  1. Impact of multi-detector row computed tomography on the tactics of cardiovascular surgery. From qualitative evaluation to quantitative assessment

    International Nuclear Information System (INIS)

    Imagawa, Hiroshi; Kawachi, Kanji; Takano, Shinji

    2005-01-01

    We assessed the role of multi-detector row computed tomography in cardiovascular surgery. The efficacy of multi-detector row computed tomography was assessed concerning the graft patency of coronary artery bypass, arterial atheromatous degeneration, small vessel imaging, and left ventricular volume measurement. Images were reconstructed using both the volume-rendering and the maximum-intensity-profile methods. Arterial atherosclerotic degeneration was assessed by aortic wall volume and aortic calcification volume. In the assessment of bypass graft patency, multidetector row computed tomography showed a 98% correct positive ratio with sensitivity and specificity of 98% and 100%, respectively. Atheromatous degeneration showed matching results in more than 70% of cases compared with intraoperative findings. More than 92% of arterial branches with diameters of 3 mm or greater were detected by preoperative multi-detector row computed tomography images, though only 6% of branches with diameters of 2 mm or less could be visualized. There was a positive linear correlation between left ventricular volumes determined by multi-detector row computed tomography and those calculated from cine angiography. Multi-detector row computed tomography clearly visualized coronary bypass grafts and aortic arterial branches, providing detailed vascular images. Atheromatous degeneration assessed by multi-detector row computed tomography was equivalent with intraoperative findings in more than 70% of cases. Left ventricular volumes measured by multi-detector row computed tomography correlated closely with those determined by cine-angiography. Multidetector row computed tomography is an efficient and promising modality in cardiovascular surgery. (author)

  2. Lung surgery assisted by multidetector-row computed tomographic simulation

    International Nuclear Information System (INIS)

    Oizumi, Hiroyuki; Endoh, Makoto; Ota, Hiroshi; Takeda, Shinichi; Suzuki, Jun; Fukaya, Ken; Chiba, Masato; Sadahiro, Mitsuaki

    2009-01-01

    We describe the benefits of lung resection simulation using multidetector computed tomography (MDCT). Since 2004, the 1.0-mm slice digital imaging and communications in medicine (DICOM) server has been used for storing data obtained using 64-row MDCT. We observed that an abnormality could not be visualized from the pleural surface in 10 nodules of 18 lesions undergoing wedge lung resection. These 10 nodules were resected through simulation using a three-dimensional (3D) volume-rendering method by considering parameters such as the position, depth, or distance from the interlobar abnormalities, etc., without the need for any marking methods. For lung lobectomy, identification of the branching structures, diameter, and length of the arteries is useful in selecting the procedure for blood vessel treatment. However, in the initial 10 patients of this series, the preoperative identification of 2 small arterial branches was unsuccessful when this method was used. Therefore, it is important to carefully examine the original data in all 3 views, id est (i.e.), axial, sagittal, and coronal views. The visualization of venous branches in affected segments and intersegmental veins has facilitated the preoperative determination of the anatomical intersegmental plane. We divided the cases of thoracoscopic lung segmentectomy into 3 groups (level 1: simple, level 2: intermediate, and level 3: complex) on the basis of the technical complexity. Only level 1 segmentectomies were performed without MDCT simulation. Further, level 2 and 3 segmentectomies could be successfully performed because of the introduction of MDCT simulation in 25 of 35 patients. Thus, this simulation technique may be useful during a thoracoscopic procedure for lung surgery. (author)

  3. Usefulness of multi-detector row Computed Tomography for ...

    African Journals Online (AJOL)

    A 74-year-old female underwent surgical treatment for adenocarcinoma of the pancreatic head. Preoperative multi-detector row computed tomography (MD-CT) demonstrated tumor invasion into the accessory right colic vein and the branch of the middle colic artery (MCA), which was not detected by digital subtraction ...

  4. Multidetector-row computed tomography for prosthetic heart valve dysfunction: is concomitant non-invasive coronary angiography possible before redo-surgery?

    Energy Technology Data Exchange (ETDEWEB)

    Tanis, Wilco [Haga Teaching Hospital, Department of Cardiology, The Hague (Netherlands); Haga Teaching Hospital, The Hague (Netherlands); Sucha, Dominika; Habets, Jesse [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Laufer, Ward; Chamuleau, Steven [University Medical Center Utrecht, Department of Cardiology, Utrecht (Netherlands); Herwerden, Lex.A. van [University Medical Center Utrecht, Department of Cardiothoracic Surgery, Utrecht (Netherlands); Symersky, Petr [Vrije Universiteit, Department of Cardiothoracic Surgery, Amsterdam (Netherlands); Budde, Ricardo P.J. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands)

    2015-06-01

    Retrospective ECG-gated multidetector-row computed tomography (MDCT) is increasingly used for the assessment of prosthetic heart valve (PHV) dysfunction, but is also hampered by PHV-related artefacts/cardiac arrhythmias. Furthermore, it is performed without nitroglycerine or heart rate correction. The purpose was to determine whether MDCT performed before potential redo-PHV surgery is feasible for concomitant coronary artery stenosis assessment and can replace invasive coronary angiography (CAG). PHV patients with CAG and MDCT were identified. Based on medical history, two groups were created: (I) patients with no known coronary artery disease (CAD), (II) patients with known CAD. All images were scored for the presence of significant (>50 %) stenosis. CAG was the reference test. Fifty-one patients were included. In group I (n = 38), MDCT accurately ruled out significant stenosis in 19/38 (50 %) patients, but could not replace CAG in the remaining 19/38 (50 %) patients due to non-diagnostic image quality (n = 16) or significant stenosis (n = 3) detection. In group II (n = 13), MDCT correctly found no patients without significant stenosis, requiring CAG imaging in all. MDCT assessed patency in 16/19 (84 %) grafts and detected a hostile anatomy in two. MDCT performed for PHV dysfunction assessment can replace CAG (100 % accurate) in approximately half of patients without previously known CAD. (orig.)

  5. Multidetector-row computed tomography for prosthetic heart valve dysfunction: is concomitant non-invasive coronary angiography possible before redo-surgery?

    International Nuclear Information System (INIS)

    Tanis, Wilco; Sucha, Dominika; Habets, Jesse; Laufer, Ward; Chamuleau, Steven; Herwerden, Lex.A. van; Symersky, Petr; Budde, Ricardo P.J.

    2015-01-01

    Retrospective ECG-gated multidetector-row computed tomography (MDCT) is increasingly used for the assessment of prosthetic heart valve (PHV) dysfunction, but is also hampered by PHV-related artefacts/cardiac arrhythmias. Furthermore, it is performed without nitroglycerine or heart rate correction. The purpose was to determine whether MDCT performed before potential redo-PHV surgery is feasible for concomitant coronary artery stenosis assessment and can replace invasive coronary angiography (CAG). PHV patients with CAG and MDCT were identified. Based on medical history, two groups were created: (I) patients with no known coronary artery disease (CAD), (II) patients with known CAD. All images were scored for the presence of significant (>50 %) stenosis. CAG was the reference test. Fifty-one patients were included. In group I (n = 38), MDCT accurately ruled out significant stenosis in 19/38 (50 %) patients, but could not replace CAG in the remaining 19/38 (50 %) patients due to non-diagnostic image quality (n = 16) or significant stenosis (n = 3) detection. In group II (n = 13), MDCT correctly found no patients without significant stenosis, requiring CAG imaging in all. MDCT assessed patency in 16/19 (84 %) grafts and detected a hostile anatomy in two. MDCT performed for PHV dysfunction assessment can replace CAG (100 % accurate) in approximately half of patients without previously known CAD. (orig.)

  6. Multi-detector row computed tomography and blunt chest trauma

    International Nuclear Information System (INIS)

    Scaglione, Mariano; Pinto, Antonio; Pedrosa, Ivan; Sparano, Amelia; Romano, Luigia

    2008-01-01

    Blunt chest trauma is a significant source of morbidity and mortality in industrialized countries. The clinical presentation of trauma patients varies widely from one individual to another and ranges from minor reports of pain to shock. Knowledge of the mechanism of injury, the time of injury, estimates of motor vehicle accident velocity and deceleration, and evidence of associated injury to other systems are all salient features to provide for an adequate assessment of chest trauma. Multi-detector row computed tomography (MDCT) scanning and MDCT-angiography are being used more frequently in the diagnosis of patients with chest trauma. The high sensitivity of MDCT has increased the recognized spectrum of injuries. This new technology can be regarded as an extremely valuable adjunct to physical examination to recognize suspected and unsuspected blunt chest trauma

  7. Multidetector-row computed tomography management of acute pulmonary embolism

    International Nuclear Information System (INIS)

    Yasui, Takahiro; Tanabe, Nobuhiro; Terada, Jiro

    2007-01-01

    The purpose of this study was to evaluate the usefulness and safety of multidetector-row computed tomography (MDCT) pulmonary angiography and indirect venography management of acute pulmonary embolism (PE), including indication for inferior vena cava (IVC) filter. Seventy-one consecutive patients who were clinically suspected of PE and underwent 16-slice MDCT pulmonary angiography and indirect venography were enrolled. Management included indication of IVC filter for patients with extensive deep venous thrombosis (DVT) in submassive or massive PE. A right ventricular to left ventricular short-axis diameter by MDCT >1.0 was judged as submassive PE. All patients were followed for 1 year. MDCT identified 50 patients with venous thromboembolism and 47 patients had acute PE: 4 were judged as massive, 14 as submassive, and 29 as non-massive by MDCT; 3 patients had DVT alone and 7 patients had caval or iliac DVT. Only 1 patient with massive PE and DVT near the right atrium died of recurrence. No other patients died of PE. Management based on MDCT pulmonary angiography combined with indirect venography is considered to be safe and reliable in patients with suspected acute PE. (author)

  8. Multi-detector row computed tomography angiography of peripheral arterial disease

    International Nuclear Information System (INIS)

    Kock, Marc C.J.M.; Dijkshoorn, Marcel L.; Pattynama, Peter M.T.; Myriam Hunink, M.G.

    2007-01-01

    With the introduction of multi-detector row computed tomography (MDCT), scan speed and image quality has improved considerably. Since the longitudinal coverage is no longer a limitation, multi-detector row computed tomography angiography (MDCTA) is increasingly used to depict the peripheral arterial runoff. Hence, it is important to know the advantages and limitations of this new non-invasive alternative for the reference test, digital subtraction angiography. Optimization of the acquisition parameters and the contrast delivery is important to achieve a reliable enhancement of the entire arterial runoff in patients with peripheral arterial disease (PAD) using fast CT scanners. The purpose of this review is to discuss the different scanning and injection protocols using 4-, 16-, and 64-detector row CT scanners, to propose effective methods to evaluate and to present large data sets, to discuss its clinical value and major limitations, and to review the literature on the validity, reliability, and cost-effectiveness of multi-detector row CT in the evaluation of PAD. (orig.)

  9. Multidetector row computed tomography evaluation of the micropig kidney as a potential renal donor.

    Science.gov (United States)

    Yoon, Woong; Lee, Min Young; Ryu, Jung Min; Moon, Yong Ju; Lee, Sang Hun; Park, Jae Hong; Yun, Seung Pil; Jang, Min Woo; Park, Sung Su; Han, Ho Jae

    2010-03-01

    Multidetector row computed tomography (MDCT) provides anatomical information about the kidney and other internal organs. Presently, the suitability of 64-channel MDCT to assess the kidney of healthy micropigs was evaluated. Morphological evaluations of the kidney and the major renal vessels of six healthy micropigs were carried out using MDCT, recording kidney volume and the diameter and length of renal arteries and veins. The mean diameters and lengths of the renal artery were 0.44 +/- 0.05 and 4.51 +/- 0.55 cm on the right side and 0.46 +/- 0.06 and 3.36 +/- 0.27 cm on the left side, respectively. The mean diameters and lengths of the renal vein were 1.44 +/- 0.52 and 4.22 +/- 1.29 cm on the right side and 1.38 +/- 0.17 and 5.15 +/- 0.87 cm on the left side, respectively. The mean volume of the right kidney was 79.3 +/- 14.5 mL and of the left kidney was 78.0 +/- 13.9 mL. The data presented in this study suggest that the MDCT offers a noninvasive, rapid, and accurate method for the evaluation of the renal anatomy in living kidney donors. It also provides sufficient information about extra-renal anatomy important for donor surgery and determination of organ suitability.

  10. Prevalence and Characteristics of Myocardial Bridging in Multidetector-Row Computed Tomography Coronary Angiography

    International Nuclear Information System (INIS)

    Carrascosa, Patricia; Martin Lopez, Elba; Capunay, Carlos; Deviggiano, Alejandro; Vallejos, Javier; Carrascosa, Jorge

    2009-01-01

    Background: Myocardial bridging (MB) are congenital defects of the coronary arteries in which a segment of an epicardial artery lies in the myocardium for part of its course. The current gold standard for diagnosing MB is coronary angiography; however other invasive techniques are also useful. Myocardial bridging can also be visualized with the use of novel non-invasive imaging techniques such as multidetector-row computed tomography coronary angiography (MDCT-CA). Objectives: To assess the prevalence and characteristics of myocardial bridging in patients undergoing multidetector-row computed tomography coronary angiography (MDCT-CA). Material and Methods: A total of 452 consecutive patients were evaluated with 16-row and 64-row MDCT-CA due to the presence of abnormal findings in myocardial perfusion image tests, symptoms suggestive of coronary artery disease, and in asymptomatic patients with a family history of coronary artery disease. The presence of MB, their location and characteristics were analyzed. Myocardial bridging were classified as complete and incomplete bridges with respect to continuity of the myocardium over the tunneled segment of the artery involved. Quantitative measurements of vessel diameter during systole and diastole were evaluated. Results: The prevalence of MB was 35.18%; 88 were complete and 71 incomplete. Among complete MB, 6 affected both systole and diastole, 27 presented only systolic compression and 55 showed no compression. Incomplete MB showed absence of arterial compression. Conclusions: Multidetector-row computed tomography coronary angiography detected a higher prevalence of MB in the study population and allowed to classify them and to assess their functional aspects throughout the cardiac cycle. (authors) [es

  11. Multidetector row computed tomography in bowel obstruction. Part 2. Large bowel obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Sinha, R. [Department of Radiology, Glenfield Hospital, Leicester (United Kingdom)]. E-mail: rakesh.sinha@uhl-tr.nhs.uk; Verma, R. [Department of Radiology, Glenfield Hospital, Leicester (United Kingdom)

    2005-10-01

    Large bowel obstruction may present as an emergency as high-grade colonic obstruction and can result in perforation. Perforated large bowel obstruction causes faecal peritonitis, which can result in high morbidity and mortality. Multidetector row computed tomography (MDCT) has the potential of providing an accurate diagnosis of large bowel obstruction. The rapid acquisition of images within one breath-hold reduces misregistration artefacts than can occur in critically ill or uncooperative patients. The following is a review of the various causes of large bowel obstruction with emphasis on important pathogenic factors, CT appearances and the use of multiplanar reformatted images in the diagnostic workup.

  12. Defining Anatomic Variants of the Coronary Artery in Taiwanese Subjects Using 64-Multidetector-Row Computed Tomography

    Directory of Open Access Journals (Sweden)

    Hung-Jung Wang

    2007-10-01

    Full Text Available The newly developed 64-multidetector-row computed tomography (MDCT prompted us to evaluate coronary angiography using this noninvasive method. We reviewed 281 images of MDCT coronary angiography in Taiwanese. The origins of the coronary arteries were identified from the luminal aspect of the aorta. We described them as seen from the aortic sinus looking toward the cardiac ventricle. The sinus facing the left ventricle was designated sinus 1, and that facing the right ventricle was designated sinus 2. Anatomic variants of the coronary artery were divided into five types according to the structure of the left anterior descending artery, right coronary artery, and left circumflex artery. Of the 281 patients, 275 (97.9% had the type I variant in which the right coronary artery originated from sinus 2. MDCT provides advantages in defining anatomic variation and helps in the planning of clinical therapy or surgery.

  13. Multidetector row computed tomography may accurately estimate plaque vulnerability. Does MDCT accurately estimate plaque vulnerability? (Pro)

    International Nuclear Information System (INIS)

    Komatsu, Sei; Imai, Atsuko; Kodama, Kazuhisa

    2011-01-01

    Over the past decade, multidetector row computed tomography (MDCT) has become the most reliable and established of the noninvasive examination techniques for detecting coronary heart disease. Now MDCT is chasing intravascular ultrasound (IVUS) in terms of spatial resolution. Among the components of vulnerable plaque, MDCT may detect lipid-rich plaque, the lipid pool, and calcified spots using computed tomography number. Plaque components are detected by MDCT with high accuracy compared with IVUS and angioscopy when assessing vulnerable plaque. The TWINS study and TOGETHAR trial demonstrated that angioscopic loss of yellow color occurred independently of volumetric plaque change by statin therapy. These 2 studies showed that plaque stabilization and regression reflect independent processes mediated by different mechanisms and time course. Noncalcified plaque and/or low-density plaque was found to be the strongest predictor of cardiac events, regardless of lesion severity, and act as a potential marker of plaque vulnerability. MDCT may be an effective tool for early triage of patients with chest pain who have a normal electrocardiogram (ECG) and cardiac enzymes in the emergency department. MDCT has the potential ability to analyze coronary plaque quantitatively and qualitatively if some problems are resolved. MDCT may become an essential tool for detecting and preventing coronary artery disease in the future. (author)

  14. Complications of myocardial infarction on multidetector-row computed tomography of chest

    International Nuclear Information System (INIS)

    Raj, V.; Karunasaagarar, K.; Rudd, J.H.F.; Screaton, N.; Gopalan, D.

    2010-01-01

    Myocardial infarction (MI) secondary to coronary artery disease remains the leading cause of death in the western world. The advent of early reperfusion therapy has substantially decreased in-hospital mortality and has improved the outcome in survivors of the acute phase of MI. Complications of MI include ischaemic, mechanical, arrhythmic, embolic and inflammatory disturbances. Although some of these complications may be infrequent, their importance is underscored because of the potential ability to correct them with early diagnosis and appropriate treatment. The majority of these complications will be detected on clinical examination and confirmed by echocardiography. Some patients may undergo non-electrocardiogram (ECG)-gated thoracic multidetector-row computed tomography (MDCT) due to non-specific presentation. In this group, it is imperative for the radiologist to be aware of and be confident in diagnosing the complications secondary to MI. This review illustrates the spectrum and imaging features of acute and chronic complications of MI that can be visualized on both ECG-gated cardiac and non-ECG-gated thoracic MDCT.

  15. Complications of myocardial infarction on multidetector-row computed tomography of chest

    Energy Technology Data Exchange (ETDEWEB)

    Raj, V.; Karunasaagarar, K. [Department of Radiology, Papworth and Addenbrookes Hospital, Cambridge (United Kingdom); Rudd, J.H.F. [Division of Cardiovascular Medicine, University of Cambridge, Cambridge (United Kingdom); Screaton, N. [Department of Radiology, Papworth and Addenbrookes Hospital, Cambridge (United Kingdom); Gopalan, D., E-mail: deepa.gopalan@btopenworld.co [Department of Radiology, Papworth and Addenbrookes Hospital, Cambridge (United Kingdom)

    2010-11-15

    Myocardial infarction (MI) secondary to coronary artery disease remains the leading cause of death in the western world. The advent of early reperfusion therapy has substantially decreased in-hospital mortality and has improved the outcome in survivors of the acute phase of MI. Complications of MI include ischaemic, mechanical, arrhythmic, embolic and inflammatory disturbances. Although some of these complications may be infrequent, their importance is underscored because of the potential ability to correct them with early diagnosis and appropriate treatment. The majority of these complications will be detected on clinical examination and confirmed by echocardiography. Some patients may undergo non-electrocardiogram (ECG)-gated thoracic multidetector-row computed tomography (MDCT) due to non-specific presentation. In this group, it is imperative for the radiologist to be aware of and be confident in diagnosing the complications secondary to MI. This review illustrates the spectrum and imaging features of acute and chronic complications of MI that can be visualized on both ECG-gated cardiac and non-ECG-gated thoracic MDCT.

  16. Enhanced multidetector-row computed tomography (MDCT) in the diagnosis of acute appendicitis and its severity

    International Nuclear Information System (INIS)

    Miki, Tesshou; Ogata, Seiji; Uto, Mitsunobu; Nakazono, Toshihiro; Urata, Miyuki; Ishibe, Ryouhei; Shinyama, Shin; Nakajo, Masayuki

    2005-01-01

    The purpose of this study was to examine the accuracy of enhanced multidetector-row computed tomography (MDCT) in diagnosing acute appendicitis and its severity. Contrast-enhanced MD-CT 3.5 mm thick images of 23 control patients (A), and 64 patients with surgically proven acute appendicitis including 8 catarrhal (B), 28 phiegmonous (C), and 28 gangrenous (D) appendicitis patients were respectively analyzed. The number of observed major computed tomography (CT) findings for each patient group were as follows: enlarged (≥6 mm in maximum diameter) appendix (A: 5, B: 8, C: 28, D: 28), enhancement of the appendiceal wall; hyper (A: 3, B: 8, C: 27, D: 20), iso (A: 15, B: 0, C: 1, D: 2), hypo (A-C: 0, D: 4), and patched (A-C: 0, D: 2) enhancement, appendicolith (A, B: 0, C: 7, D: 13), dirty fat sign (A: 3, B: 1, C: 21, D: 28), localized ascites (A: 2, B: 0, C: 2, D: 11), and abscess formation (A-C: 0, D: 5). From the combinations of these findings, we could differentiate acute appendicitis from the control normal appendix with an accuracy of 99% and could diagnose the severity of acute appendicitis with accuracies of 92% for catarrhal appendicitis, 84% for phlegmonous appendicitis, and 92% for gangrenous appendicitis. We could also visually reconstruct the entire forms and positions of the appendices from the successive CT findings because of the high-resolution thin-slice MDCT images. MDCT is highly accurate in the diagnosis of acute appendicitis and its severity. (author)

  17. Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: Comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Pozzi-Mucelli, Fabio; Bruni, Stefano; Doddi, Marco; Calgaro, Antonio; Braini, Massimiliano; Cova, Maria

    2007-01-01

    Purpose: To compare the contribution of 64 channel multidetector row computed tomography angiography (64MDCT-angiography) with digital subtraction angiography (DSA) in the detection of intracranial aneurysms. Methods and materials: Twenty-nine patients (10 males and 19 females, age: 40-84 years; average: 61.9 years) with clinical and imaging findings strongly suggesting the presence of subaracnoid hemorrhage underwent 64MDCT-angiography and DSA with a short interval between the two examinations (less than 12 h-5 days). CT parameters were: 64 mm x 0.5 mm collimation, pitch-0.828 and helical pitch-53. DSA were performed with standard technique (four vessel catheterization) and multiple projections. Axial CT scans as well as maximum intensity projection, volume rendering and multiplanar reformations and angiographic views were independently reviewed by four readers (two for 64MDCT-angiography and two for DSA). Consensus was reached for discordant cases. DSA was considered as the standard of reference. Results: In 29 patients, 28 aneurysms were found (14 patients had 1 aneurysm, 4 patients had 2 aneurysms and 2 patients had 3 aneurysms; in 9 patients no aneurysm were found). 64MDCT-angiography detected 26/28 aneurysms. No false-positive sites were recognized. The sensitivity, specificity, positive and negative predictive values and diagnostic accuracy were, respectively, 92.8, 100, 100, 99.4 and 99.5%. Conclusions: 64MDCT-angiography is helpful in detecting intracranial aneurysms with results similar to those of DSA but with less discomfort and risks for the patients and can be considered for the first line imaging technique. Conventional angiography is still needed in doubtful cases or negative MDCT-angiography associated with a strong clinical suspect

  18. The value of multidetector-row computed tomography for localization of obscure acute gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Wei-Chou [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Tsai, Shih-Hung [Department of Emergency Medicine, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Chang, Wei-Kuo [Division of Gasteroenterology, Department of Internal Medicine, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Liu, Chang-Hsien [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Tung, Ho-Jui [Department of Healthcare Administration, Asia University, Taichung, Taiwan (China); Hsieh, Chung-Bao [Department of Surgery, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Huang, Guo-Shu; Hsu, Hsian-He [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China); Yu, Chih-Yung, E-mail: chougo2002@yahoo.com.tw [Department of Radiology, Tri-Service General Hospital, National Defense Medical Center, Taiwan (China)

    2011-11-15

    Purpose: There are no simple guidelines on when to perform multidetector-row computed tomography (MDCT) for diagnosis of obscure acute gastrointestinal bleeding (AGIB). We used a risk scoring system to evaluate the diagnostic power of MDCT for patients with obscure AGIB. Materials and methods: Ninety-two patients with obscure AGIB who were referred for an MDCT scan after unsuccessful endoscopic treatment at presentation were studied. We recorded clinical data and calculated Blatchford score for each patient. Patients who required transfusion more than 500 mL of blood to maintain the vital signs were classified as high-risk patients. Two radiologists independently reviewed and categorized MDCT signs of obscure AGIB. Discordant findings were resolved by consensus. One-way ANOVA was used to compare clinical data between two groups; kappa statistics were used to estimate agreement on MDCT findings between radiologists. Results: Of the 92 patients, 62 (67.4%) were classified as high-risk patients. Blatchford scores of high-risk patients were significantly greater than those of low-risk patients. Sensitivity for MDCT diagnosing obscure AGIB was 81% in high-risk patients, as compared with 50% in the low-risk. When used in conjunction with selection of the cut-off value of 13 in Blatchford scoring system, the sensitivity and specificity of MDCT were 70.9% and 73.7%, respectively. Contrast extravasation was the most specific sign of AGIB (k = .87), recognition of which would have improved diagnostic accuracy. Conclusions: With the aid of Blatchford scoring system for evaluating the disease severity, MDCT can localize the bleeders of obscure AGIB more efficiently.

  19. Water as a contrast medium: a re-evaluation using the multidetector-row computed tomography.

    Science.gov (United States)

    Makarawo, Tafadzwa P; Negussie, Edsa; Malde, Sachit; Tilak, Jacqueline; Gayagoy, Jennifer; Watson, Jenna; Francis, Faiz; Lincoln, Denis; Jacobs, Michael J

    2013-07-01

    Water as an intraluminal negative contrast medium produces improved image quality with reduced artefact. However, rapid absorption of oral water in the bowel relative to speed and timing of image capturing has limited its clinical application. These findings predate advances in multidetector-row computed tomography (CT). To re-evaluate differences in image quality, we studied image clarity and luminal distention between the same group of patients who received both a pancreas protocol CT (PPCT) that uses oral water and a conventional positive oral contrast scan. We reviewed 66 patients who had previously undergone both a PPCT and an oral contrast abdominal CT. CT images were independently reviewed by two board-certified radiologists who scored degree of hollow viscus distention and visualization of mural detail using a Likert 5-point scale. Results were evaluated by using the Wilcoxon-signed rank test. Student's t test was applied to evaluate the differences in radiation dosage and Spearman's correlational test was used to evaluate interrater correlation between the radiologists. In comparing the mean radiation dosage, there was no statistical difference between the two protocols, and there was good interrater association with ratios of 0.595 and 0.51 achieved for the PPCT and conventional oral scan, respectively. The Wilcoxon signed-rank test showed statistical differences in the stomach (P contrast medium causing better or equal distention in the bowel and better or equal clarity than routine barium contrast. This calls for a need to reconsider the use of water as a contrast medium in clinical practice.

  20. The value of multidetector-row computed tomography for localization of obscure acute gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Chang, Wei-Chou; Tsai, Shih-Hung; Chang, Wei-Kuo; Liu, Chang-Hsien; Tung, Ho-Jui; Hsieh, Chung-Bao; Huang, Guo-Shu; Hsu, Hsian-He; Yu, Chih-Yung

    2011-01-01

    Purpose: There are no simple guidelines on when to perform multidetector-row computed tomography (MDCT) for diagnosis of obscure acute gastrointestinal bleeding (AGIB). We used a risk scoring system to evaluate the diagnostic power of MDCT for patients with obscure AGIB. Materials and methods: Ninety-two patients with obscure AGIB who were referred for an MDCT scan after unsuccessful endoscopic treatment at presentation were studied. We recorded clinical data and calculated Blatchford score for each patient. Patients who required transfusion more than 500 mL of blood to maintain the vital signs were classified as high-risk patients. Two radiologists independently reviewed and categorized MDCT signs of obscure AGIB. Discordant findings were resolved by consensus. One-way ANOVA was used to compare clinical data between two groups; kappa statistics were used to estimate agreement on MDCT findings between radiologists. Results: Of the 92 patients, 62 (67.4%) were classified as high-risk patients. Blatchford scores of high-risk patients were significantly greater than those of low-risk patients. Sensitivity for MDCT diagnosing obscure AGIB was 81% in high-risk patients, as compared with 50% in the low-risk. When used in conjunction with selection of the cut-off value of 13 in Blatchford scoring system, the sensitivity and specificity of MDCT were 70.9% and 73.7%, respectively. Contrast extravasation was the most specific sign of AGIB (k = .87), recognition of which would have improved diagnostic accuracy. Conclusions: With the aid of Blatchford scoring system for evaluating the disease severity, MDCT can localize the bleeders of obscure AGIB more efficiently.

  1. Intensive-care unit lung infections: The role of imaging with special emphasis on multi-detector row computed tomography

    International Nuclear Information System (INIS)

    Romano, Luigia; Pinto, Antonio; Merola, Stefanella; Gagliardi, Nicola; Tortora, Giovanni; Scaglione, Mariano

    2008-01-01

    Nosocomial pneumonia is the most frequent hospital-acquired infection. In mechanically ventilated patients admitted to an intensive-care unit as many as 7-41% may develop pneumonia. The role of imaging is to identify the presence, location and extent of pulmonary infection and the presence of complications. However, the poor resolution of bedside plain film frequently limits the value of radiography as an accurate diagnostic tool. To date, multi-detector row computed tomography with its excellent contrast resolution is the most sensitive modality for evaluating lung parenchyma infections

  2. Multidetector row computed tomography findings from ischemia to infarction of the large bowel

    International Nuclear Information System (INIS)

    Romano, Stefania; Romano, Luigia; Grassi, Roberto

    2007-01-01

    Objective: MDCT is performed as first imaging examination for patients with acute abdomen in most Emergency Departments. Clinical suspicion of ischemic colitis and infarction is related to specific findings, however, differential diagnosis as well as the staging for a confirmed ischemic affection may be critical. The individual signs from ischemia to infarction of large bowel is a captivating topic. In this study, we report our experience of the MDCT assessment of acute colonic disease from vascular mesenteric disorders. Materials and methods: We retrospectively reviewed the MDCT findings of 71 patients admitted to our attention for acute abdomen, with final proven diagnosis of colonic ischemia and/or infarction made by surgery and/or endoscopy. CT-scanning of the abdomen and pelvis was performed after i.v. contrast medium administration, using a multidetector row CT equipment. We correlated the presence of parietal disease, the evidence of mesenteric arterial or venous vessels occlusion, the parietal features as well as others findings, such as free fluid and/or air in peritoneal recess or in retroperitoneum, with the surgical and/or endoscopic findings. Results: Analysis of our data showed a segmental (84%) or complete (16%) involvement of the colon; 57 cases were related to ischemia, 14 to infarction. Inferior mesenteric vessels defect of opacification was noted in 10 cases. Various degree of wall thickening and parietal enhancement, peritoneal fluid, mural or portal-mesenteric pneumatosis were compared to evidence of mesenteric arterial or vein occlusion and to final proven diagnosis. A classification in a multi-stage grading for both decreased of arterial supply or impaired venous drainage disorders was done. Conclusions: A grading scale from ischemia to infarction affecting the large bowel from arterial or venous mesenteric vessels origin has been not previously reported in a series at our knowledge. MDCT findings may support the clinical evaluation of

  3. Anatomical variation of thyroid veins on contrast-enhanced multi-detector row computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Tomita, Hayato, E-mail: m04149@yahoo.co.jp [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Yamada, Takayuki; Murakami, Kenji; Hashimoto, Kazuki; Tazawa, Yoko; Kumano, Reiko [Department of Radiology, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, 1197-1 Yasashicho, Asahi-ku, Yokohama, Kanagawa 241-0811 (Japan); Nakajima, Yasuo [Department of Radiology, St. Marianna University School of Medicine, 2-16-1 Sugao, Miyamae-ku, Kawasaki, Kanagawa 216-8511 (Japan)

    2015-05-15

    Highlights: • This is the first study to demonstrate the anatomy of thyroid veins on contrasted-enhanced MDCT. • Identifying the thyroid vein on MDCT prior to selective venous sampling of parathyroid hormone provides clinical information to interventional radiologist. • Detecting especially the inferior thyroid veins with individual variability in numbers, locations, and lengths may have an effect on SVS for HPT and decrease the difficulty and time of the procedure. - Abstract: Objective: The objective of this study was to clarify the anatomical variation of thyroid veins into the systemic vein using contrast-enhanced multi-detector row computed tomography (MDCT). Design and methods: : The subjects were 80 patients (34 males and 46 females; mean age, 50.1 years; age range, 15–92 years) with neck diseases who underwent MDCT. The number and location of inflow points of the thyroid veins into the systemic vein, and the length from the junction of bilateral brachiocephalic veins to the orifice of inferior thyroid vein were investigated by reviewing the axial and coronal images. Results: All superior thyroid veins were detected. Right and left middle thyroid veins were identified in 39 and 29 patients, respectively. Right inferior thyroid veins, left inferior thyroid veins, and common trunks were detected in 43, 46, and 39 patients, respectively; in five patients, two left thyroid veins were identified. All left inferior thyroid veins and 34 common trunks flowed into the innominate vein, while right ones had some variations in inflow sites. Mean lengths were 3.01 ± 1.30 cm (range, 0.5–6.19) and 2.04 ± 0.91 cm (0.5–4.4) in the left inferior thyroid vein and common trunk, and 1.96 ± 1.05 cm (0.81–4.8) and 1.65 ± 0.69 cm (0.63–2.94) in the right one flowing into the right internal jugular vein and the innominate vein, respectively. Conclusions: The numbers and orifices of thyroid veins were identified at high rates on contrast-enhanced MDCT. This

  4. Rectal cancer staging: Multidetector-row computed tomography diagnostic accuracy in assessment of mesorectal fascia invasion

    Science.gov (United States)

    Ippolito, Davide; Drago, Silvia Girolama; Franzesi, Cammillo Talei; Fior, Davide; Sironi, Sandro

    2016-01-01

    AIM: To assess the diagnostic accuracy of multidetector-row computed tomography (MDCT) as compared with conventional magnetic resonance imaging (MRI), in identifying mesorectal fascia (MRF) invasion in rectal cancer patients. METHODS: Ninety-one patients with biopsy proven rectal adenocarcinoma referred for thoracic and abdominal CT staging were enrolled in this study. The contrast-enhanced MDCT scans were performed on a 256 row scanner (ICT, Philips) with the following acquisition parameters: tube voltage 120 KV, tube current 150-300 mAs. Imaging data were reviewed as axial and as multiplanar reconstructions (MPRs) images along the rectal tumor axis. MRI study, performed on 1.5 T with dedicated phased array multicoil, included multiplanar T2 and axial T1 sequences and diffusion weighted images (DWI). Axial and MPR CT images independently were compared to MRI and MRF involvement was determined. Diagnostic accuracy of both modalities was compared and statistically analyzed. RESULTS: According to MRI, the MRF was involved in 51 patients and not involved in 40 patients. DWI allowed to recognize the tumor as a focal mass with high signal intensity on high b-value images, compared with the signal of the normal adjacent rectal wall or with the lower tissue signal intensity background. The number of patients correctly staged by the native axial CT images was 71 out of 91 (41 with involved MRF; 30 with not involved MRF), while by using the MPR 80 patients were correctly staged (45 with involved MRF; 35 with not involved MRF). Local tumor staging suggested by MDCT agreed with those of MRI, obtaining for CT axial images sensitivity and specificity of 80.4% and 75%, positive predictive value (PPV) 80.4%, negative predictive value (NPV) 75% and accuracy 78%; while performing MPR the sensitivity and specificity increased to 88% and 87.5%, PPV was 90%, NPV 85.36% and accuracy 88%. MPR images showed higher diagnostic accuracy, in terms of MRF involvement, than native axial images

  5. Correct diagnosis of vascular encasement and longitudinal extension of hilar cholangiocarcinoma by four-channel multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Okumoto, Tadayuki; Yamada, Takayuki; Sato, Akihiro

    2009-01-01

    Accurate diagnosis of local invasion of hilar cholangiocarcinomas is challenging due to their small size and the anatomic complexity of the hepatic hilar region. On the other hand, the correct diagnosis of local invasion is essential for assuring the possibility of curative surgery. The purpose of this study was to evaluate the feasibility of four-channel multidetector-row computed tomography (MDCT) in the assessment of vascular and bile duct involvement, by which we could obtain useful information for the surgical management of hilar cholangiocarcinoma. The subjects were 18 patients for whom the extent of tumor invasion was surgically and pathologically confirmed. All patients underwent preoperative multiphasic CT scanning by MDCT. Arterial and portal dominant phases were acquired using a detector configuration of 1.25 mm x 4 mm, and both axial and multiplanar reconstructed images were interpreted. Longitudinal extension was evaluated up to second-order branches. Vascular invasion is considered to be the degree of tumor contiguity to the hepatic arteries and portal vein and was graded by CT. The longitudinal extension was correctly diagnosed in 14 patients (77.8%). Hepatic artery invasion was correctly diagnosed in 17 patients with sensitivity of 100% and specificity of 90%, respectively. Portal vein invasion was correctly diagnosed in 47 of 51 branches with sensitivity and specificity of 92.3% and 90.2%, respectively. Multiplanar reconstructed images contributed to the correct diagnosis for both vascular encasement and longitudinal tumor extension. In conclusion, MDCT is useful in preoperative evaluation of hilar cholangiocarcinoma, especially when combined with multiplanar reconstructed images. (author)

  6. Multidetector-row computed tomography for the preoperative evaluation of axillary nodal status in patients with breast cancer

    International Nuclear Information System (INIS)

    Ogasawara, Yutaka; Doihara, Hiroyoshi; Shiraiwa, Misaki; Ishihara, Setsuko

    2008-01-01

    We evaluated the effectiveness of multidetector-row computed tomography (MD-CT) for detecting axillary lymph nodal status (ALNS) in patients with breast cancer. We reviewed 42 patients with breast cancer. A metastatic lymph node on MD-CT was defined as oval or round, with more than 5 mm on the short axis. We evaluated ALNS preoperatively by both palpation and MD-CT findings and performed sentinel lymph node biopsy (SLNB) and complete axillary lymph node dissection (ALND). For establishing the ALNS, MD-CT showed a sensitivity of 76.9%, a specificity of 96.6%, and an accuracy of 90.5%. On the basis of the MD-CT findings, misdiagnosis was made in 4 of the 42 patients, only one of which was false positive. On the other hand, one patient with a histologically negative sentinel lymph node (SLN) result had metastasis only in a non-SLN. Preoperative MD-CT showed a positive node in this patient. Multidetector-row computed tomography assists in identifying women who require ALND without SLNB, with sufficient positive predictive value. False-negative detection by SLNB could be avoided with careful interpretation of the axillary lymph nodes shown by MD-CT. (author)

  7. Multidetector-row computed tomography coronary angiography. Optimization of image reconstruction phase according to the heart rate

    International Nuclear Information System (INIS)

    Nagatani, Yukihiro; Takahashi, Masashi; Takazakura, Ryutaro; Nitta, Norihisa; Murata, Kiyoshi; Ushio, Noritoshi; Matsuo, Shinro; Yamamoto, Takashi; Horie, Minoru

    2007-01-01

    The purpose of this study was to optimize the image reconstruction phase of multidetector-row computed tomography (MDCT) coronary angiography according to the heart rate is crucial. Scan data were reconstructed for 10 different phases in 58 sequential patients who under went 8-row cardiac MDCT. The obtained images were scored and compared in terms of motion artifacts and visibility of the vessels, and moreover, electrocardiogram (ECG) record-based evaluations were added for clarification of the temporal relationships among these 10 phases. In the cases with lower heart rates ( 65 beats/mm), they were obtained in the late systolic period. As the heart rate increased, the optimal image reconstruction phase changed from mid diastole to late systole. However, it is recommended to try to decrease the heart rate of patients before data acquisition. (author)

  8. Congenital coronary artery anomalies: diagnosis with 64 slice multidetector row computed tomography coronary angiography: A single Centre Study

    International Nuclear Information System (INIS)

    Srnivasan, K.G.; Gaikward, A.; Kannan, B.R.J.; Ritesh, K.; Ushanandini, K.P.

    2008-01-01

    Full text: Retrospective review of the congenital coronary artery (CA) anomalies detected by a 64-slice multidetector row computed tomographic (MDCT) angiography. The type of the anomaly, imaging characteristics, clinical relevance and the superiority of the MDCT over conventional coronary angiography are discussed. Multidetector row computed tomographic coronary angiography was carried out by the usual technique with 70 cc of non-ionic contrast agent and retrospective electrocardiogram gating. The volume data obtained were reconstructed in axial plane, along with volume-rendered three-dimensional reconstruction and virtual angioscopy in selected patients. The images were analysed by a radiologist, experienced in cardiac CT, and an experienced cardiologist. A retrospective review of the records was carried out, and subjects with congenital coronary anomalies were included in the study. Between 15 November 2005 and 27 February 2007, 1495 MDCT coronary angiograms were carried out. Eleven of them were found to have coronary anomalies. Five had absent left main CA. Two had interarterial course of the left main CA artery passing in between the right ventricular outflow tract and the root of aorta. In one patient, there was aberrant origin of right CA from the left aortic sinus with subsequent interarterial course and another one had aberrant origin of circumflex artery from the right aortic sinus. One patient each of congenitally absent circumflex artery and atresia of the right CA were found. Sixty-four slice MDCT coronary angiography provided accurate depiction of anomalous vessel origin and course along with the complex anatomical relation with the adjacent structures. CTcan be considered as a first-line imaging method for delineating coronary arterial anomalies.

  9. Prospective Electrocardiogram-Gated Multidetector Row Computed Tomography Coronary Angiography. Analysis of Quality Image and Radiation Dose

    International Nuclear Information System (INIS)

    Carrascosa, P.; Capunay, C.; Deviggiano, A.; Tajer, C.D.; Vallejos, J.; Goldsmit, A.; Garcia, M.J.

    2009-01-01

    Multidetector row computed tomography coronary angiography (MDCT-CA) has become a useful diagnostic tool for the direct quantification of coronary stenosis, for identifying coronary anomalies and for the assessment of coronary artery bypass grafts. Despite its clinical value has been questioned due to the effective radiation dose (ERD) received by each patient, radiation exposure is similar to other studies. However, different strategies are permanently tested in order to reduce the ERD maintaining adequate and diagnostic image quality. Objectives: To determine the image quality and effective radiation dose (ERD) of prospective electrocardiogram-gated multidetector row computed tomography coronary angiography (PMDCTCA) (the x-ray beam is turned on for only a short portion of diastole) compared to retrospective ECG gating (RMDCTCA) (the x-ray beam is turned on throughout the cardiac cycle) and a preliminary approach of its diagnostic accuracy compared to digital invasive coronary angiography (CA). Material and Methods: Fifty consecutive patients with suspected coronary artery disease and sinus rhythm were evaluated with PMDCT-CA and compared to a control group who underwent RMDCTCA. Image quality was analyzed by two reviewers. Interobserver concordance and ERD were determined. The diagnostic accuracy of PMDCT-CA compared to CA to detect coronary artery stenosis > 50% was assessed in 30 patients. Results: There were no significant differences in the image quality between both groups. Agreement between the reviewers for segment image quality scores was k = 0.92. Mean ERD was 3.5 mSv for PMDCT-CA compared to 9.7 and 12.9 mSv for RMDCT-CA with and without tube current modulation, respectively. Individual analysis including all segments showed that the sensitivity, specificity, positive predictive value and negative predictive value of PMDCT-CA for the detection of coronary stenosis were 94.74%, 81.82%, 90% and 90%, respectively. Conclusion: Our initial experience

  10. Multidetector row computed tomography noninvasively assesses coronary reperfusion after thrombolytic therapy in patients with ST elevation myocardial infarction

    International Nuclear Information System (INIS)

    Shin, Dong-Il; Won, Yoo-Dong; Chang, Kiyuk

    2006-01-01

    The study objective was to assess the efficacy of 16-slice multidetector row computed tomography (MDCT) in estimating residual stenosis and successful reperfusion after thrombolysis in patients with ST-elevation myocardial infarction (STEMI). A total of 31 patients with STEMI underwent MDCT scanning within 6 h (mean 4.6±1.1) after thrombolysis and the results for detection of significant residual stenosis and distal flow of the infarct-related artery were compared with those from conventional coronary angiography (CCAG) performed within 24 h (mean 12.1±5.6) after the MDCT scan. Successful reperfusion was defined as Thrombolysis In Myocardial Infarction flow 2 or 3 on CCAG and full contrast enhancement of the distal artery landmarks on MDCT. A final analysis was performed using 24 patients (312 segments). MDCT had a positive predictive value of 73.3% and a negative predictive value of 95.1% for detecting significant residual stenosis. It accurately estimated 17 of 18 patients (94.4%) with successful reperfusion and 5 of 6 (83.3%) with failed reperfusion on the basis of comparison with CCAG. MDCT demonstrated high accuracy not only for the detecting residual stenosis, but also for assessing successful reperfusion after thrombolytic therapy in patients with STEMI. (author)

  11. Imaging quality and effective radiation dose of prospective ECG-gated axial multidetector row computed tomography coronary angiography

    International Nuclear Information System (INIS)

    Capunay, C.; Carrascosa, P.; Vallejos, J.; Deviggiano, A.; Pollono, P.M.; Garcia, M.J.

    2011-01-01

    Objective. To determine the imaging quality and effective radiation dose (ERD) of prospective ECG-gated multidetector row computed tomography coronary angiography (PMDCTCA) compared to retrospective ECG-gating (RMDCT-CA). Materials and Methods. Forty-five PMDCT-CA scans were retrospectively reviewed for assessing imaging quality and ERD, and compared to 90 RMDCT-CA scans performed with (n=45) and without (n=45) tube current modulation, selected from our database on the basis of similar demographical characteristics. ERD was compared between all three groups. Imaging quality was assessed by two independent observers and compared to the imaging quality of the group of RMDCT-CA scans performed with tube current modulation. The interobserver variability was also determined. Results. There were no significant differences in imaging quality between the two groups. Interobserver variability was k=0.92 (95 % CI: 0.87-0.96). The ERD (mean ± SD) using PMDCT-CA was 2.88 ± 0.37 mSv compared to 10.50 ± 1.15 mSv (p [es

  12. Comparison of the Multidetector-row Computed Tomographic Angiography Axial and Coronal Planes' Usefulness for Detecting Thoracodorsal Artery Perforators

    Science.gov (United States)

    Kim, Jong Gyu

    2012-01-01

    Background During the planning of a thoracodorsal artery perforator (TDAP) free flap, preoperative multidetector-row computed tomographic (MDCT) angiography is valuable for predicting the locations of perforators. However, CT-based perforator mapping of the thoracodorsal artery is not easy because of its small diameter. Thus, we evaluated 1-mm-thick MDCT images in multiple planes to search for reliable perforators accurately. Methods Between July 2010 and October 2011, 19 consecutive patients (13 males, 6 females) who underwent MDCT prior to TDAP free flap operations were enrolled in this study. Patients ranged in age from 10 to 75 years (mean, 39.3 years). MDCT images were acquired at a thickness of 1 mm in the axial, coronal, and sagittal planes. Results The thoracodorsal artery perforators were detected in all 19 cases. The reliable perforators originating from the descending branch were found in 14 cases, of which 6 had transverse branches. The former were well identified in the coronal view, and the latter in the axial view. The location of the most reliable perforators on MDCT images corresponded well with the surgical findings. Conclusions Though MDCT has been widely used in performing the abdominal perforator free flap for detecting reliable perforating vessels, it is not popular in the TDAP free flap. The results of this study suggest that multiple planes of MDCT may increase the probability of detecting the most reliable perforators, along with decreasing the probability of missing available vessels. PMID:22872839

  13. Multidetector-row computed tomography of thoracic aortic anomalies in dogs and cats: Patent ductus arteriosus and vascular rings

    Directory of Open Access Journals (Sweden)

    Nolte Ingo

    2011-09-01

    Full Text Available Abstract Background Diagnosis of extracardiac intrathoracic vascular anomalies is of clinical importance, but remains challenging. Traditional imaging modalities, such as radiography, echocardiography, and angiography, are inherently limited by the difficulties of a 2-dimensional approach to a 3-dimensional object. We postulated that accurate characterization of malformations of the aorta would benefit from 3-dimensional assessment. Therefore, multidetector-row computed tomography (MDCT was chosen as a 3-dimensional, new, and noninvasive imaging technique. The purpose of this study was to evaluate patients with 2 common diseases of the intrathoracic aorta, either patent ductus arteriosus or vascular ring anomaly, by contrast-enhanced 64-row computed tomography. Results Electrocardiography (ECG-gated and thoracic nongated MDCT images were reviewed in identified cases of either a patent ductus arteriosus or vascular ring anomaly. Ductal size and morphology were determined in 6 dogs that underwent ECG-gated MDCT. Vascular ring anomalies were characterized in 7 dogs and 3 cats by ECG-gated MDCT or by a nongated thoracic standard protocol. Cardiac ECG-gated MDCT clearly displayed the morphology, length, and caliber of the patent ductus arteriosus in 6 affected dogs. Persistent right aortic arch was identified in 10 animals, 8 of which showed a coexisting aberrant left subclavian artery. A mild dilation of the proximal portion of the aberrant subclavian artery near its origin of the aorta was present in 4 dogs, and a diverticulum analogous to the human Kommerell's diverticulum was present in 2 cats. Conclusions Contrast-enhanced MDCT imaging of thoracic anomalies gives valuable information about the exact aortic arch configuration. Furthermore, MDCT was able to characterize the vascular branching patterns in dogs and cats with a persistent right aortic arch and the morphology and size of the patent ductus arteriosus in affected dogs. This additional

  14. Accessory Renal Artery Stenosis and Hypertension: Are These Correlated? Evaluation Using Multidetector-Row Computed Tomographic Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Saba, L.; Sanfilippo, R.; Montisci, R.; Conti, M.; Mallarini, G. (Dept. of Imaging Science and Dept. of Vascular Surgery, Policlinico Universitario, Cagliari (Italy))

    2008-04-15

    Background: Renal artery stenosis may produce hypertension, and this condition is referred to as renovascular hypertension (RVH). Purpose: To evaluate, by using multidetector-row spiral computed tomographic angiography (MDCTA), whether a relationship between accessory renal artery stenosis and hypertension may be hypothesized. Material and Methods: 214 patients (142 males, 72 females; mean age 66 years) who had previously undergone an MDCTA to study the abdominal vasculature were retrospectively studied. Patients with renal artery stenosis (RAS) were excluded from this analysis. The patients were studied by means of a four-detector-row CT, and scans were obtained after intravenous bolus administration of 110-140 ml of a nonionic contrast material with a 3-6 ml/s flow rate. As a second step, by means of statistical analysis, hypertension data were compared with findings of accessory artery stenosis. Two radiologists first independently reviewed the MDCTA images and then, in case of disagreement, in consensus. Interobserver agreement was calculated for all measurements. Results: The overall number of detected accessory renal arteries was 74 in 56 of the 214 patients. Accessory renal artery stenosis was detected in 21 of the 56 patients. There was a difference in the prevalence of hypertension between patients with (n = 21) and without (n = 35) accessory renal artery stenosis (P = 0.0187). Interobserver agreement was good (kappa value 0.733). Conclusion: Any statistical association between the presence of accessory renal artery stenosis and hypertension could not be disclosed. However, accessory renal artery stenosis, detected by MDCTA, is an important pathological sign that the radiologist has to assess in the light of its possible association with hypertension

  15. Assessment of temporal resolution of multi-detector row computed tomography in helical acquisition mode using the impulse method.

    Science.gov (United States)

    Ichikawa, Katsuhiro; Hara, Takanori; Urikura, Atsushi; Takata, Tadanori; Ohashi, Kazuya

    2015-06-01

    The purpose of this study was to propose a method for assessing the temporal resolution (TR) of multi-detector row computed tomography (CT) (MDCT) in the helical acquisition mode using temporal impulse signals generated by a metal ball passing through the acquisition plane. An 11-mm diameter metal ball was shot along the central axis at approximately 5 m/s during a helical acquisition, and the temporal sensitivity profile (TSP) was measured from the streak image intensities in the reconstructed helical CT images. To assess the validity, we compared the measured and theoretical TSPs for the 4-channel modes of two MDCT systems. A 64-channel MDCT system was used to compare TSPs and image quality of a motion phantom for the pitch factors P of 0.6, 0.8, 1.0 and 1.2 with a rotation time R of 0.5 s, and for two R/P combinations of 0.5/1.2 and 0.33/0.8. Moreover, the temporal transfer functions (TFs) were calculated from the obtained TSPs. The measured and theoretical TSPs showed perfect agreement. The TSP narrowed with an increase in the pitch factor. The image sharpness of the 0.33/0.8 combination was inferior to that of the 0.5/1.2 combination, despite their almost identical full width at tenth maximum values. The temporal TFs quantitatively confirmed these differences. The TSP results demonstrated that the TR in the helical acquisition mode significantly depended on the pitch factor as well as the rotation time, and the pitch factor and reconstruction algorithm affected the TSP shape. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  16. Influence of gating phase selection on the image quality of coronary arteries in multidetector row computed tomography

    International Nuclear Information System (INIS)

    Laskowska, K.; Marzec, M.; Serafin, Z.; Nawrocka, E.; Lasek, W.; WWisniewska-Szmyt, J.; Kubica, J.

    2005-01-01

    Motion artifacts caused by cardiac movement disturb the imaging of coronary arteries with multidetector-row spiral computed tomography. The aim of this study was to determine the phase of the heart rate which provides the best quality of coronary artery imaging in retrospective ECG-gated CT. Although 75% is usually the best reconstruction phase, the optimal phase should be established individually for the patient, artery, segment, and type of tomograph for the best imaging quality. Forty-five cardiac CT angiograms of 26 patients were retrospectively evaluated. The examinations were performed with a 4-detector-row tomograph. ECG-gated retrospective reconstructions were relatively delayed at 0%, 12.5%, 25%, 37.5%, 50%, 62.5%, 75%, and 87.5% of the cardiac cycle. Selected coronary arteries of the highest diagnostic quality were estimated in the eight phases of the cardiac cycle. Only arteries of very high image quality were selected for analysis: left coronary artery trunks (44 cases, incl. 37 stented), anterior interventricular branches (36, incl. 3 stented), circumflex branches (16), right coronary rtery branches (23), and posterior interventricular branches (4). The reconstruction phase had a statistically significant impact on the quality of imaging (p < 0.0003). Depending on the case, optimal imaging was noted in various phases, except in the 12.5 % phase. The 75% phase appeared to be the best of all those examined (p < 0.05), both in the group of arteries without stents (p < 0.0006) and in those stented (p < 0.05). In some cases of repeated examinations the best phases differed within the same patient. (author)

  17. Usefulness and safety of propranolol injection into vein for acquisition of coronary multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Sekine, Takako; Kodama, Takahide; Kondo, Takeshi

    2010-01-01

    A low heart rate (HR), associated with a prolonged slow filling phase (SF), is necessary to obtain a high quality coronary CT at a low radiation dose with conventional 64 multidetector-row computed tomography (MDCT). The purpose of our study was to confirm the safety of injecting propranolol (2-10 mg) into the vein for lowering heart rate in patients requiring MDCT and to document the effect of the drug on HR, PQ and SF. Of 1290 consecutive patients who were initially considered for enrollment in the coronary MDCT study, 40 patients with atrial fibrillations, 3 with atrial flutters, and 13 with artificial pacemakers were excluded. Of the remaining 1234 patients (M/F=714/520), 331 had already taken an oral beta-blocker before the CT examination, and were included in the study. In patients with no contraindications, propranolol was aggressively injected (2-10 mg) into the vein to reduce the HR. In patients not taking an oral beta blocker, 2 mg propranolol reduced the HR by -10±5 bpm and 10 mg, by -20±7 bpm. However, in patients taking an oral beta-blocker, the decrease in HR by propranolol was minimal (2 mg, -6±4 bpm; 10 mg, -10±6 bpm). Propranolol significantly prolonged the PQ interval (from 169±27 to 179±29 ms, P<0.0001), and SF (from 125±69 to 264±79 ms, P<0.0001). Adverse effects of propranolol injection were observed in only 3 [2 mild hypotension and 1 paroxysmal atrial fibrillation (recovered to sinus rhythm by DC counter shock)] of 3212 patients. All 3 patients became stable after 1 or 2 hours of rest and could return home. Propranolol injection was a relatively safe and useful method to reduce HR and prolong SF, necessary for obtaining high quality coronary MDCT with a low radiation dose. (author)

  18. Multidetector-row computed tomography for evaluating the branching angle of the celiac artery: a descriptive study

    International Nuclear Information System (INIS)

    Tokue, Hiroyuki; Tokue, Azusa; Tsushima, Yoshito

    2012-01-01

    We performed this study in order to investigate the shape of the origin of the celiac artery in maximum intensity projection (MIP) using routine 64 multidetector-row computed tomography (MDCT) data in order to plan for the implantation of an intra-arterial hepatic port system. A total of 1,104 patients with hepatocellular carcinoma were assessed with MDCT. In the definition of the branching angle, the anterior side of the abdominal aorta was considered the baseline, and the cranial and caudal sides were designated as 0 and 180 degrees, respectively. The angles between 0 and 90 degrees and between 90 and 180 degrees from the cranial side were considered upward and downward, respectively, and the branching angle of the celiac artery was classified every 30 degrees. The subclavian arterial route was used for the implantation of an intra-arterial hepatic port system in patients with branching angles of 150 degrees or more (sharp downward). The median branching angle was (median ± standard deviation) 135 ± 23 (range, 51–174) degrees. The branching was upward in 77 patients (7%) and downward in 1,027 patients (93%). The branching was downward with an angle of 120 to150 degrees in most patients (n = 613). The branching was sharply downward with an angle of 150 degrees or more in 177 patients (16%). A total of 10 patients were referred for interventional placement of an intra-arterial hepatic port system. The subclavian arterial route was used for implantation of an intra-arterial hepatic port system in 2 patients with sharp downward branching. The branching angle of the celiac artery can be easily determined by the preparation of MIP images from routine MDCT data. MIP may provide useful information for the selection of the catheter insertion route in order to avoid a sharp branching angle of the celiac artery

  19. Accuracy of multidetector row computed tomography for the diagnosis of acute bowel ischemia in a non-selected study population

    International Nuclear Information System (INIS)

    Wiesner, Walter; Hauser, Andreas; Steinbrich, Wolfgang

    2004-01-01

    The diagnostic accuracy of multidetector row computed tomography for the prospective diagnosis of acute bowel ischemia in the daily clinical routine was analyzed. Two hundred ninety-one consecutive patients with an acute or subacute abdomen, examined by MDCT over a time period of 5 months, were included in the study. All original CT diagnoses made during the daily routine by radiological generalists were compared to the final diagnoses made by using all available medical information from endoscopies, surgical interventions, autopsies and follow-up. Finally, all CT examinations of patients with an initial CT diagnosis or a final diagnosis of bowel ischemia were reread by a radiologist specialized in abdominal imaging in order to analyze the CT findings and the reasons for initially false negative or false positive CT readings. Twenty-four patients out of 291 (8.2%) had acute bowel ischemia. The age of affected patients ranged from 50 to 94 years (mean age: 75.7 years). Eleven patients were male, and 13 female. Reasons for acute bowel ischemia were: arterio-occlusive (n=11), non-occlusive (n=5), strangulation (n=2), over-distension (n=3) and radiation (n=3). The prospective sensitivity, specificity, PPV and NPV of MDCT for the diagnosis of acute bowel ischemia in the daily routine were 79.17, 98.51, 90.48 and 98.15%. MDCT reaches a similarly high sensitivity in diagnosing acute bowel as angiography. Furthermore, it has the advantage of being helpful in most of its clinical differential diagnoses and of being less invasive with the consecutive possibility of being used earlier in the diagnostic process with all the resulting positive effects on the patients prognosis. Therefore, nowadays MDCT should probably be used as the first step imaging modality of choice in patients with suspected acute bowel ischemia. (orig.)

  20. Multidetector-row computed tomography for evaluating the branching angle of the celiac artery: a descriptive study

    Directory of Open Access Journals (Sweden)

    Tokue Hiroyuki

    2012-12-01

    Full Text Available Abstract Background We performed this study in order to investigate the shape of the origin of the celiac artery in maximum intensity projection (MIP using routine 64 multidetector-row computed tomography (MDCT data in order to plan for the implantation of an intra-arterial hepatic port system. Methods A total of 1,104 patients with hepatocellular carcinoma were assessed with MDCT. In the definition of the branching angle, the anterior side of the abdominal aorta was considered the baseline, and the cranial and caudal sides were designated as 0 and 180 degrees, respectively. The angles between 0 and 90 degrees and between 90 and 180 degrees from the cranial side were considered upward and downward, respectively, and the branching angle of the celiac artery was classified every 30 degrees. The subclavian arterial route was used for the implantation of an intra-arterial hepatic port system in patients with branching angles of 150 degrees or more (sharp downward. Results The median branching angle was (median ± standard deviation 135 ± 23 (range, 51–174 degrees. The branching was upward in 77 patients (7% and downward in 1,027 patients (93%. The branching was downward with an angle of 120 to150 degrees in most patients (n = 613. The branching was sharply downward with an angle of 150 degrees or more in 177 patients (16%. A total of 10 patients were referred for interventional placement of an intra-arterial hepatic port system. The subclavian arterial route was used for implantation of an intra-arterial hepatic port system in 2 patients with sharp downward branching. Conclusions The branching angle of the celiac artery can be easily determined by the preparation of MIP images from routine MDCT data. MIP may provide useful information for the selection of the catheter insertion route in order to avoid a sharp branching angle of the celiac artery.

  1. Accessory Renal Artery Stenosis and Hypertension: Are These Correlated? Evaluation Using Multidetector-Row Computed Tomographic Angiography

    International Nuclear Information System (INIS)

    Saba, L.; Sanfilippo, R.; Montisci, R.; Conti, M.; Mallarini, G.

    2008-01-01

    Background: Renal artery stenosis may produce hypertension, and this condition is referred to as renovascular hypertension (RVH). Purpose: To evaluate, by using multidetector-row spiral computed tomographic angiography (MDCTA), whether a relationship between accessory renal artery stenosis and hypertension may be hypothesized. Material and Methods: 214 patients (142 males, 72 females; mean age 66 years) who had previously undergone an MDCTA to study the abdominal vasculature were retrospectively studied. Patients with renal artery stenosis (RAS) were excluded from this analysis. The patients were studied by means of a four-detector-row CT, and scans were obtained after intravenous bolus administration of 110-140 ml of a nonionic contrast material with a 3-6 ml/s flow rate. As a second step, by means of statistical analysis, hypertension data were compared with findings of accessory artery stenosis. Two radiologists first independently reviewed the MDCTA images and then, in case of disagreement, in consensus. Interobserver agreement was calculated for all measurements. Results: The overall number of detected accessory renal arteries was 74 in 56 of the 214 patients. Accessory renal artery stenosis was detected in 21 of the 56 patients. There was a difference in the prevalence of hypertension between patients with (n = 21) and without (n = 35) accessory renal artery stenosis (P = 0.0187). Interobserver agreement was good (kappa value 0.733). Conclusion: Any statistical association between the presence of accessory renal artery stenosis and hypertension could not be disclosed. However, accessory renal artery stenosis, detected by MDCTA, is an important pathological sign that the radiologist has to assess in the light of its possible association with hypertension

  2. Multidetector row computed tomography and ultrasound characteristics of caudal vena cava duplication in dogs.

    Science.gov (United States)

    Bertolini, Giovanna; Diana, Alessia; Cipone, Mario; Drigo, Michele; Caldin, Marco

    2014-01-01

    Caudal vena cava duplication has been rarely reported in small animals. The purpose of this retrospective study was to describe characteristics of duplicated caudal vena cava in a large group of dogs. Computed tomography (CT) and ultrasound databases from two hospitals were searched for canine reports having the diagnosis "double caudal vena cava." One observer reviewed CT images for 71 dogs and two observers reviewed ultrasound images for 21 dogs. In all CT cases, the duplication comprised two vessels that were bilaterally symmetrical and approximately the same calibre (similar to Type I complete duplication in humans). In all ultrasound cases, the duplicated caudal vena cava appeared as a distinct vessel running on the left side of the abdominal segment of the descending aorta and extending from the left common iliac vein to the left renal vein. The prevalence of caudal vena cava duplication was 0.46% for canine ultrasound studies and 2.08% for canine CT studies performed at these hospitals. Median body weight for affected dogs was significantly lower than that of unaffected dogs (P dogs, caudal vena cava duplication should be differentiated from other vascular anomalies when planning surgeries and for avoiding misdiagnoses. © 2014 American College of Veterinary Radiology.

  3. Multidetector-row helical computed tomography in the evaluation of cervical spine disorders; Tomografia computadorizada multislice no diagnostico das afeccoes da coluna cervical

    Energy Technology Data Exchange (ETDEWEB)

    Rosemberg, Laercio Alberto; Almeida, Milena Oliveira; Rios, Adriana Martins; Garbaccio, Viviane Ladeira; Kim, Nelson Ji Tae; Daniel, Mauro Miguel; Funari, Marcelo Buarque de Gusmao [Hospital Israelita Albert Einstein, Sao Paulo, SP (Brazil). Dept. de Imagem]. E-mail: laercio@einstein.br

    2003-07-01

    Multidetector-row computed tomography (MRCT) has advantages in comparison to conventional helical computed tomography, such as reduction of study time, lower radiation doses, fewer metallic artifacts and high quality multiplanar reformatting and three dimensional reconstructions. We reviewed 150 cervical spine examinations and selected the most illustrative cases including congenital anomalies, degenerative lesions, spinal infections, neoplasms, traumatic injuries and postoperative abnormalities. The quality of multiplanar reformatting and volume reconstructions of the MRCT made the detection and evaluation of most of cases with complex anatomy easier and more precise. (author)

  4. Renal replacement lipomatosis: multidetector-row computed tomography findings in one case

    International Nuclear Information System (INIS)

    Calisir, C.; Can, C.; Kebapci, M.

    2007-01-01

    Replacement lipomatosis of the kidney is the result of severe atrophy of the renal parenchyma often caused by chronic calculus disease with secondary marked benign proliferation of fibrofatty tissue replacing atrophied renal parenchyma. Different radiological modalities have been used to illustrate this entity, with magnetic resonance imaging, ultrasound, intravenous pyelogram, and computed tomography (CT) used most frequently. We report multidedector CT (MDCT) findings of replacement lipomatosis in a 50-year-old woman. We think that it accurately provides a complete one-step diagnostic workup and appropriate pre-surgical planning for patients for whom there is a suspicion of replacement lipomatosis

  5. Advanced Gastric Cancer and Perfusion Imaging Using a Multidetector Row Computed Tomography: Correlation with Prognostic Determinants

    International Nuclear Information System (INIS)

    Zhang, Huan; Pan, Zilai; Du, Lianjun; Yan, Chao; Ding, Bei; Song, Qi; Ling, Huawei; Chen, Kemin

    2008-01-01

    Objective : To investigate the relationship between the perfusion CT features and the clinicopathologically determined prognostic factors in advanced gastric cancer cases. Materials and Methods : A perfusion CT was performed on 31 patients with gastric cancer one week before surgery using a 16-channel multi-detector CT (MDCT) instrument. The data were analyzed with commercially available software to calculate tumor blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface (PS). The microvessel density (MVD), was evaluated by immunohistochemical staining of the surgical specimens with anti-CD34. All of the findings were analyzed prospectively and correlated with the clinicopathological findings, which included histological grading, presence of lymph node metastasis, serosal involvement, distant metastasis, tumor, node, metastasis (TNM) staging, and MVD. The statistical analyses used included the Student's t-test and the Spearman rank correlation were performed in SPSS 11.5. Result : The mean perfusion values and MVD for tumors were as follows: BF (48.14+/-16.46 ml/100 g/min), BV (6.70+/-2.95 ml/100 g), MTT (11.75+/-4.02 s), PS (14.17+/-5.23 ml/100 g/min) and MVD (41.7+/-11.53). Moreover, a significant difference in the PS values was found between patients with or without lymphatic involvement (p = 0.038), as well as with different histological grades (p 0.04) and TNM stagings (p = 0.026). However, BF, BV, MTT, and MVD of gastric cancer revealed no significant relationship with the clinicopathological findings described above (p > 0.05). Conclusion : The perfusion CT values of the permeable surface could serve as a useful prognostic indicator in patients with advanced gastric cancer

  6. Advanced Gastric Cancer and Perfusion Imaging Using a Multidetector Row Computed Tomography: Correlation with Prognostic Determinants

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Huan; Pan, Zilai; Du, Lianjun; Yan, Chao; Ding, Bei; Song, Qi; Ling, Huawei; Chen, Kemin [Jiaotong University, Jiaotong (China)

    2008-04-15

    Objective : To investigate the relationship between the perfusion CT features and the clinicopathologically determined prognostic factors in advanced gastric cancer cases. Materials and Methods : A perfusion CT was performed on 31 patients with gastric cancer one week before surgery using a 16-channel multi-detector CT (MDCT) instrument. The data were analyzed with commercially available software to calculate tumor blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface (PS). The microvessel density (MVD), was evaluated by immunohistochemical staining of the surgical specimens with anti-CD34. All of the findings were analyzed prospectively and correlated with the clinicopathological findings, which included histological grading, presence of lymph node metastasis, serosal involvement, distant metastasis, tumor, node, metastasis (TNM) staging, and MVD. The statistical analyses used included the Student's t-test and the Spearman rank correlation were performed in SPSS 11.5. Result : The mean perfusion values and MVD for tumors were as follows: BF (48.14+/-16.46 ml/100 g/min), BV (6.70+/-2.95 ml/100 g), MTT (11.75+/-4.02 s), PS (14.17+/-5.23 ml/100 g/min) and MVD (41.7+/-11.53). Moreover, a significant difference in the PS values was found between patients with or without lymphatic involvement (p = 0.038), as well as with different histological grades (p 0.04) and TNM stagings (p = 0.026). However, BF, BV, MTT, and MVD of gastric cancer revealed no significant relationship with the clinicopathological findings described above (p > 0.05). Conclusion : The perfusion CT values of the permeable surface could serve as a useful prognostic indicator in patients with advanced gastric cancer.

  7. Comparison of the multidetector-row computed tomography findings of IgG4-related sclerosing cholangitis and extrahepatic cholangiocarcinoma

    International Nuclear Information System (INIS)

    Yata, M.; Suzuki, K.; Furuhashi, N.; Kawakami, K.; Kawai, Y.; Naganawa, S.

    2016-01-01

    Aim: To compare the multidetector-row computed tomography (MDCT) findings of IgG4-related sclerosing cholangitis (IgG4-SC) and extrahepatic cholangiocarcinoma (EH-CCA). Materials and methods: Two radiologists who had no knowledge of the patients' clinical information retrospectively evaluated the CT findings of patients with IgG4-SC (n=33) and EH-CCA (n=39) on a consensus basis. Another radiologist measured the biliary lesions. IgG4-SC was diagnosed using the Japan Biliary Association criteria (2012) or the Mayo Clinic's HISORt criteria. EH-CCA was diagnosed based on surgical findings. Results: Compared with EH-CCA, IgG4-SC exhibited the following findings significantly more frequently: (a) wall thickening alone, (b) concentric wall thickening, (c) smooth inner margins, (d) homogeneous attenuation in the arterial phase, (e) a lesion involving the intrapancreatic bile duct, (f) smooth outer margins, (g) fully visible lumen, (h) a funnel-shaped proximal bile duct, (i) skip lesions, and (j) abnormal pancreatic findings. Conversely, (k) dual-layered attenuation in all phases was significantly more common in EH-CCA. The specificity values of parameters (e–k) were >80%. Regarding dimensions, (l) the biliary lesions were longer in IgG4-SC than in EH-CCA. (m) The diameters of the dilated proximal common bile duct and (n) the dilated proximal intrahepatic bile duct were smaller in IgG4-SC than in EH-CCA. Conclusion: A number of CT findings are useful for differentiating between IgG4-SC and EH-CCA. CT findings (e–k) are particularly useful for this purpose. - Highlights: • Some CT findings are useful for differentiating between IgG4-SC and EH-CCA. • Homogeneous attenuation in all phases was more common in IgG4-SC than in EH-CCA. • Abnormal pancreatic findings showed high sensitivity and specificity values. • Dual-layered attenuation in all phases was more common in EH-CCA than in IgG4-SC.

  8. Effect of computer-aided detection as a second reader in multidetector-row CT colonography

    International Nuclear Information System (INIS)

    Mang, Thomas; Peloschek, Philipp; Plank, Christina; Maier, Andrea; Weber, Michael; Herold, Christian; Schima, Wolfgang; Graser, Anno; Bogoni, Luca

    2007-01-01

    Our purpose was to assess the effect of computer-aided detection (CAD) on lesion detection as a second reader in computed tomographic colonography, and to compare the influence of CAD on the performance of readers with different levels of expertise. Fifty-two CT colonography patient data-sets (37 patients: 55 endoscopically confirmed polyps ≥0.5 cm, seven cancers; 15 patients: no abnormalities) were retrospectively reviewed by four radiologists (two expert, two nonexpert). After primary data evaluation, a second reading augmented with findings of CAD (polyp-enhanced view, Siemens) was performed. Sensitivities and reading time were calculated for each reader without CAD and supported by CAD findings. The sensitivity of expert readers was 91% each, and of nonexpert readers, 76% and 75%, respectively, for polyp detection. CAD increased the sensitivity of expert readers to 96% (P = 0.25) and 93% (P = 1), and that of nonexpert readers to 91% (P = 0.008) and 95% (P = 0.001), respectively. All four readers diagnosed 100% of cancers, but CAD alone only 43%. CAD increased reading time by 2.1 min (mean). CAD as a second reader significantly improves sensitivity for polyp detection in a high disease prevalence population for nonexpert readers. CAD causes a modest increase in reading time. CAD is of limited value in the detection of cancer. (orig.)

  9. Normal mediastinal and hilar lymph nodes in children on multi-detector row chest computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Jong, Pim A. de; Nievelstein, Rutger-Jan A. [University Medical Center Utrecht and Wilhelmina Children' s Hospital, Department of Radiology, Utrecht (Netherlands)

    2012-02-15

    To study normal mediastinal and hilar lymph nodes on multi-detector chest computed tomography (CT). A cohort of 120 children aged 1-17 years underwent emergency CT, including the chest, after high-energy trauma. Axial 5-mm reconstructions were evaluated for lymph nodes at hilar and various mediastinal levels and the short-axis diameters were measured. At least one lymph node was found in 115 (96%) children, with subcarinal (69%), lower paratracheal (64%) and hilar (60%) nodes being most common. Up to 10 years of age most lymph nodes were smaller than or equal to 7 mm. In older children lymph nodes measuring up to 10-mm-short-axis diameter were found. Lymph nodes were rare along the mammary vessels, at lower oesophageal and at prevascular and posterior mediastinal levels in children. Mediastinal and hilar lymph nodes are more common than previously thought, probably because of increased detection by modern multi-detector CT. Lymph node location and age have to be taken into account when evaluating lymph nodes in the paediatric chest. (orig.)

  10. Normal mediastinal and hilar lymph nodes in children on multi-detector row chest computed tomography

    International Nuclear Information System (INIS)

    Jong, Pim A. de; Nievelstein, Rutger-Jan A.

    2012-01-01

    To study normal mediastinal and hilar lymph nodes on multi-detector chest computed tomography (CT). A cohort of 120 children aged 1-17 years underwent emergency CT, including the chest, after high-energy trauma. Axial 5-mm reconstructions were evaluated for lymph nodes at hilar and various mediastinal levels and the short-axis diameters were measured. At least one lymph node was found in 115 (96%) children, with subcarinal (69%), lower paratracheal (64%) and hilar (60%) nodes being most common. Up to 10 years of age most lymph nodes were smaller than or equal to 7 mm. In older children lymph nodes measuring up to 10-mm-short-axis diameter were found. Lymph nodes were rare along the mammary vessels, at lower oesophageal and at prevascular and posterior mediastinal levels in children. Mediastinal and hilar lymph nodes are more common than previously thought, probably because of increased detection by modern multi-detector CT. Lymph node location and age have to be taken into account when evaluating lymph nodes in the paediatric chest. (orig.)

  11. Noninvasive imaging of coronary arteries: current and future role of multidetector row computer tomography

    International Nuclear Information System (INIS)

    Nedevska, M.; Stoinova, V.

    2006-01-01

    Full text: This review will present the current and future role of cardiac computer tomography (CCT), and particular multidetector CCT, for imaging of atherosclerotic pathologic changes of the coronary arteries. Atherosclerosis and its cardio-vascular complications represent one of the major issues of public health in industrial countries. Different imaging modalities, including invasive coronarography, have been aimed to the diagnosis of the disease, when it provokes symptomatic decrease of the blood flow. In spite of development of surgical and percutaneous methods for coronary revascularization, coronary artery disease remains the major cause of death in North America and Europe. This demonstrates the need of novel, complementary diagnostic strategies, aimed to identify asymptomatic stages as the basis of pharmacological interventions. Noninvasive coronary angiography with multidetector CT allows both assessment of luminal stenosis and subclinical disease of arterial wall. Large trails are missing now to understand and present what will be the role of this technology in the comprehensive assessment of patients, suspected of having CAD. Based on experience and current potentials we will describe how tomographic coronary imaging may eventually supplement traditional angiographic techniques in understanding the patterns of atherosclerotic CAD development

  12. Limitations of airway dimension measurement on images obtained using multi-detector row computed tomography.

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Oguma

    Full Text Available OBJECTIVES: (a To assess the effects of computed tomography (CT scanners, scanning conditions, airway size, and phantom composition on airway dimension measurement and (b to investigate the limitations of accurate quantitative assessment of small airways using CT images. METHODS: An airway phantom, which was constructed using various types of material and with various tube sizes, was scanned using four CT scanner types under different conditions to calculate airway dimensions, luminal area (Ai, and the wall area percentage (WA%. To investigate the limitations of accurate airway dimension measurement, we then developed a second airway phantom with a thinner tube wall, and compared the clinical CT images of healthy subjects with the phantom images scanned using the same CT scanner. The study using clinical CT images was approved by the local ethics committee, and written informed consent was obtained from all subjects. Data were statistically analyzed using one-way ANOVA. RESULTS: Errors noted in airway dimension measurement were greater in the tube of small inner radius made of material with a high CT density and on images reconstructed by body algorithm (p<0.001, and there was some variation in error among CT scanners under different fields of view. Airway wall thickness had the maximum effect on the accuracy of measurements with all CT scanners under all scanning conditions, and the magnitude of errors for WA% and Ai varied depending on wall thickness when airways of <1.0-mm wall thickness were measured. CONCLUSIONS: The parameters of airway dimensions measured were affected by airway size, reconstruction algorithm, composition of the airway phantom, and CT scanner types. In dimension measurement of small airways with wall thickness of <1.0 mm, the accuracy of measurement according to quantitative CT parameters can decrease as the walls become thinner.

  13. Clinico-statistical study of preoperative examination for the dental implant using multi-detector row computed tomography

    International Nuclear Information System (INIS)

    Sekiya, Keiko; Mori, Shintaro; Sekiya, Kotaro

    2008-01-01

    In April 2006, a new affiliated hospital opened at Nihon University School of Dentistry at Matsudo, and the latest model was introduced into the department of radiology. CT examinations for preoperative dental implant going on 64 multi-detector row CT, the number of cases has increased. CT examination is useful for preoperative dental implant, and many studies of concerning clinical studies using CT images have been reported. The purpose of this study was to the clinico-statistical studies of preoperative CT examinations for dental implant at our radiology department using 64 multi-detector row CT. The subjects consisted of 5174 regions in 1312 cases of preoperative CT examinations, between April 2006 and December 2007. CT machine used was the Aquilion TM 64 (Toshiba Medical Systems, Japan), and the workstation used was the ZIOSTATION (ZIOSOFT, Japan). All of CT examinations were performed the position of implant placement and disease examined from CT findings. The following results were obtained: The 1312 cases consisted of 426 males and 886 females. Patient age ranged from 16 yrs to 86 yrs old, the average age were 55.5 yrs old. Six hundred and seventy four cases were ordered at another private dental office not our hospital, and 638 cases were ordered at our hospital. The numbers of implant placement were on the average of 3.9, and the rate got higher with age. The lesions which detected by preoperative CT examination were maxillary sinusitis, periodontitis, ectopic calcification, and mucous retention cyst. (author)

  14. Focal Stenosis in Right Upper Lobe Bronchus in a Recurrently Wheezing Child Sequentially Studied by Multidetector-row Spiral Computed Tomography and Scintigraphy

    Directory of Open Access Journals (Sweden)

    I-Chen Chen

    2009-12-01

    Full Text Available Lower respiratory tract infections associated with wheezing are not uncommon in infants and young children. Among the wheezing-associated disorders, allergic etiologies are more commonly encountered than anatomic anomalies. We present a 3-year-old girl with a sudden attack of asthmatic symptoms including dyspnea, cyanosis and diffuse wheezing. Based on a history of choking, and atelectasis in the right upper lobe detected by chest films, flexible tracheobronchoscopy was arranged and incidentally detected a stenotic orifice in the right upper lobe bronchus. Multidetector-row spiral computed tomography and pulmonary scintigraphy subsequently also disclosed the focal stenosis. She suffered from recurrent wheezing, pneumonia and lung atelectasis during 1 year of follow-up. We emphasize the diagnosis, clinical course and management of focal stenosis in the right upper lobe bronchus.

  15. Usefulness of multidetector-row computed tomography (MD-CT) for diagnosis and evaluation of cardiovascular anomalies in infants

    International Nuclear Information System (INIS)

    Kani, Hiroyuki; Narabayashi, Isamu; Tanikake, Masato; Matsuki, Mitsuru; Uesugi, Yasuo

    2005-01-01

    We examined the effectiveness of multidetector-row CT (MD-CT) in the diagnosis and evaluation of cardiovascular anomalies in infants. MD-CT was performed 34 times on 21 patients with cardiovascular anomalies. We performed three evaluations: 1) The assessment of the specificity of MD-CT in detecting the morphological features of cardiovascular anomalies. 2) The diameters of aortae with coronary artery (CoA), and the diameters of pulmonary artery, measured by using MD-CT were compared with those by angiography. 3) The amount of exposure to radiation was measured. 1) MD-CT can detect CoA, pulmonary arteriovenous anomalies among extracardiac anomalies in all the patients. The diagnostic accuracy for intracardiac anomalies was poor as only six of the 15 anomalies could be accurately diagnosed. 2) The diameters of aortae and pulmonary artery obtained using MD-CT showed a good correlation with those obtained using arteriography (r=0.97, 0.95). 3) The average dose-length product was 269.2 mGy·cm. And the average effective dose was 5.1 mSv. MD-CT is not suitable for the evaluation of intracardiac anomalies, but is extremely effective in the evaluation of extracardiac major vascular anomalies. On the basis of the amount of information and noninvasive nature, MD-CT should be used first before angiography. (author)

  16. Evaluation of left ventricular function and volume with multidetector-row computed tomography. Comparison with electrocardiogram-gated single photon emission computed tomography

    International Nuclear Information System (INIS)

    Suzuki, Takeya; Yamashina, Shohei; Nanjou, Shuji; Yamazaki, Junichi

    2007-01-01

    This study compared left ventricular systolic function and volume determined by multidetector-row computed tomography (MDCT) and electrocardiogram-gated single photon emission computed tomography (G-SPECT) Thirty-seven patients with coronary artery disease and non-cardiovascular disease underwent MDCT. In this study, left ventricular ejection fraction (EF), left ventricular end-diastolic volume (EDV) and left ventricular end-systolic volume (ESV) were calculated using only two-phase imaging with MDCT. Left ventricular function and volume were compared using measurements from G-SPECT. We conducted MDCT and G-SPECT virtually simultaneously. Both the EF and ESV evaluated by MDCT closely correlated with G-SPECT (r=0.763, P 65 bpm) during MDCT significantly influenced the difference in EF calculated from MDCT and G-SPECT (P<0.05). Left ventricular function can be measured with MDCT as well as G-SPECT. However, a heart rate over 65 bpm during MDCT negatively affects the EF correlation between MDCT and G-SPECT. (author)

  17. Study on children patient dose in single-detector and multi-detector row helical computed tomography

    International Nuclear Information System (INIS)

    Lu Heqing; Zhu Guoying; Zhuo Weihai; Liu Haikuan; Guo Changyi

    2008-01-01

    Objective: To study and evaluate the radiation dose of children patient in single-detector and multi-detector row helical CT scan. Methods: The head and body CT dose index of 21 CT scanners were tested. Then the values of CTDI w , CTDI vol and DLP were calculated combining with the parameters of routine head and chest scan for children of 0-1 year old group, 5 years old group, 10 years old group and adults. The effective doses of children of every age group and adults in routine head and chest scan were subsequently estimated from effective dose per DLP by age and the calculated values of DLP. Results: CTDI per mAs is greater in the head than that in the body. In head routine scan, the effective doses of 0-1 year old group,5 years old group and 10 year old group were 2.2, 1.3 and 1.1 mSv, respectively. In chest routine scan, the effective doses of 0-1 year old group,5 years old group and 10 years old group were 5.3, 3.1 and 3.4 mSv, respectively. Effective doses to children per mAs are equally 1.8 times higher than corresponding values for adults. The CTDI vol , DLP and effective dose to children in head routine scan for MDCT were greater those that for single-detector CT and dual- detector CT. The CTDI vol , DLP and effective dose to children in chest routine scan for MDCT and dual-detector row CT were smaller than that for single-detector row CT. Conclusions: Children me more radiation risk in CT examination as compared with adults. So we should strictly abide by justification of children CT examination, and optimize the parameters of CT scan rationally in order to reduce the radiation dose to children patient as much as possible. (authors)

  18. Computer-assisted lung nodule volumetry from multi-detector row CT: Influence of image reconstruction parameters

    International Nuclear Information System (INIS)

    Honda, Osamu; Sumikawa, Hiromitsu; Johkoh, Takeshi; Tomiyama, Noriyuki; Mihara, Naoki; Inoue, Atsuo; Tsubamoto, Mitsuko; Natsag, Javzandulam; Hamada, Seiki; Nakamura, Hironobu

    2007-01-01

    Purpose: To investigate differences in volumetric measurement of pulmonary nodules caused by changing the reconstruction parameters for multi-detector row CT. Materials and methods: Thirty-nine pulmonary nodules less than 2 cm in diameter were examined by multi-slice CT. All nodules were solid, and located in the peripheral part of the lungs. The resultant 48 parameters images were reconstructed by changing slice thickness (1.25, 2.5, 3.75, or 5 mm), field of view (FOV: 10, 20, or 30 cm), algorithm (high-spatial frequency algorithm or low-spatial frequency algorithm) and reconstruction interval (reconstruction with 50% overlapping of the reconstructed slices or non-overlapping reconstruction). Volumetric measurements were calculated using commercially available software. The differences between nodule volumes were analyzed by the Kruskal-Wallis test and the Wilcoxon Signed-Ranks test. Results: The diameter of the nodules was 8.7 ± 2.7 mm on average, ranging from 4.3 to 16.4 mm. Pulmonary nodule volume did not change significantly with changes in slice thickness or FOV (p > 0.05), but was significantly larger with the high-spatial frequency algorithm than the low-spatial frequency algorithm (p < 0.05), except for one reconstruction parameter. The volumes determined by non-overlapping reconstruction were significantly larger than those of overlapping reconstruction (p < 0.05), except for a 1.25 mm thickness with 10 cm FOV with the high-spatial frequency algorithm, and 5 mm thickness. The maximum difference in measured volume was 16% on average between the 1.25 mm slice thickness/10 cm FOV/high-spatial frequency algorithm parameters and overlapping reconstruction. Conclusion: Volumetric measurements of pulmonary nodules differ with changes in the reconstruction parameters, with a tendency toward larger volumes in high-spatial frequency algorithm and non-overlapping reconstruction compared to the low-spatial frequency algorithm and overlapping reconstruction

  19. Multidetector row computed tomography of acute pancreatitis: Utility of single portal phase CT scan in short-term follow up

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Yongwonn [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Park, Hee Sun, E-mail: heesun.park@gmail.com [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of); Kim, Young Jun; Jung, Sung Il; Jeon, Hae Jeong [Department of Radiology, Konkuk University Medical Center, 4-12, Hwayang-dong, Gwangjin-gu, Seoul 143-729 (Korea, Republic of)

    2012-08-15

    Objective: The purpose of this study is to evaluate the question of whether nonenhanced CT or contrast enhanced portal phase CT can replace multiphasic pancreas protocol CT in short term monitoring in patients with acute pancreatitis. Materials and methods: This retrospective study was approved by the Institutional Review Board. From April 2006 to May 2010, a total of 52 patients having acute pancreatitis who underwent initial dual phase multidetector row CT (unenhanced, arterial, and portal phase) at admission and a short term (within 30 days) follow up dual phase CT (mean interval 10.3 days, range 3-28 days) were included. Two abdominal radiologists performed an independent review of three sets of follow up CT images (nonenhanced scan, single portal phase scan, and dual phase scan). Interpretation of each image set was done with at least 2-week interval. Radiologists evaluated severity of acute pancreatitis with regard to pancreatic inflammation, pancreatic necrosis, and extrapancreatic complication, based on the modified CT severity index. Scores of each image set were compared using a paired t-test and interobserver agreement was evaluated using intraclass correlation coefficient statistics. Results: Mean scores of sum of CT severity index on nonenhanced scan, portal phase scan, and dual phase scan were 5.7, 6.6, and 6.5 for radiologist 1, and 5.0, 5.6, and 5.8 for radiologist 2, respectively. In both radiologists, contrast enhanced scan (portal phase scan and dual phase scan) showed significantly higher severity score compared with that of unenhanced scan (P < 0.05), while portal phase and dual phase scan showed no significant difference each other. The trend was similar regarding pancreatic inflammation and extrapancreatic complications, in which contrast enhanced scans showed significantly higher score compared with those of unenhanced scan, while no significant difference was observed between portal phase scan and dual phase scan. In pancreatic necrosis

  20. Multi-detector row computed tomographic evaluation of a rare type of complete vascular ring: Double aortic arch with atretic left arch distal to the origin of left subclavian artery

    Energy Technology Data Exchange (ETDEWEB)

    Hung, Ying Ying; Fu, Ching Yun; Wei, Hao Ji; Tsai, I Chen; Chen, Clayton Chi Chang [Taichung Veterans General Hospital, Taichung (China)

    2013-10-15

    Double aortic arch with an atretic left arch distal to the origin of left subclavian artery was diagnosed with multi-detector row computed tomography (MDCT) in two children with dysphagia. This rare type of complete vascular ring is clinically important because it may be confused with right aortic arch in mirror imaging. Anatomic details of this rare type of complete vascular ring demonstrated on MDCT facilitated appropriate surgical treatment.

  1. Contrast enhancement in multidetector-row computed tomography (MDCT) of the abdomen: intraindividual comparison of contrast media containing 300 mg versus 370 mg iodine per ml

    International Nuclear Information System (INIS)

    Behrendt, F.F.; Mahnken, A.H.; Keil, S.; Das, M.; Hohl, C.; Guenther, R.W.; Muehlenbruch, G.; Bauer, D.; Seidensticker, P.; Jost, E.; Wildberger, J.E.

    2008-01-01

    The purpose of this study was to intraindividually evaluate the difference in intraluminal vessel and parenchyma contrast enhancement of two different iodine concentrations in multidetector-row computed tomography (MDCT) of the abdomen. Eighty-three patients underwent baseline and follow-up MDCT-scanning (Somatom Sensation 16; Siemens, Forchheim, Germany) of the abdomen using contrast media containing 370 mg iodine/ml (protocol A; Ultravist 370, Bayer Schering Pharma, Berlin, Germany) and 300 mg iodine/ml (protocol B; Ultravist 300). The total iodine load (37 g iodine) and the iodine delivery rate (1.29 g iodine/s) were identical for both protocols. Contrast enhancement in the portal venous phase was measured in the abdominal aorta, inferior vena cava, portal vein, liver, spleen, pancreas and kidney. Mean attenuation values were compared using paired t-test. Intraindividual comparison revealed no statistically significant differences of the mean attenuation values between protocols A and B for all anatomic sites: abdominal aorta, inferior vena cava, portal vein, liver, spleen, pancreas and kidney (all P > 0.05). Given an injection protocol with constant total iodine load and constant iodine delivery rate, the iodine concentration of contrast media does not significantly influence abdominal contrast enhancement in the portal venous phase. (orig.)

  2. Sixteen multidetector row computed tomography of pulmonary veins: 3-months' follow-up after treatment of paroxysmal atrial fibrillation with cryothermal ablation

    International Nuclear Information System (INIS)

    Maksimovic, Ruzica; Cademartiri, Filippo; Pattynama, Peter M.T.; Scholten, Marcoen F.; Jordaens, Luc J.

    2005-01-01

    The aim of the study was to assess pulmonary veins (PVs) for the presence of stenosis 3 months after cryothermal ablation (CA) with a new method of electrical isolation of PVs using contrast-enhanced 16 multidetector row computed tomography (MDCT). Twenty four patients with symptomatic atrial fibrillation underwent CA in 46 PVs. MDCT of PVs was performed before the treatment and after 3-months' follow-up. Following cryoablation, 13/24 (54%) patients showed clinical improvement and had reduced attacks of atrial fibrillation. The dimensions of the treated PVs remained unchanged: the coronal ostial diameter was 19.1±2.4 preprocedural versus 18.6±2.4 mm at follow-up, p>0.05; the ratio of the coronal and axial diameters at the ostium was 1.2±0.2 versus 1.2±0.1, p>0.05, respectively, and the coronal diameter of the proximal 10 mm was 17.1±2.5 mm versus 16.5±2.2 mm, p>0.05, respectively. CA is a promising technique for electrical isolation of PVs that has not been associated with stenosis at the orifice and the proximal 10 mm of the PVs after 3-months' follow-up. MDCT is a noninvasive, fast and comfortable method for assessment of PVs in a three-dimensional manner prior to ablative treatment and during the follow-up. (orig.)

  3. Sixteen multidetector row computed tomography of pulmonary veins: 3-months' follow-up after treatment of paroxysmal atrial fibrillation with cryothermal ablation

    Energy Technology Data Exchange (ETDEWEB)

    Maksimovic, Ruzica; Cademartiri, Filippo; Pattynama, Peter M.T. [Erasmus Medical Center, Department of Radiology, Rotterdam (Netherlands); Scholten, Marcoen F.; Jordaens, Luc J. [Erasmus Medical Center, Department of Cardiology, Rotterdam (Netherlands)

    2005-06-01

    The aim of the study was to assess pulmonary veins (PVs) for the presence of stenosis 3 months after cryothermal ablation (CA) with a new method of electrical isolation of PVs using contrast-enhanced 16 multidetector row computed tomography (MDCT). Twenty four patients with symptomatic atrial fibrillation underwent CA in 46 PVs. MDCT of PVs was performed before the treatment and after 3-months' follow-up. Following cryoablation, 13/24 (54%) patients showed clinical improvement and had reduced attacks of atrial fibrillation. The dimensions of the treated PVs remained unchanged: the coronal ostial diameter was 19.1{+-}2.4 preprocedural versus 18.6{+-}2.4 mm at follow-up, p>0.05; the ratio of the coronal and axial diameters at the ostium was 1.2{+-}0.2 versus 1.2{+-}0.1, p>0.05, respectively, and the coronal diameter of the proximal 10 mm was 17.1{+-}2.5 mm versus 16.5{+-}2.2 mm, p>0.05, respectively. CA is a promising technique for electrical isolation of PVs that has not been associated with stenosis at the orifice and the proximal 10 mm of the PVs after 3-months' follow-up. MDCT is a noninvasive, fast and comfortable method for assessment of PVs in a three-dimensional manner prior to ablative treatment and during the follow-up. (orig.)

  4. Efficacy of double arterial phase dynamic magnetic resonance imaging with the sensitivity encoding technique versus dynamic multidetector-row helical computed tomography for detecting hypervascular hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kumano, Seishi; Okada, Masahiro; Murakami, Takamichi; Uemura, Masahiko; Haraikawa, Toyoaki; Hirata, Masaaki; Kikuchi, Keiichi; Mochizuki, Teruhito; Kim, Tonsok

    2009-01-01

    The aim of this study was to evaluate the efficacy of double arterial phase dynamic magnetic resonance imaging (MRI) with the sensitivity encoding technique (SENSE dynamic MRI) for detection of hypervascular hepatocellular carcinoma (HCC) in comparison with double arterial phase dynamic multidetector-row helical computed tomography (dynamic MDCT). A total of 28 patients with 66 hypervascular HCCs underwent both double arterial SENSE dynamic MRI and dynamic MDCT. The diagnosis of HCC was based on surgical resection (n=7), biopsy (n=10), or a combination of CT during arterial portography (CTAP), CT during hepatic arteriography (CTA), and/or the 6-month follow-up CT (n=49). Based on alternative-free response receiving operating characteristic (ROC) analysis, the diagnostic performance for detecting HCC was compared between double arterial phase SENSE dynamic MRI and double arterial phase dynamic MDCT. The mean sensitivity, positive predictive value, and mean A Z values for hypervascular HCCs were 72%, 80%, and 0.79, respectively, for SENSE dynamic MRI and 66%, 92%, and 0.78, respectively, for dynamic MDCT. The mean sensitivity for double arterial phase SENSE dynamic MRI was higher than that for double arterial phase dynamic MDCT, but the difference was not statistically significant. Double arterial phase SENSE dynamic MRI is as valuable as double arterial phase dynamic MDCT for detecting hypervascular HCCs. (author)

  5. Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography

    International Nuclear Information System (INIS)

    Heuschmid, Martin; Rothfuss, Julia K.; Fenchel, Michael; Stauder, Norbert; Kuettner, Axel; Miller, Stephan; Claussen, Claus D.; Kopp, Andreas F.; Schroeder, Stephen; Burgstahler, Christof; Franow, Andreas; Kuzo, Ronald S.

    2006-01-01

    To assess functional parameters using multidetector-row computed tomography (MDCT) and echocardiography and to compare the results with magnetic resonance imaging (MRI). End-diastolic-volume (EDV), end-systolic-volume (ESV), stroke-volume (SV), ejection-fraction (EF), and myocardial mass (MM) were calculated based on CT data sets from 52 patients. Echocardiography was performed in 24 of the 52 patients. The results from MDCT and echocardiography were compared with MRI. A strong correlation between MDCT and MRI (r=0.66-0.90) was found for all parameters. Echocardiography revealed a low or moderate correlation (0.05-0.59). Compared to MRI the average differences with MDCT were for EDV 15.1 ml, ESV 10.6 ml, SV 4.5 ml, EF 1.8%, and MM 8.2 g, for EDV determined by echocardiography 36.2 ml, ESV 6.8 ml, and EF 13.9%. Bland-Altman analysis revealed acceptable limits of agreement between MRI and MDCT. MDCT enables reliable quantification of left ventricular function. Echocardiography was found to have only a moderate agreement of functional parameters with MRI. (orig.)

  6. Evaluation of prosthetic valve obstruction on electrocardiographically gated multidetector-row computed tomography--identification of subprosthetic pannus in the aortic position.

    Science.gov (United States)

    Ueda, Tomohiro; Teshima, Hideki; Fukunaga, Shuji; Aoyagi, Shigeaki; Tanaka, Hiroyuki

    2013-01-01

    This study was performed to evaluate the diagnostic role of electrocardiographically gated multidetector-row computed tomography (MDCT) for prosthetic valve obstruction (PVO) in the aortic position. Between 2002 and 2006, 9 patients were diagnosed with PVO of an aortic bileaflet mechanical valve based on echocardiographic and cineradiographic criteria. These 9 patients were examined using MDCT before replacement of the mechanical valve, and intraoperative findings were compared to morphologic periprosthetic abnormalities observed on MDCT. CT attenuation (Hounsfield units; HU) of the periprosthetic abnormalities was measured to investigate the underlying cause of the PVO. MDCT showed subprosthetic masses extending beyond the prosthetic ring into the orifice of the valve. At reoperation, presence of subprosthetic pannus was confirmed in all of the 9 patients, but no periprosthetic thrombus was found. The mean CT attenuation of the subprosthetic pannus was 170 HU, and it was significantly greater than that obtained from the interventricular septum (108 HU; Ppannus causing PVO and the mean CT attenuation of subprosthetic pannus is significantly higher than that of the interventricular septum on MDCT.

  7. Quantitative assessment of lung volumes using multi-detector row computed tomography (MDCT) in patients with chronic obstructive pulmonary disease (COPD)

    International Nuclear Information System (INIS)

    Lee, Sang Min; Hur, Jin; Kim, Tae Hoon; Kim, Sang Jin; Kim, Hyung Jung

    2008-01-01

    To evaluate the clinical value of the multi-detector row computed tomography (MDCT) in the quantitative assessment of lung volumes and to assess the relationship between the MDCT results and disease severity as determined by a pulmonary function test (PFT) in Chronic Obstructive Pulmonary Disease (COPD) patients. We performed a PFT and MDCT on 39 COPD patients. Using the GOLD classifications, we divided the patients into three groups according to disease severity; stage I (mild, n = 10), stage II (moderate, n = 15), and stage III (severe, n = 14). Using the pulmo-CT software program, we measured the proportion of lung volumes with attenuation values below -910 and -950 HU. The mean FEV1 (% of predicted) and FEV1/FVC was 82.2 ± 2% and 66.2 ± 3% in stage I, 53.5 ± 11% and 52 ± 6% in stage II, and 32.3 ± 7% and 44.2% ± 13% in stage III, respectively. Differences in lung volume percentage at each of the thresholds (-910 and -950 HU) among the 3 stages were statistically significant (ρ < 0.01, ρ < 0.01) and correlated well with the FEV1 and FEV1/FVC (r = -0.803, r -0.766, r = -0.817, and r = -0.795, respectively). The volumetric measurement obtained by MDCT provides an accurate means of quantifying pulmonary emphysema

  8. Influence of the Quantity of Aortic Valve Calcium on the Agreement Between Automated 3-Dimensional Transesophageal Echocardiography and Multidetector Row Computed Tomography for Aortic Annulus Sizing.

    Science.gov (United States)

    Podlesnikar, Tomaz; Prihadi, Edgard A; van Rosendael, Philippe J; Vollema, E Mara; van der Kley, Frank; de Weger, Arend; Ajmone Marsan, Nina; Naji, Franjo; Fras, Zlatko; Bax, Jeroen J; Delgado, Victoria

    2018-01-01

    Accurate aortic annulus sizing is key for selection of appropriate transcatheter aortic valve implantation (TAVI) prosthesis size. The present study compared novel automated 3-dimensional (3D) transesophageal echocardiography (TEE) software and multidetector row computed tomography (MDCT) for aortic annulus sizing and investigated the influence of the quantity of aortic valve calcium (AVC) on the selection of TAVI prosthesis size. A total of 83 patients with severe aortic stenosis undergoing TAVI were evaluated. Maximal and minimal aortic annulus diameter, perimeter, and area were measured. AVC was assessed with computed tomography. The low and high AVC burden groups were defined according to the median AVC score. Overall, 3D TEE measurements slightly underestimated the aortic annulus dimensions as compared with MDCT (mean differences between maximum, minimum diameter, perimeter, and area: -1.7 mm, 0.5 mm, -2.7 mm, and -13 mm 2 , respectively). The agreement between 3D TEE and MDCT on aortic annulus dimensions was superior among patients with low AVC burden (AVC burden (≥3,025 arbitrary units). The interobserver variability was excellent for both methods. 3D TEE and MDCT led to the same prosthesis size selection in 88%, 95%, and 81% of patients in the total population, the low, and the high AVC burden group, respectively. In conclusion, the novel automated 3D TEE imaging software allows accurate and highly reproducible measurements of the aortic annulus dimensions and shows excellent agreement with MDCT to determine the TAVI prosthesis size, particularly in patients with low AVC burden. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  9. Threshold-dependent variability of coronary artery calcification measurements - implications for contrast-enhanced multi-detector row-computed tomography

    International Nuclear Information System (INIS)

    Moselewski, Fabian; Ferencik, Maros; Achenbach, Stephan; Abbara, Suhny; Cury, Ricardo C.; Booth, Sarah L.; Jang, Ik-Kyung; Brady, Thomas J.; Hoffmann, Udo

    2006-01-01

    Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM]) at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 ± 68.7 HU versus 295 ± 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT

  10. Whole tumour first-pass perfusion using a low-dose method with 64-section multidetector row computed tomography in oesophageal squamous cell carcinoma

    International Nuclear Information System (INIS)

    Chen Tianwu; Yang Zhigang; Dong Zhihui; Li Yuan; Yao Jin; Wang Qiling; Qian Lingling

    2011-01-01

    Purpose: To propose a low-dose method at tube current-time product of 50 mAs for whole tumour first-pass perfusion of oesophageal squamous cell carcinoma using 64-section multidetector row computed tomography (MDCT), and to assess the original image quality and accuracy of perfusion parameters. Materials and methods: Fifty-nine consecutive patients with confirmed oesophageal squamous cell carcinomas were enrolled into our study, and underwent whole tumour first-pass perfusion scan with 64-section MDCT at 50 mAs. Image data were statistically reviewed focusing on original image quality demonstrated by image-quality scores and signal-to-noise (S/N) ratios; and perfusion parameters including perfusion (PF, in ml/min/ml), peak enhanced density (PED, in HU), time to peak (TTP, in seconds) and blood volume (BV, in ml/100 g) for the tumour. To test the interobserver agreement of perfusion measurements, perfusion analyses were repeatedly performed. Results: Original image-quality scores were 4.71 ± 0.49 whereas S/N ratios were 5.21 ± 2.05, and the scores were correlated with the S/N ratios (r = 0.465, p < 0.0001). Mean values for PF, PED, TTP and BV of the tumour were 33.27 ± 24.15 ml/min/ml, 24.06 ± 9.87 HU, 29.42 ± 8.61 s, and 12.45 ± 12.22 ml/100 g, respectively. Intraclass correlation coefficient between the replicated measurements of each perfusion parameter was greater than 0.99, and mean difference of the replicated measurements of each parameter was close to zero. Conclusion: Whole tumour first-pass perfusion with 64-section MDCT at low-dose radiation could be reproducible to assess microcirculation in oesophageal squamous cell carcinoma without compromising subjective original image quality of the tumour.

  11. Preoperative differentiation between T1a and ≥T1b gallbladder cancer: combined interpretation of high-resolution ultrasound and multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Joo, Ijin; Baek, Jee Hyun; Kim, Jung Hoon; Han, Joon Koo; Choi, Byung Ihn; Lee, Jae Young; Park, Hee Sun

    2014-01-01

    To determine the diagnostic value of combined interpretation of high-resolution ultrasound (HRUS) and multidetector-row computed tomography (MDCT) for preoperative differentiation between T1a and ≥T1b gallbladder (GB) cancer. Eighty-seven patients with pathologically confirmed GB cancers (T1a, n = 15; ≥T1b, n = 72), who preoperatively underwent both HRUS and MDCT, were included in this retrospective study. Two reviewers independently determined the T-stages of the GB cancers on HRUS and MDCT using a five-point confidence scale (5, definitely T1a; 1, definitely ≥T1b). For individual modality interpretation, the lesions with scores ≥4 were classified as T1a, and, for combined modality interpretation, the lesions with all scores ≥4 in both modalities were classified as T1a. The McNemar test was used to compare diagnostic performance. The diagnostic accuracy of differentiation between T1a and ≥T1b GB cancer was higher using combined interpretation (90.8 % and 88.5 % for reviewers 1 and 2, respectively) than individual interpretation of HRUS (82.8 % and 83.9 %) or MDCT (74.7 % and 82.8 %) (P < 0.05, reviewer 1). Combined interpretations demonstrated 100 % specificity for both reviewers, which was significantly higher than individual interpretations (P < 0.05, both reviewers). Combined HRUS and MDCT interpretation may improve the diagnostic accuracy and specificity for differentiating between T1a and ≥T1b GB cancers. circle Differentiating between T1a and ≥T1b gallbladder cancer can help surgical planning. (orig.)

  12. Threshold-dependent variability of coronary artery calcification measurements - implications for contrast-enhanced multi-detector row-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moselewski, Fabian [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Ferencik, Maros [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Achenbach, Stephan [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Department of Internal Medicine II (Cardiology), University of Erlangen (Germany); Abbara, Suhny [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Cury, Ricardo C. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Booth, Sarah L. [Jean Mayer USDA Human Nutrition Research Center on Aging, 711 Washington St., Boston, MA 02114 (United States); Jang, Ik-Kyung [Division of Cardiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Brady, Thomas J. [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Hoffmann, Udo [Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States)]. E-mail: uhoffman@partners.org

    2006-03-15

    Introduction: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT). Methods: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM] at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT. Results: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 {+-} 68.7 HU versus 295 {+-} 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. Discussion: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT.

  13. Dose-reduced 16-slice multidetector-row spiral computed tomography in children with bronchoscopically suspected vascular tracheal stenosis - initial results

    International Nuclear Information System (INIS)

    Honnef, D.; Wildberger, J.E.; Das, M.; Hohl, C.; Mahnken, A.; Guenther, R.W.; Staatz, G.; Schnoering, H.; Vazquez-Jimenez, J.

    2006-01-01

    Purpose: To evaluate the diagnostic accuracy of contrast-enhanced dose-reduced 16-slice multidetector-row CT (MDCT) in newborns and infants with fiberoptic bronchoscopically suspected vascular-induced tracheal stenosis. Materials and Methods: 12 children (4 days to 3 years, 1.2-13.5 kg body weight) were examined using i.v. contrast-enhanced 16-slice MDCT (SOMATOM Sensation 16, Forchheim, Germany) without breath-hold and under sedation (11/12). All MDCTs were performed with a dose reduction. The beam collimation was 16 x 0.75 mm, except in the case of one child. MPRs along the tracheal axis in the x-, y- and z-directions and volume-rendering-reconstructions (VRTs) were calculated based on a secondary raw data set in addition to conventional axial slices. 2 radiologists used a three-point grade scale to evaluate the image quality, motion, and contrast media artifacts as well as the usefulness of the 2D- and 3D-reconstructions for determining the diagnosis. Statistical analysis was performed on the basis of a Kappa test. Results: In all cases the cause of the fiberoptic bronchoscopically suspected tracheal stenosis was revealed: compression due to the brachiocephalic trunk (n=7), double aortic arch (n=2), lusorian artery (n=1), vascular compression of the left main bronchus (n=2). In 3 patients further thoracic anomalies, such as tracheobronchial (n=2), and vascular (n=2) and vertebral (n=1) anomalies were found. The attenuation in the anomalous vessels was 307±140 HU. The image noise was 9.8±1.9 HU. The mean dose reduction was 82.7±3.2% compared to a standard adult thoracic CT. All examinations were rated as diagnostically good (median 1, range 1, k=1). 3D images did not show any stair artifacts (median 2, range 1-2, k=1). The image noise was minor to moderate and hardly any motion artifacts were seen (median 1, range 1-2, k=0.8). Contrast media artifacts were rated zero to minor (median 1.5, range 1-2, k=0.676). MPRs (median 1, range 1, k=1) and VRTs (median 1

  14. Estimation of aortic time-enhancement curve in pharmacokinetic analysis. Dynamic study by multi-detector row computed tomography

    International Nuclear Information System (INIS)

    Yamaguchi, Isao; Kidoya, Eiji; Higashimura, Kyoji; Hayashi, Hiroyuki; Suzuki, Masayuki

    2007-01-01

    This paper presents an introduction to the development of software that provides a physiologic model of contrast medium enhancement by incorporating available physiologic data and contrast medium pharmacokinetics to predict an organ-specific aortic time-enhancement curve (TEC) in computed tomography (CT) with various contrast medium injection protocols in patients of various heights, weights, cardiac output levels, and so on. The physiologic model of contrast medium enhancement was composed of six compartments for early contrast enhancement pharmacokinetics. Contrast medium is injected via the antecubital vein and distributed to the right side of the heart, the pulmonary compartment, the left side of the heart, and the aorta. It then circulates back to the right side of the heart via the systemic circulation. A computer-based, compartmental model of the aortic system was generated using human physiologic parameters and six differential equations to describe the transport of contrast medium. Aortic TEC generated by the computer-based physiologic model of contrast medium enhancement showed validity and agreement with clinical data and findings published previously. A computer-based physiologic model that may help predict organ-specific CT contrast medium enhancement for different injection protocols was developed. Such a physiologic model may have multiple clinical applications. (author)

  15. Use of multidetector-row computed tomography scan to detect pannus formation in prosthetic mechanical aortic valves.

    Science.gov (United States)

    Aladmawi, Mohamed A; Pragliola, Claudio; Vriz, Olga; Galzerano, Domenico

    2017-04-01

    Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus.

  16. Four-channel multidetector-row computed tomography in the evaluation of facial fractures - optimized parameters for acquisition and multiplanar reformation

    International Nuclear Information System (INIS)

    Omid, P. M.

    2002-08-01

    The first part of this thesis is designed to give the reader a comprehensive survey on the complex basic principles of computed tomography (CT), from the early beginning to the recent development of multidetector-row CT (MD-CT). Attention is focused on imaging of trauma in general and on imaging of facial fractures in particular. The second part of this thesis describes a clinical study performed to optimize acquisition protocols and multiplanar reformation (MPR) algorithms for the evaluation of facial fractures using MD-CT, which has not been yet described in literature. For this study, a cadaver head with artificial blunt facial trauma was examined using a 4-channel MD-CT scanner. The influence of acquisition parameters (collimation: 2x0.5 mm/4x1 mm/4x2.5 mm; tube current: 120 mAs/90 mAs/60 mAs), image reconstruction algorithms (standard vs. ultra-high resolution (UHR) modes; reconstructed slice thicknesses: 0.5 mm/1 mm/3 mm; increment: 0.3 mm/0.6 mm/1.5 mm), and reformation algorithms (slice thicknesses: 0.5 mm/1 mm/3 mm; overlap: 0.5 mm/1 mm/3 mm) on detectability of facial fractures in MPRs with MD-CT was analyzed. Effects of algorithms and parameters on image noise, artifacts and delineation of soft tissues were evaluated. The results of this study reliably demonstrate that fracture detection was significantly higher with thin MPRs (0.5/0.5 mm, 1/0.5 mm, 1/1 mm) (p = 0 .014) acquired with 2x0.5 mm collimation (p = 0 .046), in UHR mode (p .0005) with 120 mAs (p = 0 .025). Inter-observer variability showed very good agreement (κ > = 0 .942). Non-UHR mode, lower mAs and thick MPRs (3/0.5 mm, 3/1 mm, 3/0.5 mm) showed significantly decreased detectability. (author)

  17. Phantom-Calibrated versus Automatic Coronary Artery Mass Quantification with Multidetector-Row Computed Tomography: In Vitro and In Vivo Study

    Energy Technology Data Exchange (ETDEWEB)

    Serafin, Z.; Lasek, W.; Laskowska, K. (Dept. of Radiology and Diagnostic Imaging, Nicolaus Copernicus Univ., Collegium Medicum, Bydgoszcz (Poland))

    2008-11-15

    Background: Coronary artery calcium scoring is used as a method for cardiovascular risk stratification and monitoring of coronary heart disease. Automatic software-based calcium mass calculation has been proposed to improve the performance of the procedure. Purpose: To compare two algorithms of calcium mass measurement, automatic and phantom calibrated, with respect to correlation, measurement error, and accuracy in vitro and in vivo. Material and Methods: A cardiac phantom with calcium cylinder inserts was scanned with sequential non-overlapping collimation 4x2.5 mm, at 120 kV and 165 mAs. Fifty adults (37 men; mean age 46.2 years) were examined with the same settings using prospective electrocardiographic triggering to detect and quantify coronary artery calcifications. Calculations were performed with two methods: software-based automatic calcium mass measurement (ACM) and phantom-calibrated calcium mass measurement (CCM). Results: The total phantom calcium masses measured with ACM and CCM were 175.0+-13.8 mg and 163.0+-4.4 mg, respectively (P<0.0001), and ACM produced a higher mean error (4.5 vs. 3.2; P<0.05). Results of ACM and CCM were strongly correlated to each other (R=0.73-0.96; P<0.0001). Mean image noise in the patient study was 8.72+-1.68 HU. Results of patient calcium scoring with ACM and CCM were significantly different (median 70.3 mg and 59.7 mg, respectively; P<0.0001), with a mean systematic error of 17.5% (limit of agreement between 14.6% and 20.4%). The use of ACM resulted in an altered quartile classification for 14% of patients, as compared to CCM; all of these patients were classified into a higher category. Conclusion: Our data indicate that multidetector-row computed tomography coronary calcium mass determination based on dedicated phantom calibration shows lower measurement error than an automatic software-based calculation method. The tested automatic software does not yet seem to be a reliable option for calcium mass measurement

  18. Phantom-Calibrated versus Automatic Coronary Artery Mass Quantification with Multidetector-Row Computed Tomography: In Vitro and In Vivo Study

    International Nuclear Information System (INIS)

    Serafin, Z.; Lasek, W.; Laskowska, K.

    2008-01-01

    Background: Coronary artery calcium scoring is used as a method for cardiovascular risk stratification and monitoring of coronary heart disease. Automatic software-based calcium mass calculation has been proposed to improve the performance of the procedure. Purpose: To compare two algorithms of calcium mass measurement, automatic and phantom calibrated, with respect to correlation, measurement error, and accuracy in vitro and in vivo. Material and Methods: A cardiac phantom with calcium cylinder inserts was scanned with sequential non-overlapping collimation 4x2.5 mm, at 120 kV and 165 mAs. Fifty adults (37 men; mean age 46.2 years) were examined with the same settings using prospective electrocardiographic triggering to detect and quantify coronary artery calcifications. Calculations were performed with two methods: software-based automatic calcium mass measurement (ACM) and phantom-calibrated calcium mass measurement (CCM). Results: The total phantom calcium masses measured with ACM and CCM were 175.0±13.8 mg and 163.0±4.4 mg, respectively (P<0.0001), and ACM produced a higher mean error (4.5 vs. 3.2; P<0.05). Results of ACM and CCM were strongly correlated to each other (R=0.73-0.96; P<0.0001). Mean image noise in the patient study was 8.72±1.68 HU. Results of patient calcium scoring with ACM and CCM were significantly different (median 70.3 mg and 59.7 mg, respectively; P<0.0001), with a mean systematic error of 17.5% (limit of agreement between 14.6% and 20.4%). The use of ACM resulted in an altered quartile classification for 14% of patients, as compared to CCM; all of these patients were classified into a higher category. Conclusion: Our data indicate that multidetector-row computed tomography coronary calcium mass determination based on dedicated phantom calibration shows lower measurement error than an automatic software-based calculation method. The tested automatic software does not yet seem to be a reliable option for calcium mass measurement

  19. Measurement of cardiac ventricular volumes using multidetector row computed tomography: comparison of two- and three-dimensional methods

    International Nuclear Information System (INIS)

    Montaudon, M.; Laffon, E.; Berger, P.; Corneloup, O.; Latrabe, V.; Laurent, F.

    2006-01-01

    This study compared a three-dimensional volumetric threshold-based method to a two-dimensional Simpson's rule based short-axis multiplanar method for measuring right (RV) and left ventricular (LV) volumes, stroke volumes, and ejection fraction using electrocardiography-gated multidetector computed tomography (MDCT) data sets. End-diastolic volume (EDV) and end-systolic volume (ESV) of RV and LV were measured independently and blindly by two observers from contrast-enhanced MDCT images using commercial software in 18 patients. For RV and LV the three-dimensionally calculated EDV and ESV values were smaller than those provided by two-dimensional short axis (10%, 5%, 15% and 26% differences respectively). Agreement between the two methods was found for LV (EDV/ESV: r=0.974/0.910, ICC=0.905/0.890) but not for RV (r=0.882/0.930, ICC=0.663/0.544). Measurement errors were significant only for EDV of LV using the two-dimensional method. Similar reproducibility was found for LV measurements, but the three-dimensional method provided greater reproducibility for RV measurements than the two-dimensional. The threshold value supported three-dimensional method provides reproducible cardiac ventricular volume measurements, comparable to those obtained using the short-axis Simpson based method. (orig.)

  20. Accuracy of multidetector row computed tomography for the detection of transplant vasculopathy: comparison with invasive coronary angiography and intravascular ultrasound

    International Nuclear Information System (INIS)

    Carrascosa, P.; Capunay, C.; Carrascosa, J.; Perrone, S.; Deviggiano, A.; Lopez, E.M.; Lev, G.; Garcia, M.J.

    2009-01-01

    Objective: To evaluate the diagnostic accuracy of multidetector computed tomography (MDCT) for detection of luminal stenosis and cardiac allograft vasculopathy in comparison with coronary angiography (CA) and intravascular ultrasound (IVUS) respectively. Material and methods: Nineteen cardiac transplant patients scheduled for follow-up CA were included. MDCT coronary angiography was performed using a 16-row CT scanner within 7-14 days after CA and IVUS. Studies were analyzed by independent readers; two observers evaluated the CT datasets for the presence of coronary artery stenosis > 50% and allograft vasculopathy. Results: The sensitivity for detecting > 50% luminal stenosis was 80-88% and specificity, 98-99% and for detection of cardiac allograft vasculopathy, the sensitivity was 91-96% and specificity, 88-91%. Conclusion: In this preliminary series, our results indicate that MDCT coronary angiography was capable of detecting both significant coronary stenosis as well as diffuse intimal proliferation. This non-invasive procedure could be an alternative to CA and IVUS in the surveillance of heart transplant patients. (authors) [es

  1. The detectability of the origin of the inferior phrenic artery by paging method on multidetector-row CT angiography

    International Nuclear Information System (INIS)

    Terayama, Koshi

    2005-01-01

    We evaluated the ability to detect the origin of the inferior phrenic artery (IPA) by paging method on multidetector-row computed tomography (CT) angiography. In 104 patients who underwent multidetector-row CT, detectability of the origin of the IPA was assessed. In addition, in 30 patients in whom arteriographic study was performed, the IPA findings on multidetector-row CT were compared with those on arteriography. In 100 patients (96%) the origin of the right IPA was demonstrated with multidetector-row CT and in 93 patients (89%) the origin of the left IPA was demonstrated. CT angiographic findings concurred with arteriographic findings in all 30 patients (100%) who underwent arteriographic study. In conclusion, paging method on multidetector-row CT angiography provides valuable anatomical information regarding IPA. (author)

  2. Current status of multi-detector row helical CT in imaging of adult ...

    African Journals Online (AJOL)

    Current status of multi-detector row helical CT in imaging of adult acquired pancreatic diseases and assessing surgical neoplastic resectability. ... The presence of inflammation, masses, and vascular invasion was evaluated and interpreted images were obtained during each phase. Results were compared with surgery, ...

  3. Role of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography in diagnosis and management of pancreatic cancer; comparison with multidetector row computed tomography, magnetic resonance imaging and endoscopic ultrasonography.

    Science.gov (United States)

    Ergul, N; Gundogan, C; Tozlu, M; Toprak, H; Kadıoglu, H; Aydin, M; Cermik, T F

    2014-01-01

    We aimed to analyze the contribution of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) imaging to the diagnosis and management of pancreatic cancer compared with multidetector row computed tomography (MDCT), magnetic resonance imaging (MRI) and endoscopic ultrasonography (EUS). We retrospectively scanned the data of 52 patients who were referred for FDG PET/CT imaging for evaluation of pancreatic lesions greater than 10mm. The diagnostic performances of 4 imaging methods and the impact of PET/CT on the management of pancreatic cancer were defined. Pancreatic adenocarcinoma was diagnosed in 33 of 52 patients (63%), 15 patients had benign diseases of pancreas (29%), and 4 patients were normal (8%). Sensitivity and NPV of EUS and PET/CT were equal (100%) and higher than MDCT and MRI. Specificity, PPV and NPV of PET/CT were significantly higher than MDCT. However, sensitivities of two imaging methods were not significantly different. There was no significant difference between PET/CT and MRI and EUS for these values. When the cut-off value of SUVmax was 3.2, the most effective sensitivity and specificity values were obtained. PET/CT contributed to the management of pancreatic cancer in 30% of patients. FDG PET/CT is a valuable imaging method for the diagnosis and management of pancreatic cancer, especially when applied along with EUS as first line diagnostic tools. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  4. Accurate estimation of global and regional cardiac function by retrospectively gated multidetector row computed tomography. Comparison with cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Belge, Benedicte; Pasquet, Agnes; Vanoverschelde, Jean-Louis J.; Coche, Emmanuel; Gerber, Bernhard L.

    2006-01-01

    Retrospective reconstruction of ECG-gated images at different parts of the cardiac cycle allows the assessment of cardiac function by multi-detector row CT (MDCT) at the time of non-invasive coronary imaging. We compared the accuracy of such measurements by MDCT to cine magnetic resonance (MR). Forty patients underwent the assessment of global and regional cardiac function by 16-slice MDCT and cine MR. Left ventricular (LV) end-diastolic and end-systolic volumes estimated by MDCT (134±51 and 67±56 ml) were similar to those by MR (137±57 and 70±60 ml, respectively; both P=NS) and strongly correlated (r=0.92 and r=0.95, respectively; both P<0.001). Consequently, LV ejection fractions by MDCT and MR were also similar (55±21 vs. 56±21%; P=NS) and highly correlated (r=0.95; P<0.001). Regional end-diastolic and end-systolic wall thicknesses by MDCT were highly correlated (r=0.84 and r=0.92, respectively; both P<0.001), but significantly lower than by MR (8.3±1.8 vs. 8.8±1.9 mm and 12.7±3.4 vs. 13.3±3.5 mm, respectively; both P<0.001). Values of regional wall thickening by MDCT and MR were similar (54±30 vs. 51±31%; P=NS) and also correlated well (r=0.91; P<0.001). Retrospectively gated MDCT can accurately estimate LV volumes, EF and regional LV wall thickening compared to cine MR. (orig.)

  5. Multidetector-row CT: economics and workflow

    International Nuclear Information System (INIS)

    Pottala, K.M.; Kalra, M.K.; Saini, S.; Ouellette, K.; Sahani, D.; Thrall, J.H.

    2005-01-01

    With rapid evolution of multidetector-row CT (MDCT) technology and applications, several factors such ad technology upgrade and turf battles for sharing cost and profitability affect MDCT workflow and economics. MDCT workflow optimization can enhance productivity and reduce unit costs as well as increase profitability, in spite of decrease in reimbursement rates. Strategies for workflow management include standardization, automation, and constant assessment of various steps involved in MDCT operations. In this review article, we describe issues related to MDCT economics and workflow. (orig.)

  6. Multidetector-row computed tomography in the preoperative diagnosis of intestinal complications caused by clinically unsuspected ingested dietary foreign bodies: a case series emphasizing the use of volume rendering techniques

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Augusto Cesar Vieira; Torres, Ulysses dos Santos; Oliveira, Eduardo Portela de; Gual, Fabiana; Bauab Junior, Tufik, E-mail: usantor@yahoo.com.br [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Serv. de Radiologia e Diagnostico por Imagem; Westin, Carlos Eduardo Garcia [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Cirurgia Geral; Cardoso, Luciana Vargas [Faculdade de Medicina de Sao Jose do Rio Preto (FAMERP), SP (Brazil). Hospital de Base. Setor de Tomografia Computadorizada

    2013-11-15

    Objective: the present study was aimed at describing a case series where a preoperative diagnosis of intestinal complications secondary to accidentally ingested dietary foreign bodies was made by multidetector-row computed tomography (MDCT), with emphasis on complementary findings yielded by volume rendering techniques (VRT) and curved multiplanar reconstructions (MPR). Materials and Methods: The authors retrospectively assessed five patients with surgically confirmed intestinal complications (perforation and/or obstruction) secondary to unsuspected ingested dietary foreign bodies, consecutively assisted in their institution between 2010 and 2012. Demographic, clinical, laboratory and radiological data were analyzed. VRT and curved MPR were subsequently performed. Results: preoperative diagnosis of intestinal complications was originally performed in all cases. In one case the presence of a foreign body was not initially identified as the causal factor, and the use of complementary techniques facilitated its retrospective identification. In all cases these tools allowed a better depiction of the entire foreign bodies on a single image section, contributing to the assessment of their morphology. Conclusion: although the use of complementary techniques has not had a direct impact on diagnostic performance in most cases of this series, they may provide a better depiction of foreign bodies' morphology on a single image section. (author)

  7. Multidetector row CT for imaging the paediatric tracheobronchial tree

    International Nuclear Information System (INIS)

    Papaioannou, Georgia; Young, Carolyn; Owens, Catherine M.

    2007-01-01

    The introduction of multidetector row computed tomography (MDCT) scanners has altered the approach to imaging the paediatric thorax. In an environment where the rapid acquisition of CT data allows general hospitals to image children instead of referring them to specialist paediatric centres, it is vital that general radiologists have access to protocols appropriate for paediatric applications. Thus a dramatic reduction in the delivered radiation dose is ensured with optimal contrast bolus delivery and timing, and inappropriate repetition of the scans is avoided. This article focuses on the main principles of volumetric CT imaging that apply generically to all MDCT scanners. We describe the reconstruction techniques for imaging the paediatric thorax and the low-dose protocols used in our institution on a 16-slice detector CT scanner. Examples of the commonest clinical applications are also given. (orig.)

  8. Gadolinium Ethoxybenzyl Diethylenetriamine Pentaacetic Acid (Gd-EOB-DTPA)-Enhanced Magnetic Resonance Imaging and Multidetector-Row Computed Tomography for the Diagnosis of Hepatocellular Carcinoma: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Ye, Feng; Liu, Jun; Ouyang, Han

    2015-08-01

    The purpose of this meta-analysis was to compare the diagnostic accuracy of gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) and multidetector-row computed tomography (MDCT) for hepatocellular carcinoma (HCC).Medline, Cochrane, EMBASE, and Google Scholar databases were searched until July 4, 2014, using combinations of the following terms: gadoxetic acid disodium, Gd-EOB-DTPA, multidetector CT, contrast-enhanced computed tomography, and magnetic resonance imaging. Inclusion criteria were as follows: confirmed diagnosis of primary HCC by histopathological examination of a biopsy specimen; comparative study of MRI using Gd-EOB-DTPA and MDCT for diagnosis of HCC; and studies that provided quantitative outcome data. The pooled sensitivity and specificity of the 2 methods were compared, and diagnostic accuracy was assessed with alternative-free response receiver-operating characteristic analysis.Nine studies were included in the meta-analysis, and a total of 1439 lesions were examined. The pooled sensitivity and specificity for 1.5T MRI were 0.95 and 0.96, respectively, for 3.0T MRI were 0.91 and 0.96, respectively, and for MDCT were 0.74 and 0.93, respectively. The pooled diagnostic odds ratio for 1.5T and 3.0T MRI was 242.96, respectively, and that of MDCT was 33.47. To summarize, Gd-EOB-DTPA-enhanced MRI (1.5T and 3.0T) has better diagnostic accuracy for HCC than MDCT.

  9. Multidetector-row CT finding of gastric cystic lymphangioma: A case report

    International Nuclear Information System (INIS)

    Kang, Tae Wook; Lee, Soon Jin; Song, Hye Jong

    2008-01-01

    Cystic lymphangioma is a rare benign submucosal tumor of the stomach thought to originate from sequestered lymphatic tissue that fails to communicate with the normal lymphatic system. The most commonly used method of evaluation for cystic lymphangioma of the stomach is an endoscopic ultrasonography. We report the multidetector-row computed tomography findings of a cystic lymphangioma of the stomach in a 46-year-old man along with a literature review

  10. Relationship between noise, dose, and pitch in cardiac multi-detector row CT.

    Science.gov (United States)

    Primak, Andrew N; McCollough, Cynthia H; Bruesewitz, Michael R; Zhang, Jie; Fletcher, Joel G

    2006-01-01

    In spiral computed tomography (CT), dose is always inversely proportional to pitch. However, the relationship between noise and pitch (and hence noise and dose) depends on the scanner type (single vs multi-detector row) and reconstruction mode (cardiac vs noncardiac). In single detector row spiral CT, noise is independent of pitch. Conversely, in noncardiac multi-detector row CT, noise depends on pitch because the spiral interpolation algorithm makes use of redundant data from different detector rows to decrease noise for pitch values less than 1 (and increase noise for pitch values > 1). However, in cardiac spiral CT, redundant data cannot be used because such data averaging would degrade the temporal resolution. Therefore, the behavior of noise versus pitch returns to the single detector row paradigm, with noise being independent of pitch. Consequently, since faster rotation times require lower pitch values in cardiac multi-detector row CT, dose is increased without a commensurate decrease in noise. Thus, the use of faster rotation times will improve temporal resolution, not alter noise, and increase dose. For a particular application, the higher dose resulting from faster rotation speeds should be justified by the clinical benefits of the improved temporal resolution. RSNA, 2006

  11. Myocardial enhancement pattern in patients with acute myocardial infarction on two-phase contrast-enhanced Ecg-gated multidetector-row computed tomography

    International Nuclear Information System (INIS)

    Ko, S.M.; Seo, J.B.; Hong, M.K.; Do, K.H.; Lee, S.H.; Lee, J.S.; Song, J.W.; Park, S.J.; Park, S.W.; Lim, T.H.

    2006-01-01

    Aim: To evaluate the myocardial enhancement pattern of the left ventricle on two-phase contrast-enhanced electrocardiogram (ECG)-gated multidetector computed tomography (MDCT) images in patients with acute myocardial infarction (AMI). METHODS: Two-phase contrast-enhanced ECG-gated MDCT examinations were performed in 16 patients with AMI. The presence, location and pattern of myocardial enhancement were evaluated. MDCT findings were compared with the catheter angiographic results. RESULTS: Subendocardial (n=9) or transmural (n=6) area of early perfusion defects of the myocardium was detected in 15 of 16 patients (94%) on early-phase CT images. Variable delayed myocardial enhancement patterns on late-phase CT images were observed in 12 patients (75%): (1) subendocardial residual perfusion defect and subepicardial late enhancement (n=6); (2) transmural late enhancement (n=1); (3) isolated subendocardial late enhancement (n=1); and (4) isolated subendocardial residual perfusion defect (n=2). On catheter angiography, 14 of 15 corresponding coronary arteries showed significant stenosis. CONCLUSION: Variable abnormal myocardial enhancement pattern was seen on two-phase, contrast-enhanced ECG-gated MDCT in patients with AMI. Assessment of myocardial attenuation on CT angiography gives additional information of the location and extent of infarction

  12. Multidetector-Row Computed Tomography in the Evaluation of Transjugular Intrahepatic Portosystemic Shunt Performed with Expanded-Polytetrafluoroethylene-Covered Stent-Graft

    International Nuclear Information System (INIS)

    Fanelli, Fabrizio; Bezzi, Mario; Bruni, Antonio; Corona, Mario; Boatta, Emanuele; Lucatelli, Pierleone; Passariello, Roberto

    2011-01-01

    We assessed, in a prospective study, the efficacy of multidetector spiral computed tomography (MDCT) in the evaluation of transjugular intrahepatic portosystemic shunt (TIPS) patency in patients treated with the Viatorr (Gore, Flagstaff, AZ) expanded-polytetrafluoroethylene (e-PTFE)-covered stent-graft. Eighty patients who underwent TIPS procedure using the Viatorr self-expanding e-PTFE stent-graft were evaluated at follow-up of 1, 3, 6, and 12 months with clinical and laboratory tests as well as ultrasound–color Doppler (USCD) imaging. In case of varices, upper gastrointestinal endoscopy was also performed. In addition, the shunt was evaluated using MDCT at 6 and 12 months. In all cases of abnormal findings and discrepancy between MDCT and USCD, invasive control venography was performed. MDCT images were acquired before and after injection of intravenous contrast media on the axial plane and after three-dimensional reconstruction using different algorithms. MDCT was successfully performed in all patients. No artefacts correlated to the Viatorr stent-graft were observed. A missing correlation between UCSD and MDCT was noticed in 20 of 80 (25%) patients. Invasive control venography confirmed shunt patency in 16 (80%) cases and shunt malfunction in 4 (20%) cases. According to these data, MDCT sensitivity was 95.2%; specificity was 96.6%; and positive (PPV) and negative predictive values (NPV) were 90.9 and 98.2%, respectively. USCD sensitivity was 90%; specificity was 75%; and PPV and NPV were 54.5 and 95.7%, respectively. A high correlation (K value = 0.85) between MDCT and invasive control venography was observed. On the basis of these results, MDCT shows superior sensitivity and specificity compared with USCD in those patients in whom TIPS was performed with the Viatorr stent-graft. MDCT can be considered a valid tool in the follow-up of these patients.

  13. Preoperative assessment of hilar cholangiocarcinoma using multidetector-row CT. Correlation with histopathological findings

    International Nuclear Information System (INIS)

    Watadani, Takeyuki; Akahane, Masaaki; Ohtomo, Kuni; Yoshikawa, Takeharu

    2008-01-01

    Our aim was to investigate the diagnostic reliability of multidetector-row computed tomography (MDCT) for preoperative assessment of local tumoral spread in hilar cholangiocarcinoma. Thirteen of 30 consecutive patients with hilar cholangiocarcinoma who underwent surgery, excluding 17 patients who underwent biliary drainage or preoperative portal embolization, were retrospectively evaluated. Using MDCT systems of 4 detector rows or 16 detector rows, plain and dynamic contrast-enhanced images of three phases were obtained. Extent of tumor spread and lymph node metastasis were assessed with MDCT and compared with histopathological findings. The Bismuth-Corlette classification of hilar cholangiocarcinoma with MDCT were type I, 1 patient; type IIIa, 3 patients; type IIIb, 4 patients; and type IV, 5 patients; those with histopathological findings were type I, 1 patient; type IIIa, 2 patients; type IIIb, 4 patients; and type IV, 6 patients. One patient diagnosed as type IIIa with MDCT was pathologically diagnosed as type IV. Accuracy of MDCT in tumoral spread was 92.3%, although that of lymph node metastasis was 54%. MDCT is likely to play an important role in evaluation of focal lesion spread especially in intrapancreatic tumor invasion, although a greater number of cohort cases are necessary to clearly define its role. (author)

  14. Sacroiliitis in Ankylosing Spondylitis: Comparison with Multidetector Row CT and Plain Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Ji Youn; Joo, Kyung Bin; Choi, Byeong Kyoo; Ryu, Jeong Ah; Kim, Tae Hwan; Choi, Woo Jung [Hanyang University Hospital, Seoul (Korea, Republic of)

    2009-03-15

    The objective of our study was to compare multidetector row CT and the plain radiographs for making the diagnosis and grading the sacroiliitis that accompanies ankylosing spondylitis. We wanted to determine the role of multidetector row CT for the evaluation of the sacroilitis in patients with ankylosing spondylitis. One hundred ninety two patients with clinically suspected ankylosing spondylitis were evaluated by conventional radiography and multidetector row CT. Two musculoskeletal radiologists retrospectively analyzed the images, and they graded the sacroiliitis using the modified New York Criteria. Multidetector row CT demonstrated a significantly higher sensitivity (74.5%, 83.3%) than did plain radiography (59.9%, 66.7%) for detecting early sacroiliitis (p<0.05). Multidetector row CT showed a higher grade of sacroiliitis in 114 and 127 of 384 sacroiliac joints. Performing multidetector row CT rather than plain radiography for making the diagnoses of accompanying ankylosing spondylitis allows an early start of treatment with a subsequently improved prognosis

  15. Multidetector-row CT duodenography in familial adenomatous polyposis: a pilot study

    International Nuclear Information System (INIS)

    Taylor, S.A.; Halligan, S.; Moore, L.; Saunders, B.P.; Gallagher, M.; Phillips, R.K.S.; Bartram, C.I.

    2004-01-01

    AIM: To investigate the feasibility of using multidetector-row computed tomography (CT) duodenography to stage duodenal polyposis in patients with familial adenomatous polyposis. MATERIALS AND METHODS: Six patients underwent multidetector-row CT duodenography before upper gastrointestinal endoscopy. A single-blinded radiologist used a surface shaded three-dimensional endoluminal fly though and two-dimensional axial and multiplanar reformats to assign a score for maximum polyp size and number based on the Spigelman classification. Comparison was made with the corresponding Spigelman scores obtained from subsequent endoscopy. RESULTS: CT duodenography was technically successful in five of six patients. The CT derived Spigelman score based on maximum polyp size was accurate in all five patients. The CT derived Spigelman score based on polyp number was accurate in only two cases: Polyp number was overestimated in one patient and underestimated in a further two. In retrospect, fine carpeting of tiny duodenal polyps was poorly visualized with CT. CONCLUSIONS: CT duodenography is technically feasible and accurately predicts maximum polyp size but CT estimates of polyp number are relatively inaccurate. CT duodenography potentially has a useful role for duodenal surveillance in those patients intolerant of conventional endoscopy

  16. Radiological emergency room management with emphasis on multidetector-row

    Energy Technology Data Exchange (ETDEWEB)

    Philipp, M.O.; Kubin, K.; Hoermann, M.; Metz, V.M. E-mail: viktor.metz@univie.ac.at

    2003-10-01

    Trauma is the fifth leading cause of death after disease of the cardiovascular system, malignomas and disease of the respiratory and digestive system. The management of severely injured patients, including radiological imaging, is a matter of ongoing development. In particular, as for the imaging modalities, multidetector-row CT represents a substantial refinement in the diagnostic work-up of multitrauma patients. Sufficient therapy within the first hour after trauma increases the patient's chances for survival significantly. Thus, therapeutic procedures and diagnostic evaluation have to be concomitant events, performed by a multidisciplinary team, namely trauma surgeon, anesthesiologist and, last but not least, radiologist. The increased performance of multidetector-row CT leads to increased spatial resolution, which is a prerequisite for sophisticated two- and three-dimensional postprocessing. The increased volume coverage speed allows for comprehensive whole-body CT at still high levels of spatial resolution, resulting in significant spare of time which influences patient's survival. Using this technique conventional imaging such as plane film or angiography may be omitted.

  17. Traumatic thoracic injury: the role of Multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Joo; Kang, Doo Kyung; Kim, Tae Hee [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2006-05-15

    The introduction of Multidetector-row CT (MDCT) has revolutionized the diagnostic strategy of multitrauma patients. The rapid acquisition of a large scanning volume with a thin slice collimation allows for motion-free images of high spatial resolution, and this enables the application of the multiplanar reformat (MPR) and 3D volume-rendering (VR) images. The MPR images more accurately demonstrate aortic rupture or dissection, diaphragmatic injuries and fracture of vertebrae, sternum and costal cartilages. Diagnosing vascular injuries can be aided by using the MIP images. Rib fracture, trachea and bronchial laceration are more easily detected by the 3D images, while airway and vascular injuries can be detected from performing virtual endoscopy. We introduce our current CT imaging protocol and we present our clinical experience with using MDCT in the assessment of patients with blunt thoracic trauma.

  18. Recent technologic advances in multi-detector row cardiac CT.

    Science.gov (United States)

    Halliburton, Sandra Simon

    2009-11-01

    Recent technical advances in multi-detector row CT have resulted in lower radiation dose, improved temporal and spatial resolution, decreased scan time, and improved tissue differentiation. Lower radiation doses have resulted from the use of pre-patient z collimators, the availability of thin-slice axial data acquisition, the increased efficiency of ECG-based tube current modulation, and the implementation of iterative reconstruction algorithms. Faster gantry rotation and the simultaneous use of two x-ray sources have led to improvements in temporal resolution, and gains in spatial resolution have been achieved through application of the flying x-ray focal-spot technique in the z-direction. Shorter scan times have resulted from the design of detector arrays with increasing numbers of detector rows and through the simultaneous use of two x-ray sources to allow higher helical pitch. Some improvement in tissue differentiation has been achieved with dual energy CT. This article discusses these recent technical advances in detail.

  19. Breast multidetector-row CT with histopathologic correlation

    International Nuclear Information System (INIS)

    Takeuchi, Makiko; Yamashita, Akiyoshi; Ohgi, Kazuyuki; Kobori, Kenichi; Furukawa, Takashi

    2004-01-01

    The purpose of this study was to evaluate the correlation between multidetector-row CT (MDCT) and histopathologic findings using the same MDCT image as the histopathologic cross-section. MDCT with contrast enhancement was performed in 10 patients with breast cancers (8 invasive ductal carcinomas, one invasive lobular carcinoma, and one non-invasive ductal carcinoma). We tried to reconstruct multiplanar reconstructions (MPR) in the same plane as the histopathologic cross-section, and we evaluated the histopathologic findings of the false-positive lesions. In all cases, we obtained the same MDCT image as the histopathologic cross-section. There were 10 main lesions and 18 other lesions. In the other lesions, we found no false-negative lesions and 11 false-positive lesions. False-positive lesions included periductal fibrosis, cystic change, duct papillomatosis, sclerosing adenosis, fibroadenoma, and others. Using MDCT of the breast, it is possible to obtain good correlation between CT images and histopathologic findings. MDCT is thought to be useful in the evaluation CT findings on the basis of histopathologic evidence. (author)

  20. Chronic intestinal pseudo-obstruction in adult patients: multidetector row helical CT features

    International Nuclear Information System (INIS)

    Merlin, Aurelie; Soyer, Philippe; Boudiaf, Mourad; Hamzi, Lounis; Rymer, Roland

    2008-01-01

    Chronic intestinal pseudo-obstruction (CIPO) is a rare condition due to severe gastrointestinal motility disorder. Adult patients with CIPO experience symptoms of mechanical obstruction, but reliable clinical signs that may help distinguish between actual mechanical obstruction and CIPO are lacking. Additionally, abdominal plain films that commonly show bowel dilatation with air-fluid levels do not reach acceptable degrees of specificity to exclude actual obstruction. Therefore, most adult patients with CIPO usually undergo multiple and often fruitless surgery, often leading to repeated bowel resections before diagnosis is made. In these patients who present with abdominal signs mimicking symptoms that would warrant surgical exploration, multidetector-row helical CT (MDCT) is helpful to resolve this diagnostic dilemma. MDCT shows a diffusely distended bowel and helps to rule out a mechanical cause of obstruction, thus suggesting CIPO and obviating the need for unnecessary laparotomy. In adult patients with CIPO, MDCT may show pneumatosis intestinalis, pneumoperitoneum or intussusception. However, these conditions generally do not require surgery in patients with CIPO. This pictorial essay presents the more and less common MDCT features of CIPO in adult patients, to make the reader more familiar with this disease. (orig.)

  1. T-staging of gastric cancer of air-filling multidetector-row CT: Comparison with hydro-multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Kumano, Seishi, E-mail: kumano@radiol.med.kindai.ac.jp [Department of Radiology, Kinki University School of Medicine, Osakasayama, Osaka 589-8511 (Japan); Okada, Masahiro; Shimono, Taro; Kuwabara, Masatomo; Yagyu, Yukinobu; Imaoka, Izumi; Ashikaga, Ryuichiro; Ishii, Kazunari; Murakami, Takamichi [Department of Radiology, Kinki University School of Medicine, Osakasayama, Osaka 589-8511 (Japan)

    2012-11-15

    Purpose: The purpose of this study was to evaluate the accuracy of T-staging of gastric cancer by air-filling multidetector-row CT (air-MDCT) compared with water-filling MDCT (hydro-MDCT). Materials and methods: One hundred fifteen patients with histologically diagnosed gastric cancer were included in this study. Fifty-eight patients underwent air-MDCT, and the remaining 57 had hydro-MDCT using a 64-channel scanner. Based on the volumetric data of contrast-enhanced MDCT obtained about 75 s after intravenously injecting 525 mg iodine per kilogram patients weight (525 mgI/kg) nonionic contrast material at the rate of 2 ml/s, oblique coronal and oblique sagittal multi-planar reformatted images perpendicular to the stomach wall, including the tumor, were reconstructed on a workstation. Mural invasion of gastric cancer into the gastric wall, as visualized by CT, was classified according to the TNM classification, and the results of T-staging by MDCT were compared with those by pathologic analysis after surgery. Results: Correct assessment of T-staging by air-CT was achieved in 48 of 58 patients (83%), and that by hydro-MDCT was 49 of 57 patients (86%). The sensitivity, specificity, and accuracy of the technique in determining the invasion of serosa were 88%, 93%, and 91% for air-CT and 83%, 95%, and 91% for hydro-CT. There were no significant differences between hydro-MDCT and air-MDCT in sensitivity (P = 0.73), specificity (P = 0.71) and accuracy (P = 0.98). Conclusion: Air-MDCT is a very valuable tool in T-staging of gastric cancer as well as hydro-MDCT.

  2. Use of multidetector row CT with volume renderings in right lobe living liver transplantation

    International Nuclear Information System (INIS)

    Ishifuro, Minoru; Akiyama, Yuji; Kushima, Toshio; Horiguchi, Jun; Nakashige, Aya; Tamura, Akihisa; Marukawa, Kazushi; Fukuda, Hiroshi; Ono, Chiaki; Ito, Katsuhide

    2002-01-01

    Multidetector row CT is a feasible diagnostic tool in pre- and postoperative liver partial transplantation. We can assess vascular anatomy and liver parenchyma as well as volumetry, which provide useful information for both donor selection and surgical planning. Disorders of the vascular and biliary systems are carefully observed in recipients. In addition, we evaluate liver regeneration of both the donor and the recipient by serial volumetry. We present how multidetector row CT with state-of-the-art three-dimensional volume renderings may be used in right lobe liver transplantation. (orig.)

  3. CT paging arteriography with a multidetector-row CT. Advantages in splanchnic arterial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Seiji [Keio Univ., Tokyo (Japan). School of Medicine

    1999-11-01

    The purpose of this study is to assess the utility of CT paging arteriography with a multidetector-row CT as a replacement for conventional angiography in the evaluation of splanchnic arterial anomalies. Sixty-three patients underwent CT paging arteriography with a multidetector-row CT. In the 56 patients with conventional angiographic correlation, there was only one minor disagreement with CT paging arteriography. In the 7 patients who underwent IVDSA (intra venous digital subtraction angiography), CT paging arteriography defined four hepatic arterial anomalies which could not be depicted by IVDSA. In conclusion, CT paging arteriography provides noninvasive means to identify splanchnic arterial anomalies. (author)

  4. Accuracy of multidetector-row CT in diagnosing lymph node metastasis in patients with gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Takuro; Kurokawa, Yukinori; Takiguchi, Shuji; Miyazaki, Yasuhiro; Takahashi, Tsuyoshi; Yamasaki, Makoto; Miyata, Hiroshi; Nakajima, Kiyokazu; Mori, Masaki; Doki, Yuichiro [Osaka University, Graduate School of Medicine, Department of Gastroenterological Surgery, Suita, Osaka (Japan)

    2014-08-06

    The purpose of this study was to determine the optimal cut-off value of lymph node size for diagnosing metastasis in gastric cancer with multidetector-row computed tomography (MDCT) after categorizing perigastric lymph nodes into three regions. The study included 90 gastric cancer patients who underwent gastrectomy. The long-axis diameter (LAD) and short-axis diameter (SAD) of all visualized lymph nodes were measured with transverse MDCT images. The locations of lymph nodes were categorized into three regions: lesser curvature, greater curvature, and suprapancreatic. The diagnostic value of lymph node metastasis was assessed with receiver operating characteristic (ROC) analysis. The area under the curve was larger for SAD than LAD in all groups. The optimal cut-off values of SAD were determined as follows: overall, 9 mm; differentiated type, 9 mm; undifferentiated type, 8 mm; lesser curvature region, 7 mm; greater curvature region, 6 mm; and suprapancreatic region, 9 mm. The diagnostic accuracies for lymph node metastasis using individual cut-off values were 71.1 % based on histological type and 76.6 % based on region of lymph node location. The diagnostic accuracy of lymph node metastasis in gastric cancer was improved by using individual cut-off values for each lymph node region. (orig.)

  5. Detection, visualization and evaluation of anomalous coronary anatomy on 16-slice multidetector-row CT

    International Nuclear Information System (INIS)

    Ooijen, Peter M.A. van; Dorgelo, Joost; Oudkerk, Matthijs; Zijlstra, Felix

    2004-01-01

    Early identification and evaluation of relatively frequent anomalous coronary anatomy is quite relevant because of the occurrence of sudden cardiac death or related symptoms of myocardial ischemia. Selective coronary angiography (CAG) is invasive, expensive and cannot always provide the required information adequately. Recently, non-invasive imaging techniques such as magnetic resonance imaging and multidetector-row computed tomography (MDCT) have been shown to provide a good anatomical view of the coronary artery tree. This study aims to demonstrate the value of 16-MDCT for evaluation of anomalous coronary anatomy. In 13 patients scanned using 16-MDCT, six different coronary anomalies were diagnosed [two absent left main, one single vessel left coronary artery (LCA), three LCA originating from the right (two with interarterial course), six right coronary artery originating from the left, one double left anterior descending (LAD)]. Mean diagnostic quality, recorded by two observers using a 5-point scale (1= non-diagnostic to 5= excellent diagnostic quality), resulted in a mean score of 3.73 (SD 1.19) without any non-diagnostic result. MDCT offers an accurate diagnostic modality to visualize the origin and course of anomalous coronary arteries by a three-dimensional display of anatomy. Shortcomings in CAG can be overcome by the use of contrast-enhanced MDCT. (orig.)

  6. Detection of intracranial aneurysms using multi-detector row CT 3D-angiography: comparison with operative findings

    Energy Technology Data Exchange (ETDEWEB)

    Han, You Mie; Lim, Soo Mee; Seo, Eui Kyo; Kim, Yoo Kyung [Mokdong Hospital, Ewha Womans University, Seoul (Korea, Republic of)

    2006-04-15

    To assess the efficacy of three-dimensional CT angiography (3D-CTA) using multi-detector row computed tomography (MDCT) in the evaluation of intracranial aneurysms in patients with non-traumatic acute subarachnoid hemorrhage and to describe those aneurysms which were not found 3D-CTA. 3D-CTA was done in 40 patients with non-traumatic subarachnoid hemorrhage by using a 16-slice MDCT; conventional digital subtraction angiography (DSA) was done in 36 of those patients within 12 hours. The CT and DSA images were reviewed by two radiologists and the site, size and neck of the aneurysms were evaluated. The results from these two modalities were then compared with the operative findings. We calculated the detection rates by 3D-CTA and DSA and evaluated the size differences of aneurysms diagnosed with 3D-DTA and those found at surgery. We also analyzed the locations and sizes of aneurysms missed by 3D-CTA and attempted to explain these false negatives. A total of 55 aneurysms were surgically confirmed in 40 patients. 48 of these were detected pre-operatively by 3D-CTA. Thus, the detection rate by 3D-CTA was 87%. The size difference of aneurysms as calculated by 3-D CTA and found operatively was as follows: less than 1 mm in 17 cases, within 1-2 mm in 15 cases, and more than 2 mm in 16 cases. Seven aneurysms were not detected by 3D-CTA. The major cause of these missed aneurysms was their small size. The undetected aneurysms were less than 2 mm in size, except for 2 instances of PCoA aneurysms. One case was not detected due to difficult image evaluation. A possible explanation of the one remaining missed aneurysms was the filling of the aneurismal sac by thrombosis. Though there were some limitations in the detection of aneurysms, 3D-CTA using 16-channel MDCT may provide sufficient pre-operative information for the management of patients with intracranial aneurysms in cases of emergency operations or DSA-failure.

  7. Detection of intracranial aneurysms using multi-detector row CT 3D-angiography: comparison with operative findings

    International Nuclear Information System (INIS)

    Han, You Mie; Lim, Soo Mee; Seo, Eui Kyo; Kim, Yoo Kyung

    2006-01-01

    To assess the efficacy of three-dimensional CT angiography (3D-CTA) using multi-detector row computed tomography (MDCT) in the evaluation of intracranial aneurysms in patients with non-traumatic acute subarachnoid hemorrhage and to describe those aneurysms which were not found 3D-CTA. 3D-CTA was done in 40 patients with non-traumatic subarachnoid hemorrhage by using a 16-slice MDCT; conventional digital subtraction angiography (DSA) was done in 36 of those patients within 12 hours. The CT and DSA images were reviewed by two radiologists and the site, size and neck of the aneurysms were evaluated. The results from these two modalities were then compared with the operative findings. We calculated the detection rates by 3D-CTA and DSA and evaluated the size differences of aneurysms diagnosed with 3D-DTA and those found at surgery. We also analyzed the locations and sizes of aneurysms missed by 3D-CTA and attempted to explain these false negatives. A total of 55 aneurysms were surgically confirmed in 40 patients. 48 of these were detected pre-operatively by 3D-CTA. Thus, the detection rate by 3D-CTA was 87%. The size difference of aneurysms as calculated by 3-D CTA and found operatively was as follows: less than 1 mm in 17 cases, within 1-2 mm in 15 cases, and more than 2 mm in 16 cases. Seven aneurysms were not detected by 3D-CTA. The major cause of these missed aneurysms was their small size. The undetected aneurysms were less than 2 mm in size, except for 2 instances of PCoA aneurysms. One case was not detected due to difficult image evaluation. A possible explanation of the one remaining missed aneurysms was the filling of the aneurismal sac by thrombosis. Though there were some limitations in the detection of aneurysms, 3D-CTA using 16-channel MDCT may provide sufficient pre-operative information for the management of patients with intracranial aneurysms in cases of emergency operations or DSA-failure

  8. Multidetector row CT of the brain and carotid artery: a correlative analysis

    International Nuclear Information System (INIS)

    Saba, L.; Montisci, R.; Sanfilippo, R.; Mallarini, G.

    2009-01-01

    Aim: To evaluate the association between types of carotid plaque, the presence of prior ischaemic events detectable with CT, and patient's symptoms. Materials and methods: Between January 2004 and May 2006, 112 patients were evaluated using multidetector row computed tomography angiography (MDCTA) of the carotid arteries and computed tomography (CT) of the brain. Carotid arteries were categorized by evaluating the degree of stenosis according to North American Symptomatic Carotid Endarterectomy Trial (NASCET) criteria, the type of plaque, and the presence of plaque ulceration. The brain was assessed via CT for the presence, type, and position of lesions. Chi-square tests, Student's t test, and simple logistic regression analysis were performed and the Cohen kappa test was applied for interobserver variability measurement. Results: The Chi-square test indicated a statistically significant association between the presence of fatty plaques (p = 0.005) and CT-detectable lesions in the brain (p = 0.004). Moreover, the number of patients with CT-detectable brain lesions was greater in patients with >70% stenosis than in those with 70% stenosis and symptoms (p = 0.041), and an inverse association between calcified plaque and symptoms (p = 0.009). Conclusion: MDCTA allows adequate evaluation of the type of plaque. The results of the present study indicate that there is an association between cerebral lesions, symptoms, and fatty plaque in the carotid artery. The degree of stenosis also correlated with cerebral lesions and symptoms. According to the obtained data, the type of carotid plaque should be included among primary parameters in the classification of patients' risk class.

  9. Diagnostic value of multidetector row CT in rectal cancer staging: comparison of multiplanar and axial images with histopathology

    International Nuclear Information System (INIS)

    Sinha, R.; Verma, R.; Rajesh, A.; Richards, C.J.

    2006-01-01

    Aim: Although magnetic resonance (MR) imaging is widely used for rectal cancer staging, many centres in the UK perform computed tomography (CT) for staging rectal cancer at present. Furthermore in a small proportion of cases contraindications to MR imaging may lead to staging using CT. The purpose of this study was to evaluate the accuracy of current generation multidetector row CT (MDCT) in local staging of rectal cancer. In particular the accuracy of multiplanar (MPR) versus axial images in the staging of rectal cancer was assessed. Material and methods: Sixty-nine consecutive patients were identified who had undergone staging of rectal cancer on CT. The imaging data were reviewed as axial images and then as MPR images (coronal and sagittal) perpendicular and parallel to the tumour axis. CT staging on axial and MPR images was then compared to histopathological staging. Results: MPR images detected more T4 and T3 stage tumours than axial images alone. The overall accuracy of T-staging on MPR images was 87.1% versus 73.0% for axial images alone. The overall accuracy of N staging on MPR versus axial images was 84.8% versus 70.7%. There was a statistically significant difference in the staging of T3 tumours between MPR and axial images (p < 0.001). Conclusion: Multidetector row CT has high accuracy for local staging of rectal cancer. Addition of MPR images to standard axial images provides higher accuracy rates for T and N staging of rectal cancer than axial images alone

  10. Venous variants and anomalies on routine abdominal multi-detector row CT

    International Nuclear Information System (INIS)

    Koc, Zafer; Ulusan, Serife; Oguzkurt, Levent; Tokmak, Naime

    2007-01-01

    Objective: This study aims to determine the types and prevalence rates of anatomic variations of the hepatic veins, portal vein, inferior vena cava and renal veins, and to establish statistical correlations between various anomalies and frequency differences between male and female using multi-detector row computed tomography (CT). Materials and methods: One thousand one hundred and twenty patients (588 men, 532 women) were evaluated with routine abdominal CT. Frequencies of different variants were noted and compared, and correlations between three categories of variation were tested. Results: In total, 1261 abdominal vein variants and anomalies were identified in 756 (67.5%) of 1120 patients. Six hundred and forty-two hepatic vein variants were detected in 468 (41.8%) patients. One or more inferior right hepatic veins were identified in 356 (31.8%) individuals, and tributary hepatic veins were detected in 147 (13.1%) patients. Portal vein variations and anomalies were observed in 307 (27.4%) cases. The most frequent of these was trifurcation (139 patients, 12.4%). A total of 311 inferior vena cava and renal vein variants were identified in 258 (23%) cases. Six patients (0.5%) exhibited inferior vena cava anomalies, 62 (5.5%) had circumaortic renal veins, 53 (4.7%) had retroaortic renal veins, and 210 (18.8%) had multiple renal veins. Conclusion: The prevalence of abdominal vein variations is high, and routine abdominal CT demonstrates these abnormalities very well. The data suggest that hepatic vein variants and multiple right renal veins are more frequent in women than in men, and that hepatic vein variation is correlated with portal vein variation

  11. Venous variants and anomalies on routine abdominal multi-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Koc, Zafer [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey)]. E-mail: koczafer@gmail.com; Ulusan, Serife [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey); Oguzkurt, Levent [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey); Tokmak, Naime [Baskent University, School of Medicine, Department of Radiology, Adana (Turkey)

    2007-02-15

    Objective: This study aims to determine the types and prevalence rates of anatomic variations of the hepatic veins, portal vein, inferior vena cava and renal veins, and to establish statistical correlations between various anomalies and frequency differences between male and female using multi-detector row computed tomography (CT). Materials and methods: One thousand one hundred and twenty patients (588 men, 532 women) were evaluated with routine abdominal CT. Frequencies of different variants were noted and compared, and correlations between three categories of variation were tested. Results: In total, 1261 abdominal vein variants and anomalies were identified in 756 (67.5%) of 1120 patients. Six hundred and forty-two hepatic vein variants were detected in 468 (41.8%) patients. One or more inferior right hepatic veins were identified in 356 (31.8%) individuals, and tributary hepatic veins were detected in 147 (13.1%) patients. Portal vein variations and anomalies were observed in 307 (27.4%) cases. The most frequent of these was trifurcation (139 patients, 12.4%). A total of 311 inferior vena cava and renal vein variants were identified in 258 (23%) cases. Six patients (0.5%) exhibited inferior vena cava anomalies, 62 (5.5%) had circumaortic renal veins, 53 (4.7%) had retroaortic renal veins, and 210 (18.8%) had multiple renal veins. Conclusion: The prevalence of abdominal vein variations is high, and routine abdominal CT demonstrates these abnormalities very well. The data suggest that hepatic vein variants and multiple right renal veins are more frequent in women than in men, and that hepatic vein variation is correlated with portal vein variation.

  12. Tuberculous Addison's disease: Morphological and quantitative evaluation with multidetector-row CT

    International Nuclear Information System (INIS)

    Ma Ensen; Yang Zhigang; Li Yuan; Guo Yingkun; Deng Yuping; Zhang Xiaochun

    2007-01-01

    Objective: To determine the characteristics of tuberculous Addison's disease on the axial and multiplanar reformatted (MPR) images of the multidetector-row computed tomography (MDCT). Materials and methods: The unenhanced and contrast-enhanced MDCT features in 19 patients with tuberculous Addison's disease were retrospectively assessed for the location, contour, size, calcification, attenuation, and enhancement patterns. The correlation between the duration of Addison's disease and the percentage of calcification presence was evaluated. Results: The adrenal glands were infected bilaterally in all of the 19 cases (100%, 38 glands). Enlargement of the glands appeared in 18 cases (94.7%, 36 glands) and the remaining one case (5.3%, two glands) showed atrophy bilaterally. Of the 36 enlarged adrenals, 13 (36.1%) had preserved contours, and the other 23 (63.9%) were mass-like. The size of the adrenals ranged from 0.6 to 4.8cm (mean 1.92+/-0.96cm). Calcification was revealed in 16 adrenals (16/38, 42.1%), increasing in incidence with disease progression. Fourteen of the 36 (38.9%) enlarged adrenals showed peripheral enhancement while the remaining 22 (61.1%) demonstrated heterogeneous enhancement. The ΔCT value, the attenuation measurement of mass-like lesions, was less in the central area (7+/-4HU) than that in the peripheral area (32+/-14HU) (P<0.01) between the unenhanced and contrast-enhanced scan. Conclusion: MDCT can reveal the characteristic morphology and CT attenuation in the tuberculous Addison's disease. Combined with its clinical presentations and biochemical findings, we can diagnose and stage adrenal tuberculosis with high specificity and accuracy on MDCT

  13. Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT

    International Nuclear Information System (INIS)

    Flohr, T. G.; Stierstorfer, K.; Suess, C.; Schmidt, B.; Primak, A. N.; McCollough, C. H.

    2007-01-01

    We present and evaluate a special ultrahigh resolution mode providing considerably enhanced spatial resolution both in the scan plane and in the z-axis direction for a routine medical multi-detector row computed tomography (CT) system. Data acquisition is performed by using a flying focal spot both in the scan plane and in the z-axis direction in combination with tantalum grids that are inserted in front of the multi-row detector to reduce the aperture of the detector elements both in-plane and in the z-axis direction. The dose utilization of the system for standard applications is not affected, since the grids are moved into place only when needed and are removed for standard scanning. By means of this technique, image slices with a nominal section width of 0.4 mm (measured full width at half maximum=0.45 mm) can be reconstructed in spiral mode on a CT system with a detector configuration of 32x0.6 mm. The measured 2% value of the in-plane modulation transfer function (MTF) is 20.4 lp/cm, the measured 2% value of the longitudinal (z axis) MTF is 21.5 lp/cm. In a resolution phantom with metal line pair test patterns, spatial resolution of 20 lp/cm can be demonstrated both in the scan plane and along the z axis. This corresponds to an object size of 0.25 mm that can be resolved. The new mode is intended for ultrahigh resolution bone imaging, in particular for wrists, joints, and inner ear studies, where a higher level of image noise due to the reduced aperture is an acceptable trade-off for the clinical benefit brought about by the improved spatial resolution

  14. Multi-detector row CT colonography: effect of collimation, pitch, and orientation on polyp detection in a human colectomy specimen.

    Science.gov (United States)

    Taylor, Stuart A; Halligan, Steve; Bartram, Clive I; Morgan, Paul R; Talbot, Ian C; Fry, Nicola; Saunders, Brian P; Khosraviani, Kirosh; Atkin, Wendy

    2003-10-01

    To investigate the effects of orientation, collimation, pitch, and tube current setting on polyp detection at multi-detector row computed tomographic (CT) colonography and to determine the optimal combination of scanning parameters for screening. A colectomy specimen containing 117 polyps of different sizes was insufflated and imaged with a multi-detector row CT scanner at various collimation (1.25 and 2.5 mm), pitch (3 and 6), and tube current (50, 100, and 150 mA) settings. Two-dimensional multiplanar reformatted images and three-dimensional endoluminal surface renderings from the 12 resultant data sets were examined by one observer for the presence and conspicuity of polyps. The results were analyzed with Poisson regression and logistic regression to determine the effects of scanning parameters and of specimen orientation on polyp detection. The percentage of polyps that were detected significantly increased when collimation (P =.008) and table feed (P =.03) were decreased. Increased tube current resulted in improved detection only of polyps with a diameter of less than 5 mm. Polyps of less than 5 mm were optimally depicted with a collimation of 1.25 mm, a pitch of 3, and a tube current setting of 150 mA; polyps with a diameter greater than 5 mm were adequately depicted with 1.25-mm collimation and with either pitch setting and any of the three tube current settings. Small polyps in the transverse segment (positioned at a 90 degrees angle to the z axis of scanning) were significantly less visible than those in parallel or oblique orientations (P detector row CT is highly dependent on collimation, pitch, and, to a lesser extent, tube current. Collimation of 1.25 mm, combined with pitch of 6 and tube current of 50 mA, provides for reliable detection of polyps 5 mm or larger while limiting the effective radiation dose. Polyps smaller than 5 mm, however, may be poorly depicted with use of these settings in the transverse colon. Copyright RSNA, 2003

  15. Detection and localization of acute upper and lower gastrointestinal (GI) bleeding with arterial phase multi-detector row helical CT

    Energy Technology Data Exchange (ETDEWEB)

    Jaeckle, T.; Stuber, G.; Hoffmann, M.H.K.; Jeltsch, M.; Schmitz, B.L.; Aschoff, A.J. [University Hospital of Ulm, Diagnostic and Interventional Radiology, Ulm (Germany)

    2008-07-15

    The purpose of this study was to evaluate the accuracy of multi-detector row helical CT (MDCT) for detection and localization of acute upper and lower gastrointestinal (GI) hemorrhage or intraperitoneal bleeding. Thirty-six consecutive patients with clinical signs of acute bleeding underwent biphasic (16- or 40-channel) MDCT. MDCT findings were correlated with endoscopy, angiography or surgery. Among the 36 patients evaluated, 26 were examined for GI bleeding and 10 for intraperitoneal hemorrhage. Confirmed sites of GI bleeding were the stomach (n = 5), duodenum (n = 5), small bowel (n = 6), large bowel (n = 8) and rectum (n = 2). The correct site of bleeding was identifiable on MDCT in 24/26 patients with GI bleeding. In 20 of these 24 patients, active CM extravasation was apparent during the exam. Among the ten patients with intraperitoneal hemorrhage, MDCT correctly identified the bleeding source in nine patients. Our findings suggest that fast and accurate localization of acute gastrointestinal and intraperitoneal bleeding is achievable on MDCT. (orig.)

  16. Detection and localization of acute upper and lower gastrointestinal (GI) bleeding with arterial phase multi-detector row helical CT

    International Nuclear Information System (INIS)

    Jaeckle, T.; Stuber, G.; Hoffmann, M.H.K.; Jeltsch, M.; Schmitz, B.L.; Aschoff, A.J.

    2008-01-01

    The purpose of this study was to evaluate the accuracy of multi-detector row helical CT (MDCT) for detection and localization of acute upper and lower gastrointestinal (GI) hemorrhage or intraperitoneal bleeding. Thirty-six consecutive patients with clinical signs of acute bleeding underwent biphasic (16- or 40-channel) MDCT. MDCT findings were correlated with endoscopy, angiography or surgery. Among the 36 patients evaluated, 26 were examined for GI bleeding and 10 for intraperitoneal hemorrhage. Confirmed sites of GI bleeding were the stomach (n = 5), duodenum (n = 5), small bowel (n = 6), large bowel (n = 8) and rectum (n = 2). The correct site of bleeding was identifiable on MDCT in 24/26 patients with GI bleeding. In 20 of these 24 patients, active CM extravasation was apparent during the exam. Among the ten patients with intraperitoneal hemorrhage, MDCT correctly identified the bleeding source in nine patients. Our findings suggest that fast and accurate localization of acute gastrointestinal and intraperitoneal bleeding is achievable on MDCT. (orig.)

  17. Multidetector-Row CT Findings of an Internal Supravesical Hernia: A Case Report

    International Nuclear Information System (INIS)

    Kim, Sang Won; Shin, Hyeong Cheol; Kim, Hyung Hwan; Kim, Young Tong; Kim, Il Young; Kang, Kil Ho

    2010-01-01

    A supravesical hernia occurs in the supravesical fossa and is either classified as an external or internal supravesical hernia. Most patients with internal supravesical hernias present with small bowel obstruction. Internal supravesical hernias are less common than external supravesical hernia. To date, there are few reports describing the radiological findings of supravesical hernias. To our knowledge, this is the first reported multidetector row CT (MDCT) depiction of this type of hernia. We report here on the MDCT findings of a patient with an internal supravesical hernia presenting with small bowel obstruction

  18. Evaluation of aortogenic embolic stroke using multi-detector row CT (MDCT)

    International Nuclear Information System (INIS)

    Mizuno, Masanori; Ooura, Kazumasa; Yamaguchi, Mao; Katsura, Noriyuki; Terayama, Yasuo

    2010-01-01

    Transesophageal cardioechography is one of the useful tools for detecting aortic arteriosclerosis causing aortogenic cerebral embolism. However, it is difficult to perform this method to all of the patients because of the technical difficulties due to patient's condition, especially the severity of atherosclerosis. To avoid the unexpected and adverse events, we are routinely applying multi-detector row CT (MDCT) to those patients. Among 10 cerebral embolic patients with unidentified embolic origin, MDCT revealed arteriosclerotic changes in aorta inducing mobile thrombus in 3 cases. The above data indicates that MDCT is safe and useful tool for diagnosis of aortogenic embolic stroke. (author)

  19. Evaluation of various image reconstruction parameters in lower extremity stents using multidetector-row CT angiography: initial findings

    International Nuclear Information System (INIS)

    Heuschmid, Martin; Wiesinger, Benjamin; Tepe, Gunnar; Luz, Oliver; Kopp, Andreas F.; Claussen, Claus D.; Duda, Stephan H.

    2007-01-01

    Image quality, visible lumen and patency of lower limb stents was assessed by multidetector-row computed tomography (MDCT) angiography using various reconstruction parameters and the results compared with conventional angiography. Fourteen patients (25 stents) were evaluated. From MDCT datasets, axial and coronal oblique reformations were reconstructed using differing reconstruction parameters (slice thickness, kernel, views). Artifacts and image quality were assessed using a five-degree scale (1=excellent, 5=poor). Visible stent diameter was measured. Stenosis severity was compared with calibrated catheter angiography. The image quality of medium and sharp image kernels were good/fair (1.9-2.4), while smooth kernel provided only acceptable/poor image quality (3.9-4.4). Coronal oblique images were rated superior to assess in-stent lumen rather than axial. Using medium and sharp kernels, the visible stent lumen was significantly greater than using smooth kernel (P<0.001). thirteen out of fourteen patients (24/25 stents) were correctly classified as patent. In one patient, in-stent stenosis (≥50%) was falsely diagnosed using CT angiography (CTA) with smooth kernel and was, therefore, rated as false positive. Coronal oblique views, as well as medium and sharp kernels, have shown the best results regarding image quality to assess stent patency in the lower limb. Therefore, MDCT could be a valuable non-invasive modality for stent imaging in the peripheral vasculature. (orig.)

  20. Fusion of the midplane with the left intersectional plane: a liver anatomical variation revisited with multidetector-row CT

    International Nuclear Information System (INIS)

    Lucidarme, Olivier; Taboury, Jacques; Savier, Eric; Hannoun, Laurent; Cadi, Mehdi; Grenier, Philippe A.

    2006-01-01

    This article updates the description of an anatomical variation of the liver, in which the gallbladder is adjacent to the ligamentum teres, that was described until now as ''right-sided ligamentum teres and right umbilical portion of the portal vein''. A study of eight patients showing this anatomical variation has led to a new archetypal anatomical description of the hepatic and portal veins, using multidetector-row computed tomography (MDCT) with three-dimensional (3D) volume-rendering (VR) reconstructions. While 2D axial imaging gave the same information, MDCT imaging with VR reconstructions provided a clear 3D visualization of this anatomical variation. Typical features can be described as follows: (1) juxtaposition of the ligamentum teres and the gallbladder; (2) typical portal vein branching with a right posterior branch, a left posterior branch and a main medial branch that terminates in the ligamentum teres; (3) two main hepatic veins and a hypotrophied medial hepatic vein. We think, based on the direct comparison of anatomical findings and knowledge of chronological embryological development, that this abnormality results from the defective development of the central part of the liver and not from the persistence of the right rather than the left umbilical vein. Because of the presence of only one medial plane, containing both the gallbladder and the ligamentum teres, we propose renaming it ''fusion of hepatic planes''. (orig.)

  1. Contribution of multi-detector row CT (MDCT) to decision making in the management of patients with small bowel obstruction or ileus

    International Nuclear Information System (INIS)

    Osada, Hisato; Watanabe, Wataru; Okada, Taketomo

    2007-01-01

    We retrospectively evaluated the contribution of multi-detector row CT (MDCT) to patient management decisions in 62 patients with small bowel obstruction or ileus. The sensitivity and specificity of MDCT diagnosis of small bowel obstruction with strangulation or closed loop were 78.9% (15/19) and 93.0% (40/43), respectively. In 19 patients with small bowel obstruction with strangulation or closed loop, the median interval between CT examination and the commencement of surgery was significantly longer in misdiagnosed patients than in those correctly diagnosed (43.3 vs. 4.5 hours, p<0.05). Only two patients displayed severe physical signs that required urgent surgical treatment. Our results suggest that MDCT plays a key role in the management of patients with small bowel obstruction. (author)

  2. Multidetector Row CT Detection of a Patent Foramen Ovale Causing Neurologic Deficits in an Adolescent: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Bin [Dept. of Radiology, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of); Kim, Dong Hun; Oh, Jae Hee [Dept. of Radiology, Chosun University College of Medicine, Gwangju (Korea, Republic of); Seo, Hye Sun [Dept. of Internal Medicine, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of); Suk, Eun Ha [Dept. of Anesthesiology and Pain Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2012-02-15

    A patent foramen ovale (PFO) is a persisting fetal circulation structural abnormality that can cause neurologic deficits such as migraine and cryptogenic stroke. Here we report a case of PFO diagnosed by cardiac multidetector row CT in an adolescent male with chronic migraine and stroke.

  3. Multidetector Row CT Detection of a Patent Foramen Ovale Causing Neurologic Deficits in an Adolescent: A Case Report

    International Nuclear Information System (INIS)

    Lee, Jung Bin; Kim, Dong Hun; Oh, Jae Hee; Seo, Hye Sun; Suk, Eun Ha

    2012-01-01

    A patent foramen ovale (PFO) is a persisting fetal circulation structural abnormality that can cause neurologic deficits such as migraine and cryptogenic stroke. Here we report a case of PFO diagnosed by cardiac multidetector row CT in an adolescent male with chronic migraine and stroke.

  4. [Computed tomography of the heart

    DEFF Research Database (Denmark)

    Kristensen, T.S.; Kofoed, K.F.; der, Recke P. von

    2009-01-01

    Noninvasive evaluation of the coronary arteries by multi-detector row computed tomography is a promising new alternative to conventional invasive coronary angiography. This article describes the technical background, methods, limitations and clinical applications and reviews current literature...... that compares the diagnostic accuracy of multi-detector row computed tomography with that of coronary angiography Udgivelsesdato: 2009/4/6...

  5. Evaluation of peripheral artery stent with 64-slice multi-detector row CT angiography: Prospective comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Li Xiaoming; Li Yuhua; Tian Jianming; Xiao Yi; Lu Jianping; Jing Zaiping; Sheng Jing; Edwin, Angela; Wu Fanghong

    2010-01-01

    Purpose: To assess the accuracy of 64-slice multi-detector row computed tomography (MDCT) angiography in the evaluation of peripheral artery in-stent or peristent restenosis, with conventional digital subtraction angiography (DSA) as the reference standard. Materials and methods: Forty-one patients (30 men, 11 women; mean age, 69.8 ± 9.2 years) with symptomatic peripheral arterial occlusive disease after peripheral artery stenting (81 stented lesions) underwent both conventional DSA and 64-slice MDCT angiography. Each stent was classified as evaluable or unevaluable, and every stent was divided into three segments (proximal stent, stent body, and distal stent), resulting in 243 segments. For evaluation, stenosis was graded as follows: 1, none or slight stenosis (<25%); 2, mild stenosis (25-49%); 3, moderate stenosis (50-74%); 4, severe stenosis or total occlusion (≥75%). Two readers evaluated all CT angiograms with regard to narrowing of in-stent or peristent restenosis by consensus. Results were compared with findings of the DSA. Results: Of 81 stents, 62 (76.5%) were determined to be assessable. The metal artifact of the gold marker and motion artifact increased uninterpretability of the images of stents. Overall, 24 of 28 in-stent restenosis and 38 of 53 persistent restenosis were correctly detected by MDCT (85.7% and 71.7% sensitivity). In evaluable stents, 21 of 22 in-stent restenoses and 27 of 28 persistent restenosis were correctly detected (95.4% and 96.4% sensitivity). Additionally, as the grade of stenosis increases, the mean level of CT values in the stent lumina decreases linearly accordingly. Conclusion: 64-Slice MDCT has a high accuracy for the detection of significant in-stent or peristent restenosis of assessable stents in patients with peripheral artery stent implantation and therefore can be considered as a valuable noninvasive technique for stent surveillance.

  6. Effectiveness of thin-slice axial images of multidetector row CT for visualization of bronchial artery before bronchial arterial embolization

    International Nuclear Information System (INIS)

    Shida, Yoshitaka; Hasuo, Kanehiro; Aibe, Hitoshi; Kubo, Yuko; Terashima, Kotaro; Kinjo, Maya; Kamano, H.; Yoshida, Atsuko

    2008-01-01

    We assessed the ability of visualization of bronchial artery (BA) by using thin-slice axial images of 4-detector multidetector row CT in 65 patients with hemoptysis. In all patients, the origins of BA were well identified with observation of consecutive axial images with 1 mm thickness by paging method and bronchial arterial embolization (BAE) was performed successfully. Thin-slice axial images were considered to be useful to recognize BA and to perform BAE in patients with hemoptysis. (author)

  7. Usefulness of multiplanar reformatted images of multi-detector row helical CT in assessment of biliary stent patency

    International Nuclear Information System (INIS)

    Kim, Soo Jin; Kim, Suk; Kim, Chang Won; Lee, Jun Woo; Lee, Tae Hong; Choo, Ki Seok; Koo, Young Baek; Moon, Tae Yong; Lee, Suk Hong

    2004-01-01

    To evaluate the usefulness of multi-detector row helical CT (MDCT), multiplanar reformatted images for the noninvasive assessment of biliary stent patency, and for the planning for management in patients with a sele-expandable metallic stent due to malignant biliary obstruction. Among 90 consecutive patients, from August 1999 to July 2003, 26 cases in 23 patients with malignant biliary obstruction who underwent self-expandable metaIlic stent insertion in the biliary system and percutaneous transhepatic biliary drainage within 7 days after CT were enrolled in this study. On CT images, the complete and functional obstruction of the stent and the precise level of obstruction were evaluated. The presence of an enhancing intraluminal mass or wall thickening around stent was determined, and the causes of obstruction were evaluated. These findings were then compared with percutaneous transhepatic cholangiography. Multi-detector row helical CT correctly demonstrated the patency of a stent in 24 cases (92.3%). It was adequate in helping to depict the precise level of stent occlusion in 23 cases (88.5%). Multi-detector row helical CT also revealed the extent of tumor that represented as an enhancing intraluminal mass or wall thickening around the stent in 23 cases, and this was represented as complete obstruction on percutaneous transhepatic cholangiography. In the case of functional obstruction, MDCT predicted the possible cause of the obstruction. Multiplanar reformatted images of multi-detector row helical CT is a useful imaging modality for the noninvasive assessment of stent patency and the precise level of obstruction when stent obstruction is suspected in the patients with self-expandable metallic stent due to malignant biliary obstruction. It can also predict the possible cause of the obstruction and allows adequate planning for the medical management of such cases

  8. Usefulness of multiplanar reformatted images of multi-detector row helical CT in assessment of biliary stent patency

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soo Jin; Kim, Suk; Kim, Chang Won; Lee, Jun Woo; Lee, Tae Hong; Choo, Ki Seok; Koo, Young Baek; Moon, Tae Yong; Lee, Suk Hong [Pusan National Univ. Hospital, Busan (Korea, Republic of)

    2004-08-01

    To evaluate the usefulness of multi-detector row helical CT (MDCT), multiplanar reformatted images for the noninvasive assessment of biliary stent patency, and for the planning for management in patients with a sele-expandable metallic stent due to malignant biliary obstruction. Among 90 consecutive patients, from August 1999 to July 2003, 26 cases in 23 patients with malignant biliary obstruction who underwent self-expandable metaIlic stent insertion in the biliary system and percutaneous transhepatic biliary drainage within 7 days after CT were enrolled in this study. On CT images, the complete and functional obstruction of the stent and the precise level of obstruction were evaluated. The presence of an enhancing intraluminal mass or wall thickening around stent was determined, and the causes of obstruction were evaluated. These findings were then compared with percutaneous transhepatic cholangiography. Multi-detector row helical CT correctly demonstrated the patency of a stent in 24 cases (92.3%). It was adequate in helping to depict the precise level of stent occlusion in 23 cases (88.5%). Multi-detector row helical CT also revealed the extent of tumor that represented as an enhancing intraluminal mass or wall thickening around the stent in 23 cases, and this was represented as complete obstruction on percutaneous transhepatic cholangiography. In the case of functional obstruction, MDCT predicted the possible cause of the obstruction. Multiplanar reformatted images of multi-detector row helical CT is a useful imaging modality for the noninvasive assessment of stent patency and the precise level of obstruction when stent obstruction is suspected in the patients with self-expandable metallic stent due to malignant biliary obstruction. It can also predict the possible cause of the obstruction and allows adequate planning for the medical management of such cases.

  9. Multidetector-row CT angiography of hepatic artery: comparison with conventional angiography

    International Nuclear Information System (INIS)

    Kim, Jin Woong; Jeong, Yong Yeon; Yoon, Woong; Kim, Jae Kyu; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun

    2003-01-01

    To determine the usefulness of three-dimensional CT angiography using multidetector-row CT (MD-CT) for delineating the arterial anatomy of the liver. Hepatic arterial three-dimensional CT angiography was performed using MDCT (lightspeed Qx/I; GE medical systems, milwaukee, Wis., U.S.A.) in 45 patients with HCC undergoing conventional angiography for transcatheter hepatic arterial chemoembolization. The scanning parameters during the early arterial phase were 2.5 mm slice thickness, 7.5 mm rotation of table speed, and a pitch of 3. Images were obtained by one radiologist using maximum intensity projection from axial CT images obtained during the early arterial phase. Two radiologists blinded to the findings of conventional angiography independently evaluated the hepatic arterial anatomy and the quality of the images obtained. Compared with conventional angiography, reader A correctly evaluated the hepatic arterial anatomy depicted at three-dimensional CT angiography. Reader B's evaluation was correct in 40 of 45 patients. Interobserver agreement was good (kappa value, 0.73), and both readers assessed the quality of three-dimensional CT angiography as excellent. Three-dimensional CT angiography using MDCT was accurate for delineating the arterial anatomy of the liver, and interobserver agreement was good. The modality may provide, prior to conventional angiography, valuable information regrading a patient's hepatic arterial anatomy

  10. Multidetector-row helical CT: analysis of time management and workflow

    Energy Technology Data Exchange (ETDEWEB)

    Roos, Justus E.; Desbiolles, Lotus M.; Willmann, Juergen K.; Weishaupt, Dominik; Marincek, Borut; Hilfiker, Paul R. [Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland)

    2002-03-01

    The purpose of this study was to evaluate time management and workflow for multidetector-row helical CT (MDCT). Time for patient and data handling of at total of 580 patients were evaluated at two different time periods (December 1999, August 2000), each for the following baseline measurements: (a) change of clothes/instruction; (b) patient placement on the CT table/i.v. catheter; (c) CT planning and programming; (d) CT data acquisition; (e) CT data reconstruction; (f) CT data storage/printing. All imaging was performed on a Somatom Volume Zoom (Siemens, Erlangen, Germany). Time measurements summarized for different CT protocols revealed the following: (a) 5:01 min ({+-}2.06 min); (b) 4:36 min ({+-}2.43 min); (c) 4:11 min ({+-}2.55 min); (d) 0:43 min ({+-}0.15 min); (e) 6:59 min ({+-}2.39 min); (f) 09:51 min ({+-}3.51 min). Planning and programming was most time-consuming for CT angiography, whereas chest and abdominal CT needed only 3:26 and 3:30 min, respectively. Reconstruction time was highest for HRCT (9:22 min) and CTA (9:03 min). Data storage/printing was most time-consuming for HRCT (13:02 min), followed by combined neck-chest-abdomen examinations (12:19 min). Comparing the two time periods, during which a software update was performed, a mean time reduction of 4:31 min per patient (15%, p<0.001) was achieved. Whereas CT data acquisition time is no longer a problem with MDCT, patient management, data reconstruction, and data storage are the most time-consuming parts. Well-trained technicians, state-of-the-art workstations, and fast networking are the most important factors to improve workflow. (orig.)

  11. Thin-section multiplanar reformats from multidetector-row CT data: Utility for assessment of regional tumor extent in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Higashino, Takanori; Ohno, Yoshiharu; Takenaka, Daisuke; Watanabe, Hirokazu; Nogami, Munenobu; Ohbayashi, Chiho; Yoshimura, Masahiro; Satouchi, Miyako; Nishimura, Yoshihiro; Fujii, Masahiko; Sugimura, Kazuro

    2005-01-01

    Purpose: To determine the clinical utility of thin-section multiplanar reformats (MPRs) from multidetector-row CT (MDCT) data sets for assessing the extent of regional tumors in non-small cell lung cancer (NSCLC) patients. Materials and methods: Sixty consecutive NSCLC patients, who were considered candidates for surgical treatment, underwent contrast-enhanced MDCT examinations, surgical resection and pathological examinations. All MDCT examinations were performed with a 4-detector row computed tomography (CT). From each raw CT data set, 5 mm section thickness CT images (routine CT), 1.25 mm section thickness CT images (thin-section CT) and 1.25 mm section thickness sagittal (thin-section sagittal MPR) and coronal images (thin-section coronal MPR) were reconstructed. A 4-point visual score was used to assess mediastinal, interlobar and chest wall invasions on each image set. For assessment of utility in routine clinical practice, mean reading times for each image set were compared by means of Fisher's protected least significant difference (PLSD) test. A receiver operator characteristic (ROC) analysis was performed to determine the diagnostic capability of each of the image data sets. Finally, sensitivity, specificity and accuracy of the reconstructed images were compared by McNemar test. Results: Mean reading times for thin-section sagittal and coronal MPRs were significantly shorter than those for routine CT and thin-section CT (p < 0.05). Areas under the curve (Azs) showing interlobar invasion on thin-section sagittal and coronal MPRs were significantly larger than that on routine CT (p = 0.03), and the Az on thin-section sagittal MPR was also significantly larger than that on routine CT (p = 0.02). Accuracy of chest wall invasion by thin-section sagittal MPR was significantly higher than that by routine CT (p = 0.04). Conclusion: Thin-section multiplanar reformats from multidetector-row CT data sets are useful for assessing the extent of regional tumors in non

  12. Upper abdominal gadoxetic acid-enhanced and diffusion-weighted MRI for the detection of gastric cancer: Comparison with two-dimensional multidetector row CT

    International Nuclear Information System (INIS)

    Jang, K.M.; Kim, S.H.; Lee, S.J.; Lee, M.W.; Choi, D.; Kim, K.M.

    2014-01-01

    Aim: To evaluate the diagnostic performance of abdominal magnetic resonance imaging (MRI) for the detection of gastric cancer in comparison with that of two-dimensional (2D) multidetector row computed tomography (CT). Materials and methods: The study included 189 patients with 170 surgically confirmed gastric cancers and 19 patients without gastric cancer, all of whom underwent gadoxetic acid-enhanced MRI with diffusion-weighted (DW) imaging, and multidetector contrast-enhanced abdominal CT imaging. Two observers independently analysed three sets of images (CT set, conventional MRI set, and combined conventional and DW MRI set). A five-point scale for likelihood of gastric cancer was used. Diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were evaluated. Quantitative [apparent diffusion coefficient (ADC) analyses with Mann–Whitney U-test were conducted for gastric cancers and the nearby normal gastric wall. Results: The diagnostic accuracy and sensitivity for detection of gastric cancer were significantly higher on combined conventional and DW MRI set (77.8–78.3%; 75.3–75.9%) than the CT imaging set (67.7–71.4%; 64.1–68.2%) or the conventional MRI set (72–73%; 68.8–70%; p < 0.01). In particular, for gastric cancers with pT2 and pT3, the combined conventional and DW MRI set (91.6–92.6%) yielded significantly higher sensitivity for detection of gastric cancer than did the CT imaging set (76.8–81.1%) by both observers (p < 0.01). The mean ADC of gastric cancer lesions (1 ± 0.23 × 10 −3 mm 2 /s) differed significantly from that of normal gastric wall (1.77 ± 0.25 × 10 −3  mm 2 /s; p < 0.01). Conclusion: Abdominal MRI with DW imaging was more sensitive for the detection of gastric cancer than 2D-multidetector row CT or conventional MRI alone. - Highlights: • The sensitivity for detection of gastric cancer is high on abdominal MR imaging. • DW imaging is helpful for

  13. The quality of reconstructed 3D images in multidetector-row helical CT: experimental study involving scan parameters

    International Nuclear Information System (INIS)

    Shin, Ji Hoon; Lee, Ho Kyu; Choi, Choong Gon; Suh, Dae Chul; Lim, Tae Hwan; Kang, Weechang

    2002-01-01

    To determine which multidetector-row helical CT scanning technique provides the best-quality reconstructed 3D images, and to assess differences in image quality according to the levels of the scanning parameters used. Four objects with different surfaces and contours were scanned using multidetector-row helical CT at three detector-row collimations (1.25, 2.50, 5.00 mm), two pitches (3.0, 6.0), and three different degrees of overlap between the reconstructed slices (0%, 25%, 50%). Reconstructed 3D images of the resulting 72 sets of data were produced using volumetric rendering. The 72 images were graded on a scale from 1 (worst) to 5 (best) for each of four rating criteria, giving a mean score for each criterion and an overall mean score. Statistical analysis was used to assess differences in image quality according to scanning parameter levels. The mean score for each rating criterion, and the overall mean score, varied significantly according to the scanning parameter levels used. With regard to detector-row collimation and pitch, all levels of scanning parameters gave rise to significant differences, while in the degree of overlap of reconstructed slices, there were significant differences between overlap of 0% and of 50% in all levels of scanning parameters, and between overlap of 25% and of 50% in overall accuracy and overall mean score. Among the 18 scanning sequences, the highest score (4.94) was achieved with 1.25 mm detector-row collimation, 3.0 pitch, and 50% overlap between reconstructed slices. Comparison of the quality of reconstructed 3D images obtained using multidetector-row helical CT and various scanning techniques indicated that the 1.25 mm, 3.0, 50% scanning sequence was best. Quality improved as detector-row collimation decreased; as pitch was reduced from 6.0 to 3.0; and as overlap between reconstructed slices increased

  14. Multi-detector row CT in the assessment of axillary lymph node metastasis in breast cancer

    International Nuclear Information System (INIS)

    Murakami, Shogo

    2003-01-01

    The purpose of this study is to evaluate the diagnostic capability instead of clinical efficacy of multi-detector row CT (MDCT) in the assessment of axillary lymph node metastasis in breast cancer. MDCT was performed in 63 patients with breast cancer, and multiplanar reformation (MPR) and volume rendering (VR) images were reconstructed for the evaluation of bilateral axillary lymph nodes. Two hundred sixty eight lymph nodes were depicted with MDCT, and correlation with pathological findings was performed. The short axis length of lymph node was measured on MPR image, and the shape of the nodes was analyzed with the pathological results statistically. The diagnostic criteria on size and shape of lymph node metastasis were discussed Dynamic study with contrast media was also performed, and the CT value ratios (CTVR) of the lymph nodes and breast tumors were calculated. No relevance of axillary lymph node metastasis was noted to the pathological types of breast cancer. The average short axis length of the ipsilateral axillary nodes was 8.9 mm±3.8 (SD) while that of the contralateral nodes was 4.9 mm±1.1 (SD) showing significant difference. More than 6.5 mm in short length of the lymph node was thought to be an effective criterion for positive metastasis, and its sensitivity was 96%. Soybean-shape lymph node was statistically common in metastasis, while non-metastatic nodes were commonly demonstrated as letter ''c'' shape or ring-like shape. Statistical relevance was obtained between the CTVR of axillary lymph nodes and that of breast tumors, suggesting clinical usefulness of dynamic study using contrast media in the evaluation of lymph node metastasis. With MPR and VR images using MDCT, more accurate morphological evaluation of axillary lymph nodes was possible. When soybean-shape node with more than 6.5 mm in short axis is depicted in the axillar region on MDCT metastasis should be the consideration. Comparison with the contralateral side as a control in coronal MPR image was effective in the assessment of the axillary lymph node metastasis in breast cancer. (author)

  15. Comparison of a dental cone beam CT with a multi-detector row CT on effective doses and physical image quality

    International Nuclear Information System (INIS)

    Yoshida, Yutaka; Tokumori, Kenji; Okamura, Kazutoshi; Yoshiura, Kazunori

    2011-01-01

    The purpose of this study was to compare a dental cone beam computed tomography (dental CBCT) and a multi-detector row CT (MDCT) using effective doses and physical image quality. A dental mode (D-mode) and an implant mode (I-mode) were employed for calculating effective doses. Field of view (FOV) size of the MDCT was 150 mm. Three types of images were obtained using 3 different reconstruction functions: FC1 (for abdomen images), FC30 (for internal ear and bone images) and FC81 (for high resolution images). Effective doses obtained with the D-mode and with the I-mode were about 20% and 50% of those obtained with the MDCT, respectively. Resolution properties obtained with the D-mode and I-mode were superior to that of the MDCT in a high frequency range. Noise properties of the D-mode and the I-mode were better than those with FC81. It was found that the dental CBCT has better potential as compared with MDCT in both dental and implant modes. (author)

  16. 16-slice multi-detector row CT coronary angiography: image quality and optimization of the image reconstruction window

    International Nuclear Information System (INIS)

    Kim, Yoo Kyung; Shim, Sung Shine; Lim, Soo Mee; Hwang, Ji Young; Kim, Yoon Kyung

    2005-01-01

    The purpose of this experiment is to investigate the image quality of CT coronary angiography using a 16-slice multi-detector row CT and to determine the optimal image reconstruction window. CT coronary angiography was obtained in 36 nonsymptomatic volunteers using a 16-slice multi-detector row CT (SOMATOM Sensation, Siemens Medical System). The mean heart rates were 70 beats per minute (bpm) or less in 18 persons and more than 70 bpm in 18 persons. Eleven data sets were obtained for each patient (reconstructed at 30%-80% of the cardiac cycle with an increment of 5%). Image quality of the eight coronary segments [left main coronary artery (LM), proximal and middle segments of left anterior descending artery (p-LAD, m-LAN) and left circumflex coronary artery (p-LCx, m-LCx) and proximal, middle and distal segments of right coronary artery (p-RCA, m-RCA, d-RCA)] was assessed. The optimal reconstruction windows in the cardiac cycle for the best image quality were 60-70% for the segments of the LM, LAD, and LC arteries in two groups (bpm 70) and 55-65% (bpm 70) for the segments of the RCA. On the best dataset for each coronary segment, the following diagnostic image quality was achieved in the two groups: LM: 100%, 83%; p-LAD: 100%, 88% m-LAD: 100%, 72%; p-LCx: 100%, 72%; m-LCx: 100%, 72%; p-RCA: 94%, 72%; m-RCA: 61%, 50%; d-RCA: 100%, 80%. The 16 slice multi-detector row CT scan provided visualization of the coronary arteries with high resolution. Especially in the group with a mean heart rate of 70 bpm or less, all the coronary segments except the RCA showed diagnostic image quality. Optimal image quality was achieved with a 60-70% trigger delay for all coronary arterial segments, but the best images of RCA were achieved in the earlier cardiac phase in the patients with a mean heart rate of more than 70 bpm

  17. Clinical usefulness of multidetector-row CT to evaluate coronary artery calcium score in type 2 diabetes

    International Nuclear Information System (INIS)

    Nishioka, Makiko; Sakuma, Toru; Sano, Hironari; Utsunomiya, Kazunori; Agata, Toshihiko; Shimizu, Keisuke; Tajima, Naoko

    2004-01-01

    According to recent studies, multidetector-row CT (MDCT) with a retrospective electrocardiogram (ECG)-gating reconstruction algorithm shows a high correlation with coronary artery calcium score determined using electron-beam CT. Diabetes leads to many macrovascular complications, including coronary artery disease. The aim of this study was to evaluate risk factors for cardiac macroangiopathy in type 2 diabetes using MDCT. An observational cross-sectional study was performed in 90 patients with diabetes mellitus. Coronary calcium data was acquired by MDCT (SOMATOM Volume Zoom, Siemens AG, Medical Solutions, Germany). Physical examinations, laboratory data, glycemic control, and control of other risk factors were analyzed. The coronary artery calcium score increased with age. Multivariant analysis revealed that the coronary calcium score was closely correlated with electrocardiogram evaluation and control of hypertension. Coronary artery calcium score as determined by MDCT can be used as a screening radiological examination for cardiac macroangiopathy in diabetes patients with electrocardiogram abnormality and hypertension. (author)

  18. Abdominal multi-detector row CT: Effectiveness of determining contrast medium dose on basis of body surface area

    International Nuclear Information System (INIS)

    Onishi, Hiromitsu; Murakami, Takamichi; Kim, Tonsok; Hori, Masatoshi; Osuga, Keigo; Tatsumi, Mitsuaki; Higashihara, Hiroki; Maeda, Noboru; Tsuboyama, Takahiro; Nakamoto, Atsushi; Tomoda, Kaname; Tomiyama, Noriyuki

    2011-01-01

    Purpose: To investigate the validity of determining the contrast medium dose based on body surface area (BSA) for the abdominal contrast-enhanced multi-detector row CT comparing with determining based on body weight (BW). Materials and methods: Institutional review committee approval was obtained. In this retrospective study, 191 patients those underwent abdominal contrast-enhanced multi-detector row CT were enrolled. All patients received 96 mL of 320 mg I/mL contrast medium at the rate of 3.2 mL. The iodine dose required to enhance 1 HU of the aorta at the arterial phase and that of liver parenchyma at portal venous phase per BSA were calculated (EU BSA ) and evaluated the relationship with BSA. Those per BW were also calculated (EU BW ) and evaluated. Estimated enhancement values (EEVs) of the aorta and liver parenchyma with two protocols for dose decision based on BSA and BW were calculated and patient-to-patient variability was compared between two protocols using the Levene test. Results: The mean of EU BSA and EU BW were 0.0621 g I/m 2 /HU and 0.00178 g I/kg/HU for the aorta, and 0.342 g I/m 2 /HU and 0.00978 g I/kg/HU for the liver parenchyma, respectively. In the aortic enhancement, EU BSA was almost constant regardless of BSA, and the mean absolute deviation of the EEV with the BSA protocol was significantly lower than that with the BW protocol (P < .001), although there was no significant difference between two protocols in the hepatic parenchymal enhancement (P = .92). Conclusion: For the aortic enhancement, determining the contrast medium dose based on BSA was considered to improve patient-to-patient enhancement variability.

  19. Multidetector-row computed tomography imaging of prosthetic heart valves: clinical and experimental aspects

    NARCIS (Netherlands)

    Symersky, P.

    2012-01-01

    Tot voor kort had het afbeelden van hartklepprothesen (kunstkleppen) door middel van een CT-scan geen aanvullende waarde. Kunstkleppen zijn bewegende metalen objecten, en daardoor werden CT-beelden vervormd door artefacten en dubbelcontouren. De huidige CT-systemen kunnen echter vaak wel een

  20. Multi-detector row helical CT of the liver. Quantitative assessment of iodine concentration of intravenous contrast material on multiphasic CT. A prospective randomized study

    International Nuclear Information System (INIS)

    Tsurusaki, Masakatsu; Sugimoto, Koji; Fujii, Masahiko; Sugimura, Kazuro

    2004-01-01

    The purpose of this study was to assess the quantitative effects of contrast material concentration on hepatic parenchymal and vascular enhancement in multiphasic computed tomography (CT), using multi-detector row helical CT. We designed a prospective randomized study to test two different concentrations of contrast material on five phasic scans of the liver. One hundred patients were randomly assigned to two groups: an iodine concentration of 300 mg/mL in group A and 370 mg/mL in group B. All patients received a fixed volume of 100 mL at a 4 mL/sec injection rate. Enhancement values for the hepatic parenchyma and aorta at three levels (upper, middle, and lower level of the liver), and values for portal and hepatic veins were statistically compared between the two groups. Hepatic parenchymal enhancement values at all levels of the liver in portal phase (PP) and equilibrium phase (EP) were significantly higher in group B than in group A (p<0.01). Aortic enhancement values at two levels of the liver (middle and lower) in early hepatic arterial phase (EAP) were significantly higher in group B than in group A (p<0.05), however, there was no significant difference between groups A and B in aortic enhancement during the delayed hepatic arterial phase (DAP). Portal and hepatic venous enhancement values in PP and EP were significantly higher in group B than in group A (p<0.01). On multiphasic dynamic CT, the use of a higher iodine concentration of contrast material results in higher hepatic parenchymal enhancement and aortic enhancement, as well as higher portal and hepatic venous enhancement. (author)

  1. Tracheal compression due to an elongated aortic arch in patients with congenital heart disease: evaluation using multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Noriko; Hayabuchi, Yasunobu; Inoue, Miki; Sakata, Miho; Nabo, Manal Mohamed Helmy; Nakagawa, Ryuji; Saijo, Takahiko; Kagami, Shoji [University of Tokushima, Department of Pediatrics, Tokushima (Japan)

    2009-10-15

    The airway can become obstructed as a result of compression by an elongated aortic arch. In this study we evaluated tracheal compression using multidetector-row CT in patients with congenital heart disease and an elongated aortic arch. The trachea was measured at the level of the aortic arch in 205 children and young adults and then the severity of tracheal compression was determined by measuring the tracheal diameter ratio (short axis diameter/long axis diameter). Patients were divided as follows: group I (normal aortic arch; n=166), group II (transversely running aortic arch; n=22), and group III (elongated aortic arch; n=17). From the viewpoint of the relationship of the great arteries, group II had D-malposition, and group III had L-malposition. Age, height, weight and body surface area were significantly correlated with the short and long axis diameter in group I. There was a negative correlation between tracheal diameter ratio and the physical size parameters. The tracheal diameter ratio in group III was 0.50{+-}0.13, which was significantly lower than in groups I and II (P<0.01 and 0.05, respectively). Even apparently asymptomatic patients with an elongated aortic arch can have tracheal compression. An elongated aortic arch may be a useful predictor of tracheal compression. (orig.)

  2. Multidetector-row CT of right hemidiaphragmatic rupture caused by blunt trauma: a review of 12 cases

    International Nuclear Information System (INIS)

    Rees, O.; Mirvis, S.E.; Shanmuganathan, K.

    2005-01-01

    AIM: To determine the usefulness of multidetector-row CT (MDCT) with multiplanar reformatted (MPR) images in the sagittal and coronal plane in diagnosing acute right hemidiaphragmatic rupture. MATERIALS AND METHODS: Twelve patients were identified who received chest and abdominal MDCT after major blunt trauma diagnosed with right diaphragmatic injury. Sagittal and coronal reformations were performed in all cases. The images were retrospectively reviewed by two experienced radiologists for signs of right diaphragm injury, such as direct diaphragm discontinuity, the 'collar sign', the 'dependent viscera sign', and intra-thoracic location of herniated abdominal contents. RESULTS: Of the 12 cases of right hemidiaphragm rupture, diaphragm discontinuity was seen in seven (58%) cases, the collar sign in five (42%), the dependent viscera sign in four (33%), and transdiaphragmatic herniation of the right colon and fat in another. Two variants of the collar sign were apparent on high-quality sagittal and coronal reformations. The first, termed the 'hump sign', describes a rounded portion of liver herniating through the diaphragm forming a hump-shaped mass, and the second, termed the 'band sign,' is a linear lucency across the liver along the torn edges of the hemidiaphragm. The hump sign occurred in 10 (83%) patients and the band sign in four (33%). CONCLUSION: MDCT is very useful in the diagnosis of right hemidiaphragm injury caused by blunt trauma when sagittal and coronal reformatted images are obtained, and should allow more frequent preoperative diagnosis

  3. Clinical assessment of hypopharyngeal and laryngeal disorders by three-dimensional multidetector-row CT. Feasibility of imaging during phonation

    International Nuclear Information System (INIS)

    Tan, Xiaotian

    2002-01-01

    The hypopharynx and larynx can adapt their structures to physiological functions. To clarify the relation between morphologic changes and the development of pharyngeal and laryngeal disorders, images of the hypopharynx and larynx were obtained by multidetector-row CT (MD-CT) during phonation and quiet breathing. The clinical usefulness of such imaging study was assessed by comparing the images taken in the two phases. The study included 23 subjects, 20 patients with a hypopharyngeal or laryngeal disorder and 3 healthy volunteers. MD-CT scanning of the hypopharynx and larynx was not influenced by breathing and body movement. The volume rendering (VR) method was useful in that three-dimensional imaging could visualize the internal structure of the hypopharynx and larynx. Thus, the volume rendering method can be regarded as a virtual three-dimensional method. The normal anatomic structure of the hypopharynx and larynx were depicted in full and three-dimensionally. The extent of hypopharyngeal and laryngeal cancer was shown clearly. Edema due to paralysis of recurrent nerve was demonstrated in full and three-dimensionally, providing for functional diagnosis. In the case of mucosal edema caused by trauma, the extent of the edema and its effect on the airway were clearly observed. These results suggest that MD-CT with three-dimensional imaging during phonation is useful in the diagnosis of hypopharyngeal and laryngeal disorders. (author)

  4. Three-dimensional reconstructions of the orbital floor by volume-rendering of multidetector-row CT data

    International Nuclear Information System (INIS)

    Yoshikawa, Tetsuya; Miyajima, Akira; Fujita, Yuko; Yamada, Kazuo

    2011-01-01

    The advent of 3D-CT has made the evaluation of complicated facial fractures much easier than before. However, its use in injuries involving the orbital floor has been limited by the difficulty of visualizing the thin bony structures given artifacts caused by the partial volume effect. Nevertheless, high-technology machines such as multidetector-row CT (MDCT) and new-generation software have improved the quality of 3D imaging, and this paper describes a procedure for obtaining better visualization of the orbital floor using a MDCT scanner. Forty trauma cases were subject to MDCT: 13 with injury to the orbital floor, and 27 without. All scans were performed in the standard manner, at slice thicknesses of 0.5 mm. 3D-CT images were created overlooking the orbital floor including soft tissue to minimize the pseudo-foramen artifacts produced through volume rendering. Bone deficits, fracture lines, and grafted bone were visible in the 3D images, and visualization was supported by the ready creation of stereoscopic images from MDCT volume data. Measurement of the pseudo-foramen revealed approximately half the artifacts to be less than 5 mm in diameter, suggesting practicality of this method without subjecting the patient to undue increases in radiation exposure in the treatment of cases involving injury to the orbital floor. (author)

  5. Multi-detector row CT of the kidney: Optimizing scan delays for bolus tracking techniques of arterial, corticomedullary, and nephrographic phases

    Energy Technology Data Exchange (ETDEWEB)

    Goshima, Satoshi [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Kanematsu, Masayuki [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Department of Radiology Services, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Nishibori, Hironori; Kondo, Hiroshi; Tsuge, Yusuke [Department of Radiology, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Yokoyama, Ryujiro; Miyoshi, Toshiharu [Department of Radiology Services, Gifu University School of Medicine, 1-1 Yanagido, Gifu 501-1193 (Japan); Onozuka, Minoru [Department of Physiology and Neuroscience, Kanagawa Dental College, Yokosuka, Kanagawa (Japan); Shiratori, Yoshimune [Department of Medical Informatics, Gifu University School of Medicine, Gifu (Japan); Moriyama, Noriyuki [Department of Diagnostic Radiology, National Cancer Center Hospital, Tsukiji, Chuo-Ku, Tokyo (Japan); Bae, Kyongtae T. [Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO (United States)

    2007-09-15

    Purpose: To determine optimal scan delays for renal arterial-, corticomedullary-, and nephrographic-phase imaging with multi-detector row computed tomography (MDCT) of the kidney using a bolus-tracking technique. Methods and materials: One hundred and twenty-eight patients underwent three-phase CT scan of the kidney with eight-row MDCT after receiving 2 mL/kg of 300 mg I/mL contrast medium at 4 mL/s. Patients were prospectively randomized into three groups with different scan delays for the three scan phases (arterial, corticomedullary, and nephrographic) after bolus-tracking triggered at 50 HU of aortic contrast enhancement: group 1 (5, 20, 45 s); group 2 (10, 25, 50 s); and group 3 (15, 30, 55 s). Mean CT values (HU) of the abdominal aorta, renal artery, renal vein, renal cortex, and renal medulla were measured; increases in CT values pre- to post-contrast were assessed as contrast enhancement. Renal artery-to-vein and renal cortex-to-medulla contrast differences were also assessed. Qualitative analysis was also performed. Results: Mean renal artery enhancement was 240-288 HU at 5-15 s after the trigger and peaked at 10 s (P < .001). Mean renal cortical enhancement was 195-217 HU at 10-30 s and peaked at 25 s (P < .01). Contrast enhancement in the renal medulla increased gradually and reached mean 145 HU at 55 s. Cortex-to-medulla contrast difference was high (110-140 HU) at 5-30 s and decreased below 30 HU at 45 s after the trigger. Renal artery-to-vein contrast difference was high (121-125 HU) at 5-10 s. Qualitative results correlated well with quantitative results. Conclusion: For the injection protocol used in this study, optimal scan delays after the bolus-tracking trigger were 5-10 s for renal arterial, 15-25 s for corticomedullary, and 50-55 s for nephrographic phases.

  6. Assessment of vertebral artery stents using 16-slice multi-detector row CT angiography in vivo evaluation: Comparison of a medium-smooth kernel and a sharp kernel

    International Nuclear Information System (INIS)

    Yoo, Won Jong; Lim, Yeon Soo; Ahn, Kook Jin; Choi, Byung Gil; Kim, Ji Young; Kim, Sung Hoon

    2009-01-01

    Objectives: To assess the lumen visibility of extracranial vertebral artery stents examined with 16-slice multi-detector row computed tomography (MDCT) angiography in vivo using a medium-smooth kernel (B30s) and a sharp kernel (B60s), and to compare these with digital subtraction angiography (DSA) after stent placement. Methods: Twenty stents from 20 patients (14 men, 6 women; mean age, 62.7 ± 10.1 years) who underwent CT angiography (CTA) with 16-slice MDCT were retrospectively analyzed. In CT angiograms using a B30s and a B60s, the lumen diameters and CT attenuations of the stented vessels were measured three times by three observers, and artificial luminal narrowing (ALN) was calculated. To assess measurement reliability on CT angiograms, the intraclass correlation coefficient (ICC) was used. DSA served as the reference standard for the in-stent luminal measurements on CT angiography. The median interval between CT angiography and DSA was 1 day (range 1-10). Results: For interobserver reliability, intraclass correlation coefficients for the lumen diameters on CT angiograms with a B30s and a B60s were 0.90 and 0.96, respectively. The lumen diameters on CT angiograms using a B30s were consistently smaller than that on CT angiograms using a B60s (p < 0.01). The mean ALN was 37 ± 7% on CT angiograms using a B30s and 25 ± 9% on CT angiograms using a B60s. The mean CT attenuation in in-stent lumen was 347 ± 55 HU on CT angiograms using a B30s and 295 ± 46 HU on CT angiograms using a B60s. The ALN and CT attenuation within the stented vessels between CT angiograms using a B30s and a B60s was significant (p < 0.01). Conclusions: 16-slice MDCT using a sharp kernel allows good visualization of the stented vessels and is useful in the assessment of vertebral artery stent patency after stent placement.

  7. Multidetector row CT angiography of living related renal donors: Is there a need for venous phase imaging?

    International Nuclear Information System (INIS)

    Namasivayam, Saravanan; Kalra, Mannudeep K.; Waldrop, Sandra M.; Mittal, Pardeep K.; Small, William C.

    2006-01-01

    Objective: To prospectively evaluate whether renal venous anatomy can be detected from arterial phase images of multidetector row CT (MDCT) of renal donors. Material and methods: Institutional review board approved our study protocol with waiver of consent. Forty-eight consecutive renal donors (age range, 21-56 years; M:F, 20:28) referred for MDCT evaluation were included. Two sub-specialty radiologists performed an independent and separate evaluation of renal venous anatomy in arterial and venous phase images. Opacification of renal venous structures was scored on a five-point scale (1-not seen; 3-minimal opacification; 5-excellent opacification). Arterial and venous phase opacification scores were compared by Wilcoxon signed rank test. Results: Both readers detected all renal venous anomalies in arterial as well as venous phase images. Each reader detected accessory right renal veins (n = 14), retroaortic left renal vein (n = 2), circumaortic left renal vein (n = 1), and left renal hilar arteriovenous malformation (n = 1) in arterial phase images. Retroaortic left renal venous branch was difficult to differentiate from lumbar vein (reader-1, n = 1; reader-2, n = 2) in both arterial and venous phase images. Sensitivity of detection of renal veins, left adrenal, gonadal and lumbar veins in arterial phase images was 100, 83-88, 100, and 85-90%, respectively. As expected, venous phase images showed significantly greater opacification of renal veins, left gonadal, adrenal and lumbar veins (p < .05). However, this did not substantially limit the evaluation of renal venous anatomy in arterial phase images. Both readers had substantial interobserver agreement (kappa coefficient, 0.7; p < 0.05). Conclusions: Arterial phase MDCT images alone can be used to detect renal venous anomalies, and to identify small left renal venous branches namely, the left gonadal, adrenal and lumbar veins in renal donors. Venous phase MDCT acquisition is not necessary for evaluation of renal

  8. Multidetector row CT angiography of living related renal donors: Is there a need for venous phase imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Namasivayam, Saravanan [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Kalra, Mannudeep K. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Waldrop, Sandra M. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Mittal, Pardeep K. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Small, William C. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States)]. E-mail: wsmall@emory.edu

    2006-09-15

    Objective: To prospectively evaluate whether renal venous anatomy can be detected from arterial phase images of multidetector row CT (MDCT) of renal donors. Material and methods: Institutional review board approved our study protocol with waiver of consent. Forty-eight consecutive renal donors (age range, 21-56 years; M:F, 20:28) referred for MDCT evaluation were included. Two sub-specialty radiologists performed an independent and separate evaluation of renal venous anatomy in arterial and venous phase images. Opacification of renal venous structures was scored on a five-point scale (1-not seen; 3-minimal opacification; 5-excellent opacification). Arterial and venous phase opacification scores were compared by Wilcoxon signed rank test. Results: Both readers detected all renal venous anomalies in arterial as well as venous phase images. Each reader detected accessory right renal veins (n = 14), retroaortic left renal vein (n = 2), circumaortic left renal vein (n = 1), and left renal hilar arteriovenous malformation (n = 1) in arterial phase images. Retroaortic left renal venous branch was difficult to differentiate from lumbar vein (reader-1, n = 1; reader-2, n = 2) in both arterial and venous phase images. Sensitivity of detection of renal veins, left adrenal, gonadal and lumbar veins in arterial phase images was 100, 83-88, 100, and 85-90%, respectively. As expected, venous phase images showed significantly greater opacification of renal veins, left gonadal, adrenal and lumbar veins (p < .05). However, this did not substantially limit the evaluation of renal venous anatomy in arterial phase images. Both readers had substantial interobserver agreement (kappa coefficient, 0.7; p < 0.05). Conclusions: Arterial phase MDCT images alone can be used to detect renal venous anomalies, and to identify small left renal venous branches namely, the left gonadal, adrenal and lumbar veins in renal donors. Venous phase MDCT acquisition is not necessary for evaluation of renal

  9. Detection of intracranial aneurysms using three-dimensional multidetector-row CT angiography: Is bone subtraction necessary?

    International Nuclear Information System (INIS)

    Hwang, Seung Bae; Kwak, Hyo Sung; Han, Young Min; Chung, Gyung Ho

    2011-01-01

    Purpose: The aim of this study was to evaluate the usefulness of three-dimensional CT angiography (3D CTA) with bone subtraction in a comparison with 3D CTA without bone subtraction for the detection of intracranial aneurysms. Materials and methods: Among 337 consecutive patients who had intracranial aneurysms detected on 3D CTA, 170 patients who underwent digital subtraction angiography (DSA) were included in the study. CTA was performed with a 16-slice multidetector-row CT (MDCT) scanner. We created the 3D reconstruction images with and without bone subtraction by using the volume rendering technique. Three neuroradiologists in a blinded fashion interpreted both 3D CTA images with and without bone subtraction. The diagnostic accuracy of both techniques was evaluated using the alternative free-response receiver operating characteristic (ROC) analysis. The sensitivity and positive predictive value were also evaluated. Results: A total of 200 aneurysms (size: 2-23 mm) were detected in 170 patients. The area under the receiver operating characteristic curve (Az) for 3D CTA with bone subtraction (mean, Az = 0.933) was significantly higher than that for 3D CTA without bone subtraction (mean, Az = 0.879) for all observers (P < 0.05). The sensitivity of 3D CTA with bone subtraction for three observers was 90.0, 92.0 and 92.5%, respectively, while the sensitivity of 3D CTA without bone subtraction was 83.5, 83.5 and 87.5%, respectively. No significant difference in positive predictive value was observed between the two modalities. Conclusions: 3D CTA with bone subtraction showed significantly higher diagnostic accuracy for the detection of intracranial aneurysms as compared to 3D CTA without bone subtraction.

  10. Hereditary haemorrhagic telangiectasia: study of hepatic vascular alterations with multi-detector row helical CT and reconstruction programs

    International Nuclear Information System (INIS)

    Memeo, Maurizio; Stabile Ianora, Amato Antonio; Scaldapane, Arnaldo; Rotondo, Antonio; Angelelli, Giuseppe; Suppressa, Patrizia; Cirulli, Anna; Sabba', Carlo

    2005-01-01

    Purpose: To evaluate hepatic alterations in patients affected by Hereditary Haemorrhagic Telangiectasia (HHT) by using multidetector row helical CT (MDCT) and new reconstruction programs. Materials and methods: An MDCT multiphasic study of the liver was performed in 105 consecutive patients: 89 considered to be affected by HHT and 16 with suspicion of disease alone. The scan delay was determined by using a test bolus of contrast material. The CT examination was performed with a triphasic technique (double arterial phase and portal venous phase). multiplanar and angiographic reconstructions were then obtained, and the images checked for the presence of shunts, hepatic perfusion disorders, vascular lesions (telangiectasis and large confluent vascular masses), indirect signs of portal hypertension, and anatomical vascular variants. Results: Hepatic vascular alterations were found in 78/105 cases (67/89) patients affected by HHT and 11/16 patients with clinical suspicion alone). Therefore HHT diagnosis was excluded in 5 patients. 78/100 (78%) patients with HHT had intrahepatic vascular alterations: arterioportal shunts in 40/78 (51.2%) arteriosystemic shunts in 16/78 (20.5%) and both shunt types in 22/78 (28.3%). Intraparenchymal perfusion disorders were found in 46/78 (58.9%) patients. Telangiectasis were recognised in 50/78 (64.1%) patients. Large confluent vascular masses (LCVMs) were identified in 20/78 (25.6%) patients. indirect signs of portal hypertension were found in 46/78 (58.9%) cases. Variant hepatic arterial anatomy was present in 38/100 cases (38%). Conclusions: Multiphasic MDCT and the new reconstruction programs enable the identification and characterisation of the complex vascular alterations typical of HHT [it

  11. How accurate is unenhanced multidetector-row CT (MDCT) for localization of renal calculi?

    International Nuclear Information System (INIS)

    Goetschi, Stefan; Umbehr, Martin; Ullrich, Stephan; Glenck, Michael; Suter, Stefan; Weishaupt, Dominik

    2012-01-01

    Purpose: To investigate the correlation between unenhanced MDCT and intraoperative findings with regard to the exact anatomical location of renal calculi. Design, setting, and participants: Fifty-nine patients who underwent unenhanced MDCT for suspected urinary stone disease, and who underwent subsequent flexible ureterorenoscopy (URS) as treatment of nephrolithiasis were included in this retrospective study. All MDCT data sets were independently reviewed by three observers with different degrees of experience in reading CT. Each observer was asked to indicate presence and exact anatomical location of any calcification within pyelocaliceal system, renal papilla or renal cortex. Results were compared to intraoperative findings which have been defined as standard of reference. Calculi not described at surgery, but present on MDCT data were counted as renal cortex calcifications. Results: Overall 166 calculi in 59 kidneys have been detected on MDCT, 100 (60.2%) were located in the pyelocaliceal system and 66 (39.8%) in the renal parenchyma. Of the 100 pyelocaliceal calculi, 84 (84%) were correctly located on CT data sets by observer 1, 62 (62%) by observer 2, and 71 (71%) by observer 3. Sensitivity/specificity was 90–94% and 50–100% if only pyelocaliceal calculi measuring >4 mm in size were considered. For pyelocaliceal calculi ≤4 mm in size diagnostic performance of MDCT was inferior. Conclusion: Compared to flexible URS, unenhanced MDCT is accurate for distinction between pyelocaliceal calculi and renal parenchyma calcifications if renal calculi are >4 mm in size. For smaller renal calculi, unenhanced MDCT is less accurate and distinction between a pyelocaliceal calculus and renal parenchyma calcification is difficult.

  12. Integrated cardio-thoracic imaging with ECG-Gated 64-slice multidetector-row CT: initial findings in 133 patients

    International Nuclear Information System (INIS)

    Salem, Randa; Remy-Jardin, Martine; Delhaye, Damien; Khalil, Chadi; Teisseire, Antoine; Remy, Jacques; Delannoy-Deken, Valerie; Duhamel, Alain

    2006-01-01

    The purpose of this study was to investigate the possibility of assessing the underlying respiratory disease as well as cardiac function during ECG-gated CT angiography of the chest with 64-slice multidetector-row CT (MDCT). One hundred thirty-three consecutive patients in sinus rhythm with known or suspected ventricular dysfunction underwent an ECG-gated CT angiographic examination of the chest without β-blockers using the following parameters: (1) collimation: 32 x 0.6 mm with z-flying focal spot for the acquisition of 64 overlapping 0.6-mm slices (Sensation 64; Siemens); rotation time: 0.33 s; pitch: 0.3; 120 kV; 200 mAs; ECG-controlled dose modulation (ECG-pulsing) and (2) 120 ml of a 35% contrast agent. Data were reconstructed: (1) to evaluate the underlying respiratory disease (1-mm thick lung and mediastinal scans reconstructed at 55% of the R-R interval; i.e., ''morphologic scans'') and (2) to determine right (RVEF) and left (LVEF) ventricular ejection fractions (short-axis systolic and diastolic images; Argus software; i.e., ''functional scans''). The mean heart rate was 73 bpm (range: 42-120) and the mean scan time was 18.11±2.67 s (range: 10-27). A total of 123 examinations (92%) had both lung and mediastinal images rated as diagnostic scans, whereas 10 examinations (8%) had non-diagnostic images altered by the presence of respiratory-motion artifacts (n=4) or cyclic artifacts related to the use of a pitch value of 0.3 in patients with a very low heart rate during data acquisition (n=6). Assessment of right and left ventricular function was achievable in 124 patients (93%, 95% CI: 88-97%). For these 124 examinations, the mean RVEF was 46.10% (±9.5; range: 20-72) and the mean LVEF was 58.23% (±10.88; range: 20-83). In the remaining nine patients, an imprecise segmentation of the right and left ventricular cavities was considered as a limiting factor for precise calculation of end-systolic and end-diastolic ventricular volumes. The mean (±SD) DLP

  13. Advanced Gastric Cancer: Differentiation of Borrmann Type IV versus Borrmann Type III by Two-Phased Dynamic Multi-Detector Row CT with Use of the Water Filling Method

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Jung; Yu, Jeong Sik; Lee, Sang Min; Kim, Joo Hee; Chung, Jae Joon; Kim, Ki Whang [Dept. of Radiology, Yonsei University College of Medicine, Gangnam Severance Hospital, Seoul (Korea, Republic of); Kang, Hae Youn [CHA Bundang Medical Center, CHA University, Seongnam (Korea, Republic of)

    2013-02-15

    To characterize Borrmann type IV from Borrmann type III advanced gastric cancer (AGC) by two-phased multi-detector row computed tomography (MDCT) using the water filling method. A total of 143 patients (pathologically confirmed Borrmann type III and IV - 100 and 43 patients), who underwent preoperative MDCT, were enrolled. Two radiologists, retrospectively and independently, determined tumor enhancement pattern using a 5-grade scale without clinical information. A weighted kappa test was applied for interobserver variability. The score of tumor enhancement pattern correlated with Borrmann type as determined by Spearman's correlation coefficient. The accuracy of differentiation of Borrmann type using MDCT was determined by receiver operating characteristic curves. Interobserver agreement (weighted kappa = 0.683) was substantial. The tumor enhancement pattern score showed a significant correlation with Borrmann type (reviewer 1, r = 0.591, p < 0.001; reviewer 2, r = 0.616, p < 0.001). The accuracy for differentiation of Borrmann type on MDCT was 0.86 (p < 0.001) in both reviewers. The sensitivity and specificity of the diagnosis of Borrmann type IV were 79% and 82% in reviewer 1, and 88% and 78% in reviewer 2, respectively. Dual-phased MDCT using the water filling method can differentiate between Borrmann type IV and III AGC with high accuracy.

  14. Utility of multidetector row computed tomography and virtual bronchoscopy in evaluation of hemoptysis due to lung cancer

    Directory of Open Access Journals (Sweden)

    Sherif A.A. Mohamed

    2016-01-01

    Conclusion: MDCT angiography is a useful and non invasive method that allows a rapid and detailed identification of abnormal vasculature responsible for hemoptysis in patients with lung cancer. MDCT-generated virtual bronchoscopy is an accurate, and non invasive method for evaluating obstructions, endoluminal masses, and external compressions in patients with hemoptysis due to lung cancer.

  15. COMPUTERS IN SURGERY

    African Journals Online (AJOL)

    BODE

    Key words: Computers, surgery, applications. Introduction ... With improved memory, speed and processing power in an ever more compact ... with picture and voice embedment to wit. With the ... recall the tedium of anatomy, physiology and.

  16. Image quality of high-resolution CT with 16-channel multidetector-row CT. Comparison between helical scan and conventional step-shoot scan

    International Nuclear Information System (INIS)

    Sumikawa, Hiromitsu; Johkoh, Takeshi; Koyama, Mitsuhiro

    2005-01-01

    The aim of this study was to evaluate the image quality of high-resolution CT (HRCT) reconstructed from volumetric data with 16-channel multidetector-row CT (MDCT). Eleven autopsy lungs that were diagnosed histopathologically were scanned by 16-channel MDCT with the step-and-shoot scan mode and three helical scan modes. Each helical mode had each size of focal spot, pitch, and time of gantry rotation. HRCT images were reconstructed from the volumetric data with each helical mode and axial sequence data. Two observers evaluated the image quality and noted the most appropriate diagnosis for each imaging. Visualization of abnormal structures with one helical mode was equal to those with axial mode, whereas those with the other two helical modes were inferior to those with axial mode (Wilcoxon signed rank test; p<0.0001). There was no significant difference in diagnostic efficacy between modes. The image quality of HRCT with appropriate helical mode is equal to that with axial mode and diagnostic efficacy is equal among all modes. These results may indicate that sufficient HRCT images can be obtained by only one helical scan without the addition of conventional axial scans. (author)

  17. Mediastinal and hilar lymphadenopathy: cross-referenced anatomy on axial and coronal images displayed by using multi-detector row CT

    International Nuclear Information System (INIS)

    Lee, Ju Hyun; Lee, Kyung Soo; Kim, Tae Sung; Yi, Chin A; Cho, Jae Min; Lee, Min Hee

    2003-01-01

    The accurate evaluation of mediastinal and pulmonary hilar lymphadenopathy, especially in patients with lung cancer, is important for determining treatment options and evaluating the response to therapy. To indicate nodal location in detail, mediastinal and hilar lymph nodes have been assigned to one of 14 nodal stations. Mediastinal nodes of greater than 10 mm short-axis diameter are regarded as abnormal, irrespective of their nodal station, while hilar nodes are considered abnormal if their diameter is greater than 10 mm in any axis or they are convex compared to surrounding lung. By providing multiplanar images, multi-detector row CT allows detailed evaluation of thoracic anatomic structures more easily than in the past, when axial images only were available. At cross-referenced imaging, a lymph node depicted at axial imaging in one anatomical location can be visualized simultaneously and automatically at coronal imaging at the exactly corresponding anatomical location. Cross-referenced coincidental axial and coronal images help assess both the size and morphology of mediastinal and hilar lymph nodes

  18. Missed rib fractures on evaluation of initial chest CT for trauma patients: pattern analysis and diagnostic value of coronal multiplanar reconstruction images with multidetector row CT.

    Science.gov (United States)

    Cho, S H; Sung, Y M; Kim, M S

    2012-10-01

    The objective of this study was to review the prevalence and radiological features of rib fractures missed on initial chest CT evaluation, and to examine the diagnostic value of additional coronal images in a large series of trauma patients. 130 patients who presented to an emergency room for blunt chest trauma underwent multidetector row CT of the thorax within the first hour during their stay, and had follow-up CT or bone scans as diagnostic gold standards. Images were evaluated on two separate occasions: once with axial images and once with both axial and coronal images. The detection rates of missed rib fractures were compared between readings using a non-parametric method of clustered data. In the cases of missed rib fractures, the shapes, locations and associated fractures were evaluated. 58 rib fractures were missed with axial images only and 52 were missed with both axial and coronal images (p=0.088). The most common shape of missed rib fractures was buckled (56.9%), and the anterior arc (55.2%) was most commonly involved. 21 (36.2%) missed rib fractures had combined fractures on the same ribs, and 38 (65.5%) were accompanied by fracture on neighbouring ribs. Missed rib fractures are not uncommon, and radiologists should be familiar with buckle fractures, which are frequently missed. Additional coronal imagescan be helpful in the diagnosis of rib fractures that are not seen on axial images.

  19. Retrospectively ECG-gated multi-detector row CT of the chest: does ECG-gating improve three-dimensional visualization of the bronchial tree?

    International Nuclear Information System (INIS)

    Schertler, T.; Wildermuth, S.; Willmann, J.K.; Crook, D.W.; Marincek, B.; Boehm, T.

    2004-01-01

    Purpose: To determine the impact of retrospectively ECG-gated multi-detector row CT (MDCT) on three-dimensional (3D) visualization of the bronchial tree and virtual bronchoscopy (VB) as compared to non-ECG-gated data acquisition. Materials and Methods: Contrast-enhanced retrospectively ECG-gated and non-ECG-gated MDCT of the chest was performed in 25 consecutive patients referred for assessment of coronary artery bypass grafts and pathology of the ascending aorta. ECG-gated MDCT data were reconstructed in diastole using an absolute reverse delay of -400 msec in all patients. In 10 patients additional reconstructions at -200 msec, -300 msec, and -500 msec prior to the R-wave were performed. Shaded surface display (SSD) and virtual bronchoscopy (VB) for visualization of the bronchial segments was performed with ECG-gated and non-ECG-gated MDCT data. The visualization of the bronchial tree underwent blinded scoring. Effective radiation dose and signal-to-noise ratio (SNR) for both techniques were compared. Results: There was no significant difference in visualizing single bronchial segments using ECG-gated compared to non-ECG-gated MDCT data. However, the total sum of scores for all bronchial segments visualized with non-ECG-gated MDCT was significantly higher compared to ECG-gated MDCT (P [de

  20. Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility

    International Nuclear Information System (INIS)

    Lee, Tain; Tsai, I.C.; Chen, Min-Chi; Fu, Yun-Ching; Jan, Sheng-Lin; Wang, Chung-Chi; Chang, Yen

    2006-01-01

    Echocardiography is the first-line modality for the investigation of neonatal congenital heart disease. Diagnostic cardiac catheterization, which has a small but recognized risk, is usually performed if echocardiography fails to provide a confident evaluation of the lesions. To verify the technical and clinical feasibilities of replacing diagnostic cardiac catheterization with multidetector-row CT (MDCT) in neonatal complex congenital heart disease. Over a 1-year period we prospectively enrolled all neonates with complex congenital heart disease referred for diagnostic cardiac catheterization after initial assessment by echocardiography. MDCT was performed using a 40-detector-row CT scanner with dual syringe injection. A multidisciplinary congenital heart disease team evaluated the MDCT images and decided if further diagnostic cardiac catheterization was necessary. The accuracy of MDCT in detecting separate cardiovascular anomalies and bolus geometry of contrast enhancement were calculated. A total of 14 neonates were included in the study. No further diagnostic cardiac catheterization was needed in any neonate. The accuracy of MDCT in diagnosing separate cardiovascular anomalies was 98% (53/54) with only one atrial septal defect missed in a patient with coarctation syndrome. The average cardiovascular enhancement in evaluated chambers was 471 HU. No obvious beam-hardening artefact was observed. The technical and clinical feasibility of MDCT in complex congenital heart disease in neonates is confirmed. After initial assessment with echocardiography, MDCT could probably replace diagnostic cardiac catheterization for further anatomical clarification in neonates. (orig.)

  1. Volume-rendered hemorrhage-responsible arteriogram created by 64 multidetector-row CT during aortography: utility for catheterization in transcatheter arterial embolization for acute arterial bleeding.

    Science.gov (United States)

    Minamiguchi, Hiroki; Kawai, Nobuyuki; Sato, Morio; Ikoma, Akira; Sanda, Hiroki; Nakata, Kouhei; Tanaka, Fumihiro; Nakai, Motoki; Sonomura, Tetsuo; Murotani, Kazuhiro; Hosokawa, Seiki; Nishioku, Tadayoshi

    2014-01-01

    Aortography for detecting hemorrhage is limited when determining the catheter treatment strategy because the artery responsible for hemorrhage commonly overlaps organs and non-responsible arteries. Selective catheterization of untargeted arteries would result in repeated arteriography, large volumes of contrast medium, and extended time. A volume-rendered hemorrhage-responsible arteriogram created with 64 multidetector-row CT (64MDCT) during aortography (MDCTAo) can be used both for hemorrhage mapping and catheter navigation. The MDCTAo depicted hemorrhage in 61 of 71 cases of suspected acute arterial bleeding treated at our institute in the last 3 years. Complete hemostasis by embolization was achieved in all cases. The hemorrhage-responsible arteriogram was used for navigation during catheterization, thus assisting successful embolization. Hemorrhage was not visualized in the remaining 10 patients, of whom 6 had a pseudoaneurysm in a visceral artery; 1 with urinary bladder bleeding and 1 with chest wall hemorrhage had gaze tamponade; and 1 with urinary bladder hemorrhage and 1 with uterine hemorrhage had spastic arteries. Six patients with pseudoaneurysm underwent preventive embolization and the other 4 patients were managed by watchful observation. MDCTAo has the advantage of depicting the arteries responsible for hemoptysis, whether from the bronchial arteries or other systemic arteries, in a single scan. MDCTAo is particularly useful for identifying the source of acute arterial bleeding in the pancreatic arcade area, which is supplied by both the celiac and superior mesenteric arteries. In a case of pelvic hemorrhage, MDCTAo identified the responsible artery from among numerous overlapping visceral arteries that branched from the internal iliac arteries. In conclusion, a hemorrhage-responsible arteriogram created by 64MDCT immediately before catheterization is useful for deciding the catheter treatment strategy for acute arterial bleeding.

  2. Detection of the anatomic structure and pathology in animal lung specimens: comparison of micro CT and multi-detector row CT

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Kun Young [National Cancer Center, Goyang (Korea, Republic of); Lee, Hyun Ju; Lee, Chang Hyun; Son, Kyu Ri; Goo, Jin Mo; Im, Jung Gi [Seoul National University Hospital and the Institute of Radiation Medicine, Seoul (Korea, Republic of); Seo, Joon Beom [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2006-05-15

    We wanted to compare the capability of micro CT and the clinically available thin-slice multi-detector row CT (MDCT) for demonstrating fine anatomic structures and pathological lesions in formalin-fixed lung specimens. The porcine lung with shark liver oil-induced lipoid pneumonia and the canine lung with pulmonary paragonimiasis were fixed by ventilating them with formalin vapor, and they were then sliced into one-centimeter thick sections. Micro CT (section thickness, 18 micrometer) and MDCT (section thickness, 0.75 mm) images were acquired in four of the lung slices of the lipoid pneumonia specimen and in five of the lung slices of the paragonimiasis specimen. On 62 pairs of micro CT and MDCT images, 169 pairs of rectangular ROIs were manually drawn in the corresponding locations. Two chest radiologists recorded the detectability of three kinds of anatomic structures (lobular core structure, interlobular septum and small bronchiolar lumen) and two kinds of pathological lesions (ground-glass opacity and consolidation) with using a five-point scale. The statistical comparison was performed by using the Wilcoxon signed rank test. Interobserver agreement was evaluated with kappa statistics. For all observers, all the kinds of anatomic structures and pathological lesions were detected better on the micro CT images than on the MDCT images ({rho} < 0.01). Agreement was fair between two observers ({kappa} = 0.38, {rho} < 0.001). The fine anatomic structures and pathological lesions of the lung were more accurately demonstrated on micro CT than on thin-slice MDCT in the inflated and fixed lung specimens.

  3. Acute pulmonary embolism: prediction of cor pulmonale and short-term patient survival from assessment of cardiac dimensions in routine multidetector-row CT

    International Nuclear Information System (INIS)

    Engeike, C.; Rummeny, E.; Marten, K.

    2006-01-01

    Purpose: evaluation of the prognostic value of morphological cardiac parameters in patients with suspected and incidental acute pulmonary embolism (PE) using multidetector-row chest CT (MSCT). Materials and methods: 2335 consecutive MSCT scans were evaluated for the presence of PE. The arterial enhancement and analysability of pulmonary arteries and the heart were assessed as parameters of the scan quality. The diastolic right and left ventricular short axes (RV D , LV D ) and the interventricular septal deviation (ISD) were measured in all PE-positive patients and the echocardiography reports were reviewed. The clinical data assessment included cardio-respiratory and other co-morbidities, systemic anticoagulant therapy (ACT), and the 30-day outcome. Predictors of acute cor pulmonale and the short-term outcome were calculated by univariate and multivariate logistic regressions including odds ratios (OR) and ROC analyses using positive (PPV) and negative predictive values (NPV). Results: 90 patients with acute PE were included (36 with clinically suspected PE, 54 with incidental PE). 26 patients had cardio-respiratory co-morbidities. Four patients underwent systemic thrombolysis, 43 underwent anticoagulation in therapeutic doses, 19 underwent anticoagulation in prophylactic doses, and 24 patients did not undergo ACT. 15 of 41 patients had echocardiographic evidence of acute cor pulmonale. 8 patients died within 30 days. The RV D was the best independent predictor of acute cor pulmonale (p = 0,002, OR = 9.16, PPV = 0.68, NPV=1 at 4.49 cm cut off) and short-term outcome (p= 0,0005, OR = 2.82, PPV = 0.23, NPV = 0.98 at 4.75 cm cut off). The RV D /LV D ratio had a PPV of 0.85 for cor pulmonale. (orig.)

  4. 64-Slice multidetector row CT angiography of the abdomen: comparison of low versus high concentration iodinated contrast media in a porcine model

    Science.gov (United States)

    Holalkere, N-S; Matthes, K; Kalva, S P; Brugge, W R; Sahani, D V

    2011-01-01

    Objective In this study we aimed to assess the image quality and degree of vascular enhancement using low-concentration contrast media (LCCM) (300 mg I ml–1) and high-concentration contrast media (HCCM) (370 mg I ml–1) on 64-slice multidetector row CT (MDCT) abdominal CT angiography (CTA). In addition, we aimed to study the feasibility of using HCCM with a reduced total iodine dose. Methods CTA of the abdomen on a 64-slice MDCT was performed on 15 anaesthetised pigs. Study pigs were divided into three groups of five each based on the iodine concentration and dose received: Group A (LCCM; 300 mg I ml–1), Group B (HCCM; 370 mg I ml–1) and Group C HCCM with 20% less iodine dose. The total iodine injected was kept constant (600 mg kg–1) in Groups A and B. Qualitative and quantitative analyses were performed to study and compare each group for image quality, visibility of the branch order of the superior mesenteric artery (SMA), artefacts, degree of enhancement in the aorta and main stem arteries and uniformity of enhancement in the aorta. Groups were compared using the analysis of variance test. Results The image quality of 64-slice MDCT angiography was excellent with a mean score of 4.63 and confident visualisation of the third to fifth order branches of the SMA in all groups. Group B demonstrated superior vascular enhancement, as compared with Groups A and C (p≤0.05). Uniform aortic enhancement was achieved with the use of LCCM and HCCM with 20% less iodine dose. Conclusion 64-slice MDCT angiography of the abdomen was of excellent quality. HCCM improves contrast enhancement and overall CTA image quality and allows the iodine dose to be reduced. PMID:21081582

  5. Detection of the anatomic structure and pathology in animal lung specimens: comparison of micro CT and multi-detector row CT

    International Nuclear Information System (INIS)

    Lim, Kun Young; Lee, Hyun Ju; Lee, Chang Hyun; Son, Kyu Ri; Goo, Jin Mo; Im, Jung Gi; Seo, Joon Beom

    2006-01-01

    We wanted to compare the capability of micro CT and the clinically available thin-slice multi-detector row CT (MDCT) for demonstrating fine anatomic structures and pathological lesions in formalin-fixed lung specimens. The porcine lung with shark liver oil-induced lipoid pneumonia and the canine lung with pulmonary paragonimiasis were fixed by ventilating them with formalin vapor, and they were then sliced into one-centimeter thick sections. Micro CT (section thickness, 18 micrometer) and MDCT (section thickness, 0.75 mm) images were acquired in four of the lung slices of the lipoid pneumonia specimen and in five of the lung slices of the paragonimiasis specimen. On 62 pairs of micro CT and MDCT images, 169 pairs of rectangular ROIs were manually drawn in the corresponding locations. Two chest radiologists recorded the detectability of three kinds of anatomic structures (lobular core structure, interlobular septum and small bronchiolar lumen) and two kinds of pathological lesions (ground-glass opacity and consolidation) with using a five-point scale. The statistical comparison was performed by using the Wilcoxon signed rank test. Interobserver agreement was evaluated with kappa statistics. For all observers, all the kinds of anatomic structures and pathological lesions were detected better on the micro CT images than on the MDCT images (ρ < 0.01). Agreement was fair between two observers (κ = 0.38, ρ < 0.001). The fine anatomic structures and pathological lesions of the lung were more accurately demonstrated on micro CT than on thin-slice MDCT in the inflated and fixed lung specimens

  6. Comparison radiation dose of Z-axis automatic tube current modulation technique with fixed tube current multi-detector row CT scanning of lower extremity venography

    International Nuclear Information System (INIS)

    Yoo, Beong Gyu; Kweon, Dae Cheol; Lee, Jong Seok; Jang, Keun Jo; Jeon, Sang Hwan; Kim, Yong Soo

    2007-01-01

    Z-axis automatic tube current modulation technique automatically adjusts tube current based on size of body region scanned. The purpose of the current study was to compare noise, and radiation dose of Multi-Detector row CT (MDCT) of lower extremity performed with Z-axis modulation technique of automatic tube current modulation with manual selection fixed tube current. Fifty consecutive underwent MDCT venography of lower extremity with use of a MDCT scanner fixed tube current and Z-axis automatic tube current modulation technique (10, 11 and 12 HU noise index, 70∼450 mA). Scanning parameters included 120 kVp, 0.5 second gantry rotation time, 1.35:1 beam pitch, and 1 mm reconstructed section thickness. For each subject, images obtained with Z-axis modulation were compared with previous images obtained with fixed tube current (200, 250, 300 mA) and with other parameters identical. Images were compared for noise at five levels: iliac, femoral, popliteal, tibial, and peroneal vein of lower extremity. Tube current and gantry rotation time used for acquisitions at these levels were recorded. All CT examinations of study and control groups were diagnostically acceptable, though objective noise was significantly more with Z-axis automatic tube current modulation. Compared with fixed tube current, Z-axis modulation resulted in reduction of CTDIvol (range, -6.5%∼-35.6%) and DLP (range,-0.2%∼-20.2%). Compared with manually selected fixed tube current, Z-axis automatic tube current modulation resulted in reduced radiation dose at MDCT of lower extremity venography

  7. Multi-detector row CT of the head and neck: comparison of different volumes of contrast material with and without a saline chaser

    International Nuclear Information System (INIS)

    Yoon, Dae Young; You, Su Yeon; Choi, Chul Soon; Chang, Suk Ki; Yun, Eun Joo; Seo, Young Lan; Park, Sang Joon; Lee, Yu-Jin; Moon, Jeung Hee; Rho, Young-Soo; Kim, Jin-Hwan

    2006-01-01

    The aim of this study was to determine the effect of different volumes of contrast material with and without a saline chaser on tissue enhancement in multidetector row CT (MDCT) of the head and neck. In a blind prospective fashion, 120 patients were randomized into the following four groups: group 1, 80 ml contrast material administered at a flow rate of 2.0 ml/s; group 2, 80 ml followed by 40 ml saline at 2.0 ml/s; group 3, 60 ml at 1.5 ml/s; and group 4, 60 ml followed by 30 ml saline at 1.5 ml/s. The attenuation values of the carotid artery, internal jugular vein, and muscle were measured at an interval of 1.5 s in each patient. The degree of perivenous artifacts was subjectively assessed. Mean attenuation values in the carotid artery and internal jugular vein were significantly higher in groups 1 and 2 than in groups 3 and 4. The width of the diagnostic window (both carotid and jugular enhancement >150 HU) were significantly longer in groups 1 and 2 than in groups 3 and 4. The addition of a saline chaser did not result in improved vascular enhancement or a wider diagnostic window, but reduced perivenous artifacts, compared with using contrast material alone. Reduction of contrast material from 80 to 60 ml results in insufficient enhancement of neck vessels. In addition, the benefit of a saline chaser technique is not obvious except for its ability to reduce perivenous artifacts. (orig.)

  8. Depiction of variants of the portal confluence venous system using multidetector row CT. Analysis of 916 cases

    Energy Technology Data Exchange (ETDEWEB)

    Krumm, P.; Schraml, C.; Bretschneider, C.; Seeger, A.; Klumpp, B.; Kramer, U.; Claussen, C.D.; Miller, S. [Universitaetsklinikum Tuebingen (Germany). Abt. fuer Diagnostische und Interventionelle Radiologie

    2011-12-15

    Purpose: Detailed knowledge of the venous mesenteric system is important for gastrointestinal surgery, particularly for transplantation planning and surgery and for the comprehension of perioperative complications that may influence patient outcome. Data about the mesenteric venous anatomy in the literature varies substantially. The purpose of this study was to categorize venous mesenteric variants and to determine their incidence. Materials and Methods: We included 916 patients requiring diagnostic abdominal CT in the portal venous phase. The mesenteric vein anatomy was categorized as follows: 1. the inferior mesenteric vein (IMV) enters the splenic vein (SV); 2. the IMV enters into the angle of the confluence of the SV and superior mesenteric vein (SMV) forming the portal vein (PV); 3. the IMV enters the SMV; 4. seven rare variants. We measured the diameters of the veins and distances from the confluence to the IMV origins. Results: The frequency of variants was: 1. 37.6 %, 2. 28.8 %; 3. 19.2 %. The rare variants totaled 14.4 %. The average vessel diameters measured in cm: PV 1.48; SV 1.02; SMV 1.2; IMV 0.5. The mean IMV entering distances were 1.66 cm in variant 1 and 0.75 cm in variant 3. Conclusion: The three common variants (1, 2 and 3) are the most relevant ones. 14.4 % of patients had different anatomic variants. The variability of the mesenteric venous system was higher than previously published. Knowledge of rare variants is important to avoid complications in abdominal surgery. (orig.)

  9. Depiction of variants of the portal confluence venous system using multidetector row CT. Analysis of 916 cases

    International Nuclear Information System (INIS)

    Krumm, P.; Schraml, C.; Bretschneider, C.; Seeger, A.; Klumpp, B.; Kramer, U.; Claussen, C.D.; Miller, S.

    2011-01-01

    Purpose: Detailed knowledge of the venous mesenteric system is important for gastrointestinal surgery, particularly for transplantation planning and surgery and for the comprehension of perioperative complications that may influence patient outcome. Data about the mesenteric venous anatomy in the literature varies substantially. The purpose of this study was to categorize venous mesenteric variants and to determine their incidence. Materials and Methods: We included 916 patients requiring diagnostic abdominal CT in the portal venous phase. The mesenteric vein anatomy was categorized as follows: 1. the inferior mesenteric vein (IMV) enters the splenic vein (SV); 2. the IMV enters into the angle of the confluence of the SV and superior mesenteric vein (SMV) forming the portal vein (PV); 3. the IMV enters the SMV; 4. seven rare variants. We measured the diameters of the veins and distances from the confluence to the IMV origins. Results: The frequency of variants was: 1. 37.6 %, 2. 28.8 %; 3. 19.2 %. The rare variants totaled 14.4 %. The average vessel diameters measured in cm: PV 1.48; SV 1.02; SMV 1.2; IMV 0.5. The mean IMV entering distances were 1.66 cm in variant 1 and 0.75 cm in variant 3. Conclusion: The three common variants (1, 2 and 3) are the most relevant ones. 14.4 % of patients had different anatomic variants. The variability of the mesenteric venous system was higher than previously published. Knowledge of rare variants is important to avoid complications in abdominal surgery. (orig.)

  10. Evaluation of Deep Vein Thrombosis with Multidetector Row CT after Orthopedic Arthroplasty: a Prospective Study for Comparison with Doppler Sonography

    International Nuclear Information System (INIS)

    Byun, Sung Su; Kim, Youn Jeong; Chun, Yong Sun; Kim, Won Hong; Kim, Jeong Ho; Park, Chul Hi

    2008-01-01

    This prospective study evaluated the ability of indirect 16-row multidetector CT venography, in comparison with Doppler sonography, to detect deep vein thrombosis after total hip or knee replacement. Sixty-two patients had undergone orthopedic replacement surgery on a total of 30 hip joints and 54 knee joints. The CT venography (scan delay time: 180 seconds; slice thickness/increment: 2/1.5 mm) and Doppler sonography were performed 8 to 40 days after surgery. We measured the z-axis length of the beam hardening artifact that degraded the image quality so that the presence of deep vein thrombosis couldn't be evaluated on the axial CT images. The incidence and location of deep vein thrombosis was analyzed. The diagnostic performance of the CT venograms was evaluated and compared with that of Doppler sonography as a standard of reference. The z-axis length (mean±standard deviation) of the beam hardening artifact was 4.5±0.8 cm in the arthroplastic knees and 3.9±2.9 cm in the arthroplastic hips. Deep vein thrombosis (DVT) was found in the popliteal or calf veins on Doppler sonography in 30 (48%) of the 62 patients. The CT venography has a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 90%, 97%, 96%, 91% and 94%, respectively. The ability of CT venography to detect DVT was comparable to that of Doppler sonography despite of beam hardening artifact. Therefore, CT venography is feasible to use as an alternative modality for evaluating postarthroplasty patients

  11. Evaluation of Deep Vein Thrombosis with Multidetector Row CT after Orthopedic Arthroplasty: a Prospective Study for Comparison with Doppler Sonography

    Energy Technology Data Exchange (ETDEWEB)

    Byun, Sung Su; Kim, Youn Jeong; Chun, Yong Sun; Kim, Won Hong [Inha University, College of Medicine, Incheon (Korea, Republic of); Kim, Jeong Ho; Park, Chul Hi [Gachon University, Gil Medical Center, Incheon (Korea, Republic of)

    2008-02-15

    This prospective study evaluated the ability of indirect 16-row multidetector CT venography, in comparison with Doppler sonography, to detect deep vein thrombosis after total hip or knee replacement. Sixty-two patients had undergone orthopedic replacement surgery on a total of 30 hip joints and 54 knee joints. The CT venography (scan delay time: 180 seconds; slice thickness/increment: 2/1.5 mm) and Doppler sonography were performed 8 to 40 days after surgery. We measured the z-axis length of the beam hardening artifact that degraded the image quality so that the presence of deep vein thrombosis couldn't be evaluated on the axial CT images. The incidence and location of deep vein thrombosis was analyzed. The diagnostic performance of the CT venograms was evaluated and compared with that of Doppler sonography as a standard of reference. The z-axis length (mean{+-}standard deviation) of the beam hardening artifact was 4.5{+-}0.8 cm in the arthroplastic knees and 3.9{+-}2.9 cm in the arthroplastic hips. Deep vein thrombosis (DVT) was found in the popliteal or calf veins on Doppler sonography in 30 (48%) of the 62 patients. The CT venography has a sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 90%, 97%, 96%, 91% and 94%, respectively. The ability of CT venography to detect DVT was comparable to that of Doppler sonography despite of beam hardening artifact. Therefore, CT venography is feasible to use as an alternative modality for evaluating postarthroplasty patients.

  12. Coronary artery anomalies: Assessment with electrocardiography-gate multidetector-row CT at a single center in Korea

    International Nuclear Information System (INIS)

    Yi, Bo Ram; Sun, Joo Sung; Yang, Hyoung Mo; Kang, Doo Kyoung

    2015-01-01

    To determine the prevalence of coronary anomalies using coronary computed tomography angiography (CCTA) and to evaluate the relationship between coronary artery anomalies and chest pain. A total of 12676 patients underwent CCTA scans at our institution between December 2006 and April 2013 using a 64-slice CT and a 128-slice dual-source CT. We determined the prevalence of coronary artery anomalies according to the classification system proposed by Greenberg. The presence or absence of chest pain with each coronary artery anomaly was also evaluated. Coronary anomalies were found in 176 patients (1.39%) at our institute. Anomalies of origination, course, and termination were detected in 118 (0.93%), 28 (0.22%), and 30 (0.24%) patients, respectively. After the exclusion of 32 patients with combined heart disease, typical (n = 16; 11.1%) or atypical (n = 28; 19.4%) chest pain was present in 44 (30.6%) of the 144 patients at the time of diagnosis. The prevalence of coronary artery anomalies was 1.39% at our hospital. After the exclusion of patients with combined heart disease, 11.1% had typical chest pain at the time of diagnosis.

  13. Diagnostic assessment of painless microhematuria: prospective study comparing image quality, assessibility and diagnostic certainty of multidetector-row CT and intravenous pyelography within a single examination

    International Nuclear Information System (INIS)

    Boehm, T.; John, H.; Ruedi, C.; Marincek, B.; Wildermuth, S.; Michael, M.

    2005-01-01

    Purpose: The purpose of this study is to prospectively compare intravenous pyelography (IVP) and combined unenhanced and excretory phase multidetector-row CT (MDCT) with respect to image quality, diagnostic certainty and diagnostic concordance with the final clinical diagnosis in patients with painless microhematuria. Materials and Methods: Unenhanced MDCT, IVP and excretory phase MDCT were performed in 59 consecutive patients (21 women, 38 men, mean age 56±19 years, range 23-83 years) with painless microhematuria of unknown origin during a single examination with a single contrast media application (100 ml, non-ionic iodinate contrast media). Images were assessed by two experienced urogenital radiologists in consensus for image quality, diagnostic certainty of stone detection, obstruction, parenchymal lesions and morphological distinctive features. Imaging diagnoses of MDCT and IVP were compared with the final clinical diagnoses. In case of failure to detect an relevant pathology, the final clinical diagnosis was established after a mean follow-up period of 18±6 months (10 months to 2 years). Costs and radiation exposure of IVP and MDCT were compared. Results: MDCT scan performed better than IVP in terms of image quality for all regarded variables. Image quality of MDCT was rated in all parameters as very good or good; the image quality of IVP differed in a wide range. MDCT and IVP reached a sensitivity of 100% and 50% for stone detection (n=14, p=0.008), respectively. Two bladder stones were not detected by IVU but correctly seen with MDCT. MDCT and IVP were unsatisfactory for detecting transitional cell carcinomas (n=4, 2 of 4 detected with MDCT, 0 of 4 detected with IVU). One false positive transitional cell carcinoma was detected with IVP, none with MDCT. Additional relevant pathological changes (one teratoma, one abdominal aortic aneurysma and one abscess) were detected using MDCT but missed with IVP. In 38 of 59 patients (64%) imaging and clinical follow

  14. Detection of intestinal bleeding with multi-detector row CT in an experimental setup. How many acquisitions are necessary?

    International Nuclear Information System (INIS)

    Dobritz, Martin; Engels, Heinz-Peter; Bauer, Jan; Rummeny, Ernst J.; Schneider, Armin

    2009-01-01

    The purpose of the study was to evaluate multi-detector computed tomography (MDCT) acquired in different acquisitions (unenhanced, and arterial and portal venous phase following intravenous contrast medium) for detection of intestinal bleeding using an experimental bowel model. The model consisted of an injector tube with a perforation placed in a 7-m-long small bowel of a pig. The bowel was filled with water/contrast medium solution of 30-40 HU and was incorporated in a phantom model. Intestinal bleeding in different locations and bleeding velocities varying from zero to 0.75 ml/min (0.05 ml/min increments) were simulated. Twenty-six datasets in simulated unenhanced, arterial and portal venous contrast phase using increasing bleeding velocities and ten negative controls were measured using 64-row MDCT. Two radiologists blinded to the experimental settings evaluated the datasets in a random order. The likelihood of intestinal bleeding was assessed using a 5-point scale with subsequent ROC analysis. The overall sensitivity for detecting bleeding was 0.44 for an arterial acquisition alone, 0.68 for a portal venous acquisition, 0.68 for the combination unenhanced/arterial, 0.72 for unenhanced/portal venous and 0.80 for arterial/portal. Bleeding velocities of above 0.25 ml/min were detected with a sensitivity of 0.59 for arterial, 0.88 for portal venous, 0.85 for unenhanced/arterial, 0.94 for unenhanced/portal venous and 0.97 for arterial/portal venous contrast phase protocols, respectively. The specificity was 1.00. MDCT provides the highest sensitivity and specificity in the detection of intestinal bleeding using arterial and portal venous acquisition in comparison to mono-phase protocols. (orig.)

  15. Impaired left ventricular function has a detrimental effect on image quality in multi-detector row CT coronary angiography

    International Nuclear Information System (INIS)

    Manghat, N.E.; Morgan-Hughes, G.J.; Shaw, S.R.; Marshall, A.J.; Roobottom, C.A.

    2008-01-01

    Aim: To determine whether there is a relationship between left ventricular (LV) haemodynamic parameters, circulation times, and arterial contrast opacification that might affect the image quality of computed tomography (CT) coronary angiography. Methods: Thirty-six patients were included in the study: 18 with cardiomyopathy (CM) and LV dilatation of suspected ischaemic aetiology [age 57.9 ± 13.7 years, range 30-77 years; 14 male, four female; body mass index (BMI) = 27.7 ± 4.5, range 25.5-31.8] and 18 controls (age 62.3 ± 9.4 years, range 47-89 years; 10 male, eight female; BMI 27.8 ± 6.6; range 19.2-33.6). Coronary artery image quality was assessed using a three-point visual scale; contrast medium circulation times, aortic root contrast attenuation, and LV functional parameters were studied. Results: Visually reduced contrast opacification impaired image quality more often in the CM group than the control group (27.4 versus 5.1%). A total of 55.6% CM patients had a contrast transit time ranging from 30-75 s; the number of 'unassessable' segments increased with increasing transit time conforming to a fitted quadratic model (R 2 = 0.74). The relationship between LV ejection fraction and contrast attenuation may also conform to a quadratic model (R 2 = 0.71). Conclusion: LV haemodynamics influence coronary artery opacification using cardiac CT, and users imaging this subgroup must do so with the knowledge of this potential pitfall. The results indicate the need for further studies examining CT protocols in this clinical subgroup

  16. [Comparison of radiation dose reduction of prospective ECG-gated one beat scan using 320 area detector CT coronary angiography and prospective ECG-gated helical scan with high helical pitch (FlashScan) using 64 multidetector-row CT coronary angiography].

    Science.gov (United States)

    Matsutani, Hideyuki; Sano, Tomonari; Kondo, Takeshi; Fujimoto, Shinichiro; Sekine, Takako; Arai, Takehiro; Morita, Hitomi; Takase, Shinichi

    2010-12-20

    A high radiation dose associated with 64 multidetector-row computed tomography (64-MDCT) is a major concern for physicians and patients alike. A new 320 row area detector computed tomography (ADCT) can obtain a view of the entire heart with one rotation (0.35 s) without requiring the helical method. As such, ADCT is expected to reduce the radiation dose. We studied image quality and radiation dose of ADCT compared to that of 64-MDCT in patients with a low heart rate (HR≤60). Three hundred eighty-five consecutive patients underwent 64-MDCT and 379 patients, ADCT. Patients with an arrhythmia were excluded. Prospective ECG-gated helical scan with high HP (FlashScan) in 64 was used for MDCT and prospective ECG-gated conventional one beat scan, for 320-ADCT. Image quality was visually evaluated by an image quality score. Radiation dose was estimated by DLP (mGy・cm) for 64-MDCT and DLP.e (mGy・cm) for 320-ADCT. Radiation dose of 320-ADCT (208±48 mGy・cm) was significantly (P<0.0001) lower than that of 64-MDCT (484±112 mGy・cm), and image quality score of 320-ADCT (3.0±0.2) was significantly (P=0.0011) higher than that of 64-MDCT (2.9±0.4). Scan time of 320-ADCT (1.4±0.1 s) was also significantly (P<0.0001) shorter than that of 64-MDCT (6.8±0.6 s). 320-ADCT can achieve not only a reduction in radiation dose but also a superior image quality and shortening of scan time compared to 64-MDCT.

  17. Computational Modeling in Liver Surgery

    Directory of Open Access Journals (Sweden)

    Bruno Christ

    2017-11-01

    Full Text Available The need for extended liver resection is increasing due to the growing incidence of liver tumors in aging societies. Individualized surgical planning is the key for identifying the optimal resection strategy and to minimize the risk of postoperative liver failure and tumor recurrence. Current computational tools provide virtual planning of liver resection by taking into account the spatial relationship between the tumor and the hepatic vascular trees, as well as the size of the future liver remnant. However, size and function of the liver are not necessarily equivalent. Hence, determining the future liver volume might misestimate the future liver function, especially in cases of hepatic comorbidities such as hepatic steatosis. A systems medicine approach could be applied, including biological, medical, and surgical aspects, by integrating all available anatomical and functional information of the individual patient. Such an approach holds promise for better prediction of postoperative liver function and hence improved risk assessment. This review provides an overview of mathematical models related to the liver and its function and explores their potential relevance for computational liver surgery. We first summarize key facts of hepatic anatomy, physiology, and pathology relevant for hepatic surgery, followed by a description of the computational tools currently used in liver surgical planning. Then we present selected state-of-the-art computational liver models potentially useful to support liver surgery. Finally, we discuss the main challenges that will need to be addressed when developing advanced computational planning tools in the context of liver surgery.

  18. Non-invasive detection of aortic and coronary atherosclerosis in homozygous familial hypercholesterolemia by 64 slice multi-detector row computed tomography angiography

    Science.gov (United States)

    Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis, often at the ostia of coronary arteries. In this study we document for the first time that aortic and coronary atherosclerosis can be detected using 64 slice multiple detector row ...

  19. Evaluation to Obtain the Image According to the Spatial Domain Filtering of Various Convolution Kernels in the Multi-Detector Row Computed Tomography

    International Nuclear Information System (INIS)

    Lee, Hoo Min; Yoo, Beong Gyu; Kweon, Dae Cheol

    2008-01-01

    Our objective was to evaluate the image of spatial domain filtering as an alternative to additional image reconstruction using different kernels in MDCT. Derived from thin collimated source images were generated using water phantom and abdomen B10(very smooth), B20(smooth), B30(medium smooth), B40 (medium), B50(medium sharp), B60(sharp), B70(very sharp) and B80(ultra sharp) kernels. MTF and spatial resolution measured with various convolution kernels. Quantitative CT attenuation coefficient and noise measurements provided comparable HU(Hounsfield) units in this respect. CT attenuation coefficient(mean HU) values in the water were values in the water were 1.1∼1.8 HU, air(-998∼-1000 HU) and noise in the water(5.4∼44.8 HU), air(3.6∼31.4 HU). In the abdominal fat a CT attenuation coefficient(-2.2∼0.8 HU) and noise(10.1∼82.4 HU) was measured. In the abdominal was CT attenuation coefficient(53.3∼54.3 HU) and noise(10.4∼70.7 HU) in the muscle and in the liver parenchyma of CT attenuation coefficient(60.4∼62.2 HU) and noise (7.6∼63.8 HU) in the liver parenchyma. Image reconstructed with a convolution kernel led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image scanned with a high convolution kernel(B80) led to an increase in noise, whereas the results for CT attenuation coefficient were comparable. Image medications of image sharpness and noise eliminate the need for reconstruction using different kernels in the future. Adjusting CT various kernels, which should be adjusted to take into account the kernels of the CT undergoing the examination, may control CT images increase the diagnostic accuracy.

  20. Video-assisted breast surgery and 3-dimensional computed tomographic mammary lymphography (2). Sentinel node biopsy with 3D-CT mammary lymphography

    International Nuclear Information System (INIS)

    Yamashita, Koji

    2010-01-01

    I have studied endoscopic surgery for breast diseases and 3-dimensional (3D) computed tomographic (CT) lymphography for sentinel node (SN) biopsy. In this second in a series of reports, I explain the techniques of 3D-CT lymphography. 3D-CT lymphography can show the detailed lymphatic flow from the breast tumor toward the SNs and the exact local relation between axillary lymph nodes. I have developed this 3D image-processing system to more precisely depict the anatomical structures of the mammary lymphovascular system. This system allows us to systematically collect axillary lymph nodes, including SNs. 3D-CT lymphography was performed to mark SNs on the skin on the day before surgery. Above the tumor and near the areola, 2 ml of Iopamiron 300 was injected subcutaneously. Sixteen-channel multidetector-row helical CT scan images were obtained 1 minute after injection to detect SNs, and after 3 and 5 minutes to observe lymph flow into the venous angle. The scan images were reconstructed to produce 3D images. SN biopsy was performed with the dye-staining method and endoscopy. 3D-CT lymphography accurately showed lymphatic flow from the tumor to SNs. We classified the relationship between the lymph ducts and the drained SNs into 4 patterns. Following up 3 and 5 minutes after injection of the contrast agent, we can follow the lymph ducts beyond the SN into the second and third nodes toward the venous angle with the complex plexus. The figure of the axillary nodes shows 5 beads-like grouped nodes. 3D-CT lymphography can also recognize the metastatic patterns of the enhanced lymph node. These patterns will predict the metastasis before SN biopsy. 3D-CT lymphography can also be used to detect lymph flow from the arm to avoid harming the arm lymph channel during axillary node dissection and SN biopsy. With 3D-CT lymphography, we can more accurately and precisely recognize lymph flow and the positional relations of SN and axillary nodes to surrounding anatomical structures

  1. Usefulness of multidetector-row CT (MDCT) for the diagnosis of non-occlusive mesenteric ischemia (NOMI): Assessment of morphology and diameter of the superior mesenteric artery (SMA) on multi-planar reconstructed (MPR) images

    International Nuclear Information System (INIS)

    Woodhams, Reiko; Nishimaki, Hiroshi; Fujii, Kaoru; Kakita, Satoko; Hayakawa, Kazushige

    2010-01-01

    Objective: The purpose of this study was to assess the efficacy of multidetector-row CT (MDCT) for the diagnosis of non-occlusive mesenteric ischemia (NOMI) by analyzing morphology and diameter of superior mesenteric artery (SMA). We assessed whether MDCT was as useful as angiography for the diagnosis of NOMI. Materials and methods: Four patients who were diagnosed with NOMI were retrospectively analyzed. All patients had 8-row MDCT followed by laparotomy. Two of them underwent angiography after MDCT. The morphology and diameter of SMA of these cases was analyzed on multi-planar reconstructed (MPR) images. The mean diameter of SMA of NOMI cases was compared to that of 13 control cases. Results: MPR images of all NOMI cases showed irregular narrowing of the SMA, spasm of the arcades of SMA, and poor demonstration of intramural vessels. MPR images of two patients who had angiography were concordant with their angiograms. The mean diameter of SMA of NOMI patients was 3.4 ± 1.1 mm, which was statistically smaller than that of 13 control patients, 6.0 ± 1.5 mm (P < 0.05, Wilcoxon rank sum tests). Conclusion: Angiography has been recognized essential for the diagnosis of NOMI. This study shows the possibility of MDCT to be an equivalently useful modality compared to angiography for the diagnosis of NOMI by interpreting morphologic appearance and diameter of SMA. Introduction of MDCT in the decision tree of NOMI treatment may bring the benefit of prompt diagnosis and subsequent early and efficient initiation of therapy, which may improve the mortality.

  2. The Incidence and Anatomy of Accessory Pudendal Arteries as Depicted on Multidetector-Row CT Angiography: Clinical Implications of Preoperative Evaluation for Laparoscopic and Robot-Assisted Radical Prostatectomy

    International Nuclear Information System (INIS)

    Park, Beom Jin; Sung, Deuk Jae; Kim, Min Ju; Cho, Sung Bum; Kim, Yun Hwan; Chung, Kyoo Byung; Kang, Seok Ho; Cheon, Jun

    2009-01-01

    To help preserve accessory pudendal arteries (APAs) and to ensure optimal postoperative sexual function after a laparoscopic or robot-assisted radical prostatectomy, we have evaluated the incidence of APAs as detected on multidetector-row CT (MDCT) angiography and have provided a detailed anatomical description. The distribution of APAs was evaluated in 121 consecutive male patients between February 2006 and July 2007 who underwent 64- channel MDCT angiography of the lower extremities. We defined an APA as any artery located within the periprostatic region running parallel to the dorsal vascular complex. We also subclassified APAs into lateral and apical APAs. Two radiologists retrospectively evaluated the origin, course and number of APAs; the final APA subclassification based on MDCT angiography source data was determined by consensus. We identified 44 APAs in 36 of 121 patients (30%). Two distinct varieties of APAs were identified. Thirty-three APAs (75%) coursed near the anterolateral region of the prostatic apex, termed apical APAs. The remaining 11 APAs (25%) coursed along the lateral aspect of the prostate, termed lateral APAs. All APAs originated from the internal obturator artery and iliac artery or a branch of the iliac artery such as the inferior vesical artery. The majority of apical APAs arose from the internal obturator artery (84%). Seven patients (19%) had multiple APAs. APAs are more frequently detected by the use of MDCT angiography than as suggested by previous surgical studies. The identification of APAs on MDCT angiography may provide useful information for the surgical preservation of APAs during a laparoscopic or robot-assisted radical prostatectomy

  3. Information technology in the strategy of digestive surgery. (2) Advances of CAD system using OsiriX

    International Nuclear Information System (INIS)

    Sugimoto, Maki; Yasuda, Hideki; Koda, Keiji; Yamazaki, Masato; Tezuka, Tohru; Kosugi, Chihiro; Watayo, Yoshihisa; Naka, Shuji

    2007-01-01

    OsiriX, one of information technology (IT) product in medicine, is an image processing system developed by surgeons and its software for Mac OS can be installed free of charge (http://homepage.mac.com/rossetantoine/osrix/). The present review describes the practical application of this computer-aided diagnostic (CAD) tool mainly in the field of surgery of hepato-biliary-pancreatic system. Authors are successfully utilizing the OsiriX for pre-operative diagnosis by modalities of multidetector-row CT (MDCT), MRI and PET images, for simulation of surgery by volume rendering, carbon dioxide MDCT cholangiopancreatography (CMCP), 3D vascular construction MDCT angiography and virtual reality, and for navigation during the actual operation. The machine they use is 16-row MDCT LightSpeed Ultra 16 (GE Healthcare), and their data are processed through the Digital Imaging and Communications in Medicine (DICOM) viewer OsiriX 2.6, Power Mac G5, MacBook Pro (Apple Computer, Inc.) and 3D image processing engine (TeraRecon, Inc.). Presented are details of decision of region of interest (ROI), 3D ROI extraction by region-growing, MacBook Pro and iPod, and IT surgery by OsiriX, which are still being improved day by day. (T.I.)

  4. Computer assisted radiology and surgery. CARS 2010

    International Nuclear Information System (INIS)

    Anon.

    2010-01-01

    The conference proceedings include contributions to the following topics: (1) CARS Clinical Day: minimally invasive spiral surgery, interventional radiology; (2) CARS - computer assisted radiology and surgery: ophthalmology, stimulation methods, new approaches to diagnosis and therapy; (3) Computer assisted radiology 24th International congress and exhibition: computer tomography and magnetic resonance, digital angiographic imaging, digital radiography, ultrasound, computer assisted radiation therapy, medical workstations, image processing and display; (4) 14th Annual conference of the International Society for computer aided surgery; ENT-CMF head and neck surgery computer-assisted neurosurgery, cardiovascular surgery, image guided liver surgery, abdominal and laparoscopic surgery, computer-assisted orthopedic surgery, image processing and visualization, surgical robotics and instrumentation, surgical modeling, simulation and education; (5) 28th International EuroPACS meeting: image distribution and integration strategies, planning and evaluation, telemedicine and standards, workflow and data flow in radiology; (6) 11th CARS/SPIE/EuroPACS joint workshop on surgical PACS and the digital operating, management and assessment of OR systems and integration; (7) 12th International workshop on computer-aided diagnosis: special session on breast CAD, special session on thoracic CAD, special session on abdominal brain, lumbar spine CAD; (8) 16th computed Maxillofacial imaging congress: computed maxillofacial imaging in dental implantology, orthodontics and dentofacial orthopedics; approaches to 3D maxillofacial imaging; surgical navigation; (9) 2nd EuroNOTES/CARS workshop on NOTES: an interdisciplinary challenge; (10) 2nd EPMA/CARS workshop on personalized medicine and ICT.; (11)poster sessions.

  5. Computer assisted radiology and surgery. CARS 2010

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-06-15

    The conference proceedings include contributions to the following topics: (1) CARS Clinical Day: minimally invasive spiral surgery, interventional radiology; (2) CARS - computer assisted radiology and surgery: ophthalmology, stimulation methods, new approaches to diagnosis and therapy; (3) Computer assisted radiology 24th International congress and exhibition: computer tomography and magnetic resonance, digital angiographic imaging, digital radiography, ultrasound, computer assisted radiation therapy, medical workstations, image processing and display; (4) 14th Annual conference of the International Society for computer aided surgery; ENT-CMF head and neck surgery computer-assisted neurosurgery, cardiovascular surgery, image guided liver surgery, abdominal and laparoscopic surgery, computer-assisted orthopedic surgery, image processing and visualization, surgical robotics and instrumentation, surgical modeling, simulation and education; (5) 28th International EuroPACS meeting: image distribution and integration strategies, planning and evaluation, telemedicine and standards, workflow and data flow in radiology; (6) 11th CARS/SPIE/EuroPACS joint workshop on surgical PACS and the digital operating, management and assessment of OR systems and integration; (7) 12th International workshop on computer-aided diagnosis: special session on breast CAD, special session on thoracic CAD, special session on abdominal brain, lumbar spine CAD; (8) 16th computed Maxillofacial imaging congress: computed maxillofacial imaging in dental implantology, orthodontics and dentofacial orthopedics; approaches to 3D maxillofacial imaging; surgical navigation; (9) 2nd EuroNOTES/CARS workshop on NOTES: an interdisciplinary challenge; (10) 2nd EPMA/CARS workshop on personalized medicine and ICT.; (11)poster sessions.

  6. Intravenous contrast medium administration at 128 multidetector row CT pulmonary angiography: Bolus tracking versus test bolus and the implications for diagnostic quality and effective dose

    International Nuclear Information System (INIS)

    Rodrigues, J.C.L.; Mathias, H.; Negus, I.S.; Manghat, N.E.; Hamilton, M.C.K.

    2012-01-01

    Aim: To investigate the effects of a test bolus protocol contrast medium administration on diagnostic image quality in computed tomography pulmonary angiography (CTPA). Materials and methods: Fifty patients referred for exclusion of pulmonary embolism underwent CTPA using a test bolus protocol CTPA at 120 kVp and were compared with 50 patients undergoing CTPA using a standard bolus-tracking protocol at 120 kVp, via assessment of attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) seen in the pulmonary arteries (PAs). An additional group of 10 non-obese patients who underwent CTPA using a test bolus protocol performed at 100 kVp were also analysed. Mean effective dose was calculated from the dose–length product, using standard conversion factors. Results: The test bolus protocol showed significantly higher attenuation, SNR, and CNR in the pulmonary vasculature down to the segmental level compared to bolus-tracking CTPA (p < 0.0001). There was no significant difference in effective dose between the test bolus and bolus tracking cohorts. The additional group of test bolus CTPA examinations performed at 100 kVp had a significantly reduced effective dose in comparison to both test bolus CTPA at 120 kVp and bolus-tracking CTPA at 120 kVp (p < 0.005) yet maintained mean PA attenuation to segmental level significantly better than bolus-tracking CTPA performed at 120 kVp and comparable to the test bolus cohort performed at 120 kVp. Conclusion: Test bolus contrast administration should be used as an optimal protocol. Performing test bolus CTPA at 100 kVp, as opposed to 120 kVp, significantly reduces dose without compromising PA attenuation in non-obese subjects.

  7. Computed tomography, after abdominal surgery

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, H.; Toedt, H.C.

    1985-09-01

    The CT-examinations of 131 patients were analyzed after abdominal surgery. After nephrectomy, splenectomy, partial hepatectomy and pancreatectomy a displacement of the neighbouring intraabdominal and retroperitoneal organs was seen. Scar-tissue was observed containing fat, which faciltated the differential diagnosis to tumor recurrency. The changes of the roentgenmorphology were not so obvious after gastrointestinal surgery. After vascular surgery the permeability of an anastomosis or an operated artery could be demonstrated by bolus injection. (orig.).

  8. Computed tomography, after abdominal surgery

    International Nuclear Information System (INIS)

    Vogel, H.; Toedt, H.C.; Hamburg Univ.

    1985-01-01

    The CT-examinations of 131 patients were analyzed after abdominal surgery. After nephrectomy, splenectomy, partial hepatectomy and pancreatectomy a displacement of the neighbouring intraabdominal and retroperitoneal organs was seen. Scar-tissue was observed containing fat, which fascilated the differentialdiagnosis to tumorrecurrency. The changes of the roentgenmorphology were not so abvious after gastro-intestinal surgery. After vascular surgery the permeability of an anastomosis or an operated artery could be demonstrated by bolusinjection. (orig.) [de

  9. Pitfalls in multidetector row CT colonography

    International Nuclear Information System (INIS)

    Stoyneva, V.

    2009-01-01

    Full text:MDCT colonography is a reliable method for detection and identification of type of the colon lesions. At every step of the examination an error could be made and that would be lead to an incorrect diagnosis. Problems and pitfalls can be overcome with various useful techniques. The relatively clean and dry colon after careful preparation, allows avoiding problems of residual fluid and faeces. The knowledge about the structure and thickness characteristics of lesions of the colon and artefacts can to be useful in distinction of the polypoidal lesions from normal findings. The aim of this lecture is to describe common and less common pitfalls in CT colonography and to clarify features and CT criteria to distinction of organic formations from pseudo lesions. Inadequate preparation of the patient, weaknesses into the protocol, gaps and errors in interpretation are responsible for false positive and false negative results. The training which reduces the residual solids and liquid, marking, protocols elaboration and CAD allows achieving higher sensitivity and specificity. The 2D and 3D application techniques and solid knowledge about CT characteristic of the colon organic findings and pseudo lesions will reduce the rate of false positive results

  10. [Computer assisted orthognathic surgery: Condyle repositioning.

    Science.gov (United States)

    Bettega, G; Leitner, F

    2013-07-17

    Computer aided surgery has become a standard in many fields. It is rarely used in orthognathic surgery. Twenty years ago, we developed a navigation system adapted to this surgery, especially for mandibular condyle repositioning. The system has been improved along with technological progress. The authors of several clinical studies have validated this system. It is now routinely used in our department, because of its educational virtues among other assets. Copyright © 2013. Published by Elsevier Masson SAS.

  11. Imaging evaluation of post pancreatic surgery

    International Nuclear Information System (INIS)

    Scialpi, Michele; Scaglione, Mariano; Volterrani, Luca; Lupattelli, Luciano; Ragozzino, Alfonso; Romano, Stefania; Rotondo, Antonio

    2005-01-01

    The role of several imaging techniques in patients submitted to pancreatic surgery with special emphasis to single-slice helical computed tomography (CT) and multidetector-row CT (MDCT) was reviewed. Several surgical options may be performed such as Whipple procedure, distal pancreatectomy, central pancreatectomy, and total pancreatectomy. Ultrasound examination may be used to detect peritoneal fluid in the early post-operative period as well as lesion recurrence in long-term follow-up. Radiological gastrointestinal studies has a major role in evaluation of intestinal functionality. In spite of the advent of other imaging modalities, CT is the most effective after pancreatic surgery. On post-operative CT, the most common findings were small fluid peritoneal or pancreatic collections, stranding of the mesenteric fat with perivascular cuffing, reactive adenopathy and pneumobilia. In addition, CT may demonstrate early (leakage of anastomosis, pancreatico-jejunal fistula, haemorrage, acute pancreatitis of the remnant pancreas, peritonitis), and late (chronic fistula, abscess, aneurysms, anastomotic bilio-digestive stenosis, perianastomotic ulcers, biloma, and intra-abdominal bleeding) surgical complications. In the follow-up evaluation, CT may show tumor recurrence, liver and lymph nodes metastasis. Magnetic resonance may be used as alternative imaging modality to CT, when renal insufficiency or contrast sensitivity prevents the use of iodinated i.v. contrast material or when the biliary tree study is primarily requested. The knowledge of the type of surgical procedures, the proper identification of the anastomoses as well as the normal post-operative imaging appearances are essential for an accurate detection of the complications and recurrent disease

  12. Imaging evaluation of post pancreatic surgery

    Energy Technology Data Exchange (ETDEWEB)

    Scialpi, Michele [Department of Radiology, ' Santissima Annunziata' Hospital, Via Bruno 1, I-74100 Taranto (Italy)]. E-mail: michelescialpi@libero.it; Scaglione, Mariano [Department of Radiology, ' A. Cardarelli' Hospital, I-80131 Naples (Italy); Volterrani, Luca [Institute of Radiology, University of Siena, I-53100 Siena (Italy); Lupattelli, Luciano [Institute of Radiology, University of Perugia, I-06122 Perugia (Italy); Ragozzino, Alfonso [Department of Radiology, ' A. Cardarelli' Hospital, I-80131 Naples (Italy); Romano, Stefania [Department of Radiology, ' A. Cardarelli' Hospital, I-80131 Naples (Italy); Rotondo, Antonio [Section of Radiology, Department ' Magrassi-Lanzara' , Second University, I-80138 Naples (Italy)

    2005-03-01

    The role of several imaging techniques in patients submitted to pancreatic surgery with special emphasis to single-slice helical computed tomography (CT) and multidetector-row CT (MDCT) was reviewed. Several surgical options may be performed such as Whipple procedure, distal pancreatectomy, central pancreatectomy, and total pancreatectomy. Ultrasound examination may be used to detect peritoneal fluid in the early post-operative period as well as lesion recurrence in long-term follow-up. Radiological gastrointestinal studies has a major role in evaluation of intestinal functionality. In spite of the advent of other imaging modalities, CT is the most effective after pancreatic surgery. On post-operative CT, the most common findings were small fluid peritoneal or pancreatic collections, stranding of the mesenteric fat with perivascular cuffing, reactive adenopathy and pneumobilia. In addition, CT may demonstrate early (leakage of anastomosis, pancreatico-jejunal fistula, haemorrage, acute pancreatitis of the remnant pancreas, peritonitis), and late (chronic fistula, abscess, aneurysms, anastomotic bilio-digestive stenosis, perianastomotic ulcers, biloma, and intra-abdominal bleeding) surgical complications. In the follow-up evaluation, CT may show tumor recurrence, liver and lymph nodes metastasis. Magnetic resonance may be used as alternative imaging modality to CT, when renal insufficiency or contrast sensitivity prevents the use of iodinated i.v. contrast material or when the biliary tree study is primarily requested. The knowledge of the type of surgical procedures, the proper identification of the anastomoses as well as the normal post-operative imaging appearances are essential for an accurate detection of the complications and recurrent disease.

  13. Hereditary haemorrhagic telangiectasia: study of hepatic vascular alterations with multi-detector row helical CT and reconstruction programs; Telangiectasia emorragica ereditaria: TC multidetettore multifasica e programmi di ricostruzione nello studio delle alterazioni vascolari epatiche

    Energy Technology Data Exchange (ETDEWEB)

    Memeo, Maurizio; Stabile Ianora, Amato Antonio; Scaldapane, Arnaldo; Rotondo, Antonio; Angelelli, Giuseppe [Policlinico Universitario, Bari (Italy). DiMIMP Sezione di Diagnostica per Immagini; Suppressa, Patrizia; Cirulli, Anna; Sabba' , Carlo [Policlinico Universitario, Bari (Italy). Centro Interdipartimentale per lo studio dell' HHT

    2005-02-01

    Purpose: To evaluate hepatic alterations in patients affected by Hereditary Haemorrhagic Telangiectasia (HHT) by using multidetector row helical CT (MDCT) and new reconstruction programs. Materials and methods: An MDCT multiphasic study of the liver was performed in 105 consecutive patients: 89 considered to be affected by HHT and 16 with suspicion of disease alone. The scan delay was determined by using a test bolus of contrast material. The CT examination was performed with a triphasic technique (double arterial phase and portal venous phase). multiplanar and angiographic reconstructions were then obtained, and the images checked for the presence of shunts, hepatic perfusion disorders, vascular lesions (telangiectasis and large confluent vascular masses), indirect signs of portal hypertension, and anatomical vascular variants. Results: Hepatic vascular alterations were found in 78/105 cases (67/89) patients affected by HHT and 11/16 patients with clinical suspicion alone). Therefore HHT diagnosis was excluded in 5 patients. 78/100 (78%) patients with HHT had intrahepatic vascular alterations: arterioportal shunts in 40/78 (51.2%) arteriosystemic shunts in 16/78 (20.5%) and both shunt types in 22/78 (28.3%). Intraparenchymal perfusion disorders were found in 46/78 (58.9%) patients. Telangiectasis were recognised in 50/78 (64.1%) patients. Large confluent vascular masses (LCVMs) were identified in 20/78 (25.6%) patients. indirect signs of portal hypertension were found in 46/78 (58.9%) cases. Variant hepatic arterial anatomy was present in 38/100 cases (38%). Conclusions: Multiphasic MDCT and the new reconstruction programs enable the identification and characterisation of the complex vascular alterations typical of HHT. [Italian] Scopo: Valutare le alterazioni epatiche nei pazienti affetti da Telangiectasia Emorraica Ereditaria (TEE) utilizzando una TC multidetettore (TCMD) ed in nuovi programmi di ricostruzione. Materiale e metodi: E' stato eseguito uno

  14. Computed tomography-controlled stereotactic surgery

    International Nuclear Information System (INIS)

    Matsumoto, Keizo; Shichijo, Fumio; Gyoten, Tetsuya; Tomida, Keisuke; Miyake, Hajime

    1986-01-01

    A single use of coordinate system of computed tomography (CT) scanner is utilized for CT-controlled stereotactic surgery. Depth, direction and readjustment of target trajectory were defined by known values of cursor number in CT images and numbers of the sliding table indicator. We loaded calculation formulas into hand held computer to obtain immediate answers. Stereotactic apparatus consisted two main parts: the patient's head fixation and probe holder. Surgery was performed in cases of hypertensive intracerebral hemorrhage for evacuation of the hematomas successfully. Target accuracy was satisfactory. With further advance of this surgery, automatic stereotactic control with a special robot machine seeing possible. (author)

  15. Computational surgery and dual training computing, robotics and imaging

    CERN Document Server

    Bass, Barbara; Berceli, Scott; Collet, Christophe; Cerveri, Pietro

    2014-01-01

    This critical volume focuses on the use of medical imaging, medical robotics, simulation, and information technology in surgery. It offers a road map for computational surgery success,  discusses the computer-assisted management of disease and surgery, and provides a rational for image processing and diagnostic. This book also presents some advances on image-driven intervention and robotics, as well as evaluates models and simulations for a broad spectrum of cancers as well as cardiovascular, neurological, and bone diseases. Training and performance analysis in surgery assisted by robotic systems is also covered. This book also: ·         Provides a comprehensive overview of the use of computational surgery and disease management ·         Discusses the design and use of medical robotic tools for orthopedic surgery, endoscopic surgery, and prostate surgery ·         Provides practical examples and case studies in the areas of image processing, virtual surgery, and simulation traini...

  16. [Basic concept in computer assisted surgery].

    Science.gov (United States)

    Merloz, Philippe; Wu, Hao

    2006-03-01

    To investigate application of medical digital imaging systems and computer technologies in orthopedics. The main computer-assisted surgery systems comprise the four following subcategories. (1) A collection and recording process for digital data on each patient, including preoperative images (CT scans, MRI, standard X-rays), intraoperative visualization (fluoroscopy, ultrasound), and intraoperative position and orientation of surgical instruments or bone sections (using 3D localises). Data merging based on the matching of preoperative imaging (CT scans, MRI, standard X-rays) and intraoperative visualization (anatomical landmarks, or bone surfaces digitized intraoperatively via 3D localiser; intraoperative ultrasound images processed for delineation of bone contours). (2) In cases where only intraoperative images are used for computer-assisted surgical navigation, the calibration of the intraoperative imaging system replaces the merged data system, which is then no longer necessary. (3) A system that provides aid in decision-making, so that the surgical approach is planned on basis of multimodal information: the interactive positioning of surgical instruments or bone sections transmitted via pre- or intraoperative images, display of elements to guide surgical navigation (direction, axis, orientation, length and diameter of a surgical instrument, impingement, etc. ). And (4) A system that monitors the surgical procedure, thereby ensuring that the optimal strategy defined at the preoperative stage is taken into account. It is possible that computer-assisted orthopedic surgery systems will enable surgeons to better assess the accuracy and reliability of the various operative techniques, an indispensable stage in the optimization of surgery.

  17. Computer-assisted oral and maxillofacial surgery

    International Nuclear Information System (INIS)

    Hassfeld, S.; Brief, J.; Muehling, J.; Krempien, R.; Mende, U.; Raczkowsky, J.; Muenchenberg, J.; Woern, H.; Giess, H.; Meinzer, H.P.

    2000-01-01

    Background: Methods from the area of virtual reality are used in oral and maxillofacial surgery for the planning and three-dimensional individual simulation of surgeries. Simulation: In order to simulate complex surgeries with the aid of a computer, the diagnostic image data and especially various imaging modalities (CT, MRT, US) must be arranged in relation to each other, thus enabling rapid switching between the various modalities as well as the viewing of mixed images. Segmenting techniques for the reconstruction of three-dimensional representations of soft-tissue and osseous areas are required. We must develop ergonomic and intuitively useable interaction methods for the surgeon, thus allowing for precise and fast entry of the planned surgical intervention in the planning and simulation phase. Surgery: During the surgical phase, instrument navigation tools offer the surgeon interactive support through operation guidance and control of potential dangers. This feature is already available today. Future intraoperative assistance will take the form of such passive tools for the support of intraoperative orientation as well as so-called tracking systems (semi-active systems) which accompany and support the surgeons' work. The final form are robots which execute specific steps completely autonomously. Discussion: The techniques of virtual reality keep gaining in importance for medical applications. Many applications are still being developed or are still in the form of a prototype. However, it is already clear that developments in this area will have a considerable effect on the surgeon's routine work. (orig.) [de

  18. Multidetector Computed Tomography in the Preoperative Workup of Hilar Cholangiocarcinoma

    International Nuclear Information System (INIS)

    Kim, Hyoung Jung; Lee, Dong Ho; Lim, Joo Won; Ko, Young Tae

    2009-01-01

    Hilar cholangiocarcinoma is associated with a dismal prognosis; however, curative resection may offer a chance of cure. Various factors should be considered in the surgical planning for curative resection. These factors include extent of bile duct involvement, relationship between portal vein and tumor involvement, diffuse hepato duodenal ligament infiltration, vascular invasion, lymph node metastasis, peritoneal seeding, and hepatic volume. Using high-quality volume data from multidetector-row computed tomography (MDCT) and adequate postprocessing images, radiologists can provide various types of information, imperative for curative resection of a hilar cholangiocarcinoma. This review illustrates the role of MDCT in the preoperative workup of hilar cholangiocarcinoma

  19. Computer Assisted Orthopaedic Surgery – CAOS

    Directory of Open Access Journals (Sweden)

    Enes M. Kanlić

    2006-02-01

    Full Text Available The use of computer navigation in orthopedic surgery allows for real time intraoperative feedback resulting in higher precision of bone cuts, better alignment of implants and extremities, easier fracture reductions, less radiation and better documentation than what is possible in classical orthopaedic procedures. There is no need for direct and repeated visualization of many anatomical landmarks (classical method in order to have good intraoperative orientation. Navigation technology depicts anatomy and position of "smart tools" on the screen allowing for high surgical precision (smaller number of outliers from desired goal and with less soft tissue dissection (minimally invasive surgery - MIS. As a result, there are more happy patients with less pain, faster recovery, better functional outcome and well positioned, long lasting implants. In general, navigation cases are longer on the average 10 to 20 minutes, special training is required and equipment is relatively expensive. CAOS applications in knee and hip joint replacement are discussed.

  20. CARS 2008: Computer Assisted Radiology and Surgery. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-06-15

    The proceedings contain contributions to the following topics: digital imaging, computed tomography, magnetic resonance, cardiac and vascular imaging, computer assisted radiation therapy, image processing and display, minimal invasive spinal surgery, computer assisted treatment of the prostate, the interventional radiology suite of the future, interventional oncology, computer assisted neurosurgery, computer assisted head and neck and ENT surgery, cardiovascular surgery, computer assisted orthopedic surgery, image processing and visualization, surgical robotics, instrumentation and navigation, surgical modelling, simulation and education, endoscopy and related techniques, workflow and new concepts in surgery, research training group 1126: intelligent surgery, digital operating room, image distribution and integration strategies, regional PACS and telemedicine, PACS - beyond radiology and E-learning, workflow and standardization, breast CAD, thoracic CAD, abdominal CAD, brain CAD, orthodontics, dentofacial orthopedics and airways, imaging and treating temporomandibular joint conditions, maxillofacial cone beam CT, craniomaxillofacial image fusion and CBCT incidental findings, image guided craniomaxillofacial procedures, imaging as a biomarker for therapy response, computer aided diagnosis. The Poster sessions cover the topics computer aided surgery, Euro PACS meeting, computer assisted radiology, computer aided diagnosis and computer assisted radiology and surgery.

  1. CARS 2008: Computer Assisted Radiology and Surgery. Proceedings

    International Nuclear Information System (INIS)

    2008-01-01

    The proceedings contain contributions to the following topics: digital imaging, computed tomography, magnetic resonance, cardiac and vascular imaging, computer assisted radiation therapy, image processing and display, minimal invasive spinal surgery, computer assisted treatment of the prostate, the interventional radiology suite of the future, interventional oncology, computer assisted neurosurgery, computer assisted head and neck and ENT surgery, cardiovascular surgery, computer assisted orthopedic surgery, image processing and visualization, surgical robotics, instrumentation and navigation, surgical modelling, simulation and education, endoscopy and related techniques, workflow and new concepts in surgery, research training group 1126: intelligent surgery, digital operating room, image distribution and integration strategies, regional PACS and telemedicine, PACS - beyond radiology and E-learning, workflow and standardization, breast CAD, thoracic CAD, abdominal CAD, brain CAD, orthodontics, dentofacial orthopedics and airways, imaging and treating temporomandibular joint conditions, maxillofacial cone beam CT, craniomaxillofacial image fusion and CBCT incidental findings, image guided craniomaxillofacial procedures, imaging as a biomarker for therapy response, computer aided diagnosis. The Poster sessions cover the topics computer aided surgery, Euro PACS meeting, computer assisted radiology, computer aided diagnosis and computer assisted radiology and surgery

  2. Computer in surgery | Bode | Nigerian Journal of Surgical Research

    African Journals Online (AJOL)

    How has the advent of the computer impacted the field of surgery? Is it worth embracing for the older practitioners? What does the future portend for our ancient noble profession? This paper reviews current applications of computer technology in the field of surgery and the hopes it hold out to surgeons in developing ...

  3. Computed tomography angiogram. Accuracy in renal surgery

    International Nuclear Information System (INIS)

    Rabah, Danny M.; Al-Hathal, Naif; Al-Fuhaid, Turki; Raza, Sayed; Al-Yami, Fahad; Al-Taweel, Waleed; Alomar, Mohamed; Al-Nagshabandi, Nizar

    2009-01-01

    The objective of this study was to determine the sensitivity and specificity of computed tomography angiogram (CTA) in detecting number and location of renal arteries and veins as well as crossing vessels causing uretero-pelvic junction obstruction (UPJO), and to determine if this can be used in decision-making algorithms for treatment of UPJO. A prospective study was carried out in patients undergoing open, laparoscopic and robotic renal surgery from April 2005 until October 2006. All patients were imaged using CTA with 1.25 collimation of arterial and venous phases. Each multi-detector CTA was then read by one radiologist and his results were compared prospectively with the actual intra-operative findings. Overall, 118 patients were included. CTA had 93% sensitivity, 77% specificity and 90% overall accuracy for detecting a single renal artery, and 76% sensitivity, 92% specificity and 90% overall accuracy for detecting two or more renal arteries (Pearson χ 2 =0.001). There was 95% sensitivity, 84% specificity and 85% overall accuracy for detecting the number of renal veins. CTA had 100% overall accuracy in detecting early dividing renal artery (defined as less than 1.5 cm branching from origin), and 83.3% sensitivity, specificity and overall accuracy in detecting crossing vessels at UPJ. The percentage of surgeons stating CTA to be helpful as pre-operative diagnostic tool was 85%. Computed tomography angiogram is simple, quick and can provide an accurate pre-operative renal vascular anatomy in terms of number and location of renal vessels, early dividing renal arteries and crossing vessels at UPJ. (author)

  4. Computer assisted surgery in preoperative planning of acetabular fracture surgery: state of the art.

    Science.gov (United States)

    Boudissa, Mehdi; Courvoisier, Aurélien; Chabanas, Matthieu; Tonetti, Jérôme

    2018-01-01

    The development of imaging modalities and computer technology provides a new approach in acetabular surgery. Areas covered: This review describes the role of computer-assisted surgery (CAS) in understanding of the fracture patterns, in the virtual preoperative planning of the surgery and in the use of custom-made plates in acetabular fractures with or without 3D printing technologies. A Pubmed internet research of the English literature of the last 20 years was carried out about studies concerning computer-assisted surgery in acetabular fractures. The several steps for CAS in acetabular fracture surgery are presented and commented by the main author regarding to his personal experience. Expert commentary: Computer-assisted surgery in acetabular fractures is still initial experiences with promising results. Patient-specific biomechanical models considering soft tissues should be developed to allow a more realistic planning.

  5. CARS 2009. Computer assisted radiology and surgery. Proceedings

    International Nuclear Information System (INIS)

    Anon.

    2009-01-01

    The CARS 2009 proceedings include contributions and poster sessions concerning different conferences and workshops: computer assisted radiology, 23rd international congress and exhibition, CARS clinical day, 13th annual conference of the international society for computer aided surgery, 10th CARS/SPIE/EuroPACS joint workshop on surgical PACS and the digital operating, 11th international workshop on computer-aided diagnosis, 15th computed maxillofacial imaging congress, CARS - computer assisted radiology and surgery, 1st EPMA/CARS workshop on personalized medicine and ICT, JICARS - Japanese institutes of CARS, 1st EuroNotes/CTAC/CARS workshop on NOTES: an interdisciplinary challenge, 13th annual conference for computer aided surgery, 27th international EuroPACS meeting.

  6. Distant metastases and synchronous second primary tumors in patients with newly diagnosed oropharyngeal and hypopharyngeal carcinomas: evaluation of 18F-FDG PET and extended-field multi-detector row CT

    International Nuclear Information System (INIS)

    Ng, Shu-Hang; Ko, Sheung-Fat; Chin, Shu-Chyn; Chan, Sheng-Chieh; Yen, Tzu-Chen; Liao, Chun-Ta; Huang, Shiang-Fu; Chang, Joseph Tung-Chieh; Lin, Chin-Yu.; Wang, Hung-Ming

    2008-01-01

    Patients with oropharyngeal or hypopharyngeal squamous cell carcinoma (SCC) have a high risk of having distant metastases or second primary tumors. We prospectively evaluate the clinical usefulness of 18 F-fluoro-2-deoxyglucose positron emission tomography ( 18 F-FDG PET), extended-field multi-detector computed tomography (MDCT), and their side-by-side visual correlation for the detection of distant malignancies in these two tumors at presentation. A total of 160 patients with SCC of the oropharynx (n = 74) or hypopharynx (n=86) underwent 18 F-FDG PET and extended-field MDCT to detect distant metastases or second primary tumors. Suspected lesions were investigated by means of biopsy, clinical, or imaging follow-up. Twenty-six (16.3%) of our 160 patients were found to have distant malignancy. Diagnostic yields of 18 F-FDG PET and MDCT were 12.5% and 8.1%, respectively. The sensitivity of 18 F-FDG PET for detection of distant malignancies was 1.5-fold higher than that of MDCT (76.9% vs. 50.0%, P=0.039), while its specificity was slightly lower (94.0% vs. 97.8%, P=0.125). Side-by-side visual correlation of MDCT and 18 F-FDG PET improved the sensitivity and specificity up to 80.8% and 98.5%, respectively, leading to alteration of treatment in 13.1% of patients. A significant difference in survival rates between its positive and negative results was observed. 18 F-FDG PET and extended-field MDCT had acceptable diagnostic yields for detection of distant malignancies in untreated oropharyngeal and hypopharyngeal SCC. 18 F-FDG PET was 1.5-fold more sensitive than MDCT, but had more false-positive findings. Their visual correlation improved the diagnostic accuracy, treatment planning, and prognosis prediction. (orig.)

  7. Computed tomographic characteristics of collateral venous pathways in dogs with caudal vena cava obstruction.

    Science.gov (United States)

    Specchi, Swan; d'Anjou, Marc-André; Carmel, Eric Norman; Bertolini, Giovanna

    2014-01-01

    Collateral venous pathways develop in dogs with obstruction or increased blood flow resistance at any level of the caudal vena cava in order to maintain venous drainage to the right atrium. The purpose of this retrospective study was to describe the sites, causes of obstruction, and configurations of venous collateral pathways for a group of dogs with caudal vena cava obstruction. Computed tomography databases from two veterinary hospitals were searched for dogs with a diagnosis of caudal vena cava obstruction and multidetector row computed tomographic angiographic (CTA) scans that included the entire caudal vena cava. Images for each included dog were retrieved and collateral venous pathways were characterized using image postprocessing and a classification system previously reported for humans. A total of nine dogs met inclusion criteria and four major collateral venous pathways were identified: deep (n = 2), portal (n = 2), intermediate (n = 7), and superficial (n = 5). More than one collateral venous pathway was present in 5 dogs. An alternative pathway consisting of renal subcapsular collateral veins, arising mainly from the caudal pole of both kidneys, was found in three dogs. In conclusion, findings indicated that collateral venous pathway patterns similar to those described in humans are also present in dogs with caudal vena cava obstruction. These collateral pathways need to be distinguished from other vascular anomalies in dogs. Postprocessing of multidetector-row CTA images allowed delineation of the course of these complicated venous pathways and may be a helpful adjunct for treatment planning in future cases. © 2014 American College of Veterinary Radiology.

  8. Traumatic thoracic injury: the role of Multidetector-row CT

    International Nuclear Information System (INIS)

    Lim, Se Kyong; Shin, Kyung Sook; Kim, Ha Young; Sung, Jae Kyu; Jung, Hyun Yong; Noh, Seong Moo; Song, Kyu Sang; Cho, June Sik

    2006-01-01

    Hyperplastic polyps are common gastric lesions that are characterized by nonneoplastic epithelial hyperplasia. However, to our knowledge, there are no reports of a hyperplastic polyp arising from an endoscopic mucosectomy site of early gastric cancer. We describe the CT findings with a histopathology correlation in a case of a hyperplastic polyp arising from a mucosectomy site that mimicked polypoid gastric cancer

  9. Traumatic thoracic injury: the role of Multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Se Kyong; Shin, Kyung Sook; Kim, Ha Young; Sung, Jae Kyu; Jung, Hyun Yong; Noh, Seong Moo; Song, Kyu Sang; Cho, June Sik [Chungnam National University School of Medicine, Daejeon (Korea, Republic of)

    2006-05-15

    Hyperplastic polyps are common gastric lesions that are characterized by nonneoplastic epithelial hyperplasia. However, to our knowledge, there are no reports of a hyperplastic polyp arising from an endoscopic mucosectomy site of early gastric cancer. We describe the CT findings with a histopathology correlation in a case of a hyperplastic polyp arising from a mucosectomy site that mimicked polypoid gastric cancer.

  10. Data explosion: the challenge of multidetector-row CT

    International Nuclear Information System (INIS)

    Rubin, Geoffrey D.

    2000-01-01

    The development of multi detector-row CT has brought many exciting advancements to clinical CT scanning. While multi detector-row CT offers unparalleled speed of acquisition, spatial resolution, and anatomic coverage, a challenge presented by these advantages is the substantial increase on the number of reconstructed cross-sections that are rapidly created and in need of analysis. This manuscript discusses currently available alternative visualization techniques for the assessment of volumetric data acquired with multi detector-row CT. Although the current capabilities of 3-D workstations offer many possibilities for alternative analysis of MCDT data, substantial improvements both in automated processing, processing speed and user interface will be necessary to realize the vision of replacing the primary analysis of transverse reconstruction's with alternative analyses. The direction that some of these future developments might take are discussed

  11. Data explosion: the challenge of multidetector-row CT

    Energy Technology Data Exchange (ETDEWEB)

    Rubin, Geoffrey D. E-mail: grubin@standford.edu

    2000-11-01

    The development of multi detector-row CT has brought many exciting advancements to clinical CT scanning. While multi detector-row CT offers unparalleled speed of acquisition, spatial resolution, and anatomic coverage, a challenge presented by these advantages is the substantial increase on the number of reconstructed cross-sections that are rapidly created and in need of analysis. This manuscript discusses currently available alternative visualization techniques for the assessment of volumetric data acquired with multi detector-row CT. Although the current capabilities of 3-D workstations offer many possibilities for alternative analysis of MCDT data, substantial improvements both in automated processing, processing speed and user interface will be necessary to realize the vision of replacing the primary analysis of transverse reconstruction's with alternative analyses. The direction that some of these future developments might take are discussed.

  12. Current development of cardiac imaging with multidetector-row CT

    International Nuclear Information System (INIS)

    Becker, Christoph R.; Ohnesorge, Bernd M.; Schoepf, U. Joseph; Reiser, Maximilian F.

    2000-01-01

    Multidector-row CT (MDCT) with retrospective ECG gating allows scanning the entire heart with 1.25 mm slice thickness and 250 ms effective exposure time within 35 s investigation time. The resulting images allow for an accurate high-resolution assessment of morphological detail of both the coronary arteries and the cardiac chambers. Performing a contrast-enhanced MDCT angiography (MD-CTA) in addition to a non-enhanced scan for the detection and quantification of coronary calcifications may be indicated in patients with atypical chest pain and in young patients with high cardiovascular risk. This group of patients may show non-calcified plaques as the first sign of their coronary artery disease. As the proximal part of the coronary arteries is well displayed by MD-CTA it also helps to delineate the course in anomalous coronary vessels. Additional information is drawn from the preoperative use of MD-CTA do determine the distance of the left internal mammarian artery to the left anterior descending coronary artery prior to minimal invasive bypass grafting. Additional indications for MD-CTA are the non-invasive follow up after venous bypass grafting, PTCA, and coronary stent interventions. MD-CTA allows following the course of the coronary vessels to the level of third generation coronary segmental arteries. A definite diagnosis to rule out coronary artery disease can be reliably made in vessels with a diameter of 1.5 mm or greater. With MDCT a number of different atherosclerotic changes can be observed in diseased coronary arteries. Non-stenotic lesions may show tiny calcifications surrounded by large areas of irregularly distributed soft tissue. Calcifications in this type of atherosclerotic coronary artery wall changes appear as 'the tip of iceberg'. Heavy calcifications usually tend to be non-stenotic because of vessel remodelling resulting in a widening of the coronary vessel lumen. Therefore, heavy calcifications appear to act like an 'internal stent' for a coronary vessel segment. Humps of soft tissue either with or without calcifications are more likely to cause significant coronary artery disease and correlate with stenoses of >50% on selective coronary catheter. These humps consist of well-defined soft tissue in the coronary artery wall. The density of this soft tissue may vary between 30-70 HU. In cases where a coronary vessel is occluded by thrombotic material, a typical sign is found with enlargement of the coronary vessel, a hypodense center and a hyperdense rim. Vessel occlusion without thrombus may also appear within a collapsed and dense lumen. In addition to the investigation of the coronary arteries, CTA with MDCT is well suited to assess the presence and morphology of myocardial scars and aneurysms, intracardial tumors and thrombi

  13. Accuracy of computer-assisted orthognathic surgery.

    Science.gov (United States)

    De Riu, Giacomo; Virdis, Paola Ilaria; Meloni, Silvio Mario; Lumbau, Aurea; Vaira, Luigi Angelo

    2018-02-01

    The purpose of this study was to retrospectively evaluate the difference between the planned and the actual movements of the jaws, using three-dimensional (3D) software for PC-assisted orthognathic surgery, to establish the accuracy of the procedure. A retrospective study was performed with 49 patients who had undergone PC-guided bimaxillary surgery. The accuracy of the protocol was determined by comparing planned movements of the jaws with the actual surgical movements, analysing frontal and lateral cephalometries. The overall results were deemed accurate, and differences among 12 of the 15 parameters were considered nonsignificant. Significant differences were reported for SNA (p = 0.008), SNB (p = 0.006), and anterior facial height (p = 0.033). The latter was significantly different in patients who had undergone genioplasty when compared with patients who had not. Virtual surgical planning presented a good degree of accuracy for most of the parameters assessed, with an average error of 1.98 mm for linear measures and 1.19° for angular measures. In general, a tendency towards under-projection in jaws was detected, probably due to imperfect condylar seating. A slight overcorrection of SNA and SNB during virtual planning (approximately 2°) could be beneficial. Further progress is required in the development of 3D simulation of the soft tissue, which currently does not allow an accurate management of the facial height and the chin position. Virtual planning cannot replace the need for constant intraoperative monitoring of the jaws' movements and real-time comparisons between planned and actual outcomes. It is therefore appropriate to leave some margin for correction of inaccuracies in the virtual planning. In this sense, it may be appropriate to use only the intermediate splint, and then use the planned occlusion and clinical measurements to guide repositioning of the second jaw and chin, respectively. Copyright © 2017 European Association for Cranio

  14. Computed tomographic evaluation of realignment surgery for patellar subluxation

    International Nuclear Information System (INIS)

    Inoue, Masahiro; Shino, Konsei; Maeda, Akira; Nakata, Ken; Ono, Hiroo.

    1994-01-01

    Forty-two patients with patellar subluxation underwent realignment surgery of the knee extensor mechanism. The surgery included, lateral release, advancement and reefing of the vastus medialis and the medial capsule and tibial tubercle transfer (Elmslie-Trillat procedure). The effect of surgery was evaluated using computed tomograms of the pre- and post-operative knees at 0, 15, 30 and 45 degrees of knee flexion. The degree of patellofemoral incongruence on CT was expressed using two parameters of patellar tilt and patellar shift. Thirty-three volunteers without any patello-femoral symptoms served as controls. Postoperatively both the patellar tilt and the patellar shift improved significantly. The average patellar tilt and the patellar shift of the patient group at 45 degrees were comparable with those of controls. However, it was found by CT that the realignment surgery was less effective between 0 and 30 degrees of knee flexion. (author)

  15. Computed tomographic evaluation of realignment surgery for patellar subluxation

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Masahiro (Kansai Rosai Hospital, Amagasaki (Japan)); Shino, Konsei; Maeda, Akira; Nakata, Ken; Ono, Hiroo

    1994-01-01

    Forty-two patients with patellar subluxation underwent realignment surgery of the knee extensor mechanism. The surgery included, lateral release, advancement and reefing of the vastus medialis and the medial capsule and tibial tubercle transfer (Elmslie-Trillat procedure). The effect of surgery was evaluated using computed tomograms of the pre- and post-operative knees at 0, 15, 30 and 45 degrees of knee flexion. The degree of patellofemoral incongruence on CT was expressed using two parameters of patellar tilt and patellar shift. Thirty-three volunteers without any patello-femoral symptoms served as controls. Postoperatively both the patellar tilt and the patellar shift improved significantly. The average patellar tilt and the patellar shift of the patient group at 45 degrees were comparable with those of controls. However, it was found by CT that the realignment surgery was less effective between 0 and 30 degrees of knee flexion. (author).

  16. Towards ubiquitous access of computer-assisted surgery systems.

    Science.gov (United States)

    Liu, Hui; Lufei, Hanping; Shi, Weishong; Chaudhary, Vipin

    2006-01-01

    Traditional stand-alone computer-assisted surgery (CAS) systems impede the ubiquitous and simultaneous access by multiple users. With advances in computing and networking technologies, ubiquitous access to CAS systems becomes possible and promising. Based on our preliminary work, CASMIL, a stand-alone CAS server developed at Wayne State University, we propose a novel mobile CAS system, UbiCAS, which allows surgeons to retrieve, review and interpret multimodal medical images, and to perform some critical neurosurgical procedures on heterogeneous devices from anywhere at anytime. Furthermore, various optimization techniques, including caching, prefetching, pseudo-streaming-model, and compression, are used to guarantee the QoS of the UbiCAS system. UbiCAS enables doctors at remote locations to actively participate remote surgeries, share patient information in real time before, during, and after the surgery.

  17. Oral and maxillofacial surgery with computer-assisted navigation system.

    Science.gov (United States)

    Kawachi, Homare; Kawachi, Yasuyuki; Ikeda, Chihaya; Takagi, Ryo; Katakura, Akira; Shibahara, Takahiko

    2010-01-01

    Intraoperative computer-assisted navigation has gained acceptance in maxillofacial surgery with applications in an increasing number of indications. We adapted a commercially available wireless passive marker system which allows calibration and tracking of virtually every instrument in maxillofacial surgery. Virtual computer-generated anatomical structures are displayed intraoperatively in a semi-immersive head-up display. Continuous observation of the operating field facilitated by computer assistance enables surgical navigation in accordance with the physician's preoperative plans. This case report documents the potential for augmented visualization concepts in surgical resection of tumors in the oral and maxillofacial region. We report a case of T3N2bM0 carcinoma of the maxillary gingival which was surgically resected with the assistance of the Stryker Navigation Cart System. This system was found to be useful in assisting preoperative planning and intraoperative monitoring.

  18. 9th Asian Conference on Computer-Aided Surgery

    CERN Document Server

    2016-01-01

    This book presents the latest research advances in the theory, design, control, and application of robot systems intended for a variety of purposes such as manipulation, manufacturing, automation, surgery, locomotion, and biomechanics. Several chapters deal with fundamental kinematics in nature, including synthesis, calibration, redundancy, force control, dexterity, inverse and forward kinematics, kinematic singularities, and over-constrained systems. This book is a compilation of the extended versions of the very best papers selected from the many that were presented at the Asian Conference on Computer-Aided Surgery held September 16–18, 2013, in Tokyo, Japan (ACCAS 2013).

  19. Soft Tissue Biomechanical Modeling for Computer Assisted Surgery

    CERN Document Server

    2012-01-01

      This volume focuses on the biomechanical modeling of biological tissues in the context of Computer Assisted Surgery (CAS). More specifically, deformable soft tissues are addressed since they are the subject of the most recent developments in this field. The pioneering works on this CAS topic date from the 1980's, with applications in orthopaedics and biomechanical models of bones. More recently, however, biomechanical models of soft tissues have been proposed since most of the human body is made of soft organs that can be deformed by the surgical gesture. Such models are much more complicated to handle since the tissues can be subject to large deformations (non-linear geometrical framework) as well as complex stress/strain relationships (non-linear mechanical framework). Part 1 of the volume presents biomechanical models that have been developed in a CAS context and used during surgery. This is particularly new since most of the soft tissues models already proposed concern Computer Assisted Planning, with ...

  20. Computer aided surgery. Current status and future directions

    International Nuclear Information System (INIS)

    Sato, Yoshinobu

    2006-01-01

    This review describes topics in the title in the order of 3D model reconstruction and therapeutic planning based on images before surgery; registration of the actual images in virtual physical space of the patient who is under surgical operation, to the preoperative ones with use of 3D-position sensor, ultrasonics, endoscopy and X-diaphanoscopy; and their accuracy analysis. Images before surgery usually obtained with CT and MR are reconstructed in 3D for the purpose of therapeutic planning by segmentation of the target organ/site, surrounding organs, bones and blood vessels. Navigation system at the surgery functions to make the images obtained before and during operation to be integrated for their registration and displaying. Usually, the optical marker and camera both equipped in the endoscope, and position sensor (tracker) are used for integration in the operation coordinate system. For this, the actual pictures at liver operation are given. For accuracy analysis there is a theory of target registration error, which has been established on FDA demands. In future, development of technology concerned in this field like that of robot, bio-dynamics, biomaterials, sensor and high performance computing together with 4D document of surgery for feed-back to technology are desirable for the systematic growing of this surgical technology. (T.I.)

  1. Mechatronics Interface for Computer Assisted Prostate Surgery Training

    Science.gov (United States)

    Altamirano del Monte, Felipe; Padilla Castañeda, Miguel A.; Arámbula Cosío, Fernando

    2006-09-01

    In this work is presented the development of a mechatronics device to simulate the interaction of the surgeon with the surgical instrument (resectoscope) used during a Transurethral Resection of the Prostate (TURP). Our mechatronics interface is part of a computer assisted system for training in TURP, which is based on a 3D graphics model of the prostate which can be deformed and resected interactively by the user. The mechatronics interface, is the device that the urology residents will manipulate to simulate the movements performed during surgery. Our current prototype has five degrees of freedom, which are enough to have a realistic simulation of the surgery movements. Two of these degrees of freedom are linear, to determinate the linear displacement of the resecting loop and the other three are rotational to determinate three directions and amounts of rotation.

  2. Computer-assisted navigational surgery enhances safety in dental implantology.

    Science.gov (United States)

    Ng, F C; Ho, K H; Wexler, A

    2005-06-01

    Dental implants are increasingly used to restore missing dentition. These titanium implants are surgically installed in the edentulous alveolar ridge and allowed to osteointegrate with the bone during the healing phase. After osseo-integration, the implant is loaded with a prosthesis to replace the missing tooth. Conventional implant treatment planning uses study models, wax-ups and panoramic x-rays to prefabricate surgical stent to guide the preparation of the implant site. The drilling into the alveolar ridge is invariably a "blind" procedure as the part of the drill in bone is not visible. Stereotactic systems were first introduced into neurosurgery in 1986. Since then, computer-assisted navigational technology has brought major advances to neuro-, midface and orthopaedic surgeries, and more recently, to implant placement. This paper illustrates the use of real-time computer-guided navigational technology in enhancing safety in implant surgical procedures. Real-time computer-guided navigational technology enhances accuracy and precision of the surgical procedure, minimises complications and facilitates surgery in challenging anatomical locations.

  3. Normal postperative computed tomography findings after avariety of pancreatic surgeries

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Ji Won; Hwang, Ho Kyoung; Lee, Min Wook; Kim, Ki Whang; Kang, Chang Moo; Kim, Myeong Jin; Chung, Yong Eun [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Pancreatic surgery remains the only curative treatment for pancreatic neoplasms, and plays an important role in the management of medically intractable diseases. Since the original Whipple operation in the 20th century, surgical techniques have advanced, resulting in decreased postoperative complications and better clinical outcomes. Normal postoperative imaging findings vary greatly depending on the surgical technique used. Radiologists are required to be familiar with the normal postoperative imaging findings, in order to distinguish from postoperative complications or tumor recurrence. In this study, we briefly review a variety of surgical techniques for the pancreas, and present the normal postoperative computed tomography findings.

  4. Multidetector computer tomography in the pancreatic adenocarcinoma assessment: an update

    Directory of Open Access Journals (Sweden)

    Vincenza Granata

    2016-11-01

    Full Text Available Abstract Ductal adenocarcinoma of the pancreas is one of the most aggressive forms of cancer, with only a minority of cases being resectable at the moment of their diagnosis. The accurate detection and characterization of pancreatic carcinoma is very important for patient management. Multidetector-row computed tomography (MDCT has become the cross-sectional modality of choice in the diagnosis, staging, treatment planning, and follow-up of patients with pancreatic tumors. However, approximately 11% of ductal adenocarcinomas still remain undetected at MDCT because of the lack of attenuation gradient between the lesion and the adjacent pancreatic parenchyma. In this systematic literature review we investigate the current evolution of the CT technique, limitations, and perspectives in the evaluation of pancreatic carcinoma.

  5. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    International Nuclear Information System (INIS)

    Macedo, Clarissa Aguiar de; Baena, Marcos Eduardo da Silva; Uezumi, Kiyomi Kato; Castro, Claudio Campi de; Lucarelli, Claudio Luiz; Cerri, Giovanni Guido

    2008-01-01

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  6. Acute mediastinitis: multidetector computed tomography findings following cardiac surgery

    Energy Technology Data Exchange (ETDEWEB)

    Macedo, Clarissa Aguiar de [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Instituto do Coracao (InCor)]. E-mail: clarissaaguiarm@yahoo.com.br; Baena, Marcos Eduardo da Silva [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Ultrasonography; Uezumi, Kiyomi Kato [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Computed Tomography; Castro, Claudio Campi de [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Unit of Magnetic Resonance Imaging; Lucarelli, Claudio Luiz [Instituto do Coracao (InCor), Sao Paulo, SP (Brazil). Center of Diagnosis; Cerri, Giovanni Guido [Universidade de Sao Paulo (USP), SP (Brazil). School of Medicine. Dept. of Radiology

    2008-07-15

    Postoperative mediastinitis is defined as an infection of the organs and tissues in the mediastinal space, with an incidence ranging between 0.4% and 5% of cases. This disease severity varies from infection of superficial tissues in the chest wall to fulminant mediastinitis with sternal involvement. Diagnostic criterion for postoperative detection of acute mediastinitis at computed tomography is the presence of fluid collections and gas in the mediastinal space, which might or might not be associated with peristernal abnormalities such as edema of soft tissues, separation of sternal segments with marginal bone resorption, sclerosis and osteomyelitis. Other associated findings include lymphadenomegaly, pulmonary consolidation and pleural/ pericardial effusion. Some of these findings, such as mediastinal gas and small fluid collections can be typically found in the absence of infection, early in the period following thoracic surgery where the effectiveness of computed tomography is limited. After approximately two weeks, computed tomography achieves almost 100% sensitivity and specificity. Patients with clinical suspicion of mediastinitis should be submitted to computed tomography for investigating the presence of fluid collections to identify the extent and nature of the disease. Multidetector computed tomography allows 3D images reconstruction, contributing particularly to the evaluation of the sternum. (author)

  7. Computed tomography evaluation of autogenous graft in sinus lift surgery

    International Nuclear Information System (INIS)

    Ajzen, Sergio Aron; Moscatiello, Rafael Andrade; Lima, Aida Maria Custodio de; Moscatiello, Vitoria Aparecida Muglia; Helio Kiitiro Yamashita; Mosacatiello, Rafael Muglia; Nishiguchi, Celso Itiro; Alves, Maria Teresa de Seixas

    2001-01-01

    The objective was to quantify bone formation within autogenous bone grafts and autogenous bone grafts in combination with platelet-rich plasma obtained either from apheresis or centrifugation using computed tomography. This prospective, double-blind study was conducted in 34 male and female adult patients (mean age of 28 years and 8 months), with either unilateral or bilateral pneumatization of the maxillary sinuses, requiring bone graft for dental implant. All patients were submitted to computed tomography examinations prior and six months after sinus lift surgery. Fifty-three maxillary sinuses were operated and divided into three distinct groups: autogenous bone graft, autogenous bone graft in combination with platelet-rich plasma obtained by centrifugation, and autogenous bone graft in combination with platelet-rich plasma obtained by apheresis. The results showed that computed tomography demonstrated bone growth in height and width between the initial and the follow-up computed tomography scans in all three groups. However, no statistical difference was found either for bone height or width. It was concluded that clinical evidence demonstrates the effectiveness of autogenous bone grafts, particularly when used in combination with bone growth factors such as platelet-rich plasma, which allow prosthetic and functional restoration of maxillofacial structures through fixation of dental implants. (author)

  8. Computer-assisted Orthopaedic Surgery: Current State and Future Perspective

    Directory of Open Access Journals (Sweden)

    Guoyan eZheng

    2015-12-01

    Full Text Available Introduced about two decades ago, computer-assisted orthopaedic surgery (CAOS has emerged as a new and independent area, due to the importance of treatment of musculoskeletal diseases in orthopaedics and traumatology, increasing availability of different imaging modalities, and advances in analytics and navigation tools. The aim of this paper is to present the basic elements of CAOS devices and to review state-of-the-art examples of different imaging modalities used to create the virtual representations, of different position tracking devices for navigation systems, of different surgical robots, of different methods for registration and referencing, and of CAOS modules that have been realized for different surgical procedures. Future perspectives will also be outlined.

  9. [Clinical analysis of 12 cases of orthognathic surgery with digital computer-assisted technique].

    Science.gov (United States)

    Tan, Xin-ying; Hu, Min; Liu, Chang-kui; Liu, Hua-wei; Liu, San-xia; Tao, Ye

    2014-06-01

    This study was to investigate the effect of the digital computer-assisted technique in orthognathic surgery. Twelve patients from January 2008 to December 2011 with jaw malformation were treated in our department. With the help of CT and three-dimensional reconstruction technique, 12 patients underwent surgical treatment and the results were evaluated after surgery. Digital computer-assisted technique could clearly show the status of the jaw deformity and assist virtual surgery. After surgery all patients were satisfied with the results. Digital orthognathic surgery can improve the predictability of the surgical procedure, and to facilitate patients' communication, shorten operative time, and reduce patients' pain.

  10. Computer assisted orthopaedic and trauma surgery. State of the art and future perspectives

    NARCIS (Netherlands)

    Schep, N. W. L.; Broeders, I. A. M. J.; van der Werken, Chr

    2003-01-01

    In recent years computer technologies have become more and more integrated in surgical procedures. The potential advantages of computer assisted surgery (CAS) are: increase of accuracy of surgical interventions, less invasive operations, better planning and simulation and reduction of radiation

  11. Intra- and interobserver agreement of computed tomography in assessment of the mandibular condyle

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Bong Hae; Jung, Yun Hoa [Pusan National Univ. College of Dentistry, Pusan (Korea, Republic of)

    2007-12-15

    To study the intra- and interobserver agreement of multidetector row computed tomography (MDCT) in interpretation of degenerative changes of the mandibular condyle. Five observers independently evaluated one hundred temporomandibular joint MDCT images for signs of osteophytes, erosion, sclerosis and flattening. The intra- and interobserve agreements were calculated by using Kappa statistics. The intraobserver agreement was substantial for erosion (k=0.75), flattening (k=0.74) and sclerosis (k=0.72) and almost perfect for osteophytes (k=0.84). The interobserver agreement was fair for flattening (k=0.39), moderate for erosion (k=0.58) and sclerosis (k=0.48) and substantial for osteophytes (k=0.75). This study shows that we can expert good agreement for the presence of osteophytes, but not for flattening in the interpretation of MDCT images of the condyle.

  12. Modular multiple sensors information management for computer-integrated surgery.

    Science.gov (United States)

    Vaccarella, Alberto; Enquobahrie, Andinet; Ferrigno, Giancarlo; Momi, Elena De

    2012-09-01

    In the past 20 years, technological advancements have modified the concept of modern operating rooms (ORs) with the introduction of computer-integrated surgery (CIS) systems, which promise to enhance the outcomes, safety and standardization of surgical procedures. With CIS, different types of sensor (mainly position-sensing devices, force sensors and intra-operative imaging devices) are widely used. Recently, the need for a combined use of different sensors raised issues related to synchronization and spatial consistency of data from different sources of information. In this study, we propose a centralized, multi-sensor management software architecture for a distributed CIS system, which addresses sensor information consistency in both space and time. The software was developed as a data server module in a client-server architecture, using two open-source software libraries: Image-Guided Surgery Toolkit (IGSTK) and OpenCV. The ROBOCAST project (FP7 ICT 215190), which aims at integrating robotic and navigation devices and technologies in order to improve the outcome of the surgical intervention, was used as the benchmark. An experimental protocol was designed in order to prove the feasibility of a centralized module for data acquisition and to test the application latency when dealing with optical and electromagnetic tracking systems and ultrasound (US) imaging devices. Our results show that a centralized approach is suitable for minimizing synchronization errors; latency in the client-server communication was estimated to be 2 ms (median value) for tracking systems and 40 ms (median value) for US images. The proposed centralized approach proved to be adequate for neurosurgery requirements. Latency introduced by the proposed architecture does not affect tracking system performance in terms of frame rate and limits US images frame rate at 25 fps, which is acceptable for providing visual feedback to the surgeon in the OR. Copyright © 2012 John Wiley & Sons, Ltd.

  13. 76 FR 71980 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's...

    Science.gov (United States)

    2011-11-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-P-0176] SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's Petition for... SEDASYS computer-assisted personalized sedation system (SEDASYS) submitted by Ethicon Endo-Surgery Inc...

  14. Reduction of thoracic aorta motion artifact with high-pitch 128-slice dual-source computed tomographic angiography: a historical control study.

    Science.gov (United States)

    Nakagawa, Junichiro; Tasaki, Osamu; Watanabe, Yoshiyuki; Azuma, Takeo; Ohnishi, Mitsuo; Ukai, Isao; Tahara, Kenichi; Ogura, Hiroshi; Kuwagata, Yasuyuki; Hamasaki, Toshimitsu; Shimazu, Takeshi

    2013-01-01

    Electrocardiogram-gated imaging combined with multi-detector row computed tomography (MDCT) has reduced cardiac motion artifacts, but it was not practical in the emergency setting. The purpose of this study was to evaluate the ability of a high-pitch, 128-slice dual-source CT (DSCT) scanner to reduce motion artifacts in patients admitted to the emergency room. This study comprised 100 patients suspected of having thoracic aorta lesions. We examined 47 patients with the 128-slice DSCT scanner (DSCT group), and 53 patients were examined with a 64-slice MDCT scanner (MDCT group). Six anatomic areas in the thoracic aorta were evaluated. Computed tomography images in the DSCT group were distinct, and significant differences were observed in images of all areas between the 2 groups except for the descending aorta. The high-pitch DSCT scanner can reduce motion artifacts of the thoracic aorta and enable radiological diagnosis even in patients with tachycardia and without breath hold.

  15. [Computer-assisted navigation in orthognathic surgery. Application to Le Fort I osteotomy.

    Science.gov (United States)

    Benassarou, M; Benassarou, A; Meyer, C

    2013-08-05

    Computer-assisted navigation is a tool that allows the surgeon to reach intraoperatively a previously defined target. This technique can be applied to the positioning of bone fragments in orthognathic surgery. It is not used routinely yet because there are no specifically dedicated systems available on the market for this kind of surgery. The goal of our study was to describe the various systems that could be used in orthognathic surgery and to report our experience of computer-assisted surgery in the positioning of the maxilla during maxillomandibular osteotomies. Copyright © 2013. Published by Elsevier Masson SAS.

  16. MRI in 'failed back surgery syndrome': Comparison to computed tomography

    International Nuclear Information System (INIS)

    Trattnig, S.; Ungersboeck, K.; Cech, T.; Schindler, E.

    1990-01-01

    The term 'failed back surgery syndrome' (FBSS) includes a variety of clinical-neurological symptoms following disc surgery. In a prospective study 18 patients suffering from monoradicular symptoms after disc surgery were examined by MRI and CT (both prior to and following intravenous application of contrast material). Findings were then compared to microsurgery. MRI produced correct diagnoses in 17 cases, CT in 13 cases. Recurrent disc herniation caused symptoms four times, and epidural scar formation twice. In twelve cases there was herniated disc material as well as an epidural scar present; disc material preponderated nine times, scar formation in three instances. (orig.) [de

  17. Optical Head-Mounted Computer Display for Education, Research, and Documentation in Hand Surgery.

    Science.gov (United States)

    Funk, Shawn; Lee, Donald H

    2016-01-01

    Intraoperative photography and capturing videos is important for the hand surgeon. Recently, optical head-mounted computer display has been introduced as a means of capturing photographs and videos. In this article, we discuss this new technology and review its potential use in hand surgery. Copyright © 2016 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  18. Computer control versus manual control of systemic hypertension during cardiac surgery

    NARCIS (Netherlands)

    Hoeksel, S.A.A.P.; Blom, J.A.; Jansen, J.R.C.; Maessen, J.G.; Schreuder, J.J.

    2001-01-01

    Keywords:Cardiac surgery;hypertension;closed-loop controlBackground: We recently demonstrated the feasibility of computer controlled infusion of vasoactive drugs for the control of systemic hypertension during cardiac surgery. The objective of the current study was to investigate the effects of

  19. Radiologic anatomy of the paranasal sinuses in computed tomography for the need of the endoscopic surgery

    International Nuclear Information System (INIS)

    Boguslawska-Staniaszczyk, R.; Krzeski, A.; Mastalerski, J.

    1994-01-01

    Computed tomography is the most useful method in the endoscopic surgery of the nose and paranasal sinuses. CT examination is necessary for planing and the extent of the surgery. In this publication the method of CT examination and radiological anatomy of the nose and paranasal sinuses is described. (author)

  20. 76 FR 75887 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's...

    Science.gov (United States)

    2011-12-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-P-0176] SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Incorporated's Petition for... system (SEDASYS) submitted by Ethicon Endo-Surgery Inc. (EES), the sponsor for SEDASYS. This meeting has...

  1. Quantification of Global Left Ventricular Function: Comparison of Multidetector Computed Tomography and Magnetic Resonance Imaging. A Meta-analysis and Review of the Current Literature

    International Nuclear Information System (INIS)

    Vleuten, P.A. van der; Willems, T.P.; Goette, M.J.; Tio, R.A.; Greuter, M.J.; Zijlstra, F.; Oudkerk, M.

    2006-01-01

    Cardiac morbidity and mortality are closely related to cardiac volumes and global left ventricular (LV) function, expressed as left ventricular ejection fraction. Accurate assessment of these parameters is required for the prediction of prognosis in individual patients as well as in entire cohorts. The current standard of reference for left ventricular function is analysis by short-axis magnetic resonance imaging. In recent years, major extensive technological improvements have been achieved in computed tomography. The most marked development has been the introduction of the multidetector CT (MDCT), which has significantly improved temporal and spatial resolutions. In order to assess the current status of MDCT for analysis of LV function, the current available literature on this subject was reviewed. The data presented in this review indicate that the global left ventricular functional parameters measured by contemporary multi-detector row systems combined with adequate reconstruction algorithms and post-processing tools show a narrow diagnostic window and are interchangeable with those obtained by MRI

  2. Computer Simulation and Digital Resources for Plastic Surgery Psychomotor Education.

    Science.gov (United States)

    Diaz-Siso, J Rodrigo; Plana, Natalie M; Stranix, John T; Cutting, Court B; McCarthy, Joseph G; Flores, Roberto L

    2016-10-01

    Contemporary plastic surgery residents are increasingly challenged to learn a greater number of complex surgical techniques within a limited period. Surgical simulation and digital education resources have the potential to address some limitations of the traditional training model, and have been shown to accelerate knowledge and skills acquisition. Although animal, cadaver, and bench models are widely used for skills and procedure-specific training, digital simulation has not been fully embraced within plastic surgery. Digital educational resources may play a future role in a multistage strategy for skills and procedures training. The authors present two virtual surgical simulators addressing procedural cognition for cleft repair and craniofacial surgery. Furthermore, the authors describe how partnerships among surgical educators, industry, and philanthropy can be a successful strategy for the development and maintenance of digital simulators and educational resources relevant to plastic surgery training. It is our responsibility as surgical educators not only to create these resources, but to demonstrate their utility for enhanced trainee knowledge and technical skills development. Currently available digital resources should be evaluated in partnership with plastic surgery educational societies to guide trainees and practitioners toward effective digital content.

  3. Legal issues of computer imaging in plastic surgery: a primer.

    Science.gov (United States)

    Chávez, A E; Dagum, P; Koch, R J; Newman, J P

    1997-11-01

    Although plastic surgeons are increasingly incorporating computer imaging techniques into their practices, many fear the possibility of legally binding themselves to achieve surgical results identical to those reflected in computer images. Computer imaging allows surgeons to manipulate digital photographs of patients to project possible surgical outcomes. Some of the many benefits imaging techniques pose include improving doctor-patient communication, facilitating the education and training of residents, and reducing administrative and storage costs. Despite the many advantages computer imaging systems offer, however, surgeons understandably worry that imaging systems expose them to immense legal liability. The possible exploitation of computer imaging by novice surgeons as a marketing tool, coupled with the lack of consensus regarding the treatment of computer images, adds to the concern of surgeons. A careful analysis of the law, however, reveals that surgeons who use computer imaging carefully and conservatively, and adopt a few simple precautions, substantially reduce their vulnerability to legal claims. In particular, surgeons face possible claims of implied contract, failure to instruct, and malpractice from their use or failure to use computer imaging. Nevertheless, legal and practical obstacles frustrate each of those causes of actions. Moreover, surgeons who incorporate a few simple safeguards into their practice may further reduce their legal susceptibility.

  4. A review of computer-aided oral and maxillofacial surgery: planning, simulation and navigation.

    Science.gov (United States)

    Chen, Xiaojun; Xu, Lu; Sun, Yi; Politis, Constantinus

    2016-11-01

    Currently, oral and maxillofacial surgery (OMFS) still poses a significant challenge for surgeons due to the anatomic complexity and limited field of view of the oral cavity. With the great development of computer technologies, he computer-aided surgery has been widely used for minimizing the risks and improving the precision of surgery. Areas covered: The major goal of this paper is to provide a comprehensive reference source of current and future development of computer-aided OMFS including surgical planning, simulation and navigation for relevant researchers. Expert commentary: Compared with the traditional OMFS, computer-aided OMFS overcomes the disadvantage that the treatment on the region of anatomically complex maxillofacial depends almost exclusively on the experience of the surgeon.

  5. Multi-slice computed tomography-assisted endoscopic transsphenoidal surgery for pituitary macroadenoma: a comparison with conventional microscopic transsphenoidal surgery.

    Science.gov (United States)

    Tosaka, Masahiko; Nagaki, Tomohito; Honda, Fumiaki; Takahashi, Katsumasa; Yoshimoto, Yuhei

    2015-11-01

    Intraoperative computed tomography (iCT) is a reliable method for the detection of residual tumour, but previous single-slice low-resolution computed tomography (CT) without coronal or sagittal reconstructions was not of adequate quality for clinical use. The present study evaluated the results of multi-slice iCT-assisted endoscopic transsphenoidal surgery for pituitary macroadenoma. This retrospective study included 30 consecutive patients with newly diagnosed or recurrent pituitary macroadenoma with supradiaphragmatic extension who underwent endoscopic transsphenoidal surgery using iCT (eTSS+iCT group), and control 30 consecutive patients who underwent conventional endoscope-assisted transsphenoidal surgery (cTSS group). The tumour volume was calculated by multiplying the tumour area by the slice thickness. Visual acuity and visual field were estimated by the visual impairment score (VIS). The resection extent, (preoperative tumour volume - postoperative residual tumour volume)/preoperative tumour volume, was 98.9% (median) in the eTSS+iCT group and 91.7% in the cTSS group, and had significant difference between the groups (P = 0.04). Greater than 95 and >90% removal rates were significantly higher in the eTSS+iCT group than in the cTSS group (P = 0.02 and P = 0.001, respectively). However, improvement in VIS showed no significant difference between the groups. The rate of complications also showed no significant difference. Multi-slice iCT-assisted endoscopic transsphenoidal surgery may improve the resection extent of pituitary macroadenoma. Multi-slice iCT may have advantages over intraoperative magnetic resonance imaging in less expensive, short acquisition time, and that special protection against magnetic fields is not needed.

  6. Computer assisted surgery for malunited fractures in upper limb

    International Nuclear Information System (INIS)

    Yoneda, Masahiro; Kazuki, Kenichi; Uemura, Takuya; Okada, Mitsuhiro; Takaoka, Kunio

    2006-01-01

    Our objective was to evaluate the usefulness of computer-assisted preoperative simulation of malunited fractures in the upper limb. Ten patients with malunited fractures underwent multislice computed tomography of both upper limbs with reconstruction of three-dimensional bone models using three-dimensional (3D) software. Preoperative simulation was comprised of four main procedures: performance of virtual corrective osteotomy, matching of reposition with a mirror-image model of the unaffected side, creating new data for the bone defect, and machining of an hydroxyapatite block as bone graft. In addition, we used full-sized three-dimensional virtual reality modeling with a rapid prototyping molding device, and performed preoperative rehearsals of osteotomies using plaster models. All patients tolerated the surgical procedure well. This technique permits the surgeon to recognize and correct three-dimensional deformities of malunited fracture with both accuracy and precision. (author)

  7. Easy computer assisted teaching method for undergraduate surgery

    OpenAIRE

    Agrawal, Vijay P

    2015-01-01

    Use of computers to aid or support the education or training of people has become commonplace in medical education. Recent studies have shown that it can improve learning outcomes in diagnostic abilities, clinical skills and knowledge across different learner levels from undergraduate medical education to continuing medical education. It also enhance the educational process by increasing access to learning materials, standardising the educational process, providing opportunities for asynchron...

  8. Towards computer-assisted surgery in shoulder joint replacement

    Science.gov (United States)

    Valstar, Edward R.; Botha, Charl P.; van der Glas, Marjolein; Rozing, Piet M.; van der Helm, Frans C. T.; Post, Frits H.; Vossepoel, Albert M.

    A research programme that aims to improve the state of the art in shoulder joint replacement surgery has been initiated at the Delft University of Technology. Development of improved endoprostheses for the upper extremities (DIPEX), as this effort is called, is a clinically driven multidisciplinary programme consisting of many contributory aspects. A part of this research programme focuses on the pre-operative planning and per-operative guidance issues. The ultimate goal of this part of the DIPEX project is to create a surgical support infrastructure that can be used to predict the optimal surgical protocol and can assist with the selection of the most suitable endoprosthesis for a particular patient. In the pre-operative planning phase, advanced biomechanical models of the endoprosthesis fixation and the musculo-skeletal system of the shoulder will be incorporated, which are adjusted to the individual's morphology. Subsequently, the support infrastructure must assist the surgeon during the operation in executing his surgical plan. In the per-operative phase, the chosen optimal position of the endoprosthesis can be realised using camera-assisted tools or mechanical guidance tools. In this article, the pathway towards the desired surgical support infrastructure is described. Furthermore, we discuss the pre-operative planning phase and the per-operative guidance phase, the initial work performed, and finally, possible approaches for improving prosthesis placement.

  9. A computer assisted toolholder to guide surgery in stereotactic space.

    Science.gov (United States)

    Giorgi, C; Pluchino, F; Luzzara, M; Ongania, E; Casolino, D S

    1994-01-01

    A computer assisted toolholder, integrated with an anatomical graphic 3-D rendering programme, is presented. Stereotactic neuroanatomical images are acquired, and the same reference system is employed to represent the position of the toolholder on the monitor. The surgeon can check the orientation of different approach trajectories, moving the toolholder in a situation of virtual reality. Angular values expressed by high precision encoders on the five joints of the toolholder modify "on line" the representation of the configuration of the toolholder within the three dimensional representation of the patient's anatomy.

  10. Computer simulation of orthognathic surgery with video imaging

    Science.gov (United States)

    Sader, Robert; Zeilhofer, Hans-Florian U.; Horch, Hans-Henning

    1994-04-01

    Patients with extreme jaw imbalance must often undergo operative corrections. The goal of therapy is to harmonize the stomatognathic system and an aesthetical correction of the face profile. A new procedure will be presented which supports the maxillo-facial surgeon in planning the operation and which also presents the patient the result of the treatment by video images. Once an x-ray has been digitized it is possible to produce individualized cephalometric analyses. Using a ceph on screen, all current orthognathic operations can be simulated, whereby the bony segments are moved according to given parameters, and a new soft tissue profile can be calculated. The profile of the patient is fed into the computer by way of a video system and correlated to the ceph. Using the simulated operation the computer calculates a new video image of the patient which presents the expected postoperative appearance. In studies of patients treated between 1987-91, 76 out of 121 patients were able to be evaluated. The deviation in profile change varied between .0 and 1.6mm. A side effect of the practical applications was an increase in patient compliance.

  11. Computational aspects in high intensity ultrasonic surgery planning.

    Science.gov (United States)

    Pulkkinen, A; Hynynen, K

    2010-01-01

    Therapeutic ultrasound treatment planning is discussed and computational aspects regarding it are reviewed. Nonlinear ultrasound simulations were solved with a combined frequency domain Rayleigh and KZK model. Ultrasonic simulations were combined with thermal simulations and were used to compute heating of muscle tissue in vivo for four different focused ultrasound transducers. The simulations were compared with measurements and good agreement was found for large F-number transducers. However, at F# 1.9 the simulated rate of temperature rise was approximately a factor of 2 higher than the measured ones. The power levels used with the F# 1 transducer were too low to show any nonlinearity. The simulations were used to investigate the importance of nonlinarities generated in the coupling water, and also the importance of including skin in the simulations. Ignoring either of these in the model would lead to larger errors. Most notably, the nonlinearities generated in the water can enhance the focal temperature by more than 100%. The simulations also demonstrated that pulsed high power sonications may provide an opportunity to significantly (up to a factor of 3) reduce the treatment time. In conclusion, nonlinear propagation can play an important role in shaping the energy distribution during a focused ultrasound treatment and it should not be ignored in planning. However, the current simulation methods are accurate only with relatively large F-numbers and better models need to be developed for sharply focused transducers. Copyright 2009 Elsevier Ltd. All rights reserved.

  12. 76 FR 15321 - SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Inc.'s, Petition...

    Science.gov (United States)

    2011-03-21

    ...] SEDASYS Computer-Assisted Personalized Sedation System; Ethicon Endo-Surgery, Inc.'s, Petition for Review... an advisory committee Ethicon Endo- Surgery Inc.'s (EES's), petition for review of the Agency's... Foreman, FDA, CDRH, to Ken Charak, Ethicon Endo-Surgery, Inc., containing the order denying approval of...

  13. [Possibilities of computer graphics simulation in orthopedic surgery].

    Science.gov (United States)

    Kessler, P; Wiltfang, J; Teschner, M; Girod, B; Neukam, F W

    2000-11-01

    In addition to standard X-rays, photographic documentation, cephalometric and model analysis, a computer-aided, three-dimensional (3D) simulation system has been developed in close cooperation with the Institute of Communications of the Friedrich-Alexander-Universität Erlangen-Nürnberg. With this simulation system a photorealistic prediction of the expected soft tissue changes can be made. Prerequisites are a 3D reconstruction of the facial skeleton and a 3D laser scan of the face. After data reduction, the two data sets can be matched. Cutting planes enable the transposition of bony segments. The laser scan of the facial surface is combined with the underlying bone via a five-layered soft tissue model to convert bone movements on the soft tissue cover realistically. Further research is necessary to replace the virtual subcutaneous soft tissue model by correct, topographic tissue anatomy.

  14. [Guided and computer-assisted implant surgery and prosthetic: The continuous digital workflow].

    Science.gov (United States)

    Pascual, D; Vaysse, J

    2016-02-01

    New continuous digital workflow protocols of guided and computer-assisted implant surgery improve accuracy of implant positioning. The design of the future prosthesis is based on the available prosthetic space, gingival height and occlusal relationship with the opposing and adjacent teeth. The implant position and length depend on volume, density and bone quality, gingival height, tooth-implant and implant-implant distances, implant parallelism, axis and type of the future prosthesis. The crown modeled on the software will therefore serve as a guide to the future implant axis and not the reverse. The guide is made by 3D printing. The software determines surgical protocol with the drilling sequences. The unitary or plural prosthesis, modeled on the software and built before surgery, is loaded directly after implant placing, if needed. These protocols allow for a full continuity of the digital workflow. The software provides the surgeon and the dental technician a total freedom for the prosthetic-surgery guide design and the position of the implants. The prosthetic project, occlusal and aesthetic, taking the bony and surgical constraints into account, is optimized. The implant surgery is simplified and becomes less "stressful" for the patient and the surgeon. Guided and computer-assisted surgery with continuous digital workflow is becoming the technique of choice to improve the accuracy and quality of implant rehabilitation. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  15. Interactive virtual simulation using a 3D computer graphics model for microvascular decompression surgery.

    Science.gov (United States)

    Oishi, Makoto; Fukuda, Masafumi; Hiraishi, Tetsuya; Yajima, Naoki; Sato, Yosuke; Fujii, Yukihiko

    2012-09-01

    The purpose of this paper is to report on the authors' advanced presurgical interactive virtual simulation technique using a 3D computer graphics model for microvascular decompression (MVD) surgery. The authors performed interactive virtual simulation prior to surgery in 26 patients with trigeminal neuralgia or hemifacial spasm. The 3D computer graphics models for interactive virtual simulation were composed of the brainstem, cerebellum, cranial nerves, vessels, and skull individually created by the image analysis, including segmentation, surface rendering, and data fusion for data collected by 3-T MRI and 64-row multidetector CT systems. Interactive virtual simulation was performed by employing novel computer-aided design software with manipulation of a haptic device to imitate the surgical procedures of bone drilling and retraction of the cerebellum. The findings were compared with intraoperative findings. In all patients, interactive virtual simulation provided detailed and realistic surgical perspectives, of sufficient quality, representing the lateral suboccipital route. The causes of trigeminal neuralgia or hemifacial spasm determined by observing 3D computer graphics models were concordant with those identified intraoperatively in 25 (96%) of 26 patients, which was a significantly higher rate than the 73% concordance rate (concordance in 19 of 26 patients) obtained by review of 2D images only (p computer graphics model provided a realistic environment for performing virtual simulations prior to MVD surgery and enabled us to ascertain complex microsurgical anatomy.

  16. Use of computer-based clinical examination to assess medical students in surgery.

    Science.gov (United States)

    El Shallaly, Gamal E H A; Mekki, Abdelrahman M

    2012-01-01

    To improve the viewing of the video-projected structured clinical examination (ViPSCE), we developed a computerized version; the computer-based clinical examination (CCE). This was used to assess medical students' higher knowledge and problem solving skills in surgery. We present how we did this, test score descriptive statistics, and the students' evaluation of the CCE. A CCE in surgery was administered to assess a class of 43 final year medical students at the end of their surgical clerkship. Like the ViPSCE, the exam was delivered as a slide show, using a PowerPoint computer program. However, instead of projecting it onto a screen, each student used a computer. There were 20 slides containing either still photos or short video clips of clinical situations in surgery. The students answered by hand writing on the exam papers. At the end, they completed evaluation forms. The exam papers were corrected manually. Test score descriptive statistics were calculated and correlated with the students' scores in other exams in surgery. Administration of the CCE was straightforward. The test scores were normally distributed (mean = median = 4.9). They correlated significantly with the total scores obtained by the students in surgery (r = 0.68), and with each of the other exam modalities in surgery, such as the multiple choice and structured essay questions. Acceptability of the CCE to the students was high and they recommended the use of the CCE in other departments. CCE is feasible and popular with students. It inherits the validity and reliability of the ViPSCE with the added advantage of improving the viewing of the slides.

  17. Computer-based endoscopic image-processing technology for endourology and laparoscopic surgery

    International Nuclear Information System (INIS)

    Igarashi, Tatsuo; Suzuki, Hiroyoshi; Naya, Yukio

    2009-01-01

    Endourology and laparoscopic surgery are evolving in accordance with developments in instrumentation and progress in surgical technique. Recent advances in computer and image-processing technology have enabled novel images to be created from conventional endoscopic and laparoscopic video images. Such technology harbors the potential to advance endourology and laparoscopic surgery by adding new value and function to the endoscope. The panoramic and three-dimensional images created by computer processing are two outstanding features that can address the shortcomings of conventional endoscopy and laparoscopy, such as narrow field of view, lack of depth cue, and discontinuous information. The wide panoramic images show an anatomical map' of the abdominal cavity and hollow organs with high brightness and resolution, as the images are collected from video images taken in a close-up manner. To assist in laparoscopic surgery, especially in suturing, a three-dimensional movie can be obtained by enhancing movement parallax using a conventional monocular laparoscope. In tubular organs such as the prostatic urethra, reconstruction of three-dimensional structure can be achieved, implying the possibility of a liquid dynamic model for assessing local urethral resistance in urination. Computer-based processing of endoscopic images will establish new tools for endourology and laparoscopic surgery in the near future. (author)

  18. Digital Workflow for Computer-Guided Implant Surgery in Edentulous Patients: A Case Report.

    Science.gov (United States)

    Oh, Ji-Hyeon; An, Xueyin; Jeong, Seung-Mi; Choi, Byung-Ho

    2017-12-01

    The purpose of this article was to describe a fully digital workflow used to perform computer-guided flapless implant placement in an edentulous patient without the use of conventional impressions, models, or a radiographic guide. Digital data for the workflow were acquired using an intraoral scanner and cone-beam computed tomography (CBCT). The image fusion of the intraoral scan data and CBCT data was performed by matching resin markers placed in the patient's mouth. The definitive digital data were used to design a prosthetically driven implant position, surgical template, and computer-aided design and computer-aided manufacturing fabricated fixed dental prosthesis. The authors believe this is the first published case describing such a technique in computer-guided flapless implant surgery for edentulous patients. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Clinical application of 3D computer simulation for upper limb surgery

    International Nuclear Information System (INIS)

    Murase, Tsuyoshi; Moritomo, Hisao; Oka, Kunihiro; Arimitsu, Sayuri; Shimada, Kozo

    2008-01-01

    To perform precise orthopaedic surgery, we have been developing a surgical method using a custom-made surgical device designed based on preoperative three-dimensional computer simulation. The purpose of this study was to investigate the preliminary results of its clinical application for corrective osteotomy of the upper extremity. Twenty patients with long bone deformities of the upper extremities (four cubitus varus deformities, nine malunited forearm fractures, six malunited distal radial fractures and one congenital deformity of the forearm) participated in this study. Three-dimensional computer models of the affected bone and the contralateral normal bone were constructed from computed tomography data. By comparing these models, the three-dimensional deformity axis and the accurate amount of deformity around it were quantified. Three-dimensional deformity correction was then simulated. A custom-made osteotomy template was designed and manufactured as a real plastic model aiming to reproduce the preoperative simulation in the actual operation. In the operation, we put the template on the bone surface, cut the bone through a slit on the template, and corrected the deformity as preoperatively simulated, followed by internal fixation. Radiographic and clinical evaluations were made in all cases before surgery and at the most recent follow-up. Corrective osteotomy was achieved as simulated in all cases. All patients had bone fusion within six months. Regarding the cubitus varus deformity, the average carrying angle and tilting angle were 5deg and 28deg after surgery. For malunited forearm fractures, angular deformities on radiographs were nearly nonexistent after surgery. All radiographic parameters in malunited distal radius fractures were normalized. The range of forearm rotation in cases of forearm malunion and that of wrist flexion-extension in cases of malunited distal radius improved after surgery. (author)

  20. Computer Assisted Surgery and Current Trends in Orthopaedics Research and Total Joint Replacements

    Science.gov (United States)

    Amirouche, Farid

    2008-06-01

    Musculoskeletal research has brought about revolutionary changes in our ability to perform high precision surgery in joint replacement procedures. Recent advances in computer assisted surgery as well better materials have lead to reduced wear and greatly enhanced the quality of life of patients. The new surgical techniques to reduce the size of the incision and damage to underlying structures have been the primary advance toward this goal. These new techniques are known as MIS or Minimally Invasive Surgery. Total hip and knee Arthoplasties are at all time high reaching 1.2 million surgeries per year in the USA. Primary joint failures are usually due to osteoarthristis, rheumatoid arthritis, osteocronis and other inflammatory arthritis conditions. The methods for THR and TKA are critical to initial stability and longevity of the prostheses. This research aims at understanding the fundamental mechanics of the joint Arthoplasty and providing an insight into current challenges in patient specific fitting, fixing, and stability. Both experimental and analytical work will be presented. We will examine Cementless total hip arthroplasty success in the last 10 years and how computer assisted navigation is playing in the follow up studies. Cementless total hip arthroplasty attains permanent fixation by the ingrowth of bone into a porous coated surface. Loosening of an ingrown total hip arthroplasty occurs as a result of osteolysis of the periprosthetic bone and degradation of the bone prosthetic interface. The osteolytic process occurs as a result of polyethylene wear particles produced by the metal polyethylene articulation of the prosthesis. The total hip arthroplasty is a congruent joint and the submicron wear particles produced are phagocytized by macrophages initiating an inflammatory cascade. This cascade produces cytokines ultimately implicated in osteolysis. Resulting bone loss both on the acetabular and femoral sides eventually leads to component instability. As

  1. Valuation of using saline flush technique of contrast medium on abdominal multidetector row CT scanning

    International Nuclear Information System (INIS)

    Zhao Hong; Wang Ying; He Yanli; Liu Xiaobing; Bao Shiliang; Han Mingjun

    2006-01-01

    Objective: The purpose of this study was to compare the enhancement degree of abdomen organs and vessels after different amount of contrast medium using saline flush in abdomen MDCT scanning, which aimed to not affect contrast enhancement, decreased the amount of contrast medium, and reduced the side-effect. Methods: This study group consisted of 75 patients who were referred for contrast enhanced abdominal MDCT for various reasons. Patients were allocated into three groups: injection of 100ml of contrast medium only (A group), injection of 80ml pushed with 20ml of saline solution (B group), and injection of 70ml pushed with 30ml of saline solution (C group). Attenuation values were measured from the liver, spleen, pancreas, kidney, aorta, portal vein, and inferior vena cava in 33 second and 80 second of imaging after injection contrast medium. Results: The portal venous phases of the spleen, pancreas, kidney, aorta, portal vein had statistically significant difference among groups A, B and C. Post hoc test showed statistically significant difference between A group and C group, But no statistically significant difference during the portal venous phases of the pancreas and the kidney between A group and B group. Conclusion: Using a saline flush technique after the injection contrast medium in abdominal MDCT reduced waste of contrast medium and decrease in nephrotoxicity, at the same time, it would not lose important diagnostic information and saved patients cost for the contrast medium. (authors)

  2. Current status of multi-detector row helical CT in imaging of adult ...

    African Journals Online (AJOL)

    Mary Y. Tadros

    2016-06-22

    Jun 22, 2016 ... Pancreatic cancer is one of the most lethal diseases, with a poor prognosis. .... pseudocyst, pancreatic abscess, and inflammatory changes of ..... metastasize to the pancreas are from lung, breast, kidney, and melanoma.

  3. The effects of misinterpretation of an artefact on multidetector row CT scans in children

    Energy Technology Data Exchange (ETDEWEB)

    Du Plessis, Anne-Marie; Theron, Salomine; Andronikou, Savvas [University of Stellenbosch, Radiology Department, Tygerberg Hospital, Cape Town (South Africa)

    2009-02-15

    Artefacts reflect problems with radiographic technique rather than true pathology. These may be misinterpreted as pathology with serious consequences. An artefact caused such problems in one paediatric imaging department. To determine the incidence, and consequences of misinterpretation, of a CT artefact in a paediatric imaging department. A retrospective review of images and reports of paediatric CT scans over a set period with a known artefact was performed. Reports were correlated with reviewers' evaluation of the presence of artefact and reviewed for correct identification of artefact, misinterpretation as pathology, and action taken as a result. A total of 74 CT scans had been performed over the study period and an artefact detected by reviewers on 32 (43%). Six (18.75%) of these were misinterpreted as pathology, of which three (9.4%) were reported as tuberculous granulomas, two (6.2%) as haemorrhages and one (3.1%) as an unknown hyperdensity. Two patients (6.2%) had subsequent MRI studies performed, and treatment for tuberculosis was continued in one patient (3.1%). No initial report identified the artefact. One-fifth of the scans with the artefact were misinterpreted as pathology and half of these misinterpretations led to further action. Artefacts result in false diagnoses and unnecessary investigations; vigilance is needed. (orig.)

  4. Detection, visualization and evaluation of anomalous coronary anatomy on 16-slice multidetector-row CT

    NARCIS (Netherlands)

    van Ooijen, P.M.A.; Dorgelo, J.; Zijlstra, F.; Oudkerk, M.

    2004-01-01

    Early identification and evaluation of relatively frequent anomalous coronary anatomy is quite relevant because of the occurrence of sudden cardiac death or related symptoms of myocardial ischemia. Selective coronary angiography (CAG) is invasive, expensive and cannot always provide the required

  5. Accuracy of intermediate dose of furosemide injection to improve multidetector row CT urography

    International Nuclear Information System (INIS)

    Roy, Catherine; Jeantroux, Jeremy; Irani, Farah G.; Sauer, Benoit; Lang, Herve; Saussine, Christian

    2008-01-01

    Objective: Evaluate the usefulness of intermediate dose furosemide to improve visualization of the intrarenal collecting system and ureter using MDCTU. Materials and methods: Two groups of 100 patients without urinary tract disease or major abdominal pathology underwent MDCTU. Group I (various abdominal indications) was performed without any additional preparation and Group II (suspicion of urinary tract disease) 10 min after injection of furosemide (20 mg). MIP images of the excretory phase were post-processed. Maximal short-axis diameter of the pelvis and ureter were measured on axial images for all phases. Visualization of the collecting system wall and the identification of the whole ureter were assessed. Results: Mean pelvic diameter before contrast was (7.4 mm, S.D. ± 2.7; 13.4 mm, S.D. ± 4.1), on cortico-medullary phase (8.4 mm, S.D. ± 4.2; 14.3 mm, S.D. ± 4), on nephrographic phase (8.1 mm, S.D. ± 2.5; 14.8 mm, S.D. ± 4) and on excretory phase (9.7 mm, S.D. ± 3.4; 14.9 mm, S.D. ± 4.5), respectively, for Groups I and II. Intrarenal collecting system wall was clearly identified on both corticomedullary and nephrographic phases in 91% of Group II against 20% of Group I. Opacification of the entire ureter was excellent on excretory phase in 96% of Group II against 13% of Group I. The difference between the mean values for the two groups was statistically significant for all phases (p -9 ). Conclusion: Intermediate-dose furosemide (20 mg) before MDCTU is a very simple add-on for accurate depiction of pelvicalyceal details and collecting system wall without artefacts. The procedure is associated with a constant and complete visualisation of the entire urete

  6. Accuracy of intermediate dose of furosemide injection to improve multidetector row CT urography

    Energy Technology Data Exchange (ETDEWEB)

    Roy, Catherine [Department of Radiology B, Universitary Hospital of Strasbourg-Civil Hospital, 1, Place de l' hopital BP 426, 67091 Strasbourg Cedex (France)], E-mail: catherine.roy@chru-strasbourg.fr; Jeantroux, Jeremy; Irani, Farah G.; Sauer, Benoit [Department of Radiology B, Universitary Hospital of Strasbourg-Civil Hospital, 1, Place de l' hopital BP 426, 67091 Strasbourg Cedex (France); Lang, Herve; Saussine, Christian [Department of Urology, Universitary Hospital of Strasbourg-Civil Hospital, 1, Place de l' hopital BP 426, 67091 Strasbourg Cedex (France)

    2008-05-15

    Objective: Evaluate the usefulness of intermediate dose furosemide to improve visualization of the intrarenal collecting system and ureter using MDCTU. Materials and methods: Two groups of 100 patients without urinary tract disease or major abdominal pathology underwent MDCTU. Group I (various abdominal indications) was performed without any additional preparation and Group II (suspicion of urinary tract disease) 10 min after injection of furosemide (20 mg). MIP images of the excretory phase were post-processed. Maximal short-axis diameter of the pelvis and ureter were measured on axial images for all phases. Visualization of the collecting system wall and the identification of the whole ureter were assessed. Results: Mean pelvic diameter before contrast was (7.4 mm, S.D. {+-} 2.7; 13.4 mm, S.D. {+-} 4.1), on cortico-medullary phase (8.4 mm, S.D. {+-} 4.2; 14.3 mm, S.D. {+-} 4), on nephrographic phase (8.1 mm, S.D. {+-} 2.5; 14.8 mm, S.D. {+-} 4) and on excretory phase (9.7 mm, S.D. {+-} 3.4; 14.9 mm, S.D. {+-} 4.5), respectively, for Groups I and II. Intrarenal collecting system wall was clearly identified on both corticomedullary and nephrographic phases in 91% of Group II against 20% of Group I. Opacification of the entire ureter was excellent on excretory phase in 96% of Group II against 13% of Group I. The difference between the mean values for the two groups was statistically significant for all phases (p < 10{sup -9}). Conclusion: Intermediate-dose furosemide (20 mg) before MDCTU is a very simple add-on for accurate depiction of pelvicalyceal details and collecting system wall without artefacts. The procedure is associated with a constant and complete visualisation of the entire urete.

  7. Computational Modeling for Enhancing Soft Tissue Image Guided Surgery: An Application in Neurosurgery.

    Science.gov (United States)

    Miga, Michael I

    2016-01-01

    With the recent advances in computing, the opportunities to translate computational models to more integrated roles in patient treatment are expanding at an exciting rate. One area of considerable development has been directed towards correcting soft tissue deformation within image guided neurosurgery applications. This review captures the efforts that have been undertaken towards enhancing neuronavigation by the integration of soft tissue biomechanical models, imaging and sensing technologies, and algorithmic developments. In addition, the review speaks to the evolving role of modeling frameworks within surgery and concludes with some future directions beyond neurosurgical applications.

  8. Automatic individualized contrast medium dosage during hepatic computed tomography by using computed tomography dose index volume (CTDI{sub vol})

    Energy Technology Data Exchange (ETDEWEB)

    Svensson, Anders; Cederlund, Kerstin; Aspelin, Peter; Brismar, Torkel B. [Intervention and Technology at Karolinska Institutet, Department of Clinical Science, Division of Medical Imaging and Technology, Stockholm (Sweden); Karolinska University Hospital in Huddinge, Department of Radiology, Stockholm (Sweden); Bjoerk, Jonas [FoU-centrum Skaane Skaanes Universitetssjukhus i Lund, Lund (Sweden); Nyman, Ulf [University of Lund, Department of Diagnostic Radiology, Lasarettet Trelleborg, Trelleborg (Sweden)

    2014-08-15

    To compare hepatic parenchymal contrast media (CM) enhancement during multi-detector row computed tomography (MDCT) and its correlation with volume pitch-corrected computed tomography dose index (CTDI{sub vol}) and body weight (BW). One hundred patients referred for standard three-phase thoraco-abdominal MDCT examination were enrolled. BW was measured in the CT suite. Forty grams of iodine was administered intravenously (iodixanol 320 mg I/ml at 5 ml/s or iomeprol 400 mg I/ml at 4 ml/s) followed by a 50-ml saline flush. CTDI{sub vol} presented by the CT equipment during the parenchymal examination was recorded. The CM enhancement of the liver was defined as the attenuation HU of the liver parenchyma during the hepatic parenchymal phase minus the attenuation in the native phase. Liver parenchymal enhancement was negatively correlated to both CTDI{sub vol} (r = -0.60) and BW (r = -0.64), but the difference in correlation between those two was not significant. CTDI{sub vol} may replace BW when adjusting CM doses to body size. This makes it potentially feasible to automatically individualize CM dosage by CT. (orig.)

  9. Image calibration and registration in cone-beam computed tomogram for measuring the accuracy of computer-aided implant surgery

    Science.gov (United States)

    Lam, Walter Y. H.; Ngan, Henry Y. T.; Wat, Peter Y. P.; Luk, Henry W. K.; Goto, Tazuko K.; Pow, Edmond H. N.

    2015-02-01

    Medical radiography is the use of radiation to "see through" a human body without breaching its integrity (surface). With computed tomography (CT)/cone beam computed tomography (CBCT), three-dimensional (3D) imaging can be produced. These imagings not only facilitate disease diagnosis but also enable computer-aided surgical planning/navigation. In dentistry, the common method for transfer of the virtual surgical planning to the patient (reality) is the use of surgical stent either with a preloaded planning (static) like a channel or a real time surgical navigation (dynamic) after registration with fiducial markers (RF). This paper describes using the corner of a cube as a radiopaque fiducial marker on an acrylic (plastic) stent, this RF allows robust calibration and registration of Cartesian (x, y, z)- coordinates for linking up the patient (reality) and the imaging (virtuality) and hence the surgical planning can be transferred in either static or dynamic way. The accuracy of computer-aided implant surgery was measured with reference to coordinates. In our preliminary model surgery, a dental implant was planned virtually and placed with preloaded surgical guide. The deviation of the placed implant apex from the planning was x=+0.56mm [more right], y=- 0.05mm [deeper], z=-0.26mm [more lingual]) which was within clinically 2mm safety range. For comparison with the virtual planning, the physically placed implant was CT/CBCT scanned and errors may be introduced. The difference of the actual implant apex to the virtual apex was x=0.00mm, y=+0.21mm [shallower], z=-1.35mm [more lingual] and this should be brought in mind when interpret the results.

  10. Computer Simulation Surgery for Mandibular Reconstruction Using a Fibular Osteotomy Guide

    Directory of Open Access Journals (Sweden)

    Woo Shik Jeong

    2014-09-01

    Full Text Available In the present study, a fibular osteotomy guide based on a computer simulation was applied to a patient who had undergone mandibular segmental ostectomy due to oncological complications. This patient was a 68-year-old woman who presented to our department with a biopsy-proven squamous cell carcinoma on her left gingival area. This lesion had destroyed the cortical bony structure, and the patient showed attenuation of her soft tissue along the inferior alveolar nerve, indicating perineural spread of the tumor. Prior to surgery, a three-dimensional computed tomography scan of the facial and fibular bones was performed. We then created a virtual computer simulation of the mandibular segmental defect through which we segmented the fibular to reconstruct the proper angulation in the original mandible. Approximately 2-cm segments were created on the basis of this simulation and applied to the virtually simulated mandibular segmental defect. Thus, we obtained a virtual model of the ideal mandibular reconstruction for this patient with a fibular free flap. We could then use this computer simulation for the subsequent surgery and minimize the bony gaps between the multiple fibular bony segments.

  11. The growth of computer-assisted (robotic surgery in urology 2000–2014: The role of Asian surgeons

    Directory of Open Access Journals (Sweden)

    Deepansh Dalela

    2015-01-01

    Conclusion: The addition of robot to the surgical armamentarium has allowed better patient care and improved disease outcomes. VUI and surgeons of Asian origin have played a pioneering role in dissemination of computer-assisted surgery.

  12. Three-dimensional digitizer (neuronavigator): new equipment for computed tomography-guided stereotaxic surgery.

    Science.gov (United States)

    Watanabe, E; Watanabe, T; Manaka, S; Mayanagi, Y; Takakura, K

    1987-06-01

    A new device was invented as an adjunct for computed tomography (CT)-guided stereotaxic or open neurosurgery. It is composed of a multijoint three-dimensional digitizer (sensor arm) and a microcomputer, which indicates the place of the sensor arm tip on preoperative CT images. Computed tomography scan is performed preoperatively with three markers placed on the nasion and ears. At surgery, after fixing the patient's head and the sensor arm, sampling of the standard points was done to translate the position of the tip of the sensor arm onto the CT images displayed on a computer screen. In this way positional data from conventional preoperative CT scan can be directly transferred into the surgical field. This system has the unique feature of introducing CT-guided stereotaxis into conventional open neurosurgery.

  13. Syringohydromyelia following meningomyelocele surgery - role of metrizamide myelography and computed tomography

    International Nuclear Information System (INIS)

    Stanley, P.; Senac, M.O. Jr.; Segall, H.D.; Park, T.S.

    1984-01-01

    Five children developed symptoms attributable to syringohydromyelia several years following neonatal surgery for lumbosacral meningomyelocele. Metrizamide injection followed by computed tomography (CT) was performed in all five patients. In two patients, there was direct opacification of both the subarachnoid space and the syringohydromyelia. In a further two patients, delayed CT demonstrated late opacification of the central cavity from contrast introduced into the subarachnoid space. In the fifth patient via a suboccipital puncture, there was fortuitous filling of a caudally displaced fourth ventricle communicating with a central cavity within the cord, but there was no visualization of the subarachnoid space. Surgery with decompression and plugging of the obex halted the progression of the disease in all the patients. (orig.)

  14. Development of customized positioning guides using computer-aided design and manufacturing technology for orthognathic surgery.

    Science.gov (United States)

    Lin, Hsiu-Hsia; Chang, Hsin-Wen; Lo, Lun-Jou

    2015-12-01

    The purpose of this study was to devise a method for producing customized positioning guides for translating virtual plans to actual orthognathic surgery, and evaluation of the feasibility and validity of the devised method. Patients requiring two-jaw orthognathic surgery were enrolled and consented before operation. Two types of positioning guides were designed and fabricated using computer-aided design and manufacturing technology: One of the guides was used for the LeFort I osteotomy, and the other guide was used for positioning the maxillomandibular complex. The guides were fixed to the medial side of maxilla. For validation, the simulation images and postoperative cone beam computed tomography images were superimposed using surface registration to quantify the difference between the images. The data were presented in root-mean-square difference (RMSD) values. Both sets of guides were experienced to provide ideal fit and maximal contact to the maxillary surface to facilitate their accurate management in clinical applications. The validation results indicated that RMSD values between the images ranged from 0.18 to 0.33 mm in the maxilla and from 0.99 to 1.56 mm in the mandible. The patients were followed up for 6 months or more, and all of them were satisfied with the results. The proposed customized positioning guides are practical and reliable for translation of virtual plans to actual surgery. Furthermore, these guides improved the efficiency and outcome of surgery. This approach is uncomplicated in design, cost-effective in fabrication, and particularly convenient to use.

  15. Computer-assisted surgery: virtual- and augmented-reality displays for navigation during urological interventions.

    Science.gov (United States)

    van Oosterom, Matthias N; van der Poel, Henk G; Navab, Nassir; van de Velde, Cornelis J H; van Leeuwen, Fijs W B

    2018-03-01

    To provide an overview of the developments made for virtual- and augmented-reality navigation procedures in urological interventions/surgery. Navigation efforts have demonstrated potential in the field of urology by supporting guidance for various disorders. The navigation approaches differ between the individual indications, but seem interchangeable to a certain extent. An increasing number of pre- and intra-operative imaging modalities has been used to create detailed surgical roadmaps, namely: (cone-beam) computed tomography, MRI, ultrasound, and single-photon emission computed tomography. Registration of these surgical roadmaps with the real-life surgical view has occurred in different forms (e.g. electromagnetic, mechanical, vision, or near-infrared optical-based), whereby the combination of approaches was suggested to provide superior outcome. Soft-tissue deformations demand the use of confirmatory interventional (imaging) modalities. This has resulted in the introduction of new intraoperative modalities such as drop-in US, transurethral US, (drop-in) gamma probes and fluorescence cameras. These noninvasive modalities provide an alternative to invasive technologies that expose the patients to X-ray doses. Whereas some reports have indicated navigation setups provide equal or better results than conventional approaches, most trials have been performed in relatively small patient groups and clear follow-up data are missing. The reported computer-assisted surgery research concepts provide a glimpse in to the future application of navigation technologies in the field of urology.

  16. The current status and future prospects of computer-assisted hip surgery.

    Science.gov (United States)

    Inaba, Yutaka; Kobayashi, Naomi; Ike, Hiroyuki; Kubota, So; Saito, Tomoyuki

    2016-03-01

    The advances in computer assistance technology have allowed detailed three-dimensional preoperative planning and simulation of preoperative plans. The use of a navigation system as an intraoperative assistance tool allows more accurate execution of the preoperative plan, compared to manual operation without assistance of the navigation system. In total hip arthroplasty using CT-based navigation, three-dimensional preoperative planning with computer software allows the surgeon to determine the optimal angle of implant placement at which implant impingement is unlikely to occur in the range of hip joint motion necessary for daily activities of living, and to determine the amount of three-dimensional correction for leg length and offset. With the use of computer navigation for intraoperative assistance, the preoperative plan can be precisely executed. In hip osteotomy using CT-based navigation, the navigation allows three-dimensional preoperative planning, intraoperative confirmation of osteotomy sites, safe performance of osteotomy even under poor visual conditions, and a reduction in exposure doses from intraoperative fluoroscopy. Positions of the tips of chisels can be displayed on the computer monitor during surgery in real time, and staff other than the operator can also be aware of the progress of surgery. Thus, computer navigation also has an educational value. On the other hand, its limitations include the need for placement of trackers, increased radiation exposure from preoperative CT scans, and prolonged operative time. Moreover, because the position of a bone fragment cannot be traced after osteotomy, methods to find its precise position after its movement need to be developed. Despite the need to develop methods for the postoperative evaluation of accuracy for osteotomy, further application and development of these systems are expected in the future. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  17. Comparison of image features calculated in different dimensions for computer-aided diagnosis of lung nodules

    Science.gov (United States)

    Xu, Ye; Lee, Michael C.; Boroczky, Lilla; Cann, Aaron D.; Borczuk, Alain C.; Kawut, Steven M.; Powell, Charles A.

    2009-02-01

    Features calculated from different dimensions of images capture quantitative information of the lung nodules through one or multiple image slices. Previously published computer-aided diagnosis (CADx) systems have used either twodimensional (2D) or three-dimensional (3D) features, though there has been little systematic analysis of the relevance of the different dimensions and of the impact of combining different dimensions. The aim of this study is to determine the importance of combining features calculated in different dimensions. We have performed CADx experiments on 125 pulmonary nodules imaged using multi-detector row CT (MDCT). The CADx system computed 192 2D, 2.5D, and 3D image features of the lesions. Leave-one-out experiments were performed using five different combinations of features from different dimensions: 2D, 3D, 2.5D, 2D+3D, and 2D+3D+2.5D. The experiments were performed ten times for each group. Accuracy, sensitivity and specificity were used to evaluate the performance. Wilcoxon signed-rank tests were applied to compare the classification results from these five different combinations of features. Our results showed that 3D image features generate the best result compared with other combinations of features. This suggests one approach to potentially reducing the dimensionality of the CADx data space and the computational complexity of the system while maintaining diagnostic accuracy.

  18. What Can Computed Tomography Scans of the Thorax Show after Breast Surgery?

    Directory of Open Access Journals (Sweden)

    Afsaneh Alikhassi

    2016-06-01

    Full Text Available Background: Postoperative breast abnormalities after breast conserving surgery or modified radical mastectomy are frequently overlooked and inaccurately assessed or reported using multidetector computed tomography (MDCT. These inaccurate results may have legal ramifications for the clinicians, cause patients avoidable anxiety, and lead to additional unnecessary diagnostic follow-up testing and costs.Methods: The patients with a history of breast cancer who had undergone breast-conserving surgery or modified radical mastectomy up to 6 months prior to undergoing a thoracic MDCT scan consented and enrolled in this study. These patients underwent a thoracic MDCT scan either because of respiratory or cardiac clinical symptoms or as part of breast cancer staging.Results: Forty women were included in this study. Different postoperative breast changes observed on thoracic MDCT scans including fibrous scar tissue, fat necrosis, seroma, abscess, hematoma, and recurrent and residual tumor were described.Conclusions: MDCT scans offer sufficient evidence in many postoperative cases to allow a confident diagnosis. General radiologists who review thoracic MDCT scans should know how to characterize breast lesions incidentally found on MDCT scans after breast surgeries. This information would enhance the value of the radiologist’s report for appropriate case management.

  19. Effectiveness of revascularization surgery evaluated by proton magnetic resonance spectroscopy and single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Uno, Masaaki; Ueda, Shin; Hondo, Hideki; Matsumoto, Keizo; Harada, Masafumi [Tokushima Univ. (Japan). School of Medicine

    1996-08-01

    Proton magnetic resonance spectroscopy (MRS) and single photon emission computed tomography (SPECT) were used to evaluate chronic ischemic regions in 26 stroke patients before and 1, 3, and 6 months after revascularization surgery. The volume of interest for proton MRS was placed in an area including part of the frontal and temporal opercula, insular cortex, and basal ganglia. Twenty healthy volunteers served as controls for proton MRS. Patients were divided into three groups according to the preoperative proton MRS. Group A (n=12) had significantly lower N-acetylaspartate/choline (NAA/Cho) and N-acetylaspartate/creatine (NAA/Cr) ratios on the operative side compared to those on the contralateral side, and also lower than those in normal subjects. In seven patients in Group A, postoperative serial proton MRS demonstrated no recovery of these ratios on the operative side. However, proton MRS of the other five patients indicated gradual improvement in these ratios on the operative side at 3 to 6 months after surgery, and SPECT indicated an increase in cerebral blood flow on the operative side in four of these five patients. In Group B (n=9), proton MRS and SPECT showed no laterality before revascularization and no remarkable change during the postoperative course. In Group C (n=5), NAA/Cho or NAA/Cr decreased on the contralateral side preoperatively. Two patients showed fluctuating values of NAA/Cho or NAA/Cr during the postoperative period. Serial proton MRS and SPECT Studies may be useful for the evaluation of revascularization surgery on ischemic regions. The efficacy of revascularization surgery on the metabolism may appear gradually within 3-6 months. (author)

  20. Computed tomography assessment of lung structure in patients undergoing cardiac surgery with cardiopulmonary bypass

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, R.R.; Sawada, A.Y.; Fukuda, M.J.; Neves, F.H.; Carmona, M.J.; Auler, J.O.; Malbouisson, L.M.S., E-mail: malbouisson@hcnet.usp.b [Universidade de Sao Paulo (USP), SP (Brazil). Faculdade de Medicina. Hospital das Clinicas; Pelosi, P. [Universita' degli Studi dell' Insubria, Varese (Italy). Dipt. Ambiente, Salute e Sicurezza; Rouby, J.-J. [University Pierre and Marie Curie, Paris (France). La Pitie Salpetriere Hospital. Dept. of Anesthesiology and Critical Care and Medicine

    2011-06-15

    Hypoxemia is a frequent complication after coronary artery bypass graft (CABG) with cardiopulmonary bypass (CPB), usually attributed to atelectasis. Using computed tomography (CT), we investigated postoperative pulmonary alterations and their impact on blood oxygenation. Eighteen non-hypoxemic patients (15 men and 3 women) with normal cardiac function scheduled for CABG under CPB were studied. Hemodynamic measurements and blood samples were obtained before surgery, after intubation, after CPB, at admission to the intensive care unit, and 12, 24, and 48 h after surgery. Pre- and postoperative volumetric thoracic CT scans were acquired under apnea conditions after a spontaneous expiration. Data were analyzed by the paired Student t-test and one-way repeated measures analysis of variance. Mean age was 63 {+-} 9 years. The PaO{sub 2}/FiO{sub 2} ratio was significantly reduced after anesthesia induction, reaching its nadir after CPB and partially improving 12 h after surgery. Compared to preoperative CT, there was a 31% postoperative reduction in pulmonary gas volume (P < 0.001) while tissue volume increased by 19% (P < 0.001). Non-aerated lung increased by 253 {+-} 97 g (P < 0.001), from 3 to 27%, after surgery and poorly aerated lung by 72 {+-} 68 g (P < 0.001), from 24 to 27%, while normally aerated lung was reduced by 147 {+-} 119 g (P < 0.001), from 72 to 46%. No correlations (Pearson) were observed between PaO{sub 2}/FiO{sub 2} ratio or shunt fraction at 24 h postoperatively and postoperative lung alterations. The data show that lung structure is profoundly modified after CABG with CPB. Taken together, multiple changes occurring in the lungs contribute to postoperative hypoxemia rather than atelectasis alone. (author)

  1. Comparison of real and computer-simulated outcomes of LASIK refractive surgery

    Science.gov (United States)

    Cano, Daniel; Barbero, Sergio; Marcos, Susana

    2004-06-01

    Computer simulations of alternative LASIK ablation patterns were performed for corneal elevation maps of 13 real myopic corneas (range of myopia, -2.0 to -11.5 D). The computationally simulated ablation patterns were designed with biconic surfaces (standard Munnerlyn pattern, parabolic pattern, and biconic pattern) or with aberrometry measurements (customized pattern). Simulated results were compared with real postoperative outcomes. Standard LASIK refractive surgery for myopia increased corneal asphericity and spherical aberration. Computations with the theoretical Munnerlyn ablation pattern did not increase the corneal asphericity and spherical aberration. The theoretical parabolic pattern induced a slight increase of asphericity and spherical aberration, explaining only 40% of the clinically found increase. The theoretical biconic pattern controlled corneal spherical aberration. Computations showed that the theoretical customized pattern can correct high-order asymmetric aberrations. Simulations of changes in efficiency due to reflection and nonnormal incidence of the laser light showed a further increase in corneal asphericity. Consideration of these effects with a parabolic pattern accounts for 70% of the clinical increase in asphericity.

  2. Efficacy of navigation in skull base surgery using composite computer graphics of magnetic resonance and computed tomography images

    International Nuclear Information System (INIS)

    Hayashi, Nakamasa; Kurimoto, Masanori; Hirashima, Yutaka; Ikeda, Hiroaki; Shibata, Takashi; Tomita, Takahiro; Endo, Shunro

    2001-01-01

    The efficacy of a neurosurgical navigation system using three-dimensional composite computer graphics (CGs) of magnetic resonance (MR) and computed tomography (CT) images was evaluated in skull base surgery. Three-point transformation was used for integration of MR and CT images. MR and CT image data were obtained with three skin markers placed on the patient's scalp. Volume-rendering manipulations of the data produced three-dimensional CGs of the scalp, brain, and lesions from the MR images, and the scalp and skull from the CT. Composite CGs of the scalp, skull, brain, and lesion were created by registering the three markers on the three-dimensional rendered scalp images obtained from MR imaging and CT in the system. This system was used for 14 patients with skull base lesions. Three-point transformation using three-dimensional CGs was easily performed for multimodal registration. Simulation of surgical procedures on composite CGs aided in comprehension of the skull base anatomy and selection of the optimal approaches. Intraoperative navigation aided in determination of actual spatial position in the skull base and the optimal trajectory to the tumor during surgical procedures. (author)

  3. Novel imaging strategies for the detection of prosthetic heart valve obstruction and endocarditis

    NARCIS (Netherlands)

    W. Tanis (Wilco); R.P.J. Budde (Ricardo); I.A.C. van der Bilt (Ivo); B. Delemarre; G. Hoohenker; J.-K. Van Rooden; A.M. Scholtens (Asbjørn M.); J. Habets; S.A.J. Chamuleau (Steven)

    2016-01-01

    textabstractProsthetic heart valve (PHV) dysfunction remains difficult to recognise correctly by two-dimensional (2D) transthoracic and transoesophageal echocardiography (TTE/TEE). ECG-triggered multidetector-row computed tomography (MDCT), 18-fluorine-fluorodesoxyglucose positron emission

  4. Novel imaging strategies for the detection of prosthetic heart valve obstruction and endocarditis

    NARCIS (Netherlands)

    Tanis, W; Budde, R P J; van der Bilt, I A C; Delemarre, B; Hoohenkerk, G; van Rooden, J-K; Scholtens, A M; Habets, J; Chamuleau, S

    Prosthetic heart valve (PHV) dysfunction remains difficult to recognise correctly by two-dimensional (2D) transthoracic and transoesophageal echocardiography (TTE/TEE). ECG-triggered multidetector-row computed tomography (MDCT), 18-fluorine-fluorodesoxyglucose positron emission tomography including

  5. Comparison of the accuracy of cone beam computed tomography and medical computed tomography: implications for clinical diagnostics with guided surgery.

    Science.gov (United States)

    Abboud, Marcus; Calvo-Guirado, Jose Luis; Orentlicher, Gary; Wahl, Gerhard

    2013-01-01

    This study compared the accuracy of cone beam computed tomography (CBCT) and medical-grade CT in the context of evaluating the diagnostic value and accuracy of fiducial marker localization for reference marker-based guided surgery systems. Cadaver mandibles with attached radiopaque gutta-percha markers, as well as glass balls and composite cylinders of known dimensions, were measured manually with a highly accurate digital caliper. The objects were then scanned using a medical-grade CT scanner (Philips Brilliance 64) and five different CBCT scanners (Sirona Galileos, Morita 3D Accuitomo 80, Vatech PaX-Reve3D, 3M Imtech Iluma, and Planmeca ProMax 3D). The data were then imported into commercially available software, and measurements were made of the scanned markers and objects. CT and CBCT measurements were compared to each other and to the caliper measurements. The difference between the CBCT measurements and the caliper measurements was larger than the difference between the CT measurements and the caliper measurements. Measurements of the cadaver mandible and the geometric reference markers were highly accurate with CT. The average absolute errors of the human mandible measurements were 0.03 mm for CT and 0.23 mm for CBCT. The measurement errors of the geometric objects based on CT ranged between 0.00 and 0.12 mm, compared to an error range between 0.00 and 2.17 mm with the CBCT scanners. CT provided the most accurate images in this study, closely followed by one CBCT of the five tested. Although there were differences in the distance measurements of the hard tissue of the human mandible between CT and CBCT, these differences may not be of clinical significance for most diagnostic purposes. The fiducial marker localization error caused by some CBCT scanners may be a problem for guided surgery systems.

  6. Recent advances in 3D computed tomography techniques for simulation and navigation in hepatobiliary pancreatic surgery.

    Science.gov (United States)

    Uchida, Masafumi

    2014-04-01

    A few years ago it could take several hours to complete a 3D image using a 3D workstation. Thanks to advances in computer science, obtaining results of interest now requires only a few minutes. Many recent 3D workstations or multimedia computers are equipped with onboard 3D virtual patient modeling software, which enables patient-specific preoperative assessment and virtual planning, navigation, and tool positioning. Although medical 3D imaging can now be conducted using various modalities, including computed tomography (CT), magnetic resonance imaging (MRI), positron emission tomography (PET), and ultrasonography (US) among others, the highest quality images are obtained using CT data, and CT images are now the most commonly used source of data for 3D simulation and navigation image. If the 2D source image is bad, no amount of 3D image manipulation in software will provide a quality 3D image. In this exhibition, the recent advances in CT imaging technique and 3D visualization of the hepatobiliary and pancreatic abnormalities are featured, including scan and image reconstruction technique, contrast-enhanced techniques, new application of advanced CT scan techniques, and new virtual reality simulation and navigation imaging. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  7. Does computer-aided surgical simulation improve efficiency in bimaxillary orthognathic surgery?

    Science.gov (United States)

    Schwartz, H C

    2014-05-01

    The purpose of this study was to compare the efficiency of bimaxillary orthognathic surgery using computer-aided surgical simulation (CASS), with cases planned using traditional methods. Total doctor time was used to measure efficiency. While costs vary widely in different localities and in different health schemes, time is a valuable and limited resource everywhere. For this reason, total doctor time is a more useful measure of efficiency than is cost. Even though we use CASS primarily for planning more complex cases at the present time, this study showed an average saving of 60min for each case. In the context of a department that performs 200 bimaxillary cases each year, this would represent a saving of 25 days of doctor time, if applied to every case. It is concluded that CASS offers great potential for improving efficiency when used in the planning of bimaxillary orthognathic surgery. It saves significant doctor time that can be applied to additional surgical work. Copyright © 2013 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  8. Nasal and skull base anatomy of endoscopic endonasal transsphenoidal surgery with multi-detector computed tomography

    International Nuclear Information System (INIS)

    Hasegawa, Yuzo; Saeki, Naokatsu; Murai, Hisayuki; Horiguchi, Kentaro; Hanazawa, Toyoyuki; Okamoto, Miyoshi; Yanagawa, Noriyuki

    2008-01-01

    The endoscope is a new and highly useful instrument for transphenoidal surgery (TSS), and is generally used because of its minimally invasiveness. In addition, endoscopic transsphenoidal surgey (eTSS) has a potential for more radical tumor removal at the pituitary and the parasellar regions by wider visualization and more powerful illumination. To operate these regions safely, we need to know nasal and skull base anatomy under the endoscope which looks different from images under a microscope. In this paper, we demonstrated nasal and skull base anatomy with multi-detector computed tomography, which was performed in 23 recent patients with pituitary and parasellar legions. In the nasal legion, deviation of nasal septum and deviation of sphenoid ostium are important for endonasal approach of eTSS, and often determine the difficulty of surgery in the nasal cavity. Our study showed that deviation of nasal septum was seen in 26% of patients. Deviation of sphenoid ostium was 5.5±1.5 mm from the midline. The anatomy of sphenoid sinus plays a key role in our determination of the safety of a bony opening of the sella. In addition to sellar, presellar, and concha types, carotid prominence and optic prominence are important to determine the midline orientation. Development of carotid prominence was significantly related to the extent of lateral pneumatization of sphenoid sinus (P=0.0016). Reconstructed 3D-image of sphenoid sinus was very useful in visual understanding skull base anatomy. (author)

  9. Hemodynamic evaluation of vascular reconstructive surgery for childhood moyamoya disease using single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Takikawa, Shugo; Kamiyama, Hiroyasu; Abe, Hiroshi [Hokkaido Univ., Sapporo (Japan). School of Medicine; Mitsumori, Kenji; Tsuru, Mitsuo

    1990-06-01

    To evaluate the efficacy of vascular reconstructive surgery for childhood moyamoya disease, the cerebral blood flow (CBF) in 31 hemispheres of 16 patients was examined by single photon emission computed tomography (SPECT) using the {sup 133}Xe inhalation method. Results were divided into two groups; 17 hemispheres with superficial temporal artery-middle cerebral artery (STA-MCA) anastomosis (A(+) group) and 14 hemispheres without anastomosis (A(-) group). The mean hemispheric CBF (mCBF) and regional CBF (rCBF) in the frontal, temporal, occipital, and basal ganglia regions were calculated. Pre- and postoperative SPECT on the 10 hemispheres of the A(+) group showed an increase in mCBF in 6 hemispheres, the disappearance of the low perfusion area (LPA) in all 5 hemispheres where LPA was present before surgery, and an improvement in rCBF distribution (an increase in rCBF in the frontal and temporal lobes and a decrease in the basal ganglia). This suggests that vascular reconstruction is greatly effective in treating this disease. A comparison between the A(+) group and the A(-) group by postoperative SPECT, as well as the clinical outcomes and the postoperative findings of electroencephalography and angiography, revealed that the A(+) group was superior to the A(-) group in the frequency of LPA (12% and 43%, respectively) and rCBF in the frontal region where STA-MCA anastomosis was usually performed. These results indicate that STA-MCA anastomosis with indirect synangiosis is the most effective treatment of childhood moyamoya disease. (author).

  10. Inspiratory and expiratory computed tomographic volumetry for lung volume reduction surgery.

    Science.gov (United States)

    Morimura, Yuki; Chen, Fengshi; Sonobe, Makoto; Date, Hiroshi

    2013-06-01

    Three-dimensional (3D) computed tomographic (CT) volumetry has been introduced into the field of thoracic surgery, and a combination of inspiratory and expiratory 3D-CT volumetry provides useful data on regional pulmonary function as well as the volume of individual lung lobes. We report herein a case of a 62-year-old man with severe emphysema who had undergone lung volume reduction surgery (LVRS) to assess this technique as a tool for the evaluation of regional lung function and volume before and after LVRS. His postoperative pulmonary function was maintained in good condition despite a gradual slight decrease 2 years after LVRS. This trend was also confirmed by a combination of inspiratory and expiratory 3D-CT volumetry. We confirm that a combination of inspiratory and expiratory 3D-CT volumetry might be effective for the preoperative assessment of LVRS in order to determine the amount of lung tissue to be resected as well as for postoperative evaluation. This novel technique could, therefore, be used more widely to assess local lung function.

  11. Optimization of coronary attenuation in coronary computed tomography angiography using diluted contrast material.

    Science.gov (United States)

    Kawaguchi, Naoto; Kurata, Akira; Kido, Teruhito; Nishiyama, Yoshiko; Kido, Tomoyuki; Miyagawa, Masao; Ogimoto, Akiyoshi; Mochizuki, Teruhito

    2014-01-01

    The purpose of this study was to evaluate a personalized protocol with diluted contrast material (CM) for coronary computed tomography angiography (CTA). One hundred patients with suspected coronary artery disease underwent retrospective electrocardiogram-gated coronary CTA on a 256-slice multidetector-row CT scanner. In the diluted CM protocol (n=50), the optimal scan timing and CM dilution rate were determined by the timing bolus scan, with 20% CM dilution (5ml/s during 10s) being considered suitable to achieve the target arterial attenuation of 350 Hounsfield units (HU). In the body weight (BW)-adjusted protocol (n=50, 222mg iodine/kg), only the optimal scan timing was determined by the timing bolus scan. The injection rate and volume in the timing bolus scan and real scan were identical between the 2 protocols. We compared the means and variations in coronary attenuation between the 2 protocols. Coronary attenuation (mean±SD) in the diluted CM and BW-adjusted protocols was 346.1±23.9 HU and 298.8±45.2 HU, respectively. The diluted CM protocol provided significantly higher coronary attenuation and lower variance than did the BW-adjusted protocol (P<0.05, in each). The diluted CM protocol facilitates more uniform attenuation on coronary CTA in comparison with the BW-adjusted protocol.  

  12. Computer-assisted surgery for screw insertion into the distal sesamoid bone in horses: an in vitro study.

    Science.gov (United States)

    Gygax, Diego; Lischer, Christoph; Auer, Joerg A

    2006-10-01

    To compare the precision of computer-assisted surgery with a conventional technique (CV) using a special guiding device for screw insertion into the distal sesamoid bone in horses. In vitro experimental study. Cadaveric forelimb specimens. Insertion of a 3.5 mm cortex screw in lag fashion along the longitudinal axis of intact (non-fractured) distal sesamoid bones was evaluated in 2 groups (8 limbs each): CV and computer-assisted surgery (CAS). For CV, the screw was inserted using a special guiding device and fluoroscopy, whereas for CAS, the screw was inserted using computer-assisted navigation. The accuracy of screw placement was verified by radiography, computed tomography, and specimen dissection. Surgical precision was better in CAS compared with CV. CAS improves the accuracy of lateromedial screw insertion, in lag fashion, into the distal sesamoid bone. The CAS technique should be considered for improved accuracy of screw insertion in fractures of the distal sesamoid bone.

  13. Growing skin: A computational model for skin expansion in reconstructive surgery

    Science.gov (United States)

    Buganza Tepole, Adrián; Joseph Ploch, Christopher; Wong, Jonathan; Gosain, Arun K.; Kuhl, Ellen

    2011-10-01

    The goal of this manuscript is to establish a novel computational model for stretch-induced skin growth during tissue expansion. Tissue expansion is a common surgical procedure to grow extra skin for reconstructing birth defects, burn injuries, or cancerous breasts. To model skin growth within the framework of nonlinear continuum mechanics, we adopt the multiplicative decomposition of the deformation gradient into an elastic and a growth part. Within this concept, we characterize growth as an irreversible, stretch-driven, transversely isotropic process parameterized in terms of a single scalar-valued growth multiplier, the in-plane area growth. To discretize its evolution in time, we apply an unconditionally stable, implicit Euler backward scheme. To discretize it in space, we utilize the finite element method. For maximum algorithmic efficiency and optimal convergence, we suggest an inner Newton iteration to locally update the growth multiplier at each integration point. This iteration is embedded within an outer Newton iteration to globally update the deformation at each finite element node. To demonstrate the characteristic features of skin growth, we simulate the process of gradual tissue expander inflation. To visualize growth-induced residual stresses, we simulate a subsequent tissue expander deflation. In particular, we compare the spatio-temporal evolution of area growth, elastic strains, and residual stresses for four commonly available tissue expander geometries. We believe that predictive computational modeling can open new avenues in reconstructive surgery to rationalize and standardize clinical process parameters such as expander geometry, expander size, expander placement, and inflation timing.

  14. Ontology for assessment studies of human-computer-interaction in surgery.

    Science.gov (United States)

    Machno, Andrej; Jannin, Pierre; Dameron, Olivier; Korb, Werner; Scheuermann, Gerik; Meixensberger, Jürgen

    2015-02-01

    New technologies improve modern medicine, but may result in unwanted consequences. Some occur due to inadequate human-computer-interactions (HCI). To assess these consequences, an investigation model was developed to facilitate the planning, implementation and documentation of studies for HCI in surgery. The investigation model was formalized in Unified Modeling Language and implemented as an ontology. Four different top-level ontologies were compared: Object-Centered High-level Reference, Basic Formal Ontology, General Formal Ontology (GFO) and Descriptive Ontology for Linguistic and Cognitive Engineering, according to the three major requirements of the investigation model: the domain-specific view, the experimental scenario and the representation of fundamental relations. Furthermore, this article emphasizes the distinction of "information model" and "model of meaning" and shows the advantages of implementing the model in an ontology rather than in a database. The results of the comparison show that GFO fits the defined requirements adequately: the domain-specific view and the fundamental relations can be implemented directly, only the representation of the experimental scenario requires minor extensions. The other candidates require wide-ranging extensions, concerning at least one of the major implementation requirements. Therefore, the GFO was selected to realize an appropriate implementation of the developed investigation model. The ensuing development considered the concrete implementation of further model aspects and entities: sub-domains, space and time, processes, properties, relations and functions. The investigation model and its ontological implementation provide a modular guideline for study planning, implementation and documentation within the area of HCI research in surgery. This guideline helps to navigate through the whole study process in the form of a kind of standard or good clinical practice, based on the involved foundational frameworks

  15. Usefulness of follow-up computed tomography after surgery for early gastric cancer

    International Nuclear Information System (INIS)

    Ma, Hoon; Lee, Soon Jin; Kim, Soo Ah; Lim, Hyo Keun; No, Jae Hyung; Son, Tae Sung; Kim, Sung; Kim, Yong Il

    2002-01-01

    To analyze the recurrent rate, time of recurrence, type of recurrence and the relationship between recurrence and histopathologic findings after radical gastrectomy for early gastric cancer and evaluate the usefulness of follow up abdominal computed tomography after surgery. We retrospectively evaluated 617 abdominal computed tomographic examinations of 144 patients (101 male, 43 female, mean age, 53 years) who underwent radical subtotal gastrectomy for early gastric cancer between July 1994 and July 1997. Follow-up abdominal CT scans were reviewed by three abdominal radiologists for detection of recurrence of early gastric cancer, and endoscopic and pathologic findings were correlated. We also reviewed the surgical pathologic reports for location, size, cell type and depth of invasion of early gastric cancer and lymph node invasion. We analyzed the recurrent rate, time and type of recurrence, and relationship between recurrence rate and pathologic characteristics of early gastric cancer. The recurrent rate was 4.2% (6/144) during 5-7 years after radical subtotal gastrectomy for early gastric cancer. The recurrence was detected on 2-5 years after operation. The types of recurrence were lymph node metastasis (n=5), liver metastasis (n=4), recurrence in the residual stomach or anastomotic site (n=3), adrenal metastasis (n=1), and lung metastasis (n=1). Relationship between recurrence and location, size, depth of invasion and cell type of early gastric cancer and lymph node metastasis was non significant statistically (p>0.4). The recurrence rate of early gastric cancer after radical subtotal gastrectomy is very low and occurs after two years. The follow up-CT scans can detect all recurrence of early gastric cancer, so regular follow=up abdominal CT examination is useful

  16. Development of a computer-aided design software for dental splint in orthognathic surgery

    Science.gov (United States)

    Chen, Xiaojun; Li, Xing; Xu, Lu; Sun, Yi; Politis, Constantinus; Egger, Jan

    2016-12-01

    In the orthognathic surgery, dental splints are important and necessary to help the surgeon reposition the maxilla or mandible. However, the traditional methods of manual design of dental splints are difficult and time-consuming. The research on computer-aided design software for dental splints is rarely reported. Our purpose is to develop a novel special software named EasySplint to design the dental splints conveniently and efficiently. The design can be divided into two steps, which are the generation of initial splint base and the Boolean operation between it and the maxilla-mandibular model. The initial splint base is formed by ruled surfaces reconstructed using the manually picked points. Then, a method to accomplish Boolean operation based on the distance filed of two meshes is proposed. The interference elimination can be conducted on the basis of marching cubes algorithm and Boolean operation. The accuracy of the dental splint can be guaranteed since the original mesh is utilized to form the result surface. Using EasySplint, the dental splints can be designed in about 10 minutes and saved as a stereo lithography (STL) file for 3D printing in clinical applications. Three phantom experiments were conducted and the efficiency of our method was demonstrated.

  17. Three dimensional computed tomography lung modeling is useful in simulation and navigation of lung cancer surgery.

    Science.gov (United States)

    Ikeda, Norihiko; Yoshimura, Akinobu; Hagiwara, Masaru; Akata, Soichi; Saji, Hisashi

    2013-01-01

    The number of minimally invasive operations, such as video-assisted thoracoscopic surgery (VATS) lobectomy or segmentectomy, has enormously increased in recent years. These operations require extreme knowledge of the anatomy of pulmonary vessels and bronchi in each patient, and surgeons must carefully dissect the branches of pulmonary vessels during operation. Thus, foreknowledge of the anatomy of each patient would greatly contribute to the safety and accuracy of the operation. The development of multi-detector computed tomography (MDCT) has promoted three dimensional (3D) images of lung structures. It is possible to see the vascular and bronchial structures from the view of the operator; therefore, it is employed for preoperative simulation as well as navigation during operation. Due to advances in software, even small vessels can be accurately imaged, which is useful in performing segmentectomy. Surgical simulation and navigation systems based on high quality 3D lung modeling, including vascular and bronchial structures, can be used routinely to enhance the safety operation, education of junior staff, as well as providing a greater sense of security to the operators.

  18. Anatomic variants of interest in endoscopic sinus surgery: role of computed tomography

    International Nuclear Information System (INIS)

    Alonso, S.; Arenas, J.; Fernandez, F.; Gil, S.; Guirau, M. D.

    2000-01-01

    The detailed radiological study of the anatomy of the nasal cavities and paranasal sinus is essential prior to endoscopic sinus surgery since, on the one hand, it discloses the extent of the disease and, on the other hand, it aids in the detection of the numerous anatomic variants, some of which are of great interest to the endoscopic as the lack of preoperative knowledge of them may increase the risk of complications. the objective of the present report is to review these variants, stressing those that may be associated with a greater surgical risk. Although coronal computed tomography is the technique of choice for pre endoscopy examination, certain structures and anatomic variants are better viewed in axial images. These exceptions include anterior and posterior walls of the frontal sinuses, the anatomic relationships between posterior ethmoid complex and the sphenoid sinus, the relationships between the sphenoid sinus and the optic nerve, and the detection of Onodi cells. Thus, we recommend that the radiological examination include both coronal and axial images. (Author) 16 refs

  19. Establishment of computed tomography reference dose levels in Onassis Cardiac Surgery Center

    International Nuclear Information System (INIS)

    Tsapaki, V.; Kyrozi, E.; Syrigou, T.; Mastorakou, I.; Kottou, S.

    2001-01-01

    The purpose of the study was to apply European Commission (EC) Reference Dose Levels (RDL) in Computed Tomography (CT) examinations at Onassis Cardiac Surgery Center (OCSC). These are weighted CT Dose Index (CTDI w ) for a single slice and Dose-Length Product (DLP) for a complete examination. During the period 1998-1999, the total number of CT examinations, every type of CT examination, patient related data and technical parameters of the examinations were recorded. The most frequent examinations were chosen for investigation which were the head, chest, abdomen and pelvis. CTDI measurements were performed and CTDI w and DLP were calculated. Third Quartile values of CTDI w were chosen to be 43mGy for head, 8mGy for chest, and 22mGy for abdomen and pelvis examinations. Third quartile values of DLP were chosen to be 740mGycm for head, 370mGycm for chest, 490mGycm for abdomen and 420mGycm for pelvis examination. Results confirm that OCSC follows successfully the proposed RDL for the head, chest, abdomen and pelvis examinations in terms of radiation dose. (author)

  20. Investigation of the relative effects of vascular branching structure and gravity on pulmonary arterial blood flow heterogeneity via an image-based computational model.

    Science.gov (United States)

    Burrowes, Kelly S; Hunter, Peter J; Tawhai, Merryn H

    2005-11-01

    A computational model of blood flow through the human pulmonary arterial tree has been developed to investigate the relative influence of branching structure and gravity on blood flow distribution in the human lung. Geometric models of the largest arterial vessels and lobar boundaries were first derived using multidetector row x-ray computed tomography (MDCT) scans. Further accompanying arterial vessels were generated from the MDCT vessel endpoints into the lobar volumes using a volume-filling branching algorithm. Equations governing the conservation of mass and momentum were solved within the geometric model to calculate pressure, velocity, and vessel radius. Blood flow results in the anatomically based model, with and without gravity, and in a symmetric geometric model were compared to investigate their relative contributions to blood flow heterogeneity. Results showed a persistent blood flow gradient and flow heterogeneity in the absence of gravitational forces in the anatomically based model. Comparison with flow results in the symmetric model revealed that the asymmetric vascular branching structure was largely responsible for producing this heterogeneity. Analysis of average results in varying slice thicknesses illustrated a clear flow gradient because of gravity in "lower resolution" data (thicker slices), but on examination of higher resolution data, a trend was less obvious. Results suggest that although gravity does influence flow distribution, the influence of the tree branching structure is also a dominant factor. These results are consistent with high-resolution experimental studies that have demonstrated gravity to be only a minor determinant of blood flow distribution.

  1. Intraoperative computed tomography with an integrated navigation system in stabilization surgery for complex craniovertebral junction malformation.

    Science.gov (United States)

    Yu, Xinguang; Li, Lianfeng; Wang, Peng; Yin, Yiheng; Bu, Bo; Zhou, Dingbiao

    2014-07-01

    This study was designed to report our preliminary experience with stabilization procedures for complex craniovertebral junction malformation (CVJM) using intraoperative computed tomography (iCT) with an integrated neuronavigation system (NNS). To evaluate the workflow, feasibility and clinical outcome of stabilization procedures using iCT image-guided navigation for complex CVJM. The stabilization procedures in CVJM are complex because of the area's intricate geometry and bony structures, its critical relationship to neurovascular structures and the intricate biomechanical issues involved. A sliding gantry 40-slice computed tomography scanner was installed in a preexisting operating room. The images were transferred directly from the scanner to the NNS using an automated registration system. On the basis of the analysis of intraoperative computed tomographic images, 23 cases (11 males, 12 females) with complicated CVJM underwent navigated stabilization procedures to allow more control over screw placement. The age of these patients were 19-52 years (mean: 33.5 y). We performed C1-C2 transarticular screw fixation in 6 patients to produce atlantoaxial arthrodesis with better reliability. Because of a high-riding transverse foramen on at least 1 side of the C2 vertebra and an anomalous vertebral artery position, 7 patients underwent C1 lateral mass and C2 pedicle screw fixation. Ten additional patients were treated with individualized occipitocervical fixation surgery from the hypoplasia of C1 or constraints due to C2 bone structure. In total, 108 screws were inserted into 23 patients using navigational assistance. The screws comprised 20 C1 lateral mass screws, 26 C2, 14 C3, or 4 C4 pedicle screws, 32 occipital screws, and 12 C1-C2 transarticular screws. There were no vascular or neural complications except for pedicle perforations that were detected in 2 (1.9%) patients and were corrected intraoperatively without any persistent nerves or vessel damage. The overall

  2. Investigational Clinical Trial of a Prototype Optoelectronic Computer-Aided Navigation Device for Dental Implant Surgery.

    Science.gov (United States)

    Jokstad, Asbjørn; Winnett, Brenton; Fava, Joseph; Powell, David; Somogyi-Ganss, Eszter

    New digital technologies enable real-time computer-aided (CA) three-dimensional (3D) guidance during dental implant surgery. The aim of this investigational clinical trial was to demonstrate the safety and effectiveness of a prototype optoelectronic CA-navigation device in comparison with the conventional approach for planning and effecting dental implant surgery. Study participants with up to four missing teeth were recruited from the pool of patients referred to the University of Toronto Graduate Prosthodontics clinic. The first 10 participants were allocated to either a conventional or a prototype device study arm in a randomized trial. The next 10 participants received implants using the prototype device. All study participants were restored with fixed dental prostheses after 3 (mandible) or 6 (maxilla) months healing, and monitored over 12 months. The primary outcome was the incidence of any surgical, biologic, or prosthetic adverse events or device-related complications. Secondary outcomes were the incidence of positioning of implants not considered suitable for straightforward prosthetic restoration (yes/no); the perception of the ease of use of the prototype device by the two oral surgeons, recorded by use of a Likert-type questionnaire; and the clinical performance of the implant and superstructure after 1 year in function. Positioning of the implants was appraised on periapical radiographs and clinical photographs by four independent blinded examiners. Peri-implant bone loss was measured on periapical radiographs by a blinded examiner. No adverse events occurred related to placing any implants. Four device-related complications led to a switch from using the prototype device to the conventional method. All implants placed by use of the prototype device were in a position considered suitable for straightforward prosthetic restoration (n = 21). The qualitative evaluation by the surgeons was generally positive, although ergonomic challenges were identified

  3. Protocol for concomitant temporomandibular joint custom-fitted total joint reconstruction and orthognathic surgery utilizing computer-assisted surgical simulation.

    Science.gov (United States)

    Movahed, Reza; Teschke, Marcus; Wolford, Larry M

    2013-12-01

    Clinicians who address temporomandibular joint (TMJ) pathology and dentofacial deformities surgically can perform the surgery in 1 stage or 2 separate stages. The 2-stage approach requires the patient to undergo 2 separate operations and anesthesia, significantly prolonging the overall treatment. However, performing concomitant TMJ and orthognathic surgery (CTOS) in these cases requires careful treatment planning and surgical proficiency in the 2 surgical areas. This article presents a new treatment protocol for the application of computer-assisted surgical simulation in CTOS cases requiring reconstruction with patient-fitted total joint prostheses. The traditional and new CTOS protocols are described and compared. The new CTOS protocol helps decrease the preoperative workup time and increase the accuracy of model surgery. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  4. The benefit of non contrast-enhanced magnetic resonance angiography for predicting vascular access surgery outcome: a computer model perspective.

    Directory of Open Access Journals (Sweden)

    Maarten A G Merkx

    Full Text Available INTRODUCTION: Vascular access (VA surgery, a prerequisite for hemodialysis treatment of end-stage renal-disease (ESRD patients, is hampered by complication rates, which are frequently related to flow enhancement. To assist in VA surgery planning, a patient-specific computer model for postoperative flow enhancement was developed. The purpose of this study is to assess the benefit of non contrast-enhanced magnetic resonance angiography (NCE-MRA data as patient-specific geometrical input for the model-based prediction of surgery outcome. METHODS: 25 ESRD patients were included in this study. All patients received a NCE-MRA examination of the upper extremity blood vessels in addition to routine ultrasound (US. Local arterial radii were assessed from NCE-MRA and converted to model input using a linear fit per artery. Venous radii were determined with US. The effect of radius measurement uncertainty on model predictions was accounted for by performing Monte-Carlo simulations. The resulting flow prediction interval of the computer model was compared with the postoperative flow obtained from US. Patients with no overlap between model-based prediction and postoperative measurement were further analyzed to determine whether an increase in geometrical detail improved computer model prediction. RESULTS: Overlap between postoperative flows and model-based predictions was obtained for 71% of patients. Detailed inspection of non-overlapping cases revealed that the geometrical details that could be assessed from NCE-MRA explained most of the differences, and moreover, upon addition of these details in the computer model the flow predictions improved. CONCLUSIONS: The results demonstrate clearly that NCE-MRA does provide valuable geometrical information for VA surgery planning. Therefore, it is recommended to use this modality, at least for patients at risk for local or global narrowing of the blood vessels as well as for patients for whom an US-based model

  5. Loss of cellular viability in areas of ground-glass opacity on computed tomography images immediately after pulmonary radiofrequency ablation in rabbits

    International Nuclear Information System (INIS)

    Kuroki, Masaomi; Nakada, Hiroshi; Yamashita, Atsushi; Sawaguchi, Akira; Uchino, Noriko; Sato, Shinya; Asada, Yujiro; Tamura, Shozo; Asanuma, Taketoshi

    2012-01-01

    The purpose of this study was to determine cellular viability of lung parenchyma and neoplastic cells in areas of ground-glass opacity (GGO) on computed tomography (CT) images immediately after pulmonary radiofrequency ablation (RFA) in rabbits. A LeVeen RFA electrode was placed percutaneously into rabbit lungs with or without metastatic VX2 tumors. Five minutes later, seven isolated lungs were imaged by use of a multi-detector row CT scanner, and the images were compared with histological features. The cellular viability of the lung tissues was assessed by nicotinamide adenine dinucleotide hydrogen (NADH) staining in eight normal lungs and in three lungs with multiple metastatic tumors. All lung lesions appeared as bilayered structures with a central, dense, attenuated area and an outer area of GGO on CT images, and as three-layered structures on macroscopic and microscopic images 5 min after RFA. The GGO areas approximately corresponded to the outer two layers in macroscopic images that were exudative and congestive on microscopic images. Staining for NADH was significantly reduced in the GGO and densely attenuated areas with or without tumor tissue staining compared with the non-ablated area. Our results suggest that an area of GGO that appears on CT immediately after RFA can be effectively treated by RFA. (author)

  6. Use of computer-assisted design and manufacturing to localize dural venous sinuses during reconstructive surgery for craniosynostosis.

    Science.gov (United States)

    Iyer, Rajiv R; Wu, Adela; Macmillan, Alexandra; Musavi, Leila; Cho, Regina; Lopez, Joseph; Jallo, George I; Dorafshar, Amir H; Ahn, Edward S

    2018-01-01

    Cranial vault remodeling surgery for craniosynostosis carries the potential risk of dural venous sinus injury given the extensive bony exposure. Identification of the dural venous sinuses can be challenging in patients with craniosynostosis given the lack of accurate surface-localizing landmarks. Computer-aided design and manufacturing (CAD/CAM) has allowed surgeons to pre-operatively plan these complex procedures in an effort to increase reconstructive efficiency. An added benefit of this technology is the ability to intraoperatively map the dural venous sinuses based on pre-operative imaging. We utilized CAD/CAM technology to intraoperatively map the dural venous sinuses for patients undergoing reconstructive surgery for craniosynostosis in an effort to prevent sinus injury, increase operative efficiency, and enhance patient safety. Here, we describe our experience utilizing this intraoperative technology in pediatric patients with craniosynostosis. We retrospectively reviewed the charts of children undergoing reconstructive surgery for craniosynostosis using CAD/CAM surgical planning guides at our institution between 2012 and 2016. Data collected included the following: age, gender, type of craniosynostosis, estimated blood loss, sagittal sinus deviation from the sagittal suture, peri-operative outcomes, and hospital length of stay. Thirty-two patients underwent reconstructive cranial surgery for craniosynostosis, with a median age of 11 months (range, 7-160). Types of synostosis included metopic (6), unicoronal (6), sagittal (15), lambdoid (1), and multiple suture (4). Sagittal sinus deviation from the sagittal suture was maximal in unicoronal synostosis patients (10.2 ± 0.9 mm). All patients tolerated surgery well, and there were no occurrences of sagittal sinus, transverse sinus, or torcular injury. The use of CAD/CAM technology allows for accurate intraoperative dural venous sinus localization during reconstructive surgery for craniosynostosis and

  7. Computer-assisted surgery in orthopedic oncology : Technique, indications, and a descriptive study of 130 cases

    NARCIS (Netherlands)

    Gerbers, Jasper G.; Stevens, Martin; Ploegmakers, Joris J. W.; Bulstra, Sjoerd K.; Jutte, Paul C.

    2014-01-01

    Background and purpose - In orthopedic oncology, computerassisted surgery (CAS) can be considered an alternative to fluoroscopy and direct measurement for orientation, planning, and margin control. However, only small case series reporting specific applications have been published. We therefore

  8. [Three-dimensional evaluation of condylar morphology remodeling after orthognathic surgery in mandibular retrognathism by cone-beam computed tomography].

    Science.gov (United States)

    Chen, Shuo; Liu, Xiao-jing; Li, Zi-li; Liang, Cheng; Wang, Xiao-xia; Fu, Kai-yuan; Yi, Biao

    2015-08-18

    To evaluate the effect of orthognathic surgery on condylar morphology changes by comparing three-dimension surface reconstructions of condyles using cone-beam computed tomography (CBCT) data. In the study, 18 patients with mandible retrognathism deformities were included and CBCT data of 36 temporomandibular joints were collected before surgery and 12 months after surgery. Condyles were reconstructed and superimposed pre- and post-operatively to compare the changes of condylar surfaces. One-sample t test and χ2 test were performed for the analysis of three-dimension metric measurement and condylar head remodeling signs. P<0.05 was considered significant. The root-mean-square (RMS) of condylar surface changes before and after the surgery was (0.37±0.11) mm, which was significant statistically (P<0.05). The distribution of condylar remodeling signs showed significant difference (P<0.05). Bone resorption occurred predominantly in the posterior area of condylar head and bone formation occurred mainly in the anterior area. Three-dimension superimposition method based on CBCT data showed that condylar morphology had undergone remodeling after mandibular advancement.

  9. Computer-assisted preoperative simulation for positioning and fixation of plate in 2-stage procedure combining maxillary advancement by distraction technique and mandibular setback surgery

    Directory of Open Access Journals (Sweden)

    Hideyuki Suenaga

    2016-01-01

    Conclusion: The implementation of the computer-assisted preoperative simulation for the positioning and fixation of plate in 2-stage orthognathic procedure using distraction technique and mandibular setback surgery yielded good results.

  10. The role of 3-D imaging and computer-based postprocessing for surgery of the liver and pancreas

    International Nuclear Information System (INIS)

    Grenacher, L.; Kauffmann, G.W.; Richter, G.M.; Thorn, M.; Vetter, M.; Hassenpflug, P.; Meinzer, H.P.; Knaebel, H.P.; Kraus, T.; Buechler, M.W.

    2005-01-01

    Cross-sectional imaging based on navigation and virtual reality planning tools are well-established in the surgical routine in orthopedic surgery and neurosurgery. In various procedures, they have achieved a significant clinical relevance and efficacy and have enhanced the discipline's resection capabilities. In abdominal surgery, however, these tools have gained little attraction so far. Even with the advantage of fast and high resolution cross-sectional liver and pancreas imaging, it remains unclear whether 3D planning and interactive planning tools might increase precision and safety of liver and pancreas surgery. The inability to simply transfer the methodology from orthopedic or neurosurgery is mainly a result of intraoperative organ movements and shifting and corresponding technical difficulties in the on-line applicability of presurgical cross sectional imaging data. For the interactive planning of liver surgery, three systems partly exist in daily routine: HepaVision2 (MeVis GmbH, Bremen), LiverLive (Navidez Ltd. Slovenia) and OrgaNicer (German Cancer Research Center, Heidelberg). All these systems have realized a half- or full-automatic liver-segmentation procedure to visualize liver segments, vessel trees, resected volumes or critical residual organ volumes, either for preoperative planning or intraoperative visualization. Acquisition of data is mainly based on computed tomography. Three-dimensional navigation for intraoperative surgical guidance with ultrasound is part of the clinical testing. There are only few reports about the transfer of the visualization of the pancreas, probably caused by the difficulties with the segmentation routine due to inflammation or organ-exceeding tumor growth. With this paper, we like to evaluate and demonstrate the present status of software planning tools and pathways for future pre- and intraoperative resection planning in liver and pancreas surgery. (orig.)

  11. Intra-individual comparison of patient acceptability of multidetector-row CT colonography and double-contrast barium enema

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, S.A. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom)]. E-mail: csytaylor@yahoo.co.uk; Halligan, S. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom); Burling, D. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom); Bassett, P. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom); Bartram, C.I. [Department of Intestinal Imaging, St Mark' s and Northwick Park Hospitals, London (United Kingdom)

    2005-02-01

    AIMS: To compare the subjective acceptability of CT colonography in comparison with barium enema in older symptomatic patients, and to ascertain preferences for future colonic investigation. MATERIALS AND METHODS: The study population comprised 78 persons aged 60 years or over with symptoms suggestive of colorectal neoplasia, who underwent CT colonography followed the same day by barium enema. A 25-point questionnaire was administered after each procedure and an additional follow-up questionnaire a week later. Responses were compared using Wilcoxon matched pairs testing, Mann-Whitney test statistics and binomial exact testing. RESULTS: Participants suffered less physical discomfort during CT colonography (p=0.03) and overall satisfaction was greater compared with barium enema (p=0.03). On follow-up, respondents reported significantly better tolerance of CT colonography (p=0.002), and were less prepared to undergo barium enema again (p<0.001). Of 52 subjects expressing an opinion, all preferred CT to barium enema. CONCLUSION: Patient satisfaction was higher with CT colonography than barium enema. CT colonography caused significantly less physical discomfort and was overwhelmingly preferred by patients.

  12. Visualization of neonatal coronary arteries on multidetector row CT: ECG-gated versus non-ECG-gated technique

    International Nuclear Information System (INIS)

    Tsai, I.C.; Lee, Tain; Chen, Min-Chi; Fu, Yun-Ching; Jan, Sheng-Lin; Wang, Chung-Chi; Chang, Yen

    2007-01-01

    Multidetector CT (MDCT) seems to be a promising tool for detection of neonatal coronary arteries, but whether the ECG-gated or non-ECG-gated technique should be used has not been established. To compare the detection rate and image quality of neonatal coronary arteries on MDCT using ECG-gated and non-ECG-gated techniques. Twelve neonates with complex congenital heart disease were included. The CT scan was acquired using an ECG-gated technique, and the most quiescent phase of the RR interval was selected to represent the ECG-gated images. The raw data were then reconstructed without the ECG signal to obtain non-ECG-gated images. The detection rate and image quality of nine coronary artery segments in the two sets of images were then compared. A two-tailed paired t test was used with P values <0.05 considered as statistically significant. In all coronary segments the ECG-gated technique had a better detection rate and produced images of better quality. The difference between the two techniques ranged from 25% in the left main coronary artery to 100% in the distal right coronary artery. For neonates referred for MDCT, if evaluation of coronary artery anatomy is important for the clinical management or surgical planning, the ECG-gated technique should be used because it can reliably detect the coronary arteries. (orig.)

  13. Evaluation of thoracic abnormalities on 64-row multi-detector row CT: Comparison between axial images versus coronal reformations

    Energy Technology Data Exchange (ETDEWEB)

    Nishino, Mizuki [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215 (United States)]. E-mail: mnishino@bidmc.harvard.edu; Kubo, Takeshi [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215 (United States); Kataoka, Milliam L. [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215 (United States); Gautam, Shiva [Department of General Clinical Research Center and Biometrics, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215 (United States); Raptopoulos, Vassilios [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215 (United States); Hatabu, Hiroto [Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215 (United States)

    2006-07-15

    Purpose: To evaluate the capability of coronal reformations of chest on 64-row MDCT in demonstrating thoracic abnormalities in comparison with axial images. Materials and methods: Thirty-eight consecutive patients who underwent pulmonary CTA on 64-row MDCT were retrospectively studied with institutional review board (IRB) approval. Contiguous 2 mm axial and coronal images were reviewed independently with a 1-week interval, by consensus reading of two board-certified radiologists. Overall image quality was graded using a five-point scale. Abnormalities in mediastinum, hilum, pulmonary vessels, aorta, heart, esophagus, pleura, chest wall, and lung parenchyma were scored: 1 = definitely absent, 2 = probably absent, 3 = equivocal, 4 probably present, 5 = definitely present. Scores on axial and coronal images were compared using weighted {kappa} analysis. Results: Overall image quality was not different with statistical relevance between axial and coronal images (mean/median scores; 3.7/4; 3.6/4, respectively, P = 0.286, Wilcoxon signed-rank test). Significant agreement was observed between axial and coronal scores (mean weighted {kappa}, 0.661; range, 0.362-1). Agreement was almost perfect for pneumothorax, lung and pleural mass, effusion and consolidation (weighted {kappa} = 0.833-1); substantial for pulmonary embolism, trachea, mediastinal lymphadenopathy and non-skeletal chest wall lesion, heart, esophagus, and emphysema (weighted {kappa}, 0.618-0.799); moderate for atelectasis, mediastinum, hilar nodes, aorta, other lung lesions, skeletal chest wall lesions, linear scarring, nodules >1 cm, pulmonary artery abnormalities and pleural thickening (weighted {kappa}, 0.405-0.592); and fair for nodules <1 cm (weighted {kappa} = 0.362). Conclusion: Coronal reformations on 64-row MDCT had substantial agreement with axial images for evaluation of the majority of thoracic abnormalities.

  14. The emerging role of multidetector row CT angiography in the diagnosis of cervical arterial dissection: preliminary study

    International Nuclear Information System (INIS)

    Elijovich, Lucas; Kazmi, Khuram; Gauvrit, Jean Y.; Law, Meng

    2006-01-01

    Cervical artery dissection is an important cause of ischemic stroke, particularly in young patients. The diagnosis can be made with invasive catheter angiography or non-invasive imaging, either with MRI in conjunction with MR angiography (MRA) or CT angiography (CTA). Both modalities have been shown to have a high specificity and sensitivity. New developments such as multi-slice CTA (MSCTA) are emerging as an alternative methods for imaging the cervical and intracranial arteries. However, the contribution of modern MSCTA to carotid artery dissection has not been reported. We present a retrospective series of seven patients in whom both MSCTA and cervical axial T1 MRI and MRA were performed in the acute to subacute setting of internal carotid artery dissection. Carotid artery dissection was identified in all seven patients by MSCTA. The combination of MRI and MRA identified dissection in five of the seven patients. Additionally, a pseudoaneurysm was identified by MSCTA that was missed by MRI and MRA. Our findings confirm that MSCTA is a complementary technique in comparison to cervical axial T1 MRI and cervical MRA for diagnosing carotid artery dissection, and at times may provide additional information that can impact patient management. (orig.)

  15. Estudio vascular renal por TC multidetector de 64 canales 64-Multidetector row CT for the Renal Vascular Study

    OpenAIRE

    Daniela Stoisa; Fabrizzio E. Galiano; Andrés Quaranta; Roberto L. Villavicencio

    2009-01-01

    Objetivo: Mostrar las diversas variantes anatómicas vasculares tanto arteriales como venosas en el estudio angiográfico renal por tomografìa computada multidetector (TCMD) de 64 canales, dada su implicancia en un eventual planeamiento quirúrgico. Material y métodos: Evaluamos retrospectivamente 26 estudios realizados con tomógrafo Philips Brilliance de 64 canales. Se obtuvieron secuencias sin contraste y postcontraste e.v. en fases arterial y venosa, administrado con bomba inyectora doble cab...

  16. Intra-individual comparison of patient acceptability of multidetector-row CT colonography and double-contrast barium enema

    International Nuclear Information System (INIS)

    Taylor, S.A.; Halligan, S.; Burling, D.; Bassett, P.; Bartram, C.I.

    2005-01-01

    AIMS: To compare the subjective acceptability of CT colonography in comparison with barium enema in older symptomatic patients, and to ascertain preferences for future colonic investigation. MATERIALS AND METHODS: The study population comprised 78 persons aged 60 years or over with symptoms suggestive of colorectal neoplasia, who underwent CT colonography followed the same day by barium enema. A 25-point questionnaire was administered after each procedure and an additional follow-up questionnaire a week later. Responses were compared using Wilcoxon matched pairs testing, Mann-Whitney test statistics and binomial exact testing. RESULTS: Participants suffered less physical discomfort during CT colonography (p=0.03) and overall satisfaction was greater compared with barium enema (p=0.03). On follow-up, respondents reported significantly better tolerance of CT colonography (p=0.002), and were less prepared to undergo barium enema again (p<0.001). Of 52 subjects expressing an opinion, all preferred CT to barium enema. CONCLUSION: Patient satisfaction was higher with CT colonography than barium enema. CT colonography caused significantly less physical discomfort and was overwhelmingly preferred by patients

  17. Evaluation of thoracic abnormalities on 64-row multi-detector row CT: Comparison between axial images versus coronal reformations

    International Nuclear Information System (INIS)

    Nishino, Mizuki; Kubo, Takeshi; Kataoka, Milliam L.; Gautam, Shiva; Raptopoulos, Vassilios; Hatabu, Hiroto

    2006-01-01

    Purpose: To evaluate the capability of coronal reformations of chest on 64-row MDCT in demonstrating thoracic abnormalities in comparison with axial images. Materials and methods: Thirty-eight consecutive patients who underwent pulmonary CTA on 64-row MDCT were retrospectively studied with institutional review board (IRB) approval. Contiguous 2 mm axial and coronal images were reviewed independently with a 1-week interval, by consensus reading of two board-certified radiologists. Overall image quality was graded using a five-point scale. Abnormalities in mediastinum, hilum, pulmonary vessels, aorta, heart, esophagus, pleura, chest wall, and lung parenchyma were scored: 1 = definitely absent, 2 = probably absent, 3 = equivocal, 4 probably present, 5 = definitely present. Scores on axial and coronal images were compared using weighted κ analysis. Results: Overall image quality was not different with statistical relevance between axial and coronal images (mean/median scores; 3.7/4; 3.6/4, respectively, P = 0.286, Wilcoxon signed-rank test). Significant agreement was observed between axial and coronal scores (mean weighted κ, 0.661; range, 0.362-1). Agreement was almost perfect for pneumothorax, lung and pleural mass, effusion and consolidation (weighted κ = 0.833-1); substantial for pulmonary embolism, trachea, mediastinal lymphadenopathy and non-skeletal chest wall lesion, heart, esophagus, and emphysema (weighted κ, 0.618-0.799); moderate for atelectasis, mediastinum, hilar nodes, aorta, other lung lesions, skeletal chest wall lesions, linear scarring, nodules >1 cm, pulmonary artery abnormalities and pleural thickening (weighted κ, 0.405-0.592); and fair for nodules <1 cm (weighted κ = 0.362). Conclusion: Coronal reformations on 64-row MDCT had substantial agreement with axial images for evaluation of the majority of thoracic abnormalities

  18. Computing Cost Price for Cataract Surgery by Activity Based Costing (ABC Method at Hazrat-E-Zahra Hospital, Isfahan University of Medical Sciences, 2014

    Directory of Open Access Journals (Sweden)

    Masuod Ferdosi

    2016-10-01

    Full Text Available Background: Hospital managers need to have accurate information about actual costs to make efficient and effective decisions. In activity based costing method, first, activities are recognized and then direct and indirect costs are computed based on allocation methods. The aim of this study was to compute the cost price for cataract surgery by Activity Based Costing (ABC method at Hazrat-e-Zahra Hospital, Isfahan University of Medical Sciences. Methods: This was a cross- sectional study for computing the costs of cataract surgery by activity based costing technique in Hazrat-e-Zahra Hospital in Isfahan University of Medical Sciences, 2014. Data were collected through interview and direct observation and analyzed by Excel software. Results: According to the results of this study, total cost in cataract surgery was 8,368,978 Rials. Personnel cost included 62.2% (5,213,574 Rials of total cost of cataract surgery that is the highest share of surgery costs. The cost of consumables was 7.57% (1,992,852 Rials of surgery costs. Conclusion: Based on the results, there was different between cost price of the services and public Tariff which appears as hazards or financial crises to the hospital. Therefore, it is recommended to use the right methods to compute the costs relating to Activity Based Costing. Cost price of cataract surgery can be reduced by strategies such as decreasing the cost of consumables.

  19. Application of advanced virtual reality and 3D computer assisted technologies in tele-3D-computer assisted surgery in rhinology.

    Science.gov (United States)

    Klapan, Ivica; Vranjes, Zeljko; Prgomet, Drago; Lukinović, Juraj

    2008-03-01

    The real-time requirement means that the simulation should be able to follow the actions of the user that may be moving in the virtual environment. The computer system should also store in its memory a three-dimensional (3D) model of the virtual environment. In that case a real-time virtual reality system will update the 3D graphic visualization as the user moves, so that up-to-date visualization is always shown on the computer screen. Upon completion of the tele-operation, the surgeon compares the preoperative and postoperative images and models of the operative field, and studies video records of the procedure itself Using intraoperative records, animated images of the real tele-procedure performed can be designed. Virtual surgery offers the possibility of preoperative planning in rhinology. The intraoperative use of computer in real time requires development of appropriate hardware and software to connect medical instrumentarium with the computer and to operate the computer by thus connected instrumentarium and sophisticated multimedia interfaces.

  20. Computed Tomography-Assisted Thoracoscopic Surgery: A Novel, Innovative Approach in Patients With Deep Intrapulmonary Lesions of Unknown Malignant Status.

    Science.gov (United States)

    Kostrzewa, Michael; Kara, Kerim; Rathmann, Nils; Tsagogiorgas, Charalambos; Henzler, Thomas; Schoenberg, Stefan O; Hohenberger, Peter; Diehl, Steffen J; Roessner, Eric D

    2017-06-01

    Minimally invasive resection of small, deep intrapulmonary lesions can be challenging due to the difficulty of localizing them during video-assisted thoracoscopic surgery (VATS). We report our preliminary results evaluating the feasibility of an image-guided, minimally invasive, 1-stop-shop approach for the resection of small, deep intrapulmonary lesions in a hybrid operating room (OR). Fifteen patients (5 men, 10 women; mean age, 63 years) with a total of 16 solitary, deep intrapulmonary nodules of unknown malignant status were identified for intraoperative wire marking. Patients were placed on the operating table for resection by VATS. A marking wire was placed within the lesion under 3D laser and fluoroscopic guidance using a cone beam computed tomography system. Then, wedge resection by VATS was performed in the same setting without repositioning the patient. Complete resection with adequate safety margins was confirmed for all lesions. Marking wire placement facilitated resection in 15 of 16 lesions. Eleven lesions proved to be malignant, either primary or secondary; 5 were benign. Mean lesion size was 7.7 mm; mean distance to the pleural surface was 15.1 mm (mean lesion depth-diameter ratio, 2.2). Mean procedural time for marking wire placement was 35 minutes; mean VATS duration was 36 minutes. Computed tomography-assisted thoracoscopic surgery is a new, safe, and effective procedure for minimally invasive resection of small, deeply localized intrapulmonary lesions. The benefits of computed tomography-assisted thoracoscopic surgery are 1. One-stop-shop procedure, 2. Lower risk for the patient (no patient relocation, no marking wire loss), and 3. No need to coordinate scheduling between the CT room and OR.

  1. Computer-based decision making in medicine : A model for surgery of colorectal liver metastases

    NARCIS (Netherlands)

    Langenhoff, B S; Krabbe, P F M; Ruers, T J M

    2007-01-01

    AIMS: Seeking the best available treatment for patients with colorectal liver metastases may be complex due to the interpretation of many variables. In this study conjoint analysis is used to develop a decision model to help clinicians selecting patients eligible for surgery of liver metastases.

  2. Computer-aided design and computer-aided modeling (CAD/CAM) generated surgical splints, cutting guides and custom-made implants: Which indications in orthognathic surgery?

    Science.gov (United States)

    Scolozzi, P

    2015-12-01

    The purpose of the present report was to describe our indications, results and complications of computer-aided design and computer-aided modeling CAD/CAM surgical splints, cutting guides and custom-made implants in orthognathic surgery. We analyzed the clinical and radiological data of ten consecutive patients with dentofacial deformities treated using a CAD/CAM technique. Four patients had surgical splints and cutting guides for correction of maxillomandibular asymmetries, three had surgical cutting guides and customized internal distractors for correction of severe maxillary deficiencies and three had custom-made implants for additional chin contouring and/or mandibular defects following bimaxillary osteotomies and sliding genioplasty. We recorded age, gender, dentofacial deformity, surgical procedure and intra- and postoperative complications. All of the patients had stable cosmetic results with a high rate of patient satisfaction at the 1-year follow-up examination. No intra- and/or postoperative complications were encountered during any of the different steps of the procedure. This study demonstrated that the application of CAD/CAM patient-specific surgical splints, cutting guides and custom-made implants in orthognathic surgery allows for a successful outcome in the ten patients presented in this series. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  3. Diagnostic yield of preoperative computed tomography imaging and the importance of a clinical decision for lung cancer surgery

    International Nuclear Information System (INIS)

    Sato, Shuichi; Koike, Teruaki; Yamato, Yasushi

    2010-01-01

    This study aimed to evaluate the diagnostic yield of preoperative computed tomography (CT) imaging and the validity of surgical intervention based on the clinical decision to perform surgery for lung cancer or suspected lung cancer. We retrospectively evaluated 1755 patients who had undergone pulmonary resection for lung cancer or suspected lung cancer. CT scans were performed on all patients. Surgical intervention to diagnose and treat was based on a medical staff conference evaluation for the suspected lung cancer patients who were pathologically undiagnosed. We evaluated the relation between resected specimens and preoperative CT imaging in detail. A total of 1289 patients were diagnosed with lung cancer by preoperative pathology examination; another 466 were not pathologically diagnosed preoperatively. Among the 1289 patients preoperatively diagnosed with lung cancer, the diagnoses were confirmed postoperatively in 1282. Among the 466 patients preoperatively undiagnosed, 435 were definitively diagnosed with lung cancer, and there were 383 p-stage I disease patients. There were 38 noncancerous patients who underwent surgery with a diagnosis of confirmed or suspected lung cancer. Among the 1755 patients who underwent surgery, 1717 were pathologically confirmed with lung cancer, and the diagnostic yield of preoperative CT imaging was 97.8%. Among the 466 patients who were preoperatively undiagnosed, 435 were compatible with the predicted findings of lung cancer. Diagnostic yields of preoperative CT imaging based on clinical evaluation are sufficiently reliable. Diagnostic surgical intervention was acceptable when the clinical probability of malignancy was high and the malignancy was pathologically undiagnosed. (author)

  4. Computer assisted surgery with 3D robot models and visualisation of the telesurgical action.

    Science.gov (United States)

    Rovetta, A

    2000-01-01

    This paper deals with the support of virtual reality computer action in the procedures of surgical robotics. Computer support gives a direct representation of the surgical theatre. The modelization of the procedure in course and in development gives a psychological reaction towards safety and reliability. Robots similar to the ones used by the manufacturing industry can be used with little modification as very effective surgical tools. They have high precision, repeatability and are versatile in integrating with the medical instrumentation. Now integrated surgical rooms, with computer and robot-assisted intervention, are operating. The computer is the element for a decision taking aid, and the robot works as a very effective tool.

  5. The value of 201Tl myocardial scintigraphy and of computed tomography for predicting the effectiveness of coronary artery bypass surgery

    International Nuclear Information System (INIS)

    Krosse, B.; Duck, H.J.; Neumann, G.; Huppert, P.; Schulz, H.G.; Lindenau, K.F.

    1986-01-01

    50 male patients with stenosing coronary artery sclerosis and an indication for coronary artery bypass surgery were subjected to pre- and postsurgical 201 Tl scintigraphy and postsurgical computed tomography. Control by angiography was carried out in six cases. Scintigraphy revealed an improved myocardial perfusion in 30 patients, whereas it was unchanged in 15 and deteriorated in 5 patients. Angiography exhibited two cases of graft occlusion, one case of bad run off, and two cases of progressing arteriosclerosis under intact graft. Computed tomography showed that 83 bypasses of the 50 patients were occluded in 6 cases, which was confirmed by angiography in 3 cases. The investigation demonstrates the high value of the two non-invasive methods for the control of bypass patency. (author)

  6. Computed Tomography of the complications of prosthetic surgery of the abdominal aorta

    International Nuclear Information System (INIS)

    Giovagnorio, Francesco; Andreoli, Chiara; De Cicco, Maria Luisa

    1997-01-01

    Computerized Tomography has gained an important role in the diagnosis of the complications of prosthetic surgery of the abdominal aorta: the importance of such complications come from their frequency, which is proportional to the increasing number of interventions, and their severity. The authors investigated the CT patterns of the most frequent complications. 24 patients referred for strongly suspected postoperative complications were examined in 2 years: fever and leukocytosis (20 cases) and progressive anemia (4 cases) were the most frequent findings. The operation had been performed 7± 12 weeks before (2 patients were excluded because surgery dated less than 3 weeks. 14 patients had infective complications: thickening (57%) and inhomogeneity (43%) of the periprosthetic wrap and ectopic gas bubble (78%) were the most frequent Computerized Tomography findings. The authors also observed 2 periprosthetic hematomas, 1 aneurysm relapse and 1 prosthetic graft rupture. In conclusion, CT confirmed its important role in the study of the complications of prosthetic aortic surgery, despite its know poor specificity in the demonstration of the aorta in the first 2-3 months postoperatively, in the initial stages of infection and in the diagnosis of aorta-enteric fistulas

  7. Sinus Surgery

    Science.gov (United States)

    ... sinus computed tomography (CT) scan (without contrast), nasal physiology (rhinomanometry and nasal cytology), smell testing, and selected ... altered anatomical landmarks, or where a patient’s sinus anatomy is very unusual, making typical surgery difficult. Image ...

  8. Outpatient follow-up system using a personal computer for patients with hepatocellular carcinoma after surgery.

    Science.gov (United States)

    Itasaka, H; Matsumata, T; Taketomi, A; Yamamoto, K; Yanaga, K; Takenaka, K; Akazawa, K; Sugimachi, K

    1994-12-01

    A simple outpatient follow-up system was developed with a laptop personal computer to assist management of patients with hepatocellular carcinoma after hepatic resections. Since it is based on a non-relational database program and the graphical user interface of Macintosh operating system, those who are not a specialist of the computer operation can use it. It is helpful to promptly recognize current status and problems of the patients, to diagnose recurrences of the disease and to prevent lost from follow-up cases. A portability of the computer also facilitates utilization of these data everywhere, such as in clinical conferences and laboratories.

  9. Radiation doses to patients receiving computed tomography examinations in British Columbia

    International Nuclear Information System (INIS)

    Aldrich, J.E.; Bilawich, A.-M.; Mayo, J.R.

    2006-01-01

    To estimate the diagnostic reference levels and effective radiation dose to patients from routine computed tomography (CT) examinations in the province of British Columbia, Canada. The patient weight, height and computed tomography dose index or dose linear product (DLP) were recorded on study sheets for 1070 patients who were referred for clinically indicated routine CT examinations at 18 radiology departments in British Columbia. Sixteen of the scanners were multidetector row scanners. The average patient dose varied from hospital to hospital. The largest range was found for CT of the abdomen, for which the dose varied from 3.6 to 26.5 (average 10.1) mSv. For head CT, the range was 1.7 to 4.9 (average 2.8) mSv; for chest CT, it was 3.8 to 26 (average 9.3) mSv; for pelvis CT, it was 3.5 to 15.5 (average 9.0) mSv; and for abdomen/pelvis CT, it was 7.3 to 31.5 (average 16.3) mSv. Reference dose values were calculated for each exam. These DLP values are as follows: head, 1300 mGy cm; chest, 600 mGy cm; abdomen, 920 mGy cm; pelvis, 650 mGy cm; and abdomen/pelvis, 1100 mGy cm. Among hospitals, there was considerable variation in the DLP and patient radiation dose for a specific exam. Reference doses and patient doses were higher than those found in similar recent surveys carried out in the United Kingdom and the European Union. Patient doses were similar to those found in a recent survey in Germany. (author)

  10. Clinical evaluation of a computer-aided diagnosis (CAD) prototype for the detection of pulmonary embolism.

    Science.gov (United States)

    Buhmann, Sonja; Herzog, Peter; Liang, Jin; Wolf, Mathias; Salganicoff, Marcos; Kirchhoff, Chlodwig; Reiser, Maximilian; Becker, Christoph H

    2007-06-01

    To evaluate the performance of a prototype computer-aided diagnosis (CAD) tool using artificial intelligence techniques for the detection of pulmonary embolism (PE) and the possible benefit for general radiologists. Forty multidetector row computed tomography datasets (16/64- channel scanner) using 100 kVp, 100 mAs effective/slice, and 1-mm axial reformats in a low-frequency reconstruction kernel were evaluated. A total of 80 mL iodinated contrast material was injected at a flow rate of 5 mL/seconds. Primarily, six general radiologists marked any PE using a commercially available lung evaluation software with simultaneous, automatic processing by CAD in the background. An expert panel consisting of two chest radiologists analyzed all PE marks from the readers and CAD, also searching for additional finding primarily missed by both, forming the ground truth. The ground truth consisted of 212 emboli. Of these, 65 (31%) were centrally and 147 (69%) were peripherally located. The readers detected 157/212 emboli (74%) leading to a sensitivity of 97% (63/65) for central and 70% (103/147) for peripheral emboli with 9 false-positive findings. CAD detected 168/212 emboli (79%), reaching a sensitivity of 74% for central (48/65) and 82%(120/147) for peripheral emboli. A total of 154 CAD candidates were considered as false positives, yielding an average of 3.85 false positives/case. The CAD software showed a sensitivity comparable to that of the general radiologists, but with more false positives. CAD detection of findings incremental to the radiologists suggests benefit when used as a second reader. Future versions of CAD have the potential to further increase clinical benefit by improving sensitivity and reducing false marks.

  11. Computer aided planning of orthopaedic surgeries: the definition of generic planning steps for bone removal procedures.

    Science.gov (United States)

    Putzer, David; Moctezuma, Jose Luis; Nogler, Michael

    2017-11-01

    An increasing number of orthopaedic surgeons are using computer aided planning tools for bone removal applications. The aim of the study was to consolidate a set of generic functions to be used for a 3D computer assisted planning or simulation. A limited subset of 30 surgical procedures was analyzed and verified in 243 surgical procedures of a surgical atlas. Fourteen generic functions to be used in 3D computer assisted planning and simulations were extracted. Our results showed that the average procedure comprises 14 ± 10 (SD) steps with ten different generic planning steps and four generic bone removal steps. In conclusion, the study shows that with a limited number of 14 planning functions it is possible to perform 243 surgical procedures out of Campbell's Operative Orthopedics atlas. The results may be used as a basis for versatile generic intraoperative planning software.

  12. The use of intraoperative computed tomography navigation in pituitary surgery promises a better intraoperative orientation in special cases

    Directory of Open Access Journals (Sweden)

    Stefan Linsler

    2016-01-01

    Full Text Available Objective: The safety of endoscopic skull base surgery can be enhanced by accurate navigation in preoperative computed tomography (CT and magnetic resonance imaging (MRI. Here, we report our initial experience of real-time intraoperative CT-guided navigation surgery for pituitary tumors in childhood. Materials and Methods: We report the case of a 15-year-old girl with a huge growth hormone-secreting pituitary adenoma with supra- and perisellar extension. Furthermore, the skull base was infiltrated. In this case, we performed an endonasal transsphenoidal approach for debulking the adenoma and for chiasma decompression. We used an MRI neuronavigation (Medtronic Stealth Air System which was registered via intraoperative CT scan (Siemens CT Somatom. Preexisting MRI studies (navigation protocol were fused with the intraoperative CT scans to enable three-dimensional navigation based on MR and CT imaging data. Intraoperatively, we did a further CT scan for resection control. Results: The intraoperative accuracy of the neuronavigation was excellent. There was an adjustment of <1 mm. The navigation was very helpful for orientation on the destroyed skull base in the sphenoid sinus. After opening the sellar region and tumor debulking, we did a CT scan for resection control because the extent of resection was not credible evaluable in this huge infiltrating adenoma. Thereby, we were able to demonstrate a sufficient decompression of the chiasma and complete resection of the medial part of the adenoma in the intraoperative CT images. Conclusions: The use of intraoperative CT/MRI-guided neuronavigation for transsphenoidal surgery is a time-effective, safe, and technically beneficial technique for special cases.

  13. Balancing curability and unnecessary surgery in the context of computed tomography screening for lung cancer.

    Science.gov (United States)

    Flores, Raja; Bauer, Thomas; Aye, Ralph; Andaz, Shahriyour; Kohman, Leslie; Sheppard, Barry; Mayfield, William; Thurer, Richard; Smith, Michael; Korst, Robert; Straznicka, Michaela; Grannis, Fred; Pass, Harvey; Connery, Cliff; Yip, Rowena; Smith, James P; Yankelevitz, David; Henschke, Claudia; Altorki, Nasser

    2014-05-01

    Surgical management is a critical component of computed tomography (CT) screening for lung cancer. We report the results for US sites in a large ongoing screening program, the International Early Lung Cancer Action Program (I-ELCAP). We identified all patients who underwent surgical resection. We compared the results before (1993-2005) and after (2006-2011) termination of the National Lung Screening Trial to identify emerging trends. Among 31,646 baseline and 37,861 annual repeat CT screenings, 492 patients underwent surgical resection; 437 (89%) were diagnosed with lung cancer; 396 (91%) had clinical stage I disease. In the 54 (11%) patients with nonmalignant disease, resection was sublobar in 48 and lobectomy in 6. The estimated cure rate based on the 15-year Kaplan-Meier survival for all 428 patients (excluding 9 typical carcinoids) with lung cancer was 84% (95% confidence interval [CI], 80%-88%) and 88% (95% CI, 83%-92%) for clinical stage I disease resected within 1 month of diagnosis. Video-assisted thoracoscopic surgery and sublobar resection increased significantly, from 10% to 34% (P < .0001) and 22% to 34% (P = .01) respectively; there were no significant differences in the percentage of malignant diagnoses (90% vs 87%, P = .36), clinical stage I (92% vs 89%, P = .33), pathologic stage I (85% vs 82%, P = .44), tumor size (P = .61), or cell type (P = .81). The frequency and extent of surgery for nonmalignant disease can be minimized in a CT screening program and provide a high cure rate for those diagnosed with lung cancer and undergoing surgical resection. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  14. Evaluation of Optic Canal and Surrounding Structures Using Cone Beam Computed Tomography: Considerations for Maxillofacial Surgery.

    Science.gov (United States)

    Sinanoglu, Alper; Orhan, Kaan; Kursun, Sebnem; Inceoglu, Beste; Oztas, Bengi

    2016-07-01

    The optic canal connects the anterior cranial fossa and the orbit and maintains the optic nerve and the ophthalmic artery. Within the extent of the surgical approach of the region, risk of iatrogenic injury of the neural and vascular structures increases. The aim of this retrospective morphometric study is to investigate the radiological anatomy of orbita, optic canal, and its surrounding using cone beam computed tomography (CBCT) scans in a group of Turkish population.Cone beam computed tomography images of a total of 182 patients were evaluated by 2 observers. Anatomical parameters regarding optic canal and orbita were measured for all patients from axial, sagittal, and three-dimensional reconstructed images. To assess intraobserver reliability, the Wilcoxon matched-pairs test was used. Pearson χ test and Student t test were performed for statistical analysis of differences, sex, localization, and measurements (P  0.05). The orbita width and height were larger for the males than females (P  0.05). Examination CBCT scans revealed that the shape of the optic canal was 70% funnel and 28% Hourglass shape, 2% amorph type round.These results provide detailed knowledge of the anatomical characteristics in the orbital area which may be of assistance for surgeons preoperatively. Cone beam computed tomography scans can be an alternative modality for multislice computed tomography with submillimeter resolution and lower dose in preoperative imaging of the orbit.

  15. Online Studies on Variation in Orthopedic Surgery: Computed Tomography in MPEG4 Versus DICOM Format

    NARCIS (Netherlands)

    Mellema, Jos J.; Mallee, Wouter H.; Guitton, Thierry G.; van Dijk, C. Niek; Ring, David; Doornberg, Job N.; Babis, G. C.; Jeray, K. J.; Prayson, M. J.; Pesantez, R.; Acacio, R.; Verbeek, D. O.; Melvanki, P.; Kreis, B. E.; Mehta, S.; Meylaerts, S.; Wojtek, S.; Yeap, E. J.; Haapasalo, H.; Kristan, A.; Coles, C.; Marsh, J. L.; Mormino, M.; Menon, M.; Tyllianakis, M.; Schandelmaier, P.; Jenkinson, R. J.; Neuhaus, V.; Shahriar, C. M. H.; Belangero, W. D.; Kannan, S. G.; Leonidovich, G. M.; Davenport, J. H.; Kabir, K.; Althausen, P. L.; Weil, Y.; Toom, A.; Sa da Costa, D.; Lijoi, F.; Koukoulias, N. E.; Manidakis, N.; van den Bogaert, M.; Patczai, B.; Grauls, A.; Kurup, H.; van den Bekerom, M. P.; Lansdaal, J. R.; Vale, M.; Ousema, P.; Barquet, A.; Cross, B. J.; Broekhuyse, H.; Haverkamp, D.; Merchant, M.; Harvey, E.; Pemovska, E. Stojkovska; Frihagen, F.; Seibert, F. J.; Garnavos, C.; van der Heide, H.; Villamizar, H. A.; Harris, I.; Borris, L. C.; Brink, O.; Brink, P. R. G.; Choudhari, P.; Swiontkowski, M.; Mittlmeier, T.; Tosounidis, T.; van Rensen, I.; Martinelli, N.; Park, D. H.; Lasanianos, N.; Vide, J.; Engvall, A.; Zura, R. D.; Jubel, A.; Kawaguchi, A.; Goost, H.; Bishop, J.; Mica, L.; Pirpiris, M.; van Helden, S. H.; Bouaicha, S.; Schepers, T.; Havliček, T.; Giordano, V.

    2017-01-01

    The purpose of this study was to compare the observer participation and satisfaction as well as interobserver reliability between two online platforms, Science of Variation Group (SOVG) and Traumaplatform Study Collaborative, for the evaluation of complex tibial plateau fractures using computed

  16. Computer-assisted teaching of skin flap surgery: validation of a mobile platform software for medical students.

    Science.gov (United States)

    de Sena, David P; Fabricio, Daniela D; Lopes, Maria Helena I; da Silva, Vinicius D

    2013-01-01

    The purpose of this study was to develop and validate a multimedia software application for mobile platforms to assist in the teaching and learning process of design and construction of a skin flap. Traditional training in surgery is based on learning by doing. Initially, the use of cadavers and animal models appeared to be a valid alternative for training. However, many conflicts with these training models prompted progression to synthetic and virtual reality models. Fifty volunteer fifth- and sixth-year medical students completed a pretest and were randomly allocated into two groups of 25 students each. The control group was exposed for 5 minutes to a standard text-based print article, while the test group used multimedia software describing how to fashion a rhomboid flap. Each group then performed a cutaneous flap on a training bench model while being evaluated by three blinded BSPS (Brazilian Society of Plastic Surgery) board-certified surgeons using the OSATS (Objective Structured Assessment of Technical Skill) protocol and answered a post-test. The text-based group was then tested again using the software. The computer-assisted learning (CAL) group had superior performance as confirmed by checklist scores (pmultimedia method as the best study tool. CAL learners exhibited better subjective and objective performance when fashioning rhomboid flaps as compared to those taught with standard print material. These findings indicate that students preferred to learn using the multimedia method.

  17. Advantages of 18F-fluorodeoxyglucose positron emission tomography combined with computed tomography in detecting post cardiac surgery infections.

    Science.gov (United States)

    Adjtoutah, Djamel; Azhari, Alaa; Larabi, Youcef; Dorigo, Enrica; Merlin, Charles; Marcaggi, Xavier; Nana, Armel Simplice; Camilleri, Lionel; Azarnoush, Kasra

    2014-01-01

    The 18F-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) offers an excellent negative predictive value. Consequently, it is a reliable tool for excluding an infectious phenomenon in case of negativity. In case of persistent fever of unknown origin after cardiac surgery and in combination with other bacteriological examinations and medical imaging, we can rely on FDG-PET/CT to confirm or eliminate deep infections and prosthetic endocarditis. For this reason, FDG-PET/CT should be considered among the examinations to be performed in case of suspected infection after cardiac surgery. We have reported the case of a 76-year-old man who presented with a fever of unknown origin and recurrent septic shocks after a biological Bentall procedure combined with left anterior descending (LAD) coronary artery revascularization by the left internal thoracic artery. We performed a FDG-PET/CT which showed external iliac vein and right common femoral vein hyperfixation with infiltration of adjacent soft tissues, highly suspected to be an infectious process. The aim of this case report is to show that FDG-PET/CT, in combination with other bacteriological examinations and medical imaging, can be extremely helpful in detecting deep infectious sources, even during the early postoperative period.

  18. Computer-assisted operational planning for pediatric abdominal surgery. 3D-visualized MRI with volume rendering

    International Nuclear Information System (INIS)

    Guenther, P.; Holland-Cunz, S.; Waag, K.L.

    2006-01-01

    Exact surgical planning is necessary for complex operations of pathological changes in anatomical structures of the pediatric abdomen. 3D visualization and computer-assisted operational planning based on CT data are being increasingly used for difficult operations in adults. To minimize radiation exposure and for better soft tissue contrast, sonography and MRI are the preferred diagnostic methods in pediatric patients. Because of manifold difficulties 3D visualization of these MRI data has not been realized so far, even though the field of embryonal malformations and tumors could benefit from this. A newly developed and modified raycasting-based powerful 3D volume rendering software (VG Studio Max 1.2) for the planning of pediatric abdominal surgery is presented. With the help of specifically developed algorithms, a useful surgical planning system is demonstrated. Thanks to the easy handling and high-quality visualization with enormous gain of information, the presented system is now an established part of routine surgical planning. (orig.) [de

  19. [Computer-assisted operational planning for pediatric abdominal surgery. 3D-visualized MRI with volume rendering].

    Science.gov (United States)

    Günther, P; Tröger, J; Holland-Cunz, S; Waag, K L; Schenk, J P

    2006-08-01

    Exact surgical planning is necessary for complex operations of pathological changes in anatomical structures of the pediatric abdomen. 3D visualization and computer-assisted operational planning based on CT data are being increasingly used for difficult operations in adults. To minimize radiation exposure and for better soft tissue contrast, sonography and MRI are the preferred diagnostic methods in pediatric patients. Because of manifold difficulties 3D visualization of these MRI data has not been realized so far, even though the field of embryonal malformations and tumors could benefit from this.A newly developed and modified raycasting-based powerful 3D volume rendering software (VG Studio Max 1.2) for the planning of pediatric abdominal surgery is presented. With the help of specifically developed algorithms, a useful surgical planning system is demonstrated. Thanks to the easy handling and high-quality visualization with enormous gain of information, the presented system is now an established part of routine surgical planning.

  20. Social outcome related to cognitive performance and computed tomographic findings after surgery for a ruptured intracranial aneurysm.

    Science.gov (United States)

    Vilkki, J; Holst, P; Ohman, J; Servo, A; Heiskanen, O

    1990-04-01

    A series of 83 patients was examined with a battery of cognitive tests, a clinical interview, and computed tomography 1 year after surgery for a ruptured intracranial aneurysm. Disability on the Glasgow Outcome Scale (33%), failure to return to work (25%), impaired social relations (25%), and subjective or clinical mental impairment (56%) were found to be related to each other and to poor performance on cognitive tests, especially to verbal impairments in patients with left lateral infarctions and to memory deficits and cognitive inflexibility in patients with frontal medial infarctions. Furthermore, cognitive deficits and poor outcome were associated with diffuse brain damage. Depression and anxiety were unrelated to test performances, but were frequently reported by patients with right lateral infarctions.

  1. Automated quantitative coronary computed tomography correlates of myocardial ischaemia on gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Graaf, Michiel A. de; Boogers, Mark J.; Veltman, Caroline E.; El-Naggar, Heba M.; Bax, Jeroen J.; Delgado, Victoria; Broersen, Alexander; Kitslaar, Pieter H.; Dijkstra, Jouke; Kroft, Lucia J.; Younis, Imad Al; Reiber, Johan H.; Scholte, Arthur J.

    2013-01-01

    Automated software tools have permitted more comprehensive, robust and reproducible quantification of coronary stenosis, plaque burden and plaque location of coronary computed tomography angiography (CTA) data. The association between these quantitative CTA (QCT) parameters and the presence of myocardial ischaemia has not been explored. The aim of the present investigation was to evaluate the association between QCT parameters of coronary artery lesions and the presence of myocardial ischaemia on gated myocardial perfusion single-photon emission CT (SPECT). Included in the study were 40 patients (mean age 58.2 ± 10.9 years, 27 men) with known or suspected coronary artery disease (CAD) who had undergone multidetector row CTA and gated myocardial perfusion SPECT within 6 months. From the CTA datasets, vessel-based and lesion-based visual analyses were performed. Consecutively, lesion-based QCT was performed to assess plaque length, plaque burden, percentage lumen area stenosis and remodelling index. Subsequently, the presence of myocardial ischaemia was assessed using the summed difference score (SDS ≥2) on gated myocardial perfusion SPECT. Myocardial ischaemia was seen in 25 patients (62.5 %) in 37 vascular territories. Quantitatively assessed significant stenosis and quantitatively assessed lesion length were independently associated with myocardial ischaemia (OR 7.72, 95 % CI 2.41-24.7, p 2 = 20.7) and lesion length (χ 2 = 26.0) to the clinical variables and the visual assessment (χ 2 = 5.9) had incremental value in the association with myocardial ischaemia. Coronary lesion length and quantitatively assessed significant stenosis were independently associated with myocardial ischaemia. Both quantitative parameters have incremental value over baseline variables and visually assessed significant stenosis. Potentially, QCT can refine assessment of CAD, which may be of potential use for identification of patients with myocardial ischaemia. (orig.)

  2. Availability, Indications, and Technical Performance of Computed Tomographic Colonography: A National Survey

    International Nuclear Information System (INIS)

    Fisichella, V.; Hellstroem, M.

    2006-01-01

    Purpose: To determine the availability, indications, and technique of computed tomographic colonography (CTC) in Sweden and to investigate opinions on its future role in colon imaging. Material and Methods: In May 2004, a questionnaire on CTC was mailed to all Departments of Radiology in Sweden, and one year later a telephone interview was conducted with the departments that intended to start a CTC service. Results: Ninety-nine departments (83%) answered the questionnaire, indicating that 23/99 (23.2%) offered a CTC service. Reasons for non-implementation of CTC were lack of CTC training in 34/73 (46.6%) and non-availability of multi-detector row CT scanners in 33/73 (45.2%), while 26% were awaiting further scientific documentation on CTC. Incomplete colonoscopy was the main indication for CTC in 21/23 (91.3%) departments performing CTC. Dual positioning, room air insufflation, and thin-slice collimation were used in all the responding departments. The number of CTC studies performed varied from 1-5 (26.1%) to more than 200 (17.4%). Intravenous contrast material was routinely administered by 9/23 (39.1%) departments. Out of 30 (39.5%) departments that in 2004 intended to start CTC, 9 (30%) had done so by June 2005. A total of 32/99 (32.3%) departments had therefore started CTC by June 2005. Half of the departments that replied believed that CTC would absolutely or probably replace barium enema in the future. Conclusion: The survey shows relatively limited diffusion of CTC practice in Sweden, with approximately one-third of radiology departments offering a CTC service, mostly on a small scale. A wider dissemination of CTC requires further scientific documentation of its capability, intensified educational efforts, and additional funding

  3. Multidetector computed tomography predictors of late ventricular remodeling and function after acute myocardial infarction

    International Nuclear Information System (INIS)

    Lessick, Jonathan; Abadi, Sobhi; Agmon, Yoram; Keidar, Zohar; Carasso, Shemi; Aronson, Doron; Ghersin, Eduard; Rispler, Shmuel; Sebbag, Anat; Israel, Ora; Hammerman, Haim; Roguin, Ariel

    2012-01-01

    Background: Despite advent of rapid arterial revascularization as 1st line treatment for acute myocardial infarction (AMI), incomplete restoral of flow at the microvascular level remains a problem and is associated with adverse prognosis, including pathological ventricular remodeling. We aimed to study the association between multidetector row computed tomography (MDCT) perfusion defects and ventricular remodeling post-AMI. Methods: In a prospective study, 20 patients with ST-elevation AMI, treated by primary angioplasty, underwent arterial and late phase MDCT as well as radionuclide scans to study presence, size and severity of myocardial perfusion defects. Contrast echocardiography was performed at baseline and at 4 months follow-up to evaluate changes in myocardial function and remodeling. Results: Early defects (ED), late defects (LD) and late enhancement (LE) were detected in 15, 7 and 16 patients, respectively and radionuclide defects in 15 patients. The ED area (r = 0.74), and LD area (r = 0.72), and to a lesser extent LE area (r = 0.62) correlated moderately well with SPECT summed rest score. By univariate analysis, follow-up end-systolic volume index and ejection fraction were both significantly related to ED and LD size and severity, but not to LE size or severity. By multivariate analysis, end-systolic volume index was best predicted by LD area (p < 0.05) and ejection fraction by LD enhancement ratio. Conclusions: LD size and severity on MDCT are most closely associated with pathological ventricular remodeling after AMI and may thus play a role in early identification and treatment of this condition

  4. Quantification of ventilation distribution in regional lung injury by electrical impedance tomography and xenon computed tomography

    International Nuclear Information System (INIS)

    Elke, Gunnar; Weiler, Norbert; Frerichs, Inéz; Fuld, Matthew K; Halaweish, Ahmed F; Hoffman, Eric A; Grychtol, Bartłomiej

    2013-01-01

    Validation studies of electrical impedance tomography (EIT) based assessment of regional ventilation under pathological conditions are required to prove that EIT can reliably quantify heterogeneous ventilation distribution with sufficient accuracy. The objective of our study was to validate EIT measurements of regional ventilation through a comparison with xenon-multidetector-row computed tomography (XeCT) in an animal model of sub-lobar lung injury. Nine anesthetized mechanically ventilated supine pigs were examined before and after the induction of lung injury in two adjacent sub-lobar segments of the right lung by saline lavage or endotoxin instillation. Regional ventilation was determined in 32 anteroposterior regions of interest in the right and left lungs and the ventilation change quantified by difference images between injury and control. Six animals were included in the final analysis. Measurements of regional ventilation by EIT and XeCT correlated well before (r s = 0.89 right, r s = 0.90 left lung) and after local injury (r s = 0.79 and 0.92, respectively). No bias and narrow limits of agreement were found during both conditions. The ventilation decrease in the right injured lung was correspondingly measured by both modalities (5.5%±1.1% by EIT and 5.4%±1.9% by XeCT, p = 0.94). EIT was inferior to clearly separate the exact anatomical location of the regional injuries. Regional ventilation was overestimated (<2%) in the most ventral and dorsal regions and underestimated (2%) in the middle regions by EIT compared to XeCT. This study shows that EIT is able to reliably discern even small ventilation changes on sub-lobar level. (paper)

  5. Accuracy of a Computer-Aided Surgical Simulation (CASS) Protocol for Orthognathic Surgery: A Prospective Multicenter Study

    Science.gov (United States)

    Hsu, Sam Sheng-Pin; Gateno, Jaime; Bell, R. Bryan; Hirsch, David L.; Markiewicz, Michael R.; Teichgraeber, John F.; Zhou, Xiaobo; Xia, James J.

    2012-01-01

    Purpose The purpose of this prospective multicenter study was to assess the accuracy of a computer-aided surgical simulation (CASS) protocol for orthognathic surgery. Materials and Methods The accuracy of the CASS protocol was assessed by comparing planned and postoperative outcomes of 65 consecutive patients enrolled from 3 centers. Computer-generated surgical splints were used for all patients. For the genioplasty, one center utilized computer-generated chin templates to reposition the chin segment only for patients with asymmetry. Standard intraoperative measurements were utilized without the chin templates for the remaining patients. The primary outcome measurements were linear and angular differences for the maxilla, mandible and chin when the planned and postoperative models were registered at the cranium. The secondary outcome measurements were: maxillary dental midline difference between the planned and postoperative positions; and linear and angular differences of the chin segment between the groups with and without the use of the template. The latter was measured when the planned and postoperative models were registered at mandibular body. Statistical analyses were performed, and the accuracy was reported using root mean square deviation (RMSD) and Bland and Altman's method for assessing measurement agreement. Results In the primary outcome measurements, there was no statistically significant difference among the 3 centers for the maxilla and mandible. The largest RMSD was 1.0mm and 1.5° for the maxilla, and 1.1mm and 1.8° for the mandible. For the chin, there was a statistically significant difference between the groups with and without the use of the chin template. The chin template group showed excellent accuracy with largest positional RMSD of 1.0mm and the largest orientational RSMD of 2.2°. However, larger variances were observed in the group not using the chin template. This was significant in anteroposterior and superoinferior directions, as in

  6. Computed tomography assessment of the ethmoid roof: a relevant region at risk in endoscopic sinus surgery

    International Nuclear Information System (INIS)

    Souza, Soraia Ale; Idagawa, Marcos; Wolosker, Angela Maria Borri; Ajzen, Sergio Aron; Souza, Marcia Maria Ale de

    2008-01-01

    Objective: To evaluate the olfactory fossae depth according to the Keros' classification and determine the incidence and degree of asymmetry in the height and contour of the ethmoid roof. Materials and methods: Retrospective analysis of 200 coronal computed tomography studies of paranasal sinuses performed in the period between August and December, 2006. Results: According to the Keros' classification, olfactory fossae type II was most frequently found in 73.3% of cases followed by type I in 26.3% and type III in 0.5% of cases. Asymmetry in the ethmoid roof height was found in 12% of cases (24 computed tomography studies), and contour asymmetry was found in 48.5% (97 computed tomography studies), with flattening of the ethmoid roof on one of the sides. Conclusion: As regards the olfactory fossae depth, the Keros' type II was most frequently found. In most of cases, the ethmoid roof asymmetry was related to angulation of the lateral lamella of the cribriform plate. (author)

  7. Evaluation of patients undergoing lung volume reduction surgery: Ancillary information available from computed tomography

    International Nuclear Information System (INIS)

    Cleverley, Joanne R.; Desai, Sujal R.; Wells, Athol U.; Koyama, Hiroshi; Eastick, Sian; Schmidt, Maria A.; Charrier, Clare L.; Gatehouse, Peter D.; Goldstraw, Peter; Pepper, John R.; Geddes, Duncan M.; Hansell, David M.

    2000-01-01

    AIM: A number of imaging techniques have been used for the pre-operative assessment of patients for lung volume reduction surgery (LVRS). We evaluated whether data currently acquired from perfusion scintigrams and cine MR of the diaphragm are obtainable from high resolution CT (HRCT) of the thorax. MATERIALS AND METHODS: Thirty patients taking part in a randomized controlled trial of LVRS against maximal medical therapy were evaluated. HRCT examinations (n= 30) were scored for (i) the extent and distribution of emphysema; (ii) the extent of normal pulmonary vasculature; and (iii) diaphragmatic contour, apparent defects and herniation. On scintigraphy, (n28), perfusion of the lower thirds of both lungs, as a proportion of total lung perfusion (LZ/T PERF ), was expressed as a percentage of predicted values (derived from 10 normal control subjects). On cine MR (n= 25) hemidiaphragmatic excursion and coordination were recorded. RESULTS: Extensive emphysema was present on HRCT (60% ± 13.2%). There was strong correlation between the extent of normal pulmonary vasculature on HRCT and on perfusion scanning (r s = 0.85, P< 0.00005). Hemidiaphragmatic incoordination on MR was weakly associated with hemidiaphragmatic eventration on HRCT (P0.04). CONCLUSION: The strong correlation between lung perfusion assessed by HRCT and lung perfusion on scintigraphy suggests that perfusion scintigraphy is superfluous in the pre-operative evaluation of patients with emphysema for LVRS. Cleverley, J.R. (2000)

  8. 16-Detector row computed tomographic coronary angiography in patients undergoing evaluation for aortic valve replacement: comparison with catheter angiography

    International Nuclear Information System (INIS)

    Manghat, N.E.; Morgan-Hughes, G.J.; Broadley, A.J.; Undy, M.B.; Wright, D.; Marshall, A.J.; Roobottom, C.A.

    2006-01-01

    Aim: To evaluate the diagnostic accuracy of 16-detector row computed tomography (CT) in assessing haemodynamically significant coronary artery stenoses in patients under evaluation for aortic stenosis pre-aortic valve replacement. Subjects and methods: Forty consecutive patients under evaluation for severe aortic stenosis and listed for cardiac catheterization before potential aortic valve replacement underwent coronary artery calcium (CAC) scoring and retrospective electrocardiogram (ECG)-gated multi-detector row computed tomographic coronary angiography (MDCTA) using a GE Lightspeed 16-detector row CT within 1 month of invasive coronary angiography (ICA) for comparative purposes. All 13 major coronary artery segments of the American Heart Association model were evaluated for the presence of ≥50% stenosis and compared to the reference standard. Data were analysed on a segment-by-segment basis and also in 'whole patient' terms. Results: A total of 412/450 segments from 35 patients were suitable for analysis. The overall accuracy of MDCTA for detection of segments with ≥50% stenosis was high, with a sensitivity of 81.3%, specificity 95.0%, positive predictive value (PPV) 57.8%, and negative predictive value (NPV) 98.4%. On a 'whole-patient' basis, 100% (19/19) of patients with significant coronary disease were correctly identified and there were no false-negatives. Excluding patients with CAC >1000 from the analysis improved the accuracy of MDCTA to: sensitivity 90%, specificity 98.1%, PPV 60%, NPV 99.7%. Conclusion: Non-invasive 16-detector row MDCTA accurately excludes significant coronary disease in patients with severe aortic stenosis undergoing evaluation before aortic valve replacement and in whom ICA can therefore be avoided. Its segment-by-segment accuracy is improved further if CAC > 1000 is used as a gatekeeper to MDCTA

  9. Portal venous gas detected on computed tomography in emergency situations: surgery is still necessary.

    Science.gov (United States)

    Monneuse, Olivier; Pilleul, Frank; Barth, Xavier; Gruner, Laurent; Allaouchiche, Bernard; Valette, Pierre-Jean; Tissot, E

    2007-05-01

    Portal venous gas (PVG) has been reported to be associated with lethal surgical diagnosis. Recent studies tend to confirm the clinical significance of gas in the portal vein; however, some patients are managed without surgical treatment. The aim of this study was to assess both the diagnoses and the treatment of patients with PVG in an emergency surgical setting. We performed a retrospective chart review of 15 patients with PVG in the emergency setting detected by computed tomography (CT) between July 1999 and July 2004. Characteristics assessed included age, sex, clinical presentation, first CT diagnosis of both PVG and the underlying pathology, American Society of Anesthesiologists (ASA) score, surgical findings, final clinical diagnosis, duration of hospitalization, and evolution of the illness/mortality. All patients were examined one month after operation. This series of 5 women and 10 men ranged in age from 38 to 90 years at the time they underwent emergency surgical treatment. The mean preoperative ASA score was 4.20. Computed tomography diagnosed the underlying pathology in all cases: bowel obstruction (4 cases), bowel necrosis (9 cases), and diffuse peritonitis (2 cases). The mean length of hospital stay was 12.4 days. The mortality rate was 46.6%; (7 patients). A wide range of pathologies can generate PVG. Computed tomography can detect both the presence of gas and the underlying pathology. In emergency situations, all the diagnosed causal pathologies required a surgical procedure without delay. We report that the prognosis was related to the pathology itself and was not influenced by the presence of PVG.

  10. Computational fluid dynamics in the assessment of patients' postoperative status after glottis-widening surgery.

    Science.gov (United States)

    Marków, Magdalena; Janecki, Daniel; Orecka, Bogusława; Misiołek, Maciej; Warmuziński, Krzysztof

    2017-09-01

    Computational fluid dynamics (CFD), a rapidly developing instrument with a number of practical applications, allows calculation and visualization of the changing parameters of airflow in the upper respiratory tract. The aim of this study was to demonstrate the advantages of CFD as an instrument for noninvasive tests of the larynx in patients who had undergone surgical treatment due to bilateral vocal fold paralysis. Surface measurements of the glottic space were made during maximum adduction of the vocal folds. Additionally, the following spirometric parameters were determined: forced vital capacity (FVC), forced expiratory volume in the first second (FEV1), and peak expiratory flow (PEF) rate. Based on the measurements, commercial mesh generation software was used to develop a geometrical model of the glottic space. The computations were carried out using a general purpose CFD code. The analysis included patients who were surgically treated for BVFP in the authors' department between 1999 and 2012. The study group consisted of 22 women (91.67%) and 2 men (8.33%). It was observed that the pressure drop calculated for free breathing depends on the area of the glottis and is independent of its shape. Importantly, for areas below approx. 40 mm2, a sudden rise occurred in the resistance to flow; for the smallest glottic areas studied, the pressure drop was almost 6 times higher than for an area of 40 mm2. Consequently, in cases of areas below 40 mm2 even minor enlargement of the glottic opening can lead to a marked improvement in breathing comfort. Computational fluid dynamics is a useful method for calculating and visualizing the changing parameters of airflow in the upper respiratory tract.

  11. Ultralow-dose computed tomography imaging for surgery of midfacial and orbital fractures using ASIR and MBIR.

    Science.gov (United States)

    Widmann, G; Dalla Torre, D; Hoermann, R; Schullian, P; Gassner, E M; Bale, R; Puelacher, W

    2015-04-01

    The influence of dose reductions on diagnostic quality using a series of high-resolution ultralow-dose computed tomography (CT) scans for computer-assisted planning and surgery including the most recent iterative reconstruction algorithms was evaluated and compared with the fracture detectability of a standard cranial emergency protocol. A human cadaver head including the mandible was artificially prepared with midfacial and orbital fractures and scanned using a 64-multislice CT scanner. The CT dose index volume (CTDIvol) and effective doses were calculated using application software. Noise was evaluated as the standard deviation in Hounsfield units within an identical region of interest in the posterior fossa. Diagnostic quality was assessed by consensus reading of a craniomaxillofacial surgeon and radiologist. Compared with the emergency protocol at CTDIvol 35.3 mGy and effective dose 3.6 mSv, low-dose protocols down to CTDIvol 1.0 mGy and 0.1 mSv (97% dose reduction) may be sufficient for the diagnosis of dislocated craniofacial fractures. Non-dislocated fractures may be detected at CTDIvol 2.6 mGy and 0.3 mSv (93% dose reduction). Adaptive statistical iterative reconstruction (ASIR) 50 and 100 reduced average noise by 30% and 56%, and model-based iterative reconstruction (MBIR) by 93%. However, the detection rate of fractures could not be improved due to smoothing effects. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  12. Accuracy of treatment planning based on stereolithography in computer assisted surgery

    International Nuclear Information System (INIS)

    Schicho, Kurt; Figl, Michael; Seemann, Rudolf; Ewers, Rolf; Lambrecht, J. Thomas; Wagner, Arne; Watzinger, Franz; Baumann, Arnulf; Kainberger, Franz; Fruehwald, Julia; Klug, Clemens

    2006-01-01

    Three-dimensional stereolithographic models (SL models), made of solid acrylic resin derived from computed-tomography (CT) data, are an established tool for preoperative treatment planning in numerous fields of medicine. An innovative approach, combining stereolithography with computer-assisted point-to-point navigation, can support the precise surgical realization of a plan that has been defined on an SL model preoperatively. The essential prerequisites for the application of such an approach are: (1) The accuracy of the SL models (including accuracy of the CT scan and correspondence of the model with the patient's anatomy) and (2) the registration method used for the transfer of the plan from the SL model to the patient (i.e., whether the applied registration markers can be added to the SL model corresponding to the markers at the patient with an accuracy that keeps the ''cumulative error'' at the end of the chain of errors, in the order of the accuracy of contemporary navigation systems). In this study, we focus on these two topics: By applying image-matching techniques, we fuse the original CT data of the patient with the corresponding CT data of the scanned SL model, and measure the deviations of defined parameter (e.g., distances between anatomical points). To evaluate the registration method used for the planning transfer, we apply a point-merge algorithm, using four marker points that should be located at exactly corresponding positions at the patient and at connective bars that are added to the surface of the SL model. Again, deviations at defined anatomical structures are measured and analyzed statistically. Our results prove sufficient correspondence of the two data sets and accuracy of the registration method for routine clinical application. The evaluation of the SL model accuracy revealed an arithmetic mean of the relative deviations from 0.8% to 5.4%, with an overall mean deviation of 2.2%. Mean deviations of the investigated anatomical structures

  13. [epiDRB--a new minimally invasive concept for referencing in the field of computer-assisted orthopaedic surgery].

    Science.gov (United States)

    Ohnsorge, J A K; Weisskopf, M; Siebert, C H

    2005-01-01

    Optoelectronic navigation for computer-assisted orthopaedic surgery (CAOS) is based on a firm connection of bone with passive reflectors or active light-emitting diodes in a specific three-dimensional pattern. Even a so-called "minimally-invasive" dynamic reference base (DRB) requires fixation with screws or clamps via incision of the skin. Consequently an originally percutaneous intervention would unnecessarily be extended to an open procedure. Thus, computer-assisted navigation is rarely applied. Due to their tree-like design most DRB's interfere with the surgeon's actions and therefore are at permanent risk to be accidentally dislocated. Accordingly, the optic communication between the camera and the operative site may repeatedly be interrupted. The aim of the research was the development of a less bulky, more comfortable, stable and safely trackable device that can be fixed truly percutaneously. With engineering support of the industrial partner the radiolucent epiDRB was developed. It can be fixed with two or more pins and gains additional stability from its epicutaneous position. The intraoperative applicability and reliability was experimentally tested. Its low centre of gravity and its flat design allow the device to be located directly in the area of interest. Thanks to its epicutaneous position and its particular shape the epiDRB may perpetually be tracked by the navigation system without hindering the surgeon's actions. Hence, the risk of being displaced by accident is minimised and the line of sight remains unaffected. With the newly developed epiDRB computer-assisted navigation becomes easier and safer to handle even in punctures and other percutaneous procedures at the spine as much as at the extremities without an unproportionate amount of additional trauma. Due to the special design referencing of more than one vertebral body is possible at one time, thus decreasing radiation exposure and increasing efficiency.

  14. Computer-assisted preoperative simulation for positioning and fixation of plate in 2-stage procedure combining maxillary advancement by distraction technique and mandibular setback surgery.

    Science.gov (United States)

    Suenaga, Hideyuki; Taniguchi, Asako; Yonenaga, Kazumichi; Hoshi, Kazuto; Takato, Tsuyoshi

    2016-01-01

    Computer-assisted preoperative simulation surgery is employed to plan and interact with the 3D images during the orthognathic procedure. It is useful for positioning and fixation of maxilla by a plate. We report a case of maxillary retrusion by a bilateral cleft lip and palate, in which a 2-stage orthognathic procedure (maxillary advancement by distraction technique and mandibular setback surgery) was performed following a computer-assisted preoperative simulation planning to achieve the positioning and fixation of the plate. A high accuracy was achieved in the present case. A 21-year-old male patient presented to our department with a complaint of maxillary retrusion following bilateral cleft lip and palate. Computer-assisted preoperative simulation with 2-stage orthognathic procedure using distraction technique and mandibular setback surgery was planned. The preoperative planning of the procedure resulted in good aesthetic outcomes. The error of the maxillary position was less than 1mm. The implementation of the computer-assisted preoperative simulation for the positioning and fixation of plate in 2-stage orthognathic procedure using distraction technique and mandibular setback surgery yielded good results. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  15. A cone-beam computed tomography triple scan procedure to obtain a three-dimensional augmented virtual skull model appropriate for orthognathic surgery planning.

    NARCIS (Netherlands)

    Swennen, G.R.J.; Mollemans, W.; Clercq, C. De; Abeloos, J.V.S.; Lamoral, P.; Lippens, F.R.C.; Neyt, N.; Casselman, J.W.; Schutyser, F.A.C.

    2009-01-01

    The aim of this study was to present a new approach to acquire a three-dimensional virtual skull model appropriate for orthognathic surgery planning without the use of plaster dental models and without deformation of the facial soft-tissue mask. A "triple" cone-beam computed tomography (CBCT) scan

  16. Computer-assisted teaching of skin flap surgery: validation of a mobile platform software for medical students.

    Directory of Open Access Journals (Sweden)

    David P de Sena

    Full Text Available The purpose of this study was to develop and validate a multimedia software application for mobile platforms to assist in the teaching and learning process of design and construction of a skin flap. Traditional training in surgery is based on learning by doing. Initially, the use of cadavers and animal models appeared to be a valid alternative for training. However, many conflicts with these training models prompted progression to synthetic and virtual reality models. Fifty volunteer fifth- and sixth-year medical students completed a pretest and were randomly allocated into two groups of 25 students each. The control group was exposed for 5 minutes to a standard text-based print article, while the test group used multimedia software describing how to fashion a rhomboid flap. Each group then performed a cutaneous flap on a training bench model while being evaluated by three blinded BSPS (Brazilian Society of Plastic Surgery board-certified surgeons using the OSATS (Objective Structured Assessment of Technical Skill protocol and answered a post-test. The text-based group was then tested again using the software. The computer-assisted learning (CAL group had superior performance as confirmed by checklist scores (p<0.002, overall global assessment (p = 0.017 and post-test results (p<0.001. All participants ranked the multimedia method as the best study tool. CAL learners exhibited better subjective and objective performance when fashioning rhomboid flaps as compared to those taught with standard print material. These findings indicate that students preferred to learn using the multimedia method.

  17. Evaluation of early coronary graft patency after coronary artery bypass graft surgery using multislice computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Raissi Kamal

    2009-12-01

    Full Text Available Abstract Background Coronary artery bypass graft (CABG surgery is the standard of care in the treatment of advanced coronary artery disease, and its long-term results are affected by the failure of bypass grafts. The aim of the present study was to evaluate the early patency rate in coronary bypass grafts. Methods A total of 107 consecutive patients who underwent CABG were included in this study. Early graft patency was evaluated via computed tomography (CT angiography in the first week after surgery. Results There were a total of 366 grafts, comprised of 250 venous grafts and 116 arterial grafts. Multi-slice CT detected acute graft occlusions in 32 (8.7% of all the grafts, including 26 (10% of the 250 venous grafts and 6 (5% of the 116 arterial grafts. The patency rates obtained were 97.3% for the left internal mammary (IMA grafts, 50% for the radial artery grafts, and 50% for the right IMA grafts. Additionally, 107 (96.4% grafts to the left anterior descending artery (LAD were classified as patent, whereas 1 (30% of the 3 grafts in the left circumflex (LCX region and 1 (50% of the 2 grafts in the right coronary artery (RCA territory were found to be occluded. In the venous category, 8 (13.7% of the 58 grafts to LAD were found to be occluded. In the LCX region, 9 (8.5% of the 106 grafts were classified as occluded, while the remaining 97 (91.5% grafts were patent. The venous grafts to RCA were occluded in 9 (10.4% of the 86 grafts. Amongst the multiple preoperative, intraoperative, and postoperative factors, pump time was significantly longer in the patients with occluded grafts than in those with patent grafts (P = 0.04. Conclusion The IMA grafts had the highest early patency rate amongst the coronary bypass grafts. However, the other arterial grafts were associated with a high rate of acute occlusions.

  18. Online Studies on Variation in Orthopedic Surgery: Computed Tomography in MPEG4 Versus DICOM Format.

    Science.gov (United States)

    Mellema, Jos J; Mallee, Wouter H; Guitton, Thierry G; van Dijk, C Niek; Ring, David; Doornberg, Job N

    2017-10-01

    The purpose of this study was to compare the observer participation and satisfaction as well as interobserver reliability between two online platforms, Science of Variation Group (SOVG) and Traumaplatform Study Collaborative, for the evaluation of complex tibial plateau fractures using computed tomography in MPEG4 and DICOM format. A total of 143 observers started with the online evaluation of 15 complex tibial plateau fractures via either the SOVG or Traumaplatform Study Collaborative websites using MPEG4 videos or a DICOM viewer, respectively. Observers were asked to indicate the absence or presence of four tibial plateau fracture characteristics and to rate their satisfaction with the evaluation as provided by the respective online platforms. The observer participation rate was significantly higher in the SOVG (MPEG4 video) group compared to that in the Traumaplatform Study Collaborative (DICOM viewer) group (75 and 43%, respectively; P video compared to six (range, 1-9) using DICOM viewer (P = 0.11). The interobserver reliability for recognition of fracture characteristics in complex tibial plateau fractures was higher for the evaluation using MPEG4 video. In conclusion, observer participation and interobserver reliability for the characterization of tibial plateau fractures was greater with MPEG4 videos than with a standard DICOM viewer, while there was no difference in observer satisfaction. Future reliability studies should account for the method of delivering images.

  19. Computer-aided detection of lung nodules on chest CT: issues to be solved before clinical use

    International Nuclear Information System (INIS)

    Goo, Jin Mo

    2005-01-01

    Given the increasing resolution of modern CT scanners, and the requirements for large-scale lung-screening examinations and diagnostic studies, there is an increased need for the accurate and reproducible analysis of the large number of images. Nodule detection is one of the main challenges of CT imaging, as they can be missed due to their small size, low relative contrast, or because they are located in an area with complex anatomy. Recent developments in computer-aided diagnosis (CAD) schemes are expected to aid radiologists in various tasks of chest imaging. In this era of multidetector row CT, the thoracic applications of greatest interest include the detection and volume measurement of lung nodules (1-7). Technology for CAD as applied to lung nodule detection on chest CT has been approved by the Food and Drug Administration and is currently commercially available. The article by Lee et al. (5) in this issue of the Korean Journal of Radiology is one of the few studies to examine the influence of a commercially available CAD system on the detection of lung nodules. In this study, some additional nodules were detected with the help of a CAD system, but at the expense of increased false positivity. The nodule detection rate of the CAD system in this study was lower than that achieved by radiologist, and the authors insist that the CAD system should be improved further. Compared to the use of CAD on mammograms, CAD evaluations of chest CTs remain limited to the laboratory setting. In this field, apart from the issues of detection rate and false positive detections, many obstacles must be overcome before CAD can be used in a true clinical reading environment. In this editorial, I will list some of these issues, but I emphasize now that I believe these issues will be solved by improved CAD versions in the near future

  20. Computer-aided detection (CAD) of lung nodules in CT scans: radiologist performance and reading time with incremental CAD assistance

    International Nuclear Information System (INIS)

    Roos, Justus E.; Paik, David; Olsen, David; Liu, Emily G.; Leung, Ann N.; Mindelzun, Robert; Choudhury, Kingshuk R.; Napel, Sandy; Rubin, Geoffrey D.; Chow, Lawrence C.; Naidich, David P.

    2010-01-01

    The diagnostic performance of radiologists using incremental CAD assistance for lung nodule detection on CT and their temporal variation in performance during CAD evaluation was assessed. CAD was applied to 20 chest multidetector-row computed tomography (MDCT) scans containing 190 non-calcified ≥3-mm nodules. After free search, three radiologists independently evaluated a maximum of up to 50 CAD detections/patient. Multiple free-response ROC curves were generated for free search and successive CAD evaluation, by incrementally adding CAD detections one at a time to the radiologists' performance. The sensitivity for free search was 53% (range, 44%-59%) at 1.15 false positives (FP)/patient and increased with CAD to 69% (range, 59-82%) at 1.45 FP/patient. CAD evaluation initially resulted in a sharp rise in sensitivity of 14% with a minimal increase in FP over a time period of 100 s, followed by flattening of the sensitivity increase to only 2%. This transition resulted from a greater prevalence of true positive (TP) versus FP detections at early CAD evaluation and not by a temporal change in readers' performance. The time spent for TP (9.5 s ± 4.5 s) and false negative (FN) (8.4 s ± 6.7 s) detections was similar; FP decisions took two- to three-times longer (14.4 s ± 8.7 s) than true negative (TN) decisions (4.7 s ± 1.3 s). When CAD output is ordered by CAD score, an initial period of rapid performance improvement slows significantly over time because of non-uniformity in the distribution of TP CAD output and not to a changing reader performance over time. (orig.)

  1. A study of the indication for conservative surgery in adult hydronephrosis based on presurgery post-contrast computed tomography (CT) finding

    International Nuclear Information System (INIS)

    Kawai, Noriyasu; Tsugaya, Masayuki; Sakagami, Hiroshi; Sasaki, Shoichi; Kohri, Kenjiro

    1997-01-01

    The cases with adult hydronephrosis are usually performed either conservative surgery or nephrectomy according to the grade of residual renal function. The residual renal function of adult hydronephrosis are usually suspected with analysis of concentration and/or clearance of the renal urine content after percutaneous nephrostomy. However, percutaneous nephrostomy is invasive and risky. On the other hand, post-contrast computed tomography (CT) is non-invasive. We studied whether post-contrast CT is available for the assessment of residual renal function of adult hydronephrosis and also studied the indication for conservative surgery of adult hydronephrosis on post-contrast CT. Conservative surgery or nephrectomy was performed in 14 patients with adult hydronephrosis in the duration from April, 1986 to March, 1995. All of 14 patients (14 kidneys) hydronephrosis were retrospectively studied of the character in the indication for conservative surgery by post-contrast CT before surgery. The indication for conservative surgery of adult hydronephrosis on post-contrast CT are well enhanced renal parenchyma exist round the kidney, even if it is very thin, and excretion of contrast medium to renal calyx are showed. It was concluded that post-contrast CT might be useful for the assessment of residual renal function of adult hydronephrosis. (author)

  2. Automatic bone detection and soft tissue aware ultrasound-CT registration for computer-aided orthopedic surgery.

    Science.gov (United States)

    Wein, Wolfgang; Karamalis, Athanasios; Baumgartner, Adrian; Navab, Nassir

    2015-06-01

    The transfer of preoperative CT data into the tracking system coordinates within an operating room is of high interest for computer-aided orthopedic surgery. In this work, we introduce a solution for intra-operative ultrasound-CT registration of bones. We have developed methods for fully automatic real-time bone detection in ultrasound images and global automatic registration to CT. The bone detection algorithm uses a novel bone-specific feature descriptor and was thoroughly evaluated on both in-vivo and ex-vivo data. A global optimization strategy aligns the bone surface, followed by a soft tissue aware intensity-based registration to provide higher local registration accuracy. We evaluated the system on femur, tibia and fibula anatomy in a cadaver study with human legs, where magnetically tracked bone markers were implanted to yield ground truth information. An overall median system error of 3.7 mm was achieved on 11 datasets. Global and fully automatic registration of bones aquired with ultrasound to CT is feasible, with bone detection and tracking operating in real time for immediate feedback to the surgeon.

  3. Computer-assisted orthognathic surgery: waferless maxillary positioning, versatility, and accuracy of an image-guided visualisation display.

    Science.gov (United States)

    Zinser, Max J; Mischkowski, Robert A; Dreiseidler, Timo; Thamm, Oliver C; Rothamel, Daniel; Zöller, Joachim E

    2013-12-01

    There may well be a shift towards 3-dimensional orthognathic surgery when virtual surgical planning can be applied clinically. We present a computer-assisted protocol that uses surgical navigation supplemented by an interactive image-guided visualisation display (IGVD) to transfer virtual maxillary planning precisely. The aim of this study was to analyse its accuracy and versatility in vivo. The protocol consists of maxillofacial imaging, diagnosis, planning of virtual treatment, and intraoperative surgical transfer using an IGV display. The advantage of the interactive IGV display is that the virtually planned maxilla and its real position can be completely superimposed during operation through a video graphics array (VGA) camera, thereby augmenting the surgeon's 3-dimensional perception. Sixteen adult class III patients were treated with by bimaxillary osteotomy. Seven hard tissue variables were chosen to compare (ΔT1-T0) the virtual maxillary planning (T0) with the postoperative result (T1) using 3-dimensional cephalometry. Clinically acceptable precision for the surgical planning transfer of the maxilla (orthognathic planning. Copyright © 2013 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. Quantitative computed tomography for the prediction of pulmonary function after lung cancer surgery: a simple method using simulation software.

    Science.gov (United States)

    Ueda, Kazuhiro; Tanaka, Toshiki; Li, Tao-Sheng; Tanaka, Nobuyuki; Hamano, Kimikazu

    2009-03-01

    The prediction of pulmonary functional reserve is mandatory in therapeutic decision-making for patients with resectable lung cancer, especially those with underlying lung disease. Volumetric analysis in combination with densitometric analysis of the affected lung lobe or segment with quantitative computed tomography (CT) helps to identify residual pulmonary function, although the utility of this modality needs investigation. The subjects of this prospective study were 30 patients with resectable lung cancer. A three-dimensional CT lung model was created with voxels representing normal lung attenuation (-600 to -910 Hounsfield units). Residual pulmonary function was predicted by drawing a boundary line between the lung to be preserved and that to be resected, directly on the lung model. The predicted values were correlated with the postoperative measured values. The predicted and measured values corresponded well (r=0.89, plung cancer surgery and helped to identify patients whose functional reserves are likely to be underestimated. Hence, this modality should be utilized for patients with marginal pulmonary function.

  5. Computer-assisted surgery simulations and directed practice of total knee arthroplasty: educational benefits to the trainee.

    Science.gov (United States)

    Myden, C A; Anglin, C; Kopp, G D; Hutchison, C R

    2012-01-01

    Orthopaedic residents typically learn to perform total knee arthroplasty (TKA) through an apprenticeship-type model, which is a necessarily slow process. Surgical skills courses, using artificial bones, have been shown to improve technical and cognitive skills significantly within a couple of days. The addition of computer-assisted surgery (CAS) simulations challenges the participants to consider the same task in a different context, promoting cognitive flexibility. We designed a hands-on educational intervention for junior residents with a conventional tibiofemoral TKA station, two different tibiofemoral CAS stations, and a CAS and conventional patellar resection station, including both qualitative and quantitative analyses. Qualitatively, structured interviews before and after the course were analyzed for recurring themes. Quantitatively, subjects were evaluated on their technical skills before and after the course, and on a multiple-choice knowledge test and error detection test after the course, in comparison to senior residents who performed only the testing. Four themes emerged: confidence, awareness, deepening knowledge and changed perspectives. The residents' attitudes to CAS changed from negative before the course to neutral or positive afterwards. The junior resident group completed 23% of tasks in the pre-course skills test and 75% of tasks on the post-test (peducational interventions, promoting cognitive flexibility, would benefit trainees, attending surgeons, the healthcare system and patients.

  6. Surgery of congestive heart failure - the role of computed tomography in the pre- and postsurgical diagnostic evaluation

    International Nuclear Information System (INIS)

    Lembcke, A.; Kivelitz, D.E.; Rogalla, P.; Dewey, M.; Klessen, C.; Hamm, B.; Enzweiler, C.N.H.; Dohmen, P.M.; Konertz, W.F.; Wiese, T.H.

    2005-01-01

    The treatment of advanced, drug resistant congestive heart failure gains in importance in the field of cardiac surgery. Cardiac imaging for preoperative assessment and follow-up focuses on the determination of ventricular volumes and function as well as on the detection of postoperative complications. Computed tomography (CT) is highly accurate irrespective of the individual patient's anatomic situation, has a low examiner dependence and short examination time, does not require an arterial vascular access and can be performed in patients with metal implants. CT is the modality of choice in the follow-up of heart transplants to detect extracardiac and cardiac complications including coronary calcifications as an early sign of transplant vasculopathy. In addition, CT visualizes the elements of mechanical assist devices and can identify their possible local cardiac and mediastinal complications CT can detect fibrolipomatous involution of the mobilized muscle flap in dynamic cardiomyoplasty and can depict fibrous reactions along the epicardial mesh implant in passive cardiac containment. Further indications include assessment of typical local postoperative complications, such as intrathoracic infection and mediastinal bleeding, intracardiac thrombus formation or pericardial effusion. CT is routinely used for evaluating bypass patency but is limited in assessing associated valve defects since it does not visualize flow. (orig.)

  7. Substantial dose reduction in modern multi-slice spiral computed tomography (MSCT)-guided craniofacial and skull base surgery

    International Nuclear Information System (INIS)

    Widmann, G.; Fasser, M.; Jaschke, W.; Bale, R.; Schullian, P.; Zangerl, A.; Puelacher, W.; Kral, F.; Riechelmann, H.

    2012-01-01

    Purpose: Reduction of the radiation exposure involved in image-guided craniofacial and skull base surgery is an important goal. The purpose was to evaluate the influence of low-dose protocols in modern multi-slice spiral computed tomography (MSCT) on target registration errors (TREs). Materials and Methods: An anthropomorphic skull phantom with target markers at the craniofacial bone and the anterior skull base was scanned in Sensation Open (40-slice), LightSpeed VCT (64-slice) and Definition Flash (128-slice). Identical baseline protocols (BP) at 120 kV/100 mAs were compared to the following low-dose protocols (LD) in care dose/dose modulation: (LD-I) 100 kV/35ref. mAs, (LD-II) 80 kV/40 - 41ref. mAs, and (LD-III) 80 kV/15 - 17ref. mAs. CTDIvol and DLP were obtained. TREs using an optical navigation system were calculated for all scanners and protocols. Results were statistically analyzed in SPSS and compared for significant differences (p ≤ 0.05). Results: CTDIvol for the Sensation Open/LightSpeed VCT/Definition Flash showed: (BP) 22.24 /32.48 /14.32 mGy; (LD-I) 4.61 /3.52 /1,62 mGy; (LD-II) 3.15 /2.01 /0.87 mGy; and (LD-III) na/0.76 /0.76 mGy. Differences between the BfS (Bundesamt fuer Strahlenschutz) reference CTDIvol of 9 mGy and the lowest CTDIvol were approximately 3-fold for Sensation Open, and 12-fold for the LightSpeed VCT and Definition Flash. A total of 33 registrations and 297 TRE measurements were performed. In all MSCT scanners, the TREs did not significantly differ between the low-dose and the baseline protocols. Conclusion: Low-dose protocols in modern MSCT provided substantial dose reductions without significant influence on TRE and should be strongly considered in image-guided surgery. (orig.)

  8. The role of computer-aided 3D surgery and stereolithographic modelling for vector orientation in premaxillary and trans-sinusoidal maxillary distraction osteogenesis.

    Science.gov (United States)

    Varol, Altan; Basa, Selçuk

    2009-06-01

    Maxillary distraction osteogenesis is a challenging procedure when it is performed with internal submerged distractors due to obligation of setting accurate distraction vectors. Five patients with severe maxillary retrognathy were planned with Mimics 10.01 CMF and Simplant 10.01 software. Distraction vectors and rods of distractors were arranged in 3D environment and on STL models. All patients were operated under general anaesthesia and complete Le Fort I downfracture was performed. All distractions were performed according to orientated vectors. All patients achieved stable occlusion and satisfactory aesthetic outcome at the end of the treatment period. Preoperative bending of internal maxillary distractors prevents significant loss of operation time. 3D computer-aided surgical simulation and model surgery provide accurate orientation of distraction vectors for premaxillary and internal trans-sinusoidal maxillary distraction. Combination of virtual surgical simulation and stereolithographic models surgery can be validated as an effective method of preoperative planning for complicated maxillofacial surgery cases.

  9. Hip joint centre position estimation using a dual unscented Kalman filter for computer-assisted orthopaedic surgery.

    Science.gov (United States)

    Beretta, Elisa; De Momi, Elena; Camomilla, Valentina; Cereatti, Andrea; Cappozzo, Aurelio; Ferrigno, Giancarlo

    2014-09-01

    In computer-assisted knee surgery, the accuracy of the localization of the femur centre of rotation relative to the hip-bone (hip joint centre) is affected by the unavoidable and untracked pelvic movements because only the femoral pose is acquired during passive pivoting manoeuvres. We present a dual unscented Kalman filter algorithm that allows the estimation of the hip joint centre also using as input the position of a pelvic reference point that can be acquired with a skin marker placed on the hip, without increasing the invasiveness of the surgical procedure. A comparative assessment of the algorithm was carried out using data provided by in vitro experiments mimicking in vivo surgical conditions. Soft tissue artefacts were simulated and superimposed onto the position of a pelvic landmark. Femoral pivoting made of a sequence of star-like quasi-planar movements followed by a circumduction was performed. The dual unscented Kalman filter method proved to be less sensitive to pelvic displacements, which were shown to be larger during the manoeuvres in which the femur was more adducted. Comparable accuracy between all the analysed methods resulted for hip joint centre displacements smaller than 1 mm (error: 2.2 ± [0.2; 0.3] mm, median ± [inter-quartile range 25%; inter-quartile range 75%]) and between 1 and 6 mm (error: 4.8 ± [0.5; 0.8] mm) during planar movements. When the hip joint centre displacement exceeded 6 mm, the dual unscented Kalman filter proved to be more accurate than the other methods by 30% during multi-planar movements (error: 5.2 ± [1.2; 1] mm). © IMechE 2014.

  10. Estimating the effective radiation dose imparted to patients by intraoperative cone-beam computed tomography in thoracolumbar spinal surgery.

    Science.gov (United States)

    Lange, Jeffrey; Karellas, Andrew; Street, John; Eck, Jason C; Lapinsky, Anthony; Connolly, Patrick J; Dipaola, Christian P

    2013-03-01

    Observational. To estimate the radiation dose imparted to patients during typical thoracolumbar spinal surgical scenarios. Minimally invasive techniques continue to become more common in spine surgery. Computer-assisted navigation systems coupled with intraoperative cone-beam computed tomography (CT) represent one such method used to aid in instrumented spinal procedures. Some studies indicate that cone-beam CT technology delivers a relatively low dose of radiation to patients compared with other x-ray-based imaging modalities. The goal of this study was to estimate the radiation exposure to the patient imparted during typical posterior thoracolumbar instrumented spinal procedures, using intraoperative cone-beam CT and to place these values in the context of standard CT doses. Cone-beam CT scans were obtained using Medtronic O-arm (Medtronic, Minneapolis, MN). Thermoluminescence dosimeters were placed in a linear array on a foam-plastic thoracolumbar spine model centered above the radiation source for O-arm presets of lumbar scans for small or large patients. In-air dosimeter measurements were converted to skin surface measurements, using published conversion factors. Dose-length product was calculated from these values. Effective dose was estimated using published effective dose to dose-length product conversion factors. Calculated dosages for many full-length procedures using the small-patient setting fell within the range of published effective doses of abdominal CT scans (1-31 mSv). Calculated dosages for many full-length procedures using the large-patient setting fell within the range of published effective doses of abdominal CT scans when the number of scans did not exceed 3. We have demonstrated that single cone-beam CT scans and most full-length posterior instrumented spinal procedures using O-arm in standard mode would likely impart a radiation dose within the range of those imparted by a single standard CT scan of the abdomen. Radiation dose increases

  11. Application of digital diagnostic impression, virtual planning, and computer-guided implant surgery for a CAD/CAM-fabricated, implant-supported fixed dental prosthesis: a clinical report.

    Science.gov (United States)

    Stapleton, Brandon M; Lin, Wei-Shao; Ntounis, Athanasios; Harris, Bryan T; Morton, Dean

    2014-09-01

    This clinical report demonstrated the use of an implant-supported fixed dental prosthesis fabricated with a contemporary digital approach. The digital diagnostic data acquisition was completed with a digital diagnostic impression with an intraoral scanner and cone-beam computed tomography with a prefabricated universal radiographic template to design a virtual prosthetically driven implant surgical plan. A surgical template fabricated with computer-aided design and computer-aided manufacturing (CAD/CAM) was used to perform computer-guided implant surgery. The definitive digital data were then used to design the definitive CAD/CAM-fabricated fixed dental prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  12. Computed tomography prospective study of pleural-pulmonary changes after abdominal surgery : assessment of associated risk factors

    International Nuclear Information System (INIS)

    Rossi, Luis Antonio; Bromberg, Sansom Henrique

    2005-01-01

    Postoperative pleural-pulmonary changes (PPC) are very common following elective abdominal surgery, resolving without clinical manifestations in most patients. The incidence and risk factors associated are unknown. Objective: to determine the incidence of PPC and possible association with risk factors using computerized tomography (CT). Material and method: thirty seven patients submitted to elective abdominal surgery were prospectively analyzed using CT performed in the preoperative period and 48 hours after surgery. The PPC was scored from 0 to III. The risk factors evaluated were: age, sex, obesity, smoking history, alcoholism, comorbid conditions, cancer, ASA classification, duration of surgery, surgical incision type and number of days of hospitalization. Results: Pleura effusion was detected by CT in 70.3% (26/37) of the patients and pulmonary atelectasis in 75.5% (28/37). Grade I and II PPC was found in 59.5% (22/37) of the patients and grade III in 21.6% (8/37). Two (5.4%) of these patients developed serious pulmonary complications whereas one patient died. Surgery due to cancer, class ASA >2, longitudinal incision and > 15 cm showed statistical significance and were associated with pleural effusion. The hospitalization was over 2.4 longer for patients with PPC. Conclusion: PPC is frequently seen in patients submitted to abdominal surgery. The use of the CT for the detection of pulmonary atelectasis and pleural effusion proved to be effective. Most cases of PPC are self-limited, resolving without symptoms. (author)

  13. Cone Beam Computed Tomography Evaluation of the Diagnosis, Treatment Planning, and Long-Term Followup of Large Periapical Lesions Treated by Endodontic Surgery: Two Case Reports

    Directory of Open Access Journals (Sweden)

    Vijay Shekhar

    2013-01-01

    Full Text Available The aim of this case report is to present two cases where cone beam computed tomography (CBCT was used for the diagnosis, treatment planning, and followup of large periapical lesions in relation to maxillary anterior teeth treated by endodontic surgery. Periapical disease may be detected sooner using CBCT, and their true size, extent, nature, and position can be assessed. It allows clinician to select the most relevant views of the area of interest resulting in improved detection of periapical lesions. CBCT scan may provide a better, more accurate, and faster method to differentially diagnose a solid (granuloma from a fluid-filled lesion or cavity (cyst. In the present case report, endodontic treatment was performed for both the cases followed by endodontic surgery. Biopsy was done to establish the confirmatory histopathological diagnosis of the periapical lesions. Long-term assessment of the periapical healing following surgery was done in all the three dimensions using CBCT and was found to be more accurate than IOPA radiography. It was concluded that CBCT was a useful modality in making the diagnosis and treatment plan and assessing the outcome of endodontic surgery for large periapical lesions.

  14. Cone Beam Computed Tomography Evaluation of the Diagnosis, Treatment Planning, and Long-Term Followup of Large Periapical Lesions Treated by Endodontic Surgery: Two Case Reports

    Science.gov (United States)

    Shekhar, Vijay; Shashikala, K.

    2013-01-01

    The aim of this case report is to present two cases where cone beam computed tomography (CBCT) was used for the diagnosis, treatment planning, and followup of large periapical lesions in relation to maxillary anterior teeth treated by endodontic surgery. Periapical disease may be detected sooner using CBCT, and their true size, extent, nature, and position can be assessed. It allows clinician to select the most relevant views of the area of interest resulting in improved detection of periapical lesions. CBCT scan may provide a better, more accurate, and faster method to differentially diagnose a solid (granuloma) from a fluid-filled lesion or cavity (cyst). In the present case report, endodontic treatment was performed for both the cases followed by endodontic surgery. Biopsy was done to establish the confirmatory histopathological diagnosis of the periapical lesions. Long-term assessment of the periapical healing following surgery was done in all the three dimensions using CBCT and was found to be more accurate than IOPA radiography. It was concluded that CBCT was a useful modality in making the diagnosis and treatment plan and assessing the outcome of endodontic surgery for large periapical lesions. PMID:23762646

  15. Computer-assessed performance of psychomotor skills in endoscopic otolaryngology surgery: construct validity of the Dundee Endoscopic Psychomotor Otolaryngology Surgery Trainer (DEPOST).

    Science.gov (United States)

    Ross, Peter D; Steven, Richard; Zhang, Dong; Li, Heng; Abel, Eric W

    2015-11-01

    This study was undertaken to introduce and establish the value of the Dundee Endoscopic Psychomotor Otolaryngology Surgery Trainer (DEPOST) as a customisable, objective real-time scoring system for trainee assessment. The construct validity of the system was assessed by comparing the performance of experienced otolaryngologists with that of otolaryngology trainees, junior doctors and medical students. Forty two subjects (13 Consultants, 8 senior trainees, 13 junior trainees and 8 junior doctors/medical students) completed a single test on DEPOST. The test involved using a 30° rigid endoscope and a probe with position sensor, to identify a series of lights in a complex 3-dimensional model. The system scored subjects for time, success rate, and economy of movement (distance travelled). An analysis of variance and correlation analysis were used for the data analysis, with statistical significance set at 0.05. Increasing experience led to significantly improved performance with the DEPOST (p < 0.01). Senior trainees' results were significantly better than those of consultant otolaryngologists in success rate and time (p < 0.05 & p < 0.05). Consultants were the most efficient in their movement (p = 0.051) CONCLUSIONS: The system provides an accurate and customisable assessment of endoscopic skill in otolaryngologists. The DEPOST system has construct validity, with master surgeons and senior trainees completing the tasks more accurately without sacrificing execution time, success rate or efficiency of movement.

  16. Algorithm for planning a double-jaw orthognathic surgery using a computer-aided surgical simulation (CASS) protocol. Part 1: planning sequence

    Science.gov (United States)

    Xia, J. J.; Gateno, J.; Teichgraeber, J. F.; Yuan, P.; Chen, K.-C.; Li, J.; Zhang, X.; Tang, Z.; Alfi, D. M.

    2015-01-01

    The success of craniomaxillofacial (CMF) surgery depends not only on the surgical techniques, but also on an accurate surgical plan. The adoption of computer-aided surgical simulation (CASS) has created a paradigm shift in surgical planning. However, planning an orthognathic operation using CASS differs fundamentally from planning using traditional methods. With this in mind, the Surgical Planning Laboratory of Houston Methodist Research Institute has developed a CASS protocol designed specifically for orthognathic surgery. The purpose of this article is to present an algorithm using virtual tools for planning a double-jaw orthognathic operation. This paper will serve as an operation manual for surgeons wanting to incorporate CASS into their clinical practice. PMID:26573562

  17. Three-Dimensional Liver Surgery Simulation: Computer-Assisted Surgical Planning with Three-Dimensional Simulation Software and Three-Dimensional Printing.

    Science.gov (United States)

    Oshiro, Yukio; Ohkohchi, Nobuhiro

    2017-06-01

    To perform accurate hepatectomy without injury, it is necessary to understand the anatomical relationship among the branches of Glisson's sheath, hepatic veins, and tumor. In Japan, three-dimensional (3D) preoperative simulation for liver surgery is becoming increasingly common, and liver 3D modeling and 3D hepatectomy simulation by 3D analysis software for liver surgery have been covered by universal healthcare insurance since 2012. Herein, we review the history of virtual hepatectomy using computer-assisted surgery (CAS) and our research to date, and we discuss the future prospects of CAS. We have used the SYNAPSE VINCENT medical imaging system (Fujifilm Medical, Tokyo, Japan) for 3D visualization and virtual resection of the liver since 2010. We developed a novel fusion imaging technique combining 3D computed tomography (CT) with magnetic resonance imaging (MRI). The fusion image enables us to easily visualize anatomic relationships among the hepatic arteries, portal veins, bile duct, and tumor in the hepatic hilum. In 2013, we developed an original software, called Liversim, which enables real-time deformation of the liver using physical simulation, and a randomized control trial has recently been conducted to evaluate the use of Liversim and SYNAPSE VINCENT for preoperative simulation and planning. Furthermore, we developed a novel hollow 3D-printed liver model whose surface is covered with frames. This model is useful for safe liver resection, has better visibility, and the production cost is reduced to one-third of a previous model. Preoperative simulation and navigation with CAS in liver resection are expected to help planning and conducting a surgery and surgical education. Thus, a novel CAS system will contribute to not only the performance of reliable hepatectomy but also to surgical education.

  18. A computer-supported management of photographic documentation in plastic surgery - System development and its clinical application.

    Science.gov (United States)

    Korczak, Karol; Kasielska-Trojan, Anna; Niedźwiedziński, Marian; Antoszewski, Bogusław

    2017-07-01

    Photographic documentation is very important for plastic, reconstructive, and especially aesthetic surgery procedures. It can be used to improve patient care as well as to carry out scientific research. The results of our previous studies confirmed a strong demand for Information Technology (IT) systems dedicated to plastic surgery. Unfortunately, most of the solutions of this type are not suited to the actual needs. For this reason we decided to develop a reliable system for photographic documentation storage. The Plastic Reconstructive Esthetic Surgery Photo System (PRESsPhoto) was developed and finally deployed in the Plastic, Reconstructive and Aesthetic Surgery Clinic of the Medical University in Łódź (Poland). Preliminary single-center performance tests proved that the PRESsPhoto system is easy to use and provides, inter alia, rapid data search and data entry as well as data security. In the future the PRESsPhoto system should be able to cooperate with Hospital Information Systems (HIS). The process of development and deployment of the PRESsPhoto system is an example of good cooperation between health care providers and the informatics, which resulted in a system that meets the expectations of plastic surgeons. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Preoperative computed tomography of the chest in lung cancer patients: the predictive value of calcified lymph nodes for the perioperative outcomes of video-assisted thoracoscopic surgery lobectomy

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Kwang Nam; Lee, Youkyung; Wi, Jae Yeon [Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Moon, Hyeon-Jong; Sung, Yong Won [Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Department of Cardiothoracic Surgery, Seoul (Korea, Republic of)

    2013-12-15

    To determine the predictive value of identifying calcified lymph nodes (LNs) for the perioperative outcomes of video-assisted thoracoscopic surgery (VATS). Fifty-six consecutive patients who underwent VATS lobectomy for lung cancer were included. We evaluated the number and location of calcified LNs on computed tomography (CT). We investigated clinical parameters, including percentage forced expiratory volume in 1 s (FEV{sub 1}%), surgery duration, chest tube indwelling duration, and length of hospital stay. We performed linear regression analysis and multiple comparisons of perioperative outcomes. Mean number of calcified LNs per patient was 0.9 (range, 0-6), mostly located in the hilar-interlobar zone (43.8 %). For surgery duration (mean, 5.0 h), FEV{sub 1}% and emphysema severity were independent predictors (P = 0.010 and 0.003, respectively). The number of calcified LNs was an independent predictor for chest tube indwelling duration (P = 0.030) and length of hospital stay (P = 0.046). Mean duration of chest tube indwelling and hospital stay was 8.8 days and 12.7 days in no calcified LN group; 9.2 and 13.2 in 1 calcified LN group; 12.8 and 19.7 in {>=}2 calcified LNs group, respectively. The presence of calcified LNs on CT can help predict more complicated perioperative course following VATS lobectomy. (orig.)

  20. Laparoscopy and computed tomography imaging in advanced ovarian tumors: A roadmap for prediction of optimal cytoreductive surgery

    OpenAIRE

    Ahmed Samy El-Agwany

    2018-01-01

    Introduction: Comprehensive staging laparotomy and cytoreductive surgery followed by chemotherapy has been the standard of care in advanced ovarian cancer. Neoadjuvant chemotherapy is an alternative in inoperable advanced cases. To select patients amenable for successful cytoreduction, major determinants including CT imaging and laparoscopy could be of value. There is no general accepted model for selection and reproducibility of techniques are a major challenge due to different clinical prac...

  1. Portable Intraoperative Computed Tomography Scan in Image-Guided Surgery for Brain High-grade Gliomas: Analysis of Technical Feasibility and Impact on Extent of Tumor Resection.

    Science.gov (United States)

    Barbagallo, Giuseppe M V; Palmucci, Stefano; Visocchi, Massimiliano; Paratore, Sabrina; Attinà, Giancarlo; Sortino, Giuseppe; Albanese, Vincenzo; Certo, Francesco

    2016-03-01

    Intraoperative magnetic resonance imaging is the gold standard among image-guided techniques for glioma surgery. Scant data are available on the role of intraoperative computed tomography (i-CT) in high-grade glioma (HGG) surgery. To verify the technical feasibility and usefulness of portable i-CT in image-guided surgical resection of HGGs. This is a retrospective series control analysis of prospectively collected data. Twenty-five patients (Group A) with HGGs underwent surgery using i-CT and 5-aminolevulinic acid (5-ALA) fluorescence. A second cohort of 25 patients (Group B) underwent 5-ALA fluorescence-guided surgery but without i-CT. We used a portable 8-slice CT scanner and, in both groups, neuronavigation. Extent of tumor resection (ETOR) and pre- and postoperative Karnofsky performance status (KPS) scores were measured; the impact of i-CT on overall survival (OS) and progression-free survival (PFS) was also analyzed. In 8 patients (32%) in Group A, i-CT revealed residual tumor, and in 4 of them it helped to also resect pathological tissue detached from the main tumor. EOTR in these 8 patients was 97.3% (96%-98.6%). In Group B, residual tumor was found in 6 patients, whose tumor's mean resection was 98% (93.5-99.7). The Student t test did not show statistically significant differences in EOTR in the 2 groups. The KPS score decreased from 67 to 69 after surgery in Group A and from 74 to 77 in Group B (P = .07 according to the Student t test). Groups A and B did not show statistically significant differences in OS and PFS (P = .61 and .46, respectively, by the log-rank test). No statistically significant differences in EOTR, KPS, PFS, and OS were observed in the 2 groups. However, i-CT helped to verify EOTR and to update the neuronavigator with real-time images, as well as to identify and resect pathological tissue in multifocal tumors. i-CT is a feasible and effective alternative to intraoperative magnetic resonance imaging. Portable i-CT can provide useful

  2. Utility of 3D Reconstruction of 2D Liver Computed Tomography/Magnetic Resonance Images as a Surgical Planning Tool for Residents in Liver Resection Surgery.

    Science.gov (United States)

    Yeo, Caitlin T; MacDonald, Andrew; Ungi, Tamas; Lasso, Andras; Jalink, Diederick; Zevin, Boris; Fichtinger, Gabor; Nanji, Sulaiman

    A fundamental aspect of surgical planning in liver resections is the identification of key vessel tributaries to preserve healthy liver tissue while fully resecting the tumor(s). Current surgical planning relies primarily on the surgeon's ability to mentally reconstruct 2D computed tomography/magnetic resonance (CT/MR) images into 3D and plan resection margins. This creates significant cognitive load, especially for trainees, as it relies on image interpretation, anatomical and surgical knowledge, experience, and spatial sense. The purpose of this study is to determine if 3D reconstruction of preoperative CT/MR images will assist resident-level trainees in making appropriate operative plans for liver resection surgery. Ten preoperative patient CT/MR images were selected. Images were case-matched, 5 to 2D planning and 5 to 3D planning. Images from the 3D group were segmented to create interactive digital models that the resident can manipulate to view the tumor(s) in relation to landmark hepatic structures. Residents were asked to evaluate the images and devise a surgical resection plan for each image. The resident alternated between 2D and 3D planning, in a randomly generated order. The primary outcome was the accuracy of resident's plan compared to expert opinion. Time to devise each surgical plan was the secondary outcome. Residents completed a prestudy and poststudy questionnaire regarding their experience with liver surgery and the 3D planning software. Senior level surgical residents from the Queen's University General Surgery residency program were recruited to participate. A total of 14 residents participated in the study. The median correct response rate was 2 of 5 (40%; range: 0-4) for the 2D group, and 3 of 5 (60%; range: 1-5) for the 3D group (p surgery planning increases accuracy of resident surgical planning and decreases amount of time required. 3D reconstruction would be a useful model for improving trainee understanding of liver anatomy and surgical

  3. [Indication for limited surgery on small lung cancer tumors measuring 1cm or less in diameter on preoperative computed tomography and long-term results].

    Science.gov (United States)

    Togashi, K; Koike, T; Emura, I; Usuda, H

    2008-07-01

    Non-invasive lung cancers showed a good prognosis after limited surgery. But it is still uncertain about invasive lung cancers. We investigated the indications for limited surgery for small lung cancer tumors measuring 1 cm or less in diameter on preoperative computed tomography (CT). This study retrospectively analyzed of 1,245 patients who underwent complete resection of lung cancer between 1989 and 2004 in our hospital. Sixty-two patients (5%) had tumors measuring 1 cm or less in diameter. The probability of survival was calculated using the Kaplan-Meier method. All diseases were detected by medical checkup, 52 % of the patients were not definitively diagnosed with lung cancer before surgery. Adenocarcinoma was histologically diagnosed in 49 patients (79%). Other histologic types included squamous cell carcinoma (8), large cell carcinoma (1), small cell carcinoma (1), carcinoid (2), and adenosquamous cell carcinoma (1). Fifty-seven patients (92%) showed pathologic stage IA. The other stages were IB (2), IIA (1), and IIIB (2). There were 14 bronchioloalveolar carcinomas (25% of IA diseases). The 5-year survival rates of IA patients were 90%. The 5-year survival rate of patients with tumors measuring 1cm or less diameter was 91% after lobectomy or pneumonectomy, and 90% after wedge resection or segmentectomy. There were 3 deaths from cancer recurrence, while there were no deaths in 14 patients with bronchioloalveolar carcinoma After limited surgery, non-invasive cancer showed good long-term results, while invasive cancer showed a recurrence rate of 2.3% to 79% even though the tumor measured 1 cm or less in diameter on preoperative CT.

  4. Handheld single photon emission computed tomography (handheld SPECT) navigated video-assisted thoracoscopic surgery of computer tomography-guided radioactively marked pulmonary lesions.

    Science.gov (United States)

    Müller, Joachim; Putora, Paul Martin; Schneider, Tino; Zeisel, Christoph; Brutsche, Martin; Baty, Florent; Markus, Alexander; Kick, Jochen

    2016-09-01

    Radioactive marking can be a valuable extension to minimally invasive surgery. The technique has been clinically applied in procedures involving sentinel lymph nodes, parathyroidectomy as well as interventions in thoracic surgery. Improvements in equipment and techniques allow one to improve the limits. Pulmonary nodules are frequently surgically removed for diagnostic or therapeutic reasons; here video-assisted thoracoscopic surgery (VATS) is the preferred technique. VATS might be impossible with nodules that are small or located deep in the lung. In this study, we examined the clinical application and safety of employing the newly developed handheld single photon emission tomography (handheld SPECT) device in combination with CT-guided radioactive marking of pulmonary nodules. In this pilot study, 10 subjects requiring surgical resection of a pulmonary nodule were included. The technique involved CT-guided marking of the target nodule with a 20-G needle, with subsequent injection of 25-30 MBq (effective: 7-14 MBq) Tc-99m MAA (Macro Albumin Aggregate). Quality control was made with conventional SPECT-CT to confirm the correct localization and exclude possible complications related to the puncture procedure. VATS was subsequently carried out using the handheld SPECT to localize the radioactivity intraoperatively and therefore the target nodule. A 3D virtual image was superimposed on the intraoperative visual image for surgical guidance. In 9 of the 10 subjects, the radioactive application was successfully placed directly in or in the immediate vicinity of the target nodule. The average size of the involved nodules was 9 mm (range 4-15). All successfully marked nodules were subsequently completely excised (R0) using VATS. The procedure was well tolerated. An asymptomatic clinically insignificant pneumothorax occurred in 5 subjects. Two subjects were found to have non-significant discrete haemorrhage in the infiltration canal of the needle. In a single subject, the

  5. Computed tomography evaluation of autogenous graft in sinus lift surgery; Analise por tomografia computadorizada do enxerto autogeno na cirurgia de 'sinus lift'

    Energy Technology Data Exchange (ETDEWEB)

    Ajzen, Sergio Aron; Moscatiello, Rafael Andrade; Lima, Aida Maria Custodio de; Moscatiello, Vitoria Aparecida Muglia; Helio Kiitiro Yamashita [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. de Diagnostico por Imagem; Mosacatiello, Rafael Muglia; Nishiguchi, Celso Itiro [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Disciplina de Tecnica Operatoria e Cirurgia Experimental; Alves, Maria Teresa de Seixas [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Disciplina de Anatomia Patologica

    2001-02-01

    The objective was to quantify bone formation within autogenous bone grafts and autogenous bone grafts in combination with platelet-rich plasma obtained either from apheresis or centrifugation using computed tomography. This prospective, double-blind study was conducted in 34 male and female adult patients (mean age of 28 years and 8 months), with either unilateral or bilateral pneumatization of the maxillary sinuses, requiring bone graft for dental implant. All patients were submitted to computed tomography examinations prior and six months after sinus lift surgery. Fifty-three maxillary sinuses were operated and divided into three distinct groups: autogenous bone graft, autogenous bone graft in combination with platelet-rich plasma obtained by centrifugation, and autogenous bone graft in combination with platelet-rich plasma obtained by apheresis. The results showed that computed tomography demonstrated bone growth in height and width between the initial and the follow-up computed tomography scans in all three groups. However, no statistical difference was found either for bone height or width. It was concluded that clinical evidence demonstrates the effectiveness of autogenous bone grafts, particularly when used in combination with bone growth factors such as platelet-rich plasma, which allow prosthetic and functional restoration of maxillofacial structures through fixation of dental implants. (author)

  6. Circuito Quirúrgico Informatizado: Una herramienta para la mejora de la atención al paciente quirúrgico Improving the Care level on a surgery-needed patient through a Computer-Aided Surgery Cares Program

    Directory of Open Access Journals (Sweden)

    Luis Fuentes Cebada

    2007-11-01

    Full Text Available El Programa de Atención al Paciente Quirúrgico en el Hospital Puerta del Mar (Cádiz surge con el objetivo de personalizar la atención y garantizar la continuidad de cuidados y la seguridad de nuestros pacientes en cada una de las unidades por las que va desarrollándose la actividad quirúrgica. Este programa se soporta en una herramienta informática que es el circuito quirúrgico, la cual ha sido diseñada siguiendo la metodología de mejora continua y la participación desde el inicio de los profesionales enfermeros como actores de su desarrollo e implantación. En sólo ocho meses se ha conseguido que más del 55 % de los pacientes intervenidos quirúrgicamente disponga de un registro informatizado en el que se valoran, diagnostican, planifican y abordan los aspectos relacionados con la propia intervención quirúrgica como una parte añadida a las respuestas humanas que la misma ocasiona tanto a él como a su familia. Todo ello haciendo uso de las taxonomías enfermeras NANDA, NOC y NIC, con un enfoque holístico, centrado en la persona como agente y receptor de cuidados. Acompaña a este registro un sistema de información desde el que se explotan aspectos tales como la prevalencia diagnóstica enfermera, intervenciones realizadas, alergias, profilaxis antibiótica administrada, etc.The Surgery-needed Care Program, currently under test at the Puerta del Mar Hospital in Cadiz, has been conceived with the aim of both tuning the care level to each individual patient and, at the same time, to secure a continuous assistance through all the units involved in the surgery process. It is based on a computer tool so called Surgery Program. This computer application has been designed on the basis of continually-improving approach while counting with the enrolment, from the very first phases, of nurses in the affected units both in development and set-up steps. After just eight months running this Program, we have been able to create a digital

  7. Diffusion-weighted MR imaging vs. multi-detector row CT: Direct comparison of capability for assessment of management needs for anterior mediastinal solitary tumors

    International Nuclear Information System (INIS)

    Seki, Shinichiro; Koyama, Hisanobu; Ohno, Yoshiharu; Nishio, Mizuho; Takenaka, Daisuke; Maniwa, Yoshimasa; Itoh, Tomoo; Nishimura, Yoshihiro; Sugimura, Kazuro

    2014-01-01

    Purpose: To evaluate and compare the capability of diffusion-weighted MR imaging (DWI) and CT for assessment of management needs for anterior mediastinal solitary tumors. Materials and methods: Thirty-five patients with pathologically confirmed anterior mediastinal tumors were enrolled. The tumors were divided into two groups according to need for management: tumors not needing further intervention or treatment (group A; thymoma type A, AB and B1) and tumors needing further intervention and treatment (group B; other thymoma types and malignancies). The apparent diffusion coefficient (ADC) of each tumor was measured, and probabilities of malignancy and need for further intervention and treatment were visually assessed on CT. The differences in ADCs between group A and B and between malignancies and thymomas in group B were evaluated with the Mann–Whitney's U-test. Feasible threshold values for differentiation of group B from group A and distinguishing malignancies from thymomas assessed as group B were determined by the ROC-based positive test, and McNemar's test was used for comparing diagnostic capabilities of DWI with those of CT. Results: ADCs for the two groups were significantly different (p < 0.001). Application of the threshold value for differentiation of group B from A showed no significant difference (p > 0.05). Application of the feasible threshold value for distinguishing malignant from thymomas assessed as group B showed that specificity (76.9%) and accuracy (85.2%) of DWI were significantly better than those of visual score (p < 0.05). Conclusion: DWI has useful potential for the assessment of management needs for anterior mediastinum solitary tumors as well as CT

  8. Analysis of main influence factors on coronary artery image quality with 64-multidetector row helical CT using a pulsating cardiac phantom

    International Nuclear Information System (INIS)

    Liu Bin; Zhao Hong; Wu Xingwang; Zhang Jiawen; Yu Yongqiang; Liao Jingmin

    2006-01-01

    Objective: To explore the main influence factors (heart rate, rotation speed, and reconstruction algorithm) on the image quality of coronary artery with 40 mm VCT (64-detector row helical CT) using a pulsating cardiac phantom. Methods: An adjustable pulsating cardiac phantom (GE) containing predetermined simulated coronary arteries was scanned using a 40 mm VCT (GE LightSpeed CT) with cardiac pulsating rates of 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, and 115 beats per minute (bpm). The variable rotation speeds technique of 0.35 s, 0.40 s, and 0.45 s were used, respectively. The raw data were reconstructed using both one-sector and multi-sector reconstruction algorithm at optimal window of the R-R interval. The image quality score (IQS) was evaluated by two radiologists according to the same evaluation standard of reformated image. The correlation between heart rate (HR), roation speed, reconstruction algorithm, and IQS were analyzed. The IQS as independent variable and the HR, rotation speed, reconstruction algorithm as dependent variables were analyzed by multiple linear regression analysis. Results: The heart rate and the reconstruction algorithm had significant influence on IQS. The rotation speed (0.35s, 0.40 s, and 0.45 s) didn't have significant influence on IQS. There was linear regression relationship between heart rate, reconstruction algorithm and IQS (P<0.01). The equation of multiple regression was IQS=5.154-0.046 x (HR) + 0.500 x (reconstruction algorithm). The multi-sector reconstruction algorithm improved the image quality than one-sector did. Conclusion: The main influence factors on the image quality of coronary artery can be evaluated with 40 mm VCT using a pulsating cardiac phantom. It plays an important role in clinical research and application. (authors)

  9. Preoperative Diagnosis of Gastric Tumors by Three-dimensional Multidetector Row CT and Double Contrast Barium Meal Study: Correlation with Surgical and Histologic Results

    Directory of Open Access Journals (Sweden)

    Bang-Bin Chen

    2007-11-01

    Conclusion: MDCT has a similar high accuracy in the preoperative diagnosis of different gastric tumors compared with DCBM and provides additional information including tumor depth, lymph node and hepatic metastasis. Therefore, MDCT may be used as a primary tool for preoperative tumor diagnosis and staging.

  10. Chronic thromboembolic pulmonary hypertension (CTEPH). Potential role of multidetector-row CT (MD-CT) and MR imaging in the diagnosis and differential diagnosis of the disease

    Energy Technology Data Exchange (ETDEWEB)

    Wirth, G.; Brueggemann, K.; Bostel, T.; Dueber, C.; Kreitner, K.F. [Universitaetsmedizin Mainz (Germany). Dept. of Radiology; Mayer, E. [Kerckhoff Hospital, Bad Nauheim (Germany). Dept. of Thoracic Surgery

    2014-08-15

    Chronic thromboembolic pulmonary hypertension (CTEPH) can be defined as pulmonary hypertension (resting mean pulmonary arterial pressure of 25 mm Hg or more determined at right heart catheterization) with persistent pulmonary perfusion defects. It is a rare, but underdiagnosed disease with estimated incidences ranging from 0.5% to 3.8% of patients after an acute pulmonary embolism (PE), and in up to 10% of those with a history of recurrent PE. CTEPH is the only form of pulmonary hypertension that can be surgically treated leading to normalization of pulmonary hemodynamics and exercise capacity in the vast majority of patients. The challenges for imaging in patients with suspected CTEPH are fourfold: the imaging modality should have a high diagnostic accuracy with regard to the presence of CTEPH and allow for differential diagnosis. It should enable detection of patients suitable for PEA with great certainty, and allow for quantification of PH by measuring pulmonary hemodynamics (mPAP and PVR), and finally, it can be used for therapy monitoring. This overview tries to elucidate the potential role of ECG-gated multidetector CT pulmonary angiography (MD-CTPA) and MR imaging, and summarizes the most important results that have been achieved so far. Generally speaking, ECG-gated MD-CTPA is superior to MR in the assessment of parenchymal and vascular pathologies of the lung, and allows for the assessment of cardiac structures. The implementation of iodine maps as a surrogate for lung perfusion enables functional assessment of lung perfusion by CT. MR imaging is the reference standard for the assessment of right heart function and lung perfusion, the latter delineating typical wedge-shaped perfusion defects in patients with CTEPH. New developments show that with MR techniques, an estimation of hemodynamic parameters like mean pulmonary arterial pressure and pulmonary vascular resistance will be possible. CT and MR imaging should be considered as complementary investigations providing comprehensive information in patients with CTEPH. (orig.)

  11. 320-Multidetector row whole-head dynamic subtracted CT angiography and whole-brain CT perfusion before and after carotid artery stenting: Technical note

    International Nuclear Information System (INIS)

    San Millan Ruiz, Diego; Murphy, Kieran; Gailloud, Philippe

    2010-01-01

    Introduction: Multidetector CT (MDCT) is increasingly used for the investigation of neurovascular disorders, but restricted z-axis coverage (3.2 cm for 64-MDCT) currently limits perfusion to a small portion of the brain close to the circle of Willis, and precludes dynamic angiographic appreciation of the entire brain circulation. We illustrate the clinical potential of recently developed 320-MDCT extending the z-axis coverage to 16 cm in a patient with symptomatic carotid artery stenosis. Methods: In a 74-year-old patient presenting with critical symptomatic stenosis of the left CCA, pre- and post-carotid artery stenting whole-head subtracted dynamic MDCT angiography and perfusion were obtained in addition to CT angiography of the supra-aortic trunks. Both whole-head subtracted MDCT angiography and perfusion demonstrated delayed left ICA circulation, which normalized after carotid stenting. Discussion: 320-MDCT offers unprecedented z-axis coverage allowing for whole-brain perfusion and subtracted dynamic angiography of the entire intracranial circulation. These innovations can consolidate the role of MDCT as a first intention imaging technique for cerebrovascular disorders, in particular for the acute management of stroke.

  12. Preoperative volume calculation of the hepatic venous draining areas with multi-detector row CT in adult living donor liver transplantation: impact on surgical procedure

    International Nuclear Information System (INIS)

    Frericks, Bernd B.J.; Kirchhoff, Timm D.; Shin, Hoen-Oh; Stamm, Georg; Merkesdal, Sonja; Abe, Takehiko; Galanski, Michael; Schenk, Andrea; Peitgen, Heinz-Otto; Klempnauer, Juergen; Nashan, Bjoern

    2006-01-01

    The purpose was to assess the volumes of the different hepatic territories and especially the drainage of the right paramedian sector in adult living donor liver transplantation (ALDLT). CT was performed in 40 potential donors of whom 28 underwent partial living donation. Data sets of all potential donors were postprocessed using dedicated software for segmentation, volumetric analysis and visualization of liver territories. During an initial period, volumes and shapes of liver parts were calculated based on the individual portal venous perfusion areas. After partial hepatic congestion occurring in three grafts, drainage territories with special regard to MHV tributaries from the right paramedian sector, and the IRHV were calculated additionally. Results were visualized three-dimensionally and compared to the intraoperative findings. Calculated graft volumes based on hepatic venous drainage and graft weights correlated significantly (r=0.86,P<0.001). Mean virtual graft volume was 930 ml and drained as follows: RHV: 680 ml, IRHV: 170 ml (n=11); segment 5 MHV tributaries: 100 ml (n=16); segment 8 MHV tributaries: 110 ml (n=20). When present, the mean aberrant venous drainage fraction of the right liver lobe was 28%. The evaluated protocol allowed a reliable calculation of the hepatic venous draining areas and led to a change in the hepatic venous reconstruction strategy at our institution. (orig.)

  13. Assessment of coronary artery aneurysms in paediatric patients with Kawasaki disease by multidetector row CT angiography: feasibility and comparison with 2D echocardiography

    International Nuclear Information System (INIS)

    Chu, W.C.W.; Lam, W.W.M.; Mok, G.C.F.; Yam, M.; Sung, R.Y.T.

    2006-01-01

    Transthoracic ECHO is the locally accepted method for coronary surveillance of patients with Kawasaki disease but it may have limited visualization in the older child. To assess the feasibility of multidetector CT (MDCT) angiography in the follow-up of coronary artery aneurysms in children with previous Kawasaki disease. Six children (5 boys, 1 girl; mean age 11.5 years) with known Kawasaki disease and coronary artery involvement underwent CT coronary angiography using 16-detector MDCT. The visualized lengths and diameter of all coronary segments were measured. The number, size and location of coronary artery aneurysms were recorded and compared with recent ECHO. Twelve coronary artery aneurysms (seven saccular, five fusiform) were identified by MDCT angiography. One saccular aneurysm at the junction of the distal right coronary artery and posterior descending artery was not detected by ECHO while the remaining six in proximal segments were detected by both modalities. Two of five fusiform aneurysms were not detected by ECHO due to their small sizes. Excellent agreement was found between CT and ECHO for maximal diameter and length of the visualized aneurysms. MDCT angiography accurately defines coronary artery aneurysms. It is more sensitive for detecting aneurysms at distal coronary segments and fusiform aneurysms of small size

  14. Computational modeling of blood flow in the aorta--insights into eccentric dilatation of the ascending aorta after surgery for coarctation.

    Science.gov (United States)

    Szopos, Marcela; Poussineau, Nicole; Maday, Yvon; Canniffe, Carla; Celermajer, David S; Bonnet, Damien; Ou, Phalla

    2014-10-01

    To assess whether combining a computational modeling technique with data from patient magnetic resonance imaging studies can detect different fluid dynamics and vascular biomechanical properties of the ascending and horizontal aorta in patients with angulated "gothic" arch geometry compared with those with normal "Romanesque" arch geometry after aortic coarctation repair. Advanced computational fluid dynamics techniques (coupled Navier-Stokes and elastodynamics equations) were used to predict the fluid-wall interactions in large arteries. We modeled the fluid dynamics and shear stress in the ascending and horizontal aorta in cases of "gothic" arch and normal "Romanesque" aortic arch geometry. A total of 30 patients after aortic coarctation repair prospectively underwent 3-dimensional magnetic resonance imaging angiography of the thoracic aorta. Measurements of the ascending and horizontal aorta were assessed using multiplanar reformatting images. Our computational model demonstrated that wall shear stress is greater in those with an angulated "gothic" aortic arch than in those with a "Romanesque" arch. In particular, wall shear stress affected the anterior and posterior segments of the ascending aorta and the inferior and superior segments of the horizontal aorta (vs the left and right segments). In vivo, a "gothic" arch was associated with dilatation of the ascending and horizontal aorta, which was eccentric rather than concentric (Pgothic" aortic arch after repair of coarctation. This suggests that patients with an angulated "gothic" aortic arch might warrant increased surveillance for aortic complications. Copyright © 2014 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  15. Computed tomography of renal cell carcinoma in patients with terminal renal impairment

    International Nuclear Information System (INIS)

    Ferda, Jiri; Hora, Milan; Hes, Ondrej; Reischig, Tomas; Kreuzberg, Boris; Mirka, Hynek; Ferdova, Eva; Ohlidalova, Kristyna; Baxa, Jan; Urge, Tomas

    2007-01-01

    Purpose: An increased incidence of renal tumors has been observed in patients with end-stage-renal-disease (ESRD). The very strong association with acquired renal cystic disease (ACRD) and increased incidence of the renal tumors (conventional renal cell carcinoma (CRCC), papillary renal cell carcinoma (PRCC) or papillary renal cell adenoma (PRCA)) was reported. This study discusses the role of computed tomography (CT) in detecting renal tumors in patients with renal impairment: pre-dialysis, those receiving dialysis or with renal allograft transplants. Materials and methods: Ten patients (nine male, one female) with renal cell tumors were enrolled into a retrospective study; two were new dialysis patients, three on long-term dialysis, and five were renal transplant recipients with history of dialysis. All patients underwent helical CT, a total of 11 procedures were performed. Sixteen-row detector system was used five times, and a 64-row detector system for the six examinations. All patients underwent nephrectomy of kidney with suspected tumor, 15 nephrectomies were performed, and 1 kidney was assessed during autopsy. CT findings were compared with macroscopic and microscopic assessments of the kidney specimen in 16 cases. Results: Very advanced renal parenchyma atrophy with small cysts corresponding to ESRD was found in nine patients, chronic pyelonephritis in remained one. A spontaneously ruptured tumor was detected incidentally in one case, patient died 2 years later. In the present study, 6.25% (1/16) were multiple PRCA, 12.5% (2/16) were solitary PRCC, 12.5% tumors (2/16) were solitary conventional renal cell carcinomas (CRCC's), 12.5% tumors (2/16) were multiple conventional renal cell carcinomas (CRCC's), 25% (4/16) were CRCC's combined with multiple papillary renal cell carcinomas with adenomas (PRCC's and PRCA's), and 25% (4/16) of the tumors were multiple PRCC's combined with PRCA's without coexisting CRCC's. Bilateral renal tumors were found in our study

  16. Automated quantitative coronary computed tomography correlates of myocardial ischaemia on gated myocardial perfusion SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Graaf, Michiel A. de; Boogers, Mark J.; Veltman, Caroline E. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); The Interuniversity Cardiology Institute of The Netherlands, Utrecht (Netherlands); El-Naggar, Heba M.; Bax, Jeroen J.; Delgado, Victoria [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands); Broersen, Alexander; Kitslaar, Pieter H.; Dijkstra, Jouke [Leiden University Medical Center, Department of Radiology, Division of Image Processing, Leiden (Netherlands); Kroft, Lucia J. [Leiden University Medical Center, Department of Radiology, Leiden (Netherlands); Younis, Imad Al [Leiden University Medical Center, Department of Nuclear Medicine, Leiden (Netherlands); Reiber, Johan H. [Leiden University Medical Center, Department of Radiology, Division of Image Processing, Leiden (Netherlands); Medis medical imaging systems B.V., Leiden (Netherlands); Scholte, Arthur J. [Leiden University Medical Center, Department of Cardiology, Leiden (Netherlands)

    2013-08-15

    Automated software tools have permitted more comprehensive, robust and reproducible quantification of coronary stenosis, plaque burden and plaque location of coronary computed tomography angiography (CTA) data. The association between these quantitative CTA (QCT) parameters and the presence of myocardial ischaemia has not been explored. The aim of the present investigation was to evaluate the association between QCT parameters of coronary artery lesions and the presence of myocardial ischaemia on gated myocardial perfusion single-photon emission CT (SPECT). Included in the study were 40 patients (mean age 58.2 {+-} 10.9 years, 27 men) with known or suspected coronary artery disease (CAD) who had undergone multidetector row CTA and gated myocardial perfusion SPECT within 6 months. From the CTA datasets, vessel-based and lesion-based visual analyses were performed. Consecutively, lesion-based QCT was performed to assess plaque length, plaque burden, percentage lumen area stenosis and remodelling index. Subsequently, the presence of myocardial ischaemia was assessed using the summed difference score (SDS {>=}2) on gated myocardial perfusion SPECT. Myocardial ischaemia was seen in 25 patients (62.5 %) in 37 vascular territories. Quantitatively assessed significant stenosis and quantitatively assessed lesion length were independently associated with myocardial ischaemia (OR 7.72, 95 % CI 2.41-24.7, p < 0.001, and OR 1.07, 95 % CI 1.00-1.45, p = 0.032, respectively) after correcting for clinical variables and visually assessed significant stenosis. The addition of quantitatively assessed significant stenosis ({chi} {sup 2} = 20.7) and lesion length ({chi} {sup 2} = 26.0) to the clinical variables and the visual assessment ({chi} {sup 2} = 5.9) had incremental value in the association with myocardial ischaemia. Coronary lesion length and quantitatively assessed significant stenosis were independently associated with myocardial ischaemia. Both quantitative parameters have

  17. Precision of dosimetry-related measurements obtained on current multidetector computed tomography scanners

    International Nuclear Information System (INIS)

    Mathieu, Kelsey B.; McNitt-Gray, Michael F.; Zhang, Di; Kim, Hyun J.; Cody, Dianna D.

    2010-01-01

    Purpose: Computed tomography (CT) intrascanner and interscanner variability has not been well characterized. Thus, the purpose of this study was to examine the within-run, between-run, and between-scanner precision of physical dosimetry-related measurements collected over the course of 1 yr on three different makes and models of multidetector row CT (MDCT) scanners. Methods: Physical measurements were collected using nine CT scanners (three scanners each of GE VCT, GE LightSpeed 16, and Siemens Sensation 64 CT). Measurements were made using various combinations of technical factors, including kVp, type of bowtie filter, and x-ray beam collimation, for several dosimetry-related quantities, including (a) free-in-air CT dose index (CTDI 100,air ); (b) calculated half-value layers and quarter-value layers; and (c) weighted CT dose index (CTDI w ) calculated from exposure measurements collected in both a 16 and 32 cm diameter CTDI phantom. Data collection was repeated at several different time intervals, ranging from seconds (for CTDI 100,air values) to weekly for 3 weeks and then quarterly or triannually for 1 yr. Precision of the data was quantified by the percent coefficient of variation (%CV). Results: The maximum relative precision error (maximum %CV value) across all dosimetry metrics, time periods, and scanners included in this study was 4.33%. The median observed %CV values for CTDI 100,air ranged from 0.05% to 0.19% over several seconds, 0.12%-0.52% over 1 week, and 0.58%-2.31% over 3-4 months. For CTDI w for a 16 and 32 cm CTDI phantom, respectively, the range of median %CVs was 0.38%-1.14% and 0.62%-1.23% in data gathered weekly for 3 weeks and 1.32%-2.79% and 0.84%-2.47% in data gathered quarterly or triannually for 1 yr. Conclusions: From a dosimetry perspective, the MDCT scanners tested in this study demonstrated a high degree of within-run, between-run, and between-scanner precision (with relative precision errors typically well under 5%).

  18. Computer assisted surgical anatomy mapping : applications in surgical anatomy research, tailor-made surgery and presonalized teaching

    NARCIS (Netherlands)

    A.L.A. Kerver (Anton)

    2017-01-01

    markdownabstractThis thesis presents a novel anatomy mapping tool named Computer Assisted Surgical Anatomy Mapping (CASAM). It allows researchers to map complex anatomy of multiple specimens and compare their location and course. Renditions such as safe zones or danger zones can be visualized,

  19. Electronic remote blood issue combined with a computer-controlled, automated refrigerator for major surgery in operating theatres at a distance from the transfusion service.

    Science.gov (United States)

    Verlicchi, Franco; Pacilli, Pasqua; Bragliani, Arianna; Rapuano, Silvia; Dini, Daniele; Vincenzi, Daniele

    2018-02-01

    The difficulty of supplying red blood cells within an adequate time to patients undergoing surgery is a known problem for transfusion services, particularly if the operating theater is located at some distance from the blood bank. The consequences frequently are that more blood is ordered than required; several units are allocated and issued; and unused units must be returned to the blood bank. Some sparse reports have demonstrated that remote blood issue systems can improve the efficiency of issuing blood. This study describes a computer-controlled, self-service, remote blood-release system, combined with an automated refrigerator, installed in a hospital at which major surgery was performed, located 5 kilometers away from the transfusion service. With this system, red blood cell units were electronically allocated to patients immediately before release, when the units actually were needed. Two 2-year periods, before and after implementation of the system, were compared. After implementation of the system, the ratio of red blood cell units returned to the transfusion service was reduced from 48.9% to 1.6% of the issued units (8852 of 18,090 vs. 182 of 11,152 units; p blood cell units was observed, probably mainly due to changes in the number and complexity of surgical procedures. No transfusion errors occurred in the two periods. The current results demonstrate that the remote blood-release system is safe and useful for improving the efficiency of blood issue for patients in remote operating theatres. © 2017 AABB.

  20. Dipyridamole thallium-201 single-photon emission computed tomography for prediction of perioperative cardiac events in patients with arteriosclerosis obliterans undergoing vascular surgery

    International Nuclear Information System (INIS)

    Ziyang, Huang; Komori, Sadayoshi; Sawanobori, Takao

    1998-01-01

    The aim of the study was to determine whether or not dipyridamole thallium-201 single-photon emission computed tomography ( 201 Tl-SPECT) has significant additive value for predicting perioperative cardiac events in patients with arteriosclerosis obliterans (ASO) undergoing vascular surgery. Routine preoperative 201 Tl-SPECT was performed in 106 consecutive patients with ASO (age 68±8.9 years; 91 men and 15 women). The frequency of reversible defects in a clinical high-risk group (n=44) was significantly higher than in a low-risk group (n=62; 55% vs 24%, p 201 Tl-SPECT data to clinical risk-stratified patients with ASO allows better prediction of perioperative cardiac events. (author)

  1. COMPUTING

    CERN Multimedia

    M. Kasemann

    Overview In autumn the main focus was to process and handle CRAFT data and to perform the Summer08 MC production. The operational aspects were well covered by regular Computing Shifts, experts on duty and Computing Run Coordination. At the Computing Resource Board (CRB) in October a model to account for service work at Tier 2s was approved. The computing resources for 2009 were reviewed for presentation at the C-RRB. The quarterly resource monitoring is continuing. Facilities/Infrastructure operations Operations during CRAFT data taking ran fine. This proved to be a very valuable experience for T0 workflows and operations. The transfers of custodial data to most T1s went smoothly. A first round of reprocessing started at the Tier-1 centers end of November; it will take about two weeks. The Computing Shifts procedure was tested full scale during this period and proved to be very efficient: 30 Computing Shifts Persons (CSP) and 10 Computing Resources Coordinators (CRC). The shift program for the shut down w...

  2. Comparative analysis of the results of surgery for juvenile nasopharyngeal angiofibroma with the use of 3D reconstructions of computed tomography angiography

    Directory of Open Access Journals (Sweden)

    N. S. Grachev

    2017-01-01

    Full Text Available Rationale: The relapse rates after surgery for juvenile nasopharyngeal and/or skull base angiofibroma is in the range of 23 to 27.5%, which is mostly related to diagnostic issues. Aim: To perform a comparative analysis of the results of surgical treatment for juvenile nasopharyngeal and skull base angiofibroma based on our technique of 3D reconstructions of computed tomography angiograms in patients with primary tumors and with relapses. Materials and methods: We analyzed retrospectively the data from 32 patients with juvenile nasopharyngeal and skull base angiofibroma who had been diagnosed and treated from 2013 to 2017 (42 surgeries. Multislice computed tomography (MSCT angiography with 3D reconstruction was used for the planning of surgical approaches. At days 3 to 7 after the surgery, in 31 patients with stages II, IIIa and IIIb (according to U. Fisch classification modified by R. Andrews, 1989, we looked for residual tumor tissues by MSCT with standard analysis and with 3D MSCT angiography reconstructions, comparing them with their corresponding baseline images. The patients were divided into two groups: group 1, 17 patients with primary tumors (median age 13.5 years, group 2, 14 patients who had been previously operated (median age 14 years. Both groups were comparable in their clinical and demographic characteristics, as well as in the tumor staging (p > 0.05. Results: The relapse rates were 22.58% (7 / 31 patients, being 11.76% (2 / 17 in the group 1 and 35.71% (5 / 14 in the group 2 (p > 0.05. In each group, the maximal difference in the resected tumor volume was found in stage II patients, with more radical resection in the patients with primary tumors (p < 0.05. Contrast-enhanced MSCT showed residual tumor masses in 19 patients (8, with primary tumors and 11, with relapses. From those, 10 patients (3 with primary tumors and 7 who had underwent surgery earlier required second surgeries (4 patients were curatively operated, and 2

  3. COMPUTING

    CERN Multimedia

    I. Fisk

    2011-01-01

    Introduction CMS distributed computing system performed well during the 2011 start-up. The events in 2011 have more pile-up and are more complex than last year; this results in longer reconstruction times and harder events to simulate. Significant increases in computing capacity were delivered in April for all computing tiers, and the utilisation and load is close to the planning predictions. All computing centre tiers performed their expected functionalities. Heavy-Ion Programme The CMS Heavy-Ion Programme had a very strong showing at the Quark Matter conference. A large number of analyses were shown. The dedicated heavy-ion reconstruction facility at the Vanderbilt Tier-2 is still involved in some commissioning activities, but is available for processing and analysis. Facilities and Infrastructure Operations Facility and Infrastructure operations have been active with operations and several important deployment tasks. Facilities participated in the testing and deployment of WMAgent and WorkQueue+Request...

  4. COMPUTING

    CERN Multimedia

    P. McBride

    The Computing Project is preparing for a busy year where the primary emphasis of the project moves towards steady operations. Following the very successful completion of Computing Software and Analysis challenge, CSA06, last fall, we have reorganized and established four groups in computing area: Commissioning, User Support, Facility/Infrastructure Operations and Data Operations. These groups work closely together with groups from the Offline Project in planning for data processing and operations. Monte Carlo production has continued since CSA06, with about 30M events produced each month to be used for HLT studies and physics validation. Monte Carlo production will continue throughout the year in the preparation of large samples for physics and detector studies ramping to 50 M events/month for CSA07. Commissioning of the full CMS computing system is a major goal for 2007. Site monitoring is an important commissioning component and work is ongoing to devise CMS specific tests to be included in Service Availa...

  5. COMPUTING

    CERN Multimedia

    M. Kasemann

    Overview During the past three months activities were focused on data operations, testing and re-enforcing shift and operational procedures for data production and transfer, MC production and on user support. Planning of the computing resources in view of the new LHC calendar in ongoing. Two new task forces were created for supporting the integration work: Site Commissioning, which develops tools helping distributed sites to monitor job and data workflows, and Analysis Support, collecting the user experience and feedback during analysis activities and developing tools to increase efficiency. The development plan for DMWM for 2009/2011 was developed at the beginning of the year, based on the requirements from the Physics, Computing and Offline groups (see Offline section). The Computing management meeting at FermiLab on February 19th and 20th was an excellent opportunity discussing the impact and for addressing issues and solutions to the main challenges facing CMS computing. The lack of manpower is particul...

  6. Minimally invasive registration for computer-assisted orthopedic surgery: combining tracked ultrasound and bone surface points via the P-IMLOP algorithm.

    Science.gov (United States)

    Billings, Seth; Kang, Hyun Jae; Cheng, Alexis; Boctor, Emad; Kazanzides, Peter; Taylor, Russell

    2015-06-01

    We present a registration method for computer-assisted total hip replacement (THR) surgery, which we demonstrate to improve the state of the art by both reducing the invasiveness of current methods and increasing registration accuracy. A critical element of computer-guided procedures is the determination of the spatial correspondence between the patient and a computational model of patient anatomy. The current method for establishing this correspondence in robot-assisted THR is to register points intraoperatively sampled by a tracked pointer from the exposed proximal femur and, via auxiliary incisions, from the distal femur. In this paper, we demonstrate a noninvasive technique for sampling points on the distal femur using tracked B-mode ultrasound imaging and present a new algorithm for registering these data called Projected Iterative Most-Likely Oriented Point (P-IMLOP). Points and normal orientations of the distal bone surface are segmented from ultrasound images and registered to the patient model along with points sampled from the exposed proximal femur via a tracked pointer. The proposed approach is evaluated using a bone- and tissue-mimicking leg phantom constructed to enable accurate assessment of experimental registration accuracy with respect to a CT-image-based model of the phantom. These experiments demonstrate that localization of the femur shaft is greatly improved by tracked ultrasound. The experiments further demonstrate that, for ultrasound-based data, the P-IMLOP algorithm significantly improves registration accuracy compared to the standard ICP algorithm. Registration via tracked ultrasound and the P-IMLOP algorithm has high potential to reduce the invasiveness and improve the registration accuracy of computer-assisted orthopedic procedures.

  7. A Tissue Relevance and Meshing Method for Computing Patient-Specific Anatomical Models in Endoscopic Sinus Surgery Simulation

    Science.gov (United States)

    Audette, M. A.; Hertel, I.; Burgert, O.; Strauss, G.

    This paper presents on-going work on a method for determining which subvolumes of a patient-specific tissue map, extracted from CT data of the head, are relevant to simulating endoscopic sinus surgery of that individual, and for decomposing these relevant tissues into triangles and tetrahedra whose mesh size is well controlled. The overall goal is to limit the complexity of the real-time biomechanical interaction while ensuring the clinical relevance of the simulation. Relevant tissues are determined as the union of the pathology present in the patient, of critical tissues deemed to be near the intended surgical path or pathology, and of bone and soft tissue near the intended path, pathology or critical tissues. The processing of tissues, prior to meshing, is based on the Fast Marching method applied under various guises, in a conditional manner that is related to tissue classes. The meshing is based on an adaptation of a meshing method of ours, which combines the Marching Tetrahedra method and the discrete Simplex mesh surface model to produce a topologically faithful surface mesh with well controlled edge and face size as a first stage, and Almost-regular Tetrahedralization of the same prescribed mesh size as a last stage.

  8. Application of virtual surgical planning with computer assisted design and manufacturing technology to cranio-maxillofacial surgery.

    Science.gov (United States)

    Zhao, Linping; Patel, Pravin K; Cohen, Mimis

    2012-07-01

    Computer aided design and manufacturing (CAD/CAM) technology today is the standard in manufacturing industry. The application of the CAD/CAM technology, together with the emerging 3D medical images based virtual surgical planning (VSP) technology, to craniomaxillofacial reconstruction has been gaining increasing attention to reconstructive surgeons. This article illustrates the components, system and clinical management of the VSP and CAD/CAM technology including: data acquisition, virtual surgical and treatment planning, individual implant design and fabrication, and outcome assessment. It focuses primarily on the technical aspects of the VSP and CAD/CAM system to improve the predictability of the planning and outcome.

  9. Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery

    Directory of Open Access Journals (Sweden)

    Paoli Alessandro

    2011-02-01

    Full Text Available Abstract Background A precise placement of dental implants is a crucial step to optimize both prosthetic aspects and functional constraints. In this context, the use of virtual guiding systems has been recognized as a fundamental tool to control the ideal implant position. In particular, complex periodontal surgeries can be performed using preoperative planning based on CT data. The critical point of the procedure relies on the lack of accuracy in transferring CT planning information to surgical field through custom-made stereo-lithographic surgical guides. Methods In this work, a novel methodology is proposed for monitoring loss of accuracy in transferring CT dental information into periodontal surgical field. The methodology is based on integrating 3D data of anatomical (impression and cast and preoperative (radiographic template models, obtained by both CT and optical scanning processes. Results A clinical case, relative to a fully edentulous jaw patient, has been used as test case to assess the accuracy of the various steps concurring in manufacturing surgical guides. In particular, a surgical guide has been designed to place implants in the bone structure of the patient. The analysis of the results has allowed the clinician to monitor all the errors, which have been occurring step by step manufacturing the physical templates. Conclusions The use of an optical scanner, which has a higher resolution and accuracy than CT scanning, has demonstrated to be a valid support to control the precision of the various physical models adopted and to point out possible error sources. A case study regarding a fully edentulous patient has confirmed the feasibility of the proposed methodology.

  10. Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery

    Science.gov (United States)

    2011-01-01

    Background A precise placement of dental implants is a crucial step to optimize both prosthetic aspects and functional constraints. In this context, the use of virtual guiding systems has been recognized as a fundamental tool to control the ideal implant position. In particular, complex periodontal surgeries can be performed using preoperative planning based on CT data. The critical point of the procedure relies on the lack of accuracy in transferring CT planning information to surgical field through custom-made stereo-lithographic surgical guides. Methods In this work, a novel methodology is proposed for monitoring loss of accuracy in transferring CT dental information into periodontal surgical field. The methodology is based on integrating 3D data of anatomical (impression and cast) and preoperative (radiographic template) models, obtained by both CT and optical scanning processes. Results A clinical case, relative to a fully edentulous jaw patient, has been used as test case to assess the accuracy of the various steps concurring in manufacturing surgical guides. In particular, a surgical guide has been designed to place implants in the bone structure of the patient. The analysis of the results has allowed the clinician to monitor all the errors, which have been occurring step by step manufacturing the physical templates. Conclusions The use of an optical scanner, which has a higher resolution and accuracy than CT scanning, has demonstrated to be a valid support to control the precision of the various physical models adopted and to point out possible error sources. A case study regarding a fully edentulous patient has confirmed the feasibility of the proposed methodology. PMID:21338504

  11. Comparison of computer assisted surgery with conventional technique for treatment of abaxial distal phalanx fractures in horses: an in vitro study.

    Science.gov (United States)

    Rossol, Melanie; Gygax, Diego; Andritzky-Waas, Juliane; Zheng, Guoyan; Lischer, Christoph J; Zhang, Xuan; Auer, Joerg A

    2008-01-01

    To (1) evaluate and compare computer-assisted surgery (CAS) with conventional screw insertion (conventional osteosynthesis [COS]) for treatment of equine abaxial distal phalanx fractures; (2) compare planned screw position with actual postoperative position; and (3) determine preferred screw insertion direction. Experimental study. Cadaveric equine limbs (n=32). In 8 specimens each, a 4.5 mm cortex bone screw was inserted in lag fashion in dorsopalmar (plantar) direction using CAS or COS. In 2 other groups of 8, the screws were inserted in opposite direction. Precision of CAS was determined by comparison of planned and actual screw position. Preferred screw direction was also assessed for CAS and COS. In 4 of 6 direct comparisons, screw positioning was significantly better with CAS. Results of precision analysis for screw position were similar to studies published in human medicine. None of evaluated criteria identified a preferred direction for screw insertion. For abaxial fractures of the distal phalanx, superior precision in screw position is achieved with CAS technique compared with COS technique. Abaxial fractures of the distal phalanx lend themselves to computer-assisted implantation of 1 screw in a dorsopalmar (plantar) direction. Because of the complex anatomic relationships, and our results, we discourage use of COS technique for repair of this fracture type.

  12. COMPUTING

    CERN Multimedia

    I. Fisk

    2013-01-01

    Computing activity had ramped down after the completion of the reprocessing of the 2012 data and parked data, but is increasing with new simulation samples for analysis and upgrade studies. Much of the Computing effort is currently involved in activities to improve the computing system in preparation for 2015. Operations Office Since the beginning of 2013, the Computing Operations team successfully re-processed the 2012 data in record time, not only by using opportunistic resources like the San Diego Supercomputer Center which was accessible, to re-process the primary datasets HTMHT and MultiJet in Run2012D much earlier than planned. The Heavy-Ion data-taking period was successfully concluded in February collecting almost 500 T. Figure 3: Number of events per month (data) In LS1, our emphasis is to increase efficiency and flexibility of the infrastructure and operation. Computing Operations is working on separating disk and tape at the Tier-1 sites and the full implementation of the xrootd federation ...

  13. Turbinate surgery

    Science.gov (United States)

    Turbinectomy; Turbinoplasty; Turbinate reduction; Nasal airway surgery; Nasal obstruction - turbinate surgery ... There are several types of turbinate surgery: Turbinectomy: All or ... This can be done in several different ways, but sometimes a ...

  14. Bariatric Surgery

    Science.gov (United States)

    ... often. Each type of surgery has advantages and disadvantages. Bariatric Surgery Benefits Bariatric surgery can improve many ... Grants & Grant History Research Resources Research at NIDDK Technology Advancement & Transfer Meetings & Workshops Health Information Diabetes Digestive ...

  15. Lung surgery

    Science.gov (United States)

    ... are thoracotomy and video-assisted thoracoscopic surgery (VATS). Robotic surgery may also be used. Lung surgery using ... Center-Shreveport, Shreveport, LA. Review provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, ...

  16. Plastic Surgery

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Plastic Surgery KidsHealth / For Teens / Plastic Surgery What's in ... her forehead lightened with a laser? What Is Plastic Surgery? Just because the name includes the word " ...

  17. COMPUTING

    CERN Multimedia

    I. Fisk

    2010-01-01

    Introduction It has been a very active quarter in Computing with interesting progress in all areas. The activity level at the computing facilities, driven by both organised processing from data operations and user analysis, has been steadily increasing. The large-scale production of simulated events that has been progressing throughout the fall is wrapping-up and reprocessing with pile-up will continue. A large reprocessing of all the proton-proton data has just been released and another will follow shortly. The number of analysis jobs by users each day, that was already hitting the computing model expectations at the time of ICHEP, is now 33% higher. We are expecting a busy holiday break to ensure samples are ready in time for the winter conferences. Heavy Ion An activity that is still in progress is computing for the heavy-ion program. The heavy-ion events are collected without zero suppression, so the event size is much large at roughly 11 MB per event of RAW. The central collisions are more complex and...

  18. COMPUTING

    CERN Multimedia

    M. Kasemann P. McBride Edited by M-C. Sawley with contributions from: P. Kreuzer D. Bonacorsi S. Belforte F. Wuerthwein L. Bauerdick K. Lassila-Perini M-C. Sawley

    Introduction More than seventy CMS collaborators attended the Computing and Offline Workshop in San Diego, California, April 20-24th to discuss the state of readiness of software and computing for collisions. Focus and priority were given to preparations for data taking and providing room for ample dialog between groups involved in Commissioning, Data Operations, Analysis and MC Production. Throughout the workshop, aspects of software, operating procedures and issues addressing all parts of the computing model were discussed. Plans for the CMS participation in STEP’09, the combined scale testing for all four experiments due in June 2009, were refined. The article in CMS Times by Frank Wuerthwein gave a good recap of the highly collaborative atmosphere of the workshop. Many thanks to UCSD and to the organizers for taking care of this workshop, which resulted in a long list of action items and was definitely a success. A considerable amount of effort and care is invested in the estimate of the comput...

  19. [Contribution of computer-aided design for the conception of custom-made implants in Pectus Excavatum surgical treatment. Experience of the Nantes plastic surgery unit].

    Science.gov (United States)

    Tilliet Le Dentu, H; Lancien, U; Sellal, O; Duteille, F; Perrot, P

    2018-02-01

    Pectus excavatum is the most common congenital chest malformation and is a common reason for consultation in plastic surgery. Our attitude is most often a filling of the depression with a custom-made silicone prosthesis. The objective of this work was to evaluate the interest of computer-aided design (CAD) of implants compared to the conventional plaster molds method. We have collected all the cases of custom-made silicone implants to treat funnel chests in our plastic surgery department. The quality of the results was evaluated by the patient, and in a blind manner by the surgical team using photographs and standardized surveys. The pre-operative delays, the operating time and length of hospital stays, the number of surgical recoveries, and the post-operative surgical outcomes were recorded. Between 1990 and 2016, we designed 29 silicone thoracic implants in our department. Before 2012, implants were made from plaster chest molds (n=13). After this date, implants were designed by CAD (n=16). Patients rated their results as "good" or "excellent" in 77% and 86% of cases respectively in the plaster and CAD groups. The surgical team's ratings for CAD implant reconstructions were better than in the plaster group: 8.17 versus 6.96 (P=0.001). CAD implants were significantly less detectable than the plaster group implants. The operating time was reduced in the CAO group: 60.2 compared to 74.7minutes in the plaster group (P=0.04), as was the length of hospitalization: 3.5 versus 5.3 days (P=0.01). There were no significant differences between the two groups in terms of post-operative complications. The management of pectus excavatum by a custom-made silicone implant is a minimally invasive method that provides good cosmetic results. The design of these implants is facilitated and qualitatively improved by CAD. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  20. Impact of competitive flow on wall shear stress in coronary surgery: computational fluid dynamics of a LIMA-LAD model.

    Science.gov (United States)

    Nordgaard, Håvard; Swillens, Abigail; Nordhaug, Dag; Kirkeby-Garstad, Idar; Van Loo, Denis; Vitale, Nicola; Segers, Patrick; Haaverstad, Rune; Lovstakken, Lasse

    2010-12-01

    Competitive flow from native coronary vessels is considered a major factor in the failure of coronary bypass grafts. However, the pathophysiological effects are not fully understood. Low and oscillatory wall shear stress (WSS) is known to induce endothelial dysfunction and vascular disease, like atherosclerosis and intimal hyperplasia. The aim was to investigate the impact of competitive flow on WSS in mammary artery bypass grafts. Using computational fluid dynamics, WSS was calculated in a left internal mammary artery (LIMA) graft to the left anterior descending artery in a three-dimensional in vivo porcine coronary artery bypass graft model. The following conditions were investigated: high competitive flow (non-significant coronary lesion), partial competitive flow (significant coronary lesion), and no competitive flow (totally occluded coronary vessel). Time-averaged WSS of LIMA at high, partial, and no competitive flow were 0.3-0.6, 0.6-3.0, and 0.9-3.0 Pa, respectively. Further, oscillatory WSS quantified as the oscillatory shear index (OSI) ranged from (maximum OSI = 0.5 equals zero net WSS) 0.15 to 0.35, OSI similar to the no competitive flow condition. Graft flow is highly dependent on the degree of competitive flow. High competitive flow was found to produce unfavourable WSS consistent with endothelial dysfunction and subsequent graft narrowing and failure. Partial competitive flow, however, may be better tolerated as it was found to be similar to the ideal condition of no competitive flow.

  1. COMPUTING

    CERN Multimedia

    P. McBride

    It has been a very active year for the computing project with strong contributions from members of the global community. The project has focused on site preparation and Monte Carlo production. The operations group has begun processing data from P5 as part of the global data commissioning. Improvements in transfer rates and site availability have been seen as computing sites across the globe prepare for large scale production and analysis as part of CSA07. Preparations for the upcoming Computing Software and Analysis Challenge CSA07 are progressing. Ian Fisk and Neil Geddes have been appointed as coordinators for the challenge. CSA07 will include production tests of the Tier-0 production system, reprocessing at the Tier-1 sites and Monte Carlo production at the Tier-2 sites. At the same time there will be a large analysis exercise at the Tier-2 centres. Pre-production simulation of the Monte Carlo events for the challenge is beginning. Scale tests of the Tier-0 will begin in mid-July and the challenge it...

  2. COMPUTING

    CERN Multimedia

    M. Kasemann

    Introduction During the past six months, Computing participated in the STEP09 exercise, had a major involvement in the October exercise and has been working with CMS sites on improving open issues relevant for data taking. At the same time operations for MC production, real data reconstruction and re-reconstructions and data transfers at large scales were performed. STEP09 was successfully conducted in June as a joint exercise with ATLAS and the other experiments. It gave good indication about the readiness of the WLCG infrastructure with the two major LHC experiments stressing the reading, writing and processing of physics data. The October Exercise, in contrast, was conducted as an all-CMS exercise, where Physics, Computing and Offline worked on a common plan to exercise all steps to efficiently access and analyze data. As one of the major results, the CMS Tier-2s demonstrated to be fully capable for performing data analysis. In recent weeks, efforts were devoted to CMS Computing readiness. All th...

  3. COMPUTING

    CERN Multimedia

    I. Fisk

    2011-01-01

    Introduction It has been a very active quarter in Computing with interesting progress in all areas. The activity level at the computing facilities, driven by both organised processing from data operations and user analysis, has been steadily increasing. The large-scale production of simulated events that has been progressing throughout the fall is wrapping-up and reprocessing with pile-up will continue. A large reprocessing of all the proton-proton data has just been released and another will follow shortly. The number of analysis jobs by users each day, that was already hitting the computing model expectations at the time of ICHEP, is now 33% higher. We are expecting a busy holiday break to ensure samples are ready in time for the winter conferences. Heavy Ion The Tier 0 infrastructure was able to repack and promptly reconstruct heavy-ion collision data. Two copies were made of the data at CERN using a large CASTOR disk pool, and the core physics sample was replicated ...

  4. COMPUTING

    CERN Multimedia

    I. Fisk

    2012-01-01

    Introduction Computing continued with a high level of activity over the winter in preparation for conferences and the start of the 2012 run. 2012 brings new challenges with a new energy, more complex events, and the need to make the best use of the available time before the Long Shutdown. We expect to be resource constrained on all tiers of the computing system in 2012 and are working to ensure the high-priority goals of CMS are not impacted. Heavy ions After a successful 2011 heavy-ion run, the programme is moving to analysis. During the run, the CAF resources were well used for prompt analysis. Since then in 2012 on average 200 job slots have been used continuously at Vanderbilt for analysis workflows. Operations Office As of 2012, the Computing Project emphasis has moved from commissioning to operation of the various systems. This is reflected in the new organisation structure where the Facilities and Data Operations tasks have been merged into a common Operations Office, which now covers everything ...

  5. COMPUTING

    CERN Multimedia

    M. Kasemann

    CCRC’08 challenges and CSA08 During the February campaign of the Common Computing readiness challenges (CCRC’08), the CMS computing team had achieved very good results. The link between the detector site and the Tier0 was tested by gradually increasing the number of parallel transfer streams well beyond the target. Tests covered the global robustness at the Tier0, processing a massive number of very large files and with a high writing speed to tapes.  Other tests covered the links between the different Tiers of the distributed infrastructure and the pre-staging and reprocessing capacity of the Tier1’s: response time, data transfer rate and success rate for Tape to Buffer staging of files kept exclusively on Tape were measured. In all cases, coordination with the sites was efficient and no serious problem was found. These successful preparations prepared the ground for the second phase of the CCRC’08 campaign, in May. The Computing Software and Analysis challen...

  6. COMPUTING

    CERN Multimedia

    I. Fisk

    2010-01-01

    Introduction The first data taking period of November produced a first scientific paper, and this is a very satisfactory step for Computing. It also gave the invaluable opportunity to learn and debrief from this first, intense period, and make the necessary adaptations. The alarm procedures between different groups (DAQ, Physics, T0 processing, Alignment/calibration, T1 and T2 communications) have been reinforced. A major effort has also been invested into remodeling and optimizing operator tasks in all activities in Computing, in parallel with the recruitment of new Cat A operators. The teams are being completed and by mid year the new tasks will have been assigned. CRB (Computing Resource Board) The Board met twice since last CMS week. In December it reviewed the experience of the November data-taking period and could measure the positive improvements made for the site readiness. It also reviewed the policy under which Tier-2 are associated with Physics Groups. Such associations are decided twice per ye...

  7. COMPUTING

    CERN Multimedia

    M. Kasemann

    Introduction More than seventy CMS collaborators attended the Computing and Offline Workshop in San Diego, California, April 20-24th to discuss the state of readiness of software and computing for collisions. Focus and priority were given to preparations for data taking and providing room for ample dialog between groups involved in Commissioning, Data Operations, Analysis and MC Production. Throughout the workshop, aspects of software, operating procedures and issues addressing all parts of the computing model were discussed. Plans for the CMS participation in STEP’09, the combined scale testing for all four experiments due in June 2009, were refined. The article in CMS Times by Frank Wuerthwein gave a good recap of the highly collaborative atmosphere of the workshop. Many thanks to UCSD and to the organizers for taking care of this workshop, which resulted in a long list of action items and was definitely a success. A considerable amount of effort and care is invested in the estimate of the co...

  8. Use of multidetector computed tomography angiography of upper limb circulation in patients undergoing coronary artery bypass grafting surgery

    Directory of Open Access Journals (Sweden)

    Hasan B Altinsoy

    2017-01-01

    Full Text Available Objective: This study aimed to evaluate the bilateral forehand circulation using a 64-channel multidetector computed tomography (MDCT as a noninvasive method to define criteria for an upper extremity arterial anatomy and pathology prior to the use of arterial conduits. Materials and Methods: Fifty-five patients with coronary artery disease who underwent total arterial coronary artery bypass grafting (CABG were randomly selected for this prospective study. MDCT angiography was performed for 110 examinations of forearm and hand arterial anatomy. Prior to MDCT, Allen tests were performed in all patients with a normal result, except four. Thirteen patients had diabetes mellitus (DM, 8 had peripheral artery occlusive disease, and 19 had a history of smoking. Results: All arteries, including axillary, ulnar artery (UA and radial artery (RA, were clearly visualized in all patients. Upper extremity anatomical and pathological results were examined in 16 patients (29.1%. Severely calcified RA and/or UA were found in 6 patients who had a moderate renal failure. Nearly total occlusion of the RA was detected in another two patients. Focal intimal RA calcification was recorded in 1 female and 3 male patients. Ten patients who had severe calcification or intimal sclerosis of the upper extremity arteries had DM. The remaining patients had normal forehand arterial circulation. A persistent median artery with the absence of radial and ulnar arteries and a high bifurcation of RA from the brachial artery was detected as an anatomic variation in seven patients (12.7%. Conclusions: The major advantages of MDCT angiography are its non-invasiveness and the ability to detect calcific subadventitial plaques, which are difficult to diagnose using conventional angiography. MDCT may be used as a safe and non-invasive method to assess RA and UA prior to harvesting the upper limb artery. Preoperative imaging of forehand arteries is a means to avoid unnecessary forearm

  9. Clinical efficacy of computed tomography and coronectomy for prevention of postoperative inferior alveolar nerve injury occurring after impacted mandibular third molar surgery

    International Nuclear Information System (INIS)

    Hata, Tsuyoshi; Mandai, Toshiko; Ishida, Kohsei; Deguchi, Hiroyo; Hosoda, Masaru

    2012-01-01

    Our aim was to evaluate the clinical efficacy of computed tomography and coronectomy for preventing postoperative inferior alveolar nerve injury after impacted mandibular third molar surgery. Among the patients who visited Kawasaki Medical School Hospital between January 2009 and December 2010, 12 patients with high-risk signs of inferior alveolar nerve injury on panoramic imaging were examined for the extraction of impacted mandibular third molar by computed tomography (CT). CT examinations were performed in order to examine the relationship between the root apex of impacted mandibular third molar and inferior alveolar canal for 16 teeth. Based on the imaging findings, the patients were informed about treatment methods and their consent was obtained. We compared the CT and panoramic findings and discussed the relationship between the impacted third molar and the inferior alveolar nerve. Medical records were also examined for the presence of abnormal postoperative complications. Interruption of the cortical white line of the inferior alveolar canal was identified in 13 panoramic radiographs, and bending of the inferior alveolar canal was observed in 2 panoramic radiographs. CT findings indicated type 2 inferior alveolar nerve proximity in 13 teeth, and there was no proximity in 3 teeth. The observation was selected in 10 teeth showing nerve proximity in CT findings. Traditional third molar removal was performed for the 3 teeth with no nerve proximity. Coronectomy was performed in 3 teeth with nerve proximity. The clinical course was uneventful. To prevent inferior alveolar nerve injury, coronectomy may be a better means of removing the crown of an impacted third molar while leaving the roots intact, in cases where teeth might be in proximity with the inferior alveolar nerve. (author)

  10. Comparative validity and reproducibility study of various landmark-oriented reference planes in 3-dimensional computed tomographic analysis for patients receiving orthognathic surgery.

    Science.gov (United States)

    Lin, Hsiu-Hsia; Chuang, Ya-Fang; Weng, Jing-Ling; Lo, Lun-Jou

    2015-01-01

    Three-dimensional computed tomographic imaging has become popular in clinical evaluation, treatment planning, surgical simulation, and outcome assessment for maxillofacial intervention. The purposes of this study were to investigate whether there is any correlation among landmark-based horizontal reference planes and to validate the reproducibility and reliability of landmark identification. Preoperative and postoperative cone-beam computed tomographic images of patients who had undergone orthognathic surgery were collected. Landmark-oriented reference planes including the Frankfort horizontal plane (FHP) and the lateral semicircular canal plane (LSP) were established. Four FHPs were defined by selecting 3 points from the orbitale, porion, or midpoint of paired points. The LSP passed through both the lateral semicircular canal points and nasion. The distances between the maxillary or mandibular teeth and the reference planes were measured, and the differences between the 2 sides were calculated and compared. The precision in locating the landmarks was evaluated by performing repeated tests, and the intraobserver reproducibility and interobserver reliability were assessed. A total of 30 patients with facial deformity and malocclusion--10 patients with facial symmetry, 10 patients with facial asymmetry, and 10 patients with cleft lip and palate--were recruited. Comparing the differences among the 5 reference planes showed no statistically significant difference among all patient groups. Regarding intraobserver reproducibility, the mean differences in the 3 coordinates varied from 0 to 0.35 mm, with correlation coefficients between 0.96 and 1.0, showing high correlation between repeated tests. Regarding interobserver reliability, the mean differences among the 3 coordinates varied from 0 to 0.47 mm, with correlation coefficients between 0.88 and 1.0, exhibiting high correlation between the different examiners. The 5 horizontal reference planes were reliable and

  11. Comparison of traditional cardiovascular risk models and coronary atherosclerotic plaque as detected by computed tomography for prediction of acute coronary syndrome in patients with acute chest pain.

    Science.gov (United States)

    Ferencik, Maros; Schlett, Christopher L; Bamberg, Fabian; Truong, Quynh A; Nichols, John H; Pena, Antonio J; Shapiro, Michael D; Rogers, Ian S; Seneviratne, Sujith; Parry, Blair Alden; Cury, Ricardo C; Brady, Thomas J; Brown, David F; Nagurney, John T; Hoffmann, Udo

    2012-08-01

    The objective was to determine the association of four clinical risk scores and coronary plaque burden as detected by computed tomography (CT) with the outcome of acute coronary syndrome (ACS) in patients with acute chest pain. The hypothesis was that the combination of risk scores and plaque burden improved the discriminatory capacity for the diagnosis of ACS. The study was a subanalysis of the Rule Out Myocardial Infarction Using Computer-Assisted Tomography (ROMICAT) trial-a prospective observational cohort study. The authors enrolled patients presenting to the emergency department (ED) with a chief complaint of acute chest pain, inconclusive initial evaluation (negative biomarkers, nondiagnostic electrocardiogram [ECG]), and no history of coronary artery disease (CAD). Patients underwent contrast-enhanced 64-multidetector-row cardiac CT and received standard clinical care (serial ECG, cardiac biomarkers, and subsequent diagnostic testing, such as exercise treadmill testing, nuclear stress perfusion imaging, and/or invasive coronary angiography), as deemed clinically appropriate. The clinical providers were blinded to CT results. The chest pain score was calculated and the results were dichotomized to ≥10 (high-risk) and modeling was performed to examine the association of risk scores and coronary plaque burden to the outcome of ACS. Unadjusted models were individually fitted for the coronary plaque burden and for Goldman, Sanchis, TIMI, and chest pain scores. In adjusted analyses, the authors tested whether the association between risk scores and ACS persisted after controlling for the coronary plaque burden. The prognostic discriminatory capacity of the risk scores and plaque burden for ACS was assessed using c-statistics. The differences in area under the receiver-operating characteristic curve (AUC) and c-statistics were tested by performing the -2 log likelihood ratio test of nested models. A p value capacity for the diagnosis of ACS. Plaque burden was

  12. Comparison of gated blood pool SPECT and spiral multidetector computed tomography in the assessment of right ventricular functional parameters. Validation with first-pass radionuclide angiography

    International Nuclear Information System (INIS)

    Lee, Jung S.; Kim, Seong-Jang; Kim, In-Ju; Kim, Yong-Ki; Choo, Ki S.; Lee, Jun S.

    2007-01-01

    The aim of this study was to compare gated blood pool single photon emission computed tomography (SPECT) (GBPS) and multidetector row computed tomography (MDCT) for the determination of right ventricular ejection fraction (RVEF) and right ventricular volumes (RVV) and to compare first-pass radionuclide angiography (FP-RNA) as the gold standard. Twenty consecutive patients (11 men, 9 women) referred for MDCT for the evaluation of the presence of coronary artery disease underwent FP-RNA and GBPS. The mean right ventricular end-diastolic volume (EDV) calculated with GBPS revealed a statistically significant lower value than that of MDCT. The mean right ventricular end-systolic volume (ESV) calculated with GBPS was also lower than that of MDCT. A comparison of right ventricular EDV from GBPS and MDCT yielded a correlation coefficient of 0.5972. Right ventricular ESV between GBPS and MDCT showed a correlation coefficient of 0.5650. The mean RVEFs calculated with FP-RNA (39.8%±4.0%), GBPS (43.7%±6.9%), and MDCT (40.4%±7.7%) showed no statistical differences (Kruskal-Wallis statistics 4.538, P=0.1034). A comparison of RVEFs from FP-RNA and GBPS yielded a correlation coefficient of 0.7251; RVEFs between FP-RNA and MDCT showed a correlation coefficient of 0.6166 and between GBPS and MDCT showed a correlation coefficient of 0.6367. The RVEF, EDV, and ESV calculated by GBPS had good correlation with those obtained with MDCT. In addition, there were no statistical differences of RVEF calculated from FP-RNA, GBPS, and MDCT. However, with regard to RVV, EDV and ESV from GBPS revealed statistically significantly lower values than those of MDCT. Although reasonable correlations among these modalities were obtained, the agreement among these three modalities was not good enough for interchangeable use in the clinical setting. Also, these results should be confirmed in patients with cardiac diseases in future larger population-based studies. (author)

  13. THE INFLUENCE OF COMPUTER-ASSISTED SURGERY ON CLINICAL AND RADIOGRAPHIC OUTCOMES OF PERIАRTICULAR FEMUR AND TIBIA OSTEOTOMIES IN OSTEOARTHRITIC PATIENTS (REVIEW

    Directory of Open Access Journals (Sweden)

    P. G. Kochergin

    2017-01-01

    Full Text Available Nowadays the clinical application of digital technologies became a growing trend at every stage of orthopedic patient treatment: from diagnostic procedures and pre-operative planning to intra-operative control of surgical manipulations and evaluation of final results later. The aim of thi sresearch was to analyze the studies dedicated to application of computer-assisted surgery (CAS for femur and tibial osteotomies in patients with gonarthrosis. The hypothesis was that CAS improves the precision of leg alignment correction in frontal and sagittal planes that positively influencing both functional result of treatment and longevity of clinical effect. The PubMed, PubMedCentral, GoogleScholar and eLIBRARY searched for relevant studies using following key words: knee, osteoarthritis, gonarthrosis, osteotomy, CAS, navigation and its russian analogs. The majority of publications favored CAS in comparison to traditional osteotomy techniques both for leg alignment and tibial slope control. Despite generally researchers paid less attention to functional results after CASosteotomies than to precision of surgical manipulations it is possible of confirm that there is strong tendency to better knee scores after navigation while the difference is not always statistically significant. Rare publications dedicated to long term results favor CAS: 10 years survival rate is 97% that correspond to outcomes of modern total knee arthroplasty. Hence, the current literature confirms the hypothesis of our study and don’t reveal increase of complications rate associated with CAS.

  14. Anatomic variants of interest in endoscopic sinus surgery: role of computed tomography; Variantes anatomicas de interes en cirugia endoscopica nasosinusal. Papel de la tomografia computerizada

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, S.; Arenas, J.; Fernandez, F.; Gil, S.; Guirau, M. D. [Hospital General Universitario de Alicante (Spain)

    2000-07-01

    The detailed radiological study of the anatomy of the nasal cavities and paranasal sinus is essential prior to endoscopic sinus surgery since, on the one hand, it discloses the extent of the disease and, on the other hand, it aids in the detection of the numerous anatomic variants, some of which are of great interest to the endoscopic as the lack of preoperative knowledge of them may increase the risk of complications. the objective of the present report is to review these variants, stressing those that may be associated with a greater surgical risk. Although coronal computed tomography is the technique of choice for pre endoscopy examination, certain structures and anatomic variants are better viewed in axial images. These exceptions include anterior and posterior walls of the frontal sinuses, the anatomic relationships between posterior ethmoid complex and the sphenoid sinus, the relationships between the sphenoid sinus and the optic nerve, and the detection of Onodi cells. Thus, we recommend that the radiological examination include both coronal and axial images. (Author) 16 refs.

  15. COMPUTING

    CERN Multimedia

    2010-01-01

    Introduction Just two months after the “LHC First Physics” event of 30th March, the analysis of the O(200) million 7 TeV collision events in CMS accumulated during the first 60 days is well under way. The consistency of the CMS computing model has been confirmed during these first weeks of data taking. This model is based on a hierarchy of use-cases deployed between the different tiers and, in particular, the distribution of RECO data to T1s, who then serve data on request to T2s, along a topology known as “fat tree”. Indeed, during this period this model was further extended by almost full “mesh” commissioning, meaning that RECO data were shipped to T2s whenever possible, enabling additional physics analyses compared with the “fat tree” model. Computing activities at the CMS Analysis Facility (CAF) have been marked by a good time response for a load almost evenly shared between ALCA (Alignment and Calibration tasks - highest p...

  16. COMPUTING

    CERN Multimedia

    Contributions from I. Fisk

    2012-01-01

    Introduction The start of the 2012 run has been busy for Computing. We have reconstructed, archived, and served a larger sample of new data than in 2011, and we are in the process of producing an even larger new sample of simulations at 8 TeV. The running conditions and system performance are largely what was anticipated in the plan, thanks to the hard work and preparation of many people. Heavy ions Heavy Ions has been actively analysing data and preparing for conferences.  Operations Office Figure 6: Transfers from all sites in the last 90 days For ICHEP and the Upgrade efforts, we needed to produce and process record amounts of MC samples while supporting the very successful data-taking. This was a large burden, especially on the team members. Nevertheless the last three months were very successful and the total output was phenomenal, thanks to our dedicated site admins who keep the sites operational and the computing project members who spend countless hours nursing the...

  17. COMPUTING

    CERN Multimedia

    M. Kasemann

    Introduction A large fraction of the effort was focused during the last period into the preparation and monitoring of the February tests of Common VO Computing Readiness Challenge 08. CCRC08 is being run by the WLCG collaboration in two phases, between the centres and all experiments. The February test is dedicated to functionality tests, while the May challenge will consist of running at all centres and with full workflows. For this first period, a number of functionality checks of the computing power, data repositories and archives as well as network links are planned. This will help assess the reliability of the systems under a variety of loads, and identifying possible bottlenecks. Many tests are scheduled together with other VOs, allowing the full scale stress test. The data rates (writing, accessing and transfer¬ring) are being checked under a variety of loads and operating conditions, as well as the reliability and transfer rates of the links between Tier-0 and Tier-1s. In addition, the capa...

  18. COMPUTING

    CERN Multimedia

    Matthias Kasemann

    Overview The main focus during the summer was to handle data coming from the detector and to perform Monte Carlo production. The lessons learned during the CCRC and CSA08 challenges in May were addressed by dedicated PADA campaigns lead by the Integration team. Big improvements were achieved in the stability and reliability of the CMS Tier1 and Tier2 centres by regular and systematic follow-up of faults and errors with the help of the Savannah bug tracking system. In preparation for data taking the roles of a Computing Run Coordinator and regular computing shifts monitoring the services and infrastructure as well as interfacing to the data operations tasks are being defined. The shift plan until the end of 2008 is being put together. User support worked on documentation and organized several training sessions. The ECoM task force delivered the report on “Use Cases for Start-up of pp Data-Taking” with recommendations and a set of tests to be performed for trigger rates much higher than the ...

  19. COMPUTING

    CERN Multimedia

    P. MacBride

    The Computing Software and Analysis Challenge CSA07 has been the main focus of the Computing Project for the past few months. Activities began over the summer with the preparation of the Monte Carlo data sets for the challenge and tests of the new production system at the Tier-0 at CERN. The pre-challenge Monte Carlo production was done in several steps: physics generation, detector simulation, digitization, conversion to RAW format and the samples were run through the High Level Trigger (HLT). The data was then merged into three "Soups": Chowder (ALPGEN), Stew (Filtered Pythia) and Gumbo (Pythia). The challenge officially started when the first Chowder events were reconstructed on the Tier-0 on October 3rd. The data operations teams were very busy during the the challenge period. The MC production teams continued with signal production and processing while the Tier-0 and Tier-1 teams worked on splitting the Soups into Primary Data Sets (PDS), reconstruction and skimming. The storage sys...

  20. COMPUTING

    CERN Multimedia

    I. Fisk

    2013-01-01

    Computing operation has been lower as the Run 1 samples are completing and smaller samples for upgrades and preparations are ramping up. Much of the computing activity is focusing on preparations for Run 2 and improvements in data access and flexibility of using resources. Operations Office Data processing was slow in the second half of 2013 with only the legacy re-reconstruction pass of 2011 data being processed at the sites.   Figure 1: MC production and processing was more in demand with a peak of over 750 Million GEN-SIM events in a single month.   Figure 2: The transfer system worked reliably and efficiently and transferred on average close to 520 TB per week with peaks at close to 1.2 PB.   Figure 3: The volume of data moved between CMS sites in the last six months   The tape utilisation was a focus for the operation teams with frequent deletion campaigns from deprecated 7 TeV MC GEN-SIM samples to INVALID datasets, which could be cleaned up...

  1. COMPUTING

    CERN Multimedia

    I. Fisk

    2012-01-01

      Introduction Computing activity has been running at a sustained, high rate as we collect data at high luminosity, process simulation, and begin to process the parked data. The system is functional, though a number of improvements are planned during LS1. Many of the changes will impact users, we hope only in positive ways. We are trying to improve the distributed analysis tools as well as the ability to access more data samples more transparently.  Operations Office Figure 2: Number of events per month, for 2012 Since the June CMS Week, Computing Operations teams successfully completed data re-reconstruction passes and finished the CMSSW_53X MC campaign with over three billion events available in AOD format. Recorded data was successfully processed in parallel, exceeding 1.2 billion raw physics events per month for the first time in October 2012 due to the increase in data-parking rate. In parallel, large efforts were dedicated to WMAgent development and integrati...

  2. The multidetector computed tomography angiography (MDCTA) in the diagnosis of splenic artery aneurysm and pseudoaneurysm

    International Nuclear Information System (INIS)

    Saba, Luca; Mallarini, Giorgio; Anzidei, Michele; Lucatelli, Pierleone

    2011-01-01

    Splenic artery aneurysm is the most frequent visceral artery aneurysm and rupture of the aneurysm is associated with a high mortality rate. It is important to discriminate between a true aneurysm and a pseudoaneurysm that may be caused by pancreatitis, iatrogenic and postoperative causes, trauma and peptic ulcer disease. Multidetector-row CT angiography (MDCTA) allows detailed visualization of the vascular anatomy and may allow identification of aneurysms and pseudoaneurysms that affect the splenic artery. The objective of this article is to provide a review of the general characteristics of splenic artery aneurysms and pseudoaneurysms and to describe the findings of MDCTA

  3. The multidetector computed tomography angiography (MDCTA) in the diagnosis of splenic artery aneurysm and pseudoaneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Mallarini, Giorgio (Dept. of Radiology, Azienda Ospedaliero Universitaria (AOU), Cagliari (Italy)), email: lucasaba@tiscali.it; Anzidei, Michele; Lucatelli, Pierleone (Dept. of Radiological Sciences, Univ. of Rome La Sapienza, Rome (Italy))

    2011-06-15

    Splenic artery aneurysm is the most frequent visceral artery aneurysm and rupture of the aneurysm is associated with a high mortality rate. It is important to discriminate between a true aneurysm and a pseudoaneurysm that may be caused by pancreatitis, iatrogenic and postoperative causes, trauma and peptic ulcer disease. Multidetector-row CT angiography (MDCTA) allows detailed visualization of the vascular anatomy and may allow identification of aneurysms and pseudoaneurysms that affect the splenic artery. The objective of this article is to provide a review of the general characteristics of splenic artery aneurysms and pseudoaneurysms and to describe the findings of MDCTA

  4. COMPUTING

    CERN Multimedia

    I. Fisk

    2011-01-01

    Introduction The Computing Team successfully completed the storage, initial processing, and distribution for analysis of proton-proton data in 2011. There are still a variety of activities ongoing to support winter conference activities and preparations for 2012. Heavy ions The heavy-ion run for 2011 started in early November and has already demonstrated good machine performance and success of some of the more advanced workflows planned for 2011. Data collection will continue until early December. Facilities and Infrastructure Operations Operational and deployment support for WMAgent and WorkQueue+Request Manager components, routinely used in production by Data Operations, are provided. The GlideInWMS and components installation are now deployed at CERN, which is added to the GlideInWMS factory placed in the US. There has been new operational collaboration between the CERN team and the UCSD GlideIn factory operators, covering each others time zones by monitoring/debugging pilot jobs sent from the facto...

  5. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, surgery, ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, surgery, ...

  6. The usefulness of dipyridamole thallium-201 single photon emission computed tomography for predicting perioperative cardiac events in patients undergoing non-cardiac vascular surgery

    International Nuclear Information System (INIS)

    Chen Tao; Huang Gang

    2004-01-01

    The aim of this study was to evaluate the usefulness of dipyridamole Tl-201 myocardium single photon emission computed tomography (201Tl-SPECT) for predicting perioperative cardiac events in patients with arteriosclerosis obliterans (ASO) and abdominal aortic aneurysm (AAA) undergoing non-cardiac vascular surgery. Methods: Preoperative dipyridamole 201Tl-SPECT imaging in association with clinical risk assessment was performed in 224 consecutive patients (97 ASO and 127 AAA). Results: The patients were classified into three groups, including low-risk (n=173, 77%), intermediate-risk (n=39, 18%), and high-risk (n=12, 5%) groups according to the clinical risk stratification. The prevalence of reversible Tl-201 defect was significantly higher in the high-risk group than that in the low-risk group (83% vs. 14%, p<0.001). In 180 patients who underwent vascular surgery, 9 patients (5.0%) had perioperative cardiac events, including heart failure (n=l), unstable angina (n=2), and other cardiac events such as arrhythmias (n=6). The clinical variables including the clinical risk stratification did not significantly correlate with the perioperative cardiac events. In contrast, the reversible defect on 201Tl-SPECT was the only variable to predict perioperative cardiac events by a stepwise logistic regression analysis (odds ratio 7.0, 95% confidence interval l.7-28.0, p=0.007). It was also a significant predictor of perioperative cardiac events in a subgroup of low risk patients (odds ratio 11.6, 95% confidence interval 2.3-57.4, p=0.004). The sensitivity and specificity of the reversible defect for predicting perioperative cardiac events were 55.6% and 84.8% in all operated patients, and 57.1% and 89.7% in low risk patients, respectively. Conclusions: The preoperative dipyridamole 201Tl-SPECT was useful for predicting perioperative cardiac events in patients with vascular diseases, even in patients identified as having a low risk based on the clinical risk assessment. (authors)

  7. COMPUTING

    CERN Multimedia

    M. Kasemann

    CMS relies on a well functioning, distributed computing infrastructure. The Site Availability Monitoring (SAM) and the Job Robot submission have been very instrumental for site commissioning in order to increase availability of more sites such that they are available to participate in CSA07 and are ready to be used for analysis. The commissioning process has been further developed, including "lessons learned" documentation via the CMS twiki. Recently the visualization, presentation and summarizing of SAM tests for sites has been redesigned, it is now developed by the central ARDA project of WLCG. Work to test the new gLite Workload Management System was performed; a 4 times increase in throughput with respect to LCG Resource Broker is observed. CMS has designed and launched a new-generation traffic load generator called "LoadTest" to commission and to keep exercised all data transfer routes in the CMS PhE-DEx topology. Since mid-February, a transfer volume of about 12 P...

  8. The usefulness of dipyridamole thallium-201 single photon emission computed tomography for predicting perioperative cardiac events in patients undergoing non-cardiac vascular surgery

    International Nuclear Information System (INIS)

    Chen, Tao; Kuwabara, Yasuo; Tsutsui, Hiroyuki; Sasaki, Masayuki; Nakagawa, Makoto; Koga, Hirofumi; Kaneko, Kouichirou; Komori, Kimihiro; Masuda, Kouji

    2002-01-01

    The aim of this study was to evaluate the usefulness of dipyridamole Tl-201 myocardium single photon emission computed tomography ( 201 Tl-SPECT) for predicting perioperative cardiac events in patients with arteriosclerosis obliterans (ASO) and abdominal aortic aneurysm (AAA) undergoing non-cardiac vascular surgery. Preoperative dipyridamole 201 Tl-SPECT imaging in association with clinical risk assessment was performed in 224 consecutive patients (97 ASO and 127 AAA). The patients were classified into three groups, including low-risk (n=173, 77%), intermediate-risk (n=39, 18%), and high-risk (n=12, 5%) groups according to the clinical risk stratification. The prevalence of reversible Tl-201 defect was significantly higher in the high-risk group than that in the low-risk group (83% vs. 14%, p 201 Tl-SPECT was the only variable to predict perioperative cardiac events by a stepwise logistic regression analysis (odds ratio 7.0, 95% confidence interval 1.7-28.0, p=0.007). It was also a significant predictor of perioperative cardiac events in a subgroup of low risk patients (odds ratio 11.6, 95% confidence interval 2.3-57.4, p=0.004). The sensitivity and specificity of the reversible defect for predicting perioperative cardiac events were 55.6% and 84.8% in all operated patients, and 57.1% and 89.7% in low risk patients, respectively. The preoperative dipyridamole 201 Tl-SPECT was useful for predicting perioperative cardiac events in patients with vascular diseases, even in patients identified as having a low risk based on the clinical risk assessment. (author)

  9. Robotic surgery

    Science.gov (United States)

    ... with this type of surgery give it some advantages over standard endoscopic techniques. The surgeon can make ... Elsevier Saunders; 2015:chap 87. Muller CL, Fried GM. Emerging technology in surgery: Informatics, electronics, robotics. In: ...

  10. Nose Surgery

    Science.gov (United States)

    ... Patient Health Home Copyright © 2018 American Academy of Otolaryngology–Head and Neck Surgery. Reproduction or republication strictly ... Terms of Use © Copyright 2018. American Academy of Otolaryngology — Head and Neck Surgery 1650 Diagonal Rd Alexandria, ...

  11. After Surgery

    Science.gov (United States)

    ... side effects. There is usually some pain with surgery. There may also be swelling and soreness around ... the first few days, weeks, or months after surgery. Some other questions to ask are How long ...

  12. Measurements of regional cerebral blood flow (rCBF) using dynamic single-photon emission computed tomography (DSPECT): Definition of a generally acceptable normal range and follow-up checks after extracranial bypass surgery

    International Nuclear Information System (INIS)

    Kreisig, T.

    1986-01-01

    The usefulness of dynamic single-photon emission computed tomography was evaluated in 50 volunteers with unobtrusive cerebral findings, who were to provide the relevant standard values. It was found that the values measured were easily reproducible. Measurements in patients showing cerebrovascular disease that were carried out before and after extracranial bypass surgery did mostly not suggest any perceivable improvement of cerebral blood flow. In isolated cases the cerebral reserve was influenced favourably, as judged from measurements after administration of acetazolamide. (MBC) [de

  13. Análise por tomografia computadorizada do enxerto autógeno na cirurgia de "sinus lift" Computed tomography evaluation of autogenous graft in sinus lift surgery

    Directory of Open Access Journals (Sweden)

    Sérgio Aron Ajzen

    2005-02-01

    implant. All patients were submitted to computed tomography examinations prior and six months after sinus lift surgery. Fifty-three maxillary sinuses were operated and divided into three distinct groups: autogenous bone graft, autogenous bone graft in combination with platelet-rich plasma obtained by centrifugation, and autogenous bone graft in combination with platelet-rich plasma obtained by aphaeresis. RESULTS: Computed tomography demonstrated bone growth in height and width between the initial and the follow-up computed tomography scans in all three groups. However, no statistical difference was found either for bone height or width. CONCLUSION: Clinical evidence demonstrates the effectiveness of autogenous bone grafts, particularly when used in combination with bone growth factors such as platelet-rich plasma, which allow prosthetic and functional restoration of maxillofacial structures through fixation of dental implants.

  14. Thyroid Surgery

    Science.gov (United States)

    ... Hypothyroidism in Children and Adolescents Pediatric Differentiated Thyroid Cancer Thyroid Nodules in Children and Adolescents Thyroid Surgery Resources Thyroid Surgery Brochure PDF Thyroid Surgery FAQs PDF En Español Cirugia De La Tiroides El folleto de Cirugia De La Tiroides Search Thyroid ...

  15. A correlation study on the displacement of the whole breast target after breast-conserving surgery based on four-dimensional computed tomography

    International Nuclear Information System (INIS)

    Wang Wei; Li Jianbin; Wang Suzhen; Zhang Yingjie; Li Fengxiang; Xu Min; Shang Dongping

    2011-01-01

    Objective: To investigate the correlations of the whole breast displacement in different respiratory cycle during free breathing (FB) following breast-conserving surgery to the displacement of selected skin marker, nipple, and selected surgical clip based on four-dimensional computed tomography (4D-CT). Methods: Thirteen breast cancer patients who had undergone breast-conserving surgery received whole breast intensity-modulated radiotherapy (IMRT). Respiration-synchronized 4D-CT image data were gathered during FB and were exported to the Varian Eclipse treatment planning system, and the whole breast target, nipple, superior clip,and metal marker on the skin at the anterior body midline were delineated on the CT images of ten phases of the respiratory cycle by the same radiotherapist based on the same delineating criteria. The displacement distances of the delineated target in the mediolateral (x), anteroposterior (y), and superoinferior (z) axles were achieved,and the correlations of the whole breast target displacement to the displacement of the clip, nipple, and skin marker were analyzed. The ipsilateral lung was delineated on the CT images of every phase of the respiratory cycle, and the changes in ipsilateral lung volume were analyzed during the respiratory cycle relative to the displacement of the breast. Results: The maximal displacement distances of the whole breast target in the x, y, and z axles during FB were 0.71, 0.76 and 1.29 mm, respectively (F=5.755, P<0.05). There was no relationship between the three-dimensional (3D) displacement of the whole breast and the volume of the whole breast (r=-0.264, P<0.05), and there was no relationship between the displacement of the whole breast and the volume change of the ipsilateral lung (r=0.346, P<0.05). There was no significant difference among the mean target displacement distances in 3 axles,and among 2 selected successive end-inspiration (EI) phases and 3 selected successive end-expiration (EE) phases. There

  16. Aortic valve surgery - minimally invasive

    Science.gov (United States)

    ... The surgeon uses a special computer to control robotic arms during the surgery. A 3D view of ... Center-Shreveport, Shreveport, LA. Review provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, ...

  17. Mitral valve surgery - minimally invasive

    Science.gov (United States)

    ... The surgeon uses a special computer to control robotic arms during the surgery. A 3D view of ... Center-Shreveport, Shreveport, LA. Review provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, ...

  18. The Different Volume Effects of Small-Bowel Toxicity During Pelvic Irradiation Between Gynecologic Patients With and Without Abdominal Surgery: A Prospective Study With Computed Tomography-Based Dosimetry

    International Nuclear Information System (INIS)

    Huang, E.-Y.; Sung, C.-C.; Ko, S.-F.; Wang, C.-J.; Yang, Kuender D.

    2007-01-01

    Purpose: To evaluate the effect of abdominal surgery on the volume effects of small-bowel toxicity during whole-pelvic irradiation in patients with gynecologic malignancies. Methods and Materials: From May 2003 through November 2006, 80 gynecologic patients without (Group I) or with (Group II) prior abdominal surgery were analyzed. We used a computed tomography (CT) planning system to measure the small-bowel volume and dosimetry. We acquired the range of small-bowel volume in 10% (V10) to 100% (V100) of dose, at 10% intervals. The onset and grade of diarrhea during whole-pelvic irradiation were recorded as small-bowel toxicity up to 39.6 Gy in 22 fractions. Results: The volume effect of Grade 2-3 diarrhea existed from V10 to V100 in Group I patients and from V60 to V100 in Group II patients on univariate analyses. The V40 of Group I and the V100 of Group II achieved most statistical significance. The mean V40 was 281 ± 27 cm 3 and 489 ± 34 cm 3 (p 3 and 132 ± 19 cm 3 (p = 0.003). Multivariate analyses revealed that V40 (p = 0.001) and V100 (p = 0.027) were independent factors for the development of Grade 2-3 diarrhea in Groups I and II, respectively. Conclusions: Gynecologic patients without and with abdominal surgery have different volume effects on small-bowel toxicity during whole-pelvic irradiation. Low-dose volume can be used as a predictive index of Grade 2 or greater diarrhea in patients without abdominal surgery. Full-dose volume is more important than low-dose volume for Grade 2 or greater diarrhea in patients with abdominal surgery

  19. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... out more. Corrective Jaw Surgery Corrective Jaw Surgery Orthognathic surgery is performed to correct the misalignment of jaws ... out more. Corrective Jaw Surgery Corrective Jaw Surgery Orthognathic surgery is performed to correct the misalignment of jaws ...

  20. GENERAL SURGERY

    African Journals Online (AJOL)

    in the endoscopy room. GENERAL SURGERY. T du Toit, O C Buchel, S J A Smit. Department of Surgery, University of the Free State, Bloemfontein, ... The lack of video instrumentation in developing countries: Redundant fibre-optic instruments (the old. “eye scope”) are still being used. This instrument brings endoscopists ...

  1. GENERAL SURGERY

    African Journals Online (AJOL)

    mean time to first surgery post burn was 11.5 days with a median volume of 0.73 mls/kg/% ..... Mode. Mean (SD). Upper limit. 95% CI. Lower limit. 95% CI. Mode. Elective surgery .... evaluating single-unit red blood cell transfusions in reducing.

  2. Choosing surgery

    DEFF Research Database (Denmark)

    Thorstensson, Carina; Lohmander, L; Frobell, Richard

    2009-01-01

    -depth qualitative interviews were conducted with young (aged 18-35), physically active individuals with ACL rupture who were participating in a RCT comparing training and surgical reconstruction with training only. 22/34 were randomised to training only but crossed over to surgery. Of these, 11 were interviewed......ABSTRACT: BACKGROUND: The objective was to understand patients' views of treatment after acute anterior cruciate ligament (ACL) injury, and their reasons for deciding to request surgery despite consenting to participate in a randomised controlled trial (to 'cross-over'). METHODS: Thirty-four in...... before surgery, and 11 were interviewed at least 6 months after surgery. To provide additional information, 12 patients were interviewed before randomisation. Interviews were audio-recorded, transcribed and analysed using the Framework approach. RESULTS: Strong preference for surgery was commonplace...

  3. Orthognathic surgery: general considerations.

    Science.gov (United States)

    Khechoyan, David Y

    2013-08-01

    a patient's appearance and occlusal function can be improved significantly, impacting the patient's sense of self and well-being. Successful outcomes in modern orthognathic surgery rely on close collaboration between the surgeon and the orthodontist across all stages of treatment, from preoperative planning to finalization of occlusion. Virtual computer planning promotes a more accurate analysis of dentofacial deformity and preoperative planning. It is also an invaluable aid in providing comprehensive patient education. In this article, the author describes the general surgical principles that underlie orthognathic surgery, highlighting the sequence of treatment, preoperative analysis of dentofacial deformity, surgical execution of the treatment plan, and possible complications.

  4. Imaging of Acute Mesenteric Ischemia Using Multidetector CT and CT Angiography in a Porcine Model

    OpenAIRE

    Rosow, David E.; Sahani, Dushyant; Strobel, Oliver; Kalva, Sanjeeva; Mino-Kenudson, Mari; Holalkere, Nagaraj S.; Alsfasser, Guido; Saini, Sanjay; Lee, Susanna I.; Mueller, Peter R.; Castillo, Carlos Fernández-del; Warshaw, Andrew L.; Thayer, Sarah P.

    2005-01-01

    Acute mesenteric ischemia, a frequently lethal disease, requires prompt diagnosis and intervention for favorable clinical outcomes. This goal remains elusive due, in part, to lack of a noninvasive and accurate imaging study. Traditional angiography is the diagnostic gold standard but is invasive and costly. Computed tomography (CT) is readily available and noninvasive but has shown variable success in diagnosing this disease. The faster scanning time of multidetector row CT (M.D.CT) greatly f...

  5. Reverse Redistribution in Myocardial Perfusion Imaging: Revisited with 64-slice MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Kyung; Kim, Jeong Ho; Hwang, Kyung Hoon; Choi, In Suck; Choi, Soo Jin; Choe, Won Sick [Gachon University Gil Hospital, Incheon (Korea, Republic of); Yoon, Min Ki [Good Samaritan Hospital, Pohang (Korea, Republic of)

    2010-06-15

    The authors report myocardial perfusion imaging of a patient showing reverse redistribution (RR) and a 64-slice multidetector-row computed tomography (MDCT) with corresponding findings. The patient had subendocardial myocardial infarction (MI) with positive electrocardiogram (EMG) findings and elevated levels of cardiac isoenzymes. Experiencing this case emphasizes the importance of complementary correlation of a new diagnostic modality that helps us to understand the nature of RR.

  6. Polyarteritis nodosa: MDCT as a 'One-Stop Shop' Modality for Whole-Body Arterial Evaluation

    International Nuclear Information System (INIS)

    Tsai, W.-L.; Tsai, I-C.; Lee Tain; Hsieh, C.-W.

    2008-01-01

    Polyarteritis nodosa is a rare disease, which is characterized by aneurysm formation and occlusion in the arteries of multiple systems. Due to its extensive involvement, whole-body evaluation is necessary for diagnosis and treatment monitoring. We report a case of polyarteritis nodosa using multidetector-row computed tomography (MDCT) as a 'one-stop shop' modality for whole-body arterial evaluation. With precise protocol design, MDCT can be used as a reliable noninvasive modality providing comprehensive whole-body arterial evaluation.

  7. Congenital and Adquired Abnormalities of Pediatric Trachea and Main-Steam Bronchi

    International Nuclear Information System (INIS)

    Vargas Bazurto, Maria Catalina; Varon, Humberto; Perez Alvarado, Maria Carolina; Puerta Ramirez, Andres Felipe; Ruales Fierro, Franco Libardo

    2011-01-01

    Tracheobronchial tree abnormalities can be first suspected in chest radiography; nonetheless, multidetector row computed tomography imaging constitutes a complementary diagnostic alternative for the evaluation of congenital and acquired tracheobronchial tree anomalies that allows the radiologist a closer approximation toward the correct diagnosis as well as the accurate description of its morphological features and differential diagnosis. We present a review of the main tracheobronchial tree pathology.

  8. Spiral CT arthrography of the knee: technique and value in the assessment of internal derangement of the knee

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Vande B.C.; Lecouvet, F.E.; Maldague, B.; Malghem, J. [Department of Radiology, Cliniques Universitaires St. Luc, Universite Catholique de Louvain, Brussels (Belgium); Poilvache, P. [Department of Orthopedic Surgery, Cliniques Universitaires St. Luc, Universite Catholique de Louvain, Brussels (Belgium)