WorldWideScience

Sample records for surgical specimen measured

  1. Breast surgical specimen radiographs: How reliable are they?

    International Nuclear Information System (INIS)

    Britton, P.D.; Sonoda, L.I.; Yamamoto, A.K.; Koo, B.; Soh, E.; Goud, A.

    2011-01-01

    Radiography of the excised surgical specimen following wire guided localisation of impalpable breast lesions is standard surgical practice. The aims of the study were to establish the reliability of the breast specimen radiograph (SR) in determining lesion excision and to determine whether the radiographic margin correlated with the histological margin. The clinical, imaging, SR and pathological details of 106 patients with a pre-operative diagnosis of breast cancer were retrospectively reviewed. The reliability of orientation was estimated and the appearance and distance from the mammographic abnormality to each radial margin were measured and correlated with surgical histological findings. The overall accuracy of the specimen radiograph in determining whether the mammographic lesion was present was 99%. The SR could be orientated 'very reliably' or 'reliably' in 80% of patients however in only 48% of patients did the closest margin on the SR correspond with the same nearest margin at final histology. A maximum measurement of 11 mm or more from the lesion to the specimen edge was associated with a 77% likelihood of having a clear final histological margin (taken as 5 mm or more) and if <11 mm a 58% chance of having involved final histological margins. There was however a wide overlap in the results with patients having an apparently wide SR margin but histologically involved margins and vice versa. The SR is reliable at determining whether the target lesion has been removed. The correlation of SR margin orientation and measurement with final histological measurement is however far less reliable.

  2. Concordance of DNA methylation profiles between breast core biopsy and surgical excision specimens containing ductal carcinoma in situ (DCIS).

    Science.gov (United States)

    Chen, Youdinghuan; Marotti, Jonathan D; Jenson, Erik G; Onega, Tracy L; Johnson, Kevin C; Christensen, Brock C

    2017-08-01

    The utility and reliability of assessing molecular biomarkers for translational applications on pre-operative core biopsy specimens assume consistency of molecular profiles with larger surgical specimens. Whether DNA methylation in ductal carcinoma in situ (DCIS), measured in core biopsy and surgical specimens are similar, remains unclear. Here, we compared genome-scale DNA methylation measured in matched core biopsy and surgical specimens from DCIS, including specific DNA methylation biomarkers of subsequent invasive cancer. DNA was extracted from guided 2mm cores of formalin fixed paraffin embedded (FFPE) specimens, bisulfite-modified, and measured on the Illumina HumanMethylation450 BeadChip. DNA methylation profiles of core biopsies exhibited high concordance with matched surgical specimens. Within-subject variability in DNA methylation was significantly lower than between-subject variability (all Pcore biopsy and surgical specimens, 15%, and a pathway analysis of these CpGs indicated enrichment for genes related with wound healing. Our results indicate that DNA methylation measured in core biopsies are representative of the matched surgical specimens and suggest that DCIS biomarkers measured in core biopsies can inform clinical decision-making. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  3. Improved compliance with the World Health Organization Surgical Safety Checklist is associated with reduced surgical specimen labelling errors.

    Science.gov (United States)

    Martis, Walston R; Hannam, Jacqueline A; Lee, Tracey; Merry, Alan F; Mitchell, Simon J

    2016-09-09

    A new approach to administering the surgical safety checklist (SSC) at our institution using wall-mounted charts for each SSC domain coupled with migrated leadership among operating room (OR) sub-teams, led to improved compliance with the Sign Out domain. Since surgical specimens are reviewed at Sign Out, we aimed to quantify any related change in surgical specimen labelling errors. Prospectively maintained error logs for surgical specimens sent to pathology were examined for the six months before and after introduction of the new SSC administration paradigm. We recorded errors made in the labelling or completion of the specimen pot and on the specimen laboratory request form. Total error rates were calculated from the number of errors divided by total number of specimens. Rates from the two periods were compared using a chi square test. There were 19 errors in 4,760 specimens (rate 3.99/1,000) and eight errors in 5,065 specimens (rate 1.58/1,000) before and after the change in SSC administration paradigm (P=0.0225). Improved compliance with administering the Sign Out domain of the SSC can reduce surgical specimen errors. This finding provides further evidence that OR teams should optimise compliance with the SSC.

  4. Light Reflectance Spectroscopy to Detect Positive Surgical Margins on Prostate Cancer Specimens.

    Science.gov (United States)

    Morgan, Monica S C; Lay, Aaron H; Wang, Xinlong; Kapur, Payal; Ozayar, Asim; Sayah, Maryam; Zeng, Li; Liu, Hanli; Roehrborn, Claus G; Cadeddu, Jeffrey A

    2016-02-01

    Intraoperative frozen section analysis is not routinely performed to determine positive surgical margins at radical prostatectomy due to time requirements and unproven clinical usefulness. Light reflectance spectroscopy, which measures light intensity reflected or backscattered from tissues, can be applied to differentiate malignant from benign tissue. We used a novel light reflectance spectroscopy probe to evaluate positive surgical margins on ex vivo radical prostatectomy specimens and correlate its findings with pathological examination. Patients with intermediate to high risk disease undergoing radical prostatectomy were enrolled. Light reflectance spectroscopy was performed on suspected malignant and benign prostate capsule immediately following organ extraction. Each light reflectance spectroscopy at 530 to 830 nm was analyzed and correlated with pathological results. A regression model and forward sequential selection algorithm were developed for optimal feature selection. Eighty percent of light reflectance spectroscopy data were selected to train a logistic regression model, which was evaluated by the remaining 20% data. This was repeated 5 times to calculate averaged sensitivity, specificity and accuracy. Light reflectance spectroscopy analysis was performed on 17 ex vivo prostate specimens, on which a total of 11 histologically positive and 22 negative surgical margins were measured. Two select features from 700 to 830 nm were identified as unique to malignant tissue. Cross-validation when performing the predictive model showed that the optical probe predicted positive surgical margins with 85% sensitivity, 86% specificity, 86% accuracy and an AUC of 0.95. Light reflectance spectroscopy can identify positive surgical margins accurately in fresh ex vivo radical prostatectomy specimens. Further study is required to determine whether such analysis may be used in real time to improve surgical decision making and decrease positive surgical margin rates

  5. HER2 testing on core needle biopsy specimens from primary breast cancers: interobserver reproducibility and concordance with surgically resected specimens

    International Nuclear Information System (INIS)

    Tsuda, Hitoshi; Kurosumi, Masafumi; Umemura, Shinobu; Yamamoto, Sohei; Kobayashi, Takayuki; Osamura, Robert Yoshiyuki

    2010-01-01

    Accurate evaluation of human epidermal growth factor receptor type-2 (HER2) status based on core needle biopsy (CNB) specimens is mandatory for identification of patients with primary breast cancer who will benefit from primary systemic therapy with trastuzumab. The aim of the present study was to validate the application of HER2 testing with CNB specimens from primary breast cancers in terms of interobserver reproducibility and comparison with surgically resected specimens. A total of 100 pairs of archival formalin-fixed paraffin-embedded CNB and surgically resected specimens of invasive breast carcinomas were cut into sections. All 100 paired sections were subjected to HER2 testing by immunohistochemistry (IHC) and 27 paired sections were subjected to that by fluorescence in situ hybridization (FISH), the results being evaluated by three and two observers, respectively. Interobserver agreement levels in terms of judgment and the concordance of consensus scores between CNB samples and the corresponding surgically resected specimens were estimated as the percentage agreement and κ statistic. In CNB specimens, the percentage interobserver agreement of HER2 scoring by IHC was 76% (κ = 0.71) for 3 × 3 categories (0-1+ versus 2+ versus 3+) and 90% (κ = 0.80) for 2 × 2 categories (0-2+ versus 3+). These levels were close to the corresponding ones for the surgically resected specimens: 80% (κ = 0.77) for 3 × 3 categories and 92% (κ = 0.88) for 2 × 2 categories. Concordance of consensus for HER2 scores determined by IHC between CNB and the corresponding surgical specimens was 87% (κ = 0.77) for 3 × 3 categories, and 94% (κ = 0.83) for 2 × 2 categories. Among the 13 tumors showing discordance in the mean IHC scores between the CNB and surgical specimens, the results of consensus for FISH results were concordant in 11. The rate of successful FISH analysis and the FISH positivity rate in cases with a HER2 IHC score of 2+ differed among specimens processed at

  6. HER2 testing on core needle biopsy specimens from primary breast cancers: interobserver reproducibility and concordance with surgically resected specimens

    Directory of Open Access Journals (Sweden)

    Yamamoto Sohei

    2010-10-01

    Full Text Available Abstract Background Accurate evaluation of human epidermal growth factor receptor type-2 (HER2 status based on core needle biopsy (CNB specimens is mandatory for identification of patients with primary breast cancer who will benefit from primary systemic therapy with trastuzumab. The aim of the present study was to validate the application of HER2 testing with CNB specimens from primary breast cancers in terms of interobserver reproducibility and comparison with surgically resected specimens. Methods A total of 100 pairs of archival formalin-fixed paraffin-embedded CNB and surgically resected specimens of invasive breast carcinomas were cut into sections. All 100 paired sections were subjected to HER2 testing by immunohistochemistry (IHC and 27 paired sections were subjected to that by fluorescence in situ hybridization (FISH, the results being evaluated by three and two observers, respectively. Interobserver agreement levels in terms of judgment and the concordance of consensus scores between CNB samples and the corresponding surgically resected specimens were estimated as the percentage agreement and κ statistic. Results In CNB specimens, the percentage interobserver agreement of HER2 scoring by IHC was 76% (κ = 0.71 for 3 × 3 categories (0-1+ versus 2+ versus 3+ and 90% (κ = 0.80 for 2 × 2 categories (0-2+ versus 3+. These levels were close to the corresponding ones for the surgically resected specimens: 80% (κ = 0.77 for 3 × 3 categories and 92% (κ = 0.88 for 2 × 2 categories. Concordance of consensus for HER2 scores determined by IHC between CNB and the corresponding surgical specimens was 87% (κ = 0.77 for 3 × 3 categories, and 94% (κ = 0.83 for 2 × 2 categories. Among the 13 tumors showing discordance in the mean IHC scores between the CNB and surgical specimens, the results of consensus for FISH results were concordant in 11. The rate of successful FISH analysis and the FISH positivity rate in cases with a HER2 IHC score of

  7. Vacuum sealing and cooling as methods to preserve surgical specimens

    DEFF Research Database (Denmark)

    Kielsgaard Kristensen, Thomas; Engvad, Birte; Nielsen, Ole

    2011-01-01

    Recently, vacuum-based preservation of surgical specimens has been proposed as a safe alternative to formalin fixation at the surgical theater. The method seems feasible from a practical point of view, but no systematic study has examined the effect of vacuum sealing alone with respect to tissue...

  8. Factors that impact turnaround time of surgical pathology specimens in an academic institution.

    Science.gov (United States)

    Patel, Samip; Smith, Jennifer B; Kurbatova, Ekaterina; Guarner, Jeannette

    2012-09-01

    Turnaround time of laboratory results is important for customer satisfaction. The College of American Pathologists' checklist requires an analytic turnaround time of 2 days or less for most routine cases and lets every hospital define what a routine specimen is. The objective of this study was to analyze which factors impact turnaround time of nonbiopsy surgical pathology specimens. We calculated the turnaround time from receipt to verification of results (adjusted for weekends and holidays) for all nonbiopsy surgical specimens during a 2-week period. Factors studied included tissue type, number of slides per case, decalcification, immunohistochemistry, consultations with other pathologists, and diagnosis. Univariate and multivariate analyses were performed. A total of 713 specimens were analyzed, 551 (77%) were verified within 2 days and 162 (23%) in 3 days or more. Lung, gastrointestinal, breast, and genitourinary specimens showed the highest percentage of cases being signed out in over 3 days. Diagnosis of malignancy (including staging of the neoplasia), consultation with other pathologists, having had a frozen section, and use of immunohistochemical stains were significantly associated with increased turnaround time in univariate analysis. Decalcification was not associated with increased turnaround time. In multivariate analysis, consultation with other pathologists, use of immunohistochemistry, diagnosis of malignancy, and the number of slides studied continued to be significantly associated with prolonged turnaround time. Our findings suggest that diagnosis of malignancy is central to significantly prolonging the turnaround time for surgical pathology specimens, thus institutions that serve cancer centers will have longer turnaround time than those that do not. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Risk Factors Associated with Discordant Ki-67 Levels between Preoperative Biopsy and Postoperative Surgical Specimens in Breast Cancers.

    Directory of Open Access Journals (Sweden)

    Hyung Sun Kim

    Full Text Available The Ki-67 labelling index is significant for the management of breast cancer. However, the concordance of Ki-67 expression between preoperative biopsy and postoperative surgical specimens has not been well evaluated. This study aimed to find the correlation in Ki-67 expression between biopsy and surgical specimens and to determine the clinicopathological risk factors associated with discordant values.Ki-67 levels were immunohistochemically measured using paired biopsy and surgical specimens in 310 breast cancer patients between 2008 and 2013. ΔKi-67 was calculated by postoperative Ki-67 minus preoperative levels. The outliers of ΔKi-67 were defined as [lower quartile of ΔKi-67-1.5 × interquartile range (IQR] or (upper quartile + 1.5 × IQR and were evaluated according to clinicopathological parameters by logistic regression analysis.The median preoperative and postoperative Ki-67 levels were 10 (IQR, 15 and 10 (IQR, 25, respectively. Correlation of Ki-67 levels between the two specimens indicated a moderately positive relationship (coefficient = 0.676. Of 310 patients, 44 (14.2% showed outliers of ΔKi-67 (range, ≤-20 or ≥28. A significant association with poor prognostic factors was found among these patients. Multivariate analysis determined that significant risk factors for outliers of ΔKi-67 were tumor size >1 cm, negative progesterone receptor (PR expression, grade III cancer, and age ≤35 years. Among 171 patients with luminal human epidermal growth factor receptor 2-negative tumors, breast cancer subtype according to preoperative or postoperative Ki-67 levels discordantly changed in 46 (26.9% patients and a significant proportion of patients with discordant cases had ≥1 risk factor.Ki-67 expression showed a substantial concordance between biopsy and surgical specimens. Extremely discordant Ki-67 levels may be associated with aggressive tumor biology. In patients with luminal subtype disease, clinical application of Ki-67

  10. Integration of Value Stream Map and Healthcare Failure Mode and Effect Analysis into Six Sigma Methodology to Improve Process of Surgical Specimen Handling.

    Science.gov (United States)

    Hung, Sheng-Hui; Wang, Pa-Chun; Lin, Hung-Chun; Chen, Hung-Ying; Su, Chao-Ton

    2015-01-01

    Specimen handling is a critical patient safety issue. Problematic handling process, such as misidentification (of patients, surgical site, and specimen counts), specimen loss, or improper specimen preparation can lead to serious patient harms and lawsuits. Value stream map (VSM) is a tool used to find out non-value-added works, enhance the quality, and reduce the cost of the studied process. On the other hand, healthcare failure mode and effect analysis (HFMEA) is now frequently employed to avoid possible medication errors in healthcare process. Both of them have a goal similar to Six Sigma methodology for process improvement. This study proposes a model that integrates VSM and HFMEA into the framework, which mainly consists of define, measure, analyze, improve, and control (DMAIC), of Six Sigma. A Six Sigma project for improving the process of surgical specimen handling in a hospital was conducted to demonstrate the effectiveness of the proposed model.

  11. Integration of Value Stream Map and Healthcare Failure Mode and Effect Analysis into Six Sigma Methodology to Improve Process of Surgical Specimen Handling

    Directory of Open Access Journals (Sweden)

    Sheng-Hui Hung

    2015-01-01

    Full Text Available Specimen handling is a critical patient safety issue. Problematic handling process, such as misidentification (of patients, surgical site, and specimen counts, specimen loss, or improper specimen preparation can lead to serious patient harms and lawsuits. Value stream map (VSM is a tool used to find out non-value-added works, enhance the quality, and reduce the cost of the studied process. On the other hand, healthcare failure mode and effect analysis (HFMEA is now frequently employed to avoid possible medication errors in healthcare process. Both of them have a goal similar to Six Sigma methodology for process improvement. This study proposes a model that integrates VSM and HFMEA into the framework, which mainly consists of define, measure, analyze, improve, and control (DMAIC, of Six Sigma. A Six Sigma project for improving the process of surgical specimen handling in a hospital was conducted to demonstrate the effectiveness of the proposed model.

  12. Processing of fallopian tube, ovary, and endometrial surgical pathology specimens: A survey of U.S. laboratory practices.

    Science.gov (United States)

    Samimi, Goli; Trabert, Britton; Duggan, Máire A; Robinson, Jennifer L; Coa, Kisha I; Waibel, Elizabeth; Garcia, Edna; Minasian, Lori M; Sherman, Mark E

    2018-03-01

    Many high-grade serous carcinomas initiate in fallopian tubes as serous tubal intraepithelial carcinoma (STIC), a microscopic lesion identified with specimen processing according to the Sectioning and Extensive Examination of the Fimbria protocol (SEE-Fim). Given that the tubal origin of these cancers was recently recognized, we conducted a survey of pathology practices to assess processing protocols that are applied to gynecologic surgical pathology specimens in clinical contexts in which finding STIC might have different implications. We distributed a survey electronically to the American Society for Clinical Pathology list-serve to determine practice patterns and compared results between practice types by chi-square (χ2) tests for categorical variables. Free text comments were qualitatively reviewed. Survey responses were received from 159 laboratories (72 academic, 87 non-academic), which reported diverse specimen volumes and percentage of gynecologic samples. Overall, 74.1% of laboratories reported performing SEE-Fim for risk-reducing surgical specimens (82.5% academic versus 65.7% non-academic, p STIC or early cancer precursors. Published by Elsevier Inc.

  13. Recommendations for the reporting of surgically resected specimens of renal cell carcinoma: the Association of Directors of Anatomic and Surgical Pathology.

    Science.gov (United States)

    Higgins, John P; McKenney, Jesse K; Brooks, James D; Argani, Pedram; Epstein, Jonathan I

    2009-04-01

    A checklist based approach to reporting the relevant pathologic details of renal cell carcinoma resection specimens improves the completeness of the report. Karyotypic evaluation of renal neoplasms has refined but also complicated their classification. The number of diagnostic possibilities has increased and the importance of distinguishing different tumor types has been underscored by dramatic variation in prognosis and the development of targeted therapies for specific subtypes. The increasing number of recognized renal neoplasms has implications for handling renal resection specimens. Furthermore, the prognostic significance of other features of renal neoplasms related to grade and stage has been demonstrated. This guideline for the handling of renal resection specimens will focus on problem areas in the evolving practice of diagnosis, grading, and staging of renal neoplasms. The accompanying checklist will serve to ensure that all necessary details of the renal resection specimen are included in the surgical pathology report.

  14. Making mock-FNA smears from fresh surgical pathology specimens to improve smear preparation technique and to create cytohistological correlation series.

    Directory of Open Access Journals (Sweden)

    Tibor Mezei

    Full Text Available Fine needle aspiration (FNA cytology is a well-established diagnostic method based on the microscopic interpretation of often scant cytological material; therefore, experience, good technique and smear quality are equally important in obtaining satisfactory results.We studied the use of fresh surgical pathology specimens for making so-called mock-FNA smears with the potential of cytohistological correlation. Additionally, we studied how this process aids the improvement of preparation technique and smear quality.Cytological aspirates from 32 fresh biopsy specimens from various sites: lung (20, lymph nodes (6, and breast (6 were obtained, all with a clinical diagnosis of tumor. Aspiration was performed from grossly palpable tumors. 25 G needle and Cameco-type syringe holder was used with minimal or no suction.Unfixed surgical specimens provided sufficient cytological material that resulted in good quality smears. After standard processing of specimens into microscopic sections from paraffin embedded tissues, cytohistological case-series were created. No significant alteration was reported in tissue architecture on hematoxylin-eosin stained sections after the aspiration procedure. A gradual, but steady improvement was observed in smear quality just after a few preparations.Our study proved that surgical specimens may be used as a source of cytological material to create cytohistological correlation studies and also to improve FNA cytology skills. The use of very fine gauge needle (25 G, 0,6 mm diameter during the sampling process does not alter tissue architecture therefore the final histopathological diagnosis is not compromised. We conclude that by using fresh surgical specimens useful cytohistological collections can be created both as a teaching resource and as improving experience.

  15. Label-free reflectance hyperspectral imaging for tumor margin assessment: a pilot study on surgical specimens of cancer patients

    Science.gov (United States)

    Fei, Baowei; Lu, Guolan; Wang, Xu; Zhang, Hongzheng; Little, James V.; Patel, Mihir R.; Griffith, Christopher C.; El-Diery, Mark W.; Chen, Amy Y.

    2017-08-01

    A label-free, hyperspectral imaging (HSI) approach has been proposed for tumor margin assessment. HSI data, i.e., hypercube (x,y,λ), consist of a series of high-resolution images of the same field of view that are acquired at different wavelengths. Every pixel on an HSI image has an optical spectrum. In this pilot clinical study, a pipeline of a machine-learning-based quantification method for HSI data was implemented and evaluated in patient specimens. Spectral features from HSI data were used for the classification of cancer and normal tissue. Surgical tissue specimens were collected from 16 human patients who underwent head and neck (H&N) cancer surgery. HSI, autofluorescence images, and fluorescence images with 2-deoxy-2-[(7-nitro-2,1,3-benzoxadiazol-4-yl)amino]-D-glucose (2-NBDG) and proflavine were acquired from each specimen. Digitized histologic slides were examined by an H&N pathologist. The HSI and classification method were able to distinguish between cancer and normal tissue from the oral cavity with an average accuracy of 90%±8%, sensitivity of 89%±9%, and specificity of 91%±6%. For tissue specimens from the thyroid, the method achieved an average accuracy of 94%±6%, sensitivity of 94%±6%, and specificity of 95%±6%. HSI outperformed autofluorescence imaging or fluorescence imaging with vital dye (2-NBDG or proflavine). This study demonstrated the feasibility of label-free, HSI for tumor margin assessment in surgical tissue specimens of H&N cancer patients. Further development of the HSI technology is warranted for its application in image-guided surgery.

  16. Microvascular injury of the peribiliary plexus associated with transarterial chemoembolization: a study of surgical specimens

    Energy Technology Data Exchange (ETDEWEB)

    Park, Won Kyu; Bae, Young Kyung; Hwang, Tae Yoon; Cho, Jae Ho; Chang, Jay Chun; Kim, Jae Woon; Jang, Han Won [College of Medicine, Yeungnam University, Daegu (Korea, Republic of)

    2006-11-15

    We attempted to evaluate the relationship between transarteiral chemoembolization (TACE) and injury to the peribiliary plexus by evaluating the number of microvessels in peribiliary plexus of surgical specimen. Surgical specimens were obtained from 78 hepatocellular carcinoma patients and 22 patients with liver metastases. They were divided into 4 groups (Group 1; hepatocellular carcinoma without TACE [n=30], Group 2; hepatocellular carcinoma receiving preoperative TACE once [n=37], Group 3; hepatocellular carcinoma receiving preoperative TACE more than two times [n=11] and Group 4; metastatic carcinoma of the liver patients without a history of liver disease [n=22]). Immunohistochemical staining for factor VIII-related antigen was performed in all the specimens and the number of microvessels in the inner capillary layer and the outer venous layer of the bile duct (> 200 {mu} m in diameter) was counted. The mean numbers of microvessels in the inner capillary layer were 4.50, 4.08, 1.64 and 2.05, and those in the outer venous layer were 25.23, 20.00, 18.36 and 12.32 for the 4 groups, respectively. The number of microvessels in group 4 was statistically fewer than that of group 1 ({rho} < 0.01). In the hepatocellular carcinoma patients, the number of microvessels was decreased as the number of TACE sessions was increased. The number of microvessels in the peribiliary plexus is increased in chronic liver disease patients. It may be from the increased portal pressure and flow stagnation in the sinusoidal and portal venules. TACE can have an effect on microvascular injury of the peibiliary plexus, and this can be a cause of bile duct necrosis and biloma.

  17. Evaluation of conventional, dynamic contrast enhanced and diffusion weighted MRI for quantitative Crohn's disease assessment with histopathology of surgical specimens

    NARCIS (Netherlands)

    Tielbeek, Jeroen A. W.; Ziech, Manon L. W.; Li, Zhang; Lavini, Cristina; Bipat, Shandra; Bemelman, Willem A.; Roelofs, Joris J. T. H.; Ponsioen, Cyriel Y.; Vos, Frans M.; Stoker, Jaap

    2014-01-01

    To prospectively compare conventional MRI sequences, dynamic contrast enhanced (DCE) MRI and diffusion weighted imaging (DWI) with histopathology of surgical specimens in Crohn's disease. 3-T MR enterography was performed in consecutive Crohn's disease patients scheduled for surgery within 4 weeks.

  18. Recommendations for processing cardiovascular surgical pathology specimens: a consensus statement from the Standards and Definitions Committee of the Society for Cardiovascular Pathology and the Association for European Cardiovascular Pathology

    NARCIS (Netherlands)

    Stone, James R.; Basso, Cristina; Baandrup, Ulrik T.; Bruneval, Patrick; Butany, Jagdish; Gallagher, Patrick J.; Halushka, Marc K.; Miller, Dylan V.; Padera, Robert F.; Radio, Stanley J.; Sheppard, Mary N.; Suvarna, Kim; Tan, Carmela D.; Thiene, Gaetano; van der Wal, Allard C.; Veinot, John P.

    2012-01-01

    With the advent of molecular subclassification of diseases, much consideration should be given to the proper processing of cardiovascular surgical pathology specimens to maximize patient care. Such specimens include endomyocardial biopsies, cardiac myectomy specimens, cardiac apical core segments,

  19. Strain Measurement System Developed for Biaxially Loaded Cruciform Specimens

    Science.gov (United States)

    Krause, David L.

    2000-01-01

    A new extensometer system developed at the NASA Glenn Research Center at Lewis Field measures test area strains along two orthogonal axes in flat cruciform specimens. This system incorporates standard axial contact extensometers to provide a cost-effective high-precision instrument. The device was validated for use by extensive testing of a stainless steel specimen, with specimen temperatures ranging from room temperature to 1100 F. In-plane loading conditions included several static biaxial load ratios, plus cyclic loadings of various waveform shapes, frequencies, magnitudes, and durations. The extensometer system measurements were compared with strain gauge data at room temperature and with calculated strain values for elevated-temperature measurements. All testing was performed in house in Glenn's Benchmark Test Facility in-plane biaxial load frame.

  20. Method and Apparatus for Measuring Thermal Conductivity of Small, Highly Insulating Specimens

    Science.gov (United States)

    Miller, Robert A (Inventor); Kuczmarski, Maria A (Inventor)

    2013-01-01

    A method and apparatus for the measurement of thermal conductivity combines the following capabilities: 1) measurements of very small specimens; 2) measurements of specimens with thermal conductivity on the same order of that as air; and, 3) the ability to use air as a reference material. Care is taken to ensure that the heat flow through the test specimen is essentially one-dimensional. No attempt is made to use heated guards to minimize the flow of heat from the hot plate to the surroundings. Results indicate that since large correction factors must be applied to account for guard imperfections when specimen dimensions are small, simply measuring and correcting for heat from the heater disc that does not flow into the specimen is preferable.

  1. Comparison of measurement results between cervical pedicle specimens and CT images

    International Nuclear Information System (INIS)

    Zhang Guangjian; Li Hua; Liu Haiyan; Gao Zhenping

    2011-01-01

    Objective: To compare the difference between the measurement results of the cervical pedicle specimens and CT image, and provide the basis for clinical cervical screw internal fixation operation. Methods: Twenty-seven Chinese adult cadaver cervical specimens including C3 to C7 vertebrae were measured by a digital calipers and CT image, containing pedicle height (PH, PH'), pedicle width(PW, PW'), total pedicle length (TL, TL') and two pedicle lengths(PL1, PL2; PL1', PL2'). The results of specimens and CT image were compared. Results: Different cervical vertebra in the same side of specimens or CT images, PW (PW'): C3, C4< C5, C6 (P<0.05), C5, C6< C7 (P<0.01); PH (PH'): there were no significant differences; TL, PL1, PL2 (TL', PL1', PL2'): there were no marked differences. In the same cervical vertebra of the specimens or CT images, PW (PW')< PH (PH') (P<0.01), PL1 (PL1') < PL2 (PL2') (P<0.01). Conclusion: The results of measurement by CT images are not markedly different from that of specimens. CT image measurement is available before cervical screw internal fixation operation. (authors)

  2. Measurement of deformation field in CT specimen using laser speckle

    International Nuclear Information System (INIS)

    Jeon, Moon Chang; Kang, Ki Ju

    2001-01-01

    To obtain A 2 experimentally in the J-A 2 theory, deformation field on the lateral surface of a CT specimen was to be determined using laser speckle method. The crack growth was measured using direct current potential drop method and most procedure of experimental and data reduction was performed according to ASTM Standard E1737-96. Laser speckle images during crack propagation were monitored by two CCD cameras to cancel the effect of rotation and translation of the specimen. An algorithm to pursue displacement of a point from each image was developed and successfully used to measure A 2 continuously as the crack tip was propagated. The effects of specimen thickness on J-R curve and A 2 were explored

  3. Use of miniature tensile specimen and video extensometer for measurement of mechanical properties

    International Nuclear Information System (INIS)

    Kumar, Kundan; Pooleery, Arun; Madhusoodanan, K.

    2014-08-01

    Miniaturisation of the tensile test specimen below the sub-size level poses various challenges, such as conformity of specimen to various acceptance criteria as per standard test specimen, aspect ratio, minimum number of grains required in a gauge cross-section, fabrication for uniformity in metrological values, etc. Apart from these, measurement of strain over a very limited available space on the test specimen is another practical challenge. Despite these limitations, miniature specimen testing is increasingly being used worldwide these days. The driving forces behind increasing use of miniature test techniques are new material development, assuring fitness of component after in-service-inspection, low dose of radiation exposure due to smaller dimensions of test specimens etc. However, the evaluation of mechanical properties from a miniature tensile test has a greater advantage over the other miniature novel test techniques, such as small punch test, ABI, miniature fatigue and impact tests etc., as it is a direct method of measurement of mechanical properties. This report covers various aspects of miniature tensile test methodologies, which include geometrical design of specimen having gauge length of 3-5 mm, fabrication, development of special fixtures for gripping the test specimens, and use of optical method for strain measurement. The geometrical design of the specimen and its behaviour over application of tensile load has been established using FEM analysis. A good agreement between conventional and miniature test results exemplifies the potential of the miniature tensile test technique. (author)

  4. Echosonography and surgical therapy of facial skin tumors

    Directory of Open Access Journals (Sweden)

    Pešić Zoran U.

    2002-01-01

    Full Text Available In the second half of the 20 century, echosonography has been used in many medical specialties. In 1992 and 1993 highfrequencies echosonography was used in the examination of irritant and allergic skin lesions in order to examine the effects of different therapeuthical agents on the skin lesions [1-4]. Hoffmann used highfrequencies echosonography in the examination of healing of skin lesions [3]. By their incidence skin tumors are the largest group of newly discovered tumors, and their usual location is on the face [5-7]. By clinical examination it is not possible to precisely determine the depth of tumor border; therefore, the radically performed surgical excision is the only correct surgical treatment. The aim of this study was to estimate the results of preoperatively performed high frequencies echosonography in order to reduce the number of incorrectly performed surgical excisions of skin tumors. The group was composed of 40 patients with 45 tumors, who first underwent echosonographic diagnostic procedure (20 MHz, Hadsund electronic, Hadsund Technology, Denmark and then surgical excision; patients in control group (45 patients with 45 tumors were only subjected to surgical excision. Excised tumors were then pathohistologically analyzed, and measurements of tumor depth progression were performed. Margins of pathohistological specimen were controlled for the presence of tumor cells. Results of measurements of tumor depth obtained by echosonography and pathohistological measurements were compared. By Jate's modification of c2 test results regarding correct and incorrect surgical excision in patients and control group were compared. By linear regression analysis results of tumor depth obtained by echosonographic and pathohistologic examinations were compared. Hypoechogen zone echosonographic results were used like criteria for tumor expansion. Results of tumor depth measurements are presented in Table 1. Linear regression analysis showed (R = 0

  5. Measurements and Counts for Notacanthidae Specimens

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Taxonomic data were collected for specimens of deep-sea spiny eels (Notacanthidae) from the Hawaiian Ridge by Bruce C. Mundy. Specimens were collected off the north...

  6. Clinical evaluation of a mobile digital specimen radiography system for intraoperative specimen verification.

    Science.gov (United States)

    Wang, Yingbing; Ebuoma, Lilian; Saksena, Mansi; Liu, Bob; Specht, Michelle; Rafferty, Elizabeth

    2014-08-01

    Use of mobile digital specimen radiography systems expedites intraoperative verification of excised breast specimens. The purpose of this study was to evaluate the performance of a such a system for verifying targets. A retrospective review included 100 consecutive pairs of breast specimen radiographs. Specimens were imaged in the operating room with a mobile digital specimen radiography system and then with a conventional digital mammography system in the radiology department. Two expert reviewers independently scored each image for image quality on a 3-point scale and confidence in target visualization on a 5-point scale. A target was considered confidently verified only if both reviewers declared the target to be confidently detected. The 100 specimens contained a total of 174 targets, including 85 clips (49%), 53 calcifications (30%), 35 masses (20%), and one architectural distortion (1%). Although a significantly higher percentage of mobile digital specimen radiographs were considered poor quality by at least one reviewer (25%) compared with conventional digital mammograms (1%), 169 targets (97%), were confidently verified with mobile specimen radiography; 172 targets (98%) were verified with conventional digital mammography. Three faint masses were not confidently verified with mobile specimen radiography, and conventional digital mammography was needed for confirmation. One faint mass and one architectural distortion were not confidently verified with either method. Mobile digital specimen radiography allows high diagnostic confidence for verification of target excision in breast specimens across target types, despite lower image quality. Substituting this modality for conventional digital mammography can eliminate delays associated with specimen transport, potentially decreasing surgical duration and increasing operating room throughput.

  7. 3D geometry measurement of hot cylindric specimen using structured light

    Science.gov (United States)

    Quentin, Lorenz; Beermann, Rüdiger; Pösch, Andreas; Reithmeier, Eduard; Kästner, Markus

    2017-06-01

    We present a fringe projection system to measure glowing hot hybrid components in between production processes. For this a high power green light projector, based on TI DLP technology, is used to create the highest possible contrast between fringes on the red glowing specimen. It has a resolution of 1140 x 912 pixels with a maximum frame rate of 120 images per second for fast measurement. We use a green bandpass filter (525 nm) on the camera lens to block unwanted incoming radiation from the specimen caused by self-emission. Commercial measurement standards are not calibrated for temperatures other than 20° C, so they cannot be used to validate measurement data at the required temperatures of up to 1000°C since thermal expansion invalidates the geometry specification from the calibration data sheet. In our first development we use a uniformly heated pipe made of stainless steel as a dummy specimen to examine the measured geometry data. A pyrometer measures the temperature of the pipe so the expansion can be easily calculated using the thermal expansion coefficient. Different impact and triangulation angles are investigated to identify the effects of hot ambient air on the measurement. The impact of the induced refractive index gradient is examined to check the need for pre-processing steps in the measurement routine.

  8. MR evaluation of postmenopausal ovarian size. Comparison with surgical specimen

    International Nuclear Information System (INIS)

    Joja, Ikuo; Ishida, Kana; Matsushita, Toshi; Mimura, Seiichi; Yamaguchi, Takuya; Akagi, Noriaki; Miyagi, Yasunari; Hara, Takeshi; Kanazawa, Susumu

    2008-01-01

    We investigated ovarian size after menopause using magnetic resonance (MR) imaging and gross specimens obtained from patients with uterine cancer after menopause in whom normal ovaries were confirmed at the time of surgery. The relationships between size of ovarian long axis and age, the number of years since menopause, and age at menopause were statistically evaluated for 130 ovaries observed in short-axis T 2 -weighted MR images of the uterine corpus and in 147 ovarian gross specimens. No significant relationships were found between size of ovarian long axis and these 3 factors. When the sizes of the ovaries in MR images were compared with those in gross specimens, the latter were larger, with a statistically significant difference. Similarly, when the sizes of the ovaries observed or not observed in MR images were compared in gross specimens, the former were larger, with a statistically significant difference. These results indicate that the size of the ovarian long axis observed in MR images does not accurately reflect the true size of the long axis, but ovarian size strongly affects visualization of the ovaries in MR images after menopause. In addition, these results indicate that there are no significant relationships between ovarian size after menopause and age, the number of years since menopause, or age at menopause. (author)

  9. Role of specimen US for predicting resection margin status in breast conserving therapy.

    Science.gov (United States)

    Moschetta, M; Telegrafo, M; Introna, T; Coi, L; Rella, L; Ranieri, V; Cirili, A; Stabile Ianora, A A; Angelelli, G

    2015-01-01

    To assess the diagnostic accuracy of specimen ultrasound (US) for predicting resection margin status in women undergoing breast conserving therapy for US-detected cancer, having the histological findings as the reference standard. A total of 132 consecutive patients (age range, 34-87 years; mean, 51 years) underwent breast-conserving surgery for US-detected invasive breast cancer. All surgical specimens underwent US examination. The presence of lesion within the specimen and its distance from the specimen margins were assessed considering a threshold distance between the lesion and specimen margins of 10 mm. US findings were then compared with the pathological ones and specimen US. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) for predicting histological margin status were evaluated, having the histological findings as the reference standard. The histological examination detected invasive ductal carcinoma in 96/132 (73%) cases, invasive lobular carcinoma in 32/132 (24%), mucinous carcinoma in 4/132 (3%). The pathological margin analysis revealed 96/132 (73%) negative margins and 36 (27%) close/positive margins. US examination detected all 132 breast lesions within the surgical specimens. 110 (83%) negative margins and 22 (17%) positive margins were found on US. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 44%, 94%, 80%, 73% and 82%, respectively, were found for specimen US. Specimen US represents a time and cost saving imaging tool for evaluating the presence of US detected-breast lesion within surgical specimen and for predicting the histological margin status.

  10. Towards real-time metabolic profiling of a biopsy specimen during a surgical operation by 1H high resolution magic angle spinning nuclear magnetic resonance: a case report

    Directory of Open Access Journals (Sweden)

    Piotto Martial

    2012-01-01

    Full Text Available Abstract Introduction Providing information on cancerous tissue samples during a surgical operation can help surgeons delineate the limits of a tumoral invasion more reliably. Here, we describe the use of metabolic profiling of a colon biopsy specimen by high resolution magic angle spinning nuclear magnetic resonance spectroscopy to evaluate tumoral invasion during a simulated surgical operation. Case presentation Biopsy specimens (n = 9 originating from the excised right colon of a 66-year-old Caucasian women with an adenocarcinoma were automatically analyzed using a previously built statistical model. Conclusions Metabolic profiling results were in full agreement with those of a histopathological analysis. The time-response of the technique is sufficiently fast for it to be used effectively during a real operation (17 min/sample. Metabolic profiling has the potential to become a method to rapidly characterize cancerous biopsies in the operation theater.

  11. Surgical specimen handover from the operating theatre to laboratory-Can we improve patient safety by learning from aviation and other high-risk organisations?

    Science.gov (United States)

    Brennan, Peter A; Brands, Marieke T; Caldwell, Lucy; Fonseca, Felipe Paiva; Turley, Nic; Foley, Susie; Rahimi, Siavash

    2018-02-01

    Essential communication between healthcare staff is considered one of the key requirements for both safety and quality care when patients are handed over from one clinical area to other. This is particularly important in environments such as the operating theatre and intensive care where mistakes can be devastating. Health care has learned from other high-risk organisations (HRO) such as aviation where the use of checklists and human factors awareness has virtually eliminated human error and mistakes. To our knowledge, little has been published around ways to improve pathology specimen handover following surgery, with pathology request forms often conveying the bare minimum of information to assist the laboratory staff. Furthermore, the request form might not warn staff about potential hazards. In this article, we provide a brief summary of the factors involved in human error and introduce a novel checklist that can be readily completed at the same time as the routine pathology request form. This additional measure enhances safety, can help to reduce processing and mislabelling errors and provides essential information in a structured way assisting both laboratory staff and pathologists when handling head and neck surgical specimens. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Fracture toughness measurements with subsize disk compact specimens

    International Nuclear Information System (INIS)

    Alexander, D.J.

    1992-01-01

    Special fixtures and test methods are necessary to facilitate the fracture toughness testing of small disk compact specimens of irradiated candidate materials for first-wall fusion applications. New methods have been developed for both the unloading compliance and potential drop techniques of monitoring crack growth. Provisions have been made to allow the necessary probes and instrumentation to be installed remotely using manipulators for testing of irradiated specimens in a hot cell. Laboratory trials showed that both unloading compliance and potential drop gave useful results. Both techniques gave similar data, and predicted the final crack extension within allowable limits. The results from the small disk compact specimens were similar to results from conventional compact specimen 12.7 mm thick. However, the slopes of the J-R curves from the larger specimens were lower, suggesting that the smaller disk compact specimens may have lost some constraint due to their size. The testing shows that it should be possible to generate useful J-R curve fracture toughness data from the small disk compact specimens

  13. Fracture toughness measurements with subsize disk compact specimens

    International Nuclear Information System (INIS)

    Alexander, D.J.

    1992-01-01

    Special fixtures and test methods have been developed for testing small disk compact specimens (12.5 mm diam by 4.6 mm thick). Both unloading compliance and potential drop methods have been used to monitor crack extension during the J-integral resistance (J-R) curve testing. Provisions have been made to allow the necessary probes and instrumentation to be installed remotely using manipulators for testing of irradiated specimens in a hat cell. Laboratory trials showed that both unloading compliance and potential drop gave useful results. Both techniques gave similar data, and predicted the final crack extension within allowable limits. The results from the small disk compact specimens were similar to results from conventional compact specimens 12.7-mm thick. However, the slopes of the J-R curves from the larger specimens were lower, suggesting that the smaller disk compact specimens may have lost some constraint due to their size. The testing shows that it should be possible to generate useful J-R curve fracture toughness data from the small disk compact specimens

  14. Survival curves after X-ray and heat treatments for melanoma cells derived directly from surgical specimens of tumours in man

    International Nuclear Information System (INIS)

    Rofstad, E.K.; Wahl, A.; Tveit, K.M.; Monge, O.R.; Brustad, T.

    1985-01-01

    X-ray and heat survival curves were established for melanoma cells derived directly from surgical specimens of tumours in man by using the Courtenay soft agar colony assay. The plating efficiency for 11 of the 14 melanomas studied was sufficiently high (PE = 0.3-58%) to measure cell survival over at least two decades. Experiments repeated with cells stored in liquid nitrogen showed that the survival assay gave highly reproducible results. The melanomas exhibited individual and characteristic survival curves whether exposed to radiation or heat (43.5 0 C). The D 0 -values were in the ranges 0.63-1.66 Gy (X-rays) and 33-58 min (heat). The survival curves were similar to those reported previously for human melanoma xenografts. The radiation sensitivity of the cells was not correlated to the heat sensitivity. Since the melanomas appeared to be very heterogeneous in radiation response in vitro as melanomas are known to be clinically, it is suggested that melanomas may be suitable for prospective studies aimed at establishing whether clinical radioreponsiveness somehow is related to in vitro survival curve parameters. (orig.)

  15. Development of stress relaxation measurement by a small size C-ring specimen method

    International Nuclear Information System (INIS)

    Shimanuki, Shizuka; Nakata, Kiyotomo; Kasahara, Shigeki; Kuniya, Jiro

    2002-01-01

    A stress relaxation measurement method has been developed by using C-ring specimens, and a specimen size effect has been evaluated taking radiation-induced stress relaxation into consideration. C-ring specimens were stressed by forcing a wedge in the gap. Giving an appropriate eccentric configuration in the half of the ring opposite the gap, the stress gradient along the circumference was eliminated in the section and the stress level could be varied by changing the gap spacing. The validity of the C-ring test method was confirmed by thermally stress relaxation experiments at annealing temperatures from 300 to 600degC for 1 min to 200 h in carbon steel: considerable stress relaxation could be measured for all levels of applied stress even at relatively low annealing temperatures. The relaxation results obtained from the C-ring test were in good agreement with those from a uniaxial tensile stress relaxation test. The smaller C-ring specimen with about 40 mm diameter, which is required for radiation-induced stress relaxation test, also showed adequate accuracy on stress relaxation at 600 to 830degC in stainless steel, compared with the large size C-ring specimen test. (author)

  16. Lymph node retrieval in abdominoperineal surgical specimen is radiation time-dependent

    Directory of Open Access Journals (Sweden)

    Allal Abdelkarim S

    2006-06-01

    Full Text Available Abstract Background A low yield of lymph nodes (LN in abdominoperineal resection (APR specimen has been associated with preoperative radiation therapy (XRT in population-based studies, which may preclude adequate staging of anorectal carcinomas. We hypothesized that the number of LN retrieved in APR specimen was correlated with the dose and the timing of pelvic irradiation. Patients and methods We performed a retrospective study of 102 patients who underwent APR in a single institution between 1980 and 2004. Pathological reports were reviewed and the number of lymph nodes retrieved in APR specimens was correlated with: 1 Preoperative radiation; 2 Dose of pelvic irradiation; and 3 Time interval between the end of XRT and surgery. Results There were 61 men and 41 women, with a median age of 66 (range 25–89 years. There were 12 patients operated for squamous cell carcinoma of the anal canal (SCCA and 90 for rectal cancer. 83% and 46% of patients with anal and rectal cancer respectively underwent radical/neoadjuvant radiotherapy. The mean ± SD number of LN in APR specimen was 9.2 ± 5.9. The mean number of LN in APR specimen was significantly lower in patients who underwent preoperative XRT (8 ± 5.5 vs. 10.5 ± 6.1, Mann-Whitney U test, p = 0.02. The mean number of LN was not significantly different after XRT in patients with SCCA than in patients with rectal cancer (6.2 ± 5.3 vs. 7.8 ± 5.3, p = 0.33. Finally, there was an inverse correlation between the yield of LN and the time elapsed between XRT and surgery (linear regression coefficient r = -0.32, p = 0.03. Conclusion Our data indicate that: 1 radiation therapy affects the yield of LN retrieval in APR specimen; 2 this impact is time-dependent. These findings have important implications with regard to anatomic-pathological staging of anal and rectal cancers and subsequent decision-making regarding adjuvant chemotherapy.

  17. A Histomorphological Pattern Analysis of Pulmonary Tuberculosis in Lung Autopsy and Surgically Resected Specimens

    Directory of Open Access Journals (Sweden)

    Mamta Gupta

    2016-01-01

    Full Text Available Background. Tuberculosis (TB is a major cause of morbidity and mortality globally. Many cases are diagnosed on autopsy and a subset of patients may require surgical intervention either due to the complication or sequelae of TB. Materials and Methods. 40 cases of resected lung specimens following surgery or autopsy in which a diagnosis of pulmonary tuberculosis was made were included. Histopathological pattern analysis of pulmonary tuberculosis along with associated nonneoplastic changes and identification of Mycobacterium tuberculosis bacilli was done. Results. The mean age of diagnosis was 41 years with male predominance (92.5%. Tuberculosis was suspected in only 12.1% of cases before death. Seven cases were operated upon due to associated complications or suspicion of malignancy. Tubercular consolidation was the most frequent pattern followed by miliary tuberculosis. The presence of necrotizing granulomas was seen in 33 cases (82.5%. Acid fast bacilli were seen in 57.5% cases on Ziehl-Neelsen stain. Conclusion. Histopathology remains one of the most important methods for diagnosing tuberculosis, especially in TB prevalent areas. It should be considered in the differential diagnosis of all respiratory diseases because of its varied clinical presentations and manifestations.

  18. Development of high time-resolution laser flash equipment for thermal diffusivity measurements using miniature-size specimens

    International Nuclear Information System (INIS)

    Shikama, Tatsuo; Namba, Chusei; Kosuda, Michinori; Maeda, Yukio.

    1994-01-01

    For measurements of thermal diffusivity of miniature-size specimens heavily irradiated by neutrons, a new Q-switched laser-flash instrument was developed. In the present instrument the time-resolution was improved to 0.1 ms by using a laser-pulse width of 25 ns. The realization of high time-resolution made it possible to measure the thermal diffusivity of thin specimens. It is expected that copper of 0.7 mm thick, and SUS 304 of 0.1 mm could be used for the measurements. In case of ATJ graphite, 0.5 mm thick specimen could be used for the reliable measurement in the temperature range of 300-1300 K. (author)

  19. Model Equation for Acoustic Nonlinear Measurement of Dispersive Specimens at High Frequency

    Science.gov (United States)

    Zhang, Dong; Kushibiki, Junichi; Zou, Wei

    2006-10-01

    We present a theoretical model for acoustic nonlinearity measurement of dispersive specimens at high frequency. The nonlinear Khokhlov-Zabolotskaya-Kuznetsov (KZK) equation governs the nonlinear propagation in the SiO2/specimen/SiO2 multi-layer medium. The dispersion effect is considered in a special manner by introducing the frequency-dependant sound velocity in the KZK equation. Simple analytic solutions are derived by applying the superposition technique of Gaussian beams. The solutions are used to correct the diffraction and dispersion effects in the measurement of acoustic nonlinearity of cottonseed oil in the frequency range of 33-96 MHz. Regarding two different ultrasonic devices, the accuracies of the measurements are improved to ±2.0% and ±1.3% in comparison with ±9.8% and ±2.9% obtained from the previous plane wave model.

  20. Epidemiologic evaluation ABCC and Nagasaki University School of Medicine autopsies and ABCC surgical specimens: Nagasaki 1950-59

    Energy Technology Data Exchange (ETDEWEB)

    Samther, T G; Hrubec, Zdenek; Brown, W J; Thomas, G D

    1962-08-22

    This epidemiologic evaluation covered autopsies performed at ABCC Nagasaki and at the Nagasaki University School of Medicine, as well as surgical pathology specimens examined at ABCC Nagasaki during 1950-59. The material was related to the ABCC Master Sample population. Bias was demonstrated with respect to symptom status, exposure, age, death certificate diagnosis, male occupations, and history of previous medical examinations at ABCC. In addition the ABCC autopsy series was found to be biased with regard to sex. Comparison with data from Hiroshima indicated similar bias which is possibly more pronounced in Hiroshima. On the basis of these findings, it was concluded that at this time the material is not suitable for broad epidemiologic studies of clinically manifest disease. The material, however, does lend itself to a number of studies of clinically occult disease and other problems which were discussed. 19 references, 32 tables.

  1. Role of specimen size upon the measured toughness of cellular solids

    International Nuclear Information System (INIS)

    Christodoulou, I; Tan, P J

    2013-01-01

    It is well known that the mechanical properties of cellular solids depend critically upon the specimen size and that a 'sufficiently' large test specimen is needed to obtain representative bulk values. Notwithstanding, the fracture toughness of cellular solids is still measured experimentally based on standards, such as the ASTM E399 and E813, developed for solid materials that do not possess an intermediate, 'cell-level' length scale. Experimental data in the literature appears to show that the toughness of stochastic 3D foams is, also, size-dependent. This paper presents the results of a detailed finite element (FE) study that will quantify, and identify the physical origin of, the size-dependent effect. Three-point bending of a single-edge notched (or SEN(B)) specimen, with a 2D Voronoi micro-architecture, is modelled numerically to obtain estimates of fracture toughness which are compared to those obtained with a 'boundary-layer' analysis

  2. Innovations in macroscopic evaluation of pancreatic specimens and radiologic correlation

    Directory of Open Access Journals (Sweden)

    Charikleia Triantopoulou

    2016-01-01

    Full Text Available The purpose of this study was to evaluate the feasibility of a novel dissection technique of surgical specimens in different cases of pancreatic tumors and provide a radiologic pathologic correlation. In our hospital, that is a referral center for pancreatic diseases, the macroscopic evaluation of the pancreatectomy specimens is performed by the pathologists using the axial slicing technique (instead of the traditional procedure with longitudinal opening of the main pancreatic and/or common bile duct and slicing along the plane defined by both ducts. The specimen is sliced in an axial plane that is perpendicular to the longitudinal axis of the descending duodenum. The procedure results in a large number of thin slices (3–4 mm. This plane is identical to that of CT or MRI and correlation between pathology and imaging is straightforward. We studied 70 cases of suspected different solid and cystic pancreatic tumors and we correlated the tumor size and location, the structure—consistency (areas of necrosis—hemorrhage—fibrosis—inflammation, the degree of vessels’ infiltration, the size of pancreatic and common bile duct and the distance from resection margins. Missed findings by imaging or pitfalls were recorded and we tried to explain all discrepancies between radiology evaluation and the histopathological findings. Radiologic-pathologic correlation is extremely important, adding crucial information on imaging limitations and enabling quality assessment of surgical specimens. The deep knowledge of different pancreatic tumors’ consistency and way of extension helps to improve radiologists’ diagnostic accuracy and minimize the radiological-surgical mismatching, preventing patients from unnecessary surgery.

  3. Rapid virtual hematoxylin and eosin histology of breast tissue specimens using a compact fluorescence nonlinear microscope.

    Science.gov (United States)

    Cahill, Lucas C; Giacomelli, Michael G; Yoshitake, Tadayuki; Vardeh, Hilde; Faulkner-Jones, Beverly E; Connolly, James L; Sun, Chi-Kuang; Fujimoto, James G

    2018-01-01

    Up to 40% of patients undergoing breast conserving surgery for breast cancer require repeat surgeries due to close to or positive margins. The lengthy processing required for evaluating surgical margins by standard paraffin-embedded histology precludes its use during surgery and therefore, technologies for rapid evaluation of surgical pathology could improve the treatment of breast cancer by reducing the number of surgeries required. We demonstrate real-time histological evaluation of breast cancer surgical specimens by staining specimens with acridine orange (AO) and sulforhodamine 101 (SR101) analogously to hematoxylin and eosin (H&E) and then imaging the specimens with fluorescence nonlinear microscopy (NLM) using a compact femtosecond fiber laser. A video-rate computational light absorption model was used to produce realistic virtual H&E images of tissue in real time and in three dimensions. NLM imaging could be performed to depths of 100 μm below the tissue surface, which is important since many surgical specimens require subsurface evaluation due to contamination artifacts on the tissue surface from electrocautery, surgical ink, or debris from specimen handling. We validate this method by expert review of NLM images compared to formalin-fixed, paraffin-embedded (FFPE) H&E histology. Diagnostically important features such as normal terminal ductal lobular units, fibrous and adipose stromal parenchyma, inflammation, invasive carcinoma, and in situ lobular and ductal carcinoma were present in NLM images associated with pathologies identified on standard FFPE H&E histology. We demonstrate that AO and SR101 were extracted to undetectable levels after FFPE processing and fluorescence in situ hybridization (FISH) HER2 amplification status was unaffected by the NLM imaging protocol. This method potentially enables cost-effective, real-time histological guidance of surgical resections.

  4. Irradiation temperature measurement of the reactor pressure vessel surveillance specimen in the programmes of radiation degradation monitoring

    International Nuclear Information System (INIS)

    Kupca, L.; Stanc, S.; Simor, S.

    2001-01-01

    The information's about the special system of irradiation temperature measurement, used for reactor pressure vessel surveillance specimen, which are placed in reactor thermal shielding canals are presented in the paper. The system was designed and realized in the frame of Extended Surveillance Specimen Programme for NPP V-2 Jaslovske Bohunice and Modern Surveillance Specimen Programme for NPP Mochovce. Base design aspects, technical parameters of realization and results of measurement on the two units in Bohunice and Mochovce NPPs are presented too. (Authors)

  5. Epithelium percentage estimation facilitates epithelial quantitative protein measurement in tissue specimens.

    Science.gov (United States)

    Chen, Jing; Toghi Eshghi, Shadi; Bova, George Steven; Li, Qing Kay; Li, Xingde; Zhang, Hui

    2013-12-01

    The rapid advancement of high-throughput tools for quantitative measurement of proteins has demonstrated the potential for the identification of proteins associated with cancer. However, the quantitative results on cancer tissue specimens are usually confounded by tissue heterogeneity, e.g. regions with cancer usually have significantly higher epithelium content yet lower stromal content. It is therefore necessary to develop a tool to facilitate the interpretation of the results of protein measurements in tissue specimens. Epithelial cell adhesion molecule (EpCAM) and cathepsin L (CTSL) are two epithelial proteins whose expressions in normal and tumorous prostate tissues were confirmed by measuring staining intensity with immunohistochemical staining (IHC). The expressions of these proteins were measured by ELISA in protein extracts from OCT embedded frozen prostate tissues. To eliminate the influence of tissue heterogeneity on epithelial protein quantification measured by ELISA, a color-based segmentation method was developed in-house for estimation of epithelium content using H&E histology slides from the same prostate tissues and the estimated epithelium percentage was used to normalize the ELISA results. The epithelium contents of the same slides were also estimated by a pathologist and used to normalize the ELISA results. The computer based results were compared with the pathologist's reading. We found that both EpCAM and CTSL levels, measured by ELISA assays itself, were greatly affected by epithelium content in the tissue specimens. Without adjusting for epithelium percentage, both EpCAM and CTSL levels appeared significantly higher in tumor tissues than normal tissues with a p value less than 0.001. However, after normalization by the epithelium percentage, ELISA measurements of both EpCAM and CTSL were in agreement with IHC staining results, showing a significant increase only in EpCAM with no difference in CTSL expression in cancer tissues. These results

  6. Evaluation of adherence to measures for the prevention of surgical site infections by the surgical team

    Directory of Open Access Journals (Sweden)

    Adriana Cristina de Oliveira

    2015-10-01

    Full Text Available AbstractOBJECTIVEEvaluate pre- and intraoperative practices adopted by medical and nursing teams for the prevention of surgical infections.METHODA prospective study carried out in the period of April to May 2013, in a surgical center of a university hospital in Belo Horizonte, Minas Gerais.RESULTS18 surgeries were followed and 214 surgical gloves were analyzed, of which 23 (10.7% had postoperative glove perforation detected, with 52.2% being perceived by users. Hair removal was performed on 27.7% of patients in the operating room, with the use of blades in 80% of the cases. Antibiotic prophylaxis was administered to 81.8% of patients up to 60 minutes prior to surgical incision. An average of nine professionals were present during surgery and the surgery room door remained open in 94.4% of the procedures.CONCLUSIONPartial adhesion to the recommended measures was identified, reaffirming a need for greater attention to these critical steps/actions in order to prevent surgical site infection.

  7. Fracture toughness measurements with subsize disk compact specimens

    International Nuclear Information System (INIS)

    Alexander, D.J.

    1994-01-01

    Special fixtures and test methods have been developed for testing small disk compact specimens (1.25 mm diam by 4.6 mm thick). Specimens of European type 316L austenitic stainless steel were irradiated to damage levels of about 3 dpa at nominal irradiation temperatures of either 90 or 250 C and tested over a temperature range from 20 to 250 C. Results show that irradiation to this dose level at these temperatures reduces the fracture toughness but the toughness remains quite high. The toughness decreases as the test temperature increases. Irradiation at 250 C is more damaging than at 90 C, causing larger decreases in the fracture toughness. The testing shows that it is possible to generate useful fracture toughness data with a small disk compact specimens

  8. Small specimen measurements of dynamic fracture toughness of heavy section steels for nuclear pressure vessel

    International Nuclear Information System (INIS)

    Tanaka, Y.; Iwadate, T.; Suzuki, K.

    1987-01-01

    This study presents the dynamic fracture toughness properties (KId) of 12 heats of RPV steels measured using small specimens and analysed based on the current research. The correlation between the KId test and other engineering small specimen tests such as Charpy test and drop weight test are also discussed and a method to predict the KId value is presented. (orig./HP)

  9. Material Stress Fringe Constant Measurement of Specimen under Pure Bending Load by Use of Photoelastic Phase Shifting Method

    International Nuclear Information System (INIS)

    Liu, Guan Yong; Kim, Myung Soo; Baek, Tae Hyun

    2014-01-01

    In a photoelastic experiment, it is necessary to know the material stress fringe constant of the photoelastic specimen to determine the stresses from the measured isochromatic fringe orders. The material stress fringe constant can be obtained using a simple tension specimen and/or a circular disk under diametric compression. In these methods, there is generally a need to apply numerous loads to the specimen in response to the relationship of the fringe order. Then, the least squares method is used to obtain the material constant. In this paper, the fringe orders that appear on a four-point bending specimen are used to determine the fringe constant. This method requires four photoelastic fringes obtained from a circular polariscope by rotating the analyzer to 0, π/4, π/2, and 3π/4 radians. Using the four-point bending specimen to determine the material stress fringe constant has an advantage because measurements can be made at different locations by applying a constant load. The stress fringe constant measured with this method is within the range suggested by the manufacturer of the photoelastic material

  10. Measuring the surgical 'learning curve': methods, variables and competency.

    Science.gov (United States)

    Khan, Nuzhath; Abboudi, Hamid; Khan, Mohammed Shamim; Dasgupta, Prokar; Ahmed, Kamran

    2014-03-01

    To describe how learning curves are measured and what procedural variables are used to establish a 'learning curve' (LC). To assess whether LCs are a valuable measure of competency. A review of the surgical literature pertaining to LCs was conducted using the Medline and OVID databases. Variables should be fully defined and when possible, patient-specific variables should be used. Trainee's prior experience and level of supervision should be quantified; the case mix and complexity should ideally be constant. Logistic regression may be used to control for confounding variables. Ideally, a learning plateau should reach a predefined/expert-derived competency level, which should be fully defined. When the group splitting method is used, smaller cohorts should be used in order to narrow the range of the LC. Simulation technology and competence-based objective assessments may be used in training and assessment in LC studies. Measuring the surgical LC has potential benefits for patient safety and surgical education. However, standardisation in the methods and variables used to measure LCs is required. Confounding variables, such as participant's prior experience, case mix, difficulty of procedures and level of supervision, should be controlled. Competency and expert performance should be fully defined. © 2013 The Authors. BJU International © 2013 BJU International.

  11. Variation in Surgical Quality Measure Adherence within Hospital Referral Regions: Do Publicly Reported Surgical Quality Measures Distinguish among Hospitals That Patients Are Likely to Compare?

    Science.gov (United States)

    Safavi, Kyan C; Dai, Feng; Gilbertsen, Todd A; Schonberger, Robert B

    2014-01-01

    Objective To determine whether surgical quality measures that Medicare publicly reports provide a basis for patients to choose a hospital from within their geographic region. Data Source The Department of Health and Human Services' public reporting website, Medicare Claims Processing Manual Baltimore, MD CMS http://www.medicare.gov/hospitalcompare. Study Design We identified hospitals (n = 2,953) reporting adherence rates to the quality measures intended to reduce surgical site infections (Surgical Care Improvement Project, 1–3) in 2012. We defined regions within which patients were likely to compare hospitals using the hospital referral regions (HRRs) from the Dartmouth Atlas of Health Care Project. We described distributions of reported SCIP adherence within each HRR, including medians, interquartile ranges (IQRs), skewness, and outliers. Principal Findings Ninety-seven percent of HRRs had median SCIP-1 scores ≥95 percent. In 93 percent of HRRs, half of the hospitals in the HRR were within 5 percent of the median hospital's score. In 62 percent of HRRs, hospitals were skewed toward the higher rates (negative skewness). Seven percent of HRRs demonstrated positive skewness. Only 1 percent had a positive outlier. SCIP-2 and SCIP-3 demonstrated similar distributions. Conclusions Publicly reported quality measures for surgical site infection prevention do not distinguish the majority of hospitals that patients are likely to choose from when selecting a surgical provider. More studies are needed to improve public reporting's ability to positively impact patient decision making. PMID:24611578

  12. SHOULD EVERY APPENDECECTOMY SPECIMEN BE SUBJECTED TO HISTOPATHOLOGICAL EXAMINATION? A RETROSPECTIVE STUDY OF HISTOLOGICAL FINDINGS IN APPENDICECTOMY SPECIMENS

    Directory of Open Access Journals (Sweden)

    Shahanuma Shaik

    2017-12-01

    Full Text Available BACKGROUND Appendicitis is one of the commonest surgical emergencies with a lifetime risk of 7-8%. The appendicectomy specimens operated upon clinically-suspected appendicitis often appear normal on gross examination, but histopathological evaluation may reveal a diverse underlying pathology. Therefore, for accurate diagnosis, histopathological examination of all appendicectomy specimens is mandatory. MATERIALS AND METHODS A retrospective study of 175 appendicectomy cases operated over a period of two years. The clinical data and histopathological reports were reviewed and various histopathological findings are categorised. RESULTS Out of the total 175 appendicectomies, 155 emergency appendicectomy cases were included in the study, while 20 cases of incidental appendicectomy were excluded. The peak incidence was found in the 2nd and 3rd decades with male predominance. Among the 155 specimens, 96.8% had histological features of appendicitis and 1.9% were normal appendix. The unusual histopathological findings were Carcinoid tumour and Enterobius vermicularis. CONCLUSION The definitive diagnoses of appendicitis as well as the unusual incidental findings that were missed intraoperatively are established by histopathological examination. The study supports the histological examination of all resected appendicectomy specimens.

  13. Molecular Auditing: An Evaluation of Unsuspected Tissue Specimen Misidentification.

    Science.gov (United States)

    Demetrick, Douglas J

    2018-06-18

    Context Specimen misidentification is the most significant error in laboratory medicine, potentially accounting for hundreds of millions of dollars in extra health care expenses and significant morbidity in patient populations in the United States alone. New technology allows the unequivocal documentation of specimen misidentification or contamination; however, the value of this technology currently depends on suspicion of the specimen integrity by a pathologist or other health care worker. Objective To test the hypothesis that there is a detectable incidence of unsuspected tissue specimen misidentification among cases submitted for routine surgical pathology examination. Design To test this hypothesis, we selected specimen pairs that were obtained at different times and/or different hospitals from the same patient, and compared their genotypes using standardized microsatellite markers used commonly for forensic human DNA comparison in order to identify unsuspected mismatches between the specimen pairs as a trial of "molecular auditing." We preferentially selected gastrointestinal, prostate, and skin biopsies because we estimated that these types of specimens had the greatest potential for misidentification. Results Of 972 specimen pairs, 1 showed an unexpected discordant genotype profile, indicating that 1 of the 2 specimens was misidentified. To date, we are unable to identify the etiology of the discordance. Conclusions These results demonstrate that, indeed, there is a low level of unsuspected tissue specimen misidentification, even in an environment with careful adherence to stringent quality assurance practices. This study demonstrates that molecular auditing of random, routine biopsy specimens can identify occult misidentified specimens, and may function as a useful quality indicator.

  14. Study of amended reports to evaluate and improve surgical pathology processes.

    Science.gov (United States)

    Meier, Frederick A; Varney, Ruan C; Zarbo, Richard J

    2011-09-01

    : Amended surgical pathology reports record defects in the process of transforming tissue specimens into diagnostic information. : Systematic study of amended reports tests 2 hypotheses: (a) that tracking amendment frequencies and the distribution of amendment types reveals relevant aspects of quality in surgical pathology's daily transformation of specimens into diagnoses and (b) that such tracking measures the effect, or lack of effect, of efforts to improve surgical pathology processes. : We applied a binary definition of altered reports as either amendments or addenda and a taxonomy of defects that caused amendments as misidentifications, specimen defects, misinterpretations, and report defects. During the introduction of a LEAN process improvement approach-the Henry Ford Productions System-we followed trends in amendment rates and defect fractions to (a) evaluate specific interventions, (b) sort case-by-case root causes of misidentifications, specimen defects, and misinterpretations, and (c) audit the ongoing accuracy of the classification of changed reports. LEAN is the management and production system of the Toyota Motor Corporation that promotes continuous improvement; it considers wasted resources expended for purposes other than creating value for end customers and targets such expenditures for elimination. : Introduction of real-time editing of amendments saw annual amendment rates increase from 4.8/1000 to 10.1/1000 and then decrease in an incremental manner to 5.6/1000 as Henry Ford Productions System-specific interventions were introduced. Before introduction of HFPS interventions, about a fifth of the amendments were due to misidentifications, a 10th were due to specimen defects, a quarter due to misinterpretation, and almost half were due to report defects. During the period of the initial application of HFPS, the fraction of amendments due to misidentifications decreased as those due to report defects increased, in a statistically linked manner. As

  15. Microbiology specimens obtained at the time of surgical lung biopsy for interstitial lung disease: clinical yield and cost analysis.

    Science.gov (United States)

    Fibla, Juan J; Brunelli, Alessandro; Allen, Mark S; Wigle, Dennis; Shen, Robert; Nichols, Francis; Deschamps, Claude; Cassivi, Stephen D

    2012-01-01

    In efforts to obtain complete results, current practice in surgical lung biopsy (LB) for interstitial lung disease (ILD) recommends sending lung tissue samples for bacterial, mycobacterial, fungal, and viral cultures. This study assesses the value of this practice by evaluating the microbiology findings obtained from LB for ILD and their associated costs. A total of 296 consecutive patients (140 women, 156 men, median age=61 years) underwent LB for ILD from 2002 to 2009. All had lung tissue sent for microbiology examination. Microbiology results and resultant changes in patient management were analyzed retrospectively. A cost analysis was performed based upon nominal hospital charges adjusted on current inflation rates. Cost data included cultures, stains, smears, direct fluorescent antibody studies, and microbiologist consulting fees. As many as 25 patients (8.4%) underwent open LB and 271 (91.6%) underwent thoracoscopic LB. A total of 592 specimens were assessed (range 1-4 per patient). The most common pathologic diagnoses were idiopathic pulmonary fibrosis in 122 (41.2%), cryptogenic organizing pneumonia in 31 (10.5%), and respiratory bronchiolitis ILD in 16 (5.4%). Microbiology testing was negative in 174 patients (58.8%). A total of 118 of 122 (96.7%) positive results were clinically considered to be contaminants and resulted in no change in clinical management. The most common contaminants were Propionibacterium acnes (38 patients; 31%) and Penicillium fungus (16 patients; 13%). In only four patients (1.4%), the organism cultured (Nocardia one, Histoplasma one, and Aspergillus fumigatus two) resulted in a change in clinical management. The cost of microbiology studies per specimen was $984 (€709), with a total cost for the study cohort being $582,000 (€420,000). The yield and impact on clinical management of microbiology specimens from LB for ILD is very low. Its routine use in LB is questionable. We suggest it should be limited to those cases of ILD with

  16. Measurement on the density resolution of industrial computerized tomography by using disc specimen with holes

    International Nuclear Information System (INIS)

    Tian, Y.; Gao, D.; Zhang, W.; Xia, Z.; Yang, C.

    2004-01-01

    Several ways mainly used for measuring the density resolution of industrial computerized tomography (ICT) are briefly introduced. Based on the equivalent conversion between volume variation and density variation, a kind of disc specimen with holes is designed to measure the density resolution of ICT. In this experiment, a kind of high quality polymethyl methacylate (PMMA) is selected to make specimens with diameter of 250mm, in which six sets of holes with diameter separately 0.5mm, 1.0mm, 1.5mm, 2.0mm, 2.5mm, and 3.0mm are distributed in the radial directions with interval of 60 o between two neighboring sets, and in the same set, the distances of holes departing the center of the specimen are respectively 20mm, 40mm, 60mm, 80mm, and 100mm. The experiment shows that the method is sensitive, simple, flexible, and practical. About 0.2% density resolution of region of interest (ROI) with diameter 20mm can be verified, the relationship between CT value of ROI and its position can be obtained, and at the same time the spatial resolution of ICT can be measured in high quality. (author)

  17. A J Integral Approach for Measuring Cohesive Laws Using a Modified DCB Sandwich Specimen

    DEFF Research Database (Denmark)

    Lundsgaard-Larsen, Christian; Berggreen, Christian; Sørensen, Bent F.

    2007-01-01

    mode mixities. The sandwich specimen consists of glass fiber faces and Divinycell H200 foam core. Arbitrary stiffening of the sandwich specimen with steel bars adhered to the faces reduces rotations and ensures that the method is useable for a wide range of materials. The J integral is employed...... and the opening of the pre-crack tip is recorded by a commercial digital photogrammetry measurement system. Cohesive laws are extracted by differentiating J with respect to the normal and tangential opening of the pre-crack tip. Some results are presented and discussed....

  18. Measurement of specimen-induced aberrations of biological samples using phase stepping interferometry.

    Science.gov (United States)

    Schwertner, M; Booth, M J; Neil, M A A; Wilson, T

    2004-01-01

    Confocal or multiphoton microscopes, which deliver optical sections and three-dimensional (3D) images of thick specimens, are widely used in biology. These techniques, however, are sensitive to aberrations that may originate from the refractive index structure of the specimen itself. The aberrations cause reduced signal intensity and the 3D resolution of the instrument is compromised. It has been suggested to correct for aberrations in confocal microscopes using adaptive optics. In order to define the design specifications for such adaptive optics systems, one has to know the amount of aberrations present for typical applications such as with biological samples. We have built a phase stepping interferometer microscope that directly measures the aberration of the wavefront. The modal content of the wavefront is extracted by employing Zernike mode decomposition. Results for typical biological specimens are presented. It was found for all samples investigated that higher order Zernike modes give only a small contribution to the overall aberration. Therefore, these higher order modes can be neglected in future adaptive optics sensing and correction schemes implemented into confocal or multiphoton microscopes, leading to more efficient designs.

  19. Measurement of the yield and tensile strengths of neutron-irradiated and post-irradiation recovered vessel steels with notched specimens

    International Nuclear Information System (INIS)

    Valiente, A.

    1996-01-01

    Tensile circumferentially notched bars are examined as test specimens for measuring the yield and tensile strengths of nuclear pressure vessel steels under several conditions of irradiation and temperature that a vessel can experience during its service life, including recovery post-irradiation treatment. For all the vessel steels, notch geometries and conditions explored, it has been found that notched specimens fail by plastic collapse, and simple formulae have been derived that allow the yield and tensile strengths to be determined from the yielding and plastic collapse load of a notched specimen. Values measured in this way show good agreement with those measured by the standard tensile test method. (orig.)

  20. Quality measurement affecting surgical practice: Utility versus utopia.

    Science.gov (United States)

    Henry, Leonard R; von Holzen, Urs W; Minarich, Michael J; Hardy, Ashley N; Beachy, Wilbur A; Franger, M Susan; Schwarz, Roderich E

    2018-03-01

    The Triple Aim: improving healthcare quality, cost and patient experience has resulted in massive healthcare "quality" measurement. For many surgeons the origins, intent and strengths of this measurement barrage seems nebulous-though their shortcomings are noticeable. This article reviews the major organizations and programs (namely the Centers for Medicare and Medicaid Services) driving the somewhat burdensome healthcare quality climate. The success of this top-down approach is mixed, and far from convincing. We contend that the current programs disproportionately reflect the definitions of quality from (and the interests of) the national payer perspective; rather than a more balanced representation of all stakeholders interests-most importantly, patients' beneficence. The result is an environment more like performance management than one of valid quality assessment. Suggestions for a more meaningful construction of surgical quality measurement are offered, as well as a strategy to describe surgical quality from all of the stakeholders' perspectives. Our hope is to entice surgeons to engage in institution level quality improvement initiatives that promise utility and are less utopian than what is currently present. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. A semiautomatic CT-based ensemble segmentation of lung tumors: comparison with oncologists' delineations and with the surgical specimen.

    Science.gov (United States)

    Rios Velazquez, Emmanuel; Aerts, Hugo J W L; Gu, Yuhua; Goldgof, Dmitry B; De Ruysscher, Dirk; Dekker, Andre; Korn, René; Gillies, Robert J; Lambin, Philippe

    2012-11-01

    To assess the clinical relevance of a semiautomatic CT-based ensemble segmentation method, by comparing it to pathology and to CT/PET manual delineations by five independent radiation oncologists in non-small cell lung cancer (NSCLC). For 20 NSCLC patients (stages Ib-IIIb) the primary tumor was delineated manually on CT/PET scans by five independent radiation oncologists and segmented using a CT based semi-automatic tool. Tumor volume and overlap fractions between manual and semiautomatic-segmented volumes were compared. All measurements were correlated with the maximal diameter on macroscopic examination of the surgical specimen. Imaging data are available on www.cancerdata.org. High overlap fractions were observed between the semi-automatically segmented volumes and the intersection (92.5±9.0, mean±SD) and union (94.2±6.8) of the manual delineations. No statistically significant differences in tumor volume were observed between the semiautomatic segmentation (71.4±83.2 cm(3), mean±SD) and manual delineations (81.9±94.1 cm(3); p=0.57). The maximal tumor diameter of the semiautomatic-segmented tumor correlated strongly with the macroscopic diameter of the primary tumor (r=0.96). Semiautomatic segmentation of the primary tumor on CT demonstrated high agreement with CT/PET manual delineations and strongly correlated with the macroscopic diameter considered as the "gold standard". This method may be used routinely in clinical practice and could be employed as a starting point for treatment planning, target definition in multi-center clinical trials or for high throughput data mining research. This method is particularly suitable for peripherally located tumors. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  2. Design of specimen for weld residual stress simulation

    International Nuclear Information System (INIS)

    Kim, Jin Weon; Park, Jong Sun; Lee, Kyung Soo

    2008-01-01

    The objective of this study is to design a laboratory specimen for simulating residual stress of circumferential butt welding of pipe. Specimen type and method for residual stress generation were proposed based on the review of prior studies and parametric finite element simulation. To prove the proposed specimen type and loading method, the residual stress was generated using the designed specimen by applying proposed method and was measured. The measured residual stress using X-ray diffraction reasonably agreed with the results of finite element simulation considered in the specimen design. Comparison of residual strains measured at several locations of specimen and given by finite element simulation also showed good agreement. Therefore, it is indicated that the designed specimen can reasonably simulate the residual stress of circumferential butt welding of pipe

  3. Measurement and accompanying numerical simulation of fast crack propagation in modified DCB specimens made of Araldit B

    International Nuclear Information System (INIS)

    Stoeckl, H.

    1991-06-01

    Numerical simulations of fracture-mechanical experiments with the aim of determining the stress intensity factor and its relation to the fracture velocity from the measured data of the crack length are problematic with the conventional DCB specimen loaded through wedge and bolt namely because of the not clearly definable limiting conditions. Experiments were therefore carried out with modified DCB specimens made of ARALDIT B, with the loading wedge pressed directly into the crack mouth. In the case of suitable specimen dimensions, K I already in the initial phase of crack propagation before arrival of the first reflected waves covers a great part of the relevant range. Numerical simulations agree well with the shadow-optical measurements in this phase. A specimen variant with T-shaped extension at the counterbearing is suitable especially for crack arrest investigations, since high fracture velocities and brief crack jump lengths can be combined in tests with this specimen. The constant member in the series development of the stress distribution at the crack tip according to Williams determines the directional stability of the crack. The theories established by Cotterell, Schindler, Streit and Finnie are discussed by means of the kinking cracks observed during some experiments. (orig.) [de

  4. Method for independent strain and temperature measurement in polymeric tensile test specimen using embedded FBG sensors

    DEFF Research Database (Denmark)

    Pereira, Gilmar Ferreira; McGugan, Malcolm; Mikkelsen, Lars Pilgaard

    2016-01-01

    to calculate independently the strain and temperature are presented in the article, together with a measurement resolution study. This multi-parameter measurement method was applied to an epoxy tensile specimen, tested in a unidirectional tensile test machine with a temperature controlled cabinet. A full......A novel method to obtain independent strain and temperature measurements using embedded Fibre Bragg Grating (FBG) in polymeric tensile test specimens is presented in this paper. The FBG strain and temperature cross-sensitivity was decoupled using two single mode FBG sensors, which were embedded...... of temperature, from 40 C to -10 C. The consistency of the expected theoretical results with the calibration procedure and the experimental validation shows that this proposed method is applicable to measure accurate strain and temperature in polymers during static or fatigue tensile testing. Two different...

  5. Splitting tests on rock specimens

    Energy Technology Data Exchange (ETDEWEB)

    Davies, J D; Stagg, K G

    1970-01-01

    Splitting tests are described for a square-section sandstone specimens line loaded through steel or timber packings on the top face and supported on the bottom face either on similar packings (type A specimen) or directly on the lower platen plate of the testing machine (type B specimens). The stress distribution across the vertical central plane and the horizontal central plane were determined from a linear elastic finite element analysis for both types. Two solutions were obtained for the type B specimen: one assuming no friction between the base of the specimen and the platen plate and the other assuming no relative slip between the surfaces. Vertical and horizontal strains were measured at the center of the specimens for all loads up to failure.

  6. In-situ measurement of the strain distribution in a tensile specimen by using a digital speckle pattern interferometer

    International Nuclear Information System (INIS)

    Park, Seung-Kyu; Baik, Sung-Hoon; Cha, Hyung-Ki; Kim, Young-Suk; Cheong, Yong-Moo

    2010-01-01

    Less sensitivity to environmental vibrations is essential for industrial applications of a digital speckle pattern interferometer (DSPI) to measure micro deformations. In this paper, a robust DSPI using single fringe to mechanical vibrations is designed for measuring the strain distribution of a tensile specimen. This system adopts a noise-immune signal processing algorithm to acquire a 3D strain distribution image. To acquire an accurate strain distribution for a tensile-specimen, locally-averaged and directionally-oriented filters operating in the frequency domain are used. This system uses a path-independent least-squares phase-unwrapping algorithm to acquire the 3D shape of the strain distribution. As for the initial experiments to measure the strain distribution of a tensile specimen in a vibration field, this system demonstrated a feasibility for industrial applications by providing reliable strain data.

  7. A simple method for the prevention of endometrial autolysis in hysterectomy specimens

    OpenAIRE

    Houghton, J P; Roddy, S; Carroll, S; McCluggage, W G

    2004-01-01

    Aims: Uteri are among the most common surgical pathology specimens. Assessment of the endometrium is often difficult because of pronounced tissue autolysis. This study describes a simple method to prevent endometrial autolysis and aid in interpretation of the endometrium.

  8. Miniature Precracked Charpy Specimens for Measuring the Master Curve Reference Temperature of RPV Steels at Impact Loading Rates

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.; Scibetta, M.; Puzzolante, L.

    2008-10-15

    In the framework of the 2006 Convention, we investigated the applicability of fatigue precracked miniature Charpy specimens of KLST type (MPCC - B = 3 mm, W = 4 mm and L = 27 mm) for impact toughness measurements, using the well-characterized JRQ RPV steel. In the ductile to-brittle transition region, MPCC tests analyzed using the Master Curve approach and compared to data previously obtained from PCC specimens had shown a more ductile behavior and therefore un conservative results. In the investigation presented in this report, two additional RPV steels have been used to compare the performance of impact-tested MPCC and PCC specimens in the transition regime: the low-toughness JSPS steel and the high-toughness 20MnMoNi55 steel. The results obtained (excellent agreement for 20MnMoNi55 and considerable differences between T0 values for JSPS) are contradictory and do not presently allow qualifying the MPCC specimens as a reliable alternative to PCC samples for impact toughness measurements.

  9. Development of a strain measurement method for non-plane specimens by means of computer picture processing

    International Nuclear Information System (INIS)

    Yoshioka, Akira; Soneda, Naoki; Yagawa, Genki; Miyoshi, Akio.

    1988-01-01

    Integrity Tests of the Fast Breeder Reactor components are often conducted at an elevated temperature, say 550deg C. Since high-temperature strain measurement using special strain gauges is costly and unappropriate for large and repeated strains, the authors have developed an optical strain measurement method and system based on computer picture processing and the triangulation principle. The present method enables us to measure the strain in specimen with curved surfaces. Its operation is also easy, because of the automatic distinction of marks from noises. The verification tests with a plate specimen and a cylindrical one are performed under elevated temperatures. The results show that the present method is very suitable to the tests under elevated temperatures and that the measurement error of strain is within 0.2 % (2000μ), which is reasonable considering the limitation of hardware. (author)

  10. Measuring ERCC1 protein expression in cancer specimens

    DEFF Research Database (Denmark)

    Smith, David Hersi; Fiehn, Anne-Marie Kanstrup; Fogh, Louise

    2014-01-01

    Platinum chemotherapy remains part of standard therapies in the management of a variety of cancers. Severe side effects and a high degree of resistance to platinum drugs have led numerous researchers to search for predictive biomarkers, which could aid in identifying patients that are the most......, the specificity of antibody 4F9 was tested by immunoblotting, immunohistochemistry and immunofluorescence. Scoring guidelines to aid in the evaluation of ERCC1 tumor expression were developed and evaluated in archival formalin-fixed paraffin embedded colorectal cancer specimens. Antibody 4F9 was found...... to be specific by all methods applied and it was possible to evaluate the ERCC1 expression in the majority (85%) of colorectal cancer tumor specimens....

  11. Comparison of refractometry and biuret assay for measurement of total protein concentration in canine abdominal and pleural fluid specimens.

    Science.gov (United States)

    Rose, Alexandra; Funk, Deborah; Neiger, Reto

    2016-04-01

    To compare total protein (TP) concentrations in canine pleural and abdominal fluid specimens as measured by refractometry and biuret assay. Diagnostic test evaluation. Data regarding 92 pleural and 148 abdominal fluid specimens from dogs with various diseases. TP concentrations in fluid specimens as measured by refractometry and biuret assay were recorded. Strength of association between sets of measurements was assessed by Spearman rank correlations and Bland-Altman plots. Optimal concentration cutoff for diagnostic discrimination between exudate and nonexudate was identified by construction of receiver operating characteristic curves. Median TP concentration in pleural fluid specimens was 2.7 g/dL (range, 0.3 to 4.8 g/dL) for refractometry and 2.9 g/dL (range, 0.7 to 5.8 g/dL) for biuret assay. Median TP concentration in abdominal fluid specimens was 3.5 g/dL (range, 0.1 to 6.0 g/dL) for refractometry and 3.5 g/dL (range, 0.6 to 5.7 g/dL) for biuret assay. Correlation was significant between refractometric and biuret results for pleural (ρ = 0.921) and abdominal (ρ = 0.908) fluid. Bland-Altman plots revealed bias of -0.18 g/dL for pleural fluid and -0.03 g/dL for abdominal fluid for refractometry versus biuret assay. With a TP concentration of ≥ 3 g/dL used to distinguish exudate from nonexudate, sensitivity of refractometry was 77% for pleural fluid and 80% for abdominal fluid. Specificity was 100% and 94%, respectively. Refractometry yielded acceptable results for measurement of TP concentration in canine pleural and abdominal fluid specimens, providing a more rapid and convenient method than biuret assay.

  12. Computer assisted surgical anatomy mapping : applications in surgical anatomy research, tailor-made surgery and presonalized teaching

    NARCIS (Netherlands)

    A.L.A. Kerver (Anton)

    2017-01-01

    markdownabstractThis thesis presents a novel anatomy mapping tool named Computer Assisted Surgical Anatomy Mapping (CASAM). It allows researchers to map complex anatomy of multiple specimens and compare their location and course. Renditions such as safe zones or danger zones can be visualized,

  13. Influence of surgical decompression on the expression of inflammatory and tissue repair biomarkers in periapical cysts.

    Science.gov (United States)

    Rodrigues, Janderson Teixeira; Dos Santos Antunes, Henrique; Armada, Luciana; Pires, Fábio Ramôa

    2017-12-01

    The biologic effects of surgical decompression on the epithelium and connective tissues of periapical cysts are not fully understood. The aim of this study was to evaluate the expression of tissue repair and inflammatory biomarkers in periapical cysts before and after surgical decompression. Nine specimens of periapical cysts treated with decompression before undergoing complete enucleation were immunohistochemically analyzed to investigate the expression of interleukin-1β, tumor necrosis factor-α, transforming growth factor-β1, matrix metalloproteinase-9, Ki-67, and epidermal growth factor receptor. Expression of the biomarkers was classified as positive, focal, or negative. Ki-67 immunoexpression was calculated as a cell proliferation index. The expression of the biomarkers was compared in the specimens from decompression and from the final surgical procedure. Computed tomography demonstrated that volume was reduced in all cysts after decompression. There were no differences in the immunoexpression of the proinflammatory and tissue repair biomarkers when comparing the specimens obtained before and after the decompression. Surgical decompression was efficient in reducing the volume of periapical cysts before complete enucleation. When comparing the specimens obtained from surgical decompression and from complete surgical removal, the immunohistochemical analysis did not show a decrease in proinflammatory biomarkers; neither did it show an increase in tissue repair biomarkers. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Network analysis of surgical innovation: Measuring value and the virality of diffusion in robotic surgery.

    Science.gov (United States)

    Garas, George; Cingolani, Isabella; Panzarasa, Pietro; Darzi, Ara; Athanasiou, Thanos

    2017-01-01

    Existing surgical innovation frameworks suffer from a unifying limitation, their qualitative nature. A rigorous approach to measuring surgical innovation is needed that extends beyond detecting simply publication, citation, and patent counts and instead uncovers an implementation-based value from the structure of the entire adoption cascades produced over time by diffusion processes. Based on the principles of evidence-based medicine and existing surgical regulatory frameworks, the surgical innovation funnel is described. This illustrates the different stages through which innovation in surgery typically progresses. The aim is to propose a novel and quantitative network-based framework that will permit modeling and visualizing innovation diffusion cascades in surgery and measuring virality and value of innovations. Network analysis of constructed citation networks of all articles concerned with robotic surgery (n = 13,240, Scopus®) was performed (1974-2014). The virality of each cascade was measured as was innovation value (measured by the innovation index) derived from the evidence-based stage occupied by the corresponding seed article in the surgical innovation funnel. The network-based surgical innovation metrics were also validated against real world big data (National Inpatient Sample-NIS®). Rankings of surgical innovation across specialties by cascade size and structural virality (structural depth and width) were found to correlate closely with the ranking by innovation value (Spearman's rank correlation coefficient = 0.758 (p = 0.01), 0.782 (p = 0.008), 0.624 (p = 0.05), respectively) which in turn matches the ranking based on real world big data from the NIS® (Spearman's coefficient = 0.673;p = 0.033). Network analysis offers unique new opportunities for understanding, modeling and measuring surgical innovation, and ultimately for assessing and comparing generative value between different specialties. The novel surgical innovation metrics developed may

  15. Surgical site infection rates following laparoscopic urological procedures.

    Science.gov (United States)

    George, Arvin K; Srinivasan, Arun K; Cho, Jane; Sadek, Mostafa A; Kavoussi, Louis R

    2011-04-01

    Surgical site infections have been categorized by the Centers for Medicare and Medicaid Services as "never events". The incidence of surgical site infection following laparoscopic urological surgery and its risk factors are poorly defined. We evaluated surgical site infection following urological laparoscopic surgery and identified possible factors that may influence occurrence. Patients who underwent transperitoneal laparoscopic procedures during a 4-year period by a single laparoscopic surgeon were retrospectively reviewed. Surgical site infections were identified postoperatively and defined using the Centers for Disease Control criteria. Clinical parameters, comorbidities, smoking history, preoperative urinalysis and culture results as well as operative data were analyzed. Nonparametric testing using the Mann-Whitney U test, multivariable logistic regression and Spearman's rank correlation coefficient were used for data analysis. In 556 patients undergoing urological laparoscopic procedures 14 surgical site infections (2.5%) were identified at mean postoperative day 21.5. Of the 14 surgical site infections 10 (71.4%) were located at a specimen extraction site. Operative time, procedure type and increasing body mass index were significantly associated with the occurrence of surgical site infections (p = 0.007, p = 0.019, p = 0.038, respectively), whereas history of diabetes mellitus (p = 0.071) and intraoperative transfusion (p = 0.053) were found to trend toward significance. Age, gender, positive urine culture, steroid use, procedure type and smoking history were not significantly associated with surgical site infection. Body mass index and operative time remained significant predictors of surgical site infection on multivariate logistic regression analysis. Surgical site infection is an infrequent complication following laparoscopic surgery with the majority occurring at the specimen extraction site. Infection is associated with prolonged operative time and

  16. Evaluating Robotic Surgical Skills Performance Under Distractive Environment Using Objective and Subjective Measures.

    Science.gov (United States)

    Suh, Irene H; LaGrange, Chad A; Oleynikov, Dmitry; Siu, Ka-Chun

    2016-02-01

    Distractions are recognized as a significant factor affecting performance in safety critical domains. Although operating rooms are generally full of distractions, the effect of distractions on robot-assisted surgical (RAS) performance is unclear. Our aim was to investigate the effect of distractions on RAS performance using both objective and subjective measures. Fifteen participants performed a knot-tying task using the da Vinci Surgical System and were exposed to 3 distractions: (1) passive distraction entailed listening to noise with a constant heart rate, (2) active distraction included listening to noise and acknowledging a change of random heart rate from 60 to 120 bpm, and (3) interactive distraction consisted of answering math questions. The objective kinematics of the surgical instrument tips were used to evaluate performance. Electromyography (EMG) of the forearm and hand muscles of the participants were collected. The median EMG frequency (EMG(fmed)) and the EMG envelope (EMG(env)) were analyzed. NASA Task Load Index and Fundamentals of Laparoscopic Surgery score were used to evaluate the subjective performance. One-way repeated analysis of variance was applied to examine the effects of distraction on skills performance. Spearman's correlations were conducted to compare objective and subjective measures. Significant distraction effect was found for all objective kinematics measures (P < .05). There were significant distraction effects for EMG measures (EMG(env), P < .004; EMG(fmed), P = .031). Significant distraction effects were also found for subjective measurements. Distraction impairs surgical skills performance and increases muscle work. Understanding how the surgeons cope with distractions is important in developing surgical education. © The Author(s) 2015.

  17. Innovations in macroscopic evaluation of pancreatic specimens and radiologic correlation

    International Nuclear Information System (INIS)

    Triantopoulou, Charikleia; Papaparaskeva, Kleo; Agalianos, Christos; Dervenis, Christos

    2016-01-01

    •The axial slicing technique offers many advantages in accurate estimation of tumors extend and staging.•Cross-sectional axial imaging is the best technique for accurate radiologic-pathologic correlation.•Correlation may explain any discrepancies between radiological and histopathological findings.•Pathology correlation may offer a better understanding of the missed findings by imaging or pitfalls The axial slicing technique offers many advantages in accurate estimation of tumors extend and staging. Cross-sectional axial imaging is the best technique for accurate radiologic-pathologic correlation. Correlation may explain any discrepancies between radiological and histopathological findings. Pathology correlation may offer a better understanding of the missed findings by imaging or pitfalls The purpose of this study was to evaluate the feasibility of a novel dissection technique of surgical specimens in different cases of pancreatic tumors and provide a radiologic pathologic correlation. In our hospital, that is a referral center for pancreatic diseases, the macroscopic evaluation of the pancreatectomy specimens is performed by the pathologists using the axial slicing technique (instead of the traditional procedure with longitudinal opening of the main pancreatic and/or common bile duct and slicing along the plane defined by both ducts). The specimen is sliced in an axial plane that is perpendicular to the longitudinal axis of the descending duodenum. The procedure results in a large number of thin slices (3–4 mm). This plane is identical to that of CT or MRI and correlation between pathology and imaging is straightforward. We studied 70 cases of suspected different solid and cystic pancreatic tumors and we correlated the tumor size and location, the structure—consistency (areas of necrosis—hemorrhage—fibrosis—inflammation), the degree of vessels’ infiltration, the size of pancreatic and common bile duct and the distance from resection margins

  18. [Safety management in pathology laboratory: from specimen handling to confirmation of reports].

    Science.gov (United States)

    Minato, Hiroshi; Nojima, Takayuki; Nakano, Mariko; Yamazaki, Michiko

    2011-03-01

    Medical errors in pathological diagnosis give a huge amount of physical and psychological damage to patients as well as medical staffs. We discussed here how to avoid medical errors in surgical pathology laboratory through our experience. Handling of surgical specimens and diagnosing process requires intensive labor and involves many steps. Each hospital reports many kinds of accidents or incidents, however, many laboratories share common problems and each process has its specific risk for the certain error. We analyzed the problems in each process and concentrated on avoiding misaccessioning, mislabeling, and misreporting. We have made several changes in our system, such as barcode labels, digital images of all specimens, putting specimens in embedding cassettes directly on the endoscopic biopsied specimens, and using a multitissue control block as controls in immunohistochemistry. Some problems are still left behind, but we have reduced the errors by decreasing the number of artificial operation as much as possible. A pathological system recognizing the status of read or unread the pathological reports by clinician are now underconstruction. We also discussed about quality assurance of diagnosis, cooperation with clinicians and other comedical staffs, and organization and method. In order to operate riskless work, it is important for all the medical staffs to have common awareness of the problems, keeping careful observations, and sharing all the information in common. Incorporation of an organizational management tool such as ISO 15189 and utilizing PDCA cycle is also helpful for safety management and quality improvement of the laboratory.

  19. Screen-film specimen radiography

    International Nuclear Information System (INIS)

    Shepard, S.J.; Hogan, J.; Schreck, B.

    1990-01-01

    This paper reports on the reproducibility and quality of biopsy specimen radiographs, a unique phototimed cabinet x-ray system is being developed. The system utilizes specially modified Kodal Min-R cassettes and will be compatible with current mammographic films. Tube voltages are in the 14-20-kVp range with 0.1-1.0-second exposure times. A top-hat type compression device is used (1) to compress the specimen to uniform thickness, (2) to measure the specimen thickness and determine optimum kVp, and (3) to superimpose a grid over the specimen for identification of objects of radiographic interest. The phototiming circuit developed specifically for this purpose will be described along with the modified Min-R cassette. Characteristics of the generator and cabinet will also be described. Tests will be performed on phantoms to evaluate the system limitations

  20. Ambulatory Surgical Measures - Facility

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Ambulatory Surgical Center Quality Reporting (ASCQR) Program seeks to make care safer and more efficient through quality reporting. ASCs eligible for this...

  1. Network analysis of surgical innovation: Measuring value and the virality of diffusion in robotic surgery.

    Directory of Open Access Journals (Sweden)

    George Garas

    Full Text Available Existing surgical innovation frameworks suffer from a unifying limitation, their qualitative nature. A rigorous approach to measuring surgical innovation is needed that extends beyond detecting simply publication, citation, and patent counts and instead uncovers an implementation-based value from the structure of the entire adoption cascades produced over time by diffusion processes. Based on the principles of evidence-based medicine and existing surgical regulatory frameworks, the surgical innovation funnel is described. This illustrates the different stages through which innovation in surgery typically progresses. The aim is to propose a novel and quantitative network-based framework that will permit modeling and visualizing innovation diffusion cascades in surgery and measuring virality and value of innovations.Network analysis of constructed citation networks of all articles concerned with robotic surgery (n = 13,240, Scopus® was performed (1974-2014. The virality of each cascade was measured as was innovation value (measured by the innovation index derived from the evidence-based stage occupied by the corresponding seed article in the surgical innovation funnel. The network-based surgical innovation metrics were also validated against real world big data (National Inpatient Sample-NIS®.Rankings of surgical innovation across specialties by cascade size and structural virality (structural depth and width were found to correlate closely with the ranking by innovation value (Spearman's rank correlation coefficient = 0.758 (p = 0.01, 0.782 (p = 0.008, 0.624 (p = 0.05, respectively which in turn matches the ranking based on real world big data from the NIS® (Spearman's coefficient = 0.673;p = 0.033.Network analysis offers unique new opportunities for understanding, modeling and measuring surgical innovation, and ultimately for assessing and comparing generative value between different specialties. The novel surgical innovation metrics

  2. Fatigue life determination by damage measuring in SAE 8620 specimens steel subjected to multiaxial experiments in neutral and corrosive environment

    International Nuclear Information System (INIS)

    Silva, Luiz L. da; Filho, Nelson do N.A.; Gomes, Paulo de T.V.; Rabello, Emerson G.; Mansur, Tanius R.

    2013-01-01

    Fatigue is the fail phenomenon of a material subjected to cyclic loads. This phenomenon affects any component under loads (forces, temperatures, etc.) that changes in time. When there is a combined load, originating multiaxial fatigue, which is the most of the real loads, worst is the situation. Before the component fail, the fatigue phenomenon produces damages to its material and this is a cumulative process that could not be reduced. In the continuum mechanic context, material damage is defined as a parameter that reduces the component resistance and this could cause its fail. The process of damage measuring by changes in electrical resistance is used in this work, and from experimental results of SAE 8620 steel specimens subjected to multiaxial fatigue in corrosive and neutral environment, the remaining specimen time life could be determined. Each specimen has its initial electrical resistance measured and after a certain number of fatigue cycles stopping points, its electrical resistance was measured again. In order to study multiaxial fatigue in specimens, a machine that induces simultaneously bending and torsional loads in the specimen was developed. Air at the temperature range of 18 deg C and 20 deg C was considered neutral environment. The corrosive environment was a NaCl solution with a concentration of 3,5% in weigh. The experimental results showed that the measuring fatigue damage using the changes in electrical resistance is efficient and that is possible to estimate the effect of a corrosive environment in the fatigue damage. (author)

  3. Quantitative measurement of mean inner potential and specimen thickness from high-resolution off-axis electron holograms of ultra-thin layered WSe2.

    Science.gov (United States)

    Winkler, Florian; Tavabi, Amir H; Barthel, Juri; Duchamp, Martial; Yucelen, Emrah; Borghardt, Sven; Kardynal, Beata E; Dunin-Borkowski, Rafal E

    2017-07-01

    The phase and amplitude of the electron wavefunction that has passed through ultra-thin flakes of WSe 2 is measured from high-resolution off-axis electron holograms. Both the experimental measurements and corresponding computer simulations are used to show that, as a result of dynamical diffraction, the spatially averaged phase does not increase linearly with specimen thickness close to an [001] zone axis orientation even when the specimen has a thickness of only a few layers. It is then not possible to infer the local specimen thickness of the WSe 2 from either the phase or the amplitude alone. Instead, we show that the combined analysis of phase and amplitude from experimental measurements and simulations allows an accurate determination of the local specimen thickness. The relationship between phase and projected potential is shown to be approximately linear for extremely thin specimens that are tilted by several degrees in certain directions from the [001] zone axis. A knowledge of the specimen thickness then allows the electrostatic potential to be determined from the measured phase. By using this combined approach, we determine a value for the mean inner potential of WSe 2 of 18.9±0.8V, which is 12% lower than the value calculated from neutral atom scattering factors. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  4. Development of a penetration friction apparatus (PFA) to measure the frictional performance of surgical suture.

    Science.gov (United States)

    Zhang, Gangqiang; Ren, Tianhui; Lette, Walter; Zeng, Xiangqiong; van der Heide, Emile

    2017-10-01

    Nowadays there is a wide variety of surgical sutures available in the market. Surgical sutures have different sizes, structures, materials and coatings, whereas they are being used for various surgeries. The frictional performances of surgical sutures have been found to play a vital role in their functionality. The high friction force of surgical sutures in the suturing process may cause inflammation and pain to the person, leading to a longer recovery time, and the second trauma of soft or fragile tissue. Thus, the investigation into the frictional performance of surgical suture is essential. Despite the unquestionable fact, little is actually known on the friction performances of surgical suture-tissue due to the lack of appropriate test equipment. This study presents a new penetration friction apparatus (PFA) that allowed for the evaluation of the friction performances of various surgical needles and sutures during the suturing process, under different contact conditions. It considered the deformation of tissue and can realize the puncture force measurements of surgical needles as well as the friction force of surgical sutures. The developed PFA could accurately evaluate and understand the frictional behaviour of surgical suture-tissue in the simulating clinical conditions. The forces measured by the PFA showed the same trend as that reported in literatures. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Use of the strength ratio for pre-cracked Charpy specimens for the measuring, of the dynamic toughness of steels

    International Nuclear Information System (INIS)

    Pereira, L.C.; Darwish, F.A.I.

    1981-01-01

    The specimen strength ratio (R sub(sb)) determined for precraked Charpy specimens fractured in dynamic bending was correlated with plane strain fracture toughness (K sub(Id)) obtained through valid measurements of the J-integral at the moment of fracture initiation in various microstructures of the AISI 4140 steel. The results indicate a linear relationship between K sub(Id) and R sub(sb) for the microstructures considered in this work. The range of validity of this linear correlation is presented and discussed in terms of the ASTM E399 specimen size criterion. (Author) [pt

  6. Quantitative measurement of mean inner potential and specimen thickness from high-resolution off-axis electron holograms of ultra-thin layered WSe{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Florian, E-mail: f.winkler@fz-juelich.de [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons (ER-C), Forschungszentrum Jülich, D-52425 Jülich (Germany); Peter Grünberg Institute 5 (PGI-5), Forschungszentrum Jülich, D-52425 Jülich (Germany); Tavabi, Amir H. [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons (ER-C), Forschungszentrum Jülich, D-52425 Jülich (Germany); Peter Grünberg Institute 5 (PGI-5), Forschungszentrum Jülich, D-52425 Jülich (Germany); Barthel, Juri [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons (ER-C), Forschungszentrum Jülich, D-52425 Jülich (Germany); Gemeinschaftslabor für Elektronenmikroskopie (GFE), RWTH Aachen University, D-52074 Aachen (Germany); Duchamp, Martial [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons (ER-C), Forschungszentrum Jülich, D-52425 Jülich (Germany); Peter Grünberg Institute 5 (PGI-5), Forschungszentrum Jülich, D-52425 Jülich (Germany); Yucelen, Emrah [FEI Company, Achtseweg Noord 5, Eindhoven 5600 KA (Netherlands); Borghardt, Sven; Kardynal, Beata E. [Peter Grünberg Institute 9 (PGI-9), Forschungszentrum Jülich, D-52425 Jülich (Germany); and others

    2017-07-15

    The phase and amplitude of the electron wavefunction that has passed through ultra-thin flakes of WSe{sub 2} is measured from high-resolution off-axis electron holograms. Both the experimental measurements and corresponding computer simulations are used to show that, as a result of dynamical diffraction, the spatially averaged phase does not increase linearly with specimen thickness close to an [001] zone axis orientation even when the specimen has a thickness of only a few layers. It is then not possible to infer the local specimen thickness of the WSe{sub 2} from either the phase or the amplitude alone. Instead, we show that the combined analysis of phase and amplitude from experimental measurements and simulations allows an accurate determination of the local specimen thickness. The relationship between phase and projected potential is shown to be approximately linear for extremely thin specimens that are tilted by several degrees in certain directions from the [001] zone axis. A knowledge of the specimen thickness then allows the electrostatic potential to be determined from the measured phase. By using this combined approach, we determine a value for the mean inner potential of WSe{sub 2} of 18.9±0.8 V, which is 12% lower than the value calculated from neutral atom scattering factors. - Highlights: • Quantitative analysis of high resolution electron holograms of WSe{sub 2}. • Local specimen thickness determination and estimation of tilt angle. • Mean inner potential evaluation of WSe2 avoiding dynamical diffraction.

  7. Differentiation of Metastatic and Non-Metastatic Mesenteric Lymph Nodes by Strain Elastography in Surgical Specimens

    DEFF Research Database (Denmark)

    Havre, R F; Leh, S M; Gilja, O H

    2016-01-01

    Purpose: To investigate if strain elastography could differentiate between metastatic and non-metastatic mesenteric lymph nodes ex-vivo. Materials and Methods: 90 mesenteric lymph nodes were examined shortly after resection from 25 patients including 17 patients with colorectal cancer and 8...... patients with Crohn's disease. Ultrasound-based strain elastography was performed with a linear probe. Tissue hardness in lymph nodes was assessed using visual scales and measuring the strain ratio. B-mode characteristics were also recorded. Pathological diagnosis with grading of fibrosis served...... non-metastatic nodes, but the difference was not significant (65.5 vs. 55.0, p = 0.055). There was no difference between lymph nodes in Crohn's and non-metastatic cancer specimens. The metastatic lymph nodes were significantly more fibrotic than the non-metastatic lymph nodes by the ordinal fibrosis...

  8. The measuring technique developed to evaluate the thermal diffusivity of the multi-layered thin film specimens

    Directory of Open Access Journals (Sweden)

    Li Tse-Chang

    2017-01-01

    Full Text Available In the present study, the thermal diffusivities of the Al, Si and ITO films deposited on the SUS304 steel substrate are evaluated via the present technique. Before applying this technique, the temperature for the thin film of the multi-layered specimen is developed theoretically for the one- dimensional steady heat conduction in response to amplitude and frequency of the periodically oscillating temperature imposed by a peltier placed beneath the specimen's substrate. By the thermal-electrical data processing system excluding the lock-in amplifier, the temperature frequency a3 has been proved first to be independent of the electrical voltage applied to the peltier and the contact position of the thermocouples. The experimental data of phase difference for three kinds of specimen are regressed well by a straight line with a slope. Then, the thermal diffusivity of the thin film is thus determined if the slope value and the film- thickness are available. In the present arrangements for the thermocouples, two thermal diffusivity values are quite close each other and valid for every kind of specimen. This technique can provide an efficient, low-cost method for the thermal diffusivity measurements of thin films.

  9. Thermal neutron flux measurements in the rotary specimen rack of the IPR-R1 TRIGA reactor

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Rose Mary G. do Prado; Rodrigues, Rogério R.; Souza, Luiz Claudio A., E-mail: souzarm@cdtn.br, E-mail: rrr@cdtn.br, E-mail: lcas@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    The thermal neutron flux in the rotary specimen rack of the IPR-R1 TRIGA reactor at the Nuclear Technology Development Center (CDTN), Belo Horizonte, Brazil, has been measured by the neutron activation method, using bare and cadmium covered gold foils. Those foils were irradiated in the rotary specimen rack with the reactor at 100 kW. The reactor core configuration has 63 fuel elements, composed of 59 original aluminum-clad elements and 4 stainless steel-clad fuel elements. The gamma activities of the foils were measured using Ge spectrometer. The perturbations of the thermal neutron flux caused by the introduction of an absorbing foil into the medium were considered in order to obtain accurate determination of the flux. The thermal neutron flux obtained was 7.4 x 10{sup 11} n.cm{sup -2}.s{sup -1}. (author)

  10. SU-F-J-07: Evaluating the Adequacy of Biopsy Specimens for Genetic Signature Assessment by Measuring the Metabolic Activity in Specimens Obtained Under 18F-FDG PET/CT Guidance

    Energy Technology Data Exchange (ETDEWEB)

    Fanchon, L; Russell, J; Dogan, S; Carlin, S; Pinker-Domenig, K; Yorke, E; Schmidtlein, C. Ross; Fujisawa, S; Manova-Todorova, K; Zanzonico, P; Deasy, J O; Humm, J L; Solomon, S; Kirov, A S [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: Genetic profiling of biopsied tissue is the basis for personalized cancer therapy. However biopsied materials may not contain sufficient amounts of DNA needed for analysis. We propose a method to determine the adequacy of specimens for performing genetic profiling by quantifying metabolic activity. Methods: We measured the response of two radiation detectors to the activity contained in the minimum amount of tumor cells needed for genetic profiling in biopsy specimens obtained under 2-deoxy-2-({sup 18}F)fluoro-D-glucose ({sup 18}F-FDG) PET/CT guidance. The expected tumor cell concentration in biopsy specimens was evaluated from the amount of DNA needed (∼100 µg) and the number of pathology sections typically used for the analysis. The average {sup 18}F-FDG uptake per cell was measured by incubating KPC-4662 pancreatic tumor cells and HT-29 colorectal adenocarcinoma tumor cells in {sup 18}F-FDG containing solution (activity concentrations between 0.0122 and 1.51 MBq/mL and glucose concentrations of 3.1 and 1 g/L) for 1 to 1.75 hours and then measuring the activity of a known number of cells. Measurements of surrogate specimens obtained using 18G needle biopsies of gels containing these cells in expected concentrations (∼10{sup 4} µL{sup −1}) were performed using an autoradiography CCD based device (up to 20 min exposure) and a scintillation well counter (∼1 min measurements) about 3 and 5 hours after the end of incubation respectively. Results: At start of autoradiography there were between 0.16 and 1.5 {sup 18}F-FDG molecules/cell and between 1.14 and 5.43×10{sup 7} {sup 18}F-FDG molecules/mL. For the scintillation well counter, sample to minimum-detectable-count rate ratios were greater than 7 and the counting error was less than 25% for ≤80 s measurement times. Images of the samples were identifiable on the autoradiograph for ∼10 min and longer exposure times. Conclusion: Scintillation well counter measurements and CCD based

  11. Effect of out-of-plane specimen movement on strain measurement using digital-image-correlation-based video measurement in 2D and 3D

    DEFF Research Database (Denmark)

    Poling, Joel; Desai, Niranjan; Fischer, Gregor

    2018-01-01

    This study determined the effect of specimen out-of-plane movement relative to the sensor, on the accuracy of strains measured made applying 2D and 3D measurement approaches employing the state-of-the-art digital-image-correlation (DIC)-based tool iMETRUM. DIC provides a convenient and inexpensive...

  12. High-Resolution Ultrasonography (US) of Appendiceal Specimens: Differentiation of Acute Non-perforated Appendicitis from Perforated Appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Gyo Chang; Kim, Suk; Im, Han Hyeok; Lee, Sang Jin; Yang, Seung Boo; Lee, Seung Woo; Kim, Il Young [Soonchunhyang University Gumi Hospital, Gumi (Korea, Republic of); Lee, Hae Kyung [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Kwon, Kui Hyang; Shin, Hyung Chul [Soonchunhyang University, College of Medicine, Seoul (Korea, Republic of)

    2007-09-15

    To analyze surgical specimens from patients with acute non-perforated and perforated appendicitis using high-resolution ultrasonography (US), and to correlate the US features with the pathologic findings. One hundred and six surgical appendix specimens obtained from patients with suspected acute appendicitis were evaluated. The following US features were evaluated for differentiating acute non-perforated appendicitis from perforated appendicitis: circumferential loss of the echogenic submucosal layer, disruption of the serosal layer, asymmetrical wall thickening, the sum of opposing walls {>=} 9 mm and the presence of appendicoliths. The sensitivity and specificity of the US findings for diagnosing perforated appendicitis were determined. All US features were detected significantly more often in the perforated appendicitis group of specimens. The disruption of the serosal layer was the most significant independent predictor of perforation (p < .001). The sensitivity for circumferential loss of the echogenic submucosal layer, disruption of the serosal layer, asymmetrical wall thickening, wall thickness {>=} 9 mm, and the presence of appendicoliths individually was 84.6%, 69.2%, 61.5%, 73.1% and 46.2%, respectively. The specificity for all of these findings was 86.3%, 98.7%, 95.0%, 85.0% and 85.0%, respectively. High-resolution US of appendiceal specimens was very useful for differentiating acute non-perforated from perforated appendicitis

  13. Use of 'MICROPROFILOMETER-2' in precise measurements of diameters of irradiated rod-type cylindrical specimens

    International Nuclear Information System (INIS)

    Kuprienko, M.V.; Dvoretsky, V.G.; Kubasov, E.V.; Rabinovich, A.D.

    2002-01-01

    The paper presents the basic principles of profilometer design, the imposed requirements and some problems emerged in their bringing into practice. Installation designed and made at SSC RF RIAR to precisely measure diameters of rod-type specimens is described. Some results of metrological certification of this installation are given. (author)

  14. Measurement of the Young's modulus of thin or flexible specimen with digital-image correlation method

    Science.gov (United States)

    Xu, Lianyun; Hou, Zhende; Qin, Yuwen

    2002-05-01

    Because some composite material, thin film material, and biomaterial, are very thin and some of them are flexible, the classical methods for measuring their Young's moduli, by mounting extensometers on specimens, are not available. A bi-image method based on image correlation for measuring Young's moduli is developed in this paper. The measuring precision achieved is one order enhanced with general digital image correlation or called single image method. By this way, the Young's modulus of a SS301 stainless steel thin tape, with thickness 0.067mm, is measured, and the moduli of polyester fiber films, a kind of flexible sheet with thickness 0.25 mm, are also measured.

  15. Measurement of blood flow through surgical anastomosis using the radioactive microsphere technique

    Energy Technology Data Exchange (ETDEWEB)

    Hummel, S.J.; Delgado, G.; Butterfield, A.; Dritschilo, A.; Harbert, J.

    1985-10-01

    Two different radioactive microspheres ( U Ce and UWSc) were used to measure blood flow to an area of the large intestine in dogs before and after a surgical resection was performed with surgical staples. The healing of an anastomosis is theoretically related to the blood flow to the anastomotic site. Blood flow studies were conducted in three dogs using this technique. The average blood flow preoperatively was 0.558 mL/minute per gram and 1.04 mL/minute per gram postoperatively. These results indicate a statistically significant increase in blood flow at the anastomotic site six days after anastomosis when compared with the blood flow to the same area before any surgical procedures.

  16. Measurement of blood flow through surgical anastomosis using the radioactive microsphere technique

    International Nuclear Information System (INIS)

    Hummel, S.J.; Delgado, G.; Butterfield, A.; Dritschilo, A.; Harbert, J.

    1985-01-01

    Two different radioactive microspheres ( 141 Ce and 46 Sc) were used to measure blood flow to an area of the large intestine in dogs before and after a surgical resection was performed with surgical staples. The healing of an anastomosis is theoretically related to the blood flow to the anastomotic site. Blood flow studies were conducted in three dogs using this technique. The average blood flow preoperatively was 0.558 mL/minute per gram and 1.04 mL/minute per gram postoperatively. These results indicate a statistically significant increase in blood flow at the anastomotic site six days after anastomosis when compared with the blood flow to the same area before any surgical procedures

  17. Prostate volume measurement by TRUS using heights obtained by transaxial and midsagittal scaning: comparison with specimen volume following radical prostatectomy

    International Nuclear Information System (INIS)

    Park, Bung Bin; Kim, Jae Kyun; Choi, Sung Hoon; Noh, Han Na; Ji, Eun Kyung; Cho, Kyoung Sik

    2000-01-01

    The purpose of this study was to determine, when measuring prostate volume by TRUS, whether height is more accurately determined by transaxial or midsagittal scanning. Sixteen patients who between March 1995 and March 1998 underwent both preoperative TRUS and radical prostatectomy for prostate cancer were included in this study. Using prolate ellipse volume calculation (height x length x width x π/6), TRUS prostate volume was determined, and was compared with the measured volume of the specimen. Prostate volume measured by TRUS, regardless of whether height was determined transaxially or midsagittally, correlated closely with real specimen volume. When height was measured in one of these planes, a paired t test revealed no significant difference between TRUS prostate volume and real specimen volume (p = .411 and p = .740, respectively), nor were there significant differences between the findings of transaxial and midsagittal scanning (p = .570). A paired sample test, however, indicated that TRUS prostate volumes determined transaxially showed a higher correlation coefficient (0.833) and a lower standard deviation (9.04) than those determined midsagittally (0.714 and 11.48, respectively). Prostate volume measured by TRUS closely correlates with real prostate volume. Furthermore, we suggest that when measuring prostate volume in this way, height is more accurately determined by transaxial than by midsagittal scanning

  18. Comparison of immersion density and improved microstructural characterization methods for measuring swelling in small irradiated disk specimens

    International Nuclear Information System (INIS)

    Sawai, T.; Suzuki, M.; Hishinuma, A.; Maziasz, P.J.

    1992-01-01

    The procedure of obtaining microstructural data from reactor-irradiated specimens has been carefully checked for accuracy by comparison of swelling data obtained from transmission electron microscopy (TEM) observations of cavities with density-change data measured using the Precision Densitometer at Oak Ridge National Laboratory (ORNL). Comparison of data measured by both methods on duplicate or, in some cases, on the same specimen has shown some appreciable discrepancies for US/Japan collaborative experiments irradiated in the High Flux Isotope Reactor (HFIR). The contamination spot separation (CSS) method was used in the past to determine the thickness of a TEM foil. Recent work has revealed an appreciable error in this method that can result in an overestimation of the foil thickness. This error causes lower swelling values to be measured by TEM microstructural observation relative to the Precision Densitometer. An improved method is proposed for determining the foil thickness by the CSS method, which includes a correction for the systematic overestimation of foil thickness. (orig.)

  19. [Usefullness of intraoperatory parathyroid hormone measurement in surgical management of primary hyperparathyroidism due to a parathyroid adenoma].

    Science.gov (United States)

    Obiols, Gabriel; Catalán, Roberto; Alasà, Cristian; Baena, Juan Antonio; Fort, José Manuel; Gémar, Enrique; Mesa, Jordi

    2003-09-13

    Surgical neck exploration of the 4 parathyroid glands is quite an aggressive procedure for most patients with primary hyperparathyroidism (PHPT) due to a parathyroid adenoma. Intraoperatory measurement of parathyroid hormone (PTH) seems to be a useful tool for the management of these cases, allowing the use of minimally invasive surgical techniques with a lower morbidity. Our aims was to assess the usefulness of PTH intraoperatory measurement for the surgical management of PHPT. We studied 27 consecutive patients, diagnosed with PHPT secondary to parathyroid adenoma. Localization studies included neck ultrasonography and Tc-MIBI scintigraphy. PTH at the stage of anesthesia induction as well as 5 and 10 minutes after the removal of the adenoma was determined. A PTH decrement greater than 50% at 10 minutes was considered as curative. PTH was measured by an immunoluminometric method (Advantage, Nichols). In all cases, calcium levels were normal 24 hours after the operation, and therefore all them were considered as cured. PTH levels decreased more than 50% in all patients. In one case, PTH levels remained high after the exeresis of a preoperatively localized lesion. The pathologic study confirmed that it was a normal parathyroid gland. We then continued the surgical exploration which eventually allowed us to find a contralateral adenoma. A further PTH measurement showed an over 50% decrease. Therefore, PTH was predictive of surgical success in all 28 measurements. Intraoperatory determination of PTH is useful for the surgical management of PHPT and it could allow the use of minimally invasive surgical techniques.

  20. Application of a uniform anatomic grading system to measure disease severity in eight emergency general surgical illnesses.

    Science.gov (United States)

    Crandall, Marie L; Agarwal, Suresh; Muskat, Peter; Ross, Steven; Savage, Stephanie; Schuster, Kevin; Tominaga, Gail T; Shafi, Shahid

    2014-11-01

    Emergent general surgical diseases encompass a broad spectrum of anatomy and pathophysiology, creating challenges for outcomes assessment, research, and surgical training. The goal of this study was to measure anatomic disease severity for eight emergent general surgical diseases using the uniform grading system of the American Association for the Surgery of Trauma (AAST). The Committee on Patient Assessment and Outcomes of AAST applied the previously developed uniform grading system to eight emergent general surgical diseases using a consensus of experts. It was then reviewed and approved by the Board of Managers of AAST. Severity grades for eight commonly encountered emergent general surgical conditions were created: breast abscess, esophageal perforation, infectious colitis, pelvic inflammatory disease, perirectal abscess, pleural space infections, soft tissue infections, and surgical site infections. The range of grades from I through V, reflect progression from mild disease, limited to within the organ itself, to widespread severe disease. This article provides a uniform grading system for measuring anatomic severity of eight emergent general surgical diseases. Consistent adoption of these grades could improve standardization for quality assurance, outcomes research, and surgical training.

  1. Patient identification error among prostate needle core biopsy specimens--are we ready for a DNA time-out?

    Science.gov (United States)

    Suba, Eric J; Pfeifer, John D; Raab, Stephen S

    2007-10-01

    Patient identification errors in surgical pathology often involve switches of prostate or breast needle core biopsy specimens among patients. We assessed strategies for decreasing the occurrence of these uncommon and yet potentially catastrophic events. Root cause analyses were performed following 3 cases of patient identification error involving prostate needle core biopsy specimens. Patient identification errors in surgical pathology result from slips and lapses of automatic human action that may occur at numerous steps during pre-laboratory, laboratory and post-laboratory work flow processes. Patient identification errors among prostate needle biopsies may be difficult to entirely prevent through the optimization of work flow processes. A DNA time-out, whereby DNA polymorphic microsatellite analysis is used to confirm patient identification before radiation therapy or radical surgery, may eliminate patient identification errors among needle biopsies.

  2. Differential contributions of specimen types, culturing, and 16S rRNA sequencing in diagnosis of prosthetic joint infections

    DEFF Research Database (Denmark)

    Larsen, Lone Heimann; Khalid, Vesal; Xu, Yijuan

    2018-01-01

    to variations in specimen sampling. In this prospective, multidisciplinary study of hip or knee prosthetic failures, we assessed the contributions of different specimen types, extended culture incubations, and 16S rRNA sequencing for diagnosing prosthetic joint infections (PJI). Project specimens included joint...... fluid (JF), bone biopsy specimens (BB), soft-tissue biopsy specimens (STB), and swabs (SW) from the prosthesis, collected in situ, and sonication fluid collected from prosthetic components (PC). Specimens were cultured for 6 (conventional) or 14 days, and 16S rRNA sequencing was performed at study...... completion. Of the 156 patients enrolled, 111 underwent 114 surgical revisions (cases) due to indications of either PJI (n = 43) or AF (n = 71). Conventional tissue biopsy cultures confirmed PJI in 28/43 (65%) cases and refuted AF in 3/71 (4%) cases; one case was not evaluable. Based on these results, minor...

  3. Imaging of concrete specimens using inverse synthetic aperture radar

    International Nuclear Information System (INIS)

    Rhim, Hong C.; Buyukozturk, Oral

    2000-01-01

    Radar Measurement results of laboratory size concrete specimens are presented in this paper. The purpose of this research work is to study various aspects of the radar method in an effort to develop an improved radar system for nondestructive testing of concrete structures. The radar system used for the study is an Inverse Synthetic Aperture Radar (ISAR), which is capable of transmitting microwaves at three different frequency ranges of 2-3.4, 3.4-5.8, and 8-12 GHz. Radar measurement setup is such that the radar is locates 14.4 m away from a concrete target to satisfy a far-field criterion. The concrete target is rotated for 20 degrees during the measurements for the generation of two-dimensional (cross-range) imagery. Concrete targets used for the measurements have the dimensions of 305 mm (width)x305 mm (height)x92 mm (thickness) with different inside configurations. Comparisons are made for dry and wet specimens, specimens with and without inclusions. Each specimen is made to model various situations that a concrete structure can have in reality. Results show that center frequency, frequency bandwidth, and polarization of the incident wave have different effects on identifying the thickness or inclusions inside concrete specimens. Results also suggest that a certain combination of measurement parameters is suitable for a specific application area. Thus, measurement parameters can be optimized for a specific problem. The findings are presented and discussed in details in the paper. Signal processing schemes implemented for imaging of the specimens are also discussed

  4. Synchrotron radiation microprobe quantitative analysis method for biomedical specimens

    International Nuclear Information System (INIS)

    Xu Qing; Shao Hanru

    1994-01-01

    Relative changes of trace elemental content in biomedical specimens are obtained easily by means of synchrotron radiation X-ray fluorescence microprobe analysis (SXRFM). However, the accurate assignment of concentration on a g/g basis is difficult. Because it is necessary to know both the trace elemental content and the specimen mass in the irradiated volume simultaneously. the specimen mass is a function of the spatial position and can not be weighed. It is possible to measure the specimen mass indirectly by measuring the intensity of Compton scattered peak for normal XRF analysis using a X-ray tube with Mo anode, if the matrix was consisted of light elements and the specimen was a thin sample. The Compton peak is not presented in fluorescence spectrum for white light SXRFM analysis. The continuous background in the spectrum was resulted from the Compton scattering with a linear polarization X-ray source. Biomedical specimens for SXRFM analysis, for example biological section and human hair, are always a thin sample for high energy X-ray, and they consist of H,C,N and O etc. light elements, which implies a linear relationship between the specimen mass and the Compton scattering background in the high energy region of spectrum. By this way , it is possible to carry out measurement of concentration for SXRFM analysis

  5. Measuring patient participation in surgical treatment decision-making from healthcare professionals' perspective.

    Science.gov (United States)

    Heggland, Liv-Helen; Mikkelsen, Aslaug; Øgaard, Torvald; Hausken, Kjell

    2014-02-01

    To develop, empirical test, and validate an instrument measuring patient participation in surgical treatment decision-making from healthcare professionals' perspective. Since the advent of New Public Management in many Western countries, patient participation in healthcare decision-making has been considered to be a best practice. A common notion is that well-educated and well-informed public want to choose their own treatments and providers and want to ask questions about the quality of their health services. Survey. A self-report-measuring instrument was designed and administered to 620 healthcare professionals. Items were developed, validated and tested by 451 nurses and physicians working in six surgical wards in a University Hospital in Norway. A 16-item scale with the following four dimensions was developed: information dissemination, formulation of options, integration of information and control. Factor analysis procedures and reliability testing were performed. A one-way, between-groups analysis of variance was conducted to compare doctors' and nurses' opinions on four dimensions of patient participation in surgical treatment decision-making. This article shows that patient participation in surgical treatment decision-making can be measured by a 16-item scale and four distinct dimensions. The analysis demonstrated a reasonable level of construct validity and reliability. Nurses and physicians have a positive attitude towards patient participation overall, but the two groups differ in the extent to which they accept the idea of patient participation in treatment decision-making. The instrument can be a tool for managers and healthcare professionals in the implementation of patient participation in clinical practice. Data from the instrument can be useful to identify health services being provided and what areas that could strengthen patient participation. © 2013 Blackwell Publishing Ltd.

  6. Selection of oncoplastic surgical technique in Asian breast cancer patients

    Directory of Open Access Journals (Sweden)

    Eui Sun Shin

    2018-01-01

    Full Text Available Background Oncoplastic surgery is being increasingly performed in Korean women; however, unlike Westerners, Korean women usually have small to moderate-sized breasts. To achieve better outcomes in reconstructed breasts, several factors should be considered to determine the optimal surgical method. Methods A total of 108 patients who underwent oncoplastic surgery from January 2013 to December 2016 were retrospectively investigated. We used various methods, including glandular tissue reshaping, latissimus dorsi (LD flap transposition, and reduction oncoplasty, to restore the breast volume and symmetry. Results The mean weight of the tumor specimens was 40.46 g, and the ratio of the tumor specimen weight to breast volume was 0.12 g/mL in the patients who underwent glandular tissue reshaping (n=59. The corresponding values were 101.47 g and 0.14 g/mL, respectively, in the patients who underwent reduction oncoplasty (n=17, and 82.54 g and 0.20 g/mL, respectively, in those treated with an LD flap (n=32. Glandular tissue reshaping was mostly performed in the upper outer quadrant, and LD flap transposition was mostly performed in the lower inner quadrant. No major complications were noted. Most patients were satisfied with the aesthetic results. Conclusions We report satisfactory outcomes of oncoplastic surgical procedures in Korean patients. The results regarding specimen weight and the tumor-to-breast ratio of Asian patients will be a helpful reference point for determining the most appropriate oncoplastic surgical technique.

  7. Improving the quality of colon cancer surgery through a surgical education program

    DEFF Research Database (Denmark)

    West, Nicholas P; Sutton, Kate M; Ingeholm, Peter

    2010-01-01

    Recent evidence has demonstrated the importance of dissection in the correct tissue plane for the resection of colon cancer. We have previously shown that meticulous mesocolic plane surgery yields better outcomes and that the addition of central vascular ligation produces an oncologically superio...... specimen compared with standard techniques. We aimed to assess the effect of surgical education on the oncological quality of the resection specimen produced....

  8. Birth and death of human β-cells in pancreas from cadaver donors, autopsies, surgical specimens, and islets transplanted into mice

    Science.gov (United States)

    Caballero, Francisco; Siniakowicz, Karolina; Jennifer-Hollister-Lock; Duran, Luisa; Katsuta, Hitoshi; Yamada, Takatsugu; Lei, Ji; Deng, Shaoping; Westermark, Gunilla T.; Markmann, James; Bonner-Weir, Susan; Weir, Gordon C.

    2013-01-01

    There is great interest in the potential of the human endocrine pancreas for regeneration by β-cell replication or neogenesis. Our aim was to explore this potential in adult human pancreases and in both islet and exocrine tissue transplanted into mice. The design was to examine pancreases obtained from cadaver donors, autopsies and fresh surgical specimens and compare these findings with those obtained from islet and duct tissue grafted into the kidney. Islets and exocrine tissue were transplanted into normoglycemic ICR/SCID mice and studied 4 and 14 wk later. β-cell replication as assessed by double staining for insulin and Ki67 was 0.22 ± 0.03 % at 4 wk and 0.13 ± 0.03 % at 14 wk. In contrast, no evidence of β-cell replication could be found in 11 cadaver donor and 10 autopsy pancreases. However, Ki67 staining of β-cells in frozen sections obtained at surgery was comparable to that found in transplanted islets. Evidence for neogenesis in transplanted pancreatic exocrine tissue was supported by finding β-cells within the duct epithelium, and the presence of cells double stained for insulin and cytokeratin 19 (CK19). However, β-cells within the ducts never constituted more than 1% of the CK19 positive cells. With confocal microscopy, 7 of 12 examined cells expressed both markers, consistent with a neogeneic process. Mice with grafts containing islet or exocrine tissue were treated with various combinations exendin-4, gastrin and epidermal growth factor; none increased β-cell replication or stimulated neogenesis. In summary, human β-cells replicate at a low level in islets transplanted into mice and in surgical pancreatic frozen sections but rarely in cadaver donor or autopsy pancreases. The absence of β-cell replication in many adult cadaver or autopsy pancreases could, in part, be an artifact of the postmortem state. Thus, it appears that adult human β-cells maintain a low level of turnover through replication and neogenesis. PMID:23321263

  9. Birth and death of human β-cells in pancreases from cadaver donors, autopsies, surgical specimens, and islets transplanted into mice.

    Science.gov (United States)

    Caballero, Francisco; Siniakowicz, Karolina; Hollister-Lock, Jennifer; Duran, Luisa; Katsuta, Hitoshi; Yamada, Takatsugu; Lei, Ji; Deng, Shaoping; Westermark, Gunilla T; Markmann, James; Bonner-Weir, Susan; Weir, Gordon C

    2014-02-01

    There is great interest in the potential of the human endocrine pancreas for regeneration by β-cell replication or neogenesis. Our aim was to explore this potential in adult human pancreases and in both islet and exocrine tissue transplanted into mice. The design was to examine pancreases obtained from cadaver donors, autopsies, and fresh surgical specimens and compare these findings with those obtained from islet and duct tissue grafted into the kidney. Islets and exocrine tissue were transplanted into normoglycemic ICR-SCID mice and studied 4 and 14 weeks later. β-Cell replication, as assessed by double staining for insulin and Ki67, was 0.22 ± 0.03% at 4 weeks and 0.13 ± 0.03% at 14 weeks. In contrast, no evidence of β-cell replication could be found in 11 cadaver donor and 10 autopsy pancreases. However, Ki67 staining of β-cells in frozen sections obtained at surgery was comparable to that found in transplanted islets. Evidence for neogenesis in transplanted pancreatic exocrine tissue was supported by finding β-cells within the duct epithelium and the presence of cells double stained for insulin and cytokeratin 19 (CK19). However, β-cells within the ducts never constituted more than 1% of the CK19-positive cells. With confocal microscopy, 7 of 12 examined cells expressed both markers, consistent with a neogeneic process. Mice with grafts containing islet or exocrine tissue were treated with various combinations of exendin-4, gastrin, and epidermal growth factor; none increased β-cell replication or stimulated neogenesis. In summary, human β-cells replicate at a low level in islets transplanted into mice and in surgical pancreatic frozen sections, but rarely in cadaver donor or autopsy pancreases. The absence of β-cell replication in many adult cadaver or autopsy pancreases could, in part, be an artifact of the postmortem state. Thus, it appears that adult human β-cells maintain a low level of turnover through replication and neogenesis.

  10. CT- and MRI-based volumetry of resected liver specimen: Comparison to intraoperative volume and weight measurements and calculation of conversion factors

    International Nuclear Information System (INIS)

    Karlo, C.; Reiner, C.S.; Stolzmann, P.; Breitenstein, S.; Marincek, B.; Weishaupt, D.; Frauenfelder, T.

    2010-01-01

    Objective: To compare virtual volume to intraoperative volume and weight measurements of resected liver specimen and calculate appropriate conversion factors to reach better correlation. Methods: Preoperative (CT-group, n = 30; MRI-group, n = 30) and postoperative MRI (n = 60) imaging was performed in 60 patients undergoing partial liver resection. Intraoperative volume and weight of the resected liver specimen was measured. Virtual volume measurements were performed by two readers (R1,R2) using dedicated software. Conversion factors were calculated. Results: Mean intraoperative resection weight/volume: CT: 855 g/852 mL; MRI: 872 g/860 mL. Virtual resection volume: CT: 960 mL(R1), 982 mL(R2); MRI: 1112 mL(R1), 1115 mL(R2). Strong positive correlation for both readers between intraoperative and virtual measurements, mean of both readers: CT: R = 0.88(volume), R = 0.89(weight); MRI: R = 0.95(volume), R = 0.92(weight). Conversion factors: 0.85(CT), 0.78(MRI). Conclusion: CT- or MRI-based volumetry of resected liver specimen is accurate and recommended for preoperative planning. A conversion of the result is necessary to improve intraoperative and virtual measurement correlation. We found 0.85 for CT- and 0.78 for MRI-based volumetry the most appropriate conversion factors.

  11. Monolithic integration of nanoscale tensile specimens and MEMS structures

    International Nuclear Information System (INIS)

    Yilmaz, Mehmet; Kysar, Jeffrey W

    2013-01-01

    Nanoscale materials often have stochastic material properties due to a random distribution of material defects and an insufficient number of defects to ensure a consistent average mechanical response. Current methods to measure the mechanical properties employ MEMS-based actuators. The nanoscale specimens are typically mounted manually onto the load platform, so the boundary conditions have random variations, complicating the experimental measurement of the intrinsic stochasticity of the material properties. Here we show methods for monolithic integration of a nanoscale specimen co-fabricated with the loading platform. The nanoscale specimen is gold with dimensions of ∼40 nm thickness, 350 ± 50 nm width, and 7 μm length and the loading platform is an interdigitated electrode electrostatic actuator. The experiment is performed in a scanning electron microscope and digital image correlation is employed to measure displacements to determine stress and strain. The ultimate tensile strength of the nanocrystalline nanoscale specimen approaches 1 GPa, consistent with measurements made by other nanometer scale sample characterization methods on other material samples at the nanometer scale, as well as gold samples at the nanometer scale. The batch-compatible microfabrication method can be used to create nominally identical nanoscale specimens and boundary conditions for a broad range of materials. (paper)

  12. Diagnostic p53 immunostaining of endobiliary brush cytology: preoperative cytology compared with the surgical specimen

    NARCIS (Netherlands)

    Tascilar, M.; Sturm, P. D.; Caspers, E.; Smit, M.; Polak, M. M.; Huibregtse, K.; Noorduyn, L. A.; Offerhaus, G. J.

    1999-01-01

    Endobiliary brush cytology is important in the distinction of malignant and benign causes of extrahepatic bile duct obstruction. The additional diagnostic value of p53 immunostaining on these cytology specimens was assessed. All patients with extrahepatic bile duct obstruction who underwent

  13. Preliminary investigation of candidate specimens for the Egyptian environmental specimen bank

    International Nuclear Information System (INIS)

    Shawky, S.; Amer, H.; Schladot, J.D.; Ostapczuk, P.; Emons, H.; Abou El-Nour, F.

    2000-01-01

    In the frame of establishing an environmental monitoring program related to environmental specimen banking in egypt, some candidate specimens from the aquatic environment (Fish muscle, fish liver; mussels) were investigated. The selection of specimens and sampling sites is described. Specimens are chemically characterised with respect to some major and trace elements and the results are compared with data obtained from comparable specimens collected in aquatic ecosystems of germany

  14. Laparoscopic right-sided colonic resection with transluminal colonoscopic specimen extraction

    Science.gov (United States)

    Kayaalp, Cuneyt; Kutluturk, Koray; Yagci, Mehmet Ali; Ates, Mustafa

    2015-01-01

    AIM: To study the transcolonic extraction of the proximally resected colonic specimens by colonoscopic assistance at laparoscopic colonic surgery. METHODS: The diagnoses of our patients were Crohn’s disease, carcinoid of appendix and adenocarcinoma of cecum. We preferred laparoscopic total mesocolic resections. Colon and terminal ileum were divided with endoscopic staplers. A colonoscope was placed per anal and moved proximally in the colon till to reach the colonic closed end under the laparoscopic guidance. The stump of the colon was opened with laparoscopic scissors. A snare of colonoscope was released and the intraperitoneal complete free colonic specimen was grasped. Specimen was moved in to the colon with the help of the laparoscopic graspers and pulled gently through the large bowel and extracted through the anus. The open end of the colon was closed again and the ileal limb and the colon were anastomosed intracorporeally with a 60-mm laparoscopic stapler. The common enterotomy orifice was closed in two layers with a running intracorporeal suture. RESULTS: There were three patients with laparoscopic right-sided colonic resections and their specimens were intended to remove through the remnant colon by colonoscopy but the procedure failed in one patient (adenocarcinoma) due to a bulky mass and the specimen extraction was converted to transvaginal route. All the patients had prior abdominal surgeries and had related adhesions. The operating times were 210, 300 and 500 min. The lengths of the specimens were 13, 17 and 27 cm. In our cases, there were no superficial or deep surgical site infections or any other complications. The patients were discharged uneventfully within 4-5 d and they were asymptomatic after a mean 7.6 mo follow-up (ranged 4-12). As far as we know, there were only 12 cases reported yet on transcolonic extraction of the proximal colonic specimens by colonoscopic assistance after laparoscopic resections. With our cases, success rate of the

  15. AGC-2 Specimen Post Irradiation Data Package Report

    Energy Technology Data Exchange (ETDEWEB)

    Windes, William Enoch [Idaho National Lab. (INL), Idaho Falls, ID (United States); Swank, W. David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rohrbaugh, David T. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Cottle, David L. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-08-01

    This report documents results of the post-irradiation examination material property testing of the creep, control, and piggyback specimens from the irradiation creep capsule Advanced Graphite Creep (AGC)-2 are reported. This is the second of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades. The AGC-2 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 600°C and to a peak dose of 5 dpa (displacements per atom). One-half of the creep specimens were subjected to mechanical stresses (an applied stress of either 13.8, 17.2, or 20.7 MPa) to induce irradiation creep. All post-irradiation testing and measurement results are reported with the exception of the irradiation mechanical strength testing, which is the last destructive testing stage of the irradiation testing program. Material property tests were conducted on specimens from 15 nuclear graphite grades using a similar loading configuration as the first AGC capsule (AGC-1) to provide easy comparison between the two capsules. However, AGC-2 contained an increased number of specimens (i.e., 487 total specimens irradiated) and replaced specimens of the minor grade 2020 with the newer grade 2114. The data reported include specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and volume data necessary to derive density, elastic constants (Young’s modulus, shear modulus, and Poisson’s ratio) from ultrasonic time-of-flight velocity measurements, Young’s modulus from the fundamental frequency of vibration, electrical resistivity, and thermal diffusivity and thermal expansion data from 100–500°C. No data outliers were determined after all measurements were completed. A brief statistical analysis was performed on the irradiated data and a limited comparison between

  16. Biobanking of fresh frozen tissue from clinical surgical specimens: transport logistics, sample selection, and histologic characterization.

    Science.gov (United States)

    Botling, Johan; Micke, Patrick

    2011-01-01

    Access to high-quality fresh frozen tissue is critical for translational cancer research and molecular -diagnostics. Here we describe a workflow for the collection of frozen solid tissue samples derived from fresh human patient specimens after surgery. The routines have been in operation at Uppsala University Hospital since 2001. We have integrated cryosection and histopathologic examination of each biobank sample into the biobank manual. In this way, even small, macroscopically ill-defined lesions can be -procured without a diagnostic hazard due to the removal of uncharacterized tissue from a clinical -specimen. Also, knowledge of the histomorphology of the frozen tissue sample - tumor cell content, stromal components, and presence of necrosis - is pivotal before entering a biobank case into costly molecular profiling studies.

  17. Grips for testing of electrical characteristics of a specimen under a mechanical load

    Science.gov (United States)

    Briggs, Timothy; Loyola, Bryan

    2018-04-24

    Various technologies to facilitate coupled electrical and mechanical measurement of conductive materials are disclosed herein. A gripping device simultaneously holds a specimen in place and causes contact to be made between the specimen and a plurality of electrodes connected to an electrical measuring device. An electrical characteristic of the specimen is then measured while a mechanical load is applied to the specimen, and a relationship between the mechanical load and changes in the electrical characteristic can be identified.

  18. Impact of specimen adequacy on the assessment of renal allograft biopsy specimens.

    Science.gov (United States)

    Cimen, S; Geldenhuys, L; Guler, S; Imamoglu, A; Molinari, M

    2016-01-01

    The Banff classification was introduced to achieve uniformity in the assessment of renal allograft biopsies. The primary aim of this study was to evaluate the impact of specimen adequacy on the Banff classification. All renal allograft biopsies obtained between July 2010 and June 2012 for suspicion of acute rejection were included. Pre-biopsy clinical data on suspected diagnosis and time from renal transplantation were provided to a nephropathologist who was blinded to the original pathological report. Second pathological readings were compared with the original to assess agreement stratified by specimen adequacy. Cohen's kappa test and Fisher's exact test were used for statistical analyses. Forty-nine specimens were reviewed. Among these specimens, 81.6% were classified as adequate, 6.12% as minimal, and 12.24% as unsatisfactory. The agreement analysis among the first and second readings revealed a kappa value of 0.97. Full agreement between readings was found in 75% of the adequate specimens, 66.7 and 50% for minimal and unsatisfactory specimens, respectively. There was no agreement between readings in 5% of the adequate specimens and 16.7% of the unsatisfactory specimens. For the entire sample full agreement was found in 71.4%, partial agreement in 20.4% and no agreement in 8.2% of the specimens. Statistical analysis using Fisher's exact test yielded a P value above 0.25 showing that - probably due to small sample size - the results were not statistically significant. Specimen adequacy may be a determinant of a diagnostic agreement in renal allograft specimen assessment. While additional studies including larger case numbers are required to further delineate the impact of specimen adequacy on the reliability of histopathological assessments, specimen quality must be considered during clinical decision making while dealing with biopsy reports based on minimal or unsatisfactory specimens.

  19. Detection of micro calcifications in breast specimen by 4-fold DIMA direct magnification radiography compared to 1.5-fold conventional magnification radiography

    International Nuclear Information System (INIS)

    Grunert, J.H.; Borchert, B.; Farber, A.; Gmelin, E.

    1999-01-01

    Aims of the study: The purpose of this study was to investigate the efficacy of 4-fold magnification breast specimen radiography (direct magnification, DIMA) compared to conventional 1.5-fold magnification radiography in evaluating the presence of absence of carcinoma at the surgical margins by detection of microcalcification. Results: In 50 specimen 2821 (1305 within 3 mm distance to the margins) microcalcifications were detected with the DIMA mammography technique compared to 1608 (446) microcalcifications with the conventional technique. This increased detection rate by DIMA-magnetification radiography was accompanied by a decreased specificity in comparison to the conventional magnification radiography (33,3% DIMA versus 83,3% conventional) regarding the evaluation of presence or absence of carcinoma at the surgical margins. Differentiating the microcalcifications into calcifications belonging to the suspicious cluster and those that are located outside the cluster led to an increase in specificity (83,3% DIMA versus 100% conventional). Conclusions: The efficacy of breast specimens radiography in evaluating the presence or absence of carcinoma at the surgical margins by detection of microcalcification is not improved by 4-fold magnification radiography (direct magnification, DIMA) compared to conventional 1.5-fold magnification radiography due to an increase in false-positive results. Analysis of the attachement of the microcalcifications to the cluster can improve the specificity. (orig.) [de

  20. Estimation of stress distribution in ferromagnetic tensile specimens using low cost eddy current stress measurement system and BP neural network.

    Science.gov (United States)

    Li, Jianwei; Zhang, Weimin; Zeng, Weiqin; Chen, Guolong; Qiu, Zhongchao; Cao, Xinyuan; Gao, Xuanyi

    2017-01-01

    Estimation of the stress distribution in ferromagnetic components is very important for evaluating the working status of mechanical equipment and implementing preventive maintenance. Eddy current testing technology is a promising method in this field because of its advantages of safety, no need of coupling agent, etc. In order to reduce the cost of eddy current stress measurement system, and obtain the stress distribution in ferromagnetic materials without scanning, a low cost eddy current stress measurement system based on Archimedes spiral planar coil was established, and a method based on BP neural network to obtain the stress distribution using the stress of several discrete test points was proposed. To verify the performance of the developed test system and the validity of the proposed method, experiment was implemented using structural steel (Q235) specimens. Standard curves of sensors at each test point were achieved, the calibrated data were used to establish the BP neural network model for approximating the stress variation on the specimen surface, and the stress distribution curve of the specimen was obtained by interpolating with the established model. The results show that there is a good linear relationship between the change of signal modulus and the stress in most elastic range of the specimen, and the established system can detect the change in stress with a theoretical average sensitivity of -0.4228 mV/MPa. The obtained stress distribution curve is well consonant with the theoretical analysis result. At last, possible causes and improving methods of problems appeared in the results were discussed. This research has important significance for reducing the cost of eddy current stress measurement system, and advancing the engineering application of eddy current stress testing.

  1. A test specimen for characterizing the fracture energy of interfaces in composites

    International Nuclear Information System (INIS)

    Shaw, L.; Abbaschian, R.

    1993-01-01

    A sandwich-type chevron-notched specimen, which has a phase angle of loading near zero, is proposed to measure interfacial fracture energy arising mainly from chemical bonding. With the specimen configuration of this kind, the advantages from both sandwich test specimens and chevron-notched specimens can be combined to provide an easy and accurate test for the measurement of interfacial fracture energy. The validity of the specimen has been analyzed in terms of the mechanics of sandwich-type specimens and chevron-notched specimens, and demonstrated using the Al 2 O 3 /Nb bimaterial system. The results show that for a phase angle of loading around -7 degrees the Al 2 O 3 /Nb interface has a fracture energy of 9.3 ± 0.2 J/m 2 . 39 refs

  2. Pilot study of intraoperative digital imaging with the use of a mammograph for assessment of bone surgical margins in the head and neck region

    International Nuclear Information System (INIS)

    Ntomouchtsis, A.; Xinou, K.; Patrikidou, A.; Paraskevopoulos, K.; Kechagias, N.; Tsekos, A.; Balis, G.C.; Gerasimidou, D.; Thuau, H.; Mangoudi, D.; Vahtsevanos, K.

    2013-01-01

    Aim: To investigate alternative possibilities for the intraoperative evaluation of surgical margins after bone resection utilizing more conventional hospital infrastructure technologies. Materials and methods: A small pilot study was performed using digital mammograph imaging intraoperatively on 16 surgical specimens of bone tumours or malignancies with bone infiltration of the head and neck area, with the aim of evaluating the resection margins. Results: In thirteen cases the intraoperative specimen images indicated clinically complete excision. In two cases incomplete resection or close proximity of margins was detected, which required additional resection. Conclusions: The results indicated that intraoperative specimen radiography can prove useful in evaluating completeness of excision. The significance of intraoperative assessment of surgical margin is of paramount importance when immediate reconstruction is performed. This proposed method is cheap, easy to perform and fast. Its cost–benefit ratio is superior than that of any other available technique. Intraoperative analysis of specimens with digital mammography imaging can potentially become a useful tool for immediate evaluation of osseous margins after resection

  3. Assessment of Educational Environment of Surgical Theatre at a Teaching Hospital of a Saudi University: Using Surgical Theatre Educational Environment Measures

    Directory of Open Access Journals (Sweden)

    Mona Faisal Al-Qahtani

    2012-05-01

    Full Text Available Objectives: This study was aimed to determine how medical interns perceive the important factors of the learning environment the surgical theatre at the teaching hospital of the medical school, University of Dammam (UoD. The study also investigated the relationships between the learning environment and academic achievements. Finally, it determined the role and significance of gender on the above perceptions and relationships.Methods: The Surgical Theatre Educational Environment Measure (STEEM was used to identify the perceptions of interns on the most important factors prevalent in the surgical theatre as an educational environment. STEEM was administered to all interns during the period of June-September 2009. Ninety-one out of 145 students completed the questionnaire representing a response rate of 63%. Non-parametric statistical analysis was performed using Statistical Package for the Social Sciences (SPSS Version 17.Results: The STEEM was shown to be internally consistent for the assessment of the overall educational environment in the surgical theatre of UoD. The overall STEEM mean score was 110. For male and female students, the mean scores were 114 and 107 respectively. There were statistically significant gender differences in the perceptions of "learning opportunities" and "teaching and training". Females rated these subscales lower than males. There were no significant associations between academic achievements and perceptions of the educational environment.Conclusion: The interns perceived the learning environment of the surgical theatre as less than satisfactory. In comparison with the males; the perception of the females was less positive, particularly in the areas of learning opportunities, and teaching and training. The study also revealed some other problematic areas in the learning environment of surgical theatre of the teaching hospital of UoD. The results imply that there is much room for improvement. They also indicate that

  4. Surgical management of hyperthyroidism.

    Science.gov (United States)

    Quérat, C; Germain, N; Dumollard, J-M; Estour, B; Peoc'h, M; Prades, J-M

    2015-04-01

    Hyperthyroidism includes several clinical and histopathological situations. Surgery is commonly indicated after failure of medical treatment. The aim of this study was to analyze the indications and complications of surgery as well as endocrine results. Patients operated on for hyperthyroidism between 2004 and 2012 were included in a retrospective study. Total thyroidectomy was performed for Graves' disease, toxic multinodular goiter and amiodarone-associated thyrotoxicosis; patients with toxic nodule underwent hemithyroidectomy. Pathologic analysis assessed surgical specimens; postoperative complications and resolution of hyperthyroidism were noted. Two hundred patients from 15 to 83 years old were included. One hundred and eighty-eight underwent primary surgery and 12 were re-operated for recurrent goiter (6 with subtotal thyroidectomy for multinodular goiter 25 years previously; 6 with hemithyroidectomy for solitary nodule 15 years previously). Eighty-two patients suffered from toxic multinodular goiter, 78 from Graves' disease, 35 from solitary toxic nodules and 5 from amiodarone-associated thyrotoxicosis. Fourteen papillary carcinomas (including 11 papillary microcarcinomas) and 34 healthy parathyroid glands (17%) were identified in the pathological specimens. Postoperative complications comprised 4% permanent recurrent laryngeal nerve palsy (1 year follow-up), 9% hematoma requiring surgical revision, and 3% definitive hypocalcemia. Normalization of thyroid hormone levels was observed in 198 patients. Two recurrences occurred due to incomplete resection (1 case of Graves' disease and 1 intrathoracic toxic goiter that occurred respectively 18 and 5 months after resection). Postoperative complications were more frequent in multinodular goiter (23%) than in Graves' disease (13%) (ns: P>0.05). Surgical management of hyperthyroidism enables good endocrinal control if surgery is complete. Patients need to be fully informed of all possible postoperative complications

  5. Estimation of stress distribution in ferromagnetic tensile specimens using low cost eddy current stress measurement system and BP neural network.

    Directory of Open Access Journals (Sweden)

    Jianwei Li

    Full Text Available Estimation of the stress distribution in ferromagnetic components is very important for evaluating the working status of mechanical equipment and implementing preventive maintenance. Eddy current testing technology is a promising method in this field because of its advantages of safety, no need of coupling agent, etc. In order to reduce the cost of eddy current stress measurement system, and obtain the stress distribution in ferromagnetic materials without scanning, a low cost eddy current stress measurement system based on Archimedes spiral planar coil was established, and a method based on BP neural network to obtain the stress distribution using the stress of several discrete test points was proposed. To verify the performance of the developed test system and the validity of the proposed method, experiment was implemented using structural steel (Q235 specimens. Standard curves of sensors at each test point were achieved, the calibrated data were used to establish the BP neural network model for approximating the stress variation on the specimen surface, and the stress distribution curve of the specimen was obtained by interpolating with the established model. The results show that there is a good linear relationship between the change of signal modulus and the stress in most elastic range of the specimen, and the established system can detect the change in stress with a theoretical average sensitivity of -0.4228 mV/MPa. The obtained stress distribution curve is well consonant with the theoretical analysis result. At last, possible causes and improving methods of problems appeared in the results were discussed. This research has important significance for reducing the cost of eddy current stress measurement system, and advancing the engineering application of eddy current stress testing.

  6. Functional outcome measures in a surgical model of hip osteoarthritis in dogs.

    Science.gov (United States)

    Little, Dianne; Johnson, Stephen; Hash, Jonathan; Olson, Steven A; Estes, Bradley T; Moutos, Franklin T; Lascelles, B Duncan X; Guilak, Farshid

    2016-12-01

    The hip is one of the most common sites of osteoarthritis in the body, second only to the knee in prevalence. However, current animal models of hip osteoarthritis have not been assessed using many of the functional outcome measures used in orthopaedics, a characteristic that could increase their utility in the evaluation of therapeutic interventions. The canine hip shares similarities with the human hip, and functional outcome measures are well documented in veterinary medicine, providing a baseline for pre-clinical evaluation of therapeutic strategies for the treatment of hip osteoarthritis. The purpose of this study was to evaluate a surgical model of hip osteoarthritis in a large laboratory animal model and to evaluate functional and end-point outcome measures. Seven dogs were subjected to partial surgical debridement of cartilage from one femoral head. Pre- and postoperative pain and functional scores, gait analysis, radiographs, accelerometry, goniometry and limb circumference were evaluated through a 20-week recovery period, followed by histological evaluation of cartilage and synovium. Animals developed histological and radiographic evidence of osteoarthritis, which was correlated with measurable functional impairment. For example, Mankin scores in operated limbs were positively correlated to radiographic scores but negatively correlated to range of motion, limb circumference and 20-week peak vertical force. This study demonstrates that multiple relevant functional outcome measures can be used successfully in a large laboratory animal model of hip osteoarthritis. These measures could be used to evaluate relative efficacy of therapeutic interventions relevant to human clinical care.

  7. Reactor Materials Program electrochemical potential measurements by ORNL with unirradiated and irradiated stainless steel specimens

    Energy Technology Data Exchange (ETDEWEB)

    Baumann, E.W.; Caskey, G.R. Jr.

    1993-07-01

    Effect of irradiation of stainless steel on electrochemical potential (ECP) was investigated by measurements in dilute HNO{sub 3} and H{sub 2}O{sub 2} solutions, conditions simulating reactor moderator. The electrodes were made from unirradiated/irradiated, unsensitized/sensitized specimens from R-reactor piping. Results were inconclusive because of budgetary restrictions. The dose rate may have been too small to produce a significant radiolytic effect. Neither the earlier CERT corrosion susceptibility tests nor the present ECP measurements showed a pronounced effect of irradiation on susceptibility of the stainless steel to IGSCC; this is confirmed by the absence in the stainless steel of the SRS reactor tanks (except for the C Reactor tank knuckle area).

  8. Reactor Materials Program electrochemical potential measurements by ORNL with unirradiated and irradiated stainless steel specimens

    International Nuclear Information System (INIS)

    Baumann, E.W.; Caskey, G.R. Jr.

    1993-07-01

    Effect of irradiation of stainless steel on electrochemical potential (ECP) was investigated by measurements in dilute HNO 3 and H 2 O 2 solutions, conditions simulating reactor moderator. The electrodes were made from unirradiated/irradiated, unsensitized/sensitized specimens from R-reactor piping. Results were inconclusive because of budgetary restrictions. The dose rate may have been too small to produce a significant radiolytic effect. Neither the earlier CERT corrosion susceptibility tests nor the present ECP measurements showed a pronounced effect of irradiation on susceptibility of the stainless steel to IGSCC; this is confirmed by the absence in the stainless steel of the SRS reactor tanks (except for the C Reactor tank knuckle area)

  9. Simultaneous specimen current and time-dependent cathodoluminescence measurements on gallium nitride

    Energy Technology Data Exchange (ETDEWEB)

    Campo, E. M., E-mail: e.campo@bangor.ac.uk; Hopkins, L. [School of Electronic Engineering, Bangor University, Gwynedd LL57 1UT (United Kingdom); Pophristic, M. [Department of Chemistry and Biochemistry, University of the Science, Philadelphia, Pennsylvania 19104 (United States); Ferguson, I. T. [Department of Electrical and Computer Engineering, Missouri University of Science and Technology, Rolla, Missouri 65409 (United States)

    2016-06-28

    Time-dependent cathodoluminescence (CL) and specimen current (SC) are monitored to evaluate trapping behavior and evolution of charge storage. Examination of CL and SC suggests that the near band edge emission in GaN is reduced primarily by the activation of traps upon irradiation, and Gallium vacancies are prime candidates. At the steady state, measurement of the stored charge by empiric-analytical methods suggests that all available traps within the interaction volume have been filled, and that additional charge is being stored interstitially, necessarily beyond the interaction volume. Once established, the space charge region is responsible for the steady state CL emission and, prior to build up, it is responsible for the generation of diffusion currents. Since the non-recombination effects resulting from diffusion currents that develop early on are analogous to those leading to device failure upon aging, this study is fundamental toward a holistic insight into optical properties in GaN.

  10. Influence of specimen type and reinforcement on measured tension-tension fatigue life of unidirectional GFRP laminates

    DEFF Research Database (Denmark)

    Korkiakoski, Samuli; Brøndsted, Povl; Sarlin, Essi

    2016-01-01

    It is well known that standardised tension-tension fatigue test specimens of unidirectional (UD) glass-fibre-reinforced plastics (GFRP) laminates tend to fail at end tabs. The true fatigue life is then underestimated. The first objective of this study was to find for UD GFRP laminates a test...... specimen that fails in the gauge section. The second objective was to compare fatigue performance of two laminates, one having a newly developed UD powder-bound fabric as a reinforcement and the other having a quasi-UD stitched non-crimp fabric as a reinforcement. In the first phase, a rectangular specimen...... in accordance with the ISO 527-5 standard and two slightly different dog-bone shaped specimens were evaluated by means of finite element modelling. Subsequent comparative fatigue tests were performed for the laminates with the three specimen types. The results showed that the test specimen type has...

  11. Output control of da Vinci surgical system's surgical graspers.

    Science.gov (United States)

    Johnson, Paul J; Schmidt, David E; Duvvuri, Umamaheswar

    2014-01-01

    The number of robot-assisted surgeries performed with the da Vinci surgical system has increased significantly over the past decade. The articulating movements of the robotic surgical grasper are controlled by grip controls at the master console. The user interface has been implicated as one contributing factor in surgical grasping errors. The goal of our study was to characterize and evaluate the user interface of the da Vinci surgical system in controlling surgical graspers. An angular manipulator with force sensors was used to increment the grip control angle as grasper output angles were measured. Input force at the grip control was simultaneously measured throughout the range of motion. Pressure film was used to assess the maximum grasping force achievable with the endoscopic grasping tool. The da Vinci robot's grip control angular input has a nonproportional relationship with the grasper instrument output. The grip control mechanism presents an intrinsic resistant force to the surgeon's fingertips and provides no haptic feedback. The da Vinci Maryland graspers are capable of applying up to 5.1 MPa of local pressure. The angular and force input at the grip control of the da Vinci robot's surgical graspers is nonproportional to the grasper instrument's output. Understanding the true relationship of the grip control input to grasper instrument output may help surgeons understand how to better control the surgical graspers and promote fewer grasping errors. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Surgical management of gynecomastia--a 10-year analysis.

    Science.gov (United States)

    Handschin, A E; Bietry, D; Hüsler, R; Banic, A; Constantinescu, M

    2008-01-01

    Gynecomastia is defined as the benign enlargement of the male breast. Most studies on surgical treatment of gynecomastia show only small series and lack histopathology results. The aim of this study was to analyze the surgical approach in the treatment of gynecomastia and the related outcome over a 10-year period. All patients undergoing surgical gynecomastia corrections in our department between 1996 and 2006 were included for retrospective evaluation. The data were analyzed for etiology, stage of gynecomastia, surgical technique, complications, risk factors, and histological results. A total of 100 patients with 160 operations were included. Techniques included subcutaneous mastectomy alone or with additional hand-assisted liposuction, isolated liposuction, and formal breast reduction. Atypical histological findings were found in 3% of the patients (spindle-cell hemangioendothelioma, papilloma). The surgical revision rate among all patients was 7%. Body mass index and a weight of the resected specimen higher than 40 g were identified as significant risk factors for complications (p gynecomastia requires an individualized approach. Caution must be taken in performing large resections, which are associated with increased complication rates. Histological tissue analysis should be routinely performed in all true gynecomastia corrections, because histological results may reveal atypical cellular pathology.

  13. Antibiotic Susceptibility Pattern of Aerobic and Anaerobic Bacteria Isolated From Surgical Site Infection of Hospitalized Patients.

    Science.gov (United States)

    Akhi, Mohammad Taghi; Ghotaslou, Reza; Beheshtirouy, Samad; Asgharzadeh, Mohammad; Pirzadeh, Tahereh; Asghari, Babak; Alizadeh, Naser; Toloue Ostadgavahi, Ali; Sorayaei Somesaraei, Vida; Memar, Mohammad Yousef

    2015-07-01

    Surgical Site Infections (SSIs) are infections of incision or deep tissue at operation sites. These infections prolong hospitalization, delay wound healing, and increase the overall cost and morbidity. This study aimed to investigate anaerobic and aerobic bacteria prevalence in surgical site infections and determinate antibiotic susceptibility pattern in these isolates. One hundred SSIs specimens were obtained by needle aspiration from purulent material in depth of infected site. These specimens were cultured and incubated in both aerobic and anaerobic condition. For detection of antibiotic susceptibility pattern in aerobic and anaerobic bacteria, we used disk diffusion, agar dilution, and E-test methods. A total of 194 bacterial strains were isolated from 100 samples of surgical sites. Predominant aerobic and facultative anaerobic bacteria isolated from these specimens were the members of Enterobacteriaceae family (66, 34.03%) followed by Pseudomonas aeruginosa (26, 13.4%), Staphylococcus aureus (24, 12.37%), Acinetobacter spp. (18, 9.28%), Enterococcus spp. (16, 8.24%), coagulase negative Staphylococcus spp. (14, 7.22%) and nonhemolytic streptococci (2, 1.03%). Bacteroides fragilis (26, 13.4%), and Clostridium perfringens (2, 1.03%) were isolated as anaerobic bacteria. The most resistant bacteria among anaerobic isolates were B. fragilis. All Gram-positive isolates were susceptible to vancomycin and linezolid while most of Enterobacteriaceae showed sensitivity to imipenem. Most SSIs specimens were polymicrobial and predominant anaerobic isolate was B. fragilis. Isolated aerobic and anaerobic strains showed high level of resistance to antibiotics.

  14. Response of a PGNAA setup for pozzolan-based cement concrete specimens

    International Nuclear Information System (INIS)

    Naqvi, A.A.; Garwan, M.A.; Maslehuddin, M.; Nagadi, M.M.; Al-Amoudi, O.S.B.; Raashid, M.

    2010-01-01

    Pozzolanic materials are added to Portland cement concrete to increase its durability, particularly corrosion-resistance. In this study the elemental composition of a pozzolanic cement concrete was measured non-destructively utilizing an accelerator-based Prompt Gamma Ray Neutron Activation Analysis (PGNAA) setup. The optimum size of the pozzolanic cement concrete specimen was obtained through Monte Carlo simulations. The simulation results were experimentally verified through the γ-ray yield measurement from the pozzolanic cement concrete specimens as a function of their radii. The concentration of the pozzolanic material in the cement concrete specimens was evaluated by measuring γ-ray yield for calcium and iron from pozzolanic cement concrete specimens containing 5-80 wt% pozzolan. A good agreement was noted between the experimental values and the Monte Carlo simulation results, indicating an excellent response of the KFUPM accelerator-based PGNAA setup for pozzolan based concrete.

  15. Response of a PGNAA setup for pozzolan-based cement concrete specimens

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)], E-mail: aanaqvi@kfupm.edu.sa; Garwan, M.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Maslehuddin, M. [Center for Engineering Research, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Raashid, M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2010-04-15

    Pozzolanic materials are added to Portland cement concrete to increase its durability, particularly corrosion-resistance. In this study the elemental composition of a pozzolanic cement concrete was measured non-destructively utilizing an accelerator-based Prompt Gamma Ray Neutron Activation Analysis (PGNAA) setup. The optimum size of the pozzolanic cement concrete specimen was obtained through Monte Carlo simulations. The simulation results were experimentally verified through the {gamma}-ray yield measurement from the pozzolanic cement concrete specimens as a function of their radii. The concentration of the pozzolanic material in the cement concrete specimens was evaluated by measuring {gamma}-ray yield for calcium and iron from pozzolanic cement concrete specimens containing 5-80 wt% pozzolan. A good agreement was noted between the experimental values and the Monte Carlo simulation results, indicating an excellent response of the KFUPM accelerator-based PGNAA setup for pozzolan based concrete.

  16. Scanning transmission ion micro-tomography (STIM-T) of biological specimens

    International Nuclear Information System (INIS)

    Schwertner, Michael; Sakellariou, Arthur; Reinert, Tilo; Butz, Tilman

    2006-01-01

    Computed tomography (CT) was applied to sets of Scanning Transmission Ion Microscopy (STIM) projections recorded at the LIPSION ion beam laboratory (Leipzig) in order to visualize the 3D-mass distribution in several specimens. Examples for a test structure (copper grid) and for biological specimens (cartilage cells, cygospore) are shown. Scanning Transmission Micro-Tomography (STIM-T) at a resolution of 260 nm was demonstrated for the first time. Sub-micron features of the Cu-grid specimen were verified by scanning electron microscopy. The ion energy loss measured during a STIM-T experiment is related to the mass density of the specimen. Typically, biological specimens can be analysed without staining. Only shock freezing and freeze-drying is required to preserve the ultra-structure of the specimen. The radiation damage to the specimen during the experiment can be neglected. This is an advantage compared to other techniques like X-ray micro-tomography. At present, the spatial resolution is limited by beam position fluctuations and specimen vibrations

  17. Friction Compensation in the Upsetting of Cylindrical Test Specimens

    DEFF Research Database (Denmark)

    Christiansen, Peter; Martins, P. A. F.; Bay, Niels Oluf

    2016-01-01

    This manuscript presents a combined numerical andexperimental methodology for determining the stress-straincurve of metallic materials from the measurements of forceand displacement obtained in the axial compression of cylindrical test specimens with friction between the specimens and the platens....... The methodology is based on minimizing the errorbetween the average surface pressure obtained from the experimental measurements of the force and displacement and thatobtained from the slab method of analysis of metal plasticity.Three different friction models based on Coulomb friction, the constant friction...... model or combined friction models are utilized .Experimental results obtained from cylindrical and Rastegaev test specimens with different lubricants combined with the experimental determination of friction by means of ring compression tests allows compensating the effect of friction...

  18. Measuring Error Identification and Recovery Skills in Surgical Residents.

    Science.gov (United States)

    Sternbach, Joel M; Wang, Kevin; El Khoury, Rym; Teitelbaum, Ezra N; Meyerson, Shari L

    2017-02-01

    Although error identification and recovery skills are essential for the safe practice of surgery, they have not traditionally been taught or evaluated in residency training. This study validates a method for assessing error identification and recovery skills in surgical residents using a thoracoscopic lobectomy simulator. We developed a 5-station, simulator-based examination containing the most commonly encountered cognitive and technical errors occurring during division of the superior pulmonary vein for left upper lobectomy. Successful completion of each station requires identification and correction of these errors. Examinations were video recorded and scored in a blinded fashion using an examination-specific rating instrument evaluating task performance as well as error identification and recovery skills. Evidence of validity was collected in the categories of content, response process, internal structure, and relationship to other variables. Fifteen general surgical residents (9 interns and 6 third-year residents) completed the examination. Interrater reliability was high, with an intraclass correlation coefficient of 0.78 between 4 trained raters. Station scores ranged from 64% to 84% correct. All stations adequately discriminated between high- and low-performing residents, with discrimination ranging from 0.35 to 0.65. The overall examination score was significantly higher for intermediate residents than for interns (mean, 74 versus 64 of 90 possible; p = 0.03). The described simulator-based examination with embedded errors and its accompanying assessment tool can be used to measure error identification and recovery skills in surgical residents. This examination provides a valid method for comparing teaching strategies designed to improve error recognition and recovery to enhance patient safety. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Instrumented impact testing machine with reduced specimen oscillation effects

    International Nuclear Information System (INIS)

    Rintamaa, R.; Rahka, K.; Wallin, K.

    1984-07-01

    Owing to small and inexpensive specimens the Charpy impact test is widely used in quality control and alloy development. Limitations in power reactor survellance capsules it is also widely used for safety analysis purposes. Instrumenting the tup and computerizing data acquisition, makes dynamic fracture mechanics data measurement possible and convenient. However, the dynamic effects (inertia forces, specimen oscillations) in the impact test cause inaccuracies in the recorded load-time diagram and hence diminish the reliability of the calculated dynamic fracture mechanics parameters. To decrease inaccuracies a new pendulum type of instrumented impact test apparatus has been developed and constructed in the Metals Laboratory of the Technical Research Centre of Finland. This tester is based on a new principle involving inverted test geometry. The purpose of the geometry inversion is to reduce inertia load and specimen oscillation effects. Further, the new impact tester has some other novel features: e.g. the available initia impact energy is about double compared to the conventional standard (300 J) impact tester allowing the use of larger (10 x 20 x 110 mm) bend specimens than normal Charpy specimens. Also, the rotation asix in the three point bending is nearly stationary making COD-measurements possible. An experimental test series is described in which the inertia effects and specimen oscillations are compared in the conventional and new impact tester utilizing Charpy V-notch specimens. Comparison of the two test geometries is also made with the aid of an analytical model using finite element method (FEM) analysis. (author)

  20. Clinical evaluation of preoperative arterial infusion chemotherapy and surgical operation for colorectal carcinoma

    International Nuclear Information System (INIS)

    Yuan Jianhua; Zhao Zhongsheng; Deng Gaoli; Hu Tingyang; Yu Wenqiang; Chen Fanghong; Luo Zuyan; Ru Guoqing; Dong Quanjin; Tu Shiliang

    2003-01-01

    Objective: To investigate the clinical values of preoperative arterial infusion chemotherapy and surgical operation for colorectal carcinoma. Methods: 66 patients with colorectal carcinoma were subjected to percutaneous femoral artery catheterization by Seldinger's technique with infusion of anti-cancer drugs. The resection was performed 5-30 days after the arterial infusion (mean 12 days). In 50 surgical specimens of the 66 cases, histological findings were evaluated including the density and distribution of the apoptosis cells under the observation by DNA nick end labelling technique. Of which 22 specimens before arterial infusion chemotherapy (got from biopsy of preoperation) and 25 normal mucosa (got from normal surgical specimens) were used as controls. Results: The total histological response rate was 100% with grade I in 20 cases, grade II in 21 cases, grade III in 9 cases. The densities of the apoptosis cells were 31.47 ± 5.58 before arterial infusion chemotherapy, 76.69 ± 17.12 after arterial infusion chemotherapy and 8.01 ± 3.39 in normal mucosa. The density of the apoptosis cells after arterial infusion chemotherapy was significantly higher than that before arterial infusion chemotherapy (P 2 =4.696, P>0.30). There were no significant differences in the apoptosis of adenocarcinoma during different pathological stages (F=0.001376, P>0.05). Conclusions: Peroperative transcatheter arterial infusion chemotherapy resulting in apoptosis of adenocarcinoma, can raise the radical operation rate, and prolong survival rate for colorectal carcinoma patients

  1. Correlation of clinical data with fallopian tube specimen immune cells and tissue culture capacity.

    Science.gov (United States)

    Ramraj, Satish Kumar; Smith, Katie M; Janakiram, Naveena B; Toal, Coralee; Raman, Ankita; Benbrook, Doris Mangiaracina

    2018-06-01

    Human fallopian tube fimbria secretory epithelial cells (hFTSECs) are considered an origin of ovarian cancer and methods for their culture from fallopian tube specimens have been reported. Our objective was to determine whether characteristics of the donors or surgeries were associated with the capacities of fimbria specimens to generate hFTSEC cultures or their immune profiles. There were no surgical complications attributable to fallopian tube removal. Attempts to establish primary hFTSEC cultures were successful in 37 of 55 specimens (67%). Success rates did not differ significantly between specimens grouped by patient or surgery characteristics. Established cultures could be revived after cryopreservation and none became contaminated with microorganisms. Two cultures evaluated for long term growth senesced between passages 10 and 15. M1 macrophages were the predominant cell type, while all other immune cells were present at much lower percentages. IL-10 and TGF-β exhibited opposing trends with M1 and M2 macrophages. Plasma IL-10 levels exhibited significant positive correlation with patient age. In conclusion, fallopian tube fimbria specimens exhibit a pro-inflammatory phenotype and can be used to provide a source of hFTSECs that can be cultured for a limited time regardless of the donor patient age or race, or the type of surgery performed. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Thermal expansion of epoxy-fiberglass composite specimens

    International Nuclear Information System (INIS)

    McElroy, D.L.; Weaver, F.J.; Bridgman, C.

    1986-01-01

    The thermal expansion behavior of three epoxy-fiberglass composite specimens was measured from 20 to 120 0 C (70 to 250 0 F) using a fused quartz push-rod dilatometer. Billets produced by vacuum impregnating layers of two types of fiberglass cloth with an epoxy resin were core-drilled to produce cylindrical specimens. These were used to study expansion perpendicular and parallel to the fiberglass layers. The dilatometer is held at a preselected temperature until steady-state is indicated by stable length and temperature data. Before testing the composite specimens, a reliability check of the dilatometer was performed using a copper secondary standard. This indicated thermal expansion coefficient (α) values within +-2% of expected values from 20 to 200 0 C

  3. Use of miniaturized compact tension specimens for fracture toughness measurements in the upper shelf regime. Electrabel/Tractebel-SCK-CEN Convention 2004 Task 1.1.4/2

    International Nuclear Information System (INIS)

    Lucon, E.; Scibetta, M.; Chaouadi, R.; Walle, E. van

    2005-04-01

    In the nuclear field, the importance of direct fracture toughness measurements on RPV materials has been nowadays widely recognized, as opposed to Charpy-based estimations. However, sample dimensions have to be kept small in order to optimize the use of available material (often in the form of previously broken Charpy specimens) or, in the case of new irradiations, make effective use of the limited space available inside irradiation facilities. One of the most appealing geometries for fracture toughness measurements is the miniature Compact Tension specimen, MC(T), which has the following dimensions: B = 4.15 mm, W = 8.3 mm, cross section 10 x 10 mm 2 . Four MC(T) specimens can be machined out of a broken half Charpy, and in the case of irradiation ten MC(T) samples occupy approximately the same volume as a full-size Charpy specimen. The MC(T) geometry was already successfully applied and qualified for fracture toughness assessments in the ductile-to-brittle transition regime, using the Master Curve method (ASTM E1921-03). A further, comprehensive investigation is presented in this report, aimed at assessing the applicability of MC(T) specimens to measure fracture toughness in fully ductile (upper shelf) conditions. In this study, 18 1TC(T) and 20 MC(T) specimens have been tested at different temperatures from three RPV steels and one low-alloy C-Mn steel. The results obtained clearly show that MC(T) samples exhibit lower fracture toughness properties, both in terms of initiation of ductile tearing (according to various test standards) and resistance to ductile crack propagation (J-R curve). The reduction of tearing resistance might be attributed to work hardening prevailing over loss of constraint in the uncracked ligament in a side-grooved specimen, or to the inadequacy of J-integral to represent ductile crack extension in very small specimens. Both arguments will have to be verified with further investigations. (author)

  4. Measurements of T1 and T2 over time in formalin-fixed human whole-brain specimens

    International Nuclear Information System (INIS)

    Tovi, M.; Ericsson, A.

    1992-01-01

    T1 and T2 were measured in 5 formalin-fixed human whole-brain specimens as a function of time. Gray matter/white matter contrast reversal was observed around the 4th day and was considered to be due to the greater decrease in T1 in gray than in white matter. A possible explanation for this is that the decomposition of the myelin phospholipid structure by formalin somewhat counteracts the general reductive effect of the fixation procedure on relaxation times. (orig.)

  5. Can virtual reality be used to measure and train surgical skills?

    Science.gov (United States)

    Arnold, Paul; Farrell, Martin J

    2002-04-15

    The quantitative literature on the use of virtual environments to measure and train a variety of surgical skills is critically reviewed. We selected works from the years 1995-2000. Theoretical perspectives, such as those of Saltzman (1979), Bernstein (1967) and Schmidt (1975) and techniques, such as hierarchical task analysis, are presented and contrasted with the largely atheoretical approach of the practitioners of virtual surgery. It is concluded that the quantitative work discussed provides few findings of value to practising surgeons. This may be due in part to the lack of consideration paid to fundamental issues in the learning of motor skills, such as whether motor skills learning is most effective with varying training conditions and the distinction between purely motoric aspects and knowledge of procedures. Possible ways forward for surgical training are outlined. It is suggested that the theoretical perspectives and techniques available in the area of motor behaviour should be incorporated into future experimental studies of surgery in virtual environments.

  6. Thick Concrete Specimen Construction, Testing, and Preliminary Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hoegh, Kyle [Univ. of Minnesota, Minneapolis, MN (United States); Khazanovich, Lev [Univ. of Minnesota, Minneapolis, MN (United States)

    2015-03-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the various nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations. A preliminary report detailed some of the challenges associated with thick reinforced concrete sections and prioritized conceptual designs of specimens that could be fabricated to represent NPP concrete structures for using in NDE evaluation comparisons. This led to the construction of the concrete specimen presented in this report, which has sufficient reinforcement density and cross-sectional size to represent an NPP containment wall. Details on how a suitably thick concrete specimen was constructed are presented, including the construction materials, final nominal design schematic, as well as formwork and rigging required to safely meet the desired dimensions of the concrete structure. The report also details the type and methods of forming the concrete specimen as well as information on how the rebar and simulated defects were embedded. Details on how the resulting specimen was transported, safely anchored, and marked to allow access for systematic comparative NDE testing of defects in a representative NPP containment wall concrete specimen are also given. Data collection using the MIRA Ultrasonic NDE equipment and

  7. Objective Measurement of Clinical Competency in Surgical Education Using Electrodermal Activity.

    Science.gov (United States)

    Quick, Jacob A; Bukoski, Alex D; Doty, Jennifer; Bennett, Bethany J; Crane, Megan; Barnes, Stephen L

    Within the realm of surgical education, there is a need for objective means to determine surgical competence and resident readiness to operate independently. We propose a novel, objective method of assessing resident confidence and clinical competence based on measurement of electrodermal activity (EDA) during live surgical procedures. We hypothesized that with progressive training, EDA responses to the stress of performing surgery would exhibit decline, elucidating an objective correlate of clinical competence. EDA was measured using galvanic skin response sensors worn by residents performing laparoscopic cholecystectomy on sequential live human patients over an 8-month period. Baseline, phasic (peak) and tonic EDA responses were measured as a fractional change from baseline. University of Missouri, Columbia, Missouri, an academic tertiary care facility. Fourteen categorical general surgery residents and 5 faculty surgeons were voluntarily enrolled and participated through completion. Tonic fractional change (FC TONIC ) was highest in PGY3 residents compared with postgraduate year (PGY) 1 and 2 residents (7.199 vs. 2.100, p = 0.004, 95% CI: 8.58-1.61 and PGY4 and 5 residents (7.199 vs. 2.079, p = 0.002, 95% CI: 8.38-0.29). Phasic fractional change in EDA (FC PHASIC ) exhibited a progressive decline across resident training levels, with PGY1 and 2 residents having the highest response, and faculty displaying the lowest FC PHASIC responses. Statistical differences were seen between FC PHASIC faculty and PGY4 and 5 (3.596 vs. 6.180, p = 0.004, 95% CI: 0.80-4.36), PGY4 and 5, and PGY3 (6.180 vs. 15.998, p = 0.003, 95% CI: 3.33-16.3), as well as among all residents and faculty (13.057 vs. 3.596, p = 0.004, 95% CI: 15.8-3.1). Phasic EDA changes decrease with increasing clinical competence. For those participants with the lowest and highest levels of competence, tonic EDA changes are minimal. Tonic EDA changes follow an inverse-U shape with differing levels of clinical

  8. The effect of preoperative therapy against advanced oral cancer. The pattern of residual cancer nests assessed with semiserial whole surgical specimens

    International Nuclear Information System (INIS)

    Kawano, Kenji

    2008-01-01

    Histological change of advanced oral cancers following concurrent chemoradiotherapy was examined with semiserial whole surgical specimens. Subjects included six tongue squamous cell carcinomas (SCCs), two oral floor SCCs and three lower gingival SCCs, and all the tumors were preoperatively treated by the combination of radiotherapy and superselective intraarterial infusion of carboplatin (CBDCA) or oral administration of TS-1. Clinical effect was assessed as complete response (CR) in three cases, partial response (PR) in five, minor response (MR) in two and no change (NC) in two. The distribution of residual cancer nests was categorized as the superficially-located and deeply-located patterns. It was noteworthy that the pattern of residual cancer nests and the histological effect were different between sections even in the same tumors. Furthermore, a few viable cancer nests were observed exclusively in the advancing edge in tumors assessed as Grade 2b (Oboshi-Shimosata classification), where most of the cancer nests were degenerative or necrotic. This finding suggests that the extent of resection could not be reduced even in tumors that responded well to preoperative therapy. In the present cases, the histological effect of chemoradiotherapy was evaluated as Grade 4a in two cases, Grade 2b in four, Grade 2a in five and Grade 1 in one. Tumors of the PR showed a wide variation of histological evaluation from Grade 1 to Grade 4a, resulting in a discrepancy between the clinical and histological evaluations. (author)

  9. Residual stress state in pipe cut ring specimens for fracture toughness testing

    Energy Technology Data Exchange (ETDEWEB)

    Damjanovic, Darko [J.J. Strossmayer Univ. of Osijek, Slavonski Brod (Croatia). Mechanical Engineering Faculty; Kozak, Drazan [Zagreb Univ. (Croatia). Dept. for Mechanical Design; Marsoner, Stefan [Materials Center, Leoben (Austria).; Gubeljak, Nenad [Maribor Univ. (Slovenia). Chair of Mechanics

    2017-07-01

    Thin-walled pipes are not suitable for measuring fracture toughness parameters of vital importance because longitudinal crack failure is the most common failure mode in pipes. This is due to the impossibility to manufacture standard specimens for measuring fracture toughness, such as SENB or CT specimens, from the thin wall of the pipe. Previous works noticed this problem, but until now, a good and convenient solution has not been found or developed. To overcome this problem, very good alternative solution was proposed, the so-called pipe ring notched bend specimen (PRNB) [1-5]. Until now, only the idealized geometry PRNB specimen is analyzed, i. e., a specimen which is not cut out from an actual pipe but produced from steel plate. Based on that, residual stresses are neglected along with the imperfections in geometry (elliptical and eccentricity). The aim of this research is to estimate the residual stress state(s) in real pipes used in the boiler industry produced by hot rolling technique. These types of pipes are delivered only in normalized condition, but not stress relieved. Therefore, there are residual stresses present due to the manufacturing technique, but also due to uneven cooling after the production process. Within this paper, residual stresses are estimated by three methods: the incremental hole drilling method (IHMD), X-ray diffraction (XRD) and the splitting method (SM). Knowing the residual stress state in the ring specimen, it is possible to assess their impact on fracture toughness measured on the corresponding PRNB specimen(s).

  10. Residual stress state in pipe cut ring specimens for fracture toughness testing

    International Nuclear Information System (INIS)

    Damjanovic, Darko; Kozak, Drazan; Marsoner, Stefan; Gubeljak, Nenad

    2017-01-01

    Thin-walled pipes are not suitable for measuring fracture toughness parameters of vital importance because longitudinal crack failure is the most common failure mode in pipes. This is due to the impossibility to manufacture standard specimens for measuring fracture toughness, such as SENB or CT specimens, from the thin wall of the pipe. Previous works noticed this problem, but until now, a good and convenient solution has not been found or developed. To overcome this problem, very good alternative solution was proposed, the so-called pipe ring notched bend specimen (PRNB) [1-5]. Until now, only the idealized geometry PRNB specimen is analyzed, i. e., a specimen which is not cut out from an actual pipe but produced from steel plate. Based on that, residual stresses are neglected along with the imperfections in geometry (elliptical and eccentricity). The aim of this research is to estimate the residual stress state(s) in real pipes used in the boiler industry produced by hot rolling technique. These types of pipes are delivered only in normalized condition, but not stress relieved. Therefore, there are residual stresses present due to the manufacturing technique, but also due to uneven cooling after the production process. Within this paper, residual stresses are estimated by three methods: the incremental hole drilling method (IHMD), X-ray diffraction (XRD) and the splitting method (SM). Knowing the residual stress state in the ring specimen, it is possible to assess their impact on fracture toughness measured on the corresponding PRNB specimen(s).

  11. 16 CFR Figure 3 to Part 1610 - Specimen Holder Supported in Specimen Rack

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Specimen Holder Supported in Specimen Rack 3 Figure 3 to Part 1610 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT... Holder Supported in Specimen Rack ER25MR08.002 ...

  12. Sequencing historical specimens: successful preparation of small specimens with low amounts of degraded DNA.

    Science.gov (United States)

    Sproul, John S; Maddison, David R

    2017-11-01

    Despite advances that allow DNA sequencing of old museum specimens, sequencing small-bodied, historical specimens can be challenging and unreliable as many contain only small amounts of fragmented DNA. Dependable methods to sequence such specimens are especially critical if the specimens are unique. We attempt to sequence small-bodied (3-6 mm) historical specimens (including nomenclatural types) of beetles that have been housed, dried, in museums for 58-159 years, and for which few or no suitable replacement specimens exist. To better understand ideal approaches of sample preparation and produce preparation guidelines, we compared different library preparation protocols using low amounts of input DNA (1-10 ng). We also explored low-cost optimizations designed to improve library preparation efficiency and sequencing success of historical specimens with minimal DNA, such as enzymatic repair of DNA. We report successful sample preparation and sequencing for all historical specimens despite our low-input DNA approach. We provide a list of guidelines related to DNA repair, bead handling, reducing adapter dimers and library amplification. We present these guidelines to facilitate more economical use of valuable DNA and enable more consistent results in projects that aim to sequence challenging, irreplaceable historical specimens. © 2017 John Wiley & Sons Ltd.

  13. In search of the rainbow: Colored inks in surgical pathology

    Directory of Open Access Journals (Sweden)

    Chandralekha Tampi

    2012-01-01

    Full Text Available Introduction: Although surgical pathologists are aware of the multiple advantages that coloured inks contribute to surgical pathology practice, these coloured inks are not available in India and importing them is not a viable proposition. A systematic search for locally available coloring agents was done, and resulted in identifying specific shades within a popular set of children′s hobby colors of a particular brand. They retain their bright distinct colors on paraffin blocks and sections. These paints are available all over India, and are cheap, safe, and easy to use. Coloring gross specimen excision margins with different colors, adds precision to margin examination. It allows three-dimensional microscopic reconstruction of the tumor vis-a-vis its various neighboring anatomic structures. It allows postoperative comparison of tissue planes predicted by preoperative imaging. It maintains orientation of grossed and dissected specimens, enabling the pathologist to re-visit the grossed specimen, if required, and confidently allows further sampling if necessary. Aim: A systematic search for indigenous coloring agents was carried out, which included the dyes used in the histopathology laboratory, gelatin, commercially available paints, including acrylic paints and inks. Results: The study identified specific shades within a brand of acrylic colors that are easily available and simple to use, with good results on microscopic examination. Conclusion: Colored inks lend precision to margin examination. A set of easily procurable colors are available in our country, which are easy to use, with distinct bright colors, safe, and reliable.

  14. Laparoscopic sleeve gastrectomy for morbid obesity with natural orifice specimen extraction (NOSE).

    Science.gov (United States)

    Gunkova, P; Gunka, I; Zonca, P; Dostalik, J; Ihnat, P

    2015-01-01

    An experience with laparoscopic sleeve gastrectomy using the natural orifice specimen extraction (NOSE) technique. Bariatric surgery is nowadays the only long term effective obesity treatment method. Twenty one consecutive patients underwent laparoscopic sleeve gastrectomy with the use of natural orifice specimen extraction (NOSE) in the Surgical Clinic of Faculty Hospital Ostrava between May 2012 and August 2012. Inclusion criteria were the body mass index (BMI) higher than 35 kg/m2 or higher than 32 kg/m2 accompanied with relevant comorbidities. Among 21 patients in this series, there were three men (14.3%) and 18 women (85.7%). Their mean age was 40.9±10.2 years. Their mean preoperative BMI was 40.4±4.6 kg/m2. No patient had previous bariatric surgery, one patient had laparoscopic fundoplication. All operations were completed laparoscopically with no conversions to an open procedure. In two cases, laparoscopic cholecystectomy was performed and the gallbladder was extracted along with the gastric specimen by transgastric approach. Laparoscopic sleeve gastrectomy is a safe and effective bariatric procedure with low morbidity and mortality. Based on our initial experiences it could be an indication for NOSE with transgastric approach. Obese patients would benefit from this approach due to the elimination of wound complications (Tab. 2, Fig. 3, Ref. 22).

  15. Analysis of the learning curve for pre-cut corneal specimens in preparation for lamellar transplantation: a prospective, single-centre, consecutive case series prepared at the Lions New South Wales Eye Bank.

    Science.gov (United States)

    Martin, Aifric Isabel; Devasahayam, Rajnesh; Hodge, Christopher; Cooper, Simon; Sutton, Gerard L

    2017-09-01

    This study is the first paper to establish a learning curve by a single technician. Preparation of pre-cut corneal endothelial grafts commenced at Lions New South Wales Eye Bank in December 2014. The primary objective of this study was to review the safety and reliability of the preparation method during the first year of production. This is a hospital-based, prospective case series. There were 234 consecutive donor corneal lenticules. Donor lenticules were prepared by a single operator using a linear cutting microkeratome. Immediately prior to cutting, central corneal thickness values were recorded. Measurements of the corneal bed were taken immediately following lenticule preparation. Outcomes were separated by blade sizes, and intended thickness was compared to actual thickness for each setting. Early specimens were compared to later ones to assess for a learning curve within the technique. The main parameter measured is the mean difference from intended lamellar cut thickness. The mean final cut thickness was 122.36 ± 20.35 μm, and the mean difference from intended cut was 30.17 ± 37.45 μm. No significant difference was found between results achieved with early specimens versus those achieved with later specimens (P = 0.425). Thin, reproducible endothelial grafts can routinely be produced by trained technicians at their respective eye banks without significant concerns for an extended learning curve. This service can reduce perioperative surgical complexity, required surgical paraphernalia and theatre times. The consistent preparation of single-pass, ultrathin pre-cut corneas may have additional advantages for surgeons seeking to introduce lamellar techniques. © 2017 Royal Australian and New Zealand College of Ophthalmologists.

  16. Surface orientation effects on bending properties of surgical mesh are independent of tensile properties.

    Science.gov (United States)

    Simon, David D; Andrews, Sharon M; Robinson-Zeigler, Rebecca; Valdes, Thelma; Woods, Terry O

    2018-02-01

    Current mechanical testing of surgical mesh focuses primarily on tensile properties even though implanted devices are not subjected to pure tensile loads. Our objective was to determine the flexural (bending) properties of surgical mesh and determine if they correlate with mesh tensile properties. The flexural rigidity values of 11 different surgical mesh designs were determined along three textile directions (machine, cross-machine, and 45° to machine; n = 5 for each) using ASTM D1388-14 while tracking surface orientation. Tensile testing was also performed on the same specimens using ASTM D882-12. Linear regressions were performed to compare mesh flexural rigidity to mesh thickness, areal mass density, filament diameter, ultimate tensile strength, and maximum extension. Of 33 mesh specimen groups, 30 had significant differences in flexural rigidity values when comparing surface orientations (top and bottom). Flexural rigidity and mesh tensile properties also varied with textile direction (machine and cross-machine). There was no strong correlation between the flexural and tensile properties, with mesh thickness having the best overall correlation with flexural rigidity. Currently, surface orientation is not indicated on marketed surgical mesh, and a single mesh may behave differently depending on the direction of loading. The lack of correlation between flexural stiffness and tensile properties indicates the need to examine mesh bending stiffness to provide a more comprehensive understanding of surgical mesh mechanical behaviors. Further investigation is needed to determine if these flexural properties result in the surgical mesh behaving mechanically different depending on implantation direction. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 854-862, 2018. © 2017 Wiley Periodicals, Inc.

  17. Two cases of laparoscopic total colectomy with natural orifice specimen extraction and review of the literature.

    Science.gov (United States)

    Gundogan, Ersin; Aktas, Aydin; Kayaalp, Cuneyt; Gonultas, Fatih; Sumer, Fatih

    2017-09-01

    We present two cases of natural orifice specimen extraction (NOSE) after laparoscopic total colectomy and ileorectal anastomosis (TC-IRA), and we also review all of the previously reported cases. Our aim was to focus on patient selection for NOSE after TC-IRA. The PubMed and Google Scholar databases were scanned. Demographic features, surgical indications, and techniques were analyzed. Basic calculations were used for statistical analysis. A total of 13 cases were detected in addition to our 2 cases. All of the specimens were removed through the natural orifices successfully. No case required a diverting ileostomy. No patients were converted to open surgery or to conventional laparoscopy. Complications were reported in three patients. Transanal extractions were performed in 12 cases (10 colonic inertia, 2 polyposis), and transvaginal extractions were performed in 3 cases (2 malignancy, 1 colonic inertia). Both transanal and transvaginal specimen extractions after laparoscopic TC-IRA can be preferred. However, transanal extraction seems to be feasible in cases of TC for benign disease with a limited mesenteric-omental resection. If the indication is a malignancy requiring a mesenteric-omental resection, a transvaginal route should be preferred for a voluminous specimen.

  18. Cost-effective framework for basic surgical skills training.

    Science.gov (United States)

    Jiang, Deng-Jin; Wen, Chan; Yang, Ai-Jun; Zhu, Zhi-Li; Lei, Yan; Lan, Yang-Jun; Huang, Qing-Yuan; Hou, Xiao-Yu

    2013-06-01

    The importance of basic surgical skills is entirely agreed among surgical educators. However, restricted by ethical issues, finance etc, the basic surgical skills training is increasingly challenged. Increasing cost gives an impetus to the development of cost-effective training models to meet the trainees' acquisition of basic surgical skills. In this situation, a cost-effective training framework was formed in our department and introduced here. Each five students were assigned to a 'training unit'. The training was implemented weekly for 18 weeks. The framework consisted of an early, a transitional, an integrative stage and a surgical skills competition. Corresponding training modules were selected and assembled scientifically at each stage. The modules comprised campus intranet databases, sponge benchtop, nonliving animal tissue, local dissection specimens and simulating reality operations. The training outcomes used direct observation of procedural skills as an assessment tool. The training data of 50 trainees who were randomly selected in each year from 2006 to 2011 year, were retrospectively analysed. An excellent and good rate of the surgical skills is from 82 to 88%, but there is no significant difference among 6 years (P > 0.05). The skills scores of the contestants are markedly higher than those of non-contestants (P < 0.05). The average training cost per trainee is about $21.85-34.08. The present training framework is reliable, feasible, repeatable and cost-effective. The skills competition can promote to improve the surgical skills level of trainees. © 2012 The Authors. ANZ Journal of Surgery © 2012 Royal Australasian College of Surgeons.

  19. Application of subsize specimens in nuclear plant life extension

    International Nuclear Information System (INIS)

    Rosinski, S.T.; Kumar, A.S.; Cannon, N.S.; Hamilton, M.L.

    1993-01-01

    The US Department of Energy is sponsoring a research effort through Sandia National Laboratories and the University of Missouri-Rolla to test a correlation for the upper shelf energy (USE) values obtained from the impact testing of subsize Charpy V-notch specimens to those obtained from the testing of full-size samples. The program involves the impact testing of unirradiated and irradiated full-, half-, and third-size Charpy V-notch specimens. To verify the applicability of the correlation on LWR materials, unirradiated and irradiated full-, half-, and third-size Charpy V-notch specimens of a commercial pressure vessel steel (ASTM A533 Grade B) will be tested. The correlation methodology is based on the partitioning of the USE into crack initiation and crack propagation energies. To accomplish this partition, both precracked and notched-only specimens will be used. Whereas the USE of notched-only specimens is the sum of both crack initiation and crack propagation energies, the USE of precracked specimens reflects only the crack propagation component. The difference in the USE of the two types of specimens represents a measure of the crack initiation energy. Normalizing the values of the crack initiation energy to the fracture volume of the sample produces similar values for the full-, half-, and third-size specimens. In addition, the ratios of the USE and the crack propagation energy are also in agreement for full-, half-, and third-size specimens. These two observations will be used to predict the USE of full-size specimens based on subsize USE data. This paper provides details of the program and presents results obtained from the application of the developed correlation methodology to the impact testing of the unirradiated full-, half-, and third-size A533 Grade B Charpy V-notch specimens

  20. Development of surgical skill with singular neurectomy using human cadaveric temporal bones.

    Science.gov (United States)

    Feigl, Georg; Kos, Izabel; Anderhuber, Friedrich; Guyot, Jean Phillippe; Fasel, Jean

    2008-01-01

    Profound anatomical knowledge and surgical experience are essential for safe otological surgery. The surgeon's learning curve is evaluated in performing Gacek's singular neurectomy on cadaveric specimens. One otological surgeon performed Gacek's approach on 96 halves of human heads embalmed according to Thiel's method, divided into four groups (24 halves per group) and evaluated them concurrent to the evaluation of an anatomist after a first surgical attempt. Successful operations were subdivided into "direct hits" of the osseous canal of the posterior ampullary nerve also known as the singular nerve and "indirect hits" with access to the posterior ampullary recess. Unsuccessful operations showed "no hit" of the nerve without lesion of the membranous labyrinth. "Indirect" or "no hits" were reinvestigated in a second attempt to evaluate possible reclassifications due to a learning process of the surgeon. The order of dissection, the rate of success and the changes of results in correlation with the numbers of dissected specimens were documented. The success rate significantly increased from 54.2% direct hits after the first group to 87.36% in the fourth group after the first attempt. Successful operations were performed in 86.5% after completion of the first attempt and 97.9% after the second attempt. The number of new allocations decreased from 11 cases in the first group of dissected specimens to zero in the fourth group. This paper strengthens the value of cadaveric training for surgeons and the crucial role of dissection of a large number of specimens in improvement of the surgeon's experience and success rate.

  1. Cytology specimens offer an effective alternative to formalin-fixed tissue as demonstrated by novel automated detection for ALK break-apart FISH testing and immunohistochemistry in lung adenocarcinoma.

    Science.gov (United States)

    Rosenblum, Frida; Hutchinson, Lloyd M; Garver, Joann; Woda, Bruce; Cosar, Ediz; Kurian, Elizabeth M

    2014-11-01

    Minimally invasive sampling by cytology or core needle biopsy often provides an initial diagnosis for treatment in patients with lung nodules. From these limited specimens, multiple molecular studies are frequently requested. Current guidelines from the US Food and Drug Administration recommend using formalin-fixed paraffin-embedded tissue sections for the detection of anaplastic lymphoma kinase (ALK) gene rearrangement by fluorescence in situ hybridization (FISH). The authors compared alcohol-fixed and formalin-fixed cytology specimens using a novel automated detection for ALK rearrangements by FISH and immunohistochemistry (IHC). ALK FISH testing was performed on 129 lung adenocarcinomas from 71 cytology cases and 58 biopsy/resection specimens using Papanicolaou staining with integrated cytomorphology. IHC with the ALK D5F3 antibody was performed on cases with residual material (88 of 129 cases). The mean age of the patients was 66 years; there were 62 women and 67 men. ALK gene rearrangement was present in 4% of cytology specimens (3 of 71 specimens) and 7% of surgical specimens (4 of 58 specimens). FISH in 13 cases was technically unsuccessful. Of the 7 FISH-positive cases, only 2 cytology cases (4%) and 2 surgical cases (6%) were found to be positive with the ALK antibody, demonstrating 80% concordance. The one case found to be negative for ALK by IHC demonstrated a variant rearrangement of the ALK 2p23 gene locus by FISH. The results of the current study validate the usefulness of alcohol-fixed and/or formalin-fixed cytology specimens for ALK rearrangement by a novel automated FISH method. IHC using the D5F3 antibody for ALK is specific in this limited cohort. The authors also demonstrated that alcohol-fixed cytology specimens can be used for ALK rearrangement by automated FISH, alone or in conjunction with IHC. © 2014 American Cancer Society.

  2. Measurement of temperature fields in specimens of quartz ceramic during surface ablation

    Science.gov (United States)

    Frolov, G. A.; Pasichnyi, V. V.; Suzdal'Tsev, E. I.; Tsyganenko, V. S.

    1989-08-01

    The authors propose a method of mounting thermocouples and have obtained temperature fields within specimens of pure and doped quartz ceramic. The linearity of the dependenceΔ * = fleft( {sqrt tau } right) for deep isotherms has been proved experimentally.

  3. Measuring the Burden of Surgical Disease Averted by Emergency and Essential Surgical Care in a District Hospital in Papua New Guinea.

    Science.gov (United States)

    Stokes, Matthew A R; Guest, Glenn D; Mamadi, Perista; Seta, Westin; Yaubihi, Noel; Karawiga, Grace; Naidi, Billy; Watters, David A K

    2017-03-01

    Timely access to emergency and essential surgical care (EESC) and anaesthesia in low- and middle-income countries (LMICs) prevents premature death, minimises lifelong disability and reduces their economic impact on families and communities. Papua New Guinea is one of the poorest countries in the Pacific region, and provides much of its surgical care at a district hospital level. We aimed to evaluate the surgical capacity of a district hospital in PNG and estimate the effectiveness of surgical interventions provided. We performed a prospective study to calculate the number of DALYs averted for 465 patients treated with surgical care over a 3-month period (Sep-Nov 2013) in Alotau Hospital, Milne Bay Province, PNG (pop 210,000). Data were also collected on infrastructure, workforce, interventions provided and equipment available using the World Health Organization's Integrated Management of Emergency and Essential Surgical Care Toolkit, a survey to assess EESC and surgical capacity. We also performed a retrospective one-year audit of surgical, obstetric and anaesthetic care to provide context with regards to annual disease burden treated and surgical activity. EESC was provided by 11 Surgeons/Anaesthetists/Obstetricians (SAO) providers, equating to 5.7 per 100,000 population (including 4 nurse anaesthetists). They performed 783/100,000 procedures annually. Over the 3-month prospective study period, 4954 DALYs were averted by 465 surgical interventions, 52 % of which were elective. This equates to 18,330 DALYs averted annually or, approximately 18 % of the published but estimated disease burden in the Province in the 2013 Global Burden of Disease Study. The overall peri-operative mortality rate was 1.29 %, with 0.41 % for elective procedures and 2.25 % for emergencies. Much of the burden of surgical disease in Papua New Guinea presenting to Alotau General Hospital serving Milne Bay Province can be effectively treated by a small team providing emergency and

  4. Final Report: Posttest Analysis of Omega II Optical Specimens

    International Nuclear Information System (INIS)

    Newlander, C D; Fisher, J H

    2007-01-01

    Preliminary posttest analyses have been completed on optical specimens exposed during the Omega II test series conducted on 14 July 2006. The Omega Facility, located at the Laboratory for Laser Energetics (LLE) at the University of Rochester was used to produce X-ray environments through the interaction of intense pulsed laser radiation upon germanium-loaded silica aerogels. The optical specimen testing was supported by GH Systems through experiment design, pre- and post-test analyses, specimen acquisition, and overall technical experience. The test specimens were fabricated and characterized by Surface Optics Corporation (SOC), San Diego, CA and were simple protected gold coatings on silica substrates. Six test specimens were exposed, five filtered with thin beryllium foil filters, and one unfiltered which was exposed directly to the raw environment. The experimental objectives were: (1) demonstrate that tests of optical specimens could be performed at the Omega facility; (2) evaluate the use and survivability of beryllium foil filters as a function of thickness; (3) obtain damage data on optical specimens which ranged from no damage to damage; (4) correlate existing thermal response models with the damage data; (5) evaluate the use of the direct raw environment upon the specimen response and the ability/desirability to conduct sensitive optical specimen tests using the raw environment; and (6) initiate the development of a protocol for performing optical coatings/mirror tests. This report documents the activities performed by GH Systems in evaluating and using the environments provided by LLNL, the PUFFTFT analyses performed using those environments, and the calculated results compared to the observed and measured posttest data

  5. Implementation of surgical quality improvement: auditing tool for surgical site infection prevention practices.

    Science.gov (United States)

    Hechenbleikner, Elizabeth M; Hobson, Deborah B; Bennett, Jennifer L; Wick, Elizabeth C

    2015-01-01

    Surgical site infections are a potentially preventable patient harm. Emerging evidence suggests that the implementation of evidence-based process measures for infection reduction is highly variable. The purpose of this work was to develop an auditing tool to assess compliance with infection-related process measures and establish a system for identifying and addressing defects in measure implementation. This was a retrospective cohort study using electronic medical records. We used the auditing tool to assess compliance with 10 process measures in a sample of colorectal surgery patients with and without postoperative infections at an academic medical center (January 2012 to March 2013). We investigated 59 patients with surgical site infections and 49 patients without surgical site infections. First, overall compliance rates for the 10 process measures were compared between patients with infection vs patients without infection to assess if compliance was lower among patients with surgical site infections. Then, because of the burden of data collection, the tool was used exclusively to evaluate quarterly compliance rates among patients with infection. The results were reviewed, and the key factors contributing to noncompliance were identified and addressed. Ninety percent of process measures had lower compliance rates among patients with infection. Detailed review of infection cases identified many defects that improved following the implementation of system-level changes: correct cefotetan redosing (education of anesthesia personnel), temperature at surgical incision >36.0°C (flags used to identify patients for preoperative warming), and the use of preoperative mechanical bowel preparation with oral antibiotics (laxative solutions and antibiotics distributed in clinic before surgery). Quarterly compliance improved for 80% of process measures by the end of the study period. This study was conducted on a small surgical cohort within a select subspecialty. The

  6. Ex vivo MRI evaluation of prostate cancer: Localization and margin status prediction of prostate cancer in fresh radical prostatectomy specimens.

    Science.gov (United States)

    Heidkamp, Jan; Hoogenboom, Martijn; Kovacs, Iringo E; Veltien, Andor; Maat, Arie; Sedelaar, J P Michiel; Hulsbergen-van de Kaa, Christina A; Fütterer, Jurgen J

    2018-02-01

    To investigate the ability of high field ex vivo magnetic resonance imaging (MRI) to localize prostate cancer (PCa) and to predict the margin status in fresh radical prostatectomy (RP) specimens using histology as the reference standard. This Institutional Review Board (IRB)-approved study had written informed consent. Patients with biopsy-proved PCa and a diagnostic multiparametric 3T MRI examination of the prostate prior to undergoing RP were prospectively included. A custom-made container provided reference between the 7T ex vivo MRI obtained from fresh RP specimens and histological slicing. On ex vivo MRI, PCa was localized and the presence of positive surgical margins was determined in a double-reading session. These findings were compared with histological findings obtained from completely cut, whole-mount embedded, prostate specimens. In 12 RP specimens, histopathology revealed 36 PCa lesions, of which 17 (47%) and 20 (56%) were correlated with the ex vivo MRI in the first and second reading session, respectively. Nine of 12 (75%) index lesions were localized in the first session, in the second 10 of 12 (83%). Seven and 8 lesions of 11 lesions with Gleason score >6 and >0.5 cc were localized in the first and second session, respectively. In the first session none of the four histologically positive surgical margins (sensitivity 0%) and 9 of 13 negative margins (specificity 69%) were detected. In second session the sensitivity and specificity were 25% and 88%, respectively. Ex vivo MRI enabled accurate localization of PCa in fresh RP specimens, and the technique provided information on the margin status with high specificity. 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:439-448. © 2017 International Society for Magnetic Resonance in Medicine.

  7. Finite element simulations of electrostatic dopant potentials in thin semiconductor specimens for electron holography

    Energy Technology Data Exchange (ETDEWEB)

    Somodi, P.K.; Twitchett-Harrison, A.C.; Midgley, P.A. [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); Kardynał, B.E. [Peter Grünberg Institute 9, Forschungszentrum Jülich, D-52425 Jülich (Germany); Barnes, C.H.W. [Department of Physics, University of Cambridge, Madingley Road, Cambridge CB3 0HE (United Kingdom); Dunin-Borkowski, R.E., E-mail: rafaldb@gmail.com [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons and Peter Grünberg Institute 5, Forschungszentrum Jülich, D-52425 Jülich (Germany)

    2013-11-15

    Two-dimensional finite element simulations of electrostatic dopant potentials in parallel-sided semiconductor specimens that contain p–n junctions are used to assess the effect of the electrical state of the surface of a thin specimen on projected potentials measured using off-axis electron holography in the transmission electron microscope. For a specimen that is constrained to have an equipotential surface, the simulations show that the step in the projected potential across a p–n junction is always lower than would be predicted from the properties of the bulk device, but is relatively insensitive to the value of the surface state energy, especially for thicker specimens and higher dopant concentrations. The depletion width measured from the projected potential, however, has a complicated dependence on specimen thickness. The results of the simulations are of broader interest for understanding the influence of surfaces and interfaces on electrostatic potentials in nanoscale semiconductor devices. - Highlights: • Finite element simulations are performed to calculate electrostatic dopant potentials in TEM specimens that contain p–n junctions. • The effect of the electrical state of the specimen surface on the projected potential is assessed for equipotential specimen surfaces. • The step in projected potential is always found to be lower than the step in potential in the bulk device. • The step in projected potential is least sensitive to surface state energy for thicker specimens and higher dopant concentrations. • The depletion width measured from the projected potential has a complicated dependence on specimen thickness.

  8. Finite element simulations of electrostatic dopant potentials in thin semiconductor specimens for electron holography

    International Nuclear Information System (INIS)

    Somodi, P.K.; Twitchett-Harrison, A.C.; Midgley, P.A.; Kardynał, B.E.; Barnes, C.H.W.; Dunin-Borkowski, R.E.

    2013-01-01

    Two-dimensional finite element simulations of electrostatic dopant potentials in parallel-sided semiconductor specimens that contain p–n junctions are used to assess the effect of the electrical state of the surface of a thin specimen on projected potentials measured using off-axis electron holography in the transmission electron microscope. For a specimen that is constrained to have an equipotential surface, the simulations show that the step in the projected potential across a p–n junction is always lower than would be predicted from the properties of the bulk device, but is relatively insensitive to the value of the surface state energy, especially for thicker specimens and higher dopant concentrations. The depletion width measured from the projected potential, however, has a complicated dependence on specimen thickness. The results of the simulations are of broader interest for understanding the influence of surfaces and interfaces on electrostatic potentials in nanoscale semiconductor devices. - Highlights: • Finite element simulations are performed to calculate electrostatic dopant potentials in TEM specimens that contain p–n junctions. • The effect of the electrical state of the specimen surface on the projected potential is assessed for equipotential specimen surfaces. • The step in projected potential is always found to be lower than the step in potential in the bulk device. • The step in projected potential is least sensitive to surface state energy for thicker specimens and higher dopant concentrations. • The depletion width measured from the projected potential has a complicated dependence on specimen thickness

  9. Clinicopathologic features of incidental prostatic adenocarcinoma in radical cystoprostatectomy specimens

    Directory of Open Access Journals (Sweden)

    Vuruskan Hakan

    2011-07-01

    Full Text Available Abstract Background The aim of this study is to review all features of incidentally discovered prostate adenocarcinoma in patients undergoing radical cystoprostatectomy for bladder cancer. Methods The medical charts of 300 male patients who underwent radical cystoprostatectomy for bladder cancer between 1997 and 2005 were retrospectively reviewed. The mean age of the patients was 62 (range 51-75 years. Results Prostate adenocarcinoma was present in 60 (20% of 300 specimens. All were acinar adenocarcinoma. Of these, 40 (66.7% were located in peripheral zone, 20 (33.3% had pT2a tumor, 12 (20% had pT2b tumor, 22(36.7% had pT2c and, 6 (10% had pT3a tumor. Gleason score was 6 or less in 48 (80% patients. Surgical margins were negative in 54 (90% patients, and tumor volume was less than 0.5 cc in 23 (38.3% patients. Of the 60 incidentally detected cases of prostate adenocarcinoma 40 (66.7% were considered clinically significant. Conclusion Incidentally detected prostate adenocarcinoma is frequently observed in radical cystoprostatectomy specimens. The majority are clinically significant.

  10. Bireflectance imaging of coal and carbon specimens

    Energy Technology Data Exchange (ETDEWEB)

    Crelling, J.C. [Department of Geology, 1259 Lincoln Drive, Southern Illinois University, Carbondale, Illinois 62901 (United States); Glasspool, I.J.; Gibbins, J.R.; Seitz, M. [Department of Mechanical Engineering, Imperial College, Exhibition Road, London, SW7 2BX (United Kingdom)

    2005-11-10

    Although bireflectance measurements are routine, to date they have been limited to selected single point measurements. This study uses a 360{sup o} rotating polarizer in the incident light path combined with digital imaging to map the optical bireflectance of a polished specimen over the complete field of view, a system herein referred to as 'Bireflectance Imaging of Coal and Carbon Specimens' (BRICCS). True maximum reflectance maps and maps of polarizer angle for maximum reflectance (to identify co-ordered regions) are obtainable from the same data. A variety of coal, coke, char, graphite, and carbon/carbon specimens have been examined with the BRICCS system and the results demonstrate that the system can produce accurate maximum and apparent minimum reflectance, bireflectance, and extinction angle images. For example, flakes of natural graphite show no bireflectance along their long axis except in areas that have been strained. The images are maps showing the value of every pixel that has been calibrated by mineral reflectance standards. The maps are unique in that they show fields of view that cannot be seen by normal viewing through the microscope. For example, the bireflectance maps show the maximum difference between the maximum and apparent minimum reflectance for each of the million pixels at twenty orientations of the polarizer. (author)

  11. Procurement of Human Tissues for Research Banking in the Surgical Pathology Laboratory: Prioritization Practices at Washington University Medical Center

    Science.gov (United States)

    Chernock, Rebecca D.; Leach, Tracey A.; Kahn, Ajaz A.; Yip, James H.; Rossi, Joan; Pfeifer, John D.

    2011-01-01

    Academic hospitals and medical schools with research tissue repositories often derive many of their internal human specimen acquisitions from their site's surgical pathology service. Typically, such acquisitions come from appropriately consented tissue discards sampled from surgical resections. Because the practice of surgical pathology has patient care as its primary mission, competing needs for tissue inevitably arise, with the requirement to preserve adequate tissue for clinical diagnosis being paramount. A set of best-practice gross pathology guidelines are summarized here, focused on the decision for tissue banking at the time specimens are macroscopically evaluated. These reflect our collective experience at Washington University School of Medicine, and are written from the point of view of our site biorepository. The involvement of trained pathology personnel in such procurements is very important. These guidelines reflect both good surgical pathology practice (including the pathologic features characteristic of various anatomic sites) and the typical objectives of research biorepositories. The guidelines should be helpful to tissue bank directors, and others charged with the procurement of tissues for general research purposes. We believe that appreciation of these principles will facilitate the partnership between surgical pathologists and biorepository directors, and promote both good patient care and strategic, value-added banking procurements. PMID:23386925

  12. The measurement of power losses at high magnetic field densities or at small cross-section of test specimen using the averaging

    CERN Document Server

    Gorican, V; Hamler, A; Nakata, T

    2000-01-01

    It is difficult to achieve sufficient accuracy of power loss measurement at high magnetic field densities where the magnetic field strength gets more and more distorted, or in cases where the influence of noise increases (small specimen cross section). The influence of averaging on the accuracy of power loss measurement was studied on the cast amorphous magnetic material Metglas 2605-TCA. The results show that the accuracy of power loss measurements can be improved by using the averaging of data acquisition points.

  13. Specimen-specific modeling of hip fracture pattern and repair.

    Science.gov (United States)

    Ali, Azhar A; Cristofolini, Luca; Schileo, Enrico; Hu, Haixiang; Taddei, Fulvia; Kim, Raymond H; Rullkoetter, Paul J; Laz, Peter J

    2014-01-22

    Hip fracture remains a major health problem for the elderly. Clinical studies have assessed fracture risk based on bone quality in the aging population and cadaveric testing has quantified bone strength and fracture loads. Prior modeling has primarily focused on quantifying the strain distribution in bone as an indicator of fracture risk. Recent advances in the extended finite element method (XFEM) enable prediction of the initiation and propagation of cracks without requiring a priori knowledge of the crack path. Accordingly, the objectives of this study were to predict femoral fracture in specimen-specific models using the XFEM approach, to perform one-to-one comparisons of predicted and in vitro fracture patterns, and to develop a framework to assess the mechanics and load transfer in the fractured femur when it is repaired with an osteosynthesis implant. Five specimen-specific femur models were developed from in vitro experiments under a simulated stance loading condition. Predicted fracture patterns closely matched the in vitro patterns; however, predictions of fracture load differed by approximately 50% due to sensitivity to local material properties. Specimen-specific intertrochanteric fractures were induced by subjecting the femur models to a sideways fall and repaired with a contemporary implant. Under a post-surgical stance loading, model-predicted load sharing between the implant and bone across the fracture surface varied from 59%:41% to 89%:11%, underscoring the importance of considering anatomic and fracture variability in the evaluation of implants. XFEM modeling shows potential as a macro-level analysis enabling fracture investigations of clinical cohorts, including at-risk groups, and the design of robust implants. © 2013 Published by Elsevier Ltd.

  14. Preoperative MR imaging-based volume measurements of the hippocampal formation and anterior temporal lobe in epileptic patients

    International Nuclear Information System (INIS)

    Jack, C.R.; Sharbrough, F.W.; Twomey, C.; Zinsmeister, A.R.; Cascino, G.D.; Hirschorn, K.A.; Marsh, W.R.

    1989-01-01

    MR-based volume measurements of the anterior temporal lobe and hippocampal formation were performed in 36 patients who subsequently underwent surgery for medically refractory temporal lobe epilepsy. Seizure lateralization was based on standard clinical and electroencephalographic criteria. No surgical pathologic specimens contained structural lesions; epilepsy in these patients was therefore presumably due to mesial sclerosis. The right-minus-left hippocampal formation volume difference was greater than 0 in all 20 patients operated on the left side and less than 0 in all 16 patients operated on the right side. This difference completely separated the two surgical groups, while the same measurement in a group of 35 normal controls fell between the two surgical groups. Measurements of the anterior temporal to be showed a similar trend but incompletely separated controls, right- and left-sided epileptics. These results suggest that in a significant percentage of cases, MR-based volume measurements correctly identify the unilateral hippocampal atrophy that is known to occur in cases of mesial temporal sclerosis

  15. Laparoscopic specimen retrieval bags.

    Science.gov (United States)

    Smorgick, Noam

    2014-10-01

    Specimen retrieval bags have long been used in laparoscopic gynecologic surgery for contained removal of adnexal cysts and masses. More recently, the concerns regarding spread of malignant cells during mechanical morcellation of myoma have led to an additional use of specimen retrieval bags for contained "in-bag" morcellation. This review will discuss the indications for use retrieval bags in gynecologic endoscopy, and describe the different specimen bags available to date.

  16. Surgical navigation with QR codes

    Directory of Open Access Journals (Sweden)

    Katanacho Manuel

    2016-09-01

    Full Text Available The presented work is an alternative to established measurement systems in surgical navigation. The system is based on camera based tracking of QR code markers. The application uses a single video camera, integrated in a surgical lamp, that captures the QR markers attached to surgical instruments and to the patient.

  17. Use of globally unique identifiers (GUIDs) to link herbarium specimen records to physical specimens.

    Science.gov (United States)

    Nelson, Gil; Sweeney, Patrick; Gilbert, Edward

    2018-02-01

    With the advent of the U.S. National Science Foundation's Advancing Digitization of Biodiversity Collections program and related worldwide digitization initiatives, the rate of herbarium specimen digitization in the United States has expanded exponentially. As the number of electronic herbarium records proliferates, the importance of linking these records to the physical specimens they represent as well as to related records from other sources will intensify. Although a rich and diverse literature has developed over the past decade that addresses the use of specimen identifiers for facilitating linking across the internet, few implementable guidelines or recommended practices for herbaria have been advanced. Here we review this literature with the express purpose of distilling a specific set of recommendations especially tailored to herbarium specimen digitization, curation, and management. We argue that associating globally unique identifiers (GUIDs) with physical herbarium specimens and including these identifiers in all electronic records about those specimens is essential to effective digital data curation. We also address practical applications for ensuring these associations.

  18. Small specimen technique for assessing mechanical properties of metallic components

    Energy Technology Data Exchange (ETDEWEB)

    Lobo, Raquel M.; Andrade, Arnaldo H.P.; Morcelli, Aparecido E., E-mail: rmlobo@ipen.br, E-mail: morcelliae@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    Small Punch Test (SPT) is one of the most promising techniques of small specimen test, which was originally applied in testing of irradiated materials in nuclear engineering. Then it was introduced to other fields as an almost nondestructive method to measure the local mechanical properties that are difficult to be obtained using conventional mechanical tests. Most studies to date are focused on metallic materials, although SPT applications are recently spreading to other materials. The small punch test (SPT) employs small-sized specimens (for example, samples measuring 8 mm in diameter and 0.5 mm thick). The specimen is firmly clamped between two circular dies and is bi-axially strained until failure into a circular hole using a hemispherical punch. The 'load-punch displacement' record can be used to estimate the yield strength, the ultimate tensile strength, the tensile elongation, and the temperature of the ductile-to-brittle transition. Recently, some researchers are working on the use of miniature notched or pre-cracked specimens (denoted as p-SPT) to validate its geometry and dimensions for obtaining the fracture properties of metallic materials. In a first approach, the technique makes it possible to convert primary experimental data into conventional mechanical properties of a massive specimen. In this paper a comprehensive review of the different STP applications is presented with the aim of clarifying its usefulness. (author)

  19. Small specimen technique for assessing mechanical properties of metallic components

    International Nuclear Information System (INIS)

    Lobo, Raquel M.; Andrade, Arnaldo H.P.; Morcelli, Aparecido E.

    2017-01-01

    Small Punch Test (SPT) is one of the most promising techniques of small specimen test, which was originally applied in testing of irradiated materials in nuclear engineering. Then it was introduced to other fields as an almost nondestructive method to measure the local mechanical properties that are difficult to be obtained using conventional mechanical tests. Most studies to date are focused on metallic materials, although SPT applications are recently spreading to other materials. The small punch test (SPT) employs small-sized specimens (for example, samples measuring 8 mm in diameter and 0.5 mm thick). The specimen is firmly clamped between two circular dies and is bi-axially strained until failure into a circular hole using a hemispherical punch. The 'load-punch displacement' record can be used to estimate the yield strength, the ultimate tensile strength, the tensile elongation, and the temperature of the ductile-to-brittle transition. Recently, some researchers are working on the use of miniature notched or pre-cracked specimens (denoted as p-SPT) to validate its geometry and dimensions for obtaining the fracture properties of metallic materials. In a first approach, the technique makes it possible to convert primary experimental data into conventional mechanical properties of a massive specimen. In this paper a comprehensive review of the different STP applications is presented with the aim of clarifying its usefulness. (author)

  20. Urine culture - catheterized specimen

    Science.gov (United States)

    Culture - urine - catheterized specimen; Urine culture - catheterization; Catheterized urine specimen culture ... urinary tract infections may be found in the culture. This is called a contaminant. You may not ...

  1. Effect of specimen geometry on the variability in fatigue crack growth rate

    International Nuclear Information System (INIS)

    Tsuji, Hirokazu; Nakajima, Hajime; Kondo, Tatsuo

    1982-02-01

    Fatigue crack growth tests on SA 533 grade B class 1 steel were conducted in air with both contoured double cantilever beam (CDCB) specimens and compact-tension (CT) specimens for comparison, which corresponded to the ΔK constant and ΔK increasing fatigue tests respectively. The variability of the measured values was examined statistically, and possible sources of the determined variability were discussed. The variability in the ΔK increasing fatigue tests with the CT specimens was found to be substantially greater than that in the ΔK constant fatigue tests with the CDCB specimens employed in the present study. In addition, the width of the scatter as well as in the degree of deviation from the expected linearity in da/dN versus ΔK plots were found to be varied depending on the level of ΔK in the CT specimen. Based on the results, a conclusion was drawn that constant ΔK type tests should be preferred in the tests where accuracy and reproducibility of crack growth rate measurement was of particular importance. (author)

  2. HMSRP Hawaiian Monk Seal Specimen Data (includes physical specimens, collection information, status, storage locations, and laboratory results associated with individual specimens)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set includes physical specimens, paper logs and Freezerworks database of all logged information on specimens collected from Hawaiian monk seals since 1975....

  3. Anatomy and Surgical Approaches to the Rabbit Nasal Septum.

    Science.gov (United States)

    Badran, Karam W; Chang, John C; Kuan, Edward C; Wong, Brian J F

    2017-09-01

    The rabbit is the primary animal model used to investigate aspects of nasal surgery. Although several studies have used this model, none has provided a comprehensive analysis of the surgical anatomy and techniques used to gain access to the rabbit nasal fossae and septum. To describe and optimize the surgical anatomy and approach to the rabbit nasal vault and septal cartilage. In an ex vivo animal study conducted at an academic medical center, preliminary cadaveric dissections were performed on rabbit head specimens to establish familiarity with relevant anatomy and rehearse various approaches. Live Pasteurella-free New Zealand white rabbits (3.5-4.0 kg) were used to further develop this surgical technique developed here. Access of the nasal vault was gained through a midline nasal dorsum incision and creation of an osteoplastic flap with a drill. Submucosal resection was performed with preservation of the mucoperichondrium. All rabbits were monitored daily for 4 weeks in the postoperative period for signs of infection, pain, and complications. The study was conducted from June 1, 2014, to December 1, 2014. Surgical anatomy and techniques used to gain access to the rabbit nasal vault and harvest septal cartilage. Four Pasteurella-free New Zealand white rabbits (Western Organ Rabbit Co), ranging in age from 9 to 12 months and weighing between 3.5 and 4.0 kg, were used in this study. Initial dissections demonstrated the feasibility of harvesting septal cartilage while preserving the mucoperichondrial envelope. Access to the nasal vault through this 3-osteotomy approach allowed for maximal exposure to the nasal cavity bilaterally while maintaining the integrity of the mucoperichondrium following septal cartilage harvest. The maximum amount of bulk, en bloc, cartilage harvested was 1.0 × 2.5 cm. Following surgical dissection, all animals maintained adequate airway patency and support to midface structures. Furthermore, all specimens preserved the integrity of the

  4. Introducing 3-Dimensional Printing of a Human Anatomic Pathology Specimen: Potential Benefits for Undergraduate and Postgraduate Education and Anatomic Pathology Practice.

    Science.gov (United States)

    Mahmoud, Amr; Bennett, Michael

    2015-08-01

    Three-dimensional (3D) printing, a rapidly advancing technology, is widely applied in fields such as mechanical engineering and architecture. Three-dimensional printing has been introduced recently into medical practice in areas such as reconstructive surgery, as well as in clinical research. Three-dimensionally printed models of anatomic and autopsy pathology specimens can be used for demonstrating pathology entities to undergraduate medical, dental, and biomedical students, as well as for postgraduate training in examination of gross specimens for anatomic pathology residents and pathology assistants, aiding clinicopathological correlation at multidisciplinary team meetings, and guiding reconstructive surgical procedures. To apply 3D printing in anatomic pathology for teaching, training, and clinical correlation purposes. Multicolored 3D printing of human anatomic pathology specimens was achieved using a ZCorp 510 3D printer (3D Systems, Rock Hill, South Carolina) following creation of a 3D model using Autodesk 123D Catch software (Autodesk, Inc, San Francisco, California). Three-dimensionally printed models of anatomic pathology specimens created included pancreatoduodenectomy (Whipple operation) and radical nephrectomy specimens. The models accurately depicted the topographic anatomy of selected specimens and illustrated the anatomic relation of excised lesions to adjacent normal tissues. Three-dimensional printing of human anatomic pathology specimens is achievable. Advances in 3D printing technology may further improve the quality of 3D printable anatomic pathology specimens.

  5. Study of deformation evolution during failure of rock specimens using laser-based vibration measurements

    Science.gov (United States)

    Smolin, I. Yu.; Kulkov, A. S.; Makarov, P. V.; Tunda, V. A.; Krasnoveikin, V. A.; Eremin, M. O.; Bakeev, R. A.

    2017-12-01

    The aim of the paper is to analyze experimental data on the dynamic response of the marble specimen in uniaxial compression. To make it we use the methods of mathematical statistics. The lateral surface velocity evolution obtained by the laser Doppler vibrometer represents the data for analysis. The registered data were regarded as a time series that reflects deformation evolution of the specimen loaded up to failure. The revealed changes in statistical parameters were considered as precursors of failure. It is shown that before failure the deformation response is autocorrelated and reflects the states of dynamic chaos and self-organized criticality.

  6. Effectiveness of the Thoracic Pedicle Screw Placement Using the Virtual Surgical Training System: A Cadaver Study.

    Science.gov (United States)

    Hou, Yang; Lin, Yanping; Shi, Jiangang; Chen, Huajiang; Yuan, Wen

    2018-03-14

    The virtual simulation surgery has initially exhibited its promising potentials in neurosurgery training. To evaluate effectiveness of the Virtual Surgical Training System (VSTS) on novice residents placing thoracic pedicle screws in a cadaver study. A total of 10 inexperienced residents participated in this study and were randomly assigned to 2 groups. The group using VSTS to learn thoracic pedicle screw fixation was the simulation training (ST) group and the group receiving an introductory teaching session was the control group. Ten fresh adult spine specimens including 6 males and 4 females with a mean age of 58.5 yr (range: 33-72) were collected and randomly allocated to the 2 groups. After exposing anatomic structures of thoracic spine, the bilateral pedicle screw placement of T6-T12 was performed on each cadaver specimen. The postoperative computed tomography scan was performed on each spine specimen, and experienced observers independently reviewed the placement of the pedicle screws to assess the incidence of pedicle breach. The screw penetration rates of the ST group (7.14%) was significantly lower in comparison to the control group (30%, P < .05). Statistically significant difference in acceptable rates of screws also occurred between the ST (100%) and control (92.86%) group (P < .05). In addition, the average screw penetration distance in control group (2.37 mm ± 0.23 mm) was significantly greater than ST group (1.23 mm ± 0.56 mm, P < .05). The virtual reality surgical training of thoracic pedicle screw instrumentation effectively improves surgical performance of novice residents compared to those with traditional teaching method, and can help new beginners to master the surgical technique within shortest period of time.

  7. Comparison of the time taken for localised breast surgery pre- and post-introduction of intra-operative digital specimen mammography.

    Science.gov (United States)

    Carraro do Nascimento, Vinicius; Bourke, Anita G

    2018-02-01

    More than half of the patients with an impalpable malignant breast lesion have a mammographically detected and imaged-guided localisation, which can be technically challenging for the breast surgeon. Specimen imaging is used to confirm successful excision of the localised index lesion and has improved the operating list efficiency resulting in a higher number of excisions per surgical list. The aim of this study was to evaluate whether introducing IDSM (intra-operative digital specimen mammography) saved operation time for localised breast surgery. A single-centre retrospective review was undertaken to compare the operation time (from incision to wound closure) taken for excision of 114 consecutive image-guided localised impalpable breast lesions, performed using departmental specimen radiography (DSR), 6 months prior to the introduction of IDSM (Hologic, Trident ® ) in March 2013, with the theatre time taken for excision of 121 consecutive image-guided localised impalpable breast lesions in the 6 months following introduction of IDSM. There was no significant difference in mean surgical time, which were 47.8 (±27.3) minutes in the CSR group and 48.8 (±25.7) minutes in the IDSM group. We were expecting to confirm a reduction in theatre time with the introduction of IDSM. Surprisingly, no difference in operating times was demonstrated. Factors that influenced the impact of IDSM included the proximity of the imaging department to the operating theatre. © 2017 The Royal Australian and New Zealand College of Radiologists.

  8. The surgical care improvement project and prevention of post-operative infection, including surgical site infection.

    Science.gov (United States)

    Rosenberger, Laura H; Politano, Amani D; Sawyer, Robert G

    2011-06-01

    In response to inconsistent compliance with infection prevention measures, the Centers for Medicare & Medicaid Services collaborated with the U.S. Centers for Disease Control and Prevention on the Surgical Infection Prevention (SIP) project, introduced in 2002. Quality improvement measures were developed to standardize processes to increase compliance. In 2006, the Surgical Care Improvement Project (SCIP) developed out of the SIP project and its process measures. These initiatives, published in the Specifications Manual for National Inpatient Quality Measures, outline process and outcome measures. This continually evolving manual is intended to provide standard quality measures to unify documentation and track standards of care. Seven of the SCIP initiatives apply to the peri-operative period: Prophylactic antibiotics should be received within 1 h prior to surgical incision (1), be selected for activity against the most probable antimicrobial contaminants (2), and be discontinued within 24 h after the surgery end-time (3); (4) euglycemia should be maintained, with well-controlled morning blood glucose concentrations on the first two post-operative days, especially in cardiac surgery patients; (6) hair at the surgical site should be removed with clippers or by depilatory methods, not with a blade; (9) urinary catheters are to be removed within the first two post-operative days; and (10) normothermia should be maintained peri-operatively. There is strong evidence that implementation of protocols that standardize practices reduce the risk of surgical infection. The SCIP initiative targets complications that account for a significant portion of preventable morbidity as well as cost. One of the goals of the SCIP guidelines was a 25% reduction in the incidence of surgical site infections from implementation through 2010. Process measures are becoming routine, and as we practice more evidence-based medicine, it falls to us, the surgeons and scientists, to be active

  9. Development of reconstitution method for surveillance specimens using surface activated joining

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Terumi; Kaihara, Shoichiro; Yoshida, Kazuo; Sato, Akira [Ishikawajima-Harima Heavy Industries Co. Ltd., Tokyo (Japan); Onizawa, Kunio; Nishiyama, Yutaka; Fukaya, Kiyoshi; Suzuki, Masahide

    1996-03-01

    Evaluation of embrittlement of reactor vessel steel due to irradiation requires surveillance tests. However, many surveillance specimens are necessary for nuclear plants life extension. Therefore, a specimen reconstitution technique has become important to provide the many specimens for continued surveillance. A surface activated joining (SAJ) method has been developed to join various materials together at low temperatures with little deformation, and is useful to bond irradiated specimens. To assess the validity of this method, Charpy impact tests were carried out, and the characteristics caused by heating during joining were measured. The test results showed the Charpy impact values were almost the same as base materials, and surface activated joining reduced heat affected zone to less than 2 mm. (author).

  10. Intraoperative digital specimen radiography in the treatment of nonpalpable breast lesions

    Directory of Open Access Journals (Sweden)

    Vicko Ferenc

    2017-01-01

    Full Text Available Introduction/Objective. About a third of the breast lesions on mammography are clinically occult. The goals of surgical treatment are to locate, remove, and verify their presence in the removed breast tissue. Standard specimen mammography (SSM has been an official procedure for the latter, while intraoperative digital specimen radiography (IDSR was introduced recently. The aim of this study was to evaluate the use of IDSR versus SSM and possible benefits regarding the duration of the procedures (operating room occupancy, availability of digital mammography for additional number of patients, surgeon productivity, and the quality of performed services. Methods. A retrospective chart review of 109 patients who underwent IDSR for nonpalpable breast lesions was performed between January 2014 and June 2016. We compared the difference in the duration of IDSR versus SSM procedure. We also observed the number of re-excisions and evaluated time-saving in the operating room workflow. Results. The average duration of surgery in the IDSR group of patients was 51 minutes, compared to 64 minutes in the SSM group. Every IDSR procedure saved 13 minutes over the standard SSM. That would allow another 28 procedures in the same time frame, with the same quality of service compared with SSM. In that way we increased productivity by 27.5%. Additional operation/surgery was needed for histologically involved surgical margins in three cases (2.75%. Conclusion. The use of new technology resulted in the rationalization of the operative room workflow and gave better productivity. More savings were obtained through the increase of digital mammography capacity for diagnostics, decrease of anesthesia duration, and better management of human resources. The number of “true” re-excisions, involving additional surgery, remained similar after introducing IDSR.

  11. Rehydration of forensically important larval Diptera specimens.

    Science.gov (United States)

    Sanford, Michelle R; Pechal, Jennifer L; Tomberlin, Jeffery K

    2011-01-01

    Established procedures for collecting and preserving evidence are essential for all forensic disciplines to be accepted in court and by the forensic community at large. Entomological evidence, such as Diptera larvae, are primarily preserved in ethanol, which can evaporate over time, resulting in the dehydration of specimens. In this study, methods used for rehydrating specimens were compared. The changes in larval specimens with respect to larval length and weight for three forensically important blow fly (Diptera: Calliphoridae) species in North America were quantified. Phormia regina (Meigen), Cochliomyia macellaria (F.), and Chrysomya rufifacies (Macquart) third-instar larvae were collected from various decomposing animals and preserved with three preservation methods (80% ethanol, 70% isopropyl alcohol, and hot-water kill then 80% ethanol). Preservative solutions were allowed to evaporate. Rehydration was attempted with either of the following: 80% ethanol, commercial trisodium phosphate substitute solution, or 0.5% trisodium phosphate solution. All three methods partially restored weight and length of specimens recorded before preservation. Analysis of variance results indicated that effects of preservation, rehydration treatment, and collection animal were different in each species. The interaction between preservative method and rehydration treatment had a significant effect on both P. regina and C. macellaria larval length and weight. In addition, there was a significant interaction effect of collection animal on larval C. macellaria measurements. No significant effect was observed in C. rufifacies larval length or weight among the preservatives or treatments. These methods could be used to establish a standard operating procedure for dealing with dehydrated larval specimens in forensic investigations.

  12. Economic modeling of surgical disease: a measure of public health interventions.

    Science.gov (United States)

    Corlew, D Scott

    2013-07-01

    The measurement of the burden of disease and the interventions that address that burden can be done in various units. Reducing these measures to the common denominator of economic units (i.e., currency) enables comparison with other health entities, interventions, and even other fields. Economic assessment is complex, however, because of the multifactorial components of what constitutes health and what constitutes health interventions, as well as the coupling of those data to economic means. To perform economic modeling in a meaningful manner, it is necessary to: (1) define the health problem to be addressed; (2) define the intervention to be assessed; (3) define a measure of the effect of the health entity with and without the intervention (which includes defining the counterfactual); and (4) determine the appropriate method of converting the health effect to economics. This paper discusses technical aspects of how economic modeling can be done both of disease entities and of interventions. Two examples of economic modeling applied to surgical problems are then given.

  13. Device for investigating subcritical crack growth of RPV steel specimens under BWR conditions

    International Nuclear Information System (INIS)

    Anders, D.; Ahlf, J.

    1983-01-01

    An experiment is being prepared to investigate the subcritical crack growth of RPV steel specimens under cyclic load and under the environmental conditions of a BWR with regard to primary water and irradiation. The experiment will be carried out in the VAK reactor Kahl which is a boiling water reactor operating at 71 bar, 286 0 C and generating 16 MW/sub e/. The experimental setup is composed of an open frame to which a string consisting of five compact tension speciments (40 mm thickness) and connecting links is fixed. The specimen chain is set under cyclic load by a pneumatically actuated bellows unit which is attached to the frame top. Specimen strain and crack opening are measured by linear differential transformers; for temperature distribution measurements in the specimens thermocouples are applied

  14. Effect of ultraviolet light on creatinine measurement in jaundiced specimens

    International Nuclear Information System (INIS)

    Nisbet, J.A.; D'Souza, R.

    1986-01-01

    During initial evaluation of a creatinine method using the RA-1000 analyser, experiments with addition of bilirubin indicated negligible interference. However the finding of a 'zero' creatinine value in an extremely jaundiced specimen prompted to re-examine the method. In contrast to earlier findings with normal plasma containing added bilirubin, the authors found that plasma from moderately or severely jaundiced patients gave creatinine values lower than those obtained with a reference method. Since bilirubin has been implicated in the interference, the authors studied the effect of destroying bilirubin with ultraviolet light to see if this provided a practical solution to the problem. (Auth.)

  15. Perception of Surgical Faculty on the Utility of Modified Thiel Embalmed Cadavers

    Directory of Open Access Journals (Sweden)

    Ashwini C Appaji

    2017-10-01

    Full Text Available Introduction: Surgical skills training on low and high fidelity simulators have been in practice for over a decade, but due to the high cost of virtual reality simulators it is beyond the reach of institutions and trainees. Among the simulators, high fidelity simulators such as a suitably prepared human anatomical specimen would give a real feel as if doing the procedure in the living. Hence, having soft, supple cadaver with organoleptic properties is an ideal situation for training by simulation and research. To facilitate the surgical skill training and research, chemical embalming was adopted with modifications of the Thiel method, for cadaver preservation. Aim: The aim of this study was to study the perception of the surgical faculty’s experience on the utility of modified Thiel embalmed cadavers for surgical procedures. Materials and Methods: In this cross-sectional study, a feedback was taken from practicing surgeons of broad and sub specialties such as general surgery, orthopedic surgery, neurosurgery, plastic surgery, pediatric surgery, ophthalmology, ENT, OBG, Transplant surgery (n=54. A 5 point Likert scale questionnaire was used with criteria of measurements like skin color, consistency, odour, differentiation of the layers, approach to the area, joint mobility and suitability for the procedure. Results: The scores ranged from 3.9 to 4.46/5. The participants expressed satisfaction on the cadaver quality on their utility for performance of surgical procedures. They expressed that, such embalmed cadavers would be excellent for learning purpose, surgical skills training in orthopedic procedures like arthroscopy. They felt the joint mobility was good, the consistency was soft and differentiation of layers was good. Some felt the tissues were fragile and would easily give away losing their strength. Conclusion: Thiel embalmed cadavers retain their organoleptic properties and hence facilitate surgical skills training. The thiel embalmed

  16. Specimen preparation of irradiated materials for examination in the atom probe field ion microscope

    International Nuclear Information System (INIS)

    Russell, K.F.; Miller, M.K.

    1994-01-01

    The atom probe field ion microscope (APFIM) requires specimens in the form of ultrasharp needles. Basic protective measures used to reduce exposure druing specimen preparation are discussed. The low-level radioactive specimen blanks may be made using a two-stage electropolishing process using a thin layer of electrolyte floating on a denser inert liquid; this produces a necked region and eventually two specimens from each single blank. The amount of material handled may also be reduced using a micropolishing technique to repolish blunt or fractured specimens. Control of contamination and possible spills is discussed

  17. Experimental technologies comparison for strain measurement of a composite main landing gear bay specimen

    Science.gov (United States)

    Viscardi, Massimo; Arena, Maurizio; Ciminello, Monica; Guida, Michele; Meola, Carosena; Cerreta, Pietro

    2018-03-01

    The development of advanced monitoring system for strain measurements on aeronautical components remain an important target both when related to the optimization of the lead-time and cost for part validation, allowing earlier entry into service, and when related to the implementation of advanced health monitoring systems dedicated to the in-service parameters verification and early stage detection of structural problems. The paper deals with the experimental testing of a composite samples set of the main landing gear bay for a CS-25 category aircraft, realized through an innovative design and production process. The test have represented a good opportunity for direct comparison of different strain measurement techniques: Strain Gauges (SG) and Fibers Bragg Grating (FBG) have been used as well as non-contact techniques, specifically the Digital Image Correlation (DIC) and Infrared (IR) thermography applied where possible in order to highlight possible hot-spot during the tests. The crucial points identification on the specimens has been supported by means of advanced finite element simulations, aimed to assessment of the structural strength and deformation as well as to ensure the best performance and the global safety of the whole experimental campaign.

  18. A Study on Mechanical behavior of Tensile Specimen Fabricated by Laser Cutting

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Y. G.; Kim, G. S.; Baik, S. J.; Baek, S. Y. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The mechanical testing data are required for the assessment of dry storage of the spent nuclear fuel. Laser cutting system could be useful tools for material processing such as cutting in radioactive environment due to non-contact nature, ease in handling and the laser cutting process is most advantageous, offering the narrow kerf width and heat affected zone by using small beam spot diameter. The feasibility of the laser cutting system was demonstrated for the fabrication of various types of the unirradiated cladding with and without oxide layer on the specimens. In the present study, the dimensional measurement and tensile test were conducted to investigate the mechanical behavior of the axial tensile test specimens depending on the material processing methods in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser cutting system was used to fabricate the tensile test specimens, and the mechanical behavior was investigated using the dimensional measurement and tensile test. It was shown that the laser beam machining could be a useful tool to fabricate the specimens and this technique will be developed for the fabrication of various types of irradiated specimens in a hotcell.

  19. A Study on Mechanical behavior of Tensile Specimen Fabricated by Laser Cutting

    International Nuclear Information System (INIS)

    Jin, Y. G.; Kim, G. S.; Baik, S. J.; Baek, S. Y.

    2016-01-01

    The mechanical testing data are required for the assessment of dry storage of the spent nuclear fuel. Laser cutting system could be useful tools for material processing such as cutting in radioactive environment due to non-contact nature, ease in handling and the laser cutting process is most advantageous, offering the narrow kerf width and heat affected zone by using small beam spot diameter. The feasibility of the laser cutting system was demonstrated for the fabrication of various types of the unirradiated cladding with and without oxide layer on the specimens. In the present study, the dimensional measurement and tensile test were conducted to investigate the mechanical behavior of the axial tensile test specimens depending on the material processing methods in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser cutting system was used to fabricate the tensile test specimens, and the mechanical behavior was investigated using the dimensional measurement and tensile test. It was shown that the laser beam machining could be a useful tool to fabricate the specimens and this technique will be developed for the fabrication of various types of irradiated specimens in a hotcell

  20. Percutaneous computed tomography-guided core needle biopsy of soft tissue tumors: results and correlation with surgical specimen analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chojniak, Rubens; Grigio, Henrique Ramos; Bitencourt, Almir Galvao Vieira; Pinto, Paula Nicole Vieira; Tyng, Chiang J.; Cunha, Isabela Werneck da; Aguiar Junior, Samuel; Lopes, Ademar, E-mail: chojniak@uol.com.br [Hospital A.C. Camargo, Sao Paulo, SP (Brazil)

    2012-09-15

    Objective: To evaluate the efficacy of percutaneous computed tomography (CT)-guided core needle biopsy of soft tissue tumors in obtaining appropriate samples for histological analysis, and compare its diagnosis with the results of the surgical pathology as available. Materials and Methods: The authors reviewed medical records, imaging and histological reports of 262 patients with soft-tissue tumors submitted to CT-guided core needle biopsy in an oncologic reference center between 2003 and 2009. Results: Appropriate samples were obtained in 215 (82.1%) out of the 262 patients. The most prevalent tumors were sarcomas (38.6%), metastatic carcinomas (28.8%), benign mesenchymal tumors (20.5%) and lymphomas (9.3%). Histological grading was feasible in 92.8% of sarcoma patients, with the majority of them (77.9%) being classified as high grade tumors. Out of the total sample, 116 patients (44.3%) underwent surgical excision and diagnosis confirmation. Core biopsy demonstrated 94.6% accuracy in the identification of sarcomas, with 96.4% sensitivity and 89.5% specificity. A significant intermethod agreement about histological grading was observed between core biopsy and surgical resection (p < 0.001; kappa = 0.75). Conclusion: CT-guided core needle biopsy demonstrated a high diagnostic accuracy in the evaluation of soft tissue tumors as well as in the histological grading of sarcomas, allowing an appropriate therapeutic planning (author)

  1. Multi-material 3D Models for Temporal Bone Surgical Simulation.

    Science.gov (United States)

    Rose, Austin S; Kimbell, Julia S; Webster, Caroline E; Harrysson, Ola L A; Formeister, Eric J; Buchman, Craig A

    2015-07-01

    A simulated, multicolor, multi-material temporal bone model can be created using 3-dimensional (3D) printing that will prove both safe and beneficial in training for actual temporal bone surgical cases. As the process of additive manufacturing, or 3D printing, has become more practical and affordable, a number of applications for the technology in the field of Otolaryngology-Head and Neck Surgery have been considered. One area of promise is temporal bone surgical simulation. Three-dimensional representations of human temporal bones were created from temporal bone computed tomography (CT) scans using biomedical image processing software. Multi-material models were then printed and dissected in a temporal bone laboratory by attending and resident otolaryngologists. A 5-point Likert scale was used to grade the models for their anatomical accuracy and suitability as a simulation of cadaveric and operative temporal bone drilling. The models produced for this study demonstrate significant anatomic detail and a likeness to human cadaver specimens for drilling and dissection. Simulated temporal bones created by this process have potential benefit in surgical training, preoperative simulation for challenging otologic cases, and the standardized testing of temporal bone surgical skills. © The Author(s) 2015.

  2. Comparison of a new hydro-surgical technique to traditional methods for the preparation of full-thickness skin grafts from canine cadaveric skin and report of a single clinical case.

    Science.gov (United States)

    Townsend, F I; Ralphs, S C; Coronado, G; Sweet, D C; Ward, J; Bloch, C P

    2012-01-01

    To compare the hydro-surgical technique to traditional techniques for removal of subcutaneous tissue in the preparation of full-thickness skin grafts. Ex vivo experimental study and a single clinical case report. Four canine cadavers and a single clinical case. Four sections of skin were harvested from the lateral flank of recently euthanatized dogs. Traditional preparation methods used included both a blade or scissors technique, each of which were compared to the hydro-surgical technique individually. Preparation methods were compared based on length of time for removal of the subcutaneous tissue from the graft, histologic grading, and measurable thickness as compared to an untreated sample. The hydro-surgical technique had the shortest skin graft preparation time as compared to traditional techniques (p = 0.002). There was no significant difference in the histological grading or measurable subcutaneous thickness between skin specimens. The hydro-surgical technique provides a rapid, effective debridement of subcutaneous tissue in the preparation of full-thickness skin grafts. There were not any significant changes in histological grade and subcutaneous tissue remaining among all treatment types. Additionally the hydro-surgical technique was successfully used to prepare a full-thickness meshed free skin graft in the reconstruction of a traumatic medial tarsal wound in a dog.

  3. Histopathological Study of Splenectomy Specimens with Correlation with Age, Sex, and Cause of Splenectomy.

    Directory of Open Access Journals (Sweden)

    Dr Hiral Patel

    2016-12-01

    Full Text Available Spleen is mysterious organ. It can be troublesome specimen for surgical pathologist due to discordance between patient’s clinical condition and perceived finding. The weight of spleen is about 150 grams and lies beneath 9th to 12th thoracic rib in healthy adult and between fundus of stomach & diaphragm. It composed of red pulp (76-79% and white pulp (5-20% which are separated by marginal zone. A total of 100 cases were studied at histopathology section of our laboratory during the period of January 2015 to December 2015. The specimens were received in 10% neutral buffer formalin with duly filled request form. All specimens were examined macroscopically. After routine processing the sections were stained with routine haematoxylin and eosin stain. The most common age group to be affected is 3rd decade (29%, next was 4th decade (23% with slightly male predominance. Male: female ratio is 1.3:1. Most common cause for splenectomy was portal hypertension (33% followed by trauma (15%. Most common microscopic finding is fibrocongestive splenomegaly (68% which is correlated with clinical and radiological finding. In adult Portal hypertension as a hepatic cause and in paediatric age group thalassemia is the most common indication for splenectomy.

  4. Molecular classification of endometrial carcinoma on diagnostic specimens is highly concordant with final hysterectomy: Earlier prognostic information to guide treatment.

    Science.gov (United States)

    Talhouk, Aline; Hoang, Lien N; McConechy, Melissa K; Nakonechny, Quentin; Leo, Joyce; Cheng, Angela; Leung, Samuel; Yang, Winnie; Lum, Amy; Köbel, Martin; Lee, Cheng-Han; Soslow, Robert A; Huntsman, David G; Gilks, C Blake; McAlpine, Jessica N

    2016-10-01

    Categorization and risk stratification of endometrial carcinomas is inadequate; histomorphologic assessment shows considerable interobserver variability, and risk of metastases and recurrence can only be derived after surgical staging. We have developed a Proactive Molecular Risk classification tool for Endometrial cancers (ProMisE) that identifies four distinct prognostic subgroups. Our objective was to assess whether molecular classification could be performed on diagnostic endometrial specimens obtained prior to surgical staging and its concordance with molecular classification performed on the subsequent hysterectomy specimen. Sequencing of tumors for exonuclease domain mutations (EDMs) in POLE and immunohistochemistry for mismatch repair (MMR) proteins and p53 were applied to both pre- and post-staging archival specimens from 60 individuals to identify four molecular subgroups: MMR-D, POLE EDM, p53 wild type, p53 abn (abnormal). Three gynecologic subspecialty pathologists assigned histotype and grade to a subset of samples. Concordance of molecular and clinicopathologic subgroup assignments were determined, comparing biopsy/curetting to hysterectomy specimens. Complete molecular and pathologic categorization was achieved in 57 cases. Concordance metrics for pre- vs. post-staging endometrial samples categorized by ProMisE were highly favorable; average per ProMisE class sensitivity(0.9), specificity(0.96), PPV(0.9), NPV(0.96) and kappa statistic 0.86(95%CI, 0.72-0.93), indicating excellent agreement. We observed the highest level of concordance for 'p53 abn' tumors, the group associated with the worst prognosis. In contrast, grade and histotype assignment from original pathology reports pre- vs. post-staging showed only moderate levels of agreement (kappa=0.55 and 0.44 respectively); even with subspecialty pathology review only moderate levels of agreement were observed. Molecular classification can be achieved on diagnostic endometrial samples and accurately

  5. 3D printing from microfocus computed tomography (micro-CT) in human specimens: education and future implications.

    Science.gov (United States)

    Shelmerdine, Susan C; Simcock, Ian C; Hutchinson, John Ciaran; Aughwane, Rosalind; Melbourne, Andrew; Nikitichev, Daniil I; Ong, Ju-Ling; Borghi, Alessandro; Cole, Garrard; Kingham, Emilia; Calder, Alistair D; Capelli, Claudio; Akhtar, Aadam; Cook, Andrew C; Schievano, Silvia; David, Anna; Ourselin, Sebastian; Sebire, Neil J; Arthurs, Owen J

    2018-06-14

    Microfocus CT (micro-CT) is an imaging method that provides three-dimensional digital data sets with comparable resolution to light microscopy. Although it has traditionally been used for non-destructive testing in engineering, aerospace industries and in preclinical animal studies, new applications are rapidly becoming available in the clinical setting including post-mortem fetal imaging and pathological specimen analysis. Printing three-dimensional models from imaging data sets for educational purposes is well established in the medical literature, but typically using low resolution (0.7 mm voxel size) data acquired from CT or MR examinations. With higher resolution imaging (voxel sizes below 1 micron, printing of micro-CT imaged specimens can provide insight into craniofacial surgical applications, developmental cardiac anatomy, placental imaging, archaeological remains and high-resolution bone imaging. We conclude with other potential future usages of this emerging technique.

  6. Comprehensive Surgical Coaching Enhances Surgical Skill in the Operating Room: A Randomized Controlled Trial.

    Science.gov (United States)

    Bonrath, Esther M; Dedy, Nicolas J; Gordon, Lauren E; Grantcharov, Teodor P

    2015-08-01

    The aim of the study was to determine whether individualized coaching improved surgical technical skill in the operating room to a higher degree than current residency training. Clinical training in the operating room is a valuable opportunity for surgeons to acquire skill and knowledge; however, it often remains underutilized. Coaching has been successfully used in various industries to enhance performance, but its role in surgery has been insufficiently investigated. This randomized controlled trial was conducted at one surgical training program. Trainees undergoing a minimally invasive surgery rotation were randomized to either conventional training (CT) or comprehensive surgical coaching (CSC). CT included ward and operating room duties, and regular departmental teaching sessions. CSC comprised performance analysis, debriefing, feedback, and behavior modeling. Primary outcome measures were technical performance as measured on global and procedure-specific rating scales, and surgical safety parameters, measured by error count. Operative performance was assessed by blinded video analysis of the first and last cases recorded by the participants during their rotation. Twenty residents were randomized and 18 completed the study. At posttraining the CSC group (n = 9) scored significantly higher on a procedure-specific skill scale compared with the CT group (n = 9) [median, 3.90 (interquartile range, 3.68-4.30) vs 3.60 (2.98-3.70), P = 0.017], and made fewer technical errors [10 (7-13) vs 18 (13-21), P = 0.003]. Significant within-group improvements for all skill metrics were only noted in the CSC group. Comprehensive surgical coaching enhances surgical training and results in skill acquisition superior to conventional training.

  7. Prediction of retained residual stresses in laboratory fracture mechanics specimens extracted from welded components

    International Nuclear Information System (INIS)

    Hurlston, R.G.; Sherry, A.H.; James, P.; Sharples, J.K.

    2015-01-01

    The measurement of weld material fracture toughness properties is important for the structural integrity assessment of engineering components. However, welds can contain high levels of residual stress and these can be retained in fracture mechanics specimens, particularly when machined from non-stress relieved welds. Retained residual stresses can make the measurement of valid fracture toughness properties difficult. This paper describes the results of analytical work undertaken to investigate factors that can influence the magnitude and distribution of residual stresses retained in fracture mechanics specimen blanks extracted from as-welded ferritic and austenitic stainless steel plates. The results indicate that significant levels of residual stress can be retained in specimen blanks prior to notching, and that the magnitude and distribution of stress is dependent upon material properties, specimen geometry and size, and extraction location through the thickness of the weld. Finite element modelling is shown to provide a useful approach for estimating the level and distributions of retained residual stresses. A new stress partitioning approach has been developed to estimate retained stress levels and results compare favourably with FE analysis and available experimental data. The approach can help guide the selection of specimen geometry and machining strategies to minimise the level of residual stresses retained in fracture mechanics specimen blanks extracted from non stress-relieved welds and thus improve the measurement of weld fracture toughness properties. - Highlights: • A simplified method for generating realistic weld residual stresses has been developed. • It has been shown that significant levels of residual stress can be retained within laboratory fracture mechanics specimens. • The level and distribution is dependant upon material, specimen type, specimen size and extraction location. • A method has been developed to allow estimates of the

  8. Rapid determination of resistance to antibiotics in surgical clinical practice based on the measurement of radioactive carbon dioxide

    International Nuclear Information System (INIS)

    Alant, O.; Jaszsagi-Nagy, E.; Lendvay, J.; Schmidt, M.

    1978-01-01

    For the objective choice of an antibiotic a method is needed which is capable of giving informations with an essentially shorter time delay than that of the conventional bacteriological tests i.e. practically in a few hours concerning the sensitivity to the tested antibiotic of the pathogen germ cultured from the sample withdrawn from the patient under surgical treatment. The new measurement method is based on the incubation of the test material in an adequate medium containing glucose labelled with C-14 as only sugar source. The amount of the formed 14 CO 2 is proportional to the multiplication rate of the bacterium. Experience observed with 312 surgical patients indicated that the sensitivity to an antibiotic agent can be determined in 4-6 hours from the septic intergrowth or from the discharge obtained during the surgical action and in the case of chronical diseases the successfulness of the treatment with the antibiotic can be established precisely. The equipment needed for the tests is simple and the measurements can be carried out readily in hospital laboratories. (P.J.)

  9. Finite element simulations of electrostatic dopant potentials in thin semiconductor specimens for electron holography.

    Science.gov (United States)

    Somodi, P K; Twitchett-Harrison, A C; Midgley, P A; Kardynał, B E; Barnes, C H W; Dunin-Borkowski, R E

    2013-11-01

    Two-dimensional finite element simulations of electrostatic dopant potentials in parallel-sided semiconductor specimens that contain p-n junctions are used to assess the effect of the electrical state of the surface of a thin specimen on projected potentials measured using off-axis electron holography in the transmission electron microscope. For a specimen that is constrained to have an equipotential surface, the simulations show that the step in the projected potential across a p-n junction is always lower than would be predicted from the properties of the bulk device, but is relatively insensitive to the value of the surface state energy, especially for thicker specimens and higher dopant concentrations. The depletion width measured from the projected potential, however, has a complicated dependence on specimen thickness. The results of the simulations are of broader interest for understanding the influence of surfaces and interfaces on electrostatic potentials in nanoscale semiconductor devices. © 2013 Elsevier B.V. All rights reserved.

  10. Janka hardness using nonstandard specimens

    Science.gov (United States)

    David W. Green; Marshall Begel; William Nelson

    2006-01-01

    Janka hardness determined on 1.5- by 3.5-in. specimens (2×4s) was found to be equivalent to that determined using the 2- by 2-in. specimen specified in ASTM D 143. Data are presented on the relationship between Janka hardness and the strength of clear wood. Analysis of historical data determined using standard specimens indicated no difference between side hardness...

  11. Assessment of plastic flow and fracture properties with small specimens test techniques for IFMIF-designed specimens

    International Nuclear Information System (INIS)

    Spaetig, P.; Campitelli, E.N.; Bonade, R.; Baluc, N.

    2005-01-01

    The primary mission of the International Fusion Material Irradiation Facility (IFMIF) is to generate a material database to be used for the design of various components, for the licensing and for the assessment of the safe operation of a demonstration fusion reactor. IFMIF is an accelerator-based high-energy neutron source whose irradiation volume is quite limited (0.5 l for the high fluence volume). This requires the use of small specimens to measure the irradiation-induced changes on the physical and mechanical properties of materials. In this paper, we developed finite element models to better analyze the results obtained with two different small specimen test techniques applied to the tempered martensitic steel F82H-mod. First, one model was used to reconstruct the load-deflection curves of small ball punch tests, which are usually used to extract standard tensile parameters. It was shown that a reasonable assessment of the overall plastic flow can be done with small ball punch tests. Second, we investigated the stress field sensitivity at a crack tip to the constitutive behavior, for a crack modeled in plane strain, small-scale yielding and fracture mode I conditions. Based upon a local criterion for cleavage, that appears to be the basis to account for the size and geometry effects on fracture toughness, we showed that the details of the constitutive properties play a key role in modeling the irradiation-induced fracture toughness changes. Consequently, we suggest that much more attention and efforts have to be paid in investigating the post-yield behavior of the irradiated specimens and, in order to reach this goal, we recommend the use of not only tensile specimens but also that of compression ones in the IFMIF irradiation matrices. (author)

  12. A new contrast agent for radiological and dissection studies of the arterial network of anatomic specimens.

    Science.gov (United States)

    Bulla, A; Casoli, C; Farace, F; Mazzarello, V; De Luca, L; Rubino, C; Montella, A

    2014-01-01

    The aim of the present study is to propose a new contrast agent that can be easily applied both to CT and dissection studies to replace lead oxide based formulas for comparative anatomical analyses of the vascularisation of cadaveric specimens. The infusion material was an epoxy resin, especially modified by the addition of barium sulphate to enhance its radiopacity. The final copolymer was toxicologically safe. To test the properties of the new material, several cadaveric limb injections were performed. The injected specimens were both CT scanned to perform 3D vascular reconstructions and dissected by anatomical planes. There was a perfect correspondence between the image studies and the dissections: even the smallest arteries on CT scan can be identified on the specimen and vice versa. The properties of the epoxy allowed an easy dissection of the vessels. The new imaging techniques available today, such as CT scan, can evaluate the vascular anatomy in high detail and 3D. This new contrast agent may help realising detailed vascular studies comparing CT scan results with anatomical dissections. Moreover, it may be useful for teaching surgical skills in the field of plastic surgery.

  13. [Protective measures in laparoscopic resection for upper or mid rectal cancer and sigmoid colon cancer with transrectal specimen extraction surgery].

    Science.gov (United States)

    Fu, Chuangang; Zhou, Zhuqing; Han, Junyi; Lu, Bin; Gao, Wei; Zhu, Zhe; Jiang, Qixin; Ji, Fang; Du, Tao

    2017-10-25

    To introduce the use of a self-made specimen protective sleeve in laparoscopic resection for upper or mid rectal cancer and sigmoid colon cancer with transrectal specimen extraction surgery and the improvement of implantation method, so as to avoid and reduce bacterial contamination and tumor cell dissemination in abdominal cavity. During June 2015 and May 2017, 48 cases of high located rectal or sigmoid colon cancer were operated laparoscopically with natural orifices specimen extraction surgery (NOSES) using a self-made specimen protecting sleeve. Operation indication: (1) Rectum and sigmoid colon cancer with the distance of more than 6 cm from tumor inferior margin to dentate line. (2) The maximum diameter of intestine together with mesangial and tumor <7 cm by intraoperative judgment. (3) No anal and distal rectal surgery, no anorectal stenosis or lack of expansion capacity caused by trauma. (4) No ulcerative colitis, Crohn's disease or radiation proctitis. After transecting the rectum, the specimen protective sleeve was inserted through the right lower 12 mm main Trocar (This sleeve was tailored from the laparoscopic protective sleeve produced by China 3L Corporation, which was intercepted with 25-35 cm from one end of the sleeve according to the length of distal rectal retention. One end was ligated and the other was open with a ligature band. About 5 ml paraffin oil was used to rinse and lubricate during the operation). The rectal stump retained 7-8 cm in abdominal cavity. The transanal ligation part of the protective sleeve was cut off, then the stapler nail seat was inserted and specimen was pull out through the sleeve and rectum. There were 30 males and 18 females. The average age was (64.5±14.1) years, the BMI was (25.4±3.9) kg/m 2 , the tumor diameter was (3.3±1.1) cm, the maximum diameter of specimen was (5.4±1.5) cm and the length of specimen was (18.6±4.3) cm. Among these 48 cases, specimens of 36 patients were pulled out through inside of the

  14. LPTR irradiation of LLL vanadium tensile specimens and LLL Nb--1Zr tensile specimens

    International Nuclear Information System (INIS)

    MacLean, S.C.; Rowe, C.L.

    1977-01-01

    The LPTR irradiation of 14 LLL vanadium tensile specimens and 14 LLL Nb-1Zr tensile specimens is described. Sample packaging, the irradiation schedule and neutron fluences for three energy ranges are given

  15. Georeferencing Animal Specimen Datasets

    NARCIS (Netherlands)

    van Erp, M.G.J.; Hensel, R.; Ceolin, D.; van der Meij, M.

    2014-01-01

    For biodiversity research, the field of study that is concerned with the richness of species of our planet, it is of the utmost importance that the location of an animal specimen find is known with high precision. Due to specimens often having been collected over the course of many years, their

  16. A simple method for the prevention of endometrial autolysis in hysterectomy specimens.

    Science.gov (United States)

    Houghton, J P; Roddy, S; Carroll, S; McCluggage, W G

    2004-03-01

    Uteri are among the most common surgical pathology specimens. Assessment of the endometrium is often difficult because of pronounced tissue autolysis. This study describes a simple method to prevent endometrial autolysis and aid in interpretation of the endometrium. Sixty uteri were injected with formalin using a needle and syringe directed alongside a probe, which was inserted through the external cervical os into the endometrial cavity. Injection was performed on the same day as removal of the uterus. As controls, 60 uteri that were not injected with formalin were examined. The degree of endometrial autolysis was assessed on a four point scale (0-3), with a score of 0 representing no or minimal autolysis and a score of 3 representing extensive autolysis, such that histological interpretation of the endometrium was impossible. In the injected group, the number of cases with scores of 0, 1, 2, and 3 was 42, 13, four, and one, respectively. The corresponding values for the control group were 17, 23, eight, and 12, respectively. This was highly significant (p autolysis in uteri injected with formalin. The use of this simple procedure should be encouraged in hysterectomy specimens.

  17. Single specimen fracture toughness determination procedure using instrumented impact test

    International Nuclear Information System (INIS)

    Rintamaa, R.

    1993-04-01

    In the study a new single specimen test method and testing facility for evaluating dynamic fracture toughness has been developed. The method is based on the application of a new pendulum type instrumented impact tester equipped with and optical crack mouth opening displacement (COD) extensometer. The fracture toughness measurement technique uses the Double Displacement Ratio (DDR) method, which is based on the assumption that the specimen is deformed as two rigid arms that rotate around an apparent centre of rotation. This apparent moves as the crack grows, and the ratio of COD versus specimen displacement changes. As a consequence the onset ductile crack initiation can be detected on the load-displacement curve. Thus, an energy-based fracture toughness can be calculated. In addition the testing apparatus can use specimens with the Double ligament size as compared with the standard Charpy specimen which makes the impact testing more appropriate from the fracture mechanics point of view. The novel features of the testing facility and the feasibility of the new DDR method has been verified by performing an extensive experimental and analytical study. (99 refs., 91 figs., 27 tabs.)

  18. Application of small specimens to fracture mechanics characterization of irradiated pressure vessel steels

    International Nuclear Information System (INIS)

    Sokolov, M.A.; Wallin, K.; McCabe, D.E.

    1996-01-01

    In this study, precracked Charpy V-notch (PCVN) specimens were used to characterize the fracture toughness of unirradiated and irradiated reactor pressure vessel steels in the transition region by means of three-point static bending. Fracture toughness at cleavage instability was calculated in terms of elastic-plastic K Jc values. A statistical size correction based upon weakest-link theory was performed. The concept of a master curve was applied to analyze fracture toughness properties. Initially, size-corrected PCVN data from A 533 grade B steel, designated HSST Plate O2, were used to position the master curve and a 5% tolerance bound for K Jc data. By converting PCVN data to IT compact specimen equivalent K Jc data, the same master curve and 5% tolerance bound curve were plotted against the Electric Power Research Institute valid linear-elastic K Jc database and the ASME lower bound K Ic curve. Comparison shows that the master curve positioned by testing several PCVN specimens describes very well the massive fracture toughness database of large specimens. These results give strong support to the validity of K Jc with respect to K Ic in general and to the applicability of PCVN specimens to measure fracture toughness of reactor vessel steels in particular. Finally, irradiated PCVN specimens of other materials were tested, and the results are compared to compact specimen data. The current results show that PCVNs demonstrate very good capacity for fracture toughness characterization of reactor pressure vessel steels. It provides an opportunity for direct measurement of fracture toughness of irradiated materials by means of precracking and testing Charpy specimens from surveillance capsules. However, size limits based on constraint theory restrict the operational test temperature range for K Jc data from PCVN specimens. 13 refs., 8 figs., 1 tab

  19. Demonstration of transoral robotic supraglottic laryngectomy and total laryngectomy in cadaveric specimens using the Medrobotics Flex System.

    Science.gov (United States)

    Funk, Emily; Goldenberg, David; Goyal, Neerav

    2017-06-01

    Current management of laryngeal malignancies is associated with significant morbidity. Application of minimally invasive transoral techniques may reduce the morbidity associated with traditional procedures. The purpose of this study was to present our investigation of the utility of a novel flexible robotic system for transoral supraglottic laryngectomy and total laryngectomy. Transoral total laryngectomy and transoral supraglottic laryngectomy were performed in cadaveric specimens using the Flex Robotic System (Medrobotics, Raynham, MA). All procedures were completed successfully in the cadaveric models. The articulated endoscope allowed for access to the desired surgical site. Flexible instruments enabled an atraumatic approach and allowed for precise surgical technique. Access to deep anatomic structures remains problematic using current minimally invasive robotic approaches. Improvements in visualization and access to the laryngopharyngeal complex offered by this system may improve surgical applications to the larynx. This study demonstrates the technical feasibility using the Flex Robotic System for transoral robotic supraglottic laryngectomy and total laryngectomy. © 2017 Wiley Periodicals, Inc. Head Neck 39: 1218-1225, 2017. © 2017 Wiley Periodicals, Inc.

  20. Fracture toughness of Charpy-size compound specimens and its application in engineering

    International Nuclear Information System (INIS)

    Zhang, X.P.; Shi, Y.W.

    1994-01-01

    The use of a pre-cracked Charpy-size specimen with a side-groove to evaluate the fracture toughness of materials has been researched and considered. This method not only satisfies the demand for small-size specimens in surveillance tests of fracture toughness but also avoids using complicated physical methods to monitor the initial conditions of crack propagation. For most materials this method has solved the problem in which the small-size specimen did not satisfy the valid conditions of a fracture toughness measurement. In order to obtain more information from neutron-irradiated sample specimens and raise the reliability of fracture toughness surveillance tests, it has been considered more important to repeatedly exploit the broken Charpy-size specimen tested in the surveillance test, and to make it renewable. In this work, on the renewing design and utilization of Charpy-size specimens, nine data on fracture toughness can be obtained from one pre-cracked side-grooved Charpy-size specimen, while at present usually only one to three data on fracture toughness can be obtained from one Charpy-size specimen. Thus, it is found that the new method would improve the reliability of fracture toughness surveillance testing and evaluation. In addition, some factors that affect the optimum design of pre-cracked deep side-groove Charpy-size compound specimens have also been discussed. (author)

  1. Clinical relevance of DNA microarray analyses using archival formalin-fixed paraffin-embedded breast cancer specimens

    International Nuclear Information System (INIS)

    Sadi, Al Muktafi; Wang, Dong-Yu; Youngson, Bruce J; Miller, Naomi; Boerner, Scott; Done, Susan J; Leong, Wey L

    2011-01-01

    The ability of gene profiling to predict treatment response and prognosis in breast cancers has been demonstrated in many studies using DNA microarray analyses on RNA from fresh frozen tumor specimens. In certain clinical and research situations, performing such analyses on archival formalin fixed paraffin-embedded (FFPE) surgical specimens would be advantageous as large libraries of such specimens with long-term follow-up data are widely available. However, FFPE tissue processing can cause fragmentation and chemical modifications of the RNA. A number of recent technical advances have been reported to overcome these issues. Our current study evaluates whether or not the technology is ready for clinical applications. A modified RNA extraction method and a recent DNA microarray technique, cDNA-mediated annealing, selection, extension and ligation (DASL, Illumina Inc) were evaluated. The gene profiles generated from FFPE specimens were compared to those obtained from paired fresh fine needle aspiration biopsies (FNAB) of 25 breast cancers of different clinical subtypes (based on ER and Her2/neu status). Selected RNA levels were validated using RT-qPCR, and two public databases were used to demonstrate the prognostic significance of the gene profiles generated from FFPE specimens. Compared to FNAB, RNA isolated from FFPE samples was relatively more degraded, nonetheless, over 80% of the RNA samples were deemed suitable for subsequent DASL assay. Despite a higher noise level, a set of genes from FFPE specimens correlated very well with the gene profiles obtained from FNAB, and could differentiate breast cancer subtypes. Expression levels of these genes were validated using RT-qPCR. Finally, for the first time we correlated gene expression profiles from FFPE samples to survival using two independent microarray databases. Specifically, over-expression of ANLN and KIF2C, and under-expression of MAPT strongly correlated with poor outcomes in breast cancer patients. We

  2. Homemade specimen retrieval bag for laparoscopic cholecystectomy: A solution in the time of fiscal crisis.

    Science.gov (United States)

    Stavrou, George; Fotiadis, Kyriakos; Panagiotou, Dimitrios; Faitatzidou, Afroditi; Kotzampassi, Katerina

    2015-05-01

    Due to the current economic crisis in Greece, major cutbacks on healthcare costs have been imposed, resulting in a shortage of surgical supplies, including laparoscopic materials. In an attempt to reduce costs, we developed a homemade specimen retrieval bag for laparoscopic cholecystectomy. We used the polyethylene bag containing the catheter of a Redon drainage set. The bag was cut in half and pleated longitudinally; then, the gallbladder was placed in the bag and removed through the umbilicus with a grasping forceps. From September 2011 to June 2012, we used our homemade bag on 85 patients undergoing laparoscopic cholecystectomy. No rupture, accidental opening, or bile leak was observed. The learning curve was found to be five cases. Our homemade specimen retrieval bag seems to be a safe, effective, and easy tool for tissue extraction. Further studies need to be conducted to evaluate its full potential. © 2015 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Wiley Publishing Asia Pty Ltd.

  3. A new microscope optics for laser dark-field illumination applied to high precision two dimensional measurement of specimen displacement.

    Science.gov (United States)

    Noda, Naoki; Kamimura, Shinji

    2008-02-01

    With conventional light microscopy, precision in the measurement of the displacement of a specimen depends on the signal-to-noise ratio when we measure the light intensity of magnified images. This implies that, for the improvement of precision, getting brighter images and reducing background light noise are both inevitably required. For this purpose, we developed a new optics for laser dark-field illumination. For the microscopy, we used a laser beam and a pair of axicons (conical lenses) to get an optimal condition for dark-field observations. The optics was applied to measuring two dimensional microbead displacements with subnanometer precision. The bandwidth of our detection system overall was 10 kHz. Over most of this bandwidth, the observed noise level was as small as 0.1 nm/radicalHz.

  4. Implantation of 3D-Printed Patient-Specific Aneurysm Models into Cadaveric Specimens: A New Training Paradigm to Allow for Improvements in Cerebrovascular Surgery and Research

    Directory of Open Access Journals (Sweden)

    Arnau Benet

    2015-01-01

    Full Text Available Aim. To evaluate the feasibility of implanting 3D-printed brain aneurysm model in human cadavers and to assess their utility in neurosurgical research, complex case management/planning, and operative training. Methods. Two 3D-printed aneurysm models, basilar apex and middle cerebral artery, were generated and implanted in four cadaveric specimens. The aneurysms were implanted at the same anatomical region as the modeled patient. Pterional and orbitozygomatic approaches were done on each specimen. The aneurysm implant, manipulation capabilities, and surgical clipping were evaluated. Results. The 3D aneurysm models were successfully implanted to the cadaveric specimens’ arterial circulation in all cases. The features of the neck in terms of flexibility and its relationship with other arterial branches allowed for the practice of surgical maneuvering characteristic to aneurysm clipping. Furthermore, the relationship of the aneurysm dome with the surrounding structures allowed for better understanding of the aneurysmal local mass effect. Noticeably, all of these observations were done in a realistic environment provided by our customized embalming model for neurosurgical simulation. Conclusion. 3D aneurysms models implanted in cadaveric specimens may represent an untapped training method for replicating clip technique; for practicing certain approaches to aneurysms specific to a particular patient; and for improving neurosurgical research.

  5. DNA extraction from herbarium specimens.

    Science.gov (United States)

    Drábková, Lenka Záveská

    2014-01-01

    With the expansion of molecular techniques, the historical collections have become widely used. Studying plant DNA using modern molecular techniques such as DNA sequencing plays an important role in understanding evolutionary relationships, identification through DNA barcoding, conservation status, and many other aspects of plant biology. Enormous herbarium collections are an important source of material especially for specimens from areas difficult to access or from taxa that are now extinct. The ability to utilize these specimens greatly enhances the research. However, the process of extracting DNA from herbarium specimens is often fraught with difficulty related to such variables as plant chemistry, drying method of the specimen, and chemical treatment of the specimen. Although many methods have been developed for extraction of DNA from herbarium specimens, the most frequently used are modified CTAB and DNeasy Plant Mini Kit protocols. Nine selected protocols in this chapter have been successfully used for high-quality DNA extraction from different kinds of plant herbarium tissues. These methods differ primarily with respect to their requirements for input material (from algae to vascular plants), type of the plant tissue (leaves with incrustations, sclerenchyma strands, mucilaginous tissues, needles, seeds), and further possible applications (PCR-based methods or microsatellites, AFLP).

  6. A Quantitative Exposure Planning Tool for Surgical Approaches to the Sacroiliac Joint.

    Science.gov (United States)

    Phelps, Kevin D; Ming, Bryan W; Fox, Wade E; Bellamy, Nelly; Sims, Stephen H; Karunakar, Madhav A; Hsu, Joseph R

    2016-06-01

    To aid in surgical planning by quantifying and comparing the osseous exposure between the anterior and posterior approaches to the sacroiliac joint. Anterior and posterior approaches were performed on 12 sacroiliac joints in 6 fresh-frozen torsos. Visual and palpable access to relevant surgical landmarks was recorded. Calibrated digital photographs were taken of each approach and analyzed using Image J. The average surface areas of exposed bone were 44 and 33 cm for the anterior and posterior approaches, respectively. The anterior iliolumbar ligament footprint could be visualized in all anterior approaches, whereas the posterior aspect could be visualized in all but one posterior approach. The anterior approach provided visual and palpable access to the anterior superior edge of the sacroiliac joint in all specimens, the posterior superior edge in 75% of specimens, and the inferior margin in 25% and 50% of specimens, respectively. The inferior sacroiliac joint was easily visualized and palpated in all posterior approaches, although access to the anterior and posterior superior edges was more limited. The anterior S1 neuroforamen was not visualized with either approach and was more consistently palpated when going posterior (33% vs. 92%). Both anterior and posterior approaches can be used for open reduction of pure sacroiliac dislocations, each with specific areas for assessing reduction. In light of current plate dimensions, fractures more than 2.5 cm lateral to the anterior iliolumbar ligament footprint are amenable to anterior plate fixation, whereas those more medial may be better addressed through a posterior approach.

  7. Specimen size effects in Charpy impact testing

    International Nuclear Information System (INIS)

    Alexander, D.J.; Klueh, R.L.

    1989-01-01

    Full-size , half-size, and third-size specimens from several different steels have been tested as part of an ongoing alloy development program. The smaller specimens permit more specimens to be made from small trail heats and are much more efficient for irradiation experiments. The results of several comparisons between the different specimen sizes have shown that the smaller specimens show qualitatively similar behavior to large specimens, although the upper-shelf energy level and ductile-to-ductile transition temperature are reduced. The upper-shelf energy levels from different specimen sizes can be compared by using a simple volume normalization method. The effect of specimen size and geometry on the ductile-to-ductile transition temperature is more difficult to predict, although the available data suggest a simple shift in the transition temperature due to specimen size changes.The relatively shallower notch used in smaller specimens alters the deformation pattern, and permits yielding to spread back to the notched surface as well as through to the back. This reduces the constraint and the peak stresses, and thus the initiation of cleavage is more difficult. A better understanding of the stress and strain distributions is needed. 19 refs., 3 figs., 3 tabs

  8. Methods and devices for small specimen testing at the Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    Jitsukawa, Shiro; Kizaki, Minoru; Umino, Akira; Shiba, Kiyoyuki; Hishinuma, Akimichi

    1993-01-01

    Devices for a punch test on annular notched specimens, small punch (SP) tests, and miniaturized tension tests in hot cells were developed. A micro-manipulator to handle small specimens and an electro-discharge machine (EDM) to extract miniaturized tension specimens and annular notched specimens from transmission electron microscopy (TEM) disks were also fabricated. These devices were designed and made for remote operation in hot cells. Preliminary tests to evaluate the applicability of test methods were carried out. Correlation between SP test results and tensile properties was not strong. Miniaturized tensile results were reasonably similar to the results with larger specimens. The ductile-brittle transition temperature (DBTT) by the punch test on annular notched specimens was higher than that obtained from the SP test. However, materials dependence of the DBTT was different from that measured by standard Charpy V-notch (CVN) tests. This may be due to a specimen size effect

  9. Strip specimen tests for pipeline materials and girth welds

    Energy Technology Data Exchange (ETDEWEB)

    Mohr, William C. [Edison Welding Institute (EWI), Columbus, Ohio (United States)

    2009-07-01

    Strip specimen testing of pipeline materials has been widely applied as a method of getting data relevant to the performance of pipelines under axial direction loading. Comparisons of strip specimen against smaller standard tests (round tensile bar, fracture toughness specimens, polished round bars) and against full-scale or large-scale testing will be explored. Data from early-generation pipe welds from the 1920's to the 1940's to the most recent materials for offshore reeled pipe will be used for examples. Strip samples can provide full thickness information to take account of varying material properties or imperfection distribution through the thickness. Strip samples can also accommodate measurement of effects of the original surface finish or weld surface shape. Strip samples have more design flexibility than standard tests, but must be designed to limit stress concentrations and effects of local bending. (author)

  10. Surgical experts: born or made?

    Science.gov (United States)

    Sadideen, Hazim; Alvand, Abtin; Saadeddin, Munir; Kneebone, Roger

    2013-01-01

    The concept of surgical expertise and the processes involved in its development are topical, and there is a constant drive to identify reliable measures of expert performance in surgery. This review explores the notion of whether surgical experts are "born" or "made", with reference to educational theory and pertinent literature. Peer-reviewed publications, books, and online resources on surgical education, expertise and training were reviewed. Important themes and aspects of expertise acquisition were identified in order to better understand the concept of a surgical expert. The definition of surgical expertise and several important aspects of its development are highlighted. Innate talent plays an important role, but is insufficient on its own to produce a surgical expert. Multiple theories that explore motor skill acquisition and memory are relevant, and Ericsson's theory of the development of competence followed by deliberate self-practice has been especially influential. Psychomotor and non-technical skills are necessary for progression in the current climate in light of our training curricula; surgical experts are adaptive experts who excel in these. The literature suggests that surgical expertise is reached through practice; surgical experts are made, not born. A deeper understanding of the nature of expert performance and its development will ensure that surgical education training programmes are of the highest possible quality. Surgical educators should aim to develop an expertise-based approach, with expert performance as the benchmark. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  11. A comparative study of computed tomography with surgical specimen in 32 cases of hyperparathyroidism

    International Nuclear Information System (INIS)

    Iwamoto, Noriyuki; Yamazaki, Satoru; Hukuda, Toyofumi

    1984-01-01

    We have been localizing pathological parathyroid glands by computed tomography(CT) since December '80. We reviewed 32 cases of surgically-treated hyperparathyroidism, in which 99 parathyroid glands were resected, each weight ranging from 20 to 3300 mg. Comparing the resected parathyroid glands with preoperative CT, we concluded as follows: 1) Pathological parathyroid glands were identified in 25 of the 32 cases (78 %). 2) In parathyroid glands weighing over 300mg, 60 from 64 glands (94 %) were identified by CT. 3) In secondary hyperaparathyroidism with radiologically proven subperiosteal resorption, pathologically-enlarged parathyroid glands were identified by CT in 22 from 23 cases (95%). CT was considered a useful diagnostic method in secondary hyperparathyroidism. 4) Experiencing 2 false-positive cases and one false-negative, which were ectopic cases, we concluded it necesary to use bolus-enhancement in localizing ectopic parathyroid glands. (author)

  12. Current status of prophylactic surgical treatment for familial adenomatous polyposis in Japan.

    Science.gov (United States)

    Yamadera, Masato; Ueno, Hideki; Kobayashi, Hirotoshi; Konishi, Tsuyoshi; Ishida, Fumio; Yamaguchi, Tatsuro; Hinoi, Takao; Inoue, Yasuhiro; Kanemitsu, Yukihide; Tomita, Naohiro; Ishida, Hideyuki; Sugihara, Kenichi

    2017-06-01

    We conducted this study to clarify the current clinical practice of prophylactic colectomy for patients with familial adenomatous polyposis (FAP) in Japan. This retrospective multi-center cohort study involved 23 specialized institutions for colorectal disease in Japan. We analyzed the records of 147 patients who underwent prophylactic surgical treatment between 2000 and 2012. Patients were divided into Group 1 (2000-2006) and Group 2 (2007-2012) based on their date of surgery. Age at the time of prophylactic surgery was 27 and 31 years in Groups 1 and 2, respectively. The proportion of attenuated FAP was significantly lower in Group 2 than in Group 1 (1.0 vs. 13 %, respectively). Pathological examination revealed an increased incidence of malignant polyps in the resected specimens from Group 2 patients (10 vs. 23 %, respectively; P = 0.034). Laparoscopic surgery was more frequent in Group 2 than in Group 1 (61 vs. 40 %, respectively). There was no surgical mortality in either group. Prophylactic surgery for FAP results in good short-term surgical outcomes in Japan. The current surgical approach is characterized by limited surgical indications for patients with attenuated FAP, delayed timing of colectomy, and the increasing standardization of laparoscopic surgery.

  13. Test methodology and technology of fracture toughness for small size specimens

    Energy Technology Data Exchange (ETDEWEB)

    Wakai, E.; Takada, F.; Ishii, T.; Ando, M. [Japan Atomic Energy Agency, Naga-gun, Ibaraki-ken (Japan); Matsukawa, S. [JNE Techno-Research Co., Kanagawa-ken (Japan)

    2007-07-01

    Full text of publication follows: Small specimen test technology (SSTT) is required to investigate mechanical properties in the limited availability of effective irradiation volumes in test reactors and accelerator-based neutron and charged particle sources. The test methodology guideline and the manufacture processes for very small size specimens have not been established, and we would have to formulate it. The technology to control exactly the load and displacement is also required in the test technology under the environment of high dose radiation produced from the specimens. The objective of this study is to examine the test technology and methodology of fracture toughness for very small size specimens. A new bend test machine installed in hot cell has been manufactured to obtain fracture toughness and DBTT (ductile - brittle transition temperature) of reduced-activation ferritic/martensitic steels for small bend specimens of t/2-1/3PCCVN (pre-cracked 1/3 size Charpy V-notch) with 20 mm length and DFMB (deformation and fracture mini bend specimen) with 9 mm length. The new machine can be performed at temperatures from -196 deg. C to 400 deg. C under unloading compliance method. Neutron irradiation was also performed at about 250 deg. C to about 2 dpa in JMTR. After the irradiation, fracture toughness and DBTT were examined by using the machine. Checking of displacement measurement between linear gauge of cross head's displacement and DVRT of the specimen displacement was performed exactly. Conditions of pre-crack due to fatigue in the specimen preparation were also examined and it depended on the shape and size of the specimens. Fracture toughness and DBTT of F82H steel for t/2-1/3PCCVN, DFMB and 0.18DCT specimens before irradiation were examined as a function of temperature. DBTT of smaller size specimens of DFMB was lower than that of larger size specimen of t/2-1/3PCCVN and 0.18DCT. The changes of fracture toughness and DBTT due to irradiation were also

  14. Development of Reconstitution Technology for Surveillance Specimens

    International Nuclear Information System (INIS)

    Yasushi Atago; Shunichi Hatano; Eiichiro Otsuka

    2002-01-01

    The Japan Power Engineering and Inspection Corporation (JAPEIC) has been carrying out the project titled 'Nuclear Power Plant Integrated Management Technology (PLIM)' consigned by Japanese Ministry of Economy, Trade and Industry (METI) since 1996FY as a 10-years project. As one of the project themes, development of reconstitution technology for reactor pressure vessel (RPV/RV) surveillance specimens, which are installed in RPVs to monitor the neutron irradiation embrittlement on RPV/RV materials, is now on being carried out to deal with the long-term operation of nuclear power plants. The target of this theme is to establish the technical standard for applicability of reconstituted surveillance specimens including the reconstitution of the Charpy specimens and Compact Tension (CT) specimens. With the Charpy specimen reconstitution, application of 10 mm length inserts is used, which enables the conversion of tests from the LT-direction to the TL-direction. This paper presents the basic data from Charpy and CT specimens of RPV materials using the surveillance specimens obtained for un-irradiated materials including the following. 1) Reconstitution Technology of Charpy Specimens. a) The interaction between plastic zone and Heat Affected Zone (HAZ). b) The effects of the possible deviations from the standard specimens for the reconstituted specimens. 2) Reconstitution Technology of CT specimens. a) The correlation between fracture toughness and plastic zone width. Because the project is now in progress, this paper describes the outline of the results obtained as of the end of 2000 FY. (authors)

  15. Prospective Study of the Surgical Techniques Used in Primary Rhinoplasty on the Caucasian Nose and Comparison of the Preoperative and Postoperative Anthropometric Nose Measurements

    Science.gov (United States)

    Berger, Cezar Augusto Sarraf; Freitas, Renato da Silva; Malafaia, Osvaldo; Pinto, José Simão de Paula; Macedo Filho, Evaldo Dacheux; Mocellin, Marcos; Fagundes, Marina Serrato Coelho

    2014-01-01

    Introduction The knowledge and study of surgical techniques and anthropometric measurements of the nose make possible a qualitative and quantitative analysis of surgical results. Objective Study the main technique used in rhinoplasty on Caucasian noses and compare preoperative and postoperative anthropometric measurements of the nose. Methods A prospective study with 170 patients was performed at a private hospital. Data were collected using the Electronic System Integrated of Protocols software (Sistema Integrado de Protocolos Eletrônicos, SINPE©). The surgical techniques used in the nasal dorsum and tip were evaluated. Preoperative and 12-month follow-up photos as well as the measurements compared with the ideal aesthetic standard of a Caucasian nose were analyzed objectively. Student t test and standard deviation test were applied. Results There was a predominance of endonasal access (94.4%). The most common dorsum technique was hump removal (33.33%), and the predominance of sutures (24.76%) was observed on the nasal tip, with the lateral intercrural the most frequent (32.39%). Comparison between preoperative and postoperative photos found statistically significant alterations on the anthropometric measurements of the noses. Conclusion The main surgical techniques on Caucasian noses were evaluated, and a great variety was found. The evaluation of anthropometric measurements of the nose proved the efficiency of the performed procedures. PMID:25992149

  16. Quantitative X-ray microanalysis of biological specimens

    International Nuclear Information System (INIS)

    Roomans, G.M.

    1988-01-01

    Qualitative X-ray microanalysis of biological specimens requires an approach that is somewhat different from that used in the materials sciences. The first step is deconvolution and background subtraction on the obtained spectrum. The further treatment depends on the type of specimen: thin, thick, or semithick. For thin sections, the continuum method of quantitation is most often used, but it should be combined with an accurate correction for extraneous background. However, alternative methods to determine local mass should also be considered. In the analysis of biological bulk specimens, the ZAF-correction method appears to be less useful, primarily because of the uneven surface of biological specimens. The peak-to-local background model may be a more adequate method for thick specimens that are not mounted on a thick substrate. Quantitative X-ray microanalysis of biological specimens generally requires the use of standards that preferably should resemble the specimen in chemical and physical properties. Special problems in biological microanalysis include low count rates, specimen instability and mass loss, extraneous contributions to the spectrum, and preparative artifacts affecting quantitation. A relatively recent development in X-ray microanalysis of biological specimens is the quantitative determination of local water content

  17. Radical prostatectomy: positive surgical margins matter.

    Science.gov (United States)

    Meeks, Joshua J; Eastham, James A

    2013-10-01

    A positive surgical margin (PSM) in the radical prostatectomy (RP) specimen is associated with biochemical recurrence (BCR) and the need for adjuvant radiation therapy, and is a surrogate for surgical quality. We review the available data describing the identification, anatomy, and management of PSM after RP. A PubMed search (using English language as a filter) was performed to identify factors affecting PSMs and their management. PSMs are associated with an increased likelihood of BCR after RP. The most common location for a PSM is the apex, followed by the posterolateral edge of the prostate. The risk of recurrence in a patient with a PSM is associated with the location, length, and Gleason score of the PSM. The management of a patient with a PSM remains controversial, with some recommending adjuvant radiation therapy for all PSMs and others suggesting only salvage radiation therapy for men who experience BCR. PSMs are associated with an increased likelihood of BCR and often result in initiation of adjuvant treatment. Therefore, the goal of surgery should be to minimize the likelihood of a PSM. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Sequence Capture and Phylogenetic Utility of Genomic Ultraconserved Elements Obtained from Pinned Insect Specimens.

    Directory of Open Access Journals (Sweden)

    Bonnie B Blaimer

    Full Text Available Obtaining sequence data from historical museum specimens has been a growing research interest, invigorated by next-generation sequencing methods that allow inputs of highly degraded DNA. We applied a target enrichment and next-generation sequencing protocol to generate ultraconserved elements (UCEs from 51 large carpenter bee specimens (genus Xylocopa, representing 25 species with specimen ages ranging from 2-121 years. We measured the correlation between specimen age and DNA yield (pre- and post-library preparation DNA concentration and several UCE sequence capture statistics (raw read count, UCE reads on target, UCE mean contig length and UCE locus count with linear regression models. We performed piecewise regression to test for specific breakpoints in the relationship of specimen age and DNA yield and sequence capture variables. Additionally, we compared UCE data from newer and older specimens of the same species and reconstructed their phylogeny in order to confirm the validity of our data. We recovered 6-972 UCE loci from samples with pre-library DNA concentrations ranging from 0.06-9.8 ng/μL. All investigated DNA yield and sequence capture variables were significantly but only moderately negatively correlated with specimen age. Specimens of age 20 years or less had significantly higher pre- and post-library concentrations, UCE contig lengths, and locus counts compared to specimens older than 20 years. We found breakpoints in our data indicating a decrease of the initial detrimental effect of specimen age on pre- and post-library DNA concentration and UCE contig length starting around 21-39 years after preservation. Our phylogenetic results confirmed the integrity of our data, giving preliminary insights into relationships within Xylocopa. We consider the effect of additional factors not measured in this study on our age-related sequence capture results, such as DNA fragmentation and preservation method, and discuss the promise of the UCE

  19. Neutron diffraction measurements for the determination of residual stresses in MMC tensile and fatigue specimens

    DEFF Research Database (Denmark)

    Fiori, F.; Girardin, E.; Giuliani, A.

    2000-01-01

    have been performed at RISO (Roskilde, DK) and HMI-BENSC (Berlin, D), for the determination of residual stress in AA2124 + 17% SiCp and AA359 + 20% SiCp specimens, submitted to tensile and fatigue tests. For each of the investigated samples, the macrostress has been separated from the elastic......, residual stresses are present in both the matrix and the particles microstructure, prior to any macroscopic loading. They vary with the temperature and with the type and level of loading imposed to the material, having a strong influence on the mechanical behaviour of MMCs. Neutron diffraction measurements...... and thermal mismatch microstresses. The results show that, in general, the main contribution to the stress state of both matrix and reinforcement is given by the thermal microstresses, already existing due to heat treatment prior to mechanical tests. (C) 2000 Elsevier Science B.V. All rights reserved....

  20. Activity-based differentiation of pathologists' workload in surgical pathology.

    Science.gov (United States)

    Meijer, G A; Oudejans, J J; Koevoets, J J M; Meijer, C J L M

    2009-06-01

    Adequate budget control in pathology practice requires accurate allocation of resources. Any changes in types and numbers of specimens handled or protocols used will directly affect the pathologists' workload and consequently the allocation of resources. The aim of the present study was to develop a model for measuring the pathologists' workload that can take into account the changes mentioned above. The diagnostic process was analyzed and broken up into separate activities. The time needed to perform these activities was measured. Based on linear regression analysis, for each activity, the time needed was calculated as a function of the number of slides or blocks involved. The total pathologists' time required for a range of specimens was calculated based on standard protocols and validated by comparing to actually measured workload. Cutting up, microscopic procedures and dictating turned out to be highly correlated to number of blocks and/or slides per specimen. Calculated workload per type of specimen was significantly correlated to the actually measured workload. Modeling pathologists' workload based on formulas that calculate workload per type of specimen as a function of the number of blocks and slides provides a basis for a comprehensive, yet flexible, activity-based costing system for pathology.

  1. Failure mechanism of resistance-spot-welded specimens impacted on base material by bullets

    Science.gov (United States)

    Fan, Chunlei; Ma, Bohan; Chen, Danian; Wang, Huanran; Ma, Dongfang

    2018-01-01

    The tests of bullet impact on the base material (BM) of a simple specimen with a single resistance-spot-welded (RSW) nugget of TRIP800 steel are performed to investigate the response of the RSW specimen to the ballistic debris impact on the RSW specimen. A one-stage gas gun is used to fire the bullets while a laser velocity interferometer system for any reflector (VISAR) is used to measure the velocity histories of the free surfaces of the RSW specimen. The recovered RSW specimens are examined with the three-dimensional super depth digital microscope (SDDM) and the scanning electro microscope (SEM). For the tests of small multiple-bullet impact, it is revealed that the wave train of the VISAR measured results and the detachment of the base material interfaces in the recovered RSW specimens are directly related to the reflection and refraction of the curved stress waves incoming to the interfaces and the free surfaces in the RSW specimens. The detachment of BM interfaces can lead to the impact failure of the RSW joints for the larger multiple-bullet impact at higher velocity, the mechanism of which is different from the case for normal incidence (spalling). For the tests of single large bullet impact, it is brought to light experimentally that the plastic strain concentration at the "notch tip" spurs either the crack near the RSW joint or the split of the nugget. The numerical simulation shows up the process of splitting the nugget: a crack initiates at the "notch tip", propagates across the nugget interface and splits the nugget into two parts. It is indicated that the interaction between the stress waves and many interfaces/free surfaces in the RSW specimen under ballistic impact causes variable local stress triaxialities and stress Lode angles, which affects the deformation and fracture mechanism of the RSW specimen including stretching and shearing failure. It is shown that the impact failure of the RSW joints is a mixture of brittle fracture and ductile

  2. Controlled Environment Specimen Transfer

    DEFF Research Database (Denmark)

    Damsgaard, Christian Danvad; Zandbergen, Henny W.; Hansen, Thomas Willum

    2014-01-01

    an environmental transmission electron microscope to an in situ X-ray diffractometer through a dedicated transmission electron microscope specimen transfer holder, capable of sealing the specimen in a gaseous environment at elevated temperatures. Two catalyst material systems have been investigated; Cu/ZnO/Al2O3...... transferred in a reactive environment to the environmental transmission electron microscope where further analysis on the local scale were conducted. The Co/Al2O3 catalyst was reduced in the environmental microscope and successfully kept reduced outside the microscope in a reactive environment. The in situ......Specimen transfer under controlled environment conditions, such as temperature, pressure, and gas composition, is necessary to conduct successive complementary in situ characterization of materials sensitive to ambient conditions. The in situ transfer concept is introduced by linking...

  3. Multimodal strategies to improve surgical outcome

    DEFF Research Database (Denmark)

    Kehlet, Henrik; Wilmore, Douglas W

    2002-01-01

    OBJECTIVE: To evaluate the effect of modifying perioperative care in noncardiac surgical patients on morbidity, mortality, and other outcome measures. BACKGROUND: New approaches in pain control, introduction of techniques that reduce the perioperative stress response, and the more frequent use...... anesthesia in elective operations, and pilot studies of fast track surgical procedures using the multimodality approach. RESULTS: The introduction of newer approaches to perioperative care has reduced both morbidity and mortality in surgical patients. In the future, most elective operations will become day...... surgical procedures or require only 1 to 2 days of postoperative hospitalization. Reorganization of the perioperative team (anesthesiologists, surgeons, nurses, and physical therapists) will be essential to achieve successful fast track surgical programs. CONCLUSIONS: Understanding perioperative...

  4. Estimation of Surface Temperature and Heat Flux by Inverse Heat Transfer Methods Using Internal Temperatures Measured While Radiantly Heating a Carbon/Carbon Specimen up to 1920 F

    Science.gov (United States)

    Pizzo, Michelle; Daryabeigi, Kamran; Glass, David

    2015-01-01

    The ability to solve the heat conduction equation is needed when designing materials to be used on vehicles exposed to extremely high temperatures; e.g. vehicles used for atmospheric entry or hypersonic flight. When using test and flight data, computational methods such as finite difference schemes may be used to solve for both the direct heat conduction problem, i.e., solving between internal temperature measurements, and the inverse heat conduction problem, i.e., using the direct solution to march forward in space to the surface of the material to estimate both surface temperature and heat flux. The completed research first discusses the methods used in developing a computational code to solve both the direct and inverse heat transfer problems using one dimensional, centered, implicit finite volume schemes and one dimensional, centered, explicit space marching techniques. The developed code assumed the boundary conditions to be specified time varying temperatures and also considered temperature dependent thermal properties. The completed research then discusses the results of analyzing temperature data measured while radiantly heating a carbon/carbon specimen up to 1920 F. The temperature was measured using thermocouple (TC) plugs (small carbon/carbon material specimens) with four embedded TC plugs inserted into the larger carbon/carbon specimen. The purpose of analyzing the test data was to estimate the surface heat flux and temperature values from the internal temperature measurements using direct and inverse heat transfer methods, thus aiding in the thermal and structural design and analysis of high temperature vehicles.

  5. Full thickness crack arrest investigations on compact specimens and a heavy wide-plate

    International Nuclear Information System (INIS)

    Kussmaul, K.; Gillot, R.; Elenz, T.

    1993-01-01

    In order to determine the influence of specimen size and testing procedure on the crack arrest toughness K Ia at various temperatures, investigations were carried out on a wide-plate and compact specimens using a highly brittle material. Test interpretation included static as well as dynamic methods. The comparison of the measured K Ia -values shows good agreement although there is a distinct difference in specimen size. In general, the (static) ASTM test method yields a lower and thus conservative estimate of the crack arrest toughness K Ia . 14 refs., 27 figs., 3 tabs

  6. Thermal endurance tests on silicone rubber specimens

    International Nuclear Information System (INIS)

    Warburton, C.

    1977-07-01

    Thermal endurance tests have been performed on a range of silicone rubber specimens at temperature above 300 0 C. It is suggested that the rubber mix A2426, the compound from which Wylfa sealing rings are manufactured, will fail at temperatures above 300 0 C within weeks. Hardness measurements show that this particular rubber performs in a similar manner to Walker's S.I.L./60. (author)

  7. Bacterial migration through punctured surgical gloves under real surgical conditions

    Directory of Open Access Journals (Sweden)

    Heidecke Claus-Dieter

    2010-07-01

    Full Text Available Abstract Background The aim of this study was to confirm recent results from a previous study focussing on the development of a method to measure the bacterial translocation through puncture holes in surgical gloves under real surgical conditions. Methods An established method was applied to detect bacterial migration from the operating site through the punctured glove. Biogel™ double-gloving surgical gloves were used during visceral surgeries over a 6-month period. A modified Gaschen-bag method was used to retrieve organisms from the inner glove, and thus-obtained bacteria were compared with micro-organisms detected by an intra-operative swab. Results In 20 consecutive procedures, 194 gloves (98 outer gloves, 96 inner gloves were examined. The rate of micro-perforations of the outer surgical glove was 10% with a median wearing time of 100 minutes (range: 20-175 minutes. Perforations occurred in 81% on the non-dominant hand, with the index finger most frequently (25% punctured. In six cases, bacterial migration could be demonstrated microbiologically. In 5% (5/98 of outer gloves and in 1% (1/96 of the inner gloves, bacterial migration through micro-perforations was observed. For gloves with detected micro-perforations (n = 10 outer layers, the calculated migration was 50% (n = 5. The minimum wearing time was 62 minutes, with a calculated median wearing time of 71 minutes. Conclusions This study confirms previous results that bacterial migration through unnoticed micro-perforations in surgical gloves does occur under real practical surgical conditions. Undetected perforation of surgical gloves occurs frequently. Bacterial migration from the patient through micro-perforations on the hand of surgeons was confirmed, limiting the protective barrier function of gloves if worn over longer periods.

  8. Analysis of C-shaped canal systems in mandibular second molars using surgical operating microscope and cone beam computed tomography: A clinical approach.

    Science.gov (United States)

    Chhabra, Sanjay; Yadav, Seema; Talwar, Sangeeta

    2014-05-01

    The study was aimed to acquire better understanding of C-shaped canal systems in mandibular second molar teeth through a clinical approach using sophisticated techniques such as surgical operating microscope and cone beam computed tomography (CBCT). A total of 42 extracted mandibular second molar teeth with fused roots and longitudinal grooves were collected randomly from native Indian population. Pulp chamber floors of all specimens were examined under surgical operating microscope and classified into four types (Min's method). Subsequently, samples were subjected to CBCT scan after insertion of K-files size #10 or 15 into each canal orifice and evaluated using the cross-sectional and 3-dimensional images in consultation with dental radiologist so as to obtain more accurate results. Minimum distance between the external root surface on the groove and initial file placed in the canal was also measured at different levels and statistically analyzed. Out of 42 teeth, maximum number of samples (15) belonged to Type-II category. A total of 100 files were inserted in 86 orifices of various types of specimens. Evaluation of the CBCT scan images of the teeth revealed that a total of 21 canals were missing completely or partially at different levels. The mean values for the minimum thickness were highest at coronal followed by middle and apical third levels in all the categories. Lowest values were obtained for teeth with Type-III category at all three levels. The present study revealed anatomical variations of C-shaped canal system in mandibular second molars. The prognosis of such complex canal anatomies can be improved by simultaneous employment of modern techniques such as surgical operating microscope and CBCT.

  9. Changes in measured size of atherosclerotic plaque calcifications in dual-energy CT of ex vivo carotid endarterectomy specimens: effect of monochromatic keV image reconstructions

    International Nuclear Information System (INIS)

    Mannelli, Lorenzo; Mitsumori, Lee M.; Ferguson, Marina; Xu, Dongxiang; Chu, Baocheng; Branch, Kelley R.; Shuman, William P.; Yuan, Chun

    2013-01-01

    The aim of this study was to compare the size of the calcifications measured on the different keV images to a histological standard. Five ex vivo carotid endarterectomy (CEA) specimens were imaged with a dual-energy CT. CT images were reconstructed at different monochromatic spectral energies (40, 60, 77, 80, 100, 120, 140 keV). Cross-sectional area of the plaque calcifications present on each CT image was measured. The histological calcium areas on each corresponding CEA specimen were traced manually on digitised images of Toluidine Blue/Basic Fuchsin stained plastic sections. The CT images and corresponding histology sections were matched. The CT-derived calcium areas on each keV image were compared to the calcified area measurements by histology. A total of 107 histology sections were matched to corresponding CT images. The average calcified area per section by histology was 7.6 ± 7 mm 2 (range 0-26.4 mm 2 ). There was no significant difference between the calcified areas measured by histology and those measured on CT-virtual monochromatic spectral (VMS) reconstructed images at 77 keV (P = 0.08), 80 keV (P = 0.20) and 100 keV (P = 0.14). Calcium area measured on the 80 keV image set was most comparable to the amount of calcium measured by histology. (orig.)

  10. First report on joint use of a Da Vinci® surgical system with transfer of surgical know-how between two public hospitals.

    Science.gov (United States)

    Mattei, Agostino; Thoms, Michael; Ferrari, Matteo; La Croce, Giovanni; Danuser, Hansjörg; Schmid, Hans-Peter; Engeler, Daniel

    2014-01-01

    The costs of a Da Vinci® device for robot- assisted surgery, in particular for robot-assisted radical prostatectomy (RARP), can be a considerable issue for hospitals with limited caseloads. Since January 2011 the cantonal hospitals of Lucerne and St. Gallen (Switzerland) have shared a four-arm Da Vinci® device, transferring the surgical know-how by a Lucerne teaching surgeon to a St. Gallen surgeon. Complete pre- and perioperative data, including 3-month surgical RARP outcomes, were prospectively documented. For statistical analysis, Wilcoxon, exact Poisson and χ(2) tests were used. During the first year, the two hospitals (61 RARP patients in Lucerne, 19 RARP patients in St. Gallen) did not differ significantly in preoperative, perioperative or oncological and functional results except for prostate volume (median 33 [interquartile range 24-40] vs. 40 [interquartile range 33-57] ml; p = 0.02), operation time (mean 252 ± 49 vs. 351 ± 50 min; p = 0.0001), number of lymph nodes removed (median 16 [interquartile range 13-21] vs. 15 [interquartile range 8-16] nodes; p = 0.02), biopsy (p = 0.04) and specimen Gleason scores (p = 0.03), and length of hospital stay (median 8 [interquartile range 7-14] vs. 9 [interquartile range 8-18] days; p < 0.01). Da Vinci® device sharing with transfer of surgical know-how can reduce the costs of RARP without compromising surgical outcomes, even at the beginning of the learning curve. © 2014 S. Karger AG, Basel.

  11. Bacteriological aspects implicated in abdominal surgical emergencies.

    Science.gov (United States)

    Israil, A M; Delcaru, C; Palade, R S; Chifiriuc, C; Iordache, C; Vasile, D; Grigoriu, M; Voiculescu, D

    2010-01-01

    The purpose of the present study was to establish the microbial etiology of abdominal surgical emergencies as well as the relationship between the bacterial etiology and the virulence factors produced by the respective isolated strains. 110 bacterial strains were isolated from 100 randomized clinical cases, operated during 2009-2010 in the First Surgical Clinic of the University Hospital of Bucharest. The clinical cases (sex ratio 52 M/48F aged between 22-85 years old) were classified into three risk groups, as related to their severity. The isolated strains were characterized by cultural, microscopic and biochemical methods. After identification, the bacterial strains were investigated for their virulence potential (adherence to abiotic surface and production of soluble virulence factors). The specimens were collected from different clinical pathologies: diffuse acute peritonitis, biliary duct infections, severe acute pancreatitis followed by septic processes etc. The 110 bacterial (72 aerobic and 38 anaerobic) strains were isolated only in 70 out of 100 cases. Out of these 70 cases, in 45 already submitted to pre-operatory empiric broad spectrum antibiotic therapy, there were isolated 74 strains, whereas in 25 cases without any treatment, there were isolated 36 strains. The etiology was either mono-specific or multi-specific (aerobic-anaerobic associations, especially in old persons). Out of the 30 negative culture cases, 16 were already submitted to pre-operatory parenteral empiric antibiotic therapy at the moment of specimen collection. The aerobic etiology was dominated by Enterobacteriaceae. The most frequent anaerobic species belonged to Clostridium, Peptococcus and Bacteroides genera. It is to be mentioned that the isolation of Bifidobacterium and Veillonella spp. in 11 (10%) severe cases of the studied abdominal surgical emergencies is pleading for the fact that in certain conditions, bacteria belonging usually to commensal gut flora can turn to pathogenic

  12. Mesh-morphing algorithms for specimen-specific finite element modeling.

    Science.gov (United States)

    Sigal, Ian A; Hardisty, Michael R; Whyne, Cari M

    2008-01-01

    Despite recent advances in software for meshing specimen-specific geometries, considerable effort is still often required to produce and analyze specimen-specific models suitable for biomechanical analysis through finite element modeling. We hypothesize that it is possible to obtain accurate models by adapting a pre-existing geometry to represent a target specimen using morphing techniques. Here we present two algorithms for morphing, automated wrapping (AW) and manual landmarks (ML), and demonstrate their use to prepare specimen-specific models of caudal rat vertebrae. We evaluate the algorithms by measuring the distance between target and morphed geometries and by comparing response to axial loading simulated with finite element (FE) methods. First a traditional reconstruction process based on microCT was used to obtain two natural specimen-specific FE models. Next, the two morphing algorithms were used to compute mappings from the surface of one model, the source, to the other, the target, and to use this mapping to morph the source mesh to produce a target mesh. The microCT images were then used to assign element-specific material properties. In AW the mappings were obtained by wrapping the source and target surfaces with an auxiliary triangulated surface. In ML, landmarks were manually placed on corresponding locations on the surfaces of both source and target. Both morphing algorithms were successful in reproducing the shape of the target vertebra with a median distance between natural and morphed models of 18.8 and 32.2 microm, respectively, for AW and ML. Whereas AW-morphing produced a surface more closely resembling that of the target, ML guaranteed correspondence of the landmark locations between source and target. Morphing preserved the quality of the mesh producing models suitable for FE simulation. Moreover, there were only minor differences between natural and morphed models in predictions of deformation, strain and stress. We therefore conclude that

  13. Surgical site infections

    African Journals Online (AJOL)

    Decrease the inflammatory response Vasodilatation leads to better perfusion and ... Must NOT be allowed to come in contact with brain, meninges, eyes or .... project (SCIP): Evolution of National Quality Measure. Surgical. Infection 2008 ...

  14. Surgical site infections due to rapidly growing mycobacteria in puducherry, India.

    Science.gov (United States)

    Kannaiyan, Kavitha; Ragunathan, Latha; Sakthivel, Sulochana; Sasidar, A R; Muralidaran; Venkatachalam, G K

    2015-03-01

    Rapidly growing Mycobacteria are increasingly recognized, nowadays as an important pathogen that can cause wide range of clinical syndromes in humans. We herein describe unrelated cases of surgical site infection caused by Rapidly growing Mycobacteria (RGM), seen during a period of 12 months. Nineteen patients underwent operations by different surgical teams located in diverse sections of Tamil Nadu, Pondicherry, Karnataka, India. All patients presented with painful, draining subcutaneous nodules at the infection sites. Purulent material specimens were sent to the microbiology laboratory. Gram stain and Ziehl-Neelsen staining methods were used for direct examination. Culture media included blood agar, chocolate agar, MacConkey agar, Sabourauds agar and Lowenstein-Jensen medium for Mycobacteria. Isolated microorganisms were identified and further tested for antimicrobial susceptibility by standard microbiologic procedures. Mycobacterium fortuitum and M.chelonae were isolated from the purulent drainage obtained from wounds by routine microbiological techniques from all the specimens. All isolates analyzed for antimicrobial susceptibility pattern were sensitive to clarithromycin, linezolid and amikacin but were variable to ciprofloxacin, rifampicin and tobramycin. Our case series highlights that a high level of clinical suspicion should be maintained for patients presenting with protracted soft tissue lesions with a history of trauma or surgery as these infections not only cause physical but also emotional distress that affects both the patients and the surgeon.

  15. Evaluation of DC electric field distribution of PPLP specimen based on the measurement of electrical conductivity in LN2

    Science.gov (United States)

    Hwang, Jae-Sang; Seong, Jae-Kyu; Shin, Woo-Ju; Lee, Jong-Geon; Cho, Jeon-Wook; Ryoo, Hee-Suk; Lee, Bang-Wook

    2013-11-01

    High temperature superconducting (HTS) cable has been paid much attention due to its high efficiency and high current transportation capability, and it is also regarded as eco-friendly power cable for the next generation. Especially for DC HTS cable, it has more sustainable and stable properties compared to AC HTS cable due to the absence of AC loss in DC HTS cable. Recently, DC HTS cable has been investigated competitively all over the world, and one of the key components of DC HTS cable to be developed is a cable joint box considering HVDC environment. In order to achieve the optimum insulation design of the joint box, analysis of DC electric field distribution of the joint box is a fundamental process to develop DC HTS cable. Generally, AC electric field distribution depends on relative permittivity of dielectric materials but in case of DC, electrical conductivity of dielectric material is a dominant factor which determines electric field distribution. In this study, in order to evaluate DC electric field characteristics of the joint box for DC HTS cable, polypropylene laminated paper (PPLP) specimen has been prepared and its DC electric field distribution was analyzed based on the measurement of electrical conductivity of PPLP in liquid nitrogen (LN2). Electrical conductivity of PPLP in LN2 has not been reported yet but it should be measured for DC electric field analysis. The experimental works for measuring electrical conductivity of PPLP in LN2 were presented in this paper. Based on the experimental works, DC electric field distribution of PPLP specimen was fully analyzed considering the steady state and the transient state of DC. Consequently, it was possible to determine the electric field distribution characteristics considering different DC applying stages including DC switching on, DC switching off and polarity reversal conditions.

  16. Use of Performance Measures to Evaluate, Document Competence and Deterioration of Advanced Surgical Skills Exposure for Trauma (ASSET) Surgical Skills

    Science.gov (United States)

    2015-03-01

    Sharon Henry1, Stacy Shackelford4. 1Shock Trauma Anesthesiology Research, University of Maryland Baltimore; 2The Alfred Hospital and Swinburne...Bethesda USA, The Alfred Hospital and Swinburne University, Melbourne, Australia • 6) THE ASSETS OF ASSET: IMPROVING SURGICAL PERFROMANCE...ACTIVITY 820 CHANDLER STREET FORT DETRICK MD 21702-5014 January 15, 2015 SUBJECT: BA 150077- "Refreshing Combat Surgical Skills for Vascular Control

  17. Development of fatigue life evaluation method using small specimen

    International Nuclear Information System (INIS)

    Nogami, Shuhei; Nishimura, Arata; Wakai, Eichi; Tanigawa, Hiroyasu; Itoh, Takamoto; Hasegawa, Akira

    2013-01-01

    For developing the fatigue life evaluation method using small specimen, the effect of specimen size and shape on the fatigue life of the reduced activation ferritic/martensitic steels (F82H-IEA, F82H-BA07 and JLF-1) was investigated by the fatigue test at room temperature in air using round-bar and hourglass specimens with various specimen sizes (test section diameter: 0.85–10 mm). The round-bar specimen showed no specimen size and no specimen shape effects on the fatigue life, whereas the hourglass specimen showed no specimen size effect and obvious specimen shape effect on it. The shorter fatigue life of the hourglass specimen observed under low strain ranges could be attributed to the shorter micro-crack initiation life induced by the stress concentration dependent on the specimen shape. On the basis of this study, the small round-bar specimen was an acceptable candidate for evaluating the fatigue life using small specimen

  18. Prospective Study of the Surgical Techniques Used in Primary Rhinoplasty on the Caucasian Nose and Comparison of the Preoperative and Postoperative Anthropometric Nose Measurements

    Directory of Open Access Journals (Sweden)

    Berger, Cezar Augusto Sarraf

    2014-12-01

    Full Text Available Introduction The knowledge and study of surgical techniques and anthropometric measurements of the nose make possible a qualitative and quantitative analysis of surgical results. Objective Study the main technique used in rhinoplasty on Caucasian noses and compare preoperative and postoperative anthropometric measurements of the nose. Methods A prospective study with 170 patients was performed at a private hospital. Data were collected using the Electronic System Integrated of Protocols software (Sistema Integrado de Protocolos Eletrônicos, SINPE©. The surgical techniques used in the nasal dorsum and tip were evaluated. Preoperative and 12-month follow-up photos as well as the measurements compared with the ideal aesthetic standard of a Caucasian nose were analyzed objectively. Student t test and standard deviation test were applied. Results There was a predominance of endonasal access (94.4%. The most common dorsum technique was hump removal (33.33%, and the predominance of sutures (24.76% was observed on the nasal tip, with the lateral intercrural the most frequent (32.39%. Comparison between preoperative and postoperative photos found statistically significant alterations on the anthropometric measurements of the noses. Conclusion The main surgical techniques on Caucasian noses were evaluated, and a great variety was found. The evaluation of anthropometric measurements of the nose proved the efficiency of the performed procedures.

  19. Specimen holder for an electron microscope and device and method for mounting a specimen in an electron microscope

    NARCIS (Netherlands)

    Zandbergen, H.W.; Latenstein van Voorst, A.; Westra, C.; Hoveling, G.H.

    1996-01-01

    A specimen holder for an electron microscope, comprising a bar-shaped body provided adjacent one end with means for receiving a specimen, with means being present for screening the specimen from the environment at least temporarily in airtight and moisture-proof manner in a first position, which

  20. A general mixed mode fracture mechanics test specimen: The DCB-specimen loaded with uneven bending moments

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, B.F.; Joergensen, K.; Oestergaard, R.C. [Risoe National Lab., Materials Dept., Roskilde (Denmark); Jacobsen, T.K. [LM Glasfiber A/S, Lunderskov (Denmark)

    2004-03-01

    A mixed mode specimen is proposed for fracture mechanics characterisation of adhesive joints, laminates and multilayers. The specimen is a double cantilever beam specimen loaded with uneven bending moments at the two free beams. By varying the ratio between the two applied moments, the full mode mixity range from pure mode I to pure mode II can be generated for the same specimen geometry. The specimen allows stable crack growth. In case of large scale crack bridging, mixed mode cohesive laws can be obtained by a J integral based approach. As a preliminary example, fracture of adhesive joints between two glass-fibre laminates was studied. The mixed mode fracture resistance increased with increasing crack length due to fibre cross over bridging, eventually reaching a steady-state level (R-curve behaviour). The steady-state fracture toughness level increased with increasing tangential crack opening displacement. Cohesive stresses were determined by a J integral approach. The deducted shear stress was found to be relative high ({approx} = 20 MPa) in comparison with the normal stress ({approx} = 1 MPa). (au)

  1. Enhanced radiometric detection of Mycobacterium paratuberculosis by using filter-concentrated bovine fecal specimens

    International Nuclear Information System (INIS)

    Collins, M.T.; Kenefick, K.B.; Sockett, D.C.; Lambrecht, R.S.; McDonald, J.; Jorgensen, J.B.

    1990-01-01

    A commercial radiometric medium, BACTEC 12B, was modified by addition of mycobactin, egg yolk suspension, and antibiotics (vancomycin, amphotericin B, and nalidixic acid). Decontaminated bovine fecal specimens were filter concentrated by using 3-microns-pore-size, 13-mm-diameter polycarbonate filters, and the entire filter was placed into the radiometric broth. Comparison of the radiometric technique with conventional methods on 603 cattle from 9 Mycobacterium paratuberculosis-infected herds found that of 75 positive specimens, the radiometric technique detected 92% while conventional methods detected 60% (P less than 0.0005). Only 3.9% of radiometric cultures were contaminated. To measure the effect of filter concentration of specimens on the detection rate, 5 cattle with minimal and 5 with moderate ileum histopathology were sampled weekly for 3 weeks. M. paratuberculosis was detected in 33.3% of nonfiltered specimens and 76.7% of filtered specimens (P less than 0.005). Detection rates were directly correlated with the severity of disease, and the advantage of specimen concentration was greatest on fecal specimens from cattle with low-grade infections. Detection times were also correlated with infection severity: 13.4 +/- 5.9 days with smear-positive specimens, 27.9 +/- 8.7 days with feces from cows with typical subclinical infections, and 38.7 +/- 3.8 days with fecal specimens from cows with low-grade infections. Use of a cocktail of vancomycin, amphotericin B, and nalidixic acid for selective suppression of nonmycobacterial contaminants was better than the commercial product PANTA (Becton Dickinson Microbiologic Systems, Towson, Md.) only when specimens contained very low numbers of M. paratuberculosis

  2. [Specificity of the anaerobic bacterial infections in the surgical and orthopedic wards].

    Science.gov (United States)

    Kierzkowska, Marta; Majewska, Anna; Sawicka-Grzelak, Anna; Młynarczyk, Andrzej; Ładomirska-Pestkowska, Katarzvna; Młynarczyk, Grazyna

    2012-01-01

    The aim of this study was to estimate the contribution strictly anaerobic bacteria in the etiology of infections in patients on surgery and orthopedic wards. We examined 159 samples taken from patients hospitalized in surgical wards and 179 clinical specimens taken from orthopedic patients. Clinical strains of obligate anaerobes were identified by API 20A biochemical tests (ATB Expression, bioMerieux S.A., France). Susceptibility of the clinical strains was examined by ATB ANA (bioMerieux S.A., France) system. The MIC values were determined by the gradient diffusion method, Etest (AB BIODISK, Sweden i bioMerieux S.A., France). Gram-negative bacteria predominant in the samples taken from surgical patients, Most frequently we isolated rods of the genus Bacteroides (26%): B. fragilis, B. ovatus/B. thetaiotaomicron, and B. distasonis. In 44 samples (28%) we identified only anaerobic bacteria. Multibacterial isolations, with the participation of anaerobic and aerobic flora, dominated among patients in the study. Overall 238 strictly anaerobic bacteria were cultured from patients hospitalized in orthopedic wards. Gram-positive bacteria accounted for 78%. The most frequently were isolated Peptostreptococcus (56%), Propionibacterium (10%) species. In this study all Bacteroides strains were resistant to penicillin G. Some species were resistant to clindamycin, as well. Overall 40% of Bacteroides strains taken from surgical and 50% isolated from orthopedic wards showed no sensitivity to this antibiotic. A similar phenomenon was observed among bacteria of the genus Prevotella. In samples taken from orthopedic patients we observed the predominance of Gram-positive anaerobic bacteria. Some of them were part of the normal flora but they should not be excluded as an etiology agents of infection. The specimens taken from patients treated in surgical wards showed the presence of a mixed microflora, which included aerobic and anaerobic bacteria, primarily Gram-negative rods

  3. Elastic scattering spectroscopy findings in formalin-fixed oral squamous cell carcinoma specimens

    Science.gov (United States)

    Swinson, B.; Elmaaytah, M.; Jerjes, W.; Hopper, C.

    2005-11-01

    Oral squamous cell carcinoma (OSCC) has been shown to spread locally and infiltrate adjacent bone or via the lymphatic system to the cervical lymph nodes. This usually necessitates a surgical neck dissection and either a local or segmental resection for bone clearance. While histopathology remains the gold standard for tissue diagnosis, several new diagnostic techniques are being developed that rely on physical and biochemical changes that mirror or precede malignant changes within tissue. The aim of this study was to compare findings of Elastic Scattering Spectroscopy (ESS) with histopathology on formalin-fixed specimens of both neck lymph node dissections and de-calcified archival bone from patients with OSCC. We wished to see if this technique could be used as an adjunct or alternative to histopathology in defining cervical nodal involvement and if it could be used to identify bone resection margins positive for tumour. 130 lymph nodes were examined from 13 patients. The nodes were formalin-fixed, bivalved and examined by ESS. The intensity of the spectrum at 4 points was considered for comparison; at 360nm, 450nm, 630nm and 690nm. 341 spectra were taken from the mandibular specimens of 21 patients, of which 231 spectra were taken from histologically positive sites and the rest were normal. The nodes and bone specimens were then routinely processed with haematoxylin and eosin-stained sections, examined histopathologically, and the results compared. Using Linear Discriminant Analysis (LDA) as a statistical method, a sensitivity of 98% and a specificity of 68% was obtained for the neck nodes and a sensitivity of 87% and a specificity of 80% for the bone margins.

  4. A Novel Piezo-Actuator-Sensor Micromachine for Mechanical Characterization of Micro-Specimens

    Directory of Open Access Journals (Sweden)

    Leila Ladani

    2010-12-01

    Full Text Available Difficulties associated with testing and characterization of materials at microscale demands for new technologies and devices that are capable of measuring forces and strains at microscale. To address this issue, a novel electroactive-based micro-electro-mechanical machine is designed. The micromachine is comprised of two electroactive (piezoelectric micro-elements mounted on a rigid frame. Electrical activation of one of the elements causes it to expand and induce a stress in the intervening micro-specimen. The response of the microspecimen to the stress is measured by the deformation and thereby voltage/resistance induced in the second electro-active element. The concept is theoretically proven using analytical modeling in conjunction with non-linear, three dimensional finite element analyses for the micromachine. Correlation of the output voltage to the specimen stiffness is shown. It is also demonstrated through finite element and analytical analysis that this technique is capable of detecting non-linear behavior of materials. A characteristic curve for an isotropic specimen exhibiting linear elastic behavior is developed. Application of the proposed device in measuring coefficient of thermal expansion is explored and analytical analysis is conducted.

  5. Patient satisfaction and quality of surgical care in US hospitals.

    Science.gov (United States)

    Tsai, Thomas C; Orav, E John; Jha, Ashish K

    2015-01-01

    The relationship between patient satisfaction and surgical quality is unclear for US hospitals. Using national data, we examined if hospitals with high patient satisfaction have lower levels of performance on accepted measures of the quality and efficiency of surgical care. Federal policymakers have made patient satisfaction a core measure for the way hospitals are evaluated and paid through the value-based purchasing program. There is broad concern that performance on patient satisfaction may have little or even a negative correlation with the quality of surgical care, leading to potential trade-offs in efforts to improve patient experience with other surgical quality measures. We used the Hospital Consumer Assessment of Healthcare Providers and Systems survey data from 2010 and 2011 to assess performance on patient experience. We used national Medicare data on 6 common surgical procedures to calculate measures of surgical efficiency and quality: risk-adjusted length of stay, process score, risk-adjusted mortality rate, risk-adjusted readmission rate, and a composite z score across all 4 metrics. Multivariate models adjusting for hospital characteristics were used to assess the independent relationships between patient satisfaction and measures of surgical efficiency and quality. Of the 2953 US hospitals that perform one of these 6 procedures, the median patient satisfaction score was 69.5% (interquartile range, 63%-75.5%). Length of stay was shorter in hospitals with the highest levels of patient satisfaction (7.1 days vs 7.7 days, P patient satisfaction had the higher process of care performance (96.5 vs 95.5, P patient satisfaction also had a higher composite score for quality across all measures (P patient satisfaction provided more efficient care and were associated with higher surgical quality. Our findings suggest there need not be a trade-off between good quality of care for surgical patients and ensuring a positive patient experience.

  6. Quantifying surgical access in eyebrow craniotomy with and without orbital bar removal: cadaver and surgical phantom studies.

    Science.gov (United States)

    Zador, Zsolt; Coope, David J; Gnanalingham, Kanna; Lawton, Michael T

    2014-04-01

    Eyebrow craniotomy is a recently described minimally invasive approach for tackling primarily pathology of the anterior skull base. The removal of the orbital bar may further expand the surgical corridor of this exposure, but the extent of benefit is poorly quantified. We assessed the effect of orbital bar removal with regards to surgical access in the eyebrow craniotomy using classic morphometric measurements in cadaver heads. Using surgical phantoms and neuronavigation, we also measured the 'working volume', a new parameter for characterising the volume of surgical access in these approaches. Silicon injected cadaver heads (n = 5) were used for morphometric analysis of the eyebrow craniotomy with and without orbital bar removal. Working depths and 'working areas' of surgical access were measured as defined by key anatomical landmarks. The eyebrow craniotomy with or without orbital bar removal was also simulated using surgical phantoms (n = 3, 90-120 points per trial), calibrated against a frameless neuronavigation system. Working volume was derived from reference coordinates recorded along the anatomical borders of the eyebrow craniotomy using the "α-shape algorithm" in R statistics. In cadaver heads, eyebrow craniotomy with removal of the orbital bar reduced the working depth to the ipsilateral anterior clinoid process (42 ± 2 versus 33 ± 3 mm; p < 0.05), but the working areas as defined by deep neurovascular and bony landmarks was statistically unchanged (total working areas of 418 ± 80 cm(2) versus 334 ± 48 cm(2); p = 0.4). In surgical phantom studies, however, working-volume for the simulated eyebrow craniotomies was increased with orbital bar removal (16 ± 1 cm(3) versus 21 ± 1 cm(3); p < 0.01). In laboratory studies, orbital bar removal in eyebrow craniotomy provides a modest reduction in working depth and increase in the working volume. But this must be weighed up against the added morbidity of the

  7. A curved beam test specimen for determining the interlaminar tensile strength of a laminated composite

    Science.gov (United States)

    Hiel, Clement C.; Sumich, Mark; Chappell, David P.

    1991-01-01

    A curved beam type of test specimen is evaluated for use in determining the through-the-thickness strength of laminated composites. Two variations of a curved beam specimen configuration (semicircular and elliptical) were tested to failure using static and fatigue loads. The static failure load for the semicircular specimens was found to be highly sensitive to flaw content, with the specimens falling into two distinct groups. This result supports the use of proof testing for structural validation. Static design allowables are derived based on the Weibull distribution. Fatigue data indicates no measured increase in specimen compliance prior to final fracture. All static and fatigue failures at room temperature dry conditions occurred catastrophically. The elliptical specimens demonstrated unusually high failure strengths indicating the presence of phenomena requiring further study. Results are also included for specimens exposed to a wet environment showing a matrix strength degradation due to moisture content. Further testing is underway to evaluate a fatigue methodology for matrix dominated failures based on residual static strength (wearout).

  8. In-line phase contrast micro-CT reconstruction for biomedical specimens.

    Science.gov (United States)

    Fu, Jian; Tan, Renbo

    2014-01-01

    X-ray phase contrast micro computed tomography (micro-CT) can non-destructively provide the internal structure information of soft tissues and low atomic number materials. It has become an invaluable analysis tool for biomedical specimens. Here an in-line phase contrast micro-CT reconstruction technique is reported, which consists of a projection extraction method and the conventional filter back-projection (FBP) reconstruction algorithm. The projection extraction is implemented by applying the Fourier transform to the forward projections of in-line phase contrast micro-CT. This work comprises a numerical study of the method and its experimental verification using a biomedical specimen dataset measured at an X-ray tube source micro-CT setup. The numerical and experimental results demonstrate that the presented technique can improve the imaging contrast of biomedical specimens. It will be of interest for a wide range of in-line phase contrast micro-CT applications in medicine and biology.

  9. Clinical and histologic evaluation of non-surgical periodontal therapy with enamel matrix derivative: a report of four cases.

    Science.gov (United States)

    Mellonig, James T; Valderrama, Pilar; Gregory, Holly J; Cochran, David L

    2009-09-01

    Enamel matrix derivative (EMD) is a composite of proteins that was demonstrated histologically to work as an adjunct to periodontal regenerative surgical therapy. The purpose of this study was to evaluate the clinical and histologic effects of EMD as an adjunct to scaling and root planing. Four patients with severe chronic periodontitis and scheduled to receive complete dentures were accrued. Probing depth and clinical attachment levels were obtained. Unlimited time was allowed for hand and ultrasonic instrumentation. A notch was placed in the root >or=1 to 2 mm from the apical extent of root planing. EMD was inserted into the pocket, and a periodontal dressing was placed. Patients were seen every 2 weeks for plaque control. At 6 months post-treatment, soft tissue measurements were repeated, and the teeth were removed en bloc and prepared for histomorphologic analysis. Probing depth reduction and clinical attachment level gain were obtained in three-fourths of the specimens. Three of the four specimens analyzed histologically demonstrated new cementum, bone, periodontal ligament, and connective tissue attachment coronal to the notch. In one specimen, the gingival margin had receded below the notch. The results were unexpected and may represent an aberration. However, the substantial reduction in deep probing depths and clinical attachment level gain in three of four specimens, in addition to the histologic findings of new cementum, new bone, a new periodontal ligament, and a new connective tissue attachment, suggest that EMD may be useful as an adjunct to scaling and root planing in single-rooted teeth.

  10. Evaluation of DC electric field distribution of PPLP specimen based on the measurement of electrical conductivity in LN2

    International Nuclear Information System (INIS)

    Hwang, Jae-Sang; Seong, Jae-Kyu; Shin, Woo-Ju; Lee, Jong-Geon; Cho, Jeon-Wook; Ryoo, Hee-Suk; Lee, Bang-Wook

    2013-01-01

    Highlights: •The electrical conductivity of PPLP in LN 2 was successfully measured. •Based on the measured value of PPLP, DC field analysis was performed. •The electric field distribution was altered according to the DC applying stages. •The maximum electric field was observed during polarity reversal situation. •DC field analysis is important to determine the optimum design of DC HTS devices. -- Abstract: High temperature superconducting (HTS) cable has been paid much attention due to its high efficiency and high current transportation capability, and it is also regarded as eco-friendly power cable for the next generation. Especially for DC HTS cable, it has more sustainable and stable properties compared to AC HTS cable due to the absence of AC loss in DC HTS cable. Recently, DC HTS cable has been investigated competitively all over the world, and one of the key components of DC HTS cable to be developed is a cable joint box considering HVDC environment. In order to achieve the optimum insulation design of the joint box, analysis of DC electric field distribution of the joint box is a fundamental process to develop DC HTS cable. Generally, AC electric field distribution depends on relative permittivity of dielectric materials but in case of DC, electrical conductivity of dielectric material is a dominant factor which determines electric field distribution. In this study, in order to evaluate DC electric field characteristics of the joint box for DC HTS cable, polypropylene laminated paper (PPLP) specimen has been prepared and its DC electric field distribution was analyzed based on the measurement of electrical conductivity of PPLP in liquid nitrogen (LN 2 ). Electrical conductivity of PPLP in LN 2 has not been reported yet but it should be measured for DC electric field analysis. The experimental works for measuring electrical conductivity of PPLP in LN 2 were presented in this paper. Based on the experimental works, DC electric field distribution of

  11. Effect of surgical skill on surgically-induced astigmatism in cataract surgery

    Directory of Open Access Journals (Sweden)

    Numan Eraslan

    2015-12-01

    Full Text Available AIM:To evaluate the effect of surgical experience on surgically-induced astigmatism(SIAin patients with uncomplicated phacoemulsification surgery.METHODS:Fifty-three eyes of fifty patients, mean age 64.5±10.8y, were randomly divided into two groups(23 eyes and 30 eyes. First group was underwent surgery by cataract specialists and the second was by residents. At baseline all the patients were underwent a complete opthalmological examination including keratometry and autorefractometer measurements. Vector analysis programme including the Alpins' method was used for the calculation of SIA. All the measurements were repeated postoperative first day, first month and second month and changes were recorded. Shapiro Wilk and Mann-Whitney tests were applied for determining the statistical differences between the SIA with two groups.RESULTS:There were no significant differences in demographic data of the groups. Intergroup analysis showed, first group was more effective results in SIA postoperative first day(P=0.002, first month(P=0.004and the second month(P=0.001. For the first group, SIA were 0.79±0.41 diopter(Dat the first postoperative day, 0.54±0.41 D at the first postoperative month and 0.47±0.37 D at the second postoperative month. Second one was 1.27±0.66 D, 0.98±0.56 D and 0.94±0.54 D, respectively.CONCLUSION:According to the results, surgical experience was one of the factors that affects SIA. Residents would perform more phacoemilcification surgery to obtain more surgical experience.

  12. A general mixed mode fracture mechanics test specimen: The DCB-specimen loaded with uneven bending moments

    DEFF Research Database (Denmark)

    Sørensen, Bent F.; Jørgensen, K.; Jacobsen, T.K.

    2004-01-01

    A mixed mode specimen is proposed for fracture mechanics characterisation of adhesive joints, laminates and multilayers. The specimen is a double cantilever beam specimen loaded with uneven bending moments at the two free beams. By varying the ratiobetween the two applied moments, the full mode...... glass-fibre laminates was studied. The mixed mode fracture resistance increased with increasing crack length due to fibre bridging, eventually reaching asteady-state level (R-curve behaviour). The steady-state fracture toughness level increased with increasing tangential crack opening displacement....

  13. Failure mechanism of resistance-spot-welded specimens impacted on base material by bullets

    Directory of Open Access Journals (Sweden)

    Chunlei Fan

    2018-01-01

    Full Text Available The tests of bullet impact on the base material (BM of a simple specimen with a single resistance-spot-welded (RSW nugget of TRIP800 steel are performed to investigate the response of the RSW specimen to the ballistic debris impact on the RSW specimen. A one-stage gas gun is used to fire the bullets while a laser velocity interferometer system for any reflector (VISAR is used to measure the velocity histories of the free surfaces of the RSW specimen. The recovered RSW specimens are examined with the three-dimensional super depth digital microscope (SDDM and the scanning electro microscope (SEM. For the tests of small multiple-bullet impact, it is revealed that the wave train of the VISAR measured results and the detachment of the base material interfaces in the recovered RSW specimens are directly related to the reflection and refraction of the curved stress waves incoming to the interfaces and the free surfaces in the RSW specimens. The detachment of BM interfaces can lead to the impact failure of the RSW joints for the larger multiple-bullet impact at higher velocity, the mechanism of which is different from the case for normal incidence (spalling. For the tests of single large bullet impact, it is brought to light experimentally that the plastic strain concentration at the “notch tip” spurs either the crack near the RSW joint or the split of the nugget. The numerical simulation shows up the process of splitting the nugget: a crack initiates at the “notch tip”, propagates across the nugget interface and splits the nugget into two parts. It is indicated that the interaction between the stress waves and many interfaces/free surfaces in the RSW specimen under ballistic impact causes variable local stress triaxialities and stress Lode angles, which affects the deformation and fracture mechanism of the RSW specimen including stretching and shearing failure. It is shown that the impact failure of the RSW joints is a mixture of brittle

  14. Surgical management of colonic diverticular disease: discrepancy between right- and left-sided diseases.

    Science.gov (United States)

    Oh, Heung-Kwon; Han, Eon Chul; Ha, Heon-Kyun; Choe, Eun Kyung; Moon, Sang Hui; Ryoo, Seung-Bum; Jeong, Seung-Yong; Park, Kyu Joo

    2014-08-07

    To compare the outcome of the surgical management of left-sided and right-sided diverticular disease. The medical records of 77 patients who were surgically treated for diverticular disease between 1999 and 2010 in a tertiary referral hospital were retrospectively reviewed. The study population was limited to cases wherein the surgical specimen was confirmed as diverticulosis by pathology. Right-sided diverticula were classified as those arising from the cecum, ascending colon, and transverse colon, and those from the descending colon, sigmoid colon, and rectum were classified as left-sided diverticulosis. To assess the changing trend of occurrence of diverticulosis, data were compared with two previous studies of 51 patients. The proportion of left-sided disease cases was significantly increased compared to the results of our previous studies in 1994 and 2001, (27.5% vs 48.1%, P disease. However, patients with right-sided disease were significantly younger (50.9 year vs 64.0 year, P disease was significantly associated with a higher incidence of complicated diverticulitis (89.2% vs 57.5%, P diverticular disease, the incidence of left-sided disease in Korea has increased since 2001 and is associated with worse surgical outcomes.

  15. Recent advances in FIB-TEM specimen preparation techniques

    International Nuclear Information System (INIS)

    Li Jian; Malis, T.; Dionne, S.

    2006-01-01

    Preparing high-quality transmission electron microscopy (TEM) specimens is of paramount importance in TEM studies. The development of the focused ion beam (FIB) microscope has greatly enhanced TEM specimen preparation capabilities. In recent years, various FIB-TEM foil preparation techniques have been developed. However, the currently available techniques fail to produce TEM specimens from fragile and ultra-fine specimens such as fine fibers. In this paper, the conventional FIB-TEM specimen preparation techniques are reviewed, and their advantages and shortcomings are compared. In addition, a new technique suitable to prepare TEM samples from ultra-fine specimens is demonstrated

  16. Reliability of 46,XX results on miscarriage specimens: a review of 1,222 first-trimester miscarriage specimens.

    Science.gov (United States)

    Lathi, Ruth B; Gustin, Stephanie L F; Keller, Jennifer; Maisenbacher, Melissa K; Sigurjonsson, Styrmir; Tao, Rosina; Demko, Zach

    2014-01-01

    To examine the rate of maternal contamination in miscarriage specimens. Retrospective review of 1,222 miscarriage specimens submitted for chromosome testing with detection of maternal cell contamination (MCC). Referral centers requesting genetic testing of miscarriage specimens at a single reference laboratory. Women with pregnancy loss who desire complete chromosome analysis of the pregnancy tissue. Analysis of miscarriage specimens using single-nucleotide polymorphism (SNP) microarray technology with bioinformatics program to detect maternal cell contamination. Chromosome content of miscarriages and incidence of 46,XX results due to MCC. Of the 1,222 samples analyzed, 592 had numeric chromosomal abnormalities, and 630 were normal 46,XX or 46,XY (456 and 187, respectively). In 269 of the 46,XX specimens, MCC with no embryonic component was found. With the exclusion of maternal 46,XX results, the chromosomal abnormality rate increased from 48% to 62%, and the ratio for XX to XY results dropped from 2.6 to 1.0. Over half of the normal 46,XX results in miscarriage specimens were due to MCC. The use of SNPs in MCC testing allows for precise identification of chromosomal abnormalities in miscarriage as well as MCC, improving the accuracy of products of conception testing. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  17. The response of pressure vessel steel specimens on drop weight loading

    International Nuclear Information System (INIS)

    Winkler, S.; Kalthoff, J.F.; Gerscha, A.

    1979-01-01

    Load records obtained in instrumented impact tests in general are disturbed by inertia effects. The influence of mechanical damping provisions on these disturbing inertia effects is investigated. Precracked bend specimens are dynamically loaded in a drop weight testing system. The specimens of size 620 mm x 150 mm (25 mm or 50 mm thick) were machined from the pressure vessel steel 22 NiMoCr 37 which was heat treated to achieve a specially hardened condition. The tests were performed at two different low temperatures. The impact velocity was about 4 m/s. As it is usual in instrumented impact testing, the load at the tup of the impining striker is recorded as a function of time during the impact process. In addition the specimen is instrumented by a strain gage close to the crack tip in order to directly measure the stress intensification. Experiments were performed under pure and damped impact conditions. Damping was achieved by utilizing a soft aluminum plate between the striker and the specimen. (orig.)

  18. Deginerative changes of femoral articular cartilage in the knee : comparative study of specimen sonography and pathology

    International Nuclear Information System (INIS)

    Park, Ju Youn; Hong, Sung Hwan; Sohn, Jin Hee; Wee, Young Hoon; Chang, Jun Dong; Park, Hong Seok; Lee, Eil Seoung; Kang Ik Won

    2001-01-01

    To determine the sonographic findings of degenerative change in femoral articular cartilage of the knee by comparative study of specimen sonography and pathology. We obtained 40 specimens of cartilage of the femur (20 medial and 20 lateral condylar) from 20 patients with osteoarthritis of the knee who had undergone total knee replacement. The specimens were placed in a saline-filled container and sonography was performed using a 10-MHz linear transducer. Sonographic abnormalities were evaluated at the cartilage surface, within the cartilage, and at the bone-cartilage interface, and were compared with the corresponding pathologic findings. In addition, cartilage thickness was measured at a representative portion of each femoral cartilage specimen and was compared with the thickness determined by sonography. 'Dot' lesions, irregularity or loss of the hyperechoic line, were demonstrated by sonography at the saline-cartilage interface of 14 cartilages. Pathologic examination showed that these findings corresponded to cleft, detachment, erosion, and degeneration. Irregularities in the hyperechoic line at the bone-cartilage interface were revealed by sonography in eight cartilages and were related to irregularity or loss of tidemark, downward displacement of the cartilage, and subchondral callus formation. Dot lesions, corresponding to cleft and degeneration, were noted within one cartilage. Cartilage thickness measured on specimen and by sonography showed no significant difference (p=0.446). Specimen sonography suggested that articular cartilage underwent degenerative histopathological change. Cartilage thickness measured by sonography exactly reflected real thickness

  19. Development of fatigue life evaluation technique using miniature specimen

    International Nuclear Information System (INIS)

    Nogami, Shuhei; Nishimura, Arata; Fujiwara, Masaharu; Hisaka, Tomoaki

    2012-01-01

    To develop the fatigue life evaluation technique using miniature specimen, the investigation of the effect of specimen size and specimen shape on the fatigue life and the development of the fatigue testing machine, especially the extensometer, were carried out. The effect of specimen size on the fatigue life was almost negligible for the round-bar specimens. The shorter fatigue life at relatively low strain range conditions for the hourglass specimen that the standard specimen were observed. Therefore the miniature round-bar specimen was considered to be adequate for the fatigue life evaluation using small specimen. Several types of the extensometer system using a strain gauge and a laser has been developed for realizing the fatigue test of the miniature round-bar specimen at high temperature in vacuum. (author)

  20. Numerical study and pilot evaluation of experimental data measured on specimen loaded by bending and wedge splitting forces

    Directory of Open Access Journals (Sweden)

    S. Seitl

    2017-01-01

    Full Text Available The fracture mechanical properties of silicate based materials are determined from various fracture mechanicals tests, e.g. three- or four- point bending test, wedge splitting test, modified compact tension test etc. For evaluation of the parameters, knowledge about the calibration and compliance functions is required. Therefore, in this paper, the compliance and calibration curves for a novel test geometry based on combination of the wedge splitting test and three-point bending test are introduced. These selected variants exhibit significantly various stress state conditions at the crack tip, or, more generally, in the whole specimen ligament. The calibration and compliance curves are compared and used for evaluation of the data from pilot experimental measurement.

  1. Definitions and general remarks on surgical pathology in the field of oncology

    International Nuclear Information System (INIS)

    Arnould, L.

    2001-01-01

    In the field of oncology, surgical pathology analysis of biopsies or surgical specimens directly determines the care program of each patient. Without going into too much detail, we report here the description of different characteristics of neoplastic lesions, necessary or useful for the establishment of the care program of the patients. These macroscopic and microscopic analyses should result in the most precise possible diagnosis and should take into account a list of other factors which allow the development of an optimal strategy for therapy, and the establishment of prognosis of the tumor. These characteristics include properties of the tumor such as the size, shape, exact location, and the grade of the lesion, etc. They also concern the relationship of the tumor to certain structures like the basal membranes, the stroma reaction, the lymphatic vessels, the nerves, and so forth. The description of local and locoregional spreading, as well as the analysis of the surgical margins gives essential information as well. Finally, in certain cases, the description of modifications induced by neo-adjuvant therapy allows the evaluation of the treatment's efficacy. (author)

  2. TEM specimen preparation of semiconductor-PMMA-metal interfaces

    International Nuclear Information System (INIS)

    Thangadurai, P.; Lumelsky, Yulia; Silverstein, Michael S.; Kaplan, Wayne D.

    2008-01-01

    Transmission electron microscopy (TEM) cross-section specimens of PMMA in contact with gold and Si were prepared by focused ion beam (FIB) and compared with plan-view PMMA specimens prepared by a dip-coating technique. The specimens were characterized by TEM and electron energy loss spectroscopy (EELS). In the cross-section specimens, the thin films of PMMA were located in a Si-PMMA-Au multilayer. Different thicknesses of PMMA films were spin-coated on the Si substrates. The thickness of the TEM specimens prepared by FIB was estimated using EELS to be 0.65 of the plasmon mean-free-path. Along the PMMA-Au interface, Au particle diffusion into the PMMA was observed, and the size of the Au particles was in the range of 2-4 nm. Dip-coating of PMMA directly on Cu TEM grids resulted in thin specimens with a granular morphology, with a thickness of 0.58 of the plasmon mean-free-path. The dip-coated specimens were free from ion milling induced artifacts, and thus serve as control specimens for comparison with the cross-sectioned specimens prepared by FIB

  3. Comparison of gross anatomy test scores using traditional specimens vs. QuickTime Virtual Reality animated specimens

    Science.gov (United States)

    Maza, Paul Sadiri

    In recent years, technological advances such as computers have been employed in teaching gross anatomy at all levels of education, even in professional schools such as medical and veterinary medical colleges. Benefits of computer based instructional tools for gross anatomy include the convenience of not having to physically view or dissect a cadaver. Anatomy educators debate over the advantages versus the disadvantages of computer based resources for gross anatomy instruction. Many studies, case reports, and editorials argue for the increased use of computer based anatomy educational tools, while others discuss the necessity of dissection for various reasons important in learning anatomy, such as a three-dimensional physical view of the specimen, physical handling of tissues, interactions with fellow students during dissection, and differences between specific specimens. While many articles deal with gross anatomy education using computers, there seems to be a lack of studies investigating the use of computer based resources as an assessment tool for gross anatomy, specifically using the Apple application QuickTime Virtual Reality (QTVR). This study investigated the use of QTVR movie modules to assess if using computer based QTVR movie module assessments were equal in quality to actual physical specimen examinations. A gross anatomy course in the College of Veterinary Medicine at Cornell University was used as a source of anatomy students and gross anatomy examinations. Two groups were compared, one group taking gross anatomy examinations in a traditional manner, by viewing actual physical specimens and answering questions based on those specimens. The other group took the same examinations using the same specimens, but the specimens were viewed as simulated three-dimensional objects in a QTVR movie module. Sample group means for the assessments were compared. A survey was also administered asking students' perceptions of quality and user-friendliness of the QTVR

  4. Evaluation of irradiated coating material specimens

    International Nuclear Information System (INIS)

    Lee, Yong Jin; Nam, Seok Woo; Cho, Lee Moon

    2007-12-01

    Evaluation result of irradiated coating material specimens - Coating material specimens radiated Gamma Energy(Co 60) in air condition. - Evaluation conditions was above 1 X 10 4 Gy/hr, and radiated TID 2.0 X 10 6 Gy. - The radiated coating material specimens, No Checking, Cracking, Flaking, Delamination, Peeling and Blistering. - Coating system at the Kori no. 1 and APR 1400 Nuclear power plant, evaluation of irradiated coating materials is in accordance with owner's requirement(2.0 X 10 6 Gy)

  5. Virtual reality in surgical education.

    Science.gov (United States)

    Ota, D; Loftin, B; Saito, T; Lea, R; Keller, J

    1995-03-01

    Virtual reality (VR) is an emerging technology that can teach surgeons new procedures and can determine their level of competence before they operate on patients. Also VR allows the trainee to return to the same procedure or task several times later as a refresher course. Laparoscopic surgery is a new operative technique which requires the surgeon to observe the operation on a video-monitor and requires the acquisition of new skills. VR simulation could duplicate the operative field and thereby enhance training and reduce the need for expensive animal training models. Our preliminary experience has shown that we have the technology to model tissues and laparoscopic instruments and to develop in real time a VR learning environment for surgeons. Another basic need is to measure competence. Surgical training is an apprenticeship requiring close supervision and 5-7 years of training. Technical competence is judged by the mentor and has always been subjective. If VR surgical simulators are to play an important role in the future, quantitative measurement of competence would have to be part of the system. Because surgical competence is "vague" and is characterized by such terms as "too long, too short" or "too close, too far," it is possible that the principles of fuzzy logic could be used to measure competence in a VR surgical simulator. Because a surgical procedure consists of a series of tasks and each task is a series of steps, we will plan to create two important tasks in a VR simulator and validate their use. These tasks consist of laparoscopic knot tying and laparoscopic suturing. Our hypothesis is that VR in combination with fuzzy logic can educate surgeons and determine when they are competent to perform these procedures on patients.

  6. Standardised metrics for global surgical surveillance.

    Science.gov (United States)

    Weiser, Thomas G; Makary, Martin A; Haynes, Alex B; Dziekan, Gerald; Berry, William R; Gawande, Atul A

    2009-09-26

    Public health surveillance relies on standardised metrics to evaluate disease burden and health system performance. Such metrics have not been developed for surgical services despite increasing volume, substantial cost, and high rates of death and disability associated with surgery. The Safe Surgery Saves Lives initiative of WHO's Patient Safety Programme has developed standardised public health metrics for surgical care that are applicable worldwide. We assembled an international panel of experts to develop and define metrics for measuring the magnitude and effect of surgical care in a population, while taking into account economic feasibility and practicability. This panel recommended six measures for assessing surgical services at a national level: number of operating rooms, number of operations, number of accredited surgeons, number of accredited anaesthesia professionals, day-of-surgery death ratio, and postoperative in-hospital death ratio. We assessed the feasibility of gathering such statistics at eight diverse hospitals in eight countries and incorporated them into the WHO Guidelines for Safe Surgery, in which methods for data collection, analysis, and reporting are outlined.

  7. Analysis of stress intensity factors for a new mechanical corrosion specimen

    International Nuclear Information System (INIS)

    Rassineux, B.; Crouzet, D.; Le Hong, S.

    1996-03-01

    Electricite de France is conducting a research program to determine corrosion cracking rates in the steam generators Alloy 600 tubes of the primary system. The objective is to correlate the cracking rates with the specimen stress intensity factor K I . One of the samples selected for the purpose of this study is the longitudinal notched specimen TEL (TEL: ''Tubulaire a Entailles Longitudinales''). This paper presents the analysis of the stress intensity factor and its experimental validation. The stress intensity factor has been evaluated for different loads using 3D finite element calculations with the Hellen-Parks and G(θ) methods. Both crack initiation and propagation are considered. As an assessment of the method, the numerical simulations are in good agreement with the fatigue crack growth rates measured experimentally for TEL and compact tension (CT) specimens. (authors). 8 refs., 6 figs., 2 tabs

  8. Design of measurement system for Doppler broadening profiles of annihilation radiations as a function of controlled specimen temperature and its applications for a study of metals in the thermal equilibrium state

    International Nuclear Information System (INIS)

    Uedono, Akira; Tanigawa, Shoichiro; Kawano, Takao.

    1992-01-01

    The measurement system for Doppler broadening profiles of annihilation radiation was developed. This system reads out data for energies of γ-rays from an analog to digital converter and those for specimen temperature from a digital-voltmeter coupled to a thermocouple. These two types of digital-quantities were stored in a memory matrix of 512 channels (energy) x 128 channels (temperature) x 4 byte (count). For this purpose, a memory board of 256 kbyte with 32-dynamic RAMs (64 kbits) was used. The data acquisition was controlled by a microcomputer. Temperature of the specimen was controlled by a programmable temperature controller, thus it can be varied in a desired way. This was useful for measurements in repeated temperature cycles. A sample heater with a compact size was developed in order to obtain a homogeneous temperature distribution in the specimen. Application of this system for a study of thermal vacancies in Al-dilute alloys was also shown. (author)

  9. Retrospective analysis of heavy metal contamination in Rhode Island based on old and new herbarium specimens.

    Science.gov (United States)

    Rudin, Sofia M; Murray, David W; Whitfeld, Timothy J S

    2017-01-01

    Herbarium specimens may provide a record of past environmental conditions, including heavy metal pollution. To explore this potential, we compared concentrations of copper, lead, and zinc in historical and new collections from four sites in Rhode Island, USA. We compared historical specimens (1846 to 1916) to congener specimens collected in 2015 at three former industrial sites in Providence, Rhode Island, and one nonindustrial site on Block Island. Leaf material was prepared by UltraWAVE SRC Microwave Digestion, and heavy metal concentrations were measured by inductively coupled plasma-atomic emission spectroscopy. Heavy metal concentrations in the historical and new specimens were measurable for all elements tested, and levels of copper and zinc were comparable in the historical and 2015 collections. By contrast, the concentration of lead declined at all sites over time. Significant variability in heavy metal concentration was observed between taxa, reflecting their varied potential for elemental accumulation. It seems clear that herbarium specimens can be used to evaluate past levels of pollution and assess local environmental changes. With careful sampling effort, these specimens can be a valuable part of environmental science research. Broadening the possible applications for herbarium collections in this way increases their relevance in an era of reduced funding for collections-based research.

  10. Notch effects in uniaxial tension specimens

    International Nuclear Information System (INIS)

    Delph, T.J.

    1979-03-01

    Results of a literature survey on the effect of notches on the time-dependent failure of uniaxial tension specimens at elevated temperatures are presented. Particular attention is paid to the failure of notched specimens containing weldments

  11. Tumor Size on Abdominal MRI Versus Pathologic Specimen in Resected Pancreatic Adenocarcinoma: Implications for Radiation Treatment Planning

    Energy Technology Data Exchange (ETDEWEB)

    Hall, William A., E-mail: whall4@emory.edu [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Mikell, John L. [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Mittal, Pardeep [Department of Radiology, Emory University, Atlanta, Georgia (United States); Colbert, Lauren [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Prabhu, Roshan S. [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Kooby, David A. [Department of Surgery, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Nickleach, Dana [Biostatistics and Bioinformatics Shared Resource, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States); Hanley, Krisztina [Department of Pathology, Emory University, Atlanta, Georgia (United States); Sarmiento, Juan M. [Department of Surgery, Emory University, Atlanta, Georgia (United States); Ali, Arif N.; Landry, Jerome C. [Department of Radiation Oncology, Emory University, Atlanta, Georgia (United States); Winship Cancer Institute, Emory University, Atlanta, Georgia (United States)

    2013-05-01

    Purpose: We assessed the accuracy of abdominal magnetic resonance imaging (MRI) for determining tumor size by comparing the preoperative contrast-enhanced T1-weighted gradient echo (3-dimensional [3D] volumetric interpolated breath-hold [VIBE]) MRI tumor size with pathologic specimen size. Methods and Materials: The records of 92 patients who had both preoperative contrast-enhanced 3D VIBE MRI images and detailed pathologic specimen measurements were available for review. Primary tumor size from the MRI was independently measured by a single diagnostic radiologist (P.M.) who was blinded to the pathology reports. Pathologic tumor measurements from gross specimens were obtained from the pathology reports. The maximum dimensions of tumor measured in any plane on the MRI and the gross specimen were compared. The median difference between the pathology sample and the MRI measurements was calculated. A paired t test was conducted to test for differences between the MRI and pathology measurements. The Pearson correlation coefficient was used to measure the association of disparity between the MRI and pathology sizes with the pathology size. Disparities relative to pathology size were also examined and tested for significance using a 1-sample t test. Results: The median patient age was 64.5 years. The primary site was pancreatic head in 81 patients, body in 4, and tail in 7. Three patients were American Joint Commission on Cancer stage IA, 7 stage IB, 21 stage IIA, 58 stage IIB, and 3 stage III. The 3D VIBE MRI underestimated tumor size by a median difference of 4 mm (range, −34-22 mm). The median largest tumor dimensions on MRI and pathology specimen were 2.65 cm (range, 1.5-9.5 cm) and 3.2 cm (range, 1.3-10 cm), respectively. Conclusions: Contrast-enhanced 3D VIBE MRI underestimates tumor size by 4 mm when compared with pathologic specimen. Advanced abdominal MRI sequences warrant further investigation for radiation therapy planning in pancreatic adenocarcinoma before

  12. Tumor Size on Abdominal MRI Versus Pathologic Specimen in Resected Pancreatic Adenocarcinoma: Implications for Radiation Treatment Planning

    International Nuclear Information System (INIS)

    Hall, William A.; Mikell, John L.; Mittal, Pardeep; Colbert, Lauren; Prabhu, Roshan S.; Kooby, David A.; Nickleach, Dana; Hanley, Krisztina; Sarmiento, Juan M.; Ali, Arif N.; Landry, Jerome C.

    2013-01-01

    Purpose: We assessed the accuracy of abdominal magnetic resonance imaging (MRI) for determining tumor size by comparing the preoperative contrast-enhanced T1-weighted gradient echo (3-dimensional [3D] volumetric interpolated breath-hold [VIBE]) MRI tumor size with pathologic specimen size. Methods and Materials: The records of 92 patients who had both preoperative contrast-enhanced 3D VIBE MRI images and detailed pathologic specimen measurements were available for review. Primary tumor size from the MRI was independently measured by a single diagnostic radiologist (P.M.) who was blinded to the pathology reports. Pathologic tumor measurements from gross specimens were obtained from the pathology reports. The maximum dimensions of tumor measured in any plane on the MRI and the gross specimen were compared. The median difference between the pathology sample and the MRI measurements was calculated. A paired t test was conducted to test for differences between the MRI and pathology measurements. The Pearson correlation coefficient was used to measure the association of disparity between the MRI and pathology sizes with the pathology size. Disparities relative to pathology size were also examined and tested for significance using a 1-sample t test. Results: The median patient age was 64.5 years. The primary site was pancreatic head in 81 patients, body in 4, and tail in 7. Three patients were American Joint Commission on Cancer stage IA, 7 stage IB, 21 stage IIA, 58 stage IIB, and 3 stage III. The 3D VIBE MRI underestimated tumor size by a median difference of 4 mm (range, −34-22 mm). The median largest tumor dimensions on MRI and pathology specimen were 2.65 cm (range, 1.5-9.5 cm) and 3.2 cm (range, 1.3-10 cm), respectively. Conclusions: Contrast-enhanced 3D VIBE MRI underestimates tumor size by 4 mm when compared with pathologic specimen. Advanced abdominal MRI sequences warrant further investigation for radiation therapy planning in pancreatic adenocarcinoma before

  13. Development of a penetration friction apparatus (PFA) to measure the frictional performance of surgical suture

    NARCIS (Netherlands)

    Zhang, Gangqiang; Ren, Tianhui; Lette, Walter; Zeng, Xiangqiong; van der Heide, Emile

    2017-01-01

    Nowadays there is a wide variety of surgical sutures available in the market. Surgical sutures have different sizes, structures, materials and coatings, whereas they are being used for various surgeries. The frictional performances of surgical sutures have been found to play a vital role in their

  14. Technique of manufacturing specimen of irradiated fuel rods

    International Nuclear Information System (INIS)

    Min, Duck Seok; Seo, Hang Seok; Min, Duck Kee; Koo, Dae Seo; Lee, Eun Pyo; Yang, Song Yeol

    1999-04-01

    Technique of manufacturing specimen of irradiated fuel rods to perform efficient PIE is developed by analyzing the relation between requiring time of manufacturing specimen and manufacturing method in irradiated fuel rods. It takes within an hour to grind 1 mm of specimen thickness under 150 rpm in speed of grinding, 600 g gravity in force using no.120, no.240, no.320 of grinding paper. In case of no.400 of grinding paper, it takes more an hour to grind the same thickness as above. It takes up to a quarter to grind 80-130 μm in specimen thickness using no.400 of grinding paper. When grinding time goes beyond 15 minutes, the grinding thickness of specimen does not exist. The polishing of specimen with 150 Rpms in speed of grinding machine, 600 g gravity in force, 10 minutes in polishing time using diamond paste 15 μm on polishing cloths amounts to 50 μm in specimen thickness. In case of diamond paste 9 μm on polishing cloth, the polishing of specimen amounts to 20 μm. The polishing thickness of specimen with 15 minutes in polishing time using 6 μm, 3 μm, 1 μm, 1/4 μm does not exist. Technique of manufacturing specimen of irradiated fuel rods will have application to the destructive examination of PIE. (author). 6 refs., 1 tab., 10 figs

  15. Step-wise integration of single-port laparoscopic surgery into routine colorectal surgical practice by use of a surgical glove port.

    Science.gov (United States)

    Hompes, R; Lindsey, I; Jones, O M; Guy, R; Cunningham, C; Mortensen, N J; Cahill, R A

    2011-06-01

    The cost associated with single-port laparoscopic access devices may limit utilisation of single-port laparoscopic surgery by colorectal surgeons. This paper describes a simple and cheap access modality that has facilitated the widespread adoption of single-port technology in our practice both as a stand-alone procedure and as a useful adjunct to traditional multiport techniques. A surgical glove port is constructed by applying a standard glove onto the rim of the wound protector/retractor used during laparoscopic resectional colorectal surgery. To illustrate its usefulness, we present our total experience to date and highlight a selection of patients presenting for a range of elective colorectal surgery procedures. The surgical glove port allowed successful completion of 25 single-port laparoscopic procedures (including laparoscopic adhesiolysis, ileo-rectal anastomosis, right hemicolectomy, total colectomy and low anterior resection) and has been used as an adjunct in over 80 additional multiport procedures (including refashioning of a colorectal anastomosis made after specimen extraction during a standard multiport laparoscopic anterior resection). This simple, efficient device can allow use of single-port laparoscopy in a broader spectrum of patients either in isolation or in combination with multiport surgery than may be otherwise possible for economic reasons. By separating issues of cost from utility, the usefulness of the technical advance inherent within single-port laparoscopy for colorectal surgery can be better appreciated. We endorse the creative innovation inherent in this approach as surgical practice continues to evolve for ever greater patient benefit.

  16. Specimen loading list for the varying temperature experiment

    International Nuclear Information System (INIS)

    Qualls, A.L.; Sitterson, R.G.

    1998-01-01

    The varying temperature experiment HFIR-RB-13J has been assembled and inserted in the reactor. Approximately 5300 specimens were cleaned, inspected, matched, and loaded into four specimen holders. A listing of each specimen loaded into the steady temperature holder, its position in the capsule, and the identification of the corresponding specimen loaded into the varying temperature holder is presented in this report

  17. Recent advances on Charpy specimen reconstitution techniques

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Arnaldo H.P.; Lobo, Raquel M.; Miranda, Carlos Alexandre J., E-mail: aandrade@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    Charpy specimen reconstitution is widely used around the world as a tool to enhance or supplement surveillance programs of nuclear reactor pressure vessels. The reconstitution technique consists in the incorporation of a small piece from a previously tested specimen into a compound specimen, allowing to increase the number of tests. This is especially important if the available materials is restricted and fracture mechanics parameter have to be determined. The reconstitution technique must fulfill some demands, among them tests results like the original standard specimens and the loaded material of the insert must not be influenced by the welding and machining procedure. It is known that reconstitution of Charpy specimens may affect the impact energy in a consequence of the constraint of plastic deformation by the hardened weldment and HAZ. This paper reviews some recent advances of the reconstitution technique and its applications. (author)

  18. Recent advances on Charpy specimen reconstitution techniques

    International Nuclear Information System (INIS)

    Andrade, Arnaldo H.P.; Lobo, Raquel M.; Miranda, Carlos Alexandre J.

    2017-01-01

    Charpy specimen reconstitution is widely used around the world as a tool to enhance or supplement surveillance programs of nuclear reactor pressure vessels. The reconstitution technique consists in the incorporation of a small piece from a previously tested specimen into a compound specimen, allowing to increase the number of tests. This is especially important if the available materials is restricted and fracture mechanics parameter have to be determined. The reconstitution technique must fulfill some demands, among them tests results like the original standard specimens and the loaded material of the insert must not be influenced by the welding and machining procedure. It is known that reconstitution of Charpy specimens may affect the impact energy in a consequence of the constraint of plastic deformation by the hardened weldment and HAZ. This paper reviews some recent advances of the reconstitution technique and its applications. (author)

  19. Transition Fracture Toughness Characterization of Eurofer 97 Steel using Pre-Cracked Miniature Multi-notch Bend Bar Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Xiang [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Sokolov, Mikhail A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Linton, Kory D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Clowers, Logan N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Katoh, Yutai [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-11-01

    In this report, we present the feasibility study of using pre-cracked miniature multi-notch bend bar specimens (M4CVN) with a dimension of 45mm (length) x 3.3mm (width) x 1.65mm (thickness) to characterize the transition fracture toughness of Eurofer97 based on the ASTM E1921 Master Curve method. From literature survey results, we did not find any obvious specimen size effects on the measured fracture toughness of unirradiated Eurofer97. Nonetheless, in order to exclude the specimen size effect on the measured fracture toughness of neutron irradiated Eurofer97, comparison of results obtained from larger size specimens with those from smaller size specimens after neutron irradiation is necessary, which is not practical and can be formidably expensive. However, limited literature results indicate that the transition fracture toughness of Eurofer97 obtained from different specimen sizes and geometries followed the similar irradiation embrittlement trend. We then described the newly designed experimental setup to be used for testing neutron irradiated Eurofer97 pre-cracked M4CVN bend bars in the hot cell. We recently used the same setup for testing neutron irradiated F82H pre-cracked miniature multi-notch bend bars with great success. Considering the similarity in materials, specimen types, and the nature of tests between Eurofer97 and F82H, we believe the newly designed experimental setup can be used successfully in fracture toughness testing of Eurofer97 pre-cracked M4CVN specimens.

  20. Abortion - surgical

    Science.gov (United States)

    Suction curettage; Surgical abortion; Elective abortion - surgical; Therapeutic abortion - surgical ... Surgical abortion involves dilating the opening to the uterus (cervix) and placing a small suction tube into the uterus. ...

  1. IgG4-positive cell infiltration in various cardiovascular disorders - results from histopathological analysis of surgical samples.

    Science.gov (United States)

    Hourai, Ryoto; Kasashima, Satomi; Sohmiya, Koichi; Yamauchi, Yohei; Ozawa, Hideki; Hirose, Yoshinobu; Ogino, Yasuhiro; Katsumata, Takahiro; Daimon, Masahiro; Fujita, Shu-Ichi; Hoshiga, Masaaki; Ishizaka, Nobukazu

    2017-02-03

    The diagnosis of Immunoglobulin G4 (IgG4)-related disease (IgG4-RD), in general, depends on serum IgG4 concentrations and histopathological findings; therefore, diagnosis of IgG4-RD in cardiovascular organs/tissues is often difficult owing to the risk of tissue sampling. Prevalence of IgG4-positive lymphoplasmacytic infiltration in 103 consecutive cardiovascular surgical samples from 98 patients with various cardiovascular diseases was analyzed immunohistochemically. The diagnoses of the enrolled patients included aortic aneurysm (abdominal, n = 8; thoracic, n = 9); aortic dissection (n = 20); aortic stenosis (n = 24), aortic regurgitation (n = 10), and mitral stenosis/regurgitation (n = 17). In total, 10 (9.7%) of the 103 specimens showed IgG4-positive cell infiltration with various intensities; five of these were aortic valve specimens from aortic stenosis, and IgG4-positive cell infiltration was present at >10 /HPF in three of them. In one aortic wall sample from an abdominal aortic aneurysm, various histopathological features of IgG4-RD, such as IgG4-positive cell infiltration, obliterating phlebitis, and storiform fibrosis, were observed. IgG4-positive cell infiltration was observed in 9.7% of the surgical cardiovascular specimens, mainly in the aortic valve from aortic stenosis and in the aortic wall from aortic aneurysm. Whether IgG4-positive cell infiltration has pathophysiological importance in the development or progression of cardiovascular diseases should be investigated in future studies.

  2. Effects of drying conditions, admixtures and specimen size on shrinkage strains

    International Nuclear Information System (INIS)

    Al-Saleh, Saleh A.; Al-Zaid, Rajeh Z.

    2006-01-01

    The paper presents the results of an experimental investigation on the effects of drying conditions, specimen size and presence of plasticizing admixture on the development of shrinkage strains. The measurements are taken in a harsh (50 deg. C and 5% R.H.) and a moderate environment (28 deg. C and 50% R.H.). The results include strain development at various levels of cross sections of concrete prisms. The drying conditions are found to be the dominant parameter affecting the shrinkage strain development particularly in specimens of smaller sizes. The effect of plasticizing admixture on shrinkage strains is negligible

  3. Post surgical complications from students' large animal surgical ...

    African Journals Online (AJOL)

    A retrospective study of post surgical complications was conducted on records of students' Large Animal Surgical Laboratories in the Faculty of Veterinary Medicine (F.V.M.), Ahmadu Bello University (A.B.U), Zaria from 1989 to 1993. Three hundred and eleven surgical complications were recorded from five surgical ...

  4. Evaluation of DC electric field distribution of PPLP specimen based on the measurement of electrical conductivity in LN{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Jae-Sang; Seong, Jae-Kyu; Shin, Woo-Ju; Lee, Jong-Geon [Hanyang University, 408-2, 4th Engineering Bldg, Sa 3-dong, Sangrok-gu, Ansan 426-791 (Korea, Republic of); Cho, Jeon-Wook; Ryoo, Hee-Suk [Korea Electrotechnology Research Institute, Changwon, Gyungnam 641-120 (Korea, Republic of); Lee, Bang-Wook, E-mail: bangwook@hanyang.ac.kr [Hanyang University, 408-2, 4th Engineering Bldg, Sa 3-dong, Sangrok-gu, Ansan 426-791 (Korea, Republic of)

    2013-11-15

    Highlights: •The electrical conductivity of PPLP in LN{sub 2} was successfully measured. •Based on the measured value of PPLP, DC field analysis was performed. •The electric field distribution was altered according to the DC applying stages. •The maximum electric field was observed during polarity reversal situation. •DC field analysis is important to determine the optimum design of DC HTS devices. -- Abstract: High temperature superconducting (HTS) cable has been paid much attention due to its high efficiency and high current transportation capability, and it is also regarded as eco-friendly power cable for the next generation. Especially for DC HTS cable, it has more sustainable and stable properties compared to AC HTS cable due to the absence of AC loss in DC HTS cable. Recently, DC HTS cable has been investigated competitively all over the world, and one of the key components of DC HTS cable to be developed is a cable joint box considering HVDC environment. In order to achieve the optimum insulation design of the joint box, analysis of DC electric field distribution of the joint box is a fundamental process to develop DC HTS cable. Generally, AC electric field distribution depends on relative permittivity of dielectric materials but in case of DC, electrical conductivity of dielectric material is a dominant factor which determines electric field distribution. In this study, in order to evaluate DC electric field characteristics of the joint box for DC HTS cable, polypropylene laminated paper (PPLP) specimen has been prepared and its DC electric field distribution was analyzed based on the measurement of electrical conductivity of PPLP in liquid nitrogen (LN{sub 2}). Electrical conductivity of PPLP in LN{sub 2} has not been reported yet but it should be measured for DC electric field analysis. The experimental works for measuring electrical conductivity of PPLP in LN{sub 2} were presented in this paper. Based on the experimental works, DC electric

  5. Granule cell dispersion is not a predictor of surgical outcome in temporal lobe epilepsy with mesial temporal sclerosis.

    Science.gov (United States)

    da Costa Neves, Rafael Scarpa; Jardim, Anaclara Prada; Caboclo, Luís Otávio; Lancellotti, Carmen; Marinho, Taissa Ferrari; Hamad, Ana Paula; Marinho, Murilo; Centeno, Ricardo; Cavalheiro, Esper Abrão; Scorza, Carla Alessandra; Targas Yacubian, Elza Márcia

    2013-01-01

    The aim of this retrospective study of a series of patients with mesial temporal lobe epilepsy (MTLE) and mesial temporal sclerosis (MTS) was to analyze the association of granule cell dispersion (GCD) with surgical prognosis, patterns of MTS and clinical data. Hippocampal specimens from 66 patients with MTLE and unilateral MTS and from 13 controls were studied. Quantitative neuropathological evaluation was performed on NeuN-stained hippocampal sections. Patients' clinical data, types of MTS and surgical outcome were reviewed. GCD occurred in 45.5% of cases and was not correlated with clinical variable. More severe neuronal loss was observed in patients with GCD. Except for MTS Type 2 - observed only in four no- GCD patients - groups did not differ with respect to the types of MTS. Surgical outcome was similar in both groups. In conclusion, GCD was associated with the degree of hippocampal cell loss, but was not a predictor of surgical outcome.

  6. Quantification of surgical blood loss.

    Science.gov (United States)

    Lee, Marcel H; Ingvertsen, Britt T; Kirpensteijn, Jolle; Jensen, Asger L; Kristensen, Annemarie T

    2006-06-01

    To compare gravimetric and colorimetric methods of quantifying surgical blood loss, and to determine if there is a correlation between preoperative hemostatic tests (buccal mucosa bleeding time [BMBT] and intraoperative blood loss). Prospective clinical study. Dogs (n=15) admitted for cutaneous tumor excision, orthopedic procedure, or exploratory laparotomy. Intraoperative blood loss was quantified by measuring irrigation fluid and weighing surgical sponges used for blood and fluid collection during surgery. Results of gravimetric measurements were then correlated to blood loss quantified using spectrophotometric analysis of hemoglobin (Hb) content. Hemostatic variables including BMBT were measured before surgery and compared with the calculated amount of blood loss. Blood loss quantified by gravimetric measurement showed a significant correlation with colorimetric determination of Hb content in surgical sponges and collected irrigation fluid (r=0.93, P<.0001). BMBT correlated weakly but significantly with intraoperative blood loss (r=0.56, P<.05). Quantifying intraoperative blood loss using spectrophotometric Hb analysis accurately assessed the amount of blood loss; however, it is a time-consuming procedure, primarily applicable as a research tool. Gravimetric evaluation of intraoperative blood loss was found to be an accurate method, which can be recommended for use in a clinical setting. Estimation of blood loss using a gravimetric method is accurate and applicable in the clinical setting and provides surgeons with a simple and objective tool to evaluate intraoperative blood loss.

  7. Risk-adjusted morbidity in teaching hospitals correlates with reported levels of communication and collaboration on surgical teams but not with scale measures of teamwork climate, safety climate, or working conditions.

    Science.gov (United States)

    Davenport, Daniel L; Henderson, William G; Mosca, Cecilia L; Khuri, Shukri F; Mentzer, Robert M

    2007-12-01

    Since the Institute of Medicine patient safety reports, a number of survey-based measures of organizational climate safety factors (OCSFs) have been developed. The goal of this study was to measure the impact of OCSFs on risk-adjusted surgical morbidity and mortality. Surveys were administered to staff on general/vascular surgery services during a year. Surveys included multiitem scales measuring OCSFs. Additionally, perceived levels of communication and collaboration with coworkers were assessed. The National Surgical Quality Improvement Program was used to assess risk-adjusted morbidity and mortality. Correlations between outcomes and OCSFs were calculated and between outcomes and communication/collaboration with attending and resident doctors, nurses, and other providers. Fifty-two sites participated in the survey: 44 Veterans Affairs and 8 academic medical centers. A total of 6,083 surveys were returned, for a response rate of 52%. The OCSF measures of teamwork climate, safety climate, working conditions, recognition of stress effects, job satisfaction, and burnout demonstrated internal validity but did not correlate with risk-adjusted outcomes. Reported levels of communication/collaboration with attending and resident doctors correlated with risk-adjusted morbidity. Survey-based teamwork, safety climate, and working conditions scales are not confirmed to measure organizational factors that influence risk-adjusted surgical outcomes. Reported communication/collaboration with attending and resident doctors on surgical services influenced patient morbidity. This suggests the importance of doctors' coordination and decision-making roles on surgical teams in providing high-quality and safe care. We propose risk-adjusted morbidity as an effective measure of surgical patient safety.

  8. Assessment of Surgical Skills and Competency.

    Science.gov (United States)

    Bhatti, Nasir I

    2017-10-01

    Evaluation of surgical skills and competency are important aspects of the medical education process. Measurable and reproducible methods of assessment with objective feedback are essential components of surgical training. Objective Structured Assessment of Technical Skills (OSATS) is widely used across the medical specialties and otolaryngology-specific tools have been developed and validated for sinus and mastoid surgery. Although assessment of surgical skills can be time-consuming and requires human and financial resources, new evaluation methods and emerging technology may alleviate these barriers while also improving data collection practices. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Surgical accuracy of three-dimensional virtual planning

    DEFF Research Database (Denmark)

    Stokbro, Kasper; Aagaard, Esben; Torkov, Peter

    2016-01-01

    This retrospective study evaluated the precision and positional accuracy of different orthognathic procedures following virtual surgical planning in 30 patients. To date, no studies of three-dimensional virtual surgical planning have evaluated the influence of segmentation on positional accuracy...... and transverse expansion. Furthermore, only a few have evaluated the precision and accuracy of genioplasty in placement of the chin segment. The virtual surgical plan was compared with the postsurgical outcome by using three linear and three rotational measurements. The influence of maxillary segmentation...

  10. 7 CFR 97.8 - Specimen requirements.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Specimen requirements. 97.8 Section 97.8 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... required by the examiner to furnish representative specimens of the variety, or its flower, fruit, or seeds...

  11. Three-Dimensional Printing Surgical Applications.

    Science.gov (United States)

    AlAli, Ahmad B; Griffin, Michelle F; Butler, Peter E

    2015-01-01

    Three-dimensional printing, a technology used for decades in the industrial field, gains a lot of attention in the medical field for its potential benefits. With advancement of desktop printers, this technology is accessible and a lot of research is going on in the medical field. To evaluate its application in surgical field, which may include but not limited to surgical planning, surgical education, implants, and prosthesis, which are the focus of this review. Research was conducted by searching PubMed, Web of science, and other reliable sources. We included original articles and excluded articles based on animals, those more than 10 years old, and those not in English. These articles were evaluated, and relevant studies were included in this review. Three-dimensional printing shows a potential benefit in surgical application. Printed implants were used in patient in a few cases and show successful results; however, longer follow-up and more trials are needed. Surgical and medical education is believed to be more efficient with this technology than the current practice. Printed surgical instrument and surgical planning are also believed to improve with three-dimensional printing. Three-dimensional printing can be a very powerful tool in the near future, which can aid the medical field that is facing a lot of challenges and obstacles. However, despite the reported results, further research on larger samples and analytical measurements should be conducted to ensure this technology's impact on the practice.

  12. Agreement for HPV genotyping detection between self-collected specimens on a FTA cartridge and clinician-collected specimens

    Science.gov (United States)

    Guan, YaoYao; Gravitt, Patti E.; Howard, Roslyn; Eby, Yolanda J.; Wang, Shaoming; Li, Belinda; Feng, Changyan; Qiao, You-Lin; Castle, Philip E.

    2016-01-01

    The current method of transporting self-collected cervicovaginal specimen for HPV DNA testing relies on liquid based medium, which is challenging and expensive to transport. A novel, dry storage and transportation device, Whatman indicating FTA™ Elute Cartridge, avoids some of the pitfalls of liquid-based medium. This method has been shown to be comparable to liquid-based collection medium, but relative performance of self-collected (SC) and clinician-collected (CC) samples onto FTA cards has not been reported. The objective of this study is to compare the analytic performance of self- and clinician-collected samples onto FTA cartridges for the detection of carcinogenic HPV using Linear Array. There was a 91% agreement, 69% positive agreement, and kappa of 0.75 between the clinician-collected and self-collected specimens for detection of any carcinogenic HPV genotype. When the HPV results were categorized hierarchically according to cervical cancer risk, there was no difference in the distribution of the HPV results for the clinician- and self-collected specimens (p = 0.7). This study concludes that FTA elute cartridge is a promising method of specimen transport for cervical cancer screening programs considering using self-collected specimen and HPV testing. Larger studies with clinical endpoints are now needed to assess the clinical performance. PMID:23370404

  13. Standard practice for preparation and use of Bent-Beam stress-corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This practice covers procedures for designing, preparing, and using bent-beam stress-corrosion specimens. 1.2 Different specimen configurations are given for use with different product forms, such as sheet or plate. This practice applicable to specimens of any metal that are stressed to levels less than the elastic limit of the material, and therefore, the applied stress can be accurately calculated or measured (see Note 1). Stress calculations by this practice are not applicable to plastically stressed specimens. Note 1—It is the nature of these practices that only the applied stress can be calculated. Since stress-corrosion cracking is a function of the total stress, for critical applications and proper interpretation of results, the residual stress (before applying external stress) or the total elastic stress (after applying external stress) should be determined by appropriate nondestructive methods, such as X-ray diffraction (1). 1.3 Test procedures are given for stress-corrosion testing by ex...

  14. Retrospective analysis of heavy metal contamination in Rhode Island based on old and new herbarium specimens1

    Science.gov (United States)

    Rudin, Sofia M.; Murray, David W.; Whitfeld, Timothy J. S.

    2017-01-01

    Premise of the study: Herbarium specimens may provide a record of past environmental conditions, including heavy metal pollution. To explore this potential, we compared concentrations of copper, lead, and zinc in historical and new collections from four sites in Rhode Island, USA. Methods: We compared historical specimens (1846 to 1916) to congener specimens collected in 2015 at three former industrial sites in Providence, Rhode Island, and one nonindustrial site on Block Island. Leaf material was prepared by UltraWAVE SRC Microwave Digestion, and heavy metal concentrations were measured by inductively coupled plasma–atomic emission spectroscopy. Results: Heavy metal concentrations in the historical and new specimens were measurable for all elements tested, and levels of copper and zinc were comparable in the historical and 2015 collections. By contrast, the concentration of lead declined at all sites over time. Significant variability in heavy metal concentration was observed between taxa, reflecting their varied potential for elemental accumulation. Discussion: It seems clear that herbarium specimens can be used to evaluate past levels of pollution and assess local environmental changes. With careful sampling effort, these specimens can be a valuable part of environmental science research. Broadening the possible applications for herbarium collections in this way increases their relevance in an era of reduced funding for collections-based research. PMID:28090410

  15. Thermal property testing technique on micro specimen

    International Nuclear Information System (INIS)

    Baba, Tetsuya; Kishimoto, Isao; Taketoshi, Naoyuki

    2000-01-01

    This study aims at establishment of further development on some testing techniques on the nuclear advanced basic research accumulated by the National Research Laboratory of Metrology for ten years. For this purpose, a technology to test heat diffusion ratio and specific heat capacity of less than 3 mm in diameter and 1 mm in thickness of micro specimen and technology to test heat diffusion ratio at micro area of less than 1 mm in area along cross section of less than 10 mm in diameter of column specimen were developed to contribute to common basic technology supporting the nuclear power field. As a result, as an element technology to test heat diffusion ratio and specific heat capacity of the micro specimen, a specimen holding technique stably to hold a micro specimen with 3 mm in diameter could be developed. And, for testing the specific heat capacity by using the laser flush differential calorimetry, a technique to hold two specimen of 5 mm in diameter at their proximities was also developed. In addition, by promoting development of thermal property data base capable of storing thermal property data obtained in this study and with excellent workability in this 1998 fiscal year a data in/out-put program with graphical user interface could be prepared. (G.K.)

  16. Comparative study on Charpy specimen reconstitution techniques

    International Nuclear Information System (INIS)

    Bourdiliau, B.; Decroix, G.-M.; Averty, X.; Wident, P.; Bienvenu, Y.

    2011-01-01

    Highlights: → Welding processes are used to reconstitute previously tested Charpy specimens. → Stud welding is preferred for a quick installation, almost immediately operational. → Friction welding produces better quality welds, but requires a development effort. - Abstract: Reconstitution techniques are often used to allow material from previously fractured Charpy-V specimens to be reused for additional experiments. This paper presents a comparative experimental study of various reconstitution techniques and evaluates the feasibility of these methods for future use in shielded cells. The following techniques were investigated: arc stud welding, 6.0 kW CO 2 continuous wave laser welding, 4.5 kW YAG continuous wave laser welding and friction welding. Subsize Charpy specimens were reconstituted using a 400 W YAG pulsed wave laser. The best result was obtained with arc stud welding; the resilience of the reconstituted specimens and the load-displacement curves agreed well with the reference specimens, and the temperature elevation caused by the welding process was limited to the vicinity of the weld. Good results were also obtained with friction welding; this process led to the best quality welds. Laser welding seems to have affected the central part of the specimens, thus leading to different resilience values and load-displacement curves.

  17. Bright field electron microscopy of biological specimens

    International Nuclear Information System (INIS)

    Johansen, B.V.

    1976-01-01

    A preirradiation procedure is described which preserves negatively stained morphological features in bright field electron micrographs to a resolution of about 1.2 nm. Prior to microscopy the pre-irradiation dose (1.6 x 10 -3 C cm -2 ) is given at low electron optical magnification at five different areas on the grid (the centre plus four 'corners'). This pre-irradiation can be measured either with a Faraday cage or through controlled exposure-developing conditions. Uranyl formate stained T2 bacteriophages and stacked disk aggregates of Tobacco Mosaic Virus (TMV) protein served as test objects. A comparative study was performed on specimens using either the pre-irradiation procedure or direct irradiation by the 'minimum beam exposure' technique. Changes in the electron diffraction pattern of the stain-protein complex and the disappearance of certain morphological features in the specimens were both used in order to compare the pre-irradiation method with the direct exposure technique. After identical electron exposures the pre-irradiation approach gave a far better preservation of specimen morphology. Consequently this procedure gives the microscopist more time to select and focus appropriate areas for imaging before deteriorations take place. The investigation also suggested that microscopy should be carried out between 60,000 and 100,000 times magnification. Within this magnification range, it is possible to take advantage of the phase contrast transfer characteristics of the objective lens while the electron load on the object is kept at a moderate level. Using the pre-irradiation procedure special features of the T2 bacteriophage morphology could be established. (author)

  18. Enzymatic detection of formalin-fixed museum specimens for DNA analysis and enzymatic maceration of formalin-fixed specimens

    DEFF Research Database (Denmark)

    Sørensen, Margrethe; Redsted Rasmussen, Arne; Simonsen, Kim Pilkjær

    2016-01-01

    % ethanol. The method was subsequently tested on wild-living preserved specimens and an archived specimen. The protease enzyme used was SavinaseH 16 L, Type EX from Novozymes A/S. The enzymatic screening test demands only simple laboratory equipment. The method is useful for natural history collections...

  19. Prediction of mass absorption coefficients from inelastically scattered X-radiation for specimens of less than 'infinite thickness'

    International Nuclear Information System (INIS)

    Kieser, R.; Mulligan, T.J.

    1979-01-01

    An equation is developed which describes the X-ray scatter radiation from specimens of any thickness. This equation suggests that a specimen's mass absorption coefficient can be determined from its inelastically scattered X-radiation not only when the specimen is 'infinitely thick' but also when it is of 'intermediate thickness'. Measurements have been carried out with a standard energy-dispersive X-ray spectrometer on specimens of 'intermediate thickness'. Good agreement is obtained between the mass absorption coefficients that are calculated from the scattered radiation and those obtained on the basis of tabulated mass absorption coefficients for the elements. (author)

  20. Closeout of JOYO-1 Specimen Fabrication Efforts

    International Nuclear Information System (INIS)

    ME Petrichek; JL Bump; RF Luther

    2005-01-01

    Fabrication was well under way for the JOYO biaxial creep and tensile specimens when the NR Space program was canceled. Tubes of FS-85, ASTAR-811C, and T-111 for biaxial creep specimens had been drawn at True Tube (Paso Robles, CA), while tubes of Mo-47.5 Re were being drawn at Rhenium Alloys (Cleveland, OH). The Mo-47.5 Re tubes are now approximately 95% complete. Their fabrication and the quantities produced will be documented at a later date. End cap material for FS-85, ASTAR-811C, and T-111 had been swaged at Pittsburgh Materials Technology, Inc. (PMTI) (Large, PA) and machined at Vangura (Clairton, PA). Cutting of tubes, pickling, annealing, and laser engraving were in process at PMTI. Several biaxial creep specimen sets of FS-85, ASTAR-811C, and T-111 had already been sent to Pacific Northwest National Laboratory (PNNL) for weld development. In addition, tensile specimens of FS-85, ASTAR-811C, T-111, and Mo-47.5 Re had been machined at Kin-Tech (North Huntington, PA). Actual machining of the other specimen types had not been initiated. Flowcharts 1-3 detail the major processing steps each piece of material has experienced. A more detailed description of processing will be provided in a separate document [B-MT(SRME)-51]. Table 1 lists the in-process materials and finished specimens. Also included are current metallurgical condition of these materials and specimens. The available chemical analyses for these alloys at various points in the process are provided in Table 2

  1. Surgical lighting

    NARCIS (Netherlands)

    Knulst, A.J.

    2017-01-01

    The surgical light is an important tool for surgeons to create and maintain good visibility on the surgical task. Chapter 1 gives background to the field of (surgical) lighting and related terminology. Although the surgical light has been developed strongly since its introduction a long time ago,

  2. Surgical smoke.

    Science.gov (United States)

    Fan, Joe King-Man; Chan, Fion Siu-Yin; Chu, Kent-Man

    2009-10-01

    Surgical smoke is the gaseous by-product formed during surgical procedures. Most surgeons, operating theatre staff and administrators are unaware of its potential health risks. Surgical smoke is produced by various surgical instruments including those used in electrocautery, lasers, ultrasonic scalpels, high speed drills, burrs and saws. The potential risks include carbon monoxide toxicity to the patient undergoing a laparoscopic operation, pulmonary fibrosis induced by non-viable particles, and transmission of infectious diseases like human papilloma virus. Cytotoxicity and mutagenicity are other concerns. Minimisation of the production of surgical smoke and modification of any evacuation systems are possible solutions. In general, a surgical mask can provide more than 90% protection to exposure to surgical smoke; however, in most circumstances it cannot provide air-tight protection to the user. An at least N95 grade or equivalent respirator offers the best protection against surgical smoke, but whether such protection is necessary is currently unknown.

  3. Simultaneous specimen and stage cleaning device for analytical electron microscope

    Science.gov (United States)

    Zaluzec, Nestor J.

    1996-01-01

    An improved method and apparatus are provided for cleaning both a specimen stage, a specimen and an interior of an analytical electron microscope (AEM). The apparatus for cleaning a specimen stage and specimen comprising a plasma chamber for containing a gas plasma and an air lock coupled to the plasma chamber for permitting passage of the specimen stage and specimen into the plasma chamber and maintaining an airtight chamber. The specimen stage and specimen are subjected to a reactive plasma gas that is either DC or RF excited. The apparatus can be mounted on the analytical electron microscope (AEM) for cleaning the interior of the microscope.

  4. Quantitative sensing of corroded steel rebar embedded in cement mortar specimens using ultrasonic testing

    Science.gov (United States)

    Owusu Twumasi, Jones; Le, Viet; Tang, Qixiang; Yu, Tzuyang

    2016-04-01

    Corrosion of steel reinforcing bars (rebars) is the primary cause for the deterioration of reinforced concrete structures. Traditional corrosion monitoring methods such as half-cell potential and linear polarization resistance can only detect the presence of corrosion but cannot quantify it. This study presents an experimental investigation of quantifying degree of corrosion of steel rebar inside cement mortar specimens using ultrasonic testing (UT). A UT device with two 54 kHz transducers was used to measure ultrasonic pulse velocity (UPV) of cement mortar, uncorroded and corroded reinforced cement mortar specimens, utilizing the direct transmission method. The results obtained from the study show that UPV decreases linearly with increase in degree of corrosion and corrosion-induced cracks (surface cracks). With respect to quantifying the degree of corrosion, a model was developed by simultaneously fitting UPV and surface crack width measurements to a two-parameter linear model. The proposed model can be used for predicting the degree of corrosion of steel rebar embedded in cement mortar under similar conditions used in this study up to 3.03%. Furthermore, the modeling approach can be applied to corroded reinforced concrete specimens with additional modification. The findings from this study show that UT has the potential of quantifying the degree of corrosion inside reinforced cement mortar specimens.

  5. Agreement for HPV genotyping detection between self-collected specimens on a FTA cartridge and clinician-collected specimens.

    Science.gov (United States)

    Guan, Yaoyao; Gravitt, Patti E; Howard, Roslyn; Eby, Yolanda J; Wang, Shaoming; Li, Belinda; Feng, Changyan; Qiao, You-Lin; Castle, Philip E

    2013-04-01

    The current method of transporting self-collected cervicovaginal specimen for HPV DNA testing relies on liquid based medium, which is challenging and expensive to transport. A novel, dry storage and transportation device, Whatman indicating FTA™ Elute Cartridge, avoids some of the pitfalls of liquid-based medium. This method has been shown to be comparable to liquid-based collection medium, but relative performance of self-collected (SC) and clinician-collected (CC) samples onto FTA cards has not been reported. The objective of this study is to compare the analytic performance of self- and clinician-collected samples onto FTA cartridges for the detection of carcinogenic HPV using Linear Array. There was a 91% agreement, 69% positive agreement, and kappa of 0.75 between the clinician-collected and self-collected specimens for detection of any carcinogenic HPV genotype. When the HPV results were categorized hierarchically according to cervical cancer risk, there was no difference in the distribution of the HPV results for the clinician- and self-collected specimens (p=0.7). This study concludes that FTA elute cartridge is a promising method of specimen transport for cervical cancer screening programs considering using self-collected specimen and HPV testing. Larger studies with clinical endpoints are now needed to assess the clinical performance. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. The distinct element analysis for swelling pressure test of bentonite. Discussion on the effects of wall friction force and aspect ratio of specimen

    International Nuclear Information System (INIS)

    Shimizu, Hiroyuki; Kikuchi, Hirohito; Fujita, Tomoo; Tanai, Kenji

    2011-10-01

    For geological isolation systems for radioactive waste, bentonite based material is assumed to be used as a buffer material. The swelling characteristics of the bentonite based material are expected to fill up the void space around the radioactive wastes by swelling. In general, swelling characteristics and properties of bentonite are evaluated by the laboratory tests. However, due to the lack of standardization of testing method for bentonite, the accuracy and reproducibility of the testing results are not sufficiently proved. In this study, bentonite swelling pressure test were simulated by newly developed Distinct Element Method (DEM) code, and the effects of wall friction force and aspect ratio of bentonite specimen were discussed. As a result, the followings were found. In the beginning of the swelling pressure test, since swelling occurs only around the fluid injection side of the specimen, wall friction force acts only in the swelling area and the specimen moves to opposite side from fluid injection side. However, when the entire specimen started swelling, displacement of the specimen prevented by the wall friction force, and the specimen is pressed against the pressure measurement side. Then, the swelling pressure measured on the pressure measurement side increases. Such displacement in the specimen is significantly affected by the decreasing of mechanical properties and the difference of saturation in the bentonite specimen during the fluid infiltration. Moreover, when the aspect ratio of the specimen is large, the displacement of the particle in the specimen becomes large and the area on which the wall frictional force acts is also large. Therefore, measured swelling pressure increases more greatly as the aspect ratio of the specimen increases. To contributes to the standardization of laboratory test methods for bentonite, these effects of wall friction force revealed by the DEM simulation should be verified through laboratory experiments. (author)

  7. The Value of Large Sections in Surgical Pathology

    Directory of Open Access Journals (Sweden)

    Maria P. Foschini

    2012-01-01

    Full Text Available Large format sections (LS first have been introduced in breast pathology more than a century ago. Since then, they constituted for longtime a research tool to better understand breast microanatomy and the relationship between radiological images and pathological features. Similarly LS have been used to study neoplastic, inflammatory, and degenerative diseases affecting various organs, as brain, lung, gastrointentinal tract, bone, urinary tract, prostate, and placenta. Currently LS are mostly applied to diagnostic routine to better stage tumours such as prostate and breast carcinomas or to correlate radiologic imaging to gross specimens. The purpose of the present paper is to review the historical background and the basis of the applications of LS in surgical pathology, with special emphasis on breast tumours.

  8. A cylindrical specimen holder for electron cryo-tomography

    International Nuclear Information System (INIS)

    Palmer, Colin M.; Löwe, Jan

    2014-01-01

    The use of slab-like flat specimens for electron cryo-tomography restricts the range of viewing angles that can be used. This leads to the “missing wedge” problem, which causes artefacts and anisotropic resolution in reconstructed tomograms. Cylindrical specimens provide a way to eliminate the problem, since they allow imaging from a full range of viewing angles around the tilt axis. Such specimens have been used before for tomography of radiation-insensitive samples at room temperature, but never for frozen-hydrated specimens. Here, we demonstrate the use of thin-walled carbon tubes as specimen holders, allowing the preparation of cylindrical frozen-hydrated samples of ribosomes, liposomes and whole bacterial cells. Images acquired from these cylinders have equal quality at all viewing angles, and the accessible tilt range is restricted only by the physical limits of the microscope. Tomographic reconstructions of these specimens demonstrate that the effects of the missing wedge are substantially reduced, and could be completely eliminated if a full tilt range was used. The overall quality of these tomograms is still lower than that obtained by existing methods, but improvements are likely in future. - Highlights: • The missing wedge is a serious problem for electron cryo-tomography. • Cylindrical specimens allow the missing wedge to be eliminated. • Carbon nanopipettes can be used as cylindrical holders for tomography of frozen-hydrated specimens. • Cryo-tomography of cylindrical biological samples demonstrates a reduction of deleterious effects associated with the missing wedge

  9. Liability exposure for surgical robotics instructors.

    Science.gov (United States)

    Lee, Yu L; Kilic, Gokhan; Phelps, John Y

    2012-01-01

    Surgical robotics instructors provide an essential service in improving the competency of novice gynecologic surgeons learning robotic surgery and advancing surgical skills on behalf of patients. However, despite best intentions, robotics instructors and the gynecologists who use their services expose themselves to liability. The fear of litigation in the event of a surgical complication may reduce the availability and utility of robotics instructors. A better understanding of the principles of duty of care and the physician-patient relationship, and their potential applicability in a court of law likely will help to dismantle some concerns and uncertainties about liability. This commentary is not meant to discourage current and future surgical instructors but to raise awareness of liability issues among robotics instructors and their students and to recommend certain preventive measures to curb potential liability risks. Published by Elsevier Inc.

  10. Influence of specimen size/type on the fracture toughness of five irradiated RPV materials

    International Nuclear Information System (INIS)

    Sokolov, Mikhail A; Lucon, Enrico

    2015-01-01

    The Heavy-Section Steel Irradiation (HSSI) Program had previously irradiated five reactor pressure vessel (RPV) steels/welds at fast neutron fluxes of about 4 to 8 x 10 11 n/cm 2 /s (>1 MeV) to fluences from 0.5 to 3.4 10 19 n/cm 2 and at 288 °C. The unirradiated fracture toughness tests were performed by Oak Ridge National Laboratory with 12.7-mm and 25.4-mm thick (0.5T and 1T) compact specimens, while the HSSI Program provided tensile and 5 x 10-mm three-point bend specimens to SCK-CEN for irradiation in the in-pile section of the Belgian Reactor BR2 at fluxes > 10 13 n/cm 2 /s and subsequent testing by SCK-CEN. The BR2 irradiations were conducted at about 2 and 4 x 10 13 n/cm 2 /s with irradiation temperature between 295 °C and 300 °C (water temperature), and to fluences between 6 and 10 x 10 19 n/cm 2 . The irradiation-induced shifts of the Master Curve reference temperatures, ΔT 0 , for most of the materials deviated from the embrittlement correlations much more than expected, motivating the testing of 5 x 10-mm three-point bend specimens of all five materials in the unirradiated condition to eliminate specimen size and geometry as a variable. Tests of the unirradiated small bend specimens resulted in Master Curve reference temperatures, ΔT 0 , 25 °C to 53 °C lower than those from the larger compact specimens, meaning that the irradiation-induced reference temperature shifts, ΔT 0 , were larger than the initial measurements, resulting in much improved agreement between the measured and predicted fracture toughness shifts.

  11. Use of a surgical rehearsal platform and improvement in aneurysm clipping measures: results of a prospective, randomized trial.

    Science.gov (United States)

    Chugh, A Jessey; Pace, Jonathan R; Singer, Justin; Tatsuoka, Curtis; Hoffer, Alan; Selman, Warren R; Bambakidis, Nicholas C

    2017-03-01

    . CONCLUSIONS Preoperative rehearsal with SRP increased efficiency and safety in aneurysm microsurgery as demonstrated by the statistically significant improvement in time per clip used. Although the rest of the outcomes did not demonstrate statistically significant between-group differences, the fact that the SRP group showed improvement in mean values for all measures studied suggests that preoperative rehearsal may increase the efficiency and safety of aneurysm microsurgery. Future studies aimed at improving patient outcome and safety during surgical clipping of aneurysms will be needed to keep pace with the quickly advancing endovascular field.

  12. Surgical Assisting

    Science.gov (United States)

    ... instruction, including: Microbiology Pathophysiology Pharmacology Anatomy and physiology Medical terminology Curriculum . Course content includes: Advanced surgical anatomy Surgical microbiology Surgical pharmacology Anesthesia methods and agents Bioscience Ethical ...

  13. Paediatric Abdominal Surgical Emergencies in a General Surgical ...

    African Journals Online (AJOL)

    ... organized for general surgeons undertaking paediatric surgical emergencies. More paediatric surgeons should be trained and more paediatric surgical units should established in the country. Key Words: Paediatric Abdominal Surgical Emergencies; Paediatric Surgeons, General Surgeons. Journal of College of Medicine ...

  14. Replacement/Refurbishment of JSC/NASA POD Specimens

    Science.gov (United States)

    Castner, Willard L.

    2010-01-01

    The NASA Special NDE certification process requires demonstration of NDE capability by test per NASA-STD-5009. This test is performed with fatigue cracked specimens containing very small cracks. The certification test results are usually based on binomial statistics and must meet a 90/95 Probability of Detection (POD). The assumption is that fatigue cracks are tightly closed, difficult to detect, and inspectors and processes passing such a test are well qualified for inspecting NASA fracture critical hardware. The JSC NDE laboratory has what may be the largest inventory that exists of such fatigue cracked NDE demonstration specimens. These specimens were produced by the hundreds in the late 1980s and early 1990s. None have been produced since that time and the condition and usability of the specimens are questionable.

  15. The influence of specimen size on creep crack growth rate in cross-weld CT specimens cut out from a welded component

    International Nuclear Information System (INIS)

    Andersson, Peder; Segle, Peter; Samuelson, Lars Aa.

    1999-04-01

    A 3D finite element study of creep crack growth in cross-weld CT specimens with material properties of 2.25Cr1Mo at 550 deg C is carried out, where large strain and displacement theory is used. The creep crack growth rate is calculated using a creep ductility based damage model, in which the creep strain rate perpendicular to the crack plane ahead of the crack tip is integrated, considering the multiaxial stress state. The influence of specimen size on creep crack growth rate under constant load is given special attention, but the possibility to transfer results from cross-weld CT specimens to welded high temperature components is also investigated. The creep crack growth rate of a crack in a circumferentially welded pipe is compared with the creep crack growth rate of cross-weld CT specimens of three different sizes, cut out from the pipe. Although the constraint ahead of the crack tip is higher for a larger CT specimen, the creep crack growth rate is higher for a smaller specimen than for a larger one if they are loaded to attain the same stress intensity factor. If the specimens are loaded to the same C* value, however, a more complicated pattern occurs; depending on the material properties of the weldment constituents, the CT specimen with the intermediate size will either yield the highest or the lowest creep crack growth rate

  16. Impurity composition effect on work function in cylindrical specimens of niobium and low zirconium niobium base alloys

    International Nuclear Information System (INIS)

    Kobyakov, V.P.

    2000-01-01

    A study is made into poly- and single crystal cylindrical niobium specimens, prepared by various methods as well as into polycrystalline specimens of niobium base alloys doped with 1.2 and 1.6 % Zr. Thermionic work function is measured using a full current method. Several techniques are applied to determine the content of substitutional and interstitial impurities in specimens. The phase composition of polished section surface is also investigated. A work function increase is observed when a considerable amount of carbide phases occurs at the surface. This increase is comparable with the effect of going from a polycrystalline niobium specimen to a single crystal with (110) surface orientation [ru

  17. Accuracy of surgical wound drainage measurements: an analysis and comparison.

    Science.gov (United States)

    Yue, Brian; Nizzero, Danielle; Zhang, Chunxiao; van Zyl, Natasha; Ting, Jeannette

    2015-05-01

    Surgical drain tube readings can influence the clinical management of the post-operative patient. The accuracy of these readings has not been documented in the current literature and this experimental study aims to address this paucity. Aliquots (10, 25, 40 and 90 mL) of black tea solution prepared to mimic haemoserous fluid were injected into UnoVac, RedoVac and Jackson-Pratt drain tubes. Nursing and medical staff from a tertiary hospital were asked to estimate drain volumes by direct observation; analysis of variance was performed on the results and significance level was set at 0.05. Doctors and nurses are equally accurate in estimating drain tube volumes. Jackson-Pratt systems were found to be the most accurate for intermediate volumes of 25 and 40 mL. For extreme of volumes (both high and low), all drainage systems were inaccurate. This study suggests that for intermediate volumes (25 and 40 mL), Jackson-Pratt is the drainage system of choice. The accuracy of volume measurement is diminished at the extremes of drain volumes; emptying of drainage systems is recommended to avoid overfilling of drainage systems. © 2014 Royal Australasian College of Surgeons.

  18. Computer-aided, single-specimen controlled bending test for fracture-kinetics measurement in ceramics

    International Nuclear Information System (INIS)

    Borovik, V.G.; Chushko, V.M.; Kovalev, S.P.

    1995-01-01

    Fracture testing of ceramics by using controlled crack growth is proposed to allow study of crack-kinetics behavior under a given loading history. A computer-aided, real-time data acquisition system improves the quality of crack-growth parameters obtained in a simple, single-specimen bend test. Several ceramic materials were tested in the present study: aluminum nitride as a linear-elastic material; and alumina and yttria-stabilized zirconia, both representative of ceramics with microstructure-dependent nonlinear fracture properties. Ambiguities in the crack-growth diagrams are discussed to show the importance of accounting for crack-growth history in correctly describing nonequilibrium fracture behavior

  19. Utility of bronchial lavage fluids for epithelial growth factor receptor mutation assay in lung cancer patients: Comparison between cell pellets, cell blocks and matching tissue specimens

    Science.gov (United States)

    Asaka, Shiho; Yoshizawa, Akihiko; Nakata, Rie; Negishi, Tatsuya; Yamamoto, Hiroshi; Shiina, Takayuki; Shigeto, Shohei; Matsuda, Kazuyuki; Kobayashi, Yukihiro; Honda, Takayuki

    2018-01-01

    The detection of epidermal growth factor receptor (EGFR) mutations is necessary for the selection of suitable patients with non-small cell lung cancer (NSCLC) for treatment with EGFR tyrosine kinase inhibitors. Cytology specimens are known to be suitable for EGFR mutation detection, although tissue specimens should be prioritized; however, there are limited studies that examine the utility of bronchial lavage fluid (BLF) in mutation detection. The purpose of the present study was to investigate the utility of BLF specimens for the detection of EGFR mutations using a conventional quantitative EGFR polymerase chain reaction (PCR) assay. Initially, quantification cycle (Cq) values of cell pellets, cell-free supernatants and cell blocks obtained from three series of 1% EGFR mutation-positive lung cancer cell line samples were compared for mutation detection. In addition, PCR analysis of BLF specimens obtained from 77 consecutive NSCLC patients, detecting EGFR mutations was validated, and these results were compared with those for the corresponding formalin-fixed paraffin-embedded (FFPE) tissue specimens obtained by surgical resection or biopsy of 49 of these patients. The Cq values for mutation detection were significantly lower in the cell pellet group (average, 29.58) compared with the other groups, followed by those in cell-free supernatants (average, 34.15) and in cell blocks (average, 37.12) for all three series (P<0.05). Mutational status was successfully analyzed in 77 BLF specimens, and the results obtained were concordant with those of the 49 matching FFPE tissue specimens. Notably, EGFR mutations were even detected in 10 cytological specimens that contained insufficient tumor cells. EGFR mutation testing with BLF specimens is therefore a useful and reliable method, particularly when sufficient cancer cells are not obtained. PMID:29399190

  20. The role of student surgical interest groups and surgical Olympiads in anatomical and surgical undergraduate training in Russia.

    Science.gov (United States)

    Dydykin, Sergey; Kapitonova, Marina

    2015-01-01

    Traditional department-based surgical interest groups in Russian medical schools are useful tools for student-based selection of specialty training. They also form a nucleus for initiating research activities among undergraduate students. In Russia, the Departments of Topographical Anatomy and Operative Surgery play an important role in initiating student-led research and providing learners with advanced, practical surgical skills. In tandem with department-led activities, student surgical interest groups prepare learners through surgical competitions, known as "Surgical Olympiads," which have been conducted in many Russian centers on a regular basis since 1988. Surgical Olympiads stimulate student interest in the development of surgical skills before graduation and encourage students to choose surgery as their postgraduate specialty. Many of the participants in these surgical Olympiads have become highly qualified specialists in general surgery, orthopedic surgery, neurosurgery, urology, gynecology, and emergency medicine. The present article emphasizes the role of student interest groups and surgical Olympiads in clinical anatomical and surgical undergraduate training in Russia. © 2015 American Association of Anatomists.

  1. Impact of Fibrotic Tissue on Shear Wave Velocity in Thyroid: An Ex Vivo Study with Fresh Thyroid Specimens

    Directory of Open Access Journals (Sweden)

    Takahiro Fukuhara

    2015-01-01

    Full Text Available We sought to elucidate the correlation between shear wave velocity (SWV and fibrosis in thyroid by precisely assessing pathological structures inside 5 × 5 mm2 regions of interest (ROIs of resected specimens, under conditions that excluded physical artifacts. The materials were unselected thyroid and lymph node specimens resected during thyroid surgery. Immediately after surgery, fresh unfixed thyroid and metastatic lymph node specimens were suspended in gel phantoms, and SWV was measured. Upon pathological examination of each specimen, the extent of fibrosis was graded as none, moderate, or severe. A total of 109 specimens were evaluated: 15 normal thyroid, 16 autoimmune thyroiditis, 40 malignant nodules, 19 benign thyroid nodules, and 19 metastatic lymph nodes. When all specimens were classified according to the degree of fibrosis determined by pathological imaging, the mean SWV was 1.49±0.39 m/s for no fibrosis, 2.13±0.66 m/s for moderate fibrosis, and 2.68±0.82 m/s for severe fibrosis. The SWVs of samples with moderate and severe fibrosis were significantly higher than those of samples without fibrosis. The results of this study demonstrate that fibrosis plays an important role in determining stiffness, as measured by SWV in thyroid.

  2. On impact testing of subsize Charpy V-notch type specimens

    International Nuclear Information System (INIS)

    Mikhail, A.S.; Nanstad, R.K.

    1994-01-01

    The potential for using subsize specimens to determine the actual properties of reactor pressure vessel steels is receiving increasing attention for improved vessel condition monitoring that could be beneficial for light-water reactor plant-life extension. This potential is made conditional upon, on the one hand, by the possibility of cutting samples of small volume from the internal surface of the pressure vessel for determination of actual properties of the operating pressure vessel. The plant-life extension will require supplemental surveillance data that cannot be provided by the existing surveillance programs. Testing of subsize specimens manufactured from broken halves of previously tested surveillance Charpy V-notch (CVN) specimens offers an attractive means of extending existing surveillance programs. Using subsize CVN type specimens requires the establishment of a specimen geometry that is adequate to obtain a ductile-to-brittle transition curve similar to that obtained from full-size specimens. This requires the development of a correlation of transition temperature and upper-shelf toughness between subsize and full-size specimens. The present study was conducted under the Heavy-Section Steel Irradiation Program. Different published approaches to the use of subsize specimens were analyzed and five different geometries of subsize specimens were selected for testing and evaluation. The specimens were made from several types of pressure vessel steels with a wide range of yield strengths, transition temperatures, and upper-shelf energies (USEs). Effects of specimen dimensions, including depth, angle, and radius of notch have been studied. The correlation of transition temperature determined from different types of subsize specimens and the full-size specimen is presented. A new procedure for transforming data from subsize specimens was developed and is presented

  3. Improving Surveillance and Prevention of Surgical Site Infection in Pediatric Cardiac Surgery.

    Science.gov (United States)

    Cannon, Melissa; Hersey, Diane; Harrison, Sheilah; Joy, Brian; Naguib, Aymen; Galantowicz, Mark; Simsic, Janet

    2016-03-01

    Postoperative cardiovascular surgical site infections are preventable events that may lead to increased morbidity, mortality, and health care costs. To improve surgical wound surveillance and reduce the incidence of surgical site infections. An institutional review of surgical site infections led to implementation of 8 surveillance and process measures: appropriate preparation the night before surgery and the day of surgery, use of appropriate preparation solution in the operating room, appropriate timing of preoperative antibiotic administration, placement of a photograph of the surgical site in the patient's chart at discharge, sending a photograph of the surgical site to the patient's primary care physician, 30-day follow-up of the surgical site by an advanced nurse practitioner, and placing a photograph of the surgical site obtained on postoperative day 30 in the patient's chart. Mean overall compliance with the 8 measures from March 2013 through February 2014 was 88%. Infections occurred in 10 of 417 total operative cases (2%) in 2012, in 8 of 437 total operative cases (2%) in 2013, and in 7 of 452 total operative cases (1.5%) in 2014. Institution of the surveillance process has resulted in improved identification of suspected surgical site infections via direct rather than indirect measures, accurate identification of all surgical site infections based on definitions of the National Healthcare Safety Network, collaboration with all persons involved, and enhanced communication with patients' family members and referring physicians. ©2016 American Association of Critical-Care Nurses.

  4. Validation of Patient Reported Outcomes Measurement Information System (PROMIS) Computer Adaptive Tests (CATs) in the Surgical Treatment of Lumbar Spinal Stenosis.

    Science.gov (United States)

    Patel, Alpesh A; Dodwad, Shah-Nawaz M; Boody, Barrett S; Bhatt, Surabhi; Savage, Jason W; Hsu, Wellington K; Rothrock, Nan E

    2018-03-19

    Prospective, cohort study. Demonstrate validity of PROMIS physical function, pain interference, and pain behavior computer adaptive tests (CATs) in surgically treated lumbar stenosis patients. There has been increasing attention given to patient reported outcomes associated with spinal interventions. Historical patient outcome measures have inadequate validation, demonstrate floor/ceiling effects, and infrequently used due to time constraints. PROMIS is an adaptive, responsive NIH assessment tool that measures patient-reported health status. 98 consecutive patients were surgically treated for lumbar spinal stenosis and were assessed using PROMIS CATs, ODI, ZCQ and SF-12. Prior lumbar surgery, history of scoliosis, cancer, trauma, or infection were excluded. Completion time, preoperative assessment, 6 week and 3 month postoperative scores were collected. At baseline, 49%, 79%, and 81% of patients had PROMIS PB, PI, and PF scores greater than 1 SD worse than the general population. 50.6% were categorized as severely disabled, crippled, or bed bound by ODI. PROMIS CATs demonstrated convergent validity through moderate to high correlations with legacy measures (r = 0.35-0.73). PROMIS CATs demonstrated known groups validity when stratified by ODI levels of disability. ODI improvements of at least 10 points on average had changes in PROMIS scores in the expected direction (PI = -12.98, PB = -9.74, PF = 7.53). PROMIS CATs demonstrated comparable responsiveness to change when evaluated against legacy measures. PROMIS PB and PI decreased 6.66 and 9.62 and PROMIS PF increased 6.8 points between baseline and 3-months post-op (p validity, known groups validity, and responsiveness for surgically treated patients with lumbar stenosis to detect change over time and are more efficient than legacy instruments. 2.

  5. ASTM international symposium on small specimen test techniques and their applications to pressure vessel annealing and plant life extension

    International Nuclear Information System (INIS)

    Garner, F.A.; Hamilton, M.L.; Heinisch, H.L.; Kumar, A.S.

    1992-01-01

    Miniature sheet-type tensile specimens are currently being used in a variety of radiation damage studies conducted in a number of different reactors. Although these specimens are very small, they have proven successful in addressing issues encountered in both thermal reactors and anticipated fusion reactors. This paper reviews the results of a number of recent studies that illustrate the range of applicability of these small specimens. When combined with other types of specimens and other types of measurements made prior to tensile testing, miniature tensile specimens have been found to serve as very useful tools for application to both fundamental studies and alloy screening studies

  6. The effect of specimen thickness on the experimental and finite ...

    Indian Academy of Sciences (India)

    M. Senthilkumar (Newgen Imaging) 1461 1996 Oct 15 13:05:22

    as a fracture parameter and the J-CTOD relation for the determination of critical ... fracture behaviour of EDD (0·06%C) steel sheets with CT specimens and using ... On the other hand, in the predominantly plane stress region, if the toughness value ..... (iii) Hardness measurement – The plastic zone size and shape is also ...

  7. Bulk specimen X-ray microanalysis of freeze-fractured, freeze-dried tissues in gerontological research

    International Nuclear Information System (INIS)

    Nagy, I.

    1988-01-01

    The rationale for choosing the freeze-fracture freeze-drying (FFFD) method of biological bulk specimen preparation as well as the theoretical and practical problems of this method are treated. FFFD specimens are suitable for quantitative X-ray microanalysis of biologically relevant elements. Although the spatial resolution of this analytical technique is low, the application of properly selected bulk standard crystals as well as the measurement of the intracellular water and dry mass content by means of another method developed in the same laboratory, allow us to obtain useful information about the age-dependent changes of ionic composition in the main intracellular compartments. The paper summarizes the problems with regard to specimen preparation, beam penetration and the quantitative analysis of FFFD specimens. The method has been applied so far mainly for the analysis of intranuclear and intracytoplasmic concentrations of Na, C1 and K in various types of cells and has resulted in a significant contribution to our understanding of the cellular mechanisms of aging. 84 references

  8. Collagen Quantification in Tissue Specimens.

    Science.gov (United States)

    Coentro, João Quintas; Capella-Monsonís, Héctor; Graceffa, Valeria; Wu, Zhuning; Mullen, Anne Maria; Raghunath, Michael; Zeugolis, Dimitrios I

    2017-01-01

    Collagen is the major extracellular protein in mammals. Accurate quantification of collagen is essential in the biomaterials (e.g., reproducible collagen scaffold fabrication), drug discovery (e.g., assessment of collagen in pathophysiologies, such as fibrosis), and tissue engineering (e.g., quantification of cell-synthesized collagen) fields. Although measuring hydroxyproline content is the most widely used method to quantify collagen in biological specimens, the process is very laborious. To this end, the Sircol™ Collagen Assay is widely used due to its inherent simplicity and convenience. However, this method leads to overestimation of collagen content due to the interaction of Sirius red with basic amino acids of non-collagenous proteins. Herein, we describe the addition of an ultrafiltration purification step in the process to accurately determine collagen content in tissues.

  9. Characterization of aerosols produced by surgical procedures

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, H.C.; Muggenburg, B.A.; Lundgren, D.L.; Guilmette, R.A.; Snipes, M.B.; Jones, R.K. [Inhalation Toxicology Research Institute, Albuquerque, NM (United States); Turner, R.S. [Lovelace Health Systems, Albuquerque, NM (United States)

    1994-07-01

    In many surgeries, especially orthopedic procedures, power tools such as saws and drills are used. These tools may produce aerosolized blood and other biological material from bone and soft tissues. Surgical lasers and electrocautery tools can also produce aerosols when tissues are vaporized and condensed. Studies have been reported in the literature concerning production of aerosols during surgery, and some of these aerosols may contain infectious material. Garden et al. (1988) reported the presence of papilloma virus DNA in the fumes produced from laser surgery, but the infectivity of the aerosol was not assessed. Moon and Nininger (1989) measured the size distribution and production rate of emissions from laser surgery and found that particles were generally less than 0.5 {mu}m diameter. More recently there has been concern expressed over the production of aerosolized blood during surgical procedures that require power tools. In an in vitro study, the production of an aerosol containing the human immunodeficiency virus (HIV) was reported when power tools were used to cut tissues with blood infected with HIV. Another study measured the size distribution of blood aerosols produced by surgical power tools and found blood-containing particles in a number of size ranges. Health care workers are anxious and concerned about whether surgically produced aerosols are inspirable and can contain viable pathogens such as HIV. Other pathogens such as hepatitis B virus (HBV) are also of concern. The Occupational Safety and Health funded a project at the National Institute for Inhalation Toxicology Research Institute to assess the extent of aerosolization of blood and other tissues during surgical procedures. This document reports details of the experimental and sampling approach, methods, analyses, and results on potential production of blood-associated aerosols from surgical procedures in the laboratory and in the hospital surgical suite.

  10. Pneumatic-type surgical robot end-effector for laparoscopic surgical-operation-by-wire.

    Science.gov (United States)

    Lee, Chiwon; Park, Woo Jung; Kim, Myungjoon; Noh, Seungwoo; Yoon, Chiyul; Lee, Choonghee; Kim, Youdan; Kim, Hyeon Hoe; Kim, Hee Chan; Kim, Sungwan

    2014-09-05

    Although minimally invasive surgery (MIS) affords several advantages compared to conventional open surgery, robotic MIS systems still have many limitations. One of the limitations is the non-uniform gripping force due to mechanical strings of the existing systems. To overcome this limitation, a surgical instrument with a pneumatic gripping system consisting of a compressor, catheter balloon, micro motor, and other parts is developed. This study aims to implement a surgical instrument with a pneumatic gripping system and pitching/yawing joints using micro motors and without mechanical strings based on the surgical-operation-by-wire (SOBW) concept. A 6-axis external arm for increasing degrees of freedom (DOFs) is integrated with the surgical instrument using LabVIEW® for laparoscopic procedures. The gripping force is measured over a wide range of pressures and compared with the simulated ideal step function. Furthermore, a kinematic analysis is conducted. To validate and evaluate the system's clinical applicability, a simple peg task experiment and workspace identification experiment are performed with five novice volunteers using the fundamentals of laparoscopic surgery (FLS) board kit. The master interface of the proposed system employs the hands-on-throttle-and-stick (HOTAS) controller used in aerospace engineering. To develop an improved HOTAS (iHOTAS) controller, 6-axis force/torque sensor was integrated in the special housing. The mean gripping force (after 1,000 repetitions) at a pressure of 0.3 MPa was measured to be 5.8 N. The reaction time was found to be 0.4 s, which is almost real-time. All novice volunteers could complete the simple peg task within a mean time of 176 s, and none of them exceeded the 300 s cut-off time. The system's workspace was calculated to be 11,157.0 cm3. The proposed pneumatic gripping system provides a force consistent with that of other robotic MIS systems. It provides near real-time control. It is more durable than the

  11. Benchmarking of World Health Organization surgical safety checklist

    International Nuclear Information System (INIS)

    Messahel, Farouk M.; AlQahtani, Ali S.

    2009-01-01

    To compare the quality of our services with the World Health Organization (WHO) surgical safety recommendations as a reference, to improve our services if they fall short of that of the WHO, and to publish our additional standards, so that they may be included in future revision of WHO checklist. We conducted this study on 15th July 2008 at the Armed Forces Hospital, Wadi Al-Dawasir, Kingdom of Saudi Arabia. We compared each WHO safety standard item with its corresponding standard in our checklist. There were 4 possibilities for the comparison: that our performance meet, was less than or exceeded the quality-of-care measures in the WHO checklist, or that there are additional safety measures in either checklist that need to be considered by each party. Since its introduction in 1997, our checklist was applied to 11828 patients and resulted in error-free outcomes. Benchmarking proved that our surgical safety performance does not only match the standards of the WHO surgical safety checklist, but also exceeds it in other safety areas (for example measures to prevent perioperative hypothermia and venous thromboembolism). Benchmarking is a continuous quality improvement process aimed at providing the best available at the time in healthcare, and we recommend its adoption by healthcare providers. The WHO surgical safety checklist is a bold step in the right direction towards safer surgical outcomes. Feedback from other medical establishments should be encouraged. (author)

  12. A non-destructive DNA sampling technique for herbarium specimens.

    Science.gov (United States)

    Shepherd, Lara D

    2017-01-01

    Herbarium specimens are an important source of DNA for plant research but current sampling methods require the removal of material for DNA extraction. This is undesirable for irreplaceable specimens such as rare species or type material. Here I present the first non-destructive sampling method for extracting DNA from herbarium specimens. DNA was successfully retrieved from robust leaves and/or stems of herbarium specimens up to 73 years old.

  13. Miniature tensile test specimens for fusion reactor irradiation studies

    International Nuclear Information System (INIS)

    Klueh, R.L.

    1985-01-01

    Three miniature sheet-type tensile specimens and a miniature rod-type specimen are being used to determine irradiated tensile properties for alloy development for fusion reactors. The tensile properties of type 316 stainless steel were determined with these different specimens, and the results were compared. Reasonably good agreement was observed. However, there were differences that led to recommendations on which specimens are preferred. 4 references, 9 figures, 6 tables

  14. 10 CFR 26.165 - Testing split specimens and retesting single specimens.

    Science.gov (United States)

    2010-01-01

    ... (c), as applicable. If the specimen in Bottle A is free of any evidence of drugs or drug metabolites... suitable inquiry conducted under the provisions of § 26.63 or to any other inquiry or investigation... records must be provided to personnel conducting reviews, inquiries into allegations, or audits under the...

  15. The influence of microstructure on surface strain distributions in a nickel micro-tension specimen

    International Nuclear Information System (INIS)

    Turner, T J; Shade, P A; Schuren, J C; Groeber, M A

    2013-01-01

    This work presents an integrated experimental and modeling approach for examining the deformation of a pure nickel polycrystal utilizing micro-mechanical testing and a crystal-based elasto-viscoplastic finite-element model (CPFEM). The objective is to study the influence of microstructure on the heterogeneous deformation in polycrystalline materials, and to utilize a modeling framework to explore aspects of the deformation that are difficult or impossible to measure experimentally. To accomplish this, a micro-tension specimen containing 259 grains was created from a pure nickel foil material and deformed in uniaxial tension. After the deformation, the specimen was destructively serial sectioned in concert with electron back scattering diffraction, and these data were used to instantiate a CPFEM simulation. The material parameters in the CPFEM model were calibrated by matching the experimental macroscopic stress-strain response of the micro-tension specimen, and then the simulation results were compared with experimental surface deformations measured with digital image correlation. After validating the simulation results by comparing measured and predicted surface strain distributions, a parametric study of the influence of both crystallographic texture and grain morphology is presented to better understand the influence of microstructure on the development of heterogeneous deformation in the pure nickel polycrystalline material. (paper)

  16. Surgical pathology report defects: a College of American Pathologists Q-Probes study of 73 institutions.

    Science.gov (United States)

    Volmar, Keith E; Idowu, Michael O; Hunt, Jennifer L; Souers, Rhona J; Meier, Frederick A; Nakhleh, Raouf E

    2014-05-01

    The rate of surgical pathology report defects is an indicator of quality and it affects clinician satisfaction. To establish benchmarks for defect rates and defect fractions through a large, multi-institutional prospective application of standard taxonomy. Participants in a 2011 Q-Probes study of the College of American Pathologists prospectively reviewed all surgical pathology reports that underwent changes to correct defects and reported details regarding the defects. Seventy-three institutions reported 1688 report defects discovered in 360,218 accessioned cases, for an aggregate defect rate of 4.7 per 1000 cases. Median institutional defect rate was 5.7 per 1000 (10th to 90th percentile range, 13.5-0.9). Defect rates were higher in institutions with a pathology training program (8.5 versus 5.0 per 1000, P = .01) and when a set percentage of cases were reviewed after sign-out (median, 6.7 versus 3.8 per 1000, P = .10). Defect types were as follows: 14.6% misinterpretations, 13.3% misidentifications, 13.7% specimen defects, and 58.4% other report defects. Overall, defects were most often detected by pathologists (47.4%), followed by clinicians (22.0%). Misinterpretations and specimen defects were most often detected by pathologists (73.5% and 82.7% respectively, P benchmarking data on report defects and defect fractions using standardized taxonomy.

  17. Wrong-Site Surgery, Retained Surgical Items, and Surgical Fires : A Systematic Review of Surgical Never Events.

    Science.gov (United States)

    Hempel, Susanne; Maggard-Gibbons, Melinda; Nguyen, David K; Dawes, Aaron J; Miake-Lye, Isomi; Beroes, Jessica M; Booth, Marika J; Miles, Jeremy N V; Shanman, Roberta; Shekelle, Paul G

    2015-08-01

    Serious, preventable surgical events, termed never events, continue to occur despite considerable patient safety efforts. To examine the incidence and root causes of and interventions to prevent wrong-site surgery, retained surgical items, and surgical fires in the era after the implementation of the Universal Protocol in 2004. We searched 9 electronic databases for entries from 2004 through June 30, 2014, screened references, and consulted experts. Two independent reviewers identified relevant publications in June 2014. One reviewer used a standardized form to extract data and a second reviewer checked the data. Strength of evidence was established by the review team. Data extraction was completed in January 2015. Incidence of wrong-site surgery, retained surgical items, and surgical fires. We found 138 empirical studies that met our inclusion criteria. Incidence estimates for wrong-site surgery in US settings varied by data source and procedure (median estimate, 0.09 events per 10,000 surgical procedures). The median estimate for retained surgical items was 1.32 events per 10,000 procedures, but estimates varied by item and procedure. The per-procedure surgical fire incidence is unknown. A frequently reported root cause was inadequate communication. Methodologic challenges associated with investigating changes in rare events limit the conclusions of 78 intervention evaluations. Limited evidence supported the Universal Protocol (5 studies), education (4 studies), and team training (4 studies) interventions to prevent wrong-site surgery. Limited evidence exists to prevent retained surgical items by using data-matrix-coded sponge-counting systems (5 pertinent studies). Evidence for preventing surgical fires was insufficient, and intervention effects were not estimable. Current estimates for wrong-site surgery and retained surgical items are 1 event per 100,000 and 1 event per 10,000 procedures, respectively, but the precision is uncertain, and the per

  18. Development and validation of a computational model of the knee joint for the evaluation of surgical treatments for osteoarthritis.

    Science.gov (United States)

    Mootanah, R; Imhauser, C W; Reisse, F; Carpanen, D; Walker, R W; Koff, M F; Lenhoff, M W; Rozbruch, S R; Fragomen, A T; Dewan, Z; Kirane, Y M; Cheah, K; Dowell, J K; Hillstrom, H J

    2014-01-01

    A three-dimensional (3D) knee joint computational model was developed and validated to predict knee joint contact forces and pressures for different degrees of malalignment. A 3D computational knee model was created from high-resolution radiological images to emulate passive sagittal rotation (full-extension to 65°-flexion) and weight acceptance. A cadaveric knee mounted on a six-degree-of-freedom robot was subjected to matching boundary and loading conditions. A ligament-tuning process minimised kinematic differences between the robotically loaded cadaver specimen and the finite element (FE) model. The model was validated by measured intra-articular force and pressure measurements. Percent full scale error between FE-predicted and in vitro-measured values in the medial and lateral compartments were 6.67% and 5.94%, respectively, for normalised peak pressure values, and 7.56% and 4.48%, respectively, for normalised force values. The knee model can accurately predict normalised intra-articular pressure and forces for different loading conditions and could be further developed for subject-specific surgical planning.

  19. 3D Printed Models of Cleft Palate Pathology for Surgical Education.

    Science.gov (United States)

    Lioufas, Peter A; Quayle, Michelle R; Leong, James C; McMenamin, Paul G

    2016-09-01

    To explore the potential viability and limitations of 3D printed models of children with cleft palate deformity. The advantages of 3D printed replicas of normal anatomical specimens have previously been described. The creation of 3D prints displaying patient-specific anatomical pathology for surgical planning and interventions is an emerging field. Here we explored the possibility of taking rare pediatric radiographic data sets to create 3D prints for surgical education. Magnetic resonance imaging data of 2 children (8 and 14 months) were segmented, colored, and anonymized, and stereolothographic files were prepared for 3D printing on either multicolor plastic or powder 3D printers and multimaterial 3D printers. Two models were deemed of sufficient quality and anatomical accuracy to print unamended. One data set was further manipulated digitally to artificially extend the length of the cleft. Thus, 3 models were printed: 1 incomplete soft-palate deformity, 1 incomplete anterior palate deformity, and 1 complete cleft palate. All had cleft lip deformity. The single-material 3D prints are of sufficient quality to accurately identify the nature and extent of the deformities. Multimaterial prints were subsequently created, which could be valuable in surgical training. Improvements in the quality and resolution of radiographic imaging combined with the advent of multicolor multiproperty printer technology will make it feasible in the near future to print 3D replicas in materials that mimic the mechanical properties and color of live human tissue making them potentially suitable for surgical training.

  20. Surgical anatomy and histology of the levator palpebrae superioris muscle for blepharoptosis correction

    Directory of Open Access Journals (Sweden)

    Đorđević Boban

    2013-01-01

    Full Text Available Background/Aim. The detailed knowledge of the architecture of the upper eyelid is very important in numerous upper eyelid corrective surgeries. The article deals with the detailed anatomy of the major components of the upper lid, which are commonly seen in surgical practice. Methods. This study was conducted on 19 human cadavers (12 adults and 7 infants without pathologic changes in the orbital region and eyelids. Anatomic microdissection of the contents of the orbita was performed bilaterally on 12 orbits from 6 unfixed cadavers (3 male and 3 female. Micromorphologic investigations of the orbital tissue were performed on 8 en bloc excised and formalin-fixed orbits of infant cadavers. Specimens were fixed according to the Duvernoy method. An intra-arterial injection of 5% mixture of melt formalin and black ink was administered into the carotid arterial system. Using routine fixation, decalcination, dehydration, illumination, impregnation and molding procedures in paraplast, specimens were prepared for cross-sections. Results. The measurement of the muscle length and diameter in situ in 6 nonfixed cadavers (12 orbits showed an average length of the levator palpbrae superioris (LPS muscle body of the 42.0 ± 1.41 mm on the right, and 40.3 ± 1.63 mm on the left side. In all the cases, the LPS had blood supply from 4 different arterial systems: the lacrimal, supratrochlear, and supraorbital artery and muscle branches of the ophthalmic artery. The LPS muscle in all the specimens was supplied by the superior medial branch of the oculomotor nerve. The connective tissue associated with the LPS muscle contains two transverse ligaments: the superior (Whitnall’s and intermuscular transverse ligaments (ITL. The orbital septum in all the specimens originated from the arcus marginalis of the frontal bone, and consisted of two layers - the superficial and the inner layer. In addition, a detailed histological analysis revealed that the upper eyelid

  1. Surgical anatomy and histology of the levator palpebrae superioris muscle for blepharoptosis correction.

    Science.gov (United States)

    Djordjević, Boban; Novaković, Marijan; Milisavljević, Milan; Milićević, Sasa; Maliković, Aleksandar

    2013-12-01

    The detailed knowledge of the architecture of the upper eyelid is very important in numerous upper eyelid corrective surgeries. The article deals with the detailed anatomy of the major components of the upper lid, which are commonly seen in surgical practice. This study was conducted on 19 human cadavers (12 adults and 7 infants) without pathologic changes in the orbital region and eyelids. Anatomic microdissection of the contents of the orbita was performed bilaterally on 12 orbits from 6 unfixed cadavers (3 male and 3 female). Micromorphologic investigations of the orbital tissue were performed on 8 en bloc excised and formalin-fixed orbits of infant cadavers. Specimens were fixed according to the Duvernoy method. An intra-arterial injection of 5% mixture of melt formalin and black ink was administered into the carotid arterial system. Using routine fixation, decalcination, dehydration, illumination, impregnation and molding procedures in paraplast, specimens were prepared for cross-sections. The measurement of the muscle length and diameter in situ in 6 nonfixed cadavers (12 orbits) showed an average length of the levator palpbrae superioris (LPS) muscle body of the 42.0 +/- 1.41 mm on the right, and 40.3 +/- 1.63 mm on the left side. In all the cases, the LPS had blood supply from 4 different arterial systems: the lacrimal, supratrochlear, and supraorbital artery and muscle branches of the ophthalmic artery. The LPS muscle in all the specimens was supplied by the superior medial branch of the oculomotor nerve. The connective tissue associated with the LPS muscle contains two transverse ligaments: the superior (Whitnall's) and intermuscular transverse ligaments (ITL). The orbital septum in all the specimens originated from the arcus marginalis of the frontal bone, and consisted of two layers--the superficial and the inner layer. In addition, a detailed histological analysis revealed that the upper eyelid's crease was formed by the conjoined fascia including the

  2. Mastoidectomy: anatomical parameters x surgical difficulty

    Directory of Open Access Journals (Sweden)

    Pereira Júnior, Anastácio Rodrigues

    2012-01-01

    Full Text Available Introduction: The lowered temporal meninges and/ or anterior sigmoid sinus are contiditions that can determine surgical difficulties in performing mastoidectomy. Objective: To correlate in the tomography the extent of the prolapse of the sigmoid sinus and of temporal meninges with the surgical difficulty in the mastoidectomy. Method: The tomographic measurements of prolapse sigmoid and of temporal meninges were correlated with the presence or non-presence of the surgical difficulty observed during the mastoidectomy procedure in patients with ostomatoiditis chronic (n=30. Form of study: Contemporary cohort transverse. Results: In 10 patients were observed surgical difficulty distributed as: due to prolapse of the sigmoid sinus (n = 2 or temporal meninges prolapse (n = 7 or both (n = 1. In patients in which the surgical difficulty was due to sigmoid sinus prolapse, the tomography distance of the anterior border of the sigmoid sinus to posterior wall of external auditory canal was lower than 9 mm. In patients in which surgical difficulty was due to temporal meninges prolapse, the tomographic distance to the upper plane of the petrous bone was 7 mm. Conclusion: The computerized tomography distance between the temporal meninges and the upper plane of the petrous bone 7 mm and the distance of the anterior border of the sigmoid sinus to posterior wall of external auditory canal was lower than 9 mm are predictive to the surgical difficulties to perform mastoidectomy.

  3. Fractography evaluation of impact and tensile specimens from the HFBR [High Flux Beam Reactor

    International Nuclear Information System (INIS)

    Czajkowski, C.J.

    1989-10-01

    The Materials Technology Group of the Department of Nuclear Energy (DNE) at Brookhaven National Laboratory (BNL) has performed a fractographic examination of neutron irradiated and unirradiated tensile and Charpy ''V'' notch specimens. The evaluation was carried out using a scanning electron microscope (SEM) to evaluate the fracture mode. Photomicrographs were then evaluated to determine the extent of ductility present on the fracture surfaces of the unirradiated specimens. Ductility area measurements ranged from 4.6--9.5% on typical photomicrographs examined. 12 figs

  4. Handling of biological specimens for electron microscopy

    International Nuclear Information System (INIS)

    Bullock, G.

    1987-01-01

    There are many different aspects of specimen preparation procedure which need to be considered in order to achieve good results. Whether using the scanning or transmission microscope, the initial handling procedures are very similar and are selected for the information required. Handling procedures and techniques described are: structural preservation; immuno-and histo-chemistry; x-ray microanalysis and autoradiography; dehydration and embedding; mounting and coating specimens for scanning electron microscopy; and sectioning of resin embedded material. With attention to detail and careful choice of the best available technique, excellent results should be obtainable whatever the specimen. 6 refs

  5. Surgical Instrument Sets for Special Operations Expeditionary Surgical Teams.

    Science.gov (United States)

    Hale, Diane F; Sexton, Justin C; Benavides, Linda C; Benavides, Jerry M; Lundy, Jonathan B

    The deployment of surgical assets has been driven by mission demands throughout years of military operations in Iraq and Afghanistan. The transition to the highly expeditious Golden Hour Offset Surgical Transport Team (GHOST- T) now offers highly mobile surgical assets in nontraditional operating rooms; the content of the surgical instrument sets has also transformed to accommodate this change. The 102nd Forward Surgical Team (FST) was attached to Special Operations assigned to southern Afghanistan from June 2015 to March 2016. The focus was to decrease overall size and weight of FST instrument sets without decreasing surgical capability of the GHOST-T. Each instrument set was evaluated and modified to include essential instruments to perform damage control surgery. The overall number of main instrument sets was decreased from eight to four; simplified augmentation sets have been added, which expand the capabilities of any main set. The overall size was decreased by 40% and overall weight decreased by 58%. The cardiothoracic, thoracotomy, and emergency thoracotomy trays were condensed to thoracic set. The orthopedic and amputation sets were replaced with an augmentation set of a prepackaged orthopedic external fixator set). An augmentation set to the major or minor basic sets, specifically for vascular injuries, was created. Through the reorganization of conventional FST surgical instrument sets to maintain damage control capabilities and mobility, the 102nd GHOST-T reduced surgical equipment volume and weight, providing a lesson learned for future surgical teams operating in austere environments. 2017.

  6. Elastic-plastic analysis of the SS-3 tensile specimen

    International Nuclear Information System (INIS)

    Majumdar, S.

    1998-01-01

    Tensile tests of most irradiated specimens of vanadium alloys are conducted using the miniature SS-3 specimen which is not ASTM approved. Detailed elastic-plastic finite element analysis of the specimen was conducted to show that, as long as the ultimate to yield strength ratio is less than or equal to 1.25 (which is satisfied by many irradiated materials), the stress-plastic strain curve obtained by using such a specimen is representative of the true material behavior

  7. Progress Report on Alloy 617 Notched Specimen Testing

    Energy Technology Data Exchange (ETDEWEB)

    McMurtrey, Michael David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Wright, Richard Neil [Idaho National Lab. (INL), Idaho Falls, ID (United States); Lillo, Thomas Martin [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-08-01

    Creep behavior of Alloy 617 has been extensively characterized to support the development of a draft Code Case to qualify Alloy 617 in Section III division 5 of the ASME Boiler and Pressure Vessel Code. This will allow use of Alloy 617 in construction of nuclear reactor components at elevated temperatures and longer periods of time (up to 950°C and 100,000 hours). Prior to actual use, additional concerns not considered in the ASME code need to be addressed. Code Cases are based largely on uniaxial testing of smooth gage specimens. In service conditions, components will generally be under multi axial loading. There is also the concern of the behavior at discontinuities, such as threaded components. To address the concerns of multi axial creep behavior and at geometric discontinuities, notched specimens have been designed to create conditions representative of the states that service components experience. Two general notch geometries have been used for these series of tests: U notch and V notch specimens. The notches produce a tri axial stress state, though not uniform across the specimen. Characterization of the creep behavior of the U notch specimens and the creep rupture behavior of the V notch specimens provides a good approximation of the behavior expected of actual components. Preliminary testing and analysis have been completed and are reported in this document. This includes results from V notch specimens tested at 900°C and 800°C. Failure occurred in the smooth gage section of the specimen rather than at the root of the notch, though some damage was present at the root of the notch, where initial stress was highest. This indicates notch strengthening behavior in this material at these temperatures.

  8. Cluster analysis in soft X-ray spectromicroscopy: Finding the patterns in complex specimens

    Energy Technology Data Exchange (ETDEWEB)

    Lerotic, M. [Department of Physics and Astronomy, State University of New York at Stony Brook, Stony Brook, NY 11794-3800 (United States)]. E-mail: lerotic@xray1.physics.sunysb.edu; Jacobsen, C. [Department of Physics and Astronomy, State University of New York at Stony Brook, Stony Brook, NY 11794-3800 (United States); Gillow, J.B. [Environmental Sciences Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Francis, A.J. [Environmental Sciences Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); Wirick, S. [Department of Physics and Astronomy, State University of New York at Stony Brook, Stony Brook, NY 11794-3800 (United States); Vogt, S. [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States); Maser, J. [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2005-06-15

    Soft X-ray spectromicroscopy provides spectral data on the chemical speciation of light elements at sub-100 nanometer spatial resolution. If all chemical species in a specimen are known and separately characterized, existing approaches can be used to measure the concentration of each component at each pixel. In other situations such as in biology or environmental science, this approach may not be possible. We have previously described [M. Lerotic, C. Jacobsen, T. Schaefer, S. Vogt, Ultramicroscopy 100 (1-2) (2004) 35] the use of principle component analysis (PCA) to orthogonalize and noise-filter spectromicroscopy data, and cluster analysis (Canada) to classify the analyzed data and obtain thickness maps of representative spectra. We describe here an extension of that work employing an angle distance measure; this measure provides better classification based on spectral signatures alone in specimens with significant thickness variations. The method is illustrated using simulated data, and also to examine sporulation in the bacterium Clostridium sp.

  9. Some recent innovations in small specimen testing

    International Nuclear Information System (INIS)

    Odette, G.R.; He, M.; Gragg, D.; Klingensmith, D.; Lucas, G.E.

    2002-01-01

    New innovative small specimen test techniques are described. Finite element simulations show that combinations of cone indentation pile-up geometry and load-penetration depth relations can be used to determine both the yield stress and strain-hardening behavior of a material. Techniques for pre-cracking and testing sub-miniaturized fracture toughness bend bars, with dimensions of 1.65x1.65x9 mm 3 , or less, are described. The corresponding toughness-temperature curves have a very steep transition slope, primarily due to rapid loss of constraint, which has advantages in some experiments to characterize the effects of specified irradiation variables. As one example of using composite specimens, an approach to evaluating helium effects is proposed, involving diffusion bonding small wires of a 54 Fe-based ferritic-martensitic alloy to a surrounding fracture specimen composed of an elemental Fe-based alloy. Finally, we briefly outline some potential approaches to multipurpose specimens and test automation

  10. Blood specimen labelling errors: Implications for nephrology nursing practice.

    Science.gov (United States)

    Duteau, Jennifer

    2014-01-01

    Patient safety is the foundation of high-quality health care, as recognized both nationally and worldwide. Patient blood specimen identification is critical in ensuring the delivery of safe and appropriate care. The practice of nephrology nursing involves frequent patient blood specimen withdrawals to treat and monitor kidney disease. A critical review of the literature reveals that incorrect patient identification is one of the major causes of blood specimen labelling errors. Misidentified samples create a serious risk to patient safety leading to multiple specimen withdrawals, delay in diagnosis, misdiagnosis, incorrect treatment, transfusion reactions, increased length of stay and other negative patient outcomes. Barcode technology has been identified as a preferred method for positive patient identification leading to a definitive decrease in blood specimen labelling errors by as much as 83% (Askeland, et al., 2008). The use of a root cause analysis followed by an action plan is one approach to decreasing the occurrence of blood specimen labelling errors. This article will present a review of the evidence-based literature surrounding blood specimen labelling errors, followed by author recommendations for completing a root cause analysis and action plan. A failure modes and effects analysis (FMEA) will be presented as one method to determine root cause, followed by the Ottawa Model of Research Use (OMRU) as a framework for implementation of strategies to reduce blood specimen labelling errors.

  11. Study of Biological Pigments by Single Specimen Derivative Spectrophotometry

    Science.gov (United States)

    Goldstein, Jack M.

    1970-01-01

    The single specimen derivative (SSD) method provides an absolute absorption spectrum of a substance in the absence of a suitable reference. Both a reference and a measuring monochromatic beam pass through a single sample, and the specimen itself acts as its own reference. The two monochromatic beams maintain a fixed wavelength difference upon scanning, and the difference in absorbance of the two beams is determined. Thus, the resulting spectrum represents the first derivative of the conventional type absorption spectrum. Tissues and cell fractions have been examined at room and liquid N2 temperature and chromophoric molecules such as the mitochondrial cytochromes and blood pigments have been detectable in low concentrations. In the case of isolated cellular components, the observed effects of substrates and inhibitors confirm similar studies by conventional spectrophotometry. The extension of the SSD concept to the microscopic level has permitted the study of the tissue compartmentalization and function of cytochromes and other pigments within layered tissue. PMID:4392452

  12. Miniature specimen technology for postirradiation fatigue crack growth testing

    International Nuclear Information System (INIS)

    Mervyn, D.A.; Ermi, A.M.

    1979-01-01

    Current magnetic fusion reactor design concepts require that the fatigue behavior of candidate first wall materials be characterized. Fatigue crack growth may, in fact, be the design limiting factor in these cyclic reactor concepts given the inevitable presence of crack-like flaws in fabricated sheet structures. Miniature specimen technology has been developed to provide the large data base necessary to characterize irradiation effects on the fatigue crack growth behavior. An electrical potential method of measuring crack growth rates is employed on miniature center-cracked-tension specimens (1.27 cm x 2.54 cm x 0.061 cm). Results of a baseline study on 20% cold-worked 316 stainless steel, which was tested in an in-cell prototypic fatigue machine, are presented. The miniature fatigue machine is designed for low cost, on-line, real time testing of irradiated fusion candidate alloys. It will enable large scale characterization and development of candidate first wall alloys

  13. Surgical orthodontics.

    Science.gov (United States)

    Strohl, Alexis M; Vitkus, Lauren

    2017-08-01

    The article reviews some commonly used orthodontic treatments as well as new strategies to assist in the correction of malocclusion. Many techniques are used in conjunction with surgical intervention and are a necessary compliment to orthognathic surgery. Basic knowledge of these practices will aid in the surgeon's ability to adequately treat the patient. Many orthodontists and surgeons are eliminating presurgical orthodontics to adopt a strategy of 'surgery first' orthodontics in orthognathic surgery. This has the benefit of immediate improvement in facial aesthetics and shorter treatment times. The advent of virtual surgical planning has helped facilitate the development of this new paradigm by making surgical planning faster and easier. Furthermore, using intraoperative surgical navigation is improving overall precision and outcomes. A variety of surgical and nonsurgical treatments may be employed in the treatment of malocclusion. It is important to be familiar with all options available and tailor the patient's treatment plan accordingly. Surgery-first orthodontics, intraoperative surgical navigation, virtual surgical planning, and 3D printing are evolving new techniques that are producing shorter treatment times and subsequently improving patient satisfaction without sacrificing long-term stability.

  14. Radical prostatectomy and positive surgical margins: tumor volume and Gleason score predicts cancer outcome

    International Nuclear Information System (INIS)

    La Roca, Ricardo L.R. Felts de; Fonseca, Francisco Paula da; Cunha, Isabela Werneck da; Bezerra, Stephania Martins

    2013-01-01

    Introduction: positive surgical margins (PSMs) are common adverse factors to predict the outcome of a patient submitted to radical prostatectomy (PR). However, not all of these men will follow with biochemical (BCR) or clinical (CR) recurrence. Relationship between PSMs with these recurrent events has to be correlated with other clinicopathological findings in order to recognize more aggressive tumors in order to recommend complementary treatment to these selected patients. Materials and methods: we retrospectively reviewed the outcome of 228 patients submitted to open retropubic RP between March 1991 and June 2008, where 161 had and 67 did not have PSMs. Minimum follow-up time was considered 2 years after surgery. BCR was considered when PSA ≥ 0.2 ng/ml. CR was determined when clinical evidence of tumor appeared. Chi-square test was used to correlate clinical and pathologic variables with PSMs. The estimated 5-year risk of BCR and CR in presence of PSMs was determined using the Kaplan-Meier method and compared to log-rank tests. Results: from the total of 228 patients, 161 (71%) had PSMs, while 67 (29%) had negative surgical margins (NSMs). Prostatic circumferential margin was the most common (43.4%) site. Univariate analysis showed statistically significant (p < 0.001) associations between the presence of PSMs and BCR, but not with CR (p = 0.06). Among 161 patients with PSMs, 61 (37.8%) presented BCR, while 100 (62.8%) did not. Predicting progression-free survival for 5 years, BCR was correlated with pathological stage; Gleason score; pre-treatment PSA; tumor volume in specimen; capsular and perineural invasion; presence and number of PSMs. RC correlated only with angiolymphatic invasion and Gleason score. Considering univariate analyses the clinicopathological factors predicting BCR for 5 years, results statistically significant links with prostate weight; pre-treatment PSA; Gleason score; pathological stage; tumor volume; PSMs; capsular and perineural

  15. Radical prostatectomy and positive surgical margins: tumor volume and Gleason score predicts cancer outcome

    Energy Technology Data Exchange (ETDEWEB)

    La Roca, Ricardo L.R. Felts de, E-mail: Ricardo@delarocaurologia.com.br [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil); Fonseca, Francisco Paula da, E-mail: fpf@uol.com.br [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Divisao de Urologia. Dept. de Cirurgia Pelvica; Cunha, Isabela Werneck da; Bezerra, Stephania Martins, E-mail: iwerneck@gmail.com, E-mail: stephaniab@gmail.com [Hospital do Cancer A.C. Camargo, Sao Paulo, SP (Brazil). Dept. de Patologia

    2013-07-01

    Introduction: positive surgical margins (PSMs) are common adverse factors to predict the outcome of a patient submitted to radical prostatectomy (PR). However, not all of these men will follow with biochemical (BCR) or clinical (CR) recurrence. Relationship between PSMs with these recurrent events has to be correlated with other clinicopathological findings in order to recognize more aggressive tumors in order to recommend complementary treatment to these selected patients. Materials and methods: we retrospectively reviewed the outcome of 228 patients submitted to open retropubic RP between March 1991 and June 2008, where 161 had and 67 did not have PSMs. Minimum follow-up time was considered 2 years after surgery. BCR was considered when PSA {>=} 0.2 ng/ml. CR was determined when clinical evidence of tumor appeared. Chi-square test was used to correlate clinical and pathologic variables with PSMs. The estimated 5-year risk of BCR and CR in presence of PSMs was determined using the Kaplan-Meier method and compared to log-rank tests. Results: from the total of 228 patients, 161 (71%) had PSMs, while 67 (29%) had negative surgical margins (NSMs). Prostatic circumferential margin was the most common (43.4%) site. Univariate analysis showed statistically significant (p < 0.001) associations between the presence of PSMs and BCR, but not with CR (p = 0.06). Among 161 patients with PSMs, 61 (37.8%) presented BCR, while 100 (62.8%) did not. Predicting progression-free survival for 5 years, BCR was correlated with pathological stage; Gleason score; pre-treatment PSA; tumor volume in specimen; capsular and perineural invasion; presence and number of PSMs. RC correlated only with angiolymphatic invasion and Gleason score. Considering univariate analyses the clinicopathological factors predicting BCR for 5 years, results statistically significant links with prostate weight; pre-treatment PSA; Gleason score; pathological stage; tumor volume; PSMs; capsular and perineural

  16. The Effect of Specimen Size on the Results of Concrete Adiabatic Temperature Rise Test with Commercially Available Equipment

    Directory of Open Access Journals (Sweden)

    Byung Jae Lee

    2014-12-01

    Full Text Available In this study, adiabatic temperature rise tests depending on binder type and adiabatic specimen volume were performed, and the maximum adiabatic temperature rises and the reaction factors for each mix proportion were analyzed and suggested. The results indicated that the early strength low heat blended cement mixture had the lowest maximum adiabatic temperature rise (Q∞ and the ternary blended cement mixture had the lowest reaction factor (r. Also, Q and r varied depending on the adiabatic specimen volume even when the tests were conducted with a calorimeter, which satisfies the recommendations for adiabatic conditions. Test results show a correlation: the measurements from the 50 L specimens were consistently higher than those from the 6 L specimens. However, the Q∞ and r values of the 30 L specimen were similar to those of the 50 L specimen. Based on the above correlation, the adiabatic temperature rise of the 50 L specimen could be predicted using the results of the 6 L and 30 L specimens. Therefore, it is thought that this correlation can be used for on-site concrete quality control and basic research.

  17. The Effect of Specimen Size on the Results of Concrete Adiabatic Temperature Rise Test with Commercially Available Equipment.

    Science.gov (United States)

    Lee, Byung Jae; Bang, Jin Wook; Shin, Kyung Joon; Kim, Yun Yong

    2014-12-08

    In this study, adiabatic temperature rise tests depending on binder type and adiabatic specimen volume were performed, and the maximum adiabatic temperature rises and the reaction factors for each mix proportion were analyzed and suggested. The results indicated that the early strength low heat blended cement mixture had the lowest maximum adiabatic temperature rise ( Q ∞ ) and the ternary blended cement mixture had the lowest reaction factor ( r ). Also, Q and r varied depending on the adiabatic specimen volume even when the tests were conducted with a calorimeter, which satisfies the recommendations for adiabatic conditions. Test results show a correlation: the measurements from the 50 L specimens were consistently higher than those from the 6 L specimens. However, the Q ∞ and r values of the 30 L specimen were similar to those of the 50 L specimen. Based on the above correlation, the adiabatic temperature rise of the 50 L specimen could be predicted using the results of the 6 L and 30 L specimens. Therefore, it is thought that this correlation can be used for on-site concrete quality control and basic research.

  18. Influence of specimen size/type on the fracture toughness of five irradiated RPV materials

    Energy Technology Data Exchange (ETDEWEB)

    Sokolov, Mikhail A [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Lucon, Enrico [National Inst. of Standards and Technology (NIST), Boulder, CO (United States)

    2015-01-01

    The Heavy-Section Steel Irradiation (HSSI) Program had previously irradiated five reactor pressure vessel (RPV) steels/welds at fast neutron fluxes of about 4 to 8 x 1011 n/cm2/s (>1 MeV) to fluences from 0.5 to 3.4 1019 n/cm2 and at 288 °C. The unirradiated fracture toughness tests were performed by Oak Ridge National Laboratory with 12.7-mm and 25.4-mm thick (0.5T and 1T) compact specimens, while the HSSI Program provided tensile and 5 x 10-mm three-point bend specimens to SCK-CEN for irradiation in the in-pile section of the Belgian Reactor BR2 at fluxes > 1013 n/cm2/s and subsequent testing by SCK-CEN. The BR2 irradiations were conducted at about 2 and 4 x 1013 n/cm2/s with irradiation temperature between 295 °C and 300 °C (water temperature), and to fluences between 6 and 10 x 1019n/cm2. The irradiation-induced shifts of the Master Curve reference temperatures, ΔT0, for most of the materials deviated from the embrittlement correlations much more than expected, motivating the testing of 5 x 10-mm three-point bend specimens of all five materials in the unirradiated condition to eliminate specimen size and geometry as a variable. Tests of the unirradiated small bend specimens resulted in Master Curve reference temperatures, T0, 25 °C to 53 °C lower than those from the larger compact specimens, meaning that the irradiation-induced reference temperature shifts, ΔT0, were larger than the initial measurements, resulting in much improved agreement between the measured and predicted fracture toughness shifts.

  19. Tension test system for irradiated small specimens operated by remote control

    International Nuclear Information System (INIS)

    Okada, Akira

    1993-01-01

    A robot-based tension test system has been developed to aid in the mechanical testing of highly radioactive specimens. This system reduces radiation hazards from specimens and allows for the uniform precision of testing results independent of experimenters' skills. The robot system is designed to accommodate a miniaturized tension specimen with a gage section 5.5 by 1.2 mm, with a total length and width of 12.5 and 2.3 mm, respectively, and thickness of about 0.2 mm. The system is composed of a manipulating robot, a vibrational-type specimen feeder, a rotating-type specimen tray, a specimen observation system, a simulated tension text fixture, and a microcomputer for controlling the system. This system accomplishes specimen arrangement in the specimen tray, specimen transportation and loading to the test fixture and testing, and removal of the broken specimen from the fixture. These procedures are performed quickly, safely, and with uniform testing precision by computer control remotely by an unskilled experimenter

  20. Electrical Bioimpedance-Controlled Surgical Instrumentation.

    Science.gov (United States)

    Brendle, Christian; Rein, Benjamin; Niesche, Annegret; Korff, Alexander; Radermacher, Klaus; Misgeld, Berno; Leonhardt, Steffen

    2015-10-01

    A bioimpedance-controlled concept for bone cement milling during revision total hip replacement is presented. Normally, the surgeon manually removes bone cement using a hammer and chisel. However, this procedure is relatively rough and unintended harm may occur to tissue at any time. The proposed bioimpedance-controlled surgical instrumentation improves this process because, for example, most risks associated with bone cement removal are avoided. The electrical bioimpedance measurements enable online process-control by using the milling head as both a cutting tool and measurement electrode at the same time. Furthermore, a novel integrated surgical milling tool is introduced, which allows acquisition of electrical bioimpedance data for online control; these data are used as a process variable. Process identification is based on finite element method simulation and on experimental studies with a rapid control prototyping system. The control loop design includes the identified process model, the characterization of noise as being normally distributed and the filtering, which is necessary for sufficient accuracy ( ±0.5 mm). Also, in a comparative study, noise suppression is investigated in silico with a moving average filter and a Kalman filter. Finally, performance analysis shows that the bioimpedance-controlled surgical instrumentation may also performs effectively at a higher feed rate (e.g., 5 mm/s).

  1. Tensile-Creep Test Specimen Preparation Practices of Surface Support Liners

    Science.gov (United States)

    Guner, Dogukan; Ozturk, Hasan

    2017-12-01

    Ground support has always been considered as a challenging issue in all underground operations. Many forms of support systems and supporting techniques are available in the mining/tunnelling industry. In the last two decades, a new polymer based material, Thin Spray-on Liner (TSL), has attained a place in the market as an alternative to the current areal ground support systems. Although TSL provides numerous merits and has different application purposes, the knowledge on mechanical properties and performance of this material is still limited. In laboratory studies, since tensile rupture is the most commonly observed failure mechanism in field applications, researchers have generally studied the tensile testing of TSLs with modification of American Society for Testing and Materials (ASTM) D-638 standards. For tensile creep testing, specimen preparation process also follows the ASTM standards. Two different specimen dimension types (Type I, Type IV) are widely preferred in TSL tensile testing that conform to the related standards. Moreover, molding and die cutting are commonly used specimen preparation techniques. In literature, there is a great variability of test results due to the difference in specimen preparation techniques and practices. In this study, a ductile TSL product was tested in order to investigate the effect of both specimen preparation techniques and specimen dimensions under 7-day curing time. As a result, ultimate tensile strength, tensile yield strength, tensile modulus, and elongation at break values were obtained for 4 different test series. It is concluded that Type IV specimens have higher strength values compared to Type I specimens and moulded specimens have lower results than that of prepared by using die cutter. Moreover, specimens prepared by molding techniques have scattered test results. Type IV specimens prepared by die cutter technique are suggested for preparation of tensile test and Type I specimens prepared by die cutter technique

  2. Effect of Incremental Endoscopic Maxillectomy on Surgical Exposure of the Pterygopalatine and Infratemporal Fossae.

    Science.gov (United States)

    Upadhyay, Smita; Dolci, Ricardo L L; Buohliqah, Lamia; Fiore, Mariano E; Ditzel Filho, Leo F S; Prevedello, Daniel M; Otto, Bradley A; Carrau, Ricardo L

    2016-02-01

    Objective Access to the pterygopalatine and infratemporal fossae presents a significant surgical challenge, owing to their deep-seated location and complex neurovascular anatomy. This study elucidates the benefits of incremental medial maxillectomies to access this region. We compared access to the medial aspect of the infratemporal fossa provided by medial maxillectomy, anteriorly extended medial maxillectomy, endoscopic Denker approach (i.e., Sturmann-Canfield approach), contralateral transseptal approach, and the sublabial anterior maxillotomy (SAM). Methods We studied 10 cadaveric specimens (20 sides) dissecting the pterygopalatine and infratemporal fossae bilaterally. Radius of access was calculated using a navigation probe aligned with the endoscopic line of sight. Area of exposure was calculated as the area removed from the posterior wall of maxillary sinus. Surgical freedom was calculated by computing the working area at the proximal end of the instrument with the distal end fixed at a target. Results The endoscopic Denker approach offered a superior area of exposure (8.46 ± 1.56 cm(2)) and superior surgical freedom. Degree of lateral access with the SAM approach was similar to that of the Denker. Conclusion Our study suggests that an anterior extension of the medial maxillectomy or a cross-court approach increases both the area of exposure and surgical freedom. Further increases can be seen upon progression to a Denker approach.

  3. Bone biopsy needles. Mechanical properties, needle design and specimen quality

    International Nuclear Information System (INIS)

    Keulers, Annika; Penzkofer, T.; Cunha-Cruz, V.C.; Bruners, P.; Helmholtz Inst. fuer biomedizinische Technik, Aachen; Braunschweig, T.; Schmitz-Rode, T.; Mahnken, A.; Helmholtz Inst. fuer biomedizinische Technik, Aachen

    2011-01-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. Materials and Methods: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Results: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Conclusion: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. (orig.)

  4. Surgical Site Infection Following Fixation of Acetabular Fractures.

    Science.gov (United States)

    Iqbal, Faizan; Younus, Sajid; Asmatullah; Zia, Osama Bin; Khan, Naveed

    2017-09-01

    Acetabular fractures are mainly caused by high energy trauma. Surgical fixation of these fractures requires extensive surgical exposure which increases the length of operation and blood loss as well. This may increase the risk of surgical site infection. Our aim is to evaluate the prevalence of surgical site infections and the risk factors associated with it so as to minimize its chances. A total of 261 patients who underwent acetabular fracture surgery were retrospectively reviewed. Patients were divided into 2 groups, with or without surgical site infection. Factors examined include patients' gender, age, body mass index (BMI), time between injury and surgery, operative time, estimated blood loss, number of packed red blood cell transfused, length of total intensive care unit (ICU) stay, fracture type, surgical approach, smoking status, patients' comorbids and associated injuries. Fourteen patients (5.4%) developed surgical site infection. Out of 14 infections, 4 were superficial and 10 were deep. The factors that were found to be associated with surgical site infection following acetabular fracture fixation were prolonged operation time, increased BMI, prolonged ICU stay, larger amount of packed red blood cell transfused and associated genitourinary and abdominal trauma. In our study, we conclude that measures should be undertaken to attenuate the chances of surgical site infection in this major surgery by considering the risk factors significantly associated with it.

  5. Evaluation on ductile tearing properties of girth weld pipelines using SE(T) and SE(B) specimens

    Energy Technology Data Exchange (ETDEWEB)

    Mathias, Leonardo Luiz Siqueira; Ruggieri, Claudio [Universidade de Sao Paulo (USP), SP (Brazil). Dept. de Engenharia Naval e Oceanica

    2012-07-01

    Predictive methodologies aimed at quantifying the impact of defects in oil and gas pipelines play a key role in safety assessment procedures of in-service facilities. Current methodologies for structural integrity assessments advocate the use of geometry dependent resistance curves so that crack-tip constraint in the test specimen closely matches the crack tip constraint for the structural component. Testing standards now under development to measure fracture resistance of pipeline steels (J and CTOD) most often employ single edge notched specimens under tension (SENT) to match a postulated defect in the structural component. This paper presents an investigation of the ductile tearing properties for a girth weld of an API 5L X80 pipeline steel using experimentally measured crack growth resistance curves (J-R curves). Testing of the girth weld pipeline steels employed side-grooved, clamped SE(T) specimen with center-crack weld and side-grooved, three-point bending SE(B) (or SENB) specimens to determine the J-R curves. The methods were compared in terms of geometry, relative crack size and crack-tip constraint, and the results were applied to a case study, to evaluate the degree of conservativeness in defect acceptance criteria. The tests involving SE(B) specimens are usually considered conservative, however, the comparison between this two methods may point an accurate alternative for girth weld assessments, since adequate geometry is adopted to describe accurately the structure's behavior. (author)

  6. Measurement of the thickness of the bronchial epithelium

    International Nuclear Information System (INIS)

    Bowden, D.H.; Baldwin, F.

    1989-02-01

    Cancer of the lung in uranium miners is thought to be related to the inhalation of gaseous radon daughters which become attached to molecules of water vapour or to dust particles. Since, the depth of tissue penetration by alpha particles is short, the thickness of the epithelium that lines the bronchial tree may be a critical factor in the development of cancers at specific sites in the lung. The objectives of the present study were: 1) to measure the thickness of human bronchial epithelium; 2) to determine the distribution and depth of the nuclei of basal cells in the bronchial epithelium; and 3) to compare these parameters in groups of smokers and non-smokers. Twenty-nine surgically removed specimens of the lung were examined (26 smokers, 3 non-smokers). The specimens were fixed and prepared for examination by light and electron microscopy. Blocks of tissue were oriented so that the maximum number of bronchi were cut in cross-section; measurements included bronchi of all sizes from bronchial generations (1≥ 9.01 mm) diameter to the smallest bronchioles, generations 7 - 16 (0.26 - 2.0 mm). Comparison of measurements in smokers and non-smokers show no significant differences, so that the 29 cases are considered to represent a homogeneous group. With progressive divisions of the bronchi, the epithelium decreases in thickness. Of more importance are the figures relating to the distance from the cell surface to the underlying nucleus. Here too, with the exception of goblet cells, the measurements are significantly smaller in generations 7 - 16 than in generation 1

  7. Peritonitis: 10 years' experience in a single surgical unit.

    Science.gov (United States)

    Agarwal, Nitin; Saha, Sudipta; Srivastava, Anurag; Chumber, Sunil; Dhar, Anita; Garg, Sanket

    2007-01-01

    Peritonitis secondary to gut perforation is still one of the commonest surgical emergencies in India and is associated with high morbidity and mortality. The present study examines the aetiology and outcome of peritonitis cases operated on in our surgical unit, and compares our findings with those of previous studies performed between 1981 and 1991. A retrospective study of 260 peritonitis patients operated on in a single surgical unit from 1995 to 2006 was done and data involving clinical presentation, operative findings and post-operative course were studied and analysed. Causes of peritonitis were small bowel perforation (96 ileal, 17 jejunal), peptic perforation (45 duodenal, 16 gastric), appendicular perforation (36), primary peritonitis (8), and others (42). The incidence of major complications was 25% (burst-11%, leak-5%, intraabdominal abscess-5%, multi-organ failure-6.5%). The overall mortality was 10%. High mortality was observed in jejunal, gall bladder and liver abscess perforation cases (> 20%). Histopathological evaluation (143 specimens) revealed tuberculosis in 42 (mostly small bowel), malignancy in 8, and inflammation in the rest. Comparisons with a similar study carried out in the same unit and published in 1995 revealed similar demographic features and mortality, but a change in the most common cause (peptic ulcer perforation to small bowel perforation), and an increased performance of enterostomy compared with primary repair in small bowel perforation and a decrease in the leak rate (13% to 4%). Small bowel perforation is the commonest form of perforation and the mortality rate associated with peritonitis remains unchanged.

  8. Shoulder morbidity after non-surgical treatment of the neck

    International Nuclear Information System (INIS)

    Wouwe, Merian van; Bree, Remco de; Kuik, Dirk J.; Goede, Cees J.T. de; Verdonck-de Leeuw, Irma M.; Doornaert, Patricia; Rene Leemans, C.

    2009-01-01

    Background and purpose: Reports on shoulder function after non-surgical treatment are not available. In the present study shoulder morbidity after surgical and non-surgical treatment of the neck is determined and compared. Materials and methods: In 100 head and neck cancer patients 174 neck sides were treated by surgery (n = 51) or (chemo)radiation (n = 123). Abduction, anteflexion, endorotation and exorotation were assessed. Subjective measurements were performed using the Visual Analogue Scale for pain, the Shoulder Disability Questionnaire (SDQ) and stiffness reporting. Results: Predictive factors for SDQ-score > 0 (n = 54) were VAS pain score, stiffness, abduction, anteflexion, physiotherapy, low shoulder position and surgical treatment. The SDQ, stiffness and pain scores were significantly higher in the surgically treated group than in the non-surgical group (p < 0.01). Anteflexion, abduction and exorotation were less impaired in the non-surgically treated group than in the surgically treated group (p < 0.01). No differences between neck dissection and neck dissection with post-operative radiotherapy, and radiotherapy and chemoradiation were found for these movements. Conclusions: Shoulder morbidity is often present after non-surgical treatment of the neck, but to a lesser extent compared to surgical treatment. Radiotherapy adds no morbidity to neck dissection and chemotherapy does not add extra morbidity to primary radiation

  9. Dual-Energy CT of Rectal Cancer Specimens

    DEFF Research Database (Denmark)

    Al-Najami, Issam; Beets-Tan, Regina G H; Madsen, Gunvor

    2016-01-01

    is represented by a certain effective Z value, which allows for information on its composition. OBJECTIVE: We wanted to standardize a method for dual-energy scanning of rectal specimens to evaluate the sensitivity and specificity of benign versus malignant lymph node differentiation. Histopathological evaluation...... cancer. MAIN OUTCOME MEASURES: We measured accuracy of differentiating benign from malignant lymph nodes by investigating the following: 1) gadolinium, iodine, and water concentrations in lymph nodes; 2) dual-energy ratio; 3) dual-energy index; and 4) effective Z value. RESULTS: Optimal discriminations...... between benign and malignant lymph nodes were obtained using the following cutoff values: 1) effective Z at 7.58 (sensitivity, 100%; specificity, 90%; and accuracy, 93%), 2) dual-energy ratio at 1.0 × 10 (sensitivity, 96%; specificity, 87%; and accuracy, 90%), 3) dual-energy index at 0.03 (sensitivity, 97...

  10. A Debonded Sandwich Specimen Under Mixed Mode Bending (MMB)

    DEFF Research Database (Denmark)

    Quispitupa, Amilcar; Berggreen, Christian; Carlsson, Leif A.

    2008-01-01

    Face/core interface crack propagation in sandwich specimens is analyzed. A thorough analysis of the typical failure modes in sandwich composites was performed in order to design the MMB specimen to promote face/core debond fracture. Displacement, compliance and energy release rate expressions...... for the MMB specimen were derived from a superposition analysis. An experimental verification of the methodology proposed was performed using MMB sandwich specimens with H100 PVC foam core and E-glass/polyester non-crimp quadro-axial [0/45/90/-45]s DBLT-850 faces. Different mixed mode loadings were applied...

  11. Investing in a Surgical Outcomes Auditing System

    Science.gov (United States)

    Bermudez, Luis; Trost, Kristen; Ayala, Ruben

    2013-01-01

    Background. Humanitarian surgical organizations consider both quantity of patients receiving care and quality of the care provided as a measure of success. However, organizational efficacy is often judged by the percent of resources spent towards direct intervention/surgery, which may discourage investment in an outcomes monitoring system. Operation Smile's established Global Standards of Care mandate minimum patient followup and quality of care. Purpose. To determine whether investment of resources in an outcomes monitoring system is necessary and effectively measures success. Methods. This paper analyzes the quantity and completeness of data collected over the past four years and compares it against changes in personnel and resources assigned to the program. Operation Smile began investing in multiple resources to obtain the missing data necessary to potentially implement a global Surgical Outcomes Auditing System. Existing personnel resources were restructured to focus on postoperative program implementation, data acquisition and compilation, and training materials used to educate local foundation and international employees. Results. An increase in the number of postoperative forms and amount of data being submitted to headquarters occurred. Conclusions. Humanitarian surgical organizations would benefit from investment in a surgical outcomes monitoring system in order to demonstrate success and to ameliorate quality of care. PMID:23401763

  12. 2015 Accomplishments-Tritium aging studies on stainless steel. Effects of hydrogen isotopes, crack orientation, and specimen geometry on fracture toughness

    Energy Technology Data Exchange (ETDEWEB)

    Morgan, Michael J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-01-01

    This study reports on the effects of hydrogen isotopes, crack orientation, and specimen geometry on the fracture toughness of stainless steels. Fracture toughness variability was investigated for Type 21-6-9 stainless steel using the 7K0004 forging. Fracture toughness specimens were cut from the forging in two different geometric configurations: arc shape and disc shape. The fracture toughness properties were measured at ambient temperature before and after exposure to hydrogen gas and compared to prior studies. There are three main conclusions that can be drawn from the results. First, the fracture toughness properties of actual reservoir forgings and contemporary heats of steel are much higher than those measured in earlier studies that used heats of steel from the 1980s and 1990s and forward extruded forgings which were designed to simulate reservoir microstructures. This is true for as-forged heats as well as forged heats exposed to hydrogen gas. Secondly, the study confirms the well-known observation that cracks oriented parallel to the forging grain flow will propagate easier than those oriented perpendicular to the grain flow. However, what was not known, but is shown here, is that this effect is more pronounced, particularly after hydrogen exposures, when the forging is given a larger upset. In brick forgings, which have a relatively low amount of upset, the fracture toughness variation with specimen orientation is less than 5%; whereas, in cup forgings, the fracture toughness is about 20% lower than that forging to show how specimen geometry affects fracture toughness values. The American Society for Testing Materials (ASTM) specifies minimum specimen section sizes for valid fracture toughness values. However, sub-size specimens have long been used to study tritium effects because of the physical limitation of diffusing hydrogen isotopes into stainless steel at mild temperatures so as to not disturb the underlying forged microstructure. This study shows

  13. Morphohistological and surgical anatomy of the sinus interdigitalis in Egyptian native breeds of sheep

    Directory of Open Access Journals (Sweden)

    A.S. Awaad

    2015-06-01

    Full Text Available The current study aimed to characterize the gross and microscopic structures of the interdigital sinus in Egyptian native breeds of sheep and goats (Baladi sheep and goats to aid in conducting farther studies on such sinus and its surgical importance. The study was carried out on the distal fore and hind limb specimens (below the fetlock joint obtained from healthy mature ten Baladi sheep and ten Baladi goats of both sexes. For sheep, thirty specimens were subjected to gross anatomical investigation and the other ten specimens were used for histological examination. While, the forty goats fore and hind feet specimens were examined grossly. The results obtained revealed the presence of a well-developed interdigital sinus in Baladi sheep, but there was no evidence for the existence of this unique structure in all examined specimens of Baladi goats. Such sinus appeared grossly as a pipe-like, composed of two parts; body (corpus and neck (column which opened in the skin of the interdigital area with an external orifice. The body consisted of three distinct parts in the forefeet and a single part in the hind feet. Histologically, the wall in body and neck regions of the interdigital sinus composed of three distinct layers; epidermis, dermis and a fibrous capsule. Many sebaceous glands, hair follicles and sweat glands in addition to the glandular apocrine gland were distributed within the dermis. The secretory adenomers of the interdigital sinus arranged in different lobules and lined with cuboidal cells with bleb-like projections. It reacted positively with Periodic Acid Schiff (PAS, Sudan black and Sudan III stains, on the other hand it negatively reacted with Alcian blue stain (AB.

  14. Do psychological variables affect early surgical recovery?

    Directory of Open Access Journals (Sweden)

    Michael N Mavros

    Full Text Available BACKGROUND: Numerous studies have examined the effect of psychological variables on surgical recovery, but no definite conclusion has been reached yet. We sought to examine whether psychological factors influence early surgical recovery. METHODS: We performed a systematic search in PubMed, Scopus and PsycINFO databases to identify studies examining the association of preoperative psychological variables or interventions with objectively measured, early surgical outcomes. RESULTS: We identified 16 eligible studies, 15 of which reported a significant association between at least one psychological variable or intervention and an early postoperative outcome. However, most studies also reported psychological factors not influencing surgical recovery and there was significant heterogeneity across the studies. Overall, trait and state anxiety, state anger, active coping, subclinical depression, and intramarital hostility appeared to complicate recovery, while dispositional optimism, religiousness, anger control, low pain expectations, and external locus of control seemed to promote healing. Psychological interventions (guided relaxation, couple support visit, and psychiatric interview also appeared to favor recovery. Psychological factors unrelated to surgical outcomes included loneliness, perceived social support, anger expression, and trait anger. CONCLUSION: Although the heterogeneity of the available evidence precludes any safe conclusions, psychological variables appear to be associated with early surgical recovery; this association could bear important implications for clinical practice. Large clinical trials and further analyses are needed to precisely evaluate the contribution of psychology in surgical recovery.

  15. The effect of specimen size on the ductile/brittle transition temperature in an A533B pressure vessel steel

    International Nuclear Information System (INIS)

    Green, G.; Knott, J.F.

    It was ascertained that it is possible to relate critical crack opening displacement (COD) values, deltasub(crit), obtained on small specimens of A 533-B pressure vessel steel to the fracture toughness value representing the initiation of fracture in a large structure. The variation of deltasub(crit) with temperature is given. A sharp increase in deltasub(crit) is observed above a temperature of approximately -100 degC and this was found to be associated with the initiation of small amounts of fibrous fracture, prior to a cleavage instability. An upper limit to the deltasub(crit) values was obtained above -50 degC, where the fracture was found to be fully ductile. Values of deltasub(crit) estimated from the valid fracture toughness results are shown for comparison. At low temperatures the estimated deltasub(crit) values are seen to be less than those measured in the small bend specimens and the sharp increase in the estimated deltasub(crit) values occurs at a higher temperature, approximately 0 degC. The room temperature deltasub(crit) value, estimated from the valid toughness results (0.15 mm) compares well with COD for the initiation of fibrous fracture, measured at the same temperature in small bend specimens (0.175 mm). The following conclusions were drawn from the experiments: 1. The ductile/brittle transition temperature, determined by critical COD measurements, is influenced by the relaxation of triaxial stresses in small specimens. 2. It is possible to relate critical COD values for the initiation of fibrous fracture, measured in small specimens, to the fracture toughness representing this behaviour in a large structure

  16. Validation of full-field optical coherence tomography in distinguishing malignant and benign tissue in resected pancreatic cancer specimens.

    Directory of Open Access Journals (Sweden)

    Labrinus van Manen

    Full Text Available Pancreatic cancer is the fourth leading cause of cancer-related mortality in the United States. The minority of patients can undergo curative-intended surgical therapy due to progressive disease stage at time of diagnosis. Nonetheless, tumor involvement of surgical margins is seen in up to 70% of resections, being a strong negative prognostic factor. Real-time intraoperative imaging modalities may aid surgeons to obtain tumor-free resection margins. Full-field optical coherence tomography (FF-OCT is a promising diagnostic tool using high-resolution white-light interference microscopy without tissue processing. Therefore, we composed an atlas of FF-OCT images of malignant and benign pancreatic tissue, and investigated the accuracy with which the pathologists could distinguish these.One hundred FF-OCT images were collected from specimens of 29 patients who underwent pancreatic resection for various indications between 2014 and 2016. One experienced gastrointestinal pathologist and one pathologist in training scored independently the FF-OCT images as malignant or benign blinded to the final pathology conclusion. Results were compared to those obtained with standard hematoxylin and eosin (H&E slides.Overall, combined test characteristics of both pathologists showed a sensitivity of 72%, specificity of 74%, positive predictive value of 69%, negative predictive value of 79% and an overall accuracy of 73%. In the subset of pancreatic ductal adenocarcinoma patients, 97% of the FF-OCT images (n = 35 were interpreted as tumor by at least one pathologist. Moreover, normal pancreatic tissue was recognised in all cases by at least one pathologist. However, atrophy and fibrosis, serous cystadenoma and neuroendocrine tumors were more often wrongly scored, in 63%, 100% and 25% respectively.FF-OCT could distinguish normal pancreatic tissue from pathologic pancreatic tissue in both processed as non-processed specimens using architectural features. The accuracy in

  17. Grain tracing and strain determination in a Be compact tension specimen using synchrotron radiation

    International Nuclear Information System (INIS)

    Varma, R.; Green, R.; Garcia, M.D.; Satyam, P.V.; Yun, W.B.; Maser, J.; Kai, Z.; Lai, B.; Sinha, S.K.

    1999-01-01

    X-ray synchrotron radiation of high (11 KeV) energy and high flux (10 10 photons per square centimeter per second) has been used to measure strains and polycrystallinity in 6-mm thick polycrystalline beryllium compact tension (CT) specimens at and around the crack tip (for fatigue-precracked sample) or at chevron notch point under load or no-load conditions. The authors demonstrated the feasibility strain field mapping as well as determining the polycrystallinity at or near the points of maximum load in beryllium CT specimens. The experimental techniques and results will be discussed

  18. Occupational stress and related factors among surgical residents in Korea.

    Science.gov (United States)

    Kang, Sanghee; Jo, Hye Sung; Boo, Yoon Jung; Lee, Ji Sung; Kim, Chong Suk

    2015-11-01

    The application rate for surgical residents in Korea has continuously decreased over the past few years. The demanding workload and the occupational stress of surgical training are likely causes of this problem. The aim of this study was to investigate occupational stress and its related factors in Korean surgical residents. With the support of the Korean Surgical Society, we conducted an electronic survey of Korean surgical residents related to occupational stress. We used the Korean Occupational Stress Scale (KOSS) to measure occupational stress. We analyzed the data focused on the stress level and the factors associated with occupational stress. The mean KOSS score of the surgical residents was 55.39, which was significantly higher than that of practicing surgeons (48.16, P occupation rate and exercise were all significantly associated with KOSS score. Surgical residents have high occupational stress compared to practicing surgeons and other professionals. Their mean number of assigned patients, resident recruitment rate and exercise were all significantly associated with occupational stress for surgical residents.

  19. Improving core surgical training in a major trauma centre.

    Science.gov (United States)

    Morris, Daniel L J; Bryson, David J; Ollivere, Ben J; Forward, Daren P

    2016-06-01

    English Major Trauma Centres (MTCs) were established in April 2012. Increased case volume and complexity has influenced trauma and orthopaedic (T&O) core surgical training in these centres. To determine if T&O core surgical training in MTCs meets Joint Committee on Surgical Training (JCST) quality indicators including performance of T&O operative procedures and consultant supervised session attendance. An audit cycle assessing the impact of a weekly departmental core surgical trainee rota. The rota included allocated timetabled sessions that optimised clinical and surgical learning opportunities. Intercollegiate Surgical Curriculum Programme (ISCP) records for T&O core surgical trainees at a single MTC were analysed for 8 months pre and post rota introduction. Outcome measures were electronic surgical logbook evidence of leading T&O operative procedures and consultant validated work-based assessments (WBAs). Nine core surgical trainees completed a 4 month MTC placement pre and post introduction of the core surgical trainee rota. Introduction of core surgical trainee rota significantly increased the mean number of T&O operative procedures led by a core surgical trainee during a 4 month MTC placement from 20.2 to 34.0 (pcore surgical trainee during a 4 month MTC placement was significantly increased (0.3 vs 2.4 [p=0.04]). Those of dynamic hip screw fixation (2.3 vs 3.6) and ankle fracture fixation (0.7 vs 1.6) were not. Introduction of a core surgical trainee rota significantly increased the mean number of consultant validated WBAs completed by a core surgical trainee during a 4 month MTC placement from 1.7 to 6.6 (pcore surgical trainee rota utilising a 'problem-based' model can significantly improve T&O core surgical training in MTCs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Fractographic examination of HT-9 and 9Cr-1Mo Charpy specimens irradiated in the AD-2 test

    International Nuclear Information System (INIS)

    Gelles, D.S.; Hu, W.L.

    1983-01-01

    Fracture surface topologies have been examined using scanning electron microscopy for 20 selected half sized Charpy impact specimens of HT-9 and Modified 9Cr-1Mo in order to provide improved understanding of fracture toughness degradation as a result of irradiation for Path E alloys. The specimen matrix included unirradiated specimens and specimens irradiated in EBR-II in the AD-2 experiment. Also, hardness measurements have been made on selected irradiated Charpy specimens. The results of examinations indicate that irradiation hardening due to G-phase formation at 390 0 C is responsible for the large shift in ductile-to-brittle transition temperature (DBTT) found in HT-9. Toughness degradation in HT-9 observed following higher temperature irradiations is attributed to precipitation at delta ferrite stringers. Reductions in toughness as a consequence of irradiation in Modified 9Cr-1Mo are attributed to in-reactor precipitation of (V,Nb)C and M 23 C 6 . It is shown that crack propagation rates for ductile and brittle failure modes can be measured, that they differ by over an order of magnitude and that unexpected multiple shifts in fracture mode from ductile to brittle failure can be attributed to the effect of delta ferrite stringers on crack propagation rates

  1. Design and use of nonstandard tensile specimens for irradiated materials testing

    International Nuclear Information System (INIS)

    Panayotou, N.F.

    1984-10-01

    Miniature, nonstandard, tensile-type specimens have been developed for use in radiation effects experiments at high energy neutron sources where the useful radiation volume is as small as a few cubic centimeters. The end result of our development is a sheet-type specimen, 12.7 mm long with a 5.1 mm long, 1.0 mm wide gage section, which is typically fabricated from 0.25 mm thick sheet stock by a punching technique. Despite this miniature geometry, it has been determined that the data obtained using these miniature specimens are in good agreement with data obtained using much larger specimens. This finding indicates that miniature tensile specimen data may by used for engineering design purposes. Furthermore, it is clear that miniature tensile specimen technology is applicable to fields other than the study of radiation effects. This paper describes the miniature specimen technology which was developed and compares the data obtained from these miniature specimens to data obtained from much larger specimens. 9 figures

  2. Comparative Tissue Proteomics of Microdissected Specimens Reveals Novel Candidate Biomarkers of Bladder Cancer*

    Science.gov (United States)

    Chen, Chien-Lun; Chung, Ting; Wu, Chih-Ching; Ng, Kwai-Fong; Yu, Jau-Song; Tsai, Cheng-Han; Chang, Yu-Sun; Liang, Ying; Tsui, Ke-Hung; Chen, Yi-Ting

    2015-01-01

    More than 380,000 new cases of bladder cancer are diagnosed worldwide, accounting for ∼150,200 deaths each year. To discover potential biomarkers of bladder cancer, we employed a strategy combining laser microdissection, isobaric tags for relative and absolute quantitation labeling, and liquid chromatography-tandem MS (LC-MS/MS) analysis to profile proteomic changes in fresh-frozen bladder tumor specimens. Cellular proteins from four pairs of surgically resected primary bladder cancer tumor and adjacent nontumorous tissue were extracted for use in two batches of isobaric tags for relative and absolute quantitation experiments, which identified a total of 3220 proteins. A DAVID (database for annotation, visualization and integrated discovery) analysis of dysregulated proteins revealed that the three top-ranking biological processes were extracellular matrix organization, extracellular structure organization, and oxidation-reduction. Biological processes including response to organic substances, response to metal ions, and response to inorganic substances were highlighted by up-expressed proteins in bladder cancer. Seven differentially expressed proteins were selected as potential bladder cancer biomarkers for further verification. Immunohistochemical analyses showed significantly elevated levels of three proteins—SLC3A2, STMN1, and TAGLN2—in tumor cells compared with noncancerous bladder epithelial cells, and suggested that TAGLN2 could be a useful tumor tissue marker for diagnosis (AUC = 0.999) and evaluating lymph node metastasis in bladder cancer patients. ELISA results revealed significantly increased urinary levels of both STMN1 and TAGLN2 in bladder cancer subgroups compared with control groups. In comparisons with age-matched hernia urine specimens, urinary TAGLN2 in bladder cancer samples showed the largest fold change (7.13-fold), with an area-under-the-curve value of 0.70 (p < 0.001, n = 205). Overall, TAGLN2 showed the most significant

  3. Evaluation of the Behavior of Technova Corporation Rod-Stiffened Stitched Compression Specimens

    Science.gov (United States)

    Jegley, Dawn C.

    2013-01-01

    Under Space Act Agreement 1347 between NASA and Technova Corporation, Technova designed and fabricated two carbon-epoxy crippling specimens and NASA loaded them to failure in axial compression. Each specimen contained a pultruded rod stiffener which was held to the specimen skin with through-the-thickness stitches. One of these specimens was designed to be nominally the same as pultruded rod stitched specimens fabricated by Boeing under previous programs. In the other specimen, the rod was prestressed in a Technova manufacturing process to increase its ability to carrying compressive loading. Experimental results demonstrated that the specimen without prestressing carried approximately the same load as the similar Boeing specimens and that the specimen with prestressing carried significantly more load than the specimen without prestressing.

  4. An Experimental Study of Shear-Dominated Failure in the 2013 Sandia Fracture Challenge Specimen

    Energy Technology Data Exchange (ETDEWEB)

    Corona, Edmundo [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Deibler, Lisa Anne [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Reedlunn, Benjamin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ingraham, Mathew Duffy [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Williams, Shelley [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-04-01

    This report presents an experimental study motivated by results obtained during the 2013 Sandia Fracture Challenge. The challenge involved A286 steel, shear-dominated compression specimens whose load-deflection response contained a load maximum fol- lowed by significant displacement under decreasing load, ending with a catastrophic fracture. Blind numerical simulations deviated from the experiments well before the maximum load and did not predict the failure displacement. A series of new tests were conducted on specimens machined from the original A286 steel stock to learn more about the deformation and failure processes in the specimen and potentially improve future numerical simulations. The study consisted of several uniaxial tension tests to explore anisotropy in the material, and a set of new tests on the compression speci- men. In some compression specimen tests, stereo digital image correlation (DIC) was used to measure the surface strain fields local to the region of interest. In others, the compression specimen was loaded to a given displacement prior to failure, unloaded, sectioned, and imaged under the microscope to determine when material damage first appeared and how it spread. The experiments brought the following observations to light. The tensile tests revealed that the plastic response of the material is anisotropic. DIC during the shear- dominated compression tests showed that all three in-plane surface strain components had maxima in the order of 50% at the maximum load. Sectioning of the specimens revealed no signs of material damage at the point where simulations deviated from the experiments. Cracks and other damage did start to form approximately when the max- imum load was reached, and they grew as the load decreased, eventually culminating in catastrophic failure of the specimens. In addition to the steel specimens, a similar study was carried out for aluminum 7075-T651 specimens. These specimens achieved much lower loads and displacements

  5. Micro-surgical endodontics.

    Science.gov (United States)

    Eliyas, S; Vere, J; Ali, Z; Harris, I

    2014-02-01

    Non-surgical endodontic retreatment is the treatment of choice for endodontically treated teeth with recurrent or residual disease in the majority of cases. In some cases, surgical endodontic treatment is indicated. Successful micro-surgical endodontic treatment depends on the accuracy of diagnosis, appropriate case selection, the quality of the surgical skills, and the application of the most appropriate haemostatic agents and biomaterials. This article describes the armamentarium and technical procedures involved in performing micro-surgical endodontics to a high standard.

  6. The trans-frontal-sinus subcranial approach for removal of large olfactory groove meningiomas: surgical technique and comparison to other approaches.

    Science.gov (United States)

    Boari, Nicola; Gagliardi, Filippo; Roberti, Fabio; Barzaghi, Lina Raffaella; Caputy, Anthony J; Mortini, Pietro

    2013-05-01

    Several surgical approaches have been previously reported for the treatment of olfactory groove meningiomas (OGM).The trans-frontal-sinus subcranial approach (TFSSA) for the removal of large OGMs is described, comparing it with other reported approaches in terms of advantages and drawbacks. The TFSSA was performed on cadaveric specimens to illustrate the surgical technique. The surgical steps of the TFSSA and the related anatomical pictures are reported. The approach was adopted in a clinical setting; a case illustration is reported to demonstrate the feasibility of the described approach and to provide intraoperative pictures. The TFSSA represents a possible route to treat large OGMs. The subcranial approach provides early devascularization of the tumor, direct tumor access from the base without traction on the frontal lobes, good overview of dissection of the optic nerves and anterior cerebral arteries, and dural reconstruction with pedicled pericranial flap. Georg Thieme Verlag KG Stuttgart · New York.

  7. A Surgical Business Composite Score for Army Medicine.

    Science.gov (United States)

    Stoddard, Douglas R; Robinson, Andrew B; Comer, Tracy A; Meno, Jenifer A; Welder, Matthew D

    2016-06-01

    Measuring surgical business performance for Army military treatment facilities is currently done through 6 business metrics developed by the Army Medical Command (MEDCOM) Surgical Services Service Line (3SL). Development of a composite score for business performance has the potential to simplify and synthesize measurement, improving focus for strategic goal setting and implementation. However, several considerations, ranging from data availability to submetric selection, must be addressed to ensure the score is accurate and representative. This article presents the methodology used in the composite score's creation and presents a metric based on return on investment and a measure of cases recaptured from private networks. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  8. Reduction of Specimen Size for the Full Simultaneous Characterization of Thermoelectric Performance

    Science.gov (United States)

    Vasilevskiy, D.; Simard, J.-M.; Masut, R. A.; Turenne, S.

    2017-05-01

    The successful implementation of thermoelectric (TE) materials for waste heat recovery depends strongly on our ability to increase their performance. This challenge continues to generate a renewed interest in novel high TE performance compounds. The technological difficulties in producing homogeneous ingots of new compounds or alloys with regular shape and a size sufficiently large to prepare several samples that are usually needed for a separate measurement of all TE parameters are well known. It creates a situation whereby material performance could be critically over- or under-evaluated at the first stages of the research process of a new material. Both cases would equally lead to negative consequences. Thus, minimizing the specimen size yet keeping it adequate for accurate material characterization becomes extremely important. In this work we report the experimental validation of reliable simultaneous measurements of the four most relevant TE parameters on a single bismuth telluride alloy based specimen of 4 mm × 4 mm × 1.4 mm in size. This translates in roughly 140 mg in weight for one of the heaviest TE materials, as was used in this study, and coefficient, electrical resistivity, thermal conductivity and the figure of merit were simultaneously assessed from 300 K to 440 K with increments of 20 K, 15 K, 10 K, 5 K, and 1 K. Our choice of a well-known homogeneous material has been made to increase measurement reliability and accuracy, but the results are expected to be valid for the full TE characterization of any unknown material. These results show a way to significantly decrease specimen sizes which has the potential to accelerate investigation of novel TE materials for large scale waste heat recovery.

  9. Preserve specimens for reproducibility

    Czech Academy of Sciences Publication Activity Database

    Krell, F.-T.; Klimeš, Petr; Rocha, L. A.; Fikáček, M.; Miller, S. E.

    2016-01-01

    Roč. 539, č. 7628 (2016), s. 168 ISSN 0028-0836 Institutional support: RVO:60077344 Keywords : reproducibility * specimen * biodiversity Subject RIV: EH - Ecology, Behaviour Impact factor: 40.137, year: 2016 http://www.nature.com/nature/journal/v539/n7628/full/539168b.html

  10. Risk management: correct patient and specimen identification in a surgical pathology laboratory. The experience of Infermi Hospital, Rimini, Italy.

    Science.gov (United States)

    Fabbretti, G

    2010-06-01

    Because of its complex nature, surgical pathology practice is prone to error. In this report, we describe our methods for reducing error as much as possible during the pre-analytical and analytical phases. This was achieved by revising procedures, and by using computer technology and automation. Most mistakes are the result of human error in the identification and matching of patient and samples. To avoid faulty data interpretation, we employed a new comprehensive computer system that acquires all patient ID information directly from the hospital's database with a remote order entry; it also provides label and request forms via-Web where clinical information is required before sending the sample. Both patient and sample are identified directly and immediately at the site where the surgical procedures are performed. Barcode technology is used to input information at every step and automation is used for sample blocks and slides to avoid errors that occur when information is recorded or transferred by hand. Quality control checks occur at every step of the process to ensure that none of the steps are left to chance and that no phase is dependent on a single operator. The system also provides statistical analysis of errors so that new strategies can be implemented to avoid repetition. In addition, the staff receives frequent training on avoiding errors and new developments. The results have been shown promising results with a very low error rate (0.27%). None of these compromised patient health and all errors were detected before the release of the diagnosis report.

  11. Consensus statement on surgical pathology of the aorta from the Society for Cardiovascular Pathology and the Association For European Cardiovascular Pathology: II. Noninflammatory degenerative diseases - nomenclature and diagnostic criteria

    NARCIS (Netherlands)

    Halushka, Marc K.; Angelini, Annalisa; Bartoloni, Giovanni; Basso, Cristina; Batoroeva, Lubov; Bruneval, Patrick; Buja, L. Maximilian; Butany, Jagdish; d'Amati, Giulia; Fallon, John T.; Gallagher, Patrick J.; Gittenberger-de Groot, Adriana C.; Gouveia, Rosa H.; Kholova, Ivana; Kelly, Karen L.; Leone, Ornella; Litovsky, Silvio H.; Maleszewski, Joseph J.; Miller, Dylan V.; Mitchell, Richard N.; Preston, Stephen D.; Pucci, Angela; Radio, Stanley J.; Rodriguez, E. Rene; Sheppard, Mary N.; Stone, James R.; Suvarna, S. Kim; Tan, Carmela D.; Thiene, Gaetano; Veinot, John P.; van der Wal, Allard C.

    2016-01-01

    Surgical aortic specimens are usually examined in Pathology Departments as a result of treatment of aneurysms or dissections. A number of diseases, genetic syndromes (Marfan syndrome, Loeys-Dietz syndrome, etc.), and vasculopathic aging processes involved in vascular injury can cause both distinct

  12. Challenges to the development of complex virtual reality surgical simulations.

    Science.gov (United States)

    Seymour, N E; Røtnes, J S

    2006-11-01

    Virtual reality simulation in surgical training has become more widely used and intensely investigated in an effort to develop safer, more efficient, measurable training processes. The development of virtual reality simulation of surgical procedures has begun, but well-described technical obstacles must be overcome to permit varied training in a clinically realistic computer-generated environment. These challenges include development of realistic surgical interfaces and physical objects within the computer-generated environment, modeling of realistic interactions between objects, rendering of the surgical field, and development of signal processing for complex events associated with surgery. Of these, the realistic modeling of tissue objects that are fully responsive to surgical manipulations is the most challenging. Threats to early success include relatively limited resources for development and procurement, as well as smaller potential for return on investment than in other simulation industries that face similar problems. Despite these difficulties, steady progress continues to be made in these areas. If executed properly, virtual reality offers inherent advantages over other training systems in creating a realistic surgical environment and facilitating measurement of surgeon performance. Once developed, complex new virtual reality training devices must be validated for their usefulness in formative training and assessment of skill to be established.

  13. Demonstration of a chamber for strain mapping of steel specimens under mechanical load in a hydrogen environment by synchrotron radiation

    Science.gov (United States)

    Connolly, Matthew; Park, Jun-Sang; Bradley, Peter; Lauria, Damian; Slifka, Andrew; Drexler, Elizabeth

    2018-06-01

    We demonstrate a hydrogen gas chamber suitable for lattice strain measurements and capturing radiographs of a steel specimen under a mechanical load using high energy synchrotron x-rays. The chamber is suitable for static and cyclic mechanical loading. Experiments were conducted at the 1-ID-E end station of the Advanced Photon Source, Argonne National Laboratory. Diffraction patterns show a high signal-to-noise ratio suitable for lattice strain measurements for the specimen and with minimal scattering and overlap from the gas chamber manufactured from aluminum. In situ radiographs of a specimen in the hydrogen chamber show the ability to track a growing crack and to map the lattice strain around the crack with high spatial and strain resolution.

  14. Effect of sized and specimen geometry on the initiation and propagation of the ductile fracture

    International Nuclear Information System (INIS)

    Frund, J.M.; Marini, B.; Bethmont, M.

    1994-02-01

    Strength to the fracture of the pipe in PWR has to be justified with mechanical analyses. These tests are based on the strength to ductile fracture of steels which are tested in lab. The values of resistance to fracture are obtained through tensile tests on CT specimens (determination of J-R curves). The purpose of this study is to justify the sizes of the specimens which have to be used to characterize the strength to ductile fracture of steel in secondary pipes. Tests were conducted on 0,5T-CT, 1T-CT and 2T-CT specimens. Two materials with different suffer contents were studied. The test results show that the JO,2 values gotten from the different specimens are similar. But the strength to ductile fracture in 2T-CT specimens in lower than the one measured in 0,5t-CT and 1T-CT specimens. The surface of fracture of the different specimens displays splits perpendicular to the notch and parallel to the sheet surface. These splits are produced by the separation of the manganese sulfur inclusions. The effect notes on the J-R curves seems to be relevant to these splits. The reason why these splits might be responsible for a decrease of the tearing modulus are not clearly defined up to this point. The results which have been published show the importance of the geometry effects (presence or not of lateral notches...) and the loading mode on the strength to ductile fracture. We note that the curves determined from tests on CT specimens are conservative. A few preliminary studies showed that the geometry effects on resistance to fracture can be studied and explained by using local approach methods. The Rousselier modeling is useful to explain the behaviour of ferritic steels in ductile fracture. (authors). 20 refs., 7 figs., 5 tabs

  15. Biaxial Creep Specimen Fabrication

    Energy Technology Data Exchange (ETDEWEB)

    JL Bump; RF Luther

    2006-02-09

    This report documents the results of the weld development and abbreviated weld qualification efforts performed by Pacific Northwest National Laboratory (PNNL) for refractory metal and superalloy biaxial creep specimens. Biaxial creep specimens were to be assembled, electron beam welded, laser-seal welded, and pressurized at PNNL for both in-pile (JOYO reactor, O-arai, Japan) and out-of-pile creep testing. The objective of this test campaign was to evaluate the creep behavior of primary cladding and structural alloys under consideration for the Prometheus space reactor. PNNL successfully developed electron beam weld parameters for six of these materials prior to the termination of the Naval Reactors program effort to deliver a space reactor for Project Prometheus. These materials were FS-85, ASTAR-811C, T-111, Alloy 617, Haynes 230, and Nirnonic PE16. Early termination of the NR space program precluded the development of laser welding parameters for post-pressurization seal weldments.

  16. Biaxial Creep Specimen Fabrication

    International Nuclear Information System (INIS)

    JL Bump; RF Luther

    2006-01-01

    This report documents the results of the weld development and abbreviated weld qualification efforts performed by Pacific Northwest National Laboratory (PNNL) for refractory metal and superalloy biaxial creep specimens. Biaxial creep specimens were to be assembled, electron beam welded, laser-seal welded, and pressurized at PNNL for both in-pile (JOYO reactor, O-arai, Japan) and out-of-pile creep testing. The objective of this test campaign was to evaluate the creep behavior of primary cladding and structural alloys under consideration for the Prometheus space reactor. PNNL successfully developed electron beam weld parameters for six of these materials prior to the termination of the Naval Reactors program effort to deliver a space reactor for Project Prometheus. These materials were FS-85, ASTAR-811C, T-111, Alloy 617, Haynes 230, and Nirnonic PE16. Early termination of the NR space program precluded the development of laser welding parameters for post-pressurization seal weldments

  17. Peer-assisted teaching of basic surgical skills.

    Science.gov (United States)

    Preece, Ryan; Dickinson, Emily Clare; Sherif, Mohamed; Ibrahim, Yousef; Ninan, Ann Susan; Aildasani, Laxmi; Ahmed, Sartaj; Smith, Philip

    2015-01-01

    Basic surgical skills training is rarely emphasised in undergraduate medical curricula. However, the provision of skills tutorials requires significant commitment from time-constrained surgical faculty. We aimed to determine how a peer-assisted suturing workshop could enhance surgical skills competency among medical students and enthuse them towards a career in surgery. Senior student tutors delivered two suturing workshops to second- and third- year medical students. Suturing performance was assessed before and after teaching in a 10-min suturing exercise (variables measured included number of sutures completed, suture tension, and inter-suture distance). Following the workshop, students completed a questionnaire assessing the effect of the workshop on their suturing technique and their intention to pursue a surgical career. Thirty-five students attended. Eighty-one percent believed their medical school course provided insufficient basic surgical skills training. The mean number of sutures completed post-teaching increased significantly (p teaching, to ± 2.6 mm post-teaching. All students found the teaching environment to be relaxed, and all felt the workshop helped to improve their suturing technique and confidence; 87% found the peer-taught workshop had increased their desire to undertake a career in surgery. Peer-assisted learning suturing workshops can enhance medical students' competence with surgical skills and inspire them towards a career in surgery. With very little staff faculty contribution, it is a cheap and sustainable way to ensure ongoing undergraduate surgical skills exposure.

  18. Mobile surgical skills education unit: a new concept in surgical training.

    Science.gov (United States)

    Shaikh, Faisal M; Hseino, Hazem; Hill, Arnold D K; Kavanagh, Eamon; Traynor, Oscar

    2011-08-01

    Basic surgical skills are an integral part of surgical training. Simulation-based surgical training offers an opportunity both to trainees and trainers to learn and teach surgical skills outside the operating room in a nonpatient, nonstressed environment. However, widespread adoption of simulation technology especially in medical education is prohibited by its inherent higher cost, limited space, and interruptions to clinical duties. Mobile skills laboratory has been proposed as a means to address some of these limitations. A new program is designed by the Royal College of Surgeons in Ireland (RCSI), in an approach to teach its postgraduate basic surgical trainees the necessary surgical skills, by making the use of mobile innovative simulation technology in their own hospital settings. In this article, authors describe the program and students response to the mobile surgical skills being delivered in the region of their training hospitals and by their own regional consultant trainers.

  19. Quantifying surgical complexity with machine learning: looking beyond patient factors to improve surgical models.

    Science.gov (United States)

    Van Esbroeck, Alexander; Rubinfeld, Ilan; Hall, Bruce; Syed, Zeeshan

    2014-11-01

    To investigate the use of machine learning to empirically determine the risk of individual surgical procedures and to improve surgical models with this information. American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP) data from 2005 to 2009 were used to train support vector machine (SVM) classifiers to learn the relationship between textual constructs in current procedural terminology (CPT) descriptions and mortality, morbidity, Clavien 4 complications, and surgical-site infections (SSI) within 30 days of surgery. The procedural risk scores produced by the SVM classifiers were validated on data from 2010 in univariate and multivariate analyses. The procedural risk scores produced by the SVM classifiers achieved moderate-to-high levels of discrimination in univariate analyses (area under receiver operating characteristic curve: 0.871 for mortality, 0.789 for morbidity, 0.791 for SSI, 0.845 for Clavien 4 complications). Addition of these scores also substantially improved multivariate models comprising patient factors and previously proposed correlates of procedural risk (net reclassification improvement and integrated discrimination improvement: 0.54 and 0.001 for mortality, 0.46 and 0.011 for morbidity, 0.68 and 0.022 for SSI, 0.44 and 0.001 for Clavien 4 complications; P risk for individual procedures. This information can be measured in an entirely data-driven manner and substantially improves multifactorial models to predict postoperative complications. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Face/core debond fatigue crack growth characterization using the sandwich mixed mode bending specimen

    DEFF Research Database (Denmark)

    Manca, Marcello; Quispitupa, Amilcar; Berggreen, Christian

    2012-01-01

    Face/core fatigue crack growth in foam-cored sandwich composites is examined using the mixed mode bending (MMB) test method. The mixed mode loading at the debond crack tip is controlled by changing the load application point in the MMB test fixture. Sandwich specimens were manufactured using H45...... and H100 PVC foam cores and E-glass/polyester face sheets. All specimens were pre-cracked in order to define a sharp crack front. The static debond fracture toughness for each material configuration was measured at different mode-mixity phase angles. Fatigue tests were performed at 80% of the static...

  1. Ductile fracture toughness of heavy section pressure vessel steel plate. A specimen-size study of ASTM A 533 steels

    International Nuclear Information System (INIS)

    Williams, J.A.

    1979-09-01

    The ductile fracture toughness, J/sub Ic/, of ASTM A 533, Grade B, Class 1 and ASTM A 533, heat treated to simulate irradiation, was determined for 10- to 100-mm thick compact specimens. The toughness at maximum specimen load was also measured to determine the conservatism of J/sub Ic/. The toughness of ASTM A 533, Grade B, Class 1 steel was 349 kJ/m 2 and at the equivalent upper shelf temperature, the heat treated material exhibited 87 kJ/m 2 . The maximum load fracture toughness was found to be linearly proportional to specimen size, and only specimens which failed to meet ASTM size criteria exhibited maximum load toughness less than J/sub Ic/

  2. Effects of different abutment material and surgical insertion torque on the marginal adaptation of an internal conical interface: an in vitro study.

    Science.gov (United States)

    Farronato, Davide; Pieroni, Stefano; Mangano, Francesco Guido; Briguglio, Francesco; Re, Dino

    2014-10-01

    To evaluate the marginal adaptation at implant-abutment connection of an implant featuring a conical (45° taper) internal hexagonal abutment with a connection depth of 2.5mm, comparing the performance of two identical abutments of different material (titanium grade-4 and Co-Cr-alloy). Twenty implants (3.75 mm×15 mm) were connected to non-matching abutments (5.5 mm×10 mm) of two different materials (titanium grade-4: n=10; Co-Cr-alloy: n=10). The specimens were separately embedded in epoxylite resin, inside copper cylinders, and submerged without covering the most coronal portion (5 mm) of the fixture. Five specimens per group were stressed simulating a surgical 100 Ncm insertion torque, while the others had no torque simulation. All specimens were subjected to a non-axial static load (100 N) in a universal testing machine, under an angle of 30° with respect to the implant axis. Once 100 N load was reached, low shrinkage self-curing resin was injected inside the cylinders, and load was maintained until complete resin polymerization. Specimens were cut and analyzed with optical and scanning-electron-microscope (SEM) to evaluate the marginal adaptation at the implant-abutment connection. Statistical analysis was performed using one-way ANOVA (p=0.02). None of the 20 samples failed. The implant-abutment connection was able to guarantee a good optical seal; SEM analysis confirmed the absence of microgaps. Within the limits of this study (small sample size, limited time) the marginal adaptation of the implant-abutment connection was not affected by the abutment material nor by the application of surgical insertion torque. Copyright © 2014 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  3. The feasibility of prefatigued sub size specimens to fracture mechanical studies in inert and in reactor environments

    International Nuclear Information System (INIS)

    Toivonen, A.; Moilanen, P.; Taehtinen, S.; Aaltonen, P.; Wallin, K.

    1998-01-01

    The feasibility of sub size specimens to fracture mechanical tests in inert and in reactor environment is studied in this paper. The need for using sub size specimens has arised from the need to study highly irradiated materials as well as to study localised stress corrosion cracking, i.e. stress corrosion cracking in very narrow heat affected zones for example in welded thin walled pipes. This paper focuses on the effects of high J-integral values on ductile tearing and on environmentally assisted crack growth rate. The main focus is on the stress corrosion tests. The subject is approached first by theoretical discussion. The experimental study consists of J-R tests in air and of slow J-R tests in simulated boiling water reactor (BWR) environment. In most cases the tests were continued until the J-integral level was significantly above the maximum allowable J values for ductile fracture toughness characterisation prescribed in test standards. The results indicate that the measurement capacity of the specimens depends on the specimen dimensions in J-R tests in air, as could be expected. The measurement capacity limitations are not necessarily important in stress corrosion testing as the environmentally assisted crack growth rate can be measured even without exceeding the J-integral limits given in J-R standards. The theoretical and experimental studies indicate that stress corrosion studies are not limited to linear elastic fracture mechanics approach, but elastic plastic fracture mechanics is applicable as well. (author)

  4. Demonstration of Laser Cutting System for Tube Specimen

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Y. G.; Kim, G. S.; Heo, G. S.; Baik, S. J.; Kim, H. M.; Ahn, S. B. [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated fuel cladding and components interrupted the applying the electric current during the processing. However, it was found that the mechanical testing data of the irradiated specimens with removal of oxide layer was less reliable than the specimens with oxide layer . The laser cutting system using Nd:YAG with fiber optic beam delivery has great potential in material processing applications of the irradiated fuel cladding and components due to non-contact process. Thus, the oxide layer doesn't interrupt the fabrication process during the laser cutting system. In the present study, the laser cutting system was designed to fabricate the mechanical testing specimens from the unirradiated fuel cladding with and without oxide. The feasibility of the laser cutting system was demonstrated for the fabrication of various types of unirradiated specimens. The effect of surface oxide layer was also investigated for machining process of the zirlo fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer. Based on the feasibility studies and demonstration, the design of the laser cutting machine for fully or partially automatic and remotely operable system will be proposed and made.

  5. Modelling and experimental characterisation of a residual stress field in a ferritic compact tension specimen

    International Nuclear Information System (INIS)

    Wenman, M.R.; Price, A.J.; Steuwer, A.; Chard-Tuckey, P.R.; Crocombe, A.

    2009-01-01

    The aim of the work is to elucidate the influence of plasticity behaviour on the residual stress field in a ferritic reactor pressure vessel steel. To this end, we investigate two compressively pre-loaded compact tension (CT) specimens to generate a mechanical residual stress field. One specimen was subsequently pre-cracked by fatigue before both specimens were measured using high-energy synchrotron X-ray diffraction. A fine grain size microstructure (∼5-10 μm grain size) allowed a small X-ray beam slit size and therefore gauge volume. The results provide an excellent data set for validation of finite element (FE) modelling predictions against which they have been compared. The results of both mechanical testing and modelling suggest that the use of a combined hardening model is needed to accurately predict the residual stress field present in the specimen after pre-loading. Some discrepancy between the modelled crack tip stress values and those found by X-ray diffraction remain which can be partly explained by volume averaging effects in the presence of very high stress/strain gradients.

  6. Modelling and experimental characterisation of a residual stress field in a ferritic compact tension specimen

    Energy Technology Data Exchange (ETDEWEB)

    Wenman, M.R., E-mail: m.wenman@imperial.ac.u [Department of Materials, Imperial College London, London SW7 2AZ (United Kingdom); Price, A.J. [Faculty of Engineering and Physical Sciences (J5), University of Surrey, Guildford GU2 7XH (United Kingdom); Steuwer, A. [ESS Scandinavia, Stora Algatan 4, 22350 Lund (Sweden) and Nelson Mandela Metropolitan University, Port Elizabeth 6031 (South Africa); Chard-Tuckey, P.R. [Nuclear Department, Defence College of Management and Technology, HMS Sultan, Gosport, Hants PO12 3BY (United Kingdom); Crocombe, A. [Faculty of Engineering and Physical Sciences (J5), University of Surrey, Guildford GU2 7XH (United Kingdom)

    2009-12-15

    The aim of the work is to elucidate the influence of plasticity behaviour on the residual stress field in a ferritic reactor pressure vessel steel. To this end, we investigate two compressively pre-loaded compact tension (CT) specimens to generate a mechanical residual stress field. One specimen was subsequently pre-cracked by fatigue before both specimens were measured using high-energy synchrotron X-ray diffraction. A fine grain size microstructure (approx5-10 mum grain size) allowed a small X-ray beam slit size and therefore gauge volume. The results provide an excellent data set for validation of finite element (FE) modelling predictions against which they have been compared. The results of both mechanical testing and modelling suggest that the use of a combined hardening model is needed to accurately predict the residual stress field present in the specimen after pre-loading. Some discrepancy between the modelled crack tip stress values and those found by X-ray diffraction remain which can be partly explained by volume averaging effects in the presence of very high stress/strain gradients.

  7. Surgical site infections in an abdominal surgical ward at Kosovo Teaching Hospital.

    Science.gov (United States)

    Raka, Lul; Krasniqi, Avdyl; Hoxha, Faton; Musa, Ruustem; Mulliqi, Gjyle; Krasniqi, Selvete; Kurti, Arsim; Dervishaj, Antigona; Nuhiu, Beqir; Kelmendi, Baton; Limani, Dalip; Tolaj, Ilir

    2008-01-01

    Abdominal surgical site infections (SSI) cause substantial morbidity and mortality for patients undergoing operative procedures. We determined the incidence of and risk factors for SSI after abdominal surgery in the Department of Abdominal Surgery at the University Clinical Centre of Kosovo (UCCK). Prospective surveillance of patients undergoing abdominal surgery was performed between December 2005 and June 2006. CDC definitions were followed to detect SSI and study forms were based on Europe Link for Infection Control through Surveillance (HELICS) protocol. A total of 253 surgical interventions in 225 patients were evaluated. The median age of patients was 42 years and 55.1% of them were male. The overall incidence rate of SSI was 12%. Follow-up was achieved for 84.1% of the procedures. For patients with an SSI, the median duration of hospitalization was 9 days compared with 4 days for those without an SSI (p 2, use of antibiotic prophylaxis and NNIS class of > 2 were all significant at p < .001. The SSI rates for the NNIS System risk classes 0, 1 and 2-3 were 4.2%, 46.7% and 100%, respectively. SSI caused considerable morbidity among surgical patients in UCCK. Appropriate active surveillance and infection control measures should be introduced during preoperative, intra-operative, and postoperative care to reduce infection rates.

  8. Specimen aspect ratio and progressive field strain development of sandstone under uniaxial compression by three-dimensional digital image correlation

    Directory of Open Access Journals (Sweden)

    H. Munoz

    2017-08-01

    Full Text Available The complete stress–strain characteristics of sandstone specimens were investigated in a series of quasi-static monotonic uniaxial compression tests. Strain patterns development during pre- and post-peak behaviours in specimens with different aspect ratios was also examined. Peak stress, post-peak portion of stress–strain, brittleness, characteristics of progressive localisation and field strain patterns development were affected at different extents by specimen aspect ratio. Strain patterns of the rocks were obtained by applying three-dimensional (3D digital image correlation (DIC technique. Unlike conventional strain measurement using strain gauges attached to specimen, 3D DIC allowed not only measuring large strains, but more importantly, mapping the development of field strain throughout the compression test, i.e. in pre- and post-peak regimes. Field strain development in the surface of rock specimen suggests that strain starts localising progressively and develops at a lower rate in pre-peak regime. However, in post-peak regime, strains increase at different rates as local deformations take place at different extents in the vicinity and outside the localised zone. The extent of localised strains together with the rate of strain localisation is associated with the increase in rate of strength degradation. Strain localisation and local inelastic unloading outside the localised zone both feature post-peak regime.

  9. The impact of secondary-task type on the sensitivity of reaction-time based measurement of cognitive load for novices learning surgical skills using simulation.

    Science.gov (United States)

    Rojas, David; Haji, Faizal; Shewaga, Rob; Kapralos, Bill; Dubrowski, Adam

    2014-01-01

    Interest in the measurement of cognitive load (CL) in simulation-based education has grown in recent years. In this paper we present two pilot experiments comparing the sensitivity of two reaction time based secondary task measures of CL. The results suggest that simple reaction time measures are sensitive enough to detect changes in CL experienced by novice learners in the initial stages of simulation-based surgical skills training.

  10. The surgical management of the rheumatoid spine: Has the evolution of surgical intervention changed outcomes?

    Directory of Open Access Journals (Sweden)

    Robin Bhatia

    2014-01-01

    Full Text Available Context: Surgery for the rheumatoid cervical spine has been shown to stabilize the unstable spine; arrest/improve the progression of neurological deficit, help neck pain, and possibly decelerate the degenerative disease process. Operative intervention for the rheumatoid spine has significantly changed over the last 30 years. Aims: The purpose of this study was to review all cases of cervical rheumatoid spine requiring surgical intervention in a single unit over the last 30 years. Materials and Methods: A prospectively-maintained spine database was retrospectively searched for all cases of rheumatoid spine, leading to a review of indications, imaging, Ranawat and Myelopathy Disability Index measures, surgical morbidity, and survival curve analysis. Results: A total of 224 cases were identified between 1981 and 2011. Dividing the data into three time-epochs, there has been a significant increase in the ratio of segment-saving Goel-Harms C1-C2: Occipitocervical fixation (OCF surgery and survival has increased between 1981 and 2011 from 30% to 51%. Patients undergoing C1-C2 fixation were comparatively less myelopathic and in a better Ranawat class preoperatively, but postoperative outcome measures were well-preserved with favorable mortality rates over mean 39.6 months of follow-up. However, 11% of cases required OCF at mean 28 months post-C1-C2 fixation, largely due to instrumentation failure (80%. Conclusion: We present the largest series of surgically managed rheumatoid spines, revealing comparative data on OCF and C1-C2 fixation. Although survival has improved over the last 30 years, there have been changes in medical, surgical and perioperative management over that period of time too confounding the interpretation; however, the analysis presented suggests that rheumatoid patients presenting early in the disease process may benefit from C1 to C2 fixation, albeit with a proportion requiring OCF at a later time.

  11. Molecular markers: Implications for cytopathology and specimen collection.

    Science.gov (United States)

    VanderLaan, Paul A

    2015-08-01

    Cytologic specimens obtained through minimally invasive biopsy techniques are increasingly being used as principle diagnostic specimens for tumors arising in multiple sites. The number and scope of ancillary tests performed on these specimens have grown substantially over the past decade, including many molecular markers that not only can aid in formulating accurate and specific diagnoses but also can provide prognostic or therapeutic information to help direct clinical decisions. Thus, the cytopathologist needs to ensure that adequate material is collected and appropriately processed for the study of relevant molecular markers, many of which are specific to tumor site. This brief review covers considerations for effective cytologic specimen collection and processing to ensure diagnostic and testing success. In addition, a general overview is provided of molecular markers pertinent to tumors from a variety of sites. The recognition of these established and emerging molecular markers by cytopathologists is an important step toward realizing the promise of personalized medicine. © 2015 American Cancer Society.

  12. Effectiveness of preventative and other surgical measures on hypocalcemia following bilateral thyroid surgery: a systematic review and meta-analysis.

    Science.gov (United States)

    Antakia, Ramez; Edafe, Ovie; Uttley, Lesley; Balasubramanian, Saba P

    2015-01-01

    A variety of measures have been proposed to reduce the incidence of post-thyroidectomy hypocalcemia. The aim of this study was to perform a systematic review and meta-analysis of preventive and other surgical measures on post-thyroidectomy hypocalcemia as reported in the literature. Comprehensive searches of the PubMed, EMBASE, and Cochrane databases were performed, and the quality of included papers was assessed using the Cochrane risk of bias tool or a modified Newcastle-Ottawa Scale (NOS). The results of all included studies were summarized, and meta-analyses were performed where appropriate. Thirty-nine randomized controlled trials (RCTs) and 37 observational studies were included. Measures studied included hemostatic techniques, extent of thyroidectomy and central neck dissection, surgical approach, calcium/vitamin D/thiazide diuretic supplements, parathyroid gland autotransplantation (PGAT) and intraoperative parathyroid gland (PG) identification, truncal ligation of inferior thyroid artery (ITA), preoperative magnesium infusion, and use of magnification loupes and Surgicel. Measures associated with significantly lower rates of transient hypocalcemia in meta-analysis were postoperative calcium and vitamin D supplementation compared to either calcium supplements alone (odds ratio (OR) 0.66; p=0.04) or no supplements (OR 0.34; p=0.007), and bilateral subtotal thyroidectomy (BST) compared to Hartley Dunhill (HD) procedure (OR 0.35; p=0.01). Meta-analyses did not demonstrate any measure to be significantly associated with a reduction in permanent hypocalcemia. This review identified postoperative calcium and vitamin D supplementation and bilateral subtotal thyroidectomy (over HD) as being effective in prevention of transient hypocalcemia. However, the majority of RCTs were of low quality, primarily due to a lack of blinding. The wide variability in study design, definitions of hypocalcemia, and methods of assessment prevented meaningful summation of results for

  13. Impact of Surgical Approach on Long-term Survival in Esophageal Adenocarcinoma Patients With or Without Neoadjuvant Chemoradiotherapy.

    Science.gov (United States)

    Noordman, Bo Jan; van Klaveren, David; van Berge Henegouwen, Mark I; Wijnhoven, Bas P L; Gisbertz, Suzanne S; Lagarde, Sjoerd M; van der Gaast, Ate; Hulshof, Maarten C C M; Biermann, Katharina; Steyerberg, Ewout W; van Lanschot, J Jan B

    2018-05-01

    To compare overall survival in patients with esophageal adenocarcinoma who underwent transhiatal esophagectomy (THE) with limited lymphadenectomy or transthoracic esophagectomy (TTE) with extended lymphadenectomy with or without neoadjuvant chemoradiotherapy (nCRT). The application of neoadjuvant therapy might change the association between the extent of lymphadenectomy and survival in patients with esophageal adenocarcinoma. This may influence the choice of surgical approach in patients treated with nCRT. Patients with potentially curable subcarinal esophageal adenocarcinoma treated with surgery alone or nCRT followed by surgery in 7 centers were included. The effect of surgical approach on overall survival, differentiated by the addition or omission of nCRT, was analyzed using a multivariable Cox regression model that included well-known prognostic factors and factors that might have influenced the choice of surgical approach. In total, 701 patients were included, of whom 318 had TTE with extended lymphadenectomy and 383 had THE with limited lymphadenectomy. TTE had differential effects on survival (P for interaction = 0.02), with a more favorable prognostic effect in patients who were treated with surgery alone [hazard ratio (HR) = 0.77, 95% confidence interval (CI) 0.58-1.03]. This association was statistically significant in a subgroup of patients with 1 to 8 positive lymph nodes in the resection specimen (HR = 0.62, 95% CI 0.43-0.90). The favorable prognostic effect of TTE over THE was absent in the nCRT and surgery group (HR = 1.16, 95% CI 0.80-1.66) and in the subgroup of nCRT patients with 1 to 8 positive lymph nodes in the resection specimen (HR = 1.00, 95% CI 0.61-1.68). Compared to surgery alone, the addition of nCRT may reduce the need for TTE with extended lymphadenectomy to improve long-term survival in patients with esophageal adenocarcinoma.

  14. Laboratory specimens and genetic privacy: evolution of legal theory.

    Science.gov (United States)

    Lewis, Michelle Huckaby

    2013-03-01

    Although laboratory specimens are an important resource for biomedical research, controversy has arisen when research has been conducted without the knowledge or consent of the individuals who were the source of the specimens. This paper summarizes the most important litigation regarding the research use of laboratory specimens and traces the evolution of legal theory from property claims to claims related to genetic privacy interests. © 2013 American Society of Law, Medicine & Ethics, Inc.

  15. Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites - thermographic analysis on bovine ribs.

    Science.gov (United States)

    Marković, Aleksa; Lazić, Zoran; Mišić, Tijana; Šćepanović, Miodrag; Todorović, Aleksandar; Thakare, Kaustubh; Janjić, Bojan; Vlahović, Zoran; Glišić, Mirko

    2016-08-01

    During drilling implant sites, mechanical energy is converted into thermal one resulting in transient rise in temperature of surrounding bone. The temperature of 47°C exeeding one minute impairs osseointegration, compromises mechanical properties of the local bone and could cause early implant failure. This in vitro study aimed to assess the effect of surgical drill guide and temperature of irrigans on thermal changes of the local bone during drilling implant sites, and to test the influence of irrigans temperature on the temperature of surgical drill guide. A total of 48 specimens obtained from bovine ribs were randomly allocated to four experimental conditions according to the 2 x 2 factorial design: drill guide (with or without) and saline (at 25°C or 5°C). Real-time infrared thermography was used as a method for temperature measurement. The primary outcome was bone temperature change during drilling implant sites measured at 3 osteotomy depths, whereas the second one was change in the temperature of the drill guide. Data were analyzed by Brunner and Langer nonparametric analysis and Wilcoxon test. The effect of drill guide on the changes of bone temperature was significant at the entrance of osteotomy, whereas the effect of saline temperature was significant at all osteotomy levels (p 0.05). Guided surgery and irrigation with saline at 25°C were associated with the highest bone temperature increase. Increase in drill guide temperature was significantly higher when saline at 25°C was used (p < 0.001). Guided implant site preparation generates higher temperature of the local bone than conventional drilling, not exceeding the threshold for thermal bone necrosis. Although saline at room temperature provides sufficient heat control during drilling, cooled saline is more effective regardless the use of surgical drill guide.

  16. Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites - thermographic analysis on bovine ribs

    Directory of Open Access Journals (Sweden)

    Marković Aleksa

    2016-01-01

    Full Text Available Background/Aim. During drilling implant sites, mechanical energy is converted into thermal one resulting in transient rise in temperature of surrounding bone. The temperature of 47°C exeeding one minute impairs osseointegration, compromises mechanical properties of the local bone and could cause early implant failure. This in vitro study aimed to assess the effect of surgical drill guide and temperature of irrigans on thermal changes of the local bone during drilling implant sites, and to test the influence of irrigans temperature on the temperature of surgical drill guide. Methods. A total of 48 specimens obtained from bovine ribs were randomly allocated to four experimental conditions according to the 2 x 2 factorial design: drill guide (with or without and saline (at 25°C or 5°C. Real-time infrared thermography was used as a method for temperature measurement. The primary outcome was bone temperature change during drilling implant sites measured at 3 osteotomy depths, whereas the second one was change in the temperature of the drill guide. Data were analyzed by Brunner and Langer nonparametric analysis and Wilcoxon test. Results. The effect of drill guide on the changes of bone temperature was significant at the entrance of osteotomy, whereas the effect of saline temperature was significant at all osteotomy levels (p 0.05. Guided surgery and irrigation with saline at 25°C were associated with the highest bone temperature increase. Increase in drill guide temperature was significantly higher when saline at 25°C was used (p < 0.001. Conclusion. Guided implant site preparation generates higher temperature of the local bone than conventional drilling, not exceeding the threshold for thermal bone necrosis. Although saline at room temperature provides sufficient heat control during drilling, cooled saline is more effective regardless the use of surgical drill guide.

  17. 50 CFR 31.11 - Donation and loan of wildlife specimens.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Donation and loan of wildlife specimens... of Wildlife Reduction and Disposal § 31.11 Donation and loan of wildlife specimens. Wildlife specimens may be donated or loaned to public institutions for specific purposes. Donation or loans of...

  18. An Evaluation of Preparedness, Delivery and Impact of Surgical and Anesthesia Care in Madagascar: A Framework for a National Surgical Plan.

    Science.gov (United States)

    Bruno, Emily; White, Michelle C; Baxter, Linden S; Ravelojaona, Vaonandianina Agnès; Rakotoarison, Hasiniaina Narindria; Andriamanjato, Hery Harimanitra; Close, Kristin L; Herbert, Alison; Raykar, Nakul; Saluja, Saurabh; Shrime, Mark G

    2017-05-01

    The Lancet Commission on Global Surgery (LCoGS) described the lack of access to safe, affordable, timely surgical, and anesthesia care. It proposed a series of 6 indicators to measure surgery, accompanied by time-bound targets and a template for national surgical planning. To date, no sub-Saharan African country has completed and published a nationwide evaluation of its surgical system within this framework. Mercy Ships, in partnership with Harvard Medical School and the Madagascar Ministry of Health, collected data on the 6 indicators from 22 referral hospitals in 16 out of 22 regions of Madagascar. Data collection was by semi-structured interviews with ministerial, medical, laboratory, pharmacy, and administrative representatives in each region. Microsimulation modeling was used to calculate values for financial indicators. In Madagascar, 29% of the population can access a surgical facility within 2 h. Surgical workforce density is 0.78 providers per 100,000 and annual surgical volume is 135-191 procedures per 100,000 with a perioperative mortality rate of 2.5-3.3%. Patients requiring surgery have a 77.4-86.3 and 78.8-95.1% risk of incurring impoverishing and catastrophic expenditure, respectively. Of the six LCoGS indicator targets, Madagascar meets one, the reporting of perioperative mortality rate. Compared to the LCoGS targets, Madagascar has deficits in surgical access, workforce, volume, and the ability to offer financial risk protection to surgical patients. Its perioperative mortality rate, however, appears better than in comparable countries. The government is committed to improvement, and key stakeholder meetings to create a national surgical plan have begun.

  19. Drone Transport of Microbes in Blood and Sputum Laboratory Specimens.

    Science.gov (United States)

    Amukele, Timothy K; Street, Jeff; Carroll, Karen; Miller, Heather; Zhang, Sean X

    2016-10-01

    Unmanned aerial vehicles (UAVs) could potentially be used to transport microbiological specimens. To examine the impact of UAVs on microbiological specimens, blood and sputum culture specimens were seeded with usual pathogens and flown in a UAV for 30 ± 2 min. Times to recovery, colony counts, morphologies, and matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS)-based identifications of the flown and stationary specimens were similar for all microbes studied. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  20. Surgeon-tool force/torque signatures--evaluation of surgical skills in minimally invasive surgery.

    Science.gov (United States)

    Rosen, J; MacFarlane, M; Richards, C; Hannaford, B; Sinanan, M

    1999-01-01

    The best method of training for laparoscopic surgical skills is controversial. Some advocate observation in the operating room, while others promote animal and simulated models or a combination of surgical related tasks. The mode of proficiency evaluation common to all of these methods has been subjective evaluation by a skilled surgeon. In order to define an objective means of evaluating performance, an instrumented laparoscopic grasper was developed measuring the force/torque at the surgeon hand/tool interface. The measured database demonstrated substantial differences between experienced and novice surgeon groups. Analyzing forces and torques combined with the state transition during surgical procedures allows an objective measurement of skill in MIS. Teaching the novice surgeon to limit excessive loads and improve movement efficiency during surgical procedures can potentially result in less injury to soft tissues and less wasted time during laparoscopic surgery. Moreover the force/torque database measured in this study may be used for developing realistic virtual reality simulators and optimization of medical robots performance.

  1. Preoperative oral antibiotics reduce surgical site infection following elective colorectal resections.

    Science.gov (United States)

    Cannon, Jamie A; Altom, Laura K; Deierhoi, Rhiannon J; Morris, Melanie; Richman, Joshua S; Vick, Catherine C; Itani, Kamal M F; Hawn, Mary T

    2012-11-01

    Surgical site infection is a major cause of morbidity after colorectal resections. Despite evidence that preoperative oral antibiotics with mechanical bowel preparation reduce surgical site infection rates, the use of oral antibiotics is decreasing. Currently, the administration of oral antibiotics is controversial and considered ineffective without mechanical bowel preparation. The aim of this study is to examine the use of mechanical bowel preparation and oral antibiotics and their relationship to surgical site infection rates in a colorectal Surgical Care Improvement Project cohort. This retrospective study used Veterans Affairs Surgical Quality Improvement Program preoperative risk and surgical site infection outcome data linked to Veterans Affairs Surgical Care Improvement Project and Pharmacy Benefits Management data. Univariate and multivariable models were performed to identify factors associated with surgical site infection within 30 days of surgery. This study was conducted in 112 Veterans Affairs hospitals. Included were 9940 patients who underwent elective colorectal resections from 2005 to 2009. The primary outcome measured was the incidence of surgical site infection. Patients receiving oral antibiotics had significantly lower surgical site infection rates. Those receiving no bowel preparation had similar surgical site infection rates to those who had mechanical bowel preparation only (18.1% vs 20%). Those receiving oral antibiotics alone had an surgical site infection rate of 8.3%, and those receiving oral antibiotics plus mechanical bowel preparation had a rate of 9.2%. In adjusted analysis, the use of oral antibiotics alone was associated with a 67% decrease in surgical site infection occurrence (OR=0.33, 95% CI 0.21-0.50). Oral antibiotics plus mechanical bowel preparation was associated with a 57% decrease in surgical site infection occurrence (OR=0.43, 95% CI 0.34-0.55). Timely administration of parenteral antibiotics (Surgical Care Improvement

  2. Quantifying the Influence of Lightning Strike Pressure Loading on Composite Specimen Damage

    Science.gov (United States)

    Foster, P.; Abdelal, G.; Murphy, A.

    2018-04-01

    Experimental work has shown that a component of lightning strike damage is caused by a mechanical loading. As the profile of the pressure loading is unknown a number of authors propose different pressure loads, varying in form, application area and magnitude. The objective of this paper is to investigate the potential contribution of pressure loading to composite specimen damage. This is achieved through a simulation study using an established modelling approach for composite damage prediction. The study examines the proposed shockwave loads from the literature. The simulation results are compared with measured test specimen damage examining the form and scale of damage. The results for the first time quantify the significance of pressure loading, demonstrating that although a pressure load can cause damage consistent with that measured experimentally, it has a negligible contribution to the overall scale of damage. Moreover the requirements for a pressure to create the damage behaviours typically witnessed in testing requires that the pressure load be within a very precise window of magnitude and loading area.

  3. Risk Factors and Predictive Model Development of Thirty-Day Post-Operative Surgical Site Infection in the Veterans Administration Surgical Population.

    Science.gov (United States)

    Li, Xinli; Nylander, William; Smith, Tracy; Han, Soonhee; Gunnar, William

    2018-04-01

    -specific models were developed with number of variables ranging from 9 to 21 and the C-index ranging from 0.63 to 0.81, indicating acceptable discrimination. The decile plot of predicted versus observed SSI rates showed strong calibration. Surgery specialty-specific risk factors of 30-day post-operative SSI rates have been identified for a variety of surgery specialties. Accurate SSI risk-predictive surgery specialty-specific SSI predictive models have been developed and validated for the VHA surgery population. These models can be used to develop optimal preventive measures for high-risk patients, patient-centered care planning, and surgical quality improvement.

  4. Feasibility Study of Laser Cutting for Fabrication of Tensile Specimen

    International Nuclear Information System (INIS)

    Jin, Y. G.; Baik, S. J.; Kim, G. S.; Heo, G. S.; Yoo, B. O.; Ahn, S. B.; Chun, Y. B.

    2015-01-01

    The specimen fabrication technique was established to machine the specimen from the irradiated materials. The wire cut EDM(electric discharge machine) was modified to fabricate the mechanical testing specimens from irradiated components and fuel claddings. The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated components and claddings interrupted the applying the electric current during the processing. However, zirconium oxide is protective against further corrosion as well as beneficial to mechanical strength for the tensile deformation of the cladding. Thus, it is important to fabricate the irradiated specimens without removal of oxide layer on the surface of the irradiated structural components and claddings. In the present study, laser cutting system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the feasibility of the laser cutting system was studied for the fabrication of various types of irradiated specimens in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser beam machining system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the dimensions were compared for the feasibility of the laser cutting system. The effect of surface oxide layer was also investigated for machining process of the zircaloy-4 fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer

  5. Feasibility Study of Laser Cutting for Fabrication of Tensile Specimen

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Y. G.; Baik, S. J.; Kim, G. S.; Heo, G. S.; Yoo, B. O.; Ahn, S. B.; Chun, Y. B. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    The specimen fabrication technique was established to machine the specimen from the irradiated materials. The wire cut EDM(electric discharge machine) was modified to fabricate the mechanical testing specimens from irradiated components and fuel claddings. The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated components and claddings interrupted the applying the electric current during the processing. However, zirconium oxide is protective against further corrosion as well as beneficial to mechanical strength for the tensile deformation of the cladding. Thus, it is important to fabricate the irradiated specimens without removal of oxide layer on the surface of the irradiated structural components and claddings. In the present study, laser cutting system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the feasibility of the laser cutting system was studied for the fabrication of various types of irradiated specimens in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser beam machining system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the dimensions were compared for the feasibility of the laser cutting system. The effect of surface oxide layer was also investigated for machining process of the zircaloy-4 fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer.

  6. Optimum Operating Room Environment for the Prevention of Surgical Site Infections.

    Science.gov (United States)

    Gaines, Sara; Luo, James N; Gilbert, Jack; Zaborina, Olga; Alverdy, John C

    Surgical site infections (SSI), whether they be incisional or deep, can entail major morbidity and death to patients and additional cost to the healthcare system. A significant amount of effort has gone into optimizing the surgical patient and the operating room environment to reduce SSI. Relevant guidelines and literature were reviewed. The modern practice of surgical antisepsis involves the employment of strict sterile techniques inside the operating room. Extensive guidelines are available regarding the proper operating room antisepsis as well as pre-operative preparation. The use of pre-operative antimicrobial prophylaxis has become increasingly prevalent, which also presents the challenge of opportunistic and nosocomial infections. Ongoing investigative efforts have brought about a greater appreciation of the surgical patient's endogenous microflora, use of non-bactericidal small molecules, and pre-operative microbial screening. Systematic protocols exist for optimizing the surgical sterility of the operating room to prevent SSIs. Ongoing research efforts aim to improve the precision of peri-operative antisepsis measures and personalize these measures to tailor the patient's unique microbial environment.

  7. Surgical smoke and ultrafine particles

    Directory of Open Access Journals (Sweden)

    Nowak Dennis

    2008-12-01

    Full Text Available Abstract Background Electrocautery, laser tissue ablation, and ultrasonic scalpel tissue dissection all generate a 'surgical smoke' containing ultrafine ( Methods To measure the amount of generated particulates in 'surgical smoke' during different surgical procedures and to quantify the particle number concentration for operation room personnel a condensation particle counter (CPC, model 3007, TSI Inc. was applied. Results Electro-cauterization and argon plasma tissue coagulation induced the production of very high number concentration (> 100000 cm-3 of particles in the diameter range of 10 nm to 1 μm. The peak concentration was confined to the immediate local surrounding of the production side. In the presence of a very efficient air conditioning system the increment and decrement of ultrafine particle occurrence was a matter of seconds, with accumulation of lower particle number concentrations in the operation room for only a few minutes. Conclusion Our investigation showed a short term very high exposure to ultrafine particles for surgeons and close assisting operating personnel – alternating with longer periods of low exposure.

  8. Validity of fracture toughness determined with small bend specimens

    International Nuclear Information System (INIS)

    Wallin, K.; Rintamaa, R.; Valo, M.

    1994-02-01

    This report considers the validity of fracture toughness estimates obtained with small bend specimens in relation to fracture toughness estimates obtained with large specimens. The study is based upon the analysis and comparison of actual test results. The results prove the validity of the fracture toughness determined based upon small bend specimens, especially when the results are only used to determine the fracture toughness transition temperature T o . In this case the possible error is typically less than 5 deg C and at most 10 deg C. It can be concluded that small bend specimens are very suitable for the estimation of fracture toughness in the case of brittle fracture, provided the results are corrected for statistical size effects. (orig.). (20 refs., 17 figs.)

  9. Comparison measure of natural radioactivity in environment specimen using HPGe and NaI(Tl) γ-ray spectrometer

    International Nuclear Information System (INIS)

    Zhou Chunlin; Han Feng; Li Tiantuo; Ma Wenyan; Di Yuming; Guo Huiping; Wu Yuelei

    2000-01-01

    The author reports the comparison results on natural radioactive nuclide contents of soil specimen from an uranium diggings with HPGe and NaI(Tl) γ-ray spectrometer. Relative method and athwart matrix method are used to analyze natural radioactive nuclide contents in samples of soil. The results are compared and are proven to be in accordance with each other

  10. Whole Slide Imaging Versus Microscopy for Primary Diagnosis in Surgical Pathology

    Science.gov (United States)

    Mukhopadhyay, Sanjay; Feldman, Michael D.; Abels, Esther; Ashfaq, Raheela; Beltaifa, Senda; Cacciabeve, Nicolas G.; Cathro, Helen P.; Cheng, Liang; Cooper, Kumarasen; Dickey, Glenn E.; Gill, Ryan M.; Heaton, Robert P.; Kerstens, René; Lindberg, Guy M.; Malhotra, Reenu K.; Mandell, James W.; Manlucu, Ellen D.; Mills, Anne M.; Mills, Stacey E.; Moskaluk, Christopher A.; Nelis, Mischa; Patil, Deepa T.; Przybycin, Christopher G.; Reynolds, Jordan P.; Rubin, Brian P.; Saboorian, Mohammad H.; Salicru, Mauricio; Samols, Mark A.; Sturgis, Charles D.; Turner, Kevin O.; Wick, Mark R.; Yoon, Ji Y.; Zhao, Po

    2018-01-01

    Most prior studies of primary diagnosis in surgical pathology using whole slide imaging (WSI) versus microscopy have focused on specific organ systems or included relatively few cases. The objective of this study was to demonstrate that WSI is noninferior to microscopy for primary diagnosis in surgical pathology. A blinded randomized noninferiority study was conducted across the entire range of surgical pathology cases (biopsies and resections, including hematoxylin and eosin, immunohistochemistry, and special stains) from 4 institutions using the original sign-out diagnosis (baseline diagnosis) as the reference standard. Cases were scanned, converted to WSI and randomized. Sixteen pathologists interpreted cases by microscopy or WSI, followed by a wash-out period of ≥4 weeks, after which cases were read by the same observers using the other modality. Major discordances were identified by an adjudication panel, and the differences between major discordance rates for both microscopy (against the reference standard) and WSI (against the reference standard) were calculated. A total of 1992 cases were included, resulting in 15,925 reads. The major discordance rate with the reference standard diagnosis was 4.9% for WSI and 4.6% for microscopy. The difference between major discordance rates for microscopy and WSI was 0.4% (95% confidence interval, −0.30% to 1.01%). The difference in major discordance rates for WSI and microscopy was highest in endocrine pathology (1.8%), neoplastic kidney pathology (1.5%), urinary bladder pathology (1.3%), and gynecologic pathology (1.2%). Detailed analysis of these cases revealed no instances where interpretation by WSI was consistently inaccurate compared with microscopy for multiple observers. We conclude that WSI is noninferior to microscopy for primary diagnosis in surgical pathology, including biopsies and resections stained with hematoxylin and eosin, immunohistochemistry and special stains. This conclusion is valid across a

  11. SurePath Specimens Versus ThinPrep Specimen Types on the COBAS 4800 Platform: High-Risk HPV Status and Cytology Correlation in an Ethnically Diverse Bronx Population.

    Science.gov (United States)

    Naeem, R C; Goldstein, D Y; Einstein, Mark H; Ramos Rivera, G; Schlesinger, K; Khader, S N; Suhrland, M; Fox, A S

    2017-08-01

    To compare the cytologic preparations of 130 cervical specimens (from women of various ethnicities at high risk for human papillomavirus [HPV] infection) using the SurePath (SP) collection system with specimens gathered using the ThinPrep (TP) system, as processed on the Cobas 4800 analyzer, to determine which collection method more accurately identifies HPV infection. In our prospective study, specimens were collected from 130 women of various ethnicities residing in or near Bronx County, NY. The SP-collected specimen was first processed for cytologic findings; if clinical HPV testing was requested on that specimen, it was tested using Hybrid Capture II (HC2) methodology. We tested the remnant SP-collected cell concentrate using the Cobas analyzer. Then, the TP-collected and SP-collected specimens were tested in the same run on that analyzer, and the results were compared. We also compared the results with the concurrent cytologic findings. The results were concordant for overall HR-HPV status in 93.8% of cases. Also, a statistically significant lower cycle threshold value was observed with Cobas testing of specimen concentrates tested via the BD SurePath Pap Test (P = .001), suggesting higher sensitivity compared with specimens tested via the ThinPrep Pap Test. Cobas 4800 HPV testing of SP-collected specimen concentrates yields comparable results to TP-collected specimen concentrates. Based on the limited data that we derived, SP collection may be a more favorable methodology than TP collection for HPV testing of individuals at high risk in our ethnically diverse, urban patient population. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  12. Surgical Findings and Outcomes in Premenopausal Breast Cancer Patients Undergoing Oophorectomy: A Multicenter Review From the Society of Gynecologic Surgeons Fellows Pelvic Research Network.

    Science.gov (United States)

    Harvey, Lara F B; Abramson, Vandana G; Alvarez, Jimena; DeStephano, Christopher; Hur, Hye-Chun; Lee, Katherine; Mattingly, Patricia; Park, Beau; Piszczek, Carolyn; Seifi, Farinaz; Stuparich, Mallory; Yunker, Amanda

    2018-01-01

    To describe the procedures performed, intra-abdominal findings, and surgical pathology in a cohort of women with premenopausal breast cancer who underwent oopherectomy. Multicenter retrospective chart review (Canadian Task Force classification II-3). Nine US academic medical centers participating in the Fellows' Pelvic Research Network (FPRN). One hundred twenty-seven women with premenopausal breast cancer undergoing oophorectomy between January 2013 and March 2016. Surgical castration. The mean patient age was 45.8 years. Fourteen patients (11%) carried a BRCA mutations, and 22 (17%) carried another germline or acquired mutation, including multiple variants of uncertain significance. There was wide variation in surgical approach. Sixty-five patients (51%) underwent pelvic washings, and 43 (35%) underwent concurrent hysterectomy. Other concomitant procedures included midurethral sling placement, appendectomy, and hysteroscopy. Three patients experienced complications (transfusion, wound cellulitis, and vaginal cuff dehiscence). Thirteen patients (10%) had ovarian pathology detected on analysis of the surgical specimen, including metastatic tumor, serous cystadenomas, endometriomas, and Brenner tumor. Eight patients (6%) had Fallopian tube pathology, including 3 serous tubal intraepithelial cancers. Among the 44 uterine specimens, 1 endometrial adenocarcinoma and 1 multifocal endometrial intraepithelial neoplasia were noted. Regarding the entire study population, the number of patients meeting our study criteria and seen by gynecologic surgeons in the FPRN for oophorectomy increased by nearly 400% from 2013 to 2015. Since publication of the Suppression of Ovarian Function Trial data, bilateral oophorectomy has been recommended for some women with premenopausal breast cancer to facilitate breast cancer treatment with aromatase inhibitors. These women may be at elevated risk for occult abdominal pathology compared with the general population. Gynecologic surgeons

  13. Influence of bleaching agents on surface roughness of sound or eroded dental enamel specimens.

    Science.gov (United States)

    Azrak, Birgül; Callaway, Angelika; Kurth, Petra; Willershausen, Brita

    2010-12-01

    The aim of the present in vitro study was to assess the effect of bleaching agents on eroded and sound enamel specimens. Enamel specimens prepared from human permanent anterior teeth were incubated with different bleaching agents containing active ingredients as 7.5 or 13.5% hydrogen peroxide or 35% carbamide peroxide, ranging in pH from 4.9 to 10.8. The effect of the tooth whitening agents on surface roughness was tested for sound enamel surfaces as well as for eroded enamel specimens. To provoke erosive damage, the enamel specimens were incubated for 10 hours with apple juice (pH = 3.4). Afterwards, pretreated and untreated dental slices were incubated with one of the bleaching agents for 10 hours. The surface roughness (R(a)) of all enamel specimens (N = 80) was measured using an optical profilometric device. A descriptive statistical analysis of the R(a) values was performed. The study demonstrated that exposure to an acidic bleaching agent (pH = 4.9) resulted in a higher surface roughness (p = 0.043) than treatment with a high peroxide concentration (pH = 6.15). If the enamel surface was previously exposed to erosive beverages, subsequent bleaching may enhance damage to the dental hard tissue. Bleaching agents with a high concentration of peroxide or an acidic pH can influence the surface roughness of sound or eroded enamel. © 2010, COPYRIGHT THE AUTHORS. JOURNAL COMPILATION © 2010, WILEY PERIODICALS, INC.

  14. MR imaging findings of painful type II accessory navicular bone: correlation with surgical and pathologic studies

    International Nuclear Information System (INIS)

    Choi, Yun Sun; Lee, Kyung Tai; Kim, Eun Kyung; Kang, Heung Sik

    2004-01-01

    To evaluate the MR imaging findings of painful type II accessory navicular bone and to correlate these with the surgical and pathologic findings. The MR images of 17 patients with medial foot pain and surgically proven type II accessory navicular abnormalities were reviewed. The changes of signal intensity in the accessory navicular, synchondrosis and adjacent soft tissue, the presence of synchondrosis widening, and posterior tibial tendon (PTT) pathology on the T1-weighted and fat-suppressed T2-weighted images were analyzed. The MR imaging findings were compared with the surgical and pathologic findings. The fat-suppressed T2-weighted images showed high signal intensity in the accessory navicular bones and synchondroses in all patients, and in the soft tissue in 11 (64.7%) of the 17 patients, as well as synchondrosis widening in 3 (17.6%) of the 17 patients. The MR images showed tendon pathology in 12 (75%) of the 16 patients with PTT dysfunction at surgery. The pathologic findings of 16 surgical specimens included areas of osteonecrosis with granulomatous inflammation, fibrosis and destruction of the cartilage cap. The MR imaging findings of painful type II accessory navicular bone are a persistent edema pattern in the accessory navicular bone and within the synchondrosis, indicating osteonecrosis, inflammation and destruction of the cartilage cap. Posterior tibial tendon dysfunction was clinically evident in most patients

  15. Measurement of fractional x-ray absorption for radiation attenuating surgical gloves

    International Nuclear Information System (INIS)

    Nagalakshmi, B.; Sawant, S.G.; Nair, C.P.R.; Joshi, V.D.

    2000-01-01

    It is essential to make use of lead gloves having 0.25 mm lead equivalence only for routine x-ray screening as stipulated by International Commission on Radiological Protection. Such surgical gloves which provide attenuation to the extent of one half value thickness for low energy are very useful for the present trend of special x-ray examinations which are on the increase

  16. NASA Biological Specimen Repository

    Science.gov (United States)

    McMonigal, K. A.; Pietrzyk, R. A.; Sams, C. F.; Johnson, M. A.

    2010-01-01

    The NASA Biological Specimen Repository (NBSR) was established in 2006 to collect, process, preserve and distribute spaceflight-related biological specimens from long duration ISS astronauts. This repository provides unique opportunities to study longitudinal changes in human physiology spanning may missions. The NBSR collects blood and urine samples from all participating ISS crewmembers who have provided informed consent. These biological samples are collected once before flight, during flight scheduled on flight days 15, 30, 60, 120 and within 2 weeks of landing. Postflight sessions are conducted 3 and 30 days after landing. The number of in-flight sessions is dependent on the duration of the mission. Specimens are maintained under optimal storage conditions in a manner that will maximize their integrity and viability for future research The repository operates under the authority of the NASA/JSC Committee for the Protection of Human Subjects to support scientific discovery that contributes to our fundamental knowledge in the area of human physiological changes and adaptation to a microgravity environment. The NBSR will institute guidelines for the solicitation, review and sample distribution process through establishment of the NBSR Advisory Board. The Advisory Board will be composed of representatives of all participating space agencies to evaluate each request from investigators for use of the samples. This process will be consistent with ethical principles, protection of crewmember confidentiality, prevailing laws and regulations, intellectual property policies, and consent form language. Operations supporting the NBSR are scheduled to continue until the end of U.S. presence on the ISS. Sample distribution is proposed to begin with selections on investigations beginning in 2017. The availability of the NBSR will contribute to the body of knowledge about the diverse factors of spaceflight on human physiology.

  17. Improving ED specimen TAT using Lean Six Sigma.

    Science.gov (United States)

    Sanders, Janet H; Karr, Tedd

    2015-01-01

    Lean and Six Sigma are continuous improvement methodologies that have garnered international fame for improving manufacturing and service processes. Increasingly these methodologies are demonstrating their power to also improve healthcare processes. The purpose of this paper is to discuss a case study for the application of Lean and Six Sigma tools in the reduction of turnaround time (TAT) for Emergency Department (ED) specimens. This application of the scientific methodologies uncovered opportunities to improve the entire ED to lab system for the specimens. This case study provides details on the completion of a Lean Six Sigma project in a 1,000 bed tertiary care teaching hospital. Six Sigma's Define, Measure, Analyze, Improve, and Control methodology is very similar to good medical practice: first, relevant information is obtained and assembled; second, a careful and thorough diagnosis is completed; third, a treatment is proposed and implemented; and fourth, checks are made to determine if the treatment was effective. Lean's primary goal is to do more with less work and waste. The Lean methodology was used to identify and eliminate waste through rapid implementation of change. The initial focus of this project was the reduction of turn-around-times for ED specimens. However, the results led to better processes for both the internal and external customers of this and other processes. The project results included: a 50 percent decrease in vials used for testing, a 50 percent decrease in unused or extra specimens, a 90 percent decrease in ED specimens without orders, a 30 percent decrease in complete blood count analysis (CBCA) Median TAT, a 50 percent decrease in CBCA TAT Variation, a 10 percent decrease in Troponin TAT Variation, a 18.2 percent decrease in URPN TAT Variation, and a 2-5 minute decrease in ED registered nurses rainbow draw time. This case study demonstrated how the quantitative power of Six Sigma and the speed of Lean worked in harmony to improve

  18. Development of laser plasma x-ray microscope for living hydrated biological specimens

    International Nuclear Information System (INIS)

    Kado, Masataka; Daido, Hiroyuki

    2005-01-01

    Investigating the structure and the function of life object performing advanced life activity becomes important. In order to investigate the life object, it is necessary to observe living specimens with high spatial resolution and high temporal resolution. Since laser plasma x-ray source has high brightness and short pulse duration, x-ray microscope with the laser plasma x-ray source makes possible to observe living specimens. Such as chromosomes, macrophages, bacterium, and so on have been observed by contact x-ray microscopy. The x-ray images obtained by indirect measurements such as the contact x-ray microscopy have difficulty to avoid artificial effect such as irregular due to developing process. Development of an x-ray microscope with laser plasma x-ray source is necessary to avoid such defects. (author)

  19. Instrument for measuring fuel cladding strain

    International Nuclear Information System (INIS)

    Billeter, T.R.

    1976-01-01

    Development work to provide instrumentation for the continuous measurement of strain of material specimens such as nuclear fuel cladding has shown that a microwave sensor and associated instrumentation hold promise. The cylindrical sensor body enclosing the specimen results in a coaxial resonator absorbing microwave energy at frequencies dependent upon the diameter of the specimen. Diametral changes of a microinch can be resolved with use of the instrumentation. Very reasonable values of elastic strain were measured at 75 0 F and 1000 0 F for an internally pressurized 20 percent C.W. 316 stainless steel specimen simulating nuclear fuel cladding. The instrument also indicated the creep strain of the same specimen pressurized at 6500 psi and at a temperature of 1000 0 F for a period of 700 hours. Although the indicated strain appears greater than actual, the sensor/specimen unit experienced considerable oxidation even though an inert gas purge persisted throughout the test duration. By monitoring at least two modes of resonance, the measured strain was shown to be nearly independent of sensor temperature. To prevent oxidation, a second test was performed in which the specimen/sensor units were contained in an evacuated enclosure. The strain of the two prepressurized specimens as indicated by the microwave instrumentation agreed very closely with pre- and post-test measurements obtained with use of a laser interferometer

  20. Corrosion of Steel in Concrete – Specimen Design for Investigation of Interface and Bulk Conversions during Curing and Exposure

    DEFF Research Database (Denmark)

    Küter, Andre; Møller, Per; Geiker, Mette Rica

    2005-01-01

    A reinforced mortar specimen that allows electromotive force (EMF) measurements and electrochemical impedance spectroscopy (EIS) was designed and tested. The specimen consists of a mortar cylinder with a central rebar and a concentric arrangement of embedded electrode wires. The wires can act...... as both reference and counter electrode during EIS and the arrangement allows investigation of local changes in the bulk mortar by measuring the EMF of each wire versus an external standard electrode. The state of corrosion of the rebar can be investigated by EIS and EMF. EIS can be performed before...

  1. Specimen's plane misaligned installation solution based on charge fluctuation inside SEM

    Science.gov (United States)

    Lu, Haojian; Liu, Yanting; Yang, Yuanyuan; Wang, Panbing; Shen, Yajing

    2018-04-01

    Precise specimen's installation is a sticking point to ensure the characterization accuracy of the in-situ material property test. Although it is common knowledge that specimen's plane misaligned installation (PMI) would cause extra force loading during mechanical testing, there are few effective solutions available to deal with it at the current stage, especially during the in-situ scanning electron microscopy (SEM) test. Taking into consideration the charge fluctuation phenomenon under SEM, this paper proposes a highlight area variation (HAV) method for specimen deformation judgment, i.e., the specimen deformation is defined when the highlight area changes greater than 20% of the initial value of the specimen surface. Three types of specimens with different resistivities, i.e., human hair (electrical resistivity ˜3 × 1012 Ω cm), optical fiber (electrical resistivity ˜1017 Ω cm), and magnetic wire (electrical resistivity ˜2 × 10-5 Ω cm), are chosen to verify the effectiveness of the HAV method. Furthermore, combined with the developed robot-aided alignment system, the specimen's PMI problem can also be solved. In the demonstration, the human hair specimen is installed across two specimen stages and its in-situ twisting (in 360°) test is implemented. The results clearly indicate that the HAV method and the robot-aided alignment system are practical and reliable, and the specimen can be aligned on the same plane and installed precisely with accuracy up to 3 μm. This method will benefit the in-situ SEM material mechanical property test and has a significant impact in fundamental material research.

  2. Surgical Anatomy of the Cervical Part of the Hypoglossal Nerve.

    Science.gov (United States)

    Kariuki, Brian Ngure; Butt, Fawzia; Mandela, Pamela; Odula, Paul

    2018-03-01

    Iatrogenic injuries to cranial nerves, half of which affect the hypoglossal nerve, occur in up to 20% of surgical procedures involving the neck. The risk of injury could be minimized by in-depth knowledge of its positional and relational anatomy. Forty-one hypoglossal nerves were dissected from cadaveric specimens and positions described in relation to the internal carotid artery (ICA), external carotid artery (ECA), carotid bifurcation, mandible, hyoid bone, mastoid process, and the digastric tendon. The distance of the nerve from where it crossed the ICA and ECA to the carotid bifurcation was 29.93 (±5.99) mm and 15.19 (±6.68) mm, respectively. The point where it crossed the ICA was 12.24 (±3.71) mm superior to the greater horn of hyoid, 17.16 (±4.40) mm inferior to the angle of the mandible, and 39.08 (±5.69) mm from tip of the mastoid. The hypoglossal nerve loop was inferior to the digastric tendon in 73% of the cases. The hypoglossal nerves formed high loops in this study population. Caution should be exercised during surgical procedures in the neck. The study also revealed that the mastoid process is a reliable fixed landmark to locate the hypoglossal nerve.

  3. Impact of the Surgical Research Methodology Program on surgical residents' research profiles.

    Science.gov (United States)

    Farrokhyar, Forough; Amin, Nalin; Dath, Deepak; Bhandari, Mohit; Kelly, Stephan; Kolkin, Ann M; Gill-Pottruff, Catherine; Skot, Martina; Reid, Susan

    2014-01-01

    To evaluate whether implementing the formal Surgical Research Methodology (SRM) Program in the surgical residency curriculum improved research productivity compared with the preceding informal Research Seminar Series (RSS). The SRM Program replaced the RSS in July 2009. In the SRM Program, the curriculum in Year-1 consisted of 12 teaching sessions on the principles of clinical epidemiology and biostatistics, whereas the focus in Year-2 was on the design, conduct, and presentation of a research project. The RSS consisted of 8 research methodology sessions repeated annually for 2 years along with the design, conduct, and presentation of a research project. Research productivity was measured as the number of peer-reviewed publications and the generation of studies with higher levels of evidence. Outcome measures were independently assessed by 2 authors to avoid bias. Student t test and chi-square test were used for the analysis. Frequencies, mean differences with 95% CI, and effect sizes have been reported. In this study, 81 SRM residents were compared with 126 RSS residents. The performance of the SRM residents was superior on all metrics in our evaluation. They were significantly more productive and published more articles than the RSS residents (mean difference = 1.0 [95% CI: 0.5-1.5], p research performance improved 11.0 grades (95% CI: 8.5%-13.5%, p research methodology is crucial to appropriately apply evidence-based findings in clinical practice. The SRM Program has significantly improved the research productivity and performance of the surgical residents from all disciplines. The implementation of a similar research methodology program is highly recommended for the benefit of residents' future careers and ultimately, evidence-based patient care. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  4. ANTIMICROBIAL SUSCEPTIBILITY PATTERN OF ORGANISMS CAUSING SURGICAL SITE INFECTIONS (SSI

    Directory of Open Access Journals (Sweden)

    Rohini Murlidhar Gajbhiye

    2017-02-01

    Full Text Available BACKGROUND CDC defines surgical site infection as ‘Infections related to operative procedure that occurs at or near surgical incision within 30 days of operative procedure or within one year if the implant is left in situ’. Surgical site infection (SSI is 3 rd most frequently reported nosocomial infection (12%-16% as per National Nosocomial Infection Surveillance (NNIS. The aim of this study was to investigate the antimicrobial susceptibility pattern of organisms causing SSI. MATERIALS AND METHODS During a two year study period in a tertiary care hospital, 19,127 patients underwent surgeries in various surgical departments. Of these 517 (2.7% developed surgical site infection. The surgical wounds were classified by CDC & NNIS criteria into 4 classes. Two wound swabs were taken and processed by standard microbiological techniques. Antimicrobial susceptibility along with testing of ESBLs, MBLs, AmpCβ lactamases was done for all isolates causing SSI. RESULTS Among 19,127 patients, 517 (2.7% developed SSI. It was highest in patients of perforation peritonitis (11.99%.Among 517 specimens, 340 (65.76% showed growth and 177 (34.23% were culture negative. E.coli (23.33% was the commonest organism isolated followed by Acinetobacter spp. (16%, Klebsiella spp. (15.66%, Pseudomonas spp. (15.33%, S. aureus (10.33%, S. epidermidis(7.3%, Proteus spp. (6.00% and Citrobacter spp. (2.66%.Staphylococcus spp. were 100 % sensitive to Vancomycin & Linezolid. (27.5% S. aureus were MRSA and (17.5% were Inducible Clindamycin resistant (ICR. Enterobacteriaceae isolates showed maximum sensitivity towards Imipenem, Piperacillin-Tazobactam and Amikacin. Klebsiella spp. (40.62%, E.coli (35.89%, Citrobacter spp. (33.33%, Proteus spp. (26.08% were ESBL producers. Klebsiella spp. (17.18%, E.coli (10.25%, Proteus spp. (11.11% and Citrobacter spp. (8.69% were AmpC producers. Acinetobacter spp. (28.57% was commonest MBL producer followed by Klebsiella spp. (20

  5. Fracture mechanics characterisation of medium-size adhesive joint specimens

    DEFF Research Database (Denmark)

    Sørensen, Bent F.; Jacobsen, T.K.

    2004-01-01

    Medium-size specimens (glass-fibre beams bonded together by an adhesive layer were tested in four point bending to determine their load carrying capacity. Specimens having different thickness were tested. Except for onespecimen, the cracking occurred as cracking...... along the adhesive layer; initially cracking occurred along the adhesive/laminate interface, but after some crack extension the cracking took place inside the laminate (for one specimen the later part of thecracking occurred unstably along the adhesive/ laminate interface). Crack bridging by fibres...

  6. A proposed standard round compact specimen for plane strain fracture toughness testing

    Science.gov (United States)

    Underwood, J. H.; Newman, J. C., Jr.; Seeley, R. R.

    1980-01-01

    A round, disk-shaped specimen is proposed as a standard test specimen for addition to ASTM Test for Plane-Strain Fracture Toughness of Metallic Materials (E 399-78A). The specimen is diametrically cracked, and loaded in the same way as the existing standard compact specimen. Tests and analyses were performed to verify that the proposed round compact specimen and associated stress intensity factor K solution are appropriate for a standard plane strain fracture toughness test. The use of the round compact specimen for other fracture tests is described.

  7. Open surgical simulation--a review.

    Science.gov (United States)

    Davies, Jennifer; Khatib, Manaf; Bello, Fernando

    2013-01-01

    Surgical simulation has benefited from a surge in interest over the last decade as a result of the increasing need for a change in the traditional apprentice model of teaching surgery. However, despite the recent interest in surgical simulation as an adjunct to surgical training, most of the literature focuses on laparoscopic, endovascular, and endoscopic surgical simulation with very few studies scrutinizing open surgical simulation and its benefit to surgical trainees. The aim of this review is to summarize the current standard of available open surgical simulators and to review the literature on the benefits of open surgical simulation. Open surgical simulators currently used include live animals, cadavers, bench models, virtual reality, and software-based computer simulators. In the current literature, there are 18 different studies (including 6 randomized controlled trials and 12 cohort studies) investigating the efficacy of open surgical simulation using live animal, bench, and cadaveric models in many surgical specialties including general, cardiac, trauma, vascular, urologic, and gynecologic surgery. The current open surgical simulation studies show, in general, a significant benefit of open surgical simulation in developing the surgical skills of surgical trainees. However, these studies have their limitations including a low number of participants, variable assessment standards, and a focus on short-term results often with no follow-up assessment. The skills needed for open surgical procedures are the essential basis that a surgical trainee needs to grasp before attempting more technical procedures such as laparoscopic procedures. In this current climate of medical practice with reduced hours of surgical exposure for trainees and where the patient's safety and outcome is key, open surgical simulation is a promising adjunct to modern surgical training, filling the void between surgeons being trained in a technique and a surgeon achieving fluency in that

  8. Old Plants, New Tricks: Phenological Research Using Herbarium Specimens.

    Science.gov (United States)

    Willis, Charles G; Ellwood, Elizabeth R; Primack, Richard B; Davis, Charles C; Pearson, Katelin D; Gallinat, Amanda S; Yost, Jenn M; Nelson, Gil; Mazer, Susan J; Rossington, Natalie L; Sparks, Tim H; Soltis, Pamela S

    2017-07-01

    The timing of phenological events, such as leaf-out and flowering, strongly influence plant success and their study is vital to understanding how plants will respond to climate change. Phenological research, however, is often limited by the temporal, geographic, or phylogenetic scope of available data. Hundreds of millions of plant specimens in herbaria worldwide offer a potential solution to this problem, especially as digitization efforts drastically improve access to collections. Herbarium specimens represent snapshots of phenological events and have been reliably used to characterize phenological responses to climate. We review the current state of herbarium-based phenological research, identify potential biases and limitations in the collection, digitization, and interpretation of specimen data, and discuss future opportunities for phenological investigations using herbarium specimens. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Anxiety in veterinary surgical students

    DEFF Research Database (Denmark)

    Langebæk, Rikke; Eika, Berit; Jensen, Asger Lundorff

    2012-01-01

    The surgical educational environment is potentially stressful and this can negatively affect students' learning. The aim of this study was to investigate whether veterinary students' level of anxiety is higher in a surgical course than in a non-surgical course and if pre-surgical training...... in a Surgical Skills Lab (SSL) has an anxiety reducing effect. Investigations were carried out as a comparative study and a parallel group study. Potential participants were fourth-year veterinary students who attended a surgical course (Basic Surgical Skills) and a non-surgical course (Clinical Examination...... and 28 students from 2010). Our results show that anxiety levels in veterinary students are significantly higher in a surgical course than in a non-surgical course (p...

  10. The Virtual Surgical Pelvis : Anatomy Visualization for Education and Surgical Planning

    NARCIS (Netherlands)

    Smit, N.N.

    2016-01-01

    This thesis deals with visualizing anatomical data for medical education and surgical planning purposes. To this end, we have developed a detailed virtual atlas, the Virtual Surgical Pelvis (VSP),which unifies surgically relevant knowledge on pelvic anatomy. We provide methods to share the knowledge

  11. Design of four-point SENB specimens with stable crack growth

    DEFF Research Database (Denmark)

    Jørgensen, Jeppe Bjørn; Kildegaard, Casper; Sørensen, Bent F.

    2018-01-01

    A four-point single-edge-notch-beam (SENB) test specimen loaded in displacement control (fixed grip) is proposed for studying crack deflection at bi-material interfaces. In order to ensure stable crack growth, a novel analytical model of the four-point SENB specimen in fixed grip is derived...... and compared with numerical models. Model results show that the specimen should be short and thick, and the start-crack length should be deep for the crack to propagate stable towards the bi-material interface. Observations from experimental tests of four-point SENB specimens with different start-crack lengths...

  12. Deriving DICOM surgical extensions from surgical workflows

    Science.gov (United States)

    Burgert, O.; Neumuth, T.; Gessat, M.; Jacobs, S.; Lemke, H. U.

    2007-03-01

    The generation, storage, transfer, and representation of image data in radiology are standardized by DICOM. To cover the needs of image guided surgery or computer assisted surgery in general one needs to handle patient information besides image data. A large number of objects must be defined in DICOM to address the needs of surgery. We propose an analysis process based on Surgical Workflows that helps to identify these objects together with use cases and requirements motivating for their specification. As the first result we confirmed the need for the specification of representation and transfer of geometric models. The analysis of Surgical Workflows has shown that geometric models are widely used to represent planned procedure steps, surgical tools, anatomical structures, or prosthesis in the context of surgical planning, image guided surgery, augmented reality, and simulation. By now, the models are stored and transferred in several file formats bare of contextual information. The standardization of data types including contextual information and specifications for handling of geometric models allows a broader usage of such models. This paper explains the specification process leading to Geometry Mesh Service Object Pair classes. This process can be a template for the definition of further DICOM classes.

  13. Factors That Influence Surgical Margin State in Patients Undergoing Cold Knife Conization - A Single Center Experience.

    Science.gov (United States)

    Aluloski, Igor; Tanturovski, Mile; Petrusevska, Gordana; Jovanovic, Rubens; Kostadinova-Kunovska, Slavica

    2017-12-01

    To evaluate the factors that influence the surgical margin state in patients undergoing cold knife conization at the University Clinic of Gynecology and Obstetrics in Skopje, Republic of Macedonia Materials and methods: We have retrospectively analyzed the medical records of all patients that underwent a cold knife conization at our Clinic in 2015. We cross-referenced the surgical margin state with the histopathological diagnosis (LSIL, HSIL or micro-invasive/invasive cancer), menopausal status of the patients, number of pregnancies, surgeon experience, operating time and cone depth. The data was analyzed with the Chi square test, Fisher's exact test for categorical data and Student's T test for continuous data and univariate and multivariate logistical regressions were performed. A total of 246 medical records have neen analyzed, out of which 29 (11.79%) patients had LSIL, 194 (78.86%) had HSIL and 23 (9.34%) patients suffered micro-invasive/invasive cervical cancer. The surgical margins were positive in 78 (31.7%) of the patients. The average age of the patients was 41.13 and 35 (14.23%) of the patients were menopausal. The multivariate logistic regression identified preoperative forceps biopsy of micro-invasive SCC, HSIL or higher cone specimen histology and shorter cone depth as independent predictors of surgical margin involvement in patients undergoing cold knife conization. In the current study, we have found no association between the inherent characteristics of the patient and the surgeon and the surgical margin state after a CKC. The most important predictors for positive margins were the severity of the lesion and the cone depth.

  14. Practices for Identifying and Rejecting Hemolyzed Specimens Are Highly Variable in Clinical Laboratories.

    Science.gov (United States)

    Howanitz, Peter J; Lehman, Christopher M; Jones, Bruce A; Meier, Frederick A; Horowitz, Gary L

    2015-08-01

    Hemolysis is an important clinical laboratory quality attribute that influences result reliability. To determine hemolysis identification and rejection practices occurring in clinical laboratories. We used the College of American Pathologists Survey program to distribute a Q-Probes-type questionnaire about hemolysis practices to Chemistry Survey participants. Of 3495 participants sent the questionnaire, 846 (24%) responded. In 71% of 772 laboratories, the hemolysis rate was less than 3.0%, whereas in 5%, it was 6.0% or greater. A visual scale, an instrument scale, and combination of visual and instrument scales were used to identify hemolysis in 48%, 11%, and 41% of laboratories, respectively. A picture of the hemolysis level was used as an aid to technologists' visual interpretation of hemolysis levels in 40% of laboratories. In 7.0% of laboratories, all hemolyzed specimens were rejected; in 4% of laboratories, no hemolyzed specimens were rejected; and in 88% of laboratories, some specimens were rejected depending on hemolysis levels. Participants used 69 different terms to describe hemolysis scales, with 21 terms used in more than 10 laboratories. Slight and moderate were the terms used most commonly. Of 16 different cutoffs used to reject hemolyzed specimens, moderate was the most common, occurring in 30% of laboratories. For whole blood electrolyte measurements performed in 86 laboratories, 57% did not evaluate the presence of hemolysis, but for those that did, the most common practice in 21 laboratories (24%) was centrifuging and visually determining the presence of hemolysis in all specimens. Hemolysis practices vary widely. Standard assessment and consistent reporting are the first steps in reducing interlaboratory variability among results.

  15. Enhanced Electrical Resistivity after Rapid Cool of the Specimen in Layered Oxide LixCoO2

    Science.gov (United States)

    Miyoshi, K.; Manami, K.; Takeuchi, J.; Sasai, R.; Nishigori, S.

    Measurements of electrical resistivity and DC magnetization for LixCoO2 (x=0.71 and 0.64) have been performed using single crystal specimens. It has been found that electrical resistivity measured after rapid cool of the specimen becomes larger compared with that after slow cool below the temperature TS∽155 K at which charge ordering of Co3+/Co4+(=2:1) occurs. The behavior can be understood considering that the charge ordering can be destroyed by Li ions which are in an amorphous state after rapid cool via the interlayer Coulomb interactions, and also that the disordered Co3+/Co4+ state becomes insulating, while the charge ordered state has a metallic electronic structure, as recently revealed by the scanning tunneling microscopy.

  16. Molecular detection of candida species from hospitalized patient’s specimens.

    Science.gov (United States)

    Camacho-Cardoso, José Luis; Martínez-Rivera, María Ángeles; Manzano-Gayosso, Patricia; Méndez-Tovar, Luis Javier; López-Martínez, Rubén; Hernández-Hernández, Francisca

    To identify the most frequent Candida species in specimens from patients hospitalized in different medical centers of Mexico City, with suspected fungal infection. Specimens were grown on Sabouraud dextrose agar at 28°C for 72 h. In addition, DNA was extracted. Isolates were grown on CHROMagar Candida™, at 37°C for 48 h. The molecular identification was performed by polymerase chain reaction (PCR) using primers specific for four species. Eighty one specimens were processed and included: bronchial lavage, pleural, cerebrospinal, peritoneal, ascites and bile fluids; blood, sputum, bone marrow, oro-tracheal cannula and ganglion. By culture, 30 samples (37%) were positive, and by PCR, 41 (50.6%). By PCR, the frequency of species was: Candida albicans 82.9%, Candida tropicalis 31.7%, Candida glabrata 24.4%, and Candida parapsilosis 4.9%. In 34.1% of specimens a species mixture was detected suggesting a co-infection: Two species in five specimens (C. albicans-C tropicalis and C. albicans-C glabrata), and three species in three specimens (C. albicans-C. glabrata-C. tropicalis). The PCR is an useful tool for detection the most common Candida species causing infection in hospitalized patients, it avoids the requirement of culture weather we start from clinical specimen and it favors the early diagnosis of invasive candidiasis. Copyright: © 2017 SecretarÍa de Salud

  17. Influence of side-groove root radius on the ductile fracture toughness of miniature C(T) specimens

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.; Scibetta, M.

    2009-05-15

    The use of miniature C(T) specimens, MC(T), for fracture toughness measurements in the upper shelf regime has been investigated at SCK-CEN since 2004, in the framework of the Electrabel/Tractebel SCK-CEN Convention (now General Framework Agreement SUEZ-SCK-CEN). This geometry has been used and validated on both unirradiated (2004-05) and irradiated (2006) materials, mainly reactor pressure vessel (RPV) steels. While side-grooved MC(T) specimens have shown in all conditions a systematically lower tearing resistance and ductile crack initiation toughness as compared to standard-size 1TC(T) samples, the only plain-sided MC(T) specimen tested in 2005 exhibited very high ductile fracture toughness, thus pointing at a strong influence of side-grooving on the upper shelf properties of MC(T) specimens. This study investigates the influence of side-grooving on the initiation toughness and tearing resistance of MC(T) specimens, as a function of the root radius of the side-groove (ranging from 0.1 to 1 mm) and in comparison with plain-sided MC(T) and reference 1TC(T) samples. The material used is the well characterized DIN 22NiMoCr37 RPV steel, which had been used in the European project which generated the famous EURO fracture toughness data set.

  18. Stress-deformed state of cylindrical specimens during indirect tensile strength testing

    Directory of Open Access Journals (Sweden)

    Levan Japaridze

    2015-10-01

    Full Text Available In this study, the interaction between cylindrical specimen made of homogeneous, isotropic, and linearly elastic material and loading jaws of any curvature is considered in the Brazilian test. It is assumed that the specimen is diametrically compressed by elliptic normal contact stresses. The frictional contact stresses between the specimen and platens are neglected. The analytical solution starts from the contact problem of the loading jaws of any curvature and cylindrical specimen. The contact width, corresponding loading angle (2θ0, and elliptical stresses obtained through solution of the contact problems are used as boundary conditions for a cylindrical specimen. The problem of the theory of elasticity for a cylinder is solved using Muskhelishvili's method. In this method, the displacements and stresses are represented in terms of two analytical functions of a complex variable. In the main approaches, the nonlinear interaction between the loading bearing blocks and the specimen as well as the curvature of their surfaces and the elastic parameters of their materials are taken into account. Numerical examples are solved using MATLAB to demonstrate the influence of deformability, curvature of the specimen and platens on the distribution of the normal contact stresses as well as on the tensile and compressive stresses acting across the loaded diameter. Derived equations also allow calculating the modulus of elasticity, total deformation modulus and creep parameters of the specimen material based on the experimental data of radial contraction of the specimen.

  19. The effect of intraoral suction on oxygen-enriched surgical environments: a mechanism for reducing the risk of surgical fires.

    Science.gov (United States)

    VanCleave, Andrea M; Jones, James E; McGlothlin, James D; Saxen, Mark A; Sanders, Brian J; Vinson, LaQuia A

    2014-01-01

    In this study, a mechanical model was applied in order to replicate potential surgical fire conditions in an oxygen-enriched environment with and without high-volume suction typical for dental surgical applications. During 41 trials, 3 combustion events were measured: an audible pop, a visible flash of light, and full ignition. In at least 11 of 21 trials without suction, all 3 conditions were observed, sometimes with an extent of fire that required early termination of the experimental trial. By contrast, in 18 of 20 with-suction trials, ignition did not occur at all, and in the 2 cases where ignition did occur, the fire was qualitatively a much smaller, candle-like flame. Statistically comparing these 3 combustion events in the no-suction versus with-suction trials, ignition (P = .0005), audible pop (P = .0211), and flash (P = .0092) were all significantly more likely in the no-suction condition. These results suggest a possible significant and new element to be added to existing surgical fire safety protocols toward making surgical fires the "never-events" they should be.

  20. Applicability of the Modified Ritchie-Knott-Rice Failure Criterion to Examine the Feasibility of Miniaturized Charpy Type SE(B Specimens

    Directory of Open Access Journals (Sweden)

    Toshiyuki Meshii

    2016-01-01

    Full Text Available This paper examined whether the modified Ritchie-Knott-Rice (RKR failure criterion can be applied to examine the feasibility of miniaturized Charpy type SE(B specimens of thickness-to-width ratio B/W=1. The modified RKR failure criterion considered in this paper is the (4δt,σ22c criterion which predicts the onset of cleavage fracture when the midplane crack-opening stress measured at a distance equal to four times the crack-tip opening displacement, denoted as σ22d, exceeds a critical stress σ22c. Specimens with B values of 25, 10, 3, and 2 mm (denoted as 25t, 10t, 3t, and 2t specimens, resp. manufactured with 0.55% carbon steel were tested at 20°C. The results showed that the modified RKR criterion could appropriately predict the occurrence of cleavage fracture accompanied by negligibly small stable crack extension (denoted as KJc fracture naturally for the 25t and 10t specimens. The modified RKR criterion could also predict that KJc fracture does not occur for the 2t specimen. The σ22c obtained from specimens for the 25t and 10t specimens exhibited only a small difference, indicating that the Jc obtained from the 10t specimens can be used to predict the Jc that will be obtained with the 25t specimens.

  1. Replacement of the rotary specimen rack in the U.S. Geological Survey TRIGA Reactor (GSTR)

    International Nuclear Information System (INIS)

    Rusling, D.H.; Helfer, P.G.; Perryman, R.E.; Smith, W.L.

    1986-01-01

    A new rotary specimen rack was installed in the GSTR on November 13, 1985. The new rack has been modified to allow the pneumatic unloading of samples. Instructions for the removal and installation of the rotary specimen rack were provided by GA Technologies. The first step was to prepare the core for removal of the control rods, T/C fuel elements, and the central thimble. The rack was weighted prior to removal to ensure that it could not float to the surface. The old rack was stored at the side of the tank. Radiation measurements were made with an underwater ion chamber. (author)

  2. Disposable surgical face masks for preventing surgical wound infection in clean surgery

    Directory of Open Access Journals (Sweden)

    Allyson Lipp

    Full Text Available BACKGROUND: Surgical face masks were originally developed to contain and filter droplets containing microorganisms expelled from the mouth and nasopharynx of healthcare workers during surgery, thereby providing protection for the patient. However, there are several ways in which surgical face masks could potentially contribute to contamination of the surgical wound, e.g. by incorrect wear or by leaking air from the side of the mask due to poor string tension. OBJECTIVES: To determine whether disposable surgical face masks worn by the surgical team during clean surgery prevent postoperative surgical wound infection. SEARCH METHODS: We searched The Cochrane Wounds Group Specialised Register (searched 14 September 2011; The Cochrane Central Register of Controlled Trials (CENTRAL (The Cochrane Library 2011, Issue 3; Ovid MEDLINE (2008 to August Week 5 2011; Ovid MEDLINE (In-Process &Other Non-Indexed Citations September 13, 2011; Ovid EMBASE (2008 to 2011 Week 35; and EBSCO CINAHL (2008 to 9 September 2011. SELECTION CRITERIA: Randomized controlled trials (RCTs and quasi-randomized controlled trials comparing the use of disposable surgical masks with the use of no mask. DATA COLLECTION AND ANALYSIS: Two review authors extracted data independently. MAIN RESULTS: Three trials were included, involving a total of 2113 participants. There was no statistically significant difference in infection rates between the masked and unmasked group in any of the trials. AUTHORS' CONCLUSIONS: From the limited results it is unclear whether the wearing of surgical face masks by members of the surgical team has any impact on surgical wound infection rates for patients undergoing clean surgery.

  3. On the crack propagation analysis of rock like Brazilian disc specimens containing cracks under compressive line loading

    Directory of Open Access Journals (Sweden)

    Hadi Haeri

    Full Text Available The pre-existing cracks in the brittle substances seem to be the main cause of their failure under various loading conditions. In this study, a simultaneous analytical, experimental and numerical analysis of crack propagation, cracks coalescence and failure process of brittle materials has been performed. Brazilian disc tests are being carried out to evaluate the cracks propagation paths in rock-like Brazilian disc specimens containing single and double cracks (using rock-like specimens which are specially prepared from Portland Pozzolana Cement (PPC, fine sands and water in a rock mechanics laboratory. The failure load of the pre-cracked disc specimens are measured showing the decreasing effects of the cracks and their orientation on the final failure load. The same specimens are numerically simulated by a higher order indirect boundary element method known as displacement discontinuity method. These numerical results are compared with the existing analytical and experimental results proving the accuracy and validity of the proposed numerical method. The numerical and experimental results obtained from the tested specimens are in good agreement and demonstrate the accuracy and effectiveness of the proposed approach.

  4. Specimen environments in thermal neutron scattering experiments

    International Nuclear Information System (INIS)

    Cebula, D.J.

    1980-11-01

    This report is an attempt to collect into one place outline information concerning the techniques used and basic design of sample environment apparatus employed in neutron scattering experiments. Preliminary recommendations for the specimen environment programme of the SNS are presented. The general conclusion reached is that effort should be devoted towards improving reliability and efficiency of operation of specimen environment apparatus and developing systems which are robust and easy to use, rather than achieving performance at the limits of technology. (author)

  5. Ultrastable gold substrates: Properties of a support for high-resolution electron cryomicroscopy of biological specimens

    Science.gov (United States)

    Russo, Christopher J.; Passmore, Lori A.

    2016-01-01

    Electron cryomicroscopy (cryo-EM) allows structure determination of a wide range of biological molecules and specimens. All-gold supports improve cryo-EM images by reducing radiation-induced motion and image blurring. Here we compare the mechanical and electrical properties of all-gold supports to amorphous carbon foils. Gold supports are more conductive, and have suspended foils that are not compressed by differential contraction when cooled to liquid nitrogen temperatures. These measurements show how the choice of support material and geometry can reduce specimen movement by more than an order of magnitude during low-dose imaging. We provide methods for fabrication of all-gold supports and preparation of vitrified specimens. We also analyse illumination geometry for optimal collection of high resolution, low-dose data. Together, the support structures and methods herein can improve the resolution and quality of images from any electron cryomicroscope. PMID:26592474

  6. Consistency of performance of robot-assisted surgical tasks in virtual reality.

    Science.gov (United States)

    Suh, I H; Siu, K-C; Mukherjee, M; Monk, E; Oleynikov, D; Stergiou, N

    2009-01-01

    The purpose of this study was to investigate consistency of performance of robot-assisted surgical tasks in a virtual reality environment. Eight subjects performed two surgical tasks, bimanual carrying and needle passing, with both the da Vinci surgical robot and a virtual reality equivalent environment. Nonlinear analysis was utilized to evaluate consistency of performance by calculating the regularity and the amount of divergence in the movement trajectories of the surgical instrument tips. Our results revealed that movement patterns for both training tasks were statistically similar between the two environments. Consistency of performance as measured by nonlinear analysis could be an appropriate methodology to evaluate the complexity of the training tasks between actual and virtual environments and assist in developing better surgical training programs.

  7. Experimental study on variations in Charpy impact energies of low carbon steel, depending on welding and specimen cutting method

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Zhaorui; Kang, Hansaem; Lee, Young Seog [Chung-Ang University, Seoul (Korea, Republic of)

    2016-05-15

    This paper presents an experimental study that examines variations of Charpy impact energy of a welded steel plate, depending upon the welding method and the method for obtaining the Charpy specimens. Flux cored arc welding (FCAW) and Gas tungsten arc welding (GTAW) were employed to weld an SA516 Gr. 70 steel plate. The methods of wire cutting and water-jet cutting were adopted to take samples from the welded plate. The samples were machined according to the recommendations of ASTM SEC. II SA370, in order to fit the specimen dimension that the Charpy impact test requires. An X-ray diffraction (XRD) method was used to measure the as-weld residual stress and its redistribution after the samples were cut. The Charpy impact energy of specimens was considerably dependent on the cutting methods and locations in the welded plate where the specimens were taken. The specimens that were cut by water jet followed by FCAW have the greatest resistance-to-fracture (Charpy impact energy). Regardless of which welding method was used, redistributed transverse residual stress becomes compressive when the specimens are prepared using water-jet cutting. Meanwhile, redistributed transverse residual stress becomes tensile when the specimens are prepared using wire cutting.

  8. The effect of thermal treatment on the mechanical properties of PLLA tubular specimens

    Directory of Open Access Journals (Sweden)

    Arbeiter Daniela

    2016-09-01

    Full Text Available Conventional permanent stent systems for vascular applications are associated with long-term risks, such as restenosis and thrombosis. To overcome these limitations, novel approaches using various biodegradable materials for stent construction have been investigated. In this context, thermal treatment of polymer materials is investigated to adjust the mechanical properties of biodegradable stents. In this work polymeric tubular specimens of biodegradable poly(L-lactide (PLLA were extruded and subjected to a molding process using different temperatures above glass transition temperature TG. Physicochemical properties of the molded samples were analyzed using DSC measurements and uniaxial tensile tests. The molding process resulted in a weakening of the PLLA tubular specimens with a simultaneous increase in the degree of crystallinity (χ.

  9. Post-deformation examination of specimens subjected to SCC testing

    Energy Technology Data Exchange (ETDEWEB)

    Gussev, Maxim N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Field, Kevin G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Busby, Jeremy T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Leonard, Keith J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-09-01

    This report details the results of post-radiation and post-deformation characterizations performed during FY 2015–FY 2016 on a subset of specimens that had previously been irradiated at high displacement per atom (dpa) damage doses. The specimens, made of commercial austenitic stainless steels and alloys, were subjected to stress-corrosion cracking tests (constant extension rate testing and crack growth testing) at the University of Michigan under conditions typical of nuclear power plants. After testing, the specimens were returned to Oak Ridge National Laboratory (ORNL) for further analysis and evaluation.

  10. An electronic specimen collection protocol schema (eSCPS). Document architecture for specimen management and the exchange of specimen collection protocols between biobanking information systems.

    Science.gov (United States)

    Eminaga, O; Semjonow, A; Oezguer, E; Herden, J; Akbarov, I; Tok, A; Engelmann, U; Wille, S

    2014-01-01

    The integrity of collection protocols in biobanking is essential for a high-quality sample preparation process. However, there is not currently a well-defined universal method for integrating collection protocols in the biobanking information system (BIMS). Therefore, an electronic schema of the collection protocol that is based on Extensible Markup Language (XML) is required to maintain the integrity and enable the exchange of collection protocols. The development and implementation of an electronic specimen collection protocol schema (eSCPS) was performed at two institutions (Muenster and Cologne) in three stages. First, we analyzed the infrastructure that was already established at both the biorepository and the hospital information systems of these institutions and determined the requirements for the sufficient preparation of specimens and documentation. Second, we designed an eSCPS according to these requirements. Finally, a prospective study was conducted to implement and evaluate the novel schema in the current BIMS. We designed an eSCPS that provides all of the relevant information about collection protocols. Ten electronic collection protocols were generated using the supplementary Protocol Editor tool, and these protocols were successfully implemented in the existing BIMS. Moreover, an electronic list of collection protocols for the current studies being performed at each institution was included, new collection protocols were added, and the existing protocols were redesigned to be modifiable. The documentation time was significantly reduced after implementing the eSCPS (5 ± 2 min vs. 7 ± 3 min; p = 0.0002). The eSCPS improves the integrity and facilitates the exchange of specimen collection protocols in the existing open-source BIMS.

  11. Defect Depth Measurement of Straight Pipe Specimen Using Shearography

    International Nuclear Information System (INIS)

    Chang, Ho Seob; Kim, Kyung Suk

    2012-01-01

    In the nuclear industry, wall thinning defect of straight pipe occur the enormous loss in life evaluation and safety evaluation. To use non-destructive technique, we measure deformation, vibration, defect evaluation. But, this techniques are a weak that is the measurement of the wide area is difficult and the time is caught long. In the secondary side of nuclear power plants mostly used steel pipe, artificiality wall thinning defect make in the side and different thickness make to the each other, wall thinning defect part of deformation measure by using shearography. In addition, optical measurement through deformation, vibration, defect evaluation evaluate pipe and thickness defects of pressure vessel is to evaluate quantitatively. By shearography interferometry to measure the pipe's internal wall thinning defect and the variation of pressure use the proposed technique, the quantitative defect is to evaluate the thickness of the surplus. The amount of deformation use thickness of surplus prediction of the actual thickness defect and approximately 7 percent error by ensure reliability. According to pressure the amount of deformation and the thickness of the surplus through DB construction, nuclear power plant pipe use wall thinning part soundness evaluation. In this study, pressure vessel of thickness defect measure proposed nuclear pipe of wall thinning defect prediction and integrity assessment technology development. As a basic research defected theory and experiment, pressure vessel of advanced stability and soundness and maintainability is expected to contribute foundation establishment

  12. Catalog of insect type specimens preserved at the Kunming Institute of Zoology, Chinese Academy of Science with corrections of some specimens.

    Science.gov (United States)

    Li, Kai-Qin; Wang, Yun-Zhen; Dong, Da-Zhi; Zhang, Li-Kun

    2015-09-18

    This article presents a list of insect types preserved in Kunming Natural History Museum of Zoology (KNHMZ). As of March, 2015, 3 412 type specimens belonging to 266 species/subspecies of 37 families in 9 orders (Odonata, Isoptera, Mantodea, Orthoptera, Hemiptera, Coleoptera, Diptera, Hymenoptera and Lepidoptera) are included. Information corrections of some specimens are provided in this article.

  13. Location specific in situ TEM straining specimens made using FIB

    International Nuclear Information System (INIS)

    Field, R.D.; Papin, P.A.

    2004-01-01

    A method has been devised and demonstrated for producing in situ straining specimens for the transmission electron microscope (TEM) from specific locations in a sample using a dual-beam focused ion beam (FIB) instrument. The specimen is removed from a polished surface in the FIB using normal methods and then attached to a pre-fabricated substrate in the form of a modified TEM tensile specimen. In this manner, specific features of the microstructure of a polished optical mount can be selected for in situ tensile straining. With the use of electron backscattered diffraction (EBSD), this technique could be extended to select specific orientations of the specimen as well

  14. Uniaxial compression tests on diesel contaminated frozen silty soil specimens

    International Nuclear Information System (INIS)

    Chenaf, D.; Stampli, N.; Bathurst, R.; Chapuis, R.P.

    1999-01-01

    Results of a uniaxial, unconfined compression test on artificial diesel-contaminated and uncontaminated frozen silty soils are discussed. The testing program involved 59 specimens. The results show that for the same fluid content, diesel contamination reduced the strength of the frozen specimens by increasing the unfrozen water content. For example, in specimens containing 50 per cent diesel oil of the fluid content by weight the maximum strength was reduced by 95 per cent compared to the strength of an uncontaminated specimen. Diesel contamination was also shown to contribute to the slippage between soil particles by acting as a lubricant, thus accelerating the loss of compressive strength.13 refs., 18 figs

  15. Evaluation of Sensor Configurations for Robotic Surgical Instruments.

    Science.gov (United States)

    Gómez-de-Gabriel, Jesús M; Harwin, William

    2015-10-27

    Designing surgical instruments for robotic-assisted minimally-invasive surgery (RAMIS) is challenging due to constraints on the number and type of sensors imposed by considerations such as space or the need for sterilization. A new method for evaluating the usability of virtual teleoperated surgical instruments based on virtual sensors is presented. This method uses virtual prototyping of the surgical instrument with a dual physical interaction, which allows testing of different sensor configurations in a real environment. Moreover, the proposed approach has been applied to the evaluation of prototypes of a two-finger grasper for lump detection by remote pinching. In this example, the usability of a set of five different sensor configurations, with a different number of force sensors, is evaluated in terms of quantitative and qualitative measures in clinical experiments with 23 volunteers. As a result, the smallest number of force sensors needed in the surgical instrument that ensures the usability of the device can be determined. The details of the experimental setup are also included.

  16. Distribution of isodose curves in urological surgical procedures

    International Nuclear Information System (INIS)

    Lanfredi, M.P.; Dias, J.H.; Ravazio, R.C.; Anés, M.; Bacelar, A.; Lykawka, R.

    2017-01-01

    During urological surgical procedures with fluoroscopy, the doses of the care team may be significant. However, the knowledge of the occupational exposure of these professionals is still very incipient in the national surgical centers. The objective of the study is to determine the isodose curves of the urological surgical procedures, in order to estimate the exposure of the personnel involved. The equipment used was a Arco-C BV Philips Bracelet. Patients with thicknesses of 20 and 28 cm were simulated using acrylic plates. The dose rates were measured with RaySafe i2 Unfors dosimeters positioned in a 50 x 50 cm mesh at three different heights of the floor: 95, 125 and 165 centimeters respectively corresponding to the gonadal, thoracic and crystalline regions of a typical adult . The isodose curves applied to the distribution of the surgical team suggest that the exposures are in the following descending order of intensity: primary physician, auxiliary physician, scrub nurse, anesthetist and nurse

  17. Additive Manufacturing for Surgical Planning of Mandibular Fracture

    Directory of Open Access Journals (Sweden)

    Nadja Maria da Silva Oliveira Brito

    2016-01-01

    Full Text Available Currently, imaging techniques such as Computed Tomography with three-dimensional reconstruction (3D and Magnetic Resonances are being routinely used in pre-surgical planning in all fields of medicine. Nowadays, virtual three-dimensional images, commonly displayed on two-dimensional surfaces, such as the computer screen, can be used to produce rapidly prototyped models, with excellent dimensional accuracy and fine reproduction of anatomical structures, providing professionals with the ability to use the biomodel in planning and simulating medical and dental procedures (oral and maxillofacial surgery, making individualized facial implants and prostheses, measurements and previous adaptations of prefabricated fixation plates, thus contributing to considerable reductions in surgical time and consequently the duration of anesthesia, minimizing infection risks and reducing hospital costs. In this report, we describe a case of surgical planning and treatment of bilateral atrophic mandibular fracture, in which, for surgical planning, authors used Rapid Prototyping as an adjunct tool, considering the advantages already outlined.

  18. Effects of Specimen Diameters on the Distribution of Corrosion Fatigue Cracks

    OpenAIRE

    石原, 外美; 塩澤, 和章; 宮尾, 嘉寿

    1988-01-01

    The distribution of corrosion fatigue cracks observed on the un-notched round specimen surface differs with specimen diameter, especially in the low stress amplitude region. At a constant fatigue life ratio, many long cracks are initiated on the larger specimen, 12 mm (diameter), in comparison with the smaller specimen, 6 mm (diameter). On the other hand, in the high stress amplitude region of corrosion fatigue and fatigue in laboratory air, the distribution of cracks during the fatigue proce...

  19. Post-Flight Analysis of Selected Fluorocarbon and Other Thin Film Polymer Specimens Flown on MISSE-5

    Science.gov (United States)

    DeGroh, Kim; Finckenor, Miria; Minton, Tim; Brunsvold, Amy; Pippin, Gary

    2007-01-01

    Twenty thin film specimens were flown on M1SSE-5 as a cooperative effort between several organizations. This presentation will report results of initial inspections and post-flight measurements of the optical properties and recession of these materials due to the approx.13 month exposure period on the exterior of the International Space Station. These specimens were located on the "anti-solar" side of the MISSE-5 container and received a low number of Equivalent Sun Hours of solar UV exposure. Profilometry and/or ATF measurements will be conducted to determine thickness changes and atomic oxygen-induced recession rates Six of the specimens were covered with thin Kapton films, 0.1 and 0.3 mil in thickness. The 0.1 mil Kapton was almost completely eroded, suggesting that the atomic oxygen fluence is <8 x 10(exp 19) atoms/sq cm, similar to levels experienced during Space Shuttle materials experiments in the 1980's and 1990's. A comparison of results from MISSE-5 and Space Shuttle experiments will be included for those materials common to both the short and long-term exposures.

  20. Detecting Rickettsia parkeri Infection from Eschar Swab Specimens

    Science.gov (United States)

    2013-05-01

    Detecting Rickettsia parkeri Infection from Eschar Swab Specimens Todd Myers, Tahaniyat Lalani, Mike Dent, Ju Jiang, Patrick L. Daly, Jason D...Maguire, and Allen L. Richards The typical clinical presentation of several spotted fever group Rickettsia infections includes eschars. Clinical...diagnosis by using an eschar swab specimen from patients infected with Rickettsia parkeri. Until 2004, all confirmed cases of tick-borne spotted