WorldWideScience

Sample records for surgical assessment device

  1. Surgical tools and medical devices

    CERN Document Server

    Jackson, Mark

    2016-01-01

    This new edition presents information and knowledge on the field of biomedical devices and surgical tools. The authors look at the interactions between nanotechnology, nanomaterials, design, modeling, and tools for surgical and dental applications, as well as how nanostructured surfaces can be created for the purposes of improving cell adhesion between medical devices and the human body. Each original chapter is revised in this second edition and describes developments in coatings for heart valves, stents, hip and knee joints, cardiovascular devices, orthodontic applications, and regenerative materials such as bone substitutes. There are also 8 new chapters that address: Microvascular anastomoses Inhaler devices used for pulmonary delivery of medical aerosols Surface modification of interference screws Biomechanics of the mandible (a detailed case study) Safety and medical devices The synthesis of nanostructured material Delivery of anticancer molecules using carbon nanotubes Nano and micro coatings for medic...

  2. Surgical virtual reality - highlights in developing a high performance surgical haptic device.

    Science.gov (United States)

    Custură-Crăciun, D; Cochior, D; Constantinoiu, S; Neagu, C

    2013-01-01

    Just like simulators are a standard in aviation and aerospace sciences, we expect for surgical simulators to soon become a standard in medical applications. These will correctly instruct future doctors in surgical techniques without there being a need for hands on patient instruction. Using virtual reality by digitally transposing surgical procedures changes surgery in are volutionary manner by offering possibilities for implementing new, much more efficient, learning methods, by allowing the practice of new surgical techniques and by improving surgeon abilities and skills. Perfecting haptic devices has opened the door to a series of opportunities in the fields of research,industry, nuclear science and medicine. Concepts purely theoretical at first, such as telerobotics, telepresence or telerepresentation,have become a practical reality as calculus techniques, telecommunications and haptic devices evolved,virtual reality taking a new leap. In the field of surgery barrier sand controversies still remain, regarding implementation and generalization of surgical virtual simulators. These obstacles remain connected to the high costs of this yet fully sufficiently developed technology, especially in the domain of haptic devices. Celsius.

  3. Cross-platform digital assessment forms for evaluating surgical skills

    Directory of Open Access Journals (Sweden)

    Steven Arild Wuyts Andersen

    2015-04-01

    Full Text Available A variety of structured assessment tools for use in surgical training have been reported, but extant assessment tools often employ paper-based rating forms. Digital assessment forms for evaluating surgical skills could potentially offer advantages over paper-based forms, especially in complex assessment situations. In this paper, we report on the development of cross-platform digital assessment forms for use with multiple raters in order to facilitate the automatic processing of surgical skills assessments that include structured ratings. The FileMaker 13 platform was used to create a database containing the digital assessment forms, because this software has cross-platform functionality on both desktop computers and handheld devices. The database is hosted online, and the rating forms can therefore also be accessed through most modern web browsers. Cross-platform digital assessment forms were developed for the rating of surgical skills. The database platform used in this study was reasonably priced, intuitive for the user, and flexible. The forms have been provided online as free downloads that may serve as the basis for further development or as inspiration for future efforts. In conclusion, digital assessment forms can be used for the structured rating of surgical skills and have the potential to be especially useful in complex assessment situations with multiple raters, repeated assessments in various times and locations, and situations requiring substantial subsequent data processing or complex score calculations.

  4. The safe use of surgical energy devices by surgeons may be overestimated.

    Science.gov (United States)

    Ha, Ally; Richards, Carly; Criman, Erik; Piaggione, Jillian; Yheulon, Christopher; Lim, Robert

    2018-03-01

    Surgical energy injuries are an underappreciated phenomenon. Improper use of surgical energy or poor attention to patient safety can result in operating room fires, tissue injuries, and interferences with other electronic devices, while rare complications can be devastatingly severe. Despite this, there is no current standard requirement for educating surgeons on the safe use of energy-based devices or evaluation of electrosurgery (ES) education in residency training, credentialing, or practice. The study aimed to assess the current baseline knowledge of surgeons and surgical trainees with regards to ES across varying experiences at a tertiary level care center. Surgeons and surgical trainees from seven surgical specialties (General Surgery, Cardiothoracic Surgery, Vascular Surgery, Obstetrics/Gynecology, Orthopedic Surgery, Urology, and Otorhinolaryngology) at a tertiary level care hospital were tested. Testing included an evaluation regarding their background training and experiences with ES-related adverse events and a 15 multiple-choice-question exam testing critical knowledge of ES. A total of 134 surveys were sent out with 72 responses (53.7%). The mean quiz score was 51.5 ± 15.5% (passing score was 80%). Of staff surgeons, 33/65 (50.8%) completed the survey with mean and median scores of 54.9 and 53.3%, respectively (range 33.3-86.7%). Of surgical trainees, 39/69 (56.5%) completed the survey with mean and median scores of 48.6 and 46.7%, respectively (range 13.3-80.0%). There were no statistically significant differences based on training status (p = 0.08), previous training (p = 0.24), number of cases (p = 0.06), or specialty (p = 0.689). Surgeons and surgical trainees both have a significant knowledge gap in the safe and effective use of surgical energy devices, regardless of surgical specialty and despite what they feel was adequate training. The knowledge gap is not improved with experience. A formal surgical energy education program

  5. Interspinous process device versus standard conventional surgical decompression for lumbar spinal stenosis: Randomized controlled trial

    NARCIS (Netherlands)

    W.A. Moojen (Wouter); M.P. Arts (Mark); W.C.H. Jacobs (Wilco); E.W. van Zwet (Erik); M.E. van den Akker-van Marle (Elske); B.W. Koes (Bart); C.L.A.M. Vleggeert-Lankamp (Carmen); W.C. Peul (Wilco)

    2013-01-01

    markdownabstractAbstract Objective To assess whether interspinous process device implantation is more effective in the short term than conventional surgical decompression for patients with intermittent neurogenic claudication due to lumbar spinal stenosis. Design Randomized controlled

  6. Surgical treatment of complications associated with the Angio-Seal vascular closure device.

    Science.gov (United States)

    Cikirikcioglu, Mustafa; Cherian, Sanjay; Keil, Vera; Manzano, Norman; Gemayel, Gino; Theologou, Thomas; Kalangos, Afksendiyos

    2011-05-01

    Vascular closure devices are used to provide quick hemostasis and early ambulation after percutaneous interventions. The Angio-Seal (AS) vascular closure device forms a mechanical seal by closing the puncture site located between a bioabsorbable anchor within the lumen and a collagen sponge on the adventitia. Although morbidities associated with AS are reportedly infrequent, even the slightest inaccuracy in device implantation may result in displacement of these device components, leading to sudden and severe complications. We report the surgical treatment of complications associated with the use of AS in four patients, including acute limb ischemia, pseudoaneurysm formation, significant hemorrhage, and hypovolemic shock. A common factor in all these cases was that the components of the AS device were displaced from their original site of implantation, stressing the importance of proper device placement. All patients underwent successful surgical vascular repair. Our report highlights the need for exercising extreme care during device implantation, and also the requirement for vigilant inspection for any associated vascular complications commencing immediately after device implantation. It is vital that these device components are actively looked for and removed during surgical exploration so as to prevent future complications. Copyright © 2011. Published by Elsevier Inc.

  7. Vaginoscopy in Ewes Utilizing a Laparoscopic Surgical Port Device

    Directory of Open Access Journals (Sweden)

    Jeremiah Easley

    2017-01-01

    Full Text Available Vaginoscopy allows for diagnostic evaluation and treatment of the vaginal vault. A laparoscopic surgical port device and rigid telescope were utilized for serial vaginoscopy in 8 healthy anesthetized ewes. Vaginoscopy examinations were performed in each ewe at days 1, 14, and 28. This technique was well-tolerated and facilitated carbon dioxide vaginal inflation, complete vaginal examination, identification of the cervix, and targeted biopsy collection. No complications were encountered during or following the vaginoscopy procedures. The laparoscopic port device was well-suited to the ewe vulvar size. This technique could be applied to clinical evaluation in ewes for the purposes of examination, biopsy, culture, foreign body removal, and minor surgical procedures.

  8. Patient views on financial relationships between surgeons and surgical device manufacturers.

    Science.gov (United States)

    Camp, Mark W; Gross, Allan E; McKneally, Martin F

    2015-10-01

    Over the past decade, revelations of inappropriate financial relationships between surgeons and surgical device manufacturers have challenged the presumption that surgeons can collaborate with surgical device manufacturers without damaging public trust in the surgical profession. We explored postoperative Canadian patients' knowledge and opinions about financial relationships between surgeons and surgical device manufacturers. This complex issue was explored using qualitative methods. We conducted semistructured face-to-face interviews with postoperative patients in follow-up arthroplasty clinics at an academic hospital in Toronto, Canada. Interviews were audiotaped, transcribed and analyzed. Patient-derived concepts and themes were uncovered. We interviewed 33 patients. Five major themes emerged: 1) many patients are unaware of the existence of financial relationships between surgeons and surgical device manufacturers; 2) patients approve of financial relationships that support innovation and research but are opposed to relationships that involve financial incentives that benefit only the surgeon and the manufacturer; 3) patients do not support disclosure of financial relationships during the consent process as it may shift focus away from the more important risks; 4) patients support oversight at the professional level but reject the idea of government involvement in oversight; and 5) patients entrust their surgeons to make appropriate patient-centred choices. This qualitative study deepens our understanding of financial relationships between surgeons and industry. Patients support relationships with industry that provide potential benefit to current or future patients. They trust our ability to self-regulate. Disclosure combined with appropriate oversight will strengthen public trust in professional collaboration with industry.

  9. Urgent surgical management for embolized occluder devices in childhood: single center experience

    Directory of Open Access Journals (Sweden)

    Gokaslan Gokhan

    2012-12-01

    Full Text Available Abstract Background In this study, we sought to analyze our experience in urgent surgical management for embolized cardiac septal and ductal occluder devices resulting from trans-catheter closure of atrial septal defect, ventricular septal defect and patent ductus arteriosus in childhood patient group. Methods We retrospectively reviewed 9 patients (aged 2–15 years who underwent urgent surgery due to cardiac septal and ductal occluder embolization between January 2007 and December 2010. Congenital defects were atrial septal defect (n = 6, ventricular septal defect (n = 1, and patent ductus arteriosus (n = 2. Risk factors for device embolization and urgent surgical management techniques for embolized device removal were discussed. Results Removal of embolized devices in all cases and repair of damaged tricuspid valve in 2 patients were performed. Inevitably, all congenital defects were closed or ligated up to the primary defect. Total circulator arrest necessitated in 1 patient with ascending aortic device embolization. All operations were completed successfully and no hospital mortality or morbidity was encountered. Conclusions Although closure of left to right shunting defects by percutaneous occluder devices has a lot of advantages, device embolization is still a major complication. If embolized device retrieval fails with percutaneous intervention attempts, surgical management is the only method to remove embolized devices. In this circumstance, to provide an uneventful perioperative course, urgent management strategies should be well planned.

  10. 78 FR 11207 - Clinical Study Designs for Surgical Ablation Devices for Treatment of Atrial Fibrillation...

    Science.gov (United States)

    2013-02-15

    ...] Clinical Study Designs for Surgical Ablation Devices for Treatment of Atrial Fibrillation; Guidance for... devices intended for the treatment of atrial fibrillation. DATES: Submit either electronic or written... Study Designs for Surgical Ablation Devices for Treatment of Atrial Fibrillation'' to the Division of...

  11. Ethical issues associated with the introduction of new surgical devices, or just because we can, doesn't mean we should.

    Science.gov (United States)

    Ross, Sue; Robert, Magali; Harvey, Marie-Andrée; Farrell, Scott; Schulz, Jane; Wilkie, David; Lovatsis, Danny; Epp, Annette; Easton, Bill; McMillan, Barry; Schachter, Joyce; Gupta, Chander; Weijer, Charles

    2008-06-01

    Surgical devices are often marketed before there is good evidence of their safety and effectiveness. Our paper discusses the ethical issues associated with the early marketing and use of new surgical devices from the perspectives of the six groups most concerned. Health Canada, which is responsible for licensing new surgical devices, should amend their requirements to include rigorous clinical trials that provide data on effectiveness and safety for each new product before it is marketed. Industry should comply with all Health Canada requirements to obtain licenses for new products. Until Health Canada requires effectiveness and safety data, industry should cooperate with physicians in appropriate studies before releasing new products and should make balanced presentations of all the available evidence. Surgeons should, before using a new surgical device, assess the evidence on its effectiveness and safety and ensure they are properly trained and competent in using the device. Surgeons should provide their patients with an evaluation of the available evidence and inform them about possible complications and the surgeon's level of experience with the new device. Patients, who should be given an honest evaluation of the available evidence, possible complications, and the surgeon's experience, should be encouraged to evaluate the evidence and information to their own satisfaction to ensure that fully informed consent is given. Health institutions, responsible for regulating practice within their walls, should review new devices for safety, effectiveness, and economic impacts, before allowing their use. They should also limit the use of new surgical devices to surgeons trained and competent in the new technology. Professional societies should provide guidance on the early adoption of new surgical devices and technologies. We urge all those involved in the development, licensing, and use of new surgical devices to aim for higher ethical standards to protect the health

  12. Evolution of general surgical problems in patients with left ventricular assist devices.

    Science.gov (United States)

    McKellar, Stephen H; Morris, David S; Mauermann, William J; Park, Soon J; Zietlow, Scott P

    2012-11-01

    Left ventricular assist devices (LVADs) are increasingly used to treat patients with end-stage heart failure. These patients may develop acute noncardiac surgical problems around the time of LVAD implantation or, as survival continues to improve, chronic surgical problems as ambulatory patients remote from the LVAD implant. Previous reports of noncardiac surgical problems in LVAD patients included patients with older, first-generation devices and do not address newer, second-generation devices. We describe the frequency and management of noncardiac surgical problems encountered during LVAD support with these newer-generation devices to assist noncardiac surgeons involved in the care of patients with LVADs. We retrospectively reviewed the medical records of consecutive patients receiving LVADs at our institution. We collected data for any consultation by noncardiac surgeons within the scope of general surgery during LVAD support and subsequent treatment. Ninety-nine patients received implantable LVADs between 2003 and 2009 (first-generation, n = 19; second-generation, n = 80). Excluding intestinal hemorrhage, general surgical opinions were rendered for 34 patients with 49 problems, mostly in the acute recovery phase after LVAD implantation. Of those, 27 patients underwent 28 operations. Respiratory failure and intra-abdominal pathologies were the most common problems addressed, and LVAD rarely precluded operation. Patients with second-generation LVADs were more likely to survive hospitalization (P = .04) and develop chronic, rather than emergent, surgical problems. Patients with LVADs frequently require consultation from noncardiac surgeons within the scope of general surgeons and often require operation. Patients with second-generation LVADs are more likely to become outpatients and develop more elective surgical problems. Noncardiac surgeons will be increasingly involved in caring for patients with LVADs and should anticipate the problems unique to this patient

  13. WE-G-204-08: Optimized Digital Radiographic Technique for Lost Surgical Devices/Needle Identification

    International Nuclear Information System (INIS)

    Gorman, A; Seabrook, G; Brakken, A; Dubois, M; Marn, C; Wilson, C; Jacobson, D; Liu, Y

    2015-01-01

    Purpose: Small surgical devices and needles are used in many surgical procedures. Conventionally, an x-ray film is taken to identify missing devices/needles if post procedure count is incorrect. There is no data to indicate smallest surgical devices/needles that can be identified with digital radiography (DR), and its optimized acquisition technique. Methods: In this study, the DR equipment used is a Canon RadPro mobile with CXDI-70c wireless DR plate, and the same DR plate on a fixed Siemens Multix unit. Small surgical devices and needles tested include Rubber Shod, Bulldog, Fogarty Hydrogrip, and needles with sizes 3-0 C-T1 through 8-0 BV175-6. They are imaged with PMMA block phantoms with thickness of 2–8 inch, and an abdomen phantom. Various DR techniques are used. Images are reviewed on the portable x-ray acquisition display, a clinical workstation, and a diagnostic workstation. Results: all small surgical devices and needles are visible in portable DR images with 2–8 inch of PMMA. However, when they are imaged with the abdomen phantom plus 2 inch of PMMA, needles smaller than 9.3 mm length can not be visualized at the optimized technique of 81 kV and 16 mAs. There is no significant difference in visualization with various techniques, or between mobile and fixed radiography unit. However, there is noticeable difference in visualizing the smallest needle on a diagnostic reading workstation compared to the acquisition display on a portable x-ray unit. Conclusion: DR images should be reviewed on a diagnostic reading workstation. Using optimized DR techniques, the smallest needle that can be identified on all phantom studies is 9.3 mm. Sample DR images of various small surgical devices/needles available on diagnostic workstation for comparison may improve their identification. Further in vivo study is needed to confirm the optimized digital radiography technique for identification of lost small surgical devices and needles

  14. Tissue quality assessment using a novel direct elasticity assessment device (the E-finger): a cadaveric study of prostatectomy dissection.

    Science.gov (United States)

    Good, Daniel W; Khan, Ashfaq; Hammer, Steven; Scanlan, Paul; Shu, Wenmiao; Phipps, Simon; Parson, Simon H; Stewart, Grant D; Reuben, Robert; McNeill, S Alan

    2014-01-01

    Minimally invasive radical prostatectomy (RP) (robotic and laparoscopic), have brought improvements in the outcomes of RP due to improved views and increased degrees of freedom of surgical devices. Robotic and laparoscopic surgeries do not incorporate haptic feedback, which may result in complications secondary to inadequate tissue dissection (causing positive surgical margins, rhabdosphincter damage, etc). We developed a micro-engineered device (6 mm2 sized) [E-finger]) capable of quantitative elasticity assessment, with amplitude ratio, mean ratio and phase lag representing this. The aim was to assess the utility of the device in differentiating peri-prostatic tissue types in order to guide prostate dissection. Two embalmed and 2 fresh frozen cadavers were used in the study. Baseline elasticity values were assessed in bladder, prostate and rhabdosphincter of pre-dissected embalmed cadavers using the micro-engineered device. A measurement grid was created to span from the bladder, across the prostate and onto the rhabdosphincter of fresh frozen cadavers to enable a systematic quantitative elasticity assessment of the entire area by 2 independent assessors. Tissue was sectioned along each row of elasticity measurement points, and stained with haematoxylin and eosin (H&E). Image analysis was performed with Image Pro Premier to determine the histology at each measurement point. Statistically significant differences in elasticity were identified between bladder, prostate and sphincter in both embalmed and fresh frozen cadavers (p = elasticity assessment device to differentiate bladder, prostate and rhabdosphincter to a resolution of 6 mm2. The results provide useful data for which to continue to examine the use of elasticity assessment devices for tissue quality assessment with the aim of giving haptic feedback to surgeons performing complex surgery.

  15. Approaching time is important for assessment of endoscopic surgical skills.

    Science.gov (United States)

    Tokunaga, Masakazu; Egi, Hiroyuki; Hattori, Minoru; Yoshimitsu, Masanori; Sumitani, Daisuke; Kawahara, Tomohiro; Okajima, Masazumi; Ohdan, Hideki

    2012-05-01

    This study aimed to verify whether the approaching time (the time taken to reach the target point from another point, a short distance apart, during point-to-point movement in endoscopic surgery), assessed using the Hiroshima University Endoscopic Surgical Assessment Device (HUESAD), could distinguish the skill level of surgeons. Expert surgeons (who had performed more than 50 endoscopic surgeries) and novice surgeons (who had no experience in performing endoscopic surgery) were tested using the HUESAD. The approaching time, total time, and intermediate time (total time--approaching time) were measured and analyzed using the trajectory of the tip of the instrument. The approaching time and total time were significantly shorter in the expert group than in the novice group (p time did not significantly differ between the groups (p > 0.05). The approaching time, which is a component of the total time, is very mportant in the measurement of the total time to assess endoscopic surgical skills. Further, the approaching time was useful for skill assessment by the HUESAD for evaluating the skill of surgeons performing endoscopic surgery.

  16. SIM Life: a new surgical simulation device using a human perfused cadaver.

    Science.gov (United States)

    Faure, J P; Breque, C; Danion, J; Delpech, P O; Oriot, D; Richer, J P

    2017-02-01

    In primary and continuing medical education, simulation is becoming a mandatory technique. In surgery, simulation spreading is slowed down by the distance which exists between the devices currently available on the market and the reality, in particular anatomical, of an operating room. We propose a new model for surgical simulation with the use of cadavers in a circulation model mimicking pulse and artificial respiration available for both open and laparoscopic surgery. The model was a task trainer designed by four experts in our simulation laboratory combining plastic, electronic, and biologic material. The cost of supplies needed for the construction was evaluated. The model was used and tested over 24 months on 35 participants, of whom 20 were surveyed regarding the realism of the model. The model involved a cadaver, connected to a specific device that permits beating circulation and artificial respiration. The demonstration contributed to teaching small groups of up to four participants and was reproducible over 24 months of courses. Anatomic correlation, realism, and learning experience were highly rated by users CONCLUSION: This model for surgical simulation in both open and laparoscopic surgery was found to be realistic, available to assessed objectively performance in a pedagogic program.

  17. Gastroenterology-Urology Devices; Manual Gastroenterology-Urology Surgical Instruments and Accessories. Final rule; technical amendment.

    Science.gov (United States)

    2017-03-01

    The Food and Drug Administration (FDA) is amending the identification of manual gastroenterology-urology surgical instruments and accessories to reflect that the device does not include specialized surgical instrumentation for use with urogyencologic surgical mesh specifically intended for use as an aid in the insertion, placement, fixation, or anchoring of surgical mesh during urogynecologic procedures ("specialized surgical instrumentation for use with urogynecologic surgical mesh"). These amendments are being made to reflect changes made in the recently issued final reclassification order for specialized surgical instrumentation for use with urogynecologic surgical mesh.

  18. Assessment of Surgical Skills and Competency.

    Science.gov (United States)

    Bhatti, Nasir I

    2017-10-01

    Evaluation of surgical skills and competency are important aspects of the medical education process. Measurable and reproducible methods of assessment with objective feedback are essential components of surgical training. Objective Structured Assessment of Technical Skills (OSATS) is widely used across the medical specialties and otolaryngology-specific tools have been developed and validated for sinus and mastoid surgery. Although assessment of surgical skills can be time-consuming and requires human and financial resources, new evaluation methods and emerging technology may alleviate these barriers while also improving data collection practices. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Improvement of design of a surgical interface using an eye tracking device.

    Science.gov (United States)

    Erol Barkana, Duygun; Açık, Alper; Duru, Dilek Goksel; Duru, Adil Deniz

    2014-05-07

    Surgical interfaces are used for helping surgeons in interpretation and quantification of the patient information, and for the presentation of an integrated workflow where all available data are combined to enable optimal treatments. Human factors research provides a systematic approach to design user interfaces with safety, accuracy, satisfaction and comfort. One of the human factors research called user-centered design approach is used to develop a surgical interface for kidney tumor cryoablation. An eye tracking device is used to obtain the best configuration of the developed surgical interface. Surgical interface for kidney tumor cryoablation has been developed considering the four phases of user-centered design approach, which are analysis, design, implementation and deployment. Possible configurations of the surgical interface, which comprise various combinations of menu-based command controls, visual display of multi-modal medical images, 2D and 3D models of the surgical environment, graphical or tabulated information, visual alerts, etc., has been developed. Experiments of a simulated cryoablation of a tumor task have been performed with surgeons to evaluate the proposed surgical interface. Fixation durations and number of fixations at informative regions of the surgical interface have been analyzed, and these data are used to modify the surgical interface. Eye movement data has shown that participants concentrated their attention on informative regions more when the number of displayed Computer Tomography (CT) images has been reduced. Additionally, the time required to complete the kidney tumor cryoablation task by the participants had been decreased with the reduced number of CT images. Furthermore, the fixation durations obtained after the revision of the surgical interface are very close to what is observed in visual search and natural scene perception studies suggesting more efficient and comfortable interaction with the surgical interface. The

  20. Comparison of effectiveness and cost of patent ductus arteriosus device occlusion versus surgical ligation of patent ductus arteriosus.

    Science.gov (United States)

    Zulqarnain, Arif; Younas, Muhammad; Waqar, Tariq; Beg, Ahsan; Asma, Touseef; Baig, Mirza Ahmad Raza

    2016-01-01

    Comparison of effectiveness and cost of transcatheter occlusion of patent ductus arteriosus (PDA) with surgical ligation of PDA. This retrospective comparative study was conducted in the pediatric cardiology department of Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Data of 250 patients who underwent patent ductus arteriosus (PDA) closure either surgical or trans-catheter closure using SHSMA Occluder having weight >5 kg from April 2012 to October 2015 were included in this study. SPSS version 20 was used for data analysis. Quantitative variables were compared using independent sample t-test. Chi-square test and fishers exact was used for qualitative variables. P-value <0.05 was considered statistically significant. There were one hundred and twenty (120) patients who underwent transcatheter occlusion of PDA using SHSMA occluder (PDA Device Group) and one hundred and thirty (130) patients who underwent surgical ligation of PDA (Surgical Group). Incidence of residual shunting was two (1.5%) in surgical group and 0 (0.0%) in PDA Device group for one month follow up period. There were 4 (3.1%) major complications in surgical group. The rate of blood transfusions were high in surgical group (p-value 0.04). Hospital stay time was significantly less in PDA Device group (P-value <0.001). Total procedural cost was 110695+1054 Pakistani rupees in PDA Device group and 92414+3512 in surgical group (p-value <0.001). The cost of PDA device closure was 16.52% higher than the surgical ligation of PDA. There was no operative mortality. The transcatheter closure of PDA is an effective and less invasive method as compared to the surgical ligation. There is a lower rate of complications and the cost is not much high as compared to surgical PDA ligation.

  1. Tissue quality assessment using a novel direct elasticity assessment device (the E-finger: a cadaveric study of prostatectomy dissection.

    Directory of Open Access Journals (Sweden)

    Daniel W Good

    Full Text Available Minimally invasive radical prostatectomy (RP (robotic and laparoscopic, have brought improvements in the outcomes of RP due to improved views and increased degrees of freedom of surgical devices. Robotic and laparoscopic surgeries do not incorporate haptic feedback, which may result in complications secondary to inadequate tissue dissection (causing positive surgical margins, rhabdosphincter damage, etc. We developed a micro-engineered device (6 mm2 sized [E-finger] capable of quantitative elasticity assessment, with amplitude ratio, mean ratio and phase lag representing this. The aim was to assess the utility of the device in differentiating peri-prostatic tissue types in order to guide prostate dissection.Two embalmed and 2 fresh frozen cadavers were used in the study. Baseline elasticity values were assessed in bladder, prostate and rhabdosphincter of pre-dissected embalmed cadavers using the micro-engineered device. A measurement grid was created to span from the bladder, across the prostate and onto the rhabdosphincter of fresh frozen cadavers to enable a systematic quantitative elasticity assessment of the entire area by 2 independent assessors. Tissue was sectioned along each row of elasticity measurement points, and stained with haematoxylin and eosin (H&E. Image analysis was performed with Image Pro Premier to determine the histology at each measurement point.Statistically significant differences in elasticity were identified between bladder, prostate and sphincter in both embalmed and fresh frozen cadavers (p = < 0.001. Intra-class correlation (ICC reliability tests showed good reliability (average ICC = 0.851. Sensitivity and specificity for tissue identification was 77% and 70% respectively to a resolution of 6 mm2.This cadaveric study has evaluated the ability of our elasticity assessment device to differentiate bladder, prostate and rhabdosphincter to a resolution of 6 mm2. The results provide useful data for which to continue to

  2. Economic and organizational sustainability of a negative-pressure portable device for the prevention of surgical-site complications

    Directory of Open Access Journals (Sweden)

    Foglia E

    2017-06-01

    Full Text Available Emanuela Foglia,1 Lucrezia Ferrario,1 Elisabetta Garagiola,1 Giuseppe Signoriello,2 Gianluca Pellino,3 Davide Croce,1,4 Silvestro Canonico3 1Centre for Health Economics, Social and Health Care Management - LIUC University, Castellanza, Italy; 2Department of Mental Health and Preventive Medicine, University of Campania “Luigi Vanvitelli”, Naples, Italy; 3School of Medicine, University of Campania “Luigi Vanvitelli”, Naples, Italy; 4School of Public Health, Faculty of Health Sciences, University of the Witwatersrand, Johannesburg, South \tAfrica Purpose: Surgical-site complications (SSCs affect patients’ clinical pathway, prolonging their hospitalization and incrementing their management costs. The present study aimed to assess the economic and organizational implications of a portable device for negative-pressure wound therapy (NPWT implementation, compared with the administration of pharmacological therapies alone for preventing surgical complications in patients undergoing general, cardiac, obstetrical–gynecological, or orthopedic surgical procedures.Patients and methods: A total of 8,566 hospital procedures, related to the year 2015 from one hospital, were evaluated considering infection risk index, occurrence rates of SSCs, drug therapies, and surgical, diagnostic, and specialist procedures and hematological exams. Activity-based costing and budget impact analyses were implemented for the economic assessment.Results: Patients developing an SSC absorbed i 64.27% more economic resources considering the length of stay (€ 8,269±2,096 versus € 5,034±2,901, p<0.05 and ii 42.43% more economic resources related to hematological and diagnostic procedures (€ 639±117 versus € 449±72, p<0.05. If the innovative device had been used over the 12-month time period, it would have decreased the risk of developing SSCs; the hospital would have realized an average reduction in health care expenditure equal to −0.69% (−€ 483

  3. Obstetrical and Gynecological Devices; Reclassification of Surgical Mesh for Transvaginal Pelvic Organ Prolapse Repair; Final order.

    Science.gov (United States)

    2016-01-05

    The Food and Drug Administration (FDA or the Agency) is issuing a final order to reclassify surgical mesh for transvaginal pelvic organ prolapse (POP) repair from class II to class III. FDA is reclassifying these devices based on the determination that general controls and special controls together are not sufficient to provide reasonable assurance of safety and effectiveness for this device, and these devices present a potential unreasonable risk of illness or injury. The Agency is reclassifying surgical mesh for transvaginal POP repair on its own initiative based on new information.

  4. Metrics for Objective Assessment of Surgical Skills Workshop

    National Research Council Canada - National Science Library

    Satava, Richard

    2001-01-01

    On 9-10 July, 2001 the Metrics for Objective Assessment of Surgical Skills Workshop convened an international assemblage of subject matter experts in objective assessment of surgical technical skills...

  5. Comparison of three cuffed emergency percutaneous cricothyroidotomy devices to conventional surgical cricothyroidotomy in a porcine model.

    LENUS (Irish Health Repository)

    Murphy, C

    2011-01-01

    Emergency cricothyroidotomy is a potentially life-saving procedure in the \\'cannot intubate cannot ventilate (CICV)\\' scenario. Although surgical cricothyroidotomy remains the technique recommended in many \\'CICV\\' algorithms, the insertion of a tracheostomy as a cannula over a trocar, or using the Seldinger method, may have advantages as they are more familiar to the anaesthetist. We compared the utility of three cuffed cricothyroidotomy devices: cuffed Melker®, Quicktrach 2®, and PCK® devices, with surgical cricothyroidotomy.

  6. Surgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients

    Directory of Open Access Journals (Sweden)

    Salim S

    2012-06-01

    Full Text Available Sarwat Salim, Haiming Du, Sumalee Boonyaleephan, Jim WanUniversity of Tennessee Health Science Center, Memphis, TN, USAPurpose: To compare the surgical outcomes of the Ex-PRESS glaucoma filtration device in African American and white glaucoma patients.Design: Retrospective comparative case series.Methods: This was a comparative case series of 36 eyes of 36 African Americans and 43 eyes of 43 whites that underwent placement of the Ex-PRESS glaucoma filtration device under a partial-thickness scleral flap for uncontrolled glaucoma. All eyes received intraoperative mitomycin C. The primary outcome measures were intraocular pressure (IOP, number of postoperative glaucoma medications, and surgical success. Surgical success was defined as IOP between 5 and 18 mm Hg, with or without glaucoma medications, without further glaucoma surgery, or loss of light perception vision. Results: Average follow-up was 31.9 ± 9.8 (range, 14.6–47 months for African Americans and 30.7 ± 8.6 (range, 14.3–47 months for whites. At 33 months, surgical success was 80.0% in the African American group and 83.3% in the white group (P = 1.00. Reasons for surgical failure included increased IOP (3 eyes, 3.8%, persistent hypotony with maculopathy (1 eye, 1.3%, and further surgery (4 eyes, 5.06%. Compared with preoperative values, the mean postoperative IOP and number of glaucoma medications were significantly reduced in both groups, and no statistical difference was observed between the two groups at 33 months. Postoperative complications were similar in the two groups.Conclusions: Similar surgical outcomes were observed in African American and white glaucoma patients after implantation of the Ex-PRESS glaucoma filtration device. This latest modification of glaucoma filtration surgery may be a better surgical option for African Americans given its potential advantages of no tissue removal, predictable outcomes related to consistent lumen size and controlled flow, fewer

  7. Cross-platform digital assessment forms for evaluating surgical skills

    DEFF Research Database (Denmark)

    Andersen, Steven Arild Wuyts

    2015-01-01

    developed for the rating of surgical skills. The database platform used in this study was reasonably priced, intuitive for the user, and flexible. The forms have been provided online as free downloads that may serve as the basis for further development or as inspiration for future efforts. In conclusion......A variety of structured assessment tools for use in surgical training have been reported, but extant assessment tools often employ paper-based rating forms. Digital assessment forms for evaluating surgical skills could potentially offer advantages over paper-based forms, especially in complex...... assessment situations. In this paper, we report on the development of cross-platform digital assessment forms for use with multiple raters in order to facilitate the automatic processing of surgical skills assessments that include structured ratings. The FileMaker 13 platform was used to create a database...

  8. Reversible hydronephrosis in the rat: a new surgical technique assessed by radioisotopic measurements

    International Nuclear Information System (INIS)

    Flam, T.; Venot, A.; Bariety, J.

    1984-01-01

    A new technique for experimental reversible hydronephrosis in the rat was developed. A noninvasive radioisotopic investigation, using Tc-99m dimercaptosuccinic acid, permitted sequential assessment of the separate renal function at different stages of the study. After 1 week of unilateral ureteral obstruction, reversibility was obtained by the removal of the obstructive device. Ten days after the obstruction release, the ipsilateral kidney had returned to 71 per cent of its preligation uptake value. Histological findings demonstrated the reversibility of the surgical obstruction

  9. Suture fixation of migrated septal occluder device to prevent further migration: a simple surgical technique

    Directory of Open Access Journals (Sweden)

    Mohite Prashant N

    2013-01-01

    Full Text Available Abstract As the use of percutaneous intervention is increasing for the closure of the atrial septal defect, the procedure related complications are also on rise, migration of the device being most common. The migrated devices with failed percutaneous retrieval must be removed surgically under cardiopulmonary bypass. During establishment of cardiopulmonary bypass, the handling of heart may cause further migration of the device into other chambers of heart which leads to difficulty in finding and retrieval of the device. The authors propose a simple and unique technique to prevent further migration of the septal occluder device.

  10. Assessment of technical and nontechnical skills in surgical residents.

    Science.gov (United States)

    Ponton-Carss, Alicia; Kortbeek, John B; Ma, Irene W Y

    2016-11-01

    Surgical competence encompasses both technical and nontechnical skills. This study seeks to evaluate the validity evidence for a comprehensive surgical skills examination and to examine the relationship between technical and nontechnical skills. Six examination stations assessing both technical and nontechnical skills, conducted yearly for surgical trainees (n = 120) between 2010 and 2014 are included. The assessment tools demonstrated acceptable internal consistency. Interstation reliability for technical skills was low (alpha = .39). Interstation reliability for the nontechnical skills was lower (alpha range -.05 to .31). Nontechnical skills domains were strongly correlated, ranging from r = .65, P skills were inconsistent, ranging from poor (r = -.06; P = .54) to moderate (r = .45; P skills are necessary to assess overall surgical competency. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. The Role of Crowdsourcing in Assessing Surgical Skills.

    Science.gov (United States)

    Katz, Andrew J

    2016-08-01

    Assessing surgical skill is critical in improving patient care while reducing medical errors, length of stay, and readmission rates. Crowdsourcing provides 1 potential method for accurately assessing this; only recently has crowdsourcing been studied as a valid way to provide feedback to surgeons. The results of such studies are explored. A systematic literature search was performed on PubMed to identify studies that have attempted to validate crowdsourcing as a method for assessing surgical skill. Through a combination of abstract screening and full-length review, 9 studies that met the inclusion criteria were reviewed. Crowdsourcing has been validated as an important way to provide feedback for surgical skill. It has been demonstrated to be effective in both dry-lab and live surgery, for a variety of tasks and methods. However, more studies must be performed to ensure that crowdsourcing can provide quality feedback in a wider variety of scenarios.

  12. Video and accelerometer-based motion analysis for automated surgical skills assessment.

    Science.gov (United States)

    Zia, Aneeq; Sharma, Yachna; Bettadapura, Vinay; Sarin, Eric L; Essa, Irfan

    2018-03-01

    Basic surgical skills of suturing and knot tying are an essential part of medical training. Having an automated system for surgical skills assessment could help save experts time and improve training efficiency. There have been some recent attempts at automated surgical skills assessment using either video analysis or acceleration data. In this paper, we present a novel approach for automated assessment of OSATS-like surgical skills and provide an analysis of different features on multi-modal data (video and accelerometer data). We conduct a large study for basic surgical skill assessment on a dataset that contained video and accelerometer data for suturing and knot-tying tasks. We introduce "entropy-based" features-approximate entropy and cross-approximate entropy, which quantify the amount of predictability and regularity of fluctuations in time series data. The proposed features are compared to existing methods of Sequential Motion Texture, Discrete Cosine Transform and Discrete Fourier Transform, for surgical skills assessment. We report average performance of different features across all applicable OSATS-like criteria for suturing and knot-tying tasks. Our analysis shows that the proposed entropy-based features outperform previous state-of-the-art methods using video data, achieving average classification accuracies of 95.1 and 92.2% for suturing and knot tying, respectively. For accelerometer data, our method performs better for suturing achieving 86.8% average accuracy. We also show that fusion of video and acceleration features can improve overall performance for skill assessment. Automated surgical skills assessment can be achieved with high accuracy using the proposed entropy features. Such a system can significantly improve the efficiency of surgical training in medical schools and teaching hospitals.

  13. Assessment methods in surgical training in the United Kingdom

    Directory of Open Access Journals (Sweden)

    Evgenios Evgeniou

    2013-02-01

    Full Text Available A career in surgery in the United Kingdom demands a commitment to a long journey of assessment. The assessment methods used must ensure that the appropriate candidates are selected into a programme of study or a job and must guarantee public safety by regulating the progression of surgical trainees and the certification of trained surgeons. This review attempts to analyse the psychometric properties of various assessment methods used in the selection of candidates to medical school, job selection, progression in training, and certification. Validity is an indicator of how well an assessment measures what it is designed to measure. Reliability informs us whether a test is consistent in its outcome by measuring the reproducibility and discriminating ability of the test. In the long journey of assessment in surgical training, the same assessment formats are frequently being used for selection into a programme of study, job selection, progression, and certification. Although similar assessment methods are being used for different purposes in surgical training, the psychometric properties of these assessment methods have not been examined separately for each purpose. Because of the significance of these assessments for trainees and patients, their reliability and validity should be examined thoroughly in every context where the assessment method is being used.

  14. Crowd-sourced assessment of surgical skills in cricothyrotomy procedure.

    Science.gov (United States)

    Aghdasi, Nava; Bly, Randall; White, Lee W; Hannaford, Blake; Moe, Kris; Lendvay, Thomas S

    2015-06-15

    Objective assessment of surgical skills is resource intensive and requires valuable time of expert surgeons. The goal of this study was to assess the ability of a large group of laypersons using a crowd-sourcing tool to grade a surgical procedure (cricothyrotomy) performed on a simulator. The grading included an assessment of the entire procedure by completing an objective assessment of technical skills survey. Two groups of graders were recruited as follows: (1) Amazon Mechanical Turk users and (2) three expert surgeons from University of Washington Department of Otolaryngology. Graders were presented with a video of participants performing the procedure on the simulator and were asked to grade the video using the objective assessment of technical skills questions. Mechanical Turk users were paid $0.50 for each completed survey. It took 10 h to obtain all responses from 30 Mechanical Turk users for 26 training participants (26 videos/tasks), whereas it took 60 d for three expert surgeons to complete the same 26 tasks. The assessment of surgical performance by a group (n = 30) of laypersons matched the assessment by a group (n = 3) of expert surgeons with a good level of agreement determined by Cronbach alpha coefficient = 0.83. We found crowd sourcing was an efficient, accurate, and inexpensive method for skills assessment with a good level of agreement to experts' grading. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Safety by design: effects of operating room floor marking on the position of surgical devices to promote clean air flow compliance and minimise infection risks

    NARCIS (Netherlands)

    de Korne, Dirk F.; van Wijngaarden, Jeroen D. H.; van Rooij, Jeroen; Wauben, Linda S. G. L.; Hiddema, U. Frans; Klazinga, Niek S.

    2012-01-01

    To evaluate the use of floor marking on the positioning of surgical devices within the clean air flow in an operating room (OR) to minimise infection risk. Laminar flow clean air systems are important in preventing infection in ORs but, for optimal results, surgical devices must be correctly

  16. [Intelligent operating room suite : From passive medical devices to the self-thinking cognitive surgical assistant].

    Science.gov (United States)

    Kenngott, H G; Wagner, M; Preukschas, A A; Müller-Stich, B P

    2016-12-01

    Modern operating room (OR) suites are mostly digitally connected but until now the primary focus was on the presentation, transfer and distribution of images. Device information and processes within the operating theaters are barely considered. Cognitive assistance systems have triggered a fundamental rethinking in the automotive industry as well as in logistics. In principle, tasks in the OR, some of which are highly repetitive, also have great potential to be supported by automated cognitive assistance via a self-thinking system. This includes the coordination of the entire workflow in the perioperative process in both the operating theater and the whole hospital. With corresponding data from hospital information systems, medical devices and appropriate models of the surgical process, intelligent systems could optimize the workflow in the operating theater in the near future and support the surgeon. Preliminary results on the use of device information and automatically controlled OR suites are already available. Such systems include, for example the guidance of laparoscopic camera systems. Nevertheless, cognitive assistance systems that make use of knowledge about patients, processes and other pieces of information to improve surgical treatment are not yet available in the clinical routine but are urgently needed in order to automatically assist the surgeon in situation-related activities and thus substantially improve patient care.

  17. The assessment of surgical skills as a complement to the training method. Revision.

    Science.gov (United States)

    Sánchez-Fernández, J; Bachiller-Burgos, J; Serrano-Pascual, Á; Cózar-Olmo, J M; Díaz-Güemes Martín-Portugués, I; Pérez-Duarte, F J; Hernández-Hurtado, L; Álvarez-Ossorio, J L; Sánchez-Margallo, F M

    2016-01-01

    The acquisition and improvement of surgical skills constitute a fundamental element in the training of any practitioner. At present, however, the assessment of these skills is a scarcely developed area of research. The aim of this study was to analyse the peculiarities of the various assessment systems and establish the minimum criteria that a skills and knowledge assessment system should meet as a method for assessing surgical skills in urological surgery. Scientific literature review aimed at the various currently available assessment systems for skills and competencies (technical and nontechnical), with a special focus on the systematic reviews and prospective studies. After conducting the review, we found that the various assessment systems for surgical competence have, in our opinion, a number of shortcomings. There is a certain degree of subjectivity in the assessment of surgeons by the evaluators. The assessment of nontechnical competencies is not formally recorded. There is no description of a follow-up assessment or any basic parameters associated with healthcare quality. There is no registration of associated competencies associated with the various surgical techniques. There is also no ranking of these competencies and the specific peculiarities for their application. We believe that the development of a new assessment system for surgical competencies (technical and nontechnical) aimed at assessing urologists in the various surgical techniques is necessary. To this end, our team has worked on developing the Evaluation System for Surgical Competencies on Laparoscopy, which is based on the definition, ranking and assessment of competencies demonstrated by surgeons. Copyright © 2015 AEU. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. [Surgical assessment of complications after thyroid gland operations].

    Science.gov (United States)

    Dralle, H

    2015-01-01

    The extent, magnitude and technical equipment used for thyroid surgery has changed considerably in Germany during the last decade. The number of thyroidectomies due to benign goiter have decreased while the extent of thyroidectomy, nowadays preferentially total thyroidectomy, has increased. Due to an increased awareness of surgical complications the number of malpractice claims is increasing. In contrast to surgical databases the frequency of complications in malpractice claims reflects the individual impact of complications on the quality of life. In contrast to surgical databases unilateral and bilateral vocal fold palsy are therefore at the forefront of malpractice claims. As guidelines are often not applicable for the individual surgical expert review, the question arises which are the relevant criteria for the professional expert witness assessing the severity of the individual complication. While in surgical databases major complications after thyroidectomy, such as vocal fold palsy, hypoparathyroidism, hemorrhage and infections are equally frequent (1-3 %), in malpractice claims vocal fold palsy is significantly more frequent (50 %) compared to hypoparathyroidism (15 %), hemorrhage and infections (about 5 % each). To avoid bilateral nerve palsy intraoperative nerve monitoring has become of utmost importance for surgical strategy and malpractice suits alike. For surgical expert review documentation of individual risk-oriented indications, the surgical approach and postoperative management are highly important. Guidelines only define the treatment corridors of good clinical practice. Surgical expert reviews in malpractice suits concerning quality of care and causality between surgical management, complications and sequelae of complications are therefore highly dependent on the grounds and documentation of risk-oriented indications for thyroidectomy, intraoperative and postoperative surgical management.

  19. A Randomized Trial of Pocket-Echocardiography Integrated Mobile Health Device Assessments in Modern Structural Heart Disease Clinics.

    Science.gov (United States)

    Bhavnani, Sanjeev P; Sola, Srikanth; Adams, David; Venkateshvaran, Ashwin; Dash, P K; Sengupta, Partho P

    2018-04-01

    This study sought to determine whether mobile health (mHealth) device assessments used as clinical decision support tools at the point-of-care can reduce the time to treatment and improve long-term outcomes among patients with rheumatic and structural heart diseases (SHD). Newly developed smartphone-connected mHealth devices represent promising methods to diagnose common diseases in resource-limited areas; however, the impact of technology-based care on long-term outcomes has not been rigorously evaluated. A total of 253 patients with SHD were randomized to an initial diagnostic assessment with wireless devices in mHealth clinics (n = 139) or to standard-care (n = 114) in India. mHealth clinics were equipped with point-of-care devices including pocket-echocardiography, smartphone-connected-electrocardiogram blood pressure and oxygen measurements, activity monitoring, and portable brain natriuretic peptide laboratory testing. All individuals underwent comprehensive transthoracic echocardiography to assess the severity of SHD. The primary endpoint was the time to referral for therapy with percutaneous valvuloplasty or surgical valve replacement. Secondary endpoints included the probability of a cardiovascular hospitalization and/or death over 1 year. An initial mHealth assessment was associated with a shorter time to referral for valvuloplasty and/or valve replacement (83 ± 79 days vs. 180 ± 101 days; p Mobile Health Device Assessments in Modern Structural Heart Disease Clinics; NCT02881398). Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. General surgical complications associated with the use of long-term mechanical circulatory support devices: are we 'under-reporting' problems?

    Science.gov (United States)

    Tchantchaleishvili, Vakhtang; Umakanthan, Ramanan; Karp, Seth; Stulak, John M; Keebler, Mary E; Maltais, Simon

    2013-05-01

    Multiple complications are associated with use of ventricular assist devices (VADs). Cardiac-related complications and infections are most frequently reported. VADs, however, can also lead to a number of general surgical complications equally significant in terms of morbidity and mortality. The authors performed a systematic literature search to review current data that specifically relate general surgical complications to patients who undergo left VAD implantation. The review provides a relatively clear understanding of the spectrum of general surgical complications and shows that they contribute significantly to morbidity and mortality in these patients.

  1. An effective method of surgical treatment of refractory glaucoma patients using Ex-PRESSTM filtering device

    Directory of Open Access Journals (Sweden)

    Sergey Yuryevich Astakhov

    2013-03-01

    Full Text Available Based on data obtained from examination and subsequent follow-up of 47 patients (50 eyes with refractory glaucoma, an efficacy estimation of a new method of the Ex-PRESSTM filtering device implantation was performed. The data analysis showed that the proposed surgical procedure has a low level of intra- and post-operative complications, is characterized by technical ease, and provides a long term stabilization of the glaucomatous process. Therefore it is possible to draw a conclusion that the Ex-PRESSTM filtering device implantation is an effective method for the treatment of refractory glaucoma.

  2. Use of a mobile device app: a potential new tool for poster presentations and surgical education.

    Science.gov (United States)

    Atherton, S; Javed, M; Webster, Sv; Hemington-Gorse, S

    2013-06-01

    Poster presentations are an important part of presenting scientific techniques and represent an integral part of conferences and meetings. Traditionally, paper format is used; however, in recent years electronic posters and other methods, such as incorporating a DVD player as part of a poster, have been successfully used. We describe and demonstrate the use of an augmented reality application for smartphones and tablets as a potential future addition to the presentation of scientific work and surgical techniques in poster format. This method allows the audience to view surgical techniques and research as 3D animation or video by using a trigger image in a poster/journal/text book via their smart device. The author used the free Aurasma© application available on both iOS and Android 2.2 and higher platforms from iTunes App Store and Google Play. Once installed, any user with a 3G or WiFi connection via a smart phone or tablet can subscribe to the Medical Illustration channel for free. The user can then scan the trigger image placed on a poster with a mobile device to view videos, animations or 3D data. Further interaction can direct the user to a website for more content. The author has trialled this method at a regional burns and plastic surgery centre and found it to be highly effective. The use of this novel method adds a new dimension to the presentation of scientific work at surgical and medical conferences and as part of journals and textbooks by permitting users to view scientific data and techniques on mobile devices as videos or as three dimensional environments at their own leisure.

  3. 21 CFR 880.2740 - Surgical sponge scale.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical sponge scale. 880.2740 Section 880.2740... Devices § 880.2740 Surgical sponge scale. (a) Identification. A surgical sponge scale is a nonelectrically powered device used to weigh surgical sponges that have been used to absorb blood during surgery so that...

  4. Assessing Technical Competence in Surgical Trainees: A Systematic Review.

    Science.gov (United States)

    Szasz, Peter; Louridas, Marisa; Harris, Kenneth A; Aggarwal, Rajesh; Grantcharov, Teodor P

    2015-06-01

    To systematically examine the literature describing the methods by which technical competence is assessed in surgical trainees. The last decade has witnessed an evolution away from time-based surgical education. In response, governing bodies worldwide have implemented competency-based education paradigms. The definition of competence, however, remains elusive, and the impact of these education initiatives in terms of assessment methods remains unclear. A systematic review examining the methods by which technical competence is assessed was conducted by searching MEDLINE, EMBASE, PsychINFO, and the Cochrane database of systematic reviews. Abstracts of retrieved studies were reviewed and those meeting inclusion criteria were selected for full review. Data were retrieved in a systematic manner, the validity and reliability of the assessment methods was evaluated, and quality was assessed using the Grading of Recommendations Assessment, Development and Evaluation classification. Of the 6814 studies identified, 85 studies involving 2369 surgical residents were included in this review. The methods used to assess technical competence were categorized into 5 groups; Likert scales (37), benchmarks (31), binary outcomes (11), novel tools (4), and surrogate outcomes (2). Their validity and reliability were mostly previously established. The overall Grading of Recommendations Assessment, Development and Evaluation for randomized controlled trials was high and low for the observational studies. The definition of technical competence continues to be debated within the medical literature. The methods used to evaluate technical competence predominantly include instruments that were originally created to assess technical skill. Very few studies identify standard setting approaches that differentiate competent versus noncompetent performers; subsequently, this has been identified as an area with great research potential.

  5. Development and validation of trauma surgical skills metrics: Preliminary assessment of performance after training.

    Science.gov (United States)

    Shackelford, Stacy; Garofalo, Evan; Shalin, Valerie; Pugh, Kristy; Chen, Hegang; Pasley, Jason; Sarani, Babak; Henry, Sharon; Bowyer, Mark; Mackenzie, Colin F

    2015-07-01

    Maintaining trauma-specific surgical skills is an ongoing challenge for surgical training programs. An objective assessment of surgical skills is needed. We hypothesized that a validated surgical performance assessment tool could detect differences following a training intervention. We developed surgical performance assessment metrics based on discussion with expert trauma surgeons, video review of 10 experts and 10 novice surgeons performing three vascular exposure procedures and lower extremity fasciotomy on cadavers, and validated the metrics with interrater reliability testing by five reviewers blinded to level of expertise and a consensus conference. We tested these performance metrics in 12 surgical residents (Year 3-7) before and 2 weeks after vascular exposure skills training in the Advanced Surgical Skills for Exposure in Trauma (ASSET) course. Performance was assessed in three areas as follows: knowledge (anatomic, management), procedure steps, and technical skills. Time to completion of procedures was recorded, and these metrics were combined into a single performance score, the Trauma Readiness Index (TRI). Wilcoxon matched-pairs signed-ranks test compared pretraining/posttraining effects. Mean time to complete procedures decreased by 4.3 minutes (from 13.4 minutes to 9.1 minutes). The performance component most improved by the 1-day skills training was procedure steps, completion of which increased by 21%. Technical skill scores improved by 12%. Overall knowledge improved by 3%, with 18% improvement in anatomic knowledge. TRI increased significantly from 50% to 64% with ASSET training. Interrater reliability of the surgical performance assessment metrics was validated with single intraclass correlation coefficient of 0.7 to 0.98. A trauma-relevant surgical performance assessment detected improvements in specific procedure steps and anatomic knowledge taught during a 1-day course, quantified by the TRI. ASSET training reduced time to complete vascular

  6. Discharge from an emergency department observation unit and a surgical assessment unit

    DEFF Research Database (Denmark)

    Schultz, Helen; Qvist, Niels; Backer Mogensen, Christian

    2014-01-01

    To investigate the experiences of patients with acute abdominal pain at discharge from an emergency department observation unit compared with discharge from a surgical assessment unit.......To investigate the experiences of patients with acute abdominal pain at discharge from an emergency department observation unit compared with discharge from a surgical assessment unit....

  7. MOJECT: MOTION ANALYSIS TO SUPPORT ASSESSMENT OF SURGICAL SKILLS

    NARCIS (Netherlands)

    Uineken, Ruben; Groot Jebbink, Erik; Halfwerk, F.R.; Bulten, Anne; Knoben, Peter; Roux, Moritz; Wicik, Ola; Groenier, Marleen

    2018-01-01

    Assessment of surgical skills is usually performed through direct observation by experts. This is subjective, expensive and requires assessor training. Motion analysis can support objective and cost-effective assessment. The aim of the current study is to design a low-cost, unobtrusive system for

  8. Extended score interval in the assessment of basic surgical skills.

    Science.gov (United States)

    Acosta, Stefan; Sevonius, Dan; Beckman, Anders

    2015-01-01

    The Basic Surgical Skills course uses an assessment score interval of 0-3. An extended score interval, 1-6, was proposed by the Swedish steering committee of the course. The aim of this study was to analyze the trainee scores in the current 0-3 scored version compared to a proposed 1-6 scored version. Sixteen participants, seven females and nine males, were evaluated in the current and proposed assessment forms by instructors, observers, and learners themselves during the first and second day. In each assessment form, 17 tasks were assessed. The inter-rater reliability between the current and the proposed score sheets were evaluated with intraclass correlation (ICC) with 95% confidence intervals (CI). The distribution of scores for 'knot tying' at the last time point and 'bowel anastomosis side to side' given by the instructors in the current assessment form showed that the highest score was given in 31 and 62%, respectively. No ceiling effects were found in the proposed assessment form. The overall ICC between the current and proposed score sheets after assessment by the instructors increased from 0.38 (95% CI 0.77-0.78) on Day 1 to 0.83 (95% CI 0.51-0.94) on Day 2. A clear ceiling effect of scores was demonstrated in the current assessment form, questioning its validity. The proposed score sheet provides more accurate scores and seems to be a better feedback instrument for learning technical surgical skills in the Basic Surgical Skills course.

  9. Assessment of surgeon fatigue by surgical simulators

    Directory of Open Access Journals (Sweden)

    Tuwairqi K

    2015-04-01

    Full Text Available Khaled Tuwairqi,1 Jessica H Selter,2 Shameema Sikder3 1College of Medicine, University of Utah, Salt Lake City, UT, 2Johns Hopkins School of Medicine, 3Wilmer Eye Institute, Johns Hopkins University, Baltimore, MD, USA Background: The impact of fatigue on surgical performance and its implications for patient care is a growing concern. While investigators have employed a number of different tools to measure the effect of fatigue on surgical performance, the use of the surgical simulator has been increasingly implemented for this purpose. The goal of this paper is to review the published literature to achieve a better understanding of evaluation of fatigue on performance as studied with surgical simulators. Methods: A PubMed and Cochrane search was conducted using the search terms “simulator”, “surgery”, and “fatigue”. In total, 50 papers were evaluated, and 20 studies were selected after application of exclusion criteria. Articles were excluded if they did not use the simulator to assess the impact of fatigue on surgeon performance. Systematic reviews and case reports were also excluded. Results: Surgeon fatigue led to a consistent decline in cognitive function in six studies. Technical skills were evaluated in 18 studies, and a detrimental impact was reported in nine studies, while the remaining nine studies showed either no change or positive results with regard to surgical skills after experience of fatigue. Two pharmacological intervention studies reversed the detrimental impact of fatigue on cognitive function, but no change or a worsening effect was recognized for technical skills. Conclusion: Simulators are increasingly being used to evaluate the impact of fatigue on the surgeon's performance. With regard to the impact of fatigue in this regard, studies have demonstrated a consistent decline in cognitive function and mixed outcomes for technical skills. Larger studies that relate the simulator's results to real surgical

  10. Self-assessment in laparoscopic surgical skills training: Is it reliable?

    Science.gov (United States)

    Ganni, Sandeep; Chmarra, Magdalena K; Goossens, Richard H M; Jakimowicz, Jack J

    2017-06-01

    The concept of self-assessment has been widely acclaimed for its role in the professional development cycle and self-regulation. In the field of medical education, self-assessment has been most used to evaluate the cognitive knowledge of students. The complexity of training and evaluation in laparoscopic surgery has previously acted as a barrier in determining the benefits self-assessment has to offer in comparison with other fields of medical education. Thirty-five surgical residents who attended the 2-day Laparoscopic Surgical Skills Grade 1 Level 1 curriculum were invited to participate from The Netherlands, India and Romania. The competency assessment tool (CAT) for laparoscopic cholecystectomy was used for self- and expert-assessment and the resulting distributions assessed. A comparison between the expert- and self-assessed aggregates of scores from the CAT agreed with previous studies. Uniquely to this study, the aggregates of individual sub-categories-'use of instruments'; 'tissue handling'; and errors 'within the component tasks' and the 'end product' from both self- and expert-assessments-were investigated. There was strong positive correlation (r s  > 0.5; p assessment in all categories with only the 'tissue handling' having a weaker correlation (r s  = 0.3; p = 0.04). The distribution of the mean of the differences between self-assessment and expert-assessment suggested no significant difference between the scores of experts and the residents in all categories except the 'end product' evaluation where the difference was significant (W = 119, p = 0.03). Self-assessment using the CAT form gives results that are consistently not different from expert-assessment when assessing one's proficiency in surgical skills. Areas where there was less agreement could be explained by variations in the level of training and understanding of the assessment criteria.

  11. A ferromagnetic surgical system reduces phrenic nerve injury in redo congenital cardiac surgery.

    Science.gov (United States)

    Shinkawa, Takeshi; Holloway, Jessica; Tang, Xinyu; Gossett, Jeffrey M; Imamura, Michiaki

    2017-05-01

    A ferromagnetic surgical system (FMwand®) is a new type of dissection device expected to reduce the risk of adjacent tissue damage. We reviewed 426 congenital cardiac operations with cardiopulmonary bypass through redo sternotomy to assess if this device prevented phrenic nerve injury. The ferromagnetic surgical system was used in 203 operations (47.7%) with regular electrocautery and scissors. The preoperative and operative details were similar between the operations with or without the ferromagnetic surgical system. The incidence of phrenic nerve injury was significantly lower with the ferromagnetic surgical system (0% vs 2.7%, P = 0.031). A logistic regression model showed that the use of the ferromagnetic surgical system was significantly associated with reduced odds of phrenic nerve injury (P < 0.001). © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Reducing post-surgical adhesions utilizing a drug-enhanced device: sodium carboxymethylcellulose aqueous gel/poly(p-dioxanone) and Tranilast

    International Nuclear Information System (INIS)

    Cui, Helen; Gensini, Michel; Kataria, Ram; Twaddle, Tricia; Zhang, John; Wadsworth, Scott; Cooper, Kevin; Petrilli, Janel; Rodgers, Kathleen; DiZerega, Gere

    2009-01-01

    Post-surgical adhesion formation has numerous deleterious side effects in a wide variety of surgical settings. Physical barriers used together with laparoscopy were developed to reduce tissue trauma seen with open procedures. However, despite surgeons' meticulous techniques and the use of such barriers, adhesion formation remains a serious clinical problem, creating complications that cost the health care system over $1 billion annually. Our laboratories have combined a previously marketed drug, Tranilast, with a sodium carboxymethylcellulose (NaCMC) gel in a sustained release formulation using poly(p-dioxanone) (PDO) to provide a locally delivered medicated device that significantly reduces adhesions. This paper describes the preparation of the gel and the sustained release formulation, its key physical properties, and its sustained release kinetics. Pre-clinical data on inhibition of adhesion formation by the sustained release poly(p-dioxanone)/sodium carboxymethylcellulose/Tranilast drug enhanced device are also presented.

  13. 21 CFR 876.4730 - Manual gastroenterology-urology surgical instrument and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual gastroenterology-urology surgical... OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Surgical Devices § 876.4730 Manual gastroenterology-urology surgical instrument and accessories. (a) Identification...

  14. Surgical removal of intra-abdominal intrauterine devices at one center in a 20-year period.

    Science.gov (United States)

    Ertopcu, Kenan; Nayki, Cenk; Ulug, Pasa; Nayki, Umit; Gultekin, Emre; Donmez, Aysegul; Yildirim, Yusuf

    2015-01-01

    To review 20 years of experience of the removal of intra-abdominal intrauterine devices (IUDs) and to compare the surgical methods used. In a retrospective study, charts dating from between September 1, 1992, and August 31, 2012, were reviewed. Patients were eligible for inclusion when they had an IUD surgically removed by minilaparotomy or laparoscopy at a tertiary referral center in Izmir, Turkey. Among the 36 eligible women, 18 (50%) had undergone laparoscopy and 18 (50%) had undergone minilaparotomy. Mean operation length was 55.3±6.3 minutes in the laparoscopy group and 29.1±4.2 minutes in the minilaparotomy group (P=0.008). Conversion to full laparotomy was necessary in 4 (22%) women in the laparoscopy group and 1 (6%) in the minilaparotomy group (P=0.02). Perioperative complications were observed in 5 (14%) women, with no difference in frequency between groups (P=0.09). Total cost of medical/surgical procedures was US$436.4±35.4 for the laparoscopy group and $323.4±21.3 for the minilaparotomy group (P=0.04). Minilaparotomy seems to be an important alternative to laparoscopy for the removal of intra-abdominal IUDs. This procedure should be an integral part of gynecologic surgical training. Copyright © 2014 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  15. Using Google Glass in Surgical Settings: Systematic Review.

    Science.gov (United States)

    Wei, Nancy J; Dougherty, Bryn; Myers, Aundria; Badawy, Sherif M

    2018-03-06

    In recent years, wearable devices have become increasingly attractive and the health care industry has been especially drawn to Google Glass because of its ability to serve as a head-mounted wearable device. The use of Google Glass in surgical settings is of particular interest due to the hands-free device potential to streamline workflow and maintain sterile conditions in an operating room environment. The aim is to conduct a systematic evaluation of the literature on the feasibility and acceptability of using Google Glass in surgical settings and to assess the potential benefits and limitations of its application. The literature was searched for articles published between January 2013 and May 2017. The search included the following databases: PubMed MEDLINE, Embase, Cumulative Index to Nursing and Allied Health Literature, PsycINFO (EBSCO), and IEEE Xplore. Two reviewers independently screened titles and abstracts and assessed full-text articles. Original research articles that evaluated the feasibility, usability, or acceptability of using Google Glass in surgical settings were included. This review was completed following the Preferred Reporting Results of Systematic Reviews and Meta-Analyses guidelines. Of the 520 records obtained, 31 met all predefined criteria and were included in this review. Google Glass was used in various surgical specialties. Most studies were in the United States (23/31, 74%) and all were conducted in hospital settings: 29 in adult hospitals (29/31, 94%) and two in children's hospitals (2/31, 7%). Sample sizes of participants who wore Google Glass ranged from 1 to 40. Of the 31 studies, 25 (81%) were conducted under real-time conditions or actual clinical care settings, whereas the other six (19%) were conducted under simulated environment. Twenty-six studies were pilot or feasibility studies (84%), three were case studies (10%), and two were randomized controlled trials (6%). The majority of studies examined the potential use of

  16. The role of multimedia in surgical skills training and assessment.

    Science.gov (United States)

    Shariff, Umar; Seretis, Charalampos; Lee, Doreen; Balasubramanian, Saba P

    2016-06-01

    Multimedia is an educational resource that can be used to supplement surgical skills training. The aim of this review was to determine the role of multimedia in surgical training and assessment by performing a systematic review of the literature. A systematic review for published articles was conducted on the following databases: PubMed/MEDLINE (1992 to November 2014), SCOPUS (1992 to November 2014) and EMBASE (1992 to November 2014). For each study the educational content, study design, surgical skill assessed and outcomes were recorded. A standard data extraction form was created to ensure systematic retrieval of relevant information. 21 studies were included; 14 randomized controlled trials (RCTs) and 7 non-randomized controlled trials (Non-RCTs). Technical skills were assessed in 7 RCTs and 3 non-RCTs; cognitive skills were assessed in 9 RCTs and 4 non-RCTs. In controlled studies, multimedia was associated with significant improvement in technical skills (4 studies; 4 RCTs) and cognitive skills (7 studies; 6 RCTs). In two studies multimedia was inferior in comparison to conventional teaching. Evaluation of multimedia (9 studies) demonstrated strongly favourable results. This review suggests that multimedia effectively facilitates both technical and cognitive skills acquisition and is well accepted as an educational resource. Copyright © 2015 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  17. Surgical robotics beyond enhanced dexterity instrumentation: a survey of machine learning techniques and their role in intelligent and autonomous surgical actions.

    Science.gov (United States)

    Kassahun, Yohannes; Yu, Bingbin; Tibebu, Abraham Temesgen; Stoyanov, Danail; Giannarou, Stamatia; Metzen, Jan Hendrik; Vander Poorten, Emmanuel

    2016-04-01

    Advances in technology and computing play an increasingly important role in the evolution of modern surgical techniques and paradigms. This article reviews the current role of machine learning (ML) techniques in the context of surgery with a focus on surgical robotics (SR). Also, we provide a perspective on the future possibilities for enhancing the effectiveness of procedures by integrating ML in the operating room. The review is focused on ML techniques directly applied to surgery, surgical robotics, surgical training and assessment. The widespread use of ML methods in diagnosis and medical image computing is beyond the scope of the review. Searches were performed on PubMed and IEEE Explore using combinations of keywords: ML, surgery, robotics, surgical and medical robotics, skill learning, skill analysis and learning to perceive. Studies making use of ML methods in the context of surgery are increasingly being reported. In particular, there is an increasing interest in using ML for developing tools to understand and model surgical skill and competence or to extract surgical workflow. Many researchers begin to integrate this understanding into the control of recent surgical robots and devices. ML is an expanding field. It is popular as it allows efficient processing of vast amounts of data for interpreting and real-time decision making. Already widely used in imaging and diagnosis, it is believed that ML will also play an important role in surgery and interventional treatments. In particular, ML could become a game changer into the conception of cognitive surgical robots. Such robots endowed with cognitive skills would assist the surgical team also on a cognitive level, such as possibly lowering the mental load of the team. For example, ML could help extracting surgical skill, learned through demonstration by human experts, and could transfer this to robotic skills. Such intelligent surgical assistance would significantly surpass the state of the art in surgical

  18. Review of emerging surgical robotic technology.

    Science.gov (United States)

    Peters, Brian S; Armijo, Priscila R; Krause, Crystal; Choudhury, Songita A; Oleynikov, Dmitry

    2018-04-01

    The use of laparoscopic and robotic procedures has increased in general surgery. Minimally invasive robotic surgery has made tremendous progress in a relatively short period of time, realizing improvements for both the patient and surgeon. This has led to an increase in the use and development of robotic devices and platforms for general surgery. The purpose of this review is to explore current and emerging surgical robotic technologies in a growing and dynamic environment of research and development. This review explores medical and surgical robotic endoscopic surgery and peripheral technologies currently available or in development. The devices discussed here are specific to general surgery, including laparoscopy, colonoscopy, esophagogastroduodenoscopy, and thoracoscopy. Benefits and limitations of each technology were identified and applicable future directions were described. A number of FDA-approved devices and platforms for robotic surgery were reviewed, including the da Vinci Surgical System, Sensei X Robotic Catheter System, FreeHand 1.2, invendoscopy E200 system, Flex® Robotic System, Senhance, ARES, the Single-Port Instrument Delivery Extended Research (SPIDER), and the NeoGuide Colonoscope. Additionally, platforms were reviewed which have not yet obtained FDA approval including MiroSurge, ViaCath System, SPORT™ Surgical System, SurgiBot, Versius Robotic System, Master and Slave Transluminal Endoscopic Robot, Verb Surgical, Miniature In Vivo Robot, and the Einstein Surgical Robot. The use and demand for robotic medical and surgical platforms is increasing and new technologies are continually being developed. New technologies are increasingly implemented to improve on the capabilities of previously established systems. Future studies are needed to further evaluate the strengths and weaknesses of each robotic surgical device and platform in the operating suite.

  19. "Reflection-Before-Practice" Improves Self-Assessment and End-Performance in Laparoscopic Surgical Skills Training.

    Science.gov (United States)

    Ganni, Sandeep; Botden, Sanne M B I; Schaap, Dennis P; Verhoeven, Bas H; Goossens, Richard H M; Jakimowicz, Jack J

    To establish whether a systematized approach to self-assessment in a laparoscopic surgical skills course improves accordance between expert- and self-assessment. A systematic training course in self-assessment using Competency Assessment Tool was introduced into the normal course of evaluation within a Laparoscopic Surgical Skills training course for the test group (n = 30). Differences between these and a control group (n = 30) who did not receive the additional training were assessed. Catharina Hospital, Eindhoven, The Netherlands (n = 27), and GSL Medical College, Rajahmundry, India (n = 33). Sixty postgraduate year 2 and 3 surgical residents who attended the 2-day Laparoscopic Surgical Skills grade 1 level 1 curriculum were invited to participate. The test group (n = 30) showed better accordance between expert- and self-assessment (difference of 1.5, standard deviation [SD] = 0.2 versus 3.83, SD = 0.6, p = 0.009) as well as half the number (7 versus 14) of cases of overreporting. Furthermore, the test group also showed higher overall mean performance (mean = 38.1, SD = 0.7 versus mean = 31.8, SD = 1.0, p assessment can be viewed as responsible for this and can be seen as "reflection-before-practice" within the framework of reflective practice as defined by Donald Schon. Our results suggest that "reflection-before-practice" in implementing self-assessment is an important step in the development of surgical skills, yielding both better understanding of one's strengths and weaknesses and also improving overall performance. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  20. Detection of the spatial accuracy of an O-arm in the region of surgical interest

    Science.gov (United States)

    Koivukangas, Tapani; Katisko, Jani P. A.; Koivukangsa, John P.

    2013-03-01

    Medical imaging is an essential component of a wide range of surgical procedures1. For image guided surgical (IGS) procedures, medical images are the main source of information2. The IGS procedures rely largely on obtained image data, so the data needs to provide differentiation between normal and abnormal tissues, especially when other surgical guidance devices are used in the procedures. The image data also needs to provide accurate spatial representation of the patient3. This research has concentrated on the concept of accuracy assessment of IGS devices to meet the needs of quality assurance in the hospital environment. For this purpose, two precision engineered accuracy assessment phantoms have been developed as advanced materials and methods for the community. The phantoms were designed to mimic the volume of a human head as the common region of surgical interest (ROSI). This paper introduces the utilization of the phantoms in spatial accuracy assessment of a commercial surgical 3D CT scanner, the O-Arm. The study presents methods and results of image quality detection of possible geometrical distortions in the region of surgical interest. The results show that in the pre-determined ROSI there are clear image distortion and artefacts using too high imaging parameters when scanning the objects. On the other hand, when using optimal parameters, the O-Arm causes minimal error in IGS accuracy. The detected spatial inaccuracy of the O-Arm with used parameters was in the range of less than 1.00 mm.

  1. Device for assessing radio-photoluminescence glasses

    International Nuclear Information System (INIS)

    Hoegl, A.; Schubert, K.

    1979-01-01

    The UV light irradiating the glass and the luminescence light caused by the UV light are collected in separate measuring paths. In order to correct the affect of changes of intensity of the UV light source on the amount of luminescence, both measuring paths are connected by programmed control, a comparison device and a correcting device. There are integrating stages in both measuring paths, which are followed by analogue digital converters with an assessment device. (DG) [de

  2. Surgical repair of a celiac artery aneurysm using a sutureless proximal anastomosis device

    Directory of Open Access Journals (Sweden)

    Tetsuro Uchida, MD, PhD

    2017-12-01

    Full Text Available Some celiac artery aneurysms are not suitable for endovascular therapy. We describe the case of a 63-year-old man with a celiac trunk aneurysm extending to the hepatosplenic bifurcation. The aneurysm was resected and oversewn at the origin from the abdominal aorta. A saphenous vein bypass from the supraceliac aorta to the celiac artery bifurcation was performed using a sutureless anastomotic device (PAS-Port system; Cardica, Redwood City, Calif to create the proximal anastomosis, eliminating the need for aortic clamping. This system is thought to make direct proximal aortic anastomosis safe and easy in patients requiring surgical reconstruction of celiac artery aneurysms.

  3. Development of a Classification Scheme for Examining Adverse Events Associated with Medical Devices, Specifically the DaVinci Surgical System as Reported in the FDA MAUDE Database.

    Science.gov (United States)

    Gupta, Priyanka; Schomburg, John; Krishna, Suprita; Adejoro, Oluwakayode; Wang, Qi; Marsh, Benjamin; Nguyen, Andrew; Genere, Juan Reyes; Self, Patrick; Lund, Erik; Konety, Badrinath R

    2017-01-01

    To examine the Manufacturer and User Facility Device Experience Database (MAUDE) database to capture adverse events experienced with the Da Vinci Surgical System. In addition, to design a standardized classification system to categorize the complications and machine failures associated with the device. Overall, 1,057,000 DaVinci procedures were performed in the United States between 2009 and 2012. Currently, no system exists for classifying and comparing device-related errors and complications with which to evaluate adverse events associated with the Da Vinci Surgical System. The MAUDE database was queried for events reports related to the DaVinci Surgical System between the years 2009 and 2012. A classification system was developed and tested among 14 robotic surgeons to associate a level of severity with each event and its relationship to the DaVinci Surgical System. Events were then classified according to this system and examined by using Chi-square analysis. Two thousand eight hundred thirty-seven events were identified, of which 34% were obstetrics and gynecology (Ob/Gyn); 19%, urology; 11%, other; and 36%, not specified. Our classification system had moderate agreement with a Kappa score of 0.52. Using our classification system, we identified 75% of the events as mild, 18% as moderate, 4% as severe, and 3% as life threatening or resulting in death. Seventy-seven percent were classified as definitely related to the device, 15% as possibly related, and 8% as not related. Urology procedures compared with Ob/Gyn were associated with more severe events (38% vs 26%, p tool with moderate inter-rater agreement that can be used to better understand device-related adverse events. The majority of robotic related events were mild but associated with the device.

  4. Automated surgical skill assessment in RMIS training.

    Science.gov (United States)

    Zia, Aneeq; Essa, Irfan

    2018-05-01

    Manual feedback in basic robot-assisted minimally invasive surgery (RMIS) training can consume a significant amount of time from expert surgeons' schedule and is prone to subjectivity. In this paper, we explore the usage of different holistic features for automated skill assessment using only robot kinematic data and propose a weighted feature fusion technique for improving score prediction performance. Moreover, we also propose a method for generating 'task highlights' which can give surgeons a more directed feedback regarding which segments had the most effect on the final skill score. We perform our experiments on the publicly available JHU-ISI Gesture and Skill Assessment Working Set (JIGSAWS) and evaluate four different types of holistic features from robot kinematic data-sequential motion texture (SMT), discrete Fourier transform (DFT), discrete cosine transform (DCT) and approximate entropy (ApEn). The features are then used for skill classification and exact skill score prediction. Along with using these features individually, we also evaluate the performance using our proposed weighted combination technique. The task highlights are produced using DCT features. Our results demonstrate that these holistic features outperform all previous Hidden Markov Model (HMM)-based state-of-the-art methods for skill classification on the JIGSAWS dataset. Also, our proposed feature fusion strategy significantly improves performance for skill score predictions achieving up to 0.61 average spearman correlation coefficient. Moreover, we provide an analysis on how the proposed task highlights can relate to different surgical gestures within a task. Holistic features capturing global information from robot kinematic data can successfully be used for evaluating surgeon skill in basic surgical tasks on the da Vinci robot. Using the framework presented can potentially allow for real-time score feedback in RMIS training and help surgical trainees have more focused training.

  5. Open core control software for surgical robots.

    Science.gov (United States)

    Arata, Jumpei; Kozuka, Hiroaki; Kim, Hyung Wook; Takesue, Naoyuki; Vladimirov, B; Sakaguchi, Masamichi; Tokuda, Junichi; Hata, Nobuhiko; Chinzei, Kiyoyuki; Fujimoto, Hideo

    2010-05-01

    In these days, patients and doctors in operation room are surrounded by many medical devices as resulting from recent advancement of medical technology. However, these cutting-edge medical devices are working independently and not collaborating with each other, even though the collaborations between these devices such as navigation systems and medical imaging devices are becoming very important for accomplishing complex surgical tasks (such as a tumor removal procedure while checking the tumor location in neurosurgery). On the other hand, several surgical robots have been commercialized, and are becoming common. However, these surgical robots are not open for collaborations with external medical devices in these days. A cutting-edge "intelligent surgical robot" will be possible in collaborating with surgical robots, various kinds of sensors, navigation system and so on. On the other hand, most of the academic software developments for surgical robots are "home-made" in their research institutions and not open to the public. Therefore, open source control software for surgical robots can be beneficial in this field. From these perspectives, we developed Open Core Control software for surgical robots to overcome these challenges. In general, control softwares have hardware dependencies based on actuators, sensors and various kinds of internal devices. Therefore, these control softwares cannot be used on different types of robots without modifications. However, the structure of the Open Core Control software can be reused for various types of robots by abstracting hardware dependent parts. In addition, network connectivity is crucial for collaboration between advanced medical devices. The OpenIGTLink is adopted in Interface class which plays a role to communicate with external medical devices. At the same time, it is essential to maintain the stable operation within the asynchronous data transactions through network. In the Open Core Control software, several

  6. Assessment scale of risk for surgical positioning injuries.

    Science.gov (United States)

    Lopes, Camila Mendonça de Moraes; Haas, Vanderlei José; Dantas, Rosana Aparecida Spadoti; Oliveira, Cheila Gonçalves de; Galvão, Cristina Maria

    2016-08-29

    to build and validate a scale to assess the risk of surgical positioning injuries in adult patients. methodological research, conducted in two phases: construction and face and content validation of the scale and field research, involving 115 patients. the Risk Assessment Scale for the Development of Injuries due to Surgical Positioning contains seven items, each of which presents five subitems. The scale score ranges between seven and 35 points in which, the higher the score, the higher the patient's risk. The Content Validity Index of the scale corresponded to 0.88. The application of Student's t-test for equality of means revealed the concurrent criterion validity between the scores on the Braden scale and the constructed scale. To assess the predictive criterion validity, the association was tested between the presence of pain deriving from surgical positioning and the development of pressure ulcer, using the score on the Risk Assessment Scale for the Development of Injuries due to Surgical Positioning (pposicionamiento quirúrgico en pacientes adultos. investigación metodológica, conducida en dos etapas: construcción y validación de faz y de contenido de la escala e investigación de campo, con la participación de 115 pacientes. la Escala de Evaluación de Riesgo para el Desarrollo de Lesiones Debidas al Posicionamiento Quirúrgico contiene siete ítems, siendo que cada uno presenta cinco subítems. La puntuación de esa escala varia de siete a 35 puntos en que, cuanto mayor la puntuación, mayor el riesgo del paciente. El Índice de Validez de Contenido de la escala fue 0,88. Mediante la aplicación de la prueba t de Student, para igualdad de medias, fue constatada validez de criterio concurrente entre los scores de la escala de Braden y de la escala construida. Para evaluar la validez de criterio predictiva, fue testada la asociación de la presencia de dolor debido al posicionamiento quirúrgico y el desarrollo de úlcera por presión con el score de

  7. Twelve tips for assessing surgical performance and use of technical assessment scales

    DEFF Research Database (Denmark)

    Strandbygaard, Jeanett; Scheele, Fedde; Sørensen, Jette Led

    2017-01-01

    Using validated assessment scales for technical competence can help structure and standardize assessment and feedback for both the trainee and the supervisor and thereby avoid bias and drive learning. Correct assessment of operative skills can establish learning curves and allow adequate monitoring....... However, the assessment of surgical performance is not an easy task, since it includes many proxy parameters, which are hard to measure. Although numerous technical assessment scales exist, both within laparoscopic and open surgery, the validity evidence is often sparse, and this can raise doubts about...... reliability and educational outcome. Furthermore, the implementation of technical assessment scales varies due to several obstacles and doubts about accurate use. In this 12-tips article, we aim to give the readers a critical and useful appraisal of some of the common questions and misunderstandings regarding...

  8. Catheter for Cleaning Surgical Optics During Surgical Procedures: A Possible Solution for Residue Buildup and Fogging in Video Surgery.

    Science.gov (United States)

    de Abreu, Igor Renato Louro Bruno; Abrão, Fernando Conrado; Silva, Alessandra Rodrigues; Corrêa, Larissa Teresa Cirera; Younes, Riad Nain

    2015-05-01

    Currently, there is a tendency to perform surgical procedures via laparoscopic or thoracoscopic access. However, even with the impressive technological advancement in surgical materials, such as improvement in quality of monitors, light sources, and optical fibers, surgeons have to face simple problems that can greatly hinder surgery by video. One is the formation of "fog" or residue buildup on the lens, causing decreased visibility. Intracavitary techniques for cleaning surgical optics and preventing fog formation have been described; however, some of these techniques employ the use of expensive and complex devices designed solely for this purpose. Moreover, these techniques allow the cleaning of surgical optics when they becomes dirty, which does not prevent the accumulation of residue in the optics. To solve this problem we have designed a device that allows cleaning the optics with no surgical stops and prevents the fogging and residue accumulation. The objective of this study is to evaluate through experimental testing the effectiveness of a simple device that prevents the accumulation of residue and fogging of optics used in surgical procedures performed through thoracoscopic or laparoscopic access. Ex-vivo experiments were performed simulating the conditions of residue presence in surgical optics during a video surgery. The experiment consists in immersing the optics and catheter set connected to the IV line with crystalloid solution in three types of materials: blood, blood plus fat solution, and 200 mL of distilled water and 1 vial of methylene blue. The optics coupled to the device were immersed in 200 mL of each type of residue, repeating each immersion 10 times for each distinct residue for both thirty and zero degrees optics, totaling 420 experiments. A success rate of 98.1% was observed after the experiments, in these cases the device was able to clean and prevent the residue accumulation in the optics.

  9. Toward an objective assessment of technical skills: a national survey of surgical program directors in Saudi Arabia.

    Science.gov (United States)

    Alkhayal, Abdullah; Aldhukair, Shahla; Alselaim, Nahar; Aldekhayel, Salah; Alhabdan, Sultan; Altaweel, Waleed; Magzoub, Mohi Elden; Zamakhshary, Mohammed

    2012-01-01

    After almost a decade of implementing competency-based programs in postgraduate training programs, the assessment of technical skills remains more subjective than objective. National data on the assessment of technical skills during surgical training are lacking. We conducted this study to document the assessment tools for technical skills currently used in different surgical specialties, their relationship with remediation, the recommended tools from the program directors' perspective, and program directors' attitudes toward the available objective tools to assess technical skills. This study was a cross-sectional survey of surgical program directors (PDs). The survey was initially developed using a focus group and was then sent to 116 PDs. The survey contains demographic information about the program, the objective assessment tools used, and the reason for not using assessment tools. The last section discusses the recommended tools to be used from the PDs' perspective and the PDs' attitude and motivation to apply these tools in each program. The associations between the responses to the assessment questions and remediation were statistically evaluated. Seventy-one (61%) participants responded. Of the respondents, 59% mentioned using only nonstandardized, subjective, direct observation for technical skills assessment. Sixty percent use only summative evaluation, whereas 15% perform only formative evaluations of their residents, and the remaining 22% conduct both summative and formative evaluations of their residents' technical skills. Operative portfolios are kept by 53% of programs. The percentage of programs with mechanisms for remediation is 29% (19 of 65). The survey showed that surgical training programs use different tools to assess surgical skills competency. Having a clear remediation mechanism was highly associated with reporting remediation, which reflects the capability to detect struggling residents. Surgical training leadership should invest more in

  10. Crowd-sourced assessment of technical skills: an adjunct to urology resident surgical simulation training.

    Science.gov (United States)

    Holst, Daniel; Kowalewski, Timothy M; White, Lee W; Brand, Timothy C; Harper, Jonathan D; Sorenson, Mathew D; Kirsch, Sarah; Lendvay, Thomas S

    2015-05-01

    Crowdsourcing is the practice of obtaining services from a large group of people, typically an online community. Validated methods of evaluating surgical video are time-intensive, expensive, and involve participation of multiple expert surgeons. We sought to obtain valid performance scores of urologic trainees and faculty on a dry-laboratory robotic surgery task module by using crowdsourcing through a web-based grading tool called Crowd Sourced Assessment of Technical Skill (CSATS). IRB approval was granted to test the technical skills grading accuracy of Amazon.com Mechanical Turk™ crowd-workers compared to three expert faculty surgeon graders. The two groups assessed dry-laboratory robotic surgical suturing performances of three urology residents (PGY-2, -4, -5) and two faculty using three performance domains from the validated Global Evaluative Assessment of Robotic Skills assessment tool. After an average of 2 hours 50 minutes, each of the five videos received 50 crowd-worker assessments. The inter-rater reliability (IRR) between the surgeons and crowd was 0.91 using Cronbach's alpha statistic (confidence intervals=0.20-0.92), indicating an agreement level between the two groups of "excellent." The crowds were able to discriminate the surgical level, and both the crowds and the expert faculty surgeon graders scored one senior trainee's performance above a faculty's performance. Surgery-naive crowd-workers can rapidly assess varying levels of surgical skill accurately relative to a panel of faculty raters. The crowds provided rapid feedback and were inexpensive. CSATS may be a valuable adjunct to surgical simulation training as requirements for more granular and iterative performance tracking of trainees become mandated and commonplace.

  11. Objective assessment of surgical performance and its impact on a national selection programme of candidates for higher surgical training in plastic surgery.

    LENUS (Irish Health Repository)

    Carroll, Sean M

    2012-02-01

    OBJECTIVE: The objective of this study was to develop and validate a transparent, fair and objective assessment programme for the selection of surgical trainees into higher surgical training (HST) in plastic surgery in the Republic of Ireland. METHODS: Thirty-four individuals applied for HST in plastic surgery at the Royal College of Surgeons in Ireland (RCSI) in the academic years 2005-2006 and 2006-2007. Eighteen were short-listed for interview and further assessment. All applicants were required to report on their undergraduate educational performance and their postgraduate professional development. Short-listed applicants completed validated objective assessment simulations of surgical skills, an interview and assessment of their suitability for a career in surgery. RESULTS: When applicants\\' short-listing scores were combined with their interview scores and assessment of their suitability for a career in surgery, individuals who were selected for HST in plastic surgery performed significantly better than those who were not (P<0.002). However, when the assessment of technical skills scores were added the significance level of this difference increased further (P<0.0001) as did the statistical power of the difference to 99.9%, thus increasing the robustness of the selection package. CONCLUSION: The results from this study suggest that the assessment protocol we used to select individuals for HST in plastic surgery reliably and statistically significantly discriminated between the performances of candidates.

  12. Developing an Assessment (Tool) for Touch Screen Devices.

    Science.gov (United States)

    Danial-Saad, Alexandra; Chiari, Lorenzo

    2017-01-01

    Touch screen devices have become prevalent in our lives. Assistive technology experts working with people with disabilities face difficulty in understanding and assessing the problems experienced by individuals with disabilities in operating touch screen devices. This paper presents the processes of collecting and creating the required knowledge needed for assessing the user's skills for operating various touch screen devices, in order to develop an application for assessing the user's abilities and limitations. A six step procedure was used to collect and validate the required knowledge for the assessment from a multidisciplinary team. To determine the agreement levels between the experts, content validity was calculated. To test correlation between the experts from the different disciplines, a comparison was made between the discipline groups and their choice of specific skills/measurements. The final number of domains and skills/measurements was 15 domains and 50 skills/measurements. The result of Cronbach's α test for the final assessment questionnaire (50 skills/measurements) was 0.94, which indicates a high degree of reliability. The results of Kruskal-Wallis test showed the lack of any significant difference between agreements of the clinicians and the technicians groups, but significant differences were found between the educators and the clinicians groups. Each of the skills appearing in the final questionnaire was illustrated in a flowchart in preparation for developing the assessment (tool) for using touch screen devices.

  13. Can we assess healing of surgically treated long bone fractures on radiograph?

    Science.gov (United States)

    Perlepe, V; Omoumi, P; Larbi, A; Putineanu, D; Dubuc, J-E; Schubert, T; Vande Berg, B

    2018-06-01

    To determine the frequency and causes for limitations in the radiographic evaluation of surgically treated long bone fractures. Six readers separately scored 140 sets of antero-posterior (AP) and lateral radiographs of surgically treated long bone fractures, using a radiographic union score (RUS). We determined the rate of assessability of the fracture edges at each of the four cortical segments (n=560) seen tangentially on the two radiographs and the causes for non-assessability. The rate of feasibility of the RUS (more than two fracture edges assessable per fracture) was determined and compared according to different parameters. Fracture edges were visible in 71% to 81% of the 560 cortical segments. Metal hardware superimposition was the most frequent cause for non-assessability (79-95%). RUS values could be calculated in 58% to 75% of fractures. Scoring was statistically significantly less frequently calculable in plated (31-56%) than in nailed fractures (90-97%), in distal (47-61%) than in proximal (78-89%) bones and in upper (27-49%) than in lower (76-91%) limb bones (P≤0.01). The type of stabilization hardware is the main limiting factor in the radiographic assessment of surgically treated long bone fractures. Scoring was feasible in only 31% to 56% of plated fractures. Copyright © 2018 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  14. Toward an objective assessment of technical skills: a national survey of surgical program directors in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Alkhayal A

    2012-10-01

    Full Text Available Abdullah Alkhayal,1 Shahla Aldhukair,2 Nahar Alselaim,1 Salah Aldekhayel,1 Sultan Alhabdan,1 Waleed Altaweel,3 Mohi Elden Magzoub,4 Mohammed Zamakhshary1,21Department of Surgery, King Saud bin Abdulaziz University for Health Sciences, Riyadh, Saudi Arabia; 2Public Health Section, King Abdullah International Medical Research Center, Riyadh, Saudi Arabia; 3Urology Department, King Faisal Specialist Hospital and Research Center, Riyadh, Saudi Arabia; 4Department of Medical Education, King Saud bin Abdulaziz University for Health Sciences, Riyadh, Saudi ArabiaBackground: After almost a decade of implementing competency-based programs in postgraduate training programs, the assessment of technical skills remains more subjective than objective. National data on the assessment of technical skills during surgical training are lacking. We conducted this study to document the assessment tools for technical skills currently used in different surgical specialties, their relationship with remediation, the recommended tools from the program directors’ perspective, and program directors’ attitudes toward the available objective tools to assess technical skills.Methods: This study was a cross-sectional survey of surgical program directors (PDs. The survey was initially developed using a focus group and was then sent to 116 PDs. The survey contains demographic information about the program, the objective assessment tools used, and the reason for not using assessment tools. The last section discusses the recommended tools to be used from the PDs’ perspective and the PDs’ attitude and motivation to apply these tools in each program. The associations between the responses to the assessment questions and remediation were statistically evaluated.Results: Seventy-one (61% participants responded. Of the respondents, 59% mentioned using only nonstandardized, subjective, direct observation for technical skills assessment. Sixty percent use only summative

  15. General and acute care surgical procedures in patients with left ventricular assist devices.

    Science.gov (United States)

    Arnaoutakis, George J; Bittle, Gregory J; Allen, Jeremiah G; Weiss, Eric S; Alejo, Jennifer; Baumgartner, William A; Shah, Ashish S; Wolfgang, Christopher L; Efron, David T; Conte, John V

    2014-04-01

    Left ventricular assist devices (LVADs) have become common as a bridge to heart transplant as well as destination therapy. Acute care surgical (ACS) problems in this population are prevalent but remain ill-defined. Therefore, we reviewed our experience with ACS interventions in LVAD patients. A total of 173 patients who received HeartMate(®) XVE or HeartMate(®) II (HMII) LVADs between December 2001 and March 2010 were studied. Patient demographics, presentation of ACS problem, operative intervention, co-morbidities, transplantation, complications, and survival were analyzed. A total of 47 (27 %) patients underwent 67 ACS procedures at a median of 38 days after device implant (interquartile range 15-110), with a peri-operative mortality rate of 5 % (N = 3). Demographics, device type, and acuity were comparable between the ACS and non-ACS groups. A total of 21 ACS procedures were performed emergently, eight were urgent, and 38 were elective. Of 29 urgent and emergent procedures, 28 were for abdominal pathology. In eight patients, the cause of the ACS problem was related to LVADs or anticoagulation. Cumulative survival estimates revealed no survival differences if patients underwent ACS procedures (p = 0.17). Among HMII patients, transplantation rates were unaffected by an ACS intervention (p = 0.2). ACS problems occur frequently in LVAD patients and are not associated with adverse outcomes in HMII patients. The acute care surgeon is an integral member of a comprehensive approach to effective LVAD management.

  16. Workplace-based assessment in surgical training: experiences from the Intercollegiate Surgical Curriculum Programme.

    Science.gov (United States)

    Eardley, Ian; Bussey, Maria; Woodthorpe, Adrian; Munsch, Chris; Beard, Jonathan

    2013-06-01

    The Intercollegiate Surgical Curriculum Programme was launched in the United Kingdom in 2007. At its heart was the reliance upon clear, defined curricula, competence-based training and the use of workplace-based assessments to assess the competence. The principle assessments used were Case-based Discussion, Procedure-based Assessments (PBA), Direct Observation of Procedural Skills, and Clinical Evaluation Exercise and a Multisource Feedback tool. We report the initial experience with that system, and most importantly, the experience with workplace-based assessment. Themes include issues around faculty development, misuse of assessments, inappropriate timing of assessments, concerns about validity and reliability of the assessments and concerns about the actual process of workplace-based assessments. Of the assessments, the PBA performed best. As a consequence, there has been an increased focus upon faculty development, while some of the assessments have been redesigned in line with the PBA. A global rating scale has been introduced that uses clinical anchors. The rating scales have also been altered with a reduction in the number of ratings while an enhanced description of the complexity of the case has been introduced within the Case-based Discussion and the Clinical Evaluation Exercise. A re-evaluation will take place in the near future. © 2013 The Authors. ANZ Journal of Surgery © 2013 Royal Australasian College of Surgeons.

  17. High-frequency ultrasound in carpal tunnel syndrome: assessment of patient eligibility for surgical treatment

    Directory of Open Access Journals (Sweden)

    Katarzyna Kapuścińska

    2015-09-01

    Full Text Available Carpal tunnel syndrome (CTS is the most common entrapment neuropathy and a frequent cause of sick leaves because of work-related hand overload. That is why an early diagnosis and adequate treatment (conservative or surgical are essential for optimal patient management. Aim: The aim of the study is to assess the usefulness of high-frequency ultrasound in CTS for the assessment of patient eligibility for surgical treatment. Material and methods: The study involved 62 patients (50 women and 12 men, aged 28–70, mean age 55.2 with scheduled surgeries of CTS on the basis of clinical symptoms, physical examination performed by a neurosurgeon and a positive result of EMG testing. The ultrasound examinations of the wrist were performed in all these patients. On the basis of the collected data, the author has performed multiple analyses to confi rm the usefulness of ultrasound imaging in assessing patient eligibility for surgical treatment of CTS. Results: US examinations showed evidence of median nerve compression at the level of the carpal tunnel in all of the examined patients. This was further confi rmed during surgical procedures. The mean value of the cross-sectional area at the proximal part of the pisiform bone was 17.45 mm2 (min. 12 mm2 , max. 31 mm2 . Nerve hypoechogenicity proximal to the nerve compression site was visible in all 62 patients (100%. Increased nerve vascularity on the transverse section was present in 50 patients (80.65%. Conclusions: Ultrasonography with the use of high-frequency transducers is a valuable diagnostic tool both for assessing patient eligibility for surgical treatment of CTS, and in postoperative assessment of the treatment efficacy.

  18. Knowing the operative game plan: a novel tool for the assessment of surgical procedural knowledge.

    Science.gov (United States)

    Balayla, Jacques; Bergman, Simon; Ghitulescu, Gabriela; Feldman, Liane S; Fraser, Shannon A

    2012-08-01

    What is the source of inadequate performance in the operating room? Is it a lack of technical skills, poor judgment or a lack of procedural knowledge? We created a surgical procedural knowledge (SPK) assessment tool and evaluated its use. We interviewed medical students, residents and training program staff on SPK assessment tools developed for 3 different common general surgery procedures: inguinal hernia repair with mesh in men, laparoscopic cholecystectomy and right hemicolectomy. The tools were developed as a step-wise assessment of specific surgical procedures based on techniques described in a current surgical text. We compared novice (medical student to postgraduate year [PGY]-2) and expert group (PGY-3 to program staff) scores using the Mann-Whitney U test. We calculated the total SPK score and defined a cut-off score using receiver operating characteristic analysis. In all, 5 participants in 7 different training groups (n = 35) underwent an interview. Median scores for each procedure and overall SPK scores increased with experience. The median SPK for novices was 54.9 (95% confidence interval [CI] 21.6-58.8) compared with 98.05 (95% CP 94.1-100.0) for experts (p = 0.012). The SPK cut-off score of 93.1 discriminates between novice and expert surgeons. Surgical procedural knowledge can reliably be assessed using our SPK assessment tool. It can discriminate between novice and expert surgeons for common general surgical procedures. Future studies are planned to evaluate its use for more complex procedures.

  19. Assessment of communication, professionalism, and surgical skills in an objective structured performance-related examination (OSPRE): a psychometric study.

    Science.gov (United States)

    Ponton-Carss, Alicia; Hutchison, Carol; Violato, Claudio

    2011-10-01

    The purpose of this study was to investigate the reliability and validity of a performance assessment of communication, professionalism, and surgical skills competencies for surgery residents. Fourteen residents from the general surgery program of the University of Calgary were assessed in 7 surgical simulation stations that included communication and professionalism skills. The internal consistency reliability of the checklists and global rating scales combined was adequate for communication (α = .75-.92) and surgical skills (α = .86-.96), but not for professionalism (α = 0). There was evidence of validity as surgical skills performance improved as a function of postgraduate year level but not for the professionalism checklist. Surgical skills and communication correlated in the 2 stations assessed (r = .55 and .57; P communication skills. Further instrument development is required to assess professionalism in a structured examination context. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Assessment of surgical portosystemic shunts and associated complications: The diagnostic and therapeutic role of radiologists

    Energy Technology Data Exchange (ETDEWEB)

    Taslakian, Bedros, E-mail: btaslakian@gmail.com [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Faraj, Walid, E-mail: wf07@aub.edu.lb [Department of General Surgery, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Khalife, Mohammad, E-mail: mk12@aub.edu.lb [Department of General Surgery, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Al-Kutoubi, Aghiad, E-mail: mk00@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); El-Merhi, Fadi, E-mail: fe19@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Saade, Charbel, E-mail: cs39@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Hallal, Ali, E-mail: ah05@aub.edu.lb [Department of General Surgery, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon); Haydar, Ali, E-mail: ah24@aub.edu.lb [Department of Radiology, American University of Beirut Medical Center, Riad El-Solh 1107 2020—PO Box: 11-0236, Beirut (Lebanon)

    2015-08-15

    Highlights: • Portal hypertension is the pathological increase in portal venous pressure. • Surgical portosystemic shunting is an accepted methods to decrease portal venous pressure. • Surgical portosystemic shunts are divided into selective and nonselective. • Shunt thrombosis is a serious complication, resulting in shunt dysfunction. • Imaging is essential in the assessment of the shunt function and anatomy. - Abstract: Surgical portosystemic shunting, the formation of a vascular connection between the portal and systemic venous circulation, has been used as a treatment to reduce portal venous pressure. Although the use of portosystemic shunt surgery in the management of portal hypertension has declined during the past decade in favour of alternative therapies, and subsequently surgeons and radiologists became less familiar with the procedure, it remains a well-established treatment. Knowledge of different types of surgical portosystemic shunts, their pathophysiology and complications will help radiologists improve communication with surgeons and enhance their understanding of the diagnostic and therapeutic role of radiology in the assessment and management of these shunts. Optimal assessment of the shunt is essential to determine its patency and allow timely intervention. Both non-invasive and invasive imaging modalities complement each other in the evaluation of surgical portosystemic shunts. Interventional radiology plays an important role in the management of complications, such as shunt thrombosis and stenosis. This article describes the various types of surgical portosystemic shunts, explains the anatomy and pathophysiology of these shunts, illustrates the pearls and pitfalls of different imaging modalities in the assessment of these shunts and demonstrates the role of radiologists in the interventional management of complications.

  1. Assessment of surgical portosystemic shunts and associated complications: The diagnostic and therapeutic role of radiologists

    International Nuclear Information System (INIS)

    Taslakian, Bedros; Faraj, Walid; Khalife, Mohammad; Al-Kutoubi, Aghiad; El-Merhi, Fadi; Saade, Charbel; Hallal, Ali; Haydar, Ali

    2015-01-01

    Highlights: • Portal hypertension is the pathological increase in portal venous pressure. • Surgical portosystemic shunting is an accepted methods to decrease portal venous pressure. • Surgical portosystemic shunts are divided into selective and nonselective. • Shunt thrombosis is a serious complication, resulting in shunt dysfunction. • Imaging is essential in the assessment of the shunt function and anatomy. - Abstract: Surgical portosystemic shunting, the formation of a vascular connection between the portal and systemic venous circulation, has been used as a treatment to reduce portal venous pressure. Although the use of portosystemic shunt surgery in the management of portal hypertension has declined during the past decade in favour of alternative therapies, and subsequently surgeons and radiologists became less familiar with the procedure, it remains a well-established treatment. Knowledge of different types of surgical portosystemic shunts, their pathophysiology and complications will help radiologists improve communication with surgeons and enhance their understanding of the diagnostic and therapeutic role of radiology in the assessment and management of these shunts. Optimal assessment of the shunt is essential to determine its patency and allow timely intervention. Both non-invasive and invasive imaging modalities complement each other in the evaluation of surgical portosystemic shunts. Interventional radiology plays an important role in the management of complications, such as shunt thrombosis and stenosis. This article describes the various types of surgical portosystemic shunts, explains the anatomy and pathophysiology of these shunts, illustrates the pearls and pitfalls of different imaging modalities in the assessment of these shunts and demonstrates the role of radiologists in the interventional management of complications

  2. Central-Approach Surgical Repair of Coarctation of the Aorta with a Back-up Left Ventricular Assist Device for an Infant Presenting with Severe Left Ventricular Dysfunction

    Directory of Open Access Journals (Sweden)

    Tae Hoon Kim

    2015-12-01

    Full Text Available A two-month-old infant presented with coarctation of the aorta, severe left ventricular dysfunction, and moderate to severe mitral regurgitation. Through median sternotomy, the aortic arch was repaired under cardiopulmonary bypass and regional cerebral perfusion. The patient was postoperatively supported with a left ventricular assist device for five days. Left ventricular function gradually improved, eventually recovering with the concomitant regression of mitral regurgitation. Prompt surgical repair of coarctation of the aorta is indicated for patients with severe left ventricular dysfunction. A central approach for surgical repair with a back-up left ventricular assist device is a safe and effective treatment strategy for these patients.

  3. Central-Approach Surgical Repair of Coarctation of the Aorta with a Back-up Left Ventricular Assist Device for an Infant Presenting with Severe Left Ventricular Dysfunction.

    Science.gov (United States)

    Kim, Tae Hoon; Shin, Yu Rim; Kim, Young Sam; Kim, Do Jung; Kim, Hyohyun; Shin, Hong Ju; Htut, Aung Thein; Park, Han Ki

    2015-12-01

    A two-month-old infant presented with coarctation of the aorta, severe left ventricular dysfunction, and moderate to severe mitral regurgitation. Through median sternotomy, the aortic arch was repaired under cardiopulmonary bypass and regional cerebral perfusion. The patient was postoperatively supported with a left ventricular assist device for five days. Left ventricular function gradually improved, eventually recovering with the concomitant regression of mitral regurgitation. Prompt surgical repair of coarctation of the aorta is indicated for patients with severe left ventricular dysfunction. A central approach for surgical repair with a back-up left ventricular assist device is a safe and effective treatment strategy for these patients.

  4. Assessing the Nontechnical Skills of Surgical Trainees: Views of the Theater Team.

    Science.gov (United States)

    Al-Jundi, Wissam; Wild, Jonathan; Ritchie, Judith; Daniels, Sarah; Robertson, Eleanor; Beard, Jonathan

    2016-01-01

    This study aims to explore the views of members of theater teams regarding the proposed introduction of a workplace-based assessment of nontechnical skills of surgeons (NOTSS) into the Intercollegiate Surgical Curriculum Programme in the United Kingdom. In addition, the previous training and familiarity of the members of the surgical theater team with the concept and assessment of NOTSS would be evaluated. A regional survey of members of theater teams (consultant surgeons, anesthetists, scrub nurses, and trainees) was performed at 1 teaching and 2 district general hospitals in South Yorkshire. There were 160 respondents corresponding to a response rate of 81%. The majority (77%) were not aware of the NOTSS assessment tool with only 9% of respondents reporting to have previously used the NOTSS tool and just 3% having received training in NOTSS assessment. Overall, 81% stated that assessing NOTSS was as important as assessing technical skills. Trainees attributed less importance to nontechnical skills than the other groups (p ≤ 0.016). Although opinion appears divided as to whether the presence of a consultant surgeon in theater could potentially make it difficult to assess a trainee's leadership skills and decision-making capabilities, overall 60% agree that the routine use of NOTSS assessment would enhance safety in the operating theater and 80% agree that the NOTSS tool should be introduced to assess the nontechnical skills of trainees in theater. However, a significantly lower proportion of trainees (45%) agreed on the latter compared with the other groups (p = 0.001). Our survey demonstrates acceptability among the theater team for the introduction of the NOTSS tool into the surgical curriculum. However, lack of familiarity highlights the importance of faculty training for assessors before such an introduction. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  5. Cognitive and Technical Skill Assessment in Surgical Education: a Changing Horizon.

    Science.gov (United States)

    Vergis, Ashley; Hardy, Krista

    2017-04-01

    Assessment is an integral component of training and credentialing surgeons for practice. Traditional methods of cognitive and technical appraisal are well established but have clear shortcomings. This review outlines the components of the surgical care assessment model, identifies the deficits of current evaluation techniques, and discusses novel and emerging technologies that attempt to ameliorate this educational void.

  6. Getting lost in translation? Workplace based assessments in surgical training.

    Science.gov (United States)

    Ali, Jason M

    2013-10-01

    Workplace based assessments (WBA) are integral to the competence-based surgical training curriculum that currently exists in the UK. The GMC emphasise the value of WBA's as assessments for learning (formative), rather than as assessments of learning (summative). Current implementation of WBA's in the workplace though, is at odds with their intended use, with the formative functions often being overlooked in favour of the summative, as exemplified by the recent announcement that trainees are required to complete a minimum of 40 WBA's a year, an increase from 24. Even before this increase, trainees viewed WBA's as tick-box exercises that negatively impact upon training opportunities. As a result, the tools are commonly misused, often because both trainees and trainers lack understanding of the benefits of full engagement with the formative learning opportunities afforded by WBA's. To aid the transition in mind-set of trainees and trainers to the purpose of assessment in the workplace, the GMC propose the introduction of 'supervised learning events' and 'assessments of performance' to supersede 'WBA's'. The impact of this change and how these will be integrated into surgical training is yet to be seen, but is likely to be a step in the right direction. Copyright © 2013 Royal College of Surgeons of Edinburgh (Scottish charity number SC005317) and Royal College of Surgeons in Ireland. Published by Elsevier Ltd. All rights reserved.

  7. Which hemostatic device in thyroid surgery? A network meta-analysis of surgical technologies.

    Science.gov (United States)

    Garas, George; Okabayashi, Koji; Ashrafian, Hutan; Shetty, Kunal; Palazzo, Fausto; Tolley, Neil; Darzi, Ara; Athanasiou, Thanos; Zacharakis, Emmanouil

    2013-09-01

    Energy-based hemostatic devices are increasingly being used in thyroid surgery. However, there are several limitations with regard to the existing evidence and a paucity of guidelines on the subject. The goal of this review is to employ the novel evidence synthesis technique of a network meta-analysis to assess the comparative effectiveness of surgical technologies in thyroid surgery and contribute to enhanced governance in the field of thyroid surgery. Articles published between January 2000 and June 2012 were identified from Embase, Medline, Cochrane Library, and PubMed databases. Randomized controlled trials of any size comparing the use of ultrasonic coagulation (harmonic scalpel) or Ligasure either head-to-head or against the "clamp-and-tie" technique were included. Two reviewers independently critically appraised and extracted the data from each study. The number of patients who experienced postoperative events was extracted in dichotomous format or continuous outcomes. Odds ratios were calculated by a Bayesian network meta-analysis, and metaregression was used for pair-wise comparisons. Indirect and direct comparisons were performed and inconsistency was assessed. Thirty-five randomized controlled trials with 2856 patients were included. Ultrasonic coagulation ranked first (followed by Ligasure and then clamp-and-tie) with the lowest risk of postoperative hypoparathyroidism (odds ratio 1.43 [95% confidence interval (CI) 0.77-2.67] and 0.70 [CI 0.43-1.13], ultrasonic coagulation vs. Ligasure and ultrasonic coagulation vs. clamp-and-tie, respectively), least blood loss (-0.25 [CI -0.84 to -0.35] and -1.22 [CI -1.85 to -0.59]), and drain output (0.28 [CI -0.35 to -0.91] and -0.36 [CI -0.70 to -0.03]). From a health technology viewpoint, ultrasonic coagulation was associated with the shortest operative time (-0.66 [CI -1.17 to -0.14] and -1.29 [CI -1.59 to -1.00]) and hospital stay (-0.28 [CI -0.78 to 0.22] and -0.56 [CI -1.28 to 0.15]). The only exception

  8. Crowd-sourced assessment of technical skills: an opportunity for improvement in the assessment of laparoscopic surgical skills.

    Science.gov (United States)

    Deal, Shanley B; Lendvay, Thomas S; Haque, Mohamad I; Brand, Timothy; Comstock, Bryan; Warren, Justin; Alseidi, Adnan

    2016-02-01

    Objective, unbiased assessment of surgical skills remains a challenge in surgical education. We sought to evaluate the feasibility and reliability of Crowd-Sourced Assessment of Technical Skills. Seven volunteer general surgery interns were given time for training and then testing, on laparoscopic peg transfer, precision cutting, and intracorporeal knot-tying. Six faculty experts (FEs) and 203 Amazon.com Mechanical Turk crowd workers (CWs) evaluated 21 deidentified video clips using the Global Objective Assessment of Laparoscopic Skills validated rating instrument. Within 19 hours and 15 minutes we received 662 eligible ratings from 203 CWs and 126 ratings from 6 FEs over 10 days. FE video ratings were of borderline internal consistency (Krippendorff's alpha = .55). FE ratings were highly correlated with CW ratings (Pearson's correlation coefficient = .78, P Assessment of Technical Skills as a reliable, basic tool to standardize the evaluation of technical skills in general surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Surgical approach to end-stage heart failure.

    Science.gov (United States)

    Klotz, Stefan; Scheld, Hans H

    2011-02-01

    End-stage heart failure is a challenging disease with growing incidence. With decreasing heart transplant rates worldwide organ preserving therapies become, again, of interest. The purpose of the present review is to examine the potential challenges of surgical therapies in patients with end-stage heart failure. The gold-standard for end-stage heart failure is and will be cardiac transplantation. However, due to organ shortage this therapy is limited to a few patients. Therefore implantation of ventricular assist devices (VADs) or long-term minimal-invasive partial support devices will increase. Improvements in device design with smaller devices, easier implantation techniques, and modified anticoagulation outcome and long-term success will likely improve. In addition, good quality of life as destination therapy is almost available. Organ conservation surgery (coronary artery bypass grafting and surgical ventricular restoration or surgical repair of mitral valve regurgitation) in end-stage heart failure patients could not prove the expected results. Transcatheter or minimal-invasive approaches of these therapies might become routine in the near future. Due to the overwhelming outcome rates, cardiac transplantation is the most established surgical therapy for end-stage heart failure. VAD therapy is increasing and minimized VADs might further open the market for destination therapy/permanent support.

  10. SU-F-T-03: Radiobiological Evaluation of a Directional Brachytherapy Device Surgically Implanted Following EBRT

    Energy Technology Data Exchange (ETDEWEB)

    Rivard, MJ [Tufts University School of Medicine, Boston, MA (United States); Emrich, JG; Poli, J [Drexel University College of Medicine, Philadelphia, PA (United States)

    2016-06-15

    Purpose: Preceding surgical implantation following external-beam radiotherapy (EBRT) delivery, a radiobiological evaluation was performed for a new LDR Pd-103 directional brachytherapy device (CivaSheet). As this was the first case with the device used in combination with EBRT, there was concern to determine the appropriate prescription dose. Methods: The radiobiological model of Dale (1985, 1989) was used for a permanent LDR implant including radioactive decay. The biological effective dose (BED) was converted to the equivalent dose in 2 Gy fractions (EQD2) for comparison with EBRT prescription expectations. Given IMRT delivery of 50.4 Gy, an LDR brachytherapy dose of approximately 15–20 Gy EQD2 was desired. To be specific to the treatment site (leiomyosarcoma T2bN0M0, grade 2 with R1 surgical margin), the radiobiological model required several radiobiological parameters with values taken from the literature. A sensitivity analysis was performed to determine their relative importance on the calculated BED and subsequent EQD2. The Pd-103 decay constant (λ=0.0017 h{sup −1}) was also used. DVHs were prepared for pre- and post-surgical geometries to glean the possible and realized implant geometric configuration. DVHs prepared in VariSeed9 were converted to BEDVHs and subsequently EQD2 values for each volume-element. Results: For a physical dose of 28 Gy to a 0.5 cm depth, BED=21.7 Gy and EQD2=17.6 Gy, which was near the center of the desired EQD2 range. Tumor bed (CTV=4 cm{sup 3}) coverage was 99.2% with 48 sources implanted. In order of decreasing importance from the sensitivity analysis, the radiobiological parameters were α=0.25 Gy{sup −1}, T{sub POT}=23 days, α/β=8.6 Gy, and T=1.5 h. Percentage variations in these values produced EQD2 variations of 40%, 20%, 18%, and 1%, respectively. Conclusion: This radiobiological evaluation indicated that prescription dose may be determined for comparison with the desired EQD2, and that radiobiologicalparameter

  11. Performance Assessment of Communication Enhancement Devices TEA HI Threat Headset

    Science.gov (United States)

    2015-08-01

    AFRL-RH-WP-TR-2015-0076 Performance Assessment of Communication Enhancement Devices: TEA HI Threat Headset Hilary L. Gallagher...of Communication Enhancement Devices: TEA HI Threat Headset 5a. CONTRACT NUMBER FA8650-14-D-6501 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER...technology in military applications. Objective performance data provided an assessment of the performance of these devices. The TEA HI Threat headset

  12. Surgical treatment of lumbar spinal stenosis with microdecompression and interspinous distraction device insertion. A case series

    Directory of Open Access Journals (Sweden)

    Ploumis Avraam

    2012-10-01

    Full Text Available Abstract Background Interspinous distraction devices (IPDD are indicated as stand-alone devices for the treatment of spinal stenosis. The purpose of this study is to evaluate the results of patients undergoing surgery for spinal stenosis with a combination of unilateral microdecompression and interspinous distraction device insertion. Methods This is a prospective clinical and radiological study of minimum 2 years follow-up. Twenty-two patients (average age 64.5 years with low-back pain and unilateral sciatica underwent decompressive surgery for lumbar spinal stenosis. Visual Analogue Scale, Oswestry Disability Index and walking capacity plus radiologic measurements of posterior disc height of the involved level and lumbar lordosis Cobb angle were documented both preoperatively and postoperatively. One-sided posterior subarticular and foraminal decompression was conducted followed by dynamic stabilization of the diseased level with an IPDD (X-STOP. Results The average follow-up time was 27.4 months. Visual Analogue Scale and Oswestry Disability Index improved statistically significantly (p Conclusions The described surgical technique using unilateral microdecompression and IPDD insertion is a clinically effective and radiologically viable treatment method for symptoms of spinal stenosis resistant to non-operative treatment.

  13. Biomechanical evaluation of the X-Stop device for surgical treatment of lumbar spinal stenosis.

    Science.gov (United States)

    Wan, Zongmiao; Wang, Shaobai; Kozánek, Michal; Passias, Peter G; Mansfield, Frederick L; Wood, Kirkham B; Li, Guoan

    2012-10-01

    Controlled experimental study. To evaluate the kinematical effects of X-Stop device on the spinal process at the operated and the adjacent segments before and after X-Stop surgeries during various weight-bearing postures in elderly patients with lumbar spine stenosis. The mechanism of interspinous process (ISP) devices is to directly distract the ISP of the implanted level to indirectly decompress the intervertebra foramen and spinal canal. Few studies have investigated the changes of ISP gap caused by X-Stop implantation using magnetic resonance imaging or radiography, but the effect of X-Stop surgery on the kinematics of spinous processes during functional activities is still unclear. Eight patients were tested before and, on average, 7 months after surgical implantation of the X-Stop devices using a combined computed tomography/magnetic resonance imaging and dual fluoroscopic imaging system during weight-bearing standing, flexion-extension, left-right bending, and left-right twisting positions of the torso. The shortest distances of the ISPs at the operated and the adjacent levels were measured using iterative closest point method and was dissected into vertical (gap) and horizontal (lateral translation) components. At the operated levels, the shortest vertical ISP distances (gap) significantly (P0.05) in right twist, left bend, and right bend after the X-Stop implantation. The lateral translations were not significantly affected. At both cephalad and caudad adjacent levels, the ISP distances (vertical and horizontal) were not significantly affected during all postures after X-Stop implantation. The findings of this study indicate that implantation of the X-Stop devices can effectively distract the ISP space at the diseased level without causing apparent kinematic changes at the adjacent segments during the studied postures.

  14. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  15. Surgical competence.

    Science.gov (United States)

    Patil, Nivritti G; Cheng, Stephen W K; Wong, John

    2003-08-01

    Recent high-profile cases have heightened the need for a formal structure to monitor achievement and maintenance of surgical competence. Logbooks, morbidity and mortality meetings, videos and direct observation of operations using a checklist, motion analysis devices, and virtual reality simulators are effective tools for teaching and evaluating surgical skills. As the operating theater is also a place for training, there must be protocols and guidelines, including mandatory standards for supervision, to ensure that patient care is not compromised. Patients appreciate frank communication and honesty from surgeons regarding their expertise and level of competence. To ensure that surgical competence is maintained and keeps pace with technologic advances, professional registration bodies have been promoting programs for recertification. They evaluate performance in practice, professional standing, and commitment to ongoing education.

  16. Surgical treatment of parastomal hernia

    International Nuclear Information System (INIS)

    Basti, Z.; Mayer, A.

    2013-01-01

    Stoma construction is among standard surgical skills and is performed for many indications. Every stoma means huge impact on quality of life for patients even with great improvement in surgical technique and ostomy devices. All patients are very sensitive to complication of stoma and the most frequent complication is parastomal hernia. Incidence reported in literature is very high and unacceptable, it is 30-70%. Surgical approach is very demanding on technical equipment and experiences of surgeon. Authors focus on each surgical approach for treating this complication weather it´s using mesh or laparoscopic or open approach. (author)

  17. Assessing Residents' Readiness for OR Autonomy: A Qualitative Descriptive Study of Expert Surgical Teachers' Best Practices.

    Science.gov (United States)

    Chen, Xiaodong Phoenix; Sullivan, Amy M; Alseidi, Adnan; Kwakye, Gifty; Smink, Douglas S

    Providing resident autonomy in the operating room (OR) is one of the major challenges for surgical educators today. The purpose of this study was to explore what approaches expert surgical teachers use to assess residents' readiness for autonomy in the OR. We particularly focused on the assessments that experts make prior to conducting the surgical time-out. We conducted semistructured in-depth interviews with expert surgical teachers from March 2016 to September 2016. Purposeful sampling and snowball sampling were applied to identify and recruit expert surgical teachers from general surgery residency programs across the United States to represent a range of clinical subspecialties. All interviews were audio-recorded, deidentified, and transcribed. We applied the Framework Method of content analysis, discussed and reached final consensus on the themes. We interviewed 15 expert teachers from 9 institutions. The majority (13/15) were Program or Associate Program Directors; 47% (7/15) primarily performed complex surgical operations (e.g., endocrine surgery). Five themes regarding how expert surgical teachers determine residents' readiness for OR autonomy before the surgical time-out emerged. These included 3 domains of evidence elicited about the resident (resident characteristics, medical knowledge, and beyond the current OR case), 1 variable relating to attending characteristics, and 1 variable composed of contextual factors. Experts obtained one or more examples of evidence, and adjusted residents' initial autonomy using factors from the attending variable and the context variable. Expert surgical teachers' assessments of residents' readiness for OR autonomy included 5 key components. Better understanding these inputs can contribute to both faculty and resident development, enabling increased resident autonomy and preparation for independent practice. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  18. Factors associated with simulator-assessed laparoscopic surgical skills of veterinary students.

    Science.gov (United States)

    Kilkenny, Jessica J; Singh, Ameet; Kerr, Carolyn L; Khosa, Deep K; Fransson, Boel A

    2017-06-01

    OBJECTIVE To determine whether simulator-assessed laparoscopic skills of veterinary students were associated with training level and prior experience performing nonlaparoscopic veterinary surgery and other activities requiring hand-eye coordination and manual dexterity. DESIGN Experiment. SAMPLE 145 students without any prior laparoscopic surgical or fundamentals of laparoscopic surgery (FLS) simulator experience in years 1 (n = 39), 2 (34), 3 (39), and 4 (33) at a veterinary college. PROCEDURES A questionnaire was used to collect data from participants regarding experience performing veterinary surgery, playing video games, and participating in other activities. Participants performed a peg transfer, pattern cutting, and ligature loop-placement task on an FLS simulator, and FLS scores were assigned by an observer. Scores were compared among academic years, and correlations between amounts of veterinary surgical experience and FLS scores were assessed. A general linear model was used to identify predictors of FLS scores. RESULTS Participants were predominantly female (75%), right-hand dominant (92%), and between 20 and 29 years of age (98%). No significant differences were identified among academic years in FLS scores for individual tasks or total FLS score. Scores were not significantly associated with prior surgical or video game experience. Participants reporting no handicraft experience had significantly lower total FLS scores and FLS scores for task 2 than did participants reporting a lot of handicraft experience. CONCLUSIONS AND CLINICAL RELEVANCE Prior veterinary surgical and video game experience had no influence on FLS scores in this group of veterinary students, suggesting that proficiency of veterinary students in FLS may require specific training.

  19. A Consortium Approach to Surgical Education in a Developing Country: Educational Needs Assessment.

    Science.gov (United States)

    Cook, Mackenzie; Howard, Benjamin M; Yu, Angela; Grey, Douglas; Hofmann, Paul B; Moren, Alexis M; Mchembe, Mabula; Essajee, Abbas; Mndeme, Omari; Peck, James; Schecter, William P

    2015-11-01

    Surgical disease is a global health priority, and improving surgical care requires local capacity building. Single-institution partnerships and surgical missions are logistically limited. The Alliance for Global Clinical Training (hereafter the Alliance) is a consortium of US surgical departments that aims to provide continuous educational support at the Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania (MUHAS). To our knowledge, the Alliance is the first multi-institutional international surgical collaboration to be described in the literature. To assess if the Alliance is effectively responding to the educational needs of MUHAS and Muhimbili National Hospital surgeons. During an initial 13-month program (July 1, 2013, to August 31, 2014), faculty and resident teams from 3 US academic surgical programs rotated at MUHAS as physicians and teachers for 1 month each. To assess the value of the project, we administered anonymous surveys. Anonymous surveys were analyzed on a 5-point Likert-type scale. Free-text answers were analyzed for common themes. During the study period, Alliance members were present at MUHAS for 8 months (1 month each). At the conclusion of the first year of collaboration, 15 MUHAS faculty and 22 MUHAS residents completed the survey. The following 6 areas of educational needs were identified: formal didactics, increased clinical mentorship, longer-term Alliance presence, equitable distribution of teaching time, improved coordination and language skills, and reciprocal exchange rotations at US hospitals. The MUHAS faculty and residents agreed that Alliance members contributed to improved patient care and resident education. A multi-institutional international surgical partnership is possible and leads to perceived improvements in patient care and resident learning. Alliance surgeons must continue to focus on training Tanzanian surgeons. Improving the volunteer surgeons' Swahili-language skills would be an asset. Future

  20. Assessment of Periodontal Status of Surgically Exposed and Orthodontically Aligned Impacted Maxillary Canines

    Directory of Open Access Journals (Sweden)

    Adina Coșarcă

    2014-02-01

    Full Text Available Aim: The aim of this study was to compare the periodontal status of impacted canines after 5 years following completion of the combined surgical and orthodontic treatment. Materials and methods: We examined 20 labially impacted canines and 20 palatally impacted canines at 5 years after the end of treatment. We assessed the periodontal status of these teeth. Results: Different outcomes were found regarding the probing depth and the amount of keratinized gingiva in the two mentioned groups of teeth. Conclusions: The assessed periodontal indices may signal the appearance of a periodontal disease around the teeth that were surgically and orthodontically treated

  1. Translation and validation of the assistive technology device predisposition assessment in Greek in order to assess satisfaction with use of the selected assistive device.

    Science.gov (United States)

    Koumpouros, Yiannis; Papageorgiou, Effie; Karavasili, Alexandra; Alexopoulou, Despoina

    2017-07-01

    To examine the Assistive Technology Device Predisposition Assessment scale and provide evidence of validity and reliability of the Greek version. We translated and adapted the original instrument in Greek according to the most well-known guidelines recommendations. Field test studies were conducted in a rehabilitation hospital to validate the appropriateness of the final results. Ratings of the different items were statistically analyzed. We recruited 115 subjects who were administered the Form E of the original questionnaire. The experimental analysis conducted revealed a three subscales structure: (i) Adaptability, (ii) Fit to Use, and (iii) Socializing. According to the results of our study the three subscales measure different constructs. Reliability measures (ICC = 0.981, Pearson's correlation = 0.963, Cronbach's α = 0.701) yielded high values. Test-retest outcome showed great stability. This is the first study, at least to the knowledge of the authors, which focuses merely on measuring the satisfaction of the users from the used assistive device, while exploring the Assistive Technology Device Predisposition Assessment - Device Form in such depth. According to the results, it is a stable, valid and reliable instrument and applicable to the Greek population. Thus, it can be used to measure the satisfaction of patients with assistive devices. Implications for Rehabilitation The paper explores the cultural adaptability and applicability of ATD PA - Device Form. ATD PA - Device Form can be used to assess user satisfaction by the selected assistive device. ATD PA - Device Form is a valid and reliable instrument in measuring users' satisfaction in Greekreality.

  2. Comparison between transcatheter and surgical closure of secundum atrial septal defect in patients over 40 years old

    International Nuclear Information System (INIS)

    Wang Cheng; Zhao Shihua; Jiang Shiliang; Huang Lianjun; Xu Zhongying; Ling Jian; Zheng Hong; Zhang Gejun; Lv Bin; Zhang Yan; Jin Jinglin; Yan Chaowu; Dai Ruping

    2007-01-01

    Objective: To compare the safety and efficacy of transcatheter closure of secundum atrial septal defect (ASD) with surgical closure in patients over 40 years old. Methods: A single center, nonrandomized concurrent study was performed in 233 consecutive adults from January, 2004 to December, 2005. The patients were assigned to either the device or surgical closure group according to the patients options. Technical success rate, complications, residual shunt, hospital stay, amount of blood transfusion and cost were compared. Results: A total of 137 patients were in the group undergoing device closure, whereas 96 patients were in the surgical group. There was no differences in age, sex distribution or baseline cardiac function between the two groups. The sizes of the ASD were(18.9±5.4) mm for the device group and (24.9 ± 6.8)mm for the surgical group (P<0.001). The technical success rates were 97.1% for the device group and 100% for the surgical group (P=0.151). The residual shunt rates were 0.7% for the device group and 0% for the surgical group (P=0.583). Mortality was zero for both groups. The complication rates were 16.1% for the device group and 30.2% for the surgical group (P=0.015). The blood transfusion amounts were (273.1 ± 491.5)ml for the surgical group and 0 ml for the device group (P<0.001). The lengths of hospital stay were (4.6 ± 3.3)days for the device group and (12.0 ± 4.0) days for the surgical group (P<0.001). The costs of hospital stay were 39 570.0±5 929.5 RMB for the device group and 29 839.6±7 533.1 RMB for the surgical group (p<0.001). Conclusions: The technical success rates for surgical versus device closure of ASD were of significantly different, however, the complication rate was lower and the length of hospital stay was shorter for device closure than those for surgical repair. Transcatheter closure of secundum ASD is a safe and effective alternative to surgical repair in selected patients. (authors)

  3. A projective surgical navigation system for cancer resection

    Science.gov (United States)

    Gan, Qi; Shao, Pengfei; Wang, Dong; Ye, Jian; Zhang, Zeshu; Wang, Xinrui; Xu, Ronald

    2016-03-01

    Near infrared (NIR) fluorescence imaging technique can provide precise and real-time information about tumor location during a cancer resection surgery. However, many intraoperative fluorescence imaging systems are based on wearable devices or stand-alone displays, leading to distraction of the surgeons and suboptimal outcome. To overcome these limitations, we design a projective fluorescence imaging system for surgical navigation. The system consists of a LED excitation light source, a monochromatic CCD camera, a host computer, a mini projector and a CMOS camera. A software program is written by C++ to call OpenCV functions for calibrating and correcting fluorescence images captured by the CCD camera upon excitation illumination of the LED source. The images are projected back to the surgical field by the mini projector. Imaging performance of this projective navigation system is characterized in a tumor simulating phantom. Image-guided surgical resection is demonstrated in an ex-vivo chicken tissue model. In all the experiments, the projected images by the projector match well with the locations of fluorescence emission. Our experimental results indicate that the proposed projective navigation system can be a powerful tool for pre-operative surgical planning, intraoperative surgical guidance, and postoperative assessment of surgical outcome. We have integrated the optoelectronic elements into a compact and miniaturized system in preparation for further clinical validation.

  4. Identifying optimal postmarket surveillance strategies for medical and surgical devices: implications for policy, practice and research.

    Science.gov (United States)

    Gagliardi, Anna R; Umoquit, Muriah; Lehoux, Pascale; Ross, Sue; Ducey, Ariel; Urbach, David R

    2013-03-01

    Non-drug technologies offer many benefits, but have been associated with adverse events, prompting calls for improved postmarket surveillance. There is little empirical research to guide the development of such a system. The purpose of this study was to identify optimal postmarket surveillance strategies for medical and surgical devices. Qualitative methods were used for sampling, data collection and analysis. Stakeholders from Canada and the USA representing different roles and perspectives were first interviewed to identify examples and characteristics of different surveillance strategies. These stakeholders and others they recommended were then assembled at a 1-day nominal group meeting to discuss and prioritise the components of a postmarket device surveillance system, and research needed to achieve such a system. Consultations were held with 37 participants, and 47 participants attended the 1-day meeting. They recommended a multicomponent system including reporting by facilities, clinicians and patients, supported with some external surveillance for validation and real-time trials for high-risk devices. Many considerations were identified that constitute desirable characteristics of, and means by which to implement such a system. An overarching network was envisioned to broker linkages, establish a shared minimum dataset, and support communication and decision making. Numerous research questions were identified, which could be pursued in tandem with phased implementation of the system. These findings provide unique guidance for establishing a device safety network that is based on existing initiatives, and could be expanded and evaluated in a prospective, phased fashion as it was developed.

  5. A Descriptive Analysis of the Use of Workplace-Based Assessments in UK Surgical Training.

    Science.gov (United States)

    Shalhoub, Joseph; Santos, Cristel; Bussey, Maria; Eardley, Ian; Allum, William

    2015-01-01

    Workplace-based assessments (WBAs) were introduced formally in the UK in 2007. The aim of the study was to describe the use of WBAs by UK surgical trainees and examine variations by training region, specialty, and level of training. The database of the Intercollegiate Surgical Curriculum Programme was examined for WBAs between August 2007 and July 2013, with in-depth analysis of 2 periods: August 2011 to July 2012 and August 2012 to July 2013. The numbers of validated WBAs per trainee per year increased more than 7-fold, from median 6 per trainee in 2007 to 2008, to 39 in 2011 to 2012, and 44 in 2012 to 2013. In the period 2011 to 2012, 58.4% of core trainees completed the recommended 40 WBAs, with only 38.1% of specialty trainees achieving 40 validated WBAs. In the period 2012 to 2013, these proportions increased to 67.7% and 57.0% for core and specialty trainees, respectively. Core trainees completed more WBAs per year than specialty trainees in the same training region. London core trainees completed the highest numbers of WBAs in both the periods 2011 to 2012 (median 67) and 2012 to 2013 (median 74). There was a peak in WBAs completed by London specialty trainees in the period 2012 to 2013 (median 63). The most validated WBAs were completed by ST1/CT1 (specialty surgical training year, core surgical training year), with a gradual decrease in median WBAs to ST4, followed by a plateau; in the period 2012 to 2013, there was an increase in WBAs at ST8. Core surgical trainees complete ~50% "operative" (procedure-based assessment/direct observation of procedural skills) and ~50% "nonoperative" assessments (case-based discussion/clinical evaluation exercise). During specialty training, procedure-based assessments represented ~46% of WBAs, direct observation of procedural skills 11.2%, case-based discussion ~23%, and clinical evaluation exercise ~15%. UK surgical trainees are, on an average, undertaking 1 WBA per week. Variation exists in use of WBAs between training

  6. The application of wearable technology in surgery: ensuring the positive impact of the wearable revolution on surgical patients.

    Science.gov (United States)

    Slade Shantz, Jesse Alan; Veillette, Christian J H

    2014-01-01

    Wearable technology has become an important trend in consumer electronics in the past year. The miniaturization and mass production of myriad sensors have made possible the integration of sensors and output devices in wearable platforms. Despite the consumer focus of the wearable revolution some surgical applications are being developed. These fall into augmentative, assistive, and assessment functions and primarily layer onto current surgical workflows. Some challenges to the adoption of wearable technologies are discussed and a conceptual framework for understanding the potential of wearable technology to revolutionize surgical practice are presented.

  7. A randomized trial of standardized nursing patient assessment using wireless devices.

    Science.gov (United States)

    Dykes, Patricia C; Carroll, Diane L; Benoit, Angela; Coakley, Amanda; Chang, Frank; Empoliti, Joanne; Gallagher, Joan; Lasala, Cynthia; O'Malley, Rosemary; Rath, Greg; Silva, Judy; Li, Qi

    2007-10-11

    A complete and accurate patient assessment database is essential for effective communication, problem identification, planning and evaluation of patient status. When employed consistently for point-of-care documentation, information systems are associated with completeness and quality of documentation. The purpose of this paper is to report on the findings of a randomized, cross-over study conducted to evaluate the adequacy of a standard patient assessment module to support problem identification, care planning and tracking of nursing sensitive patient outcomes. The feasibility of wireless devices to support patient assessment data collection at the point-of-care was evaluated using wireless PDAs and tablet PCs. Seventy-nine (79) nurses from two patient care units at Massachusetts General Hospital (Boston, MA) were recruited into the study and randomized to complete patient assessment using wireless or paper devices. At the end of six weeks, nurses who where randomized to the paper assessment module were assigned to a device and those who used a device were assigned to paper for an additional six weeks. Impact was evaluated with regard to data capture, workflow implications and nurse satisfaction. Findings suggest that a standard patient assessment set promotes patient sensitive and quality data capture, which is augmented by the use of wireless devices.

  8. Economic evaluations of comprehensive geriatric assessment in surgical patients: a systematic review.

    Science.gov (United States)

    Eamer, Gilgamesh; Saravana-Bawan, Bianka; van der Westhuizen, Brenden; Chambers, Thane; Ohinmaa, Arto; Khadaroo, Rachel G

    2017-10-01

    Seniors presenting with surgical disease face increased risk of postoperative morbidity and mortality and have increased treatment costs. Comprehensive Geriatric Assessment (CGA) is proposed to reduce morbidity, mortality, and the cost after surgery. A systematic review of CGA in emergency surgical patients was conducted. The primary outcome was cost-effectiveness; secondary outcomes were length of stay, return of function, and mortality. Inclusion and exclusion criteria were predefined. Systematic searches of MEDLINE, Embase, Cochrane, and National Health Service Economic Evaluation Database were performed. Text screening, bias assessment, and data extraction were performed by two authors. There were 560 articles identified; abstract review excluded 499 articles and full-text review excluded 53 articles. Eight studies were included; one nonorthopedic trauma and seven orthopedic trauma studies. Bias assessment revealed moderate to high risk of bias for all studies. Economic evaluation assessment identified two high-quality studies and six moderate or low quality studies. Pooled analysis from four studies assessed loss of function; loss of function decreased in the experimental arm (odds ratio 0.92, 95% confidence interval [CI]: 0.88-0.97). Pooled results for length of stay from five studies found a significant decrease (mean difference: -1.17, 95% CI: -1.63 to -0.71) after excluding the nonorthopedic trauma study. Pooled mortality was significantly decreased in seven studies (risk ratio: 0.78, 95% CI: 0.67-0.90). All studies decreased cost and improved health outcomes in a cost-effective manner. CGA improved return of function and mortality with reduced cost or improved utility. Our review suggests that CGA is economically dominant and the most cost-effective care model for orthogeriatric patients. Further research should examine other surgical fields. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Radioactive tracers in the assessment of cleaning of surgical appliances

    International Nuclear Information System (INIS)

    Mostafa, A.B.M.G.; Chackett, K.F.

    1975-01-01

    Radioactive tracers which may be used in the assessment of cleaning of surgical appliances are described. Five labelled compounds were used as soiling material and tested in the rather severe conditions that exist during cleaning cycles. Measurements of decontamination in two cases were considered reliable but in the other three some degree of decomposition of the soil occurred, which falsified the results. (author)

  10. Assessment of CANDU-6 reactivity devices for DUPIC fuel

    International Nuclear Information System (INIS)

    Jeong, Chang Joon; Choi, Hang Bok

    1998-11-01

    Reactivity device characteristics for a CANDU 6 reactor loaded with DUPIC fuel have been assessed. The lattice parameters were generated by WIMS-AECL code and the core calculations were performed by RFSP code with a 3-dimensional full core model. The reactivity devices studied are the zone controller, adjusters, mechanical control absorber and shutoff rods. For the zone controller system, damping capability for spatial oscillation was investigated. For the adjusters, the restart capability was investigated. For the adjusters, the restart capability was investigated. The shin operation and power stepback calculation were also performed to confirm the compatibility of the current adjuster system. The mechanical control absorber was assessed for the function of compensating temperature reactivity feedback following a power reduction. And shutoff rods were also assessed to investigate the following a power reduction. And shutoff rods were also assessed to investigate the static reactivity worth. This study has shown that the current reactivity device system of CANDU-6 core with the DUPIC fuel. (author). 9 refs., 17 tabs., 7 figs

  11. Contemporary surgical devices for male stress urinary incontinence: a review of technological advances in current continence surgery.

    Science.gov (United States)

    Chung, Eric

    2017-07-01

    Male stress urinary incontinence (SUI) remains a debilitating condition that adversely impacts all domains of quality of life and is associated with significant social stigma and health economic burden. The incidence of post-prostatectomy urinary incontinence (PPI) depends on the definition of urinary incontinence and the length of patient follow up. In patients with persistent PPI following failure of conservative measures, surgical treatment is recommended although there is no published guideline on when surgery should be performed, and what the best surgical option is. Male slings (MS) can be divided into adjustable or non-adjustable types, and offers an attractive option for patients who wish to avoid mechanical handling during urinary voiding. Published intermediate data supports good safety and efficacy rate in men with mild to moderate degree of SUI. The AMS 800 artificial urinary sphincter (AUS) remains the standard of treatment for complete continence and has the longest efficacy and safety records. Other AUS-like devices are designed to address current AMS 800 limitations but themselves are fraught with their own issues.

  12. Pictorial Review of Surgical Anatomy in Adult Congenital Heart Disease.

    Science.gov (United States)

    De Cecco, Carlo N; Muscogiuri, Giuseppe; Madrid Pérez, José M; Eid, Marwen; Suranyi, Pal; Lesslie, Virginia W; Bastarrika, Gorka

    2017-07-01

    The survival rate of patients with congenital heart disease (CHD) has dramatically improved over the last 2 decades because of technological and surgical advances in diagnosis and treatment, respectively. The vast majority of CHD patients are, in fact, amenable to treatment by either device closure or surgery. Considering the wide spectrum of surgical procedures and complex native and derived anatomy, continuous and detailed follow-up is of paramount importance. Cardiac magnetic resonance and cardiac computed tomography angiography are the cornerstones of diagnosis and follow-up of CHD, allowing for comprehensive noninvasive assessment of the heart, coronary tree, and intrathoracic great vessels, along with both morphological and functional evaluation. The aim of this pictorial review is to provide an overview of the most common CHDs and their related surgical procedures as familiarity with the radiological findings of grown-up congenital heart disease patients is crucial for proper diagnostic and follow-up pathways.

  13. Application of Devices and Systems Designed for Power Quality Monitoring and Assessment

    Directory of Open Access Journals (Sweden)

    Wiesław Gil

    2014-03-01

    Full Text Available The paper presents the problems associated with increasing demands on the equipment and systems for power quality assessment (PQ, installed at power substations. Difficulties are signaled due to current lack of standards defining the test methodology of measuring devices. The necessary device properties and the structure of a large system operated in real time and designed to assess the PQ are discussed. The usefulness of multi-channel analyzers featuring the identification and registration of transients is pointed out. The desirability of synchrophasor assessment implementation and device integration by standard PN-EN 61850 with other SAS devices is also justified.

  14. Challenges to the development of complex virtual reality surgical simulations.

    Science.gov (United States)

    Seymour, N E; Røtnes, J S

    2006-11-01

    Virtual reality simulation in surgical training has become more widely used and intensely investigated in an effort to develop safer, more efficient, measurable training processes. The development of virtual reality simulation of surgical procedures has begun, but well-described technical obstacles must be overcome to permit varied training in a clinically realistic computer-generated environment. These challenges include development of realistic surgical interfaces and physical objects within the computer-generated environment, modeling of realistic interactions between objects, rendering of the surgical field, and development of signal processing for complex events associated with surgery. Of these, the realistic modeling of tissue objects that are fully responsive to surgical manipulations is the most challenging. Threats to early success include relatively limited resources for development and procurement, as well as smaller potential for return on investment than in other simulation industries that face similar problems. Despite these difficulties, steady progress continues to be made in these areas. If executed properly, virtual reality offers inherent advantages over other training systems in creating a realistic surgical environment and facilitating measurement of surgeon performance. Once developed, complex new virtual reality training devices must be validated for their usefulness in formative training and assessment of skill to be established.

  15. Predictive Factors for Patients Undergoing ASD Device Occlusion Who "Crossover" to Surgery.

    Science.gov (United States)

    Mulukutla, Venkatachalam; Qureshi, Athar M; Pignatelli, Ricardo; Ing, Frank F

    2018-03-01

    The aim of this study was to define characteristics of those patients who are referred for device closure of an Atrial septal defect (ASD), but identified to "crossover" surgery. All patients who underwent surgical and device (Amplatzer or Helex occluder) closures of secundum ASDs from 2001 to 2010 were reviewed and organized into three groups: surgical closure, device closure, and "crossover" group. 369 patients underwent ASD closure (265 device, 104 surgical). 42 of the 265 patients referred for device closure "crossed over" to the surgical group at various stages of the catheterization procedure. The device group had defect size measuring 14.2 mm (mean) and an ASD index (Defect Size (mm)/BSA) of 14.0 compared to the corresponding values in the surgical group (20.1 mm, ASD index 25.9) (P ASD index) (P ASD index of 14.7 compared with the crossover group ASD index of 23.8 (P ASD index greater than 23.7 had a 90% specificity in "crossing over" to surgery. The crossover and surgical groups had statistically larger ASD defect size indexes compared with the device group. Deficient rim in the posterior/inferior rim is associated with a large ASD size index which is a predictive factor for crossing over to surgery. Catheterization did not negatively impact surgical results in the "crossover" group.

  16. Assessment of reactivity devices for CANDU-6 with DUPIC fuel

    International Nuclear Information System (INIS)

    Jeong, Chang Joon; Choi, Hang Bok

    1998-01-01

    Reactivity device characteristics for a CANDU-6 reactor loaded with DUPIC fuel have been assessed. A transport code WIMS-AECL and a three-dimensional diffusion code RFSP were used for the lattice parameter generation and the core calculation, respectively. Three major reactivity devices have been assessed for their inherent functions. For the zone controller system, damping capability for spatial oscillation was investigated. The restart capability of the adjuster system was investigated. The shim operation and power stepback calculation were also performed to confirm the compatibility of the current adjuster rod system. The mechanical control absorber was assessed for the capability to compensate the temperature reactivity feedback following a power reduction. This study has shown that the current reactivity device systems retain their functions when used in a DUPIC fuel CANDU reactor

  17. Assessment of laparoscopic psychomotor skills in interns using the MIST Virtual Reality Simulator: a prerequisite for those considering surgical training?

    Science.gov (United States)

    Cope, Daron H; Fenton-Lee, Douglas

    2008-04-01

    Selection for surgical training in Australia is currently based on assessment of a structured curriculum vitae, referral reports from selected clinicians and an interview. The formal assessment of laparoscopic psychomotor skill and ability to attain skills is not currently a prerequisite for selection. The aim of this study was to assess the innate psychomotor skills of interns and also to compare interns with an interest in pursuing a surgical career to interns with those with no interest in pursuing a surgical career. Twenty-two interns were given the opportunity to carry out tasks on the Minimal Invasive Surgical Trainer, Virtual Reality (Mentice, Gothenburg, Sweden) Simulator. The candidates were required to complete six tasks, repeated six times each. Scores for each task were calculated objectively by the simulator software. Demographic data were similar between the two groups. Although some candidates who were interested in pursuing a surgical career performed poorly on the simulator, there was no significant difference when comparing the two groups. The Minimal Invasive Surgical Trainer, Virtual Reality (Mentice) Simulator provides an objective and comparable assessment of laparoscopic psychomotor skills. We can conclude that interns have varying inherent ability as judged by the simulator and this does not seem to have an influence on their career selection. There was no significant difference in the scores between the two groups. Interns with and without inherent abilities have aspirations to pursue surgical careers and their aptitude does not seem to influence this decision. Surgical colleges could use psychomotor ability assessments to recruit candidates to pursue a career in surgery. Trainees needing closer monitoring and additional training could be identified early and guided to achieve competency.

  18. CT pre-operative planning of a new semi-implantable bone conduction hearing device

    Energy Technology Data Exchange (ETDEWEB)

    Law, Eric K.C.; Bhatia, Kunwar S.S. [Prince of Wales Hospital, The Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Hong Kong, SAR (China); Tsang, Willis S.S.; Tong, Michael C.F. [Prince of Wales Hospital, The Chinese University of Hong Kong, Department of Otorhinolaryngology, Head and Neck Surgery, Hong Kong, SAR (China); Shi, Lin [The Chinese University of Hong Kong, Department of Medicine and Therapeutics, Hong Kong, SAR (China); The Chinese University of Hong Kong, Chow Yuk Ho Technology Center for Innovative Medicine, Hong Kong, SAR (China)

    2016-06-15

    Accommodating a novel semi-implantable bone conduction hearing device within the temporal bone presents challenges for surgical planning. This study describes the utility of CT in pre-operative assessment of such an implant. Retrospective review of pre-operative CT, clinical and surgical records of 16 adults considered for device implantation. Radiological suitability was assessed on CT using 3D simulation software. Antero-posterior (AP) dimensions of the mastoid bone and minimum skull thickness were measured. CT planning results were correlated with operative records. Eight and five candidates were suitable for device placement in the transmastoid and retrosigmoid positions, respectively, and three were radiologically unsuitable. The mean AP diameter of the mastoid cavity was 14.6 mm for the transmastoid group and 4.6 mm for the retrosigmoid group (p < 0.05). Contracted mastoid and/or prior surgery were predisposing factors for unsuitability. Four transmastoid and five retrosigmoid positions required sigmoid sinus/dural depression and/or use of lifts due to insufficient bone capacity. A high proportion of patients being considered have contracted or operated mastoids, which reduces the feasibility of the transmastoid approach. This finding combined with the complex temporal bone geometry illustrates the importance of careful CT evaluation using 3D software for precise device simulation. (orig.)

  19. Registry Assessment of Peripheral Interventional Devices (RAPID): Registry assessment of peripheral interventional devices core data elements.

    Science.gov (United States)

    Jones, W Schuyler; Krucoff, Mitchell W; Morales, Pablo; Wilgus, Rebecca W; Heath, Anne H; Williams, Mary F; Tcheng, James E; Marinac-Dabic, J Danica; Malone, Misti L; Reed, Terrie L; Fukaya, Rie; Lookstein, Robert A; Handa, Nobuhiro; Aronow, Herbert D; Bertges, Daniel J; Jaff, Michael R; Tsai, Thomas T; Smale, Joshua A; Zaugg, Margo J; Thatcher, Robert J; Cronenwett, Jack L

    2018-02-01

    The current state of evaluating patients with peripheral artery disease and more specifically of evaluating medical devices used for peripheral vascular intervention (PVI) remains challenging because of the heterogeneity of the disease process, the multiple physician specialties that perform PVI, the multitude of devices available to treat peripheral artery disease, and the lack of consensus about the best treatment approaches. Because PVI core data elements are not standardized across clinical care, clinical trials, and registries, aggregation of data across different data sources and physician specialties is currently not feasible. Under the auspices of the U.S. Food and Drug Administration's Medical Device Epidemiology Network initiative-and its PASSION (Predictable and Sustainable Implementation of the National Registries) program, in conjunction with other efforts to align clinical data standards-the Registry Assessment of Peripheral Interventional Devices (RAPID) workgroup was convened. RAPID is a collaborative, multidisciplinary effort to develop a consensus lexicon and to promote interoperability across clinical care, clinical trials, and national and international registries of PVI. The current manuscript presents the initial work from RAPID to standardize clinical data elements and definitions, to establish a framework within electronic health records and health information technology procedural reporting systems, and to implement an informatics-based approach to promote the conduct of pragmatic clinical trials and registry efforts in PVI. Ultimately, we hope this work will facilitate and improve device evaluation and surveillance for patients, clinicians, health outcomes researchers, industry, policymakers, and regulators. Copyright © 2017 Society for Vascular Surgery. All rights reserved.

  20. Performance Assessment of Bi-Directional Knotless Tissue-Closure Devices in Juvenile Chinook Salmon Surgically Implanted with Acoustic Transmitters, 2009 - Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Woodley, Christa M.; Wagner, Katie A.; Bryson, Amanda J.

    2012-11-09

    The purpose of this report is to assess the performance of bi-directional knotless tissue-closure devices for use in tagging juvenile salmon. This study is part of an ongoing effort at Pacific Northwest National Laboratory (PNNL) to reduce unwanted effects of tags and tagging procedures on the survival and behavior of juvenile salmonids, by assessing and refining suturing techniques, suture materials, and tag burdens. The objective of this study was to compare the performance of the knotless (barbed) suture, using three different suture patterns (treatments: 6-point, Wide “N”, Wide “N” Knot), to the current method of suturing (MonocrylTM monofilament, discontinuous sutures with a 2×2×2×2 knot) used in monitoring and research programs with a novel antiseptic barrier on the wound (“Second Skin”).

  1. A randomized, controlled, multicenter contraceptive efficacy clinical trial of the intravas device, a nonocclusive surgical male sterilization

    Directory of Open Access Journals (Sweden)

    Wen-Hong Lu

    2014-06-01

    Full Text Available Because of unavoidable complications of vasectomy, this study was undertaken to assess the efficacy and safety of male sterilization with a nonobstructive intravas device (IVD implanted into the vas lumen by a mini-surgical method compared with no-scalpel vasectomy (NSV. IVDs were categorized into two types: IVD-B has a tail used for fixing to the vas deferens (fixed wing whereas IVD-A does not. A multicenter prospective randomized controlled clinical trial was conducted in China. The study was comprised of 1459 male volunteers seeking vasectomy who were randomly assigned to the IVD-A (n = 487, IVD-B (n = 485 or NSV (n = 487 groups and underwent operation. Follow-up included visits at the 3 rd -6 th and 12 th postoperative months. The assessments of the subjects involved regular physical examinations (including general and andrological examinations and semen analysis. The subjects' partners also underwent monitoring for pregnancy by monthly interviews regarding menstruation and if necessary, urine tests. There were no significant differences in pregnancy rates (0.65% for IVD-A, 0 for IVD-B and 0.21% for NSV among the three groups (P > 0.05. The cumulative rates of complications at the 12 th postoperative month were zero, 0.9% and 1.7% in the three groups, respectively. In conclusion, IVD male sterilization exhibits a low risk of long-term adverse events and was found to be effective as a male sterilization method, similar to the NSV technique. IVD male sterilization is expected to be a novel contraceptive method.

  2. A randomized, controlled, multicenter contraceptive efficacy clinical trial of the intravas device, a nonocclusive surgical male sterilization

    Science.gov (United States)

    Lu, Wen-Hong; Liang, Xiao-Wei; Gu, Yi-Qun; Wu, Wei-Xiong; Bo, Li-Wei; Zheng, Tian-Gui; Chen, Zhen-Wen

    2014-01-01

    Because of unavoidable complications of vasectomy, this study was undertaken to assess the efficacy and safety of male sterilization with a nonobstructive intravas device (IVD) implanted into the vas lumen by a mini-surgical method compared with no-scalpel vasectomy (NSV). IVDs were categorized into two types: IVD-B has a tail used for fixing to the vas deferens (fixed wing) whereas IVD-A does not. A multicenter prospective randomized controlled clinical trial was conducted in China. The study was comprised of 1459 male volunteers seeking vasectomy who were randomly assigned to the IVD-A (n = 487), IVD-B (n = 485) or NSV (n = 487) groups and underwent operation. Follow-up included visits at the 3rd–6th and 12th postoperative months. The assessments of the subjects involved regular physical examinations (including general and andrological examinations) and semen analysis. The subjects’ partners also underwent monitoring for pregnancy by monthly interviews regarding menstruation and if necessary, urine tests. There were no significant differences in pregnancy rates (0.65% for IVD-A, 0 for IVD-B and 0.21% for NSV) among the three groups (P > 0.05). The cumulative rates of complications at the 12th postoperative month were zero, 0.9% and 1.7% in the three groups, respectively. In conclusion, IVD male sterilization exhibits a low risk of long-term adverse events and was found to be effective as a male sterilization method, similar to the NSV technique. IVD male sterilization is expected to be a novel contraceptive method. PMID:24589454

  3. Development and validation of surgical training tool: cystectomy assessment and surgical evaluation (CASE) for robot-assisted radical cystectomy for men.

    Science.gov (United States)

    Hussein, Ahmed A; Sexton, Kevin J; May, Paul R; Meng, Maxwell V; Hosseini, Abolfazl; Eun, Daniel D; Daneshmand, Siamak; Bochner, Bernard H; Peabody, James O; Abaza, Ronney; Skinner, Eila C; Hautmann, Richard E; Guru, Khurshid A

    2018-04-13

    We aimed to develop a structured scoring tool: cystectomy assessment and surgical evaluation (CASE) that objectively measures and quantifies performance during robot-assisted radical cystectomy (RARC) for men. A multinational 10-surgeon expert panel collaborated towards development and validation of CASE. The critical steps of RARC in men were deconstructed into nine key domains, each assessed by five anchors. Content validation was done utilizing the Delphi methodology. Each anchor was assessed in terms of context, score concordance, and clarity. The content validity index (CVI) was calculated for each aspect. A CVI ≥ 0.75 represented consensus, and this statement was removed from the next round. This process was repeated until consensus was achieved for all statements. CASE was used to assess de-identified videos of RARC to determine reliability and construct validity. Linearly weighted percent agreement was used to assess inter-rater reliability (IRR). A logit model for odds ratio (OR) was used to assess construct validation. The expert panel reached consensus on CASE after four rounds. The final eight domains of the CASE included: pelvic lymph node dissection, development of the peri-ureteral space, lateral pelvic space, anterior rectal space, control of the vascular pedicle, anterior vesical space, control of the dorsal venous complex, and apical dissection. IRR > 0.6 was achieved for all eight domains. Experts outperformed trainees across all domains. We developed and validated a reliable structured, procedure-specific tool for objective evaluation of surgical performance during RARC. CASE may help differentiate novice from expert performances.

  4. Surgical Vision: Google Glass and Surgery.

    Science.gov (United States)

    Chang, Johnny Yau Cheung; Tsui, Lok Yee; Yeung, Keith Siu Kay; Yip, Stefanie Wai Ying; Leung, Gilberto Ka Kit

    2016-08-01

    Google Glass is, in essence, a smartphone in the form of a pair of spectacles. It has a display system, a bone conduction "speaker," video camera, and connectivity via WiFi or Bluetooth technologies. It can also be controlled by voice command. Seizing Google Glass' capabilities as windows of opportunity, surgeons have been the first group of doctors trying to incorporate the technology into their daily practices. Experiences from different groups have demonstrated Google Glass' potential in improving perioperative care, intraoperative communication and documentation, surgical outcome as well as surgical training. On the other hand, the device has technical limitations, notably suboptimal image qualities and a short battery life. Its operational functions also bring forth concerns on the protection of patient privacy. Nonetheless, the technological advances that this device embodies hold promises in surgical innovations. Further studies are required, and surgeons should explore, investigate, and embrace similar technologies with keen and informed anticipation. © The Author(s) 2016.

  5. Open surgical simulation--a review.

    Science.gov (United States)

    Davies, Jennifer; Khatib, Manaf; Bello, Fernando

    2013-01-01

    Surgical simulation has benefited from a surge in interest over the last decade as a result of the increasing need for a change in the traditional apprentice model of teaching surgery. However, despite the recent interest in surgical simulation as an adjunct to surgical training, most of the literature focuses on laparoscopic, endovascular, and endoscopic surgical simulation with very few studies scrutinizing open surgical simulation and its benefit to surgical trainees. The aim of this review is to summarize the current standard of available open surgical simulators and to review the literature on the benefits of open surgical simulation. Open surgical simulators currently used include live animals, cadavers, bench models, virtual reality, and software-based computer simulators. In the current literature, there are 18 different studies (including 6 randomized controlled trials and 12 cohort studies) investigating the efficacy of open surgical simulation using live animal, bench, and cadaveric models in many surgical specialties including general, cardiac, trauma, vascular, urologic, and gynecologic surgery. The current open surgical simulation studies show, in general, a significant benefit of open surgical simulation in developing the surgical skills of surgical trainees. However, these studies have their limitations including a low number of participants, variable assessment standards, and a focus on short-term results often with no follow-up assessment. The skills needed for open surgical procedures are the essential basis that a surgical trainee needs to grasp before attempting more technical procedures such as laparoscopic procedures. In this current climate of medical practice with reduced hours of surgical exposure for trainees and where the patient's safety and outcome is key, open surgical simulation is a promising adjunct to modern surgical training, filling the void between surgeons being trained in a technique and a surgeon achieving fluency in that

  6. A New Tool for Assessing Mobile Device Proficiency in Older Adults: The Mobile Device Proficiency Questionnaire.

    Science.gov (United States)

    Roque, Nelson A; Boot, Walter R

    2018-02-01

    Mobile device proficiency is increasingly required to participate in society. Unfortunately, there still exists a digital divide between younger and older adults, especially with respect to mobile devices (i.e., tablet computers and smartphones). Training is an important goal to ensure that older adults can reap the benefits of these devices. However, efficient/effective training depends on the ability to gauge current proficiency levels. We developed a new scale to accurately assess the mobile device proficiency of older adults: the Mobile Device Proficiency Questionnaire (MDPQ). We present and validate the MDPQ and a short 16-question version of the MDPQ (MDPQ-16). The MDPQ, its subscales, and the MDPQ-16 were found to be highly reliable and valid measures of mobile device proficiency in a large sample. We conclude that the MDPQ and MDPQ-16 may serve as useful tools for facilitating mobile device training of older adults and measuring mobile device proficiency for research purposes.

  7. Registry Assessment of Peripheral Interventional Devices (RAPID) - Registry Assessment of Peripheral Interventional Devices Core Data Elements.

    Science.gov (United States)

    Jones, W Schuyler; Krucoff, Mitchell W; Morales, Pablo; Wilgus, Rebecca W; Heath, Anne H; Williams, Mary F; Tcheng, James E; Marinac-Dabic, J Danica; Malone, Misti L; Reed, Terrie L; Fukaya, Rie; Lookstein, Robert; Handa, Nobuhiro; Aronow, Herbert D; Bertges, Daniel J; Jaff, Michael R; Tsai, Thomas T; Smale, Joshua A; Zaugg, Margo J; Thatcher, Robert J; Cronenwett, Jack L; Nc, Durham; Md, Silver Spring; Japan, Tokyo; Ny, New York; Ri, Providence; Vt, Burlington; Mass, Newton; Colo, Denver; Ariz, Tempe; Calif, Santa Clara; Minn, Minneapolis; Nh, Lebanon

    2018-01-25

    The current state of evaluating patients with peripheral artery disease and more specifically of evaluating medical devices used for peripheral vascular intervention (PVI) remains challenging because of the heterogeneity of the disease process, the multiple physician specialties that perform PVI, the multitude of devices available to treat peripheral artery disease, and the lack of consensus about the best treatment approaches. Because PVI core data elements are not standardized across clinical care, clinical trials, and registries, aggregation of data across different data sources and physician specialties is currently not feasible.Methods and Results:Under the auspices of the U.S. Food and Drug Administration's Medical Device Epidemiology Network initiative-and its PASSION (Predictable and Sustainable Implementation of the National Registries) program, in conjunction with other efforts to align clinical data standards-the Registry Assessment of Peripheral Interventional Devices (RAPID) workgroup was convened. RAPID is a collaborative, multidisciplinary effort to develop a consensus lexicon and to promote interoperability across clinical care, clinical trials, and national and international registries of PVI. The current manuscript presents the initial work from RAPID to standardize clinical data elements and definitions, to establish a framework within electronic health records and health information technology procedural reporting systems, and to implement an informatics-based approach to promote the conduct of pragmatic clinical trials and registry efforts in PVI. Ultimately, we hope this work will facilitate and improve device evaluation and surveillance for patients, clinicians, health outcomes researchers, industry, policymakers, and regulators.

  8. Radiation-Tolerance Assessment of a Redundant Wireless Device

    Science.gov (United States)

    Huang, Q.; Jiang, J.

    2018-01-01

    This paper presents a method to evaluate radiation-tolerance without physical tests for a commercial off-the-shelf (COTS)-based monitoring device for high level radiation fields, such as those found in post-accident conditions in a nuclear power plant (NPP). This paper specifically describes the analysis of radiation environment in a severe accident, radiation damages in electronics, and the redundant solution used to prolong the life of the system, as well as the evaluation method for radiation protection and the analysis method of system reliability. As a case study, a wireless monitoring device with redundant and diversified channels is evaluated by using the developed method. The study results and system assessment data show that, under the given radiation condition, performance of the redundant device is more reliable and more robust than those non-redundant devices. The developed redundant wireless monitoring device is therefore able to apply in those conditions (up to 10 M Rad (Si)) during a severe accident in a NPP.

  9. Virtual reality simulators: current status in acquisition and assessment of surgical skills.

    Science.gov (United States)

    Cosman, Peter H; Cregan, Patrick C; Martin, Christopher J; Cartmill, John A

    2002-01-01

    Medical technology is currently evolving so rapidly that its impact cannot be analysed. Robotics and telesurgery loom on the horizon, and the technology used to drive these advances has serendipitous side-effects for the education and training arena. The graphical and haptic interfaces used to provide remote feedback to the operator--by passing control to a computer--may be used to generate simulations of the operative environment that are useful for training candidates in surgical procedures. One additional advantage is that the metrics calculated inherently in the controlling software in order to run the simulation may be used to provide performance feedback to individual trainees and mentors. New interfaces will be required to undergo evaluation of the simulation fidelity before being deemed acceptable. The potential benefits fall into one of two general categories: those benefits related to skill acquisition, and those related to skill assessment. The educational value of the simulation will require assessment, and comparison to currently available methods of training in any given procedure. It is also necessary to determine--by repeated trials--whether a given simulation actually measures the performance parameters it purports to measure. This trains the spotlight on what constitutes good surgical skill, and how it is to be objectively measured. Early results suggest that virtual reality simulators have an important role to play in this aspect of surgical training.

  10. Mersey deanery ophthalmology trainees' views of the objective assessment of surgical and technical skills (OSATS) workplace-based assessment tool.

    Science.gov (United States)

    Tsagkataki, Myrto; Choudhary, Anshoo

    2013-02-01

    Objective assessment of surgical and technical skills (OSATS) workplace-based assessment tool is now mandatory during ophthalmology speciality training in the United Kingdom. The opinions of those undergoing this assessment have not been formally sought. This study evaluated the views of ophthalmology trainees on OSATS assessment as applied to cataract surgery. A questionnaire was circulated to 34 ophthalmology speciality trainees of the Mersey deanery. A total of 28 responses were received. The most positive aspects of the process identified were feedback, learning and opportunity for reflective practice. The most negative aspects were time constraints, assessor's availability and case selection. Of the trainees, 93 % mentioned that no previous agreed action was taken into consideration when filling in subsequent forms and their performance was not discussed in their annual summative assessment. This study highlights important aspects of trainees' perceptions of OSATS. Trainees appreciate the formative aspects of OSATS assessment. Some problems came to light, which can be resolved by specification of standards, training of assessors, and commitment from both trainers and trainees. Changes are needed to allow demonstration of surgical progression with time. The issues identified here will be relevant to other specialities as well. A larger survey would be beneficial.

  11. Adding tactile realism to a virtual reality laparoscopic surgical simulator with a cost-effective human interface device

    Science.gov (United States)

    Mack, Ian W.; Potts, Stephen; McMenemy, Karen R.; Ferguson, R. S.

    2006-02-01

    The laparoscopic technique for performing abdominal surgery requires a very high degree of skill in the medical practitioner. Much interest has been focused on using computer graphics to provide simulators for training surgeons. Unfortunately, these tend to be complex and have a very high cost, which limits availability and restricts the length of time over which individuals can practice their skills. With computer game technology able to provide the graphics required for a surgical simulator, the cost does not have to be high. However, graphics alone cannot serve as a training simulator. Human interface hardware, the equivalent of the force feedback joystick for a flight simulator game, is required to complete the system. This paper presents a design for a very low cost device to address this vital issue. The design encompasses: the mechanical construction, the electronic interfaces and the software protocols to mimic a laparoscopic surgical set-up. Thus the surgeon has the capability of practicing two-handed procedures with the possibility of force feedback. The force feedback and collision detection algorithms allow surgeons to practice realistic operating theatre procedures with a good degree of authenticity.

  12. The consequences of using advanced physical assessment skills in medical and surgical nursing: A hermeneutic pragmatic study.

    Science.gov (United States)

    Zambas, Shelaine I; Smythe, Elizabeth A; Koziol-Mclain, Jane

    2016-01-01

    The aim of this study was to explore the consequences of the nurse's use of advanced assessment skills on medical and surgical wards. Appropriate, accurate, and timely assessment by nurses is the cornerstone of maintaining patient safety in hospitals. The inclusion of "advanced" physical assessment skills such as auscultation, palpation, and percussion is thought to better prepare nurses for complex patient presentations within a wide range of clinical situations. This qualitative study used a hermeneutic pragmatic approach. Unstructured interviews were conducted with five experienced medical and surgical nurses to obtain 13 detailed narratives of assessment practice. Narratives were analyzed using Van Manen's six-step approach to identify the consequences of the nurse's use of advanced assessment skills. The consequences of using advanced assessment skills include looking for more, challenging interpretations, and perseverance. The use of advanced assessment skills directs what the nurse looks for, what she sees, interpretation of the findings, and her response. It is the interpretation of what is seen, heard, or felt within the full context of the patient situation, which is the advanced skill. Advanced assessment skill is the means to an accurate interpretation of the clinical situation and contributes to appropriate diagnosis and medical management in complex patient situations. The nurse's use of advanced assessment skills enables her to contribute to diagnostic reasoning within the acute medical and surgical setting.

  13. Assessment of Surgical and Trauma Capacity in Potosí, Bolivia.

    Science.gov (United States)

    Blair, Kevin J; Boeck, Marissa A; Gallardo Barrientos, José Luis; Hidalgo López, José Luis; Helenowski, Irene B; Nwomeh, Benedict C; Shapiro, Michael B; Swaroop, Mamta

    Scaling up surgical and trauma care in low- and middle-income countries could prevent nearly 2 million annual deaths. Various survey instruments exist to measure surgical and trauma capacity, including Personnel, Infrastructure, Procedures, Equipment, and Supplies (PIPES) and International Assessment of Capacity for Trauma (INTACT). We sought to evaluate surgical and trauma capacity in the Bolivian department of Potosí using a combined PIPES and INTACT tool, with additional questions to further inform intervention targets. In June and July 2014 a combined PIPES and INTACT survey was administered to 20 government facilities in Potosí with a minimum of 1 operating room: 2 third-level, 10 second-level, and 8 first-level facilities. A surgeon, head physician, director, or obstetrician-gynecologist completed the survey. Additional personnel responded to 4 short-answer questions. Survey items were divided into subsections, and PIPES and INTACT indices calculated. Medians were compared via Wilcoxon rank sum and Kruskal-Wallis tests. Six of 20 facilities were located in the capital city and designated urban. Urban establishments had higher median PIPES (8.5 vs 6.7, P = .11) and INTACT (8.5 vs 6.9, P = .16) indices compared with rural. More than half of surgeons and anesthesiologists worked in urban hospitals. Urban facilities had higher median infrastructure and procedure scores compared with rural. Fifty-three individuals completed short-answer questions. Training was most desired in laparoscopic surgery and trauma management; less than half of establishments reported staff with trauma training. Surgical and trauma capacity in Potosí was most limited in personnel, infrastructure, and procedures at rural facilities, with greater personnel deficiencies than previously reported. Interventions should focus on increasing the number of surgical and anesthesia personnel in rural areas, with a particular focus on the reported desire for trauma management training. Results

  14. Multi-perspective workflow modeling for online surgical situation models.

    Science.gov (United States)

    Franke, Stefan; Meixensberger, Jürgen; Neumuth, Thomas

    2015-04-01

    Surgical workflow management is expected to enable situation-aware adaptation and intelligent systems behavior in an integrated operating room (OR). The overall aim is to unburden the surgeon and OR staff from both manual maintenance and information seeking tasks. A major step toward intelligent systems behavior is a stable classification of the surgical situation from multiple perspectives based on performed low-level tasks. The present work proposes a method for the classification of surgical situations based on multi-perspective workflow modeling. A model network that interconnects different types of surgical process models is described. Various aspects of a surgical situation description were considered: low-level tasks, high-level tasks, patient status, and the use of medical devices. A study with sixty neurosurgical interventions was conducted to evaluate the performance of our approach and its robustness against incomplete workflow recognition input. A correct classification rate of over 90% was measured for high-level tasks and patient status. The device usage models for navigation and neurophysiology classified over 95% of the situations correctly, whereas the ultrasound usage was more difficult to predict. Overall, the classification rate decreased with an increasing level of input distortion. Autonomous adaptation of medical devices and intelligent systems behavior do not currently depend solely on low-level tasks. Instead, they require a more general type of understanding of the surgical condition. The integration of various surgical process models in a network provided a comprehensive representation of the interventions and allowed for the generation of extensive situation descriptions. Multi-perspective surgical workflow modeling and online situation models will be a significant pre-requisite for reliable and intelligent systems behavior. Hence, they will contribute to a cooperative OR environment. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. A novel pre-surgical maxillary orthodontic device using β-titanium wire for wide unilateral cleft lip and palate patients: preliminary study of its efficacy and impact for the maxillary formation.

    Science.gov (United States)

    Taniguchi, Maki; Oyama, Tomoki; Kiya, Koichiro; Sone, Yumiko; Ishii, Nobuyuki; Hosokawa, Ko

    2014-02-01

    For patients with a wide, complete, unilateral cleft lip and palate, pre-surgical maxillary orthodontic treatments have been used to reduce the alveolar gap before cheiloplasty. However, most of these treatments are complicated and laborious for patients and for medical professionals. Thus, we developed an original pre-surgical orthodontic device made with two separate acrylic resin plates connected with a spring-shaped β-titanium wire (β-TW). When the device was applied on the palate, each segment of the maxilla was automatically aligned for our target formation with the elastic force of β-titanium alloy. This study aimed to evaluate the efficacy of the new device and the size of the maxilla in comparison with the conventional Hotz procedures. A total of 47 patients with a wide unilateral cleft lip and palate were retrospectively evaluated; 33 patients were treated with our new device (β-TW plate group) and 14 were treated with a Hotz plate (HP group). We evaluated the alveolar gap reduction and the size of the maxilla between the two groups, obtaining intraoral maxillary impressions at birth, at 3 months and 1 year. The width of the alveolar gap in the β-TW plate group was significantly reduced compared with that in the HP group 1 month after the treatment (p pre-surgical orthodontic treatments. Copyright © 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  16. 21 CFR 878.4700 - Surgical microscope and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical microscope and accessories. 878.4700 Section 878.4700 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... microscope and accessories. (a) Identification. A surgical microscope and accessories is an AC-powered device...

  17. TextWithSurgeryPatients - A Research Hypothesis in Enhancing Education and Physical Assessment for Abdominal Surgical Patients.

    Science.gov (United States)

    Hansen, Margaret

    2016-01-01

    Medical surgical nurses may not have the time or resources to provide effective pre- and post-operative instructions for patients in today's healthcare system. And, making timely physical assessments following discharge from the hospital is not always straightforward. Therefore, the risk for readmission associated with post-surgical complications is a concern. At present, mobile healthcare technologies and patient care are precipitously evolving and may serve as a resource to enhance communication between the healthcare provider and patient. A mobile telephone text message (short message service [SMS]) intervention for abdominal surgical patients may foster effective education (communication) and timely self-reported physical assessment in the home environment hence preventing deleterious outcomes. The aim of this research proposal is to identify the feasibility of using a SMS intervention via smart phones to improve health outcomes via timely communication, reach large numbers of at-risk surgical patients and, establish and sustain uniform protocols in a cost-efficient manner.

  18. What are estimated reimbursements for lower extremity prostheses capable of surgical and nonsurgical lengthening?

    Science.gov (United States)

    Henderson, Eric R; Pepper, Andrew M; Letson, G Douglas

    2012-04-01

    Growing prostheses accommodate skeletally immature patients with bone tumors undergoing limb-preserving surgery. Early devices required surgical procedures for lengthening; recent devices lengthen without surgery. Expenses for newer expandable devices that lengthen without surgery are more than for their predecessors but overall reimbursement amounts are not known. We sought to determine reimbursement amounts associated with lengthening of growing prostheses requiring surgical and nonsurgical lengthening. We retrospectively reviewed 17 patients with growing prostheses requiring surgical expansion and eight patients with prostheses capable of nonsurgical expansion. Insurance documents were reviewed to determine the reimbursement for implantation, lengthening, and complications. Growth data were obtained from the literature. Mean reimbursement amounts of surgical and nonsurgical lengthenings were $9950 and $272, respectively. Estimated reimbursements associated with implantation of a growing prosthesis varied depending on age, sex, and location. The largest difference was found for 4-year-old boys with distal femoral replacement where reimbursement for expansion to maturity for surgical and nonsurgical lengthening prostheses would be $379,000 and $208,000, respectively. For children requiring more than one surgical expansion, net reimbursements were lower when a noninvasive lengthening device was used. Annual per-prosthesis maintenance reimbursements to address complications for surgical and nonsurgical lengthening prostheses were $3386 and $1856, respectively. This study showed that reimbursements for lengthening of growing endoprostheses capable of nonsurgical expansion may be less expensive in younger patients, particularly male patients undergoing distal femur replacement, than endoprostheses requiring surgical lengthening. Longer outcomes studies are required to see if reimbursements for complications differ between devices. Level III, economic and decision

  19. [da Vinci surgical system].

    Science.gov (United States)

    Watanabe, Gou; Ishikawa, Norihiro

    2014-07-01

    The da Vinci surgical system was developed by Intuitive Surgical Inc. in the United States as an endoscopic surgical device to assist remote control surgeries. In 1998, the Da Vinci system was first used for cardiothoracic procedures. Currently a combination of robot-assisted internal thoracic artery harvest together with coronary artery bypass grafting (CABG) through a mini-incision (ThoraCAB) or totally endoscopic procedures including anastomoses under robotic assistance (TECAB) are being conducted for the treatment of coronary artery diseases. With the recent advances in catheter interventions, hybrid procedures combining catheter intervention with ThoraCAB or TECAB are anticipated in the future.On the other hand, with the decrease in number of coronary artery bypass surgeries, the share of valvular surgeries is expected to increase in the future. Among them, mitral valvuloplasty for mitral regurgitation is anticipated to be conducted mainly by low-invasive procedures, represented by minimally invasive cardiac surgery( MICS) and robot-assisted surgery. Apart from the intrinsic good surgical view, robotic-assisted systems offer additional advantages of the availability of an amplified view and the easy to observe the mitral valve in the physiological position. Thus, robotic surgical surgeries that make complicated procedures easier are expected to accomplish further developments in the future. Furthermore, while the number of surgeries for atrial septal defects has decreased dramatically following the widespread use of Amplatzer septal occluder, robotic surgery may become a good indication for cases in which the Amplatzer device is not indicated. In Japan, clinical trial of the da Vinci robotic system for heart surgeries has been completed. Statutory approval of the da Vinci system for mitral regurgitation and atrial septal defects is anticipated in the next few years.

  20. Changes after surgically-assisted maxillary expansion (SARME) to the dentoalveolar, palatal and nasal structures by using tooth-borne distraction devices.

    Science.gov (United States)

    Seeberger, Robin; Kater, Wolfgang; Schulte-Geers, Michael; Davids, Rolf; Freier, Kolja; Thiele, Oliver

    2011-07-01

    Different devices are available to aid surgically-assisted maxillary expansion. In this study we have evaluated the changes to the anchoring teeth, the hard palate, and the lower nasal passage made by tooth-borne distraction devices. Thirty-one patients (mean (SD) age 28 (2) years) with deficiencies in the transverse width of the maxilla were examined by computed tomography and cone beam scans before and after operation. The data were analysed with the help of Wilcoxon's signed rank test and Spearman's r correlation. The mean (SD) distraction width was 6.5 (2.3) mm. All anchorage teeth were tilted (pdistraction width, with changes in the intercoronal and interapical distances of the anchoring premolars (pdistraction width and the overall gain in width of the lower nasal passage (pmaxillary expansion with tooth-borne devices has significant effects on the anchoring teeth, the nasal floor, and the hard palate. Both tilting of the teeth and an evenly distributed movement of the segments were seen. Copyright © 2010 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Assessment of Educational Environment of Surgical Theatre at a Teaching Hospital of a Saudi University: Using Surgical Theatre Educational Environment Measures

    Directory of Open Access Journals (Sweden)

    Mona Faisal Al-Qahtani

    2012-05-01

    Full Text Available Objectives: This study was aimed to determine how medical interns perceive the important factors of the learning environment the surgical theatre at the teaching hospital of the medical school, University of Dammam (UoD. The study also investigated the relationships between the learning environment and academic achievements. Finally, it determined the role and significance of gender on the above perceptions and relationships.Methods: The Surgical Theatre Educational Environment Measure (STEEM was used to identify the perceptions of interns on the most important factors prevalent in the surgical theatre as an educational environment. STEEM was administered to all interns during the period of June-September 2009. Ninety-one out of 145 students completed the questionnaire representing a response rate of 63%. Non-parametric statistical analysis was performed using Statistical Package for the Social Sciences (SPSS Version 17.Results: The STEEM was shown to be internally consistent for the assessment of the overall educational environment in the surgical theatre of UoD. The overall STEEM mean score was 110. For male and female students, the mean scores were 114 and 107 respectively. There were statistically significant gender differences in the perceptions of "learning opportunities" and "teaching and training". Females rated these subscales lower than males. There were no significant associations between academic achievements and perceptions of the educational environment.Conclusion: The interns perceived the learning environment of the surgical theatre as less than satisfactory. In comparison with the males; the perception of the females was less positive, particularly in the areas of learning opportunities, and teaching and training. The study also revealed some other problematic areas in the learning environment of surgical theatre of the teaching hospital of UoD. The results imply that there is much room for improvement. They also indicate that

  2. [NIC as a tool for assessing competences of nursing students in clinical placement at surgical units].

    Science.gov (United States)

    Celma Vicente, Matilde; Ajuria-Imaz, Eloisa; Lopez-Morales, Manuel; Fernandez-Marín, Pilar; Menor-Castro, Alicia; Cano-Caballero Galvez, Maria Dolores

    2015-01-01

    This paper shows the utility of a NIC standardized language to assess the extent of nursing student skills at Practicum in surgical units To identify the nursing interventions classification (NIC) that students can learn to perform in surgical units. To determine the level of difficulty in learning interventions, depending on which week of rotation in clinical placement the student is. Qualitative study using Delphi consensus technique, involving nurses with teaching experience who work in hospital surgical units, where students undertake the Practicum. The results were triangulated through a questionnaire to tutors about the degree of conformity. A consensus was reached about the interventions that students can achieve in surgical units and the frequency in which they can be performed. The level of difficulty of each intervention, and the amount of weeks of practice that students need to reach the expected level of competence was also determined. The results should enable us to design better rotations matched to student needs. Knowing the frequency of each intervention that is performed in each unit determines the chances of learning it, as well as the indicators for its assessment. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  3. Towards reducing thrombogenicity of LVAD therapy: optimizing surgical and patient management strategies

    Science.gov (United States)

    Chivukula, Venkat Keshav; Lafzi, Ali; Mokadam, Nahush; Beckman, Jennifer; Mahr, Claudius; Aliseda, Alberto

    2017-11-01

    Unfavourable hemodynamics in heart failure patients implanted with left ventricular assist devices (LVAD), due to non-optimal surgical configurations and patient management, strongly influence thrombogenicity. This is consistent with the increase in devastating thromboembolic complications (specifically thrombosis and stroke) in patients, even as the risk of thrombosis inside the device decreases with modern designs. Inflow cannula and outflow graft surgical configurations have been optimized via patient-specific modeling that computes the thrombogenic potential with a combination of Eulerian (endothelial) wall shear stress and Lagrangian (platelet shear history) tracking. Using this view of hemodynamics, the benefits of intermittent aortic valve opening (promoting washout and reducing stagnant flow in the aortic valve region) have been assessed in managing the patient's residual native cardiac output. The use of this methodology to understand the contribution of the hemodynamics in the flow surrounding the LVAD itself to thrombogenesis show promise in developing holistic patient-specific management strategies to minimize stroke risk and enhance efficacy of LVAD therapy. Funded in part by an AHA postdoctoral fellowship 16POST30520004.

  4. Surgical ergonomics. Analysis of technical skills, simulation models and assessment methods.

    Science.gov (United States)

    Papaspyros, Sotiris C; Kar, Ashok; O'Regan, David

    2015-06-01

    Over the past two centuries the surgical profession has undergone a profound evolution in terms of efficiency and outcomes. Societal concerns in relation to quality assurance, patient safety and cost reduction have highlighted the issue of training expert surgeons. The core elements of a training model build on the basic foundations of gross and fine motor skills. In this paper we provide an analysis of the ergonomic principles involved and propose relevant training techniques. We have endeavored to provide both the trainer and trainee perspectives. This paper is structured into four sections: 1) Pre-operative preparation issues, 2) technical skills and instrument handling, 3) low fidelity simulation models and 4) discussion of current concepts in crew resource management, deliberate practice and assessment. Rehearsal, warm-up and motivation-enhancing techniques aid concentration and focus. Appropriate posture, comprehension of ergonomic principles in relation to surgical instruments and utilisation of the non-dominant hand are essential skills to master. Low fidelity models can be used to achieve significant progress through the early stages of the learning curve. Deliberate practice and innate ability are complementary to each other and may be considered useful adjuncts to surgical skills development. Safe medical care requires that complex patient interventions be performed by highly skilled operators supported by reliable teams. Surgical ergonomics lie at the heart of any training model that aims to produce professionals able to function as leaders of a patient safety oriented culture. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  5. Input and output for surgical simulation: devices to measure tissue properties in vivo and a haptic interface for laparoscopy simulators.

    Science.gov (United States)

    Ottensmeyer, M P; Ben-Ur, E; Salisbury, J K

    2000-01-01

    Current efforts in surgical simulation very often focus on creating realistic graphical feedback, but neglect some or all tactile and force (haptic) feedback that a surgeon would normally receive. Simulations that do include haptic feedback do not typically use real tissue compliance properties, favoring estimates and user feedback to determine realism. When tissue compliance data are used, there are virtually no in vivo property measurements to draw upon. Together with the Center for Innovative Minimally Invasive Therapy at the Massachusetts General Hospital, the Haptics Group is developing tools to introduce more comprehensive haptic feedback in laparoscopy simulators and to provide biological tissue material property data for our software simulation. The platform for providing haptic feedback is a PHANToM Haptic Interface, produced by SensAble Technologies, Inc. Our devices supplement the PHANToM to provide for grasping and optionally, for the roll axis of the tool. Together with feedback from the PHANToM, which provides the pitch, yaw and thrust axes of a typical laparoscopy tool, we can recreate all of the haptic sensations experienced during laparoscopy. The devices integrate real laparoscopy toolhandles and a compliant torso model to complete the set of visual and tactile sensations. Biological tissues are known to exhibit non-linear mechanical properties, and change their properties dramatically when removed from a living organism. To measure the properties in vivo, two devices are being developed. The first is a small displacement, 1-D indenter. It will measure the linear tissue compliance (stiffness and damping) over a wide range of frequencies. These data will be used as inputs to a finite element or other model. The second device will be able to deflect tissues in 3-D over a larger range, so that the non-linearities due to changes in the tissue geometry will be measured. This will allow us to validate the performance of the model on large tissue

  6. Plans for Hand-Held/Portable Oil Assessment Devices

    National Research Council Canada - National Science Library

    Urbansky, Edward

    2005-01-01

    At the request of the U.S. Army Oil Analysis Program, the JOAP TSC conducted a market study, assembled a plan of action, and prepared a worksheet for the evaluation of portable or hand-held oil assessment devices...

  7. An Interesting Case Report of Unexpected VSD Device Embolization and its Challenging Percutaneous Retrieval

    Directory of Open Access Journals (Sweden)

    Vinod Raghunath Revankar

    2015-01-01

    Full Text Available Device closure of Ventricular septal defect (VSD is gaining popularity as a preferred method of treatment in suitable patients. The decreased morbidity and mortality associated with the procedure as compared to open heart surgery is the main reason behind this. Device embolization is a dreaded complication that occurs rarely with this procedure. While surgical retrieval of the device is preferred at most centres, the device can be retrieved per cutaneously by employing suitable maneuvers. We are reporting a case where we successfully retrieved an embolized ADOII device in our patient. We intend to emphasize the need for thorough pre operative assessment of the patient before proceeding with device closure in order to prevent this complication from occurring.

  8. ['Clinical auditing', a novel tool for quality assessment in surgical oncology].

    Science.gov (United States)

    van Leersum, Nicoline J; Kolfschoten, Nikki E; Klinkenbijl, Jean H G; Tollenaar, Rob A E M; Wouters, Michel W J M

    2011-01-01

    To determine whether systematic audit and feedback of information about the process and outcomes improve the quality of surgical care. Systematic literature review. Embase, PubMed, and Web of Science databases were searched for publications on 'quality assessment' and 'surgery'. The references of the publications found were examined as well. Publications were included in the review if the effect of auditing on the quality of surgical care had been investigated. In the databases 2415 publications were found. After selection, 28 publications describing the effect of auditing, whether or not combined with a quality improvement project, on guideline adherence or indications of outcomes of care were included. In 21 studies, a statistically significant positive effect of auditing was reported. In 5 studies a positive effect was found, but this was either not significant or statistical significance was not determined. In 2 studies no effect was observed. 5 studies compared the combination of auditing with a quality improvement project with auditing alone; 4 of these reported an additional effect of the quality improvement project. Audit and feedback of quality information seem to have a positive effect on the quality of surgical care. The use of quality information from audits for the purpose of a quality improvement project can enhance the positive effect of the audit.

  9. Using an original triage and on call management tool aids identification and assessment of the acutely unwell surgical patient.

    Science.gov (United States)

    Hodge, Stacie; Helliar, Sebastian; Macdonald, Hamish Ian; Mackey, Paul

    2018-01-01

    Until now, there have been no published surgical triage tools. We have developed the first such tool with a tiered escalation policy, aiming to improve identification and management of critically unwell patients. The existing sheet which is used to track new referrals and admissions to the surgical assessment unit was reviewed. The sheet was updated and a traffic light triage tool generated using National Early Warning Scores (NEWS), sepsis criteria and user discretion. A tiered escalation policy to guide urgency of assessment was introduced and education sessions for all staff undertaken, to ensure understanding and compliance. Through multiple 'plan-do-study-act' cycles, the new system and its efficiency have been analysed. Prior to intervention, documentation of NEWS did not occur and only 13% of admission observations were communicated to the surgical team. Following multiple cycles and interventions, 93% of patients were fully triaged, and 80% of 'red' and 'amber' patients' observations were communicated to the surgical team. The average time for a registrar to review a 'red' patient was 37 min and 79% of 'green' patients were reviewed within an hour of their presentation. Rapid identification of the unwell patient is crucial. Here we publish the first triage tool that enables early assessment of septic and otherwise potentially unwell surgical patients.

  10. Left Atrial Appendage Closure Device With Delivery System: A Health Technology Assessment

    Science.gov (United States)

    Nevis, Immaculate; Falk, Lindsey; Wells, David; Higgins, Caroline

    2017-01-01

    Background Atrial fibrillation is a common cardiac arrhythmia, and 15% to 20% of those who have experienced stroke have atrial fibrillation. Treatment options to prevent stroke in people with atrial fibrillation include pharmacological agents such as novel oral anticoagulants or nonpharmacological devices such as the left atrial appendage closure device with delivery system (LAAC device). The objectives of this health technology assessment were to assess the clinical effectiveness and cost-effectiveness of the LAAC device versus novel oral anticoagulants in patients without contraindications to oral anticoagulants and versus antiplatelet agents in patients with contraindications to oral anticoagulants. Methods We performed a systematic review and network meta-analysis. We also conducted an economic literature review, economic evaluation, and budget impact analysis to assess the cost-effectiveness and budget impact of the LAAC device compared with novel oral anticoagulants and oral antiplatelet agents (e.g., aspirin). We also spoke with patients to better understand their preferences, perspectives, and values. Results Seven randomized controlled studies met the inclusion criteria for indirect comparison. Five studies assessed the effectiveness of novel oral anticoagulants versus warfarin, and two studies compared the LAAC device with warfarin. No studies were identified that compared the LAAC device with aspirin in patients in whom oral anticoagulants were contraindicated. Using the random effects model, we found that the LAAC device was comparable to novel oral anticoagulants in reducing stroke (odds ratio [OR] 0.85; credible interval [Cr.I] 0.63–1.05). Similarly, the reduction in the risk of all-cause mortality was comparable between the LAAC device and novel oral anticoagulants (OR 0.71; Cr.I 0.49–1.22). The LAAC device was found to be superior to novel oral anticoagulants in preventing hemorrhagic stroke (OR 0.45; Cr.I 0.29–0.79), whereas novel oral

  11. Validating the Accuracy of Reaction Time Assessment on Computer-Based Tablet Devices.

    Science.gov (United States)

    Schatz, Philip; Ybarra, Vincent; Leitner, Donald

    2015-08-01

    Computer-based assessment has evolved to tablet-based devices. Despite the availability of tablets and "apps," there is limited research validating their use. We documented timing delays between stimulus presentation and (simulated) touch response on iOS devices (3rd- and 4th-generation Apple iPads) and Android devices (Kindle Fire, Google Nexus, Samsung Galaxy) at response intervals of 100, 250, 500, and 1,000 milliseconds (ms). Results showed significantly greater timing error on Google Nexus and Samsung tablets (81-97 ms), than Kindle Fire and Apple iPads (27-33 ms). Within Apple devices, iOS 7 obtained significantly lower timing error than iOS 6. Simple reaction time (RT) trials (250 ms) on tablet devices represent 12% to 40% error (30-100 ms), depending on the device, which decreases considerably for choice RT trials (3-5% error at 1,000 ms). Results raise implications for using the same device for serial clinical assessment of RT using tablets, as well as the need for calibration of software and hardware. © The Author(s) 2015.

  12. Gynaecological Endoscopic Surgical Education and Assessment. A diploma programme in gynaecological endoscopic surgery.

    Science.gov (United States)

    Campo, Rudi; Wattiez, Arnaud; Tanos, Vasilis; Di Spiezio Sardo, Attilio; Grimbizis, Grigoris; Wallwiener, Diethelm; Brucker, Sara; Puga, Marco; Molinas, Roger; O'Donovan, Peter; Deprest, Jan; Van Belle, Yves; Lissens, Ann; Herrmann, Anja; Tahir, Mahmood; Benedetto, Chiara; Siebert, Igno; Rabischong, Benoit; De Wilde, Rudy Leon

    2016-04-01

    In recent years, training and education in endoscopic surgery has been critically reviewed. Clinicians, both surgeons as gynaecologist who perform endoscopic surgery without proper training of the specific psychomotor skills are at higher risk to increased patient morbidity and mortality. Although the apprentice-tutor model has long been a successful approach for training of surgeons, recently, clinicians have recognised that endoscopic surgery requires an important training phase outside the operating theatre. The Gynaecological Endoscopic Surgical Education and Assessment programme (GESEA), recognises the necessity of this structured approach and implements two separated stages in its learning strategy. In the first stage, a skill certificate on theoretical knowledge and specific practical psychomotor skills is acquired through a high stake exam; in the second stage, a clinical programme is completed to achieve surgical competence and receive the corresponding diploma. Three diplomas can be awarded: (a) the Bachelor in Endoscopy; (b) the Minimally Invasive Gynaecological Surgeon (MIGS); and (c) the Master level. The Master level is sub-divided into two separate diplomas: the Master in Laparoscopic Pelvic Surgery and the Master in Hysteroscopy. The complexity of modern surgery has increased the demands and challenges to surgical education and the quality control. This programme is based on the best available scientific evidence and it counteracts the problem of the traditional surgical apprentice tutor model. It is seen as a major step toward standardization of endoscopic surgical training in general. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. 21 CFR 878.4730 - Surgical skin degreaser or adhesive tape solvent.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Surgical skin degreaser or adhesive tape solvent... Surgical skin degreaser or adhesive tape solvent. (a) Identification. A surgical skin degreaser or an adhesive tape solvent is a device that consists of a liquid such as 1,1,2-trichloro-1,2,2-trifluoroethane...

  14. A UK perspective on smartphone use amongst doctors within the surgical profession.

    Science.gov (United States)

    Patel, Rikesh K; Sayers, Adele E; Patrick, Nina L; Hughes, Kaylie; Armitage, Jonathan; Hunter, Iain Andrew

    2015-06-01

    Hospitals are increasingly looking for mobile solutions to meet their information technology needs. Medical professionals are using personal mobile devices to support their work, because of limitations in both time and space. Our aims were to assess smartphone use amongst UK surgical doctors, the prevalence of medical app use and online activity. A thirteen-item questionnaire was derived to identify the proportion of surgical doctors of all grades using smartphones within the workplace. The following factors were evaluated: use of medical apps; use of online medical resources and if users were willing to use their own smartphone for clinical use. A total of 341 participants were surveyed with a complete response rate: 93.5% of which owned a smartphone, with 54.2% of those owning medical apps and 86.2% using their device to access online medical resources. Junior doctors were more likely to use medical apps over their senior colleagues (p = 0.001) as well as access the Internet on their smartphone for medical information (p smartphone for clinical use, which was found not to be dependent on seniority (p = 0.922). Online resources contribute significantly to clinical activities with the majority of smartphone users willing to use their own device. The information gathered from this study can aid developers to create software dedicated to the smartphone operating systems in greatest use and to potentially increase the use of a bring your own device (BYOD) scheme.

  15. Development of a Device for Objective Assessment of Tinnitus in Humans

    Science.gov (United States)

    2017-10-01

    AWARD NUMBER: W81XWH-14-2-0180 TITLE: Development of a Device for Objective Assessment of Tinnitus in Humans PRINCIPAL INVESTIGATOR: Jeremy G...SUBTITLE Development of a Device for Objective Assessment of Tinnitus in Humans 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-14-2-0180 5c. PROGRAM...briefly (one paragraph) describes the subject, purpose and scope of the research. Tinnitus is the perception of sound in the ears or head when no

  16. Comparing two intramedullary devices for treating trochanteric fractures: A prospective study

    Directory of Open Access Journals (Sweden)

    Kontogeorgakos Vasileios

    2010-02-01

    Full Text Available Abstract Background Intertrochanteric fractures are surgically treated by using different methods and implants. The optional type of surgical stabilization is still under debate. However, between devices with the same philosophy, different design characteristics may substantially influence fracture healing. This is a prospective study comparing the complication and final functional outcome of two intramedullary devices, the intramedullary hip screw (IMHS and the ENDOVIS nail. Materials and methods Two hundred fifteen patients were randomized on admission in two treatment groups. Epidemiology features and functional status was similar between two treatment groups. Fracture stability was assessed according to the Evan's classification. One hundred ten patients were treated with IMHS and 105 with ENDOVIS nail. Results There were no significant statistical differences between the two groups regarding blood loss, transfusion requirements and mortality rate. In contrast, the number of total complications was significantly higher in the ENDOVIS nail group. Moreover, the overall functional and walking competence was superior in the patients treated with the IMHS nail. Conclusions These results indicate that the choice of the proper implant plays probably an important role in the final outcome of surgical treatment of intertrochanteric fractures. IMHS nail allows for accurate surgical technique, for both static and dynamic compression and high rotational stability. IMHS nail proved more reliable in our study regarding nail insertion and overall uncomplicated outcome.

  17. Acceptability and feasibility of mini-clinical evaluation exercise as a formative assessment tool for workplace-based assessment for surgical postgraduate students

    Directory of Open Access Journals (Sweden)

    M K Joshi

    2017-01-01

    Full Text Available Background: Despite an increasing emphasis on workplace-based assessment (WPBA during medical training, the existing assessment system largely relies on summative assessment while formative assessment is less valued. Various tools have been described for WPBA, mini-clinical evaluation exercise (mini-CEX being one of them. Mini-CEX is well accepted in Western countries, however, reports of its use in India are scarce. We conducted this study to assess acceptability and feasibility of mini-CEX as a formative assessment tool for WPBA of surgical postgraduate students in an Indian setting. Methods: Faculty members and 2nd year surgical residents were sensitized toward mini-CEX and requisite numbers of exercises were conducted. The difficulties during conduction of these exercises were identified, recorded, and appropriate measures were taken to address them. At the conclusion, the opinion of residents and faculty members regarding their experience with mini-CEX was taken using a questionnaire. The results were analyzed using simple statistical tools. Results: Nine faculty members out of 11 approached participated in the study (81.8%. All 16 2nd year postgraduate surgical residents participated (100%. Sixty mini-CEX were conducted over 7 months. Each resident underwent 3–5 encounters. The mean time taken by the assessor for observation was 12.3 min (8–30 min while the mean feedback time was 4.2 min (3–10 min. The faculty reported good overall satisfaction with mini-CEX and found it acceptable as a formative assessment tool. Three faculty members (33.3% reported mini-CEX as more time-consuming while 2 (22.2% found it difficult to carry the exercises often. All residents accepted mini-CEX and most of them reported good to high satisfaction with the exercises conducted. Conclusions: Mini-CEX is well accepted by residents and faculty as a formative assessment tool. It is feasible to utilize mini-CEX for WPBA of postgraduate students of surgery.

  18. Radiation damage assessment of Nb tunnel junction devices

    International Nuclear Information System (INIS)

    King, S.E.; Magno, R.; Maisch, W.G.

    1991-01-01

    This paper reports on the radiation hardness of a new technology using Josephson junctions that was explored by an irradiation using a fluence of 7.6 x 10 14 protons/cm 2 at an energy of 63 MeV from the U.C. Davis cyclotron. In what the authors believe is the first radiation assessment of Nb/Al 2 O 3 /Nb devices, the permanent damage in these devices was investigated. No permanent changes in the I-V characteristics of the junctions were observed indicating no significant level of material defects have occurred at this level of irradiation

  19. Development and validation of a composite scoring system for robot-assisted surgical training--the Robotic Skills Assessment Score.

    Science.gov (United States)

    Chowriappa, Ashirwad J; Shi, Yi; Raza, Syed Johar; Ahmed, Kamran; Stegemann, Andrew; Wilding, Gregory; Kaouk, Jihad; Peabody, James O; Menon, Mani; Hassett, James M; Kesavadas, Thenkurussi; Guru, Khurshid A

    2013-12-01

    A standardized scoring system does not exist in virtual reality-based assessment metrics to describe safe and crucial surgical skills in robot-assisted surgery. This study aims to develop an assessment score along with its construct validation. All subjects performed key tasks on previously validated Fundamental Skills of Robotic Surgery curriculum, which were recorded, and metrics were stored. After an expert consensus for the purpose of content validation (Delphi), critical safety determining procedural steps were identified from the Fundamental Skills of Robotic Surgery curriculum and a hierarchical task decomposition of multiple parameters using a variety of metrics was used to develop Robotic Skills Assessment Score (RSA-Score). Robotic Skills Assessment mainly focuses on safety in operative field, critical error, economy, bimanual dexterity, and time. Following, the RSA-Score was further evaluated for construct validation and feasibility. Spearman correlation tests performed between tasks using the RSA-Scores indicate no cross correlation. Wilcoxon rank sum tests were performed between the two groups. The proposed RSA-Score was evaluated on non-robotic surgeons (n = 15) and on expert-robotic surgeons (n = 12). The expert group demonstrated significantly better performance on all four tasks in comparison to the novice group. Validation of the RSA-Score in this study was carried out on the Robotic Surgical Simulator. The RSA-Score is a valid scoring system that could be incorporated in any virtual reality-based surgical simulator to achieve standardized assessment of fundamental surgical tents during robot-assisted surgery. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Preclinical evaluation of the effect of the combined use of the Ethicon Securestrap® Open Absorbable Strap Fixation Device and Ethicon Physiomesh™ Open Flexible Composite Mesh Device on surgeon stress during ventral hernia repair

    Directory of Open Access Journals (Sweden)

    Sutton N

    2017-12-01

    Full Text Available Nadia Sutton,1 Melinda H MacDonald,2 John Lombard,1 Bodgan Ilie,3 Piet Hinoul,4 Douglas A Granger5,6 1Global Health Economics and Market Access, Johnson & Johnson Medical Devices, New Brunswick, NJ, USA; 2Preclinical Center of Excellence, Johnson & Johnson Medical Devices Companies, Somerville, NJ, USA; 3Biostatistics, Ethicon, Somerville, NJ, USA; 4Medical Affairs, Ethicon, Somerville, NJ, USA; 5Institute for Interdisciplinary Salivary Bioscience Research (IISBR, University of California at Irvine, Irvine, CA, USA; 6Johns Hopkins University School of Nursing, Bloomberg School of Public Health, and School of Medicine, Baltimore, MD, USA Aim: To evaluate whether performing ventral hernia repairs using the Ethicon Physiomesh™ Open Flexible Composite Mesh Device in conjunction with the Ethicon Securestrap® Open Absorbable Strap Fixation Device reduces surgical time and surgeon stress levels, compared with traditional surgical repair methods. Methods: To repair a simulated ventral incisional hernia, two surgeries were performed by eight experienced surgeons using a live porcine model. One procedure involved traditional suture methods and a flat mesh, and the other procedure involved a mechanical fixation device and a skirted flexible composite mesh. A Surgery Task Load Index questionnaire was administered before and after the procedure to establish the surgeons’ perceived stress levels, and saliva samples were collected before, during, and after the surgical procedures to assess the biologically expressed stress (cortisol and salivary alpha amylase levels. Results: For mechanical fixation using the Ethicon Physiomesh Open Flexible Composite Mesh Device in conjunction with the Ethicon Securestrap Open Absorbable Strap Fixation Device, surgeons reported a 46.2% reduction in perceived workload stress. There was also a lower physiological reactivity to the intraoperative experience and the total surgical procedure time was reduced by 60

  1. Intracavitary deposits on Essure® hysteroscopic sterilization devices : A case report

    OpenAIRE

    Maassen, L. W.; van Gastel, Maatje D A; Lentjes, E. G.W.M.; Bongers, M. Y.; Veersema, S.

    2017-01-01

    Objective: To study the composition of intracavitary deposits on Essure® hysteroscopic sterilization devices. Design: Case report. Setting: Reproductive Medicine and Gynecology department of a University Hospital. Patient(s): A 39 years old patient presenting with a request for surgical removal of Essure® sterilization devices. Diagnostic hysteroscopy showed a crystal like white deposit attached to one of the devices. Intervention: Diagnostic hysteroscopy and surgical removal of E...

  2. Assessment Of Common Surgical Conditions ~ncountered Py cal ...

    African Journals Online (AJOL)

    on-the-job training by visiting specialists and training at a referral facility as the best method to improve their surgical skills so as to competently deal with major surgical problems in their area. The majority (85%) of the respondents preferred that training should take 6-12 months. Medical officers, supported by periodic visits ...

  3. Epidemiology and treatment outcome of surgically treated mandibular condyle fractures. A five years retrospective study.

    Science.gov (United States)

    Zrounba, Hugues; Lutz, Jean-Christophe; Zink, Simone; Wilk, Astrid

    2014-09-01

    Surgical management of mandibular condyle fractures is still controversial. Although it provides better outcome than closed treatment questions still remain about the surgical approach and the osteosynthesis devices to be used. Between 2005 and 2010, we managed 168 mandibular condyle fractures with open treatment. Two surgical approaches were used in this study, a pre-auricular and a high submandibular approach (one or the other or as a combined approach). Internal fixation was performed using TCP(®) plates (Medartis, Basel, Switzerland) or with two lag screws (15 and 17 mm). Delta plates were used in 15 cases (8.9%). We report the epidemiology of these fractures and the outcomes of the surgical treatment. We assessed the complications related to the surgical procedure and those related to the osteosynthesis material. The facial nerve related complication rate was very low and the osteosynthesis materials used proved to be strong enough to realize a stable fixation. The two approaches used in this study appeared to be safe with good aesthetic results. Most of the surgical procedure failures occurred in high subcondylar fractures especially when bilateral. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  4. Single-centre experience of radiation exposure in acute surgical patients: assessment of therapeutic impact and future recommendations.

    Science.gov (United States)

    Fitzmaurice, Gerard J; Brown, Robin; Cranley, Brian; Conlon, Enda F; Todd, R Alan J; O'Donnell, Mark E

    2010-09-01

    Radiological investigations have become a key adjunct in patient management and consequently radiation exposure to patients is increasing. The study objectives were to examine the use of radiological investigations in the management of acute surgical patients and to assess whether a guideline-based radiation exposure risk/benefit analysis can aid in the choice of radiological investigation used. A prospective observational study was completed over a 12-week period from April to July 2008 for all acute surgical admissions. Data recorded included demographics, clinical presentation, differential diagnosis, investigations, surgical interventions, and final clinical outcome. The use of radiological investigative modalities as an adjunct to clinical assessment was then evaluated against The Royal College of Radiologists (RCR) guidelines. A total of 380 acute surgical admissions (M = 174, F = 185, children = 21) were assessed during the study period. Seven hundred thirty-four radiological investigations were performed with a mean of 1.93 investigations per patient. Based on the RCR guidelines, 680 (92.6%) radiological investigations were warranted and included 142 CT scans (19.3%), 129 chest X-rays (17.6%), and 85 abdominal X-rays (11.6%). Clinically, radiological imaging complemented surgical management in 326 patients (85.8%) and the management plan remained unchanged for the remaining 54 patients (14.2%). This accounted for an average radiation dose of 4.18 millisievert (mSv) per patient or 626 days of background radiation exposure. CT imaging was responsible for the majority of the radiation exposure, with a total of 1310 mSv (82.6%) of the total radiation exposure being attributed to CT imaging in 20.8% of acute admissions. Subgroup analysis demonstrated that 92.8% of the CT scans performed were appropriate. Radiation exposure was generally low for the majority of acute surgical admissions. However, it is recommended that CT imaging requests be evaluated carefully

  5. Surgical Competence: Assessing, Acquiring, Maintaining, and ...

    African Journals Online (AJOL)

    Hp 630 Dual Core

    Emeritus Professor of Paediatric Surgery, Royal Aberdeen Children s ... Formerly Vice President of the Royal College of Surgeons of Edinburgh ... where a highly critical if not toxic climate of low tolerance of surgical failure, with judicial,.

  6. [Assessment of surgical teleconsultations in a developing country: two years of experience in Djibouti].

    Science.gov (United States)

    Bertani, A; Menguy, P; Delmas, J M; Launay, F; Mathieu, L; Candoni, P; Dulou, R; Rongiéras, F

    2012-01-01

    Our objective was to assess the influence of teleconsultations on patient management and clinical outcomes in a developing country. All the surgical teleconsultations by a single surgeon (orthopedist) between November 2009 and November 2011 were recorded. Neurosurgery and pediatric orthopedics were the two most important specialities most often concerned, accounting for 67% of the 157 teleconsultations for 138 patients. The teleconsultations resolved the diagnostic uncertainties in 29 of 37 cases (78%). Advice from the expert modified management in 69% cases. Clinical outcomes were good or very good in 86% of the treated patients. This study establishes the feasibility and usefulness of surgical teleconsultations in Djibouti.

  7. First report on joint use of a Da Vinci® surgical system with transfer of surgical know-how between two public hospitals.

    Science.gov (United States)

    Mattei, Agostino; Thoms, Michael; Ferrari, Matteo; La Croce, Giovanni; Danuser, Hansjörg; Schmid, Hans-Peter; Engeler, Daniel

    2014-01-01

    The costs of a Da Vinci® device for robot- assisted surgery, in particular for robot-assisted radical prostatectomy (RARP), can be a considerable issue for hospitals with limited caseloads. Since January 2011 the cantonal hospitals of Lucerne and St. Gallen (Switzerland) have shared a four-arm Da Vinci® device, transferring the surgical know-how by a Lucerne teaching surgeon to a St. Gallen surgeon. Complete pre- and perioperative data, including 3-month surgical RARP outcomes, were prospectively documented. For statistical analysis, Wilcoxon, exact Poisson and χ(2) tests were used. During the first year, the two hospitals (61 RARP patients in Lucerne, 19 RARP patients in St. Gallen) did not differ significantly in preoperative, perioperative or oncological and functional results except for prostate volume (median 33 [interquartile range 24-40] vs. 40 [interquartile range 33-57] ml; p = 0.02), operation time (mean 252 ± 49 vs. 351 ± 50 min; p = 0.0001), number of lymph nodes removed (median 16 [interquartile range 13-21] vs. 15 [interquartile range 8-16] nodes; p = 0.02), biopsy (p = 0.04) and specimen Gleason scores (p = 0.03), and length of hospital stay (median 8 [interquartile range 7-14] vs. 9 [interquartile range 8-18] days; p < 0.01). Da Vinci® device sharing with transfer of surgical know-how can reduce the costs of RARP without compromising surgical outcomes, even at the beginning of the learning curve. © 2014 S. Karger AG, Basel.

  8. A software-based tool for video motion tracking in the surgical skills assessment landscape

    NARCIS (Netherlands)

    Ganni, S.; Botden, Sanne M.B.I.; Chmarra, M.K.; Goossens, R.H.M.; Jakimowicz, J.J.

    2018-01-01

    Background: The use of motion tracking has been proved to provide an objective assessment in surgical skills training. Current systems, however, require the use of additional equipment or specialised laparoscopic instruments and cameras to extract the data. The aim of this study was to determine

  9. Systems for tracking minimally invasive surgical instruments

    NARCIS (Netherlands)

    Chmarra, M. K.; Grimbergen, C. A.; Dankelman, J.

    2007-01-01

    Minimally invasive surgery (e.g. laparoscopy) requires special surgical skills, which should be objectively assessed. Several studies have shown that motion analysis is a valuable assessment tool of basic surgical skills in laparoscopy. However, to use motion analysis as the assessment tool, it is

  10. Validation of a community-based survey assessing non-obstetric surgical conditions in Burera District, Rwanda.

    Science.gov (United States)

    Linden, Allison F; Maine, Rebecca; Hedt-Gauthier, Bethany L; Kamanzi, Emmanual; Mody, Gita; Ntakiyiruta, Georges; Kansayisa, Grace; Ntaganda, Edmond; Niyonkuru, Francine; Mubiligi, Joel; Mpunga, Tharcisse; Meara, John G; Riviello, Robert

    2015-04-27

    Community-based surveillance methods to monitor epidemiological progress in surgery have not yet been employed for surgical capacity building. The aim of this study was to create and assess the validity of a questionnaire that collected data for untreated surgically correctable diseases throughout Burera District, northern Rwanda, to accurately plan for surgical services. A structured interview to assess for the presence or absence of ten index surgically treatable conditions (breast mass, cleft lip/palate, club foot, hernia or hydrocele [adult and paediatric]), hydrocephalus, hypospadias, injuries or wounds, neck mass, undescended testes, and vaginal fistula) was created. The interview was built based on previously validated questionnaires, forward and back translated into the local language and underwent focus group augmentation and pilot testing. In March and May, 2012, data collectors conducted the structured interviews with a household representative in 30 villages throughout Burera District, selected using a two-stage cluster sampling design. Rwandan physicians revisited the surveyed households to perform physical examinations on all household members, used as the gold standard to validate the structured interview. Ethical approval was obtained from Boston Children's Hospital (Boston, MA, USA) and the Rwandan National Ethics Committee (Kigali, Rwanda). Informed consent was obtained from all households. 2990 individuals were surveyed, a 97% response rate. 2094 (70%) individuals were available for physical examination. The calculated overall sensitivity of the structured interview tool was 44·5% (95% CI 38·9-50·2) and the specificity was 97·7% (96·9-98·3%; appendix). The positive predictive value was 70% (95% CI 60·5-73·5), whereas the negative predictive value was 91·3% (90·0-92·5). The conditions with the highest sensitivity and specificity, respectively, were hydrocephalus (100% and 100%), clubfoot (100% and 99·8%), injuries or wounds (54·7% and

  11. Condition-specific Quality of Life Assessment at Each Stage of Class III Surgical Orthodontic Treatment -A Prospective Study.

    Science.gov (United States)

    Tachiki, Chie; Nishii, Yasushi; Takaki, Takashi; Sueishi, Kenji

    2018-01-01

    Surgical orthodontic treatment has been reported to improve oral health-related quality of life (OHRQL). Such treatment comprises three stages: pre-surgical orthodontic treatment; orthognathic surgery; and post-surgical orthodontic treatment. Most studies have focused on change in OHRQL between before and after surgery. However, it is also necessary to evaluate OHRQL at the pre-surgical orthodontic treatment stage, as it may be negatively affected by dental decompensation compared with at pre-treatment. The purpose of this prospective study was to investigate the influence of surgical orthodontic treatment on QOL by assessing change in condition-specific QOL at each stage of treatment in skeletal class III cases. Twenty skeletal class III patients requiring surgical orthodontic treatment were enrolled in the study. Each patient completed the Orthognathic Quality of Life Questionnaire (OQLQ), which was developed for patients with dentofacial deformity. Its items are grouped into 4 domains: "social aspects of dentofacial deformity"; "facial esthetics"; "oral function"; and "awareness of dentofacial esthetics". The questionnaire was completed at the pre-treatment, pre-surgical orthodontic treatment, and post-surgical orthodontic treatment stages. The results revealed a significant worsening in scores between at pre-treatment and pre-surgical orthodontic treatment in the domains of facial esthetics and oral function (ppre-surgical orthodontic and post-surgical orthodontic treatment in all domains except awareness of dentofacial esthetics (ppre-surgical orthodontic treatment stage. Significant correlations were also observed between improvement in upper and lower lip difference, soft tissue pogonion protrusion, and ANB angle and improvement in OQLQ scores at the post-surgical orthodontic treatment stage. These results indicate that morphologic change influences OHRQL in patients undergoing surgical orthodontic treatment not only after surgery, but also during pre-surgical

  12. A proposed protocol for remote control of automated assessment devices

    International Nuclear Information System (INIS)

    Kissock, P.S.; Pritchard, D.A.

    1996-01-01

    Systems and devices that are controlled remotely are becoming more common in security systems in the US Air Force and other government agencies to provide protection of valuable assets. These systems reduce the number of needed personnel while still providing a high level of protection. However, each remotely controlled device usually has its own communication protocol. This limits the ability to change devices without changing the system that provides the communications control to the device. Sandia is pursuing a standard protocol that can be used to communicate with the different devices currently in use, or may be used in the future, in the US Air Force and other government agencies throughout the security community. Devices to be controlled include intelligent pan/tilt mounts, day/night video cameras, thermal imaging cameras, and remote data processors. Important features of this protocol include the ability to send messages of varying length, identify the sender, and more importantly, control remote data processors. This paper describes the proposed public domain protocol, features, and examples of use. The authors hope to elicit comments from security technology developers regarding format and use of remotely controlled automated assessment devices

  13. Surgical versus non-surgical management for pleural empyema.

    Science.gov (United States)

    Redden, Mark D; Chin, Tze Yang; van Driel, Mieke L

    2017-03-17

    Empyema refers to pus in the pleural space, commonly due to adjacent pneumonia, chest wall injury, or a complication of thoracic surgery. A range of therapeutic options are available for its management, ranging from percutaneous aspiration and intercostal drainage to video-assisted thoracoscopic surgery (VATS) or thoracotomy drainage. Intrapleural fibrinolytics may also be administered following intercostal drain insertion to facilitate pleural drainage. There is currently a lack of consensus regarding optimal treatment. To assess the effectiveness and safety of surgical versus non-surgical treatments for complicated parapneumonic effusion or pleural empyema. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (2016, Issue 9), MEDLINE (Ebscohost) (1946 to July week 3 2013, July 2015 to October 2016) and MEDLINE (Ovid) (1 May 2013 to July week 1 2015), Embase (2010 to October 2016), CINAHL (1981 to October 2016) and LILACS (1982 to October 2016) on 20 October 2016. We searched ClinicalTrials.gov and WHO International Clinical Trials Registry Platform for ongoing studies (December 2016). Randomised controlled trials that compared a surgical with a non-surgical method of management for all age groups with pleural empyema. Two review authors independently assessed trials for inclusion and risk of bias, extracted data, and checked the data for accuracy. We contacted trial authors for additional information. We assessed the quality of the evidence using the GRADE approach. We included eight randomised controlled trials with a total of 391 participants. Six trials focused on children and two on adults. Trials compared tube thoracostomy drainage (non-surgical), with or without intrapleural fibrinolytics, to either VATS or thoracotomy (surgical) for the management of pleural empyema. Assessment of risk of bias for the included studies was generally unclear for selection and blinding but low for attrition and reporting bias. Data analyses compared

  14. Assessment of surgical competence in North American graduate periodontics programs: a survey of current practices.

    Science.gov (United States)

    Ghiabi, Edmond; Taylor, K Lynn

    2010-08-01

    This cross-sectional study was designed to document the methods utilized by North American graduate periodontics programs in assessing their residents' surgical skills. A survey of clinical skills assessment was mailed to directors of all fifty-eight graduate periodontics programs in Canada and the United States. Thirty-four programs (59 percent) responded. The data collected were analyzed using SPSS version 15.0. The results demonstrate that the most common practice for providing feedback and documenting residents' surgical skills in the programs surveyed was daily one-on-one verbal feedback given by an instructor. The next two most commonly reported methods were a standard checklist developed at program level and a combination of a checklist and verbal comments. The majority of the programs reported that the instructors met collectively once per term to evaluate the residents' progress. The results suggest that graduate periodontics programs provide their residents frequent opportunities for daily practice with verbal feedback from instructors. However, assessment strategies identified in other health professions as beneficial in fostering the integration of clinical skills practices are not employed.

  15. Unconventional uses of septal occluder devices: Our experience reviewed

    Directory of Open Access Journals (Sweden)

    Neeraj Awasthy

    2015-03-01

    Conclusion: It is feasible in selected nonseptal defects, which traditionally have been subjected to surgical interventions, to treat successfully, non surgically with the use of non prototype occluder devices without significant complications. Conventionally these devices have not been recommended for closure of nonseptal defects but show good early outcome. Adequate sample size with good follow up data is necessary before concluding that it can be safe alternative to surgery on long term.

  16. Teamwork Assessment Tools in Modern Surgical Practice: A Systematic Review

    Science.gov (United States)

    Whittaker, George; Abboudi, Hamid; Khan, Muhammed Shamim; Dasgupta, Prokar; Ahmed, Kamran

    2015-01-01

    Introduction. Deficiencies in teamwork skills have been shown to contribute to the occurrence of adverse events during surgery. Consequently, several teamwork assessment tools have been developed to evaluate trainee nontechnical performance. This paper aims to provide an overview of these instruments and review the validity of each tool. Furthermore, the present paper aims to review the deficiencies surrounding training and propose several recommendations to address these issues. Methods. A systematic literature search was conducted to identify teamwork assessment tools using MEDLINE (1946 to August 2015), EMBASE (1974 to August 2015), and PsycINFO (1806 to August 2015) databases. Results. Eight assessment tools which encompass aspects of teamwork were identified. The Nontechnical Skills for Surgeons (NOTSS) assessment was found to possess the highest level of validity from a variety of sources; reliability and acceptability have also been established for this tool. Conclusions. Deficits in current surgical training pathways have prompted several recommendations to meet the evolving requirements of surgeons. Recommendations from the current paper include integration of teamwork training and assessment into medical school curricula, standardised formal training of assessors to ensure accurate evaluation of nontechnical skill acquisition, and integration of concurrent technical and nontechnical skills training throughout training. PMID:26425732

  17. Assessing the surgical skills of trainees in the operating theatre: a prospective observational study of the methodology.

    Science.gov (United States)

    Beard, J D; Marriott, J; Purdie, H; Crossley, J

    2011-01-01

    To compare user satisfaction and acceptability, reliability and validity of three different methods of assessing the surgical skills of trainees by direct observation in the operating theatre across a range of different surgical specialties and index procedures. A 2-year prospective, observational study in the operating theatres of three teaching hospitals in Sheffield. The assessment methods were procedure-based assessment (PBA), Objective Structured Assessment of Technical Skills (OSATS) and Non-technical Skills for Surgeons (NOTSS). The specialties were obstetrics and gynaecology (O&G) and upper gastrointestinal, colorectal, cardiac, vascular and orthopaedic surgery. Two to four typical index procedures were selected from each specialty. Surgical trainees were directly observed performing typical index procedures and assessed using a combination of two of the three methods (OSATS or PBA and NOTSS for O&G, PBA and NOTSS for the other specialties) by the consultant clinical supervisor for the case and the anaesthetist and/or scrub nurse, as well as one or more independent assessors from the research team. Information on user satisfaction and acceptability of each assessment method from both assessor and trainee perspectives was obtained from structured questionnaires. The reliability of each method was measured using generalisability theory. Aspects of validity included the internal structure of each tool and correlation between tools, construct validity, predictive validity, interprocedural differences, the effect of assessor designation and the effect of assessment on performance. Of the 558 patients who were consented, a total of 437 (78%) cases were included in the study: 51 consultant clinical supervisors, 56 anaesthetists, 39 nurses, 2 surgical care practitioners and 4 independent assessors provided 1635 assessments on 85 trainees undertaking the 437 cases. A total of 749 PBAs, 695 NOTSS and 191 OSATSs were performed. Non-O&G clinical supervisors and

  18. Postoperative assessment of surgical results using three dimensional surface reconstruction CT (3D-CT) in a craniofacial anomaly

    International Nuclear Information System (INIS)

    Nishimura, Jiro; Sato, Kaoru; Nishimoto, Hiroshi; Tsukiyama, Takashi; Fujioka, Mutsuhisa; Akagawa, Tetsuya.

    1988-01-01

    In 1983, Michael W. Vannier and Jeffrey L. Marsh developed a computer method that reconstructs three dimensional (3D) born and soft tissue surfaces, given a high resolution CT scan-series of the facial skeleton. This method has been applied to craniofacial anomalies, basal encephaloceles, and musculoskeletal anomalies. In this study, a postoperative assessment of the craniofacial surgical results has been accomplished using this 3D-CT in 2 children with craniofacial dysmorphism. The authors discuss the advantages of this 3D-CT imaging method in the postoperative assessments of craniofacial anomalies. Results are detailed in the following listing : 1) a postoperative 3D-CT reveals the anatomical details corrected by the craniofacial surgery more precisely and stereographically than conventional radiological methods ; 2) secondary changes of the cranium after the surgery, such as bony formation in the area of the osteotomy and postoperative asymmetric deformities, are detected early by the 3D-CT imaging technique, and, 3) 3D-CT mid-sagittal and top axial views of the intracranial skull base are most useful in postoperative assessments of the surgical results. Basesd on our experience, we expect that three dimensional surface reconstructions from CT scans will become to be used widely in the postoperative assessments of the surgical results of craniofacial anomalies. (author)

  19. Simulators and virtual reality in surgical education.

    Science.gov (United States)

    Chou, Betty; Handa, Victoria L

    2006-06-01

    This article explores the pros and cons of virtual reality simulators, their abilities to train and assess surgical skills, and their potential future applications. Computer-based virtual reality simulators and more conventional box trainers are compared and contrasted. The virtual reality simulator provides objective assessment of surgical skills and immediate feedback further to enhance training. With this ability to provide standardized, unbiased assessment of surgical skills, the virtual reality trainer has the potential to be a tool for selecting, instructing, certifying, and recertifying gynecologists.

  20. Surgical wound dehiscence: a conceptual framework for patient assessment.

    Science.gov (United States)

    Sandy-Hodgetts, Kylie; Carville, Keryln; Leslie, Gavin D

    2018-03-02

    This paper presents a conceptual framework which outlines the risk factors associated with surgical wound dehiscence (SWD) as identified in the literature. The purpose for the development of the conceptual framework was to derive an evidence-based, informed understanding of factors associated with SWD, in order to inform a programme of research on the aetiology and potential risk factors of SWD. Incorporated within the patient-centric conceptual framework are patient related comorbidities, intraoperative and postoperative risk factors related to SWD. These are categorised as either 'mechanical' or 'physiological mechanisms' posited to influence these relationships. The use of the conceptual model for assessment of patients has particular clinical relevance for identification of risk and the management of patients in the pre-, intra- and postoperative period.

  1. The Importance of Registries in the Postmarketing Surveillance of Surgical Meshes.

    Science.gov (United States)

    Köckerling, Ferdinand; Simon, Thomas; Hukauf, Martin; Hellinger, Achim; Fortelny, Rene; Reinpold, Wolfgang; Bittner, Reinhard

    2017-06-07

    To assess the role of registries in the postmarketing surveillance of surgical meshes. To date, surgical meshes are classified as group II medical devices. Class II devices do not require premarket clearance by clinical studies. Ethicon initiated a voluntary market withdrawal of Physiomesh for laparoscopic use after an analysis of unpublished data from the 2 large independent hernia registries-Herniamed German Registry and Danish Hernia Database. This paper now presents the relevant data from the Herniamed Registry. The present analysis compares the prospective perioperative and 1-year follow-up data collected for all patients with incisional hernia who had undergone elective laparoscopic intraperitoneal onlay mesh repair either with Physiomesh (n = 1380) or with other meshes recommended in the guidelines (n = 3834). Patients with Physiomesh repair had a markedly higher recurrence rate compared with the other recommended meshes (12.0% vs 5.0%; P manufacturing company must be taken into account.This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0.

  2. Development of haptic system for surgical robot

    Science.gov (United States)

    Gang, Han Gyeol; Park, Jiong Min; Choi, Seung-Bok; Sohn, Jung Woo

    2017-04-01

    In this paper, a new type of haptic system for surgical robot application is proposed and its performances are evaluated experimentally. The proposed haptic system consists of an effective master device and a precision slave robot. The master device has 3-DOF rotational motion as same as human wrist motion. It has lightweight structure with a gyro sensor and three small-sized MR brakes for position measurement and repulsive torque generation, respectively. The slave robot has 3-DOF rotational motion using servomotors, five bar linkage and a torque sensor is used to measure resistive torque. It has been experimentally demonstrated that the proposed haptic system has good performances on tracking control of desired position and repulsive torque. It can be concluded that the proposed haptic system can be effectively applied to the surgical robot system in real field.

  3. Ahmed glaucoma valve implant: surgical technique and complications

    Directory of Open Access Journals (Sweden)

    Riva I

    2017-02-01

    Full Text Available Ivano Riva,1 Gloria Roberti,1 Francesco Oddone,1 Anastasios GP Konstas,2 Luciano Quaranta3 1IRCCS “Fondazione GB Bietti per l’Oftalmologia”, Rome, Italy; 21st University Department of Ophthalmology, Glaucoma Unit, AHEPA Hospital, Thessaloniki, Greece; 3Department of Medical and Surgical Specialties, Section of Ophthalmology, University of Brescia, Brescia, Italy Abstract: Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications. Keywords: glaucoma, surgical technique, glaucoma drainage devices, Ahmed glaucoma valve, complications

  4. Assessing fistula and obstetrical surgical capacity in South Kivu, DRC

    Directory of Open Access Journals (Sweden)

    Stephen C. Morris

    2013-01-01

    Full Text Available The Democratic Republic of Congo has suffered from decades of conflict and poverty. The Eastern DRC, in particular, continues to be a region dominated by instability, resulting in a fragmented health system. Governments and agencies interested in working towards improving health in the region are often challenged by an absence of knowledge of health metrics, limited capacity for health care delivery and overwhelming needs. The Harvard Humanitarian Initiative and Engender Health needs assessment, outlined in this report, demonstrates an effort to better understand the current state of surgical capacity in the region with an emphasis on needs and opportunities related to fistula repair.

  5. Hysteroscopic sterilization of patient with intrauterine device Mirena®

    Science.gov (United States)

    Depes, Daniella De Batista; Pereira, Ana Maria Gomes; Yatabe, Salete; Lopes, Reginaldo Guedes Coelho

    2013-01-01

    ABSTRACT Tubal sterilization is the definitive procedure most often used worldwide to control fecundity. Laparoscopic ligature is safe, but invasive and with possible surgical and anesthetic risks. The hysteroscopic approach enables tubal occlusion at outpatient's setting without the need of incisions or anesthesia. A microdevice (Essure®) is inserted directly into the tubes and its polyethelene fibers cause obstruction of tubes in about three months. During this period, it is recommended that patients continue the use of a temporary birth control method. Several women use the levonorgestrel-releasing intrauterine system, which is called in the market as Mirena®. This report evaluated the possibility of inserting Essure® without remove the intrauterine device; patient tolerance to the procedure was also assessed. The tubal device was successfully placed in the patient without the need to remove Mirena®. After three months the intrauterine device was removed with no intercurrent events. PMID:23579753

  6. Surgical construction of a novel simulated carotid siphon in canines

    International Nuclear Information System (INIS)

    Tan Huaqiao; Li Minghua; Zhu Yueqi; Fang Chun; Wang Jue; Wu Chungen; Cheng Yingsheng; Xie Jian; Zhang He

    2008-01-01

    Objective: To develop in vivo carotid siphon models by surgical method using the shaped devices for testing the performance of covered stent specially designed for intracranial vascular diseases. Methods: Six carotid siphon-shaped devices were established using stereolithographic biomodeling and the lost-wax technique. Six canines underwent surgery to expose and isolate bilateral CCA. The right CCA origin was ligated and incised distal to the ligation point after the distal right CCA was temporarily closed. The distal left CCA was ligated and incised proximal to the ligation point after the left CCA origin was closed. The proximal isolated left CCA was passed through the shaped device. The distal isolated right CCA and the proximal isolated left CCA were anastomosed end-to-end. Finally, the shaped device of carotid siphon was fixed with suture and embedded in the left neck. The intraarterial DSA was performed on postprocedural 7 days, 2 weeks and 1 month. The morphological characteristics of carotid siphon models were visually evaluated by two observers. The patency of siphon model and the stenosis of anastomotic stoma were followed-up. Results: All animals tolerated the surgical procedure well with mean model time construction of 90 minutes. The morphological characteristics of siphon models were similar to those in human. The anastomotic stoma stenosis occurred in 2 siphon models, and thrombosis of anastomotic stoma in 1, but all siphons of these models were patent on post-procedural follow-up angiography. Conclusion: Surgical construction of an in vivo carotid siphon model of canine with shaped device is practically feasible. This model can be used for testing neurovascular devices. (authors)

  7. Assessment of psychomotor skills acquisition during laparoscopic cholecystectomy courses.

    Science.gov (United States)

    Hance, Julian; Aggarwal, Rajesh; Moorthy, Krishna; Munz, Yaron; Undre, Shabnam; Darzi, Ara

    2005-09-01

    Standardized short courses in laparoscopic cholecystectomy aim to teach laparoscopic skills to surgical trainees, although end-of-course assessments of performance remain subjective. The current study aims to objectively assess psychomotor skills acquisition of trainees attending laparoscopic cholecystectomy courses. Thirty-seven junior surgical trainees had their laparoscopic skills assessed before and after attending 1 of 3 separate 2-day courses (A, B, and C), all with identical format. Assessments were comprised of a standardized simulated laparoscopic task, with performance measured using a valid electromagnetic hand-motion tracking device. Overall, trainees made significant improvements in path length (P=.006), number of movements (Ppsychomotor skills on courses. In addition to providing participants with an insight into their skills, these data can be used to demonstrate course efficacy.

  8. Prospective randomized assessment of single versus double-gloving for general surgical procedures.

    Science.gov (United States)

    Na'aya, H U; Madziga, A G; Eni, U E

    2009-01-01

    There is increased tendency towards double-gloving by general surgeons in our practice, due probably to awareness of the risk of contamination with blood or other body fluids during surgery. The aim of the study was to compare the relative frequency of glove puncture in single-glove versus double glove sets in general surgical procedures, and to determine if duration of surgery affects perforation rate. Surgeons at random do single or double gloves at their discretion, for general surgical procedures. All the gloves used by the surgeons were assessed immediately after surgery for perforation. A total of 1120 gloves were tested, of which 880 were double-glove sets and 240 single-glove sets. There was no significant difference in the overall perforation rate between single and double glove sets (18.3% versus 20%). However, only 2.3% had perforations in both the outer and inner gloves in the double glove group. Therefore, there was significantly greater risk for blood-skin exposure in the single glove sets (p < 0.01). The perforation rate was also significantly greater during procedures lasting an hour or more compared to those lasting less than an hour (p < 0.01). Double-gloving reduces the risk of blood-skin contamination in all general surgical procedures, and especially so in procedures lasting an hour or more.

  9. A Patient-Assessed Morbidity to Evaluate Outcome in Surgically Treated Vestibular Schwannomas.

    Science.gov (United States)

    Al-Shudifat, Abdul Rahman; Kahlon, Babar; Höglund, Peter; Lindberg, Sven; Magnusson, Måns; Siesjo, Peter

    2016-10-01

    Outcome after treatment of vestibular schwannomas can be evaluated by health providers as mortality, recurrence, performance, and morbidity. Because mortality and recurrence are rare events, evaluation has to focus on performance and morbidity. The latter has mostly been reported by health providers. In the present study, we validate 2 new scales for patient-assessed performance and morbidity in comparison with different outcome tools, such as quality of life (QOL) (European Quality of Life-5 dimensions [EQ-5D]), facial nerve score, and work capacity. There were 167 total patients in a retrospective (n = 90) and prospective (n = 50) cohort of surgically treated vestibular schwannomas. A new patient-assessed morbidity score (paMS), a patient-assessed Karnofsky score (paKPS), the patient-assessed QOL (EQ-5D) score, work capacity, and the House-Brackmann facial nerve score were used as outcome measures. Analysis of paMS components and their relation to other outcomes was done as uni- and multivariate analysis. All outcome instruments, except EQ-5D and paKPS, showed a significant decrease postoperatively. Only the facial nerve score (House-Brackmann facial nerve score) differed significantly between the retrospective and prospective cohorts. Out of the 16 components of the paMS, hearing dysfunction, tear dysfunction, balance dysfunction, and eye irritation were most often reported. Both paMS and EQ-5D correlated significantly with work capacity. Standard QOL and performance instruments may not be sufficiently sensitive or specific to measure outcome at the cohort level after surgical treatment of vestibular schwannomas. A morbidity score may yield more detailed information on symptoms that can be relevant for rehabilitation and occupational training after surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Output control of da Vinci surgical system's surgical graspers.

    Science.gov (United States)

    Johnson, Paul J; Schmidt, David E; Duvvuri, Umamaheswar

    2014-01-01

    The number of robot-assisted surgeries performed with the da Vinci surgical system has increased significantly over the past decade. The articulating movements of the robotic surgical grasper are controlled by grip controls at the master console. The user interface has been implicated as one contributing factor in surgical grasping errors. The goal of our study was to characterize and evaluate the user interface of the da Vinci surgical system in controlling surgical graspers. An angular manipulator with force sensors was used to increment the grip control angle as grasper output angles were measured. Input force at the grip control was simultaneously measured throughout the range of motion. Pressure film was used to assess the maximum grasping force achievable with the endoscopic grasping tool. The da Vinci robot's grip control angular input has a nonproportional relationship with the grasper instrument output. The grip control mechanism presents an intrinsic resistant force to the surgeon's fingertips and provides no haptic feedback. The da Vinci Maryland graspers are capable of applying up to 5.1 MPa of local pressure. The angular and force input at the grip control of the da Vinci robot's surgical graspers is nonproportional to the grasper instrument's output. Understanding the true relationship of the grip control input to grasper instrument output may help surgeons understand how to better control the surgical graspers and promote fewer grasping errors. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Creation and Global Deployment of a Mobile, Application-Based Cognitive Simulator for Cardiac Surgical Procedures.

    Science.gov (United States)

    Brewer, Zachary E; Ogden, William David; Fann, James I; Burdon, Thomas A; Sheikh, Ahmad Y

    Several modern learning frameworks (eg, cognitive apprenticeship, anchored instruction, and situated cognition) posit the utility of nontraditional methods for effective experiential learning. Thus, development of novel educational tools emphasizing the cognitive framework of operative sequences may be of benefit to surgical trainees. We propose the development and global deployment of an effective, mobile cognitive cardiac surgical simulator. In methods, 16 preclinical medical students were assessed. Overall, 4 separate surgical modules (sternotomy, cannulation, decannulation, and sternal closure) were created utilizing the Touch Surgery (London, UK) platform. Modules were made available to download free of charge for use on mobile devices. Usage data were collected over a 6-month period. Educational efficacy of the modules was evaluated by randomizing a cohort of medical students to either module usage or traditional, reading-based self-study, followed by a multiple-choice learning assessment tool. In results, downloads of the simulator achieved global penetrance, with highest usage in the USA, Brazil, Italy, UK, and India. Overall, 5368 unique users conducted a total of 1971 hours of simulation. Evaluation of the medical student cohort revealed significantly higher assessment scores in those randomized to module use versus traditional reading (75% ± 9% vs 61% ± 7%, respectively; P < 0.05). In conclusion, this study represents the first effort to create a mobile, interactive cognitive simulator for cardiac surgery. Simulators of this type may be effective for the training and assessment of surgical students. We investigated whether an interactive, mobile-computing-based cognitive task simulator for cardiac surgery could be developed, deployed, and validated. Our findings suggest that such simulators may be a useful learning tool. Copyright © 2016. Published by Elsevier Inc.

  12. Portable Integrated Wireless Device Threat Assessment to Aircraft Radio Systems

    Science.gov (United States)

    Salud, Maria Theresa P.; Williams, Reuben A. (Technical Monitor)

    2004-01-01

    An assessment was conducted on multiple wireless local area network (WLAN) devices using the three wireless standards for spurious radiated emissions to determine their threat to aircraft radio navigation systems. The measurement process, data and analysis are provided for devices tested using IEEE 802.11a, IEEE 802.11b, and Bluetooth as well as data from portable laptops/tablet PCs and PDAs (grouping known as PEDs). A comparison was made between wireless LAN devices and portable electronic devices. Spurious radiated emissions were investigated in the radio frequency bands for the following aircraft systems: Instrument Landing System Localizer and Glideslope, Very High Frequency (VHF) Communication, VHF Omnidirectional Range, Traffic Collision Avoidance System, Air Traffic Control Radar Beacon System, Microwave Landing System and Global Positioning System. Since several of the contiguous navigation systems were grouped under one encompassing measurement frequency band, there were five measurement frequency bands where spurious radiated emissions data were collected for the PEDs and WLAN devices. The report also provides a comparison between emissions data and regulatory emission limit.

  13. Advanced surgical skills for exposure in trauma: a new surgical skills cadaver course for surgery residents and fellows.

    Science.gov (United States)

    Kuhls, Deborah A; Risucci, Donald A; Bowyer, Mark W; Luchette, Fred A

    2013-02-01

    Surgical education is changing owing to workforce and economic demands. Simulation and other technical teaching methods are used to acquire skills transferable to the operating room. Operative management of traumatic injuries has declined, making it difficult to acquire and maintain competence. The ASSET course was developed by the Committee on Trauma's Surgical Skills Committee to fill a surgical skills need in resident and fellow education. Using a human cadaver, standardized rapid exposure of vital structures in the extremities, neck, thorax, abdomen, retroperitoneum, and pelvis is taught. A retrospective analysis of 79 participants in four ASSET courses was performed. Operative experience data were collected, and self-efficacy questionnaires (SEQs) were administered before and after the course. Course evaluations and instructor evaluation data were analyzed. Student's and paired samples t tests as well as analysis of variance and Spearman ρ correlation coefficient analysis were performed using α at p ASSET course would teach new surgical techniques and that learner self-assessed ability would improve. Participants included 27 PGY-4, 20 PGY-5, 24 PGY-6 or PGY-7 and PGY-8 at other levels of training. Self-assessed confidence improved in all body regions (p knowledge rated at 4.8 and learning new techniques at 4.72. A standardized cadaver-based surgical exposures course offered to senior surgical residents adds new surgical skills and improves participant self-assessed ability to perform emergent surgical exposure of vital structures.

  14. Comparison of surgical time and IOP spikes with two ophthalmic viscosurgical devices following Visian STAAR (ICL, V4c model insertion in the immediate postoperative period

    Directory of Open Access Journals (Sweden)

    Ganesh S

    2016-01-01

    Full Text Available Sri Ganesh, Sheetal BrarDepartment of Phaco and Refractive Surgeries, Nethradhama Superspeciality Eye Hospital, Bangalore, IndiaPurpose: To compare the effect of two ocular viscosurgical devices (OVDs on intraocular pressure (IOP and surgical time in immediate postoperative period after bilateral implantable collamer lens (using the V4c model implantation.Methods: A total of 20 eligible patients were randomized to receive 2% hydroxypropylmethylcellulose (HPMC in one eye and 1% hyaluronic acid in fellow eye. Time taken for complete removal of OVD and total surgical time were recorded. At the end of surgery, IOP was adjusted between 15 and 20 mmHg in both the eyes.Results: Mean time for complete OVD evacuation and total surgical time were significantly higher in the HPMC group (P=0.00. Four eyes in the HPMC group had IOP spike, requiring treatment. IOP values with noncontact tonometry at 1, 2, 4, 24, and 48 hours were not statistically significant (P>0.05 for both the groups.Conclusion: The study concluded that 1% hyaluronic acid significantly reduces total surgical time, and incidence of acute spikes may be lower compared to 2% HPMC when used for implantable collamer lens (V4c model.Keywords: OVD, hyaluronic acid, ICL, V4c, IOP spikes

  15. Application of magnetic devices in otiatria

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsov, Anatoly A. E-mail: akuz@sky.chph.ras.ru; Yunin, Alexander M.; Savichev, Alexander A.; Kuznetsov, Oleg A. E-mail: oleg@louisiana.edu; Dmitriev, Nikolai S.; Palchun, Victor T

    2001-07-01

    Several implantable prostheses and other devices based on permanent magnets and using magneto-mechanical forces for their operation were developed for treating middle ear diseases and hearing rehabilitation. Methods of surgical application of the devices were developed and in clinical trials more than 85% of 127 patients with different degrees of middle ear system degradation have shown stable improvement.

  16. Application of magnetic devices in otiatria

    International Nuclear Information System (INIS)

    Kuznetsov, Anatoly A.; Yunin, Alexander M.; Savichev, Alexander A.; Kuznetsov, Oleg A.; Dmitriev, Nikolai S.; Palchun, Victor T.

    2001-01-01

    Several implantable prostheses and other devices based on permanent magnets and using magneto-mechanical forces for their operation were developed for treating middle ear diseases and hearing rehabilitation. Methods of surgical application of the devices were developed and in clinical trials more than 85% of 127 patients with different degrees of middle ear system degradation have shown stable improvement

  17. Transcatheter aortic valve replacement in patients with severe aortic stenosis who are at high risk for surgical complications: summary assessment of the California Technology Assessment Forum.

    Science.gov (United States)

    Tice, Jeffrey A; Sellke, Frank W; Schaff, Hartzell V

    2014-08-01

    The California Technology Assessment Forum is dedicated to assessment and public reporting of syntheses of available data on medical technologies. In this assessment, transcatheter aortic valve replacement (TAVR) was evaluated for patients with severe aortic stenosis (AS) who are at high risk for complications. In this assessment, 5 criteria were used: Regulatory approval, sufficient scientific evidence to allow conclusions on effectiveness, evidence that the technology improves net health outcomes, evidence that the technology is as beneficial as established methods, and availability of the technology outside investigational settings. In this assessment, all 5 criteria were judged to have been met. The primary benefit of TAVR is the ability to treat AS in patients who would otherwise be ineligible for surgical aortic valve replacement. It may also be useful for patients at high surgical risk by potentially reducing periprocedural complications and avoiding the morbidity and recovery from undergoing heart surgery. Potential harms include the need for conversion to an open procedure, perioperative death, myocardial infarction, stroke, bleeding, valve embolization, aortic regurgitation, heart block that requires a permanent pacemaker, renal failure, pulmonary failure, and major vascular complications such as cardiac perforation or arterial dissection. Potential long-term harms include death, stroke, valve failure or clotting, and endocarditis. As highlighted at the February 2012 California Technology Assessment Forum meeting, the dispersion of this technology to new centers across the United States must proceed with careful thought given to training and proctoring multidisciplinary teams to become new centers of excellence. TAVR is a potentially lifesaving procedure that may improve quality of life for patients at high risk for surgical AVR. However, attention needs to be paid to appropriate patient selection, their preoperative evaluation, surgical techniques, and

  18. Biomedical engineering principles of modern cochlear implants and recent surgical innovations.

    Science.gov (United States)

    Eshraghi, Adrien A; Gupta, Chhavi; Ozdamar, Ozcan; Balkany, Thomas J; Truy, Eric; Nazarian, Ronen

    2012-11-01

    This review covers the most recent clinical and surgical advances made in the development and application of cochlear implants (CIs). In recent years, dramatic progress has been made in both clinical and basic science aspect of cochlear implantation. Today's modern CI uses multi-channel electrodes with highly miniaturized powerful digital processing chips. This review article describes the function of various components of the modern multi-channel CIs. A selection of the most recent clinical and surgical innovations is presented. This includes the preliminary results with electro-acoustic stimulation or hybrid devices and ongoing basic science research that is focused on the preservation of residual hearing post-implantation. The result of an original device that uses a binaural stimulation mode with a single implanted receiver/stimulator is also presented. The benefit and surgical design of a temporalis pocket technique for the implant's receiver stimulator is discussed. Advances in biomedical engineering and surgical innovations that lead to an increasingly favorable clinical outcome and to an expansion of the indication of CI surgery are presented and discussed. Copyright © 2012 Wiley Periodicals, Inc.

  19. Patient Self-Assessment of Surgical Site Infection is Inaccurate.

    Science.gov (United States)

    Richter, Vered; Cohen, Matan J; Benenson, Shmuel; Almogy, Gideon; Brezis, Mayer

    2017-08-01

    Availability of surgical site infection (SSI) surveillance rates challenges clinicians, healthcare administrators and leaders and the public. The purpose of this report is to demonstrate the consequences patient self-assessment strategies have on SSI reporting rates. We performed SSI surveillance among patients undergoing general surgery procedures, including telephone follow-up 30 days after surgery. Additionally we undertook a separate validation study in which we compared patient self-assessments of SSI with surgeon assessment. Finally, we performed a meta-analysis of similar validation studies of patient self-assessment strategies. There were 22/266 in-hospital SSIs diagnosed (8.3%), and additional 16 cases were detected through the 30-day follow-up. In total, the SSI rate was 16.8% (95% CI 10.1-18.5). In the validation survey, we found patient telephone surveillance to have a sensitivity of 66% (95% CI 40-93%) and a specificity of 90% (95% CI 86-94%). The meta-analysis included five additional studies. The overall sensitivity was 83.3% (95% CI 79-88%), and the overall specificity was 97.4% (95% CI 97-98%). Simulation of the meta-analysis results divulged that when the true infection rate is 1%, reported rates would be 4%; a true rate of 50%, the reported rates would be 43%. Patient self-assessment strategies in order to fulfill 30-day SSI surveillance misestimate SSI rates and lead to an erroneous overall appreciation of inter-institutional variation. Self-assessment strategies overestimate SSIs rate of institutions with high-quality performance and underestimate rates of poor performance. We propose such strategies be abandoned. Alternative strategies of patient follow-up strategies should be evaluated in order to provide valid and reliable information regarding institutional performance in preventing patient harm.

  20. Assessing suturing techniques using a virtual reality surgical simulator.

    Science.gov (United States)

    Kazemi, Hamed; Rappel, James K; Poston, Timothy; Hai Lim, Beng; Burdet, Etienne; Leong Teo, Chee

    2010-09-01

    Advantages of virtual-reality simulators surgical skill assessment and training include more training time, no risk to patient, repeatable difficulty level, reliable feedback, without the resource demands, and ethical issues of animal-based training. We tested this for a key subtask and showed a strong link between skill in the simulator and in reality. Suturing performance was assessed for four groups of participants, including experienced surgeons and naive subjects, on a custom-made virtual-reality simulator. Each subject tried the experiment 30 times using five different types of needles to perform a standardized suture placement task. Traditional metrics of performance as well as new metrics enabled by our system were proposed, and the data indicate difference between trained and untrained performance. In all traditional parameters such as time, number of attempts, and motion quantity, the medical surgeons outperformed the other three groups, though differences were not significant. However, motion smoothness, penetration and exit angles, tear size areas, and orientation change were statistically significant in the trained group when compared with untrained group. This suggests that these parameters can be used in virtual microsurgery training.

  1. Pilot for the Australian Breast Device Registry (ABDR): a national opt-out clinical quality registry for breast device surgery.

    Science.gov (United States)

    Hopper, Ingrid; Best, Renee L; McNeil, John J; Mulvany, Catherine M; Moore, Colin C M; Elder, Elisabeth; Pase, Marie; Cooter, Rodney D; Evans, Sue M

    2017-12-28

    To establish a pilot clinical quality registry (CQR) to monitor the quality of care and device performance for breast device surgery in Australia. All patients having breast device surgery from contributing hospitals in Australia. A literature review was performed which identified quality indicators for breast device surgery. A pilot CQR was established in 2011 to capture prospective data on breast device surgery. An interim Steering Committee and Management Committee were established to provide clinical governance, and guide quality indicator selection. The registry's minimum dataset was formulated in consultation with stakeholder groups; potential quality indicators were assessed in terms of (1) importance and relevance, (2) usability, (3) feasibility to collect and (4) scientific validity. Data collection was by a two-sided paper-based form with manual data entry. Seven sites were recruited, including one public hospital, four private hospitals and two day surgeries. Patients were recruited and opt-out consent used. The pilot breast device registry provides high-quality population-based data. It provides a model for developing a national CQR for breast devices; its minimum dataset and quality indicators reflect the opinions of the broad range of stakeholders. It is easily scalable, and has formed the basis for other international surgical groups establishing similar registries. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. [New medical device hospital assessment: what kind of clinical data?].

    Science.gov (United States)

    Beaussier, H; Junot, H; Lancrenon, S; Faure, P

    2012-01-01

    Since 2003, the AP-HP medical devices committee (CODIMS) assess the therapeutic relevance of innovated medical device (MD) for the French AP-HP hospitals' group. To accomplish this task, the CODIMS asks manufacturers to bring out clinical arguments to justify the use of their MD in hospital. This work analyses retrospectively after 8years, all assessed MD until March 2011 and the scientific quality of the clinical data submitted by manufacturers to the CODIMS to purchase their MD. All MD were classed according to their certification's level (I, IIa, IIb, III, DMIA). The quality of available clinical studies (CS) provided by manufacturers for each case was assessed and classed according to five clinical relevance levels based on the evidence-based medecine standards (1-2: high methodology; 3-5: low methodology). One hundred and three MD files (80 % of class IIb and III MD) were analysed by the CODIMS (630CS). Our results highlight the lack of relevance of files that are provided to assess innovated MD: 29 files without any CS; concerning class IIb (32DMS, 221CS) and III (50, 342CS) MD, only 6 % of CS presented a correct clinical relevance level. And the situation did not get better during this assessment period. The CODIMS deplore the poor clinical relevance of files provided to assess MD (wrong comparator, inappropriate ends-points, insufficient follow-up to assess long-term security, small population studied). Future legislative developments for MD assessment are expected to improve this situation. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  3. Post-surgical enterococcal meningitis: clinical and epidemiological study of 20 cases.

    Science.gov (United States)

    Guardado, Rodríguez; Asensi, V; Torres, J M; Pérez, F; Blanco, A; Maradona, J A; Cartón, J A

    2006-01-01

    Enterococcal post-surgical meningitis is an uncommon disease. 20 episodes of nosocomial post-surgical enterococcal meningitis diagnosed between 1994 and 2003 were retrospectively studied. During the period of study 20 cases of post-surgical enterococcal meningitis (60% female, mean age 55+/-18 y, range 16-78 y) were reviewed. The mean time between admission at the hospital and surgery was 26 (SD = 15) d (range 7-61 d). The most frequent underlying diseases were: intracerebral haemorrhage (55%), brain neoplasms (25%), head trauma (15%) and hydrocephalus (5%). 11 patients had previously received antibiotic treatment. The isolates identified were Enterococcus faecalis (n = 18) (90%), E. faecium (1) and E. durans (1). 11 patients had polymicrobial infections. The treatment most frequently used was vancomycin alone or with other antibiotics (11). In 5 patients intrathecal vancomycin (20 mg/d) was also added. The mortality rate was not different in intrathecally treated patients. Cerebrospinal fluid (CSF) devices were removed in 8 patients. Four patients died due to the infection. Mortality was significantly associated with lack of removal of the CSF devices (p = 0.04). Enterococcal spp. are a cause of nosocomial meningitis associated with neurosurgical procedures and the presence of neurological devices.

  4. Editor's Choice - Arteriotomy Closure Devices in EVAR, TEVAR, and TAVR : A Systematic Review and Meta-analysis of Randomised Clinical Trials and Cohort Studies

    NARCIS (Netherlands)

    Vierhout, B. P.; Pol, R. A.; El Moumni, M.; Zeebregts, C. J.

    Objectives: Cardiac and vascular surgery benefit from percutaneous interventions. Arteriotomy closure devices (ACDs) enable minimally invasive access to the common femoral artery (CFA). The objective of this review was to assess the differences between ACDs and surgical cut down (SCD) of the CFA

  5. Transcatheter Device Closure of Patent Ductus Arteriosus

    International Nuclear Information System (INIS)

    Sultan, M.; Ullah, M.; Sadiq, N.; Akhtar, K.; Akbar, H.

    2014-01-01

    Objective: To determine the efficacy, safety and immediate complications encountered during percutaneous device closure of patent ductus arteriosus (PDA). Study Design: Case series. Place and Duration of Study: Department of Paediatric Cardiology, AFIC/NIHD, Rawalpindi, from January 2005 to December 2010. Methodology: Consecutive 500 patients who underwent attempted transcatheter PDA device closure were included in the study. Device type position, success of closure and complications were described as frequency percentage. Results: In 491 cases (98.2%), PDA was successfully occluded including 4 cases (0.8%) where devices were dislodged but retrieved and redeployed in Cath laboratory. PDA occluder devices used in 448 cases (91%) while coils (single or multiple) were used in 42 cases (8.5%) and in one case (0.2%) ASD occluder device was used to occlude the PDA. There were 09 (1.8%) unsuccessful cases, 06 (1.2%) were abandoned as ducts were considered unsuitable for device closure, 02 (0.4%) devices dislodged and needed surgical retrieval and one case (0.2%) was abandoned due to faulty equipment. The narrowest PDA diameter ranged from 0.5 - 14 mm with mean of 4.5 +- 2.4 mm. There was a single (0.2%) mortality. Conclusion: Transcatheter occlusion of PDA by coil or occluder device is an effective therapeutic option with high success rate. Complication rate is low in the hands of skilled operators yet paediatric cardiac surgical back-up cover is mandatory. (author)

  6. Surgical placement of a wireless telemetry device for cardiovascular studies of bovine calves [version 1; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Joseph M. Neary

    2017-07-01

    Full Text Available Background: Domestic cattle (Bos taurus are naturally susceptible to hypoxia-induced pulmonary arterial hypertension; consequently, the bovine calf has been used with considerable success as an animal model of the analogous human condition. Studies to date, however, have relied on instantaneous measurements of pressure and cardiac output. Here, we describe the surgical technique for placement of a fully implantable wireless biotelemetry device in a bovine calf for measurement of pulmonary arterial and left ventricular pressures, right ventricular output, and electrocardiogram. Methods: Three, 2-month old bovine calves underwent left-sided thoracotomies. A transit-time flow probe was placed around the pulmonary artery and solid-state pressure catheters inserted into the pulmonary artery and left ventricle. Biopotential leads were secured to the epicardium. The implant body was secured subcutaneously, dorso-caudal to the incision. Results: The implant and sensors were successfully placed in two of the three calves. One calf died from ventricular fibrillation following left ventricular puncture prior to pressure sensor insertion. Anatomical discrepancies meant that either 4th or 5th rib was removed. The calves recovered quickly with minimal complications that included moderate dyspnea and subcutaneous edema. Conclusions: Left thoracotomy is a viable surgical approach for wireless biotelemetry studies of bovine calf cardiovascular function. The real-time, contemporaneous collection of cardiovascular pressures and output, permits pathophysiological studies in a naturally susceptible, large animal model of pulmonary arterial hypertension.

  7. What evidence is there for the use of workplace-based assessment in surgical training?

    Science.gov (United States)

    Shalhoub, Joseph; Vesey, Alex Thomas; Fitzgerald, James Edward Frankland

    2014-01-01

    Recent years have seen broad changes in postgraduate training with a move toward structured formative and summative evaluation of trainees' competencies using workplace-based assessment (WBA) tools. The fitness for purpose of these instruments in surgery has been much debated. The aim of this study is to explore the evidence underlying the introduction and ongoing use of WBAs in surgical training. A critical literature review was conducted to identify studies evaluating the use of WBAs in postgraduate surgical training. The search was conducted using the electronic databases PubMed for full-text articles in English. Additional critical evaluations of the curriculum relating to WBAs were included. The articles were synthesized in a narrative review. The implementation of WBA requirements in surgical training has occurred despite a relative dearth of direct evidence of their efficacy and benefit. Studies and critical reviews are being regularly undertaken to ensure that supporting evidence is accrued and the drive for improvement and refinement is maintained. It is emerging that WBAs are (contrary to their current nomenclature) formative tools for feedback and hence learning. They can facilitate the progression toward expert practice at the center of the zone of proximal development and the higher levels of Miller's pyramid, but fall short--owing to their focus on competence--of guiding surgical trainees to the higher levels of Maslow's hierarchy. Limited evidence has potentially undermined the introduction of WBAs in surgical training to date. There are misunderstandings regarding their use as either summative or formative educational tools. These shortcomings are an opportunity for further work in examining WBAs in their current or modified form. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  8. Development and control of a magnetorheological haptic device for robot assisted surgery.

    Science.gov (United States)

    Shokrollahi, Elnaz; Goldenberg, Andrew A; Drake, James M; Eastwood, Kyle W; Kang, Matthew

    2017-07-01

    A prototype magnetorheological (MR) fluid-based actuator has been designed for tele-robotic surgical applications. This device is capable of generating forces up to 47 N, with input currents ranging from 0 to 1.5 A. We begin by outlining the physical design of the device, and then discuss a novel nonlinear model of the device's behavior. The model was developed using the Hammerstein-Wiener (H-W) nonlinear black-box technique and is intended to accurately capture the hysteresis behavior of the MR-fluid. Several experiments were conducted on the device to collect estimation and validation datasets to construct the model and assess its performance. Different estimating functions were used to construct the model, and their effectiveness is assessed based on goodness-of-fit and final-prediction-error measurements. A sigmoid network was found to have a goodness-of-fit of 95%. The model estimate was then used to tune a PID controller. Two control schemes were proposed to eliminate the hysteresis behavior present in the MR fluid device. One method uses a traditional force feedback control loop and the other is based on measuring the magnetic field using a Hall-effect sensor embedded within the device. The Hall-effect sensor scheme was found to be superior in terms of cost, simplicity and real-time control performance compared to the force control strategy.

  9. Performance of GPS-devices for environmental exposure assessment.

    Science.gov (United States)

    Beekhuizen, Johan; Kromhout, Hans; Huss, Anke; Vermeulen, Roel

    2013-01-01

    Integration of individual time-location patterns with spatially resolved exposure maps enables a more accurate estimation of personal exposures to environmental pollutants than using estimates at fixed locations. Current global positioning system (GPS) devices can be used to track an individual's location. However, information on GPS-performance in environmental exposure assessment is largely missing. We therefore performed two studies. First, a commute-study, where the commute of 12 individuals was tracked twice, testing GPS-performance for five transport modes and two wearing modes. Second, an urban-tracking study, where one individual was tracked repeatedly through different areas, focused on the effect of building obstruction on GPS-performance. The median error from the true path for walking was 3.7 m, biking 2.9 m, train 4.8 m, bus 4.9 m, and car 3.3 m. Errors were larger in a high-rise commercial area (median error=7.1 m) compared with a low-rise residential area (median error=2.2 m). Thus, GPS-performance largely depends on the transport mode and urban built-up. Although ~85% of all errors were 50 m. Modern GPS-devices are useful tools for environmental exposure assessment, but large GPS-errors might affect estimates of exposures with high spatial variability.

  10. Orthodontic-orthognathic interventions in orthognathic surgical cases: "Paper surgery" and "model surgery" concepts in surgical orthodontics

    Directory of Open Access Journals (Sweden)

    Narayan H Gandedkar

    2016-01-01

    Full Text Available Thorough planning and execution is the key for successful treatment of dentofacial deformity involving surgical orthodontics. Presurgical planning (paper surgery and model surgery are the most essential prerequisites of orthognathic surgery, and orthodontist is the one who carries out this procedure by evaluating diagnostic aids such as crucial clinical findings and radiographic assessments. However, literature pertaining to step-by-step orthognathic surgical guidelines is limited. Hence, this article makes an attempt to provide an insight and nuances involved in the planning and execution. The diagnostic information revealed from clinical findings and radiographic assessments is integrated in the "paper surgery" to establish "surgical-plan." Furthermore, the "paper surgery" is emulated in "model surgery" such that surgical bite-wafers are created, which aid surgeon to preview the final outcome and make surgical movements that are deemed essential for the desired skeletal and dental outcomes. Skeletal complexities are corrected by performing "paper surgery" and an occlusion is set up during "model surgery" for the fabrication of surgical bite-wafers. Further, orthodontics is carried out for the proper settling and finishing of occlusion. Article describes the nuances involved in the treatment of Class III skeletal deformity individuals treated with orthognathic surgical approach and illustrates orthodontic-orthognathic step-by-step procedures from "treatment planning" to "execution" for successful management of aforementioned dentofacial deformity.

  11. 42 CFR 410.36 - Medical supplies, appliances, and devices: Scope.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Medical supplies, appliances, and devices: Scope... Services § 410.36 Medical supplies, appliances, and devices: Scope. (a) Medicare Part B pays for the following medical supplies, appliances and devices: (1) Surgical dressings, and splints, casts, and other...

  12. [Simulation-based robot-assisted surgical training].

    Science.gov (United States)

    Kolontarev, K B; Govorov, A V; Rasner, P I; Sheptunov, S A; Prilepskaya, E A; Maltsev, E G; Pushkar, D Yu

    2015-12-01

    Since the first use of robotic surgical system in 2000, the robot-assisted technology has gained wide popularity throughout the world. Robot-assisted surgical training is a complex issue that requires significant efforts from students and teacher. During the last two decades, simulation-based training had received active development due to wide-spread occurrence and popularization of laparoscopic and robot-assisted surgical techniques. We performed a systematic review to identify the currently available simulators for robot-assisted surgery. We searched the Medline and Pubmed, English sources of literature data, using the following key words and phrases: "robotics", "robotic surgery", "computer assisted surgery", "simulation", "computer simulation", "virtual reality", "surgical training", and "surgical education". There were identified 565 publications, which meet the key words and phrases; 19 publications were selected for the final analysis. It was established that simulation-based training is the most promising teaching tool that can be used in the training of the next generation robotic surgeons. Today the use of simulators to train surgeons is validated. Price of devices is an obvious barrier for inclusion in the program for training of robotic surgeons, but the lack of this tool will result in a sharp increase in the duration of specialists training.

  13. Assessment of Periodontal Status of Surgically Exposed and Orthodontically Aligned Impacted Maxillary Canines

    OpenAIRE

    Adina Coșarcă; Mariana Păcurar; Cecilia Petrovan; Alina Ormenișan

    2014-01-01

    Aim: The aim of this study was to compare the periodontal status of impacted canines after 5 years following completion of the combined surgical and orthodontic treatment. Materials and methods: We examined 20 labially impacted canines and 20 palatally impacted canines at 5 years after the end of treatment. We assessed the periodontal status of these teeth. Results: Different outcomes were found regarding the probing depth and the amount of keratinized gingiva in the two mentioned groups of t...

  14. Vision Assessment and Prescription of Low Vision Devices

    OpenAIRE

    Keeffe, Jill

    2004-01-01

    Assessment of vision and prescription of low vision devices are part of a comprehensive low vision service. Other components of the service include training the person affected by low vision in use of vision and other senses, mobility, activities of daily living, and support for education, employment or leisure activities. Specialist vision rehabilitation agencies have services to provide access to information (libraries) and activity centres for groups of people with impaired vision.

  15. [Risk assessment and risk control for occupational exposure to chemical toxicants from an isophorone nitrile device].

    Science.gov (United States)

    Wang, Dejun; Fu, Xiaokuan; Kong, Fanling; Sui, Shaofeng; Jiang, Yuanyuan; Du, Yinglin; Zhou, Jingyang

    2014-06-01

    Risk assessment and risk control for occupational exposure to chemical toxicants were performed on an isophorone nitrile device with an annual production of 5,000 tons, based on improved Singaporean semi-quantitative risk assessment method, with consideration of actual situation in China and in the present project. With the use of engineering analysis and identification of occupational hazards in the improved Singaporean semi-quantitative risk assessment method, hazard rating (HR) and risk assessment were performed on chemical toxicants from an isophorone nitrile device with an annual production of 5,000 tons. The chemical toxicants in the isophorone nitrile device were mainly isophorone, hydrocyanic acid, methanol, phosphoric acid, sodium hydroxide, and sodium cyanide; the HR values were mild hazard (2), extreme hazard (5), mild hazard (2), mild hazard (2), moderate hazard (3), and extreme hazard (5), respectively, and the corresponding exposure rating (ER) values were 2.09, 2.72, 2.76, 1.68, 2.0, and 1.59, respectively. The risk of chemical toxicants in this project was assessed according to the formula Risk = [HR×ER](1/2). Hydrocyanic acid was determined as high risk, sodium hydroxide and sodium cyanide as medium risk, and isophorone, methanol, and phosphoric acid as low risk. Priority in handling of risks was determined by risk rating. The table of risk control measure was established for pre-assessment of occupational hazards. With risk assessment in this study, we concluded that the isophorone nitrile device with 5,000 ton annual production was a high-occupational hazard device. This device is a project of extreme occupational hazard. The improved Singaporean semi-quantitative risk assessment method is a scientific and applicable method, and is especially suitable for pre-evaluation of on-site project with no analogy.

  16. Sperm quality assessment via separation and sedimentation in a microfluidic device.

    Science.gov (United States)

    Chen, Chang-Yu; Chiang, Tsun-Chao; Lin, Cheng-Ming; Lin, Shu-Sheng; Jong, De-Shien; Tsai, Vincent F-S; Hsieh, Ju-Ton; Wo, Andrew M

    2013-09-07

    A major reason for infertility is due to male factors, including the quality of spermatozoa, which is a primary factor and often difficult to assess, particularly the total sperm concentration and its motile percentage. This work presents a simple microfluidic device to assess sperm quality by quantifying both total and motile sperm counts. The key design feature of the microfluidic device is two channels separated by a permeative phase-guide structure, where one channel is filled with raw semen and the other with pure buffer. The semen sample was allowed to reach equilibrium in both chambers, whereas non-motile sperms remained in the original channel, and roughly half of the motile sperms would swim across the phase-guide barrier into the buffer channel. Sperms in each channel agglomerated into pellets after centrifugation, with the corresponding area representing total and motile sperm concentrations. Total sperm concentration up to 10(8) sperms per ml and motile percentage in the range of 10-70% were tested, encompassing the cutoff value of 40% stated by World Health Organization standards. Results from patient samples show compact and robust pellets after centrifugation. Comparison of total sperm concentration between the microfluidic device and the Makler chamber reveal they agree within 5% and show strong correlation, with a coefficient of determination of R(2) = 0.97. Motile sperm count between the microfluidic device and the Makler chamber agrees within 5%, with a coefficient of determination of R(2) = 0.84. Comparison of results from the Makler Chamber, sperm quality analyzer, and the microfluidic device revealed that results from the microfluidic device agree well with the Makler chamber. The sperm microfluidic chip analyzes both total and motile sperm concentrations in one spin, is accurate and easy to use, and should enable sperm quality analysis with ease.

  17. No Surgical Innovation Without Evaluation: Evolution and Further Development of the IDEAL Framework and Recommendations.

    Science.gov (United States)

    Hirst, Allison; Philippou, Yiannis; Blazeby, Jane; Campbell, Bruce; Campbell, Marion; Feinberg, Joshua; Rovers, Maroeska; Blencowe, Natalie; Pennell, Christopher; Quinn, Tom; Rogers, Wendy; Cook, Jonathan; Kolias, Angelos G; Agha, Riaz; Dahm, Philipp; Sedrakyan, Art; McCulloch, Peter

    2018-04-24

    To update, clarify, and extend IDEAL concepts and recommendations. New surgical procedures, devices, and other complex interventions need robust evaluation for safety, efficacy, and effectiveness. Unlike new medicines, there is no internationally agreed evaluation pathway for generating and analyzing data throughout the life cycle of surgical innovations. The IDEAL Framework and Recommendations were designed to provide this pathway and they have been used increasingly since their introduction in 2009. Based on a Delphi survey, expert workshop and major discussions during IDEAL conferences held in Oxford (2016) and New York (2017), this article updates and extends the IDEAL Recommendations, identifies areas for future research, and discusses the ethical problems faced by investigators at each IDEAL stage. The IDEAL Framework describes 5 stages of evolution for new surgical therapeutic interventions-Idea, Development, Exploration, Assessment, and Long-term Study. This comprehensive update proposes several modifications. First, a "Pre-IDEAL" stage describing preclinical studies has been added. Second we discuss potential adaptations to expand the scope of IDEAL (originally designed for surgical procedures) to accommodate therapeutic devices, through an IDEAL-D variant. Third, we explicitly recognise the value of comprehensive data collection through registries at all stages in the Framework and fourth, we examine the ethical issues that arise at each stage of IDEAL and underpin the recommendations. The Recommendations for each stage are reviewed, clarified and additional detail added. The intention of this article is to widen the practical use of IDEAL by clarifying the rationale for and practical details of the Recommendations. Additional research based on the experience of implementing these Recommendations is needed to further improve them.

  18. Percutaneous Transcatheter PDA Device Closure in Infancy

    International Nuclear Information System (INIS)

    Ullah, M.; Sultan, M.; Akhtar, K.; Sadiq, N.; Akbar, H.

    2014-01-01

    Objective: To evaluate the results and complications associated with transcatheter closure of patent ductus arteriosus (PDA) in infants. Study Design: Quasi-experimental study. Place and Duration of Study: Paediatric Cardiology Department of Armed Forces Institute of Cardiology / National Institute of Heart Diseases (AFIC/NIHD), Rawalpindi, from December 2010 to June 2012. Methodology: Infants undergoing transcatheter device closure of PDA were included. All patients were evaluated by experienced Paediatric Cardiologists with 2-D echocardiography and Doppler before the procedure. Success of closure and complications were recorded. Results: The age of patients varied from 05 - 12 months and 31 (56.4%) were females. Out of the 55 infants, 3 (5.4%) were not offered device closure after aortogram (two large tubular type ducts and one tiny duct, considered unsuitable for device closure); while in 50 (96.1%) patients out of remaining 52, the duct was successfully closed with transcatheter PDA device or coil. In one infant, device deployment resulted in acquired coarctation, necessitating device retrieval by Snare followed by surgical duct interruption and another patient had non-fatal cardiac arrest during device deployment leading to abandonment of procedure and subsequent successful surgical interruption. Local vascular complications occurred in 12 (21.8%) of cases and all were satisfactorily treated. Conclusion: Transcatheter device closure of PDA in infants was an effective procedure in the majority of cases; however, here were considerable number of local access site vascular complications. (author)

  19. Implementation of surgical quality improvement: auditing tool for surgical site infection prevention practices.

    Science.gov (United States)

    Hechenbleikner, Elizabeth M; Hobson, Deborah B; Bennett, Jennifer L; Wick, Elizabeth C

    2015-01-01

    Surgical site infections are a potentially preventable patient harm. Emerging evidence suggests that the implementation of evidence-based process measures for infection reduction is highly variable. The purpose of this work was to develop an auditing tool to assess compliance with infection-related process measures and establish a system for identifying and addressing defects in measure implementation. This was a retrospective cohort study using electronic medical records. We used the auditing tool to assess compliance with 10 process measures in a sample of colorectal surgery patients with and without postoperative infections at an academic medical center (January 2012 to March 2013). We investigated 59 patients with surgical site infections and 49 patients without surgical site infections. First, overall compliance rates for the 10 process measures were compared between patients with infection vs patients without infection to assess if compliance was lower among patients with surgical site infections. Then, because of the burden of data collection, the tool was used exclusively to evaluate quarterly compliance rates among patients with infection. The results were reviewed, and the key factors contributing to noncompliance were identified and addressed. Ninety percent of process measures had lower compliance rates among patients with infection. Detailed review of infection cases identified many defects that improved following the implementation of system-level changes: correct cefotetan redosing (education of anesthesia personnel), temperature at surgical incision >36.0°C (flags used to identify patients for preoperative warming), and the use of preoperative mechanical bowel preparation with oral antibiotics (laxative solutions and antibiotics distributed in clinic before surgery). Quarterly compliance improved for 80% of process measures by the end of the study period. This study was conducted on a small surgical cohort within a select subspecialty. The

  20. The family assessment device: an update.

    Science.gov (United States)

    Mansfield, Abigail K; Keitner, Gabor I; Dealy, Jennifer

    2015-03-01

    The current study set out to describe family functioning scores of a contemporary community sample, using the Family Assessment Device (FAD), and to compare this to a currently help-seeking sample. The community sample consisted of 151 families who completed the FAD. The help-seeking sample consisted of 46 families who completed the FAD at their first family therapy appointment as part of their standard care at an outpatient family therapy clinic at an urban hospital. Findings suggest that FAD means from the contemporary community sample indicate satisfaction with family functioning, while FAD scores from the help-seeking sample indicate dissatisfaction with family functioning. In addition, the General Functioning scale of the FAD continues to correlate highly with all other FAD scales, except Behavior Control. The cut-off scores for the FAD indicating satisfaction or dissatisfaction by family members with their family functioning continue to be relevant and the FAD continues to be a useful tool to assess family functioning in both clinical and research contexts. © 2014 Family Process Institute.

  1. Surgical treatment of gynecomastia: complications and outcomes.

    Science.gov (United States)

    Li, Chun-Chang; Fu, Ju-Peng; Chang, Shun-Cheng; Chen, Tim-Mo; Chen, Shyi-Gen

    2012-11-01

    Gynecomastia is defined as the benign enlargement of the male breast. Multiple surgical options have been used to improve outcomes. The aim of this study was to analyze the surgical approaches to the treatment of gynecomastia and their outcomes over a 10-year period. All patients undergoing surgical correction of gynecomastia in our department between 2000 and 2010 were included for retrospective evaluation. The data were analyzed for etiology, stage of gynecomastia, surgical technique, complications, risk factors, and revision rate. The surgical result was evaluated with self-assessment questionnaires. A total of 41 patients with 75 operations were included. Techniques included subcutaneous mastectomy alone or with additional ultrasound-assisted liposuction (UAL) and isolated UAL. The surgical revision rate for all patients was 4.8%. The skin-sparing procedure gave good surgical results in grade IIb and grade III gynecomastia with low revision and complication rates. The self-assessment report revealed a good level of overall satisfaction and improvement in self-confidence (average scores 9.4 and 9.2, respectively, on a 10-point scale). The treatment of gynecomastia requires an individualized approach. Subcutaneous mastectomy combined with UAL could be used as the first choice for surgical treatment of grade II and III gynecomastia.

  2. Surgical instrument biocontaminant fluorescence detection in ambient lighting conditions for hospital reprocessing and sterilization department (Conference Presentation)

    Science.gov (United States)

    Baribeau, François; Bubel, Annie; Dumont, Guillaume; Vachon, Carl; Lépine, André; Rochefort, Stéphane; Massicotte, Martin; Buteau-Vaillancourt, Louis; Gallant, Pascal; Mermut, Ozzy

    2017-03-01

    Hospitals currently rely on simple human visual inspection for assessing cleanliness of surgical instruments. Studies showed that surgical site infections are in part attributed to inadequate cleaning of medical devices. Standards groups recognize the need to objectively quantify the amount of residues on surgical instruments and establish guidelines. We developed a portable technology for the detection of contaminants on surgical instruments through fluorescence following cleaning. Weak fluorescence signals are usually detected in the obscurity only with the lighting of the excitation source. The key element of this system is that it works in ambient lighting conditions, a requirement to not disturb the normal workflow of hospital reprocessing facilities. A biocompatible fluorescent dye is added to the detergent and labels the proteins of organic residues. It is resistant to the harsh environment in a washer-disinfector. Two inspection devices have been developed with a 488nm laser as the excitation source: a handheld scanner and a tabletop station using spectral-domain and time-domain ambient light cancellation schemes. The systems are eye safe and equipped with image processing and interfacing software to provide visual or audible warnings to the operator based on a set of adjustable signal thresholds. Micron-scale residues are detected by the system which can also evaluate soil size and mass. Unlike swabbing, it can inspect whole tools in real-time. The technology has been validated in an independent hospital decontamination research laboratory. It also has potential applications in the forensics, agro-food, and space fields. Technical aspects and results will be presented and discussed.

  3. The validity of visual acuity assessment using mobile technology devices in the primary care setting.

    Science.gov (United States)

    O'Neill, Samuel; McAndrew, Darryl J

    2016-04-01

    The assessment of visual acuity is indicated in a number of clinical circumstances. It is commonly conducted through the use of a Snellen wall chart. Mobile technology developments and adoption rates by clinicians may potentially provide more convenient methods of assessing visual acuity. Limited data exist on the validity of these devices and applications. The objective of this study was to evaluate the assessment of distance visual acuity using mobile technology devices against the commonly used 3-metre Snellen chart in a primary care setting. A prospective quantitative comparative study was conducted at a regional medical practice. The visual acuity of 60 participants was assessed on a Snellen wall chart and two mobile technology devices (iPhone, iPad). Visual acuity intervals were converted to logarithm of minimum angle of resolution (logMAR) scores and subjected to intraclass correlation coefficient (ICC) assessment. The results show a high level of general agreement between testing modality (ICC 0.917 with a 95% confidence interval of 0.887-0.940). The high level of agreement of visual acuity results between the Snellen wall chart and both mobile technology devices suggests that clinicians can use this technology with confidence in the primary care setting.

  4. Values of iodine metabolism biomarkers in assessing the iodine nutrition status in surgically treated patients with thyroid disease.

    Science.gov (United States)

    Han, Jian-hua; Wu, Lian; Yu, Song-lin; Fang, Hui-ling; Kamg, Wei-ming; Cheng, Xin-qi; Lu, Jie; Yu, Jian-chun; Qiu, Ling

    2015-04-01

    To assess the clinical application value of iodine metabolism biomarkers in assessing iodine nutrition status in surgically treated patients with thyroid disease. Blood,morning urine and 24-hour urine samples were collected in 31 healthy volunteers and in 30 surgically treated patients with thyroid disease before and after surgery. Iodine concentration was analyzed by inductively coupled plasma mass spectrometry. The iodine metabolism biomarkers including serum iodine (SI), morning urine iodine(UI), morning urine iodine/urine creatinine ratio (UI/UCr), 24-hour urine iodine (24 h UI), and 24-hour urine iodine excretion (24 h UIE) were evaluated in these two groups. In addition, the validation coincidence rate of iodine metabolism biomarkers in healthy volunteers to different reference ranges including World Health Organization, Mayo Clinic, and Quest Diagnostics were calculated. The UI/UCr ratio of pre-operative thyroid disease patients was significantly lower than that of healthy volunteers (P0.05) between these two groups. The SI, UI ,and 24 h UI in postoperative thyroid disease patients were significantly higher than those of the pre-operative patients (all Piodine metabolism biomarkers. The UI/UCr ratio may be used for iodine nutrition evaluation in surgically treated patients with thyroid disease.

  5. Undergraduate basic surgical skills education: impact on attitudes to a career in surgery and surgical skills acquisition.

    Science.gov (United States)

    McAnena, P F; O'Halloran, N; Moloney, B M; Courtney, D; Waldron, R M; Flaherty, G; Kerin, M J

    2018-05-01

    Basic surgical skills modules in medical education are effective in teaching skills and increasing confidence among students approaching surgery. However, these modules are not delivered universally and their effect on the professional development of graduates has not been established. We aimed to assess the impact of a 10-week basic surgical skills module on attitudes and technical skills of first year medical students compared to interns. Eighteen students participated and were assessed using a 4-part questionnaire. Technical skills were assessed by observing students perform a basic interrupted suture, using the objective structured assessment of technical skills (OSATS) tool. Fourteen interns were recruited. Students were more confident in surgical scrubbing (mean score 4.0 vs. 2.86, p = 0.001), and performing a basic suture (4.05 vs. 1.93, p = 0.000), more enthusiastic about assisting with an operation (4.5 vs. 3.0, p = 0.001) and more likely to consider a career in surgery (4.16 vs. 2.28, p = 0.000). Technical skills were greater in the student group (mean score 30.8 vs. 19.6, p = 0.001). Five interns had taken part in surgical skills modules as undergraduates. Their technical skills were significantly higher compared to interns who had not (n = 9) (28.8 vs. 14.5, p = 0.006), and they were more likely to consider a career in surgery (3.6 vs. 1.5, p = 0.036). The introduction of surgical skills teaching to the undergraduate medical curriculum has a positive impact on students' attitudes towards surgery and accelerates basic technical skills development. Consideration should be given to development of a standardised undergraduate core curriculum in basic surgical skills teaching.

  6. Validity of Devices That Assess Body Temperature During Outdoor Exercise in the Heat

    Science.gov (United States)

    Casa, Douglas J; Becker, Shannon M; Ganio, Matthew S; Brown, Christopher M; Yeargin, Susan W; Roti, Melissa W; Siegler, Jason; Blowers, Julie A; Glaviano, Neal R; Huggins, Robert A; Armstrong, Lawrence E; Maresh, Carl M

    2007-01-01

    Context: Rectal temperature is recommended by the National Athletic Trainers' Association as the criterion standard for recognizing exertional heat stroke, but other body sites commonly are used to measure temperature. Few authors have assessed the validity of the thermometers that measure body temperature at these sites in athletic settings. Objective: To assess the validity of commonly used temperature devices at various body sites during outdoor exercise in the heat. Design: Observational field study. Setting: Outdoor athletic facilities. Patients or Other Participants: Fifteen men and 10 women (age = 26.5 ± 5.3 years, height = 174.3 ± 11.1 cm, mass = 72.73 ± 15.95 kg, body fat = 16.2 ± 5.5%). Intervention(s): We simultaneously tested inexpensive and expensive devices orally and in the axillary region, along with measures of aural, gastrointestinal, forehead, temporal, and rectal temperatures. Temporal temperature was measured according to the instruction manual and a modified method observed in medical tents at local road races. We also measured forehead temperatures directly on the athletic field (other measures occurred in a covered pavilion) where solar radiation was greater. Rectal temperature was the criterion standard used to assess the validity of all other devices. Subjects' temperatures were measured before exercise, every 60 minutes during 180 minutes of exercise, and every 20 minutes for 60 minutes of postexercise recovery. Temperature devices were considered invalid if the mean bias (average difference between rectal temperature and device temperature) was greater than ±0.27°C (±0.5°F). Main Outcome Measure(s): Temperature from each device at each site and time point. Results: Mean bias for the following temperatures was greater than the allowed limit of ±0.27°C (±0.5°F): temperature obtained via expensive oral device (−1.20°C [−2.17°F]), inexpensive oral device (−1.67°C [−3.00°F]), expensive axillary device (−2.58°C [−4

  7. Intracavitary deposits on Essure® hysteroscopic sterilization devices: A case report.

    Science.gov (United States)

    Maassen, L W; van Gastel, D M; Lentjes, E G W M; Bongers, M Y; Veersema, S

    2017-07-01

    To study the composition of intracavitary deposits on Essure® hysteroscopic sterilization devices. Case report. Reproductive Medicine and Gynecology department of a University Hospital. A 39 years old patient presenting with a request for surgical removal of Essure® sterilization devices. Diagnostic hysteroscopy showed a crystal like white deposit attached to one of the devices. Diagnostic hysteroscopy and surgical removal of Essure® devices was performed. The deposits were collected and infrared spectroscopy analysis was performed. Chemical composition of the deposits attached to the device. Infrared spectroscopy of the material showed patterns conclusive with calcite (calcium carbonate, CaCO 3 ). Until now, it is not clear if there is a relationship between reported complaints and formation of calcite deposits on Essure®. Infrared spectroscopy of deposits on Essure® devices showed a pattern conclusive with calcite. The relationship between reported complaints and the formation of calcite deposits on Essure® remains unclear.

  8. Surgical treatment of tricuspid valve insufficiency promotes early reverse remodeling in patients with axial-flow left ventricular assist devices.

    Science.gov (United States)

    Maltais, Simon; Topilsky, Yan; Tchantchaleishvili, Vakhtang; McKellar, Stephen H; Durham, Lucian A; Joyce, Lyle D; Daly, Richard C; Park, Soon J

    2012-06-01

    The HeartMate II (Thoratec Corp, Pleasanton, Calif) continuous-flow left ventricular assist device has emerged as the standard of care for patients with advanced heart failure. The objective of this study was to assess the safety and early effectiveness of concomitant tricuspid valve procedures in patients undergoing implantation of a HeartMate II device. From February 2007 to April 2010, 83 patients underwent HeartMate II left ventricular assist device implantation. Of these, 37 patients had concomitant tricuspid valve procedures (32 repairs, 5 replacements) for severe tricuspid regurgitation. The effects of a tricuspid valve procedure on tricuspid regurgitation and right ventricular remodeling were assessed comparing echocardiographic findings at baseline and 30 days after left ventricular assist device implantation. Overall survival was also compared. Patients undergoing a concomitant tricuspid valve procedure had more tricuspid regurgitation (vena contracta, 5.6 ± 2.1 mm vs 2.9 ± 2.0 mm; P tricuspid regurgitation was worse in patients who underwent left ventricular assist device implantation alone (+18.6%), whereas it improved significantly in patients undergoing a concomitant tricuspid valve procedure (-50.2%) (P = .005). A corresponding significant reduction in right ventricular end-diastolic area (33.6% ± 6.2% vs 30.1% ± 9.7%; P = .03) and a trend toward better right ventricular function (55.5% ± 79.7% vs 35.7% ± 60.5%; P = .28) were noted in patients undergoing a concomitant tricuspid valve procedure. Survival was comparable between the 2 groups. In patients with severe tricuspid regurgitation undergoing left ventricular assist device implantation, a concomitant tricuspid valve procedure effectively reduces tricuspid regurgitation and promotes reverse remodeling of the right ventricle. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  9. Reviewing the technological challenges associated with the development of a laparoscopic palpation device.

    Science.gov (United States)

    Culmer, Peter; Barrie, Jenifer; Hewson, Rob; Levesley, Martin; Mon-Williams, Mark; Jayne, David; Neville, Anne

    2012-06-01

    Minimally invasive surgery (MIS) has heralded a revolution in surgical practice, with numerous advantages over open surgery. Nevertheless, it prevents the surgeon from directly touching and manipulating tissue and therefore severely restricts the use of valuable techniques such as palpation. Accordingly a key challenge in MIS is to restore haptic feedback to the surgeon. This paper reviews the state-of-the-art in laparoscopic palpation devices (LPDs) with particular focus on device mechanisms, sensors and data analysis. It concludes by examining the challenges that must be overcome to create effective LPD systems that measure and display haptic information to the surgeon for improved intraoperative assessment. Copyright © 2012 John Wiley & Sons, Ltd.

  10. Assessment of carprofen and buprenorphine on recovery of mice after surgical removal of the mammary fat pad.

    Science.gov (United States)

    Adamson, Trinka W; Kendall, Lon V; Goss, Sherri; Grayson, Kevin; Touma, Chadi; Palme, Rupert; Chen, Jane Q; Borowsky, Alexander D

    2010-09-01

    The purpose of this study was to determine the level of pain elicited by mammary fat pad removal surgery and the effects of postoperative analgesics on recovery. Female FVB mice were anesthetized, and mammary fat pad removal was performed. After surgery, mice received carprofen, buprenorphine, a combination of carprofen and buprenorphine, or saline treatment. Additional mice received anesthesia but no surgery or treatment. Food and water intake, body weight, wheel running activity, and a visual assessment score were recorded daily for 4 d after surgery and compared with presurgical findings. Corticosterone metabolites in fecal samples were analyzed at 12 and 24 h postsurgically and compared with baseline values. All surgical groups had significantly decreased food intake at 24 h, with a return to baseline by 48 h. The combination treatment resulted in a significantly decreased water intake and body weight at 24 h. All surgical groups had significantly decreased wheel running activity at 24 h only. The visual assessment scores indicated mild pain for all surgical groups, with the buprenorphine treated mice showing the highest pain index scores, as compared with nonsurgical controls. Fecal corticosterone metabolite levels did not differ significantly between any of the groups or across time. The parameters used in this study did not indicate that administration of these analgesic regimens improved recovery as compared with that of saline-treated mice. Care should be taken when using visual assessment scores to evaluate pain in mice, given that analgesics may have side effects that inadvertently elevate the score.

  11. Seventeen Years’ Experience of Late Open Surgical Conversion after Failed Endovascular Abdominal Aortic Aneurysm Repair with 13 Variant Devices

    International Nuclear Information System (INIS)

    Wu, Ziheng; Xu, Liang; Qu, Lefeng; Raithel, Dieter

    2015-01-01

    PurposeTo investigate the causes and results of late open surgical conversion (LOSC) after failed abdominal aortic aneurysm repair (EVAR) and to summarize our 17 years’ experience with 13 various endografts.MethodsRetrospective data from August 1994 to January 2011 were analyzed at our center. The various devices’ implant time, the types of devices, the rates and causes of LOSC, and the procedures and results of LOSC were analyzed and evaluated.ResultsA total of 1729 endovascular aneurysm repairs were performed in our single center (Nuremberg South Hospital) with 13 various devices within 17 years. The median follow-up period was 51 months (range 9–119 months). Among them, 77 patients with infrarenal abdominal aortic aneurysms received LOSC. The LOSC rate was 4.5 % (77 of 1729). The LOSC rates were significantly different before and after January 2002 (p < 0.001). The reasons of LOSC were mainly large type I endoleaks (n = 51) that were hard to repair by endovascular techniques. For the LOSC procedure, 71 cases were elective and 6 were emergent. The perioperative mortality was 5.2 % (4 of 77): 1 was elective (due to septic shock) and 3 were urgent (due to hemorrhagic shock).ConclusionLarge type I endoleaks were the main reasons for LOSC. The improvement of devices and operators’ experience may decrease the LOSC rate. Urgent LOSC resulted in a high mortality rate, while selective LOSC was relatively safe with significantly lower mortality rate. Early intervention, full preparation, and timely LOSC are important for patients who require LOSC

  12. Seventeen Years’ Experience of Late Open Surgical Conversion after Failed Endovascular Abdominal Aortic Aneurysm Repair with 13 Variant Devices

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Ziheng, E-mail: wuziheng303@hotmail.com [Zhejiang University, Department of Vascular Surgery, The First Affiliated Hospital, School of Medicine (China); Xu, Liang, E-mail: maxalive@163.com [Zhejiang University, Department of Neurosurgery, The Second Affiliated Hospital, School of Medicine (China); Qu, Lefeng, E-mail: qulefeng@gmail.com [The Second Military Medical University, Department of Vascular and Endovascular Surgery, Changzheng Hospital (China); Raithel, Dieter, E-mail: dieter.raithel@rzmail.uni-erlangen.de [Nuremberg Southern Hospital, Department of Vascular and Endovascular Surgery (Germany)

    2015-02-15

    PurposeTo investigate the causes and results of late open surgical conversion (LOSC) after failed abdominal aortic aneurysm repair (EVAR) and to summarize our 17 years’ experience with 13 various endografts.MethodsRetrospective data from August 1994 to January 2011 were analyzed at our center. The various devices’ implant time, the types of devices, the rates and causes of LOSC, and the procedures and results of LOSC were analyzed and evaluated.ResultsA total of 1729 endovascular aneurysm repairs were performed in our single center (Nuremberg South Hospital) with 13 various devices within 17 years. The median follow-up period was 51 months (range 9–119 months). Among them, 77 patients with infrarenal abdominal aortic aneurysms received LOSC. The LOSC rate was 4.5 % (77 of 1729). The LOSC rates were significantly different before and after January 2002 (p < 0.001). The reasons of LOSC were mainly large type I endoleaks (n = 51) that were hard to repair by endovascular techniques. For the LOSC procedure, 71 cases were elective and 6 were emergent. The perioperative mortality was 5.2 % (4 of 77): 1 was elective (due to septic shock) and 3 were urgent (due to hemorrhagic shock).ConclusionLarge type I endoleaks were the main reasons for LOSC. The improvement of devices and operators’ experience may decrease the LOSC rate. Urgent LOSC resulted in a high mortality rate, while selective LOSC was relatively safe with significantly lower mortality rate. Early intervention, full preparation, and timely LOSC are important for patients who require LOSC.

  13. Evaluation of Sensor Configurations for Robotic Surgical Instruments.

    Science.gov (United States)

    Gómez-de-Gabriel, Jesús M; Harwin, William

    2015-10-27

    Designing surgical instruments for robotic-assisted minimally-invasive surgery (RAMIS) is challenging due to constraints on the number and type of sensors imposed by considerations such as space or the need for sterilization. A new method for evaluating the usability of virtual teleoperated surgical instruments based on virtual sensors is presented. This method uses virtual prototyping of the surgical instrument with a dual physical interaction, which allows testing of different sensor configurations in a real environment. Moreover, the proposed approach has been applied to the evaluation of prototypes of a two-finger grasper for lump detection by remote pinching. In this example, the usability of a set of five different sensor configurations, with a different number of force sensors, is evaluated in terms of quantitative and qualitative measures in clinical experiments with 23 volunteers. As a result, the smallest number of force sensors needed in the surgical instrument that ensures the usability of the device can be determined. The details of the experimental setup are also included.

  14. A software-based tool for video motion tracking in the surgical skills assessment landscape

    OpenAIRE

    Ganni, S.; Botden, Sanne M.B.I.; Chmarra, M.K.; Goossens, R.H.M.; Jakimowicz, J.J.

    2018-01-01

    Background: The use of motion tracking has been proved to provide an objective assessment in surgical skills training. Current systems, however, require the use of additional equipment or specialised laparoscopic instruments and cameras to extract the data. The aim of this study was to determine the possibility of using a software-based solution to extract the data. Methods: 6 expert and 23 novice participants performed a basic laparoscopic cholecystectomy procedure in the operating room. The...

  15. Three-dimensional aesthetic assessment of class II patients before and after orthognathic surgery and its association with quantitative surgical changes.

    Science.gov (United States)

    Storms, A S; Vansant, L; Shaheen, E; Coucke, W; de Llano-Pérula, M Cadenas; Jacobs, R; Politis, C; Willems, G

    2017-12-01

    The aim of this study was to compare evaluations of the aesthetic outcome of class II orthognathic patients, as performed by observers with varying expertise using three-dimensional (3D) facial images, and to examine the relationship of aesthetic ratings in relation to quantitative surgical changes. Pre- and postoperative 3D facial images of 20 surgically treated class II patients (13 female, 7 male) were assessed for aesthetics by orthodontists, maxillofacial surgeons, and laypeople. Attractiveness ratings for the lips, chin, and overall facial aesthetics were evaluated on a 5-point Likert scale. Correlation between the aesthetic scores was obtained and quantitative surgical changes were examined. For all groups of observers, significant improvements in attractiveness scores were found, especially for the chin assessment. Orthodontists perceived the greatest improvement and laypeople the smallest. Overall, laypeople scored higher with less variability, but with lower intra- and inter-observer agreement. No significant correlation was found between the aesthetic improvement and soft tissue surgical changes. To avoid patient dissatisfaction, it is important to bear in mind that the demands and perception of aesthetic improvement after orthognathic surgery are higher for clinicians than for the general public. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. Characterizing the Utility and Limitations of Repurposing an Open-Field Optical Imaging Device for Fluorescence-Guided Surgery in Head and Neck Cancer Patients.

    Science.gov (United States)

    Moore, Lindsay S; Rosenthal, Eben L; Chung, Thomas K; de Boer, Esther; Patel, Neel; Prince, Andrew C; Korb, Melissa L; Walsh, Erika M; Young, E Scott; Stevens, Todd M; Withrow, Kirk P; Morlandt, Anthony B; Richman, Joshua S; Carroll, William R; Zinn, Kurt R; Warram, Jason M

    2017-02-01

    The purpose of this study was to assess the potential of U.S. Food and Drug Administration-cleared devices designed for indocyanine green-based perfusion imaging to identify cancer-specific bioconjugates with overlapping excitation and emission wavelengths. Recent clinical trials have demonstrated potential for fluorescence-guided surgery, but the time and cost of the approval process may impede clinical translation. To expedite this translation, we explored the feasibility of repurposing existing optical imaging devices for fluorescence-guided surgery. Consenting patients (n = 15) scheduled for curative resection were enrolled in a clinical trial evaluating the safety and specificity of cetuximab-IRDye800 (NCT01987375). Open-field fluorescence imaging was performed preoperatively and during the surgical resection. Fluorescence intensity was quantified using integrated instrument software, and the tumor-to-background ratio characterized fluorescence contrast. In the preoperative clinic, the open-field device demonstrated potential to guide preoperative mapping of tumor borders, optimize the day of surgery, and identify occult lesions. Intraoperatively, the device demonstrated robust potential to guide surgical resections, as all peak tumor-to-background ratios were greater than 2 (range, 2.2-14.1). Postresection wound bed fluorescence was significantly less than preresection tumor fluorescence (P open-field imaging device was successfully repurposed to distinguish cancer from normal tissue in the preoperative clinic and throughout surgical resection. This study illuminated the potential for existing open-field optical imaging devices with overlapping excitation and emission spectra to be used for fluorescence-guided surgery. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  17. Assessment of bleeding during minor oral surgical procedures and extraction in patients on anticoagulant therapy

    Directory of Open Access Journals (Sweden)

    S Jimson

    2015-01-01

    Full Text Available Introduction: The risk of postoperative hemorrhage from oral surgical procedures has been a concern in the treatment of patients who are receiving long-term anticoagulation therapy. A study undertaken in our institution to address questions about the amount and severity of bleeding associated with minor outpatient oral surgery procedures by assessing bleeding in patients who did not alter their anticoagulant regimen. Subjects and Methods: Eighty-three patients receiving long-term anticoagulant therapy visited Department of Oral and Maxillofacial Surgery from May 2010 to October 2011 for extractions and minor oral surgical procedures. Each patient was required to undergo preoperative assessment of prothrombin time (PT and measurement of the international normalized ratio. Fifty-six patients with preoperative PT values within the therapeutic range 3-4 were included in the study. The patients′ age ranged between 30 and 75 years. Application of surgispon was done following the procedure. Extraction of teeth performed with minimal trauma to the surrounding tissues, the socket margins sutured, and sutures removed after 5 days. Results: There was no significant incidence of prolonged or excessive hemorrhage and wound infection and the healing process was normal.

  18. Electronic medical devices: a primer for pathologists.

    Science.gov (United States)

    Weitzman, James B

    2003-07-01

    Electronic medical devices (EMDs) with downloadable memories, such as implantable cardiac pacemakers, defibrillators, drug pumps, insulin pumps, and glucose monitors, are now an integral part of routine medical practice in the United States, and functional organ replacements, such as the artificial heart, pancreas, and retina, will most likely become commonplace in the near future. Often, EMDs end up in the hands of the pathologist as a surgical specimen or at autopsy. No established guidelines for systematic examination and reporting or comprehensive reviews of EMDs currently exist for the pathologist. To provide pathologists with a general overview of EMDs, including a brief history; epidemiology; essential technical aspects, indications, contraindications, and complications of selected devices; potential applications in pathology; relevant government regulations; and suggested examination and reporting guidelines. Articles indexed on PubMed of the National Library of Medicine, various medical and history of medicine textbooks, US Food and Drug Administration publications and product information, and specifications provided by device manufacturers. Studies were selected on the basis of relevance to the study objectives. Descriptive data were selected by the author. Suggested examination and reporting guidelines for EMDs received as surgical specimens and retrieved at autopsy. Electronic medical devices received as surgical specimens and retrieved at autopsy are increasing in number and level of sophistication. They should be systematically examined and reported, should have electronic memories downloaded when indicated, will help pathologists answer more questions with greater certainty, and should become an integral part of the formal knowledge base, research focus, training, and practice of pathology.

  19. Outpatient and Ambulatory Surgery Consumer Assessment of Healthcare Providers and Systems (OAS CAHPS) survey for ambulatory surgical centers - Facility

    Data.gov (United States)

    U.S. Department of Health & Human Services — A list of ambulatory surgical center ratings for the Outpatient and Ambulatory Surgery Consumer Assessment of Healthcare Providers and Systems (OAS CAHPS) survey....

  20. National survey of surgeons\\' attitudes to laparoscopic surgical ...

    African Journals Online (AJOL)

    Aim. Laparoscopic surgery forms an integral component of modern surgical practice. The perception exists that laparoscopic training in South Africa has been unplanned and under-resourced. This study set out to assess the opinions of surgeons and surgical trainees with regard to the various facets of laparoscopic surgical ...

  1. Assessment with Oswestry disability index in surgically treated patients with lumbar spondylolisthesis: experience in 96 patients.

    Science.gov (United States)

    Pasha, Ibrahim Farooq; Qureshi, Muhammad Asad; Farooq, Maheen; Talha, Muhammed; Ahmed, Naveed; Ismail, Junaid

    2015-11-01

    To assess the outcome of surgical treatment in spondylolisthesis of lumbosacral region using Oswestry disability Index. The quasi-experimental study was conducted at the Combined Military Hospital, Rawalpindi from 2006 to 2013 and comprised surgically treated patients with spondylolisthesis. The patients with degenerative and isthmic types with follow-up of at least two years were included. A performa was designed for each patient and records were kept in a custom-built database. Oswestry disability index was used as the assessment tool and assessment was done pre-operatively, at 1, 3 and 6 months and then at 1 year and 2 years. There were 96 patients with mean pre-op Oswestry disability index score of 81.06% (range 42.22-100, SD ±11.99). L5-S1 was affected in 44 (45.83%) patients, L4-L5 in 30 (31.25%), L4-5-S1 in 7 (7.29%) and multi or high level was found in the rest of the cases. One level was involved in 77 (80.2%), 2 in 11 (11.45%), 3 in 7 (7.29%) and 4 in 1 (1.04%). The slip grade as per Meyerding grades was 1 in 31 (32.29%), II in 39 (40.62%), III in 19 (19.79%), IV in 5 (5.2%) and 2 (2.08%) had spondyloptosis. Mean follow-up was 42 months (range 24-63). Mean Oswestry disability score at 1 month was 38.51% (range 11- 62.22%, SD ±11.75); at 6 months 10.02% (range 0-40%, SD ±6.99); at 1 year 4.62% (range 0-24%, SD ±5.36) and at 2 years 4.21% (range 0-15%, SD ±4.2). Surgical treatment of spondylolisthesis gives excellent long-term result in most patients.

  2. Development and participant assessment of a practical quality improvement educational initiative for surgical residents.

    Science.gov (United States)

    Sellers, Morgan M; Hanson, Kristi; Schuller, Mary; Sherman, Karen; Kelz, Rachel R; Fryer, Jonathan; DaRosa, Debra; Bilimoria, Karl Y

    2013-06-01

    As patient-safety and quality efforts spread throughout health care, the need for physician involvement is critical, yet structured training programs during surgical residency are still uncommon. Our objective was to develop an extended quality-improvement curriculum for surgical residents that included formal didactics and structured practical experience. Surgical trainees completed an 8-hour didactic program in quality-improvement methodology at the start of PGY3. Small teams developed practical quality-improvement projects based on needs identified during clinical experience. With the assistance of the hospital's process-improvement team and surgical faculty, residents worked through their selected projects during the following year. Residents were anonymously surveyed after their participation to assess the experience. During the first 3 years of the program, 17 residents participated, with 100% survey completion. Seven quality-improvement projects were developed, with 57% completing all DMAIC (Define, Measure, Analyze, Improve, Control) phases. Initial projects involved issues of clinical efficiency and later projects increasingly focused on clinical care questions. Residents found the experience educationally important (65%) and believed they were well equipped to lead similar initiatives in the future (70%). Based on feedback, the timeline was expanded from 12 to 24 months and changed to start in PGY2. Developing an extended curriculum using both didactic sessions and applied projects to teach residents the theory and implementation of quality improvement is possible and effective. It addresses the ACGME competencies of practice-based improvement and learning and systems-based practice. Our iterative experience during the past 3 years can serve as a guide for other programs. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  3. SAGES TAVAC safety and effectiveness analysis: da Vinci ® Surgical System (Intuitive Surgical, Sunnyvale, CA).

    Science.gov (United States)

    Tsuda, Shawn; Oleynikov, Dmitry; Gould, Jon; Azagury, Dan; Sandler, Bryan; Hutter, Matthew; Ross, Sharona; Haas, Eric; Brody, Fred; Satava, Richard

    2015-10-01

    The da Vinci(®) Surgical System (Intuitive Surgical, Sunnyvale, CA, USA) is a computer-assisted (robotic) surgical system designed to enable and enhance minimally invasive surgery. The Food and Drug Administration (FDA) has cleared computer-assisted surgical systems for use by trained physicians in an operating room environment for laparoscopic surgical procedures in general, cardiac, colorectal, gynecologic, head and neck, thoracic and urologic surgical procedures. There are substantial numbers of peer-reviewed papers regarding the da Vinci(®) Surgical System, and a thoughtful assessment of evidence framed by clinical opinion is warranted. The SAGES da Vinci(®) TAVAC sub-committee performed a literature review of the da Vinci(®) Surgical System regarding gastrointestinal surgery. Conclusions by the sub-committee were vetted by the SAGES TAVAC Committee and SAGES Executive Board. Following revisions, the document was evaluated by the TAVAC Committee and Executive Board again for final approval. Several conclusions were drawn based on expert opinion organized by safety, efficacy, and cost for robotic foregut, bariatric, hepatobiliary/pancreatic, colorectal surgery, and single-incision cholecystectomy. Gastrointestinal surgery with the da Vinci(®) Surgical System is safe and comparable, but not superior to standard laparoscopic approaches. Although clinically acceptable, its use may be costly for select gastrointestinal procedures. Current data are limited to the da Vinci(®) Surgical System; further analyses are needed.

  4. Deep Neuromuscular Blockade Improves Laparoscopic Surgical Conditions

    DEFF Research Database (Denmark)

    Rosenberg, Jacob; Herring, W Joseph; Blobner, Manfred

    2017-01-01

    INTRODUCTION: Sustained deep neuromuscular blockade (NMB) during laparoscopic surgery may facilitate optimal surgical conditions. This exploratory study assessed whether deep NMB improves surgical conditions and, in doing so, allows use of lower insufflation pressures during laparoscopic cholecys...

  5. Determining the need for team-based training in delirium management: A needs assessment of surgical healthcare professionals.

    Science.gov (United States)

    Sockalingam, Sanjeev; Tehrani, Hedieh; Kacikanis, Anna; Tan, Adrienne; Hawa, Raed; Anderson, Ruthie; Okrainec, Allan; Abbey, Susan

    2015-01-01

    The high incidence of delirium in surgical units is a serious quality concern, given its impact on morbidity and mortality. While successful delirium management depends upon interdisciplinary care, training needs for surgical teams have not been studied. A needs assessment of surgical units was conducted to determine perceived comfort in managing delirium, and interprofessional training needs for team-based care. We administered a survey to 106 General Surgery healthcare professionals (69% response rate) with a focus on attitudes towards delirium and team management. Although most respondents identified delirium as important to patient outcomes, only 61% of healthcare professionals indicated that a team-based approach was always observed in practice. Less than half had a clear understanding of their role in delirium care, while just over half observed team communication of delirium care plans during handover. This is the first observation of clear gaps in perceived team performance in a General Surgery setting.

  6. Cognitive learning and its future in urology: surgical skills teaching and assessment.

    Science.gov (United States)

    Shafiei, Somayeh B; Hussein, Ahmed A; Guru, Khurshid A

    2017-07-01

    The aim of this study is to provide an overview of the current status of novel cognitive training approaches in surgery and to investigate the potential role of cognitive training in surgical education. Kinematics of end-effector trajectories, as well as cognitive state features of surgeon trainees and mentors have recently been studied as modalities to objectively evaluate the expertise level of trainees and to shorten the learning process. Virtual reality and haptics also have shown promising in research results in improving the surgical learning process by providing feedback to the trainee. 'Cognitive training' is a novel approach to enhance training and surgical performance. The utility of cognitive training in improving motor skills in other fields, including sports and rehabilitation, is promising enough to justify its utilization to improve surgical performance. However, some surgical procedures, especially ones performed during human-robot interaction in robot-assisted surgery, are much more complicated than sport and rehabilitation. Cognitive training has shown promising results in surgical skills-acquisition in complicated environments such as surgery. However, these methods are mostly developed in research groups using limited individuals. Transferring this research into the clinical applications is a demanding challenge. The aim of this review is to provide an overview of the current status of these novel cognitive training approaches in surgery and to investigate the potential role of cognitive training in surgical education.

  7. Accomplishments and challenges of surgical simulation.

    Science.gov (United States)

    Satava, R M

    2001-03-01

    For nearly a decade, advanced computer technologies have created extraordinary educational tools using three-dimensional (3D) visualization and virtual reality. Pioneering efforts in surgical simulation with these tools have resulted in a first generation of simulators for surgical technical skills. Accomplishments include simulations with 3D models of anatomy for practice of surgical tasks, initial assessment of student performance in technical skills, and awareness by professional societies of potential in surgical education and certification. However, enormous challenges remain, which include improvement of technical fidelity, standardization of accurate metrics for performance evaluation, integration of simulators into a robust educational curriculum, stringent evaluation of simulators for effectiveness and value added to surgical training, determination of simulation application to certification of surgical technical skills, and a business model to implement and disseminate simulation successfully throughout the medical education community. This review looks at the historical progress of surgical simulators, their accomplishments, and the challenges that remain.

  8. Risk assessment of medical devices: evaluation of microbiological and toxicological safety

    International Nuclear Information System (INIS)

    Dorpema, J.W.

    1995-01-01

    Safety assessment of medical devices includes sterilization and biological evaluation or biocompatability testing. Sterilization by ETO gas is criticised for their carcinogenic potency or even banned. Mutual acceptance of biological evaluation test results is promoted by a laboratory accreditation and qualification program. (Author)

  9. [Clinical Experience of Beating Heart Atrial Septostomy Using a Device for Coronary Artery Anastomosis Site Creator].

    Science.gov (United States)

    Takahashi, Goro; Sai, Sadahiro; Konishi, Akinobu

    2015-09-01

    Intra-atrial communication was mandatory for several congenital cardiac diseases, such as pulmonary atresia with intact ventricular septum (PA/IVS), and either sided aortoventricular valve atresia. We assessed whether the new methods of atrial septal defect(ASD)creation was effective. We experienced 4 cases of the surgical atrial septostomy performed under on-pump beating. We used a new device, a circular punch out defect creator. All cases were alive. The mean ASD diameter was enlarged from 4.37 mm to 5.55 mm and the mean ASD shunt flow was significantly decreased from 1.47 m/s to 1.11 m/s. We performed the surgical atrial septostomy using an aortic puncher under beating heart effectively and safely.

  10. Practice of Regulatory Science (Development of Medical Devices).

    Science.gov (United States)

    Niimi, Shingo

    2017-01-01

    Prototypes of medical devices are made in accordance with the needs of clinical practice, and for systems required during the initial process of medical device development for new surgical practices. Verification of whether these prototypes produce the intended performance specifications is conducted using basic tests such as mechanical and animal tests. The prototypes are then improved and modified until satisfactory results are obtained. After a prototype passes through a clinical trial process similar to that for new drugs, application for approval is made. In the approval application process, medical devices are divided into new, improved, and generic types. Reviewers judge the validity of intended use, indications, operation procedures, and precautions, and in addition evaluate the balance between risk and benefit in terms of efficacy and safety. Other characteristics of medical devices are the need for the user to attain proficiency in usage techniques to ensure efficacy and safety, and the existence of a variety of medical devices for which assessment strategies differ, including differences in impact on the body in cases in which a physical burden to the body or failure of a medical device develops. Regulatory science of medical devices involves prediction, judgment, and evaluation of efficacy, safety, and quality, from which data result which can become indices in the development stages from design to application for approval. A reduction in the number of animals used for testing, improvement in efficiency, reduction of the necessity for clinical trials, etc. are expected through rational setting of evaluation items.

  11. New technologies and surgical innovation: five years of a local health technology assessment program in a surgical department.

    Science.gov (United States)

    Poulin, Paule; Austen, Lea; Kortbeek, John B; Lafrenière, René

    2012-06-01

    There is pressure for surgical departments to introduce new and innovative health technologies in an evidence-based manner while ensuring that they are safe and effective and can be managed with available resources. A local health technology assessment (HTA) program was developed to systematically integrate research evidence with local operational management information and to make recommendations for subsequent decision by the departmental executive committee about whether and under what conditions the technology will be used. The authors present a retrospective analysis of the outcomes of this program as used by the Department of Surgery & Surgical Services in the Calgary Health Region over a 5-year period from December 2005 to December 2010. Of the 68 technologies requested, 15 applications were incomplete and dropped, 12 were approved, 3 were approved for a single case on an urgent/emergent basis, 21 were approved for "clinical audit" for a restricted number of cases with outcomes review, 14 were approved for research use only, and 3 were referred to additional review bodies. Subsequent outcome reports resulted in at least 5 technologies being dropped for failure to perform. Decisions based on local HTA program recommendations were rarely "yes" or "no." Rather, many technologies were given restricted approval with full approval contingent on satisfying certain conditions such as clinical outcomes review, training protocol development, or funding. Thus, innovation could be supported while ensuring safety and effectiveness. This local HTA program can be adapted to a variety of settings and can help bridge the gap between evidence and practice.

  12. Nerve Surgeons' Assessment of the Role of Eduard Pernkopf's Atlas of Topographic and Applied Human Anatomy in Surgical Practice.

    Science.gov (United States)

    Yee, Andrew; Coombs, Demetrius M; Hildebrandt, Sabine; Seidelman, William E; Coert, J Henk; Mackinnon, Susan E

    2018-05-08

    Pernkopf's atlas of Anatomy contains anatomical plates with detailed images of the peripheral nerves. Its use is controversial due to the author's association with the "Third Reich" and the potential depiction of victims of the Holocaust. The ethical implications of using this atlas for informing surgical planning have not been assessed. To (1) assess the role of Pernkopf's atlas in nerve surgeons' current practice and (2) determine whether a proposal for its ethical handling may provide possible guidance for use in surgery and surgical education. Members of American Society for Peripheral Nerve and PASSIO Education (video-based learning platform) were surveyed and 182 responses collected. The survey introduced the historical origin of Pernkopf's atlas, and respondents were asked whether they would use the atlas under specific conditions to serve as a recommendation for its ethical handling. An anatomical plate comparison between Netter's and Pernkopf's atlases was performed to compare anatomical accuracy and surgical utility. Fifty-nine percent of respondents were aware of Pernkopf's atlas, with 13% currently using it. Aware of the historical facts, 69% were comfortable using the atlas, 15% uncomfortable, and 17% undecided. Additional information on conditions for an ethical approach to the use of the atlas led 76% of those "uncomfortable" and "undecided" to becoming "comfortable" with use. While the use of Pernkopf's atlas remains controversial, a proposal detailing conditions for an ethical approach in its use provides new guidance in surgical planning and education.

  13. Assessment of radiographic factors affecting surgical exposure and orthodontic alignment of impacted canines of the palate: a 15-year retrospective study.

    Science.gov (United States)

    Motamedi, Mohammad Hosein Kalantar; Tabatabaie, Fataneh Alavi; Navi, Fina; Shafeie, Hasan Ali; Fard, Behnam Khosravani; Hayati, Zahra

    2009-06-01

    Impacted canines require a combination of both surgical and orthodontic management. In this study, patients treated for bone-impacted canines of the hard palatal were evaluated to assess which radiographic factors influenced the feasibility to move impacted maxillary permanent canines from the hard palate into the alveolar arch. Eighty patients aged 12 to 24 (average 16 years) were treated surgically and orthodontically to align 146 bone-impacted canines of the hard palate (from 1994 to 2008). Factors such as age, sex, angulation of the canine to the midline (CAM), anomaly of the canine root (RA), overlap of the adjacent lateral incisor root (OALIR), and ratio of root formation (RRF) upon treatment were documented. Radiographic records and demographic data were assessed. The following radiographic measurements of canine position were made from the orthopantomogram (OPG): (1) angulation to the midline, (2) anteroposterior position of the root, (3) overlap of the adjacent incisor. RA or dilaceration was assessed from the OPG, maxillary occlusal (MO), and periapical (PA) radiographs. Whether the impacted canine had responded to surgical exposure and was orthodontically aligned, or surgically removed and discarded was also recorded. The data were analyzed to assess and correlate significance. Eighty patients aged 12 to 24 (19 males and 61 females) with 146 bone-impacted permanent canines of the hard palatal were treated. One hundred and three teeth (70.54%) had responded to surgical exposure and orthodontic alignment within 9 to 12 months. Forty-three impacted canine teeth (29.46%) had to be surgically removed because of ankylosis and no movement after 8 to 9 months using 50 to 60 g of traction force via elastic chains. Data analysis via chi-square and Pearson correlation tests showed that as the CAM increased (> 45 degrees), the canine was more likely to be unresponsive to treatment (P half the root) of the adjacent lateral incisor root (OALIR) via the canine crown

  14. Incorporating simulation into gynecologic surgical training.

    Science.gov (United States)

    Wohlrab, Kyle; Jelovsek, J Eric; Myers, Deborah

    2017-11-01

    Today's educational environment has made it more difficult to rely on the Halstedian model of "see one, do one, teach one" in gynecologic surgical training. There is decreased surgical volume, but an increased number of surgical modalities. Fortunately, surgical simulation has evolved to fill the educational void. Whether it is through skill generalization or skill transfer, surgical simulation has shifted learning from the operating room back to the classroom. This article explores the principles of surgical education and ways to introduce simulation as an adjunct to residency training. We review high- and low-fidelity surgical simulators, discuss the progression of surgical skills, and provide options for skills competency assessment. Time and money are major hurdles when designing a simulation curriculum, but low-fidelity models, intradepartmental cost sharing, and utilizing local experts for simulation proctoring can aid in developing a simulation program. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. A Systematic Review on Existing Measures for the Subjective Assessment of Rehabilitation and Assistive Robot Devices

    Directory of Open Access Journals (Sweden)

    Yiannis Koumpouros

    2016-01-01

    Full Text Available The objective of the current study is to identify and classify outcome measures currently used for the assessment of rehabilitation or assistive robot devices. We conducted a systematic review of the literature using PubMed, MEDLINE, CIRRIE, and Scopus databases for studies that assessed rehabilitation or assistive robot devices from 1980 through January 2016. In all, 31 articles met all inclusion criteria. Tailor-made questionnaires were the most commonly used tool at 66.7%, while the great majority (93.9% of the studies used nonvalidated instruments. The study reveals the absence of a standard scale which makes it difficult to compare the results from different researchers. There is a great need, therefore, for a valid and reliable instrument to be available for use by the intended end users for the subjective assessment of robot devices. The study concludes by identifying two scales that have been validated in general assistive technology devices and could support the scope of subjective assessment in rehabilitation or assistive robots (however, with limited coverage and a new one called PYTHEIA, recently published. The latter intends to close the gap and help researchers and developers to evaluate, assess, and produce products that satisfy the real needs of the end users.

  16. An Assessment of Clinical Interchangeability of TEG (R) and RoTEM (R) Thromboelastographic Variables in Cardiac Surgical Patients

    NARCIS (Netherlands)

    Venema, L.F.; Post, W.J.; Hendriks, H.G.D.; Huet, R.C.G.; de Wolf, J.T.W.; de Vries, A.J.

    BACKGROUND: Bedside thromboelastography is increasingly used, but an assessment of the clinical interchangeability of the 2 major systems, TEG (R) (Hemoscope) and RoTEM (R) (Pentapharm), has not been performed. METHODS: We measured blood samples from 46 cardiac surgical patients after induction of

  17. Accuracy Assessment of Immediate and Delayed Implant Placements Using CAD/CAM Surgical Guides.

    Science.gov (United States)

    Alzoubi, Fawaz; Massoomi, Nima; Nattestad, Anders

    2016-10-01

    The aim of this study is to assess the accuracy of immediately placed implants using Anatomage Invivo5 computer-assisted design/computer-assisted manufacturing (CAD/CAM) surgical guides and compare the accuracy to delayed implant placement protocol. Patients who had implants placed using Anatomage Invivo5 CAD/CAM surgical guides during the period of 2012-2015 were evaluated retrospectively. Patients who received immediate implant placements and/or delayed implant placements replacing 1-2 teeth were included in this study. Pre- and postsurgical images were superimposed to evaluate deviations at the crest, apex, and angle. A total of 40 implants placed in 29 patients were included in this study. The overall mean deviations measured at the crest, apex, and angle were 0.86 mm, 1.25 mm, and 3.79°, respectively. The means for the immediate group deviations were: crest = 0.85 mm, apex = 1.10, and angle = 3.49°. The means for the delayed group deviations were: crest = 0.88 mm, apex = 1.59, and angle = 4.29°. No statistically significant difference was found at the crest and angle; however, there was a statistically significant difference between the immediate and delayed group at the apex, with the immediate group presenting more accurate placements at the apical point than the delayed group. CAD/CAM surgical guides can be reliable tools to accurately place implants immediately and/or in a delayed fashion. No statistically significant differences were found between the delayed and the immediate group at the crest and angle, however apical position was more accurate in the immediate group.

  18. Wound edge protectors in open abdominal surgery to reduce surgical site infections: a systematic review and meta-analysis.

    Directory of Open Access Journals (Sweden)

    André L Mihaljevic

    Full Text Available Surgical site infections remain one of the most frequent complications following abdominal surgery and cause substantial costs, morbidity and mortality.To assess the effectiveness of wound edge protectors in open abdominal surgery in reducing surgical site infections.A systematic literature search was conducted according to a prespecified review protocol in a variety of data-bases combined with hand-searches for randomized controlled trials on wound edge protectors in patients undergoing laparotomy. A qualitative and quantitative analysis of included trials was conducted.We identified 16 randomized controlled trials including 3695 patients investigating wound edge protectors published between 1972 and 2014. Critical appraisal uncovered a number of methodological flaws, predominantly in the older trials. Wound edge protectors significantly reduced the rate of surgical site infections (risk ratio 0.65; 95%CI, 0.51-0.83; p = 0.0007; I2 = 52%. The results were robust in a number of sensitivity analyses. A similar effect size was found in the subgroup of patients undergoing colorectal surgery (risk ratio 0.65; 95%CI, 0.44-0.97; p = 0.04; I2 = 56%. Of the two common types of wound protectors double ring devices were found to exhibit a greater protective effect (risk ratio 0.29; 95%CI, 0.15-0.55 than single-ring devices (risk ratio 0.71; 95%CI, 0.54-0.92, but this might largely be due to the lower quality of available data for double-ring devices. Exploratory subgroup analyses for the degree of contamination showed a larger protective effect in contaminated cases (0.44; 95%CI, 0.28-0.67; p = 0.0002, I2 = 23% than in clean-contaminated surgeries (0.72, 95%CI, 0.57-0.91; p = 0.005; I2 = 46% and a strong effect on the reduction of superficial surgical site infections (risk ratio 0.45; 95%CI, 0.24-0.82; p = 0.001; I2 = 72%.Wound edge protectors significantly reduce the rate of surgical site infections in open abdominal surgery. Further trials are needed to

  19. Automated processing of endoscopic surgical instruments.

    Science.gov (United States)

    Roth, K; Sieber, J P; Schrimm, H; Heeg, P; Buess, G

    1994-10-01

    This paper deals with the requirements for automated processing of endoscopic surgical instruments. After a brief analysis of the current problems, solutions are discussed. Test-procedures have been developed to validate the automated processing, so that the cleaning results are guaranteed and reproducable. Also a device for testing and cleaning was designed together with Netzsch Newamatic and PCI, called TC-MIC, to automate processing and reduce manual work.

  20. 78 FR 4094 - Effective Date of Requirement for Premarket Approval for Two Class III Preamendments Devices

    Science.gov (United States)

    2013-01-18

    ... devices. On August 8, 2001, the Orthopaedic and Rehabilitation Devices Panel (the Panel) recommended five... function due to excessive wear, fracture, deformation of the device components, or loosening of the device... excessive wear, fracture, deformation of the device components, or loosening of the device in the surgical...

  1. Surgical therapy in chronic pancreatitis.

    Science.gov (United States)

    Neal, C P; Dennison, A R; Garcea, G

    2012-12-01

    Chronic pancreatitis (CP) is an inflammatory disease of the pancreas which causes chronic pain, as well as exocrine and endocrine failure in the majority of patients, together producing social and domestic upheaval and a very poor quality of life. At least half of patients will require surgical intervention at some stage in their disease, primarily for the treatment of persistent pain. Available data have now confirmed that surgical intervention may produce superior results to conservative and endoscopic treatment. Comprehensive individual patient assessment is crucial to optimal surgical management, however, in order to determine which morphological disease variant (large duct disease, distal stricture with focal disease, expanded head or small duct/minimal change disease) is present in the individual patient, as a wide and differing range of surgical approaches are possible depending upon the specific abnormality within the gland. This review comprehensively assesses the evidence for these differing approaches to surgical intervention in chronic pancreatitis. Surgical drainage procedures should be limited to a small number of patients with a dilated duct and no pancreatic head mass. Similarly, a small population presenting with a focal stricture and tail only disease may be successfully treated by distal pancreatectomy. Long-term results of both of these procedure types are poor, however. More impressive results have been yielded for the surgical treatment of the expanded head, for which a range of surgical options now exist. Evidence from level I studies and a recent meta-analysis suggests that duodenum-preserving resections offer benefits compared to pancreaticoduodenectomy, though the results of the ongoing, multicentre ChroPac trial are awaited to confirm this. Further data are also needed to determine which of the duodenum-preserving procedures provides optimal results. In relation to small duct/minimal change disease total pancreatectomy represents the only

  2. Image-guided neurosurgery. Global concept of a surgical tele-assistance using obstacle detection robotics

    International Nuclear Information System (INIS)

    Desgeorges, M.; Bellegou, N.; Faillot, Th.; Cordoliani, Y.S.; Dutertre, G.; Blondet, E.; Soultrait, F. de; Boissy, J.M.

    2000-01-01

    Surgical tele-assistance significantly increases accuracy of surgical gestures, especially in the case of brain tumor neurosurgery. The robotic device is tele-operated through a microscope and the surgeon's gestures are guided by real-time overlaying of the X-ray imagery in the microscope. During the device's progression inside the brain, the focus is ensured by the microscope auto-focus feature. The surgeon can thus constantly check his position on the field workstation. Obstacles to avoid or dangerous areas can be previewed in the operation field. This system is routinely used for 5 years in the neurosurgery division of the Val de Grace hospital. More than 400 brain surgery operations have been done using it. An adaptation is used for rachis surgery. Other military hospitals begin to be equipped with similar systems. It will be possible to link them for data transfer. When it will be operational, such a network it will show what could be, in the future, a medical/surgical remote-assistance system designed to take care of wounded/critical conditions people, including assistance to surgical gestures. (authors)

  3. Fontan Surgical Planning: Previous Accomplishments, Current Challenges, and Future Directions.

    Science.gov (United States)

    Trusty, Phillip M; Slesnick, Timothy C; Wei, Zhenglun Alan; Rossignac, Jarek; Kanter, Kirk R; Fogel, Mark A; Yoganathan, Ajit P

    2018-04-01

    The ultimate goal of Fontan surgical planning is to provide additional insights into the clinical decision-making process. In its current state, surgical planning offers an accurate hemodynamic assessment of the pre-operative condition, provides anatomical constraints for potential surgical options, and produces decent post-operative predictions if boundary conditions are similar enough between the pre-operative and post-operative states. Moving forward, validation with post-operative data is a necessary step in order to assess the accuracy of surgical planning and determine which methodological improvements are needed. Future efforts to automate the surgical planning process will reduce the individual expertise needed and encourage use in the clinic by clinicians. As post-operative physiologic predictions improve, Fontan surgical planning will become an more effective tool to accurately model patient-specific hemodynamics.

  4. Standardised metrics for global surgical surveillance.

    Science.gov (United States)

    Weiser, Thomas G; Makary, Martin A; Haynes, Alex B; Dziekan, Gerald; Berry, William R; Gawande, Atul A

    2009-09-26

    Public health surveillance relies on standardised metrics to evaluate disease burden and health system performance. Such metrics have not been developed for surgical services despite increasing volume, substantial cost, and high rates of death and disability associated with surgery. The Safe Surgery Saves Lives initiative of WHO's Patient Safety Programme has developed standardised public health metrics for surgical care that are applicable worldwide. We assembled an international panel of experts to develop and define metrics for measuring the magnitude and effect of surgical care in a population, while taking into account economic feasibility and practicability. This panel recommended six measures for assessing surgical services at a national level: number of operating rooms, number of operations, number of accredited surgeons, number of accredited anaesthesia professionals, day-of-surgery death ratio, and postoperative in-hospital death ratio. We assessed the feasibility of gathering such statistics at eight diverse hospitals in eight countries and incorporated them into the WHO Guidelines for Safe Surgery, in which methods for data collection, analysis, and reporting are outlined.

  5. Povidone-iodine induced post-surgical irritant contact dermatitis localized outside of the surgical incision area. Report of 27 cases and a literature review.

    Science.gov (United States)

    Borrego, Leopoldo; Hernández, Noelia; Hernández, Zaida; Peñate, Yeray

    2016-05-01

    Povidone-iodine solution is an antiseptic that is used worldwide as surgical paint and is considered to have a low irritant potential. Post-surgical severe irritant dermatitis has been described after the misuse of this antiseptic in the surgical setting. Between January 2011 and June 2013, 27 consecutive patients with post-surgical contact dermatitis localized outside of the surgical incision area were evaluated. Thirteen patients were also available for patch testing. All patients developed dermatitis the day after the surgical procedure. Povidone-iodine solution was the only liquid in contact with the skin of our patients. Most typical lesions were distributed in a double lumbar parallel pattern, but they were also found in a random pattern or in areas where a protective pad or an occlusive medical device was glued to the skin. The patch test results with povidone-iodine were negative. Povidone-iodine-induced post-surgical dermatitis may be a severe complication after prolonged surgical procedures. As stated in the literature and based on the observation that povidone-iodine-induced contact irritant dermatitis occurred in areas of pooling or occlusion, we speculate that povidone-iodine together with occlusion were the causes of the dermatitis epidemic that occurred in our surgical setting. Povidone-iodine dermatitis is a problem that is easily preventable through the implementation of minimal routine changes to adequately dry the solution in contact with the skin. © 2015 The International Society of Dermatology.

  6. Provision of general paediatric surgical services in a regional hospital.

    LENUS (Irish Health Repository)

    Zgraj, O

    2012-01-31

    BACKGROUND: In Ireland, specialist paediatric surgery is carried out in paediatric hospitals in Dublin. General surgeons\\/consultants in other surgical specialities provide paediatric surgical care in regional centres. There has been a failure to train general surgeons with paediatric skills to replace these surgeons upon retirement. AIM: To assess paediatric surgical workload in one regional centre to focus the debate regarding the future provision of general paediatric surgery in Ireland. METHODS: Hospital in-patient enquiry (HIPE) system was used to identify total number of paediatric surgical admissions and procedures. Cases assessed requiring hospital transfer. RESULTS: Of 17,478 surgical patients treated, 2,584 (14.8%) were under 14 years. A total of 2,154 procedures were performed. CONCLUSION: Regional centres without dedicated paediatric surgeons deliver care to large numbers of paediatric patients. The demand for care highlights the need for formal paediatric services\\/appropriate surgical training for general surgical trainees.

  7. Video-Based Surgical Learning: Improving Trainee Education and Preparation for Surgery.

    Science.gov (United States)

    Mota, Paulo; Carvalho, Nuno; Carvalho-Dias, Emanuel; João Costa, Manuel; Correia-Pinto, Jorge; Lima, Estevão

    2017-10-11

    Since the end of the XIX century, teaching of surgery has remained practically unaltered until now. With the dawn of video-assisted laparoscopy, surgery has faced new technical and learning challenges. Due to technological advances, from Internet access to portable electronic devices, the use of online resources is part of the educational armamentarium. In this respect, videos have already proven to be effective and useful, however the best way to benefit from these tools is still not clearly defined. To assess the importance of video-based learning, using an electronic questionnaire applied to residents and specialists of different surgical fields. Importance of video-based learning was assessed in a sample of 141 subjects, using a questionnaire distributed by a GoogleDoc online form. We found that 98.6% of the respondents have already used videos to prepare for surgery. When comparing video sources by formation status, residents were found to use Youtube significantly more often than specialists (p learning is currently a hallmark of surgical preparation among residents and specialists working in Portugal. Based on these findings we believe that the creation of quality and scientifically accurate videos, and subsequent compilation in available video-libraries appears to be the future landscape for video-based learning. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  8. Improving core surgical training in a major trauma centre.

    Science.gov (United States)

    Morris, Daniel L J; Bryson, David J; Ollivere, Ben J; Forward, Daren P

    2016-06-01

    English Major Trauma Centres (MTCs) were established in April 2012. Increased case volume and complexity has influenced trauma and orthopaedic (T&O) core surgical training in these centres. To determine if T&O core surgical training in MTCs meets Joint Committee on Surgical Training (JCST) quality indicators including performance of T&O operative procedures and consultant supervised session attendance. An audit cycle assessing the impact of a weekly departmental core surgical trainee rota. The rota included allocated timetabled sessions that optimised clinical and surgical learning opportunities. Intercollegiate Surgical Curriculum Programme (ISCP) records for T&O core surgical trainees at a single MTC were analysed for 8 months pre and post rota introduction. Outcome measures were electronic surgical logbook evidence of leading T&O operative procedures and consultant validated work-based assessments (WBAs). Nine core surgical trainees completed a 4 month MTC placement pre and post introduction of the core surgical trainee rota. Introduction of core surgical trainee rota significantly increased the mean number of T&O operative procedures led by a core surgical trainee during a 4 month MTC placement from 20.2 to 34.0 (pcore surgical trainee during a 4 month MTC placement was significantly increased (0.3 vs 2.4 [p=0.04]). Those of dynamic hip screw fixation (2.3 vs 3.6) and ankle fracture fixation (0.7 vs 1.6) were not. Introduction of a core surgical trainee rota significantly increased the mean number of consultant validated WBAs completed by a core surgical trainee during a 4 month MTC placement from 1.7 to 6.6 (pcore surgical trainee rota utilising a 'problem-based' model can significantly improve T&O core surgical training in MTCs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Evaluation of Sensor Configurations for Robotic Surgical Instruments

    Directory of Open Access Journals (Sweden)

    Jesús M. Gómez-de-Gabriel

    2015-10-01

    Full Text Available Designing surgical instruments for robotic-assisted minimally-invasive surgery (RAMIS is challenging due to constraints on the number and type of sensors imposed by considerations such as space or the need for sterilization. A new method for evaluating the usability of virtual teleoperated surgical instruments based on virtual sensors is presented. This method uses virtual prototyping of the surgical instrument with a dual physical interaction, which allows testing of different sensor configurations in a real environment. Moreover, the proposed approach has been applied to the evaluation of prototypes of a two-finger grasper for lump detection by remote pinching. In this example, the usability of a set of five different sensor configurations, with a different number of force sensors, is evaluated in terms of quantitative and qualitative measures in clinical experiments with 23 volunteers. As a result, the smallest number of force sensors needed in the surgical instrument that ensures the usability of the device can be determined. The details of the experimental setup are also included.

  10. Evaluation of Sensor Configurations for Robotic Surgical Instruments

    Science.gov (United States)

    Gómez-de-Gabriel, Jesús M.; Harwin, William

    2015-01-01

    Designing surgical instruments for robotic-assisted minimally-invasive surgery (RAMIS) is challenging due to constraints on the number and type of sensors imposed by considerations such as space or the need for sterilization. A new method for evaluating the usability of virtual teleoperated surgical instruments based on virtual sensors is presented. This method uses virtual prototyping of the surgical instrument with a dual physical interaction, which allows testing of different sensor configurations in a real environment. Moreover, the proposed approach has been applied to the evaluation of prototypes of a two-finger grasper for lump detection by remote pinching. In this example, the usability of a set of five different sensor configurations, with a different number of force sensors, is evaluated in terms of quantitative and qualitative measures in clinical experiments with 23 volunteers. As a result, the smallest number of force sensors needed in the surgical instrument that ensures the usability of the device can be determined. The details of the experimental setup are also included. PMID:26516863

  11. HEALTH TECHNOLOGY ASSESSMENT OF MEDICAL DEVICES IN EUROPE: PROCESSES, PRACTICES, AND METHODS.

    Science.gov (United States)

    Fuchs, Sabine; Olberg, Britta; Panteli, Dimitra; Busse, Reinhard

    2016-01-01

    To review and compare current Health Technology Assessment (HTA) activities for medical devices (MDs) across European HTA institutions. A comprehensive approach was adopted to identify institutions involved in HTA in European countries. We systematically searched institutional Web sites and other online sources by using a structured tool to extract information on the role and link to decision making, structure, scope, process, methodological approach, and available HTA reports for each included institution. Information was obtained from eighty-four institutions, forty-seven of which were analyzed. Fifty-four methodological documents from twenty-three agencies in eighteen countries were identified. Only five agencies had separate documents for the assessment of MDs. A few agencies made separate provisions for the assessment of MDs in their general methods. The amount of publicly available HTA reports on MDs varied by device category and agency remit. Despite growing consensus on their importance and international initiatives, such as the EUnetHTA Core Model®, specific tools for the assessment of MDs are rarely developed and implemented at the national level. Separate additional signposts incorporated in existing general methods guides may be sufficient for the evaluation of MDs.

  12. Simulation for ward processes of surgical care.

    Science.gov (United States)

    Pucher, Philip H; Darzi, Ara; Aggarwal, Rajesh

    2013-07-01

    The role of simulation in surgical education, initially confined to technical skills and procedural tasks, increasingly includes training nontechnical skills including communication, crisis management, and teamwork. Research suggests that many preventable adverse events can be attributed to nontechnical error occurring within a ward context. Ward rounds represent the primary point of interaction between patient and physician but take place without formalized training or assessment. The simulated ward should provide an environment in which processes of perioperative care can be performed safely and realistically, allowing multidisciplinary assessment and training of full ward rounds. We review existing literature and describe our experience in setting up our ward simulator. We examine the facilities, equipment, cost, and personnel required for establishing a surgical ward simulator and consider the scenario development, assessment, and feedback tools necessary to integrate it into a surgical curriculum. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Systematic Review of the Use of 3-Dimensional Printing in Surgical Teaching and Assessment.

    Science.gov (United States)

    Langridge, Benjamin; Momin, Sheikh; Coumbe, Ben; Woin, Evelina; Griffin, Michelle; Butler, Peter

    The use of 3-dimensional (3D) printing in medicine has rapidly expanded in recent years as the technology has developed. The potential uses of 3D printing are manifold. This article provides a systematic review of the uses of 3D printing within surgical training and assessment. A structured literature search of the major literature databases was performed in adherence to PRISMA guidelines. Articles that met predefined inclusion and exclusion criteria were appraised with respect to the key objectives of the review and sources of bias were analysed. Overall, 49 studies were identified for inclusion in the qualitative analysis. Heterogeneity in study design and outcome measures used prohibited meaningful meta-analysis. 3D printing has been used in surgical training across a broad range of specialities but most commonly in neurosurgery and otorhinolaryngology. Both objective and subjective outcome measures have been studied, demonstrating the usage of 3D printed models in training and education. 3D printing has also been used in anatomical education and preoperative planning, demonstrating improved outcomes when compared to traditional educational methods and improved patient outcomes, respectively. 3D printing technology has a broad range of potential applications within surgical education and training. Although the field is still in its relative infancy, several studies have already demonstrated its usage both instead of and in addition to traditional educational methods. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  14. Dietary assessment and self-monitoring with nutrition applications for mobile devices.

    Science.gov (United States)

    Lieffers, Jessica R L; Hanning, Rhona M

    2012-01-01

    Nutrition applications for mobile devices (e.g., personal digital assistants, smartphones) are becoming increasingly accessible and can assist with the difficult task of intake recording for dietary assessment and self-monitoring. This review is a compilation and discussion of research on this tool for dietary intake documentation in healthy populations and those trying to lose weight. The purpose is to compare this tool with conventional methods (e.g., 24-hour recall interviews, paper-based food records). Research databases were searched from January 2000 to April 2011, with the following criteria: healthy or weight loss populations, use of a mobile device nutrition application, and inclusion of at least one of three measures, which were the ability to capture dietary intake in comparison with conventional methods, dietary self-monitoring adherence, and changes in anthropometrics and/or dietary intake. Eighteen studies are discussed. Two application categories were identified: those with which users select food and portion size from databases and those with which users photograph their food. Overall, positive feedback was reported with applications. Both application types had moderate to good correlations for assessing energy and nutrient intakes in comparison with conventional methods. For self-monitoring, applications versus conventional techniques (often paper records) frequently resulted in better self-monitoring adherence, and changes in dietary intake and/or anthropometrics. Nutrition applications for mobile devices have an exciting potential for use in dietetic practice.

  15. Step-wise integration of single-port laparoscopic surgery into routine colorectal surgical practice by use of a surgical glove port.

    Science.gov (United States)

    Hompes, R; Lindsey, I; Jones, O M; Guy, R; Cunningham, C; Mortensen, N J; Cahill, R A

    2011-06-01

    The cost associated with single-port laparoscopic access devices may limit utilisation of single-port laparoscopic surgery by colorectal surgeons. This paper describes a simple and cheap access modality that has facilitated the widespread adoption of single-port technology in our practice both as a stand-alone procedure and as a useful adjunct to traditional multiport techniques. A surgical glove port is constructed by applying a standard glove onto the rim of the wound protector/retractor used during laparoscopic resectional colorectal surgery. To illustrate its usefulness, we present our total experience to date and highlight a selection of patients presenting for a range of elective colorectal surgery procedures. The surgical glove port allowed successful completion of 25 single-port laparoscopic procedures (including laparoscopic adhesiolysis, ileo-rectal anastomosis, right hemicolectomy, total colectomy and low anterior resection) and has been used as an adjunct in over 80 additional multiport procedures (including refashioning of a colorectal anastomosis made after specimen extraction during a standard multiport laparoscopic anterior resection). This simple, efficient device can allow use of single-port laparoscopy in a broader spectrum of patients either in isolation or in combination with multiport surgery than may be otherwise possible for economic reasons. By separating issues of cost from utility, the usefulness of the technical advance inherent within single-port laparoscopy for colorectal surgery can be better appreciated. We endorse the creative innovation inherent in this approach as surgical practice continues to evolve for ever greater patient benefit.

  16. [Hospital-based health technology assessment in France: how to proceed to evaluate innovative medical devices?].

    Science.gov (United States)

    Martelli, N; van den Brink, H; Denies, F; Dervaux, B; Germe, A F; Prognon, P; Pineau, J

    2014-01-01

    Innovative medical devices offer solutions to medical problems and greatly improve patients' outcomes. Like National Health Technology Assessment (HTA) agencies, hospitals face numerous requests for innovative and costly medical devices. To help local decision-makers, different approaches of hospital-based HTA (HB-HTA) have been adopted worldwide. The objective of the present paper is to explore HB-HTA models for adopting innovative medical devices in France and elsewhere. Four different models have been conceptualized: "ambassador" model, "mini-HTA" model, "HTA unit" model and "internal committee". Apparently, "HTA unit" and "internal committee" (or a mixture of both models) are the prevailing HB-HTA models in France. Nevertheless, some weaknesses of these models have been pointed out in previous works. Only few examples involving hospital pharmacists have been found abroad, except in France and in Italy. Finally, the harmonization of the assessment of innovative medical devices in France needs a better understanding of HB-HTA practices. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  17. Peer-assisted teaching of basic surgical skills.

    Science.gov (United States)

    Preece, Ryan; Dickinson, Emily Clare; Sherif, Mohamed; Ibrahim, Yousef; Ninan, Ann Susan; Aildasani, Laxmi; Ahmed, Sartaj; Smith, Philip

    2015-01-01

    Basic surgical skills training is rarely emphasised in undergraduate medical curricula. However, the provision of skills tutorials requires significant commitment from time-constrained surgical faculty. We aimed to determine how a peer-assisted suturing workshop could enhance surgical skills competency among medical students and enthuse them towards a career in surgery. Senior student tutors delivered two suturing workshops to second- and third- year medical students. Suturing performance was assessed before and after teaching in a 10-min suturing exercise (variables measured included number of sutures completed, suture tension, and inter-suture distance). Following the workshop, students completed a questionnaire assessing the effect of the workshop on their suturing technique and their intention to pursue a surgical career. Thirty-five students attended. Eighty-one percent believed their medical school course provided insufficient basic surgical skills training. The mean number of sutures completed post-teaching increased significantly (p teaching, to ± 2.6 mm post-teaching. All students found the teaching environment to be relaxed, and all felt the workshop helped to improve their suturing technique and confidence; 87% found the peer-taught workshop had increased their desire to undertake a career in surgery. Peer-assisted learning suturing workshops can enhance medical students' competence with surgical skills and inspire them towards a career in surgery. With very little staff faculty contribution, it is a cheap and sustainable way to ensure ongoing undergraduate surgical skills exposure.

  18. [Impact of an automated dispensing system for medical devices in cardiac surgery department].

    Science.gov (United States)

    Clou, E; Dompnier, M; Kably, B; Leplay, C; Poupon, E; Archer, V; Paul, M

    2018-01-01

    To secure medical devices' management, the implementation of automated dispensing system in surgical service has been realized. The objective of this study was to evaluate security, organizational and economic impact of installing automated dispensing system for medical devices (ASDM). The implementation took place in a cardiac surgery department. Security impact was assessed by comparing traceability rate of implantable medical devices one year before and one year after installation. Questionnaire on nurses' perception and satisfaction completed this survey. Resupplying costs, stocks' evolution and investments for the implementation of ASDM were the subject of cost-benefit study. After one year, traceability rate is excellent (100%). Nursing staffs were satisfied with 87.5% by this new system. The introduction of ASDM allowed a qualitative and quantitative decrease in stocks, with a reduction of 30% for purchased medical devices and 15% for implantable medical devices in deposit-consignment. Cost-benefit analysis shows a rapid return on investment. Real stock decrease (purchased medical devices) is equivalent to 46.6% of investment. Implementation of ASDM allows to secure storage and dispensing of medical devices. This system has also an important economic impact and appreciated by users. Copyright © 2017 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  19. Virtual reality 3D echocardiography in the assessment of tricuspid valve function after surgical closure of ventricular septal defect

    NARCIS (Netherlands)

    G. Bol-Raap (Goris); A.H.J. Koning (Anton); T.V. Scohy (Thierry); A.D.J. ten Harkel (Arend); F.J. Meijboom (Folkert); A.P. Kappetein (Arie Pieter); P.J. van der Spek (Peter); A.J.J.C. Bogers (Ad)

    2007-01-01

    textabstractBackground. This study was done to investigate the potential additional role of virtual reality, using three-dimensional (3D) echocardiographic holograms, in the postoperative assessment of tricuspid valve function after surgical closure of ventricular septal defect (VSD). Methods. 12

  20. Communication Skills among Surgical Trainees: Perceptions of ...

    African Journals Online (AJOL)

    Objective Communication between the surgeon and the patient is a core clinical skill. The ability to communicate with patients and their family members is very important in the optimum care of the surgical patient. Few studies have assessed communication between surgical trainees and their patients in sub-Saharan Africa.

  1. FY1995 development of a endoscopic surgical system utilizing multi-modal functional images; 1995 nendo tashu kino gazo wo mochiiru teishinshu naishikyo shujutsu system no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-05-01

    The purpose of this study is to develop an endoscope system for neurosurgery that can provide not only conventional endoscopic images but also ultraviolet-visible spectra, fluorescence spectra, near infrared spectra, and ultra-soundimages of tissue aiming for real-time identification of pathological tissue. The system also incorporates surgical manipulator and devices such as micro forceps and laser surgical instruments for endoscopic image guided surgery. Surgical Manipulator should be a high performance and easy to operate surgical instrument as well as conventional surgical tools such as scissors and knife. Since living tissue deforms during surgical operation, pre-operative three dimensional information for registration of pathological tissue should be modified based on information obtained during surgery. Thus surgical manipulator should be operated under guidance of surgeon's observation. Consequently, surgical manipulator should have various types of imaging and measurement devices such as an endoscope and an ultrasound imaging probe at its end effectors. Based on this concept, a prototype of a new multi channel surgical manipulator system CM cube (CM3, Computer aided Micro Multichannel Manipulator) that has various types of imaging and measurement devices such as ultra-violet-visible camera for spectroscopic measurement, ultra-sound imaging probe, three dimensional endoscope, together with micro surgical instruments and laser surgical systems has been developed. Its performance was evaluated through in vitro/in vivo experiments and clinical application. (NEDO)

  2. Exploring Surgeons' Perceptions of the Role of Simulation in Surgical Education: A Needs Assessment

    Directory of Open Access Journals (Sweden)

    Marcia Clark

    2011-11-01

    Full Text Available Introduction: The last two decades have seen the adoption of simulation-based surgical education in various disciplines. The current study’s goal was to perform a needs assessment using the results to inform future curricular planning and needs of surgeons and learners. Methods: A survey was distributed to 26 surgeon educators and interviews were conducted with 8 of these surgeons.  Analysis of survey results included reliability and descriptive statistics. Interviews were analyzed for thematic content with a constant comparison technique, developing coding and categorization of themes. Results: The survey response rate was 81%. The inter-item reliability, according to Cronbach’s alpha was 0.81 with strongest agreement for statements related to learning new skills, training new residents and the positive impact on patient safety and learning.   There was less strong agreement for maintenance of skills, improving team functioning and reducing teaching in the operating room. Interview results confirmed those themes from the survey and highlighted inconsistencies for identified perceived barriers and a focus on acquisition of skills only.  Interview responses specified concerns with integrating simulation into existing curricula and the need for more evaluation as a robust educational strategy. Conclusion: The findings were summarized in four themes: 1 use of simulation, 2 integration into curriculum, 3 leadership, and 4 understanding gaps in simulation use. This study exemplifies a mixed-methods approach to planning a surgical simulation program through a general needs assessment.

  3. Influence of surgical implantation angle of left ventricular assist device outflow graft and management of aortic valve opening on the risk of stroke in heart failure patients

    Science.gov (United States)

    Chivukula, V. Keshav; McGah, Patrick; Prisco, Anthony; Beckman, Jennifer; Mokadam, Nanush; Mahr, Claudius; Aliseda, Alberto

    2016-11-01

    Flow in the aortic vasculature may impact stroke risk in patients with left ventricular assist devices (LVAD) due to severely altered hemodynamics. Patient-specific 3D models of the aortic arch and great vessels were created with an LVAD outflow graft at 45, 60 and 90° from centerline of the ascending aorta, in order to understand the effect of surgical placement on hemodynamics and thrombotic risk. Intermittent aortic valve opening (once every five cardiac cycles) was simulated and the impact of this residual native output investigated for the potential to wash out stagnant flow in the aortic root region. Unsteady CFD simulations with patient-specific boundary conditions were performed. Particle tracking for 10 cardiac cycles was used to determine platelet residence times and shear stress histories. Thrombosis risk was assessed by a combination of Eulerian and Lagrangian metrics and a newly developed thrombogenic potential metric. Results show a strong influence of LVAD outflow graft angle on hemodynamics in the ascending aorta and consequently on stroke risk, with a highly positive impact of aortic valve opening, even at low frequencies. Optimization of LVAD implantation and management strategies based on patient-specific simulations to minimize stroke risk will be presented

  4. Safety, effectiveness and acceptability of the PrePex device for adult male circumcision in Kenya.

    Directory of Open Access Journals (Sweden)

    Paul J Feldblum

    Full Text Available To assess the safety, effectiveness and acceptability of the PrePex device for adult medical male circumcision (MMC in routine service delivery in Kenya.We enrolled 427 men ages 18-49 at one fixed and two outreach clinics. Procedures were performed by trained clinical officers and nurses. The first 50 enrollees were scheduled for six follow-up visits, and remaining men were followed at Days 7 and 42. We recorded adverse events (AEs and time to complete healing, and interviewed men about acceptability and pain.Placement and removal procedures each averaged between 3 and 4 minutes. Self-reported pain was minimal during placement but was fleetingly intense during removal. The rate of moderate/severe AEs was 5.9% overall (95% confidence interval [CI] 3.8%-8.5%, all of which resolved without sequelae. AEs included 5 device displacements, 2 spontaneous foreskin detachments, and 9 cases of insufficient foreskin removal. Surgical completion of MMC was required for 9 men (2.1%. Among the closely monitored first 50 participants, the probability of complete healing by Day 42 was 0.44 (95% CI 0.30-0.58, and 0.90 by Day 56. A large majority of men was favorable about their MMC procedure and would recommend PrePex to friends and family.The PrePex device was effective for MMC in Kenya, and well-accepted. The AE rate was higher than reported for surgical procedures there, or in previous PrePex studies. Healing time is longer than following surgical circumcision. Provider experience and clearer counseling on post-placement and post-removal care should lead to lower AE rates.ClinicalTrials.gov NCT01711411.

  5. Radiological hazard assessment of extracorporeal shock wave lithotripsy devices

    International Nuclear Information System (INIS)

    Sprague, D.D.; Vermeere, W.R.

    1987-01-01

    With the recent introduction of ESWL to the clinical environment, a new health physics challenge has entered the medical consulting area. The x-ray imaging systems used in the devices are of a conventional design, but in an unusual configuration that is difficult to properly assess. The scope of this paper considers specific evaluation problems, and deals with methods developed during experience with 4 units in California. Pertinent regulations are also covered, along with a synopsis of data obtained and ALARA recommendations

  6. Association between surgical indications, operative risk, and clinical outcome in infective endocarditis: a prospective study from the International Collaboration on Endocarditis.

    Science.gov (United States)

    Chu, Vivian H; Park, Lawrence P; Athan, Eugene; Delahaye, Francois; Freiberger, Tomas; Lamas, Cristiane; Miro, Jose M; Mudrick, Daniel W; Strahilevitz, Jacob; Tribouilloy, Christophe; Durante-Mangoni, Emanuele; Pericas, Juan M; Fernández-Hidalgo, Nuria; Nacinovich, Francisco; Rizk, Hussien; Krajinovic, Vladimir; Giannitsioti, Efthymia; Hurley, John P; Hannan, Margaret M; Wang, Andrew

    2015-01-13

    Use of surgery for the treatment of infective endocarditis (IE) as related to surgical indications and operative risk for mortality has not been well defined. The International Collaboration on Endocarditis-PLUS (ICE-PLUS) is a prospective cohort of consecutively enrolled patients with definite IE from 29 centers in 16 countries. We included patients from ICE-PLUS with definite left-sided, non-cardiac device-related IE who were enrolled between September 1, 2008, and December 31, 2012. A total of 1296 patients with left-sided IE were included. Surgical treatment was performed in 57% of the overall cohort and in 76% of patients with a surgical indication. Reasons for nonsurgical treatment included poor prognosis (33.7%), hemodynamic instability (19.8%), death before surgery (23.3%), stroke (22.7%), and sepsis (21%). Among patients with a surgical indication, surgical treatment was independently associated with the presence of severe aortic regurgitation, abscess, embolization before surgical treatment, and transfer from an outside hospital. Variables associated with nonsurgical treatment were a history of moderate/severe liver disease, stroke before surgical decision, and Staphyloccus aureus etiology. The integration of surgical indication, Society of Thoracic Surgeons IE score, and use of surgery was associated with 6-month survival in IE. Surgical decision making in IE is largely consistent with established guidelines, although nearly one quarter of patients with surgical indications do not undergo surgery. Operative risk assessment by Society of Thoracic Surgeons IE score provides prognostic information for survival beyond the operative period. S aureus IE was significantly associated with nonsurgical management. © 2014 American Heart Association, Inc.

  7. Technological aided assessment of the acutely ill patient - The case of postoperative complications

    DEFF Research Database (Denmark)

    Haahr-Raunkjær, C.; Meyhoff, C. S.; Sørensen, H. B.D.

    2017-01-01

    Surgical interventions come with complications and highly reported mortality after major surgery. The mortality may be a result of delayed detection of severe complications due to lower monitoring frequency in the general wards. Several studies have shown that continuous monitoring is superior to....... A few studies indicate that monitoring systems detect deteriorating patients earlier than the nurses, and this was associated with less clinical instability.An important caveat of future devices is to assess their effect in relevant patient populations and not only in healthy test......-subjects. Implementation of novel technologies is expensive although expected to be cost-effective if just few adverse events can be prevented. The future is here with promising devices and the possibility to give an unprecedented precise risk estimation of adverse post-surgical events. Next step is to integrate existing...

  8. Vertical distraction of the severely resorbed mandible - The Groningen Distraction Device

    NARCIS (Netherlands)

    Raghoebar, GM; Heydenrijk, K; Vissink, A

    2000-01-01

    In this paper, both the surgical procedure and the clinical results of a novel distraction device to augment a severely resorbed anterior edentulous mandible are described. The distraction device is non-voluminous, and consists of two distraction screws and one guide screw. Two months after the last

  9. Assessment And Testing of Industrial Devices Robustness Against Cyber Security Attacks

    CERN Document Server

    Tilaro, F

    2011-01-01

    CERN (European Organization for Nuclear Research),like any organization, needs to achieve the conflicting objectives of connecting its operational network to Internet while at the same time keeping its industrial control systems secure from external and internal cyber attacks. With this in mind, the ISA-99[0F1] international cyber security standard has been adopted at CERN as a reference model to define a set of guidelines and security robustness criteria applicable to any network device. Devices robustness represents a key link in the defense-in-depth concept as some attacks will inevitably penetrate security boundaries and thus require further protection measures. When assessing the cyber security robustness of devices we have singled out control system-relevant attack patterns derived from the well-known CAPEC[1F2] classification. Once a vulnerability is identified, it needs to be documented, prioritized and reproduced at will in a dedicated test environment for debugging purposes. CERN - in collaboration ...

  10. Effects of Frequent Glove Change on Outcomes of Orthopaedic Surgical Procedures - A Multicenter Study on Surgical Gloves

    Directory of Open Access Journals (Sweden)

    Nishit Palo

    2017-10-01

    Full Text Available Introduction: Intact surgical gloves are a barrier to microorganisms migration between surgical team members and the patient. The surgical gloves are changed at various junctures but the effects of changing gloves during surgical procedures on various surgical parameters or clinical outcomes are not established. Aim: To determine rationale of glove change during orthopaedic procedures, differences amongst surgical parameters with and without changing the surgical gloves and whether frequent glove change affected surgical parameters or clinical outcomes. Materials and Methods: A prospective multicenter study conducted at three centers from January 2014 to January 2016. A 250 patients were divided into 2 groups (n=125 each in Group 1, surgical team operated with regular changing of gloves. In Group 2, only 1 set of double gloves were worn throughout the procedure. Surgical parameters or clinical outcomes were assessed for both the groups. Statistical analyses included the median, mode, range, Interquartile Range (IQR and sample standard deviation (s and independent-samples t-test. Bacterial counts were expressed as median with (IQR. Results: Surgical Timing Difference was 10 (S.D.- 4.2 minutes more in Group-1 (<0.05, Surgical Cost was higher in Group-1 by Rs.150-450 (<0.05. Outer glove micro-perforation rate was 5.85% and 8.15% in group-1 and 2 respectively with no inner glove perforation or Surgical Site Infections. Outer glove micro perforations were proportional to duration of surgery; operations lasting 120-210 and 61-120 minutes had 66.6% and 37.2% micro perforation rates respectively (p<0.05. Conclusion: Under standard operating conditions, procedures performed without glove change are shorter and cost effective than procedures performed with regular glove change with similar surgical and functional results. Judicious use of surgical gloves is a patient and environment friendly option, thereby reducing the hospital’s biomedical waste load.

  11. [Simulation training in surgical education - application of virtual reality laparoscopic simulators in a surgical skills course].

    Science.gov (United States)

    Lehmann, K S; Gröne, J; Lauscher, J C; Ritz, J-P; Holmer, C; Pohlen, U; Buhr, H-J

    2012-04-01

    Training and simulation are gaining importance in surgical education. Today, virtual reality surgery simulators provide sophisticated laparoscopic training scenarios and offer detailed assessment methods. This also makes simulators interesting for the application in surgical skills courses. The aim of the current study was to assess the suitability of a virtual surgery simulator for training and assessment in an established surgical training course. The study was conducted during the annual "Practical Course for Visceral Surgery" (Warnemuende, Germany). 36 of 108 course participants were assigned at random for the study. Training was conducted in 15 sessions over 5 days with 4 identical virtual surgery simulators (LapSim) and 2 standardised training tasks. The simulator measured 16 individual parameters and calculated 2 scores. Questionnaires were used to assess the test persons' laparoscopic experience, their training situation and the acceptance of the simulator training. Data were analysed with non-parametric tests. A subgroup analysis for laparoscopic experience was conducted in order to assess the simulator's construct validity and assessment capabilities. Median age was 32 (27 - 41) years; median professional experience was 3 (1 - 11) years. Typical laparoscopic learning curves with initial significant improvements and a subsequent plateau phase were measured over 5 days. The individual training sessions exhibited a rhythmic variability in the training results. A shorter night's sleep led to a marked drop in performance. The participants' different experience levels could clearly be discriminated ( ≤ 20 vs. > 20 laparoscopic operations; p ≤ 0.001). The questionnaire showed that the majority of the participants had limited training opportunities in their hospitals. The simulator training was very well accepted. However, the participants severely misjudged the real costs of the simulators that were used. The learning curve on the

  12. American College of Surgeons/Association for Surgical Education medical student simulation-based surgical skills curriculum needs assessment.

    Science.gov (United States)

    Glass, Charity C; Acton, Robert D; Blair, Patrice G; Campbell, Andre R; Deutsch, Ellen S; Jones, Daniel B; Liscum, Kathleen R; Sachdeva, Ajit K; Scott, Daniel J; Yang, Stephen C

    2014-02-01

    Simulation can enhance learning effectiveness, efficiency, and patient safety and is engaging for learners. A survey was conducted of surgical clerkship directors nationally and medical students at 5 medical schools to rank and stratify simulation-based educational topics. Students applying to surgery were compared with others using Wilcoxon's rank-sum tests. Seventy-three of 163 clerkship directors (45%) and 231 of 872 students (26.5%) completed the survey. Of students, 28.6% were applying for surgical residency training. Clerkship directors and students generally agreed on the importance and timing of specific educational topics. Clerkship directors tended to rank basic skills, such as examination skills, higher than medical students. Students ranked procedural skills, such as lumbar puncture, more highly than clerkship directors. Surgery clerkship directors and 4th-year medical students agree substantially about the content of a simulation-based curriculum, although 4th-year medical students recommended that some topics be taught earlier than the clerkship directors recommended. Students planning to apply to surgical residencies did not differ significantly in their scoring from students pursuing nonsurgical specialties. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. The impact of a surgical boot camp on early acquisition of technical and nontechnical skills by novice surgical trainees.

    Science.gov (United States)

    Heskin, Leonie; Mansour, Ehab; Lane, Brian; Kavanagh, Dara; Dicker, Pat; Ryan, Donncha; Gildea-Byrne, Kate; Pawlikowska, Teresa; Tierney, Sean; Traynor, Oscar

    2015-09-01

    Acquisition of skills early in surgical training represents a significant challenge at present because of training time constraints. The aim of this study was to investigate if an intensive surgical boot camp was effective in transferring skills at the beginning of a surgical training program. New core surgical trainees (n = 58) took part in a 5-day boot camp. There were pretest and posttest assessments of knowledge, technical skills, and confidence levels. The boot camp used simulation and senior surgical faculty to teach a defined range of technical and nontechnical skills. The scores for knowledge (53.8% vs 68.4%, P technical skills (35.9% to 60.6% vs 50.6% to 78.2%, P Skills improvements were still present a year later. The 5-day surgical boot camp proved to be an effective way to rapidly acquire surgical knowledge and skills while increasing the confidence levels of trainees. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Blood transfusion knowledge of surgical residents: is an educational intervention effective?

    Science.gov (United States)

    Champion, Caitlin; Saidenberg, Elianna; Lampron, Jacinthe; Pugh, Debra

    2017-04-01

    Evidence-based transfusion education for surgical residents is crucial to improving practice. A pilot study was undertaken to assess the effectiveness of an education module for improving transfusion knowledge among surgical residents. Modules were developed and delivered by experts in surgery and transfusion medicine. They were delivered to residents in their first 2 years of training (Surgical Foundations), and to General Surgery residents across all years of training. Premodule and postmodule and retention knowledge assessments were used to assess efficacy. Median assessment scores for each group were compared using a two-sample Wilcoxon rank-sum analysis. Chi-square tests were used to compare each group's correct response rates for each question across the three tests. Median assessment scores of residents in the Surgical Foundations program improved from a mean of 60% premodule to 80% postmodule and remained at 80% in the retention assessment (p transfusion dose, preoperative blood management, management of reactions, and informed consent (p Transfusion knowledge of surgical residents was improved by a collaborative educational initiative. This could serve as a model for other training programs to improve resident knowledge of evidence-based transfusion practices. The efficacy of such interventions in changing practice remains untested. © 2017 AABB.

  15. Assessment of Current Practice for Tank Testing of Small Marine Energy Devices

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Frigaard, Peter

    Discussion Report. Equitable Testing and Evaluation of Marine Energy Extraction Devices in terms of Performance, Cost and Environmental Impact. The report is a contribution by Aalborg University (AAU) to the deliverable on Assessment of current practice for tank testing of small marine energy...

  16. A prospective single center study to assess the impact of surgical stabilization in patients with rib fracture.

    Science.gov (United States)

    Khandelwal, Gaurav; Mathur, R K; Shukla, Sumit; Maheshwari, Ankur

    2011-01-01

    To compare the intensity of pain and duration of return to normal activity in patients with rib fractures treated with surgical stabilization with plating versus conventional treatment modalities. This study was conducted over a 12 month period. Patients with rib fractures were assessed by numerical pain scale. Patients having pain scale less than 5 were excluded from study. Patients having pain scale of 5 or more than 5 were treated with conventional treatment for next 10 days. On 11th day patients were again assessed by numerical pain scale and patients having score less than 5 were excluded from study. Patients having pain scale of 5, 6, and 7 were treated with conventional treatment and patients having pain scale of 8, 9, and 10 were selected for operative management. Operative and control group were compared on basis of intensity of pain and duration of return to normal activity. Follow up was done on 5, 15, and 30 post operative day. There was less pain in operative group as compared to control group. Mean rib fracture pain in operative group was 9.15, 2.31, 1.12 as compared to 6.25, 5.96, 4.50 in control group on 5, 15 and 30 post operative days. Also there was early return to normal activity in operative group. Surgical stabilization of rib fracture, an underutilized intervention is better than conventional conservative management in terms of both, decrease in intensity of pain and early return to normal activity. Copyright © 2011 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  17. Towed Optical Assessment Device (TOAD) Data to Support Benthic Habitat Mapping since 2001

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Optical validation data were collected using a Tethered Optical Assessment Device (TOAD), an underwater sled equipped with an underwater digital video camera and...

  18. An Observational Assessment of Anesthesia Capacity in Madagascar as a Prerequisite to the Development of a National Surgical Plan.

    Science.gov (United States)

    Baxter, Linden S; Ravelojaona, Vaonandianina A; Rakotoarison, Hasiniaina N; Herbert, Alison; Bruno, Emily; Close, Kristin L; Andean, Vanessa; Andriamanjato, Hery H; Shrime, Mark G; White, Michelle C

    2017-06-01

    The global lack of anesthesia capacity is well described, but country-specific data are needed to provide country-specific solutions. We aimed to assess anesthesia capacity in Madagascar as part of the development of a Ministry of Health national surgical plan. As part of a nationwide surgical safety quality improvement project, we surveyed 19 of 22 regional hospitals, representing surgical facilities caring for 75% of the total population. The assessment was divided into 3 areas: anesthesia workforce density, infrastructure and equipment, and medications. Data were obtained by semistructured interviews with Ministry of Health officials, hospital directors, technical directors, statisticians, pharmacists, and anesthesia providers and through on-site observations. Interview questions were adapted from the World Health Organization Situational Analysis Tool and the World Federation of Societies of Anaesthesiologists International Standards for Safe Practice of Anaesthesia. Additional data on workforce density were collected from the 3 remaining regions so that workforce density data are representative of all 22 regions. Anesthesia physician workforce density is 0.26 per 100,000 population and 0.19 per 100,000 outside of the capital region. Less than 50% of hospitals surveyed reported having a reliable electricity and oxygen supply. The majority of anesthesia providers work without pulse oximetry (52%) or a functioning vaporizer (52%). All the hospitals surveyed had very basic pediatric supplies, and none had a pediatric pulse oximetry probe. Ketamine is universally available but more than 50% of hospitals lack access to opioids. None of the 19 regional hospitals surveyed was able to completely meet the World Federation of Societies of Anaesthesiologists' standards for monitoring. Improving anesthesia care is complex. Capacity assessment is a first step that would enable progress to be tracked against specific targets. In Madagascar, scale-up of the anesthesia

  19. Improving risk assessment of color additives in medical device polymers.

    Science.gov (United States)

    Chandrasekar, Vaishnavi; Janes, Dustin W; Forrey, Christopher; Saylor, David M; Bajaj, Akhil; Duncan, Timothy V; Zheng, Jiwen; Riaz Ahmed, Kausar B; Casey, Brendan J

    2018-01-01

    Many polymeric medical device materials contain color additives which could lead to adverse health effects. The potential health risk of color additives may be assessed by comparing the amount of color additive released over time to levels deemed to be safe based on available toxicity data. We propose a conservative model for exposure that requires only the diffusion coefficient of the additive in the polymer matrix, D, to be specified. The model is applied here using a model polymer (poly(ether-block-amide), PEBAX 2533) and color additive (quinizarin blue) system. Sorption experiments performed in an aqueous dispersion of quinizarin blue (QB) into neat PEBAX yielded a diffusivity D = 4.8 × 10 -10 cm 2  s -1 , and solubility S = 0.32 wt %. On the basis of these measurements, we validated the model by comparing predictions to the leaching profile of QB from a PEBAX matrix into physiologically representative media. Toxicity data are not available to estimate a safe level of exposure to QB, as a result, we used a Threshold of Toxicological Concern (TTC) value for QB of 90 µg/adult/day. Because only 30% of the QB is released in the first day of leaching for our film thickness and calculated D, we demonstrate that a device may contain significantly more color additive than the TTC value without giving rise to a toxicological concern. The findings suggest that an initial screening-level risk assessment of color additives and other potentially toxic compounds found in device polymers can be improved. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 310-319, 2018. © 2017 Wiley Periodicals, Inc.

  20. Can skills assessment on a virtual reality trainer predict a surgical trainee's talent in laparoscopic surgery?

    Science.gov (United States)

    Rosenthal, R; Gantert, W A; Scheidegger, D; Oertli, D

    2006-08-01

    A number of studies have investigated several aspects of feasibility and validity of performance assessments with virtual reality surgical simulators. However, the validity of performance assessments is limited by the reliability of such measurements, and some issues of reliability still need to be addressed. This study aimed to evaluate the hypothesis that test subjects show logarithmic performance curves on repetitive trials for a component task of laparoscopic cholecystectomy on a virtual reality simulator, and that interindividual differences in performance after considerable training are significant. According to kinesiologic theory, logarithmic performance curves are expected and an individual's learning capacity for a specific task can be extrapolated, allowing quantification of a person's innate ability to develop task-specific skills. In this study, 20 medical students at the University of Basel Medical School performed five trials of a standardized task on the LS 500 virtual reality simulator for laparoscopic surgery. Task completion time, number of errors, economy of instrument movements, and maximum speed of instrument movements were measured. The hypothesis was confirmed by the fact that the performance curves for some of the simulator measurements were very close to logarithmic curves, and there were significant interindividual differences in performance at the end of the repetitive trials. Assessment of perceptual motor skills and the innate ability of an individual with no prior experience in laparoscopic surgery to develop such skills using the LS 500 VR surgical simulator is feasible and reliable.

  1. A quantitative assessment of the efficacy of surgical and N95 masks to filter influenza virus in patients with acute influenza infection.

    Science.gov (United States)

    Johnson, D F; Druce, J D; Birch, C; Grayson, M L

    2009-07-15

    We assessed the in vivo efficacy of surgical and N95 (respirator) masks to filter reverse transcription-polymerase chain reaction (RT-PCR)-detectable virus when worn correctly by patients with laboratory-confirmed acute influenza. Of 26 patients with a clinical diagnosis of influenza, 19 had the diagnosis confirmed by RT-PCR, and 9 went on to complete the study. Surgical and N95 masks were equally effective in preventing the spread of PCR-detectable influenza.

  2. Surgical simulation in orthopaedic skills training.

    Science.gov (United States)

    Atesok, Kivanc; Mabrey, Jay D; Jazrawi, Laith M; Egol, Kenneth A

    2012-07-01

    Mastering rapidly evolving orthopaedic surgical techniques requires a lengthy period of training. Current work-hour restrictions and cost pressures force trainees to face the challenge of acquiring more complex surgical skills in a shorter amount of time. As a result, alternative methods to improve the surgical skills of orthopaedic trainees outside the operating room have been developed. These methods include hands-on training in a laboratory setting using synthetic bones or cadaver models as well as software tools and computerized simulators that enable trainees to plan and simulate orthopaedic operations in a three-dimensional virtual environment. Laboratory-based training offers potential benefits in the development of basic surgical skills, such as using surgical tools and implants appropriately, achieving competency in procedures that have a steep learning curve, and assessing already acquired skills while minimizing concerns for patient safety, operating room time, and financial constraints. Current evidence supporting the educational advantages of surgical simulation in orthopaedic skills training is limited. Despite this, positive effects on the overall education of orthopaedic residents, and on maintaining the proficiency of practicing orthopaedic surgeons, are anticipated.

  3. Randomized controlled trial in rural Ethiopia to assess a portable water treatment device.

    Science.gov (United States)

    Boisson, Sophie; Schmidt, Wolf-Peter; Berhanu, Tsegahiwot; Gezahegn, Henock; Clasen, Thomas

    2009-08-01

    We conducted a randomized controlled trial to assess the Lifestraw Personal pipe-style water treatment device among a rural population in Ethiopia. A total of 313 households (including 1516 persons) were randomly assigned either to an intervention group in which each householder received a Lifestraw Personal or a control. Households were visited fortnightly over a five-month intervention period and asked to report any episode of diarrhea during the previous week. A random sample of 160 devices was tested each month to assess the presence of thermotolerant coliforms (TTC) and residual iodine in treated water and to measure flow rate under simulated use. Members of the intervention group had 25% fewer weeks with diarrhea than those of the control group (longitudinal prevalence ratio = 0.75; 95% CI 0.60; 0.95). All 718 filtered water samples were free of TTC, were free of detectable iodine disinfectant, and showed a constant flow rate over time. After the five-month intervention period, 34% of participants reported use of device in the preceding week and 13% reported consistent use. While the device was associated with a 25% reduction in longitudinal prevalence of diarrhea, low levels of use suggest that much of this effect is likely to be attributable to reporting bias that is common in open trials with nonobjective outcomes.

  4. Application of handheld devices to field research among underserved construction worker populations: a workplace health assessment pilot study

    Directory of Open Access Journals (Sweden)

    Fleming Lora E

    2011-04-01

    Full Text Available Abstract Background Novel low-cost approaches for conducting rapid health assessments and health promotion interventions among underserved worker groups are needed. Recruitment and participation of construction workers is particularly challenging due to their often transient periods of work at any one construction site, and their limited time during work to participate in such studies. In the present methodology report, we discuss the experience, advantages and disadvantages of using touch screen handheld devices for the collection of field data from a largely underserved worker population. Methods In March 2010, a workplace-centered pilot study to examine the feasibility of using a handheld personal device for the rapid health assessment of construction workers in two South Florida Construction sites was undertaken. A 45-item survey instrument, including health-related questions on tobacco exposure, workplace safety practices, musculoskeletal disorders and health symptoms, was programmed onto Apple iPod Touch® devices. Language sensitive (English and Spanish recruitment scripts, verbal consent forms, and survey questions were all preloaded onto the handheld devices. The experience (time to survey administration and capital cost of the handheld administration method was recorded and compared to approaches available in the extant literature. Results Construction workers were very receptive to the recruitment, interview and assessment processes conducted through the handheld devices. Some workers even welcomed the opportunity to complete the questionnaire themselves using the touch screen handheld device. A list of advantages and disadvantages emerged from this experience that may be useful in the rapid health assessment of underserved populations working in a variety of environmental and occupational health settings. Conclusions Handheld devices, which are relatively inexpensive, minimize survey response error, and allow for easy storage of data

  5. Application of handheld devices to field research among underserved construction worker populations: a workplace health assessment pilot study.

    Science.gov (United States)

    Caban-Martinez, Alberto J; Clarke, Tainya C; Davila, Evelyn P; Fleming, Lora E; Lee, David J

    2011-04-01

    Novel low-cost approaches for conducting rapid health assessments and health promotion interventions among underserved worker groups are needed. Recruitment and participation of construction workers is particularly challenging due to their often transient periods of work at any one construction site, and their limited time during work to participate in such studies. In the present methodology report, we discuss the experience, advantages and disadvantages of using touch screen handheld devices for the collection of field data from a largely underserved worker population. In March 2010, a workplace-centered pilot study to examine the feasibility of using a handheld personal device for the rapid health assessment of construction workers in two South Florida Construction sites was undertaken. A 45-item survey instrument, including health-related questions on tobacco exposure, workplace safety practices, musculoskeletal disorders and health symptoms, was programmed onto Apple iPod Touch® devices. Language sensitive (English and Spanish) recruitment scripts, verbal consent forms, and survey questions were all preloaded onto the handheld devices. The experience (time to survey administration and capital cost) of the handheld administration method was recorded and compared to approaches available in the extant literature. Construction workers were very receptive to the recruitment, interview and assessment processes conducted through the handheld devices. Some workers even welcomed the opportunity to complete the questionnaire themselves using the touch screen handheld device. A list of advantages and disadvantages emerged from this experience that may be useful in the rapid health assessment of underserved populations working in a variety of environmental and occupational health settings. Handheld devices, which are relatively inexpensive, minimize survey response error, and allow for easy storage of data. These technological research modalities are useful in the

  6. Assessment of a portable device for the quantitative measurement of ankle joint stiffness in spastic individuals

    DEFF Research Database (Denmark)

    Lorentzen, Jakob; Grey, Michael J; Geertsen, Svend Sparre

    2012-01-01

    was measured with the portable device and a stationary torque motor. Inter- and intra-rater reliability was assessed with the intra-class correlation coefficient (ICC). RESULTS: Stiffness measures with the portable and stationary devices were significantly correlated for controls and MS participants (p...

  7. Ready for OR or not? Human reader supplements Eyesi scoring in cataract surgical skills assessment

    Directory of Open Access Journals (Sweden)

    Selvander M

    2013-10-01

    Full Text Available Madeleine Selvander,1,2 Peter Åsman11Department of Clinical Sciences, Malmö: Ophthalmology, Lund University, Malmö, Sweden; 2Practicum Clinical Skills Centre, Skåne University Hospital, Malmö, SwedenPurpose: To compare the internal computer-based scoring with human-based video scoring of cataract modules in the Eyesi virtual reality intraocular surgical simulator, a comparative case series was conducted at the Department of Clinical Sciences – Ophthalmology, Lund University, Skåne University Hospital, Malmö, Sweden.Methods: Seven cataract surgeons and 17 medical students performed one video-recorded trial with each of the capsulorhexis, hydromaneuvers, and phacoemulsification divide-and-conquer modules. For each module, the simulator calculated an overall score for the performance ranging from 0 to 100. Two experienced masked cataract surgeons analyzed each video using the Objective Structured Assessment of Cataract Surgical Skill (OSACSS for individual models and modified Objective Structured Assessment of Surgical Skills (OSATS for all three modules together. The average of the two assessors' scores for each tool was used as the video-based performance score. The ability to discriminate surgeons from naive individuals using the simulator score and the video score, respectively, was compared using receiver operating characteristic (ROC curves.Results: The ROC areas for simulator score did not differ from 0.5 (random for hydromaneuvers and phacoemulsification modules, yielding unacceptably poor discrimination. OSACSS video scores all showed good ROC areas significantly different from 0.5. The OSACSS video score was also superior compared to the simulator score for the phacoemulsification procedure: ROC area 0.945 vs 0.664 for simulator score (P = 0.010. Corresponding values for capsulorhexis were 0.887 vs 0.761 (P = 0.056 and for hydromaneuvers 0.817 vs 0.571 (P = 0.052 for the video scores and simulator scores, respectively.The ROC

  8. Computer-based laparoscopic and robotic surgical simulators: performance characteristics and perceptions of new users.

    Science.gov (United States)

    Lin, David W; Romanelli, John R; Kuhn, Jay N; Thompson, Renee E; Bush, Ron W; Seymour, Neal E

    2009-01-01

    This study aimed to define perceptions of the need and the value of new simulation devices for laparoscopic and robot-assisted surgery. The initial experience of surgeons using both robotic and nonrobotic laparoscopic simulators to perform an advanced laparoscopic skill was evaluated. At the 2006 Society of American Gastroesophageal Surgeons (SAGES) meeting, 63 Learning Center attendees used a new virtual reality robotic surgery simulator (SEP Robot) and either a computer-enhanced laparoscopic simulator (ProMIS) or a virtual reality simulator (SurgicalSIM). Demographic and training data were collected by an intake survey. Subjects then were assessed during one iteration of laparoscopic suturing and knot-tying on the SEP Robot and either the ProMIS or the SurgicalSIM. A posttask survey determined users' impressions of task realism, interface quality, and educational value. Performance data were collected and comparisons made between user-defined groups, different simulation platforms, and posttask survey responses. The task completion rate was significantly greater for experts than for nonexperts on the virtual reality platforms (SurgicalSIM: 100% vs 36%; SEP Robot: 93% vs 63%; p platforms, whereas simulator metrics best discriminated expertise for the videoscopic platform. Similar comparisons for the virtual reality platforms were not feasible because of the low task completion rate for nonexperts. The added degrees of freedom associated with the robotic surgical simulator instruments facilitated completion of the task by nonexperts. All platforms were perceived as effective training tools.

  9. Residual Isocyanates in Medical Devices and Products: A Qualitative and Quantitative Assessment

    Directory of Open Access Journals (Sweden)

    Gillian Franklin

    2016-01-01

    Full Text Available We conducted a pilot qualitative and quantitative assessment of residual isocyanates and their potential initial exposures in neonates, as little is known about their contact effect. After a neonatal intensive care unit (NICU stockroom inventory, polyurethane (PU and PU foam (PUF devices and products were qualitatively evaluated for residual isocyanates using Surface SWYPE ™ . Those containing isocyanates were quantitatively tested for methylene diphenyl diisocyanate (MDI species, using UPLC-UV-MS/MS method. Ten of 37 products and devices tested, indicated both free and bound residual surface isocyanates; PU/PUF pieces contained aromatic isocyanates; one product contained aliphatic isocyanates. Overall, quantified mean MDI concentrations were low (4,4‘-MDI = 0.52 to 140.1 pg/mg and (2,4‘-MDI = 0.01 to 4.48 pg/mg. The 4,4‘-MDI species had the highest measured concentration (280 pg/mg. Commonly used medical devices/products contain low, but measurable concentrations of residual isocyanates. Quantifying other isocyanate species and neonatal skin exposure to isocyanates from these devices and products requires further investigation.

  10. Informed consent for medical photography in Nigerian surgical ...

    African Journals Online (AJOL)

    Background: The aim of this study is to assess the current practice of informed consent for medical photography in the Nigerian surgical practice and how it compares to international best practices. Methods: Self-administered questionnaires were distributed to consenting surgeons attending two major surgical conferences.

  11. Radiographic Assessment of Bone Formation Using rhBMP2 at Maxillary Periapical Surgical Defects: A Case Series.

    Science.gov (United States)

    Kumar, M Siva; Kumar, M Hari; Vishalakshi, K; Sabitha, H

    2016-04-01

    Periapical cysts are the most common inflammatory odontogenic cysts arising from untreated dental caries with pulp necrosis and periapical infection. The choice of treatment is often influenced by various factors like size, extension of the lesion, proximity to vital structures, systemic condition and compliance of the patient too. The treatment protocol for management of periapical cysts is still under discussion and options vary from conservative treatment by means of endodontic technique to surgical treatment like decompression or a marsupialisation or even to enucleation. Large bony defect secondary to periapical surgery compromising the tooth integrity often requires bone graft to enhance bone formation and thus restoring function at the earliest. The present case series included 10 patients who had established periapical pathology secondary to history of trauma on upper anterior teeth as well patients with history of carious teeth with an apparent failure in root canal therapy. All ten patients were treated with cyst enucleation and apiceotomy along with 1.4cc Recombinant Human Bone Morphogenetic Protein-2 soaked Absorbable Collagen Sponge implantation at surgical defect. Radiographs and clinical examinations were done upto 3 months to evaluate healing. Radiographic and clinical assessments revealed bone regeneration and restoration of the maxillary surgical defects in all 10 patients. No evidence of graft failure was noted. The Recombinant Human Bone Morphogenetic Protein-2 soaked Absorbable Collagen Sponge carrier is thus proved to be a viable option for the treatment of maxillary periapical surgical defects.

  12. Review of influential articles in surgical education: 2002-2012.

    Science.gov (United States)

    Wohlauer, Max V; George, Brian; Lawrence, Peter F; Pugh, Carla M; Van Eaton, Erik G; Darosa, Debra

    2013-06-01

    Exploring the trends in surgical education research offers insight into concerns, developments, and questions researchers are exploring that are relevant to teaching and learning in surgical specialties. We conducted a review of the surgical education literature published between 2002 and 2012. The purpose was 2-fold: to provide an overview of the most frequently cited articles in the field of surgical education during the last decade and to describe the study designs and themes featured in these articles. Articles were identified through Web of Science by using "surgical education" and "English language" as search terms. Using a feature in Web of Science, we tracked the number of citations of any publication. Of the 800 articles produced by the initial search, we initially selected 23 articles with 45 or more citations, and ultimately chose the 20 articles that were most frequently cited for our analysis. Analysis of the most frequently cited articles published in US journals between the years 2002-2012 identified 7 research themes and presented them in order of frequency with which they appear: use of simulation, issues in student/resident assessment, specialty choice, patient safety, team training, clinical competence assessment, and teaching the clinical sciences, with surgical simulation being the central theme. Researchers primarily used descriptive methods. Popular themes in surgical education research illuminate the information needs of surgical educators as well as topics of high interest to the surgical community.

  13. Current state of micro-robots/devices as substitutes for screening colonoscopy: assessment based on technology readiness levels.

    Science.gov (United States)

    Tapia-Siles, Silvia C; Coleman, Stuart; Cuschieri, Alfred

    2016-02-01

    Previous reports have described several candidates, which have the potential to replace colonoscopy, but to date, there is still no device capable of fully replacing flexible colonoscopy in the management of colonic disorders and for mass adult population screening for asymptomatic colorectal cancer. NASA developed the TRL methodology to describe and define the stages of development before use and marketing of any device. The definitions of the TRLS used in the present review are those formulated by "The US Department of Defense Technology Readiness Assessment Guidance" but adapted to micro-robots for colonoscopy. All the devices included are reported in scientific literature. They were identified by a systematic search in Web of Science, PubMed and IEEE Xplore amongst other sources. Devices that clearly lack the potential for full replacement of flexible colonoscopy were excluded. The technological salient features of all the devices included for assessment are described briefly, with particular focus on device propulsion. The devices are classified according to the TRL criteria based on the reported information. An analysis is next undertaken of the characteristics and salient features of the devices included in the review: wireless/tethered devices, data storage-transmission and navigation, additional functionality, residual technology challenges and clinical and socio-economical needs. Few devices currently possess the required functionality and performance to replace the conventional colonoscopy. The requirements, including functionalities which favour the development of a micro-robot platform to replace colonoscopy, are highlighted.

  14. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips.

    Science.gov (United States)

    Gill, Amreeta; Shellock, Frank G

    2012-01-09

    Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC) and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC) that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information) among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants) underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration). Heating was not substantial (highest temperature change, ≤ 1.6°C). Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants.

  15. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips

    Directory of Open Access Journals (Sweden)

    Gill Amreeta

    2012-01-01

    Full Text Available Abstract Purpose Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. Methods A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Results Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration. Heating was not substantial (highest temperature change, ≤ 1.6°C. Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. Conclusions The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants.

  16. Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips

    Science.gov (United States)

    2012-01-01

    Purpose Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts. Methods A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC) and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC) that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information) among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants) underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences. Results Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration). Heating was not substantial (highest temperature change, ≤ 1.6°C). Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant. Conclusions The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants. PMID:22230200

  17. Ex Vivo (Fluorescence) Confocal Microscopy in Surgical Pathology: State of the Art.

    Science.gov (United States)

    Ragazzi, Moira; Longo, Caterina; Piana, Simonetta

    2016-05-01

    First developed in 1957, confocal microscopy is a powerful imaging tool that can be used to obtain near real-time reflected light images of untreated human tissue with nearly histologic resolution. Besides its research applications, in the last decades, confocal microscopy technology has been proposed as a useful device to improve clinical diagnosis, especially in ophthalmology, dermatology, and endomicroscopy settings, thanks to advances in instrument development. Compared with the wider use of the in vivo tissue assessment, ex vivo applications of confocal microscopy are not fully explored. A comprehensive review of the current literature was performed here, focusing on the reliable applications of ex vivo confocal microscopy in surgical pathology and on some potential evolutions of this new technique from pathologists' viewpoint.

  18. Single incision device (TVT Secur) versus retropubic tension-free vaginal tape device (TVT) for the management of stress urinary incontinence in women: a randomized clinical trial.

    Science.gov (United States)

    Ross, Sue; Tang, Selphee; Schulz, Jane; Murphy, Magnus; Goncalves, Jose; Kaye, Stephen; Dederer, Lorel; Robert, Magali

    2014-12-22

    In 2006, Ethicon Inc. introduced a new minimally invasive single incision sling device for the surgical treatment of stress urinary incontinence, the Gynecare TVT Secur®. For device licensing, no new evidence of TVT Secur efficacy and safety was needed: rather evidence was provided of the long-term follow-up of patients who had a procedure using a predecate retropubic tension-free vaginal tape device. Before adopting TVT Secur into our routine clinical practice, we decided to evaluate it. The objective of our Canadian multi-centre pragmatic randomized controlled trial was to compare the effectiveness of the new single-incision device, TVT Secur, to the established TVT device, in terms of objective cure of stress urinary incontinence (SUI) at 12 months postoperatively. Other outcomes included: complications, symptoms, and incontinence-related quality of life. The sample size estimate for our trial was 300, but the trial stopped early because of poor recruitment. 74 women participated (40 allocated to TVT Secur, 34 to TVT). At 12 months postoperatively, 27/33(82%) of TVT Secur group were cured, compared with 25/28(89%) of the TVT group (relative risk 0.92, 95% confidence interval 0.75 to 1.13, p=0.49). Most women reported little or no SUI symptoms (35/37(95%) vs 29/30(97%), >0.999). Quality of life improved significantly from baseline for both groups (IIQ-7 mean change -25 for both groups) but did not differ between groups (p=0.880). Our small randomized trial did not find statistically significant differences in outcomes between women allocated to the TVT Secur device versus those allocated to the TVT device for stress urinary incontinence. Despite the discontinuation of TVT Secur in March 2013 for commercial reasons, the importance of our study lies in making evidence available for the many women who had a TVT Secur device implanted and their physicians who may be considering alternative treatments. Our experience illustrates the difficulty of undertaking research

  19. Assessing subacute mild traumatic brain injury with a portable virtual reality balance device.

    Science.gov (United States)

    Wright, W Geoffrey; McDevitt, Jane; Tierney, Ryan; Haran, F Jay; Appiah-Kubi, Kwadwo Osei; Dumont, Alex

    2017-07-01

    Balance impairment is a common sensorimotor symptom in mild traumatic brain injury (mTBI). We designed an affordable, portable virtual reality (VR)-based balance screening device (Virtual Environment TBI Screen [VETS]), which will be validated relative to the Neurocom Sensory Organization Test (SOT) to determine if it can replace commonly used postural assessments. This preliminary study examines healthy adults (n = 56) and adults with mTBI (n = 11). Participants performed six upright postural tasks on the VETS and the SOT. Analysis of variance was used to determine between-group differences. Pearson's correlations were used to establish construct validity. Known-groups approach was used to establish classification accuracy. The mTBI cohort performed significantly worse than the healthy cohort on the new device (p = 0.001). The new device has 91.0% accuracy and an ROC curve with a significant area-under-the-curve (AUC = 0.865, p virtual reality can be economically integrated into the clinical setting for easy testing of postural control in neurologically impaired populations. Tailoring postural assessments to include tasks that rely on visual and vestibular integration will increase the accuracy of detecting balance impairment following mild traumatic brain injury.

  20. Surgical strategies in childhood craniopharyngioma

    Directory of Open Access Journals (Sweden)

    Jörg eFlitsch

    2011-12-01

    Full Text Available Craniopharyngiomas are biologically benign lesions (WHO Grade 1 of the sellar and suprasellar region, associated with a serious morbidity. About 50% of these tumors become clinically apparent during childhood. Clinical symptoms include headaches, chiasm syndrome, hydrocephalus, pituitary insufficiencies, and obesity. Growth arrest is a typical symptom in children. The treatment of craniopharyngiomas includes surgery as well as radiotherapy. The goal of surgery varies according to the tumor location and extension and may range from complete resection to biopsy. Surgical complications are well known and cause constant evaluation of surgical strategies. Diencephalic obesity is related to surgical manipulation of hypothalamic tissue. Therefore, a classification system for craniopharyngiomas based on preoperative MRI is suggested by the authors, which may help assess the surgical risk. Recurrences are frequent in craniopharyngiomas, even after complete or gross-total resection. Radiotherapy is therefore recommended to patients with incomplete resections. However, the ideal time for radiotherapy after surgery is under discussion.The treatment of craniopharyngiomas requires an interdisciplinary and multimodal approach. Each patient should receive an individually tailored treatment. Surgically, different approaches as well as different degrees of resection can be considered, depending on tumor location and tumor extension.

  1. 3D Surgical Simulation

    Science.gov (United States)

    Cevidanes, Lucia; Tucker, Scott; Styner, Martin; Kim, Hyungmin; Chapuis, Jonas; Reyes, Mauricio; Proffit, William; Turvey, Timothy; Jaskolka, Michael

    2009-01-01

    This paper discusses the development of methods for computer-aided jaw surgery. Computer-aided jaw surgery allows us to incorporate the high level of precision necessary for transferring virtual plans into the operating room. We also present a complete computer-aided surgery (CAS) system developed in close collaboration with surgeons. Surgery planning and simulation include construction of 3D surface models from Cone-beam CT (CBCT), dynamic cephalometry, semi-automatic mirroring, interactive cutting of bone and bony segment repositioning. A virtual setup can be used to manufacture positioning splints for intra-operative guidance. The system provides further intra-operative assistance with the help of a computer display showing jaw positions and 3D positioning guides updated in real-time during the surgical procedure. The CAS system aids in dealing with complex cases with benefits for the patient, with surgical practice, and for orthodontic finishing. Advanced software tools for diagnosis and treatment planning allow preparation of detailed operative plans, osteotomy repositioning, bone reconstructions, surgical resident training and assessing the difficulties of the surgical procedures prior to the surgery. CAS has the potential to make the elaboration of the surgical plan a more flexible process, increase the level of detail and accuracy of the plan, yield higher operative precision and control, and enhance documentation of cases. Supported by NIDCR DE017727, and DE018962 PMID:20816308

  2. Three-dimensional surgical simulation.

    Science.gov (United States)

    Cevidanes, Lucia H C; Tucker, Scott; Styner, Martin; Kim, Hyungmin; Chapuis, Jonas; Reyes, Mauricio; Proffit, William; Turvey, Timothy; Jaskolka, Michael

    2010-09-01

    In this article, we discuss the development of methods for computer-aided jaw surgery, which allows us to incorporate the high level of precision necessary for transferring virtual plans into the operating room. We also present a complete computer-aided surgery system developed in close collaboration with surgeons. Surgery planning and simulation include construction of 3-dimensional surface models from cone-beam computed tomography, dynamic cephalometry, semiautomatic mirroring, interactive cutting of bone, and bony segment repositioning. A virtual setup can be used to manufacture positioning splints for intraoperative guidance. The system provides further intraoperative assistance with a computer display showing jaw positions and 3-dimensional positioning guides updated in real time during the surgical procedure. The computer-aided surgery system aids in dealing with complex cases with benefits for the patient, with surgical practice, and for orthodontic finishing. Advanced software tools for diagnosis and treatment planning allow preparation of detailed operative plans, osteotomy repositioning, bone reconstructions, surgical resident training, and assessing the difficulties of the surgical procedures before the surgery. Computer-aided surgery can make the elaboration of the surgical plan a more flexible process, increase the level of detail and accuracy of the plan, yield higher operative precision and control, and enhance documentation of cases. 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  3. Assessment of the changes in quality of life of patients with class II and III deformities during and after orthodontic-surgical treatment.

    Science.gov (United States)

    Baherimoghaddam, T; Tabrizi, R; Naseri, N; Pouzesh, A; Oshagh, M; Torkan, S

    2016-04-01

    The aim of this longitudinal study was to assess and compare the oral health-related quality of life (OHRQoL) of patients with class II and III deformities during and after orthodontic-surgical treatment. Thirty class III and 28 class II patients were evaluated at baseline (T0), just prior to surgery (T1), at 6 months after surgery (T2), and at 12 months after debonding (T3). OHRQoL was assessed using the Oral Health Impact Profile (OHIP-14). Friedman two-way analysis of variance and the Wilcoxon signed-rank test were performed to compare the relative changes in OHRQoL during treatment. Significant changes in the overall OHIP-14 scores were observed during and after orthodontic-surgical treatment in both groups. During the pre-surgical stage, psychological discomfort and psychological disability decreased in class III patients, and class II patients experienced a significant deterioration in psychological discomfort during the same period. Six months after surgery, patients in both groups showed improvements in psychological discomfort, social disability, and handicap. Physical disability and functional limitation showed further improvement at 12 months after debonding in class II patients. This study reaffirms that orthodontic-surgical treatment has a significant effect on the OHRQoL of class III and class II patients. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. Non-surgical radiofrequency facelift.

    Science.gov (United States)

    Narins, David J; Narins, Rhoda S

    2003-10-01

    There has been considerable interest in using non-ablative methods to rejuvenate the skin. The ThermaCool TC (Thermage Inc.) is a radiofrequency (RF) device that has been introduced to induce tightening of the address the problem of skin via a uniform volumetric heating into the deep dermis tightening, resulting in a 'non-surgical facelift'. Radiofrequency produces a uniform volumetric heating into the deep dermis. Twenty treatment areas in 17 patients were treated to evaluate the efficacy and safety of RF treatment to the brow and jowls. The technique was found to produce gradual tightening in most patients, and there were no adverse effects.

  5. Clinical Assessment of Fluid Balance is Incomplete for Colorectal Surgical Patients

    DEFF Research Database (Denmark)

    Tolstrup, J; Brandstrup, B

    2015-01-01

    BACKGROUND AND AIMS: Fluid balance for the surgical patient has been proven very important for the postoperative outcome and development of complications. The aim of this study was to evaluate, for the first time in modern times, the accordance between nurse-based fluid charting (cumulated fluid...... surgery were included. Cumulated fluid balance and body weight change were charted preoperatively and daily at the same time during a postoperative period of 6 days. Differences were calculated by subtracting cumulated fluid balance from body weight change (1 g = 1 mL), and agreement was assessed...... by making Bland-Altman plots as well as Pearson correlations. RESULTS: From day 1 to 4, the mean difference between cumulated fluid balance and body weight change was below 0.4 kg/L. On day 5 and 6, the discrepancies increased with mean differences of, respectively, 1.2 kg/L (p 

  6. Non-Exposure, Device-Assisted Endoscopic Full-thickness Resection.

    Science.gov (United States)

    Bauder, Markus; Schmidt, Arthur; Caca, Karel

    2016-04-01

    Recent developments have expanded the frontier of interventional endoscopy toward more extended resections following surgical principles. This article presents two new device-assisted techniques for endoscopic full-thickness resection in the upper and lower gastrointestinal tract. Both methods are nonexposure techniques avoiding exposure of gastrointestinal contents to the peritoneal cavity by a "close first-cut later" principle. The full-thickness resection device is a novel over-the-scope device designed for clip-assisted full-thickness resection of colorectal lesions. Endoscopic full-thickness resection of gastric subepithelial tumors can be performed after placing transmural sutures underneath the tumor with a suturing device originally designed for endoscopic antireflux therapy. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. A cross-sectional survey of essential surgical capacity in Somalia.

    Science.gov (United States)

    Elkheir, Natalie; Sharma, Akshay; Cherian, Meena; Saleh, Omar Abdelrahman; Everard, Marthe; Popal, Ghulam Rabani; Ibrahim, Abdi Awad

    2014-05-07

    To assess life-saving and disability-preventing surgical services (including emergency, trauma, obstetrics, anaesthesia) of health facilities in Somalia and to assist in the planning of strategies for strengthening surgical care systems. Cross-sectional survey. Health facilities in all 3 administrative zones of Somalia; northwest Somalia (NWS), known as Somaliland; northeast Somalia (NES), known as Puntland; and south/central Somalia (SCS). 14 health facilities. The WHO Tool for Situational Analysis to Assess Emergency and Essential Surgical Care was employed to capture a health facility's capacity to deliver surgical and anaesthesia services by investigating four categories of data: infrastructure, human resources, interventions available and equipment. The 14 facilities surveyed in Somalia represent 10 of the 18 districts throughout the country. The facilities serve an average patient population of 331 250 people, and 12 of the 14 identify as hospitals. While major surgical procedures were provided at many facilities (caesarean section, laparotomy, appendicectomy, etc), only 22% had fully available oxygen access, 50% fully available electricity and less than 30% had any management guidelines for emergency and surgical care. Furthermore, only 36% were able to provide general anaesthesia inhalation due to lack of skills, supplies and equipment. Basic supplies for airway management and the prevention of infection transmission were severely lacking in most facilities. According to the results of the WHO Tool for Situational Analysis to Assess Emergency and Essential Surgical Care survey, there exist significant gaps in the capacity of emergency and essential surgical services in Somalia including inadequacies in essential equipment, service provision and infrastructure. The information provided by the WHO tool can serve as a basis for evidence-based decisions on country-level policy regarding the allocation of resources and provision of emergency and essential

  8. Patient satisfaction and quality of surgical care in US hospitals.

    Science.gov (United States)

    Tsai, Thomas C; Orav, E John; Jha, Ashish K

    2015-01-01

    The relationship between patient satisfaction and surgical quality is unclear for US hospitals. Using national data, we examined if hospitals with high patient satisfaction have lower levels of performance on accepted measures of the quality and efficiency of surgical care. Federal policymakers have made patient satisfaction a core measure for the way hospitals are evaluated and paid through the value-based purchasing program. There is broad concern that performance on patient satisfaction may have little or even a negative correlation with the quality of surgical care, leading to potential trade-offs in efforts to improve patient experience with other surgical quality measures. We used the Hospital Consumer Assessment of Healthcare Providers and Systems survey data from 2010 and 2011 to assess performance on patient experience. We used national Medicare data on 6 common surgical procedures to calculate measures of surgical efficiency and quality: risk-adjusted length of stay, process score, risk-adjusted mortality rate, risk-adjusted readmission rate, and a composite z score across all 4 metrics. Multivariate models adjusting for hospital characteristics were used to assess the independent relationships between patient satisfaction and measures of surgical efficiency and quality. Of the 2953 US hospitals that perform one of these 6 procedures, the median patient satisfaction score was 69.5% (interquartile range, 63%-75.5%). Length of stay was shorter in hospitals with the highest levels of patient satisfaction (7.1 days vs 7.7 days, P patient satisfaction had the higher process of care performance (96.5 vs 95.5, P patient satisfaction also had a higher composite score for quality across all measures (P patient satisfaction provided more efficient care and were associated with higher surgical quality. Our findings suggest there need not be a trade-off between good quality of care for surgical patients and ensuring a positive patient experience.

  9. Pediatric medical device development by surgeons via capstone engineering design programs.

    Science.gov (United States)

    Sack, Bryan S; Elizondo, Rodolfo A; Huang, Gene O; Janzen, Nicolette; Espinoza, Jimmy; Sanz-Cortes, Magdalena; Dietrich, Jennifer E; Hakim, Julie; Richardson, Eric S; Oden, Maria; Hanks, John; Haridas, Balakrishna; Hury, James F; Koh, Chester J

    2018-03-01

    There is a need for pediatric medical devices that accommodate the unique physiology and anatomy of pediatric patients that is increasingly receiving more attention. However, there is limited literature on the programs within children's hospitals and academia that can support pediatric device development. We describe our experience with pediatric device design utilizing collaborations between a children's hospital and two engineering schools. Utilizing the academic year as a timeline, unmet pediatric device needs were identified by surgical faculty and matched with an engineering mentor and a team of students within the Capstone Engineering Design programs at two universities. The final prototypes were showcased at the end of the academic year and if appropriate, provisional patent applications were filed. All twelve teams successfully developed device prototypes, and five teams obtained provisional patents. The prototypes that obtained provisional patents included a non-operative ureteral stent removal system, an evacuation device for small kidney stone fragments, a mechanical leech, an anchoring system of the chorio-amniotic membranes during fetal surgery, and a fetal oxygenation monitor during fetoscopic procedures. Capstone Engineering Design programs in partnership with surgical faculty at children's hospitals can play an effective role in the prototype development of novel pediatric medical devices. N/A - No clinical subjects or human testing was performed. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Post-operative orbital imaging: a focus on implants and prosthetic devices

    International Nuclear Information System (INIS)

    Adams, Ashok; Mankad, Kshitij; Poitelea, Cornelia; Verity, David H.; Davagnanam, Indran

    2014-01-01

    Accurate interpretation of orbital imaging in the presence of either orbital implants requires a sound knowledge of both the surgical approach used and the imaging characteristics of the implanted devices themselves. In this article, the radiological appearance of the various devices used in ophthalmology, and their relationship to other orbital structures, is reviewed. In addition, the intended anatomical location, function of these devices, and clinical indications for their use are provided. (orig.)

  11. Instituting a Surgical Skills Competition Increases Technical Performance of Surgical Clerkship Students Over Time.

    Science.gov (United States)

    Leraas, Harold J; Cox, Morgan L; Bendersky, Victoria A; Sprinkle, Shanna S; Gilmore, Brian F; Gunasingha, Rathnayaka M; Tracy, Elisabeth T; Sudan, Ranjan

    2017-10-04

    Surgical skills training varies greatly between institutions and is often left to students to approach independently. Although many studies have examined single interventions of skills training, no data currently exists about the implementation of surgical skills assessment as a component of the medical student surgical curriculum. We created a technical skills competition and evaluated its effect on student surgical skill development. Second-year medical students enrolled in the surgery clerkship voluntarily participated in a surgical skills competition consisting of knot tying, laparoscopic peg transfer, and laparoscopic pattern cut. Winning students were awarded dinner with the chair of surgery and a resident of their choice. Individual event times and combined times were recorded and compared for students who completed without disqualification. Disqualification included compromising cutting pattern, dropping a peg out of the field of vision, and incorrect knot tying technique. Timed performance was compared for 2 subsequent academic years using Mann-Whitney U test. Overall, 175 students competed and 71 students met qualification criteria. When compared by academic year, 2015 to 2016 students (n = 34) performed better than 2014 to 2015 students (n = 37) in pattern cut (133s vs 167s, p = 0.040), peg transfer (66s vs 101s, p skills competition improves student technical performance. Further research is needed regarding long-term benefits of surgical competitions for medical students. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  12. The effect of video review of resident laparoscopic surgical skills measured by self- and external assessment.

    Science.gov (United States)

    Herrera-Almario, Gabriel E; Kirk, Katherine; Guerrero, Veronica T; Jeong, Kwonho; Kim, Sara; Hamad, Giselle G

    2016-02-01

    Video review of surgical skills is an educational modality that allows trainees to reflect on self-performance. The purpose of this study was to determine whether resident and attending assessments of a resident's laparoscopic performance differ and whether video review changes assessments. Third-year surgery residents were invited to participate. Elective laparoscopic procedures were video recorded. The Global Operative Assessment of Laparoscopic Skills evaluation was completed immediately after the procedure and again 7 to 10 days later by both resident and attending. Scores were compared using t tests. Nine residents participated and 76 video reviews were completed. Residents scored themselves significantly lower than the faculty scores both before and after video review. Resident scores did not change significantly after video review. Attending and resident self-assessment of laparoscopic skills differs and subsequent video review does not significantly affect Global Operative Assessment of Laparoscopic Skills scores. Further studies should evaluate the impact of video review combined with verbal feedback on skill acquisition and assessment. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Challenges in the Assessment of Medical Devices: The MedtecHTA Project.

    Science.gov (United States)

    Tarricone, Rosanna; Torbica, Aleksandra; Drummond, Michael

    2017-02-01

    Assessing medical devices (MDs) raises challenges which require us to reflect on whether current methods are adequate. Major features of devices are: (i) device-operator interaction can generate learning curve effects; (ii) incremental nature of innovation needs to be addressed by careful identification of the alternatives for comparative and incremental cost-effectiveness analysis; and (iii) broader organizational impact in terms of training and infrastructure, coupled with dynamic pricing, requires a more flexible approach to costing. The objective of the MedtecHTA project was to investigate improvements in HTA methods to allow for more comprehensive evaluation of MDs. It consisted of several work packages concerning (i) the available evidence on the currently adopted approaches for regulation and HTA of medical devices; (ii) the geographical variation in access to MDs; (iii) the development of methodological frameworks for conducting comparative effectiveness research and economic evaluation of MDs; and (iv) the organizational impact of MDs. This introductory paper summarizes the main results of the project and draws out the main overarching themes. This supplement represents a comprehensive report of all the main findings of the MedtecHTA project, and it is intended to be the main source for researchers and policy makers wanting information on the project. © 2017 The Authors. Health Economics published by John Wiley & Sons, Ltd. © 2017 The Authors. Health Economics Published by John Wiley & Sons, Ltd.

  14. The Basic Surgical Skills Course in Sub-Saharan Africa: An Observational Study of Effectiveness.

    Science.gov (United States)

    Fergusson, Stuart J; Sedgwick, David M; Ntakiyiruta, Georges; Ntirenganya, Faustin

    2018-04-01

    The Basic Surgical Skills (BSS) course is a common component of postgraduate surgical training programmes in sub-Saharan Africa, but was originally designed in a UK context, and its efficacy and relevance have not been formally assessed in Africa. An observational study was carried out during a BSS course delivered to early-stage surgical trainees from Rwanda and the Democratic Republic of the Congo. Technical skill in a basic wound closure task was assessed in a formal Objective Structured Assessment of Technical Skills (OSAT) before and after course completion. Participants completed a pre-course questionnaire documenting existing surgical experience and self-perceived confidence levels in surgical skills which were to be taught during the course. Participants repeated confidence ratings and completed course evaluation following course delivery. A cohort of 17 participants had completed a pre-course median of 150 Caesarean sections as primary operator. Performance on the OSAT improved from a mean of 10.5/17 pre-course to 14.2/17 post-course (mean of paired differences 3.7, p skills taught, and the course was assessed as highly relevant by trainees. The Basic Surgical Skills course is effective in improving the basic surgical technique of surgical trainees from sub-Saharan Africa and their confidence in key technical skills.

  15. Pre-surgical planning and MR-tractography utility in brain tumour resection

    Energy Technology Data Exchange (ETDEWEB)

    Romano, A.; Fantozzi, L.M.; Bozzao, A. [University Sapienza, Department of Neuroradiology, S. Andrea Hospital, Rome (Italy); D' Andrea, G.; Mastronardi, L.; Ferrante, L. [University Sapienza, Department of Neurosurgery, S. Andrea Hospital, Rome (Italy); Minniti, G. [University Sapienza, Department of Radiotherapy, S. Andrea Hospital, Rome (Italy)

    2009-12-15

    The purposes of this study were (1) to evaluate the possible identification of trajectories of fibre tracts, (2) to examine the useful of a neuronavigation system for pre-surgical planning, (3) to assess pre- and post-surgery patients' clinical condition and (4) to evaluate the impact of this information on surgical planning and procedure. Twenty-eight right-handed patients were prospectively and consecutively studied. All the patients were clinically assessed by a neurologist in both pre- and post-surgical phases. Separately the pyramidal tract, optic radiation and arcuate fasciculus were reconstructed. The trajectories were considered suitable for surgical planning if there were no interruptions of any of the layers at the level of the lesion. Dedicated software 'merged' the acquired images with the tractographic processing, and the whole dataset was sent to the neuronavigation system. The assessment of the 37 visualised trajectories close to the tumour resulted in a modification of the surgical approach to corticotomy in six patients (21%); the impact on the definition of the resection margins during surgery was 64% (18 cases). The overall impact percentage on the surgical procedure was 82%. In 27 cases, the symptoms had not changed. MR-tractography provides the neurosurgeon with a new anatomical view that has an impact on the surgical resection planning for brain neoplasms. (orig.)

  16. Pre-surgical planning and MR-tractography utility in brain tumour resection

    International Nuclear Information System (INIS)

    Romano, A.; Fantozzi, L.M.; Bozzao, A.; D'Andrea, G.; Mastronardi, L.; Ferrante, L.; Minniti, G.

    2009-01-01

    The purposes of this study were (1) to evaluate the possible identification of trajectories of fibre tracts, (2) to examine the useful of a neuronavigation system for pre-surgical planning, (3) to assess pre- and post-surgery patients' clinical condition and (4) to evaluate the impact of this information on surgical planning and procedure. Twenty-eight right-handed patients were prospectively and consecutively studied. All the patients were clinically assessed by a neurologist in both pre- and post-surgical phases. Separately the pyramidal tract, optic radiation and arcuate fasciculus were reconstructed. The trajectories were considered suitable for surgical planning if there were no interruptions of any of the layers at the level of the lesion. Dedicated software 'merged' the acquired images with the tractographic processing, and the whole dataset was sent to the neuronavigation system. The assessment of the 37 visualised trajectories close to the tumour resulted in a modification of the surgical approach to corticotomy in six patients (21%); the impact on the definition of the resection margins during surgery was 64% (18 cases). The overall impact percentage on the surgical procedure was 82%. In 27 cases, the symptoms had not changed. MR-tractography provides the neurosurgeon with a new anatomical view that has an impact on the surgical resection planning for brain neoplasms. (orig.)

  17. Diagnostic Efficiency in Digital Pathology: A Comparison of Optical Versus Digital Assessment in 510 Surgical Pathology Cases.

    Science.gov (United States)

    Mills, Anne M; Gradecki, Sarah E; Horton, Bethany J; Blackwell, Rebecca; Moskaluk, Christopher A; Mandell, James W; Mills, Stacey E; Cathro, Helen P

    2018-01-01

    Prior work has shown that digital images and microscopic slides can be interpreted with comparable diagnostic accuracy. Although accuracy has been well-validated, the interpretative time for digital images has scarcely been studied and concerns about efficiency remain a major barrier to adoption. We investigated the efficiency of digital pathology when compared with glass slide interpretation in the diagnosis of surgical pathology biopsy and resection specimens. Slides were pulled from 510 surgical pathology cases from 5 organ systems (gastrointestinal, gynecologic, liver, bladder, and brain). Original diagnoses were independently confirmed by 2 validating pathologists. Diagnostic slides were scanned using the Philips IntelliSite Pathology Solution. Each case was assessed independently on digital and optical by 3 reading pathologists, with a ≥6 week washout period between modalities. Reading pathologists recorded assessment times for each modality; digital times included time to load the case. Diagnostic accuracy was determined based on whether a rendered diagnosis differed significantly from the original diagnosis. Statistical analysis was performed to assess for differences in interpretative times across modalities. All 3 reading pathologists showed comparable diagnostic accuracy across optical and digital modalities (mean major discordance rates with original diagnosis: 4.8% vs. 4.4%, respectively). Mean assessment times ranged from 1.2 to 9.1 seconds slower on digital versus optical. The slowest reader showed a significant learning effect during the course of the study so that digital assessment times decreased over time and were comparable with optical times by the end of the series. Organ site and specimen type did not significantly influence differences in interpretative times. In summary, digital image reading times compare favorably relative to glass slides across a variety of organ systems and specimen types. Mean increase in assessment time is 4

  18. Assessment of skills using a virtual reality temporal bone surgery simulator.

    Science.gov (United States)

    Linke, R; Leichtle, A; Sheikh, F; Schmidt, C; Frenzel, H; Graefe, H; Wollenberg, B; Meyer, J E

    2013-08-01

    Surgery on the temporal bone is technically challenging due to its complex anatomy. Precise anatomical dissection of the human temporal bone is essential and is fundamental for middle ear surgery. We assessed the possible application of a virtual reality temporal bone surgery simulator to the education of ear surgeons. Seventeen ENT physicians with different levels of surgical training and 20 medical students performed an antrotomy with a computer-based virtual temporal bone surgery simulator. The ease, accuracy and timing of the simulated temporal bone surgery were assessed using the automatic assessment software provided by the simulator device and additionally with a modified Final Product Analysis Scale. Trained ENT surgeons, physicians without temporal bone surgical training and medical students were all able to perform the antrotomy. However, the highly trained ENT surgeons were able to complete the surgery in approximately half the time, with better handling and accuracy as assessed by the significant reduction in injury to important middle ear structures. Trained ENT surgeons achieved significantly higher scores using both dissection analysis methods. Surprisingly, there were no significant differences in the results between medical students and physicians without experience in ear surgery. The virtual temporal bone training system can stratify users of known levels of experience. This system can be used not only to improve the surgical skills of trained ENT surgeons for more successful and injury-free surgeries, but also to train inexperienced physicians/medical students in developing their surgical skills for the ear.

  19. Characterization of aerosols produced by surgical procedures

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, H.C.; Muggenburg, B.A.; Lundgren, D.L.; Guilmette, R.A.; Snipes, M.B.; Jones, R.K. [Inhalation Toxicology Research Institute, Albuquerque, NM (United States); Turner, R.S. [Lovelace Health Systems, Albuquerque, NM (United States)

    1994-07-01

    In many surgeries, especially orthopedic procedures, power tools such as saws and drills are used. These tools may produce aerosolized blood and other biological material from bone and soft tissues. Surgical lasers and electrocautery tools can also produce aerosols when tissues are vaporized and condensed. Studies have been reported in the literature concerning production of aerosols during surgery, and some of these aerosols may contain infectious material. Garden et al. (1988) reported the presence of papilloma virus DNA in the fumes produced from laser surgery, but the infectivity of the aerosol was not assessed. Moon and Nininger (1989) measured the size distribution and production rate of emissions from laser surgery and found that particles were generally less than 0.5 {mu}m diameter. More recently there has been concern expressed over the production of aerosolized blood during surgical procedures that require power tools. In an in vitro study, the production of an aerosol containing the human immunodeficiency virus (HIV) was reported when power tools were used to cut tissues with blood infected with HIV. Another study measured the size distribution of blood aerosols produced by surgical power tools and found blood-containing particles in a number of size ranges. Health care workers are anxious and concerned about whether surgically produced aerosols are inspirable and can contain viable pathogens such as HIV. Other pathogens such as hepatitis B virus (HBV) are also of concern. The Occupational Safety and Health funded a project at the National Institute for Inhalation Toxicology Research Institute to assess the extent of aerosolization of blood and other tissues during surgical procedures. This document reports details of the experimental and sampling approach, methods, analyses, and results on potential production of blood-associated aerosols from surgical procedures in the laboratory and in the hospital surgical suite.

  20. Long-term surgical-orthodontic management of hemimandibular hyperplasia.

    Science.gov (United States)

    Bennett, Samuel C; Goonewardene, Mithran S

    2016-05-01

    Hemimandibular hyperplasia (HH), also known as hemimandibular hypertrophy, is characterised by excessive unilateral three-dimensional growth of the mandible after birth. Vertical unilateral elongation of the mandible becomes clinically evident as a rare form of vertical facial asymmetry. Aberrant growth of the facial skeleton affects the developing dentition and the dental compensatory mechanism is usually unable to maintain optimal occlusal relationships. The resulting malocclusion is effectively managed by combined surgical-orthodontic care to address the facial, skeletal and dental problems that confront clinicians. Orthodontists are advised to assess patients with HH during the post-treatment retention stage for continuing mandibular growth and assess the stability of treatment outcomes with long-term follow-up and records as required. To present a case of hemimandibular hyperplasia treated successfully by combined surgical-orthodontic care and evaluated for stability over a seven-year follow-up period. Surgical-orthodontic management was accomplished in four stages: 1) pre-surgical orthodontic; 21 surgical; 3) post-surgical orthodontic; and 4) post-treatment orthodontic retention. Complete orthodontic records, including extra- and intra-oral photographs, study models, and cephalograms plus panoramic radiographs were taken at the pretreatment, post-treatment, and seven-year orthodontic retention time-points. Facial, skeletal and dental goals were achieved in the three planes of space and the long-term stability of the treatment results was shown during a post-treatment orthodontic retention period of seven years. Hemimandibular hyperplasia is a true growth anomaly which may be managed effectively. Clinicians may expect successful long-term correction and stability by utilising a comprehensive surgical-orthodontic treatment approach.

  1. Mental training in surgical education: a systematic review.

    Science.gov (United States)

    Davison, Sara; Raison, Nicholas; Khan, Muhammad S; Dasgupta, Prokar; Ahmed, Kamran

    2017-11-01

    Pressures on surgical education from restricted working hours and increasing scrutiny of outcomes have been compounded by the development of highly technical surgical procedures requiring additional specialist training. Mental training (MT), the act of performing motor tasks in the 'mind's eye', offers the potential for training outside the operating room. However, the technique is yet to be formally incorporated in surgical curricula. This study aims to review the available literature to determine the role of MT in surgical education. EMBASE and Medline databases were searched. The primary outcome measure was surgical proficiency following training. Secondary analyses examined training duration, forms of MT and trainees level of experience. Study quality was assessed using Consolidated Standards of Reporting Trials scores or Quality Assessment Tool for Before-After (Pre-Post) Studies with No Control Group. Fourteen trials with 618 participants met the inclusion criteria, of which 11 were randomized and three longitudinal. Ten studies found MT to be beneficial. Mental rehearsal was the most commonly used form of training. No significant correlation was found between the length of MT and outcomes. MT benefitted expert surgeons more than medical students or novice surgeons. The majority studies demonstrate MT to be beneficial in surgical education especially amongst more experienced surgeons within a well-structured MT programme. However, overall studies were low quality, lacked sufficient methodology and suffered from small sample sizes. For these reasons, further research is required to determine optimal role of MT as a supplementary educational tool within the surgical curriculum. © 2017 Royal Australasian College of Surgeons.

  2. Abortion - surgical

    Science.gov (United States)

    Suction curettage; Surgical abortion; Elective abortion - surgical; Therapeutic abortion - surgical ... Surgical abortion involves dilating the opening to the uterus (cervix) and placing a small suction tube into the uterus. ...

  3. Fiber Bragg grating based arterial localization device

    Science.gov (United States)

    Ho, Siu Chun Michael; Li, Weijie; Razavi, Mehdi; Song, Gangbing

    2017-06-01

    A critical first step to many surgical procedures is locating and gaining access to a patients vascular system. Vascular access allows the deployment of other surgical instruments and also the monitoring of many physiological parameters. Current methods to locate blood vessels are predominantly based on the landmark technique coupled with ultrasound, fluoroscopy, or Doppler. However, even with experience and technological assistance, locating the required blood vessel is not always an easy task, especially with patients that present atypical anatomy or suffer from conditions such as weak pulsation or obesity that make vascular localization difficult. With recent advances in fiber optic sensors, there is an opportunity to develop a new tool that can make vascular localization safer and easier. In this work, the authors present a new fiber Bragg grating (FBG) based vascular access device that specializes in arterial localization. The device estimates the location towards a local artery based on the bending of a needle inserted near the tissue surrounding the artery. Experimental results obtained from an artificial circulatory loop and a mock artery show the device works best for lower angles of needle insertion and can provide an approximately 40° range of estimation towards the location of a pulsating source (e.g. an artery).

  4. Surgical Education's 100 Most Cited Articles: A Bibliometric Analysis.

    Science.gov (United States)

    Matthews, Alexander H; Abdelrahman, Tarig; Powell, Arfon G M T; Lewis, Wyn G

    2016-01-01

    Bibliometric analysis highlights the key topics and publications, which have shaped surgical education. Here, the 100 most cited articles in the arena of surgical education were analyzed. Thomson Reuters Web of Science was interrogated using the keyword search terms "surgery" and ("learning" or "skills" or "competence" or "assessment" or "training" or "procedure-based assessments" or "performance" or "technical skills" or "curriculum" or "education" or "mentoring"] to identify all English language full articles, and the 100 most cited articles were analyzed by topic, journal, author, year, institution, and country of origin. A total of 403,733 eligible articles were returned and the median citation number was 164 (range: 107-1018). The most cited article (by Seymour, Yale University School of Medicine, Annals of Surgery, 1018 citations) focused on the use of virtual reality surgical simulation training. Annals of Surgery published the highest number of articles and received the most citations (n = 16, 3715 citations). The countries with the greatest number of publications were the USA (n = 45), Canada (n = 19), and the UK (n = 18). The commonest topics included simulation (n = 45) and assessment of clinical competence (n = 40). Surgical skill acquisition and assessment was the area of focus of 85% of the most cited contemporary articles, and this study provides the most cited references, serving as a guide as to what makes a citable published work in the field of surgical education. Copyright © 2016 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  5. Non-observance of guidelines for surgical antimicrobial prophylaxis and surgical-site infections.

    Science.gov (United States)

    Lallemand, S; Thouverez, M; Bailly, P; Bertrand, X; Talon, D

    2002-06-01

    A prospective multicentre study was conducted to assess major aspects of surgical prophylaxis and to determine whether inappropriate antimicrobial prophylaxis was a factor associated (risk or protective factor) with surgical site infection (SSI). Surgical prophylaxis practices were assessed by analysing four variables: indication, antimicrobial agent, timing and duration. Univariate and multivariate analyses were carried out to identify predictors of SSI among patient-specific, operation-specific and antimicrobial prophylaxis-specific factors. The frequency of SSI was 2.7% (13 SSI in 474 observations). Total compliance of the prescription with guidelines was observed in 41.1% of cases (195 prescriptions). Of the 139 patients who received an inappropriate drug, 126 (90.6%) received a drug with a broader spectrum than the recommended drug. Prophylaxis was prolonged in 71 (87.7%) of the 81 patients who received prophylaxis for inappropriate lengths of time and 43 (61.4%) of the 70 patients who did not receive prophylaxis at the optimal moment were treated too late. Multivariate analysis clearly demonstrated that SSI was associated with multiple procedures (relative risk 8.5), short duration of prophylaxis (relative risk 12.7) and long-term therapy with antimicrobial agents during the previous year (relative risk 8.8). The ecological risk of the emergence of resistance associated with the frequent use of broad-spectrum antibiotics and prophylaxis for longer periods was not offset by individual benefit to the patients who received inappropriate prophylaxis.

  6. A socio-technical, probabilistic risk assessment model for surgical site infections in ambulatory surgery centers.

    Science.gov (United States)

    Bish, Ebru K; El-Amine, Hadi; Steighner, Laura A; Slonim, Anthony D

    2014-10-01

    To understand how structural and process elements may affect the risk for surgical site infections (SSIs) in the ambulatory surgery center (ASC) environment, the researchers employed a tool known as socio-technical probabilistic risk assessment (ST-PRA). ST-PRA is particularly helpful for estimating risks in outcomes that are very rare, such as the risk of SSI in ASCs. Study objectives were to (1) identify the risk factors associated with SSIs resulting from procedures performed at ASCs and (2) design an intervention to mitigate the likelihood of SSIs for the most common risk factors that were identified by the ST-PRA for a particular surgical procedure. ST-PRA was used to study the SSI risk in the ASC setting. Both quantitative and qualitative data sources were utilized, and sensitivity analysis was performed to ensure the robustness of the results. The event entitled "fail to protect the patient effectively" accounted for 51.9% of SSIs in the ambulatory care setting. Critical components of this event included several failure risk points related to skin preparation, antibiotic administration, staff training, proper response to glove punctures during surgery, and adherence to surgical preparation rules related to the wearing of jewelry, watches, and artificial nails. Assuming a 75% reduction in noncompliance on any combination of 2 of these 5 components, the risk for an SSI decreased from 0.0044 to between 0.0027 and 0.0035. An intervention that targeted the 5 major components of the major risk point was proposed, and its implications were discussed.

  7. OR.NET: a service-oriented architecture for safe and dynamic medical device interoperability.

    Science.gov (United States)

    Kasparick, Martin; Schmitz, Malte; Andersen, Björn; Rockstroh, Max; Franke, Stefan; Schlichting, Stefan; Golatowski, Frank; Timmermann, Dirk

    2018-02-23

    Modern surgical departments are characterized by a high degree of automation supporting complex procedures. It recently became apparent that integrated operating rooms can improve the quality of care, simplify clinical workflows, and mitigate equipment-related incidents and human errors. Particularly using computer assistance based on data from integrated surgical devices is a promising opportunity. However, the lack of manufacturer-independent interoperability often prevents the deployment of collaborative assistive systems. The German flagship project OR.NET has therefore developed, implemented, validated, and standardized concepts for open medical device interoperability. This paper describes the universal OR.NET interoperability concept enabling a safe and dynamic manufacturer-independent interconnection of point-of-care (PoC) medical devices in the operating room and the whole clinic. It is based on a protocol specifically addressing the requirements of device-to-device communication, yet also provides solutions for connecting the clinical information technology (IT) infrastructure. We present the concept of a service-oriented medical device architecture (SOMDA) as well as an introduction to the technical specification implementing the SOMDA paradigm, currently being standardized within the IEEE 11073 service-oriented device connectivity (SDC) series. In addition, the Session concept is introduced as a key enabler for safe device interconnection in highly dynamic ensembles of networked medical devices; and finally, some security aspects of a SOMDA are discussed.

  8. Post surgical complications from students' large animal surgical ...

    African Journals Online (AJOL)

    A retrospective study of post surgical complications was conducted on records of students' Large Animal Surgical Laboratories in the Faculty of Veterinary Medicine (F.V.M.), Ahmadu Bello University (A.B.U), Zaria from 1989 to 1993. Three hundred and eleven surgical complications were recorded from five surgical ...

  9. Ahmed glaucoma valve implant: surgical technique and complications.

    Science.gov (United States)

    Riva, Ivano; Roberti, Gloria; Oddone, Francesco; Konstas, Anastasios Gp; Quaranta, Luciano

    2017-01-01

    Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications.

  10. Patient satisfaction: does surgical volume matter?

    Science.gov (United States)

    Tevis, Sarah E; Kennedy, Gregory D

    2015-06-01

    Patient satisfaction is an increasing area of interest due to implications of pay for performance and public reporting of results. Although scores are adjusted for patient factors, little is known about the relationship between hospital structure, postoperative outcomes, and patient satisfaction with the hospital experience. Hospitals participating in the University HealthSystem Consortium database from 2011-2012 were included. Patients were restricted to those discharged by general surgeons to isolate surgical patients. Hospital data were paired with Hospital Consumer Assessment of Healthcare Providers and Systems (HCAHPS) results from the Hospital Compare website. Postoperative outcomes were dichotomized based on the median for all hospitals and stratified based on surgical volume. The primary outcome of interest was high on overall patient satisfaction, whereas other HCAHPS domains were assessed as secondary outcomes. Chi square and binary logistic regression analyses were performed to evaluate whether postoperative outcomes or surgical volume more significantly influenced high patient satisfaction. The study population consisted of 171 hospitals from the University HealthSystem Consortium database. High surgical volume was a more important predictor of overall patient satisfaction regardless of hospital complication (P patient satisfaction on the HCAHPS survey than postoperative outcomes, whereas volume was less predictive in other HCAHPS domains. Patients may require more specific questioning to identify high quality, safe hospitals. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Ethics, economics and the regulation and adoption of new medical devices: case studies in pelvic floor surgery

    Science.gov (United States)

    2010-01-01

    Background Concern has been growing in the academic literature and popular media about the licensing, introduction and adoption of surgical devices before full effectiveness and safety evidence is available to inform clinical practice. Our research will seek empirical survey evidence about the roles, responsibilities, and information and policy needs of the key stakeholders in the introduction into clinical practice of new surgical devices for pelvic floor surgery, in terms of the underlying ethical principals involved in the economic decision-making process, using the example of pelvic floor procedures. Methods/Design Our study involves three linked case studies using, as examples, selected pelvic floor surgery devices representing Health Canada device safety risk classes: low, medium and high risk. Data collection will focus on stakeholder roles and responsibilities, information and policy needs, and perceptions of those of other key stakeholders, in seeking and using evidence about new surgical devices when licensing and adopting them into practice. For each class of device, interviews will be used to seek the opinions of stakeholders. The following stakeholders and ethical and economic principles provide the theoretical framework for the study: Stakeholders - federal regulatory body, device manufacturers, clinicians, patients, health care institutions, provincial health departments, and professional societies. Clinical settings in two centres (in different provinces) will be included. Ethics - beneficence, non-maleficence, autonomy, justice. Economics - scarcity of resources, choices, opportunity costs. For each class of device, responses will be analysed to compare and contrast between stakeholders. Applied ethics and economic theory, analysis and critical interpretation will be used to further illuminate the case study material. Discussion The significance of our research in this new area of ethics will lie in providing recommendations for regulatory bodies

  12. Ethics, economics and the regulation and adoption of new medical devices: case studies in pelvic floor surgery

    Directory of Open Access Journals (Sweden)

    Ross Sue

    2010-08-01

    Full Text Available Abstract Background Concern has been growing in the academic literature and popular media about the licensing, introduction and adoption of surgical devices before full effectiveness and safety evidence is available to inform clinical practice. Our research will seek empirical survey evidence about the roles, responsibilities, and information and policy needs of the key stakeholders in the introduction into clinical practice of new surgical devices for pelvic floor surgery, in terms of the underlying ethical principals involved in the economic decision-making process, using the example of pelvic floor procedures. Methods/Design Our study involves three linked case studies using, as examples, selected pelvic floor surgery devices representing Health Canada device safety risk classes: low, medium and high risk. Data collection will focus on stakeholder roles and responsibilities, information and policy needs, and perceptions of those of other key stakeholders, in seeking and using evidence about new surgical devices when licensing and adopting them into practice. For each class of device, interviews will be used to seek the opinions of stakeholders. The following stakeholders and ethical and economic principles provide the theoretical framework for the study: Stakeholders - federal regulatory body, device manufacturers, clinicians, patients, health care institutions, provincial health departments, and professional societies. Clinical settings in two centres (in different provinces will be included. Ethics - beneficence, non-maleficence, autonomy, justice. Economics - scarcity of resources, choices, opportunity costs. For each class of device, responses will be analysed to compare and contrast between stakeholders. Applied ethics and economic theory, analysis and critical interpretation will be used to further illuminate the case study material. Discussion The significance of our research in this new area of ethics will lie in providing

  13. Do single-use medical devices containing biopolymers reduce the environmental impacts of surgical procedures compared with their plastic equivalents?

    Science.gov (United States)

    Unger, Scott R; Hottle, Troy A; Hobbs, Shakira R; Thiel, Cassandra L; Campion, Nicole; Bilec, Melissa M; Landis, Amy E

    2017-01-01

    Background While petroleum-based plastics are extensively used in health care, recent developments in biopolymer manufacturing have created new opportunities for increased integration of biopolymers into medical products, devices and services. This study compared the environmental impacts of single-use disposable devices with increased biopolymer content versus typically manufactured devices in hysterectomy. Methods A comparative life cycle assessment of single-use disposable medical products containing plastic(s) versus the same single-use medical devices with biopolymers substituted for plastic(s) at Magee-Women's Hospital (Magee) in Pittsburgh, PA and the products used in four types of hysterectomies that contained plastics potentially suitable for biopolymer substitution. Magee is a 360-bed teaching hospital, which performs approximately 1400 hysterectomies annually. Results There are life cycle environmental impact tradeoffs when substituting biopolymers for petroplastics in procedures such as hysterectomies. The substitution of biopolymers for petroleum-based plastics increased smog-related impacts by approximately 900% for laparoscopic and robotic hysterectomies, and increased ozone depletion-related impacts by approximately 125% for laparoscopic and robotic hysterectomies. Conversely, biopolymers reduced life cycle human health impacts, acidification and cumulative energy demand for the four hysterectomy procedures. The integration of biopolymers into medical products is correlated with reductions in carcinogenic impacts, non-carcinogenic impacts and respiratory effects. However, the significant agricultural inputs associated with manufacturing biopolymers exacerbate environmental impacts of products and devices made using biopolymers. Conclusions The integration of biopolymers into medical products is correlated with reductions in carcinogenic impacts, non-carcinogenic impacts and respiratory effects; however, the significant agricultural inputs associated

  14. Obesity and Surgical Treatment – A Cost-Effectiveness Assessment for Sweden

    Directory of Open Access Journals (Sweden)

    Sixten Borg

    2014-07-01

    Full Text Available Background:The rising trend in the prevalence of obesity has during the past decades become a major public health concern in many countries, as obesity may lead to comorbidities and death. A frequent used marker for obesity is the Body Mass Index (BMI. The cost of treatment for obesity related diseases has become a heavy burden on national health care budget in many countries. While diet and exercise are the cornerstones of weight management, pharmaco­therapy is often needed to achieve and maintain desired weight loss.  In some cases of extreme obesity, bariatric surgery may be recommended. It is expected to increase by 50% in Sweden.Objective: The overall objective was to develop a cost-effectiveness model using the best available evidence to assess the cost-effectiveness of gastric bypass (GBP surgical treatments for obesity in adult patients, in comparison with conventional treatment (CT, in Sweden from a healthcare perspective. With the model we also seeked to identify the lower cut-off point using BMI criteria, for the surgical intervention to be cost-effective. Methods:A micro-simulation model with an underlying Markov methodology was developed, that simulates individual patients. It simulates the outcomes of the patients in terms of treatment costs, life years, and quality adjusted life years (QALY over his/her remaining lifetime. The costs are presented in SEK in the year 2006 price level (1 SEK ≈ 0.11 EUR ≈ 0.14 USD.Results: We estimated that the incremental cost per QALY gained will not exceed SEK 33,000 per QALY in patients with BMI < 35. In patients with BMI > 35 kg/m2, gastric bypass surgery has lower costs compared to conventional treatment. Conclusion: Gastric bypass surgery is a cost-effective intervention compared to conventional treatment consisting of watchful waiting, diet and exercise.

  15. Is there still a role for experimental surgery in the surgical sciences?

    Science.gov (United States)

    Di Cataldo, Antonio

    2006-01-01

    The firm opposition of public opinion and the reduction in public funding have remarkably curtailed the role of experimental surgery which several years ago was a key aspect of the activity of a surgical department. Experimental surgery in large animals has been virtually banned and experimental research in small animals requires the use of complex microsurgical techniques. In our opinion, experimental surgery is still useful in order to test new surgical devices and new drugs, especially in the field of transplant surgery. Another important function of experimental surgery is to facilitate the training of surgical residents in order to speed up the process of acquiring experience and expertise. Public opinion can be reassured because the legislation is very strict and safeguards the well-being of animals.

  16. Surgical assessment clinic - One stop emergency out-patient clinic for rapid assessment, reduced admissions and improved acute surgical service: A quality improvement study

    Directory of Open Access Journals (Sweden)

    Christina A.W. Macano

    2017-11-01

    Conclusion: By providing suitable guidance for referring practitioners we have optimised our clinic use significantly and improved our acute ambulatory surgical care. We have reduced admissions, provided rapid treatment and have established a service that helps address the ever increasing demand on acute services within the NHS.

  17. The role of cardiovascular magnetic resonance in assessment of patients after radical surgical correction of tetralogy of Fallot

    International Nuclear Information System (INIS)

    Genova, K.; Dasheva, A.

    2014-01-01

    Surgical management of tetralogy of Fallot (TOF) results in residual anatomic and functional abnormalities in majority of patients. Primarily considered as a benign pulmonary regurgitation with the time results in right ventricular overload, loses the compensatory mechanisms and irreversible right ventricular dilatation and dysfunction. Cardiovascular magnetic resonance (CMR) has evolved during the last two decades as the reference standard imaging modality to assess the anatomic and functional changes in patients with repaired TOF. This article reviews the role of CMR to assess the right ventricular function and to evaluate the degree of pulmonary regurgitation and comments some technical aspects, based to our experience. Key words: Tetralogy of Fallot. Cardiovascular Magnetic Resonance. Pulmonary regurgitation. Right ventricular assessment

  18. Comprehensive Surgical Coaching Enhances Surgical Skill in the Operating Room: A Randomized Controlled Trial.

    Science.gov (United States)

    Bonrath, Esther M; Dedy, Nicolas J; Gordon, Lauren E; Grantcharov, Teodor P

    2015-08-01

    The aim of the study was to determine whether individualized coaching improved surgical technical skill in the operating room to a higher degree than current residency training. Clinical training in the operating room is a valuable opportunity for surgeons to acquire skill and knowledge; however, it often remains underutilized. Coaching has been successfully used in various industries to enhance performance, but its role in surgery has been insufficiently investigated. This randomized controlled trial was conducted at one surgical training program. Trainees undergoing a minimally invasive surgery rotation were randomized to either conventional training (CT) or comprehensive surgical coaching (CSC). CT included ward and operating room duties, and regular departmental teaching sessions. CSC comprised performance analysis, debriefing, feedback, and behavior modeling. Primary outcome measures were technical performance as measured on global and procedure-specific rating scales, and surgical safety parameters, measured by error count. Operative performance was assessed by blinded video analysis of the first and last cases recorded by the participants during their rotation. Twenty residents were randomized and 18 completed the study. At posttraining the CSC group (n = 9) scored significantly higher on a procedure-specific skill scale compared with the CT group (n = 9) [median, 3.90 (interquartile range, 3.68-4.30) vs 3.60 (2.98-3.70), P = 0.017], and made fewer technical errors [10 (7-13) vs 18 (13-21), P = 0.003]. Significant within-group improvements for all skill metrics were only noted in the CSC group. Comprehensive surgical coaching enhances surgical training and results in skill acquisition superior to conventional training.

  19. Orthognathic positioning system: intraoperative system to transfer virtual surgical plan to operating field during orthognathic surgery.

    Science.gov (United States)

    Polley, John W; Figueroa, Alvaro A

    2013-05-01

    To introduce the concept and use of an occlusal-based "orthognathic positioning system" (OPS) to be used during orthognathic surgery. The OPS consists of intraoperative occlusal-based devices that transfer virtual surgical planning to the operating field for repositioning of the osteotomized dentoskeletal segments. The system uses detachable guides connected to an occlusal splint. An initial drilling guide is used to establish stable references or landmarks. These are drilled on the bone that will not be repositioned adjacent to the osteotomy line. After mobilization of the skeletal segment, a final positioning guide, referenced to the drilled landmarks, is used to transfer the skeletal segment according to the virtual surgical planning. The OPS is digitally designed using 3-dimensional computer-aided design/computer-aided manufacturing technology and manufactured with stereolithographic techniques. Virtual surgical planning has improved the preoperative assessment and, in conjunction with the OPS, the execution of orthognathic surgery. The OPS has the possibility to eliminate the inaccuracies commonly associated with traditional orthognathic surgery planning and to simplify the execution by eliminating surgical steps such as intraoperative measuring, determining the condylar position, the use of bulky intermediate splints, and the use of intermaxillary wire fixation. The OPS attempts precise translation of the virtual plan to the operating field, bridging the gap between virtual and actual surgery. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Using the virtual reality device Oculus Rift for neuropsychological assessment of visual processing capabilities.

    Science.gov (United States)

    Foerster, Rebecca M; Poth, Christian H; Behler, Christian; Botsch, Mario; Schneider, Werner X

    2016-11-21

    Neuropsychological assessment of human visual processing capabilities strongly depends on visual testing conditions including room lighting, stimuli, and viewing-distance. This limits standardization, threatens reliability, and prevents the assessment of core visual functions such as visual processing speed. Increasingly available virtual reality devices allow to address these problems. One such device is the portable, light-weight, and easy-to-use Oculus Rift. It is head-mounted and covers the entire visual field, thereby shielding and standardizing the visual stimulation. A fundamental prerequisite to use Oculus Rift for neuropsychological assessment is sufficient test-retest reliability. Here, we compare the test-retest reliabilities of Bundesen's visual processing components (visual processing speed, threshold of conscious perception, capacity of visual working memory) as measured with Oculus Rift and a standard CRT computer screen. Our results show that Oculus Rift allows to measure the processing components as reliably as the standard CRT. This means that Oculus Rift is applicable for standardized and reliable assessment and diagnosis of elementary cognitive functions in laboratory and clinical settings. Oculus Rift thus provides the opportunity to compare visual processing components between individuals and institutions and to establish statistical norm distributions.

  1. Progress in virtual reality simulators for surgical training and certification.

    Science.gov (United States)

    de Visser, Hans; Watson, Marcus O; Salvado, Olivier; Passenger, Joshua D

    2011-02-21

    There is increasing evidence that educating trainee surgeons by simulation is preferable to traditional operating-room training methods with actual patients. Apart from reducing costs and risks to patients, training by simulation can provide some unique benefits, such as greater control over the training procedure and more easily defined metrics for assessing proficiency. Virtual reality (VR) simulators are now playing an increasing role in surgical training. However, currently available VR simulators lack the fidelity to teach trainees past the novice-to-intermediate skills level. Recent technological developments in other industries using simulation, such as the games and entertainment and aviation industries, suggest that the next generation of VR simulators should be suitable for training, maintenance and certification of advanced surgical skills. To be effective as an advanced surgical training and assessment tool, VR simulation needs to provide adequate and relevant levels of physical realism, case complexity and performance assessment. Proper validation of VR simulators and an increased appreciation of their value by the medical profession are crucial for them to be accepted into surgical training curricula.

  2. Nursing assessment of continuous vital sign surveillance to improve patient safety on the medical/surgical unit.

    Science.gov (United States)

    Watkins, Terri; Whisman, Lynn; Booker, Pamela

    2016-01-01

    Evaluate continuous vital sign surveillance as a tool to improve patient safety in the medical/surgical unit. Failure-to-rescue is an important measure of hospital quality. Patient deterioration is often preceded by changes in vital signs. However, continuous multi-parameter vital sign monitoring may decrease patient safety with an abundance of unnecessary alarms. Prospective observational study at two geographically disperse hospitals in a single hospital system. A multi-parameter vital sign monitoring system was installed in a medical/surgical unit in Utah and one in Alabama providing continuous display of SpO2, heart rate, blood pressure and respiration rate on a central station. Alarm thresholds and time to alert annunciations were set based on prior analysis of the distribution of each vital sign. At the end of 4 weeks, nurses completed a survey on their experience. An average alert per patient, per day was determined retrospectively from the saved vital signs data and knowledge of the alarm settings. Ninety-two per cent of the nurses agreed that the number of alarms and alerts were appropriate; 54% strongly agreed. On average, both units experienced 10·8 alarms per patient, per day. One hundred per cent agreed the monitor provided valuable patient data that increased patient safety; 79% strongly agreed. Continuous, multi-parameter patient monitoring could be performed on medical/surgical units with a small and appropriate level of alarms. Continuous vital sign assessment may have initiated nursing interventions that prevented failure-to-rescue events. Nurses surveyed unanimously agreed that continuous vital sign surveillance will help enhance patient safety. Nursing response to abnormal vital signs is one of the most important levers in patient safety, by providing timely recognition of early clinical deterioration. This occurs through diligent nursing surveillance, involving assessment, interpretation of data, recognition of a problem and meaningful

  3. Is surgical workforce diversity increasing?

    Science.gov (United States)

    Andriole, Dorothy A; Jeffe, Donna B; Schechtman, Kenneth B

    2007-03-01

    We sought to determine the extent to which recent increases in levels of gender and racial diversity in the overall resident-physician workforce were evident among core-surgical specialty resident workforces. Chi-square tests for trend assessed the importance of changes from 1996 to 2004 in proportions of women and African Americans in the surgery-resident workforce. Surgery-resident trends were compared with overall resident workforce trends using two-tailed t-tests to compare regression slopes that quantified rates of change over time. Chi-square tests assessed differences between proportions of women and African Americans in the current overall board-certified workforce and their proportions in the surgery board-certified workforce. From 1996 to 2004, proportions of women increased in all seven surgical specialties studied. Compared with the overall trend toward increasing proportions of women in the resident workforce, the trend in one surgical specialty was larger (obstetrics/gynecology, p 0.05), and two were smaller (each p 0.05). Proportions of African Americans decreased in three specialties (each p workforce, except obstetrics/gynecology, remained lower than in the overall board-certified workforce (each p workforces have persisted since 1996 and will likely perpetuate ongoing surgery board-certified workforce disparities.

  4. Cross-cultural adaptation of the assistive technology device - Predisposition assessment (ATD PA) for use in Brazil (ATD PA Br).

    Science.gov (United States)

    Alves, Ana Cristina de Jesus; Matsukura, Thelma Simões; Scherer, Marcia J

    2017-02-01

    The purpose of this study is to conduct a cross-cultural adaptation of the Assistive Technology Device Predisposition Assessment (ATD PA) for use in Brazil. The selection of the Assistive Technology Device Predisposition Assessment (ATD PA) was determined by previous literature reviews of articles published in 2014 and 2016 in six databases with the terms "assistive device" or "assistive technology" or "self-help device" combined with "evidence-based practice" or "framework" or "measurement scale" or "model and outcome assessment". This review indicated that the conceptual model of Assistive Technology (AT) most discussed in the literature was the Matching Person and Technology (MPT) model, and this finding determined the selection of ATD PA as an assessment within the MPT portfolio of measures. The procedures for cross-cultural adaptation were as follows: Equivalence of Concept, Semantic and Operational. Five experts were asked to translate 725 items and these translations were evaluated and a high level of agreement was demonstrated. The Portuguese version, Avaliação de Tecnologia Assistiva - Predisposição ao Uso - ATD PA Br, was derived from the original version in English (ATD PA). The ATD PA Br will support professionals and people with disabilities in Brazil to better select AT devices according to the clients' needs. Implications for rehabilitation Provides a systematic way of selecting assistive technology devices for the use of individuals with disabilities according to the Brazilian reality. A systematic way of selecting the assistive technology that can help decrease the abandonment of the assistive technology use. The use of the Matching Person and Technology theorical model and of the assessment ATD PA Br is essential to guide the researches and clinical practice in Brazil.

  5. Ultrasound assessment of the Essure contraceptive devices: is three-dimensional ultrasound really needed?

    Science.gov (United States)

    Paladini, Dario; Di Spiezio Sardo, Attilio; Coppola, Carmela; Zizolfi, Brunella; Pastore, Gaetano; Nappi, Carmine

    2015-01-01

    To evaluate the feasibility of 3-dimensional ultrasound (3DUS) for sonographic localization of Essure microinserts, comparing it with 2-dimensional ultrasound (2DUS) insofar as time to visualize the inserts and accuracy in determining their localization. Prospective study (Canadian Task Force classification II-2). University clinic. Twenty-seven consecutive women undergoing hysteroscopic Essure device placement. Essure microinserts were inserted in the outpatient hysteroscopy clinic following the manufacturer's recommendations, leaving from 3 to 8 loops of the inserts in the uterine cavity. In all patients, 2DUS and 3DUS were performed 3 months after the procedure. 2DUS was performed first; the device(s) were located, and their position was recorded. Then 3DUS scans were acquired, trying when possible to have both devices at least at a 45-degree angle with the insonation beam for optimal rendering on 3DUS. The OmniView method with volume contrast imaging was used to show the relationships of the microinserts within the uterine cavity when possible. To define the position of the Essure device in relation to the uterus and the salpinges, we used the classification developed by Legendre and colleagues. After sonographic evaluation all women underwent hysterosalpingography to assess the success of sterilization. Hysteroscopic insertion was successful in all patients, with 2 Essure devices placed in 25 patients and 1 device in 2 patients (due to previous salpingectomy performed because of ectopic pregnancy), for a total of 52 devices. One spontaneous late (within 3 months) expulsion of the device occurred; the device had migrated almost completely into the uterine cavity. At 3-month follow-up, all 51 correctly placed devices were easily observed at 2DUS (mean [SD] duration of the procedure, 2.25 [0.8] minutes). At 3DUS in 51 cases, the device was in perfect position (1+2+3) in 21 (41.2%), in position 2+3 in 14 (27.4%), and in position +3 in 16 (31.4%). Both microinserts

  6. Differences between Mothers' and Fathers' Ratings of Family Functioning with the Family Assessment Device: The Validity of Combined Parent Scores

    Science.gov (United States)

    Cooke, Dawson; Marais, Ida; Cavanagh, Robert; Kendall, Garth; Priddis, Lynn

    2015-01-01

    The psychometric properties of the General Functioning subscale of the McMaster Family Assessment Device were examined using the Rasch Model (N = 237 couples). Mothers' and fathers' ratings of the General Functioning subscale of the McMaster Family Assessment Device are recommended, provided these are analyzed separately. More than a quarter of…

  7. A Randomized Controlled Trial to Assess the Effects of Competition on the Development of Laparoscopic Surgical Skills.

    Science.gov (United States)

    Hashimoto, Daniel A; Gomez, Ernest D; Beyer-Berjot, Laura; Khajuria, Ankur; Williams, Noel N; Darzi, Ara; Aggarwal, Rajesh

    2015-01-01

    Serious games have demonstrated efficacy in improving participation in surgical training activities, but studies have not yet demonstrated the effect of serious gaming on performance. This study investigated whether competitive training (CT) affects laparoscopic surgical performance. A total of 20 novices were recruited, and 18 (2 dropouts) were randomized into control or CT groups to perform 10 virtual reality laparoscopic cholecystectomies (LCs). Competitiveness of each participant was assessed. The CT group members were informed they were competing to outperform one another for a prize; performance ranking was shown before each session. The control group did not compete. Performance was assessed on time, movements, and instrument path length. Quality of performance was assessed with a global rating scale score. There were no significant intergroup differences in baseline skill or measured competitiveness. Time and global rating scale score, at final LC, were not significantly different between groups; however, the CT group was significantly more dexterous than control and had significantly lower variance in number of movements and instrument path length at the final LC (p = 0.019). Contentiousness was inversely related to time in the CT group. This was the first randomized controlled trial to investigate if CT can enhance performance in laparoscopic surgery. CT may lead to improved dexterity in laparoscopic surgery but yields otherwise similar performance to that of standard training in novices. Competition may have different effects on novices vs experienced surgeons, and subsequent research should investigate CT in experienced surgeons as well. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  8. Pre-surgical register of tobacco consumption.

    Science.gov (United States)

    Gavilán, Eva; Moreno, Montse; Pérez, Àngels; Castellano, Yolanda; Fernández, Esteve; Martínez, Cristina

    2018-03-24

    Smoking cessation before surgery decreases the risk of complications. The aim of this study was to analyse the smoking register, associated variables and a short talk given to smokers in pre-surgical visits. Cross-sectional study. The pre-surgical records of 680 patients were assessed. We selected patient sociodemographic variables, surgical intervention characteristics, smoking status and consumption pattern. Logistic regression was used to study the variables association with smoking. A percentage of 97.2 of the pre-surgical records include information on tobacco consumption. Overall 20% of surgical patients are smokers. The probability of smoking is higher among men (adjusted odds ratio [aOR] 2.6, 95% confidence interval [CI] 1.7-4.0) and≤60 years (aOR 5.4, 95% CI 3.2-9.1). None of the records had information regarding a short talk given to patients to give up smoking. Smoking consumption was prevalent, but the characterisation of a smoker's profile and short talk given to patient before surgery was practically nonexistent. Ensuring that patients who smokes receives a short talk to give up smoking before surgery is necessary. Copyright © 2018 Elsevier España, S.L.U. All rights reserved.

  9. Design of a factorial experiment with randomization restrictions to assess medical device performance on vascular tissue.

    Science.gov (United States)

    Diestelkamp, Wiebke S; Krane, Carissa M; Pinnell, Margaret F

    2011-05-20

    Energy-based surgical scalpels are designed to efficiently transect and seal blood vessels using thermal energy to promote protein denaturation and coagulation. Assessment and design improvement of ultrasonic scalpel performance relies on both in vivo and ex vivo testing. The objective of this work was to design and implement a robust, experimental test matrix with randomization restrictions and predictive statistical power, which allowed for identification of those experimental variables that may affect the quality of the seal obtained ex vivo. The design of the experiment included three factors: temperature (two levels); the type of solution used to perfuse the artery during transection (three types); and artery type (two types) resulting in a total of twelve possible treatment combinations. Burst pressures of porcine carotid and renal arteries sealed ex vivo were assigned as the response variable. The experimental test matrix was designed and carried out as a split-plot experiment in order to assess the contributions of several variables and their interactions while accounting for randomization restrictions present in the experimental setup. The statistical software package SAS was utilized and PROC MIXED was used to account for the randomization restrictions in the split-plot design. The combination of temperature, solution, and vessel type had a statistically significant impact on seal quality. The design and implementation of a split-plot experimental test-matrix provided a mechanism for addressing the existing technical randomization restrictions of ex vivo ultrasonic scalpel performance testing, while preserving the ability to examine the potential effects of independent factors or variables. This method for generating the experimental design and the statistical analyses of the resulting data are adaptable to a wide variety of experimental problems involving large-scale tissue-based studies of medical or experimental device efficacy and performance.

  10. Dynamics of device innovation: implications for assessing value.

    Science.gov (United States)

    Gelijns, Annetine C; Russo, Mark J; Hong, Kimberly N; Brown, Lawrence D; Ascheim, Deborah D; Moskowitz, Alan J

    2013-10-01

    In recent years, there has been growing interest in evaluating the health and economic impact of medical devices. Payers increasingly rely on cost-effectiveness analyses in making their coverage decisions, and are adopting value-based purchasing initiatives. These analytic approaches, however, have been shaped heavily by their use in the pharmaceutical realm, and are ill-adapted to the medical device context. This study focuses on the development and evaluation of left ventricular assist devices (LVADs) to highlight the unique challenges involved in the design and conduct of device trials compared with pharmaceuticals. Devices are moving targets characterized by a much higher degree of post-introduction innovation and "learning by using" than pharmaceuticals. The cost effectiveness ratio of left ventricular assist devices for destination therapy, for example, decreased from around $600,000 per life year saved based on results from the pivotal trial to around $100,000 within a relatively short time period. These dynamics pose fundamental challenges to the evaluation enterprise as well as the policy-making world, which this paper addresses.

  11. Assessment of surgical and obstetrical care at 10 district hospitals in Ghana using on-site interviews.

    Science.gov (United States)

    Abdullah, Fizan; Choo, Shelly; Hesse, Afua A J; Abantanga, Francis; Sory, Elias; Osen, Hayley; Ng, Julie; McCord, Colin W; Cherian, Meena; Fleischer-Djoleto, Charles; Perry, Henry

    2011-12-01

    For most of the population in Africa, district hospitals represent the first level of access for emergency and essential surgical services. The present study documents the number and availability of surgical and obstetrical care providers as well as the types of surgical and obstetrical procedures being performed at 10 first-referral district hospitals in Ghana. After institutional review board and governmental approval, a study team composed of Ghanaian and American surgeons performed on-site surveys at 10 district hospitals in 10 different regions of Ghana in August 2009. Face-to-face interviews were conducted documenting the numbers and availability of surgical and obstetrical personnel as well as gathering data relating to the number and types of procedures being performed at the facilities. A total of 68 surgical and obstetrical providers were interviewed. Surgical and obstetrical care providers consisted of Medical Officers (8.5%), nurse anesthetists (6%), theatre nurses (33%), midwives (50.7%), and others (4.5%). Major surgical cases represented 37% of overall case volumes with cesarean section as the most common type of major surgical procedure performed. The most common minor surgical procedures performed were suturing of lacerations or episiotomies. The present study demonstrates that there is a substantial shortage of adequately trained surgeons who can perform surgical and obstetrical procedures at first-referral facilities. Addressing human resource needs and further defining practice constraints at the district hospital level are important facets of future planning and policy implementation. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. Surgical lighting

    NARCIS (Netherlands)

    Knulst, A.J.

    2017-01-01

    The surgical light is an important tool for surgeons to create and maintain good visibility on the surgical task. Chapter 1 gives background to the field of (surgical) lighting and related terminology. Although the surgical light has been developed strongly since its introduction a long time ago,

  13. Surgical smoke.

    Science.gov (United States)

    Fan, Joe King-Man; Chan, Fion Siu-Yin; Chu, Kent-Man

    2009-10-01

    Surgical smoke is the gaseous by-product formed during surgical procedures. Most surgeons, operating theatre staff and administrators are unaware of its potential health risks. Surgical smoke is produced by various surgical instruments including those used in electrocautery, lasers, ultrasonic scalpels, high speed drills, burrs and saws. The potential risks include carbon monoxide toxicity to the patient undergoing a laparoscopic operation, pulmonary fibrosis induced by non-viable particles, and transmission of infectious diseases like human papilloma virus. Cytotoxicity and mutagenicity are other concerns. Minimisation of the production of surgical smoke and modification of any evacuation systems are possible solutions. In general, a surgical mask can provide more than 90% protection to exposure to surgical smoke; however, in most circumstances it cannot provide air-tight protection to the user. An at least N95 grade or equivalent respirator offers the best protection against surgical smoke, but whether such protection is necessary is currently unknown.

  14. Surgical instruction for general practitioners: how, who and how often?

    LENUS (Irish Health Repository)

    Collins, Anne M

    2010-07-01

    Educational programmes, designed to meet the training needs of General Practitioners (GPs) performing minor surgical procedures, have previously been shown to increase their surgical workload. The change in the level of competence following these programmes has not been assessed. The aims of this study were two-fold: to evaluate the vertical mattress suture for construct validity and to assess the impact of plastic surgery training on the surgical skill of GPs. Thirty non-consultant hospital doctors and 27 self-selected GPs were included. Using a modified objective structured assessment of technical skills (OSATS) scoring system, construct validity of the vertical mattress suture was confirmed. The median total OSATS score was 16 points (26.7%) in the novice group (medical registrars), 38.5 points (64.2%) in the intermediate group (surgical SHOs) and 59 points (98.3%) in the expert group (surgical registrars, p<0.001, Kruskal-Wallis test). Objective assessment in the GP group immediately following practical instruction revealed a median overall improvement of 31.7% (19 points) in total OSATS scores (p<0.001, Friedman non-parametric test, F). At six months follow-up all course participants had improved compared to their baseline. A median overall improvement of 13 points (21.7%) was noted (p<0.001, F). However, the majority (80%, n=20) had deteriorated from the standard set immediately after the course with a median overall reduction in total OSATS scores of six points (10%, p=0.001, F). Plastic surgery training is immediately efficacious in improving the technical proficiency of GPs. Through objective assessment of a standardised suture task we demonstrated a low rate of educational decay of 10% over a six-month period.

  15. Consumer assessment of healthcare providers and systems surgical care survey: benefits and challenges.

    Science.gov (United States)

    Schulz, Kristine A; Rhee, John S; Brereton, Jean M; Zema, Carla L; Witsell, David L

    2012-10-01

    To describe the feasibility and initial results of the implementation of a continuous quality improvement project using the newly available Consumer Assessment of Healthcare Providers and Systems Surgical Care Survey (S-CAHPS), in a small cohort of otolaryngology-head and neck surgery practices. Prospective observational study using a newly validated health care consumer survey. Two community-based and 2 university-based otolaryngology-head and neck surgery outpatient clinic practices. Fourteen board-certified otolaryngology, head and neck surgeons from 4 practice sites voluntarily participated in this project. All adult patients scheduled for surgery during a 12-month period were asked to complete the S-CAHPS survey through an electronic data capture (EDC) system 7 to 28 days after surgery. The surgeons were not directly involved in administration or collection of survey data. Three sites successfully implemented the S-CAHPS project. A 39.9% response rate was achieved for the cohort of surgical patients entered into the EDC system. While most patients rated their surgeons very high (mean of 9.5 or greater out of 10), subanalysis revealed there is variability among sites and surgeons in communication practices. From these data, a potential surgeon Quality Improvement report was developed that highlights priority areas to improve surgeon-patient rapport. The S-CAHPS survey can be successfully implemented in most otolaryngology practices, and our initial work holds promise for how the survey can be best deployed and analyzed for the betterment of both the surgeon and the patient.

  16. New Monitoring Technology to Objectively Assess Adherence to Prescribed Footwear and Assistive Devices During Ambulatory Activity

    NARCIS (Netherlands)

    Bus, Sicco A.; Waaijman, Roelof; Nollet, Frans

    2012-01-01

    Bus SA, Waaijman R, Nollet F. New monitoring technology to objectively assess adherence to prescribed footwear and assistive devices during ambulatory activity. Arch Phys Med Rehabil 2012;93:2075-9. Objective: To assess the validity and feasibility of a new temperature-based adherence monitor to

  17. A practical method for the maintainability assessment in industrial devices using indicators and specific attributes

    International Nuclear Information System (INIS)

    Moreu De Leon, Pedro; González-Prida Díaz, Vicente; Barberá Martínez, Luis; Crespo Márquez, Adolfo

    2012-01-01

    The objective of this paper is to describe a procedure to obtain maintainability indicators for industrial devices. This analysis can be helpful, among other cases, to compare systems, to achieve a better design regarding maintainability requirements, to improve this maintainability under specific industrial environment and to foresee maintainability problems due to eventual changes in a device operation conditions. This maintainability assessment can be carried out at any stage of the industrial asset life cycle. With this purpose, this work first introduces the notion of maintainability and the implementation of assessment indicators, including some important requirements to perform that. Then, a brief literature review is presented, including the definition of the main concepts, which are later used in the paper. After studying the maintenance levels and the maintainability attributes, both terms are linked, leading all this analysis to the assessment of the maintainability indicators. It follows a discussion about the information obtained through the maintainability assessment process and its computation into several maintainability indicators. The paper includes a case study, which implements the defined assessment into a practical scenario. Finally, the work concludes summarizing the more significant aspects and suggesting future researches.

  18. Joint Improvised-Threat Defeat Agency Needs to Improve Assessment and Documentation of Counter-Improvised Explosive Device Initiatives (Redacted)

    Science.gov (United States)

    2016-08-09

    E XC E L L E N C E Joint Improvised ‑Threat Defeat Agency Needs to Improve Assessment and Documentation of Counter‑ Improvised Explosive Device...USE ONLY DODIG-2016-120 (Project No. D2015-D000AE-0222.000) │ i Results in Brief Joint Improvised ‑Threat Defeat Agency Needs to Improve Assessment and...Documentation of Counter‑ Improvised Explosive Device Initiatives Visit us at www.dodig.mil Objective Our audit objective was to determine whether

  19. Assessing the Decrease in the Surgical Population of the University of Puerto Rico-Affiliated Hospitals.

    Science.gov (United States)

    Cruz, Norma I; Santiago, Elvis; Luque, César

    2017-12-01

    To evaluate the magnitude of the decrease in the surgical population of the University of Puerto Rico (UPR)-affiliated hospitals. We examined all the surgical cases that were entered into the Surgical Database from January 1, 2013, through December 31, 2015. This database collects patient and procedural information from the surgical services of the UPR-affiliated hospitals. Thus, the number of surgical patients for the 3-year study period was determined and their characteristics recorded. The group was subdivided into 3 subgroups, according to year: 2013, 2014, and 2015. All the variables studied were tabulated for the 3 subgroups and the values compared. The differences between subgroups were evaluated using the chi2 test or ANOVA, whichever was appropriate, with a p-value of less than 0.05 being considered significant. During the 3-year period, the Surgical Database collected information on 14,626 cases. The mean age of the group was 48 (±23) years. The gender distribution indicated that 55% of the sample members were women and 45% were men. A 14% decline in the number of surgical cases occurred from 2013 through 2015. The changes were not limited to a decline in numbers; the patients were sicker, as evidenced by a statistically significant (pPuerto Rico.

  20. Development and evaluation of accessories to improve the posture of veterinary surgeons in surgical procedures conducted in the field

    Directory of Open Access Journals (Sweden)

    V.A.S. Vulcani

    Full Text Available ABSTRACT The study was conducted based on the information collected on rural properties in the state of Goiás, during practical classes of Surgical Clinic in Large Animals at the Veterinary Hospital of the Escola de Veterinária e Zootecnia of the Universidade Federal de Goiás and during the implementation of outreach projects developed by the institution. An acropostite-phimosis surgical procedure in the bulls in the field was selected, lasting over 30 minutes and requiring movements, posture and strength on the part of the surgeon. Devices were proposed and developed to provide improved comfort and safety to surgeons. The first device was a stool to be used by the professional during the execution of the surgical intervention. The use enabled the surgeon to sit down and rest their feet on the ground, reducing knee bending and distributing the support forces in various muscle groups. For the movement restriction of the surgeon, another accessory was developed to support the foreskin of the animal. Made of wood, this other device serves as a support for keeping the foreskin away from the ground and close to the surgeon. Its length, width and thickness established a good relation with the stool height, providing minimal discomfort to the professional. The third device was designed to assist in the immobilization of the animal and increase safety for the patient and surgical team. A fourth accessory was designed to protect the scapular region and avoid the occurrence of injuries in the radial nerve, myopathies and traumas during the rollover or prolonged stay of the animal in lateral decubitus. The choice of the shape, dimensions and softness of the device was mainly based on the weight of the animal. Such devices have proven to be effective, reducing the time of surgery, making cervical and lumbar movement easier, in addition to providing better support to the surgeon, reducing risks of musculoskeletal diseases.

  1. Surgical treatment of unilateral condylar hyperplasia with piezosurgery.

    Science.gov (United States)

    Chiarini, Luigi; Albanese, Massimo; Anesi, Alexandre; Galzignato, Pier-Francesco; Mortellaro, Carmen; Nocini, Pierfrancesco; Bertossi, Dario

    2014-05-01

    Unilateral condylar hyperplasia (UCH) is a disorder of unknown etiology mainly seen in growing patients, which results in facial asymmetry. High condylectomy alone or in association with orthognathic surgery can improve the occlusion and the facial aesthetics. Between 2005 and 2012, a total of 5 patients underwent high condylectomy for UCH using a piezoelectric cutting device. All patients were treated postoperatively with functional rehabilitation. The long-term follow-up showed that all patients had a satisfactory temporomandibular joint articular function associated with stable occlusion without any recurrence of further condylar growth. High condylectomy in the surgical treatment of unilateral UCH seems to be the procedure of choice in growing patients. The use of a piezoelectric cutting device allows a safe and less invasive high condylectomy.

  2. Dual in vivo Photoacoustic and Fluorescence Imaging of HER2 Expression in Breast Tumors for Diagnosis, Margin Assessment, and Surgical Guidance

    Directory of Open Access Journals (Sweden)

    Azusa Maeda

    2015-01-01

    Full Text Available Biomarker-specific imaging probes offer ways to improve molecular diagnosis, intraoperative margin assessment, and tumor resection. Fluorescence and photoacoustic imaging probes are of particular interest for clinical applications because the combination enables deeper tissue penetration for tumor detection while maintaining imaging sensitivity compared to a single optical imaging modality. Here we describe the development of a human epidermal growth factor receptor 2 (HER2-targeting imaging probe to visualize differential levels of HER2 expression in a breast cancer model. Specifically, we labeled trastuzumab with Black Hole Quencher 3 (BHQ3 and fluorescein for photoacoustic and fluorescence imaging of HER2 overexpression, respectively. The dual-labeled trastuzumab was tested for its ability to detect HER2 overexpression in vitro and in vivo. We demonstrated an over twofold increase in the signal intensity for HER2-overexpressing tumors in vivo, compared to low–HER2-expressing tumors, using photoacoustic imaging. Furthermore, we demonstrated the feasibility of detecting tumors and positive surgical margins by fluorescence imaging. These results suggest that multimodal HER2-specific imaging of breast cancer using the BHQ3-fluorescein trastuzumab enables molecular-level detection and surgical margin assessment of breast tumors in vivo. This technique may have future clinical impact for primary lesion detection, as well as intraoperative molecular-level surgical guidance in breast cancer.

  3. Systems for tracking minimally invasive surgical instruments.

    Science.gov (United States)

    Chmarra, M K; Grimbergen, C A; Dankelman, J

    2007-01-01

    Minimally invasive surgery (e.g. laparoscopy) requires special surgical skills, which should be objectively assessed. Several studies have shown that motion analysis is a valuable assessment tool of basic surgical skills in laparoscopy. However, to use motion analysis as the assessment tool, it is necessary to track and record the motions of laparoscopic instruments. This article describes the state of the art in research on tracking systems for laparoscopy. It gives an overview on existing systems, on how these systems work, their advantages, and their shortcomings. Although various approaches have been used, none of the tracking systems to date comes out as clearly superior. A great number of systems can be used in training environment only, most systems do not allow the use of real laparoscopic instruments, and only a small number of systems provide force feedback.

  4. The use of a new automatic device for patients' assessment at Triage in Emergency Department

    Directory of Open Access Journals (Sweden)

    Salvatore Di Somma

    2013-06-01

    Full Text Available Objectives: To assess time saving in an Emergency Department arising out of the introduction of automatic devices (Carescape™ V100 to measure vital signs compared to the manual devices. Methods: We performed a prospective, observational study of eligible patients referring to Sant’Andrea Hospital Emergency Department during the entire month of October 2009, randomly assigned into two groups. In the first group of 476 patients vital signs measurements were detected with manual devices, while in the second group of 477 patients with automatic device Carescape™ V100. Results: Data indicated that the comparison of the total time between the two groups gave a significant difference (1993 vs 1518 min, p < 0.001. No differences were found with respect to age, sex and priority codes. Significant differences were also found when comparing the subgroups of the same acuity categories: white codes 4.33 vs 2.27 (min, p < 0.05; green codes 4.28 vs 3.37 (min, p < 0.001; yellow codes 3.92 vs 2.72 (min, p < 0.001. Conclusions: Our data demonstrated a statistical significance between the two groups with a difference of 475 minutes spent in Triage procedures including vital signs measurements. In conclusion time saved by vital signs automatic device could allow ED physicians to make a qualified approach with an earlier diagnosis and a more rapid and effective therapy, possibly improving patients’ outcomes. ABSTRACT of data concerning vital signs quality assessment, because we did not compare the two methods in the same patient and we did not correlate Triage priority evaluation with patients’ outcomes. In the future further studies should be specifically aimed to address this issue. In conclusion time saved by vital signs automatic device could allow ED physicians to make a qualified approach to patient with an earlier diagnosis and a more rapid and effective therapy, possibly improving patients’ outcomes.

  5. Surgical Treatment of Perianal Fistulizing Crohn’s Disease: From Lay-Open to Cell-Based Therapy—An Overview

    Directory of Open Access Journals (Sweden)

    Gianluca Pellino

    2014-01-01

    Full Text Available Background. Perianal Crohn’s disease (CD can be challenging. Despite the high incidence of fistulizing CD, literature lacks clear guidelines. Several medical, surgical, and combined treatment modalities have been proposed, but evidences are scarce. Methods. We searched the literature to assess the facets of perianal CD, with particular focus on complex fistulae. Disease epidemiology, classification, diagnosis, activity scoring systems, and medical-surgical treatments were assessed. Results. Perianal fistulizing CD is common, frequently associated with upper gastrointestinal and colorectal CD. Complex fistulas often require repeated treatments. Continence is a major concern when dealing with repeated procedures. A prudent pathway is to resolve active sepsis and to limit damages, delaying a definitive treatment to the time when acute phase has been controlled. The improved diagnostic techniques allow better preoperative planning and are useful in monitoring the response to treatment. Besides newer devices, cell-based treatments are promising tools which have recently enriched the treatment portfolio. However, the need for proctectomy is still disturbingly high in CD patients with complex perianal fistulae. Conclusions. Perianal CD can impair quality of life and lead to need for proctectomy. A staged approach is reasonable. Treatment success can be improved by multimodal treatment and collaborative management by experienced gastroenterologists and surgeons.

  6. Eagle syndrome surgical treatment with piezosurgery.

    Science.gov (United States)

    Bertossi, Dario; Albanese, Massimo; Chiarini, Luigi; Corega, Claudia; Mortellaro, Carmen; Nocini, Pierfrancesco

    2014-05-01

    Eagle syndrome (ES) is an uncommon complication of styloid process elongation with stylohyoideal complex symptomatic calcification. It is an uncommon condition (4% of the population) that is symptomatic in only 4% of the cases. Eagle syndrome is usually an acquired condition that can be related to tonsillectomy or to a neck trauma. A type of ES is the styloid-carotid syndrome, a consequence of the irritation of pericarotid sympathetic fibers and compression on the carotid artery. Clinical manifestations are found most frequently after head turning and neck compression. Although conservative treatment (analgesics, anticonvulsants, antidepressants, local infiltration with steroids, or anesthetic agents) have been used, surgical treatment is often the only effective treatment in symptomatic cases. We present the case of a 55-year-old patient, successfully treated under endotracheal anesthesia. The cranial portion of the calcified styloid process was shortened through an external approach, using a piezoelectric cutting device (Piezosurgery Medical II; Mectron Medical Technology, Carasco, Italy) with MT1-10 insert, pump level 4, vibration level 7. No major postoperative complications such as nerve damage, hematoma, or wound dehiscence occurred. After 6 months, the patient was completely recovered. Two years after the surgery, the patient did not refer any symptoms related to ES. The transcervical surgical approach in patients with ES seems to be safe and effective, despite the remarkable risk for transient marginal mandibular nerve palsy. This risk can be decreased by the use of the piezoelectric device for its distinctive characteristics--such as precision, selective cut action, and bloodless cut.

  7. Quality improvement initiative: Preventative Surgical Site Infection Protocol in Vascular Surgery.

    Science.gov (United States)

    Parizh, David; Ascher, Enrico; Raza Rizvi, Syed Ali; Hingorani, Anil; Amaturo, Michael; Johnson, Eric

    2018-02-01

    Objective A quality improvement initiative was employed to decrease single institution surgical site infection rate in open lower extremity revascularization procedures. In an attempt to lower patient morbidity, we developed and implemented the Preventative Surgical Site Infection Protocol in Vascular Surgery. Surgical site infections lead to prolonged hospital stays, adjunctive procedure, and additive costs. We employed targeted interventions to address the common risk factors that predispose patients to post-operative complications. Methods Retrospective review was performed between 2012 and 2016 for all surgical site infections after revascularization procedures of the lower extremity. A quality improvement protocol was initiated in January 2015. Primary outcome was the assessment of surgical site infection rate reduction in the pre-protocol vs. post-protocol era. Secondary outcomes evaluated patient demographics, closure method, perioperative antibiotic coverage, and management outcomes. Results Implementation of the protocol decreased the surgical site infection rate from 6.4% to 1.6% p = 0.0137). Patient demographics and comorbidities were assessed and failed to demonstrate a statistically significant difference among the infection and no-infection groups. Wound closure with monocryl suture vs. staple proved to be associated with decreased surgical site infection rate ( p site infections in the vascular surgery population are effective and necessary. Our data suggest that there may be benefit in the incorporation of MRSA and Gram-negative coverage as part of the Surgical Care Improvement Project perioperative guidelines.

  8. Computer-aided surgical planner for a new bone deformity correction device using axis-angle representation.

    Science.gov (United States)

    Wu, Ying Ying; Plakseychuk, Anton; Shimada, Kenji

    2014-11-01

    Current external fixators for distraction osteogenesis (DO) are unable to correct all types of deformities in the lower limb and are difficult to use because of the lack of a pre-surgical planning system. We propose a DO system that consists of a surgical planner and a new, easy-to-setup unilateral fixator that not only corrects all lower limb deformity, but also generates the contralateral/predefined bone shape. Conventionally, bulky constructs with six or more joints (six degrees of freedom, 6DOF) are needed to correct a 3D deformity. By applying the axis-angle representation, we can achieve that with a compact construct with only two joints (2DOF). The proposed system makes use of computer-aided design software and computational methods to plan and simulate the planned procedure. Results of our stress analysis suggest that the stiffness of our proposed fixator is comparable to that of the Orthofix unilateral external fixator. We tested the surgical system on a model of an adult deformed tibia and the resulting bone trajectory deviates from the target bone trajectory by 1.8mm, which is below our defined threshold error of 2mm. We also extracted the transformation matrix that defines the deformity from the bone model and simulated the planned procedure. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  9. Surgical Assisting

    Science.gov (United States)

    ... instruction, including: Microbiology Pathophysiology Pharmacology Anatomy and physiology Medical terminology Curriculum . Course content includes: Advanced surgical anatomy Surgical microbiology Surgical pharmacology Anesthesia methods and agents Bioscience Ethical ...

  10. Paediatric Abdominal Surgical Emergencies in a General Surgical ...

    African Journals Online (AJOL)

    ... organized for general surgeons undertaking paediatric surgical emergencies. More paediatric surgeons should be trained and more paediatric surgical units should established in the country. Key Words: Paediatric Abdominal Surgical Emergencies; Paediatric Surgeons, General Surgeons. Journal of College of Medicine ...

  11. Shoulder morbidity after non-surgical treatment of the neck

    International Nuclear Information System (INIS)

    Wouwe, Merian van; Bree, Remco de; Kuik, Dirk J.; Goede, Cees J.T. de; Verdonck-de Leeuw, Irma M.; Doornaert, Patricia; Rene Leemans, C.

    2009-01-01

    Background and purpose: Reports on shoulder function after non-surgical treatment are not available. In the present study shoulder morbidity after surgical and non-surgical treatment of the neck is determined and compared. Materials and methods: In 100 head and neck cancer patients 174 neck sides were treated by surgery (n = 51) or (chemo)radiation (n = 123). Abduction, anteflexion, endorotation and exorotation were assessed. Subjective measurements were performed using the Visual Analogue Scale for pain, the Shoulder Disability Questionnaire (SDQ) and stiffness reporting. Results: Predictive factors for SDQ-score > 0 (n = 54) were VAS pain score, stiffness, abduction, anteflexion, physiotherapy, low shoulder position and surgical treatment. The SDQ, stiffness and pain scores were significantly higher in the surgically treated group than in the non-surgical group (p < 0.01). Anteflexion, abduction and exorotation were less impaired in the non-surgically treated group than in the surgically treated group (p < 0.01). No differences between neck dissection and neck dissection with post-operative radiotherapy, and radiotherapy and chemoradiation were found for these movements. Conclusions: Shoulder morbidity is often present after non-surgical treatment of the neck, but to a lesser extent compared to surgical treatment. Radiotherapy adds no morbidity to neck dissection and chemotherapy does not add extra morbidity to primary radiation

  12. 76 FR 12742 - Guidance for Industry and Food and Drug Administration Staff; Clinical Investigations of Devices...

    Science.gov (United States)

    2011-03-08

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2008-D-0457] Guidance for Industry and Food and Drug Administration Staff; Clinical Investigations of Devices Indicated... other electrical continence devices; protective garment for incontinence; surgical mesh; electrosurgical...

  13. Strengthening Your Surgical Hand: Strengths-Based Profiling and Coaching of Surgical Trainees

    Directory of Open Access Journals (Sweden)

    D.A.L. Macafee

    2012-01-01

    Full Text Available Introduction As scientific and professional disciplines, medicine and surgery have a tendency to focus on deficiencies, namely what trainees do not know or are not good at doing. The philosophy of Positive Psychology and the notion of “Strengths” takes a different stance. It is an inherently positive process, seeing each trainee as an individual bringing a unique set of strengths to every situation. There is clear evidence from the commercial sector regarding improved performance and well-being when focusing on one's strengths. We were therefore keen to investigate its potential role in the global development of trainee surgeons. Methods Surgical trainees from Core Training 1 to Specialty Training 8 in one training region of the United Kingdom were invited to voluntarily undertake the online Strengthscope™ assessment tool. The computer-generated report was reviewed by an Occupational Psychologist and trainees were then invited to have a strengths-focused feedback discussion on that report, either face-to-face or via telephone. Results Thirty four surgical trainees ranging from CT1 to ST6 completed the tool and 28 undertook the voluntary feedback sessions. Decisiveness, self-improvement, efficiency, emotional control and critical thinking were common strengths identified. Less commonly represented were leading, creativity and developing others. Trainees found that the tool and feedback helped them identify their strengths and embrace them, rather than fitting the surgical mould. It further aided the recognition of strengths in-overdrive and for some trainees it helped explain difficulties they had experienced in previous jobs. It provided insight into individual motivations and character whilst also highlighting how others in the workplace might perceive them. Trainees liked the emphasis on the building up of positive attributes and utilizing innate skills and strengths. The feedback consultation from an accredited coach trained in the

  14. Linking the Regulatory and Reimbursement Processes for Medical Devices : The Need for Integrated Assessments

    NARCIS (Netherlands)

    Ciani, Oriana; Wilcher, Britni; van Giessen, Anoukh; Taylor, Rod S.

    2017-01-01

    Much criticism has been directed at the licencing requirements for medical devices (MDs) as they often result in a lack of robust evidence to inform health technology assessment (HTA) decisions. To better understand the current international decisional framework on MD technologies, we undertook

  15. Assessment of a Newly Developed, Active Pneumatic-Driven, Sensorimotor Test and Training Device

    Directory of Open Access Journals (Sweden)

    Wolfram Haslinger

    2014-12-01

    Full Text Available The sensorimotor system (SMS plays an important role in sports and in every day movement. Several tools for assessment and training have been designed. Many of them are directed to specific populations, and have major shortcomings due to the training effect or safety. The aim of the present study was to design and assess a dynamic sensorimotor test and training device that can be adjusted for all levels of performance. The novel pneumatic-driven mechatronic device can guide the trainee, allow independent movements or disrupt the individual with unpredicted perturbations while standing on a platform. The test-reliability was evaluated using intraclass correlation coefficient (ICC. Subjects were required to balance their center of pressure (COP in a target circle (TITC. The time in TITC and the COP error (COPe were recorded for analysis. The results of 22 males and 14 females (23.7 ± 2.6 years showed good to excellent test–retest reliability. The newly designed Active Balance System (ABS was then compared with the Biodex Balance System SD® (BBS. The results of 15 females, 14 males (23.4 ± 1.6 years showed modest correlation in static and acceptable correlation in dynamic conditions, suggesting that ABS could be a reliable and comparable tool for dynamic balance assessments.

  16. An advanced simulator for orthopedic surgical training.

    Science.gov (United States)

    Cecil, J; Gupta, Avinash; Pirela-Cruz, Miguel

    2018-02-01

    The purpose of creating the virtual reality (VR) simulator is to facilitate and supplement the training opportunities provided to orthopedic residents. The use of VR simulators has increased rapidly in the field of medical surgery for training purposes. This paper discusses the creation of the virtual surgical environment (VSE) for training residents in an orthopedic surgical process called less invasive stabilization system (LISS) surgery which is used to address fractures of the femur. The overall methodology included first obtaining an understanding of the LISS plating process through interactions with expert orthopedic surgeons and developing the information centric models. The information centric models provided a structured basis to design and build the simulator. Subsequently, the haptic-based simulator was built. Finally, the learning assessments were conducted in a medical school. The results from the learning assessments confirm the effectiveness of the VSE for teaching medical residents and students. The scope of the assessment was to ensure (1) the correctness and (2) the usefulness of the VSE. Out of 37 residents/students who participated in the test, 32 showed improvements in their understanding of the LISS plating surgical process. A majority of participants were satisfied with the use of teaching Avatars and haptic technology. A paired t test was conducted to test the statistical significance of the assessment data which showed that the data were statistically significant. This paper demonstrates the usefulness of adopting information centric modeling approach in the design and development of the simulator. The assessment results underscore the potential of using VR-based simulators in medical education especially in orthopedic surgery.

  17. Assessing symmetry using the mirror stand device with manual and software-assisted methods in postoperative zygomatic fracture patients

    Science.gov (United States)

    Syarif, A. N.; Bangun, K.

    2017-08-01

    Zygomatic fractures are among the most common fractures to the facial skeleton. However, because no standard and reliable method of evaluation is available to assess postoperative patients, we often rely on photographs and subjective assessments. A portable mirror stand device (MiRS), which is a new method for the standardization of photography, was developed in our institution. Used with image analysis software, this device provides a new method for evaluating outcomes after the open reduction and internal fixation of zygomatic fractures. The portable mirror stand device was set up in our outpatient clinic at the Cleft Craniofacial Center at Cipto Mangunkusumo Hospital. Photographs of 11 postoperative patients were taken using the device, and they were analyzed both manually and using image analysis software (ImageJ 1.46) for symmetry. The two methods were then compared to assess the correlation and agreement of the results. The measurements taken using the manual method and the software-assisted method did not differ significantly, which indicated the good agreement between the two methods. The results of the symmetry achieved atour center were similar to other centers in the Asian region (ΔZy = 3.4±1.5 mm, ΔBc = 2.6±1.6 mm, ΔCh = 2.3±2.4 mm) compared with (ΔZy = 3.2±1.7 mm, ΔBc = 2.6±1.6 mm, ΔCh = 2.3±2.5 mm). The treatment of zygomatic fracture a tour center achieved good results. The portable mirror stand device assisted the image analysis software (ImageJ 1.46), which could be beneficial in assessing symmetry in postoperative zygomatic fracture patients.

  18. Interim report on the assessment of engineering issues for compact high-field ignition devices

    International Nuclear Information System (INIS)

    Flanagan, C.A.

    1986-04-01

    The engineering issues addressed at the workshop included the overall configuration, layout, and assembly; limiter and first-wall energy removal; magnet system structure design; fabricability; repairability; and costs. In performing the assessment, the primary features and characteristics of each concept under study were reviewed as representative of this class of ignition device. The emphasis was to understand the key engineering areas of concern for this class of device and deliberately not attempt to define an optimum design or to choose a best approach. The assessment concluded that compact ignition tokamaks, as represented by the three concepts under study, are feasible. A number of critical engineering issues were identified, and all appear to have tractable solutions. The engineering issues appear quite challenging, and to obtain increased confidence in the apparent design solutions requires completion of the next level of design detail, complemented by appropriate development programs and testing

  19. A primer on standards setting as it applies to surgical education and credentialing.

    Science.gov (United States)

    Cendan, Juan; Wier, Daryl; Behrns, Kevin

    2013-07-01

    Surgical technological advances in the past three decades have led to dramatic reductions in the morbidity associated with abdominal procedures and permanently altered the surgical practice landscape. Significant changes continue apace including surgical robotics, natural orifice-based surgery, and single-incision approaches. These disruptive technologies have on occasion been injurious to patients, and high-stakes assessment before adoption of new technologies would be reasonable. We reviewed the drivers for well-established psychometric techniques available for the standards-setting process. We present a series of examples that are relevant in the surgical domain including standards setting for knowledge and skills assessments. Defensible standards for knowledge and procedural skills will likely become part of surgical clinical practice. Understanding the methodology for determining standards should position the surgical community to assist in the process and lead within their clinical settings as standards are considered that may affect patient safety and physician credentialing.

  20. Devices and Endoscopic Bariatric Therapies for Obesity.

    Science.gov (United States)

    Saunders, Katherine H; Igel, Leon I; Saumoy, Monica; Sharaiha, Reem Z; Aronne, Louis J

    2018-04-17

    In this review, we describe the FDA-approved and investigational devices and endoscopic bariatric therapies for the treatment of obesity. We focus on literature published in the past few years and present mechanisms of action as well as efficacy and safety data. Devices and endoscopic procedures are emerging options to fill the significant treatment gap in the management of obesity. Not only are these devices and procedures minimally invasive and reversible, but they are potentially more effective than antiobesity medications, often safer for poor surgical candidates and possibly less expensive than bariatric surgery. As many patients require a variety of management strategies (medications, devices, procedures, and/or surgery) in addition to lifestyle modifications to achieve clinically significant weight loss, the future of obesity treatment involves a multidisciplinary approach. Combinations of advanced treatment strategies can lead to additive or synergistic weight loss. This is an area that requires further investigation.

  1. The role of student surgical interest groups and surgical Olympiads in anatomical and surgical undergraduate training in Russia.

    Science.gov (United States)

    Dydykin, Sergey; Kapitonova, Marina

    2015-01-01

    Traditional department-based surgical interest groups in Russian medical schools are useful tools for student-based selection of specialty training. They also form a nucleus for initiating research activities among undergraduate students. In Russia, the Departments of Topographical Anatomy and Operative Surgery play an important role in initiating student-led research and providing learners with advanced, practical surgical skills. In tandem with department-led activities, student surgical interest groups prepare learners through surgical competitions, known as "Surgical Olympiads," which have been conducted in many Russian centers on a regular basis since 1988. Surgical Olympiads stimulate student interest in the development of surgical skills before graduation and encourage students to choose surgery as their postgraduate specialty. Many of the participants in these surgical Olympiads have become highly qualified specialists in general surgery, orthopedic surgery, neurosurgery, urology, gynecology, and emergency medicine. The present article emphasizes the role of student interest groups and surgical Olympiads in clinical anatomical and surgical undergraduate training in Russia. © 2015 American Association of Anatomists.

  2. Surgically assisted rapid maxillary expansion in adults.

    Science.gov (United States)

    Pogrel, M A; Kaban, L B; Vargervik, K; Baumrind, S

    1992-01-01

    Twelve adults with maxillary width discrepancy of greater than 5 mm were treated by surgically assisted rapid maxillary expansion. The procedure consisted of bilateral zygomatic buttress and midpalatal osteotomies combined with the use of a tooth-borne orthopedic device postoperatively. Mean palatal expansion of 7.5 mm (range of 6 to 13 mm), measured in the first molar region, was achieved within 3 weeks in all patients. Expansion remained stable during the 12-month study period, with a mean relapse for the entire group of 0.88 +/- 0.48 mm. Morbidity was limited to mild postoperative discomfort. The results of this preliminary study indicated that surgically assisted rapid maxillary expansion is a safe, simple, and reliable procedure for achieving a permanent increase in skeletal maxillary width in adults. Further study is necessary to document the three-dimensional movements of the maxillary segments and long-term stability of the skeletal and dental changes.

  3. A Process Improvement Evaluation of Sequential Compression Device Compliance and Effects of Provider Intervention.

    Science.gov (United States)

    Beachler, Jason A; Krueger, Chad A; Johnson, Anthony E

    This process improvement study sought to evaluate the compliance in orthopaedic patients with sequential compression devices and to monitor any improvement in compliance following an educational intervention. All non-intensive care unit orthopaedic primary patients were evaluated at random times and their compliance with sequential compression devices was monitored and recorded. Following a 2-week period of data collection, an educational flyer was displayed in every patient's room and nursing staff held an in-service training event focusing on the importance of sequential compression device use in the surgical patient. Patients were then monitored, again at random, and compliance was recorded. With the addition of a simple flyer and a single in-service on the importance of mechanical compression in the surgical patient, a significant improvement in compliance was documented at the authors' institution from 28% to 59% (p < .0001).

  4. Design, implementation and testing of master slave robotic surgical system

    International Nuclear Information System (INIS)

    Ali, S.A.

    2015-01-01

    The autonomous manipulation of the medical robotics is needed to draw up a complete surgical plan in development. The autonomy of the robot comes from the fact that once the plan is drawn up off-line, it is the servo loops, and only these, that control the actions of the robot online, based on instantaneous control signals and measurements provided by the vision or force sensors. Using only these autonomous techniques in medical and surgical robotics remain relatively limited for two main reasons: Predicting complexity of the gestures, and human Safety. Therefore, Modern research in haptic force feedback in medical robotics is aimed to develop medical robots capable of performing remotely, what a surgeon does by himself. These medical robots are supposed to work exactly in the manner that a surgeon does in daily routine. In this paper the master slave tele-robotic system is designed and implemented with accuracy and stability by using 6DOF (Six Degree of Freedom) haptic force feedback devices. The master slave control strategy, haptic devices integration, application software designing using Visual C++ and experimental setup are considered. Finally, results are presented the stability, accuracy and repeatability of the system. (author)

  5. Design, Implementation and Testing of Master Slave Robotic Surgical System

    Directory of Open Access Journals (Sweden)

    Syed Amjad Ali

    2015-01-01

    Full Text Available The autonomous manipulation of the medical robotics is needed to draw up a complete surgical plan in development. The autonomy of the robot comes from the fact that once the plan is drawn up off-line, it is the servo loops, and only these, that control the actions of the robot online, based on instantaneous control signals and measurements provided by the vision or force sensors. Using only these autonomous techniques in medical and surgical robotics remain relatively limited for two main reasons: Predicting complexity of the gestures, and human Safety. Therefore, Modern research in haptic force feedback in medical robotics is aimed to develop medical robots capable of performing remotely, what a surgeon does by himself. These medical robots are supposed to work exactly in the manner that a surgeon does in daily routine. In this paper the master slave tele-robotic system is designed and implemented with accuracy and stability by using 6DOF (Six Degree of Freedom haptic force feedback devices. The master slave control strategy, haptic devices integration, application software designing using Visual C++ and experimental setup are considered. Finally, results are presented the stability, accuracy and repeatability of the system

  6. The impact of missing sensor information on surgical workflow management.

    Science.gov (United States)

    Liebmann, Philipp; Meixensberger, Jürgen; Wiedemann, Peter; Neumuth, Thomas

    2013-09-01

    Sensor systems in the operating room may encounter intermittent data losses that reduce the performance of surgical workflow management systems (SWFMS). Sensor data loss could impact SWFMS-based decision support, device parameterization, and information presentation. The purpose of this study was to understand the robustness of surgical process models when sensor information is partially missing. SWFMS changes caused by wrong or no data from the sensor system which tracks the progress of a surgical intervention were tested. The individual surgical process models (iSPMs) from 100 different cataract procedures of 3 ophthalmologic surgeons were used to select a randomized subset and create a generalized surgical process model (gSPM). A disjoint subset was selected from the iSPMs and used to simulate the surgical process against the gSPM. The loss of sensor data was simulated by removing some information from one task in the iSPM. The effect of missing sensor data was measured using several metrics: (a) successful relocation of the path in the gSPM, (b) the number of steps to find the converging point, and (c) the perspective with the highest occurrence of unsuccessful path findings. A gSPM built using 30% of the iSPMs successfully found the correct path in 90% of the cases. The most critical sensor data were the information regarding the instrument used by the surgeon. We found that use of a gSPM to provide input data for a SWFMS is robust and can be accurate despite missing sensor data. A surgical workflow management system can provide the surgeon with workflow guidance in the OR for most cases. Sensor systems for surgical process tracking can be evaluated based on the stability and accuracy of functional and spatial operative results.

  7. Attitudes and Perceptions of Surgical Oncology Fellows on ACGME Accreditation and the Complex General Surgical Oncology Certification.

    Science.gov (United States)

    Lee, David Y; Flaherty, Devin C; Lau, Briana J; Deutsch, Gary B; Kirchoff, Daniel D; Huynh, Kelly T; Lee, Ji-Hey; Faries, Mark B; Bilchik, Anton J

    2015-11-01

    With the first qualifying examination administered September 15, 2014, complex general surgical oncology (CGSO) is now a board-certified specialty. We aimed to assess the attitudes and perceptions of current and future surgical oncology fellows regarding the recently instituted Accreditation Council for Graduate Medical Education (ACGME) accreditation. A 29-question anonymous survey was distributed to fellows in surgical oncology fellowship programs and applicants interviewing at our fellowship program. There were 110 responses (79 fellows and 31 candidates). The response rate for the first- and second-year fellows was 66 %. Ninety-percent of the respondents were aware that completing an ACGME-accredited fellowship leads to board eligibility in CGSO. However, the majority (80 %) of the respondents stated that their decision to specialize in surgical oncology was not influenced by the ACGME accreditation. The fellows in training were concerned about the cost of the exam (90 %) and expressed anxiety in preparing for another board exam (83 %). However, the majority of the respondents believed that CGSO board certification will be helpful (79 %) in obtaining their future career goals. Interestingly, candidate fellows appeared more focused on a career in general complex surgical oncology (p = 0.004), highlighting the impact that fellowship training may have on organ-specific subspecialization. The majority of the surveyed surgical oncology fellows and candidates believe that obtaining board certification in CGSO is important and will help them pursue their career goals. However, the decision to specialize in surgical oncology does not appear to be motivated by ACGME accreditation or the new board certification.

  8. Antibiotic prophylaxis adequacy in knee arthroplasty and surgical wound infection: Prospective cohort study.

    Science.gov (United States)

    Del-Moral-Luque, J A; Checa-García, A; López-Hualda, Á; Villar-Del-Campo, M C; Martínez-Martín, J; Moreno-Coronas, F J; Montejo-Sancho, J; Rodríguez-Caravaca, G

    Antibiotic prophylaxis is the most suitable tool for preventing surgical wound infection. This study evaluated adequacy of antibiotic prophylaxis in surgery for knee arthroplasty and its effect on surgical site infection. Prospective cohort study. We assessed the degree of adequacy of antibiotic prophylaxis, the causes of non-adequacy, and the effect of non-adequacy on surgical site infection. Incidence of surgical site infection was studied after a maximum incubation period of a year. To assess the effect of prophylaxis non-adequacy on surgical site infection we used the relative risk adjusted with the aid of a logistic regression model. The study covered a total of 1749 patients. Antibiotic prophylaxis was indicated in all patients and administered in 99.8% of cases, with an overall protocol adequacy of 77.6%. The principal cause of non-compliance was the duration of prescription of the antibiotics (46.5%). Cumulative incidence of surgical site infection was 1.43%. No relationship was found between prophylaxis adequacy and surgical infection (RR=1.15; 95% CI: .31-2.99) (P>.05). Surveillance and infection control programs enable risk factors of infection and improvement measures to be assessed. Monitoring infection rates enables us to reduce their incidence. Adequacy of antibiotic prophylaxis was high but could be improved. We did not find a relationship between prophylaxis adequacy and surgical site infection rate. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. [Change of paradigms in the surgical treatment of complex thoracic aortic disease].

    Science.gov (United States)

    Herold, Ulf; Tsagakis, Konstantinos; Kamler, Markus; Massoudy, Parwis; Assenmacher, Eva; Eggebrecht, Holger; Buck, Thomas; Jakob, Heinz

    2006-08-01

    One of the main issues in complex thoracic aortic disease, requiring the replacement of the ascending aorta, the entire aortic arch and the descending aorta, is the vast amount of surgery necessary to cure the patient. Though one-stage repair is feasible by a clamshell thoracotomy, the associated surgical trauma and perioperative morbidity limit this approach to younger patients only. Classic surgical repair consist of a two-stage strategy, whereby, in the first step, the ascending aorta and the aortic arch are replaced via a midline sternotomy. In the second step, via a lateral thoracotomy, the descending aorta is replaced. The two stages may sum up to a mortality of 20%; furthermore, the waiting period between the stages is associated with a mortality rate of 10% of its own. Additionally, the two-stage strategy has an inherent limitation, due to the comorbidity and advanced age of the majority of patients. Therefore, the second stage cannot be offered to up to 30% of patients. New developments and improvements in aortic surgery were introduced to overcome these shortcomings and to simplify the surgical repair. The "elephant trunk" principle, introduced by Borst et al. in 1983, was an important step to facilitate surgical repair, but still required the second step. With the introduction of endovascular repair of thoracic aortic disease with stent grafts implanted retrograde via the femoral artery, new therapeutic concepts emerged. In the late 1990s, two Japanese groups reported first trials to stabilize the free-floating "elephant trunk" prosthesis by implantation of nitinol stent grafts into the vascular graft. The applied devices were purely custom-made and nonstandardized. The availability of industrially made and CE-marked stent-graft devices raised the possibility to apply them in open aortic arch surgery. The experience with stent-graft devices implanted antegrade into the descending aorta (Medtronic Talent) was reported first by the Essen and the Vienna

  10. Development of a waste management protocol based on assessment of knowledge and practice of healthcare personnel in surgical departments.

    Science.gov (United States)

    Mostafa, Gehan M A; Shazly, Mona M; Sherief, Wafaa I

    2009-01-01

    Good healthcare waste management in a hospital depends on a dedicated waste management team, good administration, careful planning, sound organization, underpinning legislation, adequate financing, and full participation by trained staff. Hence, waste management protocols must be convenient and sensible. To assess the knowledge and practice related to waste management among doctors, nurses, and housekeepers in the surgical departments at Al-Mansoura University Hospital, and to design and validate a waste management protocol for the health team in these settings. This cross-sectional study was carried out in the eight surgical departments at Al-Mansoura University Hospital. All health care personnel and their assistants were included: 38 doctors, 106 nurses, and 56 housekeepers. Two groups of jury were included for experts' opinions validation of the developed protocol, one from academia (30 members) and the other from service providers (30 members). Data were collected using a self-administered knowledge questionnaire for nurses and doctors, and an interview questionnaire for housekeepers. Observation checklists were used for assessment of performance. The researchers developed the first draft of the waste management protocol according to the results of the analysis of the data collected in the assessment phase. Then, the protocol was presented to the jury group for validation, and then was implemented. Only 27.4% of the nurses, 32.1% of the housekeepers, and 36.8% of the doctors had satisfactory knowledge. Concerning practice, 18.9% of the nurses, 7.1% of the housekeepers, and none of the doctors had adequate practice. Nurses' knowledge score had a statistically significant weak positive correlation with the attendance of training courses (r=0.23, pwaste management. The knowledge among nurses is positively affected by attendance of training programs. Based on the findings, a protocol for healthcare waste management was developed and validated. It is recommended to

  11. The extent of environmental and body contamination through aerosols by hydro-surgical debridement in the lumbar spine.

    Science.gov (United States)

    Putzer, David; Lechner, Ricarda; Coraca-Huber, Debora; Mayr, Astrid; Nogler, Michael; Thaler, Martin

    2017-06-01

    Surgical site infections occur in 1-6% of spinal surgeries. Effective treatment includes early diagnosis, parenteral antibiotics and early surgical debridement of the wound surface. On a human cadaver, we executed a complete hydro-surgery debridement including a full surgical setup such as draping. The irrigation fluid was artificially contaminated with Staphylococcus aureus (ATCC 6538). Surveillance cultures were used to detect environmental and body contamination of the surgical team. For both test setups, environmental contamination was observed in an area of 6 × 8 m. Both test setups caused contamination of all personnel present during the procedure and of the whole operating theatre. However, the concentration of contamination for the surgical staff and the environment was lower when an additional disposable draping device was used. The study showed that during hydro-surgery debridement, contaminated aerosols spread over the whole surgical room and contaminate the theatre and all personnel.

  12. A Prospective Randomized Study Comparing Mini-surgical Percutaneous Dilatational Tracheostomy With Surgical and Classical Percutaneous Tracheostomy

    Science.gov (United States)

    Hashemian, Seyed Mohammad-Reza; Digaleh, Hadi

    2015-01-01

    Abstract Although percutaneous dilatational tracheostomy (PDT) is more accessible and less time-demanding compared with surgical tracheostomy (ST), it has its own limitations. We introduced a modified PDT technique and brought some surgical knowledge to the bedside to overcome some standard percutaneous dilatational tracheostomy relative contraindications. PDT uses a blind route of tracheal access that usually requires perioperational imaging guidance to protect accidental injuries. Moreover, there are contraindications in certain cases, limiting widespread PDT application. Different PDT modifications and devices have been represented to address the problem; however, these approaches are not generally popular among professionals due to limited accessibility and/or other reasons. We prospectively analyzed the double-blinded trial, patient and nurse head evaluating the complications, and collected data from 360 patients who underwent PDT, ST, or our modified mini-surgical PDT (msPDT, Hashemian method). These patients were divided into 2 groups—contraindicated to PDT—and randomization was done for msPDT or PDT in PDT-indicated group and msPDT or ST for PDT-contraindicated patients. The cases were compared in terms of pre and postoperational complications. Data analysis demonstrated that the mean value of procedural time was significantly lower in the msPDT group, either compared with the standard PDT or the ST group. Paratracheal insertion, intraprocedural hypoxemia, and bleeding were also significantly lower in the msPDT group compared with the standard PDT group. Other complications were not significantly different between msPDT and ST patients. The introduced msPDT represented a semiopen incision, other than blinded PDT route of tracheal access that allowed proceduralist to withdraw bronchoscopy and reduced the total time of procedure. Interestingly, the most important improvement was performing msPDT on PDT-contraindicated patients with the complication rate

  13. Development of a tool for evaluating multimedia for surgical education.

    Science.gov (United States)

    Coughlan, Jane; Morar, Sonali S

    2008-09-01

    Educational multimedia has been designed to provide surgical trainees with expert operative information outside of the operating theater. The effectiveness of multimedia (e.g., CD-ROMs) for learning has been a common research topic since the 1990s. To date, however, little discussion has taken place on the mechanisms to evaluate the quality of multimedia-driven teaching. This may be because of a lack of research into the development of appropriate tools for evaluating multimedia, especially for surgical education. This paper reports on a small-scale pilot and exploratory study (n = 12) that developed a tool for surgical multimedia evaluation. The validity of the developed tool was established through adaptation of an existing tool, which was reviewed using experts in surgery, usability, and education. The reliability of the developed tool was tested with surgical trainees who used it to assess a multimedia CD-ROM created for teaching basic surgical skills. The findings contribute to an understanding of surgical trainees' experience of using educational multimedia, in terms of characteristics of the learning material for interface design and content and the process of developing evaluation tools, in terms of inclusion of appropriate assessment criteria. The increasing use of multimedia in medical education necessitates the development of standardized tools for determining the quality of teaching and learning. Little research exists into the development of such tools and so the present work stimulates discussion on how to evaluate surgical training.

  14. An electronic portfolio for quantitative assessment of surgical skills in undergraduate medical education.

    Science.gov (United States)

    Sánchez Gómez, Serafín; Ostos, Elisa María Cabot; Solano, Juan Manuel Maza; Salado, Tomás Francisco Herrero

    2013-05-06

    We evaluated a newly designed electronic portfolio (e-Portfolio) that provided quantitative evaluation of surgical skills. Medical students at the University of Seville used the e-Portfolio on a voluntary basis for evaluation of their performance in undergraduate surgical subjects. Our new web-based e-Portfolio was designed to evaluate surgical practical knowledge and skills targets. Students recorded each activity on a form, attached evidence, and added their reflections. Students self-assessed their practical knowledge using qualitative criteria (yes/no), and graded their skills according to complexity (basic/advanced) and participation (observer/assistant/independent). A numerical value was assigned to each activity, and the values of all activities were summated to obtain the total score. The application automatically displayed quantitative feedback. We performed qualitative evaluation of the perceived usefulness of the e-Portfolio and quantitative evaluation of the targets achieved. Thirty-seven of 112 students (33%) used the e-Portfolio, of which 87% reported that they understood the methodology of the portfolio. All students reported an improved understanding of their learning objectives resulting from the numerical visualization of progress, all students reported that the quantitative feedback encouraged their learning, and 79% of students felt that their teachers were more available because they were using the e-Portfolio. Only 51.3% of students reported that the reflective aspects of learning were useful. Individual students achieved a maximum of 65% of the total targets and 87% of the skills targets. The mean total score was 345 ± 38 points. For basic skills, 92% of students achieved the maximum score for participation as an independent operator, and all achieved the maximum scores for participation as an observer and assistant. For complex skills, 62% of students achieved the maximum score for participation as an independent operator, and 98% achieved

  15. Disc degeneration: current surgical options

    Directory of Open Access Journals (Sweden)

    C Schizas

    2010-10-01

    Full Text Available Chronic low back pain attributed to lumbar disc degeneration poses a serious challenge to physicians. Surgery may be indicated in selected cases following failure of appropriate conservative treatment. For decades, the only surgical option has been spinal fusion, but its results have been inconsistent. Some prospective trials show superiority over usual conservative measures while others fail to demonstrate its advantages. In an effort to improve results of fusion and to decrease the incidence of adjacent segment degeneration, total disc replacement techniques have been introduced and studied extensively. Short-term results have shown superiority over some fusion techniques. Mid-term results however tend to show that this approach yields results equivalent to those of spinal fusion. Nucleus replacement has gained some popularity initially, but evidence on its efficacy is scarce. Dynamic stabilisation, a technique involving less rigid implants than in spinal fusion and performed without the need for bone grafting, represents another surgical option. Evidence again is lacking on its superiority over other surgical strategies and conservative measures. Insertion of interspinous devices posteriorly, aiming at redistributing loads and relieving pain, has been used as an adjunct to disc removal surgery for disc herniation. To date however, there is no clear evidence on their efficacy. Minimally invasive intradiscal thermocoagulation techniques have also been tried, but evidence of their effectiveness is questioned. Surgery using novel biological solutions may be the future of discogenic pain treatment. Collaboration between clinicians and basic scientists in this multidisciplinary field will undoubtedly shape the future of treating symptomatic disc degeneration.

  16. Self-Managing Postoperative Pain with the Use of a Novel, Interactive Device: A Proof of Concept Study

    Directory of Open Access Journals (Sweden)

    Luke Mordecai

    2016-01-01

    Full Text Available Background. Pain is commonly experienced following surgical procedures. Suboptimal management is multifactorial. Objectives. The primary objective was to assess whether patients used a device (Navimed to self-report pain over and above a normal baseline of observations. Secondary outcome measures included comparison of pain scores and patient use of and feedback on the device. Methods. In a prospective randomized controlled trial, elective gynaecological surgery patients received standard postoperative pain care or standard care plus the Navimed, which allowed them to self-report pain and offered interactive self-help options. Results. 52 female patients, 26 in each of device and standard groups, did not differ in the frequency of nurse-documented pain scores or mean pain scores provided to nurses. The device group additionally reported pain on the device (means 18.50 versus 11.90 pain ratings per day, t(32=2.75, p<0.001 that was significantly worse than reported to nurses but retrospectively rated significantly less anxiety. 80% of patients found the device useful. Discussion and Conclusion. This study demonstrates that patients used the Navimed to report pain and to help manage it. Further work is required to investigate the difference in pain scores reported and to develop more sophisticated software.

  17. 77 FR 75173 - Comprehensive Assessment of the Process for the Review of Device Submissions; Request for Comments

    Science.gov (United States)

    2012-12-19

    ..., ``Independent Assessment of Review Process Management'', of the commitment letter entitled ``MDUFA Performance Goals and Procedures'' \\1\\ (MDUFA III Commitment Letter). The assessment will be conducted by an... performance commitments relating to the Medical Device User Fee Amendments of 2012 (MDUFA III), which...

  18. Using Mobile Devices and the Adobe Connect Web Conferencing Tool in the Assessment of EFL Student Teacher Performance

    Science.gov (United States)

    Bolona Lopez, Maria del Carmen; Ortiz, Margarita Elizabeth; Allen, Christopher

    2015-01-01

    This paper describes a project to use mobile devices and video conferencing technology in the assessment of student English as a Foreign Language (EFL) teacher performance on teaching practice in Ecuador. With the increasing availability of mobile devices with video recording facilities, it has become easier for trainers to capture teacher…

  19. British Military surgical key performance indicators: time for an update?

    Science.gov (United States)

    Marsden, Max Er; Sharrock, A E; Hansen, C L; Newton, N J; Bowley, D M; Midwinter, M

    2016-10-01

    Key performance indicators (KPIs) are metrics that compare actual care against an ideal structure, process or outcome standard. KPIs designed to assess performance in deployed military surgical facilities have previously been published. This study aimed to review the overall performance of surgical trauma care for casualties treated at Role 3 Camp Bastion, Medical Treatment Facility, Afghanistan, in light of the existing Defence Medical Services (DMS) KPIs. The secondary aims were to assess the utility of the surgical KPIs and make recommendations for future surgical trauma care review. Data on 22 surgical parameters were prospectively collected for 150 injured patients who had primary surgery at Camp Bastion between 1 May 2013 and 20 August 2013. Additional information for these patients was obtained using the Joint Theatre Trauma Register. The authors assessed data recording, applicability and compliance with the KPIs. Median data recording was 100% (IQR 98%-100%), median applicability was 56% (IQR 10%-99%) and median compliance was 78% (IQR 58%-93%). One KPI was not applicable to any patient in our population. Eleven KPIs achieved >80% compliance, five KPIs had 80%-60% compliance and five KPIs had performance of the surgical aspect of military trauma care in 2013. The KPIs highlight areas for improvement in service delivery. Individual KPI development should be driven by evidence and reflect advances in practice and knowledge. A method of stakeholder consultation, and sequential refinement following evidence review, may be the right process to develop the future set of DMS KPIs. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. Assessment and statistics of surgically induced astigmatism.

    Science.gov (United States)

    Naeser, Kristian

    2008-05-01

    The aim of the thesis was to develop methods for assessment of surgically induced astigmatism (SIA) in individual eyes, and in groups of eyes. The thesis is based on 12 peer-reviewed publications, published over a period of 16 years. In these publications older and contemporary literature was reviewed(1). A new method (the polar system) for analysis of SIA was developed. Multivariate statistical analysis of refractive data was described(2-4). Clinical validation studies were performed. The description of a cylinder surface with polar values and differential geometry was compared. The main results were: refractive data in the form of sphere, cylinder and axis may define an individual patient or data set, but are unsuited for mathematical and statistical analyses(1). The polar value system converts net astigmatisms to orthonormal components in dioptric space. A polar value is the difference in meridional power between two orthogonal meridians(5,6). Any pair of polar values, separated by an arch of 45 degrees, characterizes a net astigmatism completely(7). The two polar values represent the net curvital and net torsional power over the chosen meridian(8). The spherical component is described by the spherical equivalent power. Several clinical studies demonstrated the efficiency of multivariate statistical analysis of refractive data(4,9-11). Polar values and formal differential geometry describe astigmatic surfaces with similar concepts and mathematical functions(8). Other contemporary methods, such as Long's power matrix, Holladay's and Alpins' methods, Zernike(12) and Fourier analyses(8), are correlated to the polar value system. In conclusion, analysis of SIA should be performed with polar values or other contemporary component systems. The study was supported by Statens Sundhedsvidenskabeligt Forskningsråd, Cykelhandler P. Th. Rasmussen og Hustrus Mindelegat, Hotelejer Carl Larsen og Hustru Nicoline Larsens Mindelegat, Landsforeningen til Vaern om Synet

  1. Clinical assessment of the accuracy of blood glucose measurement devices.

    Science.gov (United States)

    Pfützner, Andreas; Mitri, Michael; Musholt, Petra B; Sachsenheimer, Daniela; Borchert, Marcus; Yap, Andrew; Forst, Thomas

    2012-04-01

    Blood glucose meters for patient self-measurement need to comply with the accuracy standards of the ISO 15197 guideline. We investigated the accuracy of the two new blood glucose meters BG*Star and iBG*Star (Sanofi-Aventis) in comparison to four other competitive devices (Accu-Chek Aviva, Roche Diagnostics; FreeStyle Freedom Lite, Abbott Medisense; Contour, Bayer; OneTouch Ultra 2, Lifescan) at different blood glucose ranges in a clinical setting with healthy subjects and patients with type 1 and type 2 diabetes. BGStar and iBGStar are employ dynamic electrochemistry, which is supposed to result in highly accurate results. The study was performed on 106 participants (53 female, 53 male, age (mean ± SD): 46 ± 16 years, type 1: 32 patients, type 2: 34 patients, and 40 healthy subjects). Two devices from each type and strips from two different production lots were used for glucose assessment (∼200 readings/meter). Spontaneous glucose assessments and glucose or insulin interventions under medical supervision were applied to perform measurements in the different glucose ranges in accordance with the ISO 15197 requirements. Sample values 400 mg/dL were prepared by laboratory manipulations. The YSI glucose analyzer (glucose oxidase method) served as the standard reference method which may be considered to be a limitation in light of glucose hexokinase-based meters. For all devices, there was a very close correlation between the glucose results compared to the YSI reference method results. The correlation coefficients were r = 0.995 for BGStar and r = 0.992 for iBGStar (Aviva: 0.995, Freedom Lite: 0.990, Contour: 0.993, Ultra 2: 0.990). Error-grid analysis according to Parkes and Clarke revealed both 100% of the readings to be within the clinically acceptable areas (Clarke: A + B with BG*Star (100 + 0), Aviva (97 + 3), and Contour (97 + 3); and 99.5% with iBG*Star (97.5 + 2), Freedom Lite (98 + 1.5), and Ultra 2 (97.5 + 2

  2. Intraoperative bronchoscopic visualization of left ventricular assist device thrombus.

    Science.gov (United States)

    Yost, Gardner; Bhat, Geetha; Modi, Sejal; Pappas, Pat; Tatooles, Antone

    2016-07-01

    Despite advancements in left ventricular assist device (LVAD) design and clinical management, device thrombosis remains a pertinent complication. Limited imaging makes precise visualization of clot location and shape very challenging. We report the usage of videobronchoscopic exploration of explanted LVADs for direct visualization of clot in two patients. This technique is a rapid and inexpensive means of improving our understanding of LVAD clot formation and may be useful in surgical exploration of inflow and outflow tracts during LVAD exchange. © The Author(s) 2015.

  3. Determining the sample size required to establish whether a medical device is non-inferior to an external benchmark.

    Science.gov (United States)

    Sayers, Adrian; Crowther, Michael J; Judge, Andrew; Whitehouse, Michael R; Blom, Ashley W

    2017-08-28

    The use of benchmarks to assess the performance of implants such as those used in arthroplasty surgery is a widespread practice. It provides surgeons, patients and regulatory authorities with the reassurance that implants used are safe and effective. However, it is not currently clear how or how many implants should be statistically compared with a benchmark to assess whether or not that implant is superior, equivalent, non-inferior or inferior to the performance benchmark of interest.We aim to describe the methods and sample size required to conduct a one-sample non-inferiority study of a medical device for the purposes of benchmarking. Simulation study. Simulation study of a national register of medical devices. We simulated data, with and without a non-informative competing risk, to represent an arthroplasty population and describe three methods of analysis (z-test, 1-Kaplan-Meier and competing risks) commonly used in surgical research. We evaluate the performance of each method using power, bias, root-mean-square error, coverage and CI width. 1-Kaplan-Meier provides an unbiased estimate of implant net failure, which can be used to assess if a surgical device is non-inferior to an external benchmark. Small non-inferiority margins require significantly more individuals to be at risk compared with current benchmarking standards. A non-inferiority testing paradigm provides a useful framework for determining if an implant meets the required performance defined by an external benchmark. Current contemporary benchmarking standards have limited power to detect non-inferiority, and substantially larger samples sizes, in excess of 3200 procedures, are required to achieve a power greater than 60%. It is clear when benchmarking implant performance, net failure estimated using 1-KM is preferential to crude failure estimated by competing risk models. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No

  4. Wrong-Site Surgery, Retained Surgical Items, and Surgical Fires : A Systematic Review of Surgical Never Events.

    Science.gov (United States)

    Hempel, Susanne; Maggard-Gibbons, Melinda; Nguyen, David K; Dawes, Aaron J; Miake-Lye, Isomi; Beroes, Jessica M; Booth, Marika J; Miles, Jeremy N V; Shanman, Roberta; Shekelle, Paul G

    2015-08-01

    Serious, preventable surgical events, termed never events, continue to occur despite considerable patient safety efforts. To examine the incidence and root causes of and interventions to prevent wrong-site surgery, retained surgical items, and surgical fires in the era after the implementation of the Universal Protocol in 2004. We searched 9 electronic databases for entries from 2004 through June 30, 2014, screened references, and consulted experts. Two independent reviewers identified relevant publications in June 2014. One reviewer used a standardized form to extract data and a second reviewer checked the data. Strength of evidence was established by the review team. Data extraction was completed in January 2015. Incidence of wrong-site surgery, retained surgical items, and surgical fires. We found 138 empirical studies that met our inclusion criteria. Incidence estimates for wrong-site surgery in US settings varied by data source and procedure (median estimate, 0.09 events per 10,000 surgical procedures). The median estimate for retained surgical items was 1.32 events per 10,000 procedures, but estimates varied by item and procedure. The per-procedure surgical fire incidence is unknown. A frequently reported root cause was inadequate communication. Methodologic challenges associated with investigating changes in rare events limit the conclusions of 78 intervention evaluations. Limited evidence supported the Universal Protocol (5 studies), education (4 studies), and team training (4 studies) interventions to prevent wrong-site surgery. Limited evidence exists to prevent retained surgical items by using data-matrix-coded sponge-counting systems (5 pertinent studies). Evidence for preventing surgical fires was insufficient, and intervention effects were not estimable. Current estimates for wrong-site surgery and retained surgical items are 1 event per 100,000 and 1 event per 10,000 procedures, respectively, but the precision is uncertain, and the per

  5. Local antimicrobial administration for prophylaxis of surgical site infections.

    Science.gov (United States)

    Huiras, Paul; Logan, Jill K; Papadopoulos, Stella; Whitney, Dana

    2012-11-01

    Despite a lack of consensus guidelines, local antibiotic administration for prophylaxis of surgical site infections is used during many surgical procedures. The rationale behind this practice is to provide high antibiotic concentrations at the site of surgery while minimizing systemic exposure and adverse effects. Local antibiotic administration for surgical site prophylaxis has inherent limitations in that antibiotics are applied after the incision is made, rather than the current standard for surgical site prophylaxis that recommends providing adequate antibiotic concentrations at the site before the incision. The efficacy and safety of local application of antibiotics for surgical site prophylaxis have been assessed in different types of surgery with a variety of antibiotic agents and methods of application. We identified 22 prospective, randomized, controlled trials that evaluated local application of antibiotics for surgical site prophylaxis. These trials were subsequently divided and analyzed based on the type of surgical procedure: dermatologic, orthopedic, abdominal, colorectal, and cardiothoracic. Methods of local application analyzed included irrigations, powders, ointments, pastes, beads, sponges, and fleeces. Overall, there is a significant lack of level I evidence supporting this practice for any of the surgical genres evaluated. In addition, the literature spans several decades, and changes in surgical procedures, systemic antibiotic prophylaxis, and microbial flora make conclusions difficult to determine. Based on available data, the efficacy of local antibiotic administration for the prophylaxis of surgical site infections remains uncertain, and recommendations supporting this practice for surgical site prophylaxis cannot be made. © 2012 Pharmacotherapy Publications, Inc.

  6. New devices and technology in interventional cardiology.

    Science.gov (United States)

    Tobis, Jonathan Marvin; Abudayyeh, Islam

    2015-01-01

    There have been substantial improvements made in the tools and techniques used since the advent of percutaneous coronary intervention. What was primarily developed as a treatment of coronary artery disease is now used to address a variety of structural heart disease problems. The outcomes have been remarkably successful with relatively low complication rates that rival the results of open-heart surgery. This article will review some of the new devices available for management of structural cardiac conditions including congenital defects and acquired valvular abnormalities. Transcatheter treatment offers advantages over surgical intervention in recovery time, improved patient satisfaction, lower procedural risk, and avoidance of cardio-pulmonary bypass especially in high-risk patients. We will discuss different medical conditions and introduce the devices used to treat these conditions. Each device or technique has benefits and risks, and familiarity with the devices along with patient selection will best optimize the outcome. Copyright © 2014 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  7. Experimental Investigation of Ventilation Efficiency in a Dentistry Surgical Room

    Directory of Open Access Journals (Sweden)

    Oladokun Majeed Olaide

    2016-01-01

    Full Text Available As a response to the need to provide an acceptable thermal comfort and air quality in indoor environments, various ventilation performance indicators were developed over the years. These metrics are mainly geared towards air distribution, heat and pollutant removals. Evidence exists of influencing factors on these indicators as centered on ventilation design and operations. Unlike other indoor environments, health care environment requires better performance of ventilation system to prevent an incidence of nosocomial and other hospital acquired illnesses. This study investigates, using in-situ experiments, the ventilation efficiency in a dentistry surgical room. Thermal and hygric parameters were monitored on the air terminal devices and occupied zone over a period of one week covering both occupied and unoccupied hours. The resulting time-series parameters were used to evaluate the room’s ventilation effectiveness. Also, the obtained parameters were benchmarked against ASHRAE 170 (2013 and MS1525 (2014 requirements for ventilation in health care environment and building energy efficiency respectively. The results show that the mean daily operative conditions failed to satisfy the provisions of both standards. Regarding effectiveness, the findings reveal that the surgical room ventilation is ineffective with ventilation efficiency values ranging between 0 and 0.5 indicating air distribution short-circuiting. These results suggest further investigations, through numerical simulation, on the effect of this short-circuiting on thermal comfort, infection risk assessments and possible design improvements, an endeavour that forms our next line of research inquiries.

  8. Molecular cloning of Brevundimonas diminuta for efficacy assessment of reverse osmosis devices.

    Science.gov (United States)

    Donofrio, Robert; Saha, Ratul; Bestervelt, Lori; Bagley, Susan

    2012-06-01

    Brevundimonas diminuta is the test organism specified in the United States Environmental Protection Agency's (USEPA) reverse osmosis (RO) treatment device verification protocol. As non-selective growth medium is employed, enumeration of B. diminuta may be impaired due to interference by indigenous heterotrophic bacteria. Thus the microbial removal capability of the filtration system may be incorrectly assessed. As these treatment devices are used in emergency situations, the health of the public could be compromised. The objective of this study was to develop selective approaches for enumerating viable B. diminuta in test water. Two molecular approaches were investigated: expression of a kanamycin resistance gene and expression of a fluorescent protein gene. The USEPA protocol specifies a 0.3 μm cell size, so the expression of the selective markers were assessed following growth on media designed to induce this small cell diameter. The kan(R) strain was demonstrated to be equivalent to the wild type in cell dimension and survival following exposure to the test water. The kan(R) strain showed equivalent performance to the wild type in the RO protocol indicating that it is a viable alternative surrogate. By utilizing this strain, a more accurate validation of the RO system can be achieved.

  9. Protein adsorption on low temperature alpha alumina films for surgical instruments

    Energy Technology Data Exchange (ETDEWEB)

    Cloud, A.N., E-mail: acloud@uark.ed [University of Arkansas, Fayetteville, AR 72701 (United States); Kumar, S. [Ian Wark Research Institute, University of South Australia, Mawson Lakes, Adelaide, SA 5095 (Australia); Kavdia, M.; Abu-Safe, H.H.; Gordon, M.H. [University of Arkansas, Fayetteville, AR 72701 (United States)

    2009-08-31

    Bulk alumina has been shown to exhibit reduced protein adsorption, a property that can be exploited for developing alumina-coated surgical instruments and devices. Alpha alumina thin films were deposited on surgical stainless steel substrates to investigate the adsorption of a model protein (BSA, bovine serum albumin). The films were deposited at 480 {sup o}C by AC inverted cylindrical magnetron sputtering. Films were obtained at 6 kW and 50% oxygen partial pressure by volume. The presence of alpha-phase alumina has been shown by transmission electron microscopy. Results indicate that there was a 50% reduction in protein adsorption for samples with the alumina coating compared to those with no coating.

  10. Dressings and topical agents for surgical wounds healing by secondary intention

    NARCIS (Netherlands)

    Vermeulen, H.; Ubbink, D.; Goossens, A.; de Vos, R.; Legemate, D.

    2004-01-01

    BACKGROUND: Many different wound dressings and topical applications are used to cover surgical wounds healing by secondary intention. It is not known whether these dressings heal wounds at different rates. OBJECTIVES: To assess the effectiveness of dressings and topical agents on surgical wounds

  11. Surgical Instrument Sets for Special Operations Expeditionary Surgical Teams.

    Science.gov (United States)

    Hale, Diane F; Sexton, Justin C; Benavides, Linda C; Benavides, Jerry M; Lundy, Jonathan B

    The deployment of surgical assets has been driven by mission demands throughout years of military operations in Iraq and Afghanistan. The transition to the highly expeditious Golden Hour Offset Surgical Transport Team (GHOST- T) now offers highly mobile surgical assets in nontraditional operating rooms; the content of the surgical instrument sets has also transformed to accommodate this change. The 102nd Forward Surgical Team (FST) was attached to Special Operations assigned to southern Afghanistan from June 2015 to March 2016. The focus was to decrease overall size and weight of FST instrument sets without decreasing surgical capability of the GHOST-T. Each instrument set was evaluated and modified to include essential instruments to perform damage control surgery. The overall number of main instrument sets was decreased from eight to four; simplified augmentation sets have been added, which expand the capabilities of any main set. The overall size was decreased by 40% and overall weight decreased by 58%. The cardiothoracic, thoracotomy, and emergency thoracotomy trays were condensed to thoracic set. The orthopedic and amputation sets were replaced with an augmentation set of a prepackaged orthopedic external fixator set). An augmentation set to the major or minor basic sets, specifically for vascular injuries, was created. Through the reorganization of conventional FST surgical instrument sets to maintain damage control capabilities and mobility, the 102nd GHOST-T reduced surgical equipment volume and weight, providing a lesson learned for future surgical teams operating in austere environments. 2017.

  12. Comparison of postoperative surgical site infection after preoperative marking done with non-sterile stationary grade markers versus sterile surgical markers

    International Nuclear Information System (INIS)

    Mir, Z.A.

    2015-01-01

    Objectives: To compare the frequencies of post- operative surgical site infection after preoperative marking done with non-sterile stationary. grade markers versus sterile surgical markers in the same patient. Design: Randomized control trial. Place and Duration of Study: The department of Plastic surgery, Mayo hospital, Lahore from August 2013 to August 2014. Methods: This study was conducted after taking approval from the departmental ethical committee. Forty consecutive patients were included. A sterile surgical marker was used to mark one incision site while an alcohol based stationary grade marker was used to mark another incision site on the same patient. A standard preoperative, intraoperative and postoperative protocol was followed. Cultures were performed on swabs taken from the incision sites and surgical site infection was assessed for 30 days. Results: The study included 40 patients; 17 males and 23 females. The mean age of subjects was 25.32 ± 19.69 years with the minimum age being 2 years and the maximum being 63 years. No growth was seen in cultures taken from all the incision sites after skin preparation in the non sterile stationary grade marker group as well as the sterile surgical grade marker group. Also no surgical site infection appeared during the 30 day postoperative observation period in the non sterile stationary grade marker group as well as the sterile surgical grade marker group. (author)

  13. Evaluation of surgical treatment in mandibular condyle fractures.

    Science.gov (United States)

    Vesnaver, Aleš; Ahčan, Uroš; Rozman, Janez

    2012-12-01

    In the past, fractures of the mandibular condylar process were, as a rule, treated conservatively. At the Department of Maxillofacial and Oral Surgery of the University Medical Centre Ljubljana, Slovenia, our doctrine was changed in 2002 on the basis of preliminary results and reports in the literature, and these fractures were started to be treated surgically by open reduction and internal fixation with miniplates and screws, which led to good results and a shorter rehabilitation period. The goal of this study was to determine the safety and efficiency of surgical treatment, as well as to compare long-term results of surgical and conservative treatment, as objectively as possible. Two groups of patients, which had all sustained a unilateral, extra-articular mandibular condyle fracture, were compared. In the test group, there were 42 surgically treated patients, and in the control group, 20 conservatively treated patients. Clinical parameters and X-ray images were assessed in both groups and compared by the two tailed Student t test, and in case of attributive variables by the χ(2) test. Within the surgically treated group, postoperative and intraoperative complications were noted: temporary facial nerve palsy, development of a parotid salivary fistula, disturbance of auricle sensibility due to injury of the greater auricular nerve, miniplate fracture, as well as intraoperative bleeding, postoperative haematoma formation, infection, reoperation due to fragment malposition and other complications. Postoperative scars were also assessed. Statistically significant differences between the surgically and conservatively treated patients were found when comparing clinical parameters as well as X-ray images, the results being better in the surgically treated group. Complications of surgical treatment were also noted, the most important among them temporary paresis of facial nerve branches, which occurred in 10 patients (24%). Plate fractures occurred in five patients (12

  14. The modern surgeon and competency assessment: are the workplace-based assessments evidence-based?

    Science.gov (United States)

    Torsney, K M; Cocker, D M; Slesser, A A P

    2015-03-01

    The assessment of higher surgical training has changed in the last decade or two, with a greater emphasis on work-based assessments (WBAs) to prove competency. The aim of this study was to determine the evidence underpinning the use and number of WBAs in surgical training. In July 2013, a systematic electronic literature review was undertaken using PubMed (Medline), Embase, Google Scholar and the Cochrane library. A total of 27 studies met the inclusion criteria of which 25 were observational studies and only five assessed WBAs in a surgical setting. Validity and feasibility in surgical training were assessed in two studies, respectively, with the results suggesting that WBAs maybe neither feasible nor valid in surgical training. The number required to achieve reliability in surgical training was demonstrated to be three in two separate studies. The evidence for the reliability, feasibility and validity of WBAs in other non-surgical fields was conflicting. There is a paucity of evidence supporting the use of WBAs as a tool to determine competency in surgical training, and as such, they should only have a limited role in training until more evidence is available. There appears to be no justification or evidence underpinning the use of a specific number of WBAs to determine surgical competency.

  15. Surgical orthodontics.

    Science.gov (United States)

    Strohl, Alexis M; Vitkus, Lauren

    2017-08-01

    The article reviews some commonly used orthodontic treatments as well as new strategies to assist in the correction of malocclusion. Many techniques are used in conjunction with surgical intervention and are a necessary compliment to orthognathic surgery. Basic knowledge of these practices will aid in the surgeon's ability to adequately treat the patient. Many orthodontists and surgeons are eliminating presurgical orthodontics to adopt a strategy of 'surgery first' orthodontics in orthognathic surgery. This has the benefit of immediate improvement in facial aesthetics and shorter treatment times. The advent of virtual surgical planning has helped facilitate the development of this new paradigm by making surgical planning faster and easier. Furthermore, using intraoperative surgical navigation is improving overall precision and outcomes. A variety of surgical and nonsurgical treatments may be employed in the treatment of malocclusion. It is important to be familiar with all options available and tailor the patient's treatment plan accordingly. Surgery-first orthodontics, intraoperative surgical navigation, virtual surgical planning, and 3D printing are evolving new techniques that are producing shorter treatment times and subsequently improving patient satisfaction without sacrificing long-term stability.

  16. Intrasurgical Human Retinal Imaging With Manual Instrument Tracking Using a Microscope-Integrated Spectral-Domain Optical Coherence Tomography Device.

    Science.gov (United States)

    Hahn, Paul; Carrasco-Zevallos, Oscar; Cunefare, David; Migacz, Justin; Farsiu, Sina; Izatt, Joseph A; Toth, Cynthia A

    2015-07-01

    To characterize the first in-human intraoperative imaging using a custom prototype spectral-domain microscope-integrated optical coherence tomography (MIOCT) device during vitreoretinal surgery with instruments in the eye. Under institutional review board approval for a prospective intraoperative study, MIOCT images were obtained at surgical pauses with instruments held static in the vitreous cavity and then concurrently with surgical maneuvers. Postoperatively, MIOCT images obtained at surgical pauses were compared with images obtained with a high-resolution handheld spectral-domain OCT (HHOCT) system with objective endpoints, including acquisition of images acceptable for analysis and identification of predefined macular morphologic or pathologic features. Human MIOCT images were successfully obtained before incision and during pauses in surgical maneuvers. MIOCT imaging confirmed preoperative diagnoses, such as epiretinal membrane, full-thickness macular hole, and vitreomacular traction and demonstrated successful achievement of surgical goals. MIOCT and HHOCT images obtained at surgical pauses in two cohorts of five patients were comparable with greater than or equal to 80% correlation in 80% of patients. Real-time video-imaging concurrent with surgical manipulations enabled, for the first time using this device, visualization of dynamic instrument-retina interaction with targeted OCT tracking. MIOCT is successful for imaging at surgical pauses and for real-time image guidance with implementation of targeted OCT tracking. Even faster acquisition speeds are currently being developed with incorporation of a swept-source MIOCT engine. Further refinements and investigations will be directed toward continued integration for real-time volumetric imaging of surgical maneuvers. Ongoing development of seamless MIOCT systems will likely transform surgical visualization, approaches, and decision-making.

  17. Systematic Review of Pain assessment scales in newborns under maxillofacial surgery Admitted to the surgical ward

    Directory of Open Access Journals (Sweden)

    Shapour Yaripoor

    2016-10-01

    Full Text Available Having standard tools for measuring pain in infants is essential. The aim of this study is to review the scale of pain in newborns under maxillofacial surgery Admitted to the surgical ward. Integrative review study of articles published from 2000 to 2015, carried out in the following databases: Scopus, PubMed, CINAHL, LILACS, Cochrane, medscape and google scholar. The sample consisted of 17 articles. MeSH headings searched included pain measurement, pain scale, newborn pain, infant pain scale, maxillofacial surgery and pain perception. 16 neonatal pain assessment tools were found. Of the 232 original articles, 17 review articles in the field of pain assessment tools in infant under maxillofacial surgery who had inclusion criteria were selected. The most studied was the Premature Infant Pain Profile (PIPP, The CRIES and the Neonatal Infant Pain Scale (NIPS. Infant pain assessment is not universally standardized. Practitioners may assess pain; however, they may not consistently use the same criteria to do so. The use of Neonatal Facial Coding System, the Neonatal Infant Pain Scale and the Premature Infant Pain Profile Can accurately show the amount of pain in newborns.

  18. Focused review on transthoracic echocardiographic assessment of patients with continuous axial left ventricular assist devices.

    Science.gov (United States)

    Topilsky, Yan; Maltais, Simon; Oh, Jae K; Atchison, Fawn W; Perrault, Louis P; Carrier, Michel; Park, Soon J

    2011-02-08

    Left ventricular assist devices (LVADs) are systems for mechanical support for patients with end-stage heart failure. Preoperative, postoperative and comprehensive followup with transthoracic echocardiography has a major role in LVAD patient management. In this paper, we will present briefly the hemodynamics of axial-flow LVAD, the rationale, and available data for a complete and organized echocardiographic assessment in these patients including preoperative assessment, postoperative and long-term evaluation.

  19. A New Method for Treatment of Lymphedema of Limbs: Standardized Manual Massage with a New Device Linforoll in Conservative and Surgical Therapy Protocols.

    Science.gov (United States)

    Olszewski, Waldemar L; Zaleska, Marzanna; Michelin, Sandro

    2016-12-01

    Edema fluid in lymphedematous limbs should be evacuated to sites where it can be absorbed. It should be moved either to the hypogastrium or arm/scapular regions along tissue channels or implanted silicon channels or through lymphovenous anastomoses. For that purpose, the manual lymphatic drainage of limb is an effective method. Standardization of manual massage applied force and timing becomes necessary. A device with known pressing area and continuously showing the applied force while moving it toward the root of the limb is needed. Moreover, force could be adjusted to the stiffness of the massaged tissues that varies at different levels of the limb. Results from such a device would be repeatable and reproducible by others. In this study we present data on tissue fluid hydromechanics obtained from 20 patients with obstructive limb lymphedema during massage with a massaging roller called Linforoll. Linforoll is composed of a hand piece with roller and pressure sensor connected wireless to the computer displaying the pressure curve of the applied force. Electron microscopy studies for checking eventual tissue changes were done. Linforoll provides the possibilities of: 1) regulating the applied force according to the hydromechanic conditions of the massaged tissues; 2) standardization of massage repeatable in the same patient; 3) decrease of limb volume; 4) evident increase in tissue elasticity; 5) application as a driving force for fluid flow along the surgically implanted tubing and vessels running to the lymphovenous shunts.

  20. Endometrial cancer treated with levonorgestrel-releasing intrauterine device for almost three years in an elderly woman with comorbidity

    DEFF Research Database (Denmark)

    Andreasen, Lisbeth Anita; Antonsen, Sofie Leisby; Settnes, Annette

    2016-01-01

    but with a minimum of symptoms and side effects. At the final examination there were no signs of extra uterine disease. The levonorgestrel-releasing intrauterine device may be an acceptable alternative to surgery in severely comorbid patients, or if the patient refuses surgical treatment. © 2016, Springer......In this case report we describe the treatment of a 95-year-old woman with endometrioid adenocarcinoma. She suffered from cardiovascular comorbidity and did not want surgical treatment. Instead a levonorgestrel-releasing intrauterine device (Mirena) was inserted. She had progression of the tumor...

  1. Development of a Detailed Volumetric Finite Element Model of the Spine to Simulate Surgical Correction of Spinal Deformities

    Directory of Open Access Journals (Sweden)

    Mark Driscoll

    2013-01-01

    Full Text Available A large spectrum of medical devices exists; it aims to correct deformities associated with spinal disorders. The development of a detailed volumetric finite element model of the osteoligamentous spine would serve as a valuable tool to assess, compare, and optimize spinal devices. Thus the purpose of the study was to develop and initiate validation of a detailed osteoligamentous finite element model of the spine with simulated correction from spinal instrumentation. A finite element of the spine from T1 to L5 was developed using properties and geometry from the published literature and patient data. Spinal instrumentation, consisting of segmental translation of a scoliotic spine, was emulated. Postoperative patient and relevant published data of intervertebral disc stress, screw/vertebra pullout forces, and spinal profiles was used to evaluate the models validity. Intervertebral disc and vertebral reaction stresses respected published in vivo, ex vivo, and in silico values. Screw/vertebra reaction forces agreed with accepted pullout threshold values. Cobb angle measurements of spinal deformity following simulated surgical instrumentation corroborated with patient data. This computational biomechanical analysis validated a detailed volumetric spine model. Future studies seek to exploit the model to explore the performance of corrective spinal devices.

  2. A Comparison and Calibration of a Wrist-Worn Blood Pressure Monitor for Patient Management: Assessing the Reliability of Innovative Blood Pressure Devices

    Science.gov (United States)

    Melville, Sarah; Teskey, Robert; Philip, Shona; Simpson, Jeremy A; Lutchmedial, Sohrab

    2018-01-01

    Background Clinical guidelines recommend monitoring of blood pressure at home using an automatic blood pressure device for the management of hypertension. Devices are not often calibrated against direct blood pressure measures, leaving health care providers and patients with less reliable information than is possible with current technology. Rigorous assessments of medical devices are necessary for establishing clinical utility. Objective The purpose of our study was 2-fold: (1) to assess the validity and perform iterative calibration of indirect blood pressure measurements by a noninvasive wrist cuff blood pressure device in direct comparison with simultaneously recorded peripheral and central intra-arterial blood pressure measurements and (2) to assess the validity of the measurements thereafter of the noninvasive wrist cuff blood pressure device in comparison with measurements by a noninvasive upper arm blood pressure device to the Canadian hypertension guidelines. Methods The cloud-based blood pressure algorithms for an oscillometric wrist cuff device were iteratively calibrated to direct pressure measures in 20 consented patient participants. We then assessed measurement validity of the device, using Bland-Altman analysis during routine cardiovascular catheterization. Results The precalibrated absolute mean difference between direct intra-arterial to wrist cuff pressure measurements were 10.8 (SD 9.7) for systolic and 16.1 (SD 6.3) for diastolic. The postcalibrated absolute mean difference was 7.2 (SD 5.1) for systolic and 4.3 (SD 3.3) for diastolic pressures. This is an improvement in accuracy of 33% systolic and 73% diastolic with a 48% reduction in the variability for both measures. Furthermore, the wrist cuff device demonstrated similar sensitivity in measuring high blood pressure compared with the direct intra-arterial method. The device, when calibrated to direct aortic pressures, demonstrated the potential to reduce a treatment gap in high blood

  3. Surgical treatment analysis of idiopathic esophageal achalasia.

    Science.gov (United States)

    Aquino, José Luis Braga de; Said, Marcelo Manzano; Pereira, Douglas Rizzanti; Amaral, Paula Casals do; Lima, Juliana Carolina Alves; Leandro-Merhi, Vânia Aparecida

    2015-01-01

    Idiopathic esophageal achalasia is an inflammatory disease of unknown origin, characterized by aperistalsis of the esophageal body and failure of the lower esophageal sphincter in response to swallowing, with consequent dysphagia. To demonstrate the results of surgical therapy in these patients, evaluating the occurred local and systemic complications. Were studied retrospectively 32 patients, 22 of whom presented non-advanced stage of the disease (Stage I/II) and 10 with advanced disease (Stage III/IV). All of them had the clinical conditions to be submitted to surgery. The diagnoses were done by clinical, endoscopic, cardiological, radiological and esophageal manometry analysis. Pre-surgical evaluation was done with a questionnaire based on the most predisposing factors in the development of the disease and the surgical indication was based on the stage of the disease. The patients with non-advanced stages were submitted to cardiomyotomy with fundoplication, wherein in the post-surgical early assessment, only one (4,4%) presented pulmonary infection, but had a good outcome. In patients with advanced disease, seven were submitted to esophageal mucosectomy preserving the muscular layer, wherein one patient (14,2%) presented dehiscence of gastric cervical esophagus anastomosis as well as pulmonary infection; all of these complications were resolved with proper specific treatment; the other three patients with advanced stage were submitted to transmediastinal esophagectomy; two of them presented hydropneumothorax with good evolution, and one of them also presented fistula of the cervical esophagogastric anastomosis, but with spontaneous healing after conservative treatment and nutritional support. The two patients with fistula of the cervical anastomosis progressed to stenosis, with good results after endoscopic dilations. In the medium and long term assessment done in 23 patients, all of them reported improvement in life quality, with return to swallowing. The

  4. Surgical versus non-surgical management of abdominal injury.

    Science.gov (United States)

    Oyo-Ita, Angela; Chinnock, Paul; Ikpeme, Ikpeme A

    2015-11-13

    Injury to the abdomen can be blunt or penetrating. Abdominal injury can damage internal organs such as the liver, spleen, kidneys, intestine, and large blood vessels. There are controversies about the best approach to manage abdominal injuries. To assess the effects of surgical and non-surgical interventions in the management of abdominal trauma in a haemodynamically stable and non-peritonitic abdomen. We searched the Cochrane Injuries Group's Specialised Register, The Cochrane Library, Ovid MEDLINE(R), Ovid MEDLINE(R) In-Process & Other Non-Indexed Citations, Ovid MEDLINE(R) Daily and Ovid OLDMEDLINE(R), EMBASE Classic+EMBASE (Ovid), ISI WOS (SCI-EXPANDED, SSCI, CPCI-S & CPSI-SSH), CINAHL Plus (EBSCO), and clinical trials registers, and screened reference lists. We ran the most recent search on 17 September 2015. Randomised controlled trials of surgical interventions and non-surgical interventions involving people with abdominal injury who were haemodynamically stable with no signs of peritonitis. The abdominal injury could be blunt or penetrating. Two review authors independently applied the selection criteria. Data were extracted by two authors using a standard data extraction form, and are reported narratively. Two studies are included, which involved a total of 114 people with penetrating abdominal injuries. Both studies are at moderate risk of bias because the randomisation methods are not fully described, and the original study protocols are no longer available. The studies were undertaken in Finland between 1992 and 2002, by the same two researchers.In one study, 51 people were randomised to surgery or an observation protocol. None of the participants in the study died. Seven people had complications: 5 (18.5%) in the surgical group and 2 (8.3%) in the observation group; the difference was not statistically significant (P = 0.42; Fischer's exact). Among the 27 people who had surgery, 6 (22.2%) surgeries were negative laparotomies, and 15 (55.6%) were non

  5. Transcatheter closure, mini-invasive closure and open-heart surgical repair for treatment of perimembranous ventricular septal defects in children: a protocol for a network meta-analysis.

    Science.gov (United States)

    You, Tao; Yi, Kang; Ding, Zhao-Hong; Hou, Xiao-Dong; Liu, Xing-Guang; Wang, Xin-Kuan; Ge, Long; Tian, Jin-Hui

    2017-06-21

    Both transcatheter device closure and surgical repair are effective treatments with excellent midterm outcomes for perimembranous ventricular septal defects (pmVSDs) in children. The mini-invasive periventricular device occlusion technique has become prevalent in research and application, but evidence is limited for the assessment of transcatheter closure, mini-invasive closure and open-heart surgical repair. This study comprehensively compares the efficacy, safety and costs of transcatheter closure, mini-invasive closure and open-heart surgical repair for treatment of pmVSDs in children using Bayesian network meta-analysis. A systematic search will be performed using Chinese Biomedical Literature Database, China National Knowledge Infrastructure, PubMed, EMBASE.com and the Cochrane Central Register of Controlled Trials to include random controlled trials, prospective or retrospective cohort studies comparing the efficacy, safety and costs of transcatheter closure, mini-invasive closure and open-heart surgical repair. The risk of bias for the included prospective or retrospective cohort studies will be evaluated according to the risk of bias in non-randomised studies of interventions (ROBINS-I). For random controlled trials, we will use risk of bias tool from Cochrane Handbook version 5.1.0. A Bayesian network meta-analysis will be conducted using R-3.3.2 software. Ethical approval and patient consent are not required since this study is a network meta-analysis based on published trials. The results of this network meta-analysis will be submitted to a peer-reviewed journal for publication. CRD42016053352. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  6. Assessment of Selected Parameters of the Automatic Scarification Device as an Example of a Device for Sustainable Forest Management

    Directory of Open Access Journals (Sweden)

    Ryszard Tadeusiewicz

    2017-12-01

    Full Text Available Due to technological progress in forestry, seedlings with covered root systems—especially those grown in container nurseries—have become increasingly important in forest nursery production. One the trees that is most commonly grown this way is the common oak (Quercus robur L.. For an acorn to be sown in a container, it is necessary to remove its upper part during mechanical scarification, and evaluate its sowing suitability. At present, this is mainly done manually and by visual assessment. The low effectiveness of this method of acorn preparation has encouraged a search for unconventional solutions. One of them is the use of an automated device that consists of a computer vision-based module. For economic reasons related to the cost of growing seedlings in container nurseries, it is beneficial to minimize the contribution of unhealthy seeds. The maximum accuracy, which is understood as the number of correct seed diagnoses relative to the total number of seeds being assessed, was adopted as a criterion for choosing a separation threshold. According to the method proposed, the intensity and red components of the images of scarified acorns facilitated the best results in terms of the materials examined during the experiment. On average, a 10% inaccuracy of separation was observed. A secondary outcome of the presented research is an evaluation of the ergonomic parameters of the user interface that is attached to the unit controlling the device when it is running in its autonomous operation mode.

  7. Effective vulnerability assessments for physical security devices, systems, and programs

    International Nuclear Information System (INIS)

    Johnston, R.G.; Garcia, A.R.E.

    2002-01-01

    Full text: The efficacy of devices, systems, and programs used for physical security depend critically on having periodic and effective vulnerability assessments. Effective vulnerability assessments, in turn, require certain conditions and attributes. These include: a proper understanding of their purpose; not confusing vulnerability assessments with other kinds of metrics, analyses, tests, and security exercises; the view that vulnerabilities are inevitable, and that finding them is good news (since they can then be mitigated), not bad news; rejection of findings of no vulnerabilities; avoidance of mere 'compliance mode' rubber stamping; the use of the proper outside, independent, imaginative personnel; psychologically predisposed to finding and demonstrating problems; the absence of conflicts of interest; no unrealistic constraints on the possible attack tools, procedures, personnel, or strategies; efforts to not just find and demonstrate vulnerabilities, but also to suggest possible countermeasures; proper context; input and buy-in from ALL facility security personnel, especially low-level personnel; emphasis on the simplest, most relevant attacks first; no underestimation of potential adversaries; consideration of fault analysis attacks; awareness of Rohrbach's Maxim and Shannon's Maxim. In addition to these factors, we will cover some of the complex issues and problems associated with the design of vulnerability assessments. There will also be suggestions on how to conduct effective vulnerability assessments on a severely limited budget. We will conclude with a discussion of both conventional and unconventional ways of reporting results. (author)

  8. [Theoretical and practical assessment of Lille general practice and pharmacy students' knowledge about use of inhaler devices for asthma control].

    Science.gov (United States)

    Veylon, P; Rochoy, M; Gautier, S; Wallaert, B; Berkhout, C

    2018-04-01

    Asthma is a potentially serious chronic respiratory disease impacting patients quality of life. Satisfactory control requires proper use of inhaled devices. This study assesses general medical residents and pharmacy students knowledge about proper use of inhaled asthma devices. We evaluated knowledge of 43 general practice students and 43 pharmacy students in Lille for three inhaler devices (metered-dose inhaler, Turbuhaler ® and Diskus ® ) during individual interviews. Students were assessed on 8 proper use criterias for each device. General practice and pharmacy students are unfamiliar with proper use of inhaler devices. However, pharmacy students get better average scores than general practice students for all devices included in this study: 6.3/8 respected criterias against 5/8 for metered-dose inhaler; 5.3/8 against 3.2/8 for Turbuhaler ® ; and 6/8 against 4.3/8 for Diskus ® . Pharmacy students more frequently perform a demonstration of proper use to patients when a device is first prescribed or when a prescription is renewed; general practice students more frequently ask patients themselves to perform a demonstration of proper use. Introducing trainings workshops for inhaler devices to pharmacy and general practice students appears appropriate in order to promote therapeutic patient education, to increase asthma control and better patients life quality. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  9. Utility of 3D printed temporal bones in pre-surgical planning for complex BoneBridge cases.

    Science.gov (United States)

    Mukherjee, Payal; Cheng, Kai; Flanagan, Sean; Greenberg, Simon

    2017-08-01

    With the advent of single-sided hearing loss increasingly being treated with cochlear implantation, bone conduction implants are reserved for cases of conductive and mixed hearing loss with greater complexity. The BoneBridge (BB, MED-EL, Innsbruck, Austria) is an active fully implantable device with no attenuation of sound energy through soft tissue. However, the floating mass transducer (FMT) part of the device is very bulky, which limits insertion in complicated ears. In this study, 3D printed temporal bones of patients were used to study its utility in preoperative planning on complicated cases. Computed tomography (CT) scans of 16 ears were used to 3D print their temporal bones. Three otologists graded the use of routine preoperative planning provided by MED-EL and that of operating on the 3D printed bone of the patient. Data were collated to assess the advantage and disadvantage of the technology. There was a statistically significant benefit in using 3D printed temporal bones to plan surgery for difficult cases of BoneBridge surgery compared to the current standard. Surgeons preferred to have the printed bones in theatre to plan their drill sites and make the transition of the planning to the patient's operation more precise. 3D printing is an innovative use of technology in the use of preoperative planning for complex ear surgery. Surgical planning can be done on the patient's own anatomy which may help to decrease operating time, reduce cost, increase surgical precision and thus reduce complications.

  10. The Application of Surgical Navigation in the Treatment of Temporomandibular Joint Ankylosis.

    Science.gov (United States)

    Sun, Guowen; Lu, Mingxing; Hu, Qingang

    2015-11-01

    The purpose of this study was to assess the safety and the accuracy of surgical navigation technology in the resection of severe ankylosis of the mandibular condyle with the middle cranial fossa. The computed tomography scan data were transferred to a Windows-based computer workstation, and the patient's individual anatomy was assessed in multiplanar views at the workstation. In the operation, the patient and the virtual image were matched by individual registration with the reference points which were set on the skull bone surface and the teeth. Then, the real-time navigation can be performed. The acquisition of the data sets was uncomplicated, and image quality was sufficient to assess the operative result in 2 cases. Both of the operations were performed successfully with the guidance of real-time navigation. The application of surgical navigation has enhanced the safety and the accuracy of the surgery for bony ankylosis of temporomandibular joint. The use of surgical navigation resulted in the promotion of accurate and safe surgical excision of the ankylosed skull base tissue.

  11. Endoscopes and robots for tight surgical spaces: use of precurved elastic elements to enhance curvature

    Science.gov (United States)

    Remirez, Andria A.; Webster, Robert J.

    2016-03-01

    Many applications in medicine require flexible surgical manipulators and endoscopes capable of reaching tight curvatures. The maximum curvature these devices can achieve is often restricted either by a strain limit, or by a maximum actuation force that the device's components can tolerate without risking mechanical failure. In this paper we propose the use of precurvature to "bias" the workspace of the device in one direction. Combined with axial shaft rotation, biasing increases the size of the device's workspace, enabling it to reach tighter curvatures than a comparable device without biasing can achieve, while still being able to fully straighten. To illustrate this effect, we describe several example prototype devices which use flexible nitinol strips that can be pushed and pulled to generate bending. We provide a statics model that relates the manipulator curvature to actuation force, and validate it experimentally.

  12. Assessing the costs of disposable and reusable supplies wasted during surgeries.

    Science.gov (United States)

    Chasseigne, V; Leguelinel-Blache, G; Nguyen, T L; de Tayrac, R; Prudhomme, M; Kinowski, J M; Costa, P

    2018-05-01

    The management of disposable and reusable supplies might have an impact on the cost efficiency of the Operating Room (OR). This study aimed to evaluate the cost and reasons for wasted supplies in the OR during surgical procedures. We conducted an observational and prospective study in a French university hospital. We assessed the cost of wasted supplies in the OR (defined by opened unused devices), the reasons for the wastage, and the circulator retrievals. At the end, we assessed the perception of surgeons and nurses relative to the supply wastage. Fifty routine procedures and five non-scheduled procedures were observed in digestive (n = 20), urologic (n = 20) and gynecologic surgery (n = 15). The median cost [IQR] of open unused devices was €4.1 [0.5; 10.5] per procedure. Wasted supplies represented up to 20.1% of the total cost allocated to surgical supplies. Considering the 8000 surgical procedures performed in these three surgery departments, the potential annual cost savings were 100 000€. The most common reason of wastage was an anticipation of the surgeon's needs. The circulating nurse spent up to 26.3% of operative time outside of the OR, mainly attending to an additional demand from the surgeon (30%). Most of the survey respondents (68%) agreed that knowing supply prices would change their behavior. This study showed the OR is a major source of wasted hospital expenditure and an area wherein an intervention would have a significant impact. Reducing wasted supplies could improve the cost efficiency of the OR and also decrease its ecological impact. Copyright © 2018 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  13. Solitary rectal ulcer syndrome: clinical findings, surgical treatment, and outcomes.

    Science.gov (United States)

    Torres, Carlos; Khaikin, Marat; Bracho, Jorge; Luo, Cheng Hua; Weiss, Eric G; Sands, Dana R; Cera, Susan; Nogueras, Juan J; Wexner, Steven D

    2007-11-01

    Solitary rectal ulcer syndrome (SRUS) is a rare disorder often misdiagnosed as a malignant ulcer. Histopathological features of SRUS are characteristic and pathognomonic; nevertheless, the endoscopic and clinical presentations may be confusing. The aim of the present study was to assess the clinical findings, surgical treatment, and outcomes in patients who suffer from SRUS. A retrospective chart review was undertaken, from January 1989 to May 2005 for all patients who were diagnosed with SRUS. Data recorded included: patient's age, gender, clinical presentation, past surgical history, diagnostic and preoperative workup, operative procedure, complications, and outcomes. During the study period, 23 patients were diagnosed with SRUS. Seven patients received only medical treatment, and in three patients, the ulcer healed after medical treatment. Sixteen patients underwent surgical treatment. In four patients, the symptoms persisted after surgery. Two patients presented with postoperative rectal bleeding requiring surgical intervention. Three patients developed late postoperative sexual dysfunction. One patient continued suffering from rectal pain after a colostomy was constructed. Median follow-up was 14 (range 2-84) months. The results of this study show clearly that every patient with SRUS must be assessed individually. Initial treatment should include conservative measures. In patients with refractory symptoms, surgical treatment should be considered. Results of anterior resection and protocolectomy are satisfactory for solitary rectal ulcer.

  14. Virtual Reality Simulation as a Tool to Monitor Surgical Performance Indicators: VIRESI Observational Study.

    Science.gov (United States)

    Muralha, Nuno; Oliveira, Manuel; Ferreira, Maria Amélia; Costa-Maia, José

    2017-05-31

    Virtual reality simulation is a topic of discussion as a complementary tool to traditional laparoscopic surgical training in the operating room. However, it is unclear whether virtual reality training can have an impact on the surgical performance of advanced laparoscopic procedures. Our objective was to assess the ability of the virtual reality simulator LAP Mentor to identify and quantify changes in surgical performance indicators, after LAP Mentor training for digestive anastomosis. Twelve surgeons from Centro Hospitalar de São João in Porto (Portugal) performed two sessions of advanced task 5: anastomosis in LAP Mentor, before and after completing the tutorial, and were evaluated on 34 surgical performance indicators. The results show that six surgical performance indicators significantly changed after LAP Mentor training. The surgeons performed the task significantly faster as the median 'total time' significantly reduced (p virtual reality training simulation as a benchmark tool to assess the surgical performance of Portuguese surgeons. LAP Mentor is able to identify variations in surgical performance indicators of digestive anastomosis.

  15. Thermal comfort assessment of a surgical room through computational fluid dynamics using local PMV index.

    Science.gov (United States)

    Rodrigues, Nelson J O; Oliveira, Ricardo F; Teixeira, Senhorinha F C F; Miguel, Alberto Sérgio; Teixeira, José Carlos; Baptista, João S

    2015-01-01

    Studies concerning indoor thermal conditions are very important in defining the satisfactory comfort range in health care facilities. This study focuses on the evaluation of the thermal comfort sensation felt by surgeons and nurses, in an orthopaedic surgical room of a Portuguese hospital. Two cases are assessed, with and without the presence of a person. Computational fluid dynamic (CFD) tools were applied for evaluating the predicted mean vote (PMV) index locally. Using average ventilation values to calculate the PMV index does not provide a correct and enough descriptive evaluation of the surgical room thermal environment. As studied for both cases, surgeons feel the environment slightly hotter than nurses. The nurses feel a slightly cold sensation under the air supply diffuser and their neutral comfort zone is located in the air stagnation zones close to the walls, while the surgeons feel the opposite. It was observed that the presence of a person in the room leads to an increase of the PMV index for surgeons and nurses. That goes in line with the empirical knowledge that more persons in a room lead to an increased heat sensation. The clothing used by both classes, as well as the ventilation conditions, should be revised accordingly to the amount of persons in the room and the type of activity performed.

  16. Recruitment to publicly funded trials--are surgical trials really different?

    Science.gov (United States)

    Cook, Jonathan A; Ramsay, Craig R; Norrie, John

    2008-09-01

    Good recruitment is integral to the conduct of a high-quality randomised controlled trial. It has been suggested that recruitment is particularly difficult for evaluations of surgical interventions, a field in which there is a dearth of evidence from randomised comparisons. While there is anecdotal speculation to support the inference that recruitment to surgical trials is more challenging than for medical trials we are unaware of any formal assessment of this. In this paper, we compare recruitment to surgical and medical trials using a cohort of publicly funded trials. Overall recruitment to trials was assessed using of a cohort of publicly funded trials (n=114). Comparisons were made by using the Recruitment Index, a simple measure of recruitment activity for multicentre randomised controlled trials. Recruitment at the centre level was also investigated through three example surgical trials. The Recruitment Index was found to be higher, though not statistically significantly, in the surgical group (n=18, median=38.0 IQR (10.7, 77.4)) versus (n=81, median=34.8 IQR (11.7, 98.0)) days per recruit for the medical group (median difference 1.7 (-19.2, 25.1); p=0.828). For the trials where the comparison was between a surgical and a medical intervention, the Recruitment Index was substantially higher (n=6, 68.3 (23.5, 294.8)) versus (n=93, 34.6 (11.7, 90.0); median difference 25.9 (-35.5, 221.8); p=0.291) for the other trials. There was no clear evidence that surgical trials differ from medical trials in terms of recruitment activity. There was, however, support for the inference that medical versus surgical trials are more difficult to recruit to. Formal exploration of the recruitment data through a modelling approach may go some way to tease out where important differences exist.

  17. Current Capabilities and Development Potential in Surgical Robotics

    Directory of Open Access Journals (Sweden)

    Mathias Hoeckelmann

    2015-05-01

    Full Text Available Commercial surgical robots have been in clinical use since the mid-1990s, supporting surgeons in various tasks. In the past decades, many systems emerged as research platforms, and a few entered the global market. This paper summarizes the currently available surgical systems and research directions in the broader field of surgical robotics. The widely deployed teleoperated manipulators aim to enhance human cognitive and physical skills and provide smart tools for surgeons, while image-guided robotics focus on surpassing human limitations by introducing automated targeting and treatment delivery methods. Both concepts are discussed based on prototypes and commercial systems. Through concrete examples the possible future development paths of surgical robots are illustrated. While research efforts are taking different approaches to improve the capacity of such systems, the aim of this survey is to assess their maturity from the commercialization point of view.

  18. Can a teaching assistant experience in a surgical anatomy course influence the learning curve for nontechnical skill development for surgical residents?

    Science.gov (United States)

    Heidenreich, Mark J; Musonza, Tashinga; Pawlina, Wojciech; Lachman, Nirusha

    2016-01-01

    The foundation upon which surgical residents are trained to work comprises more than just critical cognitive, clinical, and technical skill. In an environment where the synchronous application of expertise is vital to patient outcomes, the expectation for optimal functioning within a multidisciplinary team is extremely high. Studies have shown that for most residents, one of the most difficult milestones in the path to achieving professional expertise in a surgical career is overcoming the learning curve. This view point commentary provides a reflection from the two senior medical students who have participated in the Student-as-Teacher program developed by the Department of Anatomy at Mayo Clinic, designed to prepare students for their teaching assistant (TA) role in anatomy courses. Both students participated as TAs in a six week surgical anatomy course for surgical first assistant students offered by the School of Health Sciences at Mayo Clinic. Development of teaching skills, nontechnical leadership, communication, and assessment skills, are discussed in relation to their benefits in preparing senior medical students for surgical residency. © 2015 American Association of Anatomists.

  19. The Potential of Devices for HFpEF

    Directory of Open Access Journals (Sweden)

    Andrew J Stewart Coats

    2017-01-01

    Full Text Available The 2016 ESC/HFA HF guidelines list the very many drug and device therapies that are proven to be beneficial in terms of life prolongation and hospitalisation prevention for HFrEF. The list of recommended therapies or devices for HFpEF and HFmrEF is limited to diuretics and the management of comorbidities and so far there is no clinical evidence for an electrical or mechanical device for HFpEF. The Cardiac Contractility Modulation (CCM device that may have a role in selected HFrEF and HFmrEF patients has been reviewed in another paper in this issue but here we survey the results so far of a novel device for patients with HFpEF. Despite lagging many years behind HFrEF, HFpEF patients are now being targeted with novel devices with the potential to improve symptoms, improve quality of life, reduce hospitalization and delay progression of the syndrome. The front-runner is a novel inter-atrial left atrial pressure decompression device the Corvia IASD, which currently enrolling patients in a randomized trial. This device is a CE-marked investigational, non- surgical transcatheter implant designed to provide continuous and dynamic decompression of the left atrium, in an effort to reduce symptoms, HF hospitalizations, and improve quality of life as well as potentially slowing the progression of HFpEF.

  20. Perioperative blood transfusion does not decrease survival after surgical treatment of spinal metastases

    DEFF Research Database (Denmark)

    Clausen, Caroline; Lönn, Lars; Morgen, Søren Schmidt

    2014-01-01

    PURPOSE: To assess whether perioperative allogenic blood transfusions in patients undergoing surgical treatment for spinal metastases independently influence patient survival. METHODS: A retrospective study including 170 consecutive patients undergoing surgical treatment for spinal metastases in ...... 12-month survival. Future studies should assess if a liberal transfusion regime can be applied to this group of patients; thereby, prioritizing early postoperative mobilization....

  1. [Piezosurgery for surgically assisted rapid maxillary expansion under local anesthesia].

    Science.gov (United States)

    Sun, Hao; Li, Biao; Sun, Hao; Liu, Zhixu; Wang, Xudong

    2014-08-01

    This study evaluates piezosurgery for surgically assisted rapid maxillary expansion (SARME) under local anesthesia. SARME was performed on adults with maxillary transverse deficiency under local anesthesia with a piezosurgical device. Fourteen patients (six males and eight females) underwent lateral maxillary osteotomies, midpalatal osteotomies, and bilateral pterygomaxillary disjunction. The feelings of patients during the operation were determined through questionnaires. All patients underwent SARME in the out-patient operating room. The surgical procedures were completed under local anesthesia. All patients exhibited satisfactory tolerance. Ultrasonic bone-cutting surgery was recently introduced as a feasible alternative to the conventional tools of cranio-maxillofacial surgery for its technical characteristics of precision and safety. The device used was unique in that cutting action occurred when the tool was employed on mineralized tissues, but stoped on soft tissues. The results of the questionnaires showed that eight (57.14%) patients felt a mild sensation of ultrasonic vibration, tweleve (85.7 1%) felt mild tolerable pain and tooth soreness during surgery, and eleven (78.57%) felt little fear and hardly heard the ultrasonic sound. Preoperative and postoperative six months later measurements showed an evident effect of expansion. Piezosurgery enabled patients to undergo all the steps of SARME under local anesthesia, but more cases and longer follow-up are needed to verif ' the results.

  2. Intracavitary deposits on Essure® hysteroscopic sterilization devices : A case report

    NARCIS (Netherlands)

    Maassen, L. W.; van Gastel, Maatje D A; Lentjes, E. G.W.M.; Bongers, M. Y.; Veersema, S.

    2017-01-01

    Objective To study the composition of intracavitary deposits on Essure® hysteroscopic sterilization devices. Design Case report. Setting Reproductive Medicine and Gynecology department of a University Hospital. Patient(s) A 39 years old patient presenting with a request for surgical removal of

  3. Measuring the Burden of Surgical Disease Averted by Emergency and Essential Surgical Care in a District Hospital in Papua New Guinea.

    Science.gov (United States)

    Stokes, Matthew A R; Guest, Glenn D; Mamadi, Perista; Seta, Westin; Yaubihi, Noel; Karawiga, Grace; Naidi, Billy; Watters, David A K

    2017-03-01

    Timely access to emergency and essential surgical care (EESC) and anaesthesia in low- and middle-income countries (LMICs) prevents premature death, minimises lifelong disability and reduces their economic impact on families and communities. Papua New Guinea is one of the poorest countries in the Pacific region, and provides much of its surgical care at a district hospital level. We aimed to evaluate the surgical capacity of a district hospital in PNG and estimate the effectiveness of surgical interventions provided. We performed a prospective study to calculate the number of DALYs averted for 465 patients treated with surgical care over a 3-month period (Sep-Nov 2013) in Alotau Hospital, Milne Bay Province, PNG (pop 210,000). Data were also collected on infrastructure, workforce, interventions provided and equipment available using the World Health Organization's Integrated Management of Emergency and Essential Surgical Care Toolkit, a survey to assess EESC and surgical capacity. We also performed a retrospective one-year audit of surgical, obstetric and anaesthetic care to provide context with regards to annual disease burden treated and surgical activity. EESC was provided by 11 Surgeons/Anaesthetists/Obstetricians (SAO) providers, equating to 5.7 per 100,000 population (including 4 nurse anaesthetists). They performed 783/100,000 procedures annually. Over the 3-month prospective study period, 4954 DALYs were averted by 465 surgical interventions, 52 % of which were elective. This equates to 18,330 DALYs averted annually or, approximately 18 % of the published but estimated disease burden in the Province in the 2013 Global Burden of Disease Study. The overall peri-operative mortality rate was 1.29 %, with 0.41 % for elective procedures and 2.25 % for emergencies. Much of the burden of surgical disease in Papua New Guinea presenting to Alotau General Hospital serving Milne Bay Province can be effectively treated by a small team providing emergency and

  4. The Application of Minimally Invasive Devices with Nanostructured Surface Functionalization: Antisticking Behavior on Devices and Liver Tissue Interface in Rat

    Directory of Open Access Journals (Sweden)

    Li-Hsiang Lin

    2015-01-01

    Full Text Available This study investigated the thermal injury and adhesion property of a novel electrosurgery of liver using copper-doped diamond-like carbon (DLC-Cu surface treatment. It is necessary to reduce the thermal damage of surrounding tissues for clinical electrosurgeries. The surface morphologies of stainless steel (SS coated with DLC (DLC-Cu-SS films were characterized by scanning electron microscopy (SEM and transmission electron microscopy (TEM. Bionic liver models were reconstructed using magnetic resonance imaging (MRI to simulate electrosurgery. Cell cytotoxicity assays showed that the DLC-Cu thin film was nontoxic. The temperature of tissue decreased significantly with use of the electrosurgical device with nanostructured DLC-Cu films and increased with increasing thickness of the films. Thermography revealed that the surgical temperature in the DLC-Cu-SS electrosurgical device was significantly lower than that in the untreated device in the animal model. Moreover, compared to the SS electrosurgical device, the DLC-Cu-SS electrosurgical device caused a relatively small injury area and lateral thermal effect. The results indicate that the DLC-Cu-SS electrosurgical device decreases excessive thermal injury and ensures homogeneous temperature transformation in the tissues.

  5. Use of a mobile device by nursing home residents for long-term care comprehensive geriatric self-assessment: a feasibility study.

    Science.gov (United States)

    Huang, Fanpin; Chang, Polun; Hou, I-Ching; Tu, Ming-Hsiang; Lan, Chung-Fu

    2015-01-01

    Long-term-care comprehensive geriatric assessments, such as the Minimum Data Set 3.0, are used to evaluate the clinical, psychological, and personal status of residents in long-term-care nursing facilities. Nursing staff conducts assessment interviews, thereby increasing the workload of nurses and the cost of patient care. This study explored the ability of nursing home residents to use two different mobile devices for a geriatric self-assessment. Study participants were residents of long-term-care nursing homes. A modified Minimum Data Set 3.0 was converted to a format for use with a 6-inch mobile pad and a 3.7-inch mobile smartphone. The survey completion rate and the response time were measured. A Technology Assessment Model questionnaire analyzed the participants' experience. All participants were able to use a 6-inch pad, with an average completion rate of 92.9% and an average time for completion of 21 minutes. Only 20% of the participants could complete the assessment with the 3.7-inch smartphone. The participants found the 6-inch pad easier to use than the 3.7-inch smartphone. This exploratory study suggests that nursing home residents are able to use a mobile device to perform a geriatric self-assessment and delineates the importance of the ergonomics of the device.

  6. Is anemia associated with cognitive impairment and delirium among older acute surgical patients?

    Science.gov (United States)

    Myint, Phyo Kyaw; Owen, Stephanie; McCarthy, Kathryn; Pearce, Lyndsay; Moug, Susan J; Stechman, Michael J; Hewitt, Jonathan; Carter, Ben

    2018-03-01

    The determinants of cognitive impairment and delirium during acute illness are poorly understood, despite being common among older people. Anemia is common in older people, and there is ongoing debate regarding the association between anemia, cognitive impairment and delirium, primarily in non-surgical patients. Using data from the Older Persons Surgical Outcomes Collaboration 2013 and 2014 audit cycles, we examined the association between anemia and cognitive outcomes in patients aged ≥65 years admitted to five UK acute surgical units. On admission, the Confusion Assessment Method was carried out to detect delirium. Cognition was assessed using the Montreal Cognitive Assessment, and two levels of impairment were defined as Montreal Cognitive Assessment cognitive impairment or delirium. The adjusted odds ratios of cognitive impairment were 0.95 (95% CI 0.56-1.61) and 1.00 (95% CI 0.61-1.64) for the Montreal Cognitive Assessment cognitive outcomes among older people in this acute surgical setting. Considering the retrospective nature of the study and possible lack of power, findings should be taken with caution. Geriatr Gerontol Int 2018; ••: ••-••. © 2018 The Authors Geriatrics & Gerontology International published by John Wiley & Sons Australia, Ltd on behalf of Japan Geriatrics Society.

  7. Performance characteristics of a novel blood bag in-line closure device and subsequent product quality assessment

    Science.gov (United States)

    Serrano, Katherine; Levin, Elena; Culibrk, Brankica; Weiss, Sandra; Scammell, Ken; Boecker, Wolfgang F; Devine, Dana V

    2010-01-01

    BACKGROUND In high-volume processing environments, manual breakage of in-line closures can result in repetitive strain injury (RSI). Furthermore, these closures may be incorrectly opened causing shear-induced hemolysis. To overcome the variability of in-line closure use and minimize RSI, Fresenius Kabi developed a new in-line closure, the CompoFlow, with mechanical openers. STUDY DESIGN AND METHODS The consistency of the performance of the CompoFlow closure device was assessed, as was its effect on component quality. A total of 188 RBC units using CompoFlow blood bag systems and 43 using the standard bag systems were produced using the buffy coat manufacturing method. Twenty-six CompoFlow platelet (PLT) concentrates and 10 control concentrates were prepared from pools of four buffy coats. RBCs were assessed on Days 1, 21, and 42 for cellular variables and hemolysis. PLTs were assessed on Days 1, 3, and 7 for morphology, CD62P expression, glucose, lactate, and pH. A total of 308 closures were excised after processing and the apertures were measured using digital image analysis. RESULTS The use of the CompoFlow device significantly improved the mean extraction time with 0.46 ± 0.11 sec/mL for the CompoFlow units and 0.52 ± 0.13 sec/mL for the control units. The CompoFlow closures showed a highly reproducible aperture after opening (coefficient of variation, 15%) and the device always remained opened. PLT and RBC products showed acceptable storage variables with no differences between CompoFlow and control. CONCLUSIONS The CompoFlow closure devices improved the level of process control and processing time of blood component production with no negative effects on product quality. PMID:20529007

  8. Stereotaxic percutaneous core biopsy versus surgical biopsy of nonpalpable breast lesions using a standard mammographic table with an add-on device

    International Nuclear Information System (INIS)

    Levin, M.F.; Papoff, W.J.; Doan, L.; Eliasziw, M.

    2001-01-01

    To determine the accuracy of using a regular mammographic table with an add-on device for biopsy of nonpalpable breast lesions in women in a community hospital setting. During a 3-year period, 70 consenting women (39-80 years of age) with a nonpalpable mammographically suspicious lesion on routine screening mammography underwent 14-gauge automated percutaneous core biopsies, immediate needle localization and lumpectomy. The needle and surgical biopsy results were independently classified into 1 of 5 categories: cancer, fibroadenomal fibrocystic change, normal or other. The procedure was well tolerated, and all core specimens yielded adequate tissue for pathologic evaluation. There were 3 episodes of vasovagal reaction. There was complete agreement in histologic findings in 64 cases (91%), including 22 of 24 cancers (92%). The overall agreement for categorizing lesions was 91% (k 0.88), and there was 97% agreement (k = 0.94) for the classification of cancer versus benign lesion. The results are similar to those of studies performed with dedicated prone equipment. Stereotaxic core biopsies can be done safely and accurately in a community hospital setting with relatively inexpensive nondedicated mammographic equipment. (author)

  9. Stereotaxic percutaneous core biopsy versus surgical biopsy of nonpalpable breast lesions using a standard mammographic table with an add-on device

    Energy Technology Data Exchange (ETDEWEB)

    Levin, M.F.; Papoff, W.J.; Doan, L.; Eliasziw, M. [St. Thomas-Elgin General Hospital, St. Thomas, Ontario (Canada)

    2001-02-01

    To determine the accuracy of using a regular mammographic table with an add-on device for biopsy of nonpalpable breast lesions in women in a community hospital setting. During a 3-year period, 70 consenting women (39-80 years of age) with a nonpalpable mammographically suspicious lesion on routine screening mammography underwent 14-gauge automated percutaneous core biopsies, immediate needle localization and lumpectomy. The needle and surgical biopsy results were independently classified into 1 of 5 categories: cancer, fibroadenomal fibrocystic change, normal or other. The procedure was well tolerated, and all core specimens yielded adequate tissue for pathologic evaluation. There were 3 episodes of vasovagal reaction. There was complete agreement in histologic findings in 64 cases (91%), including 22 of 24 cancers (92%). The overall agreement for categorizing lesions was 91% (k 0.88), and there was 97% agreement (k = 0.94) for the classification of cancer versus benign lesion. The results are similar to those of studies performed with dedicated prone equipment. Stereotaxic core biopsies can be done safely and accurately in a community hospital setting with relatively inexpensive nondedicated mammographic equipment. (author)

  10. Micro-surgical endodontics.

    Science.gov (United States)

    Eliyas, S; Vere, J; Ali, Z; Harris, I

    2014-02-01

    Non-surgical endodontic retreatment is the treatment of choice for endodontically treated teeth with recurrent or residual disease in the majority of cases. In some cases, surgical endodontic treatment is indicated. Successful micro-surgical endodontic treatment depends on the accuracy of diagnosis, appropriate case selection, the quality of the surgical skills, and the application of the most appropriate haemostatic agents and biomaterials. This article describes the armamentarium and technical procedures involved in performing micro-surgical endodontics to a high standard.

  11. Intracranial aneurysms: reproduction of the surgical view using 3D-CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Siablis, Dimitrios [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece)]. E-mail: siablis@med.upatras.gr; Kagadis, George C. [Department of Medical Physics, School of Medicine, University of Patras, Rion GR 26500 (Greece); Karamessini, Maria T. [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece); Konstantinou, Dimitrios [Department of Neurosurgery, School of Medicine, University of Patras, Rion GR 26500 (Greece); Karnabatidis, Dimitrios [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece); Petsas, Theodore [Department of Radiology, School of Medicine, University of Patras, Rion GR 26500 (Greece); Nikiforidis, George C. [Department of Medical Physics, School of Medicine, University of Patras, Rion GR 26500 (Greece)

    2005-07-01

    Our purpose was to describe a technique for simulating the surgical view of ruptured intracranial aneurysms, using volume-rendering techniques in spiral computed tomography (CT) angiography data. The 3D (three-dimensional) rendered images were assessed by a team consisted of four radiologists, one neurosurgeon and one medical physicist. The resultant 'surgical view' image was standardized in space using a three-dimensional coordinate system, which allowed for its reproduction in the operating theatre. The surgical views are a potentially useful tool for the surgical planning of intracranial aneurysms.

  12. Intracranial aneurysms: reproduction of the surgical view using 3D-CT angiography

    International Nuclear Information System (INIS)

    Siablis, Dimitrios; Kagadis, George C.; Karamessini, Maria T.; Konstantinou, Dimitrios; Karnabatidis, Dimitrios; Petsas, Theodore; Nikiforidis, George C.

    2005-01-01

    Our purpose was to describe a technique for simulating the surgical view of ruptured intracranial aneurysms, using volume-rendering techniques in spiral computed tomography (CT) angiography data. The 3D (three-dimensional) rendered images were assessed by a team consisted of four radiologists, one neurosurgeon and one medical physicist. The resultant 'surgical view' image was standardized in space using a three-dimensional coordinate system, which allowed for its reproduction in the operating theatre. The surgical views are a potentially useful tool for the surgical planning of intracranial aneurysms

  13. Longitudinal Assessments of Quality of Life in Endometrial Cancer Patients: Effect of Surgical Approach and Adjuvant Radiotherapy

    International Nuclear Information System (INIS)

    Le, Tien; Menard, Chantal; Samant, Rajiv; Choan, E.; Hopkins, Laura; Faught, Wylam; Fung-Kee-Fung, Michael

    2009-01-01

    Purpose: Adjuvant radiotherapy (RT) is often considered for endometrial cancer. We studied the effect of RT and surgical treatment on patients' quality of life (QOL). Methods and Materials: All patients referred to the gynecologic oncology clinics with biopsy findings showing endometrial cancer were recruited. QOL assessments were performed using the European Organization for Research and Treatment of Cancer QOL questionnaire-C30, version 3. Assessments were obtained at study entry and at regular 3-month intervals for a maximum of 2 years. Open-ended telephone interviews were done every 6 months. Linear mixed regression models were built using QOL domain scores as dependent variables, with the predictors of surgical treatment and adjuvant RT type. Results: A total of 40 patients were recruited; 80% of the surgeries were performed by laparotomy. Significant improvements were seen in most QOL domains with increased time from treatment. Adjuvant RT resulted in significantly more severe bowel symptoms and improvement in insomnia compared with conservative follow-up. No significant adverse effect from adjuvant RT was seen on the overall QOL. Bowel symptoms were significantly increased in patients treated with laparotomy compared with laparoscopy in the patients treated with whole pelvic RT. Qualitatively, about one-half of the patients noted improvements in their overall QOL during follow-up, with easy fatigability the most prevalent. Conclusion: No significant adverse effect was seen on patients' overall QOL with adjuvant pelvic RT after the recovery period. The acute adverse effects on patients' QOL significantly improved with an increasing interval from diagnosis.

  14. Perioperative management for the prevention of bacterial infection in cardiac implantable electronic device placement

    Directory of Open Access Journals (Sweden)

    Katsuhiko Imai

    2016-08-01

    Full Text Available Cardiac implantable electronic devices (CIEDs have become important in the treatment of cardiac disease and placement rates increased significantly in the last decade. However, despite the use of appropriate antimicrobial prophylaxis, CIED infection rates are increasing disproportionately to the implantation rate. CIED infection often requires explantation of all hardware, and at times results in death. Surgical site infection (SSI is the most common cause of CIED infection as a pocket infection. The best method of combating CIED infection is prevention. Prevention of CIED infections comprises three phases: before, during, and after device implantation. The most critical factors in the prevention of SSIs are detailed operative techniques including the practice of proper technique by the surgeon and surgical team.

  15. Meta-Review of the Quantity and Quality of Evidence for Knee Arthroplasty Devices.

    Directory of Open Access Journals (Sweden)

    Anna R Gagliardi

    Full Text Available Some cardiovascular devices are licensed based on limited evidence, potentially exposing patients to devices that are not safe or effective. Research is needed to ascertain if the same is true of other types of medical devices. Knee arthroplasty is a widely-used surgical procedure yet implant failures are not uncommon. The purpose of this study was to characterize available evidence on the safety and effectiveness of knee implants.A review of primary studies included in health technology assessments (HTA on total (TKA and unicompartmental knee arthroplasty (UKA was conducted. MEDLINE, EMBASE, CINAHL, Cochrane Library and Biotechnology & BioEngineering Abstracts were searched from 2005 to 2014, plus journal tables of contents and 32 HTA web sites. Patients were aged 18 and older who underwent primary TKA or UKA assessed in cohort or randomized controlled studies. Summary statistics were used to report study characteristics.A total of 265 eligible primary studies published between 1986 and 2014 involving 59,217 patients were identified in 10 HTAs (2 low, 7 moderate, 1 high risk of bias. Most evaluated TKA (198, 74.5%. The quality of evidence in primary studies was limited. Most studies were industry-funded (23.8% or offered no declaration of funding or conflict of interest (44.9%; based on uncontrolled single cohorts (58.5%, enrolled fewer than 100 patients (66.4%, and followed patients for 2 years or less (UKA: single cohort 29.8%, comparative cohort 16.7%, randomized trial 25.0%; TKA: single cohort 25.0%, comparative cohort 31.4%, randomized trial 48.6%. Furthermore, most devices were evaluated in only one study (55.3% TKA implants, 61.1% UKA implants.Patients, physicians, hospitals and payers rely on poor-quality evidence to support decisions about knee implants. Further research is needed to explore how decisions about the use of devices are currently made, and how the evidence base for device safety and effectiveness can be strengthened.

  16. Surgical treatment of polymicrogyria-related epilepsy.

    Science.gov (United States)

    Cossu, Massimo; Pelliccia, Veronica; Gozzo, Francesca; Casaceli, Giuseppe; Francione, Stefano; Nobili, Lino; Mai, Roberto; Castana, Laura; Sartori, Ivana; Cardinale, Francesco; Lo Russo, Giorgio; Tassi, Laura

    2016-12-01

    The role of resective surgery in the treatment of polymicrogyria (PMG)-related focal epilepsy is uncertain. Our aim was to retrospectively evaluate the seizure outcome in a consecutive series of patients with PMG-related epilepsy who received, or did not receive, surgical treatment, and to outline the clinical characteristics of patients who underwent surgery. We evaluated 64 patients with epilepsy associated with magnetic resonance imaging (MRI)-documented PMG. After presurgical evaluation, 32 patients were excluded from surgical treatment and 32 were offered surgery, which was declined by 8 patients. Seizure outcome was assessed in the 40 nonsurgical and 24 surgical patients. Of 40 nonsurgical patients, 8 (20%) were seizure-free after a mean follow-up of 91.7 ± (standard deviation) 59.5 months. None of the eight patients who declined surgical treatment was seizure-free (mean follow-up: 74.3 ± 60.6 months). These seizure outcomes differ significantly (p = 0.000005 and p = 0.0003, respectively) from that of the 24 surgical patients, 18 of whom (66.7%) were Engel's class I postoperatively (mean follow-up: 66.5 ± 54.0 months). Of the eight patients excluded from surgery for seizure control at first visit, two had seizure recurrence at last contact. At last contact, antiepileptic drugs (AEDs) had been withdrawn in 6 of 24 surgical and in one of 40 nonsurgical cases (p = 0.0092). The present study indicates that, at least in a subset of adequately selected patients with PMG-related epilepsy, surgery may provide excellent seizure outcomes. Furthermore, it suggests that surgery is superior to AEDs for achieving seizure freedom in these cases. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  17. Phase-contrast MR assessment of pulmonary venous blood flow in children with surgically repaired pulmonary veins

    International Nuclear Information System (INIS)

    Valsangiacomo, Emanuela R.; Yoo, Shi-Joon; Barrea, Catherine; Smallhorn, Jeffrey F.; Macgowan, Christopher K.; Coles, John G.

    2003-01-01

    Pulmonary venous (PV) obstruction may complicate surgical repair of PV abnormalities. By combining phase-contrast cine (PC) imaging and contrast-enhanced angiography, magnetic resonance (MR) imaging can provide physiological information complementing anatomical diagnosis. To compare the PV flow pattern observed after surgical repair of PV abnormalities with normal PV flow pattern and to investigate the changes occurring in the presence of PV stenosis by using PC MR in children. By using PC MR, PV flow was evaluated in 14 patients (3 months-14 years) who underwent surgical repair for PV abnormalities. Eleven children (8-18 years) were studied as normal controls. Peak flow velocities and patterns were compared among three groups: normal veins (n=23), surgically repaired veins without (n=44) and with stenosis (n=10). Normal and unobstructed pulmonary veins after surgery showed a biphasic or triphasic flow pattern with one or two systolic peaks and a diastolic peak. Unobstructed surgically repaired veins showed decreased peak systolic velocity (P =0.001) and an increased peak diastolic velocity (P=0.005) when compared to normal values. Obstructed veins showed decreased systolic and diastolic velocities when measured upstream from the stenosis. PC MR shows different flow patterns among normal, surgically repaired pulmonary veins with and without stenosis. (orig.)

  18. Assessing cataract surgical competency

    NARCIS (Netherlands)

    Lee, Andrew G.; Greenlee, Emily; Oetting, Thomas A.; Beaver, Hilary A.; Johnson, A. Tim; Boldt, H. Culver; Abramoff, Michael; Olson, Richard; Carter, Keith

    2007-01-01

    The Accreditation Council for Graduate Medical Education has mandated that all residency training programs teach and assess 6 general competencies.1 A.G. Lee and K.D. Carter, Managing the new mandate in resident education: A blueprint for translating a national mandate into local compliance,

  19. Better evidence for earlier assessment and surgical intervention for refractory epilepsy (The BEST study): a mixed methods study protocol.

    Science.gov (United States)

    Rapport, Frances; Shih, Patti; Mitchell, Rebecca; Nikpour, Armin; Bleasel, Andrew; Herkes, Geoffrey; Vagholkar, Sanjyot; Mumford, Virginia

    2017-08-21

    One-third of patients with refractory epilepsy may be candidates for resective surgery, which can lead to positive clinical outcomes if efficiently managed. In Australia, there is currently between a 6-month and 2-year delay for patients who are candidates for respective epilepsy surgery from the point of referral for surgical assessment to the eventual surgical intervention. This is a major challenge for implementation of effective treatment for individuals who could potentially benefit from surgery. This study examines implications of delays following the point of eligibility for surgery, in the assessment and treatment of patients, and the factors causing treatment delays. Mixed methods design: Observations of qualitative consultations, patient and healthcare professional interviews, and health-related quality of life assessments for a group of 10 patients and six healthcare professionals (group 1); quantitative retrospective medical records' reviews examining longitudinal outcomes for 50 patients assessed for, or undergoing, resective surgery between 2014 and 2016 (group 2); retrospective epidemiological study of all individuals hospitalised with a diagnosis of epilepsy in New South Wales (NSW) in the last 5 years (2012-2016; approximately 11 000 hospitalisations per year, total 55 000), examining health services' use and treatment for individuals with epilepsy, including refractory surgery outcomes (group 3). Ethical approval has been granted by the North Sydney Local Health District Human Research Ethics Committee (HREC/17/HAWKE/22) and the NSW Population & Health Services Research Ethics Committee (HREC/16/CIPHS/1). Results will be disseminated through publications, reports and conference presentations to patients and families, health professionals and researchers. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Quantifying surgical access in eyebrow craniotomy with and without orbital bar removal: cadaver and surgical phantom studies.

    Science.gov (United States)

    Zador, Zsolt; Coope, David J; Gnanalingham, Kanna; Lawton, Michael T

    2014-04-01

    Eyebrow craniotomy is a recently described minimally invasive approach for tackling primarily pathology of the anterior skull base. The removal of the orbital bar may further expand the surgical corridor of this exposure, but the extent of benefit is poorly quantified. We assessed the effect of orbital bar removal with regards to surgical access in the eyebrow craniotomy using classic morphometric measurements in cadaver heads. Using surgical phantoms and neuronavigation, we also measured the 'working volume', a new parameter for characterising the volume of surgical access in these approaches. Silicon injected cadaver heads (n = 5) were used for morphometric analysis of the eyebrow craniotomy with and without orbital bar removal. Working depths and 'working areas' of surgical access were measured as defined by key anatomical landmarks. The eyebrow craniotomy with or without orbital bar removal was also simulated using surgical phantoms (n = 3, 90-120 points per trial), calibrated against a frameless neuronavigation system. Working volume was derived from reference coordinates recorded along the anatomical borders of the eyebrow craniotomy using the "α-shape algorithm" in R statistics. In cadaver heads, eyebrow craniotomy with removal of the orbital bar reduced the working depth to the ipsilateral anterior clinoid process (42 ± 2 versus 33 ± 3 mm; p < 0.05), but the working areas as defined by deep neurovascular and bony landmarks was statistically unchanged (total working areas of 418 ± 80 cm(2) versus 334 ± 48 cm(2); p = 0.4). In surgical phantom studies, however, working-volume for the simulated eyebrow craniotomies was increased with orbital bar removal (16 ± 1 cm(3) versus 21 ± 1 cm(3); p < 0.01). In laboratory studies, orbital bar removal in eyebrow craniotomy provides a modest reduction in working depth and increase in the working volume. But this must be weighed up against the added morbidity of the

  1. Electrocautery Devices With Feedback Mode and Teflon-Coated Blades Create Less Surgical Smoke for a Quality Improvement in the Operating Theater.

    Science.gov (United States)

    Kisch, Tobias; Liodaki, Eirini; Kraemer, Robert; Mailaender, Peter; Brandenburger, Matthias; Hellwig, Veronika; Stang, Felix H

    2015-07-01

    Monopolar electrocautery is a fast and elegant cutting option. However, as it creates surgical smoke containing polycyclic aromatic hydrocarbons (PAHs), it may be hazardous to the health of the surgical team. Although new technologies, such as feedback mode (FM) and Teflon-coated blades (TBs), reduce tissue damage, their impact on surgical smoke creation has not yet been elucidated. Therefore, we analyzed the plume at its source.The aim of this study was to evaluate if electrocautery FM and TBs create less surgical smoke.Porcine tissue containing skin was cut in a standardized manner using sharp-edged Teflon-coated blades (SETBs), normal-shaped TBs, or stainless steel blades (SSBs). Experiments were performed using FM and pure-cut mode. Surgical smoke was sucked through filters or adsorption tubes. Subsequently, filters were scanned and analyzed using a spectrophotometer. A high-performance liquid chromatography (HPLC-UV) was performed to detect benzo[a]pyrene (BaP) and phenanthrene as 2 of the most critical PAHs. Temperature changes at the cutting site were measured by an infrared thermometer.In FM, more surgical smoke was created using SSB compared with TBs (P < 0.001). Furthermore, differences between FM and pure-cut mode were found for SSB and TB (P < 0.001), but not for SETB (P = 0.911). Photometric analysis revealed differences in the peak heights of the PAH spectrum. In HLPC-UV, the amount of BaP and phenanthrene detected was lower for TB compared with SSB. Tissue temperature variations increased when SSB was used in FM and pure-cut mode. Furthermore, different modes revealed higher temperature variations with the use of SETB (P = 0.004) and TB (P = 0.005) during cutting, but not SSB (P = 0.789).We found that the use of both TBs and FM was associated with reduced amounts of surgical smoke created during cutting. Thus, the surgical team may benefit from the adoption of such new technologies, which could contribute to the primary

  2. Surgical Fires and Operative Burns: Lessons Learned From a 33-Year Review of Medical Litigation.

    Science.gov (United States)

    Choudhry, Asad J; Haddad, Nadeem N; Khasawneh, Mohammad A; Cullinane, Daniel C; Zielinski, Martin D

    2017-03-01

    We aimed to understand the setting and litigation outcomes of surgical fires and operative burns. Westlaw, an online legal research data-set, was utilized. Data were collected on patient, procedure, and case characteristics. One hundred thirty-nine cases were identified; 114 (82%) operative burns and 25 (18%) surgical fires. Median plaintiff (patient) age was 46 (IQR:28-59). Most common site of operative burn was the face (26% [n = 36]). Most common source of injury was a high energy device (43% [n = 52]). Death was reported in 2 (1.4%) cases. Plaintiff age <18 vs age 18-50 and mention of a non-surgical physician as a defendant both were shown to be independently associated with an award payout (OR = 4.90 [95% CI, 1.23-25.45]; p = .02) and (OR = 4.50 [95% CI, 1.63-13.63]; p = .003) respectively. Plaintiff award payment (settlement or plaintiff verdict) was reported in 83 (60%) cases; median award payout was $215,000 (IQR: $82,000-$518,000). High energy devices remain as the most common cause of injury. Understanding and addressing pitfalls in operative care may mitigate errors and potentially lessen future liability. III. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Hands-On Surgical Training Workshop: an Active Role-Playing Patient Education for Adolescents.

    Science.gov (United States)

    Wongkietkachorn, Apinut; Boonyawong, Pangpoom; Rhunsiri, Peera; Tantiphlachiva, Kasaya

    2017-09-01

    Most patient education involves passive learning. To improve patient education regarding surgery, an active learning workshop-based teaching method is proposed. The objective of this study was to assess level of patient surgical knowledge, achievement of workshop learning objectives, patient apprehension about future surgery, and participant workshop satisfaction after completing a surgical training workshop. A four-station workshop (surgical scrub, surgical suture, laparoscopic surgery, and robotic surgery) was developed to teach four important components of the surgical process. Healthy, surgery-naive adolescents were enrolled to attend this 1-h workshop-based training program. Training received by participants was technically and procedurally identical to training received by actual surgeons. Pre- and post-workshop questionnaires were used to assess learning outcomes. There were 1312 participants, with a mean age 15.9 ± 1.1 years and a gender breakdown of 303 males and 1009 females. For surgical knowledge, mean pre-workshop and post-workshop scores were 6.1 ± 1.5 and 7.5 ± 1.5 (out of 10 points), respectively (p education is an effective way to improve understanding of surgery-related processes. This teaching method may also decrease apprehension that patients or potential patients harbor regarding a future surgical procedure.

  4. Spectrum of peripheral neuropathies associated with surgical interventions; A neurophysiological assessment.

    LENUS (Irish Health Repository)

    Saidha, Shiv

    2010-01-01

    We hypothesized that a wide range of surgical procedures may be complicated by neuropathies, not just in close proximity but also remote from procedural sites. The aim of this study was to classify post-operative neuropathies and the procedures associated with them.

  5. An analysis of OSHA inspections assessing contaminant exposures in general medical and surgical hospitals.

    Science.gov (United States)

    Knight, Jordan L; Sleeth, Darrah K; Larson, Rodney R; Pahler, Leon F

    2013-04-01

    This study analyzed data from the Occupational Safety and Health Administration's (OSHA) Chemical Exposure Health Database to assess contaminant exposures in general medical and surgical hospitals. Seventy-five inspections conducted in these hospitals from 2005 through 2009 were identified. Five categories of inspections were conducted, the three most common being complaint-based, planned, and referral-based inspections. Complaint-based inspections comprised the majority of inspections-55 (73%) of the 75 conducted. The overall violation rate for all inspection types was 68%. This finding was compared to the violation rates of planned inspections (100%), referral-based inspections (83%), and complaint-based inspections (62%). Asbestos was the hazardous substance most commonly sampled and cited by OSHA in hospitals, with 127 samples collected during 24 inspections; 31% of the total 75 inspections resulting in one or more violations were due to asbestos. Copyright 2013, SLACK Incorporated.

  6. Influence of deep neuromuscular block on the surgeonś assessment of surgical conditions during laparotomy

    DEFF Research Database (Denmark)

    Madsen, M V; Scheppan, S; Mørk, E

    2017-01-01

    Background: During laparotomy, surgeons may experience difficult surgical conditions if the patient's abdominal wall or diaphragm is tense. Deep neuromuscular block (NMB), defined as a post-tetanic-count (PTC) between 0-1, paralyses the abdominal wall muscles and the diaphragm. We hypothesized th...... time, occurrence of wound infection, and wound dehiscence were found. Conclusions: Deep NMB compared with standard NMB resulted in better subjective ratings of surgical conditions during laparotomy.......Background: During laparotomy, surgeons may experience difficult surgical conditions if the patient's abdominal wall or diaphragm is tense. Deep neuromuscular block (NMB), defined as a post-tetanic-count (PTC) between 0-1, paralyses the abdominal wall muscles and the diaphragm. We hypothesized...... that deep NMB (PTC 0-1) would improve subjective ratings of surgical conditions during upper laparotomy as compared with standard NMB. Methods: This was a double blinded, randomized study. A total of 128 patients undergoing elective upper laparotomy were randomized to either continuous deep NMB (infusion...

  7. Impact of video game genre on surgical skills development: a feasibility study.

    Science.gov (United States)

    de Araujo, Thiago Bozzi; Silveira, Filipe Rodrigues; Souza, Dante Lucas Santos; Strey, Yuri Thomé Machado; Flores, Cecilia Dias; Webster, Ronaldo Scholze

    2016-03-01

    The playing of video games (VGs) was previously shown to improve surgical skills. This is the first randomized, controlled study to assess the impact of VG genre on the development of basic surgical skills. Twenty first-year, surgically inexperienced medical students attended a practical course on surgical knots, suturing, and skin-flap technique. Later, they were randomized into four groups: control and/or nongaming (ContG), first-person-shooter game (ShotG), racing game (RaceG), and surgery game (SurgG). All participants had 3 wk of Nintendo Wii training. Surgical and VG performances were assessed by two independent, blinded surgeons who evaluated basal performance (time 0) and performance after 1 wk (time 1) and 3 wk (time 2) of training. The training time of RaceG was longer than that of ShotG and SurgG (P = 0.045). Compared to SurgG and RaceG, VG scores for ShotG improved less between times 0 and 1 (P = 0.010) but more between times 1 and 2 (P = 0.004). Improvement in mean surgical performance scores versus time differed in each VG group (P = 0.011). At time 2, surgical performance scores were significantly higher in ShotG (P = 0.002) and SurgG (P = 0.022) than in ContG. The surgical performance scores of RaceG were not significantly different from the score achieved by ContG (P = 0.279). Different VG genres may differentially impact the development of surgical skills by medical students. More complex games seem to improve performance even if played less. Although further studies are needed, surgery-related VGs with sufficient complexity and playability could be a feasible adjuvant to improving surgical skills. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Surgical training in your hands: organising a skills course.

    Science.gov (United States)

    Burnand, Henry; Mutimer, Jon

    2012-12-01

    The advent of simulated surgical skills courses has brought dynamic changes to the traditional approach to acquiring practical skills in surgery. Teaching is a core part of the surgical profession, and any trainee can be involved in the organisation of skills training courses. This paper outlines the importance of organising surgical skills courses for trainees, and provides a practical guide on how to do so within busy clinical environments. The paper examines how to plan a course, how to design the programme, and provides tips on faculty staff requirements, venue, finance and participants, with additional suggestions for assessment and evaluation. We recommend the organisation of skills courses to any trainee. By following key ground rules, the surgical trainee can enable the acquisition of advanced learning opportunities and the ability to demonstrate valuable organisational skills. © Blackwell Publishing Ltd 2012.

  9. An Instrumented Glove to Assess Manual Dexterity in Simulation-Based Neurosurgical Education

    Directory of Open Access Journals (Sweden)

    Juan Diego Lemos

    2017-04-01

    Full Text Available The traditional neurosurgical apprenticeship scheme includes the assessment of trainee’s manual skills carried out by experienced surgeons. However, the introduction of surgical simulation technology presents a new paradigm where residents can refine surgical techniques on a simulator before putting them into practice in real patients. Unfortunately, in this new scheme, an experienced surgeon will not always be available to evaluate trainee’s performance. For this reason, it is necessary to develop automatic mechanisms to estimate metrics for assessing manual dexterity in a quantitative way. Authors have proposed some hardware-software approaches to evaluate manual dexterity on surgical simulators. This paper presents IGlove, a wearable device that uses inertial sensors embedded on an elastic glove to capture hand movements. Metrics to assess manual dexterity are estimated from sensors signals using data processing and information analysis algorithms. It has been designed to be used with a neurosurgical simulator called Daubara NS Trainer, but can be easily adapted to another benchtop- and manikin-based medical simulators. The system was tested with a sample of 14 volunteers who performed a test that was designed to simultaneously evaluate their fine motor skills and the IGlove’s functionalities. Metrics obtained by each of the participants are presented as results in this work; it is also shown how these metrics are used to automatically evaluate the level of manual dexterity of each volunteer.

  10. Surgical interventions for gastric cancer: a review of systematic reviews.

    Science.gov (United States)

    He, Weiling; Tu, Jian; Huo, Zijun; Li, Yuhuang; Peng, Jintao; Qiu, Zhenwen; Luo, Dandong; Ke, Zunfu; Chen, Xinlin

    2015-01-01

    To evaluate methodological quality and the extent of concordance among meta-analysis and/or systematic reviews on surgical interventions for gastric cancer (GC). A comprehensive search of PubMed, Medline, EMBASE, the Cochrane library and the DARE database was conducted to identify the reviews comparing different surgical interventions for GC prior to April 2014. After applying included criteria, available data were summarized and appraised by the Oxman and Guyatt scale. Fifty six reviews were included. Forty five reviews (80.4%) were well conducted, with scores of adapted Oxman and Guyatt scale ≥ 14. The reviews differed in criteria for avoiding bias and assessing the validity of the primary studies. Many primary studies displayed major methodological flaws, such as randomization, allocation concealment, and dropouts and withdrawals. According to the concordance assessment, laparoscopy-assisted gastrectomy (LAG) was superior to open gastrectomy, and laparoscopy-assisted distal gastrectomy was superior to open distal gastrectomy in short-term outcomes. However, the concordance regarding other surgical interventions, such as D1 vs. D2 lymphadenectomy, and robotic gastrectomy vs. LAG were absent. Systematic reviews on surgical interventions for GC displayed relatively high methodological quality. The improvement of methodological quality and reporting was necessary for primary studies. The superiority of laparoscopic over open surgery was demonstrated. But concordance on other surgical interventions was rare, which needed more well-designed RCTs and systematic reviews.

  11. A framework for the monitoring and evaluation of international surgical initiatives in low- and middle-income countries.

    Science.gov (United States)

    Ibrahim, George M; Cadotte, David W; Bernstein, Mark

    2015-01-01

    An estimated two billion people worldwide lack adequate access to surgical care. To address this humanitarian emergency, an increasing number of international surgical partnerships are emerging between developed and low- and middle-income countries (LMICs). At present, there are no clear indicators that may be used to assess the effectiveness of such initiatives. We conducted an international qualitative study of 31 surgeons from developed and LMICs involved in international partnerships across a variety of subspecialties. Thematic analysis and grounded theory were applied in order to develop a practical framework that may be applied to monitor and evaluate global surgical initiatives. Several themes emerged from the study: (i) there is a large unmet need to establish and maintain prospective databases in LMICs to inform the monitoring and evaluation of international surgical partnerships; (ii) assessment of initiatives must occur longitudinally over the span of several years; (ii) the domains of assessment are contextual and encompass cultural, institutional and regional factors; and (iv) evaluation strategies should explore broader impact within the community and country. Based on thematic analysis within the domains of inputs, outputs and outcomes, a framework for the monitoring and evaluation of international surgical initiatives, the Framework for the Assessment of InteRNational Surgical Success (FAIRNeSS) is proposed. In response to the increasing number of surgical partnerships between developed and LMICs, we propose a framework to monitor and evaluate international surgical initiatives.

  12. Five years experience with a new intraoral maxillary distraction device (RID).

    Science.gov (United States)

    Picard, Arnaud; Diner, Patrick A; Galliani, Eva; Tomat, Catherine; Vazquez, Ma rie Paule; Carls, Friedrich P

    2011-10-01

    Maxillary distraction osteogenesis is well established for the treatment of severe retromaxilla. We report our experience since 2004 of the treatment of 19 patients using a new intraoral maxillary distraction device. Maxillary advancement was successful in all patients with mean advancement of 9.6mm (range 4-17) measured at a point in lateral cephalograms. The new device limited surgical exposure and the amount of materials implanted, and improved control in every phase of the distraction. It was psychologically accepted by patients and was more comfortable than existing devices. Copyright © 2010 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Comparison of two spectral domain optical coherence tomography devices for angle-closure assessment.

    Science.gov (United States)

    Quek, Desmond T; Narayanaswamy, Arun K; Tun, Tin A; Htoon, Hla M; Baskaran, Mani; Perera, Shamira A; Aung, Tin

    2012-08-03

    To compare two spectral domain optical coherence tomography (SD-OCT) devices for the identification of angle structures and the presence of angle closure. This was a prospective comparative study. Consecutive patients underwent gonioscopy and anterior segment imaging using two SD-OCT devices (iVue and Cirrus). Images were evaluated for the ability to detect angle structures such as Schwalbe's line (SL), trabecular meshwork (TM), Schlemm's canal (SC), and scleral spur (SS), and the presence of angle closure. Angle closure was defined as iris contact with the angle wall anterior to the SS on SD-OCT, and nonvisibility of the posterior TM on gonioscopy. Angle closure in an eye was defined as ≥two quadrants of closed angles. AC1 statistic was used to assess the agreement between devices. Of the 69 subjects studied (46.4% male, 84.1% Chinese, mean age 64.0 ± 10.5 years), 40 subjects (40 eyes, 58.0%) had angle closure on gonioscopy. The most identifiable structure on Cirrus SD-OCT was the SS (82.2%) and SL on iVue SD-OCT (74.5%). Angle closure was indeterminable in 14.5% and 50.7% of Cirrus and iVue scans (P gonioscopy was only fair (AC1 = 0.35 and 0.50 for Cirrus and iVue, respectively). It was more difficult to determine angle closure status with iVue compared with Cirrus SD-OCT. There was fair agreement between both devices with gonioscopy for identifying angle closure.

  14. Mobile surgical skills education unit: a new concept in surgical training.

    Science.gov (United States)

    Shaikh, Faisal M; Hseino, Hazem; Hill, Arnold D K; Kavanagh, Eamon; Traynor, Oscar

    2011-08-01

    Basic surgical skills are an integral part of surgical training. Simulation-based surgical training offers an opportunity both to trainees and trainers to learn and teach surgical skills outside the operating room in a nonpatient, nonstressed environment. However, widespread adoption of simulation technology especially in medical education is prohibited by its inherent higher cost, limited space, and interruptions to clinical duties. Mobile skills laboratory has been proposed as a means to address some of these limitations. A new program is designed by the Royal College of Surgeons in Ireland (RCSI), in an approach to teach its postgraduate basic surgical trainees the necessary surgical skills, by making the use of mobile innovative simulation technology in their own hospital settings. In this article, authors describe the program and students response to the mobile surgical skills being delivered in the region of their training hospitals and by their own regional consultant trainers.

  15. Development of the Biopen: a handheld device for surgical printing of adipose stem cells at a chondral wound site

    International Nuclear Information System (INIS)

    O’Connell, Cathal D; Thompson, Fletcher; Beirne, Stephen; Cornock, Rhys; Richards, Christopher J; Chung, Johnson; Gambhir, Sanjeev; Yue, Zhilian; Zhang, Binbin; Taylor, Adam; Quigley, Anita; Kapsa, Robert; Wallace, Gordon G; Di Bella, Claudia; Choong, Peter; Augustine, Cheryl; Bourke, Justin

    2016-01-01

    We present a new approach which aims to translate freeform biofabrication into the surgical field, while staying true to the practical constraints of the operating theatre. Herein we describe the development of a handheld biofabrication tool, dubbed the ‘biopen’, which enables the deposition of living cells and biomaterials in a manual, direct-write fashion. A gelatin–methacrylamide/hyaluronic acid–methacrylate (GelMa/HAMa) hydrogel was printed and UV crosslinked during the deposition process to generate surgically sculpted 3D structures. Custom titanium nozzles were fabricated to allow printing of multiple ink formulations in a collinear (side-by-side) geometry. Independently applied extrusion pressure for both chambers allows for geometric control of the printed structure and for the creation of compositional gradients. In vitro experiments demonstrated that human adipose stem cells maintain high viability (>97%) one week after biopen printing in GelMa/HAMa hydrogels. The biopen described in this study paves the way for the use of 3D bioprinting during the surgical process. The ability to directly control the deposition of regenerative scaffolds with or without the presence of live cells during the surgical process presents an exciting advance not only in the fields of cartilage and bone regeneration but also in other fields where tissue regeneration and replacement are critical. (paper)

  16. Endovascular Treatment of Anastomotic Pseudoaneurysms after Aorto-iliac Surgical Reconstruction

    International Nuclear Information System (INIS)

    Lagana, Domenico; Carrafiello, Gianpaolo; Mangini, Monica; Recaldini, Chiara; Lumia, Domenico; Cuffari, Salvatore; Caronno, Roberto; Castelli, Patrizio; Fugazzola, Carlo

    2007-01-01

    Purpose. To assess the effectiveness of endovascular treatment of anastomotic pseudoaneurysms (APAs) following aorto-iliac surgical reconstruction. Materials. We retrospectively evaluated 21 men who, between July 2000 and March 2006, were observed with 30 APAs, 13 to the proximal anastomosis and 17 to the distal anastomosis. The patients had had previous aorto-iliac reconstructive surgery with a bypass due to aneurysm (15/21) or obstructive disease (6/21). The following devices were used: 12 bifurcated endoprostheses, 2 aorto-monoiliac, 4 aortic extenders, 1 stent-graft leg, and 2 covered stents. Follow-up was performed with CT angiography at 1, 3, and 6 months after the procedure and yearly thereafter. Results. Immediate technical success was 100%. No periprocedural complications occurred. Four patients died during follow-up from causes not related to APA, and 1 (treated for prosthetic-enteric fistula) from sepsis 3 months after the procedure. During a mean follow-up of 19.7 months (range 1-72 months), 2 of 21 occlusions of stent-graft legs occurred 3 and 24 months after the procedure (treated with thrombolysis and percutaneous transluminal angioplasty and femorofemoral bypass, respectively) and 1 type I endoleak. Primary clinical success rate was 81% and secondary clinical success was 91%. Conclusion. Endovascular treatment is a valid alternative to open surgery and can be proposed as the treatment of choice for APAs, especially in patients who are a high surgical risk. Further studies with larger series and longer follow-up are necessary to confirm the long-term effectiveness of this approach

  17. Keep taking the tablets? Assessing the use of tablet devices in learning and teaching activities in the Further Education sector

    OpenAIRE

    Khristin Fabian; Donald MacLean

    2014-01-01

    This article summarises the methodology and outcomes of an interventionist/action research project to assess the benefits, and potential pitfalls, of the use of mobile devices in learning and teaching activities in a Further Education environment. A bank of 15 tablet devices were purchased and prepared for classroom use. Staff members were approached to scope potential activities and uses for the tablet devices. Three departments took part in the research activity: the Language School, Social...

  18. A Novel Clinical-Simulated Suture Education for Basic Surgical Skill: Suture on the Biological Tissue Fixed on Standardized Patient Evaluated with Objective Structured Assessment of Technical Skill (OSATS) Tools.

    Science.gov (United States)

    Shen, Zhanlong; Yang, Fan; Gao, Pengji; Zeng, Li; Jiang, Guanchao; Wang, Shan; Ye, Yingjiang; Zhu, Fengxue

    2017-06-21

    Clinical-simulated training has shown benefit in the education of medical students. However, the role of clinical simulation for surgical basic skill training such as suturing techniques remains unclear. Forty-two medical students were asked to perform specific suturing tasks at three stations with the different settings within four minutes (Station 1: Synthetic suture pad fixed on the bench, Station 2: Synthetic suture pad fixed on the standardized patient, Station 3: Pig skin fixed on the standardized patient); the OSATS (Objective Structured Assessment of Technical Skill) tool was used to evaluate the performance of students. A questionnaire was distributed to the students following the examination. Mean performance score of Station 3 was significant lower than that of Station 1 and 2 in the general performance including tissue handling, time, and motion. The suturing techniques of students at Station 2 and 3 were not as accurate as that at Station 1. Inappropriate tension was applied to the knot at Station 2 compared with Station 1 and 3. On the questionnaire, 93% of students considered clinical-simulated training of basic surgical skills was necessary and may increase their confidence in future clinical work as surgeons; 98% of students thought the assessment was more objective when OSATS tool was used for evaluation. Clinical simulation examination assessed with OSATS might throw a novel light on the education of basic surgical skills and may be worthy of wider adoption in the surgical education of medical students.

  19. SURGICAL TREATMENT FOR BONE METASTASES OF KIDNEY CANCER

    Directory of Open Access Journals (Sweden)

    A. S. Semkov

    2010-01-01

    Full Text Available The data of 67 kidney cancer (KC patients with bone metastases, who had been treated at Moscow City Cancer Hospital Sixty-Two in 2002 to 2009 and had undergone skeletal bone surgery, were retrospectively analyzed. The role of surgical treatment for bone metastases from KC was assessed and the factors influencing the patients survival were determined. Surgical treatment for bone metastases from KC was ascertained to yield satisfactory results in improving the quality of life and increasing survival rates in the patients.

  20. SURGICAL TREATMENT FOR BONE METASTASES OF KIDNEY CANCER

    Directory of Open Access Journals (Sweden)

    A. S. Semkov

    2014-08-01

    Full Text Available The data of 67 kidney cancer (KC patients with bone metastases, who had been treated at Moscow City Cancer Hospital Sixty-Two in 2002 to 2009 and had undergone skeletal bone surgery, were retrospectively analyzed. The role of surgical treatment for bone metastases from KC was assessed and the factors influencing the patients survival were determined. Surgical treatment for bone metastases from KC was ascertained to yield satisfactory results in improving the quality of life and increasing survival rates in the patients.