WorldWideScience

Sample records for surgery devices panel

  1. 75 FR 61507 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of...

    Science.gov (United States)

    2010-10-05

    ...] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of Notice... announcing an amendment to the notice of meeting of the General and Plastic Surgery Devices Panel of the..., FDA announced that a meeting of the General and Plastic Surgery Devices Panel of the Medical Devices...

  2. 78 FR 16684 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-03-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  3. 77 FR 20642 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2012-04-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  4. 75 FR 47606 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-08-06

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of... General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee scheduled for August...

  5. 76 FR 14415 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-03-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  6. 76 FR 62419 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-10-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  7. 75 FR 49940 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-08-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  8. 78 FR 30928 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-05-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  9. 76 FR 39882 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-07-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0478] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  10. 76 FR 42713 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of...

    Science.gov (United States)

    2011-07-19

    ...] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of Notice... announcing an amendment to the notice of meeting of the General and Plastic Surgery Devices Panel of the... INFORMATION: In the Federal Register of July 7, 2011, FDA announced that a meeting of the General and Plastic...

  11. 76 FR 65200 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee: Notice of...

    Science.gov (United States)

    2011-10-20

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee: Notice of... Administration (FDA) is postponing the meeting of the General and Plastic Surgery Devices Panel of the Medical...

  12. 75 FR 1395 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of...

    Science.gov (United States)

    2010-01-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2009-N-0606] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of Notice...) is announcing an amendment to the notice of a meeting of the General and Plastic Surgery Devices...

  13. Solar panel foundation device

    Energy Technology Data Exchange (ETDEWEB)

    Hawley, W.W.

    1983-03-29

    A transportable solar panel foundation device which has a bottom member, at least one upstanding side member, and an essentially open top. The side members are angled to permit nesting of a plurality of the foundation devices, and reinforcement pads are carried by the foundation device to support legs for one or more solar panels.

  14. Heart failure - surgeries and devices

    Science.gov (United States)

    ... surgery; HF - surgery; Intra-aortic balloon pumps - heart failure; IABP - heart failure; Catheter based assist devices - heart failure ... problem may cause heart failure or make heart failure worse. Heart valve surgery may be needed to repair or ...

  15. Haptic device for telerobotic surgery

    Science.gov (United States)

    Salisbury, Curt; Salisbury, Jr., J. Kenneth

    2014-12-30

    A haptic device for telerobotic surgery, including a base; a linkage system having first and second linkage members coupled to the base; a motor that provides a motor force; a transmission including first and second driving pulleys arranged such that their faces form an angle and their axes form a plane, first and second idler pulleys offset from the plane and arranged between the first and second driving pulleys such that their axes divide the angle between the first and second driving pulleys, and a cable that traverses the first and second driving pulleys and the set of idler pulleys and transfers the motor force to the linkage system; an end effector coupled to distal ends of the first and second linkage members and maneuverable relative to the base; and a controller that modulates the motor force to simulate a body part at a point portion of the end effector.

  16. 77 FR 18829 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2012-03-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0001] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory...

  17. 76 FR 71983 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-11-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory...

  18. 75 FR 57968 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-09-23

    ...] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory... committee will discuss, make recommendations, and vote on information related to the PMA for the LAP-BAND...

  19. 78 FR 21129 - Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-04-09

    ... radiofrequency band ranging between 13 megahertz to 27.12 megahertz and is intended for the treatment of medical...] Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: Orthopaedic and Rehabilitation Devices Panel of the Medical Devices...

  20. 78 FR 26786 - Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2013-05-08

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Microbiology Devices Panel of the Medical Devices Advisory Committee. General Function of the Committee: To...

  1. 76 FR 48871 - Immunology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-08-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Immunology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Immunology Devices Panel of the Medical Devices Advisory Committee. General Function of the Committee: To...

  2. 76 FR 55398 - Immunology Devices Panel of the Medical Devices Advisory Committee: Notice of Postponement of...

    Science.gov (United States)

    2011-09-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Immunology Devices Panel of the Medical Devices Advisory Committee: Notice of Postponement of Meeting AGENCY... postponing the meeting of the Immunology Devices Panel of the Medical Devices Advisory Committee scheduled...

  3. 78 FR 41937 - Joint Meeting of the Gastroenterology-Urology Panel and the Radiological Devices Panel of the...

    Science.gov (United States)

    2013-07-12

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0816] Joint Meeting of the Gastroenterology-Urology Panel and the Radiological Devices Panel of the Medical...: Gastroenterology-Urology Panel and Radiological Devices Panel of the Medical Devices Advisory Committee. General...

  4. 76 FR 18227 - Molecular and Clinical Genetics Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-04-01

    ...] Molecular and Clinical Genetics Panel of the Medical Devices Advisory Committee; Notice of Meeting... comment period for the notice announcing a meeting of the Molecular and Clinical Genetics Panel (the panel... Clinical Genetics Panel of the Medical Devices Advisory Committee, and the opening of a public docket to...

  5. 76 FR 14414 - Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-03-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES [Docket No. FDA-2011-N-0002] Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug Administration, HHS... and Drug Administration (FDA). The meeting will be open to the public. Name of Committee: Microbiology...

  6. Glaucoma Drainage Device Erosion Following Ptosis Surgery.

    Science.gov (United States)

    Bae, Steven S; Campbell, Robert J

    2017-09-01

    To highlight the potential risk of glaucoma drainage device erosion following ptosis surgery. Case report. A 71-year-old man underwent uncomplicated superotemporal Ahmed glaucoma valve implantation in the left eye in 2008. Approximately 8 years later, the patient underwent bilateral ptosis repair, which successfully raised the upper eyelid position. Three months postoperatively, the patient's glaucoma drainage implant tube eroded through the corneal graft tissue and overlying conjunctiva to become exposed. A graft revision surgery was successfully performed with no further complications. Caution and conservative lid elevation may be warranted when performing ptosis repair in patients with a glaucoma drainage implant, and patients with a glaucoma implant undergoing ptosis surgery should be followed closely for signs of tube erosion.

  7. 78 FR 27971 - Dental Products Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2013-05-13

    ...] Dental Products Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Dental Products Panel of the Medical Devices Advisory Committee. General Function of the Committee: To... regulatory classification for dental devices known as Endosseous Dental Implants (Blade-form), one of the...

  8. Silver Nanoparticles in Alveolar Bone Surgery Devices

    Directory of Open Access Journals (Sweden)

    Stefano Sivolella

    2012-01-01

    Full Text Available Silver (Ag ions have well-known antimicrobial properties and have been applied as nanostrategies in many medical and surgical fields, including dentistry. The use of silver nanoparticles (Ag NPs may be an option for reducing bacterial adhesion to dental implant surfaces and preventing biofilm formation, containing the risk of peri-implant infections. Modifying the structure or surface of bone grafts and membranes with Ag NPs may also prevent the risk of contamination and infection that are common when alveolar bone augmentation techniques are used. On the other hand, Ag NPs have revealed some toxic effects on cells in vitro and in vivo in animal studies. In this setting, the aim of the present paper is to summarize the principle behind Ag NP-based devices and their clinical applications in alveolar bone and dental implant surgery.

  9. Expert panel on weight loss surgery: executive report update.

    Science.gov (United States)

    Blackburn, George L; Hutter, Matthew M; Harvey, Alan M; Apovian, Caroline M; Boulton, Hannah R W; Cummings, Susan; Fallon, John A; Greenberg, Isaac; Jiser, Michael E; Jones, Daniel B; Jones, Stephanie B; Kaplan, Lee M; Kelly, John J; Kruger, Rayford S; Lautz, David B; Lenders, Carine M; Lonigro, Robert; Luce, Helen; McNamara, Anne; Mulligan, Ann T; Paasche-Orlow, Michael K; Perna, Frank M; Pratt, Janey S A; Riley, Stancel M; Robinson, Malcolm K; Romanelli, John R; Saltzman, Edward; Schumann, Roman; Shikora, Scott A; Snow, Roger L; Sogg, Stephanie; Sullivan, Mary A; Tarnoff, Michael; Thompson, Christopher C; Wee, Christina C; Ridley, Nancy; Auerbach, John; Hu, Frank B; Kirle, Leslie; Buckley, Rita B; Annas, Catherine L

    2009-05-01

    Rapid shifts in the demographics and techniques of weight loss surgery (WLS) have led to new issues, new data, new concerns, and new challenges. In 2004, this journal published comprehensive evidence-based guidelines on WLS. In this issue, we've updated those guidelines to assure patient safety in this fast-changing field. WLS involves a uniquely vulnerable population in need of specialized resources and ongoing multidisciplinary care. Timely best-practice updates are required to identify new risks, develop strategies to address them, and optimize treatment. Findings in these reports are based on a comprehensive review of the most current literature on WLS; they directly link patient safety to methods for setting evidence-based guidelines developed from peer-reviewed scientific publications. Among other outcomes, these reports show that WLS reduces chronic disease risk factors, improves health, and confers a survival benefit on those who undergo it. The literature also shows that laparoscopy has displaced open surgery as the predominant approach; that government agencies and insurers only reimburse procedures performed at accredited WLS centers; that best practice care requires close collaboration between members of a multidisciplinary team; and that new and existing facilities require wide-ranging changes to accommodate growing numbers of severely obese patients. More than 100 specialists from across the state of Massachusetts and across the many disciplines involved in WLS came together to develop these new standards. We expect them to have far-reaching effects of the development of health care policy and the practice of WLS.

  10. 75 FR 70112 - Medical Devices; General and Plastic Surgery Devices; Classification of Non-Powered Suction...

    Science.gov (United States)

    2010-11-17

    .... FDA-2010-N-0513] Medical Devices; General and Plastic Surgery Devices; Classification of Non-Powered... risks. Adverse tissue reaction Material degradation Improper function of suction apparatus (e.g., reflux.... Material degradation Section 8. Stability and Shelf Life. [[Page 70113

  11. 75 FR 68972 - Medical Devices; General and Plastic Surgery Devices; Classification of Tissue Adhesive With...

    Science.gov (United States)

    2010-11-10

    .... FDA-2010-N-0512] Medical Devices; General and Plastic Surgery Devices; Classification of Tissue... running to unintended areas, etc. B. Wound dehiscence C. Adverse tissue reaction and chemical burns D..., Clinical Studies, Labeling. Adverse tissue reaction and chemical Biocompatibility Animal burns. Testing...

  12. Re-active Passive (RAP) Devices for Control of Noise Transmission through a Panel

    Science.gov (United States)

    Carneal, James P.; Giovanardi, Marco; Fuller, Chris R.; Palumbo, Daniel L.

    2008-01-01

    Re-Active Passive (RAP) devices have been developed to control low frequency (transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The RAP device uses passive constrained layer damping to cover the relatively high frequency range (>200 Hz), reactive distributed vibration absorber) to cover the medium frequency range (75 to 250 Hz), and active control for controlling low frequencies (transmission through a panel mounted in a transmission loss test facility. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three RAP devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 grams to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.

  13. Re-Active Passive devices for control of noise transmission through a panel

    Science.gov (United States)

    Carneal, James P.; Giovanardi, Marco; Fuller, Chris R.; Palumbo, Dan

    2008-01-01

    Re-Active Passive devices have been developed to control low-frequency (transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The Re-Active Passive device uses passive constrained layer damping to cover relatively high-frequency range (>150 Hz), reactive distributed vibration absorber to cover the medium-frequency range (50-200 Hz), and active control for controlling low frequencies (transmission through a panel mounted in the Transmission Loss Test Facility at Virginia Tech. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three Re-Active Passive devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 g to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.

  14. A 3-DOF haptic master device for minimally invasive surgery

    Science.gov (United States)

    Nguyen, Phuong-Bac; Oh, Jong-Seok; Choi, Seung-Bok

    2012-04-01

    This paper introduces a novel 3-DOF haptic master device for minimally invasive surgery featuring magneto-rheological (MR) fluid. It consists of three rotational motions. These motions are constituted by two bi-directional MR (BMR) plus one conventional MR brakes. The BMR brake used in the system possesses a salient advantage that its range of braking torque varies from negative to positive values. Therefore, the device is expected to be able sense in a wide environment from very soft tissues to bones. In this paper, overall of the design of the device is presented from idea, modeling, optimal design, manufacturing to control of the device. Moreover, experimental investigation is undertaken to validate the effectiveness of the device.

  15. 76 FR 6623 - Molecular and Clinical Genetics Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-02-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0066] Molecular and Clinical Genetics Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Molecular and Clinical Genetics Panel of the Medical Devices Advisory...

  16. 76 FR 36548 - Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-06-22

    ... information related to the humanitarian device exemption for the Berlin Heart EXCOR Pediatric Ventricular Assist Device (VAD) sponsored by Berlin Heart, Inc. The Berlin Heart EXCOR Pediatric VAD device is a..., please contact AnnMarie Williams, Conference Management Staff, at 301-796-5966, at least 7 days in...

  17. 78 FR 49272 - Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2013-08-13

    ... into two types: (1) Devices that provide automatic chest compressions at a fixed compression rate and... circuit is comprised of multiple device types, including, but not limited to, an oxygenator, blood pump... submit a brief statement of the general nature of the evidence or arguments they wish to present, the...

  18. Safety syringes and anti-needlestick devices in orthopaedic surgery.

    Science.gov (United States)

    Sibbitt, Wilmer L; Band, Philip A; Kettwich, Lawrence G; Sibbitt, Cristina R; Sibbitt, Lori J; Bankhurst, Arthur D

    2011-09-07

    The American Academy of Orthopaedic Surgery (AAOS), The Joint Commission, the Occupational Safety and Health Administration (OSHA), and the Needlestick Safety and Prevention Act encourage the integration of safety-engineered devices to prevent needlestick injuries to health-care workers and patients. We hypothesized that safety syringes and needles could be used in outpatient orthopaedic injection and aspiration procedures. The study investigated the orthopaedic uses and procedural idiosyncrasies of safety-engineered devices, including (1) four safety needles (Eclipse, SafetyGlide, SurGuard, and Magellan), (2) a mechanical safety syringe (RPD), (3) two automatic retractable syringes (Integra, VanishPoint), (4) three manual retractable syringes (Procedur-SF, Baksnap, Invirosnap), and (5) three shielded syringes (Safety-Lok, Monoject, and Digitally Activated Shielded [DAS] Syringe). The devices were first tested ex vivo, and then 1300 devices were used for 425 subjects undergoing outpatient arthrocentesis, intra-articular injections, local anesthesia, aspiration biopsy, and ultrasound-guided procedures. During the clinical observation, there were no accidental needlesticks (0 needlesticks per 1300 devices). Safety needles could be successfully used on a Luer syringe but were limited to ≤1.5 in (≤3.81 cm) in length and the shield could interfere with sonography. The mechanical safety syringes functioned well in all orthopaedic procedures. Automatic retractable syringes were too small for arthrocentesis of the knee, and the plunger blew out and prematurely collapsed with high-pressure injections. The manual retractable syringes and shielded syringes could be used with conventional needles for most orthopaedic procedures. The most effective and reliable safety devices for orthopaedic syringe procedures are shielded safety needles, mechanical syringes, manual retractable syringes, and shielded syringes, but not automatic retractable syringes. Even when adopting

  19. 78 FR 25747 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-05-02

    ... Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, MD... as catheters, cannulae or hollow needles. Chronic hemodialysis catheters are soft, blunt-tipped...

  20. Pilot for the Australian Breast Device Registry (ABDR): a national opt-out clinical quality registry for breast device surgery.

    Science.gov (United States)

    Hopper, Ingrid; Best, Renee L; McNeil, John J; Mulvany, Catherine M; Moore, Colin C M; Elder, Elisabeth; Pase, Marie; Cooter, Rodney D; Evans, Sue M

    2017-12-28

    To establish a pilot clinical quality registry (CQR) to monitor the quality of care and device performance for breast device surgery in Australia. All patients having breast device surgery from contributing hospitals in Australia. A literature review was performed which identified quality indicators for breast device surgery. A pilot CQR was established in 2011 to capture prospective data on breast device surgery. An interim Steering Committee and Management Committee were established to provide clinical governance, and guide quality indicator selection. The registry's minimum dataset was formulated in consultation with stakeholder groups; potential quality indicators were assessed in terms of (1) importance and relevance, (2) usability, (3) feasibility to collect and (4) scientific validity. Data collection was by a two-sided paper-based form with manual data entry. Seven sites were recruited, including one public hospital, four private hospitals and two day surgeries. Patients were recruited and opt-out consent used. The pilot breast device registry provides high-quality population-based data. It provides a model for developing a national CQR for breast devices; its minimum dataset and quality indicators reflect the opinions of the broad range of stakeholders. It is easily scalable, and has formed the basis for other international surgical groups establishing similar registries. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Designing innovative retractors and devices to facilitate mitral valve repair surgery

    OpenAIRE

    Okamoto, Kazuma; Yozu, Ryohei

    2015-01-01

    Various devices have been developed to facilitate mitral valve surgery, including those that improve mitral valve exposure and assist surgeons with associated procedures. Choosing appropriate supporting devices when performing minimally invasive mitral valve surgery (MIMVS) through a minithoracotomy with endoscopic assistance is critical. Depending on the surgeon’s preference, trans-thoracic or trans-working-port left atrial retractors can be utilized. Although the trans-thoracic retractors p...

  2. Process and a device for manufacturing a composite building panel for use in a building structure cladding system

    Energy Technology Data Exchange (ETDEWEB)

    Tetu, B

    1991-06-11

    A process and device are disclosed for manufacturing a composite panel used for cladding a building. The panel comprises a facing layer made from a plurality of facing elements, such as brick slices, retained in a spaced-apart relationship, and magnetically attractible particulate material disposed between the facing elements to imitate mortar. A rigid backing layer is provided, spaced from the spacing layer, and the space between the facing and the backing layers is filled with an insulation/bonding layer, made of urethane foam. The device for manufacturing the panel comprises a facing element holder in the form of a structure with a plurality of recesses for receiving facing elements, also including spacers between the recesses in order to retain the facing elements in a spaced-apart relationship. Ceramic magnets are provided on the spacers for temporarily retaining the particulate material against gravity until the insulation/bonding layer is built which retains all the panel elements together. The invention enables manufacture of non-planar panels, such as those used on corners of buildings, thereby eliminating the need for a corner joint. 9 figs.

  3. Conjunctival erosion after glaucoma drainage device surgery: A feasible option

    OpenAIRE

    Dubey, Suneeta; Prasanth, Baswati; Acharya, Manisha C; Narula, Ritesh

    2013-01-01

    Glaucoma drainage devices (GDDs) have been used in the management of complicated glaucomas. GDDs are associated with various complications such as tube migration, tube or plate exposure or extrusion, ocular motility disturbance and infection. Erosion of conjunctiva and exposure of the GDD remains a risk factor for the development of endophthalmitis. A wide range of materials have been used for this purpose, including sclera, dura, pericardium, fascia lata and cornea. However, there is no evid...

  4. Management of antithrombotic therapy during cardiac implantable device surgery.

    Science.gov (United States)

    AlTurki, Ahmed; Proietti, Riccardo; Birnie, David H; Essebag, Vidal

    2016-06-01

    Anticoagulants are commonly used drugs that are frequently encountered during device placement. Deciding when to halt or continue the use of anticoagulants is a balance between the risks of thromboembolism versus bleeding. Patients taking warfarin with a high risk of thromboembolism should continue to take their warfarin without interruption during device placement while ensuring their international normalized ratio remains below 3. For patients who are taking warfarin and have low risk of thromboembolism, either interrupted or continued warfarin may be used, with no evidence to clearly support either strategy. There is little evidence to support continuing direct acting oral anticoagulants (DOACs) for device implantation. The timing of halting these medications depends largely on renal function. If bleeding occurs, warfarin׳s anticoagulation effect is reversible with vitamin K and activated prothrombin complex concentrate. There are no DOAC reversal agents currently available, but some are under development. Regarding antiplatelet agents, aspirin alone can be safely continued while clopidogrel alone may also be continued, but with a slightly higher bleeding risk. Dual antiplatelet therapy for bare-metal stent/drug-eluting stent implanted within 4 weeks/6 months, respectively, should be continued due to high risk of stent thrombosis; however, if they are implanted after this period, then clopidogrel can be halted 5 days before the procedure and resumed soon after, while aspirin is continued. If the patient is taking both aspirin and warfarin, aspirin should be halted 5 days prior to the procedure, while warfarin is continued.

  5. Predictive Factors for Patients Undergoing ASD Device Occlusion Who "Crossover" to Surgery.

    Science.gov (United States)

    Mulukutla, Venkatachalam; Qureshi, Athar M; Pignatelli, Ricardo; Ing, Frank F

    2018-03-01

    The aim of this study was to define characteristics of those patients who are referred for device closure of an Atrial septal defect (ASD), but identified to "crossover" surgery. All patients who underwent surgical and device (Amplatzer or Helex occluder) closures of secundum ASDs from 2001 to 2010 were reviewed and organized into three groups: surgical closure, device closure, and "crossover" group. 369 patients underwent ASD closure (265 device, 104 surgical). 42 of the 265 patients referred for device closure "crossed over" to the surgical group at various stages of the catheterization procedure. The device group had defect size measuring 14.2 mm (mean) and an ASD index (Defect Size (mm)/BSA) of 14.0 compared to the corresponding values in the surgical group (20.1 mm, ASD index 25.9) (P ASD index) (P ASD index of 14.7 compared with the crossover group ASD index of 23.8 (P ASD index greater than 23.7 had a 90% specificity in "crossing over" to surgery. The crossover and surgical groups had statistically larger ASD defect size indexes compared with the device group. Deficient rim in the posterior/inferior rim is associated with a large ASD size index which is a predictive factor for crossing over to surgery. Catheterization did not negatively impact surgical results in the "crossover" group.

  6. Control device for automatic orientation of a solar panel based on a microcontroller (PIC16f628a)

    Science.gov (United States)

    Rezoug, M. R.; Krama, A.

    2016-07-01

    This work proposes a control device for autonomous solar tracker based on one axis, It consists of two main parts; the control part which is based on "the PIC16f628a"; it has the role of controlling, measuring and plotting responses. The second part is a mechanical device, which has the role of making the solar panel follows the day-night change of the sun throughout the year. Both parties are established to improve energy generation of the photovoltaic panels. In this paper, we will explain the main operating principles of our system. Also, we will provide experimental results which demonstrate the good performance and the efficiency of this system. This innovation is different from what has been proposed in previous studies. The important points of this system are maximum output energy and minimum energy consumption of solar tracker, its cost is relatively low with simplicity in implementation. The average power increase produced by using the tracking system for a particular day, is over 30 % compared with the static panel.

  7. Conjunctival erosion after glaucoma drainage device surgery: A feasible option

    Directory of Open Access Journals (Sweden)

    Suneeta Dubey

    2013-01-01

    Full Text Available Glaucoma drainage devices (GDDs have been used in the management of complicated glaucomas. GDDs are associated with various complications such as tube migration, tube or plate exposure or extrusion, ocular motility disturbance and infection. Erosion of conjunctiva and exposure of the GDD remains a risk factor for the development of endophthalmitis. A wide range of materials have been used for this purpose, including sclera, dura, pericardium, fascia lata and cornea. However, there is no evidence to prove that any of these methods is superior to another for providing tectonic durability in the long term. In this report, we present a case of neovascular glaucoma, who developed conjunctival melting over the tube of an Ahmed Glaucoma Valve implant and was successfully managed with Cap Doxycycline.

  8. Conjunctival erosion after glaucoma drainage device surgery: a feasible option.

    Science.gov (United States)

    Dubey, Suneeta; Prasanth, Baswati; Acharya, Manisha C; Narula, Ritesh

    2013-07-01

    Glaucoma drainage devices (GDDs) have been used in the management of complicated glaucomas. GDDs are associated with various complications such as tube migration, tube or plate exposure or extrusion, ocular motility disturbance and infection. Erosion of conjunctiva and exposure of the GDD remains a risk factor for the development of endophthalmitis. A wide range of materials have been used for this purpose, including sclera, dura, pericardium, fascia lata and cornea. However, there is no evidence to prove that any of these methods is superior to another for providing tectonic durability in the long term. In this report, we present a case of neovascular glaucoma, who developed conjunctival melting over the tube of an Ahmed Glaucoma Valve implant and was successfully managed with Cap Doxycycline.

  9. 76 FR 43119 - Medical Devices; General and Plastic Surgery Devices; Classification of the Focused Ultrasound...

    Science.gov (United States)

    2011-07-20

    ... type of device must submit to FDA a premarket notification, prior to marketing the device, which... Orders 12866 and 13563 direct Agencies to assess all costs and benefits of available regulatory... (including potential economic, environmental, public health and safety, and other advantages; distributive...

  10. Recommendations for radioembolisation after liver surgery using yttrium-90 resin microspheres based on a survey of an international expert panel

    Energy Technology Data Exchange (ETDEWEB)

    Samim, Morsal [University Medical Center Utrecht, Department of Surgery, Utrecht (Netherlands); University Medical Center Utrecht, Department of Radiology and Nuclear Medicine, Utrecht (Netherlands); Veenendaal, Linde M. van; Braat, Manon N.G.J.A.; Hoven, Andor F. van den; Bosch, Maurice A.A.J. van den; Lam, Marnix G.E.H. [University Medical Center Utrecht, Department of Radiology and Nuclear Medicine, Utrecht (Netherlands); Hillegersberg, Richard van [University Medical Center Utrecht, Department of Surgery, Utrecht (Netherlands); Sangro, Bruno [Clinica Universidad de Navarra-IDISNA and CIBEREHD, Liver Unit, Pamplona (Spain); Kao, Yung Hsiang [Cabrini Hospital, Department of Nuclear Medicine, Melbourne (Australia); Liu, Dave [Vancouver General Hospital, University of British Columbia, Department of Radiology, Vancouver, British Columbia (Canada); Louie, John D.; Sze, Daniel Y. [Stanford University Medical Center, Division of Interventional Radiology, Stanford (United States); Rose, Steven C. [University of California, Department of Radiology, San Diego (United States); Brown, Daniel B. [Vanderbilt University, Medical Center North, Department of Radiology, Nashville (United States); Ahmadzadehfar, Hojjat [University Hospital Bonn, Department of Nuclear Medicine, Bonn (Germany); Kim, Edward [Icahn School of Medicine at Mount Sinai, Division of Vascular and Interventional Radiology, New York (United States)

    2017-12-15

    Guidelines on how to adjust activity in patients with a history of liver surgery who are undergoing yttrium-90 radioembolisation ({sup 90}Y-RE) are lacking. The aim was to study the variability in activity prescription in these patients, between centres with extensive experience using resin microspheres {sup 90}Y-RE, and to draw recommendations on activity prescription based on an expert consensus. The variability in activity prescription between centres was investigated by a survey of international experts in the field of {sup 90}Y-RE. Six representative post-surgical patients (i.e. comparable activity prescription, different outcome) were selected. Information on patients' disease characteristics and data needed for activity calculation was presented to the expert panel. Reported was the used method for activity prescription and whether, how and why activity reduction was found indicated. Ten experts took part in the survey. Recommendations on activity reduction were highly variable between the expert panel. The median intra-patient range was 44 Gy (range 18-55 Gy). Reductions in prescribed activity were recommended in 68% of the cases. In consensus, a maximum D{sub Target} of 50 Gy was recommended. With a current lack of guidelines, large variability in activity prescription in post-surgical patients undergoing {sup 90}Y-RE exists. In consensus, D{sub Target} ≤50 Gy is recommended. (orig.)

  11. Recommendations for radioembolisation after liver surgery using yttrium-90 resin microspheres based on a survey of an international expert panel

    International Nuclear Information System (INIS)

    Samim, Morsal; Veenendaal, Linde M. van; Braat, Manon N.G.J.A.; Hoven, Andor F. van den; Bosch, Maurice A.A.J. van den; Lam, Marnix G.E.H.; Hillegersberg, Richard van; Sangro, Bruno; Kao, Yung Hsiang; Liu, Dave; Louie, John D.; Sze, Daniel Y.; Rose, Steven C.; Brown, Daniel B.; Ahmadzadehfar, Hojjat; Kim, Edward

    2017-01-01

    Guidelines on how to adjust activity in patients with a history of liver surgery who are undergoing yttrium-90 radioembolisation ( 90 Y-RE) are lacking. The aim was to study the variability in activity prescription in these patients, between centres with extensive experience using resin microspheres 90 Y-RE, and to draw recommendations on activity prescription based on an expert consensus. The variability in activity prescription between centres was investigated by a survey of international experts in the field of 90 Y-RE. Six representative post-surgical patients (i.e. comparable activity prescription, different outcome) were selected. Information on patients' disease characteristics and data needed for activity calculation was presented to the expert panel. Reported was the used method for activity prescription and whether, how and why activity reduction was found indicated. Ten experts took part in the survey. Recommendations on activity reduction were highly variable between the expert panel. The median intra-patient range was 44 Gy (range 18-55 Gy). Reductions in prescribed activity were recommended in 68% of the cases. In consensus, a maximum D Target of 50 Gy was recommended. With a current lack of guidelines, large variability in activity prescription in post-surgical patients undergoing 90 Y-RE exists. In consensus, D Target ≤50 Gy is recommended. (orig.)

  12. Human health and ecological toxicity potentials due to heavy metal content in waste electronic devices with flat panel displays

    International Nuclear Information System (INIS)

    Lim, Seong-Rin; Schoenung, Julie M.

    2010-01-01

    Display devices such as cathode-ray tube (CRT) televisions and computer monitors are known to contain toxic substances and have consequently been banned from disposal in landfills in the State of California and elsewhere. New types of flat panel display (FPD) devices, millions of which are now purchased each year, also contain toxic substances, but have not previously been systematically studied and compared to assess the potential impact that could result from their ultimate disposal. In the current work, the focus is on the evaluation of end-of-life toxicity potential from the heavy metal content in select FPD devices with the intent to inform material selection and design-for-environment (DfE) decisions. Specifically, the metals antimony, arsenic, barium, beryllium, cadmium, chromium, cobalt, copper, lead, mercury, molybdenum, nickel, selenium, silver, vanadium, and zinc in plasma TVs, LCD (liquid crystal display) TVs, LCD computer monitors and laptop computers are considered. The human health and ecotoxicity potentials are evaluated through a life cycle assessment perspective by combining data on the respective heavy metal contents, the characterization factors in the U.S. EPA Tool for the Reduction and Assessment of Chemical and other environmental Impacts (TRACI), and a pathway and impact model. Principal contributors to the toxicity potentials are lead, arsenic, copper, and mercury. Although the heavy metal content in newer flat panel display devices creates less human health toxicity potential than that in CRTs, for ecological toxicity, the new devices are worse, especially because of the mercury in LCD TVs and the copper in plasma TVs.

  13. 76 FR 20840 - Medical Devices; General and Plastic Surgery Devices; Classification of the Low Level Laser...

    Science.gov (United States)

    2011-04-14

    ... looking directly at the laser beam and the wearing of appropriate laser safety eyewear by both the user...). The special control for this device is the FDA guidance document entitled ``Guidance for Industry and...

  14. 76 FR 22805 - Medical Devices; Reclassification of the Topical Oxygen Chamber for Extremities

    Science.gov (United States)

    2011-04-25

    ... 1976 Amendments (Pub. L. 94-295), the SMDA (Pub. L. 101-629), and the FDAMA (Pub. L. 105-115... Plastic Surgery Devices Panel (GPS Panel) for their recommendation on the requested reclassification. At a public meeting on November 17, 1998, the GPS Panel recommended that the device be retained in class III...

  15. 76 FR 6551 - Medical Devices; General and Plastic Surgery Devices; Classification of Contact Cooling System...

    Science.gov (United States)

    2011-02-07

    ... (classes) of devices, depending on the regulatory controls needed to provide reasonable assurance of their... addressed by adequate bench testing demonstrating that the feedback controls for temperature/ cooling are functional and do maintain target temperature within the stated value. Proper function of mechanical controls...

  16. Embedded nonvolatile memory devices with various silicon nitride energy band gaps on glass used for flat panel display applications

    International Nuclear Information System (INIS)

    Son, Dang Ngoc; Van Duy, Nguyen; Jung, Sungwook; Yi, Junsin

    2010-01-01

    Nonvolatile memory (NVM) devices with a nitride–nitride–oxynitride stack structure on a rough poly-silicon (poly-Si) surface were fabricated using a low-temperature poly-Si (LTPS) thin film transistor technology on glass substrates for application of flat panel display (FPD). The plasma-assisted oxidation/nitridation method is used to form a uniform oxynitride with an ultrathin tunneling layer on a rough LTPS surface. The NVMs, using a Si-rich silicon nitride film as a charge-trapping layer, were proposed as one of the solutions for the improvement of device performance such as the program/erase speed, the memory window and the charge retention characteristics. To further improve the vertical scaling and charge retention characteristics of NVM devices, the high-κ high-density N-rich SiN x films are used as a blocking layer. The fabricated NVM devices have outstanding electrical properties, such as a low threshold voltage, a high ON/OFF current ratio, a low subthreshold swing, a low operating voltage of less than ±9 V and a large memory window of 3.7 V, which remained about 1.9 V over a period of 10 years. These characteristics are suitable for electrical switching and data storage with in FPD application

  17. Management of severe ischemic cardiomyopathy: left ventricular assist device as destination therapy versus conventional bypass and mitral valve surgery.

    Science.gov (United States)

    Maltais, Simon; Tchantchaleishvili, Vahtang; Schaff, Hartzell V; Daly, Richard C; Suri, Rakesh M; Dearani, Joseph A; Topilsky, Yan; Stulak, John M; Joyce, Lyle D; Park, Soon J

    2014-04-01

    Patients with severe ischemic cardiomyopathy (left ventricular ejection fraction assist device as destination therapy is reserved for patients who are too high risk for conventional surgery. We evaluated our outcomes with conventional surgery within this population and the comparative effectiveness of these 2 therapies. We identified patients who underwent conventional surgery or left ventricular assist device as destination therapy for severe ischemic cardiomyopathy (left ventricular ejection fraction assist device as destination therapy. We compared baseline patient characteristics and outcomes in terms of end-organ function and survival. A total of 88 patients were identified; 55 patients underwent conventional surgery (63%), and 33 patients (37%) received a left ventricular assist device as destination therapy. Patients who received left ventricular assist device as destination therapy had the increased prevalence of renal failure, inotrope dependency, and intra-aortic balloon support. Patients undergoing conventional surgery required longer ventilatory support, and patients receiving a left ventricular assist device required more reoperation for bleeding. Mortality rates were similar between the 2 groups at 30 days (7% in the conventional surgery group vs 3% in the left ventricular assist device as destination therapy group, P = .65) and at 1 year (22% in the conventional surgery group vs 15% in the left ventricular assist device as destination therapy group, P = .58). There was a trend toward improved survival in patients receiving a left ventricular assist device compared with the propensity-matched groups at 1 year (94% vs 71%, P = .171). The operative mortality and early survival after conventional surgery seem to be acceptable. For inoperable or prohibitive-risk patients, left ventricular assist device as destination therapy can be offered with similar outcomes. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby

  18. [Surgery guided by customized devices: reconstruction with a free fibula flap].

    Science.gov (United States)

    Schouman, T; Bertolus, C; Chaine, C; Ceccaldi, J; Goudot, P

    2014-02-01

    The reconstruction of jaws with a free fibula flap can be anticipated virtually. The simulation can be transferred to the operating theater using customized devices obtained from computer-assisted design and manufacturing in a complete digital workflow. Several alternatives are available, from cutting guides to customized titanium osteosynthesis plates, to obtain the best accuracy and reproducibility of reconstruction. Moreover, these new processes allow integrating prosthetic planning concomitantly with reconstruction. We present the virtual three-dimensional planning method for jaw reconstruction with a free fibula flap and the various alternatives of surgery guided by customized devices provided by this planning. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  19. Cone-beam CT with a flat-panel detector: From image science to image-guided surgery

    International Nuclear Information System (INIS)

    Siewerdsen, Jeffrey H.

    2011-01-01

    The development of large-area flat-panel X-ray detectors (FPDs) has spurred investigation in a spectrum of advanced medical imaging applications, including tomosynthesis and cone-beam CT (CBCT). Recent research has extended image quality metrics and theoretical models to such applications, providing a quantitative foundation for the assessment of imaging performance as well as a general framework for the design, optimization, and translation of such technologies to new applications. For example, cascaded systems models of the Fourier domain metrics, such as noise-equivalent quanta (NEQ), have been extended to these modalities to describe the propagation of signal and noise through the image acquisition and reconstruction chain and to quantify the factors that govern spatial resolution, image noise, and detectability. Moreover, such models have demonstrated basic agreement with human observer performance for a broad range of imaging conditions and imaging tasks. These developments in image science have formed a foundation for the knowledgeable development and translation of CBCT to new applications in image-guided interventions-for example, CBCT implemented on a mobile surgical C-arm for intraoperative 3D imaging. The ability to acquire high-quality 3D images on demand during surgical intervention overcomes conventional limitations of surgical guidance in the context of preoperative images alone. A prototype mobile C-arm developed in academic-industry partnership demonstrates CBCT with low radiation dose, sub-mm spatial resolution, and soft-tissue visibility potentially approaching that of diagnostic CT. Integration of the 3D imaging system with real-time tracking, deformable registration, endoscopic video, and 3D visualization offers a promising addition to the surgical arsenal in interventions ranging from head-and-neck/skull base surgery to spine, orthopaedic, thoracic, and abdominal surgeries. Cadaver studies show the potential for significant boosts in surgical

  20. Cone-beam CT with a flat-panel detector: From image science to image-guided surgery

    Energy Technology Data Exchange (ETDEWEB)

    Siewerdsen, Jeffrey H., E-mail: jeff.siewerdsen@jhu.edu [Department of Biomedical Engineering, Johns Hopkins University, Traylor Building, Room 718, 720 Rutland Avenue, Baltimore, MD 21205 (United States)

    2011-08-21

    The development of large-area flat-panel X-ray detectors (FPDs) has spurred investigation in a spectrum of advanced medical imaging applications, including tomosynthesis and cone-beam CT (CBCT). Recent research has extended image quality metrics and theoretical models to such applications, providing a quantitative foundation for the assessment of imaging performance as well as a general framework for the design, optimization, and translation of such technologies to new applications. For example, cascaded systems models of the Fourier domain metrics, such as noise-equivalent quanta (NEQ), have been extended to these modalities to describe the propagation of signal and noise through the image acquisition and reconstruction chain and to quantify the factors that govern spatial resolution, image noise, and detectability. Moreover, such models have demonstrated basic agreement with human observer performance for a broad range of imaging conditions and imaging tasks. These developments in image science have formed a foundation for the knowledgeable development and translation of CBCT to new applications in image-guided interventions-for example, CBCT implemented on a mobile surgical C-arm for intraoperative 3D imaging. The ability to acquire high-quality 3D images on demand during surgical intervention overcomes conventional limitations of surgical guidance in the context of preoperative images alone. A prototype mobile C-arm developed in academic-industry partnership demonstrates CBCT with low radiation dose, sub-mm spatial resolution, and soft-tissue visibility potentially approaching that of diagnostic CT. Integration of the 3D imaging system with real-time tracking, deformable registration, endoscopic video, and 3D visualization offers a promising addition to the surgical arsenal in interventions ranging from head-and-neck/skull base surgery to spine, orthopaedic, thoracic, and abdominal surgeries. Cadaver studies show the potential for significant boosts in surgical

  1. Terminal illness and access to Phase 1 experimental agents, surgeries and devices: reviewing the ethical arguments.

    Science.gov (United States)

    Schüklenk, Udo; Lowry, Christopher

    2009-01-01

    The advent of AIDS brought about a group of patients unwilling to accept crucial aspects of the methodological standards for clinical research investigating Phase 1 drugs, surgeries or devices. Their arguments against placebo controls in trials, which depended--at the time--on the terminal status of patient volunteers led to a renewed discussion of the ethics of denying patients with catastrophic illnesses access to last-chance experimental drugs, surgeries or devices. Existing ethics and health policy literature on the topic of access to experimental drugs. The positions of those arguing for or against free access to experimental drugs for terminally ill patients are irreconcilable. At stake are questions about the kinds of personal sacrifices society can reasonably expect patients in clinical trials to make to ensure statistically predictive results. These would benefit by necessity a much larger number of current and future patients--the conflict is about individual versus public interests. It is also about the question of whether or not the state can legitimately prevent patients with terminal illnesses from unfettered access to experimental drugs, surgeries or devices in order to motivate them to participate in clinical trials. We review the ethical arguments for and against the provision of access to Phase 1 agents for terminally ill patients. Finding a compromise between providing free or no access to Phase 1 drugs for terminally ill patients. We ought to investigate means to increase access to experimental drugs for terminally ill patients without sacrificing necessary clinical trials' sounds scientific methods.

  2. 75 FR 36102 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-06-24

    ... will discuss, make recommendations, and vote on premarket approval application for MelaFind, sponsored by MELA Sciences, Inc. MelaFind is a non-invasive computer vision system intended to assist in the... characteristics of melanoma, before a final decision to biopsy has been rendered. MelaFind acquires and displays...

  3. [Impact of an automated dispensing system for medical devices in cardiac surgery department].

    Science.gov (United States)

    Clou, E; Dompnier, M; Kably, B; Leplay, C; Poupon, E; Archer, V; Paul, M

    2018-01-01

    To secure medical devices' management, the implementation of automated dispensing system in surgical service has been realized. The objective of this study was to evaluate security, organizational and economic impact of installing automated dispensing system for medical devices (ASDM). The implementation took place in a cardiac surgery department. Security impact was assessed by comparing traceability rate of implantable medical devices one year before and one year after installation. Questionnaire on nurses' perception and satisfaction completed this survey. Resupplying costs, stocks' evolution and investments for the implementation of ASDM were the subject of cost-benefit study. After one year, traceability rate is excellent (100%). Nursing staffs were satisfied with 87.5% by this new system. The introduction of ASDM allowed a qualitative and quantitative decrease in stocks, with a reduction of 30% for purchased medical devices and 15% for implantable medical devices in deposit-consignment. Cost-benefit analysis shows a rapid return on investment. Real stock decrease (purchased medical devices) is equivalent to 46.6% of investment. Implementation of ASDM allows to secure storage and dispensing of medical devices. This system has also an important economic impact and appreciated by users. Copyright © 2017 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  4. NPC Based Design Optimization for a Net Zero Office Building in Hot Climates with PV Panels as Shading Device

    Directory of Open Access Journals (Sweden)

    Muhammad Zubair

    2018-05-01

    Full Text Available Hot areas of the world receive a high amount of solar radiation. As a result, buildings in those areas consume more energy to maintain a comfortable climate for their inhabitants. In an effort to design net-zero energy building in hot climates, PV possesses the unique advantage of generating electrical energy while protecting the building from solar irradiance. In this work, to form a net-zero energy building (NZEB, renewable resources such as solar and wind available onsite for an existing building have been analyzed in a hot climate location. PV and wind turbines in various configurations are studied to form a NZEB, where PV-only systems offer better performance than Hybrid PV Wind systems, based on net present cost (NPC. The self-shading losses in PV placed on rooftop areas are analyzed by placing parallel arrays of PV modules at various distances in between them. The effect on building cooling load by rooftop PV panels as shading devices is investigated. Furthermore, self-shading losses of PV are compared by the savings in cooling loads using PV as shading. In the case study, 12.3% saving in the cooling load of the building is observed when the building rooftop is completed shaded by PV panels; annual cooling load decreased from 3.417 GWh to 2.996 GWh, while only 1.04% shaded losses are observed for fully shaded (FS buildings compared to those with no shading (NS, as PV generation decreases from 594.39 kWh/m2 to 588.21 kWh/m2. The net present cost of the project has been decreased from US$4.77 million to US$4.41 million by simply covering the rooftop completely with PV panels, for a net-zero energy building.

  5. Impact of Tricuspid Valve Surgery at the Time of Left Ventricular Assist Device Insertion on Postoperative Outcomes

    OpenAIRE

    Dunlay, Shannon M.; Deo, Salil V.; Park, Soon J.

    2015-01-01

    Tricuspid regurgitation (TR) is common in patients with heart failure undergoing left ventricular assist device (LVAD) implantation. Whether the TR should be surgically managed at the time of LVAD surgery is controversial.

  6. Investigational Clinical Trial of a Prototype Optoelectronic Computer-Aided Navigation Device for Dental Implant Surgery.

    Science.gov (United States)

    Jokstad, Asbjørn; Winnett, Brenton; Fava, Joseph; Powell, David; Somogyi-Ganss, Eszter

    New digital technologies enable real-time computer-aided (CA) three-dimensional (3D) guidance during dental implant surgery. The aim of this investigational clinical trial was to demonstrate the safety and effectiveness of a prototype optoelectronic CA-navigation device in comparison with the conventional approach for planning and effecting dental implant surgery. Study participants with up to four missing teeth were recruited from the pool of patients referred to the University of Toronto Graduate Prosthodontics clinic. The first 10 participants were allocated to either a conventional or a prototype device study arm in a randomized trial. The next 10 participants received implants using the prototype device. All study participants were restored with fixed dental prostheses after 3 (mandible) or 6 (maxilla) months healing, and monitored over 12 months. The primary outcome was the incidence of any surgical, biologic, or prosthetic adverse events or device-related complications. Secondary outcomes were the incidence of positioning of implants not considered suitable for straightforward prosthetic restoration (yes/no); the perception of the ease of use of the prototype device by the two oral surgeons, recorded by use of a Likert-type questionnaire; and the clinical performance of the implant and superstructure after 1 year in function. Positioning of the implants was appraised on periapical radiographs and clinical photographs by four independent blinded examiners. Peri-implant bone loss was measured on periapical radiographs by a blinded examiner. No adverse events occurred related to placing any implants. Four device-related complications led to a switch from using the prototype device to the conventional method. All implants placed by use of the prototype device were in a position considered suitable for straightforward prosthetic restoration (n = 21). The qualitative evaluation by the surgeons was generally positive, although ergonomic challenges were identified

  7. RETRACTED: Six different hemofiltration devices for blood conservation in cardiac surgery.

    Science.gov (United States)

    Boldt, J; Zickmann, B; Fedderson, B; Herold, C; Dapper, F; Hempelmann, G

    1991-05-01

    Hemofiltration devices and the Cell Saver are the most often used techniques to reduce homologous blood requirements in cardiac surgery. In a controlled, randomized study, 105 patients underwent elective aortocoronary bypass grafting. Six different hemofilters (HF-80, HFT 14, CPB 7000, Cobe 1200, UF-205, BC-140) were tested and compared with the Cell Saver (Cell Saver 4) for blood concentration during and after cardiopulmonary bypass. Efficacy, practicality, and laboratory indices including coagulation variables were documented through the morning of the first postoperative day. The HF-80 and UF-205 were the most effective devices for blood concentration. At the end of the operation, the number of platelets was least reduced in these two groups (HF-80, -7%; UF-205, -6%). Moreover, both devices had a significantly higher filtration rate than the other hemofilters. Use of the Cell Saver resulted in the lowest values in coagulation variables (AT-III, fibrinogen, number of platelets) and the most pronounced deterioration in protein homeostasis (colloid osmotic pressure, albumin). In this group, the AT-III concentration was reduced until the morning of the first postoperative day. No negative effects were seen in regard to hemofiltration (free hemoglobin and polymorphonuclear elastase; the Cell Saver group had similar values for these variables). We conclude that blood salvage with hemofiltration devices is superior to that with the Cell Saver. There were, however, significant differences among the hemofilters. The HF-80 and UF-205 were the most effective devices in this study.

  8. Clinical Evaluation of Measuring the ACT during Elective Cardiac Surgery with Two Different Devices.

    Science.gov (United States)

    Falter, Florian; Razzaq, Nabeel; John, Martin; Fassl, Jens; Maurer, Markus; Ewing, Sean; Hofmeyr, Ross

    2018-03-01

    Unfractionated heparin is the mainstay of anticoagulation during cardiac surgery on cardiopulmonary bypass (CPB) due to its low cost, quick onset, and ease of reversal. Since over 30 years, the activated clotting time (ACT) has been used to assess the level of heparin activity both before and after CPB. We compared two different methods of measuring the ACT: i-STAT, which uses amperometric detection of thrombin cleavage, and Hemochron Jr, which is based on detecting viscoelastic changes in blood. We included 402 patients from three institutions (Papworth Hospital, Cambridge, UK; Groote Schuur, Cape Town, South Africa; University Hospital Basel, Basel, Switzerland) undergoing elective cardiac surgery on CPB in our study. We analyzed duplicate samples on both devices at all standard measuring points during the procedure. The correlation coefficient between two Hemochron and two i-STAT devices was .9165 and .9857, respectively. The within-subject coefficient of variation (WSCV) ranged from 8.2 to 13.6% for the Hemochron and from 4.1 to 9.1% for the i-STAT. We found that the number of occasions where one of the duplicate readings was >1,000 seconds while the other was below or close to the clinically significant threshold of 400 seconds were higher for the Hemochron. We found the i-STAT to systematically return higher measurements. We conclude that the i-STAT provides a more reliable test for heparin activity and assesses safe anticoagulation during cardiac surgery on pump. The fact the that the i-STAT reads higher than the Hemochron leads to the recommendation to validate the methods against each other before changing devices.

  9. Microvascular anastomosis using the vascular closure device in free flap reconstructive surgery: A 13-year experience.

    Science.gov (United States)

    Reddy, Chaitan; Pennington, David; Stern, Harvey

    2012-02-01

    The achievement of patency of the microvascular anastomosis in free flap surgery is dependent on a number of factors, central to which is atraumatic handling of the vessel lumen, and intimal apposition. Initial laboratory studies demonstrating the superiority of the non-penetrating vascular closure staple (VCS - Anastoclip ®) were followed by our report in 1999 on a series of free flaps. There is still a paucity of data in the literature on the use of non-penetrating devices for microvascular anastomosis, and our review gives evidence to support the routine use of the VCS in microsurgical free flap surgery. We now report on its successful use over a thirteen year period in 819 free flap reconstructions. Our data indicates the VCS device to be as effective as sutured anastomoses in free tissue transfer surgery. There is also statistically significant data (Barnard's Exact Test) to demonstrate a higher vascular patency rate of the VCS device over sutured anastomoses when sub group analysis is performed. 'Take-back' revision rates were lower amongst flaps that employed VCS use. For arterial anastomoses, this equated to 3/654(0.05%) vs 4/170(2.4%) with hand-sewn anastomoses (p = 0.02). Similarly, for venous anastomoses the 'take-back' revision rate was 7/661(1.1%) vs 8/165(4.8%) with hand-sewn anastomoses (p = 0.003). Furthermore, the major advantage of the VCS is reduction in anastomosis time, from approximately 25 min per anastomosis for sutures to between five and 10 min for staples. Copyright © 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. [Incidence of urinary tract infections after cardiac surgery: comparative study accordind to catheterization device].

    Science.gov (United States)

    Hidalgo Fabrellas, I; Rebollo Pavón, M; Planas Canals, M; Barbero Cabezas, M

    2015-01-01

    Urinary tract infections (UTI) associated with urethral catheterization are the second cause of nosocomial infections in Intensive care units. We confirm a UTI when we get a result of 100,000 CFU/ml with at least one microorganism in a urine culture. Compare and determine the incidence of UTI in cardiac surgery postpoperative patients according to the catheterization device. A prospective, randomized analytical observational study of patients in the immediate cardiac surgery postoperative period. One group was probed with catheter Foley and one was inserted the catheter BIPFoley-Bactiguard® (CBF). The CBF is coated with noble metals (silver, gold and palladium) and biocompatible antimicrobial properties, covering the entire surface of the device and prevents the formation of biofilm, microbial adherence and colonization. 116 cases, 59.5% (69 cases) were negative for UTI and 40.5% (47 cases) were positive. Out of the positive UTI results, 25% were carriers of catheter Foley and 15.5% of CBF. Most common etiologic microorganisms: Escherichia coli 29.8% Klebsiella pneumonia 29.8%, Klebsiella oxytoca 9%. With the data we have observed that patients catheterized BIPfoley-Bactiguard® are infected to a lesser extent than Foley carriers. Copyright © 2013 Elsevier España, S.L.U. y SEEIUC. All rights reserved.

  11. Heterologous, Fresh, Human Donor Sclera as Patch Graft Material in Glaucoma Drainage Device Surgery.

    Science.gov (United States)

    Tsoukanas, Dimitrios; Xanthopoulou, Paraskevi; Charonis, Alexandros C; Theodossiadis, Panagiotis; Kopsinis, Gerasimos; Filippopoulos, Theodoros

    2016-07-01

    To determine the safety and efficacy of fresh, human sclera allografts as a patch graft material in glaucoma drainage device (GDD) surgery. Retrospective, noncomparative, interventional, consecutive case series. All GDD cases operated between 2008 and 2013 in which fresh human corneoscleral rims were used immediately after the central corneal button was used for penetrating or endothelial keratoplasty. Surgery was performed by 2 surgeons at 2 facilities. The Ahmed Glaucoma Valve (FP-7) was used exclusively in this cohort. Sixty-four eyes of 60 patients were identified; demographic data were recorded along with intraocular pressure (IOP), medication requirements, visual acuity, complications, and subsequent interventions. Incidence of complications. IOP and medication requirements at the last follow-up. Quilified success utilizing Tube Versus Trabeculectomy study criteria. The mean age of the cohort was 66.2±19.1 years; the average preoperative IOP was 33.2±11.1 mm Hg on 4.2±1.3 IOP-lowering agents before GDD surgery. IOP decreased significantly to 14.1±4.7 mm Hg (Pendophthalmitis, and there was 1 case of conjunctival erosion and tube/plate exposure (1.6%) occurring 30 days after surgery. Qualified success was estimated as 90.5% and 81% at 1 and 2 years, respectively, using Tube Versus Trabeculectomy study criteria. Heterologous, fresh, human donor sclera appears to be a safe material for GDD tube coverage. It provides a cost-efficient alternative compared with traditional patch graft materials associated with a low risk of pathogen transmission.

  12. Effects of Lumbar Fusion Surgery with ISOBAR Devices Versus Posterior Lumbar Interbody Fusion Surgery on Pain and Disability in Patients with Lumbar Degenerative Diseases: A Meta-Analysis.

    Science.gov (United States)

    Su, Shu-Fen; Wu, Meng-Shan; Yeh, Wen-Ting; Liao, Ying-Chin

    2018-06-01

    Purpose/Aim: Lumbar degenerative diseases (LDDs) cause pain and disability and are treated with lumbar fusion surgery. The aim of this study was to evaluate the efficacy of lumbar fusion surgery with ISOBAR devices versus posterior lumbar interbody fusion (PLIF) surgery for alleviating LDD-associated pain and disability. We performed a literature review and meta-analysis conducted in accordance with Cochrane methodology. The analysis included Group Reading Assessment and Diagnostic Evaluation assessments, Jadad Quality Score evaluations, and Risk of Bias in Non-randomized Studies of Interventions assessments. We searched PubMed, MEDLINE, the Cumulative Index to Nursing and Allied Health Literature, the Cochrane Library, ProQuest, the Airiti Library, and the China Academic Journals Full-text Database for relevant randomized controlled trials and cohort studies published in English or Chinese between 1997 and 2017. Outcome measures of interest included general pain, lower back pain, and disability. Of the 18 studies that met the inclusion criteria, 16 examined general pain (802 patients), 5 examined lower back pain (274 patients), and 15 examined disability (734 patients). General pain, lower back pain, and disability scores were significantly lower after lumbar fusion surgery with ISOBAR devices compared to presurgery. Moreover, lumbar fusion surgery with ISOBAR devices was more effective than PLIF for decreasing postoperative disability, although it did not provide any benefit in terms of general pain or lower back pain. Lumbar fusion surgery with ISOBAR devices alleviates general pain, lower back pain, and disability in LDD patients and is superior to PLIF for reducing postoperative disability. Given possible publication bias, we recommend further large-scale studies.

  13. Corneal decompensation following filtering surgery with the Ex-PRESS® mini glaucoma shunt device

    Directory of Open Access Journals (Sweden)

    Tojo N

    2015-03-01

    Full Text Available Naoki Tojo, Atsushi Hayashi, Akio Miyakoshi Department of Ophthalmology, Graduate School of Medicine and Pharmaceutical Sciences, University of Toyama, Toyama, Japan Purpose: To report a case of corneal decompensation due to the Ex-PRESS® mini glaucoma shunt device (Ex-PRESS.Patient and methods: A 75-year-old man had pseudoexfoliation glaucoma in his right eye. He underwent filtration surgery with Ex-PRESS. His intraocular pressure was 7 mmHg after 9 months.Results: We observed partial decompensation of the corneal endothelium adjacent to the filtering bleb. Specular microscopy revealed a marked decrease in the endothelial cell density at the center of the cornea.Conclusion: Anterior segment optical coherence tomography is very useful for evaluating corneal edema and the position of Ex-PRESS. It is important to follow up with an examination of the corneal endothelial cells. Keywords: Ex-PRESS, bullous keratopathy, trabeculectomy, complication, cornea 

  14. A new mild hyperthermia device to treat vascular involvement in cancer surgery.

    Science.gov (United States)

    Ware, Matthew J; Nguyen, Lam P; Law, Justin J; Krzykawska-Serda, Martyna; Taylor, Kimberly M; Cao, Hop S Tran; Anderson, Andrew O; Pulikkathara, Merlyn; Newton, Jared M; Ho, Jason C; Hwang, Rosa; Rajapakshe, Kimal; Coarfa, Cristian; Huang, Shixia; Edwards, Dean; Curley, Steven A; Corr, Stuart J

    2017-09-12

    Surgical margin status in cancer surgery represents an important oncologic parameter affecting overall prognosis. The risk of disease recurrence is minimized and survival often prolonged if margin-negative resection can be accomplished during cancer surgery. Unfortunately, negative margins are not always surgically achievable due to tumor invasion into adjacent tissues or involvement of critical vasculature. Herein, we present a novel intra-operative device created to facilitate a uniform and mild heating profile to cause hyperthermic destruction of vessel-encasing tumors while safeguarding the encased vessel. We use pancreatic ductal adenocarcinoma as an in vitro and an in vivo cancer model for these studies as it is a representative model of a tumor that commonly involves major mesenteric vessels. In vitro data suggests that mild hyperthermia (41-46 °C for ten minutes) is an optimal thermal dose to induce high levels of cancer cell death, alter cancer cell's proteomic profiles and eliminate cancer stem cells while preserving non-malignant cells. In vivo and in silico data supports the well-known phenomena of a vascular heat sink effect that causes high temperature differentials through tissues undergoing hyperthermia, however temperatures can be predicted and used as a tool for the surgeon to adjust thermal doses delivered for various tumor margins.

  15. Which hemostatic device in thyroid surgery? A network meta-analysis of surgical technologies.

    Science.gov (United States)

    Garas, George; Okabayashi, Koji; Ashrafian, Hutan; Shetty, Kunal; Palazzo, Fausto; Tolley, Neil; Darzi, Ara; Athanasiou, Thanos; Zacharakis, Emmanouil

    2013-09-01

    Energy-based hemostatic devices are increasingly being used in thyroid surgery. However, there are several limitations with regard to the existing evidence and a paucity of guidelines on the subject. The goal of this review is to employ the novel evidence synthesis technique of a network meta-analysis to assess the comparative effectiveness of surgical technologies in thyroid surgery and contribute to enhanced governance in the field of thyroid surgery. Articles published between January 2000 and June 2012 were identified from Embase, Medline, Cochrane Library, and PubMed databases. Randomized controlled trials of any size comparing the use of ultrasonic coagulation (harmonic scalpel) or Ligasure either head-to-head or against the "clamp-and-tie" technique were included. Two reviewers independently critically appraised and extracted the data from each study. The number of patients who experienced postoperative events was extracted in dichotomous format or continuous outcomes. Odds ratios were calculated by a Bayesian network meta-analysis, and metaregression was used for pair-wise comparisons. Indirect and direct comparisons were performed and inconsistency was assessed. Thirty-five randomized controlled trials with 2856 patients were included. Ultrasonic coagulation ranked first (followed by Ligasure and then clamp-and-tie) with the lowest risk of postoperative hypoparathyroidism (odds ratio 1.43 [95% confidence interval (CI) 0.77-2.67] and 0.70 [CI 0.43-1.13], ultrasonic coagulation vs. Ligasure and ultrasonic coagulation vs. clamp-and-tie, respectively), least blood loss (-0.25 [CI -0.84 to -0.35] and -1.22 [CI -1.85 to -0.59]), and drain output (0.28 [CI -0.35 to -0.91] and -0.36 [CI -0.70 to -0.03]). From a health technology viewpoint, ultrasonic coagulation was associated with the shortest operative time (-0.66 [CI -1.17 to -0.14] and -1.29 [CI -1.59 to -1.00]) and hospital stay (-0.28 [CI -0.78 to 0.22] and -0.56 [CI -1.28 to 0.15]). The only exception

  16. Extending the reach of stapled anastomosis with a prepared OrVil™ device in laparoscopic oesophageal and gastric cancer surgery.

    LENUS (Irish Health Repository)

    Salih, Abdelmonim E A

    2014-08-27

    The introduction of minimally invasive surgery and the use of laparoscopic techniques have significantly improved patient outcomes and have offered a new range of options for the restoration of intestinal continuity. Various reconstruction techniques have been described and various devices employed but none has been established as superior. This study evaluates our experience with, and modifications of, the orally inserted anvil (OrVil™).

  17. Manual accuracy in comparison with a miniature master slave device--preclinical evaluation for ear surgery.

    Science.gov (United States)

    Runge, A; Hofer, M; Dittrich, E; Neumuth, T; Haase, R; Strauss, M; Dietz, A; Lüth, T; Strauss, G

    2011-01-01

    Manual accuracy in microsurgery is reduced by tremor and limited access. A surgical approach through the middle ear also puts delicate structures at risk, while the surgeon is often working at an unergonomic position. At this point a micromanipulator could have a positive influence. A system was developed to measure "working accuracy", time and precision during manipulation in the middle ear. 10 ENT-surgeons simulated a perforation of the stapedial footplate on a modified 3D print of a human skull in a mock OR. Each trial was repeated more than 200 times aiming manually and using a micro-manipulator. Data of over 4000 measurements was tested and graphically processed. Work strain was evaluated with a questionnaire. Accuracy for manual and micromanipulator perforation revealed a small difference. Learning curves showed a stronger decrease both in deviation and time when the micromanipulator was used. Also a lower work strain was apparent. The micromanipulator has the potential as an aiding device in ear surgery.

  18. Non-infected penile prosthesis cultures during revision surgery; comparison between antibiotic coated and non - coated devices

    Directory of Open Access Journals (Sweden)

    Seyfettin Ciftci

    Full Text Available ABSTRACT Introduction: Aim of this study is to investigate bacterial growth on non-infected devices and compare antibiotic-coated and non-coated implants. Materials and methods: The charts of 71 patients who underwent revision surgeries for penile prosthesis between 1995 and 2013 were reviewed. Of those, 31 devices were antibiotic-coated prostheses, while 40 of the implants were non-coated. Swab cultures were routinely obtained from corporal, pump or reservoir site during the operation. If a bacterial biofilm was determined on the prosthesis, it was also cultured. Results: A total of 5 different organisms were cultured from 18 patients. Of them, 4 devices were antibiotic-coated and the other 14 were non-coated devices. Staphylococcus epidermidis was the most common organism, while Staphylococcus hominis, beta hemolitic streptococcus, Escherichia coli and Proteus mirabilis were also cultured. All patients who had positive cultures were treated with appropriate antibiotics for four weeks postoperatively. Median follow-up time was 41 months, ranging between 8 and 82 months. One prosthesis (non-coated became clinically infected in the follow-up period with a totally different organism. Culture positivity rates of antibiotic-coated and non-coated devices were 13% and 35% respectively and the result was significant (p=0.00254. Conclusions: Positive bacterial cultures are present on non-infected penile prostheses at revision surgeries in some of the patients. Antibiotic coated prostheses have much less positive cultures than non-coated devices.

  19. Comparison of corneal power obtained from VERION image-guided surgery system and four other devices

    Directory of Open Access Journals (Sweden)

    Lin HY

    2017-07-01

    Full Text Available Hung-Yuan Lin,1,* Hsin-Yang Chen,1,2,* Han Bor Fam,3 Ya-Jung Chuang,1 Ronald Yeoh,4 Pi-Jung Lin5 1Universal Eye Center, Zhongli Branch, Zhongli County, TaoYuan City, Taiwan, Republic of China; 2Ophthalmology Department, Ningbo First Hospital, Ningbo, Zhejiang Province, People’s Republic of China; 3Ophthalmology Department, Tan Tock Seng Hospital, Jalan Tan Tock Seng, 4Ophthalmology Department, Eye and Retina Surgeons, Camden Medical Centre, Singapore; 5Universal Eye Center, Xinnan Branch, Taipei City, Taiwan, Republic of China *These authors contributed equally to this work Purpose: To assess the corneal keratometric values obtained using the VERION image-guided surgery system and other devices.Methods: This study evaluated the right eyes of 115 cataract patients before intraocular lens (IOL implantation through consecutive tests using 5 devices: VERION Reference Unit , Placido-based corneal topography (OPD-Scan III, monochromatic light-emitting diodes (LenStar LS900 and AL-Scan, and rotary prism technology (auto kerato-refractometer KR-8800. Analyzed parameters were corneal steep and flat keratometric values (Ks and Kf and corneal astigmatism and axis. These parameters were evaluated using the one-sample two-tailed t-test and the 95% limits of agreement (95% LOAs between the devices.Results: The mean corneal cylinder value measurements were -0.97±0.63 D, -0.88± 0.60 D, -0.90±0.69 D, -0.90±0.67 D, and -0.83±0.60 D with VERION, LenStar, AL-Scan (2.4 mm, OPD III, and KR-8800, respectively. Only KR-8800 showed a significant difference from VERION in the corneal cylinder value (P<0.05. The mean differences in the Kf and Ks of VERION compared to those of OPD III were 0.18±0.45 D and 0.17±0.38 D (P<0.05, respectively. The 95% LOAs of Bland–Altman analysis for the corneal astigmatism axis of the VERION with LenStar, AL-Scan (2.4 mm, OPD III, and KR-8800 were -26.25° to 58.71°, -20.61° to 47.44°, -25.03° to 58.98°, and -27.85

  20. Ethics, economics and the regulation and adoption of new medical devices: case studies in pelvic floor surgery

    Directory of Open Access Journals (Sweden)

    Ross Sue

    2010-08-01

    Full Text Available Abstract Background Concern has been growing in the academic literature and popular media about the licensing, introduction and adoption of surgical devices before full effectiveness and safety evidence is available to inform clinical practice. Our research will seek empirical survey evidence about the roles, responsibilities, and information and policy needs of the key stakeholders in the introduction into clinical practice of new surgical devices for pelvic floor surgery, in terms of the underlying ethical principals involved in the economic decision-making process, using the example of pelvic floor procedures. Methods/Design Our study involves three linked case studies using, as examples, selected pelvic floor surgery devices representing Health Canada device safety risk classes: low, medium and high risk. Data collection will focus on stakeholder roles and responsibilities, information and policy needs, and perceptions of those of other key stakeholders, in seeking and using evidence about new surgical devices when licensing and adopting them into practice. For each class of device, interviews will be used to seek the opinions of stakeholders. The following stakeholders and ethical and economic principles provide the theoretical framework for the study: Stakeholders - federal regulatory body, device manufacturers, clinicians, patients, health care institutions, provincial health departments, and professional societies. Clinical settings in two centres (in different provinces will be included. Ethics - beneficence, non-maleficence, autonomy, justice. Economics - scarcity of resources, choices, opportunity costs. For each class of device, responses will be analysed to compare and contrast between stakeholders. Applied ethics and economic theory, analysis and critical interpretation will be used to further illuminate the case study material. Discussion The significance of our research in this new area of ethics will lie in providing

  1. Ethics, economics and the regulation and adoption of new medical devices: case studies in pelvic floor surgery

    Science.gov (United States)

    2010-01-01

    Background Concern has been growing in the academic literature and popular media about the licensing, introduction and adoption of surgical devices before full effectiveness and safety evidence is available to inform clinical practice. Our research will seek empirical survey evidence about the roles, responsibilities, and information and policy needs of the key stakeholders in the introduction into clinical practice of new surgical devices for pelvic floor surgery, in terms of the underlying ethical principals involved in the economic decision-making process, using the example of pelvic floor procedures. Methods/Design Our study involves three linked case studies using, as examples, selected pelvic floor surgery devices representing Health Canada device safety risk classes: low, medium and high risk. Data collection will focus on stakeholder roles and responsibilities, information and policy needs, and perceptions of those of other key stakeholders, in seeking and using evidence about new surgical devices when licensing and adopting them into practice. For each class of device, interviews will be used to seek the opinions of stakeholders. The following stakeholders and ethical and economic principles provide the theoretical framework for the study: Stakeholders - federal regulatory body, device manufacturers, clinicians, patients, health care institutions, provincial health departments, and professional societies. Clinical settings in two centres (in different provinces) will be included. Ethics - beneficence, non-maleficence, autonomy, justice. Economics - scarcity of resources, choices, opportunity costs. For each class of device, responses will be analysed to compare and contrast between stakeholders. Applied ethics and economic theory, analysis and critical interpretation will be used to further illuminate the case study material. Discussion The significance of our research in this new area of ethics will lie in providing recommendations for regulatory bodies

  2. Clinical protocol levels are required in laboratory animal surgery when using medical devices: experiences with ureteral replacement surgery in goats

    NARCIS (Netherlands)

    Jonge, P.K.J.D. de; Sloff, M.; Janke, H.P.; Kortmann, B.B.M.; Gier, R.P.E. de; Geutjes, P.J.; Oosterwijk, E.; Feitz, W.F.J.

    2017-01-01

    It is common to test medical devices in large animal studies that are or could also be used in humans. In this short report we describe the use of a ureteral J-stent for the evaluation of biodegradable tubular constructs for tissue reconstruction, and the regeneration of ureters in Saanen goats.

  3. Development of Transvaginal Uterus Amputation Device for Laparoscopic Hysterectomies in Gynecologic Surgeries

    Directory of Open Access Journals (Sweden)

    Serkan DİKİCİ

    2015-01-01

    Full Text Available Hysterectomy, that is removal of uterus, is one of the most common major operations in gynecologic surgeries. Laparoscopy technique is preferred in hysterectomy because of its advantages such as lower intra-operative blood loss, decreased surrounding tissue/organ damage, less operating time, lower postoperative infection and frequency of fever, shorter duration of hospitalization and post-operative returning time to normal activity. During total laparoscopic hysterectomy, first uterine vessels and ligaments are cauterized respectively, and then cervicovaginal connections are cauterized and coagulated to remove uterus completely. Uterine manipulators are used during laparoscopy to maximize the endoscopic vision of surgeons by moving related organs. However, conventional uterine manipulators have important drawbacks particularly to move uterus in three dimensions and to show cervicovaginal landmark during laparoscopic circular cauterization and amputation of the uterine cervix. A new transvaginal uterine manipulator may overcome these two important drawbacks of these currently available devices. For this reason, a3D scanned technique was used to get uterus sizes and computer aided design software is used in designing of the new manipulator and then 3D printer was used in prototyping. Special light emitting diodes (LEDs were mounted on the cervical cap of the manipulator to guide light beams from inside of cervicovaginal tissue to abdominal cavity to facilitate the visualization of tissue landmarks. Moreover, performances of different caps and LED systems will be evaluated. Furthermore, after integration of self-cutting and self-suturing mechanisms into our system, final prototype will be produced by using titanium which is biologically and mechanically appropriate. Therefore, aim of this study was to design and produce a new uterine manipulator with three dimensional movements, LED illumination, self-cutting and self-suturing systems to facilitate

  4. An Intestinal Occlusion Device for Prevention of Small Bowel Distention During Transgastric Natural Orifice Transluminal Endoscopic Surgery

    OpenAIRE

    Tomasko, Jonathan M.; Mathew, Abraham; Moyer, Matthew T.; Haluck, Randy S.; Pauli, Eric M.

    2013-01-01

    Background and Objectives: Bowel distention from luminal gas insufflation reduces the peritoneal operative domain during natural orifice transluminal endoscopic surgery (NOTES) procedures, increases the risk for iatrogenic injury, and leads to postoperative patient discomfort. Methods: A prototype duodenal occlusion device was placed in the duodenum before NOTES in 28 female pigs. The occlusion balloon was inflated and left in place during the procedure, and small bowel distension was subject...

  5. Drug, devices, technologies, and techniques for blood management in minimally invasive and conventional cardiothoracic surgery: a consensus statement from the International Society for Minimally Invasive Cardiothoracic Surgery (ISMICS) 2011.

    Science.gov (United States)

    Menkis, Alan H; Martin, Janet; Cheng, Davy C H; Fitzgerald, David C; Freedman, John J; Gao, Changqing; Koster, Andreas; Mackenzie, G Scott; Murphy, Gavin J; Spiess, Bruce; Ad, Niv

    2012-01-01

    The objectives of this consensus conference were to evaluate the evidence for the efficacy and safety of perioperative drugs, technologies, and techniques in reducing allogeneic blood transfusion for adults undergoing cardiac surgery and to develop evidence-based recommendations for comprehensive perioperative blood management in cardiac surgery, with emphasis on minimally invasive cardiac surgery. The consensus panel short-listed the potential topics for review from a comprehensive list of potential drugs, devices, technologies, and techniques. The process of short-listing was based on the need to prioritize and focus on the areas of highest importance to surgeons, anesthesiologists, perfusionists, hematologists, and allied health care involved in the management of patients who undergo cardiac surgery whether through the conventional or minimally invasive approach. MEDLINE, Cochrane Library, and Embase databases were searched from their date of inception to May 2011, and supplemental hand searches were also performed. Detailed methodology and search strategies are outlined in each of the subsequently published systematic reviews. In general, all relevant synonyms for drugs (antifibrinolytic, aprotinin, [Latin Small Letter Open E]-aminocaproic acid, tranexamic acid [TA], desmopressin, anticoagulants, heparin, antiplatelets, anti-Xa agents, adenosine diphosphate inhibitors, acetylsalicylic acid [ASA], factor VIIa [FVIIa]), technologies (cell salvage, miniaturized cardiopulmonary bypass (CPB) circuits, biocompatible circuits, ultrafiltration), and techniques (transfusion thresholds, minimally invasive cardiac or aortic surgery) were searched and combined with terms for blood, red blood cells, fresh-frozen plasma, platelets, transfusion, and allogeneic exposure. The American Heart Association/American College of Cardiology system was used to label the level of evidence and class of each recommendation. Database search identified more than 6900 articles, with 4423 full

  6. Clinical protocol levels are required in laboratory animal surgery when using medical devices: experiences with ureteral replacement surgery in goats

    OpenAIRE

    de Jonge, Paul K. J. D.; Sloff, Marije; Janke, Heinz P.; Kortmann, Barbara B. M.; de Gier, Robert P. E.; Geutjes, Paul J.; Oosterwijk, Egbert; Feitz, Wout F. J.

    2017-01-01

    It is common to test medical devices in large animal studies that are or could also be used in humans. In this short report we describe the use of a ureteral J-stent for the evaluation of biodegradable tubular constructs for tissue reconstruction, and the regeneration of ureters in Saanen goats. Similarly to a previous study in pigs, the ureteral J-stent was blindly inserted until some resistance was met. During evaluation of the goats after three months, perforation of the renal cortex by th...

  7. Reflecting variable opening insulating panel

    International Nuclear Information System (INIS)

    Nungesser, W.T.

    1976-01-01

    A description is given of a reflecting variable opening insulating panel assembly, comprising a static panel assembly of reflecting insulation sheets forming a cavity along one side of the panel and a movable panel opening out by sliding from the cavity of the static panel, and a locking device for holding the movable panel in a position extending from the cavity of the static panel. This can apply to a nuclear reactor of which the base might require maintenance and periodical checking and for which it is desirable to have available certain processes for the partial dismantling of the insulation [fr

  8. Clinical protocol levels are required in laboratory animal surgery when using medical devices: experiences with ureteral replacement surgery in goats.

    Science.gov (United States)

    de Jonge, Paul K J D; Sloff, Marije; Janke, Heinz P; Kortmann, Barbara B M; de Gier, Robert P E; Geutjes, Paul J; Oosterwijk, Egbert; Feitz, Wout F J

    2017-10-01

    It is common to test medical devices in large animal studies that are or could also be used in humans. In this short report we describe the use of a ureteral J-stent for the evaluation of biodegradable tubular constructs for tissue reconstruction, and the regeneration of ureters in Saanen goats. Similarly to a previous study in pigs, the ureteral J-stent was blindly inserted until some resistance was met. During evaluation of the goats after three months, perforation of the renal cortex by the stent was observed in four out of seven animals. These results indicated that blind stent placement was not possible in goats. In four new goats, clinical protocols were followed using X-ray and iodinated contrast fluids to visualize the kidney and stent during stent placement. With this adaptation the stents were successfully placed in the kidneys of these four new goats with minimal additional effort. It is likely that other groups in other fields ran into similar problems that could have been avoided by following clinical protocols. Therefore, we would like to stress the importance of following clinical protocols when using medical devices in animals to prevent unnecessary suffering and to reduce the number of animals needed.

  9. Gas emission during laparoscopic colorectal surgery using a bipolar vessel sealing device: A pilot study on four patients

    Directory of Open Access Journals (Sweden)

    Gianella Michele

    2008-09-01

    Full Text Available Abstract Background Dissection during laparoscopic surgery produces smoke containing potentially toxic substances. The aim of the present study was to analyze smoke samples produced during laparoscopic colon surgery using a bipolar vessel sealing device (LigaSure™. Methods Four consecutive patients undergoing left-sided colectomy were enrolled in this pilot study. Smoke was produced by the use of LigaSure™. Samples (5,5l were evacuated from the pneumoperitoneum in a closed system into a reservoir. Analysis was performed with CO2-laser-based photoacoustic spectroscopy and confirmed by a Fourier-transform infrared spectrum. The detected spectra were compared to the available spectra of known toxins. Results Samples from four laparoscopic sigmoid resections were analyzed. No relevant differences were noted regarding patient and operation characteristics. The gas samples were stable over time proven by congruent control measurements as late as 24 h after sampling. The absorption spectra differed considerably between the patients. One broad absorption line at 100 ppm indicating H2O and several unknown molecules were detected. With a sensitivity of alpha min ca 10-5 cm-1 no known toxic substances like phenol or indole were identified. Conclusion The use of a vessel sealing device during laparoscopic surgery does not produce known toxic substances in relevant quantity. Further studies are needed to identify unknown molecules and to analyze gas emission under various conditions.

  10. Estimation of body composition depends on applied device in patients undergoing major abdominal surgery

    NARCIS (Netherlands)

    Haverkort, Elizabeth B.; Binnekade, Jan M.; de van der Schueren, Marian A. E.; Gouma, Dirk J.; de Haan, Rob J.

    2015-01-01

    Bioelectrical impedance analysis (BIA) is a method used to estimate body compartments such as fat-free mass (FFM) and fat mass (FM). Two BIA devices, a single-frequency BIA (SF-BIA) device and a bioimpedance spectroscopy (BIS) approach, were compared to evaluate their reliability and to study

  11. Estimation of Body Composition Depends on Applied Device in Patients Undergoing Major Abdominal Surgery

    NARCIS (Netherlands)

    Haverkort, E.B.; Binnekade, J.M.; van Bokhorst-de van der Schueren, M.A.E.; Gouma, D.J.; de Haan, R.J.

    2015-01-01

    Background: Bioelectrical impedance analysis (BIA) is a method used to estimate body compartments such as fat-free mass (FFM) and fat mass (FM). Two BIA devices, a single-frequency BIA (SF-BIA) device and a bioimpedance spectroscopy (BIS) approach, were compared to evaluate their reliability and to

  12. Use of piezosurgery device in management of oral surgery complications: clincal case and clinical experience report.

    Science.gov (United States)

    Sammartino, G; Riccitiello, F; Trosino, O; Marenzi, G; Cioffi, A; Mortellaro, C

    2012-05-01

    The root displacement into the maxillary sinus could be a complication of oral surgery in the upper jaw. In these cases, the root removal is needed in order to avoid the occurrence of sinus pathologies. Piezosurgery techniques could assure a safer management of such complications, because of the clear surgical visibility and the selective ability of cut. The aim of this article is to present a case of oral surgery complication (root displacement in the right maxillary sinus), in which piezosurgery technique helped for a correct and safe clinical management, allowing to reduce the soft tissue damage.

  13. Novel Na(+) doped Alq3 hybrid materials for organic light-emitting diode (OLED) devices and flat panel displays.

    Science.gov (United States)

    Bhagat, S A; Borghate, S V; Kalyani, N Thejo; Dhoble, S J

    2015-05-01

    Pure and Na(+) -doped Alq3 complexes were synthesized by a simple precipitation method at room temperature, maintaining a stoichiometric ratio. These complexes were characterized by X-ray diffraction, Fourier transform infrared (FTIR), UV/Vis absorption and photoluminescence (PL) spectra. The X-ray diffractogram exhibits well-resolved peaks, revealing the crystalline nature of the synthesized complexes, FTIR confirms the molecular structure and the completion of quinoline ring formation in the metal complex. UV/Vis absorption and PL spectra of sodium-doped Alq3 complexes exhibit high emission intensity in comparison with Alq3 phosphor, proving that when doped in Alq3 , Na(+) enhances PL emission intensity. The excitation spectra of the synthesized complexes lie in the range 242-457 nm when weak shoulders are also considered. Because the sharp excitation peak falls in the blue region of visible radiation, the complexes can be employed for blue chip excitation. The emission wavelength of all the synthesized complexes lies in the bluish green/green region ranging between 485 and 531 nm. The intensity of the emission wavelength was found to be elevated when Na(+) is doped into Alq3 . Because both the excitation and emission wavelengths fall in the visible region of electromagnetic radiation, these phosphors can also be employed to improve the power conversion efficiency of photovoltaic cells by using the solar spectral conversion principle. Thus, the synthesized phosphors can be used as bluish green/green light-emitting phosphors for organic light-emitting diodes, flat panel displays, solid-state lighting technology - a step towards the desire to reduce energy consumption and generate pollution free light. Copyright © 2014 John Wiley & Sons, Ltd.

  14. Development and control of a magnetorheological haptic device for robot assisted surgery.

    Science.gov (United States)

    Shokrollahi, Elnaz; Goldenberg, Andrew A; Drake, James M; Eastwood, Kyle W; Kang, Matthew

    2017-07-01

    A prototype magnetorheological (MR) fluid-based actuator has been designed for tele-robotic surgical applications. This device is capable of generating forces up to 47 N, with input currents ranging from 0 to 1.5 A. We begin by outlining the physical design of the device, and then discuss a novel nonlinear model of the device's behavior. The model was developed using the Hammerstein-Wiener (H-W) nonlinear black-box technique and is intended to accurately capture the hysteresis behavior of the MR-fluid. Several experiments were conducted on the device to collect estimation and validation datasets to construct the model and assess its performance. Different estimating functions were used to construct the model, and their effectiveness is assessed based on goodness-of-fit and final-prediction-error measurements. A sigmoid network was found to have a goodness-of-fit of 95%. The model estimate was then used to tune a PID controller. Two control schemes were proposed to eliminate the hysteresis behavior present in the MR fluid device. One method uses a traditional force feedback control loop and the other is based on measuring the magnetic field using a Hall-effect sensor embedded within the device. The Hall-effect sensor scheme was found to be superior in terms of cost, simplicity and real-time control performance compared to the force control strategy.

  15. Impact of tricuspid valve surgery at the time of left ventricular assist device insertion on postoperative outcomes.

    Science.gov (United States)

    Dunlay, Shannon M; Deo, Salil V; Park, Soon J

    2015-01-01

    Tricuspid regurgitation (TR) is common in patients with heart failure undergoing left ventricular assist device (LVAD) implantation. Whether the TR should be surgically managed at the time of LVAD surgery is controversial. We searched SCOPUS, Web of Science, Ovid EMBASE, and Ovid MEDLINE (through May 10, 2014) for randomized controlled trials and observational studies comparing postoperative outcomes in patients treated with LVAD with concomitant tricuspid valve surgery (TVS) compared with LVAD alone. Six observational studies including 3,249 patients compared outcomes following LVAD + TVS versus LVAD. Four studies were single-center and most did not adjust for potential confounders. Addition of TVS prolonged cardiopulmonary bypass times by an average of 31 minutes (three studies, 95% CI 20-42). There was no difference in need for right ventricular assist device (six studies, HR 1.42, 95% CI 0.54-3.76), acute renal failure (four studies, HR 1.07, 95% CI 0.55-2.10), or early mortality (six studies, HR 1.28, 95% CI 0.78-2.08) in patients treated with LVAD + TVS versus LVAD alone. TVS prolongs cardiopulmonary bypass times, but available data demonstrate no significant association with early postoperative outcomes. However, differences in baseline risk of patients treated with TVS versus not limit our ability to draw conclusions.

  16. Comparison of cost-effectiveness and postoperative outcome of device closure and open surgery closure techniques for treatment of patent ductus arteriosus

    Directory of Open Access Journals (Sweden)

    Alireza Ahmadi

    2014-01-01

    Full Text Available BACKGROUND: Various devices have been recently employed for percutaneous closure of the patent ductus arteriosus (PDA. Although the high effectiveness of device closure techniques has been clearly determined, a few studies have focused on the cost-effectiveness and also postoperative complications of these procedures in comparison with open surgery. The present study aimed to evaluate the clinical outcome and cost-effectiveness of PDA occlusion by Amplatzer and coil device in comparisong with open surgery. METHODS: In this cross-sectional study, a randomized sample of 201 patients aged 1 month to 16 years (105 patients with device closure and 96 patients with surgical closure was selected. The ratio of total pulmonary blood flow to total systemic blood flow, the Qp/Qs ratio, was measured using a pulmonary artery catheter. The cost analysis included direct medical care costs associated with device implantation and open surgery, as well as professional fees. All costs were calculated in Iranian Rials and then converted to US dollars. RESULTS: There was no statistical difference in mean Qp/Qs ratio before the procedure between the device closure group and the open surgery group (2.1 ± 0.7 versus 1.7 ± 0.6, P = 0.090. The mean measured costs were overall higher in the device closure group than in open closure group (948.87 ± 548.76 US$ versus 743.70 ± 696.91 US$, P < 0.001. This difference remained significant after adjustment for age and gender (Standardized Beta = 0.160, P = 0.031. PDA closure with the Amplatzer ductal occluder (1053.05 ± 525.73 US$ or with Nit-Occlud coils (PFM (912.73 ± 565.94 US$, P < 0.001 was more expensive than that via open surgery. However, the Cook detachable spring coils device closure (605.65 ± 194.62 US$, P = 0.650 had a non-significant cost difference with open surgery. No event was observed in the device closure group regarding in-hospital mortality or morbidity; however, in another group, 2 in-hospital deaths

  17. Mobile Device Trends in Orthopedic Surgery: Rapid Change and Future Implications.

    Science.gov (United States)

    Andrawis, John P; Muzykewicz, David A; Franko, Orrin I

    2016-01-01

    Mobile devices are increasingly becoming integral communication and clinical tools. Monitoring the prevalence and utilization characteristics of surgeons and trainees is critical to understanding how these new technologies can be best used in practice. The authors conducted a prospective Internet-based survey over 7 time points from August 2010 to August 2014 at all nationwide American Council for Graduate Medical Education-accredited orthopedic programs. The survey questionnaire was designed to evaluate the use of devices and mobile applications (apps) among trainees and physicians in the clinical setting. Results were analyzed and summarized for orthopedic surgeons and trainees. During the 48-month period, there were 7 time points with 467, 622, 329, 223, 237, 111, and 134 responses. Mobile device use in the clinical setting increased across all fields and levels of training during the study period. Orthopedic trainees increased their use of Smartphone apps in the clinical setting from 60% to 84%, whereas attending use increased from 41% to 61%. During this time frame, use of Apple/Android platforms increased from 45%/13% to 85%/15%, respectively. At all time points, 70% of orthopedic surgeons believed their institution/hospital should support mobile device use. As measured over a 48-month period, mobile devices have become an ubiquitous tool in the clinical setting among orthopedic surgeons and trainees. The authors expect these trends to continue and encourage providers and trainees to be aware of the limitations and risks inherent with new technology. Copyright 2016, SLACK Incorporated.

  18. Design of a 7-DOF haptic master using a magneto-rheological devices for robot surgery

    Science.gov (United States)

    Kang, Seok-Rae; Choi, Seung-Bok; Hwang, Yong-Hoon; Cha, Seung-Woo

    2017-04-01

    This paper presents a 7 degrees-of-freedom (7-DOF) haptic master which is applicable to the robot-assisted minimally invasive surgery (RMIS). By utilizing a controllable magneto-rheological (MR) fluid, the haptic master can provide force information to the surgeon during surgery. The proposed haptic master consists of three degrees motions of X, Y, Z and four degrees motions of the pitch, yaw, roll and grasping. All of them have force feedback capability. The proposed haptic master can generate the repulsive forces or torques by activating MR clutch and MR brake. Both MR clutch and MR brake are designed and manufactured with consideration of the size and output torque which is usable to the robotic surgery. A proportional-integral-derivative (PID) controller is then designed and implemented to achieve torque/force tracking trajectories. It is verified that the proposed haptic master can track well the desired torque and force occurred in the surgical place by controlling the input current applied to MR clutch and brake.

  19. Trends in the Management of Patients With Left Ventricular Assist Devices Presenting for Noncardiac Surgery: A 10-Year Institutional Experience.

    Science.gov (United States)

    Stone, Marc; Hinchey, Joseph; Sattler, Christopher; Evans, Adam

    2016-09-01

    In our institution, the vast majority of patients presenting for noncardiac surgery (NCS) while supported by a left ventricular assist device (LVAD) are now cared for by noncardiac-trained anesthesiologists as the result of a decade of educational intervention to effect this transition. This represents a significant departure from the published experiences of other institutions. With institutional review board approval, we queried the database of our anesthesia record keeping system (CompuRecord) to determine various aspects of the perioperative management of these patients from July 1, 2003, through June 30, 2013, during which time 271 NCS procedures were performed on adult patients supported by LVADs. Over the entire study period (2003-2013), anesthetic care was provided by a cardiac anesthesiologist 47% of the time and by a noncardiac anesthesiologist 53% of the time. However, by the time period 2012-2013, 88% of the NCS procedures were staffed by a noncardiac anesthesiologist. Despite the prevalence of continuous flow devices in this series, the use of invasive blood pressure monitoring decreased dramatically by the later years of the study. Vasoactive and inotropic medications were rarely required intraoperatively. No intraoperative cardiac arrests, thromboembolic complications, or device malfunctions occurred. Our conclusion is that NCS procedures on LVAD-supported patients can be safely managed by educated noncardiac anesthesiologists. © The Author(s) 2015.

  20. Transsphenoidal surgery assisted by a new guidance device: results of a series of 747 cases.

    Science.gov (United States)

    Tao, Yang; Jian-wen, Gu; Yong-qin, Kuang; Li-bin, Yang; Hai-dong, Huang; Wen-tao, Yang; Xue-min, Xing

    2011-10-01

    The objective of this study is to report the efficacy and safety of microsurgical transsphenoidal surgery using a frame for sella guidance in a series of patients with untreated pituitary adenoma. In this study, seven hundred and forty-seven patients undergoing transsphenoidal resection of a pituitary adenoma involving use of the frame were included. Follow-up of twelve to one hundred months was performed in all patients. During the procedures using the frame, pituitary adenomas were fully exposed, and no cavernous sinus haemorrhage due to anteroposterior displacement or internal carotid artery lesion due to right-and-left deviation occurred. The duration of the surgical procedure ranged from 28 min to 87 min with a mean of 44 min. The most frequent tumour type was prolactin-secreting adenoma (32.4%), followed by clinically non-functioning adenoma (NFPA) (28.5%), growth hormone-secreting adenoma (25.0%), and adrenocorticotropin-secreting adenoma (13.7%). Normalisation of visual defects occurred in 226 (42.2%) of the 535 patients with visual disturbances. Normalisation of hormone occurred in 458 of 551 patients with endocrine-active tumour in the follow-up period. Two patients died as a consequence of surgery. The endonasal transsphenoidal technique is a safe, quick, and effective approach to pituitary adenomas. Our guidance frame allows the surgeon to open and close the wound rapidly, which avoids trajectory deviation and shortens the duration of the surgical procedure. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. P-shaped Coiled Stator Ultrasound Motor for Rotating Intravascular Surgery Device

    Directory of Open Access Journals (Sweden)

    Toshinobu ABE

    2015-01-01

    Full Text Available The primary focus of this paper is the development of an ultra-miniature ultrasound motor for use in the human blood vessel. Since the size of the drive source for rotating the atherectomy device and intravascular ultrasonography system are large currently in practical use, it is installed outside the body, and the rotational power for the atherectomy device and intravascular ultrasonography system are transmitted through the long tortuous blood vessel. Such systems suffer from the problem that the rotation becomes non-uniform, and the problem that the available time is limited. We have therefore developed a P-shaped coiled stator ultrasound motor as a miniature ultrasound motor for rotating the ultrasound sensor for use in blood vessels in order to solve these problems. In this paper, we describe measurement of the torque, revolution speed, output power, efficiency, and particle motion on acoustic waveguide of the P-shaped coiled stator ultrasound motor.

  2. Comparison of cost-effectiveness and postoperative outcome of device closure and open surgery closure techniques for treatment of patent ductus arteriosus.

    Science.gov (United States)

    Ahmadi, Alireza; Sabri, Mohammadreza; Bigdelian, Hamid; Dehghan, Bahar; Gharipour, Mojgan

    2014-01-01

    Various devices have been recently employed for percutaneous closure of the patent ductus arteriosus (PDA). Although the high effectiveness of device closure techniques has been clearly determined, a few studies have focused on the cost-effectiveness and also postoperative complications of these procedures in comparison with open surgery. The present study aimed to evaluate the clinical outcome and cost-effectiveness of PDA occlusion by Amplatzer and coil device in comparisong with open surgery. In this cross-sectional study, a randomized sample of 201 patients aged 1 month to 16 years (105 patients with device closure and 96 patients with surgical closure) was selected. The ratio of total pulmonary blood flow to total systemic blood flow, the Qp/Qs ratio, was measured using a pulmonary artery catheter. The cost analysis included direct medical care costs associated with device implantation and open surgery, as well as professional fees. All costs were calculated in Iranian Rials and then converted to US dollars. There was no statistical difference in mean Qp/Qs ratio before the procedure between the device closure group and the open surgery group (2.1 ± 0.7 versus 1.7 ± 0.6, P = 0.090). The mean measured costs were overall higher in the device closure group than in open closure group (948.87 ± 548.76 US$ versus 743.70 ± 696.91 US$, P gender (Standardized Beta = 0.160, P = 0.031). PDA closure with the Amplatzer ductal occluder (1053.05 ± 525.73 US$) or with Nit-Occlud coils (PFM) (912.73 ± 565.94 US$, P < 0.001) was more expensive than that via open surgery. However, the Cook detachable spring coils device closure (605.65 ± 194.62 US$, P = 0.650) had a non-significant cost difference with open surgery. No event was observed in the device closure group regarding in-hospital mortality or morbidity; however, in another group, 2 in-hospital deaths occurred, two patients experienced pneumonia and seizure, and one suffered electrolyte abnormalities including

  3. 78 FR 29672 - Cardiovascular Devices; Reclassification of External Counter-Pulsating Devices for Treatment of...

    Science.gov (United States)

    2013-05-21

    .... FDA-2013-N-0487] Cardiovascular Devices; Reclassification of External Counter- Pulsating Devices for... proposed rule (44 FR 13426, March 9, 1979), the Cardiovascular Device Classification Panel (the 1979 Panel... of Subjects in 21 CFR Part 870 Medical devices, Cardiovascular devices...

  4. Preliminary experience with a new device for delayed sternal closure strategy in cardiac surgery.

    Science.gov (United States)

    Santini, Francesco; Onorati, Francesco; Telesca, Mariassunta; Faggian, Giuseppe; Mazzucco, Alessandro

    2012-06-01

    Open chest management with delayed sternal closure (DSC) is a valuable strategy in the management of patients with postcardiotomy hemodynamic instability or severe coagulopathy. The conventional extemporized material available for off-label sternal stenting however may limit its efficacy. We evaluated outcomes of patients with refractory severe postcardiotomy cardiogenic shock (SPCCS) treated with DSC using a novel temporary sternal spreader (NTSS) which allows myocardial recovery by progressive controlled approximation of the sternal edges. Seven patients (4 male, mean age 66.5 ± 5 years) with refractory SPCCS showing acute hemodynamic instability at sternal closure, were implanted with the NTSS, consisting of stainless-steel branches linked to 2 diverging plates of polyether-ether ketone, whose progressive opening/closing mechanism can be controlled from outside the chest with a rotating steel wire. The sternal wound was closed by an elastic membrane to achieve a sterile field. Swan-Ganz monitoring was employed, and clinical outcomes evaluated. The device was successfully implanted in all patients without device-related complications or failures. Progressive approximation of sternal edges, titrated on cardiac index values, was successfully completed allowing subsequent uneventful sternal closure in all. Mean time from SPCCS to sternal closure was 70 ± 21 hours. No patient developed infective complications or late hemodynamic instability after device removal and sternal closure. One patient (14%) died of multiorgan failure on postoperative day 9. Despite the limited number of patients enrolled, the NTSS proved safe and effective in allowing complete myocardial recovery after SPCCS, avoiding hemodynamic instability related to abrupt sternal closure, with no occurrence of infective complications.

  5. Volume CT with a flat-panel detector on a mobile, isocentric C-arm: Pre-clinical investigation in guidance of minimally invasive surgery

    International Nuclear Information System (INIS)

    Siewerdsen, J.H.; Moseley, D.J.; Burch, S.; Bisland, S.K.; Bogaards, A.; Wilson, B.C.; Jaffray, D.A.

    2005-01-01

    A mobile isocentric C-arm (Siemens PowerMobil) has been modified in our laboratory to include a large area flat-panel detector (in place of the x-ray image intensifier), providing multi-mode fluoroscopy and cone-beam computed tomography (CT) imaging capability. This platform represents a promising technology for minimally invasive, image-guided surgical procedures where precision in the placement of interventional tools with respect to bony and soft-tissue structures is critical. The image quality and performance in surgical guidance was investigated in pre-clinical evaluation in image-guided spinal surgery. The control, acquisition, and reconstruction system are described. The reproducibility of geometric calibration, essential to achieving high three-dimensional (3D) image quality, is tested over extended time scales (7 months) and across a broad range in C-arm angulation (up to 45 deg.), quantifying the effect of improper calibration on spatial resolution, soft-tissue visibility, and image artifacts. Phantom studies were performed to investigate the precision of 3D localization (viz., fiber optic probes within a vertebral body) and effect of lateral projection truncation (limited field of view) on soft-tissue detectability in image reconstructions. Pre-clinical investigation was undertaken in a specific spinal procedure (photodynamic therapy of spinal metastases) in five animal subjects (pigs). In each procedure, placement of fiber optic catheters in two vertebrae (L1 and L2) was guided by fluoroscopy and cone-beam CT. Experience across five procedures is reported, focusing on 3D image quality, the effects of respiratory motion, limited field of view, reconstruction filter, and imaging dose. Overall, the intraoperative cone-beam CT images were sufficient for guidance of needles and catheters with respect to bony anatomy and improved surgical performance and confidence through 3D visualization and verification of transpedicular trajectories and tool placement

  6. A wound retraction device for laparoscopic-assisted intestinal surgery in dogs and cats.

    Science.gov (United States)

    Gower, Sara B; Mayhew, Philipp D

    2011-06-01

    To report experience with laparoscopic-assisted intestinal resection and anastomosis for treatment of discrete intestinal masses using a novel wound retraction device. Case series. Dogs (n=2) and cats (6). Dogs and cats with discrete intestinal masses identified by ultrasonography without evidence of intestinal perforation or peritonitis, were included. A 2 portal technique was used; 1 portal was enlarged for insertion of the wound retraction device through which the intestine was examined as thoroughly as possible. The diseased portion of the intestine was exteriorized through the wound retractor and resection and anastomosis of the intestinal mass performed. Of the 8 animals, laparoscopic-assisted intestinal resection and anastomosis through the wound retractor was performed in 2 dogs and 3 cats. In 3 cats, based on either location or extent of the lesion, 2 were converted to laparoscopic-assisted intestinal biopsies and 1 to an open colocolostomy. No other intra- or perioperative complications were encountered and all animals survived to discharge. Laparoscopic-assisted intestinal resection and anastomosis can be performed in select canine and feline patients with modestly sized, discrete intestinal masses. © Copyright 2011 by The American College of Veterinary Surgeons.

  7. Combined Scleral Flap with Donor Scleral Patch Graft for Anterior Tube Placement in Glaucoma Drainage Device Surgery

    Directory of Open Access Journals (Sweden)

    Jea H. Yu

    2016-01-01

    Full Text Available Purpose. To report a new technique for anterior placement of tubes for glaucoma drainage devices to reduce the risk of tube erosions. Methods. Retrospective review of select cases of Ahmed Valve surgery combined with the novel method of a limbal-based scleral flap covered by a scleral patch graft to cover the tube at the entrance through the limbus. Intraoperative and postoperative illustrations are shown to highlight the method of tube placement. Results. In this retrospective case series, 3 patients are presented illustrating the technique. Two had neovascular glaucoma and one had primary open-angle glaucoma (POAG. On average, intraocular pressure was reduced from 39±14 mmHg to 15±2 mmHg and the number of glaucoma medications was reduced from 4±1 to 0. Preoperative and most recent visual acuities were hand-motion (HM and HM, 20/60 and 20/50, and 20/70 and 20/30, respectively. Conclusion. The combination of a limbal-based scleral flap with scleral patch graft to cover the tube with glaucoma drainage devices may be an effective means to reduce erosion and protect against endophthalmitis.

  8. Combined Scleral Flap with Donor Scleral Patch Graft for Anterior Tube Placement in Glaucoma Drainage Device Surgery.

    Science.gov (United States)

    Yu, Jea H; Nguyen, Chuck; Gallemore, Esmeralda; Gallemore, Ron P

    2016-01-01

    Purpose . To report a new technique for anterior placement of tubes for glaucoma drainage devices to reduce the risk of tube erosions. Methods . Retrospective review of select cases of Ahmed Valve surgery combined with the novel method of a limbal-based scleral flap covered by a scleral patch graft to cover the tube at the entrance through the limbus. Intraoperative and postoperative illustrations are shown to highlight the method of tube placement. Results . In this retrospective case series, 3 patients are presented illustrating the technique. Two had neovascular glaucoma and one had primary open-angle glaucoma (POAG). On average, intraocular pressure was reduced from 39 ± 14 mmHg to 15 ± 2 mmHg and the number of glaucoma medications was reduced from 4 ± 1 to 0. Preoperative and most recent visual acuities were hand-motion (HM) and HM, 20/60 and 20/50, and 20/70 and 20/30, respectively. Conclusion . The combination of a limbal-based scleral flap with scleral patch graft to cover the tube with glaucoma drainage devices may be an effective means to reduce erosion and protect against endophthalmitis.

  9. Panel Analysis

    DEFF Research Database (Denmark)

    Brænder, Morten; Andersen, Lotte Bøgh

    2014-01-01

    Based on our 2013-article, ”Does Deployment to War Affect Soldiers' Public Service Motivation – A Panel Study of Soldiers Before and After their Service in Afghanistan”, we present Panel Analysis as a methodological discipline. Panels consist of multiple units of analysis, observed at two or more...... in research settings where it is not possible to distribute units of analysis randomly or where the independent variables cannot be manipulated. The greatest disadvantage in regard to using panel studies is that data may be difficult to obtain. This is most clearly vivid in regard to the use of panel surveys...... points in time. In comparison with traditional cross-sectional studies, the advantage of using panel studies is that the time dimension enables us to study effects. Whereas experimental designs may have a clear advantage in regard to causal inference, the strength of panel studies is difficult to match...

  10. Biodegradable device applied in flatfoot surgery: Comparative studies between clinical and technological aspects of removed screws

    International Nuclear Information System (INIS)

    Ruozi, Barbara; Belletti, Daniela; Manfredini, Giuseppe; Tonelli, Massimo; Sena, Paola; Vandelli, Maria Angela; Forni, Flavio; Tosi, Giovanni

    2013-01-01

    Poly-L-lactide (PLLA) is one of the most used polymers for biomedical application; its use in sutures and other implants has been widely investigated. Although the knowledge of PLLA biodegradation and biocompatibility features is deep, PLLA screws used to correct the flat foot deformity have deserved attention since they are not degraded in most of cases after a long period of years (3–7) from the implantation. In this article, a clinical and radiological evaluation (NMR, histological and clinical outcomes) on patients was correlated with physico-chemical characterization (by SEM, DSC, GPC and XRD analysis at different temperatures) on both native and patient-recovered screws together with the theoretical degradation processes of PLLA-based implants. The data demonstrated the need for crossing the biodegradation and bioabsorption of the polymer with the characteristics of both the device (geometry, structure and fabrication process) and the implantation site. Highlights: ► Resorbable PLLA screws were proposed for arthroereisis in pediatric flatfoot. ► Satisfactory clinical results were obtained almost in the totality of patients. ► The bioabsorption period is slightly longer than what is expected. ► Patient-recovered screws were analyzed to evaluate the biodegradation stage. ► Degradability/structural integrity during implantation should be ameliorated

  11. A Potential Solution to Minimally Invasive Device for Oral Surgery: Evaluation of Surgical Outcomes in Rat

    Directory of Open Access Journals (Sweden)

    Keng-Liang Ou

    2015-01-01

    Full Text Available The objective of the present research was to investigate the thermal injury in the brain after minimally invasive electrosurgery using instruments with copper-doped diamond-like carbon (DLC-Cu surface coating. The surface morphologies of DLC-Cu thin films were characterized using scanning electron microscopy and atomic force microscopy. Three-dimensional brain models were reconstructed using magnetic resonance imaging to simulate the electrosurgical operation. In adult rats, a monopolar electrosurgical instrument coated with the DLC-Cu thin film was used to generate lesions in the brain. Animals were sacrificed for evaluations on postoperative days 0, 2, 7, and 28. Data indicated that the temperature decreased significantly when minimally invasive electrosurgical instruments with nanostructure DLC-Cu thin films were used and continued to decrease with increasing film thickness. On the other hand, the DLC-Cu-treated device created a relatively small thermal injury area and lateral thermal effect in the brain tissues. These results indicated that the DLC-Cu thin film minimized excessive thermal injury and uniformly distributed the temperature in the brain. Taken together, our study results suggest that the DLC-Cu film on copper electrode substrates is an effective means for improving the performance of electrosurgical instruments.

  12. Biodegradable device applied in flatfoot surgery: Comparative studies between clinical and technological aspects of removed screws

    Energy Technology Data Exchange (ETDEWEB)

    Ruozi, Barbara, E-mail: barbara.ruozi@unimore.it [Department of Life Sciences, University of Modena and Reggio Emilia, Via Campi 183, 41100 Modena, MO (Italy); Belletti, Daniela, E-mail: daniela.belletti@unimore.it [Department of Life Sciences, University of Modena and Reggio Emilia, Via Campi 183, 41100 Modena, MO (Italy); Manfredini, Giuseppe, E-mail: giuseppe626@virgilio.it [Orthopaedic and Traumatologic Clinic, University Hospital of Modena and Reggio Emilia, Modena Italy, Director Prof. F. Catani, Via del Pozzo 71, Policlinico, 41100 Modena, MO (Italy); Tonelli, Massimo, E-mail: massimo.tonelli@unimore.it [CIGS, University of Modena and Reggio Emilia, Via Campi 213/A, 41100 Modena, MO (Italy); Sena, Paola, E-mail: paola.sena@unimore.it [Department of Biomedical, Metabolic and Neural Sciences, University of Modena and Reggio Emilia, Via del Pozzo 71, Policlinico, 41100 Modena, MO (Italy); Vandelli, Maria Angela, E-mail: mariaangela.vandelli@unimore.it [Department of Life Sciences, University of Modena and Reggio Emilia, Via Campi 183, 41100 Modena, MO (Italy); Forni, Flavio, E-mail: flavio.forni@unimore.it [Department of Life Sciences, University of Modena and Reggio Emilia, Via Campi 183, 41100 Modena, MO (Italy); Tosi, Giovanni, E-mail: giovanni.tosi@unimore.it [Department of Life Sciences, University of Modena and Reggio Emilia, Via Campi 183, 41100 Modena, MO (Italy)

    2013-04-01

    Poly-L-lactide (PLLA) is one of the most used polymers for biomedical application; its use in sutures and other implants has been widely investigated. Although the knowledge of PLLA biodegradation and biocompatibility features is deep, PLLA screws used to correct the flat foot deformity have deserved attention since they are not degraded in most of cases after a long period of years (3–7) from the implantation. In this article, a clinical and radiological evaluation (NMR, histological and clinical outcomes) on patients was correlated with physico-chemical characterization (by SEM, DSC, GPC and XRD analysis at different temperatures) on both native and patient-recovered screws together with the theoretical degradation processes of PLLA-based implants. The data demonstrated the need for crossing the biodegradation and bioabsorption of the polymer with the characteristics of both the device (geometry, structure and fabrication process) and the implantation site. Highlights: ► Resorbable PLLA screws were proposed for arthroereisis in pediatric flatfoot. ► Satisfactory clinical results were obtained almost in the totality of patients. ► The bioabsorption period is slightly longer than what is expected. ► Patient-recovered screws were analyzed to evaluate the biodegradation stage. ► Degradability/structural integrity during implantation should be ameliorated.

  13. Solar panel parallel mounting configuration

    Science.gov (United States)

    Mutschler, Jr., Edward Charles (Inventor)

    1998-01-01

    A spacecraft includes a plurality of solar panels interconnected with a power coupler and an electrically operated device to provide power to the device when the solar cells are insolated. The solar panels are subject to bending distortion when entering or leaving eclipse. Spacecraft attitude disturbances are reduced by mounting each of the solar panels to an elongated boom made from a material with a low coefficient of thermal expansion, so that the bending of one panel is not communicated to the next. The boom may be insulated to reduce its bending during changes in insolation. A particularly advantageous embodiment mounts each panel to the boom with a single mounting, which may be a hinge. The single mounting prevents transfer of bending moments from the panel to the boom.

  14. Safety, efficacy, and intraoperative characteristics of DisCoVisc and Healon ophthalmic viscosurgical devices for cataract surgery

    Directory of Open Access Journals (Sweden)

    Modi SS

    2011-09-01

    Full Text Available Satish S Modi1, James A Davison2, Tom Walters3 1Seeta Eye Centers, Poughkeepsie, NY, USA; 2Wolfe Clinic, Marshalltown, IA, USA; 3Texas Eye Care, Austin, TX, USA Purpose: To evaluate the safety and efficacy of DisCoVisc ophthalmic viscosurgical device (OVD, Alcon Laboratories, Inc with respect to a comparator, Healon OVD (Advanced Medical Optics, Inc. Patients and methods: In this prospective study, patients with cataracts were randomized to an OVD, and then received phacoemulsification and injection of an intraocular lens. After each surgery, unmasked investigators completed subjective questionnaires about OVD characteristics during each stage of the procedure. Masked technicians evaluated objective safety parameters of intraocular pressure (IOP and endothelial cell density, with 90 days of follow-up. Results: The DisCoVisc OVD group (128 eyes and the Healon OVD group (121 eyes had statistically similar outcomes for IOP and for endothelial cell loss. Subjectively assessed viscosity was statistically different (P < 0.0001, with Healon OVD most often rated “cohesive” and DisCoVisc OVD most often rated “both dispersive and cohesive”. Workspace maintenance differed between groups (P < 0.0001, with workspace most frequently rated “full chamber maintained” when using DisCoVisc OVD and most frequently rated “workspace maintained” when using Healon OVD. “Flat” or “shallow” workspace ratings occurred only in the Healon OVD group. Conclusion: DisCoVisc OVD had both cohesive and dispersive properties, and was safe and effective for every stage of cataract surgery. Keywords: cataract, endothelial cell density, viscoelastic, phacoemulsification

  15. Characterizing the Utility and Limitations of Repurposing an Open-Field Optical Imaging Device for Fluorescence-Guided Surgery in Head and Neck Cancer Patients.

    Science.gov (United States)

    Moore, Lindsay S; Rosenthal, Eben L; Chung, Thomas K; de Boer, Esther; Patel, Neel; Prince, Andrew C; Korb, Melissa L; Walsh, Erika M; Young, E Scott; Stevens, Todd M; Withrow, Kirk P; Morlandt, Anthony B; Richman, Joshua S; Carroll, William R; Zinn, Kurt R; Warram, Jason M

    2017-02-01

    The purpose of this study was to assess the potential of U.S. Food and Drug Administration-cleared devices designed for indocyanine green-based perfusion imaging to identify cancer-specific bioconjugates with overlapping excitation and emission wavelengths. Recent clinical trials have demonstrated potential for fluorescence-guided surgery, but the time and cost of the approval process may impede clinical translation. To expedite this translation, we explored the feasibility of repurposing existing optical imaging devices for fluorescence-guided surgery. Consenting patients (n = 15) scheduled for curative resection were enrolled in a clinical trial evaluating the safety and specificity of cetuximab-IRDye800 (NCT01987375). Open-field fluorescence imaging was performed preoperatively and during the surgical resection. Fluorescence intensity was quantified using integrated instrument software, and the tumor-to-background ratio characterized fluorescence contrast. In the preoperative clinic, the open-field device demonstrated potential to guide preoperative mapping of tumor borders, optimize the day of surgery, and identify occult lesions. Intraoperatively, the device demonstrated robust potential to guide surgical resections, as all peak tumor-to-background ratios were greater than 2 (range, 2.2-14.1). Postresection wound bed fluorescence was significantly less than preresection tumor fluorescence (P open-field imaging device was successfully repurposed to distinguish cancer from normal tissue in the preoperative clinic and throughout surgical resection. This study illuminated the potential for existing open-field optical imaging devices with overlapping excitation and emission spectra to be used for fluorescence-guided surgery. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  16. 76 FR 80949 - Request for Nominations for Voting Members on Public Advisory Panels or Committees

    Science.gov (United States)

    2011-12-27

    .... Orthopedic and Rehabilitation Devices Panel. Jamie Waterhouse, Center for Devices Circulatory System Devices... Advisory Committee--Neurosurgeons (cerebrovascular and pediatric), neurologists (stroke, pediatric, pain... ophthalmic clinical trials. Orthopaedic and 2 September 1, 2012. Rehabilitation Devices Panel of the Medical...

  17. Contemporary surgical devices for male stress urinary incontinence: a review of technological advances in current continence surgery.

    Science.gov (United States)

    Chung, Eric

    2017-07-01

    Male stress urinary incontinence (SUI) remains a debilitating condition that adversely impacts all domains of quality of life and is associated with significant social stigma and health economic burden. The incidence of post-prostatectomy urinary incontinence (PPI) depends on the definition of urinary incontinence and the length of patient follow up. In patients with persistent PPI following failure of conservative measures, surgical treatment is recommended although there is no published guideline on when surgery should be performed, and what the best surgical option is. Male slings (MS) can be divided into adjustable or non-adjustable types, and offers an attractive option for patients who wish to avoid mechanical handling during urinary voiding. Published intermediate data supports good safety and efficacy rate in men with mild to moderate degree of SUI. The AMS 800 artificial urinary sphincter (AUS) remains the standard of treatment for complete continence and has the longest efficacy and safety records. Other AUS-like devices are designed to address current AMS 800 limitations but themselves are fraught with their own issues.

  18. Panel Session

    DEFF Research Database (Denmark)

    Bertelsen, Olav Wedege

    2004-01-01

    In this panel session, four researchers will discuss the role of a theoretical foundation, in particular AT, in the design of information technology based artefacts. The general discussion will take of from a specific examination of the ActAD approach.......In this panel session, four researchers will discuss the role of a theoretical foundation, in particular AT, in the design of information technology based artefacts. The general discussion will take of from a specific examination of the ActAD approach....

  19. Hearing improvement with softband and implanted bone-anchored hearing devices and modified implantation surgery in patients with bilateral microtia-atresia.

    Science.gov (United States)

    Wang, Yibei; Fan, Xinmiao; Wang, Pu; Fan, Yue; Chen, Xiaowei

    2018-01-01

    To evaluate auditory development and hearing improvement in patients with bilateral microtia-atresia using softband and implanted bone-anchored hearing devices and to modify the implantation surgery. The subjects were divided into two groups: the softband group (40 infants, 3 months to 2 years old, Ponto softband) and the implanted group (6 patients, 6-28 years old, Ponto). The Infant-Toddler Meaning Auditory Integration Scale was used conducted to evaluate auditory development at baseline and after 3, 6, 12, and 24 months, and visual reinforcement audiometry was used to assess the auditory threshold in the softband group. In the implanted group, bone-anchored hearing devices were implanted combined with the auricular reconstruction surgery, and high-resolution CT was used to assess the deformity preoperatively. Auditory threshold and speech discrimination scores of the patients with implants were measured under the unaided, softband, and implanted conditions. Total Infant-Toddler Meaning Auditory Integration Scale scores in the softband group improved significantly and approached normal levels. The average visual reinforcement audiometry values under the unaided and softband conditions were 76.75 ± 6.05 dB HL and 32.25 ± 6.20 dB HL (P hearing devices is effective for auditory development and hearing improvement in infants with bilateral microtia-atresia. Wearing softband bone-anchored hearing devices before auricle reconstruction and combining bone-anchored hearing device implantation with auricular reconstruction surgery may bethe optimal clinical choice for these patients, and results in more significant hearing improvement and minimal surgical and anesthetic injury. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Lipid Panel

    Science.gov (United States)

    ... A routine cardiac risk assessment typically includes a fasting lipid panel. Beyond that, research continues into the usefulness of other non-traditional markers of cardiac risk, such as Lp-PLA 2 . A health practitioner may choose to evaluate one or more ...

  1. Thermal Analysis of Solar Panels

    Science.gov (United States)

    Barth, Nicolas; de Correia, João Pedro Magalhães; Ahzi, Saïd; Khaleel, Mohammad Ahmed

    In this work, we propose to analyze the thermal behavior of PV panels using finite element simulations (FEM). We applied this analysis to compute the temperature distribution in a PV panel BP 350 subjected to different atmospheric conditions. This analysis takes into account existing formulations in the literature and, based on NOCT conditions, meteorological data was used to validate our approach for different wind speed and solar irradiance. The electrical performance of the PV panel was also studied. The proposed 2D FEM analysis is applied to different region's climates and was also used to consider the role of thermal inertia on the optimization of the PV device efficiency.

  2. State of the art of robotic surgery related to vision: brain and eye applications of newly available devices

    Directory of Open Access Journals (Sweden)

    Nuzzi R

    2018-02-01

    Full Text Available Raffaele Nuzzi, Luca Brusasco Department of Surgical Sciences, Eye Clinic, University of Torino, Turin, Italy Background: Robot-assisted surgery has revolutionized many surgical subspecialties, mainly where procedures have to be performed in confined, difficult to visualize spaces. Despite advances in general surgery and neurosurgery, in vivo application of robotics to ocular surgery is still in its infancy, owing to the particular complexities of microsurgery. The use of robotic assistance and feedback guidance on surgical maneuvers could improve the technical performance of expert surgeons during the initial phase of the learning curve. Evidence acquisition: We analyzed the advantages and disadvantages of surgical robots, as well as the present applications and future outlook of robotics in neurosurgery in brain areas related to vision and ophthalmology. Discussion: Limitations to robotic assistance remain, that need to be overcome before it can be more widely applied in ocular surgery. Conclusion: There is heightened interest in studies documenting computerized systems that filter out hand tremor and optimize speed of movement, control of force, and direction and range of movement. Further research is still needed to validate robot-assisted procedures. Keywords: robotic surgery related to vision, robots, ophthalmological applications of robotics, eye and brain robots, eye robots

  3. Custom made orthotic device for maintaining skull architecture during the postoperative period in infants undergoing craniosynostosis surgery

    Science.gov (United States)

    Gopal, Venu; Ganesh, Praveen; Nagarjuna, Muralidhara; Kumar, Kiran; Shetty, Samarth; Salins, Paul C.

    2015-01-01

    Aim To fabricate a cost effective, indigenous and simple orthotics helmet for post-operative cranial molding in patients with craniosynostosis surgery. Methods We present a case of 15 month old infant with secondary cranial vault deformity. Cranial vault remodeling surgery involving the posterior skull was planned and executed to increase the posterior gap, so that brain growth would be facilitated towards this empty space. Materials such as thermoplastic sponge, thermoplastic ionomer resin sheet, soft sponge and Velcro straps are used to fabricate a cranial orthotics helmet. Results We have successfully used the above materials to fabricate the orthotics helmet for post-operative cranial molding. Conclusion The technique described in this article is simple and cost effective. It can be custom made according to the demands of the surgical technique and the type of synostosis. It favors an individualistic prognosis, and proves worthwhile as every synostosis requires a unique treatment plan. It is an excellent adjuvant to craniosynostosis remodeling surgery. PMID:26258018

  4. The improvement of dry eye after cataract surgery by intraoperative using ophthalmic viscosurgical devices on the surface of cornea

    Science.gov (United States)

    He, Yuan; Li, Jia; Zhu, Jingfen; Jie, Ying; Wang, Ningli; Wang, Jun

    2017-01-01

    Abstract Backgroud: This study aimed to investigate the protective effect of intraoperative used hydroxypropyl methylcellulose (HPMC 2%) on the ocular surface after cataract surgery. Methods: A total of 149 eyes (149 patients) diagnosed with age-related cataract, age 69.19 ± 9.74 years, were enrolled in this prospective, parallel-design, continuous, randomised controlled study. Patients were randomly assigned to receive HPMC 2% (study group) or balanced salt solution (control group) during the surgery to moisturize the cornea surface. The Ocular Surface Disease Index, Schirmer test without topical anesthetics, tear break-up time, and corneal fluorescein staining were assessed preoperatively, 1 day, 1 week, and 1 month after the surgery, respectively. Results: The Schirmer test value of male patients in the study group at 1 week postoperation was higher than that of male patients in the control group (P = .019). For patients diagnosed with dry eye before the surgery, Schirmer test value in the male patients in the study group at 1 month after surgery was higher than that in the male patients in the control group (P = .037). Furthermore, for the cluster of preoperative dry eye patients whose surgical time was longer than median, corneal fluorescein staining of the patients in the study group was superior to that of the patients in the control group (P = .032). Conclusion: Intraoperative use of HPMC 2% on the cornea surface could improve clinical outcomes of tear film and ocular surface health to some degree, especially in the patients diagnosed with dry eye before the surgery, male patients, and patients whose surgical time was relatively longer. PMID:29390284

  5. Panel discussion

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    The panel discussion at the 10th Allianz Forum on 'Technology and Insurance' dealt with the following topics: New technologies: energy conversion (coal, petroleum, natural gas, nuclear energy, solar energy); infrastructure (transport, data processing); basic products (metallic materials, chemical products, pharmaceutical products); integrated products (microprocessors, production line machines) as well as new risks: political; general economic (financing, market structure); insurance-related, dangers to persons and property; reduction of risks. (orig.) [de

  6. State of the art of robotic surgery related to vision: brain and eye applications of newly available devices

    Science.gov (United States)

    Nuzzi, Raffaele

    2018-01-01

    Background Robot-assisted surgery has revolutionized many surgical subspecialties, mainly where procedures have to be performed in confined, difficult to visualize spaces. Despite advances in general surgery and neurosurgery, in vivo application of robotics to ocular surgery is still in its infancy, owing to the particular complexities of microsurgery. The use of robotic assistance and feedback guidance on surgical maneuvers could improve the technical performance of expert surgeons during the initial phase of the learning curve. Evidence acquisition We analyzed the advantages and disadvantages of surgical robots, as well as the present applications and future outlook of robotics in neurosurgery in brain areas related to vision and ophthalmology. Discussion Limitations to robotic assistance remain, that need to be overcome before it can be more widely applied in ocular surgery. Conclusion There is heightened interest in studies documenting computerized systems that filter out hand tremor and optimize speed of movement, control of force, and direction and range of movement. Further research is still needed to validate robot-assisted procedures. PMID:29440943

  7. Use of Internet panels to conduct surveys.

    Science.gov (United States)

    Hays, Ron D; Liu, Honghu; Kapteyn, Arie

    2015-09-01

    The use of Internet panels to collect survey data is increasing because it is cost-effective, enables access to large and diverse samples quickly, takes less time than traditional methods to obtain data for analysis, and the standardization of the data collection process makes studies easy to replicate. A variety of probability-based panels have been created, including Telepanel/CentERpanel, Knowledge Networks (now GFK KnowledgePanel), the American Life Panel, the Longitudinal Internet Studies for the Social Sciences panel, and the Understanding America Study panel. Despite the advantage of having a known denominator (sampling frame), the probability-based Internet panels often have low recruitment participation rates, and some have argued that there is little practical difference between opting out of a probability sample and opting into a nonprobability (convenience) Internet panel. This article provides an overview of both probability-based and convenience panels, discussing potential benefits and cautions for each method, and summarizing the approaches used to weight panel respondents in order to better represent the underlying population. Challenges of using Internet panel data are discussed, including false answers, careless responses, giving the same answer repeatedly, getting multiple surveys from the same respondent, and panelists being members of multiple panels. More is to be learned about Internet panels generally and about Web-based data collection, as well as how to evaluate data collected using mobile devices and social-media platforms.

  8. Analysis of 3-panel and 4-panel microscale ionization sources

    International Nuclear Information System (INIS)

    Natarajan, Srividya; Parker, Charles B.; Glass, Jeffrey T.; Piascik, Jeffrey R.; Gilchrist, Kristin H.; Stoner, Brian R.

    2010-01-01

    Two designs of a microscale electron ionization (EI) source are analyzed herein: a 3-panel design and a 4-panel design. Devices were fabricated using microelectromechanical systems technology. Field emission from carbon nanotube provided the electrons for the EI source. Ion currents were measured for helium, nitrogen, and xenon at pressures ranging from 10 -4 to 0.1 Torr. A comparison of the performance of both designs is presented. The 4-panel microion source showed a 10x improvement in performance compared to the 3-panel device. An analysis of the various factors affecting the performance of the microion sources is also presented. SIMION, an electron and ion optics software, was coupled with experimental measurements to analyze the ion current results. The electron current contributing to ionization and the ion collection efficiency are believed to be the primary factors responsible for the higher efficiency of the 4-panel microion source. Other improvements in device design that could lead to higher ion source efficiency in the future are also discussed. These microscale ion sources are expected to find application as stand alone ion sources as well as in miniature mass spectrometers.

  9. Modified Descemet’s Stripping Automated Endothelial Keratoplasty: The Use of Ophthalmic Viscoelastic Devices in Hypotonic Eyes That Had Undergone Glaucoma Filtering Surgeries

    Directory of Open Access Journals (Sweden)

    Itaru Oyakawa

    2018-01-01

    Full Text Available Purpose. Descemet’s stripping automated endothelial keratoplasty (DSAEK is more difficult in hypotonic eyes with filtering bleb, due to the difficulties in elevating the intraocular pressure (IOP. We report a new method that uses ophthalmic viscoelastic devices (OVDs to achieve good graft adhesion. Case Presentation. We performed modified DSAEK surgery on 2 eyes of 2 patients, who had previously undergone a trabeculectomy. Both eyes had functioning filtering blebs; the IOP was lower than 10 mmHg without medication. After the graft was inserted into the anterior chamber, the conjunctiva was penetrated, apart from the bleb, using a 30 G needle, and Healon V® was injected into the bleb until the encapsulated space was filled completely. Air was subsequently injected into the anterior chamber to promote the graft attachment to the back surface of the cornea. The IOP was elevated above 40 mmHg in both eyes 1 h after surgery and then decreased to less than 30 mmHg over the subsequent 3 h period. The implanted graft showed good adhesion and no dislocation. Conclusions. Our novel DSAEK procedure that adds one step of OVD injection into the filtering bleb may be useful for hypotonic eyes that had undergone filtering surgeries.

  10. Panel surveys

    OpenAIRE

    MADRE, JL; ZUMKELLER, D; CHLOND, B; ARMOOGUM, J

    2004-01-01

    l'analyse du comportement humain constitue un enjeu important dans le domaine des transports, lequel se transforme radicalement sous la pression des évolutions économique, écologique et démographique. les premières grandes études ont commence il y a plus d'une dizaine d'années : parc auto sofres en france, puget sound panel a seattle. cet article fait le bilan de ces expériences et met en évidence les principaux problèmes méthodologiques rencontres tout en proposant de nouvelles directions d'...

  11. 76 FR 28689 - Microbiology Devices; Classification of In Vitro Diagnostic Device for Bacillus Species Detection

    Science.gov (United States)

    2011-05-18

    .... FDA-2011-N-0103] Microbiology Devices; Classification of In Vitro Diagnostic Device for Bacillus... of the Microbiology Devices Advisory Panel (the Panel). In addition, the proposed rule would... in the Federal Register. 1. Transcript of the FDA Microbiology Devices Panel meeting, March 7, 2002...

  12. Circuits in the Sun: Solar Panel Physics

    Science.gov (United States)

    Gfroerer, Tim

    2013-01-01

    Typical commercial solar panels consist of approximately 60 individual photovoltaic cells connected in series. Since the usual Kirchhoff rules apply, the current is uniform throughout the circuit, while the electric potential of the individual devices is cumulative. Hence, a solar panel is a good analog of a simple resistive series circuit, except…

  13. Combined Laser-Doppler Flowmetry and Spectrophotometry: Feasibility Study of a Novel Device for Monitoring Local Cortical Microcirculation during Aneurysm Surgery.

    Science.gov (United States)

    Sommer, Björn; Kreuzer, Maximilian; Bischoff, Barbara; Wolf, Dennis; Schmitt, Hubert; Eyupoglu, Ilker Y; Rössler, Karl; Buchfelder, Michael; Ganslandt, Oliver; Wiendieck, Kurt

    2017-01-01

    Background  Monitoring of cortical cerebral perfusion is essential, especially in neurovascular surgery. Study Aims  To test a novel noninvasive laser-Doppler flowmetry and spectrophotometry device for feasibility during elective cerebral aneurysm surgery. Material and Methods  In this prospective single-institution nonrandomized trial, we studied local cerebral microcirculation using the noninvasive laser-Doppler spectrophotometer "Oxygen-to-see" (O2C) in 20 consecutive patients (15 female, 5 male; median age: 60.5 ± 11.7 years) who were operated on for incidental cerebral aneurysms. Capillary-venous oxygenation (oxygen saturation ["SO 2 "]), postcapillary venous filling pressures (relative hemoglobin content ["rHb"]), blood cell velocity ("velo"), and blood flow ("flow") were measured in 7-mm tissue depth using a subdural fiberoptic probe. Results  Representative recordings were acquired immediately after dural opening over a median time span of 88 ± 21.8 seconds (range: 60-128 seconds) before surgical manipulation. Baseline values (median ± 2 standard deviations) of brain perfusion as measured with the O2C device were SO 2 , 39 ± 16.6%; rHb, 53 ± 18.6 arbitrary units (AU); velo, 60 ± 20.4 AU; and flow, 311 ± 72.8 AU. Placement of the self-retaining retractor led to a decrease in SO 2 of 17% ± 29% ( p  < .05) and flow of 10% ± 11% ( p  < .01); rHb increased by 18% ± 20% ( p  < .01), and velo remained unchanged. Retractor removal caused the opposite with an increased flow of 10% ± 7% ( p  < 0.001) and velo (3% ± 6%, p  = 0.11), but a decrease in SO 2 of 24% ± 33% ( p  = 0.09) and rHb of 12% ± 20% ( p =0.18). No neurologic or surgical complications occurred. Conclusion  Using this novel noninvasive system, we were able to measure local cerebral microcirculation during aneurysm surgery. Our data indicate that this device is able to detect changes during routine

  14. Design Engineering in Surgery. How to Design, Test and Market Surgical Devices Made With 3D Printing?

    Science.gov (United States)

    Rodríguez García, José Ignacio; Sierra Velasco, José Manuel; Villazón Suárez, Marta; Cabrera Pereira, Ana; Sosa, Valentina; Cortizo Rodríguez, José Luis

    2018-04-01

    Industry 4.0 offers new development opportunities for surgeons. Computer-aided design and 3D printing allow for the creation of prototypes and functional end products. Until now, it was difficult for new devices to get to the manufacturing phase. Nowadays, the main limitations are our creativity, available spaces to test our creations and obtaining financing. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Intravenous sufentanil and morphine for post-cardiac surgery pain relief using patient-controlled analgesia (pca) device: a randomized double-blind clinical trial

    International Nuclear Information System (INIS)

    Alavi, S.M.; Kish, R.F.; Farsad, F.; Imani, F.; Sheikhvatan, M.

    2010-01-01

    Selection of the best analgesic technique in patients undergoing major surgeries can result in lower morbidity and satisfactory postoperative pain relief. In the present study, we tried to compare the effect of morphine and sufentanil on postoperative pain severity and hemodynamic changes by using patient-controlled analgesia (PCA) device in patients who were candidate for coronary artery bypass surgery (CABG). It was a randomized double-blinded clinical trial in which 120 patients aged 30-65 years, ASA physical status I-III, candidate for CABG in Shahid Rajaee hospital in Tehran were included. Before anesthesia, patients were randomly assigned to one of three groups to receive sufentanil (n=40), morphine (n=40) or normal saline (n=40). After tracheal extubation at intensive care unit, PCA was started by, sufentanil 4mg for the first group, morphine 2mg for the second group and normal saline, at same volume for the third group, intravenously with 10 minute lockout interval. Postoperative pain was evaluated by VAS scale, 1, 6, 12, 18 and 24 hours after extubation and systolic blood pressure, arterial oxygen saturation, PCO2 and PO2 were recorded 24 hours after extubation. VAS scores at rest revealed significantly less pain for patients in sufentanil and morphine groups than normal saline group, throughout the twenty-four hours after operation (P<0.001). However, there were no significant differences in the means of VAS scores between sufentanil and morphine groups. Among studied hemodynamic parameters, only systolic blood pressure was reduced more in morphine than sufentanil group (P<0.001). After CABG surgery, administration of intravenous sufentanil and morphine using PCA can lead to similar reduction of postoperative pain severity. (author)

  16. Development of new devices for detection of gastric cancer on laparoscopic surgery using near-infrared light

    Science.gov (United States)

    Inada, Shunko A.; Fuchi, Shingo; Mori, Kensaku; Hasegawa, Junichi; Misawa, Kazunari; Nakanishi, Hayao

    2015-03-01

    In recent year, for the treatment of gastric cancer the laparoscopic surgery is performed, which has good benefits, such as low-burden, low-invasive and the efficacy is equivalent to the open surgery. For identify location of the tumor intraperitoneally for extirpation of the gastric cancer, several points of charcoal ink is injected around the primary tumor. However, in the time of laparoscopic operation, it is difficult to estimate specific site of primary tumor, because the injected charcoal ink diffusely spread to the area distant from the tumor in the stomach. Therefore, a broad area should be resected which results in a great stress for the patients. To overcome this problem, we focused in the near-infrared wavelength of 1000nm band which have high biological transmission. In this study, we developed a fluorescent clip which was realized with glass phosphor (Yb3+, Nd3+ doped to Bi2O3-B2O3 based glasses. λp: 976 nm, FWHM: 100 nm, size: 2x1x3 mm) and the laparoscopic fluorescent detection system for clip-derived near-infrared light. To evaluate clinical performance of a fluorescent clip and the laparoscopic fluorescent detection system, we used resected stomach (thickness: 13 mm) from the patients. Fluorescent clip was fixed on the gastric mucosa, and an excitation light (λ: 808 nm) was irradiated from outside of stomach for detection of fluorescence through stomach wall. As a result, fluorescence emission from the clip was successfully detected. Furthermore, we confirmed that detection sensitivity of the emission of fluorescence from the clip depends on the output power of the excitation light. We conformed that the fluorescent clip in combination with laparoscopic fluorescent detection system is very useful method to identify the exact location of the primary gastric cancer.

  17. Visualizing Macular Structures During Membrane Peeling Surgery With an Intraoperative Spectral-Domain Optical Coherence Tomography Device.

    Science.gov (United States)

    Leisser, Christoph; Hackl, Christoph; Hirnschall, Nino; Luft, Nikolaus; Döller, Birgit; Draschl, Petra; Rigal, Karl; Findl, Oliver

    2016-04-01

    The aim of this study was to examine the quality of intraoperative visualization of the posterior hyaloid, epiretinal membrane (ERM), inner limiting membrane (ILM), and hyporeflective subfoveal zone with a commercially available, microscope-integrated spectral-domain OCT setup (mi-SD-OCT) (Rescan 700; Carl Zeiss Meditec AG, Germany). Twenty patients prospectively scheduled for pars plana vitrectomy with membrane peeling due to an idiopathic ERM were included. Standard 23-gauge, three-port pars plana vitrectomy with membrane peeling and staining of the ERM with a trypan blue-based chromovitrectomy dye was performed in all cases. Intraoperative SD-OCT was performed before and after peeling and visualization of the posterior hyaloid, ERM, ILM, and presence of subfoveal hyporeflective zones were examined. OCT follow-ups were performed 2 days and 3 months after surgery. The study was approved by the local ethics committee of the city of Vienna. Successful intraoperative visualization of ERM by mi-SD-OCT was possible in all cases. The posterior hyaloid and ILM could not be seen in the mi-SD-OCT scans, whereas an intraoperative subfoveal hyporeflective zone presented in 35% of cases. In 12.5% an independent subfoveal hyporeflective zone presented postoperatively. Visual acuity improved in 93.8% of patients after surgery. mi-SD-OCT appears to be a valuable tool for intraoperative visualization of the ERM and offers immediate visualization of retinal anatomy during peeling. Therefore, it adds to the understanding of intraoperative traumatic changes due to the peeling procedure. Copyright 2016, SLACK Incorporated.

  18. Panel Discussion

    Science.gov (United States)

    Langer, James

    1997-03-01

    Panelists: Arthur Bienenstock, Stanford University Cherry Ann Murray, Lucent Technologies Venkatesh Narayanamurti, University of California-Santa Barbara Paul Peercy, SEMI-SEMATECH Robert Richardson, Cornell University James Roberto, Oak Ridge National Laboratory The Board on Physics and Astronomy is undertaking a series of reassessments of all branches of physics as the foundation of a new physics survey. As part of this project, a Committee on Condensed Matter and Materials Physics has been established under the leadership of Venkatesh Narayanamurti of the University of California-Santa Barbara. The committee has been working since June on a study that will include an illustrative recounting of major recent achievements; identification of new opportunities and challenges facing the field; and articulation-for leaders in government, industry, universities, and the public at large-of the important roles played by the field in modern society. An especially urgent issue is how to maintain the intellectual vitality of condensed matter and materials physics, and its contributions to the well-being of the United States, in an era of limited resources. The forum will feature a panel of materials researchers who are members of the Committee on Condensed Matter and Materials Physics. They will give a brief report on the status of the study and engage in a dialogue with the audience about issues facing the condensed matter and materials physics community. Broad community input is vital to the success of the study. Please come and make your voice heard!

  19. Hepatic (Liver) Function Panel

    Science.gov (United States)

    ... Educators Search English Español Blood Test: Hepatic (Liver) Function Panel KidsHealth / For Parents / Blood Test: Hepatic (Liver) ... kidneys ) is working. What Is a Hepatic (Liver) Function Panel? A liver function panel is a blood ...

  20. Comprehensive metabolic panel

    Science.gov (United States)

    Metabolic panel - comprehensive; Chem-20; SMA20; Sequential multi-channel analysis with computer-20; SMAC20; Metabolic panel 20 ... Chernecky CC, Berger BJ. Comprehensive metabolic panel (CMP) - blood. In: ... Tests and Diagnostic Procedures . 6th ed. St Louis, MO: ...

  1. Effect of incisional friction and ophthalmic viscosurgical devices on the heat generation of ultrasound during cataract surgery.

    Science.gov (United States)

    Floyd, Michael; Valentine, Jeremy; Coombs, Jamie; Olson, Randall J

    2006-07-01

    To determine the thermal features of the Legacy (Alcon) and Sovereign (Advanced Medical Optics) phacoemulsification machines in a cadaver eye and with 7 ophthalmic viscosurgical devices (OVDs). In situ and in vitro study. Temperature without occlusion was recorded at the sleeve placed in the wound of a cadaver eye, and temperature over baseline was determined after 60 seconds. The result was then compared with the results in a previous study that used balanced salt solution (BSS) in artificial chambers. In the second portion of the experiment, with irrigation and aspiration lines occluded, temperature was recorded at the sleeve placed in an artificial chamber filled with sodium hyaluronate 2.3% (Healon5), sodium hyaluronate 1.4% (Healon GV), sodium hyaluronate 1.0% (Healon), sodium hyaluronate 1.6% (Amvisc Plus), sodium hyaluronate 1.0% (Provisc), sodium hyaluronate 3.0%-chondroitin sulfate 4.0% (Viscoat), or hyaluronate 3.0% (Vitrax). Temperature over baseline was also determined after 60 seconds. These results were compared with each set of OVD data and with the results in the prior BSS study. In the eye-bank model, the Legacy machine had a 62% temperature increase from incisional friction and the Sovereign machine had a decrease of 8.6% over results in an artificial anterior chamber. The OVD temperature increases were greater for the Sovereign (Pgeneration in the Legacy, a stroke-length driven instrument, more than in the Sovereign, a power-driven instrument. Ophthalmic viscosurgical devices are not only a concern due to outflow occlusion but can also add up to 6 times the heat in comparison with BSS. The need to aspirate the OVD before using ultrasound is thus verified.

  2. Hip supporting device

    DEFF Research Database (Denmark)

    2011-01-01

    The present invention relates to a device for limiting movements in one or more anatomical joints, such as a device for limiting movement in the human hip joint after hip replacement surgery. This is provided by a device for limiting movement in the human hip joint, said device comprising: at least...

  3. Performance comparison between silicon solar panel and dye-sensitized solar panel in Malaysia

    Science.gov (United States)

    Hamed, N. K. A.; Ahmad, M. K.; Urus, N. S. T.; Mohamad, F.; Nafarizal, N.; Ahmad, N.; Soon, C. F.; Ameruddin, A. S.; Faridah, A. B.; Shimomura, M.; Murakami, K.

    2017-09-01

    In carrying out experimental research in performance between silicon solar panel and dye-sensitive solar panel, we have been developing a device and a system. This system has been developed consisting of controllers, hardware and software. This system is capable to get most of the input sources. If only need to change the main circuit and coding for a different source input value. This device is able to get the ambient temperature, surface temperature, surrounding humidity, voltage with load, current with load, voltage without load and current without load and save the data into external memory. This device is able to withstand the heat and rain as it was fabricated in a waterproof box. This experiment was conducted to examine the performance of both the solar panels which are capable to maintain their stability and performance. A conclusion based on data populated, the distribution of data for dye-sensitized solar panel is much better than silicon solar panel as dye-sensitized solar panel is very sensitive to heat and not depend only on midday where is that is the maximum ambient temperature for both solar panel as silicon solar panel only can give maximum and high output only when midday.

  4. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  5. Micro-inverter solar panel mounting

    Science.gov (United States)

    Morris, John; Gilchrist, Phillip Charles

    2016-02-02

    Processes, systems, devices, and articles of manufacture are provided. Each may include adapting micro-inverters initially configured for frame-mounting to mounting on a frameless solar panel. This securement may include using an adaptive clamp or several adaptive clamps secured to a micro-inverter or its components, and using compressive forces applied directly to the solar panel to secure the adaptive clamp and the components to the solar panel. The clamps can also include compressive spacers and safeties for managing the compressive forces exerted on the solar panels. Friction zones may also be used for managing slipping between the clamp and the solar panel during or after installation. Adjustments to the clamps may be carried out through various means and by changing the physical size of the clamps themselves.

  6. Magnetic evaluation of a solar panel using HTS-SQUID

    Energy Technology Data Exchange (ETDEWEB)

    Kiwa, Toshihiko, E-mail: kiwa@okayama-u.ac.jp; Fukudome, Yohei; Miyazaki, Shingo; Saari, Mohd Mawardi; Sakai, Kenji; Tsukada, Keiji

    2013-11-15

    Highlights: •The magnetic evaluation system of a solar panel using HTS-SQUID has been developed. •The electric circuits made by the discrete devices on the circuit board were visualized. •The electric properties of the commercial solar panels were demonstrated. -- Abstract: The magnetic evaluation system of a solar panel using HTS-SQUID has been proposed and developed. A normal pick-up coil was applied to detect the tangential magnetic field to the panel surface. Since the detected field could be related to the currents of the solar panels, the electric properties of the solar panels could be evaluated. In this work, the evaluation of the electric properties of the commercial solar panels as well as the electric circuits made by the discrete devices on the circuit board was visualized.

  7. Magnetic evaluation of a solar panel using HTS-SQUID

    International Nuclear Information System (INIS)

    Kiwa, Toshihiko; Fukudome, Yohei; Miyazaki, Shingo; Saari, Mohd Mawardi; Sakai, Kenji; Tsukada, Keiji

    2013-01-01

    Highlights: •The magnetic evaluation system of a solar panel using HTS-SQUID has been developed. •The electric circuits made by the discrete devices on the circuit board were visualized. •The electric properties of the commercial solar panels were demonstrated. -- Abstract: The magnetic evaluation system of a solar panel using HTS-SQUID has been proposed and developed. A normal pick-up coil was applied to detect the tangential magnetic field to the panel surface. Since the detected field could be related to the currents of the solar panels, the electric properties of the solar panels could be evaluated. In this work, the evaluation of the electric properties of the commercial solar panels as well as the electric circuits made by the discrete devices on the circuit board was visualized

  8. Localized environment characterization device

    KAUST Repository

    Alzain, Hashim

    2016-07-21

    Various apparatuses and methods are provided for measuring the likely environmental impact of a particular geographic location on power generation properties of potential solar installations at the particular location. In an example embodiment of one such apparatus, a measurement device is provided. The measurement device includes a base portion comprising a base frame element disposed on a plurality of supporting legs, and a top panel comprising a series of connected members and one or more measurement modules whose planar dimensions are defined by the series of connected members. The top panel is connected to the base portion by a joint such that the top panel can rotate about the joint, and a panel support element is configured to fasten the top panel immovably at a desired degree of rotation in relation to the base portion.

  9. 76 FR 69034 - Microbiology Devices; Classification of In Vitro Diagnostic Device for Yersinia Species Detection

    Science.gov (United States)

    2011-11-07

    ... Drug Administration 21 CFR Part 866 Microbiology Devices; Classification of In Vitro Diagnostic Device... CFR Part 866 [Docket No. FDA-2011-N-0729] Microbiology Devices; Classification of In Vitro Diagnostic... of the Microbiology Devices Advisory Panel (the panel). FDA is publishing in this document the...

  10. Hepatitis virus panel

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003558.htm Hepatitis virus panel To use the sharing features on this page, please enable JavaScript. The hepatitis virus panel is a series of blood tests used ...

  11. Antinuclear antibody panel

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003535.htm Antinuclear antibody panel To use the sharing features on this page, please enable JavaScript. The antinuclear antibody panel is a blood test that looks at ...

  12. Paneling architectural freeform surfaces

    KAUST Repository

    Eigensatz, Michael; Kilian, Martin; Schiftner, Alexander; Mitra, Niloy J.; Pottmann, Helmut; Pauly, Mark

    2010-01-01

    with a selected technology at reasonable cost, while meeting the design intent and achieving the desired aesthetic quality of panel layout and surface smoothness. The production of curved panels is mostly based on molds. Since the cost of mold fabrication

  13. Paneling architectural freeform surfaces

    KAUST Repository

    Eigensatz, Michael

    2010-07-26

    The emergence of large-scale freeform shapes in architecture poses big challenges to the fabrication of such structures. A key problem is the approximation of the design surface by a union of patches, socalled panels, that can be manufactured with a selected technology at reasonable cost, while meeting the design intent and achieving the desired aesthetic quality of panel layout and surface smoothness. The production of curved panels is mostly based on molds. Since the cost of mold fabrication often dominates the panel cost, there is strong incentive to use the same mold for multiple panels. We cast the major practical requirements for architectural surface paneling, including mold reuse, into a global optimization framework that interleaves discrete and continuous optimization steps to minimize production cost while meeting user-specified quality constraints. The search space for optimization is mainly generated through controlled deviation from the design surface and tolerances on positional and normal continuity between neighboring panels. A novel 6-dimensional metric space allows us to quickly compute approximate inter-panel distances, which dramatically improves the performance of the optimization and enables the handling of complex arrangements with thousands of panels. The practical relevance of our system is demonstrated by paneling solutions for real, cutting-edge architectural freeform design projects. © 2010 ACM.

  14. Paneling architectural freeform surfaces

    KAUST Repository

    Eigensatz, Michael

    2010-07-25

    The emergence of large-scale freeform shapes in architecture poses big challenges to the fabrication of such structures. A key problem is the approximation of the design surface by a union of patches, so-called panels, that can be manufactured with a selected technology at reasonable cost, while meeting the design intent and achieving the desired aesthetic quality of panel layout and surface smoothness. The production of curved panels is mostly based on molds. Since the cost of mold fabrication often dominates the panel cost, there is strong incentive to use the same mold for multiple panels. We cast the major practical requirements for architectural surface paneling, including mold reuse, into a global optimization framework that interleaves discrete and continuous optimization steps to minimize production cost while meeting user-specified quality constraints. The search space for optimization is mainly generated through controlled deviation from the design surface and tolerances on positional and normal continuity between neighboring panels. A novel 6-dimensional metric space allows us to quickly compute approximate inter-panel distances, which dramatically improves the performance of the optimization and enables the handling of complex arrangements with thousands of panels. The practical relevance of our system is demonstrated by paneling solutions for real, cutting-edge architectural freeform design projects.

  15. Semiconductor-based, large-area, flexible, electronic devices

    Science.gov (United States)

    Goyal, Amit [Knoxville, TN

    2011-03-15

    Novel articles and methods to fabricate the same resulting in flexible, large-area, triaxially textured, single-crystal or single-crystal-like, semiconductor-based, electronic devices are disclosed. Potential applications of resulting articles are in areas of photovoltaic devices, flat-panel displays, thermophotovoltaic devices, ferroelectric devices, light emitting diode devices, computer hard disc drive devices, magnetoresistance based devices, photoluminescence based devices, non-volatile memory devices, dielectric devices, thermoelectric devices and quantum dot laser devices.

  16. REINFORCED COMPOSITE PANEL

    DEFF Research Database (Denmark)

    2003-01-01

    A composite panel having front and back faces, the panel comprising facing reinforcement, backing reinforcement and matrix material binding to the facing and backing reinforcements, the facing and backing reinforcements each independently comprising one or more reinforcing sheets, the facing rein...... by matrix material, the facing and backing reinforcements being interconnected to resist out-of-plane relative movement. The reinforced composite panel is useful as a barrier element for shielding structures, equipment and personnel from blast and/or ballistic impact damage....

  17. Solar reflection panels

    Science.gov (United States)

    Diver, Jr., Richard B.; Grossman, James W [Albuquerque, NM; Reshetnik, Michael [Boulder, CO

    2006-07-18

    A solar collector comprising a glass mirror, and a composite panel, wherein the back of the mirror is affixed to a front surface of the composite panel. The composite panel comprises a front sheet affixed to a surface of a core material, preferably a core material comprising a honeycomb structure, and a back sheet affixed to an opposite surface of the core material. The invention may further comprise a sealing strip, preferably comprising EPDM, positioned between the glass mirror and the front surface of the composite panel. The invention also is of methods of making such solar collectors.

  18. 77 FR 16126 - Microbiology Devices; Reclassification of Nucleic Acid-Based Systems for Mycobacterium tuberculosis

    Science.gov (United States)

    2012-03-19

    .... FDA-2012-N-0159] Microbiology Devices; Reclassification of Nucleic Acid-Based Systems for... convened a meeting of the Microbiology Devices Panel of the Medical Devices Advisory Committee (Microbiology Devices Panel) on June 29, 2011 (Ref. 2). Although not a formal reclassification meeting, panel...

  19. Innovations in Bariatric Surgery.

    Science.gov (United States)

    Zhu, Catherine; Pryor, Aurora D

    2015-11-01

    Surgery has consistently been demonstrated to be the most effective long-term therapy for the treatment of obesity. However, despite excellent outcomes with current procedures, most patients with obesity- and weight-related comorbidities who meet criteria for surgical treatment choose not to pursue surgery out of fear of operative risks and complications or concerns about high costs. Novel minimally invasive procedures and devices may offer alternative solutions for patients who are hesitant to pursue standard surgical approaches. These procedures may be used for primary treatment of obesity, early intervention for patients approaching morbid obesity, temporary management prior to bariatric surgery, or revision of bypass surgery associated with weight regain. Novel bariatric procedures can in general be divided into four categories: endoluminal space-occupying devices, gastric suturing and restrictive devices, absorption-limiting devices, and neural-hormonal modulating devices. Many of these are only approved as short-term interventions, but these devices may be effective for patients desiring low-risk procedures or a transient effect. We will see the expansion of indications and alternatives for metabolic surgery as these techniques gain approval.

  20. Stressed skin panels

    Energy Technology Data Exchange (ETDEWEB)

    Anon

    2001-07-01

    Advantages and disadvantages of stressed skin panels, also known as structural insulated panels (SIPs), are discussed as material and labour-saving alternatives to traditional stick framing. Stressed skin panels are manufactured 'sandwich' assemblies with a rigid insulating polystyrene foam core, whose interior and exterior surfaces are bonded into panels. The skins distribute and carry the structural loading while the bonded foam core provides insulation and keeps the two skins aligned. Since there are fewer framing members, there is little thermal bridging and the R-value remains high. SIPs are usually manufactured in four feet by eight feet panels, although some manufacturers can produce panels up to eight feet by forty feet. SIPs are resource efficient as they use less wood than conventional framing (about 25 per cent less); can structurally cover large spans, requiring less supplementary framing. Use of SIPs eliminate the need for headers over small openings; provide the ability to nail anywhere; create less scrap and waste; lessen vulnerability to unfavourable weather and other job-site hazards, can reduce delays, and often can produce significant savings in material and labour costs. Limitations include the more complex approaches to plumbing and electrical systems, although this can be minimized by designers by incorporating much of the plumbing and electrical work on interior (non-panel) walls. Most stressed skin panels require one-half inch interior gypsum drywall. If become wet, stressed skin panels take a long time to dry out and may harbour mold growth. Larger stressed-skin panels used in floors and roofs, may require cranes or other machinery for handling because of their weight. Although not without some environmental impact, overall, stressed skin panels are judged to be a resource-efficient building technology with significant energy-efficiency benefits and distinct advantages over stick framing. 3 photos.

  1. Thermonuclear device

    International Nuclear Information System (INIS)

    Tezuka, Masaru.

    1993-01-01

    Protrusions and recesses are formed to a vacuum vessel and toroidal magnetic coils, and they are engaged. Since the vacuum vessel is generally supported firmly by a rack or the like by support legs, the toroidal magnetic field coils can be certainly supported against tumbling force. Then, there can be attained strong supports for the toroidal magnetic field coils, in addition to support by wedges on the side of inboard and support by share panels on the side of outboard, capable of withstanding great electromagnetic forces which may occur in large-scaled next-generation devices. That is, toroidal magnetic field coils excellent from a view point of deformation and stress can be obtained, to provide a thermonuclear device of higher reliability. (N.H.)

  2. Panel 5: Microbiology and Immunology Panel

    Science.gov (United States)

    Murphy, Timothy F.; Chonmaitree, Tasnee; Barenkamp, Stephen; Kyd, Jennelle; Nokso-Koivisto, Johanna; Patel, Janak A.; Heikkinen, Terho; Yamanaka, Noboru; Ogra, Pearay; Swords, W. Edward; Sih, Tania; Pettigrew, Melinda M.

    2014-01-01

    Objective The objective is to perform a comprehensive review of the literature from January 2007 through June 2011 on the virology, bacteriology, and immunology related to otitis media. Data Sources PubMed database of the National Library of Medicine. Review Methods Three subpanels with co-chairs comprising experts in the virology, bacteriology, and immunology of otitis media were formed. Each of the panels reviewed the literature in their respective fields and wrote draft reviews. The reviews were shared with all panel members, and a second draft was created. The entire panel met at the 10th International Symposium on Recent Advances in Otitis Media in June 2011 and discussed the review and refined the content further. A final draft was created, circulated, and approved by the panel. Conclusion Excellent progress has been made in the past 4 years in advancing an understanding of the microbiology and immunology of otitis media. Advances include laboratory-based basic studies, cell-based assays, work in animal models, and clinical studies. Implications for Practice The advances of the past 4 years formed the basis of a series of short-term and long-term research goals in an effort to guide the field. Accomplishing these goals will provide opportunities for the development of novel interventions, including new ways to better treat and prevent otitis media. PMID:23536533

  3. RECIPANEL: RECYCLED PAPER PANELS

    Directory of Open Access Journals (Sweden)

    HERNÁN CAÑOLA

    2012-01-01

    Full Text Available En este artículo se estudia la fabricación y el comportamiento mecánico de paneles a base de papel reciclado. El objetivo principal del proyecto es producir un prototipo de panel que emplee elementos provenientes de residuos sólidos (papel periódico y de un material conglomerante (cemento Portland blanco. El panel debe ser económico, debe tener buenas propiedades mecánicas y debe tener dimensiones comerciales para su uso en muros tabiques y en cielos falsos en la industria de la construcción. El Recipanel es un panel no estructural a base de papel reciclado. El Recipanel cumple las normas colombianas en lo relativo a los paneles de uso no estructural y presenta además unas excelentes características mecánicas.

  4. Puncture panel optimization

    International Nuclear Information System (INIS)

    Glass, R.E.; Longenbaugh, R.S.

    1986-01-01

    Sandia National Laboratories developed the TRansUranic PACkage Transporter (TRUPACT) to transport defense contact-handled transuranic wastes. The package has been designed to meet the normal and hypothetical accident conditions in 10CFR71 which includes the demonstrated ability to survive a 1-meter drop onto a mild steel pin. The puncture protection is provided by puncture resistant panels. In conjunction with the development of TRUPACT, a series of experiments has been conducted to reduce the weight of the puncture resistant panels. The initial scoping tests resulted in a preliminary design incorporating 30 layers of Kevlar. This design has been shown to meet the regulatory puncture test. To reduce the weight of this panel, subscale tests were conducted on panels utilizing Kevlar yarns with varying mass per unit length (denier) as well as different resins. This paper reviews the testing undertaken in the original panel development and discusses the results obtained from the recent subscale and full-scale optimization tests

  5. Solar panel cleaning robot

    Science.gov (United States)

    Nalladhimmu, Pavan Kumar Reddy; Priyadarshini, S.

    2018-04-01

    As the demand of electricity is increasing, there is need to using the renewable sources to produce the energy at present of power shortage, the use of solar energy could be beneficial to great extent and easy to get the maximum efficiency. There is an urgent in improving the efficiency of solar power generation. Current solar panels setups take a major power loss when unwanted obstructions cover the surface of the panels. To make solar energy more efficiency of solar array systems must be maximized efficiency evaluation of PV panels, that has been discussed with particular attention to the presence of dust on the efficiency of the PV panels have been highlighted. This paper gives the how the solar panel cleaning system works and designing of the cleaning system.

  6. A newly developed oval-shaped port device (E•Z ACCESS Oval type) for use in reduced port surgery: initial clinical experiences with cholecystectomy.

    Science.gov (United States)

    Shibao, Kazunori; Takagi, Tsuyoshi; Higure, Aiichiro; Yamaguchi, Koji

    2013-09-01

    We recently developed an oval-shaped E•Z Access device designed exclusively for use with the LAP PROTECTOR™ Oval type device (Hakko Co. Ltd., Tokyo, Japan). The transverse abdominal opening diameter made by round-shaped (Alexis® Wound Retractor, Applied Medical, Rancho Santa Margarita, CA; and LAP PROTECTOR™ Round type) and oval-shaped (LAP PROTECTOR™ Oval type) wound retractors was measured and compared in 5 patients with cholecystolithiasis. Each device was placed through a single 25-mm longitudinal umbilical incision, and the length of trocar separation was compared. LESS cholecystectomy was then performed using the oval-shaped E•Z ACCESS/LAP PROTECTOR™. The transverse abdominal opening diameter was maximized with the LAP PROTECTOR™ Oval type device. The average distance between the working-ports for the glove method, round-shaped, and oval-shaped E•Z ACCESS/LAP PROTECTOR™ devices in the 25-mm umbilical incisions were 20 ± 0.8 mm, 24 ± 1.5 mm, and 35 ± 0.8 mm, respectively. Wider trocar separation was achieved using the oval-shaped device, making the surgical procedures easier to perform. No perioperative port-related or surgical complications were observed. LESS cholecystectomy using the E•Z ACCESS Oval type device was found to be technically feasible. The Oval type device appears to allow for wider trocar separation, thereby reducing stress on the surgeon, ensuring patient safety, and providing cosmetic benefits.

  7. Does Low-Field Intraoperative Magnetic Resonance Improve the Results of Endoscopic Pituitary Surgery? Experience of the Implementation of a New Device in a Referral Center.

    Science.gov (United States)

    García, Sergio; Reyes, Luis; Roldán, Pedro; Torales, Jorge; Halperin, Irene; Hanzu, Felicia; Langdon, Cristobal; Alobid, Isam; Enseñat, Joaquim

    2017-06-01

    To assess the contribution of low-field intraoperative magnetic resonance (iMRI) to endoscopic pituitary surgery. We analyzed a prospective series of patients undergoing endoscopic endonasal surgery for pituitary macroadenomas assisted with a low-field iMRI (PoleStarN30, 0.15 T [Medtronic]). Clinical, radiologic, and surgical variables were analyzed and compared with our fully endoscopic historic cohort operated on without iMRI assistance. A bibliographic review of pituitary surgery assisted with iMRI was conducted. Thirty patients (57% female; mean age, 55 years) were prospectively analyzed. The most frequent tumor subtype was nonfunctioning macroadenoma (50%). The average Knosp grade was 2.3 and mean tumor size was 18 mm. Surgical and positioning time were 102 and 47 minutes, respectively. Hospital stay and complication rates were similar to our historical cohort for pituitary surgery. Mean follow-up was 10 months. Complete resection (CR) was achieved in 83% of patients. Seven patients (23%) benefited from iMRI assistance and achieved a CR in their surgeries. All patients except 1 experienced hormonal activity remission. iMRI sensitivity and specificity was 0.8 and 1, respectively. Although not statistically significant, CR rates were globally 11.5% superior in iMRI series compared with our historical cohort. This difference was independent of cavernous sinus invasiveness grade (CR rate increased 12.5% for Knosp grade 0-2 and 8.1% for Knosp grade 3-4). Low-field iMRI is a useful and safe assistance even in advanced surgical techniques such as endoscopy. Its contribution is limited by the intrinsic features of the tumor. Further randomized studies are required to confirm the cost-effectiveness of iMRI in pituitary surgery. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. 78 FR 4094 - Effective Date of Requirement for Premarket Approval for Two Class III Preamendments Devices

    Science.gov (United States)

    2013-01-18

    ... devices. On August 8, 2001, the Orthopaedic and Rehabilitation Devices Panel (the Panel) recommended five... function due to excessive wear, fracture, deformation of the device components, or loosening of the device... excessive wear, fracture, deformation of the device components, or loosening of the device in the surgical...

  9. Fiscal 2000 achievement report on the venture business assisting type regional consortium - Minor business creation base type. Development of touch panel display operated by micro-Peltier device; 2000 nendo chiiki consortium kenkyu kaihatsu jigyo seika hokokusho. Micro Peltier soshi ni yoru shokkaku display no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    The project aims to develop a small, light, and inexpensive touch panel display that enables visually handicapped people to transmit information by use of their manual sensation. Information from computers or the like is exhibited on the display in arrays of hillocks and dents. For improvement on display resolution and for cost reduction, efforts are made (1) to employ micro-Peltier devices for the simplification of the hillock-dent display mechanism and for the realization of a high resolution tactile display and (2) to establish a technology for manufacturing low-cost micro-Peltier devices. In the tactile display to be developed, the hillocks and dents are formed using gas-filled tiny balloons. The balloons are 2-dimensionally arranged, with the gas therein to be expanded and contracted via micro-Peltier devices. Difference between hillock-dent arrays and changes therein with the passage of time provide information. The gas in the balloons is inflated and contracted through the operation of micro-Peltier devices. In concrete terms, efforts were made to develop (1) a prototype hillock-dent display, (2) a technology for manufacturing high-performance low-cost micro-Peltier devices, and (3) a software program for computers to drive tactile displays. (NEDO)

  10. Make Your Own Solar Panel.

    Science.gov (United States)

    Suzuki, David

    1992-01-01

    Presents an activity in which students make a simulated solar panel to learn about the principles behind energy production using solar panels. Provides information about how solar panels function to produce energy. (MCO)

  11. Interfacial Crack Arrest in Sandwich Panels with Embedded Crack Stoppers Subjected to Fatigue Loading

    DEFF Research Database (Denmark)

    Martakos, G.; Andreasen, J. H.; Berggreen, Christian

    2017-01-01

    A novel crack arresting device has been implemented in sandwich panels and tested using a special rig to apply out-of-plane loading on the sandwich panel face-sheets. Fatigue crack propagation was induced in the face-core interface of the sandwich panels which met the crack arrester. The effect o...

  12. Blue Ribbon Panel Report

    Science.gov (United States)

    An NCI Cancer Currents blog by the NCI acting director thanking the cancer community for contributing to the Cancer Moonshot Blue Ribbon Panel report, which was presented to the National Cancer Advisory Board on September 7.

  13. Panel acoustic contribution analysis.

    Science.gov (United States)

    Wu, Sean F; Natarajan, Logesh Kumar

    2013-02-01

    Formulations are derived to analyze the relative panel acoustic contributions of a vibrating structure. The essence of this analysis is to correlate the acoustic power flow from each panel to the radiated acoustic pressure at any field point. The acoustic power is obtained by integrating the normal component of the surface acoustic intensity, which is the product of the surface acoustic pressure and normal surface velocity reconstructed by using the Helmholtz equation least squares based nearfield acoustical holography, over each panel. The significance of this methodology is that it enables one to analyze and rank relative acoustic contributions of individual panels of a complex vibrating structure to acoustic radiation anywhere in the field based on a single set of the acoustic pressures measured in the near field. Moreover, this approach is valid for both interior and exterior regions. Examples of using this method to analyze and rank the relative acoustic contributions of a scaled vehicle cabin are demonstrated.

  14. Autoimmune liver disease panel

    Science.gov (United States)

    Liver disease test panel - autoimmune ... Autoimmune disorders are a possible cause of liver disease. The most common of these diseases are autoimmune hepatitis and primary biliary cholangitis (formerly called primary biliary cirrhosis). This group of tests ...

  15. Hexagon solar power panel

    Science.gov (United States)

    Rubin, I. (Inventor)

    1978-01-01

    A solar energy panel support is described upon which silicon cells are arrayed. The cells are wafer thin and of two geometrical types, both of the same area and electrical rating, namely hexagon cells and hourglass cells. The hourglass cells are composites of half hexagons. A near perfect nesting relationship of the cells achieves a high density packing whereby optimum energy production per panel area is achieved.

  16. Propulsion Systems Panel deliberations

    Science.gov (United States)

    Bianca, Carmelo J.; Miner, Robert; Johnston, Lawrence M.; Bruce, R.; Dennies, Daniel P.; Dickenson, W.; Dreshfield, Robert; Karakulko, Walt; Mcgaw, Mike; Munafo, Paul M.

    1993-01-01

    The Propulsion Systems Panel was established because of the specialized nature of many of the materials and structures technology issues related to propulsion systems. This panel was co-chaired by Carmelo Bianca, MSFC, and Bob Miner, LeRC. Because of the diverse range of missions anticipated for the Space Transportation program, three distinct propulsion system types were identified in the workshop planning process: liquid propulsion systems, solid propulsion systems and nuclear electric/nuclear thermal propulsion systems.

  17. Honeycomb metal panel

    International Nuclear Information System (INIS)

    1979-01-01

    Product constituted by a honeycomb metal panel that can be employed to advantage for manufacturing lagging by sandwiching it between two plane sheets, utilized in particular in the nuclear industry where lagging has to have a very long life strength. The honeycomb metal panel is made of an expanded metal extrusion previously cut so as to form, after additional drawing, a honeycomb structure with square or rectangular cells with a plane surface [fr

  18. Endoscopic Devices for Obesity.

    Science.gov (United States)

    Sampath, Kartik; Dinani, Amreen M; Rothstein, Richard I

    2016-06-01

    The obesity epidemic, recognized by the World Health Organization in 1997, refers to the rising incidence of obesity worldwide. Lifestyle modification and pharmacotherapy are often ineffective long-term solutions; bariatric surgery remains the gold standard for long-term obesity weight loss. Despite the reported benefits, it has been estimated that only 1% of obese patients will undergo surgery. Endoscopic treatment for obesity represents a potential cost-effective, accessible, minimally invasive procedure that can function as a bridge or alternative intervention to bariatric surgery. We review the current endoscopic bariatric devices including space occupying devices, endoscopic gastroplasty, aspiration technology, post-bariatric surgery endoscopic revision, and obesity-related NOTES procedures. Given the diverse devices already FDA approved and in development, we discuss the future directions of endoscopic therapies for obesity.

  19. Turbinate surgery

    Science.gov (United States)

    Turbinectomy; Turbinoplasty; Turbinate reduction; Nasal airway surgery; Nasal obstruction - turbinate surgery ... There are several types of turbinate surgery: Turbinectomy: All or ... This can be done in several different ways, but sometimes a ...

  20. Bariatric Surgery

    Science.gov (United States)

    ... often. Each type of surgery has advantages and disadvantages. Bariatric Surgery Benefits Bariatric surgery can improve many ... Grants & Grant History Research Resources Research at NIDDK Technology Advancement & Transfer Meetings & Workshops Health Information Diabetes Digestive ...

  1. Lung surgery

    Science.gov (United States)

    ... are thoracotomy and video-assisted thoracoscopic surgery (VATS). Robotic surgery may also be used. Lung surgery using ... Center-Shreveport, Shreveport, LA. Review provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, ...

  2. Plastic Surgery

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Plastic Surgery KidsHealth / For Teens / Plastic Surgery What's in ... her forehead lightened with a laser? What Is Plastic Surgery? Just because the name includes the word " ...

  3. State of the art of medical devices featuring smart electro-rheological and magneto-rheological fluids

    Directory of Open Access Journals (Sweden)

    Jong-Seok Oh

    2017-10-01

    Full Text Available Recently, smart fluids have drawn significant attention and growing a great interest in a broad range of engineering applications such as automotive and medical areas. In this article, two smart fluids called electro-rheological (ER fluid and magneto-rheological (MR fluid are reviewed in terms of medical applications. Especially, this article describes the attributes and inherent properties of individual medical and rehabilitation devices. The devices surveyed in this article include multi-degree-of-freedom haptic masters for robot surgery, thin membrane touch panels for braille readers, sponge-like tactile sensors to feel human tissues such as liver, rehabilitation systems such as prosthetic leg, and haptic interfaces for dental implant surgery. The operating principle, inherent characteristics and practical feasibility of each medical device or system are fully discussed in details.

  4. Rational Design of Composite Panels

    DEFF Research Database (Denmark)

    Riber, Hans Jørgen

    1996-01-01

    A non-linear structural model for composite panels is presented. The non-linear terms in the lateral displacements are modelled as an additional set of lateral loads acting on the panel. Hence the solution is reduced to that of an equivalent panel with small displacements In order to treat sandwich...... Norske Veritas', DNV, building rules concerning high-speed light craft, in which the panel scantlings are often restricted by a maximum lateral deflection connected with the panel span....

  5. Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Won Seok; Park, Kwang Woo; Shin, Dong Bong; Kim, Jong Dae; Kim, Sei Joon; Ha, Jin Sook; Jeon, Mi Jin; Cho, Yoojin; Jung, Inho [Dept. of Radiation Oncology, Gangnam Severance Hospital, Seoul, (Korea, Republic of)

    2016-06-15

    This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0

  6. Comparison and evaluation between 3D-bolus and step-bolus, the assistive radiotherapy devices for the patients who had undergone modified radical mastectomy surgery

    International Nuclear Information System (INIS)

    Jang, Won Seok; Park, Kwang Woo; Shin, Dong Bong; Kim, Jong Dae; Kim, Sei Joon; Ha, Jin Sook; Jeon, Mi Jin; Cho, Yoojin; Jung, Inho

    2016-01-01

    This study aimed to compare and evaluate between the efficiency of two respective devices, 3D-bolus and step-bolus when the devices were used for the treatment of patients whose chest walls were required to undergo the electron beam therapy after the surgical procedure of modified radical mastectomy, MRM. The treatment plan of reverse hockey stick method, using the photon beam and electron beam, had been set for six breast cancer patients and these 6 breast cancer patients were selected to be the subjects for this study. The prescribed dose of electron beam for anterior chest wall was set to be 180 cGy per treatment and both the 3D-bolus, produced using 3D printer(CubeX, 3D systems, USA) and the self-made conventional step-bolus were used respectively. The surface dose under 3D-bolus and step-bolus was measured at 5 measurement spots of iso-center, lateral, medial, superior and inferior point, using GAFCHROMIC EBT3 film (International specialty products, USA) and the measured value of dose at 5 spots was compared and analyzed. Also the respective treatment plan was devised, considering the adoption of 3D-bolus and stepbolus and the separate treatment results were compared to each other. The average surface dose was 179.17 cGy when the device of 3D-bolus was adopted and 172.02 cGy when step-bolus was adopted. The average error rate against the prescribed dose of 180 cGy was -(minus) 0.47% when the device of 3D-bolus was adopted and it was -(minus) 4.43% when step-bolus was adopted. It was turned out that the maximum error rate at the point of iso-center was 2.69%, in case of 3D-bolus adoption and it was 5,54% in case of step-bolus adoption. The maximum discrepancy in terms of treatment accuracy was revealed to be about 6% when step-bolus was adopted and to be about 3% when 3D-bolus was adopted. The difference in average target dose on chest wall between 3D-bolus treatment plan and step-bolus treatment plan was shown to be insignificant as the difference was only 0

  7. The future of glaucoma surgery

    Directory of Open Access Journals (Sweden)

    Arsham Sheybani

    2015-01-01

    Full Text Available Glaucoma surgery is ripe for innovation. In the last few years, there has been a substantial increase in the number of devices approaching commercialization. While not all that is new is necessarily good, the role of these devices in changing glaucoma surgery is equally important in terms of both success and failure. Trabeculectomy, the most commonly performed incisional filtration surgery for glaucoma, is subjective by nature and certainly has risks. As devices aim to standardize glaucoma surgery, specifically subconjunctival filtration surgery, predictability and in turn safety should theoretically improve. This may allow the glaucoma surgeon to intervene earlier in the disease process, prevent more advanced vision loss and potentially decrease the burden of medications.

  8. Panels of microporous insulation

    Energy Technology Data Exchange (ETDEWEB)

    McWilliams, J.A.; Morgan, D.E.; Jackson, J.D.J.

    1990-08-07

    Microporous thermal insulation materials have a lattice structure in which the average interstitial dimension is less than the mean free path of the molecules of air or other gas in which the material is arranged. This results in a heat flow which is less than that attributable to the molecular heat diffusion of the gas. According to this invention, a method is provided for manufacturing panels of microporous thermal insulation, in particular such panels in which the insulation material is bonded to a substrate. The method comprises the steps of applying a film of polyvinyl acetate emulsion to a non-porous substrate, and compacting powdery microporous thermal insulation material against the film so as to cause the consolidated insulation material to bond to the substrate and form a panel. The polyvinyl acetate may be applied by brushing or spraying, and is preferably allowed to dry prior to compacting the insulation material. 1 fig.

  9. Advanced solar panel designs

    Science.gov (United States)

    Ralph, E. L.; Linder, E.

    1995-01-01

    This paper describes solar cell panel designs that utilize new hgih efficiency solar cells along with lightweight rigid panel technology. The resulting designs push the W/kg and W/sq m parameters to new high levels. These new designs are well suited to meet the demand for higher performance small satellites. This paper reports on progress made on two SBIR Phase 1 contracts. One panel design involved the use of large area (5.5 cm x 6.5 cm) GaAs/Ge solar cells of 19% efficiency combined with a lightweight rigid graphite fiber epoxy isogrid substrate configuration. A coupon (38 cm x 38 cm) was fabricated and tested which demonstrated an array specific power level of 60 W/kg with a potential of reaching 80 W/kg. The second panel design involved the use of newly developed high efficiency (22%) dual junction GaInP2/GaAs/Ge solar cells combined with an advanced lightweight rigid substrate using aluminum honeycomb core with high strength graphite fiber mesh facesheets. A coupon (38 cm x 38 cm) was fabricated and tested which demonstrated an array specific power of 105 W/kg and 230 W/sq m. This paper will address the construction details of the panels and an a analysis of the component weights. A strawman array design suitable for a typical small-sat mission is described for each of the two panel design technologies being studied. Benefits in respect to weight reduction, area reduction, and system cost reduction are analyzed and compared to conventional arrays.

  10. Panel 3 - characterization

    Energy Technology Data Exchange (ETDEWEB)

    Erck, R.A.; Erdemir, A.; Janghsing Hsieh; Lee, R.H.; Xian Zheng Pan; Deming Shu [Argonne National Lab., IL (United States); Feldman, A. [National Inst. of Standards and Technology, Gaithersburg, MD (United States); Glass, J.T. [North Carolina State Univ., Raleigh (United States); Kleimer, R. [Coors Ceramics Co., Golden, CO (United States); Lawton, E.A. [JPL/Caltech, Pasadena, CA (United States); McHargue, C.J. [Univ. of Tennessee, Knoxville (United States)

    1993-01-01

    The task of this panel was to identify and prioritize needs in the area of characterization of diamond and diamond-like-carbon (DLC) films for use in the transportation industry. Until recent advances in production of inexpensive films of diamonds and DLC, it was not feasible that these materials could be mass produced. The Characterization Panel is restricting itself to identifying needs in areas that would be most useful to manufacturers and users in producing and utilizing diamond and DLC coatings in industry. These characterization needs include in-situ monitoring during growth, relation of structure to performance, and standards and definitions.

  11. Analysis of Panel Data

    Science.gov (United States)

    Hsiao, Cheng

    2003-02-01

    Panel data models have become increasingly popular among applied researchers due to their heightened capacity for capturing the complexity of human behavior, as compared to cross-sectional or time series data models. This second edition represents a substantial revision of the highly successful first edition (1986). Recent advances in panel data research are presented in an accessible manner and are carefully integrated with the older material. The thorough discussion of theory and the judicious use of empirical examples make this book useful to graduate students and advanced researchers in economics, business, sociology and political science.

  12. Advanced Solar Panel Designs

    Science.gov (United States)

    Ralph, E. L.; Linder, E. B.

    1995-01-01

    Solar panel designs that utilize new high-efficiency solar cells and lightweight rigid panel technologies are described. The resulting designs increase the specific power (W/kg) achievable in the near-term and are well suited to meet the demands of higher performance small satellites (smallsats). Advanced solar panel designs have been developed and demonstrated on two NASA SBIR contracts at Applied Solar. The first used 19% efficient, large area (5.5 cm x 6.5 cm) GaAs/Ge solar cells with a lightweight rigid graphite epoxy isogrid substrate configuration. A 1,445 sq cm coupon was fabricated and tested to demonstrate 60 W/kg with a high potential of achieving 80 W/kg. The second panel design used new 22% efficiency, dual-junction GaInP2/GaAs/Ge solar cells combined with a lightweight aluminum core/graphite fiber mesh facesheet substrate. A 1,445 sq cm coupon was fabricated and tested to demonstrate 105 W/kg with the potential of achieving 115 W/kg.

  13. INTERNATIONAL COLLABORATION: Panelling

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    At the meeting of the International Committee for Future Accelerators (ICFA), in Geneva in July, Chairman A.N. Skrinsky of Novosibirsk reviewed ICFA progress, particularly the activities of the specialist Panels which pursue specific Committee objectives in guiding worldwide collaboration in high energy physics

  14. INTERNATIONAL COLLABORATION: Panelling

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1991-10-15

    At the meeting of the International Committee for Future Accelerators (ICFA), in Geneva in July, Chairman A.N. Skrinsky of Novosibirsk reviewed ICFA progress, particularly the activities of the specialist Panels which pursue specific Committee objectives in guiding worldwide collaboration in high energy physics.

  15. Law Panel in action.

    Science.gov (United States)

    Odulana, J

    In September 1976 the Africa Regional Council (ARC) of IPPF created a Law Panel to 1) advise the ARC on the emphasis of laws and parenthood programs in the region, 2) investigate legal obstacles to family planning and ways of removing them, 3) institute a monitoring service on laws and court decisions affecting planned parenthood, and 4) prepare a list of lawyers and legal reformers by country. The panel has 1) recommended adoption of an IPPF Central Medical Committee and Central Law Panel statement on sterilization, adolescent fertility control, and the use of medical and auxiliary personnel in family planning services with guidelines for Africa; 2) appointed National Legal Correspondents to carry on the monitoring service mentioned above in 18 countries; and 3) discussed solutions to problems in delivering family planning services with family planning associations in Tanzania, Zambia, Mauritius, Madagascar, and Kenya. Laws governing family planning education and services, marriage, divorce, and maternity benefits in these countries are summarized. In 1978 the panel will hold 2 workshops on law and the status of women.

  16. Paneling architectural freeform surfaces

    KAUST Repository

    Eigensatz, Michael; Kilian, Martin; Schiftner, Alexander; Mitra, Niloy J.; Pottmann, Helmut; Pauly, Mark

    2010-01-01

    The emergence of large-scale freeform shapes in architecture poses big challenges to the fabrication of such structures. A key problem is the approximation of the design surface by a union of patches, socalled panels, that can be manufactured with a

  17. Photovoltaic-Panel Laminator

    Science.gov (United States)

    Keenan, R.

    1985-01-01

    Two-piece unit heats and presses protective layers to form laminate. Rubber diaphragm between upper and lower vacuum chambers alternates between neutral position and one that presses against solar-cell array, supplying distributed force necessary to press layers of laminate together. Encapsulation helps to protect cells from environment and to ensure long panel life while allowing efficient generation of electricity from Sunlight.

  18. Dynamic panel data models

    NARCIS (Netherlands)

    Bun, M.J.G.; Sarafidis, V.

    2013-01-01

    This Chapter reviews the recent literature on dynamic panel data models with a short time span and a large cross-section. Throughout the discussion we considerlinear models with additional endogenous covariates. First we give a broad overview of available inference methods placing emphasis on GMM.

  19. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, surgery, ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, surgery, ...

  20. Composite panel development at JPL

    Science.gov (United States)

    Mcelroy, Paul; Helms, Rich

    1988-01-01

    Parametric computer studies can be use in a cost effective manner to determine optimized composite mirror panel designs. An InterDisciplinary computer Model (IDM) was created to aid in the development of high precision reflector panels for LDR. The materials properties, thermal responses, structural geometries, and radio/optical precision are synergistically analyzed for specific panel designs. Promising panels designs are fabricated and tested so that comparison with panel test results can be used to verify performance prediction models and accommodate design refinement. The iterative approach of computer design and model refinement with performance testing and materials optimization has shown good results for LDR panels.

  1. Aerospace Safety Advisory Panel

    Science.gov (United States)

    1999-01-01

    This report covers the activities of the Aerospace Safety Advisory Panel (ASAP) for calendar year 1998-a year of sharp contrasts and significant successes at NASA. The year opened with the announcement of large workforce cutbacks. The slip in the schedule for launching the International Space Station (ISS) created a five-month hiatus in Space Shuttle launches. This slack period ended with the successful and highly publicized launch of the STS-95 mission. As the year closed, ISS assembly began with the successful orbiting and joining of the Functional Cargo Block (FGB), Zarya, from Russia and the Unity Node from the United States. Throughout the year, the Panel maintained its scrutiny of NASA's safety processes. Of particular interest were the potential effects on safety of workforce reductions and the continued transition of functions to the Space Flight Operations Contractor. Attention was also given to the risk management plans of the Aero-Space Technology programs, including the X-33, X-34, and X-38. Overall, the Panel concluded that safety is well served for the present. The picture is not as clear for the future. Cutbacks have limited the depth of talent available. In many cases, technical specialties are 'one deep.' The extended hiring freeze has resulted in an older workforce that will inevitably suffer significant departures from retirements in the near future. The resulting 'brain drain' could represent a future safety risk unless appropriate succession planning is started expeditiously. This and other topics are covered in the section addressing workforce. The major NASA programs are also limited in their ability to plan property for the future. This is of particular concern for the Space Shuttle and ISS because these programs are scheduled to operate well into the next century. In the case of the Space Shuttle, beneficial and mandatory safety and operational upgrades are being delayed because of a lack of sufficient present funding. Likewise, the ISS has

  2. Semiconductor-based, large-area, flexible, electronic devices on {110} oriented substrates

    Science.gov (United States)

    Goyal, Amit

    2014-08-05

    Novel articles and methods to fabricate the same resulting in flexible, oriented, semiconductor-based, electronic devices on {110} textured substrates are disclosed. Potential applications of resulting articles are in areas of photovoltaic devices, flat-panel displays, thermophotovoltaic devices, ferroelectric devices, light emitting diode devices, computer hard disc drive devices, magnetoresistance based devices, photoluminescence based devices, non-volatile memory devices, dielectric devices, thermoelectric devices and quantum dot laser devices.

  3. [100] or [110] aligned, semiconductor-based, large-area, flexible, electronic devices

    Science.gov (United States)

    Goyal, Amit

    2015-03-24

    Novel articles and methods to fabricate the same resulting in flexible, large-area, [100] or [110] textured, semiconductor-based, electronic devices are disclosed. Potential applications of resulting articles are in areas of photovoltaic devices, flat-panel displays, thermophotovoltaic devices, ferroelectric devices, light emitting diode devices, computer hard disc drive devices, magnetoresistance based devices, photoluminescence based devices, non-volatile memory devices, dielectric devices, thermoelectric devices and quantum dot laser devices.

  4. {100} or 45.degree.-rotated {100}, semiconductor-based, large-area, flexible, electronic devices

    Science.gov (United States)

    Goyal, Amit [Knoxville, TN

    2012-05-15

    Novel articles and methods to fabricate the same resulting in flexible, {100} or 45.degree.-rotated {100} oriented, semiconductor-based, electronic devices are disclosed. Potential applications of resulting articles are in areas of photovoltaic devices, flat-panel displays, thermophotovoltaic devices, ferroelectric devices, light emitting diode devices, computer hard disc drive devices, magnetoresistance based devices, photoluminescence based devices, non-volatile memory devices, dielectric devices, thermoelectric devices and quantum dot laser devices.

  5. Panel and planar experimental shear behavior of wood panels ...

    African Journals Online (AJOL)

    Panel shear strength along the thickness and planar shear along the length of wood panels laminated softwood oriented OSB 10 mm thick, conditioned at different moisture contents (anhydrous medium, ambient temperature and humid medium) was measured on standardized test specimens, cut in half lengthwise panel ...

  6. FEMA DFIRM Panel Scheme Polygons

    Data.gov (United States)

    Minnesota Department of Natural Resources — This layer contains information about the Flood Insurance Rate Map (FIRM) panel areas. The spatial entities representing FIRM panels are polygons. The polygon for...

  7. Report of Industry Panel Group

    Science.gov (United States)

    Gallimore, Simon; Gier, Jochen; Heitland, Greg; Povinelli, Louis; Sharma, Om; VandeWall, Allen

    2006-01-01

    A final report is presented from the industry panel group. The contents include: 1) General comments; 2) Positive progress since Minnowbrook IV; 3) Industry panel outcome; 4) Prioritized turbine projects; 5) Prioritized compressor projects; and 6) Miscellaneous.

  8. A new device for intraoperative renal blood flow measurement during open-heart surgery: an experimental study and the clinical pilot study.

    Science.gov (United States)

    Tirilomis, Theodor; Popov, Aron F; Hanekop, Gunnar G; Braeuer, Anselm; Quintel, Michael; Schoendube, Friedrich A; Friedrich, Martin G

    2013-10-01

    Renal blood flow (RBF) may vary during cardiopulmonary bypass and low flow may cause insufficient blood supply of the kidney triggering renal failure postoperatively. Still, a valid intraoperative method of continuous RBF measurement is not available. A new catheter combining thermodilution and intravascular Doppler was developed, first calibrated in an in vitro model, and the catheter specific constant was determined. Then, application of the device was evaluated in a pilot study in an adult cardiovascular population. The data of the clinical pilot study revealed high correlation between the flow velocities detected by intravascular Doppler and the RBF measured by thermodilution (Pearson's correlation range: 0.78 to 0.97). In conclusion, the RBF can be measured excellently in real time using the new catheter, even under cardiopulmonary bypass. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  9. Mounting clips for panel installation

    Science.gov (United States)

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph

    2017-07-11

    A photovoltaic panel mounting clip comprising a base, central indexing tabs, flanges, lateral indexing tabs, and vertical indexing tabs. The mounting clip removably attaches one or more panels to a beam or the like structure, both mechanically and electrically. It provides secure locking of the panels in all directions, while providing guidance in all directions for accurate installation of the panels to the beam or the like structure.

  10. Experience with citizens panels

    International Nuclear Information System (INIS)

    Selwyn, J.

    2002-01-01

    In May 1999, 200 delegates attended a four-day UK Consensus Conference on radioactive waste management, which was organised by the UK Centre for Economic and Environmental Development (UK CEED) and supported by the government, industry and environmental groups. The event brought together a Citizens' Panel of fifteen people, randomly selected to represent a cross section of the British public, together with the major players in the debate. The four-day conference saw the panel cross-examine expert witnesses from organisations such as NIREX, British Nuclear Fuels Limited, the Ministry of Defence, Greenpeace and Friends of the Earth. The findings of their investigations were put together in a report containing detailed recommendations for government and industry and presented to the Minister on the final day. (author)

  11. Robotic surgery

    Science.gov (United States)

    ... with this type of surgery give it some advantages over standard endoscopic techniques. The surgeon can make ... Elsevier Saunders; 2015:chap 87. Muller CL, Fried GM. Emerging technology in surgery: Informatics, electronics, robotics. In: ...

  12. Nose Surgery

    Science.gov (United States)

    ... Patient Health Home Copyright © 2018 American Academy of Otolaryngology–Head and Neck Surgery. Reproduction or republication strictly ... Terms of Use © Copyright 2018. American Academy of Otolaryngology — Head and Neck Surgery 1650 Diagonal Rd Alexandria, ...

  13. After Surgery

    Science.gov (United States)

    ... side effects. There is usually some pain with surgery. There may also be swelling and soreness around ... the first few days, weeks, or months after surgery. Some other questions to ask are How long ...

  14. Color quality management in advanced flat panel display engines

    Science.gov (United States)

    Lebowsky, Fritz; Neugebauer, Charles F.; Marnatti, David M.

    2003-01-01

    During recent years color reproduction systems for consumer needs have experienced various difficulties. In particular, flat panels and printers could not reach a satisfactory color match. The RGB image stored on an Internet server of a retailer did not show the desired colors on a consumer display device or printer device. STMicroelectronics addresses this important color reproduction issue inside their advanced display engines using novel algorithms targeted for low cost consumer flat panels. Using a new and genuine RGB color space transformation, which combines a gamma correction Look-Up-Table, tetrahedrization, and linear interpolation, we satisfy market demands.

  15. Thyroid Surgery

    Science.gov (United States)

    ... Hypothyroidism in Children and Adolescents Pediatric Differentiated Thyroid Cancer Thyroid Nodules in Children and Adolescents Thyroid Surgery Resources Thyroid Surgery Brochure PDF Thyroid Surgery FAQs PDF En Español Cirugia De La Tiroides El folleto de Cirugia De La Tiroides Search Thyroid ...

  16. Panel data analysis using EViews

    CERN Document Server

    Agung, I Gusti Ngurah

    2013-01-01

    A comprehensive and accessible guide to panel data analysis using EViews software This book explores the use of EViews software in creating panel data analysis using appropriate empirical models and real datasets. Guidance is given on developing alternative descriptive statistical summaries for evaluation and providing policy analysis based on pool panel data. Various alternative models based on panel data are explored, including univariate general linear models, fixed effect models and causal models, and guidance on the advantages and disadvantages of each one is given. Panel Data Analysis

  17. Lightweight, Thermally Insulating Structural Panels

    Science.gov (United States)

    Eisen, Howard J.; Hickey, Gregory; Wen, Liang-Chi; Layman, William E.; Rainen, Richard A.; Birur, Gajanana C.

    1996-01-01

    Lightweight, thermally insulating panels that also serve as structural members developed. Honeycomb-core panel filled with low-thermal-conductivity, opacified silica aerogel preventing convection and minimizes internal radiation. Copper coating on face sheets reduces radiation. Overall thermal conductivities of panels smaller than state-of-art commercial non-structurally-supporting foam and fibrous insulations. On Earth, panels suitable for use in low-air-pressure environments in which lightweight, compact, structurally supporting insulation needed; for example, aboard high-altitude aircraft or in partially evacuated panels in refrigerators.

  18. Large thermal protection system panel

    Science.gov (United States)

    Weinberg, David J. (Inventor); Myers, Franklin K. (Inventor); Tran, Tu T. (Inventor)

    2003-01-01

    A protective panel for a reusable launch vehicle provides enhanced moisture protection, simplified maintenance, and increased temperature resistance. The protective panel includes an outer ceramic matrix composite (CMC) panel, and an insulative bag assembly coupled to the outer CMC panel for isolating the launch vehicle from elevated temperatures and moisture. A standoff attachment system attaches the outer CMC panel and the bag assembly to the primary structure of the launch vehicle. The insulative bag assembly includes a foil bag having a first opening shrink fitted to the outer CMC panel such that the first opening and the outer CMC panel form a water tight seal at temperatures below a desired temperature threshold. Fibrous insulation is contained within the foil bag for protecting the launch vehicle from elevated temperatures. The insulative bag assembly further includes a back panel coupled to a second opening of the foil bag such that the fibrous insulation is encapsulated by the back panel, the foil bag, and the outer CMC panel. The use of a CMC material for the outer panel in conjunction with the insulative bag assembly eliminates the need for waterproofing processes, and ultimately allows for more efficient reentry profiles.

  19. Thermal insulating panel

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, J.T.

    1985-09-11

    A panel of thermal insulation material has at least one main portion which comprises a dry particulate insulation material compressed within a porous envelope so that it is rigid or substantially rigid and at least one auxiliary portion which is secured to and extends along at least one of the edges of the main portions. The auxiliary portions comprise a substantially uncompressed dry particulate insulation material contained within an envelope. The insulation material of the auxiliary portion may be the same as or may be different from the insulation material of the main portion. The envelope of the auxiliary portion may be made of a porous or a non-porous material. (author).

  20. Concentrating photovoltaic solar panel

    Science.gov (United States)

    Cashion, Steven A; Bowser, Michael R; Farrelly, Mark B; Hines, Braden E; Holmes, Howard C; Johnson, Jr., Richard L; Russell, Richard J; Turk, Michael F

    2014-04-15

    The present invention relates to photovoltaic power systems, photovoltaic concentrator modules, and related methods. In particular, the present invention features concentrator modules having interior points of attachment for an articulating mechanism and/or an articulating mechanism that has a unique arrangement of chassis members so as to isolate bending, etc. from being transferred among the chassis members. The present invention also features adjustable solar panel mounting features and/or mounting features with two or more degrees of freedom. The present invention also features a mechanical fastener for secondary optics in a concentrator module.

  1. Photovoltaic panel clamp

    Science.gov (United States)

    Mittan, Margaret Birmingham [Oakland, CA; Miros, Robert H. J. [Fairfax, CA; Brown, Malcolm P [San Francisco, CA; Stancel, Robert [Loss Altos Hills, CA

    2012-06-05

    A photovoltaic panel clamp includes an upper and lower section. The interface between the assembled clamp halves and the module edge is filled by a flexible gasket material, such as EPDM rubber. The gasket preferably has small, finger like protrusions that allow for easy insertion onto the module edge while being reversed makes it more difficult to remove them from the module once installed. The clamp includes mounting posts or an integral axle to engage a bracket. The clamp also may include a locking tongue to secure the clamp to a bracket.

  2. Front panel human interface for FASTBUS

    International Nuclear Information System (INIS)

    Gustavson, D.B.; Holmes, T.L.; Paffrath, L.; Steffani, J.P.

    1980-01-01

    A human interface based on the Snoop diagnostic module has been designed to facilitate checkout of FASTBUS devices, diagnosis of system faults, and monitoring of system performance. This system, which is a generalization of the usual computer front panel or control console, includes logic analyzer functions, display and manual-control access to other modules, a microprocessor which allows the user to create and execute diagnostic programs and store them on a minifloppy disk, and a diagnostic network which allows remote console operation and coordination of information from multiple segments' Snoops

  3. Viscoless microincision cataract surgery

    Directory of Open Access Journals (Sweden)

    Guy Sallet

    2008-06-01

    Full Text Available Guy SalletDepartment of Opthamology, Aalsters Stedelijk Ziekenhuis, BelgiumAbstract: A cataract surgery technique is described in which incisions, continuous circular capsulorhexis and hydrodissection are made without the use of any viscoelastics. Two small incisions are created through which the different parts of the procedure can take place, maintaining a stable anterior chamber under continuous irrigation. Subsequent bimanual phacoemulsification can be done through these microincisions. At the end of the procedure, an intraocular lens can be inserted through the self-sealing incision under continuous irrigation. 50 consecutive cataract patients were operated on without the use of viscoelastics and then compared with a group of 50 patients who had been helped with viscoelastics. No difference in outcome, endothelial cell count or pachymetry was noted between the two groups. No intraoperative complication was encountered. Viscoless cataract surgery was a safe procedure with potential advantages.Keywords: ophthalmic visco-surgical device, viscoless cataract surgery, microincision

  4. Reliability Study in Solar Panels

    OpenAIRE

    Español Lifante, Albert

    2012-01-01

    Crystalline silicon Modules are formed by single silicon photovoltaic cells. Since each one of these cells individually contributes to the overall electric power of the panel, the failure of one of them directly affects to its benefits and performance. To Minimize these negative effects, junction boxes with few bypass diodes are usually included in Photovoltaic Solar panels. A still experimental way to built solar panels is to integrate bypass diodes in every single cell, which would in...

  5. Suboccipital neuropathy after bone conduction device placement

    NARCIS (Netherlands)

    Faber, H.T.; Ru, J.A. de

    2013-01-01

    OBJECTIVE: To describe the clinical characteristics of a 70-year-old female with occipital neuropathy following bone conduction device surgery. DESCRIPTION: A 65-year-old woman underwent bone conduction device placement surgery on the left temporal bone. Postoperatively she progressively developed

  6. Estimating capacity of solar thermoelectric generator (STEG) panels

    International Nuclear Information System (INIS)

    Kokhova, I.I.; Malevskii, Yu.N.; Tsvetkov, A.I.

    1979-01-01

    Energy characteristics of a solar thermoelectric generator (STEG) panel without solar-flux concentration are considered. The design of such devices is no simple task. Several fully justified assumptions have been introduced in an attempt to obtain a solution convenient for engineering calculations

  7. ALDS 1978 panel review. [PNL

    Energy Technology Data Exchange (ETDEWEB)

    Hall, D.L. (ed.)

    1979-08-01

    Pacific Northwest Laboratory (PNL) is examining the analysis of large data sets (ALDS). After one year's work, a panel was convened to evaluate the project. This document is the permanent record of that panel review. It consists of edited transcripts of presentations made to the panel by the PNL staff, a summary of the responses of the panel to these presentations, and PNL's plans for the development of the ALDS project. The representations of the PNL staff described various aspects of the project and/or the philosophy surrounding the project. Supporting materials appear in appendixes. 20 figures, 4 tables. (RWR)

  8. 37 CFR 251.2 - Purpose of Copyright Arbitration Royalty Panels.

    Science.gov (United States)

    2010-07-01

    ... carrier royalty fees and digital audio recording devices and media payments deposited with the Register of... Arbitration Royalty Panels. 251.2 Section 251.2 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT ARBITRATION ROYALTY PANEL RULES AND PROCEDURES COPYRIGHT ARBITRATION ROYALTY...

  9. 78 FR 76993 - Defense Federal Acquisition Regulation Supplement: Photovoltaic Devices (DFARS Case 2014-D006)

    Science.gov (United States)

    2013-12-20

    ... DFARS, some questions have arisen as to where the substantial transformation of some solar panels occurs... contract exceeds $25,000, the Offeror's certification that such photovoltaic device (e.g., solar panel) is...

  10. Proficiency testing for sensory profile panels : measuring panel performance

    NARCIS (Netherlands)

    Mcewan, J.A.; Hunter, E.A.; Gemert, L.J. van; Lea, P.

    2002-01-01

    Proficiency testing in sensory analysis is an important step towards demonstrating that results from one sensory panel are consistent with the results of other sensory panels. The uniqueness of sensory analysis poses some specific problems for measuring the proficiency of the human instrument

  11. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... out more. Corrective Jaw Surgery Corrective Jaw Surgery Orthognathic surgery is performed to correct the misalignment of jaws ... out more. Corrective Jaw Surgery Corrective Jaw Surgery Orthognathic surgery is performed to correct the misalignment of jaws ...

  12. Panel summary report

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Previous Advisory Group Meetings have led to IAEA Technical Reports No.15=5 (1974) on thermal discharge, 118 (1970) and 169 (1975) on sampling, storage and analysis methods for marine radioactivity studies, 167 (1975) on design of marine biological studies permitting comparative evaluation, and 172 (1976) on the effects of ionizing radiation on aquative organisms and eco-systems. The aim of the present report was a bringing into perspective not only problems designing radioecological experiments but to describe reliable experimental methodology suitable for a successful evaluation of radioactivity cycling, and of the effects of such radioactive additions to aquatic environments, as a result of nuclear activities. Specific examples are described. Individual studies presented to the Panel have been treated in detail, and constitute 19 separate INIS entries

  13. GENERAL SURGERY

    African Journals Online (AJOL)

    in the endoscopy room. GENERAL SURGERY. T du Toit, O C Buchel, S J A Smit. Department of Surgery, University of the Free State, Bloemfontein, ... The lack of video instrumentation in developing countries: Redundant fibre-optic instruments (the old. “eye scope”) are still being used. This instrument brings endoscopists ...

  14. GENERAL SURGERY

    African Journals Online (AJOL)

    mean time to first surgery post burn was 11.5 days with a median volume of 0.73 mls/kg/% ..... Mode. Mean (SD). Upper limit. 95% CI. Lower limit. 95% CI. Mode. Elective surgery .... evaluating single-unit red blood cell transfusions in reducing.

  15. Choosing surgery

    DEFF Research Database (Denmark)

    Thorstensson, Carina; Lohmander, L; Frobell, Richard

    2009-01-01

    -depth qualitative interviews were conducted with young (aged 18-35), physically active individuals with ACL rupture who were participating in a RCT comparing training and surgical reconstruction with training only. 22/34 were randomised to training only but crossed over to surgery. Of these, 11 were interviewed......ABSTRACT: BACKGROUND: The objective was to understand patients' views of treatment after acute anterior cruciate ligament (ACL) injury, and their reasons for deciding to request surgery despite consenting to participate in a randomised controlled trial (to 'cross-over'). METHODS: Thirty-four in...... before surgery, and 11 were interviewed at least 6 months after surgery. To provide additional information, 12 patients were interviewed before randomisation. Interviews were audio-recorded, transcribed and analysed using the Framework approach. RESULTS: Strong preference for surgery was commonplace...

  16. Flat-panel detectors: how much better are they?

    International Nuclear Information System (INIS)

    Seibert, J.A.

    2006-01-01

    Interventional and fluoroscopic imaging procedures for pediatric patients are becoming more prevalent because of the less-invasive nature of these procedures compared to alternatives such as surgery. Flat-panel X-ray detectors (FPD) for fluoroscopy are a new technology alternative to the image intensifier/TV (II/TV) digital system that has been in use for more than two decades. Two major FPD technologies have been implemented, based on indirect conversion of X-rays to light (using an X-ray scintillator) and then to proportional charge (using a photodiode), or direct conversion of X-rays into charge (using a semiconductor material) for signal acquisition and digitization. These detectors have proved very successful for high-exposure interventional procedures but lack the image quality of the II/TV system at the lowest exposure levels common in fluoroscopy. The benefits for FPD image quality include lack of geometric distortion, little or no veiling glare, a uniform response across the field-of-view, and improved ergonomics with better patient access. Better detective quantum efficiency indicates the possibility of reducing the patient dose in accordance with ALARA principles. However, first-generation FPD devices have been implemented with less than adequate acquisition flexibility (e.g., lack of tableside controls/information, inability to easily change protocols) and the presence of residual signals from previous exposures, and additional cost of equipment and long-term maintenance have been serious impediments to purchase and implementation. Technological advances of second generation and future hybrid FPD systems should solve many current issues. The answer to the question ''how much better are they?'' is ''significantly better'', and they are certainly worth consideration for replacement or new implementation of an imaging suite for pediatric fluoroscopy. (orig.)

  17. A Novel Lighting OLED Panel Design

    Directory of Open Access Journals (Sweden)

    Enyang Zhang

    2016-11-01

    Full Text Available A novel OLED (organic light emitting diode lighting panel, which uses a special layout design, can reduce the photolithography cycles and process costs and is more reliable. It only needs two steps of photolithography cycles, which include an ITO (InSnO compound transparent oxide pattern and insulator pattern. There is no need for the metal bus pattern of the ordinary design. The OLED device structure is a type of red–green–blue (RGB-stacked emitting layer that has a good color index and greater adjustability, which improves the performance of the device. This novel design has the same equipment and material requirement compared to the ordinary design, and it is very beneficial in terms of high volume and low-cost production. It uses a hyper driving method because the entire OLED lighting panel is divided into many sub-emitting units; if one of the sub-emitting units is burned out, it has no effect on the adjacent sub-emitting unit, so the reliability is markedly better than the ordinary design.

  18. Strong increase of solar panels

    International Nuclear Information System (INIS)

    Segers, R.; Janssen, S.

    2012-01-01

    The number of installed solar panels in 2011 has increased again. 40 megawatt of new panels have been installed. This increase is twice as high as the year before. The production of solar power increased to 90 million kWh in 2011 as a result of this expansion. However, the share of solar power in total energy use is still very limited. [nl

  19. Panel Smooth Transition Regression Models

    DEFF Research Database (Denmark)

    González, Andrés; Terasvirta, Timo; Dijk, Dick van

    We introduce the panel smooth transition regression model. This new model is intended for characterizing heterogeneous panels, allowing the regression coefficients to vary both across individuals and over time. Specifically, heterogeneity is allowed for by assuming that these coefficients are bou...

  20. Matlab Software for Spatial Panels

    NARCIS (Netherlands)

    Elhorst, J.Paul

    2014-01-01

    Elhorst provides Matlab routines to estimate spatial panel data models at his website. This article extends these routines to include the bias correction procedure proposed by Lee and Yu if the spatial panel data model contains spatial and/or time-period fixed effects, the direct and indirect

  1. Applications of piezoelectric surgery in endodontic surgery: a literature review.

    Science.gov (United States)

    Abella, Francesc; de Ribot, Joan; Doria, Guillermo; Duran-Sindreu, Fernando; Roig, Miguel

    2014-03-01

    Piezosurgery (piezoelectric bone surgery) devices were developed to cut bone atraumatically using ultrasonic vibrations and to provide an alternative to the mechanical and electrical instruments used in conventional oral surgery. Indications for piezosurgery are increasing in oral and maxillofacial surgery, as in other disciplines, such as endodontic surgery. Key features of piezosurgery instruments include their ability to selectively cut bone without damaging adjacent soft tissue, to provide a clear operative field, and to cut without generating heat. Although piezosurgery instruments can be used at most stages of endodontic surgery (osteotomy, root-end resection, and root-end preparation), no published data are available on the effect of piezosurgery on the outcomes of endodontic surgery. To our knowledge, no study has evaluated the effect of piezosurgery on root-end resection, and only 1 has investigated root-end morphology after retrograde cavity preparation using piezosurgery. We conducted a search of the PubMed and Cochrane databases using appropriate terms and keywords related to the use and applications of piezoelectric surgery in endodontic surgery. A hand search also was conducted of issues published in the preceding 2 years of several journals. Two independent reviewers obtained and analyzed the full texts of the selected articles. A total of 121 articles published between January 2000 and December 2013 were identified. This review summarizes the operating principles of piezoelectric devices and outlines the applications of piezosurgery in endodontic surgery using clinical examples. Piezosurgery is a promising technical modality with applications in several aspects of endodontic surgery, but further studies are necessary to determine the influence of piezosurgery on root-end resection and root-end preparation. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. Mounting clips for panel installation

    Science.gov (United States)

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph; Valdes, Francisco

    2017-02-14

    An exemplary mounting clip for removably attaching panels to a supporting structure comprises a base, spring locking clips, a lateral flange, a lever flange, and a spring bonding pad. The spring locking clips extend upwardly from the base. The lateral flange extends upwardly from a first side of the base. The lateral flange comprises a slot having an opening configured to receive at least a portion of one of the one or more panels. The lever flange extends outwardly from the lateral flange. The spring bonding flange extends downwardly from the lever flange. At least a portion of the first spring bonding flange comprises a serrated edge for gouging at least a portion of the one or more panels when the one or more panels are attached to the mounting clip to electrically and mechanically couple the one or more panels to the mounting clip.

  3. Stress Testing of Organic Light- Emitting Diode Panels and Luminaires

    Energy Technology Data Exchange (ETDEWEB)

    Lynn Davis, Kelley Rountree, Karmann Mills

    2018-01-31

    This report builds on previous DOE efforts with OLED technology by updating information on a previously benchmarked OLED product (the Chalina luminaire from Acuity Brands) and provides new benchmarks on the performance of Brite 2 and Brite Amber OLED panels from OLEDWorks. During the tests described here, samples of these devices were subjected to continuous operation in stress tests at elevated ambient temperature environments of 35°C or 45°C. In addition, samples were also operated continuously at room temperature in a room temperature operational life test (RTOL). One goal of this study was to investigate whether these test conditions can accelerate failure of OLED panels, either through panel shorting or an open circuit in the panel. These stress tests are shown to provide meaningful acceleration of OLED failure modes, and an acceleration factor of 2.6 was calculated at 45°C for some test conditions. In addition, changes in the photometric properties of the emitted light (e.g., luminous flux and chromaticity maintenance) was also evaluated for insights into the long-term stability of these products compared to earlier generations. Because OLEDs are a lighting system, electrical testing was also performed on the panel-driver pairs to provide insights into the impact of the driver on long-term panel performance.

  4. Temperature Dependences on Various Types of Photovoltaic (PV) Panel

    International Nuclear Information System (INIS)

    Audwinto, I A; Leong, C S; Sopian, K; Zaidi, S H

    2015-01-01

    Temperature is one of the key roles in PV technology performance, since with the increases of temperature the open-circuit voltage will drop accordingly so do the electrical efficiency and power output generation. Different types of Photovoltaic (PV) panels- silicon solar panels and thin film solar panels; mono-crystalline, poly-crystalline, CIS, CIGS, CdTe, back-contact, and bi-facial solar panel under 40°C to 70°C approximately with 5°C interval have been comparatively analyzed their actual performances with uniformly distribution of light illumination from tungsten halogen light source, ±500W/m 2 . DC-Electronic Load and Data Logger devices with “Lab View” data program interface were used to collect all the necessary parameters in this study. Time needed to achieve a certain degree of temperature was recorded. Generally, each of the panels needed 15 minutes to 20 minutes to reach 70°C. Halogen based light source is not compatible in short wave-length in response to thin-film solar cell. Within this period of times, all the panels are facing a performance loss up to 15%. Other parameters; P max , V max , I max , V oc , I sc , R serries , R shunt , Fillfactor were collected as study cases. Our study is important in determining Photovoltaic type selection and system design as for study or industrial needed under different temperature condition. (paper)

  5. Panel discussion: Nuclear cardiology

    International Nuclear Information System (INIS)

    Schwaiger, M.

    1991-01-01

    The panel discussion opened with a question concerning whether true quantification of myocardial sympathetic presynaptic function or receptor density can be obtained with currently available radiopharmaceuticals. What are the relative advantages of the two general approaches that have been proposed for quantification: (1) The assessment of tracer distribution volume in tissue following bolus injection and (2) quantification based on tracer displacement kinetics following administration of excess unlabeled tracer. It was pointed out that tracer kinetics for the delineation of presynaptic and postsynaptic binding sites by radiopharmaceuticals or radiolabeled receptor antagonists are rather complex, reflecting several physiologic processes that are difficult to separate. Several approaches were examined. The possibility of regional definition of receptor density by PET was questioned and it was noted that regions of interest can be applied to calculate regional receptor kinetics. However, due to the limited spatial resolution of PET, only average transmural values can be determined. The discussion then turned to the discrepancy between the known sparse parasympathetic innervation of the heart and the high density of muscarinic receptors observed with PET. Experiences with MIBG imaging were reported, including uptake in the transplanted heart and interaction of drugs with MIBG uptake

  6. Cataract Surgery

    Science.gov (United States)

    ... Oncology Oculoplastics/Orbit Refractive Management/Intervention Retina/Vitreous Uveitis Focus On Pediatric Ophthalmology ... Are Cataracts? Pediatric Cataracts Cataract Diagnosis and Treatment Cataract Surgery IOL Implants: Lens Replacement After Cataracts ...

  7. Brain surgery

    Science.gov (United States)

    Craniotomy; Surgery - brain; Neurosurgery; Craniectomy; Stereotactic craniotomy; Stereotactic brain biopsy; Endoscopic craniotomy ... cut depends on where the problem in the brain is located. The surgeon creates a hole in ...

  8. Foot Surgery

    Science.gov (United States)

    ... coding trends along with compliance guidelines and practice marketing materials, APMA has you covered whether you are ... crutches after the surgery or in a cast. Fusions: Fusions are usually performed to treat arthritic or ...

  9. Hemorrhoid surgery

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002939.htm Hemorrhoid surgery To use the sharing features on this page, please enable JavaScript. Hemorrhoids are swollen veins around the anus. They may ...

  10. PLASTIC SURGERY

    African Journals Online (AJOL)

    Department of Plastic and Reconstructive Surgery Sefako Makgatho Health Science University, ... We report on a pilot study on the use of a circumareolar excision and the use of .... and 1 gynecomastia patient) requested reduction in NAC size.

  11. GENERAL SURGERY

    African Journals Online (AJOL)

    influence medical students in pursuing a career in surgery. ... training, females reported significantly higher levels of agreement that surgical training would be better overseas when ..... mentoring surgical research or educational lectures and.

  12. GENERAL SURGERY

    African Journals Online (AJOL)

    1 Department of Surgery, Nelson R Mandela School of Medicine, University of ... in 51 reports. Four reports were illegible; one was conducted by a junior consultant, two by a fourth year trainee specialist ... The study period was 12 months from.

  13. Sinus Surgery

    Science.gov (United States)

    ... sinus computed tomography (CT) scan (without contrast), nasal physiology (rhinomanometry and nasal cytology), smell testing, and selected ... altered anatomical landmarks, or where a patient’s sinus anatomy is very unusual, making typical surgery difficult. Image ...

  14. Pressurized waterproof case for electronic device

    KAUST Repository

    Berumen, Michael L.

    2013-01-01

    having an open top panel or face covered by a flexible, transparent membrane or the like for the operation of the touch-screen device within the case. A pressurizing system is provided for the case to pressurize the case and the electronic device therein

  15. Emergency surgery

    DEFF Research Database (Denmark)

    Stoneham, M; Murray, D; Foss, N

    2014-01-01

    National reports recommended that peri-operative care should be improved for elderly patients undergoing emergency surgery. Postoperative mortality and morbidity rates remain high, and indicate that emergency ruptured aneurysm repair, laparotomy and hip fracture fixation are high-risk procedures...... undertaken on elderly patients with limited physiological reserve. National audits have reported variations in care quality, data that are increasingly being used to drive quality improvement through professional guidance. Given that the number of elderly patients presenting for emergency surgery is likely...

  16. 1994 Panel 1 Utilization Plan

    International Nuclear Information System (INIS)

    1994-01-01

    The Waste Isolation Pilot Plant (WIPP) is intended to receive, handle, and permanently dispose of transuranic (TRU) waste. To fulfill this mission, the U.S. Department of Energy (DOE) constructed a full-scale facility to demonstrate both technical and operational principles of the permanent isolation of TRU waste. The WIPP consists of surface and underground facilities. Panel 1 is situated in the underground facility horizon which is located approximately 2,150 feet below the surface in the predominantly halite Salado Formation. The Panel 1 Utilization Plan provides a strategy for the optimum use of Panel 1 which is consistent with the priorities established by the DOE to accomplish the WIPP mission. These priorities, which include maintaining personnel safety, conducting performance assessment, and continued operational enhancements, are the guiding premise for the decisions on the planned usage of the WIPP underground facility. The continuation of ongoing investigations along with the planned testing and training to be carried out in Panel 1 will enhance the current knowledge and understanding of the operational and geotechnical aspects of the panel configuration. This enhancement will ultimately lead to safer, more efficient, and more cost-effective methods of operation. Excavation of the waste storage area began in May 1986 with the mining of entries to Panel 1. The original design for the waste storage rooms at the WIPP provided a limited period of time during which to mine the openings and to emplace waste. Each panel, consisting of seven storage rooms, was scheduled to be mined and filled in less than 5 years. Panel 1 was developed to receive waste for a demonstration phase that was scheduled to start in October 1988. The demonstration phase was deferred, and the experimental test program was modified to use contact-handled (CH) transuranic waste in bin-scale tests, planned for Room 1, Panel 1

  17. Panel Speaker 3

    Science.gov (United States)

    Doering, Robert

    2014-03-01

    Profitable products are frequently enabled by innovations that prevent early commoditization. At its best, industrial physics research provides the key differentiators for such products. To fulfill this goal, it's necessary to establish effective working relationships between R&D staff with both physics and engineering backgrounds. In the semiconductor industry, the ``middle ground'' is often materials science, electromagnetics, or a wide range of phenomena useful for creating sensors. In this brief presentation, we will mention a few examples of such collaborative development at Texas Instruments, including MEMS devices, ferroelectric memory, and silicon-IC-based radar.

  18. Integrated control rod monitoring device

    International Nuclear Information System (INIS)

    Saito, Katsuhiro

    1997-01-01

    The present invention provides a device in which an entire control rod driving time measuring device and a control rod position support device in a reactor building and a central control chamber are integrated systematically to save hardwares such as a signal input/output device and signal cables between boards. Namely, (1) functions of the entire control rod driving time measuring device for monitoring control rods which control the reactor power and a control rod position indication device are integrated into one identical system. Then, the entire devices can be made compact by the integration of the functions. (2) The functions of the entire control rod driving time measuring device and the control rod position indication device are integrated in a central operation board and a board in the site. Then, the place for the installation of them can be used in common in any of the cases. (3) The functions of the entire control rod driving time measuring device and the control rod position indication device are integrated to one identical system to save hardware to be used. Then, signal input/output devices and drift branching panel boards in the site and the central operation board can be saved, and cables for connecting both of the boards is no more necessary. (I.S.)

  19. Cochlear implant revision surgeries in children.

    Science.gov (United States)

    Amaral, Maria Stella Arantes do; Reis, Ana Cláudia Mirândola B; Massuda, Eduardo T; Hyppolito, Miguel Angelo

    2018-02-16

    The surgery during which the cochlear implant internal device is implanted is not entirely free of risks and may produce problems that will require revision surgeries. To verify the indications for cochlear implantation revision surgery for the cochlear implant internal device, its effectiveness and its correlation with certain variables related to language and hearing. A retrospective study of patients under 18 years submitted to cochlear implant Surgery from 2004 to 2015 in a public hospital in Brazil. Data collected were: age at the time of implantation, gender, etiology of the hearing loss, audiological and oral language characteristics of each patient before and after Cochlear Implant surgery and any need for surgical revision and the reason for it. Two hundred and sixty-five surgeries were performed in 236 patients. Eight patients received a bilateral cochlear implant and 10 patients required revision surgery. Thirty-two surgeries were necessary for these 10 children (1 bilateral cochlear implant), of which 21 were revision surgeries. In 2 children, cochlear implant removal was necessary, without reimplantation, one with cochlear malformation due to incomplete partition type I and another due to trauma. With respect to the cause for revision surgery, of the 8 children who were successfully reimplanted, four had cochlear calcification following meningitis, one followed trauma, one exhibited a facial nerve malformation, one experienced a failure of the cochlear implant internal device and one revision surgery was necessary because the electrode was twisted. The incidence of the cochlear implant revision surgery was 4.23%. The period following the revision surgeries revealed an improvement in the subject's hearing and language performance, indicating that these surgeries are valid in most cases. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  20. DC current distribution mapping system of the solar panels using a HTS-SQUID gradiometer

    International Nuclear Information System (INIS)

    Miyazaki, Shingo; Kasuya, Syohei; Saari, Mohd Mawardi; Sakai, Kenji; Kiwa, Toshihiko; Tsukada, Keiji; Tsukamoto, Akira; Adachi, Seiji; Tanabe, Keiichi

    2014-01-01

    Solar panels are expected to play a major role as a source of sustainable energy. In order to evaluate solar panels, non-destructive tests, such as defect inspections and response property evaluations, are necessary. We developed a DC current distribution mapping system of the solar panels using a High Critical Temperature Superconductor Superconducting Quantum Interference Device (HTS-SQUID) gradiometer with ramp edge type Josephson junctions. Two independent components of the magnetic fields perpendicular to the panel surface (∂Bz/∂x, ∂Bz/∂y) were detected. The direct current of the solar panel is visualized by calculating the composition of the two signal components, the phase angle, and mapping the DC current vector. The developed system can evaluate the uniformity of DC current distributions precisely and may be applicable for defect detection of solar panels.

  1. Tennis elbow surgery

    Science.gov (United States)

    Lateral epicondylitis - surgery; Lateral tendinosis - surgery; Lateral tennis elbow - surgery ... Surgery to repair tennis elbow is often an outpatient surgery. This means you will not stay in the hospital overnight. You will be given ...

  2. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... and Craniofacial Surgery Cleft Lip/Palate and Craniofacial Surgery A cleft lip may require one or more ... find out more. Corrective Jaw Surgery Corrective Jaw Surgery Orthognathic surgery is performed to correct the misalignment ...

  3. Mohs micrographic surgery

    Science.gov (United States)

    Skin cancer - Mohs surgery; Basal cell skin cancer - Mohs surgery; Squamous cell skin cancer - Mohs surgery ... Mohs surgery usually takes place in the doctor's office. The surgery is started early in the morning and is ...

  4. Exascale Workshop Panel Report Meeting

    Energy Technology Data Exchange (ETDEWEB)

    Khaleel, Mohammad A.

    2010-07-01

    The Exascale Review Panel consists of 12 scientists and engineers with experience in various aspects of high-performance computing and its application, development, and management. The Panel hear presentations by several representatives of the workshops and town meetings convened over the past few years to examine the need for exascale computation capability and the justification for a U.S. Department of Energy (DOE) program to develop such capability. This report summarizes information provided by the presenters and substantial written reports to the Panel in advance of the meeting in Washington D.C. on January 19-20, 2010. The report also summarizes the Panel's conclusions with regard to the justification of a DOE-led exascale initiative.

  5. Cleaning Robot for Solar Panels in Solar Power Station

    Science.gov (United States)

    Hang, Lu-Bin; Shen, Cheng-Wei; Bian, Huai-Qiang; Wang, Yan

    2016-05-01

    The dust particles on solar panel surface have been a serious problem for the photovoltaic industry, a new monorail-tracked robot used for automatic cleaning of solar panel is presented in this paper. To meet the requirement of comprehensive and stable cleaning of PV array, the monorail-tracked pattern of robot is introduced based on the monorail structure technique. The running and striding mechanism are designed for mobility of robot on the solar panels. According to the carrying capacity and water circulation mechanism, a type of self-cleaning device with filtering system is developed. Combined with the computer software and communications technology, the control system is built in this robot, which can realize the functions of autonomous operation, positioning and monitoring. The application of this developed cleaning robot can actualize the Industrialization of automatic cleaning for PV components and have wide market prospect.

  6. Orthognathic Surgery

    DEFF Research Database (Denmark)

    Kjærgaard Larsen, Marie; Thygesen, Torben Henrik

    2016-01-01

    The literature shows that the indications for orthognathic surgery (OS) are often functional problems and unsatisfactory facial esthetics. This study investigated the esthetic outcomes and overall satisfaction following OS. Somatosensory change is a relatively common complication and its influence...... on the level of satisfaction was studied. The social-networking web site Facebook was used to identify the study population. An online questionnaire was performed using the website SurveyMonkey. In all, 105 (9%) respondents from the Danish Facebook group about OS, called Kaebeoperation (jaw surgery), were...... in beauty than women (P = 0.030). Sixty-four percent replied that their attractiveness had been increased after OS. Eighty-six percent were happy with the results and 89% would recommend the surgery to others in need. No significant differences in esthetic results and satisfaction were seen with regard...

  7. Intestinal Surgery.

    Science.gov (United States)

    Desrochers, André; Anderson, David E

    2016-11-01

    A wide variety of disorders affecting the intestinal tract in cattle may require surgery. Among those disorders the more common are: intestinal volvulus, jejunal hemorrhage syndrome and more recently the duodenal sigmoid flexure volvulus. Although general principles of intestinal surgery can be applied, cattle has anatomical and behavior particularities that must be known before invading the abdomen. This article focuses on surgical techniques used to optimize outcomes and discusses specific disorders of small intestine. Diagnoses and surgical techniques presented can be applied in field conditions. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Large-area high-efficiency flexible PHOLED lighting panels

    Science.gov (United States)

    Pang, Huiqing; Mandlik, Prashant; Levermore, Peter A.; Silvernail, Jeff; Ma, Ruiqing; Brown, Julie J.

    2012-09-01

    Organic Light Emitting Diodes (OLEDs) provide various attractive features for next generation illumination systems, including high efficiency, low power, thin and flexible form factor. In this work, we incorporated phosphorescent emitters and demonstrated highly efficient white phosphorescent OLED (PHOLED) devices on flexible plastic substrates. The 0.94 cm2 small-area device has total thickness of approximately 0.25 mm and achieved 63 lm/W at 1,000 cd/m2 with CRI = 85 and CCT = 2920 K. We further designed and fabricated a 15 cm x 15 cm large-area flexible white OLED lighting panels, finished with a hybrid single-layer ultra-low permeability single layer barrier (SLB) encapsulation film. The flexible panel has an active area of 116.4 cm2, and achieved a power efficacy of 47 lm/W at 1,000 cd/m2 with CRI = 83 and CCT = 3470 K. The efficacy of the panel at 3,000 cd/m2 is 43 lm/W. The large-area flexible PHOLED lighting panel is to bring out enormous possibilities to the future general lighting applications.

  9. Pressurized waterproof case electronic device

    KAUST Repository

    Berumen, Michael L.

    2013-01-31

    A pressurized waterproof case for an electronic device is particularly adapted for fluid-tight containment and operation of a touch-screen electronic device or the like therein at some appreciable water depth. In one example, the case may be formed as an enclosure having an open top panel or face covered by a flexible, transparent membrane or the like for the operation of the touchscreen device within the case. A pressurizing system is provided for the case to pressurize the case and the electronic device therein to slightly greater than ambient in order to prevent the external water pressure from bearing against the transparent membrane and pressing it against the touch screen, thereby precluding operation of the touch screen device within the case. The pressurizing system may include a small gas cartridge or may be provided from an external source.

  10. GENERAL SURGERY

    African Journals Online (AJOL)

    surgery. Since the first laparoscopic treatment of hydatid disease was described in 1992,14 there has been a steady growth in reports of the laparoscopic treatment of hydatid cysts of liver. Although early reported laparoscopic treatment of liver hydatid disease was confined to simple drainage, more advanced laparoscopic ...

  11. GENERAL SURGERY

    African Journals Online (AJOL)

    Department of Surgery, University of Cape Town Health Sciences Faculty, Groote Schuur Hospital, Observatory, Cape Town,. South Africa ... included all district, regional and tertiary hospitals in the nine provinces. Clinics and so-called ..... large contingency of senior general surgeons from countries such as Cuba, who have ...

  12. TRAUMA SURGERY

    African Journals Online (AJOL)

    meet the criteria for damage control surgery, and ligation of the AVC is a .... There were two vertebral body fractures, one penetrating brain injury from a gunshot wound to the head, one ... two hand fractures, three haemothoraces, one pelvic fracture, .... One patient with an intimal flap injury to his left common iliac artery ...

  13. GENERAL SURGERY

    African Journals Online (AJOL)

    Schwab , using a three-phase approach.5 In 1998, Moore et al. extended the concept and described the five-stage approach.6. The aim of damage control surgery is to prevent severely injured patients from developing the “lethal triad” of hypothermia, coagulopathy and worsening acidosis, as this confers a dismal prognosis ...

  14. Rodding Surgery

    Science.gov (United States)

    ... Physical activity prior to surgery,  Length of the operation; anesthesia issues,  Reason for the choice of rod,  Time in the hospital,  Length of recovery time at home,  Pain management including control of muscle spasms,  The rehabilitation plan. ...

  15. High temperature structural sandwich panels

    Science.gov (United States)

    Papakonstantinou, Christos G.

    High strength composites are being used for making lightweight structural panels that are being employed in aerospace, naval and automotive structures. Recently, there is renewed interest in use of these panels. The major problem of most commercial available sandwich panels is the fire resistance. A recently developed inorganic matrix is investigated for use in cases where fire and high temperature resistance are necessary. The focus of this dissertation is the development of a fireproof composite structural system. Sandwich panels made with polysialate matrices have an excellent potential for use in applications where exposure to high temperatures or fire is a concern. Commercial available sandwich panels will soften and lose nearly all of their compressive strength temperatures lower than 400°C. This dissertation consists of the state of the art, the experimental investigation and the analytical modeling. The state of the art covers the performance of existing high temperature composites, sandwich panels and reinforced concrete beams strengthened with Fiber Reinforced Polymers (FRP). The experimental part consists of four major components: (i) Development of a fireproof syntactic foam with maximum specific strength, (ii) Development of a lightweight syntactic foam based on polystyrene spheres, (iii) Development of the composite system for the skins. The variables are the skin thickness, modulus of elasticity of skin and high temperature resistance, and (iv) Experimental evaluation of the flexural behavior of sandwich panels. Analytical modeling consists of a model for the flexural behavior of lightweight sandwich panels, and a model for deflection calculations of reinforced concrete beams strengthened with FRP subjected to fatigue loading. The experimental and analytical results show that sandwich panels made with polysialate matrices and ceramic spheres do not lose their load bearing capability during severe fire exposure, where temperatures reach several

  16. The Use of PCs, Smartphones, and Tablets in a Probability-Based Panel Survey : Effects on Survey Measurement Error

    NARCIS (Netherlands)

    Lugtig, Peter; Toepoel, Vera

    2016-01-01

    Respondents in an Internet panel survey can often choose which device they use to complete questionnaires: a traditional PC, laptop, tablet computer, or a smartphone. Because all these devices have different screen sizes and modes of data entry, measurement errors may differ between devices. Using

  17. Carotid artery surgery

    Science.gov (United States)

    Carotid endarterectomy; CAS surgery; Carotid artery stenosis - surgery; Endarterectomy - carotid artery ... through the catheter around the blocked area during surgery. Your carotid artery is opened. The surgeon removes ...

  18. 3D Printed Composites for Topology Transforming Multifunctional Devices

    Science.gov (United States)

    2017-01-26

    panels connected by hinges, which occupy infinitesimal space but control the angles between two panels. Figure 2.2.1-3 shows panels are connected by...observations that higher curing temperature yields to more compacted and better connected silver NPs. The Young’s moduli, however, are lower than that of...AFRL-AFOSR-VA-TR-2017-0021 3D Printed Composites for Topology -Transforming Multifunctional Devices Kurt Maute REGENTS OF THE UNIVERSITY OF COLORADO

  19. Diffractive flat panel solar concentrators of a novel design.

    Science.gov (United States)

    de Jong, Ties M; de Boer, Dick K G; Bastiaansen, Cees W M

    2016-07-11

    A novel design for a flat panel solar concentrator is presented which is based on a light guide with a grating applied on top that diffracts light into total internal reflection. By combining geometrical and diffractive optics the geometrical concentration ratio is optimized according to the principles of nonimaging optics, while the thickness of the device is minimized due to the use of total internal reflection.

  20. 78 FR 9010 - Dental Devices; Reclassification of Temporary Mandibular Condyle Prosthesis

    Science.gov (United States)

    2013-02-07

    .... FDA-2012-N-1239] Dental Devices; Reclassification of Temporary Mandibular Condyle Prosthesis AGENCY... condyle prostheses into class III, based on the recommendation of a Dental Products Panel (the Panel... Administration, Dental Products Advisory Panel Meeting Transcript, February 12, 1997; http://www.accessdata.fda...

  1. Solar Panel based Milk Pasteurization

    DEFF Research Database (Denmark)

    Nielsen, Kirsten Mølgaard; Pedersen, Tom Søndergaard

    This paper treats the subject of analysis, design and development of the control system for a solar panel based milk pasteurization system to be used in small villages in Tanzania. The analysis deals with the demands for an acceptable pasteurization, the varying energy supply and the low cost, low...... complexity, simple user interface and high reliability demands. Based on these demands a concept for the pasteurization system is established and a control system is developed. A solar panel has been constructed and the energy absorption has been tested in Tanzania. Based on the test, the pasteurization...... system is dimensioned. A functional prototype of the pasteurization facility with a capacity of 200 l milk/hour has been developed and tested. The system is prepared for solar panels as the main energy source and is ready for a test in Tanzania....

  2. Solar Panel based Milk Pasteurization

    DEFF Research Database (Denmark)

    Nielsen, Kirsten Mølgaard; Pedersen, Tom Søndergaard

    2002-01-01

    This paper treats the subject of analysis, design and development of the control system for a solar panel based milk pasteurization system to be used in small villages in Tanzania. The analysis deals with the demands for an acceptable pasteurization, the varying energy supply and the low cost, low...... complexity, simple user interface and high reliability demands. Based on these demands a concept for the pasteurization system is established and a control system is developed. A solar panel has been constructed and the energy absorption has been tested in Tanzania. Based on the test, the pasteurization...... system is dimensioned. A functional prototype of the pasteurization facility with a capacity of 200 l milk/hour has been developed and tested. The system is prepared for solar panels as the main energy source and is ready for a test in Tanzania....

  3. Metabolic Surgery

    DEFF Research Database (Denmark)

    Pareek, Manan; Schauer, Philip R; Kaplan, Lee M

    2018-01-01

    The alarming rise in the worldwide prevalence of obesity is paralleled by an increasing burden of type 2 diabetes mellitus. Metabolic surgery is the most effective means of obtaining substantial and durable weight loss in individuals with obesity. Randomized trials have recently shown...... the superiority of surgery over medical treatment alone in achieving improved glycemic control, as well as a reduction in cardiovascular risk factors. The mechanisms seem to extend beyond the magnitude of weight loss alone and include improvements in incretin profiles, insulin secretion, and insulin sensitivity....... Moreover, observational data suggest that the reduction in cardiovascular risk factors translates to better patient outcomes. This review describes commonly used metabolic surgical procedures and their current indications and summarizes the evidence related to weight loss and glycemic outcomes. It further...

  4. Preparing for Surgery

    Science.gov (United States)

    ... Events Advocacy For Patients About ACOG Preparing for Surgery Home For Patients Search FAQs Preparing for Surgery ... Surgery FAQ080, August 2011 PDF Format Preparing for Surgery Gynecologic Problems What is the difference between outpatient ...

  5. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... Extractions and Other Oral Surgeries Extractions and Other Oral Surgeries Oral and maxillofacial surgeons surgically treat the soft ... Extractions and Other Oral Surgeries Extractions and Other Oral Surgeries Oral and maxillofacial surgeons surgically treat the soft ...

  6. Corrective Jaw Surgery

    Science.gov (United States)

    ... Extractions and Other Oral Surgeries Extractions and Other Oral Surgeries Oral and maxillofacial surgeons surgically treat the soft ... Extractions and Other Oral Surgeries Extractions and Other Oral Surgeries Oral and maxillofacial surgeons surgically treat the soft ...

  7. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... to find out more. Facial Cosmetic Surgery Facial Cosmetic Surgery Extensive education and training in surgical procedures ... to find out more. Facial Cosmetic Surgery Facial Cosmetic Surgery Extensive education and training in surgical procedures ...

  8. Facial Cosmetic Surgery

    Science.gov (United States)

    ... to find out more. Facial Cosmetic Surgery Facial Cosmetic Surgery Extensive education and training in surgical procedures ... to find out more. Facial Cosmetic Surgery Facial Cosmetic Surgery Extensive education and training in surgical procedures ...

  9. Heart bypass surgery

    Science.gov (United States)

    Off-pump coronary artery bypass; OPCAB; Beating heart surgery; Bypass surgery - heart; CABG; Coronary artery bypass graft; Coronary artery bypass surgery; Coronary bypass surgery; Coronary artery disease - CABG; CAD - CABG; Angina - ...

  10. Solar panel truss mounting systems and methods

    Energy Technology Data Exchange (ETDEWEB)

    Al-Haddad, Tristan Farris; Cavieres, Andres; Gentry, Russell; Goodman, Joseph; Nolan, Wade; Pitelka, Taylor; Rahimzadeh, Keyan; Brooks, Bradley; Lohr, Joshua; Crooks, Ryan; Porges, Jamie; Rubin, Daniel

    2016-06-28

    An exemplary embodiment of the present invention provides a solar panel truss mounting system comprising a base and a truss assembly coupled to the base. The truss assembly comprises a first panel rail mount, second panel rail mount parallel to the first panel rail mount, base rail mount parallel to the first and second panel rail mounts, and a plurality of support members. A first portion of the plurality of support members extends between the first and second panel rail mounts. A second portion of the plurality of support members extends between the first panel rail mount and the base rail mount. A third portion of the plurality of support members extends between the second panel rail mount and the base rail mount. The system can further comprise a plurality of connectors for coupling a plurality of photovoltaic solar panels to the truss assembly.

  11. Solar panel truss mounting systems and methods

    Energy Technology Data Exchange (ETDEWEB)

    Al-Haddad, Tristan Farris; Cavieres, Andres; Gentry, Russell; Goodman, Joseph; Nolan, Wade; Pitelka, Taylor; Rahimzadeh, Keyan; Brooks, Bradley; Lohr, Joshua; Crooks, Ryan; Porges, Jamie; Rubin, Daniel

    2018-01-30

    An exemplary embodiment of the present invention provides a solar panel truss mounting system comprising a base and a truss assembly coupled to the base. The truss assembly comprises a first panel rail mount, second panel rail mount parallel to the first panel rail mount, base rail mount parallel to the first and second panel rail mounts, and a plurality of support members. A first portion of the plurality of support members extends between the first and second panel rail mounts. A second portion of the plurality of support members extends between the first panel rail mount and the base rail mount. A third portion of the plurality of support members extends between the second panel rail mount and the base rail mount. The system can further comprise a plurality of connectors for coupling a plurality of photovoltaic solar panels to the truss assembly.

  12. Solar panel truss mounting systems and methods

    Science.gov (United States)

    Al-Haddad, Tristan Farris; Cavieres, Andres; Gentry, Russell; Goodman, Joseph; Nolan, Wade; Pitelka, Taylor; Rahimzadeh, Keyan; Brooks, Bradley; Lohr, Joshua; Crooks, Ryan; Porges, Jamie; Rubin, Daniel

    2015-10-20

    An exemplary embodiment of the present invention provides a solar panel truss mounting system comprising a base and a truss assembly coupled to the base. The truss assembly comprises a first panel rail mount, second panel rail mount parallel to the first panel rail mount, base rail mount parallel to the first and second panel rail mounts, and a plurality of support members. A first portion of the plurality of support members extends between the first and second panel rail mounts. A second portion of the plurality of support members extends between the first panel rail mount and the base rail mount. A third portion of the plurality of support members extends between the second panel rail mount and the base rail mount. The system can further comprise a plurality of connectors for coupling a plurality of photovoltaic solar panels to the truss assembly.

  13. Photovoltaic device

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Jason A; Keenihan, James R; Gaston, Ryan S; Kauffmann, Keith L; Langmaid, Joseph A; Lopez, Leonardo; Maak, Kevin D; Mills, Michael E; Ramesh, Narayan; Teli, Samar R

    2017-03-21

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  14. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-06-02

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device with a multilayered photovoltaic cell assembly and a body portion joined at an interface region and including an intermediate layer, at least one interconnecting structural member, relieving feature, unique component geometry, or any combination thereof.

  15. Photovoltaic device

    Science.gov (United States)

    Reese, Jason A.; Keenihan, James R.; Gaston, Ryan S.; Kauffmann, Keith L.; Langmaid, Joseph A.; Lopez, Leonardo C.; Maak, Kevin D.; Mills, Michael E.; Ramesh, Narayan; Teli, Samar R.

    2015-09-01

    The present invention is premised upon an improved photovoltaic device ("PV device"), more particularly to an improved photovoltaic device (10) with a multilayered photovoltaic cell assembly (100) and a body portion (200) joined at an interface region (410) and including an intermediate layer (500), at least one interconnecting structural member (1500), relieving feature (2500), unique component geometry, or any combination thereof.

  16. A review of sensing technologies for small and large-scale touch panels

    Science.gov (United States)

    Akhtar, Humza; Kemao, Qian; Kakarala, Ramakrishna

    2017-06-01

    A touch panel is an input device for human computer interaction. It consists of a network of sensors, a sampling circuit and a micro controller for detecting and locating a touch input. Touch input can come from either finger or stylus depending upon the type of touch technology. These touch panels provide an intuitive and collaborative workspace so that people can perform various tasks with the use of their fingers instead of traditional input devices like keyboard and mouse. Touch sensing technology is not new. At the time of this writing, various technologies are available in the market and this paper reviews the most common ones. We review traditional designs and sensing algorithms for touch technology. We also observe that due to its various strengths, capacitive touch will dominate the large-scale touch panel industry in years to come. In the end, we discuss the motivation for doing academic research on large-scale panels.

  17. 2010 Panel on the Biomaterials Grand Challenges

    Science.gov (United States)

    Reichert, William “Monty”; Ratner, Buddy D.; Anderson, James; Coury, Art; Hoffman, Allan S.; Laurencin, Cato T.; Tirrell, David

    2014-01-01

    In 2009, the National Academy for Engineering issued the Grand Challenges for Engineering in the 21st Century comprised of 14 technical challenges that must be addressed to build a healthy, profitable, sustainable, and secure global community (http://www.engineeringchallenges.org). Although crucial, none of the NEA Grand Challenges adequately addressed the challenges that face the biomaterials community. In response to the NAE Grand Challenges, Monty Reichert of Duke University organized a panel entitled Grand Challenges in Biomaterials at the at the 2010 Society for Biomaterials Annual Meeting in Seattle. Six members of the National Academies—Buddy Ratner, James Anderson, Allan Hoffman, Art Coury, Cato Laurencin, and David Tirrell—were asked to propose a grand challenge to the audience that, if met, would significantly impact the future of biomaterials and medical devices. Successfully meeting these challenges will speed the 60-plus year transition from commodity, off-the-shelf biomaterials to bioengineered chemistries, and biomaterial devices that will significantly advance our ability to address patient needs and also to create new market opportunities. PMID:21171147

  18. Mobile response in web panels

    NARCIS (Netherlands)

    de Bruijne, M.A.; Wijnant, A.

    2014-01-01

    This article investigates unintended mobile access to surveys in online, probability-based panels. We find that spontaneous tablet usage is drastically increasing in web surveys, while smartphone usage remains low. Further, we analyze the bias of respondent profiles using smartphones and tablets

  19. Keuringspanele ("Screening Panels") as Gepaste ...

    African Journals Online (AJOL)

    In this particular article attention is paid to screening panels as pre-trial mechanism with the exclusive purpose to select malpractice disputes, discourage unfounded disputes and to encourage an early settlement in case of a prima facie case. Several objections have been raised by critics in this regard, for instance, ...

  20. ASIST 2003: Part II: Panels.

    Science.gov (United States)

    Proceedings of the ASIST Annual Meeting, 2003

    2003-01-01

    Forty-six panels address topics including women in information science; users and usability; information studies; reference services; information policies; standards; interface design; information retrieval; information networks; metadata; shared access; e-commerce in libraries; knowledge organization; information science theories; digitization;…

  1. Risk-based decisionmaking (Panel)

    Energy Technology Data Exchange (ETDEWEB)

    Smith, T.H.

    1995-12-31

    By means of a panel discussion and extensive audience interaction, explore the current challenges and progress to date in applying risk considerations to decisionmaking related to low-level waste. This topic is especially timely because of the proposed legislation pertaining to risk-based decisionmaking and because of the increased emphasis placed on radiological performance assessments of low-level waste disposal.

  2. Steam/water separation device for drying a wet vapour

    International Nuclear Information System (INIS)

    Sundheimer, P.

    1986-01-01

    The aim of the present invention is to dry a wet vapour which flows up to the device. The device has at least a group of steam dryer elements in a zone in which there is a vertical apertured panel; this vertical apertured panel is a metal grille with baffles the inlet steam flow to make it horizontal or slightly inclined to the bottom. The invention applies more particularly, to PWR steam generators [fr

  3. El Salvador - Rural Electrification - Solar Panels

    Data.gov (United States)

    Millennium Challenge Corporation — This is a summative qualitative performance evaluation (PE) of the solar panel component of the solar panel component of the RE Sub-Activity. The final report will...

  4. Installation package for concentrating solar collector panels

    Science.gov (United States)

    1978-01-01

    The concentrating solar collector panels comprise a complete package array consisting of collector panels using modified Fresnel prismatic lenses for a 10 to 1 concentrating ratio, supporting framework, fluid manifolding and tracking drive system, and unassembled components for field erection.

  5. Retaining Ring Fastener for Solar Panels

    Science.gov (United States)

    Wilson, A. H.

    1983-01-01

    Simple articulating linkage secures solar panels into supporting framework. Five element linkage collapses into W-shape for easy placement into framework, then expands to form rectangle of same dimensions as those of panel.

  6. Mycobacterium chimaera left ventricular assist device infections.

    Science.gov (United States)

    Balsam, Leora B; Louie, Eddie; Hill, Fred; Levine, Jamie; Phillips, Michael S

    2017-06-01

    A global outbreak of invasive Mycobacterium chimaera infections after cardiac surgery has recently been linked to bioaerosols from contaminated heater-cooler units. The majority of cases have occurred after valvular surgery or aortic graft surgery and nearly half have resulted in death. To date, infections in patients with left ventricular assist devices (LVADs) have not been characterized in the literature. We report two cases of device-associated M. chimaera infection in patients with continuous-flow LVADs and describe challenges related to diagnosis and management in this population. © 2017 Wiley Periodicals, Inc.

  7. PV panel model based on datasheet values

    DEFF Research Database (Denmark)

    Sera, Dezso; Teodorescu, Remus; Rodriguez, Pedro

    2007-01-01

    This work presents the construction of a model for a PV panel using the single-diode five-parameters model, based exclusively on data-sheet parameters. The model takes into account the series and parallel (shunt) resistance of the panel. The equivalent circuit and the basic equations of the PV cell....... Based on these equations, a PV panel model, which is able to predict the panel behavior in different temperature and irradiance conditions, is built and tested....

  8. Grounds of two positions photovoltaic panels

    OpenAIRE

    Castán Fortuño, Fernando

    2008-01-01

    The objective of this Master Thesis is to find the optimum positioning for a two positions photovoltaic panel. Hence, it will be implemented a model in order to optimize the energy of the sun that the photovoltaic panel is receiving by its positioning. Likewise this project will include the comparison with other photovoltaic panel systems as the single position photovoltaics panels. Ultimately, it is also going to be designed a system array for the optimized model of two positions photovoltai...

  9. Sealing device

    Science.gov (United States)

    Garcia-Crespo, Andres Jose

    2013-12-10

    A sealing device for sealing a gap between a dovetail of a bucket assembly and a rotor wheel is disclosed. The sealing device includes a cover plate configured to cover the gap and a retention member protruding from the cover plate and configured to engage the dovetail. The sealing device provides a seal against the gap when the bucket assemply is subjected to a centrifugal force.

  10. Microfluidic Device

    Science.gov (United States)

    Tai, Yu-Chong (Inventor); Zheng, Siyang (Inventor); Lin, Jeffrey Chun-Hui (Inventor); Kasdan, Harvey L. (Inventor)

    2017-01-01

    Described herein are particular embodiments relating to a microfluidic device that may be utilized for cell sensing, counting, and/or sorting. Particular aspects relate to a microfabricated device that is capable of differentiating single cell types from dense cell populations. One particular embodiment relates a device and methods of using the same for sensing, counting, and/or sorting leukocytes from whole, undiluted blood samples.

  11. Gauging device

    International Nuclear Information System (INIS)

    Qurnell, F.D.; Patterson, C.B.

    1979-01-01

    A gauge supporting device for measuring say a square tube comprises a pair of rods or guides in tension between a pair of end members, the end members being spaced apart by a compression member or members. The tensioned guides provide planes of reference for measuring devices moved therealong on a carriage. The device is especially useful for making on site dimensional measurements of components, such as irradiated and therefore radioactive components, that cannot readily be transported to an inspection laboratory. (UK)

  12. Control panel for CMC 8080 crate controller

    International Nuclear Information System (INIS)

    Masayuki Inokuchi

    1978-01-01

    The main features of Control Panel for CAMAC Crate Controller CMC 8080 are described. The control panel can be directly connected with CRATE CONTROLLER's front panel connector with a 50 lines cable without any changes in CMC 8080 system circuits. (author)

  13. 78 FR 63501 - Meetings of Humanities Panel

    Science.gov (United States)

    2013-10-24

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Meetings of Humanities Panel AGENCY: National Endowment for the Humanities. ACTION: Notice of meetings. SUMMARY: Pursuant to section 10(a)(2) of the... Humanities Panel will be held during November, 2013 as follows. The purpose of the meetings is for panel...

  14. 78 FR 74175 - Meetings of Humanities Panel

    Science.gov (United States)

    2013-12-10

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Meetings of Humanities Panel AGENCY: National Endowment for the Humanities. ACTION: Notice of meetings. SUMMARY: Pursuant to section 10(a)(2) of the... Humanities Panel will be held during January 2014 as follows. The purpose of the meetings is for panel review...

  15. Solar panel assembly and support pad

    Energy Technology Data Exchange (ETDEWEB)

    Hawley, W.W.

    1980-10-07

    A solar panel assembly is described comprising at least one solar panel, support means for carrying said panel, and at least one support pad having a base plate, upstanding longitudinal sides, and spaced apart flange means for connection to said support means, said upstanding sides and opposed flange means defining an interior volume for receiving and holding weighting material.

  16. Flat panel planar optic display

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T. [Brookhaven National Lab., Upton, NY (United States). Dept. of Advanced Technology

    1994-11-01

    A prototype 10 inch flat panel Planar Optic Display, (POD), screen has been constructed and tested. This display screen is comprised of hundreds of planar optic class sheets bonded together with a cladding layer between each sheet where each glass sheet represents a vertical line of resolution. The display is 9 inches wide by 5 inches high and approximately 1 inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  17. Panel 4 - applications to transportation

    Energy Technology Data Exchange (ETDEWEB)

    Nichols, F. [Argonne National Lab., IL (United States); Au, J. [Sundstrand Aerospace, Rockford, IL (United States); Bhattacharya, R. [Universal Energy Systems, Inc., Dayton, OH (United States); Bhushan, B. [Ohio State Univ., Columbus (United States); Blunier, D. [Caterpillar, Inc., Peoria, IL (United States); Boardman, B. [Deere & Co., Moline, IL (United States); Brombolich, L. [Compu-Tec Engineering, Chesterfield, MO (United States); Davidson, J. [Vanderbilt Univ., Nashville, TN (United States); Graham, M. [Northwestern Univ., Evanston, IL (United States); Hakim, N. [Detroit Diesel Corp., MI (United States); Harris, K. [Dubbeldee Harris Diamond Corp., Mt. Arlington, NJ (United States); Hay, R. [Norton Diamond Film, Northboro, MA (United States); Herk, L. [Southwest Research Inst., Southfield, MI (United States); Hojnacki, H.; Rourk, D. [Intelligent Structures Incorporated, Canton, MI (United States); Kamo, R. [Adiabatics, Inc., Columbus, IN (United States); Nieman, B. [Allied-Signal Inc., Des Plaines, IL (United States); O`Neill, D. [3M, St. Paul, MN (United States); Peterson, M.B. [Wear Sciences, Arnold, MD (United States); Pfaffenberger, G. [Allison Gas Turbine, Indianapolis, IN (United States); Pryor, R.W. [Wayne State Univ., Detroit, MI (United States); Russell, J. [Superconductivity Publications, Inc., Somerset, NJ (United States); Syniuta, W. [Advanced Mechanical Technology, Inc., Newton, MA (United States); Tamor, M. [Ford Motor Co., Dearborn, MI (United States); Vojnovich, T. [Dept. of Energy, Washington, DC (United States); Yarbrough, W. [Pennsylvania State Univ., University Park (United States); Yust, C.S. [Oak Ridge National Lab., TN (United States)

    1993-01-01

    The aim of this group was to compile a listing of current and anticipated future problem areas in the transportation industry where the properties of diamond and DLC films make them especially attractive and where the panel could strongly endorse the establishment of DOE/Transportation Industry cooperative research efforts. This section identifies the problem areas for possible applications of diamond/DLC technology and presents indications of current approaches to these problems.

  18. Comparisons between various cavity and panel noise reduction control in double-panel structures

    NARCIS (Netherlands)

    Ho, J.H.; Kalverboer, J.; Berkhoff, A.P.

    2012-01-01

    This paper presents comparisons between various panel and cavity resonance control methods to reduce the transmitted sound in a double-panel structure. The double-panel, which consists of two panels with air in the gap, has the advantages of low weight and effective transmission-loss at high

  19. Panel Resonance Control and Cavity Control in Double-Panel Structures for Active Noise Reduction

    NARCIS (Netherlands)

    Ho, J.; Berkhoff, Arthur P.

    2011-01-01

    An analytical and experimental investigation of panel resonance control and cavity control in a double-panel structure is presented in this paper. The double-panel structure, which consists of two panels with air in the gap, is widely adopted in many applications such as aerospace due to its low

  20. Noise Reduction in Double‿Panel Structures by Cavity and Panel Resonance Control

    NARCIS (Netherlands)

    Ho, J.; Berkhoff, Arthur P.

    2011-01-01

    This paper presents an investigation of the cavity and the panel resonance control in a double‿panel structure. The double‿panel structure, which consists of two panels with air in the gap, is widely adopted in many applications such as aerospace due to its light weight and effective

  1. Noise reduction in double-panel structures by cavity and panel resonance control

    NARCIS (Netherlands)

    Ho, J.-H.; Berkhoff, A.P

    2011-01-01

    This paper presents an investigation of the cavity and the panel resonance control in a double‐panel structure. The double‐panel structure, which consists of two panels with air in the gap, is widely adopted in many applications such as aerospace due to its light weight and effective

  2. Cavity Control and Panel Control Strategies in Double-Panel Structures for Transmitted Noise Reduction

    NARCIS (Netherlands)

    Ho, J.; Kalverboer, J.; Berkhoff, Arthur P.

    2012-01-01

    Investigation and comparisons of the cavity control and the panel control in a double-panel structure are presented in this paper. The double-panel structure, which comprises two panels with air in the gap, provides the advantages of low sound-transmission at high frequency, low heat-transmission

  3. The Role of a Mental Model in Learning to Operate a Device.

    Science.gov (United States)

    Kieras, David E.; Bovair, Susan

    1984-01-01

    Describes three studies concerned with learning to operate a control panel device and how this learning is affected by understanding a device model that describes its internal mechanism. Results indicate benefits of a device model depend on whether it supports direct inference of exact steps required to operate the device. (Author/MBR)

  4. Incore instrument device

    International Nuclear Information System (INIS)

    Sakima, Naoki

    1996-01-01

    An incore instrument device has an integrally disposed touch panel having a function of displaying an operation indication method such as for setting of conditions for incore measurement and information processing and results of the incore measurement and a function capable of conducting operation indication such as for setting conditions and information processing for incore measurement relative to a control section upon touching an information position on a displayed information. In addition, an information processing section comprising a man-machine function program formed so as to recognize the content of the operation indication for the incore measurement by touching and let the control section to conduct it is disposed to the outside by way of a communication interface. In addition, a programming device is disposed for forming and rewriting the program of the man-machine function relative to the information processing section. Then, when various indication operations are conducted upon performing incore measurement, a view point can be concentrated to one predetermined point thereby enabling to improve the operationability without danger. In addition, the programming of the man-machine function does not apply unnecessary load to the control section in the incore instrumentation device. (N.H.)

  5. Fusion devices

    International Nuclear Information System (INIS)

    Fowler, T.K.

    1977-01-01

    Three types of thermonuclear fusion devices currently under development are reviewed for an electric utilities management audience. Overall design features of laser fusion, tokamak, and magnetic mirror type reactors are described and illustrated. Thrusts and trends in current research on these devices that promise to improve performance are briefly reviewed. Twenty photographs and drawings are included

  6. BRAKE DEVICE

    Science.gov (United States)

    O'Donnell, T.J.

    1959-03-10

    A brake device is described for utilization in connection with a control rod. The device comprises a pair of parallelogram link mechanisms, a control rod moveable rectilinearly therebetween in opposite directions, and shoes resiliently supported by the mechanism for frictional engagement with the control rod.

  7. PLASMA DEVICE

    Science.gov (United States)

    Gow, J.D.; Wilcox, J.M.

    1961-12-26

    A device is designed for producing and confining highenergy plasma from which neutrons are generated in copious quantities. A rotating sheath of electrons is established in a radial electric field and axial magnetic field produced within the device. The electron sheath serves as a strong ionizing medium to gas introdueed thereto and also functions as an extremely effective heating mechanism to the resulting plasma. In addition, improved confinement of the plasma is obtained by ring magnetic mirror fields produced at the ends of the device. Such ring mirror fields are defined by the magnetic field lines at the ends of the device diverging radially outward from the axis of the device and thereafter converging at spatial annular surfaces disposed concentrically thereabout. (AFC)

  8. Flat panel display - Impurity doping technology for flat panel displays

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Toshiharu [Advanced Technology Planning, Sumitomo Eaton Nova Corporation, SBS Tower 9F, 10-1, Yoga 4-chome, Setagaya-ku, 158-0097 Tokyo (Japan)]. E-mail: suzuki_tsh@senova.co.jp

    2005-08-01

    Features of the flat panel displays (FPDs) such as liquid crystal display (LCD) and organic light emitting diode (OLED) display, etc. using low temperature poly-Si (LTPS) thin film transistors (TFTs) are briefly reviewed comparing with other FPDs. The requirements for fabricating TFTs used for high performance FPDs and system on glass (SoG) are addressed. This paper focuses on the impurity doping technology, which is one of the key technologies together with crystallization by laser annealing, formation of high quality gate insulator and gate-insulator/poly-Si interface. The issues to be solved in impurity doping technology for state of the art and future TFTs are clarified.

  9. Flat panel display - Impurity doping technology for flat panel displays

    International Nuclear Information System (INIS)

    Suzuki, Toshiharu

    2005-01-01

    Features of the flat panel displays (FPDs) such as liquid crystal display (LCD) and organic light emitting diode (OLED) display, etc. using low temperature poly-Si (LTPS) thin film transistors (TFTs) are briefly reviewed comparing with other FPDs. The requirements for fabricating TFTs used for high performance FPDs and system on glass (SoG) are addressed. This paper focuses on the impurity doping technology, which is one of the key technologies together with crystallization by laser annealing, formation of high quality gate insulator and gate-insulator/poly-Si interface. The issues to be solved in impurity doping technology for state of the art and future TFTs are clarified

  10. High Efficiency, High Density Terrestrial Panel. [for solar cell modules

    Science.gov (United States)

    Wohlgemuth, J.; Wihl, M.; Rosenfield, T.

    1979-01-01

    Terrestrial panels were fabricated using rectangular cells. Packing densities in excess of 90% with panel conversion efficiencies greater than 13% were obtained. Higher density panels can be produced on a cost competitive basis with the standard salami panels.

  11. 77 FR 42318 - Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2012-07-18

    ... generally intended as an adjunct to fusion for the treatment of degenerative disc disease (as defined by..., infection, and inflammatory disorders in the cervical spine. FDA intends to make background material... accommodated during the scheduled open public hearing session, FDA may conduct a lottery to determine the...

  12. 75 FR 4407 - The Neurological Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2010-01-27

    ... enough to provide timely notice. Therefore, you should always check the agency's Web site and call the... premarket approval application for the Deep Brain Stimulation System for Epilepsy sponsored by Medtronic...

  13. 77 FR 42503 - Ophthalmic Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2012-07-19

    ... committee meeting cannot always be published quickly enough to provide timely notice. Therefore, you should... perception, the retina must be able to respond to electrical stimulation as evidenced by an electrically...

  14. 78 FR 77689 - Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-12-24

    ... fibrosis, fluoride uptake acceleration in dentistry, and for local anesthesia of the intact tympanic... fluoride and local anesthesia of the intact tympanic membrane uses from the class II definition because it... cystic fibrosis, application of fluoride in dentistry, or anesthetizing the tympanic membrane. Based on...

  15. 78 FR 24426 - Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-04-25

    ... on FDA's regulatory issues. Date and Time: The meeting will be held on July 24 and 25, 2013, from 8 a... confirmed by patient history, physical examination, and radiographic studies. FDA intends to make background... notify the contact person and submit a brief statement of the general nature of the evidence or arguments...

  16. 77 FR 7589 - Neurological Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2012-02-13

    ... ongoing randomized clinical trial, ``Stenting and Aggressive Medical Management for Preventing Recurrent Stroke in Intracranial Stenosis'' (SAMMPRIS), published in the New England Journal of Medicine (2011;365...-0923. FDA intends to make background material available to the public no later than 2 business days...

  17. 78 FR 46977 - Ophthalmic Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2013-08-02

    ... intraoperative management of clear corneal incisions with a wound leak demonstrated by Seidel test, and for... a disability, please contact AnnMarie Williams at Annmarie.Williams@fda.hhs.gov or 301-796-5966, at...

  18. 77 FR 50701 - Radiological Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2012-08-22

    ..., sponsored by Hologic, Inc. The Selenia Dimensions 3D System is currently approved for breast cancer screening and diagnosis. The screening exam can consist of field digital mammography (FFDM) alone or the... combination of DBT with synthetic 2D images to be used as another exam option for breast cancer screening. FDA...

  19. 77 FR 19293 - Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Meeting

    Science.gov (United States)

    2012-03-30

    ... population (Ref. 3). This peer-reviewed journal article presented the following findings regarding primary Mo... resurfacing). FDA intends to make background material available to the public no later than 2 business days... Implants: A Technology Overview'' (July 15, 2011), accessed online at http://www.aaos.org/research...

  20. 76 FR 56200 - Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-09-12

    ... lesion lengths per patient of 280 mm. \\1\\ ``Fr'' stands for French. It is a term that defines the... registrants requesting to speak is greater than can be reasonably accommodated during the scheduled open... hearing session. The contact person will notify interested persons regarding their request to speak by...

  1. 78 FR 55081 - Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2013-09-09

    .... Once the Sensor is in position, the tether wires are withdrawn, releasing the Sensor. Electronics Unit (Interrogator) and database--The Electronics Unit contains hardware and software to acquire and process signals... contains software, which receives data transmitted from the electronics unit, and presents the data for...

  2. 76 FR 63928 - Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-10-14

    ..., releasing the Sensor. Electronics Unit (Interrogator) and database--The Electronics Unit contains hardware... transmitted from the electronics unit, and presents the data for review by medical professionals. FDA intends... person on or before November 30, 2011. Oral presentations from the public will be scheduled between...

  3. Tennis elbow surgery - discharge

    Science.gov (United States)

    ... epicondylitis surgery - discharge; Lateral tendinosis surgery - discharge; Lateral tennis elbow surgery - discharge ... long as you are told. This helps ensure tennis elbow will not return. You may be prescribed a ...

  4. Lung surgery - discharge

    Science.gov (United States)

    ... Lung biopsy - discharge; Thoracoscopy - discharge; Video-assisted thoracoscopic surgery - discharge; VATS - discharge ... milk) for 2 weeks after video-assisted thoracoscopic surgery and 6 to 8 weeks after open surgery. ...

  5. Gastric Sleeve Surgery

    Science.gov (United States)

    ... Videos for Educators Search English Español Gastric Sleeve Surgery KidsHealth / For Teens / Gastric Sleeve Surgery What's in ... or buying healthy food ) Preparing for Gastric Sleeve Surgery Preparing for this major operation takes months of ...

  6. Hip Replacement Surgery

    Science.gov (United States)

    ... Outreach Initiative Breadcrumb Home Health Topics English Español Hip Replacement Surgery Basics In-Depth Download Download EPUB ... PDF What is it? Points To Remember About Hip Replacement Surgery Hip replacement surgery removes damaged or ...

  7. Dental Implant Surgery

    Science.gov (United States)

    ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  8. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... here to find out more. Dental Implant Surgery Dental Implant Surgery Dental implant surgery is, of course, ... to find out more. Wisdom Teeth Management Wisdom Teeth Management An impacted wisdom tooth can damage neighboring ...

  9. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... Oral Surgeries Facial Cosmetic Surgery Facial Injury / Trauma Surgery Obstructive Sleep Apnea (OSA) Oral, Head and Neck Pathology TMJ and Facial Pain Wisdom Teeth Management Procedures Anesthesia Anesthesia Oral and maxillofacial surgeons are ...

  10. Expression of adhesion and activation molecules on lymphocytes during open-heart surgery with cardiopulmonary bypass

    DEFF Research Database (Denmark)

    Toft, P; Tønnesen, Else Kirstine; Zülow, I

    1997-01-01

    Open-heart surgery with cardiopulmonary bypass (CPB) and abdominal surgery are associated with lymphocytopenia. We measured a panel of adhesion and activation molecules on lymphocytes to clarify possible association of CPB with increased expression of these molecules. Eight patients undergoing open...

  11. Current Status of Single-incision Laparoscopic Surgery

    DEFF Research Database (Denmark)

    Ahmed, Irfan; Ciancio, Fabio; Ferrara, Vincenzo

    2012-01-01

    Recent advances in minimally invasive surgery have centered on reducing the number of incisions required, which has led to the development of the single-incision laparoscopic technique. A panel of European single-incision laparoscopy experts met to discuss the current status of, and the future...

  12. Global Surgery 2030: a roadmap for high income country actors

    Science.gov (United States)

    Greenberg, Sarah L M; Abdullah, Fizan; Amado, Vanda; Anderson, Geoffrey A; Cossa, Matchecane; Costas-Chavarri, Ainhoa; Davies, Justine; Debas, Haile T; Dyer, George S M; Erdene, Sarnai; Farmer, Paul E; Gaumnitz, Amber; Hagander, Lars; Haider, Adil; Leather, Andrew J M; Lin, Yihan; Marten, Robert; Marvin, Jeffrey T; McClain, Craig D; Meara, John G; Meheš, Mira; Mock, Charles; Mukhopadhyay, Swagoto; Orgoi, Sergelen; Prestero, Timothy; Price, Raymond R; Raykar, Nakul P; Riesel, Johanna N; Riviello, Robert; Rudy, Stephen M; Saluja, Saurabh; Sullivan, Richard; Tarpley, John L; Taylor, Robert H; Telemaque, Louis-Franck; Toma, Gabriel; Varghese, Asha; Walker, Melanie; Yamey, Gavin; Shrime, Mark G

    2016-01-01

    The Millennium Development Goals have ended and the Sustainable Development Goals have begun, marking a shift in the global health landscape. The frame of reference has changed from a focus on 8 development priorities to an expansive set of 17 interrelated goals intended to improve the well-being of all people. In this time of change, several groups, including the Lancet Commission on Global Surgery, have brought a critical problem to the fore: 5 billion people lack access to safe, affordable surgical and anaesthesia care when needed. The magnitude of this problem and the world's new focus on strengthening health systems mandate reimagined roles for and renewed commitments from high income country actors in global surgery. To discuss the way forward, on 6 May 2015, the Commission held its North American launch event in Boston, Massachusetts. Panels of experts outlined the current state of knowledge and agreed on the roles of surgical colleges and academic medical centres; trainees and training programmes; academia; global health funders; the biomedical devices industry, and news media and advocacy organisations in building sustainable, resilient surgical systems. This paper summarises these discussions and serves as a consensus statement providing practical advice to these groups. It traces a common policy agenda between major actors and provides a roadmap for maximising benefit to surgical patients worldwide. To close the access gap by 2030, individuals and organisations must work collectively, interprofessionally and globally. High income country actors must abandon colonial narratives and work alongside low and middle income country partners to build the surgical systems of the future. PMID:28588908

  13. Protected electrodes for plasma panels

    International Nuclear Information System (INIS)

    Hall, S.W.

    1984-01-01

    A metal oxide coating is applied between the conductive base and the magnesium oxide dielectric of the input and/or erase electrode(s) in a plasma display device to prevent break-down of the dielectric

  14. Laboratory panel and radiometer calibration

    CSIR Research Space (South Africa)

    Deadman, AJ

    2011-07-01

    Full Text Available stream_source_info Griffith1_2011.pdf.txt stream_content_type text/plain stream_size 16659 Content-Encoding ISO-8859-1 stream_name Griffith1_2011.pdf.txt Content-Type text/plain; charset=ISO-8859-1 LABORATORY PANEL... of Land surface imaging through a ground reference standard test site?, on http://qa4eo.org/documentation.html, 2009. [2] K. J. Thome, D. L. Helder, D. Aaron, and J. D. Dewald, ?Landsat-5 TM and Landsat-7 ETM+ Absolute Radiometric Calibration Using...

  15. Breast Reduction Surgery

    Science.gov (United States)

    ... considering breast reduction surgery, consult a board-certified plastic surgeon. It's important to understand what breast reduction surgery entails — including possible risks and complications — as ...

  16. Sealing devices

    International Nuclear Information System (INIS)

    Coulson, R.A.

    1980-01-01

    A sealing device for minimising the leakage of toxic or radioactive contaminated environments through a biological shield along an opening through which a flexible component moves that penetrates the shield. The sealing device comprises an outer tubular member which extends over a length not less than the maximum longitudinal movement of the component along the opening. An inner sealing block is located intermediate the length of the component by connectors and is positioned in the bore of the outer tubular member to slide in the bore and effect a seal over the entire longitudinal movement of the component. The cross-section of the device may be circular and the block may be of polytetrafluoroethylene or of nylon impregnated with molybdenum or may be metallic. A number of the sealing devices may be combined into an assembly for a plurality of adjacent longitudinally movable components, each adapted to sustain a tensile load, providing the various drives of a master-slave manipulator. (author)

  17. Optimum design of composite panel with photovoltaic-thermo module. Absorbing effect of cooling panel; Hikari netsu fukugo panel no saiteki sekkei. Reikyaku panel no kyunetsu koka

    Energy Technology Data Exchange (ETDEWEB)

    Sato, M; Kikuchi, S; Tani, T [Science University of Tokyo, Tokyo (Japan); Kadotani, K; Imaizumi, H [Komatsu Ltd., Tokyo (Japan)

    1996-10-27

    The composite panel with photovoltaic-thermo module becomes higher in energy-saving than the conventional air-conditioning system by the independent radiational heating and cooling effect obtained when the generating panel using a solar cell module is combined with the heating and cooling panel using a thermo-element module. The output of a solar cell module can be directly used because the solar cell module operates in AC. This paper reports the relation between the absorbed value and power consumption of the cooling panel, while paying attention to the cooling panel. The performance coefficient of the maximum absorbed value from an non-absorbing substance to a cooling panel is 2 to 3. Assume that the cooling panel during non-adiabatic operation is operated using a solar cell module of 800 W/m{sup 2} in solar intensity and 15% in conversion efficiency. The cooling-surface temperature difference is 12.12 K, and the maximum absorbed value of a non-absorbing substance to a cooling panel is 39.12 W/m{sup 2}. The absorbed value of the outer temperature to the cooling panel is 74.4 W/m{sup 2}, and each performance coefficient is 3.26 and 0.62. The absorbed value must be calculated for evaluation from the cooling-surface temperature difference measured directly from the cooling panel. 4 refs., 8 figs., 1 tab.

  18. Ferroelectric devices

    CERN Document Server

    Uchino, Kenji

    2009-01-01

    Updating its bestselling predecessor, Ferroelectric Devices, Second Edition assesses the last decade of developments-and setbacks-in the commercialization of ferroelectricity. Field pioneer and esteemed author Uchino provides insight into why this relatively nascent and interdisciplinary process has failed so far without a systematic accumulation of fundamental knowledge regarding materials and device development.Filling the informational void, this collection of information reviews state-of-the-art research and development trends reflecting nano and optical technologies, environmental regulat

  19. Investigation on a short circuit of large-area OLED lighting panels

    International Nuclear Information System (INIS)

    Park, J W; Kim, T W; Park, J B

    2013-01-01

    A short circuit often arises from large-area organic light-emitting device (OLED) lighting panels due to particles (i.e. dust, organic or metal debris) or the spike-like surface of the indium–tin–oxide (ITO) anode. On the emergence of a short circuit, an instant current crowding occurs, thereby reducing substantially the resistance of the panels and causing a failure of a dimming control. In this paper, we investigate the effect of the surface morphology of ITO on the resistance and dimmability of the panels. We have demonstrated that the peak-to-valley roughness of ITO should be much less than 20 nm or the resistance of the panels should be much higher than 1 MΩ in order to avoid an unwanted short-circuit phenomenon and thus achieve the high-yield fabrication of OLED lighting panels. It is also addressed that much care is taken to ensure a dimming control of OLED lighting panels with a larger active area because the resistance of those panels varies depending more sensitively on the surface roughness of ITO. (paper)

  20. Postradiation sarcomas: importance of surgery

    International Nuclear Information System (INIS)

    Lagrange, J.L.; Ramaioli, A.; Chateau, M.C.; Pignol, J.P.; Marchal, C.; Resbeut, M.; Richaud, P.; Rambert, P.; Tortechaux, J.; Seng, S.H.; La Fontan, B. de; Reme-Saumon, M.; Roullet, B.; Bof, J.; Coindre, J.M.

    1997-01-01

    Purpose: To evaluate the role of surgery in the treatment of Post-radiation sarcomas Materials. Post-radiation sarcomas is a rare entity and large series have rarely been reported. In order to improve knowledge about this entity the Radiotherapist group of the French Cancer Centres (FNCLCC) decided to collect retrospectively the cases treated in their institutions. In order to be sure of the histology, all the cases were reviewed by a panel of pathologists of the FNCLCC Pathologist group. A total of 129 cases of sarcomas, and 108 were reviewed; analysis of 8 is in progress, and no material was obtained in the other 11 cases. The diagnosis of sarcomas was confirmed in 80 cases. All patients (60 F, 20 M) have received radiation therapy (median dose 50 Gy; 9-110 Gy) for the treatment of the primary tumor. At this time the age was 44 years (6-83 y). Diagnoses included: breast C. 42%, Lymphomas 11.5%, gynaecological C. 10% benign lesions 5% miscellaneous. Sarcomas developed after a mean interval of 12 years (3-64 y), in bone in 30% of the cases and in soft tissue in 70%. The majority of lesions (90%) developed in the irradiated field (dose received was between 50 Gy and 60 Gy). Histologically there were 29% Malignant HistiocytofibroSarcomas, 19% OsteoSarcomas, 15% FibroSarcomas, 9% LipoSarcomas, 6% LeiomyoSarcomas, miscellaneous sarcomas 22%. Treatment included: Surgery 28 cases, Surgery+Chemotherapy 17 cases, Chemotherapy only 16 cases, Radiation therapy only 1 case, surgery + Radiation therapy 5 cases, Radiation therapy +chemotherapy 6 cases, Surgery + Radiation therapy + Chemotherapy 7 cases, no treatment 5 cases. Results. The outcome is known for all but 3 patients. 51 patients have died (44 of their sarcoma, 4 of the primary tumour, 2 of other cause and 1 iatrogenic). Median survival is 23 months (95% confidence interval 16-29 mo) but 9 patients survived 5 yr or more. Median survival was 43 mo for patients treated by surgery (28p), 6 mo for chemotherapy group (16 p

  1. Is the bipolar vessel sealer device an effective tool in robotic surgery? A retrospective analysis of our experience and a meta-analysis of the literature about different robotic procedures by investigating operative data and post-operative course.

    Science.gov (United States)

    Ortenzi, Monica; Ghiselli, Roberto; Baldarelli, Maddalena; Cardinali, Luca; Guerrieri, Mario

    2018-04-01

    The latest robotic bipolar vessel sealing tools have been described to be effective allowing to perform procedures with reduced blood loss and shorter operative times. The aim of this study was to assess the efficacy and reliability of these devices applied in different robotic procedures. All robotic operations, between 2014 and 2016, were performed using the EndoWrist One VesselSealer (EWO, Intuitive Surgical, Sunnyvale, CA), a bipolar fully wristed device. Data, including age, gender, body mass index (BMI), were collected. Robot docking time, intraoperative blood loss, robot malfunctioning and overall operative time were analyzed. A meta-analysis of the literature was carried out to point the attention to three different parameters (mean blood loss, operating time and hospital stay) trying to identify how different coagulation devices may affect them. In 73 robotic procedures, the mean operative time was 118.2 minutes (75-125 minutes). Mean hospital stay was four days (2-10 days). There were two post-operative complications (2.74%). The bipolar vessel sealer offers the efficacy of bipolar diathermy and the advantages of a fully wristed instrument. It does not require any change of instruments for coagulation or involvement of the bedside assistant surgeon. These characteristics lead to a reduction in operative time.

  2. Solar-Panel Dust Accumulation and Cleanings

    Science.gov (United States)

    2005-01-01

    Air-fall dust accumulates on the solar panels of NASA's Mars Exploration Rovers, reducing the amount of sunlight reaching the solar arrays. Pre-launch models predicted steady dust accumulation. However, the rovers have been blessed with occasional wind events that clear significant amounts of dust from the solar panels. This graph shows the effects of those panel-cleaning events on the amount of electricity generated by Spirit's solar panels. The horizontal scale is the number of Martian days (sols) after Spirit's Jan. 4, 2005, (Universal Time) landing on Mars. The vertical scale indicates output from the rover's solar panels as a fraction of the amount produced when the clean panels first opened. Note that the gradual declines are interrupted by occasional sharp increases, such as a dust-cleaning event on sol 420.

  3. Solar Panel Installations on Existing Structures

    OpenAIRE

    Tim D. Sass; Pe; Leed

    2013-01-01

    The rising price of fossil fuels, government incentives and growing public aware-ness for the need to implement sustainable energy supplies has resulted in a large in-crease in solar panel installations across the country. For many sites the most eco-nomical solar panel installation uses existing, southerly facing rooftops. Adding solar panels to an existing roof typically means increased loads that must be borne by the building-s structural elements. The structural desig...

  4. Geothermal Technologies Program Blue Ribbon Panel Recommendations

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2011-06-17

    The Geothermal Technologies Program assembled a geothermal Blue Ribbon Panel on March 22-23, 2011 in Albuquerque, New Mexico for a guided discussion on the future of geothermal energy in the United States and the role of the DOE Program. The Geothermal Blue Ribbon Panel Report captures the discussions and recommendations of the experts. An addendum is available here: http://www.eere.energy.gov/geothermal/pdfs/gtp_blue_ribbon_panel_report_addendum10-2011.pdf

  5. Sound transmission loss of composite sandwich panels

    Science.gov (United States)

    Zhou, Ran

    Light composite sandwich panels are increasingly used in automobiles, ships and aircraft, because of the advantages they offer of high strength-to-weight ratios. However, the acoustical properties of these light and stiff structures can be less desirable than those of equivalent metal panels. These undesirable properties can lead to high interior noise levels. A number of researchers have studied the acoustical properties of honeycomb and foam sandwich panels. Not much work, however, has been carried out on foam-filled honeycomb sandwich panels. In this dissertation, governing equations for the forced vibration of asymmetric sandwich panels are developed. An analytical expression for modal densities of symmetric sandwich panels is derived from a sixth-order governing equation. A boundary element analysis model for the sound transmission loss of symmetric sandwich panels is proposed. Measurements of the modal density, total loss factor, radiation loss factor, and sound transmission loss of foam-filled honeycomb sandwich panels with different configurations and thicknesses are presented. Comparisons between the predicted sound transmission loss values obtained from wave impedance analysis, statistical energy analysis, boundary element analysis, and experimental values are presented. The wave impedance analysis model provides accurate predictions of sound transmission loss for the thin foam-filled honeycomb sandwich panels at frequencies above their first resonance frequencies. The predictions from the statistical energy analysis model are in better agreement with the experimental transmission loss values of the sandwich panels when the measured radiation loss factor values near coincidence are used instead of the theoretical values for single-layer panels. The proposed boundary element analysis model provides more accurate predictions of sound transmission loss for the thick foam-filled honeycomb sandwich panels than either the wave impedance analysis model or the

  6. Case Study - Monitoring the Photovoltaic Panels

    OpenAIRE

    PACURAR Ana Talida; TOADER Dumitru; PACURAR Cristian

    2014-01-01

    The photovoltaic cell represents one of the most dynamic and attractive way to converts renewable energy sources in electricity production. That means to convert solar energy into electricity. In this paper is presented a analogy between two types of photovoltaic panels installed, with educational role for students. Also the objective of this paper is to estimate the performance of photovoltaic panels and to provide the best solution for industry. These two types of photovoltaic panels wer...

  7. Robot-assisted general surgery.

    Science.gov (United States)

    Hazey, Jeffrey W; Melvin, W Scott

    2004-06-01

    With the initiation of laparoscopic techniques in general surgery, we have seen a significant expansion of minimally invasive techniques in the last 16 years. More recently, robotic-assisted laparoscopy has moved into the general surgeon's armamentarium to address some of the shortcomings of laparoscopic surgery. AESOP (Computer Motion, Goleta, CA) addressed the issue of visualization as a robotic camera holder. With the introduction of the ZEUS robotic surgical system (Computer Motion), the ability to remotely operate laparoscopic instruments became a reality. US Food and Drug Administration approval in July 2000 of the da Vinci robotic surgical system (Intuitive Surgical, Sunnyvale, CA) further defined the ability of a robotic-assist device to address limitations in laparoscopy. This includes a significant improvement in instrument dexterity, dampening of natural hand tremors, three-dimensional visualization, ergonomics, and camera stability. As experience with robotic technology increased and its applications to advanced laparoscopic procedures have become more understood, more procedures have been performed with robotic assistance. Numerous studies have shown equivalent or improved patient outcomes when robotic-assist devices are used. Initially, robotic-assisted laparoscopic cholecystectomy was deemed safe, and now robotics has been shown to be safe in foregut procedures, including Nissen fundoplication, Heller myotomy, gastric banding procedures, and Roux-en-Y gastric bypass. These techniques have been extrapolated to solid-organ procedures (splenectomy, adrenalectomy, and pancreatic surgery) as well as robotic-assisted laparoscopic colectomy. In this chapter, we review the evolution of robotic technology and its applications in general surgical procedures.

  8. Design of Multi-core Fiber Patch Panel for Space Division Multiplexing Implementations

    DEFF Research Database (Denmark)

    Gonzalez, Luz E.; Morales, Alvaro; Rommel, Simon

    2018-01-01

    A multi-core fiber (MCF) patch panel was designed, allowing easy coupling of individual signals to and from a 7-core MCF. The device was characterized, measuring insertion loss and cross talk, finding highest insertion loss and lowest crosstalk at 1300 nm with values of 9.7 dB and -36.5 d...

  9. Design of multi-core fiber patch panel for space division multiplexing implementations

    NARCIS (Netherlands)

    González, Luz E.; Morales, Alvaro; Rommel, Simon; Jørgensen, Bo F.; Porras-Montenegro, N.; Tafur Monroy, Idelfonso

    2018-01-01

    A multi-core fiber (MCF) patch panel was designed, allowing easy coupling of individual signals to and from a 7-core MCF. The device was characterized, measuring insertion loss and cross talk, finding highest insertion loss and lowest crosstalk at 1300 nm with values of 9.7 dB and -36.5 dB

  10. Volumetry of human molars with flat panel-based volume CT in vitro

    NARCIS (Netherlands)

    Hannig, C.; Krieger, E.; Dullin, C.; Merten, H.A.; Attin, T.; Grabbe, E.; Heidrich, G.

    2006-01-01

    The flat panel-based volume computed tomography (fpVCT) is a new CT device applicable for experimental, three-dimensional evaluation of teeth at a resolution of about 150 microm in the high contrast region. The aim of this study was to investigate whether fpVCT was suitable for quantification of the

  11. Uncertainties in predicting solar panel power output

    Science.gov (United States)

    Anspaugh, B.

    1974-01-01

    The problem of calculating solar panel power output at launch and during a space mission is considered. The major sources of uncertainty and error in predicting the post launch electrical performance of the panel are considered. A general discussion of error analysis is given. Examples of uncertainty calculations are included. A general method of calculating the effect on the panel of various degrading environments is presented, with references supplied for specific methods. A technique for sizing a solar panel for a required mission power profile is developed.

  12. Orbiter radiator panel solar focusing test

    Science.gov (United States)

    Howell, H. R.; Rankin, J. G.

    1983-01-01

    Test data are presented which define the area around the Orbiter radiator panels for which the solar reflections are concentrated to one-sun or more. The concave shape of the panels and their specular silver/Teflon coating causes focusing of the reflected solar energy which could have adverse heating effects on equipment or astronaut extravehicular activity (EVA) in the vicinity of the radiator panels. A room ambient test method was utilized with a one-tenth scale model of the radiator panels.

  13. Interagency Security Classification Appeals Panel (ISCAP) Decisions

    Data.gov (United States)

    National Archives and Records Administration — This online collection includes documents decided upon by the Interagency Security Classification Appeals Panel (ISCAP) starting in Fiscal Year 2012. The documents...

  14. Development of Electrostatically Clean Solar Array Panels

    Science.gov (United States)

    Stern, Theodore G.

    2000-01-01

    Certain missions require Electrostatically Clean Solar Array (ECSA) panels to establish a favorable environment for the operation of sensitive scientific instruments. The objective of this program was to demonstrate the feasibility of an ECSA panel that minimizes panel surface potential below 100mV in LEO and GEO charged particle environments, prevents exposure of solar cell voltage and panel insulating surfaces to the ambient environment, and provides an equipotential, grounded structure surrounding the entire panel. An ECSA panel design was developed that uses a Front Side Aperture-Shield (FSA) that covers all inter-cell areas with a single graphite composite laminate, composite edge clips for connecting the FSA to the panel substrate, and built-in tabs that interconnect the FSA to conductive coated coverglasses using a conductive adhesive. Analysis indicated the ability of the design to meet the ECSA requirements. Qualification coupons and a 0.5m x 0.5m prototype panel were fabricated and tested for photovoltaic performance and electrical grounding before and after exposure to acoustic and thermal cycling environments. The results show the feasibility of achieving electrostatic cleanliness with a small penalty in mass, photovoltaic performance and cost, with a design is structurally robust and compatible with a wide range of current solar panel technologies.

  15. Microcontroller-based system for analyzing and characterizing solar panels

    International Nuclear Information System (INIS)

    Jabbar, Muhandis Abdul; Prawito

    2016-01-01

    A solar cell is one of many alternative energy which is still being developed and it works by converting sunlight into electricity. In order to use a solar cell, a deep knowledge about the solar cell’s characteristics is needed. The current and voltage (I-V) produced when the light hits the solar cell surface with a certain value of intensity and at a certain value of temperature becomes the basic study to determine solar cell characteristics. In the past decade, there were so many developments of devices to characterize solar cells and solar panels. One of them used a MOSFET device for varying electronic load to observe solar cell current and voltage responses. However, many devices which have been developed even device on the market using many expensive tools and quite complex. Therefore in this research, a simple low cost electronic controlled device for solar cell characterization is built based on MOSFET method and a microcontroller but still has high reliability and accuracy.

  16. Microcontroller-based system for analyzing and characterizing solar panels

    Energy Technology Data Exchange (ETDEWEB)

    Jabbar, Muhandis Abdul, E-mail: muhandis.abdul@sci.ui.ac.id; Prawito [System and Instrumentation, Departemen Fisika, FMIPA Universitas Indonesia, Kampus UI Depok (Indonesia)

    2016-04-19

    A solar cell is one of many alternative energy which is still being developed and it works by converting sunlight into electricity. In order to use a solar cell, a deep knowledge about the solar cell’s characteristics is needed. The current and voltage (I-V) produced when the light hits the solar cell surface with a certain value of intensity and at a certain value of temperature becomes the basic study to determine solar cell characteristics. In the past decade, there were so many developments of devices to characterize solar cells and solar panels. One of them used a MOSFET device for varying electronic load to observe solar cell current and voltage responses. However, many devices which have been developed even device on the market using many expensive tools and quite complex. Therefore in this research, a simple low cost electronic controlled device for solar cell characterization is built based on MOSFET method and a microcontroller but still has high reliability and accuracy.

  17. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... out more. Cleft Lip/Palate and Craniofacial Surgery Cleft Lip/Palate and Craniofacial Surgery A cleft lip may require ... out more. Cleft Lip/Palate and Craniofacial Surgery Cleft Lip/Palate and Craniofacial Surgery A cleft lip may require ...

  18. Mechanical testing of a FW panel attachment system for ITER

    International Nuclear Information System (INIS)

    Oliva, Vladislav; Vaclavik, Jaroslav; Materna, Ales; Lorenzetto, Patrick; Furmanek, Andreas

    2009-01-01

    An objective of experiments and finite element simulations was to check the stiffness, the strength and the fatigue resistance of the attachment of the First Wall panels onto a shield block of blanket modules according to the ITER 2001 design. The panel has a poloidal key at the rear side (in so-called option A with the rear access bolting) and it is attached by means of special studs located on a key-way in the shield block. Special device for a test of stud tensile pre-load relaxation during a thermal cycling was developed. True-to-scale panels, the shield block mock-up and simplified studs were fabricated and the assembly was loaded alternatively by radial moment, poloidal force or poloidal moment simulating the loading during off-normal plasma operations. Thermal cycling led to an acceptable stud pre-load relaxation. Mechanical cycling caused neither the pre-load relaxation nor the loss of the contact in the key-way nor a damage of the attachment system. The combination of poloidal moment and radial force during vertical displacement events (VDEs) seems to be a most dangerous case because it could lead to the loss of the key-key-way contact.

  19. Guide device

    International Nuclear Information System (INIS)

    Brammer, C.M. Jr.

    1977-01-01

    Disclosed is a fuel handling guide tube centering device for use in nuclear reactors during fuel assembly handling operations. The device comprises an outer ring secured to the flange of a nuclear reactor pressure vessel, a rotatable table rotatably coupled to the outer ring, and a plurality of openings through the table. Truncated locating cones are positioned in each of the openings in the table, and the locating cones center the guide tube during fuel handling operations. The openings in the table are located such that each fuel assembly in the nuclear core may be aligned with one of the openings by a suitable rotation of the table. The locating cones thereby provide alignment between the fuel handling mechanism located in the guide tube and the individual fuel assemblies of the cone. The need for a device to provide alignment is especially critical for floating nuclear power plants, where wave motion may exist during fuel handling operations. 5 claims, 4 figures

  20. Laser illuminated flat panel display

    Energy Technology Data Exchange (ETDEWEB)

    Veligdan, J.T.

    1995-12-31

    A 10 inch laser illuminated flat panel Planar Optic Display (POD) screen has been constructed and tested. This POD screen technology is an entirely new concept in display technology. Although the initial display is flat and made of glass, this technology lends itself to applications where a plastic display might be wrapped around the viewer. The display screen is comprised of hundreds of planar optical waveguides where each glass waveguide represents a vertical line of resolution. A black cladding layer, having a lower index of refraction, is placed between each waveguide layer. Since the cladding makes the screen surface black, the contrast is high. The prototype display is 9 inches wide by 5 inches high and approximately I inch thick. A 3 milliwatt HeNe laser is used as the illumination source and a vector scanning technique is employed.

  1. Microclimate boxes for panel paintings

    DEFF Research Database (Denmark)

    Wadum, Jørgen

    1998-01-01

    The use of microclimate boxes to protect vulnerable panel paintings is, therefore, not a new phenomenon of the past two or three decades. Rather, it has been a concern for conservators and curators to protect these objects of art at home and in transit since the end of the nineteenth century....... The increased number of travelling exhibitions in recent years has heightened the need to protect paintings during circulation (Thomson 1961; Mecklenburg 1991). The use and design of microclimate boxes have been evolving since 1892. These boxes may be divided into three broad groups: those using an active...... buffer material to stabilize the internal RH, a more recent box containing no added buffer material, and, in recent times, boxes with an altered gas content. Another concern is the appearance (aesthetics) of the box....

  2. AQUEOUS HOMOGENEOUS REACTORTECHNICAL PANEL REPORT

    Energy Technology Data Exchange (ETDEWEB)

    Diamond, D.J.; Bajorek, S.; Bakel, A.; Flanagan, G.; Mubayi, V.; Skarda, R.; Staudenmeier, J.; Taiwo, T.; Tonoike, K.; Tripp, C.; Wei, T.; Yarsky, P.

    2010-12-03

    Considerable interest has been expressed for developing a stable U.S. production capacity for medical isotopes and particularly for molybdenum- 99 (99Mo). This is motivated by recent re-ductions in production and supply worldwide. Consistent with U.S. nonproliferation objectives, any new production capability should not use highly enriched uranium fuel or targets. Conse-quently, Aqueous Homogeneous Reactors (AHRs) are under consideration for potential 99Mo production using low-enriched uranium. Although the Nuclear Regulatory Commission (NRC) has guidance to facilitate the licensing process for non-power reactors, that guidance is focused on reactors with fixed, solid fuel and hence, not applicable to an AHR. A panel was convened to study the technical issues associated with normal operation and potential transients and accidents of an AHR that might be designed for isotope production. The panel has produced the requisite AHR licensing guidance for three chapters that exist now for non-power reactor licensing: Reac-tor Description, Reactor Coolant Systems, and Accident Analysis. The guidance is in two parts for each chapter: 1) standard format and content a licensee would use and 2) the standard review plan the NRC staff would use. This guidance takes into account the unique features of an AHR such as the fuel being in solution; the fission product barriers being the vessel and attached systems; the production and release of radiolytic and fission product gases and their impact on operations and their control by a gas management system; and the movement of fuel into and out of the reactor vessel.

  3. Fixture for assembling solar panels

    Science.gov (United States)

    Dillard, P. A.; Fritz, W. M.

    1979-01-01

    Vacuum fixture attaches array of silicon solar cells to mounting plate made of clear glass which holds and protects cells. Glass plate transmits, rather than absorbs, solar energy thus cooling cells for efficient operation. Device therefore reduces handling of cells and interconnecting conductors to one operation.

  4. Medical Devices

    NARCIS (Netherlands)

    Verkerke, Gijsbertus Jacob; Mahieu, H.F.; Geertsema, A.A.; Hermann, I.F.; van Horn, J.R.; Hummel, J. Marjan; van Loon, J.P.; Mihaylov, D.; van der Plaats, A.; Schraffordt Koops, H.; Schutte, H.K.; Veth, R.P.H.; de Vries, M.P.; Rakhorst, G.; Shi, Donglu

    2004-01-01

    The development of new medical devices is a very time-consuming and costly process. Besides the time between the initial idea and the time that manufacturing and testing of prototypes takes place, the time needed for the development of production facilities, production of test series, marketing,

  5. Electrochemical device

    Science.gov (United States)

    Grimes, Patrick G.; Einstein, Harry; Bellows, Richard J.

    1988-01-12

    A tunnel protected electrochemical device features channels fluidically communicating between manifold, tunnels and cells. The channels are designed to provide the most efficient use of auxiliary power. The channels have a greater hydraulic pressure drop and electrical resistance than the manifold. This will provide a design with the optimum auxiliary energy requirements.

  6. Assistive Devices

    Science.gov (United States)

    If you have a disability or injury, you may use a number of assistive devices. These are tools, products or types of equipment that help you perform tasks and activities. They may help you move around, see, communicate, eat, or get ...

  7. Detection device

    Science.gov (United States)

    Smith, J.E.

    1981-02-27

    The present invention is directed to a detection device comprising: (1) an entrance chamber; (2) a central chamber; and (3) an exit chamber. The central chamber includes an ionizing gas, anode, and means for connecting the anode with an external power supply and pulse counter.

  8. Cooling device in thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Tsutomu.

    1988-01-01

    Purpose: To prevent loss of cooling effect over the entire torus structure directly after accidental toubles in a cooling device of a thermonuclear device. Constitution: Coolant recycling means of a cooling device comprises two systems, which are alternately connected with in-flow pipeways and exit pipeways of adjacent modules. The modules are cooled by way of the in-flow pipeways and the exist pipeways connected to the respective modules by means of the coolant recycling means corresponding to the respective modules. So long as one of the coolant recycling means is kept operative, since every one other modules of the torus structure is still kept cooled, the heat generated from the module put therebetween, for which the coolant recycling is interrupted, is removed by means of heat conduction or radiation from the module for which the cooling is kept continued. No back-up emergency cooling system is required and it can provide high economic reliability. (Kamimura, M.)

  9. Touch panel system for control applications

    International Nuclear Information System (INIS)

    Crook, K.; Johnson, R.

    1976-12-01

    The use of finger-sensitive touch panels in association with computer-generated displays for control and monitoring of the Stanford linear accelerator is discussed. This control concept has proven to be very effective. The hardware and software aspects of the Touch Panel portion of the control system are described

  10. Electronic unit for fotovoltaic solar panelling validation

    International Nuclear Information System (INIS)

    Vazquez, J.; Valverde, J.; Garcia, J.M.

    1988-01-01

    A low cost and easy to use electronic system for photovoltaic solar panelling validation is described. It measures, with a certain periodicity, voltage and current given by the panel, determines the supplied power, and every so often, its maximum valves. The unit is fitted with a data storage system which allows data recording for later analysis. (Author)

  11. Outgassing tests on iras solar panel samples

    Science.gov (United States)

    Premat, G.; Zwaal, A.; Pennings, N. H.

    1980-01-01

    Several outgassing tests were carried out on representative solar panel samples in order to determine the extent of contamination that could be expected from this source. The materials for the construction of the solar panels were selected as a result of contamination obtained in micro volatile condensable materials tests.

  12. 49 CFR 845.22 - Technical panel.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Technical panel. 845.22 Section 845.22... Technical panel. The Director, Bureau of Accident Investigation, or the Director, Bureau of Field Operations, shall designate members of the Board's technical staff to participate in the hearing and initially...

  13. Dynamic spatial panels : models, methods, and inferences

    NARCIS (Netherlands)

    Elhorst, J. Paul

    This paper provides a survey of the existing literature on the specification and estimation of dynamic spatial panel data models, a collection of models for spatial panels extended to include one or more of the following variables and/or error terms: a dependent variable lagged in time, a dependent

  14. 78 FR 74174 - Humanities Panel Advisory Committee

    Science.gov (United States)

    2013-12-10

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Humanities Panel Advisory Committee AGENCY: National Endowment for the Humanities. ACTION: Notice of Charter Renewal for Humanities Panel Advisory... its implementing regulations, 41 CFR 102-3.65, the National Endowment for the Humanities (NEH) gives...

  15. 76 FR 6828 - Meetings of Humanities Panel

    Science.gov (United States)

    2011-02-08

    ... THE NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Meetings of Humanities Panel AGENCY: The National Endowment for the Humanities. ACTION: Notice of Meetings. SUMMARY: Pursuant to the provisions of... following meetings of Humanities Panels will be held at the Old Post Office, 1100 Pennsylvania Avenue, NW...

  16. 75 FR 18906 - Meetings of Humanities Panel

    Science.gov (United States)

    2010-04-13

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Meetings of Humanities Panel AGENCY: The National Endowment for the Humanities. ACTION: Notice of Meetings. SUMMARY: Pursuant to the provisions of... following meetings of Humanities Panels will be held at the Old Post Office, 1100 Pennsylvania Avenue, NW...

  17. 76 FR 14434 - Meetings of Humanities Panel

    Science.gov (United States)

    2011-03-16

    ... THE NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Meetings of Humanities Panel AGENCY: The National Endowment for the Humanities, National Foundation on the Arts and the Humanities. ACTION: Notice...-463, as amended), notice is hereby given that the following meetings of Humanities Panels will be held...

  18. 75 FR 50007 - Meetings of Humanities Panel

    Science.gov (United States)

    2010-08-16

    ... THE NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Meetings of Humanities Panel AGENCY: The National Endowment for the Humanities. ACTION: Notice of Meetings. SUMMARY: Pursuant to the provisions of... following meetings of Humanities Panels will be held at the Old Post Office, 1100 Pennsylvania Avenue, NW...

  19. 75 FR 26285 - Meetings of Humanities Panel

    Science.gov (United States)

    2010-05-11

    ... THE NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Meetings of Humanities Panel AGENCY: The National Endowment for the Humanities. ACTION: Notice of meetings. SUMMARY: Pursuant to the provisions of... following meetings of Humanities Panels will be held at the Old Post Office, 1100 Pennsylvania Avenue, NW...

  20. 76 FR 77559 - Meeting of Humanities Panel

    Science.gov (United States)

    2011-12-13

    ... THE NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Meeting of Humanities Panel AGENCY: The National Endowment for the Humanities. ACTION: Notice of Meeting. SUMMARY: Pursuant to the provisions of... of the Humanities Panel will be held at the Old Post Office, 1100 Pennsylvania Avenue NW., Washington...

  1. 77 FR 22359 - Meetings of Humanities Panel

    Science.gov (United States)

    2012-04-13

    ... THE NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Meetings of Humanities Panel AGENCY: The National Endowment for the Humanities. ACTION: Notice of Meetings. SUMMARY: Pursuant to the provisions of... following meetings of Humanities Panels will be held at the Old Post Office, 1100 Pennsylvania Avenue NW...

  2. 76 FR 20375 - Meetings of Humanities Panel

    Science.gov (United States)

    2011-04-12

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Meetings of Humanities Panel AGENCY: The National Endowment for the Humanities ACTION: Notice of additional meeting. SUMMARY: Pursuant to the... the following meeting of the Humanities Panel will be held at the Old Post Office, 1100 Pennsylvania...

  3. 76 FR 70168 - Meetings of Humanities Panel

    Science.gov (United States)

    2011-11-10

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Meetings of Humanities Panel AGENCY: The National Endowment for the Humanities. ACTION: Notice of additional meeting. SUMMARY: Pursuant to the... the following meeting of the Humanities Panel will be held at the Old Post Office, 1100 Pennsylvania...

  4. 76 FR 41826 - Meetings of Humanities Panel

    Science.gov (United States)

    2011-07-15

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Meetings of Humanities Panel AGENCY: The National Endowment for the Humanities. ACTION: Notice of additional meeting. SUMMARY: Pursuant to the... the following meeting of the Humanities Panel will be held at the Old Post Office, 1100 Pennsylvania...

  5. 76 FR 52697 - Meetings of Humanities Panel

    Science.gov (United States)

    2011-08-23

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Meetings of Humanities Panel AGENCY: The National Endowment for the Humanities. ACTION: Notice of meetings. SUMMARY: Pursuant to the provisions of... following meetings of Humanities Panels will be held at the Old Post Office, 1100 Pennsylvania Avenue, NW...

  6. 76 FR 56242 - Meetings of Humanities Panel

    Science.gov (United States)

    2011-09-12

    ... THE NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Meetings of Humanities Panel AGENCY: The National Endowment for the Humanities, The National Foundation on the Arts and the Humanities. ACTION... Humanities Panel at the Old Post Office, 1100 Pennsylvania Avenue, NW., Washington, DC 20506 which was...

  7. 76 FR 70765 - Meetings of Humanities Panel

    Science.gov (United States)

    2011-11-15

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Meetings of Humanities Panel AGENCY: The National Endowment for the Humanities, National Foundation on the Arts and the Humanities. ACTION: Notice...-463, as amended), notice is hereby given that the following meetings of Humanities Panels will be held...

  8. 76 FR 63664 - Meetings of Humanities Panel

    Science.gov (United States)

    2011-10-13

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Meetings of Humanities Panel AGENCY: The National Endowment for the Humanities. ACTION: Notice of meetings. SUMMARY: Pursuant to the provisions of... following meetings of Humanities Panels will be held at the Old Post Office, 1100 Pennsylvania Avenue, NW...

  9. 77 FR 17102 - Meetings of Humanities Panel

    Science.gov (United States)

    2012-03-23

    ... THE NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Meetings of Humanities Panel AGENCY: The National Endowment for the Humanities, National Foundation on the Arts and the Humanities ACTION... Humanities Panel at the Old Post Office, 1100 Pennsylvania Avenue NW., Washington, DC 20506, which was...

  10. An intersection test for panel unit roots

    NARCIS (Netherlands)

    Hanck, C.

    2013-01-01

    This article proposes a new panel unit root test based on Simes' ( 1986) classical intersection test. The test is robust to general patterns of cross-sectional dependence and yet is straightforward to implement, only requiring p-values of time series unit root tests of the series in the panel, and

  11. Blood Test: Comprehensive Metabolic Panel (CMP)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Blood Test: Comprehensive Metabolic Panel (CMP) KidsHealth / For Parents / Blood ... de sangre: panel metabólico ampliado What Is a Blood Test? A blood test is when a sample of ...

  12. Documentation Panels Enhance Teacher Education Programs

    Science.gov (United States)

    Warash, Bobbie Gibson

    2005-01-01

    Documentation of children's projects is advantageous to their learning process and is also a good method for student teachers to observe the process of learning. Documentation panels are a unique way to help student teachers understand how children learn. Completing a panel requires a student teacher to think through a process. Teachers must learn…

  13. Delamination tolerance studies in laminated composite panels

    Indian Academy of Sciences (India)

    Abstract. Determination of levels of tolerance in delaminated composite panels is an important issue in composite structures technology. The primary intention is to analyse delaminated composite panels and estimate Strain. Energy Release Rate (SERR) parameters at the delamination front to feed into acceptability criteria.

  14. Response problems in a vacation panel study

    Science.gov (United States)

    Christine A. Vogt; Susan I. Stewart

    2001-01-01

    This paper investigates response problems encountered in a panel study of travel behavior. Though the overall response rate to the three-wave panel study was acceptable (over 60%), three types of response problems were encountered: refusal, non-response, and attrition. In a follow-up phone survey, a sample of individuals from each problem response group was questioned...

  15. 78 FR 42982 - Arts Advisory Panel Meeting

    Science.gov (United States)

    2013-07-18

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts Advisory Panel Meeting AGENCY: National Endowment for the Arts, National Foundation on the Arts and Humanities. ACTION: Notice of Meetings SUMMARY... hereby given one meeting of the Arts Advisory Panel to the National Council on the Arts will be held at...

  16. 77 FR 61643 - Arts Advisory Panel Meeting

    Science.gov (United States)

    2012-10-10

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts Advisory Panel Meeting AGENCY: National Endowment for the Arts, National Foundation on the Arts and Humanities. ACTION: Notice of meeting. SUMMARY... hereby given that sixteen meetings of the Arts Advisory Panel to the National Council on the Arts will be...

  17. 78 FR 17942 - Arts Advisory Panel Meeting

    Science.gov (United States)

    2013-03-25

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts Advisory Panel Meeting AGENCY: National Endowment for the Arts, National Foundation on the Arts and Humanities. ACTION: Notice of meetings. SUMMARY... hereby given that five meetings of the Arts Advisory Panel to the National Council on the Arts will be...

  18. 78 FR 59978 - Arts Advisory Panel Meeting

    Science.gov (United States)

    2013-09-30

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts Advisory Panel Meeting AGENCY: National Endowment for the Arts, National Foundation on the Arts and Humanities. ACTION: Notice of meeting. SUMMARY... hereby given that one meeting of the Arts Advisory Panel to the National Council on the Arts will be held...

  19. 77 FR 49026 - Arts Advisory Panel Meeting

    Science.gov (United States)

    2012-08-15

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts Advisory Panel Meeting AGENCY: National Endowment for the Arts, National Foundation on the Arts and Humanities. ACTION: Notice of meeting. SUMMARY... hereby given that one meeting of the Arts Advisory Panel to the National Council on the Arts will be held...

  20. 78 FR 21978 - Arts Advisory Panel Meeting

    Science.gov (United States)

    2013-04-12

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts Advisory Panel Meeting AGENCY: National Endowment for the Arts, National Foundation on the Arts and Humanities. ACTION: Notice of meeting. SUMMARY... is hereby given that one meeting of the Arts Advisory Panel to the National Council on the Arts will...

  1. 78 FR 26399 - Arts Advisory Panel Meeting

    Science.gov (United States)

    2013-05-06

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts Advisory Panel Meeting AGENCY: National Endowment for the Arts, National Foundation on the Arts and Humanities. ACTION: Notice of Meeting. SUMMARY... hereby given that one meeting of the Arts Advisory Panel to the National Council on the Arts will be held...

  2. 77 FR 13154 - Arts Advisory Panel Meeting

    Science.gov (United States)

    2012-03-05

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts Advisory Panel Meeting AGENCY: National Endowment for the Arts, National Foundation on the Arts and Humanities. ACTION: Notice--meeting. Pursuant to... given that a meeting of the Arts Advisory Panel to the National Council on the Arts will be held by...

  3. 77 FR 67836 - Arts Advisory Panel Meeting

    Science.gov (United States)

    2012-11-14

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts Advisory Panel Meeting AGENCY: National Endowment for the Arts, National Foundation on the Arts and Humanities. ACTION: Notice of Meeting. SUMMARY... hereby given that fifteen meetings of the Arts Advisory Panel to the National Council on the Arts will be...

  4. 78 FR 5213 - Arts Advisory Panel Meeting

    Science.gov (United States)

    2013-01-24

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts Advisory Panel Meeting AGENCY: National Endowment for the Arts, National Foundation on the Arts and Humanities. ACTION: Notice of meeting. SUMMARY... hereby given that one meeting of the Arts Advisory Panel to the National Council on the Arts will be held...

  5. 77 FR 75672 - Arts Advisory Panel Meeting

    Science.gov (United States)

    2012-12-21

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts Advisory Panel Meeting AGENCY: National Endowment for the Arts, National Foundation on the Arts and Humanities. ACTION: Notice of Meeting. SUMMARY... hereby given that seven meetings of the Arts Advisory Panel to the National Council on the Arts will be...

  6. 77 FR 41808 - Arts Advisory Panel Meeting

    Science.gov (United States)

    2012-07-16

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts Advisory Panel Meeting AGENCY: National Endowment for the Arts, National Foundation on the Arts and Humanities. ACTION: Notice of meeting. SUMMARY... hereby given that two meetings of the Arts Advisory Panel to the National Council on the Arts will be...

  7. 78 FR 68099 - Arts Advisory Panel Meeting

    Science.gov (United States)

    2013-11-13

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts Advisory Panel Meeting AGENCY: National Endowment for the Arts, National Foundation on the Arts and Humanities. ACTION: Notice of Meeting. SUMMARY... hereby given that twenty- one meetings of the Arts Advisory Panel to the National Council on the Arts...

  8. 78 FR 50451 - Arts Advisory Panel Meeting

    Science.gov (United States)

    2013-08-19

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts Advisory Panel Meeting AGENCY: National Endowment for the Arts, National Foundation on the Arts and Humanities. ACTION: Notice of Meetings. SUMMARY... hereby given that one meeting of the Arts Advisory Panel to the National Council on the Arts will be held...

  9. 77 FR 56875 - Arts Advisory Panel Meeting

    Science.gov (United States)

    2012-09-14

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts Advisory Panel Meeting AGENCY: National Endowment for the Arts, National Foundation on the Arts and Humanities. ACTION: Notice of meeting. SUMMARY... hereby given that two meetings of the Arts Advisory Panel to the National Council on the Arts will be...

  10. 77 FR 13367 - Arts Advisory Panel Meeting

    Science.gov (United States)

    2012-03-06

    ... NATIONAL FOUNDATION ON THE ARTS AND THE HUMANITIES Arts Advisory Panel Meeting AGENCY: National Endowment for the Arts, National Foundation on the Arts and Humanities. ACTION: Notice of meeting. SUMMARY... hereby given that a meeting of the Arts Advisory Panel to the National Council on the Arts will be held...

  11. Research challenges for energy data management (panel)

    DEFF Research Database (Denmark)

    Pedersen, Torben Bach; Lehner, Wolfgang

    2013-01-01

    This panel paper aims at initiating discussion at the Second International Workshop on Energy Data Management (EnDM 2013) about the important research challenges within Energy Data Management. The authors are the panel organizers, extra panelists will be recruited before the workshop...

  12. Robust block bootstrap panel predictability tests

    NARCIS (Netherlands)

    Westerlund, J.; Smeekes, S.

    2013-01-01

    Most panel data studies of the predictability of returns presume that the cross-sectional units are independent, an assumption that is not realistic. As a response to this, the current paper develops block bootstrap-based panel predictability tests that are valid under very general conditions. Some

  13. Air loads on solar panels during launch

    NARCIS (Netherlands)

    Beltman, W.M.; van der Hoogt, Peter; Spiering, R.M.E.J.; Tijdeman, H.

    1996-01-01

    The dynamical behaviour of solar panels during launch is significantly affected by the thin layers of air trapped between the panels. For narrow gaps the air manifests itself not only as a considerable added mass, but its viscosity can result in a substantial amount of damping. A model has been

  14. Establishment of a large panel of patient-derived preclinical models of human renal cell carcinoma

    OpenAIRE

    Lang, Herv?; B?raud, Claire; Bethry, Audrey; Danilin, Sabrina; Lindner, V?ronique; Coquard, Catherine; Rothhut, Sylvie; Massfelder, Thierry

    2016-01-01

    The objective of the present work was to establish a large panel of preclinical models of human renal cell carcinoma (RCC) directly from patients, faithfully reproducing the biological features of the original tumor. RCC tissues (all stages/subtypes) were collected for 8 years from 336 patients undergoing surgery, xenografted subcutaneously in nude mice, and serially passaged into new mice up to 13 passages. Tissue samples from the primary tumor and tumors grown in mice through passages were ...

  15. Differing professional opinions: 1987 special review panel

    International Nuclear Information System (INIS)

    1988-01-01

    In November 1987, the five-member Differing Professional Opinions Special Review Panel established by the Executive Director for Operations of the US Nuclear Regulatory Commission to review agency policies and procedures for handling differing professional opinions (DPOs) presented its findings and recommendations in NUREG-1290. The issuance of that report completed the first task of the panel's charter. In accordance with Manual chapter 4125, Section L, and the charter of the Special Review Panel, the panel's second task was to ''...review...the DPOs submitted subsequent to the previous Panel's review, in order to identify any employee whose DPO made a significant contribution to the Agency or to the public safety but who has not yet been recognized for such contribution.'' This Addendum provides the findings of that review

  16. Graphite/epoxy orthogrid panel fabrication

    Science.gov (United States)

    Lager, J. R.

    1978-01-01

    The structural concept considered for a spacecraft body structure is a grid stiffened skin with a skin laminate configuration and the stiffener grid geometry selected to best suit the design requirements. The orthogrid panel developed weighs 0.55 lb/sq ft and resisted an ultimate in-plane shear load of 545 lbf/in. The basic concept of a grid stiffener composite panel is that a relatively thin skin is reinforced with a gridwork of stiffeners so that the overall panel can resist design loads without becoming structurally unstable or being overstressed. The main feature of the orthogrid panel design is that it provides the potential for low cost structural panels when advanced to the production phase. The most innovative part of the fabrication method is the foam/fiberglass stiffener web grid billet fabrication and machining to size.

  17. The Atomic Safety and Licensing Board Panel

    International Nuclear Information System (INIS)

    1998-01-01

    Through the Atomic Energy Act, Congress made is possible for the public to get a full and fair hearing on civilian nuclear matters. Individuals who are directly affected by any licensing action involving a facility producing or utilizing nuclear materials may participate in a formal hearing, on the record, before independent judges on the Atomic Safety and Licensing Board Panel (ASLBP or Panel). Frequently, in deciding whether a license, permit, amendment, or extension should be granted to a particular applicant, the Panel members must be more than mere umpires. If appropriate, they are authorized to go beyond the issues the parties place before them in order to identify, explore, and resolve significant questions involving threats to the public health and safety that come to a board's attention during the proceedings. This brochure explains the purpose of the panel. Also addressed are: type of hearing handled; method of public participation; formality of hearings; high-level waste; other panel responsibilities and litigation technology

  18. Thin film photovoltaic panel and method

    Science.gov (United States)

    Ackerman, Bruce; Albright, Scot P.; Jordan, John F.

    1991-06-11

    A thin film photovoltaic panel includes a backcap for protecting the active components of the photovoltaic cells from adverse environmental elements. A spacing between the backcap and a top electrode layer is preferably filled with a desiccant to further reduce water vapor contamination of the environment surrounding the photovoltaic cells. The contamination of the spacing between the backcap and the cells may be further reduced by passing a selected gas through the spacing subsequent to sealing the backcap to the base of the photovoltaic panels, and once purged this spacing may be filled with an inert gas. The techniques of the present invention are preferably applied to thin film photovoltaic panels each formed from a plurality of photovoltaic cells arranged on a vitreous substrate. The stability of photovoltaic conversion efficiency remains relatively high during the life of the photovoltaic panel, and the cost of manufacturing highly efficient panels with such improved stability is significantly reduced.

  19. Report of the Federal Internetworking Requirements Panel

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-05-31

    The Federal Internetworking Requirements Panel (FIRP) was established by the National Institute of Standards and Technology (NIST) to reassess Federal requirements for open systems networks and to recommend policy on the Government`s use of networking standards. The Panel was chartered to recommend actions which the Federal Government can take to address the short and long-term issues of interworking and convergence of networking protocols--particularly the Internet Protocol Suite (IPS) and Open Systems Interconnection (OSI) protocol suite and, when appropriate, proprietary protocols. The Panel was created at the request of the Office of Management and Budget in collaboration with the Federal Networking Council and the Federal Information Resources Management Policy Council. The Panel`s membership and charter are contained in an appendix to this report.

  20. Photoelectric panel with equatorial mounting of drive

    Science.gov (United States)

    Kukhta, M. S.; Krauinsh, P. Y.; Krauinsh, D. P.; Sokolov, A. P.; Mainy, S. B.

    2018-03-01

    The relevance of the work is determined by the need to create effective models for sunny energy. The article considers a photoelectric panel equipped with a system for tracking the sun. Efficiency of the system is provided by equatorial mounting, which compensates for the rotation of the Earth by rotating the sunny panel in the plane of the celestial equator. The specificity of climatic and geographical conditions of Tomsk is estimated. The dynamics of power variations of photoelectric panels with equatorial mounting during seasonal fluctuations in Tomsk is calculated. A mobile photovoltaic panel with equatorial mounting of the drive has been developed. The methods of design strategy for placing photovoltaic panels in the architectural environment of the city are presented. Key words: sunny energy, photovoltaics, equatorial mounting, mechatronic model, wave reducer, electric drive.

  1. Gene panel testing for inherited cancer risk.

    Science.gov (United States)

    Hall, Michael J; Forman, Andrea D; Pilarski, Robert; Wiesner, Georgia; Giri, Veda N

    2014-09-01

    Next-generation sequencing technologies have ushered in the capability to assess multiple genes in parallel for genetic alterations that may contribute to inherited risk for cancers in families. Thus, gene panel testing is now an option in the setting of genetic counseling and testing for cancer risk. This article describes the many gene panel testing options clinically available to assess inherited cancer susceptibility, the potential advantages and challenges associated with various types of panels, clinical scenarios in which gene panels may be particularly useful in cancer risk assessment, and testing and counseling considerations. Given the potential issues for patients and their families, gene panel testing for inherited cancer risk is recommended to be offered in conjunction or consultation with an experienced cancer genetic specialist, such as a certified genetic counselor or geneticist, as an integral part of the testing process. Copyright © 2014 by the National Comprehensive Cancer Network.

  2. Panel fabrication utilizing GaAs solar cells

    Science.gov (United States)

    Mardesich, N.

    1984-01-01

    The development of the GaAs solar cells for space applications is described. The activities in the fabrication of GaAs solar panels are outlined. Panels were fabricated while introducing improved quality control, soldering laydown and testing procedures. These panels include LIPS II, San Marco Satellite, and a low concentration panel for Rockwells' evaluation. The panels and their present status are discussed.

  3. Noise Reduction in Double‿Panel Structures by Cavity and Panel Resonance Control

    OpenAIRE

    Ho, J.; Berkhoff, Arthur P.

    2011-01-01

    This paper presents an investigation of the cavity and the panel resonance control in a double‿panel structure. The double‿panel structure, which consists of two panels with air in the gap, is widely adopted in many applications such as aerospace due to its light weight and effective transmission‿loss at high frequency. However, the resonance of the cavity and the poor transmission‿loss at low frequency limit its noise control performance. Applying active control forces on the panels or utili...

  4. Acoustically Tailored Composite Rotorcraft Fuselage Panels

    Science.gov (United States)

    Hambric, Stephen; Shepherd, Micah; Koudela, Kevin; Wess, Denis; Snider, Royce; May, Carl; Kendrick, Phil; Lee, Edward; Cai, Liang-Wu

    2015-01-01

    A rotorcraft roof sandwich panel has been redesigned to optimize sound power transmission loss (TL) and minimize structure-borne sound for frequencies between 1 and 4 kHz where gear meshing noise from the transmission has the most impact on speech intelligibility. The roof section, framed by a grid of ribs, was originally constructed of a single honeycomb core/composite face sheet panel. The original panel has coincidence frequencies near 700 Hz, leading to poor TL across the frequency range of 1 to 4 kHz. To quiet the panel, the cross section was split into two thinner sandwich subpanels separated by an air gap. The air gap was sized to target the fundamental mass-spring-mass resonance of the double panel system to less than 500 Hz. The panels were designed to withstand structural loading from normal rotorcraft operation, as well as 'man-on-the-roof' static loads experienced during maintenance operations. Thin layers of VHB 9469 viscoelastomer from 3M were also included in the face sheet ply layups, increasing panel damping loss factors from about 0.01 to 0.05. Measurements in the NASA SALT facility show the optimized panel provides 6-11 dB of acoustic transmission loss improvement, and 6-15 dB of structure-borne sound reduction at critical rotorcraft transmission tonal frequencies. Analytic panel TL theory simulates the measured performance quite well. Detailed finite element/boundary element modeling of the baseline panel simulates TL slightly more accurately, and also simulates structure-borne sound well.

  5. Graphite Composite Panel Polishing Fixture

    Science.gov (United States)

    Hagopian, John; Strojny, Carl; Budinoff, Jason

    2011-01-01

    The use of high-strength, lightweight composites for the fixture is the novel feature of this innovation. The main advantage is the light weight and high stiffness-to-mass ratio relative to aluminum. Meter-class optics require support during the grinding/polishing process with large tools. The use of aluminum as a polishing fixture is standard, with pitch providing a compliant layer to allow support without deformation. Unfortunately, with meter-scale optics, a meter-scale fixture weighs over 120 lb (.55 kg) and may distort the optics being fabricated by loading the mirror and/or tool used in fabrication. The use of composite structures that are lightweight yet stiff allows standard techniques to be used while providing for a decrease in fixture weight by almost 70 percent. Mounts classically used to support large mirrors during fabrication are especially heavy and difficult to handle. The mount must be especially stiff to avoid deformation during the optical fabrication process, where a very large and heavy lap often can distort the mount and optic being fabricated. If the optic is placed on top of the lapping tool, the weight of the optic and the fixture can distort the lap. Fixtures to support the mirror during fabrication are often very large plates of aluminum, often 2 in. (.5 cm) or more in thickness and weight upwards of 150 lb (68 kg). With the addition of a backing material such as pitch and the mirror itself, the assembly can often weigh over 250 lb (.113 kg) for a meter-class optic. This innovation is the use of a lightweight graphite panel with an aluminum honeycomb core for use as the polishing fixture. These materials have been used in the aerospace industry as structural members due to their light weight and high stiffness. The grinding polishing fixture consists of the graphite composite panel, fittings, and fixtures to allow interface to the polishing machine, and introduction of pitch buttons to support the optic under fabrication. In its

  6. Thermonuclear device

    International Nuclear Information System (INIS)

    Oosaki, Osamu; Masuda, Kenju.

    1980-01-01

    Purpose: To provide excellent electric properties and high reliability in a thermonuclear device by improving a current collecting board connected to a coil device. Constitution: A current collecting board element perforated with an opening for enserting a connecting terminal is sized to be inserted into a plating tank, and is surface treated in the plating tank. Only the current collecting board element preferably surface treated is picked up. A plurality of such current collecting board elements are connected and welded to form a large current collecting board. In this manner, the current collecting board having several m 2 to several ten order m 2 in area can be obtained as preferably surface treated at the connecting terminal hole. The current collecting board element can be determined in shape with the existing facility without increasing the size of a surface treating tank. (Kamimura, M.)

  7. Thermonuclear device

    International Nuclear Information System (INIS)

    Yagi, Yasuomi; Takahashi, Ken; Hashimoto, Hiroshi.

    1984-01-01

    Purpose: To improve the plasma confining performances by bringing the irregular magnetic fields nearly to zero and decreasing the absolute value of the irregular magnetic fields at every positions. Constitution: The winding direction of a plurality of coil elements, for instance, double pan cake coils of toroidal coils in a torus type or mirror type thermonuclear device are reversed to each other in their laminating direction, whereby the irregular magnetic fields due to the coil-stepped portions in each toroidal coils are brought nearly to zero. This enables to bring the average irregular magnetic fields as a whole in the thermonuclear device nearly to zero, as well as, decrease the absolute value of the irregular magnetic fields in each positions. Thus, the plasma confining performances can be improved. (Moriyama, K.)

  8. The Tear Osmolarity Changes After Cataract Surgery

    Directory of Open Access Journals (Sweden)

    Banu Öncel

    2012-01-01

    Full Text Available Pur po se: To determine the tear osmolarity changes in patients who had undergone phacoemulsification surgery. Ma te ri al and Met hod: Tear osmolarity measurements were performed in 30 eyes of 30 patients who had undergone cataract surgery without any complication. Measurements were performed before surgery and consecutively at 1st month, 3rd month, and 6th month after the surgery. TearLab osmometer (TearLab Corporation, San Diego, CA, USA device was used for the measurements and paired ttest was used for statistical analysis. Re sults: The mean age of the patients was 72.3±3.7 (67-78 years. Thirteen patients were men and 17 patients were women. The mean osmolarity values were 305.8±6.5 mOsm/L before the surgery and 312.3±6.4 mOsm/L at 1st month, 307.5±5.1 mOsm/L at 3rd month and 305.1±5.7 at 6th month after the surgery. The difference between the values before surgery and at 1st month was found statistically significant (p=0.001. Dis cus si on: The tear osmolarity increases at the first month after surgery but decreases to the levels measured before surgery at the 3rd month. The increase at the first month may be due to the corneal incisions and medication used after the surgery. We think that we have to take into account this similarity increase in all cataract patients, especially in those who also have dry eye disease. (Turk J Ophthalmol 2012; 42: 35-7

  9. "Distinvar" device

    CERN Multimedia

    CERN PhotoLab

    1965-01-01

    The alignment of one of the accelerator magnets being checked by the AR Division survey group. A "distinvar" device, invented by the group, using calibrated invar wires stretched between the fixed survey pillar (on the left) and a fixed point on the magnet. In two days it is thus possible to measure the alignment of the 100 magnets with an accuracy better than 1/10.

  10. Latching device

    Science.gov (United States)

    Ulrich, G. W. (Inventor)

    1975-01-01

    A latching device is suited for use in establishing a substantially motionless connection between a stationary receiver and a movable latching mechanism. The latching mechanism includes a pivotally supported restraining hook continuously urged into a capturing relationship with the receiver, characterized by a spring-biased pawl having a plurality of aligned teeth. The teeth are seated in the surface of the throat of the hook and positionable into restraining engagement with a rigid restraining shoulder projected from the receiver.

  11. Control system of fuel transporting device

    International Nuclear Information System (INIS)

    Yokota, Minoru.

    1981-01-01

    Purpose: To effectively avoid an obstacle in a fuel transporting device by reading the outputs of absolute position detectors mounted on movable trucks, controlling the movements of the trucks, and thereby smoothly and accurately positioning the fuel transporting device at predetermined position and providing a contact detector thereat. Method: The outputs from absolute position detectors which are mounted on a longitudinally movable truck and a laterally movable truck are input to an input/output control circuit. The input/output control circuit serves to compare, the position a fuel transporting device is to be moved to, with the present position on the basis of said input detection signal and a command signal from an operator console, to calculate the amount of movement to be driven, to produce an operation signal therefor to a control panel, and to drive and control the drive motors which are respectively mounted on the trucks for the fuel transfer device. On the other hand, in case that the transfer device comes into contact with an obstacle, the contact detector will immediately operate to produce a stop command through the control panel to the transporting device, and avoid a collision with the obstacle. (Yoshino, Y.)

  12. PERBANDINGAN UNJUK KERJA ANTARA PANEL SEL SURYA BERPENJEJAK DENGAN PANEL SEL SURYA DIAM

    Directory of Open Access Journals (Sweden)

    Syafaruddin Ch

    2010-07-01

    Full Text Available The ability to produce electrical energy at Solar Power Plant  is highly dependent on the magnitude and duration of sun exposure on the solar cell panels. The movement of the sun from east to west that periodicity in every day is a problem at  the  optimization generation of electricity at  Solar Power Plant   if using solar panel that motionless. This is because the solar cell panel can not catch the maximum sun exposure. To solve the above problem then designed a solar cell panel  tracker  capable of follo-wing the movements of the sun. Then conducted a test to see the performance of solar cell pa-nel  tracker  and compare it with the performance of solar cell panel was motionless. The testing doing along 6 days, with way to irradiate the panel of solar cells  tracker  and panels of solar cell motionless with sun exposure  along a  full day. Then the electric current generated each panel were recorded. The comparison of current then generating comparison of electric power delivery. The result show that the solar cell panel  tracker  produce the average current is 2.19 A whereas solar-cell panel still 1.97 A.  This result   indicate that average power for solar cell panel  tracker  39.41 W while for solar cell panel that motionless is  35.46 W. These results indicate that the performance of solar cell panel  tracker  better than  solar cell panel motionless.

  13. Devices and Endoscopic Bariatric Therapies for Obesity.

    Science.gov (United States)

    Saunders, Katherine H; Igel, Leon I; Saumoy, Monica; Sharaiha, Reem Z; Aronne, Louis J

    2018-04-17

    In this review, we describe the FDA-approved and investigational devices and endoscopic bariatric therapies for the treatment of obesity. We focus on literature published in the past few years and present mechanisms of action as well as efficacy and safety data. Devices and endoscopic procedures are emerging options to fill the significant treatment gap in the management of obesity. Not only are these devices and procedures minimally invasive and reversible, but they are potentially more effective than antiobesity medications, often safer for poor surgical candidates and possibly less expensive than bariatric surgery. As many patients require a variety of management strategies (medications, devices, procedures, and/or surgery) in addition to lifestyle modifications to achieve clinically significant weight loss, the future of obesity treatment involves a multidisciplinary approach. Combinations of advanced treatment strategies can lead to additive or synergistic weight loss. This is an area that requires further investigation.

  14. [Thymus surgery in a general surgery department].

    Science.gov (United States)

    Mega, Raquel; Coelho, Fátima; Pimentel, Teresa; Ribero, Rui; Matos, Novo de; Araújo, António

    2005-01-01

    Evaluation of thymectomy cases between 1990-2003, in a General Surgery Department. Evaluation of the therapeutic efficacy in Miastenia Gravis patients. Retrospective study based on evaluation of data from Serviço de Cirurgia, Neurologia and Consult de Neurology processes, between 1990-2003, of 15 patients submitted to total thymectomy. 15 patients, aged 17 to 72, 11 female and 4 male. Miastenia Gravis was the main indication for surgery, for uncontrollable symptoms or suspicion of thymoma. In patients with myasthenia, surgery was accomplish after compensation of symptoms. There weren't post-surgery complications. Pathology were divided in thymic hyperplasia and thymoma. Miastenia patients have there symptoms diminished or stable with reduction or cessation of medical therapy. Miastenia was the most frequent indication for thymectomy. Surgery was good results, with low morbimortality, as long as the protocols are respected.

  15. Report of panel 1: The appropriate scope and mission of ITER

    Energy Technology Data Exchange (ETDEWEB)

    Linford, R.K. (Los Alamos National Lab., NM (United States)); Weitzner, H.; Abdou, M.A.; Baldwin, D.E.; Berkner, K.H.; Berry, L.A.; Culler, F.L.; Dean, S.O.; DeFreece, D.A.; Gauster, W.B. (and others)

    1992-12-01

    This panel looked at the mission of ITER, and how the US should address the present plans, and considers a number of alternative plans to arrive at the eventual goals of ITER. The panel considered three major approaches which have been discussed on the international scale, and tries to present the strengths, weaknesses, and possible changes to these plans. It suggests that any of these plans can arrive at the eventual aim, but may involve differing risks and time commitments. All plans involve ITER design studies, development work on technologies which must be in place for ITER design to succeed, and testing of materials and components for application in the device.

  16. Report of panel 1: The appropriate scope and mission of ITER

    International Nuclear Information System (INIS)

    Linford, R.K.; Weitzner, H.; Abdou, M.A.; Baldwin, D.E.; Berkner, K.H.; Berry, L.A.; Culler, F.L.; Dean, S.O.; DeFreece, D.A.; Gauster, W.B.

    1992-01-01

    This panel looked at the mission of ITER, and how the US should address the present plans, and considers a number of alternative plans to arrive at the eventual goals of ITER. The panel considered three major approaches which have been discussed on the international scale, and tries to present the strengths, weaknesses, and possible changes to these plans. It suggests that any of these plans can arrive at the eventual aim, but may involve differing risks and time commitments. All plans involve ITER design studies, development work on technologies which must be in place for ITER design to succeed, and testing of materials and components for application in the device

  17. PVT Panels. Fully renewable and competitive

    International Nuclear Information System (INIS)

    Bakker, M.; Strootman, K.J.; Jong, M.J.M.

    2003-10-01

    A photovoltaic/thermal (PVT) panel is a combination of photovoltaic cells with a solar thermal collector, generating solar electricity and solar heat simultaneously. PVT panels generate more solar energy per unit surface area than a combination of separate PV panels and solar thermal collectors, and share the aesthetic advantage of PV. After several years of research, PVT panels have been developed into a product that is now ready for market introduction. One of the most promising system concepts, consisting of 25 m 2 of PVT panels and a ground coupled heat pump, has been simulated in TRNSYS, and has been found to be able to fully cover both the building related electricity and heat consumption, while keeping the long-term average ground temperature constant. The cost and payback time of such a system have been determined; it has been found that the payback time of this system is approximately two-thirds of the payback time of an identical system but with 21 m 2 of PV panels and 4 m 2 of solar thermal collectors. Finally, by looking at the expected growth in the PV and solar thermal collector market, the market potential for for PVT panels has been found to be very large

  18. 21 CFR 874.3540 - Prosthesis modification instrument for ossicular replacement surgery.

    Science.gov (United States)

    2010-04-01

    ... replacement surgery. 874.3540 Section 874.3540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... § 874.3540 Prosthesis modification instrument for ossicular replacement surgery. (a) Identification. A prosthesis modification instrument for ossicular replacement surgery is a device intended for use by a...

  19. 76 FR 19147 - Aerospace Safety Advisory Panel; Meeting.

    Science.gov (United States)

    2011-04-06

    ... NATIONAL AERONAUTICS AND SPACE ADMINISTRATION [Notice (11-030)] Aerospace Safety Advisory Panel... Aeronautics and Space Administration announce a forthcoming meeting of the Aerospace Safety Advisory Panel.... Kathy Dakon, Aerospace Safety Advisory Panel Executive Director, National Aeronautics and Space...

  20. 76 FR 62455 - Aerospace Safety Advisory Panel; Meeting

    Science.gov (United States)

    2011-10-07

    ... NATIONAL AERONAUTICS AND SPACE ADMINISTRATION [Notice (11-088)] Aerospace Safety Advisory Panel... Aeronautics and Space Administration announces a forthcoming meeting of the Aerospace Safety Advisory Panel... Burch, Aerospace Safety Advisory Panel Administrative Officer, National Aeronautics and Space...

  1. 78 FR 56941 - Aerospace Safety Advisory Panel; Meeting

    Science.gov (United States)

    2013-09-16

    ... NATIONAL AERONAUTICS AND SPACE ADMINISTRATION [Notice: 13-114] Aerospace Safety Advisory Panel... Aeronautics and Space Administration announces a forthcoming meeting of the Aerospace Safety Advisory Panel.... Harmony Myers, Aerospace Safety Advisory Panel Executive Director, National Aeronautics and Space...

  2. 77 FR 25502 - Aerospace Safety Advisory Panel; Meeting

    Science.gov (United States)

    2012-04-30

    ... NATIONAL AERONAUTICS AND SPACE ADMINISTRATION [Notice (12-030)] Aerospace Safety Advisory Panel... Aeronautics and Space Administration announce a forthcoming meeting of the Aerospace Safety Advisory Panel... FURTHER INFORMATION CONTACT: Ms. Harmony Myers, Aerospace Safety Advisory Panel Executive Director...

  3. 77 FR 38090 - Aerospace Safety Advisory Panel; Meeting.

    Science.gov (United States)

    2012-06-26

    ... NATIONAL AERONAUTICS AND SPACE ADMINISTRATION [Notice 12-044] Aerospace Safety Advisory Panel... Aeronautics and Space Administration announces a forthcoming meeting of the Aerospace Safety Advisory Panel.... Harmony Myers, Aerospace Safety Advisory Panel Executive Director, National Aeronautics and Space...

  4. 78 FR 1265 - Aerospace Safety Advisory Panel; Meeting

    Science.gov (United States)

    2013-01-08

    ... NATIONAL AERONAUTICS AND SPACE ADMINISTRATION [Notice 13-001] Aerospace Safety Advisory Panel... Aeronautics and Space Administration announces a forthcoming meeting of the Aerospace Safety Advisory Panel..., Aerospace Safety Advisory Panel Executive Director, National Aeronautics and Space Administration...

  5. 75 FR 6407 - Aerospace Safety Advisory Panel; Meeting

    Science.gov (United States)

    2010-02-09

    ... NATIONAL AERONAUTICS AND SPACE ADMINISTRATION [Notice (10- 020)] Aerospace Safety Advisory Panel... Aeronautics and Space Administration announce a forthcoming meeting of the Aerospace Safety Advisory Panel... FURTHER INFORMATION CONTACT: Ms. Kathy Dakon, Aerospace Safety Advisory Panel Executive Director, National...

  6. 75 FR 61219 - Aerospace Safety Advisory Panel; Meeting

    Science.gov (United States)

    2010-10-04

    ... NATIONAL AERONAUTICS AND SPACE ADMINISTRATION [Notice (10-116)] Aerospace Safety Advisory Panel... Aeronautics and Space Administration announces a forthcoming meeting of the Aerospace Safety Advisory Panel... Dakon, Aerospace Safety Advisory Panel Executive Director, National Aeronautics and Space Administration...

  7. 77 FR 58413 - Aerospace Safety Advisory Panel; Meeting

    Science.gov (United States)

    2012-09-20

    ... NATIONAL AERONAUTICS AND SPACE ADMINISTRATION [Notice 12-074] Aerospace Safety Advisory Panel... Aeronautics and Space Administration announces a forthcoming meeting of the Aerospace Safety Advisory Panel.... Harmony Myers, Aerospace Safety Advisory Panel Executive Director, National Aeronautics and Space...

  8. Nutrition Following Pancreatic Surgery

    Science.gov (United States)

    ... BACK Contact Us DONATE NOW GENERAL DONATION PURPLESTRIDE Nutrition Following Pancreatic Surgery Home Facing Pancreatic Cancer Living with Pancreatic Cancer Diet and Nutrition Nutrition Following Pancreatic Surgery Ver esta página en ...

  9. Blood donation before surgery

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/patientinstructions/000367.htm Blood donation before surgery To use the sharing features on ... team. Related MedlinePlus Health Topics Blood Transfusion and Donation Surgery Browse the Encyclopedia A.D.A.M., ...

  10. Cosmetic ear surgery

    Science.gov (United States)

    Otoplasty; Ear pinning; Ear surgery - cosmetic; Ear reshaping; Pinnaplasty ... Cosmetic ear surgery may be done in the surgeon's office, an outpatient clinic, or a hospital. It can be performed under ...

  11. Open heart surgery

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002950.htm Open heart surgery To use the sharing features on this ... large arteries connected to the heart. The term "open heart surgery" means that you are connected to a ...

  12. Pediatric heart surgery - discharge

    Science.gov (United States)

    ... discharge; Heart valve surgery - children - discharge; Heart surgery - pediatric - discharge; Heart transplant - pediatric - discharge ... Geme JW, Schor NF, eds. Nelson Textbook of Pediatrics . 20th ed. Philadelphia, PA: Elsevier; 2016:chap 434. ...

  13. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... misalignment of jaws and teeth. Surgery can improve chewing, speaking and breathing. While the patient's appearance may ... indicate the need for corrective jaw surgery: Difficulty chewing, or biting food Difficulty swallowing Chronic jaw or ...

  14. Refractive corneal surgery - discharge

    Science.gov (United States)

    ... surgery. Avoid contact sports (such as boxing and football) for the first 4 weeks after surgery. DO ... herein should not be used during any medical emergency or for the diagnosis or treatment of any ...

  15. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... best performed by a trained surgeon with specialized education and training. Click here to find out more. ... more. Facial Cosmetic Surgery Facial Cosmetic Surgery Extensive education and training in surgical procedures involving skin, muscle, ...

  16. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... more surgeries depending on the extent of the repair needed. Click here to find out more. Corrective ... more surgeries depending on the extent of the repair needed. Click here to find out more. Corrective ...

  17. Surgery for pancreatic cancer

    Science.gov (United States)

    ... laparoscopically (using a tiny video camera) or using robotic surgery depends on: The extent of the surgery ... by URAC, also known as the American Accreditation HealthCare Commission (www.urac.org). URAC's accreditation program is ...

  18. Anti-reflux surgery

    Science.gov (United States)

    ... surgery. You may need another surgery in the future if you develop new reflux symptoms or swallowing ... Diseases of the esophagus. In: Goldman L, Schafer AI, eds. Goldman-Cecil Medicine . 25th ed. Philadelphia, PA: ...

  19. Blepharoplasty (Eyelid Surgery)

    Science.gov (United States)

    ... Blepharoplasty (BLEF-uh-roe-plas-tee) is a type of surgery that repairs droopy eyelids and may involve ... tobacco and drugs. Your expectations. An honest discussion of your hopes and motivation for surgery will help set the stage for ...

  20. Smoking and surgery

    Science.gov (United States)

    Surgery - quitting smoking; Surgery - quitting tobacco; Wound healing - smoking ... Tar, nicotine, and other chemicals from smoking can increase your risk of many health problems. These include heart and blood vessel problems, such as: Blood clots and aneurysms in ...

  1. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... Jaw Surgery Download Download the ebook for further information Corrective jaw, or orthognathic surgery is performed by ... your treatment. Correction of Common Dentofacial Deformities ​ ​ The information provided here is not intended as a substitute ...

  2. Cosmetic breast surgery - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000273.htm Cosmetic breast surgery - discharge To use the sharing features on this page, please enable JavaScript. You had cosmetic breast surgery to change the size or shape ...

  3. Shoulder surgery - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000179.htm Shoulder surgery - discharge To use the sharing features on this page, please enable JavaScript. You had shoulder surgery to repair the tissues inside or around your ...

  4. Weight Loss Surgery

    Science.gov (United States)

    Weight loss surgery helps people with extreme obesity to lose weight. It may be an option if you cannot lose weight ... obesity. There are different types of weight loss surgery. They often limit the amount of food you ...

  5. Advantages of robotics in benign gynecologic surgery.

    Science.gov (United States)

    Truong, Mireille; Kim, Jin Hee; Scheib, Stacey; Patzkowsky, Kristin

    2016-08-01

    gynecologic surgery. Conclusions on the benefits and risks of robotic surgery should be made with caution given limited data, especially when compared with other routes. Route of surgery selection should take into consideration the surgeons' skill and comfort level that allows for the highest level of safety and efficiency. Ultimately, the robotic device is an additional minimally invasive surgical tool that can further the goal of minimizing laparotomy in gynecology.

  6. Robotic liver surgery

    Science.gov (United States)

    Leung, Universe

    2014-01-01

    Robotic surgery is an evolving technology that has been successfully applied to a number of surgical specialties, but its use in liver surgery has so far been limited. In this review article we discuss the challenges of minimally invasive liver surgery, the pros and cons of robotics, the evolution of medical robots, and the potentials in applying this technology to liver surgery. The current data in the literature are also presented. PMID:25392840

  7. Predicting panel scores by linguistic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Van den Besselaar, P.; Stout, L.; Gou, X

    2016-07-01

    In this paper we explore the use of text analysis for deriving quality indicators of project proposals. We do full text analysis of 3030 review reports. After term extraction, we aggregate the term occurrences to linguistic categories. Using thse linguistic categories as independent variables, we study how well these predict the grading by the review panels. Together, the different linguistic categories explain about 50% of the variance in the grading of the applications. The relative importance of the different linguistic categories inform us about the way the panels work. This can be used to develop altmetrics for the quality of the peer and panel review processes. (Author)

  8. Advanced Ultrasupercritical (AUSC) Tube Membrane Panel Development

    Energy Technology Data Exchange (ETDEWEB)

    Pschirer, James [Alstom Power Inc., Windsor, CT (United States); Burgess, Joshua [Alstom Power Inc., Windsor, CT (United States); Schrecengost, Robert [Alstom Power Inc., Windsor, CT (United States)

    2017-08-16

    Alstom Power Inc., a wholly owned subsidiary of the General Electric Company (GE), has completed the project “Advanced Ultrasupercritical (AUSC) Tube Membrane Panel Development” under U.S. Department of Energy (DOE) Award Number DE-FE0024076. This project was part of DOE’s Novel Crosscutting Research and Development to Support Advanced Energy Systems program. AUSC Tube Membrane Panel Development was a two and one half year project to develop and verify the manufacturability and serviceability of welded tube membrane panels made from high performance materials suitable for the AUSC steam cycles, defined as high pressure steam turbine inlet conditions of 700-760°C (1292-1400°F) and 24.5-35MPa (3500-5000psi). The difficulty of this challenge lies in the fact that the membrane-welded construction imposes demands on the materials that are unlike any that exist in other parts of the boiler. Tube membrane panels have been designed, fabricated, and installed in boilers for over 50 years with relatively favorable experience when fabricated from carbon and Cr-Mo low alloy steels. The AUSC steam cycle requires membrane tube panels fabricated from materials that have not been used in a weldment with metal temperatures in the range of 582-610°C (1080-1130°F). Fabrication materials chosen for the tubing were Grade 92 and HR6W. Grade 92 is a creep strength enhanced ferritic Cr-Mo alloy and HR6W is a high nickel alloy. Once the materials were chosen, GE performed the engineering design of the panels, prepared shop manufacturing drawings, and developed manufacturing and inspection plans. After the materials were purchased, GE manufactured and inspected the tube membrane panels, determined if post fabrication heat treatment of the tube membrane panels was needed, performed pre- and post-weld heat treatment on the Grade 92 panels, conducted final nondestructive inspection of any heat treated tube membrane panels, conducted destructive inspection of the completed tube

  9. Flat or curved thin optical display panel

    Science.gov (United States)

    Veligdan, J.T.

    1995-01-10

    An optical panel includes a plurality of waveguides stacked together, with each waveguide having a first end and an opposite second end. The first ends collectively define a first face, and the second ends collectively define a second face of the panel. The second face is disposed at an acute face angle relative to the waveguides to provide a panel which is relatively thin compared to the height of the second face. In an exemplary embodiment for use in a projection TV, the first face is substantially smaller in height than the second face and receives a TV image, with the second face defining a screen for viewing the image enlarged. 7 figures.

  10. KUALITAS AKUSTIK PANEL DINDING BERBAHAN BAKU JERAMI

    Directory of Open Access Journals (Sweden)

    Christina E. Mediastika

    2008-01-01

    Full Text Available A series of study to explore possibility in using paddy-straw as main material to construct cheap and high quality panels has been developed. Prior to this study, laboratory research to examine strength of compression and tensile of the panels have been conducted, which is showed a significant value for a non-structural panel. The compression is 15 N/mm2 and tensile averaged at 0,5 N/mm2 . In this study, acoustic properties of the panels is to be examined, i.e.: transmission loss (TL, absorption coefficient (, and reverberation time (RT60. The test showed TL of 10 dB and 16 dB,  of 0,4 and 0,8 and improve RT60 from 0,88 sec to 0,35 sec and 0,16 sec (500 Hz is used for reference. Abstract in Bahasa Indonesia: Ketersediaan panel pelapis dinding yang bersifat akustik dengan harga yang lebih terjangkau seperti yang terbuat dari bahan limbah sangatlah penting. Pada penelitian awal telah diselidiki penggunaan jerami sebagai bahan baku pembuatan panel akustik, sekaligus telah dilakukan pengujian terhadap kareakteristik struktural (uji desak dan lentur dari panel tersebut. Dari uji kekuatan struktural, panel memiliki kekuatan desak mencapai 15 N/mm2 dan kuat lentur reta-rata 0,5 N/mm2. Kekuatan ini dianggap mencukupi bagi panel non-struktural yang hanya bertugas untuk memikul beban sendiri. Oleh karena tujuan awal pembuatan panel adalah untuk kepentingan akustik, maka pada penelitian lanjutan, dilakukan uji laboratorium dan lapangan untuk melihat karakterisktik akustiknya. Adapun pengujian meliputi: redaman/insulasi (TL, koefisien serap ( dan waktu dengung (RT60. Dari hasil pengujian, panel mempunyai TL 10 dB dan 16 dB,  0,4 dan 0,8, serta mampu memperbaiki RT60 ruangan dari 0,88 detik menjadi 0,35 detik dan 0,16 detik. Kesemua pengujian menggunakan band frekuensi 500 Hz sebagai acuan. Kata kunci: panel jerami, insulasi, koefisien serap, waktu dengung.

  11. Differing professional opinions: 1987 Special Review Panel

    International Nuclear Information System (INIS)

    1987-11-01

    In mid-1987, the Executive Director for Operations of the US Nuclear Regulatory Commission appointed a Special Review Panel to review the existing NRC policy for expressing differing professional views and to recommend possible improvements to the policy, if warranted. Through its own efforts and those of three subpanels and three consultants, the Panel developed recommendations for changes and improvements in five major areas. This report presents those recommendations, along with a detailed explanation of the Panel's findings, copies of the reports of the subpanels and consultants, and the results of a survey of NRC non-clerical employees on the issue

  12. Breast Cancer Surgery

    Science.gov (United States)

    FACTS FOR LIFE Breast Cancer Surgery The goal of breast cancer surgery is to remove the whole tumor from the breast. Some lymph nodes ... might still be in the body. Types of breast cancer surgery There are two types of breast cancer ...

  13. Corrective Jaw Surgery

    Medline Plus

    Full Text Available ... their surgery, orthognathic surgery is performed to correct functional problems. Jaw Surgery can have a dramatic effect on many aspects of life. Following are some of the conditions that may ... front, or side Facial injury Birth defects Receding lower jaw and ...

  14. Pediatric heart surgery

    Science.gov (United States)

    Heart surgery - pediatric; Heart surgery for children; Acquired heart disease; Heart valve surgery - children ... There are many kinds of heart defects. Some are minor, and others are more serious. Defects can occur inside the heart or in the large blood vessels ...

  15. 77 FR 125 - Draft Guidance for Industry and Food and Drug Administration Staff; Medical Device Classification...

    Science.gov (United States)

    2012-01-03

    ... organization. These 16 Panels have largely been the driving force for CDRH's internal organizational structure...). The draft guidance, when finalized, will represent the Agency's current thinking on medical device...

  16. 78 FR 21612 - Medical Device Classification Product Codes; Guidance for Industry and Food and Drug...

    Science.gov (United States)

    2013-04-11

    ... driving force for CDRH's internal organizational structure as well. These Panels were established with the... guidance represents the Agency's current thinking on medical device classification product codes. It does...

  17. Damping device

    International Nuclear Information System (INIS)

    Banks, E.L. Jr.; Dowell, T.P.

    1976-01-01

    The description is given of a damper which includes a pair of telescopic components interconnected by relative linear movement one in relation to the other, by a screw and ball nut device, with a braking surface on one of the components, a brake engaging the braking surface, an inertia mass entrained by the other components, non-deformable and distinct brake actuating gear, independently mobile in relation to the other braking system and fixed and controlled by the inertia mass, positively to engage the braking surface. This damper is for retaining the parts of a nuclear power station so that can withstand earthquakes [fr

  18. Thermonuclear device

    International Nuclear Information System (INIS)

    Inoue, Toyokazu; Murata, Toru.

    1983-01-01

    Purpose: To shield superconducting coils for use in the generation of magnetic field against neutron irradiation thereby preventing tritium contamination. Constitution: The thermonuclear device comprises, in its inside, a vacuum container for containing plasmas, superconducting coils disposed to the outside of the vacuum container and neutron absorbers disposed between the super-conducting coils and the vacuum container. since neutrons issued from the plasma are absorbed by neutron absorbers and not irradiated to the superconducting coils, generation of tritium due to the reaction between 3 He in the liquid helium as the coolants for the super-conducting coils and the neutrons is prevented. (Aizawa, K.)

  19. Strainer device

    International Nuclear Information System (INIS)

    Mokuya, Kenji.

    1975-01-01

    Object: To provide a strainer device, which is adapted to facilitate flushing and is particularly suited for installation in the cooling system of a liquid metal cooled fast breeding reactor. Structure: A casing accommodating a strainer and a blind plate for the selection of a flow path is provided at a suitable portion of the duct line. The blind plate is adapted to be rotated by an opening and closing means consisting of a rod. bellows, shaft and so forth. At the time of flushing, the duct line is sealed by the blind plate. (Nakamura, S.)

  20. SRV-automatic handling device

    International Nuclear Information System (INIS)

    Yamada, Koji

    1987-01-01

    Automatic handling device for the steam relief valves (SRV's) is developed in order to achieve a decrease in exposure of workers, increase in availability factor, improvement in reliability, improvement in safety of operation, and labor saving. A survey is made during a periodical inspection to examine the actual SVR handling operation. An SRV automatic handling device consists of four components: conveyor, armed conveyor, lifting machine, and control/monitoring system. The conveyor is so designed that the existing I-rail installed in the containment vessel can be used without any modification. This is employed for conveying an SRV along the rail. The armed conveyor, designed for a box rail, is used for an SRV installed away from the rail. By using the lifting machine, an SRV installed away from the I-rail is brought to a spot just below the rail so that the SRV can be transferred by the conveyor. The control/monitoring system consists of a control computer, operation panel, TV monitor and annunciator. The SRV handling device is operated by remote control from a control room. A trial equipment is constructed and performance/function testing is carried out using actual SRV's. As a result, is it shown that the SRV handling device requires only two operators to serve satisfactorily. The required time for removal and replacement of one SRV is about 10 minutes. (Nogami, K.)