial surgery for esophageal cancer.Both of them was hospitalized as “tumor transfer or an invasion”,but pathological examination of the neoplasms indicated an inflammatory granuloma showing reaction to the foreign body,These two cases give us an attention that the neoplasms in tracheal or bronchial was not only the invasion or transfer of the primary tumor,but also the possibility of grenuloma development due to the surgical sutures.

  7. Ectocranial suture fusion in primates: pattern and phylogeny.

    Science.gov (United States)

    Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I

    2014-03-01

    Patterns of ectocranial suture fusion among Primates are subject to species-specific variation. In this study, we used Guttman Scaling to compare modal progression of ectocranial suture fusion among Hominidae (Homo, Pan, Gorilla, and Pongo), Hylobates, and Cercopithecidae (Macaca and Papio) groups. Our hypothesis is that suture fusion patterns should reflect their evolutionary relationship. For the lateral-anterior suture sites there appear to be three major patterns of fusion, one shared by Homo-Pan-Gorilla, anterior to posterior; one shared by Pongo and Hylobates, superior to inferior; and one shared by Cercopithecidae, posterior to anterior. For the vault suture pattern, the Hominidae groups reflect the known phylogeny. The data for Hylobates and Cercopithecidae groups is less clear. The vault suture site termination pattern of Papio is similar to that reported for Gorilla and Pongo. Thus, it may be that some suture sites are under larger genetic influence for patterns of fusion, while others are influenced by environmental/biomechanic influences. Copyright © 2013 Wiley Periodicals, Inc.

  8. Deep Infections After Syndesmotic Fixation With a Suture Button Device.

    Science.gov (United States)

    Fantry, Amanda J; O'Donnell, Seth W; Born, Chris T; Hayda, Roman A

    2017-05-01

    Suture button devices such as the TightRope (Arthrex, Naples, Florida) have been increasingly used for syndesmotic fixation of ankle fractures. Despite proposed advantages, prior studies have shown equivalent outcomes, with a theoretical decreased need for removal of hardware. Complications of suture button fixation of syndesmotic instability may be underreported and include lateral suture knot inflammation with or without granuloma formation, infection, aseptic osteolysis with widening of the tibial drill tunnels, heterotopic ossification, and osteomyelitis. In this case series, the authors review the current literature and describe 3 patients with TightRope fixation for syndesmotic instability who developed deep infection. The authors believe that braided suture within suture button devices may provide an environment conducive to the propagation of infection across the syndesmotic fixation tract. Evidence of suture button migration or osteolysis of the TightRope tract should prompt an infectious workup and removal of hardware. If there is concern for infection associated with the TightRope, the authors recommend removing both metallic buttons and the entirety of the suture to prevent harboring a nidus for further infection. [Orthopedics. 2017; 40(3):e541-e545.]. Copyright 2017, SLACK Incorporated.

  9. Cutaneous endometriosis--Surgical presentations of a gynaecological condition.

    Science.gov (United States)

    Chiang, David T; Teh, Wan T

    2006-11-01

    Endometriosis is a common gynaecological condition; cutaneous endometriosis is a subtype of endometriosis. Although cutaneous endometriosis involving the abdominal wall is not common, preoperative diagnosis of cutaneous endometriosis can be easily mistaken for a suture granuloma, lipoma, abscess, cyst or hernia. We report two common surgical presentations of this gynaecological condition.

  10. Punctal Occlusion with Prolene Suture Material in the Patients with ...

    African Journals Online (AJOL)

    2017-07-26

    Jul 26, 2017 ... MGM Medical College and Hospital, Kamothe, Navi Mumbai, India ... Results: Punctal occlusion has been shown to improve the objective and subjective ..... Schein OD, Munoz B, Tielsch JM, Bandeen-Roche K, West S.

  11. [Surgical treatment of patients with acute abscessed and phlegmonous lactation mastitis].

    Science.gov (United States)

    Oskretkov, V I; Kokin, E F

    2001-01-01

    Under analysis were results of surgical treatment of 256 patients with abscessed and phlegmonous acute lactation mastitis. Radical primary surgical treatment of the purulent cavities allowed prevention of further progression of the inflammation in the mammary gland. The use of the low frequency ultrasound for treatment of the wound allowed to quicker arrest the acute inflammatory process in the tissues of the mammary gland surrounding the purulent cavity. In cases with diffuse purulent acute lactation mastitis it is necessary to take into attention the tension of the suture threads when fulfilling the secondary surgical treatment of the wound and putting in the running secondary early suture.

  12. "Nara" knot for suturing of cleft lip in children to make removal easy

    Directory of Open Access Journals (Sweden)

    Obaidullah

    2006-01-01

    Full Text Available Cleft patients usually go through a lifetime of repeated hospital admissions and multiple procedures. Suture removal at a tender age and on a sensitive area like the lip becomes a challenge for the nursing staff. It is also emotionally demanding on the part of the parents. Hence, in most centres these patients are at least sedated if not anaesthetised. We have been using a simple knot and running prolene material so that undoing of the knot becomes easy and suture removal more or less atraumatic. We would like to share our experience with readers through this article. An analysis of 53 cleft lip repairs has shown that this knot is safe and easily removable.

  13. Automation of a suturing device for minimally invasive surgery.

    Science.gov (United States)

    Göpel, Tobias; Härtl, Felix; Schneider, Armin; Buss, Martin; Feussner, Hubertus

    2011-07-01

    In minimally invasive surgery, hand suturing is categorized as a challenge in technique as well as in its duration. This calls for an easily manageable tool, permitting an all-purpose, cost-efficient, and secure viscerosynthesis. Such a tool for this field already exists: the Autosuture EndoStitch(®). In a series of studies the potential for the EndoStitch to accelerate suturing has been proven. However, its ergonomics still limits its applicability. The goal of this study was twofold: propose an optimized and partially automated EndoStitch and compare the conventional EndoStitch to the optimized and partially automated EndoStitch with respect to the speed and precision of suturing. Based on the EndoStitch, a partially automated suturing tool has been developed. With the aid of a DC motor, triggered by a button, one can suture by one-fingered handling. Using the partially automated suturing manipulator, 20 surgeons with different levels of laparoscopic experience successfully completed a continuous suture with 10 stitches using the conventional and the partially automated suture manipulator. Before that, each participant was given 1 min of instruction and 1 min for training. Absolute suturing time and stitch accuracy were measured. The quality of the automated EndoStitch with respect to manipulation was tested with the aid of a standardized questionnaire. To compare the two instruments, t tests were used for suturing accuracy and time. Of the 20 surgeons with laparoscopic experience (fewer than 5 laparoscopic interventions, n=9; fewer than 20 laparoscopic interventions, n=7; more than 20 laparoscopic interventions, n=4), there was no significant difference between the two tested systems with respect to stitching accuracy. However, the suturing time was significantly shorter with the Autostitch (P=0.01). The difference in accuracy and speed was not statistically significant considering the laparoscopic experience of the surgeons. The weight and size of the

  14. Use of Absorbable Sutures in Canine Carotid Arteries

    OpenAIRE

    Rey, Alejandro R.; Carrillo-Farga, Joaquin; Velasco, Carlos O.; Valencia, Martin O.V.

    1990-01-01

    To study the functional and microstructural characteristics of polydioxanone sutures in vascular surgery, we created 48 vascular anastomoses in the right and left common carotid arteries of 24 mongrel dogs. In each animal, polydioxanone sutures were used in 1 carotid artery, and polypropylene sutures were used in the contralateral carotid artery. Twelve groups of 2 animals each were then formed. The 1st group was observed for 1 month, the 2nd for 2 months, the 3rd for 3 months, and so on unti...

  15. Percutaneous suturing of the ruptured Achilles tendon with endoscopic control.

    Science.gov (United States)

    Doral, Mahmut Nedim; Bozkurt, Murat; Turhan, Egemen; Ayvaz, Mehmet; Atay, Ozgür Ahmet; Uzümcügil, Akin; Leblebicioğlu, Gürsel; Kaya, Defne; Aydoğ, Tolga

    2009-08-01

    A prospective study of modified percutaneous Achilles tendon repair performed between 1999 and 2005 under local infiltration anesthesia is presented; the study evaluated the results of percutaneous repair technique by visualization of the synovia under endoscopic control, followed by early functional postoperative treatment for surgical intervention of acute Achilles tendon ruptures. Sixty-two patients (58 males, 4 females, mean age 32) were treated by percutaneous suturing with modified Bunnel technique under endoscopic control within 10 days after acute total rupture. Physiotherapy was initiated immediately after the operation and patients were encouraged to weight-bearing ambulation with a walking brace-moon boot as tolerated. Full weight-bearing was allowed minimum after 3 weeks postoperatively without brace. The procedure was tolerated in all patients. There were no significant ROM limitation was observed. Two patients experienced transient hypoesthesia in the region of sural nerve that spontaneously resolved in 6 months. Fifty-nine patients (95%) including professional athletes returned to their previous sportive activities, while 18 of them (29%) had some minor complaints. The interval from injury to return to regular work and rehabilitation training was 11.7 weeks (10-13 weeks). At the latest follow-up (mean: 46 months; range: 12-78 months), all the patients had satisfactory results with a mean American Orthopedic Foot and Ankle Society's ankle-hindfoot score of 94.6. No re-ruptures, deep venous thrombosis or wound problems occurred. The proposed method offers a reasonable treatment option for acute total Achilles tendon rupture with a low number of complications. The rerupture rate and return to preinjury activities are comparable to open and percutaneous without endoscopic control procedures.

  16. Internal fixation of displaced inferior pole of the patella fractures using vertical wiring augmented with Krachow suturing.

    Science.gov (United States)

    Oh, Hyoung-Keun; Choo, Suk-Kyu; Kim, Ji-Wan; Lee, Mark

    2015-12-01

    We present the surgical technique of separate vertical wiring for displaced inferior pole fractures of the patella combined with Krachow suture and report the surgical outcomes. Between September 2007 to May 2012, 11 consecutive patients (mean age, 54.6 years) with inferior pole fractures of the patella (AO/OTA 34-A1) were retrospectively enrolled in this study. Through longitudinal incision, all patients underwent open reduction and internal fixation by separate vertical wiring combined with Krackow suture. The range of motion, loss of fixation, and Bostman score were primary outcome measures. The union time was 10 weeks after surgery on average (range: 8-12). No patient had nonunion, loss of reduction and wire breakage. There was no case of wound problem and irritation from the implant. At final follow-up, the average range of motion arc was 129.4° (range: 120-140). The mean Bostman score at last follow-up was 29.6 points (range: 28-30) and graded excellent in all cases. Separate vertical wiring combined with Krackow suture for inferior pole fractures of the patella is a useful technique that is easy to perform and can provide stable fixation with excellent results in knee function. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Comparative analysis on arthroscopic sutures of large and extensive rotator cuff injuries in relation to the degree of osteopenia

    Directory of Open Access Journals (Sweden)

    Alexandre Almeida

    2015-02-01

    Full Text Available OBJECTIVE: To analyze the results from arthroscopic suturing of large and extensive rotator cuff injuries, according to the patient's degree of osteopenia.METHOD: 138 patients who underwent arthroscopic suturing of large and extensive rotator cuff injuries between 2003 and 2011 were analyzed. Those operated from October 2008 onwards formed a prospective cohort, while the remainder formed a retrospective cohort. Also from October 2008 onwards, bone densitometry evaluation was requested at the time of the surgical treatment. For the patients operated before this date, densitometry examinations performed up to two years before or after the surgical treatment were investigated. The patients were divided into three groups. Those with osteoporosis formed group 1 (n = 16; those with osteopenia, group 2 (n = 33; and normal individuals, group 3 (n = 55.RESULTS: In analyzing the University of California at Los Angeles (UCLA scores of group 3 and comparing them with group 2, no statistically significant difference was seen (p = 0.070. Analysis on group 3 in comparison with group 1 showed a statistically significant difference (p = 0.027.CONCLUSION: The results from arthroscopic suturing of large and extensive rotator cuff injuries seem to be influenced by the patient's bone mineral density, as assessed using bone densitometry.

  18. [Artefacts in the CT scan caused by surgical clips and central venous catheters and the use of new materials].

    Science.gov (United States)

    Schadel, A; Böttcher, H D; Haverkamp, U; Wagner, W; Schmilowski, G M

    1984-03-01

    When metal clips and venous catheters have been used the computerized tomography shows artifacts, which make it computerized tomography shows artifacts, which make it difficult to have a reliable and accurate diagnosis, because the X- raying of the metal clips and the venous catheter gives radiating lines, so called streaking. We have tested new materials for the metal clips and a new polymer to replace the substance of the venous catheter with the intention that the materials should have the same density as the normal tissues. With a new metal for the clips and a new polymer for the venous catheters, mixed with metal ions, the computerized tomography does not show streaking.

  19. Selective suture cutting for control of astigmatism following cataract surgery

    Directory of Open Access Journals (Sweden)

    Bansal R

    1992-01-01

    Full Text Available Use of 10-0 monofilament nylon in ECCE cataract surgery leads to high with the rule astigmatism. Many intraoperative and post operative methods have been used to minimise post operative astigmatism. We did selective suture cutting in 38 consecutive patients. Mean keratometric astigmatism at three and six weeks post operative was 5.76 and 5.42 dioptres (D respectively. 77.5% of eyes had astigmatism above 2 D. Selective suture cutting along the axis of the plus high cylinder was done after six weeks of surgery. Mean post suture cutting keratometric astigmatism was 3.3 D and 70% of the eyes had astigmatism below 2 D. After 3 months of surgery mean keratometric astigmatism was reduced to 1.84 D. Axis of the astigmatism also changed following suture cutting. 40% of the eyes showed improvement in their Snellen acuity following reduction in the cylindrical power.

  20. Corneoscleral abscess resulting from a broken suture after cataract surgery.

    Science.gov (United States)

    Cameron, J A; Huaman, A

    1994-01-01

    An 82-year-old man had pain and decreased vision in his right eye 15 months after uncomplicated cataract surgery. Examination revealed a large corneoscleral abscess with a 2 mm x 1 mm area of fluorescein staining at the base of a broken protruding 10-0 nylon suture. Streptococcus pneumoniae was isolated from both the suture and base of the ulcer. Despite intensive topical, subconjunctival, and systemic antibiotics, a large corneal perforation developed, necessitating a 10 mm tectonic penetrating keratoplasty. Long-term follow-up of patients after cataract surgery is important and should include an inspection of the limbal wound and removal of loose or broken exposed sutures. Suture-related complications will be eliminated if clinical studies prove the safety and efficacy of sutureless cataract surgery.

  1. Prenatal ultrasound parameters in single-suture craniosynostosis

    NARCIS (Netherlands)

    M.J. Cornelissen (Martijn); Apon, I. (Inge); J.J.N.M. van der Meulen (Jacques); I.A.L. Groenenberg (Irene); Kraan – van der Est, M.N. (Mieke N.); I.M.J. Mathijssen (Irene); G.J. Bonsel (Gouke); Cohen – Overbeek, T.E. (Titia E.)

    2017-01-01

    textabstractIntroduction: Although single-suture craniosynostosis is diagnosed sporadically during pregnancy, timely referral is critical for its treatment. Additionally, craniosynostosis leads to increased maternofetal trauma during birth. In the Netherlands, 95% of pregnant women receive a

  2. Electromyographic correlates of learning during robotic surgical training in virtual reality.

    Science.gov (United States)

    Suh, Irene H; Mukherjee, Mukul; Schrack, Ryan; Park, Shi-Hyun; Chien, Jung-Hung; Oleynikov, Dmitry; Siu, Ka-Chun

    2011-01-01

    The purpose of this study was to investigate the muscle activation and the muscle frequency response of the dominant arm muscles (flexor carpi radialis and extensor digitorum) and hand muscles (abductor pollicis and first dorsal interosseous) during robotic surgical skills training in a virtual environment. The virtual surgical training tasks consisted of bimanual carrying, needle passing and mesh alignment. The experimental group (n=5) was trained by performing four blocks of the virtual surgical tasks using the da Vinci™ surgical robot. During the pre- and post-training tests, all subjects were tested by performing a suturing task on a "life-like" suture pad. The control group (n=5) performed only the suturing task without any virtual task training. Differences between pre- and post-training tests were significantly greater in the virtual reality group, as compared to the control group in the muscle activation of the hand muscle (abductor pollicis) for both the suture tying and the suture running (pvirtual reality leads to specific changes in neuromotor control of robotic surgical tasks.

  3. Arthroscopic suture fixation in patients with a tibial intercondylar eminence fracture using a simple device to penetrate the anterior cruciate ligament

    Directory of Open Access Journals (Sweden)

    Masato Aratake

    2014-04-01

    Full Text Available Displaced tibial intercondylar eminence fractures require early reduction and stable fixation to prevent nonunion, knee instability, and a lack of extension. Many types of surgical procedure are recommended including arthrotomy or an arthroscopic technique to stabilize the fracture segment using Kirschner wire, screws, staples, and suture fixation. However, contemporary arthroscopic techniques and devices can facilitate intra-articular surgery and have been applied to the treatment of this fracture. In our current report, we describe a simple suture fixation method under arthroscopy for the treatment of tibial intercondylar eminence fractures. We treated eight knees of eight patients. One patient had a Type II fracture and seven patients had a Type III fracture according to Meyer's classification. Following the arthroscopic inspection of concomitant injuries, debridement of hematoma, and reduction of the fragment, two nonabsorbable sutures (Ethibond No. 2, Johnson & Johnson, Somerville, NJ, USA were advanced through the suture passer device, which is used to penetrate the anterior cruciate ligament (ACL near to the insertion site of the displaced fragment. Two surgical sutures were pulled out by the suture retriever from the anterior proximal tibia hole and were fixed to the tibia cortex bone with a double-spike plate. At follow-up, radiographic examinations showed that bone union was achieved in all cases. All but one patient could resume normal activities with no restrictions and no ligamentous instability. All knees had a negative Lachman's test and showed a gain of stable ligament function by KT2000 arthrometer evaluation. One patient had an insignificant extension limitation and experienced slight pain after walking but these symptoms were minimal. In conclusion current arthroscopic surgery techniques for tibial intercondylar fractures can be easily performed and reproducibly achieve secure fixation and early mobilization of the knee.

  4. A comparative study of continuous versus interrupted suturing for repair of episiotomy or second degree perineal tear

    Directory of Open Access Journals (Sweden)

    Lopamudra Jena

    2015-02-01

    Full Text Available Background: This study has been taken up to assess the effects of continuous versus interrupted suturing methods on the incidence of short and long term postpartum maternal morbidity experienced by women following repair of episiotomy or second-degree perineal tears after vaginal birth. Methods: This comparative prospective study was conducted in department of obstetrics and gynaecology of S.C.B. medical college, Cuttack, Odisha to compare continuous suturing technique with interrupted method for the repair of episiotomy and second degree perineal tear following vaginal delivery in 211 women. One group was repaired with continuous non-locking sutures involving the vaginal mucosa, perineal muscles and subcutaneous tissue for skin and other group had continuous locking stitch of vaginal mucosa, interrupted sutures in perineal muscles and interrupted transcutaneous stitches for skin. Identical suture material (catgut supplied by the government was used for both the groups. The mothers were interviewed on the 2nd, 10th and 42nd day following repair regarding pain perception with lying, walking and sitting posture using Visual Analogue Scale (VAS. Results: The pain score measured by VAS on 2nd day showed mild to moderate pain in continuous group compared to moderate and severe pain in interrupted group (P = 0.008 in lying position and (P = 0.000 in sitting and walking position. On 10th day no difference in perception in lying position (P = 0.571 but more subjects of interrupted group had pain in sitting and walking position (P = 0.05. On 42nd day no difference in pain perception in both groups was seen (P = 1.000. There was no difference in wound dehiscence in both the groups (P = 0.361. Subjects in the interrupted group had greater complains of dyspareunia compared to subjects in continuous group (P = 0.009. Less length of suture were required in the continuous group (P = 0.000. Conclusions: Continuous suturing technique for repair of episiotomy and

  5. Transtracheal single-point stent fixation in posttracheotomy tracheomalacia under cone-beam computer tomography guidance by transmural suturing with the Berci needle – a perspective on a new tool to avoid stent migration of Dumon stents

    Directory of Open Access Journals (Sweden)

    Hohenforst-Schmidt W

    2015-05-01

    fixation with different techniques in a patient with severe posttracheotomy TM and strongly reduced mobility of the vocal cords due to Parkinson’s disease. The combined approach with simultaneous Dumon stenting and endoluminal transtracheal externalized suture under cone-beam computer tomography guidance with the Berci needle was by far the fastest approach compared to a (not performed surgical intervention, or even purely endoluminal suturing through the rigid bronchoscope. The duration of the endoluminal transtracheal externalized suture was between 5 minutes and 9 minutes with the Berci needle; the pure endoluminal approach needed 51 minutes. The alternative of tracheobronchoplasty was refused by the patient. In general, 180 minutes for this surgical approach is calculated. The costs of the different approaches are supposed to vary widely due to the fact that in Germany 1 minute in an operation room costs on average approximately 50–60€ inclusive of taxes. In our own hospital (tertiary level, it is nearly 30€ per minute in an operation room for a surgical approach. Calculating an additional 15 minutes for patient preparation and transfer to wake-up room, therefore a total duration inside the investigation room of 30 minutes, the cost per flexible bronchoscopy is per minute on average less than 6€. Although the Dumon stenting requires a set-up with more expensive anesthesiology accompaniment, which takes longer than a flexible investigation estimated at 1 hour in an operation room, still without calculation of the costs of the materials and specialized staff that the surgical approach would consume at least 3,000€ more than a minimally invasive approach performed with the Berci needle. This difference is due to the longer time of the surgical intervention which is calculated at approximately 180 minutes in comparison to the achieved non-surgical approach of 60 minutes in the operation suite.Keywords: stent, airway, cone-beam computer tomography, Berci

  6. Failure strengths of repair devices versus meniscus suturing techniques

    OpenAIRE

    Asik, Mehmet; Sener, Nadir; Dikici, Fatih; Sen, Cengiz

    2004-01-01

    Objectives: The purpose of this study was to compare the load to failure of different common suturing techniques with that of repair devices. Methods: Seventy-one calf medial menisci were cut to simulate peripheral longitudinal tears and repaired using either one of the two suture techniques or one of the seven repair devices. Then the two parts of the meniscus were pulled using an Instron tensometer until failure occurred. The techniques and repair devices tested included vertical (0 PDS,...

  7. Fixation in laparoscopic incisional hernia repair: Suture versus tacks

    Directory of Open Access Journals (Sweden)

    Adil Bangash

    2013-01-01

    Full Text Available Aims and Objectives: To compare the frequency of complications of laparoscopic repair of incisional hernia using fixation of mesh with transabdominal sutures tacks. Materials and Methods: This study was conducted as part of an interventional multicenter trial at the Rehman Medical Institute, Peshawar, Peshawar Institute of Medical Sciences, and Pakistan Institute of Medical Science, Islamabad, from the 1 st of November 2008 till 31 st October 2011. The frequency of complications was calculated as the measure of comparing two methods of fixation in laparoscopic repair of incisional hernia using the IPOM technique. These patients were admitted via the outpatient department and their demographic data were collected on a pro forma basis. Forty-five patients were alternately placed in either group, and group I comprised patients with a ventral hernia that was fixed using spiral tacks whereas the other group was fixed with transabdominal sutures. A polytetraflouroethylene (Dual R mesh was applied in all cases. All data were collected onthe individual pro forma of each patient and was loaded on the SPSS R version 13.0. Results: The BMI in both groups was similar (P=0.94 The mean hospital stay was higher in the PTFE mesh group but the values were not significant (P=1.22.No perioperative death was observed in either group. One patient (2.2% from group I was readmitted with varying complaints and was diagnosed as having subacute intestinal obstruction (P>0.05. A higher but insignificant recurrence rate was observed in the polyester group over a one-year period of follow-up. Three patients (6.6% were diagnosed with recurrences in group I. Instead the PTFE group had a similar recurrence rate recurrence (P=1.00. Conclusion: The rate of recurrence in this study showed no significant difference by either mode of fixation. But statistically significant pain scores and increased operative time to fixation favors the use of tacks that limits to the few inner

  8. Development of advanced antimicrobial and sterilized plasma polypropylene grafted muga (Antheraea assama) silk as suture biomaterial.

    Science.gov (United States)

    Gogoi, Dolly; Choudhury, Arup Jyoti; Chutia, Joyanti; Pal, Arup Ratan; Khan, Mojibur; Choudhury, Manash; Pathak, Pallabi; Das, Gouranga; Patil, Dinkar S

    2014-04-01

    Surface modification of silk fibroin (SF) materials using environmentally friendly and non-hazardous process to tailor them for specific application as biomaterials has drawn a great deal of interest in the field of biomedical research. To further explore this area of research, in this report, polypropylene (PP) grafted muga (Antheraea assama) SF (PP-AASF) suture is developed using plasma treatment and plasma graft polymerization process. For this purpose, AASF is first sterilized in argon (Ar) plasma treatment followed by grafting PP onto its surface. AASF is a non-mulberry variety having superior qualities to mulberry SF and is still unexplored in the context of suture biomaterial. AASF, Ar plasma treated AASF (AASFAr) and PP-AASF are subjected to various characterization techniques for better comparison and the results are attempted to correlate with their observed properties. Excellent mechanical strength, hydrophobicity, antibacterial behavior, and remarkable wound healing activity of PP-AASF over AASF and AASFAr make it a promising candidate for application as sterilized suture biomaterial.

  9. LONG TERM OUTCOME AFTER OPEN INGUINAL HERNIA REPAIR BY CONTINOUS SUTURE VERSUS INTERRUPTED SUTURE TO FIX THE MESH

    Directory of Open Access Journals (Sweden)

    Kuldeep Raj

    2013-12-01

    Full Text Available ABSTRACT : BACK GROUND: Meshplasty is a must in adult patient. P ro lene mesh is widely used and is fixed with prolene suture as well. The aim of this study was to compare the quality of life and pain felt in postoperative phase for 2 years after open inguinal hernia repair by i nterrupted sutures versus continous sutures. METHODS: From Jan 2010 – Dec 2010 , 15 patients were operated using prolene mesh and this mesh was fixed with prolene 2’0’ in continous way starting at pubic tubercle and continues along inguinal ligament beyond deep inguinal r ing and then lateral to deep inguinal ring and above it along conjoint tendon and ends at the pubic tubercle with only single knot , and were compared with 15 patients who underwent same procedure using prolene mesh fixed with p rolene suture but in interrupted way and this creates a lot of knots ( 10 - 12 Av erage . Patients were examined and followed in OPD for 2 years. RESULTS : In the long run the patients treated with continous suture were having comparatively better qua lity of life with less pain and less foreign body sensation of mesh and knots & knots were not felt percutaneously, where as in routine procedure patients were complaining of painful sensation due to pressing of knots in subcutaneous space. CONCLUSION : In this study the quality of life in open hernia repair with prolene suture using continous suture technique versus interrupted suture technique is definitely better , less pain ful and feeling less foreign body sensation.

  10. Free Gingival Grafting; Epiglu VS. Silk Thread Suturing: A Comparative Study

    Directory of Open Access Journals (Sweden)

    M. Paknejad

    2004-06-01

    Full Text Available Statement of the Problem: The routine procedure for immobilization of free gingival graft (FGG is suturing. Due to the successful application of tissue adhesives their employment has also become the subject of interest.Purpose: The aim of present clinical trial was to compare using Epiglu (E.g versus silk thread suturing in FGG.Materials and Methods: This study was a split mouth clinical trial. The study group comprised of 12 patients with symmetrical loss of attached gingiva whom were referred to Faculty of Dentistry, Tehran University of Medical science. In test group, the gingivalgraft were placed on cellophane and after applying one drop of Eg then placed in the proper position. In control group silk suturing was used.Results: The degree of pain had no significant differences in two groups (P>0.05. The rate of bleeding was insignificant at the first day (P=0.5, but in the second (P=0.0425and the third day (P=0.0313 less bleeding was observed in the test group. 10 days after the surgery, grafts in the test group had better healing (P=0.0425, while 3 month later no significant differences observed (P>0.05. Although the mean tissue shrinkage were 41%and 38% for control and test group respectively, Wilcoxon test showed no significant differences 30 days after surgery (P>0.05. The tissue shrinkage also was not significant 3 months after surgery. In addition, no displacement, infection or hypersensitivity werenoted in either of two groups.Conclusion: In FGG, Epiglu is more effective than suturing.

  11. Craniosynostosis of coronal suture in twist1 mice occurs through endochondral ossification recapitulating the physiological closure of posterior frontal suture.

    Science.gov (United States)

    Behr, Björn; Longaker, Michael T; Quarto, Natalina

    2011-01-01

    Craniosynostosis, the premature closure of cranial suture, is a pathologic condition that affects 1/2000 live births. Saethre-Chotzen syndrome is a genetic condition characterized by craniosynostosis. The Saethre-Chotzen syndrome, which is defined by loss-of-function mutations in the TWIST gene, is the second most prevalent craniosynostosis. Although much of the genetics and phenotypes in craniosynostosis syndromes is understood, less is known about the underlying ossification mechanism during suture closure. We have previously demonstrated that physiological closure of the posterior frontal suture occurs through endochondral ossification. Moreover, we revealed that antagonizing canonical Wnt-signaling in the sagittal suture leads to endochondral ossification of the suture mesenchyme and sagittal synostosis, presumably by inhibiting Twist1. Classic Saethre-Chotzen syndrome is characterized by coronal synostosis, and the haploinsufficient Twist1(+/-) mice represents a suitable model for studying this syndrome. Thus, we seeked to understand the underlying ossification process in coronal craniosynostosis in Twist1(+/-) mice. Our data indicate that coronal suture closure in Twist1(+/-) mice occurs between postnatal day 9 and 13 by endochondral ossification, as shown by histology, gene expression analysis, and immunohistochemistry. In conclusion, this study reveals that coronal craniosynostosis in Twist1(+/-) mice occurs through endochondral ossification. Moreover, it suggests that haploinsufficiency of Twist1 gene, a target of canonical Wnt-signaling, and inhibitor of chondrogenesis, mimics conditions of inactive canonical Wnt-signaling leading to craniosynostosis.

  12. Craniosynostosis of coronal suture in Twist1+/- mice occurs through endochondral ossification recapitulating the physiological closure of posterior frontal suture

    Directory of Open Access Journals (Sweden)

    Bjorn eBehr

    2011-07-01

    Full Text Available Craniosynostosis, the premature closure of cranial suture, is a pathologic condition that affects 1/2000 live births. Saethre-Chotzen syndrome is a genetic condition characterized by craniosynostosis. The Saethre-Chotzen syndrome, which is defined by loss-of-function mutations in the TWIST gene, is the second most prevalent craniosynostosis. Although much of the genetics and phenotypes in craniosynostosis syndromes is understood, less is known about the underlying ossification mechanism during suture closure. We have previously demonstrated that physiological closure of the posterior frontal (PF suture occurs through endochondral ossification. Moreover, we revealed that antagonizing canonical Wnt signaling in the sagittal suture leads to endochondral ossification of the suture mesenchyme and sagittal synostosis, presumably by inhibiting Twist1. Classic Saethre-Chotzen syndrome is characterized by coronal synostosis, and the haploinsufficient Twist1+/- mice represents a suitable model for studying this syndrome. Thus, we seeked to understand the underlying ossification process in coronal craniosynostosis in Twist1+/- mice. Our data indicate that coronal suture closure in Twist1+/- mice occurs between postnatal day 9 to 13 by endochondral ossification, as shown by histology, gene expression analysis and immunohistochemistry. In conclusion, this study reveals that coronal craniosynostosis in Twist1+/- mice occurs through endochondral ossification. Moreover, it suggests that haploinsufficency of Twist1 gene, a target of canonical Wnt-signaling, and inhibitor of chondrogenesis, mimics conditions of inactive canonical Wnt-signaling leading to craniosynostosis.

  13. Cataract Surgery after Retinal Detachment Surgery with Arruga’s Suture: Case Report

    Directory of Open Access Journals (Sweden)

    Erkan Ünsal

    2016-12-01

    Full Text Available A 56-year old female patient presented to our clinic with a complaint of low vision in her right eye. Twenty-two years earlier she had undergone a scleral buckling operation in her right eye because of retinal detachment. She indicated that vision in her right eye was good after the surgery but had recently been gradually declining. Best-corrected vision acuity was counting fingers at 1 meter in the right eye and 8/10 in the left eye. Anterior segment examination revealed stage 3 nuclear cataract in the right eye. Examination of the right eye was blurred and revealed an area of chorioretinal atrophy posterior to the equator, approximately 3 disc diameters in the peripapillary zone and about 2 disc diameters in the nasal papilla zone. Anteriorly of the equator there was an area of chorioretinal atrophy as well as a narrow, sharply demarcated, shiny 360⁰ suture with high buckling pressure, situated intraretinally but extending into the vitreous in some places. The structure was thought to be made of polyethylene. Around the suture there were retinal atrophic changes. After detailed explanation of the possible surgical complications and after obtaining informed consent, the right eye cataract was removed by phacoemulsification and a foldable intraocular lens was placed into the capsule. During the operation, we worked under low fluid pressure and as atraumatically as possible due to the possibility of intraocular pressure changes and the risk of the suture causing retinal and blood vessel tears or passing completely into the eye and causing intravitreal hemorrhage. A month after an uncomplicated surgery, the posterior segment examination demonstrated a reattached retina and the patient’s best corrected visual acuity was 6/10.

  14. SURGICAL IMPLANTATION OF COELOMIC RADIOTRANSMITTERS AND POSTOPERATIVE SURVIVAL OF CHINESE GIANT SALAMANDERS (ANDRIAS DAVIDIANUS) FOLLOWING REINTRODUCTION.

    Science.gov (United States)

    Marcec, Ruth; Kouba, Andrew; Zhang, Lu; Zhang, Hongxing; Wang, Qijun; Zhao, Hu; Jiang, Wei; Willard, Scott

    2016-03-01

    Worldwide, there are only a handful of reintroduction programs for threatened salamander species, and very few have conducted postrelease studies to examine survival, habitat selection, and dispersal. Limitations in postrelease monitoring are primarily due to size constraints of amphibians and to dimensions of the radiotransmitters available for implantation. However, due to the large size of the critically endangered Chinese giant salamander (Andrias davidianus), these animals make optimal candidates for surgical implantation of radiotransmitters prior to reintroduction or translocation. The objective of this study was to develop an anesthetic protocol using tricane methanesulfonate (MS-222) and test a surgical procedure for coelomic implantation of radiotransmitters for this species. A total of 32 Chinese giant salamanders from two age groups (Group A: 4.7 yr old, n = 16; Group B: 2.7 yr old, n = 16) were implanted with 4-g radiotransmitters designed for underwater monitoring of fish. Group A was held 16 wk before release while Group B was held 6 wk before release, and the salamanders' survival and postoperative complications recorded for the first month postrelease. Group A animals took longer to reach a surgical plane of anesthesia than did Group B animals, and this was directly correlated to mass of the animals. Postsurgery, one animal from Group B died of dehiscence before release while 83.9% animals survived after the first month in the wild. All of the animals that died postrelease were from Group B; three animals experienced dehiscence of the suture site and died while another two animals expired from trauma and fungal infection, respectively. Improvements for future studies include use of alternative suture material for closure after implantation and additional healing time of the incision.

  15. Osteolysis of the Greater Trochanter Caused by a Foreign Body Granuloma Associated with the Ethibond® Suture after Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Keiji Kamo

    2017-01-01

    Full Text Available The present case shows a case of progression of osteolysis of the greater trochanter caused by a foreign body granuloma associated with the number 5 Ethibond suture in cementless THA with the direct lateral approach that was completely healed by removal of the Ethibond suture. A 55-year-old Japanese woman with secondary osteoarthritis caused by acetabular dysplasia underwent left cementless THA with the direct lateral approach. After setting of the total hip prosthesis, the gluteus medius muscle and vastus lateralis muscle were reattached to the greater trochanter through two bone tunnels using number 5 Ethibond EXCEL sutures. The left hip pain disappeared after surgery, but the bone tunnels enlarged gradually and developed osteolysis at 10 weeks. The removal of the Ethibond sutures and debridement improved the osteolysis. Histological examination showed the granuloma reaction to a foreign body with giant cell formation. The Ethibond suture has the lowest inflammatory tissue reaction and relatively high tension strength among nonabsorbable suture materials. However, number 5 Ethibond has the potential to cause osteolysis due to a foreign body granuloma, as in the present case.

  16. Osteolysis of the Greater Trochanter Caused by a Foreign Body Granuloma Associated with the Ethibond® Suture after Total Hip Arthroplasty.

    Science.gov (United States)

    Kamo, Keiji; Kijima, Hiroaki; Okuyama, Koichiro; Seki, Nobutoshi; Yamada, Shin; Miyakoshi, Naohisa; Shimada, Yoichi

    2017-01-01

    The present case shows a case of progression of osteolysis of the greater trochanter caused by a foreign body granuloma associated with the number 5 Ethibond suture in cementless THA with the direct lateral approach that was completely healed by removal of the Ethibond suture. A 55-year-old Japanese woman with secondary osteoarthritis caused by acetabular dysplasia underwent left cementless THA with the direct lateral approach. After setting of the total hip prosthesis, the gluteus medius muscle and vastus lateralis muscle were reattached to the greater trochanter through two bone tunnels using number 5 Ethibond EXCEL sutures. The left hip pain disappeared after surgery, but the bone tunnels enlarged gradually and developed osteolysis at 10 weeks. The removal of the Ethibond sutures and debridement improved the osteolysis. Histological examination showed the granuloma reaction to a foreign body with giant cell formation. The Ethibond suture has the lowest inflammatory tissue reaction and relatively high tension strength among nonabsorbable suture materials. However, number 5 Ethibond has the potential to cause osteolysis due to a foreign body granuloma, as in the present case.

  17. Disposable circumcision suture device: clinical effect and patient satisfaction

    Directory of Open Access Journals (Sweden)

    Bo-Dong Lv

    2014-06-01

    Full Text Available In our experience patients undergoing circumcision are mostly concerned about pain and penile appearances. We conducted a prospective randomized trial to assess the benefits of a new disposable circumcision suture device (DCSD. A total of 942 patients were equally divided into three groups (conventional circumcision, Shang ring and disposable suture device group. Patients in the DCSD group were anesthetized with compound 5% lidocaine cream, the others with a 2% lidocaine penile block. Operation time, intra-operative blood loss, incision healing time, intra-operative and post-operative pain, the penile appearance and overall satisfaction degree were measured. Operation time and intra-operative blood loss were significantly lower in the Shang ring and suture device groups compared to the conventional group (P < 0.001. Intra-operative pain was less in the suture device group compared with the other two groups (P < 0.001; whereas post-operative pain was higher in the conventional group compared to the other two groups (P < 0.001. Patients in the suture device (80.57% and Shang ring (73.57% groups were more satisfied with penile appearances compared with the conventional circumcision group (20.06%, P < 0.05. Patients in suture device group also healed markedly faster than the conventional group (P < 0.01. The overall satisfaction rate was better in the suture device group (78.66% compared with the conventional (47.13% and Shang ring (50.00% groups (P < 0.05. The combination of DCSD and lidocaine cream resulted in shorter operation and incision healing times, reduced intra-operative and post-operative pain and improved patient satisfaction with the cosmetic appearances.

  18. Disposable circumcision suture device:clinical effect and patient satisfaction

    Institute of Scientific and Technical Information of China (English)

    BoDong Lv; ShiGeng Zhang; XuanWen Zhu; Jie Zhang; Gang Chen; MinFu Chen; HongLiang Shen; ZaiJun Pei; ZhaoDian Chen

    2014-01-01

    In our experience patients undergoing circumcision are mostly concerned about pain and penile appearances. We conducted a prospective randomized trial to assess the beneifts of a new disposable circumcision suture device (DCSD). A total of 942 patients were equally divided into three groups (conventional circumcision, Shang ring and disposable suture device group). Patients in the DCSD group were anesthetized with compound 5%lidocaine cream, the others with a 2%lidocaine penile block. Operation time, intra-operative blood loss, incision healing time, intra-operative and post-operative pain, the penile appearance and overall satisfaction degree were measured. Operation time and intra-operative blood loss were signiifcantly lower in the Shang ring and suture device groups compared to the conventional group (P<0.001). Intra-operative pain was less in the suture device group compared with the other two groups (P<0.001);whereas post-operative pain was higher in the conventional group compared to the other two groups (P<0.001). Patients in the suture device (80.57%) and Shang ring (73.57%) groups were more satisifed with penile appearances compared with the conventional circumcision group (20.06%, P<0.05). Patients in suture device group also healed markedly faster than the conventional group (P<0.01). The overall satisfaction rate was better in the suture device group (78.66%) compared with the conventional (47.13%) and Shang ring (50.00%) groups (P<0.05). The combination of DCSD and lidocaine cream resulted in shorter operation and incision healing times, reduced intra-operative and post-operative pain and improved patient satisfaction with the cosmetic appearances.

  19. Influence of Force and Torque Feedback on Operator Performance in a VR-Based Suturing Task

    Directory of Open Access Journals (Sweden)

    L. Santos-Carreras

    2010-01-01

    Full Text Available The introduction of Minimally Invasive Surgery (MIS has revolutionised surgical care, considerably improving the quality of many surgical procedures. Technological advances, particularly in robotic surgery systems, have reduced the complexity of such an approach, paving the way for even less invasive surgical trends. However, the fact that haptic feedback has been progressively lost through this transition is an issue that to date has not been solved. Whereas traditional open surgery provides full haptic feedback, the introduction of MIS has eliminated the possibility of direct palpation and tactile exploration. Nevertheless, these procedures still provide a certain amount of force feedback through the rigid laparoscopic tool. Many of the current telemanipulated robotic surgical systems in return do not provide full haptic feedback, which to a certain extent can be explained by the requirement of force sensors integrated into the tools of the slave robot and actuators in the surgeon’s master console. In view of the increased complexity and cost, the benefit of haptic feedback is open to dispute. Nevertheless, studies have shown the importance of haptic feedback, especially when visual feedback is unreliable or absent. In order to explore the importance of haptic feedback for the surgeon’s master console of a novel teleoperated robotic surgical system, we have identified a typical surgical task where performance could potentially be improved by haptic feedback, and investigate performance with and without this feedback. Two rounds of experiments are performed with 10 subjects, six of them with a medical background. Results show that feedback conditions, including force feedback, significantly improve task performance independently of the operator’s suturing experience. There is, however, no further significant improvement when torque feedback is added. Consequently, it is deduced that force feedback in translations improves subject

  20. Abdominal wound closure. A randomized prospective study of 571 patients comparing continuous vs. interrupted suture techniques.

    Science.gov (United States)

    Richards, P C; Balch, C M; Aldrete, J S

    1983-01-01

    A randomized, prospective study was designed to compare a continuous with an interrupted technique for closing an abdominal incision. Five hundred seventy-one patients were randomized between the closure methods and stratified as to type of wound: clean, clean-contaminated, or contaminated. In mid-line incisions, the dehiscence rate was 2.0% (5/244) for the continuous group versus 0.9% (2/229) for the interrupted group. The difference was not statistically significant. Ventral hernias formed in 2.0% (4/201) of the continuous group vs. 0.5% (1/184) of the interrupted group. The type of wound had no influence on the results. In oblique incisions, 0% (0/39) of wounds closed continuously dehised while 2% (1/50) of incisions closed interruptedly dehised. No ventral hernias formed. Further analysis of the data indicated that dehiscence was more likely related to improper surgical technique than to the method of closure. An abdominal incision could be closed with a continuous suture in approximately half the time required for placing interrupted sutures (20 vs. 40 minutes). A continuous closure is preferred because it is more expedient and because it has the same incidence of wound disruption compared with an interrupted closure. PMID:6297417

  1. Three-dimensional evaluation of the alar cinch suture after Le Fort I osteotomy.

    Science.gov (United States)

    van Loon, B; Verhamme, L; Xi, T; de Koning, M J J; Bergé, S J; Maal, T J J

    2016-10-01

    Orthognathic surgery has an influence on the overlying soft tissues of the translated bony maxillomandibular complex. Improvements in both function and facial appearance are the goals of surgery. However, unwanted changes to the soft tissues, especially in the nose region, frequently occur. The most common secondary change in the nasolabial region is widening of the alar base. Various surgical techniques have been developed to minimize this effect. The purpose of this study was to evaluate the changes in the nasal region due to orthognathic surgery, especially the alar width and nasal volume, using combined cone beam computed tomography (CBCT) and three-dimensional (3D) stereophotogrammetry datasets. Twenty-six patients who underwent a Le Fort I advancement osteotomy between 2006 and 2013 were included. From 2006 to 2010, no alar base cinch sutures were performed. From 2010 onwards, alar base cinch sutures were used. Preoperative and postoperative documentation consisted of 3D stereophotogrammetry and CBCT scans. 3D measurements were performed on the combined datasets, and the alar base width and nose volume were analyzed. No difference in alar base width or nose volume was observed between patients who had undergone an alar cinch and those who had not. Postoperatively the nose widened and the volume increased in both groups. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. Suture less 3D mesh repair of sliding inguinal hernia: a case report

    Directory of Open Access Journals (Sweden)

    Abhijit Bagul

    2016-07-01

    Full Text Available Sliding hernias involving the urinary bladder are rare, almost exclusively seen in men. As a result of slipping of the posterior parietal peritoneum on the underlying retroperitoneal structures, the posterior wall of the sac is not formed of the peritoneum alone, but by a portion of the bladder on either side. This case report presents the case of a 54 year old male patient with Right groin swelling since two years, gradually increasing in size with complaints of pain at the site of the swelling prior to voiding and also, an increase in the size of the swelling on retaining urine for a long duration. Based on clinical and radiological findings patient was diagnosed with Sliding inguinal hernia with bladder component, and underwent Open suture less 3D Mesh repair, with replacement of the bladder in the retroperitoneal space. The aim of this case report is to highlight the successful surgical management of a rare sliding hernia involving the urinary bladder using suture less 3D mesh repair. [Int J Res Med Sci 2016; 4(7.000: 3068-3070

  3. Postoperative recovery after mandibular third molar surgery: a criteria for selection of type of surgical site closure.

    Science.gov (United States)

    Damodar, Neeliahgari Durga Akhila; Nandakumar, Hanumanthaiah; Srinath, Narashimha Murthy

    2013-01-01

    This study sought to evaluate postoperative recovery after mandibular third molar surgery, with and without the use of sutures. This study utilized 50 healthy subjects (19 females and 31 males, 18-40 years of age) with bilateral impacted third molars. Two impacted teeth were removed from each patient (60 min maximum operating time). For each patient, the surgical site on one side of the mouth was closed for primary healing by using nonresorbable sutures, while the surgical site on the other side of the mouth was left open for secondary healing. Postoperative recovery was assessed by determining pain (using a visual analog scale) and swelling (by measuring anatomical landmarks pre- and postoperatively on Days 2, 5, and 7) Any incidence of socket infection and hemorrhage were considered to be complications. Both statistical analysis and clinical observation showed that the surgical sites with nonresorbable sutures showed greater swelling and a higher intensity of pain than the surgical sites without sutures; however, there were no statistical or clinical differences in pain and swelling postsurgery at Day 7. The results suggest secondary closure (that is, without sutures) after third molar surgery will produce less postoperative discomfort than primary closure (with nonresorbable sutures).

  4. All-inside arthroscopic suturing technique for meniscal ruptures.

    Science.gov (United States)

    Darabos, Nikica; Dovzak-Bajs, Ivana; Bilić, Vide; Darabos, Anela; Popović, Iva; Cengić, Tomislav

    2012-03-01

    The most frequent indication for surgical treatment of the knee is lesion of the meniscus. The "all inside" arthroscopic technique with bioresorptive material for meniscus lesion is becoming the most popular treatment. This prospective study included 10 patients with posterior meniscal horn lesion operatively treated at Sports Traumatology Department. The "all inside" technique was performed by intra-articular application of bioresorptive pins-Darts sticks or Meniscus Viper and bioresorptive string. Patients were followed up for 2-6 months postoperatively and graded according to the IKDC 2000 scale. All surgical treatments showed satisfactory results. Young patients with acute longitudinal peripheral lesion-posterior horn lesions, in the red-red or red-white meniscal zone, 1-2 centimeters long are most appropriate for this type of treatment. In these patients, this technique proved to be superior and free from the risk of neurovascular damage. For better authentication of this conclusion, additional prospective randomized studies should be performed.

  5. Identification and quantification of the crystalline structures of poly(vinylidene fluoride) sutures by wide-angle X-ray scattering and differential scanning calorimetry.

    Science.gov (United States)

    Laroche, G; Lafrance, C P; Prud'homme, R E; Guidoin, R

    1998-02-01

    The outstanding biocompatibility of the polyvinylidene fluoride (PVDF) monofilament suture together with other desirable characteristics, such as ease of handling and resistance to biodegradation, makes it an attractive alternative monofilament suture material for cardiovascular surgery. However, to achieve a high performance suture, the polymeric raw material must be exposed to different treatments, which lead to different degrees and types of crystallization. Since these crystalline modifications deeply influence the mechanical characteristics and the biostability of the sutures, the authors hereby propose a method of quantifying the different structures of PVDF using wide angle X-ray diffraction (WAXD) and differential scanning calorimetry (DSC). The commercial devices are achieved by coloring and processing the polymeric raw material. The white and unprocessed 4-0 unswaged suture presents 19% of the alpha phase, 38% of the beta structure, and no gamma form. Coloration increases the amount of the beta phase by 5-9% at the expense of the alpha phase. On the other hand, processing the fibers lead to the conversion of some of the amorphous phase to the gamma structure, the importance of which is 6-7%. Finally, tensile measurements performed on the different PVDF fibers clearly proves that their mechanical characteristics depend on the presence of these crystalline forms in the polymeric structure of PVDF.

  6. Assessment of mechanical properties and dimensions of suture threads utilized in orthopedic surgeries

    Directory of Open Access Journals (Sweden)

    Sardenberg Trajano

    2003-01-01

    Full Text Available Surgical materials of monofilament nylon (0, 3-0 and 4-0, braided polyester (0, 3-0 and 4-0 and monofilament polypropylene (0, 3-0 and 4-0 of 7 trademarks commercialized in Brazil, was submitted to analysis of diameter, length, enchasement resistance, tensile strength of surgery materials knotted and unknotted, according to ABNT. The results show that most of surgical materials was inside of preconizing patterns of ABNT.

  7. Prosthetic mesh "slim-cigarette like" for laparoscopic repair of ventral hernias: a new technique without transabdominal fixation sutures.

    Science.gov (United States)

    Canton, S A; Merigliano, S; Pasquali, C

    2016-06-01

    Prosthetic mesh rolled up and fixed with stitches like a slim cigarette ("slim-mesh") for laparoscopic ventral hernia (VH) repair is an new technique which allows an easy intraperitoneally introduction, distension and circumferential fixation of a prosthetic mesh without transabdominal fixation sutures even for meshes larger than 16 cm up to 30 cm for the "slim-mesh" repair of wide ventral hernias. We report the technique of laparoscopic repair of VH with "slim-mesh". This technique enables an easy intra-peritoneally introduction of the mesh through the trocar because it reduces consistently its size, it allows a rapid intra-abdominal handling of the mesh and a fast and easy fixation for VH repair. The average time of surgery with "slim-mesh" for treatment of all 28 VH was 97 min ranging from 57 to 160 min. The average time for the repair of the 24 VH smaller than 10 cm was 91 and 135 min for the four VH larger than 10-22 cm. This new surgical technique leads to a reduction of surgical risks avoiding the use of transfascial sutures with the associated complications. This new surgical procedure in our experience is fast, safe, simple and also easily reproducible by surgeons in laparoscopic training. This technique may be used in wide VH (larger than 10-22 cm) that generally require open surgery.

  8. Failure strength of repair devices versus meniscus suturing techniques.

    Science.gov (United States)

    Aşík, Mehmet; Sener, Nadir

    2002-01-01

    The purpose of this study was to compare the load to failure of different common suturing techniques with repair devices. Seventy-one calf medial menisci were cut to simulate peripheral longitudinal tears and repaired with one of 13 repair techniques. The two parts of the meniscus were pulled using the Instron tensometer until failure occurred. The techniques and repair devices tested were vertical (0 PDS, 2-0 PDS, 2-0 Ethibond), horizontal (0 PDS, 2-0 PDS, 2-0 Ethibond) suturing, T-fix, Mitek, Clearfix screw, Clearfix dart, Biostinger, S-D-sorb, and Artrex dart. The strongest repair method in our study was the vertical sutures with 0 PDS. In this study the mean failure strength of all meniscal repair devices was lower than that of the vertical and horizontal suturing techniques. All meniscus repair devices except T-fix and in some the Arthrex dart (40% broken up) pulled out of the menisci. Devices which had only horizontally placed barbs had lower mean failure strength. Failure strength of T-fix was similar to horizontal sutures with 2-0 Ethibond and 2-0 PDS. In conclusion, because all meniscal repair devices had inferior results, when such devices are used, postoperative rehabilitation should not be hastened, and their inferior primary stability should be kept in mind.

  9. Alar Suspension Sutures in the Management of Nasal Valve Collapse.

    Science.gov (United States)

    Manickavasagam, Jaiganesh; Iqbal, Isma; Wong, Smeeta; Raghavan, Ullas

    2015-09-01

    This study assesses the efficacy of alar suspension sutures in the management of nasal valve collapse causing nasal obstruction. These sutures are inserted between the vestibular skin and lateral crura and hitched to the periosteum of the medial inferior orbital margin; this is a variation of the alar (change everywhere) suspension suture technique. A retrospective review of patients who underwent alar suspension suture insertion between January 2009 and December 2010 in the management of nasal obstruction was undertaken. Symptoms of nasal obstruction were assessed using the Visual Analogue Scale (VAS) and peak inspiratory flow rate (PIFR). This was measured preprocedure and repeated at 3, 6, and 12 months postoperatively. A total of 35 patients were identified, and 26 were included in the study; 90% of patients were satisfied with the outcome of surgery, supported by improvement in the VAS and PIFR scores. The mean difference in VAS preprocedure and postprocedure was 4.97 (P value = 0.00), and the average improvement in PIFR was 25.5 L/min (P value = 0.00). Our study shows a significant improvement in patient's symptoms following insertion of alar suspension sutures. It is, therefore, a reliable, safe, and effective technique in treating nasal obstruction secondary to nasal valve collapse. © The Author(s) 2015.

  10. Quantitative evaluation of midpalatal suture maturation via fractal analysis

    Science.gov (United States)

    Kwak, Kyoung Ho; Kim, Yong-Il; Kim, Yong-Deok

    2016-01-01

    Objective The purpose of this study was to determine whether the results of fractal analysis can be used as criteria for midpalatal suture maturation evaluation. Methods The study included 131 subjects aged over 18 years of age (range 18.1–53.4 years) who underwent cone-beam computed tomography. Skeletonized images of the midpalatal suture were obtained via image processing software and used to calculate fractal dimensions. Correlations between maturation stage and fractal dimensions were calculated using Spearman's correlation coefficient. Optimal fractal dimension cut-off values were determined using a receiver operating characteristic curve. Results The distribution of maturation stages of the midpalatal suture according to the cervical vertebrae maturation index was highly variable, and there was a strong negative correlation between maturation stage and fractal dimension (−0.623, p Fractal dimension was a statistically significant indicator of dichotomous results with regard to maturation stage (area under curve = 0.794, p fractal dimension was used to predict the resulting variable that splits maturation stages into ABC and D or E yielded an optimal fractal dimension cut-off value of 1.0235. Conclusions There was a strong negative correlation between fractal dimension and midpalatal suture maturation. Fractal analysis is an objective quantitative method, and therefore we suggest that it may be useful for the evaluation of midpalatal suture maturation. PMID:27668195

  11. Suture-Button Reconstruction of the Interosseous Membrane.

    Science.gov (United States)

    Meals, Clifton G; Forthman, Christopher L; Segalman, Keith A

    2016-08-01

    Reconstruction of the interosseous membrane (IOM) may play a role in the treatment of acute and chronic longitudinal forearm instability. Several reconstruction techniques have been proposed. Suture-button reconstruction is attractive because it obviates donor site morbidity and is relatively easy to perform. How this method compares to its alternatives, however, is unknown. We review literature describing reconstruction of the forearm axis. We describe how we perform suture-button reconstruction of the IOM, summarize our previously published biomechanical data on the subject, and offer a case report. A suture-button is implanted so as to approximate the course of the interosseous ligament. This may be accomplished percutaneously, or when grafting is desired, through an open approach. Data informing the choice of one reconstruction technique over another consist mostly of biomechanical studies and a small number of case reports. Suture-button reconstruction of the IOM may encourage anatomic healing of acute forearm axis injuries especially as an adjunct to radial head replacement or repair. Chronic injuries may benefit from a combination suture-button graft construct and ulnar shortening osteotomy.

  12. Current Status of Open Surgical Treatment Protocols for Subacromial Impingement Syndrome Associated with Rotator Tear

    Directory of Open Access Journals (Sweden)

    Oktay Gazi

    2012-06-01

    Full Text Available Objective: The aim of this study was to evaluate the recent treatment protocols for Neer stage III subacromial impingement syndrome with open anterior acromioplasty and rotator cuff repair. Material and Methods: Twenty-two patients (8 males, 14 females; mean age: 52.9±10.2 who were diagnosed with a rotator cuff tear based on clinical and radiological findings between 2009 and 2010 participated in the study.. We used the open surgical decompression technique which was previously described by Neer. The ruptured tendon ends were isolated and were fixed to the bones with appropriate suture anchors and transosseoz sutures. Preoperative, postoperative and the final follow-up Constant and UCLA shoulder scores were evaluated. Results: The mean preoperative Constant score was 34.4±6.6 and UCLA score was 13.8±3.3. The mean postoperative Constant score was 73±7.6 and UCLA score was 31.7±3.3. Significant improvement was observed in postoperative shoulder scores (p<0.01 and postoperative shoulder range of motion in all patients (p<0.01. Conclusion: Currently, clinical and functional results of open and arthroscopic subacromial rotator cuff decompression are similar. However, many surgeons prefer the open method and achieve successful results. (The Me di cal Bul le tin of Ha se ki 2012; 50: 59-63

  13. Structural brain differences in school-age children with and without single-suture craniosynostosis.

    Science.gov (United States)

    Aldridge, Kristina; Collett, Brent R; Wallace, Erin R; Birgfeld, Craig; Austin, Jordan R; Yeh, Regina; Feil, Madison; Kapp-Simon, Kathleen A; Aylward, Elizabeth H; Cunningham, Michael L; Speltz, Matthew L

    2017-04-01

    OBJECTIVE Single-suture craniosynostosis (SSC), the premature fusion of a cranial suture, is characterized by dysmorphology of the craniofacial skeleton. Evidence to suggest that children with SSC are at an elevated risk of mild to moderate developmental delays and neurocognitive deficits is mounting, but the associations among premature suture fusion, neuroanatomy, and neurocognition are unexplained. The goals of this study were to determine 1) whether differences in the brain are present in young children with the 2 most common forms of SSC (sagittal and metopic) several years following surgical correction, and 2) whether the pattern of differences varies by affected suture (sagittal or metopic). Examination of differences in the brains of children with SSC several years after surgery may illuminate the growth trajectory of the brain after the potential constraint of the dysmorphic cranium has been relieved. METHODS The authors compared quantitative measures of the brain acquired from MR images obtained from children with sagittal or metopic craniosynostosis (n = 36) at 7 years of age to those obtained from a group of unaffected controls (n = 27) at the same age. The authors measured the volumes of the whole brain, cerebral cortex, cerebral white matter, cerebral cortex by lobe, and ventricles. Additionally, they measured the midsagittal area of the corpus callosum and its segments and of the cerebellar vermis and its component lobules. Measurements obtained from children with SSC and controls were compared using linear regression models. RESULTS No volume measures of the cerebrum or of the whole brain differed significantly between patients with SSC and controls (p > 0.05). However, ventricle volume was significantly increased in patients with SSC (p = 0.001), particularly in those with sagittal craniosynostosis (p brain size or regional differences in the size of the lobes of the cerebrum in children with metopic and sagittal synostosis suggests that the

  14. Intercostal thoracotomy closure: transcostal sutures as a less painful alternative to circumcostal suture placement.

    Science.gov (United States)

    Rooney, Matthew B; Mehl, Margo; Monnet, Eric

    2004-01-01

    To determine if transcostal thoracotomy closure resulted in less pain than circumcostal closure. Experimental cadaver and prospective clinical study. Two canine cadavers and 13 adult, 22-29 kg dogs. Phase 1: In 2 cadavers, 4 suture passage techniques were evaluated to determine the incidence of nerve entrapment in circumcostal intercostal thoracotomy closure. Phase 2: Pain after circumcostal closure (7 dogs) or transcostal closure (6 dogs) of a 4th intercostal space thoracotomy was evaluated by use of pain threshold scores, fentanyl administration rates, heart and respiratory rates, and numerical ratings for behavior. Arterial blood gas analyses were obtained 4 hours postoperatively. Transcostal closure was accomplished by drilling 5-6 small holes in the 5th rib and passing sutures through the holes and around the 4th rib to achieve closure. Pain threshold scores (PTS) were measured by an observer unaware of closure assignment, at 2, 4, 12, and 24 hours after closure by applying slowly increasing pressure to the incision line using a load cell. Rates of fentanyl administration were adjusted based on subjective impressions of dog comfort by a second observer unaware of closure assignment. A 70-100% incidence of nerve entrapment was found for all circumcostal techniques. PTS was higher (P=.045) and fentanyl infusion rates were lower (P=.001) for the transcostal group at 2, 4, 12, and 24 hour postoperatively compared with the circumcostal group. There is a high incidence of nerve entrapment using circumcostal closure techniques. A transcostal technique appears to be associated with less pain during the first 24 hours postoperatively. Based on lower pain scores, transcostal thoracotomy closure may be preferable to circumcostal closure techniques.

  15. An in vitro study assessing the effect of mesh morphology and suture fixation on bacterial adherence.

    Science.gov (United States)

    Sanders, D; Lambie, J; Bond, P; Moate, R; Steer, J A

    2013-12-01

    Prosthetic infections, although relatively uncommon in hernia surgery, are a source of considerable morbidity and cost. The aims of this experimental study were to assess the influence of the morphological properties of the mesh on bacterial adherence in vitro. The morphological properties assessed were the polymer type, filament type, filament diameter, mesh weight, mean pore size, and the addition of silver chlorhexidine and titanium coatings. In addition, the study assessed the effect on bacterial adherence of adding a commonly used suture to the mesh and compared adherence rates to self-gripping mesh that does not require suture fixation. Eight commercially sourced flat hernia meshes with different material characteristics were included in the study. These were Prolene(®) (Ethicon(®)), DualMesh(®) (Gore(®)), DualMesh(®) Plus (Gore(®)), Parietex™ ProGrip (Covidien™), TiMesh(®) Light (GfE Medical), Bard(®) Soft Mesh (Bard(®)), Vypro(®) (Ethicon(®)), and Omyra(®) (Braun(®)). Individual meshes were inoculated with Staphylococcus epidermidis and Staphylococcus aureus with a bacterial inoculum of 10(2) bacteria. To assess the effect of suture material on bacterial adhesion, a sterile piece of commonly used monofilament suture material (2.0 Prolene(®), ZB370 Ethicon(®)) was sutured to selected meshes (chosen to represent different commonly used polymers and/or the presence of an antibacterial coating). Inoculated meshes were incubated for 18 h in tryptone soy broth and then analysed using scanning electron microscopy. A previously validated method for enumeration of bacteria using automated stage movement electron microscopy was used for direct bacterial counting. The final fraction of the bacteria adherent to the mesh was compared between the meshes and for each morphological variable. One-way analysis of variance (ANOVA) was performed on the bacterial counts. Tukey's test was used to determine the difference between the different biomaterials in

  16. Unidirectional barbed suture versus standard monofilament for urethrovesical anastomosis during robotic assisted laparoscopic radical prostatectomy

    Directory of Open Access Journals (Sweden)

    Marc Manganiello

    2012-02-01

    Full Text Available PURPOSE: V-LocTM180 (Covidien Healthcare, Mansfield, MA is a new unidirectional barbed suture that may reduce loss of tension during a running closure. We evaluated the use of the barbed suture for urethrovesical anastomosis (UVA during robotic assisted laparoscopic prostatectomy (RALP. Time to completion of UVA, post-operative anastomotic leak rate, and urinary incontinence were compared in patients undergoing UVA with 3-0 unidirectional-barbed suture vs. 3-0 MonocrylTM (Ethicon, Somerville, NJ. MATERIALS AND METHODS: Data were prospectively collected for 70 consecutive patients undergoing RALP for prostate cancer between November 2009 and October 2010. In the first 35 patients, the UVA was performed using a modified running van Velthoven anastomosis technique using two separate 3-0 monofilament sutures. In the subsequent 35 patients, the UVA was performed using two running novel unidirectional barbed sutures. At 7-12 days postoperatively, all patients were evaluated with a cystogram to determine anastomotic integrity. Urinary incontinence was assessed at two months and five months by total daily pad usage. Clinical symptoms suggestive of bladder neck contracture were elicited. RESULTS: Age, PSA, Gleason score, prostate size, estimated blood loss, body mass index, and clinical and pathologic stage between the 2 groups were similar. Comparing the monofilament group and V-LocTM180 cohorts, average time to complete the anastomosis was similar (27.4 vs. 26.4 minutes, p = 0.73 as was the rate of urinary extravasation on cystogram (5.7 % vs. 8.6%, p = 0.65. There were no symptomatic bladder neck contractures noted at 5 months of follow-up. At 2 months, the percentage of patients using 2 or more pads per day was lower in the V-LocTM180 cohort (24% vs. 44%, p < 0.02. At 5 months, this difference was no longer evident. CONCLUSIONS: Time to complete the UVA was similar in the intervention and control groups. Rates of urine leak were also comparable

  17. The effects of magnetic resonance imaging on surgical staples: an experimental analysis.

    Science.gov (United States)

    Gayton, J Christopher; Sensiba, Paul; Imbrogno, Brian F; Venkatarayappa, Indresh; Tsatalis, James; Prayson, Michael J

    2011-05-01

    Surgical staples are commonplace in repairing surgical incisions. Staples allow for expeditious closure and removal compared with suture materials. However, there are clinical concerns when obtaining a magnetic resonance imaging (MRI) scan with staples present. This study examined two issues related to MRI scanning in the presence of surgical staples: skin surface temperature change and staple displacement. Thirty pig feet had 3-cm surgical incisions repaired with five surgical staples. Once placed, each skin staple position was marked for later referencing. A surface temperature laser device recorded prescan skin surface temperature. A 35-minute MRI scan was performed with a 1.5-Tesla magnet and standard knee coil for each pig foot. Immediately afterward, the skin surface temperature and displacement measurements were recorded. The paired t test was used to analyze temperature change from prescan to postscan. The prescan mean temperature was 16.45°C (standard deviation: 0.70°C), and the range was 14.60°C to 18.20°C. After scanning, the mean temperature was 16.02°C (standard deviation: 0.63°C), and the range was 15.00°C to 17.60°C. The decrease of 0.43°C in skin surface temperature was statistically significant (p=0.001). No change in staple position was measurable or evident by visual inspection for any of the pig feet. This study found no increase in skin surface temperature or displacement of staple position after a standard extremity MRI scan. Based on our findings, MRI scanning in the presence of stainless steel surgical staples seems safe.

  18. Guitar-String Suture to Facilitate Closure of a Finger-like Flap for Reconstruction of the Nose.

    Science.gov (United States)

    Querol-Cisneros, E; Redondo, P

    2017-09-01

    The basic principle of a lobed or finger-like transposition flap is that, after covering the defect with the transposed tissue, the donor site is closed primarily. With large defects, a second lobe may be added to the flap if primary closure of the area left by the first lobe is not possible. The flap can often be made to adapt to the defect, but this maneuver, in combination with primary closure of the adjacent tissue, can sometimes produce excessive tension and compromise the blood supply. We present a series of 4 patients with epithelial tumors of the lateral wall of the nose. The defects left by surgical excision were covered by finger-like transposition flaps. Subcutaneous sutures called guitar-string sutures were used to reduce the size of the defect and facilitate tension-free closure. We propose use of the guitar-string subcutaneous suture in those cases in which the defect is larger than the area that can be covered by the flap. This will make it easier to adapt the flap to the defect and will reduce the risk of excessive tension causing necrosis of the transposed tissue. Copyright © 2017. Publicado por Elsevier España, S.L.U.

  19. New technical procedure involving Achilles tendon rupture treatment through transcutaneous suture.

    Science.gov (United States)

    TarniŢă, DănuŢ Nicolae; TarniŢă, Daniela; Grecu, Dan Cristian; Calafeteanu, Dan Marian; Căpitănescu, Bogdan

    2016-01-01

    The Achilles tendon is the widest tendon of the human body. Achilles tendon belongs to the extrasynovial tendons group and this allows it a faster recovery, thanks to local hematoma from the peritenon, necessary for the scarification. We concluded that in Achilles tendon rupture treatment it is essential to maintain the tendon covering skin integrity, the peritendinous integrity, to maintain the local hematoma formed during and after tendon rupture, reattaching the ruptured tendon heads and maintain them in this position by suturing them and by relaxing the sural triceps muscle. The percutaneous suture requires five pairs of mirror micro-incisions (5 mm) on one side and the other of the tendon. It is necessary for one of the pairs to be placed to the rupture level. With a surgical needle, we arm the proximal and distal heads of the tendon by different threads. By traction and muscular relaxation, we bring in contact the two ruptured heads and then we knot together the arming threads. The inferior member was cast immobilized in relaxing position for the sural triceps muscle for a 45 days period. Using this technique, we have operated 15 cases in our Clinic. In all the cases, we obtained a healing by first intention of the tegument micro-incisions. After the cast immobilization suppression, during 30 days the patients were in a recovery program. At the end of this program, they have recovered completely the dorsal and plantar flexion and the walking. In four months after the surgery, the esthetic of the area is completely restored, this technique being the only surgical technique that realizes this recovery.

  20. Intracardiac ultrasonic suture welding for knotless mitral valve replacement.

    Science.gov (United States)

    Ruel, Marc; Streeter, Richard B; de la Torre, Ralph; Liddicoat, John R; Cohn, William E

    2002-02-01

    The difficulty in tying multiple knots with endoscopic instruments constitutes a technical obstacle to the development of closed-chest valve surgery. The following set of experiments was undertaken to ascertain the in-vivo feasibility of using an intracardiac ultrasonic welding device for knotless suture fixation during mitral valve replacement (MVR). Five adult sheep weighing 48-52 kg underwent MVR with a commercially available mechanical prosthesis, using pledgetted interrupted polypropylene sutures. An ultrasonic suture welder designed for intracardiac use was used to adjust suture tension and fuse strands together without knots. Echocardiographic assessment of the mitral prosthesis was carried out at baseline and after maintenance of supraphysiologic arterial pressures for 60 min. Subsequently, the animals' explanted hearts were assessed under sustained left ventricular (LV) pressurization to 180 mmHg in an ex-vivo pressure-loop system. MVR was successfully performed in all animals and welds reliably completed in less than 1 s. One sheep could not successfully be weaned off cardiopulmonary bypass; however, a normal prosthetic valve implant was confirmed at post-mortem examination. Echocardiographic assessment prior to and during LV pressurization revealed normal seating and function of the prosthesis in all cases. At post-mortem examination all valves were adequately implanted, suture tails laid flat on the surface of the prosthesis' sewing ring, welded suture strands were intact and accurately point-fused together, and no evidence of perivalvular leak was found around any of the prostheses despite sustained LV pressurization. This new modality proved reliable in an acute sheep model of MVR and could constitute a promising avenue towards facilitation of total endoscopic valve procedures in humans.

  1. Preliminary results from 28 cases of pilonidal cyst treated by excision and primary closure of the wound, reinforced with support suturing

    Directory of Open Access Journals (Sweden)

    Nelson de Souza Liboni

    2007-06-01

    Full Text Available Objectives: To describe the results of the surgical technique of pilonidalcyst excision with margins and primary closure of the operative woundwith support suturing. Methods: Twenty-eight patients with pilonidaldisease admitted to a private clinic between 1999 and 2006 underwentsurgical treatment by means of an elliptical longitudinal medial incisionproportional to the palpable tumor size and excision of cyst with 2-cmmargins above, below and laterally, and primary closure of the wound.To reduce the tension in the operative wound, suturing was performed,with a single support stitch of horizontal U-shape. The patients werefollowed up for periods ranging from 6 months to 3 years. Results:Two patients developed abscesses at the surgical site (7.1%, andone required complete opening of the operative wound for drainage.Both underwent excision and primary closure again. The pathologicalexamination demonstrated that these were not cases of relapse, butof recurrent abscess. No cases of non-infected collection (seroma andhematoma, spontaneous dehiscence of the operative wound or diseaserecurrence were recorded. Conclusions: The technique of pilonidal cystexcision with margins and primary closure of the wound reinforcedwith support suturing seems to be attractive, since it is characterizedby low complexity and low infection rate. Studies with larger samplesare needed to validate this surgical technique.

  2. Power scaling of ammonitic suture patterns from the suborder Ancyloceratina

    Science.gov (United States)

    Peterman, D. J.; Barton, C. C.

    2016-12-01

    The spatial scaling of suture patterns from 44 ammonite species of the suborder Ancyloceratina was measured using the fractal box counting method. These specimens were selected from every stage in the Cretaceous and range between approximately 145 Ma to 66 Ma in age. The sutures analyzed in this study were found from published literature where half of the three dimensional paths along the last septal margins were projected on a two dimensional surface. The fractal dimension calculated from the suture patterns ranges from 1.23 to 1.58. These values positively correlate to whorl height (the length between the venter and umbilicus through a transverse cross-section at the last septum of an adult specimen) with a least squares regression analysis correlation coefficient r = 0.617. The fractal dimensions of Cretaceous sutures from Ancyloceratina were compared to a study by Olóriz et al. (2002) where fractal dimensions were measured for suture patterns of 280 species of Late Jurassic ammonites. They found a significant positive correlation (r = 0.500) between fractal dimension and whorl height but only for neritic species (ammonites that inhabit the shallow domain before the drop off of the continental shelf), and a less significant relationship (r = 0.148) for epioceanic species (that occupy the zone beyond the drop off of the continental shelf). Of the 44 sutures from Ancyloceratina analyzed in our study, 41 are presumed to inhabit the epioceanic domain, yet they still exhibit a significant positive relationship (r = 0.617) between fractal dimension and whorl height. This means that this correlation is not restricted to neritic ammonites and may be a function of shell size as proxied by whorl height. There is some inconsistency between these two studies including the vastly different heteromorphic shell forms of Ancyloceratina (with many non-planispiral forms) and temporal variation. Nevertheless, our results provide insight on the role of corrugated septal margins

  3. 4. Suture-less bio-prosthetic aortic valve replacement: Early clinical and hemodynamic outcome

    Directory of Open Access Journals (Sweden)

    A. Arifi

    2016-07-01

    Full Text Available Suture-less bio-prostheses (SBP are a recent addition in the surgical armamentarium in the surgical treatment of sever aortic valve disease that offer rapid deployment, shorter bypass & ischemic times and excellent hemodynamic performance even in small aortic annulus. We present our initial experience and short-term clinical and hemodynamic results with the use of suture-less bio-prostheses. Between May 2011 and August 2015, 61 patients, with mean age of 72.6 years and severe aortic stenosis underwent aortic valve replacement with a SBP. 28 were males and 19 were females. Mean euroSCORE was 11.5. 55% had coronary artery disease, 8.5% had severe mitral regurgitation and 6.4% had severe tricuspid regurgitation. Left ventricular dysfunction was present in 28% patients and 83% had elevated right ventricular systolic pressure. Average size of aortic annulus was 21.7 mm. 42.5% patients underwent isolated aortic valve replacement while 57.5% had concomitant procedures including coronary artery bypass grafting (25 patients. Average cross clamp time in isolated aortic valve replacement was 34 min and total bypass time was 46 min. Mean gradient across the prostheses was an average of 8.9 mmHg intra-operatively with 4.3% prevalence of mild para-prosthetic leak and 10.6% prevalence of mild prosthetic regurgitation. In-hospital mortality was 2.1% (1 patient. At follow-up, average mean trans-aortic gradients were 15 mmHg and prevalence of mild prosthetic and para-prosthetic leak was 10.5%. Average left ventricular diastolic dimensions changed from 4.93 mm pre-operatively to 4.42 mm post-operatively (p = 0.023 and left ventricular systolic dimensions changed from 3.39 mm pre-operatively to 3.05 mm post-operatively (p = 0.124. Use of suture-less bio-prosthesis for aortic valve replacement produces excellent hemodynamic results with low incidence of para-prosthetic leakage and prosthetic regurgitation. Persistent low trans-aortic gradients and

  4. Avaliação dos resultados do tratamento cirúrgico artroscópico da instabilidade anterior traumática do ombro com sutura da lesão na margem cruentizada da cavidade glenoidal Evaluation of the results from arthroscopic surgical treatment for traumatic anterior shoulder instability using suturing of the lesion at the opened margin of the glenoid cavity

    Directory of Open Access Journals (Sweden)

    Alberto Naoki Miyazaki

    2012-01-01

    Full Text Available OBJETIVO: Avaliar os resultados clínicos dos pacientes portadores de instabilidade anterior traumática do ombro tratados cirurgicamente por visualização artroscópica, utilizando âncoras bioabsorvíveis e com o uso da técnica de cruentização da margem anterior da cavidade glenoidal para a reparação da lesão de Bankart. MÉTODO: Entre março de 2006 e outubro de 2008 foram operados 27 ombros de 27 pacientes com diagnóstico de instabilidade anterior traumática do ombro, com média de idade de 28 anos e número de luxações prévias variando entre dois e 25 episódios. O sexo masculino predominou com 24 (89% pacientes. O tempo mínimo de seguimento foi de 24 meses, com uma média de 36 meses, e nenhum paciente tinha cirurgia prévia no ombro acometido ou lesão óssea significativa na margem glenoidal. A avaliação clínica pós-operatória foi realizada por meio da escala de Rowe. Para medirmos o grau de amplitude articular pré-operatória e pós-operatória, utilizamos o método descrito pela Academia Americana de Cirurgiões Ortopédicos (AAOS. RESULTADO: Pelos critérios de Rowe, 25 pacientes (93% obtiveram resultados excelentes e dois (7% resultados ruins, nenhum paciente apresentou resultado bom ou regular. Vinte e três pacientes estavam satisfeitos com o resultado obtido (85%, retornando às suas atividades sem limitações, e quatro pacientes (15% tinham algum grau de limitação. Houve recidiva da instabilidade em dois pacientes (7%. CONCLUSÃO: O tratamento da instabilidade traumática anterior do ombro por visualização artroscópica com a técnica de cruentização da margem articular anterior da cavidade glenoidal, para reparação da lesão de Bankart, proporcionou excelentes resultados em 93% dos pacientes operados.OBJECTIVE: To evaluate the clinical results from patients with traumatic anterior shoulder instability that was treated surgically through arthroscopic viewing, using bioabsorbable anchors and a technique

  5. Surgical Navigation

    DEFF Research Database (Denmark)

    Azarmehr, Iman; Stokbro, Kasper; Bell, R. Bryan

    2017-01-01

    were identified in the field of traumatology. Treatment of complex orbital fractures was considerably improved by the use of SN compared with traditionally treated control groups. Conclusions: SN seems to be a very promising addition to the surgical toolkit. Planning details of the surgical procedure...... in a 3-dimensional virtual environment and execution with real-time guidance can significantly improve precision. Among factors to be considered are the financial investments necessary and the learning curve....

  6. Observation of artificial lens implantation suture fixation into capsular bag when cataract suspensory ligament rupture without capsular tension ring

    Directory of Open Access Journals (Sweden)

    Yue-Ming Sun

    2017-09-01

    Full Text Available AIM: To explore the cataract suspensory ligament rupture and artificial lens implantation suture fixation into capsular bag without capsular tension ring(CTR.METHODS: We reviewed 20 cases of 20 cataract suspensory ligament rupture without CTR intraocular lens(IOLimplantation fixation in our department from Jan.2012 to Dec.2016. The needle crossed into ocular ciliary sulcus, in the equator of the eye ball which suspensory ligament rupture from, then the needle crossed out 1.5mm away from the angle of sclera. Sutures fixed on the IOL, then the artificial lens implantation in the pouch, carried out in accordance with the “Z” type suture, or to the beforehand prepared triangle scleral flap. The visual acuity, intraocular pressure, the anterior chamber and the IOL position were measured after operations. RESULTS: All of the postoperative visual acuity improved different level. The postoperative best corrected visual acuity(BCVAwas ≥0.8 in 4 eyes(20%, 0.5-0.6 in 7 eyes(35%, 0.3-0.4 in 8 eyes(40%, 0.1 in 1 eye(5%because of the glaucoma optic atrophy. There were 12 cases with mild corneal endothelium edema, 4 cases exudation membrane in the pupil area, 2 cases hyphema, all of which recovered after treatment. There were 2 eyes with vitreous prolapse in the pupil, 1 case appeared mild IOL center deviation and no special treatment for the vision did not be involved. Followed up for 6mo, displaced stitches or artificial lens shift did not occur. CONCLUSION: Without CTR, the IOL implantation and suture fixation in capsular bag during cataract surgery is a surgical method for basic-level hospitals.

  7. Recognition of surgical skills using hidden Markov models

    Science.gov (United States)

    Speidel, Stefanie; Zentek, Tom; Sudra, Gunther; Gehrig, Tobias; Müller-Stich, Beat Peter; Gutt, Carsten; Dillmann, Rüdiger

    2009-02-01

    Minimally invasive surgery is a highly complex medical discipline and can be regarded as a major breakthrough in surgical technique. A minimally invasive intervention requires enhanced motor skills to deal with difficulties like the complex hand-eye coordination and restricted mobility. To alleviate these constraints we propose to enhance the surgeon's capabilities by providing a context-aware assistance using augmented reality techniques. To recognize and analyze the current situation for context-aware assistance, we need intraoperative sensor data and a model of the intervention. Characteristics of a situation are the performed activity, the used instruments, the surgical objects and the anatomical structures. Important information about the surgical activity can be acquired by recognizing the surgical gesture performed. Surgical gestures in minimally invasive surgery like cutting, knot-tying or suturing are here referred to as surgical skills. We use the motion data from the endoscopic instruments to classify and analyze the performed skill and even use it for skill evaluation in a training scenario. The system uses Hidden Markov Models (HMM) to model and recognize a specific surgical skill like knot-tying or suturing with an average recognition rate of 92%.

  8. Biomechanical Comparison of Modified Suture Bridge Using Rip-Stop versus Traditional Suture Bridge for Rotator Cuff Repair

    Directory of Open Access Journals (Sweden)

    ZiYing Wu

    2016-01-01

    Full Text Available Purpose. To compare the biomechanical properties of 3 suture-bridge techniques for rotator cuff repair. Methods. Twelve pair-matched fresh-frozen shoulder specimens were randomized to 3 groups of different repair types: the medially Knotted Suture Bridge (KSB, the medially Untied Suture Bridge (USB, and the Modified Suture Bridge (MSB. Cyclic loading and load-to-failure test were performed. Parameters of elongation, stiffness, load at failure, and mode of failure were recorded. Results. The MSB technique had the significantly greatest load to failure (515.6±78.0 N, P=0.04 for KSB group; P<0.001 for USB group, stiffness (58.0±10.7 N/mm, P=0.005 for KSB group; P<0.001 for USB group, and lowest elongation (1.49±0.39 mm, P=0.009 for KSB group; P=0.001 for USB group among 3 groups. The KSB repair had significantly higher ultimate load (443.5±65.0 N than USB repair (363.5±52.3 N, P=0.024. However, there was no statistical difference in stiffness and elongation between KSB and USB technique (P=0.396 for stiffness and P=0.242 for elongation, resp.. The failure mode for all specimens was suture pulling through the cuff tendon. Conclusions. Our modified suture bridge technique (MSB may provide enhanced biomechanical properties when compared with medially knotted or knotless repair. Clinical Relevance. Our modified technique may represent a promising alternative in arthroscopic rotator cuff repair.

  9. Half-bow sliding knot: modified suture technique for scleral fixation using the corneoscleral pocket.

    Science.gov (United States)

    Chee, Soon-Phaik

    2011-09-01

    A modified suture technique for precise knot placement in the Hoffman corneoscleral pocket technique of scleral fixation is described. Both loops of the polypropylene suture passing from the intraocular device through the sclera and conjunctiva are retrieved from the pocket. A loop of suture is pulled through 3 suture throws made using the second suture loop, forming a half bow. Centration of the intraocular lens (IOL)-capsular bag is checked. If the suture tension is too tight, the surgeon can easily undo the knot of the half-bow knot by pulling it free and can then retie the sliding knot. When the IOL-capsular bag is centered, the suture loop is cut and the free end removed. The second suture end is retrieved from the pocket, and knot tying is completed without further adjustment to the tension. Posterior pressure on the intraocular device centers it and settles the knot within the sclera at the fixation point.

  10. Suture supported P C IOL in a homocystinuric child.

    Directory of Open Access Journals (Sweden)

    Bhatti S

    1996-01-01

    Full Text Available A homocystinuric child presented with a secondary pupillary block glaucoma due to anteriorly subluxated lens. After removal of the subluxated lens, a suture supported posterior chamber IOL was implanted. Postoperative complication of cerebral venous thrombosis following general anaesthesia was managed with high doses of pyridoxine special diet and drugs.

  11. Automatic Detection of Wild-type Mouse Cranial Sutures

    DEFF Research Database (Denmark)

    Ólafsdóttir, Hildur; Darvann, Tron Andre; Hermann, Nuno V.;

    , automatic detection of the cranial sutures becomes important. We have previously built a craniofacial, wild-type mouse atlas from a set of 10 Micro CT scans using a B-spline-based nonrigid registration method by Rueckert et al. Subsequently, all volumes were registered nonrigidly to the atlas. Using...

  12. Cranial suture biology and dental development: genetic and clinical perspectives.

    Science.gov (United States)

    De Coster, P J; Mortier, G; Marks, L A; Martens, L C

    2007-09-01

    Premature fusion of the calvarial bones at the sutures, or craniosynostosis (CS), is a relatively common birth defect (1:2000-3000) frequently associated with limb deformity. Patients with CS may present oral defects, such as cleft soft palate, hypodontia, hyperdontia, and delayed tooth eruption, but also unusual associations of major dental anomalies such as taurodontism, microdontia, multiple dens invaginatus, and dentin dysplasia. The list of genes that are involved in CS includes those coding for the different fibroblast growth factor receptors and a ligand of ephrin receptors, but also genes encoding transcription factors, such as MSX2 and TWIST. Most of these genes are equally involved in odontogenesis, providing a pausible explanation for clinical associations of CS with dental agenesis or tooth malformations. On the basis of the present knowledge on genes and transcription factors that are involved in craniofacial morphogenesis, and from dental clinics of CS syndromes, the molecular mechanisms that control suture formation and suture closure are expected to play key roles in patterning events and development of teeth. The purpose of this article is to review and merge the recent advances in the field of suture research at the genetic and cellular levels with those of tooth development, and to apply them to the dental clinics of CS syndromes. These new perspectives and future challenges in the field of both dental clinics and molecular genetics, more in particular the identification of possible candidate genes involved in both CS and dental defects, are discussed.

  13. Hyperammonemic encephalopathy due to suture line breakdown after bladder operation.

    Science.gov (United States)

    Boogerd, W; Zoetmulder, F A; Moffie, D

    1990-01-01

    A patient is described with a severe encephalopathy and hyperammonemia in absence of liver dysfunction, attributed to urine absorption into the systemic circulation due to suture line breakdown after bladder dome resection. At autopsy characteristic Alzheimer type II astrocytes were found in the basal ganglia.

  14. Functional influence on sutural bone apposition in the growing rat.

    NARCIS (Netherlands)

    Katsaros, C.; Zissis, A.; Bresin, A.; Kiliaridis, S.

    2006-01-01

    INTRODUCTION: The aim of this study was to quantify the influence of reduced masticatory muscle function on sutural bone apposition in the growing rat. METHODS: Twenty-six growing male albino rats were randomly divided into 2 equal groups; 1 (hard-diet group) received the ordinary diet of hard pelle

  15. MERSILENE (POLYESTER), A NEW SUTURE FOR PENETRATING KERATOPLASTY

    NARCIS (Netherlands)

    RAMSELAAR, JAM; BEEKHUIS, WH; RIJNEVELD, WJ; VANANDEL, MV; DIJK, F; JONGEBLOED, WL

    1992-01-01

    Mersilene (polyester monofilament) seems to be suitable for penetrating keratoplasty because it is strong, shows no degradation by ultraviolet light, is insoluble, so that it can be left in situ, and offers the possibility of regulating postoperative astigmatism by suture adjustment. In 12 patients

  16. Tendon Collagen Crosslinking Offers Potential to Improve Suture Pullout in Rotator Cuff Repair: An Ex Vivo Sheep Study.

    Science.gov (United States)

    Camenzind, Roland S; Wieser, Karl; Fessel, Gion; Meyer, Dominik C; Snedeker, Jess G

    2016-08-01

    The suture-tendon interface is often the weakest link in tendon to bone repair of massive rotator cuff tears. Genipin is a low-toxicity collagen crosslinker derived from the gardenia fruit that has been shown to augment collagen tissue strength and mechanically arrest tendon-tear progression. The purpose of the current study was to evaluate whether genipin crosslinking can sufficiently augment the suture-tendon interface to improve suture pullout strength using simple single-loop sutures and the modified Mason-Allen technique. The study also aimed to assess whether time of genipin treatment is a relevant factor in efficacy. In an ex vivo (cadaveric) sheep rotator cuff tendon model, a total of 142 suture pullout tests were performed on 32 infraspinatus tendons. Each tendon was prepared with three single-loop stitches. Two groups were pretreated by incubation in genipin solution for either 4 hours or 24 hours. Two corresponding control groups were incubated in phosphate buffered saline for the same periods. The same test protocol was applied to tendons using modified Mason-Allen technique stitch patterns. Each suture was loaded to failure on a universal materials testing machine. Suture pullout force, stiffness, and work to failure were calculated from force-displacement data, and then compared among the groups. Median single-loop pullout force on tendons incubated for 24 hours in genipin yielded an approximately 30% increase in maximum pullout force for single-loop stitches with a median of 73 N (range, 56-114 N) compared with 56 N (range, 40-69 N; difference of medians = 17 N; p = 0.028), with corresponding increases in the required work to failure but not stiffness. Genipin treatment for 4 hours showed no added benefit for suture-pullout behavior (46 N, [range, 35-95 N] versus 45 N, [range, 28-63 N]; difference of medians, 1 N; p = 1). No tested genipin crosslinking conditions indicated benefit for tendons grasped using the modified Mason-Allen technique after 4

  17. REACTION OF THE RABBIT CORNEAL ENDOTHELIUM TO NYLON SUTURES - A SEM STUDY

    NARCIS (Netherlands)

    JONGEBLOED, WL; VANDERVEEN, G; KALICHARAN, D; RIJNEVELD, WJ; HOUTMAN, WA; WORST, JGF

    1990-01-01

    Nylon and stainless steel sutures separately placed deeply into rabbit corneas by splitting the stroma for a few millimeters, without closing sutures, remained in the cornea for two, four and six weeks respectively. In contrast to the stainless steel sutures an extensive tissue reaction could be obs

  18. REACTION OF THE RABBIT CORNEAL ENDOTHELIUM TO NYLON SUTURES - A SEM STUDY

    NARCIS (Netherlands)

    JONGEBLOED, WL; VANDERVEEN, G; KALICHARAN, D; RIJNEVELD, WJ; HOUTMAN, WA; WORST, JGF

    1990-01-01

    Nylon and stainless steel sutures separately placed deeply into rabbit corneas by splitting the stroma for a few millimeters, without closing sutures, remained in the cornea for two, four and six weeks respectively. In contrast to the stainless steel sutures an extensive tissue reaction could be

  19. Peculiarities of surgical treatment of gastrointestinal tract combined congenital malformations in newborns

    Directory of Open Access Journals (Sweden)

    М. О. Makarova

    2017-04-01

    Full Text Available Congenital gastrointestinal (GI malformations make up 21–25 % of all congenital anomalies and require surgical correction in the neonatal period. The aim was to analyze the methods of operative treatment of hard composite congenital gastrointestinal malformations in infants. Materials and Methods: There were 13 newborns with gastroschisis, omphalocele and esophageal atresia combined with intestinal atresia, anal atresia and also with congenital heart defects in our study. Results. We have designed new preoperative care strategies for the newborns. All combined GI defects were corrected in one step. In gastroschisis and omphalocele in combination with small intestine atresia we made a plastic of anterior abdominal wall, bowel segment resection and anastomosis end-to-end. In esophageal atresia and atresia of the anus direct esophago-esophagoanastomosis was applied with suturing of tracheoesophageal fistula, also in two patients proctoplasty by Pena 2 was carried out, and in one patient with high anal atresia colostomy was applied, which was closed in the age of 6 months. In case of esophageal atresia combined with small intestine atresia direct esophago-esophagoanastomosis with tracheoesophageal fistula suturing was carried out, and resection of the bowel segment with anastomosis end-to-end was applied. In a patient with a combination of esophageal atresia and duodenal obstruction esophagoplasty and closure of tracheoesophageal fistula with anastomosis by Kimur was made. Preference was given to the combined anesthesia with neuraxial blockade. Postoperative care included prolonged artificial lung ventilation, anesthesia, parenteral nutrition, antibacterial and antifungal medicines. Conclusions. One-step correction of the congenital GI malformations in newborns is effective and it gives opportunity to achieve the best results with a single surgical intervention. Extremely important links of the combined GI defects therapy is timely and balanced

  20. Endoscopic management of common patologies with a new suturing system

    Directory of Open Access Journals (Sweden)

    Fernando González-Panizo-Tamargo

    Full Text Available Background: Overstitch endoscopic suturing system (Apollo Endosurgery. Austin, Texas was created for NOTES procedures. As it demonstrated to be feasible, secure and effective in this field, further studies have evaluated its use in common gastrointestinal disorders in which current therapeutic tools, endoscopic or not, are not efficient or safe enough. Published results are promising. We present our initial experience with this system in the management of pathologies we usually face in our clinical practice. Method: Suturing system was evaluated for: 1. Endoscopic fixation of metallic stent to prevent migration in patients with gastrointestinal non-neoformative pathology. 2. Outlet reduction in patients with weight regain following Roux-en-Y gastric bypass. Results: During a period of 6 months Overstitch endoscopic suturing system was used in 5 patients: For stent fixation in 3 and for outlet reduction in 2. Technical success: Suture was performed in all the patients. Only 1 stitch was lost. Effectiveness: Stent fixation and outlet reduction were achieved in all the patients. However, in 1 patient the final anastomotic size was not close enough. Clinical success: Clinical recovery was achieved in all the patients in whom endoscopic stent fixation was performed. The patient which appropriated outlet closure developed a significant weight loss. The patient in which final size was not close enough did not lose weight. Conclusions: We found Overstitch endoscopic suturing system feasible, safe and effective, as it has been previously described. We encourage the publication of further studies evaluating the real utility of this tool, mostly taking into account that it allows a successful management of usual disorders for which there are not current effective therapies.

  1. Surgical Treatment of Displaced Greater Tuberosity Fractures of the Humerus.

    Science.gov (United States)

    Rouleau, Dominique M; Mutch, Jennifer; Laflamme, Georges-Yves

    2016-01-01

    Greater tuberosity fractures of the humerus can be successfully treated nonsurgically in most patients. However, as little as 3 to 5 mm of superior greater tuberosity displacement may adversely affect rotator cuff biomechanics and lead to subacromial impingement in patients who are active. In these cases, surgical treatment is recommended. Multiple surgical techniques include open and arthroscopic options tailored to fracture morphology, and strategies for repair include the use of suture anchors, transosseous sutures, tension bands, and plates/screws. Three classification systems are commonly used to describe greater tuberosity fractures: the AO, Neer, and morphologic classifications. Several hypotheses have been discussed for the mechanism of greater tuberosity fractures and the deforming forces of the rotator cuff, and the use of advanced imaging is being explored.

  2. Effect of caffeic acid phenethyl ester on bone formation in the expanded inter-premaxillary suture

    Directory of Open Access Journals (Sweden)

    Kazancioglu HO

    2015-12-01

    Full Text Available Hakki Oguz Kazancioglu,1 Sertac Aksakalli,2 Seref Ezirganli,1 Muhammet Birlik,2 Mukaddes Esrefoglu,3 Ahmet Hüseyin Acar1 1Department of Oral and Maxillofacial Surgery, 2Department of Orthodontics, Faculty of Dentistry, 3Department of Histology, Faculty of Medicine, Bezmialem Vakif University, Istanbul, Turkey Background: Narrow maxilla is a common problem in orthodontics and dentofacial orthopedics. To solve this problem, a procedure called rapid maxillary expansion (RME has been used. However, relapse tendency is a major problem of RME. Although relapse tendency is not clearly understood, various treatment procedures and new application has been investigated. The present study aimed to investigate the possible effectiveness of caffeic acid phenethyl ester (CAPE on new bone formation in rat midpalatal suture after RME.Materials and methods: Twenty male Sprague Dawley rats were used in this study. The animals were randomly divided into two groups as control and CAPE group. In CAPE group, CAPE was administered systemically via intraperitoneal injection. RME procedure was performed on all animals. For this purpose, the springs were placed on the maxillary incisors of rats and activated for 5 days. After then, the springs were removed and replaced with short lengths of rectangular retaining wire for consolidation period of 15 days. At the end of the study, histomorphometric analysis was carried out to assess of new bone formation.Results: New bone formation was significantly greater in CAPE group than the control group (P<0.05. CAPE enhances new bone formation in midpalatal suture after RME.Conclusion: These results show that CAPE may decrease the time needed for retention. Keywords: rapid maxillary expansion, bone formation, caffeic acid phenethyl ester, midpalatal suture, histopathology

  3. Simulation-based cutaneous surgical-skill training on a chicken-skin bench model in a medical undergraduate program

    Directory of Open Access Journals (Sweden)

    Rafael Denadai

    2013-01-01

    Full Text Available Background: Because of ethical and medico-legal aspects involved in the training of cutaneous surgical skills on living patients, human cadavers and living animals, it is necessary the search for alternative and effective forms of training simulation. Aims: To propose and describe an alternative methodology for teaching and learning the principles of cutaneous surgery in a medical undergraduate program by using a chicken-skin bench model. Materials and Methods: One instructor for every four students, teaching materials on cutaneous surgical skills, chicken trunks, wings, or thighs, a rigid platform support, needled threads, needle holders, surgical blades with scalpel handles, rat-tooth tweezers, scissors, and marking pens were necessary for training simulation. Results: A proposal for simulation-based training on incision, suture, biopsy, and on reconstruction techniques using a chicken-skin bench model distributed in several sessions and with increasing levels of difficultywas structured. Both feedback and objective evaluations always directed to individual students were also outlined. Conclusion: The teaching of a methodology for the principles of cutaneous surgery using a chicken-skin bench model versatile, portable, easy to assemble, and inexpensive is an alternative and complementary option to the armamentarium of methods based on other bench models described.

  4. Sutura de menisco com implantes absorvíveis Meniscus suture with absorbable implants

    Directory of Open Access Journals (Sweden)

    Arnaldo José Hernandez

    2006-01-01

    Full Text Available Os autores avaliam clinicamente 19 pacientes (19 joelhos - 15 meniscos mediais e 5 laterais submetidos à sutura de menisco, utilizando 2 tipos de implantes absorvíveis (ácido polilático Arrow® e Clear fix®. O estudo compõe-se de 15 homens e 4 mulheres com idades entre 16 e 44 anos, com média de 26,8 anos. O tempo de seguimento médio foi de 24 meses, com mínimo de 18 e máximo de 32 meses. A técnica operatória constituiu-se da sutura de um ou ambos os meniscos (1 caso, via artroscópica com Arrow® em 15 pacientes e Clear fix® em 4. Dos 19 indivíduos, 6 foram submetidos à sutura meniscal isolada, 11 associada à reconstrução do LCA e 2 à reconstrução do LCA com osteotomia valgizante da tíbia. Os resultados foram avaliados segundo exame físico incluindo as manobras de Appley e Mc Murray. A avaliação funcional pré e pós-operatória do joelho foi realizada pela escala de Lysholm modificada. Todos os pacientes tiveram suas manobras meniscais negativadas no pós-operatório. A pontuação média pré-operatória segundo a escala de Lysholm foi de 39,8 subindo para 91,5 no pós-operatório. Os autores concluem que a sutura de menisco, utilizando implantes absorvíveis, tem se mostrado eficiente até o momento, e que tecnicamente ela é mais simples que a sutura convencional.The authors clinically assessed 19 patients (19 knees - 15 medial meniscus and 5 lateral meniscus submitted to meniscus suture using 2 kinds of absorbable implants (polylactic acid Arrow® and Clear fix®. The study is composed of 15 males and 4 females, ages ranging 16 - 44 years old (average = 26.8 years old. The mean follow-up time was 24 months, ranging from 18 to 32 months, at most. The surgical technique was constituted of a suture in one or both meniscus (1 case, through arthroscopy with Arrow® in 15 patients and Clear fix® in 4. From the 19 individuals, 6 were submitted to isolated meniscal suture, 11 combined to ACL reconstruction and 2 to ACL

  5. Surgical preparation of a permanent carotid transposition in sheep

    OpenAIRE

    Gouvêa, Liana Villela de; Novais, Ernane de Paiva Ferreira; Leite, Ceci Ribeiro; Ximenes, Fábio Henrique Bezerra; de Almeida, Ricardo Miyasaka; Molás, Renato Bizinoto; Palermo, João Gabriel Cesar; Silva, Carlos Eduardo Vasconcelos da; Borges,José Renato Junqueira; Lima, Eduardo Maurício Mendes de; Godoy, Roberta Ferro de

    2011-01-01

    In large animal research, when frequent sampling of arterial blood is needed, the carotid artery transposition is the most used technique. The objective of this paper is to describe a new technique for carotid artery transposition in sheep and evaluate its effectiveness using the echo-Doppler ultrasound. The animals enrolled in this study had their carotid surgically elevated to the subcutaneous level, by suturing underneath muscles sternocephalic and brachiocephalic. None of the ...

  6. The 2.5 mm PushLock suture anchor system versus a traditional suture anchor for ulnar collateral ligament injuries of the thumb: a biomechanical study.

    Science.gov (United States)

    Jarrett, C D; McGillivary, G R; Hutton, W C

    2010-02-01

    We compared the biomechanical strength of the 2.5 mm PushLock suture anchor with a traditional Bio-SutureTak suture anchor in repair of ulnar collateral ligament injuries. Iatrogenic ulnar collateral ligament injuries in 18 cadaveric thumbs were repaired and used to test for load to failure and cyclic loading. The average force required to generate a 2 mm gap was 7.7 N for the 2.5 mm PushLock and 6.3 N for the Bio-SutureTak (p = 0.04). The ultimate load to failure was 28.0 N for the 2.5 mm PushLock and 18.8 N for the Bio-SutureTak (p = 0.16). There were no statistical differences between the two suture anchors under cyclic loading. The 2.5 mm PushLock suture anchor provides significantly stronger resistance to 2 mm gap formation at the repair site and is less likely to fail at the suture-ligament interface. However, there was no difference in the load to failure between the two suture anchors.

  7. New developments for the surgical treatment of shoulder problems; Neuentwicklungen in der orthopaedisch-chirurgischen Therapie der Schulter

    Energy Technology Data Exchange (ETDEWEB)

    Anderl, W. [Orthopaedische Abteilung, Krankenhaus der Barmherzigen Schwestern Wien (Austria)

    2004-06-01

    Tremendous advancement has been made in the surgical treatment of the shoulder within the last years. Arthroscopic techniques for treatment of rotator cuff lesions, instability problems and biceps tendon lesions are today established because of significant improvement of instruments, suture materials and anchor techniques. The 4th generation of shoulder prosthesis systems guarantee today anatomical and biomechanical advantages with significant functional improvement for the patient. (orig.) [German] Die Schulterchirurgie hat sich in den letzten Jahren enorm weiterentwickelt. Arthroskopische Techniken zur Behandlung von Rotatorenmanschettenlaesion, Instabilitaet und Bizepssehnenlaesion haben sich durch verbesserte Instrumente, Anker und Nahtmaterialen etabliert. Die 4. Generation anatomischer Schulterprothesen zeigt anatomische und biomechanische Vorteile gegenueber frueheren Prothesensystemen und einen Funktionsgewinn fuer den Patienten. (orig.)

  8. Under the microscope: assessing surgical aptitude of otolaryngology residency applicants.

    Science.gov (United States)

    Carlson, Matthew L; Archibald, David J; Sorom, Abraham J; Moore, Eric J

    2010-06-01

    Application to otolaryngology residency is a highly competitive process. Programs identify the best candidates by evaluating academic performance in medical school, board scores, research experience, performance during an interview, and letters of recommendation. Unfortunately, none of these metrics completely assess an applicant's capacity to learn and perform surgical skills. We describe a direct assessment of an applicant's ability for rapid surgical skill acquisition, manual dexterity, and response to stress that can be performed during the interview process. A retrospective study at an academic otolaryngology residency program. After orientation, applicants were seated at a microsurgical training station and allotted 20 minutes to suture an incision using 10-0 nylon suture on a latex practice card. Their performance was graded using a 1-to-5 scoring system for the following categories: microscope use, respect for tissue, instrument handling, knot tying and suture control, skills acquisition, and attitude toward the exercise. Applicants were given some instruction and assessed on their ability to incorporate what they had learned into their technique. The average total applicant score was 23.2, standard deviation (SD) 3.6 (maximum 30); 13.4% of applicants scored 1 SD above the mean. The value of applicant screening tests in predicting surgical competency is controversial. We describe a direct assessment tool that may prove useful in identifying outliers, both high and low, to aid in final applicant ranking.

  9. Surgical crown lengthening: a 12-month study - radiographic results

    Directory of Open Access Journals (Sweden)

    Daniela Eleutério Diniz

    2007-08-01

    Full Text Available OBJECTIVE: The purpose of this study was to perform a radiographic follow-up evaluation after a 12-month healing period, following crown lengthening surgery. MATERIAL AND METHODS: Twenty-three periodontally healthy subjects (mean age 32.5 years that required crown lengthening surgery in premolars were recruited. In a total of 30 premolars, full thickness flaps, osseous resection, and flap suturing were performed. The restorative margin was defined in the pre-surgical phase and maintained unaltered during the healing period, serving as a reference point. Standardized bitewing radiographs were taken before and after osseous reduction, and at 2, 3, 6, and 12-month healing periods. RESULTS: Intact lamina dura was observed at both mesial and distal alveolar crests only from the 3rd month. At 12-months, all alveolar crests presented lamina dura. The overall mean distance from the restorative margin to the alveolar crest achieved after osseous resection was 3.28±0.87 mm at mesial and 2.81±0.51 mm at distal sites. No significant radiographic changes in the bone crest were observed during a 12-month healing period. CONCLUSION: The findings of this study suggest that the radiographic proximal bone level observed on bitewing radiographs following crown lengthening surgery can be used as a reference to predict the future level of the healed alveolar crest.

  10. SURGICAL CROWN LENGTHENING: A 12-MONTH STUDY - RADIOGRAPHIC RESULTS*

    Science.gov (United States)

    Diniz, Daniela Eleutério; Okuda, Kalizia Marcela; Fonseca, Clarissa Ribeiro; Gonzalez, Marly Kimie Sonohara; Greghi, Sebastião Luiz Aguiar; do Valle, Accácio Lins; Lauris, José Roberto Pereira

    2007-01-01

    Objective The purpose of this study was to perform a radiographic follow-up evaluation after a 12-month healing period, following crown lengthening surgery. Material and methods Twenty-three periodontally healthy subjects (mean age 32.5 years) that required crown lengthening surgery in premolars were recruited. In a total of 30 premolars, full thickness flaps, osseous resection, and flap suturing were performed. The restorative margin was defined in the pre-surgical phase and maintained unaltered during the healing period, serving as a reference point. Standardized bitewing radiographs were taken before and after osseous reduction, and at 2, 3, 6, and 12-month healing periods. Results Intact lamina dura was observed at both mesial and distal alveolar crests only from the 3rd month. At 12-months, all alveolar crests presented lamina dura. The overall mean distance from the restorative margin to the alveolar crest achieved after osseous resection was 3.28±0.87 mm at mesial and 2.81±0.51 mm at distal sites. No significant radiographic changes in the bone crest were observed during a 12-month healing period. Conclusion The findings of this study suggest that the radiographic proximal bone level observed on bitewing radiographs following crown lengthening surgery can be used as a reference to predict the future level of the healed alveolar crest. PMID:19089145

  11. Timing of ectocranial suture activity in Gorilla gorilla as related to cranial volume and dental eruption.

    Science.gov (United States)

    Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I

    2011-05-01

    Research has shown that Pan and Homo have similar ectocranial suture synostosis patterns and a similar suture ontogeny (relative timing of suture fusion during the species ontogeny). This ontogeny includes patency during and after neurocranial expansion with a delayed bony response associated with adaptation to biomechanical forces generated by mastication. Here we investigate these relationships for Gorilla by examining the association among ectocranial suture morphology, cranial volume (as a proxy for neurocranial expansion) and dental development (as a proxy for the length of time that it has been masticating hard foods and exerting such strains on the cranial vault) in a large sample of Gorilla gorilla skulls. Two-hundred and fifty-five Gorilla gorilla skulls were examined for ectocranial suture closure status, cranial volume and dental eruption. Regression models were calculated for cranial volumes by suture activity, and Kendall's tau (a non-parametric measure of association) was calculated for dental eruption status by suture activity. Results suggest that, as reported for Pan and Homo, neurocranial expansion precedes suture synostosis activity. Here, Gorilla was shown to have a strong relationship between dental development and suture activity (synostosis). These data are suggestive of suture fusion extending further into ontogeny than brain expansion, similar to Homo and Pan. This finding allows for the possibility that masticatory forces influence ectocranial suture morphology.

  12. Assessment of the role of sutures in a lizard skull: a computer modelling study.

    Science.gov (United States)

    Moazen, Mehran; Curtis, Neil; O'Higgins, Paul; Jones, Marc E H; Evans, Susan E; Fagan, Michael J

    2009-01-01

    Sutures form an integral part of the functioning skull, but their role has long been debated among vertebrate morphologists and palaeontologists. Furthermore, the relationship between typical skull sutures, and those involved in cranial kinesis, is poorly understood. In a series of computational modelling studies, complex loading conditions obtained through multibody dynamics analysis were imposed on a finite element model of the skull of Uromastyx hardwickii, an akinetic herbivorous lizard. A finite element analysis (FEA) of a skull with no sutures revealed higher patterns of strain in regions where cranial sutures are located in the skull. From these findings, FEAs were performed on skulls with sutures (individual and groups of sutures) to investigate their role and function more thoroughly. Our results showed that individual sutures relieved strain locally, but only at the expense of elevated strain in other regions of the skull. These findings provide an insight into the behaviour of sutures and show how they are adapted to work together to distribute strain around the skull. Premature fusion of one suture could therefore lead to increased abnormal loading on other regions of the skull causing irregular bone growth and deformities. This detailed investigation also revealed that the frontal-parietal suture of the Uromastyx skull played a substantial role in relieving strain compared with the other sutures. This raises questions about the original role of mesokinesis in squamate evolution.

  13. A STUDY ON METOPIC SUTURE IN CADAVERIC SKULLS OF ASSAMESE PEOPLE

    Directory of Open Access Journals (Sweden)

    Rubi

    2014-09-01

    Full Text Available Metopic suture is formed due to failure of union of the two halves of the frontal bone. Usually the suture disappears by early childhood, but in some cases it persists as complete or incomplete metopic suture throughout life. A complete metopic suture extends from anterior aspect of bregma to the nasion which is known as metopism. The present study is carried out in 126 dry human cadaveric skulls collected from the Dept. of Anatomy, Dept. of Forensic Medicine and Institute of Pharmacy at Assam Medical College & Hospital, Dibrugarh, Assam, and India. Metopic suture was found in 46(36.5% skulls. Metopism was found in 4(3.17% skulls and incomplete metopic suture was seen in 42(33.33% skulls. 80(63.49% skulls did not have metopic suture in any form.

  14. Modified versus classic alar base sutures after LeFort I osteotomy: a systematic review.

    Science.gov (United States)

    Liu, Xianwen; Zhu, Songsong; Hu, Jing

    2014-01-01

    The purpose of this systematic review is to evaluate the efficacy of a new modified alar base cinch suture by comparing it with the commonly used classic alar base suture after LeFort I osteotomy. A comprehensive search strategy was performed to include interventional studies involving the comparisons of alar base suturing methods after LeFort I osteotomy. Data analyses were conducted using the random-effects model. Three studies with 146 participants undergoing LeFort I maxillary osteotomy were included in this review. The results showed that, compared with the classic method, both modified transseptal alar base suture and modified reinsertion sutures significantly decreased postoperative alar and alar base widening. The modified alar base cinch suture was more effective than the classic alar base suture in maintaining preoperative alar and alar base width after LeFort I osteotomy. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Randomized clinical trial comparing manual suture and different models of mechanical suture in the mimicking of bariatric surgery in swine

    Directory of Open Access Journals (Sweden)

    Fernandes MA

    2014-02-01

    Full Text Available Marcos AP Fernandes,1 Bruno MT Pereira,2 Sandra M Guimarães,1 Aline Paganelli,3 Carlos Manoel CT Pereira,1 Claudio Sergio Batista4 1Institute of Obesity and Advanced Video Laparoscopic Surgery of Petropolis, Rio de Janeiro, Brazil; 2Division of Trauma, University of Campinas, São Paulo, Brazil; 3Laboratório de Patologia Micron Cell Diagnóstico, Rio de Janeiro, Brazil; 4Department of Gynecology and Obstetrics, Faculty of Medicine of Petropolis, Rio de Janeiro, Brazil Context and objective: Variations in the ability of surgeons served as motivation for the development of devices that, overcoming individual differences, allow the techniques to be properly performed, and of which the end result was the best possible. Every technique must be reproduced reliably by the majority of surgeons for their results to be adopted and recognized as effective. The aim of this study was to compare the results, from the point of view of anatomic pathology, of manual sutures versus mechanical sutures using different models of linear mechanical staplers, in the procedure of gastroenteroanastomosis and enteroanastomosis in swine. Methods: Thirty-six healthy, adult, male Sus scrofa domesticus pigs, weighing between 20.7 and 25.5 kg, were used. The swine were randomly divided into four groups of nine pigs, according to the type of suture employed: group A, manual suture with Polysorb® 3-0 wire; group B, 80-shear linear stapler (Covidien® Gia 8038-S; group C, 75-shear linear stapler (Ethicon® Tlc 75; and group D, 75-shear linear stapler (Resource® Yq 75-3. A temporal study was established on the seventh postoperative day for histopathological analysis, and the degree of inflammation, fibrosis, and newly formed vessels, as well as the presence or absence of granulation tissue, foreign body granuloma, and necrosis were all evaluated qualitatively and semiquantitatively. The results were analyzed statistically. Results: Observations during the histopathological

  16. [Remote results of surgical treatment of aging ptosis of face and neck tissues].

    Science.gov (United States)

    Ezrokhin, V M; Pavlovich, V A

    2008-01-01

    Remote results of surgical treatment of patients with aging ptosis of face and neck tissues during 15 years are presented. Results were good there where suggested incisions marking was carried out and for those face and neck skin regions which should be corrected. Unsatisfactory results were received in the cases when wounds edges were sewn by uninterrupted blanket sutures without skin deeper layers fixing.

  17. A modified surgical technique for reconstruction of an acute acromioclavicular joint dislocation

    Science.gov (United States)

    Marchie, Anthony; Kumar, Arun; Catre, Melanio

    2009-01-01

    We report a modified surgical technique for reconstruction of coracoclavicular and acromioclavicular ligaments after acute dislocation of acromioclavicular joint using suture anchors. We have repaired 3 consecutive type III acromioclavicular dislocations with good results. This technique is simple and safe and allows anatomical reconstruction of the ligaments in acute dislocations. PMID:20671868

  18. A Case of Intraocular Erosion and Intrusion by an Arruga Suture

    Directory of Open Access Journals (Sweden)

    Takakuni Kitagaki

    2016-03-01

    Full Text Available Purpose: To report a case of intraocular erosion and intrusion by an Arruga suture. Case Report: This study involved a 62-year-old male who had undergone scleral buckling surgery 40 or more years ago at another hospital for rhegmatogenous retinal detachment, as well as trabeculectomy 20 years ago for primary open-angle glaucoma, in his left eye at the same hospital. However, he recently became aware of blurred vision in that eye. Upon examination, iritis was observed in the anterior portion of his left eye, as well as a great number of pigment cell keratoprecipitates on the posterior surface of the cornea. In the ocular fundus, extensive atrophy of the retinal pigment epithelium and partial hyperpigmentation was observed, accompanied by subretinal strands, yet the retina remained attached. Around the entire peripheral area of the retina we observed a ring-shaped protrusion, but we also saw a shiny, filamentous material in the vitreous cavity that penetrated the sclera and choroid, completely extending from the 4- to 8-o'clock position of the scleral buckle protrusion. To treat the iritis in the patient's left eye, we began to administrate low-concentration steroid eye drops, after which the inflammation disappeared. Conclusion: In this study, we experienced a case of intraocular erosion and intrusion by an Arruga suture, and opted to treat the patient with steroid eye drops and conservative follow-up observations unless retinal redetachment and/or vitreous hemorrhage occurs.

  19. A Case of Intraocular Erosion and Intrusion by an Arruga Suture

    Science.gov (United States)

    Kitagaki, Takakuni; Morishita, Seita; Kohmoto, Ryohsuke; Fukumoto, Masanori; Suzuki, Hiroyuki; Sato, Takaki; Kobayashi, Takatoshi; Kida, Teruyo; Nakajima, Masayuki; Ikeda, Tsunehiko

    2016-01-01

    Purpose To report a case of intraocular erosion and intrusion by an Arruga suture. Case Report This study involved a 62-year-old male who had undergone scleral buckling surgery 40 or more years ago at another hospital for rhegmatogenous retinal detachment, as well as trabeculectomy 20 years ago for primary open-angle glaucoma, in his left eye at the same hospital. However, he recently became aware of blurred vision in that eye. Upon examination, iritis was observed in the anterior portion of his left eye, as well as a great number of pigment cell keratoprecipitates on the posterior surface of the cornea. In the ocular fundus, extensive atrophy of the retinal pigment epithelium and partial hyperpigmentation was observed, accompanied by subretinal strands, yet the retina remained attached. Around the entire peripheral area of the retina we observed a ring-shaped protrusion, but we also saw a shiny, filamentous material in the vitreous cavity that penetrated the sclera and choroid, completely extending from the 4- to 8-o'clock position of the scleral buckle protrusion. To treat the iritis in the patient's left eye, we began to administrate low-concentration steroid eye drops, after which the inflammation disappeared. Conclusion In this study, we experienced a case of intraocular erosion and intrusion by an Arruga suture, and opted to treat the patient with steroid eye drops and conservative follow-up observations unless retinal redetachment and/or vitreous hemorrhage occurs. PMID:27099609

  20. Modification of the Bankart reconstruction using a suture anchor.

    Science.gov (United States)

    Traina, S M; Holtgrewe, J L; King, S

    1998-01-01

    A prospective study was done to determine the effectiveness of a suture anchor in doing a Modified Bankart Reconstruction on the traumatic unidirectional Bankart lesion shoulder. From 1989 to 1991, 26 patients encompassing 27 shoulders with recurrent instability had modified Bankart reconstructions. A minimum 18-month follow-up was obtained by examination of 24 patients with telephone interviews done on two patients. The average follow-up was 23.6 months. A 93.1% good-to-excellent result was obtained using the Bankart rating scale. There were no failures or complications. The surgeon involved in the study thought the suture anchor facilitated the attachment of the avulsed capsulolabral complex in doing the Bankart procedure.

  1. Dynamic Observation on the Effects of Different Suture Techniques on the Biomechanical Properties in the Healing of Tendons

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    To identify the best suture techniques for the tendon repair, the biomechanical properties of tendons sutured by different methods were dynamically examined. 140 chickens were divided into 2 groups equally: group A and group B. The tendon of the right side was subjected to injury-repair process, and the tendons of the left sides served as controls in both groups. In group A, "figure-of8" suture, modified Kessler suture and Bunnell suture were used for the 2nd to 4th paws respectively, while in group B, Kleinert suture, Tsuge suture and Ikuta suture were used. On the day 0, 3,7, 14, 21, 28, 42 after operation, 10 animals were sacrificed and the flexor tendons of both sides were harvested for strength test. The results showed that the initial strength of the repaired tendons and the strength after 6 weeks following tendon cut were far below those of intact tendons, irrespective of suture techniques used. With the 6 techniques, the Pmax of tendons repaired by Tsuge suture was increased continually, reaching the highest value on the 42nd day. The Pmax of tendons sutured by the modified Kessler suture was slightly lower than that by Tsuge suture, but it was increased steadily in healing. The tendons repaired by figure-of-8 suture yielded the lowest Pmax. It was concluded that Tsuge suture and modified Kessler suture were the best techniques for tendon repair.

  2. Microsurgical transverse 2-suture intussusception vasoepididymostomy: effectiveness and rationality

    Institute of Scientific and Technical Information of China (English)

    ZHANG Hao; HUANG Wen-tao; RUAN Xing-xing; LI Liao-yuan; DI Jin-ming; LIU Xiao-peng; XIAO Heng-jun

    2013-01-01

    Background 2-Suture longitudinal vasoepididymostomy shows superiority to transverse technique in an animal study; to date,this has not been consistently confirmed in human body.In the present study,we evaluated the effectiveness of 2-suture transverse intussusception vasoepididymostomy and compared the rationality between transverse and longitudinal techniques.Methods From May 2007 to December 2008,we performed 2-suture transverse vasoepididymostomy in 19 consecutive patients,as described by Marmar with modification.Between March 2009 and January 2010,the internal diameter of the vas lumen and the outer diameter of the epididymal tube were measured using microruler (21 patients and 37 sides).Results Three patients lost to follow-up.At the first follow-up period (ranged from 10 to 24 months),the patency rate was 56.3% (9/16) and the natural pregnancy rate was 25% (4/16).At the second follow-up period (ranged from 46 to 63months),the patency rate was 68.8% (11/16),the natural pregnancy rate was 37.5% (6/16),respectively,and the takehome baby rate was 31.3% (5/16).The diameter of the vas lumen and the outer diameter of the epididymal tubule were (0.512±0.046) mm and (0.572±0.051) mm (P <0.001),respectively.Conclusion Transverse 2-suture intussusception vasoepididymostomy is still an effective technique in treating obstructive azoospermia.

  3. Long-term outcome in dogs after surgical repair of cranial cruciate ligament disease

    OpenAIRE

    MölsÀ, Sari

    2014-01-01

    Cranial cruciate ligament (CCL) disease is one of the most common causes of lameness in dogs. Surgical treatment is recommended to stabilize the stifle joint, alleviate pain, and delay the progression of osteoarthritis (OA). A variety of surgical techniques has been introduced and can be broken down into the more traditional intracapsular ligament replacement and extracapsular suture techniques and the newer neutralizing dynamic osteotomy techniques. Although an enormous amount of literature ...

  4. Surgical Management of a Completely Avulsed Adductor Longus Muscle in a Professional Equestrian Rider

    Directory of Open Access Journals (Sweden)

    Conal Quah

    2014-01-01

    Full Text Available Avulsion injuries of the adductor longus muscle tendon are rare and a challenge to manage especially in athletes. There has been little published literature on the outcome of conservative and operative treatment for these injuries. We report the first case of an acute adductor longus avulsion injury which was surgically repaired in a professional equestrian rider. Return to full preinjury function was achieved at 3 months with surgical repair using 3 suture anchors.

  5. The south Zagros suture zone in teleseismic images

    Science.gov (United States)

    Motaghi, K.; Shabanian, E.; Tatar, M.; Cuffaro, M.; Doglioni, C.

    2017-01-01

    The geometry of intra-continental lithosphere boundaries along the Zagros orogenic belt in the Arabia-Eurasia collision is investigated by means of teleseismic data. The data are gathered over a seismic linear profile extending across south Zagros, the Sanandaj-Sirjan metamorphic zone, the Urumieh-Dokhtar magmatic arc, Central Iran, and the Kopeh Dagh - Binalud mountains. We exploit the P and S receiver functions leading to map the geometry of the crustal and subcrustal interfaces. The migrated depth sections reveal an abrupt crustal thickening and a gentle crustal thinning 60 km north and 30 km south of the Zagros suture, respectively. Associated to the buckled antiformal Moho south of the suture, a deeper synform in the lithospheric lid of the lower Arabia plate is shown by migrated depth sections affecting the lithospheric mantle of the Arabia plate beneath the suture zone. This geometry implies an unexpected intra-lid decoupling. These features imply that the Central Iran lithosphere acts as a relatively strong backstop producing significant internal deformation expressed by shortening and thickening at the edge of the Arabian lithosphere. The 410 km and 660 km transition zones are imaged by P to S converted phases and showed lateral continuity implying an originally low dip angle subduction of the oceanic Arabian plate beneath Central Iran.

  6. 21 CFR 74.3106 - D&C Blue No. 6.

    Science.gov (United States)

    2010-04-01

    ... material for coloring plain or chromic collagen absorbable sutures for general surgical use; (iii) Not to exceed 0.5 percent by weight of the suture material for coloring plain or chromic collagen absorbable sutures for ophthalmic surgical use; (iv) Not to exceed 0.5 percent by weight of the suture material...

  7. Performance Assessment of Bi-Directional Knotless Tissue-Closure Devices in Juvenile Chinook Salmon Surgically Implanted with Acoustic Transmitters, 2009 - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Woodley, Christa M.; Wagner, Katie A.; Bryson, Amanda J.

    2012-11-09

    The purpose of this report is to assess the performance of bi-directional knotless tissue-closure devices for use in tagging juvenile salmon. This study is part of an ongoing effort at Pacific Northwest National Laboratory (PNNL) to reduce unwanted effects of tags and tagging procedures on the survival and behavior of juvenile salmonids, by assessing and refining suturing techniques, suture materials, and tag burdens. The objective of this study was to compare the performance of the knotless (barbed) suture, using three different suture patterns (treatments: 6-point, Wide “N”, Wide “N” Knot), to the current method of suturing (MonocrylTM monofilament, discontinuous sutures with a 2×2×2×2 knot) used in monitoring and research programs with a novel antiseptic barrier on the wound (“Second Skin”).

  8. Transferability of Virtual Reality, Simulation-Based, Robotic Suturing Skills to a Live Porcine Model in Novice Surgeons: A Single-Blind Randomized Controlled Trial.

    Science.gov (United States)

    Vargas, Maria V; Moawad, Gaby; Denny, Kathryn; Happ, Lindsey; Misa, Nana Yaa; Margulies, Samantha; Opoku-Anane, Jessica; Abi Khalil, Elias; Marfori, Cherie

    To assess whether a robotic simulation curriculum for novice surgeons can improve performance of a suturing task in a live porcine model. Randomized controlled trial (Canadian Task Force classification I). Academic medical center. Thirty-five medical students without robotic surgical experience. Participants were enrolled in an online session of training modules followed by an in-person orientation. Baseline performance testing on the Mimic Technologies da Vinci Surgical Simulator (dVSS) was also performed. Participants were then randomly assigned to the completion of 4 dVSS training tasks (camera clutching 1, suture sponge 1 and 2, and tubes) versus no further training. The intervention group performed each dVSS task until proficiency or up to 10 times. A final suturing task was performed on a live porcine model, which was video recorded and blindly assessed by experienced surgeons. The primary outcomes were Global Evaluative Assessment of Robotic Skills (GEARS) scores and task time. The study had 90% power to detect a mean difference of 3 points on the GEARS scale, assuming a standard deviation (SD) of 2.65, and 80% power to detect a mean difference of 3 minutes, assuming an SD of 3 minutes. There were no differences in demographics and baseline skills between the 2 groups. No significant differences in task time in minutes or GEARS scores were seen for the final suturing task between the intervention and control groups, respectively (9.2 [2.65] vs 9.9 [2.07] minutes, p = .406; and 15.37 [2.51] vs 15.25 [3.38], p = .603). The 95% confidence interval for the difference in mean task times was -2.36 to .96 minutes and for mean GEARS scores -1.91 to 2.15 points. Live suturing task performance was not improved with a proficiency-based virtual reality simulation suturing curriculum compared with standard orientation to the da Vinci robotic console in a group of novice surgeons. Published by Elsevier Inc.

  9. [Surgical management of animal bites in children].

    Science.gov (United States)

    Touzet-Roumazeille, S; Jayyosi, L; Plenier, Y; Guyot, E; Guillard, T; François, C

    2016-10-01

    Children represent a population at risk, because of their short size, their naivety and their attraction to animals. The face and hands are the most specific locations in young children. Wounds are often multiple. In more than half the cases, the child knows the animal, which are dogs and cats by frequency argument. The bite episode occurs mostly when the child is alone with the pet without direct supervision, while playing or stroking the animal. As in all bites, pediatric lesions are infectious, functional and aesthetic emergencies, but the goal of this work was primarily to make a point on principles of surgical management of animal bites in children, highlighting pediatric specificities. Animal bites require psychological, anesthetic and surgical treatment, adapted to the child, in a specialized structure. Hospitalization and general anesthesia are more frequent in children. Any suspicion of mistreatment (and/or abuse) should lead to the child's hospitalization, even if wounds do not justify monitoring in a surgical environment. Emergency surgery is essential to limit functional and aesthetic consequences. The healing capacities of the child and the frequent lack of co-morbidity allow a conservative surgical treatment with suture, repositioning skin flaps and controlled healing in the first place. Immobilization, drainage, and antibiotics will complete the surgery. The healing process, however, leads to a specific management during scar remodeling phase and growth. Psychological care of the child and parents should not be forgotten, and has to start at the same time as surgical treatment at in acute phase.

  10. Stress and strain analysis on the anastomosis site sutured with either epineurial or perineurial sutures after simulation of sciatic nerve injury

    Institute of Scientific and Technical Information of China (English)

    Guangyao Liu; Qiao Zhang; Yan Jin; Zhongli Gao

    2012-01-01

    The magnitude of tensile stress and tensile strain at an anastomosis site under physiological stress is an important factor for the success of anastomosis following suturing in peripheral nerve injury treatment.Sciatic nerves from fresh adult cadavers were used to create models of sciatic nerve injury.The denervated specimens underwent epineurial and perineurial suturing.The elastic modulus (40.96 ± 2.59 MPa) and Poisson ratio (0.37 ± 0.02) of the normal sciatic nerve were measured by strain electrical measurement.A resistance strain gauge was pasted on the front,back,left,and right of the edge of the anastomosis site after suturing.Strain electrical measurement results showed that the stress and strain values of the sciatic nerve following perineurial suturing were lower than those following epineurial suturing.Scanning electron microscopy revealed that the sciatic nerve fibers were disordered following epineurial compared with perineurial suturing.These results indicate that the effect of perineurial suturing in sciatic nerve injury repair is better than that of epineurial suturing.

  11. New suture techniques for best esthetic skin healing Novas técnicas de suturas para melhor cicatrização estética da pele

    Directory of Open Access Journals (Sweden)

    Otoni Moreira Gomes

    2012-07-01

    Full Text Available PURPOSE: To report two new suture techniques for best esthetic skin healing. METHODS: Using the pig skin slices routinely employed for surgical technique training two new types of skin sutures were performed. One defined as inverted or hidden X point suture and other as totally hidden intradermal running suture. The first were performed using 4-0 polypropilene stitch and the intradermal with 4-0 poliglicolic stitch. RESULTS: It was confirmed good skin layers union and contention with best esthetic result than observed with the traditional X and intradermal suture techniques. CONCLUSION: Macroscopic examination of the hidden X point and totally hidden intra-dermal sutures and centrifuge skin traction confirmed good skin layers union and contention with best esthetic result than observed with the traditional X and intradermal sutures techniques.OBJETIVO: Apresentar dois novos tipos de suturas para melhor resultado estético na cicatrização da pele. METODOS: Utilizando fragmentos de pele de porco rotineiramente empregados no ensino e treinamento de técnica operatória, dois novos tipos de suturas da pele foram desenvolvidos. Um deles definido como sutura com pontos em X invertidos ou ocultos e outro como sutura intradérmica totalmente oculta. A primeira foi realizada com fio de polipropileno 4-0, e a intradérmica oculta com fio poliglicólico 4-0. RESULTADOS: Foram confirmados contenção e união adequada das camadas da pele com melhores resultados estético do que observados com as suturas tradicionais em X e intradémica. CONCLUSÃO: A análise macroscópica das suturas com pontos em X oculto e intradermica totalmente oculta e a tração centrífuga da bordas suturadas confirmaram boa união das camadas da pele com melhor resultado estético do que observado com as suturas em X e intradérmicas tradicionais.

  12. An in-vitro study of rotator cuff tear and repair kinematics using single- and double-row suture anchor fixation

    Directory of Open Access Journals (Sweden)

    Angela E Kedgley

    2013-01-01

    Full Text Available Purpose: Double-row suture anchor fixation of the rotator cuff was developed to reduce repair failure rates. The purpose of this study was to determine the effects of simulated rotator cuff tears and subsequent repairs using single- and double-row suture anchor fixation on three-dimensional shoulder kinematics. It was hypothesized that both single- and double-row repairs would be effective in restoring active intact kinematics of the shoulder. Materials and Methods: Sixteen fresh-frozen cadaveric shoulder specimens (eight matched pairs were tested using a custom loading apparatus designed to simulate unconstrained motion of the shoulder. In each specimen, the rotator cuff was sectioned to create a medium-sized (2 cm tear. Within each pair, one specimen was randomized to a single-row suture anchor repair, while the contralateral side underwent a double-row suture anchor repair. Joint kinematics were recorded for intact, torn, and repaired scenarios using an electromagnetic tracking device. Results: Active kinematics confirmed that a medium-sized rotator cuff tear affected glenohumeral kinematics when compared to the intact state. Single- and double-row suture anchor repairs restored the kinematics of the intact specimen. Conclusions: This study illustrates the effects of medium-sized rotator cuff tears and their repairs on active glenohumeral kinematics. No significant difference ( P ≥ 0.10 was found between the kinematics of single- and double-row techniques in medium-sized rotator cuff repairs. Clinical Relevance: Determining the relative effects of single- and double-row suture anchor repairs of the rotator cuff will allow physicians to be better equipped to treat patients with rotator cuff disease.

  13. Sensorization of a surgical robotic instrument for force sensing

    Science.gov (United States)

    Shahzada, Kaspar S.; Yurkewich, Aaron; Xu, Ran; Patel, Rajni V.

    2016-03-01

    This paper presents the development and application of an approach for sensorizing a surgical robotic instrument for two degree-of-freedom (DOF) lateral force sensing. The sensorized instrument is compatible with the da Vinci® Surgical System and can be used for skills assessment and force control in specific surgical tasks. The sensing technology utilizes a novel layout of four fiber Bragg grating (FBG) sensors attached to the shaft of a da Vinci® surgical instrument. The two cross-section layout is insensitive to error caused by combined force and torque loads, and the orientation of the sensors minimizes the condition number of the instrument's compliance matrix. To evaluate the instrument's sensing capabilities, its performance was tested using a commercially available force-torque sensor, and showed a resolution of 0.05N at 1 kHz sampling rate. The performance of the sensorized instrument was evaluated by performing three surgical tasks on phantom tissue using the da Vinci® system with the da Vinci Research Kit (dVRK): tissue palpation, knot tightening during suturing and Hem-O-Lok® tightening during knotless suturing. The tasks were designed to demonstrate the robustness of the sensorized force measurement approach. The paper reports the results of further evaluation by a group of expert and novice surgeons performing the three tasks mentioned above.

  14. ASTIGMATIC OUTCOME & POST OPERATIVE RECOVERY IN PAT IENTS UNDERGOING PTERYGIUM EXCISION WITH CONJUNCTIVAL AUTOGRAFTS. COMPARISION BETWEEN SUTURE & AUTOLOGUS BLOOD FIBRIN

    Directory of Open Access Journals (Sweden)

    Smita Dileep

    2013-06-01

    Full Text Available ABSTRACT : AIMS: To review the effect of surgery type on the postop erative recovery & astigmatism in pterygium surgery. SETTINGS AND DESIGN: Randomized comparative clinical trial. MATERIALS AND METHODS: Forty six patients (46 eyes with primary pterygiu m were randomised to undergo pterygium surgery using eithe r autologous fibrin glue (23 eyes or 10-0 nylon sutures (23 eyes to attach the conjunctival autograft. The patients were followed up 1day, 1wk, 2wks & 6 w eeks. Outcome measures were keratometry changes & postope rative recovery.. The preoperative and postoperative keratometric measurements, evaluated using keratometer, were noted. RESULTS: Corneal astigmatism was significantly reduced in th e total group from 2.94(SD- 0.52 diopter to 1.91 (sd 0.57 diopter (p 0.05. The intensity of the postoperative watering, itchin g, were significantly lower in the autologous fibrin glue group than in the suture gro up (p<0.001. Postoperative redness was absent in 47.82% (11cases and mild in 52.18% (13 cases 2 weeks postoperatively in the autologous fibrin group while in sutured group 17.4% (4cases had mild redness and 82.6% (19 cases had moderate redness 2weeks postoperatively.

  15. Vascular Z-shaped ligation technique in surgical treatmentof haemorrhoid

    Institute of Scientific and Technical Information of China (English)

    KazIm Gemici; Ahmet Okus; Serden Ay

    2015-01-01

    AIM To present the effectiveness of minimal invasivevascular zet ligation in the surgical treatment ofhaemorrhoidal disease (HD).METHODS: Among 138 patients with 2nd-4th gradeinternal HD having several complaints and operatedat our hospital between 2003-2013; 116 patients whoregularly attended 1-year control were included in thestudy. Operation times, postoperative early period pain,satisfaction score, complications and relapse detailswere obtained from computer records retrospectively.Visual Analogous Scale (VAS) scores were used forpatient satisfaction on the 3rd, 7th and 21st days.Technique; fixed suture which is constituted by thefirst leg of the Z-shaped suture (to pass by the mucosaand muscular layer) was put in the pile root in order toensure vascular ligation and fixation. The second legof the Z-shaped suture is constituted by mobile sutureand it passes by the pile mucosa and submucosa whichprolapses 5-10 mm below the first suture.RESULTS: Seventy-five of the patients (65%) weremale, 41 of them (35%) were female and their ageaverage was 41. The mean operation time was 12 ±4.8 min. VAS/satisfaction score was found as 2.2/4.3,1.8/4.0, 1.2/4.4 respectively on the 3rd, 7th, and 21stdays. Four of the patient (3.5%) had relapse.CONCLUSION: This technique is an easily applicable,cost efficient way of operation which increases patientsatisfaction.

  16. Ultrastructure, Histochemistry, and Mineralization Patterns in the Ecdysial Suture of the Blue Crab, Callinectes sapidus

    Science.gov (United States)

    Priester, Carolina; Dillaman, Richard M.; Gay, D. Mark

    2005-12-01

    The ecdysial suture is the region of the arthropod exoskeleton that splits to allow the animal to emerge during ecdysis. We examined the morphology and composition of the intermolt and premolt suture of the blue crab using light microscopy and scanning electron microscopy. The suture could not be identified by routine histological techniques; however 3 of 22 fluorescein isothiocyanate-labeled lectins tested (Lens culinaris agglutinin, Vicia faba agglutinin, and Pisum sativum agglutinin) differentiated the suture, binding more intensely to the suture exocuticle and less intensely to the suture endocuticle. Back-scattered electron (BSE) and secondary electron observations of fracture surfaces of intermolt cuticle showed less mineralized regions in the wedge-shaped suture as did BSE analysis of premolt and intermolt resin-embedded cuticle. The prism regions of the suture exocuticle were not calcified. X-ray microanalysis of both the endocuticle and exocuticle demonstrated that the suture was less calcified than the surrounding cuticle with significantly lower magnesium and phosphorus concentrations, potentially making its mineral more soluble. The presence or absence of a glycoprotein in the organic matrix, the extent and composition of the mineral deposited, and the thickness of the cuticle all likely contribute to the suture being removed by molting fluid, thereby ensuring successful ecdysis.

  17. [Severe cartilage loss caused by metallic anchors in surgical treatment of a Bankart lesion: report of three cases].

    Science.gov (United States)

    Bek, Doğan; Ege, Tolga; Erdem, Yusuf; Tunay, Servet

    2015-01-01

    Currently, arthroscopic modalities in the surgical treatment of shoulder instability using suture anchors are more popular than open surgery. However, there are some complications related to the metallic suture anchors used. One of the most common complications is cartilage loss due to shallow placement of the suture anchor. Herein, we report three cases with severe cartilage loss of the humeral head due to metallic proud anchors, including one of whom requiring total shoulder arthroplasty. In conclusion, it is essential to place the suture anchors in an appropriate position and deepness. In case of any doubt, they should be removed or in non-threaded anchors, they should be inserted fully inside the glenoid with an impactor and a hammer to avoid serious cartilage loss.

  18. Effectiveness of human amnion as a graft material in lower anterior ridge vestibuloplasty: a clinical study.

    Science.gov (United States)

    Sharma, Yogesh; Maria, Anisha; Kaur, Preeti

    2011-12-01

    The aim of this study is to evaluate the clinical use of amnion as a biodegradable graft material for lower anterior ridge vestibuloplasty. Ten patients who had been referred for preprosthetic surgery underwent mandibular anterior ridge vestibuloplasty using Clark's technique and amniotic membrane as a graft material. Preoperative vestibular depth was measured. Fresh amniotic membrane was placed in the surgical site and sutured with 4-0 vicryl. In all ten cases suction catheter stent was used and was secured in the depth of the vestibule by using 1-0 mersilk percutaneous sutures. Vestibular depths were measured using a divider and a scale. Post operative measurements were taken at the end of 10th day, 1st month and 3rd month. And an average gain of 4-6 mm in the depth of the labial vestibule was noted. Amniotic membrane can be a favorable graft material for vestibuloplasty, promoting healing and preventing relapse. It is easily available and preserved and a cost effective material.

  19. Surgical instruction for general practitioners: how, who and how often?

    LENUS (Irish Health Repository)

    Collins, Anne M

    2010-07-01

    Educational programmes, designed to meet the training needs of General Practitioners (GPs) performing minor surgical procedures, have previously been shown to increase their surgical workload. The change in the level of competence following these programmes has not been assessed. The aims of this study were two-fold: to evaluate the vertical mattress suture for construct validity and to assess the impact of plastic surgery training on the surgical skill of GPs. Thirty non-consultant hospital doctors and 27 self-selected GPs were included. Using a modified objective structured assessment of technical skills (OSATS) scoring system, construct validity of the vertical mattress suture was confirmed. The median total OSATS score was 16 points (26.7%) in the novice group (medical registrars), 38.5 points (64.2%) in the intermediate group (surgical SHOs) and 59 points (98.3%) in the expert group (surgical registrars, p<0.001, Kruskal-Wallis test). Objective assessment in the GP group immediately following practical instruction revealed a median overall improvement of 31.7% (19 points) in total OSATS scores (p<0.001, Friedman non-parametric test, F). At six months follow-up all course participants had improved compared to their baseline. A median overall improvement of 13 points (21.7%) was noted (p<0.001, F). However, the majority (80%, n=20) had deteriorated from the standard set immediately after the course with a median overall reduction in total OSATS scores of six points (10%, p=0.001, F). Plastic surgery training is immediately efficacious in improving the technical proficiency of GPs. Through objective assessment of a standardised suture task we demonstrated a low rate of educational decay of 10% over a six-month period.

  20. Surgical treatment of post-infarction left ventricular pseudoaneurysm: Case series highlighting various surgical strategies.

    Science.gov (United States)

    Prifti, Edvin; Bonacchi, Massimo; Baboci, Arben; Giunti, Gabriele; Veshti, Altin; Demiraj, Aurel; Zeka, Merita; Rruci, Edlira; Bejko, Ervin

    2017-04-01

    The left ventricular pseudoaneurysm (LVP) is rare, the surgical experience is limited and its surgical treatment remains still a challenge with an elevated mortality. Herein, it is presented a retrospective analysis of our experience with acquired post infarct LVP over a10-year period. Between January 2006 through August 2016, a total of 13 patients underwent operation for post infarct pseudoaneurysm of the left ventricle. There were 10 men and 3 women and the mean age was 61 ± 7.6 years. 4 patients presented acute LVP. Two patients had preoperative intraortic balloon pump implantation. Various surgical techniques were used to obliterate the pseudoaneurysm such as direct pledgeted sutures buttressed by polytetrafluoroethylene felt, a Gore-Tex or Dacron patch, transatrial closure of LVP neck in submitral pseudoaneurysm, or linear closure in cases presenting associated postinfarct ventricular septal defect. Concomitant coronary artery bypasses were performed for significant stenoses in 12 patients, ventricular septal defect closure in 4 patients, mitral valve replacement in 3 and aortic valve replacement in 1 patient. Operative mortality was 30.8% (4 patients). Three of them were acute LVP. Three patients required the continuous hemodyalisis and 8 patients required intra-aortic balloon pump. At follow-up two deaths occurred at 1 and 3 years after surgery. In conclusion, this study revealed that surgical repair of post infarct left ventricular pseudoaneurysm was associated with an acceptable surgical mortality rate, that cardiac rupture did not occur in surgically treated patients.

  1. O papel do adesivo de fibrina e da sutura na fixação do transplante de menisco preservado por ultracongelamento em coelhos The role of fibrin glue and suture on the fixation of ultra frozen preserved meniscus transplantation in rabbits

    Directory of Open Access Journals (Sweden)

    Leandro José Reckers

    2009-10-01

    Full Text Available OBJETIVO: Avaliar a capacidade do adesivo de fibrina em promover a fixação do menisco ao longo de duas, quatro e oito semanas comparando com a técnica convencional de fixação por sutura a tecidos moles. MÉTODOS: 36 meniscos mediais direitos de coelhos preservados a 73°C negativos por 30 dias foram transplantados para os animais da mesma amostra e fixados com sutura ou cola de fibrina. Após duas, quatro ou oito semanas a aparência dos meniscos e a qualidade da fixação foram verificadas macroscopicamente e avaliadas por um sistema de escores. Os achados foram submetidos a estudo estatístico de análise de variância por postos (p OBJECTIVE: To evaluate the ability of fibrin adhesive in promoting the meniscus fixation within two, four and eight weeks compared to the conventional soft-tissue suture technique. MATERIALS AND METHODS: 36 right medial menisci of rabbits preserved at negative 73° Celsius for 30 days were transplanted to animals of the same sample and fixed with soft-tissue suture or fibrin glue. After 2, 4 or 8 weeks, the appearance of the menisci and the quality of fixation were macroscopically checked and evaluated by a scoring system. The findings were subjected to the statistical study of variance analysis (p < 0.05%. RESULTS: The deep-frozen meniscus preservation maintained the integrity of the meniscus transplant, and, macroscopically, there was no significant reduction of the length of the meniscus in all post-transplant periods (p = 0.015. The menisci fixed with fibrin showed slight changes in color and surface roughness. There were no signs of rejection or infection in both groups. Suture fixation scoring was superior (p = 0.015 in all periods (80% of total fixation as compared to the setting promoted by fibrin (20% of total fixation. CONCLUSION: The homologous transplantation of the meniscus of rabbits experienced various degrees of integration to the knee according to the fixation method; the surgical soft tissues

  2. Keratometric astigmatism after ECCE in eastern Nepal. Continuous versus interrupted sutures.

    Science.gov (United States)

    Sood, Archana; Thakur, Sanjay Kumar D; Kumar, Sandeep; Badhu, Badri

    2003-03-01

    The study aimed to compute and compare the keratometric astigmatism induced by wound closure with continuous and interrupted sutures in conventional extracapsular cataract extraction with intraocular lens implantation at a single centre in eastern Nepal. Sixty eyes of 60 patients were included in the study. All patients received conventional extracapsular cataract extraction and single piece modified C-loop posterior chamber intraocular lens. Thirty eyes were sutured with continuous (Group 1) and 30 eyes with interrupted sutures (Group 2). The results were analysed by the unpaired student's t-test. At the end of 6 weeks, Group 1 patients had significantly higher astigmatism (3.53 +/- 2.19D) compared to Group 2 patients (1.7 +/- 1.35). A majority of patients in both groups had with-the-rule astigmatism throughout the postoperative period. Interrupted sutures cause less astigmatism than continuous suture. The factors responsible for high astigmatism in continuous sutures call for further analysis.

  3. 3D printed, bio-inspired prototypes and analytical models for structured suture interfaces with geometrically-tuned deformation and failure behavior

    Science.gov (United States)

    Lin, Erica; Li, Yaning; Ortiz, Christine; Boyce, Mary C.

    2014-12-01

    Geometrically structured interfaces in nature possess enhanced, and often surprising, mechanical properties, and provide inspiration for materials design. This paper investigates the mechanics of deformation and failure mechanisms of suture interface designs through analytical models and experiments on 3D printed polymer physical prototypes. Suture waveforms with generalized trapezoidal geometries (trapezoidal, rectangular, anti-trapezoidal, and triangular) are studied and characterized by several important geometric parameters: the presence or absence of a bonded tip region, the tip angle, and the geometry. It is shown that a wide range (in some cases as great as an order of magnitude) in stiffness, strength, and toughness is achievable dependent on tip bonding, tip angle, and geometry. Suture interfaces with a bonded tip region exhibit a higher initial stiffness due to the greater load bearing by the skeletal teeth, a double peak in the stress-strain curve corresponding to the failure of the bonded tip and the failure of the slanted interface region or tooth, respectively, and an additional failure and toughening mechanism due to the failure of the bonded tip. Anti-trapezoidal geometries promote the greatest amplification of properties for suture interfaces with a bonded tip due the large tip interface area. The tip angle and geometry govern the stress distributions in the teeth and the ratio of normal to shear stresses in the interfacial layers, which together determine the failure mechanism of the interface and/or the teeth. Rectangular suture interfaces fail by simple shearing of the interfaces. Trapezoidal and triangular suture interfaces fail by a combination of shear and tensile normal stresses in the interface, leading to plastic deformation, cavitation events, and subsequent stretching of interface ligaments with mostly elastic deformation in the teeth. Anti-trapezoidal suture interfaces with small tip angles have high stress concentrations in the teeth

  4. The effect of music on robot-assisted laparoscopic surgical performance.

    Science.gov (United States)

    Siu, Ka-Chun; Suh, Irene H; Mukherjee, Mukul; Oleynikov, Dmitry; Stergiou, Nick

    2010-12-01

    Music is often played in the operating room to increase the surgeon's concentration and to mask noise. It could have a beneficial effect on surgical performance. Ten participants with limited experience with the da Vinci robotic surgical system were recruited to perform two surgical tasks: suture tying and mesh alignment when classical, jazz, hip-hop, and Jamaican music were presented. Kinematics of the instrument tips of the surgical robot and surface electromyography of the subjects were recorded. Results revealed that a significant music effect was found for both tasks with decreased time to task completion (P = .005) and total travel distance (P = .021) as well as reduced muscle activations ( P = .016) and increased median muscle frequency (P = .034). Subjects improved their performance significantly when they listened to either hip-hop or Jamaican music. In conclusion, music with high rhythmicity has a beneficial effect on robotic surgical performance. Musical environment may benefit surgical training and make acquisition of surgical skills more efficient.

  5. Photometric analysis of absorbable barbed suture for periareolar closure in mastopexy

    Institute of Scientific and Technical Information of China (English)

    Allen D Rosen; Alanna M Guzman; Teresa Hartman

    2016-01-01

    Aim:The primary author previously described his technique for periareolar closure in mastopexy using a pinwheel interlocking purse string with absorbable barbed suture and now reports the results of a retrospective photometric analysis comparing this technique with the same closure using Gortex® suture. This study is designed to compare the degree of areolar widening and safety proifle of using absorbable barbed sutures for periareolar closure versus permanent smooth suture. Methods:A retrospective chart review was conducted of all patients whose periareolar closures were performed using an interlocking purse-string technique over a 10-year period. Only patients undergoing circumvertical mastopexy were included. All had photometric evaluation and follow-up performed within 6-24 months. Results:In total, 20 patients (40 areolas), which were closed with absorbable barbed suture, were analyzed photometrically. In this suture group, areola size increased a mean of 4.9%from baseline, and no complications (0%) were observed. This compared favorably with previously reported complication rates using permanent sutures and with a series of cases presented herein in which permanent smooth suture was used for purse string closure. The degree to which absorbable barbed suture controls areolar spread was shown to be signiifcantly better than those where permanent smooth purse string techniques were employed. Conclusion:Circumvertical mastopexy closures using absorbable barbed suture was shown to be safe and effective and compared favorably to older techniques using permanent smooth suture for similar closures. This paper lends support to the safety of using absorbable barbed suture in circumareolar closures to limit areolar spread.

  6. 21 CFR 74.3206 - D&C Green No. 6.

    Science.gov (United States)

    2010-04-01

    ... coloring poly(glycolic acid-co-trimethylene carbonate) sutures (also referred to as 1,4-dioxan-2,5-dione... suture material for coloring polyglycolic acid surgical sutures with diameter greater than U.S.P. size 8... material for coloring polyglycolic acid surgical sutures with diameter not greater than U.S.P. size...

  7. Extrusion of bone anchor suture following flexor digitorum profundus tendon avulsion injury repair.

    LENUS (Irish Health Repository)

    Tiong, William H C

    2011-09-01

    Flexor digitorum profundus (FDP) zone I tendon avulsion injury is traditionally repaired with a pullout suture technique. More recently, bone anchor sutures have been used as a viable alternative and have largely replaced areas in hand surgery where pullout suture technique was once required. To date, there have been very few complications reported related to bone anchor suture use in FDP tendon reattachment to the bone. We report a very unusual case of extrusion of bone anchor through the nailbed, 6 years after zone I FDP tendon avulsion injury repair and a brief review of literature.

  8. Effect of residents' previous laparoscopic surgery experience on initial robotic suturing experience.

    Science.gov (United States)

    Kilic, Gokhan Sami; Walsh, Teresa M; Borahay, Mostafa; Zeybek, Burak; Wen, Michael; Breitkopf, Daniel

    2012-01-01

    Objective. To assess the impact of gynecology residents' previous laparoscopic experience on the learning curve of robotic suturing techniques and the value of initial structured teaching in dry lab prior to surgery. Methods. Thirteen gynecology residents with no previous robotic surgery experience were divided into Group 1, consisting of residents with 2 or fewer laparoscopic experiences, and Group 2, consisting of residents with 3 or more laparoscopic experiences. Group 1 had a dry-laboratory training in suturing prior to their initial experience in the operating room. Results. For all residents, it took on average 382 ± 159 seconds for laparoscopic suturing and 326 ± 196 seconds for robotic suturing (P = 0.12). Residents in Group 1 had a lower mean suture time than residents in Group 2 for laparoscopic suturing (P = 0.009). The residents in Group 2, however, had a lower mean suture time on the robot compared to Group 1 (P = 0.5). Conclusion. Residents with previous laparoscopic suturing experience may gain more from a robotic surgery experience than those with limited laparoscopic surgery experience. In addition, dry lab training is more efficient than hands-on training in the initial phase of teaching for both laparoscopic and robotic suturing skills.

  9. Radiographic and microscopic anatomy of the mid-palatal suture in the elderly.

    Science.gov (United States)

    N'Guyen, T; Ayral, X; Vacher, C

    2008-02-01

    In a previous radiological study of the mid-palatal suture, it has been demonstrated that its obliteration was occurring during adult life and varied. In order to determine the histological status of mid-palatal suture in elderly men, 20 human palates aged more than 70 were examined by occlusal radiographs and histological study of the suture. In all palates the suture was ossified in the anterior thirds and made of conjunctive tissue in the posterior third. This particular evolution could be correlated to the mastication forces acting on the maxillary bones during the entire life.

  10. Effectivity of intraoperative adjustable suture technique in horizontal strabismus

    Directory of Open Access Journals (Sweden)

    Ayse Gul Kocak Altintas

    2013-08-01

    Full Text Available AIM:To compare the long-term effectivity of intraoperative adjustable suture technique with traditional non-adjustable strabismus surgery.METHODS:Two hundred and thirty-three patients, who underwent strabismus surgery either with traditional procedures or one-stage intraoperative adjustable suture technique, were included in our long-term follow-up study. One hundred and eighteen patients were evaluated in traditional surgery group (TSG and 115 who underwent adjustable suture were in the one-stage intraoperative adjustable surgery group (ASG. In this group 9 patients had paralytic strabismus and 16 had reoperations, 2 patients had restrictive strabismus related to thyroid eye disease. The mean follow up in the TSG was 26.2 months and it was 24.8 months in the ASG group.RESULTS:In patients with exotropia (XT the mean correction of deviation for near fixation in ASG (32.4±13.2PD and in TSG (26.4±8.2PD were similar (P=0.112. The correction for distant fixation in ASG (33.2±11.4PD and TSG (30.9±7.2PD were not significantly different (P=0.321. In patients with esotropia (ET even the mean correction of deviation for both near (31±12PD and distant (30.6±12.8PD fixations were higher in ASG than in TSG, for both near (28.27±14.2PD and distant (28.9±12.9PD fixations, the differences were not significant (P=0.346, 0.824 respectively. The overall success rate of XT patient was 78.9% in TSG and 78.78% in ASG, the difference was not significant (P=0.629. The success rates were 78.75% in TSG and 75.51% in ASG in ET patient, which was also not significantly different (P=0.821.CONCLUSION:Although patients in ASG had more complex deviation such as paralysis, reoperations and restrictive strabismus, success rates of this tecnique was as high as TSG which did not contain complicated deviation. One-stage intraoperative adjustable suture technique is a safe and effective method for cooperative patient who has complex deviation.

  11. Paleomagnetic reconstruction of the Neotethyan Suture in Central Anatolia (Turkey)

    Science.gov (United States)

    Ozkaptan, M.; Gulyuz, E.; Kaymakci, N.; Langereis, C. G.

    2016-12-01

    The consumption of the Neo-Tethyan Ocean and the accretion of intervening continental blocks such as the Taurides and Kırşehir Block in the south and the Pontides in the north since the Mesozoic occurred along two sutures. The İzmir-Ankara Suture Zone (IASZ) between the Pontides in the north and the Taurides in the south and Intra-Tauride suture Zone (ITSZ) between the Taurides and the Kırşehir block meets around the Haymana Basin. The IASZ follows roughly an E-W trend and makes a sharp bend of approximately of 90° along the western margin of the Çankırı Basin. The ITSZ, on the other hand, follows a NW-SE trend parallel to the Tuz Gölü Fault Zone and overprinted by the structures related to the İASZ in the north. From West to East; the Haymana, Tuz Gölü and Çankırı basins straddle these suture zones and are developed in relation to the subduction and collision processes, which make them invaluable for unraveling deformation history and evolution of the Neotethys. In this regard we have conducted a very detailed paleomagnetic study to determine vertical axis rotations in the region, mainly on the Late Cretaceous to Recent infill of these basins. Results have shown that the region undergone strong clockwise (CW) and counter-clockwise (CCW) rotations, up to ±90° in places, resulting in the present geometry of the region. The central part of the Haymana Basin rotated as much as 90° CCW sense while its northern parts and the Tuz Gölü basin rotated 30° CW sense, which contradicts with almost all the published paleomagnetic results from the region. The restored geometries, based on new paleomagnetic data indicate that Haymana, Tuz Gölü basins and the SW margin of the Çankırı Basin were initially oriented in N-S direction prior to the Eocene. These results indicate that the most of the paleogeographical maps and evolutionary scenarios and models proposed for the region previously requires major re-thinking and serious revisions.

  12. Total Laparoscopic Hysterectomy: Evaluation of an Evidence-Based Educational Strategy Using a Novel Simulated Suture and Knot-Tying Challenge, the “Holiotomy”

    Directory of Open Access Journals (Sweden)

    Katherine A. O'Hanlan

    2012-01-01

    Full Text Available Objective. The purpose of this study was to evaluate perceptions of skills and practice patterns of gynecologists attending a course on total laparoscopic hysterectomy (TLH. This course employed extensive use of pelvic trainer boxes to accomplish the Holiotomy Challenge. The “Holiotomy Challenge” entailed suturing two plastic pieces with six figure-of-N sutures tied with four square knots each. Methods. A survey was administered before the course and 3 months later. Data were analyzed by paired t-tests, McNemar’s Chi Squares, and ANCOVAs with significance set P<.05. Results. At baseline, 216 surgeons and at 3 months 102 surgeons returned the survey. Surgeons’ self-perceptions of their skills significantly increased from 6.24 to 7.28. Their reports of their surgical practice at home revealed significantly increased rates of minimally invasive procedures, from 42% to 54%. Significantly more surgeons reported having the ability to close the vagina, or a small cystotomy or enterotomy. Participation in the cadaver lab and presence of their practice partner did not impact these rates. Conclusions. A comprehensive course employing laparoscopic surgical simulation focused on basic surgical skills essential to TLH has a positive impact on attendees' self-rated skill level and rate of laparoscopic approaches. Many had begun performing TLH after the course.

  13. Assessment of a manipulator device for NOTES with basic surgical skill tests: a bench study.

    Science.gov (United States)

    Yasuda, Kazuhiro; Kitano, Seigo; Ikeda, Keiichi; Sumiyama, Kazuki; Tajiri, Hisao

    2014-10-01

    Advanced complex surgery performed with the natural orifice translumenal endoscopic surgery technique requires use of a multitasking platform. The aim of this study is to evaluate the basic functionality of a prototype multitasking platform "EndoSAMURAI" with the use of a biosimulation model and ex vivo porcine stomach. We compared the performance of basic surgical skill tasks between the EndoSAMURAI and standard laparoscopic instrumentation. Basic surgical tasks include cutting, dissection, and suturing and knot tying. Main outcome measurements were the time to complete each task and leak pressure to evaluate the quality of the suturi